Powered by Deep Web Technologies
Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Thermal Waters Along The Konocti Bay Fault Zone, Lake County, California- A  

Open Energy Info (EERE)

Waters Along The Konocti Bay Fault Zone, Lake County, California- A Waters Along The Konocti Bay Fault Zone, Lake County, California- A Re-Evaluation Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Thermal Waters Along The Konocti Bay Fault Zone, Lake County, California- A Re-Evaluation Details Activities (3) Areas (1) Regions (0) Abstract: The Konocti Bay fault zone (KBFZ), initially regarded by some as a promising target for liquid-dominated geothermal systems, has been a disappointment. At least five exploratory wells were drilled in the vicinity of the KBFZ, but none were successful. Although the Na-K-Ca and Na-Li geothermometers indicate that the thermal waters discharging in the vicinity of Howard and Seigler Springs may have equilibrated at temperatures greater than 200°C, the spring temperatures and fluid

2

Landsat TM processing in the investigation of active fault zones, South Lajas Valley Fault Zone and Cerro Goden Fault Zone as an example  

E-Print Network [OSTI]

unrecognized east- west trending fault crossing an alluvial fan on the southern side of the Lajas Valley, SWLandsat TM processing in the investigation of active fault zones, South Lajas Valley Fault Zone and geophysical data, to delineate the lateral extent of two fault zones, the South Lajas Valley Fault Zone (SLVFZ

Gilbes, Fernando

3

Development of a Hydrologic Characterization Technology for Fault Zones Final Report  

E-Print Network [OSTI]

Hydrologic Characterization Technology of Fault Zones, Phaseof Characterization Technology for Fault Zones, LBNL-1635E,Characterization on Technology of Fault Zones – Phase II

Karasaki, Kenzi

2014-01-01T23:59:59.000Z

4

E-Print Network 3.0 - active fault zone Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Earth Structure (2nd Edition), 2004 Summary: 292010 Oceanic Transform Faults and Fracture Zones Transform Fault: Active displacement. Fracture Zone: Fossil... fault, no active...

5

Mechanical properties and fabric of the Punchbowl fault zone, California  

E-Print Network [OSTI]

, and 50 to 125'C, in the presence of pore fluids. The fault zone and surrounding rock consists of (1) the main gouge zone, separated from (2) the undeformed host-rack, by (3) an irregular zone of damaged host-rock. The subsidiary fault fabric... orientations of discrete shear surfaces within the gouge 52 14 Photographs of subsidiary faults within the damaged zone of the Punchbowl Formation. . . . . . 57 15 Photomicrographs showing the progressive increase in deformation of the Punchbowl Formation...

Chester, Frederick Michael

2012-06-07T23:59:59.000Z

6

PREEARTHQUAKE AND POSTEARTHQUAKE CREEP ON THE IMPERIAL FAULT AND THE BRAWLEY FAULT ZONE1  

E-Print Network [OSTI]

(Goulty and others, 1978). The 1979 Imperial Valley earthquake was associated with surface faultingPREEARTHQUAKE AND POSTEARTHQUAKE CREEP ON THE IMPERIAL FAULT AND THE BRAWLEY FAULT ZONE1 By STEPHEN, and 2 years ofsurveys from two nail files suggests that creep events on the Imperial fault 2 to 5 months

Tai, Yu-Chong

7

Stress and fault rock controls on fault zone hydrology, Coso geothermal  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Stress and fault rock controls on fault zone hydrology, Coso geothermal field, CA Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: Stress and fault rock controls on fault zone hydrology, Coso geothermal field, CA Details Activities (1) Areas (1) Regions (0) Abstract: In crystalline rock of the Coso Geothermal Field, CA, fractures are the primary source of permeability. At reservoir depths, borehole image, temperature, and mud logs indicate fluid flow is concentrated in extensively fractured damage zones of large faults well-oriented for slip.

8

Interseismic deformation and geologic evolution of the Death Valley Fault Zone  

E-Print Network [OSTI]

Interseismic deformation and geologic evolution of the Death Valley Fault Zone Cecilia Del Pardo,1 Valley Fault Zone (DVFZ), located in southeastern California, is an active fault system with an evolved motion and long-term stress accumulation rates to better understand the nature of both past and present

Blewitt, Geoffrey

9

Locating an active fault zone in Coso geothermal field by analyzing...  

Open Energy Info (EERE)

production and injection drilling, since an active fault zone often acts as a fracture-extensive low-velocity wave guide to seismic waves. We have located an active fault...

10

Locating an active fault zone in Coso geothermal field by analyzing seismic  

Open Energy Info (EERE)

Locating an active fault zone in Coso geothermal field by analyzing seismic Locating an active fault zone in Coso geothermal field by analyzing seismic guided waves from microearthquake data Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: Locating an active fault zone in Coso geothermal field by analyzing seismic guided waves from microearthquake data Details Activities (1) Areas (1) Regions (0) Abstract: Active fault systems usually provide high-permeability channels for hydrothermal outflow in geothermal fields. Locating such fault systems is of a vital importance to plan geothermal production and injection drilling, since an active fault zone often acts as a fracture-extensive low-velocity wave guide to seismic waves. We have located an active fault zone in the Coso geothermal field, California, by identifying and analyzing

11

Modeling fault-zone guided waves of microearthquakes in a geothermal  

Open Energy Info (EERE)

fault-zone guided waves of microearthquakes in a geothermal fault-zone guided waves of microearthquakes in a geothermal reservoir Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Modeling fault-zone guided waves of microearthquakes in a geothermal reservoir Details Activities (1) Areas (1) Regions (0) Abstract: Fault-zone guided waves have been identified in microearthquake seismograms recorded at the Coso Geothermal Field, California. The observed guided waves have particle motions and propagation group velocities similar to Rayleigh wave modes. A numerical method has been employed to simulate the guided-wave propagation through the fault zone. By comparing observed and synthetic waveforms the fault-zone width and its P- and S-wave velocity structure have been estimated. It is suggested here that the identification

12

Thermal Waters Along The Konocti Bay Fault Zone, Lake County...  

Open Energy Info (EERE)

thermal waters along the KBFZ contain >100 mgl Mg. High concentrations of dissolved magnesium are usually indicative of relatively cool hydrothermal systems. Dissolution of...

13

Deformation of Compliant Fault Zones Induced by Nearby Earthquakes: Theoretical Investigations in Three Dimensions and Applications to The East California Shear Zone  

E-Print Network [OSTI]

primarily examine the plastic strain distribution within the fault zone and the displacement field that characterizes the effects of the presence of the fault zone. I find that when the fault zone rocks are close to failure in the prestress field, plastic...

Kang, Jingqian

2014-02-21T23:59:59.000Z

14

The Nootka Fault Zone — a new plate boundary off western Canada  

Science Journals Connector (OSTI)

......a graben structure forming the northern extension of West Valley, the present active spreadingcentre of the Juan de Fuca...projection of the fault zone neverthelessclosely encompasses West Valley, the active western segment of the twin spreading valleys......

R. D. Hyndman; R. P. Riddihough; R. Herzer

1979-09-01T23:59:59.000Z

15

Modeling fault-zone guided waves of microearthquakes in a geothermal...  

Open Energy Info (EERE)

the identification and modeling of such guided waves is an effective tool to locate fracture-induced, low-velocity fault-zone structures in geothermal fields. Authors Lou, M.;...

16

Hydrogeological aspects of fault zones on various scales in the Roer Valley Rift System  

E-Print Network [OSTI]

at the location of the fault zone. Finally, on a regional scale, hydraulic head patterns around the lignite mining to regional groundwater flow patterns. D 2003 Elsevier Science B.V. All rights reserved. Keywords: Faults B.V. All rights reserved. doi:10.1016/S0375-6742(03)00031-1 * Corresponding author. Fax: +31

Bense, Victor

17

Pull-Apart in Strike-Slip Fault Zone | Open Energy Information  

Open Energy Info (EERE)

Pull-Apart in Strike-Slip Fault Zone Pull-Apart in Strike-Slip Fault Zone Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Pull-Apart in Strike-Slip Fault Zone Dictionary.png Pull-Apart in Strike-Slip Fault Zone: No definition has been provided for this term. Add a Definition Pull-aparts form in strike-slip fault zones. Arrows indicate direction of slip. (reference: http://myweb.cwpost.liu.edu/vdivener/notes/cont_transform.htm) Faulds uses this term as a structural control found in the Basin and Range province of the US. 4% of all Great Basin geothermal systems are located in pull-aparts but are more abundant within or along the margins of the Walker Lane. (reference: http://www.atlasgeoinc.com/wp-content/uploads/GRC2011-Faulds.pdf). Retrieved from "http://en.openei.org/w/index.php?title=Pull-Apart_in_Strike-Slip_Fault_Zone&oldid=599541"

18

Modeling tip zones to predict the throw and length characteristics of faults  

SciTech Connect (OSTI)

A map of faults in a 60 km{sup 2} area of the southern North Sea has been produced from three-dimensional seismic data. The faults shown on the map obey power-law cumulative-frequency distributions for throw (power-law exponent, D, {approx} 2.7) and length (D {approx} 1.1). Simulations have been carried out to correct for sampling biases in the data and to make predictions of the throw the data and to make predictions of the throw and length scaling characteristics of the faults. The most important bias is caused by poor resolution of the small displacement tip zones of faults. The raw data show considerable scatter in their length: throw ratios, but they more closely fit a linar relationship if a length of 500 m is added to each fault, thereby making up for the zones near the fault tips with throws ({approx} 15 m) below seismic resolution. Further variability in the data may be caused by such geological factors as fault interaction. Tip lengths have been extended to simulate the actual fault pattern in the study area. Maps produced by this procedure can be used to estimate the true connectivity of the fault network. Extending the faults results in greater connectivity than shown by the raw data, which may cause greater compartmentalization of the rock mass. This greater compartmentalization has implications for hydrocarbon exploitation if the faults are sealing. A problem with the model, however, is that it does not deal effectively with the interaction of subparallel, noncoplanar faults. To test the reliability of the procedure, we analyzed exposure-scale faults in Somerset, United Kingdom, where the tips are well constrained. Both length-throw relationships and map-pattern connectivity for the simulated fault networks agree closely with the actual data.

Pickering, G.; Sanderson, D.J.; Bull, J.M. [Univ. of Southampton (United Kingdom)] [and others

1997-01-01T23:59:59.000Z

19

Slip zone and energetics of a large earthquake from the Taiwan Chelungpu-fault Drilling Project  

E-Print Network [OSTI]

LETTERS Slip zone and energetics of a large earthquake from the Taiwan Chelungpu-fault Drilling) at or near the surface2 , which is accessible to borehole drilling and provides a rare opportunity to sample . The actual thickness of the zone that slips dur- ing the rupture of a large earthquake is not known

Ma, Kuo-Fong

20

Seismic reflection imaging of the Mount Rose fault zone, Reno, Nevada  

E-Print Network [OSTI]

Seismic reflection imaging of the Mount Rose fault zone, Reno, Nevada Project Award Number: # G09AP expressed or implied, of the U.S. Government. #12;2 Abstract Five new high-resolution seismic reflection00071 Submission date: November 30, 2010 CGISS Technical Report 10-01 Lee M. Liberty Center

Barrash, Warren

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Low fault friction in Iran implies localized deformation for the ArabiaEurasia collision zone  

E-Print Network [OSTI]

Low fault friction in Iran implies localized deformation for the Arabia­Eurasia collision zone P velocity field of the present-day deformation in Iran is modeled using a 3-dimensional (3D) finite element of the kinematics in Iran, but the complex velocity field of the surrounding South Caspian basin cannot be fitted

Vernant, Philippe

22

Textural evidence for recent co-seismic circulation of fluids in the Nojima fault zone, Awaji island, Japan  

E-Print Network [OSTI]

. These carbonate-filled fractures are interpreted as the result of co-seismic hydraulic fracturing and upward very late in the evolution of the fault zone, and may be induced by co-seismic hydraulic fracturing.V. Keywords: Active fault; Co-seismic hydraulic fracturing; Fluid circulation; Carbonate infilling 0040

Demouchy, Sylvie

23

E-Print Network 3.0 - andreas fault zone Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Chester Summary: accommodated along large plate-boundary faults like the San Andreas transform fault in California. These faults... depend in part on the structure of the tabular...

24

Heterogeneous slip and rupture models of the San Andreas fault zone based upon three-dimensional earthquake tomography  

SciTech Connect (OSTI)

Crystal fault zones exhibit spatially heterogeneous slip behavior at all scales, slip being partitioned between stable frictional sliding, or fault creep, and unstable earthquake rupture. An understanding the mechanisms underlying slip segmentation is fundamental to research into fault dynamics and the physics of earthquake generation. This thesis investigates the influence that large-scale along-strike heterogeneity in fault zone lithology has on slip segmentation. Large-scale transitions from the stable block sliding of the Central 4D Creeping Section of the San Andreas, fault to the locked 1906 and 1857 earthquake segments takes place along the Loma Prieta and Parkfield sections of the fault, respectively, the transitions being accomplished in part by the generation of earthquakes in the magnitude range 6 (Parkfield) to 7 (Loma Prieta). Information on sub-surface lithology interpreted from the Loma Prieta and Parkfield three-dimensional crustal velocity models computed by Michelini (1991) is integrated with information on slip behavior provided by the distributions of earthquakes located using, the three-dimensional models and by surface creep data to study the relationships between large-scale lithological heterogeneity and slip segmentation along these two sections of the fault zone.

Foxall, W.

1992-11-01T23:59:59.000Z

25

Geomechanical effects on CO{sub 2} leakage through fault zones during large-scale underground injection  

SciTech Connect (OSTI)

The importance of geomechanics—including the potential for faults to reactivate during large scale geologic carbon sequestration operations—has recently become more widely recognized. However, notwithstanding the potential for triggering notable (felt) seismic events, the potential for buoyancy-driven CO{sub 2} to reach potable groundwater and the ground surface is actually more important from public safety and storage-efficiency perspectives. In this context, this work extends the previous studies on the geomechanical modeling of fault responses during underground carbon dioxide injection, focusing on the short-term integrity of the sealing caprock, and hence on the potential for leakage of either brine or CO{sub 2} to reach the shallow groundwater aquifers during active injection. We consider stress/strain-dependent permeability and study the leakage through the fault zone as its permeability changes during a reactivation, also causing seismicity. We analyze several scenarios related to the volume of CO{sub 2} injected (and hence as a function of the overpressure), involving both minor and major faults, and analyze the profile risks of leakage for different stress/strain-permeability coupling functions. We conclude that whereas it is very difficult to predict how much fault permeability could change upon reactivation, this process can have a significant impact on the leakage rate. Moreover, our analysis shows that induced seismicity associated with fault reactivation may not necessarily open up a new flow path for leakage. Results show a poor correlation between magnitude and amount of fluid leakage, meaning that a single event is generally not enough to substantially change the permeability along the entire fault length. Consequently, even if some changes in permeability occur, this does not mean that the CO{sub 2} will migrate up along the entire fault, breaking through the caprock to enter the overlying aquifer.

Rinaldi, A.P.; Rutqvist, J.; Cappa, F.

2013-09-01T23:59:59.000Z

26

Relationship between the PC and AL indices during repetitive bay-like magnetic disturbances in the auroral zone  

Science Journals Connector (OSTI)

To study the relations of the polar cap (PC) magnetic activity (characterized by the PC index) to magnetic disturbances in the auroral zone (AL index) the behavior of 62 repetitive bay-like magnetic disturbances has been analyzed. It was found that the PC index, derived as a proxy of the geoeffective interplanetary electric field Em, starts to increase, on average, about 30 min ahead of the magnetic disturbance onset. Value of Em and PC?2 mV/m seems to be necessary for development of the repetitive bay-like disturbances with peak AL exceeding 400 nT. Growth phase duration (the time interval between the start of PC increase and AL sudden onset) and intensity of magnetic disturbances in the auroral zone (AL max) highly correlate with the PC growth rate. The growth phase reduces to a few minutes, if the PC index suddenly jumps above ?6–8 mV/m. The sharp development of Birkeland current wedge during expansion phase insignificantly influences the polar cap activity: the corresponding PC index increase does not exceed 10–20% of the PC value. It is concluded that the PC index may be considered as a convenient proxy of the solar wind energy input into the magnetosphere.

O. Troshichev; A. Janzhura

2009-01-01T23:59:59.000Z

27

Stepover or Relay Ramp in Normal Fault Zones | Open Energy Information  

Open Energy Info (EERE)

Multiple intersections between the overlapping fault strands results in increased fracture density that enhances hydrothermal fluid flow. Other definitions:Wikipedia Reegle...

28

Extractable organic material in fault zones as a tool to1 investigate frictional stress2  

E-Print Network [OSTI]

by measuring modern heat flow in boreholes in the vicinity of the San Andreas37 Fault [Brune et al., 1969 the temperature of a fault immediately after a large earthquake [Kano et al., 2006;44 Tanaka et al., 2001], however, no project to date has succeeded in drilling fast and deep enough45 with sufficient repeated

Polissar, Pratigya J.

29

Structure and tectonics of the Sumatra Fault Zone-Sundra Trench junction  

E-Print Network [OSTI]

. The objective of this study is to determine the structures of the Sunda Strait forearm region, the south - southeast continuation of the Sumatra Fault, and model the tectonic development. All available geophysical data for the Sunda Strait forearm region have...

Handayani, Lina

2012-06-07T23:59:59.000Z

30

Characteristics of displacement transfer zones associated with thrust faults / by Arthur Francis Xavier O'Keefe  

E-Print Network [OSTI]

thrust fault in Upper Allan Mountain. Sketch from outcrop showing location of bedding planes with thin (less than 0. 5 cm) layer of' appsz'ent gouge material developed. 36 17 Idealized hypothetical strike section of two thzust fault s showing... stratigraphic column is not necessary and a working stratigraphy, less detailed. than that of Mudge (1972a) was used (Figure 3). No important lateral strati- graphic variations were seen in the thesis area. The lowest unit mapped is the Allan Mountain...

O'Keefe, Arthur Francis Xavier

2012-06-07T23:59:59.000Z

31

Neogene to Quaternary tectonics of the Garlock Fault and the Eastern California shear zone in the northern Mojave Desert, California  

E-Print Network [OSTI]

Neogene to Quaternary tectonics of the Garlock Fault and the Eastern California shear zone in the northern Mojave Desert, California By Copyright 2012 William Michael Rittase B.S. University of North Carolina at Chapel Hill, 2004 M... & The Southern Slate Range Figure 3.4 Structural & Stratigraphic Cross-Sections A-A’, B-B’, C-C’ & D-D’ Figure 3.5 Generalized East-West Stratigraphic Cross-Section Through Northern Pilot Knob Valley Figure 3.6 Annotated Field Photographs Of Pilot Knob...

Rittase, William Michael

2012-12-31T23:59:59.000Z

32

Predicting fault damage zones by modeling dynamic rupture propagation and comparison  

E-Print Network [OSTI]

faults observed in the SSC reservoir. The modeling of ruptures propagating as self-sustaining pulses, Stanford University, Stanford, California, USA, 2 Now at Upstream Technology, BP America, Houston, Texas University, Houston, California, USA, 4 ConocoPhillips Technology and Projects, Houston, Texas, USA Abstract

Dunham, Eric M.

33

Grain-scale Comminution and Alteration of Arkosic Rocks in the Damage Zone of the San Andreas Fault at SAFOD  

E-Print Network [OSTI]

is cut by numerous subsidiary faults that display extensive evidence of repeating episodes of compaction, shear, dilation, and cementation. The subsidiary faults are grouped into three size classes: 1) small faults, 1 to 2 mm thick, that record an early...

Heron, Bretani

2012-02-14T23:59:59.000Z

34

Role of temperature change in micro seismic activity during fluid injections in faulted and fractured zones. Part 1: Updating the thermal modelling in a  

E-Print Network [OSTI]

Role of temperature change in micro seismic activity during fluid injections in faulted and fractured zones. Part 1: Updating the thermal modelling in a DFN model using a double media approach Ahmed) or at comparisons of tracer and thermal transport in fractured reservoirs (Juliusson et Horne, 2010) to investigate

Paris-Sud XI, Université de

35

Western limits of the Seattle fault zone and its interaction with the Olympic Peninsula, Washington  

E-Print Network [OSTI]

deformation zone. Newly acquired high- resolution seismic reflection and marine magnetic data suggest A.P. Lamb1 , L.M. Liberty1 , R.J. Blakely2 , T.L. Pratt3 , B.L. Sherrod3 , and K. van Wijk1 1

Boise State University

36

Analysis of the influence of the normal zone propagation velocity on the design of resistive fault current limiters  

Science Journals Connector (OSTI)

Commercial high-temperature superconducting coated conductors (HTS-CCs) have low thermal diffusivity and nonuniform critical current density. These two factors lead commercial HTS-CCs to a partial quench when they are subjected to a transport current around their average critical current (). The consequence is the appearance of localized resistive zones, and a high risk of thermal runaway can arise when HTS-CCs are used for resistive fault current limiter (RFCL) purposes. The enhancement of the normal zone propagation velocity (NZPV) of HTS-CCs is a desirable solution for achieving sufficient thermal stability while keeping the cost of RFCLs under an acceptable threshold. Even though in recent years, several valid methods to increase the NZPV have been proposed, their impact on the design of RFCLs is not clear. For this reason, we developed a one-dimensional numerical model that enables us to simulate HTS-CCs with enhanced NZPV and to study the limitation performance of a HTS-CC-based RFCL in real operating conditions. Our preliminary re sults demonstrate that the NZPV enhancement can effectively limit the needed amount of HTS-CCs with important economic benefits for the design of RFCLs.

Daniele Colangelo; Bertrand Dutoit

2014-01-01T23:59:59.000Z

37

Trapping capacity of fault zones, downdip Yegua Formation, Texas Gulf Coast basin  

E-Print Network [OSTI]

PROCEDURES. 25 Methods of Measurement Conversion to Mercury/Air System. . Sample Preparation. SHEARED ZONE EVALUATIONS. . 27 31 32 34 Introduction. Cities Service Dincans I Well (CD I). General Crude Kirby Lumber 2 Well (GCK2). . . . Texture...). . . . . . . . . . . . . . . . 23 10 Mercury injection cell apparatus for measurement of capillary pressure (Keelan, 1982) 28 11 Centrifugal apparatus for capillary pressure tests (Keelan, 1982). . . 30 12 Plot of porosity with depth for the total cored interval of interest...

Hintz, Jena Christine

2012-06-07T23:59:59.000Z

38

Extractable organic material in fault zones as a tool to investigate frictional stress Pratigya J. Polissar a,  

E-Print Network [OSTI]

in boreholes in the vicinity of the San Andreas Fault (Brune et al., 1969; Lachenbruch and Sass, 1980; 1992 the temperature of a fault immediately after a large earthquake (Kano et al., 2006; Tanaka et al., 2001), however, no project to date has succeeded in drilling fast and deep enough with sufficient repeated measurements

Polissar, Pratigya J.

39

Accommodation Zone | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Accommodation Zone Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Accommodation Zone Dictionary.png Accommodation Zone: Accommodation zones occur at fault intersections consisting of belts of interlocking, oppositely dipping normal faults. Multiple subsurface fault intersections in these zones are a favorable host for geothermal activity. Other definitions:Wikipedia Reegle Controlling Structures List of controlling structures typically associated with geothermal systems: Major Normal Fault Termination of a Major Normal Fault Stepover or Relay Ramp in Normal Fault Zones

40

Scales Depencence of Fracture Density and Fabric in the Damage Zone of a Large Displacement Continental Transform Fault  

E-Print Network [OSTI]

image (XPL) of the same thin section. .............................................................. 49 Figure 7. Linear transgranular fracture density variation relative to distance from the large mesoscale subsidiary fault (SF, blue line) located... at 3062.5 m MD shown in the wrap-around maps of the Phase 1 core (Figure 5). ...................... 50 Figure 8. Linear intragranular fracture density variation relative to distance from the large mesoscale subsidiary fault (SF, blue line) located...

Ayyildiz, Muhammed

2012-08-28T23:59:59.000Z

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Major Normal Fault | Open Energy Information  

Open Energy Info (EERE)

Major Normal Fault Major Normal Fault Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Major Normal Fault Dictionary.png Major Normal Fault: Normal faults are structures in which the hanging wall is down dropped along the fault plane relative to the foot wall. They are the predominant type of structure in extensional tectonic environments, but are commonly encountered in a number of geologic settings. Other definitions:Wikipedia Reegle Controlling Structures List of controlling structures typically associated with geothermal systems: Major Normal Fault Termination of a Major Normal Fault Stepover or Relay Ramp in Normal Fault Zones Apex or Salient of Normal Fault Fault Intersection Accommodation Zone Displacement Transfer Zone Pull-Apart in Strike-Slip Fault Zone

42

Fault Intersection | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Fault Intersection Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Fault Intersection Dictionary.png Fault Intersection: Fault intersections are junctions between normal faults and either transversely oriented strike-slip or oblique-slip faults. Subsurface fluid flow in these areas is enhanced by multiple minor faults that connect the major intersecting structures, forming highly fractured zones or dilational quadrants with increased permeability. Other definitions:Wikipedia Reegle Controlling Structures List of controlling structures typically associated with geothermal

43

Apex or Salient of Normal Fault | Open Energy Information  

Open Energy Info (EERE)

Apex or Salient of Normal Fault Apex or Salient of Normal Fault Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Apex or Salient of Normal Fault Dictionary.png Apex or Salient of Normal Fault: Normal faults may intersect in the subsurface to form a fault apex or salient. Apices or salients of normal faults account for 3% of structural controls in the Great Basin. Other definitions:Wikipedia Reegle Controlling Structures List of controlling structures typically associated with geothermal systems: Major Normal Fault Termination of a Major Normal Fault Stepover or Relay Ramp in Normal Fault Zones Apex or Salient of Normal Fault Fault Intersection Accommodation Zone Displacement Transfer Zone Pull-Apart in Strike-Slip Fault Zone Intrusion Margins and Associated Fractures Stratigraphic Boundaries

44

Displacement Transfer Zone | Open Energy Information  

Open Energy Info (EERE)

Displacement Transfer Zone Displacement Transfer Zone Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Displacement Transfer Zone Dictionary.png Displacement Transfer Zone: Displacement transfer zones facilitate the transfer of strain between normal and strike-slip faults. Intersections between strike-slip faults in the Walker Lane and N- to NNE-striking normal faults commonly host geothermal systems, focused along the normal faults proximal to their dilational intersections with nearby strike-slip faults. Other definitions:Wikipedia Reegle Controlling Structures List of controlling structures typically associated with geothermal systems: Major Normal Fault Termination of a Major Normal Fault Stepover or Relay Ramp in Normal Fault Zones Apex or Salient of Normal Fault

45

Hydrothermal brecciation in the Jemez Fault zone, Valles Caldera, New Mexico: Results from CSDP (Continental Scientific Drilling Program) corehole VC-1  

SciTech Connect (OSTI)

Paleozoic and Precambrian rocks intersected deep in Continental Scientific Drilling Program corehole VC-1, adjacent to the late Cenozoic Valles caldera complex, have been disrupted to form a spectacular breccia sequence. The breccias are of both tectonic and hydrothermal origin, and probably formed in the Jemez fault zone, a major regional structure with only normal displacement since mid-Miocene. Tectonic breccias are contorted, crushed, sheared, and granulated; slickensides are commmon. Hydrothermal breccias, by contrast, lack these frictional textures, but arej commonly characterized by fluidized matrix foliation and prominent clast rounding. Fluid inclusions in the hydrothermal breccias are dominantly two-phase, liquid-rich at room temperature, principally secondary, and form two distinctly different compositional groups. Older inclusions, unrelated to brecciation, are highly saline and homogenize to the liquid phase in the temperature range 189 to 246/sup 0/C. Younger inclusions, in part of interbreccia origin, are low-salinity and homogenize (also to liquid) in the range 230 to 283/sup 0/C. Vapor-rich inclusions locally trapped along with these dilute liquid-rich inclusions document periodic boiling. These fluid-inclusion data, together with alteration assemblages and textures as well as the local geologic history, have been combined to model hydrothermal brecciation at the VC-1 site.

Hulen, J.B.; Nielson, D.L.

1987-06-01T23:59:59.000Z

46

Bay Marchand revisited (again): Field development using the latest technology  

SciTech Connect (OSTI)

Low-risk well recompletion and side-track opportunities are identified within the Bay Marchand-Timbalier Bay salt complex using 3D depth migration and multi-dimensional reservoir characterization technology. In 1992 Neomar Resources hit pay zones in 12 out of 14 wells located over amplitude anomalies ({open_quotes}bright spots{close_quotes}) in a proprietary 3D survey covering all or part of Bay Marchand Block 1-5. Production from several of these wells has been disappointing, however, and problems with structural position, trap integrity, and reservoir continuity are not obvious in the 3D time migrated data. Zydeco Exploration has obtained a license and has re-processed the Bay Marchand seismic survey in-house using interactive 3D velocity analysis and 3D pre-stack and post-stack depth migration. The new data reveal systematic changes in the positions of faults and smaller reservoirs that account for structural problems, such as missed objectives, and premature pressure depletion in several of the wells. Interpretation of the depth migrated data, seismic attribute analysis of 12 Miocene reservoirs, and multi-dimensional visual correlation and geo-statistical analysis between seismic attributes and log petrophysical data yields a reliable reservoir quality classification scheme within the 3D survey area. Reservoir classification color schemes overlain on their respective horizon surfaces in the presence of fault planes and salt surfaces in a dynamic 3D display reveals reservoir continuity or trap integrity problems which account for disappointing production in several of the wells. Surface enhancement techniques highlight subtle lineations that may also indicate reservoir compartmentalization. Improved structural imaging and reservoir characterization provide more than 20-20 hindsight. We have identified several relatively low-risk recompletions, sidetrack opportunities and proposed well locations.

McTigue, J.W. Jr.; Knecht, S.W.

1995-12-31T23:59:59.000Z

47

Investigation of active faulting at the Emigrant Peak fault in Nevada using shallow seismic reflection and ground penetrating radar  

E-Print Network [OSTI]

The objective of this study was to assess fault displacement, off-fault deformation, and alluvial fan stratigraphy at the Emigrant Peak fault zone (EPFZ) in Fish Lake Valley, Nevada utilizing shallow seismic reflection (SSR) and ground penetrating...

Christie, Michael Wayne

2007-12-18T23:59:59.000Z

48

Neotectonics of Panama. I. Major fault systems  

SciTech Connect (OSTI)

The direction and rate of relative plate motion across the Caribbean-Nazca boundary in Panama is poorly known. This lack of understanding can be attributed to diffuse seismicity; lack of well constrained focal mechanisms from critical areas; and dense tropical vegetation. In order to better understand the relation of plate motions to major fault systems in Panama, the authors have integrated geologic, remote sensing, earthquake and UTIG marine seismic reflection data. Three areas of recent faulting can be distinguished in Panama and its shelf areas; ZONE 1 of eastern Panama consists of a 70 km wide zone of 3 discrete left-lateral strike-slip faults (Sanson Hills, Jaque River, Sambu) which strike N40W and can be traced as continuous features for distances of 100-150 km; ZONE 2 in central Panama consists of a diffuse zone of discontinuous normal(.) faults which range in strike from N40E, N70E; ZONE 3 in western Panama consists of a 60 km wide zone of 2 discrete, left-lateral(.) strike-slip faults which strike N60W and can be traced as continuous features for distances of 150 km; ZONE 3 faults appear to be continuous with faults bounding the forearc Teraba Trough of Costa Rica. The relation of faults of ZONE 3 to faults of ZONE 2 and a major fault bounding the southern Panama shelf is unclear.

Corrigan, J.; Mann, P.

1985-01-01T23:59:59.000Z

49

Subsurface geology of Corpus Christi Bay, Neuces County, Texas  

SciTech Connect (OSTI)

Prolific production in Corpus Christi Bay has occurred mainly in the regressive Frio Barrier Bar System and the associated shore face-shelf environment. All production in Corpus Christi Bay area is below the Anahuac transgressive wedge with the greatest accumulation in the 1st Marg. sand, which has produced a minimum of 680 BCF of gas in the Red Fish Bay-Mustang Island Common 10 reservoir, the largest single reservoir in South Texas. The 1st Marg. sands have produced in excess of 990 BCFG from four fields in Corpus Christi Bay. Shallow hydrocarbons in Corpus Christi Bay are associated with the South Texas Frio Barrier Bar System and are structurally trapped on large fault bound anticlines or up-to-the-coast relief faults. Deeper production from the Frio Sands is mainly on the Barrier Bar shoreface and associated with fault bounded anticlinal closures. Structural complexity increases with depth especially along the large strike aligned growth faults, some up to 4000 ft displacement, and the associated rollover anticlines. subsidiary faults, and shale plugs. These deeper reservoirs are usually pressure-depletion drives. The oil industry can point with pride to the co-existence with the fragile bay environment while extracting huge reserves. Most of the wells are on State of Texas marine leases and are controlled by State rules and City of Corpus Christi Bay drilling ordinances.

Collins, J.W.

1996-09-01T23:59:59.000Z

50

Fault finder  

DOE Patents [OSTI]

A fault finder for locating faults along a high voltage electrical transmission line. Real time monitoring of background noise and improved filtering of input signals is used to identify the occurrence of a fault. A fault is detected at both a master and remote unit spaced along the line. A master clock synchronizes operation of a similar clock at the remote unit. Both units include modulator and demodulator circuits for transmission of clock signals and data. All data is received at the master unit for processing to determine an accurate fault distance calculation.

Bunch, Richard H. (1614 NW. 106th St., Vancouver, WA 98665)

1986-01-01T23:59:59.000Z

51

Gas, liquids flow rates hefty at Galveston Bay discovery  

SciTech Connect (OSTI)

Extended flow tests indicate a large Vicksburg (Oligocene) gas, condensate, and oil field is about to be developed in western Galveston Bay. Internal estimates indicates that ultimate recovery from the fault block in which the discovery well was drilled could exceed 1 tcf of gas equivalent of proved, possible, and probable reserves. The paper discusses the test program for this field and other prospects in the Galveston Bay area.

Petzet, G.A.

1998-01-19T23:59:59.000Z

52

Continuity conditions for a fault consisting of obliquely aligned cracks  

E-Print Network [OSTI]

by the ambient stress, and other regions that are open and ¯uid- or air-®lled (e.g. Nagy 1992). The fault may as a ¯uid conduit or a seal depending on the fault zone complexity or microstructural details (Jones & Knipe 1996). Therefore, prediction of the fault seal potential is important. One way to characterize

Cambridge, University of

53

Seismoelectric Imaging of a Shallow Fault System Employing Fault Guided Waves  

E-Print Network [OSTI]

Independent sets of reflection seismic and seismoelectric data were collected, processed, and interpreted with the aim of generating and studying guided waves within a fault zone. While seismic surveys have recently been utilized to investigate...

Cohrs, Frelynn Joseph Reese

2012-07-16T23:59:59.000Z

54

SLIP ALONG THE SAN ANDREAS FAULT ASSOCIATED WITH THE EARTHQUAKE1  

E-Print Network [OSTI]

Imperial Valley earthquake occurred along other than the Imperial fault and the Brawley fault zone. More in the static- strain field that accompanied the earthquake. At about the same time in the 1979 Imperial Valley, similar behavior of the Imperial fault before 1979 suggests that this section ofthe San Andreas fault may

Tai, Yu-Chong

55

From mechanical modeling to seismic imaging of faults: A synthetic workflow to study the impact of faults on seismic  

Science Journals Connector (OSTI)

Abstract Although typically interpreted as 2D surfaces, faults are 3D narrow zones of highly and heterogeneously strained rocks, with petrophysical properties differing from the host rock. Here we present a synthetic workflow to evaluate the potential of seismic data for imaging fault structure and properties. The workflow consists of discrete element modeling (DEM) of faulting, empirical relations to modify initial acoustic properties based on volumetric strain, and a ray-based algorithm simulating prestack depth migration (PSDM). We illustrate the application of the workflow in 2D to a 100 m displacement normal fault in a kilometer size sandstone-shale sequence at 1.5 km depth. To explore the effect of particle size on fault evolution, we ran two DEM simulations with particle assemblages of similar bulk mechanical behavior but different particle size, one with coarse (1–3 m particle radii) and the other with fine (0.5–1.5 m particle radii) particles. Both simulations produce realistic but different fault geometries and strain fields, with the finer particle size model displaying narrower fault zones and fault linkage at later stages. Seismic images of these models are highly influenced by illumination direction and wave frequency. Specular illumination highlights flat reflectors outside the fault zone, but fault related diffractions are still observable. Footwall directed illumination produces low amplitude images. Hanging wall directed illumination images the shale layers within the main fault segment and the lateral extent of fault related deformation. Resolution and the accuracy of the reflectors are proportional to wave frequency. Wave frequencies of 20 Hz or more are necessary to image the different fault structure of the coarse and fine models. At 30–40 Hz, there is a direct correlation between seismic amplitude variations and the input acoustic properties after faulting. At these high frequencies, seismic amplitude variations predict both the extent of faulting and the changes in rock properties in the fault zone.

Charlotte Botter; Nestor Cardozo; Stuart Hardy; Isabelle Lecomte; Alejandro Escalona

2014-01-01T23:59:59.000Z

56

Physiochemical Evidence of Faulting Processes and Modeling of Fluid in Evolving Fault Systems in Southern California  

SciTech Connect (OSTI)

Our study targets recent (Plio-Pleistocene) faults and young (Tertiary) petroleum fields in southern California. Faults include the Refugio Fault in the Transverse Ranges, the Ellwood Fault in the Santa Barbara Channel, and most recently the Newport- Inglewood in the Los Angeles Basin. Subsurface core and tubing scale samples, outcrop samples, well logs, reservoir properties, pore pressures, fluid compositions, and published structural-seismic sections have been used to characterize the tectonic/diagenetic history of the faults. As part of the effort to understand the diagenetic processes within these fault zones, we have studied analogous processes of rapid carbonate precipitation (scaling) in petroleum reservoir tubing and manmade tunnels. From this, we have identified geochemical signatures in carbonate that characterize rapid CO2 degassing. These data provide constraints for finite element models that predict fluid pressures, multiphase flow patterns, rates and patterns of deformation, subsurface temperatures and heat flow, and geochemistry associated with large fault systems.

Boles, James [Professor

2013-05-24T23:59:59.000Z

57

digital circuit patch bay  

Science Journals Connector (OSTI)

A patch bay in which low-level digital data circuits may be patched, monitored, and tested. Note: The digital circuit patch bay may be either (a) a...See also circuit ...

2001-01-01T23:59:59.000Z

58

Observations on Faults and Associated Permeability Structures in Hydrogeologic Units at the Nevada Test Site  

SciTech Connect (OSTI)

Observational data on Nevada Test Site (NTS) faults were gathered from a variety of sources, including surface and tunnel exposures, core samples, geophysical logs, and down-hole cameras. These data show that NTS fault characteristics and fault zone permeability structures are similar to those of faults studied in other regions. Faults at the NTS form complex and heterogeneous fault zones with flow properties that vary in both space and time. Flow property variability within fault zones can be broken down into four major components that allow for the development of a simplified, first approximation model of NTS fault zones. This conceptual model can be used as a general guide during development and evaluation of groundwater flow and contaminate transport models at the NTS.

Prothro, Lance B.; Drellack, Sigmund L.; Haugstad, Dawn N.; Huckins-Gang, Heather E.; Townsend, Margaret J.

2009-03-30T23:59:59.000Z

59

Characterization of the structure of faults in the Eocene Carrizo Formation near Gause, Milam County, Texas  

E-Print Network [OSTI]

-scale graben accommodating NW-SE extension. The Carrizo Fm. consists primarily of friable to weakly lithified quartz sandstones with several horizons with interbedded siltstones and shales. Five faults and fault zones occur in the quarry with displacements...

Yilmaz, Ramazan

2012-06-07T23:59:59.000Z

60

Thermo-and hydro-mechanical processes along faults during rapid slip  

E-Print Network [OSTI]

Thermo- and hydro-mechanical processes along faults during rapid slip James R. Rice & Eric M micro-contacts, and (2) Thermal pressurization of fault-zone pore fluid. Both have characteristics which

Dunham, Eric M.

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Lost lake - restoration of a Carolina bay  

SciTech Connect (OSTI)

Carolina bays are shallow wetland depressions found only on the Atlantic Coastal Plain. Although these isolated interstream wetlands support many types of communities, they share the common features of having a sandy margin, a fluctuating water level, an elliptical shape, and a northwest to southeast orientation. Lost Lake, an 11.3 hectare Carolina bay, was ditched and drained for agricultural production before establishment of the Savannah River Site in 1950. Later it received overflow from a seepage basin containing a variety of chemicals, primarily solvents and some heavy metals. In 1990 a plan was developed for the restoration of Lost Lake, and restoration activities were complete by mid-1991. Lost Lake is the first known project designed for the restoration and recovery of a Carolina bay. The bay was divided into eight soil treatment zones, allowing four treatments in duplicate. Each of the eight zones was planted with eight species of native wetland plants. Recolonization of the bay by amphibians and reptiles is being evaluated by using drift fences with pitfall traps and coverboard arrays in each of the treatment zones. Additional drift fences in five upland habitats were also established. Hoop turtle traps, funnel minnow traps, and dip nets were utilized for aquatic sampling. The presence of 43 species common to the region has been documented at Lost Lake. More than one-third of these species show evidence of breeding populations being established. Three species found prior to the restoration activity and a number of species common to undisturbed Carolina bays were not encountered. Colonization by additional species is anticipated as the wetland undergoes further succession.

Hanlin, H.G.; McLendon, J.P. [Univ. of South Carolina, Aiken, SC (United States). Dept. of Biology and Geology; Wike, L.D. [Univ. of South Carolina, Aiken, SC (United States). Dept. of Biology and Geology; [Westinghouse Savannah River Co., Aiken, SC (United States). Savannah River Technology Center; Dietsch, B.M. [Univ. of South Carolina, Aiken, SC (United States). Dept. of Biology and Geology; [Univ. of Georgia, Aiken, SC (United States)

1994-09-01T23:59:59.000Z

62

Stress and fault rock controls on fault zone hydrology, Coso...  

Open Energy Info (EERE)

regions of distinct fluid inclusion chemistry and temperature gradient. Distributed fracture networks play only a minor role in fluid flow despite locally high fracture density...

63

Definition: Displacement Transfer Zone | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Displacement Transfer Zone Jump to: navigation, search Dictionary.png Displacement Transfer Zone Displacement transfer zones facilitate the transfer of strain between normal and strike-slip faults. Intersections between strike-slip faults in the Walker Lane and N- to NNE-striking normal faults commonly host geothermal systems, focused along the normal faults proximal to their dilational intersections with nearby strike-slip faults.[2] View on Wikipedia Wikipedia Definition References ↑ James E. Faulds,Nicholas H. Hinz,Mark F. Coolbaugh,Patricia H. Cashman,Christopher Kratt,Gregory Dering,Joel Edwards,Brett Mayhew,Holly McLachlan. 2011. Assessment of Favorable Structural Settings of Geothermal

64

Bay Area | Open Energy Information  

Open Energy Info (EERE)

Bay Area Bay Area Jump to: navigation, search Contents 1 Clean Energy Clusters in the Bay Area 1.1 Products and Services in the Bay Area 1.2 Research and Development Institutions in the Bay Area 1.3 Networking Organizations in the Bay Area 1.4 Investors and Financial Organizations in the Bay Area 1.5 Policy Organizations in the Bay Area Clean Energy Clusters in the Bay Area Products and Services in the Bay Area Loading map... {"format":"googlemaps3","type":"ROADMAP","types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"limit":500,"offset":0,"link":"all","sort":[""],"order":[],"headers":"show","mainlabel":"","intro":"","outro":"","searchlabel":"\u2026

65

Analysis of the growth of strike-slip faults using effective medium theory  

SciTech Connect (OSTI)

Increases in the dimensions of strike-slip faults including fault length, thickness of fault rock and the surrounding damage zone collectively provide quantitative definition of fault growth and are commonly measured in terms of the maximum fault slip. The field observations indicate that a common mechanism for fault growth in the brittle upper crust is fault lengthening by linkage and coalescence of neighboring fault segments or strands, and fault rock-zone widening into highly fractured inner damage zone via cataclastic deformation. The most important underlying mechanical reason in both cases is prior weakening of the rocks surrounding a fault's core and between neighboring fault segments by faulting-related fractures. In this paper, using field observations together with effective medium models, we analyze the reduction in the effective elastic properties of rock in terms of density of the fault-related brittle fractures and fracture intersection angles controlled primarily by the splay angles. Fracture densities or equivalent fracture spacing values corresponding to the vanishing Young's, shear, and quasi-pure shear moduli were obtained by extrapolation from the calculated range of these parameters. The fracture densities or the equivalent spacing values obtained using this method compare well with the field data measured along scan lines across the faults in the study area. These findings should be helpful for a better understanding of the fracture density/spacing distribution around faults and the transition from discrete fracturing to cataclastic deformation associated with fault growth and the related instabilities.

Aydin, A.; Berryman, J.G.

2009-10-15T23:59:59.000Z

66

Fault Mapping At Raft River Geothermal Area (1993) | Open Energy  

Open Energy Info (EERE)

Fault Mapping At Raft River Geothermal Area (1993) Fault Mapping At Raft River Geothermal Area (1993) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Fault Mapping At Raft River Geothermal Area (1993) Exploration Activity Details Location Raft River Geothermal Area Exploration Technique Fault Mapping Activity Date 1993 Usefulness useful DOE-funding Unknown Exploration Basis Geologic mapping, strain and kinematic analysis Notes The mountains expose a detachment fault that separates a hanging wall of Paleozoic rocks from Proterozoic and Archean rocks of the footwall. Beneath the detachment lies a 100 to 300m-thick top-to-the-east extensional shear zone. Geologic mapping, strain and kinematic analysis, and 40Ar/39Ar thermochronology suggest that the shear zone and detachment fault had an

67

Tidal Computations for Morecambe Bay  

Science Journals Connector (OSTI)

......Numerical model for storm surges in Galveston Bay, Proc. Am. S. Civil Eng...computation of two hurricane surges in Galveston Bay, Texas. Sielecki & Wurtele (1970...Numerical model for storm surges in Galveston Bay, Proc. Am. S. Civil Eng......

R. A. Flather; N. S. Heaps

1975-08-01T23:59:59.000Z

68

Software fault avoidance issues  

Science Journals Connector (OSTI)

This article aims to discuss various issues of software fault avoidance. Software fault avoidance aims to produce fault free software through various approaches having the common objective of reducing the number of latent defects in software programs.

Goutam Kumar Saha

2006-11-01T23:59:59.000Z

69

Upper crustal faulting in an obliquely extending orogen, structural control  

Open Energy Info (EERE)

faulting in an obliquely extending orogen, structural control faulting in an obliquely extending orogen, structural control on permeability and production in the Coso Geothermal Field, eastern California Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: Upper crustal faulting in an obliquely extending orogen, structural control on permeability and production in the Coso Geothermal Field, eastern California Details Activities (1) Areas (1) Regions (0) Abstract: New multifold seismic reflection data from the Coso geothermal field in the central Coso Range, eastern California, image brittle faults and other structures in a zone of localized crustal extension between two major strike-slip faults. The Coso Wash fault, a Quaternary-active normal fault that is a locus of surface geothermal activity, is well-imaged as a

70

Controlled-source electromagnetic mapping of a faulted sandstone aquifer in central Texas  

E-Print Network [OSTI]

across a fault (Randolph 1991), due to permeability reduction in the deformation zone, but in some cases can be enhanced along the fault slip plane (Antonellini and Aydin 1994), i. e. parallel to the fault. A knowledge of subsurface fault distributions... the electromagnetic response. Seaborne et al. (1979) interpreted the anomalies as the edge effect of thin horizontal sheets of low resistivity beds, as opposed to the high conductivity response of the material in a fault zone. In a similar study, Hazell er al...

Gorman, Erin Margaret

2012-06-07T23:59:59.000Z

71

Definition: Accommodation Zone | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Accommodation Zone Jump to: navigation, search Dictionary.png Accommodation Zone Accommodation zones occur at fault intersections consisting of belts of interlocking, oppositely dipping normal faults. Multiple subsurface fault intersections in these zones are a favorable host for geothermal activity.[2] View on Wikipedia Wikipedia Definition References ↑ James E. Faulds,Nicholas H. Hinz,Mark F. Coolbaugh,Patricia H. Cashman,Christopher Kratt,Gregory Dering,Joel Edwards,Brett Mayhew,Holly McLachlan. 2011. Assessment of Favorable Structural Settings of Geothermal Systems in the Great Basin, Western USA. In: Transactions. GRC Anual Meeting; 2011/10/23; San Diego, CA. Davis, CA: Geothermal Resources

72

Geometry and development of relay ramps in normal fault systems  

SciTech Connect (OSTI)

Normal fault zones play a major role in the development of basins and in the migration and trapping of hydrocarbons. The mapping of normal fault systems using seismic data requires careful correlation of faults on adjacent sections, a procedure that often leads to the interpretation of faults as having long, continuous, sinuous traces. Recent work involving detailed mapping of fault traces, first by using land exposures but more recently using three-dimensional seismics, has demonstrated that faults are usually made up of many overstepping segments, linked by areas of complex deformation, termed transfer zones or relay ramps. Relay ramps occur between normal fault segments that overstep in map view. The geometry and evolution of exposure-scale relay ramps are described from the Somerset coast, England, and are compared with larger scale ramps from elsewhere. Relay ramps can be classified into four groups based on the degree of interaction and linkage between the overstepping segments; these groups are interpreted as being evolutionary stages. In stage 1, the segments do not interact. Stage 2 involves the reorientation of bedding between two interacting faults to produce a relay ramp. In stage 3, connecting fractures start to break the relay ramp. Stage 4 is when the relay ramp is destroyed to produce a single fault that has an along-strike bend. These evolutionary stages can develop through time, but they can also be seen spatially. A branch line between normal faults or an along-strike bend may represent a stage 4 relay, with progressively earlier stages occurring updip or downdip. Characteristic variability in displacement-distance profiles for fault segments and linked faults accompanies the interaction and linkage processes. Displacement transfer by relay ramps is accompanied by steep displacement gradients along fault segments at oversteps. Relay ramps often contribute to a minimum in total fault displacement at a linkage point. 47 refs., 16 figs.

Peacock, D.C.P. (Univ. of Southampton (United Kingdom) Univ. of Plymouth, Devon (United Kingdom)); Sanderson, D.J. (Univ. of Southampton (United Kingdom))

1994-02-01T23:59:59.000Z

73

Displacement and segment linkage in fracture zones  

SciTech Connect (OSTI)

Fault zones and vein arrays are composed of overstepping and linked segments, so knowledge of segment evolution is crucial in understanding the development of zones. Displacement-distance profiles of faults and veins are used to study the development of segments and zones. Detailed mapping of normal and strike-slip faults allows comparison of the displacement-distance characteristics of faults both normal and parallel to the displacement vector, i.e. modes III and II propagation respectively. Similarly, vein width variations can be used to study mode I propagation. Displacement varies with distance along fractures, with zero displacement at fracture tips. Steep displacement gradients can occur where faults and extension fractures overstep because of displacement transfer between the segments. This displacement transfer is accommodated by relay and bridge structures. Overstepping fractures may link to form a single fracture with an irregular displacement-distance profile. A linkage point is often marked by a bend with a displacement minimum, where relay/bridge structures are preserved as normal drag. Displacement variations are also caused by fault bends, conjugate relationships and by lithological variations. As interaction between fractures increases, r/d[sub MAX] ratios tend to decrease (where r = the distance between the tip and the point of maximum displacement, and d[sub MAX] = maximum displacement). As a result of the interaction of fracture segments, fracture zones tend to have complex displacement-distance profiles.

Peacock, D.C.P.; Sanderson, D.J. (Univ. of Southampton (United Kingdom). Dept. of Geology)

1992-01-01T23:59:59.000Z

74

The hunt for theta13 at the Daya Bay nuclear power plant  

E-Print Network [OSTI]

The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight "identical" antineutrino detectors to measure antineutrino fluxes from six 2.9 GW_{th} reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ~0.38% using current experimental techniques. Daya Bay can reach a sensitivity of <0.01 to $sin^2 2theta_{13}$ with baseline uncertainties after 3 years of data taking.

Wei Wang; for the Daya Bay collaboration

2009-10-23T23:59:59.000Z

75

The hunt for theta13 at the Daya Bay nuclear power plant  

E-Print Network [OSTI]

The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight "identical" antineutrino detectors to measure antineutrino fluxes from six 2.9 GW_{th} reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ~0.38% using current experimental techniques. Daya Bay can reach a sensitivity of <0.01 to $sin^2 2theta_{13}$ with baseline uncertainties after 3 years of data taking.

Wang, Wei

2009-01-01T23:59:59.000Z

76

digital primary patch bay  

Science Journals Connector (OSTI)

A patch bay that provides (a) the first ... in a technical control facility and (b) patching, monitoring, and testing capabilities for both...Common abbreviation DPPB. Note: The digital ci...

2001-01-01T23:59:59.000Z

77

K-patch bay  

Science Journals Connector (OSTI)

A patching facility designed for patching and monitoring balanced digital data circuits, i...?1) (Mbps, Mb/s, Mb/sec) Synonym K-type patch bay. See also balance ...

2001-01-01T23:59:59.000Z

78

Active Faulting in the Coso Geothermal Field, Eastern California | Open  

Open Energy Info (EERE)

Faulting in the Coso Geothermal Field, Eastern California Faulting in the Coso Geothermal Field, Eastern California Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: Active Faulting in the Coso Geothermal Field, Eastern California Details Activities (1) Areas (1) Regions (0) Abstract: New mapping documents a series of late Quaternary NNE-striking normal faults in the central Coso Range that dip northwest, toward and into the main production area of the Coso geothermal field. The faults exhibit geomorphic features characteristic of Holocene activity, and locally are associated with fumaroles and hydothermal alteration. The active faults sole into or terminate against the brittle-ductile transition zone (BDT) at a depth of about 4 to 5 km. The BDT is arched upward over a volume of crust

79

Module bay with directed flow  

DOE Patents [OSTI]

A module bay requires less cleanroom airflow. A shaped gas inlet passage can allow cleanroom air into the module bay with flow velocity preferentially directed toward contaminant rich portions of a processing module in the module bay. Preferential gas flow direction can more efficiently purge contaminants from appropriate portions of the module bay, allowing a reduced cleanroom air flow rate for contaminant removal. A shelf extending from an air inlet slit in one wall of a module bay can direct air flowing therethrough toward contaminant-rich portions of the module bay, such as a junction between a lid and base of a processing module.

Torczynski, John R. (Albuquerque, NM)

2001-02-27T23:59:59.000Z

80

"ch01" --2009/7/4 --4:33 --page 3 --#3 Thermo-and hydro-mechanical processes along faults during rapid slip  

E-Print Network [OSTI]

"ch01" -- 2009/7/4 -- 4:33 -- page 3 -- #3 Thermo- and hydro-mechanical processes along faults at highly stressed frictional micro-contacts, and (2) Thermal pressurization of fault-zone pore fluid. Both

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

ON CONSISTENCY OF BAYES PROCEDURES  

Science Journals Connector (OSTI)

ON CONSISTENCY OF BAYES PROCEDURES Loraine Schwartz DEPARTMENT OF MATHEMATICS, UNIVERSITY OF BRITISH COLUMBIA...COLUMBIA. | Journal Article ON CONSISTENCY OF BAYES PROCEDURES BY LORAINE SCHWARTZ DEPARTMENT OF MATHEMATICS, UNIVERSITY OF BRITISH COLUMBIA...

Loraine Schwartz

1964-01-01T23:59:59.000Z

82

The Portland Hills Fault: uncovering a hidden fault in Portland, Oregon using high-resolution geophysical methods  

Science Journals Connector (OSTI)

The Portland metropolitan area historically is the most seismically active region in Oregon. At least three potentially active faults are located in the immediate vicinity of downtown Portland, with the Portland Hills Fault (PHF) extending directly beneath downtown Portland. The faults are poorly understood, and the surface geologic record does not provide the information required to assess the seismic hazards associated with them. The limited geologic information stems from a surface topography that has not maintained a cumulative geologic record of faulting, in part, due to rapid erosion and deposition from late Pleistocene catastrophic flood events and a possible strike-slip component of the faults. We integrated multiple high-resolution geophysical techniques, including seismic reflection, ground penetrating radar (GPR), and magnetic methods, with regional geological and geophysical surveys to determine that the Portland Hills Fault is presently active with a zone of deformation that extends at least 400 m. The style of deformation is consistent with at least two major earthquakes in the last 12–15 ka, as confirmed by a sidehill excavation trench. High-resolution geophysical methods provide detailed images of the upper 100 m across the active fault zone. The geophysical images are critical to characterizing the structural style within the zone of deformation, and when integrated with a paleoseismic trench, can accurately record the seismic history of a region with little surface geologic exposure.

Lee M. Liberty; Mark A. Hemphill-Haley; Ian P. Madin

2003-01-01T23:59:59.000Z

83

Permeability characterization of shear zones in the Hickory sandstone member, Riley Formation, Texas  

E-Print Network [OSTI]

. The main objectives of this work are to (1) characterize the geometry and permeability of deformation elements within shear zones; (2) determine permeability anisotropy in shear zones according to fault characteristics and host lithology; and (3) develop... I INTRODUCTION .............................................................................................1 II HICKORY SHEAR ZONES AND DEFORMATION ELEMENTS..............11 2.1 Shear Zones in Hickory Sandstone Member...

Nieto Camargo, Jorge Enrique

2005-02-17T23:59:59.000Z

84

Fault Current Limiters  

Broader source: Energy.gov (indexed) [DOE]

Fault Fault Current Limiters Superconducting & Solid-state Power Equipment Office of Electricity Delivery and Energy Reliability www.oe.energy.gov Office of Electricity Delivery and Energy Reliability, OE-1 U.S. Department of Energy - 1000 Independence Avenue, SW - Washington, DC 20585 Plugging America Into the Future of Power What are FCLs? A fault is an unintentional short circuit, or partial short-circuit, in an electric circuit. A variety of factors such as lightning, downed power lines, or crossed power lines cause faults. During a fault, excessive current-called fault current- flows through the electrical system often resulting in a failure of one section of that system by causing a

85

Acoustic characteristics of bay bottom sediments in Lavaca Bay, TX  

E-Print Network [OSTI]

METHODS An Edgetech X-Star chirp sonar was used to gather subbottom acoustic profile data from Lavaca Bay. The sonar fish was towed on a short line next to the side of the boat, about 0.5 m below the water surface. The data were recorded onto 4 mm... middle Lavaca Bay (just above Chocolate Bay) and Keller bay, which have lines running southwest to northeast (Fig. 1). The subbottom data were plotted and examined on a computer using SonarWeb, a seismic processing program from Chesapeake...

Patch, Mary Catherine

2005-08-29T23:59:59.000Z

86

Fault Location and Incipient Fault Detection in Distribution Cables.  

E-Print Network [OSTI]

??A set of fault location algorithms for underground medium voltage cables, two incipient fault detection schemes for distribution cables and a state estimation method for… (more)

Xu, Zhihan

2011-01-01T23:59:59.000Z

87

Derivation of Delaware Bay tidal parameters from space shuttle photography  

SciTech Connect (OSTI)

The tide-related parameters of the Delaware Bay are derived from space shuttle time-series photographs. The water areas in the bay are measured from interpretation maps of the photographs with a CALCOMP 9100 digitizer and ERDAS Image Processing System. The corresponding tidal levels are calculated using the exposure time annotated on the photographs. From these data, an approximate function relating the water area to the tidal level at a reference point is determined. Based on the function, the water areas of the Delaware Bay at mean high water (MHW) and mean low water (MLW), below 0 m, and for the tidal zone are inferred. With MHW and MLW areas and the mean tidal range, the authors calculate the tidal influx of the Delaware Bay, which is 2.76 x 1O[sup 9] m[sup 3]. Furthermore, the velocity of flood tide at the bay mouth is determined using the tidal flux and an integral of the velocity distribution function at the cross section between Cape Henlopen and Cape May. The result is 132 cm/s, which compares well with the data on tidal current charts.

Zheng, Quanan; Yan, Xiaohai; Klemas, V. (Univ. of Delaware, Newark (United States))

1993-06-01T23:59:59.000Z

88

DAFT: decoupled acyclic fault tolerance  

Science Journals Connector (OSTI)

Higher transistor counts, lower voltage levels, and reduced noise margin increase the susceptibility of multicore processors to transient faults. Redundant hardware modules can detect such errors, but software transient fault detection techniques are ... Keywords: multicore, speculation, transient fault

Yun Zhang; Jae W. Lee; Nick P. Johnson; David I. August

2010-09-01T23:59:59.000Z

89

E-Print Network 3.0 - atera fault central Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

bounded on one... AAPG Bulletin, v. 86, no. 7 (July 2002), pp. 1187-1200 1187 Computing permeability of fault zones... . Durlofsky, and Xian-Huan Wen ABSTRACT The large-scale...

90

Fault Wear by Damage Evolution During Steady-State Slip VLADIMIR LYAKHOVSKY,1  

E-Print Network [OSTI]

, the wear leads to the establishment of gouge and cataclasite zones (Fig. 1b) that range in thickness fromFault Wear by Damage Evolution During Steady-State Slip VLADIMIR LYAKHOVSKY,1 AMIR SAGY,1 YUVAL BONEH,2 and ZE'EV RECHES 3 Abstract--Slip along faults generates wear products such as gouge layers

Lyakhovsky, Vladimir

91

Geological investigation of a lineated massif at the Kane Transform Fault: implications for oceanic core complexes  

Science Journals Connector (OSTI)

...al. 1998; Blackman et al. 1998) and marine multichannel seismic data (White et al...or as striations formed by abrasional wear along a fault surface (Cann et al. 1997...they are not the products of abrasional wear on frictional fault zones, they need not...

1999-01-01T23:59:59.000Z

92

Oil and Gas CDT Predicting fault permeability at depth: incorporating natural  

E-Print Network [OSTI]

Oil and Gas CDT Predicting fault permeability at depth: incorporating natural permeability controls on fluid flow in oil and gas reservoirs. Fault zones are composed of many deformation elements will receive 20 weeks bespoke, residential training of broad relevance to the oil and gas industry: 10 weeks

Henderson, Gideon

93

Solar system fault detection  

DOE Patents [OSTI]

A fault detecting apparatus and method are provided for use with an active solar system. The apparatus provides an indication as to whether one or more predetermined faults have occurred in the solar system. The apparatus includes a plurality of sensors, each sensor being used in determining whether a predetermined condition is present. The outputs of the sensors are combined in a pre-established manner in accordance with the kind of predetermined faults to be detected. Indicators communicate with the outputs generated by combining the sensor outputs to give the user of the solar system and the apparatus an indication as to whether a predetermined fault has occurred. Upon detection and indication of any predetermined fault, the user can take appropriate corrective action so that the overall reliability and efficiency of the active solar system are increased.

Farrington, Robert B. (Wheatridge, CO); Pruett, Jr., James C. (Lakewood, CO)

1986-01-01T23:59:59.000Z

94

Solar system fault detection  

DOE Patents [OSTI]

A fault detecting apparatus and method are provided for use with an active solar system. The apparatus provides an indication as to whether one or more predetermined faults have occurred in the solar system. The apparatus includes a plurality of sensors, each sensor being used in determining whether a predetermined condition is present. The outputs of the sensors are combined in a pre-established manner in accordance with the kind of predetermined faults to be detected. Indicators communicate with the outputs generated by combining the sensor outputs to give the user of the solar system and the apparatus an indication as to whether a predetermined fault has occurred. Upon detection and indication of any predetermined fault, the user can take appropriate corrective action so that the overall reliability and efficiency of the active solar system are increased.

Farrington, R.B.; Pruett, J.C. Jr.

1984-05-14T23:59:59.000Z

95

Heat fluxes in Tampa Bay, Florida.  

E-Print Network [OSTI]

??The Meyers et al. (2007) Tampa Bay Model produces water level and three-dimensional current and salinity fields for Tampa Bay. It is capable of computing… (more)

Sopkin, Kristin L

2008-01-01T23:59:59.000Z

96

Field's Point Wastewater Treatment Facility (Narragansett Bay...  

Open Energy Info (EERE)

Field's Point Wastewater Treatment Facility (Narragansett Bay Commission) Jump to: navigation, search Name Field's Point Wastewater Treatment Facility (Narragansett Bay Commission)...

97

Mission Bay UCSF Campus Boundary  

E-Print Network [OSTI]

Design: reineckandreineck.com, San Francisco UCSF DMM Revised 8/10 6th Street Owens Street Owens Street Haile T. Debas South Gateway UCSF Police Of ce Third Street Garage Plaza Retail/ATM South North Helen Lane Hearst Tower West UCSF Mission Bay/ Gene Friend Way Muni Light Rail Station Mission Bay Housing

Lim, Wendell

98

Climate Zone Number 7 | Open Energy Information  

Open Energy Info (EERE)

Climate Zone Number 7 Climate Zone Number 7 Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard. Climate Zone Number 7 is defined as Very Cold with IP Units 9000 < HDD65ºF ≤ 12600 and SI Units 5000 < HDD18ºC ≤ 7000 . The following places are categorized as class 7 climate zones: Aitkin County, Minnesota Aleutians East Borough, Alaska Aleutians West Census Area, Alaska Anchorage Borough, Alaska Aroostook County, Maine Ashland County, Wisconsin Baraga County, Michigan Barnes County, North Dakota Bayfield County, Wisconsin Becker County, Minnesota Beltrami County, Minnesota Benson County, North Dakota Bottineau County, North Dakota Bristol Bay Borough, Alaska Burke County, North Dakota Burnett County, Wisconsin Carlton County, Minnesota Cass County, Minnesota

99

Modeling of coulpled deformation and permeability evolution during fault reactivation induced by deep underground injection of CO2  

SciTech Connect (OSTI)

The interaction between mechanical deformation and fluid flow in fault zones gives rise to a host of coupled hydromechanical processes fundamental to fault instability, induced seismicity, and associated fluid migration. In this paper, we discuss these coupled processes in general and describe three modeling approaches that have been considered to analyze fluid flow and stress coupling in fault-instability processes. First, fault hydromechanical models were tested to investigate fault behavior using different mechanical modeling approaches, including slip interface and finite-thickness elements with isotropic or anisotropic elasto-plastic constitutive models. The results of this investigation showed that fault hydromechanical behavior can be appropriately represented with the least complex alternative, using a finite-thickness element and isotropic plasticity. We utilized this pragmatic approach coupled with a strain-permeability model to study hydromechanical effects on fault instability during deep underground injection of CO{sub 2}. We demonstrated how such a modeling approach can be applied to determine the likelihood of fault reactivation and to estimate the associated loss of CO{sub 2} from the injection zone. It is shown that shear-enhanced permeability initiated where the fault intersects the injection zone plays an important role in propagating fault instability and permeability enhancement through the overlying caprock.

Cappa, F.; Rutqvist, J.

2010-06-01T23:59:59.000Z

100

Fault Block Kinematics at a Releasing Stepover of the Eastern California  

Open Energy Info (EERE)

Fault Block Kinematics at a Releasing Stepover of the Eastern California Fault Block Kinematics at a Releasing Stepover of the Eastern California Shear Zone: Partitioning of Rotation Style in and Around the Coso Geothermal Area and Nascent Metamorphic Core Complex Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Fault Block Kinematics at a Releasing Stepover of the Eastern California Shear Zone: Partitioning of Rotation Style in and Around the Coso Geothermal Area and Nascent Metamorphic Core Complex Abstract Pliocene lavas and sediments of Wild Horse Mesa in the Coso Range, CA exhibit clockwise vertical-axis rotation of fault-bounded blocks. This indicates localization of one strand of the Eastern California shear zone/Walker Lane Belt within a large-scale, transtensional, dextral, releasing stepover. We measured rotations paleomagnetically relative to two

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Student Zone  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Student Zone Student Zone Homework Helpers All About Atoms - Learn about the parts of the atom! Virginia State Standards of Learning Practice Tests - Practice taking the SOL tests! Subjects currently include algebra, math, science and technology. Table of Elements - Basic physical and historical information about the elements! [Printable Version] Questions and Answers - Have a question? Need an answer? Check here first! Glossary of Science Terms - Definitions of some of the terms used on this site. Jefferson Lab Virtual Tour - How do scientists explore inside atoms? Video Resources Frostbite Theater - Short science experiments using liquid nitrogen, static electricity and more! Physics Out Loud - Jefferson Lab scientists and other experts explain some of the common words and terms used in nuclear physics research.

102

Field Mapping At Central Nevada Seismic Zone Region (Shevenell, Et Al.,  

Open Energy Info (EERE)

Shevenell, Et Al., Shevenell, Et Al., 2008) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Field Mapping At Central Nevada Seismic Zone Region (Shevenell, Et Al., 2008) Exploration Activity Details Location Central Nevada Seismic Zone Geothermal Region Exploration Technique Field Mapping Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes On a more local scale, Faulds et al. (2003, 2005a, 2005b, 2006) have conducted structural analysis and detailed geologic mapping at a number of sites throughout Nevada and have found that productive geothermal systems typically occur in one of several structural settings, including step-overs in normal fault zones, near the ends of major normal faults where the faults break into multiple splays, in belts of overlapping faults, at fault

103

Evaluation of the location and recency of faulting near prospective surface facilities in Midway Valley, Nye County, Nevada  

SciTech Connect (OSTI)

Evaluation of surface faulting that may pose a hazard to prospective surface facilities is an important element of the tectonic studies for the potential Yucca Mountain high-level radioactive waste repository in southwestern Nevada. For this purpose, a program of detailed geologic mapping and trenching was done to obtain surface and near-surface geologic data that are essential for determining the location and recency of faults at a prospective surface-facilities site located east of Exile Hill in Midway Valley, near the eastern base of Yucca Mountain. The dominant tectonic features in the Midway Valley area are the north- to northeast-trending, west-dipping normal faults that bound the Midway Valley structural block-the Bow Ridge fault on the west side of Exile Hill and the Paint-brush Canyon fault on the east side of the valley. Trenching of Quaternary sediments has exposed evidence of displacements, which demonstrate that these block-bounding faults repeatedly ruptured the surface during the middle to late Quaternary. Geologic mapping, subsurface borehole and geophysical data, and the results of trenching activities indicate the presence of north- to northeast-trending faults and northwest-trending faults in Tertiary volcanic rocks beneath alluvial and colluvial sediments near the prospective surface-facilities site. North to northeast-trending faults include the Exile Hill fault along the eastern base of Exile Hill and faults to the east beneath the surficial deposits of Midway Valley. These faults have no geomorphic expression, but two north- to northeast-trending zones of fractures exposed in excavated profiles of middle to late Pleistocene deposits at the prospective surface-facilities site appear to be associated with these faults. Northwest-trending faults include the West Portal and East Portal faults, but no disruption of Quaternary deposits by these faults is evident. The western zone of fractures is associated with the Exile Hill fault. The eastern zone of fractures is within Quaternary alluvial sediments, but no bedrock was encountered in trenches and soil pits in this part of the prospective surface facilities site; thus, the direct association of this zone with one or more bedrock faults is uncertain. No displacement of lithologic contacts and soil horizons could be detected in the fractured Quaternary deposits. The results of these investigations imply the absence of any appreciable late Quaternary faulting activity at the prospective surface-facilities site.

Swan, F.H.; Wesling, J.R.; Angell, M.M.; Thomas, A.P.; Whitney, J.W.; Gibson, J.D.

2002-01-17T23:59:59.000Z

104

Vermilion Bay | Open Energy Information  

Open Energy Info (EERE)

Vermilion Bay Vermilion Bay Jump to: navigation, search Name Vermilion Bay Facility Vermilion Bay Sector Wind energy Facility Type Offshore Wind Facility Status Proposed Owner Coastal Point Energy LLC Developer Coastal Point Energy LLC Location Gulf of Mexico LA Coordinates 29.741°, -92.057° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":29.741,"lon":-92.057,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

105

Tidal Computations for Morecambe Bay  

Science Journals Connector (OSTI)

......Feasibility study of water conservation in Morecambe Bay, Report...very small amounts of water left behind as the tide recedes and since these pools are in no way connected...Feasibility study of water conservation in driven ocean circulations......

R. A. Flather; N. S. Heaps

1975-08-01T23:59:59.000Z

106

Offshore wind resources from satellite SAR Charlotte Bay Hasager, Merete Bruun Christiansen, Morten Nielsen,  

E-Print Network [OSTI]

Offshore wind resources from satellite SAR Charlotte Bay Hasager, Merete Bruun Christiansen, Morten ocean wind maps were described. For offshore wind resource estimation based on satellite observations and the near-coastal zone (up to 40 km offshore) is not mapped. In contrast, Envisat ASAR wind maps can

107

Quaternary faults of the central Rocky Mountains, Colorado: A new seismotectonic evaluation  

SciTech Connect (OSTI)

Quaternary faults in the central Rocky Mountain of CO exhibit normal displacement, are generally parallel to the strike of pre-existing Larmide structures, and typically occur in the hanging walls of Laramide thrust faults. These observations are consistent with models in which Mesozoic thrust faults are being reactivated as normal faults in the contemporary extensional tectonic setting. To assess the seismogenic potential of these faults, the authors evaluated the recency of fault movement and style of deformation via aerial reconnaissance, interpretation of aerial photography and field mapping of selected sites. The 82-km-long Red Rocks-Climarron fault zone shows evidence of late Quaternary displacement and may be capable of producing an M[>=]6.75 earthquake based on its total fault length and inferred fault width. Earthquake hypocenters indicate that the thickness of the seismogence crust in CO is similar to much of the western US (ca. 15 km). In additional to tectonic deformation, numerous faults and lineaments have been identified in the Paradox Basin and along the southern Grand Hogback monocline that are active due to diapiric movement of halite. In particular, active deformation along the Grand Hogback is limited to portions of the structure underlain by a 3-km-deep Pennsylvania halite basin. Because Quaternary deformation along and near these large Laramide structures is due to the movement of halite rather than deep-seated tectonism, the maximum size of a potential earthquake is limited by the down-dip width and lateral extent of fault planes within brittle rocks overlying the halite. The authors infer that the maximum depth of brittle faulting due to diapiric halite flow is 6 km, and the earthquakes larger than M 5 are unlikely to occur on faults associated with the Grand Hogback and salt anticlines of the Paradox Basin. The 1984 Carbondale earthquake swarm (M[<=]3.2) may have been the result of such faulting.

Unruh, J.R.; Noller, J.S.; Lettis, W.R. (William Lettis and Association, Inc., Oakland, CA (United States)); Wong, I.G.; Sawyer, T.L.; Bott, J.D.J. (Woodward-Clyde Federal Services, Oakland, CA (United States))

1993-04-01T23:59:59.000Z

108

Computer hardware fault administration  

DOE Patents [OSTI]

Computer hardware fault administration carried out in a parallel computer, where the parallel computer includes a plurality of compute nodes. The compute nodes are coupled for data communications by at least two independent data communications networks, where each data communications network includes data communications links connected to the compute nodes. Typical embodiments carry out hardware fault administration by identifying a location of a defective link in the first data communications network of the parallel computer and routing communications data around the defective link through the second data communications network of the parallel computer.

Archer, Charles J. (Rochester, MN); Megerian, Mark G. (Rochester, MN); Ratterman, Joseph D. (Rochester, MN); Smith, Brian E. (Rochester, MN)

2010-09-14T23:59:59.000Z

109

Optimal fault location  

E-Print Network [OSTI]

for the pre-selected time out to pass and initiate reclosing again. If after selected number of attempts of reclosing, fault is still present, breaker lockout is taking place. There will be no more attempts to reclose automatically the breaker again....2: Trip and reclose sequences on a single breaker In the case of breaker lockout the assumption taken by the operators is that fault is permanent. Special order is issued to the maintenance for the breaker to be closed back in 4 again once...

Knezev, Maja

2009-05-15T23:59:59.000Z

110

Optimal fault location  

E-Print Network [OSTI]

for the pre-selected time out to pass and initiate reclosing again. If after selected number of attempts of reclosing, fault is still present, breaker lockout is taking place. There will be no more attempts to reclose automatically the breaker again....2: Trip and reclose sequences on a single breaker In the case of breaker lockout the assumption taken by the operators is that fault is permanent. Special order is issued to the maintenance for the breaker to be closed back in 4 again once...

Knezev, Maja

2008-10-10T23:59:59.000Z

111

Development of Hydrologic Characterization Technology of Fault Zones  

E-Print Network [OSTI]

heterogeneity on the fluid flow and heat transfer regime,heterogeneity on the fluid flow and heat transfer regime,for Simulating Fluid Flow and Heat Transfer in Unsaturated

Karasaki, Kenzi

2009-01-01T23:59:59.000Z

112

Development of Hydrologic Characterization Technology of Fault Zones  

E-Print Network [OSTI]

Young University, 2005. Evans, James P. , Craig B. Forster2005. Hammond, K. Jill and James P. Evans, Geochemistry,Caine, Jonathan Saul, James P. Evans, and Craig B. Forster,

Karasaki, Kenzi

2009-01-01T23:59:59.000Z

113

Row fault detection system  

DOE Patents [OSTI]

An apparatus, program product and method check for nodal faults in a row of nodes by causing each node in the row to concurrently communicate with its adjacent neighbor nodes in the row. The communications are analyzed to determine a presence of a faulty node or connection.

Archer, Charles Jens (Rochester, MN); Pinnow, Kurt Walter (Rochester, MN); Ratterman, Joseph D. (Rochester, MN); Smith, Brian Edward (Rochester, MN)

2012-02-07T23:59:59.000Z

114

Sonar imaging of bay bottom sediments and anthropogenic impacts in Galveston Bay, Texas  

E-Print Network [OSTI]

Knowledge of surface sediment distribution in Galveston Bay is important because it allows us to better understand how the bay works and how human activities impact the bay and its ecosystems. In this project, six areas of bay bottom were surveyed...

Maddox, Donald Shea

2007-04-25T23:59:59.000Z

115

A High shear stress segment along the San Andreas Fault: Inferences based on near-field stress direction and stress magnitude observations in the Carrizo Plain Area  

SciTech Connect (OSTI)

Nearly 200 new in-situ determinations of stress directions and stress magnitudes near the Carrizo plain segment of the San Andreas fault indicate a marked change in stress state occurring within 20 km of this principal transform plate boundary. A natural consequence of this stress transition is that if the observed near-field ``fault-oblique`` stress directions are representative of the fault stress state, the Mohr-Coulomb shear stresses resolved on San Andreas sub-parallel planes are substantially greater than previously inferred based on fault-normal compression. Although the directional stress data and near-hydrostatic pore pressures, which exist within 15 km of the fault, support a high shear stress environment near the fault, appealing to elevated pore pressures in the fault zone (Byerlee-Rice Model) merely enhances the likelihood of shear failure. These near-field stress observations raise important questions regarding what previous stress observations have actually been measuring. The ``fault-normal`` stress direction measured out to 70 km from the fault can be interpreted as representing a comparable depth average shear strength of the principal plate boundary. Stress measurements closer to the fault reflect a shallower depth-average representation of the fault zone shear strength. If this is true, only stress observations at fault distances comparable to the seismogenic depth will be representative of the fault zone shear strength. This is consistent with results from dislocation monitoring where there is pronounced shear stress accumulation out to 20 km of the fault as a result of aseismic slip within the lower crust loading the upper locked section. Beyond about 20 km, the shear stress resolved on San Andreas fault-parallel planes becomes negligible. 65 refs., 15 figs.

Castillo, D. A., [Department of Geology and Geophysics, University of Adelaide (Australia); Younker, L.W. [Lawrence Livermore National Lab., CA (United States)

1997-01-30T23:59:59.000Z

116

ID3, SEQUENTIAL BAYES, NAIVE BAYES AND BAYESIAN NEURAL NETWORKS  

E-Print Network [OSTI]

to ID3. ID3 learning algorithm (Quinlan 1979) and its successors ACLS (Paterson & Niblett 1982), C4#cient in many learning tasks. It is shown how Sequential Bayes can be transformed into ID3 by replacing of network's execution (Kononenko 1989) enables the us­ age of a neural network as an expert system shell

Kononenko, Igor

117

Modeling of the surface static displacements and fault plane slip for the 1979 Imperial Valley earthquake  

SciTech Connect (OSTI)

Three-dimensional finite element modeling techniques are used to synthesize geodetic and seismological results for 1979 Imperial Valley earthquake. The strategy pursued consists of two principal steps. In the first step, the seismologically-derived coseismic fault slip is taken as a function of position in the fault plane and is applied directly to the three-dimensional dislocation model. In the second step, a physical model of stresses and constitutive parameters is perturbed so as to reproduce the observed fault slip. Hence, the principal features of the coseismic slip pattern are explained by a stress-driven fault model in which: (1) a spatially unresolved asperity is found equivalent to a stress drop of 18 MPa averaged over an area of 15 sq km, and (2) driving stress is essentially absent on the fault segment overlapping the 1940 earthquake rupture zone. 24 references.

Slade, M.A.; Lyzenga, G.A.; Raefsky, A.

1984-12-01T23:59:59.000Z

118

Structural styles of the Wilcox and Frio growth-fault trends in Texas: Constraints on geopressured reservoirs  

SciTech Connect (OSTI)

The wide variability in structural styles within the growth-faulted, geopressured trends of the Texas Gulf Coast is illustrated by detailed structural maps of selected areas of the Wilcox and Frio growth-fault trends and quantified by statistical analysis of fault compartment geometries. Structural variability is a key determinant of the size of geopressured aquifers in the deep subsurface. Two major structural styles exist in the Wilcox trend. (1) In southeast and Central Texas, the trend consists of continuous, closely spaced faults that have little associated rollover despite moderate expansion of section; the fault plane flattens little with depth. (2) By contrast, in South Texas a narrow band of growth faults having high expansion and moderate rollover lies above and downdip of a ridge of deformed, overpressured shale but updip of a deep basin formed by withdrawal of overpressured shale. Frio fault systems generally display greater rollover and wider spacing than do Wilcox fault systems; however, the Frio trend displays distinctive features in each study area. Most of the Frio growth faults, however, have a similar geometry, showing substantial rollover, expansion of section, and a moderate flattening of the fault zone with depth, possibly related to a deep decollement surface. The local variability in style is related to the magnitude of Frio sedimentation and progradation and to the presence of thick salt or shale. Finding and developing a large geopressured aquifer require recognition of a favorable combination of sand-body geometry, reservoir quality, and fault compartment size and shape.

Ewing, T.E.

1986-01-01T23:59:59.000Z

119

CAROLINA BAYS AND THEIR ORIGIN  

Science Journals Connector (OSTI)

...peat, very fine, soft and sticky when wet and dries to a hard, brittle mass. It...finer particles formed by the constant milling of the sand by the spring are carried away...1935; MacCarthy, 1937) and written corn- respect to bays may not be found tenable...

120

PACIFIC OCEAN SOUTH BAY HARBOR  

E-Print Network [OSTI]

PACIFIC OCEAN LONG BEACH SOUTH BAY HARBOR GATEWAY NORWALK PASADENA EAST LA DOWNTOWN LOS ANGELES W illow P Pacific CoastHw y Anaheim 5th St 1stSt P©$ P©$ Transit Mall P©$ Pacific Long Beach P Lakew

Weinreb, Sander

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Daya Bay Reactor Neutrino Project at NERSC  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Daya Bay Reactor Neutrino Daya Bay Reactor Neutrino Experiment Daya Bay Reactor Neutrino Experiment Daya Bay is an international neutrino-oscillation experiment designed to determine the last unknown neutrino mixing angle θ13 using anti-neutrinos produced by the Daya Bay and Ling Ao Nuclear Power Plant reactors. The experiment is being built by blasting three kilometers of tunnel through the granite rock under the mountains where the power plants are located. Data collection is now scheduled to start in in 2011. On the PDSF cluster at NERSC, Daya Bay performs simulations of the detectors, reactors, and surrounding mountains to help design and anticipate detector properties and behavior. Once real data are available, Daya Bay will be using NERSC to analyze data and NERSC HPSS will be the central U.S. repository for all raw

122

Complex Faulting in the Yuha Desert: Implications for Fault Interaction  

E-Print Network [OSTI]

Dibblee. Geology of the Imperial Valley region, California,and tectonics of the Imperial Valley region, California. Innent faults surrounding the Imperial Valley region, southern

Kroll, Kayla Ann

2012-01-01T23:59:59.000Z

123

Structural character of the northern segment of the Paintbrush Canyon fault, Yucca Mountain, Nevada  

SciTech Connect (OSTI)

Detailed mapping of exposed features along the northern part of the Paintbrush Canyon fault was initiated to aid in construction of the computer-assisted three-dimensional lithostratigraphic model of Yucca Mountain, to contribute to kinematic reconstruction of the tectonic history of the Paintbrush Canyon fault, and to assist in the interpretation of geophysical data from Midway Valley. Yucca Mountain is segmented into relatively intact blocks of east-dipping Miocene volcanic strata, bounded by north-striking, west-dipping high-angle normal faults. The Paintbrush Canyon fault, representing the easternmost block-bounding normal fault, separates Fran Ridge from Midway Valley and continues northward across Yucca Wash to at least the southern margin of the Timber Mountain Caldera complex. South of Yucca Wash, the Paintbrush Canyon Fault is largely concealed beneath thick Quaternary deposits. Bedrock exposures to the north reveal a complex fault, zone, displaying local north- and west-trending grabens, and rhombic pull-apart features. The fault scarp, discontinuously exposed along a mapped length of 8 km north of Yucca Wash, dips westward by 41{degrees} to 74{degrees}. Maximum vertical offset of the Rhyolite of Comb Peak along the fault measures about 210 m in Paintbrush Canyon and, on the basis of drill hole information, vertical offset of the Topopoah Spring Tuff is about 360 m near the northern part of Fran Ridge. Observed displacement along the fault in Paintbrush Canyon is down to the west with a component of left-lateral oblique slip. Unlike previously proposed tectonic models, strata adjacent to the fault dip to the east. Quaternary deposits do not appear displaced along the fault scarp north of Yucca Wash, but are displaced in trenches south of Yucca Wash.

Dickerson, R.P. [Science Applications International Corp., Golden, CO (United States); Spengler, R.W. [Geological Survey, Denver, CO (United States)

1994-12-31T23:59:59.000Z

124

Fault Mapping | Open Energy Information  

Open Energy Info (EERE)

form form View source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit with form History Facebook icon Twitter icon » Fault Mapping Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Fault Mapping Details Activities (2) Areas (2) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Field Techniques Exploration Sub Group: Data Collection and Mapping Parent Exploration Technique: Data Collection and Mapping Information Provided by Technique Lithology: Stratigraphic/Structural: Locates active faults in the area of interest Hydrological: Can reveal whether faults are circulating hydrothermal fluids Thermal: Dictionary.png

125

2 Spatial variations in slip rate along the Death Valley-Fish Lake Valley 3 fault system determined from LiDAR topographic data and  

E-Print Network [OSTI]

deformation is accommodated on 22 structures east of Fish Lake Valley, or that rates of seismic 23 strain2 Spatial variations in slip rate along the Death Valley-Fish Lake Valley 3 fault system determined; accepted 11 July 2007; published XX Month 2007. 9 [1] The Death Valley-Fish Lake Valley fault zone (DV- 10

Black, Robert X.

126

Spatial variations in slip rate along the Death Valley-Fish Lake Valley fault system determined from LiDAR topographic data and  

E-Print Network [OSTI]

east of Fish Lake Valley, or that rates of seismic strain accumulation and release have not remainedSpatial variations in slip rate along the Death Valley-Fish Lake Valley fault system determined; accepted 11 July 2007; published 19 September 2007. [1] The Death Valley-Fish Lake Valley fault zone (DV

Frankel, Kurt L.

127

Effect of faulting on ground-water movement in the Death Valley region, Nevada and California  

SciTech Connect (OSTI)

This study characterizes the hydrogeologic system of the Death Valley region, an area covering approximately 100,000 square kilometers. The study also characterizes the effects of faults on ground-water movement in the Death Valley region by synthesizing crustal stress, fracture mechanics,a nd structural geologic data. The geologic conditions are typical of the Basin and Range Province; a variety of sedimentary and igneous intrusive and extrusive rocks have been subjected to both compressional and extensional deformation. Faulting and associated fracturing is pervasive and greatly affects ground-water flow patterns. Faults may become preferred conduits or barriers to flow depending on whether they are in relative tension, compression, or shear and other factors such as the degree of dislocations of geologic units caused by faulting, the rock types involved, the fault zone materials, and the depth below the surface. The current crustal stress field was combined with fault orientations to predict potential effects of faults on the regional ground-water flow regime. Numerous examples of fault-controlled ground-water flow exist within the study area. Hydrologic data provided an independent method for checking some of the assumptions concerning preferential flow paths. 97 refs., 20 figs., 5 tabs.

Faunt, C.C.

1997-12-31T23:59:59.000Z

128

Berkeley Lab / Richmond Bay Campus  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Second Campus Second Campus Long Range Development Plan Environmental Docs Department of Energy NEPA Environmental Documents Frequently Asked Questions (FAQ) Timeline Community Meetings Selection Process Contacts The Science The University of California, Berkeley and the University of California at the Lawrence Berkeley National Laboratory propose to establish a new research campus - the Richmond Bay Campus - in Richmond, California. The purpose of the proposed campus is to build upon the University of California's record of accomplishment in providing long-term societal benefits through discovery and the advancement of knowledge. UC Berkeley and Lawrence Berkeley National Laboratory's goals for the Richmond Bay Campus are: Advance LBNL and UC Berkeley's tradition of world class science by

129

The character and reactivation history of the southern extension of the seismically active Clarendon–Linden Fault System, western New York State  

Science Journals Connector (OSTI)

Integration of 11 types of data sets enabled us to determine the location, character and fault history of the southern extension of the Clarendon–Linden Fault System (CLF) in southwestern New York State. The data sets utilized include detailed stratigraphic and fracture measurements at more than 1000 sites, soil gas anomalies, seismic reflection profiles, well logs and lineaments on air photos, topographic maps, Landsat and SLAR images. The seismically active CLF consists of as many as 10 parallel, segmented faults across the fault system. The fault segments are truncated by NW-striking cross-strike discontinuities (CSDs). The faults of the CLF and intersecting \\{CSDs\\} form fault blocks that have semi-independent subsidence and uplift histories. East-dipping reflectors in the Precambrian basement indicate the southward continuation of thrusts of the intra-Grenvillian Elzevir–Frontenac Boundary Zone. These thrusts were reactivated during Iapetan rifting as normal (listric) growth faults. In Ordovician Black River to Trenton time, the southern CLF segments experienced a second phase of growth fault activity, with faults displaying a cumulative stratigraphic throw of as much as ?170 m. Thrusting on the same east-dipping Precambrian reflectors typified the CLF in Taconic (post-Trenton) times. Detailed comparisons among the fault segments show that the fault activity in Silurian and Devonian times generally alternated between the western and central main faults. In Late Devonian time, the fault motion reversed from down-on-the-east to down-on-the-west about the time the Appalachian Basin axis passed across the CLF in its westward migration. The deep Precambrian faults of the CLF were thus reactivated as the Appalachian Basin developed in Acadian times. Finally, the CLF thrust fault imaged on seismic line CLF-1 offsets all bedrock (Devonian) units; thus, significant motion occurred along this fault during Late Acadian, or more likely, Alleghanian time.

Robert D. Jacobi; John Fountain

2002-01-01T23:59:59.000Z

130

Definition: Enhanced Fault Protection | Open Energy Information  

Open Energy Info (EERE)

Enhanced Fault Protection Enhanced Fault Protection Enhanced fault protection requires higher precision and greater discrimination of fault location and type with coordinated measurement among multiple devices. For distribution applications, these systems will detect and isolate faults without full-power re-closing, reducing the frequency of through-fault currents. Using high resolution sensors and fault signatures, these systems can better detect high impedance faults. For transmission applications, these systems will employ high speed communications between multiple elements (e.g., stations) to protect entire regions, rather than just single elements. They will also use the latest digital techniques to advance beyond conventional impedance relaying of transmission lines.[1] Related Terms

131

Intelligent fault diagnosis of power transmission line; -.  

E-Print Network [OSTI]

??This dissertation presents the application of recent intelligent newlinetechniques for fault diagnosis in electrical power transmission line Fault newlinesection identification classification and location are the… (more)

Malathi, V

2014-01-01T23:59:59.000Z

132

Transition-fault test generation  

E-Print Network [OSTI]

large to store in the memory of the tester. The proposed methods of test generation utilize stuck-at-fault tests to create transition-fault test sets of a smaller size. Greedy algorithms are used in the generation of both the stuck...

Cobb, Bradley Douglas

2013-02-22T23:59:59.000Z

133

Earthquake Fault Studies in Japan  

Science Journals Connector (OSTI)

17 May 1973 research-article Earthquake Fault Studies in Japan K. Kasahara The paper reviews the current status of earthquake fault studies in Japan, taking the work on the off-Honshu tectonics as an example. Within the Japanese tectonic...

1973-01-01T23:59:59.000Z

134

Sediment resuspension in Saginaw Bay  

Science Journals Connector (OSTI)

Abstract An integrated hydrodynamic and sediment transport model was applied to Saginaw Bay for the ice-free portions of 2009 and 2010. Observations of surface waves and suspended sediment concentration made during the spring of both years were used to constrain the model and to validate the model output. The results show that sediment resuspension in both the inner and outer bay is due almost entirely to surface wave action, and that the bulk of the resuspension events occur during the fall of each year. Although the model accurately predicted the occurrence of resuspension events, it did not always accurately simulate the amount of material resuspended. Because resuspension mixes bottom sediment into the water column and makes it and associated nutrients available to the biota, the effects of sediment resuspension need to be accounted for in any water quality model of the bay. Better specification of both the surface waves and the initial specification of the bottom sediment would probably improve the performance of the model.

Nathan Hawley; Todd Redder; Raisa Beletsky; Edward Verhamme; Dmitry Beletsky; Joseph V. DePinto

2014-01-01T23:59:59.000Z

135

Observer-based fault detection for nuclear reactors  

E-Print Network [OSTI]

This is a study of fault detection for nuclear reactor systems. Basic concepts are derived from fundamental theories on system observers. Different types of fault- actuator fault, sensor fault, and system dynamics fault ...

Li, Qing, 1972-

2001-01-01T23:59:59.000Z

136

MODELING THE FATE AND TRANSPORT OF ATRAZINE IN THE UPPER CHESAPEAKE BAY  

E-Print Network [OSTI]

for agrochemicals in the Upper Chesapeake Bay. Keywords: Chesapeake Bay, hydrodynamic model, atrazine, photolysis

Frei, Allan

137

Clean Cities: Tampa Bay Clean Cities coalition  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

vehicle fleets, fuel providers, community leaders, and other stakeholders to reduce petroleum use in transportation. Tampa Bay Clean Cities coalition Contact Information Stephen...

138

Humboldt Bay Initiative: 2001 update and accomplishments  

E-Print Network [OSTI]

from the Humboldt Bay Sea Level Rise Synthesis and Communityis essential to all sea level rise forecasting, estuarineDiego ? ? Visualizing sea-level rise and potential impacts

Schlosser, Susan; Price-Hall, Rebecca

2011-01-01T23:59:59.000Z

139

Exploring Hydrodynamic Modeling of Texas Bays With focus on Corpus Christi Bay & Lavaca Bay  

E-Print Network [OSTI]

evaporation data or data from which evaporation may be estimated are required. In order to estimate evaporation, ELCOM requires solar radiation data, water/air temperature data, wind speed data, cloud cover, and other geographically significant factors..., and this inflow has been demonstrated to be significant from the TxBLEND modeling. The inflow will be estimated from the USGS gauged riverflow on the Nueces river, minus estimated evaporation losses. Environmental Forcing Group #3 – Exchange between Oso Bay...

Furnans, Jordan

2004-01-01T23:59:59.000Z

140

Tampa Bay Area Ethanol Consortium | Open Energy Information  

Open Energy Info (EERE)

Tampa Bay Area Ethanol Consortium Jump to: navigation, search Name: Tampa Bay Area Ethanol Consortium Place: Tampa, Florida Sector: Biomass Product: Consortium researching ethanol...

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

San Francisco Bay Conservation and Development Commission | Open...  

Open Energy Info (EERE)

and Development Commission Jump to: navigation, search Logo: San Francisco Bay Conservation and Development Commission Name: San Francisco Bay Conservation and Development...

142

Arc fault detection system  

DOE Patents [OSTI]

An arc fault detection system for use on ungrounded or high-resistance-grounded power distribution systems is provided which can be retrofitted outside electrical switchboard circuits having limited space constraints. The system includes a differential current relay that senses a current differential between current flowing from secondary windings located in a current transformer coupled to a power supply side of a switchboard, and a total current induced in secondary windings coupled to a load side of the switchboard. When such a current differential is experienced, a current travels through a operating coil of the differential current relay, which in turn opens an upstream circuit breaker located between the switchboard and a power supply to remove the supply of power to the switchboard.

Jha, Kamal N. (Bethel Park, PA)

1999-01-01T23:59:59.000Z

143

Field Mapping At Walker-Lane Transitional Zone Region (Shevenell, Et Al.,  

Open Energy Info (EERE)

Walker-Lane Transitional Zone Region (Shevenell, Et Al., Walker-Lane Transitional Zone Region (Shevenell, Et Al., 2008) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Field Mapping At Walker-Lane Transitional Zone Region (Shevenell, Et Al., 2008) Exploration Activity Details Location Walker-Lane Transition Zone Geothermal Region Exploration Technique Field Mapping Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes On a more local scale, Faulds et al. (2003, 2005a, 2005b, 2006) have conducted structural analysis and detailed geologic mapping at a number of sites throughout Nevada and have found that productive geothermal systems typically occur in one of several structural settings, including step-overs in normal fault zones, near the ends of major normal faults where the

144

Interseismic fault strengthening and earthquake-slip instability: Friction or cohesion?  

Science Journals Connector (OSTI)

...instability of an earthquake and its abrupt energy release depend primarily on the intensity...White Sands National Monument, New Mexico, United States) with a mean particle size...during long interseismic periods would reform a fault zone into intact rock. The slip...

145

GEOLOGY, December 2011 1131 Active faults in the upper crust can either slide steadily by  

E-Print Network [OSTI]

accommodate the aseismic deformation of the San Andreas fault. The SAFOD borehole, drilled to 3 km depth by aseismic creep, or abruptly causing earthquakes. Creep relaxes the stress and prevents large earthquakes). Borehole casing deformation revealed two low-seismic-velocity, actively creeping, zones of foliated rocks

146

Other Fresnel Zone Antennas  

Science Journals Connector (OSTI)

In the preceding chapters, theoretical investigations and experiments on a number of Fresnel zone antennas are presented. This chapter is intended to introduce a wider range of Fresnel zone antennas. Section 7...

Y. Jay Guo; Stephen K. Barton

2002-01-01T23:59:59.000Z

147

Enterprise Zone Program (Illinois)  

Broader source: Energy.gov [DOE]

The Enterprise Zone Program provides eligible businesses that relocate or expand to a designated zone with tax incentives such as: 1) an investment tax credit; 2) a job tax credit for each job...

148

Alternative Energy Zone (Ohio)  

Broader source: Energy.gov [DOE]

Ohio's Alternative Energy Zones are made possible through Ohio's Senate Bill 232, which reduced taxes on alternative energy projects. The Alternative Energy Zones are designated on a county-by...

149

Hot Pot Detail - Evidence of Quaternary Faulting  

SciTech Connect (OSTI)

Compilation of published data, field observations and photo interpretation relevant to Quaternary faulting at Hot Pot.

Lane, Michael

2013-06-27T23:59:59.000Z

150

Hot Pot Detail - Evidence of Quaternary Faulting  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Compilation of published data, field observations and photo interpretation relevant to Quaternary faulting at Hot Pot.

Lane, Michael

151

Zoning and Permitting Resources  

Broader source: Energy.gov [DOE]

Zoning and permitting is commonly controlled by local governments and may be applicable to both residential and commercial properties.

152

Bay area regional water recycling program  

SciTech Connect (OSTI)

The Bay Area Regional Water Recycling Project is a partnership of 19 water and wastewater agencies working to maximize San Francisco Bay Area water recycling. Benefits of the partnership are described, and the methodologies and analysis tools to implement the regional approach are identified.

Ritchie, S.; Bailey, M.; Raines, R.

1998-07-01T23:59:59.000Z

153

Using the eBay API  

Science Journals Connector (OSTI)

In chapters 3, 4, 5, and 6...of this book, you learned how to access the eBay service using the high-level eBay SDK, which provides an abstraction that lets you treat the remotely hosted resources of...

Ray Rischpater

2004-01-01T23:59:59.000Z

154

Low Oxygen Environments in Chesapeake Bay  

E-Print Network [OSTI]

Low Oxygen Environments in Chesapeake Bay Jeremy Testa Chesapeake Biological Laboratory University of Maryland Center for Environmental Science Why we care about low oxygen? What causes low oxygen? Where and When does Chesapeake Bay lose oxygen? #12;#12;Hypoxia and Chesapeake Animals Low dissolved oxygen

Boynton, Walter R.

155

Earth-Fault Relay Equipment  

Science Journals Connector (OSTI)

... proving the reliability of the equipment. By Observing the operation of the relays at each substation with faults at selected points, the complete scheme can be put into operation with ...

1944-04-15T23:59:59.000Z

156

Verification of inferred faults by resistivity analysis. Technical progress report, July 17-October 31, 1981  

SciTech Connect (OSTI)

The major purpose of this effort is to detect new faults which may indicate fracture systems with potential for gas production from the black shales. The method is to gather surface geophysical data, principally resistivity, to test Landsat lineaments as faults. A second purpose is to develop an economical method of confirming remotely sensed lineaments as faults or fractures which can be applied in this region and perhaps be extended to the eastern part of the United States. To attain the goal of this work, the planned approach was to use high-powered (3KW) resistivity measurements in a dipole-dipole configuration to penetrate deeply - a rather expensive procedure. Toward this end it was decided to make a preliminary investigation using a scintillation counter in addition to a low-current resistivity measuring instrument. The scintillation counter gave more definite indication of known faults than did the resistivity measurements. The South Graham, North Graham, and the fault at Highways 403-269, Kentucky were all indicated on one traverse by scintillation measurements, but only the North Graham fault was indicated by resistivity, and the resistivities profile was not conclusive. The reason for the inconclusive resistivity result may have been the fact that the fault zones in this region are often thin, sometimes a matter of a few inches.

Jackson, P.L.

1981-01-01T23:59:59.000Z

157

Thoughts Regarding the Dimensions of Faults at Rainier and Aqueduct Mesas, Nye County, Nevada, Based on Surface and Underground Mapping  

SciTech Connect (OSTI)

The geologic setting and history, along with observations through 50 years of detailed geologic field work, show that large-displacement (i.e., greater than 30 meters of displacement) syn- to post-volcanic faults are rare in the Rainier Mesa area. Faults observed in tunnels and drill holes are mostly tight, with small displacements (most less than 1.5 meters) and small associated damage zones. Faults are much more abundant in the zeolitized tuffs than in the overlying vitric tuffs, and there is little evidence that faults extend downward from the tuff section through the argillic paleocolluvium into pre-Tertiary rocks. The differences in geomechanical characteristics of the various tuff lithologies at Rainier Mesa suggest that most faults on Rainer Mesa are limited to the zeolitic units sandwiched between the overlying vitric bedded tuffs and the underlying pre-Tertiary units (lower carbonate aquifer–3, lower clastic confining unit–1, and Mesozoic granite confining unit).

Drellack, S.L.; Prothro, L.B.; Townsend, M.J.; Townsend, D.R.

2011-02-01T23:59:59.000Z

158

Development of secondary faults between en echelon, oblique-slip faults: examples from basement controlled, small-fault systems in the Llano Uplift of central Texas  

E-Print Network [OSTI]

between and oriented oblique to the bounding faults. With increasing displacement on the bounding faults, the system of secondary faults evolves from an Elementary to a Compound, to an Advanced geometry, which includes the formation of secondary... to the primary faults. Synthetic faults form interior to and ahead of the bounding faults, increasing the effective overlap. Displacements on antithetic faults are directly related to changes in displacement on associated bounding faults. Additionally...

Hedgcoxe, Howard Reiffert

2012-06-07T23:59:59.000Z

159

Termination of a Major Normal Fault | Open Energy Information  

Open Energy Info (EERE)

Termination of a Major Normal Fault: Major normal fault terminations or tip-lines sometimes split into multiple closely-spaced faults that result in increased...

160

Scientific drilling into the San Andreas fault and site characterization research: Planning and coordination efforts. Final technical report  

SciTech Connect (OSTI)

The fundamental scientific issue addressed in this proposal, obtaining an improved understanding of the physical and chemical processes responsible for earthquakes along major fault zones, is clearly of global scientific interest. By sampling the San Andreas fault zone and making direct measurements of fault zone properties to 4.0 km at Parkfield they will be studying an active plate-boundary fault at a depth where aseismic creep and small earthquakes occur and where a number of the scientific questions associated with deeper fault zone drilling can begin to be addressed. Also, the technological challenges associated with drilling, coring, downhole measurements and borehole instrumentation that may eventually have to be faced in deeper drilling can first be addressed at moderate depth and temperature in the Parkfield hole. Throughout the planning process leading to the development of this proposal they have invited participation by scientists from around the world. As a result, the workshops and meetings they have held for this project have involved about 350 scientists and engineers from about a dozen countries.

Zoback, M.D.

1998-08-30T23:59:59.000Z

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Fault block kinematics at a releasing stepover of the Eastern California  

Open Energy Info (EERE)

block kinematics at a releasing stepover of the Eastern California block kinematics at a releasing stepover of the Eastern California shear zone: Partitioning of rotation style in and around the Coso geothermal area and nascent metamorphic core complex Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Fault block kinematics at a releasing stepover of the Eastern California shear zone: Partitioning of rotation style in and around the Coso geothermal area and nascent metamorphic core complex Details Activities (1) Areas (1) Regions (0) Abstract: Pliocene lavas and sediments of Wild Horse Mesa in the Coso Range, CA exhibit clockwise vertical-axis rotation of fault-bounded blocks. This indicates localization of one strand of the Eastern California shear zone/Walker Lane Belt within a large-scale, transtensional, dextral,

162

Category:Green Bay, WI | Open Energy Information  

Open Energy Info (EERE)

WI WI Jump to: navigation, search Go Back to PV Economics By Location Media in category "Green Bay, WI" The following 16 files are in this category, out of 16 total. SVFullServiceRestaurant Green Bay WI Wisconsin Electric Power Co.png SVFullServiceRestauran... 79 KB SVQuickServiceRestaurant Green Bay WI Wisconsin Electric Power Co.png SVQuickServiceRestaura... 79 KB SVHospital Green Bay WI Wisconsin Electric Power Co.png SVHospital Green Bay W... 79 KB SVLargeHotel Green Bay WI Wisconsin Electric Power Co.png SVLargeHotel Green Bay... 78 KB SVLargeOffice Green Bay WI Wisconsin Electric Power Co.png SVLargeOffice Green Ba... 90 KB SVMediumOffice Green Bay WI Wisconsin Electric Power Co.png SVMediumOffice Green B... 78 KB SVMidriseApartment Green Bay WI Wisconsin Electric Power Co.png

163

Climate Zone Number 2 | Open Energy Information  

Open Energy Info (EERE)

2 is defined as 2 is defined as Hot - Humid(2A) with IP Units 6300 < CDD50ºF ≤ 9000 and SI Units 3500 < CDD10ºC ≤ 5000 Dry(2B) with IP Units 6300 < CDD50ºF ≤ 9000 and SI Units 3500 < CDD10ºC ≤ 5000 . The following places are categorized as class 2 climate zones: Acadia Parish, Louisiana Alachua County, Florida Allen Parish, Louisiana Anderson County, Texas Angelina County, Texas Appling County, Georgia Aransas County, Texas Ascension Parish, Louisiana Assumption Parish, Louisiana Atascosa County, Texas Atkinson County, Georgia Austin County, Texas Avoyelles Parish, Louisiana Bacon County, Georgia Baker County, Florida Baker County, Georgia Baldwin County, Alabama Bandera County, Texas Bastrop County, Texas Bay County, Florida Beauregard Parish, Louisiana Bee County, Texas

164

Modern technology in an old area - Bay Marchand field revisited  

SciTech Connect (OSTI)

Bay Marchand Field, a giant Gulf of Mexico oil field discovered in 1949, is undergoing renewed drilling activity as the result of a three-dimensional (3-D) seismic survey. The field, situated over a large salt diapir, is characterized by complex fault systems and typical Gulf Coast regressive sedimentation. As of 1989, over 700 wells had produced 518 MMBO and 379 bcfg of gas from the field. The 3-D survey covers over 60 mi{sup 2} and was shot for the following objectives; (1) to delineate new pools, (2) to review mature areas for additional development opportunities, and (3) to assist in reservoir management. Geophysically, the survey was designed to cover all common-depth-point bins and to provide for maximum horizontal and vertical resolution. The difficulty of obtaining such full coverage was heightened by numerous surface facilities dotting the field. But the data were successfully acquired through state-of-the-art techniques. To date, structural interpretation of the survey has led to a better definition of the salt/sediment interface and good correlation of fault patterns and the resulting reservoir geometries. Stratigraphically, better understanding of paleoenvironments, log correlations, and sand distribution has resulted. The benefits of these improvements are manifested in several new successful wells in both mature and undeveloped portions of the field as well as the recognition that other wells are now no longer necessary. Also, secondary recovery programs, specifically waterfloods, are being improved. The result will be an increase in total reserves as well as daily production.

Abriel, W.L.; Neale, P.S.; Tissue, J.S.; Wright, R.M. (Chevron U.S.A., New Orleans, LA (USA))

1990-05-01T23:59:59.000Z

165

Aseismic Slip Events along the Southern San Andreas Fault System Captured by Radar Interferometry  

SciTech Connect (OSTI)

A seismic slip is observed along several faults in the Salton Sea and southernmost Landers rupture zone regions using interferometric synthetic aperture radar (InSAR) data spanning different time periods between 1992 and 1997. In the southernmost Landers rupture zone, projecting south from the Pinto Mountain Fault, sharp discontinuities in the interferometric phase are observed along the sub-parallel Burnt Mountain and Eureka Peak Faults beginning three months after the Landers earthquake and is interpreted to be post-Landers after-slip. Abrupt phase offsets are also seen along the two southernmost contiguous 11 km Durmid Hill and North Shore segments of the San Andreas Fault with an abrupt termination of slip near the northern end of the North Shore Segment. A sharp phase offset is seen across 20 km of the 30 km-long Superstition Hills Fault before phase decorrelation in the Imperial Valley along the southern 10 km of the fault prevents coherent imaging by InSAR. A time series of deformation interferograms suggest most of this slip occurred between 1993 and 1995 and none of it occurred between 1992 and 1993. A phase offset is also seen along a 5 km central segment of the Coyote Creek fault that forms a wedge with an adjoining northeast-southwest trending conjugate fault. Most of the slip observed on the southern San Andreas and Superstition Hills Faults occurred between 1993 and 1995--no slip is observed in the 92-93 interferograms. These slip events, especially the Burnt Mountain and Eureka Peak events, are inferred to be related to stress redistribution from the June, 1992 M{sub w} = 7.3 Landers earthquake. Best-fit elastic models of the San Andreas and Superstition Hills slip events suggest source mechanisms with seismic moments over three orders of magnitude larger than a maximum possible summation of seismic moments from all seismicity along each fault segment during the entire 4.8-year time interval spanned by the InSAR data. Aseismic moment releases of this magnitude (equivalent to M{sub w} = 5.3 and 5.6 events on the Superstition Hills and San Andreas Faults respectively) are hitherto unknown and have not been captured previously by any geodetic technique.

Vincent, P

2001-10-01T23:59:59.000Z

166

Quaternary faults of west Texas  

SciTech Connect (OSTI)

North- and northwest-striking intermontane basins and associated normal faults in West Texas and adjacent Chihuahua, Mexico, formed in response to Basin and Range tectonism that began about 24 Ma ago. Data on the precise ages of faulted and unfaulted Quaternary deposits are sparse. However, age estimates made on the basis of field stratigraphic relationships and the degree of calcic soil development have helped determine that many of the faults that bound the basin margins ruptured since the middle Pleistocene and that some faults probably ruptured during the Holocene. Average recurrence intervals between surface ruptures since the middle Pleistocene appear to be relatively long, about 10,000 to 100,000 yr. Maximum throw during single rupture events have been between 1 and 3 m. Historic seismicity in West Texas is low compared to seismicity in many parts of the Basin and Range province. The largest historic earthquake, the 1931 Valentine earthquake in Ryan Flat/Lobo Valley, had a magnitude of 6.4 and no reported surface rupture. The most active Quaternary faults occur within the 120-km-long Hueco Bolson, the 70-km-long Red Light Bolson, and the > 200-km-long Salt Basins/Wild Horse Flat/Lobo Valley/Ryan Flat.

Collins, E.W.; Raney, J.A. (Univ. of Texas, Austin, TX (United States). Bureau of Economic Geology)

1993-04-01T23:59:59.000Z

167

Renaissance Zones (North Dakota)  

Broader source: Energy.gov [DOE]

Renaissance Zones allow qualifying businesses and individuals to claim one or more tax incentives for purchasing, leasing, or making improvements to real property located in a North Dakota...

168

Felton Bay Logistics, LLC | Open Energy Information  

Open Energy Info (EERE)

Felton Bay Logistics, LLC Felton Bay Logistics, LLC Jump to: navigation, search Logo: Felton Bay Logistics, LLC Name Felton Bay Logistics, LLC Place San Diego Zip 92115 Sector Services Product Strategies for Sustainability Year founded 2010 Number of employees 1-10 Website http://www.feltonbay.com Coordinates 32.7612759°, -117.0735241° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":32.7612759,"lon":-117.0735241,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

169

Bristol Bay Geothermal Area | Open Energy Information  

Open Energy Info (EERE)

Bristol Bay Geothermal Area Bristol Bay Geothermal Area Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Geothermal Resource Area: Bristol Bay Geothermal Area Contents 1 Area Overview 2 History and Infrastructure 3 Regulatory and Environmental Issues 4 Exploration History 5 Well Field Description 6 Geology of the Area 7 Geofluid Geochemistry 8 NEPA-Related Analyses (1) 9 Exploration Activities (0) 10 References Area Overview Geothermal Area Profile Location: Bristol Bay Borough, Alaska Exploration Region: Alaska Geothermal Region GEA Development Phase: none"None" is not in the list of possible values (Phase I - Resource Procurement and Identification, Phase II - Resource Exploration and Confirmation, Phase III - Permitting and Initial Development, Phase IV - Resource Production and Power Plant Construction) for this property.

170

Tuscola Bay Wind | Open Energy Information  

Open Energy Info (EERE)

Tuscola Bay Wind Tuscola Bay Wind Jump to: navigation, search Name Tuscola Bay Wind Facility Tuscola Bay Wind Sector Wind energy Facility Type Commercial Scale Wind Facility Status In Service Owner NextEra Energy Resources Developer NextEra Energy Resources Energy Purchaser Detroit Edison Location Fairgrove MI Coordinates 43.52596°, -83.653106° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":43.52596,"lon":-83.653106,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

171

Chesapeake Bay Test Site | Open Energy Information  

Open Energy Info (EERE)

Chesapeake Bay Test Site Chesapeake Bay Test Site Jump to: navigation, search Name Chesapeake Bay Test Site Facility Chesapeake Bay Test Site Sector Wind energy Facility Type Offshore Wind Facility Status Proposed Owner Gamesa and Newport News Energy Developer Gamesa and Newport News Energy Location Atlantic Ocean VA Coordinates 37.243°, -76.062° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":37.243,"lon":-76.062,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

172

Muon Simulation at the Daya Bay SIte  

E-Print Network [OSTI]

Muon simulation at the Daya Bay site Guan Mengyun ? Caowe simulated the underground muon background at the Daya Baysite. To get the sea-level muon ?ux parameteri- zation, a

Mengyun, Guan

2011-01-01T23:59:59.000Z

173

Paleoseismic investigations of the Paintbrush Canyon fault in southern Midway Valley, Yucca Mountain, Nevada: Preliminary results  

SciTech Connect (OSTI)

Trench mapping in southern Midway Valley provides evidence of multiple surface-faulting events on a western splay of the Paintbrush Canyon fault during the middle to late Pleistocene. The 6-m-wide fault zone exposed in the trench strikes N30-45E and dips steeply ([approximately]78[degree]) to the west, although some shears within the zone dip to the east. Tertiary volcanic bedrock is exposed only on the footwall block within the trench. Unconsolidated colluvial and eolian deposits are present in the hanging-wall block and above bedrock in the footwall block. These deposits tentatively are assigned, respectively, mid Pleistocene and late Pleistocene ages based on correlations with surficial map units in Midway Valley. Three to five displacement events are inferred based on faulted colluvial and eolian deposits, and scarp-derived colluvial wedges. Total cumulative dip-slip displacement of the oldest middle Pleistocene subunit is estimated to be about 170 to 270 cm. The dip-slip displacement associated with the youngest event is about 15 cm. The earlier displacements are estimated to have produced between 40 and 85 cm of dip-slip displacement per event. The most recent event occurred after deposition of late Pleistocene colluvium deposited against the fault scarp but before deposition of an overlying hillslope-derived colluvium of probable late pleistocene age. Based on the preliminary results of the authors study, the middle to late Quaternary rate of dip-slip displacement is approximately 0.01 m/kyr or less. Ongoing work, including soil-stratigraphic studies and numerical dating of deposits, should better constrain the timing and a rate of faulting along this western splay of the Paintbrush Canyon fault.

Swan, F.H.; Wesling, J.R.; Thomas, A.P. (Geomatrix Consultants, San Francisco, CA (United States))

1993-04-01T23:59:59.000Z

174

Mercury bioaccumulation in Lavaca Bay, Texas  

E-Print Network [OSTI]

MERCURY BIOACCUMULATION IN LAVACA BAY, TEXAS A Thesis by SALLY JO PALMER Submitted to the Office of Graduate Studies of Texas ABM University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE August 1992 Major... Subject: Oceanography MERCURY BIOACCUMULATION IN LAVACA BAY, TEXAS A Thesis by SALLY JO PALMER Approved as to style and content by: obby J. Pr y (Chair of Committee) Robe J. Tayl (Member) owell (Member) Marvin W. Rowe (Member) Gi bert T. Rowe...

Palmer, Sally Jo

2012-06-07T23:59:59.000Z

175

Sedimentary parameters of upper Barataria Bay, Louisiana  

E-Print Network [OSTI]

upon oonditions of sedimentation is exerted by currents set in motion 'by oceanic tides. Tidal activity causes sediment to be introduced into the upper bay and controls its distribution. A modifying influence i. s exerted by the influx of fresh... Classification and Distribution of Sediment Types Anomalous Areas CONDITIONS OF SEDIMENTATION Bathymetry Signifioance of Parameter Distribution Patterns Marginal areas Central bay Marginal embayments . ~ Environments of Deposition . CONCLUSIONS...

Siegert, Rudolf B

2012-06-07T23:59:59.000Z

176

The construction of the Browns Bay Vessel  

E-Print Network [OSTI]

INVESTIGATIVE TECHNIQUES. 10 19 The Site. National Historic Sites Service Excavation and Raising of the Vessel Vessel on Display. The Vessel in 1985. 19 20 27 28 Method of Recording III THE CONSTRUCTION OF THE VESSEL 31 36 The Keel 36 The Stem... A flat-bottomed boat being built. 17 9 Forelocked eye-bolts from the midship beam of the Browne Bay Vessel 21 10 Broad arrow stamped in an eye-bolt from the Browns Bay Vessel. . . . . . . . . . . . . . . . . . . . . . . . . . . 22 11 Pulley...

Amer, Christopher Francis

2012-06-07T23:59:59.000Z

177

Definition: Fault Current Limiter | Open Energy Information  

Open Energy Info (EERE)

Limiter Limiter Jump to: navigation, search Dictionary.png Fault Current Limiter A fault current limiter prevents current in an electrical circuit from exceeding a predetermined level by increasing the electrical impedance of that circuit before the current through the circuit exceeds that level. Fault current limiters are designed so as to minimize the impedance of the circuit under normal conditions to reduce losses, but increase the impedance of the circuit under fault conditions to limit fault current.[1] View on Wikipedia Wikipedia Definition A Fault Current Limiter (FCL) is a device which limits the prospective fault current when a fault occurs (e.g. in a power transmission network). The term includes superconducting devices and non-superconducting devices, however some of the more simple non-superconducting devices (such

178

Definition: Fault Current Limiting | Open Energy Information  

Open Energy Info (EERE)

Limiting Limiting Jump to: navigation, search Dictionary.png Fault Current Limiting Fault current limiting can be achieved through sensors, communications, information processing, and actuators that allow the utility to use a higher degree of network coordination to reconfigure the system to prevent fault currents from exceeding damaging levels. Fault current limiting can also be achieved through the implementation of special stand alone devices known as Fault Current Limiters (FCLs) which act to automatically limit high through currents that occur during faults.[1] Related Terms fault, fault current limiter References ↑ SmartGrid.gov 'Description of Functions' Temp LikeLike UnlikeLike You like this.Sign Up to see what your friends like. late:ISGANAttributionsmart grid,smart grid,smart grid,smart grid,

179

Development of Superconducting AC Fault Current Limiter  

Science Journals Connector (OSTI)

The authors have developed a new superconducting fault current limiter whose impedance during normal operation is very small. During fault conditions, the limiter behaves as a superconducting reactor. The limiter

Daisuke Ito; Eriko Yoneda; Tsutomu Fujioka…

1990-01-01T23:59:59.000Z

180

Test on Superconducting AC Fault Current Limiter  

Science Journals Connector (OSTI)

The authors have developed a new superconducting fault current limiter whose impedance during normal operation is very small. During fault conditions, the limiter behaves as a superconducting reactor. The limiter

Daisuke Ito; Eriko S. Yoneda…

1990-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Climate Zones Robinson Projection  

E-Print Network [OSTI]

Climate Zones Africa ´Robinson Projection Copyright 2007. The Trustees of Columbia University University. Population, Landscape, and Climate Estimates (PLACE). Further information available at: http://sedac.ciesin.columbia.edu/place/ Publish Date: 03/13/07 0 500 km Climate zones were taken from the Köppen Climate Classification map

Columbia University

182

Extending the range of applicability of HTS cylinders in inductive superconducting fault current limiters  

Science Journals Connector (OSTI)

In the numerical routine used to estimate the temperature of the weak zones (channels) an error was introduced. Once the error is eliminated, the improvement in the thermal refrigeration of the inductive fault current limiters with artificial weak zones still remains but its importance is reduced; a channelled cylinder can refrigerate faster than a non-channelled one, as heat is removed also by conduction to the cold parts, but under a current fault the temperature of the weak zones is very much above those displayed in figure 3(b) and figure 4 (140 K is our best result, Tc being 105 K). As a consequence, the channelled cylinder needs about 9 s to get the critical temperature for the nominal current, whereas the non-channelled cylinder requires more than 15 s (both refrigerated by liquid nitrogen). Although appreciable, this improvement is still far from the usually required recovery time, which is about 1 s. This design could be more appropriate for a fault current limiter working in a slightly lower power grid or in a gaseous atmosphere, where the channelled sample is definitely much better than the non-channelled cylinder. To be competitive when operating in liquid nitrogen some additional mechanism should be implemented to avoid the excessive heating of the weak zones.

M R Osorio; J A Lorenzo; J A Veira; F Vidal

2008-01-01T23:59:59.000Z

183

Fault tolerant supercomputing: a software approach  

Science Journals Connector (OSTI)

Adding fault tolerance to embedded supercomputing applications is becoming an issue of great significance, especially as these applications support critical parts of our everyday life in the modern "Information Society". To this end, a software middleware ... Keywords: embedded parallel and distributed systems, fault-tolerant communication, high performance computing, maintainability, separation of design concerns, software fault tolerance, user-specified recovery strategies

E. Verentziotis; T. Varvarigou; D. Vergados; G. Deconinck

2001-01-01T23:59:59.000Z

184

Fault-tolerant TCP mechanisms  

E-Print Network [OSTI]

While fault-tolerance is supported by a variety of critical services that can be accessed over the Internet, they are not robust in that they are oblivious of the impact of their tolerant mechanisms on the service they deliver. Throughputs and fail...

Satapati, Suresh Kumar

2012-06-07T23:59:59.000Z

185

Deep Vadose Zone Field Activities  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

HANFORD ADVISORY BOARD, RAP March 6, 2013 Presented by: John Morse DEEP VADOSE ZONE ACTIVITIES Page 2 Deep Vadose Zone Areas Page 3 Deep Vadose Zone Field Activities FY 2014...

186

An unknown active fault revealed by microseismicity in the south-east Francoise Courboulex, Christophe Larroque, Anne Deschamps, Celine Gelis,  

E-Print Network [OSTI]

oceanic basin (Figure 1). The southern French Alps are part of the broad plate boundary zone between in the south-east of France in December 2000, about 15 km north of the densely populated cities of the French between the southern French Alps and the Ligurian Basin, several faults are supposed to be seismogenic (e

Vallée, Martin

187

Historic Surface Faulting and Paleoseismicity in the Area of the 1954  

Open Energy Info (EERE)

Historic Surface Faulting and Paleoseismicity in the Area of the 1954 Historic Surface Faulting and Paleoseismicity in the Area of the 1954 Rainbow Mountain-Stillwater Earthquake Sequence, Central Nevada Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Historic Surface Faulting and Paleoseismicity in the Area of the 1954 Rainbow Mountain-Stillwater Earthquake Sequence, Central Nevada Abstract The Rainbow Mountain area was the site of three surface-rupturing earthquakes on 6 July and 23 August 1954. More than 50 field measurements of surface offsets constrain the distribution of slip along the discontinuous and distributed rupture zone that formed during the earthquake sequence. Vertical offsets reach a maximum of ~0.8 m with the average vertical offset being ~0.2 m. In contrast to original reports, we

188

Intersecting Fault Trends and Crustal-Scale Fluid Pathways Below the Dixie  

Open Energy Info (EERE)

Intersecting Fault Trends and Crustal-Scale Fluid Pathways Below the Dixie Intersecting Fault Trends and Crustal-Scale Fluid Pathways Below the Dixie Valley Geothermal Area, Nevada, Inferred from 3d Magnetotelluric Surveying Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Intersecting Fault Trends and Crustal-Scale Fluid Pathways Below the Dixie Valley Geothermal Area, Nevada, Inferred from 3d Magnetotelluric Surveying Abstract Geothermal systems may occur in zones of structural dilatency which create the crustal plumbing that al-lows concentration of high-temperature fluids from surrounding volumes. While structural orientations of the U.S. Great Basin are dominated visually by the NNE-oriented horst-graben morphology, other alignments are apparent, perhaps principally a NNW-trending grain

189

Development Opportunity Zone Credit  

Broader source: Energy.gov [DOE]

The Development Opportunity Zone Credits incent new and expanding businesses in the Cities of Beloit, Janesville and Kenosha by providing non-refundable tax credits to assist with the creation and...

190

Deep Vadose Zone  

Broader source: Energy.gov [DOE]

The Mission of the Deep Vadose Zone Applied Field Research Initiative is to protect water resources across the DOE complex over the long-term by developing effective solutions to solve DOE’s most...

191

Hooper Bay Wind Farm | Open Energy Information  

Open Energy Info (EERE)

Hooper Bay Wind Farm Hooper Bay Wind Farm Jump to: navigation, search Name Hooper Bay Wind Farm Facility Hooper Bay Sector Wind energy Facility Type Commercial Scale Wind Facility Status In Service Owner Alaska Village Electric Coop (AVEC) Developer Alaska Village Electric Coop (AVEC) Energy Purchaser Alaska Village Electric Coop (AVEC) Location Hooper Bay AK Coordinates 61.53572°, -166.097182° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":61.53572,"lon":-166.097182,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

192

Cleveland Bay Wind Farm | Open Energy Information  

Open Energy Info (EERE)

Cleveland Bay Wind Farm Cleveland Bay Wind Farm Jump to: navigation, search Name Cleveland Bay Wind Farm Facility Cleveland Bay Wind Farm Sector Wind energy Facility Type Offshore Wind Facility Status Proposed Developer Lake Erie Energy Development Corporation / Great Lakes Ohio Wind / Great Lakes Energy Wind LLC / Freshwater Wind LLC / Cavallo Great Lakes Ohio Wind LLC Location Cleveland Bay OH Coordinates 41.608°, -81.809° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.608,"lon":-81.809,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

193

Queen Anne's County- Solar Zoning  

Broader source: Energy.gov [DOE]

Queen Anne's County zoning code allows for ground mounted solar arrays in areas zoned as "open space," "agricultural," and "countryside" districts.

194

New and Underutilized Technology: Efficient High Bay Fluorescent Lighting |  

Broader source: Energy.gov (indexed) [DOE]

Efficient High Bay Fluorescent Efficient High Bay Fluorescent Lighting New and Underutilized Technology: Efficient High Bay Fluorescent Lighting October 7, 2013 - 8:54am Addthis The following information outlines key deployment considerations for efficient high bay fluorescent lighting within the Federal sector. Benefits Efficient high bay fluorescent lighting can include either T5 or T8 fluorescent lighting systems for high-bay applications currently using metal halide fixtures. Fluorescent fixtures offer better light distribution, better light maintenance over the life of the lamp, improved color quality, and on-off control (re-strike time) with lower energy consumption. Application Efficient high bay fluorescent lighting is applicable for facilities containing high bay areas. Key Factors for Deployment

195

TOURISM IN GOLDEN BAY Economic Impacts & Resource Use Issues  

E-Print Network [OSTI]

TOURISM IN GOLDEN BAY Economic Impacts & Resource Use Issues - Preliminary Report - June 2000 NZ Tourism Research Institute Victoria University of Wellington Auckland University of Technology #12;INTRODUCTION Golden Bay's tourism industry faces a number of pressing issues. Intensifying competition

196

Glacier Bay Inc | Open Energy Information  

Open Energy Info (EERE)

Glacier Bay Inc Glacier Bay Inc Jump to: navigation, search Name Glacier Bay Inc Place Oakland, California Zip 94601 Product US-based, advanced thermal control, sound reduction, and DC power management technologies developer. Coordinates 37.805065°, -122.273024° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":37.805065,"lon":-122.273024,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

197

Mercury Concentrations in Fish from the San Francisco Bay Area  

E-Print Network [OSTI]

Mercury Concentrations in Fish from the San Francisco Bay Area San Francisco Bay Regional Water on composite samples · Some mercury analysis on individual largemouth bass · Size targets #12;Tomales Bay Study chemical analyses (Hg and organics) conducted on composite samples · Some mercury analysis on individual

198

THERMOFLUID OPTIMIZATION OF A HEATED HELICOPTER ENGINE COOLING BAY SURFACE  

E-Print Network [OSTI]

effectiveness of an aircraft de-icing strategy by re-designing the cooling bay surface shape. The design of a helicopter cooling bay can be ice prone under certain atmospheric conditions. Its effective shape design1 THERMOFLUID OPTIMIZATION OF A HEATED HELICOPTER ENGINE COOLING BAY SURFACE D. Wang 1 , G. F

Wang, Gaofeng Gary

199

MODELING NEKTON HABITAT USE IN GALVESTON BAY, TEXAS  

E-Print Network [OSTI]

MODELING NEKTON HABITAT USE IN GALVESTON BAY, TEXAS: AN APPROACH TO DEFINE ESSENTIAL FISH HABITAT IN GALVESTON BAY, TEXAS: AN APPROACH TO DEFINE ESSENTIAL FISH HABITAT (EFH) Project Team: Randall D. Clark.A. Matthews. 1999. Modeling nekton habitat selection in Galveston Bay, Texas: An approach to define essential

200

Segmentation development for Galveston Bay. Final report  

SciTech Connect (OSTI)

The purpose of the study is to develop a segmentation scheme for the Galveston Bay System that will facilitate the other efforts planned by the Galveston Bay National Estuary Program (GBNEP). The study is organized around four tasks: (1) the evaluation of existing segmentation schemes, (2) evaluation of natural features and anthropogenic inputs, (3) determination of segmentation criteria, (4) and the drafting of the boundaries. To facilitate the management and presentation of the large amounts of geobased data accumulated, a geographic information system (GIS) was developed for the study area.

Not Available

1992-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

A fault location approach for fuzzy fault section estimation on radial distribution feeders  

E-Print Network [OSTI]

measured at feeder substations and the fault distance algorithm was tested using data obtained by staging faults on a model of an overhead feeder using EMTP/ATP simulation. The results obtained from the tests were promising. A simple illustration...

Andoh, Kwame Sarpong

2012-06-07T23:59:59.000Z

202

Optimal power flow considering fault current level constraints and fault current limiters  

Science Journals Connector (OSTI)

Abstract The aim of this paper is to present a novel method to dispatch the active generation power properly in the power system while incorporating fault current levels as constraints for the optimization problem. Due to the limited capacity of protective devices such as circuit breakers, allocating active power without considering fault current levels can probably lead to fault currents exceeding the rating of these devices. Hence restricting the fault current levels to an allowable amount while minimizing a specified objective function seems to be necessary. In a number of cases even the appropriate allocation of active power is not able to reduce the fault current levels to the permitted amount therefore using fault current limiters (FCL) is unavoidable. In this paper also a planning scheme is presented for the location and sizing of fault current limiters and the effect of fault current limiters on the objective functions is investigated.

Amirhossein Khazali; Mohsen Kalantar

2014-01-01T23:59:59.000Z

203

An algorithm for faulted phase and feeder selection under high impedance fault conditions  

E-Print Network [OSTI]

substation. One-line diagram of a distribution system with two feeders. Typical high impedance fault, showing little or no change in phase voltage due to the fault. . Phase voltage and high frequency current component during a staged high impedance... substation. One-line diagram of a distribution system with two feeders. Typical high impedance fault, showing little or no change in phase voltage due to the fault. . Phase voltage and high frequency current component during a staged high impedance...

Benner, Carl Lee

2012-06-07T23:59:59.000Z

204

Ground motion modeling of Hayward fault scenario earthquakes II:Simulation of long-period and broadband ground motions  

SciTech Connect (OSTI)

We simulate long-period (T > 1.0-2.0 s) and broadband (T > 0.1 s) ground motions for 39 scenarios earthquakes (Mw 6.7-7.2) involving the Hayward, Calaveras, and Rodgers Creek faults. For rupture on the Hayward fault we consider the effects of creep on coseismic slip using two different approaches, both of which reduce the ground motions compared with neglecting the influence of creep. Nevertheless, the scenario earthquakes generate strong shaking throughout the San Francisco Bay area with about 50% of the urban area experiencing MMI VII or greater for the magnitude 7.0 scenario events. Long-period simulations of the 2007 Mw 4.18 Oakland and 2007 Mw 4.5 Alum Rock earthquakes show that the USGS Bay Area Velocity Model version 08.3.0 permits simulation of the amplitude and duration of shaking throughout the San Francisco Bay area, with the greatest accuracy in the Santa Clara Valley (San Jose area). The ground motions exhibit a strong sensitivity to the rupture length (or magnitude), hypocenter (or rupture directivity), and slip distribution. The ground motions display a much weaker sensitivity to the rise time and rupture speed. Peak velocities, peak accelerations, and spectral accelerations from the synthetic broadband ground motions are, on average, slightly higher than the Next Generation Attenuation (NGA) ground-motion prediction equations. We attribute at least some of this difference to the relatively narrow width of the Hayward fault ruptures. The simulations suggest that the Spudich and Chiou (2008) directivity corrections to the NGA relations could be improved by including a dependence on the rupture speed and increasing the areal extent of rupture directivity with period. The simulations also indicate that the NGA relations may under-predict amplification in shallow sedimentary basins.

Aagaard, B T; Graves, R W; Rodgers, A; Brocher, T M; Simpson, R W; Dreger, D; Petersson, N A; Larsen, S C; Ma, S; Jachens, R C

2009-11-04T23:59:59.000Z

205

Fagatele Bay National Marine Sanctuary GIS Capacity  

E-Print Network [OSTI]

Report, configuration notes American Samoa Spatial Data Infrastructure Maps GIS Data CDs Operating System, a number of issues regarding map projections and datums were resolved allowing GIS users to processFagatele Bay National Marine Sanctuary GIS Capacity Binder Index Background 2 Hardware, Software

Wright, Dawn Jeannine

206

Summary of Superconducting Fault Current Limiter Technology  

Science Journals Connector (OSTI)

In recent years, superconducting fault current limiter (SFCL) has become one of the forefront topics of current-limiting technology in the world. In this...

Linmang Wang; Pengzan Jiang; Dada Wang

2012-01-01T23:59:59.000Z

207

Research on Fault Analysis and Fault-Tolerant Control of EV/HEV Powertrain  

E-Print Network [OSTI]

presents research works in the topics of fault analysis and fault tolerant control of an electric vehicle mechanism (transition strategy) at sensor fault occurrence. Index Terms--Electric vehicle, induction motor-tolerant AC motor drives in industrial applications [9-10- 41]. II. ELECTRIC VEHICLE POWERTRAIN COMPONENTS

Brest, Université de

208

Structural Heterogeneity and Permeability in Faulted Eolian Sandstone: Implications for Subsurface Modeling of Faults  

Science Journals Connector (OSTI)

...fault that could be hydraulically significant in a reservoir...Reynolds and E. D. Dolly, eds., Mesozoic paleogeography...Jones, 1998, Fault-controlled communication in the...Reynolds and E. D. Dolly, eds., Mesozoic paleogeog-raphy...Jones, 1998, Fault-controlled communication in theSleipner...

Zoe K. Shipton; James P. Evans; Kim R. Robeson; Craig B. Forster; Stephen Snelgrove

209

Unsaturated Zone I. Overview  

E-Print Network [OSTI]

Chapter 2 Unsaturated Zone I. Overview If the Yucca Mountain site is deemed suitable for re of the extent of welding, the tuffs within the UZ at Yucca Mountain are grouped informally into hydrogeologic Yucca Mountain is illustrated in Figure 2-1 on page 14. A. Why UZ Was Chosen Initial studies of Yucca

210

Low-cost motor drive embedded fault diagnosis systems  

E-Print Network [OSTI]

Electric motors are used widely in industrial manufacturing plants. Bearing faults, insulation faults, and rotor faults are the major causes of electric motor failures. Based on the line current analysis, this dissertation mainly deals with the low...

Akin, Bilal

2009-05-15T23:59:59.000Z

211

A transformer type fault current limiter with spark gap  

Science Journals Connector (OSTI)

A novel fault current limiter (FCL) is proposed in this paper. ... of the capacitor. During the short-circuit faults, the FCL resonantly produces a high impedance in the fault circuit after the breakdown of the s...

Zhang Xiaoqing; Ming Li

2010-06-01T23:59:59.000Z

212

Accurate resistive bridge fault modeling, simulation, and test generation  

E-Print Network [OSTI]

Resistive bridging faults in CMOS combinational circuits are studied in this work. Bridging faults are modeled using HSPICE circuit simulation of the various types of bridging faults that can occur in CMOS combinational circuits. The results...

Sar-Dessai, Vijay Ramesh

2012-06-07T23:59:59.000Z

213

Subduction Zone | Open Energy Information  

Open Energy Info (EERE)

Subduction Zone Subduction Zone Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Subduction Zone Dictionary.png Subduction Zone: A tectonic process in which one tectonic plate is forced beneath another and sinks into the mantle as the plates converge Other definitions:Wikipedia Reegle Tectonic Settings List of tectonic settings known to host modern geothermal systems: Extensional Tectonics Subduction Zone Rift Zone Hot Spot Non-Tectonic Strike-Slip A classic cartoon illustrating a typical simplified subduction zone. http://www.columbia.edu/~vjd1/subd_zone_basic.htm Subduction zones occur where one tectonic plate is pulled under another. Most often the subducting plate is oceanic crust and contains many hydrous minerals. As the oceanic plate subducts it dewaters into the mantle,

214

Evaluation of faulting characteristics and ground acceleration associated with recent movement along the Meers Fault, Southwestern Oklahoma  

E-Print Network [OSTI]

Recent studies have shown that a 27 km section of the Meers Fault was reactivated during Holocene time. Although these studies have proven the occurrence of recent fault activity, many basic characteristics of the faulting remain unresolved...

Burrell, Richard Dennis

2012-06-07T23:59:59.000Z

215

Off-fault Damage Associated with a Localized Bend in the North Branch San Gabriel Fault, California  

E-Print Network [OSTI]

and microstructural study focused on structural domains before, within, and after the fault bend on both sides of the fault. Subsidiary fault fabrics are similar in all domains outside the bend, which suggests a steady state fracture density and orientation...

Becker, Andrew 1987-

2012-08-15T23:59:59.000Z

216

An Assessment of Fault Current Limiter Testing Requirements ...  

Broader source: Energy.gov (indexed) [DOE]

An Assessment of Fault Current Limiter Testing Requirements An Assessment of Fault Current Limiter Testing Requirements The U.S. Department of Energy's (DOE) Office of Electricity...

217

fault diagnosis of a high voltage transmission line using waveform ...  

E-Print Network [OSTI]

Oct 4, 2013 ... FAULT DIAGNOSIS OF A HIGH VOLTAGE TRANSMISSION LINE USING ... Fault types such as single line to ground, line to line, double line to ...

Ripunjoy Phukan

2013-10-04T23:59:59.000Z

218

Development of a bridge fault extractor tool  

E-Print Network [OSTI]

Bhat, B. Tech, Indian Institute of Technology, Bombay Co-Chairs of Advisory Committee: Dr. D. M. H. Walker Dr. Jiang Hu Bridge fault extractors... Bhat, B. Tech, Indian Institute of Technology, Bombay Co-Chairs of Advisory Committee: Dr. D. M. H. Walker Dr. Jiang Hu Bridge fault extractors...

Bhat, Nandan D.

2005-02-17T23:59:59.000Z

219

FaultLocal Distributed Mending (Extended Abstract)  

E-Print Network [OSTI]

As communication networks grow, existing fault handling tools that involve global measures such as global time­outs or reset procedures become increasingly unaffordable, since their cost grows with the size of the network. Rather, for a fault handling mechanism to scale to large networks, its cost must depend only

Kutten, Shay

220

Building Technologies Office: Climate Zones  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Climate Zones to Climate Zones to someone by E-mail Share Building Technologies Office: Climate Zones on Facebook Tweet about Building Technologies Office: Climate Zones on Twitter Bookmark Building Technologies Office: Climate Zones on Google Bookmark Building Technologies Office: Climate Zones on Delicious Rank Building Technologies Office: Climate Zones on Digg Find More places to share Building Technologies Office: Climate Zones on AddThis.com... About Take Action to Save Energy Partner With DOE Activities Solar Decathlon Building America Research Innovations Research Tools Building Science Education Climate-Specific Guidance Solution Center Partnerships Meetings Publications Home Energy Score Home Performance with ENERGY STAR Better Buildings Neighborhood Program Challenge Home Guidelines for Home Energy Professionals

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Rift Zone | Open Energy Information  

Open Energy Info (EERE)

Rift Zone Rift Zone Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Rift Zone Dictionary.png Rift Zone: A divergent plate boundary within a continent Other definitions:Wikipedia Reegle Tectonic Settings List of tectonic settings known to host modern geothermal systems: Extensional Tectonics Subduction Zone Rift Zone Hot Spot Non-Tectonic Strike-Slip The Rio Grande Rift exemplifies rift zone tectonics - increased volcanic activity and the formation of graben structures (reference: science-art.com) Rift valleys occur at divergent plate boundaries, resulting in large graben structures and increased volcanism. The East African Rift is an example of a continental rift zone with increased volcanism, while the Atlantic's spreading Mid-Ocean Ridge is host to an enormous amount of geothermal

222

The Enterprise Zone (Rhode Island)  

Broader source: Energy.gov [DOE]

The Enterprise Zone offers tax incentives to business expanding their workforce by 5% at facilities in designated enterprise zones. The tax credit is equal to 50% of the annual wages paid to a new...

223

Enterprise Zone | Open Energy Information  

Open Energy Info (EERE)

Zone Jump to: navigation, search This article is a stub. You can help OpenEI by expanding it. Retrieved from "http:en.openei.orgwindex.php?titleEnterpriseZone&oldid542697"...

224

The Galactic Habitable Zone  

SciTech Connect (OSTI)

We propose the concept of a "Galactic Habitable Zone" (GHZ). Similar to the circumstellar habitable zone (CHZ), the GHZ is that region in a spiral galaxy where life can exist. The width of the GHZ is controlled by two factors. The inner (closest to the center of the galaxy) limit is set by threats to complex life: nearby transient sources of ionizing radiation and comet impacts. Such threats tend to increase close to the galactic center. The outer limit is imposed by galactic chemical evolution, specifically the abundance of heavier elements. Observation of stars in the Milky Way galaxy suggests that the outer reaches of a spiral galaxy may be too poor in heavy elements to allow terrestrial complex life to exist.

Guillermo Gonzalez

2009-08-21T23:59:59.000Z

225

Bay Front Biomass Facility | Open Energy Information  

Open Energy Info (EERE)

Front Biomass Facility Front Biomass Facility Jump to: navigation, search Name Bay Front Biomass Facility Facility Bay Front Sector Biomass Location Ashland County, Wisconsin Coordinates 46.9794969°, -90.4824892° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":46.9794969,"lon":-90.4824892,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

226

Alberta Health Services, Calgary Zone  

E-Print Network [OSTI]

Organizational Chart ­ AHS, Calgary Zone, Community, Rural and Mental Health Page 12 Organizational Chart ­ AHS, Calgary Zone, Addiction and Mental Health Page 13 Organizational Chart ­ AHS, Calgary Zone, Clinical specialty care clinics. 3) Increasing efficiency in our specialty clinics. 4) Standardizing care

Habib, Ayman

227

LNG carrier underwater noise in Baffin Bay  

Science Journals Connector (OSTI)

Large powerful liquid natural gas carriers may soon ply Arctic waters year round. Concern has been expressed over the impact the resulting noise will have on Arctic marine life. This study includes estimates of LNG carrier?radiated noise source levels and resulting sound levels at a given distance from the ship for a number of operating conditions. Measurements of sound propagation and ambient noise conditions in Baffin Bay are used to estimate the shipnoise levels in relation to the summertime noise background.

L. J. Leggat; H. M. Merklinger; J. L. Kennedy

1981-01-01T23:59:59.000Z

228

Marine geology of the Bay of Campeche  

E-Print Network [OSTI]

of Oceanography and Meteorology August, 1938 1 V .?> TABLE OF CONTENTS Page LIST OF F I G U R E S .......................... ............... v LIST OF TABLES............................................ vii LIST OF PLATES... STATION 11 AND STATION 30. . 17 6 BATHYMETRIC CHART OF THE BAY OF CAMPECHE.......... In V' Pocket YV.,;r? ' t. 7 BOTTOM PROFILES OF THE CONTINENTAL SLOPE ALONG 92?001 WEST LONGITUDE (A-A) OFF CAMPECHE BANK AND OF THE OUTER PORTION...

Creager, Joe S.

2013-10-04T23:59:59.000Z

229

New and Underutilized Technology: High Bay LED Lighting | Department of  

Broader source: Energy.gov (indexed) [DOE]

High Bay LED Lighting High Bay LED Lighting New and Underutilized Technology: High Bay LED Lighting October 7, 2013 - 8:55am Addthis The following information outlines key deployment considerations for high bay LED lighting within the Federal sector. Benefits LED light sources offer several potential benefits compared to metal halide or fluorescent lighting, including reduced energy consumption due to the ability to provide a more precise light distribution; longer operating life and lower maintenance requirements; less heat introduced into the space; and greater controllability for dimming and on/off control. Relevant to the cold storage application, LED performance improves in colder temperatures. Application High bay LED lighting is applicable for facilities containing high bay

230

BayWa Group | Open Energy Information  

Open Energy Info (EERE)

BayWa Group BayWa Group Jump to: navigation, search Name BayWa Group Place Munich, Germany Zip 81925 Sector Services, Solar Product Germany-based company with international operations specialised in wholesale and retail and in providing services. The company is also active in the biofuel and solar sectors. Coordinates 48.136415°, 11.577531° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":48.136415,"lon":11.577531,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

231

Fault-tolerant control for current sensors of doubly fed induction generators based on an improved fault detection method  

Science Journals Connector (OSTI)

Abstract Fault-tolerant control of current sensors is studied in this paper to improve the reliability of a doubly fed induction generator (DFIG). A fault-tolerant control system of current sensors is presented for the DFIG, which consists of a new current observer and an improved current sensor fault detection algorithm. The current observer is constructed by using only voltage signals as inputs. The fault detection algorithm is based on the current observer, in which an adaptive threshold and different fault duration times are considered. The performance of the proposed observer, improved fault detection algorithm, and fault-tolerant control system are investigated by simulation. The results indicate that the outputs of the observer and the sensor are highly coherent. The fault detection algorithm can efficiently detect both soft and hard faults in current sensors, and the fault-tolerant control system can effectively tolerate both types of faults.

H. Li; C. Yang; Y.G. Hu; B. Zhao; M. Zhao; Z. Chen

2014-01-01T23:59:59.000Z

232

Wetland plant communities, Galveston Bay system. Final report  

SciTech Connect (OSTI)

The report is the culmination of a field investigation of wetland plant communities, and is one phase of the project, Trends and Status of Wetland and Aquatic Habitats of the Galveston Bay System, Texas, sponsored by the Galveston Bay National Estuary Program. For purpose of the topical report, wetlands are defined and classified in terms of more classical definitions, for example, salt, brackish, and fresh marshes, in accordance with project requirements. More than 150 sites were examined in the Galveston Bay system.

White, W.A.; Paine, J.G.

1992-03-01T23:59:59.000Z

233

BayWa Sunways JV | Open Energy Information  

Open Energy Info (EERE)

Sunways JV Jump to: navigation, search Name: BayWa & Sunways JV Place: Germany Sector: Solar Product: Germany-based JV that specialises in developing, planning and realizing...

234

Chesapeake Bay, Drilling for Oil or Gas Prohibited (Virginia)  

Broader source: Energy.gov [DOE]

Drilling for oil or gas in the waters or within 500 hundred feet from the shoreline of the Chesapeake Bay or any of its tributaries is prohibited.

235

Control of hardwood regeneration in restored carolina bay depression wetlands.  

SciTech Connect (OSTI)

Carolina bays are depression wetlands located in the coastal plain region of the eastern United States. Disturbance of this wetland type has been widespread, and many sites contain one or more drainage ditches. Restoration of bays is of interest because they are important habitats for rare flora and fauna. Previous bay restoration projects have identified flood-tolerant woody competitors in the seedbank and re-sprouting as impediments to the establishment of desired herbaceous wetland vegetation communities. We restored 3 bays on the Savannah River Site, South Carolina, by plugging drainage ditches, harvesting residual pine/hardwood stands within the bays, and monitoring the vegetative response of the seedbank to the hydrologic change. We applied a foliar herbicide on one-half of each bay to control red maple (Acerrubrum), sweetgum (Liquidambar styraciflua), and water oak (Quercus nigra) sprouting, and we tested its effectiveness across a hydrologic gradient in each bay. Hardwood regeneration was partially controlled by flooding in bays that exhibited long growing season hydroperiods. The findings also indicated that herbicide application was an effective means for managing hardwood regeneration and re-sprouting in areas where hydrologic control was ineffective. Herbicide use had no effect on species richness in the emerging vegetation community. In late-season drawdown periods, or in bays where hydroperiods are short, more than one herbicide application may be necessary.

Moser, Lee, J.; Barton, Christopher, D.; Blake, John, I.

2012-06-01T23:59:59.000Z

236

ESnet, Orange Silicon Valley, and Bay Microsystems Demonstrate...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

ESnet, Orange Silicon Valley, and Bay Microsystems Demonstrate the World's First Long Distance 40Gbps RDMA Data Transfer News & Publications ESnet in the News ESnet News Media &...

237

The Effects of the "Ike Dike" barriers on Galveston Bay:.  

E-Print Network [OSTI]

??In 2008 Hurricane Ike flooded large parts of the barrier islands in front of the Galveston Bay near Houston, Texas. The storm surge also entered… (more)

Ruijs, M.

2011-01-01T23:59:59.000Z

238

Species diversity and water quality in Galveston bay, Texas  

Science Journals Connector (OSTI)

The relationships between species diversity of phytoplankton, zooplankton, nekton and benthos samples and the water quality of Galveston Bay, Texas were quantitatively compared. Two water quality parameters...

B. J. Copeland; Timothy J. Bechtel

1971-11-01T23:59:59.000Z

239

TRANSIENT PROCESSOR/BUS FAULT TOLERANCE FOR EMBEDDED SYSTEMS  

E-Print Network [OSTI]

TRANSIENT PROCESSOR/BUS FAULT TOLERANCE FOR EMBEDDED SYSTEMS With hybrid redundancy and data the schedule length overhead. Keywords: real-time embedded systems, safety-critical systems, transient faults, ecological, and/or financial disasters) that could result from a fault, these systems must be fault

Girault, Alain

240

Quantification of Priority-OR gates in temporal fault trees  

Science Journals Connector (OSTI)

Fault Tree Analysis has been used in reliability engineering for many decades and has seen various modifications to enable it to analyse fault trees with dynamic and temporal gates so it can incorporate sequential failure in its analysis. Pandora is ... Keywords: Markov chains, Monte Carlo, Pandora, dynamic fault trees, fault trees, safety

Ernest Edifor; Martin Walker; Neil Gordon

2012-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Intelligent fault prediction system based on internet of things  

Science Journals Connector (OSTI)

Fault prediction is the key technology to ensure the safe operation of large equipment. Based on the investigation of current and developing research of fault prediction, an intelligent fault prediction system based on internet of things is proposed ... Keywords: Fault prediction, Intelligent computer information processing, Internet of things, Mechanical equipment groups, Predictive maintenance

Xiaoli Xu; Tao Chen; Mamoru Minami

2012-09-01T23:59:59.000Z

242

History and Results of Surface Exploration in the Kilauea East Rift Zone |  

Open Energy Info (EERE)

History and Results of Surface Exploration in the Kilauea East Rift Zone History and Results of Surface Exploration in the Kilauea East Rift Zone Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: History and Results of Surface Exploration in the Kilauea East Rift Zone Abstract Government-funded surveys of the Kilauea East Rift Zone have resulted in a wealth of geophysical and geochemical data from an active volcanic area. All data are clearly of academic interest; Hawaii was used as a testing ground for various geophysical methods in the early days of geothermal exploration. Some surveys, such as gravity and magnetic, are useful a regional perspective for determining broad structural trends and grossly identifying magmatic intrusions. Seismic data are currently being used for a more sitespecific purpose: to determine fault locations and geometries.

243

Liquid zone seal  

DOE Patents [OSTI]

A seal assembly that provides a means for establishing multiple pressure zones within a system. The seal assembly combines a plate extending from the inner wall of a housing or inner enclosure that intersects with and is immersed in the fluid contained in a well formed in a tray contained within the enclosure. The fluid is a low vapor pressure oil, chemically inert and oxidation resistant. The use of a fluid as the sealing component provides a seal that is self-healing and mechanically robust not subject to normal mechanical wear, breakage, and formation of cracks or pinholes and decouples external mechanical vibrations from internal structural members.

Klebanoff, Leonard E. (Dublin, CA)

2001-01-01T23:59:59.000Z

244

Stacking and twin faults in close-packed crystal structures: exact description of random faulting statistics for the full range of faulting probabilities  

Science Journals Connector (OSTI)

A model of independent random faulting in face-centered-cubic and hexagonal close packing considering single deformation faults or twin faulting is revisited. The approach allows the analysis, within the random model, of the whole range of faulting probabilities. Several descriptions of the underlying faulting process are presented which allows the derivation of different properties of the faulted sequences. The probability of finding two layers of the same type layers apart is derived. It is shown that previous generalizations did not account for mixed terms in the final probability expressions.

Estevez-Rams, E.

2008-08-14T23:59:59.000Z

245

The distribution of biogenic thiols in surface waters of Galveston Bay  

Science Journals Connector (OSTI)

along a salinity gradient in estuarine waters off of Galveston Bay, Texas. ... A major thiol peak was present in Lower Galveston Bay and a minor peak in Upper.

1910-00-90T23:59:59.000Z

246

Trace metal contamination of waters, sediments, and organisms of the Swan Lake area of Galveston Bay.  

E-Print Network [OSTI]

??Swan Lake is a sub-bay of the Galveston Bay system. The area received runoff from a tin smelter via the Wah Chang Ditch which ran… (more)

Park, Junesoo

2012-01-01T23:59:59.000Z

247

Observations and modeling of shallow fault creep along the San Andreas Fault System  

E-Print Network [OSTI]

refraction survey of the Imperial Valley region, California,earthquake, in The Imperial Valley, California, EarthquakeSlip on faults in the Imperial Valley triggered by the 4

Wei, Meng

2011-01-01T23:59:59.000Z

248

Injection Technologies for Fault Attacks on Microprocessors  

Science Journals Connector (OSTI)

The fault injection technique we will analyze in detail in Sect. 16.3, is the constant under-powering of a computing device. By running the chip with a depleted power supply, the attacker is able to insert transi...

Alessandro Barenghi; Guido M. Bertoni; Luca Breveglieri…

2012-01-01T23:59:59.000Z

249

Supporting fault-tolerant communication in networks  

E-Print Network [OSTI]

We address two problems dealing with fault-tolerant communication in networks. The first one is designing a distributed storage protocol tolerant to Byzantine failure of servers. The protocol implements a multi-writer multi-reader register which...

Kanjani, Khushboo

2009-05-15T23:59:59.000Z

250

Automated Fault Location In Smart Distribution Systems  

E-Print Network [OSTI]

measured at the power substation during a single phase to ground fault clearance [17] .............................................. 111 Figure 26 Analyzed signal using wavelet transform from phase B current during a fault [17..., but are not limited to, substation and feeder relay, intelligent controllers for capacitor bank switches or reclosers, Automatic Meter Reading (AMR) systems installed at the customer sites, power quality meters installed at strategic locations in the system, low...

Lotfifard, Saeed

2012-10-19T23:59:59.000Z

251

CALIFORNIA STATE UNIVERSITY, EAST BAY FACULTY EMPLOYMENT OPPORTUNITY  

E-Print Network [OSTI]

CALIFORNIA STATE UNIVERSITY, EAST BAY FACULTY EMPLOYMENT OPPORTUNITY DEPARTMENT OF STATISTICS, statistics and biostatistics, as well as for employment opportunities nationwide. Our programs are flexible about CSU, East Bay visit http://www20.csueastbay.edu. THE DEPARTMENT: The Department of Statistics

Jornsten, Rebecka

252

Dissolved organic matter in Chesapeake Bay sediment pore waters  

E-Print Network [OSTI]

Dissolved organic matter in Chesapeake Bay sediment pore waters David J. Burdige * Department of recent studies of dissolved organic matter (DOM) in Chesapeake Bay sediment pore waters are summar- ized water DOM. This analysis shows that much of the DOM accumulating in sediment pore waters appears

Burdige, David

253

Regulatory effectiveness study for the Christmas Bay Coastal Preserve  

SciTech Connect (OSTI)

The report contains a description and evaluation of essential regulatory activities governing Armand Bayou and its watershed. The report will be used in management planning for the preserve, and will also contribute to the baseline regulatory data for developing the Galveston Bay Comprehensive Conservation and Management Plan. A companion report was prepared for the Christmas Bay Coastal Preserve.

Mitchell, G.; Windsor, D.

1991-12-01T23:59:59.000Z

254

MFR PAPER 1074 Effects of Prudhoe Bay Crude Oil on  

E-Print Network [OSTI]

MFR PAPER 1074 Effects of Prudhoe Bay Crude Oil on Molting Tanner Crabs, Chionoecetes bairdi JOHN F bairdi , from Alaska walers were exposed 10 Prudhoe Bay crude oil in sIalic bioassays ill Ih e laboralory. Crabs in bOlh slages were similarly susceplible 10 crude oil; Ihe eSlimaled 48-hour TLIIl (Illedian

255

Chesapeake Bay Preservation Programs (Multiple States) | Department of  

Broader source: Energy.gov (indexed) [DOE]

Chesapeake Bay Preservation Programs (Multiple States) Chesapeake Bay Preservation Programs (Multiple States) Chesapeake Bay Preservation Programs (Multiple States) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Maryland Program Type Siting and Permitting Provider Chesapeake Bay Program The Chesapeake Bay Program is a unique regional partnership that has led

256

Clean Cities: East Bay Clean Cities (Oakland) coalition  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Bay Clean Cities (Oakland) Coalition Bay Clean Cities (Oakland) Coalition The East Bay Clean Cities (Oakland) coalition works with vehicle fleets, fuel providers, community leaders, and other stakeholders to reduce petroleum use in transportation. East Bay Clean Cities (Oakland) coalition Contact Information Richard Battersby 530-752-9666 rebattersby@ucdavis.edu Chris Ferrara 925-459-8062 caf3@pge.com Coalition Website Clean Cities Coordinators Coord Richard Battersby Coord Coord Chris Ferrara Coord Photo of Richard Battersby Richard Battersby is director of fleet services at the University of California, Davis and has been Coordinator of the East Bay (Oakland) Clean Cities coalition since 2003. Battersby has over 25 years of experience in the fleet industry and has written and participated in numerous local, state, and federal grant-funded

257

E-Print Network 3.0 - automatic fault management Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2000 Tutorial on Summary: Management 5. Fault Tolerant Applications 6. Fault Tolerant Hello Server Example 12;Tutorial on Fault... Systems, Inc, 2000 Who Has Control? ...

258

Western Renewable Energy Zones (Presentation)  

SciTech Connect (OSTI)

This presentation summarizes recent developments and trends pertaining to competitive renewable energy zones, transmission planning and the integration of renewable generation resources.

Hein, J.

2011-06-01T23:59:59.000Z

259

Fuel conditioning facility zone-to-zone transfer administrative controls.  

SciTech Connect (OSTI)

The administrative controls associated with transferring containers from one criticality hazard control zone to another in the Argonne National Laboratory (ANL) Fuel Conditioning Facility (FCF) are described. FCF, located at the ANL-West site near Idaho Falls, Idaho, is used to remotely process spent sodium bonded metallic fuel for disposition. The process involves nearly forty widely varying material forms and types, over fifty specific use container types, and over thirty distinct zones where work activities occur. During 1999, over five thousand transfers from one zone to another were conducted. Limits are placed on mass, material form and type, and container types for each zone. Ml material and containers are tracked using the Mass Tracking System (MTG). The MTG uses an Oracle database and numerous applications to manage the database. The database stores information specific to the process, including material composition and mass, container identification number and mass, transfer history, and the operators involved in each transfer. The process is controlled using written procedures which specify the zone, containers, and material involved in a task. Transferring a container from one zone to another is called a zone-to-zone transfer (ZZT). ZZTs consist of four distinct phases, select, request, identify, and completion.

Pope, C. L.

2000-06-21T23:59:59.000Z

260

Measuring and Modeling Fault Density for Plume-Fault Encounter Probability Estimation  

SciTech Connect (OSTI)

Emission of carbon dioxide from fossil-fueled power generation stations contributes to global climate change. Storage of this carbon dioxide within the pores of geologic strata (geologic carbon storage) is one approach to mitigating the climate change that would otherwise occur. The large storage volume needed for this mitigation requires injection into brine-filled pore space in reservoir strata overlain by cap rocks. One of the main concerns of storage in such rocks is leakage via faults. In the early stages of site selection, site-specific fault coverages are often not available. This necessitates a method for using available fault data to develop an estimate of the likelihood of injected carbon dioxide encountering and migrating up a fault, primarily due to buoyancy. Fault population statistics provide one of the main inputs to calculate the encounter probability. Previous fault population statistics work is shown to be applicable to areal fault density statistics. This result is applied to a case study in the southern portion of the San Joaquin Basin with the result that the probability of a carbon dioxide plume from a previously planned injection had a 3% chance of encountering a fully seal offsetting fault.

Jordan, P.D.; Oldenburg, C.M.; Nicot, J.-P.

2011-05-15T23:59:59.000Z

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

"giant faults" does not lead to total failure, because the displacement equivalent to the fault  

E-Print Network [OSTI]

"giant faults" does not lead to total failure, because the displacement equivalent to the fault changes in physical properties by cold working seen in Fig. 1 are attributed to this accumulated nanoscale as supporting material on Science Online. 5. T. W. Duerig, A. R. Pelton, in Materials Properties Handbook

Rubloff, Gary W.

262

ACTIVE FAULTING AND QUATERNARY SLIP RATES OF THE COLOMBIAN SUB-ANDES  

E-Print Network [OSTI]

at the northern, central and southern segments, with an inferred flat?slab geometry for the Nazca plate (Gutscher et al., 2000). The absence of seismicity 8 above the subducted Carnegie ridge and Mendaña Fault zone, combined with the absence of volcanism (Figures 1a and 2) is... Peruvian Andes display similar deformation styles, mirrored across latitude ~5?S. Although a wide variety of factors such as rheology and mantle dynamics exert control on deformation (e.g. Isacks, 1988), which were not taken into account in this...

Veloza Fajardo, Gabriel Eduardo

2012-12-31T23:59:59.000Z

263

Lower Flathead System Fisheries Study, South Bay of Flathead Lake, Volume III, 1983-1987 Final Report.  

SciTech Connect (OSTI)

The Lower Flathead System Fisheries Study assessed the effects of Kerr Dam operation on the fisheries of the lower Flathead ecosystem. South Bay, the southern most lobe of Flathead Lake, is the most extensive area of shallow water, and therefore, most effected by changes in lake levels. This study began in January of 1984 and was completed in early 1987. Vegetative and structural cover are relatively limited in South Bay, a condition which could contribute to lower recruitment for some fish species. Our data show that the study area contained 0.04% structural and 5.4% vegetative cover in June at full pool. Both figures are less than 1.0% at minimum pool. Structural complexity mediates the ecological interactions between littoral zone fish and their prey, and can affect local productivity and growth in fish. Structural complexity may also be important to overwinter survival of young perch in Flathead Lake. Winter conditions, including ice cover and fall drawdown, seasonally eliminate the vegetative portion of most rooted macrophytes in South Bay. This results in substantial loss of what little structural cover exists, depriving the perch population of habitat which has been occupied all summer. The loss of cover from draw-down concentrates and probably exposes perch to greater predation, including cannibalism, than would occur if structural complexity were greater. 33 refs., 10 figs., 5 tabs.

Cross, David; Waite, Ian

1988-06-01T23:59:59.000Z

264

The San Francisco/Oakland Bay Bridge Will be Partially Closed Presidents' Day Weekend 2012  

E-Print Network [OSTI]

/or alternate bridges: Golden Gate, Richmond-San Rafael, San Mateo-Hayward, Dumbarton BART (BAY AREA RAPIDThe San Francisco/Oakland Bay Bridge Will be Partially Closed Presidents' Day Weekend 2012 In order to complete an essential step in the construction of the new Bay Bridge, the WESTBOUND DECK of the Bay Bridge

Hellerstein, Joseph M.

265

Chesapeake Bay Program Water Quality Database | Data.gov  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Chesapeake Bay Program Water Quality Database Chesapeake Bay Program Water Quality Database Ocean Data Tools Technical Guide Map Gallery Regional Planning Feedback Ocean You are here Data.gov » Communities » Ocean » Data Chesapeake Bay Program Water Quality Database Dataset Summary Description The Chesapeake Information Management System (CIMS), designed in 1996, is an integrated, accessible information management system for the Chesapeake Bay Region. CIMS is an organized, distributed library of information and software tools designed to increase basin-wide public access to Chesapeake Bay information. The information delivered by CIMS includes technical and public information, educational material, environmental indicators, policy documents, and scientific data. Through the use of relational databases, web-based programming, and web-based GIS a large number of Internet resources have been established. These resources include multiple distributed on-line databases, on-demand graphing and mapping of environmental data, and geographic searching tools for environmental information. Baseline monitoring data, summarized data and environmental indicators that document ecosystem status and trends, confirm linkages between water quality, habitat quality and abundance, and the distribution and integrity of biological populations are also available. One of the major features of the CIMS network is the Chesapeake Bay Program's Data Hub, providing users access to a suite of long- term water quality and living resources databases. Chesapeake Bay mainstem and tidal tributary water quality, benthic macroinvertebrates, toxics, plankton, and fluorescence data can be obtained for a network of over 800 monitoring stations.

266

Shoreline survey for unpermitted discharges to Galveston Bay  

SciTech Connect (OSTI)

The objectives of the study are to identify and map unpermitted point source discharges within selected shoreline segments of Galveston Bay and to develop a standard methodology and framework for future comprehensive shoreline surveys of the Galveston Bay system. The pilot study utilized low altitude aerial surveys and shallow draft small boat surveys to determine the extent of and to document locations of unpermitted discharges along 159 miles of bayou and bay shoreline. Nine different shoreline types were surveyed. Positions of discharges, both permitted and unpermitted were logged on to a personal computer data base management system and photographic documentation of both aerial and surface observations were catalogued.

Fay, R.R.; Sweet, S.; Wilson, R.J.

1991-08-01T23:59:59.000Z

267

Frictional characteristics of serpentinite from the Motagua fault zone in Guatemala: an experimental study  

E-Print Network [OSTI]

In order to uncierstand the sliding behavior of serpent, inite it is necessary to irieniify the physical processes Nhich are op ra tive at the rock-retch interface. Accordingly, the deformation features produced during stable and stick-slip sliding... are in the vicinity of the host- rock interfaces. At these interfac:s there is also a noticeable reduc- tion in ti'. e grain siiz?, relative to che central portion' of the Figure 14. Photomicrographs showing cross-sectional view of stable sliding (mesh) surfaces...

Dengo, Carlos Arturo

2012-06-07T23:59:59.000Z

268

Isotropic Events Observed with a Borehole Array in the Chelungpu Fault Zone, Taiwan  

Science Journals Connector (OSTI)

...finite-difference simulation [fig. S3...tensors. The modeling shows that the...source in the modeling. The observed...and BHS4. Our modeling suggests that the...injection layer. The rapid attenuation...Roth M. , Automated seismic event...ground motion simulation of the 1999...

Kuo-Fong Ma; Yen-Yu Lin; Shiann-Jong Lee; Jim Mori; Emily E. Brodsky

2012-07-27T23:59:59.000Z

269

Isotropic Events Observed with a Borehole Array in the Chelungpu Fault Zone, Taiwan  

Science Journals Connector (OSTI)

...velocities, density, porosity, and permeability measured at a deep...for hydrocarbon reservoirs . Comput. Geosci...Stress-dependence of the permeability and porosity of sandstone and...Hole-A . Int. J. Rock Mech. Mining Sci...

Kuo-Fong Ma; Yen-Yu Lin; Shiann-Jong Lee; Jim Mori; Emily E. Brodsky

2012-07-27T23:59:59.000Z

270

FEDMAP FY 2011 Projects 3D/4D Mapping of the San Andreas Fault Zone (Graymer)  

E-Print Network [OSTI]

of surface and groundwater sustainability, land-use planning, ecosystem health, climate change, and sea level Basin and Range Province. Location: Nevada Strategic Direction: Energy and Minerals, Natural Hazards: Colorado, New Mexico Website: http://crustal.cr.usgs.gov/projects/rgb Strategic Direction: Water Issues

271

Geomechanical effects on CO2 leakage through fault zones during large-scale underground injection  

E-Print Network [OSTI]

induced seismicity during hydraulic fracturing of Shale-Gasfault reactivation and hydraulic fracturing during shale gas

Rinaldi, A.P.

2014-01-01T23:59:59.000Z

272

Geomechanical effects on CO2 leakage through fault zones during large-scale underground injection  

E-Print Network [OSTI]

hydraulic fracturing of Shale-Gas reservoir. J. Petrol. Sci.hydraulic fracturing during shale gas operations (Rutqvist

Rinaldi, A.P.

2014-01-01T23:59:59.000Z

273

Indication of high pore-fluid pressures in a seismically-active fault zone  

Science Journals Connector (OSTI)

......changes in a CO2 injection process in a fractured reservoir, 70th Ann. Int. SEG Mtg., Calgary, Expanded Abstracts...Geophysics, 70th Ann. Int. SEG Mtg., Calgary, Expanded Abstracts...Earthquakes: Understanding Crustal Processes Leading to Destructive Earthquakes......

Crampin Stuart; Theodora Volti; Sebastien Chastin; Agust Gudmundsson; Ragnar Stefánsson

2002-11-01T23:59:59.000Z

274

Relation between deformation and seismicity in the active fault zone of Kamchatka, Russia  

Science Journals Connector (OSTI)

......1993. Earthquake energy and tectonic stress...investigation for searching geothermal water in southeast part of Petropavlovsk' geothermal area in 1988-90 and...accumulated potential energy, i.e. seismicity...work is prohibited by cost. Frequent measurements......

V.A. Churikov; Yu. O. Kuzmin

1998-06-01T23:59:59.000Z

275

Mechanics of grain-size reduction in fault zones Charles G. Sammis1  

E-Print Network [OSTI]

timescale significantly smaller particles at any strain rate. However, shock loading and subcritical crack growth can produce nanometer-scale fragments in compression. Under tensile loading the fragment size is determined by a competition between the nucleation of cracks and stress relaxation in their neighborhoods

Ben-Zion, Yehuda

276

Late Tertiary paleomagnetic data from Leyte, Philippines: implications for Philippine fault zone motion  

E-Print Network [OSTI]

= 20. 1' (oss ? 6. 6', le ? 29. 9) and a paleomagnetic pole A ? 89. 0" N, P ? 10. 4'E (Ass ? 4. 8', K ? 55. 3). Eight early Neogene sites (3 normal polarity and 5 reversed polarity) give a mean direction D = 23. 2', I = 13. 9' (oss ? 9. 3', k = 36.... 2) and a paleomagnetic pole A = 66. 5'N, 6 = 220. 5'E (Ass ? 7. 1', It = 62. 0). The late Veogene pole is indistinguishable at the 95% confidence level from published Plio-Pleistocene poles from the entire Philippines and the late Miocene pole...

Cole, Jay Timothy

1988-01-01T23:59:59.000Z

277

TEC Rail TG Summary_Green Bay  

Broader source: Energy.gov (indexed) [DOE]

September 13-14, 2006 September 13-14, 2006 Green Bay, WI RAIL TOPIC GROUP Mr. Jay Jones began the meeting with a welcome and introduction of the topic members, other participants, and support staff. A brief overview was given of the topic group's activities since the last TEC meeting. This meeting focused on the Topic Group's subgroup activities. Key comments and discussions are summarized below. Status Update of the Rail Topic Group Mr. Jones mentioned the planned creation of a new topic group to be called the Routing Topic Group. The Rail Topic Group would still exist as a topic group. However, since the emphasis would be in developing routing criteria and ultimately a national suite of routes over the next year or so, this separate Routing Topic Group would be created to address

278

Massachusetts Bay Trans Auth | Open Energy Information  

Open Energy Info (EERE)

Auth Auth Jump to: navigation, search Name Massachusetts Bay Trans Auth Place Massachusetts Utility Id 49848 Utility Location Yes Ownership P NERC Location NPCC NERC NPCC Yes Operates Generating Plant Yes Activity Generation Yes Activity Wholesale Marketing Yes Activity Retail Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates Commercial: $0.0896/kWh Transportation: $0.1250/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from

279

Geometry of Cenozoic extensional faulting: Dixie Valley, Nevada | Open  

Open Energy Info (EERE)

Geometry of Cenozoic extensional faulting: Dixie Valley, Nevada Geometry of Cenozoic extensional faulting: Dixie Valley, Nevada Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Geometry of Cenozoic extensional faulting: Dixie Valley, Nevada Abstract Precise definition of geometric relationships between individual basins and ranges may help to reveal the mechanical processes of Basin and Range Cenozoic extensional faulting at depth. Previous studies have attempted to identify simple horsts and grabens, tilted crustal blocks with planar faulting, or tilted crustal blocks with listric faulting in the shallow crust. Normal faults defining these crustal blocks may root (1) individually in the ductile lower crust, (2) in regional or local low-angle detachment faults, or (3) in igneous intrusions or decoupling surfaces

280

Robust model-based fault diagnosis for chemical process systems  

E-Print Network [OSTI]

diagnosis systems, which use limited information about the process model to robustly detect, discriminate, and reconstruct instrumentation faults. Broadly, the proposed method consists of a novel nonlinear state and parameter estimator coupled with a fault...

Rajaraman, Srinivasan

2006-08-16T23:59:59.000Z

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

New approach to the fault location problem using synchronized sampling  

E-Print Network [OSTI]

This thesis presents a new approach to solving the problem of fault location on a transmission line using synchronized data from both ends of the line. The synchronized phase voltage and current samples taken during the fault transient are used...

Mrkic, Jasna

2012-06-07T23:59:59.000Z

282

A hybrid fault tolerance technique in grid computing system  

Science Journals Connector (OSTI)

In order to achieve high level of reliability and availability, the grid infrastructure should be a foolproof fault tolerant. Fault tolerance plays a key role in order to assert availability and reliability of...

Kalim Qureshi; Fiaz Gul Khan; Paul Manuel; Babar Nazir

2011-04-01T23:59:59.000Z

283

Scalable, Fault-tolerant Management in a Service Oriented Architecture  

E-Print Network [OSTI]

Scalable, Fault-tolerant Management in a Service Oriented Architecture Harshawardhan Gadgil: Scalable, Fault-tolerance, Service Oriented Management, Architecture 1. Introduction With the explosion. The service-oriented architecture provides a simple and flexible framework for building sophisticated

284

Dynamic Inductance in Saturated Cores Fault Current Limiters  

Science Journals Connector (OSTI)

The saturated cores Fault Current Limiter (FCL) is one of the leading ... for providing a commercial robust solution to the fault current problem. Basically, the saturated cores FCL ... its saturated cores state ...

Y. Nikulshin; Y. Wolfus; A. Friedman…

2014-09-01T23:59:59.000Z

285

Modeling and Simulation of Resistive Superconducting Fault-Current Limiters  

Science Journals Connector (OSTI)

Superconducting fault-current limiters (SFCL) offer ideal performance in electrical ... simulation model for a novel resistive type superconducting fault-current limiter is proposed. This model includes the elect...

S. Nemdili; S. Belkhiat

2012-10-01T23:59:59.000Z

286

A Magnetic Shielding Type Superconducting Fault-Current Limiter  

Science Journals Connector (OSTI)

In a Magnetic Shielding type Fault-Current Limiter (MSFCL), the characteristics of the magnetic ... ) is an important factor in limiting the current flow. In this study, to improve the efficiency of the fault current

N. Miyauchi; H. Nakane; S. Haseyama; S. Yoshizawa

1999-01-01T23:59:59.000Z

287

Consequences of Fault Currents Contributed by Distributed Generation  

E-Print Network [OSTI]

Consequences of Fault Currents Contributed by Distributed Generation Intermediate Project Report Currents Contributed by Distributed Generation Intermediate Report for the Project "New Implications in systems with distributed generation. The main concept described is that fault current throughout power

288

IVF: characterizing the vulnerability of microprocessor structures to intermittent faults  

Science Journals Connector (OSTI)

With the advancement of CMOS manufacturing process to nano-scale, future shipped microprocessors will be increasingly vulnerable to intermittent faults. Quantitatively characterizing the vulnerability of microprocessor structures to intermittent faults ...

Songjun Pan; Yu Hu; Xiaowei Li

2010-03-01T23:59:59.000Z

289

Design and analysis of a fault tolerant network processor  

E-Print Network [OSTI]

This thesis investigates the effect of transient faults on a processor and proposes on-chip fault tolerant design techniques to improve its reliability. The target processor is a general 32-bit, four stage pipeline, dual context RISC style design...

Desai, Shaishav A

2012-06-07T23:59:59.000Z

290

Dining philosophers with masking tolerance to crash faults  

E-Print Network [OSTI]

We examine the tolerance of dining philosopher algorithms subject to process crash faults in arbitrary conflict graphs. This classic problem is unsolvable in asynchronous message-passing systems subject to even a single crash fault. By contrast...

Idimadakala, Vijaya K.

2009-05-15T23:59:59.000Z

291

Bay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit, Annapolis, Maryland (Fact Sheet), Building America Case Study: Efficient Solutions for New and Existing Homes, Building Technologies Office (BTO)  

Broader source: Energy.gov (indexed) [DOE]

Bay Ridge Gardens-Mixed Bay Ridge Gardens-Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit Annapolis, Maryland PROJECT INFORMATION Construction: Existing Type: Apartment building: Bay Ridge Gardens Annapolis, MD www.bayridgegardens.com Size: 12 apartment units, 713 ft 2 and 909 ft 2 each Year of construction: 1970s Date completed: 2013 Climate Zone: Mixed-humid PERFORMANCE DATA Pre-retrofit annual energy use (normalized): 28.4 kilowatt-hour per square foot (kWh/ft 2 ) Post-retrofit annual energy use (normalized): 16.3 kWh/ft 2 Percent energy savings: 43% Incremental cost of energy efficiency measures: $85,996 Monetized annual energy savings: $6,900 Savings to Investment Ratio: 1.1 Significant energy savings-43% in this case-are possible in older multifamily

292

Photovoltaic ground fault and blind spot electrical simulations.  

SciTech Connect (OSTI)

Ground faults in photovoltaic (PV) systems pose a fire and shock hazard. To mitigate these risks, AC-isolated, DC grounded PV systems in the United States use Ground Fault Protection Devices (GFPDs), e.g., fuses, to de-energize the PV system when there is a ground fault. Recently the effectiveness of these protection devices has come under question because multiple fires have started when ground faults went undetected. In order to understand the limitations of fuse-based ground fault protection in PV systems, analytical and numerical simulations of different ground faults were performed. The numerical simulations were conducted with Simulation Program with Integrated Circuit Emphasis (SPICE) using a circuit model of the PV system which included the modules, wiring, switchgear, grounded or ungrounded components, and the inverter. The derivation of the SPICE model and the results of parametric fault current studies are provided with varying array topologies, fuse sizes, and fault impedances. Closed-form analytical approximations for GFPD currents from faults to the grounded current carrying conductor-known as %E2%80%9Cblind spot%E2%80%9D ground faults-are derived to provide greater understanding of the influence of array impedances on fault currents. The behavior of the array during various ground faults is studied for a range of ground fault fuse sizes to determine if reducing the size of the fuse improves ground fault detection sensitivity. The results of the simulations show that reducing the amperage rating of the protective fuse does increase fault current detection sensitivity without increasing the likelihood of nuisance trips to a degree. Unfortunately, this benefit reaches a limit as fuses become smaller and their internal resistance increases to the point of becoming a major element in the fault current circuit.

Flicker, Jack David; Johnson, Jay

2013-06-01T23:59:59.000Z

293

Detachment Faulting & Geothermal Resources- Pearl Hot Spring, NV  

Broader source: Energy.gov [DOE]

Detachment Faulting & Geothermal Resources - Pearl Hot Spring, NV presentation at the April 2013 peer review meeting held in Denver, Colorado.

294

A method for quantitative fault diagnosability analysis of stochastic linear descriptor models  

Science Journals Connector (OSTI)

Analyzing fault diagnosability performance for a given model, before developing a diagnosis algorithm, can be used to answer questions like ''How difficult is it to detect a fault f"i?'' or ''How difficult is it to isolate a fault f"i from a fault f"j?''. ... Keywords: Fault detection and isolation, Fault diagnosability analysis, Model-based diagnosis

Daniel Eriksson; Erik Frisk; Mattias Krysander

2013-06-01T23:59:59.000Z

295

Bridge Fault Simulation Strategies for CMOS Integrated Circuits Brian Chess  

E-Print Network [OSTI]

Bridge Fault Simulation Strategies for CMOS Integrated Circuits Brian Chess Tracy Larrabee \\Lambda the Primitive Bridge Function, a char­ acteristic function describing the behavior of bridged com­ ponents, we present a theorem for detecting feedback bridge faults. We discuss two different methods of bridge fault

Larrabee, Tracy

296

UNSUPERVISED CLUSTERING FOR FAULT DIAGNOSIS IN NUCLEAR POWER PLANT COMPONENTS  

E-Print Network [OSTI]

1 UNSUPERVISED CLUSTERING FOR FAULT DIAGNOSIS IN NUCLEAR POWER PLANT COMPONENTS Piero Baraldi1 on transients originated by different faults in the pressurizer of a nuclear power reactor. Key Words: Fault of Nuclear Power Plants (NPPs) [Cheon et al., 1993; Kim et al., 1996; Reifman, 1997; Zio et al., 2006a; Zio

Boyer, Edmond

297

Stacking fault energy and microstructure effects on torsion texture evolution  

Science Journals Connector (OSTI)

...research-article Stacking fault energy and microstructure effects...2000, , Rosario, Argentina 3 Department of Geology...The stacking fault energy (SFE) of the metal...torsion| Stacking fault energy and microstructure e...CONICET-UNR) 2000, Rosario, Argentina 3Department of Geology...

2000-01-01T23:59:59.000Z

298

COMPLETE FAULT ANALYSIS FOR LONG TRANSMISSION LINE USING  

E-Print Network [OSTI]

COMPLETE FAULT ANALYSIS FOR LONG TRANSMISSION LINE USING SYNCHRONIZED SAMPLING Nan Zhang Mladen 77843-3128, U.S.A. Abstract: A complete fault analysis scheme for long transmission line represented fault analysis tool for transmission lines is very useful for on-line confirmation and off-line trouble

299

Pedro Bay Village Council (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Pedro Bay Village Council (Utility Company) Pedro Bay Village Council (Utility Company) Jump to: navigation, search Name Pedro Bay Village Council Place Alaska Utility Id 14633 Utility Location Yes Ownership M NERC Location AK Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Service Residential School Commercial Average Rates Residential: $0.9080/kWh Commercial: $0.8510/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Pedro_Bay_Village_Council_(Utility_Company)&oldid=411345

300

City of Larsen Bay, Alaska (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Larsen Bay, Alaska (Utility Company) Larsen Bay, Alaska (Utility Company) Jump to: navigation, search Name City of Larsen Bay Place Alaska Utility Id 10716 Utility Location Yes Ownership M NERC Location AK Operates Generating Plant Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Rate Commercial Industrial Rate Industrial Residential Rate Residential Average Rates Residential: $0.3910/kWh Commercial: $0.3340/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=City_of_Larsen_Bay,_Alaska_(Utility_Company)&oldid=40983

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

East Bay Municipal Util Dist | Open Energy Information  

Open Energy Info (EERE)

Bay Municipal Util Dist Bay Municipal Util Dist Jump to: navigation, search Name East Bay Municipal Util Dist Place California Utility Id 5571 Utility Location Yes Ownership M NERC Location WECC NERC WECC Yes Operates Generating Plant Yes Activity Generation Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=East_Bay_Municipal_Util_Dist&oldid=41061

302

Wave-forced resuspension of upper Chesapeake Bay muds  

Science Journals Connector (OSTI)

Moored instruments were used to make observations of near bottom currents, waves, temperature, salinity, and turbidity at shallow (3.5 m and 5.5 m depth) dredged sediment disposal sites in upper Chesapeake Bay du...

Lawrence P. Sanford

1994-03-01T23:59:59.000Z

303

Seagrass habitat utilization by fishes in Christmas Bay, Texas  

E-Print Network [OSTI]

Fishes in Christmas Bay, TX were collected during April 1994 through March 1995 to: 1) assess temporal variability in their density, biomass, and diversity; 2) define the relationship between variability in fish population parameters...

Crotwell, Patricia Lynn

2012-06-07T23:59:59.000Z

304

Sediment Toxicity Identification Evaluations San Francisco Bay Regional Monitoring  

E-Print Network [OSTI]

Sediment Toxicity Identification Evaluations San Francisco Bay Regional Monitoring Program chemicals of concern that may impact the estuary's ecosystem. Toxicity Identification Evaluation (TIE identified weak associations between mortality and bulk-phase chlordane and silver concentrations at Redwood

305

Benthic exchange of nutrients in Galveston Bay, Texas  

Science Journals Connector (OSTI)

Nutrient regeneration rates were determined at three sites increasing in distance from the Trinity River, the main freshwater input source, to Galveston Bay, Texas, from 1994 through 1996. Diffusive fluxes ... be...

Kent W. Warnken; Gary A. Gill; Peter H. Santschi; Lawrence L. Griffin

2000-10-01T23:59:59.000Z

306

Rose-bay Willow-Herb and Honey Bees  

Science Journals Connector (OSTI)

... and even store surplus nectar from the rose-bay willow-herb. This plant also provides humble bees with food at a time when the next year's queens are being reared ...

1945-04-21T23:59:59.000Z

307

Aerial survey of Bay Area continues through Saturday | National Nuclear  

National Nuclear Security Administration (NNSA)

of Bay Area continues through Saturday | National Nuclear of Bay Area continues through Saturday | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Aerial survey of Bay Area continues through Saturday Aerial survey of Bay Area continues through Saturday Posted By Office of Public Affairs NNSA Blog This week, a NNSA helicopter has been flying at a low-level altitude over

308

McKay Bay Facility Biomass Facility | Open Energy Information  

Open Energy Info (EERE)

McKay Bay Facility Biomass Facility McKay Bay Facility Biomass Facility Jump to: navigation, search Name McKay Bay Facility Biomass Facility Facility McKay Bay Facility Sector Biomass Facility Type Municipal Solid Waste Location Hillsborough County, Florida Coordinates 27.9903597°, -82.3017728° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":27.9903597,"lon":-82.3017728,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

309

Climate Zones | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Residential Buildings » Building America » Climate Zones Residential Buildings » Building America » Climate Zones Climate Zones Building America determines building practices based on climate zones to achieve the most energy savings in a home. This page offers some general guidelines on the definitions of the various climate regions based on heating degree-days, average temperatures, and precipitation. You can also view the Guide to Determining Climate Regions by County. Hot-Humid A hot-humid climate is generally defined as a region that receives more than 20 in. (50 cm) of annual precipitation and where one or both of the following occur: A 67°F (19.5°C) or higher wet bulb temperature for 3,000 or more hours during the warmest 6 consecutive months of the year; or A 73°F (23°C) or higher wet bulb temperature for 1,500 or more

310

The problem of vertical zoning  

Science Journals Connector (OSTI)

...deposits, genesis sheet silicates silicates talc United States Vermont Vertical zoning GeoRef, Copyright 2012, American Geosciences...levelgivingasmuchas29ouncesofgold per ton." Similar descriptionsof the Yankee Girl and other minesin the districtconvincinglydemonstrateverticalchangesin...

Charles Frederick Park

311

Unsaturated Zone Hydrology Jasper Vrugt  

E-Print Network [OSTI]

CEE 271 Unsaturated Zone Hydrology Instructor Jasper Vrugt Engineering Tower #834E / #536 (LAB) Tel.: 505-231-2698 jasper @uci.edu Office Hours: By Appointment Lecture, 1 hour; discussion, 20 minutes: ICS

Vrugt, Jasper A.

312

Structure of the eastern Red Rocks and Wind Ridge thrust faults, Wyoming: how a thrust fault gains displacement along strike  

E-Print Network [OSTI]

STRUCTURE OF THE EASTERN RED ROCKS AND WIND RIDGE THRUST FAULTS, WYOMING: HOW A THRUST FAULT GAINS DISPLACEMENT ALONG STRIKE A Thesis by BRENT STANLEY HUNTSMAN Submitted to the Graduate College of Texas A&M University in partial fulfillment... of the requirements for the degree of MASTER OF SCIENCE December 1983 Major Subject: Geology STRUCTURE OF THE EASTERN RED ROCKS AND WIND RIDGE THRUST FAULTS, WYOMING: HOW A THRUST FAULT GAINS DISPLACEMENT ALONG STRIKE A Thesis by BRENT STANLEY HUNTSMAN...

Huntsman, Brent Stanley

1983-01-01T23:59:59.000Z

313

Petroleum hydrocarbon-degrading bacteria in the Galveston Bay system  

E-Print Network [OSTI]

PETROLEUM HYDRQCARBOiV-DEGRADING BACTERIA IN THE GALVESTON BAY SYSTEM A Thesis by STEVEN JAMES SCHROPP Submitted to the Graduate College of Texas ASM University in partial fulfillment of the requirement for the degree of MASTER OF SCIFNCE... December 1979 Major Subject: Biology PETROLEUM HYDROCARBON-DEGRADING BACTERIA IN THE GALVESTON BAY SYSTEM A Thesis by STEVEN JAMES SCHROPP Approved as to style and content by: (Co-Chairman of Committee) '( ~CA. ( -Chairman of Committee) (Head...

Schropp, Steven James

1979-01-01T23:59:59.000Z

314

Commencement Bay Nearshore/Tideflats Remedial Investigation. summary report  

SciTech Connect (OSTI)

The report summarizes work complete under the U.S. EPA/WDOE Cooperative Agreement for the Commencement Bay Nearshore/Tideflats Remedial Investigation of the Waterways/Shoreline area. The Commencement Bay Superfund Investigation includes various integrated program management and technical components. These include assessments of chemical contamination, biological effects, toxicity, and public health concerns; identification of sources; and identification of potential remedial actions and technologies.

Not Available

1985-08-01T23:59:59.000Z

315

Wetlands and Riparian Zones | Open Energy Information  

Open Energy Info (EERE)

and Riparian Zones Jump to: navigation, search Retrieved from "http:en.openei.orgwindex.php?titleWetlandsandRiparianZones&oldid612217" Category: NEPA Resources...

316

Air and rain toxics deposition monitoring in Galveston Bay Texas  

SciTech Connect (OSTI)

In order to fulfill the mandates of the Great Waters Program and portions of the Clean Air Act Amendments of 1990, the Environmental Protection Agency (EPA) has initiated atmospheric monitoring research in important and representative water bodies, including coastal waters, for evidence of atmospheric deposition of pollutants. These pollutants include nutrients, trace metals, polynuclear aromatic hydrocarbons and PCBs. A site was established in Seabrook Texas on the western shore of Galveston Bay representative of southern, coastal water system. This study determines selected environmental pollutants of potential concern to Galveston Bay and other Gulf coastal waters. While information is currently being generated by other investigations in Galveston Bay, such as EPA EMAP, Galveston Bay National Estuary, NOAA Status and Trends and other programs on contaminants in sediments and organisms, little reliable data is available to assess atmospheric deposition. The importance of atmospheric deposition of contaminants to Galveston Bay, based on air and rain samples collected continuously from March 1995 to March 1996 will be presented and compared to the results from other Great Waters Program sites. These results are critical to the understanding of the relative importance of various contaminant inputs to Galveston Bay by estimating atmospheric depositional fluxes.

Wade, T.; Sweet, S.; Park, J.; Cifuentes, L.; Tindale, N.; Santschi, P.; Gill, G. [Texas A and M Univ., College Station, TX (United States). Coll. of Geosciences and Maritime Studies

1995-12-31T23:59:59.000Z

317

Air toxics deposition monitoring in Galveston Bay Texas  

SciTech Connect (OSTI)

In order to fulfill the mandates of the Great Waters Program and portions of the Clean Air Act Amendments of 1990, the Environmental Protection Agency (EPA) has initiated atmospheric monitoring research in important and representative water bodies, including coastal waters, for evidence of atmospheric deposition of pollutants. These pollutants include nutrients, trace metals, polynuclear aromatic hydrocarbons, PCBs and chlorinated pesticides. A site was established in Galveston Bay, Texas as a representative souther, coastal water system. This study determines selected environmental pollutants of potential concern to Galveston Bay and other Gulf coastal waters. While information is currently being generated by other investigations in Galveston Bay, such as EPA EMAP, Galveston Bay National Estuary, NOAA Status and Trends and other programs on contaminants in sediments and organisms, little reliable data is available to assess atmospheric deposition. This study is producing information on atmospheric deposition of pollutants to Galveston Bay, as well as on long range transport of pollutants to other water bodies. These research results are critical to the understanding of the relative importance of pollution inputs to Galveston Bay by estimating atmospheric depositional fluxes. The results from this Program will also be compared with the results from other Great Waters Program sites.

Wade, T.L.; Sweet, S.; Cifuentes, L.; Tindale, N.; Santschi, P.; Gill, G. [Texas A and M Univ., College Station, TX (United States)

1994-12-31T23:59:59.000Z

318

Fault-tolerant search of container codes  

Science Journals Connector (OSTI)

This paper describes a method to locate and recognize container code characters. This method is aimed to make more fault-tolerant a system based on tophat transformation, segmentation algorithms, filters and classifiers. Our aim is to be able to find ... Keywords: character recognition, computer vision, segmentation

Juan Rosell; Gabriela Andreu; Alberto Pérez

2006-08-01T23:59:59.000Z

319

Fault-tolerant search of container codes  

Science Journals Connector (OSTI)

This paper describes a method to locate and recognize container code characters. This method is aimed to make more fault-tolerant a system based on tophat transformation, segmentation algorithms, filters and classifiers. Our aim is to be able to find ... Keywords: character recognition, computer vision, segmentation

Juan Rosell; Gabriela Andreu; Alberto Pérez

2006-09-01T23:59:59.000Z

320

Sensor Fault Diagnosis Using Principal Component Analysis  

E-Print Network [OSTI]

and the assumption of white Gaussian noise, the effect of noise on the isolability is studied, and the minimum magnitude of isolable fault in each sensor is found based on the distribution of noise in the measurement system. Next, for the decision process a...

Sharifi, Mahmoudreza

2010-07-14T23:59:59.000Z

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Adaptive performance support for fault diagnosis  

Science Journals Connector (OSTI)

This paper introduces a strategy, a user model, and a methodology for utilising adaptive hypermedia in performance support domain and specifically for fault diagnosis. This utilisation is implemented by employing task-specific and user-centred hypermedia ... Keywords: adaptive hypermedia, diagnostic expert systems, performance support systems, semantic data modelling, user modelling

Ammar M. Huneiti

2008-07-01T23:59:59.000Z

322

FPGA Interconnect Delay Fault Testing Erik Chmelar  

E-Print Network [OSTI]

A satisfactory FPGA testing method meets several crite- ria. First, the routing resources must be explicitlyFPGA Interconnect Delay Fault Testing Erik Chmelar Center for Reliable Computing Stanford is a scalable manufactur- ing test method for all SRAM-based FPGAs, able to detect multiple interconnect delay

Stanford University

323

Radon emanation on San Andreas Fault  

Science Journals Connector (OSTI)

... RADON is constantly emanated from the Earth into its atmosphere, normally in minute amounts. ... is constantly emanated from the Earth into its atmosphere, normally in minute amounts. Radon emanation is known to be anomalously large on active faults and to show temporal variations ...

Chi-Yu King

1978-02-09T23:59:59.000Z

324

All row, planar fault detection system  

DOE Patents [OSTI]

An apparatus, program product and method for detecting nodal faults may simultaneously cause designated nodes of a cell to communicate with all nodes adjacent to each of the designated nodes. Furthermore, all nodes along the axes of the designated nodes are made to communicate with their adjacent nodes, and the communications are analyzed to determine if a node or connection is faulty.

Archer, Charles Jens; Pinnow, Kurt Walter; Ratterman, Joseph D; Smith, Brian Edward

2013-07-23T23:59:59.000Z

325

Predicted survival of the bay anchovy (Anchoa mitchilli) in the heated effluent of a power plant on Galveston Bay, Texas  

Science Journals Connector (OSTI)

The bay anchovy (Anchoa mitchilli), collected from the intake canal of the P.H. Robinson Generating Station, Bacliff, Texas, were tested for 180 min at various constant temperatures during June 1974 through Septe...

Kyung S. Chung; Kirk Strawn

1982-01-01T23:59:59.000Z

326

Active Fault Segments As Potential Earthquake Sources- Inferences From  

Open Energy Info (EERE)

Active Fault Segments As Potential Earthquake Sources- Inferences From Active Fault Segments As Potential Earthquake Sources- Inferences From Integrated Geophysical Mapping Of The Magadi Fault System, Southern Kenya Rift Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Active Fault Segments As Potential Earthquake Sources- Inferences From Integrated Geophysical Mapping Of The Magadi Fault System, Southern Kenya Rift Details Activities (0) Areas (0) Regions (0) Abstract: Southern Kenya Rift has been known as a region of high geodynamic activity expressed by recent volcanism, geothermal activity and high rate of seismicity. The active faults that host these activities have not been investigated to determine their subsurface geometry, faulting intensity and constituents (fluids, sediments) for proper characterization of tectonic

327

Definition: Enhanced Fault Detection Technology | Open Energy Information  

Open Energy Info (EERE)

Technology Technology Jump to: navigation, search Dictionary.png Enhanced Fault Detection Technology Enhanced fault detection technology enables higher precision and greater discrimination of fault location and type with coordinated measurement among multiple devices. For distribution applications, this technology can detect and isolate faults without full-power re-closing, reducing the frequency of through-fault currents. Using high resolution sensors and fault signatures, this technology can better detect high impedance faults. For transmission applications, this technology will employ high speed communications between multiple elements (e.g., stations) to protect entire regions, rather than just single elements. It can also use the latest digital techniques to advance beyond conventional impedance relaying of

328

Category:ASHRAE Climate Zones | Open Energy Information  

Open Energy Info (EERE)

ASHRAE Climate Zones ASHRAE Climate Zones Jump to: navigation, search Climate Zones defined in the ASHRAE 169-2006 standards. Pages in category "ASHRAE Climate Zones" The following 30 pages are in this category, out of 30 total. C Climate Zone 1A Climate Zone 1B Climate Zone 2A Climate Zone 2B Climate Zone 3A Climate Zone 3B Climate Zone 3C Climate Zone 4A Climate Zone 4B Climate Zone 4C C cont. Climate Zone 5A Climate Zone 5B Climate Zone 5C Climate Zone 6A Climate Zone 6B Climate Zone 7A Climate Zone 7B Climate Zone 8A Climate Zone 8B Climate Zone Number 1 C cont. Climate Zone Number 2 Climate Zone Number 3 Climate Zone Number 4 Climate Zone Number 5 Climate Zone Number 6 Climate Zone Number 7 Climate Zone Number 8 Climate Zone Subtype A Climate Zone Subtype B Climate Zone Subtype C Retrieved from

329

The Cost of the Technological Sublime: Daring Ingenuity and the new San Francisco-Oakland Bay Bridge  

E-Print Network [OSTI]

Cruz. ‘Unity Towers East Bay Bridge‘, New East Span ProposalSubmitted to MTC Bay Bridge Design Task Force, 6 May.Francisco- Oakland Bay Bridge, T.Y. Lin International and

Frick, Karen Trapenberg

2008-01-01T23:59:59.000Z

330

Experimental effects of black brant herbivory and fecal addition on the eelgrass animal community in Humboldt Bay, California, USA  

E-Print Network [OSTI]

HUMBOLDT BAY, CALIFORNIA, USA By Adam J. Frimodig A ThesisHUMBOLDT BAY, CALIFORNIA, USA By Adam J. Frimodig ApprovedHumboldt Bay, California, USA Adam J. Frimodig Seagrass beds

Frimodig, Adam J.

2007-01-01T23:59:59.000Z

331

Innovation and Success in Planning and Zoning  

Broader source: Energy.gov [DOE]

This document summarizes several successful initiatives to implement solar-friendly planes and zoning codes.

332

Area balance and strain in an extensional fault system: Strategies for improved oil recovery in fractured chalk, Gilbertown Field, southwestern Alabama. Final report, March 1996--September 1998  

SciTech Connect (OSTI)

This project was designed to analyze the structure of Mesozoic and Tertiary strata in Gilbertown Field and adjacent areas to suggest ways in which oil recovery can be improved. The Eutaw Formation comprises 7 major flow units and is dominated by low-resistivity, low-contrast play that is difficult to characterize quantitatively. Selma chalk produces strictly from fault-related fractures that were mineralized as warm fluid migrated from deep sources. Resistivity, dipmeter, and fracture identification logs corroborate that deformation is concentrated in the hanging-wall drag zones. New area balancing techniques were developed to characterize growth strata and confirm that strain is concentrated in hanging-wall drag zones. Curvature analysis indicates that the faults contain numerous fault bends that influence fracture distribution. Eutaw oil is produced strictly from footwall uplifts, whereas Selma oil is produced from fault-related fractures. Clay smear and mineralization may be significant trapping mechanisms in the Eutaw Formation. The critical seal for Selma reservoirs, by contrast, is where Tertiary clay in the hanging wall is juxtaposed with poorly fractured Selma chalk in the footwall. Gilbertown Field can be revitalized by infill drilling and recompletion of existing wells. Directional drilling may be a viable technique for recovering untapped oil from Selma chalk. Revitalization is now underway, and the first new production wells since 1985 are being drilled in the western part of the field.

Pashin, J.C.; Raymond, D.E.; Rindsberg, A.K.; Alabi, G.G.; Carroll, R.E.; Groshong, R.H.; Jin, G.

1998-12-01T23:59:59.000Z

333

Novel 3-Phase Inductive Fault Current Limiter  

Science Journals Connector (OSTI)

The paper describes the inductive three-phase fault current limiter. In this work I examine the novel arrangements of the perfect closed superconducting loop made of HTS wire. I applied one iron core with 3 limbs and special loops for uniform temperature of the superconducting wire. In this work I present the results of my experiments with this device. I present the static and dynamic measured results of this solution. It has got several advantages e. g. fast switching and less fault power for high-power electric machines. The advantage of the equipment is that in the case of single-phase short circuit the current will decrease in all the three phases. This can be an appropriate solution for high power machines. For example, in the case of high-power electric motor if there is a single-phase breaking or a single phase short circuit, we can decrease the current in the three phases.

Janos Kosa

2012-01-01T23:59:59.000Z

334

Morphometric and geometric characterization of normal faults on Mars  

Science Journals Connector (OSTI)

Abstract Using three different approaches (fault plane fitting, 3D crater rim palinspatic restorations and fault scarps morphometric analysis) we investigate the geometry and degradation history of Martian normal faults in two distinct areas. The three independent methods produce similar results, indicating that the average dip angle of the normal faults on these two locations is probably below the value that is usually assumed for Mars (?60°). Our best estimate for this average dip angle is 46.8 ± 9.8 ° , which is a value comparable with the mean dip angle inferred on Earth for seismically active normal faults. This lower average dip angle implies that all the rift strain estimates performed until now might be underestimated. From the comparative analysis of the two faulted regions (Phlegethon Catena and Claritas Fossae), we show that local and regional dip variabilities may exist on Mars. This reinforces the idea that the amount of extension associated with Martian rifts must be reconsidered. We also demonstrate the advantages of performing a comparative morphometric analysis of fault scarps. This approach enables the reconstruction of the faults scarps degradation history and can be used to evaluate how environmental conditions changed through time. After modeling the degradation of the fault scarps at the two sites we conclude that the observed morphometric variations are mainly due to the different faulting ages in an environment characterized by low scarp degradation rates ( 4 × 10 ? 3 m 2 / kyr ) over the last 3 Ga.

David A. Vaz; Mauro G. Spagnuolo; Simone Silvestro

2014-01-01T23:59:59.000Z

335

Calculating the probability of injected carbon dioxide plumes encountering faults  

SciTech Connect (OSTI)

One of the main concerns of storage in saline aquifers is leakage via faults. In the early stages of site selection, site-specific fault coverages are often not available for these aquifers. This necessitates a method using available fault data to estimate the probability of injected carbon dioxide encountering and migrating up a fault. The probability of encounter can be calculated from areal fault density statistics from available data, and carbon dioxide plume dimensions from numerical simulation. Given a number of assumptions, the dimension of the plume perpendicular to a fault times the areal density of faults with offsets greater than some threshold of interest provides probability of the plume encountering such a fault. Application of this result to a previously planned large-scale pilot injection in the southern portion of the San Joaquin Basin yielded a 3% and 7% chance of the plume encountering a fully and half seal offsetting fault, respectively. Subsequently available data indicated a half seal-offsetting fault at a distance from the injection well that implied a 20% probability of encounter for a plume sufficiently large to reach it.

Jordan, P.D.

2011-04-01T23:59:59.000Z

336

Field's Point Wastewater Treatment Facility (Narragansett Bay Commission) |  

Open Energy Info (EERE)

Field's Point Wastewater Treatment Facility (Narragansett Bay Commission) Field's Point Wastewater Treatment Facility (Narragansett Bay Commission) Jump to: navigation, search Name Field's Point Wastewater Treatment Facility (Narragansett Bay Commission) Facility Field's Point Wastewater Treatment Facility (Narragansett Bay Commission) Sector Wind energy Facility Type Community Wind Facility Status In Service Owner Gilbane Building Company Developer Narragansett Bay Commission Energy Purchaser Field's Point Location Providence RI Coordinates 41.79260859°, -71.3896966° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.79260859,"lon":-71.3896966,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

337

Market Channels and Value Added to Fish Landed at Monterey Bay Area Ports  

E-Print Network [OSTI]

Sample Input-Output Data to Port Level Summaries with PacFINMonterey Bay area (MBA) ports: Moss Landing, Monterey andlanded at Monterey Bay ports (i.e. , Moss Landing, Monterey

Pomeroy, Caroline; Dalton, Michael

2005-01-01T23:59:59.000Z

338

Hydrodynamic models for San Francisco Bay: An overview of what we can model, when  

E-Print Network [OSTI]

on the domain (SF Bay) #12;A Grid: Northern SF Bay/Golden Gate ChuaandFringer(2011) Finest resolution: 10 m average Thermal front near Dumbarton Bridge #12;More complicated models: Sediment transport in South SF

339

E-Print Network 3.0 - andrew bay florida Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Florida Bay... Interagency Florida Bay Science Program by Donald F. Boesch, Neal E. Armstrong, James E. Cloern, Linda A... . Deegan, Steven C. McCutcheon, Ronald D. Perkins, and...

340

Energy Secretary Steven Chu to Travel to Bay Area to Highlight...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Chu to Travel to Bay Area to Highlight State of the Union Address, Commitment to Clean Energy Energy Secretary Steven Chu to Travel to Bay Area to Highlight State of the Union...

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Galveston Bay Biodiesel LP GBB | Open Energy Information  

Open Energy Info (EERE)

Galveston Bay Biodiesel LP GBB Galveston Bay Biodiesel LP GBB Jump to: navigation, search Name Galveston Bay Biodiesel LP (GBB) Place Houston, Texas Product Developer of a 75.8m litre per year biodiesel facility on the Galveston Bulk Terminal site, located on Galveston Island. Coordinates 29.76045°, -95.369784° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":29.76045,"lon":-95.369784,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

342

Chesapeake Bay Restoration Act (Maryland) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Restoration Act (Maryland) Restoration Act (Maryland) Chesapeake Bay Restoration Act (Maryland) < Back Eligibility Agricultural Commercial Construction Developer Industrial Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Maryland Program Type Environmental Regulations Provider Maryland Department of the Environment This legislation sets limits on development near Chesapeake Bay as well as on dredging and the deposition of dredged material into the bay. The legislation establishes the Cox Creek Citizens Oversight Committee (now mostly defunct); the Hart-Miller-Pleasure Island Oversight Committee, which provides oversight and monitoring of the future development, use, and

343

EIS-0494: Excelerate Liquefaction Solutions Lavaca Bay LNG Project, Calhoun  

Broader source: Energy.gov (indexed) [DOE]

4: Excelerate Liquefaction Solutions Lavaca Bay LNG Project, 4: Excelerate Liquefaction Solutions Lavaca Bay LNG Project, Calhoun and Jackson Counties, Texas EIS-0494: Excelerate Liquefaction Solutions Lavaca Bay LNG Project, Calhoun and Jackson Counties, Texas SUMMARY The Federal Energy Regulatory Commission (FERC) is preparing, with DOE as a cooperating agency, an EIS to analyze the potential environmental impacts of a proposal to construct and operate a liquefied natural gas terminal consisting of two floating liquefaction, storage and offloading units and a 29-mile pipeline header system to transport natural gas from existing pipeline systems to the LNG terminal facilities. PUBLIC COMMENT OPPORTUNITIES None at this time. DOCUMENTS AVAILABLE FOR DOWNLOAD March 12, 2013 EIS-0494: Notice of Intent to Prepare an Environmental Impact Statement

344

Winchester Bay, Oregon: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Winchester Bay, Oregon: Energy Resources Winchester Bay, Oregon: Energy Resources (Redirected from Winchester Bay, OR) Jump to: navigation, search Equivalent URI DBpedia Coordinates 43.6770608°, -124.1748369° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":43.6770608,"lon":-124.1748369,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

345

City of Sturgeon Bay, Wisconsin (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Sturgeon Bay, Wisconsin (Utility Company) Sturgeon Bay, Wisconsin (Utility Company) Jump to: navigation, search Name Sturgeon Bay City of Place Wisconsin Utility Id 18249 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes ISO MISO Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Service Commercial General Service TOU - 7am - 7pm Commercial General Service TOU - 8am - 8pm Commercial General Service TOU - 9am - 9pm Commercial General Service Three-phase Commercial General Service Three-phase TOU - 7am - 7pm Commercial

346

Bay Resource Management Center Biomass Facility | Open Energy Information  

Open Energy Info (EERE)

Center Biomass Facility Center Biomass Facility Jump to: navigation, search Name Bay Resource Management Center Biomass Facility Facility Bay Resource Management Center Sector Biomass Facility Type Municipal Solid Waste Location Bay County, Florida Coordinates 30.1805306°, -85.684578° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":30.1805306,"lon":-85.684578,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

347

Relaxed fault detection and isolation: An application to a nonlinear case study  

Science Journals Connector (OSTI)

Given a number of possibly concurrent faults (and disturbances) that may affect a nonlinear dynamic system, it may not be possible to solve the standard fault detection and isolation (FDI) problem, i.e., to detect and isolate each single fault from all ... Keywords: Fault detection and isolation, Fault sets, Geometric conditions, Nonlinear systems, Robot manipulators

Raffaella Mattone; Alessandro De Luca

2006-01-01T23:59:59.000Z

348

Type E: Extensional Tectonic, Fault-Controlled Resource | Open Energy  

Open Energy Info (EERE)

Type E: Extensional Tectonic, Fault-Controlled Resource Type E: Extensional Tectonic, Fault-Controlled Resource Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Type E: Extensional Tectonic, Fault-Controlled Resource Dictionary.png Type E: Extensional Tectonic, Fault-Controlled Resource: No definition has been provided for this term. Add a Definition Brophy Occurrence Models This classification scheme was developed by Brophy, as reported in Updating the Classification of Geothermal Resources.[1] Type A: Magma-heated, Dry Steam Resource Type B: Andesitic Volcanic Resource Type C: Caldera Resource Type D: Sedimentary-hosted, Volcanic-related Resource Type E: Extensional Tectonic, Fault-Controlled Resource Type F: Oceanic-ridge, Basaltic Resource Extensional-tectonic, fault-controlled resources typically result from a

349

Similarity Matching Techniques for Fault Diagnosis in Automotive Infotainment Electronics  

E-Print Network [OSTI]

Fault diagnosis has become a very important area of research during the last decade due to the advancement of mechanical and electrical systems in industries. The automobile is a crucial field where fault diagnosis is given a special attention. Due to the increasing complexity and newly added features in vehicles, a comprehensive study has to be performed in order to achieve an appropriate diagnosis model. A diagnosis system is capable of identifying the faults of a system by investigating the observable effects (or symptoms). The system categorizes the fault into a diagnosis class and identifies a probable cause based on the supplied fault symptoms. Fault categorization and identification are done using similarity matching techniques. The development of diagnosis classes is done by making use of previous experience, knowledge or information within an application area. The necessary information used may come from several sources of knowledge, such as from system analysis. In this paper similarity matching tec...

Kabir, Mashud

2009-01-01T23:59:59.000Z

350

Exploring the Environmental Effects of Shale Gas Development in the Chesapeake Bay Watershed  

E-Print Network [OSTI]

Exploring the Environmental Effects of Shale Gas Development in the Chesapeake Bay Watershed STAC Committee). 2013. Exploring the environmental effects of shale gas development in the Chesapeake Bay of shale gas development in the Chesapeake Bay Watershed. The purpose of this workshop was to engage

351

Population and Production Estimates for Decapod Crustaceans in Wetlands of Galveston Bay, Texas  

E-Print Network [OSTI]

Population and Production Estimates for Decapod Crustaceans in Wetlands of Galveston Bay, Texas in regularly flooded wetlands of lower Galveston Bay, Texas, with data on small-scale (1�50- m) distribution sizes within shallow wetland habitats of the Galveston Bay system in Texas by combining regression

352

FACTORS AFFECTING MACROPHYTE AND FISH DISTRIBUTION IN COASTAL WETLANDS OF GEORGIAN BAY  

E-Print Network [OSTI]

FACTORS AFFECTING MACROPHYTE AND FISH DISTRIBUTION IN COASTAL WETLANDS OF GEORGIAN BAY #12;FACTORS AFFECTING MACROPHYTE AND FISH DISTRIBUTION IN COASTAL WETLANDS OF GEORGIAN BAY By MAJA CVETKOVIC, B and fish distribution in coastal wetlands of Georgian Bay AUTHOR: Maja Cvetkovic, B.Sc. (Mc

McMaster University

353

Final Independent External Peer Review for the Biscayne Bay Coastal Wetlands Project  

E-Print Network [OSTI]

Final Independent External Peer Review for the Biscayne Bay Coastal Wetlands Project Implementation-TERM ANALYSIS SERVICE (STAS) on Final Independent External Peer Review Report Biscayne Bay Coastal Wetlands COASTAL WETLANDS PROJECT IMPLEMENTATION REPORT EXECUTIVE SUMMARY The Biscayne Bay Coastal Wetlands (BBCW

US Army Corps of Engineers

354

In-situ stress and fracture permeability in a fault-hosted geothermal reservoir at Dixie Valley, Nevada  

SciTech Connect (OSTI)

As part of a study relating fractured rock hydrology to in-situ stress and recent deformation within the Dixie Valley Geothermal Field, borehole televiewer logging and hydraulic fracturing stress measurements were conducted in a 2.7-km-deep geothermal production well (73B-7) drilled into the Stillwater fault zone. Borehole televiewer logs from well 73B-7 show numerous drilling-induced tensile fractures, indicating that the direction of the minimum horizontal principal stress, S{sub hmin}, is S57{degrees}E. As the Stillwater fault at this location dips S50{degrees}E at {approximately}53{degrees}, it is nearly at the optimal orientation for normal faulting in the current stress field. Analysis of the hydraulic fracturing data shows that the magnitude of S{sub hmin} is 24.1 and 25.9 MPa at 1.7 and 2.5 km, respectively. In addition, analysis of a hydraulic fracturing test from a shallow well 1.5 km northeast of 73B-7 indicates that the magnitude of S{sub hmin} is 5.6 MPa at 0.4 km depth. Coulomb failure analysis shows that the magnitude of S{sub hmin} in these wells is close to that predicted for incipient normal faulting on the Stillwater and subparallel faults, using coefficients of friction of 0.6-1.0 and estimates of the in-situ fluid pressure and overburden stress. Spinner flowmeter and temperature logs were also acquired in well 73B-7 and were used to identify hydraulically conductive fractures.

Hickman, S. [Geological Survey, Menlo Park, CA (United States); Barton, C.; Zoback, M. [Stanford Univ., CA (United States)] [and others

1997-12-31T23:59:59.000Z

355

Fault diagnosis and management system for switched reluctance motor drives  

Science Journals Connector (OSTI)

An effective detection and diagnosis of faults is desirable for online condition monitoring, assessment, product quality assurance and improved operational efficiency of Switched Reluctance Motor (SRM) drives. The proposed fault diagnosis and management system uses the measured phase voltages, currents and speed of the motor. In this article, a Matlab/Simulink model-based fault diagnosis system is developed and simulated for SRM drive. The simulation results show that the SRM drive is capable of operating under faulty conditions.

S. Vijayan; S. Paramasivam

2008-01-01T23:59:59.000Z

356

Fault Detection and Diagnosis Method for VAV Terminal Units  

E-Print Network [OSTI]

: Air density [kg/m3] NOMENCLATURE REFERENCES 1) IEA Annex 25, Building Optimization and Fault Diagnosis Source Book, Eds. J. Hyvarinen and S. Karki, Technical Research Center of Finland, 1996 2) Harunori Yoshida: Typical Faults of Air Conditioning..., IEA Annex 34 ?Detection and Diagnosis Methods in Real Building?, Eds. A. Dexter and J. Pakanen, Section C.2, pp.143-148, 2001 6) Harunori Yoshida, Sanjay Kumar, Yasunori Morita: Online Fault Detection and Diagnosis in VAV Air Handling Unit by RARX...

Miyata, M.; Yoshida, H.; Asada, M.; Wang, F.; Hashiguchi, S.

2004-01-01T23:59:59.000Z

357

Enterprise Zone Program (Alabama) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Alabama) Alabama) Enterprise Zone Program (Alabama) < Back Eligibility Commercial Construction Industrial Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Alabama Program Type Enterprise Zone Provider Alabama Department of Economic and Community Affairs The Enterprise Zone Program provides certain tax incentives to corporations, partnerships and proprietorships that locate or expand within designated Enterprise Zones. In addition to state-level tax incentives, businesses may also receive local tax and non-tax incentives for locating or expanding within a designated Enterprise Zone. Section 5 of the Alabama Enterprise Zone Program offers the following tax incentives: Credit based

358

Renewable Energy Renaissance Zones | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Renewable Energy Renaissance Zones Renewable Energy Renaissance Zones Renewable Energy Renaissance Zones < Back Eligibility Commercial Industrial Local Government Savings Category Bioenergy Solar Buying & Making Electricity Alternative Fuel Vehicles Heating & Cooling Swimming Pool Heaters Water Heating Commercial Heating & Cooling Heating Wind Maximum Rebate None Program Info Start Date 07/12/2006 State Michigan Program Type Industry Recruitment/Support Rebate Amount 100% abatement of Michigan Business Tax, state education tax, personal and real property taxes, and local income taxes Provider Michigan Economic Development Corporation In 2006, Michigan enacted legislation allowing for the creation of Renewable Energy Renaissance Zones (RERZ). Renaissance zones -- renewable energy renaissance zones are just one type -- offer significant tax

359

Enterprise Zone Program (Louisiana) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Enterprise Zone Program (Louisiana) Enterprise Zone Program (Louisiana) Enterprise Zone Program (Louisiana) < Back Eligibility Commercial Construction Developer Fuel Distributor Industrial Installer/Contractor Institutional Investor-Owned Utility Nonprofit Retail Supplier Systems Integrator Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Louisiana Program Type Corporate Tax Incentive Enterprise Zone Provider Louisiana Economic Development The Enterprise Zone Program is a jobs incentive program providing Louisiana income and franchise tax credits to businesses hiring at least 35% of net, new jobs from targeted groups. Enterprise Zones (EZs) are areas with high unemployment, low income, or a high percentage of residents receiving some

360

Environmental management inventory of Galveston Bay. Final report  

SciTech Connect (OSTI)

The purpose of the report is to provide an inventory of those agencies and laws along with their associated regulations, that constitute the regulatory framework for environmental protection of Galveston Bay, one of the estuaries of national significance covered under the 1987 law. The inventory is largely descriptive, serving as the first phase in a larger project which will ultimately evaluate the effectiveness of the existing regulatory framework. That assessment in turn will form the basis for the Comprehensive Conservation and Management Plan as well as for policy recommendations to improve the coordination of environmental management of the Bay.

Hadden, S.G.

1992-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Connection of the Panama fracture zone with the Galapagos rift zone, eastern tropical Pacific  

Science Journals Connector (OSTI)

Magnetic data recently collected in the eastern tropical Pacific confirm that the Galapagos rift zone is connected to the Panama fracture zone by a short north-south...

Paul J. Grim

1970-08-01T23:59:59.000Z

362

Unsaturated Zone and Saturated Zone Transport Properties (U0100)  

SciTech Connect (OSTI)

This Analysis/Model Report (AMR) summarizes transport properties for the lower unsaturated zone hydrogeologic units and the saturated zone at Yucca Mountain and provides a summary of data from the Busted Butte Unsaturated Zone Transport Test (UZTT). The purpose of this report is to summarize the sorption and transport knowledge relevant to flow and transport in the units below Yucca Mountain and to provide backup documentation for the sorption parameters decided upon for each rock type. Because of the complexity of processes such as sorption, and because of the lack of direct data for many conditions that may be relevant for Yucca Mountain, data from systems outside of Yucca Mountain are also included. The data reported in this AMR will be used in Total System Performance Assessment (TSPA) calculations and as general scientific support for various Process Model Reports (PMRs) requiring knowledge of the transport properties of different materials. This report provides, but is not limited to, sorption coefficients and other relevant thermodynamic and transport properties for the radioisotopes of concern, especially neptunium (Np), plutonium (Pu), Uranium (U), technetium (Tc), iodine (I), and selenium (Se). The unsaturated-zone (UZ) transport properties in the vitric Calico Hills (CHv) are discussed, as are colloidal transport data based on the Busted Butte UZTT, the saturated tuff, and alluvium. These values were determined through expert elicitation, direct measurements, and data analysis. The transport parameters include information on interactions of the fractures and matrix. In addition, core matrix permeability data from the Busted Butte UZTT are summarized by both percent alteration and dispersion.

J. Conca

2000-12-20T23:59:59.000Z

363

High Temperature Superconducting Fault Current Limiter for Utility Applications  

Science Journals Connector (OSTI)

One of the most near term High Temperature Superconductor (HTS) applications is the Fault Current Limiter (FCL). It is a device that...

E. M. W. Leung; G. W. Albert; M. Dew…

1997-01-01T23:59:59.000Z

364

The northwest extension of the Meers Fault in southwestern Oklahoma  

E-Print Network [OSTI]

unmapped terrace deposits, a trench, and creek banks along an extended N60W trending line in Kiowa County, Oklahoma, strongly suggests that the Meers Fault has an active northwest extension of about 30km which bifurcates in the Sugar Creek area... Fault Study Area The study area covers about 100 square miles and it is located about 20 mi N45W of Lawton, Oklahoma, primarily in Kiowa and Comanche counties (TSN, R14W and R15W) (Figure 7). The Meers Fault is the south-bounding fault of the complex...

Cetin, Hasan

2012-06-07T23:59:59.000Z

365

Active Fault Controls At High-Temperature Geothermal Sites- Prospectin...  

Open Energy Info (EERE)

the level of unrecognized active faults present in these areas. Analysis of low-sun-angle aerial photography acquired over the Needle Rocks, Astor Pass, Empire, and Lee...

366

Controls on Fault-Hosted Fluid Flow: Preliminary Results from...  

Open Energy Info (EERE)

Results from the Coso Geothermal Field, CA Abstract cap rock, permeability, fault, fracture, clay, Coso Authors Davatzes, N.C.; Hickman and S.H. Published Geothermal Resource...

367

High-Resolution Aeromagnetic Survey to Image Shallow Faults,...  

Open Energy Info (EERE)

Valley Geothermal Area Regions (0) Retrieved from "http:en.openei.orgwindex.php?titleHigh-ResolutionAeromagneticSurveytoImageShallowFaults,DixieValleyGeothermalField...

368

Application of machine learning technique in wind turbine fault diagnosis.  

E-Print Network [OSTI]

??In this study, a machine learning technique called anomaly detection is employed for wind turbine bearing fault detection. Basically, the anomaly detection algorithm is used… (more)

Purarjomandlangrudi, Afrooz

2014-01-01T23:59:59.000Z

369

Inventory and analysis of bay management structure for the Corpus Christi Bay National Estuary Program study area  

SciTech Connect (OSTI)

This report characterizes the existing resource management framework for the Corpus Christi Bay National Estuary Program (CCBNEP) study area. Historical and current regulatory and non-regulatory approaches to resource management were examined, and an identification made of the significant gaps or overlaps in organizational roles and authorities. Efforts were taken to coordinate the Base Program Analysis with that for the Galveston Bay NEP, the Texas Coastal Management Program, and other similar projects, to both build upon and ensure that efforts are not duplicated.

Richard, B.; Bacon, E.; Dietz, R.; DeMoors, K.; Needham, K.

1996-02-01T23:59:59.000Z

370

The Border Cities Enterprise Zone Program (Minnesota)  

Broader source: Energy.gov [DOE]

The Border Cities Enterprise Zone Program provides business tax credits to businesses that invest, develop, expand, and create jobs in identified Border-Cities Enterprise Zones. Companies may be...

371

Farmland Security Zone | Open Energy Information  

Open Energy Info (EERE)

Zone Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- OtherOther: Farmland Security ZoneLegal Abstract California Department of Conservation,...

372

Enterprise Zone Sales Tax Exemption (Kansas)  

Broader source: Energy.gov [DOE]

The Enterprise Zone Sales Tax Exemption offers businesses located in such economic development zones a 100 percent sales tax exemption on the purchase of labor and materials to construct or remodel...

373

Local Option- Rural Renewable Energy Development Zones  

Broader source: Energy.gov [DOE]

Cities, counties, or several contiguous counties in Oregon can set up Rural Renewable Energy Development Zones. The zone can only cover territory outside of the urban growth boundary of any large...

374

Application of fuzzy SOFM neural network and rough set theory on fault diagnosis for rotating machinery  

Science Journals Connector (OSTI)

This paper presents a new method that applies fuzzy logic, rough set theory and SOFM neural network to rotating machinery fault diagnosis. In this method, firstly, relationships between the fault causations and fault symptoms are established by fuzzy ...

Dongxiang Jiang; Kai Li; Gang Zhao; Jinhui Diao

2005-05-01T23:59:59.000Z

375

Feng shui of supercomputer memory: positional effects in DRAM and SRAM faults  

Science Journals Connector (OSTI)

Several recent publications confirm that faults are common in high-performance computing systems. Therefore, further attention to the faults experienced by such computing systems is warranted. In this paper, we present a study of DRAM and SRAM faults ...

Vilas Sridharan; Jon Stearley; Nathan DeBardeleben; Sean Blanchard; Sudhanva Gurumurthi

2013-11-01T23:59:59.000Z

376

The structure and evolution of small-displacement strike-slip faults in porous sandstone  

E-Print Network [OSTI]

relationship between the progressive addition of subsidiary fault segments (deformation bands) and earlier-formed linkage structures. The along-strike variability and distribution of fault structure are documented and used to assess the role of early fault...

Schafer, Kirk Wyatt

2012-06-07T23:59:59.000Z

377

Research on Fault Diagnosis of Marine Diesel Engine Based on Integrated Similarity  

Science Journals Connector (OSTI)

In order to guarantee the normal operation of marine, an effective fault diagnosis model need to ... to determine the reason causing the fault of marine diesel engine. According to the problem of fault diagnosis ...

Yanyou Chai; Xiuyan Peng; Liufeng Xu; Jiuyu Shi

2011-01-01T23:59:59.000Z

378

Effects of burial history, rock ductility and recovery magnitude on inversion of normal faulted strata  

E-Print Network [OSTI]

reactivation of the normal faults may occur during coaxial contraction even though such faults are unfavorably oriented assuming typical rock friction behavior and a homogeneous stress state. Localized reverse slip on normal faults is favored when strata...

Kuhle, Nathan John

2012-06-07T23:59:59.000Z

379

Fault tolerant control of homopolar magnetic bearings and circular sensor arrays  

E-Print Network [OSTI]

Fault tolerant control can accommodate the component faults in a control system such as sensors, actuators, plants, etc. This dissertation presents two fault tolerant control schemes to accommodate the failures of power amplifiers and sensors in a...

Li, Ming-Hsiu

2006-04-12T23:59:59.000Z

380

Neural Network-Based Classification of Single-Phase Distribution Transformer Fault Data  

E-Print Network [OSTI]

The ultimate goal of this research is to develop an online, non-destructive, incipient fault detection system that is able to detect incipient faults in transformers and other electric equipment before the faults become catastrophic...

Zhang, Xujia

2006-08-16T23:59:59.000Z

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Eastern Energy Zones Mapping Tool  

Broader source: Energy.gov [DOE]

The Eastern Interconnection States’ Planning Council (EISPC) has released the Energy Zones (EZ) Mapping Tool, a free, web-based interactive tool that will help states and other stakeholders in the Eastern Interconnection identify geographic areas suitable for the development of clean energy resources (natural gas, sequestration or utilitization locations for C02 from coal, nuclear, and renewable) which can potentially provide significant amounts of new electric power generation.

382

Curiosity's Fault Tolerant Wakeup and Shutdown Design  

Science Journals Connector (OSTI)

Abstract Curiosity spends roughly 70% of the day “sleeping”, in order to recharge the batteries from the nuclear power source. The system is designed to ensure the Rover goes to sleep and wakes back up to continue science and engineering activities. Additionally, the design is robust to off-nominal situations that may need additional actions performed by both hardware and software to ensure the Rover can communicate with the Earth. This paper describes nominal and off-nominal behavioral patterns, fault tolerance features designed into the Rover system (hardware and software), several off-nominal scenarios that are accommodated by the design, and some lessons learned from this development effort.

Tracy A. Neilson; James A. Donaldson

2014-01-01T23:59:59.000Z

383

Fault current limiters and power switches  

SciTech Connect (OSTI)

Five papers give an overview of the Los Alamos National Lab`s collaboration with private industry and universities in developing High-Temperature Superconductor (HTS) Devices. Highlighted is the lab`s general approach and technical progress towards: design and fabrication of HTS current leads; high gradient magnetic separation for treatment of drinking and waste water; development of coils based on superconductor tape windings; testing of a HTS fault current limiter; and AC loss measuments of multifilament layered HTS conductors. Listed for each of these projects are commercial and university research/development partners along with the proposed projects for FY 1995.

Boenig, H. [Los Alamos National Lab., NM (United States)

1994-07-29T23:59:59.000Z

384

Bayes Net Toolbox practical Charles Fox, University of Sheffield  

E-Print Network [OSTI]

this network (which is a Directed Acyclic graph, or 'DAG'), we create an adjacency matrix: N = 4 %the number of nodes in the network dag = zeros(N,N) %connectivity matrix for the net (directed acyclic graph) C = 1 matlab >>cd bayesnet >>cd FullBNT1.0.4/ >>addpath(genpathKPM(pwd)) Creating your first Bayes net

Barker, Jon

385

Covered Product Category: Industrial Luminaires (High/Low Bay)  

Broader source: Energy.gov [DOE]

The Federal Energy Management Program (FEMP) provides acquisition guidance and Federal efficiency requirements for Industrial Luminaires (High/Low Bay). Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

386

Empirical Bayes approach to improve wavelet thresholding for image noise  

E-Print Network [OSTI]

Empirical Bayes approach to improve wavelet thresholding for image noise reduction Maarten Jansen thresholding for image noise reduction Maarten Jansen Adhemar Bultheel Report TW 296, October 1999 Department to improve wavelet thresholding for image noise reduction Maarten Jansen and Adhemar Bultheel Department

Jansen, Maarten

387

Vicksburg, Frio successes lift Galveston Bay area prospects  

SciTech Connect (OSTI)

Tertiary plays are yielding gas and condensate reserves in Galveston and Trinity bays and adjacent Galveston and Chambers counties along the Upper Texas Gulf Coast. The area south and southeast of Houston has long been productive of gas mainly from Upper Frio sands. Operators armed with modern geophysical techniques are now targeting reserves in deeper Frio and Vicksburg horizons. Interpretation of 3D seismic data is being used on some projects, and 2D data and AVO analysis have also been helpful. TransTexas Gas Corp., Houston, believes it has encountered large potential reserves of high pressure gas in Vicksburg in Galveston Bay just north of Texas City. Several operators are drilling exploratory wells within 5--10 miles west of TransTexas` indicated discovery. Enserch Exploration Inc., Dallas, and Vintage Petroleum Corp., Tulsa, are successfully exploring Trinity Bay and northeastern Galveston Bay in Chambers County southwest of Anahuac. Elsewhere in Chambers County, Columbus Energy Corp., Denver, completed a Frio F-16 deeper pool gas/condensate discovery beneath giant Anahuac oil field. Several operators are reporting success at gas/condensate tests across the county. Exploration activities are discussed in these deposits.

Petzet, G.A.

1997-08-11T23:59:59.000Z

388

The health of Florida Bay, which lies be-  

E-Print Network [OSTI]

r/fi .V u. r V \\ The health of Florida Bay, which lies be- tween the mainland and the Florida Keys, is dependent on the health of the rest of the Everglades. the aftcniooii (il June 2, with ;i tlid\\ nt a pen onto increasingly dangerous arterial roads. Even the head of the East Central Florida Regional Planning

Handy, Susan L.

389

EA-1995: Trestle Bay Ecosystem Restoration Project, Clatsop County, Oregon  

Broader source: Energy.gov [DOE]

The U.S. Army Corps of Engineers is preparing, with DOE’s Bonneville Power Administration (BPA) as a cooperating agency, an EA that evaluates the potential environmental impacts of a proposal to improve estuary habitat in Trestle Bay. BPA’s proposed action is to partially fund the proposal.

390

Mission Bay Housing Services Bicycle Storage Procedures and Policies  

E-Print Network [OSTI]

Mission Bay Housing Services Bicycle Storage Procedures and Policies Procedures All bicycles must Garage. To contact the office call: (415) 476-1511. You will be issued a bicycle sticker, which should be displayed on your bicycle at all times. Once your bike has been registered, visit the Housing Services

Yamamoto, Keith

391

Measuring Heterogeneity in Forensic Databases Using Hierarchical Bayes Models  

E-Print Network [OSTI]

Measuring Heterogeneity in Forensic Databases Using Hierarchical Bayes Models By Kathryn Roeder, as currently defined, do not uniquely identify individuals. For criminal cases involving DNA evidence, forensic­ ing profiles are based on reference populations maintained by forensic testing laboratories. Each

392

Studies on the anatomy and ecological distribution of Dentalium texasianum Philippi 1848 in West Bay of the Galveston Bay complex (Mollusca: scaphopoda  

E-Print Network [OSTI]

, L''uis pass . -oz~ Trini River ~p ~~ xcv at Hwy 46 Fnckinson P ay Lower ~C raise ton Bay (~ 30 6 end ot Seawall T. P) We t' Beach Foti'ets Isl J 9d'45'W 9' 30'W 12 bottom. Penetration was only several centimeters, depending... included surface salinity values from West Bay, East Bay, and Lower Galveston Bay which were taken during three days in March, 1926 (Table 1, pg. 20) . Hopkins (1931) pub- lished water temperature, salinity, and pH values from March to August, 1929...

Peterson, Larry Randal

2012-06-07T23:59:59.000Z

393

Fault Analysis at a Wind Power Plant for One Year of Observation: Preprint  

SciTech Connect (OSTI)

This paper analyzes the fault characteristics observed at a wind power plant, and the behavior of the wind power plant under fault events.

Muljadi, E.; Mills, Z.; Foster, R.; Conto, J.; Ellis, A.

2008-07-01T23:59:59.000Z

394

E-Print Network 3.0 - automated fault extraction Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

with extracted... automation, fault diagnosis, asset management, as well as power system modeling and simulation. 12;... 1 F Voltage Sag Data Utilization for Distribution Fault...

395

Fault Identification in Doubly Fed Induction Generator Using FFT and Neural Networks  

Science Journals Connector (OSTI)

This paper presents a fault identification system for doubly fed induction generator (DFIG). It considers cases of single phase ... with the PP to fault identification in the DFIG.

Marcelo Patrício de Santana…

2012-01-01T23:59:59.000Z

396

The Carolina Bay Restoration Project - Final Report 2000-2006.  

SciTech Connect (OSTI)

A Wetlands Mitigation Bank was established at SRS in 1997 as a compensatory alternative for unavoidable wetland losses. Prior to restoration activities, 16 sites included in the project were surveyed for the SRS Site Use system to serve as a protective covenant. Pre-restoration monitoring ended in Fall 2000, and post restoration monitoring began in the Winter/Spring of 2001. The total interior harvest in the 16 bays after harvesting the trees was 19.6 ha. The margins in the opencanopy, pine savanna margin treatments were thinned. Margins containing areas with immature forested stands (bay 5184 and portions of bay 5011) were thinned using a mechanical shredder in November 2001. Over 126 hectares were included in the study areas (interior + margin). Planting of two tree species and the transplanting of wetland grass species was successful. From field surveys, it was estimated that approximately 2700 Nyssa sylvatica and 1900 Taxodium distichum seedlings were planted in the eight forested bays resulting in an average planting density of ? 490 stems ha-1. One hundred seedlings of each species per bay (where available) were marked to evaluate survivability and growth. Wetland grass species were transplanted from donor sites on SRS to plots that ranged in size from 100 – 300 m2, depending on wetland size. On 0.75 and 0.6 meter centers, respectively, 2198 plugs of Panicum hemitomon and 3021 plugs Leersia hexandra were transplanted. New shoots originating from the stumps were treated with a foliar herbicide (Garlon® 4) during the summer of 2001 using backpack sprayers. Preliminary information from 2000-2004 regarding the hydrologic, vegetation and faunal response to restoration is presented in this status report.

Barton, Christopher

2007-12-15T23:59:59.000Z

397

Property:ASHRAE 169 Climate Zone Subtype | Open Energy Information  

Open Energy Info (EERE)

ASHRAE 169 Climate Zone Subtype ASHRAE 169 Climate Zone Subtype Jump to: navigation, search This is a property of type Page. Pages using the property "ASHRAE 169 Climate Zone Subtype" Showing 25 pages using this property. (previous 25) (next 25) A Abbeville County, South Carolina ASHRAE 169-2006 Climate Zone + Climate Zone Subtype A + Acadia Parish, Louisiana ASHRAE 169-2006 Climate Zone + Climate Zone Subtype A + Accomack County, Virginia ASHRAE 169-2006 Climate Zone + Climate Zone Subtype A + Ada County, Idaho ASHRAE 169-2006 Climate Zone + Climate Zone Subtype B + Adair County, Iowa ASHRAE 169-2006 Climate Zone + Climate Zone Subtype A + Adair County, Kentucky ASHRAE 169-2006 Climate Zone + Climate Zone Subtype A + Adair County, Missouri ASHRAE 169-2006 Climate Zone + Climate Zone Subtype A +

398

Property:ASHRAE 169 Climate Zone Number | Open Energy Information  

Open Energy Info (EERE)

Number Number Jump to: navigation, search This is a property of type Page. Pages using the property "ASHRAE 169 Climate Zone Number" Showing 25 pages using this property. (previous 25) (next 25) A Abbeville County, South Carolina ASHRAE 169-2006 Climate Zone + Climate Zone Number 3 + Acadia Parish, Louisiana ASHRAE 169-2006 Climate Zone + Climate Zone Number 2 + Accomack County, Virginia ASHRAE 169-2006 Climate Zone + Climate Zone Number 4 + Ada County, Idaho ASHRAE 169-2006 Climate Zone + Climate Zone Number 5 + Adair County, Iowa ASHRAE 169-2006 Climate Zone + Climate Zone Number 5 + Adair County, Kentucky ASHRAE 169-2006 Climate Zone + Climate Zone Number 4 + Adair County, Missouri ASHRAE 169-2006 Climate Zone + Climate Zone Number 5 + Adair County, Oklahoma ASHRAE 169-2006 Climate Zone + Climate Zone Number 3 +

399

Fault current limiter with shield and adjacent cores  

DOE Patents [OSTI]

In a fault current limiter (FCL) of a saturated core type having at least one coil wound around a high permeability material, a method of suppressing the time derivative of the fault current at the zero current point includes the following step: utilizing an electromagnetic screen or shield around the AC coil to suppress the time derivative current levels during zero current conditions.

Darmann, Francis Anthony; Moriconi, Franco; Hodge, Eoin Patrick

2013-10-22T23:59:59.000Z

400

Creep along the Imperial Fault, southern California, from GPS measurements  

E-Print Network [OSTI]

on a fault. [4] Located southwest of the Salton Sea (Figure 1), the Imperial Valley has experienced numerousCreep along the Imperial Fault, southern California, from GPS measurements Suzanne N. Lyons, Yehuda Positioning System (GPS) 46 geodetic monuments established by Imperial College, London, in a dense grid (half

Sandwell, David T.

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Fault Tolerant Oxygen Control of a Diesel Engine Air System  

E-Print Network [OSTI]

Fault Tolerant Oxygen Control of a Diesel Engine Air System Rainer Nitsche Matthias Bitzer control problem of a Diesel engine air system having a jammed Exhaust Gas Recirculation (EGR) valve of the air system. Keywords: Fault tolerant control, Diesel engine, Air system, Model-based trajectory

Paris-Sud XI, Université de

402

The faults that move during earthquakes do not always come  

E-Print Network [OSTI]

often live near active faults, because where there is a fault there is usually a water supply. And that means these places become part of major trade routes, like the Silk Roads across Asia from Xi urban building. What is even more frighten- ing is that in many parts of the world poor

Cipolla, Roberto

403

Fault detection and diagnosis capabilities of test sequence selection  

E-Print Network [OSTI]

Review Fault detection and diagnosis capabilities of test sequence selection methods based on the FSM model T Ramalingam*, Anindya Dast and K ThuIasiraman* Different test sequence selection methods resolution in diagnosing the fault. The test sequence selection methods are then compared based on the length

Thulsiraman, Krishnaiyan

404

Observations on the capability of the Criner fault, southern Oklahoma  

E-Print Network [OSTI]

of the Criner fault arises because of its proximity to the Meers fault, which is documented to have been reactivated within the last 1200 years. Such findings contradict the prevailing view that the inner continent of North America is a stable tectonic regime...

Williamson, Shawn Collin

2012-06-07T23:59:59.000Z

405

An investigation of Network Splitting for Fault Level Reduction  

E-Print Network [OSTI]

main methods for fault level reduction namely current limiting reactor, Is-limiter, superconducting term as it is relatively inexpensive and furthermore it has high reliability and flexibility. Modelling in the bus-section. The analysis shows that the fault current is sensitive to closure of the normally open

Watson, Andrew

406

Enterprise Zone Program (Georgia) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Georgia) Georgia) Enterprise Zone Program (Georgia) < Back Eligibility Agricultural Commercial Construction Developer Fuel Distributor General Public/Consumer Industrial Installer/Contractor Investor-Owned Utility Municipal/Public Utility Retail Supplier Rural Electric Cooperative Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Georgia Program Type Enterprise Zone Personal Tax Incentives Property Tax Incentive Provider Georgia Department of Community Affairs The Enterprise Zone Program provides various tax incentives to businesses within designated underdeveloped zones in rural or urban areas. The State Enterprise Zone program intends to improve geographic areas within cities

407

Enterprise Zones (Iowa) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Zones (Iowa) Zones (Iowa) Enterprise Zones (Iowa) < Back Eligibility Agricultural Commercial Construction Fuel Distributor Industrial Installer/Contractor Institutional Investor-Owned Utility Municipal/Public Utility Nonprofit Rural Electric Cooperative Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Iowa Program Type Enterprise Zone Industry Recruitment/Support Training/Technical Assistance Provider Iowa Economic Development Authority The Enterprise Zones Program is an incentive for business expansion designed to stimulate development by targeting economically distressed areas in Iowa. Through state and local tax incentives, businesses and developers are encouraged to make new investments, and create or retain

408

Dating of major normal fault systems using thermochronology- An example  

Open Energy Info (EERE)

Dating of major normal fault systems using thermochronology- An example Dating of major normal fault systems using thermochronology- An example from the Raft River detachment, Basin and Range, western United States Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Dating of major normal fault systems using thermochronology- An example from the Raft River detachment, Basin and Range, western United States Details Activities (1) Areas (1) Regions (0) Abstract: Application of thermochronological techniques to major normal fault systems can resolve the timing of initiation and duration of extension, rates of motion on detachment faults, timing of ductile mylonite formation and passage of rocks through the crystal-plastic to brittle transition, and multiple events of extensional unroofing. Here we determine

409

Recent earthquake sequences at Coso: Evidence for conjugate faulting and  

Open Energy Info (EERE)

earthquake sequences at Coso: Evidence for conjugate faulting and earthquake sequences at Coso: Evidence for conjugate faulting and stress loading near a geothermal field Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Recent earthquake sequences at Coso: Evidence for conjugate faulting and stress loading near a geothermal field Details Activities (1) Areas (1) Regions (0) Abstract: Two recent earthquake sequences near the Coso geothermal field show clear evidence of faulting along conjugate planes. We present results from analyzing an earthquake sequence occurring in 1998 and compare it with a similar sequence that occurred in 1996. The two sequences followed mainshocks that occurred on 27 November 1996 and 6 March 1998. Both mainshocks ruptured approximately colocated regions of the same fault

410

Definition: Apex or Salient of Normal Fault | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Apex or Salient of Normal Fault Jump to: navigation, search Dictionary.png Apex or Salient of Normal Fault Normal faults may intersect in the subsurface to form a fault apex or salient. Apices or salients of normal faults account for 3% of structural controls in the Great Basin.[2] View on Wikipedia Wikipedia Definition References ↑ James E. Faulds,Nicholas H. Hinz,Mark F. Coolbaugh,Patricia H. Cashman,Christopher Kratt,Gregory Dering,Joel Edwards,Brett Mayhew,Holly McLachlan. 2011. Assessment of Favorable Structural Settings of Geothermal Systems in the Great Basin, Western USA. In: Transactions. GRC Anual Meeting; 2011/10/23; San Diego, CA. Davis, CA: Geothermal Resources Council; p. 777-783

411

Overview: Zoning for Small Wind Turbines  

Wind Powering America (EERE)

Overview: Overview: Zoning for Small Wind Turbines Jim Green NREL ASES Small Wind Division Webinar January 17, 2008 2 Zoning Basics * Zoning is one form of land use law * Based on legal principle of "police power:" the power to regulate in order to promote the health, morals, safety, and general welfare of the community * Zoning authority originates from state laws called "zoning enabling legislation" - Standard Zoning Enabling Act, Dept. of Commerce, 1920s * Enabling legislation delegates land use authority to local jurisdictions, "Home Rule" - counties, parishes, boroughs, townships, municipalities, cities, villages, etc. 3 Zoning is Daunting * 3,034 counties (National Association of Counties) * 16,504 townships * 19,429 municipalities (National League of Cities)

412

Enhanced Enterprise Zones (Missouri) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Enhanced Enterprise Zones (Missouri) Enhanced Enterprise Zones (Missouri) Enhanced Enterprise Zones (Missouri) < Back Eligibility Commercial Industrial Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Missouri Program Type Enterprise Zone Corporate Tax Incentive Provider Missouri Department of Economic Development Enhanced Enterprise Zones aim at attracting new businesses or promoting an expansion of existing business in Missouri Enhanced Enterprise Zone. Tax credits will be an amount authorized by DED, based on the state economic benefit, supported by the number of new jobs, wages and new capital investment that the project will create. To qualify, individual business eligibility will be determined by the zone, based on creation of

413

Feb. 11, 2008 Advanced Fault Tolerance Solutions for High Performance Computing 1/47 Advanced Fault Tolerance Solutions  

E-Print Network [OSTI]

Feb. 11, 2008 Advanced Fault Tolerance Solutions for High Performance Computing 1/47 RAS RAS Advanced Fault Tolerance Solutions for High Performance Computing Christian Engelmann Oak Ridge National Solutions for High Performance Computing 2/47 · Nation's largest energy laboratory · Nation's largest

Engelmann, Christian

414

SODAR DATA FROM OYSTER BAY AT WINYAH BAY NATIONAL ESTUARINE RESEARCH RESERVE  

SciTech Connect (OSTI)

The SecondWind Triton® is a SODAR (SOnic Detection And Ranging) sonic wind profiler (Triton® sodar) system capable of profiling the wind characteristics up to 200m above the instrument. SODAR systems transmit acoustic chirps into the atmosphere and measure the backscattered signal returned to the device. The primary source of acoustic scattering is variations in air temperature, which cause changes in the refractive index of sound. By measuring the Doppler?shifted frequency of these returned signals, the Triton® can calculate the wind’s speed and direction for the volume of air above the instrument, measured at ten fixed heights, known as station heights. The Triton® is specifically designed for the purpose of wind energy resource assessment as it can remotely capture wind data at heights above ground where wind turbine rotors operate. The measurements made include horizontal wind speed and direction, vertical wind speed, and turbulence. Other integrated sensors provide time and location via GPS, barometric pressure, humidity, and the tilt of the instrument. The study area is located east of Georgetown, South Carolina in North Inlet ? Winyah Bay National Estuarine Research Reserve. The monitoring period for data in this report begins 5/14/2009 9:30:00 AM EST and ends 8/2/2010 11:40:00 AM EST.

Nichols, R.; Kohn, J.; Rigas, N.; Boessneck, E.; Kress, E.; Gayes, P.

2013-04-29T23:59:59.000Z

415

U.S. Climate Zones Map for Commercial Buildings  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

U.S. Climate Zone U. S. Climate Zones for 2003 CBECS: climate zones map Note:Map updated with corrections, February 2012 Further Explanation on How Climate Zones are Defined...

416

U.S. Climate Zones Map for Commercial Buildings  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

Past Climate Zones U. S. Climate Zones for 1979-1999 CBECS: climate zone map Return to Climate Zones for 2003 CBECS Return to CBECS Home Page Note:Map updated with corrections,...

417

Property:Buildings/ModelClimateZone | Open Energy Information  

Open Energy Info (EERE)

ModelClimateZone ModelClimateZone Jump to: navigation, search This is a property of type Page. It links to pages that use the form Buildings Model. The allowed values for this property are: Climate Zone 1A Climate Zone 1B Climate Zone 2A Climate Zone 2B Climate Zone 3A Climate Zone 3B Climate Zone 3C Climate Zone 4A Climate Zone 4B Climate Zone 4C Climate Zone 5A Climate Zone 5B Climate Zone 5C Climate Zone 6A Climate Zone 6B Climate Zone 7A Climate Zone 7B Climate Zone 8A Climate Zone 8B Pages using the property "Buildings/ModelClimateZone" Showing 12 pages using this property. G General Merchandise 2009 TSD Chicago High Plug Load 50% Energy Savings + Climate Zone 5A + General Merchandise 2009 TSD Chicago High Plug Load Baseline + Climate Zone 5A + General Merchandise 2009 TSD Chicago Low Plug Load 50% Energy Savings + Climate Zone 5A +

418

The effects of lithology and initial fault angle in physical models of fault-propagation folds  

E-Print Network [OSTI]

(1998). . . . 12 10 Principal stress directions within a layer moving through a ramp region of a thrust by Wiltschko (1979). . 14 Potential secondary fault trajectories interpreted from maximum shear stresses in theoretical models by Rodgers... Sandstone Data: Lead Configuration B. . 10 Layer Thickness Measurements ? Clay Configuration A . . . 91 11 Limb Dips: Configuration A Clay Models. . . 113 12 Fold Measurements: Configuration A Clay Models . . . 113 13 Sandstone Data: Clay Configuration...

McLain, Christopher Thomas

2012-06-07T23:59:59.000Z

419

Superconducting Fault Current Limiter for Transmission Voltage  

Science Journals Connector (OSTI)

Within a collaboration of American Superconductor, Siemens, Nexans and Southern California Edison one electrical phase of a resistive superconducting fault current limiter for the 115 kV transmission voltage level has been designed and manufactured. The active part of the limiter consists of 63 bifilar coils made of 12 mm wide steel-stabilized YBCO conductor and is housed in a cryostat operated at 5 bar and 74 K. The first phase was completely assembled and successfully subjected to power switching tests and high voltage tests. The basic design of the system and the test results are reported. The work was funded in part by US-DOE under Contract Number DE-FC26-07NT43243.

Hans-Peter Kraemer; Wolfgang Schmidt; Hong Cai; Bruce Gamble; David Madura; Tim MacDonald; Joe McNamara; Walther Romanosky; Greg Snitchler; Nicolas Lallouet; Frank Schmidt; Syed Ahmed

2012-01-01T23:59:59.000Z

420

Experimental study on characteristics of superconducting fault current limiters connected  

Science Journals Connector (OSTI)

Superconducting fault current limiters (SCFCLs) can reduce fault current; thus SCFCLs allow the capacity of circuit breakers to be reduced and lend flexibility to power system network designs. Furthermore, SCFCLs are expected to improve power system stability, as has been confirmed by some experiments. Therefore, various kinds of SCFCLs were proposed and have been studied. For introducing SCFCLs in power systems, there should be some specifications, such as the impedance, the trigger current level, and the recovery time. Fault analyses pointed out that accuracy of the trigger current level is required. A transformer type SCFCL with an adjustable trigger current level was proposed, designed, made, and tested. Then, limiting tests on three-phase SCFCLs by use of an artificial transmission line with a small generator were carried out. The test results indicated that at phase-to-phase faults, the SCFCLs for the fault phases do not always turn into the limiting mode. From two points of view, it is important to study characteristics of the series connection for SCFCLs: one is as mentioned above, and the other is that a series connection of some SCFCLs of small impedance may be installed in place of an SCFCL of larger impedance. This paper describes the results of limiting tests on two SCFCLs connected in series. The tests were carried out under some different conditions of fault currents, fault phases, and trigger current levels of SCFCLs. Some discussion on characteristics of series connection of SCFCLs appears also.

Hiroyuki Hatta; Tanzo Nitta; Tomomi Oide; Masakuni Chiba; Yasuyuki Shirai; Akihiro Mochida

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Ergodicity in natural earthquake fault networks  

Science Journals Connector (OSTI)

Numerical simulations have shown that certain driven nonlinear systems can be characterized by mean-field statistical properties often associated with ergodic dynamics [C. D. Ferguson, W. Klein, and J. B. Rundle, Phys. Rev. E 60, 1359 (1999); D. Egolf, Science 287, 101 (2000)]. These driven mean-field threshold systems feature long-range interactions and can be treated as equilibriumlike systems with statistically stationary dynamics over long time intervals. Recently the equilibrium property of ergodicity was identified in an earthquake fault system, a natural driven threshold system, by means of the Thirumalai-Mountain (TM) fluctuation metric developed in the study of diffusive systems [K. F. Tiampo, J. B. Rundle, W. Klein, J. S. Sá Martins, and C. D. Ferguson, Phys. Rev. Lett. 91, 238501 (2003)]. We analyze the seismicity of three naturally occurring earthquake fault networks from a variety of tectonic settings in an attempt to investigate the range of applicability of effective ergodicity, using the TM metric and other related statistics. Results suggest that, once variations in the catalog data resulting from technical and network issues are accounted for, all of these natural earthquake systems display stationary periods of metastable equilibrium and effective ergodicity that are disrupted by large events. We conclude that a constant rate of events is an important prerequisite for these periods of punctuated ergodicity and that, while the level of temporal variability in the spatial statistics is the controlling factor in the ergodic behavior of seismic networks, no single statistic is sufficient to ensure quantification of ergodicity. Ergodicity in this application not only requires that the system be stationary for these networks at the applicable spatial and temporal scales, but also implies that they are in a state of metastable equilibrium, one in which the ensemble averages can be substituted for temporal averages in studying their spatiotemporal evolution.

K. F. Tiampo; J. B. Rundle; W. Klein; J. Holliday; J. S. Sá Martins; C. D. Ferguson

2007-06-22T23:59:59.000Z

422

Experimental wrench faulting at confining pressure  

E-Print Network [OSTI]

-peak, peak, post-peak, pre-residual, and residual shear force (modified from Tchalenko, 1970, Fig. 3) . . . . . . . . . . . . . . . . . . . . . . . . . 14 Example of shear stress/shear d1splacement curve for spec1men 978, deformed at 50 MPa confin1ng... thin sect1ons of 0. 5 cm Indiana 11mestone veneer, deformed at 50 MPa confining pres- sure, and taken to 0. 54 cm shear d1splacement (spe- cimen 978). . . . . . . . . . . . . . . . . - . - . ~ 26 29 32 35 10. Shear zone fracture map sketched...

Bartlett, Wendy Louise

2012-06-07T23:59:59.000Z

423

Lakes by the Bay, Florida: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

the Bay, Florida: Energy Resources the Bay, Florida: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 25.5723287°, -80.3253308° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":25.5723287,"lon":-80.3253308,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

424

Suttons Bay, Michigan: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Suttons Bay, Michigan: Energy Resources Suttons Bay, Michigan: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 44.9766663°, -85.6506387° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":44.9766663,"lon":-85.6506387,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

425

Half Moon Bay, California: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Bay, California: Energy Resources Bay, California: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 37.4635519°, -122.4285862° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":37.4635519,"lon":-122.4285862,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

426

MHK Projects/Whiskey Bay | Open Energy Information  

Open Energy Info (EERE)

Whiskey Bay Whiskey Bay < MHK Projects Jump to: navigation, search << Return to the MHK database homepage Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":5,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"500px","height":"350px","centre":false,"title":"","label":"","icon":"File:Aquamarine-marker.png","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":30.4014,"lon":-91.6961,"alt":0,"address":"","icon":"http:\/\/prod-http-80-800498448.us-east-1.elb.amazonaws.com\/w\/images\/7\/74\/Aquamarine-marker.png","group":"","inlineLabel":"","visitedicon":""}]}

427

Discovery Bay, California: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Discovery Bay, California: Energy Resources Discovery Bay, California: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 37.9085357°, -121.6002291° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":37.9085357,"lon":-121.6002291,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

428

Morro Bay, California: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Morro Bay, California: Energy Resources Morro Bay, California: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 35.3658075°, -120.8499013° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":35.3658075,"lon":-120.8499013,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

429

The Daya Bay Reactor Neutrino Experiment Sees Evidence that Electron  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Science Highlights » 2013 Science Highlights » 2013 » The Daya Bay Reactor Neutrino Experiment Sees Evidence that Electron Neutrinos Turn into Muon Neutrinos High Energy Physics (HEP) HEP Home About Research Facilities Science Highlights Benefits of HEP Funding Opportunities Advisory Committees News & Resources Contact Information High Energy Physics U.S. Department of Energy SC-25/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-3624 F: (301) 903-2597 E: sc.hep@science.doe.gov More Information » June 2013 The Daya Bay Reactor Neutrino Experiment Sees Evidence that Electron Neutrinos Turn into Muon Neutrinos Surprisingly large effect greatly increases the probability that new neutrino experiments will be able to see the differences between matter and

430

Kawela Bay, Hawaii: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Kawela Bay, Hawaii: Energy Resources Kawela Bay, Hawaii: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 21.7033333°, -158.01° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":21.7033333,"lon":-158.01,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

431

Put-in-Bay, Ohio: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Put-in-Bay, Ohio: Energy Resources Put-in-Bay, Ohio: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 41.6542158°, -82.8207429° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.6542158,"lon":-82.8207429,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

432

Cutler Bay, Florida: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Cutler Bay, Florida: Energy Resources Cutler Bay, Florida: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 25.5783°, -80.3377° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":25.5783,"lon":-80.3377,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

433

MHK Projects/Swansea Bay | Open Energy Information  

Open Energy Info (EERE)

Swansea Bay Swansea Bay < MHK Projects Jump to: navigation, search << Return to the MHK database homepage Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":5,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"500px","height":"350px","centre":false,"title":"","label":"","icon":"File:Aquamarine-marker.png","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":51.5818,"lon":-3.89843,"alt":0,"address":"","icon":"http:\/\/prod-http-80-800498448.us-east-1.elb.amazonaws.com\/w\/images\/7\/74\/Aquamarine-marker.png","group":"","inlineLabel":"","visitedicon":""}]}

434

Runaway Bay, Texas: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Runaway Bay, Texas: Energy Resources Runaway Bay, Texas: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 33.1678941°, -97.8783696° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":33.1678941,"lon":-97.8783696,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

435

Tonka Bay, Minnesota: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Tonka Bay, Minnesota: Energy Resources Tonka Bay, Minnesota: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 44.9085741°, -93.5930133° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":44.9085741,"lon":-93.5930133,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

436

Hampton Bays, New York: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Hampton Bays, New York: Energy Resources Hampton Bays, New York: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 40.8689892°, -72.5175893° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.8689892,"lon":-72.5175893,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

437

South Bay, Florida: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Bay, Florida: Energy Resources Bay, Florida: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 26.6639559°, -80.7161701° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":26.6639559,"lon":-80.7161701,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

438

Nassau Bay, Texas: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Nassau Bay, Texas: Energy Resources Nassau Bay, Texas: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 29.5446753°, -95.0910413° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":29.5446753,"lon":-95.0910413,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

439

Microsoft Word - Green Bay Notes - FINAL.doc  

Broader source: Energy.gov (indexed) [DOE]

(DOE) (DOE) TRANSPORTATION EXTERNAL COORDINATION (TEC) WORKING GROUP MEETING September 13-14, 2006 Green Bay, WI Welcome and Meeting Overview The U.S. Department of Energy (DOE), Transportation External Coordination Working Group (TEC) held its 26 th meeting on September 13-14, 2006, in Green Bay, WI. One- hundred thirty-two participants, representing national, State, Tribal, and local government; industry; professional organizations; and other interested parties, met to address a variety of issues related to DOE's radioactive materials transportation activities. The TEC process includes the involvement of these key stakeholders in developing solutions to DOE transportation issues through their actual participation in the work product. These members provide continuing and improved coordination between DOE,

440

Buzzards Bay, Massachusetts: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Buzzards Bay, Massachusetts: Energy Resources Buzzards Bay, Massachusetts: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 41.7453829°, -70.618087° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.7453829,"lon":-70.618087,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Radiated seismic energy based on dynamic rupture models of faulting and Ralph J. Archuleta1  

E-Print Network [OSTI]

Radiated seismic energy based on dynamic rupture models of faulting Shuo Ma1 and Ralph J. Archuleta energy from three hypothetical crustal events, 30° dipping reverse fault, 60° dipping normal fault, and 0.34 MPa for the reverse, normal, and strike-slip faults, respectively. The energy distribution

Archuleta, Ralph

442

On-Line Fault Detection and Compensation of Hydraulic Driven Machines Using Modelling Techniques  

E-Print Network [OSTI]

On-Line Fault Detection and Compensation of Hydraulic Driven Machines Using Modelling Techniques C purpose of hydraulic driven machines as well as for the compensation of incipient faults where applicable: Modelling, Simulation, Hydraulic motors, Fault detection, Fault Compensation 1. Introduction Model

Thawonmas, Ruck

443

Dynamic neural network-based fault diagnosis of gas turbine engines  

Science Journals Connector (OSTI)

In this paper, a neural network-based fault detection and isolation (FDI) scheme is presented to detect and isolate faults in a highly nonlinear dynamics of an aircraft jet engine. Towards this end, dynamic neural networks (DNN) are first developed to ... Keywords: Aircraft jet engine, Bank of filters, Computational intelligence, Dynamic neural networks, Fault detection and isolation, Fault diagnosis, Multiple model schemes

S. Sina Tayarani-Bathaie; Z. N. Sadough Vanini; K. Khorasani

2014-02-01T23:59:59.000Z

444

Improving and Evaluating Differential Fault Analysis on LED with Algebraic Techniques  

E-Print Network [OSTI]

Improving and Evaluating Differential Fault Analysis on LED with Algebraic Techniques Xinjie Zhao.zhang,zshi,chm10010}@engr.uconn.edu Abstract--This paper proposes a fault analysis technique on LED by combining- ential fault analysis (ADFA). In ADFA on LED, we use DFA to deduce the possible fault differences

Shi, Zhijie Jerry

445

In situ measurement of the hydraulic diffusivity of the active Chelungpu Fault, Taiwan  

E-Print Network [OSTI]

.1. Boreholes of the Taiwan Chelungpu-Fault Drilling Project [6] The pair of boreholes used for this experiment shaking in the regions of large slip if the fault was sufficiently sealed. We investigate in situ in situ on an active large-scale fault. Hydraulic tests in deep bore- holes intersecting the Nojima fault

446

Thermal anomalies indicate preferential flow along faults in unconsolidated sedimentary aquifers  

E-Print Network [OSTI]

Thermal anomalies indicate preferential flow along faults in unconsolidated sedimentary aquifers V in unconsolidated siliciclastic aquifers off-set by normal-faults in the Lower Rhine Embayment, Germany. High plane. Most current models of fault hydrology in unconsolidated sedimentary sequences assume faults

Bense, Victor

447

Geometry and scaling relations of a population of very small rift-related normal faults  

E-Print Network [OSTI]

normal faults within the Solite Quarry of the Dan River rift basin range in length from a few millimetres AND SCALING RELATIONS The small normal faults are present in quarries of the Virginia Solite Corporation outcrops and quarried boulders (Fig. 2). The fault traces are typically straight, although the fault tips

448

MICRO-SEISMICITY, FAULT STRUCTURE AND HYDRAULIC COMPARTMENTALIZATION WITHIN  

Open Energy Info (EERE)

MICRO-SEISMICITY, FAULT STRUCTURE AND HYDRAULIC COMPARTMENTALIZATION WITHIN MICRO-SEISMICITY, FAULT STRUCTURE AND HYDRAULIC COMPARTMENTALIZATION WITHIN THE COSO GETHERMAL FIELD, CALIFORNIA Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: MICRO-SEISMICITY, FAULT STRUCTURE AND HYDRAULIC COMPARTMENTALIZATION WITHIN THE COSO GETHERMAL FIELD, CALIFORNIA Details Activities (1) Areas (1) Regions (0) Abstract: High precision earthquake locations and subsurface velocity structure provide potential insights into fracture system geometry, fluid conduits and fluid compartmentalization critical to geothermal reservoir management. We analyze 16 years of seismicity to improve hypocentral locations and simultaneously invert for the seismic velocity structure within the Coso Geothermal Field (CGF). The CGF has been continuously

449

Visualization of stacking faults in fcc crystals in plastic deformations  

E-Print Network [OSTI]

Using molecular dynamics simulation, we investigate the dynamics of stacking faults in fcc crystals in uniaxial stretching in a Lennard-Jones binary mixture composed of 4096 particles in three dimensions. We visualize stacking faults using a disorder variable $D_j(t)$ for each particle $j$ constructed from local bond order parameters based on spherical harmonics (Steinhardt order parameters). Also introducing a method of bond breakage, we examine how stacking faults are formed and removed by collective particle motions. These processes are relevant in plasticity of fcc crystals.

Takeshi Kawasaki; Akira Onuki

2011-11-27T23:59:59.000Z

450

Superconducting fault current limiter for power utility application  

SciTech Connect (OSTI)

Recent accomplishments in the development of superconducting fault current limiters for power systems are outlined. These accomplishments include the comprehensive requirement for fault current limiters developed by SCE; down-selection; bridge concepts; shunt concepts; and high resistivity matrix substrates for HTS conductors. The proposed Phase II SPI-FCL Program is outlined. It is concluded that the SPI fault current limiter program will benefit both the power utility industry as well as the high temperature superconductivity community and progress of Phase I is right on target.

Leung, E. [Martin Marietta Corp., Oak Ridge, TN (United States)

1994-07-29T23:59:59.000Z

451

Fault-tree construction and calculations on a microcomputer  

E-Print Network [OSTI]

Figure 17 - Program Overview Screen Figure 18 ? Main Menu Screen Figure 19 ? Invalid Command Screen Figure 20 - First Usage of Disk Screen Figure 21 ? Fault-tree Name Screen Figure 22 - Invalid Fault-tree Name Screen Fi gure 23 ? TOP EVENT Label... to do? Fi gure 19. Inval i d Command Screen 53 CREATE - This command allows the user to build a new fault tree. After a CREATE command is entered, the system wi 1 1 display the screen in Figure 20. This question is asked in order to determine...

Beckmann, Jeffery Linn

1985-01-01T23:59:59.000Z

452

Climate Zone 5A | Open Energy Information  

Open Energy Info (EERE)

Zone 5A Zone 5A Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 5 and Climate Zone Subtype A. Climate Zone 5A is defined as Cool- Humid with IP Units 5400 < HDD65ºF ≤ 7200 and SI Units 3000 < HDD18ºC ≤ 4000 . The following places are categorized as class 5A climate zones: Adair County, Iowa Adair County, Missouri Adams County, Illinois Adams County, Indiana Adams County, Iowa Adams County, Nebraska Adams County, Pennsylvania Albany County, New York Allegan County, Michigan Alleghany County, North Carolina Allegheny County, Pennsylvania Allen County, Indiana Allen County, Ohio Andrew County, Missouri Antelope County, Nebraska Appanoose County, Iowa Armstrong County, Pennsylvania Arthur County, Nebraska

453

Climate Zone 5B | Open Energy Information  

Open Energy Info (EERE)

Climate Zone 5B Climate Zone 5B Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 5 and Climate Zone Subtype B. Climate Zone 5B is defined as Dry with IP Units 5400 < HDD65ºF ≤ 7200 and SI Units 3000 < HDD18ºC ≤ 4000 . The following places are categorized as class 5B climate zones: Ada County, Idaho Adams County, Colorado Adams County, Washington Apache County, Arizona Arapahoe County, Colorado Asotin County, Washington Baker County, Oregon Beaver County, Utah Benewah County, Idaho Bent County, Colorado Benton County, Washington Boulder County, Colorado Broomfield County, Colorado Canyon County, Idaho Carson City County, Nevada Cassia County, Idaho Catron County, New Mexico Chelan County, Washington Cheyenne County, Colorado

454

Climate Zone Number 1 | Open Energy Information  

Open Energy Info (EERE)

Climate Zone Number 1 Climate Zone Number 1 Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard. Climate Zone Number 1 is defined as Very Hot - Humid(1A) with IP Units 9000 < CDD50ºF and SI Units 5000 < CDD10ºC Dry(1B) with IP Units 9000 < CDD50ºF and SI Units 5000 < CDD10ºC . The following places are categorized as class 1 climate zones: Broward County, Florida Hawaii County, Hawaii Honolulu County, Hawaii Kalawao County, Hawaii Kauai County, Hawaii Maui County, Hawaii Miami-Dade County, Florida Monroe County, Florida Retrieved from "http://en.openei.org/w/index.php?title=Climate_Zone_Number_1&oldid=21604" Category: ASHRAE Climate Zones What links here Related changes Special pages Printable version Permanent link Browse properties

455

Climate Zone 2A | Open Energy Information  

Open Energy Info (EERE)

Climate Zone 2A Climate Zone 2A Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 2 and Climate Zone Subtype A. Climate Zone 2A is defined as Hot - Humid with IP Units 6300 < CDD50ºF ≤ 9000 and SI Units 3500 < CDD10ºC ≤ 5000 . The following places are categorized as class 2A climate zones: Acadia Parish, Louisiana Alachua County, Florida Allen Parish, Louisiana Anderson County, Texas Angelina County, Texas Appling County, Georgia Aransas County, Texas Ascension Parish, Louisiana Assumption Parish, Louisiana Atascosa County, Texas Atkinson County, Georgia Austin County, Texas Avoyelles Parish, Louisiana Bacon County, Georgia Baker County, Florida Baker County, Georgia Baldwin County, Alabama Bastrop County, Texas

456

Enterprise Zone Program (Texas) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Enterprise Zone Program (Texas) Enterprise Zone Program (Texas) Enterprise Zone Program (Texas) < Back Eligibility Commercial Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Texas Program Type Corporate Tax Incentive Enterprise Zone Provider Texas Wide Open for Business The Enterprise Zone Program eligible projects to apply for state sales and use tax refunds on purchases of all taxable items purchased for use at qualified business sites related to the project or activity. The level and amount of refund is related to the capital investment and jobs created at the qualified business site. In addition, local communities must offer incentives to participants under the enterprise zone program, such as tax

457

Climate Zone 3B | Open Energy Information  

Open Energy Info (EERE)

Climate Zone 3B Climate Zone 3B Jump to: navigation, search A type of climate defined in the ASHRAE 169-2006 standard consisting of Climate Zone Number 3 and Climate Zone Subtype B. Climate Zone 3B is defined as Dry with IP Units 4500 < CDD50ºF ≤ 6300 and SI Units 2500 < CDD10ºC < 3500 . The following places are categorized as class 3B climate zones: Andrews County, Texas Baylor County, Texas Borden County, Texas Brewster County, Texas Butte County, California Callahan County, Texas Chaves County, New Mexico Childress County, Texas Clark County, Nevada Cochise County, Arizona Coke County, Texas Coleman County, Texas Collingsworth County, Texas Colusa County, California Concho County, Texas Contra Costa County, California Cottle County, Texas Crane County, Texas Crockett County, Texas

458

Coastal Zone Management Act | Open Energy Information  

Open Energy Info (EERE)

Zone Management Act Zone Management Act Jump to: navigation, search Statute Name Coastal Zone Management Act Year 1972 Url [[File:|160px|link=]] Description The Coastal Zone Management Act of 1972 (CZMA; Pub.L. 92-583, 86 Stat. 1280, enacted October 27, 1972, 16 U.S.C. §§ 1451-1464, Chapter 33) is an Act of Congress passed in 1972 to encourage coastal states to develop and implement coastal zone management plans (CZMPs). This act was established as a United States National policy to preserve, protect, develop, and where possible, restore or enhance, the resources of the Nation's coastal zone for this and succeeding generations. References Wikipedia[1] National Oceanic and Atmospheric Administration[2] The U.S. Congress recognized the importance of meeting the challenge of

459

Microsoft Word - P-12711 Cobscook Bay Project EA.doc  

Broader source: Energy.gov (indexed) [DOE]

ENVIRONMENTAL ASSESSMENT ENVIRONMENTAL ASSESSMENT FOR HYDROPOWER PROJECT PILOT LICENSE Cobscook Bay Tidal Energy Project-FERC Project No. 12711-005 (DOE/EA1916) Maine Federal Energy Regulatory Commission Office of Energy Projects Division of Hydropower Licensing 888 First Street, NE Washington, DC 20426 U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Golden Field Office 1617 Cole Boulevard Golden, Colorado 80401 January 2012 i TABLE OF CONTENTS LIST OF FIGURES ............................................................................................................ iv LIST OF TABLES............................................................................................................... v EXECUTIVE SUMMARY ................................................................................................

460

Atmospheric deposition of organochlorine contaminants to Galveston Bay, Texas  

Science Journals Connector (OSTI)

Atmospheric monitoring of \\{PCBs\\} and chlorinated pesticides (e.g., HCHs, chlordanes, and DDTs) in Galveston Bay was conducted at Seabrook, Texas. Air and wet deposition samples were collected from 2 February 1995 and continued through 6 August 1996. Vapor total PCB (tPCB) concentrations in air ranged from 0.21 to 4.78 ng m?3 with a dominance of tri-chlorinated PCBs. Dissolved tPCBs in rain ranged from 0.08 to 3.34 ng l?1, with tetra-chlorinated \\{PCBs\\} predominating. The predominant isomers found in air and rain were ?- and ?-HCH, ?- and ?-chlordanes, 4,4?-DDT, and dieldrin. The concentrations of \\{PCBs\\} and pesticides in the air and rain revealed no clear seasonal trend. Elevated levels of \\{PCBs\\} in the air occurred when temperatures were high and wind came from urban and industrialized areas (S, SW, NW, and W of the site). Concentrations of \\{HCHs\\} were elevated in April, May, and October, perhaps due to local and/or regional applications of ?-HCH (lindane). Other pesticides showed no notable temporal variation. When winds originated from the Gulf of Mexico (southeasterly), lower concentrations of organochlorines were detected in the air. The direct deposition rate (wet+dry) of \\{PCBs\\} to Galveston Bay (6.40 ?g m?2 yr?1) was significantly higher than that of pesticides by a factor of 5–10. The net flux from gas exchange estimated for \\{PCBs\\} was from Galveston Bay water to the atmosphere (78 ?g m?2 yr?1). Gas exchange of \\{PCBs\\} from bay water to the atmosphere was the dominant flux.

June-Soo Park; Terry L Wade; Stephen Sweet

2001-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Tampa Bay Designated as the Newest Clean Cities Coalition  

Office of Energy Efficiency and Renewable Energy (EERE)

This week, Clean Cities welcomed another major partner in the effort to reduce our nation’s dependence on petroleum – the brand-new Tampa Bay Clean Cities Coalition. Through its network of nearly 100 coalitions across the country, the Energy Department’s Clean Cities program brings together stakeholders to increase the use of alternative fuel and advanced technology vehicles, reduce idling, and improve fuel economy.

462

Bailey Bay Hot Springs Geothermal Area | Open Energy Information  

Open Energy Info (EERE)

Bailey Bay Hot Springs Geothermal Area Bailey Bay Hot Springs Geothermal Area Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Geothermal Resource Area: Bailey Bay Hot Springs Geothermal Area Contents 1 Area Overview 2 History and Infrastructure 3 Regulatory and Environmental Issues 4 Exploration History 5 Well Field Description 6 Geology of the Area 7 Geofluid Geochemistry 8 NEPA-Related Analyses (0) 9 Exploration Activities (0) 10 References Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"TERRAIN","zoom":6,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"500px","height":"300px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":55.982,"lon":-131.6622,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

463

Near Fish Bay Geothermal Area | Open Energy Information  

Open Energy Info (EERE)

Near Fish Bay Geothermal Area Near Fish Bay Geothermal Area Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Geothermal Resource Area: Near Fish Bay Geothermal Area Contents 1 Area Overview 2 History and Infrastructure 3 Regulatory and Environmental Issues 4 Exploration History 5 Well Field Description 6 Geology of the Area 7 Geofluid Geochemistry 8 NEPA-Related Analyses (0) 9 Exploration Activities (0) 10 References Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"TERRAIN","zoom":6,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"500px","height":"300px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":57.3509833,"lon":-135.4106696,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

464

Cold Bay Hot Spring Geothermal Area | Open Energy Information  

Open Energy Info (EERE)

Cold Bay Hot Spring Geothermal Area Cold Bay Hot Spring Geothermal Area Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Geothermal Resource Area: Cold Bay Hot Spring Geothermal Area Contents 1 Area Overview 2 History and Infrastructure 3 Regulatory and Environmental Issues 4 Exploration History 5 Well Field Description 6 Geology of the Area 7 Geofluid Geochemistry 8 NEPA-Related Analyses (0) 9 Exploration Activities (0) 10 References Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"TERRAIN","zoom":6,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"500px","height":"300px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":55.2217,"lon":-162.412,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

465

Weighting and Bayes Nets for Rollup of Surveillance Metrics  

SciTech Connect (OSTI)

The LANL IKE team proposes that the surveillance metrics for several data stream that are used to detect the same failure mode be weighted. Similarly, the failure mode metrics are weighted to obtain a subsystem metric. E.g., if there n data streams (nodes 1-n), the failure mode (node 0) metric is obtained as M{sub 0} = w{sub 1}M{sub 1} + {hor_ellipsis} + w{sub n}M{sub n}, where {Sigma}{sub i=1}{sup n} w{sub i} = 1. This proposal has been implemented with Bayes Nets using the Netica/IKE software by specifying an appropriate conditional probability table (CPT). This CPT is calculated using the same form as (1), where the data stream metrics for the true (T) and false (F) states are replaced by 1 and 0, respectively. Then using this CPT, the failure mode metric calculated by Netica/IKE equals (1). This result has two nice features. First, the rollup Bayes nets is doing can be easily explained. Second, because Bayes Nets can implement this rollup using Netica/IKE, then data marshalling (allocating next year's budget) can be studied. A proof that the claim 'failure mode metric calculated by Netica/IKE equals (1)' for n = 2 and n = 3 follows as well as the sketch of a proof by induction for general n.

Henson, Kriste [Los Alamos National Laboratory; Sentz, Kari [Los Alamos National Laboratory; Hamada, Michael [Los Alamos National Laboratory

2012-04-30T23:59:59.000Z

466

Hot Springs Bay Geothermal Area | Open Energy Information  

Open Energy Info (EERE)

Hot Springs Bay Geothermal Area Hot Springs Bay Geothermal Area Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Geothermal Resource Area: Hot Springs Bay Geothermal Area Contents 1 Area Overview 2 History and Infrastructure 3 Regulatory and Environmental Issues 4 Exploration History 5 Well Field Description 6 Geology of the Area 7 Geofluid Geochemistry 8 NEPA-Related Analyses (0) 9 Exploration Activities (0) 10 References Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"TERRAIN","zoom":6,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"500px","height":"300px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":54.166666,"lon":-165.82,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

467

Enterprise Zone Incentives (Florida) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Incentives (Florida) Incentives (Florida) Enterprise Zone Incentives (Florida) < Back Eligibility Agricultural Commercial Fuel Distributor Industrial Retail Supplier Systems Integrator Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Florida Program Type Enterprise Zone Provider Florida Department of Economic Opportunity Enterprise Zone Incentives encourage business growth within certain geographic areas targeted for economic revitalization. Businesses which create jobs within a designated zone are eligible for several tax incentives, including sales and use tax credit, tax refunds for machinery or equipment, sales tax refund for building materials, and a sales tax exemption for electrical energy

468

Streamside Management Zones (Montana) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Streamside Management Zones (Montana) Streamside Management Zones (Montana) Streamside Management Zones (Montana) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Savings Category Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Montana Program Type Environmental Regulations Provider Montana Department of Natural Resources and Conservation This chapter sets streamside management zones as encompassing a strip at

469

A study of activity characteristics and patterns of sailing from Galveston Bay marinas  

E-Print Network [OSTI]

A STUDY OF ACTIVITY CHARACTERISTICS AND PATTERNS OF SAILING FROM GALVESTON BAY MARINAS A Thesis by RICHARD NATHAN JARMAN Submitted to the Graduate College of Texas A&M University in partial fulfillment of the requi. rement for the degree..., this study focused on sailing which originated from marinas located in the Galveston Bay area. Marinas that provide access to Galveston Bay and adjacent coastal waters contain a major concentration of the sailboats berthed in Texas coastal marinas...

Jarman, Richard Nathan

2012-06-07T23:59:59.000Z

470

Charging of the Penglai 9-1 oil field, Bohai Bay basin, China: Functions of the delta on accumulating petroleum  

Science Journals Connector (OSTI)

Abstract The Penglai 9-1 (PL9-1) oil field, which contains China's third largest offshore oil accumulation (in-place reserves greater than 2.28 × 108 ton or 1.49 × 109 bbl), was found in shallow reservoirs (700–1700 m, 2297–5577 ft) within the most active fault zone in east China. The PL9-1 field contains two oil-bearing series, the granite intrusions in Mesozoic (Mz) and both the sandstone reservoirs in Neogene Guantao (Ng) and Neogene Minghuazhen (Nm) Formation. The origins of the PL9-1 field, both in terms of source rock intervals and generative kitchens, were determined by analyzing biomarker distributions for 61 source rock samples and 33 oil samples. The Mesozoic granite intrusions, which hold more than 80% of the oil reserves in the field, were charged in the west by oil generated from the third member (Es3) of the Shahejie Formation in the Bodong depression. The Neogene reservoirs of the PL9-1 field were charged in the west by oil generated from the third member (Es3) of the Shahejie Formation in the Bodong depression and in the south by oil generated from the first member (Es1) of the Shahejie Formation in the Miaoxibei depression. Interactive contact between the large fan delta and the mature source rocks residing in the Es3 Formation of the Bodong depression resulted in a high expulsion efficiency from the source rocks and rapid oil accumulation in the PL9-1 field, which probably explains how can this large oil field accumulate and preserve within the largest and most active fault zone in east China.

Jinqiang Tian; Fang Hao; Xinhuai Zhou; Huayao Zou; Lei Lan

2014-01-01T23:59:59.000Z

471

E-Print Network 3.0 - andreyev bay naval Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

at the exact location (inside the bay) where the naval operations take place... . Armstrong, 2004. Prediction of instantaneous currents in San Diego ... Source: Chu, Peter C. -...

472

Object Oriented Safety Analysis of an Extra High Voltage Substation Bay  

Science Journals Connector (OSTI)

Experiences of application of the object oriented approach to safety analysis of an extra high voltage substation bay are presented. As the first step...

Bartosz Nowicki; Janusz Górski

1998-01-01T23:59:59.000Z

473

E-Print Network 3.0 - admiralty bay king Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ryde Drummoyne Parramatta Epping Carlingford Macquarie Homebush Bay Strathfield Sydney Kings Cross... Frenchs Forest Brookvale The Spit Manly Chatswood Lane Cove Watsons...

474

Key Neutrino behavior observed at Daya Bay (The College of William...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

wm.edunewsstories2012key-neutrino-behavior-observed-at-daya-bay-123.php Submitted: Thursday, March 8, 2012 - 12:00am...

475

Comparison of physical characteristics between created and natural estuarine marshes in Galveston Bay, Texas  

Science Journals Connector (OSTI)

Five natural and ten created Spartinaalternifloramarshes in the Lower Galveston BaySystem were compared to determine if there weresignificantly different physical characteristicsassociated with each type of marsh...

Tim P. Delaney; James W. Webb; Thomas J. Minello

2000-10-01T23:59:59.000Z

476

Assessing the Exposure of Fish to a Petroleum Spill in Galveston Bay, Texas  

Science Journals Connector (OSTI)

On July 28, 1990 nearly 700,000 gallons of a petroleum product were spilled in Galveston Bay, Texas. The exposure of fish to polynuclear aromatic...

S. J. McDonald; T. L. Wade; J. M. Brooks…

1991-01-01T23:59:59.000Z

477

Vegetation and sediment characteristics of created and natural Spartina alterniflora marshes in Lower Galveston Bay, Texas.  

E-Print Network [OSTI]

??Five natural and ten created Spartina altemiflora marshes in the Lower Galveston Bay System, Texas, were compared to determine if there were significantly different vegetative… (more)

Albertson, Andrea Kai

2012-01-01T23:59:59.000Z

478

Sediment water exchange of trace metals and nutrients in Galveston Bay, Texas.  

E-Print Network [OSTI]

??The benthic fluxes of several trace metals and nutrients were determined for three stations along the salinity gradient in the Trinity Bay region of Galveston… (more)

Warnken, Kent Wayne

2012-01-01T23:59:59.000Z

479

Evaluation of a Decoupling-Based Fault Detection and Diagnostic Technique - Part I: Field Emulation Evaluation  

E-Print Network [OSTI]

), evaporator fouling (Evapfoul), liquid-line restriction (Llrestr), low refrigerant charge (Reflow), and refrigerant high charge (Refhigh). Except for refrigerant charge and compressor leakage faults for which five fault levels were introduced, four fault... for these tests. The method could detect low refrigerant charge and loss of compressor performance at the lowest levels introduced and all other faults at the second level. All of the faults could be reliably diagnosed before a 5% degradation in capacity...

Li, H.; Braun, J.

2006-01-01T23:59:59.000Z

480

Recency of Faulting and Neotectonic Framework in the Dixie Valley  

Open Energy Info (EERE)

of Faulting and Neotectonic Framework in the Dixie Valley of Faulting and Neotectonic Framework in the Dixie Valley Geothermal Field and Other Geothermal Fields of the Basin and Range Jump to: navigation, search OpenEI Reference LibraryAdd to library Report: Recency of Faulting and Neotectonic Framework in the Dixie Valley Geothermal Field and Other Geothermal Fields of the Basin and Range Abstract We studied the role that earthquake faults play in redistributing stresses within in the earths crust near geothermal fields. The geographic foci of our study were the sites of geothermal plants in Dixie Valley, Beowawe, and Bradys Hot Springs, Nevada. Our initial results show that the past history of earthquakes has redistributed stresses at these 3 sites in a manner to open and maintain fluid pathways critical for geothermal development. The

Note: This page contains sample records for the topic "bay fault zone" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Aksaray And Ecemis Faults - Diapiric Salt Relationships- Relevance To The  

Open Energy Info (EERE)

Aksaray And Ecemis Faults - Diapiric Salt Relationships- Relevance To The Aksaray And Ecemis Faults - Diapiric Salt Relationships- Relevance To The Hydrocarbon Exploration In The Tuz Golu (Salt Lake) Basin, Central Anatolia, Turkey Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Aksaray And Ecemis Faults - Diapiric Salt Relationships- Relevance To The Hydrocarbon Exploration In The Tuz Golu (Salt Lake) Basin, Central Anatolia, Turkey Details Activities (0) Areas (0) Regions (0) Abstract: Due to activitiy of the Aksaray and Ecemis Faults, volcanic intrusion and westward movement of the Anatolian plate, diapiric salt structures were occurred in the Tuz Golu (Salt Lake) basin in central Anatolia, Turkey. With the collisions of the Arabian and Anatolian plates during the late Cretaceous and Miocene times, prominent ophiolitic

482

Recency Of Faulting And Neotechtonic Framework In The Dixie Valley  

Open Energy Info (EERE)

Of Faulting And Neotechtonic Framework In The Dixie Valley Of Faulting And Neotechtonic Framework In The Dixie Valley Geothermal Field And Other Geothermal Fields Of The Basin And Range Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Report: Recency Of Faulting And Neotechtonic Framework In The Dixie Valley Geothermal Field And Other Geothermal Fields Of The Basin And Range Details Activities (6) Areas (3) Regions (0) Abstract: We studied the role that earthquake faults play in redistributing stresses within in the earths crust near geothermal fields. The geographic foci of our study were the sites of geothermal plants in Dixie Valley, Beowawe, and Bradys Hot Springs, Nevada. Our initial results show that the past history of earthquakes has redistributed stresses at these 3 sites in a manner to open and maintain fluid pathways critical for geothermal

483

Understanding Fault Characteristics And Sediment Depth For Geothermal  

Open Energy Info (EERE)

Understanding Fault Characteristics And Sediment Depth For Geothermal Understanding Fault Characteristics And Sediment Depth For Geothermal Exploration Using 3D Gravity Inversion In Walker Valley, Nevada Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Paper: Understanding Fault Characteristics And Sediment Depth For Geothermal Exploration Using 3D Gravity Inversion In Walker Valley, Nevada Details Activities (2) Areas (1) Regions (0) Abstract: The Southern Walker Lake Basin, situated in the Walker Lake structural domain, consists of primarily E-W directed extension along N-NNW striking normal faults. Water well drilling on the eastern slopes of the Wassuk Range, west of the city of Hawthorne, Nevada showed elevated temperatures. Two recent drill holes reaching downhole depths of more than 4000 ft give some insight to the geologic picture, but more information

484

Geophysical investigation of concealed faults near Yucca Mountain, southwest Nevada  

SciTech Connect (OSTI)

Detailed gravity and ground magnetic data collected along surveyed traverses across Midway Valley, on the eastern flank of Yucca Mountain, Nevada reveal that these methods can be used to delineate concealed faults. These studies are part of an effort to evaluate faulting in the vicinity of the proposed surface facilities for a potential nuclear waste repository at Yucca Mountain. The largest gravity and magnetic anomaly in the vicinity of Midway Valley is associated with the Paintbrush fault on the west flank of Alice Ridge. Geophysical data infer a vertical offset of about 200 m (650 ft). Another prominent gravity and magnetic anomaly is associated with the Bow Ridge fault in the western part of Midway Valley.

Ponce, D.A. [Geological Survey, Menlo Park, CA (United States)

1993-12-31T23:59:59.000Z

485

Unknown Input Observers and Fault Tolerant Control Allocation Andrea Cristofaro  

E-Print Network [OSTI]

objectives [3] [13] [17] , such as power or fuel consumption minimization. On the other hand, usually in order to make relevant faults observable. The case study of an overactuated marine vessel supports

Johansen, Tor Arne

486

CAPRI: A Common Architecture for Distributed Probabilistic Internet Fault Diagnosis  

E-Print Network [OSTI]

This thesis presents a new approach to root cause localization and fault diagnosis in the Internet based on a Common Architecture for Probabilistic Reasoning in the Internet (CAPRI) in which distributed, heterogeneous ...

Lee, George J.

2007-06-04T23:59:59.000Z

487

CAPRI : a common architecture for distributed probabilistic Internet fault diagnosis  

E-Print Network [OSTI]

This thesis presents a new approach to root cause localization and fault diagnosis in the Internet based on a Common Architecture for Probabilistic Reasoning in the Internet (CAPRI) in which distributed, heterogeneous ...

Lee, George J. (George Janbing), 1979-

2007-01-01T23:59:59.000Z

488

Fault current limiter based on triggered vacuum switch  

Science Journals Connector (OSTI)

A new type of fault current limiter (FCL) based on triggered vacuum switch ... is mainly composed of a capacitor, a current-limiting reactor connected with a capacitor in ... behaves as a conventional series comp...

Jing Shi; Ji-yan Zou; Jun-jia He…

2000-12-01T23:59:59.000Z

489

Coil and HTS Development for Fault Current Limiters  

Science Journals Connector (OSTI)

Fault current limiters are being developed to limit peak currents in transmission and distribution systems. The authors ... and a coil configuration specifically for high transient currents and the resulting high...

B. Gamble; G. Snitchler; M. Manlief…

1997-01-01T23:59:59.000Z

490

Melt-processed YBCO for a Fault Current Limiter  

Science Journals Connector (OSTI)

Bulk High-Tc...-Superconductors (HTSC) offer applications in the field of fault current limiters in power networks: Current limitation can be accomplished by means of ... with a primary winding carrying the power...

H. Kanbach; E. Bochenek; M. Trautmann; R. Fischer…

1994-01-01T23:59:59.000Z

491

Understanding Fault Characteristics And Sediment Depth For Geothermal...  

Open Energy Info (EERE)

Fault Characteristics And Sediment Depth For Geothermal Exploration Using 3D Gravity Inversion In Walker Valley, Nevada Jump to: navigation, search OpenEI Reference LibraryAdd to...

492

Characteristics of Wind Turbines Under Normal and Fault Conditions: Preprint  

SciTech Connect (OSTI)

This paper investigates the characteristics of a variable-speed wind turbine connected to a stiff or weak grid under normal and fault conditions and the role of reactive power compensation.

Muljadi, E.; Butterfield, C. P.; Parsons, B.; Ellis, A.

2007-02-01T23:59:59.000Z

493

Lossless fault-tolerant data structures with additive overhead  

E-Print Network [OSTI]

We develop the first dynamic data structures that tolerate ? memory faults, lose no data, and incur only an O(? ) additive overhead in overall space and time per operation. We obtain such data structures for arrays, linked ...

Christiano, Paul F.

494

8 - Superconducting fault current limiters and power cables  

Science Journals Connector (OSTI)

Abstract: This chapter addresses the technology of superconducting power cables and superconducting fault current limiters. The first part of the chapter is a general summary of the electric power grid. This sets the stage for a discussion of the historical development of superconducting AC and DC cables, which begins with low temperature superconductor-based systems. It then describes the present state of superconducting cable technology and gives a summary of some of the major programs around the world. Whereas power cables may be thought of as a replacement for conventional power system components, fault current limiters and fault current controllers have no conventional equivalent in the power grid. Several conceptually different fault current limiter designs are described. Their state of development and installation on the power grid are described.

W. Hassenzahl

2012-01-01T23:59:59.000Z

495

Performance analysis of fault-tolerant nanoelectronic memories  

E-Print Network [OSTI]

important that defect and fault-tolerant schemes be incorporated into the design of nanotechnology related devices. In this dissertation, we focus on the study of a novel and promising class of computer chip memories called crossbar molecular switch memories...

Coker, Ayodeji

2009-05-15T23:59:59.000Z

496

Detecting and Tolerating Byzantine Faults in Database Systems  

E-Print Network [OSTI]

This thesis describes the design, implementation, and evaluation of a replication scheme to handle Byzantine faults in transaction processing database systems. The scheme compares answers from queries and updates on multiple ...

Vandiver, Benjamin Mead

2008-06-30T23:59:59.000Z

497

Detecting and tolerating Byzantine faults in database systems  

E-Print Network [OSTI]

This thesis describes the design, implementation, and evaluation of a replication scheme to handle Byzantine faults in transaction processing database systems. The scheme compares answers from queries and updates on multiple ...

Vandiver, Benjamin Mead, 1978-

2008-01-01T23:59:59.000Z

498

A fault detection service for wide area distributed computations.  

SciTech Connect (OSTI)

The potential for faults in distributed computing systems is a significant complicating factor for application developers. While a variety of techniques exist for detecting and correcting faults, the implementation of these techniques in a particular context can be difficult. Hence, we propose a fault detection service designed to be incorporated, in a modular fashion, into distributed computing systems, tools, or applications. This service uses well-known techniques based on unreliable fault detectors to detect and report component failure, while allowing the user to tradeoff timeliness of reporting against false positive rates. We describe the architecture of this service, report on experimental results that quantify its cost and accuracy, and describe its use in two applications, monitoring the status of system components of the GUSTO computational grid testbed and as part of the NetSolve network-enabled numerical solver.

Stelling, P.

1998-06-09T23:59:59.000Z

499

A Fault Detection and Diagnosis Method for HVAC Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

A Fault Detection and Diagnosis Method for HVAC Systems A Fault Detection and Diagnosis Method for HVAC Systems Speaker(s): Peng Xu Date: December 2, 2002 - 12:00pm Location: Bldg. 90 There is a growing consensus that most buildings do not perform as well as intended and that faults in HVAC systems are widespread in commercial buildings. An automated fault detection and diagnosis tool for HVAC systems is being developed, based on an integrated, life-cycle, approach to commissioning and performance monitoring. The tool uses component-level HVAC equipment models implemented in the SPARK equation-based simulation environment. The models are configured using design information and component manufacturers' data and then fine-tuned to match the actual performance of the equipment by using data measured during functional tests

500

Fault Mapping At Coso Geothermal Area (1980) | Open Energy Information  

Open Energy Info (EERE)

Fault Mapping At Coso Geothermal Area (1980) Fault Mapping At Coso Geothermal Area (1980) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Fault Mapping At Coso Geothermal Area (1980) Exploration Activity Details Location Coso Geothermal Area Exploration Technique Fault Mapping Activity Date 1980 Usefulness useful DOE-funding Unknown Exploration Basis To determine the Late Cenozoic volcanism, geochronology, and structure of the Coso Range Notes This system apparently is heated by a reservoir of silicic magma at greater than or equal to 8-km depth, itself produced and sustained through partial melting of crustal rocks by thermal energy contained in mantle-derived basaltic magma that intrudes the crust in repsonse to lithospheric extension. References Duffield, W.A.; Bacon, C.R.; Dalrymple, G.B. (10 May 1980) Late