Powered by Deep Web Technologies
Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Proposals for Structural Biology Beamlines  

NLE Websites -- All DOE Office Websites (Extended Search)

Proposals for Structural Biology Beamlines Print Submit a New Proposal for Structural Biology Beamlines Available Beamlines The beamlines suitable for structural biology...

2

Proposals for Structural Biology Beamlines  

NLE Websites -- All DOE Office Websites (Extended Search)

Proposals for Structural Biology Beamlines Proposals for Structural Biology Beamlines Print Tuesday, 01 June 2010 09:52 Submit a New Proposal for Structural Biology Beamlines...

3

Beamlines  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamlines Beamlines Beamlines Print Beamlines Directory List of ALS beamlines, techniques, energy ranges, beamline scientists' contact information, and individual beamline schedules. The ALS Beamclock and links to the ALS Energy-Related Beamlines poster and beamclock are also available. Beam Status Current status of the ALS accelerator, updated every minute. Instructions on how to get beam status updates via Twitter @ALSRingStatus or text messages, and request form for beam history information. Research Techniques Research techniques and the corresponding beamlines where they are available (under construction). Schedules Weekly user schedule, current and upcoming long-term operating schedules; individual beamline long-term schedules can be found on the ALS Beamlines Directory.

4

Beamline 7.2  

NLE Websites -- All DOE Office Websites (Extended Search)

beamline GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range Port 1: 17 keV transmission though Mo...

5

Beamline 6.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print Ultrafast Femtosecond Dynamics Hard X Ray GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source...

6

Beamline 6.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print Ultrafast Femtosecond Dynamics Hard X Ray GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source...

7

Beamline 1.4.3  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamline 1.4.3 Print Beamline 1.4.3 Print FTIR spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.2 eV Frequency range 650 - 10,000 cm-1 Interferometer resolution Up to 0.125 cm-1 Endstations Nicolet Magna 760 FTIR, Nic-Plan IR Microscope (N2 purged) Characteristics Motorized sample stage, 0.1-micron resolution, reflection, transmission, and grazing-incidence reflection modes Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy Detectors MCT-A (mercury cadmium telluride) Spot size at sample

8

Beamline 1.4.3  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamline 1.4.3 Print Beamline 1.4.3 Print FTIR spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.2 eV Frequency range 650 - 10,000 cm-1 Interferometer resolution Up to 0.125 cm-1 Endstations Nicolet Magna 760 FTIR, Nic-Plan IR Microscope (N2 purged) Characteristics Motorized sample stage, 0.1-micron resolution, reflection, transmission, and grazing-incidence reflection modes Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy Detectors MCT-A (mercury cadmium telluride) Spot size at sample

9

Beamline 1.4.3  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamline 1.4.3 Print Beamline 1.4.3 Print FTIR spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.2 eV Frequency range 650 - 10,000 cm-1 Interferometer resolution Up to 0.125 cm-1 Endstations Nicolet Magna 760 FTIR, Nic-Plan IR Microscope (N2 purged) Characteristics Motorized sample stage, 0.1-micron resolution, reflection, transmission, and grazing-incidence reflection modes Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy Detectors MCT-A (mercury cadmium telluride) Spot size at sample

10

Beamline 12.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

2.3.1 2.3.1 Beamline 12.3.1 Print Tuesday, 20 October 2009 09:33 Structurally Integrated Biology for Life Sciences (SIBYLS) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend Energy range 5-17 keV (1% max flux) Frequency range 2.5-0.73 Angstrom wavelength Beam size 100 µm round beam default 10 µm and 30 µm collimators available for small samples with flux reduced to 1% and 12%, respectively. 120 µm x 120 µm Gaussian uncollimated beam shape at sample. Scientific discipline Structural biology Monochromator #1 Si(111) Double crystal Calculated flux (1.9 GeV, 400 mA) 2.5 x 1011 photons/sec at 11 keV Resolving power (E/ΔE) 7000

11

Beamline 5.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 3 Beamline 5.0.3 Print Tuesday, 20 October 2009 08:36 Berkeley Center for Structural Biology (BCSB) Monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm-period wiggler (W11) Energy range 12,700 eV(fixed) Monochromator Asymmetric cut single crystal Si(220) Measured flux 2.4 x 1011 photons/s at 400-mA ring current, with 1.5-mrad divergence and 100-µm pinhole collimator Divergence at sample 3.0 (h) x 0.4 (v) mrad (user selectable) Spot size 100 µm Endstations Standard hutch Detectors 3 x 3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available; automated sample mounting system

12

Beamline 12.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 1 Beamline 12.3.1 Print Tuesday, 20 October 2009 09:33 Structurally Integrated Biology for Life Sciences (SIBYLS) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend Energy range 5-17 keV (1% max flux) Frequency range 2.5-0.73 Angstrom wavelength Beam size 100 µm round beam default 10 µm and 30 µm collimators available for small samples with flux reduced to 1% and 12%, respectively. 120 µm x 120 µm Gaussian uncollimated beam shape at sample. Scientific discipline Structural biology Monochromator #1 Si(111) Double crystal Calculated flux (1.9 GeV, 400 mA) 2.5 x 1011 photons/sec at 11 keV Resolving power (E/ΔE) 7000 Monochromator #2

13

Beamline 5.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 1 Beamline 5.0.1 Print Tuesday, 20 October 2009 08:32 Berkeley Center for Structural Biology (BCSB) Monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm-period wiggler (W11) Energy range 12.7 keV (fixed) Monochromator Si(220) Asymmetric cut single crystal Measured flux 1.50 x 1011 photons/s at 400-mA ring current, with 1.5-mrad divergence and 100-µm pinhole collimator Resolving power (E/ΔE) ~10,000 Divergence at sample 3.0 (h) x 0.4 (v) mrad (user selectable) Spot size 100 µm Endstations Standard hutch Detectors 3 x 3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules

14

Beamline 12.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

3.1 3.1 Beamline 12.3.1 Print Tuesday, 20 October 2009 09:33 Structurally Integrated Biology for Life Sciences (SIBYLS) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend Energy range 5-17 keV (1% max flux) Frequency range 2.5-0.73 Angstrom wavelength Beam size 100 µm round beam default 10 µm and 30 µm collimators available for small samples with flux reduced to 1% and 12%, respectively. 120 µm x 120 µm Gaussian uncollimated beam shape at sample. Scientific discipline Structural biology Monochromator #1 Si(111) Double crystal Calculated flux (1.9 GeV, 400 mA) 2.5 x 1011 photons/sec at 11 keV Resolving power (E/ΔE) 7000

15

Beamline 5.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 3 Beamline 5.0.3 Print Tuesday, 20 October 2009 08:36 Berkeley Center for Structural Biology (BCSB) Monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm-period wiggler (W11) Energy range 12,700 eV(fixed) Monochromator Asymmetric cut single crystal Si(220) Measured flux 2.4 x 1011 photons/s at 400-mA ring current, with 1.5-mrad divergence and 100-µm pinhole collimator Divergence at sample 3.0 (h) x 0.4 (v) mrad (user selectable) Spot size 100 µm Endstations Standard hutch Detectors 3 x 3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available; automated sample mounting system

16

Beamline 3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

beamline GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 1-2 keV transmission through thin-film carbon...

17

Beamline 5.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

5.0.2 5.0.2 Beamline 5.0.2 Print Tuesday, 20 October 2009 08:35 Berkeley Center for Structural Biology (BCSB) Multiple-wavelength anomalous diffraction (MAD) and monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm period wiggler (W11) Energy range 5-16 keV Monochromator Double-crystal, Si(111) liquid N2 cooled Measured flux at 12.4 keV 8.0 x 1011 photons/s at 400-mA ring current, with 1.5-mrad convergence and 100-µm pinhole collimator Resolving power (E/ΔE) 7,000 Divergence at sample 3.0(h) x 0.4 (v) mrad (user selectable) Spot size 25-125 µm (user selectable) Endstations Standard hutch Characteristics

18

Photon Sciences | Navigation | Beamlines  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamlines NSLS Beamlines by Technique Beamlines by Number Facility Beamlines PRT Beamlines Beamline Consortia GU Proposal Scores Beamline Safety and Training Documents NSLS-II...

19

Beamline 6.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Beamline 6.0.1 Print Tuesday, 20 October 2009 08:38 Ultrafast Femtosecond Dynamics Hard X Ray GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General...

20

Beamline 5.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Berkeley Center for Structural Biology (BCSB) Monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm-period wiggler (W11) Energy range 12.7 keV (fixed) Monochromator Si(220) Asymmetric cut single crystal Measured flux 1.50 x 1011 photons/s at 400-mA ring current, with 1.5-mrad divergence and 100-µm pinhole collimator Resolving power (E/ΔE) ~10,000 Divergence at sample 3.0 (h) x 0.4 (v) mrad (user selectable) Spot size 100 µm Endstations Standard hutch Detectors 3 x 3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Beamline 12.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Structurally Integrated Biology for Life Sciences (SIBYLS) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend Energy range 5-17 keV (1% max flux) Frequency range 2.5-0.73 Angstrom wavelength Beam size 100 µm round beam default 10 µm and 30 µm collimators available for small samples with flux reduced to 1% and 12%, respectively. 120 µm x 120 µm Gaussian uncollimated beam shape at sample. Scientific discipline Structural biology Monochromator #1 Si(111) Double crystal Calculated flux (1.9 GeV, 400 mA) 2.5 x 1011 photons/sec at 11 keV Resolving power (E/ΔE) 7000 Monochromator #2 0.6% bandpass multilayers Calculated flux (1.9 GeV, 400 mA)

22

Beamline 12.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Structurally Integrated Biology for Life Sciences (SIBYLS) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend Energy range 5-17 keV (1% max flux) Frequency range 2.5-0.73 Angstrom wavelength Beam size 100 µm round beam default 10 µm and 30 µm collimators available for small samples with flux reduced to 1% and 12%, respectively. 120 µm x 120 µm Gaussian uncollimated beam shape at sample. Scientific discipline Structural biology Monochromator #1 Si(111) Double crystal Calculated flux (1.9 GeV, 400 mA) 2.5 x 1011 photons/sec at 11 keV Resolving power (E/ΔE) 7000 Monochromator #2 0.6% bandpass multilayers Calculated flux (1.9 GeV, 400 mA)

23

Beamline 5.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print Berkeley Center for Structural Biology (BCSB) Monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm-period wiggler (W11) Energy range 12,700 eV(fixed) Monochromator Asymmetric cut single crystal Si(220) Measured flux 2.4 x 1011 photons/s at 400-mA ring current, with 1.5-mrad divergence and 100-µm pinhole collimator Divergence at sample 3.0 (h) x 0.4 (v) mrad (user selectable) Spot size 100 µm Endstations Standard hutch Detectors 3 x 3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available; automated sample mounting system

24

Beamline 8.2.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Berkeley Center for Structural Biology (BCSB) Multiple-Wavelength Anomalous Diffraction (MAD) and Macromolecular Crystallography (MX) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend magnet (5.0 T, single pole) Energy range 5-16 keV Monochromator Double crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 3.0 x 1011 photons/sec Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0 (h) x 0.5 (v) mrad Measured spot size (FWHM) 100 µm Endstations Minihutch Detectors 3x3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available Sample environment Ambient or ~100 K

25

Beamline 12.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

12.3.1 Print 12.3.1 Print Structurally Integrated Biology for Life Sciences (SIBYLS) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend Energy range 5-17 keV (1% max flux) Frequency range 2.5-0.73 Angstrom wavelength Beam size 100 µm round beam default 10 µm and 30 µm collimators available for small samples with flux reduced to 1% and 12%, respectively. 120 µm x 120 µm Gaussian uncollimated beam shape at sample. Scientific discipline Structural biology Monochromator #1 Si(111) Double crystal Calculated flux (1.9 GeV, 400 mA) 2.5 x 1011 photons/sec at 11 keV Resolving power (E/ΔE) 7000 Monochromator #2 0.6% bandpass multilayers Calculated flux (1.9 GeV, 400 mA)

26

Beamline 12.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Structurally Integrated Biology for Life Sciences (SIBYLS) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend Energy range 5-17 keV (1% max flux) Frequency range 2.5-0.73 Angstrom wavelength Beam size 100 µm round beam default 10 µm and 30 µm collimators available for small samples with flux reduced to 1% and 12%, respectively. 120 µm x 120 µm Gaussian uncollimated beam shape at sample. Scientific discipline Structural biology Monochromator #1 Si(111) Double crystal Calculated flux (1.9 GeV, 400 mA) 2.5 x 1011 photons/sec at 11 keV Resolving power (E/ΔE) 7000 Monochromator #2 0.6% bandpass multilayers Calculated flux (1.9 GeV, 400 mA)

27

Beamline 5.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Berkeley Center for Structural Biology (BCSB) Monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm-period wiggler (W11) Energy range 12.7 keV (fixed) Monochromator Si(220) Asymmetric cut single crystal Measured flux 1.50 x 1011 photons/s at 400-mA ring current, with 1.5-mrad divergence and 100-µm pinhole collimator Resolving power (E/ΔE) ~10,000 Divergence at sample 3.0 (h) x 0.4 (v) mrad (user selectable) Spot size 100 µm Endstations Standard hutch Detectors 3 x 3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available

28

Beamline 8.2.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Berkeley Center for Structural Biology (BCSB) Multiple-Wavelength Anomalous Diffraction (MAD) and Macromolecular Crystallography (MX) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend magnet (5.0 T, single pole) Energy range 5-16 keV Monochromator Double crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 3.0 x 1011 photons/sec Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0 (h) x 0.5 (v) mrad Measured spot size (FWHM) 100 µm Endstations Minihutch Detectors 3x3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available Sample environment Ambient or ~100 K

29

Beamline 5.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print Berkeley Center for Structural Biology (BCSB) Monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm-period wiggler (W11) Energy range 12,700 eV(fixed) Monochromator Asymmetric cut single crystal Si(220) Measured flux 2.4 x 1011 photons/s at 400-mA ring current, with 1.5-mrad divergence and 100-µm pinhole collimator Divergence at sample 3.0 (h) x 0.4 (v) mrad (user selectable) Spot size 100 µm Endstations Standard hutch Detectors 3 x 3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available; automated sample mounting system

30

Beamline 5.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print Berkeley Center for Structural Biology (BCSB) Monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm-period wiggler (W11) Energy range 12,700 eV(fixed) Monochromator Asymmetric cut single crystal Si(220) Measured flux 2.4 x 1011 photons/s at 400-mA ring current, with 1.5-mrad divergence and 100-µm pinhole collimator Divergence at sample 3.0 (h) x 0.4 (v) mrad (user selectable) Spot size 100 µm Endstations Standard hutch Detectors 3 x 3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available; automated sample mounting system

31

Beamline 5.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print Berkeley Center for Structural Biology (BCSB) Monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm-period wiggler (W11) Energy range 12,700 eV(fixed) Monochromator Asymmetric cut single crystal Si(220) Measured flux 2.4 x 1011 photons/s at 400-mA ring current, with 1.5-mrad divergence and 100-µm pinhole collimator Divergence at sample 3.0 (h) x 0.4 (v) mrad (user selectable) Spot size 100 µm Endstations Standard hutch Detectors 3 x 3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available; automated sample mounting system

32

Beamline 5.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Berkeley Center for Structural Biology (BCSB) Monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm-period wiggler (W11) Energy range 12.7 keV (fixed) Monochromator Si(220) Asymmetric cut single crystal Measured flux 1.50 x 1011 photons/s at 400-mA ring current, with 1.5-mrad divergence and 100-µm pinhole collimator Resolving power (E/ΔE) ~10,000 Divergence at sample 3.0 (h) x 0.4 (v) mrad (user selectable) Spot size 100 µm Endstations Standard hutch Detectors 3 x 3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available

33

Beamline 5.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Berkeley Center for Structural Biology (BCSB) Monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm-period wiggler (W11) Energy range 12.7 keV (fixed) Monochromator Si(220) Asymmetric cut single crystal Measured flux 1.50 x 1011 photons/s at 400-mA ring current, with 1.5-mrad divergence and 100-µm pinhole collimator Resolving power (E/ΔE) ~10,000 Divergence at sample 3.0 (h) x 0.4 (v) mrad (user selectable) Spot size 100 µm Endstations Standard hutch Detectors 3 x 3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available

34

Beamline 8.2.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Berkeley Center for Structural Biology (BCSB) Multiple-Wavelength Anomalous Diffraction (MAD) and Macromolecular Crystallography (MX) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend magnet (5.0 T, single pole) Energy range 5-16 keV Monochromator Double crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 3.0 x 1011 photons/sec Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0 (h) x 0.5 (v) mrad Measured spot size (FWHM) 100 µm Endstations Minihutch Detectors 3x3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available Sample environment Ambient or ~100 K

35

Beamline 5.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Berkeley Center for Structural Biology (BCSB) Monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm-period wiggler (W11) Energy range 12.7 keV (fixed) Monochromator Si(220) Asymmetric cut single crystal Measured flux 1.50 x 1011 photons/s at 400-mA ring current, with 1.5-mrad divergence and 100-µm pinhole collimator Resolving power (E/ΔE) ~10,000 Divergence at sample 3.0 (h) x 0.4 (v) mrad (user selectable) Spot size 100 µm Endstations Standard hutch Detectors 3 x 3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available

36

Beamline 5.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print Berkeley Center for Structural Biology (BCSB) Monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm-period wiggler (W11) Energy range 12,700 eV(fixed) Monochromator Asymmetric cut single crystal Si(220) Measured flux 2.4 x 1011 photons/s at 400-mA ring current, with 1.5-mrad divergence and 100-µm pinhole collimator Divergence at sample 3.0 (h) x 0.4 (v) mrad (user selectable) Spot size 100 µm Endstations Standard hutch Detectors 3 x 3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available; automated sample mounting system

37

Beamline 8.2.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Berkeley Center for Structural Biology (BCSB) Multiple-Wavelength Anomalous Diffraction (MAD) and Macromolecular Crystallography (MX) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend magnet (5.0 T, single pole) Energy range 5-16 keV Monochromator Double crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 3.0 x 1011 photons/sec Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0 (h) x 0.5 (v) mrad Measured spot size (FWHM) 100 µm Endstations Minihutch Detectors 3x3 CCD array (ADSC Q315R) Sample format Single crystals of biological molecules Sample preparation Support labs available Sample environment Ambient or ~100 K

38

Beamline 8.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Berkeley Center for Structural Biology (BCSB) Multiple-Wavelength Anomalous Diffraction (MAD) and Macromolecular Crystallography (MX) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend (5.0 T, single pole) Energy range 5-16 keV Monochromator Double crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 3.0 x 1011 photons/sec Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0(h) x 0.5(v) mrad Measured spot size at sample (FWHM) 100 µm Endstations Minihutch Detectors 3x3 CCD array (ADSC Q315) Sample format Single crystals of biological molecules Sample preparation Support labs available Sample environment Ambient or ~100 K Special notes Computers for data processing and analysis are available

39

Beamline 8.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Berkeley Center for Structural Biology (BCSB) Multiple-Wavelength Anomalous Diffraction (MAD) and Macromolecular Crystallography (MX) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend (5.0 T, single pole) Energy range 5-16 keV Monochromator Double crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 3.0 x 1011 photons/sec Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0(h) x 0.5(v) mrad Measured spot size at sample (FWHM) 100 µm Endstations Minihutch Detectors 3x3 CCD array (ADSC Q315) Sample format Single crystals of biological molecules Sample preparation Support labs available Sample environment Ambient or ~100 K Special notes Computers for data processing and analysis are available

40

Beamline 5.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Berkeley Center for Structural Biology (BCSB) Multiple-wavelength anomalous diffraction (MAD) and monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm period wiggler (W11) Energy range 5-16 keV Monochromator Double-crystal, Si(111) liquid N2 cooled Measured flux at 12.4 keV 8.0 x 1011 photons/s at 400-mA ring current, with 1.5-mrad convergence and 100-µm pinhole collimator Resolving power (E/ΔE) 7,000 Divergence at sample 3.0(h) x 0.4 (v) mrad (user selectable) Spot size 25-125 µm (user selectable) Endstations Standard hutch Characteristics Single axis, air bearing goniometer; CCD detector, low-temperature system

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Beamline 8.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

3.1 Print 3.1 Print Multiple-wavelength anomalous diffraction (MAD) and macromolecular crystallography (MX) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend magnet (5.0 tesla, single pole) Energy range 5-17 keV (1% max flux) Monochromator Double flat crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 2.5 x 1011 at 11 keV Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0 (h) x 0.35 (v) mrad Endstations Minihutch Detectors 3 x 3 CCD array (ADSC Q315r) Measured spot size at sample (FWHM) 0.120 (h) x 0.108 (v) mm Sample format Single crystals of biological molecules. Crystallization tray goniometer available with prior arrangement.

42

Beamline 5.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Berkeley Center for Structural Biology (BCSB) Multiple-wavelength anomalous diffraction (MAD) and monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm period wiggler (W11) Energy range 5-16 keV Monochromator Double-crystal, Si(111) liquid N2 cooled Measured flux at 12.4 keV 8.0 x 1011 photons/s at 400-mA ring current, with 1.5-mrad convergence and 100-µm pinhole collimator Resolving power (E/ΔE) 7,000 Divergence at sample 3.0(h) x 0.4 (v) mrad (user selectable) Spot size 25-125 µm (user selectable) Endstations Standard hutch Characteristics Single axis, air bearing goniometer; CCD detector, low-temperature system

43

Beamline 8.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Berkeley Center for Structural Biology (BCSB) Multiple-Wavelength Anomalous Diffraction (MAD) and Macromolecular Crystallography (MX) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend (5.0 T, single pole) Energy range 5-16 keV Monochromator Double crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 3.0 x 1011 photons/sec Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0(h) x 0.5(v) mrad Measured spot size at sample (FWHM) 100 µm Endstations Minihutch Detectors 3x3 CCD array (ADSC Q315) Sample format Single crystals of biological molecules Sample preparation Support labs available Sample environment Ambient or ~100 K Special notes Computers for data processing and analysis are available

44

Beamline 5.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Berkeley Center for Structural Biology (BCSB) Multiple-wavelength anomalous diffraction (MAD) and monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm period wiggler (W11) Energy range 5-16 keV Monochromator Double-crystal, Si(111) liquid N2 cooled Measured flux at 12.4 keV 8.0 x 1011 photons/s at 400-mA ring current, with 1.5-mrad convergence and 100-µm pinhole collimator Resolving power (E/ΔE) 7,000 Divergence at sample 3.0(h) x 0.4 (v) mrad (user selectable) Spot size 25-125 µm (user selectable) Endstations Standard hutch Characteristics Single axis, air bearing goniometer; CCD detector, low-temperature system

45

Beamline 5.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Berkeley Center for Structural Biology (BCSB) Multiple-wavelength anomalous diffraction (MAD) and monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm period wiggler (W11) Energy range 5-16 keV Monochromator Double-crystal, Si(111) liquid N2 cooled Measured flux at 12.4 keV 8.0 x 1011 photons/s at 400-mA ring current, with 1.5-mrad convergence and 100-µm pinhole collimator Resolving power (E/ΔE) 7,000 Divergence at sample 3.0(h) x 0.4 (v) mrad (user selectable) Spot size 25-125 µm (user selectable) Endstations Standard hutch Characteristics Single axis, air bearing goniometer; CCD detector, low-temperature system

46

Beamline 8.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Berkeley Center for Structural Biology (BCSB) Multiple-Wavelength Anomalous Diffraction (MAD) and Macromolecular Crystallography (MX) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend (5.0 T, single pole) Energy range 5-16 keV Monochromator Double crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 3.0 x 1011 photons/sec Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0(h) x 0.5(v) mrad Measured spot size at sample (FWHM) 100 µm Endstations Minihutch Detectors 3x3 CCD array (ADSC Q315) Sample format Single crystals of biological molecules Sample preparation Support labs available Sample environment Ambient or ~100 K Special notes Computers for data processing and analysis are available

47

Beamline 8.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Berkeley Center for Structural Biology (BCSB) Multiple-Wavelength Anomalous Diffraction (MAD) and Macromolecular Crystallography (MX) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend (5.0 T, single pole) Energy range 5-16 keV Monochromator Double crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 3.0 x 1011 photons/sec Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0(h) x 0.5(v) mrad Measured spot size at sample (FWHM) 100 µm Endstations Minihutch Detectors 3x3 CCD array (ADSC Q315) Sample format Single crystals of biological molecules Sample preparation Support labs available Sample environment Ambient or ~100 K Special notes Computers for data processing and analysis are available

48

Beamline 8.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Berkeley Center for Structural Biology (BCSB) Multiple-Wavelength Anomalous Diffraction (MAD) and Macromolecular Crystallography (MX) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend (5.0 T, single pole) Energy range 5-16 keV Monochromator Double crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 3.0 x 1011 photons/sec Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0(h) x 0.5(v) mrad Measured spot size at sample (FWHM) 100 µm Endstations Minihutch Detectors 3x3 CCD array (ADSC Q315) Sample format Single crystals of biological molecules Sample preparation Support labs available Sample environment Ambient or ~100 K Special notes Computers for data processing and analysis are available

49

Beamline 8.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Multiple-wavelength anomalous diffraction (MAD) and macromolecular crystallography (MX) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend magnet (5.0 tesla, single pole) Energy range 5-17 keV (1% max flux) Monochromator Double flat crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 2.5 x 1011 at 11 keV Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0 (h) x 0.35 (v) mrad Endstations Minihutch Detectors 3 x 3 CCD array (ADSC Q315r) Measured spot size at sample (FWHM) 0.120 (h) x 0.108 (v) mm Sample format Single crystals of biological molecules. Crystallization tray goniometer available with prior arrangement.

50

Beamline 8.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Berkeley Center for Structural Biology (BCSB) Multiple-Wavelength Anomalous Diffraction (MAD) and Macromolecular Crystallography (MX) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend (5.0 T, single pole) Energy range 5-16 keV Monochromator Double crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 3.0 x 1011 photons/sec Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0(h) x 0.5(v) mrad Measured spot size at sample (FWHM) 100 µm Endstations Minihutch Detectors 3x3 CCD array (ADSC Q315) Sample format Single crystals of biological molecules Sample preparation Support labs available Sample environment Ambient or ~100 K Special notes Computers for data processing and analysis are available

51

Beamline 8.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Multiple-wavelength anomalous diffraction (MAD) and macromolecular crystallography (MX) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend magnet (5.0 tesla, single pole) Energy range 5-17 keV (1% max flux) Monochromator Double flat crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 2.5 x 1011 at 11 keV Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0 (h) x 0.35 (v) mrad Endstations Minihutch Detectors 3 x 3 CCD array (ADSC Q315r) Measured spot size at sample (FWHM) 0.120 (h) x 0.108 (v) mm Sample format Single crystals of biological molecules. Crystallization tray goniometer available with prior arrangement.

52

Beamline 8.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Berkeley Center for Structural Biology (BCSB) Multiple-Wavelength Anomalous Diffraction (MAD) and Macromolecular Crystallography (MX) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend (5.0 T, single pole) Energy range 5-16 keV Monochromator Double crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 3.0 x 1011 photons/sec Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0(h) x 0.5(v) mrad Measured spot size at sample (FWHM) 100 µm Endstations Minihutch Detectors 3x3 CCD array (ADSC Q315) Sample format Single crystals of biological molecules Sample preparation Support labs available Sample environment Ambient or ~100 K Special notes Computers for data processing and analysis are available

53

Beamline 8.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Multiple-wavelength anomalous diffraction (MAD) and macromolecular crystallography (MX) Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend magnet (5.0 tesla, single pole) Energy range 5-17 keV (1% max flux) Monochromator Double flat crystal, Si(111) Measured flux (1.9 GeV, 400 mA) 2.5 x 1011 at 11 keV Resolving power (E/ΔE) 7,000 Divergence (max at sample) 3.0 (h) x 0.35 (v) mrad Endstations Minihutch Detectors 3 x 3 CCD array (ADSC Q315r) Measured spot size at sample (FWHM) 0.120 (h) x 0.108 (v) mm Sample format Single crystals of biological molecules. Crystallization tray goniometer available with prior arrangement.

54

Beamline 5.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Berkeley Center for Structural Biology (BCSB) Multiple-wavelength anomalous diffraction (MAD) and monochromatic protein crystallography Scientific discipline: Structural biology GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics 11.4-cm period wiggler (W11) Energy range 5-16 keV Monochromator Double-crystal, Si(111) liquid N2 cooled Measured flux at 12.4 keV 8.0 x 1011 photons/s at 400-mA ring current, with 1.5-mrad convergence and 100-µm pinhole collimator Resolving power (E/ΔE) 7,000 Divergence at sample 3.0(h) x 0.4 (v) mrad (user selectable) Spot size 25-125 µm (user selectable) Endstations Standard hutch Characteristics Single axis, air bearing goniometer; CCD detector, low-temperature system

55

Beamlines Map | Advanced Photon Source  

NLE Websites -- All DOE Office Websites (Extended Search)

Map For a table view of basic technical capabilities of a particular beamline go to the APS Beamline Directory. Note that only BMs and IDs available for the general user program...

56

Beamline 1.4.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print FTIR spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.2 eV Frequency range 650 - 10,000 cm-1 Interferometer resolution Up to 0.125 cm-1 Endstations Nicolet Magna 760 FTIR, Nic-Plan IR Microscope (N2 purged) Characteristics Motorized sample stage, 0.1-micron resolution, reflection, transmission, and grazing-incidence reflection modes Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy Detectors MCT-A (mercury cadmium telluride) Spot size at sample 2-10 µm (diffraction-limited)

57

Beamline 1.4.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print FTIR spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.2 eV Frequency range 650 - 10,000 cm-1 Interferometer resolution Up to 0.125 cm-1 Endstations Nicolet Magna 760 FTIR, Nic-Plan IR Microscope (N2 purged) Characteristics Motorized sample stage, 0.1-micron resolution, reflection, transmission, and grazing-incidence reflection modes Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy Detectors MCT-A (mercury cadmium telluride) Spot size at sample 2-10 µm (diffraction-limited)

58

Beamline 1.4.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print FTIR spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.2 eV Frequency range 650 - 10,000 cm-1 Interferometer resolution Up to 0.125 cm-1 Endstations Nicolet Magna 760 FTIR, Nic-Plan IR Microscope (N2 purged) Characteristics Motorized sample stage, 0.1-micron resolution, reflection, transmission, and grazing-incidence reflection modes Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy Detectors MCT-A (mercury cadmium telluride) Spot size at sample 2-10 µm (diffraction-limited)

59

Beamline 1.4.3  

NLE Websites -- All DOE Office Websites (Extended Search)

1.4.3 Print 1.4.3 Print FTIR spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.2 eV Frequency range 650 - 10,000 cm-1 Interferometer resolution Up to 0.125 cm-1 Endstations Nicolet Magna 760 FTIR, Nic-Plan IR Microscope (N2 purged) Characteristics Motorized sample stage, 0.1-micron resolution, reflection, transmission, and grazing-incidence reflection modes Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy Detectors MCT-A (mercury cadmium telluride) Spot size at sample

60

Beamline 1.4.4  

NLE Websites -- All DOE Office Websites (Extended Search)

4 Print 4 Print Infrared spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.5 eV Frequency range 800 - 10,000 cm-1 Interferometer resolution up to 0.125 cm-1 Endstations Thermo Nicolet Nexus 870 FTIR, Continuum XL IR microscope (N2 purged) Characteristics Computerized sample stage, 0.1-micron resolution; reflection, transmission, and attenuated total reflectance (ATR) modes; differential interference contrast (DIC), polarizing and UV fluorescence optics Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Beamline 1.4.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print FTIR spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.2 eV Frequency range 650 - 10,000 cm-1 Interferometer resolution Up to 0.125 cm-1 Endstations Nicolet Magna 760 FTIR, Nic-Plan IR Microscope (N2 purged) Characteristics Motorized sample stage, 0.1-micron resolution, reflection, transmission, and grazing-incidence reflection modes Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy Detectors MCT-A (mercury cadmium telluride) Spot size at sample 2-10 µm (diffraction-limited)

62

Beamline 1.4.4  

NLE Websites -- All DOE Office Websites (Extended Search)

4 Print 4 Print Infrared spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.5 eV Frequency range 800 - 10,000 cm-1 Interferometer resolution up to 0.125 cm-1 Endstations Thermo Nicolet Nexus 870 FTIR, Continuum XL IR microscope (N2 purged) Characteristics Computerized sample stage, 0.1-micron resolution; reflection, transmission, and attenuated total reflectance (ATR) modes; differential interference contrast (DIC), polarizing and UV fluorescence optics Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy

63

Beamline 1.4.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print FTIR spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.2 eV Frequency range 650 - 10,000 cm-1 Interferometer resolution Up to 0.125 cm-1 Endstations Nicolet Magna 760 FTIR, Nic-Plan IR Microscope (N2 purged) Characteristics Motorized sample stage, 0.1-micron resolution, reflection, transmission, and grazing-incidence reflection modes Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy Detectors MCT-A (mercury cadmium telluride) Spot size at sample 2-10 µm (diffraction-limited)

64

Beamline 1.4.3  

NLE Websites -- All DOE Office Websites (Extended Search)

1.4.3 Print 1.4.3 Print FTIR spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.2 eV Frequency range 650 - 10,000 cm-1 Interferometer resolution Up to 0.125 cm-1 Endstations Nicolet Magna 760 FTIR, Nic-Plan IR Microscope (N2 purged) Characteristics Motorized sample stage, 0.1-micron resolution, reflection, transmission, and grazing-incidence reflection modes Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy Detectors MCT-A (mercury cadmium telluride) Spot size at sample

65

Beamline 1.4.3  

NLE Websites -- All DOE Office Websites (Extended Search)

1.4.3 Print 1.4.3 Print FTIR spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.2 eV Frequency range 650 - 10,000 cm-1 Interferometer resolution Up to 0.125 cm-1 Endstations Nicolet Magna 760 FTIR, Nic-Plan IR Microscope (N2 purged) Characteristics Motorized sample stage, 0.1-micron resolution, reflection, transmission, and grazing-incidence reflection modes Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy Detectors MCT-A (mercury cadmium telluride) Spot size at sample

66

Beamline 1.4.4  

NLE Websites -- All DOE Office Websites (Extended Search)

4 Print 4 Print Infrared spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.5 eV Frequency range 800 - 10,000 cm-1 Interferometer resolution up to 0.125 cm-1 Endstations Thermo Nicolet Nexus 870 FTIR, Continuum XL IR microscope (N2 purged) Characteristics Computerized sample stage, 0.1-micron resolution; reflection, transmission, and attenuated total reflectance (ATR) modes; differential interference contrast (DIC), polarizing and UV fluorescence optics Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy

67

Beamline 1.4.3  

NLE Websites -- All DOE Office Websites (Extended Search)

1.4.3 Print 1.4.3 Print FTIR spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.2 eV Frequency range 650 - 10,000 cm-1 Interferometer resolution Up to 0.125 cm-1 Endstations Nicolet Magna 760 FTIR, Nic-Plan IR Microscope (N2 purged) Characteristics Motorized sample stage, 0.1-micron resolution, reflection, transmission, and grazing-incidence reflection modes Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy Detectors MCT-A (mercury cadmium telluride) Spot size at sample

68

Beamline 1.4.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print FTIR spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.2 eV Frequency range 650 - 10,000 cm-1 Interferometer resolution Up to 0.125 cm-1 Endstations Nicolet Magna 760 FTIR, Nic-Plan IR Microscope (N2 purged) Characteristics Motorized sample stage, 0.1-micron resolution, reflection, transmission, and grazing-incidence reflection modes Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy Detectors MCT-A (mercury cadmium telluride) Spot size at sample 2-10 µm (diffraction-limited)

69

Beamline 1.4.4  

NLE Websites -- All DOE Office Websites (Extended Search)

4 Print 4 Print Infrared spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 0.05-1.5 eV Frequency range 800 - 10,000 cm-1 Interferometer resolution up to 0.125 cm-1 Endstations Thermo Nicolet Nexus 870 FTIR, Continuum XL IR microscope (N2 purged) Characteristics Computerized sample stage, 0.1-micron resolution; reflection, transmission, and attenuated total reflectance (ATR) modes; differential interference contrast (DIC), polarizing and UV fluorescence optics Spatial resolution Diffraction-limited (~wavelength); x-y stage with 0.1 micron accuracy

70

Beamline 5.4.1  

NLE Websites -- All DOE Office Websites (Extended Search)

5.4.1 5.4.1 Beamline 5.4.1 Print Infrared spectromicroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics Bend magnet Energy range 0.07-1.25 eV Frequency range 600 - 10,000 cm-1 Interferometer resolution 0.125 cm-1 Endstations FTIR bench and IR microscope (N2 purged) Characteristics Computerized sample stage, 0.1-micron resolution; reflection, transmission, and attenuated total reflectance (ATR) modes; polarizing and UV fluorescence optics Spatial resolution Diffraction limited (~wavelength) Detectors Probably MCT-A*, MCT-B (mercury cadmium telluride) Spot size at sample 2-10 µm (diffraction-limited) Sample preparation Biological preparation equipment available including incubator, biohoods, prep table, and more TBD. Sample environment N2 purged, minimal clean area (no particle specification), microcryostat/heater stages available for 4.2-730 K

71

Beamline 6.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

Now Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 300-2000 eV Monochromator VLS-PGM...

72

Beamline 4.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

Operational Yes Proposal cycle Proposals for Structural Biology Beamlines (2-month cycle) Source characteristics Superbend Energy range 5,500-16,000eV Monochromator Rosenbaum-Rock...

73

Beamline 12.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamline 12.2.2 Beamline 12.2.2 Beamline 12.2.2 Print Tuesday, 20 October 2009 09:31 High-Pressure (California High-Pressure Science Observatory: Calipso) Endstations: Medium pressure High pressure laser heating GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Superbend magnet, 1.9GeV, 5.29Tesla, 500mA Monochromator Si(111) or Multilayer Energy range 6-40 keV for Si(111), 14-28 keV for Multilayer Resolving power (E/ΔE) Si(111) = 7000, Multilayer =100 Beam size (HxV) Focused: 10 x 10 micron Unfocused: 90 x 100 micron Scientific applications High-pressure science Scientific disciplines Earth sciences, materials science, construction materials, chemistry, energy. Endstations Medium pressure

74

Photon Sciences Directorate | 2010 Annual Report | FY10 Beamline Guide  

NLE Websites -- All DOE Office Websites (Extended Search)

FY10 Beamline Guide FY10 Beamline Guide beamline status chart Click on the image to download a high-resolution version. Beamline Status In 2010, 49 X-Ray and 11 Vacuum Ultraviolet-Infrared operational beamlines were available for a wide range of experiments using a variety of techniques. There are two types of beamlines at NSLS: facility beamlines, of which there were 21; and participating research team (PRT) beamlines, of which there were 39. Facility beamlines are operated by Photon Sciences staff members and reserve a minimum of 50 percent of their beam time for general users. PRT beamlines are run by user groups with similar interests and reserve 25 percent of their beam time for general users, although they can grant additional time at their own discretion. The following pages provide details on NSLS operational beamlines,

75

APS Preliminary Beamline Design Report Guide  

NLE Websites -- All DOE Office Websites (Extended Search)

PRELIMINARY BEAMLINE DESIGN REPORT PRELIMINARY BEAMLINE DESIGN REPORT December 5, 1994 5.1 Preliminary Beamline Design: General Guidelines The Preliminary Design of the beamline represents an approximately 30% design level of each of the beamline components. This level of design permits the CAT to develop cost estimates for the construction of the beamline, as well as a realistic timeline for completion of the construction tasks. A committee from the APS has been charged with reviewing the Preliminary Design Reports and has established the evaluation criteria described below. The Preliminary Beamline Report is expected to expand upon the Conceptual Design Report in the following areas: Beamline Layout Component Design Work Breakdown Structure Cost and Schedule Additional Operational Requirements

76

Beamline 11.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

Magnetism, materials, surface science, polymers Endstations: 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering GENERAL BEAMLINE INFORMATION...

77

Beamline 12.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Superbend magnet, 1.9GeV, 5.29Tesla, 500mA Monochromator Si(111) or...

78

Beamline 6.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 3-cm period undulator (U3) Energy range 2.3-9 keV Monochromator Double...

79

ALS Beamlines Directory  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamlines Directory Beamlines Directory ALS Beamlines Directory Print Beamlines, Parameters, Contact Information, and Schedules Download a high-resolution version of the ALS Beamclock. See Beamclock to view the ALS energy-related beamlines beamclock. Beamline Parameters Beamline and endstation technical information is available through the links below. Unless otherwise noted, all beamlines are currently operational. Individual beamline schedules are posted when available. Please contact the responsible beamline scientist for additional schedule information. When calling from off-site, all beamline (BL) phone numbers that begin with a "2" are preceded by 495- (i.e., 495-2014); all others are preceded by 486-. Beamline Number Source Technique/ Group Name Energy Range Beamline Contact Schedule/BL Phone

80

BNL | ATF Beamline Descriptions  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamline Simulation Data and Control Panel Displays Beamline Simulation Data and Control Panel Displays Beamline 0 Beamline 1 Beamline 2 Beamline 0 is directly downstream of the linac and serves to transport the beam from the linac to any one of the three experimental beamlines. Beamline 0 is modeled using MAD. Shown below is a summary of the MAD simulation results. Beamline control system panel (PDF) Transport line control system panel (PDF) MAD input deck Raw output beamline 0 This beam line currently serves the Plasma Acceleration, Current Filamentation Instability and Compton scattering experiments. A summary of the MAD simulation results is shown below. MAD input deck | Output of optical functions | Beamline control system panel (PDF) beamline 1 output ATF beamline 2 previously served the IFEL experiment, the SASE experiment

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Beamline 5.4.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Infrared spectromicroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics Bend magnet Energy range 0.07-1.25 eV Frequency range 600 - 10,000 cm-1 Interferometer resolution 0.125 cm-1 Endstations FTIR bench and IR microscope (N2 purged) Characteristics Computerized sample stage, 0.1-micron resolution; reflection, transmission, and attenuated total reflectance (ATR) modes; polarizing and UV fluorescence optics Spatial resolution Diffraction limited (~wavelength) Detectors Probably MCT-A*, MCT-B (mercury cadmium telluride) Spot size at sample 2-10 µm (diffraction-limited) Sample preparation Biological preparation equipment available including incubator, biohoods, prep table, and more TBD. Sample environment N2 purged, minimal clean area (no particle specification), microcryostat/heater stages available for 4.2-730 K

82

Beamline 5.4.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Infrared spectromicroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics Bend magnet Energy range 0.07-1.25 eV Frequency range 600 - 10,000 cm-1 Interferometer resolution 0.125 cm-1 Endstations FTIR bench and IR microscope (N2 purged) Characteristics Computerized sample stage, 0.1-micron resolution; reflection, transmission, and attenuated total reflectance (ATR) modes; polarizing and UV fluorescence optics Spatial resolution Diffraction limited (~wavelength) Detectors Probably MCT-A*, MCT-B (mercury cadmium telluride) Spot size at sample 2-10 µm (diffraction-limited) Sample preparation Biological preparation equipment available including incubator, biohoods, prep table, and more TBD. Sample environment N2 purged, minimal clean area (no particle specification), microcryostat/heater stages available for 4.2-730 K

83

Beamline 5.4.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Infrared spectromicroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics Bend magnet Energy range 0.07-1.25 eV Frequency range 600 - 10,000 cm-1 Interferometer resolution 0.125 cm-1 Endstations FTIR bench and IR microscope (N2 purged) Characteristics Computerized sample stage, 0.1-micron resolution; reflection, transmission, and attenuated total reflectance (ATR) modes; polarizing and UV fluorescence optics Spatial resolution Diffraction limited (~wavelength) Detectors Probably MCT-A*, MCT-B (mercury cadmium telluride) Spot size at sample 2-10 µm (diffraction-limited) Sample preparation Biological preparation equipment available including incubator, biohoods, prep table, and more TBD. Sample environment N2 purged, minimal clean area (no particle specification), microcryostat/heater stages available for 4.2-730 K

84

Beamline 5.4.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Infrared spectromicroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics Bend magnet Energy range 0.07-1.25 eV Frequency range 600 - 10,000 cm-1 Interferometer resolution 0.125 cm-1 Endstations FTIR bench and IR microscope (N2 purged) Characteristics Computerized sample stage, 0.1-micron resolution; reflection, transmission, and attenuated total reflectance (ATR) modes; polarizing and UV fluorescence optics Spatial resolution Diffraction limited (~wavelength) Detectors Probably MCT-A*, MCT-B (mercury cadmium telluride) Spot size at sample 2-10 µm (diffraction-limited) Sample preparation Biological preparation equipment available including incubator, biohoods, prep table, and more TBD. Sample environment N2 purged, minimal clean area (no particle specification), microcryostat/heater stages available for 4.2-730 K

85

Beamline 5.4.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Infrared spectromicroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics Bend magnet Energy range 0.07-1.25 eV Frequency range 600 - 10,000 cm-1 Interferometer resolution 0.125 cm-1 Endstations FTIR bench and IR microscope (N2 purged) Characteristics Computerized sample stage, 0.1-micron resolution; reflection, transmission, and attenuated total reflectance (ATR) modes; polarizing and UV fluorescence optics Spatial resolution Diffraction limited (~wavelength) Detectors Probably MCT-A*, MCT-B (mercury cadmium telluride) Spot size at sample 2-10 µm (diffraction-limited) Sample preparation Biological preparation equipment available including incubator, biohoods, prep table, and more TBD. Sample environment N2 purged, minimal clean area (no particle specification), microcryostat/heater stages available for 4.2-730 K

86

Instrumentation upgrades for the Macromolecular Crystallography beamlines  

NLE Websites -- All DOE Office Websites (Extended Search)

Instrumentation upgrades for the Macromolecular Crystallography beamlines Instrumentation upgrades for the Macromolecular Crystallography beamlines of the Swiss Light Source Monday, October 29, 2012 - 2:00am SSRL, Bldg. 137, Rm. 322 Martin Fuchs, MX Group, Swiss Light Source; Paul Scherrer Institute (Villigen, Switzerland) A new unified diffractometer - the D3 - has been developed for the three MX beamlines. The first of the instruments is in general user operation at beamline X10SA since April 2012. The varied demands from both challenging academic research projects as well as high throughput industrial applications on today's macromolecular crystallography beamlines drive developments to both endstations and beamline optics. Recent instrumentation upgrades to the macromolecular crystallography (MX) beamlines of the Swiss Light Source therefore aimed to

87

Beamline 7.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and Materials Science, Spectromicroscopy Scientific disciplines: Correlated electron system, materials science Endstations: nanoARPES (nARPES) Electronic Structure Factory (ESF) Advanced x-ray inelastic scattering (AXIS) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range See endstation tables Monochromator See endstation tables Scientific disciplines Correlated electron system, materials science Website Beamline 7: http://www-bl7.lbl.gov/ ENDSTATION INFORMATION Endstation name nanoARPES Operational This instrument is currently under development. Expected user operation in 2012. For consideration, speak to the beamline scientist before applying for beamtime.

88

Beamline 10.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 0.1 Beamline 10.0.1 Print Tuesday, 20 October 2009 09:08 Photoemission of Highly Correlated Materials; High-Resolution Atomic, Molecular, and Optical Physics Scientific disciplines: AMO, correlated electron systems Endstations: High energy resolution spectrometer (HERS) High-resolution atomic and molecular electron spectrometer (HiRAMES) HRAMO-Ion-photon beamline (IPB) Velocity map imaging spectrometer Electron spin polarization (ESP) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 10-cm period undulator (U10) (first and third harmonics) Energy range 17-350 eV Monochromator SGM (gratings: 380, 925, 2100 lines/mm) Calculated and measured flux (1.9 GeV, 400 mA) Up to 1013 photons/s/0.01% BW at 30 eV

89

Beamline 7.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

7.0.1 Print 7.0.1 Print Surface and Materials Science, Spectromicroscopy Scientific disciplines: Correlated electron system, materials science Endstations: nanoARPES (nARPES) Electronic Structure Factory (ESF) Advanced x-ray inelastic scattering (AXIS) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range See endstation tables Monochromator See endstation tables Scientific disciplines Correlated electron system, materials science Website Beamline 7: http://www-bl7.lbl.gov/ ENDSTATION INFORMATION Endstation name nanoARPES Operational This instrument is currently under development. Expected user operation in 2012. For consideration, speak to the beamline scientist before applying for beamtime.

90

Beamline 7.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and Materials Science, Spectromicroscopy Scientific disciplines: Correlated electron system, materials science Endstations: nanoARPES (nARPES) Electronic Structure Factory (ESF) Advanced x-ray inelastic scattering (AXIS) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range See endstation tables Monochromator See endstation tables Scientific disciplines Correlated electron system, materials science Website Beamline 7: http://www-bl7.lbl.gov/ ENDSTATION INFORMATION Endstation name nanoARPES Operational This instrument is currently under development. Expected user operation in 2012. For consideration, speak to the beamline scientist before applying for beamtime.

91

Beamline 10.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 0.1 Beamline 10.0.1 Print Tuesday, 20 October 2009 09:08 Photoemission of Highly Correlated Materials; High-Resolution Atomic, Molecular, and Optical Physics Scientific disciplines: AMO, correlated electron systems Endstations: High energy resolution spectrometer (HERS) High-resolution atomic and molecular electron spectrometer (HiRAMES) HRAMO-Ion-photon beamline (IPB) Velocity map imaging spectrometer Electron spin polarization (ESP) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 10-cm period undulator (U10) (first and third harmonics) Energy range 17-350 eV Monochromator SGM (gratings: 380, 925, 2100 lines/mm) Calculated and measured flux (1.9 GeV, 400 mA) Up to 1013 photons/s/0.01% BW at 30 eV

92

Beamline 7.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and Materials Science, Spectromicroscopy Scientific disciplines: Correlated electron system, materials science Endstations: nanoARPES (nARPES) Electronic Structure Factory (ESF) Advanced x-ray inelastic scattering (AXIS) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range See endstation tables Monochromator See endstation tables Scientific disciplines Correlated electron system, materials science Website Beamline 7: http://www-bl7.lbl.gov/ ENDSTATION INFORMATION Endstation name nanoARPES Operational This instrument is currently under development. Expected user operation in 2012. For consideration, speak to the beamline scientist before applying for beamtime.

93

Beamline 7.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and Materials Science, Spectromicroscopy Scientific disciplines: Correlated electron system, materials science Endstations: nanoARPES (nARPES) Electronic Structure Factory (ESF) Advanced x-ray inelastic scattering (AXIS) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range See endstation tables Monochromator See endstation tables Scientific disciplines Correlated electron system, materials science Website Beamline 7: http://www-bl7.lbl.gov/ ENDSTATION INFORMATION Endstation name nanoARPES Operational This instrument is currently under development. Expected user operation in 2012. For consideration, speak to the beamline scientist before applying for beamtime.

94

Beamline 7.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and Materials Science, Spectromicroscopy Scientific disciplines: Correlated electron system, materials science Endstations: nanoARPES (nARPES) Electronic Structure Factory (ESF) Advanced x-ray inelastic scattering (AXIS) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range See endstation tables Monochromator See endstation tables Scientific disciplines Correlated electron system, materials science Website Beamline 7: http://www-bl7.lbl.gov/ ENDSTATION INFORMATION Endstation name nanoARPES Operational This instrument is currently under development. Expected user operation in 2012. For consideration, speak to the beamline scientist before applying for beamtime.

95

Beamline 7.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and Materials Science, Spectromicroscopy Scientific disciplines: Correlated electron system, materials science Endstations: nanoARPES (nARPES) Electronic Structure Factory (ESF) Advanced x-ray inelastic scattering (AXIS) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range See endstation tables Monochromator See endstation tables Scientific disciplines Correlated electron system, materials science Website Beamline 7: http://www-bl7.lbl.gov/ ENDSTATION INFORMATION Endstation name nanoARPES Operational This instrument is currently under development. Expected user operation in 2012. For consideration, speak to the beamline scientist before applying for beamtime.

96

ALS Beamlines Directory  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamlines Directory Print Beamlines Directory Print Beamlines, Parameters, Contact Information, and Schedules Download a high-resolution version of the ALS Beamclock. See Beamclock to view the ALS energy-related beamlines beamclock. Beamline Parameters Beamline and endstation technical information is available through the links below. Unless otherwise noted, all beamlines are currently operational. Individual beamline schedules are posted when available. Please contact the responsible beamline scientist for additional schedule information. When calling from off-site, all beamline (BL) phone numbers that begin with a "2" are preceded by 495- (i.e., 495-2014); all others are preceded by 486-. Beamline Number Source Technique/ Group Name Energy Range Beamline Contact Schedule/BL Phone

97

ALS Beamlines Directory  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamlines Directory Print Beamlines Directory Print Beamlines, Parameters, Contact Information, and Schedules Download a high-resolution version of the ALS Beamclock. See Beamclock to view the ALS energy-related beamlines beamclock. Beamline Parameters Beamline and endstation technical information is available through the links below. Unless otherwise noted, all beamlines are currently operational. Individual beamline schedules are posted when available. Please contact the responsible beamline scientist for additional schedule information. When calling from off-site, all beamline (BL) phone numbers that begin with a "2" are preceded by 495- (i.e., 495-2014); all others are preceded by 486-. Beamline Number Source Technique/ Group Name Energy Range Beamline Contact Schedule/BL Phone

98

ALS Beamlines Directory  

NLE Websites -- All DOE Office Websites (Extended Search)

ALS Beamlines Directory Print ALS Beamlines Directory Print Beamlines, Parameters, Contact Information, and Schedules Download a high-resolution version of the ALS Beamclock. See Beamclock to view the ALS energy-related beamlines beamclock. Beamline Parameters Beamline and endstation technical information is available through the links below. Unless otherwise noted, all beamlines are currently operational. Individual beamline schedules are posted when available. Please contact the responsible beamline scientist for additional schedule information. When calling from off-site, all beamline (BL) phone numbers that begin with a "2" are preceded by 495- (i.e., 495-2014); all others are preceded by 486-. Beamline Number Source Technique/ Group Name Energy Range Beamline Contact Schedule/BL Phone

99

ALS Beamlines Directory  

NLE Websites -- All DOE Office Websites (Extended Search)

ALS Beamlines Directory Print ALS Beamlines Directory Print Beamlines, Parameters, Contact Information, and Schedules Download a high-resolution version of the ALS Beamclock. See Beamclock to view the ALS energy-related beamlines beamclock. Beamline Parameters Beamline and endstation technical information is available through the links below. Unless otherwise noted, all beamlines are currently operational. Individual beamline schedules are posted when available. Please contact the responsible beamline scientist for additional schedule information. When calling from off-site, all beamline (BL) phone numbers that begin with a "2" are preceded by 495- (i.e., 495-2014); all others are preceded by 486-. Beamline Number Source Technique/ Group Name Energy Range Beamline Contact Schedule/BL Phone

100

ALS Beamlines Directory  

NLE Websites -- All DOE Office Websites (Extended Search)

Parameters, Contact Information, and Schedules Download a high-resolution version of the ALS Beamclock. See Beamclock to view the ALS energy-related beamlines beamclock. Beamline...

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Beamline 7.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Diagnostic beamline GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range Port 1: ~17 keV transmission though Mo filters Port 2: IR-visible from large-angle synchrotron radiation; UV-x-ray for beam position monitor (BPM) Endstations Port 1: Hard x-ray to visible converter (phosphor) Port 2: None (available for temporary experiments) Both ports are inside the ALS shielding. Characteristics Port 1: Pinhole-based x-ray system for transverse measurements Port 2: IR/visible port available for temporary experiments; x-ray BPM based on electron secondary emission induced in metallic blades by synchrotron radiation Spatial resolution Port 1: <25 µm transverse Port 2: ~1 µm position; <1 µrad angle (x-ray BPM)

102

Beamline 7.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Diagnostic beamline GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range Port 1: ~17 keV transmission though Mo filters Port 2: IR-visible from large-angle synchrotron radiation; UV-x-ray for beam position monitor (BPM) Endstations Port 1: Hard x-ray to visible converter (phosphor) Port 2: None (available for temporary experiments) Both ports are inside the ALS shielding. Characteristics Port 1: Pinhole-based x-ray system for transverse measurements Port 2: IR/visible port available for temporary experiments; x-ray BPM based on electron secondary emission induced in metallic blades by synchrotron radiation Spatial resolution Port 1: <25 µm transverse Port 2: ~1 µm position; <1 µrad angle (x-ray BPM)

103

Beamline 7.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Diagnostic beamline GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range Port 1: ~17 keV transmission though Mo filters Port 2: IR-visible from large-angle synchrotron radiation; UV-x-ray for beam position monitor (BPM) Endstations Port 1: Hard x-ray to visible converter (phosphor) Port 2: None (available for temporary experiments) Both ports are inside the ALS shielding. Characteristics Port 1: Pinhole-based x-ray system for transverse measurements Port 2: IR/visible port available for temporary experiments; x-ray BPM based on electron secondary emission induced in metallic blades by synchrotron radiation Spatial resolution Port 1: <25 µm transverse Port 2: ~1 µm position; <1 µrad angle (x-ray BPM)

104

Beamline 7.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Diagnostic beamline GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range Port 1: ~17 keV transmission though Mo filters Port 2: IR-visible from large-angle synchrotron radiation; UV-x-ray for beam position monitor (BPM) Endstations Port 1: Hard x-ray to visible converter (phosphor) Port 2: None (available for temporary experiments) Both ports are inside the ALS shielding. Characteristics Port 1: Pinhole-based x-ray system for transverse measurements Port 2: IR/visible port available for temporary experiments; x-ray BPM based on electron secondary emission induced in metallic blades by synchrotron radiation Spatial resolution Port 1: <25 µm transverse Port 2: ~1 µm position; <1 µrad angle (x-ray BPM)

105

APS Beamline 6-ID-B,C  

NLE Websites -- All DOE Office Websites (Extended Search)

B,C Home B,C Home Recent Publications Beamline Info Optics Instrumentation Software User Info Beamline 6-ID-B,C Beamline 6-ID-B,C is operated by the Magnetic Materials Group in the X-ray Science Division (XSD) of the Advanced Photon Source. Research on this beamline centers on general x-ray scattering studies of materials. The beamline has 2 end-stations: 6-ID-B: Psi -Diffractomter & In-Field Studies 6-ID-C: UHV in-situ growth Recent Research Highlights LSMO pictures Searching for Next-Generation Electronic Materials December 14, 2009 A new class of layered oxide materials discovered thanks to research at the beamline 6-ID-B offers scientists unprecedented opportunities for creating the next generation of electronic devices. Local Contact: Phil Ryan Local Contacts: Philip Ryan (Surface Diffraction) 630.252.0252 ryan@aps.anl.gov

106

Beamline 10.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Photoemission of Highly Correlated Materials; High-Resolution Atomic, Molecular, and Optical Physics Scientific disciplines: AMO, correlated electron systems Endstations: High energy resolution spectrometer (HERS) High-resolution atomic and molecular electron spectrometer (HiRAMES) HRAMO-Ion-photon beamline (IPB) Velocity map imaging spectrometer Electron spin polarization (ESP) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 10-cm period undulator (U10) (first and third harmonics) Energy range 17-350 eV Monochromator SGM (gratings: 380, 925, 2100 lines/mm) Calculated and measured flux (1.9 GeV, 400 mA) Up to 1013 photons/s/0.01% BW at 30 eV Resolving power (E/ΔE)

107

Beamline 12.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

2.0.1 Print 2.0.1 Print EUV optics testing and interferometry, angle- and spin-resolved photoemission Scientific discipline: Applied science, correlated electron systems Endstations: Angle- and spin-resolved photoemission (12.0.1.1) Berkeley Dose Calibration Tool (DCT)(12.0.1.2) SEMATECH Berkeley Microfield Exposure Tool (MET) (12.0.1.3) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 8-cm-period undulator (U8) Energy range See endstation tables Monochromator See endstation tables Endstations Angle- and spin-resolved photoemission (12.0.1.1) SEMATECH Berkeley Microfield Exposure Tool (MET) (12.0.1.2) Berkeley Dose Calibration Tool (DCT)(12.0.1.3) Beamline phone numbers (510) 495-2121 (12.0.1.1)

108

Beamline 9.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

9.3.2 9.3.2 Beamline 9.3.2 Print Tuesday, 20 October 2009 09:06 Chemical and Materials Scientific disciplines: Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry Endstations: Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)* Ambient pressure photoemission GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 30-850 eV Monochromator SGM (gratings: 100, 600 lines/mm) Calculated flux (1.9 GeV, 400 mA) up to 1.5 x 1011 photons/sec, energy dependent Resolving power (E/ΔE) <10,000 Scientific disciplines Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry. Endstations Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)*

109

Beamline 12.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

2.0.1 Print 2.0.1 Print EUV optics testing and interferometry, angle- and spin-resolved photoemission Scientific discipline: Applied science, correlated electron systems Endstations: Angle- and spin-resolved photoemission (12.0.1.1) Berkeley Dose Calibration Tool (DCT)(12.0.1.2) SEMATECH Berkeley Microfield Exposure Tool (MET) (12.0.1.3) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 8-cm-period undulator (U8) Energy range See endstation tables Monochromator See endstation tables Endstations Angle- and spin-resolved photoemission (12.0.1.1) SEMATECH Berkeley Microfield Exposure Tool (MET) (12.0.1.2) Berkeley Dose Calibration Tool (DCT)(12.0.1.3) Beamline phone numbers (510) 495-2121 (12.0.1.1)

110

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 0.1 Beamline 8.0.1 Print Tuesday, 20 October 2009 08:51 Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE)

111

Beamline 10.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Photoemission of Highly Correlated Materials; High-Resolution Atomic, Molecular, and Optical Physics Scientific disciplines: AMO, correlated electron systems Endstations: High energy resolution spectrometer (HERS) High-resolution atomic and molecular electron spectrometer (HiRAMES) HRAMO-Ion-photon beamline (IPB) Velocity map imaging spectrometer Electron spin polarization (ESP) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 10-cm period undulator (U10) (first and third harmonics) Energy range 17-350 eV Monochromator SGM (gratings: 380, 925, 2100 lines/mm) Calculated and measured flux (1.9 GeV, 400 mA) Up to 1013 photons/s/0.01% BW at 30 eV Resolving power (E/ΔE)

112

Beamline 10.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Photoemission of Highly Correlated Materials; High-Resolution Atomic, Molecular, and Optical Physics Scientific disciplines: AMO, correlated electron systems Endstations: High energy resolution spectrometer (HERS) High-resolution atomic and molecular electron spectrometer (HiRAMES) HRAMO-Ion-photon beamline (IPB) Velocity map imaging spectrometer Electron spin polarization (ESP) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 10-cm period undulator (U10) (first and third harmonics) Energy range 17-350 eV Monochromator SGM (gratings: 380, 925, 2100 lines/mm) Calculated and measured flux (1.9 GeV, 400 mA) Up to 1013 photons/s/0.01% BW at 30 eV Resolving power (E/ΔE)

113

Beamline 10.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Photoemission of Highly Correlated Materials; High-Resolution Atomic, Molecular, and Optical Physics Scientific disciplines: AMO, correlated electron systems Endstations: High energy resolution spectrometer (HERS) High-resolution atomic and molecular electron spectrometer (HiRAMES) HRAMO-Ion-photon beamline (IPB) Velocity map imaging spectrometer Electron spin polarization (ESP) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 10-cm period undulator (U10) (first and third harmonics) Energy range 17-350 eV Monochromator SGM (gratings: 380, 925, 2100 lines/mm) Calculated and measured flux (1.9 GeV, 400 mA) Up to 1013 photons/s/0.01% BW at 30 eV Resolving power (E/ΔE)

114

Beamline 12.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2.2 2.2 Beamline 12.2.2 Print Tuesday, 20 October 2009 09:31 High-Pressure (California High-Pressure Science Observatory: Calipso) Endstations: Medium pressure High pressure laser heating GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Superbend magnet, 1.9GeV, 5.29Tesla, 500mA Monochromator Si(111) or Multilayer Energy range 6-40 keV for Si(111), 14-28 keV for Multilayer Resolving power (E/ΔE) Si(111) = 7000, Multilayer =100 Beam size (HxV) Focused: 10 x 10 micron Unfocused: 90 x 100 micron Scientific applications High-pressure science Scientific disciplines Earth sciences, materials science, construction materials, chemistry, energy. Endstations Medium pressure High pressure laser heating

115

Beamline 12.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

2.0.1 Print 2.0.1 Print EUV optics testing and interferometry, angle- and spin-resolved photoemission Scientific discipline: Applied science, correlated electron systems Endstations: Angle- and spin-resolved photoemission (12.0.1.1) Berkeley Dose Calibration Tool (DCT)(12.0.1.2) SEMATECH Berkeley Microfield Exposure Tool (MET) (12.0.1.3) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 8-cm-period undulator (U8) Energy range See endstation tables Monochromator See endstation tables Endstations Angle- and spin-resolved photoemission (12.0.1.1) SEMATECH Berkeley Microfield Exposure Tool (MET) (12.0.1.2) Berkeley Dose Calibration Tool (DCT)(12.0.1.3) Beamline phone numbers (510) 495-2121 (12.0.1.1)

116

Beamline 12.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

2.0.1 Print 2.0.1 Print EUV optics testing and interferometry, angle- and spin-resolved photoemission Scientific discipline: Applied science, correlated electron systems Endstations: Angle- and spin-resolved photoemission (12.0.1.1) Berkeley Dose Calibration Tool (DCT)(12.0.1.2) SEMATECH Berkeley Microfield Exposure Tool (MET) (12.0.1.3) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 8-cm-period undulator (U8) Energy range See endstation tables Monochromator See endstation tables Endstations Angle- and spin-resolved photoemission (12.0.1.1) SEMATECH Berkeley Microfield Exposure Tool (MET) (12.0.1.2) Berkeley Dose Calibration Tool (DCT)(12.0.1.3) Beamline phone numbers (510) 495-2121 (12.0.1.1)

117

Beamline 10.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Photoemission of Highly Correlated Materials; High-Resolution Atomic, Molecular, and Optical Physics Scientific disciplines: AMO, correlated electron systems Endstations: High energy resolution spectrometer (HERS) High-resolution atomic and molecular electron spectrometer (HiRAMES) HRAMO-Ion-photon beamline (IPB) Velocity map imaging spectrometer Electron spin polarization (ESP) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 10-cm period undulator (U10) (first and third harmonics) Energy range 17-350 eV Monochromator SGM (gratings: 380, 925, 2100 lines/mm) Calculated and measured flux (1.9 GeV, 400 mA) Up to 1013 photons/s/0.01% BW at 30 eV Resolving power (E/ΔE)

118

Beamline 10.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Photoemission of Highly Correlated Materials; High-Resolution Atomic, Molecular, and Optical Physics Scientific disciplines: AMO, correlated electron systems Endstations: High energy resolution spectrometer (HERS) High-resolution atomic and molecular electron spectrometer (HiRAMES) HRAMO-Ion-photon beamline (IPB) Velocity map imaging spectrometer Electron spin polarization (ESP) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 10-cm period undulator (U10) (first and third harmonics) Energy range 17-350 eV Monochromator SGM (gratings: 380, 925, 2100 lines/mm) Calculated and measured flux (1.9 GeV, 400 mA) Up to 1013 photons/s/0.01% BW at 30 eV Resolving power (E/ΔE)

119

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 0.1 Beamline 8.0.1 Print Tuesday, 20 October 2009 08:51 Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE)

120

Beamline 10.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Photoemission of Highly Correlated Materials; High-Resolution Atomic, Molecular, and Optical Physics Scientific disciplines: AMO, correlated electron systems Endstations: High energy resolution spectrometer (HERS) High-resolution atomic and molecular electron spectrometer (HiRAMES) HRAMO-Ion-photon beamline (IPB) Velocity map imaging spectrometer Electron spin polarization (ESP) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 10-cm period undulator (U10) (first and third harmonics) Energy range 17-350 eV Monochromator SGM (gratings: 380, 925, 2100 lines/mm) Calculated and measured flux (1.9 GeV, 400 mA) Up to 1013 photons/s/0.01% BW at 30 eV Resolving power (E/ΔE)

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Beamline 10.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Photoemission of Highly Correlated Materials; High-Resolution Atomic, Molecular, and Optical Physics Scientific disciplines: AMO, correlated electron systems Endstations: High energy resolution spectrometer (HERS) High-resolution atomic and molecular electron spectrometer (HiRAMES) HRAMO-Ion-photon beamline (IPB) Velocity map imaging spectrometer Electron spin polarization (ESP) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 10-cm period undulator (U10) (first and third harmonics) Energy range 17-350 eV Monochromator SGM (gratings: 380, 925, 2100 lines/mm) Calculated and measured flux (1.9 GeV, 400 mA) Up to 1013 photons/s/0.01% BW at 30 eV Resolving power (E/ΔE)

122

Beamline 12.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

2.0.1 Print 2.0.1 Print EUV optics testing and interferometry, angle- and spin-resolved photoemission Scientific discipline: Applied science, correlated electron systems Endstations: Angle- and spin-resolved photoemission (12.0.1.1) Berkeley Dose Calibration Tool (DCT)(12.0.1.2) SEMATECH Berkeley Microfield Exposure Tool (MET) (12.0.1.3) GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 8-cm-period undulator (U8) Energy range See endstation tables Monochromator See endstation tables Endstations Angle- and spin-resolved photoemission (12.0.1.1) SEMATECH Berkeley Microfield Exposure Tool (MET) (12.0.1.2) Berkeley Dose Calibration Tool (DCT)(12.0.1.3) Beamline phone numbers (510) 495-2121 (12.0.1.1)

123

LENGTH OF BEAMLINES AND WIDTH OF THE LS-37  

NLE Websites -- All DOE Office Websites (Extended Search)

LENGTH OF BEAMLINES AND WIDTH OF THE LENGTH OF BEAMLINES AND WIDTH OF THE LS-37 November 10, 1985 G. K. Shenoy G. S. Knapp EXPERIMENTAL HALL AT A 6-GeV SYNCHROTRON FACILITY The width of the experimental hall at a 6-GeV facility is closely related to the length of the beamlines. This note addresses this aspect in some de tail. In general, no two beamlines will have identical lengths or the placement of various optical elements. Hence fixing the beamline lengths prior to their assignment to specific experiments is difficult. In spite of this fact, a few general conclusions are made. 1. At least 25m of all the beamlines will be behind the shielding wall. Within this length many beamline components can be accommodated as shown in Fig. 1. 2. For most beamlines on bending magnets (BM), the first optical element will

124

Beamline Temperatures  

NLE Websites -- All DOE Office Websites (Extended Search)

Temperatures Temperatures Energy: 3.0000 GeV Current: 493.2242 mA Date: 11-Jan-2014 21:40:00 Beamline Temperatures Energy 3.0000 GeV Current 493.2 mA 11-Jan-2014 21:40:00 LN:MainTankLevel 124.4 in LN:MainTankPress 56.9 psi SPEAR-BL:B120HeFlow 15.4 l/min SPEAR-BL:B131HeFlow 22.2 l/min BL 4 BL02:LCW 0.0 ℃ BL02:M0_LCW 31.5 ℃ BL 4-1 BL04-1:BasePlate -14.0 ℃ BL04-1:Bottom1 46.0 ℃ BL04-1:Bottom2 47.0 ℃ BL04-1:Lower 32.0 ℃ BL04-1:Moly 46.0 ℃ BL04-1:ChinGuard1 31.0 ℃ BL04-1:ChinGuard2 31.0 ℃ BL04-1:FirstXtalA -167.0 ℃ BL04-1:FirstXtalB -172.0 ℃ BL04-1:Pad1 31.0 ℃ BL04-1:Pad2 31.0 ℃ BL04-1:SecondXtalA -177.0 ℃ BL04-1:SecondXtalB -175.0 ℃ BL 4-2 BL04-2:BasePlate -14.0 ℃ BL04-2:Bottom1 24.0 ℃ BL04-2:Bottom2 25.0 ℃

125

Final Beamline Design Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Final Beamline Design Report Final Beamline Design Report Guidelines and Review Criteria (SCD 1.20.95) 6.0 Final Beamline Design Report (FDR) Overview The Final Beamline Design Report is part of the Advanced Photon Source (APS) beamline review process and should be planned for when approximately 90% of the total beamline design has been completed. Fifteen copies of the FDR are to be submitted to the APS Users Office. Approval of the Collaborative Access Team's (CAT) designs described in the report is required prior to installation of beamline components in the APS Experiment Hall. Components that have a long lead time for design or procurement can be reviewed separately from the remainder of the beamline, but enough information must be provided so that the reviewer can understand the

126

Beamline Advisory Committees  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamline Advisory Committees 4-ID Dr. Dario Arena (Brookhaven National Lab, NSLS), chair Prof. Jaq Chakhalian ( Univesity of Arkansas) Dr. Axel Hoffmann ( Argonne National Lab,...

127

Beamline 9.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

3.2 Print 3.2 Print Chemical and Materials Scientific disciplines: Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry Endstations: Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)* Ambient pressure photoemission GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 30-850 eV Monochromator SGM (gratings: 100, 600 lines/mm) Calculated flux (1.9 GeV, 400 mA) up to 1.5 x 1011 photons/sec, energy dependent Resolving power (E/ΔE) <10,000 Scientific disciplines Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry. Endstations Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)*

128

Beamline 12.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2.2 Print 2.2 Print High-Pressure (California High-Pressure Science Observatory: Calipso) Endstations: Medium pressure High pressure laser heating GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Superbend magnet, 1.9GeV, 5.29Tesla, 500mA Monochromator Si(111) or Multilayer Energy range 6-40 keV for Si(111), 14-28 keV for Multilayer Resolving power (E/ΔE) Si(111) = 7000, Multilayer =100 Beam size (HxV) Focused: 10 x 10 micron Unfocused: 90 x 100 micron Scientific applications High-pressure science Scientific disciplines Earth sciences, materials science, construction materials, chemistry, energy. Endstations Medium pressure High pressure laser heating Experimental techniques High pressure, diffraction, x-ray imaging, XAS, laser heating

129

Beamline 12.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2.2 Print 2.2 Print High-Pressure (California High-Pressure Science Observatory: Calipso) Endstations: Medium pressure High pressure laser heating GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Superbend magnet, 1.9GeV, 5.29Tesla, 500mA Monochromator Si(111) or Multilayer Energy range 6-40 keV for Si(111), 14-28 keV for Multilayer Resolving power (E/ΔE) Si(111) = 7000, Multilayer =100 Beam size (HxV) Focused: 10 x 10 micron Unfocused: 90 x 100 micron Scientific applications High-pressure science Scientific disciplines Earth sciences, materials science, construction materials, chemistry, energy. Endstations Medium pressure High pressure laser heating Experimental techniques High pressure, diffraction, x-ray imaging, XAS, laser heating

130

Beamline 9.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

3.2 Print 3.2 Print Chemical and Materials Scientific disciplines: Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry Endstations: Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)* Ambient pressure photoemission GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 30-850 eV Monochromator SGM (gratings: 100, 600 lines/mm) Calculated flux (1.9 GeV, 400 mA) up to 1.5 x 1011 photons/sec, energy dependent Resolving power (E/ΔE) <10,000 Scientific disciplines Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry. Endstations Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)*

131

Beamline 9.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Chemical and Materials Scientific disciplines: Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry Endstations: Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)* Ambient pressure photoemission GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 30-850 eV Monochromator SGM (gratings: 100, 600 lines/mm) Calculated flux (1.9 GeV, 400 mA) up to 1.5 x 1011 photons/sec, energy dependent Resolving power (E/ΔE) <10,000 Scientific disciplines Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry. Endstations Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)*

132

Beamline 12.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2.2 Print 2.2 Print High-Pressure (California High-Pressure Science Observatory: Calipso) Endstations: Medium pressure High pressure laser heating GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Superbend magnet, 1.9GeV, 5.29Tesla, 500mA Monochromator Si(111) or Multilayer Energy range 6-40 keV for Si(111), 14-28 keV for Multilayer Resolving power (E/ΔE) Si(111) = 7000, Multilayer =100 Beam size (HxV) Focused: 10 x 10 micron Unfocused: 90 x 100 micron Scientific applications High-pressure science Scientific disciplines Earth sciences, materials science, construction materials, chemistry, energy. Endstations Medium pressure High pressure laser heating Experimental techniques High pressure, diffraction, x-ray imaging, XAS, laser heating

133

Beamline 11.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print PEEM3, Soft X-Ray Scattering Scientific disciplines: Magnetism, materials, surface science, polymers Endstations: 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 150-2000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 800 eV Resolving power (E/ΔE) 4,000 at 800 eV Endstations 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization

134

Beamline 9.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Chemical and Materials Scientific disciplines: Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry Endstations: Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)* Ambient pressure photoemission GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 30-850 eV Monochromator SGM (gratings: 100, 600 lines/mm) Calculated flux (1.9 GeV, 400 mA) up to 1.5 x 1011 photons/sec, energy dependent Resolving power (E/ΔE) <10,000 Scientific disciplines Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry. Endstations Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)*

135

Beamline 11.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print PEEM3, Soft X-Ray Scattering Scientific disciplines: Magnetism, materials, surface science, polymers Endstations: 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 150-2000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 800 eV Resolving power (E/ΔE) 4,000 at 800 eV Endstations 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization

136

Beamline 12.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Coherent science Scientific disciplines: Applied science, magnetism, materials science Endstations: 12.0.2.1: Coherent optics 12.0.2.2: Coherent x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Third harmonic of 8-cm-period undulator (U8) Energy range 300-1500 eV Monochromator VLS-PGM, with two gratings (600 and 1200 lines/mm) Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 500 eV Resolving power (E/DE) 1,000 Beam size Focused: 70 x 10 µm Unfocused: 200 x 200 µm Endstations 12.0.2.1: Coherent optics 12.0.2.2: Coherent scattering Detectors DetectorsCCD, photodiode, scintillator Scientific applications Branchlines designed for spatially coherent soft x-ray experiments

137

Beamline 12.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Coherent science Scientific disciplines: Applied science, magnetism, materials science Endstations: 12.0.2.1: Coherent optics 12.0.2.2: Coherent x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Third harmonic of 8-cm-period undulator (U8) Energy range 300-1500 eV Monochromator VLS-PGM, with two gratings (600 and 1200 lines/mm) Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 500 eV Resolving power (E/DE) 1,000 Beam size Focused: 70 x 10 µm Unfocused: 200 x 200 µm Endstations 12.0.2.1: Coherent optics 12.0.2.2: Coherent scattering Detectors DetectorsCCD, photodiode, scintillator Scientific applications Branchlines designed for spatially coherent soft x-ray experiments

138

Beamline 11.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print PEEM3, Soft X-Ray Scattering Scientific disciplines: Magnetism, materials, surface science, polymers Endstations: 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 150-2000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 800 eV Resolving power (E/ΔE) 4,000 at 800 eV Endstations 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization

139

Beamline 9.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Chemical and Materials Scientific disciplines: Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry Endstations: Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)* Ambient pressure photoemission GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 30-850 eV Monochromator SGM (gratings: 100, 600 lines/mm) Calculated flux (1.9 GeV, 400 mA) up to 1.5 x 1011 photons/sec, energy dependent Resolving power (E/ΔE) <10,000 Scientific disciplines Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry. Endstations Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)*

140

Beamline 9.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Chemical and Materials Scientific disciplines: Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry Endstations: Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)* Ambient pressure photoemission GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 30-850 eV Monochromator SGM (gratings: 100, 600 lines/mm) Calculated flux (1.9 GeV, 400 mA) up to 1.5 x 1011 photons/sec, energy dependent Resolving power (E/ΔE) <10,000 Scientific disciplines Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry. Endstations Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)*

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Beamline 12.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

0.2 Print 0.2 Print Coherent science Scientific disciplines: Applied science, magnetism, materials science Endstations: 12.0.2.1: Coherent optics 12.0.2.2: Coherent x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Third harmonic of 8-cm-period undulator (U8) Energy range 300-1500 eV Monochromator VLS-PGM, with two gratings (600 and 1200 lines/mm) Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 500 eV Resolving power (E/DE) 1,000 Beam size Focused: 70 x 10 µm Unfocused: 200 x 200 µm Endstations 12.0.2.1: Coherent optics 12.0.2.2: Coherent scattering Detectors DetectorsCCD, photodiode, scintillator Scientific applications Branchlines designed for spatially coherent soft x-ray experiments

142

Beamline 9.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Chemical and Materials Scientific disciplines: Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry Endstations: Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)* Ambient pressure photoemission GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 30-850 eV Monochromator SGM (gratings: 100, 600 lines/mm) Calculated flux (1.9 GeV, 400 mA) up to 1.5 x 1011 photons/sec, energy dependent Resolving power (E/ΔE) <10,000 Scientific disciplines Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry. Endstations Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)*

143

Beamline 12.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2.2 Print 2.2 Print High-Pressure (California High-Pressure Science Observatory: Calipso) Endstations: Medium pressure High pressure laser heating GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Superbend magnet, 1.9GeV, 5.29Tesla, 500mA Monochromator Si(111) or Multilayer Energy range 6-40 keV for Si(111), 14-28 keV for Multilayer Resolving power (E/ΔE) Si(111) = 7000, Multilayer =100 Beam size (HxV) Focused: 10 x 10 micron Unfocused: 90 x 100 micron Scientific applications High-pressure science Scientific disciplines Earth sciences, materials science, construction materials, chemistry, energy. Endstations Medium pressure High pressure laser heating Experimental techniques High pressure, diffraction, x-ray imaging, XAS, laser heating

144

Beamline 12.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Coherent science Scientific disciplines: Applied science, magnetism, materials science Endstations: 12.0.2.1: Coherent optics 12.0.2.2: Coherent x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Third harmonic of 8-cm-period undulator (U8) Energy range 300-1500 eV Monochromator VLS-PGM, with two gratings (600 and 1200 lines/mm) Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 500 eV Resolving power (E/DE) 1,000 Beam size Focused: 70 x 10 µm Unfocused: 200 x 200 µm Endstations 12.0.2.1: Coherent optics 12.0.2.2: Coherent scattering Detectors DetectorsCCD, photodiode, scintillator Scientific applications Branchlines designed for spatially coherent soft x-ray experiments

145

Beamline 11.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print PEEM3, Soft X-Ray Scattering Scientific disciplines: Magnetism, materials, surface science, polymers Endstations: 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 150-2000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 800 eV Resolving power (E/ΔE) 4,000 at 800 eV Endstations 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization

146

Beamline 9.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

3.2 Print 3.2 Print Chemical and Materials Scientific disciplines: Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry Endstations: Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)* Ambient pressure photoemission GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 30-850 eV Monochromator SGM (gratings: 100, 600 lines/mm) Calculated flux (1.9 GeV, 400 mA) up to 1.5 x 1011 photons/sec, energy dependent Resolving power (E/ΔE) <10,000 Scientific disciplines Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry. Endstations Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)*

147

Beamline 11.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print PEEM3, Soft X-Ray Scattering Scientific disciplines: Magnetism, materials, surface science, polymers Endstations: 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 150-2000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 800 eV Resolving power (E/ΔE) 4,000 at 800 eV Endstations 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization

148

Beamline 11.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print PEEM3, Soft X-Ray Scattering Scientific disciplines: Magnetism, materials, surface science, polymers Endstations: 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 150-2000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 800 eV Resolving power (E/ΔE) 4,000 at 800 eV Endstations 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization

149

Beamline 12.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Coherent science Scientific disciplines: Applied science, magnetism, materials science Endstations: 12.0.2.1: Coherent optics 12.0.2.2: Coherent x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Third harmonic of 8-cm-period undulator (U8) Energy range 300-1500 eV Monochromator VLS-PGM, with two gratings (600 and 1200 lines/mm) Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 500 eV Resolving power (E/DE) 1,000 Beam size Focused: 70 x 10 µm Unfocused: 200 x 200 µm Endstations 12.0.2.1: Coherent optics 12.0.2.2: Coherent scattering Detectors DetectorsCCD, photodiode, scintillator Scientific applications Branchlines designed for spatially coherent soft x-ray experiments

150

Beamline 12.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2.2 Print 2.2 Print High-Pressure (California High-Pressure Science Observatory: Calipso) Endstations: Medium pressure High pressure laser heating GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Superbend magnet, 1.9GeV, 5.29Tesla, 500mA Monochromator Si(111) or Multilayer Energy range 6-40 keV for Si(111), 14-28 keV for Multilayer Resolving power (E/ΔE) Si(111) = 7000, Multilayer =100 Beam size (HxV) Focused: 10 x 10 micron Unfocused: 90 x 100 micron Scientific applications High-pressure science Scientific disciplines Earth sciences, materials science, construction materials, chemistry, energy. Endstations Medium pressure High pressure laser heating Experimental techniques High pressure, diffraction, x-ray imaging, XAS, laser heating

151

Beamline 11.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print PEEM3, Soft X-Ray Scattering Scientific disciplines: Magnetism, materials, surface science, polymers Endstations: 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 150-2000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 800 eV Resolving power (E/ΔE) 4,000 at 800 eV Endstations 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization

152

Beamline 9.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

3.2 Print 3.2 Print Chemical and Materials Scientific disciplines: Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry Endstations: Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)* Ambient pressure photoemission GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Bend magnet Energy range 30-850 eV Monochromator SGM (gratings: 100, 600 lines/mm) Calculated flux (1.9 GeV, 400 mA) up to 1.5 x 1011 photons/sec, energy dependent Resolving power (E/ΔE) <10,000 Scientific disciplines Surfaces, interfaces, catalysis, environmental science, material science, electrochemistry. Endstations Ambient pressure X-ray Photoelectron Spectroscopy (APXPS)*

153

Beamline 7.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

7.3.1 Print 7.3.1 Print Photoemission electron microscope PEEM2 Scientific disciplines: Magnetism, materials, surface science, polymers Note: This beamline is NOT open to general users. GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 180-1500 eV Monochromator SGM Calculated flux (1.9 GeV, 400 mA) 3 x 1012 photons/s/0.1%BW at 800 eV (linearly polarized) Resolving power (E/ΔE) 1,000 Endstations Photoemission electron microscope (PEEM2) Characteristics X-ray absorption spectromicroscopy Spatial resolution Below 100 nm Detectors Slow scan CCD Spot size at sample 30 x 30 µm Sample format UHV-compatible flat, conductive samples up to 1 cm2 in area Sample preparation Sputter-cleaning, heating, e-beam and sputter evaporation, LEED, transfer capability, magnet (1 kOe)

154

Beamline 11.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print PEEM3, Soft X-Ray Scattering Scientific disciplines: Magnetism, materials, surface science, polymers Endstations: 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 150-2000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 800 eV Resolving power (E/ΔE) 4,000 at 800 eV Endstations 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization

155

Beamline 11.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print PEEM3, Soft X-Ray Scattering Scientific disciplines: Magnetism, materials, surface science, polymers Endstations: 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 150-2000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 800 eV Resolving power (E/ΔE) 4,000 at 800 eV Endstations 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization

156

Beamline 7.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

7.3.1 Print 7.3.1 Print Photoemission electron microscope PEEM2 Scientific disciplines: Magnetism, materials, surface science, polymers Note: This beamline is NOT open to general users. GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 180-1500 eV Monochromator SGM Calculated flux (1.9 GeV, 400 mA) 3 x 1012 photons/s/0.1%BW at 800 eV (linearly polarized) Resolving power (E/ΔE) 1,000 Endstations Photoemission electron microscope (PEEM2) Characteristics X-ray absorption spectromicroscopy Spatial resolution Below 100 nm Detectors Slow scan CCD Spot size at sample 30 x 30 µm Sample format UHV-compatible flat, conductive samples up to 1 cm2 in area Sample preparation Sputter-cleaning, heating, e-beam and sputter evaporation, LEED, transfer capability, magnet (1 kOe)

157

Beamline 12.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2.2 Print 2.2 Print High-Pressure (California High-Pressure Science Observatory: Calipso) Endstations: Medium pressure High pressure laser heating GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Superbend magnet, 1.9GeV, 5.29Tesla, 500mA Monochromator Si(111) or Multilayer Energy range 6-40 keV for Si(111), 14-28 keV for Multilayer Resolving power (E/ΔE) Si(111) = 7000, Multilayer =100 Beam size (HxV) Focused: 10 x 10 micron Unfocused: 90 x 100 micron Scientific applications High-pressure science Scientific disciplines Earth sciences, materials science, construction materials, chemistry, energy. Endstations Medium pressure High pressure laser heating Experimental techniques High pressure, diffraction, x-ray imaging, XAS, laser heating

158

Beamline 11.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print PEEM3, Soft X-Ray Scattering Scientific disciplines: Magnetism, materials, surface science, polymers Endstations: 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 150-2000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 800 eV Resolving power (E/ΔE) 4,000 at 800 eV Endstations 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization

159

Beamline 12.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2.2 Print 2.2 Print High-Pressure (California High-Pressure Science Observatory: Calipso) Endstations: Medium pressure High pressure laser heating GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Superbend magnet, 1.9GeV, 5.29Tesla, 500mA Monochromator Si(111) or Multilayer Energy range 6-40 keV for Si(111), 14-28 keV for Multilayer Resolving power (E/ΔE) Si(111) = 7000, Multilayer =100 Beam size (HxV) Focused: 10 x 10 micron Unfocused: 90 x 100 micron Scientific applications High-pressure science Scientific disciplines Earth sciences, materials science, construction materials, chemistry, energy. Endstations Medium pressure High pressure laser heating Experimental techniques High pressure, diffraction, x-ray imaging, XAS, laser heating

160

Beamline 12.2.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2.2 Print 2.2 Print High-Pressure (California High-Pressure Science Observatory: Calipso) Endstations: Medium pressure High pressure laser heating GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Superbend magnet, 1.9GeV, 5.29Tesla, 500mA Monochromator Si(111) or Multilayer Energy range 6-40 keV for Si(111), 14-28 keV for Multilayer Resolving power (E/ΔE) Si(111) = 7000, Multilayer =100 Beam size (HxV) Focused: 10 x 10 micron Unfocused: 90 x 100 micron Scientific applications High-pressure science Scientific disciplines Earth sciences, materials science, construction materials, chemistry, energy. Endstations Medium pressure High pressure laser heating Experimental techniques High pressure, diffraction, x-ray imaging, XAS, laser heating

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Beamline 12.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Coherent science Scientific disciplines: Applied science, magnetism, materials science Endstations: 12.0.2.1: Coherent optics 12.0.2.2: Coherent x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Third harmonic of 8-cm-period undulator (U8) Energy range 300-1500 eV Monochromator VLS-PGM, with two gratings (600 and 1200 lines/mm) Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 500 eV Resolving power (E/DE) 1,000 Beam size Focused: 70 x 10 µm Unfocused: 200 x 200 µm Endstations 12.0.2.1: Coherent optics 12.0.2.2: Coherent scattering Detectors DetectorsCCD, photodiode, scintillator Scientific applications Branchlines designed for spatially coherent soft x-ray experiments

162

Beamline 12.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Coherent science Scientific disciplines: Applied science, magnetism, materials science Endstations: 12.0.2.1: Coherent optics 12.0.2.2: Coherent x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Third harmonic of 8-cm-period undulator (U8) Energy range 300-1500 eV Monochromator VLS-PGM, with two gratings (600 and 1200 lines/mm) Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 500 eV Resolving power (E/DE) 1,000 Beam size Focused: 70 x 10 µm Unfocused: 200 x 200 µm Endstations 12.0.2.1: Coherent optics 12.0.2.2: Coherent scattering Detectors DetectorsCCD, photodiode, scintillator Scientific applications Branchlines designed for spatially coherent soft x-ray experiments

163

Beamline 11.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print PEEM3, Soft X-Ray Scattering Scientific disciplines: Magnetism, materials, surface science, polymers Endstations: 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 150-2000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 800 eV Resolving power (E/ΔE) 4,000 at 800 eV Endstations 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization

164

Beamline 12.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2.0.2 Print 2.0.2 Print Coherent science Scientific disciplines: Applied science, magnetism, materials science Endstations: 12.0.2.1: Coherent optics 12.0.2.2: Coherent x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Third harmonic of 8-cm-period undulator (U8) Energy range 300-1500 eV Monochromator VLS-PGM, with two gratings (600 and 1200 lines/mm) Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 500 eV Resolving power (E/DE) 1,000 Beam size Focused: 70 x 10 µm Unfocused: 200 x 200 µm Endstations 12.0.2.1: Coherent optics 12.0.2.2: Coherent scattering Detectors DetectorsCCD, photodiode, scintillator Scientific applications Branchlines designed for spatially coherent soft x-ray experiments

165

Beamline Commissioning Readiness Review Team  

NLE Websites -- All DOE Office Websites (Extended Search)

AES AES CCSM & BCRRT Chair J. Vacca AES RSO-Health Physicist W. VanWingeren AES AES Commissioning Coordinator Floor Coordinator AES Beamline Operations Support Beamline Staff...

166

Beamline 4.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print High-resolution spectroscopy of complex materials (MERLIN) Endstations: MERIXS: High-resolution inelastic scattering ARPES: Angle-resolved photoemission spectroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics 9.0-cm-period quasiperiodic elliptical polarization undulator (EPU9) Energy range 9eV-120eV with current gratings Monochromator Variable-included-angle spherical grating monochromator (SGM) Calculated flux (1.9 GeV, 400 mA) 1012 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) High flux 1200 lines/mm; ~1/25,000 Endstations High-resolution inelastic scattering (MERIXS) and ARPES Characteristics Milli-Electron-volt Resolution beamLINe (MERLIN): Ultrahigh-resolution inelastic scattering and angle-resolved photoemission

167

Beamline 4.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print High-resolution spectroscopy of complex materials (MERLIN) Endstations: MERIXS: High-resolution inelastic scattering ARPES: Angle-resolved photoemission spectroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics 9.0-cm-period quasiperiodic elliptical polarization undulator (EPU9) Energy range 9eV-120eV with current gratings Monochromator Variable-included-angle spherical grating monochromator (SGM) Calculated flux (1.9 GeV, 400 mA) 1012 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) High flux 1200 lines/mm; ~1/25,000 Endstations High-resolution inelastic scattering (MERIXS) and ARPES Characteristics Milli-Electron-volt Resolution beamLINe (MERLIN): Ultrahigh-resolution inelastic scattering and angle-resolved photoemission

168

Beamline 4.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print High-resolution spectroscopy of complex materials (MERLIN) Endstations: MERIXS: High-resolution inelastic scattering ARPES: Angle-resolved photoemission spectroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics 9.0-cm-period quasiperiodic elliptical polarization undulator (EPU9) Energy range 9eV-120eV with current gratings Monochromator Variable-included-angle spherical grating monochromator (SGM) Calculated flux (1.9 GeV, 400 mA) 1012 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) High flux 1200 lines/mm; ~1/25,000 Endstations High-resolution inelastic scattering (MERIXS) and ARPES Characteristics Milli-Electron-volt Resolution beamLINe (MERLIN): Ultrahigh-resolution inelastic scattering and angle-resolved photoemission

169

Beamline 4.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print High-resolution spectroscopy of complex materials (MERLIN) Endstations: MERIXS: High-resolution inelastic scattering ARPES: Angle-resolved photoemission spectroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics 9.0-cm-period quasiperiodic elliptical polarization undulator (EPU9) Energy range 9eV-120eV with current gratings Monochromator Variable-included-angle spherical grating monochromator (SGM) Calculated flux (1.9 GeV, 400 mA) 1012 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) High flux 1200 lines/mm; ~1/25,000 Endstations High-resolution inelastic scattering (MERIXS) and ARPES Characteristics Milli-Electron-volt Resolution beamLINe (MERLIN): Ultrahigh-resolution inelastic scattering and angle-resolved photoemission

170

Beamline 4.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print High-resolution spectroscopy of complex materials (MERLIN) Endstations: MERIXS: High-resolution inelastic scattering ARPES: Angle-resolved photoemission spectroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics 9.0-cm-period quasiperiodic elliptical polarization undulator (EPU9) Energy range 9eV-120eV with current gratings Monochromator Variable-included-angle spherical grating monochromator (SGM) Calculated flux (1.9 GeV, 400 mA) 1012 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) High flux 1200 lines/mm; ~1/25,000 Endstations High-resolution inelastic scattering (MERIXS) and ARPES Characteristics Milli-Electron-volt Resolution beamLINe (MERLIN): Ultrahigh-resolution inelastic scattering and angle-resolved photoemission

171

Beamline 4.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print High-resolution spectroscopy of complex materials (MERLIN) Endstations: MERIXS: High-resolution inelastic scattering ARPES: Angle-resolved photoemission spectroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics 9.0-cm-period quasiperiodic elliptical polarization undulator (EPU9) Energy range 9eV-120eV with current gratings Monochromator Variable-included-angle spherical grating monochromator (SGM) Calculated flux (1.9 GeV, 400 mA) 1012 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) High flux 1200 lines/mm; ~1/25,000 Endstations High-resolution inelastic scattering (MERIXS) and ARPES Characteristics Milli-Electron-volt Resolution beamLINe (MERLIN): Ultrahigh-resolution inelastic scattering and angle-resolved photoemission

172

Beamline 9.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

9.0.2 9.0.2 Beamline 9.0.2 Print Tuesday, 20 October 2009 08:59 Chemical Dynamics Scientific disciplines: Chemical dynamics, aerosol chemistry, imaging mass spectrometry, chemical kinetics, laser ablation and clusters, combustion and flames. Endstations: Molecular-beam photoelectron/photoion imaging and spectroscopy Flame chamber Ablation chamber Aerosol chamber Kinetics chamber GENERAL BEAMLINE INFORMATION Operational Yes Source characteristics 10-cm period undulator (U10) (fundamental) Energy range 7.4-30 eV Undulator beam White beam (straight undulator beam) Calculated flux (1.9 GeV, 400 mA) 1016 photons/s, 2.5%BW Spot size at sample 170 (h) x 50 (v) µm Monochromator #1 3-m Off-plane Eagle Calculated flux (1.9 GeV, 400 mA) 1014 photons/s, 0.1%BW Spot size at sample 400 (h) x 350 (v) µm

173

Beamlines Directory | Advanced Photon Source  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamlines Directory Beamlines Directory Filter by: L bracket Discipline: All Atomic Physics Chemistry Environmental Science GeoScience Life Sciences Materials Science Physics Polymer Science Technique: All Anomalous and resonant scattering (hard x-ray) Anomalous and resonant scattering (soft x-ray) Biohazards at the BSL2/3 level Coherent x-ray scattering Diffraction anomalous fine structure Diffuse x-ray scattering Energy dispersive X-ray diffraction Fiber diffraction Fluorescence spectroscopy General diffraction Grazing incidence diffraction Grazing incidence small-angle scattering High-energy x-ray diffraction High-pressure diamond anvil cell High-pressure multi-anvil press Inelastic x-ray scattering Inelastic x-ray scattering (1 eV resolution) Intensity fluctuation spectroscopy Large unit cell crystallography Laue

174

Beamline 4.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print High-resolution spectroscopy of complex materials (MERLIN) Endstations: MERIXS: High-resolution inelastic scattering ARPES: Angle-resolved photoemission spectroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics 9.0-cm-period quasiperiodic elliptical polarization undulator (EPU9) Energy range 9eV-120eV with current gratings Monochromator Variable-included-angle spherical grating monochromator (SGM) Calculated flux (1.9 GeV, 400 mA) 1012 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) High flux 1200 lines/mm; ~1/25,000 Endstations High-resolution inelastic scattering (MERIXS) and ARPES Characteristics Milli-Electron-volt Resolution beamLINe (MERLIN): Ultrahigh-resolution inelastic scattering and angle-resolved photoemission

175

Beamline 4.0.3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Print 3 Print High-resolution spectroscopy of complex materials (MERLIN) Endstations: MERIXS: High-resolution inelastic scattering ARPES: Angle-resolved photoemission spectroscopy GENERAL BEAMLINE INFORMATION Operational 2011 Source characteristics 9.0-cm-period quasiperiodic elliptical polarization undulator (EPU9) Energy range 9eV-120eV with current gratings Monochromator Variable-included-angle spherical grating monochromator (SGM) Calculated flux (1.9 GeV, 400 mA) 1012 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) High flux 1200 lines/mm; ~1/25,000 Endstations High-resolution inelastic scattering (MERIXS) and ARPES Characteristics Milli-Electron-volt Resolution beamLINe (MERLIN): Ultrahigh-resolution inelastic scattering and angle-resolved photoemission

176

Beamline 10.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.3.1 0.3.1 Beamline 10.3.1 Print Tuesday, 20 October 2009 09:14 X-ray fluorescence microprobe Scientific disciplines: Environmental science, detector development, low-dose radiation effects in cells GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 3-20 keV Monochromator White light, multilayer mirrors in Kirkpatrick-Baez configuration Calculated flux (1.9 GeV, 400 mA) 3 x 1010 photons/s at 12.5 keV Resolving power (E/ΔE) White light to 30 at 12 keV Endstations Large hutch with optical table Characteristics X-ray fluorescence analysis of samples with high elemental sensitivity and high spatial resolution Spatial resolution 10 x 10 µm Detectors Silicon drift detector Spot size at sample 1.0 x 1.2 µm Sample format

177

Beamline 12.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

0.2 0.2 Beamline 12.0.2 Print Tuesday, 20 October 2009 09:30 Coherent science Scientific disciplines: Applied science, magnetism, materials science Endstations: 12.0.2.1: Coherent optics 12.0.2.2: Coherent x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics Third harmonic of 8-cm-period undulator (U8) Energy range 300-1500 eV Monochromator VLS-PGM, with two gratings (600 and 1200 lines/mm) Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 500 eV Resolving power (E/DE) 1,000 Beam size Focused: 70 x 10 µm Unfocused: 200 x 200 µm Endstations 12.0.2.1: Coherent optics 12.0.2.2: Coherent scattering Detectors DetectorsCCD, photodiode, scintillator Scientific applications Branchlines designed for spatially coherent soft x-ray experiments

178

Beamline 11.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 1 Beamline 11.0.1 Print Tuesday, 20 October 2009 09:16 PEEM3, Soft X-Ray Scattering Scientific disciplines: Magnetism, materials, surface science, polymers Endstations: 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 150-2000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1013 photons/s/0.1%BW at 800 eV Resolving power (E/ΔE) 4,000 at 800 eV Endstations 11.0.1.1: Photoemission electron microscope (PEEM3) 11.0.1.2: Soft x-ray scattering Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization

179

Genome-wide binding of the orphan nuclear receptor TR4 suggests its general role in fundamental biological processes  

E-Print Network (OSTI)

its general role in fundamental biological processes. BMCits general role in fundamental biological processesgenes are involved in fundamental biological processes such

2010-01-01T23:59:59.000Z

180

NSLS Committees | Beamline Vacuum Committee  

NLE Websites -- All DOE Office Websites (Extended Search)

Vacuum Committee Charge Ensure that beamline designs, on both VUV Ring and the X-Ray Ring, adhere to the vacuum standards set forth for the entire facility. When a new beamline or...

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Beamline 4.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

4.0.2 Print 4.0.2 Print Magnetic spectroscopy Scientific disciplines: Magnetism, materials science Endstations: Eight-pole electromagnet XMCD chamber (6T, 2K) L-edge chamber with superconducting spectrometer GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 100-2000 eV Monochromator Variable-included-angle PGM Calculated flux (1.9 GeV, 400 mA) 1 x 1013 photons/s/0.1%BW at 800 eV [Value reported is the merit function, flux = total flux x (degree of circular polarization)2.] Resolving power (E/ΔE) 5,000-10,000 (at source-size limit; energy-dependent) >25,000 (64 eV, 10-mm entrance/exit slits) Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization.

182

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE) 7000 Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

183

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

8.0.1 Print 8.0.1 Print Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE) 7000 Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

184

Beamline 4.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Magnetic spectroscopy Scientific disciplines: Magnetism, materials science Endstations: Eight-pole electromagnet XMCD chamber (6T, 2K) L-edge chamber with superconducting spectrometer GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 100-2000 eV Monochromator Variable-included-angle PGM Calculated flux (1.9 GeV, 400 mA) 1 x 1013 photons/s/0.1%BW at 800 eV [Value reported is the merit function, flux = total flux x (degree of circular polarization)2.] Resolving power (E/ΔE) 5,000-10,000 (at source-size limit; energy-dependent) >25,000 (64 eV, 10-mm entrance/exit slits) Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization.

185

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE) 7000 Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

186

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

8.0.1 Print 8.0.1 Print Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE) 7000 Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

187

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE) 7000 Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

188

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE) 7000 Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

189

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

8.0.1 Print 8.0.1 Print Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE) 7000 Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

190

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE) 7000 Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

191

Beamline 4.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Magnetic spectroscopy Scientific disciplines: Magnetism, materials science Endstations: Eight-pole electromagnet XMCD chamber (6T, 2K) L-edge chamber with superconducting spectrometer GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 100-2000 eV Monochromator Variable-included-angle PGM Calculated flux (1.9 GeV, 400 mA) 1 x 1013 photons/s/0.1%BW at 800 eV [Value reported is the merit function, flux = total flux x (degree of circular polarization)2.] Resolving power (E/ΔE) 5,000-10,000 (at source-size limit; energy-dependent) >25,000 (64 eV, 10-mm entrance/exit slits) Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization.

192

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE) 7000 Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

193

Beamline 4.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Magnetic spectroscopy Scientific disciplines: Magnetism, materials science Endstations: Eight-pole electromagnet XMCD chamber (6T, 2K) L-edge chamber with superconducting spectrometer GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 100-2000 eV Monochromator Variable-included-angle PGM Calculated flux (1.9 GeV, 400 mA) 1 x 1013 photons/s/0.1%BW at 800 eV [Value reported is the merit function, flux = total flux x (degree of circular polarization)2.] Resolving power (E/ΔE) 5,000-10,000 (at source-size limit; energy-dependent) >25,000 (64 eV, 10-mm entrance/exit slits) Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization.

194

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE) 7000 Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

195

Beamline 4.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Magnetic spectroscopy Scientific disciplines: Magnetism, materials science Endstations: Eight-pole electromagnet XMCD chamber (6T, 2K) L-edge chamber with superconducting spectrometer GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 100-2000 eV Monochromator Variable-included-angle PGM Calculated flux (1.9 GeV, 400 mA) 1 x 1013 photons/s/0.1%BW at 800 eV [Value reported is the merit function, flux = total flux x (degree of circular polarization)2.] Resolving power (E/ΔE) 5,000-10,000 (at source-size limit; energy-dependent) >25,000 (64 eV, 10-mm entrance/exit slits) Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization.

196

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE) 7000 Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

197

Beamline 4.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Magnetic spectroscopy Scientific disciplines: Magnetism, materials science Endstations: Eight-pole electromagnet XMCD chamber (6T, 2K) L-edge chamber with superconducting spectrometer GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 100-2000 eV Monochromator Variable-included-angle PGM Calculated flux (1.9 GeV, 400 mA) 1 x 1013 photons/s/0.1%BW at 800 eV [Value reported is the merit function, flux = total flux x (degree of circular polarization)2.] Resolving power (E/ΔE) 5,000-10,000 (at source-size limit; energy-dependent) >25,000 (64 eV, 10-mm entrance/exit slits) Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization.

198

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE) 7000 Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

199

Beamline 8.0.1  

NLE Websites -- All DOE Office Websites (Extended Search)

0.1 Print 0.1 Print Surface and materials science, soft x-ray fluorescence (SXF), open port Scientific disciplines: Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system Endstations: 8.0.1.1: Soft x-ray fluorescence (SXF) spectrometer 8.0.1.2: Open port 8.0.1.3: Wet-RIXS 8.0.1.4: Nano-NEXAFS 8.0.1.5: Bio-NEXAFS GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5-cm period undulator (U5) (first, third, and fifth harmonics) Energy range 80-1250 eV Monochromator SGM (gratings: 150, 380, 925 lines/mm) Flux (1.9 GeV, 400 mA) 1011 to 6 x 1015 photons/s (resolution and energy dependent) Resolving power (E/ΔE) 7000 Scientific disciplines Green energy sciences, material sciences, nanosciences, surfaces sciences, correlated electron system.

200

Beamline 4.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Magnetic spectroscopy Scientific disciplines: Magnetism, materials science Endstations: Eight-pole electromagnet XMCD chamber (6T, 2K) L-edge chamber with superconducting spectrometer GENERAL BEAMLINE INFORMATION Operational Yes Proposal cycle Proposals for General Sciences Beamlines (6-month cycle) Source characteristics 5.0-cm period elliptical polarization undulator (EPU5) Energy range 100-2000 eV Monochromator Variable-included-angle PGM Calculated flux (1.9 GeV, 400 mA) 1 x 1013 photons/s/0.1%BW at 800 eV [Value reported is the merit function, flux = total flux x (degree of circular polarization)2.] Resolving power (E/ΔE) 5,000-10,000 (at source-size limit; energy-dependent) >25,000 (64 eV, 10-mm entrance/exit slits) Special notes Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization.

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Beamline 1.4.4  

NLE Websites -- All DOE Office Websites (Extended Search)

1.4.4 Print Infrared spectromicroscopy Scientific disciplines: Biology, correlated electron systems, environmental science, geology, chemistry, polymers, soft materials GENERAL...

202

Biology Department - Brookhaven National Laboratory  

NLE Websites -- All DOE Office Websites (Extended Search)

National Laboratory From: 1599- 61400 Past BNL Research Interests I am the biology beamline scientist at x-ray beamline X25 at the National Synchrotron Light Source and...

203

APS 7-BM Beamline: Beamline Controls and Data Handling  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamline Controls and Data Acquisition Beamline Controls and Data Acquisition Beamline controls operate through EPICS, with the standard MEDM graphical interface. When needed, Python is used for scripting, based on the PyEpics implementation written by CARS. The beamline workstation has access to the Enthought Python Distribution, which includes many common Python packages, such as numpy, scipy, h5py, and others. Data formats Time resolved data collected at the beamline are typically stored in a locally-defined binary data file. For distribution to users, these files are converted to HDF5, a widely used, hierarchical binary data format that can be accessed using tools in a wide variety of programming languages. Other formats can potentially be accommodated upon request; please contact beamline staff prior to your beamtime if a different format is needed.

204

BNL | ATF Beamline Parameters  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamline Parameters Beamline Parameters Electron beam energy: 25 to 76 MeV Temporal structure: Macropulse length: 3 microseconds Macropulse repetition rate from under 1 PPS to 3 PPS. Micropulse repetition period 12.25 ns or 24.5 ns. Micropulse length variable from about 1 ps FWHM to 10 ps FWHM. Electron beam charge: continuously variable. Single micropulse charge from zero to a few nanoculombs. Bunch train charge up to about 10 nanoculombs. Emittance: depends on various conditions, e.g. peak current, gun field, microbunch length etc. At 1 nC we have measured the emittance at 2.6 mm mrad (rms normalized) at a bunch length of 10 ps FWHM. The local emittance (Slice Emittance) is smaller, measured 1.4 mm mrad for a slice out of the 1 nC bunch. Stability: (approx.) 1 ps in short term phase, 1% of beam diameter

205

BEAMLINE 4-2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 2 CURRENT STATUS: Open SUPPORTED TECHNIQUES: Biological Small Angle X-ray Scattering/Diffraction Macromolecular solution x-ray scattering Lipid membrane diffraction Fiber diffraction Time-resolved x-ray scattering/diffraction Small-angle single crystal diffraction Ultra small-angle x-ray scattering (under development) MAIN SCIENTIFIC DISCIPLINES: Biology % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 20-pole, 2.0-Tesla Wiggler ID End Station BEAM LINE SPECIFICATIONS: energy range grating type resolution DE/E spot size flux angular acceptance focused (crystal) 6000-18000 eV ~5 x 10-4 ~0.2 x 1.0mm < 1.0 mrad focused (multilayers) 8000-12000 eV ~3 x 10-2 ~0.2 x 1.0mm < 1.0 mrad

206

Beamline 9.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Chemical Dynamics Scientific disciplines: Chemical dynamics, aerosol chemistry, imaging mass spectrometry, chemical kinetics, laser ablation and clusters, combustion and flames. Endstations: Molecular-beam photoelectron/photoion imaging and spectroscopy Flame chamber Ablation chamber Aerosol chamber Kinetics chamber GENERAL BEAMLINE INFORMATION Operational Yes Source characteristics 10-cm period undulator (U10) (fundamental) Energy range 7.4-30 eV Undulator beam White beam (straight undulator beam) Calculated flux (1.9 GeV, 400 mA) 1016 photons/s, 2.5%BW Spot size at sample 170 (h) x 50 (v) µm Monochromator #1 3-m Off-plane Eagle Calculated flux (1.9 GeV, 400 mA) 1014 photons/s, 0.1%BW Spot size at sample 400 (h) x 350 (v) µm Monochromator #2 3-m Off-plane Eagle

207

Beamline 9.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Atomic, molecular, and materials science Endstations: X-ray absorption endstation Polarized-x-ray emission spectrometer Magnetic mass spectrometer Liquid cell endstation GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 2320eV-5600eV Monochromator Double Si(111) crystal Measured flux (1.9 GeV, 300 mA) 1011 photons/s Resolving power (E/ΔE) 3000-8000 Beam size Adjustable with 2nd mirror Focused: 1.0 mm x 0.7 mm (~0.5 mm square at 2800 eV) Unfocused: 10 mm x 10 mm or larger Endstations X-ray absorption endstation Polarized-x-ray emission spectrometer Magnetic mass spectrometer Liquid cell endstation Local contact Wayne Stolte Advanced Light Source, Berkeley Lab Phone: (510) 486-5804 Fax: (510) 495-2111

208

Beamline 10.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print X-ray fluorescence microprobe Scientific disciplines: Environmental science, detector development, low-dose radiation effects in cells GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 3-20 keV Monochromator White light, multilayer mirrors in Kirkpatrick-Baez configuration Calculated flux (1.9 GeV, 400 mA) 3 x 1010 photons/s at 12.5 keV Resolving power (E/ΔE) White light to 30 at 12 keV Endstations Large hutch with optical table Characteristics X-ray fluorescence analysis of samples with high elemental sensitivity and high spatial resolution Spatial resolution 10 x 10 µm Detectors Silicon drift detector Spot size at sample 1.0 x 1.2 µm Sample format Sample size flexible up to 30 cm x 1 meter depending on configuration.

209

Beamline 3.2.1  

NLE Websites -- All DOE Office Websites (Extended Search)

2.1 Print 2.1 Print Commercial deep-etch x-ray lithography (LIGA) GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 3-12 keV Monochromator None Endstations Hutch with automated scanner Calculated spot size at sample 100 x 10 mm Sample format 3- and 4-in. wafer format; x-ray mask and LIGA substrate Sample environment Ambient, air Scientific disciplines Applied science Scientific applications Deep-etch x-ray lithography (LIGA) Spokesperson This e-mail address is being protected from spambots. You need JavaScript enabled to view it Advanced Light Source, Berkeley Lab Phone: (510) 486-5527 Fax: (510) 486-4102 This e-mail address is being protected from spambots. You need JavaScript enabled to view it AXSUN Technology

210

Beamline 10.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print X-ray fluorescence microprobe Scientific disciplines: Environmental science, detector development, low-dose radiation effects in cells GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 3-20 keV Monochromator White light, multilayer mirrors in Kirkpatrick-Baez configuration Calculated flux (1.9 GeV, 400 mA) 3 x 1010 photons/s at 12.5 keV Resolving power (E/ΔE) White light to 30 at 12 keV Endstations Large hutch with optical table Characteristics X-ray fluorescence analysis of samples with high elemental sensitivity and high spatial resolution Spatial resolution 10 x 10 µm Detectors Silicon drift detector Spot size at sample 1.0 x 1.2 µm Sample format Sample size flexible up to 30 cm x 1 meter depending on configuration.

211

Beamline 9.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Atomic, molecular, and materials science Endstations: X-ray absorption endstation Polarized-x-ray emission spectrometer Magnetic mass spectrometer Liquid cell endstation GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 2320eV-5600eV Monochromator Double Si(111) crystal Measured flux (1.9 GeV, 300 mA) 1011 photons/s Resolving power (E/ΔE) 3000-8000 Beam size Adjustable with 2nd mirror Focused: 1.0 mm x 0.7 mm (~0.5 mm square at 2800 eV) Unfocused: 10 mm x 10 mm or larger Endstations X-ray absorption endstation Polarized-x-ray emission spectrometer Magnetic mass spectrometer Liquid cell endstation Local contact Wayne Stolte Advanced Light Source, Berkeley Lab Phone: (510) 486-5804 Fax: (510) 495-2111

212

Beamline 3.2.1  

NLE Websites -- All DOE Office Websites (Extended Search)

2.1 Print 2.1 Print Commercial deep-etch x-ray lithography (LIGA) GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 3-12 keV Monochromator None Endstations Hutch with automated scanner Calculated spot size at sample 100 x 10 mm Sample format 3- and 4-in. wafer format; x-ray mask and LIGA substrate Sample environment Ambient, air Scientific disciplines Applied science Scientific applications Deep-etch x-ray lithography (LIGA) Spokesperson This e-mail address is being protected from spambots. You need JavaScript enabled to view it Advanced Light Source, Berkeley Lab Phone: (510) 486-5527 Fax: (510) 486-4102 This e-mail address is being protected from spambots. You need JavaScript enabled to view it AXSUN Technology

213

Beamline 9.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

9.0.2 Print 9.0.2 Print Chemical Dynamics Scientific disciplines: Chemical dynamics, aerosol chemistry, imaging mass spectrometry, chemical kinetics, laser ablation and clusters, combustion and flames. Endstations: Molecular-beam photoelectron/photoion imaging and spectroscopy Flame chamber Ablation chamber Aerosol chamber Kinetics chamber GENERAL BEAMLINE INFORMATION Operational Yes Source characteristics 10-cm period undulator (U10) (fundamental) Energy range 7.4-30 eV Undulator beam White beam (straight undulator beam) Calculated flux (1.9 GeV, 400 mA) 1016 photons/s, 2.5%BW Spot size at sample 170 (h) x 50 (v) µm Monochromator #1 3-m Off-plane Eagle Calculated flux (1.9 GeV, 400 mA) 1014 photons/s, 0.1%BW Spot size at sample 400 (h) x 350 (v) µm Monochromator #2 3-m Off-plane Eagle

214

Beamline 3.2.1  

NLE Websites -- All DOE Office Websites (Extended Search)

2.1 Print 2.1 Print Commercial deep-etch x-ray lithography (LIGA) GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 3-12 keV Monochromator None Endstations Hutch with automated scanner Calculated spot size at sample 100 x 10 mm Sample format 3- and 4-in. wafer format; x-ray mask and LIGA substrate Sample environment Ambient, air Scientific disciplines Applied science Scientific applications Deep-etch x-ray lithography (LIGA) Spokesperson This e-mail address is being protected from spambots. You need JavaScript enabled to view it Advanced Light Source, Berkeley Lab Phone: (510) 486-5527 Fax: (510) 486-4102 This e-mail address is being protected from spambots. You need JavaScript enabled to view it AXSUN Technology

215

Beamline 9.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

9.0.2 Print 9.0.2 Print Chemical Dynamics Scientific disciplines: Chemical dynamics, aerosol chemistry, imaging mass spectrometry, chemical kinetics, laser ablation and clusters, combustion and flames. Endstations: Molecular-beam photoelectron/photoion imaging and spectroscopy Flame chamber Ablation chamber Aerosol chamber Kinetics chamber GENERAL BEAMLINE INFORMATION Operational Yes Source characteristics 10-cm period undulator (U10) (fundamental) Energy range 7.4-30 eV Undulator beam White beam (straight undulator beam) Calculated flux (1.9 GeV, 400 mA) 1016 photons/s, 2.5%BW Spot size at sample 170 (h) x 50 (v) µm Monochromator #1 3-m Off-plane Eagle Calculated flux (1.9 GeV, 400 mA) 1014 photons/s, 0.1%BW Spot size at sample 400 (h) x 350 (v) µm Monochromator #2 3-m Off-plane Eagle

216

Beamline 10.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print X-ray fluorescence microprobe Scientific disciplines: Environmental science, detector development, low-dose radiation effects in cells GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 3-20 keV Monochromator White light, multilayer mirrors in Kirkpatrick-Baez configuration Calculated flux (1.9 GeV, 400 mA) 3 x 1010 photons/s at 12.5 keV Resolving power (E/ΔE) White light to 30 at 12 keV Endstations Large hutch with optical table Characteristics X-ray fluorescence analysis of samples with high elemental sensitivity and high spatial resolution Spatial resolution 10 x 10 µm Detectors Silicon drift detector Spot size at sample 1.0 x 1.2 µm Sample format Sample size flexible up to 30 cm x 1 meter depending on configuration.

217

Beamline 10.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print X-ray fluorescence microprobe Scientific disciplines: Environmental science, detector development, low-dose radiation effects in cells GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 3-20 keV Monochromator White light, multilayer mirrors in Kirkpatrick-Baez configuration Calculated flux (1.9 GeV, 400 mA) 3 x 1010 photons/s at 12.5 keV Resolving power (E/ΔE) White light to 30 at 12 keV Endstations Large hutch with optical table Characteristics X-ray fluorescence analysis of samples with high elemental sensitivity and high spatial resolution Spatial resolution 10 x 10 µm Detectors Silicon drift detector Spot size at sample 1.0 x 1.2 µm Sample format Sample size flexible up to 30 cm x 1 meter depending on configuration.

218

Beamline 9.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Print 2 Print Chemical Dynamics Scientific disciplines: Chemical dynamics, aerosol chemistry, imaging mass spectrometry, chemical kinetics, laser ablation and clusters, combustion and flames. Endstations: Molecular-beam photoelectron/photoion imaging and spectroscopy Flame chamber Ablation chamber Aerosol chamber Kinetics chamber GENERAL BEAMLINE INFORMATION Operational Yes Source characteristics 10-cm period undulator (U10) (fundamental) Energy range 7.4-30 eV Undulator beam White beam (straight undulator beam) Calculated flux (1.9 GeV, 400 mA) 1016 photons/s, 2.5%BW Spot size at sample 170 (h) x 50 (v) µm Monochromator #1 3-m Off-plane Eagle Calculated flux (1.9 GeV, 400 mA) 1014 photons/s, 0.1%BW Spot size at sample 400 (h) x 350 (v) µm Monochromator #2 3-m Off-plane Eagle

219

Beamline 3.2.1  

NLE Websites -- All DOE Office Websites (Extended Search)

2.1 Print 2.1 Print Commercial deep-etch x-ray lithography (LIGA) GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 3-12 keV Monochromator None Endstations Hutch with automated scanner Calculated spot size at sample 100 x 10 mm Sample format 3- and 4-in. wafer format; x-ray mask and LIGA substrate Sample environment Ambient, air Scientific disciplines Applied science Scientific applications Deep-etch x-ray lithography (LIGA) Spokesperson This e-mail address is being protected from spambots. You need JavaScript enabled to view it Advanced Light Source, Berkeley Lab Phone: (510) 486-5527 Fax: (510) 486-4102 This e-mail address is being protected from spambots. You need JavaScript enabled to view it AXSUN Technology

220

Beamline 9.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Atomic, molecular, and materials science Endstations: X-ray absorption endstation Polarized-x-ray emission spectrometer Magnetic mass spectrometer Liquid cell endstation GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 2320eV-5600eV Monochromator Double Si(111) crystal Measured flux (1.9 GeV, 300 mA) 1011 photons/s Resolving power (E/ΔE) 3000-8000 Beam size Adjustable with 2nd mirror Focused: 1.0 mm x 0.7 mm (~0.5 mm square at 2800 eV) Unfocused: 10 mm x 10 mm or larger Endstations X-ray absorption endstation Polarized-x-ray emission spectrometer Magnetic mass spectrometer Liquid cell endstation Local contact Wayne Stolte Advanced Light Source, Berkeley Lab Phone: (510) 486-5804 Fax: (510) 495-2111

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Beamline 9.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

9.0.2 Print 9.0.2 Print Chemical Dynamics Scientific disciplines: Chemical dynamics, aerosol chemistry, imaging mass spectrometry, chemical kinetics, laser ablation and clusters, combustion and flames. Endstations: Molecular-beam photoelectron/photoion imaging and spectroscopy Flame chamber Ablation chamber Aerosol chamber Kinetics chamber GENERAL BEAMLINE INFORMATION Operational Yes Source characteristics 10-cm period undulator (U10) (fundamental) Energy range 7.4-30 eV Undulator beam White beam (straight undulator beam) Calculated flux (1.9 GeV, 400 mA) 1016 photons/s, 2.5%BW Spot size at sample 170 (h) x 50 (v) µm Monochromator #1 3-m Off-plane Eagle Calculated flux (1.9 GeV, 400 mA) 1014 photons/s, 0.1%BW Spot size at sample 400 (h) x 350 (v) µm Monochromator #2 3-m Off-plane Eagle

222

Beamline 9.3.1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Print 1 Print Atomic, molecular, and materials science Endstations: X-ray absorption endstation Polarized-x-ray emission spectrometer Magnetic mass spectrometer Liquid cell endstation GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 2320eV-5600eV Monochromator Double Si(111) crystal Measured flux (1.9 GeV, 300 mA) 1011 photons/s Resolving power (E/ΔE) 3000-8000 Beam size Adjustable with 2nd mirror Focused: 1.0 mm x 0.7 mm (~0.5 mm square at 2800 eV) Unfocused: 10 mm x 10 mm or larger Endstations X-ray absorption endstation Polarized-x-ray emission spectrometer Magnetic mass spectrometer Liquid cell endstation Local contact Wayne Stolte Advanced Light Source, Berkeley Lab Phone: (510) 486-5804 Fax: (510) 495-2111

223

Beamline 3.2.1  

NLE Websites -- All DOE Office Websites (Extended Search)

2.1 Print 2.1 Print Commercial deep-etch x-ray lithography (LIGA) GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 3-12 keV Monochromator None Endstations Hutch with automated scanner Calculated spot size at sample 100 x 10 mm Sample format 3- and 4-in. wafer format; x-ray mask and LIGA substrate Sample environment Ambient, air Scientific disciplines Applied science Scientific applications Deep-etch x-ray lithography (LIGA) Spokesperson This e-mail address is being protected from spambots. You need JavaScript enabled to view it Advanced Light Source, Berkeley Lab Phone: (510) 486-5527 Fax: (510) 486-4102 This e-mail address is being protected from spambots. You need JavaScript enabled to view it AXSUN Technology

224

NSLS II: The Future National Synchrotron Light Source | 2010 Beamline  

NLE Websites -- All DOE Office Websites (Extended Search)

2010 Beamline Development Proposals - Approved Proposals 2010 Beamline Development Proposals - Approved Proposals Proposal Results Announcement Acronym Title Spokesperson Type Information 4DE 4-Dimensional Studies in Extreme Environments Donald J. Weidner, Stony Brook University 1 Slide ABS A Highly Automated Instrument for Static X-ray Scattering Measurements of Biological Molecules in Solution Lin Yang, BNL 1 Slide AIM Advanced Infrared Microspectroscopy Lisa Miller, BNL 1 Slide AMX Flexible Access Macromolecular Crystallography at an Undulator Beamline Dieter Schneider, BNL 1 Slide | Proposal BMM Hard X-ray Absorption Spectroscopy and Diffraction - Beamline for Materials Measurements Daniel Fischer, NIST 2 Slide | Proposal CDI Coherent X-ray Diffraction Ian Robinson, University College London 1 Slide | Proposal

225

Beamline Commissioning Readiness Review Team  

NLE Websites -- All DOE Office Websites (Extended Search)

Readiness Review Team (BCRRT) 1. Purpose The APS Beamline Commissioning Readiness Review Team (BCRRT) reports to and advises the AES Associate Division Director for Mechanical and...

226

BCDA Beamline Control related meetings  

NLE Websites -- All DOE Office Websites (Extended Search)

Control related meetings 071410 APS Upgrade Technical Seminar Series Beamline Control Software and Software Infrastructure (pdf) - Claude Saunders and Pete Jemian 050210 2010...

227

NSLS Committees | Beamline Review Committee  

NLE Websites -- All DOE Office Websites (Extended Search)

Scrutinize all proposed beamline constructions and modifications to ensure they meet NSLS standards for safety (including radiation shielding), vacuum, and mechanical design....

228

APS Safety Guidelines for Beamlines  

NLE Websites -- All DOE Office Websites (Extended Search)

Guidelines for Beamlines Accident Investigations LOM Shop Usage User Shop Access - Policies and Procedures User Shop Orientation User Shop Authorization Certification Form User...

229

TB-14 Section 8 - Beamline Commissioning  

NLE Websites -- All DOE Office Websites (Extended Search)

8. Beamline Commissioning (Rev. July 21, 1998) A beamline commissioning process has been instituted to ensure that all systems are in place so that a beamline can perform in a safe...

230

APS beamline standard components handbook  

SciTech Connect

It is clear that most Advanced Photon Source (APS) Collaborative Access Team (CAT) members would like to concentrate on designing specialized equipment related to their scientific programs rather than on routine or standard beamline components. Thus, an effort is in progress at the APS to identify standard and modular components of APS beamlines. Identifying standard components is a nontrivial task because these components should support diverse beamline objectives. To assist with this effort, the APS has obtained advice and help from a Beamline Standardization and Modularization Committee consisting of experts in beamline design, construction, and operation. The staff of the Experimental Facilities Division identified various components thought to be standard items for beamlines, regardless of the specific scientific objective of a particular beamline. A generic beamline layout formed the basis for this identification. This layout is based on a double-crystal monochromator as the first optical element, with the possibility of other elements to follow. Pre-engineering designs were then made of the identified standard components. The Beamline Standardization and Modularization Committee has reviewed these designs and provided very useful input regarding the specifications of these components. We realize that there will be other configurations that may require special or modified components. This Handbook in its current version (1.1) contains descriptions, specifications, and pre-engineering design drawings of these standard components. In the future, the APS plans to add engineering drawings of identified standard beamline components. Use of standard components should result in major cost reductions for CATs in the areas of beamline design and construction.

Kuzay, T.M.

1992-01-01T23:59:59.000Z

231

ALS Beamline Design Requirements - Revision 1  

E-Print Network (OSTI)

the beamline including: Electrical power requirements e.at the ALS include: Electrical power: 480VAC, 208VAC, 120terminations, and electrical power requirements. Beamline

Heimann, Phil

2010-01-01T23:59:59.000Z

232

BEAMLINE 10-2  

NLE Websites -- All DOE Office Websites (Extended Search)

0-2 0-2 CURRENT STATUS: Open SUPPORTED TECHNIQUES: 10-2a: X-ray absorption spectroscopy; XAS imaging 10-2b: X-ray scattering MAIN SCIENTIFIC DISCIPLINES: Biology / Materials / Environmental % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 30-pole, 1.45-Tesla Wiggler ID End Station BEAM LINE SPECIFICATIONS: energy range resolution DE/E spot size flux angular acceptance focused 4500 - 30000 eV 0.2 x .43 mm 1.5 mrad unfocused 4500 - 45000 eV 2.0 x 20.0 mm 1.5 mrad OPTICS: Bent cylinder, Rh-coated, single crystal Si, M0 mirror Radii: 1500 m (adjustable) x 32.9 mm Cut off energy: 22 keV, Mean angle of incidence: 2.7 mrad MONOCHROMATOR: Si(111) f=90° or Si(220) f=90° Liquid nitrogen-cooled,

233

BEAMLINE 6-2  

NLE Websites -- All DOE Office Websites (Extended Search)

6-2 6-2 CURRENT STATUS: Open SUPPORTED TECHNIQUES: BL6-2a: Rapid-scanning xRF imaging Advanced x-ray spectroscopy (XES, XRS, RIXS) XES: Resonant and non-resonant x-ray emission spectroscopy XRS: Non-resonant x-ray Raman scattering BL6-2b: Rapid-scanning xRF imaging Advanced x-ray spectroscopy (XES, XRS, RIXS) XES: Resonant and non-resonant x-ray emission spectroscopy XRS: Non-resonant x-ray Raman scattering BL6-2c: Transmission X-ray Microscopy MAIN SCIENTIFIC DISCIPLINES: Biology / Materials / Environmental % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 56-pole, 0.9-Tesla Wiggler ID End Station BEAM LINE SPECIFICATIONS: energy range resolution DE/E spot size flux angular acceptance

234

BEAMLINE 4-3  

NLE Websites -- All DOE Office Websites (Extended Search)

4-3 4-3 CURRENT STATUS: Open SUPPORTED TECHNIQUES: X-ray Absorption Spectroscopy MAIN SCIENTIFIC DISCIPLINES: Environmental / Materials / Biology % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 20-pole, 2.0-Tesla wiggler, 0.75 mrad, side station BEAM LINE SPECIFICATIONS: energy range resolution DE/E spot size flux angular acceptance unfocused 2400-14000 eV 10-4 3 x 16 mm 0.75 mrad OPTICS: M0 mirror: Flat, bent vertically collimating, 1 m, Si, Rh-coated, cutoff 4-14 keV, LN2-cooled monochromator MONOCHROMATOR: Si(111) f=0° or Si(111) f=90° double-crystal, non-fixed exit slit Monochromator Crystal Glitch Library Crystal changes need to be scheduled and coordinated in advance with BL

235

BEAMLINE 4-1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 1 CURRENT STATUS: Open SUPPORTED TECHNIQUES: X-ray Absorption Spectroscopy MAIN SCIENTIFIC DISCIPLINES: Environmental / Materials / Chemistry / Biology % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 20-pole, 2.0-Tesla Wiggler, 0.75 mrad, side station BEAM LINE SPECIFICATIONS: energy range grating type resolution DE/E spot size flux angular acceptance unfocused 5,500-38,000eV 10-4 4x18mm 0.75 mrad OPTICS: M0 mirror: Flat, bent vertically collimating, 1 m, Si, Rh-coated, cutoff 9-23 keV, LN2-cooled monochromator. Energies over 22keV are run with the mirror out. MONOCHROMATOR: Si(220) f=0° or Si(220) f=90° double-crystal, non-fixed exit slit Monochromator Crystal Glitch Library

236

BEAMLINE 9-3  

NLE Websites -- All DOE Office Websites (Extended Search)

9-3 9-3 CURRENT STATUS: Closed (Down-pending mirror repair) SUPPORTED TECHNIQUES: X-ray absorption spectroscopy Single crystal x-ray absorption spectroscopy MAIN SCIENTIFIC DISCIPLINES: Structural Biology % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 16-pole, 2-Tesla wiggler, 2 mrad beam BEAM LINE SPECIFICATIONS: energy range resolution DE/E spot size (fwhm) flux* angular acceptance focused 5000-30000 eV 1 x 10-4 0.4 x 3 mm2 ~2 x 1012 2.0 mrad *ph/sec @100 mA / 9 keV w 1x4 mm aperture OPTICS: M0 mirror: Flat, bent, vertically collimating, 1 m, Si, Rh-coated, LN2-cooled monochromator M1 mirror: Bent, cylindrical, 1.2 m, Zerodur, Rh-coated MONOCHROMATOR: Si(220) phi=0°, Si(220) phi=90° double-crystal,

237

BEAMLINE 7-3  

NLE Websites -- All DOE Office Websites (Extended Search)

3 3 CURRENT STATUS: Open SUPPORTED TECHNIQUES: X-ray absorption spectroscopy MAIN SCIENTIFIC DISCIPLINES: Structural Biology % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 20-pole, 2-Tesla wiggler, 0.8 mrad beam, side station BEAM LINE SPECIFICATIONS: energy range resolution DE/E spot size (fwhm) flux* angular acceptance unfocused 4600-37000 eV 1 x 10-4 2 x 15 mm2 ~1 x 1012 0.8 mrad *ph/sec @100 mA / 9 keV w 2x15 mm aperture OPTICS: M0 mirror: Flat, bent, vertically collimating, 1 m, Si, Rh-coated, LN2-cooled monochromator MONOCHROMATOR: Si(220) phi=0°, Si(220) phi=90° double-crystal, non-fixed exit slit Monochromator Crystal Glitch Library Crystal changes need to be scheduled and coordinated in advance with BL

238

Beamline 29-ID  

NLE Websites -- All DOE Office Websites (Extended Search)

IEX Milestones(4/29/2013) IEX Milestones(4/29/2013) • Spring 2012 ✓ Completion of the IEX EM-VPU insertion device (photos) ✓ Installation of EM-VPU in the storage ring (photo1, photo2) ✓ Installation of high heat-load mirrors M0/M1 (photo) • Summer 2012 ✓ Testing of various polarization mode of EM-VPU with stored beam ✓ Installation of vacuum transport, support tables and diagnostic component; implementation of beamline controls and safety systems (cleanroom, FOE progress, FOE progress2) • Fall 2012 ✓ FDR approval (October 15) ✓ Installation of first optical enclosure components (photo) ✓ First light and testing of white/pink beam components (photo1, photo2) • Winter/Spring 2013 - White beam commissioning ✓ Alignment of mirrors with synchrotron beam ✓ Installation and alignment of support tables (photo)

239

Photon Sciences | NSLS-II Beamlines  

NLE Websites -- All DOE Office Websites (Extended Search)

NSLS-II Beamlines NSLS-II Beamlines beamlines Current NSLS-II Beamline Diagram The National Synchrotron Light Source II will accommodate more than 60 beamlines using 27 straight sections for insertion-device sources and 31 bending-magnet or three-pole-wiggler sources, with additional beamlines possible through canted insertion devices and multiple branches. Six beamlines were selected in 2008 and are now funded within the NSLS-II project. These project beamlines encompass research programs in inelastic x-ray scattering, hard x-ray nanoprobe, coherent hard x-ray scattering, coherent soft x-ray scattering and polarization, submicron resolution x-ray spectroscopy, and x-ray powder diffraction. For each beamline, a beamline advisory team, or BAT, has been established to represent the broader scientific community in a specific area of

240

Find a Beamline | Advanced Photon Source  

NLE Websites -- All DOE Office Websites (Extended Search)

Find a Beamline Find a Beamline The Advanced Photon Source consists of 34 sectors; each sector contains one or more beamlines. There are several resources available to help you find information about APS sectors and beamlines. Maps: Interactive Map Clicking on the link above or the picture below will take you to a page where you can see which APS beamlines are operational and relevant to your scientific interests. sectors map thumb Beamlines Map Clicking on the link above or the picture below will take you to a detailed bird's eye view of every beamline at the APS. beamline map thumb Directories: Beamlines Directory The complete listing of all APS beamlines' contacts, specifications, and status. Techniques Directory An explanation of the various research techniques in use at the APS, and a

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Beamline 6.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Beamline 6.0.2 Print Tuesday, 20 October 2009 08:40 UltrafastFemtosecond Dynamics Soft X Ray Scientific disciplines: Chemical dynamics, materials science, surfaces, interfaces...

242

Beamline 12.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 Beamline 12.0.2 Print Tuesday, 20 October 2009 09:30 Coherent science Scientific disciplines: Applied science, magnetism, materials science Endstations: 12.0.2.1: Coherent optics...

243

Beamline 12.0.2  

NLE Websites -- All DOE Office Websites (Extended Search)

0.2 Beamline 12.0.2 Print Tuesday, 20 October 2009 09:30 Coherent science Scientific disciplines: Applied science, magnetism, materials science Endstations: 12.0.2.1: Coherent...

244

Beamline 11.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

1.3.2 Print 1.3.2 Print Inspection of EUV lithography masks GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 50-1000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1011 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) 7000 Endstations The SEMATECH Berkeley Actinic Inspection Tool Detector 2048 x 2048 EUV CCD Characteristics 900-1000x zoneplate microscope Spot size at sample 1-5 microns Spatial resolution 60 nm Sample format EUV Photolithography masks: 6" glass plate, multilayer coated for normal incidence reflectivity at 13.4 nm Sample preparation Cleanroom handling Sample environment 2.0 x 10-7 Torr base pressure Scientific applications EUV lithography Local contacts/ Spokespersons This e-mail address is being protected from spambots. You need JavaScript enabled to view it

245

Beamline 11.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

1.3.2 Print 1.3.2 Print Inspection of EUV lithography masks GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 50-1000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1011 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) 7000 Endstations The SEMATECH Berkeley Actinic Inspection Tool Detector 2048 x 2048 EUV CCD Characteristics 900-1000x zoneplate microscope Spot size at sample 1-5 microns Spatial resolution 60 nm Sample format EUV Photolithography masks: 6" glass plate, multilayer coated for normal incidence reflectivity at 13.4 nm Sample preparation Cleanroom handling Sample environment 2.0 x 10-7 Torr base pressure Scientific applications EUV lithography Local contacts/ Spokespersons This e-mail address is being protected from spambots. You need JavaScript enabled to view it

246

Beamline 11.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

1.3.2 Print 1.3.2 Print Inspection of EUV lithography masks GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 50-1000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1011 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) 7000 Endstations The SEMATECH Berkeley Actinic Inspection Tool Detector 2048 x 2048 EUV CCD Characteristics 900-1000x zoneplate microscope Spot size at sample 1-5 microns Spatial resolution 60 nm Sample format EUV Photolithography masks: 6" glass plate, multilayer coated for normal incidence reflectivity at 13.4 nm Sample preparation Cleanroom handling Sample environment 2.0 x 10-7 Torr base pressure Scientific applications EUV lithography Local contacts/ Spokespersons This e-mail address is being protected from spambots. You need JavaScript enabled to view it

247

Beamline 11.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

1.3.2 Print 1.3.2 Print Inspection of EUV lithography masks GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 50-1000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1011 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) 7000 Endstations The SEMATECH Berkeley Actinic Inspection Tool Detector 2048 x 2048 EUV CCD Characteristics 900-1000x zoneplate microscope Spot size at sample 1-5 microns Spatial resolution 60 nm Sample format EUV Photolithography masks: 6" glass plate, multilayer coated for normal incidence reflectivity at 13.4 nm Sample preparation Cleanroom handling Sample environment 2.0 x 10-7 Torr base pressure Scientific applications EUV lithography Local contacts/ Spokespersons This e-mail address is being protected from spambots. You need JavaScript enabled to view it

248

Beamline 11.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

1.3.2 Print 1.3.2 Print Inspection of EUV lithography masks GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 50-1000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1011 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) 7000 Endstations The SEMATECH Berkeley Actinic Inspection Tool Detector 2048 x 2048 EUV CCD Characteristics 900-1000x zoneplate microscope Spot size at sample 1-5 microns Spatial resolution 60 nm Sample format EUV Photolithography masks: 6" glass plate, multilayer coated for normal incidence reflectivity at 13.4 nm Sample preparation Cleanroom handling Sample environment 2.0 x 10-7 Torr base pressure Scientific applications EUV lithography Local contacts/ Spokespersons This e-mail address is being protected from spambots. You need JavaScript enabled to view it

249

Beamline 11.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

1.3.2 Print 1.3.2 Print Inspection of EUV lithography masks GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 50-1000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1011 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) 7000 Endstations The SEMATECH Berkeley Actinic Inspection Tool Detector 2048 x 2048 EUV CCD Characteristics 900-1000x zoneplate microscope Spot size at sample 1-5 microns Spatial resolution 60 nm Sample format EUV Photolithography masks: 6" glass plate, multilayer coated for normal incidence reflectivity at 13.4 nm Sample preparation Cleanroom handling Sample environment 2.0 x 10-7 Torr base pressure Scientific applications EUV lithography Local contacts/ Spokespersons This e-mail address is being protected from spambots. You need JavaScript enabled to view it

250

Beamline 11.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

1.3.2 Print 1.3.2 Print Inspection of EUV lithography masks GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 50-1000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1011 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) 7000 Endstations The SEMATECH Berkeley Actinic Inspection Tool Detector 2048 x 2048 EUV CCD Characteristics 900-1000x zoneplate microscope Spot size at sample 1-5 microns Spatial resolution 60 nm Sample format EUV Photolithography masks: 6" glass plate, multilayer coated for normal incidence reflectivity at 13.4 nm Sample preparation Cleanroom handling Sample environment 2.0 x 10-7 Torr base pressure Scientific applications EUV lithography Local contacts/ Spokespersons This e-mail address is being protected from spambots. You need JavaScript enabled to view it

251

Beamline 11.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

1.3.2 Print 1.3.2 Print Inspection of EUV lithography masks GENERAL BEAMLINE INFORMATION Operational Yes, but not open to users Source characteristics Bend magnet Energy range 50-1000 eV Monochromator VLS-PGM Calculated flux (1.9 GeV, 400 mA) 1011 photons/s/0.01%BW at 100 eV Resolving power (E/ΔE) 7000 Endstations The SEMATECH Berkeley Actinic Inspection Tool Detector 2048 x 2048 EUV CCD Characteristics 900-1000x zoneplate microscope Spot size at sample 1-5 microns Spatial resolution 60 nm Sample format EUV Photolithography masks: 6" glass plate, multilayer coated for normal incidence reflectivity at 13.4 nm Sample preparation Cleanroom handling Sample environment 2.0 x 10-7 Torr base pressure Scientific applications EUV lithography Local contacts/ Spokespersons This e-mail address is being protected from spambots. You need JavaScript enabled to view it

252

SRI CAT Section 1 bending magnet beamline description  

SciTech Connect

This report discusses: APS bending magnet source; beamline layout; beamline optical components; beamline operation; time-resolved studies station; polarization studies station; and commissioning and operational schedule.

Srajer, G.; Rodricks, B.; Assoufid, L.; Mills, D.M.

1994-03-10T23:59:59.000Z

253

Photon Sciences | Beamlines | HXN: Hard X-ray Nanoprobe  

NLE Websites -- All DOE Office Websites (Extended Search)

HXN: Hard X-ray Nanoprobe HXN: Hard X-ray Nanoprobe Poster | Fact Sheet | Preliminary Design Report Scientific Scope The Hard X-ray Nanoprobe beamline and endstation instruments (HXN) will be designed and constructed to explore new frontiers of hard x-ray microscopy applications with the highest achievable spatial resolution. Currently the available spatial resolution for scientific applications, provided by scanning x-ray microscopes in the hard x-ray regime, is limited to ~50nm, which is still insufficient for probing the nanoscale interfacial structures critical in determining properties and functionalities of material and biological systems. The HXN beamline aims to enable x-ray experiments at spatial resolutions ranging from 10 to 30 nm with an ultimate goal of ~1 nm. Beamline Description

254

Beamline 8.3.2  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamlines (6-month cycle) Source characteristics Superbend magnet (1.9 GeV, 4.37 tesla) Energy range 6-46 keV ML mode Monochromator None or two ML or two Si(111) Flux (1.9...

255

BEAMLINE 7-2  

NLE Websites -- All DOE Office Websites (Extended Search)

7-2 7-2 CURRENT STATUS: Open SUPPORTED TECHNIQUES: X-ray scattering X-ray diffraction MAIN SCIENTIFIC DISCIPLINES: Materials / Environmental % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 20-pole, 2-Tesla Wiggler ID End Station BEAM LINE SPECIFICATIONS: energy range resolution DE/E spot size flux angular acceptance focused 4600 - 16500 eV 0.12 x 0.50 mm 0.4 mrad OPTICS: Bent cylinder, single crystal Si, Rh-coated M0 mirror Radii: 2945 m (adjustable) x 56.1 mm Mean angle of incidence: 3.81 mrad Cut off energy: 17.7 keV Magnification: 1.0 MONOCHROMATOR: LN2-cooled, sagitally focusing, double crystal Si(111) Upward reflecting Monochromator Crystal Glitch Library Crystal changes need to be scheduled and coordinated in advance with BL

256

BEAMLINE 2-2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 2 CURRENT STATUS: Open with limited support SUPPORTED TECHNIQUES: White light station MAIN SCIENTIFIC DISCIPLINES: X-ray optics characterization and development % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: Bend Magnet Side Station BEAM LINE SPECIFICATIONS: energy range resolution DE/E spot size flux angular acceptance unfocused 1000-40000 eV NA 4.0 x 8.0 mm NA 0.4 mrad OPTICS: None MONOCHROMATOR: None (white beam) ABSORPTION: 673 microns Be, 12.4 meters He, 15.2 microns C INSTRUMENTATION: X-Y stages, ion chambers, PMT DATA ACQUISITION AND ANALYSIS: SPEC For questions and issues related to SPEC, contact beam line staff or send an email to M$SPEC@ssrl.slac.stanford.edu SUPER

257

BEAMLINE 8-1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 1 CURRENT STATUS: Open SUPPORTED TECHNIQUES: Photoemission spectroscopy MAIN SCIENTIFIC DISCIPLINES: BL8-1a: Materials / Surface Chemistry BL8-1b: Materials % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: Bending magnet station (vacuum ultraviolet) BEAM LINE SPECIFICATIONS: energy range grating type resolution DE/E spot size (FWHM) flux angular acceptance focused 15 - 185 eV ~1 x 10-3 0.1 mm2 8.0 mrad OPTICS: M0 mirror: Cylindrical, SiC M1 mirror: Spherical, Fused Silica MONOCHROMATOR: 6m toroidal grating monochromator (TGM) Grating Monochromator References Monochromator Crystal Glitch Library Crystal changes need to be scheduled and coordinated in advance with BL support staff.

258

BEAMLINE 1-4  

NLE Websites -- All DOE Office Websites (Extended Search)

-4 -4 CURRENT STATUS: Open SUPPORTED TECHNIQUES: Small angle x-ray scattering MAIN SCIENTIFIC DISCIPLINES: Materials % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: Bend magnet BEAM LINE SPECIFICATIONS: energy range resolution DE/E spot size flux angular acceptance focused 7100-9000 eV 4.0 x 10-3 0.25 x 1.0 mm ~1010 2.0 mrad OPTICS: MONOCHROMATOR: Bent crystal; Si ABSORPTION: NA INSTRUMENTATION: Small/Low Angle X-ray Scattering Camera System w/CCD Detector DATA ACQUISITION AND ANALYSIS: SPEC For questions and issues related to SPEC, contact beam line staff or send an email to M$SPEC@ssrl.slac.stanford.edu RESPONSIBLE STAFF: Chris Tassone, 650-926-3124 BEAM LINE PHONE NUMBER: 650-926-5214

259

BEAMLINE 8-2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 2 CURRENT STATUS: Open SUPPORTED TECHNIQUES: X-ray absorption spectroscopy, near edge Photoemission spectroscopy MAIN SCIENTIFIC DISCIPLINES: Materials % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: Bending magnet station (soft x-ray) BEAM LINE SPECIFICATIONS: energy range grating type resolution DE/E spot size (FWHM) flux angular acceptance focused 100 - 1300 eV ~4 x 10-4 >0.1 mm2 4.0 mrad OPTICS: M0 mirror: toroidal SiC MONOCHROMATOR: 6m spherical grating monochromator (TGM) Grating Monochromator References ABSORPTION: NA INSTRUMENTATION: User Chambers on VUV Lines DATA ACQUISITION AND ANALYSIS: SPEC For questions and issues related to SPEC, contact beam line staff or send

260

BEAMLINE 2-1  

NLE Websites -- All DOE Office Websites (Extended Search)

1 1 CURRENT STATUS: Open SUPPORTED TECHNIQUES: Powder diffraction Thin film diffraction MAIN SCIENTIFIC DISCIPLINES: Materials / Environmental % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 1.3 Tesla Bend Magnet BEAM LINE SPECIFICATIONS: energy range resolution DE/E spot size flux angular acceptance focused 4000-14500 eV ~5 x 10-4 .20 x 0.45 mm 1.5 mrad OPTICS: Bent cylinder, single-crystal Si, Rh-coated mirror Radii: 2900 m (adjustable) x 52 mm Mean angle of incidence: 4.2 milliradians Cut off energy: 14.5 keV, Magnification: 1.1 MONOCHROMATOR: Si(111), Si(220) Si(400), upward reflecting, double-crystal Monochromator Crystal Glitch Library Crystal changes need to be scheduled and coordinated in advance with BL

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Mirrors for synchrotron-radiation beamlines  

Science Conference Proceedings (OSTI)

The authors consider the role of mirrors in synchrotron-radiation beamlines and discuss the optical considerations involved in their design. They discuss toroidal, spherical, elliptical, and paraboloidal mirrors in detail with particular attention to their aberration properties. They give a treatment of the sine condition and describe its role in correcting the coma of axisymmetric systems. They show in detail how coma is inevitable in single-reflection, grazing-incidence systems but correctable in two-reflection systems such as those of the Wolter type. In an appendix, they give the theory of point aberrations of reflectors of a general shape and discuss the question of correct naming of aberrations. In particular, a strict definition of coma is required if attempts at correction are to be based on the sine condition.

Howells, M.R.

1993-09-01T23:59:59.000Z

262

NIST SURF: Beamline 10: Electron beam imaging  

Science Conference Proceedings (OSTI)

Beamline 10: Electron beam imaging. Description: ... In its unperturbed state, the vertical electron beam size is quite small, in the order of a few 10 m. ...

2012-11-19T23:59:59.000Z

263

BCDA - Beamline Controls and Data Acquisition Software  

NLE Websites -- All DOE Office Websites (Extended Search)

BCDA Data Acquisition: CCD Support Data Visualization: tools used at the APS beamlines Java Channel Access: JCA Unsupported Distribution MEDM Replacement: MEDM has been the main...

264

LOMs and Beamlines | Advanced Photon Source  

NLE Websites -- All DOE Office Websites (Extended Search)

LOMs & Beamlines In designing the experiment hall, the APS benefited from the experiences of researchers who had carried out experiments at other synchrotron facilities. One lesson...

265

BEAMLINE 5-4  

NLE Websites -- All DOE Office Websites (Extended Search)

5-4 5-4 CURRENT STATUS: Open SUPPORTED TECHNIQUES: Very High Energy Resolution; Photoemission Angle-Resolved Photoelectron Spectroscopy MAIN SCIENTIFIC DISCIPLINES: Materials % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 10-period undulator, maximum field 0.61 T BEAM LINE SPECIFICATIONS: energy range grating type resolution DE/E spot size flux angular acceptance focused 7-40 eV 1700 l/mm: 7-18 eV, E/DE > 10000 2800 l/mm: 16-32 eV, E/DE> 10000 3600 l/mm: 20-40 eV, E/DE> 10000 ≥1 x 10-4 0.5 x 0.6 mm2 ~1011 >1.5 mrad OPTICS: M0: horizontal deflecting, flat, water-cooled M1: vertical focusing 10:1, elliptically cylinder M3: horizontal refocusing 1:1, cylinder M4: vertical refocusing 1:1, cylinder

266

APS 7-BM Beamline: Techniques  

NLE Websites -- All DOE Office Websites (Extended Search)

Motivation Motivation The major thrust of the 7-BM beamline is the application of synchrotron radiation tools to examine complex fluid flowfields. Two major techniques are applied: radiography and x-ray fluorescence spectroscopy. While optical techniques are often ideally suited to the study of fluid flowfields, there are certain flowfields for which optical diagnostics have significant challenges. These include: Multiphase flows: Visible light interacts strongly with phase boundaries. This leads to strong refraction, scattering, and attenuation of light. These effects hinder quantitative measurements of dense multiphase flowfields. Opaque media. Flows with strong refractive effects. Luminous flames: The strong light emission from sooting flames can hinder certain optical diagnostics.

267

APS Beamline 6-ID-D  

NLE Websites -- All DOE Office Websites (Extended Search)

MM-Group Home MM-Group Home MMG Advisory Committees 6-ID-D Home Recent Publications Beamline Info Optics Instrumentation Software User Info Beamline 6-ID-D Beamline 6-ID-D is operated by the Magnetic Materials Group in the X-ray Science Division (XSD) of the Advanced Photon Source. This is a high energy (50 - 130 keV) beamline used for structural studies primarily on single crystal materials. Recent Research Highlights LuFeO Unlikely route to ferroelectricity May 16, 2012 A new type of ferroelectric, LuO2Fe4, has been investigated at the APS by a research team from Julich research center. XAS & XMCD studies on beamline 4-ID-C determined the Fe magnetism and valence, while single crystal x-ray scattering measurements at 6-ID-B & 6-ID-D probed the associated structural and charge ordering.

268

APS Beamline 6-ID-D  

NLE Websites -- All DOE Office Websites (Extended Search)

D Home D Home Recent Publications Beamline Info Optics Instrumentation Software User Info Beamline 6-ID-D Beamline 6-ID-D is operated by the Magnetic Materials Group in the X-ray Science Division (XSD) of the Advanced Photon Source. This is a high energy (50 - 130 keV) beamline used for structural studies primarily on single crystal materials. Recent Research Highlights A New Family of Quasicrystals A New Family of Quasicrystals June 24, 2013 Scientists from the U.S. Department of Energy's Ames Laboratory and Iowa State University have used the high energy x-rays available on beamline 6-ID-D, to confirm the structure of the only known magnetic rare earth icosahedral binary quasicrystals. Contacts: Alan Goldman & Paul Canfield - Iowa State Univ. & Ames Lab Local Contacts:

269

APS 7-BM Beamline: 7-BM Home  

NLE Websites -- All DOE Office Websites (Extended Search)

Overview of the 7-BM beamline Overview of the 7-BM beamline The 7-BM beamline is dedicated to time-resolved measurements of complex fluid flowfields using x-ray radiography and fluorescence spectroscopy. Funding for the final commissioning of 7-BM was provided by the DOE Office of Energy Efficiency and Renewable Energy. Commissioning was completed at the end of FY2012. The beamline is currently operated by the X-Ray Science Division of the APS. Major Areas of Research Fuel sprays from automotive fuel injectors, both diesel and gasoline. See more on the X-Ray Fuel Spray web page from Argonne's Energy Systems Division. Sprays for air-breathing propulsion. Fuel injection for rocket injectors. Gas-phase fuel injection and mixing. Beamline Performance Total flux: 4 x 1011 ph/s at 8 keV Energy range: 5.5 - 11 keV, 1.4% ΔE/E

270

APS Beamline Questionnaire Form | Advanced Photon Source  

NLE Websites -- All DOE Office Websites (Extended Search)

APS Beamline Motor Drive Questionnaire Form APS Beamline Motor Drive Questionnaire Form * indicates required field Please send a separate email to Thomas Barkalow with an attached beamline drawing or sketch showing where the groups are located and the distances they are apart. First Name*: Middle Initial/Name: Last Name*: Beamline Designation*: What is the total number of driver units with makes and models?: How are driver units grouped together and each group's location within the beamline?: What number of driver units are in use simultaneously for each group?: What is the maximum amperage setting actually used for each unit?: What is the number of groups in use simultaneously and which groups are they?: Verification: We need to make sure you are a human. Please solve the challenge below, and click the I'm a Human button to get a confirmation code. To make this

271

Wiggler-base Hard X-ray Spectroscopy Beamline at CLS  

Science Conference Proceedings (OSTI)

The CLS 06ID-1 Hard X-ray Micro-Analysis Beamline (HXMA) is a general purpose hard X-ray spectroscopy beamline (5 to 40 keV) designed to serve users in XAFS, diffraction and microprobe communities. The beamline uses the synchrotron radiation from a superconducting wiggler. The primary beamline optics include a 1.2 m water-cooled silicon collimating mirror (separate Rh and Pt coating stripes), a liquid nitrogen cooled double crystal monochromator (Kohzu CMJ-1) housing two crystal pairs (Si 111 and 220), and a 1.15 m long water-cooled silicon toroidal focusing mirror (separate Rh and Pt coating stripes). All mirrors are equipped with dynamical meridian benders. The experimental hutch hosts three experimental setups for XAFS, diffraction and microprobe, respectively. Primary design considerations and some commissioning results are discussed.

Jiang, D. T. [Canadian Light Source, University of Saskatchewan, Saskatoon, SK (Canada); Department of Physics, University of Guelph, Guelph ON N1G 2W1 (Canada); Chen, N. [Canadian Light Source, University of Saskatchewan, Saskatoon, SK (Canada); Geological Sciences Department, University of Saskachewan, Saskatoon, SK (Canada); Sheng, W. [Canadian Light Source, University of Saskatchewan, Saskatoon, SK (Canada)

2007-01-19T23:59:59.000Z

272

Diagnostic X-Multi-Axis Beamline  

SciTech Connect

Tomographic reconstruction of explosive events require time resolved multipal lines of sight. Considered here is a four (or eight) line of sight beam layout for a nominal 20 MeV 2000 Ampere 2 microsecond electron beam for generation of x-rays 0.9 to 5 meters from a given point, the ''firing point''. The requirement of a millimeter spatial x-ray source requires that the electron beam be delivered to the converter targets with sub-millimeter precision independent of small variations in beam energy and initial conditions. The 2 usec electron beam pulse allows for four bursts in each line, separated in time by about 500 microseconds. Each burst is divided by a electro-magnetic kicker into four (or eight) pulses, one for each beamline. The arrival time of the four (or eight) beam pulses at the x-ray target can be adjusted by the kicker timing and the sequence that the beams of each burst are switched into the different beamlines. There exists a simple conceptual path from a four beamline to a eight beamline upgrade. The eight line beamline is built up from seven unique types of sub-systems or ''blocks''. The beamline consists of 22 of these functional blocks and contains a total of 455 individual magnets, figure 1. The 22 blocks are inter-connected by a total of 30 straight line inter-block sections (IBS). Beamlines 1-4 are built from 12 blocks with conceptual layout structure shown in figure 2. Beamlines 5-8 are built with an additional 10 blocks with conceptual layout structure shown in figure 3. This beamline can be thought of as looking like a lollipop consisting of a 42 meter long stick leading to a 60 by 70 meter rectangular candy blob consisting of the eight lines of sight. The accelerator providing the electron beam is at the end of the stick and the firing point is at the center of the blob. The design allows for a two stage implementation. Beamlines 1-3 can be installed to provide a tomographic azimuthal resolution of 45 degrees. An upgrade can later be made by adding beamlines 5-8 azimuthally indexed so as to provide an azimuthal resolution of 22.5 degrees. All eight beamlines point down by 10 degrees (pitch). The x-ray converter target can be located along each beamline anywhere between 0 to 5 meters from the firing point. An example of inter-facing the Diagnostic X facility with the Darht II accelerator located at LANL will be given.

Paul, A C

2000-04-05T23:59:59.000Z

273

APS Beamline Station Operational Limits Information Page  

NLE Websites -- All DOE Office Websites (Extended Search)

Information Listed below are the conditions for a beamline to be accepting beam for CommissioningOperations. These conditions have been placed by the AOD ADD for Operations based...

274

ALS Beamline Design Requirements - Revision 1  

E-Print Network (OSTI)

Source Photon Beam LinesBNL/NSLS XI Beamline Mirror SystemSynchrotron Light Source (NSLS) at Brookhaven NationalMay 1996. ' R Stefan, NSLS-BNL, personal communication.

Heimann, Phil

2010-01-01T23:59:59.000Z

275

Experiment Hall & Beamline | Advanced Photon Source  

NLE Websites -- All DOE Office Websites (Extended Search)

Experiment Hall & Beamlines The ratchet-shaped radiation-shielding wall between the APS storage ring and the experiment hall serves as a line of demarcation. Thirty-five "sectors"...

276

CAT Guide and Beamline Directory. A key to APS Collaborative Access Teams  

SciTech Connect

The Advanced Photon Source (APS), a national user facility for synchrotrons radiation research, is located at Argonne National Laboratory, approximately 25 miles southwest of Chicago, Illinois. The APS is considered a third-generation synchrotrons radiation facility (specifically designed to accommodate insertion devices to serve as radiation sources) and is one of three such facilities in the world. Currently, it is the most brilliant source in the United States for research in such diverse fields as biology, medicine, materials science, chemistry, geology, agriculture and soil science, physics, and manufacturing technology. Researchers use the APS either as members of Collaborative Access Teams (CATS) or as Independent Investigators (IIs). CATS are responsible for designing, building, and operating beamlines in one or more sectors, each sector consisting of an insertion-device (ID) beamline and a bending-magnet (BM) beamline. Each beamline is designed to accommodate a specific type of research program(s) and is optimized accordingly. CAT members are entitled to use 75% of the available beam time to pursue CAT research goals. The remaining 25% of the available beam time must be made available to IIs. This document was written to help prospective IIs determine which beamlines are suitable for their specific experiments.

1999-07-08T23:59:59.000Z

277

Beamline Safety Design Review Steering Committee Charter  

NLE Websites -- All DOE Office Websites (Extended Search)

Meeting Minutes internal link Meeting Minutes internal link Reviews internal link Beamline Safety Design Review Steering Committee (BSDRSC) 1. Purpose The Beamline Safety Design Review Steering Committee (BSDRSC) oversees the review of all safety aspects related to beamline and critical component design, regardless of who generated the design, and includes facility operational issues when reviewing non-APS generated designs. 2. Membership Members appointed by the APS Division Directors will be comprised of a pre-selected standing committee with membership chosen by function. The following functions will be included: AES User Technical Interface (Committee Chair) AES Technical Operations Specialist APS Electrical / Electronics Technical Representative AES QA Engineering Specialist APS Radiation Safety Shielding Committee Chair

278

1-ID: Sector 1, Insertion Device Beamline  

NLE Websites -- All DOE Office Websites (Extended Search)

1-ID beamline schematic 1-ID beamline schematic ID on-axis brilliance values 1-ID - Sector 1, Insertion Device Beamline Responsible Scientists Jon Almer, phone: (630) 252-1049, e-mail: almer@aps.anl.gov Sarvjit Shastri, phone: (630) 252-0129, e-mail: shastri@aps.anl.gov John Okasinski, phone: (630) 252-0162, e-mail: okasinski@aps.anl.gov Peter Kenesei, phone: (630) 252-0133, e-mail: kenesei@aps.anl.gov Scientific Programs Coupled high-energy SAXS/WAXS studies (HE-SAXS/WAXS) High-energy diffraction microscopy (HEDM) Single-grain studies Stress/strain/texture studies Pair-distribution function (PDF) measurements High-energy fluorescence Source Characteristics Upstream insertion device: APS Undulator A No. of Poles 72 Undulator Period 3.3 cm Device Length 2.4 m Minimum Gap 11 mm Downstream insertion device

279

NIST SURF Beamline 3: Facility for Irradiance Calibration ...  

Science Conference Proceedings (OSTI)

... Beamline 3 is home to the Facility for Irradiance Calibration Using ... Source of Uncertainty, Nominal Value, Relative Uncertainty, Sensitivity Coefficient, ...

2012-11-19T23:59:59.000Z

280

The Phase I MX Beamlines at Diamond Light Source  

Science Conference Proceedings (OSTI)

Three beamlines dedicated to macromolecular crystallography, I02, I03 and I04 at Diamond Light Source are presented. These beamlines formed the life science component of Phase 1 of Diamond Light Source. The article provides details of the design and the current status of the beamlines.

Duke, E. M. H.; Evans, G.; Flaig, R.; Hall, D. R.; Latchem, M.; McAuley, K. E.; Sandy, D. J.; Sorensen, T. L-M.; Waterman, D.; Johnson, L. N. [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxon. OX11 0DE (United Kingdom)

2010-06-23T23:59:59.000Z

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

Biology @WIPP Life Begins at 250,000,000 Years WIPP's underground isn't just suited for physics experiments aiming to unlock the mysteries of the Universe, it is also a perfect...

282

Beamline Phone Numbers| Advanced Photon Source  

NLE Websites -- All DOE Office Websites (Extended Search)

Interactive Map Interactive Map Beamlines Map Beamlines Directory Techniques Directory Sectors Directory Beamline Phone Numbers Status and Schedule Beamline Phone Numbers From on-site, dial 2, then a number listed below. From off-site, dial 630-252 and a number listed below. Sector 1 1-BM-A: 1701 1-BM-C: 5468 1-ID: 1801 Sector 2 2-BM: 1702 2-ID-B: 1628 2-ID-D: 1802 2-ID-E: 3711 Sector 3 3-ID: 1803 Sector 4 4-ID-C: 1704 4-ID-D: 1804 Sector 5 5-BM: 1705 5-ID: 1805 Sector 6 6-ID-B: 1806 6-ID-C: 1406 6-ID-D: 1606 Sector 7 7-ID-B: 1607 7-ID-C: 1707 7-ID-D: 1807 7-ID-E: 1207 Sector 8 8-ID-E: 1908 8-ID-I: 1808 Sector 9 9-BM-B: 1709 9-ID-B: 0349 9-ID-C: 1809 Column 95: 4705 Sector 10 10-BM-B: 6792 10-ID-B: 1710 Sector 11 11-BM-B: 5877 11-ID-B: 1711 11-ID-C: 1711 11-ID-D: 2162 Laser lab: 0379 Sector 12 12-BM-B: 0378 12-ID-B,C: 1712

283

Biologic  

E-Print Network (OSTI)

In this paper we explore the boundary between biology and the study of formal systems (logic). In the end, we arrive at a summary formalism, a chapter in "boundary mathematics" where there are not only containers but also extainers >biologic what boolean algebra is to classical logic. We show how this formalism encompasses significant parts of the logic of DNA replication, the Dirac formalism for quantum mechanics, formalisms for protein folding and the basic structure of the Temperley Lieb algebra at the foundations of topological invariants of knots and links.

Louis H. Kauffman

2002-04-02T23:59:59.000Z

284

General User Proposal Scores  

NLE Websites -- All DOE Office Websites (Extended Search)

General User Proposal Scores General User Proposal Scores General User Proposal Scores Print Tuesday, 01 June 2010 10:34 Scoring Proposals are scored on a scale of 1 to 5, with 1 being the best score and 5 the worst. Reviewers are requested to use the following ranking schema: Must do High Priority Medium Priority Low priority Don't do Beam time is assigned based on each proposal's score in relation to all other proposals for a given beamline. For beamlines where beamtime requests exceed available beamtime, a cutoff score is assigned after which no beam time is allocated. proposal scores Beam Time Cutoff Scores for the Current Cycle The table below lists the percent of beam time shifts allocated/requested for each beamline, and the cutoff scores, below which no beam time was assigned.

285

On Line Beamline Commissioning Activity Approval Form  

NLE Websites -- All DOE Office Websites (Extended Search)

Commissioning Activity Approval Form Commissioning Activity Approval Form This form is to be filled by the Commissioning Activity Team Leader. No beamline commissioning activities will be allowed to run without a properly completed, approved, and posting of this commissioning approval form. You will be notified by e-mail upon approval. Sector Beamline Expected Start Date Expected Duration 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 BM ID ( Give a Unit) Activity Description( Give only a brief description) Commissioning Team Members First and Last Name Affiliation Phone Number 1. 2. 3. 4. 5. 6. Special Safety Concerns Commissioning Activity Team Leader Name E-Mail Address Submit Commissioning Activity Approval Form Clear all Fields and start All over again!!!

286

1993 CAT workshop on beamline optical designs  

SciTech Connect

An Advanced Photon Source (APS) Collaborative Access Team (CAT) Workshop on Beamline Optical Designs was held at Argonne National Laboratory on July 26--27, 1993. The goal of this workshop was to bring together experts from various synchrotron sources to provide status reports on crystal, reflecting, and polarizing optics as a baseline for discussions of issues facing optical designers for CAT beamlines at the APS. Speakers from the European Synchrotron Radiation Facility (ESRF), the University of Chicago, the National Synchrotron Light Source, and the University of Manchester (England) described single- and double-crystal monochromators, mirrors, glass capillaries, and polarizing optics. Following these presentations, the 90 participants divided into three working groups: Crystal Optics Design, Reflecting Optics, and Optics for Polarization Studies. This volume contains copies of the presentation materials from all speakers, summaries of the three working groups, and a ``catalog`` of various monochromator designs.

1993-11-01T23:59:59.000Z

287

Upgrade of the Proton West secondary beamline  

SciTech Connect

As originally designed and operated, protons entering PW6 were steered by a series of EPB dipoles into a single interaction length beryllium target, some 43 feet from the enclosure wall. Ensuing secondary beams, either p{sup +}/{pi}{sup +} or p{sup -}/{pi}{sup -}, were collected by a string of quadrupoles following the target, steered westward, away from the Proton Center line, through PW6 and PW7, and ultimately focussed on experiment production targets located within the large PW8 hall. Around the Spring of 1988 it was decided to upgrade the existing Proton West secondary beamline to allow for transport of a primary proton beam, anticipated to be either 800 or 900 GeV/c, through PW8. This upgrade project, which is now nearing completion, was largely motivated by the then recent approval of E-771, a hadronic beauty production experiment located in PW8. E-771 represents the third in a series of experiments for the large-acceptance dimuon spectrometer presently located at the end of the Proton West beamline. This Technical Memo is a summary of the upgrade --- an explanation of the underlying strategy and a documentation of the final locations of the secondary beamline elements. 6 refs., 2 figs., 2 tabs.

Spiegel, L.

1989-10-10T23:59:59.000Z

288

Photon Sciences Directorate | 2010 Annual Report | Project Beamlines  

NLE Websites -- All DOE Office Websites (Extended Search)

mature to begin long-lead-time procurements of major beamline systems, such as radiation enclosures and optical systems. Motion controllers are being tested and...

289

TGM-to-SGM conversion at NSLS beamline U7A: Recyclying of beamline components  

Science Conference Proceedings (OSTI)

The U7A bending magnet toroidal grating monochromator (TGM) beamline has been converted into a spherical grating monochromator (SGM) type, without constructing any new vacuum components. That is, the mirror, slit, and grating chambers have been recycled. The inherited optical arrangement and the recycling concept prevented the use of {open_quote}{open_quote}standard{close_quote}{close_quote} SGM Kirkpatrick-Baez collecting and focusing mirrors at the front end. We show that this modification is not a serious detriment to the optical properties of the resulting beamline. Specifically, the resolution is completely unaffected and the throughput is approximately 2/3 of the {open_quote}{open_quote}standard{close_quote}{close_quote} SGM value. The flux and photon energy resolution of the U7A beamline throughout its 200{endash}1000 eV operating photon energy range will be presented. Three end stations are being constructed for this beamline, featuring soft x-ray absorption and photoemission chambers optimized for operation in the carbon K-, oxygen K-, and transition metal L-edge ranges. Two of these end stations will be preceded by refocusing mirrors that will focus the soft x-rays to {lt}1 mm spot size onto their samples. {copyright} {ital 1996 American Institute of Physics.}

Hulbert, S.L.; Dong, Q. [NSLS, Brookhaven National Laboratory, Bldg. 725D, Upton, NY 11973-5000 (United States)

1996-09-01T23:59:59.000Z

290

APS beamline standard components handbook. Version 1.1  

SciTech Connect

It is clear that most Advanced Photon Source (APS) Collaborative Access Team (CAT) members would like to concentrate on designing specialized equipment related to their scientific programs rather than on routine or standard beamline components. Thus, an effort is in progress at the APS to identify standard and modular components of APS beamlines. Identifying standard components is a nontrivial task because these components should support diverse beamline objectives. To assist with this effort, the APS has obtained advice and help from a Beamline Standardization and Modularization Committee consisting of experts in beamline design, construction, and operation. The staff of the Experimental Facilities Division identified various components thought to be standard items for beamlines, regardless of the specific scientific objective of a particular beamline. A generic beamline layout formed the basis for this identification. This layout is based on a double-crystal monochromator as the first optical element, with the possibility of other elements to follow. Pre-engineering designs were then made of the identified standard components. The Beamline Standardization and Modularization Committee has reviewed these designs and provided very useful input regarding the specifications of these components. We realize that there will be other configurations that may require special or modified components. This Handbook in its current version (1.1) contains descriptions, specifications, and pre-engineering design drawings of these standard components. In the future, the APS plans to add engineering drawings of identified standard beamline components. Use of standard components should result in major cost reductions for CATs in the areas of beamline design and construction.

Kuzay, T.M.

1992-01-01T23:59:59.000Z

291

SIBYLS - A SAXS and protein crystallography beamline at the ALS  

E-Print Network (OSTI)

Beamline at the ALS C.Trame*, A.A.MacDowell*, R.S.Celestre*,recently installed at the ALS that allows for a hard x-rayAdvanced Light Source (ALS) ring (1.9 GeV). The beamline is

2003-01-01T23:59:59.000Z

292

Diagnostics Beamline for the SRF Gun Project  

Science Conference Proceedings (OSTI)

A superconducting radio-frequency photo electron injector (SRF gun) is currently under construction by a collaboration of BESSY, DESY, FZR and MBI. The project aims at the design and setup of a CW SRF gun including a diagnostics beamline for the ELBE FEL and to address R&D issues on low emittance injectors for future light sources such as the BESSY FEL. Of critical importance for the injector performance is the control of the electron beam parameters. For this reason a compact diagnostics beamline is under development serving a multitude of operation settings ranging from low-charge (77pC), low-emittance (1 mm mrad) mode to high-charge (2.5nC) operation of the gun. For these operation modes beam dynamics simulations are resulting in boundary conditions for the beam instrumentation. Proven and mature technology is projected wherever possible, for example for current and beam position monitoring. The layout of the beam profile and emittance measurement systems is described. For the bunch length, which varies between 5 ps and 50 ps, two schemes using electro-optical sampling and Cherenkov radiation are detailed. The beam energy and energy spread is measured with a 180-degree spectrometer.

T. Kamps; V. Durr; K. Goldammer; D. Kramer; P. Kuske; J. Kuszynski; D. Lipka; F. Marhauser; T. Quast; D. Richter; U. Lehnert; P. Michel; J. Teichert; P. Evtushenko; I. Will

2005-08-22T23:59:59.000Z

293

G4beamline Particle Tracking in Matter Dominated Beam Lines  

Science Conference Proceedings (OSTI)

The G4beamline program is a useful and steadily improving tool to quickly and easily model beam lines and experimental equipment without user programming. It has both graphical and command-line user interfaces. Unlike most accelerator physics codes, it easily handles a wide range of materials and fields, being particularly well suited for the study of muon and neutrino facilities. As it is based on the Geant4 toolkit, G4beamline includes most of what is known about the interactions of particles with matter. We are continuing the development of G4beamline to facilitate its use by a larger set of beam line and accelerator developers. A major new feature is the calculation of space-charge effects. G4beamline is open source and freely available at http://g4beamline.muonsinc.com

T.J. Roberts, K.B. Beard, S. Ahmed, D. Huang, D.M. Kaplan

2011-03-01T23:59:59.000Z

294

BEAMLINE 11-3 Materials Diffraction  

NLE Websites -- All DOE Office Websites (Extended Search)

3 3 CURRENT STATUS: Open SUPPORTED TECHNIQUES: X-ray scattering Thin film diffraction MAIN SCIENTIFIC DISCIPLINES: Materials / Environmental / Biology % TIME GENERAL USE: 100% SCHEDULING: Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 26-pole, 2.0-Tesla ID Side Station BEAM LINE SPECIFICATIONS: energy range resolution DE/E spot size flux angular acceptance focused 12735 eV ~5 x 10-4 3.1 x 0.15 mm Usable 0.15 x 0.15 mm OPTICS: Single-crystal Si, Rh-coated - vertically focusing mirror MONOCHROMATOR: Bent cube-root I_beam Si(311), Side deflecting Monochromator Crystal Glitch Library Crystal changes need to be scheduled and coordinated in advance with BL support staff. ABSORPTION: INSTRUMENTATION: Standard detector: MAR345 Imaging Plate - 345 mm

295

Commissioning of a microprobe-XRF beamline (BL-16) on Indus-2 synchrotron source  

Science Conference Proceedings (OSTI)

We report commissioning of the microprobe-XRF beamline on Indus-2 synchrotron source. The beamline has been recently made operational and is now open for the user's experiments. The beamline comprises of Si(111) double crystal monochromator and Kirkpatrick-Baez focusing optics. The beamline covers wide photon energy range of 4 - 20 keV using both collimated and micro-focused beam modes. The design details and the first commissioning results obtained using this beamline are presented.

Tiwari, M. K.; Gupta, P.; Sinha, A. K.; Garg, C. K.; Singh, A. K.; Kane, S. R.; Garg, S. R.; Lodha, G. S. [Indus Synchrotron Utilisation Division, Raja Ramanna Centre for Advanced Technology, Indore-452013 (India)

2012-06-05T23:59:59.000Z

296

Noise reduction efforts for the ALS infrared beamlines  

E-Print Network (OSTI)

is being commissioned at the ALS that should help quietalso has links to the main ALS Infrared Website, where PDFsNoise reduction efforts for the ALS infrared beamlines Tom

2003-01-01T23:59:59.000Z

297

The monochromator beamline at FLASH: performance, capabilities and upgrade plans  

E-Print Network (OSTI)

The monochromator beamline at the FLASH facility at DESY is the worldwide first XUV monochromator beamline operational on a free electron laser (FEL)source. Being a single-user machine, FLASH demands a high flexibility of the instrumentation to fulfil the needs of diverse experiments performed by a multidisciplinary user community. Thus, the beamline has not only been used for high-resolution spectroscopy that it was originally designed for, but also for pump-probe experiments controlling the temporal-spectral properties at moderate resolution, and as a filter for high harmonics of the FEL at very low resolution. The present performance and capabilities of the beamline are discussed with emphasis on particularities arising from the nature of the FEL source, and current developments are presented aiming to enhance its capabilities for accommodating a wide variety of experiments.

Gerasimova, Natalia; Feldhaus, Josef; 10.1080/09500340.2011.588344

2013-01-01T23:59:59.000Z

298

Photon Sciences | Beamlines | CHX: Coherent Hard X-ray Scattering...  

NLE Websites -- All DOE Office Websites (Extended Search)

exceeding, for a photon energy near E8 keV, 1021 phsmrad2mm20.1 % bw (more than one order of magnitude higher than that of the Advanced Photon Source), the CHX beamline will...

299

Status of the LBNE Neutrino Beamline  

SciTech Connect

The Long Baseline Neutrino Experiment (LBNE) will utilize a neutrino beamline facility located at Fermilab to carry out a compelling research program in neutrino physics. The facility will aim a beam of neutrinos toward a detector placed at the Homestake Mine in South Dakota. The neutrinos are produced in a three-step process. First, protons from the Main Injector (60-120 GeV) hit a solid target and produce mesons. Then, the charged mesons are focused by a set of focusing horns into the decay pipe, towards the far detector. Finally, the mesons that enter the decay pipe decay into neutrinos. The parameters of the facility were determined taking into account several factors including the physics goals, the Monte Carlo modeling of the facility, spacial and radiological constraints and the experience gained by operating the NuMI facility at Fermilab. The initial beam power is expected to be {approx}700 kW, however some of the parameters were chosen to be able to deal with a beam power of 2.3 MW. We discuss here the status of the conceptual design and the associated challenges.

Papadimitriou, Vaia; /Fermilab

2011-12-01T23:59:59.000Z

300

U2B Beamline | Photon Sciences | Brookhaven National Laboratory  

NLE Websites -- All DOE Office Websites (Extended Search)

BNL People BNL People Photon SciencesInfrared Programs PS Home Infrared Home Beamlines U2A U2B U4IR U10A U10B U12IR Publications User Info Useful Sites Beamline U2B Home Publications Equipment Schedule Beamtime Instrument Spectrometer endstation: Thermo Nicolet Magna 860 Step-Scan FTIR and Continuum IR microscope Frequency Range (cm-1): 500 - 4000 Spectral resolution (cm-1): 4.0 Spatial resolution: diffraction-limit (i.e. ~ 3 to 10 microns) Brightness (compared to a black body): 100x to 1000x Smallest practical targeting aperture size: 3 microns square Beamline angular acceptance: (milliradians): 40H x 40V (100% vertical collection down to 240 cm-1) Optical Configuration A two-mirror system (M1 and M2) collects and re-images the synchrotron infrared source at a point just outside of the storage ring's UHV. M1 is a

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

ACDOS1: A COMPUTER CODE TO CALCULATE DOSE RATES FROM NEUTRON ACTIVATION OF NEUTRAL BEAMLINES AND OTHER FUSION REACTOR COMPONENTS  

E-Print Network (OSTI)

BEAMLINES AND OTHER FUSION--REACTOR COMPONENTS Gregory S.Beamlines and Other Fusion-Reactor Compon ents By Gregoryin the Tokamak Fusion Test Reactor Test Cell", Nucl.

Keney, G.S.

2010-01-01T23:59:59.000Z

302

Temperature and TimeResolved XRay Powder Diffraction X14A EERE sponsored PRT beamline  

E-Print Network (OSTI)

Temperature and TimeResolved XRay Powder Diffraction X14A EERE sponsored PRT beamline Objective, in ambience or with gas flow Capabilities: X14A, EERE-sponsored PRT beamline · High photon flux: typically 9x

Homes, Christopher C.

303

Final Technical Report on STTR Project DE-FG02-06ER86281 Particle Tracking in Matter-Dominated Beam Lines (G4beamline)  

SciTech Connect

This project has been for software development of the G4beamline [1] program, which is a particle-tracking simulation program based on the Geant4 toolkit [2], optimized for beam lines. This program can perform more realistic simulations than most alternatives, while being significantly easier to use by physicists. This project has fostered the general acceptance of G4beamline within the muon community, and has assisted in expanding its role outside that community. During this project, the G4beamline user community has grown from about a half-dozen users to more than 200 users around the world. This project also validated our business decision to keep G4beamline an open-source program, judging that an STTR project would provide more development resources than would marketing and selling the program. G4beamline is freely available to the physics community, and has been well validated against experiments and other codes within its domain. Muons, Inc. continues to support and develop the program, and a major part of the company??s continued success and growth is directly related to our expertise in applying this program to interesting applications.

Muons, Inc.

2011-05-19T23:59:59.000Z

304

APS beamline standard components handbook, Version 1. 3  

SciTech Connect

This Handbook in its current version (1.3) contains descriptions, specifications, and preliminary engineering design drawings for many of the standard components. The design status and schedules have been provided wherever possible. In the near future, the APS plans to update engineering drawings of identified standard beamline components and complete the Handbook. The completed version of this Handbook will become available to both the CATs and potential vendors. Use of standard components should result in major cost reductions for CATs in the areas of beamline design and construction.

Hahn, U.; Shu, D.; Kuzay, T.M.

1993-02-01T23:59:59.000Z

305

Commissioning of soft and deep X-ray lithography beamline on Indus-2  

Science Conference Proceedings (OSTI)

Soft and Deep x-ray lithography (SDXRL) beamline is commissioned on Indus-2. The beamline can be operated between 1.5 to 20 keV and in white beam mode. Beamline consists of two x-ray mirrors, slits, Be-windows, beam diagnostics and filters assemblies and radiation safety systems. A custom built X-ray scanner is used to create 3-D high aspect ratio micro structures. The paper reports the commissioning results of this beamline.

Dhamgaye, V. P.; Sankar, B. Gowri; Garg, C. K.; Lodha, G. S. [Indus Synchrotrons Utilisation Division, Raja Ramanna Centre for Advanced Technology, Indore (India)

2012-06-05T23:59:59.000Z

306

Characterization of a mini-multileaf collimator in a proton beamline  

Science Conference Proceedings (OSTI)

A mini-multileaf collimator (MMLC) was mounted as a field shaping collimator in a proton beamline at the Massachusetts General Hospital. The purpose is to evaluate the device's dosimetric and mechanical properties for the use in a proton beamline. For this evaluation, the authors compared MMLC and brass aperture shaped dose distributions with regard to lateral and depth dose properties. The lateral fall off is generally broader with the MMLC, with difference varying with proton range from 0.2 to 1.2 mm. Central axis depth dose curves did not show a difference in peak-to-entrance ratio, peak width, distal fall off, or range. Two-dimensional dose distributions to investigate the conformity of MMLC shaped doses show that the physical leaf width of {approx_equal}2.5 mm does not have a significant impact. All differences seen in dose distribution shaped by the MMLC versus brass apertures were shown to be clinically insignificant. Measured neutron doses of 0.03-0.13 mSv/Gy for a closed brass beam block (depending on range) are very low compared to the previously published data. Irradiation of the tungsten MMLC, however, produced 1.5-1.8 times more neutrons than brass apertures. Exposure of the staff resulting from activation of the device is below regulatory limits. The measurements established an equivalency between aperture and MMLC shaped dose distributions.

Daartz, J.; Bangert, M.; Bussiere, M. R.; Engelsman, M.; Kooy, H. M. [Department of Radiation Oncology, Francis H. Burr Proton Therapy Center, Massachusetts General Hospital, Boston, Massachusetts 02114 and Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg 69120 (Germany); Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg 69120 (Germany); Department of Radiation Oncology, Francis H. Burr Proton Therapy Center, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States)

2009-05-15T23:59:59.000Z

307

The Diamond Beamline Controls and Data Acquisition Software Architecture  

Science Conference Proceedings (OSTI)

The software for the Diamond Light Source beamlines[1] is based on two complementary software frameworks: low level control is provided by the Experimental Physics and Industrial Control System (EPICS) framework[2][3] and the high level user interface is provided by the Java based Generic Data Acquisition or GDA[4][5]. EPICS provides a widely used

N. Rees; Diamond Controls Group; Diamond Data Acquisition Group

2010-01-01T23:59:59.000Z

308

Beamline standard component designs for the Advanced Photon Source  

SciTech Connect

The Advanced Photon Source (APS) has initiated a design standardization and modularization activity for the APS synchrotron radiation beamline components. These standard components are included in components library, sub-components library and experimental station library. This paper briefly describes these standard components using both technical specifications and side view drawings.

Shu, D.; Barraza, J.; Brite, C.; Chang, J.; Sanchez, T.; Tcheskidov, V.; Kuzay, T.M.

1994-12-01T23:59:59.000Z

309

ADLIB: A simple database framework for beamline codes  

SciTech Connect

There are many well developed codes available for beamline design and analysis. A significant fraction of each of these codes is devoted to processing its own unique input language for describing the problem. None of these large, complex, and powerful codes does everything. Adding a new bit of specialized physics can be a difficult task whose successful completion makes the code even larger and more complex. This paper describes an attempt to move in the opposite direction, toward a family of small, simple, single purpose physics and utility modules, linked by an open, portable, public domain database framework. These small specialized physics codes begin with the beamline parameters already loaded in the database, and accessible via the handful of subroutines that constitute ADLIB. Such codes are easier to write, and inherently organized in a manner suitable for incorporation in model based control system algorithms. Examples include programs for analyzing beamline misalignment sensitivities, for simulating and fitting beam steering data, and for translating among MARYLIE, TRANSPORT, and TRACE3D formats.

Mottershead, C.T.

1993-01-01T23:59:59.000Z

310

ADLIB: A simple database framework for beamline codes  

SciTech Connect

There are many well developed codes available for beamline design and analysis. A significant fraction of each of these codes is devoted to processing its own unique input language for describing the problem. None of these large, complex, and powerful codes does everything. Adding a new bit of specialized physics can be a difficult task whose successful completion makes the code even larger and more complex. This paper describes an attempt to move in the opposite direction, toward a family of small, simple, single purpose physics and utility modules, linked by an open, portable, public domain database framework. These small specialized physics codes begin with the beamline parameters already loaded in the database, and accessible via the handful of subroutines that constitute ADLIB. Such codes are easier to write, and inherently organized in a manner suitable for incorporation in model based control system algorithms. Examples include programs for analyzing beamline misalignment sensitivities, for simulating and fitting beam steering data, and for translating among MARYLIE, TRANSPORT, and TRACE3D formats.

Mottershead, C.T.

1993-03-01T23:59:59.000Z

311

10 Questions for a Beamline Scientist: Apurva Mehta | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

10 Questions for a Beamline Scientist: Apurva Mehta 10 Questions for a Beamline Scientist: Apurva Mehta 10 Questions for a Beamline Scientist: Apurva Mehta November 4, 2011 - 1:02pm Addthis Apurva Mehta | Image courtesy of SLAC Apurva Mehta | Image courtesy of SLAC Niketa Kumar Niketa Kumar Public Affairs Specialist, Office of Public Affairs "It was exhilarating when we found a novel solution and the instrument evolved." Apurva Mehta, Beamline Scientist Fifteen years ago, SLAC National Accelerator Laboratory (SLAC) scientist Apurva Mehta volunteered to help a friend build beamline parts at the Stanford Synchrotron Radiation Lightsource (SSRL). Today, he's "still mucking around with beamlines."
 
In the latest 10 Questions, Dr. Mehta shares how he landed at SLAC and his adventures in a wide range of projects, from advanced semiconductors to

312

Photon Sciences Directorate | 2010 Annual Report | Beamline & Optics R&D:  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamline & Optics R&D: Enhancing Tools at NSLS, NSLS-II Beamline & Optics R&D: Enhancing Tools at NSLS, NSLS-II Qun Shen "Synchrotron sources have quickly become an essential tool for a wide spectrum of research. All the action takes place at beamlines, each one consisting of a suite of sophisticated scientific instruments. The robust beamlines at NSLS produce remarkable science, and we made excellent progress on developing NSLS-II beamlines and associated science programs." - Qun Shen Director, Photon Division While keeping the existing ring and beamline mechanical systems running, Photon Sciences staff completed a number of R&D projects this year that will improve the tools of researchers at NSLS and, in the near future, NSLS-II. One of the major accomplishments was the installation and commissioning of

313

ACDOS1: A COMPUTER CODE TO CALCULATE DOSE RATES FROM NEUTRON ACTIVATION OF NEUTRAL BEAMLINES AND OTHER FUSION REACTOR COMPONENTS  

E-Print Network (OSTI)

the Tokamak Fusion Test Reactor Test Cell", Nucl. Technol.BEAMLINES AND OTHER FUSION--REACTOR COMPONENTS Gregory S.Beamlines and Other Fusion-Reactor Compon ents By Gregory

Keney, G.S.

2010-01-01T23:59:59.000Z

314

Geometry and parameter optimization of PETRA undulator beamline slits  

SciTech Connect

The undulator beamline at the storage ring PETRA of the Hamburger Synchrotronstrahlungslabor HASYLAB delivers hard x-ray photons usable up to 300 keV. The total power of the beam is now up to 7.5 kW with closed gap and 60 mA stored particle beam. After a planned upgrade of the undulator, the power can increase to about 15 kW. The vertical white beam slit for the PETRA undulator beamline is located at about 105 m from the source. The worst case for the slit is when all the power is absorbed in one part of the slit system, which the slits must survive. This paper presents the results from parameter optimization in the worst case. The goal of the optimization is to minimize the maximum temperature of the slits. The geometrical parameters are the cooling hole size, its location from the surface, and the distance between holes. The worst case is found by moving the x-ray beam to all the possible locations. The maximum temperature of an optimized slit that has a two degree angle with the beam is about 192 degrees Celsius. The corresponding thermal stress in the slit is very low. The analysis assumptions, modeling, results, discussion, and conclusion will be given in the paper. 5 refs., 4 figs.

Wang, Z. [Argonne National Lab., IL (United States); Hahn, U. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Hamburger Synchrotronstrahlungslabor

1996-08-01T23:59:59.000Z

315

Construction of bending magnet beamline at the APS for environmental studies. 1998 annual progress report  

SciTech Connect

'Design and construction of a bending magnet beamline at the Advanced Photon Source (APS) by the Pacific Northwest Consortium-Collaborative Access Team (PNC-CAT). The beamline will be optimized for x-ray absorption spectroscopy (XAS) studies with a major focus on environmental issues. The beamline will share the experimental facilities under development at the neighboring undulator based insertion device beamline. It will utilize these facilities for XAS of both bulk and surface samples, with spatial and elemental imaging, on toxic and radioactive samples. It will help meet the rapidly growing need for the application of these techniques to environmental problems. This report summarizes progress after 1-1/2 years of a 3-year project. The original scope of the project was to build a basic bending magnet beamline. Since the start of the project the authors have obtained addition funding from DOE-BES for the PNC-CAT activities. This has allowed us to expand the scope of the original proposed bending magnet beamline. Additional items now planned include a full sized experimental enclosure separate from the first optical enclosure (FOE), a white beam vertically collimating/focusing mirror providing improved flux and focusing, and enhanced experimental capabilities. Construction of the FOE and new experimental enclosure are complete along with full sector utilities, and the FOE is currently undergoing validation for its radiation integrity. The major beamline components are still being funded by the original EMSP project, and their status is described'

Stern, E.A.

1998-06-01T23:59:59.000Z

316

Photon Sciences | Beamlines | IXS: Inelastic X-ray Scattering  

NLE Websites -- All DOE Office Websites (Extended Search)

IXS: Inelastic X-ray Scattering IXS: Inelastic X-ray Scattering Poster | Fact Sheet | Preliminary Design Report Scientific Scope Many hot topics related to the high frequency dynamics of condensed matter require both a narrower and steeper resolution function and access to a broader dynamic range than what are currently available. This represents a sort of "no man's land" that falls right in the dynamic gap lying between the high frequency spectroscopies, such as inelastic x-ray scattering (IXS), and the low frequency ones. New IXS spectrometers with improved energy and momentum resolutions would be required to fill this gap. To achieve this goal, a new x-ray optics concept for both the monochromatization and energy analysis of x-rays will be implemented at the NSLS-II Inelastic X-ray Scattering beamline. This solution exploits the

317

FRONTIER SYNCHROTRON INFRARED SPECTROSCOPY BEAMLINE UNDER EXTREME CONDITIONS (FIS)  

NLE Websites -- All DOE Office Websites (Extended Search)

FRONTIER SYNCHROTRON INFRARED SPECTROSCOPY FRONTIER SYNCHROTRON INFRARED SPECTROSCOPY BEAMLINE UNDER EXTREME CONDITIONS (FIS) Proposal Team: L. Carr 1 , D. Dolan 2 , R. Hemley 3 , S. Jacobson 4 , S. Karato 5 , Z. Liu 3 , W. Panero 6 , M. Pravica 7 , and T. Zhou 8 1 Brookhaven National Laboratory, 2 Sandia National Laboratories, 3 Carnegie Institution of Washington, 4 Northwestern University, 5 Yale University, 6 Ohio State University, 7 University of Nevada, 8 New Jersey Institute of Technology TECHNIQUES AND CAPABILITIES APPLICATIONS SPECIFIC PROJECTS / ADDITIONAL INFORMATION * TECHNIQUE(S): Fourier transform infrared spectroscopy; Raman and visible spectroscopy; Diamond anvil cell techniques for static high pressure; Gas-gun launchers for dynamic compression; Cryogenic techniques combined with DACs;

318

Photon Sciences | Beamlines | SRX: Submicron Resolution X-ray Spectroscopy  

NLE Websites -- All DOE Office Websites (Extended Search)

SRX: Submicron Resolution X-ray Spectroscopy SRX: Submicron Resolution X-ray Spectroscopy Poster | Fact Sheet | Preliminary Design Report Scientific Scope Scientific communities such as environmental sciences, life sciences, and material sciences have identified the need to develop analytical resources to advance the understanding of complex natural and engineered systems that are heterogeneous on the micron to nanometer scale. These needs for high intensity x-ray nanoprobes resulted in the commitment of the NSLS-II Project to build the Submicron Resolution X-ray (SRX) Spectroscopy beamline showing a unique combination of high spectral resolution over a very broad energy range and very high beam intensity in a sub-micrometer spot. NSLS-II will provide one of the best sources in the world for such an instrument.

319

Alignment of the photoelectron spectroscopy beamline at NSRL  

E-Print Network (OSTI)

The photoelectron spectroscopy beamline at National Synchrotron Radiation Laboratory (NSRL) is equipped with a spherical grating monochromator with the included angle of 174 deg. Three gratings with line density of 200, 700 and 1200 lines/mm are used to cover the energy region from 60 eV to 1000 eV. After several years operation, the spectral resolution and flux throughput were deteriorated, realignment is necessary to improve the performance. First, the wavelength scanning mechanism, the optical components position and the exit slit guide direction are aligned according to the design value. Second, the gratings are checked by Atomic Force Microscopy (AFM). And then the gas absorption spectrum is measured to optimize the focusing condition of the monochromator. The spectral resolving power is recovered to the designed value of 1000@244eV. The flux at the end station for the 200 lines/mm grating is about 10^10 photons/sec/200mA, which is in accordance with the design. The photon flux for the 700 lines/mm grating is about 5 X 10^8 photons/sec/200mA, which is lower than expected. This poor flux throughput may be caused by carbon contamination on the optical components. The 1200 lines/mm grating has roughness much higher than expected so the diffraction efficiency is too low to detect any signal. A new grating would be ordered. After the alignment, the beamline has significant performance improvements in both the resolving power and the flux throughput for 200 and 700 lines/mm gratings and is provided to users.

Chaoyang Li; Hanbin Pan; Shen Wen; Congyuan Pan; Ning An; Xuewei Du; Junfa Zhu; Qiuping Wang

2013-03-04T23:59:59.000Z

320

PLANT BIOLOGY DEPARTMENT HANDBOOK  

E-Print Network (OSTI)

PLANT BIOLOGY DEPARTMENT HANDBOOK 2012-2013 University of Georgia Athens, GA 30602 Updated: 9/5/12 #12;Plant Biology Handbook Table of Contents General Information and Operating Procedures 1

Arnold, Jonathan

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Design Concept and Performance of the Soft X-ray Beamline HiSOR-BL14  

SciTech Connect

The soft X-ray beamline HiSOR-BL14 has been constructed at Hiroshima Synchrotron Radiation Center, aimed at absorption spectroscopy and photoelectron spectroscopy with linearly and circularly polarized light. The beamline layout is based on a Dragon-type design with a spherical grating monochromator. The beamline is able to accept synchrotron radiation from the bending magnet part of the HiSOR ring with a wide solid angle. The large horizontal angular acceptance and vertical one contribute to high photon flux and controllability of light polarization, respectively. Our performance test indicates that high resolving power has been achieved with sufficient photon flux to carry out spectroscopic experiments.

Sawada, M.; Namatame, H. [Hiroshima Synchrotron Radiation Center, Hiroshima University, Kagamiyama 2-313, Higashi-Hiroshima, Hiroshima 739-0046 (Japan); Yaji, K. [Institute for Solid State Physics, University of Tokyo, Kashiwanoha 5-1-5, Kashiwa, Chiba 277-8581 (Japan); Nagira, M.; Kimura, A.; Taniguchi, M. [Graduate School of Science, Hiroshima University, Kagamiyama 1-3-1, Higashi-Hiroshima, Hiroshima 739-0046 (Japan)

2007-01-19T23:59:59.000Z

322

Recent Major Improvements to the ALS Sector 5 MacromolecularCrystallography Beamlines  

Science Conference Proceedings (OSTI)

Although the Advanced Light Source (ALS) was initially conceived primarily as a low energy (1.9GeV) 3rd generation source of VUV and soft x-ray radiation it was realized very early in the development of the facility that a multipole wiggler source coupled with high quality, (brightness preserving), optics would result in a beamline whose performance across the optimal energy range (5-15keV) for macromolecular crystallography (MX) would be comparable to, or even exceed, that of many existing crystallography beamlines at higher energy facilities. Hence, starting in 1996, a suite of three beamlines, branching off a single wiggler source, was constructed, which together formed the ALS Macromolecular Crystallography Facility. From the outset this facility was designed to cater equally to the needs of both academic and industrial users with a heavy emphasis placed on the development and introduction of high throughput crystallographic tools, techniques, and facilities--such as large area CCD detectors, robotic sample handling and automounting facilities, a service crystallography program, and a tightly integrated, centralized, and highly automated beamline control environment for users. This facility was immediately successful, with the primary Multiwavelength Anomalous Diffraction beamline (5.0.2) in particular rapidly becoming one of the foremost crystallographic facilities in the US--responsible for structures such as the 70S ribosome. This success in-turn triggered enormous growth of the ALS macromolecular crystallography community and spurred the development of five additional ALS MX beamlines all utilizing the newly developed superconducting bending magnets ('superbends') as sources. However in the years since the original Sector 5.0 beamlines were built the performance demands of macromolecular crystallography users have become ever more exacting; with growing emphasis placed on studying larger complexes, more difficult structures, weakly diffracting or smaller crystals, and on more rapidly screening larger numbers of candidate crystals; all of these requirements translate directly into a pressing need for increased flux, a tighter beam focus and faster detectors. With these growing demands in mind a major program of beamline and detector upgrades was initiated in 2004 with the goal of dramatically enhancing all aspects of beamline performance. Approximately $3 million in funding from diverse sources including NIH, LBL, the ALS, and the industrial and academic members of the beamline Participating Research Team (PRT), has been employed to develop and install new high performance beamline optics and to purchase the latest generation of CCD detectors. This project, which reached fruition in early 2007, has now fulfilled all of its original goals--boosting the flux on all three beamlines by up to 20-fold--with a commensurate reduction in exposure and data acquisition times for users. The performance of the Sector 5.0 beamlines is now comparable to that of the latest generation ALS superbend beamlines and, in the case of beamline 5.0.2, even surpasses it by a considerable margin. Indeed, the present performance of this beamline is now, once again, comparable to that envisioned for many MX beamlines planned or under construction on newer or higher energy machines.

Morton, Simon A.; Glossinger, James; Smith-Baumann, Alexis; McKean, John P.; Trame, Christine; Dickert, Jeff; Rozales, Anthony; Dauz,Azer; Taylor, John; Zwart, Petrus; Duarte, Robert; Padmore, Howard; McDermott, Gerry; Adams, Paul

2007-07-01T23:59:59.000Z

323

ANL/APS/TB-21 Radiation Shielding of Insertion Device Beamlines  

NLE Websites -- All DOE Office Websites (Extended Search)

1 1 Radiation Shielding of Insertion Device Beamlines Using a Mirror as the First Optical Element W. Yun, B. Lai, K. J. Randall, S. Davey, D. R. Haeffner, P. K. Job, and D. Shu February 1995 Abstract The radiation shielding for an Advanced Photon Source (APS) insertion device beamline using a mirror as the first optical component is discussed. The beamline layout for a specific Synchrotron Radiation Instrumentation Collaborative Access Team beamline (sector 2 of SRI CAT) is described, and the methodology used to determine the radiation shielding is presented. Results indicate that, by using a x-ray mirror with a critical energy of 32 keV for total reflection, an undulator beam containing nearly all x-rays in the 0 - 32 keV spectral range can be delivered

324

The Commissioning Results of the First Beamline at the Siam Photon Laboratory  

SciTech Connect

The commissioning results obtained from the first beamline of the Siam Photon Source are reported. The beamline is a VUV beamline in which light is monochromatized over the energy range between 20-240 eV. The wavelength calibration was carried out by photoemission measurements using the Fermi edge of gold as the standard. The optical beamline and the experimental station have been tested while the Siam Photon Source was still in the commissioning period. This gave rise to undesirable problems: the large electron beam size, the beam instability and the following intensity fluctuation. Such problem has been overcome up to the present. The photoemission measurements are being carried out on Ni(111)

Songsiriritthigul, Prayoon; Pairsuwan, W.; Ishii, T. [National Synchrotron Research Center, Nakhon-ratchasima, 30000 (Thailand); School of Physics, Suranaree University of Technology, Nakhon-ratchasima 30000 (Thailand); Nakajima, H. [National Synchrotron Research Center, Nakhon-ratchasima, 30000 (Thailand); Kantee, S.; Wongkokua, W. [School of Physics, Suranaree University of Technology, Nakhon-ratchasima 30000 (Thailand); Kakizaki, A. [Institute for Solid State Physics, University of Tokyo, Kashiwanoha 5-1-5, Kashiwa, Chiba 277-8581 (Japan)

2004-05-12T23:59:59.000Z

325

ANL/APS/TB-14 APS Beamline Design and Construction Requirements:  

NLE Websites -- All DOE Office Websites (Extended Search)

14 14 APS Beamline Design and Construction Requirements: A Reference Manual for Designers and Builders Version 1.0 May 1994 iii TABLE OF CONTENTS SECTION I DEFINITIONS, GUIDELINES, AND REVIEW CRITERIA ............................1 1. Introduction (July 21, 1998) ...............................................................................................1 1.1 About the Advanced Photon Source ...........................................................................1 1.2 About this Manual.......................................................................................................1 2. Beamline Definitions and Responsibilities (July 21, 1998) .................................................2 2.1 Definitions...................................................................................................................2

326

A modified post damping ring bunch compressor beamline for the TESLA linear collider  

SciTech Connect

We propose a modified bunch compressor beamline, downstream of the damping ring, for the TESLA linear collider. This modified beamline uses a third harmonic radio-frequency section based on the 3.9 GHz superconducting cavity under development at Fermilab. In our design the beam deceleration is about {approx}50 MeV instead of {approx}450 MeV in the original design proposed.

Philippe R.-G. Piot; Winfried Decking

2004-03-23T23:59:59.000Z

327

Alignment of the photoelectron spectroscopy beamline at NSRL  

E-Print Network (OSTI)

The photoelectron spectroscopy beamline at National Synchrotron Radiation Laboratory (NSRL) is equipped with a spherical grating monochromator with the included angle of 174 deg. Three gratings with line density of 200, 700 and 1200 lines/mm are used to cover the energy region from 60 eV to 1000 eV. After several years operation, the spectral resolution and flux throughput were deteriorated, realignment is necessary to improve the performance. First, the wavelength scanning mechanism, the optical components position and the exit slit guide direction are aligned according to the design value. Second, the gratings are checked by Atomic Force Microscopy (AFM). And then the gas absorption spectrum is measured to optimize the focusing condition of the monochromator. The spectral resolving power is recovered to the designed value of 1000@244eV. The flux at the end station for the 200 lines/mm grating is about 10^10 photons/sec/200mA, which is in accordance with the design. The photon flux for the 700 lines/mm grati...

Li, Chaoyang; Wen, Shen; Pan, Congyuan; An, Ning; Du, Xuewei; Zhu, Junfa; Wang, Qiuping

2013-01-01T23:59:59.000Z

328

DESIGN OF VISIBLE DIAGNOSTIC BEAMLINE FOR NSLS2 STORAGE RING  

SciTech Connect

A visible synchrotron light monitor (SLM) beam line has been designed at the NSLS2 storage ring, using the bending magnet radiation. A retractable thin absorber will be placed in front of the first mirror to block the central x-rays. The first mirror will reflect the visible light through a vacuum window. The light is guided by three 6-inch diameter mirrors into the experiment hutch. In this paper, we will describe design work on various optical components in the beamline. The ultra high brightness NSLS-II storage ring is under construction at Brookhaven National Laboratory. It will have 3GeV, 500mA electron beam circulating in the 792m ring, with very low emittance (0.9nm.rad horizontal and 8pm.rad vertical). The ring is composed of 30 DBA cells with 15 fold symmetry. Three damping wigglers will be installed in long straight sections 8, 18 and 28 to lower the emittance. While electrons pass through the bending magnet, synchrotron radiation will be generated covering a wide spectrum. There are other insertion devices in the storage ring which will generate shorter wavelength radiation as well. Synchrotron radiation has been widely used as diagnostic tool to measure the transverse and longitudinal profile. Three synchrotron light beam lines dedicated for diagnostics are under design and construction for the NSLS-II storage ring: two x-ray beam lines (pinhole and CRL) with the source points from Cell 22 BM{_}A (first bending in the DBA cell) and Cell22 three-pole wiggler; the third beam line is using visible part of radiation from Cell 30 BM{_}B (second bending magnet from the cell). Our paper focuses on the design of the visible beam line - SLM.

Cheng, W.; Fernandes, H.; Hseuh, H.; Kosciuk, B.; Krinsky, S.; Singh, O.

2011-03-28T23:59:59.000Z

329

Photon Sciences | Beamlines | CSX: Coherent Soft X-ray Scattering and  

NLE Websites -- All DOE Office Websites (Extended Search)

CSX: Coherent Soft X-ray Scattering and polarization CSX: Coherent Soft X-ray Scattering and polarization X-Ray 1 Poster | X-Ray 2 Poster | Fact Sheet | Preliminary Design Report Scientific Scope The Coherent Soft X-ray Scattering and Polarization (CSX) beamline design (source and optics) has been optimized to the NSLS-II parameters to provide the highest possible flux for experiments requiring either high coherence or full control of the polarization. Beamline Description The CSX beamline will be served by two identical EPU49 sources. Both EPUs are planned to operate in a canted geometry with opposite circular polarization for fast polarization switching experiments at the full polarization control (PC) branch. The EPUs will also be able to operate "phased" as a single device for high coherent flux experiments at the

330

Thermal, structural, and fabrication aspects of diamond windows for high power synchrotron x-ray beamlines  

SciTech Connect

Recent advances in chemical vapor deposition (CVD) technology have made it possible to produce thin free-standing diamond foils that can be used as the window material in high heat load, synchrotron beamlines. Numerical simulations suggest that these windows can offer an attractive and at times the only altemative to beryllium windows for use in third generation x-ray synchrotron radiation beamlines. Utilization, design, and fabrication aspects of diamond windows for high heat load x-ray beamlines are discussed, as are the microstructure characteristics bearing on diamond`s performance in this role. Analytic and numerical results are also presented to provide a basis for the design and testing of such windows.

Khounsary, A.M. [Argonne National Lab., IL (United States); Phillips, W. [Crystallume, Menlo Park, CA (United States)

1992-12-01T23:59:59.000Z

331

Thermal, structural, and fabrication aspects of diamond windows for high power synchrotron x-ray beamlines  

SciTech Connect

Recent advances in chemical vapor deposition (CVD) technology have made it possible to produce thin free-standing diamond foils that can be used as the window material in high heat load, synchrotron beamlines. Numerical simulations suggest that these windows can offer an attractive and at times the only altemative to beryllium windows for use in third generation x-ray synchrotron radiation beamlines. Utilization, design, and fabrication aspects of diamond windows for high heat load x-ray beamlines are discussed, as are the microstructure characteristics bearing on diamond's performance in this role. Analytic and numerical results are also presented to provide a basis for the design and testing of such windows.

Khounsary, A.M. (Argonne National Lab., IL (United States)); Phillips, W. (Crystallume, Menlo Park, CA (United States))

1992-01-01T23:59:59.000Z

332

High-brightness beamline for X-ray spectroscopy at the Advanced Light Source  

SciTech Connect

Beamline 9.3.1 at the Advanced Light Source (ALS) is a windowless beamline, covering the 1-6 keV photon-energy range, designed to achieve the goals of high energy resolution, high flux, and high brightness at the sample. When completed later this year, it will be the first ALS monochromatic hard-x-ray beamline, and its brightness will be an order-of-magnitude higher than presently available in this energy range. In addition, it will provide flux and resolution comparable to any other beamline now in operation. To achieve these goals, two technical improvements, relative to existing x-ray beamlines, were incorporated. First, a somewhat novel optical design for x-rays, in which matched toroidal mirrors are positioned before and after the double-crystal monochromator, was adopted. This configuration allows for high resolution by passing a collimated beam through the monochromator, and for high brightness by focusing the ALS source on the sample with unit magnification. Second, a new ''Cowan type'' double-crystal monochromator based on the design used at NSLS beamline X-24A was developed. The measured mechanical precision of this new monochromator shows significant improvement over existing designs, without using positional feedback available with piezoelectric devices. Such precision is essential because of the high brightness of the radiation and the long distance (12m) from the source (sample) to the collimating (focusing) mirror. This combination of features will provide a bright, high resolution, and stable x-ray beam for use in the x-ray spectroscopy program at the ALS.

Perera, R.C.C.; Jones, G. [Lawrence Berkeley Lab., CA (US); Lindle, D.W. [Univ. of Nevada, Las Vegas, NV (US). Dept. of Chemistry

1994-08-01T23:59:59.000Z

333

APS beamline standard components handbook, Version 1.3. Revision 1  

SciTech Connect

This Handbook in its current version (1.3) contains descriptions, specifications, and preliminary engineering design drawings for many of the standard components. The design status and schedules have been provided wherever possible. In the near future, the APS plans to update engineering drawings of identified standard beamline components and complete the Handbook. The completed version of this Handbook will become available to both the CATs and potential vendors. Use of standard components should result in major cost reductions for CATs in the areas of beamline design and construction.

Hahn, U.; Shu, D.; Kuzay, T.M.

1993-02-01T23:59:59.000Z

334

Properties of ion implanted Ti-6Al-4V processed using beamline and PSII techniques  

DOE Green Energy (OSTI)

The surface of Ti-6Al-4V (Ti64) alloy has been modified using beamline implantation of boron. In separate experiments, Ti64 has been implanted with nitrogen using a plasma source ion implantation (PSII) technique utilizing either ammonia (NH{sub 3}), nitrogen (N{sub 2}), or their combinations as the source of nitrogen ions. Beamline experiments have shown the hardness of the N-implanted surface saturates at a dose level of {approximately} 4 {times} 10{sup 17} at/cm{sup 2} at {approximately} 10 GPa. The present work makes comparisons of hardness and tribological tests of (1) B implantation using beamline techniques, and (2) N implanted samples using ammonia and/or nitrogen gas in a PSII process. The results show that PSII using N{sub 2} or NH{sub 3} gives similar hardness as N implantation using a beamline process. The presence of H in the Ti alloy surface does not affect the hardness of the implanted surface. Boron implantation increased the surface hardness by as much as 2.5x at the highest dose level. Wear testing by a pin-on-disk method indicated that nitrogen implantation reduced the wear rate by as much as 120x, and boron implantation reduced the wear rate by 6.5x. Increased wear resistance was accompanied by a decreased coefficient of friction.

Walter, K.C.; Woodring, J.S.; Nastasi, M.; Munson, C.M. [Los Alamos National Lab., NM (United States); Williams, J.M.; Poker, D.B. [Oak Ridge National Lab., TN (United States). Solid State Div.

1996-12-31T23:59:59.000Z

335

Paraxial SGM beamlines for coherence experiments at the Advanced Light Source  

Science Conference Proceedings (OSTI)

Beamlines have been designed for coherence experiments at the ALS based on brightness preserving spherical grating monochromators. The operation is almost paraxial so that a very simple scheme can deliver the modest spectral resolution required, with just two focusing optics, one of which is the spherical grating.

Warwick, Anthony I; Warwick, Anthony I; Howells, Malcolm

2008-07-24T23:59:59.000Z

336

7-GeV advanced photon source beamline initiative: Conceptual design report  

Science Conference Proceedings (OSTI)

The DOE is building a new generation 6-7 GeV Synchrotron Radiation Source known as the Advanced Photon Source (APS) at Argonne National Laboratory. This facility, to be completed in FY 1996, can provide 70 x-ray sources of unprecedented brightness to meet the research needs of virtually all scientific disciplines and numerous technologies. The technological research capability of the APS in the areas of energy, communications and health will enable a new partnership between the DOE and US industry. Current funding for the APS will complete the current phase of construction so that scientists can begin their applications in FY 1996. Comprehensive utilization of the unique properties of APS beams will enable cutting-edge research not currently possible. It is now appropriate to plan to construct additional radiation sources and beamline standard components to meet the excess demands of the APS users. In this APS Beamline Initiative, 2.5-m-long insertion-device x-ray sources will be built on four straight sections of the APS storage ring, and an additional four bending-magnet sources will also be put in use. The front ends for these eight x-ray sources will be built to contain and safeguard access to these bright x-ray beams. In addition, funds will be provided to build standard beamline components to meet scientific and technological research demands of the Collaborative Access Teams. The Conceptual Design Report (CDR) for the APS Beamline Initiative describes the scope of all the above technical and conventional construction and provides a detailed cost and schedule for these activities. The document also describes the preconstruction R&D plans for the Beamline Initiative activities and provides the cost estimates for the required R&D.

Not Available

1993-05-01T23:59:59.000Z

337

RADIOACTIVE IODINE IN THE TREATMENT OF HYPERTHYROIDISM (EXPERIENCE AT THE TORONTO GENERAL HOSPITAL, 1950-58). PART III. POSSIBLE BIOLOGICAL HAZARDS FROM RADIOACTIVE IODINE THERAPY  

SciTech Connect

A review of 542 hyperthyroid patients treated by I/sup 131/ at the Toronto General Hospital between 1950 and 1955 is presented. This group included 403 patients with diffuse hyperplastic goitre and 139 patients with toxic nodular goitre. The method for assessing the initial dose of I/sup 131/ is described. In general, patients with toxic nodular goitres received much larger doses. Of the diffuse hyperplastic group 72% were cured with one dose, the remainder requiring two or more doses. A greater percentage of the toxic nodular group required only one dose. No cases of complete resistance to 1/sup 131/ therapy were encountered. Permanent hypothyroidism was produced in 16.3% of those so treated, but in 6.5% it was very mild. The incidence of clinical hypothyroidism was much lower in the toxic nodular group than in the diffuse hyperplastic group. There was a continuing incidence of late hypothyroidism, occurring years after therapy; some of these patients had undergone a transient period of hypothyroidism shortly after treatment, then recovered for some years. Factors possibly related to the response to treatment and to the development of hypothyroidism have been analyzed. Recurrent hyperthyroidism after thyroidectomy was associated with a significant increase in the incidence of post-I/sup 131/ hypothyroidism, while pretreatment with artithyroid drugs seemed to reduce radiosensitivity in the diffuse group. No late recurrences of hyperthyroidism were noted. Twenty-one deaths occurred within two years of therapy. In most, there was no obvious relation to therapy, while in none was there a clear-out cause-and-effect relationship to I/sup 131/ therapy. Nevertheless, elderly or very ill patients should be treated only after they have been rendered euthyroid by antithyroid drugs. Fertility has not been affected by I/sup 131/ therapy, but the use of this isotope in pregnancy is contraindicated because of the possible ill effects on the fetas. The possibility of genetic effects appears to be negligible, as judged by the gonadal radiation doses received in I/sup 131/ therapy. The fear of carcinoma of the thyroid likewise appears to be receding if the therapy is utilized only in adults. Leukemia has been reported in 14 instances. However, the statistical import is not clear, since the total number of cases of leukemia and of persons treated by I/sup 131/ is not known. It may be that there is a slight increase in the incidence of leukemia following radioactive treatment, comparable to that possibly induced by certain diagnostic radiological procedures, but this is insufficient to warrant any change in policy regarding the use of I/sup 131/ After consideration of these hypothetical dangers, it is concluded that the use of radioactive iodine is a safe, effective form of therapy for adult, nonpregnant hyperthyroid patients, and is to be preferred to surgical thyroidectomy. 108 references. (auth)

Volpe, R.; Schatz, D.L.; Scott, A.; Peller, J.A.; Vale, J.M.; Ezrin, C.; Johnston, M.W.

1961-01-14T23:59:59.000Z

338

Biology basics  

NLE Websites -- All DOE Office Websites (Extended Search)

Biology basics Name: lamb Status: NA Age: NA Location: NA Country: NA Date: Around 1993 Question: What basic knowledge concerning biology do you think a colleg- bound HS...

339

X-ray Absorption Spectroscopy Beamline at the Siam Photon Laboratory  

SciTech Connect

A bending magnet beamline has been constructed and commissioned for x-ray absorption spectroscopy (XAS) at the Siam Photon Laboratory. The photon energy is tunable from 1830 eV to 8000 eV using a Lemmonier-type, fixed-exit double crystal monochromator equipped with InSb(111), Si(111), Ge(220) crystals. Elemental K-edges are then accessible from silicon to iron. A series of low conductance vacuum tubes has been designed and installed between the pumping chambers in the front end to obtain the proper pressure difference between the upstream and the downstream of the front end. Thus lower-energy photons, around K-edges of silicon, phosphorous, and sulfur, can be delivered to the experimental XAS station without being absorbed by a window. In this report, the design of the beamline is described. The commissioning results including the measured photon flux at sample and experimental XAS spectra are presented.

Klysubun, Wantana; Tarawarakarn, Pongjakr; Sombunchoo, Panidtha; Klinkhieo, Supat; Chaiprapa, Jitrin [National Synchrotron Research Center, 111 University Ave., Muang District, Nakhon Ratchasima 30000 (Thailand); Songsiriritthigul, Prayoon [National Synchrotron Research Center, 111 University Ave., Muang District, Nakhon Ratchasima 30000 (Thailand); School of Physics, Suranaree University of Technology, Nakhon Ratchasima 30000 (Thailand)

2007-01-19T23:59:59.000Z

340

Beamline and exposure station for deep x-ray lithography at the Advanced Photon Source  

Science Conference Proceedings (OSTI)

APS is a third-generation synchrotron radiation source. With an x-ray energy of 19.5 keV and highly collimated beam ( 1 mm) using deep x-ray lithography (DXRL). The 2-BM beamline was constructed and will be used for DXRL at APS. Selection of appropriate x-ray energy range is done through a variable-angle mirror and various filters in the beamline. At the exposure station, the beam size will be 100(H) x 5(V) mm{sup 2}. Uniform exposure will be achieved by a high-speed (100 mm/sec) vertical scanner, which allows precise angular ({approximately}0.1 mrad) and positional (conicals and other profiles. For 1-mm-thick PMMA, a 100 x 25 mm{sup 2} area can be fully exposed in about 1/2 hr, while even 10-mm-thick PMMA will require only 2-3 hours.

Lai, B.; Mancini, D.C.; Yun, W.; Gluskin, E.

1996-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

NEWTON's Molecular Biology References  

NLE Websites -- All DOE Office Websites (Extended Search)

Molecular Biology References Molecular Biology References Do you have a great reference link? Please click our Ideas page. Featured Reference Links: The Vitual Museum of Bacteria The Vitual Museum of Bacteria Visit the virtual museum of bacteria to learn more about bacteria and germs! This site brings together many links on bacteria, bacteriology, and related topics available on the web. It also provides crystal-clear information about many aspects of bacteria. The American Society of Cell Biology Cell Biology Educational Resources This site, sponsered by the American Society of Cell Biology, provides additional web links to everything from, general educational sites, to biology course materials, to teaching tools and more. National Center for Biotechnology Information National Center for Biotechnology Information

342

ANL/APS/TB-24 Diamond Monochromators for APS Undulator-A Beamlines  

NLE Websites -- All DOE Office Websites (Extended Search)

4 4 Diamond Monochromators for APS Undulator-A Beamlines R.C. Blasdell, L. A. Assoufid, and D. M. Mills TABLE OF CONTENTS 1. INTRODUCTION .................................................................................1 2. PHYSICAL PROPERTIES OF DIAMONDS ..................................................5 2.1 Varieties of Diamonds ....................................................................5 2.2 The Lattice Parameter .....................................................................5 2.3 Bulk Thermal and Mechanical Properties ...............................................6 2.4 Typical Surface and Lattice Plane Morphology ......................................8 2.5 The Liquid-GaIn/Diamond Interface ...................................................10 3. DIFFRACTION PROPERTIES OF DIAMOND

343

Biological Applications of Synchrotron Radiation:  

NLE Websites -- All DOE Office Websites (Extended Search)

Biological Applications of Synchrotron Radiation: Biological Applications of Synchrotron Radiation: An Evaluation of the State of the Field in 2002 A BioSync Report. Issued by the Structural Biology Synchrotron users Organization, October, 2002. 2 Table of Contents: Introduction .................................................................................................... 3 Abbreviations .................................................................................................. 5 Executive Summary ......................................................................................... 6 General Concerns ............................................................................................ 9 Synchrotron operations and maintenance ............................................... 9 NSLS, CHESS and the geographical distribution of beam lines

344

Performance of the BL4 Beamline for Surface and Interface Research at the Siam Photon Laboratory  

SciTech Connect

The evaluations of the monochromator of the BL4 beamline at the Siam Photon Laboratory were carried out by gas-phase photoionization measurements. The beamline employs a varied-line-spacing plane grating monochromator, which delivers photons with energies between 20-240 eV. The resolving power of the monochromator depends strongly with the alignment of the exit slit. The designed resolving power of 5000 has been achieved. The experimental station of the beamline has been upgraded for surface and interface research. The new experimental station removes the disadvantage and expands the capabilities of the old one in such a way that photoemission experiments using synchrotron light can be performed in parallel with other in situ surface analysis techniques, as well as with preparation of other samples. The new system includes the old photoemission system and a multi-UHV-chamber system. The standard surface-sensitive techniques available in addition to photoemission spectroscopy using synchrotron light are UPS, XPS, AES and LEED. The new experimental station also includes a metal MBE system for preparing samples for the studies of ultra-thin magnetic films and metal-semiconductor interfaces.

Nakajima, Hideki [National Synchrotron Research Center, 111 University Avenue, Muang District, Nakhon Ratchasima 30000 (Thailand); Buddhakala, Moragote; Chumpolkulwong, Somchai; Supruangnet, Ratchadapora [School of Physics, Suranaree University of Technology, 111 University Avenue, Muang District, Nakhon Ratchasima 30000 (Thailand); Kakizaki, Akito [Institute for Solid State Physics, University of Tokyo, Kashiwa, Chiba 227-8581 (Japan); Songsiriritthigul, Prayoon [National Synchrotron Research Center, 111 University Avenue, Muang District, Nakhon Ratchasima 30000 (Thailand); School of Physics, Suranaree University of Technology, 111 University Avenue, Muang District, Nakhon Ratchasima 30000 (Thailand)

2007-01-19T23:59:59.000Z

345

The Midwest Analytical Team for Research Instrumentation of X-Rays (MATRIX) Beamline X-18A at the National Synchrotron Light Source of Brookhaven National Laboratory  

Science Conference Proceedings (OSTI)

During six years of funding, the MATRIX beamline was successful in the production of research on identification of transformation and transitions in materials.

Bowman, Keith J.

2001-01-01T23:59:59.000Z

346

General Information  

NLE Websites -- All DOE Office Websites (Extended Search)

Environment Feature Stories Public Reading Room: Environmental Documents, Reports LANL Home Phonebook Calendar Video Business Small Business General Information General...

347

Biological Surety  

E-Print Network (OSTI)

o Identifies the purpose, concept, and responsibilities for the biological surety program (chap 1). o Identifies the following: procedures for requesting exceptions and waivers to biological surety policies; procedures for initiating and terminating surety status; and requirements for surety officers and surety boards (paras 1-5e, 1-6, and 1-7). o Establishes procedures for the biological personnel reliability program

unknown authors

2008-01-01T23:59:59.000Z

348

SYNCH: A program for design and analysis of synchrotrons and beamlines -- user`s guide  

Science Conference Proceedings (OSTI)

SYNCH is a computer program for use in the design and analysis of synchrotrons, storage rings, and beamlines. It has a large repertoire of commands that can be accessed in a flexible way. The input statements and the results of the calculations they invoke are saved in an internal database so that this information may be shared by other statements. SYNCH is the first accelerator program to organize its input in the form of a language. The statements, which resemble sentences, provide a natural way of describing lattices and invoking relevant calculations. The organization of the program is modular, so that it has been possible to expand its capabilities progressively.

Garren, A.A.; Kenney, A.S.; Courant, E.D.; Russell, A.D.; Syphers, M.J.

1993-12-31T23:59:59.000Z

349

Justification for the development of a bending magnet beamline at sector 10 at the APS.  

SciTech Connect

The long-planned and much-needed merger of EnviroCAT into the Materials Research Collaborative Access Team (MR-CAT) will provide dedicated state-of-the-art facilities that are critical to research on a broad range of issues in environmental sciences. These CATs will focus on developing a bending magnet (BM) beamline for x-ray absorption fine structure (XAFS) and micro x-ray analysis of environmental samples through integration with existing insertion device (ID) capabilities in XAFS, micro x-ray analysis, and x-ray scattering. In addition, the expanded MR-CAT will serve as the hub of personnel and laboratory infrastructure support for molecular environmental science and biogeochemical science at the Advanced Photon Source (APS). In conjunction with the merger of EnviroCAT into MR-CAT, the US Environmental Protection Agency (EPA) will become a member institution of MR-CAT, joining the present members (University of Notre Dame, Illinois Institute of Technology, University of Florida, British Petroleum, and Argonne's Chemical Engineering and Biosciences Division). The motivation for blending capabilities meeting the needs of EnviroCAT users into the MR-CAT facilities is the explosion of synchrotron-radiation-based research in the field known as molecular environmental science (MES). This research is driven largely by the need to remediate contaminated environmental materials and to understand the scientific foundations that govern contaminant transport in the environment. Synchrotron radiation is playing a crucial role in solving environmental science problems by offering x-ray-based analytical techniques for detailed molecular- and atomic-level studies of these systems. This document focuses on the scientific justification for developing a specific type of BM beamline capability at Sector 10 for XAFS and micro x-ray analysis to support the growing MES community. However, the modification of Sector 10 will meet other future needs by providing (1) an existing undulator beamline with an experimental station for bulk XAFS applications and x-ray microbeam applications (XRF, XAFS, and XRD) and (2) a BM beamline with an experimental station for large-sample XAFS spectroscopy and XRF elemental mapping on submillimeter to centimeter length scales.

Kemner, K. M.; Biosciences Division

2006-09-18T23:59:59.000Z

350

An energy dispersive x-ray absorption spectroscopy beamline, X6A, at NSLS  

Science Conference Proceedings (OSTI)

An energy dispersive x-ray absorption spectroscopy instrument has been built at the X6A beam port of the x-ray ring at the National Synchrotron Light Source (NSLS). This instrument allows the collection of extended x-ray-absorption fine structure and/or x-ray absorption near-edge structure spectra for many elements on the millisecond time scale. The beamline employs a four-point crystal bender and a rectangular Si 220 crystal to access incident energies between 6.5 and 21 keV. Because the polychromator focuses the synchrotron beam to a narrow 100-[mu]m line, this experimental apparatus is ideal for x-ray absorption spectroscopy experiments in special environments such as at high pressures, for [ital in] [ital situ] experiments, and/or for very small samples. In this manuscript we will describe the instrument design and present data with which to evaluate the instrument. This beamline is available through the NSLS user proposal system.

Lee, P.L.; Beno, M.A.; Jennings, G.; Ramanathan, M.; Knapp, G.S.; Huang, K. (Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States)); Bai, J. (Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States) Department of Physics, Brooklyn College of CUNY, Brooklyn, New York 11210 (United States)); Montano, P.A. (Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States) Department of Physics, University of Illinois, Chicago, Chicago, Illinois 60680 (United States))

1994-01-01T23:59:59.000Z

351

Application of Goubau Surface Wave Transmission Line for Improved Bench Testing of Diagnostic Beamline Elements  

SciTech Connect

In-air test fixtures for beamline elements typically utilize an X-Y positioning stage, and a wire antenna excited by an RF source. In most cases, the antenna contains a standing wave, and is useful only for coarse alignment measurements in CW mode. A surface-wave (SW) based transmission line permits RF energy to be launched on the wire, travel through the beamline component, and then be absorbed in a load. Since SW transmission lines employ travelling waves, the RF energy can be made to resemble the electron beam, limited only by ohmic losses and dispersion. Although lossy coaxial systems are also a consideration, the diameter of the coax introduces large uncertainties in centroid location. A SW wire is easily constructed out of 200 micron magnet wire, which more accurately approximates the physical profile of the electron beam. Benefits of this test fixture include accurate field mapping, absolute calibration for given beam currents, Z-axis independence, and temporal response measurements of sub-nanosecond pulse structures. Descriptions of the surface wave launching technique, transmission line, and instrumentation are presented, along with measurement data.

John Musson, Keith Cole, Sheldon Rubin

2009-05-01T23:59:59.000Z

352

New Developments at the XMaS Beamline For Magnetic and High Resolution Diffraction  

SciTech Connect

We report here on a number of developments that include enhancements of the sample environment on the XMaS beamline and the flux available at low energy. A 4 Tesla superconducting magnet has been designed to fit within the Euler cradle of a six circle Huber diffractometer, allowing scattering in both horizontal and vertical planes. The geometry of the magnet allows the application of longitudinal, transverse horizontal, and vertical fields. A further conventional magnet ({approx} 0.1 T) to minimize air absorption at low energies ({approx} 3KeV) has been designed for two circle applications, such as reflectivity. A novel in-vacuum slit screen has been developed, also minimizing absorption at low energies. New equipment for performing in-situ studies of surfaces in the electrochemical environment has been developed to allow control of the solution and sample temperature over the region of -5C to 80C. Preliminary experiments on the surface reconstructions of Au(111) in an electrolyte have been performed, whilst commissioning at the same time a MAR CCD detector for the beamline.

Thompson, P.B.J.; Bouchenoire, L.; Brown, S.D.; Mannix, D.; Paul, D.F. [XMaS, UK-CRG, ESRF, BP220, F-38043 Grenoble CEDEX (France); Lucas, C.; Kervin, J. [Dept of Physics, University of Liverpool, Liverpool (United Kingdom); Cooper, M.J. [Dept of Physics, University of Warwick, Gibbet Hill Road, Coventry, CV4 7AL (United Kingdom); Arakawa, P.; Laughon, G. [American Magnetics Inc, P.O. Box 2509, 112 Flint Road, Oak Ridge, TN 37831-2509 (United States)

2004-05-12T23:59:59.000Z

353

Beamline and exposure station for deep x-ray lithography at the Advanced Photon Source  

SciTech Connect

APS is a third-generation synchrotron radiation source. With an x-ray energy of 19.5 keV and highly collimated beam (<0.1 mrad), APS is well suited for producing high-aspect-ratio microstructures in thick resist films (> 1 mm) using deep x-ray lithography (DXRL). The 2-BM beamline was constructed and will be used for DXRL at APS. Selection of appropriate x-ray energy range is done through a variable-angle mirror and various filters in the beamline. At the exposure station, the beam size will be 100(H) x 5(V) mm{sup 2}. Uniform exposure will be achieved by a high-speed (100 mm/sec) vertical scanner, which allows precise angular ({approximately}0.1 mrad) and positional (< 1 {mu}m) control of the sample, allowing full use of the highly collimated beam for lateral accuracy and control of sidewall slopes during exposure of thick resists, as well as generation of conicals and other profiles. For 1-mm-thick PMMA, a 100 x 25 mm{sup 2} area can be fully exposed in about 1/2 hr, while even 10-mm-thick PMMA will require only 2-3 hours.

Lai, B.; Mancini, D.C.; Yun, W.; Gluskin, E.

1996-12-31T23:59:59.000Z

354

Huckleberry Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

Huckleberry Biology Name: Katarina Location: NA Country: NA Date: NA Question: Where are huckleberries grown in Illionois and New Jersey? Do you know the names of farms and...

355

Contact-cooled U-monochromators for high heat load x-ray beamlines  

SciTech Connect

This paper describes the design, expected performance, and preliminary test results of a contact-cooled monochromator for use on high heat load x-ray beamlines. The monochromator has a cross section in the shape of the letter U. This monochromator should be suitable for handing heat fluxes up to 5 W/square millimeter. As such, for the present application, it is compatible with the best internally cooled crystal monochromators. There are three key features in the design of this monochromator. First, it is contact cooled, thereby eliminating fabrication of cooling channels, bonding, and undesirable strains in the monochromator due to coolant-manifold-to-crystal-interface. Second, by illuminating the entire length of the crystal and extracting the central part of the reflected beam, sharp slope changes in the beam profile and thus slope errors are avoided. Last, by appropriate cooling of the crystal, tangential slope error can be substantially reduced.

Khounsary, A.; Yun, W.; Trakhtenberg, E.; Xu, S.; Assoufid, L.; Lee, W.K.

1996-12-31T23:59:59.000Z

356

ANL/APS/TB-5 Functional Description of APS Beamline Front Ends  

NLE Websites -- All DOE Office Websites (Extended Search)

Functional Description of APS Beamline Front Ends by Tuncer Kuzay February 1993 Advanced Photon Source & Argonne National Laboratory, Argonne, Illinois 60439 o operated by The University of Chicago for the United States Department of Energy under Contract W-31-1 09-Eng-38 Argonne National Laboratory, with facilties in the states of Ilinois and Idaho, is owned by the United States government, and operated by The University of Chicago under the provisions of a contract with the Deparment of Energy. DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any waranty, express or implied, or assumes any legal liability or responsibility for the accuracy,

357

Report on the value engineering workshop on APS beamline front ends  

SciTech Connect

A formal value engineering evaluation process was developed to address the front end components of the beamlines for the Advanced Photon Source (APS). This process (described in Section 2) involved an information phase, a creative phase, a judgment phase, a development phase, and a recommendation phase. Technical experts from other national laboratories and industry were invited to a two-day Value Engineering Workshop on November 5-6, 1992. The results of this Workshop are described in Section 4. Following the Workshop, various actions by the APS staff led to the redesign of the front end components, which are presented in Sections 5 and 6. The cost benefit analysis is presented in Section 7. It is important of realize that an added benefit of the Workshop was to obtain numerous design evaluations and enhancements of the front end components by experts in the field. As the design work proceeds to Title II completion, the APS staff is including many of these suggestions.

Kuzay, T.

1993-01-01T23:59:59.000Z

358

The first photon shutter development for APS insertion device beamline front ends  

Science Conference Proceedings (OSTI)

One of the most critical components on the Advanced Photon Source (APS) insertion device (ID) beamline front ends is the first photon shutter. It operates in two modes to fully intercept the high total power and high-heat flux ID photon beam in seconds (normal mode) or in less than 100 ms (emergency fast mode). It is designed to operate in ultra high vacuum (UHV). The design incorporates a multi-channel rectangular bar, bent in a ``hockey stick`` configuration, with two-point suspension. The flanged end is an articulated bellows with rolling hinges. The actuation end is a spring-assisted, pneumatic fail-safe flexural pivot type. The coolant (water) channels incorporate brazed copper foam to enhance the heat transfer, a tube technology particular to the APS. The design development, and material aspects, as well as the extensive thermal and vibrational analyses in support of the design, are presented in this paper.

Shu, Deming; Nian, H.L.T.; Wang, Zhibi; Collins, J.T.; Ryding, D.G.; Kuzay, T.M.

1992-09-01T23:59:59.000Z

359

The first photon shutter development for APS insertion device beamline front ends  

Science Conference Proceedings (OSTI)

One of the most critical components on the Advanced Photon Source (APS) insertion device (ID) beamline front ends is the first photon shutter. It operates in two modes to fully intercept the high total power and high-heat flux ID photon beam in seconds (normal mode) or in less than 100 ms (emergency fast mode). It is designed to operate in ultra high vacuum (UHV). The design incorporates a multi-channel rectangular bar, bent in a hockey stick'' configuration, with two-point suspension. The flanged end is an articulated bellows with rolling hinges. The actuation end is a spring-assisted, pneumatic fail-safe flexural pivot type. The coolant (water) channels incorporate brazed copper foam to enhance the heat transfer, a tube technology particular to the APS. The design development, and material aspects, as well as the extensive thermal and vibrational analyses in support of the design, are presented in this paper.

Shu, Deming; Nian, H.L.T.; Wang, Zhibi; Collins, J.T.; Ryding, D.G.; Kuzay, T.M.

1992-01-01T23:59:59.000Z

360

Use of a mirror as the first optical component for an undulator beamline at the APS  

SciTech Connect

In the design of Sector II of the Synchrotron Radiation Instrumentation (SRI) CAT, an x-ray mirror with multiple coatings is chosen as the first optical component of the undulator beamline. Two significant advantages of using the mirror are: A significant reduction in the peak radiation heat flux and total power on the downstream monochromator, and (2) availability of the wide-bandpass undulator spectrum between 0--30 key to experimental stations with substantially reduced radiation shielding requirements. The second advantage also allows us to place the monochromator outside the first optics enclosure (FOE) at a large distance from the source to further reduce the peak heat flux on the monochromator. The combined effect is that the inclined crystal monochromator may not be necessary, and a multilayer monochromator can be used because the expected heat fluxes are less than the value that has been demonstrated for those monochromators.

Yun, W.; Khounsary, A.; Lai, B.; Gluskin, E.

1992-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Gars Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

Gars Biology Name: ryan Location: NA Country: NA Date: NA Question: what kind of fish is a gar? where it lives(fresh or salt water)? what does it eat? what is its protection? is...

362

Easy biology?  

NLE Websites -- All DOE Office Websites (Extended Search)

Easy biology? Name: bobber Status: NA Age: NA Location: NA Country: NA Date: Around 1993 Question: I am a freshman in high school. Although I am not taking science this year, I...

363

Hummingbird Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

Hummingbird Biology Name: Carrie Location: NA Country: NA Date: NA Question: I am interested in the eggs of hummingbirds. We ate at the YMCA of the Ozarks today and they have...

364

Commissioning of a Soft X-ray Beamline PF-BL-16A with a Variable-Included-Angle Varied-Line-Spacing Grating Monochromator  

Science Conference Proceedings (OSTI)

The design and commissioning of a new soft X-ray beamline, BL-16A, at the Photon Factory is presented. The beamline consists of a pre-focusing mirror, an entrance slit, a variable-included-angle varied-line-spacing plane grating monochromator, and a post-focusing system as usual, and provides circularly and linearly polarized soft X rays in the energy range 200-1500 eV with an APPLE-II type undulator. The commissioning procedure for the beamline optics is described in detail, especially the check of the focal position for the zero-th order and diffracted X rays.

Amemiya, Kenta; Toyoshima, Akio; Kikuchi, Takashi; Kosuge, Takashi; Nigorikawa, Kazuyuki; Sumii, Ryohei; Ito, Kenji [Institute of Materials Structure Science, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan)

2010-06-23T23:59:59.000Z

365

BNL | Computational Biology & Bioinformatics  

NLE Websites -- All DOE Office Websites (Extended Search)

Computational Biology & Bioinformatics Computational Biology and Bioinformatics groups focuses on quantitative predictive models of complex biological systems and their underlying...

366

General Engineers  

U.S. Energy Information Administration (EIA) Indexed Site

General Engineers General Engineers The U.S. Energy Information Administration (EIA) within the Department of Energy has forged a world-class information program that stresses quality, teamwork, and employee growth. In support of our program, we offer a variety of profes- sional positions, including the General Engineer, whose work is associated with analytical studies and evaluation projects pertaining to the operations of the energy industry. Responsibilities: General Engineers perform or participate in one or more of the following important functions: * Design modeling systems to represent energy markets and the physical properties of energy industries * Conceive, initiate, monitor and/or conduct planning and evaluation projects and studies of continuing and future

367

Biological preconcentrator  

DOE Patents (OSTI)

A biological preconcentrator comprises a stimulus-responsive active film on a stimulus-producing microfabricated platform. The active film can comprise a thermally switchable polymer film that can be used to selectively absorb and desorb proteins from a protein mixture. The biological microfabricated platform can comprise a thin membrane suspended on a substrate with an integral resistive heater and/or thermoelectric cooler for thermal switching of the active polymer film disposed on the membrane. The active polymer film can comprise hydrogel-like polymers, such as poly(ethylene oxide) or poly(n-isopropylacrylamide), that are tethered to the membrane. The biological preconcentrator can be fabricated with semiconductor materials and technologies.

Manginell, Ronald P. (Albuquerque, NM); Bunker, Bruce C. (Albuquerque, NM); Huber, Dale L. (Albuquerque, NM)

2008-09-09T23:59:59.000Z

368

Biological Evaluation  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Biological Evaluation Biological Evaluation for the Proposed United States Army Military Training Activities on the Savannah River Site Department of the Army - Fort Gordon Range Control - Directorate of Plans, Training, Mobilization, and Security Location: Aiken, Allendale, and Barnwell Counties, SC., Savannah River Site Contact Person: Donald S. McLean, 706-840-5522 / 706-791-2422 Submitted by Fort Gordon Range Control Training Facility Coordinator (DPTMS) Prepared By: ___________________________________________________________________ Donald S. McLean, Training Facility Coordinator Fort Gordon Georgia Date: 2 Table of Contents Summary, Page 4 Introduction, Page 6 Project Description, Page 6 Purpose and Need for Proposed Action, Page 7

369

[Research at and operation of the material science x-ray absorption beamline (X-11) at the National Synchrotron Light Source]. Progress report  

Science Conference Proceedings (OSTI)

This report discusses three projects at the Material Science X-Ray Absorption Beamline. Topics discussed include: XAFS study of some titanium silicon and germanium compounds; initial XAS results of zirconium/silicon reactions; and low angle electron yield detector.

Not Available

1992-08-01T23:59:59.000Z

370

(Research at and operation of the material science x-ray absorption beamline (X-11) at the National Synchrotron Light Source)  

Science Conference Proceedings (OSTI)

This report discusses three projects at the Material Science X-Ray Absorption Beamline. Topics discussed include: XAFS study of some titanium silicon and germanium compounds; initial XAS results of zirconium/silicon reactions; and low angle electron yield detector.

Not Available

1992-01-01T23:59:59.000Z

371

Description and procedures for synchrotron radiation, small molecule, single crystal crystallography of plutonium complexes at ALS beamline 11.3.1  

E-Print Network (OSTI)

70A prior to transfer to the ALS. The capillary fits snuglyCrystallography of Plutonium Complexes at ALS Beamline11.3.1 (ALS and College of Chemistry Small Molecule

Gorden, A.E.V.; Raymond, K.N.; Shuh, D.K.

2008-01-01T23:59:59.000Z

372

TB-14 Section 3 - Reviews: General Information  

NLE Websites -- All DOE Office Websites (Extended Search)

Preliminary Design (30% completion), Final Design (90%), Construction Readiness, Commissioning Readiness, and Operational Readiness. For a given beamline, these reviews may be...

373

Biological clock  

NLE Websites -- All DOE Office Websites (Extended Search)

Biological clock Biological clock Name: N/A Location: N/A Country: N/A Date: N/A Question: How does a person's biological clock work? Replies: I believe there's a region or gland in the brain that regulates biological clocks. This region or gland senses the environment's day/night cycle. I'm afraid I don't know much more than that. Hope this helps. --- jade No one knows for sure how any circadian (nearly 24 hour-in Latin) clock works. Some interesting facts, though. The pineal gland in the brain is important. Although shifting the day-night cycle can shift the clock, the clock runs on its own without any dark-light cues. So it seems to be a natural chemical clock with a cycle nearly, but not exactly at 24 hours, which is entrained by the 24 hour day-night cycle. There are neurons in lower animals which can be kept alive alone, isolate from the nervous system and from any light-dark cues, that show electrical activity on a near-24-hours cycle

374

Single-crystal Raman spectroscopy and X-ray crystallography at beamline X26-C of the NSLS  

E-Print Network (OSTI)

Three-dimensional structures derived from X-ray diffraction of protein crystals provide a wealth of information. Features and interactions important for the function of macromolecules can be deduced and catalytic mechanisms postulated. Still, many questions can remain, for example regarding metal oxidation states and the interpretation of mystery density, i.e. ambiguous or unknown features within the electron density maps, especially at 2A ? resolutions typical of most macromolecular structures. Beamline X26-C at the

Deborah Stoner-ma; John M. Skinner; Dieter K. Schneider; Matt Cowan; Robert M. Sweet; Allen M. Orville

2010-01-01T23:59:59.000Z

375

Grasshopper Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

Grasshopper Biology Grasshopper Biology Name: s. Location: N/A Country: N/A Date: N/A Question: My son found a grasshopper and put it in a fish bowl with cover, and we need to know what to feed it? we have it some lettuce and apple and a bit of water. Replies: Sounds ok so far, most any kind of green plant should be ok, doubt it will pay too much attention to the water. Don't expect it to live very long though. J. Elliott Hello, Grasshoppers eat green vegetation of various kinds. They especially love tall grass. The greener the better. Clip a variety of plants from a nearby unmowed ditch or vacant lot and place them in a short container of water and place the container of water and plants in your fish bowl. The grasshopper will "eat it up". Wayne Vanderploeg River Trail Nature Center

376

Review of window and filter requirements for commissioning of the Advanced Photon Source insertion device beamlines  

SciTech Connect

The Advanced Photon Source (APS) is building 16 insertion device (ID) front ends for the first phase of the project. Eleven of these are to be equipped with the APS Undulator A and the other five with a Wiggler-A-type source. The Undulator A front ends are designed to operate in a ``windowless`` mode using an APS-designed differential pump. However, during beamline commissioning and early operations of the storage ring, it is prudent to install windows to ensure storage ring vacuum safety before easing into windowless operation. However, the window designed for this interim period may not meet all the needs of a user`s scientific program. In the early phases of the project through commissioning and start of operations, such a window will permit the user to prepare for his program, while allowing both the user and the facility operators to gain experience for safe phasing into eventual windowless operations. In this report, we will present analysis and design options for a variety of windows particularly suited to either the APS Undulator A front ends or as user windows located in the first optics enclosure (FOE).

Kuzay, T.M.; Wang, Zhibi

1994-06-02T23:59:59.000Z

377

The Implementation of a Super Mirror Polarizer at the SNS Fundamental Neutron Physics Beamline  

SciTech Connect

A new bender supermirror polarizer is used to polarize the cold neutron beam at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source. We present the design of a compensation magnet that was built around the polarizer to minimize the polarizer fringe fields that could compromise the magnetic field requirements of the NPDGamma experiment for the field uniformity in the spin rotator and the field direction in the liquid hydrogen target located downstream from the polarizer. The entire magnetic field environment of the experiment has been analyzed using a finite-element model. Measurements of the magnetic field gradients and field direction have been carried out and the results are less than the upper limits required in the experiment. According to the results the compensated fields meet the stringent magnetic field requirements of the experiment defined by the systematic errors that have to be well below the statistical uncertainty of 10 8 in our main observable, the gamma asymmetry in neutron capture on hydrogen. We describe the design of the magnetic field, the construction of the compensation magnet, and we compare results of the field measurements with the results from the model.

Balascuta, S. [Arizona State University; Alarcon, R. [Arizona State University; Baessler, S. [University of Virginia and Oak Ridge National Laboratory (ORNL); Greene, Geoffrey [University of Tennessee, Knoxville (UTK); Mietke, A [Technische Universitat Dresden; Crawford, C. [University of Kentucky, Lexington; Milburn, R. [University of Kentucky, Lexington; Penttila, Seppo [Oak Ridge National Laboratory (ORNL); Prince, J. [University of Virginia, Charlottesville; Schdler, J. [Jacobs University, Bremen, Germany & University of Virginia, Charlottesville

2012-01-01T23:59:59.000Z

378

General Information  

NLE Websites -- All DOE Office Websites (Extended Search)

ASD General Information ASD General Information APS Resources & Information A list of useful links for APS staff and users. APS Technical Publications Links to APS technical publications. APS Publications Database The official and comprehensive source of references for APS-related journal articles, conference papers, book chapters, dissertations, abstracts, awards, invited talks, etc. Image Library A collection of APS images. Responsibilities & Interfaces for APS Technical Systems Descriptions of the responsibilities of APS technical groups and how they interface with one another. APS Procedures Operational procedures for the APS. APS Specifications Specifications and approvals for upgrades or changes to existing APS hardware and software. APS Radiation Safety Policy & Procedures Committee Minutes

379

Lensless Imaging of Whole Biological Cells with Soft X-Rays  

NLE Websites -- All DOE Office Websites (Extended Search)

Lensless Imaging of Whole Biological Cells with Soft X-Rays Print Lensless Imaging of Whole Biological Cells with Soft X-Rays Print A team of scientists has used x-ray diffraction microscopy at ALS Beamline 9.0.1 to make images of whole yeast cells, achieving the highest resolution-11 to 13 nanometers (billionths of a meter)-ever obtained with this method for biological specimens. Their success indicates that full 3-D tomography of whole cells at equivalent resolution should soon be possible. The National Center for X-Ray Tomography at ALS Beamline 2.1 images whole, frozen hydrated cells in 3-D (see highlight "Imaging Antifungal Drug Molecules in Action using Soft X-Ray Tomography"). Large numbers of cells can currently be processed in a short time at resolutions of 40 to 60 nanometers, but the ability to increase resolution to the 10-nanometer range would enhance research capabilities in both biology and materials sciences.

380

Lensless Imaging of Whole Biological Cells with Soft X-Rays  

NLE Websites -- All DOE Office Websites (Extended Search)

Lensless Imaging of Whole Lensless Imaging of Whole Biological Cells with Soft X-Rays Lensless Imaging of Whole Biological Cells with Soft X-Rays Print Wednesday, 26 May 2010 00:00 A team of scientists has used x-ray diffraction microscopy at ALS Beamline 9.0.1 to make images of whole yeast cells, achieving the highest resolution-11 to 13 nanometers (billionths of a meter)-ever obtained with this method for biological specimens. Their success indicates that full 3-D tomography of whole cells at equivalent resolution should soon be possible. The National Center for X-Ray Tomography at ALS Beamline 2.1 images whole, frozen hydrated cells in 3-D (see highlight "Imaging Antifungal Drug Molecules in Action using Soft X-Ray Tomography"). Large numbers of cells can currently be processed in a short time at resolutions of 40 to 60 nanometers, but the ability to increase resolution to the 10-nanometer range would enhance research capabilities in both biology and materials sciences.

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Lensless Imaging of Whole Biological Cells with Soft X-Rays  

NLE Websites -- All DOE Office Websites (Extended Search)

Lensless Imaging of Whole Biological Cells with Soft X-Rays Print Lensless Imaging of Whole Biological Cells with Soft X-Rays Print A team of scientists has used x-ray diffraction microscopy at ALS Beamline 9.0.1 to make images of whole yeast cells, achieving the highest resolution-11 to 13 nanometers (billionths of a meter)-ever obtained with this method for biological specimens. Their success indicates that full 3-D tomography of whole cells at equivalent resolution should soon be possible. The National Center for X-Ray Tomography at ALS Beamline 2.1 images whole, frozen hydrated cells in 3-D (see highlight "Imaging Antifungal Drug Molecules in Action using Soft X-Ray Tomography"). Large numbers of cells can currently be processed in a short time at resolutions of 40 to 60 nanometers, but the ability to increase resolution to the 10-nanometer range would enhance research capabilities in both biology and materials sciences.

382

Lensless Imaging of Whole Biological Cells with Soft X-Rays  

NLE Websites -- All DOE Office Websites (Extended Search)

Lensless Imaging of Whole Biological Cells with Soft X-Rays Print Lensless Imaging of Whole Biological Cells with Soft X-Rays Print A team of scientists has used x-ray diffraction microscopy at ALS Beamline 9.0.1 to make images of whole yeast cells, achieving the highest resolution-11 to 13 nanometers (billionths of a meter)-ever obtained with this method for biological specimens. Their success indicates that full 3-D tomography of whole cells at equivalent resolution should soon be possible. The National Center for X-Ray Tomography at ALS Beamline 2.1 images whole, frozen hydrated cells in 3-D (see highlight "Imaging Antifungal Drug Molecules in Action using Soft X-Ray Tomography"). Large numbers of cells can currently be processed in a short time at resolutions of 40 to 60 nanometers, but the ability to increase resolution to the 10-nanometer range would enhance research capabilities in both biology and materials sciences.

383

Lensless Imaging of Whole Biological Cells with Soft X-Rays  

NLE Websites -- All DOE Office Websites (Extended Search)

Lensless Imaging of Whole Biological Cells with Soft X-Rays Print Lensless Imaging of Whole Biological Cells with Soft X-Rays Print A team of scientists has used x-ray diffraction microscopy at ALS Beamline 9.0.1 to make images of whole yeast cells, achieving the highest resolution-11 to 13 nanometers (billionths of a meter)-ever obtained with this method for biological specimens. Their success indicates that full 3-D tomography of whole cells at equivalent resolution should soon be possible. The National Center for X-Ray Tomography at ALS Beamline 2.1 images whole, frozen hydrated cells in 3-D (see highlight "Imaging Antifungal Drug Molecules in Action using Soft X-Ray Tomography"). Large numbers of cells can currently be processed in a short time at resolutions of 40 to 60 nanometers, but the ability to increase resolution to the 10-nanometer range would enhance research capabilities in both biology and materials sciences.

384

Lensless Imaging of Whole Biological Cells with Soft X-Rays  

NLE Websites -- All DOE Office Websites (Extended Search)

Lensless Imaging of Whole Biological Cells with Soft X-Rays Print Lensless Imaging of Whole Biological Cells with Soft X-Rays Print A team of scientists has used x-ray diffraction microscopy at ALS Beamline 9.0.1 to make images of whole yeast cells, achieving the highest resolution-11 to 13 nanometers (billionths of a meter)-ever obtained with this method for biological specimens. Their success indicates that full 3-D tomography of whole cells at equivalent resolution should soon be possible. The National Center for X-Ray Tomography at ALS Beamline 2.1 images whole, frozen hydrated cells in 3-D (see highlight "Imaging Antifungal Drug Molecules in Action using Soft X-Ray Tomography"). Large numbers of cells can currently be processed in a short time at resolutions of 40 to 60 nanometers, but the ability to increase resolution to the 10-nanometer range would enhance research capabilities in both biology and materials sciences.

385

Lensless Imaging of Whole Biological Cells with Soft X-Rays  

NLE Websites -- All DOE Office Websites (Extended Search)

Lensless Imaging of Whole Biological Cells with Soft X-Rays Print Lensless Imaging of Whole Biological Cells with Soft X-Rays Print A team of scientists has used x-ray diffraction microscopy at ALS Beamline 9.0.1 to make images of whole yeast cells, achieving the highest resolution-11 to 13 nanometers (billionths of a meter)-ever obtained with this method for biological specimens. Their success indicates that full 3-D tomography of whole cells at equivalent resolution should soon be possible. The National Center for X-Ray Tomography at ALS Beamline 2.1 images whole, frozen hydrated cells in 3-D (see highlight "Imaging Antifungal Drug Molecules in Action using Soft X-Ray Tomography"). Large numbers of cells can currently be processed in a short time at resolutions of 40 to 60 nanometers, but the ability to increase resolution to the 10-nanometer range would enhance research capabilities in both biology and materials sciences.

386

Lensless Imaging of Whole Biological Cells with Soft X-Rays  

NLE Websites -- All DOE Office Websites (Extended Search)

Lensless Imaging of Whole Biological Cells with Soft X-Rays Print Lensless Imaging of Whole Biological Cells with Soft X-Rays Print A team of scientists has used x-ray diffraction microscopy at ALS Beamline 9.0.1 to make images of whole yeast cells, achieving the highest resolution-11 to 13 nanometers (billionths of a meter)-ever obtained with this method for biological specimens. Their success indicates that full 3-D tomography of whole cells at equivalent resolution should soon be possible. The National Center for X-Ray Tomography at ALS Beamline 2.1 images whole, frozen hydrated cells in 3-D (see highlight "Imaging Antifungal Drug Molecules in Action using Soft X-Ray Tomography"). Large numbers of cells can currently be processed in a short time at resolutions of 40 to 60 nanometers, but the ability to increase resolution to the 10-nanometer range would enhance research capabilities in both biology and materials sciences.

387

Lensless Imaging of Whole Biological Cells with Soft X-Rays  

NLE Websites -- All DOE Office Websites (Extended Search)

Lensless Imaging of Whole Biological Cells with Soft X-Rays Print Lensless Imaging of Whole Biological Cells with Soft X-Rays Print A team of scientists has used x-ray diffraction microscopy at ALS Beamline 9.0.1 to make images of whole yeast cells, achieving the highest resolution-11 to 13 nanometers (billionths of a meter)-ever obtained with this method for biological specimens. Their success indicates that full 3-D tomography of whole cells at equivalent resolution should soon be possible. The National Center for X-Ray Tomography at ALS Beamline 2.1 images whole, frozen hydrated cells in 3-D (see highlight "Imaging Antifungal Drug Molecules in Action using Soft X-Ray Tomography"). Large numbers of cells can currently be processed in a short time at resolutions of 40 to 60 nanometers, but the ability to increase resolution to the 10-nanometer range would enhance research capabilities in both biology and materials sciences.

388

General Category  

NLE Websites -- All DOE Office Websites (Extended Search)

Jellyfish : Plant or Animal Jellyfish : Plant or Animal Name: Francesca Status: educator Grade: K-3 Location: Outside U.S. Country: USA Date: Spring 2012 Question: Dear Scientist, In our 2nd grade class, we read a story called Jellies. We learned that jellyfish do not have a heart or brain. If they don't, why are they considered an animal and not a plant? How did scientists come to the conclusion that they are NOT plants? Thank you for any information you can give us! Sincerely, Mrs. Holm's Second Graders Replies: Jellyfish move, and they don't make their own food. Plants don't move, and they do (mostly) make their own food. Tim Mooney Francesca Here we are talking about the classification of organisms into taxonomic rank. Since Biology is not my field of expertise, I got the information for your answer from this URL to answer your quest

389

Biology reflective assessment curriculum  

E-Print Network (OSTI)

Penick, J. E. (1998). Biology: A community context. Newof a standards-based high school biology curriculum.The American Biology Teacher Li, J. , Klahr, D. , & Siler,

Bayley, Cheryl Ann

2011-01-01T23:59:59.000Z

390

Biology at Berkeley  

E-Print Network (OSTI)

Paper Series Martin Trow, BIOLOGY AT BERKELEY BibliographyCalifornia, Berkeley. Internal Biology Review Committee. (ishi.lib.berkeley.edu/cshe/ BIOLOGY AT BERKELEY: A Case

Trow, Martin A

1999-01-01T23:59:59.000Z

391

Educational Molecular Biology Games  

NLE Websites -- All DOE Office Websites (Extended Search)

Molecular Biology Games Do you have a great game? Please click our Ideas page. Featured Games: Biology Games fom biologyjunction.com Biology Games fom biologyjunction.com...

392

NEWTON's Molecular Biology Videos  

NLE Websites -- All DOE Office Websites (Extended Search)

Molecular Biology Videos Do you have a great molecular biology video? Please click our Ideas page. Featured Videos: University of Berkeley - Molecular Biology Lectures University...

393

Systems Biology | Clean Energy | ORNL  

NLE Websites -- All DOE Office Websites (Extended Search)

Bioenergy Biological Interfaces Computational Biology and KBase Environmental Biology Genomic Sciences Structural Biology Collaborative University Research Transportation Clean...

394

Biological Science  

NLE Websites -- All DOE Office Websites (Extended Search)

Biological Science Biological Science A unique zinc-binding site revealed by the high-resolution x-ray structure of homotrimeric Apo2L/TRAIL S.G. Hymowitz, M.P. O'Connell, M.H. Ultsch, A. Hurst, K. Totpal, A. Ashkenazi, R.F. Kelley, and A.M. de Vos b-carbonic anhydrase active site architecture is a mirror image of a-carbonic anhydrases E.F. Pai and M.S. Kimber Binding of Cd ions to the cell wall of B. Subtilis - an EXAFS study M. Boyanov, D. Fowle, K. Kemner, B. Bunker, and J. Fein Crystallographic evidence for Try157 functioning as the active site base in human UDP-galactose 4-epimerase J.B. Thoden, T.M. Wohlers, J.L. Fridovich-Keil, and H.M. Holden Crystallographic studies of dsDNA phage HK97 structure and maturation W.R. Wikoff, Z. Che, W. Schildkamp, L. Liljas, R.L. Duda, R.W. Hendrix, and

395

Dose calculations using MARS for Bremsstrahlung beam stops and collimators in APS beamline stations.  

Science Conference Proceedings (OSTI)

The Monte Carlo radiation transport code MARS is used to model the generation of gas bremsstrahlung (GB) radiation from 7-GeV electrons which scatter from residual gas atoms in undulator straight sections within the Advanced Photon Source (APS) storage ring. Additionally, MARS is employed to model the interactions of the GB radiation with components along the x-ray beamlines and then determine the expected radiation dose-rates that result. In this manner, MARS can be used to assess the adequacy of existing shielding or the specifications for new shielding when required. The GB radiation generated in the 'thin-target' of an ID straight section will consist only of photons in a 1/E-distribution up to the full energy of the stored electron beam. Using this analytical model, the predicted GB power for a typical APS 15.38-m insertion device (ID) straight section is 4.59 x 10{sup -7} W/nTorr/mA, assuming a background gas composed of air (Z{sub eff} = 7.31) at room temperature (293K). The total GB power provides a useful benchmark for comparisons between analytical and numerical approaches. We find good agreement between MARS and analytical estimates for total GB power. The extended straight section 'target' creates a radial profile of GB, which is highly peaked centered on the electron beam. The GB distribution reflects the size of the electron beam that creates the radiation. Optimizing the performance of MARS in terms of CPU time per incident trajectory requires the use of a relatively short, high-density gas target (air); in this report, the target density is {rho}L = 2.89 x 10{sup -2} g/cm{sup 2} over a length of 24 cm. MARS results are compared with the contact dose levels reported in TB-20, which used EGS4 for radiation transport simulations. Maximum dose-rates in 1 cc of tissue phantom form the initial basis for comparison. MARS and EGS4 results are approximately the same for maximum 1-cc dose-rates and attenuation in the photon-dominated regions; for thicker targets, however, the dose-rate no longer depends only on photon attenuation, as photoneutrons (PNs) begin to dominate. The GB radiation-induced photoneutron measurements from four different metals (Fe, Cu, W, and Pb) are compared with MARS predictions. The simulated dose-rates for beamline 6-ID are approximately 3-5 times larger than the measured values, whereas those for beamline 11-ID are much closer. Given the uncertainty in local values of pressure and Z, the degree of agreement between MARS and the PN measurements is good. MARS simulations of GB-induced radiation in and around the FOE show the importance of using actual pressure and gas composition (Z{sub eff}) to obtain accurate PN dose. For a beam current of 300 mA, extrapolating pressure data measured in previously published studies predicts an average background gas pressure of 27 nTorr. An average atomic number of Z{sub eff} = 4.0 is obtained from the same studies. In addition, models of copper masks presently in use at the APS are included. Simulations show that inclusion of exit masks make significant differences in both the radiation spatial distribution within the FOE, as well as the peak intensity. Two studies have been conducted with MARS to assess shielding requirements. First, dose levels in contact with the outside wall of the FOE are examined when GB radiation strikes Pb or W beam stops of varying transverse size within the FOE. Four separate phantom regions are utilized to measure the dose, two at beam elevation and two at the horizontal beam position. The first two phantoms are used for scoring FOE dose along the outside and back walls, horizontally; the second two collect dose on the roof and vertically on the back wall. In all cases, the beam stop depth is maintained at 30 cm. Inclusion of front end (FE) exit masks typically cause a 1-2 order-of-magnitude increase in the dose-rates relative to the case with no masks. Masks place secondary bremsstrahlung sources inside the FOE, and therefore they must be shielded appropriately. The MARS model does not fully account for all shielding present

Dooling, J.; Accelerator Systems Division (APS)

2010-11-01T23:59:59.000Z

396

General Category  

NLE Websites -- All DOE Office Websites (Extended Search)

Honeycomb Shape Honeycomb Shape Name: Mew Status: student Grade: 9-12 Location: Outside U.S. Country: Hong Kong Date: Spring 2012 Question: During a biology class, a question popped into my head when we were studying about bees. The question is why are honeycombs only hexagonal in shape and not square or pentagonal in shape? Replies: Hi Mew, In nature, geometry that serves the bees to further multiply will be retained, those geometries that are less able to support formation of more colonies of bees, do not. For bees, which form colonies by swarming, the building must be flexible, compact, resistant to collapse and highly versatile. In terms of natural selection, the hexagon wins out over the square or pentagon in terms of collapse resistance. A hexagon stretched into a column is a hexagonal prism. The strength and stability of the hexagonal prism allows for maximum flex and dissolution of forces from virtually any direction. The hexagonal prisms are able to be tightly packed, called tessellations.

397

Inspector General  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Office of the Under Secretary for Nuclear Security Edward B. Held (Acting) Under Secretary for Nuclear Security DEPARTMENT OF ENERGY Office of the Under Secretary for Management & Performance Vacant Under Secretary for Management and Performance Office of the Under Secretary for Science & Energy Vacant Under Secretary for Science and Energy Southwestern Power Administration Bonneville Power Administration Western Area Power Administration Southeastern Power Administration U.S. Energy Information Administration Loan Programs Office Advanced Research Projects Agency - Energy General Counsel Assistant Secretary for Congressional & Intergovernmental Affairs Chief Human Capital Officer

398

Biology | More Science | ORNL  

NLE Websites -- All DOE Office Websites (Extended Search)

Bioinformatics Nuclear Medicine Climate and Environment Systems Biology Computational Biology Chemistry Engineering Computer Science Earth and Atmospheric Sciences Materials...

399

(Computational) synthetic biology  

Science Conference Proceedings (OSTI)

The ultimate goal of systems biology is the development of executable in silico models of cells and organisms. Systems biology attempts to provide an integrative methodology, which while able to cope with -on the one hand- the data deluge that is being ... Keywords: algorithmic systems biology, executable biology, infobiotics, p systems, synthetic biology, systems biology

Natalio Krasnogor

2011-07-01T23:59:59.000Z

400

General Category  

NLE Websites -- All DOE Office Websites (Extended Search)

Sunrise and Sunset Visual Differences Sunrise and Sunset Visual Differences Name: Joey Status: other Grade: other Country: Canada Date: Spring 2012 Question: It seems that sunrise and sunset don't look symmetric. I mean that sunsets tend to have much redder skies and sunrise is usually a bit gloomier. If you see a picture, many times you can tell if its sunrise or sunset, even though I would think they should like identical, except that the sun is either going up or going down. Why do they not appear the same but in reverse? Replies: Funny you should ask as a paper just arrived which is sure to have the answer and I will read it now....... OK, the morning sky, and the sky in general, is blue due to Rayleigh scattering [which affects short wavelengths the most] of the sun light by air molecules and other microscopic particles.

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Buy Handbook of Chemical and Biological Warfare Agent ...  

U.S. Energy Information Administration (EIA)

Buy Handbook of Chemical and Biological Warfare Agent Decontamination from our Physical Chemistry General range at Tesco direct. We stock a great ...

402

Faculty of Science Biological Sciences  

E-Print Network (OSTI)

on July 1, 2010. California Storm Water BMP Handbook ­ Construction, January 2003 LBNL Surface Water in Bevatron beamline targets, and chromium in the cooling tower. Some of these materials may be present control to remaining active and non-active areas as required by the California Stormwater BMPs Handbook

Auckland, University of

403

Splicing bioinformatics to biology  

E-Print Network (OSTI)

Splicing bioinformatics to biology Douglas L Black* andand Developmental Biology, University of Connecticut Health26 May 2006 Genome Biology 2006, 7:317 (doi:10.1186/gb-2006-

Black, Douglas L; Graveley, Brenton R

2006-01-01T23:59:59.000Z

404

Structural Biology | Biosciences Division  

NLE Websites -- All DOE Office Websites (Extended Search)

Biology BIO Home Page About BIO News Releases Research Publications People Contact Us Organization Chart Site Index Inside BIO BIO Safety About Argonne Structural Biology The...

405

NEWTON's Molecular Biology Archive  

NLE Websites -- All DOE Office Websites (Extended Search)

Molecular Biology Archive: Loading Most Recent Molecular Biology Questions: Cytoplasm pH DNA Extract and Cold Alcohol Albino Gene Loci Male Development Candy and Bacteria Revisited...

406

Computational Biology | Supercomputing & Computation | ORNL  

NLE Websites -- All DOE Office Websites (Extended Search)

Home | Science & Discovery | Supercomputing and Computation | Research Areas | Biology SHARE Computational Biology Computational Biology research encompasses many important...

407

ANL/APS/TB-44, Guidelines for Beamline and Front-End Radiation Shielding Design at the Advanced Photon Source  

NLE Websites -- All DOE Office Websites (Extended Search)

APS/TB-44 Rev. 4 APS/TB-44 Rev. 4 Guidelines for Beamline and Front-End Radiation Shielding Design at the Advanced Photon Source Revision 4 Advanced Photon Source About Argonne National Laboratory Argonne is a U.S. Department of Energy laboratory managed by UChicago Argonne, LLC under contract DE-AC02-06CH11357. The Laboratory's main facility is outside Chicago, at 9700 South Cass Avenue, Argonne, Illinois 60439. For information about Argonne and its pioneering science and technology programs, see www.anl.gov. Availability of This Report This report is available, at no cost, at http://www.osti.gov/bridge. It is also available on paper to the U.S. Department of Energy and its contractors, for a processing fee, from: U.S. Department of Energy Office of Scientific and Technical Information

408

ANL/APS/TB-54, Dose Calculations using MARS for Bremsstrahlung Beam Stops and Collimators in APS Beamline Stations  

NLE Websites -- All DOE Office Websites (Extended Search)

4 4 DOSE CALCULATIONS USING MARS FOR BREMSSTRAHLUNG BEAM STOPS AND COLLIMATORS IN APS BEAMLINE STATIONS Jeffrey C. Dooling Accelerator Systems Division Advanced Photon Source August 2010 This work is sponsored by the US Department of Energy Office of Science The submitted manuscript has been created by UChicago Argonne, LLC, Operator of Argonne National Laboratory ("Argonne"). Argonne, a U.S. Department of Energy Office of Science laboratory, is operated under Contract No. DE-AC02-06CH11357. The U.S. Government retains for itself, and others acting on its behalf, a paid-up nonexclusive, irrevocable worldwide license in said article to reproduce, prepare derivative works, distribute copies to the public, and perform publicly and display

409

High-Energy Nanoscale-Resolution X-ray Microscopy Based on Refractive Optics on a Long Beamline  

Science Conference Proceedings (OSTI)

The long length and good coherence properties of ID11 at the ESRF have led to the development of x-ray microscopy based on compound refractive lenses (CRLs). For the highest resolution full-field microscopy, the sample is placed {approx}40 m from the source, which can be micro-focused by a transfocator as a condenser. Due to the long length of the beamline and consequent long sample-detector distance, a CRL objective can be placed up to a meter behind the sample and still allow for magnification of 60x on a detector located at 99 m--enough to achieve easily 100-nm resolution with a typical high-resolution detector.

Snigireva, I.; Vaughan, G. B. M.; Snigirev, A. [European Synchrotron Radiation Facility (ESRF), 38043 Grenoble (France)

2011-09-09T23:59:59.000Z

410

Textured growth of Co film on CoO (fcc) layer; Structural studies using EDXRD beamline at Indus-2  

SciTech Connect

Co film of 13 nm thickness has been deposited on native oxide (CoO) layer using electron beam evaporation technique. CoO (fcc) of 2.3 nm thickness has been prepared by oxidizing surface of 50 nm thick Co (fcc) by thermal annealing. The structure of the sample has been investigated in detail using in-plane and out-of-plane energy dispersive grazing incidence x-ray diffraction (GIXRD) at EDXRD beamline, Indus-2, RRCAT, Indore. It is found that the growth of the Co film takes place with preferential orientation of c-axis perpendicular to the film plane, which results in structure induced magnetic anisotropy with easy axis normal to the film plane.

Kumar, Dileep; Patidar, P.; Sant, T.; Pandey, K. K.; Gupta, A.; Sharma, S. M. [UGC-DAE Consortium for Scientific Research, University Campus, Khandwa Road, Indore - 452 017 (India); School of Nanotechnology, RGPV, Bhopal-462021 (India); Bhabha Atomic Research Center, Trombay, Mumbai- 400 085 (India); UGC-DAE Consortium for Scientific Research, University Campus, Khandwa Road, Indore - 452 017 (India); Bhabha Atomic Research Center, Trombay, Mumbai- 400 085 (India)

2012-06-05T23:59:59.000Z

411

Molecular Biology DEGREE PROGRAMME  

E-Print Network (OSTI)

BSc (Hons) Molecular Biology DEGREE PROGRAMME GUIDE 2013-2014 #12;BSc (Hons) Molecular Biology - Year 2 - Year 3 - Year 4 Introduction Molecular biology aims to understand living systems by focusing on the molecular components upon which they are built. Molecular biology is one of great successes of 20th century

Siddharthan, Advaith

412

Global warming and biological diversity  

SciTech Connect

This book is based on presentations given at the World Wildlife Fund's Conference on Consequences of the Greenhouse Effect for Biological Diverisity in 1988, and includes updated literature citations. The general topics covered in the book include the following: overview; summary of past responses of plants to climatic change; general ecological and physiological responses; ecosystems in 4 specific regions (arctic marine, Alaskan North Slope, NW US forests, and Mediterranean); global warming's implications for conservation. Ideas and data from many ecosystems and information about the relationships between biodiversity and climatic change are brought together with a balance of factual information and defensible scientific prognostication.

Peters, R.L.; Lovejoy, T.E. (eds.)

1992-01-01T23:59:59.000Z

413

Center for Nanophase Materials Sciences (CNMS) - General Characterizat...  

NLE Websites -- All DOE Office Websites (Extended Search)

neutron scattering facilities that are available at ORNL's High-Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS). Beamlines of particular relevance to CNMS...

414

Biological Sciences at NERSC  

NLE Websites -- All DOE Office Websites (Extended Search)

Biological Sciences Biological Sciences Biological Sciences Better knowledge of biomolecules and processes they undergo is vital for achieving a predictive, systems-level understanding of complex biological systems that have potential use in bioenergy, carbon cycling and biosequestration, and biogeochemistry. Areas that NERSC helps to enable include: Research activities using genomics and systems biology to understand plants and microbes. Developing and applying atomistic-molecular to coarse-grained mathematical models of potential energy surfaces, characterizing these surfaces through sampling techniques and finally generating ensemble or time averaged physical properties of biological phenomena. Fundamental research in the redesign of microbial metabolic processes to harness their potential in the conversion of biomass to

415

2003 Synthetic Biology study  

E-Print Network (OSTI)

Biology is a technology for processing information, materials, and energy. As a technology platform, biological systems provide access to artifacts and processes across a range of scales (e.g., the ribosome is a programmable ...

Endy, Drew

2007-08-14T23:59:59.000Z

416

Biological Production of Hydrogen  

NLE Websites -- All DOE Office Websites (Extended Search)

Biological Techniques Environmental Sampling: Microbial Communities Applications: Algae Ponds Source: Frank Dazzo, Center for Microbial Ecology, Michigan State University...

417

Computational Biology Project  

Science Conference Proceedings (OSTI)

... biological metadata raise questions related to information technology standards ... data/metadata format for image capture, storage, retrieval, analysis; ...

2010-10-05T23:59:59.000Z

418

Biological Interactions and Dynamics  

NLE Websites -- All DOE Office Websites (Extended Search)

State University, Tri-cities, Washington Nitin Baliga, Institute for Systems Biology, Seattle, Washington Jim Frederickson Pacific Northwest National Laboratory,...

419

EUV reflectance characterization of the 94/304 ? flight secondary AIA mirror at beamline 6.3.2 of the Advanced Light Source  

Science Conference Proceedings (OSTI)

The AIA secondary flight mirror, previously coated at Columbia University with Mg/SiC for the 303.8 {angstrom} channel and Mo/Y for the 93.9 {angstrom} channel was characterized by means of EUV reflectance measurements at beamline 6.3.2 of the Advanced Light Source (ALS) synchrotron at LBNL on January 10, 2006. Paul Boerner (LMSAL) also participated in these measurements.

Soufli, R; Spiller, E; Aquila, A L; Gullikson, E M; Windt, D L

2006-02-22T23:59:59.000Z

420

A highly modular beamline electrostatic levitation facility, optimized for in situ high-energy x-ray scattering studies of equilibrium and supercooled liquids  

Science Conference Proceedings (OSTI)

High-energy x-ray diffraction studies of metallic liquids provide valuable information about structural evolution on the atomic length scale, leading to insights into the origin of the nucleation barrier and the processes of supercooling and glass formation. The containerless processing of the beamline electrostatic levitation (BESL) facility allows coordinated thermophysical and structural studies of equilibrium and supercooled liquids to be made in a contamination-free, high-vacuum ({approx}10{sup -8} Torr) environment. To date, the incorporation of electrostatic levitation facilities into synchrotron beamlines has been difficult due to the large footprint of the apparatus and the difficulties associated with its transportation and implementation. Here, we describe a modular levitation facility that is optimized for diffraction studies of high-temperature liquids at high-energy synchrotron beamlines. The modular approach used in the apparatus design allows it to be easily transported and quickly setup. Unlike most previous electrostatic levitation facilities, BESL can be operated by a single user instead of a user team.

Mauro, N.A.; Kelton, K.F. (WU)

2011-10-27T23:59:59.000Z

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Todd Newberry: Professor of Biology  

E-Print Network (OSTI)

Todd Newberry, Professor of Biology: Cowell College page 12Jarrell: Whys that? Todd Newberry, Professor of Biology:Biology Board page 14 Newberry: Well, besides the

Newberry, Andrew Todd; Jarrell, Randall; Regional History Project, UCSC Library

2006-01-01T23:59:59.000Z

422

FGF-23 in bone biology  

E-Print Network (OSTI)

6 REVIEW FGF-23 in bone biology Katherine Wesseling-Perryin impairments in bone biology. Although the defectiveof the protein on bone biology, a growing compendium of data

Wesseling-Perry, Katherine

2010-01-01T23:59:59.000Z

423

Quantitative Imaging in Cell Biology  

E-Print Network (OSTI)

Quantitative! imaging! in! biology! is! concerned! with!Quantitative! imaging! in! biology! is! concerned! with!advances! in! cell! biology! by! enabling! the! tracking!

Yassif, Jaime

2012-01-01T23:59:59.000Z

424

Systems biology approach to bioremediation  

E-Print Network (OSTI)

aspects of the systems biology approach (metagenomics withthe use of a number of sytems biology parameters can revealRL, Banfield JF: Systems Biology: functional analysis of

Chakraborty, R.

2013-01-01T23:59:59.000Z

425

ELECTRON PARAMAGNETIC RESONANCE IN BIOLOGY  

E-Print Network (OSTI)

published in Perspectives in Biology and Medicine. ) 51. D.PARAMAGNETIC RESONANCE IN BIOLOGY G. M. Androes and Melvinparamagnetic resonance in biology is presented, including a

Androes, G.M.; Calvin, Melvin.

2008-01-01T23:59:59.000Z

426

Systems Biology | More Science | ORNL  

NLE Websites -- All DOE Office Websites (Extended Search)

Systems Biology SHARE Systems Biology Caldicellulosiruptor obsidiansis ORNL research is examining life across scales, from the genome to the environment, to find biological...

427

Computational Biology | More Science | ORNL  

NLE Websites -- All DOE Office Websites (Extended Search)

Computational Biology SHARE Computational Biology Computational Biology research encompasses many important aspects including molecular biophysics for bio-energy, genetic level...

428

Draft General Conformity Determination  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

I I Draft General Conformity Determination U.S. Department of the Interior Minerals Management Service MMS Cape Wind Energy Project January 2009 Final EIS Appendix I Draft General Conformity Determination Draft General Conformity Determination Cape Wind Energy Project Prepared by Minerals Management Service Herndon, VA November 2008 i TABLE OF CONTENTS 1.0 INTRODUCTION TO THE PROPOSED ACTION............................................................... 1 2.0 GENERAL CONFORMITY REGULATORY BACKGROUND .......................................... 2 2.1 GENERAL CONFORMITY REQUIREMENTS.................................................................... 2 2.2 GENERAL CONFORMITY APPLICABILITY.....................................................................

429

Biological tracer method  

DOE Patents (OSTI)

The present invention is a biological tracer method for characterizing the movement of a material through a medium, comprising the steps of: introducing a biological tracer comprising a microorganism having ice nucleating activity into a medium; collecting at least one sample of the medium from a point removed from the introduction point; and analyzing the sample for the presence of the biological tracer. The present invention is also a method for using a biological tracer as a label for material identification by introducing a biological tracer having ice nucleating activity into a material, collecting a sample of a portion of the labelled material and analyzing the sample for the presence of the biological tracer. 2 figs.

Strong-Gunderson, J.M.; Palumbo, A.V.

1998-09-15T23:59:59.000Z

430

Biological tracer method  

DOE Patents (OSTI)

The present invention is a biological tracer method for characterizing the movement of a material through a medium, comprising the steps of: introducing a biological tracer comprising a microorganism having ice nucleating activity into a medium; collecting at least one sample of the medium from a point removed from the introduction point; and analyzing the sample for the presence of the biological tracer. The present invention is also a method for using a biological tracer as a label for material identification by introducing a biological tracer having ice nucleating activity into a material, collecting a sample of a portion of the labelled material and analyzing the sample for the presence of the biological tracer.

Strong-Gunderson, Janet M. (Ten Mile, TN); Palumbo, Anthony V. (Oak Ridge, TN)

1998-01-01T23:59:59.000Z

431

NEWTON's General Science Videos  

NLE Websites -- All DOE Office Websites (Extended Search)

General Science Videos Do you have a great general science video? Please click our Ideas page. Featured Videos: Videos from National Geographic Kids Videos from National Geographic...

432

NEWTON's General Science Archive  

NLE Websites -- All DOE Office Websites (Extended Search)

General Science Archive: Loading Most Recent General Science Questions: What is Equilibrium? Banana and Human Genetics Hair Examination Body Buffer Action Jellyfish : Plant or...

433

Biological detector and method  

DOE Patents (OSTI)

A biological detector includes a conduit for receiving a fluid containing one or more magnetic nanoparticle-labeled, biological objects to be detected and one or more permanent magnets or electromagnet for establishing a low magnetic field in which the conduit is disposed. A microcoil is disposed proximate the conduit for energization at a frequency that permits detection by NMR spectroscopy of whether the one or more magnetically-labeled biological objects is/are present in the fluid.

Sillerud, Laurel; Alam, Todd M; McDowell, Andrew F

2013-02-26T23:59:59.000Z

434

BNL Biology Department - Videos  

NLE Websites -- All DOE Office Websites (Extended Search)

Walter Mangel "'Molecular Sleds' and More: Novel Antiviral Agents via Single Molecule Biology," in which he discusses antiviral agents, and in particular, the breakthrough work in...

435

Genomics and Systems Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

such as energy, agriculture, and environmental cleanup. Get Expertise Babetta Marrone Biofuels Program Manager Email Cheryl Kuske DOE BER Biological System Science Division...

436

Biological Materials Science Symposium  

Science Conference Proceedings (OSTI)

The structure and properties of biological materials exhibit a breadth and complexity .... Protective Role of Arapaima Scales: Structure and Mechanical Behavior.

437

Computational Biology | Biosciences Division  

NLE Websites -- All DOE Office Websites (Extended Search)

Computational Biology BIO Home Page About BIO News Releases Research Publications People Contact Us Organization Chart Site Index Inside BIO BIO Safety About Argonne Computational...

438

Structural Biology | Biosciences Division  

NLE Websites -- All DOE Office Websites (Extended Search)

(NIAID) funded program that applies state-of-the-art high-throughput (HTP) structural biology technologies to experimentally characterize the three dimensional atomic structure of...

439

Genomics and Systems Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

Genomics and Systems Biology LANL leads the world in computational finishing of microbial genomes Read caption + In 2013, Los Alamos scientist Richard Sayre and his team...

440

Structural Biology | Biosciences Division  

NLE Websites -- All DOE Office Websites (Extended Search)

Biosciences Division Argonne National Laboratory Biosciences Division > Structural Biology DOE Logo Search BIO ... Search Argonne Home > BIO home > Membrane Protein Engineering >...

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Environmental Biology | Biosciences Division  

NLE Websites -- All DOE Office Websites (Extended Search)

Environmental Biology BIO Home Page About BIO News Releases Research Publications People Contact Us Organization Chart Site Index Inside BIO BIO Safety About Argonne Environmental...

442

Complexity in Biology  

E-Print Network (OSTI)

We will review some of the theoretical progresses that have been in the study of complex systems in physics and of their applications to biology.

Giorgio Parisi

1994-12-05T23:59:59.000Z

443

Ionic electrostatic excitations along biological membranes  

Science Conference Proceedings (OSTI)

A theoretical analysis of ionic electrostatic excitations of a charged biological membrane is presented within the framework of the fluid theory for surface ions inside and outside the cell, in conjunction with the Poisson's equation. General expressions of dispersion relations are obtained for electrostatic oscillations of intrinsic cellular with different shapes and symmetries.

Moradi, Afshin [Department of Nano Science, Kermanshah University of Technology, Kermanshah 67178-63766 (Iran, Islamic Republic of) and Department of Nano Science, Institute for Studies in Theoretical Physics and Mathematics (IPM), Tehran 19395-5531 (Iran, Islamic Republic of)

2011-02-15T23:59:59.000Z

444

Borges Dilemma, Fundamental Laws, and Systems Biology  

E-Print Network (OSTI)

A well-known folk-law in biology is that there is no general law in biology because of exceptions. In her recent elegant essay E.F. Keller gave a particular nice presentation on the exceptions to rules or laws in biology [1]. Her example of scaling laws was especially illuminative. Nevertheless, for this cherished folk-law the present author is wondering about its exceptions, too. Several examples immediately jump into his minds. One, of course, would be the folk-law itself: It had no exception in biology. This would be a bit disappointing because it would only permit us to work as what the cartographers did in J.L. Borges fable [2]. Though eventually a map as big and as detail as the empire itself might be obtained, one would then ask where is the understanding within such an immense object? More disappointedly, such folk-law is really not biological. It has been used by some philosophers to argue against the unity of science [3]. Another example is distinctively biological and would be more exciting, and the author believes its existence should be not surprising to biologists: Evolution by Variation and Selection by Darwin and Wallace. To the authors knowledge this dynamical law has no exception in biology. Nevertheless, under the influence of above folk-law this marvelous dynamics has been named Darwins principle, just falling short to regard it as a fundamental law [4]. Any scientists and mathematicians would know better

Ping Ao

2008-01-01T23:59:59.000Z

445

Uncertain generalized aggregation operators  

Science Conference Proceedings (OSTI)

The aim of this paper is to extend the generalized ordered weighted averaging operator and provide a new class of operators called the uncertain generalized ordered weighted averaging (UGOWA) operator. It provides a very general formulation that includes ... Keywords: Aggregation, Decision making, Generalized mean, OWA operator, Operator weights

Li-Gang Zhou; Hua-You Chen; Jos M. Merig; Anna M. Gil-Lafuente

2012-01-01T23:59:59.000Z

446

Site Map  

NLE Websites -- All DOE Office Websites (Extended Search)

Beamlines Beamlines Directory Beam Status Research Techniques Schedules Photon Source Parameters Storage Ring Parameters News & Publications ALSNews General Publications...

447

BIOISIS: Biological Macromolecules by Small Angle X-ray Scattering (SAXS)  

DOE Data Explorer (OSTI)

BIOISIS is an open access database dedicated to the study of biological macromolecules by small angle X-ray scattering (SAXS). BIOISIS aims to become the complete source for the deposition, distribution and maintenance of small angle X-ray scattering data and technologies. The database is designed around the concept of an experiment and relates a specific experiment to a set of genes, organisms, computational models and experimental data. As of May 2012, BIOSIS contains 7,118 genes covering four different organisms. Forty-two modeled structures are available. Clicking on a structures reveals scattering curves, experimental conditions, and experimental values. The data are collected at Beamline 12.3.1 of the Advanced Light Source (ALS).[Copied with editing from http://www.bioisis.net/about

Tainer, John (Scripps Research Institute); Hura, Greg (LBNL); Rambo, Robert P. (LBNL)

448

Tutorial on biological networks  

Science Conference Proceedings (OSTI)

Understanding how the functioning of a biological system emerges from the interactions among its components is a long-standing goal of network science. Fomented by developments in high-throughput technologies to characterize biomolecules and their interactions, ... Keywords: Biological Data Mining, Data Mining Software Tools, Science and Technology

Francisco G. Vital-Lopez; Vesna Memievi?; Bhaskar Dutta

2012-07-01T23:59:59.000Z

449

Biological sample collector  

DOE Patents (OSTI)

A biological sample collector is adapted to a collect several biological samples in a plurality of filter wells. A biological sample collector may comprise a manifold plate for mounting a filter plate thereon, the filter plate having a plurality of filter wells therein; a hollow slider for engaging and positioning a tube that slides therethrough; and a slide case within which the hollow slider travels to allow the tube to be aligned with a selected filter well of the plurality of filter wells, wherein when the tube is aligned with the selected filter well, the tube is pushed through the hollow slider and into the selected filter well to sealingly engage the selected filter well and to allow the tube to deposit a biological sample onto a filter in the bottom of the selected filter well. The biological sample collector may be portable.

Murphy, Gloria A. (French Camp, CA)

2010-09-07T23:59:59.000Z

450

Optical techniques for detecting and identifying biological-warfare agents  

E-Print Network (OSTI)

Rapid and accurate detection and identification of biological agents is an objective of various national security programs. Detection in general is difficult owing to natural clutter and anticipated low concentrations of ...

Greenwood, Darryl P.

451

General Dynamics, Electric Boat  

Science Conference Proceedings (OSTI)

General Dynamics, Electric Boat. NVLAP Lab Code: 100560-0. Address and Contact Information: 75 Eastern Point Road ...

2013-08-16T23:59:59.000Z

452

Thornridge Biology Home Page  

NLE Websites -- All DOE Office Websites (Extended Search)

How Do We Inherit Our Biological Characteristics How Do We Inherit Our Biological Characteristics How Do We Inherit Our Biological Characteristics? Shelly Peretz Science Department Chairperson Thornridge High School Office Phone: 708-225-4585 speretz@interaccess.com You are visitor Photograph taken from Genetic Pathology Gallery: Cytogenetics, University of Washington Medical Center. Be sure to submit the online sign-off each day. Introduction Individuals, families, health care providers and policymakers face important health care decisions every day. Today, with the growing awareness of the role that genetics plays in our society, decision-making requires more information than ever before. This project uses principles of biology to examine human genetics disorders. Students work in small groups (2-3) on projects which give them the opportunity to understand human

453

Genomics and Systems Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

Genomics and Systems Biology Genomics and Systems Biology Genomics and Systems Biology Los Alamos scientists perform research in functional genomics and structural genomics, and applications for such work cover diverse fields such as energy, agriculture, and environmental cleanup. Get Expertise Babetta Marrone Biofuels Program Manager Email Cheryl Kuske DOE BER Biological System Science Division Program Manager Email Chris Detter Emerging Threats Program Manager: Email Rebecca McDonald Bioscience Communications Email "We were asked to build a rocket ship," said developer Joel Berendzen, "but instead we built a 10,000 mph motorcycle." - Sequedex team LANL leads the world in computational finishing of microbial genomes Protein research Read caption + In 2013, Los Alamos scientist Richard Sayre and his team genetically

454

BNL Biology Department - Publications  

NLE Websites -- All DOE Office Websites (Extended Search)

2003 2002 2001 File Format .pdf 2011 2010 2009 2008 2007 2006 2005 2004 2003 2002 2001 Biology Department 2012 Publications Agarwal R., Burley S.K., and Swaminathan S. Structural...

455

Earthworm Digging Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

Earthworm Digging Biology Name: claire Location: NA Country: NA Date: NA Question: I live in Northeast PA,Monroe County.My husband and I were riding through a State park and saw...

456

Vibrations, Quanta and Biology  

E-Print Network (OSTI)

Quantum biology is an emerging field of research that concerns itself with the experimental and theoretical exploration of non-trivial quantum phenomena in biological systems. In this tutorial overview we aim to bring out fundamental assumptions and questions in the field, identify basic design principles and develop a key underlying theme -- the dynamics of quantum dynamical networks in the presence of an environment and the fruitful interplay that the two may enter. At the hand of three biological phenomena whose understanding is held to require quantum mechanical processes, namely excitation and charge transfer in photosynthetic complexes, magneto-reception in birds and the olfactory sense, we demonstrate that this underlying theme encompasses them all, thus suggesting its wider relevance as an archetypical framework for quantum biology.

S. F. Huelga; M. B. Plenio

2013-06-27T23:59:59.000Z

457

White Ash Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

White Ash Biology Name: blondi Location: NA Country: NA Date: NA Question: 1. Is the white ash tree endangered or is it a protected variety? 2. How does the white ash tree...

458

Saltcedar: Biology and Management  

E-Print Network (OSTI)

Saltcedar is a small tree that causes major problems along rivers in the western half of Texas and throughout the U.S. Southwest. This publication explains its biology and ecological impacts, water use and control strategies.

Hart, Charles R.

2009-05-04T23:59:59.000Z

459

Biology as a career  

NLE Websites -- All DOE Office Websites (Extended Search)

Biology as a career Name: Heather Skeba Location: NA Country: NA Date: NA Question: When I get into the real world I was thinking of being a biologist. How much schooling do you...

460

Tree Frog Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

Tree Frog Biology Name: toreyi Location: NA Country: NA Date: NA Question: My mom transplanted a house cactus and found a frog buried in the soil. We do not want to throw it...

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Bird Feet Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

Bird Feet Biology Name: Jeanne Location: NA Country: NA Date: NA Question: Why don't birds feet freeze during the cold winter months? Replies: I'm not sure about all birds, but...

462

Mourning Dove Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

Mourning Dove Biology Name: Bettina Location: NA Country: NA Date: NA Question: I have found a bird egg. I'm pretty sure it's a morning dove egg. I would like to know how to...

463

Green Biologics | Open Energy Information  

Open Energy Info (EERE)

History Facebook icon Twitter icon Green Biologics Jump to: navigation, search Name Green Biologics Place Oxfordshire, United Kingdom Sector Biomass, Renewable Energy Product...

464

Biological & Environmental Research Abstracts Database  

Office of Scientific and Technical Information (OSTI)

Welcome to the Biological and Environmental Research Abstracts Database The U.S. Department of Energy's Office of Biological and Environmental Research (BER) conducts research in...

465

Structural Biology | Clean Energy | ORNL  

NLE Websites -- All DOE Office Websites (Extended Search)

Structural Biology SHARE Structural Biology ORNL researcher Flora Meilleur prepares protein solutions for structural investigation with neutrons. Source: ORNL Flickr site...

466

SLAC National Accelerator Laboratory - Biology  

NLE Websites -- All DOE Office Websites (Extended Search)

Biology Image of the HIV Antibody moving towards a molecule Biological molecules are the machinery of life. Each year hundreds of scientists come to SLAC's Stanford Synchrotron...

467

Biology Department - Brookhaven National Laboratory  

NLE Websites -- All DOE Office Websites (Extended Search)

Links of Interest Wikipedia (STEM) M.E. Mller-Insitute for Structural Biology National Institute of Biomedical Micoscopy Sosiety of America New York Structural Biology Center...

468

BEAMLINE 13-3  

NLE Websites -- All DOE Office Websites (Extended Search)

EXPERIMENTAL STATION 13-3 EXPERIMENTAL STATION 13-3 CURRENT STATUS Open RESPONSIBLE STAFF Bart Johnson EXPERIMENTS Soft X-ray Coherent Scattering: Resonant, Polarization-dependent; Lensless Imaging: X-ray Holography, MAD phasing; X-ray Photon Correlation Spectroscopy SCHEDULING Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE EPU, Linear and Circular Polarization MONOCHROMATOR SGM, Rowland Circle Spherical Grating 300l/mm 600l/mm 1100l/mm Energy Range 150-400eV 350-750eV 600-1200eV Entrance Slit: 5-20 microns (typical), movable along beam path Exit Slit: 30-100 microns (typical) FOCUSING OPTICS 1313M1 Spherical Mirror, Horizontal Demag. 3:1 133M2 Spherical Mirror, Vertical Demag. 3:2 Spot Size on Sample (min) 24 microns (vertical) x 240 microns (horizontal)

469

Synchrotron Beamline Operations  

Science Conference Proceedings (OSTI)

... of next-generation catalysts for chemical production; optimization of ... of-the-art local structure measurements for electronic, energy, and magnetic ...

2013-07-23T23:59:59.000Z

470

BCDA Beamline Data Visualization  

NLE Websites -- All DOE Office Websites (Extended Search)

use. Pviewer - ASCIIMDA data viewing and report generation package. C Applications MDA Utilities - deals with MDA files created by saveData in EPICS. Valid HTML 4.01 About...

471

BEAMLINE 10-1  

NLE Websites -- All DOE Office Websites (Extended Search)

and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 30-pole, 1.45-Tesla Wiggler ID Side Station BEAM LINE SPECIFICATIONS: energy range grating type resolution...

472

BEAMLINE 4-2  

NLE Websites -- All DOE Office Websites (Extended Search)

100% SCHEDULING: see Proposal Submittal and Scheduling Procedures SOURCE: 8-pole, 1.8-Tesla Wiggler ID End Station OPTICS: Bent cyclinder, silicon, Pt-coated Radii: 1500 m...

473

BEAMLINE 2-3  

NLE Websites -- All DOE Office Websites (Extended Search)

Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 1.3 Tesla Bend Magnet BEAM LINE SPECIFICATIONS: energy range resolution DEE spot size flux...

474

BEAMLINE 11-2  

NLE Websites -- All DOE Office Websites (Extended Search)

and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: 26-pole, 2.0-Tesla Wiggler ID End Station BEAM LINE SPECIFICATIONS: energy range resolution DEE spot...

475

BEAMLINE 13-1  

NLE Websites -- All DOE Office Websites (Extended Search)

mode Sample environment: UHV, Spectroscopy: T 25-450K, magnetic fields up to 0.25 Tesla Microscopy: Room temperature, magnetic fields up to 0.6 Tesla (parallel k) and up to...

476

BEAMLINE 13-2  

NLE Websites -- All DOE Office Websites (Extended Search)

2 2 CURRENT STATUS Open RESPONSIBLE STAFF: Dan Brehmer Hirohito Ogasawara EXPERIMENTS: Photoemission; NEXAFS (see also: Spectroscopic Techniques) SCHEDULING: BL13 Schedules Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules SOURCE: Elliptically polarized undulator OPTICS: M0 vertical deflecting spherical, water-cooled M2 horizontal deflecting spherical M3 vertical deflecting elliptical MONOCHROMATOR: Spherical Grating Monochromator (SGM) SLITS : 0-1000 µm. Entrance slit cooled and movable ± 200 mm along optical axis GRATINGS : 3 water-cooled interchangeable HORIZONTAL ANGULAR ACCEPTANCE : 0.25 mrad ENERGY RANGE : 300 l/mm: 150 - 400 E/DE 10000 600 l/mm: 250 - 700 E/DE 10000 1100 l/mm: 500 - 1200 E/DE 10000 SPOT SIZE : 0.01 x 0.075 mm2

477

Beam-line cryopump  

DOE Green Energy (OSTI)

A cryopumping module using metallic surfaces at liquid helium temperature for condensation of hydrogen and deuterium gas has been constructed. This pump, a prototype of four units which will provide pumping for the Livermore 200 kV test stand, will be used to verify the concept and establish engineering parameters. Upon completion of engineering tests and evaluation the pump will be installed in an operating beam line. The design point pumping capacity is 80,000 liters per second for hydrogen and deuterium at 10$sup -4$ torr based on sticking coefficients of 0.15 and 0.25, respectively. Both the liquid helium temperature pumping surface and the liquid nitrogen temperature radiation shields are constructed of quilted double wall cylindrical shells. The pumping shell dimensions are 1.5 meters dia. x 0.6 meters long. Cryogen circulation is convection current driven in both cases. Liquid helium is supplied from an overhead Dewar through bayonet coupling. In the 200 kV beam line, pumping modules will be supplied via transfer lines from a central Dewar. Voltage standoff will be accomplished in the transfer lines. (auth)

Duffy, T.J.; Oddon, L.D.

1975-11-12T23:59:59.000Z

478

EUV Detector Radiometry Beamline  

Science Conference Proceedings (OSTI)

... The second grating is ruled with 300 lines per millimeter and is ... detector responsivity; filter transmission; uniformity of responsivity or transmission. ...

2011-10-03T23:59:59.000Z

479

Beamline 29-ID  

NLE Websites -- All DOE Office Websites (Extended Search)

Rosenberg Dr. George Srajer IEX - Advisory Committee Dr Dario Arena (Brookhaven National Lab, NSLS) Dr. Steve Hulbert (Brookhaven National Lab, NSLS) Dr Zahid Hussain...

480

NYSBC MICRODIFFRACTION BEAMLINE  

NLE Websites -- All DOE Office Websites (Extended Search)

, W .A. H endrickson 1,2,3 , J .P. L idestri 1,2 , Q . L iu 1 , J . S chwanof 1 , X . Y ang 1 1 New Y ork S tructural B iology C enter, 2 Columbia U niversity, 3 Brookhaven N...

Note: This page contains sample records for the topic "biology general beamline" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Beamline XX-XX  

NLE Websites -- All DOE Office Websites (Extended Search)

sign here (if applicable): Level I operator SDL Operation (X.J. Wang (x5791)) Manuals and DUV-FEL documentation location http:www.nsls.bnl.govorganizationAccelerator...

482

BCDA Beamline Controls Hardware  

NLE Websites -- All DOE Office Websites (Extended Search)

progress. Feature sheets tell you what the part is and what it does. Quick reference manuals are intended to show the important information on the part, such as commonly used...

483

Genomes, Phylogeny, and Evolutionary Systems Biology  

E-Print Network (OSTI)

tested by synthetic biology (de novo design of biologicalEVOLUTIONARY SYSTEMS BIOLOGY MNICA MEDINA *, Department of45639 characters Systems biology is in the eye of the

Medina, Monica

2005-01-01T23:59:59.000Z

484

Report of The Structural Biology Subcommittee of The Biological and  

Office of Science (SC) Website

Report of The Structural Biology Subcommittee of The Report of The Structural Biology Subcommittee of The Biological and Environmental Research Advisory Committee Biological and Environmental Research Advisory Committee (BERAC) BERAC Home Meetings Members Charges/Reports Current BERAC Charges Archive of BERAC Reports Charter .pdf file (40KB) BER Committees of Visitors BER Home Charges/Reports Report of The Structural Biology Subcommittee of The Biological and Environmental Research Advisory Committee Print Text Size: A A A RSS Feeds FeedbackShare Page REPORT of the STRUCTURAL BIOLOGY SUBCOMMITTEE of the BIOLOGICAL AND ENVIRONMENTAL RESEARCH ADVISORY COMMITTEE In response to the charge letter of Dr. Martha Krebs, May 28, 1998 Executive Summary Structural biology and especially macromolecular crystallography are playing an increasingly important role in biological discoveries. In order

485

7th Annual Systems Biology Symposium: Systems Biology and Engineering  

DOE Green Energy (OSTI)

Systems biology recognizes the complex multi-scale organization of biological systems, from molecules to ecosystems. The International Symposium on Systems Biology has been hosted by the Institute for Systems Biology in Seattle, Washington, since 2002. The annual two-day event gathers the most influential researchers transforming biology into an integrative discipline investingating complex systems. Engineering and application of new technology is a central element of systems biology. Genome-scale, or very small-scale, biological questions drive the enigneering of new technologies, which enable new modes of experimentation and computational analysis, leading to new biological insights and questions. Concepts and analytical methods in engineering are now finding direct applications in biology. Therefore, the 2008 Symposium, funded in partnership with the Department of Energy, featured global leaders in "Systems Biology and Engineering."

Galitski, Timothy P.

2008-04-01T23:59:59.000Z

486

DOE General Competencies  

Energy.gov (U.S. Department of Energy (DOE))

The DOE General Competencies are the personal and professional attributes that are critical to successful performance. A competency model is a collection of competencies that together define...

487

Photon Generalized Parton Distributions  

E-Print Network (OSTI)

We present a calculation of the generalized parton distributions of the photon using overlaps of photon light-front wave functions.

Asmita Mukherjee; Sreeraj Nair

2011-09-30T23:59:59.000Z

488

Photon Generalized Parton Distributions  

E-Print Network (OSTI)

We present a calculation of the generalized parton distributions of the photon using overlaps of photon light-front wave functions.

Mukherjee, Asmita

2011-01-01T23:59:59.000Z

489

1998 EMC: General Information  

Science Conference Proceedings (OSTI)

For information regarding the DRC, please contact Emmanuel Crabb, DRC General Meeting Chair, IBM SRDC, MS-E40, Building 630, 1580 Route 52,...

490

General Employee Radiological Training  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE HANDBOOK GENERAL EMPLOYEE RADIOLOGICAL TRAINING U.S. Department of Energy AREA TRNG Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution...

491

Biotic prognostications: Global warming and biological diversity  

SciTech Connect

This book focuses on the impacts of the greenhouse effect on biological diversity and on natural ecosystems. Included are chapters which include the following topics: government attitudes to climate change problems; general conclusions and deficiencies of general circulation models; impacts of past climate changes on global biota; effects of climate on vegetation, soils, wildlife diversity, animal physiology, ecology, behavior, migration, and parasites and diseases; arctic mariene ecosystems and coasta marine zones; tropical forests; arctic tundra; western North American forests, etc.; indirect linkages and snyergisms among climate change, biodiversity, geosphere, and anthropogenic stresses.

Peters, R.L.; Lovejoy, T.E. [eds.

1992-12-31T23:59:59.000Z

492

NUFinancials General Ledger  

E-Print Network (OSTI)

NUFinancials General Ledger Reference TroubleshootingGuide Last Updated 11/24/2012 mac © 2010 Northwestern University FMS711 Corrections, Sales, and Transfers Page 1 of 5 Troubleshooting Actuals Journals;NUFinancials General Ledger Reference TroubleshootingGuide Last Updated 11/24/2012 mac © 2010 Northwestern

Shull, Kenneth R.