Sample records for bowen ratio station

  1. Energy Balance Bowen Ratio Station (EBBR) Handbook

    SciTech Connect (OSTI)

    Cook, DR

    2011-02-23T23:59:59.000Z

    The energy balance Bowen ratio (EBBR) system produces 30-minute estimates of the vertical fluxes of sensible and latent heat at the local surface. Flux estimates are calculated from observations of net radiation, soil surface heat flux, and the vertical gradients of temperature and relative humidity (RH). Meteorological data collected by the EBBR are used to calculate bulk aerodynamic fluxes, which are used in the Bulk Aerodynamic Technique (BA) EBBR value-added product (VAP) to replace sunrise and sunset spikes in the flux data. A unique aspect of the system is the automatic exchange mechanism (AEM), which helps to reduce errors from instrument offset drift.

  2. ARM Energy Balance Bowen Ratio (EBBR) station: surf. heat flux and related data, 30-min

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Cook, David

    The Energy Balance Bowen Ratio (EBBR) system produces 30-min estimates of the vertical fluxes of sensible and latent heat at the local surface. Flux estimates are calculated from observations of net radiation, soil surface heat flux, and the vertical gradients of temperature and relative humidity. Meteorological data collected by the EBBR are used to calculate bulk aerodynamic fluxes, which are used in the Bulk Aerodynamic Technique (BA) EBBR value-added product (VAP) to replace sunrise and sunset spikes in the flux data. A unique aspect of the system is the automatic exchange mechanism (AEM), which helps to reduce errors from instrument offset drift.

  3. Condensate polishing at Plant Bowen

    SciTech Connect (OSTI)

    Friedman, K.A.; Siegwarth, D.P.; Sawochka, S.G.; McNea, D.A.; Suhonen, C.H.

    1984-02-01T23:59:59.000Z

    Condensate polisher system design and operation were evaluated at the fosssil-fueled Plant Bowen of Georgia Power Company relative to the ability of the polishers to achieve an effluent chemical quality consistent with PWR Steam Generator Owners Group Chemistry Guidelines. Polishers regenerated employing the Seprex and Ammonex processes were evaluated during normal plant operation and during periods of simulated condenser inleakage. Although polisher effluent quality was acceptable relative to boiler corrosion control at Plant Bowen, it was inconsistent with that required for recirculating PWR steam generators. Polisher effluent quality was reasonably consistent with requirements for PWR once-through steam generator systems. High polisher cation to anion resin equivalence ratios (3.4 to 1), and insufficiently rapid anion resin kinetics were the major reasons for the observed non-optimum polisher performance.

  4. Energy Balance Bowen Ratio System

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField Campaign:INEAWaterCool Roofs Energy 101: CoolServices »0 Energy Balance

  5. Office of Campus Activities 401 Bowen-Thompson Student Union

    E-Print Network [OSTI]

    Moore, Paul A.

    Office of Campus Activities 401 Bowen-Thompson Student Union Bowling Green, OH 43403 Phone (419 be submitted to the Office of Campus Activities, 401 Bowen- Thompson Student Union. Organizations

  6. A Review of "Christopher Plantin and Engraved Book Illustrations in Sixteenth-Century Europe" by Karen Bowen and Dirk Imhof

    E-Print Network [OSTI]

    Silver, Larry

    2010-01-01T23:59:59.000Z

    and thorough, this is a distinguished and rewarding contribu- tion to the history of higher education. Karen Bowen and Dirk Imhof. Christopher Plantin and Engraved Book Illustrations in Sixteenth-Century Europe. Cambridge: Cambridge University Press, 2008...

  7. he stable-hydrogen isotope ratio (D/H or 2H/1H, conventionally expressed as

    E-Print Network [OSTI]

    Green, Andy J.

    T he stable-hydrogen isotope ratio (D/H or 2H/1H, conventionally expressed as D) in bird feathers; Bowen et al. 2005; Votier et al. 2009). Because hydrogen in consumer tissues can ultimately be traced feathers (showing stable-hydrogen isotope characteristics typical of Siberia) and first-winter feathers

  8. An Overview of the Bowen Survey; detecting donor star signatures in Low Mass X-ray Binaries

    E-Print Network [OSTI]

    Remon Cornelisse; Jorge Casares; Teo Munoz-Darias; Danny Steeghs; Phil Charles; Rob Hynes; Kieran O'Brien

    2008-01-22T23:59:59.000Z

    In this paper we give a review of the Bowen fluorescence survey, showing that narrow emission lines (mainly NIII and CIII lines between 4630 and 4660 A) appear to be universally present in the Bowen blend of optically bright low mass X-ray binaries. These narrow lines are attributed to reprocessing in the companion star giving the first estimates of K_2, and thereby providing the first constraints on their system parameters. We will give an overview of the constraints on the masses of the compact objects and briefly highlight the most important results of the survey. Furthermore, we will point out the most promising systems for future follow-up studies and indicate how we think their estimates of the component masses can be improved.

  9. LANSCE | Materials Test Station

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Research Facility Training Office Contact Administrative nav background Materials Test Station dotline Testing New Reactor Fuels that Reduce Radioactive Waste Mission Used...

  10. Skate Station UF Services

    E-Print Network [OSTI]

    Pilyugin, Sergei S.

    friends, practice your English, and try new activities! Where: Skate Station Funworks We will be meeting and more orderly manner. Everyone will be served eventually. Fire Drills/Alarms: Whenever you hear a fire should park your bike in well-lighted areas and lock it up when you park it. The best lock is a U

  11. Hydrogen Filling Station

    SciTech Connect (OSTI)

    Boehm, Robert F; Sabacky, Bruce; Anderson II, Everett B; Haberman, David; Al-Hassin, Mowafak; He, Xiaoming; Morriseau, Brian

    2010-02-24T23:59:59.000Z

    Hydrogen is an environmentally attractive transportation fuel that has the potential to displace fossil fuels. The Freedom CAR and Freedom FUEL initiatives emphasize the importance of hydrogen as a future transportation fuel. Presently, Las Vegas has one hydrogen fueling station powered by natural gas. However, the use of traditional sources of energy to produce hydrogen does not maximize the benefit. The hydrogen fueling station developed under this grant used electrolysis units and solar energy to produce hydrogen fuel. Water and electricity are furnished to the unit and the output is hydrogen and oxygen. Three vehicles were converted to utilize the hydrogen produced at the station. The vehicles were all equipped with different types of technologies. The vehicles were used in the day-to-day operation of the Las Vegas Valley Water District and monitoring was performed on efficiency, reliability and maintenance requirements. The research and demonstration utilized for the reconfiguration of these vehicles could lead to new technologies in vehicle development that could make hydrogen-fueled vehicles more cost effective, economical, efficient and more widely used. In order to advance the development of a hydrogen future in Southern Nevada, project partners recognized a need to bring various entities involved in hydrogen development and deployment together as a means of sharing knowledge and eliminating duplication of efforts. A road-mapping session was held in Las Vegas in June 2006. The Nevada State Energy Office, representatives from DOE, DOE contractors and LANL, NETL, NREL were present. Leadership from the National hydrogen Association Board of Directors also attended. As a result of this session, a roadmap for hydrogen development was created. This roadmap has the ability to become a tool for use by other road-mapping efforts in the hydrogen community. It could also become a standard template for other states or even countries to approach planning for a hydrogen future. Project partners also conducted a workshop on hydrogen safety and permitting. This provided an opportunity for the various permitting agencies and end users to gather to share experiences and knowledge. As a result of this workshop, the permitting process for the hydrogen filling station on the Las Vegas Valley Water District’s land was done more efficiently and those who would be responsible for the operation were better educated on the safety and reliability of hydrogen production and storage. The lessons learned in permitting the filling station and conducting this workshop provided a basis for future hydrogen projects in the region. Continuing efforts to increase the working pressure of electrolysis and efficiency have been pursued. Research was also performed on improving the cost, efficiency and durability of Proton Exchange Membrane (PEM) hydrogen technology. Research elements focused upon PEM membranes, electrodes/catalysts, membrane-electrode assemblies, seals, bipolar plates, utilization of renewable power, reliability issues, scale, and advanced conversion topics. Additionally, direct solar-to-hydrogen conversion research to demonstrate stable and efficient photoelectrochemistry (PEC) hydrogen production systems based on a number of optional concepts was performed. Candidate PEC concepts included technical obstacles such as inefficient photocatalysis, inadequate photocurrent due to non-optimal material band gap energies, rapid electron-hole recombination, reduced hole mobility and diminished operational lifetimes of surface materials exposed to electrolytes. Project Objective 1: Design, build, operate hydrogen filling station Project Objective 2: Perform research and development for utilizing solar technologies on the hydrogen filling station and convert two utility vehicles for use by the station operators Project Objective 3: Increase capacity of hydrogen filling station; add additional vehicle; conduct safety workshop; develop a roadmap for hydrogen development; accelerate the development of photovoltaic components Project Objective 4:

  12. Alternative Fueling Station Locator

    Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data Center Home PageStation LocationsGeneseeValleyPerformance

  13. Alternative Fueling Station Locator

    Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data Center Home PageStation LocationsGeneseeValleyPerformance

  14. Idaho_SheepStation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville PowerCherries 82981-1cnHigh School footballHydrogenIT |Hot Springs Site #0104Sheep Station Site

  15. Transit Infrastructure Finance Through Station Location Auctions

    E-Print Network [OSTI]

    Ian Carlton

    2009-01-01T23:59:59.000Z

    Numerous route and station options Strong real estate marketreal estate market Transit friendly constituents Numerous route and station options

  16. Wachs Cutter Tooling Station (4495)

    Broader source: Energy.gov (indexed) [DOE]

    purchase, build and install Wachs cutter tooling. The Wachs Cutter Tooling Station is similar to previously operated facility tooling and will utilize an existing hydraulic unit....

  17. Hydrogen vehicle fueling station

    SciTech Connect (OSTI)

    Daney, D.E.; Edeskuty, F.J.; Daugherty, M.A.; Prenger, F.C.; Hill, D.D.

    1995-09-01T23:59:59.000Z

    The authors describe a hydrogen vehicle fueling station that receives and stores hydrogen in liquid form and dispenses it either as a liquid or compressed gas. The economics that accrue from the favorable weight and volume advantages of liquid hydrogen support this concept both now and probably for some time to come. The model for liquid transfer to a 120-liter vehicle tank shows that transfer times under five minutes are feasible with pump-assisted transfer, or for pressure transfer with subcooling greater than 1 K. The model for compressed gas transfer shows that underfilling of nearly 30% can occur during rapid filling. Cooling the fill gas to 214 K completely eliminates underfilling.

  18. Multiple-Objective Metric for Placing Multiple Base Stations in Wireless Sensor Networks

    E-Print Network [OSTI]

    Liblit, Ben

    positioning in sensor networks based on directional antennas [6], but it addresses secure positioningMultiple-Objective Metric for Placing Multiple Base Stations in Wireless Sensor Networks Soo Kim in wireless sensor networks. First, the ratio of sensor nodes which can communicate with a base station via

  19. Fuel Station Procedure Applicability All

    E-Print Network [OSTI]

    Moore, Paul A.

    Fuel Station Procedure Applicability All Last Revised 11/20/12 Procedure Owner Andrew Grant agrant for the purchasing and distribution of fuel for vehicles owned by Bowling Green State University (BGSU). This centralization is important to ensure compliance for BGSU employees who use the centralized fuel station and fuel

  20. Hydrogen Refueling Station Costs in Shanghai

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Shaojun, Liu; Ogden, J; Jianxin, Ma

    2006-01-01T23:59:59.000Z

    04 Hydrogen Refueling Station Costs in Shanghai Jonathan X.Hydrogen Refueling Station Costs in Shanghai Jonathan X.voltage connections) Capital costs for this equipment must

  1. Hydrogen refueling station costs in Shanghai

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Shaojun, Liu; Ogden, Joan M; Jianxin, Ma

    2007-01-01T23:59:59.000Z

    Kingdom; 2004. [8] Amos W. Costs of storing and transportingcon- nections). Capital costs for this equipment must bein an analysis of station costs. Total station construction

  2. Station Footprint: Separation Distances, Storage Options, and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Station Footprint: Separation Distances, Storage Options, and Pre-Cooling Station Footprint: Separation Distances, Storage Options, and Pre-Cooling This presentation by Aaron...

  3. Stations; A Multimedia Performance for Eight Players

    E-Print Network [OSTI]

    Giracello, Robert Francis

    2010-01-01T23:59:59.000Z

    RIVERSIDE Stations; A Multimedia Performance for EightDISSERTATION Stations; A Multimedia Performance for Eightthe tragic drama in a multimedia theater environment. Table

  4. Energy Department Launches Alternative Fueling Station Locator...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Department Launches Alternative Fueling Station Locator App Energy Department Launches Alternative Fueling Station Locator App November 7, 2013 - 11:16am Addthis As part of...

  5. Hydrogen Refueling Station Costs in Shanghai

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Shaojun, Liu; Ogden, J; Jianxin, Ma

    2006-01-01T23:59:59.000Z

    Costs Annualized Investment Cost, 1000$/yr Total AnnualizedH2 Fueling Stations Investment Cost Cost ($/yr) OperatingH2 Fueling Stations Investment Cost Cost ($/kg) Operating

  6. Celilo Converter Station - October 2005

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Asbestos has been removed from the station. Old, noisy, maintenance-in- tensive air-cooling has been replaced with an effi - cient, closed loop water-cooled system. Chemical...

  7. Fission Product Ratios as Treaty Monitoring Discriminants

    SciTech Connect (OSTI)

    Miley, Harry S.; Bowyer, Ted W.; Greenwood, Lawrence R.; Arthur, Richard J.

    2008-05-15T23:59:59.000Z

    The International Monitoring System (IMS) of the Comprehensive Test Ban Treaty Organization (CTBTO) is currently under construction. The IMS is intended for monitoring of nuclear explosions. The radionuclide branch of the IMS monitors the atmosphere for short-lived radioisotopes indicative of a nuclear weapon test, and includes field collection and measurement stations, as well as laboratories to provide reanalysis of the most important samples and a quality control function. The Pacific Northwest National Laboratory in Richland, Washington hosts the United States IMS laboratory, with the designation “RL16.” Since acute reactor containment failures and chronic reactor leakage may also produce similar isotopes, it is tempting to compute ratios of detected isotopes to determine the relevance of an event to the treaty or agreement in question. In this paper we will note several shortcomings of simple isotopic ratios: (1) fractionation of different chemical species, (2) difficulty in comparing isotopes within a single element, (3) the effect of unknown decay times. While these shortcomings will be shown in the light of an aerosol sample, several of the problems extend to xenon isotopic ratios. The result of the difficulties listed above is that considerable human expertise will be required to convert a simple mathematical ratio into a criterion which will reliably categorize an event as ‘reactor’ or ‘weapon’.

  8. The decommodified security ratio

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    are currently experiencing: changing patterns of work, the phenom- enon she calls the "breakdown in the wage furthered by the work of the International Labour Office. In particular, the programme of researchThe decommodified security ratio: A tool for assessing European social protection systems Georges

  9. NOAA PMEL Station Chemistry Data

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Quinn, Patricia

    Submicron and supermicron samples are analyzed by ion chromatography for Cl-, NO3-, SO4-2, Na+, NH4+, K+, Mg2+, and Ca+2. The analysis of MSA-, Br-, and oxalate has been added to some stations. Samples also are analyzed for total mass by gravimetric analysis at 55 +/- 5% RH.

  10. Mobile Alternative Fueling Station Locator

    SciTech Connect (OSTI)

    Not Available

    2009-04-01T23:59:59.000Z

    The Department of Energy's Alternative Fueling Station Locator is available on-the-go via cell phones, BlackBerrys, or other personal handheld devices. The mobile locator allows users to find the five closest biodiesel, electricity, E85, hydrogen, natural gas, and propane fueling sites using Google technology.

  11. LIQUIDSLIQUIDS GISAXSGISAXSGISAXS/WAXS station

    E-Print Network [OSTI]

    Ohta, Shigemi

    Beamline CapabilitiesBeamline Capabilities Sector 12-ID. Poster updated March 2014. #12;LIQUIDSLIQUIDS GISAXSGISAXSGISAXS/WAXS station: * Energy range: 2.1 to 24 keV * Low divergence mode: * Energy range: 6.5 to 24 keV * Beam focus:

  12. Multi-ratio transmission

    SciTech Connect (OSTI)

    Polak, J.C.

    1987-07-14T23:59:59.000Z

    A preselected multi-ratio power transmission is described comprising: input means for transmitting drive forces; output means; first, second and third friction clutch means each selectively engageable with the input means for accepting drive forces. First input gear means drivingly connects with the first friction clutch means; second input gear means drivingly connects with the second friction clutch means; third input gear means drivingly connects with the third clutch means; first output gear means drivingly connects with the first input gear means; second output gear means drivingly connects with the first and second input gear means; third output means drivingly connects between the third input gear means and the output means; and one double-acting synchronizer clutch for selectively engaging the first output gear means with the output means and alternately the second output gear means with the output means. The first friction clutch means and the one double-acting synchronizer clutch cooperates during engagement to establish two forward drive ratios between the input and output means. The second friction clutch means and the one double-acting synchronizer clutch cooperates during engagement to establish two other forward drive ratios between the input and output means. The third friction clutch means is engageable to provide another forward drive ratio between the input means and the output means; and the one double-acting synchronizer clutch is relieved of transmitting drive forces during the engagement of the third friction clutch means and being manipulable for alternate connection with either the first output gear or the second output gear while the third friction clutch means is engaged.

  13. ARM - Measurement - Isotope ratio

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625govInstrumentstdmadap Documentation TDMADAP : XDC documentationBarrow,ice particleSizegovMeasurementsIsotope ratio

  14. COMPARATIVE COSTS OF CALIFORNIA CENTRAL STATION ELECTRICITY

    E-Print Network [OSTI]

    Laughlin, Robert B.

    CALIFORNIA ENERGY COMMISSION COMPARATIVE COSTS OF CALIFORNIA CENTRAL STATION ELECTRICITY GENERATION and Anitha Rednam, Comparative Costs of California Central Station Electricity Generation Technologies................................................................................................... 1 CHAPTER 1: Summary of Technology Costs

  15. 7.1.1. Fernbahnhof / Rail Station

    E-Print Network [OSTI]

    Berlin,Technische Universität

    Fernbahnhofs 7.1.1.4.5 Kälteversorgung des Fernbahnhofs / Cooling Supply of Rail Station 7 Abwasserversorgung des Fernbahnhofs / Fresh and Used Water Supply of Rail Stations 7.1.1.4.1.1 Verfahren zur Fernbahnhofs 7.1.1.4.2 Stromversorgung des Fernbahnhofs / Power Supply of Rail Station 7

  16. Technical data HMS 760 X -36 stations

    E-Print Network [OSTI]

    Shoubridge, Eric

    water/rinse stations - 2 dry stations / or 2 pressure controlled DI stations - 60 slides per basket - 1. - Simultaneous multiple program execution for several programs. - Carriers for up to 2 slide baskets with 30 downwards ventilation flow and active charcoal filter. - Permanent program memory for more than 50 different

  17. RESEARCH ARTICLE 10.1002/2013WR014581

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    conducted using data from three regions (humid-arid) in the South Central United States as case studies is the linchpin to developing a greater understanding of the water and energy balance of a region. Limited networks of ET monitoring stations (e.g., weighing lysimeters, energy balance Bowen ratio systems, or eddy

  18. Dubuque generation station, Dubuque, Iowa

    SciTech Connect (OSTI)

    Peltier, R.

    2008-10-15T23:59:59.000Z

    Alliant Energy's Dubuque generation station is a fine example of why small does not mean insignificant in the power generation industry. This winner of the EUCG best performer award in the small plant category shows that its operating excellence towers over that of many larger and much newer coal-fired power plants. The plant has three operating units with boilers originally designed for Illinois basin coal but now Powder River Basin coal makes up 75% of the coal consumed. The boilers can also burn natural gas. 4 photos.

  19. Hanford Meteorological Station - Hanford Site

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOnItem NotEnergy,ARMFormsGasReleaseSpeechesHallNot Logged In You|DidYouKnowStation Hanford

  20. Performance Evaluation and Analysis Consortium End Station |...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    highlighting the "bucket" algorithm from UIUC. Credit: Leonid Oliker, Lawrence Berkeley National Laboratory Performance Evaluation and Analysis Consortium End Station PI Name:...

  1. Hydrogen refueling station costs in Shanghai

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Shaojun, Liu; Ogden, Joan M; Jianxin, Ma

    2007-01-01T23:59:59.000Z

    Fueling stations; Cost; Shanghai; Fuel cell vehicles 1.and the delivery cost for fuel cell vehicles, however, itthus hydrogen cost therefore depend on the ?eet of fuel cell

  2. Computational Optimization of Gas Compressor Stations: MINLP ...

    E-Print Network [OSTI]

    Daniel Rose

    2015-02-26T23:59:59.000Z

    Feb 26, 2015 ... Abstract: When considering cost-optimal operation of gas transport networks, compressor stations play the most important role. Proper ...

  3. Hydrogen refueling station costs in Shanghai

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Shaojun, Liu; Ogden, Joan M; Jianxin, Ma

    2007-01-01T23:59:59.000Z

    total installed capital cost (TIC) 1% Of TIC 25% Estimate ofcost estimates for six station types SMR 100 a Equipment capital

  4. Kansas Nuclear Profile - Wolf Creek Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    April 2012" "Next Release Date: February 2013" "Wolf Creek Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor...

  5. Washington Nuclear Profile - Columbia Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Columbia Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License expiration...

  6. Illinois Nuclear Profile - Dresden Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Dresden Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License expiration...

  7. Illinois Nuclear Profile - Clinton Power Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Clinton Power Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License expiration date"...

  8. Illinois Nuclear Profile - Byron Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Byron Generating Station" ,"Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License expiration date"...

  9. Massachusetts Nuclear Profile - Pilgrim Nuclear Power Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Pilgrim Nuclear Power Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer cpacity factor (percent)","Type","Commercial operation date","License...

  10. Illinois Nuclear Profile - Braidwood Generation Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Braidwood Generation Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License...

  11. Sandia National Laboratories: Reference Station Design

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and the National Renewable Energy Laboratory (NREL) announce the publication of two new Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) reports on...

  12. Sandia National Laboratories: hydrogen fueling station

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    station Widespread Hydrogen Fueling Infrastructure Is the Goal of H2FIRST Project On June 4, 2014, in Capabilities, Center for Infrastructure Research and Innovation (CIRI),...

  13. Hydrogen Fueling Infrastructure Research and Station Technology...

    Broader source: Energy.gov (indexed) [DOE]

    An Overview of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project" held on November 18, 2014. Hydrogen Fueling Infrastructure Research and...

  14. (Hydrogen) Service Stations 101 Steven M. Schlasner

    E-Print Network [OSTI]

    (Hydrogen) Service Stations 101 Steven M. Schlasner September 22, 2004 #12;2 DISCLAIMER Opinions · Comparison of Conventional with Hydrogen Fueling Stations · Hydrogen Fueling Life Cycle · Practical Design,000 retail outlets (350 company-owned) in 44 states · Brands: Conoco, Phillips 66, 76 · 32,800 miles pipeline

  15. LNG to CNG refueling stations

    SciTech Connect (OSTI)

    Branson, J.D. [ECOGAS Corp., Austin, TX (United States)

    1995-12-31T23:59:59.000Z

    While the fleet operator is concerned about the environment, he or she is going to make the choice based primarily on economics. Which fuel provides the lowest total operating cost? The calculation of this costing must include the price-per-gallon of the fuel delivered, as well as the tangible and intangible components of fuel delivery, such as downtime for vehicles during the refueling process, idle time for drivers during refueling, emissions costings resulting from compressor oil blow-by, inclusion of non-combustible constituents in the CNG, and energy consumption during the refueling process. Also, the upfront capital requirement of similar delivery capabilities must be compared. The use of LNG as the base resource for the delivered CNG, in conjunction with the utilization of a fully temperature-compressed LNG/CNG refueling system, eliminates many of the perceived shortfalls of CNG. An LNG/CNG refueling center designed to match the capabilities of the compressor-based station will have approximately the same initial capital requirement. However, because it derives its CNG sales product from the {minus}260 F LNG base product, thus availing itself of the natural physical properties of the cryogenic product, all other economic elements of the system favor the LNG/CNG product.

  16. Towards Matter-Antimatter Balance at RHIC Antiparticle-to-Particle Ratios measured with BRAHMS

    E-Print Network [OSTI]

    of energy used for particle production. Two collision scenarios limit the range of the baryon ratios (#22;p University, New York, New York 10003, 7 Niels Bohr Institute, University of Copenhagen, Denmark, 8 Texas A&M University, College Station,Texas 77843, 9 University of Bergen, Department of Physics, Bergen,Norway, 10

  17. Air pollution study of Laredo Customs Station

    E-Print Network [OSTI]

    Welling, Vidyadhar Yeshwant

    1972-01-01T23:59:59.000Z

    to the General Services Admin1stration for improv1ng the air quality at the Laredo Customs Station. The study includes investigation conducted on the site at the Station and at the Environmental Wind Tunnel Facilities located on the main campus of Texas A... the accuracy of the scaled model with that of the actual station a complete survey of veloc1ty, pressure, temperature and video tape recordings were taken in Laredo. These results were then compared with those simulated in the wind tunnel. Good correlation...

  18. High ratio recirculating gas compressor

    DOE Patents [OSTI]

    Weinbrecht, J.F.

    1989-08-22T23:59:59.000Z

    A high ratio positive displacement recirculating rotary compressor is disclosed. The compressor includes an integral heat exchanger and recirculation conduits for returning cooled, high pressure discharge gas to the compressor housing to reducing heating of the compressor and enable higher pressure ratios to be sustained. The compressor features a recirculation system which results in continuous and uninterrupted flow of recirculation gas to the compressor with no direct leakage to either the discharge port or the intake port of the compressor, resulting in a capability of higher sustained pressure ratios without overheating of the compressor. 10 figs.

  19. Sandia National Laboratories: More California Gas Stations Can...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Infrastructure Research and Innovation (CIRI)More California Gas Stations Can Provide Hydrogen than Previously Thought, Sandia Study Says More California Gas Stations Can Provide...

  20. air station north: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    quality monitoring station. Application to Physics Websites Summary: considered in the area of representativeness of differs from the station measurement by more than the given...

  1. Solution Methods for the Periodic Petrol Station Replenishment ...

    E-Print Network [OSTI]

    chefi

    2013-03-11T23:59:59.000Z

    The problem of planning petrol delivery to the distribution stations is well recognized in the Operations Research literature under the name of Petrol Station ...

  2. Alternative Fueling Station Locator App Provides Info at Your...

    Broader source: Energy.gov (indexed) [DOE]

    iPhone app helps you find fueling stations that offer electricity, natural gas, biodiesel, E85, propane, or hydrogen. | Energy Department The Alternative Fueling Station...

  3. Fuel Station of the Future- Innovative Approach to Fuel Cell...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Station of the Future- Innovative Approach to Fuel Cell Technology Unveiled in California Fuel Station of the Future- Innovative Approach to Fuel Cell Technology Unveiled in...

  4. Pdc - The Worldwide Leader in Hydrogen Refueling Station Compression...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Pdc - The Worldwide Leader in Hydrogen Refueling Station Compression Pdc - The Worldwide Leader in Hydrogen Refueling Station Compression This presentation by Matther Weaver of Pdc...

  5. Hydrogen Fueling Station in Honolulu, Hawaii Feasibility Analysis...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Fueling Station in Honolulu, Hawaii Feasibility Analysis Hydrogen Fueling Station in Honolulu, Hawaii Feasibility Analysis This feasibility report assesses the technical and...

  6. COMPARATIVE COSTS OF CALIFORNIA CENTRAL STATION ELECTRICITY

    E-Print Network [OSTI]

    CALIFORNIA ENERGY COMMISSION COMPARATIVE COSTS OF CALIFORNIA CENTRAL STATION ELECTRICITY GENERATIONCann Please use the following citation for this report: Klein, Joel. 2009. Comparative Costs of California............................................................................................................................1 Changes in the Cost of Generation Model

  7. CASE CRITICAL The Navajo Generating Station

    E-Print Network [OSTI]

    Hall, Sharon J.

    Republic The Navajo Generating Station, the largest coal-fired power plant in the West, provides electrical-old plant, Arizona's largest single source of carbon pollution, needs to update its pollution controls. Join

  8. Hydrogen Refueling Station Costs in Shanghai

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Shaojun, Liu; Ogden, J; Jianxin, Ma

    2006-01-01T23:59:59.000Z

    and the delivery cost for fuel cell vehicles, however, itfueling stations, cost, Shanghai, fuel cell vehicles 1.0hydrogen cost therefore depend on the fleet of fuel cell

  9. The College Station Residential Energy Compliance Code

    E-Print Network [OSTI]

    Claridge, D. E.; Schrock, D.

    1988-01-01T23:59:59.000Z

    The City of College Station, Texas adopted a new residential Energy Compliance Code in January, 1988. The code, which strengthens compliance requirements in several areas, has received broadly based support and acceptance from all major constituent...

  10. Repowering of the Midland Nuclear Station 

    E-Print Network [OSTI]

    Gatlin, C. E. Jr.; Vellender, G. C.; Mooney, J. A.

    1988-01-01T23:59:59.000Z

    The conversion of the Midland Nuclear Station to a combined cycle power facility is the first of its kind. The existing nuclear steam turbine, combined with new, natural-gas-fired gas turbines, will create the largest cogeneration facility...

  11. CHARGING STATION FOR ELECTRIC VEHICLES GREEN PARKING

    E-Print Network [OSTI]

    Vellend, Mark

    CHARGING STATION FOR ELECTRIC VEHICLES P 3 P 3 P 6 GREEN PARKING UNIVERSITÉ DE SHERBROOKE YELLOW (CAR-POOLING) PERMITS HOSPITAL PARKING PARKING-PERMIT DISPENSERS RESERVED DISABLED PARKING PLACES ONE

  12. Hydrogen Refueling Station Costs in Shanghai

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Shaojun, Liu; Ogden, Joan M; Jianxin, Ma

    2006-01-01T23:59:59.000Z

    Well-to-wheels analysis of hydrogen based fuel-cell vehicleJP, et al. Distributed Hydrogen Fueling Systems Analysis,”Year 2006 UCD—ITS—RR—06—04 Hydrogen Refueling Station Costs

  13. Hydrogen Fueling Infrastructure Research and Station Technology

    Broader source: Energy.gov [DOE]

    Presentation slides from the DOE Fuel Cell Technologies Office webinar "An Overview of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project" held on November 18, 2014.

  14. Solar and Infrared Radiation Station (SIRS) Handbook

    SciTech Connect (OSTI)

    Stoffel, T

    2005-07-01T23:59:59.000Z

    The Solar Infrared Radiation Station (SIRS) provides continuous measurements of broadband shortwave (solar) and longwave (atmospheric or infrared) irradiances for downwelling and upwelling components. The following six irradiance measurements are collected from a network of stations to help determine the total radiative flux exchange within the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Climate Research Facility: • Direct normal shortwave (solar beam) • Diffuse horizontal shortwave (sky) • Global horizontal shortwave (total hemispheric) • Upwelling shortwave (reflected) • Downwelling longwave (atmospheric infrared) • Upwelling longwave (surface infrared)

  15. An Assessment of the Near-Term Costs of Hydrogen Refueling Stations and Station Components

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Lipman, Timothy

    2006-01-01T23:59:59.000Z

    vs. delivered hydrogen, compressor type, storage pressure).pump High-pressure hydrogen compressor Compressed hydrogenpipeline High-pressure hydrogen compressor Pipeline Station:

  16. Hydrogen Fueling - Coming Soon to a Station Near You (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2009-04-01T23:59:59.000Z

    Fact sheet providing information useful to local permitting officials facing hydrogen fueling station proposals.

  17. Station Processing for a Low Frequency Array in WA

    E-Print Network [OSTI]

    Ellingson, Steven W.

    for the remote station, minus 2 kW for cooling (considered "infrastructure"). #12;Station Processing Requirements stations (regardless of role as remote or core) (yes; remote stations can be "less" not "different") 2 (yes: 2-3 for core, 1 for remote) 6. Cost: TBD. (Prorated cost of ~US$500 per dual-pol element

  18. An Assessment of the Near-Term Costs of Hydrogen Refueling Stations and Station Components

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Lipman, Timothy

    2006-01-01T23:59:59.000Z

    station. H2Gen’s estimates for capital costs are also lowerestimates and show high variability (26%-117% of capital costs).capital costs of about $250,000. Existing hydrogen station cost analyses tend to under-estimate

  19. The Normal/Bloomington Amtrak passenger station

    SciTech Connect (OSTI)

    Francis, C.E. [Illinois State Univ., Normal, IL (United States)

    1995-11-01T23:59:59.000Z

    The new Normal/Bloomington, Illinois Amtrak railroad passenger station was completed in 1990. A number of energy conservation technologies have been combined to provide for efficient railroad operations, passenger comfort, and a pleasing atmosphere. Passive solar heating, shading, and the building`s thermal efficiency have substantially reduced the amount of energy required for space conditions. The use of daylighting high efficiency fluorescent and high pressure sodium lighting as well as electronic load management have reduced energy requirements for lighting more than 70%. A stand-alone PV system provides energy for a portion of the building`s electrical requirement. An average monthly output of 147 kWh accounts for approximately 7.5% of the total electrical load. Overall, this station requires less than 25% of the energy required by a recently built `typical` station of similar size in a similar climate.

  20. Hydrogen fueling station development and demonstration

    SciTech Connect (OSTI)

    Edeskuty, F.J.; Daney, D.; Daugherty, M.; Hill, D.; Prenger, F.C.

    1996-09-01T23:59:59.000Z

    This is the final report of a one-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). This project sought to develop and demonstrate a hydrogen fueling station for vehicles. Such stations are an essential infrastructural element in the practical application of hydrogen as vehicle fuel, and a number of issues such as safety, efficiency, design, and operating procedures can only be accurately addressed by a practical demonstration. Regardless of whether the vehicle is powered by an internal combustion engine or fuel cell, or whether the vehicle has a liquid or gaseous fuel tank, the fueling station is a critical technology that is the link between the local storage facility and the vehicle.

  1. Economic Analysis of Hydrogen Energy Station Concepts: Are "H 2E-Stations" a Key Link to a Hydrogen Fuel Cell Vehicle Infrastructure?

    E-Print Network [OSTI]

    Lipman, Timothy E.; Edwards, Jennifer L.; Kammen, Daniel M.

    2002-01-01T23:59:59.000Z

    in the analysis of hydrogen energy stations, additionalattractiveness of the hydrogen energy station scheme in bothECONOMIC ANALYSIS OF HYDROGEN ENERGY STATION CONCEPTS: ARE '

  2. Pump station for radioactive waste water

    DOE Patents [OSTI]

    Whitton, John P.; Klos, Dean M.; Carrara, Danny T.; Minno, John J.

    2003-11-18T23:59:59.000Z

    A pump station for transferring radioactive particle containing waste water, includes: (a.) an enclosed sump having a vertically elongated right frusto conical wall surface and a bottom surface and (b.) a submersible volute centrifugal pump having a horizontally rotating impeller and a volute exterior surface. The sump interior surface, the bottom surface and the volute exterior surface are made of stainless steel having a 30 Ra or finer surface finish. A 15 Ra finish has been found to be most cost effective. The pump station is used for transferring waste water, without accumulation of radioactive fines.

  3. Design of a photovoltaic central power station

    SciTech Connect (OSTI)

    Not Available

    1984-02-01T23:59:59.000Z

    Photovoltaic central power station designs have been developed for both high-efficiency flat-panel arrays and two-axis tracking concentrator arrays. Both designs are based on a site adjacent to the Saguaro Power Station of Arizona Public Service. The plants are 100 MW each, made of 5 MW subfields. The site specific designs allow detailed cost estimate for site preparation, installation, and engineering. These designs are summarized and cost estimates analyzed. Provided also are recommendations for future work to reduce system cost for each plant design.

  4. Tethered nuclear power for the Space Station

    SciTech Connect (OSTI)

    Bents, D.J.

    1985-01-01T23:59:59.000Z

    A nuclear space power system the SP-100 is being developed for future missions where large amounts of electrical power will be required. Although it is primarily intended for unmanned spacecraft, it can be adapted to a manned space platform by tethering it above the station through an electrical transmission line which isolates the reactor far away from the inhabited platform and conveys its power back to where it is needed. The transmission line, used in conjunction with an instrument rate shield, attenuates reactor radiation in the vicinity of the space station to less than one-one hundredth of the natural background which is already there. This combination of shielding and distance attenuation is less than one-tenth the mass of boom-mounted or onboard man-rated shields that are required when the reactor is mounted nearby. This paper describes how connection is made to the platform (configuration, operational requirements) and introduces a new element the coaxial transmission tube which enables efficient transmission of electrical power through long tethers in space. Design methodology for transmission tubes and tube arrays is discussed. An example conceptual design is presented that shows SP-100 at three power levels 100 kWe, 300 kWe, and 1000 kWe connected to space station via a 2 km HVDC transmission line/tether. Power system performance, mass, and radiation hazard are estimated with impacts on space station architecture and operation.

  5. City of College Station's Thermographic Mobile Scan

    E-Print Network [OSTI]

    Shear, C. K.

    1986-01-01T23:59:59.000Z

    During the first quarter of 1986, the City of College Station conducted a thermographic mobile scan of the entire city. A thermographic mobile scan is a process by which heat loss/heat gain data is accumulated by a vehicle traveling the city...

  6. TechnicalDesign Report, Second Target Station

    SciTech Connect (OSTI)

    Galambos, John D [ORNL; Anderson, David E [ORNL; Bechtol, D [HDR, Inc.; Bethea, Katie L [ORNL; Brown, N [Barge Waggoner Sumner & Cannon, Inc.; Carden, W. F. [Oak Ridge National Laboratory (ORNL); Chae, Steven M [ORNL; Clark, A. [Barge Waggoner Sumner & Cannon, Inc.; Counce, Deborah M [ORNL; Craft, K [Barge Waggoner Sumner & Cannon, Inc.; Crofford, Mark T [ORNL; Collins, Richard M [ORNL; Cousineau, Sarah M [ORNL; Curry, Douglas E [ORNL; Cutler, Roy I [ORNL; Dayton, Michael J [ORNL; Dean, Robert A [ORNL; Deibele, Craig E [ORNL; Doleans, Marc [ORNL; Dye, T. [HDR, Inc.; Eason, Bob H [ORNL; Eckroth, James A [ORNL; Fincrock, C [HDR, Inc.; Fritts, S. [Barge Waggoner Sumner & Cannon, Inc.; Gallmeier, Franz X [ORNL; Gawne, Ken R [ORNL; Hartman, Steven M [ORNL; Herwig, Kenneth W [ORNL; Hess, S. [HDR, Inc.; Holmes, Jeffrey A [ORNL; Horak, Charlie M [ORNL; Howell, Matthew P [ORNL; Iverson, Erik B [ORNL; Jacobs, Lorelei L [ORNL; Jones, Larry C [ORNL; Johnson, B. [HDR, Inc.; Johnson, S. [HDR, Inc.; Kasemir, Kay [ORNL; Kim, Sang-Ho [ORNL; Laughon, Gregory J [ORNL; Lu, W. [Oak Ridge National Laboratory (ORNL); Mahoney, Kelly L [ORNL; Mammosser, John [ORNL; McManamy, T. [McManamy Consulting, Inc.; Michilini, M. [HDR, Inc.; Middendorf, Mark E [ORNL; O'Neal, Ed [Oak Ridge National Laboratory (ORNL); Nemec, B. [Barge Waggoner Sumner & Cannon, Inc.; Peters, Roy Cecil [ORNL; Plum, Michael A [ORNL; Reagan, G. [Barge Waggoner Sumner & Cannon, Inc.; Remec, Igor [ORNL; Rennich, Mark J [ORNL; Riemer, Bernie [ORNL; Saethre, Robert B [ORNL; Schubert, James Phillip [ORNL; Shishlo, Andrei P [ORNL; Smith, C Craig [ORNL; Strong, William Herb [ORNL; Tallant, Kathie M [ORNL; Tennant, David Alan [ORNL; Thibadeau, Barbara M [ORNL; Trumble, S. [HDR, Inc.; Trotter, Steven M [ORNL; Wang, Z. [Institute of Modern Physics (IMP), Chinese Academy of Sciences; Webb, Steven B [ORNL; Williams, Derrick C [ORNL; White, Karen S [ORNL; Zhao, Jinkui [ORNL

    2015-01-01T23:59:59.000Z

    The Second Target Station (STS) is a proposed upgrade for SNS. It includes a doubling of the accelerator power and an additional instrument hall. The new instrument hall will recieve a 467 kW 10 Hz beam. The parameters and preliminary design aspects of the STS are presented for the accelerator, target systems, instrument hall, instruments and civil construction aspects.

  7. Michigan State University Agricultural Experiment Station

    E-Print Network [OSTI]

    Douches, David S.

    Michigan State University Agricultural Experiment Station In Cooperation with the Michigan Potato Industry Commission Michigan Potato Research Report 2005 Volume 37 #12;Funding: Fed. Grant/MPIC 2005 POTATO. Hammerschmidt and W. Kirk Departments of Crop and Soil Sciences and Plant Pathology Michigan State University

  8. MICHIGAN STATE UNIVERSITY AGRICULTURAL EXPERIMENT STATION

    E-Print Network [OSTI]

    Douches, David S.

    MICHIGAN STATE UNIVERSITY AGRICULTURAL EXPERIMENT STATION IN COOPERATION WITH THE MICHIGAN POTATO INDUSTRY COMMISSION 2004 Michigan Potato Research Report Volume 36 Left to Right: Ben Kudwa, MPIC; Caryn of Crop and Soil Sciences Michigan State University East Lansing, MI 48824 Cooperators: R.W. Chase, Ray

  9. MICHIGAN STATE UNIVERSITY AGRICULTURAL EXPERIMENT STATION

    E-Print Network [OSTI]

    Douches, David S.

    MICHIGAN STATE UNIVERSITY AGRICULTURAL EXPERIMENT STATION IN COOPERATION WITH THE MICHIGAN POTATO INDUSTRY COMMISSION MICHIGAN POTATO RESEARCH REPORT 2003 Volume 35 Click Here to Open the 2003 Potato Sciences and Plant Pathology Michigan State University East Lansing, MI 48824 INTRODUCTION Each year we

  10. Michigan State University Agricultural Experiment Station

    E-Print Network [OSTI]

    Douches, David S.

    Michigan State University Agricultural Experiment Station In Cooperation with the Michigan Potato Industry Commission Michigan Potato Research Report 2005 Volume 37 #12;2005 POTATO BREEDING AND GENETICS Department of Crop and Soil Sciences Michigan State University East Lansing, MI 48824 Cooperators: R.W. Chase

  11. MICHIGAN STATE UNIVERSITY AGRICULTURAL EXPERIMENT STATION

    E-Print Network [OSTI]

    Douches, David S.

    MICHIGAN STATE UNIVERSITY AGRICULTURAL EXPERIMENT STATION IN COOPERATION WITH THE MICHIGAN POTATO INDUSTRY COMMISSION MICHIGAN POTATO RESEARCH REPORT 2003 Volume 35 Click Here to Open the 2003 Potato, S. Cooper, L. Frank, J. Driscoll, and E. Estelle Department of Crop and Soil Sciences Michigan State

  12. MICHIGAN STATE UNIVERSITY AGRICULTURAL EXPERIMENT STATION

    E-Print Network [OSTI]

    Douches, David S.

    MICHIGAN STATE UNIVERSITY AGRICULTURAL EXPERIMENT STATION IN COOPERATION WITH THE MICHIGAN POTATO INDUSTRY COMMISSION 2004 Michigan Potato Research Report Volume 36 Left to Right: Ben Kudwa, MPIC; Caryn and W. Kirk Departments of Crop and Soil Sciences and Plant Pathology Michigan State University East

  13. TARGET STATION INFRASTRUCTURE THE CNGS EXPERIENCE

    E-Print Network [OSTI]

    McDonald, Kirk

    of Aluminum Water cooled Current: 150kA (horn) ­ 180 kA (reflector) Pulse duration 7ms #12;Key elements Remote handling Remote station for radiation survey in the target chamber #12;CNGS Target Area I per cooling circuit 2007 run radiation effects on ventilation system electronics broken flexible stripline

  14. TEST STATION SALE OF PERFORMANCE TESTED BULLS

    E-Print Network [OSTI]

    Tennessee, University of

    in the test had to meet minimum performance requirements. Those were: CREEP NON-CREEP Adj 205 day wt. 560 520AS-B428 U T BULL TEST STATION SALE OF PERFORMANCE TESTED BULLS THURSDAY, MARCH 8, 2012 12:00 NOON IN GREENEVILLE AND KNOXVILLE LIVESTOCK CENTER http://animalscience.ag.utk.edu/ (For video) #12;UT BULL TEST

  15. Recent developments in HVDC convertor station design

    SciTech Connect (OSTI)

    Carlsson, L.

    1984-08-01T23:59:59.000Z

    New requirements on HVDC convertor station performance have emerged during the past few years. The paper presents some of these requirements and shows how they have been met through equipment and system development. This development will result in a new generation of HVDC transmissions with still better performance than for the projects presently in operation.

  16. Envera Variable Compression Ratio Engine

    SciTech Connect (OSTI)

    Charles Mendler

    2011-03-15T23:59:59.000Z

    Aggressive engine downsizing, variable compression ratio and use of the Atkinson cycle are being combined to improve fuel economy by up to 40 percent relative to port fuel injected gasoline engines, while maintaining full engine power. Approach Engine downsizing is viewed by US and foreign automobile manufacturers as one of the best options for improving fuel economy. While this strategy has already demonstrated a degree of success, downsizing and fuel economy gains are currently limited. With new variable compression ratio technology however, the degree of engine downsizing and fuel economy improvement can be greatly increased. A small variable compression ratio (VCR) engine has the potential to return significantly higher vehicle fuel economy while also providing high power. Affordability and potential for near term commercialization are key attributes of the Envera VCR engine. VCR Technology To meet torque and power requirements, a smaller engine needs to do more work per stroke. This is typically accomplished by boosting the incoming charge with either a turbo or supercharger so that more energy is present in the cylinder per stroke to do the work. With current production engines the degree of engine boosting (which correlates to downsizing) is limited by detonation (combustion knock) at high boost levels. Additionally, the turbo or supercharger needs to be responsive and efficient while providing the needed boost. VCR technology eliminates the limitation of engine knock at high load levels by reducing compression ratio to {approx}9:1 (or whatever level is appropriate) when high boost pressures are needed. By reducing the compression ratio during high load demand periods there is increased volume in the cylinder at top dead center (TDC) which allows more charge (or energy) to be present in the cylinder without increasing the peak pressure. Cylinder pressure is thus kept below the level at which the engine would begin to knock. When loads on the engine are low the compression ratio can be raised (to as much as 18:1) providing high engine efficiency. It is important to recognize that for a well designed VCR engine cylinder pressure does not need to be higher than found in current production turbocharged engines. As such, there is no need for a stronger crankcase, bearings and other load bearing parts within the VCR engine. The Envera VCR mechanism uses an eccentric carrier approach to adjust engine compression ratio. The crankshaft main bearings are mounted in this eccentric carrier or 'crankshaft cradle' and pivoting the eccentric carrier 30 degrees adjusts compression ratio from 9:1 to 18:1. The eccentric carrier is made up of a casting that provides rigid support for the main bearings, and removable upper bearing caps. Oil feed to the main bearings transits through the bearing cap fastener sockets. The eccentric carrier design was chosen for its low cost and rigid support of the main bearings. A control shaft and connecting links are used to pivot the eccentric carrier. The control shaft mechanism features compression ratio lock-up at minimum and maximum compression ratio settings. The control shaft method of pivoting the eccentric carrier was selected due to its lock-up capability. The control shaft can be rotated by a hydraulic actuator or an electric motor. The engine shown in Figures 3 and 4 has a hydraulic actuator that was developed under the current program. In-line 4-cylinder engines are significantly less expensive than V engines because an entire cylinder head can be eliminated. The cost savings from eliminating cylinders and an entire cylinder head will notably offset the added cost of the VCR and supercharging. Replacing V6 and V8 engines with in-line VCR 4-cylinder engines will provide high fuel economy at low cost. Numerous enabling technologies exist which have the potential to increase engine efficiency. The greatest efficiency gains are realized when the right combination of advanced and new technologies are packaged together to provide the greatest gains at the least cost. Aggressive engine downsiz

  17. An Assessment of the Near-Term Costs of Hydrogen Refueling Stations and Station Components

    E-Print Network [OSTI]

    Lipman, T E; Weinert, Jonathan X.

    2006-01-01T23:59:59.000Z

    Installed Capital Figure 4-21: Cost Estimates for 1,000 kg/station. H2Gen’s estimates for capital costs are also lowerestimates and show high variability (26%-117% of capital costs).

  18. Aquatic impacts from operation of three midwestern nuclear power stations: Cooper Nuclear Station environmental appraisal report

    SciTech Connect (OSTI)

    Brice, J.R.

    1981-10-01T23:59:59.000Z

    Cooper Nuclear Station is located on the Nebraska side of the Missouri River in Nemaha County. The station utilizes a boiling water reactor and steam turbine generator to produce 778 MW (net) of electrical power. The cooling system is a once-through design that withdraws water from, and discharges to, the Missouri River. No significant adverse impacts to the biota of the Missouri River from the Cooper Nuclear Station discharge were detected. Localized effects in the vicinity of the discharge have been observed. These include changes in the diversity and productivity of phytoplankton, periphyton, and benthic invertebrates at certain times of the year. The station appears to entrain large numbers of catostomid larvae, but this loss is not reflected in the available commercial fisheries statistics. Large numbers of gizzard shad and freshwater drum are impinged annually by Cooper Nuclear Station, but neither of these species seem to be adversely affected. Bigmouth buffalo populations could potentially suffer losses, but as was the case with the other catostomids, commercial catches of bigmouth buffalo did not seem to be affected by station operation.

  19. Upcoming H2USA Workshop: Hydrogen Fueling Station Component Listings...

    Office of Environmental Management (EM)

    H2USA Workshop: Hydrogen Fueling Station Component Listings Upcoming H2USA Workshop: Hydrogen Fueling Station Component Listings April 21, 2015 - 1:04pm Addthis H2USA will host an...

  20. Which way is up : towards accessible wayfinding in transit stations

    E-Print Network [OSTI]

    Leven, Dalia (Dalia Beth)

    2006-01-01T23:59:59.000Z

    Passengers' most frequent interaction with a rail transit system is at its stations, which represent the beginning, the end and sometimes the middle of transit trips. The design of these stations can greatly affect a user's ...

  1. Nuclear Rocket Development Station at the Nevada Test Site |...

    Office of Environmental Management (EM)

    Rocket Development Station at the Nevada Test Site Nuclear Rocket Development Station at the Nevada Test Site During the 1950s, the United States launched a nuclear rocket program...

  2. Development of By-Pass Blending Station System

    E-Print Network [OSTI]

    Liu, M.; Barnes, D.; Bunz, K.; Rosenberry, N.

    2003-01-01T23:59:59.000Z

    A new building blending station system named by-pass blending station (BBS) has been developed to reduce building pump energy consumption in both district heating and cooling systems. Theoretical investigation demonstrated that the BBS can...

  3. Fact #816: February 10, 2014 Natural Gas Refueling Stations Grow...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    6: February 10, 2014 Natural Gas Refueling Stations Grow Over the Last Ten Years Fact 816: February 10, 2014 Natural Gas Refueling Stations Grow Over the Last Ten Years In 2003...

  4. air station project: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Dryer space Mladenoff, David 23 NOAA Pacific Marine Environmental Laboratory Ocean Climate Stations Project Environmental Sciences and Ecology Websites Summary:...

  5. Central Station DHC Phase 1 feasibility

    SciTech Connect (OSTI)

    Henderson, H.L.

    1992-03-01T23:59:59.000Z

    This project assisted a private real estate developer in technically assessing the feasibility of integrating a central DHC system into a proposed 72 acre area mixed-use Planned Development (Central Station) just south of the Chicago Central Business District (Loop). The technical assessment concluded that a district heating and cooling system for Central Station will be feasible, provided that a major anchor load can be connected to the system. The system conceived for the site employs a modular approach that adjusts production capacity to actual load growth. The design concept includes gas-fired boilers for heating, gas turbine driven chillers for base loading, electric motor driven chillers for peaking, steam turbines for peak power and back pressure operation, and chilled water storage. Energy will be supplied to the users in the form of steam or low temperature hot water for heating, and low temperature chilled water for cooling.

  6. Variable ratio regenerative braking device

    DOE Patents [OSTI]

    Hoppie, Lyle O. (Birmingham, MI)

    1981-12-15T23:59:59.000Z

    Disclosed is a regenerative braking device (10) for an automotive vehicle. The device includes an energy storage assembly (12) having a plurality of rubber rollers (26, 28) mounted for rotation between an input shaft (36) and an output shaft (42), clutches (38, 46) and brakes (40, 48) associated with each shaft, and a continuously variable transmission (22) connectable to a vehicle drivetrain and to the input and output shafts by the respective clutches. The rubber rollers are torsionally stressed to accumulate energy from the vehicle when the input shaft is clutched to the transmission while the brake on the output shaft is applied, and are torsionally relaxed to deliver energy to the vehicle when the output shaft is clutched to the transmission while the brake on the input shaft is applied. The transmission ratio is varied to control the rate of energy accumulation and delivery for a given rotational speed of the vehicle drivetrain.

  7. Weather-Corrected Performance Ratio

    SciTech Connect (OSTI)

    Dierauf, T.; Growitz, A.; Kurtz, S.; Cruz, J. L. B.; Riley, E.; Hansen, C.

    2013-04-01T23:59:59.000Z

    Photovoltaic (PV) system performance depends on both the quality of the system and the weather. One simple way to communicate the system performance is to use the performance ratio (PR): the ratio of the electricity generated to the electricity that would have been generated if the plant consistently converted sunlight to electricity at the level expected from the DC nameplate rating. The annual system yield for flat-plate PV systems is estimated by the product of the annual insolation in the plane of the array, the nameplate rating of the system, and the PR, which provides an attractive way to estimate expected annual system yield. Unfortunately, the PR is, again, a function of both the PV system efficiency and the weather. If the PR is measured during the winter or during the summer, substantially different values may be obtained, making this metric insufficient to use as the basis for a performance guarantee when precise confidence intervals are required. This technical report defines a way to modify the PR calculation to neutralize biases that may be introduced by variations in the weather, while still reporting a PR that reflects the annual PR at that site given the project design and the project weather file. This resulting weather-corrected PR gives more consistent results throughout the year, enabling its use as a metric for performance guarantees while still retaining the familiarity this metric brings to the industry and the value of its use in predicting actual annual system yield. A testing protocol is also presented to illustrate the use of this new metric with the intent of providing a reference starting point for contractual content.

  8. Improving Unit Operations-Test Station Performance

    E-Print Network [OSTI]

    Filak, J. J. Jr.

    IMPROVING UNIT OPERATIONS - TEST STATION PERFORMANCE JosqIb 1. Filak. Jr, ? Corporate Energy Manager. Park.er?Hannafin COfpontioo- Cleveland. Oh ABSTRACT: This program's basic concept deals with the possibilities for reducing energy efficiency... requirements, control operation test performance functions more successfully, and retain peak load surges from reaching higher utility rate expense levels. 142 ESL-IE-95-04-23 Proceedings from the Seventeenth Industrial Energy Technology Conference...

  9. Xcel Energy Comanche Station: Pueblo, Colorado (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Stoffel, T.; Andreas, A.

    A partnership with industry and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

  10. Small SDI battle stations - More is better

    SciTech Connect (OSTI)

    Cornet, E.

    1986-09-01T23:59:59.000Z

    It is presently suggested that large numbers of lower capability SDI systems, in contrast to small numbers of large battle stations, offer better overall defense performance at lower total cost, with lower technical risk, lower sensitivity to threat scenario variability, and improved survivability. This follows from such factors as the positioning of more platforms within effective range of targets during all phases of an attack, less exacting optics requirements, mass production economies-of-scale, and improved survivability.

  11. Manuel pour installer une station sismologique OSIRIS

    E-Print Network [OSTI]

    Perrot, Julie

    installation Tout d'abord, enterrer le sismom`etre, s'assurer de l'horizontalit´e du sismo c'est-`a-dire, bulle le c^able sur le sismo, v´erifier de nouveau l'horizontalit´e. GPS Batterie ` Station d "sismo" puis cd osiris puis ./nrtd -set eth0 #12;7- Lancer Firefox (web browser) depuis la barre de menu

  12. Plug-In Electric Vehicle Handbook for Public Charging Station Hosts (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2012-04-01T23:59:59.000Z

    This handbook answers basic questions about plug-in electric vehicles, charging stations, charging equipment, and considerations for station owners, property owners, and station hosts.

  13. Optimization of compression and storage requirements at hydrogen refueling stations.

    SciTech Connect (OSTI)

    Elgowainy, A.; Mintz, M.; Kelly, B.; Hooks, M.; Paster, M. (Energy Systems); (Nexant, Inc.); (TIAX LLC)

    2008-01-01T23:59:59.000Z

    The transition to hydrogen-powered vehicles requires detailed technical and economic analyses of all aspects of hydrogen infrastructure, including refueling stations. The cost of such stations is a major contributor to the delivered cost of hydrogen. Hydrogen refueling stations require not only dispensers to transfer fuel onto a vehicle, but also an array of such ancillary equipment as a cascade charging system, storage vessels, compressors and/or pumps/evaporators. This paper provides detailed information on design requirements for gaseous and liquid hydrogen refueling stations and their associated capital and operating costs, which in turn impact hydrogen selling price at various levels of hydrogen demand. It summarizes an engineering economics approach which captures the effect of variations in station size, seasonal, daily and hourly demand, and alternative dispensing rates and pressures on station cost. Tradeoffs in the capacity of refueling station compressors, storage vessels, and the cascade charging system result in many possible configurations for the station. Total costs can be minimized by optimizing that configuration. Using a methodology to iterate among the costs of compression, storage and cascade charging, it was found that the optimum hourly capacity of the compressor is approximately twice the station's average hourly demand, and the optimum capacity of the cascade charging system is approximately 15% of the station's average daily demand. Further, for an hourly demand profile typical of today's gasoline stations, onsite hydrogen storage equivalent to at least 1/3 of the station's average daily demand is needed to accommodate peak demand.

  14. Competitive Charging Station Pricing for Plug-in Electric Vehicles

    E-Print Network [OSTI]

    Huang, Jianwei

    . To overcome this challenge, we develop a low-complexity algorithm that efficiently computes the pricingCompetitive Charging Station Pricing for Plug-in Electric Vehicles Wei Yuan, Member, IEEE, Jianwei considers the problem of charging station pricing and station selection of plug-in electric vehicles (PEVs

  15. "Space Station" Theme: Learning to Work, and Live, in Space

    E-Print Network [OSTI]

    Mathis, Wayne N.

    "Space Station" IMAX Film Theme: Learning to Work, and Live, in Space The educational value of NASM visit and afterward. See the "Alignment with Standards" table for details regarding how "Space Station in the "Space Station" program: · How astronauts train · What it is like to live and work in Space aboard

  16. Antenna unit and radio base station therewith

    DOE Patents [OSTI]

    Kuwahara, Mikio; Doi, Nobukazu; Suzuki, Toshiro; Ishida, Yuji; Inoue, Takashi; Niida, Sumaru

    2007-04-10T23:59:59.000Z

    Phase and amplitude deviations, which are generated, for example, by cables connecting an array antenna of a CDMA base station and the base station, are calibrated in the baseband. The base station comprises: an antenna apparatus 1; couplers 2; an RF unit 3 that converts a receive signal to a baseband signal, converts a transmit signal to a radio frequency, and performs power control; an A/D converter 4 for converting a receive signal to a digital signal; a receive beam form unit 6 that multiplies the receive signal by semi-fixed weight; a despreader 7 for this signal input; a time-space demodulator 8 for demodulating user data; a despreader 9 for probe signal; a space modulator 14 for user data; a spreader 13 for user signal; a channel combiner 12; a Tx calibrater 11 for controlling calibration of a signal; a D/A converter 10; a unit 16 for calculation of correlation matrix for generating a probe signal used for controlling an Rx calibration system and a TX calibration system; a spreader 17 for probe signal; a power control unit 18; a D/A converter 19; an RF unit 20 for probe signal; an A/D converter 21 for signal from the couplers 2; and a despreader 22.

  17. Kansas City`s Union Station redevelopment opportunity -- Environmental challenges

    SciTech Connect (OSTI)

    Snyder, M.G. [Black and Veatch Waste Science, Inc., Overland Park, KS (United States); Scott, A. [Union Station Assistance Corp., Kansas City, MO (United States)

    1995-12-31T23:59:59.000Z

    Kansas City`s Union Station, located at the center of a 1.7 million metropolitan population, is the second largest train station in the United States. The Station ceased to operate as a train station in 1983 and has since been falling into an increasing state of disrepair. This paper provides an insight into ``brownfield`` redevelopment and renovation for adaptive reuse of major turn of the century facilities such as Union Station. Substantial assessment and investigation activities have been conducted at Union Station for compliance and corrective action under RCRA, TSCA, and associated state regulations encompassing remediation estimated at more than $3 million. Recognized environmental conditions identified at Union Station included potential underground storage tanks; solid wastes, special wastes, and potentially hazardous wastes located inside the building; free liquids in sumps and elevator pits; asbestos-containing materials; lead-based paint; and potential for soil contamination on the surrounding property.

  18. Repowering of the Midland Nuclear Station

    E-Print Network [OSTI]

    Gatlin, C. E. Jr.; Vellender, G. C.; Mooney, J. A.

    natural gas-fired cx:rnbined~cle plant ~~on utilized the original Midland Unit 1 steam turb~ am 12 gas t:w:bine heat recovery trains to prov de 1,165 MW of generatin;J capacity. 'Ihi.s ~ on included a staged approach to stagger availability of the ad... the largest cogeneration facility in the United States. The paper describes the project and the converted facility. 'Ibe Midland Cogeneration Plant started as a 2-unit nuclear-powered electric generating station supplyin;J cogenerated steam to an adjacent...

  19. Polk power station syngas cooling system

    SciTech Connect (OSTI)

    Jenkins, S.D.

    1995-01-01T23:59:59.000Z

    Tampa Electric Company (TEC) is in the site development and construction phase of the new Polk Power Station Unit No. 1. This will be the first unit at a new site and will use Integrated Gasification Combined Cycle (IGCC) Technology. The unit will utilize Texaco`s oxygen-blown, entrained-flow coal gasification, along with combined cycle power generation, to produce nominal 260MW. Integral to the gasification process is the syngas cooling system. The design, integration, fabrication, transportation, and erection of this equipment have provided and continue to provide major challenges for this project.

  20. Hellisheidi Geothermal Power Station | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are8COaBulkTransmissionSitingProcess.pdfGetec AG|InformationInformation Station - South Iceland Jump

  1. Schiller Station Biomass Facility | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to:Ezfeedflag JumpID-f < RAPID‎ |Rippey JumpAir Jump to: navigation,Delta Jump to:Station

  2. Early Station Costs Questionnaire | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny:RevisedAdvisory Board Contributions EMEMEnergyEarly Station Costs Questionnaire

  3. Tianlin Baxin Hydropower Station | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualProperty Edit withTianlin Baxin Hydropower Station Jump to: navigation, search Name: Tianlin

  4. Alternative Fuels Data Center: Hydrogen Fueling Stations

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625govInstrumentstdmadapInactiveVisiting the TWP TWP RelatedCellulase C.Tier 2NorthAvailabilityBasicsFueling Stations

  5. Rancia Geothermal Power Station | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro Industries Pvt Ltd Jump to: navigation, search Name:Rancia 2 Geothermal Power Station Jump

  6. Report on Experiments with Citrus Fruits at the Beeville Sub-station.

    E-Print Network [OSTI]

    Potts, A. T. (Arthur Tillman)

    1912-01-01T23:59:59.000Z

    !TEXAS AGRICULTURAL EXPERIMENT STATIONS BULLETIN No. 148. MAY, 1912. Report on Experiments With Citrus Fruits at The Bee- ville Sub-station A. T. POTTS, Superintendent Beeville Sub-station AUSTIN PRINTING COMPANY AUSTIN. TEXAS TEXAS... EXPERIMENT STATIONS. GOVERNING BOARD. 1 DIRECTOR OF STATIONS. ...................................... B. YOUNOBLOOD, M. S.. .College Station I SUPERINTENDENTS OF SUB-STATIONS. .................. E. E. BINFORD, Beeville Sub-station.. .Beeville, P:.e Cc...

  7. Cirrus cloud-temperature interactions over a tropical station, Gadanki from lidar and satellite observations

    SciTech Connect (OSTI)

    S, Motty G, E-mail: mottygs@gmail.com; Satyanarayana, M., E-mail: mottygs@gmail.com; Krishnakumar, V., E-mail: mottygs@gmail.com; Dhaman, Reji k., E-mail: mottygs@gmail.com [Department of Optoelectronics, University of Kerala, Kariavattom, Trivandrum-695 581, Kerala (India)

    2014-10-15T23:59:59.000Z

    The cirrus clouds play an important role in the radiation budget of the earth's atmospheric system and are important to characterize their vertical structure and optical properties. LIDAR measurements are obtained from the tropical station Gadanki (13.5{sup 0} N, 79.2{sup 0} E), India, and meteorological indicators derived from Radiosonde data. Most of the cirrus clouds are observed near to the tropopause, which substantiates the strength of the tropical convective processes. The height and temperature dependencies of cloud height, optical depth, and depolarization ratio were investigated. Cirrus observations made using CALIPSO satellite are compared with lidar data for systematic statistical study of cirrus climatology.

  8. The University of Wisconsin-Milwaukee Field Station The Field Station is celebrating its 50th

    E-Print Network [OSTI]

    Saldin, Dilano

    land, until today the Field Station has grown into an active, vibrant facility with many projects for experimental research. Growth of our facilities has been funded by the National Science Foundation Bat Hibernaculum, an abandoned iron mine in Dodge County that is one of the largest sites

  9. Effective Load Management for the City of College Station 

    E-Print Network [OSTI]

    Hecox, O. D.; Bauer, V.

    1985-01-01T23:59:59.000Z

    aspects a. Complete energy survey of all faci- lities whose utilities the city pays to Valerie Bauer Chairman College Station Energy Hanagement Committee College Station, TX establish load reduction possibilities. b. Sub-station load surveillance... for tech- nical assistance, resulting in Orlin D. Hecox assist- ing throughout the summer. Several meetings were arranged in June with city department heads to provide them with billing histories and meter sheets on their facilities and to outline...

  10. 20,000 and Counting: Alternative Fueling and Charging Stations...

    Broader source: Energy.gov (indexed) [DOE]

    gas, electricity, E85 (up to 85% ethanol), hydrogen, liquefied natural gas, and propane. The Station Locator offers drivers several ways to search for and sort information:...

  11. H2FIRST Reference Station Design Task: Project Deliverable 2...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    electric vehicle customers have a positive fueling experience relative to conventional gasolinediesel stations as vehicles are introduced (2015-2017) and transition to advanced...

  12. H2FIRST Reference Station Design Task: Project Deliverable 2...

    Broader source: Energy.gov (indexed) [DOE]

    layouts. This work presents the hydrogen community with a uniform, cost-optimal formula for designing and building hydrogen stations. The piping and instrumentation diagrams...

  13. Data report for the Northeast Residential Experiment Station, November 1981

    SciTech Connect (OSTI)

    Russell, M.C.; Raghuraman, P.; Mahoney, P.C.

    1981-12-01T23:59:59.000Z

    Physical performance data for the month of November 1981 obtained from photovoltaic energy systems under test at the Northeast Residential Experiment Station in Concord, Massachusetts are tabulated.

  14. Geothermal system saving money at fire station | Department of...

    Broader source: Energy.gov (indexed) [DOE]

    of the College Township municipal building earlier this year in State College, Pa., home to Pennsylvania State University. The station has rooms and amenities for live-in...

  15. New Jersey Nuclear Profile - PSEG Salem Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    PSEG Salem Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License...

  16. California Nuclear Profile - San Onofre Nuclear Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    San Onofre Nuclear Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License...

  17. New Jersey Nuclear Profile - PSEG Hope Creek Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    PSEG Hope Creek Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License...

  18. Illinois Nuclear Profile - LaSalle Generating Station

    U.S. Energy Information Administration (EIA) Indexed Site

    LaSalle Generating Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License expiration...

  19. New York Nuclear Profile - Nine Mile Point Nuclear Station

    U.S. Energy Information Administration (EIA) Indexed Site

    Nine Mile Point Nuclear Station" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License...

  20. Microgrid V2G Charging Station Interconnection Testing (Presentation)

    SciTech Connect (OSTI)

    Simpson, M.

    2013-07-01T23:59:59.000Z

    This presentation by Mike Simpson of the National Renewable Energy Laboratory (NREL) describes NREL's microgrid vehicle-to-grid charging station interconnection testing.

  1. anna power station: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    1 Regarding Kewaunee Power Station CiteSeer Summary: This supplemental environmental impact statement (SEIS) has been prepared in response to an application submitted by Dominion...

  2. anna power stations: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    1 Regarding Kewaunee Power Station CiteSeer Summary: This supplemental environmental impact statement (SEIS) has been prepared in response to an application submitted by Dominion...

  3. air station cape: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    :M. J. Evans :S. R. Arnold Institute for Climate & Atmospheric Science, School 137 OF CAR SHARING STATIONS CiteSeer Summary: Approximately half of the worlds population is...

  4. Re: Potomac River Generating Station Department of Energy Case...

    Energy Savers [EERE]

    PEPCO is providing you with information regarding the planned transmission maintenance outage Re: Potomac River Generating Station Department of Energy Case No. EO-05-01: PEPCO is...

  5. EIS-0478: Antelope Valley Station to Neset Transmission Project...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Mercer, Dunn, Billings, Williams, McKenzie, and Mountrail Counties, North Dakota EIS-0478: Antelope Valley Station to Neset Transmission Project, Mercer, Dunn, Billings,...

  6. Solar Powered Radioactive Air Monitoring Stations

    SciTech Connect (OSTI)

    Barnett, J. M.; Bisping, Lynn E.; Gervais, Todd L.

    2013-10-30T23:59:59.000Z

    Environmental monitoring of ambient air for radioactive material is required as stipulated in the PNNL Site radioactive air license. Sampling ambient air at identified preferred locations could not be initially accomplished because utilities were not readily available. Therefore, solar powered environmental monitoring systems were considered as a possible option. PNNL purchased two 24-V DC solar powered environmental monitoring systems which consisted of solar panels, battery banks, and sampling units. During an approximate four month performance evaluation period, the solar stations operated satisfactorily at an on-site test location. They were subsequently relocated to their preferred locations in June 2012 where they continue to function adequately under the conditions found in Richland, Washington.

  7. Condensate polishing at Surry Nuclear Power Station

    SciTech Connect (OSTI)

    McNea, D.A.; Siegwarth, D.P.; Friedman, K.A.; Sawochka, S.G.

    1983-06-01T23:59:59.000Z

    Condensate polisher system design and operation at the Surry Nuclear Power Station of Virginia Electric and Power Company were evaluated relative to the ability of the polishers to achieve effluent water quality consistent with PWR Steam Generator Owners Group chemistry guidelines. Polishers regenerated employing a conventional process were evaluated during normal plant operation and during periods of simulated condenser inleakage. Polisher effluent quality was consistent with requirements for PWR steam generator corrosion minimization with minor exceptions, i.e., sodium and sulfate leakage immediately following initiation of most service cycles. Resin aging and incomplete separation of anion and cation resin during the regeneration process were the major reasons for non-optimum polisher performance.

  8. Eccentric crank variable compression ratio mechanism

    DOE Patents [OSTI]

    Lawrence, Keith Edward (Kobe, JP); Moser, William Elliott (Peoria, IL); Roozenboom, Stephan Donald (Washington, IL); Knox, Kevin Jay (Peoria, IL)

    2008-05-13T23:59:59.000Z

    A variable compression ratio mechanism for an internal combustion engine that has an engine block and a crankshaft is disclosed. The variable compression ratio mechanism has a plurality of eccentric disks configured to support the crankshaft. Each of the plurality of eccentric disks has at least one cylindrical portion annularly surrounded by the engine block. The variable compression ratio mechanism also has at least one actuator configured to rotate the plurality of eccentric disks.

  9. Abundance Ratios in Early-Type Galaxies

    E-Print Network [OSTI]

    Reynier Peletier

    1999-04-21T23:59:59.000Z

    Although evidence is accumulating that abundance ratios in galaxies are often non-solar, they are far from understood. I resume the current evidence for non-solar abundance ratios, supplementing the recent review by Worthey (1998) with some new results. It appears that the Mg/Fe abundance ratio only depends on the mass of the galaxy, not on the formation time-scale. For massive galaxies [Mg/Fe] > 0, while small galaxies show solar abundance ratios. Information about abundances of other element is scarce, but new evidence is given that [Ca/Fe] is solar, or slightly lower than solar, contrary to what is expected for an alpha-element.

  10. Aquatic Chemistry, CEGR 6090 Fall 1999, Bowen

    E-Print Network [OSTI]

    Bowen, James D.

    defined by: a. [CO2]T = 10-2 M and [KCl]T = 10-2 M b. [H2S]T = 10-3 M and [NaHCO3]T = 10-3 M c. Carbonate/Dissolution/Complexation (40 pts.) a. Sketch a logC-pH diagram for H2S, with [H2S]T = 10-5 M. b. At what pH will Zn

  11. Hydraulics, CIET 3132 Spring 1998, Bowen

    E-Print Network [OSTI]

    Bowen, James D.

    . Estimate the flow rate, using the Darcy equation, including local losses. Do only one iteration. Bernoulli Equation (20 points) Oil flows from a tank into the air, as shown below. What is the total head flows through a new 12-inch, cast-iron pipe at 3 ft/s. Using the Hazen-Williams equation, estimate

  12. Project X Energy Station Workshop Report. Report by the Organizers and Co-Conveners of the Project X Energy Station Workshop

    SciTech Connect (OSTI)

    Asner, David M.; Hurh, Patrick; Brady Raap, Michaele C.; Gohar, Yoursy; Peterson, Mary E.; Pithcer, Eric; Riemer, Bernie; Senor, David J.; Wootan, David W.

    2013-06-14T23:59:59.000Z

    Project X Energy Station Workshop Report Report by the Organizers and Co-Conveners of the Project X Energy Station Workshop

  13. Final environmental assessment for vegetation control at VHF stations, microwave stations, electrical substations, and pole yards

    SciTech Connect (OSTI)

    NONE

    1995-10-13T23:59:59.000Z

    Southwestern Power Adm. operates very high frequency (VHF) and microwave radio stations, electrical substations, and pole yards for electric power transmission throughout AR, MO, and OK. Vegetation growth at the stations must be suppressed for safety of operation and personnel. Southwestern has been using a combination of mechanical/manual and herbicide control for this purpose; Federally- mandated reductions in staff and budgetary resources require Southwestern to evaluate all potentially efficient methods for vegetation control. Three alternatives were examined: no action, mechanical/manual control, and (proposed) a combination of mechanical/manual and herbicide control. Environmental impacts on air and water quality, wetlands, wildlife, endangered species, archaeological and other resources, farmland, human health, transportation, etc. were evaluated.

  14. Ratio model serves suprathreshold color luminance discrimination

    E-Print Network [OSTI]

    Mullen, Kathy T.

    Ratio model serves suprathreshold color­ luminance discrimination Marcel J. Sankeralli and Kathy T quadrants of the red­ green/luminance and blue­yellow/luminance planes of cardinal color space. We showed model of suprathreshold color­luminance dis- crimination, in which discrimination depends on a ratio

  15. Field Stations Compliance CommitteesAdministrative Units Research Units

    E-Print Network [OSTI]

    Walker, Matthew P.

    ) Center for Integrative Planetary Science Center for Latin American Studies Center for Medicine Museums Blue Oak Ranch Reserve Donner Region-Field Research Stations -Chickering American River Reserve, Ecology and Reproduction Gump South Pacific Research Station Hans Jenny Pygmy Forest Reserve Hastings

  16. Achieving High Chilled Water Delta T Without Blending Station

    E-Print Network [OSTI]

    Wang, Z.; Wang, G.; Xu, K.; Yu, Y.; Liu, M.

    2007-01-01T23:59:59.000Z

    on the blending station performance. The results show that the blending station is not necessary in the building chilled water systems with 2-way modulation valves at end users. Actually the end user valve configuration and control mainly impacts building chilled...

  17. High Transformer ratios in collinear wakefield accelerators.

    SciTech Connect (OSTI)

    Power, J. G.; Conde, M.; Yusof, Z.; Gai, W.; Jing, C.; Kanreykin, A.; Schoessow, P.; High Energy Physics; Euclid Techlabs, LLC

    2008-01-01T23:59:59.000Z

    Based on our previous experiment that successfully demonstrated wakefield transformer ratio enhancement in a 13.625 GHz dielectric-loaded collinear wakefield accelerator using the ramped bunch train technique, we present here a redesigned experimental scheme for even higher enhancement of the efficiency of this accelerator. Design of a collinear wakefield device with a transformer ratio R2, is presented. Using a ramped bunch train (RBT) rather than a single drive bunch, the enhanced transformer ratio (ETR) technique is able to increase the transformer ratio R above the ordinary limit of 2. To match the wavelength of the fundamental mode of the wakefield with the bunch length (sigmaz=2 mm) of the new Argonne wakefield accelerator (AWA) drive gun (where the experiment will be performed), a 26.625 GHz dielectric based accelerating structure is required. This transformer ratio enhancement technique based on our dielectric-loaded waveguide design will result in a compact, high efficiency accelerating structures for future wakefield accelerators.

  18. Validation of an Integrated Hydrogen Energy Station

    SciTech Connect (OSTI)

    Edward C. Heydorn

    2012-10-26T23:59:59.000Z

    This report presents the results of a 10-year project conducted by Air Products and Chemicals, Inc. (Air Products) to determine the feasibility of coproducing hydrogen with electricity. The primary objective was to demonstrate the technical and economic viability of a hydrogen energy station using a high-temperature fuel cell designed to produce power and hydrogen. This four-phase project had intermediate go/no-go decisions and the following specific goals: �¢���¢ Complete a technical assessment and economic analysis of the use of high-temperature fuel cells, including solid oxide and molten carbonate, for the co-production of power and hydrogen (energy park concept). �¢���¢ Build on the experience gained at the Las Vegas H2 Energy Station and compare/contrast the two approaches for co-production. �¢���¢ Determine the applicability of co-production from a high-temperature fuel cell for the existing merchant hydrogen market and for the emerging hydrogen economy. �¢���¢ Demonstrate the concept on natural gas for six months at a suitable site with demand for both hydrogen and electricity. �¢���¢ Maintain safety as the top priority in the system design and operation. �¢���¢ Obtain adequate operational data to provide the basis for future commercial activities, including hydrogen fueling stations. Work began with the execution of the cooperative agreement with DOE on 30 September 2001. During Phase 1, Air Products identified high-temperature fuel cells as having the potential to meet the coproduction targets, and the molten carbonate fuel cell system from FuelCell Energy, Inc. (FuelCell Energy) was selected by Air Products and DOE following the feasibility assessment performed during Phase 2. Detailed design, construction and shop validation testing of a system to produce 250 kW of electricity and 100 kilograms per day of hydrogen, along with site selection to include a renewable feedstock for the fuel cell, were completed in Phase 3. The system also completed six months of demonstration operation at the wastewater treatment facility operated by Orange County Sanitation District (OCSD, Fountain Valley, CA). As part of achieving the objective of operating on a renewable feedstock, Air Products secured additional funding via an award from the California Air Resources Board. The South Coast Air Quality Management District also provided cost share which supported the objectives of this project. System operation at OCSD confirmed the results from shop validation testing performed during Phase 3. Hydrogen was produced at rates and purity that met the targets from the system design basis, and coproduction efficiency exceeded the 50% target set in conjunction with input from the DOE. Hydrogen production economics, updated from the Phase 2 analysis, showed pricing of $5 to $6 per kilogram of hydrogen using current gas purification systems. Hydrogen costs under $3 per kilogram are achievable if next-generation electrochemical separation technologies become available.

  19. A computer program for HVDC converter station RF noise calculations

    SciTech Connect (OSTI)

    Kasten, D.G.; Caldecott, R.; Sebo, S.A. (Ohio State Univ., Columbus, OH (United States). Dept. of Electrical Engineering); Liu, Y. (Virginia Polytechnic Inst. State Univ., Blacksburg, VA (United States). Bradley Dept. of Electrical Engineering)

    1994-04-01T23:59:59.000Z

    HVDC converter station operations generate radio frequency (RF) electromagnetic (EM) noise which could interfere with adjacent communication and computer equipment, and carrier system operations. A generic Radio Frequency Computer Analysis Program (RAFCAP) for calculating the EM noise generated by valve ignition of a converter station has been developed as part of a larger project. The program calculates RF voltages, currents, complex power, ground level electric field strength and magnetic flux density in and around an HVDC converter station. The program requires the converter station network to be represented by frequency dependent impedance functions. Comparisons of calculated and measured values are given for an actual HVDC station to illustrate the validity of the program. RAFCAP is designed to be used by engineers for the purpose of calculating the RF noise produced by the igniting of HVDC converter valves.

  20. Compression station key to Texas pipeline project

    SciTech Connect (OSTI)

    NONE

    1996-10-01T23:59:59.000Z

    This was probably the largest pipeline project in the US last year, and the largest in Texas in the last decade. The new compressor station is a key element in this project. TECO, its servicing dealer, and compression packager worked closely throughout the planning and installation stages of the project. To handle the amount of gas required, TECO selected the GEMINI F604-1 compressor, a four-throw, single-stage unit with a six-inch stroke manufactured by Weatherford Enterra Compression Co. (WECC) in Corpus Christi, TX. TECO also chose WECC to package the compressors. Responsibility for ongoing support of the units will be shared among TECO, the service dealer and the packager. TECO is sending people to be trained by WECC, and because the G3600 family of engines is still relatively new, both the Caterpillar dealer and WECC sent people for advanced training at Caterpillar facilities in Peoria, IL. As part of its service commitment to TECO, the servicing dealer drew up a detailed product support plan, encompassing these five concerns: Training, tooling; parts support; service support; and commissioning.

  1. Solar-Assisted Electric Vehicle Charging Station Interim Report

    SciTech Connect (OSTI)

    Lapsa, Melissa Voss [ORNL; Durfee, Norman [ORNL; Maxey, L Curt [ORNL; Overbey, Randall M [ORNL

    2011-09-01T23:59:59.000Z

    Oak Ridge National Laboratory (ORNL) has been awarded $6.8 million in the Department of Energy (DOE) American Recovery and Reinvestment Act (ARRA) funds as part of an overall $114.8 million ECOtality grant with matching funds from regional partners to install 125 solar-assisted Electric Vehicle (EV) charging stations across Knoxville, Nashville, Chattanooga, and Memphis. Significant progress has been made toward completing the scope with the installation of 25 solar-assisted charging stations at ORNL; six stations at Electric Power Research Institute (EPRI); and 27 stations at Nissan's Smyrna and Franklin sites, with three more stations under construction at Nissan's new lithium-ion battery plant. Additionally, the procurement process for contracting the installation of 34 stations at Knoxville, the University of Tennessee Knoxville (UTK), and Nashville sites is underway with completion of installation scheduled for early 2012. Progress is also being made on finalizing sites and beginning installations of 30 stations in Nashville, Chattanooga, and Memphis by EPRI and Tennessee Valley Authority (TVA). The solar-assisted EV charging station project has made great strides in fiscal year 2011. A total of 58 solar-assisted EV parking spaces have been commissioned in East and Middle Tennessee, and progress on installing the remaining 67 spaces is well underway. The contract for the 34 stations planned for Knoxville, UTK, and Nashville should be underway in October with completion scheduled for the end of March 2012; the remaining three Nissan stations are under construction and scheduled to be complete in November; and the EPRI/TVA stations for Chattanooga, Vanderbilt, and Memphis are underway and should be complete by the end of March 2012. As additional Nissan LEAFs are being delivered, usage of the charging stations has increased substantially. The project is on course to complete all 125 solar-assisted EV charging stations in time to collect meaningful data by the end of government fiscal year 2012. Lessons learned from the sites completed thus far are being incorporated and are proving to be invaluable in completion of the remaining sites.

  2. Design of high pressure metering and regulating stations

    SciTech Connect (OSTI)

    Rehler, D.A. [Oklahoma Natural Gas Co., Enid, OK (United States)

    1995-12-01T23:59:59.000Z

    Metering and regulating stations effectively serve as the cash registers of the natural gas industry. While the potential for lost revenue resulting from improper design is a serious consideration, it is not the only one. The potential exists for problems such as excessive noise levels, inaccurate reflection of lost and unaccounted-for gas, and numerous potentially hazardous situations. The best time to limit the potential for problems is during the design process. This, together with the critical nature of these stations, dictates that proper design is imperative. Proper design of metering and regulating stations is a constantly changing and extremely complicated subject. There are virtually an infinite number of situations that the designer can encounter in evaluating his design. In view of this, it is impossible to develop a cookbook method of designing these stations that covers all possible situations. The emphasis of this paper is to briefly touch on the major aspects of metering and regulating station design. Steps involved in station design are: 1. Collection of data on the proposed station. 2. Determination of piping configuration. 3. Selection of measurement equipment. 4. Selection of pressure regulating and overpressure protection equipment. 5. Communication of the final design to field personnel.

  3. OPTIMIZING PERFORMANCE OF THE HESKETT STATION

    SciTech Connect (OSTI)

    Michael D. Mann; Ann K. Henderson

    1999-03-01T23:59:59.000Z

    The overall conclusion from this work is that a switch from river sand bed material to limestone at the R.M. Heskett Station would provide substantial benefits to MDU. A switch to limestone would increase the fuel flexibility of the unit, allowing fuels higher in both sodium and sulfur to be burned. The limestone bed can tolerate a much higher buildup of sodium in the bed without agglomeration, allowing either the bed turnover rate to be reduced to half the current sand feed rate for a fuel with equivalent sodium or allow a higher sodium fuel to be burned with limestone feed rates equivalent to the current sand feed rate. Both stack and ambient SO{sub 2} emissions can be controlled. A small improvement in boiler efficiency should be achievable by operating at lower excess oxygen levels at low load. This reduction in oxygen will also lower NO{sub x} emissions, providing a margin of safety for meeting emission standards. No detrimental effects of using limestone at the Heskett Station were uncovered as a result of the test burn. Some specific conclusions from this work include the following: The bed material feed rate can be reduced from the current rate of 5.4% of the coal feed rate (57.4 tons of sand/day) to 2.5% of the coal feed rate (27 tons of limestone/day). This will result in an annual savings of approximately $200,000. (1) SO{sub 2} emissions at the recommended feed rate would be approximately 250 ppm (0.82 lb/MMBtu) using a similar lignite. Based on the cost of the limestones, SO{sub 2} allowances could be generated at a cost of $60/ton SO{sub 2} , leaving a large profit margin for the sale of allowances. The addition of limestone at the same rate currently used for sand feed could generate $455,000 net income if allowances are sold at $200/ton SO2 . (2) At full-load operation, unburned carbon losses increase significantly at excess oxygen levels below 2.8%. No efficiency gains are expected at high-load operation by switching from sand to limestone. By reducing the oxygen level at low load to 8.5%, an efficiency gain of approximately 1.2% could be realized, equating to $25,000 to $30,000 in annual savings. (3) A reduction of 25 tons/day total ash (bed material plus fly ash) will be realized by using limestone at the recommended feed rate compared to the current sand feed rate. No measurable change in volume would be realized because of the lower bulk density of the limestone-derived material.

  4. Bridging the Gap Between Transportation and Stationary Power: Hydrogen Energy Stations and their Implications for the Transportation Sector

    E-Print Network [OSTI]

    Weinert, Jonathan X.; Lipman, Timothy; Unnasch, Stephen

    2005-01-01T23:59:59.000Z

    Economic Analysis of Hydrogen Energy Station Concepts,E 2 Four Potential Types of Hydrogen Energy Stations VehicleOperational Toronto Hydrogen Energy Station Stationary PEMFC

  5. Buried waste integrated demonstration human engineered control station. Final report

    SciTech Connect (OSTI)

    Not Available

    1994-09-01T23:59:59.000Z

    This document describes the Human Engineered Control Station (HECS) project activities including the conceptual designs. The purpose of the HECS is to enhance the effectiveness and efficiency of remote retrieval by providing an integrated remote control station. The HECS integrates human capabilities, limitations, and expectations into the design to reduce the potential for human error, provides an easy system to learn and operate, provides an increased productivity, and reduces the ultimate investment in training. The overall HECS consists of the technology interface stations, supporting engineering aids, platform (trailer), communications network (broadband system), and collision avoidance system.

  6. SOARCA Peach Bottom Atomic Power Station Long-Term Station Blackout Uncertainty Analysis: Knowledge Advancement.

    SciTech Connect (OSTI)

    Gauntt, Randall O.; Mattie, Patrick D.; Bixler, Nathan E.; Ross, Kyle; Cardoni, Jeffrey N; Kalinich, Donald A.; Osborn, Douglas M.; Sallaberry, Cedric Jean-Marie; Ghosh, S. Tina

    2014-02-01T23:59:59.000Z

    This paper describes the knowledge advancements from the uncertainty analysis for the State-of- the-Art Reactor Consequence Analyses (SOARCA) unmitigated long-term station blackout accident scenario at the Peach Bottom Atomic Power Station. This work assessed key MELCOR and MELCOR Accident Consequence Code System, Version 2 (MACCS2) modeling uncertainties in an integrated fashion to quantify the relative importance of each uncertain input on potential accident progression, radiological releases, and off-site consequences. This quantitative uncertainty analysis provides measures of the effects on consequences, of each of the selected uncertain parameters both individually and in interaction with other parameters. The results measure the model response (e.g., variance in the output) to uncertainty in the selected input. Investigation into the important uncertain parameters in turn yields insights into important phenomena for accident progression and off-site consequences. This uncertainty analysis confirmed the known importance of some parameters, such as failure rate of the Safety Relief Valve in accident progression modeling and the dry deposition velocity in off-site consequence modeling. The analysis also revealed some new insights, such as dependent effect of cesium chemical form for different accident progressions. (auth)

  7. Tri-Generation Success Story: World's First Tri-Gen EnergyStation...

    Energy Savers [EERE]

    Energy Department, the Fountain Valley energy station is the world's first tri-generation hydrogen energy and electrical power station to provide transportation fuel to the public...

  8. Survey Results and Analysis of the Cost and Efficiency of Various Operating Hydrogen Fueling Stations

    SciTech Connect (OSTI)

    Cornish, John

    2011-03-05T23:59:59.000Z

    Existing Hydrogen Fueling Stations were surveyed to determine capital and operational costs. Recommendations for cost reduction in future stations and for research were developed.

  9. Fact #874: May 25, 2015 Number of Electric Stations and Electric...

    Energy Savers [EERE]

    74: May 25, 2015 Number of Electric Stations and Electric Charging Units Increasing - Dataset Fact 874: May 25, 2015 Number of Electric Stations and Electric Charging Units...

  10. Strategy for international cooperation in planning the Chinese Space Station

    E-Print Network [OSTI]

    Foley, Jordan J. (Jordan James)

    2014-01-01T23:59:59.000Z

    After ten years of planning and pre-development, the Chinese government approved the space station project on September 25, 2010. In October 2010, the People's Republic of China (PRC) officially announced its independent ...

  11. College Station Utilities- Residential Energy Back II Rebate Program

    Broader source: Energy.gov [DOE]

    College Station Utilities offers an incentive for residential customers to install energy efficient HVAC equipment through the Energy Back II Program. To qualify for the rebate, the A/C system...

  12. Niwot Ridge CRN Station Up & On-Line.

    E-Print Network [OSTI]

    Niwot Ridge CRN Station Up & On-Line. I made a decision after the Science Panel Review to put tree removal Wind Speed 3, terrain elevation change Solar Radiation 3, solar shading to west #12;

  13. Development of a Turnkey Hydrogen Fueling Station Final Report

    SciTech Connect (OSTI)

    David E. Guro; Edward Kiczek; Kendral Gill; Othniel Brown

    2010-07-29T23:59:59.000Z

    The transition to hydrogen as a fuel source presents several challenges. One of the major hurdles is the cost-effective production of hydrogen in small quantities (less than 1MMscf/month). In the early demonstration phase, hydrogen can be provided by bulk distribution of liquid or compressed gas from central production plants; however, the next phase to fostering the hydrogen economy will likely include onsite generation and extensive pipeline networks to help effect a pervasive infrastructure. Providing inexpensive hydrogen at a fleet operator’s garage or local fueling station is a key enabling technology for direct hydrogen Fuel Cell Vehicles (FCVs). The objective of this project was to develop a comprehensive, turnkey, stand-alone, commercial hydrogen fueling station for FCVs with state-of-the-art technology that is cost-competitive with current hydrocarbon fuels. Such a station would promote the advent of the hydrogen fuel economy for buses, fleet vehicles, and ultimately personal vehicles. Air Products, partnering with the U.S. Department of Energy (DOE), The Pennsylvania State University, Harvest Energy Technology, and QuestAir, developed a turnkey hydrogen fueling station on the Penn State campus. Air Products aimed at designing a station that would have 65% overall station efficiency, 82% PSA (pressure swing adsorption) efficiency, and the capability of producing hydrogen at $3.00/kg (gge) H2 at mass production rates. Air Products designed a fueling station at Penn State from the ground up. This project was implemented in three phases. The first phase evaluated the various technologies available in hydrogen generation, compression, storage, and gas dispensing. In the second phase, Air Products designed the components chosen from the technologies examined. Finally, phase three entailed a several-month period of data collection, full-scale operation, maintenance of the station, and optimization of system reliability and performance. Based on field data analysis, it was determined by a proprietary hydrogen-analysis model that hydrogen produced from the station at a rate of 1500 kg/day and when produced at 1000 stations per year would be able to deliver hydrogen at a price of $3.03/kg (gge) H2. The station’s efficiency was measured to be 65.1%, and the PSA was tested and ran at an efficiency of 82.1%, thus meeting the project targets. From the study, it was determined that more research was needed in the area of hydrogen fueling. The overall cost of the hydrogen energy station, when combined with the required plot size for scaled-up hydrogen demands, demonstrated that a station using steam methane reforming technology as a means to produce on–site hydrogen would have limited utility in the marketplace. Alternative hydrogen supplies, such as liquid or pipeline delivery to a refueling station, need to be included in the exploration of alternative energy site layouts. These avenues need to be explored before a definitive refueling station configuration and commercialization pathway can be determined.

  14. Where the Rubber Meets the Road -- the Alternative Fuel Station...

    Broader source: Energy.gov (indexed) [DOE]

    Road -- the Alternative Fuel Station Locator August 10, 2010 - 2:32pm Addthis Dennis A. Smith Director, National Clean Cities Last week, this blog highlighted the highly efficient...

  15. Optimal command generation for maneuvering the space station

    E-Print Network [OSTI]

    Bryson, Amy Louise

    2001-01-01T23:59:59.000Z

    The objective of this research is to obtain near minimum-fuel and minimum-time maneuver commands for large-angle maneuvers for the international space station. Attitude and angular velocity waypoints are generated using the method of differential...

  16. Enhancing the energy efficiency of radio base stations 

    E-Print Network [OSTI]

    Holtkamp, Hauke Andreas

    2014-06-30T23:59:59.000Z

    This thesis is concerned with the energy efficiency of cellular networks. It studies the dominant power consumer in future cellular networks, the Long Term Evolution (LTE) radio Base Station (BS), and proposes mechanisms ...

  17. New tool predicts economic impacts of natural gas stations |...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    announced a new tool today for analyzing the economic impacts of building new compressed natural gas fueling stations. Called JOBS NG, the tool is freely available to the public....

  18. The CNGS Target Station Presented by L.Bruno

    E-Print Network [OSTI]

    McDonald, Kirk

    sealed system filled with 0.5 bar of He. The tube has annular fins to enhance convective heat transfer enclosure Inlet target Inlet fixed shielding Outlet Beam #12;The target Assembly The CNGS Target Station as

  19. Effective Load Management for the City of College Station

    E-Print Network [OSTI]

    Hecox, O. D.; Bauer, V.

    1985-01-01T23:59:59.000Z

    A successful electrical demand management program for the City of College Station in 1984 employed techniques proven in the industrial and commercial sectors that have seldom been used at the community level. The program, with technical assistance...

  20. air station whidbey: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    on Soil Organic Matter and Nutrient Levels Clain Jones, Perry Lawrence, Rick L. 47 OF CAR SHARING STATIONS CiteSeer Summary: Approximately half of the worlds population is...

  1. automatic interplanetary station: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    A; Pantellini, F; Meyer-Vernet, N; Belheouane, S; Maksimovic, M 2015-01-01 135 OF CAR SHARING STATIONS CiteSeer Summary: Approximately half of the worlds population is...

  2. air station lemoore: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    on Soil Organic Matter and Nutrient Levels Clain Jones, Perry Lawrence, Rick L. 47 OF CAR SHARING STATIONS CiteSeer Summary: Approximately half of the worlds population is...

  3. arctowski station king: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    using Ranked statistical inference about P(Yusing simple random Omar, Mohammad H. 139 OF CAR SHARING STATIONS CiteSeer Summary: Approximately half of the worlds population is...

  4. australian antarctic station: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    arise from splittings of the natural short exact sequences Ross Street 2004-01-01 219 OF CAR SHARING STATIONS CiteSeer Summary: Approximately half of the worlds population is...

  5. antarctic station casey: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    SOAP for setting up the tetheredsonde All of the Costa Rica REU groups for data 148 OF CAR SHARING STATIONS CiteSeer Summary: Approximately half of the worlds population is...

  6. air force station: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of intensity and the lifespan of certain isotopes. A Siemens Simatic FM-352-5 module controls the Tape Station in a PLC system then a DSC controls the PLC, which will be...

  7. Transfer stations and long-haul transport systems

    SciTech Connect (OSTI)

    Walsh, P.; Pferdehirt, W.; O'Leary, P. (Univ. of Wisconsin, Madison, WI (United States). Solid and Hazardous Waste Education Center)

    1993-12-01T23:59:59.000Z

    Transfer stations can be an important link between pickup at the curb and ultimate disposal, often allowing significant savings in the total costs to move wastes from the generator to the disposal site. A transfer station is simply a facility where collection trucks bring collected materials for loading into larger vehicles and subsequent shipment, usually to a landfill, waste-to-energy plant, or composting facility. Transferred wastes are typically shipped out in large trailers, but barges and railroad cars are also transport options. Although modern transfer stations usually include some provisions for handling recyclables, solid waste transfer dominates the operation of most facilities. Some communities have begun experimenting with transferring commingled, source-separated recyclables to regional processing centers. Transfer facilities can be as simple as a pavement slab and a front-end loader. Alternatively, transfer stations can cost millions of dollars and move thousands of tons of waste each day.

  8. Southwest Region Experiment Station - Final Technical Report

    SciTech Connect (OSTI)

    Rosenthal, A

    2011-08-19T23:59:59.000Z

    Southwest Technology Development Institute (SWTDI), an independent, university-based research institute, has been the operator of the Southwest Region Photovoltaic Experiment Station (SWRES) for almost 30 years. The overarching mission of SWTDI is to position PV systems and solar technologies to become cost-effective, major sources of energy for the United States. Embedded in SWTDI's general mission has been the more-focused mission of the SWRES: to provide value added technical support to the DOE Solar Energy Technologies Program (SETP) to effectively and efficiently meet the R&D needs and targets specified in the SETP Multi-Year Technical Plan. : The DOE/SETP goals of growing U.S. PV manufacturing into giga-watt capacities and seeing tera-watt-hours of solar energy production in the U.S. require an infrastructure that is under development. The staff of the SWRES has supported DOE/SETP through a coherent, integrated program to address infrastructural needs inhibiting wide-scale PV deployment in three major technical categories: specialized engineering services, workforce development, and deployment facilitation. The SWRES contract underwent three major revisions during its five year period-of- performance, but all tasks and deliverables fell within the following task areas: Task 1: PV Systems Assistance Center 1. Develop a Comprehensive multi-year plan 2. Provide technical workforce development materials and workshops for PV stakeholder groups including university, professional installers, inspectors, state energy offices, Federal agencies 3. Serve on the NABCEP exam committee 4. Provide on-demand technical PV system design reviews for U.S. PV stakeholders 5. Provide PV system field testing and instrumentation, technical outreach (including extensive support for the DOE Market Transformation program) Task 2: Design-for-Manufacture PV Systems 1. Develop and install 18 kW parking carport (cost share) and PV-thermal carport (Albuquerque) deriving and publishing lessons learned Task 3: PV Codes and Standards 1. Serve as the national lead for development and preparation of all proposals (related to PV) to the National Electrical Code 2. Participate in the Standards Technical Panels for modules (UL1703) and inverters (UL1741) Task 4: Assess Inverter Long Term Reliability 1. Install and monitor identical inverters at SWRES and SERES 2. Operate and monitor all inverters for 5 years, characterizing all failures and performance trends Task 5: Test and Evaluation Support for Solar America Initiative 1. Provide test and evaluation services to the National Laboratories for stage gate and progress measurements of SAI TPP winners

  9. Large Optic Drying Station: Summary of Dryer Certification Tests

    SciTech Connect (OSTI)

    Barbee, T W; Ayers, S L; Ayers, M J

    2009-08-28T23:59:59.000Z

    The purpose of this document is to outline the methodology used to baseline and maintain the cleanliness status of the newly built and installed Large Optic Cleaning Station (LOCS). The station has currently been in use for eleven months; and after many cleaning studies and implementation of resulting improvements appears to be cleaning optics to a level that is acceptable for the fabrication of Nano-Laminates.

  10. Radioactive anomaly discrimination from spectral ratios

    DOE Patents [OSTI]

    Maniscalco, James; Sjoden, Glenn; Chapman, Mac Clements

    2013-08-20T23:59:59.000Z

    A method for discriminating a radioactive anomaly from naturally occurring radioactive materials includes detecting a first number of gamma photons having energies in a first range of energy values within a predetermined period of time and detecting a second number of gamma photons having energies in a second range of energy values within the predetermined period of time. The method further includes determining, in a controller, a ratio of the first number of gamma photons having energies in the first range and the second number of gamma photons having energies in the second range, and determining that a radioactive anomaly is present when the ratio exceeds a threshold value.

  11. AEC Lowman Station - coal switching and magnesium-enhanced lime scrubbing to lower operating costs

    SciTech Connect (OSTI)

    Inkenhaus, W.; Babu, M.; Smith, K. [Dravo Lime Co., Pittsburgh, PA (United States); Loper, L. [Alabama Electric Coopreative, Leroy, AL (United States)

    1997-12-31T23:59:59.000Z

    AEC`s Lowman Station is located in Leroy, Alabama. There are three coal-fired boilers at this station. Unit 1 is capable of generating 85 MW without a flue gas desulfurization, FGD, system. Units 2 and 3, with a total of 516 MW output capacity, are equipped with FGD systems. The FGD plant was designed for wet limestone FGD with natural oxidation. Lowman Station burned low sulfur, 1.3 to 1.8% sulfur, coal. In January of 1996 AEC switched Units 2 and 3 from limestone to magnesium-enhanced lime FGD operation. It was determined that the plant could take advantage of the higher SO{sub 2} removal efficiency of the magnesium-enhanced lime system. Major benefits resulting from this conversion were AEC`s ability to switch to a lower cost high sulfur coal while meeting the stringent SO{sub 2} emission requirements. Power cost savings resulted from the lower liquid to gas ratio required by the magnesium-enhanced lime process. Three recirculation pumps per module were reduced to a single operating pump per module, lowering the scrubber pressure drop. Significant cost reduction in the operating costs of the ball mill was realized due to modifications made to slake lime instead of grinding limestone. Prior to switching, personnel from AEC and Dravo Lime Company ran a four week test on magnesium-enhanced lime to obtain scrubber performance data including SO{sub 2} removal efficiencies on the modules while burning a 1.8% sulfur coal. This paper discusses the plant modifications that were needed to make the switch, cost justifications due to coal switching, and AEC`s operating experiences to date. AEC and Dravo Lime Company working together as a team conducted detailed cost studies, followed by extensive field tests and implemented the plant modifications. This plant continues to operate burning higher sulfur coal with the magnesium-enhanced lime FGD system.

  12. Viscosity to entropy ratio at extremality

    E-Print Network [OSTI]

    Sayan K. Chakrabarti; Sachin Jain; Sudipta Mukherji

    2010-01-19T23:59:59.000Z

    Assuming gauge theory realization at the boundary, we show that the viscosity to entropy ratio is 1/(4 pi) where the bulk is represented by a large class of extremal black holes in anti-de Sitter space. In particular, this class includes multiple R-charged black holes in various dimensions.

  13. Ratio method of measuring $w$ boson mass

    SciTech Connect (OSTI)

    Guo, Feng; /SUNY, Stony Brook

    2010-08-01T23:59:59.000Z

    This dissertation describes an alternative method of measuring the W boson mass in D0 experiment. Instead of extracting M{sub W} from the fitting of W {yields} e{nu} fast Monte Carlo simulations to W {yields} e{nu} data as in the standard method, we make the direct fit of transverse mass between W {yields} e{nu} data and Z {yields} ee data. One of the two electrons from Z boson is treated as a neutrino in the calculation of transverse mass. In ratio method, the best fitted scale factor corresponds to the ratio of W and Z boson mass (M{sub W}/M{sub Z}). Given the precisely measured Z boson mass, W mass is directly fitted from W {yields} e{nu} and Z {yields} ee data. This dissertation demonstrates that ratio method is a plausible method of measuring the W boson mass. With the 1 fb{sup -1} D0 Run IIa dataset, ratio method gives M{sub W} = 80435 {+-} 43(stat) {+-} 26(sys) MeV.

  14. ARM: Broadband Radiometer Station (BRS) broadband shortwave and longwave 1-min radiation data with Dutton correction

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Stoffel, Tom; Kay, Bev; Habte, Aron; Anderberg, Mary; Kutchenreiter, Mark

    Broadband Radiometer Station (BRS) broadband shortwave and longwave 1-min radiation data with Dutton correction

  15. The correlation of carbohydrate/nitrogen ratios and rooting ability of Rosa multiflora stem cuttings 

    E-Print Network [OSTI]

    Hambrick, Carroll Edward

    1985-01-01T23:59:59.000Z

    ION ~KmU MEDICINE SOW FORMATION ~KIT LEWIS SHALE 8 IMT MESA VERDE GROUP FAULT ~--M. . . . . (DA5HEO WHERE APPROKIMATE, DOTTED WHERE CDNCEALEDI BASIN AXIS (APFROXIMATE) W Y 0 MING I I j-43 HANNA 845(N O &42 I I I 0 108 105 Figure l... the Medicine Bow Formation. It consists of 2000 m of 1 ate Cretaceous to Paleocene cong lomeratic sandstone, sandstone, shale, and coal (Bowen, 1918). Ryan (1977) suggested that the Ferris sediments were deposited by a fluv iatile system originating...

  16. The correlation of carbohydrate/nitrogen ratios and rooting ability of Rosa multiflora stem cuttings

    E-Print Network [OSTI]

    Hambrick, Carroll Edward

    1985-01-01T23:59:59.000Z

    ION ~KmU MEDICINE SOW FORMATION ~KIT LEWIS SHALE 8 IMT MESA VERDE GROUP FAULT ~--M. . . . . (DA5HEO WHERE APPROKIMATE, DOTTED WHERE CDNCEALEDI BASIN AXIS (APFROXIMATE) W Y 0 MING I I j-43 HANNA 845(N O &42 I I I 0 108 105 Figure l... the Medicine Bow Formation. It consists of 2000 m of 1 ate Cretaceous to Paleocene cong lomeratic sandstone, sandstone, shale, and coal (Bowen, 1918). Ryan (1977) suggested that the Ferris sediments were deposited by a fluv iatile system originating...

  17. PV powering a weather station for severe weather

    SciTech Connect (OSTI)

    Young, W. Jr. [Florida Solar Energy Center, Cocoa, FL (United States); Schmidt, J. [Joe Schmidt, Inc., Miami, FL (United States)

    1997-12-31T23:59:59.000Z

    A natural disaster, such as Hurricane Andrew, destroys thousands of homes and businesses. The destruction from this storm left thousands of people without communications, potable water, and electrical power. This prompted the Florida Solar Energy Center to study the application of solar electric power for use in disasters. During this same period, volunteers at the Tropical Prediction Center at the National Hurricane Center (NHC), Miami, Florida and the Miami Office of the National Weather Service (NWS) were working to increase the quantity and quality of observations received from home weather stations. Forecasters at NHC have found surface reports from home weather stations a valuable tool in determining the size, strength and course of hurricanes. Home weather stations appear able to record the required information with an adequate level of accuracy. Amateur radio, utilizing the Automatic Packet Report System, (APRS) can be used to transmit this data to weather service offices in virtually real time. Many weather data collecting stations are at remote sites which are not readily serviced by dependable commercial power. Photovoltaic (solar electric) modules generate electricity and when connected to a battery can operate as a stand alone power system. The integration of these components provides an inexpensive standalone system. The system is easy to install, operates automatically and has good communication capabilities. This paper discusses the design criteria, operation, construction and deployment of a prototype solar powered weather station.

  18. INVESTIGATION OF HYDRAULIC PROBLEMS IN PUMPING STATION; CASE STUDY

    E-Print Network [OSTI]

    M. A. Younes

    Pumping stations play an important role in agriculture development projects. Performance of the pumping stations should satisfy water requirements, and management. There are many problems face these pumping stations affecting their reliability and stability. Hydraulic problems are the most important item in the field of pumping station operation and design. Motivation of this research was presence of wear and pitting impellers and casing of double suction volute casing centrifugal pumps for Ahmed Orabee Pumping Station. Vibration level, hydraulic performance test and visual inspection of impeller wear and pitting show that cavitation problem is the cause of damage. Cavitation normally occurs when liquid at a constant temperature is subjected to vapor pressure either by static or dynamic means. If the local pressure somewhere in the fluid drops to or below vapor pressure and nuclei are present, vapor cavities can be formed. As long as the local pressure stays at vapor pressure and cavity has reached a critical diameter, it will continue to grow rapidly. If the surrounding pressure is above vapor pressure, the bubbles become unstable and collapse. The

  19. Blowing Ratio Effects on Film Cooling Effectiveness

    E-Print Network [OSTI]

    Liu, Kuo-Chun

    2010-01-14T23:59:59.000Z

    cooling Rib turbulators Shaped internal cooling passage Trailing edge ejection Cooling air 3 Among the variety of film cooling hole designs, compound angle and shaped holes are generally considered in modern high pressure and high temperature gas turbine... ratio of 1.85. As compared to cylindrical hole, both shaped holes showed significant improved thermal protection of the surface downstream of the ejection location. Yu et al. [7] studied film cooling effectiveness and heat transfer distributions on a...

  20. Locating PHEV Exchange Stations in V2G

    E-Print Network [OSTI]

    Pan, Feng; Berscheid, Alan; Izraelevitz, David

    2010-01-01T23:59:59.000Z

    Plug-in hybrid electric vehicles (PHEVs) are an environmentally friendly technology that is expected to rapidly penetrate the transportation system. Renewable energy sources such as wind and solar have received considerable attention as clean power options for future generation expansion. However, these sources are intermittent and increase the uncertainty in the ability to generate power. The deployment of PHEVs in a vehicle-to-grid (V2G) system provide a potential mechanism for reducing the variability of renewable energy sources. For example, PHEV supporting infrastructures like battery exchange stations that provide battery service to PHEV customers could be used as storage devices to stabilize the grid when renewable energy production is fluctuating. In this paper, we study how to best site these stations in terms of how they can support both the transportation system and the power grid. To model this problem we develop a two-stage stochastic program to optimally locate the stations prior to the realizat...

  1. aspect ratio wings: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  2. aspect ratios numerical: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  3. aspect ratio microstructuring: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  4. aspect ratio: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  5. average aspect ratios: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  6. aspect ratio tori: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  7. aspect ratio ion: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  8. aspect ratio su-8: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  9. aspect ratio micro: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  10. aspect ratio domains: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  11. aspect ratio electrodes: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  12. aspect ratio plasmas: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiency versus a function of mobility ratio and aspect ratio for staggered line-drive waterflood pattern Texas A&M University - TxSpace Summary: ratios on five-spot and...

  13. EIS-0210: Tampa Electric Company-Polk Power Station (Adopted)

    Broader source: Energy.gov [DOE]

    The U.S. Environmental Protection Agency prepared this statement to fulfill its National Environmental Policy Act requirements with respect to the potential issuance of a permit to the Tampa Electric Company under the National Pollutant Discharge Elimination System for the 1,150-MW Polk Power Station, a new pollutant source. The U.S. Department of Energy served as a cooperating agency in the development of this document due to its potential role to provide cost-shared financial assistance for a 260-MW Integrated Gasification Combined Cycle unit at the Power Station under its Clean Coal Technology Demonstration Project, and adopted the document by August 1994.

  14. Design of photovoltaic central power station concentrator array

    SciTech Connect (OSTI)

    Not Available

    1984-02-01T23:59:59.000Z

    A design for a photovoltaic central power station using tracking concentrators has been developed. The 100 MW plant is assumed to be located adjacent to the Saguaro Power Station of Arizona Public Service. The design assumes an advanced Martin Marietta two-axis tracking fresnel lens concentrator. The concentrators are arrayed in 5 MW subfields, each with its own power conditioning unit. The photovoltaic plant output is connected to the existing 115 kV switchyard. The site specific design allows detailed cost estimates for engineering, site preparation, and installation. Collector and power conditioning costs have been treated parametrically.

  15. Intra- and inter-unit variation in fly ash petrography: Examples from a western Kentucky power station

    SciTech Connect (OSTI)

    Hower, J.C.; Rathbone, R.F. [Univ. of Kentucky, Lexington, KY (United States). Center for Applied Energy Research; Goodman, J. [Prestonburg High School, KY (United States)

    1998-12-31T23:59:59.000Z

    Fly ash was collected from eight mechanical and ten baghouse hoppers at each of twin 150-MW wall-fired units in a western Kentucky power station. The fuel burned at that time was a blend of low-sulfur, high volatile bituminous Central Appalachian coals. The baghouse ash showed less variation between units than the mechanical units. The coarser mechanical fly ash showed significant differences in the amount of total carbon and in the ratio of isotropic coke to both total carbons and total coke; the latter excluding inertinite and other unburned, uncoked coal. There was no significant variation in ratios of inorganic fly ash constituents. The inter-unit differences in the amount and forms of mechanical fly ash carbon appear to be related to differences in pulverizer efficiency, leading to greater amounts of coarse coal, therefore unburned carbon, in one of the units.

  16. air-fuel ratio: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    was performed to investigate the effects of air-fuel ratio, inlet boost pressure, hydrogen rich fuel reformate, and compression ratio on engine knock behavior. For each...

  17. Implications of Fast Reactor Transuranic Conversion Ratio

    SciTech Connect (OSTI)

    Steven J. Piet; Edward A. Hoffman; Samuel E. Bays

    2010-11-01T23:59:59.000Z

    Theoretically, the transuranic conversion ratio (CR), i.e. the transuranic production divided by transuranic destruction, in a fast reactor can range from near zero to about 1.9, which is the average neutron yield from Pu239 minus 1. In practice, the possible range will be somewhat less. We have studied the implications of transuranic conversion ratio of 0.0 to 1.7 using the fresh and discharge fuel compositions calculated elsewhere. The corresponding fissile breeding ratio ranges from 0.2 to 1.6. The cases below CR=1 (“burners”) do not have blankets; the cases above CR=1 (“breeders”) have breeding blankets. The burnup was allowed to float while holding the maximum fluence to the cladding constant. We graph the fuel burnup and composition change. As a function of transuranic conversion ratio, we calculate and graph the heat, gamma, and neutron emission of fresh fuel; whether the material is “attractive” for direct weapon use using published criteria; the uranium utilization and rate of consumption of natural uranium; and the long-term radiotoxicity after fuel discharge. For context, other cases and analyses are included, primarily once-through light water reactor (LWR) uranium oxide fuel at 51 MWth-day/kg-iHM burnup (UOX-51). For CR<1, the heat, gamma, and neutron emission increase as material is recycled. The uranium utilization is at or below 1%, just as it is in thermal reactors as both types of reactors require continuing fissile support. For CR>1, heat, gamma, and neutron emission decrease with recycling. The uranium utilization exceeds 1%, especially as all the transuranic elements are recycled. exceeds 1%, especially as all the transuranic elements are recycled. At the system equilibrium, heat and gamma vary by somewhat over an order of magnitude as a function of CR. Isotopes that dominate heat and gamma emission are scattered throughout the actinide chain, so the modest impact of CR is unsurprising. Neutron emitters are preferentially found among the higher actinides, so the neutron emission varies much stronger with CR, about three orders of magnitude.

  18. High aspect ratio, remote controlled pumping assembly

    DOE Patents [OSTI]

    Brown, Steve B. (Livermore, CA); Milanovich, Fred P. (Lafayette, CA)

    1995-01-01T23:59:59.000Z

    A miniature dual syringe-type pump assembly which has a high aspect ratio and which is remotely controlled, for use such as in a small diameter penetrometer cone or well packer used in water contamination applications. The pump assembly may be used to supply and remove a reagent to a water contamination sensor, for example, and includes a motor, gearhead and motor encoder assembly for turning a drive screw for an actuator which provides pushing on one syringe and pulling on the other syringe for injecting new reagent and withdrawing used reagent from an associated sensor.

  19. Meteorological Effects on Air/Fuel Ratio

    E-Print Network [OSTI]

    Ferri, J. L.

    1984-01-01T23:59:59.000Z

    ) where subscript 1 indicates at condition 1 and subsc 1pt 2 Indicates at condition 2. Solving for E gives 2 100. (E . 13) Example 1 A furnace with a pressure type ratio control sys~em is calibrated at 10% excess air with 30 of air. If the air... of ... 30 of ... 460? 590 oR Substituting in Equation 13 and solving for E gives 2 E = (100 ... 10) (:;~)II, - 100 = 3.3% excess ir. 2 If the furnace had been calibrated to 10% excess air with iOO of air, the % excess air with 30 of air would bJI 590 II...

  20. High aspect ratio, remote controlled pumping assembly

    DOE Patents [OSTI]

    Brown, S.B.; Milanovich, F.P.

    1995-11-14T23:59:59.000Z

    A miniature dual syringe-type pump assembly is described which has a high aspect ratio and which is remotely controlled, for use such as in a small diameter penetrometer cone or well packer used in water contamination applications. The pump assembly may be used to supply and remove a reagent to a water contamination sensor, for example, and includes a motor, gearhead and motor encoder assembly for turning a drive screw for an actuator which provides pushing on one syringe and pulling on the other syringe for injecting new reagent and withdrawing used reagent from an associated sensor. 4 figs.

  1. VISITOR PARKING Pay station parking meters are available around

    E-Print Network [OSTI]

    temporary parking needs. Daily scratch-off permits are available in advance from Parking Services. LOT METER PAY STATION RATES (SUMMER RATES MAY BE DISCOUNTED) HOW DO I GET A PERMIT? When parking on campus, a CSM parking permit is required Monday through Friday, from 7AM until 5 PM. Permits authorize parking

  2. Leica EG1160 Compact, programmable tissue embedding station

    E-Print Network [OSTI]

    Adams, Mark

    and exemplary comfort and safety standards characterize this tissue embed- ding station as much of the Leica CLS series, with especially intense illumination and focusing fiber-optic light guide, to a vacuum / 60 Hz 230 V / 50 Hz Operating temperature range: 18 °C ­ 40 °C Dimensions (W x H x D): 910 x 320 x

  3. Field Stations Compliance CommitteesAdministrative Units Research Units

    E-Print Network [OSTI]

    Doudna, Jennifer A.

    for Integrative Planetary Science Center for Latin American Studies Center for Medicine, the Humanities & Law History Museums Blue Oak Ranch Reserve Donner Region-Field Research Stations -Chickering American River Reserve -Sagehen Creek -Central Sierra Snow Laboratory Essig Museum of Entomology Gump South Pacific

  4. Mississippi Agricultural and Forestry Experiment Station Vehicle Rental Request Form

    E-Print Network [OSTI]

    Ray, David

    Mississippi Agricultural and Forestry Experiment Station Vehicle Rental Request Form Driver Name Date: Travel Destination: Account #: Vehicle Information 1995 Crown Victoria 1995 Crown Victoria 1995 with the MSU Authorized Vehicle Use Policy. You further acknowledge that you have executed the Mississippi

  5. EIS-0415: Deer Creek Station Energy Facility Project, South Dakota

    Broader source: Energy.gov [DOE]

    This EIS analyzes WAPA's decision to approve the interconnection request made by Basin Electric Power Cooperative (Basin Electric) with the USDA Rural Utilities Service (RUS) proposing to provide financial assistance, for the Deer Creek Station Project, a proposed 300-megawatt (MW) natural gas-fired generation facility.

  6. DEVELOPMENT OF A TURNKEY COMMERCIAL HYDROGEN FUELING STATION

    E-Print Network [OSTI]

    from central production plants; however, the next phase to fostering the hydrogen economy will likely of the hydrogen fuel economy for buses, fleet vehicles, and ultimately personal vehicles. In order to demonstrateDEVELOPMENT OF A TURNKEY COMMERCIAL HYDROGEN FUELING STATION David E. Guro Air Products

  7. APPARENT WATER OPTICAL PROPERTIES AT THE CARIBBEAN TIME SERIES STATION

    E-Print Network [OSTI]

    Gilbes, Fernando

    APPARENT WATER OPTICAL PROPERTIES AT THE CARIBBEAN TIME SERIES STATION Roy A. Armstrong, Jose M of Puerto Rico MayagĂĽez, Puerto Rico 00681 ABSTRACT The Caribbean Time Series, located 28 nautical miles in near- surface waters of the northeastern Caribbean Basin. Apparent optical properties such as, remote

  8. Control of Volunteer Annual Sunflower Texas Agricultural Experiment Station -2000

    E-Print Network [OSTI]

    Mukhtar, Saqib

    Control of Volunteer Annual Sunflower Texas Agricultural Experiment Station - 2000 Brent Bean panhandle which require less water and less nitrogen to produce. As many corn fields will inevitably Center Amarillo, TX, E-mail: b-bean@tamu.edu and m-rowland #12;Table 1. Percent Volunteer Sunflower

  9. Mountain Lake Biological Station University of Virginia DISASTER PLAN

    E-Print Network [OSTI]

    Brodie III, Edmund D.

    . For all NON-EMERGENCY Disasters (minor accident, electrical failure, etc.) contact any MLBS staff member, lightning strikes, and power outages in and around the station. If a storm is approaching, take shelter immediately, secure doors and windows, and shutdown or unplug non-essential electrical equipment

  10. research in space Facilities on the International Space Station

    E-Print Network [OSTI]

    research in space Facilities on the International Space Station #12;1 #12;2 Table of Contents and Materials Research: 41 Fluid Physics, Crystal Growth, and External Test Beds Earth and Space Science (External and Internal): 51 Radiation, Thermal, Solar, and Geophysics ISS Control Centers 59 To Learn More

  11. An Overview of Energy-efficient Base Station Management Techniques

    E-Print Network [OSTI]

    Wichmann, Felix

    where users tend to exhibit similar behaviors, so that the load profile exhibits large variations. Unfortunately, this is not true: the power versus load profiles of base stations, and of the entire network performance maximization at full load. Indeed, the full load working condition is the most critical

  12. A summary of North American HVDC converter station reliability specifications

    SciTech Connect (OSTI)

    Vancers, I. (ABB Power Systems Inc., Los Angeles, CA (United States)); Hormozi, F.J. (Los Angeles Dept. of Water and Power, CA (United States))

    1993-07-01T23:59:59.000Z

    This paper summarizes Reliability, Availability, and Maintainability (RAM) specifications that were issued for thyristor based HVDC converter stations in service in North America. A total of twenty project specifications are summarized. A detailed summary by project is shown with specific quantitative requirements categorized. Definitions of terms, representative design principles, and formulas used in calculating RAM parameters contained in existing reliability specifications are presented.

  13. Ratios of heavy hadron semileptonic decay rates

    E-Print Network [OSTI]

    Michael Gronau; Jonathan L. Rosner

    2010-12-27T23:59:59.000Z

    Ratios of charmed meson and baryon semileptonic decay rates appear to be satisfactorily described by considering only the lowest-lying (S-wave) hadronic final states and assuming the kinematic factor describing phase space suppression is the same as that for free quarks. For example, the rate for $D_s$ semileptonic decay is known to be $(17.0 \\pm 5.3)%$ lower than those for $D^0$ or $D^+$, and the model accounts for this difference. When applied to hadrons containing $b$ quarks, this method implies that the $B_s$ semileptonic decay rate is about 1% higher than that of the nonstrange $B$ mesons. This small difference thus suggests surprisingly good local quark-hadron duality for $B$ semileptonic decays, complementing the expectation based on inclusive quark-hadron duality that these differences in rates should not exceed a few tenths of a percent. For $\\Lambda_b$ semileptonic decay, however, the inclusive rate is predicted to be about 13% greater than that of the nonstrange $B$ mesons. This value, representing a considerable departure from a calculation using a heavy quark expansion, is close to the corresponding experimental ratio $\\Gamma(\\Lambda_b)/ \\bar \\Gamma(B) = 1.13 \\pm 0.03$ of total decay rates.

  14. Hydraulic system for a ratio change transmission

    DOE Patents [OSTI]

    Kalns, Ilmars (Northville, MI)

    1981-01-01T23:59:59.000Z

    Disclosed is a drive assembly (10) for an electrically powered vehicle (12). The assembly includes a transaxle (16) having a two-speed transmission (40) and a drive axle differential (46) disposed in a unitary housing assembly (38), an oil-cooled prime mover or electric motor (14) for driving the transmission input shaft (42), an adapter assembly (24) for supporting the prime mover on the transaxle housing assembly, and a hydraulic system (172) providing pressurized oil flow for cooling and lubricating the electric motor and transaxle and for operating a clutch (84) and a brake (86) in the transmission to shift between the two-speed ratios of the transmission. The adapter assembly allows the prime mover to be supported in several positions on the transaxle housing. The brake is spring-applied and locks the transmission in its low-speed ratio should the hydraulic system fail. The hydraulic system pump is driven by an electric motor (212) independent of the prime mover and transaxle.

  15. Flexible Conversion Ratio Fast Reactor Systems Evaluation

    SciTech Connect (OSTI)

    Neil Todreas; Pavel Hejzlar

    2008-06-30T23:59:59.000Z

    Conceptual designs of lead-cooled and liquid salt-cooled fast flexible conversion ratio reactors were developed. Both concepts have cores reated at 2400 MWt placed in a large-pool-type vessel with dual-free level, which also contains four intermediate heat exchanges coupling a primary coolant to a compact and efficient supercritical CO2 Brayton cycle power conversion system. Decay heat is removed passively using an enhanced Reactor Vessel Auxiliary Cooling System and a Passive Secondary Auxiliary Cooling System. The most important findings were that (1) it is feasible to design the lead-cooled and salt-cooled reactor with the flexible conversion ratio (CR) in the range of CR=0 and CR=1 n a manner that achieves inherent reactor shutdown in unprotected accidents, (2) the salt-cooled reactor requires Lithium thermal Expansion Modules to overcme the inherent salt coolant's large positive coolant temperature reactivity coefficient, (3) the preferable salt for fast spectrum high power density cores is NaCl-Kcl-MgCl2 as opposed to fluoride salts due to its better themal-hydraulic and neutronic characteristics, and (4) both reactor, but attain power density 3 times smaller than that of the sodium-cooled reactor.

  16. Abundance ratios in hierarchical galaxy formation

    E-Print Network [OSTI]

    D. Thomas

    1999-01-18T23:59:59.000Z

    The chemical enrichment and stellar abundance ratios of galaxies which form in a hierarchical clustering scheme are calculated. For this purpose I adopt the star formation histories (SFH) as they are delivered by semi-analytic models in Kauffmann (1996}. It turns out that the average SFH of cluster ellipticals does not yield globally alpha-enhanced stellar populations. The star burst that occurs when the elliptical forms in the major merger plays therefore a crucial role in producing alpha-enhancement. Only under the assumption that the IMF is significantly flattened with respect to the Salpeter value during the burst, a Mg/Fe overabundant population can be obtained. In particular for the interpretation of radial gradients in metallicity and alpha-enhancement, the mixing of global and burst populations are of great importance. The model predicts bright field galaxies to be less alpha-enhanced than their counterparts in clusters.

  17. World's First Tri-Generation Fuel Cell and Hydrogen Fueling Station...

    Energy Savers [EERE]

    World's First Tri-Generation Fuel Cell and Hydrogen Fueling Station World's First Tri-Generation Fuel Cell and Hydrogen Fueling Station April 18, 2013 - 12:00am Addthis EERE...

  18. Fact #832: August 4, 2014 Over Half of the Refueling Stations...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    2: August 4, 2014 Over Half of the Refueling Stations in the U.S. and Canada Sell Diesel Fuel Fact 832: August 4, 2014 Over Half of the Refueling Stations in the U.S. and Canada...

  19. Navajo Generating Station and Air Visibility Regulations: Alternatives and Impacts

    SciTech Connect (OSTI)

    Hurlbut, D. J.; Haase, S.; Brinkman, G.; Funk, K.; Gelman, R.; Lantz, E.; Larney, C.; Peterson, D.; Worley, C.; Liebsch, E.

    2012-01-01T23:59:59.000Z

    Pursuant to the Clean Air Act, the U.S. Environmental Protection Agency (EPA) announced in 2009 its intent to issue rules for controlling emissions from Navajo Generating Station that could affect visibility at the Grand Canyon and at several other national parks and wilderness areas. The final rule will conform to what EPA determines is the best available retrofit technology (BART) for the control of haze-causing air pollutants, especially nitrogen oxides. While EPA is ultimately responsible for setting Navajo Generating Station's BART standards in its final rule, it will be the U.S. Department of the Interior's responsibility to manage compliance and the related impacts. This study aims to assist both Interior and EPA by providing an objective assessment of issues relating to the power sector.

  20. Optimal sequencing site of hydro-power stations

    SciTech Connect (OSTI)

    Hayashi, T.; Yoshino, F.; Waka, R. [Tottori Univ., Koyama (Japan). Dept. of Mechanical Engineering

    1995-06-01T23:59:59.000Z

    At the first stage of a hydro-power survey of a river, it is important to select the optimal hydro-power site. The most important condition to be satisfied is to determine the optimal site where the greatest and most economical amount of hydro-energy can be obtained. This paper proposes a new method in which the optimal arrangement of the hydro-power stations is determined by a computational operation using discrete data at points along the river such as the drainage area, altitude, and distance along the river channel as obtained from topographical maps instead of drawing on engineers` experiences and the intuitions of experts. The results by this method are then compared with data on existing hydro-power stations and the results planned by expert engineers to show that this new computational method is superior.

  1. p/pi Ratio in Di-Hadron Correlations

    E-Print Network [OSTI]

    Misha Veldhoen; for the ALICE Collaboration

    2012-10-08T23:59:59.000Z

    Particle ratios are important observables used to constrain models of particle production in heavy-ion collisions. In this work we report on a measurement of the p/pi ratio in the transverse momentum range 2.0 p_{T,assoc} p_{T,trig} p/pi ratio in the bulk region is compatible with the p/pi ratio of an inclusive measurement, and is much larger than the p/pi ratio in the jet peak. The p/pi ratio in the jet peak is compatible with a PYTHIA reference, in which fragmentation in the vacuum is the dominant mechanism of particle production.

  2. Development of Power-head based Fan Airflow Station

    E-Print Network [OSTI]

    Wang, G.; Liu, M.

    2005-01-01T23:59:59.000Z

    related to the measured fan speed. Actually the measured fan speed is assumed to equal the motor synchronous speed, which is proportional to the VFD frequency. Theoretically it is not true. The difference between the synchronous speed and motor speed... the basic theory, experiment and results of the power-head based airflow station. Theory Figure 1 shows variable speed fan connection schematic. VFD is normally installed on the motor to adjust the motor speed by modulating frequency. Typically...

  3. Lowry Range Solar Station: Arapahoe County, Colorado (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Yoder, M.; Andreas, A.

    A partnership with industry and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

  4. Nevada Power: Clark Station; Las Vegas, Nevada (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Stoffel, T.; Andreas, A.

    A partnership with the University of Nevada and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

  5. Review of the internship with Texas Agricultural Experiment Station

    E-Print Network [OSTI]

    Moen, Robert Allen

    1988-01-01T23:59:59.000Z

    at the Texas Agricultural Experiment Station at Sonora, Dr. Charles Taylor, Jr. , Mr. Terry Brooks and especially Mr. Nick Garza, Jr. with whom I worked extensively. TABLE OF COMTENIS Introduction Angora Goat Bonding Study Goat Bonding Procedure Field... (Soremouth vaccine), and Dr. Gory (Nutritional value of plants and animal nutrition), to name only a few. This tradition of quality research continues today. My main responsibility was to assist the research associates (Mr. Nick Garza and Mr. Terry Brooks...

  6. The history of College Station, Texas, 1938-1982

    E-Print Network [OSTI]

    Parks, Deborah Lynn

    1984-01-01T23:59:59.000Z

    , amid sparsely settled prairie and farmland. As a result of the school's iso- lation, administrators provided all facilities required by those connected with the college. The campus became a focal point around which a community developed... Station in 1938 when the growth of Texas A. and M. College precluded school officials from furnishing necessary facilities to residents as they had in the past. During the years of steady growth in the 1940's and 50's officials concentrated...

  7. Alternative Fuels Data Center: Compressed Natural Gas Fueling Stations

    Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data Center Home PageStationGreenhouse Gas (GHG)North CarolinaAFDC

  8. United States Department of Agriculture / Forest Service Rocky Mountain Research Station

    E-Print Network [OSTI]

    Flury, Markus

    United States Department of Agriculture / Forest Service Rocky Mountain Research Station Research Collins, CO: U.S. Department of Agriculture, Forest Service, Rocky Mountain Research Station. 8 p Sciences Laboratory of the Rocky Mountain Research Station (U.S. Department of Agriculture, Forest Service

  9. Report of Progress at the Troupe Sub-Station, Smith County Texas.

    E-Print Network [OSTI]

    Hotchkiss, W.S.

    1909-01-01T23:59:59.000Z

    TEXAS AGRICULTUR 146-409-lorn [PERIMENT STATIONS BULLETIN NO. 121 FEBRUARY 1, 1909 REPORT OF PROGRESS AT THE TROUPE SUB-STATION, SMITH COUNTY, TEXAS W. H. HOTCHKISS, SUPERINTENDENT IN CHARGE POSTOFFICE COLLEGE STATION, BRAZOS COUNTY.... ..................................... C. W. CRISLER. .Chief Clerk. .................................. F. R. N~VAILLE. .Stenographer. ...................................... A. S. WARE.. .Stenographer. STATE SUBSTATIONS. ..................... H. H. HARRINGTON, Director. .College...

  10. Locating PHEV exchange stations in V2G

    SciTech Connect (OSTI)

    Pan, Feng [Los Alamos National Laboratory; Bent, Russell [Los Alamos National Laboratory; Berscheid, Alan [Los Alamos National Laboratory; Izraelevitz, David [Los Alamos National Laboratory

    2010-01-01T23:59:59.000Z

    Plug-in hybrid electric vehicle (PREV) is an environment friendly modem transportation method and has been rapidly penetrate the transportation system. Renewable energy is another contributor to clean power but the associated intermittence increases the uncertainty in power generation. As a foreseen benefit of a vchicle-to-grid (V2G) system, PREV supporting infrastructures like battery exchange stations can provide battery service to PREV customers as well as being plugged into a power grid as energy sources and stabilizer. The locations of exchange stations are important for these two objectives under constraints from both ,transportation system and power grid. To model this location problem and to understand and analyze the benefit of a V2G system, we develop a two-stage stochastic program to optimally locate the stations prior to the realizations of battery demands, loads, and generation capacity of renewable power sources. Based on this model, we use two data sets to construct the V2G systems and test the benefit and the performance of these systems.

  11. IQ-Station: A Low Cost Portable Immersive Environment

    SciTech Connect (OSTI)

    Eric Whiting; Patrick O'Leary; William Sherman; Eric Wernert

    2010-11-01T23:59:59.000Z

    The emergence of inexpensive 3D TV’s, affordable input and rendering hardware and open-source software has created a yeasty atmosphere for the development of low-cost immersive environments (IE). A low cost IE system, or IQ-station, fashioned from commercial off the shelf technology (COTS), coupled with a targeted immersive application can be a viable laboratory instrument for enhancing scientific workflow for exploration and analysis. The use of an IQ-station in a laboratory setting also has the potential of quickening the adoption of a more sophisticated immersive environment as a critical enabler in modern scientific and engineering workflows. Prior work in immersive environments generally required either a head mounted display (HMD) system or a large projector-based implementation both of which have limitations in terms of cost, usability, or space requirements. The solution presented here provides an alternative platform providing a reasonable immersive experience that addresses those limitations. Our work brings together the needed hardware and software to create a fully integrated immersive display and interface system that can be readily deployed in laboratories and common workspaces. By doing so, it is now feasible for immersive technologies to be included in researchers’ day-to-day workflows. The IQ-Station sets the stage for much wider adoption of immersive environments outside the small communities of virtual reality centers.

  12. Lectures on Applied Mathematics Part 1: Linear Algebra

    E-Print Network [OSTI]

    Bowen, Ray M.

    2014-01-22T23:59:59.000Z

    LECTURES ON APPLIED MATHEMATICS Part 1: Linear Algebra Ray M. Bowen Professor Emeritus of Mechanical Engineering President Emeritus Texas A&M University College Station, Texas Copyright Ray... M. Bowen Updated January, 2014 ii ____________________________________________________________________________ PREFACE To Part 1 It is common for Departments of Mathematics to offer a junior-senior level course on Linear Algebra...

  13. Sex ratios in the rodent malaria parasite, Plasmodium chabaudi 

    E-Print Network [OSTI]

    Reece, S E; Duncan, Alison B; West, Stuart A; Read, Andrew F

    2003-01-01T23:59:59.000Z

    The sex ratios of malaria and related Apicomplexan parasites play a major role in transmission success. Here, we address 2 fundamental issues in the sex ratios of the rodent malaria parasite, Plasmodium chabaudi. First we ...

  14. Ultra-short nacelles for low fan pressure ratio propulsors

    E-Print Network [OSTI]

    Peters, Andreas, Ph. D. Massachusetts Institute of Technology

    2014-01-01T23:59:59.000Z

    This thesis addresses the uncharted inlet and nacelle design space for low pressure ratio fans for advanced aeroengines. A key feature in low fan pressure ratio (FPR) propulsors with short inlets and nacelles is the increased ...

  15. Butler Hibben Princeton Grad Lawrence Wegmans Wegmans Walmart Trader Butler Apts Magie Station College Apts (arrive) (depart) Joe's Apts

    E-Print Network [OSTI]

    Bou-Zeid, Elie

    Butler Hibben Princeton Grad Lawrence Wegmans Wegmans Walmart Trader Butler Apts Magie Station Wegmans Wegmans Walmart Trader Butler Apts Magie Station College Apts (arrive) (depart) Joe's Apts

  16. Determination of a peak benzene exposure to consumers at typical self-service gasoline stations

    E-Print Network [OSTI]

    Carapezza, Ted

    1977-01-01T23:59:59.000Z

    the public exposure to benzene at the self-serv1ce gas pump seems of paramount importance dur1ng this time of the highly publicized benzene hazard and increased gasoline consumption. These factors produced the amtivating effect for th1s research effort wh... Table ~Pa e I. HUMAN INHALATION EXPOSURE TO GASOLINE VAPOR. I I. SELF-SERVICE GASOLINE STATIONS . III. SAMPLING RESULTS IV. FIELD DATA: STATION I V. FIELD DATA: STATION II VI. FIEI D DATA: STATION III. VI I. FIELD DATA: STATION IV . VIII...

  17. GLOBAL STABILITY STUDY OF THE ULTRALOW ASPECT RATIO TOKAMAK,

    E-Print Network [OSTI]

    LETTERS GLOBAL STABILITY STUDY OF THE ULTRALOW ASPECT RATIO TOKAMAK, ULART M. YAMADA, N. POMPHREY of the TS-3device at Tokyo Univesity, ultralow aspect ratio tokamak (ULART) configurations have been of the tiltishift modes agree well with the TS-3 data. 1. INTRODUCTION In recent years, low aspect ratio tokamak

  18. accelerating rf station: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    designed as 450 Omega . The RF power is fed by 1 kW solid state amplifier using a step-up transformer with 1:9 impedance ratio. In the high power test, an accelerating gap voltage...

  19. Vehicles and E85 Stations Needed to Achieve Ethanol Goals

    SciTech Connect (OSTI)

    Greene, David L [ORNL

    2008-01-01T23:59:59.000Z

    This paper presents an analysis of the numbers of stations and vehicles necessary to achieve future goals for sales of ethanol fuel (E85). The paper does not analyze issues related to the supply of ethanol which may turn out to be of even greater concern. A model of consumers decisions to purchase E85 versus gasoline based on prices, availability, and refueling frequency is derived and preliminary results for 2010, 2017 and 2030 consistent with the President s 2007 biofuels program goals are presented (1). A limited sensitivity analysis is carried out to indicate key uncertainties in the trade-off between the number of stations and fuels. The analysis indicates that to meet a 2017 goal of 26 billion gallons of E85 sold, on the order of 30% to 80% of all stations may need to offer E85, and that 125 to 200 million flexible fuel vehicles (FFVs) may need to be on the road, even if oil prices remain high. These conclusions are tentative for three reasons: (1) there is considerable uncertainty about key parameter values, such as the price elasticity of choice between E85 and gasoline, (2) the future prices of E85 and gasoline are uncertain; and (3) the method of analysis used is highly aggregated; it does not consider the potential benefits of regional strategies nor the possible existence of market segments predisposed to purchase E85. Nonetheless, the preliminary results indicate that the 2017 biofuels program goals are ambitious and will require a massive effort to produce FFVs and insure widespread availability of E85.

  20. A High-Altitude, Station-Keeping Astronomical Platform

    E-Print Network [OSTI]

    Robert A. Fesen

    2006-06-15T23:59:59.000Z

    Several commercial telecommunication ventures together with a well funded US military program make it a likely possibility that an autonomous, high-altitude, light-than-air (LTA) vehicle which could maneuver and station-keep for weeks to many months will be a reality in a few years. Here I outline how this technology could be used to develop a high-altitude astronomical observing platform which could return high-resolution optical data rivaling those from space-based platforms but at a fraction of the cost.

  1. A High-Altitude, Station-Keeping Astronomical Platform

    E-Print Network [OSTI]

    Fesen, R A

    2006-01-01T23:59:59.000Z

    Several commercial telecommunication ventures together with a well funded US military program make it a likely possibility that an autonomous, high-altitude, light-than-air (LTA) vehicle which could maneuver and station-keep for weeks to many months will be a reality in a few years. Here I outline how this technology could be used to develop a high-altitude astronomical observing platform which could return high-resolution optical data rivaling those from space-based platforms but at a fraction of the cost.

  2. No loss fueling station for liquid natural gas vehicles

    SciTech Connect (OSTI)

    Cieslukowski, R.E.

    1992-06-16T23:59:59.000Z

    This patent describes a no loss fueling station for delivery of liquid natural gas (LNG) to a use device such as a motor vehicle. It comprises: a pressure building tank holding a quantity of LNG and gas head; means for delivering LNG to the pressure building tank; means for selectively building the pressure in the pressure building tank; means for selectively reducing the pressure in the pressure building tank; means for controlling the pressure building and pressure reducing means to maintain a desired pressure in the pressure building tank without venting natural gas to the atmosphere; and means for delivering the LNG from the pressure building tank to the use device.

  3. Hydrogen Fueling Station in Honolulu, Hawaii Feasibility Analysis

    SciTech Connect (OSTI)

    Porter Hill; Michael Penev

    2014-08-01T23:59:59.000Z

    The Department of Energy Hydrogen & Fuel Cells Program Plan (September 2011) identifies the use of hydrogen for government and fleet electric vehicles as a key step for achieving “reduced greenhouse gas emissions; reduced oil consumption; expanded use of renewable power …; highly efficient energy conversion; fuel flexibility …; reduced air pollution; and highly reliable grid-support.” This report synthesizes several pieces of existing information that can inform a decision regarding the viability of deploying a hydrogen (H2) fueling station at the Fort Armstrong site in Honolulu, Hawaii.

  4. Optimal design of AC filter circuits in HVDC converter stations

    SciTech Connect (OSTI)

    Saied, M.M.; Khader, S.A. [Kuwait Univ. (Kuwait). Electrical and Computer Engineering Dept.

    1995-12-31T23:59:59.000Z

    This paper investigates the reactive power as well as the harmonic conditions on both the valve and the AC-network sides of a HVDC converter station. The effect of the AC filter circuits is accurately modeled. The program is then augmented by adding an optimization routine. It can identify the optimal filter configuration, yielding the minimum current distortion factor at the AC network terminals for a prespecified fundamental reactive power to be provided by the filter. Several parameter studies were also conducted to illustrate the effect of accidental or intentional deletion of one of the filter branches.

  5. Hellisheidi Geothermal Power Station - South Iceland | Open Energy

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are8COaBulkTransmissionSitingProcess.pdfGetec AG|InformationInformation Station - South Iceland Jump to:

  6. Huntington Station, New York: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are8COaBulkTransmissionSitingProcess.pdfGetecGtel JumpCounty, Texas: Energy Resources JumpHuntingStation, New York:

  7. Elk City Station Biomass Facility | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model,DOEHazel Crest, Illinois:EdinburghEldoradoElectronVaultStation Biomass Facility

  8. Alternative Fuels Data Center: Ethanol Fueling Station Locations

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office511041cloth DocumentationProductsAlternative Fuels Clean CitiesStation Locations to someone by E-mail

  9. Alternative Fuels Data Center: Green Fueling Station Powers Fleets in

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office511041cloth DocumentationProductsAlternative Fuels Clean CitiesStationTrucks GoldenUpstate New

  10. Alternative Fuels Data Center: Hydrogen Fueling Station Locations

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office511041cloth DocumentationProductsAlternative Fuels Clean CitiesStationTrucksRidesHydrogen

  11. Alternative Fuels Data Center: Natural Gas Fueling Station Locations

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office511041cloth DocumentationProductsAlternative Fuels CleanReduce OperatingPropaneStation Locations to

  12. Alternative Fuels Data Center: Propane Fueling Station Locations

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office511041cloth DocumentationProductsAlternative Fuels CleanReduceNew HampshirePropane BusesStation

  13. Alternative Fuels Data Center: About the Alternative Fueling Station Data

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625govInstrumentstdmadapInactiveVisiting the TWP TWP RelatedCellulase C.Tier 2 andIndependence andStateLocate Stations

  14. Rancia 2 Geothermal Power Station | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro Industries Pvt Ltd Jump to: navigation, search Name:Rancia 2 Geothermal Power Station Jump to:

  15. A prototype station for ARIANNA: a detector for cosmic neutrinos

    E-Print Network [OSTI]

    Lisa Gerhardt; Spencer R. Klein; Thorsten Stezelberger; Steve Barwick; Kamlesh Dookayka; Jordan Hanson; Ryan Nichol

    2010-05-27T23:59:59.000Z

    The Antarctic Ross Iceshelf Antenna Neutrino Array (ARIANNA) is a proposed detector for ultra-high energy astrophysical neutrinos. It will detect coherent radio Cherenkov emission from the particle showers produced by neutrinos with energies above about 10^17 eV. ARIANNA will be built on the Ross Ice Shelf just off the coast of Antarctica, where it will eventually cover about 900 km^2 in surface area. There, the ice-water interface below the shelf reflects radio waves, giving ARIANNA sensitivity to downward going neutrinos and improving its sensitivity to horizontally incident neutrinos. ARIANNA detector stations will each contain 4-8 antennas which search for brief pulses of 50 MHz to 1 GHz radio emission from neutrino interactions. We describe a prototype station for ARIANNA which was deployed in Moore's Bay on the Ross Ice Shelf in December 2009, discuss the design and deployment, and present some initial figures on performance. The ice shelf thickness was measured to be 572 +/- 6 m at the deployment site.

  16. Adjusting flow station job to remote Nigerian location yields savings

    SciTech Connect (OSTI)

    Wooten, R.; Williams, E.C. (OPI International Inc., Houston, TX (United States))

    1994-05-02T23:59:59.000Z

    In September 1991, Chevron Nigeria Ltd. and Nigerian National Petroleum Crop. contracted Offshore Pipelines to design, procure, construct, install, and commission the Opuekeba 30,000 b/d crude-oil flow station on an offshore platform near Olero Creek, Nigeria, approximately 22 miles from the nearest deepwater access. Chevron's original project plan included bringing the flow station to the site in small packages and then assembling it in a lengthy field hook-up process. Offshore Pipelines developed a plan early in the project to maximize construction and hook-up in the fabrication yard, then transport the nearly complete structures to site by way of a newly dredged canal. What proved to be most difficult was the site location in Nigeria. Job planning and communication were important in the successful completion of the project. Keeping the components of the large and complex facility simple proved to be effective and efficient and played a key role in completing the project on time and within budget. The paper discusses overcoming obstacles, lift and depth constraints, dredging, fabrication, installation, and large-time problems.

  17. A prototype station for ARIANNA: a detector for cosmic neutrinos

    SciTech Connect (OSTI)

    Gerhardt, L.; Klein, S.; Stezelberger, T.; Barwick, S.; Dookayka, K.; Hanson, J.; Nichol, R.

    2010-05-27T23:59:59.000Z

    The Antarctic Ross Iceshelf Antenna Neutrino Array (ARIANNA) is a proposed detector for ultra-high energy astrophysical neutrinos. It will detect coherent radio Cherenkov emission from the particle showers produced by neutrinos with energies above about 1017 eV. ARIANNA will be built on the Ross Ice Shelf just off the coast of Antarctica, where it will eventually cover about 900 km2 in surface area. There, the ice-water interface below the shelf reflects radio waves, giving ARIANNA sensitivity to downward going neutrinos and improving its sensitivity to horizontally incident neutrinos. ARIANNA detector stations will each contain 4-8 antennas which search for brief pulses of 50 MHz to 1 GHz radio emission from neutrino interactions. We describe a prototype station for ARIANNA which was deployed in Moore's Bay on the Ross Ice Shelf in December 2009, discuss the design and deployment, and present some initial figures on performance. The ice shelf thickness was measured to be 572 +- 6 m at the deployment site.

  18. Sibley station low-sulfur coal conversion program

    SciTech Connect (OSTI)

    Rupinskas, R.L. [Sargent & Lundy LLC, Chicago, IL (United States); Rembold, D.F. [Missouri Public Service, Kansas City, MO (United States)

    1995-03-01T23:59:59.000Z

    After embarking on an upgrade project in 1986 that was designed to allow efficient and reliable operation of its coal-fired Sibley station through 2010, Missouri Public Service (MPS) faced the uncertainty of impending acid-rain legislation. To protect its investment in the Sibley Rebuild Program, the utility evaluated compliance options based on the emerging legislation and concluded that switching to low-sulfur coal offered the least-cost compliance approach. Compared to installing a scrubber, switching to a low-sulfur coal was also more straightforward, although not without challenges and complications. This paper reviews the Sibley low-sulfur coal conversion program. At Sibley, fuel switching was chosen only after numerous internal and external studies; it withstood late challenges from natural gas and allowance trading. Switching demanded additional equipment to blend Power River Basin coals and other coals, and demanded additional and upgraded protective equipment in the areas of fire protection, dust collection, and explosion prevention. In the year since the coal conversion project was completed the facility has operated reliably, the economic benefits of the lower cost Powder River Basin coals have been realized, and the station has also met the requirements of both phases of the acid rain legislation. Fuel switching at Sibley required a team approach and careful analysis. The coal conversion project also required attention and dedication by team members in order to minimize fuel costs while maintaining optimum plant efficiency and availability.

  19. Observation of Enhanced Transformer Ratio in Collinear Wakefield Acceleration

    SciTech Connect (OSTI)

    Jing, C.; Kanareykin, A.; Schoessow, P. [Euclid Techlabs LLC, Solon, Ohio 44139 (United States); Power, J. G.; Conde, M.; Yusof, Z.; Gai, W. [High Energy Physics Division, Argonne National Laboratory, Argonne, Illinois-60439 (United States)

    2007-04-06T23:59:59.000Z

    One approach to future high energy particle accelerators is based on the wakefield principle: a leading high-charge drive bunch is used to excite fields in an accelerating structure or plasma that in turn accelerates a trailing low-charge witness bunch. The transformer ratio R is defined as the ratio of the maximum energy gain of the witness bunch to the maximum energy loss of the drive bunch. In general, R<2 for this configuration. A number of techniques have been proposed to overcome the transformer ratio limitation. We report here the first experimental study of the ramped bunch train (RBT) technique in a dielectric based accelerating structure. A single drive bunch was replaced by two bunches with charge ratio of 1 ratio 2.5 and a separation of 10.5 wavelengths of the fundamental mode. An average measured transformer ratio enhancement by a factor of 1.31 over the single drive bunch case was obtained.

  20. Dual equilibrium in a finite aspect ratio tokamak

    E-Print Network [OSTI]

    Gourdain, P A

    2008-01-01T23:59:59.000Z

    achievable in conventional tokamaks. Previous research hasin a ?nite aspect ratio tokamak P. -A. Gourdain a , b ,? ,fusion reactor is the tokamak concept, a closed magnetic

  1. Neutrino Flavor Ratios Modified by Cosmic Ray Re-acceleration

    E-Print Network [OSTI]

    Kawanaka, Norita

    2015-01-01T23:59:59.000Z

    Re-acceleration of $\\pi$'s and $\\mu$'s modifies the flavor ratio at Earth (at astrophysical sources) of neutrinos produced by $\\pi$ decay, $\

  2. aspect ratio spherical: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Stability Modes of Low-Aspect-Ratio Wings Matt Shields Engineering Websites Summary: vehicles (MAVs) ranging from flexiblemorphing wing aircraft to nano- and pico-scale...

  3. aspect ratio toroidal: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Stability Modes of Low-Aspect-Ratio Wings Matt Shields Engineering Websites Summary: vehicles (MAVs) ranging from flexiblemorphing wing aircraft to nano- and pico-scale...

  4. aerosol ratio program: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    contribute a major portion of atmospheric aerosol mass loading 5. The estimated global annual Liou, K. N. 2 Studying Clouds and Aerosols with Lidar Depolarization Ratio and...

  5. aspect ratio aluminium: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    perturbations Reynolds numbers Re) by means of the minimal amplitude of an initial global perturbation triggering Meseguer, Alvaro 9 Effect of mineral dust aerosol aspect ratio...

  6. Oxygen And Carbon Isotope Ratios Of Hydrothermal Minerals From...

    Open Energy Info (EERE)

    Oxygen And Carbon Isotope Ratios Of Hydrothermal Minerals From Yellowstone Drill Cores Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Oxygen...

  7. High Compression Ratio Turbo Gasoline Engine Operation Using...

    Broader source: Energy.gov (indexed) [DOE]

    Compression Ratio Turbo Gasoline Engine Operation Using Alcohol Enhancement PI: John B. Heywood Sloan Automotive Laboratory Massachusetts Institute of Technology June 19, 2014...

  8. Regulations, Codes, and Standards (RCS) Template for California Hydrogen Dispensing Stations

    SciTech Connect (OSTI)

    Rivkin, C.; Blake, C.; Burgess, R.; Buttner, W.; Post, M.

    2012-11-01T23:59:59.000Z

    This report explains the Regulations, Codes, and Standards (RCS) requirements for hydrogen dispensing stations in the State of California. The reports shows the basic components of a hydrogen dispensing station in a simple schematic drawing; the permits and approvals that would typically be required for the construction and operation of a hydrogen dispensing station; and a basic permit that might be employed by an Authority Having Jurisdiction (AHJ).

  9. Radio Frequency Station - Beam Dynamics Interaction in Circular Accelerators

    SciTech Connect (OSTI)

    Mastoridis, Themistoklis; /Stanford U., Elect. Eng. Dept. /SLAC

    2011-03-01T23:59:59.000Z

    The longitudinal beam dynamics in circular accelerators is mainly defined by the interaction of the beam current with the accelerating Radio Frequency (RF) stations. For stable operation, Low Level RF (LLRF) feedback systems are employed to reduce coherent instabilities and regulate the accelerating voltage. The LLRF system design has implications for the dynamics and stability of the closed-loop RF systems as well as for the particle beam, and is very sensitive to the operating range of accelerator currents and energies. Stability of the RF loop and the beam are necessary conditions for reliable machine operation. This dissertation describes theoretical formalisms and models that determine the longitudinal beam dynamics based on the LLRF implementation, time domain simulations that capture the dynamic behavior of the RF station-beam interaction, and measurements from the Positron-Electron Project (PEP-II) and the Large Hadron Collider (LHC) that validate the models and simulations. These models and simulations are structured to capture the technical characteristics of the system (noise contributions, non-linear elements, and more). As such, they provide useful results and insight for the development and design of future LLRF feedback systems. They also provide the opportunity to study diverse longitudinal beam dynamics effects such as coupled-bunch impedance driven instabilities and single bunch longitudinal emittance growth. Coupled-bunch instabilities and RF station power were the performance limiting effects for PEP-II. The sensitivity of the instabilities to individual LLRF parameters, the effectiveness of alternative operational algorithms, and the possible tradeoffs between RF loop and beam stability were studied. New algorithms were implemented, with significant performance improvement leading to a world record current during the last PEP-II run of 3212 mA for the Low Energy Ring. Longitudinal beam emittance growth due to RF noise is a major concern for LHC. Simulations studies and measurements were conducted that clearly show the correlation between RF noise and longitudinal bunch emittance, identify the major LLRF noise contributions, and determine the RF component dominating this effect. With these results, LHC upgrades and alternative algorithms are evaluated to reduce longitudinal emittance growth during operations. The applications of this work are described with regard to future machines and analysis of new technical implementations, as well as to possible future work which would continue the directions of this dissertation.

  10. Vision for Rollout of Fuel Cell Vehicles and Hydrogen Fuel Stations...

    Broader source: Energy.gov (indexed) [DOE]

    document establishes the California Fuel Cell Partnership's current consensus vision of next steps for vehicles and hydrogen stations in California. 200707completevisiondeployme...

  11. attract-and-kill bait stations: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    MRF 2000 paste bait Boric acid Gentrol Point Source Station (IGR) Hydroprene Dusts Silica aerogel or boric acid Compressed air flushing agent air Carpenter Virginia Tech 100...

  12. Hydrogen Energy Stations: Poly-Production of Electricity, Hydrogen, and Thermal Energy

    E-Print Network [OSTI]

    Lipman, Timothy; Brooks, Cameron

    2006-01-01T23:59:59.000Z

    Partnership Finalizes Hydrogen Energy Roadmap,” World WideCommercialization Strategy for Hydrogen Energy Technologies,Economic Analysis of Hydrogen Energy Station Concepts: Are “

  13. Uncertainty for Satellite and Station Solar Data in the Updated NSRDB

    SciTech Connect (OSTI)

    Myers, D. R.

    2008-10-29T23:59:59.000Z

    Solar Resource Assessment Workshop, Denver CO, Oct 29, 2008 presentation: Uncertainty for Satellite and Station Solar Data in the Updated NSRDB,

  14. Acceptance test report, 241-AW air inlet filter station pressure decay test

    SciTech Connect (OSTI)

    Tuck, J.A.

    1996-02-21T23:59:59.000Z

    This is the acceptance test report for pressure decay tests performed on newly-installed 241-AW Tank Farm primary ventilation system air inlet filter stations.

  15. Converting Limbo Lands to Energy-Generating Stations: Renewable Energy Technologies on Underused, Formerly Contaminated Sites

    SciTech Connect (OSTI)

    Mosey, G.; Heimiller, D.; Dahle, D.; Vimmerstedt, L.; Brady-Sabeff, L.

    2007-10-01T23:59:59.000Z

    This report addresses the potential for using 'Limbo Lands' (underused, formerly contaminated sites, landfills, brownfields, abandoned mine lands, etc. ) as sites for renewable energy generating stations.

  16. Bibliography on overvoltage protection and insulation coordination of HVDC converter stations, 1979-1989

    SciTech Connect (OSTI)

    Not Available

    1991-04-01T23:59:59.000Z

    This bibliography is a listing of references on the subject of overvoltage protection and insulation coordination of HVDC converter stations, for the years 1979 through 1989.

  17. SNL Issues a Request for Quotation for a Hydrogen Station Test...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    for Quotation for a Hydrogen Station Test Device DOE Issues Request for Quotations for Depleted Uranium Hexafluoride Conversion Technical Services 10 Questions Regarding SAE...

  18. Next Generation Hydrogen Station Composite Data Products: Data through Quarter 2 of 2013

    SciTech Connect (OSTI)

    Sprik, S.; Kurtz, J.; Ainscough, C.; Post, M.; Saur, G.; Peters, M.

    2013-11-01T23:59:59.000Z

    This report includes 18 composite data products (CDPs) produced for next generation hydrogen stations, with data through quarter 2 of 2013.

  19. Next Generation Hydrogen Station Composite Data Products: Data through Quarter 4 of 2013

    SciTech Connect (OSTI)

    Sprik, S.; Kurtz, J.; Peters, M.

    2014-05-01T23:59:59.000Z

    This report includes 25 composite data products (CDPs) produced for next generation hydrogen stations, with data through quarter 4 of 2013.

  20. Technical Analysis of the Hydrogen Energy Station Concept, Phase I and Phase II

    SciTech Connect (OSTI)

    TIAX, LLC

    2005-05-04T23:59:59.000Z

    Phase I Due to the growing interest in establishing a domestic hydrogen infrastructure, several hydrogen fueling stations already have been established around the country as demonstration units. While these stations help build familiarity with hydrogen fuel in their respective communities, hydrogen vehicles are still several years from mass production. This limited number of hydrogen vehicles translates to a limited demand for hydrogen fuel, a significant hurdle for the near-term establishment of commercially viable hydrogen fueling stations. By incorporating a fuel cell and cogeneration system with a hydrogen fueling station, the resulting energy station can compensate for low hydrogen demand by providing both hydrogen dispensing and combined heat and power (CHP) generation. The electrical power generated by the energy station can be fed back into the power grid or a nearby facility, which in turn helps offset station costs. Hydrogen production capacity not used by vehicles can be used to support building heat and power loads. In this way, an energy station can experience greater station utility while more rapidly recovering capital costs, providing an increased market potential relative to a hydrogen fueling station. At an energy station, hydrogen is generated on-site. Part of the hydrogen is used for vehicle refueling and part of the hydrogen is consumed by a fuel cell. As the fuel cell generates electricity and sends it to the power grid, excess heat is reclaimed through a cogeneration system for use in a nearby facility. Both the electrical generation and heat reclamation serve to offset the cost of purchasing the equivalent amount of energy for nearby facilities and the energy station itself. This two-phase project assessed the costs and feasibility of developing a hydrogen vehicle fueling station in conjunction with electricity and cogenerative heat generation for nearby Federal buildings. In order to determine which system configurations and operational patterns would be most viable for an energy station, TIAX developed several criteria for selecting a representative set of technology configurations. TIAX applied these criteria to all possible technology configurations to determine an optimized set for further analysis, as shown in Table ES-1. This analysis also considered potential energy station operational scenarios and their impact upon hydrogen and power production. For example, an energy station with a 50-kWe reformer could generate enough hydrogen to serve up to 12 vehicles/day (at 5 kg/fill) or generate up to 1,200 kWh/day, as shown in Figure ES-1. Buildings that would be well suited for an energy station would utilize both the thermal and electrical output of the station. Optimizing the generation and utilization of thermal energy, hydrogen, and electricity requires a detailed look at the energy transfer within the energy station and the transfer between the station and nearby facilities. TIAX selected the Baseline configuration given in Table ES-1 for an initial analysis of the energy and mass transfer expected from an operating energy station. Phase II The purpose of this technical analysis was to analyze the development of a hydrogen-dispensing infrastructure for transportation applications through the installation of a 50-75 kW stationary fuel cell-based energy station at federal building sites. The various scenarios, costs, designs and impacts of such a station were quantified for a hypothetical cost-shared program that utilizes a natural gas reformer to provide hydrogen fuel for both the stack(s) and a limited number of fuel cell powered vehicles, with the possibility of using cogeneration to support the building heat load.

  1. EIS-0215: Pinon Pine Power Project, Tracy Station, NV

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy (DOE) prepared this statement to assess the environmental and human health issues associated with the Pinon Pine Power Project, a proposed demonstration project that would be cost-shared by DOE and the Sierra Pacific Power Company (SPPCo.) under DOE's Clean Coal Technology Program. The proposed Federal action is for DOE to provide cost-shared funding support for the construction and operation of the Pinon Pine Power Project, a coal-fired power generating facility, which would be a nominal, 800-ton-per-day (104 megawatt (MW) gross generation) air-blown, Integrated Gasification Combined-Cycle plant proposed by SPPCo. at its Tracy Power Station near Reno, Nevada.

  2. Monitoring and optimization of energy consumption of base transceiver stations

    E-Print Network [OSTI]

    Spagnuolo, Antonio; Vetromile, Carmela; Formosi, Roberto; Lubritto, Carmine

    2015-01-01T23:59:59.000Z

    The growth and development of the mobile phone network has led to an increased demand for energy by the telecommunications sector, with a noticeable impact on the environment. Monitoring of energy consumption is a great tool for understanding how to better manage this consumption and find the best strategy to adopt in order to maximize reduction of unnecessary usage of electricity. This paper reports on a monitoring campaign performed on six Base Transceiver Stations (BSs) located central Italy, with different technology, typology and technical characteristics. The study focuses on monitoring energy consumption and environmental parameters (temperature, noise, and global radiation), linking energy consumption with the load of telephone traffic and with the air conditioning functions used to cool the transmission equipment. Moreover, using experimental data collected, it is shown, with a Monte Carlo simulation based on power saving features, how the BS monitored could save energy.

  3. Review of the Limerick Generating Station Probabilistic Risk Assessment

    SciTech Connect (OSTI)

    Papazoglou, I.A.; Karol, R.; Shiu, K.; Fiarman, S.; Lederman, L.; Ludewig, H.; Pratt, W.T.; Bari, R.A.

    1983-02-01T23:59:59.000Z

    A review of the Probabilistic Risk Assessment of the Limerick Generating Station was conducted with the broad objective of evaluating its risks in relation to those identified in the Reactor Safety Study (WASH-1400). The review included a technical assessment of the assumptions and methods used in the Limerick study. It also included a re-evaluation of the main results within the scope and general methodological framework of the study. This included both qualitative and quantitative analyses of accident initiators, data bases, accident sequences which result in core damage, core melt phenomena, fission product behavior, and offsite consequences. Specific comparisons were made between the Limerick study, the Brookhaven review, and the WASH-1400 reactor for the core damage frequency and the average frequencies of acute and latent fatalities. The effect of uncertainties was considered throughout the review process and the uncertainty bands for the risk indices were quantified.

  4. Low-Cost Methane Liquefaction Plant and Vehicle Refueling Station

    SciTech Connect (OSTI)

    B. Wilding; D. Bramwell

    1999-01-01T23:59:59.000Z

    The Idaho National Engineering and Environmental Laboratory (INEEL) is currently negotiating a collaborative effort with Pacific Gas and Electric (PG&E) that will advance the use of liquefied natural gas (LNG) as a vehicle fuel. We plan to develop and demonstrate a small-scale methane liquefaction plant (production of 5,000 to 10,000 gallons per day) and a low-cost ($150,000) LNG refueling station to supply fuel to LNG-powered transit buses and other heavy-duty vehicles. INEEL will perform the research and development work. PG&E will deploy the new facilities commercially in two demonstration projects, one in northern California, and one in southern California.

  5. Field Tests with Corn at College Station and Beeville.

    E-Print Network [OSTI]

    Pittuck, B. C.; Connell, J. H.

    1898-01-01T23:59:59.000Z

    . . . 4.13 4.69 2.87 * 4.04 2.33 5.33 1.77 2.62 4.43 R ain fa ll in inches for J u ly .................. 2.47 .45 1.36 .75 .45 1.64 1.51 .48 1.45 2.60 Rain fa ll in inches for A u gu stf .......... 1.19 .75 .09 3.99 1.85 7.01 2.81 .60 4.68 .21 * Data... inches in the drill. 2. V arie ty and D istance Test?Embracing 5 varieties, th e d istance varying between rows from 3 feet to 5 feet, and 2 1-2 feet to 3 feet in the drill. SUMMARY OF RESULTS. COLLEGE STATION. Varieties?W ith th e varie...

  6. Ridge station eases Florida's waste-disposal problems

    SciTech Connect (OSTI)

    Swanekamp, R.

    1994-10-01T23:59:59.000Z

    Two results of Florida's continuing population growth are (1) a critical need for electricity, and (2) a solid-waste disposal crisis. During a recent winter cold snap, electric demand in one service territory surged 25% over generating capacity and 10% over net system capability. Rolling blackouts ensued. At the same time, Florida's fragile wetlands environment is suffering from years of unfettered development. Groundwater sources are contaminated, landfill space is scarce, and illegal tire dumps blight the landscape. The recently constructed Ridge generating station in Polk County, Fla. is addressing both the state's electrical and environmental needs. Ridge, which entered commercial operation in May, burns a unique mix of urban woodwaste and scrap tires to provide 45 MW of critically needed electricity while keeping large quantities of solid waste out of landfills. When pipeline construction at an adjacent landfill is completed, the facility also will burn the methane gases produced when garbage decomposes.

  7. ITER physics design guidelines at high aspect ratio

    SciTech Connect (OSTI)

    Uckan, N.A.

    1991-01-01T23:59:59.000Z

    The physics requirements for ITER design are formulated in a set of physics design guidelines. These guidelines, established by the ITER Physics Group during the Conceptual Design Activity (CDA, 1988--90), were based on credible extrapolations of the tokamak physics database as assessed during the CDA, and defined a class of tokamak designs (with plasma current I {approximately}20 MA and aspect ratio A {approximately}2.5--3.5) that meet the ITER objectives. Recent US studies have indicated that there may be significant benefits if the ITER-CDA design point is moved from the low aspect ratio, high current baseline (A = 2.79, I = 22 MA) to a high aspect ratio machine at A {approximately}4, I {approximately}15 MA, especially regarding steady-state, technology-testing performance. To adequately assess the physics and technology testing capability of higher aspect ratio design options, several changes are proposed to the original ITER guidelines to reflect the latest (although limited) developments in physics understanding at higher aspect ratios. The critical issues for higher aspect ratio design options are the uncertainty in scaling of confinement with aspect ratio, the variation of vertical stability with elongation and aspect ratio, plasma shaping requirements, ability to control and maintain plasma current and q-profiles for MHD stability (and volt-second consumption), access for current drive, restrictions on field ripple and divertor plate incident angles, etc. 5 refs., 1 tab.

  8. IEA Workshop 59 Shape and Aspect Ratio Optimization for

    E-Print Network [OSTI]

    IEA Workshop 59 Shape and Aspect Ratio Optimization for High Beta, Steady-State Tokamak SCOPE and aspect ratio is particularly important for achieving high beta and also for the optimization of edge optimization of high beta steady state tokamak including DEMO concept, stability and CD assessment

  9. Net energy ratio of photobiohydrogen generation G. Burgessa

    E-Print Network [OSTI]

    Net energy ratio of photobiohydrogen generation G. Burgessa and J.G. Fernández the energy content, the operational energy inputs, and the net energy ratio (NER) of an industrial tubular photobioreactor used for the photosynthetic production of H2 by microalgae. The calculated H2 output

  10. aspect ratio hydrogen: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    aspect ratio hydrogen First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Balanced Aspect Ratio Trees...

  11. Successes and failures in using the ambient ratio method to estimate annual NO{sub 2} impacts

    SciTech Connect (OSTI)

    Chico, T. [South Coast AQMD, Diamond Bar, CA (United States); Wong, H. [Hawaii State Dept. of Health, Honolulu, HI (United States); Schuler, A. [Alaska Dept. of Environmental Conservation, Juneau, AK (United States)

    1998-12-31T23:59:59.000Z

    At the 84th Annual Meeting of the A and WMA in 1991, Chu and Meyer proposed an alternative to the ozone limiting method (OLM) for estimating the effects of NO{sub x} emission sources on annual NO{sub 2} concentrations. Their approach, called the ambient ratio method (ARM), uses standard Gaussian dispersion models to predict NO{sub x} concentrations and the observed NO{sub 2}-to-NO{sub x} ratio to estimate the conversion of NO to NO{sub 2}. The ARM is currently the refined approach for annual NO{sub 2} modeling in the Guideline on Air Quality Models. The purpose of this paper is to present the varied experiences of several states and local air pollution agencies in applying the ARM. The South Coast Air Quality Management District in California reviewed NO{sub x} data from 22 urban monitoring stations. In general, NO{sub 2} and NO{sub x} air quality has been gradually improving over the last seven years. In addition, the NO{sub 2} to-NO{sub x} ratio has also trended downward, therefore supporting the use of the most recent data, as recommended by Chu and Meyer. The diurnal trends in both NO{sub 2} and NO{sub x} support the recommendation to calculate the ratio from the daytime averages of NO{sub 2} and NO{sub x}. All 22 sites have NO{sub 2}-to-NOx ratios less than the national default of 0.75, three sites have ratios between 0.60 and 0.69, ten sites have ratios between 0.50 and 0.59, and six sites have ratios between 0.40 and 0.49. The 20 ppb lower quantification threshold is problematic for areas with relatively low NO{sub x} concentrations, such as Alaska. The State of Alaska reviewed three years of data submitted by a private company seeking an alternative ARM value. While the data capture was around 98 percent, only four to eight percent of the data exceeded 20 ppb. This leaves insufficient data to determine the annual average NO{sub 2} and NO{sub x} concentrations needed to support an alternative ARM value.

  12. SOARCA Peach Bottom Atomic Power Station Long-Term Station Blackout Uncertainty Analysis: Convergence of the Uncertainty Results

    SciTech Connect (OSTI)

    Bixler, Nathan E.; Osborn, Douglas M.; Sallaberry, Cedric Jean-Marie; Eckert-Gallup, Aubrey Celia; Mattie, Patrick D.; Ghosh, S. Tina

    2014-02-01T23:59:59.000Z

    This paper describes the convergence of MELCOR Accident Consequence Code System, Version 2 (MACCS2) probabilistic results of offsite consequences for the uncertainty analysis of the State-of-the-Art Reactor Consequence Analyses (SOARCA) unmitigated long-term station blackout scenario at the Peach Bottom Atomic Power Station. The consequence metrics evaluated are individual latent-cancer fatality (LCF) risk and individual early fatality risk. Consequence results are presented as conditional risk (i.e., assuming the accident occurs, risk per event) to individuals of the public as a result of the accident. In order to verify convergence for this uncertainty analysis, as recommended by the Nuclear Regulatory Commission’s Advisory Committee on Reactor Safeguards, a ‘high’ source term from the original population of Monte Carlo runs has been selected to be used for: (1) a study of the distribution of consequence results stemming solely from epistemic uncertainty in the MACCS2 parameters (i.e., separating the effect from the source term uncertainty), and (2) a comparison between Simple Random Sampling (SRS) and Latin Hypercube Sampling (LHS) in order to validate the original results obtained with LHS. Three replicates (each using a different random seed) of size 1,000 each using LHS and another set of three replicates of size 1,000 using SRS are analyzed. The results show that the LCF risk results are well converged with either LHS or SRS sampling. The early fatality risk results are less well converged at radial distances beyond 2 miles, and this is expected due to the sparse data (predominance of “zero” results).

  13. Cape Canaveral Air Force Station integrated resource assessment. Volume 3, Resource assessment

    SciTech Connect (OSTI)

    Sandusky, W.F.; Eichman, C.J.; King, D.A.; McMordie, K.L.; Parker, S.A.; Shankle, S.A.; Wahlstrom, R.R.

    1994-03-01T23:59:59.000Z

    The U.S. Air Force (USAF) has tasked the Pacific Northwest Laboratory (PNL) in support of the U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP), to identify, evaluate, and assist in acquiring all cost-effective energy projects at Cape Canaveral Air Force Station (AFS). Projects considered can be either in the form of energy management or energy conservation. The overall efforts of this task are based on a model program PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at Cape Canaveral AFS, which is located approximately 10 miles north of Cocoa Beach, Florida. It is a companion report to Volume 1: Executive Summary and Volume 2: Baseline Detail. The results of the analyses of EROs are presented in 11 common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). A narrative description of each ERO is provided, including information on the installed cost, energy and dollar savings, impacts on operations and maintenance (O&M), and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. Descriptions of the evaluation methodologies and technical and cost assumptions are also provided for each ERO. Summary tables present the cost- effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost (LCC) analysis, indicating the net present value (NPV) and savings-to-investment ratio (SIR) of each ERO.

  14. EIS-0435: Modification of the Groton Generation Station Interconnection Agreement, Brown County, South Dakota

    Broader source: Energy.gov [DOE]

    This EIS evaluates the environmental impacts of a proposal for DOE's Western Area Power Administration to modify its Large Generator Connection Agreement for the Groton Generation Station in Brown County, South Dakota. The modification would allow Basin Electric Power Cooperative, which operates the generation station, to produce power above the current operating limit of 50 average megawatts.

  15. Fuel Retrieval Sub Project (FRS) Stuck Fuel Station Performance Test Data Report

    SciTech Connect (OSTI)

    THIELGES, J.R.

    2000-02-23T23:59:59.000Z

    This document provides the test data report for Stuck Fuel Station Performance Testing in support of the Fuel Retrieval Sub-Project. The stuck fuel station was designed to provide a means of cutting open a canister barrel to release fuel elements, etc.

  16. We use networks so that if one power station goes down, the area it provides

    E-Print Network [OSTI]

    Wright, Francis

    .cwh.org.uk/main.asp?page=393 ­ Battersea Power Station; www.progressillinois.com/.../images/windfarm.jpg - Wind farm; The Simpsons - nuclear power plant; http://www.projectsmonitor.com/NewsImages/ - Gas Pipeline. #12;We use networks so that if one power station goes down, the area it provides electricity

  17. innovati nNREL Furthers U.S. Marine Corps Air Station Miramar's Move Toward Net

    E-Print Network [OSTI]

    innovati nNREL Furthers U.S. Marine Corps Air Station Miramar's Move Toward Net Zero Energy The U.S. Marine Corps Air Station (MCAS) Miramar is striving toward its goal of becoming a"net zero energy"to which the net zero goal would apply. The NZEI concept focuses on the use of local clean energy resources

  18. Analysis of Cost-Effective Off-Board Hydrogen Storage and Refueling Stations

    SciTech Connect (OSTI)

    Ted Barnes; William Liss

    2008-11-14T23:59:59.000Z

    This report highlights design and component selection considerations for compressed gas hydrogen fueling stations operating at 5000 psig or 350 bar. The primary focus is on options for compression and storage – in terms of practical equipment options as well as various system configurations and how they influence delivery performance and station economics.

  19. Station blackout at nuclear power plants: Radiological implications for nuclear war

    SciTech Connect (OSTI)

    Shapiro, C.S.

    1986-12-01T23:59:59.000Z

    Recent work on station blackout is reviewed its radiological implications for a nuclear war scenario is explored. The major conclusion is that the effects of radiation from many nuclear weapon detonations in a nuclear war would swamp those from possible reactor accidents that result from station blackout.

  20. Leslie Shao-ming Sun Field Station at Jasper Ridge Biological Preserve

    E-Print Network [OSTI]

    Straight, Aaron

    , the Leslie Shao-ming Sun Field Station was designed for an annual energy budget of net zero carbon emissions emissions for its annual energy budget. The use of renewable energy sources (the sun's resources are used to the energy efficiency of the Sun Field Station: Renewable Energy · 22kW grid-connected photovoltaic system

  1. `Individual Ventilated Caging System' & `Animal Cage Changing Station' Page 1 NATIONAL INSTITUTE OF IMMUNOLOGY

    E-Print Network [OSTI]

    Bhalla, Upinder S.

    `Individual Ventilated Caging System' & `Animal Cage Changing Station' Page 1 NATIONAL INSTITUTE: (1) `Individual Ventilated Caging System' & (2) `Animal Cage Changing Station' Director, NII ­ New Document (Rs) 1 Individual Ventilated Caging System (Annexure-A) Air Handling Unit = 15 Nos. Animal

  2. Assessment of BTX Concentrations Near a Petrol Station Using Diffusive Samplers

    E-Print Network [OSTI]

    Boyer, Edmond

    Assessment of BTX Concentrations Near a Petrol Station Using Diffusive Samplers Norbert GONZALEZ to concentration levels of benzene, toluene and xylenes (BTX) at three different levels of proximity to a petrol polluted area. Keywords: Air quality, population exposure, benzene, service Station, petrol, vapour

  3. Planning and Installation Guide: North Carolina Compressed Natural Gas Fueling Stations

    E-Print Network [OSTI]

    1 Planning and Installation Guide: North Carolina Compressed Natural Gas Fueling Stations Introduction Are you considering installing a compressed natural gas (CNG) fueling station for your fleet to provide your fleet with fuel. One resource for locating and identifying public compressed natural gas

  4. Coastal Inundation due to Tide, Surge, Waves, and Sea Level Rise at Naval Station Norfolk

    E-Print Network [OSTI]

    US Army Corps of Engineers

    Coastal Inundation due to Tide, Surge, Waves, and Sea Level Rise at Naval Station Norfolk Honghai of future sea level rise (SLR) scenarios and to evaluate the potential coastal inundation at Naval Station and sea level rise threats to coastal residents and coastal military facilities, the US Strategic

  5. aspect ratio silicon: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    silicon-nitride hard-mask for high aspect-ratio silicon fins V. Jovanovi, S, Zagreb, Croatia Abstract - A method for using hard-masks to achieve sub- 100 nm patterning of...

  6. Separated Response Function Ratios in Exclusive, Forward ?[superscript ±] Electroproduction

    E-Print Network [OSTI]

    Huber, G.?M.

    The study of exclusive ?[superscript ±] electroproduction on the nucleon, including separation of the various structure functions, is of interest for a number of reasons. The ratio R[subscript L] = ?[?? over L]/?[?+ over ...

  7. Benefits and Drawbacks of Compression Ratio Reduction in PCCI...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    effect of compression ratio on performance of light duty diesel operating with PCCI calibration, near EURO6Tier 2 Bin 5 NOx limits. deer08beatrice.pdf More Documents &...

  8. Design studies of low aspect ratio quasi-omnigenous stellarators

    E-Print Network [OSTI]

    Martín-Solís, José Ramón

    optimization principles for the design of a more attractive reactor. These are 3 and 4 field period low aspect] produced low aspect ratio stellarator configurations that had promising features for a reactor (stable

  9. aspect ratio effects: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    contribute a major portion of atmospheric aerosol mass loading 5. The estimated global annual Liou, K. N. 2 Effects of aspect ratio of MWNT on the flammability properties of...

  10. Rapid Replication of High Aspect Ratio Molds for UV Embossing

    E-Print Network [OSTI]

    Yan, Yehai

    This paper describes a promising fabrication technique for rapid replication of high aspect ratio microstructured molds for UV embossing. The process involves casting silicone rubber on a microstructured master, replicating ...

  11. Water Quality Modeling, CEGR 6141 Spring 1999, Bowen

    E-Print Network [OSTI]

    Bowen, James D.

    PM, Wednesday, April 28, 1999 · no discussion of test problems allowed 1. Eutrophication Prediction a) in Kitsap County, Washington (a suburb of Seattle). The lake is experiencing eutrophication problems. Several eutrophication control measures have been proposed, as follows: 1. requiring 50 ft. "natural

  12. UNDERSTANDING THE US-CHINA TRADE Henry Bowen

    E-Print Network [OSTI]

    New Hampshire, University of

    is in the midst of economic change Economic future uncertain for Chinese households Massive incentives to save, declined from 47% of GDP to 36% in past 10 years #12;CASE STUDY 3 recent changes to China's economic

  13. Women @ Energy: Esther E. Bowen | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy China 2015ofDepartment of EnergyThe U.S.Department ofWomen @WomenElizabethErinEsther

  14. DOE - Office of Legacy Management -- Bowen Lab - NJ 33

    Office of Legacy Management (LM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilA group currentBradleyTable ofArizonaBuffalo - NYBowen Lab - NJ 33 FUSRAP

  15. Women @ Energy: Esther E. Bowen | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your DensityEnergy U.S.-China Electric VehicleCenters | Department ofoftoMayWisingJoanne

  16. System and method for high precision isotope ratio destructive analysis

    DOE Patents [OSTI]

    Bushaw, Bruce A; Anheier, Norman C; Phillips, Jon R

    2013-07-02T23:59:59.000Z

    A system and process are disclosed that provide high accuracy and high precision destructive analysis measurements for isotope ratio determination of relative isotope abundance distributions in liquids, solids, and particulate samples. The invention utilizes a collinear probe beam to interrogate a laser ablated plume. This invention provides enhanced single-shot detection sensitivity approaching the femtogram range, and isotope ratios that can be determined at approximately 1% or better precision and accuracy (relative standard deviation).

  17. TOKAMAK REACTOR DESIGNS AS A FUNCTION OF ASPECT RATIO

    E-Print Network [OSTI]

    California at Los Angeles, University of

    GA­A23168 TOKAMAK REACTOR DESIGNS AS A FUNCTION OF ASPECT RATIO by C.P.C. WONG and R.D. STAMBAUGH or reflect those of the United States Government or any agency thereof. #12;GA­A23168 TOKAMAK REACTOR DESIGNS JULY 1999 #12;C.P.C. WONG AND R.D. STAMBAUGH TOKAMAK REACTOR DESIGNS AS A FUNCTION OF ASPECT RATIO

  18. Interpretation of the atmospheric muon charge ratio in MINOS

    E-Print Network [OSTI]

    Philip Schreiner; Maury Goodman

    2007-06-04T23:59:59.000Z

    MINOS is the first large magnetic detector deep underground and is the first to measure the muon charge ratio with high statistics in the region near 1 TeV.\\cite{bib:adamson} An approximate formula for the muon charge ratio can be expressed in terms of $\\epsilon_\\pi$ = 115 GeV, $\\epsilon_K$ = 850 GeV and $\\ec$. The implications for K production in the atmosphere will be discussed.

  19. Could Gaussian regenerative stations act as quantum repeaters?

    E-Print Network [OSTI]

    Ryo Namiki; Oleg Gittsovich; Saikat Guha; Norbert Lütkenhaus

    2014-10-02T23:59:59.000Z

    Higher transmission loss diminishes the performance of optical communication|be it the rate at which classical or quantum data can be sent reliably, or the secure key generation rate of quantum key distribution (QKD). Loss compounds with distance|exponentially in an optical fiber, and inverse-square with distance for a free-space channel. In order to boost classical communication rates over long distances, it is customary to introduce regenerative relays at intermediate points along the channel. It is therefore natural to speculate whether untended regenerative stations, such as phase-insensitive or phase-sensitive optical amplifiers, could serve as repeaters for long-distance QKD. The primary result of this paper rules out all bosonic Gaussian channels to be useful as QKD repeaters, which include phase-insensitive and phase-sensitive amplifiers as special cases, for any QKD protocol. We also delineate the conditions under which a Gaussian relay renders a lossy channel entanglement breaking, which in turn makes the channel useless for QKD.

  20. Local control stations: Human engineering issues and insights

    SciTech Connect (OSTI)

    Brown, W.S.; Higgins, J.C.; O`Hara, J.M. [Brookhaven National Lab., Upton, NY (United States)

    1994-09-01T23:59:59.000Z

    The objective of this research project was to evaluate current human engineering at local control stations (LCSs) in nuclear power plants, and to identify good human engineering practices relevant to the design of these operator interfaces. General literature and reports of operating experience were reviewed to determine the extent and type of human engineering deficiencies at LCSs in nuclear power plants. In-plant assessments were made of human engineering at single-function as well as multifunction LCSs. Besides confirming the existence of human engineering deficiencies at LCSs, the in-plant assessments provided information about the human engineering upgrades that have been made at nuclear power plants. Upgrades were typically the result of any of three influences regulatory activity, broad industry initiatives such as INPO, and specific in-plant programs (e.g. activities related to training). It is concluded that the quality of LCSs is quite variable and might be improved if there were greater awareness of good practices and existing human engineering guidance relevant to these operator interfaces, which is available from a variety of sources. To make such human engineering guidance more readily accessible, guidelines were compiled from such sources and included in the report as an appendix.

  1. Rotating Target Development for SNS Second Target Station

    SciTech Connect (OSTI)

    McManamy, Thomas J [ORNL; Rennich, Mark J [ORNL; Crawford, Roy K [ORNL; Geoghegan, Patrick J [ORNL; Janney, Jim G [ORNL

    2010-01-01T23:59:59.000Z

    A rotating target for the second target station (STS) at SNS has been identified as an option along with a mercury target. Evaluation of the rotating target alternative for STS has started at 1.5 MW which is considered an upper bound for the power. Previous preconceptual design work for a 3 MW rotating target is being modified for the lower power level. Transient thermal analysis for a total loss of active water cooling has been done for a simplified 2D model of the target and shielding monolith which shows that peak temperatures are well below the level at which tungsten vaporization by steam could exceed site boundary dose limits. Design analysis and integration configuration studies have been done for the target-moderator-reflector assembly which maximizes the number of neutron beam lines and provides for replacement of the target and moderators. Target building hot cell arrangement for this option will be described. An option for operation in rough vacuum without a proton beam window using Ferro fluid seals on a vertical shaft is being developed. A full scale prototypic drive module based on the 3 MW preconceptual design has been fabricated and successfully tested with a shaft and mock up target supplied by the ESS-Bilbao team. Overall planning leading to decision between mercury and the rotating target in 2011 will be discussed

  2. Renewable Energy Optimization Report for Naval Station Newport

    SciTech Connect (OSTI)

    Robichaud, R.; Mosey, G.; Olis, D.

    2012-02-01T23:59:59.000Z

    In 2008, the U.S. Environmental Protection Agency (EPA) launched the RE-Powering America's Land initiative to encourage the development of renewable energy (RE) on potentially contaminated land and mine sites. As part of this effort, EPA is collaborating with the U.S. Department of Energy's (DOE's) National Renewable Energy Laboratory (NREL) to evaluate RE options at Naval Station (NAVSTA) Newport in Newport, Rhode Island. NREL's Renewable Energy Optimization (REO) tool was utilized to identify RE technologies that present the best opportunity for life-cycle cost-effective implementation while also serving to reduce energy-related carbon dioxide emissions and increase the percentage of RE used at NAVSTA Newport. The technologies included in REO are daylighting, wind, solar ventilation preheating (SVP), solar water heating, photovoltaics (PV), solar thermal (heating and electric), and biomass (gasification and cogeneration). The optimal mix of RE technologies depends on several factors including RE resources; technology cost and performance; state, utility, and federal incentives; and economic parameters (discount and inflation rates). Each of these factors was considered in this analysis. Technologies not included in REO that were investigated separately per NAVSTA Newport request include biofuels from algae, tidal power, and ground source heat pumps (GSHP).

  3. Angle stations in or for endless conveyor belts

    DOE Patents [OSTI]

    Steel, Alan (Glasgow, GB6)

    1987-04-07T23:59:59.000Z

    In an angle station for an endless conveyor belt, there are presented to each incoming run of the belt stationary curved guide members (18, 19) of the shape of a major segment of a right-circular cylinder and having in the part-cylindrical portion (16 or 17) thereof rectangular openings (15) arranged in parallel and helical paths and through which project small freely-rotatable rollers (14), the continuously-changing segments of the curved surfaces of which projecting through said openings (15) are in attitude to change the direction of travel of the belt (13) through 90.degree. during passage of the belt about the part-cylindrical portion (16 or 17) of the guide member (18 or 19). The rectangular openings (15) are arranged with their longer edges lengthwise of the diagonals representing the mean of the helix but with those of a plurality of the rows nearest to each end of the part-cylindrical portion (16 or 17) slightly out of axial symmetry with said diagonals, being slightly inclined in a direction about the intersections (40) of the diagonals of the main portion of the openings, to provide a "toe-in" attitude in relation to the line of run of the endless conveyor belt.

  4. Increasing the transformer ratio at the Argonne wakefield accelerator.

    SciTech Connect (OSTI)

    Power, J.G.; Conde, M.; Liu, W.; Yusof, Z.; Gai, W.; Jing, C.; Kanareykin, A. (High Energy Physics); (Euclid Techlabs, LLC)

    2011-01-01T23:59:59.000Z

    The transformer ratio is defined as the ratio of the maximum energy gain of the witness bunch to the maximum energy loss experienced by the drive bunch (or a bunch within a multidrive bunch train). This plays an important role in the collinear wakefield acceleration scheme. A high transformer ratio is desirable since it leads to a higher overall efficiency under similar conditions (e.g. the same beam loading, the same structure, etc.). One technique to enhance the transformer ratio beyond the ordinary limit of 2 is to use a ramped bunch train. The first experimental demonstration observed a transformer ratio only marginally above 2 due to the mismatch between the drive microbunch length and the frequency of the accelerating structure [C. Jing, A. Kanareykin, J. Power, M. Conde, Z. Yusof, P. Schoessow, and W. Gai, Phys. Rev. Lett. 98, 144801 (2007)]. Recently, we revisited this experiment with an optimized microbunch length using a UV laser stacking technique at the Argonne Wakefield Accelerator facility and measured a transformer ratio of 3.4. Measurements and data analysis from these experiments are presented in detail.

  5. The interaction of public/private development constraints : opportunities for the reuse of Kansas City's historic Union Station

    E-Print Network [OSTI]

    Thomas, James E

    1986-01-01T23:59:59.000Z

    Conclusions show that the previous commitments of city benefits is not likely to spur a redevelopment of Un ion Station. Because of the high level of risk of the station project, large parking requirements, and the high ...

  6. Beta-delayed Neutron Spectroscopy of $^{130-132}$Cd Isotopes with the ISOLDE Decay Station and the VANDLE array

    E-Print Network [OSTI]

    Madurga Flores, Miguel; Kolos, K; Bardayan, D; Borge, M J G; Brewer, N T; Cocolios, T E; Cizewski, J A; Dillman, I; Fijalkowska, A; Fraile, L M; Gross, C J; Goetz, K C; Ilyushkin, S V; Mazzocchi, C; Manning, B; Miernik, K; Miller, D; Paulauskas, S V; Peters, W A; Ratkiewicz, A; Rykaczewski, K P; Taylor, S; Tengblad, O; Sotty, C; De Witte, H; Xiao, Y; CERN. Geneva. ISOLDE and neutron Time-of-Flight Experiments Committee; INTC

    2014-01-01T23:59:59.000Z

    Beta-delayed Neutron Spectroscopy of $^{130-132}$Cd Isotopes with the ISOLDE Decay Station and the VANDLE array

  7. Integrated TRAC/MELPROG analyses of a PWR station blackout

    SciTech Connect (OSTI)

    Henninger, R.; Dearing, J.F.

    1987-01-01T23:59:59.000Z

    The first complete, coupled, and largely mechanistic analysis of the entire reactor-coolant system during a station blackout (TMLB') core-meltdown accident has been made with MELPROG/TRAC. The calculation was initiated at the start of the transient and ended with a late recovery of cooling. Additional cooling provided by water from the primary system delayed events relative to a standalone MELPROG calculation. Natural circulation within the vessel was established and primary-relief-valve action did little to disturb this flow. In addition, it was calculated directly that the hot leg reached a failure temperature long before vessel failure. Beyond relocation of the core, we have calculated the boiloff of the water in the lower head and have estimated the time of vessel failure to be at about 14,700 s into the transient. For ''nominal'' corium-water heat transfer, the boiloff process (steam-production rate) is slow enough that the relief valves prevent pressurization beyond 17.5 MPa. Parametric cases with increased corium-water heat transfer resulted in steaming rates beyond the capability of the relief valves, leading to pressures in excess of 19.2 MPa. Natural convection flow around the loop, if started by removing the water in the loop seal, was blocked by a relatively less-dense hydrogen/steam mixture that flowed to the top of the steam generator. Emergency core-cooling system activation late in the transient (after core slump) resulted in rapid cooling of the periphery of the debris region but slower cooling in the interior regions because of poor water penetration.

  8. Development of polymer concrete vaults for natural gas regulator stations

    SciTech Connect (OSTI)

    Fontana, J.J.; Miller, C.A.; Reams, W.; Elling, D.

    1990-08-01T23:59:59.000Z

    Vaults for natural gas regulator stations have traditionally been fabricated with steel-reinforced portland cement concrete. Since these vaults are installed below ground level, they are usually coated with a water-proofing material to prevent the ingress of moisture into the vault. In some cases, penetrations for piping that are normally cast into the vault do not line up with the gas lines in the streets. This necessitates off-setting the lines to line up with the penetrations in the vault or breaking out new penetrations which could weaken the structure and/or allow water ingress. By casting the vaults using a new material of construction such as polymer concrete, a longer maintenance free service life is possible because the physical and durability properties of polymer concrete composites are much superior to those of portland cement concrete. The higher strengths of polymer concrete allow the design engineer to reduce the wall, floor, and ceiling thicknesses making the vaults lighter for easier transportation and installation. Penetrations can be cut after casting to match existing street lines, thus making the vault more universal and reducing the number of vaults that are normally in stock. The authors developed a steel-fiber reinforced polymer concrete composite that could be used for regulator vaults. Based on the physical properties of his new composite, vaults were designed to replace the BUG PV-008 and Con Ed GR-6 regulator vaults made of reinforced portland cement concrete. Quarter-scale models of the polymer concrete vaults were tested and the results reaffirmed the reduced wall thickness design. Two sets of vaults, cast by Hardinge Bros., were inspected by representatives of the utilities and BNL (Brookhaven National Laboratory), and were accepted for delivery. 6 refs., 5 figs., 12 tabs.

  9. Enhancement of NRC station blackout requirements for nuclear power plants

    SciTech Connect (OSTI)

    McConnell, M. W. [United States Nuclear Regulatory Commission, Mail Stop: 012-H2, Washington, DC 20555 (United States)

    2012-07-01T23:59:59.000Z

    The U.S. Nuclear Regulatory Commission (NRC) established a Near-Term Task Force (NTTF) in response to Commission direction to conduct a systematic and methodical review of NRC processes and regulations to determine whether the agency should make additional improvements to its regulatory system and to make recommendations to the Commission for its policy direction, in light of the accident at the Fukushima Dai-ichi Nuclear Power Plant. The NTTF's review resulted in a set of recommendations that took a balanced approach to defense-in-depth as applied to low-likelihood, high-consequence events such as prolonged station blackout (SBO) resulting from severe natural phenomena. Part 50, Section 63, of Title 10 of the Code of Federal Regulations (CFR), 'Loss of All Alternating Current Power,' currently requires that each nuclear power plant must be able to cool the reactor core and maintain containment integrity for a specified duration of an SBO. The SBO duration and mitigation strategy for each nuclear power plant is site specific and is based on the robustness of the local transmission system and the transmission system operator's capability to restore offsite power to the nuclear power plant. With regard to SBO, the NTTF recommended that the NRC strengthen SBO mitigation capability at all operating and new reactors for design-basis and beyond-design-basis external events. The NTTF also recommended strengthening emergency preparedness for prolonged SBO and multi-unit events. These recommendations, taken together, are intended to clarify and strengthen US nuclear reactor safety regarding protection against and mitigation of the consequences of natural disasters and emergency preparedness during SBO. The focus of this paper is on the existing SBO requirements and NRC initiatives to strengthen SBO capability at all operating and new reactors to address prolonged SBO stemming from design-basis and beyond-design-basis external events. The NRC initiatives are intended to enhance core and spent fuel pool cooling, reactor coolant system integrity, and containment integrity. (authors)

  10. Evaluation of MELCOR improvements: Peach Bottom station blackout analyses

    SciTech Connect (OSTI)

    Madni, I.K.

    1993-12-31T23:59:59.000Z

    Long-term station blackout analyses in Peach Bottom were first carried out using MELCOR 1.8BC, and later with 1.8DN, as part of an overall program between the US Nuclear Regulatory Commission (NRC) and Brookhaven National Laboratory (BNL), to provide independent assessment of MELCOR as a severe accident/source term analysis tool. In addition to the reference MELCOR calculation, several sensitivity calculations were also performed to explore the impact of varying user-input modeling and timestep control parameters on the accident progression and radionuclide releases to the environment calculated by MELCOR. An area of concern that emerged from these studies was the impact of the selection of maximum allowable timestep ({Delta}t{sub max}) on the calculational behavior of MELCOR, where the results showed significant differences in timing of key events, and a lack of convergence of the solution with reduction of {Delta}t{sub max}. These findings were reported to the NRC, SNL, and the MELCOR Peer Review Committee. As a consequence, a significant effort was undertaken to eliminate or mitigate these sensitivities. The latest released version of MELCOR, Version 1.8.2, released in April 1993, contains several new or improved models, and has corrections to mitigate numerical sensitivities. This paper presents the results of updating the earlier sensitivity studies on maximum timestep, to more properly represent the abilities of the improved MELCOR version 1.8.2. Results are presenter in terms of timing of key events, thermal-hydraulic response of the system, and environmental release of radionuclides. The impact of some of the newer models, such as falling debris quench model, and ORNL`s new BH model, is also evaluated.

  11. University of Waterloo Weather Station Summary October 2013 A warm month that was the second wettest ever in the region

    E-Print Network [OSTI]

    Le Roy, Robert J.

    University of Waterloo Weather Station Summary ­ October 2013 A warm month that was the second we have seen at the UW weather station. Back in July, the 173.0 mm was the most ever seen in the 15 year history of the UW weather station, but now October comes along with 181.4 mm. The last day

  12. Electrical transient stability and underfrequency load shedding analysis for a large pump station

    SciTech Connect (OSTI)

    Shilling, S.R. [Saudi Aramco, Dhahran (Saudi Arabia)

    1995-12-31T23:59:59.000Z

    Electrical transients from faults, loss of generation, and load swings can disrupt pump station operations. Isolated stations with no utility tie and those with weak utility ties are especially at risk. Relative to this problem, the following four main issues are addressed: (1) Analyze the methods that use high-speed underfrequency load shedding to maintain system stability and preserve station operations. (2) Analyze combustion gas turbine generator and diesel generator transient responses, as they pertain to the Electrical Engineer. (3) Discuss system component modeling and the use of low voltage circuit switching devices to shed loads. (4) Compare two computer analysis program outputs for underfrequency load shedding responses.

  13. Electrical transient stability and underfrequency load shedding analysis for a large pump station

    SciTech Connect (OSTI)

    Shilling, S.R. [Saudi Aramco, Dhahran (Saudi Arabia)] [Saudi Aramco, Dhahran (Saudi Arabia)

    1997-01-01T23:59:59.000Z

    Electrical transients from faults, loss of generation, and load swings can disrupt pump station operations. Isolated stations with no utility tie, and those with weak utility ties, are especially at risk. Relative to this problem, the following four main issues are addressed: (1) analyze the methods that use high-speed underfrequency load shedding to maintain system stability and preserve station operations; (2) analyze combustion gas turbine generator and diesel generator transient responses, as they pertain to the electrical engineer; (3) discuss system component modeling and the use of low voltage circuit switching devices to shed loads; (4) compare two computer analysis program outputs for underfrequency load shedding responses.

  14. Report of the Director on the Establishment of the New State Stations.

    E-Print Network [OSTI]

    Harrington, H. H. (Henry Hill)

    1910-01-01T23:59:59.000Z

    from the people in South and Southeast Texas relative to the establish- ment of the rice station.- Propositions for the establishment of the I station were received from a number of different places, notably from 1 the people of Bay City... to those who might desire to solicit the establishment of a station in the black land belt of North or Central Texas. Propositions were re- ceived from Denton, Greenville, Mart and Temple. At a later date a meeting of the Board was held at Stamford...

  15. Evaluation of SO{sub 2} control technologies for three SCE&G power stations

    SciTech Connect (OSTI)

    Robinson, J.A. Jr. [South Carolina Electric and Gas, Co., Columbia, SC (United States); Wiggins, D.S. [Raytheon Engineers and Constructors, Philadelphia, PA (United States)

    1995-06-01T23:59:59.000Z

    South Carolina Electric and Gas, Co. (SCE&G) commissioned a detailed engineering study evaluating flue gas desulphurization (FGD) equipment for three coal fired generating stations in 1993. Raytheon Engineers and Constructors performed the study evaluating wet and dry FGD processes at three of SCE&G`s generating stations. This paper presents the results and conclusions from the study. The following areas are discussed: (1) Station Descriptions; (2) Process Design Criteria; (3) Study Goals and Methodology; (4) Results from the Economic and Kepner-Tregoe Analysis; and (5) Study Recommendations. The paper concludes with a lessons learned section discussing issues which arose during the study.

  16. Observation of Enhanced Transformer Ratio in Collinear Wakefield Acceleration

    SciTech Connect (OSTI)

    Jing, C.; Kanareykin, A. [Euclid Techlabs, LLC, Solon, OH-44139 (United States); Power, J.; Conde, M.; Yusof, Z.; Gai, W. [High Energy Physics Division, Argonne National Laboratory, Argonne, IL-60439 (United States)

    2006-11-27T23:59:59.000Z

    The transformer ratio R is a parameter that characterizes the efficiency of the energy transferred from the drive beam to the trailing witness beam passing through a wakefield accelerating structure (all metal or dielectric based) or a plasma chamber. Using a ramped bunch train (RBT) rather than a single drive bunch, the enhanced transformer ratio (ETR) technique is able to increase the transformer ratio R above the ordinary limit of 2 for a single bunch in a collinear wakefield accelerator. The RBT is a train of electron bunches separated by half integer multiples wavelength of the wakefield. The charge of the leading bunch is lowest and subsequent bunch charges are increased in such a way as to maximize R. In this article, an experimental study of this scheme is presented in which an RBT of 2 bunches with charge ratio of 1:2.5 and bunch length {sigma}z = 2 mm were used to enhance the transformer ratio. Measurement results and data analysis show good agreement with theoretical predictions. The ETR technique demonstrated here can be used in any collinear wakefield accelerator configuration, either structure- or plasma-based.

  17. Observation of enhanced transformer ratio in collinear Wakefield acceleration.

    SciTech Connect (OSTI)

    Power, J.; Conde, M.; Yusof, Z.; Gai, W.; Jing, C.; Kanareykin, A.; High Energy Physics; Euclid Techlabs, LLC

    2006-01-01T23:59:59.000Z

    The transformer ratio R is a parameter that characterizes the efficiency of the energy transferred from the drive beam to the trailing witness beam passing through a wakefield accelerating structure (all metal or dielectric based) or a plasma chamber. Using a ramped bunch train (RBT) rather than a single drive bunch, the enhanced transformer ratio (ETR) technique is able to increase the transformer ratio R above the ordinary limit of 2 for a single bunch in a collinear wakefield accelerator. The RBT is a train of electron bunches separated by half integer multiples wavelength of the wakefield. The charge of the leading bunch is lowest and subsequent bunch charges are increased in such a way as to maximize R. In this article, an experimental study of this scheme is presented in which an RBT of 2 bunches with charge ratio of 1:2.5 and bunch length {sigma}{sub z} = 2 mm were used to enhance the transformer ratio. Measurement results and data analysis show good agreement with theoretical predictions. The ETR technique demonstrated here can be used in any collinear wakefield accelerator configuration, either structure- or plasma-based.

  18. Ratio of Pion Kaon Production in Proton Carbon Interactions

    SciTech Connect (OSTI)

    Lebedev, Andrey V.; /Harvard U.

    2007-05-01T23:59:59.000Z

    The ratio of pion-kaon production by 120 GeV/c protons incident on carbon target is presented. The data was recorded with the Main Injector Particle Production experiment at Fermi National Accelerator Laboratory. Production ratios of K{sup +}/{pi}{sup +}, K{sup -}/{pi}{sup -}, K{sup -}/K{sup +}, and {pi}{sup -}/{pi}{sup +} are measured in 24 bins in longitudinal momentum from 20 to 90 GeV/c and transverse momentum up to 2 GeV/c. The measurement is compared to existing data sets, particle production Monte Carlo results from FLUKA-06, parametrization of proton-beryllium data at 400/450 GeV/c, and ratios measured by the MINOS experiment on the NuMI target.

  19. Recent Experiment on Wakefield Transformer Ratio Enhancement at AWA

    SciTech Connect (OSTI)

    Jing, C.; Kanareykin, A. [Euclid Techlabs, LLC, 5900 Harper Rd, Solon, OH 44139 (United States); High Energy Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Power, J. G.; Conde, M.; Liu, W.; Yusof, Z.; Gai, W. [High Energy Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2010-11-04T23:59:59.000Z

    One technique to enhance the transformer ratio beyond the ordinary limit of 2 in a collinear wakefield acceleration scheme is to use a ramped bunched train (RBT). The first experimental demonstration has been reported in [1]. However, due to the mismatch between the beam bunch length and frequency of the accelerating structure, the observed transformer ratio was only marginally above 2 in the earlier experiment. We recently revisited this experiment with an optimized bunch length using the laser stacking technique at Argonne Wakefield Accelerator (AWA) facility. A transformer ratio of 3.4 has been measured using two drive bunches. Attempting to use four drive bunches met with major challenges. In this article, measurement results and data analysis from these experiments are presented in detail.

  20. Transformer ratio improvement for beam based plasma accelerators

    SciTech Connect (OSTI)

    O'Shea, Brendan; Rosenzweig, James; Barber, Samuel; Fukasawa, Atsushi; Williams, Oliver; Muggli, Patric; Yakimenko, Vitaly; Kusche, Karl [University of California, Los Angeles, Department of Physics and Astronomy, Los Angeles, CA 90095 (United States); University of Southern California, Department of Electrical Engineering, Los Angeles, CA 90089 U.S.A. and Max-Planck-Institut fuer Physik, Foehringer Ring 6, 80805 Muenchen (Germany); Accelerator Test Facility, Brookhaven National Lab, Upton, NY, 11973 (United States)

    2012-12-21T23:59:59.000Z

    Increasing the transformer ratio of wakefield accelerating systems improves the viability of present novel accelerating schemes. The use of asymmetric bunches to improve the transformer ratio of beam based plasma systems has been proposed for some time[1, 2] but suffered from lack appropriate beam creation systems. Recently these impediments have been overcome [3, 4] and the ability now exists to create bunches with current profiles shaped to overcome the symmetric beam limit of R {<=} 2. We present here work towards experiments designed to measure the transformer ratio of such beams, including theoretical models and simulations using VORPAL (a 3D capable PIC code) [5]. Specifically we discuss projects to be carried out in the quasi-nonlinear regime [6] at the UCLA Neptune Laboratory and the Accelerator Test Facility at Brookhaven National Lab.

  1. Hall viscosity to entropy ratio in higher derivative theories

    E-Print Network [OSTI]

    Dibakar Roychowdhury

    2014-09-18T23:59:59.000Z

    In this paper based on the basic principles of gauge/gravity duality we compute the hall viscosity to entropy ratio in the presence of various higher derivative corrections to the dual gravitational description embedded in an asymptotically $ AdS_{4} $ space time. As the first step of our analysis, considering the back reaction we impose higher derivative corrections to the abelian gauge sector of the theory where we notice that the ratio indeed gets corrected at the leading order in the coupling. Considering the probe limit as a special case we compute this leading order correction over the fixed background of the charged black brane solution. Finally we consider higher derivative ($ R^{2} $) correction to the gravity sector of the theory where we notice that the above ratio might get corrected at the sixth derivative level.

  2. Particle acceleration in thick parallel shocks with high compression ratio

    E-Print Network [OSTI]

    Joni J. P. Virtanen; Rami Vainio

    2005-06-06T23:59:59.000Z

    We report studies on first-order Fermi acceleration in parallel modified shock waves with a large scattering center compression ratio expected from turbulence transmission models. Using a Monte Carlo technique we have modeled particle acceleration in shocks with a velocity ranging from nonrelativistic to ultrarelativistic and a thickness extending from nearly steplike to very wide structures exceeding the particle diffusion length by orders of magnitude. The nonrelativistic diffusion approximation is found to be surprisingly accurate in predicting the spectral index of a thick shock with large compression ratio even in the cases involving relativistic shock speeds.

  3. High transformer ratio drive beams for wakefield accelerator studies

    SciTech Connect (OSTI)

    England, R. J.; Ng, C.-K.; Frederico, J.; Hogan, M. J.; Litos, M.; Muggli, P.; Joshi, C.; An, W.; Andonian, G.; Mori, W.; Lu, W. [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Max Planck Institute for Physics, 80805 Munich (Germany); University of California Los Angeles, Los Angeles, CA 90095 (United States); Tsinghua University, Beijing (China)

    2012-12-21T23:59:59.000Z

    For wakefield based acceleration schemes, use of an asymmetric (or linearly ramped) drive bunch current profile has been predicted to enhance the transformer ratio and generate large accelerating wakes. We discuss plans and initial results for producing such bunches using the 20 to 23 GeV electron beam at the FACET facility at SLAC National Accelerator Laboratory and sending them through plasmas and dielectric tubes to generate transformer ratios greater than 2 (the limit for symmetric bunches). The scheme proposed utilizes the final FACET chicane compressor and transverse collimation to shape the longitudinal phase space of the beam.

  4. Prediction of heptanes-plus equilibrium ratios from empirical correlations

    E-Print Network [OSTI]

    McKenna, Martin James

    1988-01-01T23:59:59.000Z

    6590 305 247 0. 862 low 600 3225 158 149 0. 787 8055 313 212 0. 841 low sOV 2375 127 108 0. 746 TABLE 3-PHYS ICAL AND CRITICAL PROPERTIES Component methane ethane propane i-butane n-butane i-pentane n-pentane hexane (1b... using only one property ? critical temperature- to correlate equilibrium ratios. Campbell stated that for a fixed temperature and pressure, the equilibrium ratios of a mixture in v the equation apor-liquid equilibrium can be represented by log K...

  5. Estimate of the triton asymptotic D to S ratio

    SciTech Connect (OSTI)

    Frederico, T.; Adhikari, S.K.; Hussein, M.S.

    1988-01-01T23:59:59.000Z

    The role of the deuteron asymptotic D to S normalization ratio eta/sup d/ in the calculation of triton observables is emphasized both within a simple model and in an exact numerical calculation. We suggest a new correlation among eta/sup t//eta/sup d/ and E/sub t/ in dynamical three nucleon calculations, where eta/sup t/ is the triton asymptotic D to S ratio and E/sub t/ is the triton binding energy. Studying this correlation we obtained eta/sup t//eta/sup d/ = 1.68 +- 0.04. .AE

  6. Perfusion measurement with Rubidium 81 to Krypton 81m ratio

    E-Print Network [OSTI]

    Beasley, Charles Ward

    1982-01-01T23:59:59.000Z

    WRITE & II!FV ~ 26) FQRM4T(' REPLACE OR AF'PING OAT* FILET (Rr(4&)'I 'rfrA1) READ( IDEV r 22 & IANS IF ( (IANS, AND. '377) . EQ, '122) ICNTR=O WRITE& IDEV r 145) FORMAT(' USE OLD SEITINGSr &N&; 'rf !A1) RE*D(IDEVr22) IANS IOLD=O IF? IANS. AND. '377... TO EQUI LI!3RIUM AND POINTS TAKEN FROM THE OBSERVED (4) RATIO DECLINE REAL TIME RB-81/KR-81M RATIO VERSUS PHANTOM FLOW 17 19 10 SYMBOLIC FORMAT QF RECTILINEAR PHANTOM SCANS, SHOWING THE RELATIVE DISTRIBUTION OF RB-81 AND KR-81M AT DIFFERENT FLOW...

  7. Case Study - The Challenge: Saving Energy at a Sewage Lift Station...

    Broader source: Energy.gov (indexed) [DOE]

    With a total implementation cost of 16,000, the project yielded a simple payback of 5.4 years. Case Study - The Challenge: Saving Energy at a Sewage Lift Station Through Pump...

  8. Design principles for the development of space technology maturation laboratories aboard the International Space Station

    E-Print Network [OSTI]

    Saenz Otero, Alvar, 1975-

    2005-01-01T23:59:59.000Z

    This thesis formulates seven design principles for the development of laboratories which utilize the International Space Station (ISS) to demonstrate the maturation of space technologies. The principles are derived from ...

  9. After the gas station : redevelopment opportunities from rethinking America's vehicle refueling infrastructure

    E-Print Network [OSTI]

    Turco, Andrew

    2014-01-01T23:59:59.000Z

    Gas stations are found throughout the US, but their ubiquity causes them to go largely unnoticed. Because their purpose - refueling vehicles - is so uniform and so integral to the existing automotive transportation system, ...

  10. Optimal Control of Two-Station Tandem Production/Inventory System

    E-Print Network [OSTI]

    Veatch, Michael H.

    A manufacturing facility consisting of two stations in tandem operates in a maketo-stock mode: after production, items are placed in a finished goods inventory that services an exogenous demand. Demand that cannot be met ...

  11. Virginia Agricultural Experiment Station Bulletin 00-2 Using GIS as an Agricultural

    E-Print Network [OSTI]

    Beex, A. A. "Louis"

    Agricultural Experiment Station Bulletin 00-2 ______________________________________________________________________________ Using GIS as an Agricultural Land-Use Planning Tool Amber L. (Williams) Coleman John M. Galbraith Department of Crop and Soil Environmental Science College of Agriculture and Life Sciences Virginia Tech

  12. A lean safety review process for payloads on the International Space Station

    E-Print Network [OSTI]

    Luis, Javier de

    2003-01-01T23:59:59.000Z

    The International Space Station has the potential to serve as a unique test platform to enable technologies for a wide array of manned and unmanned NASA missions. In order to live up to its promise, the resources required ...

  13. A study of biological contaminants in rainwater collected from rooftops in Bryan and College Station Texas

    E-Print Network [OSTI]

    Vasudevan, Lakshmi Narasimhan

    2002-01-01T23:59:59.000Z

    This study was conducted to identify the presence of biological contaminants and the factors responsible for these contaminants in rainwater collected from rooftops of buildings in Bryan and College Station, Texas. Two main biological contaminants...

  14. Overview of Station Analysis Tools Developed in Support of H2USA

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    400,000 500,000 600,000 0 10 20 30 40 50 60 70 Compressor Motor Power kW HRS Compressors LH2 Methodology: Assumptions HRSAM estimates the cost of station equipment based on...

  15. Clean Cities Launches iPhone App for Alternative Fueling Station...

    Broader source: Energy.gov (indexed) [DOE]

    iPhone users now have access to a free app that locates fueling stations offering alternative fuels, including electricity, natural gas, biodiesel, E85, propane, and hydrogen. The...

  16. 2004-01-2584 You-Are-Here Maps for International Space Station

    E-Print Network [OSTI]

    Liu, Andrew

    aboard International Space Station (ISS) are proposed, based on results from previous 3D spatial extended to visiting Shuttle crews who sometimes had difficulty finding their way back to the orbiter; Mir

  17. Hydrogen Energy Stations: Poly-Production of Electricity, Hydrogen, and Thermal Energy

    E-Print Network [OSTI]

    Lipman, Timothy; Brooks, Cameron

    2006-01-01T23:59:59.000Z

    l l Hydrogen Energy Stations Ohio, and Florida. FurtherRenewable Energy Trust NJ: New Jersey BPU OH: Ohio Fuel Cellenergy technol- ogies include California, Connecticut, Massachusetts, Michigan, New Jersey, New York, Ohio and

  18. Preservation of the Texas Agricultural Experiment Station Bulletin in the Digital Repository

    E-Print Network [OSTI]

    McGeachin, Robert B.

    2010-04-23T23:59:59.000Z

    into the spreadsheet or gleaned electronically from exporting records as flat text files from the AGRICOLA database. The records in AGRICOLA originally came from Texas A&M University cataloging of the 1980s national project to microfilm experiment station...

  19. Webinar: Overview of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project

    Broader source: Energy.gov [DOE]

    Text version and video recording of the webinar titled "An Overview of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project," originally presented on November 18, 2014.

  20. Hydrogen Energy Stations: Poly-Production of Electricity, Hydrogen, and Thermal Energy

    E-Print Network [OSTI]

    Lipman, Timothy; Brooks, Cameron

    2006-01-01T23:59:59.000Z

    y d r o g e n Energy Stations New York State Energy Researchin an effort led by the New York State Energy Research andNYSERDA) (2005), “New York Hydrogen Energy Roadmap,” NYSERDA

  1. audio-magnetotelluric station location: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of Chicago ATLAS HEP, Enrico Fermi Institute 5640 S. Ellis Ave Chicago, IL 60637 October 15, 2007 Abstract A remote monitoring station located at the University of Chicago is...

  2. Development of a formula to determine outdoor residential water consumption in College Station, Texas

    E-Print Network [OSTI]

    Winkelblech, Audrey Kristen

    1997-01-01T23:59:59.000Z

    This thesis reports the findings of a telephone survey, public tax records, and water bills of 233 randomly selected single family detached residences, built between 1992 and 1994 in College Station, Texas. Weather information consisting of average...

  3. Between stations and habitations : the architecture of French science at the shore, 1830-1900

    E-Print Network [OSTI]

    Eigen, Edward

    2000-01-01T23:59:59.000Z

    This dissertation introduces a group of mutable institutions of research which emerged along the coast of France in the nineteenth century. The setting of these stations gave rise to a manner of occupation, both in the ...

  4. Webinar: An Overview of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project

    Broader source: Energy.gov [DOE]

    The Energy Department will present a live webinar entitled "An Overview of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project" on Tuesday, November 18, from 12:00...

  5. Near optimal design of fixture layouts in multi-station assembly processes

    E-Print Network [OSTI]

    Kim, Pansoo

    2004-11-15T23:59:59.000Z

    -station design may have high dimensions of design space, which can contain a lot of local optima. In this dissertation, I investigated two algorithms for optimal fixture layout designs. The first algorithm is an exchange algorithm, which was originally...

  6. PMEL Ocean Climate Station Program Meghan Cronin, Chris Sabine, Chris Meinig

    E-Print Network [OSTI]

    . Papa HOT MBARI Cold dry air blowing over warm Kuroshio Extension causes large sensible and latent heat for climate reference) Net Surface Heat Flux = TurbPMEL Ocean Climate Station Program Meghan Cronin, Chris Sabine, Chris Meinig NOAA Pacific Marine

  7. Overview of Station Analysis Tools Developed in Support of H2USA

    Broader source: Energy.gov [DOE]

    Access the recording and download presentation slides from the Fuel Cell Technologies Office webinar "Overview of Station Analysis Tools Developed in Support of H2USA" held on May 12, 2015.

  8. Retrofit of Tehran City Gate Station C.G.S. No. 2 by Using Turboexpander

    E-Print Network [OSTI]

    Seresht, R. T.; Ja, H. K.

    2010-01-01T23:59:59.000Z

    gas pressure reducing stations in Iran (both from capacity and inlet pressure perspectives), has been selected as a case study. In first step waste of energy was calculated by using exergy analysis and in second step, by using expansion turbines...

  9. Environmental design guidelines for a second generation, LEO, permanently manned space station

    E-Print Network [OSTI]

    Johnson, David Michael, 1960-

    1987-01-01T23:59:59.000Z

    This thesis is a continuation of the thoughts and efforts of the author's participation and co-organization of the Space Station Design Workshop (SSDW). The SSDW was a student run event whose inception surfaced in the ...

  10. Fort Calhoun Station disposal of spent fuel pool racks

    SciTech Connect (OSTI)

    Jamieson, T.W. [Omaha Public Power District, Fort Calhoun Station, NE (United States)

    1995-09-01T23:59:59.000Z

    The original plan was to have the racks pulled out of the pool, washed down and wrapped and placed in Sea/Lands to be sent to a vendor for free release and disposal. In the winter of 93 the proposed quotations on the Spent Fuel Rerack Processing were all rejected. With the rerack job starting in March of 94 and the closing of Barnwell in July we were faced with what to do with the racks. Processing of the existing racks were required since if the racks were sent to Barnwell for burial intact the cost would be prohibitive, that is, if Barnwell would have stayed open. If the racks were sent to a smelter, such as Scientific Ecology Group (SEG), there are restrictions on the length of the components that can go through the smelter. If SEG were to do the rack processing (sectioning) at their facility, the cost would also be prohibitive and they would not be in a position to receive the racks until June, 1995. Therefore, bid specifications were requested for on-site volume reduction processing of the existing spent fuel storage racks, with further ultimate disposal to be performed by SEG. The processing of the racks included piping and supports. Volume reduction (VR) was an issue in the evaluation since after this process the racks were to be shipped to SEG. If a low VR ratio option was chosen, OPPD would need a significant number of shipping containers and required more radwaste shipments versus if a high VR ratio option were chosen.

  11. A formative evaluation of the College Station Independent School District's guidance and counseling program

    E-Print Network [OSTI]

    Conner, Paul William

    1981-01-01T23:59:59.000Z

    for the degree of MASTER OF SCIENCE December 1981 Major Subject: Psychology A FORMATIVE EVALUATION OF THE COLLEGE STATION INDEPENDENT SCHOOL DISTRICT'S GUIDANCE AND COUNSELING PROGRAM A Thesis by PAUL lrl I LL 1 AM CONNER Approved as to sty1e... and content by: (Ch an of Committee) c(. '. c rc (Member) (Member) (Head of Department) December 1981 ABSTRACT A Formative Evaluation of the College Station Independent School District's Gu1dance and Counse11ng Program (December 1981) Paul William...

  12. Fuel Retrieval Sub (FRS) Project Decapping Station Performance Test Data Report

    SciTech Connect (OSTI)

    THIELGES, J.R.

    2000-01-13T23:59:59.000Z

    This document is to provide the test data report for Decapping Station Performance Testing. These performance tests were full scale and viewed as a continuation of development testing performed earlier (SNF-2710). A prototype decapping station confinement box was tested, along with some special tools required for the process, providing assurance that the fuel handling equipment will operate as designed, allowing for release of the FRS equipment for installation.

  13. Grazing Studies on the Amarillo Conservation Experiment Station 1943-49.

    E-Print Network [OSTI]

    Baker, John P.; Jones, John H.; Whitfield, Charles J. (Charles James)

    1949-01-01T23:59:59.000Z

    GRAZING STUDIES ON THE AMAR!LLO CONSERVATION EXPERIMENT STATION 1943-49 * in cooperation with the UNITED STATES DEPARTMENT OF AGRICULTURE THE COVER PICTURE Cholice grade ye'arling steers are shown on summer pasturage at the Amarillo Conser...- vation Experiment Station. Fall-purchased steer calves which are well wintered, become grass fat by September, provided the past~rage is grazed according to conservation practices. This has been true even in dry years. These studies on the Amarillo...

  14. Design, Modeling and Testing of the Askaryan Radio Array South Pole Autonomous Renewable Power Stations

    E-Print Network [OSTI]

    Besson, D Z; Ratzlaff, K; Young, R

    2014-01-01T23:59:59.000Z

    We describe the design, construction and operation of the Askaryan Radio Array (ARA) Autonomous Renewable Power Stations, initially installed at the South Pole in December, 2010 with the goal of providing an independently operating 100 W power source capable of year-round operation in extreme environments. In addition to particle astrophysics applications at the South Pole, such a station can easily be, and has since been, extended to operation elsewhere, as described herein.

  15. A study of College Station visitor opinions regarding hotel occupancy tax expenditures

    E-Print Network [OSTI]

    Zweifel, Eva Louise

    1976-01-01T23:59:59.000Z

    A STUDY OF COLLEGE STATION VISITOR OPINIONS REGARDING HOTEL OCCUPANCY TAX EXPENDITURES A Thesis by EVA LOUISE ZWEIFEL Submitted to the Graduate College of Texas A&M University in partial fulfillment of the requirement for the degree... of MASTER OF SCIENCE December 1976 Major Subject: Recreation and Resources Development A STUDY OF COLLEGE STATION VISITOR OPINIONS REGARDING HOTEL OCCUPANCY TAX EXPENDITURES A Thesis by EVA LOUISE ZWEIFEL Approved as to style and content by...

  16. Variation in property tax assessment in Bryan and College Station, Texas

    E-Print Network [OSTI]

    Wilson, David Snorf

    1981-01-01T23:59:59.000Z

    VARIATION IN PROPERTY TAX ASSESSMENT IN BRYAN AND COLLEGE STATION, TEXAS A Thesis by DAVID SNORF WILSON Submitted to the Graduate College of Texas A6M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE... August 1981 Major Subject: Geography VARIATION IN PROPERTY TAX ASSESSMENT IN BRYAN AND COLLEGE STATION, TEXAS A Thesis by DAVID SNORF WILSON Approved as to style and content by: (Chairman of Committee) (Member ) (Member) (Head of Department...

  17. aerosol ratio test: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    aerosol ratio test First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Effect of mineral dust aerosol...

  18. Generalized solar load ratio correlation for direct gain buildings

    SciTech Connect (OSTI)

    Wray, W.O.; Best, E.D.

    1986-01-01T23:59:59.000Z

    A generalized solar load ratio correlation has been developed for direct gain buildings by generating relationships between the correlation parameters and two fundamental design parameters. The first design parameter is the steady state conductance of the solar aperture, U/sub c/. The second is the effective heat capacity of the solar zone, EHC.

  19. Improved Signal-to-Noise Ratio Estimation for Speech Enhancement

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    1 Improved Signal-to-Noise Ratio Estimation for Speech Enhancement Cyril Plapous, Member, IEEE speech enhancement in noisy environments. State-of- the-art short-time noise reduction techniques reduction techniques, includ- ing TSNR, introduce harmonic distortion in enhanced speech because

  20. NOTE / NOTE Sex ratio variation in gynodioecious species of

    E-Print Network [OSTI]

    Dorken, Marcel

    NOTE / NOTE Sex ratio variation in gynodioecious species of Echium endemic to the Canary Islands Marcel E. Dorken Abstract: Species of Echium from the Canary Islands represent an adaptive radiation fertility of females and hermaphrodites were de- tected. Key words: Canary Islands, Echium, island radiation

  1. The Next Generation Isotope Ratio MS DELTA V Advantage

    E-Print Network [OSTI]

    Lachniet, Matthew S.

    on front panel - All pumps inside - Low noise design #12;T The Next Generation Isotope Ratio MS More than with intrinsic alignment of all ion optical components - Integrated signal amplifiers and digitizers - All ion - Comprehensive set of automated diagnostics · Compact and user-friendly design - Small footprint - Space for on

  2. Oxygen isotopic ratios in intermediate-mass red giants

    E-Print Network [OSTI]

    Lebzelter, Thomas; Hinkle, Kenneth; Nowotny, Walter; Aringer, Bernhard

    2015-01-01T23:59:59.000Z

    Context. The abundances of the three main isotopes of oxygen are altered in the course of the CNO-cycle. When the first dredge-up mixes the burning products to the surface, the nucleosynthesis processes can be probed by measuring oxygen isotopic ratios. Aims. By measuring 16O/17O and 16O/18O in red giants of known mass we compare the isotope ratios with predictions from stellar and galactic evolution modelling. Methods. Oxygen isotopic ratios were derived from the K-band spectra of six red giants. The sample red giants are open cluster members with known masses of between 1.8 and 4.5 Msun . The abundance determination employs synthetic spectra calculated with the COMARCS code. The effect of uncertainties in the nuclear reaction rates, the mixing length, and of a change in the initial abundance of the oxygen isotopes was determined by a set of nucleosynthesis and mixing models using the FUNS code. Results. The observed 16O/17O ratios are in good agreement with the model results, even if the measured values do ...

  3. RpA ratio: total shadowing due to running coupling

    E-Print Network [OSTI]

    E. Iancu; D. N. Triantafyllopoulos

    2007-07-02T23:59:59.000Z

    We predict that the RpA ratio at the most forward rapidities to be measured at LHC should be strongly suppressed, close to "total shadowing'' (RpA = A^(-1/3)), as a consequence of running coupling effects in the nonlinear QCD evolution.

  4. Prediction-Based Compression Ratio Boundaries for Medical Images

    E-Print Network [OSTI]

    Qi, Xiaojun

    Prediction-Based Compression Ratio Boundaries for Medical Images Xiaojun Qi Computer Science present prediction-based image compression techniques take advantage of either intra- or inter function. The prediction-based compression technique has been applied on some magnetic resonance (MR) brain

  5. Allowable pillar to diameter ratio for strategic petroleum reserve caverns.

    SciTech Connect (OSTI)

    Ehgartner, Brian L.; Park, Byoung Yoon

    2011-05-01T23:59:59.000Z

    This report compiles 3-D finite element analyses performed to evaluate the stability of Strategic Petroleum Reserve (SPR) caverns over multiple leach cycles. When oil is withdrawn from a cavern in salt using freshwater, the cavern enlarges. As a result, the pillar separating caverns in the SPR fields is reduced over time due to usage of the reserve. The enlarged cavern diameters and smaller pillars reduce underground stability. Advances in geomechanics modeling enable the allowable pillar to diameter ratio (P/D) to be defined. Prior to such modeling capabilities, the allowable P/D was established as 1.78 based on some very limited experience in other cavern fields. While appropriate for 1980, the ratio conservatively limits the allowable number of oil drawdowns and hence limits the overall utility and life of the SPR cavern field. Analyses from all four cavern fields are evaluated along with operating experience gained over the past 30 years to define a new P/D for the reserve. A new ratio of 1.0 is recommended. This ratio is applicable only to existing SPR caverns.

  6. Negative Poisson's Ratio Behavior Induced by an Elastic Instability

    E-Print Network [OSTI]

    Reis, Pedro Miguel

    's ratio, which is approximately 0.5 for rubber and 0.3 for glass and steel. Materials with a negative] prostheses,[3] piezocomposites with optimal performance[4] and foams with superior damping and acoustic foams with reentrant struc- tures,[1] hierarchical laminates,[12] polymeric and metallic foams,[13

  7. Analysis of the Use of Wind Energy to Supplement the Power Needs at McMurdo Station and Amundsen-Scott South Pole Station, Antarctica

    SciTech Connect (OSTI)

    Baring-Gould, I.; Robichaud, R.; McLain, K.

    2005-05-01T23:59:59.000Z

    This report summarizes an analysis of the inclusion of wind-driven power generation technology into the existing diesel power plants at two U.S. Antarctic research stations, McMurdo and Amundsen-Scott South Pole Station. Staff at the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) conducted the analysis. Raytheon Polar Services, which currently holds the private sector support contract for the two research stations, was a major contributor to this report. To conduct the analysis, available data were obtained on the wind resources, power plant conditions, load, and component cost. Whenever possible, we validated the information. We then used NREL's Hybrid2 power system modeling software to analyze the potential and cost of using wind turbine generators at the two aforementioned facilities. Unfortunately, the power systems and energy allocations at McMurdo and South Pole Station are being redeveloped, so it is not possible to validate future fuel use. This report is an initial assessment of the potential use of wind energy and should be followed by further, more detailed analysis if this option is to be considered further.

  8. The Proton Form Factor Ratio Measurements at Jefferson Lab

    SciTech Connect (OSTI)

    Punjabi, Vina A. [Norfolk State University, Norfolk, VA (United States); Perdrisat, Charles F. [William and Mary College, Williamsburg, VA (United States)

    2014-03-01T23:59:59.000Z

    The ratio of the proton form factors, G{sub Ep}/G{sub Mp}, has been measured from Q{sup 2} of 0.5 GeV{sup 2} to 8.5 GeV{sup 2}, at the Jefferson Laboratory, using the polarization transfer method. This ratio is extracted directly from the measured ratio of the transverse and longitudinal polarization components of the recoiling proton in elastic electron-proton scattering. The discovery that the proton form factor ratio measured in these experiments decreases approximately linearly with four-momentum transfer, Q{sup 2}, for values above #25;~1 GeV{sup 2}, is one of the most significant results to come out of JLab. These results have had a large impact on progress in hadronic physics; and have required a significant rethinking of nucleon structure. The increasingly common use of the double-polarization technique to measure the nucleon form factors, in the last 15 years, has resulted in a dramatic improvement of the quality of all four nucleon electromagnetic form factors, G{sub Ep}, G{sub Mp}, G{sub En} and G{sub Mn}. There is an approved experiment at JLab, GEP(V), to continue the ratio measurements to 12 GeV{sup 2}. A dedicated experimental setup, the Super Bigbite Spectrometer (SBS), will be built for this purpose. It will be equipped with a focal plane polarimeter to measure the polarization of the recoil protons. The scattered electrons will be detected in an electromagnetic calorimeter. In this presentation, I will review the status of the proton elastic electromagnetic form factors and discuss a number of theoretical approaches to describe nucleon form factors.

  9. MAGNESIUM ISOTOPE RATIOS IN {omega} CENTAURI RED GIANTS

    SciTech Connect (OSTI)

    Da Costa, G. S.; Norris, John E.; Yong, David [Research School of Astronomy and Astrophysics, Australian National University, Canberra, ACT 0200 (Australia)

    2013-05-20T23:59:59.000Z

    We have used the high-resolution observations obtained at the Anglo-Australian Telescope with Ultra-High Resolution Facility (R {approx} 100,000) and at Gemini-S with b-HROS (R {approx} 150,000) to determine magnesium isotope ratios for seven {omega} Cen red giants that cover a range in iron abundance from [Fe/H] = -1.78 to -0.78 dex, and for two red giants in M4 (NGC 6121). The {omega} Cen stars sample both the ''primordial'' (i.e., O-rich, Na- and Al-poor) and the ''extreme'' (O-depleted, Na- and Al-rich) populations in the cluster. The primordial population stars in both {omega} Cen and M4 show ({sup 25}Mg, {sup 26}Mg)/{sup 24}Mg isotopic ratios that are consistent with those found for the primordial population in other globular clusters with similar [Fe/H] values. The isotopic ratios for the {omega} Cen extreme stars are also consistent with those for extreme population stars in other clusters. The results for the extreme population stars studied indicate that the {sup 26}Mg/{sup 24}Mg ratio is highest at intermediate metallicities ([Fe/H] < -1.4 dex), and for the highest [Al/Fe] values. Further, the relative abundance of {sup 26}Mg in the extreme population stars is notably higher than that of {sup 25}Mg, in contrast to model predictions. The {sup 25}Mg/{sup 24}Mg isotopic ratio in fact does not show any obvious dependence on either [Fe/H] or [Al/Fe] nor, intriguingly, any obvious difference between the primordial and extreme population stars.

  10. OXYGEN ISOTOPIC RATIOS IN COOL R CORONAE BOREALIS STARS

    SciTech Connect (OSTI)

    Garcia-Hernandez, D. A. [Instituto de Astrofisica de Canarias (IAC), C/Via Lactea s/n, 38200 La Laguna, Tenerife (Spain); Lambert, David L. [W. J. McDonald Observatory, University of Texas at Austin. 1 University Station, C1400. Austin, TX 78712-0259 (United States); Rao, N. Kameswara [Indian Institute of Astrophysics, Bangalore 560 034 (India); Hinkle, Ken H. [National Optical Astronomy Observatory (NOAO), Tucson, AZ 85726 (United States); Eriksson, Kjell, E-mail: agarcia@iac.e, E-mail: dll@astro.as.utexas.ed, E-mail: nkrao@iiap.res.i, E-mail: hinkle@noao.ed, E-mail: Kjell.Eriksson@astro.uu.s [Department of Physics and Astronomy, Uppsala University, Box 515, 75120 Uppsala (Sweden)

    2010-05-01T23:59:59.000Z

    We investigate the relationship between R Coronae Borealis (RCB) stars and hydrogen-deficient carbon (HdC) stars by measuring precise {sup 16}O/{sup 18}O ratios for five cool RCB stars. The {sup 16}O/{sup 18}O ratios are derived by spectrum synthesis from high-resolution (R {approx} 50, 000) K-band spectra. Lower limits to the {sup 16}O/{sup 17}O and {sup 14}N/{sup 15}N ratios as well as Na and S abundances (when possible) are also given. RCB stars in our sample generally display less {sup 18}O than HdC stars-the derived {sup 16}O/{sup 18}O ratios range from 3 to 20. The only exception is the RCB star WX CrA, which seems to be an HdC-like star with {sup 16}O/{sup 18}O = 0.3. Our result of a higher {sup 16}O/{sup 18}O ratio for the RCB stars must be accounted for by a theory of the formation and evolution of HdC and RCB stars. We speculate that a late dredge-up of products of He burning, principally {sup 12}C and {sup 16}O, may convert an {sup 18}O-rich HdC star into an {sup 18}O-poor RCB star as the H-deficient star begins its final evolution from a cool supergiant to the top of the white dwarf cooling track.

  11. Introduction and Case Studies The Ratio Plot Under Homogeneity and the Decontaminated Turing

    E-Print Network [OSTI]

    Boehning, Dankmar

    Outline Introduction and Case Studies The Ratio Plot Under Homogeneity and the Decontaminated Introduction and Case Studies The Ratio Plot Under Homogeneity and the Decontaminated Turing The Ratio Plot The Ratio Plot Under Homogeneity and the Decontaminated Turing The Ratio Plot and Structured Heterogeneity

  12. Baghouse Slipstream Testing at TXU's Big Brown Station

    SciTech Connect (OSTI)

    John Pavlish; Jason Laumb; Robert Jensen; Jeffery Thompson; Christopher Martin; Mark Musich; Brandon Pavlish; Stanley Miller; Lucinda Hamre

    2007-04-30T23:59:59.000Z

    Performing sorbent testing for mercury control at a large scale is a very expensive endeavor and requires months of planning and careful execution. Even with good planning, there are plant limitations on what operating/design parameters can be varied/tested and when. For parameters that cannot be feasibly tested at the full scale (lower/higher gas flow, different bag material, cleaning methods, sorbents, etc.), an alternative approach is used to perform tests on a slipstream unit using flue gas from the plant. The advantage that a slipstream unit provides is the flexibility to test multiple operating and design parameters and other possible technology options without risking major disruption to the operation of the power plant. Additionally, the results generated are expected to simulate full-scale conditions closely, since the flue gas used during the tests comes directly from the plant in question. The Energy & Environmental Research Center developed and constructed a mobile baghouse that allows for cost-effective testing of impacts related to variation in operating and design parameters, as well as other possible mercury control options. Multiple sorbents, air-to-cloth ratios, bag materials, and cleaning frequencies were evaluated while flue gas was extracted from Big Brown when it fired a 70% Texas lignite-30% Powder River Basin (PRB) blend and a 100% PRB coal.

  13. Corrective action decision document, Second Gas Station, Tonopah test range, Nevada (Corrective Action Unit No. 403)

    SciTech Connect (OSTI)

    NONE

    1997-11-01T23:59:59.000Z

    This Corrective Action Decision Document (CADD) for Second Gas Station (Corrective Action Unit [CAU] No. 403) has been developed for the U.S. Department of Energy`s (DOE) Nevada Environmental Restoration Project to meet the requirements of the Federal Facility Agreement and Consent Order (FFACO) of 1996 as stated in Appendix VI, {open_quotes}Corrective Action Strategy{close_quotes} (FFACO, 1996). The Second Gas Station Corrective Action Site (CAS) No. 03-02-004-0360 is the only CAS in CAU No. 403. The Second Gas Station CAS is located within Area 3 of the Tonopah Test Range (TTR), west of the Main Road at the location of former Underground Storage Tanks (USTs) and their associated fuel dispensary stations. The TTR is approximately 225 kilometers (km) (140 miles [mi]) northwest of Las Vegas, Nevada, by air and approximately 56 km (35 mi) southeast of Tonopah, Nevada, by road. The TTR is bordered on the south, east, and west by the Nellis Air Force Range and on the north by sparsely populated public land administered by the Bureau of Land Management and the U.S. Forest Service. The Second Gas Station CAS was formerly known as the Underground Diesel Tank Site, Sandia Environmental Restoration Site Number 118. The gas station was in use from approximately 1965 to 1980. The USTs were originally thought to be located 11 meters (m) (36 feet [ft]) east of the Old Light Duty Shop, Building 0360, and consisted of one gasoline UST (southern tank) and one diesel UST (northern tank) (DOE/NV, 1996a). The two associated fuel dispensary stations were located northeast (diesel) and southeast (gasoline) of Building 0360 (CAU 423). Presently the site is used as a parking lot, Building 0360 is used for mechanical repairs of vehicles.

  14. Beta-decay branching ratios of 62Ga

    E-Print Network [OSTI]

    A. Bey; B. Blank; G. Canchel; C. Dossat; J. Giovinazzo; I. Matea; V. Elomaa; T. Eronen; U. Hager; M. Hakala; A. Jokinen; A. Kankainen; I. Moore; H. Penttila; S. Rinta-Antila; A. Saastamoinen; T. Sonoda; J. Aysto; N. Adimi; G. De France; J. C. Thomas; G. Voltolini; T. Chaventré

    2008-04-17T23:59:59.000Z

    Beta-decay branching ratios of 62Ga have been measured at the IGISOL facility of the Accelerator Laboratory of the University of Jyvaskyla. 62Ga is one of the heavier Tz = 0, 0+ -> 0+ beta-emitting nuclides used to determine the vector coupling constant of the weak interaction and the Vud quark-mixing matrix element. For part of the experimental studies presented here, the JYFLTRAP facility has been employed to prepare isotopically pure beams of 62Ga. The branching ratio obtained, BR= 99.893(24)%, for the super-allowed branch is in agreement with previous measurements and allows to determine the ft value and the universal Ft value for the super-allowed beta decay of 62Ga.

  15. Ratios of Helicity Amplitudes for Exclusive rho-0 Electroproduction

    E-Print Network [OSTI]

    Airapetian, A; Akopov, Z; Aschenauer, E C; Augustyniak, W; Avakian, R; Avetissian, A; Avetisyan, E; Belostotski, S; Bianchi, N; Blok, H P; Borissov, A; Bowles, J; Bryzgalov, V; Burns, J; Capiluppi, M; Capitani, G P; Cisbani, E; Ciullo, G; Contalbrigo, M; Dalpiaz, P F; Deconinck, W; De Leo, R; De Nardo, L; De Sanctis, E; Diefenthaler, M; Di Nezza, P; Dueren, M; Ehrenfried, M; Elbakian, G; Ellinghaus, F; Fabbri, R; Fantoni, A; Felawka, L; Frullani, S; Gabbert, D; Gapienko, G; Gapienko, V; Garibaldi, F; Gavrilov, G; Gharibyan, V; Giordano, F; Gliske, S; Golembiovskaya, M; Hadjidakis, C; Hartig, M; Hasch, D; Hill, G; Hillenbrand, A; Hoek, M; Holler, Y; Hristova, I; Imazu, Y; Ivanilov, A; Jackson, H E; Jo, H S; Joosten, S; Kaiser, R; Karyan, G; Keri, T; Kinney, E; Kisselev, A; Kobayashi, N; Korotkov, V; Kozlov, V; Kravchenko, P; Krivokhijine, V G; Lagamba, L; Lamb, R; Lapikas, L; Lehmann, I; Lenisa, P; Linden-Levy, L A; Ruiz, A Lopez; Lorenzon, W; Lu, X -G; Lu, X -R; Ma, B -Q; Mahon, D; Makins, N C R; Manaenkov, S I; Manfre, L; Mao, Y; Marianski, B; de la Ossa, A Martinez; Marukyan, H; Miller, C A; Miyachi, Y; Movsisyan, A; Muccifora, V; Murray, M; Mussgiller, A; Nappi, E; Naryshkin, Y; Nass, A; Negodaev, M; Nowak, W -D; Pappalardo, L L; Perez-Benito, R; Pickert, N; Reimer, P E; Reolon, A R; Riedl, C; Rith, K; Rosner, G; Rostomyan, A; Rubin, J; Ryckbosch, D; Salomatin, Y; Sanftl, F; Schaefer, A; Schnell, G; Schueler, K P; Seitz, B; Shibata, T -A; Shutov, V; Stancari, M; Statera, M; Steffens, E; Steijger, J J M; Stinzing, F; Taroian, S; Terkulov, A; Trzcinski, A; Tytgat, M; Vandenbroucke, A; Van Haarlem, Y; Van Hulse, C; Veretennikov, D; Vikhrov, V; Vilardi, I; Wang, S; Yaschenko, S; Yen, S; Yu, W; Zihlmann, B; Zupranski, P

    2010-01-01T23:59:59.000Z

    Exclusive rho^0-meson electroproduction is studied in the HERMES experiment, using a 27.6 GeV longitudinally polarized electron/positron beam and unpolarized hydrogen and deuterium targets in the kinematic region 0.5 GeV^2 \\rho_T), T_{01} (\\gamma^*_T --> \\rho_L), T_{10} (\\gamma^*_L --> \\rho_T), and T_{1-1} (\\gamma^*_{-T} -->\\rho_T) to T_{00} (\\gamma^*_L --> \\rho_L) are extracted from the data. For the unnatural-parity-exchange amplitude U_{11}, the ratio |U_{11}/T_{00}| is obtained. The Q^2 and t' dependences of these ratios are presented and compared with perturbative QCD predictions.

  16. Ratios of Helicity Amplitudes for Exclusive rho-0 Electroproduction

    E-Print Network [OSTI]

    The HERMES Collaboration; A. Airapetian; N. Akopov; Z. Akopov; E. C. Aschenauer; W. Augustyniak; R. Avakian; A. Avetissian; E. Avetisyan; S. Belostotski; N. Bianchi; H. P. Blok; A. Borissov; J. Bowles; V. Bryzgalov; J. Burns; M. Capiluppi; G. P. Capitani; E. Cisbani; G. Ciullo; M. Contalbrigo; P. F. Dalpiaz; W. Deconinck; R. De Leo; L. De Nardo; E. De Sanctis; M. Diefenthaler; P. Di Nezza; M. Dueren; M. Ehrenfried; G. Elbakian; F. Ellinghaus; R. Fabbri; A. Fantoni; L. Felawka; S. Frullani; D. Gabbert; G. Gapienko; V. Gapienko; F. Garibaldi; G. Gavrilov; V. Gharibyan; F. Giordano; S. Gliske; M. Golembiovskaya; C. Hadjidakis; M. Hartig; D. Hasch; G. Hill; A. Hillenbrand; M. Hoek; Y. Holler; I. Hristova; Y. Imazu; A. Ivanilov; H. E. Jackson; H. S. Jo; S. Joosten; R. Kaiser; G. Karyan; T. Keri; E. Kinney; A. Kisselev; N. Kobayashi; V. Korotkov; V. Kozlov; P. Kravchenko; V. G. Krivokhijine; L. Lagamba; R. Lamb; L. Lapikas; I. Lehmann; P. Lenisa; L. A. Linden-Levy; A. Lopez Ruiz; W. Lorenzon; X. -G. Lu; X. -R. Lu; B. -Q. Ma; D. Mahon; N. C. R. Makins; S. I. Manaenkov; L. Manfre; Y. Mao; B. Marianski; A. Martinez de la Ossa; H. Marukyan; C. A. Miller; Y. Miyachi; A. Movsisyan; V. Muccifora; M. Murray; A. Mussgiller; E. Nappi; Y. Naryshkin; A. Nass; M. Negodaev; W. -D. Nowak; L. L. Pappalardo; R. Perez-Benito; N. Pickert; P. E. Reimer; A. R. Reolon; C. Riedl; K. Rith; G. Rosner; A. Rostomyan; J. Rubin; D. Ryckbosch; Y. Salomatin; F. Sanftl; A. Schaefer; G. Schnell; K. P. Schueler; B. Seitz; T. -A. Shibata; V. Shutov; M. Stancari; M. Statera; E. Steffens; J. J. M. Steijger; F. Stinzing; S. Taroian; A. Terkulov; A. Trzcinski; M. Tytgat; A. Vandenbroucke; Y. Van Haarlem; C. Van Hulse; D. Veretennikov; V. Vikhrov; I. Vilardi; S. Wang; S. Yaschenko; S. Yen; W. Yu; B. Zihlmann; P. Zupranski

    2011-05-02T23:59:59.000Z

    Exclusive rho^0-meson electroproduction is studied in the HERMES experiment, using a 27.6 GeV longitudinally polarized electron/positron beam and unpolarized hydrogen and deuterium targets in the kinematic region 0.5 GeV^2 \\rho_T), T_{01} (\\gamma^*_T --> \\rho_L), T_{10} (\\gamma^*_L --> \\rho_T), and T_{1-1} (\\gamma^*_{-T} -->\\rho_T) to T_{00} (\\gamma^*_L --> \\rho_L) are extracted from the data. For the unnatural-parity-exchange amplitude U_{11}, the ratio |U_{11}/T_{00}| is obtained. The Q^2 and t' dependences of these ratios are presented and compared with perturbative QCD predictions.

  17. Backward running or absence of running from Creutz ratios

    SciTech Connect (OSTI)

    Giedt, Joel; Weinberg, Evan [Department of Physics, Applied Physics and Astronomy, Rensselaer Polytechnic Institute, 110 8th Street, Troy, New York 12065 (United States)

    2011-10-01T23:59:59.000Z

    We extract the running coupling based on Creutz ratios in SU(2) lattice gauge theory with two Dirac fermions in the adjoint representation. Depending on how the extrapolation to zero fermion mass is performed, either backward running or an absence of running is observed at strong bare coupling. This behavior is consistent with other findings which indicate that this theory has an infrared fixed point.

  18. Radar antenna pointing for optimized signal to noise ratio.

    SciTech Connect (OSTI)

    Doerry, Armin Walter; Marquette, Brandeis [General Atomics Aeronautical Systems, Inc., San Diego, CA

    2013-01-01T23:59:59.000Z

    The Signal-to-Noise Ratio (SNR) of a radar echo signal will vary across a range swath, due to spherical wavefront spreading, atmospheric attenuation, and antenna beam illumination. The antenna beam illumination will depend on antenna pointing. Calculations of geometry are complicated by the curved earth, and atmospheric refraction. This report investigates optimizing antenna pointing to maximize the minimum SNR across the range swath.

  19. Dilepton to photon ratio, a viscometer of QGP

    E-Print Network [OSTI]

    Chaudhuri, A K

    2012-01-01T23:59:59.000Z

    In the Israel-Stewart's 2nd order hydrodynamics, a viscous effect on dilepton emission from a QGP medium is investigated. Dileptons are strongly affected by QGP viscosity. Large invariant mass dileptons, due to their lower velocity, are less affected by viscosity than the low invariant mass dileptons. We also show that the ratio of photon to dilepton is sensitive to the viscosity and can serve as a viscometer for QGP.

  20. The use of carbon stable isotope ratios in drugs characterization

    SciTech Connect (OSTI)

    Magdas, D. A., E-mail: gabriela.cristea@itim-cj.ro; Cristea, G., E-mail: gabriela.cristea@itim-cj.ro; Bot, A., E-mail: gabriela.cristea@itim-cj.ro; Mirel, V., E-mail: gabriela.cristea@itim-cj.ro [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath Str., 400293 Cluj-Napoca (Romania)

    2013-11-13T23:59:59.000Z

    Isotopic Ratio Mass Spectrometry (IRMS) is an effective toll to be used for drug product authentication. The isotopic composition could be used to assist in the differentiation between batches of drugs and assist in the identification of counterfeit materials on the market. Only two factors affect the isotopic ratios in pharmaceutical components: the isotopic composition of the raw materials and the synthetic processes performed upon them. Counterfeiting of pharmaceutical drugs threatens consumer confidence in drug products companies' economical well-being. In this preliminary study, the analyzed samples consist in two types of commercially available analgesics, which were purchases from Romanian pharmacies. Differences in ?{sup 13}C between batches from ?29.7 to ?31.6% were observed, demonstrating that this method can be used to differentiate among individual drug batches and subsequently identify counterfeits on the market. On the other hand, carbon isotopic ratios differences among producers were recorded, the variations being between ?31.3 to ?34.9% for the same type of analgesic, but from different manufactures.

  1. Lambda Station: Alternate network path forwarding for production SciDAC applications

    SciTech Connect (OSTI)

    Grigoriev, Maxim; Bobyshev, Andrey; Crawford, Matt; DeMar, Phil; Grigaliunas, Vyto; Moibenko, Alexander; Petravick, Don; /Fermilab; Newman, Harvey; Steenberg, Conrad; Thomas, Michael; /Caltech

    2007-09-01T23:59:59.000Z

    The LHC era will start very soon, creating immense data volumes capable of demanding allocation of an entire network circuit for task-driven applications. Circuit-based alternate network paths are one solution to meeting the LHC high bandwidth network requirements. The Lambda Station project is aimed at addressing growing requirements for dynamic allocation of alternate network paths. Lambda Station facilitates the rerouting of designated traffic through site LAN infrastructure onto so-called 'high-impact' wide-area networks. The prototype Lambda Station developed with Service Oriented Architecture (SOA) approach in mind will be presented. Lambda Station has been successfully integrated into the production version of the Storage Resource Manager (SRM), and deployed at US CMS Tier1 center at Fermilab, as well as at US-CMS Tier-2 site at Caltech. This paper will discuss experiences using the prototype system with production SciDAC applications for data movement between Fermilab and Caltech. The architecture and design principles of the production version Lambda Station software, currently being implemented as Java based web services, will also be presented in this paper.

  2. Exposure to methyl tert-butyl ether and benzene among service station attendants and operators

    SciTech Connect (OSTI)

    Hartle, R. [National Inst. for Occupational Safety and Health, Cincinnati, OH (United States)

    1993-12-01T23:59:59.000Z

    Concerns for atmospheric pollution from auto exhaust have led to the blending of {open_quotes}oxygenates{close_quotes} with motor fuels. The most common oxygenate, methyl tert-butyl ether (MTBE) is currently required within several metropolitan areas (Denver and Phoenix) in the range of 12% of the motor fuel. Amendments to the Clean Air Act may expand this requirement to as many as 44 other areas of the United States in the near future. In consideration of the magnitude of potential uncontrolled exposures from its extensive use and a related concern involving the potential influence of MTBE blending on exposures to other constituents of gasoline (particularly benzene), an evaluation of exposures among service station attendants and operators was undertaken at the request, and in cooperation with, the American Petroleum Institute during the latter part of 1990. For application of the survey results to a broad audience, three categories or types of service stations were identified with regard to MTBE use and exposure potential: (a) service stations that do not use MTBE or use it only as an octane enhancer, (b) service stations with seasonal requirements to use 12-15% MTBE (the Denver, Colorado, and Phoenix, Arizona, metropolitan areas), and (c) service stations equipped with stage II (active) vapor recovery systems (several coastal areas, most notably Southern California). 4 refs., 4 tabs.

  3. On Deployment of Multiple Base Stations for Energy-Efficient Communication in Wireless Sensor Networks

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Lin, Yunyue; Wu, Qishi; Cai, Xiaoshan; Du, Xiaojiang; Kwon, Ki-Hyeon

    2010-01-01T23:59:59.000Z

    Data transmission from sensor nodes to a base station or a sink node often incurs significant energy consumption, which critically affects network lifetime. We generalize and solve the problem of deploying multiple base stations to maximize network lifetime in terms of two different metrics under one-hop and multihop communication models. In the one-hop communication model, the sensors far away from base stations always deplete their energy much faster than others. We propose an optimal solution and a heuristic approach based on the minimal enclosing circle algorithm to deploy a base station at the geometric center of each cluster. In themore »multihop communication model, both base station location and data routing mechanism need to be considered in maximizing network lifetime. We propose an iterative algorithm based on rigorous mathematical derivations and use linear programming to compute the optimal routing paths for data transmission. Simulation results show the distinguished performance of the proposed deployment algorithms in maximizing network lifetime.« less

  4. air-fuel ratio control: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    was performed to investigate the effects of air-fuel ratio, inlet boost pressure, hydrogen rich fuel reformate, and compression ratio on engine knock behavior. For each...

  5. Isotope Ratio Analysis on Micron-Sized Particles in Complex Matrices by Laser Ablation – Absorption Ratio Spectrometry

    SciTech Connect (OSTI)

    Bushaw, Bruce A.; Anheier, Norman C.

    2009-12-01T23:59:59.000Z

    Laser ablation has been combined with dual tunable diode laser absorption spectrometry to measure 152Gd:160Gd isotope ratios in micron-size particles. The diode lasers are tuned to specific isotopes in two different atomic transitions at 405.9 nm (152Gd) and 413.4 nm (160Gd) and directed collinearly through the laser ablation plume, separated on a diffraction grating, and detected with photodiodes to monitor transient absorption signals on a shot-by-shot basis. The method has been characterized first using Gd metal foil and then with particles of GdCl3?xH20 as binary and ternary mixtures with 152Gd:160Gd isotope ratios ranging from 0.01 to 0.43. These particulate mixtures have been diluted with Columbia River sediment powder (SRM 4350B) to simulate environmental samples and we show the method is capable of detecting a few highly enriched particles in the presence of > 100-fold excess of low-enrichment particles, even when the Gd-bearing particles are a minor component (0.08%) in the SRM powder and widely dispersed (1178 particles detected in 800 000 ablation laser shots). The implications for monitoring 235U:238U enrichment ratios, as related to the nuclear industry, are discussed

  6. Control system for, and a method of, heating an operator station of a work machine

    DOE Patents [OSTI]

    Baker, Thomas M.; Hoff, Brian D.; Akasam, Sivaprasad

    2005-04-05T23:59:59.000Z

    There are situations in which an operator remains in an operator station of a work machine when an engine of the work machine is inactive. The present invention includes a control system for, and a method of, heating the operator station when the engine is inactive. A heating system of the work machine includes an electrically-powered coolant pump, a power source, and at least one piece of warmed machinery. An operator heat controller is moveable between a first and a second position, and is operable to connect the electrically-powered coolant pump to the power source when the engine is inactive and the operator heat controller is in the first position. Thus, by deactivating the engine and then moving the operator heat controller to the first position, the operator may supply electrical energy to the electrically-powered coolant pump, which is operably coupled to heat the operator station.

  7. GEOPHYSICAL INVESTIGATIONS OF THE ARCHAEOLOGICAL RESOURCES AT THE POWELL STAGE STATION

    SciTech Connect (OSTI)

    Hollie K. Gilbert; Julie B. Braun; Brenda R. Pace; Gail Heath; Clark Scott

    2009-04-01T23:59:59.000Z

    Within the boundaries of the Idaho National Laboratory, an ongoing archaeological investigation of a late 19th century stage station was expanded with the use of Electro-Magnetic and Magnetic geophysical surveying. The station known as the Powell Stage Station was a primary transportation hub on the Snake River Plain, bridging the gap between railroad supply depots in Blackfoot, Idaho and booming mining camps throughout Central Idaho. Initial investigations have shown a strong magnetic signature from a buried road and previously unknown features that were not detected by visual surface surveys. Data gained from this project aids in federally directed cultural resource and land management and use requirements and has contributed additional information for archeological interpretation and cultural resource preservation.

  8. Hanford Meteorological Station computer codes: Volume 1, The GEN computer code

    SciTech Connect (OSTI)

    Buck, J.W.; Andrews, G.L.

    1987-07-01T23:59:59.000Z

    The Hanford Meteorological Station, operated by Pacific Northwest Laboratory, issues general weather forecasts twice a day. The GEN computer code is used to archive the 24-hour forecasts and apply quality assurance checks to the forecast data. This code accesses an input file, which contains the date and hour of the previous forecast, and an output file, which contains 24-hour forecasts for the current month. As part of the program, a data entry form consisting of 14 fields that describe various weather conditions must be filled in. The information on the form is appended to the current 24-hour monthly forecast file, which provides an archive for the 24-hour general weather forecasts. This report consists of several volumes documenting the various computer codes used at the Hanford Meteorological Station. This volume describes the implementation and operation of the GEN computer code at the station.

  9. The value of auxiliary stations and the need for network calibration

    SciTech Connect (OSTI)

    Denny, M.

    1996-02-01T23:59:59.000Z

    To address the question of the value of auxiliary stations placed before the GSE by the Ad Hoc Committee on Nuclear Test Ban, we examined the published location error estimates given by both the NEIS and the IDC. The results of our analysis demonstrate the well-known principle that the uncertainty in the location for a given event decreases as the number of defining phases (or stations) increases and as the azimuthal coverage increases. More importantly, however, the results also show that the location uncertainty dramatically decreases as the distance to the nearest station decreases. We also show that the empirically observed rate of overlap of corresponding IDC and NEIS error ellipses is inconsistent with expectation as determined by statistically modeling the performance of each. To overcome this shortcoming the IMS must be calibrated.

  10. An in situ measurement of the radio-frequency attenuation in ice at Summit Station, Greenland

    E-Print Network [OSTI]

    J. Avva; J. M. Kovac; C. Miki; D. Saltzberg; A. G. Vieregg

    2014-09-30T23:59:59.000Z

    We report an in situ measurement of the electric field attenuation length at radio frequencies for the bulk ice at Summit Station, Greenland, made by broadcasting radio-frequency signals vertically through the ice and measuring the relative power in the return ground bounce signal. We find the depth-averaged field attenuation length to be 947 +92/-85 meters at 75 MHz. While this measurement has clear radioglaciological applications, the radio clarity of the ice also has implications for the detection of ultra-high energy (UHE) astrophysical particles via their radio emission in dielectric media such as ice. The measured attenuation length at Summit Station is comparable to previously measured radio-frequency attenuation lengths at candidate particle detector sites around the world, and strengthens the case for Summit Station as the most promising northern site for UHE neutrino detection.

  11. 14th Annual international meeting of wind turbine test stations: Proceedings

    SciTech Connect (OSTI)

    Not Available

    1994-11-01T23:59:59.000Z

    These proceedings are of the 14th Annual International Meeting of Test Stations. As the original charter states these meetings are intended to be an international forum for sharing wind turbine testing experiences. By sharing their experiences they can improve testing skills and techniques. As with all new industries the quality of the products is marked by how well they learn from their experiences and incorporate this learning into the next generation of products. The test station`s role in this process is to provide accurate information to the companies they serve. This information is used by designers to conform and improve their designs. It is also used by certification agencies for confirming the quality of these designs. By sharing of experiences they are able to accomplished these goals, serve these customers better and ultimately improve the international wind energy industry.

  12. Cost of Adding E85 Fueling Capability to Existing Gasoline Stations: NREL Survey and Literature Search (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2008-03-01T23:59:59.000Z

    Fact sheet provides framework for gas station owners to access what a reasonable cost would be to install E85 infrastructure.

  13. Device to facilitate moving an electrical cable of an electric vehicle charging station and method of providing the same

    DOE Patents [OSTI]

    Karner, Donald B

    2014-04-29T23:59:59.000Z

    Some embodiments include a device to facilitate moving an electrical cable of an electric vehicle charging station. Other embodiments of related systems and methods are also disclosed.

  14. Method for producing thin graphite flakes with large aspect ratios

    DOE Patents [OSTI]

    Bunnell, L. Roy (Kennewick, WA)

    1993-01-01T23:59:59.000Z

    A method for making graphite flakes of high aspect ratio by the steps of providing a strong concentrated acid and heating the graphite in the presence of the acid for a time and at a temperature effective to intercalate the acid in the graphite; heating the intercalated graphite at a rate and to a temperature effective to exfoliate the graphite in discrete layers; subjecting the graphite layers to ultrasonic energy, mechanical shear forces, or freezing in an amount effective to separate the layes into discrete flakes.

  15. Stratigraphic Profiles for Selected Hanford Site Seismometer Stations and Other Locations

    SciTech Connect (OSTI)

    Last, George V.

    2014-02-01T23:59:59.000Z

    Stratigraphic profiles were constructed for eight selected Hanford Site seismometer stations, five Hanford Site facility reference locations, and seven regional three-component broadband seismometer stations. These profiles provide interpretations of the subsurface layers to support estimation of ground motions from past earthquakes, and the prediction of ground motions from future earthquakes. In most cases these profiles terminated at the top of the Wanapum Basalt, but at selected sites profiles were extended down to the top of the crystalline basement. The composite one-dimensional stratigraphic profiles were based primarily on previous interpretations from nearby boreholes, and in many cases the nearest deep borehole is located kilometers away.

  16. Flatiron agc (automatic generation control) interim controller. Master station. Volume 1

    SciTech Connect (OSTI)

    Lennon, C.A. Jr; Whittemore, T.R.; Stitt, S.C.; Gish, W.B.

    1983-06-01T23:59:59.000Z

    The Flatiron Interim Automatic Generation Controller has been placed in service for the Lower Missouri Western Area Power Administration Control Area. This controller meets the requirements of the National Electric Reliability Council and controls the energy generation and transfers in northern Colorado, Wyoming, western Nebraska, western South Dakota, and southern Montana. The master controller is based on five interacting microprocessors with unique communication structures and data storage methods. The design, construction, maintenance, and operation details for the master station and the remote stations, including flow charts, schematics, and wiring diagrams, are in this four-volume series.

  17. Technology, Safety and Costs of Decommissioning Nuclear Reactors At Multiple-Reactor Stations

    SciTech Connect (OSTI)

    Wittenbrock, N. G.

    1982-01-01T23:59:59.000Z

    Safety and cost information is developed for the conceptual decommissioning of large (1175-MWe) pressurized water reactors (PWRs) and large (1155-MWe) boiling water reactors {BWRs) at multiple-reactor stations. Three decommissioning alternatives are studied: DECON (immediate decontamination), SAFSTOR (safe storage followed by deferred decontamination), and ENTOMB (entombment). Safety and costs of decommissioning are estimated by determining the impact of probable features of multiple-reactor-station operation that are considered to be unavailable at a single-reactor station, and applying these estimated impacts to the decommissioning costs and radiation doses estimated in previous PWR and BWR decommissioning studies. The multiple-reactor-station features analyzed are: the use of interim onsite nuclear waste storage with later removal to an offsite nuclear waste disposal facility, the use of permanent onsite nuclear waste disposal, the dedication of the site to nuclear power generation, and the provision of centralized services. Five scenarios for decommissioning reactors at a multiple-reactor station are investigated. The number of reactors on a site is assumed to be either four or ten; nuclear waste disposal is varied between immediate offsite disposal, interim onsite storage, and immediate onsite disposal. It is assumed that the decommissioned reactors are not replaced in one scenario but are replaced in the other scenarios. Centralized service facilities are provided in two scenarios but are not provided in the other three. Decommissioning of a PWR or a BWR at a multiple-reactor station probably will be less costly and result in lower radiation doses than decommissioning an identical reactor at a single-reactor station. Regardless of whether the light water reactor being decommissioned is at a single- or multiple-reactor station: • the estimated occupational radiation dose for decommissioning an LWR is lowest for SAFSTOR and highest for DECON • the estimated cost of decommissioning a PWR is lowest for ENTOMB and highest for SAFSTOR • the estimated cost of decommissioning a BWR is lowest for OECON and highest for SAFSTOR. In all cases, SAFSTOR has the lowest occupational radiation dose and the highest cost.

  18. Evaluation of the effectiveness of shielding and filtering of HVDC converter stations

    SciTech Connect (OSTI)

    Dallaire, R.D.; Maruvada, P.S.

    1989-04-01T23:59:59.000Z

    The electromagnetic interference (EMI) generated by the periodic turn-on and turn-off of the valves is an important consideration in the design of HVDC converter stations. Remedial measures such as shielding the valve hall and filtering have been used in order to reduce the interference levels to acceptable values. The application of recently-developed Numerical Electromagnetic Code (NEC) to the problem of EMI from HVDC converter stations is investigated in this paper, with particular emphasis on evaluating the effectiveness of valve hall shielding and filtering.

  19. Design of a photovoltaic central power station: flat-plate array

    SciTech Connect (OSTI)

    Not Available

    1984-02-01T23:59:59.000Z

    A design for a photovoltaic central power station using fixed flat-panel arrays has been developed. The 100 MW plant is assumed to be located adjacent to the Saguaro Power Station of Arizona Public Service. The design assumes high-efficiency photovoltaic modules using dendritic web cells. The modules are arranged in 5 MW subfields, each with its own power conditioning unit. The photovoltaic output is connected to the existing 115 kV utility switchyard. The site specific design allows detailed cost estimates for engineering, site preparation, and installation. Collector and power conditioning costs have been treated parametrically.

  20. Cosmic ray muon charge ratio in the MINOS far detector

    SciTech Connect (OSTI)

    Beall, Erik B; /Minnesota U.

    2005-12-01T23:59:59.000Z

    The MINOS Far Detector is a 5.4 kiloton (5.2 kt steel plus 0.2 kt scintillator plus aluminum skin) magnetized tracking calorimeter located 710 meters underground in the Soudan mine in Northern Minnesota. MINOS is the first large, deep underground detector with a magnetic field and thus capable of making measurements of the momentum and charge of cosmic ray muons. Despite encountering unexpected anomalies in distributions of the charge ratio (N{sub {mu}{sup +}}/N{sub {mu}{sup -}}) of cosmic muons, a method of canceling systematic errors is proposed and demonstrated. The result is R{sub eff} = 1.346 {+-} 0.002 (stat) {+-} 0.016 (syst) for the averaged charge ratio, and a result for a rising fit to slant depth of R(X) = 1.300 {+-} 0.008 (stat) {+-} 0.016 (syst) + (1.8 {+-} 0.3) x 10{sup -5} x X, valid over the range of slant depths from 2000 < X < 6000 MWE. This slant depth range corresponds to minimum surface muon energies between 750 GeV and 5 TeV.

  1. Spherical codes, maximal local packing density, and the golden ratio

    E-Print Network [OSTI]

    A. B. Hopkins; F. H. Stillinger; S. Torquato

    2010-03-18T23:59:59.000Z

    The densest local packing (DLP) problem in d-dimensional Euclidean space Rd involves the placement of N nonoverlapping spheres of unit diameter near an additional fixed unit-diameter sphere such that the greatest distance from the center of the fixed sphere to the centers of any of the N surrounding spheres is minimized. Solutions to the DLP problem are relevant to the realizability of pair correlation functions for packings of nonoverlapping spheres and might prove useful in improving upon the best known upper bounds on the maximum packing fraction of sphere packings in dimensions greater than three. The optimal spherical code problem in Rd involves the placement of the centers of N nonoverlapping spheres of unit diameter onto the surface of a sphere of radius R such that R is minimized. It is proved that in any dimension, all solutions between unity and the golden ratio to the optimal spherical code problem for N spheres are also solutions to the corresponding DLP problem. It follows that for any packing of nonoverlapping spheres of unit diameter, a spherical region of radius less than or equal to the golden ratio centered on an arbitrary sphere center cannot enclose a number of sphere centers greater than one more than the number that can be placed on the region's surface.

  2. Analysis of fragment yield ratios in the nuclear phase transition

    E-Print Network [OSTI]

    R. Tripathi; A. Bonasera; S. Wuenschel; L. W. May; Z. Kohley; G. A. Souliotis; S. Galanopoulos; K. Hagel; D. V. Shetty; K. Huseman; S. N. Soisson; B. C. Stein; S. J. Yennello

    2010-10-11T23:59:59.000Z

    The critical phenomena of the liquid-gas phase transition has been investigated in the reactions 78,86Kr+58,64Ni at beam energy of 35 MeV/nucleon using the Landau free energy approach with isospin asymmetry as an order parameter. Fits to the free energy of fragments showed three minima suggesting the system to be in the regime of a first order phase transition. The relation m =-{\\partial}F/{\\partial}H, which defines the order parameter and its conjugate field H, has been experimentally verified from the linear dependence of the mirror nuclei yield ratio data, on the isospin asymmetry of the source. The slope parameter, which is a measure of the distance from a critical temperature, showed a systematic decrease with increasing excitation energy of the source. Within the framework of the Landau free energy approach, isoscaling provided similar results as obtained from the analysis of mirror nuclei yield ratio data. We show that the external field is primarily related to the minimum of the free energy, which implies a modification of the source concentration \\Delta used in isospin studies.

  3. New Curved Spacetime Dirac Equations - On the Anomalous Gyromagnetic Ratio

    E-Print Network [OSTI]

    G. G. Nyambuya

    2008-09-06T23:59:59.000Z

    I propose three new curved spacetime versions of the Dirac Equation. These equations have been developed mainly to try and account in a natural way for the observed anomalous gyromagnetic ratio of Fermions. The derived equations suggest that particles including the Electron which is thought to be a point particle do have a finite spatial size which is the reason for the observed anomalous gyromagnetic ratio. A serendipitous result of the theory, is that, two of the equation exhibits an asymmetry in their positive and negative energy solutions the first suggestion of which is clear that a solution to the problem as to why the Electron and Muon - despite their acute similarities - exhibit an asymmetry in their mass is possible. The Mourn is often thought as an Electron in a higher energy state. Another of the consequences of three equations emanating from the asymmetric serendipity of the energy solutions of two of these equations, is that, an explanation as to why Leptons exhibit a three stage mass hierarchy is possible.

  4. Shear Viscosity to Entropy Density Ratio in Six Derivative Gravity

    E-Print Network [OSTI]

    Nabamita Banerjee; Suvankar Dutta

    2009-04-01T23:59:59.000Z

    We calculate shear viscosity to entropy density ratio in presence of four derivative (with coefficient $\\alpha'$) and six derivative (with coefficient $\\alpha'^2$) terms in bulk action. In general, there can be three possible four derivative terms and ten possible six derivative terms in the Lagrangian. Among them two four derivative and eight six derivative terms are ambiguous, i.e., these terms can be removed from the action by suitable field redefinitions. Rest are unambiguous. According to the AdS/CFT correspondence all the unambiguous coefficients (coefficients of unambiguous terms) can be fixed in terms of field theory parameters. Therefore, any measurable quantities of boundary theory, for example shear viscosity to entropy density ratio, when calculated holographically can be expressed in terms of unambiguous coefficients in the bulk theory (or equivalently in terms of boundary parameters). We calculate $\\eta/s$ for generic six derivative gravity and find that apparently it depends on few ambiguous coefficients at order $\\alpha'^2$. We calculate six derivative corrections to central charges $a$ and $c$ and express $\\eta/s$ in terms of these central charges and unambiguous coefficients in the bulk theory.

  5. Tissue phantom ratios for a Clinac 4/100

    SciTech Connect (OSTI)

    Biggs, P.J.; Doppke, K.P.; Leong, J.C.; Russell, M.D.

    1982-09-01T23:59:59.000Z

    Tissue phantom ratios (TPR), based on a normalization depth of 5 cm, have been measured in water for field sizes from 5 x 5 cm/sup 2/ to approximately 40 x 40 cm/sup 2/ and for depths from 1 to 40 cm for a Varian Clinac 4/100. These TPR's have been compared with those calculated from percent depth doses measured at the same time, and the two sets of data generally agree to better than 1%, with an average ratio of measured to calculated TPR of 0.999 +- 0.013. Beam profiles have been measured for open and wedged fields, with particular concern for the often observed ''horns,'' or the increase in dose at the corners of the field. The maximum dose at a depth of 1 cm, along the diagonal of the field for this machine, is approximately 5% higher than at the same depth on the central axis, whereas along the principal plane the maximum dose is only about 3% higher.

  6. Bound for entropy and viscosity ratio for strange quark matter

    E-Print Network [OSTI]

    Manjari Bagchi; Jishnu Dey; Mira Dey; Taparati Gangopadhyay; Sibasish Laha; Subharthi Ray; Monika Sinha

    2008-07-03T23:59:59.000Z

    High energy density ($\\eps$) and temperature (T) links general relativity and hydrodynamics leading to a lower bound for the ratio of shear viscosity ($\\eta$) and entropy density ($s$). We get the interesting result that the bound is saturated in the simple model for quark matter that we use for strange stars at the surface for $T \\sim 80 MeV$. At this $T$ we have the possibility of cosmic separation of phases. At the surface of the star where the pressure is zero - the density $\\eps$ has a fixed value for all stars of various masses with correspondingly varying central energy density $\\eps_c$. Inside the star where this density is higher, the ratio of $\\eta/s$ is larger and are like the known results found for perturbative QCD. This serves as a check of our calculation. The deconfined quarks at the surface of the strange star at $T = 80 MeV$ seem to constitute the most perfect interacting fluid permitted by nature.

  7. ARM: 10-second Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Sivaraman, Chitra; Flynn, Connor

    10-second Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm

  8. ARM: 2-minute Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Sivaraman, Chitra; Flynn, Connor

    2-minute Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm

  9. ARM: 10-minute Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Newsom, Rob; Goldsmith, John

    10-minute Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm

  10. ARM: 1-minute Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Sivaraman, Chitra; Flynn, Connor

    1-minute Raman Lidar: aerosol scattering ratio and backscattering coefficient profiles, from first Ferrare algorithm

  11. Field Testing of Activated Carbon Injection Options for Mercury Control at TXU's Big Brown Station

    SciTech Connect (OSTI)

    John Pavlish; Jeffrey Thompson; Christopher Martin; Mark Musich; Lucinda Hamre

    2009-01-07T23:59:59.000Z

    The primary objective of the project was to evaluate the long-term feasibility of using activated carbon injection (ACI) options to effectively reduce mercury emissions from Texas electric generation plants in which a blend of lignite and subbituminous coal is fired. Field testing of ACI options was performed on one-quarter of Unit 2 at TXU's Big Brown Steam Electric Station. Unit 2 has a design output of 600 MW and burns a blend of 70% Texas Gulf Coast lignite and 30% subbituminous Powder River Basin coal. Big Brown employs a COHPAC configuration, i.e., high air-to-cloth baghouses following cold-side electrostatic precipitators (ESPs), for particulate control. When sorbent injection is added between the ESP and the baghouse, the combined technology is referred to as TOXECON{trademark} and is patented by the Electric Power Research Institute in the United States. Key benefits of the TOXECON configuration include better mass transfer characteristics of a fabric filter compared to an ESP for mercury capture and contamination of only a small percentage of the fly ash with AC. The field testing consisted of a baseline sampling period, a parametric screening of three sorbent injection options, and a month long test with a single mercury control technology. During the baseline sampling, native mercury removal was observed to be less than 10%. Parametric testing was conducted for three sorbent injection options: injection of standard AC alone; injection of an EERC sorbent enhancement additive, SEA4, with ACI; and injection of an EERC enhanced AC. Injection rates were determined for all of the options to achieve the minimum target of 55% mercury removal as well as for higher removals approaching 90%. Some of the higher injection rates were not sustainable because of increased differential pressure across the test baghouse module. After completion of the parametric testing, a month long test was conducted using the enhanced AC at a nominal rate of 1.5 lb/Macf. During the time that enhanced AC was injected, the average mercury removal for the month long test was approximately 74% across the test baghouse module. ACI was interrupted frequently during the month long test because the test baghouse module was bypassed frequently to relieve differential pressure. The high air-to-cloth ratio of operations at this unit results in significant differential pressure, and thus there was little operating margin before encountering differential pressure limits, especially at high loads. This limited the use of sorbent injection as the added material contributes to the overall differential pressure. This finding limits sustainable injection of AC without appropriate modifications to the plant or its operations. Handling and storage issues were observed for the TOXECON ash-AC mixture. Malfunctioning equipment led to baghouse dust hopper plugging, and storage of the stagnant material at flue gas temperatures resulted in self-heating and ignition of the AC in the ash. In the hoppers that worked properly, no such problems were reported. Economics of mercury control at Big Brown were estimated for as-tested scenarios and scenarios incorporating changes to allow sustainable operation. This project was funded under the U.S. Department of Energy National Energy Technology Laboratory project entitled 'Large-Scale Mercury Control Technology Field Testing Program--Phase II'.

  12. Evaluation of trends in high temperature extremes in north-western Europe in regional climate This article has been downloaded from IOPscience. Please scroll down to see the full text article.

    E-Print Network [OSTI]

    Haak, Hein

    . There is also no significant correlation between the RCM Tann.max trends and trends in radiation or Bowen ratio of the work, journal citation and DOI. number of regions in the world (Clark et al 2006, Fischer and Sch

  13. AgExcellence 2006 The College of Agriculture and Montana Agricultural Experiment Station in Review

    E-Print Network [OSTI]

    Maxwell, Bruce D.

    AgExcellence 2006 The College of Agriculture and Montana Agricultural Experiment Station in Review #12;ACAdEMiC pRogRAMS College of Agriculture Baccalaureate: Agricultural Education Options: AgRelations Teaching Agricultural Operations Technology MasterofScience: Agricultural Education Baccalaureate

  14. Improvement of the European Wind Atlas Method by Spatial Interpolation of Meteorological Station Data

    E-Print Network [OSTI]

    Heinemann, Detlev

    Improvement of the European Wind Atlas Method by Spatial Interpolation of Meteorological Station. Introduction The European Wind Atlas in combination with the Wind Atlas Analysis and Application Program (WAs (DEWI), EbertstraĂ?e 96, D-26382 Wilhelmshaven, Germany Abstract The practice of using the European Wind

  15. Flywheel-Based Distributed Bus Signalling Strategy for the Public Fast Charging Station

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    1 Flywheel-Based Distributed Bus Signalling Strategy for the Public Fast Charging Station Tomislav to intolerable stresses in the near future scenario where there will be a large number of public FCS spread across the network. This paper proposes an internal power balancing strategy for FCS based on flywheel

  16. Rendezvous Design Algorithms for Wireless Sensor Networks with a Mobile Base Station

    E-Print Network [OSTI]

    of controlled mobil- ity and in-network data caching and can achieve a desirable balance between network energy; Tian Wang; Weijia Jia; Minming Li Deptment of Computer Science, City University of Hong Kong 83 Tat that significant energy saving can be achieved in wireless sensor networks with a mobile base station that collects

  17. Successes, Challenges, Lessons Learned in Land Use Planning Efforts Adjacent to an LRT Station

    E-Print Network [OSTI]

    Minnesota, University of

    Successes, Challenges, Lessons Learned in Land Use Planning Efforts Adjacent to an LRT Station interest in "new outreach methods" ·!Demonstrated value added in more collaborative process #12;Lessons Learned 1.! Begin internal & external outreach earlier 2.! Our "good ideas" were not necessarily good

  18. The effects of solar-geomagnetically induced currents on electrical systems in nuclear power stations

    SciTech Connect (OSTI)

    Subudhi, M. [Brookhaven National Lab., Upton, NY (United States)] [Brookhaven National Lab., Upton, NY (United States); Carroll, D.P. [Florida Univ., Gainesville, FL (United States)] [Florida Univ., Gainesville, FL (United States); Kasturi, S. [MOS, Inc., Melville, NY (United States)] [MOS, Inc., Melville, NY (United States)

    1994-01-01T23:59:59.000Z

    This report presents the results of a study to evaluate the potential effects of geomagnetically induced currents (GICs) caused by the solar disturbances on the in-plant electrical distribution system and equipment in nuclear power stations. The plant-specific electrical distribution system for a typical nuclear plant is modeled using the ElectroMagnetic Transient Program (EMTP). The computer model simulates online equipment and loads from the station transformer in the switchyard of the power station to the safety-buses at 120 volts to which all electronic devices are connected for plant monitoring. The analytical model of the plant`s electrical distribution system is studied to identify the transient effects caused by the half-cycle saturation of the station transformers due to GIC. This study provides results of the voltage harmonics levels that have been noted at various electrical buses inside the plant. The emergency circuits appear to be more susceptible to high harmonics due to the normally light load conditions. In addition to steady-state analysis, this model was further analyzed simulating various plant transient conditions (e.g., loss of load or large motor start-up) occurring during GIC events. Detail models of the plant`s protective relaying system employed in bus transfer application were included in this model to study the effects of the harmonic distortion of the voltage input. Potential harmonic effects on the uniterruptable power system (UPS) are qualitatively discussed as well.

  19. Guide for Identifying and Converting High-Potential Petroleum Brownfield Sites to Alternative Fuel Stations

    SciTech Connect (OSTI)

    Johnson, C.; Hettinger, D.; Mosey, G.

    2011-05-01T23:59:59.000Z

    Former gasoline stations that are now classified as brownfields can be good sites to sell alternative fuels because they are in locations that are convenient to vehicles and they may be seeking a new source of income. However, their success as alternative fueling stations is highly dependent on location-specific criteria. First, this report outlines what these criteria are, how to prioritize them, and then applies that assessment framework to five of the most popular alternative fuels--electricity, natural gas, hydrogen, ethanol, and biodiesel. The second part of this report delves into the criteria and tools used to assess an alternative fuel retail site at the local level. It does this through two case studies of converting former gasoline stations in the Seattle-Eugene area into electric charge stations. The third part of this report addresses steps to be taken after the specific site has been selected. This includes choosing and installing the recharging equipment, which includes steps to take in the permitting process and key players to include.

  20. MSL F693 F01 French Tidal Power CRN # 36273 Station

    E-Print Network [OSTI]

    Kowalik, Zygmunt

    MSL F693 F01 French Tidal Power CRN # 36273 Station 3 CREDITS Zygmunt Kowalik A new course on TIDES. Such application has raised many questions about an environmental impact of tidal power development. The course a function of the changes in the sun- earth-moon system, caused by dissipation of the tidal energy

  1. STANFORD AMATEUR RADIO STATION W6YX PRESS RELEASE June 19, 2008

    E-Print Network [OSTI]

    Straight, Aaron

    Relay League (ARRL, www.arrl.org), the national association for Amateur Radio (a.k.a. "ham radio was designed to test operators' abilities to set up and operate portable stations under emergency conditions, fire, the Red Cross, and other agencies." Field Day is a serious test of skill, but it is also

  2. College of Agriculture and Life Sciences The NewYork State Agricultural Experiment Station

    E-Print Network [OSTI]

    and the College of Agriculture and Life Sciences The NewYork State Agricultural Experiment Station Food Economy Strengthening Farms #12;Agricultural Research for 21st Century Needs Dear Friends, "The overlooked economic engine"--that's how a 2012 Farm Credit East study describes the status of agriculture

  3. State of structures of the Kolyma hydroelectric station according to data of on-site observations

    SciTech Connect (OSTI)

    Kuznetsov, V.S.; Voinovich, A.P.; Matroshilina, T.V.; Krupin, V.A.; Bulatov, S.N.

    1995-10-01T23:59:59.000Z

    On-site inspections of the Kolyma hydroelectric power station have been performed since 1979. A large quantity of data has been obtained pertaining to the dam, underground powerhouse, and other structures. Over 2000 measuring instruments were installed for checking the structures and foundations.

  4. Analysis of Multi-Server Queues with Station and Server Vacations

    E-Print Network [OSTI]

    Zhao, Yiqiang Q.

    Analysis of Multi-Server Queues with Station and Server Vacations Xiuli Chao Department and server vacation. In the first one, all the servers take vacation si- multaneously whenever the system vacation for all servers. This phe- nomenon occurs in practice, for example, when the system consists

  5. A newsletter of the Kemp Natural Resources Station Volume 4, Number 1 -Spring 2003

    E-Print Network [OSTI]

    raised concern about the potential impacts on sustainable resource use. Such concern often spawnsA newsletter of the Kemp Natural Resources Station Volume 4, Number 1 - Spring 2003 (Continued, and many settlers inundated the area. The poor soils and short growing season caused many farms to fail

  6. INHERENT WATER OPTICAL PROPERTIES AT THE CARIBBEAN TIME SERIES STATION (CaTS)

    E-Print Network [OSTI]

    Gilbes, Fernando

    INHERENT WATER OPTICAL PROPERTIES AT THE CARIBBEAN TIME SERIES STATION (CaTS) Fernando Gilbes Rico 00681 ABSTRACT The temporal variability of the inherent water optical properties at the Caribbean wavelengths, but in all cases, the values were less than one. The correlation between bio-optical properties

  7. Agricultural Experiment Station SP701-A Growing and Harvesting Switchgrass for

    E-Print Network [OSTI]

    Grissino-Mayer, Henri D.

    Agricultural Experiment Station SP701-A Growing and Harvesting Switchgrass for Ethanol Production feedstock for ethanol production. It is anticipated that switchgrass can yield sufficient biomass to produce approximately 500 gal- lons of ethanol per acre. While the Tennessee Biofuels Initiative includes

  8. Meteorology A network of 14 meteorological stations was installed across the Annapurna range before

    E-Print Network [OSTI]

    Festa-Bianchet, Marco

    on the longest record available from each station. Apatite fission-track dating Following mineral separation, apatites were polished, etched and irradiated. Standard and induced track densities were determined on Brazil ruby muscovite external detectors (geometry factor 0.5), and fossil track densities were

  9. Comments on: Antarctic Automatic Weather Station Program: 30 Years of Polar Observations

    E-Print Network [OSTI]

    Sienicki, Krzysztof

    2013-01-01T23:59:59.000Z

    Recently Lazzara et al. (2012) presented a review of the technical and scientific progress in deployment, data collection and analysis of the Automated Weather Stations (AWS) in the Antarctic. In the subsection entitled Science Applications using AWS Observations, the authors briefly account for several scientific occurrences of meteorological data collected by AWS.

  10. National Aeronautics and Space Administration International Space Station Photosynth Scavenger Hunt

    E-Print Network [OSTI]

    .nasa.gov INTERNATIONAL SPACE STATION (ISS) INTERACTIVE REFERENCE GUIDE National Aeronautics and Space Administration U and outfitting Exterior Aluminum, 3 cylindrical sec- tions, 2 endcones Number of racks 24 (13 scientific and 11-98 Module in preparation at Marshall Space Flight Center (MSFC). #12;

  11. Activate the nearest fire alarm pull station Call 911 to report the fire

    E-Print Network [OSTI]

    Azevedo, Ricardo

    as designated by emergency responders, well away from the building. Do not touch or disturb the objectActivate the nearest fire alarm pull station Call 911 to report the fire Notify and assist people not re-enter the building until authorized to do so by emergency personnel. When the fire alarm

  12. IV. STATION CONFIGURATION AND SENSOR COMPARISONS Comparison of solar radiation data gathered at

    E-Print Network [OSTI]

    Oregon, University of

    8 IV. STATION CONFIGURATION AND SENSOR COMPARISONS Comparison of solar radiation data gathered of the instruments used to monitor the incident solar radiation. Five types of so- lar sensors and several different data loggers have been used to gather the solar radiation data presented in this data book

  13. Solar Radiation Prediction and Energy Allocation for Energy Harvesting Base Stations

    E-Print Network [OSTI]

    Solar Radiation Prediction and Energy Allocation for Energy Harvesting Base Stations Yanan Bao@tsinghua.edu.cn Abstract--In this paper, we study how to use the solar radiation model to predict energy arrivals solar radiation is reviewed and summarized. We present two solar energy models for cloudless days

  14. Integrating GIS and World Wide Web for local elections -- a case study in College Station, Texas

    E-Print Network [OSTI]

    Shi, Bing

    2000-01-01T23:59:59.000Z

    Multiple Clients Figure 1. Simplified Architecture of College Station Voting Information System 35 MIMI1 CAMI NO CAND FN CAND LA jp fP illslf VonBR ND N02 NQB N09 N010 N020 N024 N028 N031 N032 N033 34 9 40 RLVVOTE LLOTSUM ECT...

  15. Solar Radiation Monitoring Station (SoRMS): Humboldt State University, Arcata, California (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Wilcox, S.; Andreas, A.

    A partnership with HSU and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location.

  16. Intelligent Voltage and Reactive Power Control of Mini-Hydro Power Stations for Maximisation of Real

    E-Print Network [OSTI]

    Harrison, Gareth

    1 Intelligent Voltage and Reactive Power Control of Mini-Hydro Power Stations for Maximisation Control (APFC) modes. The ability to export active and reactive power from mini-hydro power generators electrical power generation from renewable resources. Additionally, the potential early retiral of central

  17. SEAWIFS VALIDATION AT THE CARIBBEAN TIME SERIES STATION (CATS) Jess Lee-Borges* and Roy Armstrong

    E-Print Network [OSTI]

    Gilbes, Fernando

    SEAWIFS VALIDATION AT THE CARIBBEAN TIME SERIES STATION (CATS) JesĂşs Lee-Borges* and Roy Armstrong. This is of particular importance to areas such as the Eastern Caribbean which has traditionally been viewed the dynamic nature of the northeastern Caribbean, underscoring the significant effect of periodic intrusions

  18. The status and prospective of environmental radiation monitoring stations in Saudi Arabia

    SciTech Connect (OSTI)

    Al-Kheliewi, Abdullah S. [National Center for Radiation Protection, King Abdulaziz City for Science and Technology, 11442 Riyadh (Saudi Arabia); Holzheimer, Clous [ENVINET GmbH, Environmental Radiation Detection, Hans-Pinsel-Straße 4, 85540 Haar (Munich) (Germany)

    2014-09-30T23:59:59.000Z

    The use of nuclear technology requires an environmental monitoring program to ensure the safety of the environment, and to protect people from the hazards of radioactive materials, and nuclear accidents. Nuclear accidents are unique, for they incur effects that surpass international frontiers, and can even have a long lasting impact on Earth. Such was the case of the Chernobyl accident in the Ukraine on April 6, 1986. For that purpose, international and national efforts come together to observe for any nuclear or radioactive accident. Many states, including Saudi Arabia which oversees the operation of the National Radiation, Environmental and Early Monitoring Stations, The Radiation Monitoring Stations(RMS’s) are currently scattered across 35 cities in the country,. These locations are evaluated based on various technological criteria such as border cities, cities of high population density, wind direction, etc. For new nuclear power plants hovering around, it is strongly recommended to increase the number of radiation monitoring stations to warn against any threat that may arise from a nuclear leak or accident and to improve the performance of the existing RMS’s. SARA (Spectroscopic Monitoring Station for air) should be implemented due to the high sensitivity to artificial radiation, automatic isotope identification, free of maintenance, and fully independent due to solar power supply (incl. battery backup) and wireless communication (GPRS)

  19. Assessing the viability of level III electric vehicle rapid-charging stations

    E-Print Network [OSTI]

    Gogoana, Radu

    2010-01-01T23:59:59.000Z

    This is an analysis of the feasibility of electric vehicle rapid-charging stations at power levels above 300 kW. Electric vehicle rapid-charging (reaching above 80% state-of-charge in less than 15 minutes) has been ...

  20. Brussels, Belgium, November 19-22, 2012 Energy Demand Prediction in a Charge Station: A

    E-Print Network [OSTI]

    Boyer, Edmond

    EEVC Brussels, Belgium, November 19-22, 2012 Energy Demand Prediction in a Charge Station over a real database which can be associated with the energy demand generated by electric vehicles simplifying assumptions about the EV drivers' energy demand. To improve the accuracy of the modelling

  1. Diary 16 -24 September 2013 A bonus week at the Zackenberg station

    E-Print Network [OSTI]

    their parade towards the showers in building 9. However, there was no severe water shortage at this time restricted water usage. The water level in the river falls and night temperatures drop below zero creating ice. This hinders the water intake from the river to fill up the fresh water reservoirs at the station

  2. Qualification of Class 1E static battery charges and inverters for nuclear power generating stations

    SciTech Connect (OSTI)

    Not Available

    1981-01-01T23:59:59.000Z

    This standard describes methods for qualifying static battery chargers and inverters for Class 1E installations in environmentally controlled areas outside containment in nuclear power generating stations. The purpose of this standard is to provide specific procedures to meet the requirements of IEEE Std. 323-1974.

  3. Rate Adaptation and Base Station Reconfiguration for Battery Efficient Video Download

    E-Print Network [OSTI]

    Dey, Sujit

    dynamically depending on battery and buffer levels of the mobile device, the channel conditions experienced conditions so as to avoid stalling, and do not consider the effect of video download on mobile device batteryRate Adaptation and Base Station Reconfiguration for Battery Efficient Video Download Ranjini

  4. Pressures on Arizona Water and Energy Policy: Case Study of the Navajo Generating Station

    E-Print Network [OSTI]

    Fay, Noah

    largest user of energy in the state of Arizona. It is powered by a coal plant in Northern Arizona, the Navajo Generating Station (NGS), that is among the dirtiest coal power plants in the country. The future of this power plant is currently being debated by the U.S. Environmental Protection Agency (EPA

  5. Seventh annual report of the Texas Agricultural Experiment Station for the year 1894. 

    E-Print Network [OSTI]

    Connell, J. H.; Harrington, H. H.; Francis, M.; Price, R. H.; Adriance, Duncan; Clayton, James

    1895-01-01T23:59:59.000Z

    . ............................................... J. H. CONNELL, M. SC Director. ......................................... H. H. HARRINGTON, M. SC.. Chemist. ......................................... M. FRANCIS, D. V. 3f ..Veterinarian. .......................................... R. H. PRICE, B... submitted, M. FRANCIS, Veterinar ian. REPORT OF THE HORTICULTURIST. 1 COLTXGE STATION, TEXAS, January 12, 1895. J. H. Connell, Directo: : DEAR SIR-In accordance with your request, I present herewith the report of the Department of Horticulture...

  6. Retrofit precipitators mounted on $28-million deck structure constructed over highway. [Ohio Edison Co. , Sammis station

    SciTech Connect (OSTI)

    Kudich, R.L.; Kirchner, P.N.

    1983-04-01T23:59:59.000Z

    Space problems resulted in a 900-foot concrete deck to hold retrofitted precipitators that collect particulates from the Ohio Edison's largest power station. Because the deck spans a state highway, a tight construction schedule was met using a bonus/penalty agreement. Design considerations included an open construction and riverbank work. 5 figures. (DCK)

  7. A Flow Level Perspective on Base Station Power Allocation in Green Networks

    E-Print Network [OSTI]

    Boyer, Edmond

    the energy-efficiency of base stations operating in the downlink. The energy-efficiency refers to the amount nature of users (referred to as the global energy-efficiency). We emphasize our numerical results that study the influence of the radio conditions, transmit power and the user traffic on the energy-efficiency

  8. A multi-display viewing station that increases productivity and saves space

    E-Print Network [OSTI]

    Saskatchewan, University of

    A multi-display viewing station that increases productivity and saves space Conserve desk space) per monitor · Low-profile base saves desk space · Durable aluminum and steel construction creates that are VESA® MIS-D, 100/75, C compliant · Five-year warranty Product Sheet Space-saving desk stands Ergotron

  9. Report of Beeville Station (Number 4) Cabbage -- Fertilixers, Varieties, Shipping, Cauliflower -- Varities, Shipping.

    E-Print Network [OSTI]

    Pittuck, B. C; McHenry, S. A.

    1900-01-01T23:59:59.000Z

    . TEXAS AGRICULTURAL EXPERIXENT STATIONS. I pains in 'bhe growing of Ithis oabbage, but ilt eh~ams mnclusively what the Stab can do in hhe producing 'of vegetablles, ,when proper methods iaTe applied. Mr. Garth, and Mir. Baker, who lis oonneated wit...

  10. Asian emissions of CO and NOx: Constraints from aircraft and Chinese station data

    E-Print Network [OSTI]

    Palmer, Paul

    Asian emissions of CO and NOx: Constraints from aircraft and Chinese station data Yuxuan X. Wang to constrain estimates of Asian emissions of CO and NOx. A priori emissions are based on a detailed bottom emissions of CO and NOx, respectively, distributed heterogeneously, with the largest adjustments required

  11. Institute of Industrial Science, The University of Tokyo Chiba Experiment Station

    E-Print Network [OSTI]

    Tokyo, University of

    years some 30 laboratories have been engaged in approximately 60 projects at the Station. Outline Experimental Intersection Geothermal HVAC System Laboratory 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 experimental facilities such as model domes, geothermal air- conditioning system employing a ground heat

  12. Structural rehabilitation of a fossil power station after major fire damage

    SciTech Connect (OSTI)

    Freskakis, G.N.; Archer, J.C. (Burns and Roe, Inc., Oradell, NJ (USA)); Shipskie, W.P. (Seminole Electric Cooperative, Inc., Tampa, FL (US))

    1989-01-01T23:59:59.000Z

    This paper discusses the eruption and course of a fire at a fossil power station. Focus is on the damage to the building and the reinforced concrete pedestal, and the assessments and repairs involved in the restoration. Emphasis is given to the pedestal since, both the response to fire and the repair for such a massive structure are of particular interest.

  13. Principal facts for gravity stations of the Broadwater geothermal area, Montana

    SciTech Connect (OSTI)

    Bankey, V.; Paton, J.; Kleinkopf, M.D.

    1981-01-01T23:59:59.000Z

    Two complete Bouguer anomaly values were calculated for each of the 67 stations assuming average rock densities of 2.67 g/cm/sup 3/ and 2.45 g/cm/sup 3/. The corrections and anomaly values are listed. A hand contoured Bouguer gravity map is included.

  14. RACHEL J. BEANE Department of Geology 6800 College Station Bowdoin College Brunswick, Maine 04011-8468

    E-Print Network [OSTI]

    Beane, Rachel J.

    RACHEL J. BEANE Department of Geology · 6800 College Station · Bowdoin College · Brunswick, Maine PUBLICATIONS (* denotes undergraduate student author) Grew, E.S., Yates, M.G., Beane, R.J., Floss, C. and Gerbi, H.J., Price, N.A., Marsh, J.H., Koons, P.O., West, D.P., and Beane, R.J., accepted. Clast

  15. Modeling and Control of Flexible HEV Charging Station upgraded with Flywheel Energy Storage

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    1 Modeling and Control of Flexible HEV Charging Station upgraded with Flywheel Energy Storage. Flywheel has been selected as the means of storing energy as it provides high power density and does the energy stored in flywheel to compensate for the peak of power introduced by HEV charger, avoiding big

  16. U.S.DOE Global Monthly Station Temperature and Precipitation, 1738-1980

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    The global monthly station temperature and precipitation data from the U.S. Department of Energy, a dataset hosted at, covers the time period from January, 1738 to December, 1980. The air temperature and precipitation levels are platform observations from ground and water surfaces. The data are maintained in the Research Data Archive at the National Center for Atmospheric Research.

  17. Analysis of the Behavior of Electric Vehicle Charging Stations with Renewable Generations

    E-Print Network [OSTI]

    Wong, Vincent

    initial policy. Simulation results confirm the convergence of the game between EVCSs. The results also assumed that EVs are charged only at home. However, considering that conventional internal combustion engine vehicles refuel at gas stations, EVs might also be charged at other facilities which provide

  18. EIS-0080: Decommissioning of the Shippingport Atomic Power Station, Hanford Site, Richland, Washington

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy's Remedial Actions Program Office developed this statement to assess the impacts of decommissioning the Shippingport Atomic Power Station as well as analyze possible decommissioning alternatives, evaluate potential environmental impacts associated with each alternative, and present cost estimates for each alternative.

  19. All Metal Iron Core For A Low Aspect Ratio Tokamak

    SciTech Connect (OSTI)

    D.A. Gates, C. Jun, I. Zatz, A. Zolfaghari

    2010-06-02T23:59:59.000Z

    A novel concept for incorporating a iron core transformer within a axisymmetric toroidal plasma containment device with a high neutron flux is described. This design enables conceptual design of low aspect ratio devices which employ standard transformer-driven plasma startup by using all-metal high resistance separators between the toroidal field windings. This design avoids the inherent problems of a multiturn air core transformer which will inevitably suffer from strong neutron bombardment and hence lose the integrity of its insulation, both through long term material degradation and short term neutron- induced conductivity.. A full 3-dimensional model of the concept has been developed within the MAXWELL program and the resultant loop voltage calculated. The utility of the result is found to be dependent on the resistivity of the high resistance separators. Useful loop voltage time histories have been obtained using achievable resistivities.

  20. Modular low-aspect-ratio high-beta torsatron

    DOE Patents [OSTI]

    Sheffield, G.V.

    1982-04-01T23:59:59.000Z

    A fusion-reactor device is described which the toroidal magnetic field and at least a portion of the poloidal magnetic field are provided by a single set of modular coils. The coils are arranged on the surface of a low-aspect-ratio toroid in planed having the cylindrical coordinate relationship phi = phi/sub i/ + kz, where k is a constant equal to each coil's pitch and phi/sub i/ is the toroidal angle at which the i'th coil intersects the z = o plane. The toroid defined by the modular coils preferably has a race track minor cross section. When vertical field coils and, preferably, a toroidal plasma current are provided for magnetic-field-surface closure within the toroid, a vacuum magnetic field of racetrack-shaped minor cross section with improved stability and beta valves is obtained.