National Library of Energy BETA

Sample records for base load generating

  1. Public Service Commission Authorization to Utilize an Alternative Method of Cost Recovery for Certain Base Load Generation (Mississippi)

    Broader source: Energy.gov [DOE]

    The Senate Bill 2793 authorizes the Public Service Commission (PSC) to utilize an alternative cost recovery for certain base load generation. The PSC is authorized to include in an electric...

  2. Micro-grid operation of inverter based distributed generation with voltage and frequency dependent loads

    E-Print Network [OSTI]

    Zeineldin, H. H.

    Distribution systems are experiencing increasing penetration of distributed generation (DG). One attractive option is to use the available DG capacity during utility outages by forming planned micro-grids. Load sharing ...

  3. Generator Response to Load Variation The below table summarizes the way that load variation is

    E-Print Network [OSTI]

    McCalley, James D.

    1 Generator Response to Load Variation The below table summarizes the way that load variation is allocated to generators in a power system. In these notes, we derive the proximity effect, the inertial, constant impedance loads, and the network reduced to generator internal nodes. This expression was: { }00

  4. Ancillary-service details: regulation, load following, and generator response

    SciTech Connect (OSTI)

    Hirst, E.; Kirby, B.

    1996-09-01

    The purpose of this report is to examine empirically these intrahour and interhour load changes and the responses of a utility`s generating resources to those load changes. We analyze data, primarily from one control area, to see how it maintains ACE close to zero in an effort to meet the A1 and A2 criteria. Overall, we estimate that load following costs US electric utilities over one billion dollars a year. We first test alternative ways to identify trends over multihour periods using both regression analysis and rolling averages. Then, we consider several metrics for intrahour load following. Next we examine characteristics of load following for different time-averaging periods and compare the dynamics of loads and load following generation across these time periods. Finally, we consider the contribution of each load to the total load following requirements of the control area.

  5. Sandia's research spans generation, storage, and load management at

    E-Print Network [OSTI]

    kW diesel genset, fuel cells, and additional interchangeable generators. Storage capabilities technology integration, microgrid communications, enhanced efficiency, load control, and specialized tests

  6. Coupling Wind Generation with Controllable Load and Storage

    E-Print Network [OSTI]

    Electric Energy System #12;Coupling Wind Generation with Controllable Load and Storage: A Time the electric power industry and educating the next generation of power engineers. More information about PSERC will fundamentally alter the traditional generation technology mix. This will place a greater value on technologies

  7. Cost Bases for Incentive Rates Applicable to Industrial Loads 

    E-Print Network [OSTI]

    Stover, C. N.

    1987-01-01

    ; they involve a depressed economy base in all or certain segments of the service area, a decrease in load, excess generation capacity, and an increase in base rates. An increase in rates may also be related to the commercial operation of a base load unit, i... utility has completely abandoned a pricing structure that is in any way related to cost. Some of the incentive rates are very short lived and reflect transient economic conditions while others tend to reflect long-term economic relationships...

  8. The Development of a Small Engine Based Accelerated Ash Loading...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Accelerated Ash Loading Protocol The Development of a Small Engine Based Accelerated Ash Loading Protocol Presentation given at DEER 2006, August 20-24, 2006, Detroit, Michigan....

  9. "Load Management Systems for Component-based Middleware"

    E-Print Network [OSTI]

    Murphy, John

    "Load Management Systems for Component-based Middleware" Octavian Ciuhandu, B.E. Masters Management Services Characteristics . . . . . 26 3.3.2 Load Management Services Classification . . . . . . 28 3.3.3 Load Management Services Requirements . . . . . 30 3.3.4 Load Management Services Components

  10. INVESTING IN NEW BASE LOAD GENERATING CAPACITY

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet) Wyoming Dry NaturalPrices1Markets See full Hydrocarbon Gas2 II NowIII IIUI

  11. Wear-based aspherics generator based on a novel elliptical rotator

    E-Print Network [OSTI]

    Wear-based aspherics generator based on a novel elliptical rotator Oliver W. Fa¨hnle TNO Institute-copying method, it is possible to generate different types of surfaces with the same machining tool. Load for the generation of on- and off-axis surfaces with conic sections as generators (``conic surfaces''). We present

  12. Real-Time Deferrable Load Control: Handling the Uncertainties of Renewable Generation

    E-Print Network [OSTI]

    Low, Steven H.

    Real-Time Deferrable Load Control: Handling the Uncertainties of Renewable Generation Lingwen Gan to handle the un- certainties of renewable generation. It is expected that a large number of deferrable for the random fluctuations in renewable generation. Work on deferrable load control falls into two categories

  13. Distributed Load Demand Scheduling in Smart Grid to Minimize Electricity Generation Cost

    E-Print Network [OSTI]

    Pedram, Massoud

    Distributed Load Demand Scheduling in Smart Grid to Minimize Electricity Generation Cost Siyu Yue of electricity consumers is an effective way to alleviate the peak power demand on the elec- tricity grid- ple users cooperate to perform load demand scheduling in order to minimize the electricity generation

  14. Adaptive load control of microgrids with non-dispatchable generation

    E-Print Network [OSTI]

    Brokish, Kevin Martin

    2009-01-01

    Intelligent appliances have a great potential to provide energy storage and load shedding for power grids. Microgrids are simulated with high levels of wind energy penetration. Frequency-adaptive intelligent appliances are ...

  15. Wind Energy Management System EMS Integration Project: Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations

    SciTech Connect (OSTI)

    Makarov, Yuri V.; Huang, Zhenyu; Etingov, Pavel V.; Ma, Jian; Guttromson, Ross T.; Subbarao, Krishnappa; Chakrabarti, Bhujanga B.

    2010-01-01

    The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind and solar power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation), and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and wind/solar forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. To improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique features make this work a significant step forward toward the objective of incorporating of wind, solar, load, and other uncertainties into power system operations. Currently, uncertainties associated with wind and load forecasts, as well as uncertainties associated with random generator outages and unexpected disconnection of supply lines, are not taken into account in power grid operation. Thus, operators have little means to weigh the likelihood and magnitude of upcoming events of power imbalance. In this project, funded by the U.S. Department of Energy (DOE), a framework has been developed for incorporating uncertainties associated with wind and load forecast errors, unpredicted ramps, and forced generation disconnections into the energy management system (EMS) as well as generation dispatch and commitment applications. A new approach to evaluate the uncertainty ranges for the required generation performance envelope including balancing capacity, ramping capability, and ramp duration has been proposed. The approach includes three stages: forecast and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence levels. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis, incorporating all sources of uncertainties of both continuous (wind and load forecast errors) and discrete (forced generator outages and start-up failures) nature. A new method called the “flying brick” technique has been developed to evaluate the look-ahead required generation performance envelope for the worst case scenario within a user-specified confidence level. A self-validation algorithm has been developed to validate the accuracy of the confidence intervals.

  16. Integration of MHD load models with circuit representations the Z generator.

    SciTech Connect (OSTI)

    Jennings, Christopher A.; Ampleford, David J.; Jones, Brent Manley; McBride, Ryan D.; Bailey, James E.; Jones, Michael C.; Gomez, Matthew Robert.; Cuneo, Michael Edward; Nakhleh, Charles; Stygar, William A.; Savage, Mark Edward; Wagoner, Timothy C.; Moore, James K.

    2013-03-01

    MHD models of imploding loads fielded on the Z accelerator are typically driven by reduced or simplified circuit representations of the generator. The performance of many of the imploding loads is critically dependent on the current and power delivered to them, so may be strongly influenced by the generators response to their implosion. Current losses diagnosed in the transmission lines approaching the load are further known to limit the energy delivery, while exhibiting some load dependence. Through comparing the convolute performance of a wide variety of short pulse Z loads we parameterize a convolute loss resistance applicable between different experiments. We incorporate this, and other current loss terms into a transmission line representation of the Z vacuum section. We then apply this model to study the current delivery to a wide variety of wire array and MagLif style liner loads.

  17. A KNOWLEDGE-BASED CODE GENERATOR GENERATOR Christopher W. Fraser %

    E-Print Network [OSTI]

    Fraser, Christopher W.

    A KNOWLEDGE-BASED CODE GENERATOR GENERATOR Christopher W. Fraser % Department of Computer Science a good local code generator for an ALGOL-like language. It is organized as a production system of rules generation of compilers. Automatic generation of some compiler modules is already available; for example

  18. Laser vaporization clusters from metal loaded graphite used for SWNT generation

    E-Print Network [OSTI]

    Maruyama, Shigeo

    Laser vaporization clusters from metal loaded graphite used for SWNT generation Toshikazu Mukaea, The Univ. of Tokyo In order to study the generation mechanism of SWNTs, we have studied metal-carbon binary clusters generated by the laser vaporization of Ni/Co and Ni/Y doped graphite materials used

  19. Real-Time Deferrable Load Control: Handling the Uncertainties of Renewable Generation

    E-Print Network [OSTI]

    Low, Steven H.

    -time so as to ease the incorporation of renewable energy into the grid, and so are recognized as priority deferrable loads in order to compensate for the random fluctuations of renewable energy. However, realizingReal-Time Deferrable Load Control: Handling the Uncertainties of Renewable Generation Lingwen Gan

  20. Real-Time Deferrable Load Control: Handling the Uncertainties of Renewable Generation

    E-Print Network [OSTI]

    Low, Steven H.

    of renewable energy into the grid, and so are recognized as priority areas for the future smart grid by both for the random fluctuations of renewable energy. However, realizing the potential of deferrable loads re- quiresReal-Time Deferrable Load Control: Handling the Uncertainties of Renewable Generation Lingwen Gan

  1. Wind Loads on Ground-Based Telescopes Douglas G. MacMynowskia*

    E-Print Network [OSTI]

    MacMynowski, Douglas G. - MacMynowski, Douglas G.

    distribution of wind disturbances are defined as a function of relevant design parameters, providing Introduction Design studies are underway for the next generation of large ground-based optical telescopes still lead to significant vibration1,2 . Estimates of the wind loads are required early in the design

  2. Optimal distributed power generation under network load constraints

    E-Print Network [OSTI]

    Utrecht, Universiteit

    , small wind turbine or central heating power units) can be inserted into any transmission line, mainly because of the development of novel components for decentral power generation (solar panels, small wind turbines and heat pumps). This gives rise to the question how many units of each type (solar panel

  3. Lifeline-based Global Load Balancing

    SciTech Connect (OSTI)

    Saraswat, Vijay A.; Kambadur, Prabhanjan; Kodali, Sreedhar; Grove, David; Krishnamoorthy, Sriram

    2011-02-12

    On shared-memory systems, Cilk-style work-stealing has been used to effectively parallelize irregular task-graph based applications such as Unbalanced Tree Search (UTS). There are two main difficulties in extending this approach to distributed memory. In the shared memory approach, thieves (nodes without work) constantly attempt to asynchronously steal work from randomly chosen victims until they find work. In distributed memory, thieves cannot autonomously steal work from a victim without disrupting its execution. When work is sparse, this results in performance degradation. In essence, a direct extension of traditional work-stealing to distributed memory violates the work-first principle underlying work-stealing. Further, thieves spend useless CPU cycles attacking victims that have no work, resulting in system inefficiencies in multi-programmed contexts. Second, it is non-trivial to detect active distributed termination (detect that programs at all nodes are looking for work, hence there is no work). This problem is well-studied and requires careful design for good performance. Unfortunately, in most existing languages/frameworks, application developers are forced to implement their own distributed termination detection. In this paper, we develop a simple set of ideas that allow work-stealing to be efficiently extended to distributed memory. First, we introduce lifeline graphs: low-degree, low diameter, fully connected directed graphs. Such graphs can be constructed from k-dimensional hypercubes. When a node is unable to find work after w unsuccessful steals, it quiesces after informing the outgoing edges in its lifeline graph. Quiescent nodes do not disturb other nodes. A quiesced node is reactivated when work arrives from a lifeline and itself shares this work with those of its incoming lifelines that are activated. Termination occurs precisely when computation at all nodes has quiesced. In a language such as X10, such passive distributed termination can be detected automatically using the finish construct -- no application code is necessary.

  4. ELECTRICAL LOAD MANAGEMENT FOR THE CALIFORNIA WATER SYSTEM

    E-Print Network [OSTI]

    Krieg, B.

    2010-01-01

    Water Projects Generating Plants and Shiftable Generationfrom "base load" generating plants. ing" and saves energy.Cily flow PUfflj);ng - GeneratIng Plant San LUIS Reservo,,'

  5. Load-shedding probabilities with hybrid renewable power generation and energy storage

    E-Print Network [OSTI]

    Xu , Huan

    Load-shedding probabilities with hybrid renewable power generation and energy storage Huan Xu, Ufuk to the intermittency in the power output. These difficulties can be alleviated by effectively utilizing energy storage turbines, supplemented with energy storage. We use a simple storage model alongside a combination

  6. Load-shedding probabilities with hybrid renewable power generation and energy storage

    E-Print Network [OSTI]

    Xu, Huan

    Load-shedding probabilities with hybrid renewable power generation and energy storage Huan Xu, Ufuk, and energy storage. costs [7], [8], [9]. Reference [10] uses a probabilistic model to predict the feasibility Topcu, Steven H. Low, Christopher R. Clarke, and K. Mani Chandy Abstract-- The integration of renewable

  7. Stochastic Weather Generator Based Ensemble Streamflow Forecasting

    E-Print Network [OSTI]

    Stochastic Weather Generator Based Ensemble Streamflow Forecasting by Nina Marie Caraway B of Civil Engineering 2012 #12;This thesis entitled: Stochastic Weather Generator Based Ensemble Streamflow mentioned discipline. #12;iii Caraway, Nina Marie (M.S., Civil Engineering) Stochastic Weather Generator

  8. Figure 1. The net load, or power load minus wind and solar generation, for the state of California on March 31.

    E-Print Network [OSTI]

    Nehorai, Arye

    increase in solar and wind installations. This graph, often called a "Duck Curve" in the industry because can have. When a power grid has a large #12;2 amount of solar power capacity, the middle of this curve1 Figure 1. The net load, or power load minus wind and solar generation, for the state

  9. Distributedfeedback pulse generator based on nonlinearfibre grating

    E-Print Network [OSTI]

    Sipe,J. E.

    Distributedfeedback pulse generator based on nonlinearfibre grating B.J. Eggleton, C.M. de Sterke pulse generator or reshaper with applications in all-optical communications. Introduction: Fibre. This could form the basis of a pulse reshaper or pulse generator device with applications in future all

  10. A LASER-BASED MONODISPERSE CARBON FIBER GENERATOR

    E-Print Network [OSTI]

    Loo, Billy W.

    2013-01-01

    BASED MONODISPERSE CARBON FIBER GENERATOR Billy W. Loo,BASED MONODISPERSE CARBON FIBER GENERATOR Billy W. Loo,BASED MONODISPERSE CARBON FIBER GENERATOR Billy W. Loo,

  11. Cascading Failure Risk Variation with Generator Dispatch and System Load Level

    E-Print Network [OSTI]

    Rezaei, Pooya

    2013-01-01

    Industry reliability rules increasingly require utilities to study and mitigate cascading failure risk in their system. Motivated by this, this paper describes how cascading failure risk, in terms of expected blackout size, varies with power system load level and pre-contingency dispatch. We used Monte Carlo sampling of random branch outages to model contingencies, and a model of cascading failure to estimate blackout sizes. The risk associated with different blackout sizes is separately estimated in order to separate small, medium, and large blackout risk. Results from N-1 secure models of the IEEE RTS case and a 2383 bus case indicate that blackout risk does not always increase with load level, particularly for large blackout risk. The results also show that risk is highly dependent on the method used for generator dispatch. Minimum cost methods of dispatch can result in larger long distance power transfers, which can increase cascading failure risk.

  12. Distributed Internet-based Load Altering Attacks against Smart Power Grids

    E-Print Network [OSTI]

    Mohsenian-Rad, Hamed

    management, cost-efficient load protection. I. INTRODUCTION The recent advancements in smart grid systemsDistributed Internet-based Load Altering Attacks against Smart Power Grids Amir-Hamed Mohsenian distribution system. Keywords: Smart grid security, Internet-based load altering attacks, demand side

  13. A Technique to Utilize Smart Meter Load Information for Adapting Overcurrent Protection for Radial Distribution Systems with Distributed Generations 

    E-Print Network [OSTI]

    Ituzaro, Fred Agyekum

    2012-07-16

    Smart radial distribution grids will include advanced metering infrastructure (AMI) and significant distributed generators (DGs) connected close to loads. DGs in these radial distribution systems (RDS) introduce bidirectional power flows (BPFs...

  14. A Dynamic Water-filling Method for Real-Time HVAC Load Control Based on Model Predictive

    E-Print Network [OSTI]

    Cai, Lin

    load potential. Existing work, such as [3], usually needs accurate long-term load and renewable energy between the fluctuation of non-renewable power generation and the limited demand response potential at users' side. By changing the elastic load w.r.t. both renewable energy generation and inelastic load

  15. Contract-Based Load Management in Federated Distributed Systems Magdalena Balazinska, Hari Balakrishnan, and Mike Stonebraker

    E-Print Network [OSTI]

    Contract-Based Load Management in Federated Distributed Systems Magdalena Balazinska, Hari://nms.lcs.mit.edu/projects/medusa/ Abstract This paper focuses on load management in loosely- coupled federated distributed systems. We in practice. Our load management mechanism is especially well- suited for distributed stream

  16. VIRTUAL TIME BASED DYNAMIC LOAD MANAGEMENT IN THE TIME WARP OPERATING SYSTEM

    E-Print Network [OSTI]

    California at Los Angeles, University of

    VIRTUAL TIME BASED DYNAMIC LOAD MANAGEMENT IN THE TIME WARP OPERATING SYSTEM Peter L. Reiher Jet on parallel machines. Recently TWOS has been substantially improved by the addition of dynamic load management to processors. Because TWOS uses optimistic synchronization, existing load management theory, which tends

  17. A Modular QoS-enabled Load Management Framework for Component-Based Middleware

    E-Print Network [OSTI]

    Murphy, John

    A Modular QoS-enabled Load Management Framework for Component-Based Middleware Octavian Ciuhandu,murphyj}@eeng.dcu.ie ABSTRACT We present a new QoS-enabled load management framework for component oriented middleware application. Keywords Load, distribution, QoS, platform, middleware, optimization, adaptation, management

  18. ContractBased Load Management in Federated Distributed Systems # Magdalena Balazinska, Hari Balakrishnan, and Mike Stonebraker

    E-Print Network [OSTI]

    Contract­Based Load Management in Federated Distributed Systems # Magdalena Balazinska, Hari://nms.lcs.mit.edu/projects/medusa/ Abstract This paper focuses on load management in loosely­ coupled federated distributed systems. We in practice. Our load management mechanism is especially well­ suited for distributed stream

  19. A Reflective QoS-enabled Load Management Framework for Component-Based Middleware

    E-Print Network [OSTI]

    A Reflective QoS-enabled Load Management Framework for Component-Based Middleware Octavian Ciuhandu,murphyj}@eeng.dcu.ie ABSTRACT A new reflective QoS-enabled load management framework for component oriented middleware in complexity for the load management problem. Adaptive middleware offers the possibility of modifying

  20. Neural network based short-term load forecasting using weather compensation

    SciTech Connect (OSTI)

    Chow, T.W.S.; Leung, C.T. [City Univ. of Hong Kong, Kowloon (Hong Kong). Dept. of Electronic Engineering] [City Univ. of Hong Kong, Kowloon (Hong Kong). Dept. of Electronic Engineering

    1996-11-01

    This paper presents a novel technique for electric load forecasting based on neural weather compensation. The proposed method is a nonlinear generalization of Box and Jenkins approach for nonstationary time-series prediction. A weather compensation neural network is implemented for one-day ahead electric load forecasting. The weather compensation neural network can accurately predict the change of actual electric load consumption from the previous day. The results, based on Hong Kong Island historical load demand, indicate that this methodology is capable of providing a more accurate load forecast with a 0.9% reduction in forecast error.

  1. Power Dispatch and Load Control with Generation Uncertainty Pedram Samadi, Shahab Bahrami, Vincent W.S. Wong, and Robert Schober

    E-Print Network [OSTI]

    Wong, Vincent

    and demand. We formulate an optimization problem to jointly minimize the generation cost and discomfort cost there is no control over the load, our proposed algorithm reduces the generation cost by better matching it possible for inverters, which act as an interface between the photovoltaic (PV) units and the grid

  2. Coal based electric generation comparative technologies report

    SciTech Connect (OSTI)

    Not Available

    1989-10-26

    Ohio Clean Fuels, Inc., (OCF) has licensed technology that involves Co-Processing (Co-Pro) poor grade (high sulfur) coal and residual oil feedstocks to produce clean liquid fuels on a commercial scale. Stone Webster is requested to perform a comparative technologies report for grassroot plants utilizing coal as a base fuel. In the case of Co-Processing technology the plant considered is the nth plant in a series of applications. This report presents the results of an economic comparison of this technology with other power generation technologies that use coal. Technologies evaluated were:Co-Processing integrated with simple cycle combustion turbine generators, (CSC); Co-Processing integrated with combined cycle combustion turbine generators, (CCC); pulverized coal-fired boiler with flue gas desulfurization and steam turbine generator, (PC) and Circulating fluidized bed boiler and steam turbine generator, (CFB). Conceptual designs were developed. Designs were based on approximately equivalent net electrical output for each technology. A base case of 310 MWe net for each technology was established. Sensitivity analyses at other net electrical output sizes varying from 220 MWe's to 1770 MWe's were also performed. 4 figs., 9 tabs.

  3. Session-Based Admission Control: A Mechanism for Peak Load Management

    E-Print Network [OSTI]

    Session-Based Admission Control: A Mechanism for Peak Load Management of Commercial Web Sites Ludmila Cherkasova and Peter Phaal AbstractÐIn this paper, we consider a new, session-based workload function, which adjusts itself accordingly to variations in traffic loads. Index TermsÐSession-based web

  4. An actin-based wave generator organizes cell motility

    E-Print Network [OSTI]

    Weiner, Orion D; Marganski, William A; Wu, Lani F; Altschuler, Steven J; Kirschner, Marc W

    2007-01-01

    9 | e221 Actin-Based Wave Generator Organizes Cell MotilityAn Actin-Based Wave Generator Organizes Cell Motility Orion2007) An actin-based wave generator organizes cell motility.

  5. Demonstrating and Validating a Next Generation Model-Based Controller...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    a Next Generation Model-Based Controller for Fuel Efficient, Low Emissions Diesel Engines Demonstrating and Validating a Next Generation Model-Based Controller for Fuel...

  6. Silicon Nanostructure-based Technology for Next Generation Energy...

    Office of Environmental Management (EM)

    Silicon Nanostructure-based Technology for Next Generation Energy Storage Silicon Nanostructure-based Technology for Next Generation Energy Storage 2013 DOE Hydrogen and Fuel Cells...

  7. Model-Based Transient Calibration Optimization for Next Generation...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Based Transient Calibration Optimization for Next Generation Diesel Engines Model-Based Transient Calibration Optimization for Next Generation Diesel Engines 2005 Diesel Engine...

  8. Life cycle assessment of base-load heat sources for district heating system options

    SciTech Connect (OSTI)

    Ghafghazi, Saeed [University of British Columbia, Vancouver; Sowlati, T. [University of British Columbia, Vancouver; Sokhansanj, Shahabaddine [ORNL; Melin, Staffan [Delta Research Corporation

    2011-03-01

    Purpose There has been an increased interest in utilizing renewable energy sources in district heating systems. District heating systems are centralized systems that provide heat for residential and commercial buildings in a community. While various renewable and conventional energy sources can be used in such systems, many stakeholders are interested in choosing the feasible option with the least environmental impacts. This paper evaluates and compares environmental burdens of alternative energy source options for the base load of a district heating center in Vancouver, British Columbia (BC) using the life cycle assessment method. The considered energy sources include natural gas, wood pellet, sewer heat, and ground heat. Methods The life cycle stages considered in the LCA model cover all stages from fuel production, fuel transmission/transportation, construction, operation, and finally demolition of the district heating system. The impact categories were analyzed based on the IMPACT 2002+ method. Results and discussion On a life-cycle basis, the global warming effect of renewable energy options were at least 200 kgeqCO2 less than that of the natural gas option per MWh of heat produced by the base load system. It was concluded that less than 25% of the upstream global warming impact associated with the wood pellet energy source option was due to transportation activities and about 50% of that was resulted from wood pellet production processes. In comparison with other energy options, the wood pellets option has higher impacts on respiratory of inorganics, terrestrial ecotoxicity, acidification, and nutrification categories. Among renewable options, the global warming impact of heat pump options in the studied case in Vancouver, BC, were lower than the wood pellet option due to BC's low carbon electricity generation profile. Ozone layer depletion and mineral extraction were the highest for the heat pump options due to extensive construction required for these options. Conclusions Natural gas utilization as the primary heat source for district heat production implies environmental complications beyond just the global warming impacts. Diffusing renewable energy sources for generating the base load district heat would reduce human toxicity, ecosystem quality degradation, global warming, and resource depletion compared to the case of natural gas. Reducing fossil fuel dependency in various stages of wood pellet production can remarkably reduce the upstream global warming impact of using wood pellets for district heat generation.

  9. Comparison of the response of two and four-stroke diesel-generator sets to transient loading 

    E-Print Network [OSTI]

    Willett, Kenneth Ray

    1979-01-01

    load1ng. The experimental apparatus necessary to conduct this research cons1sts of: ~ The diesel-generator sets. T hree diesel generator sets of comparable power outputs were chosen. . The instrumentat1on system. Instrumentat1on was developed...- ing the plates into the water by means ot a crank and pulley system. The deeper the plates were immersed the lower the resistance and the greater the load, as can be seen from examination of Kirchhoff's Law and the definition of 3-phase power...

  10. Simulations of Lithium-Based Neutron Coincidence Counter for Gd-Loaded Fuel

    SciTech Connect (OSTI)

    Cowles, Christian C.; Kouzes, Richard T.; Siciliano, Edward R.

    2014-10-31

    The Department of Energy Office of Nuclear Safeguards and Security (NA-241) is supporting the project Lithium-Based Alternative Neutron Detection Technology Coincidence Counting for Gd-loaded Fuels at Pacific Northwest National Laboratory for the development of a lithium-based neutron coincidence counter for nondestructively assaying Gd loaded nuclear fuel. This report provides results from MCNP simulations of a lithium-based coincidence counter for the possible measurement of Gd-loaded nuclear fuel. A comparison of lithium-based simulations and UNCL-II simulations with and without Gd loaded fuel is provided. A lithium-based model, referred to as PLNS3A-R1, showed strong promise for assaying Gd loaded fuel.

  11. Economizer recirculation for low-load stability in heat recovery steam generator

    SciTech Connect (OSTI)

    Cuscino, R.T.; Shade, R.L. Jr.

    1986-04-15

    An economizer system is described for heating feedwater in a heat recovery steam generator which consists of: at least first and second economizer tube planes; each of the economizer tube planes including a plurality of generally parallel tubes; the tubes being generally vertically disposed; each of the economizer tube planes including a top header and a bottom header; all of the plurality of tubes in each economizer tube plane being connected in parallel to their top and bottom headers whereby parallel feedwater flow through the plurality of tubes between the top and bottom headers is enabled; one of the top and bottom headers being an inlet header; a second of the top and bottom headers being an outlet header; a boiler feed pump; the boiler feed pump being effective for applying a flow of feedwater to the inlet header; means for serially interconnecting the economizer tube planes; the means for serially interconnecting including means for flowing the feedwater upward and downward in tubes of alternating ones of the economizer tube planes between the inlet header and the outlet header; means for conveying heated feedwater from the outlet header to a using process; means for recirculating at least a portion of the heated feedwater from the outlet header to an inlet of the boiler feed pump; and the means for recirculating including means for relating the portion to a steam load in the using process whereby an increased flow is produced through all of the economizer tube planes at values of the steam load below a predetermined value and a condition permitting initiation of reverse flow in any of the tubes is substantially reduced.

  12. Transistor-based filter for inhibiting load noise from entering a power supply

    DOE Patents [OSTI]

    Taubman, Matthew S

    2013-07-02

    A transistor-based filter for inhibiting load noise from entering a power supply is disclosed. The filter includes a first transistor having an emitter coupled to a power supply, a collector coupled to a load, and a base. The filter also includes a first capacitor coupled between the base of the first transistor and a ground terminal. The filter further includes an impedance coupled between the base and a node between the collector and the load, or a second transistor and second capacitor. The impedance can be a resistor or an inductor.

  13. Balancing traffic load in path-based multicast communication

    E-Print Network [OSTI]

    Al-Dubai, A.Y.; Ould-Khaoua, M.

    Al-Dubai,A.Y. Ould-Khaoua,M. Mackenzie,L.M. Journal of Future Generation Computer Systems, to appear Elsevier Science

  14. A Comparison of Wind Turbine Load Statistics for Inflow Turbulence Fields based on Conventional

    E-Print Network [OSTI]

    Manuel, Lance

    A Comparison of Wind Turbine Load Statistics for Inflow Turbulence Fields based on Conventional for a utility-scale 5MW wind turbine. Load statistics, spectra, and time-frequency analysis representations utility-scale wind turbines. The present study takes on this question by making use of conventional

  15. Mitigation of Fatigue Loads Using Individual Pitch Control of Wind Turbines Based on FAST

    E-Print Network [OSTI]

    Chen, Zhe

    Mitigation of Fatigue Loads Using Individual Pitch Control of Wind Turbines Based on FAST Yunqian University, China jiz@seu.edu.cn Abstract-With the increase of wind turbine dimension and capacity, the wind turbine structures are subjected to prominent loads and fatigue which would reduce the lifetime of wind

  16. A load shedding scheme for inverter based microgrids

    E-Print Network [OSTI]

    Ojeda, Alejandro P

    2011-01-01

    Over the last decade, penetration of microgrids containing distributed generation (DG) sources has increased in grid distribution systems. This requires the stable operation of microgrids when connected to the distribution ...

  17. An Improved Pseudorandom Generator Based on Hardness of Factoring

    E-Print Network [OSTI]

    International Association for Cryptologic Research (IACR)

    An Improved Pseudorandom Generator Based on Hardness of Factoring Nenad Dediâ??c Boston University@eecs.harvard.edu August 26, 2002 Abstract We present a simple to implement and e#cient pseudorandom generator based base and an exponent shorter than n/2 bits. Our generator is based on results by HÅ¡astad, Schrift

  18. An Improved Pseudorandom Generator Based on Hardness of Factoring

    E-Print Network [OSTI]

    International Association for Cryptologic Research (IACR)

    An Improved Pseudorandom Generator Based on Hardness of Factoring Nenad Dedi´c Boston University@eecs.harvard.edu August 26, 2002 Abstract We present a simple to implement and efficient pseudorandom generator based base and an exponent shorter than n/2 bits. Our generator is based on results by H°astad, Schrift

  19. Generation Following with Thermostatically Controlled Loads via Alternating Direction Method of Multipliers Sharing Algorithm

    E-Print Network [OSTI]

    Burger, Eric M.; Moura, Scott J.

    2015-01-01

    5 minute ahead forecasts of wind and solar generationUsing actual wind and solar generation forecasts, ambientCalifornia ISO Wind and Solar Generation 5-Min Forecasts for

  20. Real-Time Deferrable Load Control: Handling the Uncertainties of Renewable Generation

    E-Print Network [OSTI]

    Wierman, Adam

    , e.g., plug-in electric vehicles, dryers, air conditioners, etc. The penetration of deferrable loads has a root-mean- square error of around 18% of the nameplate capacity look- ing 24 hours ahead [16

  1. Generation Following with Thermostatically Controlled Loads via Alternating Direction Method of Multipliers Sharing Algorithm

    E-Print Network [OSTI]

    Burger, Eric M.; Moura, Scott J.

    2015-01-01

    We present 5-minute wind and solar power forecasts reported6 presents the wind and solar power generation for theimpacts of wind generation on california power systems,”

  2. Fibre optical measuring network based on quasi-distributed amplitude sensors for detecting deformation loads

    SciTech Connect (OSTI)

    Kul'chin, Yurii N; Kolchinskiy, V A; Kamenev, O T; Petrov, Yu S

    2013-02-28

    A new design of a sensitive element for a fibre optical sensor of deformation loads is proposed. A distributed fibre optical measuring network, aimed at determining both the load application point and the load mass, has been developed based on these elements. It is shown that neural network methods of data processing make it possible to combine quasi-distributed amplitude sensors of different types into a unified network. The results of the experimental study of a breadboard of a fibre optical measuring network are reported, which demonstrate successful reconstruction of the trajectory of a moving object (load) with a spatial resolution of 8 cm, as well as the load mass in the range of 1 - 10 kg with a sensitivity of 0.043 kg{sup -1}. (laser optics 2012)

  3. Optimal energy-harvesting cycles for load-driven dielectric generators in plane strain

    E-Print Network [OSTI]

    R. Springhetti; E. Bortot; G. deBotton; M. Gei

    2014-03-13

    The performances of energy harvesting generators based on dielectric elastomers are investigated. The configuration is of a thin dielectric film coated by stretchable electrodes at both sides. The film is first stretched, then charged and subsequently, afterwards it is released, and finally the charge is harvested at a higher electric potential. The amount of energy extracted by this cycle is bounded by the electric breakdown and the ultimate stretch ratio of the film as well as by structural instabilities due to loss of tension. To identify the optimal cycle that complies with these limits we formulate a constraint optimization problem and solve it with a dedicated solver for two typical classes of elastic dielectrics. As anticipated, we find that the performance of the generator depends critically on the ultimate stretch ratio of the film. However, more surprising is our finding of a universal limit on the dielectric strength of the film beyond which the optimal cycle is independent of this parameter. Thus, we reveal that, regardless of how large the dielectric strength of the material is, there is an upper bound on the amount of harvested energy that depends only on the ultimate stretch ratio. We conclude the work with detailed calculations of the optimal cycles for two commercially available elastic dielectrics.

  4. Landscape Automata for Search Based Procedural Content Generation.

    E-Print Network [OSTI]

    Ashlock, Dan

    Landscape Automata for Search Based Procedural Content Generation. Daniel Ashlock and Cameron Mc be used for terrain generation or other procedural content generation. Landscape automata are evolvable idealized landforms and to generate a heightmap with controllable connectivity for agents using the height

  5. An Actin-Based Wave Generator Organizes Cell Motility

    E-Print Network [OSTI]

    Weiner, Orion

    An Actin-Based Wave Generator Organizes Cell Motility Orion D. Weiner1,2* , William A. Marganski3 from the membrane. These reciprocal interactions appear to generate propagated waves of actin. Citation: Weiner OD, Marganski WA, Wu LF, Altschuler SJ, Kirschner MW (2007) An actin-based wave generator

  6. Attacks based on Conditional Correlations against the Nonlinear Filter Generator

    E-Print Network [OSTI]

    International Association for Cryptologic Research (IACR)

    ­based keystream generator which could be used as a basic building block in a synchronous stream cipher system of a keystream generator (i.e. NLFG) in a synchronous secret key encryption and decryption system. 2 #12Attacks based on Conditional Correlations against the Nonlinear Filter Generator Bernhard L

  7. GENERATION OF THESAURUS IN DIFFERENT LANGUAGES A COMPUTER BASED SYSTEM

    E-Print Network [OSTI]

    GENERATION OF THESAURUS IN DIFFERENT LANGUAGES A COMPUTER BASED SYSTEM F J DEVADASON Documentation and Bhattacharyya's POPSI. A computer based system, for generating an information retrieval thesaurus, from as an alphabetical thesaurus. Also, once a thesaurus is generated in one language it is possi- ble to produce

  8. A FIRST PRINCIPLES BASED METHOD FOR THE PREDICTION OF LOADING OVER FIXED AND ROTARY WING GEOMETRIES

    E-Print Network [OSTI]

    A FIRST PRINCIPLES BASED METHOD FOR THE PREDICTION OF LOADING OVER FIXED AND ROTARY WING GEOMETRIES Lakshmi N. Sankar and Mert Berkman School of Aerospace Engineering Georgia Institute of Technology-principles based techniques for the prediction of fixed and rotary wing wake geometry are described

  9. Observation-based test set generation 

    E-Print Network [OSTI]

    Cobb, Jeffrey Lee

    2013-02-22

    When circuits are manufactured, there are unavoidable defects that occur in a small but significant portion of the products. Input test patterns that can detect these defects are uniquely generated for each circuit in advance of their production...

  10. ControlBased Load Shedding in Data Stream Management Systems YiCheng Tu and Sunil Prabhakar

    E-Print Network [OSTI]

    Tu, Yicheng

    Control­Based Load Shedding in Data Stream Management Systems Yi­Cheng Tu and Sunil Prabhakar}@cs.purdue.edu Abstract Load shedding has been widely used in data stream man­ agement systems (DSMSs) as a means strategies in determining the tim­ ing and magnitude of load shedding. In this paper, we argue

  11. Control-Based Load Shedding in Data Stream Management Systems Yi-Cheng Tu and Sunil Prabhakar

    E-Print Network [OSTI]

    Tu, Yicheng

    Control-Based Load Shedding in Data Stream Management Systems Yi-Cheng Tu and Sunil Prabhakar Department of Computer Sciences, Purdue University West Lafayette, IN 47907, USA Abstract Load shedding has the time and magnitude of load shedding. In this paper, we argue that these strategies cannot effectively

  12. Next Generation Bio-Based & Sustainable Chemicals Summit

    Broader source: Energy.gov [DOE]

    The 6th Annual Next Generation Bio-Based & Sustainable Chemicals Summit will be hosted in New Orleans, Louisiana, from February 3–5.

  13. Aalborg Universitet Loss Minimizing Operation of Doubly Fed Induction Generator Based Wind Generation

    E-Print Network [OSTI]

    Hu, Weihao

    performance [1]. Moreover, some grid codes already require wind turbines to provide reactive power ability Wind Generation Systems Considering Reactive Power Provision. In Proceedings of the 40th Annual generator based wind generation systems when providing reactive power. The proposed method achieves its goal

  14. A Comprehension Based Cinematic Generator for Virtual Environments

    E-Print Network [OSTI]

    Young, R. Michael

    A Comprehension Based Cinematic Generator for Virtual Environments Bradley A. Cassell Liquid for generating cinematic shot sequences for virtual environments focus on the low-level problems of cam- era]: Natural Language Processing--Discourse General Terms Cinematic Generation, Narrative, Discourse, Planning

  15. Character String Predicate Based Automatic Software Test Data Generation

    E-Print Network [OSTI]

    Lyu, Michael R.

    Character String Predicate Based Automatic Software Test Data Generation Ruilian Zhao Computer is an important element in programming. A problem that needs further research is how to automatically generate generation of program paths including character string predicates, and the effectiveness of this approach

  16. Attacks based on Conditional Correlations against the Nonlinear Filter Generator

    E-Print Network [OSTI]

    International Association for Cryptologic Research (IACR)

    -based keystream generator which could be used as a basic building block in a synchronous stream cipher system. An example is the use of the nonlinear filter generator as a synchronous secret key encryption and decryption=0 cjst+j Fig. 2. The application of a keystream generator (i.e. NLFG) in a synchronous secret key

  17. Stochastic precipitation generation based on a multivariate autoregression model

    E-Print Network [OSTI]

    Borchers, Brian

    Stochastic precipitation generation based on a multivariate autoregression model Oleg V. Makhnin of stochastic precipitation generation has long been of interest. A good generator should produce time series with statistical properties to match those of the real precipitation. Here, we present a multivariate

  18. A Historical Perspective and Business Model for Load Response Aggregation Based on Priority Service

    E-Print Network [OSTI]

    Oren, Shmuel S.

    A Historical Perspective and Business Model for Load Response Aggregation Based on Priority Service technologies and experiments in the 1980's for implementing demand response. We argue that while new smart grid technologies are cheaper and provide more functionality the barrier to demand response implementation

  19. Wood stove use in the end-use load and consumer assessment program residential base sample

    SciTech Connect (OSTI)

    LeBaron, B.A.

    1988-11-01

    This report examines wood heating in the End-Use Load and Consumer Assessment Program (ELCAP) Residential Base Sample during the 1985/1986 heating season. The goals of this study were to assess the frequency of wood burning in homes having wood burning equipment and to estimate the quantity of electrical space heat displaced by it use. 15 refs., 18 figs., 6 tabs.

  20. Market-Based Coordination of Thermostatically Controlled Loads Part I: A Mechanism Design

    E-Print Network [OSTI]

    Zhang, Wei

    through realistic simulations. Index Terms--Mechanism design, demand response, market- based coordination, thermostatically controlled loads I. INTRODUCTION Demand response has attracted considerable research at- tention and reliability of the future smart grid. A natural way to achieve demand response is through various pricing

  1. Experimental Study on Geocell-Reinforced Recycled Asphalt Pavement (RAP) Bases under Static and Cyclic Loading

    E-Print Network [OSTI]

    Thakur, Jitendra Kumar

    2011-01-13

    .1.2 Standard Proctor compaction curve of subgrade 94 Figure 5.1.3 CBR versus moisture content curve of subgrade 95 Figure 5.2.1 Schematic diagram for the set up of cyclic plate load test 96 Figure 5.2.2 Cyclic loading wave 97 Figure 5.2.3 Geotextile... and coastal protection, airfields, railroads, subgrade improvement, and reinforcement to base courses of road sections etc. since the 1970s. Today, there are many types of geosynthetic products (e.g., geogrid, geotextile, geocell, geomembrane, geonet...

  2. Loading and Regeneration Analysis of a Diesel Particulate Filter with a Radio Frequency-Based Sensor

    SciTech Connect (OSTI)

    Sappok, Alex; Prikhodko, Vitaly Y; Parks, II, James E

    2010-01-01

    Accurate knowledge of diesel particulate filter (DPF) loading is critical for robust and efficient operation of the combined engine-exhaust aftertreatment system. Furthermore, upcoming on-board diagnostics regulations require on-board technologies to evaluate the status of the DPF. This work describes the application of radio frequency (RF) based sensing techniques to accurately measure DPF soot levels and the spatial distribution of the accumulated material. A 1.9L GM turbo diesel engine and a DPF with an RF-sensor were studied. Direct comparisons between the RF measurement and conventional pressure-based methods were made. Further analysis of the particulate matter loading rates was obtained with a mass-based soot emission measurement instrument (TEOM). Comparison with pressure drop measurements show the RF technique is unaffected by exhaust flow variations and exhibits a high degree of sensitivity to DPF soot loading and good dynamic response. Additional computational and experimental work further illustrates the spatial resolution of the RF measurements. Based on the experimental results, the RF technique shows significant promise for improving DPF control enabling optimization of the combined engine-aftertreatment system for improved fuel economy and extended DPF service life.

  3. Hydrogen-or-Fossil-Combustion Nuclear Combined-Cycle Systems for Base- and Peak-Load Electricity Production

    SciTech Connect (OSTI)

    Forsberg, Charles W; Conklin, Jim

    2007-09-01

    A combined-cycle power plant is described that uses (1) heat from a high-temperature nuclear reactor to meet base-load electrical demands and (2) heat from the same high-temperature reactor and burning natural gas, jet fuel, or hydrogen to meet peak-load electrical demands. For base-load electricity production, fresh air is compressed; then flows through a heat exchanger, where it is heated to between 700 and 900 C by heat provided by a high-temperature nuclear reactor via an intermediate heat-transport loop; and finally exits through a high-temperature gas turbine to produce electricity. The hot exhaust from the Brayton-cycle gas turbine is then fed to a heat recovery steam generator that provides steam to a steam turbine for added electrical power production. To meet peak electricity demand, the air is first compressed and then heated with the heat from a high-temperature reactor. Natural gas, jet fuel, or hydrogen is then injected into the hot air in a combustion chamber, combusts, and heats the air to 1300 C-the operating conditions for a standard natural-gas-fired combined-cycle plant. The hot gas then flows through a gas turbine and a heat recovery steam generator before being sent to the exhaust stack. The higher temperatures increase the plant efficiency and power output. If hydrogen is used, it can be produced at night using energy from the nuclear reactor and stored until needed. With hydrogen serving as the auxiliary fuel for peak power production, the electricity output to the electric grid can vary from zero (i.e., when hydrogen is being produced) to the maximum peak power while the nuclear reactor operates at constant load. Because nuclear heat raises air temperatures above the auto-ignition temperatures of the various fuels and powers the air compressor, the power output can be varied rapidly (compared with the capabilities of fossil-fired turbines) to meet spinning reserve requirements and stabilize the electric grid. This combined cycle uses the unique characteristics of high-temperature reactors (T>700 C) to produce electricity for premium electric markets whose demands can not be met by other types of nuclear reactors. It may also make the use of nuclear reactors economically feasible in smaller electrical grids, such as those found in many developing countries. The ability to rapidly vary power output can be used to stabilize electric grid performance-a particularly important need in small electrical grids.

  4. Economic and Emissions Implications of Load-Based, Source-based and First-seller Emissions Trading Programs under California AB32

    E-Print Network [OSTI]

    Chen, Yihsu; Liu, Andrew L.; Hobbs, Benjamin F.

    2008-01-01

    cates in a load-based emissions trading scheme. Technicaland First-seller Emissions Trading Programs under Californiaand First-seller Emissions Trading Programs under California

  5. Estimating functions based on eigenfunctions of the generator.

    E-Print Network [OSTI]

    Sørensen, Michael

    Estimating functions based on eigenfunctions of the generator. Kessler and Sørensen (1999). dX t = b(X t )dt + #(X t )dW t , X 0 = x 0 Generator: The di#erential operator L = 1 2 # 2 (x) d 2 dx 2 + b is by Ito's formula a di#usion process with generator (L Y (f # u -1 ))(y) = (L X f)(u -1 (y

  6. HCCI Load Expansion Opportunities using a Fully Variable HVA Research Engine to Guide Development of a Production Intent Cam-based VVA Engine: The Low Load Limit

    SciTech Connect (OSTI)

    Weall, Adam J [ORNL] [ORNL; Szybist, James P [ORNL] [ORNL; Edwards, Kevin Dean [ORNL] [ORNL; Foster, Matthew [Delphi] [Delphi; Confer, Keith [Delphi] [Delphi; Moore, Wayne [Delphi] [Delphi

    2012-01-01

    While the potential emissions and efficiency benefits of HCCI combustion are well known, realizing the potentials on a production intent engine presents numerous challenges. In this study we focus on identifying challenges and opportunities associated with a production intent cam-based variable valve actuation (VVA) system on a multi-cylinder engine in comparison to a fully flexible, naturally aspirated, hydraulic valve actuation (HVA) system on a single-cylinder engine, with both platforms sharing the same GDI fueling system and engine geometry. The multi-cylinder production intent VVA system uses a 2-step cam technology with wide authority cam phasing, allowing adjustments to be made to the negative valve overlap (NVO) duration but not the valve opening durations. On the single cylinder HVA engine, the valve opening duration and lift are variable in addition to the NVO duration. The content of this paper is limited to the low-medium operating load region at 2000rpm. Using different injection strategies, including the NVO pilot injection approach, the single-cylinder engine is operated over a load range from 160-390 kPa net IMEP at 2000 rpm. Changes to valve opening duration on the single-cylinder HVA engine illustrate opportunities for load expansion and efficiency improvement at certain conditions. For instance, the low load limit can be extended on the HVA engine by reducing breathing and operating closer to a stoichiometric air fuel ratio (AFR) by using valve deactivation. The naturally aspirated engine used here without external EGR confirmed that as operating load increases the emissions of NOx increases due to combustion temperature. NOx emissions are found to be one limitation to the maximum load limitation, the other being high pressure rise rate. It is found that the configuration of the production intent cam-based system represents a good compromise between valve lift and duration in the low to medium load region. Changing the extent of charge motion and breathing via valve deactivation prove beneficial at moderating the pressure rise rate and combustion stability and extending the low load limit at 2000rpm on the HVA engine. It also confirms that strategies using a pilot fuel injection are beneficial at low operating loads but that as operating load is increased, the benefits of multiple injection diminish to the point where a single injection offers the best performance.

  7. HCCI Load Expansion Opportunities Using a Fully Variable HVA Research Engine to Guide Developments of a Production Intent Cam-Based VVA Engine: The Low Load Limit

    SciTech Connect (OSTI)

    Weall, Adam J [ORNL; Szybist, James P [ORNL; Edwards, Kevin Dean [ORNL; Foster, Matthew [Delphi; Confer, Keith [Delphi; Moore, Wayne [Delphi

    2012-01-01

    While the potential emissions and efficiency benefits of HCCI combustion are well known, realizing the potentials on a production intent engine presents numerous challenges. In this study we focus on identifying challenges and opportunities associated with a production intent cam-based variable valve actuation (VVA) system on a multi-cylinder engine in comparison to a fully flexible, naturally aspirated, hydraulic valve actuation (HVA) system on a single-cylinder engine, with both platforms sharing the same GDI fueling system and engine geometry. The multi-cylinder production intent VVA system uses a 2-step cam technology with wide authority cam phasing, allowing adjustments to be made to the negative valve overlap (NVO) duration but not the valve opening durations. On the single cylinder HVA engine, the valve opening duration and lift are variable in addition to the NVO duration. The content of this paper is limited to the low-medium operating load region at 2000rpm. Using different injection strategies, including the NVO pilot injection approach, the single-cylinder engine is operated over a load range from 160-390 kPa net IMEP at 2000 rpm. Changes to valve opening duration on the single-cylinder HVA engine illustrate opportunities for load expansion and efficiency improvement at certain conditions. For instance, the low load limit can be extended on the HVA engine by reducing breathing and operating closer to a stoichiometric air fuel ratio (AFR) by using valve deactivation. The naturally aspirated engine used here without external EGR confirmed that as operating load increases the emissions of NOx increases due to combustion temperature. NOx emissions are found to be one limitation to the maximum load limitation, the other being high pressure rise rate. It is found that the configuration of the production intent cam-based system represents a good compromise between valve lift and duration in the low to medium load region. Changing the extent of charge motion and breathing via valve deactivation prove beneficial at moderating the pressure rise rate and combustion stability and extending the low load limit at 2000rpm on the HVA engine. It also confirms that strategies using a pilot fuel injection are beneficial at low operating loads but that as operating load is increased, the benefits of multiple injection diminish to the point where a single injection offers the best performance.

  8. A DATABASE INTEGRATION SYSTEM BASED ON GLOBAL VIEW GENERATION

    E-Print Network [OSTI]

    Lawrence, Ramon

    A DATABASE INTEGRATION SYSTEM BASED ON GLOBAL VIEW GENERATION Uchang Park Duksung Women: database, integration, view, heterogeneity. Abstract: Database integration is a common and growing challenge with the proliferation of database systems, data warehouses, data marts, and other OLAP systems

  9. Array-Based Hierarchical Mesh Generation in Parallel | Argonne...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Array-Based Hierarchical Mesh Generation in Parallel Event Sponsor: Mathematics and Computing Science Seminar Start Date: Aug 20 2015 - 1:00am BuildingRoom: Building 240Room 4301...

  10. On Assessing the Accuracy of Offshore Wind Turbine Reliability-Based Design Loads from the Environmental Contour Method

    E-Print Network [OSTI]

    Manuel, Lance

    On Assessing the Accuracy of Offshore Wind Turbine Reliability-Based Design Loads from to derive design loads for an active stall-regulated offshore wind turbine. Two different Danish offshore contour method; wind turbine; offshore; reliability. INTRODUCTION Inverse reliability techniques

  11. Automated FMEA based diagnostic symptom generation. Neal Snooke1,

    E-Print Network [OSTI]

    Snooke, Neal

    Automated FMEA based diagnostic symptom generation. Neal Snooke1, , Chris Price Department the model based simulation used to produce an automated Failure Modes and Effect Analysis (FMEA to automate the production of a FMEA report, and the paper also considers the relationship between FMEA

  12. An 8-GW long-pulse generator based on Tesla transformer and pulse forming network

    SciTech Connect (OSTI)

    Su, Jiancang; Zhang, Xibo; Li, Rui; Zhao, Liang Sun, Xu; Wang, Limin; Zeng, Bo; Cheng, Jie; Wang, Ying; Peng, Jianchang; Song, Xiaoxin

    2014-06-15

    A long-pulse generator TPG700L based on a Tesla transformer and a series pulse forming network (PFN) is constructed to generate intense electron beams for the purpose of high power microwave (HPM) generation. The TPG700L mainly consists of a 12-stage PFN, a built-in Tesla transformer in a pulse forming line, a three-electrode gas switch, a transmission line with a trigger, and a load. The Tesla transformer and the compact PFN are the key technologies for the development of the TPG700L. This generator can output electrical pulses with a width as long as 200 ns at a level of 8 GW and a repetition rate of 50 Hz. When used to drive a relative backward wave oscillator for HPM generation, the electrical pulse width is about 100 ns on a voltage level of 520 kV. Factors affecting the pulse waveform of the TPG700L are also discussed. At present, the TPG700L performs well for long-pulse HPM generation in our laboratory.

  13. Estimates for Pu-239 loadings in burial ground culverts based on fast/slow neutron measurements

    SciTech Connect (OSTI)

    Winn, W.G.; Hochel, R.C.; Hofstetter, K.J.; Sigg, R.A.

    1989-08-15

    This report provides guideline estimates for Pu-239 mass loadings in selected burial ground culverts. The relatively high recorded Pu-239 contents of these culverts have been appraised as suspect relative to criticality concerns, because they were assayed only with the solid waste monitor (SWM) per gamma-ray counting. After 1985, subsequent waste was also assayed with the neutron coincidence counter (NCC), and a comparison of the assay methods showed that the NCC generally yielded higher assays than the SWM. These higher NCC readings signaled a need to conduct non-destructive/non-intrusive nuclear interrogations of these culverts, and a technical team conducted scoping measurements to illustrate potential assay methods based on neutron and/or gamma counting. A fast/slow neutron method has been developed to estimate the Pu-239 in the culverts. In addition, loading records include the SWM assays of all Pu-239 cuts of some of the culvert drums and these data are useful in estimating the corresponding NCC drum assays from NCC vs SWM data. Together, these methods yield predictions based on direct measurements and statistical inference.

  14. On Market-Based Coordination of Thermostatically Controlled Loads With User Preference

    SciTech Connect (OSTI)

    Li, Sen; Zhang, Wei; Lian, Jianming; Kalsi, Karanjit

    2014-12-15

    This paper presents a market-based control framework to coordinate a group of autonomous Thermostatically Controlled Loads (TCL) to achieve the system-level objectives with pricing incentives. The problem is formulated as maximizing the social welfare subject to feeder power constraint. It allows the coordinator to affect the aggregated power of a group of dynamical systems, and creates an interactive market where the users and the coordinator cooperatively determine the optimal energy allocation and energy price. The optimal pricing strategy is derived, which maximizes social welfare while respecting the feeder power constraint. The bidding strategy is also designed to compute the optimal price in real time (e.g., every 5 minutes) based on local device information. The coordination framework is validated with realistic simulations in GridLab-D. Extensive simulation results demonstrate that the proposed approach effectively maximizes the social welfare and decreases power congestion at key times.

  15. Generating and Managing Metadata for Web-Based Information Systems

    E-Print Network [OSTI]

    van Harmelen, Frank

    Generating and Managing Metadata for Web-Based Information Systems Heiner Stuckenschmidt and Frank, aggregate and visualize the metadata of an existing information system. We conclude that the possibility by potential users. In this paper we describe a system for the validation of semi-structured information

  16. An improved RNS generator kn 2 based on

    E-Print Network [OSTI]

    Sousa, Leonel

    An improved RNS generator kn ±2 based on threshold logic line 2: name Affiliation (Author) Abstract of the Residue Number System (RNS) offers the potential for high- speed and parallel arithmetic. RNS is a carry systems [1]. RNS has shown significant efficiency in implementing different types of Digital Signal

  17. : A TWO-DIMENSIONAL BATHYMETRY BASED UNSTRUCTURED TRIANGULAR GRID GENERATOR

    E-Print Network [OSTI]

    unstructured triangular grid refinement algorithms, including the recent "off-centers" method, is providedBATTRI* : A TWO-DIMENSIONAL BATHYMETRY BASED UNSTRUCTURED TRIANGULAR GRID GENERATOR FOR FINITE utilities to check and improve grid quality. The final output mesh node locations, node depths and element

  18. Generating Test Cases for XML-based Web Component

    E-Print Network [OSTI]

    Offutt, Jeff

    1 Generating Test Cases for XML-based Web Component Interactions Using Mutation Analysis Suet Chun Offutt George Mason University Fairfax, VA USA www.ise.gmu.edu/faculty/ofut/ © Lee & Offutt 2 Client WebMulti--tiered Web Softwaretiered Web Software SystemsSystems #12;2 © Lee & Offutt 3 Composite Multilateral Web

  19. Dielectric Elastomer Generators for Foot Plantar Pressure Based Energy Scavenging

    E-Print Network [OSTI]

    Potkonjak, Miodrag

    . Dielectric Elastomers (DEs) are now gaining notice as low-cost electrostatic transducers with high energy to a need for high energy-density harvesters. DEs are a promising new class of low-cost materials capableDielectric Elastomer Generators for Foot Plantar Pressure Based Energy Scavenging Vishwa Goudar

  20. Assessment of LWR piping design loading based on plant operating experience

    SciTech Connect (OSTI)

    Svensson, P. O.

    1980-08-01

    The objective of this study has been to: (1) identify current Light Water Reactor (LWR) piping design load parameters, (2) identify significant actual LWR piping loads from plant operating experience, (3) perform a comparison of these two sets of data and determine the significance of any differences, and (4) make an evaluation of the load representation in current LWR piping design practice, in view of plant operating experience with respect to piping behavior and response to loading.

  1. A digital-based excitation system for generator voltage control

    SciTech Connect (OSTI)

    D'Antonio, M.J.; Lawson, R.A.; Pearson, W.R. (General Electric Co., Salem, VA (US)); Speer, G.W. (General Electric Canada, Peterborough, Ontario (CA)); Crenshaw, M.L.; Murdoch, A. (GE Industrial and Power Systems, Power Systems Engineering Dept., Schenectady, NY (US))

    1991-01-01

    Excitation systems have evolved over the years as new technology is introduced, offering easier implementations, higher reliability, less maintenance, enhanced functionality, and user friendly interfaces. Microprocessor based controls are now common in electric drives, protective relaying, turbine controls, power plant displays and supervisory control functions. The flexibility, functionality, and user friendly interface capabilities of digital controls are now available for excitation systems. This paper provides an overview of GE's first generation digital excitation system, SILCO 5, and an introduction to GE's second generation system, EX2000, currently in development.

  2. Systems and methods for providing power to a load based upon a control strategy

    DOE Patents [OSTI]

    Perisic, Milun; Kajouke, Lateef A; Ransom, Ray M

    2013-12-24

    Systems and methods are provided for an electrical system. The electrical system includes a load, an interface configured to receive a voltage from a voltage source, and a controller configured to receive the voltage from the voltage source through the interface and to provide a voltage and current to the load. Wherein, when the controller is in a constant voltage mode, the controller provides a constant voltage to the load, when the controller is in a constant current mode, the controller provides a constant current to the load, and when the controller is in a constant power mode, the controller provides a constant power to the load.

  3. Demonstration of Security Benefits of Renewable Generation at FE Warren Air Force Base

    SciTech Connect (OSTI)

    Warwick, William M.; Myers, Kurt; Seifert, Gary

    2010-12-31

    Report detailing field demonstration of security benefits of renewable generation at FE Warren Air Force Base.

  4. Wind load design methods for ground-based heliostats and parabolic dish collectors

    SciTech Connect (OSTI)

    Peterka, J A; Derickson, R G

    1992-09-01

    The purpose of this design method is to define wind loads on flat heliostat and parabolic dish collectors in a simplified form. Wind loads are defined for both mean and peak loads accounting for the protective influence of upwind collectors, wind protective fences, or other wind-blockage elements. The method used to define wind loads was to generalize wind load data obtained during tests on model collectors, heliostats or parabolic dishes, placed in a modeled atmospheric wind in a boundary-layer wind-tunnel at Colorado State University. For both heliostats and parabolic dishes, loads are reported for solitary collectors and for collectors as elements of a field. All collectors were solid with negligible porosity; thus the effects of porosity in the collectors is not addressed.

  5. A tandem-based compact dual-energy gamma generator

    E-Print Network [OSTI]

    Persaud, A.

    2010-01-01

    The prototype tandem generator has been built using a smallmonoenergetic photon generator. The experiments indicateion source[6]. The tandem generator was designed to be able

  6. Regression Models for Demand Reduction based on Cluster Analysis of Load Profiles

    SciTech Connect (OSTI)

    Yamaguchi, Nobuyuki; Han, Junqiao; Ghatikar, Girish; Piette, Mary Ann; Asano, Hiroshi; Kiliccote, Sila

    2009-06-28

    This paper provides new regression models for demand reduction of Demand Response programs for the purpose of ex ante evaluation of the programs and screening for recruiting customer enrollment into the programs. The proposed regression models employ load sensitivity to outside air temperature and representative load pattern derived from cluster analysis of customer baseline load as explanatory variables. The proposed models examined their performances from the viewpoint of validity of explanatory variables and fitness of regressions, using actual load profile data of Pacific Gas and Electric Company's commercial and industrial customers who participated in the 2008 Critical Peak Pricing program including Manual and Automated Demand Response.

  7. Systems and methods for providing power to a load based upon a control strategy

    SciTech Connect (OSTI)

    Perisic, Milun; Lawrence, Christopher P; Ransom, Ray M; Kajouke, Lateef A

    2014-11-04

    Systems and methods are provided for an electrical system. The electrical system, for example, includes a first load, an interface configured to receive a voltage from a voltage source, and a controller configured to receive the voltage through the interface and to provide a voltage and current to the first load. The controller may be further configured to, receive information on a second load electrically connected to the voltage source, determine an amount of reactive current to return to the voltage source such that a current drawn by the electrical system and the second load from the voltage source is substantially real, and provide the determined reactive current to the voltage source.

  8. High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs

    DOE Patents [OSTI]

    Shimer, D.W.; Lange, A.C.

    1995-05-23

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

  9. High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs

    DOE Patents [OSTI]

    Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

    1995-01-01

    A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

  10. Robust quantum random number generator based on avalanche photodiodes

    E-Print Network [OSTI]

    Fang-Xiang Wang; Chao Wang; Wei Chen; Shuang Wang; Fu-Sheng Lv; De-Yong He; Zhen-Qiang Yin; Hong-Wei Li; Guang-Can Guo; Zheng-Fu Han

    2015-06-18

    We propose and demonstrate a scheme to realize a high-efficiency truly quantum random number generator (RNG) at room temperature (RT). Using an effective extractor with simple time bin encoding method, the avalanche pulses of avalanche photodiode (APD) are converted into high-quality random numbers (RNs) that are robust to slow varying noise such as fluctuations of pulse intensity and temperature. A light source is compatible but not necessary in this scheme. Therefor the robustness of the system is effective enhanced. The random bits generation rate of this proof-of-principle system is 0.69 Mbps with double APDs and 0.34 Mbps with single APD. The results indicate that a high-speed RNG chip based on the scheme is potentially available with an integrable APD array.

  11. Cost-Effectivenessof PhotovoltaicGenerationIn A Transmission-Constrained Load Area of An InterconnectedSystem

    E-Print Network [OSTI]

    Gross, George

    Abstract: Electric power systems of today are experiencing a difficulty of constrained transmission lines, present electric system networks are experiencing the difficulty of constrained transmission lines: Photovoltaic Generation, Power System Economics, Dispersed Generation, Transmission-Constrained Interconnected

  12. A hardware-based approach to adaptive load-sharing on a local area network 

    E-Print Network [OSTI]

    Reddy, Harikrishna M

    1994-01-01

    . This chip also aids a heavily-loaded processor in speeding up the process of finding a lightly-loaded partner on the network. The collisions on the Ethernet can be easily detected at the hardware level and thus by shifting the process of finding a lightly...

  13. Hash-based Proximity Clustering for Load Balancing in Heterogeneous DHT Networks

    E-Print Network [OSTI]

    Xu, Cheng-Zhong

    of their physi- cal proximity information on the Internet. The supernodes form a self-organized and churn and ex- hibits strong resilience to the effect of churn. It also greatly reduces the overhead randomized load balancing algo- rithms for load reassignment in DHTs with churn. The algo- rithms treat all

  14. Quantum Mechanical Energy-Based Screening of Combinatorially Generated Library of Tautomers. TauTGen: A Tautomer Generator Program

    E-Print Network [OSTI]

    Simons, Jack

    Quantum Mechanical Energy-Based Screening of Combinatorially Generated Library of Tautomers. TauTGen: A Tautomer Generator Program Maciej Haran´czyk, and Maciej Gutowski*,,,§ Department of Chemistry, University of finding low-energy tautomers of a molecule. The procedure consists of (i) combinatorial generation

  15. Pseudorandom Generator Based on Hard Lattice Problem This paper studies how to construct a pseudorandom generator using hard lattice prob-

    E-Print Network [OSTI]

    International Association for Cryptologic Research (IACR)

    Pseudorandom Generator Based on Hard Lattice Problem Cheng Kuan Abstract This paper studies how to construct a pseudorandom generator using hard lattice prob- lems. We use a variation of the classical hard the same, we construct a pseudorandom generator using the method in [GKL93]. Also, we construct

  16. Plan generation strategies for a knowledge based process planning system 

    E-Print Network [OSTI]

    Hari, Umesh

    1993-01-01

    by the meta-knowledge entities called as meta-goals, meta-plans and meta-themes. These planning elements are then encapsulated into a plan generation mechanism within the master planner. The planning activity is stratified into four modules based... . 4. I Introduction 4. 2 Planning Mechanism 4. 3 Ontology of Planning Modes 4. 4 Meta-Planning Knowledge 4. 5 Architecture of the Master Planner V IDEFO MODELS OF PROCESS PLANNING ACTIVITIES Page 59 59 59 63 66 68 70 5. I Introduction 5...

  17. DISLOCATION GENERATION IN Si: A THERMO-MECHANICAL MODEL BASED ON MEASURABLE PARAMETERS*

    E-Print Network [OSTI]

    Balzar, Davor

    DISLOCATION GENERATION IN Si: A THERMO-MECHANICAL MODEL BASED ON MEASURABLE PARAMETERS* Bhushan for predicting dislocation distribution generated by thermal stresses in Si is described. We use that can minimize dislocation generation for improved solar cell performance. INTRODUCTION Dislocations

  18. Dynamic load balancing algorithm for molecular dynamics based on Voronoi cells domain decompositions

    SciTech Connect (OSTI)

    Fattebert, J.-L.; Richards, D.F.; Glosli, J.N.

    2012-12-01

    We present a new algorithm for automatic parallel load balancing in classical molecular dynamics. It assumes a spatial domain decomposition of particles into Voronoi cells. It is a gradient method which attempts to minimize a cost function by displacing Voronoi sites associated with each processor/sub-domain along steepest descent directions. Excellent load balance has been obtained for quasi-2D and 3D practical applications, with up to 440·106 particles on 65,536 MPI tasks.

  19. ELEN$4511 POWER$SYSTEMS$ANALYSIS$FINALPROJECT! ! Electric!Vehicles!Charging!Load!Calculations!based!on! !

    E-Print Network [OSTI]

    Lavaei, Javad

    !shifting!role!into!full!play.! ! In!my!project,!starting!from!the!development!status!and!trends!of!electric!vehicles,! analyze!developing!countries'!electric!charging!load!calculation!methods!under!the!charging!mode,!and! calculate!and!analyze!developing!countries'!future!electric!vehicle!charging!load.! ! Also,!in!my!project!the!reliability!and!energy!efficiency!of!power!system,!to! build!the!electric!cars!charging!model,!to!develop!appropriate!charging!strategies! for!users!and!to

  20. Durable pd-based alloy and hydrogen generation membrane thereof

    DOE Patents [OSTI]

    Benn, Raymond C. (Madison, CT); Opalka, Susanne M. (Glastonbury, CT); Vanderspurt, Thomas Henry (Glastonbury, CT)

    2010-02-02

    A durable Pd-based alloy is used for a H.sub.2-selective membrane in a hydrogen generator, as in the fuel processor of a fuel cell plant. The Pd-based alloy includes Cu as a binary element, and further includes "X", where "X" comprises at least one metal from group "M" that is BCC and acts to stabilize the .beta. BCC phase for stability during operating temperatures. The metal from group "M" is selected from the group consisting of Fe, Cr, Nb, Ta, V, Mo, and W, with Nb and Ta being most preferred. "X" may further comprise at least one metal from a group "N" that is non-BCC, preferably FCC, that enhances other properties of the membrane, such as ductility. The metal from group "N" is selected from the group consisting of Ag, Au, Re, Ru, Rh, Y, Ce, Ni, Ir, Pt, Co, La and In. The at. % of Pd in the binary Pd--Cu alloy ranges from about 35 at. % to about 55 at. %, and the at. % of "X" in the higher order alloy, based on said binary alloy, is in the range of about 1 at. % to about 15 at. %. The metals are selected according to a novel process.

  1. Pseudo-random number generator based on asymptotic deterministic randomness

    E-Print Network [OSTI]

    Kai Wang; Wenjiang Pei; Haishan Xia; Yiu-ming Cheung

    2007-10-10

    An approach to generate the pseudorandom-bit sequence from the asymptotic deterministic randomness system is proposed in this Letter. We study the characteristic of multi-value correspondence of the asymptotic deterministic randomness constructed by the piecewise linear map and the noninvertible nonlinearity transform, and then give the discretized systems in the finite digitized state space. The statistic characteristics of the asymptotic deterministic randomness are investigated numerically, such as stationary probability density function and random-like behavior. Furthermore, we analyze the dynamics of the symbolic sequence. Both theoretical and experimental results show that the symbolic sequence of the asymptotic deterministic randomness possesses very good cryptographic properties, which improve the security of chaos based PRBGs and increase the resistance against entropy attacks and symbolic dynamics attacks.

  2. Integration and operation of post-combustion capture system on coal-fired power generation: load following and peak power

    E-Print Network [OSTI]

    Brasington, Robert David, S.M. Massachusetts Institute of Technology

    2012-01-01

    Coal-fired power plants with post combustion capture and sequestration (CCS) systems have a variety of challenges to integrate the steam generation, air quality control, cooling water systems and steam turbine with the ...

  3. Aalborg Universitet Stability Analysis for Isolated AC Microgrids Based on PV-Active Generators

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    Aalborg Universitet Stability Analysis for Isolated AC Microgrids Based on PV-Active Generators for Isolated AC Microgrids Based on PV-Active Generators. In Proceedings of the 2015 IEEE Energy Conversion.aau.dk on: november 29, 2015 #12;Stability Analysis for Isolated AC Microgrids Based on PV-Active Generators

  4. Computer Control for IGBT Based Heat Load System with Rapid Response and Large Heat Flux

    E-Print Network [OSTI]

    Li, Yangmin

    system. So it can acquire the satisfactory performance, what is more, the heat load system combined heat flux within very short time, but it needs a very complicated welding power supply, and meantime, heating coils, etc. There are three power amplifiers: linear amplifier, on-off amplifier, and pulse width

  5. {Control of Residential Load Management Networks Using Real Time Pricing

    E-Print Network [OSTI]

    Burke, William Jerome

    2010-01-01

    modeling and control of load management. Further, withoutA profit-based load management using linear programming”.with applica- tions to load management assessment and load

  6. Physics based model for online fault detection in autonomous cryogenic loading system

    SciTech Connect (OSTI)

    Kashani, Ali; Ponizhovskaya, Ekaterina; Luchinsky, Dmitry; Smelyanskiy, Vadim; Patterson-Hine, Anna; Sass, Jared; Brown, Barbara

    2014-01-29

    We report the progress in the development of the chilldown model for a rapid cryogenic loading system developed at NASA-Kennedy Space Center. The nontrivial characteristic feature of the analyzed chilldown regime is its active control by dump valves. The two-phase flow model of the chilldown is approximated as one-dimensional homogeneous fluid flow with no slip condition for the interphase velocity. The model is built using commercial SINDA/FLUINT software. The results of numerical predictions are in good agreement with the experimental time traces. The obtained results pave the way to the application of the SINDA/FLUINT model as a verification tool for the design and algorithm development required for autonomous loading operation.

  7. Chinese Sentence Generation in a KnowledgeBased Machine Translation System

    E-Print Network [OSTI]

    Spirtes, Peter

    Chinese Sentence Generation in a Knowledge­Based Machine Translation System Tangqiu Li, Eric H presents a technique for generating Chinese sentences from the Interlingua expressions used in the KANT knowledge­based machine translation system. Chinese sentences are generated directly from the semantic

  8. MAD: A Real World Application of Qualitative Model-Based Decision Tree Generation for Diagnosis

    E-Print Network [OSTI]

    Hamburg,.Universität

    equipment. Furthermore, cost of diagnosis system generation, modification and maintenance is reduced. We knowledge and computer-based product data for diagnosis system generation. This way, the cost of diagnosisMAD: A Real World Application of Qualitative Model-Based Decision Tree Generation for Diagnosis

  9. Attacks on a Lightweight Cipher Based on a Multiple Recursive Generator

    E-Print Network [OSTI]

    International Association for Cryptologic Research (IACR)

    Attacks on a Lightweight Cipher Based on a Multiple Recursive Generator Lu Xiao and Gregory G. Rose Abstract At IEEE GLOBECOM 2008, a lightweight cipher based on a Multiple Recursive Generator (MRG plaintext attack is proposed to construct the cipher's current state and generate subkeys used for all

  10. Attacks on a Lightweight Cipher Based on a Multiple Recursive Generator

    E-Print Network [OSTI]

    International Association for Cryptologic Research (IACR)

    Attacks on a Lightweight Cipher Based on a Multiple Recursive Generator Lu Xiao and Gregory G. Rose Abstract At IEEE GLOBECOM 2008, a lightweight cipher based on a Multiple Recursive Generator (MRG attack is proposed to construct the cipher's current state and generate subkeys used for all subsequent

  11. Agent-Based Simulation of Distribution Systems with High Penetration of Photovoltaic Generation

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    1 Agent-Based Simulation of Distribution Systems with High Penetration of Photovoltaic Generation- tems, photovoltaic generation, power distribution, power system economics, smart grids. I. INTRODUCTION study of electric distribution systems with high penetration of photovoltaic (PV) panels within

  12. ANUDlSiTM-40 Load Flow Analysis: Base Cases, Data, Diagrams, and Results

    Office of Scientific and Technical Information (OSTI)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefield Municipal GasAdministrationTechnicalTechnicalScience.govWSRC-MS-g8-00318ANUDlSiTM-40 Load Flow

  13. Improvement of load-following capacity based on the flame radiation intensity signal in a power plant

    SciTech Connect (OSTI)

    Fei Wang; Qunxing Huang; Dong Liu; Jianhua Yan; Kefa Cen [Zhejiang University, Hangzhou (China). State Key Laboratory of Clean Energy Utilization

    2008-05-15

    The capability to perform fast load changes has been an important issue due to the increasing commercialization of the power market. In the traditional boiler control system, the feedback signals come from the variations of the steam pressure and the steam flow, which leads to a large time delay. Therefore, a new method for the boiler control system based on radiation intensity for improving the load-following capacity of a coal-fired power plant has been developed in this paper. The system is implemented by adding the radiation intensity of the flame to the existing boiler control system as a complement. The radiation intensity obtained by the sensor can directly reflect the input heat in the boiler, with a faster response and higher sensitivity. Field tests on a 300 MW coal-fired power plant reveal that the improved boiler control system increases the load-following capacity. At the same time, the steam pressure variations are smaller as compared with those of the existing control system. 14 refs., 19 figs., 1 tab.

  14. Comparison of generality based algorithm variants for automatic taxonomy generation

    E-Print Network [OSTI]

    Madnick, Stuart E.

    We compare a family of algorithms for the automatic generation of taxonomies by adapting the Heymann-algorithm in various ways. The core algorithm determines the generality of terms and iteratively inserts them in a growing ...

  15. Comparison of Generality Based Algorithm Variants for Automatic Taxonomy Generation

    E-Print Network [OSTI]

    Henschel, Andreas

    We compare a family of algorithms for the automatic generation of taxonomies by adapting the Heymannalgorithm in various ways. The core algorithm determines the generality of terms and iteratively inserts them in a growing ...

  16. Load cell

    DOE Patents [OSTI]

    Spletzer, B.L.

    1998-12-15

    A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs, each directly proportional to one of the six general load components. 16 figs.

  17. Applying Model-based Diagnosis to a Rapid Propellant Loading System Charlie Goodrich*. Sriram Narasimhan**, Matthew Daigle**, Walter Hatfield*, Robert Johnson*, Barbara Brown***

    E-Print Network [OSTI]

    Daigle, Matthew

    Applying Model-based Diagnosis to a Rapid Propellant Loading System Charlie Goodrich*. Sriram.h.hatfield@nasa.gov,robert.g.johnson@nasa.gov), **University of California Santa Cruz USA (e-mail:sriram.narasimhan-1@nasa.gov, matthew

  18. Intelligent electrical outlet for collective load control

    DOE Patents [OSTI]

    Lentine, Anthony L.; Ford, Justin R.; Spires, Shannon V.; Goldsmith, Steven Y.

    2015-10-27

    Various technologies described herein pertain to an electrical outlet that autonomously manages loads in a microgrid. The electrical outlet can provide autonomous load control in response to variations in electrical power generation supply in the microgrid. The electrical outlet includes a receptacle, a sensor operably coupled to the receptacle, and an actuator configured to selectively actuate the receptacle. The sensor measures electrical parameters at the receptacle. Further, a processor autonomously controls the actuator based at least in part on the electrical parameters measured at the receptacle, electrical parameters from one or more disparate electrical outlets in the microgrid, and a supply of generated electric power in the microgrid at a given time.

  19. Intelligent electrical outlet for collective load control

    DOE Patents [OSTI]

    Lentine, Anthony L; Ford, Justin R; Spires, Shannon V; Goldsmith, Steven Y

    2015-11-05

    Various technologies described herein pertain to an electrical outlet that autonomously manages loads in a microgrid. The electrical outlet can provide autonomous load control in response to variations in electrical power generation supply in the microgrid. The electrical outlet includes a receptacle, a sensor operably coupled to the receptacle, and an actuator configured to selectively actuate the receptacle. The sensor measures electrical parameters at the receptacle. Further, a processor autonomously controls the actuator based at least in part on the electrical parameters measured at the receptacle, electrical parameters from one or more disparate electrical outlets in the microgrid, and a supply of generated electric power in the microgrid at a given time.

  20. Demonstrating Fuel Consumption and Emissions Reductions with Next Generation Model-Based Diesel Engine Control

    Office of Energy Efficiency and Renewable Energy (EERE)

    Presents a next generation model-based engine controller that incorporates real-time fuel efficiency optimization and tested under fully transient engine and vehicle operating conditions.

  1. Load regulating expansion fixture

    DOE Patents [OSTI]

    Wagner, L.M.; Strum, M.J.

    1998-12-15

    A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils is disclosed. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components. 1 fig.

  2. Load regulating expansion fixture

    DOE Patents [OSTI]

    Wagner, Lawrence M. (San Jose, CA); Strum, Michael J. (San Jose, CA)

    1998-01-01

    A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components.

  3. GENERATING Tmix-BASED TCP APPLICATION WORKLOADS IN NS-2 AND GTNetS

    E-Print Network [OSTI]

    Weigle, Michele

    GENERATING Tmix-BASED TCP APPLICATION WORKLOADS IN NS-2 AND GTNetS A Thesis Presented in which a set of applications, or a set of users, is simulated to generate traffic simulations. The source-level a-b-t model and accompanying tmix traffic generator for testbeds was developed

  4. UNCORRECTED 2 Pedagogically founded courseware generation based on HTN-planning

    E-Print Network [OSTI]

    Melis, Erica

    than a second to generate complex 27courses with an average learning time of about twelve hoursUNCORRECTED PROOF 1 2 Pedagogically founded courseware generation based on HTN-planning 3 Carsten, Germany 6 8 a r t i c l e i n f o 910 Keywords: 11 Technology-supported learning 12 Courseware generation

  5. c 2003 Association for Computational Linguistics Graph-Based Generation of Referring

    E-Print Network [OSTI]

    for the generation of referring expressions; and (4) the combined use of graphs and cost functions paves the wayc 2003 Association for Computational Linguistics Graph-Based Generation of Referring Expressions Eindhoven University of Technology This article describes a new approach to the generation of referring

  6. A d-Sequence based Recursive Random Number Generator Abhishek Parakh

    E-Print Network [OSTI]

    International Association for Cryptologic Research (IACR)

    A d-Sequence based Recursive Random Number Generator Abhishek Parakh Louisiana State University number generators (RNGs) [4] in a manner analogous to the iterative squaring done in the BBS method [5,6]. In this paper we propose a new recursive technique for the use of d-sequences to generate random numbers

  7. Security Bounds for the NIST Codebook-based Deterministic Random Bit Generator

    E-Print Network [OSTI]

    International Association for Cryptologic Research (IACR)

    Security Bounds for the NIST Codebook-based Deterministic Random Bit Generator Matthew J. Campagna random bit generators are analyzed in the context of being indistinguishable from random. Upper and lower Introduction Random bit generation is an essential element to almost every cryptographic system. A fundamental

  8. Evaluation of Counter-Based Dynamic Load Balancing Schemes for Massive Contingency Analysis on Over 10,000 Cores

    SciTech Connect (OSTI)

    Chen, Yousu; Huang, Zhenyu; Rice, Mark J.

    2012-12-27

    Contingency analysis studies are necessary to assess the impact of possible power system component failures. The results of the contingency analysis are used to ensure the grid reliability, and in power market operation for the feasibility test of market solutions. Currently, these studies are performed in real time based on the current operating conditions of the grid with a set of pre-selected contingency list, which might result in overlooking some critical contingencies caused by variable system status. To have a complete picture of a power grid, more contingencies need to be studied to improve grid reliability. High-performance computing techniques hold the promise of being able to perform the analysis for more contingency cases within a much shorter time frame. This paper evaluates the performance of counter-based dynamic load balancing schemes for a massive contingency analysis program on 10,000+ cores. One million N-2 contingency analysis cases with a Western Electricity Coordinating Council power grid model have been used to demonstrate the performance. The speedup of 3964 with 4096 cores and 7877 with 10240 cores are obtained. This paper reports the performance of the load balancing scheme with a single counter and two counters, describes disk I/O issues, and discusses other potential techniques for further improving the performance.

  9. Generation of Hierarchical Dictionary for Stroke-order Free Kanji Handwriting Recognition Based on Substroke HMM. 

    E-Print Network [OSTI]

    Nakai, Mitsuru; Shimodaira, Hiroshi; Sagayama, Shigeki

    2003-01-01

    This paper describes a method of generating a Kanji hierarchical structured dictionary for stroke-number and stroke-order free handwriting recognition based on sub-stroke HMM. In stroke-based methods, a large number of ...

  10. Biomass gasification for gas turbine-based power generation

    SciTech Connect (OSTI)

    Paisley, M.A.; Anson, D.

    1998-04-01

    The Biomass Power Program of the US Department of Energy (DOE) has as a major goal the development of cost-competitive technologies for the production of power from renewable biomass crops. The gasification of biomass provides the potential to meet this goal by efficiently and economically producing a renewable source of a clean gaseous fuel suitable for use in high-efficiency gas turbines. This paper discusses the development and first commercial demonstration of the Battelle high-throughput gasification process for power generation systems. Projected process economics are presented along with a description of current experimental operations coupling a gas turbine power generation system to the research scale gasifier and the process scaleup activities in Burlington, Vermont.

  11. Generator for ionic gallium-68 based on column chromatography

    DOE Patents [OSTI]

    Neirinckx, Rudi D. (Medfield, MA); Davis, Michael A. (Westwood, MA)

    1981-01-01

    A physiologically acceptable solution of gallium-68 fluorides, having an activity of 0.1 to 50 millicuries per milliliter of solution is provided. The solution is obtained from a generator comprising germanium-68 hexafluoride bound to a column of an anion exchange resin which forms gallium-68 in situ by eluting the column with an acid solution to form a solution containing .sup.68 Ga-fluorides. The solution then is neutralized prior to administration.

  12. Aalborg Universitet ARIMA-Based Time Series Model of Stochastic Wind Power Generation

    E-Print Network [OSTI]

    Bak-Jensen, Birgitte

    the nonstationarity and physical limits of stochastic wind power generation. The model is constructed based on wind power measurement of one year from the Nysted offshore wind farm in Denmark. The proposed limitedAalborg Universitet ARIMA-Based Time Series Model of Stochastic Wind Power Generation Chen, Peiyuan

  13. Molecular Self-assembly-Based Language Generation Using the Hypernetwork Model: Design of DNA Computing Experiments

    E-Print Network [OSTI]

    Molecular Self-assembly-Based Language Generation Using the Hypernetwork Model: Design of DNA Intelligence Magazine, vol.3, no.3, pp.49-63, 2008. [4] Zhang, B.-T. and Park, C.-H., Self-assembling.-H., Lee, E.-S. and Zhang, B.-T., A hypernetwork memory-Based model of sentence learning and generation

  14. Microwave andTerahertz Generation Based on Photonically Assisted Microwave Frequency

    E-Print Network [OSTI]

    Yao, Jianping

    Microwave andTerahertz Generation Based on Photonically Assisted Microwave Frequency Twelvetupling Member, IEEE DOI: 10.1109/JPHOT.2010.2084993 1943-0655/$26.00 ©2010 IEEE #12;Microwave and Terahertz Generation Based on Photonically Assisted Microwave Frequency Twelvetupling With Large Tunability Wangzhe Li

  15. Sampling-Based Direct Trajectory Generation Using the Minimum Time Cost Function

    E-Print Network [OSTI]

    Collins, Emmanuel

    Sampling-Based Direct Trajectory Generation Using the Minimum Time Cost Function Oscar Chuy for computationally efficient, direct trajectory generation using sampling with the minimum time cost function, where" (i.e, a rigorous lower bound on the chosen cost) based on the solution of a minimum time control

  16. Optical Arbitrary Waveform Generation Based Optical-Label Switching Transmitter with

    E-Print Network [OSTI]

    Kolner, Brian H.

    Optical Arbitrary Waveform Generation Based Optical-Label Switching Transmitter with All-Optical, 95616 Email: sbyoo@ucdavis.edu Abstract: This paper introduces a modulation-format transparent optical-label switching transmitter based on optical arbitrary waveform generation. Packets consisting of 100 Gb

  17. Relational-Grammar-Based Generation in the JETS Japanese-English Machine Translation System

    E-Print Network [OSTI]

    Relational-Grammar-Based Generation in the JETS Japanese-English Machine Translation System David E This paper describes the design and func- tioning of the English generation phase in JETS, a limited transfer This paper discusses relational-grammar-based gener- ation in the context of JETS, a Japanese-English machine

  18. Oxide based thermoelectric materials for large scale power generation

    E-Print Network [OSTI]

    Song, Yang, M. Eng. Massachusetts Institute of Technology

    2008-01-01

    The thermoelectric (TE) devices are based on the Seebeck and Peltier effects, which describe the conversion between temperature gradient and electricity. The effectiveness of the material performance can be described by ...

  19. Flexible Micro Thermoelectric Generator based on Electroplated Bi2Te3

    E-Print Network [OSTI]

    Schwyter, E; Durrer, L; Hierold, Ch

    2008-01-01

    We present and discuss the fabrication process and the performance of a flexible micro thermoelectric generator with electroplated Bi2Te3 thermocouples in a SU-8 mold. Demonstrator devices generate 278uWcm-2 at dTmeas=40K across the experimental set up. Based on model calculations, a temperature difference of dTG=21.4K across the generator is assumed. Due to the flexible design and the chosen generator materials, the performance stays high even for curved contact surfaces. The measurement results correlate well with the model based design optimization predictions.

  20. Study and Development of Anti-Islanding Control for Synchronous Machine-Based Distributed Generators: November 2001--March 2004

    SciTech Connect (OSTI)

    Ye, Z.

    2006-03-01

    This report summarizes the study and development of new active anti-islanding control schemes for synchronous machine-based distributed generators, including engine generators and gas turbines.

  1. A Role Casting Method Based on Emotions in a Story Generation System

    E-Print Network [OSTI]

    Thawonmas, Ruck

    A Role Casting Method Based on Emotions in a Story Generation System Ruck Thawonmas1 , Masanao point out a problem in the role casting method of a story generation system called OPIATE and then propose a solution to this problem. The existing casting method does not take into account the emotions

  2. Direct Power Control of Doubly-Fed Generator Based Wind Turbine Converters to Improve Low Voltage

    E-Print Network [OSTI]

    Kimball, Jonathan W.

    by an Industrial Power Corruptor (IPC) in the laboratory. I. INTRODUCTION The new grid code requirements for windDirect Power Control of Doubly-Fed Generator Based Wind Turbine Converters to Improve Low Voltage power integration state that doubly fed induction generator (DFIG) controllers should be capable

  3. MOUNTAIN: A Translation-based Approach to Natural Language Generation for Dialog

    E-Print Network [OSTI]

    Black, Alan W

    MOUNTAIN: A Translation-based Approach to Natural Language Generation for Dialog Systems Brian, USA {blangner,awb}@cs.cmu.edu Abstract. This paper describes the Mountain language generation system a corpus of in-domain human responses, and show typical output of the Mountain system. The results of our

  4. Multiple-Polynomial LFSR based Pseudorandom Number Generator for EPC Gen2 RFID Tags

    E-Print Network [OSTI]

    Garcia-Alfaro, Joaquin

    hardware implementation and energy consumption than previous designs reported in the literature. I. The proposal successfully handles the inherent linearity of LFSR based PRNGs and satisfies the statistical requirements imposed by the EPC Gen2 standard. Statistical analysis of the sequences generated by our generator

  5. Generation of Test Based on Test Ontology Larisa Soldatova, Riichiro Mizoguchi

    E-Print Network [OSTI]

    Mizoguchi, Riichiro

    : In this paper design of test generation systems (TGS) based on a test ontology is discussed. Top level concepts, identify test tasks, and standardize components of TGS. Main functions, regimes, and components of TGS

  6. An enhanced algorithm for protocol conformance test sequence generation based on the UIO method 

    E-Print Network [OSTI]

    Allada, Ravindra

    1993-01-01

    An Enhanced Algorithm for Protocol Conformance Test Sequence Generation Based on the UIO Method. (December 1993) Ravindra Allada, B.E., Osmania University, Hyderabad, India Chair of Advisory Committee: Dr. Hosame Abu-Amara ...

  7. Optimal Load Management System for Aircraft Electric Power Distribution

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Nuzzo, Pierluigi; Iandola, Forrest; Kamgarpour, Maryam; Sangiovanni-Vincentelli, Alberto; Tomlin, Claire

    2014-01-01

    Optimal Load Management System for Aircraft Electric Poweris to develop an optimal load management system based on thescheme where a high-level load management system receives as

  8. Waste Classification based on Waste Form Heat Generation in Advanced Nuclear Fuel Cycles Using the Fuel-Cycle Integration and Tradeoffs (FIT) Model

    SciTech Connect (OSTI)

    Denia Djokic; Steven J. Piet; Layne F. Pincock; Nick R. Soelberg

    2013-02-01

    This study explores the impact of wastes generated from potential future fuel cycles and the issues presented by classifying these under current classification criteria, and discusses the possibility of a comprehensive and consistent characteristics-based classification framework based on new waste streams created from advanced fuel cycles. A static mass flow model, Fuel-Cycle Integration and Tradeoffs (FIT), was used to calculate the composition of waste streams resulting from different nuclear fuel cycle choices. This analysis focuses on the impact of waste form heat load on waste classification practices, although classifying by metrics of radiotoxicity, mass, and volume is also possible. The value of separation of heat-generating fission products and actinides in different fuel cycles is discussed. It was shown that the benefits of reducing the short-term fission-product heat load of waste destined for geologic disposal are neglected under the current source-based radioactive waste classification system , and that it is useful to classify waste streams based on how favorable the impact of interim storage is in increasing repository capacity.

  9. Waste Classification based on Waste Form Heat Generation in Advanced Nuclear Fuel Cycles Using the Fuel-Cycle Integration and Tradeoffs (FIT) Model - 13413

    SciTech Connect (OSTI)

    Djokic, Denia [Department of Nuclear Engineering, University of California - Berkeley, 4149 Etcheverry Hall, Berkeley, CA 94720-1730 (United States)] [Department of Nuclear Engineering, University of California - Berkeley, 4149 Etcheverry Hall, Berkeley, CA 94720-1730 (United States); Piet, Steven J.; Pincock, Layne F.; Soelberg, Nick R. [Idaho National Laboratory - INL, 2525 North Fremont Avenue, Idaho Falls, ID 83415 (United States)] [Idaho National Laboratory - INL, 2525 North Fremont Avenue, Idaho Falls, ID 83415 (United States)

    2013-07-01

    This study explores the impact of wastes generated from potential future fuel cycles and the issues presented by classifying these under current classification criteria, and discusses the possibility of a comprehensive and consistent characteristics-based classification framework based on new waste streams created from advanced fuel cycles. A static mass flow model, Fuel-Cycle Integration and Tradeoffs (FIT), was used to calculate the composition of waste streams resulting from different nuclear fuel cycle choices. This analysis focuses on the impact of waste form heat load on waste classification practices, although classifying by metrics of radiotoxicity, mass, and volume is also possible. The value of separation of heat-generating fission products and actinides in different fuel cycles is discussed. It was shown that the benefits of reducing the short-term fission-product heat load of waste destined for geologic disposal are neglected under the current source-based radioactive waste classification system, and that it is useful to classify waste streams based on how favorable the impact of interim storage is in increasing repository capacity. (authors)

  10. Communication systems, transceivers, and methods for generating data based on channel characteristics

    DOE Patents [OSTI]

    Forman, Michael A; Young, Derek

    2012-09-18

    Examples of methods for generating data based on a communications channel are described. In one such example, a processing unit may generate a first vector representation based in part on at least two characteristics of a communications channel. A constellation having at least two dimensions may be addressed with the first vector representation to identify a first symbol associated with the first vector representation. The constellation represents a plurality of regions, each region associated with a respective symbol. The symbol may be used to generate data, which may stored in an electronic storage medium and used as a cryptographic key or a spreading code or hopping sequence in a modulation technique.

  11. 2006 Pacific Northwest Loads and Resources Study.

    SciTech Connect (OSTI)

    United States. Bonneville Power Administration.

    2006-03-01

    The Pacific Northwest Loads and Resources Study (White Book), which is published annually by the Bonneville Power Administration (BPA), establishes one of the planning bases for supplying electricity to customers. The White Book contains projections of regional and Federal system load and resource capabilities, along with relevant definitions and explanations. The White Book also contains information obtained from formalized resource planning reports and data submittals including those from individual utilities, the Northwest Power and Conservation Council (Council), and the Pacific Northwest Utilities Conference Committee (PNUCC). The White Book is not an operational planning guide, nor is it used for determining BPA revenues, although the database that generates the data for the White Book analysis contributes to the development of BPA's inventory and ratemaking processes. Operation of the Federal Columbia River Power System (FCRPS) is based on a set of criteria different from that used for resource planning decisions. Operational planning is dependent upon real-time or near-term knowledge of system conditions that include expectations of river flows and runoff, market opportunities, availability of reservoir storage, energy exchanges, and other factors affecting the dynamics of operating a power system. The load resource balance of both the Federal system and the region is determined by comparing resource availability to an expected level of total retail electricity consumption. Resources include projected energy capability plus contract purchases. Loads include a forecast of retail obligations plus contract obligations. Surplus energy is available when resources are greater than loads. This surplus energy could be marketed to increase revenues. Energy deficits occur when resources are less than loads. These energy deficits will be met by any combination of the following: better-than-critical water conditions, demand-side management and conservation programs, permanent loss of loads due to economic conditions or closures, additional contract purchases, and/or the addition of new generating resources. This study incorporates information on Pacific Northwest (PNW) regional retail loads, contract obligations, and contract resources. This loads and resources analysis simulates the operation of the power system in the PNW. The simulated hydro operation incorporates plant characteristics, streamflows, and non-power requirements from the current Pacific Northwest Coordination Agreement (PNCA). Additional resource capability estimates were provided by BPA, PNW Federal agency, public agency, cooperative, U.S. Bureau of Reclamation (USBR), and investor-owned utility (IOU) customers furnished through annual PNUCC data submittals for 2005 and/or direct submittals to BPA. The 2006 White Book is presented in two documents: (1) this summary document of Federal system and PNW region loads and resources, and (2) a technical appendix which presents regional loads, grouped by major PNW utility categories, and detailed contract and resource information. The technical appendix is available only in electronic form. Individual customer information for marketer contracts is not detailed due to confidentiality agreements. The 2006 White Book analysis updates the 2004 White Book. This analysis shows projections of the Federal system and region's yearly average annual energy consumption and resource availability for the study period, OY 2007-2016. The study also presents projections of Federal system and region expected 1-hour monthly peak demand, monthly energy demand, monthly 1-hour peak generating capability, and monthly energy generation for OY 2007, 2011, and 2016. BPA is investigating a new approach in capacity planning depicting the monthly Federal system 120-hour peak generating capability and 120-hour peak surplus/deficit for OY 2007, 2011, and 2016. This document analyzes the PNW's projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency;

  12. AIAA-2004-0502 A COMPARISON OF WIND TURBINE DESIGN LOADS IN DIFFERENT

    E-Print Network [OSTI]

    Manuel, Lance

    wind speed. For wind turbine generator systems, a similar reliability-based design format is employedAIAA-2004-0502 1 A COMPARISON OF WIND TURBINE DESIGN LOADS IN DIFFERENT ENVIRONMENTS USING INVERSE, Austin, TX 78712 ABSTRACT* The influence of turbulence conditions on the design loads for wind turbines

  13. Phosphine-Catalyzed Hydration and Hydroalkoxylation of Activated Olefins: Use of a Strong Nucleophile to Generate a Strong Base

    E-Print Network [OSTI]

    Toste, Dean

    Nucleophile to Generate a Strong Base Ian C. Stewart, Robert G. Bergman,* and F. Dean Toste* Center for New

  14. *jerlynch@umich.edu; phone 1 734 615 5290; http://www-personal.engin.umich.edu/~jerlynch Local-based damage detection of cyclically loaded bridge piers using

    E-Print Network [OSTI]

    Lynch, Jerome P.

    -based damage detection of cyclically loaded bridge piers using wireless sensing units Tsung-Chin Hou, Jerome P of Michigan, Ann Arbor, MI 48109 ABSTRACT Concrete bridge piers are a common structural element employed in the design of bridges and elevated roadways. In order to ensure adequate behavior under earthquake

  15. Optimization of sequential attractor-based movement for compact behaviour generation

    E-Print Network [OSTI]

    Toussaint, Marc

    Optimization of sequential attractor-based movement for compact behaviour generation Marc Toussaint optimal robot motion based on a sequence of attractor dynamics in task space. This is motivated] ­ and by the need for compact movement representations on which efficient optimization can be performed. We

  16. Schematic Generation of English-prose Semantics for a Risk Analysis Language Based on UML Interactions

    E-Print Network [OSTI]

    Stølen, Ketil

    Schematic Generation of English-prose Semantics for a Risk Analysis Language Based on UML risk-driven testing, we have developed CORAL, a language for risk analysis based on UML interac- tions that is linear to the complexity of CORAL diagrams in terms of size. Keywords-risk analysis language; risk

  17. Width-tunable pulse generation using four-wave mixing in bismuth based highly nonlinear fiber

    E-Print Network [OSTI]

    Wai, Ping-kong Alexander

    Width-tunable pulse generation using four-wave mixing in bismuth based highly nonlinear fiber-cho, Yokohama 221-8755, Japan Received 15 August 2006; received in revised form 28 February 2007; accepted 5 of a compact and all-fiber based width-tunable pulse gen- erator using four-wave mixing (FWM) effect in only 1

  18. Environmental Assessment for DOE permission for off-loading activities to support the movement of Millstone Unit 2 steam generator sub-assemblies across the Savannah River Site

    SciTech Connect (OSTI)

    Not Available

    1992-10-01

    The Department of Energy (DOE) has prepared an Environmental Assessment (EA), for the proposed granting of DOE permission of offloading activities to support the movement Millstone Unit 2 steam generator sub-assemblies (SGSAs) across the Savannah River Site (SRS). Based on the analyses in the EA, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, an environmental impact statement is not required, and the Department is issuing this Finding of No Significant Impact. On the basis of the floodplain/wetlands assessment in the EA, DOE has determined that there is no practicable alternative to the proposed activities and that the proposed action has been designed to minimize potential harm to or within the floodplain of the SRS boat ramp. No wetlands on SRS would be affected by the proposed action.

  19. Research on Short-term Load Forecasting of the Thermoelectric Boiler Based on a Dynamic RBF Neural Network 

    E-Print Network [OSTI]

    Dai, W.; Zou, P.; Yan, C.

    2006-01-01

    As thermal inertia is the key factor for the lag of thermoelectric utility regulation, it becomes very important to forecast its short-term load according to running parameters. In this paper, dynamic radial basis function ...

  20. Phase change based cooling for high burst mode heat loads with temperature regulation above the phase change temperature

    DOE Patents [OSTI]

    The United States of America as represented by the United States Department of Energy (Washington, DC)

    2009-12-15

    An apparatus and method for transferring thermal energy from a heat load is disclosed. In particular, use of a phase change material and specific flow designs enables cooling with temperature regulation well above the fusion temperature of the phase change material for medium and high heat loads from devices operated intermittently (in burst mode). Exemplary heat loads include burst mode lasers and laser diodes, flight avionics, and high power space instruments. Thermal energy is transferred from the heat load to liquid phase change material from a phase change material reservoir. The liquid phase change material is split into two flows. Thermal energy is transferred from the first flow via a phase change material heat sink. The second flow bypasses the phase change material heat sink and joins with liquid phase change material exiting from the phase change material heat sink. The combined liquid phase change material is returned to the liquid phase change material reservoir. The ratio of bypass flow to flow into the phase change material heat sink can be varied to adjust the temperature of the liquid phase change material returned to the liquid phase change material reservoir. Varying the flowrate and temperature of the liquid phase change material presented to the heat load determines the magnitude of thermal energy transferred from the heat load.

  1. Load Management Made Simple 

    E-Print Network [OSTI]

    Schneider, K.

    1985-01-01

    Company have moved to a demand side or load management mode which seeks to influence customers to change electric usage patterns to more efficiently use available generating capacity. Since 1970, the TUEC system peak demand has more than doubled from about...

  2. Welfare Impacts of Electricity Generation Sector Reform in the Philippines

    E-Print Network [OSTI]

    Toba, Natsuko

    2004-06-16

    ) and the lack of a long-term debt instrument in the domestic financial system; (iv) inordinate delays in implementing new base load plants and in environmental clearances due to the public protests; (v) declining hydro power generation capacity; (vi...

  3. Combining Audio-based Similarity with Web-based Data to Accelerate Automatic Music Playlist Generation

    E-Print Network [OSTI]

    Widmer, Gerhard

    Generation Peter Knees1 , Tim Pohle1 , Markus Schedl1 , and Gerhard Widmer1,2 1 Department of Computational Intelligence (OFAI) peter.knees@jku.at, tim.pohle@jku.at, markus.schedl@jku.at, gerhard.widmer@jku.at ABSTRACT from intelligent structuring of audio collections. While the original approach involves the calculation

  4. LOAD FORECASTING Eugene A. Feinberg

    E-Print Network [OSTI]

    Feinberg, Eugene A.

    , regression, artificial intelligence. 1. Introduction Accurate models for electric power load forecasting to make important decisions including decisions on pur- chasing and generating electric power, load for different operations within a utility company. The natures 269 #12;270 APPLIED MATHEMATICS FOR POWER SYSTEMS

  5. Neural Network Based Modeling of a Large Steam Turbine-Generator Rotor Body Parameters from On-Line Disturbance Data

    E-Print Network [OSTI]

    Neural Network Based Modeling of a Large Steam Turbine-Generator Rotor Body Parameters from On technique to estimate and model rotor- body parameters of a large steam turbine-generator from real time

  6. A Generative Approach for Image-Based Modeling of Tumor Growth

    E-Print Network [OSTI]

    Golland, Polina

    A Generative Approach for Image-Based Modeling of Tumor Growth Bjoern H. Menze1,2 , Koen Van Golland1 1 Computer Science and Artificial Intelligence Laboratory, Massachusetts Institute of Technology University, Finland 5 Helsinki Institute for Information Technology HIIT, University of Helsinki, Finland 6

  7. Enhanced Ferroelectric-Nanocrystal-Based Hybrid Photocatalysis by Ultrasonic-Wave-Generated Piezophototronic Effect

    E-Print Network [OSTI]

    Wang, Zhong L.

    , which is the fundamental of sonophotocatalysis. KEYWORDS: built-in electric field, ultrasonic waveEnhanced Ferroelectric-Nanocrystal-Based Hybrid Photocatalysis by Ultrasonic-Wave-Generated, Atlanta, Georgia 30332-0245, United States *S Supporting Information ABSTRACT: An electric field built

  8. Aalborg Universitet Stored Energy Balance for Distributed PV-Based Active Generators in an AC Microgrid

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    Microgrid Aldana, Nelson Leonardo Diaz; Wu, Dan; Dragicevic, Tomislav; Quintero, Juan Carlos Vasquez). Stored Energy Balance for Distributed PV-Based Active Generators in an AC Microgrid. In Proceedings Microgrid Nelson L. Diaz, Dan Wu, Tomislav Dragicevic, Juan C. Vasquez, and Josep M. Guerrero Abstract

  9. Tool-Assisted Unit-Test Generation and Selection Based on Operational Abstractions

    E-Print Network [OSTI]

    Xie, Tao

    Tool-Assisted Unit-Test Generation and Selection Based on Operational Abstractions Tao Xie1 of Washington, Seattle, WA 98105 Abstract. Unit testing, a common step in software development, presents a chal- lenge. When produced manually, unit test suites are often insufficient to identify defects. The main

  10. DURATION AND SPECTRAL BASED STRESS TOKEN GENERATION FOR HMM SPEECH RECOGNITION UNDER STRESS*

    E-Print Network [OSTI]

    Texas at Dallas, University of

    DURATION AND SPECTRAL BASED STRESS TOKEN GENERATION FOR HMM SPEECH RECOGNITION UNDER STRESS* Sahar In this paper, we address the problem of isolated word recognition of speech under various stressed speaking con recognition, which better characterizes actual speech production under stressed speaking styles such as slow

  11. BATTRI: A TWO-DIMENSIONAL BATHYMETRY BASED UNSTRUCTURED TRIANGULAR GRID GENERATOR

    E-Print Network [OSTI]

    of Delaunay unstructured triangular grid refinement algorithms, including the recent "off-centers" method Delaunay scheme, called "off-centers" [10], on reducing the number of grid nodes without sacrificingBATTRI: A TWO-DIMENSIONAL BATHYMETRY BASED UNSTRUCTURED TRIANGULAR GRID GENERATOR FOR FINITE

  12. Generating Pedestrian Trajectories Consistent with the Fundamental Diagram based on Physiological and Psychological

    E-Print Network [OSTI]

    North Carolina at Chapel Hill, University of

    1 Generating Pedestrian Trajectories Consistent with the Fundamental Diagram based on Physiological Pedestrian crowds often have been modeled as many-particle system including microscopic multi-agent simulators. One of the key challenges is to unearth governing principles that can model pedestrian movement

  13. Price-Maker Economic Bidding in Two-Settlement Pool-Based Markets: The Case of Time-Shiftable Loads

    E-Print Network [OSTI]

    Mohsenian-Rad, Hamed

    are found for the price and energy bids within a relatively short amount of computational time. A detailed bidding, price bids, energy bids, day-ahead market, real-time market, time-shiftable loads, demand to day-ahead market y Energy bid to real-time market p Price bid submitted to the day-ahead market

  14. A small-signal generator based on a multi-layer graphene/molybdenum disulfide heterojunction

    SciTech Connect (OSTI)

    Tan, Zhen; Tian, He; Feng, Tingting; Zhao, Lianfeng; Xie, Dan; Yang, Yi; Xiao, Lei; Wang, Jing; Ren, Tian-Ling E-mail: JunXu@tsinghua.edu.cn; Xu, Jun E-mail: JunXu@tsinghua.edu.cn

    2013-12-23

    In this work, we fabricate a heterojunction small-signal generator (HSSG) based on a graphene-molybdenum disulfide (MoS{sub 2}) heterojunction. The HSSG is fundamentally different from any analog device developed previously. The HSSG is composed of two quasi-2D heterojunctions and has three terminals named injector (I), recombinator (R), and generator (G). MoS{sub 2} serves as I and G, and graphene works as R in the HSSG. The scale coefficient (??=?I{sub G}/I{sub R}) of the HSSG is 1.14?×?10{sup ?4} (V{sub IG,?IR}?=?0.2?V) to 1.95?×?10{sup ?4} (V{sub IG,?IR}?=?1?V). The current generated from G could be as low as pA scale, which reveals the good performance of the HSSG.

  15. Demonstration of Advanced Technologies for Multi-Load Washers in Hospitality and Healthcare -- Ozone Based Laundry Systems

    SciTech Connect (OSTI)

    Boyd, Brian K.; Parker, Graham B.; Petersen, Joseph M.; Sullivan, Greg; Goetzler, W.; Sutherland, T. A.; Foley, K. J.

    2014-08-14

    The objective of this demonstration project was to evaluate market-ready retrofit technologies for reducing the energy and water use of multi-load washers in healthcare and hospitality facilities. Specifically, this project evaluated laundry wastewater recycling technology in the hospitality sector and ozone laundry technology in both the healthcare and hospitality sectors. This report documents the demonstration of ozone laundry system installations at the Charleston Place Hotel in Charleston, South Carolina, and the Rogerson House assisted living facility in Boston, Massachusetts.

  16. 668 IEEE PHOTONICS TECHNOLOGY LETTERS, VOL. 19, NO. 9, MAY 1, 2007 Photonic Generation of Microwave Signals Based

    E-Print Network [OSTI]

    Yao, Jianping

    668 IEEE PHOTONICS TECHNOLOGY LETTERS, VOL. 19, NO. 9, MAY 1, 2007 Photonic Generation of Microwave, IEEE Abstract--A novel approach to generating microwave signals based on optical pulse shaping generation is developed. Experimental results agree well with the theoretical analysis. Index Terms--Microwave

  17. SEI 03 Microseisms interpreted as coastal reflections of ocean waves generated by storms based on Mexico Array data

    E-Print Network [OSTI]

    Soatto, Stefano

    SEI 03 Microseisms interpreted as coastal reflections of ocean waves generated by storms based relative to the stations. Both theories describe microseisms generated in interfering ocean surface waves will call the HR theory, proposes that the microseisms are generated by the ocean waves from the storms

  18. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 58, NO. 7, JULY 2010 1967 Tunable Subterahertz Wave Generation Based on

    E-Print Network [OSTI]

    Yao, Jianping

    Subterahertz Wave Generation Based on Photonic Frequency Sextupling Using a Polarization Modulator to generate high-spectral-purity subterahertz wave signals using relatively low-frequency electrical-bandwidth notch filter by an optical interleaver, a subterahertz wave tunable from 66 to 114 GHz is generated when

  19. Empirical study on the efficiency of search based test generation for EFSM models Ruilian Zhao, Mark Harman and Zheng Li

    E-Print Network [OSTI]

    Harman, Mark

    correlation between test generation cost and the number of numerical equal operators in conditions (NNEOC that there is very strong exponential relationship between test generation cost and NNEV or LPEV only when NNEOCEmpirical study on the efficiency of search based test generation for EFSM models Ruilian Zhao

  20. Modeling and Forecasting Electric Daily Peak Loads

    E-Print Network [OSTI]

    Abdel-Aal, Radwan E.

    for the same data. Two methods are described for forecasting daily peak loads up to one week ahead through, including generator unit commitment, hydro-thermal coordination, short-term maintenance, fuel allocation forecasting accuracies. STLF forecasting covers the daily peak load, total daily energy, and daily load curve

  1. Dynamic load balancing of applications

    DOE Patents [OSTI]

    Wheat, S.R.

    1997-05-13

    An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers is disclosed. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated. 13 figs.

  2. Dynamic load balancing of applications

    DOE Patents [OSTI]

    Wheat, Stephen R. (Albuquerque, NM)

    1997-01-01

    An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated.

  3. Flat-top pulse generation based on the combined action of active mode locking and nonlinear polarization rotation

    E-Print Network [OSTI]

    Wai, Ping-kong Alexander

    Flat-top pulse generation based on the combined action of active mode locking and nonlinear: A pulsewidth tunable 10 GHz flat-top pulse train is generated based on the combined action of active mode locking and nonlinear-polarization-rotation pulse shaping. The SMSR is 65 dB and the timing jitter is 145

  4. Knowledge-based Patient Data Generation Zhisheng Huang, Frank van Harmelen, Annette ten Teije, and Kathrin Dentler

    E-Print Network [OSTI]

    van Harmelen, Frank

    Knowledge-based Patient Data Generation Zhisheng Huang, Frank van Harmelen, Annette ten Teije and the quality of the data. By defining the required format, data can easily be generated based on realistic,Frank.van.Harmelen,annette,k.dentler}@cs.vu.nl Abstract. The development and investigation of medical applications require patient data from various

  5. Stresa, Italy, 26-28 April 2006 A SILICON-BASED MICRO GAS TURBINE ENGINE FOR POWER GENERATION

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Stresa, Italy, 26-28 April 2006 A SILICON-BASED MICRO GAS TURBINE ENGINE FOR POWER GENERATION X. C in developing a micro power generation system based on gas turbine engine and piezoelectric converter. The micro gas turbine engine consists of a micro combustor, a turbine and a centrifugal compressor

  6. JOURNAL OF LIGHTWAVE TECHNOLOGY, VOL. 24, NO. 7, JULY 2006 2663 Broadband Arbitrary Waveform Generation Based on

    E-Print Network [OSTI]

    Fischer, Baruch

    Generation Based on Microwave Frequency Upshifting in Optical Fibers José Azaña, Member, IEEE, Naum K. Berger, Boris Levit, and Baruch Fischer Abstract--An interesting method for broadband arbitrary waveform generation is based on the frequency upshifting of a narrowband microwave signal. In this technique

  7. Synthesis and Characterization of Iridium- and Cobalt-based Skutterudites for Thermoelectric Power Generation

    E-Print Network [OSTI]

    King, Daniel Jay

    2014-01-01

    for thermoelectric power generation,” 235th ACS Nationalfor Thermoelectric Power Generation A dissertation submittedfor Thermoelectric Power Generation by Daniel Jay King, Jr.

  8. Changes in the Economic Value of Variable Generation at High Penetration Levels: A Pilot Case Study of California

    E-Print Network [OSTI]

    Mills, Andrew

    2013-01-01

    generation, including hourly generation and load profiles,by incorporating hourly generation and load profiles,power with the same hourly generation profile. The marginal

  9. Microfiber-based gold nanorods as saturable absorber for femtosecond pulse generation in a fiber laser

    SciTech Connect (OSTI)

    Wang, Xu-De [Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou, Guangdong 510006 (China); School of Physics and Electronic Information, Huaibei Normal University, Huaibei, Anhui 235000 (China); Luo, Zhi-Chao; Liu, Hao; Liu, Meng; Luo, Ai-Ping, E-mail: luoaiping@scnu.edu.cn; Xu, Wen-Cheng, E-mail: xuwch@scnu.edu.cn [Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou, Guangdong 510006 (China)

    2014-10-20

    We reported on the femtosecond pulse generation from an erbium-doped fiber (EDF) laser by using microfiber-based gold nanorods (GNRs) as saturable absorber (SA). By virtue of the geometric characteristic of microfiber-based GNRs, the optical damage threshold of GNRs-SA could be greatly enhanced. The microfiber-based GNRs-SA shows a modulation depth of 4.9% and a nonsaturable loss of 21.1%. With the proposed GNRs-SA, the fiber laser emitted a mode-locked pulse train with duration of ?887 fs. The obtained results demonstrated that the GNRs deposited microfiber could indeed serve as a high-performance SA towards the practical applications in the field of ultrafast photonics.

  10. Development and Mass Production of a Mixture of LAB- and DIN-based Gadolinium-loaded Liquid Scintillator for the NEOS Short-baseline Neutrino Experiment

    E-Print Network [OSTI]

    Ba Ro Kim; Boyoung Han; Eun-ju Jeon; Kyung Kwang Joo; H. J. Kim; Hyunsoo Kim; Jinyu Kim; Yeongduk Kim; Youngju Ko; Jaison Lee; Jooyoung Lee; Moohyun Lee; Kyungju Ma; Yoomin Oh; Hyangkyu Park; Kang-soon Park; Kyungmin Seo; Gwang-Min Seon; Kim Siyeon

    2015-11-16

    A new experiment, which is called as NEOS (NEutrino Oscillation at Short baseline), is proposed on the site of Hanbit reactors at Yonggwang, South Korea, to investigate a reactor antineutrino anomaly. A homogeneous NEOS detector having a 1000-L target volume has been constructed and deployed at the tendon gallery ~25 m away from the reactor core. A linear alkylbenzene (LAB) is used as a main base solvent of the NEOS detector. Furthermore, a di-isopropylnaphthalene (DIN) is added to improve the light output and pulse shape discrimination (PSD) ability. The ratio of LAB to DIN is 90:10. PPO (3 g/L) and bis-MSB (30 mg/L) are dissolved to formulate the mixture of LAB- and DIN-based liquid scintillator (LS). Then, ~0.5% gadolinium (Gd) is loaded into the LS by using the solvent-solvent extraction technique. In this paper, we report the characteristics of Gd-loaded LS (GdLS) for the NEOS detector and the handling during mass production.

  11. Economic and Emissions Implications of Load-Based, Source-based and First-seller Emissions Trading Programs under California AB32

    E-Print Network [OSTI]

    Chen, Yihsu; Liu, Andrew L.; Hobbs, Benjamin F.

    2008-01-01

    only generation by California power plants. Meanwhile, theCalifornia is considering three proposals to regulate greenhouse gasses emitted by electric power plants

  12. A Silicon-Based Micro Gas Turbine Engine for Power Generation

    E-Print Network [OSTI]

    Shan, X -C; Maeda, R; Sun, Y F; Wu, M; Hua, J S

    2007-01-01

    This paper reports on our research in developing a micro power generation system based on gas turbine engine and piezoelectric converter. The micro gas turbine engine consists of a micro combustor, a turbine and a centrifugal compressor. Comprehensive simulation has been implemented to optimal the component design. We have successfully demonstrated a silicon-based micro combustor, which consists of seven layers of silicon structures. A hairpin-shaped design is applied to the fuel/air recirculation channel. The micro combustor can sustain a stable combustion with an exit temperature as high as 1600 K. We have also successfully developed a micro turbine device, which is equipped with enhanced micro air-bearings and driven by compressed air. A rotation speed of 15,000 rpm has been demonstrated during lab test. In this paper, we will introduce our research results major in the development of micro combustor and micro turbine test device.

  13. Using Utility Load Data to Estimate Demand for Space Cooling and Potential for Shiftable Loads

    SciTech Connect (OSTI)

    Denholm, P.; Ong, S.; Booten, C.

    2012-05-01

    This paper describes a simple method to estimate hourly cooling demand from historical utility load data. It compares total hourly demand to demand on cool days and compares these estimates of total cooling demand to previous regional and national estimates. Load profiles generated from this method may be used to estimate the potential for aggregated demand response or load shifting via cold storage.

  14. Adapting a GIS-Based Multicriteria Decision Analysis Approach for Evaluating New Power Generating Sites

    SciTech Connect (OSTI)

    Omitaomu, Olufemi A [ORNL; Blevins, Brandon R [ORNL; Jochem, Warren C [ORNL; Mays, Gary T [ORNL; Belles, Randy [ORNL; Hadley, Stanton W [ORNL; Harrison, Thomas J [ORNL; Bhaduri, Budhendra L [ORNL; Neish, Bradley S [ORNL; Rose, Amy N [ORNL

    2012-01-01

    There is a growing need to site new power generating plants that use cleaner energy sources due to increased regulations on air and water pollution and a sociopolitical desire to develop more clean energy sources. To assist utility and energy companies as well as policy-makers in evaluating potential areas for siting new plants in the contiguous United States, a geographic information system (GIS)-based multicriteria decision analysis approach is presented in this paper. The presented approach has led to the development of the Oak Ridge Siting Analysis for power Generation Expansion (OR-SAGE) tool. The tool takes inputs such as population growth, water availability, environmental indicators, and tectonic and geological hazards to provide an in-depth analysis for siting options. To the utility and energy companies, the tool can quickly and effectively provide feedback on land suitability based on technology specific inputs. However, the tool does not replace the required detailed evaluation of candidate sites. To the policy-makers, the tool provides the ability to analyze the impacts of future energy technology while balancing competing resource use.

  15. Designing and Testing Contols to Mitigate Dynamic Loads in the Controls Advanced Research Turbine: Preprint

    SciTech Connect (OSTI)

    Wright, A.D.; Stol, K.A.

    2008-01-01

    The National Renewable Energy Laboratory is designing, implementing, and testing advanced controls to maximize energy extraction and reduce structural dynamic loads of wind turbines. These control designs are based on a linear model of the turbine that is generated by specialized modeling software. In this paper, we show the design and simulation testing of a control algorithm to mitigate blade, tower, and drivetrain loads using advanced state-space control design methods.

  16. Electrical and Production Load Factors 

    E-Print Network [OSTI]

    Sen, Tapajyoti

    2010-07-14

    Load factors are an important simplification of electrical energy use data and depend on the ratio of average demand to peak demand. Based on operating hours of a facility they serve as an important benchmarking tool for the industrial sector...

  17. 1993 Pacific Northwest Loads and Resources Study.

    SciTech Connect (OSTI)

    United States. Bonneville Power Administration.

    1993-12-01

    The Loads and Resources Study is presented in three documents: (1) this summary of Federal system and Pacific Northwest region loads and resources; (2) a technical appendix detailing forecasted Pacific Northwest economic trends and loads, and (3) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. In this loads and resources study, resource availability is compared with a range of forecasted electricity consumption. The forecasted future electricity demands -- firm loads -- are subtracted from the projected capability of existing and {open_quotes}contracted for{close_quotes} resources to determine whether Bonneville Power Administration (BPA) and the region will be surplus or deficit. If resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA can sell to increase revenues. Conversely, if firm loads exceed available resources, there is a deficit of energy and/or capacity, and additional conservation, contract purchases, or generating resources will be needed to meet load growth. The Pacific Northwest Loads and Resources Study analyzes the Pacific Northwest`s projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency; and (2) the larger Pacific Northwest regional power system, which includes loads and resource in addition to the Federal system. The loads and resources analysis in this study simulates the operation of the power system under the Pacific Northwest Coordination Agreement (PNCA) produced by the Pacific Northwest Coordinating Group. This study presents the Federal system and regional analyses for five load forecasts: high, medium-high, medium, medium-low, and low. This analysis projects the yearly average energy consumption and resource availability for Operating Years (OY) 1994--95 through 2003--04.

  18. IEEE PHOTONICS TECHNOLOGY LETTERS, VOL. 22, NO. 10, MAY 15, 2010 715 Optical Arbitrary Waveform Generation-Based

    E-Print Network [OSTI]

    Kolner, Brian H.

    -bit 40-Gb/s label in nonreturn-to-zero and return-to- zero on­off keying formats indicate Generation-Based Packet Generation and All-Optical Separation for Optical-Label Switching Tingting He--This letter introduces a versatile modulation-format transparent optical-label switching (OLS) transmitter

  19. Monitoring of Electrical End-Use Loads in Commercial Buildings 

    E-Print Network [OSTI]

    Martinez, M.; Alereza, T.; Mort, D.

    1988-01-01

    custom-designed to facilitate collection and validation of the end-use load data. For example, the Load Profile Viewer is a PC-based software program for reviewing and validating the end-use load data....

  20. Space-based solar power generation using a distributed network of satellites and methods for efficient space power transmission

    E-Print Network [OSTI]

    McLinko, Ryan M.

    Space-based solar power (SSP) generation is being touted as a solution to our ever-increasing energy consumption and dependence on fossil fuels. Satellites in Earth's orbit can capture solar energy through photovoltaic ...

  1. A new generation of satellite based solar irradiance calculation schemes R. W. Mueller, D. Heinemann, C. Hoyer & R. Kuhlemann

    E-Print Network [OSTI]

    Heinemann, Detlev

    A new generation of satellite based solar irradiance calculation schemes R. W. Mueller, D. Piernavieja Instituto Tecnologico de Canarias, Spain Keywords: radiative transfer, solar irradiance, MSG irradiance calculation scheme, including the functional treatment of the diurnal variation of the solar

  2. Figure 6: An MTAH for 11 lung tumor contours generated by MDISC based on area, circularity, and extrusiveness.

    E-Print Network [OSTI]

    California at Los Angeles, University of

    Figure 6: An MTAH for 11 lung tumor contours generated by M­DISC based on area, circularity, and extrusiveness. Figure 7: The CT scanned lung image for image 6 (in Figure 3) with the lung tumor contour

  3. Measuring the effects of explicit instructions and incentives on the idea generation rate of a crowd-based population

    E-Print Network [OSTI]

    Donnelly, Allan R. (Allan Richard)

    2013-01-01

    Management researchers have long sought strategies for increasing the rate and quality of ideas generated among workers. Additionally, the advent of internet-based communications has created opportunities for valuable ideas ...

  4. Multidimensional spectral load balancing

    SciTech Connect (OSTI)

    Hendrickson, B.; Leland, R.

    1993-01-01

    We describe an algorithm for the static load balancing of scientific computations that generalizes and improves upon spectral bisection. Through a novel use of multiple eigenvectors, our new spectral algorithm can divide a computation into 4 or 8 pieces at once. These multidimensional spectral partitioning algorithms generate balanced partitions that have lower communication overhead and are less expensive to compute than those produced by spectral bisection. In addition, they automatically work to minimize message contention on a hypercube or mesh architecture. These spectral partitions are further improved by a multidimensional generalization of the Kernighan-Lin graph partitioning algorithm. Results on several computational grids are given and compared with other popular methods.

  5. Fuel-cell based power generating system having power conditioning apparatus

    DOE Patents [OSTI]

    Mazumder, Sudip K. (Chicago, IL); Pradhan, Sanjaya K. (Des Plaines, IL)

    2010-10-05

    A power conditioner includes power converters for supplying power to a load, a set of selection switches corresponding to the power converters for selectively connecting the fuel-cell stack to the power converters, and another set of selection switches corresponding to the power converters for selectively connecting the battery to the power converters. The power conveners output combined power that substantially optimally meets a present demand of the load.

  6. A new non linear mechanism able to generate avalanches based on soil mechanics

    E-Print Network [OSTI]

    P. Evesque

    2005-07-04

    We propose a general mechanism based on soil mechanics concepts, such as dilatancy and friction, to explain the fact that avalanches stop at an angle smaller than they start: the mechanism involved is linked to the fact that the stress field near the free surface of a pile built with inclined strata obeys always the plasticity criteria, even when the slope is smaller than the friction angle. It results from this that the larger the slope angle the smaller the mean stress and the smaller the maximum principal stress. So when the pile rotates to generate the next instability the granular material is submitted to a decrease of the mean stress, resulting in an increase of its yielding angle, which becomes larger than the friction angle. The slope starts then flowing at an angle larger than the friction angle.

  7. DEVELOPMENT OF RISK-BASED AND TECHNOLOGY-INDEPENDENT SAFETY CRITERIA FOR GENERATION IV SYSTEMS

    SciTech Connect (OSTI)

    William E. Kastenberg; Edward Blandford; Lance Kim

    2009-03-31

    This project has developed quantitative safety goals for Generation IV (Gen IV) nuclear energy systems. These safety goals are risk based and technology independent. The foundations for a new approach to risk analysis has been developed, along with a new operational definition of risk. This project has furthered the current state-of-the-art by developing quantitative safety goals for both Gen IV reactors and for the overall Gen IV nuclear fuel cycle. The risk analysis approach developed will quantify performance measures, characterize uncertainty, and address a more comprehensive view of safety as it relates to the overall system. Appropriate safety criteria are necessary to manage risk in a prudent and cost-effective manner. This study is also important for government agencies responsible for managing, reviewing, and for approving advanced reactor systems because they are charged with assuring the health and safety of the public.

  8. Application and development of technologies for engine-condition-based maintenance of emergency diesel generators

    SciTech Connect (OSTI)

    Choi, K. H.; Sang, G.; Choi, L. Y. S.; Lee, B. O. [Korea Hydro and Nuclear Power Company Central Research Institue, 70, 1312 -gil Yuseong-daero Yuseong-gu, Daejeon 305-343 (Korea, Republic of)

    2012-07-01

    The emergency diesel generator (EDG) of a nuclear power plant has the role of supplying emergency electric power to protect the reactor core system in the event of the loss of offsite power supply. Therefore, EDGs should be subject to periodic surveillance testing to verify their ability to supply specified frequencies and voltages at design power levels within a limited time. To maintain optimal reliability of EDGs, condition monitoring/diagnosis technologies must be developed. Changing from periodic disassemble maintenance to condition-based maintenance (CBM) according to predictions of equipment condition is recommended. In this paper, the development of diagnosis technology for CBM and the application of a diesel engine condition-analysis system are described. (authors)

  9. Spin-on-doping for output power improvement of silicon nanowire array based thermoelectric power generators

    SciTech Connect (OSTI)

    Xu, B., E-mail: bin.xu09@imperial.ac.uk; Fobelets, K. [Department of Electrical and Electronic Engineering, Imperial College London, Exhibition Road, SW7 2BT London (United Kingdom)

    2014-06-07

    The output power of a silicon nanowire array (NWA)-bulk thermoelectric power generator (TEG) with Cu contacts is improved by spin-on-doping (SOD). The Si NWAs used in this work are fabricated via metal assisted chemical etching (MACE) of 0.01–0.02 ? cm resistivity n- and p-type bulk, converting ~4% of the bulk thickness into NWs. The MACE process is adapted to ensure crystalline NWs. Current-voltage and Seebeck voltage-temperature measurements show that while SOD mainly influences the contact resistance in bulk, it influences both contact resistance and power factor in NWA-bulk based TEGs. According to our experiments, using Si NWAs in combination with SOD increases the output power by an order of 3 under the same heating power due to an increased power factor, decreased thermal conductivity of the NWA and reduced Si-Cu contact resistance.

  10. Static Load Balancing using Non-Uniform Mesh Partitioning based on Ray Density Prediction for the Parallel Wavefront Construction Method 

    E-Print Network [OSTI]

    Alyabes, Abdullah Fahad

    2014-08-01

    USING NON-UNIFORM MESH PARTITIONING BASED ON RAY DENSITY PREDICTION FOR THE PARALLEL WAVEFRONT CONSTRUCTION METHOD A Thesis by ABDULLAH FAHAD ALYABES Submitted to the Office of Graduate and Professional Studies of Texas A&M University in partial... Construction Method . . . . . . . . . . . . . . . . 4 2.3 Parallel Wavefront Construction Performance . . . . . . . . . . . . . 7 2.3.1 Wavefront Mesh Density Prediction . . . . . . . . . . . . . . . 10 2.3.2 Non-uniform Wavefront Mesh Partitioning...

  11. Automatic Generation and Analysis of Physics-Based Puzzle Games Mohammad Shaker, Mhd Hasan Sarhan, Ola Al Naameh, Noor Shaker and Julian Togelius, Member, IEEE

    E-Print Network [OSTI]

    Togelius, Julian

    Automatic Generation and Analysis of Physics-Based Puzzle Games Mohammad Shaker, Mhd Hasan Sarhan a method for the auto- matic generation of content for the physics-based puzzle game Cut The Rope. An evolutionary game generator is implemented which evolves the design of levels based on a context-free gram- mar

  12. Model for Aggregated Water Heater Load Using Dynamic Bayesian Networks

    SciTech Connect (OSTI)

    Vlachopoulou, Maria; Chin, George; Fuller, Jason C.; Lu, Shuai; Kalsi, Karanjit

    2012-07-19

    The transition to the new generation power grid, or “smart grid”, requires novel ways of using and analyzing data collected from the grid infrastructure. Fundamental functionalities like demand response (DR), that the smart grid needs, rely heavily on the ability of the energy providers and distributors to forecast the load behavior of appliances under different DR strategies. This paper presents a new model of aggregated water heater load, based on dynamic Bayesian networks (DBNs). The model has been validated against simulated data from an open source distribution simulation software (GridLAB-D). The results presented in this paper demonstrate that the DBN model accurately tracks the load profile curves of aggregated water heaters under different testing scenarios.

  13. Partition Based Cascaded Generator Scheduling with Constraints for Large Power Networks

    E-Print Network [OSTI]

    Kundur, Deepa

    in the number of distributed generation plants. Physical and computational constraints within the new landscape distributed-generation power plants has increased the complexity of fundamental problems like generator the advantage of the proposed scheme. I. INTRODUCTION The paradigm shift for the power systems from relying

  14. Method of operating a thermoelectric generator

    DOE Patents [OSTI]

    Reynolds, Michael G; Cowgill, Joshua D

    2013-11-05

    A method for operating a thermoelectric generator supplying a variable-load component includes commanding the variable-load component to operate at a first output and determining a first load current and a first load voltage to the variable-load component while operating at the commanded first output. The method also includes commanding the variable-load component to operate at a second output and determining a second load current and a second load voltage to the variable-load component while operating at the commanded second output. The method includes calculating a maximum power output of the thermoelectric generator from the determined first load current and voltage and the determined second load current and voltage, and commanding the variable-load component to operate at a third output. The commanded third output is configured to draw the calculated maximum power output from the thermoelectric generator.

  15. Method and means for a spatial and temporal probe for laser-generated plumes based on density gradients

    DOE Patents [OSTI]

    Yeung, Edward S. (Ames, IA); Chen, Guoying (Laramie, WY)

    1990-05-01

    A method and means for a spatial and temporal probe for laser generated plumes based on density gradients includes generation of a plume of vaporized material from a surface by an energy source. The probe laser beam is positioned so that the plume passes through the probe laser beam. Movement of the probe laser beam caused by refraction from the density gradient of the plume is monitored. Spatial and temporal information, correlated to one another, is then derived.

  16. Impact of load type on microgrid stability

    E-Print Network [OSTI]

    Monnin, Jared P

    2012-01-01

    Microgrids show great promise as a means of integrating distributed generation sources into the public grid distribution system. In order to provide uninterrupted,high quality power to local loads, microgrids must have the ...

  17. Protecting Consumer Privacy from Electric Load Stephen McLaughlin Patrick McDaniel

    E-Print Network [OSTI]

    McDaniel, Patrick Drew

    isolation and recovery, and support for alternative energy sources, e.g., consumer generated wind and solar as Non-Intrusive Load Monitoring (NILM): Load monitoring Load profile Lighting Oven Heater ... Appliance

  18. The dynamic response of edge clamped plates loaded by spherically expanding sand shellsq

    E-Print Network [OSTI]

    Wadley, Haydn

    The dynamic response of edge clamped plates loaded by spherically expanding sand shellsq Kumar P and water saturated sand has been investigated, both experimentally and via a particle based simulation methodology. The spherically expanding sand shell is generated by detonating a sphere of explosive surrounded

  19. Review of current Southern California edison load management programs and proposal for a new market-driven, mass-market, demand-response program

    E-Print Network [OSTI]

    Weller, G.H.

    2002-01-01

    Commercial & Industrial (C&I) Load Management Programs A.on the Existing SCE Load Management System / Technology BaseSmall Commercial Load Management Programs A. Programs based

  20. Spinning Reserve From Hotel Load Response: Initial Progress

    SciTech Connect (OSTI)

    Kueck, John D; Kirby, Brendan J

    2008-11-01

    This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

  1. Assumption-Based Planning: Generating Plans and Explanations under Incomplete Knowledge

    E-Print Network [OSTI]

    McIlraith, Sheila

    ) it captures a compelling form of commonsense planning, and 2) it is of great utility in the generation the utility of this new planning paradigm. Introduction Many real-world planning problems provide limited) it is of great utility for tasks that share a computational core with planning, such as explanation generation (e

  2. Frequency Synthesizers and Oscillator Architectures Based on Multi-Order Harmonic Generation 

    E-Print Network [OSTI]

    Abdul-Latif, Mohammed

    2012-02-14

    synthesizers. This architecture uses two-step multi-order harmonic generation of a low frequency phase-locked signal to generate wideband mm-wave frequencies. A prototype of the proposed system is designed and fabricated in 90nm Complementary Metal Oxide...

  3. Tunable optical parametric generator based on the pump spatial walk-off

    E-Print Network [OSTI]

    Cavanna, Andrea; Sharapova, Polina R; Taheri, Michael; Leuchs, Gerd; Chekhova, Maria V

    2015-01-01

    We suggest a novel optical parametric generator (OPG) in which one of the down-converted beams is spontaneously generated along the Poynting vector of the pump beam. In this configuration, the generation takes advantage of the walk-off of the extraordinary pump rather than being degraded by it. As a result the generated beams, signal and idler, are bright, due to a high conversion efficiency, spatially nearly single-mode, due to the preferred direction of the Poynting vector, tuneable over a wide range of wavelengths, and broadband. The two beams are also correlated in frequency and in the photon number per pulse. Furthermore due to their thermal statistics these beams can be used as a pump to efficiently generate other nonlinear processes.

  4. Generator of neutrino-nucleon interactions for the FLUKA based simulation code

    SciTech Connect (OSTI)

    Battistoni, G.; Sala, P. R. [INFN, Sezione di Milano, Via Celoria 16, 20133 Milan (Italy); Ferrari, A. [CERN, CH-1211 GENEVE 23 (Switzerland); Lantz, M. [RIKEN Nishina Center for Accelerator-Based Science, Wako (Japan); Smirnov, G. I. [CERN, CH-1211 GENEVE 23 (Switzerland); JINR, Dubna (Russian Federation)

    2009-11-25

    An event generator of neutrino-nucleon and neutrino-nucleus interactions has been developed for the general purpose Monte Carlo code FLUKA. The generator includes options for simulating quasi-elastic interactions, the neutrino-induced resonance production and deep inelastic scattering. Moreover, it shares the hadronization routines developed earlier in the framework of the FLUKA package for simulating hadron-nucleon interactions. The simulation of neutrino-nuclear interactions makes use of the well developed PEANUT event generator implemented in FLUKA for modeling of the interactions between hadrons and nuclei. The generator has been tested in the neutrino energy range from 0 to 10 TeV and it is available in the standard FLUKA distribution. Limitations related to some particular kinematical conditions are discussed. A number of upgrades is foreseen for the generator which will optimize its applications for simulating experiments in the CNGS beam.

  5. JOURNAL OF LIGHTWAVE TECHNOLOGY, VOL. 32, NO. 20, OCTOBER 15 2014 3637 Photonic Generation of Microwave Waveforms Based

    E-Print Network [OSTI]

    Yao, Jianping

    of Microwave Waveforms Based on a Polarization Modulator in a Sagnac Loop Weilin Liu, Student Member, IEEE, and Jianping Yao, Fellow, IEEE, Fellow, OSA Abstract--An optical microwave waveform generator using a polarization modulator (PolM) in a Sagnac loop is proposed and experimentally demonstrated. Microwave waveforms

  6. Practical and fast quantum random number generation based on photon arrival time relative to external reference

    SciTech Connect (OSTI)

    Nie, You-Qi; Zhang, Jun Pan, Jian-Wei; Zhang, Hong-Fei; Wang, Jian; Zhang, Zhen; Ma, Xiongfeng

    2014-02-03

    We present a practical high-speed quantum random number generator, where the timing of single-photon detection relative to an external time reference is measured as the raw data. The bias of the raw data can be substantially reduced compared with the previous realizations. The raw random bit rate of our generator can reach 109 Mbps. We develop a model for the generator and evaluate the min-entropy of the raw data. Toeplitz matrix hashing is applied for randomness extraction, after which the final random bits are able to pass the standard randomness tests.

  7. Generation-based memory synchronization in a multiprocessor system with weakly consistent memory accesses

    DOE Patents [OSTI]

    Ohmacht, Martin

    2014-09-09

    In a multiprocessor system, a central memory synchronization module coordinates memory synchronization requests responsive to memory access requests in flight, a generation counter, and a reclaim pointer. The central module communicates via point-to-point communication. The module includes a global OR reduce tree for each memory access requesting device, for detecting memory access requests in flight. An interface unit is implemented associated with each processor requesting synchronization. The interface unit includes multiple generation completion detectors. The generation count and reclaim pointer do not pass one another.

  8. Mesh Generator Matthew Hanlon

    E-Print Network [OSTI]

    Nebel, Jean-Christophe

    1 Mesh Generator Matthew Hanlon 9804817 hanlonmj@dsc.gla.ac.uk Class CS4H Session 2002 from two dimensional slices. Medical data stored as sets of slices can be used to generate a three was developed with the following requirements: · Load a set of slices into the system · Generate a mesh for each

  9. Reliable and efficient PUF-based key generation using pattern matching

    E-Print Network [OSTI]

    Paral, Zdenek (Sid)

    We describe a novel and efficient method to reliably provision and re-generate a finite and exact sequence of bits, for use with cryptographic applications, e.g., as a key, by employing one or more challengeable Physical ...

  10. Preliminary design and viability consideration of external, shroud-based stators in wind turbine generators

    E-Print Network [OSTI]

    Shoemaker-Trejo, Nathaniel (Nathaniel Joseph)

    2012-01-01

    Horizontal-axis wind turbine designs often included gearboxes or large direct-drive generators to compensate for the low peripheral speeds of the turbine hub. To take advantage of high blade tip speeds, an alternative ...

  11. Harvesting and summarizing user-generated content for advanced speech-based human-computer interaction

    E-Print Network [OSTI]

    Liu, Jingjing, Ph. D. Massachusetts Institute of Technology

    2012-01-01

    There have been many assistant applications on mobile devices, which could help people obtain rich Web content such as user-generated data (e.g., reviews, posts, blogs, and tweets). However, online communities and social ...

  12. Behaviour Generation in Humanoids by Learning Potential-based Policies from Constrained Motion 

    E-Print Network [OSTI]

    Howard, Matthew; Klanke, Stefan; Gienger, Michael; Goerick, Christian; Vijayakumar, Sethu

    Movement generation that is consistent with observed or demonstrated behaviour is an efficient way to seed movement planning in complex, high-dimensionalmovement systems like humanoid robots.We present a method for learning ...

  13. An evolution-based generative design system : using adaptation to shape architectural form

    E-Print Network [OSTI]

    Caldas, Luisa Gama (Maria Luisa da Oliveira Gama Caldas), 1968-

    2001-01-01

    This dissertation dwells in the interstitial spaces between the fields of architecture, environmental design and computation. It introduces a Generative Design System that draws on evolutionary concepts to incorporate ...

  14. Copula Based Stochastic Weather Generator as an Application for Crop Growth Models and Crop Insurance 

    E-Print Network [OSTI]

    Juarez Torres, Miriam 77-

    2012-08-31

    Stochastic Weather Generators (SWG) try to reproduce the stochastic patterns of climatological variables characterized by high dimensionality, non-normal probability density functions and non-linear dependence relationships. However, conventional...

  15. An air-breathing, portable thermoelectric power generator based on a microfabricated silicon combustor

    E-Print Network [OSTI]

    Marton, Christopher Henry

    2011-01-01

    The global consumer demand for portable electronic devices is increasing. The emphasis on reducing size and weight has put increased pressure on the power density of available power storage and generation options, which ...

  16. Machine Learning Approach to Islanding Detection for Inverter-Based Distributed Generation 

    E-Print Network [OSTI]

    Matic Cuka, Biljana

    2014-12-17

    Despite a number of economic and environmental benefits that integration of renewable distributed generation (DG) into the distribution grid brings, there are many technical challenges that arise as well. One of the most important issues concerning...

  17. Distributed Frequency-Preserving Optimal Load Control

    E-Print Network [OSTI]

    Wierman, Adam

    Distributed Frequency-Preserving Optimal Load Control Enrique Mallada Steven H. Low California prices to incentivize the users to adapt their consumption to the true cost of generation at the time to accept more readily a stochastically fluctuating energy source, such as wind or solar generation

  18. Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide

    SciTech Connect (OSTI)

    Kim, Kyung-Rok; Kim, Kyung-Soo Kim, Soohyun

    2014-07-15

    This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.

  19. Load Management for Industry 

    E-Print Network [OSTI]

    Konsevick, W. J., Jr.

    1982-01-01

    categories: Thermal Energy Storage, Communication and Load Control, Interconnection and Operation of Power Systems, and Selective Load Promotions. The endeavors of the utility industry and Ohio Edison Company in three of the four categories are described...

  20. Load sensing system

    DOE Patents [OSTI]

    Sohns, Carl W. (Oak Ridge, TN); Nodine, Robert N. (Knoxville, TN); Wallace, Steven Allen (Knoxville, TN)

    1999-01-01

    A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast

  1. Bayesian Belief Network (BBN)-based advisory system development for steam generator replacement project management

    E-Print Network [OSTI]

    Kim, Dohyoung, 1970-

    2002-01-01

    The growing need for improved project management technique points to the usefulness of a knowledge-base advisory system to help project managers understand current and future project status and optimize decisions based ...

  2. Prognostic Control and Load Survivability in Shipboard Power Systems 

    E-Print Network [OSTI]

    Thomas, Laurence J.

    2011-02-22

    bus. Generators 2MTG and 2ATG work together to energize loads connected to the port bus. The Forward/Aft Split Bus Mode separates the generators in half forming a left-hand region (fore) and a right hand-region (aft) pairing generators 1MTG and 2... is to maximize the energized loads in case there is a disturbance adhering to constraints of the source node, load node, intermediate node, edge capacity, radiality, and voltage. The results display the capacities of each load and the new path taken to supply...

  3. Web-Based Method to Generate Specific Energy Consumption Data for the Evaluation and Optimization of Building Operation 

    E-Print Network [OSTI]

    Wagner, A.; Wambsgan, M.; Froehlich, S.

    2004-01-01

    University Karlsruhe (TH) - Department of Architecture Building Physics and Technical Building Services web-based method to generate specific energyconsumption data for the evaluation and optimisationof building operationAndreas Wagner, Mathias... about energy consumptionand specific data especially in large building stocks?user complaints and energy consumption arerarely considered in building operation?reduction of energy consumption and operation costsas well as ensuring a high work space...

  4. Instituto Nacional de Electrification, Guatemala Load Dispatch Center and Global Communications Center. Feasibility report (Instituto Nacional de Electrificacion, Guatemala Centro Nacional de Despacho de Carga y Sistema Global de Comunicaciones). Export trade information

    SciTech Connect (OSTI)

    Not Available

    1985-07-01

    The report presents the results of a feasibility study for the National Load Dispatch Center and Global Communications System Project in Guatemala. The project consists of a communication system which will provide Institute Nacional de Electrificacion (INDE) operations personnel direct voice access to all major power system facilities. In addition, a modern computer based load dispatch center has been configured on a secure and reliable basis to provide automatic generation control of all major interconnected generating plants within Guatemala.

  5. Effect of K loadings on nitrate formation/decomposition and on NOx storage performance of K-based NOx storage-reduction catalysts

    SciTech Connect (OSTI)

    Kim, Do Heui; Mudiyanselage, Kumudu K.; Szanyi, Janos; Kwak, Ja Hun; Zhu, Haiyang; Peden, Charles HF

    2013-10-25

    We have investigated nitrate formation and decomposition processes, and measured NOx storage performance on Pt-K2O/Al2O3 catalysts as a function of potassium loading. After NO2 adsorption at room temperature, ionic and bidentate nitrates were observed by fourier transform infra-red (FTIR) spectroscopy. The ratio of the former to the latter species increased with increasing potassium loading up to 10 wt%, and then stayed almost constant with additional K, demonstrating a clear dependence of loading on the morphology of the K species. Although both K2O(10)/Al2O3 and K2O(20)/Al2O3 samples have similar nitrate species after NO2 adsorption, the latter has more thermally stable nitrate species as evidenced by FTIR and NO2 temperature programmed desorption (TPD) results. With regard to NOx storage performance, the temperature of maximum NOx uptake (Tmax) is 573 K up to a potassium loading of 10 wt%. As the potassium loading increases from 10 wt% to 20 wt%, Tmax shifted from 573 K to 723 K. Moreover, the amount of NO uptake (38 cm3 NOx/g catal) at Tmax increased more than three times, indicating that efficiency of K in storing NOx is enhanced significantly at higher temperature, in good agreement with the NO2 TPD and FTIR results. Thus, a combination of characterization and NOx storage performance results demonstrates an unexpected effect of potassium loading on nitrate formation and decomposition processes; results important for developing Pt-K2O/Al2O3 for potential applications as high temperature NOx storage-reduction catalysts.

  6. SE-72/AS-72 generator system based on Se extraction/ As reextraction

    DOE Patents [OSTI]

    Fassbender, Michael Ernst; Ballard, Beau D

    2013-09-10

    The preparation of a .sup.72Se/.sup.72As radioisotope generator involves forming an acidic aqueous solution of an irradiated alkali bromide target such as a NaBr target, oxidizing soluble bromide in the solution to elemental bromine, removing the elemental bromine, evaporating the resulting solution to a residue, removing hydrogen chloride from the residue, forming an acidic aqueous solution of the residue, adding a chelator that selectively forms a chelation complex with selenium, and extracting the chelation complex from the acidic aqueous solution into an organic phase. As the .sup.72Se generates .sup.72As in the organic phase, the .sup.72As may be extracted repeatedly from the organic phase with an aqueous acid solution.

  7. Isotopic generator for bismuth-212 and lead-212 based on radium

    DOE Patents [OSTI]

    Hines, J.J.; Atcher, R.W.; Friedman, A.M.

    1985-01-30

    Disclosed are method and apparatus for providing radionuclides of bismuth-212 and lead-212. Thorium-228 and carrier solution starting material is input to a radiologically contained portion of an isotopic generator system, and radium-224 is separated from thorium-228 which is retained by a strongly basic anion exchange column. The separated radium-224 is transferred to an accessible, strongly acidic cationic exchange column. The cationic column retains the radium-224, and natural radioactive decay generates bismuth-212 and lead-212. The cationic exchange column can also be separated from the contained portion of the system and utilized without the extraordinary safety measures necessary in the contained portion. Furthermore, the cationic exchange column provides over a relatively long time period the short lived lead-212 and bismuth-212 radionuclides which are useful for a variety of medical therapies.

  8. Hydrogen Gas Generation Model for Fuel Based Remote Handled TRU Waste Stored at INEEL

    SciTech Connect (OSTI)

    Soli T. Khericha; Rajiv N. Bhatt; Kevin Liekhus

    2003-02-01

    The Idaho National Environmental and Engineering Laboratory (INEEL) initiated efforts to calculate the hydrogen gas generation in remote-handled transuranic (RH-TRU) containers in order to evaluate continued storage of unvented RH-TRU containers in vaults and to identify any potential problems during retrieval and aboveground storage. A computer code is developed to calculate the hydrogen concentration in the stored RH-TRU waste drums for known configuration, waste matrix, and radionuclide inventories as a function of time.

  9. Effect of Large Scale Transmission Limitations on Renewable Energy Load Matching for Western U.S.: Preprint

    SciTech Connect (OSTI)

    Diakov, V.; Short, W.; Gilchrist, B.

    2012-06-01

    Based on the available geographically dispersed data for the Western U.S. (excluding Alaska), we analyze to what extent the geographic diversity of these resources can offset their variability. Without energy storage and assuming unlimited energy flows between regions, wind and PV can meet up to 80% of loads in Western U.S. while less than 10% of the generated power is curtailed. Limiting hourly energy flows by the aggregated transmission line carrying capacities decreases the fraction of the load that can be met with wind and PV generation to approximately 70%.

  10. Alternative methods of modeling wind generation using production cost models

    SciTech Connect (OSTI)

    Milligan, M.R. [National Renewable Energy Lab., Golden, CO (United States)] [National Renewable Energy Lab., Golden, CO (United States); Pang, C.K. [P Plus Corp., Cupertino, CA (United States)] [P Plus Corp., Cupertino, CA (United States)

    1996-08-01

    This paper examines the methods of incorporating wind generation in two production costing models: one is a load duration curve (LDC) based model and the other is a chronological-based model. These two models were used to evaluate the impacts of wind generation on two utility systems using actual collected wind data at two locations with high potential for wind generation. The results are sensitive to the selected wind data and the level of benefits of wind generation is sensitive to the load forecast. The total production cost over a year obtained by the chronological approach does not differ significantly from that of the LDC approach, though the chronological commitment of units is more realistic and more accurate. Chronological models provide the capability of answering important questions about wind resources which are difficult or impossible to address with LDC models.

  11. FPGA Based Sinusoidal Pulse Width Modulated Waveform Generation for Solar (PV) Rural Home Power Inverter

    E-Print Network [OSTI]

    Singh, S N

    2010-01-01

    With the increasing concern about global environmental protection and energy demand due to rapid growth of population in developing countries and the diminishing trend of resources of conventional grid supply, the need to produce freely available pollution free natural energy such as solar/wind energy has been drawing increasing interest in every corner of the world. In an effort to utilize these energies effectively through Power converter, a great deal of research is being carried out by different researchers / scientist and engineers at different places in the world to meet the increasing demand of load. The study presents methodology to integrate solar (PV) energy (which is freely available in every corner of the world) with grid source and supplement the existing grid power in rural houses during its cut off or restricted supply period. In order to get consistency in supply a DG is also added as a standby source in the proposed integration of network. The software using novel Direct PWM modulation strate...

  12. Removal of Filter Cake Generated by Manganese Tetraoxide Water-based Drilling Fluids 

    E-Print Network [OSTI]

    Al Mojil, Abdullah Mohammed A.

    2011-10-21

    Three effective solutions to dissolve the filter cake created by water-based drilling fluids weighted with Mn3O4 particles were developed. Hydrochloric acid at concentration lower than 5 wt% can dissolve most of Mn3O4-based filter cake. Dissolving...

  13. Challenges and Opportunities for Compound Semiconductor Devices in Next Generation Wireless Base Station Power Amplifiers

    E-Print Network [OSTI]

    Asbeck, Peter M.

    Station Power Amplifiers Lawrence Larson, Peter Asbeck, and Donald Kimball Center for Wireless Communications, Dept of ECE, UCSD, La Jolla, CA 92093 Abstract -- Power Amplifiers for cellular base stations their networks to 3G services in the coming years, it is expected that the market for base station power

  14. GENERATING PITCH ACCENTS IN A CONCEPT-TO-SPEECH SYSTEM USING A KNOWLEDGE BASE

    E-Print Network [OSTI]

    Williams, Sandra

    requiring particular emphasis or stress. Our pitch accenting algorithm uses a domain knowledge base the placement of pitch accents on syllables requiring particular emphasis or stress in an utterance, the subject labour intensive. However, we have demonstrated that a large knowledge base can be built automatically

  15. The Role of Logic Programming in NextGeneration ComponentBased Software Development

    E-Print Network [OSTI]

    Lau, Kung-Kiu

    ) lies in the so­called Industrial Revolution for Information Technology --- Component­based Software Development (CBD). 2 CBD --- ``The Next Industrial Revolution'' Component­based Software Development (CBD) has been hailed as the ``Industrial Revolution for IT''! This ``rev­ olution'' aims at delivering Software

  16. Catheter based mid-infrared reflectance and reflectance generated absorption spectroscopy

    DOE Patents [OSTI]

    Holman, Hoi-Ying N

    2013-10-29

    A method of characterizing conditions in a tissue, by (a) providing a catheter that has a light source that emits light in selected wavenumbers within the range of mid-IR spectrum; (b) directing the light from the catheter to an area of tissue at a location inside a blood vessel of a subject; (c) collecting light reflected from the location and generating a reflectance spectra; and (d) comparing the reflectance spectra to a reference spectra of normal tissue, whereby a location having an increased number of absorbance peaks at said selected wavenumbers indicates a tissue inside the blood vessel containing a physiological marker for atherosclerosis.

  17. Inference-based Geometric Modeling for the Generation of Complex Cluttered Virtual Environments 

    E-Print Network [OSTI]

    Biggers, Keith Edward

    2012-07-16

    . : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 2 2 Surface splatting applied to a point cloud dataset. : : : : : : : : : : : 3 3 Moving Least Squares and contouring applied to a point cloud dataset. 4 4 Our solid modeling algorithm applied to a point cloud dataset. : : : 5 5 Overview... scanner-based point cloud of a cluttered environment. : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 19 11 An example of a photo-based point cloud of a cluttered environment. 19 12 Point cloud samples and tted surface splats...

  18. Chaotic oscillation and random-number generation based on nanoscale optical-energy transfer

    E-Print Network [OSTI]

    Naruse, Makoto; Aono, Masashi; Hori, Hirokazu; Ohtsu, Motoichi

    2014-01-01

    By using nanoscale energy-transfer dynamics and density matrix formalism, we demonstrate theoretically and numerically that chaotic oscillation and random-number generation occur in a nanoscale system. The physical system consists of a pair of quantum dots (QDs), with one QD smaller than the other, between which energy transfers via optical near-field interactions. When the system is pumped by continuous-wave radiation and incorporates a timing delay between two energy transfers within the system, it emits optical pulses. We refer to such QD pairs as nano-optical pulsers (NOPs). Irradiating an NOP with external periodic optical pulses causes the oscillating frequency of the NOP to synchronize with the external stimulus. We find that chaotic oscillation occurs in the NOP population when they are connected by an external time delay. Moreover, by evaluating the time-domain signals by statistical-test suites, we confirm that the signals are sufficiently random to qualify the system as a random-number generator (R...

  19. Chaotic oscillation and random-number generation based on nanoscale optical-energy transfer

    E-Print Network [OSTI]

    Makoto Naruse; Song-Ju Kim; Masashi Aono; Hirokazu Hori; Motoichi Ohtsu

    2014-12-19

    By using nanoscale energy-transfer dynamics and density matrix formalism, we demonstrate theoretically and numerically that chaotic oscillation and random-number generation occur in a nanoscale system. The physical system consists of a pair of quantum dots (QDs), with one QD smaller than the other, between which energy transfers via optical near-field interactions. When the system is pumped by continuous-wave radiation and incorporates a timing delay between two energy transfers within the system, it emits optical pulses. We refer to such QD pairs as nano-optical pulsers (NOPs). Irradiating an NOP with external periodic optical pulses causes the oscillating frequency of the NOP to synchronize with the external stimulus. We find that chaotic oscillation occurs in the NOP population when they are connected by an external time delay. Moreover, by evaluating the time-domain signals by statistical-test suites, we confirm that the signals are sufficiently random to qualify the system as a random-number generator (RNG). This study reveals that even relatively simple nanodevices that interact locally with each other through optical energy transfer at scales far below the wavelength of irradiating light can exhibit complex oscillatory dynamics. These findings are significant for applications such as ultrasmall RNGs.

  20. Battery-free Wireless Sensor Network For Advanced Fossil-Fuel Based Power Generation

    SciTech Connect (OSTI)

    Yi Jia

    2011-02-28

    This report summarizes technical progress achieved during the project supported by the Department of Energy under Award Number DE-FG26-07NT4306. The aim of the project was to conduct basic research into battery-free wireless sensing mechanism in order to develop novel wireless sensors and sensor network for physical and chemical parameter monitoring in a harsh environment. Passive wireless sensing platform and five wireless sensors including temperature sensor, pressure sensor, humidity sensor, crack sensor and networked sensors developed and demonstrated in our laboratory setup have achieved the objective for the monitoring of various physical and chemical parameters in a harsh environment through remote power and wireless sensor communication, which is critical to intelligent control of advanced power generation system. This report is organized by the sensors developed as detailed in each progress report.

  1. HLW Glass Waste Loadings

    Office of Environmental Management (EM)

    HLW Glass Waste Loadings Ian L. Pegg Vitreous State Laboratory The Catholic University of America Washington, DC Overview Overview Vitrification - general background Joule...

  2. Load sensing system

    DOE Patents [OSTI]

    Sohns, C.W.; Nodine, R.N.; Wallace, S.A.

    1999-05-04

    A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast inventories of stored nuclear material can be continuously monitored and inventoried of minimal cost. 4 figs.

  3. Control of Electro-Rheological Fluid Based Torque Generation Components For Use in Active Rehabilitation Devices

    E-Print Network [OSTI]

    Mavroidis, Constantinos

    a gear system is connected. The key features of AKROD include: a compact, lightweight design with highly we present the design and control algorithms for novel electro-rheological fluid based torque-rheological fluid (ERF) element that connects to the output of the gear system. Using the electrically controlled

  4. On Constructing a Base Map for Collaborative Map Generation and its Application in Urban Mobility Planning

    E-Print Network [OSTI]

    planning depends largely on the presence of good navigation data in the form of vectorized maps countries. On the other hand, good paper maps collected by the city authorities are widely available. Nevertheless, the integration of these GPS traces is itself a challenge and requires a good base map

  5. Automatic Generation of Virtual Cities Based on User Defined Zoning Districts 

    E-Print Network [OSTI]

    Van Maanen, Kathryn Elizabeth

    2012-07-16

    .1. Design Laws and Guidelines for the Com- mercial District . . . . . . . . . . . . . . . . . 29 III.3.2. Common Building Characteristics of the Commercial District . . . . . . . . . . . . . . 30 III.4. O ce District... downtown[3]. : : : : : : : : : : : : : : : 37 26 Base shapes for O ce District building library : : : : : : : : : : : : : 39 27 Example of selection sets of faces for O ce Building 1 : : : : : : : : 39 28 Example of selection sets of faces for O ce...

  6. Linear demultiple solution based on bottom-multiple generator (BMG) approximation: subsalt example 

    E-Print Network [OSTI]

    Oladeinde, Abiola Omobolaji

    2006-10-30

    ............................................................. 12 Radon Transform ................................................ 14 Demultiple Technique Based on Prediction and Subtraction .................................................................. 14 Inverse Scattering Multiple Attenuation... common midpoint (CMP) stacking, frequency ? wave number (f-k) filter and radon transform. The second broad group is the wavefield prediction and subtraction technique. Demultiple techniques under the group are the wavefield...

  7. Spinning Reserve From Responsive Loads

    SciTech Connect (OSTI)

    Kirby, B.J.

    2003-04-08

    Responsive load is the most underutilized reliability resource available to the power system today. It is currently not used at all to provide spinning reserve. Historically there were good reasons for this, but recent technological advances in communications and controls have provided new capabilities and eliminated many of the old obstacles. North American Electric Reliability Council (NERC), Federal Energy Regulatory Commission (FERC), Northeast Power Coordinating Council (NPCC), New York State Reliability Council (NYSRC), and New York Independent System Operator (NYISO) rules are beginning to recognize these changes and are starting to encourage responsive load provision of reliability services. The Carrier ComfortChoice responsive thermostats provide an example of these technological advances. This is a technology aimed at reducing summer peak demand through central control of residential and small commercial air-conditioning loads. It is being utilized by Long Island Power Authority (LIPA), Consolidated Edison (ConEd), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E). The technology is capable of delivering even greater response in the faster spinning reserve time frame (while still providing peak reduction). Analysis of demand reduction testing results from LIPA during the summer of 2002 provides evidence to back up this claim. It also demonstrates that loads are different from generators and that the conventional wisdom, which advocates for starting with large loads as better ancillary service providers, is flawed. The tempting approach of incrementally adapting ancillary service requirements, which were established when generators were the only available resources, will not work. While it is easier for most generators to provide replacement power and non-spinning reserve (the slower response services) than it is to supply spinning reserve (the fastest service), the opposite is true for many loads. Also, there is more financial reward for supplying spinning reserve than for supplying the other reserve services as a result of the higher spinning reserve prices. The LIPAedge program (LIPA's demand reduction program using Carrier ComfortChoice thermostats) provides an opportunity to test the use of responsive load for spinning reserve. With potentially 75 MW of spinning reserve capability already installed, this test program can also make an important contribution to the capacity needs of Long Island during the summer of 2003. Testing could also be done at ConEd ({approx}30 MW), SCE ({approx}15 MW), and/or SDG&E ({approx}15 MW). This paper is divided into six chapters. Chapter 2 discusses the contingency reserve ancillary services, their functions in supporting power system reliability, and their technical requirements. It also discusses the policy and tariff requirements and attempts to distinguish between ones that are genuinely necessary and ones that are artifacts of the technologies that were historically used to provide the services. Chapter 3 discusses how responsive load could provide contingency reserves (especially spinning reserve) for the power system. Chapter 4 specifically discusses the Carrier ComfortChoice responsive thermostat technology, the LIPAedge experience with that technology, and how the technology could be used to supply spinning reserve. Chapter 5 discusses a number of unresolved issues and suggests areas for further research. Chapter 6 offers conclusions and recommendations.

  8. Next-Generation Liquid-Scintillator-Based Detectors: Quantums Dots and Picosecond Timing

    E-Print Network [OSTI]

    Lindley Winslow

    2013-07-10

    Liquid-scintillator-based detectors are a robust technology that scales well to large volumes. For this reason, they are attractive for experiments searching for neutrinoless double-beta decay. A combination of improved photo-detection technology and novel liquid scintillators may allow for the extraction of particle direction in addition to the total energy of the particle. Such an advance would find applications beyond searches for neutrinoless double-beta decay.

  9. Utility Solar Generation Valuation Methods

    SciTech Connect (OSTI)

    Hansen, Thomas N.; Dion, Phillip J.

    2009-06-30

    Tucson Electric Power (TEP) developed, tested and verified the results of a new and appropriate method for accurately evaluating the capacity credit of time variant solar generating sources and reviewed new methods to appropriately and fairly evaluate the value of solar generation to electric utilities. The project also reviewed general integrated approaches for adequately compensating owners of solar generation for their benefits to utilities. However, given the limited funding support and time duration of this project combined with the significant differences between utilities regarding rate structures, solar resource availability and coincidence of solar generation with peak load periods, it is well beyond the scope of this project to develop specific rate, rebate, and interconnection approaches to capture utility benefits for all possible utilities. The project developed computer software based evaluation method models to compare solar generation production data measured in very short term time increments called Sample Intervals over a typical utility Dispatch Cycle during an Evaluation Period against utility system load data. Ten second resolution generation production data from the SGSSS and actual one minute resolution TEP system load data for 2006 and 2007, along with data from the Pennington Street Garage 60 kW DC capacity solar unit installed in downtown Tucson will be applied to the model for testing and verification of the evaluation method. Data was provided by other utilities, but critical time periods of data were missing making results derived from that data inaccurate. The algorithms are based on previous analysis and review of specific 2005 and 2006 SGSSS production data. The model was built, tested and verified by in house TEP personnel. For this phase of the project, TEP communicated with, shared solar production data with and collaborated on the development of solar generation valuation tools with other utilities, including Arizona Public Service, Salt River Project, Xcel and Nevada Power Company as well as the Arizona electric cooperatives. In the second phase of the project, three years of 10 second power output data of the SGSSS was used to evaluate the effectiveness of frequency domain analysis, normal statistical distribution analysis and finally maximum/minimum differential output analysis to test the applicability of these mathematic methods in accurately modeling the output variations produced by clouds passing over the SGSSS array.

  10. Swing Dynamics as Primal-Dual Algorithm for Optimal Load Control

    E-Print Network [OSTI]

    Low, Steven H.

    al. studied the aggregate response character- istics when individual loads are turned on networks, loads can pro- vide flexible, fast responsive, and decentralized sources for frequency regulation and generation-demand balancing, com- plementary to generation control. We consider an optimal load control (OLC

  11. Case History of Reapplication of a 2500 KW Steam Turbine/Gear Drive Generator 

    E-Print Network [OSTI]

    Smith, S.

    1991-01-01

    OF REAPPLICATION OF A 2500 KW STEAM TURBINE/GEAR DRIVE GENERATOR SAMUEL V. SMITH Manager, Technical Sales and ~ervice Revak Turbomachinery SerVlces La Porte, Texas Abstract In today' s equipment market more and more projects are turning toward..., naphtha and a high grade of wax. The plant requires a steam turbine generator set to produce electrical power for its base load operation. This paper covers the history of how the turbine, gear and generator were selected, along with the highlights...

  12. Sulfur Based Thermochemical Heat Storage for Baseload Concentrated Solar Power Generation

    SciTech Connect (OSTI)

    wong, bunsen

    2014-11-20

    This project investigates the engineering and economic feasibility of supplying baseload power using a concentrating solar power (CSP) plant integrated with sulfur based thermochemical heat storage. The technology stores high temperature solar heat in the chemical bonds of elemental sulfur. Energy is recovered as high temperature heat upon sulfur combustion. Extensive developmental and design work associated with sulfur dioxide (SO2) disproportionation and sulfuric acid (H2SO4) decomposition chemical reactions used in this technology had been carried out in the two completed phases of this project. The feasibility and economics of the proposed concept was demonstrated and determined.

  13. Development of a New Generation, High Efficiency PEM Fuel Cell Based, CHP

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum Based| Department8,Department of Energy2 DOE Hydrogen andMEQ in EGSMEQSystem

  14. S-Band Loads for SLAC Linac

    SciTech Connect (OSTI)

    Krasnykh, A.; Decker, F.-J.; /SLAC; LeClair, R.; /INTA Technologies, Santa Clara

    2012-08-28

    The S-Band loads on the current SLAC linac RF system were designed, in some cases, 40+ years ago to terminate 2-3 MW peak power into a thin layer of coated Kanthal material as the high power absorber [1]. The technology of the load design was based on a flame-sprayed Kanthal wire method onto a base material. During SLAC linac upgrades, the 24 MW peak klystrons were replaced by 5045 klystrons with 65+ MW peak output power. Additionally, SLED cavities were introduced and as a result, the peak power in the current RF setup has increased up to 240 MW peak. The problem of reliable RF peak power termination and RF load lifetime required a careful study and adequate solution. Results of our studies and three designs of S-Band RF load for the present SLAC RF linac system is discussed. These designs are based on the use of low conductivity materials.

  15. Connectivity-based, all-hexahedral mesh generation method and apparatus

    DOE Patents [OSTI]

    Tautges, T.J.; Mitchell, S.A.; Blacker, T.D.; Murdoch, P.

    1998-06-16

    The present invention is a computer-based method and apparatus for constructing all-hexahedral finite element meshes for finite element analysis. The present invention begins with a three-dimensional geometry and an all-quadrilateral surface mesh, then constructs hexahedral element connectivity from the outer boundary inward, and then resolves invalid connectivity. The result of the present invention is a complete representation of hex mesh connectivity only; actual mesh node locations are determined later. The basic method of the present invention comprises the step of forming hexahedral elements by making crossings of entities referred to as ``whisker chords.`` This step, combined with a seaming operation in space, is shown to be sufficient for meshing simple block problems. Entities that appear when meshing more complex geometries, namely blind chords, merged sheets, and self-intersecting chords, are described. A method for detecting invalid connectivity in space, based on repeated edges, is also described, along with its application to various cases of invalid connectivity introduced and resolved by the method. 79 figs.

  16. New Generation of MoSx Based Solid Lubricant Coatings: Recent Developments and Applications

    SciTech Connect (OSTI)

    Haider, Julfikar; Hashmi, M. S. J.

    2011-01-17

    In recent times, there is a growing interest in applying Molybdenum disulphide (MoS{sub x}) solid lubricant coatings on components to improve the tribological performance (i.e. lower friction coefficient and wear rate). The tribological performance of MoS{sub x} coating is strongly dependent on coating properties and tribological environment. MoS{sub x} coatings are highly successful in certain applications such as in space/vacuum technology, but its effectiveness is questioned in other terrestrial applications such as in cutting tool industry due to its lower hardness and poor oxidation resistance leading to shorter life. In order to circumvent this drawback, the paper identifies that current research is being concentrated on developing MoS{sub x} based coatings using three different approaches: (1) Metal or compound addition in MoS{sub x} coating (2)MoS{sub x} layer on hard coating and (3)MoS{sub x} addition in hard coating matrix. Although the primary objective is same in all three cases, the third approach is considered to be more effective in improving the tribological properties of the coating. Finally, the potential applications of MoS{sub x} based coatings in different industrial sectors have been briefly outlined.

  17. Mode-hopping mechanism generating colored noise in a magnetic tunnel junction based spin torque oscillator

    SciTech Connect (OSTI)

    Sharma, Raghav; Dürrenfeld, P.; Iacocca, E.; Heinonen, O. G.; Åkerman, J.; Muduli, P. K.

    2014-09-29

    The frequency noise spectrum of a magnetic tunnel junction based spin torque oscillator is examined where multiple modes and mode-hopping events are observed. The frequency noise spectrum is found to consist of both white noise and 1/f frequency noise. We find a systematic and similar dependence of both white noise and 1/f frequency noise on bias current and the relative angle between the reference and free layers, which changes the effective damping and hence the mode-hopping behavior in this system. The frequency at which the 1/f frequency noise changes to white noise increases as the free layer is aligned away from the anti-parallel orientation w.r.t the reference layer. These results indicate that the origin of 1/f frequency noise is related to mode-hopping, which produces both white noise as well as 1/f frequency noise similar to the case of ring lasers.

  18. arXiv:1307.1718v1[cs.IR]5Jul2013 Graph-based Approach to Automatic Taxonomy Generation (GraBTax)

    E-Print Network [OSTI]

    Giles, C. Lee

    arXiv:1307.1718v1[cs.IR]5Jul2013 Graph-based Approach to Automatic Taxonomy Generation (Gra in optimizing the structure of the taxonomy. To automatically generate topic-dependent taxonomies from a large with Wikipedia categories. 1 Introduction A taxonomy organizes concepts into a hierarchical structure, where

  19. Development of Novel Nanocrystal-based Solar Cell to Exploit Multiple Exciton Generation: Cooperative Research and Development Final Report, CRADA Number CRD-07-00227

    SciTech Connect (OSTI)

    Ellingson, R.

    2010-08-01

    The purpose of the project was to develop new design and fabrication techniques for NC solar cells with the goal of demonstrating enhanced photocurrent and efficiency by exploiting multiple exciton generation and to investigate multiple exciton generation and charge carrier dynamics in semiconductor NC films used in NC-based solar cells.

  20. Modality Effects on Cognitive Load and Performance in High-Load Information Presentation

    E-Print Network [OSTI]

    Theune, Mariët

    INTRODUCTION Intelligent human-computer interfaces are often multimodal, i.e. the human-computer communications into the modality planning procedure for systems that support high-load human-computer interaction. Author Keywords-load information presenta- tion scenario. Mainly based on modality-related psychology theories, we selected five

  1. Towards Next Generation TATB-based Explosives by Understanding Voids and Microstructure from 10 nm to 1 cm

    SciTech Connect (OSTI)

    Willey, T M; Overturf, G

    2009-03-26

    TATB-based explosives have been investigated on length scales spanning several orders of magnitude, from just under 10 nm to larger than 1 cm. This has been accomplished using a combination of ultra-small angle x-ray scattering (USAXS), ultra-small angle neutron scattering (USANS), and x-ray computed tomography (XRCT). USAXS determines distributions the smallest structures including hot-spot voids from hundreds of nanometers to a few microns, USANS extends this range to about 10 microns, and two variants of XRCT cover sizes from microns to centimeters. Several examples are presented for LX-17, a triaminotrinitrobenzene based plastic bonded explosive using Kel-F 800. As an extension of previous USAXS results, in these proceedings, an alternate binder results in a more uniform microstructure for the PBX, useful towards design of next-generation TATB-based explosives. These data are an important step to understanding microstructural mechanisms that affect the mechanical properties of TATB-based explosives, and provide complete a comprehensive characterization of the structure of LX-17 from nanometers to centimeters that can be used as empirical input to computational models of detonation, and in determining the relationship between voids and microstructure to detonation properties.

  2. Elevated Temperature Materials for Power Generation and Propulsion The energy industry is designing higher-efficiency land-based turbines for natural gas-fired

    E-Print Network [OSTI]

    Nair, Sankar

    higher-efficiency land-based turbines for natural gas-fired power generation systems. The high inlet is significant for modeling cyclic deformation in directionally solidified and single crystal turbine blades

  3. Next Generation Print-based Manufacturing for Photovoltaics and Solid State Lighting

    SciTech Connect (OSTI)

    Sue A. Carter

    2012-09-07

    For the grand challenge of reducing our energy and carbon footprint, the development of renewable energy and energy efficient technologies offer a potential solution. Energy technologies can reduce our dependence on foreign oil as well as the energy consumed by the petroleum industry, the leading consumer of energy by a U.S. industry sector. Nonetheless, the manufacturing processes utilized to manufacture equipment for alternative energy technologies often involve energy-intensive processes. This undermines some of the advantages to moving to 'green' technologies in the first place. Our answer to the Industrial Technology Program's (ITP) Grand Challenge FOA was to develop a transformational low cost manufacturing process for plastic-based photovoltaics that will lower by over 50% both energy consumption and greenhouse emissions and offer a return-of-investment of over 20%. We demonstrated a Luminescent Solar Concentrator fabricated on a plastic acrylic substrate (i.e. no glass) that increases the power output of the PV cell by 2.2x with a 2% power efficiency as well as an LSC with a 7% power efficiency that increased the power output from the PV cells by 35%. S large area 20-inch x 60-inch building-integrated photovoltaic window was fabricated using contract manufacturing with a 4% power efficiency which improved the power output of the PV cell by over 50%. In addition, accelerated lifetimes of the luminescent material demonstrate lifetimes of 20-years.

  4. A loaded thermoacoustic engine

    SciTech Connect (OSTI)

    Olson, J.R.; Swift, G.W.

    1995-11-01

    Measurements and analysis of the performance of a thermoacoustic engine driving a dissipative load are presented. The effect of the load can be explained qualitatively using a simple low-amplitude approximation and quantitatively by invoking a more accurate low-amplitude numerical solution. The heater power {ital @};DQ and hot-end temperature {ital T}{sub {ital H}} are found to be simple functions of the load impedance and the unloaded values of {ital @};DQ and {ital T}{sub {ital H}}. {copyright} {ital 1995} {ital Acoustical} {ital Society} {ital of} {ital America}.

  5. Load research manual. Volume 3. Load research for advanced technologies

    SciTech Connect (OSTI)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. The manual includes guides to load research literature and glossaries of load research and statistical terms. In Volume 3, special load research procedures are presented for solar, wind, and cogeneration technologies.

  6. SU-E-T-395: Multi-GPU-Based VMAT Treatment Plan Optimization Using a Column-Generation Approach

    SciTech Connect (OSTI)

    Tian, Z; Shi, F; Jia, X; Jiang, S; Peng, F

    2014-06-01

    Purpose: GPU has been employed to speed up VMAT optimizations from hours to minutes. However, its limited memory capacity makes it difficult to handle cases with a huge dose-deposition-coefficient (DDC) matrix, e.g. those with a large target size, multiple arcs, small beam angle intervals and/or small beamlet size. We propose multi-GPU-based VMAT optimization to solve this memory issue to make GPU-based VMAT more practical for clinical use. Methods: Our column-generation-based method generates apertures sequentially by iteratively searching for an optimal feasible aperture (referred as pricing problem, PP) and optimizing aperture intensities (referred as master problem, MP). The PP requires access to the large DDC matrix, which is implemented on a multi-GPU system. Each GPU stores a DDC sub-matrix corresponding to one fraction of beam angles and is only responsible for calculation related to those angles. Broadcast and parallel reduction schemes are adopted for inter-GPU data transfer. MP is a relatively small-scale problem and is implemented on one GPU. One headand- neck cancer case was used for test. Three different strategies for VMAT optimization on single GPU were also implemented for comparison: (S1) truncating DDC matrix to ignore its small value entries for optimization; (S2) transferring DDC matrix part by part to GPU during optimizations whenever needed; (S3) moving DDC matrix related calculation onto CPU. Results: Our multi-GPU-based implementation reaches a good plan within 1 minute. Although S1 was 10 seconds faster than our method, the obtained plan quality is worse. Both S2 and S3 handle the full DDC matrix and hence yield the same plan as in our method. However, the computation time is longer, namely 4 minutes and 30 minutes, respectively. Conclusion: Our multi-GPU-based VMAT optimization can effectively solve the limited memory issue with good plan quality and high efficiency, making GPUbased ultra-fast VMAT planning practical for real clinical use.

  7. Power and Frequency Control as it Relates to Wind-Powered Generation

    E-Print Network [OSTI]

    Lacommare, Kristina S H

    2011-01-01

    5   2.2   Balancing Areas and Generating Plantvariations of load and generating plant output closely so as1. Balancing Areas and Generating Plant Types Simulations

  8. Load Monitoring CEC/LMTF Load Research Program

    SciTech Connect (OSTI)

    Huang, Zhenyu; Lesieutre, B.; Yang, Steve; Ellis, A.; Meklin, A.; Wong, B.; Gaikwad, A.; Brooks, D.; Hammerstrom, Donald J.; Phillips, John; Kosterev, Dmitry; Hoffman, M.; Ciniglio, O.; Hartwell, R.; Pourbeik, P.; Maitra, A.; Lu, Ning

    2007-11-30

    This white paper addresses the needs, options, current practices of load monitoring. Recommendations on load monitoring applications and future directions are also presented.

  9. 1256 IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 18, NO. 4, NOVEMBER 2003 Short-Term Hydrothermal Generation Scheduling

    E-Print Network [OSTI]

    Catholic University of Chile (Universidad Católica de Chile)

    , and economic load dispatch. Considering a scheduling horizon period of a week, hourly generation schedules

  10. The B61-based "Robust Nuclear Earth Penetrator:" Clever retrofit or headway towards fourth-generation nuclear weapons?

    E-Print Network [OSTI]

    Gsponer, A

    2005-01-01

    It is scientifically and technically possible to build an earth penetrating device that could bury a B61-7 warhead 30 meters into concrete, or 150 meters into earth, before detonating it. The device (based on knowledge and technology that is available since 50 years) would however by large and cumbersome. Better penetrator materials, components able to withstand larger stresses, higher impact velocities, and/or high-explosive driven penetration aids, can only marginally improve the device. It is conclude that the robust nuclear earth penetrator (RNEP) program may be as much motivated by the development of new technology directly applicable to next generation nuclear weapons, and by the political necessity to periodically reasses the role and utility of nuclear weapons, then by the perceived military need of a weapon able to destroy deeply buried targets.

  11. Gearbox Reliability Collaborative (GRC) Description and Loading

    SciTech Connect (OSTI)

    Oyague, F.

    2011-11-01

    This document describes simulated turbine load cases in accordance to the IEC 61400-1 Ed.3 standard, which is representative of the typical wind turbine design process. The information presented herein is intended to provide a broad understanding of the gearbox reliability collaborative 750kW drivetrain and turbine configuration. In addition, fatigue and ultimate strength drivetrain loads resulting from simulations are presented. This information provides the bases for the analytical work of the gearbox reliability collaborative effort.

  12. Remote Area Power Supply (RAPS) load and resource profiles.

    SciTech Connect (OSTI)

    Giles, Lauren (Energetics, Inc., Washington, DC); Skolnik, Edward G. (Energetics, Inc., Washington, DC); Marchionini, Brian (Energetics, Inc., Washington, DC); Fall, Ndeye K. (Energetics, Inc., Washington, DC)

    2007-07-01

    In 1997, an international team interested in the development of Remote Area Power Supply (RAPS) systems for rural electrification projects around the world was organized by the International Lead Zinc Research Organization (ILZRO) with the support of Sandia National Laboratories (SNL). The team focused on defining load and resource profiles for RAPS systems. They identified single family homes, small communities, and villages as candidates for RAPS applications, and defined several different size/power requirements for each. Based on renewable energy and resource data, the team devised a ''strawman'' series of load profiles. A RAPS system typically consists of a renewable and/or conventional generator, power conversion equipment, and a battery. The purpose of this report is to present data and information on insolation levels and load requirements for ''typical'' homes, small communities, and larger villages around the world in order to facilitate the development of robust design practices for RAPS systems, and especially for the storage battery component. These systems could have significant impact on areas of the world that would otherwise not be served by conventional electrical grids.

  13. Popping the CO{sub 2}RC: an alternative Load-Based CO{sub 2} Cap-and-Trade instrument for the electricity Sector

    SciTech Connect (OSTI)

    Michel, Steven; Nielsen, John

    2008-05-15

    The CO{sub 2}RC method proposed by the authors can effectively reduce CO{sub 2} emissions in electricity markets in a way that is easy to administer, avoids difficult allowance distribution issues, and eliminates leakage because it involves all generators. It provides strong and direct incentives for renewables and efficiency, and promises to work well in markets with incomplete participation. (author)

  14. Short-Term Load Forecasting This paper discusses the state of the art in short-term load fore-

    E-Print Network [OSTI]

    Gross, George

    spectrum of time intervals. In therange of seconds, when load variationsare small and random, the automatic by a number of generation control functions such as hydro scheduling, unit commitment, hydro-ther- mal present, functions such as fuel, hydro, and maintenance scheduling are performed to ensure that the load

  15. Automotive Power Generation and Control

    E-Print Network [OSTI]

    Caliskan, Vahe

    This paper describes some new developments in the application of power electronics to automotive power generation and control. A new load-matching technique is introduced that uses a simple switched-mode rectifier to achieve ...

  16. Electrical property measurements of thin film based Lithium Ion Battery electrodes "Nanostructured Lithium Ion Batteries (LIB) are one of the most promising class of next generation energy

    E-Print Network [OSTI]

    Milgram, Paul

    Electrical property measurements of thin film based Lithium Ion Battery electrodes "Nanostructured Lithium Ion Batteries (LIB) are one of the most promising class of next generation energy storage devices materials during the charging/discharging process. However, in previous graphene based LIB battery research

  17. Standardized Software for Wind Load Forecast Error Analyses and Predictions Based on Wavelet-ARIMA Models - Applications at Multiple Geographically Distributed Wind Farms

    SciTech Connect (OSTI)

    Hou, Zhangshuan; Makarov, Yuri V.; Samaan, Nader A.; Etingov, Pavel V.

    2013-03-19

    Given the multi-scale variability and uncertainty of wind generation and forecast errors, it is a natural choice to use time-frequency representation (TFR) as a view of the corresponding time series represented over both time and frequency. Here we use wavelet transform (WT) to expand the signal in terms of wavelet functions which are localized in both time and frequency. Each WT component is more stationary and has consistent auto-correlation pattern. We combined wavelet analyses with time series forecast approaches such as ARIMA, and tested the approach at three different wind farms located far away from each other. The prediction capability is satisfactory -- the day-ahead prediction of errors match the original error values very well, including the patterns. The observations are well located within the predictive intervals. Integrating our wavelet-ARIMA (‘stochastic’) model with the weather forecast model (‘deterministic’) will improve our ability significantly to predict wind power generation and reduce predictive uncertainty.

  18. Evolved strains of Scheffersomyces stipitis achieving high ethanol productivity on acid- and base-pretreated biomass hydrolyzate at high solids loading

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Slininger, Patricia J; Shea-Andersh, Maureen A; Thompson, Stephanie R; Dien, Bruce S; Kurtzman, Cletus P; Balan, Venkatesh; da Costa Sousa, Leonardo; Uppugundla, Nirmal; Dale, Bruce E; Cotta, Michael A

    2015-12-01

    Lignocellulosic biomass is an abundant, renewable feedstock useful for the production of fuel-grade ethanol via the processing steps of pretreatment, enzyme hydrolysis, and microbial fermentation. Traditional industrial yeasts do not ferment xylose and are not able to grow, survive, or ferment in concentrated hydrolyzates that contain enough sugar to support economical ethanol recovery since they are laden with toxic byproducts generated during pretreatment.

  19. Distributed Generation with Heat Recovery and Storage

    E-Print Network [OSTI]

    Siddiqui, Afzal S.; Marnay, Chris; Firestone, Ryan M.; Zhou, Nan

    2008-01-01

    Only Load Electricity Generation By Fuel in the U.S.electricity generation from most sources, except oil, is growing to meet the growing demand and that fossil fuels

  20. Low reflectance radio frequency load

    DOE Patents [OSTI]

    Ives, R. Lawrence; Mizuhara, Yosuke M

    2014-04-01

    A load for traveling microwave energy has an absorptive volume defined by cylindrical body enclosed by a first end cap and a second end cap. The first end cap has an aperture for the passage of an input waveguide with a rotating part that is coupled to a reflective mirror. The inner surfaces of the absorptive volume consist of a resistive material or are coated with a coating which absorbs a fraction of incident RF energy, and the remainder of the RF energy reflects. The angle of the reflector and end caps is selected such that reflected RF energy dissipates an increasing percentage of the remaining RF energy at each reflection, and the reflected RF energy which returns to the rotating mirror is directed to the back surface of the rotating reflector, and is not coupled to the input waveguide. Additionally, the reflector may have a surface which generates a more uniform power distribution function axially and laterally, to increase the power handling capability of the RF load. The input waveguide may be corrugated for HE11 mode input energy.

  1. Photovoltaic power converter system with a controller configured to actively compensate load harmonics

    DOE Patents [OSTI]

    de Rooij, Michael Andrew (Clifton Park, NY); Steigerwald, Robert Louis (Burnt Hills, NY); Delgado, Eladio Clemente (Burnt Hills, NY)

    2008-12-16

    Photovoltaic power converter system including a controller configured to reduce load harmonics is provided. The system comprises a photovoltaic array and an inverter electrically coupled to the array to generate an output current for energizing a load connected to the inverter and to a mains grid supply voltage. The system further comprises a controller including a first circuit coupled to receive a load current to measure a harmonic current in the load current. The controller includes a second circuit to generate a fundamental reference drawn by the load. The controller further includes a third circuit for combining the measured harmonic current and the fundamental reference to generate a command output signal for generating the output current for energizing the load connected to the inverter. The photovoltaic system may be configured to compensate harmonic currents that may be drawn by the load.

  2. Detailed Energy Data Collection for Miscellaneous and Electronic Loads in a Commercial Office Building

    E-Print Network [OSTI]

    California at Berkeley, University of

    Detailed Energy Data Collection for Miscellaneous and Electronic Loads in a Commercial Office to cost-effectively generate representative MELs energy data for future studies, this study addressed

  3. High-Bandwidth AFM-Based Rheology Reveals that Cartilage is Most Sensitive to High Loading Rates at Early Stages of Impairment

    E-Print Network [OSTI]

    Tavakoli Nia, Hadi

    Utilizing a newly developed atomic-force-microscopy-based wide-frequency rheology system, we measured the dynamic nanomechanical behavior of normal and glycosaminoglycan (GAG)-depleted cartilage, the latter representing ...

  4. Methods and apparatus for rotor load control in wind turbines

    DOE Patents [OSTI]

    Moroz, Emilian Mieczyslaw

    2006-08-22

    A wind turbine having a rotor, at least one rotor blade, and a plurality of generators, of which a first generator is configured to provide power to an electric grid and a second generator is configured to provide power to the wind turbine during times of grid loss. The wind turbine is configured to utilize power provided by the second generator to reduce loads on the wind turbine during times of grid loss.

  5. Load research manual. Volume 1. Load research procedures

    SciTech Connect (OSTI)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  6. Measuring alignment of loading fixture

    DOE Patents [OSTI]

    Scavone, Donald W. (Saratoga Springs, NY)

    1989-01-01

    An apparatus and method for measuring the alignment of a clevis and pin type loading fixture for compact tension specimens include a pair of substantially identical flat loading ligaments. Each loading ligament has two apertures for the reception of a respective pin of the loading fixture and a thickness less than one-half of a width of the clevis opening. The pair of loading ligaments are mounted in the clevis openings at respective sides thereof. The loading ligaments are then loaded by the pins of the loading fixture and the strain in each loading ligament is measured. By comparing the relative strain of each loading ligament, the alignment of the loading fixture is determined. Preferably, a suitable strain gage device is located at each longitudinal edge of a respective loading ligament equidistant from the two apertures in order to determine the strain thereat and hence the strain of each ligament. The loading ligaments are made substantially identical by jig grinding the loading ligaments as a matched set. Each loading ligament can also be individually calibrated prior to the measurement.

  7. Parametric study of broadband terahertz radiation generation based on interaction of two-color ultra-short laser pulses

    SciTech Connect (OSTI)

    Moradi, S.; Ganjovi, A.; Shojaei, F.; Saeed, M.

    2015-04-15

    In this work, using a two-dimensional kinetic model based on particle in cell-Monte Carlo collision simulation method, the influence of different parameters on the broadband intense Terahertz (THz) radiation generation via application of two-color laser fields, i.e., the fundamental and second harmonic modes, is studied. These two modes are focused into the molecular oxygen (O{sub 2}) with uniform density background gaseous media and the plasma channels are created. Thus, a broadband THz pulse that is around the plasma frequency is emitted from the formed plasma channel and co-propagates with the laser pulse. For different laser pulse shapes, the THz electric field and its spectrum are both calculated. The effects of laser pulse and medium parameters, i.e., positive and negative chirp pulse, number of laser cycles in the pulse, laser pulse shape, background gas pressure, and exerted DC electric field on THz spectrum are verified. Application of a negatively chirped femtosecond (40 fs) laser pulse results in four times enhancement of the THz pulse energy (2 times in THz electric field). The emission of THz radiation is mostly observed in the forward direction.

  8. 770 IEEE TRANSACTIONS ON SMART GRID, VOL. 3, NO. 2, JUNE 2012 Residential Load Control: Distributed Scheduling and

    E-Print Network [OSTI]

    Giannakis, Georgios

    been termed demand response or load response, among others; see, e.g., [2], [3]. Residential loads have770 IEEE TRANSACTIONS ON SMART GRID, VOL. 3, NO. 2, JUNE 2012 Residential Load Control: Distributed residential end-user has a base load, two types of adjustable loads, and pos- sibly a storage device

  9. Reliability Evaluation of Electric Power Generation Systems with Solar Power 

    E-Print Network [OSTI]

    Samadi, Saeed

    2013-11-08

    Conventional power generators are fueled by natural gas, steam, or water flow. These generators can respond to fluctuating load by varying the fuel input that is done by a valve control. Renewable power generators such as ...

  10. Electrical Load Modeling and Simulation

    SciTech Connect (OSTI)

    Chassin, David P.

    2013-01-01

    Electricity consumer demand response and load control are playing an increasingly important role in the development of a smart grid. Smart grid load management technologies such as Grid FriendlyTM controls and real-time pricing are making their way into the conventional model of grid planning and operations. However, the behavior of load both affects, and is affected by load control strategies that are designed to support electric grid planning and operations. This chapter discussed the natural behavior of electric loads, how it interacts with various load control and demand response strategies, what the consequences are for new grid operation concepts and the computing issues these new technologies raise.

  11. Generation of continuous and pulsed diagnostic imaging x-ray radiation using a carbon-nanotube-based field-emission cathode

    E-Print Network [OSTI]

    -nanotube-based field-emission cathode G. Z. Yue Department of Physics, University of North Carolina, Chapel Hill, North-ray radiation can be generated using a carbon nanotube CNT -based field-emission cathode. The device can readily emission current of 28 mA was obtained from a 0.2 cm2 area CNT cathode. The x-ray intensity is sufficient

  12. Buildings Stock Load Control 

    E-Print Network [OSTI]

    Joutey, H. A.; Vaezi-Nejad, H.; Clemoncon, B.; Rosenstein, F.

    2006-01-01

    , Shenzhen, China Building Commissioning for Energy Efficiency and Comfort, Vol.VI-9-4 Buildings Stock Load Control Ms H. Amrani Joutey Mr H. Vaezi-Nejad Mr B. Clemonçon Mr F.Rosenstein PHD student Research engineer Research... electricity consumption and curtail peak demand but in local form: building by building. Few developments are carried out for multi sites management. Multi sites management is essential in crisis and/or peak periods (large energy demand in particular during...

  13. Load responsive hydrodynamic bearing

    DOE Patents [OSTI]

    Kalsi, Manmohan S. (Houston, TX); Somogyi, Dezso (Sugar Land, TX); Dietle, Lannie L. (Stafford, TX)

    2002-01-01

    A load responsive hydrodynamic bearing is provided in the form of a thrust bearing or journal bearing for supporting, guiding and lubricating a relatively rotatable member to minimize wear thereof responsive to relative rotation under severe load. In the space between spaced relatively rotatable members and in the presence of a liquid or grease lubricant, one or more continuous ring shaped integral generally circular bearing bodies each define at least one dynamic surface and a plurality of support regions. Each of the support regions defines a static surface which is oriented in generally opposed relation with the dynamic surface for contact with one of the relatively rotatable members. A plurality of flexing regions are defined by the generally circular body of the bearing and are integral with and located between adjacent support regions. Each of the flexing regions has a first beam-like element being connected by an integral flexible hinge with one of the support regions and a second beam-like element having an integral flexible hinge connection with an adjacent support region. A least one local weakening geometry of the flexing region is located intermediate the first and second beam-like elements. In response to application of load from one of the relatively rotatable elements to the bearing, the beam-like elements and the local weakening geometry become flexed, causing the dynamic surface to deform and establish a hydrodynamic geometry for wedging lubricant into the dynamic interface.

  14. Shot loading trainer analysis

    SciTech Connect (OSTI)

    Peterson, T.K.

    1995-02-15

    This document presents the results from the analysis of the shot loading trainer (SLT). This device will be used to test the procedure for installing shot into the annulus of the Project W-320 shipping container. To ensure that the shot is installed uniformly around the container, vibrators will be used to settle the shot. The SLT was analyzed to ensure that it would not jeopardize worker safety during operation. The results from the static analysis of the SLT under deadweight and vibrator operating loads show that the stresses in the SLT are below code allowables. The results from the modal analysis show that the natural frequencies of the SLT are far below the operating frequencies of the vibrators, provided the SLT is mounted on pneumatic tires. The SLT was also analyzed for wind, seismic, deadweight, and moving/transporting loads. Analysis of the SLT is in accordance with SDC-4.1 for safety class 3 structures (DOE-RL 1993) and the American Institute of Steel Construction (AISC) Manual of Steel Construction (AISC 1989).

  15. Optimizing the performance of Ice-storage Systems in Electricity Load Management through a credit mechanism. An analytical work for Jiangsu, China

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Han, Yafeng; Shen, Bo; Hu, Huajin; Fan, Fei

    2015-01-12

    Ice-storage air-conditioning is a technique that uses ice for thermal energy storage. Replacing existing air conditioning systems with ice storage has the advantage of shifting the load from on-peak times to off-peak times that often have excess generation. However, increasing the use of ice-storage faces significant challenges in China. One major barrier is the inefficiency in the current electricity tariff structure. There is a lack of effective incentive mechanism that induces ice-storage systems from achieving optimal load-shifting results. This study presents an analysis that compares the potential impacts of ice-storage systems on load-shifting under a new credit-based incentive scheme andmore »the existing incentive arrangement in Jiangsu, China. The study indicates that by changing how ice-storage systems are incentivized in Jiangsu, load-shifting results can be improved.« less

  16. Optimizing the performance of Ice-storage Systems in Electricity Load Management through a credit mechanism. An analytical work for Jiangsu, China

    SciTech Connect (OSTI)

    Han, Yafeng; Shen, Bo; Hu, Huajin; Fan, Fei

    2015-01-12

    Ice-storage air-conditioning is a technique that uses ice for thermal energy storage. Replacing existing air conditioning systems with ice storage has the advantage of shifting the load from on-peak times to off-peak times that often have excess generation. However, increasing the use of ice-storage faces significant challenges in China. One major barrier is the inefficiency in the current electricity tariff structure. There is a lack of effective incentive mechanism that induces ice-storage systems from achieving optimal load-shifting results. This study presents an analysis that compares the potential impacts of ice-storage systems on load-shifting under a new credit-based incentive scheme and the existing incentive arrangement in Jiangsu, China. The study indicates that by changing how ice-storage systems are incentivized in Jiangsu, load-shifting results can be improved.

  17. Load Management: Opportunity or Calamity? 

    E-Print Network [OSTI]

    Males, R.; Hassig, N.

    1981-01-01

    larger now than prior to 1973. Utilities are examining two options which can be termed load management. One option is to control discretionary loads during peak periods. Cycling of residential water heaters or shutting off industrial electric furnaces...

  18. An unconventional method for load balancing

    SciTech Connect (OSTI)

    Deng, Y.; McCoy, R.A.; Marr, R.B.

    1995-12-01

    A new method of load balancing is introduced based on the idea of dynamically relocating virtual processes corresponding to computations on an abstract system with a larger number of processors. The algorithm introduced preserves the locality of nearest neighbor interactions and has been tested on simulated data and a molecular dynamics code.

  19. An unconventional method for load balancing

    SciTech Connect (OSTI)

    Deng, Y.; McCoy, R.A.; Marr, R.B.; Peierls, R.F.

    1995-08-01

    A new method of load balancing is introduced based on the idea of dynamically relocating virtual processes corresponding to computations on an abstract system with a large number of processors. The algorithm introduced preserves the locality of nearest neighbor interactions and has been tested on simulated data and a molecular dynamics code.

  20. Determining site-specific drum loading criteria for storing combustible {sup 238}Pu waste

    SciTech Connect (OSTI)

    Marshall, R.S.; Callis, E.L.; Cappis, J.H.; Espinoza, J.M.; Foltyn, E.M.; Reich, B.T.; Smith, M.C.

    1994-02-01

    Waste containing hydrogenous-combustible material contaminated with {sup 238}Pu can generate hydrogen gas at appreciable rates through alpha radiolysis. To ensure safe transportation of WIPP drums, the limit for {sup 238}Pu-combustible waste published in the WIPP TRUPACT-11 CONTENT (TRUCON) CODES is 21 milliwafts per 55 gallon drum. This corresponds to about 45 milligrams of {sup 238}PuO{sub 2} used for satellite heat source-electrical generators. The Los Alamos waste storage site adopted a {sup 238}Pu waste storage criteria based on these TRCUCON codes. However, reviews of the content in drums of combustible waste generated during heat source assembly at Los Alamos showed the amount of {sup 238}Pu is typically much greater than 45 milligrams. It is not feasible to appreciably reduce Los Alamos {sup 238}Pu waste drum loadings without significantly increasing waste volumes or introducing unsafe practices. To address this concern, a series of studies were implemented to evaluate the applicability of the TRUCON limits for storage of this specific waste. Addressed in these evaluations were determination of the hydrogen generation rate, hydrogen diffusion rates through confinement layers and vent filters, and packaging requirements specific to Los Alamos generated {sup 238}Pu contaminated combustible waste. These studies also showed that the multiple-layer packaging practices in use at Los Alamos could be relaxed without significantly increasing the risk of contamination. Based on a model developed to predict H{sub 2} concentrations in packages and drum headspace, the site specific effective hydrogen generation rate, and hydrogen-diffusion values, and revising the waste packaging practices, we were able to raise the safe loading limit for {sup 238}Pu waste drums for on site storage to the gram levels typical of currently generated {sup 238}Pu waste.

  1. Electrical transient stability and underfrequency load shedding analysis for a large pump station

    SciTech Connect (OSTI)

    Shilling, S.R. [Saudi Aramco, Dhahran (Saudi Arabia)

    1995-12-31

    Electrical transients from faults, loss of generation, and load swings can disrupt pump station operations. Isolated stations with no utility tie and those with weak utility ties are especially at risk. Relative to this problem, the following four main issues are addressed: (1) Analyze the methods that use high-speed underfrequency load shedding to maintain system stability and preserve station operations. (2) Analyze combustion gas turbine generator and diesel generator transient responses, as they pertain to the Electrical Engineer. (3) Discuss system component modeling and the use of low voltage circuit switching devices to shed loads. (4) Compare two computer analysis program outputs for underfrequency load shedding responses.

  2. Electrical transient stability and underfrequency load shedding analysis for a large pump station

    SciTech Connect (OSTI)

    Shilling, S.R. [Saudi Aramco, Dhahran (Saudi Arabia)] [Saudi Aramco, Dhahran (Saudi Arabia)

    1997-01-01

    Electrical transients from faults, loss of generation, and load swings can disrupt pump station operations. Isolated stations with no utility tie, and those with weak utility ties, are especially at risk. Relative to this problem, the following four main issues are addressed: (1) analyze the methods that use high-speed underfrequency load shedding to maintain system stability and preserve station operations; (2) analyze combustion gas turbine generator and diesel generator transient responses, as they pertain to the electrical engineer; (3) discuss system component modeling and the use of low voltage circuit switching devices to shed loads; (4) compare two computer analysis program outputs for underfrequency load shedding responses.

  3. Cluster generator

    DOE Patents [OSTI]

    Donchev, Todor I. (Urbana, IL); Petrov, Ivan G. (Champaign, IL)

    2011-05-31

    Described herein is an apparatus and a method for producing atom clusters based on a gas discharge within a hollow cathode. The hollow cathode includes one or more walls. The one or more walls define a sputtering chamber within the hollow cathode and include a material to be sputtered. A hollow anode is positioned at an end of the sputtering chamber, and atom clusters are formed when a gas discharge is generated between the hollow anode and the hollow cathode.

  4. Transportation Electrification Load Development For a Renewable Future Analysis

    SciTech Connect (OSTI)

    Markel, Tony; Mai, Trieu; Kintner-Meyer, Michael CW

    2010-09-30

    Electrification of the transportation sector offers the opportunity to significantly reduce petroleum consumption. The transportation sector accounts for 70% of US petroleum consumption. The transition to electricity as a transportation fuel will create a new load for electricity generation. In support of a recent US Department of Energy funded activity that analyzed a future generation scenario with high renewable energy technology contributions, a set of regional hourly load profiles for electrified vehicles were developed for the 2010 to 2050 timeframe. These load profiles with their underlying assumptions will be presented in this paper. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determine the number of plug-in electric vehicles (PEVs) in each analysis region. Two market saturation scenarios of 30% of sales and 50% of sales of PEVs consuming on average {approx}6 kWh per day were considered. Results were generated for 3109 counties and were consolidated to 134 Power Control Areas (PCA) for the use NREL's's regional generation planning analysis tool ReEDS. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging toward utility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across 4 daily time slices under optimal control from the utility perspective. No other literature has addressed the potential flexibility in energy delivery to electric vehicles in connection with a regional power generation study. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetration scenarios. EVS25 Copyright.

  5. Aalborg Universitet Comparison of Steady-State SVC Models in Load Flow Calculations

    E-Print Network [OSTI]

    Bak-Jensen, Birgitte

    that the electrical distance between the generators and the load centers is controlled. The shunt- connected FACTS-state models of static var compensator (SVC), i.e. the generator-fixed susceptance model, the total susceptance bus, equivalent SVC susceptance at the fundamental frequency and the load flow convergence rate when

  6. Testing Controls to Mitigate Fatigue Loads in the Controls Advanced Research Turbine

    SciTech Connect (OSTI)

    Wright, A. D.; Fingersh, L. J.; Stol, K. A.

    2009-01-01

    Wind turbines are complex, nonlinear, dynamic systems forced by aerodynamic, gravitational, centrifugal, and gyroscopic loads. The aerodynamics of wind turbines is nonlinear, unsteady, and complex. Turbine rotors are subjected to a complicated three-dimensional (3D) turbulent wind inflow field with imbedded coherent vortices that drive fatigue loads and reduce lifetime. Design of control algorithms for wind turbines must account for multiple control objectives. Future large multi-megawatt turbines must be designed with lighter weight structures, using active controls to mitigate fatigue loads, maximize energy capture, and add active damping to maintain stability for these dynamically active structures operating in a complex environment. Researchers at the National Renewable Energy Laboratory are designing, implementing, and testing advanced controls to maximize energy extraction and reduce structural dynamic loads. These control designs are based on a linear model of the turbine that is generated by specialized modeling software. This paper describes testing of a control algorithm to mitigate blade, tower, and drivetrain loads using advanced state-space control methods. The controller uses independent blade pitch to regulate the turbine's speed in Region 3, mitigate the effects of shear across the rotor disk, and add active damping to the tower's first fore-aft bending mode. Additionally, a separate generator torque control loop is designed to add active damping to the tower's first side-side mode and the first drivetraintorsion mode. This paper discusses preliminary implementation and field tests of this controller in the Controls Advanced Research Turbine at the National Renewable Energy Laboratory. Also included are preliminary comparisons of the performance of this controller to results from a typical baseline Proportional-Integral-Derivative controller designed with just Region 3 speed regulation as the goal.

  7. Variable loading roller

    DOE Patents [OSTI]

    Williams, Daniel M. (Oliver Springs, TN)

    1989-01-01

    An automatic loading roller for transmitting torque in traction drive devices in manipulator arm joints includes a two-part camming device having a first cam portion rotatable in place on a shaft by an input torque and a second cam portion coaxially rotatable and translatable having a rotating drive surface thereon for engaging the driven surface of an output roller with a resultant force proportional to the torque transmitted. Complementary helical grooves on the respective cam portions interconnected through ball bearings interacting with those grooves effect the rotation and translation of the second cam portion in response to rotation of the first.

  8. Variable loading roller

    DOE Patents [OSTI]

    Williams, D.M.

    1988-01-21

    An automatic loading roller for transmitting torque in traction drive devices in manipulator arm joints includes a two-part camming device having a first cam portion rotatable in place on a shaft by an input torque and a second cam portion coaxially rotatable and translatable having a rotating drive surface thereon for engaging the driven surface of an output roller with a resultant force proportional to the torque transmitted. Complementary helical grooves in the respective cam portions interconnected through ball bearings interacting with those grooves effect the rotation and translation of the second cam portion in response to rotation of the first. 14 figs.

  9. Metal loading and reactivity of Zeolite Y 

    E-Print Network [OSTI]

    Sa?enz, Marc Gerard

    1988-01-01

    V) are transi- tion metal oxides or sulfides on an alumina support. These catalysts were not specifically developed for hydrodenitrogenaiion but were adopted from hydrocracking or hydrodesul- furization (HDS) processes. HDN is more difficult than HDS; thus... No. ;&778365, "Hydrocracking and Hydrodenitrogenation of Shale Oil" (7). The patent disclosed a class of catalysi. s based on large pore zeolites loaded v;ith transition metals. The zeolite based catalysts were preferred over the traditional alumina...

  10. Distributional Analysis for Model Predictive Deferrable Load Control

    E-Print Network [OSTI]

    Low, Steven H.

    for demand response. There are two major categories of demand response, direct load control (DLC) and price-based demand response. See [1] for a discussion of the contrasts between these approaches. In this paper we focus on direct load control with the goal of using demand response to reduce variations

  11. PhotoVoltaic distributed generation for Lanai power grid real-time simulation and control integration scenario.

    SciTech Connect (OSTI)

    Robinett, Rush D., III; Kukolich, Keith; Wilson, David Gerald; Schenkman, Benjamin L.

    2010-06-01

    This paper discusses the modeling, analysis, and testing in a real-time simulation environment of the Lanai power grid system for the integration and control of PhotoVoltaic (PV) distributed generation. The Lanai Island in Hawaii is part of the Hawaii Clean Energy Initiative (HCEI) to transition to 30% renewable green energy penetration by 2030. In Lanai the primary loads come from two Castle and Cook Resorts, in addition to residential needs. The total peak load profile is 12470 V, 5.5 MW. Currently there are several diesel generators that meet these loading requirements. As part of the HCEI, Lanai has initially installed 1.2 MW of PV generation. The goal of this study has been to evaluate the impact of the PV with respect to the conventional carbon-based diesel generation in real time simulation. For intermittent PV distributed generation, the overall stability and transient responses are investigated. A simple Lanai 'like' model has been developed in the Matlab/Simulink environment (see Fig. 1) and to accommodate real-time simulation of the hybrid power grid system the Opal-RT Technologies RT-Lab environment is used. The diesel generators have been modelled using the SimPowerSystems toolbox swing equations and a custom Simulink module has been developed for the High level PV generation. All of the loads have been characterized primarily as distribution lines with series resistive load banks with one VAR load bank. Three-phase faults are implemented for each bus. Both conventional and advanced control architectures will be used to evaluate the integration of the PV onto the current power grid system. The baseline numerical results include the stable performance of the power grid during varying cloud cover (PV generation ramping up/down) scenarios. The importance of assessing the real-time scenario is included.

  12. Optimizing Process Loads in Industrial Cogeneration Energy Systems 

    E-Print Network [OSTI]

    Ahner, D. J.; Babson, P. E.

    1995-01-01

    W OPTIMIZING PROCESS LOADS IN INDUSTRIAL COGENERAnON ENERGY SYSTEMS DJ. Ahner Manager, Generation Technology Power Tecbnologies, Inc. Schenectady, New York ABSTRACT Optimum dispatcb of energy supply systems can result in large savings... and industrial cogeneration are extended to solving this trigeneration problem where the optimum dispatch of the final load devices (i.e. compressors, fans, pumps, etc.) are an integral part of the total energy system optimization. An example industrial...

  13. Thermal tracking cogeneration -- A new or old idea? Cogeneration for multi-thermal loads

    SciTech Connect (OSTI)

    Geers, J.R.

    1998-04-01

    The idea of designing a cogeneration project that produces electricity based on the existing heating load is common to many cogeneration projects, but may be limiting the ultimate potential to the end user. Cogeneration which is developed as a power generator producing a small amount of steam for a host load is also common. However, the idea of designing a cogeneration facility to track multiple utility loads is not as common. Where the concept has been used, the projects have been very successful. This article has been written as a primer for professionals looking for ideas when performing analysis of a potential cogeneration project, and as a thought-provoker for end users. The authors will look at each of the possible loads, outline various technical considerations and factors, look at the factors impacting the economics, and lay out an approach that would provide assistance to those trying to analyze a cogeneration project without specialized engineering assistance. Regulatory, legal and financing issues are covered in other sources.

  14. Changes in the Economic Value of Variable Generation at High Penetration Levels: A Pilot Case Study of California

    E-Print Network [OSTI]

    Mills, Andrew

    2013-01-01

    Variable generation Value of lost load Introduction Longestimates of the value of lost load (VOLL) (Stoft, 2002). 16costs equal to the value of lost load (VOLL) and reliability

  15. Changes in the Economic Value of Variable Generation at High Penetration Levels: A Pilot Case Study of California

    E-Print Network [OSTI]

    Mills, Andrew D.

    2014-01-01

    Variable generation Value of lost load Introduction TheIn particular, the value of lost load is assumed to be $$200/kW-yr and the value of lost load is assumed to be $

  16. JOURNAL OF LIGHTWAVE TECHNOLOGY, VOL. 24, NO. 11, NOVEMBER 2006 4263 PLC-Based Pulse-Train Generators

    E-Print Network [OSTI]

    Purdue University

    JOURNAL OF LIGHTWAVE TECHNOLOGY, VOL. 24, NO. 11, NOVEMBER 2006 4263 PLC-Based Pulse to the fab- rication of optical devices [1]­[3]. PLC-based fabrication is frequently employed in a wide range the range of applications utilizing PLC- based devices is enormous, the focus of this paper

  17. Diophantine Generation,

    E-Print Network [OSTI]

    Shlapentokh, Alexandra

    Diophantine Generation, Horizontal and Vertical Problems, and the Weak Vertical Method Alexandra Shlapentokh Diophantine Sets, Definitions and Generation Diophantine Sets Diophantine Generation Properties of Diophantine Generation Diophantine Family of Z Diophantine Family of a Polynomial Ring Going Down Horizontal

  18. Near-IR supercontinuum generation based on a telecom single-mode fibre in an all-fibre format, and its power combining

    SciTech Connect (OSTI)

    Rumao Tao; Xiaolin Wang; Xiao, H; Zhou, P; Jing Hou [College of Optoelectronics Science and Engineering, National University of Defense Technology, Changsha, Hunan, 410073 (China)

    2014-04-28

    Near-IR supercontinuum (SC) is generated based on a standard telecommunication single-mode (SM) fibre in an all-fibre format. The observed spectrum covers the spectral range from 1050 nm to 1700 nm. High-efficiency combining of the SC power is demonstrated for the first time, and the spectral SC properties are shown to be maintained after power combining. The results may find applications in sensing, spectroscopy and medicine. (control of laser radiation parameters)

  19. Unit Commitment Considering Generation Flexibility and Environmental Constraints

    SciTech Connect (OSTI)

    Lu, Shuai; Makarov, Yuri V.; Zhu, Yunhua; Lu, Ning; Prakash Kumar, Nirupama; Chakrabarti, Bhujanga B.

    2010-07-31

    This paper proposes a new framework for power system unit commitment process, which incorporates the generation flexibility requirements and environmental constraints into the existing unit commitment algorithm. The generation flexibility requirements are to address the uncertainties with large amount of intermittent resources as well as with load and traditional generators, which causes real-time balancing requirements to be variable and less predictable. The proposed flexibility requirements include capacity, ramp and ramp duration for both upward and downward balancing reserves. The environmental constraints include emission allowance for fossil fuel-based generators and ecological regulations for hydro power plants. Calculation of emission rates is formulated. Unit commitment under this new framework will be critical to the economic and reliable operation of the power grid and the minimization of its negative environmental impacts, especially when high penetration levels of intermittent resources are being approached, as required by the renewable portfolio standards in many states.

  20. Electrical and Production Load Factors 

    E-Print Network [OSTI]

    Sen, T.; Heffington, W. M.

    2009-01-01

    factors and operating hours of small and medium-sized industrial plants are analyzed to classify shift-work patterns and develop energy conservation diagnostic tools. This paper discusses two types of electric load factors for each shift... The purpose of this paper is to analyze operating hours of small and medium-sized manufacturing plants in the United States and develop ranges of load factors for use as diagnostic tools for effective energy management. Load factor is defined...

  1. Third-generation cylindrical dendrimers based on L-aspargic acid in solutions: hydrodynamic and electrooptical properties

    E-Print Network [OSTI]

    Ilya Martchenko; Nikolai Tsvetkov

    2008-09-23

    Samples of third-generation cylindrical dendrimers with molar masses ranging in the interval 20000...60000 have been studied by the methods of equilibrium and non-equilibrium electrical birefringence, molecular hydrodynamics and optics. It was found that the absolute values of Kerr and flow birefringence constants exceed the values obtained for analogous dendrimers of lower generations. The mechanism of reorientation has proven to be strongly dependent on the physical and chemical properties of the solvent. In chloroform solutions, the studied dendrimers align to the microwave-frequency electric fields according to large-scale mechanism. In dichloroacetic acid solutions, the observed reorientation mechanism is low-scale, which is explained by degradation of intermolecular hydrogen bonds. Terminal dendritic substituents of the macromolecules have experimentally proven to be oriented mainly along the primary polymer chain.

  2. Hydrogen Gas Generation Model for Fuel-Based Remote-Handled Transuranic Waste Stored at the INEEL

    SciTech Connect (OSTI)

    Khericha, S.; Bhatt, R.; Liekhus, K.

    2003-01-14

    The Idaho National Environmental and Engineering Laboratory (INEEL) initiated efforts to calculate the hydrogen gas generation in remote-handled transuranic (RH-TRU) containers in order to evaluate continued storage of unvented RH-TRU containers in vaults and to identify any potential problems during retrieval and aboveground storage. A computer code is developed to calculate the hydrogen concentration in the stored RH-TRU waste drums for known configuration, waste matrix, and radionuclide inventories as a function of time.

  3. Refinements and Tests of an Advanced Controller to Mitigate Fatigue Loads in the Controls Advanced Research Turbine: Preprint

    SciTech Connect (OSTI)

    Wright, A.; Fleming, P.

    2010-12-01

    Wind turbines are complex, nonlinear, dynamic systems forced by aerodynamic, gravitational, centrifugal, and gyroscopic loads. The aerodynamics of wind turbines are nonlinear, unsteady, and complex. Turbine rotors are subjected to a complicated 3-D turbulent wind inflow field, with imbedded coherent vortices that drive fatigue loads and reduce lifetime. Design of control algorithms for wind turbines must account for multiple control objectives. Future large multi-megawatt turbines must be designed with lighter weight structures, using active controls to mitigate fatigue loads, while maximizing energy capture. Active damping should be added to these dynamic structures to maintain stability for operation in a complex environment. At the National Renewable Energy Laboratory (NREL), we have designed, implemented, and tested advanced controls to maximize energy extraction and reduce structural dynamic loads. These control designs are based on linear models of the turbine that are generated by specialized modeling software. In this paper, we present field test results of an advanced control algorithm to mitigate blade, tower, and drivetrain loads in Region 3.

  4. High-Power Rf Load

    DOE Patents [OSTI]

    Tantawi, Sami G. (San Mateo, CA); Vlieks, Arnold E. (Livermore, CA)

    1998-09-01

    A compact high-power RF load comprises a series of very low Q resonators, or chokes [16], in a circular waveguide [10]. The sequence of chokes absorb the RF power gradually in a short distance while keeping the bandwidth relatively wide. A polarizer [12] at the input end of the load is provided to convert incoming TE.sub.10 mode signals to circularly polarized TE.sub.11 mode signals. Because the load operates in the circularly polarized mode, the energy is uniformly and efficiently absorbed and the load is more compact than a rectangular load. Using these techniques, a load having a bandwidth of 500 MHz can be produced with an average power dissipation level of 1.5 kW at X-band, and a peak power dissipation of 100 MW. The load can be made from common lossy materials, such as stainless steel, and is less than 15 cm in length. These techniques can also produce loads for use as an alternative to ordinary waveguide loads in small and medium RF accelerators, in radar systems, and in other microwave applications. The design is easily scalable to other RF frequencies and adaptable to the use of other lossy materials.

  5. Review of current Southern California edison load management programs and proposal for a new market-driven, mass-market, demand-response program

    E-Print Network [OSTI]

    Weller, G.H.

    2002-01-01

    for emergency load management. e. Estimated Program Cost TheCommercial & Industrial (C&I) Load Management Programs A.on the Existing SCE Load Management System / Technology Base

  6. Electromagnetic fields in nonuniform disk-loaded waveguides

    E-Print Network [OSTI]

    Ayzatsky, M I

    2015-01-01

    On the base of general approach we obtain some results that can be useful in the process of tuning of nonunifrom disc-loaded waveguides. Our consideration has shown that simple values that characterize the detuning of the cells can be introduced only for the disc-loaded waveguide with parameters that change very slow. In general case it is needed to conduct full numerical simulation of specific disc-loaded waveguide and obtain all necessary coupling coefficients. After that one can start the tuning process on the base of bead-pull field distribution measurements.

  7. Reliability of islanded microgrids with stochastic generation and prioritized load

    E-Print Network [OSTI]

    Marden, Mirjana Milosevic

    The potential to improve distribution system reliability is a primary motivation behind the development and deployment of microgrids. Previous studies have illustrated substantial reliability benefits of dispatchable ...

  8. Study on a regeneration process of LiCl-KCl eutectic based waste salt generated from the pyrochemical process

    SciTech Connect (OSTI)

    Eun, H.C.; Cho, Y.Z.; Choi, J.H.; Kim, J.H.; Lee, T.K.; Park, H.S.; Kim, I.T.; Park, G.I.

    2013-07-01

    A regeneration process of LiCl-KCl eutectic waste salt generated from the pyrochemical process of spent nuclear fuel has been studied. This regeneration process is composed of a chemical conversion process and a vacuum distillation process. Through the regeneration process, a high efficiency of renewable salt recovery can be obtained from the waste salt and rare earth nuclides in the waste salt can be separated as oxide or phosphate forms. Thus, the regeneration process can contribute greatly to a reduction of the waste volume and a creation of durable final waste forms. (authors)

  9. Improved Average-Voice-based Speech Synthesis Using Gender-Mixed Modeling and a Parameter Generation Algorithm Considering GV 

    E-Print Network [OSTI]

    Yamagishi, Junichi; Kobayashi, Takao; Renals, Steve; King, Simon; Zen, Heiga; Toda, Tomoki; Tokuda, Keiichi

    For constructing a speech synthesis system which can achieve diverse voices, we have been developing a speaker independent approach of HMM-based speech synthesis in which statistical average voice models are adapted to ...

  10. Loading Relativistic Maxwell Distributions in Particle Simulations

    E-Print Network [OSTI]

    Zenitani, Seiji

    2015-01-01

    Numerical algorithms to load relativistic Maxwell distributions in particle-in-cell (PIC) and Monte-Carlo simulations are presented. For stationary relativistic Maxwellian, the inverse transform method and the Sobol algorithm are reviewed. To boost particles to obtain relativistic shifted-Maxwellian, two rejection methods are proposed in a physically transparent manner. Their acceptance efficiencies are ${\\approx}50\\%$ for generic cases and $100\\%$ for symmetric distributions. They can be combined with arbitrary base algorithms.

  11. Transportation Electrification Load Development For A Renewable Future Analysis: Preprint

    SciTech Connect (OSTI)

    Markel, T.; Mai, T.; Kintner-Meyer, M.

    2010-12-01

    The transition to electricity as a transportation fuel will create a new load for electricity generation. A set of regional hourly load profiles for electrified vehicles was developed for the 2010 to 2050 timeframe. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determine the number of plug-in electric vehicles (PEVs) in each analysis region. Market saturation scenarios of 30% and 50% of sales of PEVs consuming on average approx. 6 kWh per day were considered. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging toward utility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across four daily time slices under optimal control from the utility?s perspective. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetration scenarios.

  12. Right-Sizing Laboratory Equipment Loads

    SciTech Connect (OSTI)

    Frenze, David; Greenberg, Steve; Mathew, Paul; Sartor, Dale; Starr, William

    2005-11-29

    Laboratory equipment such as autoclaves, glass washers, refrigerators, and computers account for a significant portion of the energy use in laboratories. However, because of the general lack of measured equipment load data for laboratories, designers often use estimates based on 'nameplate' rated data, or design assumptions from prior projects. Consequently, peak equipment loads are frequently overestimated. This results in oversized HVAC systems, increased initial construction costs, and increased energy use due to inefficiencies at low part-load operation. This best-practice guide first presents the problem of over-sizing in typical practice, and then describes how best-practice strategies obtain better estimates of equipment loads and right-size HVAC systems, saving initial construction costs as well as life-cycle energy costs. This guide is one in a series created by the Laboratories for the 21st Century ('Labs21') program, a joint program of the U.S. Environmental Protection Agency and U.S. Department of Energy. Geared towards architects, engineers, and facilities managers, these guides provide information about technologies and practices to use in designing, constructing, and operating safe, sustainable, high-performance laboratories.

  13. Load Management - A Better Way 

    E-Print Network [OSTI]

    Easley, J. F.

    1982-01-01

    of load management techniques which has enabled the company to shift well over 100,000 kilowatts of customer load from the on-peak period to the off-peak period in the last four to five years. This is helping delay the need for new plants and allows...

  14. COMBINE7.1 - A Portable ENDF/B-VII.0 Based Neutron Spectrum and Cross-Section Generation Program

    SciTech Connect (OSTI)

    Woo Y. Yoon; David W. Nigg

    2011-09-01

    COMBINE7.1 is a FORTRAN 90 computer code that generates multigroup neutron constants for use in the deterministic diffusion and transport theory neutronics analysis. The cross-section database used by COMBINE7.1 is derived from the Evaluated Nuclear Data Files (ENDF/B-VII.0). The neutron energy range covered is from 20 MeV to 1.0E-5 eV. The Los Alamos National Laboratory NJOY code is used as the processing code to generate a 167 fine-group cross-section library in MATXS format for Bondarenko self-shielding treatment. Resolved resonance parameters are extracted from ENDF/B-VII.0 File 2 for a separate library to be used in an alternate Nordheim self-shielding treatment in the resolved resonance energy range. The equations solved for energy dependent neutron spectrum in the 167 fine-group structure are the B3 or B1 zero-dimensional approximations to the transport equation. The fine group cross sections needed for the spectrum calculation are first prepared by Bondarenko self-shielding interpolation in terms of background cross section and temperature. The geometric lump effect, when present, is accounted for by augmenting the background cross section. Nordheim self-shielded fine group cross sections for a material having resolved resonance parameters overwrite correspondingly the existing self-shielded fine group cross sections when this option is used. COMBINE7.1 coalesces fine group cross sections into broad group macroscopic and microscopic constants. The coalescing is performed by utilizing fine-group fluxes and/or currents obtained by spectrum calculation as the weighting functions. The multigroup constants may be output in any of several standard formats including INL format, ANISN 14** free format, CCCC ISOTXS format, and AMPX working library format. ANISN-PC, a one-dimensional (1-D) discrete-ordinate transport code, is incorporated into COMBINE7.1. As an option, the 167 fine-group constants generated by zero-dimensional COMBINE portion in the program can be used to calculate regionwise spectra in the 1-D ANISN portion, all internally to reflect the 1-D transport correction. The regionwise spectra are then used to generate mutigroup regionwise neutron constants. The 1-D neutron transport can be performed up to three stages, e.g., from a TRISO fuel to PEBBLE to 1-D full core wedge. In addition, COMBINE7.1 has now the capability of adjoint flux calculation through the 1-D ANISN transport. Photon transport capability is also added. For this, a photon production and photo-atomic cross section library, MATNG.LIB, was generated in MATXS format through NJOY code. The photon production cross section matrix is of 167 neutron - 18 photon groups. Photo-atomic cross sections, including heating, are in 18 energy groups.

  15. A new generation of load sharing algorithms: the semi-adaptive load sharing algorithm 

    E-Print Network [OSTI]

    Morsy, Hazem Kamal

    1997-01-01

    Distributed systems have become a popular computing environment. Due to their high potentials in improving performance and resource sharing, the evolution and maturing of technologies such as networks and computer hardware, have led to more...

  16. COMBINE7.1 - A Portable ENDF/B-VII.0 Based Neutron Spectrum and Cross-Section Generation Program

    SciTech Connect (OSTI)

    Woo Y. Yoon; David W. Nigg

    2009-08-01

    COMBINE7.1 is a FORTRAN 90 computer code that generates multigroup neutron constants for use in the deterministic diffusion and transport theory neutronics analysis. The cross-section database used by COMBINE7.1 is derived from the Evaluated Nuclear Data Files (ENDF/B-VII.0). The neutron energy range covered is from 20 MeV to 1.0E-5 eV. The Los Alamos National Laboratory NJOY code is used as the processing code to generate a 167 fine-group cross-section library in MATXS format for Bondarenko self-shielding treatment. Resolved resonance parameters are extracted from ENDF/B-VII.0 File 2 for a separate library to be used in an alternate Nordheim self-shielding treatment in the resolved resonance energy range. The equations solved for energy dependent neutron spectrum in the 167 fine-group structure are the B-3 or B-1 approximations to the transport equation. The fine group cross sections needed for the spectrum calculation are first prepared by Bondarenko self-shielding interpolation in terms of background cross section and temperature. The geometric lump effect, when present, is accounted for by augmenting the background cross section. Nordheim self-shielded fine group cross sections for a material having resolved resonance parameters overwrite correspondingly the existing self-shielded fine group cross sections when this option is used. The fine group cross sections in the thermal energy range are replaced by those self-shielded with the Amouyal/Benoist/Horowitz method in the three region geometry when this option is requested. COMBINE7.1 coalesces fine group cross sections into broad group macroscopic and microscopic constants. The coalescing is performed by utilizing fine-group fluxes and/or currents obtained by spectrum calculation as the weighting functions. The multigroup constant may be output in any of several standard formats including ANISN 14** free format, CCCC ISOTXS format, and AMPX working library format. ANISN-PC, a one-dimensional, discrete-ordinate transport code, is incoprated into COMBINE7.1. As an option, the 167 fine-group constants generated by COMBINE portion in the program can be used to cacluate regionwise spectra in the ANISN portion, all internally to reflect the one-dimensional transport correction. Results for the criticality validation calculations are included as a part of verification and validation.

  17. COMBINE7.0 - A Portable ENDF/B-VII.0 Based Neutron Spectrum and Cross-Section Generation Program

    SciTech Connect (OSTI)

    Woo Y. Yoon; David W. Nigg

    2008-09-01

    COMBINE7.0 is a FORTRAN 90 computer code that generates multigroup neutron constants for use in the deterministic diffusion and transport theory neutronics analysis. The cross-section database used by COMBINE7.0 is derived from the Evaluated Nuclear Data Files (ENDF/B-VII.0). The neutron energy range covered is from 20 MeV to 1.0E-5 eV. The Los Alamos National Laboratory NJOY code is used as the processing code to generate a 167 finegroup cross-section library in MATXS format for Bondarenko self-shielding treatment. Resolved resonance parameters are extracted from ENDF/B-VII.0 File 2 for a separate library to be used in an alternate Nordheim self-shielding treatment in the resolved resonance energy range. The equations solved for energy dependent neutron spectrum in the 167 fine-group structure are the B-3 or B-1 approximations to the transport equation. The fine group cross sections needed for the spectrum calculation are first prepared by Bondarenko selfshielding interpolation in terms of background cross section and temperature. The geometric lump effect, when present, is accounted for by augmenting the background cross section. Nordheim self-shielded fine group cross sections for a material having resolved resonance parameters overwrite correspondingly the existing self-shielded fine group cross sections when this option is used. The fine group cross sections in the thermal energy range are replaced by those selfshielded with the Amouyal/Benoist/Horowitz method in the three region geometry when this option is requested. COMBINE7.0 coalesces fine group cross sections into broad group macroscopic and microscopic constants. The coalescing is performed by utilizing fine-group fluxes and/or currents obtained by spectrum calculation as the weighting functions. The multigroup constant may be output in any of several standard formats including ANISN 14** free format, CCCC ISOTXS format, and AMPX working library format. ANISN-PC, a onedimensional, discrete-ordinate transport code, is incoprated into COMBINE7.0. As an option, the 167 fine-group constants generated by COMBINE portion in the program can be used to cacluate regionwise spectra in the ANISN portion, all internally to reflect the one-dimensional transport correction. Results for the criticality validation calculations are included as a part of verification and validation.

  18. GENERAL TECHNICAL REPORT PSW-GTR-245 Fuel Load Modeling From Mensuration

    E-Print Network [OSTI]

    of this study was to model a dead fuel load based on forest mensuration attributes from forest management from management programs are an efficient and low-cost alternative for estimating forest fuel loadsGENERAL TECHNICAL REPORT PSW-GTR-245 274 Fuel Load Modeling From Mensuration Attributes

  19. Autonomous Network Management Using Cooperative Learning for Network-Wide Load

    E-Print Network [OSTI]

    Yoo, S. J. Ben

    Autonomous Network Management Using Cooperative Learning for Network-Wide Load Balancing-wide load balance, we propose Autonomous Network management with Team learning based Self shortest paths while uncongested longer paths may be underutilized. To maintain network-wide load balancing

  20. Optically Loaded Semiconductor Quantum Memory Register

    E-Print Network [OSTI]

    Danny Kim; Andrey A. Kiselev; Richard S. Ross; Matthew T. Rakher; Cody Jones; Thaddeus D. Ladd

    2015-07-30

    We propose and analyze an optically loaded quantum memory exploiting capacitive coupling between self-assembled quantum dot molecules and electrically gated quantum dot molecules. The self-assembled dots are used for spin-photon entanglement, which is transferred to the gated dots for long-term storage or processing via a teleportation process heralded by single-photon detection. We illustrate a device architecture enabling this interaction and we outline its operation and fabrication. We provide self-consistent Poisson-Schroedinger simulations to establish the design viability and refine the design, and to estimate the physical coupling parameters and their sensitivities to dot placement. The device we propose generates heralded copies of an entangled state between a photonic qubit and a solid-state qubit with a rapid reset time upon failure. The resulting fast rate of entanglement generation is of high utility for heralded quantum networking scenarios involving lossy optical channels.

  1. SU-E-J-73: Generation of Volumetric Images with a Respiratory Motion Model Based On An External Surrogate Signal

    SciTech Connect (OSTI)

    Hurwitz, M; Williams, C; Mishra, P; Dhou, S; Lewis, J

    2014-06-01

    Purpose: Respiratory motion during radiotherapy treatment can differ significantly from motion observed during imaging for treatment planning. Our goal is to use an initial 4DCT scan and the trace of an external surrogate marker to generate 3D images of patient anatomy during treatment. Methods: Deformable image registration is performed on images from an initial 4DCT scan. The deformation vectors are used to develop a patient-specific linear relationship between the motion of each voxel and the trajectory of an external surrogate signal. Correlations in motion are taken into account with principal component analysis, reducing the number of free parameters. This model is tested with digital phantoms reproducing the breathing patterns of ten measured patient tumor trajectories, using five seconds of data to develop the model and the subsequent thirty seconds to test its predictions. The model is also tested with a breathing physical anthropomorphic phantom programmed to reproduce a patient breathing pattern. Results: The error (mean absolute, 95th percentile) over 30 seconds in the predicted tumor centroid position ranged from (0.8, 1.3) mm to (2.2, 4.3) mm for the ten patient breathing patterns. The model reproduced changes in both phase and amplitude of the breathing pattern. Agreement between prediction and truth over the entire image was confirmed by assessing the global voxel intensity RMS error. In the physical phantom, the error in the tumor centroid position was less than 1 mm for all images. Conclusion: We are able to reconstruct 3D images of patient anatomy with a model correlating internal respiratory motion with motion of an external surrogate marker, reproducing the expected tumor centroid position with an average accuracy of 1.4 mm. The images generated by this model could be used to improve dose calculations for treatment planning and delivered dose estimates. This work was partially funded by a research grant from Varian Medical Systems.

  2. CNTS: Memory-Based Learning of Generating Repeated References Iris Hendrickx, Walter Daelemans, Kim Luyckx, Roser Morante, Vincent Van Asch

    E-Print Network [OSTI]

    learning approach to the task. We train a classifier to predict the correct label for each mention. As our machine learning algorithm we use memory-based learn- ing as implemented in the Timbl package (Daele- mans learning algorithms implemented in the Weka package (Witten and Frank, 2005), but these experiments did

  3. Evaluation of a new model to calculate direct normal irradiance based on satellite images of Meteosat Second Generation

    E-Print Network [OSTI]

    Heinemann, Detlev

    Evaluation of a new model to calculate direct normal irradiance based on satellite images irradiance DNI from MSG data. For this we apply the Heliosat method to extract cloudiness from the satellite of the irradiance is introduced to calculate DNI. The clear sky irradiance is mainly determined by the aerosol

  4. Distributed Generation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Electricity, US Data. 6. Distributed Generation: Standby Generation and Cogeneration Ozz Energy Solutions, Inc. February 28 th , 2005. For more information about...

  5. Fuel Cell Power Model Version 2: Startup Guide, System Designs, and Case Studies. Modeling Electricity, Heat, and Hydrogen Generation from Fuel Cell-Based Distributed Energy Systems

    SciTech Connect (OSTI)

    Steward, D.; Penev, M.; Saur, G.; Becker, W.; Zuboy, J.

    2013-06-01

    This guide helps users get started with the U.S. Department of Energy/National Renewable Energy Laboratory Fuel Cell Power (FCPower) Model Version 2, which is a Microsoft Excel workbook that analyzes the technical and economic aspects of high-temperature fuel cell-based distributed energy systems with the aim of providing consistent, transparent, comparable results. This type of energy system would provide onsite-generated heat and electricity to large end users such as hospitals and office complexes. The hydrogen produced could be used for fueling vehicles or stored for later conversion to electricity.

  6. Frequency regulator for synchronous generators

    DOE Patents [OSTI]

    Karlicek, R.F.

    1982-08-10

    The present invention is directed to a novel frequency regulator which controls a generator output frequency for variations in both the input power to the generator and the power supplied to an uncontrolled external load. The present invention further includes over current and current balance protection devices which are relatively inexpensive to manufacture, which may be encapsulated to provide protection from the operating environment and which respond more quickly than previously known electromechanical devices. 11 figs.

  7. Frequency regulator for synchronous generators

    DOE Patents [OSTI]

    Karlicek, Robert F. (1920 Camino Centroloma, Fullerton, CA 92633)

    1982-01-01

    The present invention is directed to a novel frequency regulator which controls a generator output frequency for variations in both the input power to the generator and the power supplied to an uncontrolled external load. The present invention further includes over current and current balance protection devices which are relatively inexpensive to manufacture, which may be encapsulated to provide protection from the operating environment and which respond more quickly than previously known electromechanical devices.

  8. Solid state pulsed power generator

    DOE Patents [OSTI]

    Tao, Fengfeng; Saddoughi, Seyed Gholamali; Herbon, John Thomas

    2014-02-11

    A power generator includes one or more full bridge inverter modules coupled to a semiconductor opening switch (SOS) through an inductive resonant branch. Each module includes a plurality of switches that are switched in a fashion causing the one or more full bridge inverter modules to drive the semiconductor opening switch SOS through the resonant circuit to generate pulses to a load connected in parallel with the SOS.

  9. Supplying Renewable Energy to Deferrable Loads: Algorithms and Economic Analysis

    E-Print Network [OSTI]

    Oren, Shmuel S.

    Supplying Renewable Energy to Deferrable Loads: Algorithms and Economic Analysis Anthony compares to price responsive demand in terms capacity gains and energy market revenues for renewable to renewable generation. I. INTRODUCTION Renewable power is emerging as a mainstream source of energy supply

  10. Compact D-D/D-T neutron generators and their applications

    E-Print Network [OSTI]

    Lou, T P

    2003-01-01

    Neutron generators based on the sup 2 H(d,n) sup 3 He and sup 3 H(d,n) sup 4 He fusion reactions are the most commonly available neutron sources. The applications of current commercial neutron generators are often limited by their low neutron yield and their short operational lifetime. A new generation of D-D/D-T fusion-based neutron generators has been designed at Lawrence Berkeley National Laboratory (LBNL) by using high current ion beams hitting on a self-loading target that has a large surface area to dissipate the heat load. This thesis describes the rationale behind the new designs and their potential applications. A survey of other neutron sources is presented to show their advantages and disadvantages compared to the fusion-based neutron generator. A prototype neutron facility was built at LBNL to test these neutron generators. High current ion beams were extracted from an RF-driven ion source to produce neutrons. With an average deuteron beam current of 24 mA and an energy of 100 keV, a neutron yield...

  11. A free-piston Stirling engine/linear alternator controls and load interaction test facility

    SciTech Connect (OSTI)

    Rauch, J.S.; Kankam, M.D.; Santiago, W.; Madi, F.J.

    1992-08-01

    A test facility at LeRC was assembled for evaluating free-piston Stirling engine/linear alternator control options, and interaction with various electrical loads. This facility is based on a 'SPIKE' engine/alternator. The engine/alternator, a multi-purpose load system, a digital computer based load and facility control, and a data acquisition system with both steady-periodic and transient capability are described. Preliminary steady-periodic results are included for several operating modes of a digital AC parasitic load control. Preliminary results on the transient response to switching a resistive AC user load are discussed.

  12. Spinning Reserve from Responsive Load

    SciTech Connect (OSTI)

    Kueck, John D; Kirby, Brendan J; Laughner, T; Morris, K

    2009-01-01

    As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host a spinning reserve test. The Tennessee Valley Authority (TVA) supplied real-time metering and monitoring expertise to record total hotel load during both normal operations and testing. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. The load drop was very rapid, essentially as fast as the 2 second metering could detect.

  13. 94 M. SIMKA, M. DRUTAROVSK Y, V. FISCHER, OBSERVING PLL-BASED TRNG IN CHANGING WORKING CONDITIONS Testing of PLL-based True Random Number Generator

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    94 M. SIMKA, M. DRUTAROVSK ´Y, V. FISCHER, OBSERVING PLL-BASED TRNG IN CHANGING WORKING CONDITIONS DRUTAROVSK ´Y 2, Viktor FISCHER 3 1 Datel, Drawska 10/17, 02-202 Warsaw, Poland 2 Dept. of Electronics. info@martinsimka.com, Milos.Drutarovsky@tuke.sk, fischer@univ-st-etienne.fr Abstract. Security

  14. Thermogravitational cycles: theoretical framework and example of an electric thermogravitational generator based on balloon inflation/deflation

    E-Print Network [OSTI]

    Kamel Aouane; Olivier Sandre; Ian J. Ford; Tim P. Elson; Christopher Nightingale

    2015-11-03

    Several studies have combined heat and gravitational energy exchanges to create novel heat engines. A common theoretical framework is developed here to describe thermogravitational cycles which have the same efficiencies as the Carnot, Rankine or Brayton cycles. Considering a working fluid, enclosed in a balloon, inside a column filled with a transporting fluid, the cycle is composed of four steps. Starting from the top of the column, the balloon goes down, receives heat from a hot source at the bottom, rises and delivers heat to a cold source at the top. Unlike classic power cycles which need external work to operate the compressor, thermogravitational cycles can operate as "pure power cycle" where no work is provided to drive the cycle. To illustrate this concept, the prototype of a thermogravitational electrical generator is presented. It uses a hot source of low temperature (average temperature near 57{\\deg}C) and relies on the gravitational energy exchanges of an organic fluid inside a balloon attached to a magnetic marble to produce an electromotive force of 50 mV peak to peak by using a linear alternator. This heat engine is well suited to be operated using renewable energy sources such as geothermal gradients or focused sunbeams.

  15. Thermogravitational cycles: theoretical framework and example of an electric thermogravitational generator based on balloon inflation/deflation

    E-Print Network [OSTI]

    Aouane, Kamel; Ford, Ian J; Elson, Tim P; Nightingale, Christopher

    2015-01-01

    Several studies have combined heat and gravitational energy exchanges to create novel heat engines. A common theoretical framework is developed here to describe thermogravitational cycles which have the same efficiencies as the Carnot, Rankine or Brayton cycles. Considering a working fluid, enclosed in a balloon, inside a column filled with a transporting fluid, the cycle is composed of four steps. Starting from the top of the column, the balloon goes down, receives heat from a hot source at the bottom, rises and delivers heat to a cold source at the top. Unlike classic power cycles which need external work to operate the compressor, thermogravitational cycles can operate as "pure power cycle" where no work is provided to drive the cycle. To illustrate this concept, the prototype of a thermogravitational electrical generator is presented. It uses a hot source of low temperature (average temperature near 57{\\deg}C) and relies on the gravitational energy exchanges of an organic fluid inside a balloon attached t...

  16. Model Development and Loads Analysis of an Offshore Wind Turbine on a Tension Leg Platform with a Comparison to Other Floating Turbine Concepts: April 2009

    SciTech Connect (OSTI)

    Matha, D.

    2010-02-01

    This report presents results of the analysis of a 5-MW wind turbine located on a floating offshore tension leg platform (TLP) that was conducted using the fully coupled time-domain aero-hydro-servo-elastic design code FAST with AeroDyn and HydroDyn. The report also provides a description of the development process of the TLP model. The model has been verified via comparisons to frequency-domain calculations. Important differences have been identified between the frequency-domain and time-domain simulations, and have generated implications for the conceptual design process. An extensive loads and stability analysis for ultimate and fatigue loads according to the procedure of the IEC 61400-3 offshore wind turbine design standard was performed with the verified TLP model. This report compares the loads for the wind turbine on the TLP to those of an equivalent land-based turbine. Major instabilities for the TLP are identified and described.

  17. Seismic Loading for FAST: May 2011 - August 2011

    SciTech Connect (OSTI)

    Asareh, M. A.; Prowell, I.

    2012-08-01

    As more wind farms are constructed in seismically active regions, earthquake loading increases in prominence for design and analysis of wind turbines. Early investigation of seismic load tended to simplify the rotor and nacelle as a lumped mass on top of the turbine tower. This simplification allowed the use of techniques developed for conventional civil structures, such as buildings, to be easily applied to wind turbines. However, interest is shifting to more detailed models that consider loads for turbine components other than the tower. These improved models offer three key capabilities in consideration of base shaking for turbines: 1) The inclusion of aerodynamics and turbine control; 2) The ability to consider component loads other than just tower loads; and 3) An improved representation of turbine response in higher modes by reducing modeling simplifications. Both experimental and numerical investigations have shown that, especially for large modern turbines, it is important to consider interaction between earthquake input, aerodynamics, and operational loads. These investigations further show that consideration of higher mode activity may be necessary in the analysis of the seismic response of turbines. Since the FAST code is already capable of considering these factors, modifications were developed that allow simulation of base shaking. This approach allows consideration of this additional load source within a framework, the FAST code that is already familiar to many researchers and practitioners.

  18. 1994 Pacific Northwest Loads and Resources Study, Technical Appendix: Volume 1.

    SciTech Connect (OSTI)

    United States. Bonneville Power Administration.

    1994-12-01

    The 1994 Pacific Northwest Loads and Resources Study establishes the Bonneville Power Administration`s (BPA) planning basis for supplying electricity t6 BPA customers. The Loads and Resources Study is presented in two documents: (1) this technical appendix detailing loads and resources for each major Pacific Northwest generating utility; and (2) a summary of Federal system and Pacific Northwest region loads and resources. This analysis updates the 1993 Pacific Northwest Loads and Resources Study Technical Appendix published in December 1993. This technical appendix provides utility specific information that BPA uses in its long-range planning. It incorporates the following for each utility: (1) electrical demand-firm loads; (2) generating resources; and (3) contracts both inside and outside the region. This document should be used in combination with the 1994 Pacific Northwest Loads and Resources Study, published in December 1994, because much of the information in that document is not duplicated here. This BPA planning document incorporates Pacific Northwest generating resources and the 1994 medium load forecast prepared by BPA. Each utility`s forecasted future firm loads are subtracted from its existing resources to determine whether it will be surplus or deficit. If a utility`s resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which the utility can sell to increase revenues. Conversely, if its firm loads exceed available resources, there is a deficit of energy and/or capacity, and additional conservation, contract purchases, or generating resources will be needed to meet the utility`s load.

  19. Motor/generator

    DOE Patents [OSTI]

    Hickam, Christopher Dale (Glasford, IL)

    2008-05-13

    A motor/generator is provided for connecting between a transmission input shaft and an output shaft of a prime mover. The motor/generator may include a motor/generator housing, a stator mounted to the motor/generator housing, a rotor mounted at least partially within the motor/generator housing and rotatable about a rotor rotation axis, and a transmission-shaft coupler drivingly coupled to the rotor. The transmission-shaft coupler may include a clamp, which may include a base attached to the rotor and a plurality of adjustable jaws.

  20. D0 Silicon Upgrade: Lower Cleanroom Roof Quick Load Analysis

    SciTech Connect (OSTI)

    Rucinski, Russ; /Fermilab

    1995-11-17

    This engineering note documents calculations done to determine the margin of safety for the lower clean room roof. The analysis was done to give me a feeling of what the loads, stresses and capacity of the roof is prior to installation and installation work to be done for the helium refrigerator upgrade. The result of this quick look showed that the calculated loads produce stress values and loads at about half the allowables. Based on this result, I do not think that special precautions above personal judgement are required for the installation work.

  1. Sandia Wind Turbine Loads Database

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    The Sandia Wind Turbine Loads Database is divided into six files, each corresponding to approximately 16 years of simulation. The files are text files with data in columnar format. The 424MB zipped file containing six data files can be downloaded by the public. The files simulate 10-minute maximum loads for the NREL 5MW wind turbine. The details of the loads simulations can be found in the paper: “Decades of Wind Turbine Loads Simulations”, M. Barone, J. Paquette, B. Resor, and L. Manuel, AIAA2012-1288 (3.69MB PDF). Note that the site-average wind speed is 10 m/s (class I-B), not the 8.5 m/s reported in the paper.

  2. Building load control and optimization

    E-Print Network [OSTI]

    Xing, Hai-Yun Helen, 1976-

    2004-01-01

    Researchers and practitioners have proposed a variety of solutions to reduce electricity consumption and curtail peak demand. This research focuses on load control by improving the operations in existing building HVAC ...

  3. Loading and conjugating cavity biostructures

    DOE Patents [OSTI]

    Hainfeld, J.F.

    1997-11-25

    Methods for the preparation and use of a biological delivery system are disclosed. The method of preparation includes the loading of a non-biological material into a biostructure having a load-bearing structure. The method also includes the removal of some of the biostructure`s contents and the loading of a non-biological material into the biostructure. The biostructure is biologically compatible with the host, and preferably is derived from the host, the host`s species or a related species. The loaded biostructure is used directly, or it can be targeted to specific cells, tissues and/or organs within a host. The targeted biostructure can be used to deliver the non-biological material to a specified tissue, organ or cell within a host for diagnostic, therapeutic or other purposes. 11 figs.

  4. High-efficiency micro-energy generation based on free-carrier-modulated ZnO:N piezoelectric thin films

    SciTech Connect (OSTI)

    Lee, Eunju; Park, Jaedon; Yim, Munhyuk; Jeong, Sangbeom; Yoon, Giwan, E-mail: gwyoon@kaist.ac.kr [Department of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of)

    2014-05-26

    The free-carrier-modulated ZnO:N thin film-based flexible nanogenerators (NZTF-FNGs) are proposed and experimentally demonstrated. The suggested flexible nanogenerators (FNGs) are fabricated using N-doped ZnO thin films (NZTFs) as their piezoelectric active elements, which are deposited by a radio frequency magnetron sputtering technique with an N{sub 2}O reactive gas as an in situ dopant source. Considerable numbers of N atoms are uniformly incorporated into NZTFs overall during their growth, which would enable them to significantly compensate the unintentional background free electron carriers both in the bulk and at the surface of ZnO thin films (ZTFs). This N-doping approach is found to remarkably enhance the performance of NZTF-FNGs, which shows output voltages that are almost two orders of magnitude higher than those of the conventionally grown ZnO thin film-based FNGs. This is believed to be a result of both substantial screening effect suppression in the ZTF bulk and more reliable Schottky barrier formation at the ZTF interfaces, which is all mainly caused by the N-compensatory doping process. Furthermore, the NZTF-FNGs fabricated are verified via charging tests to be suitable for micro-energy harvesting devices.

  5. Methodology and a preliminary data base for examining the health risks of electricity generation from uranium and coal fuels

    SciTech Connect (OSTI)

    El-Bassioni, A.A.

    1980-08-01

    An analytical model was developed to assess and examine the health effects associated with the production of electricity from uranium and coal fuels. The model is based on a systematic methodology that is both simple and easy to check, and provides details about the various components of health risk. A preliminary set of data that is needed to calculate the health risks was gathered, normalized to the model facilities, and presented in a concise manner. Additional data will become available as a result of other evaluations of both fuel cycles, and they should be included in the data base. An iterative approach involving only a few steps is recommended for validating the model. After each validation step, the model is improved in the areas where new information or increased interest justifies such upgrading. Sensitivity analysis is proposed as the best method of using the model to its full potential. Detailed quantification of the risks associated with the two fuel cycles is not presented in this report. The evaluation of risks from producing electricity by these two methods can be completed only after several steps that address difficult social and technical questions. Preliminary quantitative assessment showed that several factors not considered in detail in previous studies are potentially important. 255 refs., 21 figs., 179 tabs.

  6. Demand Response: Load Management Programs 

    E-Print Network [OSTI]

    Simon, J.

    2012-01-01

    Management Programs CATEE Conference October, 2012 Agenda Outline I. General Demand Response Definition II. General Demand Response Program Rules III. CenterPoint Commercial Program IV. CenterPoint Residential Programs V. Residential Discussion... Points Demand Response Definition of load management per energy efficiency rule 25.181: ? Load control activities that result in a reduction in peak demand, or a shifting of energy usage from a peak to an off-peak period or from high-price periods...

  7. Structural assessment of accident loads

    SciTech Connect (OSTI)

    Wagenblast, G.R., Westinghouse Hanford

    1996-05-28

    Structural assessments were made for specific accident loads for specific catch, receiver, and storage tanks. The evaluation herein represents level-of-effort order-of-magnitude estimates of limiting loads that would lead to collapse or rupture of the tank and unmitigated loss of confinement for the waste. Structural capacities were established using failure criteria. Compliance with codes such as ACI, ASCE, ASME, RCRA, UBC, WAC, and DOE Orders was `NOT` maintained. Normal code practice is to prevent failure with margins consistent with expected variations in loads and strengths and confidence in analysis techniques. The evaluation herein represent estimates of code limits without code load factors or code strength reduction factors, and loading beyond such a limit is considered as an onset of some failure mode. The exact nature of the failure mode and its relation to a safe condition is a judgment of the analyst. Consequently, these `RESULTS SHALL NOT BE USED TO ESTABLISH OPERATING OR SAFETY LOAD LIMITS FOR THESE TANKS`.

  8. EECS 598 Special Topic Analysis of Electric Power Distribution Systems and Loads

    E-Print Network [OSTI]

    Cafarella, Michael J.

    and Loads Mondays and Wednesdays, 9:00am-10:30am, EECS Building 3427 Fall 2014; however, with increased amounts of distributed generation (photovoltaics, small-scale wind), distributed storage, and controllable loads, it has become more and more

  9. Modeling Long-term Creep Performance for Welded Nickel-base Superalloy Structures for Power Generation Systems

    SciTech Connect (OSTI)

    Shen, Chen

    2015-01-01

    We report here a constitutive model for predicting long-term creep strain evolution in ?’ strengthened Ni-base superalloys. Dislocation climb-bypassing ?’, typical in intermediate ?’ volume fraction (~20%) alloys, is considered as the primary deformation mechanism. Dislocation shearing ?’ to anti-phase boundary (APB) faults and diffusional creep are also considered for high-stress and high-temperature low-stress conditions, respectively. Additional damage mechanism is taken into account for rapid increase in tertiary creep strain. The model has been applied to Alloy 282, and calibrated in a temperature range of 1375-1450?F, and stress range of 15-45ksi. The model parameters and a MATLAB code are provided. This report is prepared by Monica Soare and Chen Shen at GE Global Research. Technical discussions with Dr. Vito Cedro are greatly appreciated. This work was supported by DOE program DE-FE0005859

  10. Distributed Generation Dispatch Optimization under Various Electricity Tariffs

    E-Print Network [OSTI]

    Firestone, Ryan; Marnay, Chris

    2007-01-01

    to solar insolation. Energy Prices Electricity prices weresolar insolation that are based on these data. Energy Loads Utility electricityenergy loads (non- cooling electric, electric, and heating), electricity prices, DG availability, and solar

  11. Cooling load design tool for UFAD systems.

    E-Print Network [OSTI]

    Bauman, Fred; Schiavon, Stefano; Webster, Tom; Lee, Kwang Ho

    2010-01-01

    De- velopment of a Simplified Cooling Load Design Tool forand C. Benedek. 2007. “Cooling airflow design calculationscalculation method for design cooling loads in underfloor

  12. Laser Driven Dynamic Loading of Condensed Matter

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Laser Driven Dynamic Loading of Condensed Matter Laser Driven Dynamic Loading of Condensed Matter Advanced diagnostics of experiments covering many orders of magnitude in strain...

  13. Load Participation in Ancillary Services Workshop Report

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    controls on the load-side is growing. Driven by improved and widely available communications systems, load participation is becoming easier and more reliable; and there...

  14. Self-aligning biaxial load frame

    DOE Patents [OSTI]

    Ward, M.B.; Epstein, J.S.; Lloyd, W.R.

    1994-01-18

    An self-aligning biaxial loading apparatus for use in testing the strength of specimens while maintaining a constant specimen centroid during the loading operation. The self-aligning biaxial loading apparatus consists of a load frame and two load assemblies for imparting two independent perpendicular forces upon a test specimen. The constant test specimen centroid is maintained by providing elements for linear motion of the load frame relative to a fixed cross head, and by alignment and linear motion elements of one load assembly relative to the load frame. 3 figures.

  15. Effects of rotor tip blade loading variation on compressor stage performance

    E-Print Network [OSTI]

    Tiralap, Aniwat

    2015-01-01

    Changes in loss generation associated with altering the rotor tip loading of an embedded compressor stage is assessed. Steady and unsteady three-dimensional computations, complemented by control volume analyses, for varying ...

  16. Rigid-Plastic Approximations for Predicting Plastic Deformation of Cylindrical Shells Subject to Dynamic Loading

    E-Print Network [OSTI]

    Hoo Fatt, Michelle S.

    A theoretical approach was developed for predicting the plastic deformation of a cylindrical shell subject to asymmetric dynamic loads. The plastic deformation of the leading generator of the shell is found by solving for ...

  17. Elastic modulus mapping of atomically thin film based Lithium Ion Battery electrodes Lithium Ion Batteries (LIB) are one of the most promising class of next generation energy storage devices,

    E-Print Network [OSTI]

    Batteries (LIB) are one of the most promising class of next generation energy storage devices, which can producing more reliable and promising LIB based clean energy storage devices. The CR-AFM (Contact Resonance

  18. Real-time POD-CFD Wind-Load Calculator for PV Systems

    SciTech Connect (OSTI)

    Huayamave, Victor; Divo, Eduardo; Ceballos, Andres; Barriento, Carolina; Stephen, Barkaszi; Hubert, Seigneur

    2014-03-21

    The primary objective of this project is to create an accurate web-based real-time wind-load calculator. This is of paramount importance for (1) the rapid and accurate assessments of the uplift and downforce loads on a PV mounting system, (2) identifying viable solutions from available mounting systems, and therefore helping reduce the cost of mounting hardware and installation. Wind loading calculations for structures are currently performed according to the American Society of Civil Engineers/ Structural Engineering Institute Standard ASCE/SEI 7; the values in this standard were calculated from simplified models that do not necessarily take into account relevant characteristics such as those from full 3D effects, end effects, turbulence generation and dissipation, as well as minor effects derived from shear forces on installation brackets and other accessories. This standard does not include provisions that address the special requirements of rooftop PV systems, and attempts to apply this standard may lead to significant design errors as wind loads are incorrectly estimated. Therefore, an accurate calculator would be of paramount importance for the preliminary assessments of the uplift and downforce loads on a PV mounting system, identifying viable solutions from available mounting systems, and therefore helping reduce the cost of the mounting system and installation. The challenge is that although a full-fledged three-dimensional computational fluid dynamics (CFD) analysis would properly and accurately capture the complete physical effects of air flow over PV systems, it would be impractical for this tool, which is intended to be a real-time web-based calculator. CFD routinely requires enormous computation times to arrive at solutions that can be deemed accurate and grid-independent even in powerful and massively parallel computer platforms. This work is expected not only to accelerate solar deployment nationwide, but also help reach the SunShot Initiative goals of reducing the total installed cost of solar energy systems by 75%. The largest percentage of the total installed cost of solar energy system is associated with balance of system cost, with up to 40% going to “soft” costs; which include customer acquisition, financing, contracting, permitting, interconnection, inspection, installation, performance, operations, and maintenance. The calculator that is being developed will provide wind loads in real-time for any solar system designs and suggest the proper installation configuration and hardware; and therefore, it is anticipated to reduce system design, installation and permitting costs.

  19. Economic feasibility analysis of distributed electric power generation based upon the natural gas-fired fuel cell. Final report

    SciTech Connect (OSTI)

    Not Available

    1994-03-01

    The final report provides a summary of results of the Cost of Ownership Model and the circumstances under which a distributed fuel cell is economically viable. The analysis is based on a series of micro computer models estimate the capital and operations cost of a fuel cell central utility plant configuration. Using a survey of thermal and electrical demand profiles, the study defines a series of energy user classes. The energy user class demand requirements are entered into the central utility plant model to define the required size the fuel cell capacity and all supporting equipment. The central plant model includes provisions that enables the analyst to select optional plant features that are most appropriate to a fuel cell application, and that are cost effective. The model permits the choice of system features that would be suitable for a large condominium complex or a residential institution such as a hotel, boarding school or prison. Other applications are also practical; however, such applications have a higher relative demand for thermal energy, a characteristic that is well-suited to a fuel cell application with its free source of hot water or steam. The analysis combines the capital and operation from the preceding models into a Cost of Ownership Model to compute the plant capital and operating costs as a function of capacity and principal features and compares these estimates to the estimated operating cost of the same central plant configuration without a fuel cell.

  20. Staying FIT: Efficient Load Shedding Techniques for Distributed Stream Processing

    E-Print Network [OSTI]

    . Bottlenecks slow down processing and network transmission, and cause delayed outputs. Load management has been. Common load management techniques include adaptive load distribution, admis- sion control, and load

  1. Dual Baud Rate Generator Programmable Divider

    E-Print Network [OSTI]

    Mann, Tim

    to excessive loading. The output of the oscillatorlbuffer is applied to the dividers for generation, inclusive. If the divisor is even, the output will be square: otherwise the output will be high longer thanAPPENDIX B #12;#12;Dual Baud Rate Generator Programmable Divider FEATURES PIN CONFi

  2. Adaptive Load Forecasting Philip Anton de Saint-Aubain

    E-Print Network [OSTI]

    of Denmark Informatics and Mathematical Modelling Building 321, DK-2800 Kongens Lyngby, Denmark Phone +45 with renewable energy. Renewable energy in Denmark is mostly based on wind power which is a highly fluctuating mathematical models for the heat load. Based on district heating consumption data from four houses in a small

  3. Avoiding Distribution System Upgrade Costs Using Distributed Generation

    SciTech Connect (OSTI)

    Schienbein, Lawrence A.; Balducci, Patrick J.; Nguyen, Tony B.; Brown, Daryl R.; DeSteese, John G.; Speer, Gregory A.

    2004-01-20

    PNNL, in cooperation with three utilities, developed a database and methodology to analyze and characterize the avoided costs of Distributed Generation (DG) deployment as an alternative to traditional distribution system investment. After applying a number of screening criteria to the initial set of 307 cases, eighteen were selected for detailed analysis. Alternative DG investment scenarios were developed for these cases to permit capital, operation, maintenance, and fuel costs to be identified and incorporated into the analysis. The “customer-owned” backup power generator option was also investigated. The results of the analysis of the 18 cases show that none yielded cost savings under the alternative DG scenarios. However, the DG alternative systems were configured using very restrictive assumptions concerning reliability, peak rating, engine types and acceptable fuel. In particular it was assumed that the DG alternative in each case must meet the reliability required of conventional distribution systems (99.91% reliability). The analysis was further constrained by a requirement that each substation meet the demands placed upon it by a one in three weather occurrence. To determine if, by relaxing these requirements, the DG alternative might be more viable, one project was re-examined. The 99.91% reliability factor was still assumed for normal operating conditions but redundancy required to maintain reliability was relaxed for the relatively few hours every three years where extreme weather caused load to exceed present substation capacity. This resulted in the deferment of capital investment until later years and reduced the number of engines required for the project. The cost of both the conventional and DG alternative also dropped because the centralized power generation, variable O&M, and DG fuels costs were calculated based on present load requirements in combination with long-term forecasts of load growth, as opposed to load requirements plus a buffer based on predictions of extraordinary weather conditions. Application of the relaxed set of assumptions reduced the total cost of the DG alternative by roughly 57 percent from $7.0 million to $3.0 million. The reduction, however, did not change the overall result of the analysis, as the cost of the conventional distribution system upgrade alternative remained lower at $1.7 million. This paper also explores the feasibility of using a system of backup generators to defer investment in distribution system infrastructure. Rather than expanding substation capacity at substations experiencing slow load growth rates, PNNL considered a scenario where diesel generators were installed on location at customers participating in a program designed to offer additional power security and reliability to the customer and connection to the grid. The backup generators, in turn, could be used to meet peak demand for a limited number of hours each year, thus deferring distribution system investment. Data from an existing program at one of the three participating utilities was used to quantify the costs associated with the backup generator scenario. The results of the “customer owned” backup power generator analysis showed that in all cases the nominal cost of the DG scenario is more than the nominal cost of the base-case conventional distribution system upgrade scenario. However, in two of the cases the total present value costs of the alternative backup generator scenarios were between 15 and 22% less than those for the conventional scenarios. Overall, the results of the study offer considerable encouragement that the use of DG systems can defer conventional distribution system upgrades under the right conditions and when the DG configurations are intelligently designed. Using existing customer-owned DG to defer distribution system upgrades appears to be an immediate commercially-viable opportunity.

  4. Assessment of Industrial Load for Demand Response across U.S. Regions of the Western Interconnection

    Broader source: Energy.gov [DOE]

    Demand response has the ability to both increase power grid reliability and potentially reduce operating system costs. Understanding the role of demand response in grid modeling has been difficult due to complex nature of the load characteristics compared to the modeled generation and the variation in load types. This is particularly true of industrial loads, where hundreds of different industries exist with varying availability for demand response. We present a framework considering industrial loads for the development of availability profiles for demand response that can provide more regional understanding and can be inserted into analysis software for further study.

  5. Benefits of Industrial Boiler Control and Economic Load Allocation at AMOCO Chemicals, Decatur, Alabama 

    E-Print Network [OSTI]

    Winter, J.

    1998-01-01

    , it is considered by this solution. The global solution makes recommendations to advise the operator as to what the optimum loading is for all the boilers, including recommending adding or removing boilers from service, and changing the load on any base-loaded... as long as the soluti os remain valid, as defmed above. To achieve savings from the local soluti n optimization, the boiler loads must be altered fr~m the traditional, non-optimized loading strategy 0 a common plant master signal cascaded to all boil...

  6. Ultra-low phase-noise microwave generation using a diode-pumped solid-state laser based frequency comb and a polarization-maintaining pulse interleaver

    E-Print Network [OSTI]

    Portuondo-Campa, Erwin; Kundermann, Stefan; Balet, Laurent; Lecomte, Steve

    2015-01-01

    We report ultra-low phase-noise microwave generation at a 9.6 GHz carrier frequency from optical frequency combs based on diode-pumped solid-state lasers emitting at telecom wavelength and referenced to a common cavity-stabilized continuous-wave laser. Using a novel fibered polarization-maintaining pulse interleaver, a single-oscillator phase-noise floor of -171 dBc/Hz has been measured with commercial PIN InGaAs photodiodes, constituting a record for this type of detector. Also, a direct optical measurement of the stabilized frequency combs timing jitter was performed using a balanced optical cross correlator, allowing for an identification of the origin of the current phase-noise limitations in the system.

  7. Noise Load Management at Amsterdam Airport Schiphol

    E-Print Network [OSTI]

    Boucherie, Richard J.

    Noise Load Management at Amsterdam Airport Schiphol T.R. Meerburg , R.J. Boucherie , M.J.A.L. van objective is to guarantee safety, efficiency, and protection of the environment, that includes noise load contributes to the noise load at these points. If the cumulative load in an aviation year at an enforce- ment

  8. Active load control techniques for wind turbines.

    SciTech Connect (OSTI)

    van Dam, C.P.; Berg, Dale E.; Johnson, Scott J.

    2008-07-01

    This report provides an overview on the current state of wind turbine control and introduces a number of active techniques that could be potentially used for control of wind turbine blades. The focus is on research regarding active flow control (AFC) as it applies to wind turbine performance and loads. The techniques and concepts described here are often described as 'smart structures' or 'smart rotor control'. This field is rapidly growing and there are numerous concepts currently being investigated around the world; some concepts already are focused on the wind energy industry and others are intended for use in other fields, but have the potential for wind turbine control. An AFC system can be broken into three categories: controls and sensors, actuators and devices, and the flow phenomena. This report focuses on the research involved with the actuators and devices and the generated flow phenomena caused by each device.

  9. Comparison of Wind Power and Load Forecasting Error Distributions: Preprint

    SciTech Connect (OSTI)

    Hodge, B. M.; Florita, A.; Orwig, K.; Lew, D.; Milligan, M.

    2012-07-01

    The introduction of large amounts of variable and uncertain power sources, such as wind power, into the electricity grid presents a number of challenges for system operations. One issue involves the uncertainty associated with scheduling power that wind will supply in future timeframes. However, this is not an entirely new challenge; load is also variable and uncertain, and is strongly influenced by weather patterns. In this work we make a comparison between the day-ahead forecasting errors encountered in wind power forecasting and load forecasting. The study examines the distribution of errors from operational forecasting systems in two different Independent System Operator (ISO) regions for both wind power and load forecasts at the day-ahead timeframe. The day-ahead timescale is critical in power system operations because it serves the unit commitment function for slow-starting conventional generators.

  10. Parallel performance optimizations on unstructured mesh-based simulations

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Sarje, Abhinav; Song, Sukhyun; Jacobsen, Douglas; Huck, Kevin; Hollingsworth, Jeffrey; Malony, Allen; Williams, Samuel; Oliker, Leonid

    2015-06-01

    This paper addresses two key parallelization challenges the unstructured mesh-based ocean modeling code, MPAS-Ocean, which uses a mesh based on Voronoi tessellations: (1) load imbalance across processes, and (2) unstructured data access patterns, that inhibit intra- and inter-node performance. Our work analyzes the load imbalance due to naive partitioning of the mesh, and develops methods to generate mesh partitioning with better load balance and reduced communication. Furthermore, we present methods that minimize both inter- and intranode data movement and maximize data reuse. Our techniques include predictive ordering of data elements for higher cache efficiency, as well as communication reduction approaches.more »We present detailed performance data when running on thousands of cores using the Cray XC30 supercomputer and show that our optimization strategies can exceed the original performance by over 2×. Additionally, many of these solutions can be broadly applied to a wide variety of unstructured grid-based computations.« less

  11. Load controller and method to enhance effective capacity of a photovoltaic power supply

    DOE Patents [OSTI]

    Perez, Richard (Delmar, NY)

    2000-01-01

    A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply. The renewable supply may comprise, for example, a photovoltaic power supply or a wind-based power supply.

  12. Durham University, School of Engineering, Low Voltage Micro-generation Laboratory

    E-Print Network [OSTI]

    Wirosoetisno, Djoko

    designed at Durham University for use in a vertical axis wind turbine is used in conjunction micro-generation laboratory consists of one load emulator, one wind turbine generator emulator, one PV, frequency etc) from the ESU emulator, wind turbine generator emulator and three-phase load system, Figure 3

  13. Electric power generating plant having direct coupled steam and compressed air cycles

    DOE Patents [OSTI]

    Drost, Monte K. (Richland, WA)

    1982-01-01

    An electric power generating plant is provided with a Compressed Air Energy Storage (CAES) system which is directly coupled to the steam cycle of the generating plant. The CAES system is charged by the steam boiler during off peak hours, and drives a separate generator during peak load hours. The steam boiler load is thereby levelized throughout an operating day.

  14. Electric power generating plant having direct-coupled steam and compressed-air cycles

    DOE Patents [OSTI]

    Drost, M.K.

    1981-01-07

    An electric power generating plant is provided with a Compressed Air Energy Storage (CAES) system which is directly coupled to the steam cycle of the generating plant. The CAES system is charged by the steam boiler during off peak hours, and drives a separate generator during peak load hours. The steam boiler load is thereby levelized throughout an operating day.

  15. Load Forecasting of Supermarket Refrigeration

    E-Print Network [OSTI]

    @compute.dtu.dk www.compute.dtu.dk M.Sc.-2013-87 #12;Summary (English) The Danish power production coming from energy system. Observed refrigeration load and local ambient temperature from a Danish su- permarket renewable energy, is increasing, therefore a flexible energy system is needed. In the present Thesis

  16. Scaling the Web Load Testing

    E-Print Network [OSTI]

    Menascé, Daniel A.

    Scaling the Web Load Testing of Web Sites D evelopers typically measure a Web appli- cation on a Web site's IT infrastructure are a function of the site's expect- ed traffic. Ideally, you want, you shouldn't upgrade your Web servers if customers experience most delays in the database server

  17. International agreement report: Assessment study of RELAP-5 MOD-2 Cycle 36. 01 based on the DOEL-2 Steam Generator Tube Rupture incident of June 1979

    SciTech Connect (OSTI)

    Stubbe, E J

    1986-10-01

    This report presents a code assessment study based on a real plant transient that occurred at the DOEL 2 power plant in Belgium on June 25th 1979. DOEL 2 is a two-loop WESTINGHOUSE PWR plant of 392 MWe. A steam generator tube rupture occurred at the end of a heat-up phase which initiated a plant transient which required substantial operator involvement and presented many plant phenomena which are of interest for code assessment. While real plant transients are of special importance for code validation because of the elimination of code scaling uncertainties, they introduce however some uncertainties related to the specifications of the exact initial and boundary conditions which must be reconstructed from available on-line plant recordings and on-line computer diagnostics. Best estimate data have been reconstructed for an assessment study by means of the code RELAP5/MOD2/CYCLE 36.01. Because of inherent uncertainties in the plant data, the assessment work is focussed on phenomena whereby the comparison between plant data and computer data is based more on trends than on absolute values. Such approach is able to uncover basic code weaknesses and strengths which can contribute to a better understanding of the code potential.

  18. Micromechanical Analysis of Geosynthetic-Soil Interaction Under Cyclic Loading

    E-Print Network [OSTI]

    Bhandari, Anil

    2010-05-28

    OF PAPER 85 3.7 CALIBRATION OF GEOTEXTILE AND GEOGRID 87 CHAPTER FOUR 91 4 TRAPDOOR EXPERIMENT AND DEM SIMULATION 91 4.1 EQUIPMENT DESIGN AND TEST PROCEDURE 91 4.2 EXPERIMENTAL RESULTS 94 4.2.1 Unreinforced embankments 94 4.2.2 Reinforced embankments... CHAPTER SIX 160 6 BEHAVIOR OF GEOSYNTHETIC-REINFORCED BASES 160 6.1 GEOTEXTILE-REINFORCED BASE 160 6.1.1 Numerical sample preparation 162 6.1.2 Moving wheel load 164 6.1.3 Contact forces due to moving wheel load 165 6.1.4 Rut depths due to moving...

  19. Distributed generation

    SciTech Connect (OSTI)

    Ness, E.

    1999-09-02

    Distributed generation, locating electricity generators close to the point of consumption, provides some unique benefits to power companies and customers that are not available from centralized electricity generation. Photovoltaic (PV) technology is well suited to distributed applications and can, especially in concert with other distributed resources, provide a very close match to the customer demand for electricity, at a significantly lower cost than the alternatives. In addition to augmenting power from central-station generating plants, incorporating PV systems enables electric utilities to optimize the utilization of existing transmission and distribution.

  20. Local control of reactive power by distributed photovoltaic generators

    SciTech Connect (OSTI)

    Chertkov, Michael; Turitsyn, Konstantin; Sulc, Petr; Backhaus, Scott

    2010-01-01

    High penetration levels of distributed photovoltaic (PV) generation on an electrical distribution circuit may severely degrade power quality due to voltage sags and swells caused by rapidly varying PV generation during cloud transients coupled with the slow response of existing utility compensation and regulation equipment. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g. by minimizing thermal losses. We suggest a local control scheme that dispatches reactive power from each PV inverter based on local instantaneous measurements of the real and reactive components of the consumed power and the real power generated by the PVs. Using one adjustable parameter per circuit, we balance the requirements on power quality and desire to minimize thermal losses. Numerical analysis of two exemplary systems, with comparable total PV generation albeit a different spatial distribution, show how to adjust the optimization parameter depending on the goal. Overall, this local scheme shows excellent performance; it's capable of guaranteeing acceptable power quality and achieving significant saving in thermal losses in various situations even when the renewable generation in excess of the circuit own load, i.e. feeding power back to the higher-level system.

  1. Design Considerations For Blast Loads In Pressure Vessels.

    SciTech Connect (OSTI)

    Rodriguez, E. A. (Edward A.); Nickell, Robert E.; Pepin, J. E. (Jason E.)

    2007-01-01

    Los Alamos National Laboratory (LANL), under the auspices of the U.S. Department of Energy (DOE) and the National Nuclear Security Administration (NNSA), conducts confined detonation experiments utilizing large, spherical, steel pressure vessels to contain the reaction products and hazardous materials from high-explosive (HE) events. Structural design and analysis considerations include: (a) Blast loading phase (i.e., impulsive loading); (b) Dynamic structural response; (c) Fragment (i.e., shrapnel) generation and penetration; (d) Ductile and non-ductile fracture; and (e) Design Criteria to ASME Code Sec. VIII, Div. 3, Impulsively Loaded Vessels. These vessels are designed for one-time-use only, efficiently utilizing the significant plastic energy absorption capability of ductile vessel materials. Alternatively, vessels may be designed for multiple-detonation events, in which case the material response is restricted to elastic or near-elastic range. Code of Federal Regulations, Title 10 Part 50 provides requirements for commercial nuclear reactor licensing; specifically dealing with accidental combustible gases in containment structures that might cause extreme loadings. The design philosophy contained herein may be applied to extreme loading events postulated to occur in nuclear reactor and non-nuclear systems or containments.

  2. A Bio-Inspired Multi-Agent System Framework for Real-Time Load Management in All-Electric Ship Power Systems 

    E-Print Network [OSTI]

    Feng, Xianyong

    2012-07-16

    the impact of pulse loads on the power quality of all-electric ship power systems. Further, the switch status or power set-point of loads in DC zones can be optimally determined to dynamically balance the generation and load while satisfying the operational...

  3. A general formula for non-cohesive bed load sediment transport Benoi^t Camenen), Magnus Larson

    E-Print Network [OSTI]

    US Army Corps of Engineers

    A general formula for non-cohesive bed load sediment transport Benoi^t Camenen), Magnus Larson 2004; accepted 29 October 2004 Abstract A bed load transport formula for non-cohesive sediment, based, oscillatory flows, and combined steady and oscillatory flows. The bed load formula introduced in this study

  4. 1993 Pacific Northwest Loads and Resources Study, Technical Appendix: Volume 2, Book 1, Energy.

    SciTech Connect (OSTI)

    United States. Bonneville Power Administration.

    1993-12-01

    The 1993 Pacific Northwest Loads and Resources Study establishes the Bonneville Power Administration`s (BPA) planning basis for supplying electricity to BPA customers. The Loads and Resources Study is presented in three documents: (1) this technical appendix detailing loads and resources for each major Pacific and Northwest generating utility, (2) a summary of Federal system and Pacific Northwest region loads and resources, and (3) a technical appendix detailing forecasted Pacific Northwest economic trends and loads. This analysis updates the 1992 Pacific Northwest Loads and Resources Study Technical Appendix published in December 1992. This technical appendix provides utility-specific information that BPA uses in its long-range planning. It incorporates the following for each utility (1) Electrical demand firm loads; (2) Generating resources; and (3) Contracts both inside and outside the region. This document should be used in combination with the 1993 Pacific Northwest Loads and Resources Study, published in December 1993, because much of the information in that document is not duplicated here.

  5. PASSIVE DETECTION OF VEHICLE LOADING

    SciTech Connect (OSTI)

    Garrett, A.

    2012-01-03

    The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

  6. Next Generation Radioisotope Generators | Department of Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Generators Next Generation Radioisotope Generators Advanced Stirling Radioisotope Generator (ASRG) - The ASRG is currently being developed as a high-efficiency RPS technology...

  7. SummitView 1.0: a code to automatically generate 3D solid models of surface micro-machining based MEMS designs.

    SciTech Connect (OSTI)

    McBride, Cory L. (Elemental Technologies, American Fort, UT); Yarberry, Victor R.; Schmidt, Rodney Cannon; Meyers, Ray J. (Elemental Technologies, American Fort, UT)

    2006-11-01

    This report describes the SummitView 1.0 computer code developed at Sandia National Laboratories. SummitView is designed to generate a 3D solid model, amenable to visualization and meshing, that represents the end state of a microsystem fabrication process such as the SUMMiT (Sandia Ultra-Planar Multilevel MEMS Technology) V process. Functionally, SummitView performs essentially the same computational task as an earlier code called the 3D Geometry modeler [1]. However, because SummitView is based on 2D instead of 3D data structures and operations, it has significant speed and robustness advantages. As input it requires a definition of both the process itself and the collection of individual 2D masks created by the designer and associated with each of the process steps. The definition of the process is contained in a special process definition file [2] and the 2D masks are contained in MEM format files [3]. The code is written in C++ and consists of a set of classes and routines. The classes represent the geometric data and the SUMMiT V process steps. Classes are provided for the following process steps: Planar Deposition, Planar Etch, Conformal Deposition, Dry Etch, Wet Etch and Release Etch. SummitView is built upon the 2D Boolean library GBL-2D [4], and thus contains all of that library's functionality.

  8. Load Forecast For use in Resource Adequacy

    E-Print Network [OSTI]

    forecast of 4) Calculate Hourly Load Allocation Factor s for each day for 2019 For use in RA analysis as a function ofthe load for electricity in the region as a function of cyclical, weather and economic variables

  9. Residential Load Management Program and Pilot 

    E-Print Network [OSTI]

    Haverlah, D.; Riordon, K.

    1994-01-01

    In 1986 LCRA embarked on residential load management to control peak summer loads. At that time, LCRA was considered a summer peaking utility, and residential air conditioning and water heating systems were selected for control. The program...

  10. Generation of strongly chaotic beats

    E-Print Network [OSTI]

    I. Sliwa; P. Szlachetka; K. Grygiel

    2007-04-25

    The letter proposes a procedure for generation of strongly chaotic beats that have been hardly obtainable hitherto. The beats are generated in a nonlinear optical system governing second-harmonic generation of light. The proposition is based on the concept of an optical coupler but can be easily adopted to other nonlinear systems and Chua's circuits.

  11. NITROGEN LOADINGS FROM SEPTIC SYSTEMS IN THE LOWER FRASER BASIN

    E-Print Network [OSTI]

    Waste Management Zone" (AMZ) as defined in the "Agricultural Inventory of the Lower Fraser Valley Data the data base (acquired from the B.C. Assessment Authority in 1993) in the Ministry of Health report#12;NITROGEN LOADINGS FROM SEPTIC SYSTEMS IN THE LOWER FRASER BASIN DOE FRAP 1997-25 Prepared for

  12. Load Balancing in Wireless Sensor Networks using Kirchhoff's Voltage Law

    E-Print Network [OSTI]

    Toumpis, Stavros

    Load Balancing in Wireless Sensor Networks using Kirchhoff's Voltage Law Stavros Toumpis Electrical balancing in wireless networks with a single class of traffic, focusing our attention on an important example, i.e., Wireless Sensor Networks. The analysis is based on the Wireless Minimum Cost Problem

  13. RELIABILITY BASED DESIGN OF FIXED FOUNDATION WIND TURBINES

    SciTech Connect (OSTI)

    Nichols, R.

    2013-10-14

    Recent analysis of offshore wind turbine foundations using both applicable API and IEC standards show that the total load demand from wind and waves is greatest in wave driven storms. Further, analysis of overturning moment loads (OTM) reveal that impact forces exerted by breaking waves are the largest contributor to OTM in big storms at wind speeds above the operating range of 25 m/s. Currently, no codes or standards for offshore wind power generators have been adopted by the Bureau of Ocean Energy Management Regulation and Enforcement (BOEMRE) for use on the Outer Continental Shelf (OCS). Current design methods based on allowable stress design (ASD) incorporate the uncertainty in the variation of loads transferred to the foundation and geotechnical capacity of the soil and rock to support the loads is incorporated into a factor of safety. Sources of uncertainty include spatial and temporal variation of engineering properties, reliability of property measurements applicability and sufficiency of sampling and testing methods, modeling errors, and variability of estimated load predictions. In ASD these sources of variability are generally given qualitative rather than quantitative consideration. The IEC 61400‐3 design standard for offshore wind turbines is based on ASD methods. Load and resistance factor design (LRFD) methods are being increasingly used in the design of structures. Uncertainties such as those listed above can be included quantitatively into the LRFD process. In LRFD load factors and resistance factors are statistically based. This type of analysis recognizes that there is always some probability of failure and enables the probability of failure to be quantified. This paper presents an integrated approach consisting of field observations and numerical simulation to establish the distribution of loads from breaking waves to support the LRFD of fixed offshore foundations.

  14. System and method employing a minimum distance and a load feature database to identify electric load types of different electric loads

    DOE Patents [OSTI]

    Lu, Bin; Yang, Yi; Sharma, Santosh K; Zambare, Prachi; Madane, Mayura A

    2014-12-23

    A method identifies electric load types of a plurality of different electric loads. The method includes providing a load feature database of a plurality of different electric load types, each of the different electric load types including a first load feature vector having at least four different load features; sensing a voltage signal and a current signal for each of the different electric loads; determining a second load feature vector comprising at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the different electric loads; and identifying by a processor one of the different electric load types by determining a minimum distance of the second load feature vector to the first load feature vector of the different electric load types of the load feature database.

  15. Wind induced torsional loads on structures

    E-Print Network [OSTI]

    Kareem, Ahsan

    -level crosswind loading on a square cross-section building. Reinhold et al.4 instrumented a building model

  16. Plug Load Behavioral Change Demonstration Project

    SciTech Connect (OSTI)

    Metzger, I.; Kandt, A.; VanGeet, O.

    2011-08-01

    This report documents the methods and results of a plug load study of the Environmental Protection Agency's Region 8 Headquarters in Denver, Colorado, conducted by the National Renewable Energy Laboratory. The study quantified the effect of mechanical and behavioral change approaches on plug load energy reduction and identified effective ways to reduce plug load energy. Load reduction approaches included automated energy management systems and behavioral change strategies.

  17. Theory and technology for computational narrative : an approach to generative and interactive narrative with bases in algebraic semiotics and cognitive linguistics

    E-Print Network [OSTI]

    Harrell, Douglas Alan

    2007-01-01

    is that conceptual blending (the generative component) andstructural blending (the media composition component) can bein the blending literature and explicitly designs components

  18. Plutonium Immobilization Can Loading Preliminary Specifications

    SciTech Connect (OSTI)

    Kriikku, E.

    1998-11-25

    This report discusses the Plutonium Immobilization can loading preliminary equipment specifications and includes a process block diagram, process description, equipment list, preliminary equipment specifications, plan and elevation sketches, and some commercial catalogs. This report identifies loading pucks into cans and backfilling cans with helium as the top priority can loading development areas.

  19. Instantaneous Offloading of Transient Web Server Load

    E-Print Network [OSTI]

    Instantaneous Offloading of Transient Web Server Load Vsevolod V. Panteleenko and Vincent W. Freeh A modern web-hosting site is designed to handle load that is sometimes an order of magnitude greater than and performance study of the web booster architecture, which reduces web server load during peak periods. A web

  20. An Analysis of Dual Zone Loading for Shipping Spent Nuclear Fuel

    SciTech Connect (OSTI)

    Allen, William Christopher; Yim, Man-Sung

    2007-07-01

    The bumps current fuel assembly designs can achieve exceeds the fuel assembly burnups the current fleet of shipping casks can ship. One method of handling this situation which has been proposed is regionalized loading. This concept involves administratively separating the fuel basket of a shipping cask into two or more regions and loading fuel with different burnup, cooling times and enrichments into these regions. To evaluate how regionalized loading patterns might affect shipping spent nuclear fuel in comparison to uniform loading, a test case study was performed using fuel assemblies discharged from an actual nuclear plant and a shipping cask licensed by the NRC. Using the same fuel assemblies and shipping cask, results were obtained assuming a uniform loading pattern and compared to the results obtained assuming a dual zone loading pattern. Source terms for the analysis were generated using SAS2 and the dose levels were calculated using MCNPS. The analysis showed that the dual zone loading reduced the amount of time required to ship the given quantity of fuel by roughly thirty percent compared to the uniform loading. The average dose rate to the transportation workers and the public due to the implementation of dual zone loading increased. Implications of these increases are discussed. (authors)

  1. Explicit spatial scattering for load balancing in conservatively synchronized parallel discrete-event simulations

    SciTech Connect (OSTI)

    Thulasidasan, Sunil [Los Alamos National Laboratory; Kasiviswanathan, Shiva [Los Alamos National Laboratory; Eidenbenz, Stephan [Los Alamos National Laboratory; Romero, Philip [Los Alamos National Laboratory

    2010-01-01

    We re-examine the problem of load balancing in conservatively synchronized parallel, discrete-event simulations executed on high-performance computing clusters, focusing on simulations where computational and messaging load tend to be spatially clustered. Such domains are frequently characterized by the presence of geographic 'hot-spots' - regions that generate significantly more simulation events than others. Examples of such domains include simulation of urban regions, transportation networks and networks where interaction between entities is often constrained by physical proximity. Noting that in conservatively synchronized parallel simulations, the speed of execution of the simulation is determined by the slowest (i.e most heavily loaded) simulation process, we study different partitioning strategies in achieving equitable processor-load distribution in domains with spatially clustered load. In particular, we study the effectiveness of partitioning via spatial scattering to achieve optimal load balance. In this partitioning technique, nearby entities are explicitly assigned to different processors, thereby scattering the load across the cluster. This is motivated by two observations, namely, (i) since load is spatially clustered, spatial scattering should, intuitively, spread the load across the compute cluster, and (ii) in parallel simulations, equitable distribution of CPU load is a greater determinant of execution speed than message passing overhead. Through large-scale simulation experiments - both of abstracted and real simulation models - we observe that scatter partitioning, even with its greatly increased messaging overhead, significantly outperforms more conventional spatial partitioning techniques that seek to reduce messaging overhead. Further, even if hot-spots change over the course of the simulation, if the underlying feature of spatial clustering is retained, load continues to be balanced with spatial scattering leading us to the observation that spatial scattering can often obviate the need for dynamic load balancing.

  2. Abstract--Power efficiency during heavy-and light-loading conditions in wireless portable applications is critical for

    E-Print Network [OSTI]

    Rincon-Mora, Gabriel A.

    and quiescent current flow during light loading conditions and (2) an adaptive PA bias-current generator1 Abstract-- Power efficiency during heavy- and light-loading conditions in wireless portable efficiency is improved with a 0.5-µm CMOS dynamically adaptive, dual-mode buck- boost power supply and bias

  3. Abstract--We present new approaches for 5-minute ahead electricity load forecasting. They were evaluated on data from

    E-Print Network [OSTI]

    Koprinska, Irena

    .e. the cheapest generator is allocated first, the second cheapest next and so on until the electricity demandAbstract--We present new approaches for 5-minute ahead electricity load forecasting. They were evaluated on data from the Australian electricity market operator for 2006-2008. After examining the load

  4. High loading uranium fuel plate

    DOE Patents [OSTI]

    Wiencek, Thomas C. (Bolingbrook, IL); Domagala, Robert F. (Indian Head Park, IL); Thresh, Henry R. (Palos Heights, IL)

    1990-01-01

    Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pair of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat having a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process.

  5. Automated fuel pin loading system

    DOE Patents [OSTI]

    Christiansen, David W. (Kennewick, WA); Brown, William F. (West Richland, WA); Steffen, Jim M. (Richland, WA)

    1985-01-01

    An automated loading system for nuclear reactor fuel elements utilizes a gravity feed conveyor which permits individual fuel pins to roll along a constrained path perpendicular to their respective lengths. The individual lengths of fuel cladding are directed onto movable transports, where they are aligned coaxially with the axes of associated handling equipment at appropriate production stations. Each fuel pin can be reciprocated axially and/or rotated about its axis as required during handling steps. The fuel pins are inserted as a batch prior to welding of end caps by one of two disclosed welding systems.

  6. Analysis and Synthesis of Load Forecasting Data for Renewable Integration Studies: Preprint

    SciTech Connect (OSTI)

    Steckler, N.; Florita, A.; Zhang, J.; Hodge, B. M.

    2013-11-01

    As renewable energy constitutes greater portions of the generation fleet, the importance of modeling uncertainty as part of integration studies also increases. In pursuit of optimal system operations, it is important to capture not only the definitive behavior of power plants, but also the risks associated with systemwide interactions. This research examines the dependence of load forecast errors on external predictor variables such as temperature, day type, and time of day. The analysis was utilized to create statistically relevant instances of sequential load forecasts with only a time series of historic, measured load available. The creation of such load forecasts relies on Bayesian techniques for informing and updating the model, thus providing a basis for networked and adaptive load forecast models in future operational applications.

  7. INCREMENTAL COOLING LOAD DETERMINATION FOR PASSIVE DIRECT GAIN HEATING SYSTEMS

    E-Print Network [OSTI]

    Sullivan, Paul W.

    2013-01-01

    May 27-30, 1981 INCREMENTAL COOLING LOAD DETERMINATION FOR12048 May 1981 INCREMENTAL COOLING LOAD DETERMINATION FORfor increases in the building cooling load resulting from

  8. Investigation of residential central air conditioning load shapes in NEMS

    E-Print Network [OSTI]

    Hamachi LaCommare, Kristina; Marnay, Chris; Gumerman, Etan; Chan, Peter; Rosenquist, Greg; Osborn, Julie

    2002-01-01

    of Residential Central Air Conditioning Load Shapes in NEMSof Residential Central Air Conditioning Load Shapes in NEMSof Residential Central Air Conditioning Load Shapes in NEMS

  9. ELECTRICAL LOAD MANAGEMENT FOR THE CALIFORNIA WATER SYSTEM

    E-Print Network [OSTI]

    Krieg, B.

    2010-01-01

    Development Commission. Load Management in California. Staffon the Challenge of Load Management, Conservation Paper No.for Electric Utility Load Management. New York, New York:

  10. RESEARCH ARTICLE An experimental study of flow fields and wind loads on gable-roof

    E-Print Network [OSTI]

    Hu, Hui

    RESEARCH ARTICLE An experimental study of flow fields and wind loads on gable-roof building models the resultant wind loads acting on low-rise, gable-roof buildings induced by violent microburst-like winds State University. Two gable-roof building models with the same base plan and mean roof height

  11. LOAD PROFILING IN DISTRIBUTED REALTIME SYSTEMS \\Lambda ``One Size Doesn't Fit All''

    E-Print Network [OSTI]

    . Using load profiling, the system attempts to distribute the load amongst its nodes so as to maximize the chances of finding a node that would satisfy the computational needs of incoming real­time tasks engineering based on a solid, analytical foundation for real­time resource management. Examples include

  12. 168 / JOURNAL OF STRUCTURAL ENGINEERING / FEBRUARY 2001 GUST LOADING FACTOR: NEW MODEL

    E-Print Network [OSTI]

    Kareem, Ahsan

    )]. It should be pointed out that the Australian Standard (1989) and the ACI standard (1988) use the GLF and standards around the world. In this scheme, the equivalent static wind loading used for design is equal and standards. Currently, the ESWL in building codes is estimated based on the ``gust load- ing factor'' (GLF

  13. Reliability analysis and prediction of mixed mode load using Markov Chain Model

    SciTech Connect (OSTI)

    Nikabdullah, N.; Singh, S. S. K.; Alebrahim, R.; Azizi, M. A.; K, Elwaleed A.; Noorani, M. S. M.

    2014-06-19

    The aim of this paper is to present the reliability analysis and prediction of mixed mode loading by using a simple two state Markov Chain Model for an automotive crankshaft. The reliability analysis and prediction for any automotive component or structure is important for analyzing and measuring the failure to increase the design life, eliminate or reduce the likelihood of failures and safety risk. The mechanical failures of the crankshaft are due of high bending and torsion stress concentration from high cycle and low rotating bending and torsional stress. The Markov Chain was used to model the two states based on the probability of failure due to bending and torsion stress. In most investigations it revealed that bending stress is much serve than torsional stress, therefore the probability criteria for the bending state would be higher compared to the torsion state. A statistical comparison between the developed Markov Chain Model and field data was done to observe the percentage of error. The reliability analysis and prediction was derived and illustrated from the Markov Chain Model were shown in the Weibull probability and cumulative distribution function, hazard rate and reliability curve and the bathtub curve. It can be concluded that Markov Chain Model has the ability to generate near similar data with minimal percentage of error and for a practical application; the proposed model provides a good accuracy in determining the reliability for the crankshaft under mixed mode loading.

  14. Large Hybrid Energy Systems for Making Low CO2 Load-Following Power and Synthetic Fuel

    SciTech Connect (OSTI)

    Robert S. Cherry; Richard D. Boardman; Steven Aumeier

    2012-02-01

    Hybrid energy systems using nuclear heat sources can economically produce load-following electrical power by exploiting the surplus generation capacity available at night or seasonally to make synthetic fuel. Vehicle fuel is the only current energy use large enough to absorb all the energy capacity that might be diverted from the power industry, and its ease of storage obviates problems with discontinuous synfuel production. The potential benefits and challenges of synfuels integration are illustrated by the production of methanol from natural gas (as a source of carbon) using steam from a light water nuclear power reactor which is assumed to be available in accord with a year's worth of power demand data. Methanol's synthesis process is easily adapted to using 300 C heat from a light water reactor and this simple compound can be further processed into gasoline, biodiesel, or dimethyl ether, fuels which can be used with the current vehicle fleet. A supplemental feed to the methanol process of natural gas (for energy) allows operation at constant full rate when the nuclear heat is being used to produce electrical power. The higher capital costs of such a system are offset by a lower cost of heat and power production from a large base load type of plant and by reduced costs associated with much lower CO2 emissions. Other less tangible economic benefits of this and similar hybrid systems include better use of natural resource for fuels and greater energy services security from the domestic production of vehicle fuel.

  15. Assessment of Industrial Load for Demand Response across Western Interconnect

    SciTech Connect (OSTI)

    Alkadi, Nasr E; Starke, Michael R; Ma, Ookie

    2013-11-01

    Demand response (DR) has the ability to both increase power grid reliability and potentially reduce operating system costs. Understanding the role of demand response in grid modeling has been difficult due to complex nature of the load characteristics compared to the modeled generation and the variation in load types. This is particularly true of industrial loads, where hundreds of different industries exist with varying availability for demand response. We present a framework considering industrial loads for the development of availability profiles that can provide more regional understanding and can be inserted into analysis software for further study. The developed framework utilizes a number of different informational resources, algorithms, and real-world measurements to perform a bottom-up approach in the development of a new database with representation of the potential demand response resource in the industrial sector across the U.S. This tool houses statistical values of energy and demand response (DR) potential by industrial plant and geospatially locates the information for aggregation for different territories without proprietary information. This report will discuss this framework and the analyzed quantities of demand response for Western Interconnect (WI) in support of evaluation of the cost production modeling with power grid modeling efforts of demand response.

  16. Performance of the OVP/UVP and OFP/UFP method with voltage and frequency dependent loads

    E-Print Network [OSTI]

    Kirtley, James L., Jr.

    In previous literature, constant RLC loads were assumed to impose, on the islanding detection method, the hardest detectable case. For this reason, distributed-generation (DG) islanding studies are usually analyzed and ...

  17. Estimation of Seismic Load Demand for a Wind Turbine in the Time Domain: Preprint

    SciTech Connect (OSTI)

    Prowell, I.; Elgamal, A.; Uang, C.; Jonkman, J.

    2010-03-01

    Turbines installed in seismically active regions such as the Pacific Rim or the Mediterranean must consider loads induced by base shaking from an earthquake. To account for this earthquake risk, current International Electrotechnical Commission (IEC) certification requirements provide a simplified method for calculating seismic loads which is intended to be conservative. Through the addition of capabilities, it is now possible to simulate earthquake loading of a wind turbine in conjunction other load sources such as wind and control system behavior using the FAST code. This paper presents a comparison of three earthquake loading scenarios of the National Renewable Energy Laboratory (NREL) offshore 5-MW baseline wind turbine: idling; continued operation through an earthquake; and an emergency shutdown initiated by an earthquake. Using a set of 22 earthquake records, simulations are conducted for each load case. A summary of the resulting tower moment demand is presented to assess the influence of operational state on the resulting structural demand.

  18. Decision-Support Software for Grid Operators: Transmission Topology Control for Infrastructure Resilience to the Integration of Renewable Generation

    SciTech Connect (OSTI)

    2012-03-16

    GENI Project: The CRA team is developing control technology to help grid operators more actively manage power flows and integrate renewables by optimally turning on and off entire power lines in coordination with traditional control of generation and load resources. The control technology being developed would provide grid operators with tools to help manage transmission congestion by identifying the facilities whose on/off status must change to lower generation costs, increase utilization of renewable resources and improve system reliability. The technology is based on fast optimization algorithms for the near to real-time change in the on/off status of transmission facilities and their software implementation.

  19. Analysis of the cryogenic system behavior for pulsed heat load in EAST

    SciTech Connect (OSTI)

    Hu, L. B.; Zhuang, M.; Zhou, Z. W.; Xia, G. H. [Cryogenic Engineering Division, Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Shushanhu Road 350, Hefei, Anhui 230031 (China)

    2014-01-29

    EAST is the first full superconducting fusion device. The plasma is confined by the magnetic fields generated from a large set of superconducting magnets which are made of cable in-conduit conductor (CICC). In operation, these magnets suffer heat loads from thermal and nuclear radiation from the surrounding components and plasma as well as the eddy currents and the AC losses generated within the magnets, together with the heat conduction through supports and the resistive heat generated at the current lead transiting to room temperature. The cryogenic system of our EAST consists of a 2kW/4K helium refrigerator and a distribution system for the cooling of poloidal field (PF) and toroidal field (TF) coils, structures, thermal shields, buslines and current leads. Pulsed heat load is the main difference between the cryogenic system of a full superconducting Tokamak system and other large scale cryogenic systems. The cryogenic system operates in a pulsed heat loads mode requiring the helium refrigerator to remove periodically large heat loads in time. At the same time, the cryogenic system parameters such as helium cooling superconducting magnets, helium refrigerator and helium distribution system are changing. In this paper, the variation range of the parameters of superconducting magnets and refrigerator has been analyzed in the typical plasma discharge mode. The control scheme for the pulsed loads characteristics of the cryogenic system has been proposed, the implementation of which helps to smooth the pulse loads and to improve the stability of the operation of the cryogenic system.

  20. Probabilistic Approach to Quantifying the Contribution of Variable Generation and Transmission to System Reliability: Preprint

    SciTech Connect (OSTI)

    Ibanez, E.; Milligan, M.

    2012-09-01

    The increasing electrical load served by variable generation (VG), such as wind and solar energy, in the United States and many other countries has stimulated an interesting line of research to better quantify the capacity value of these resources. Methods applied traditionally to thermal units based on their average outage rates do not apply to VG because of their uncertain and non-dispatchable nature. The North American Electric Reliability Corporation's Integration of Variable Generation Task Force recently released a report that highlighted the need to develop and benchmark underlying loss-of-load expectation and related metrics that reasonably and fairly calculate the contribution to planning reserves, or capacity value, of solar and wind power. As the fraction of generation coming from VG becomes more significant, their estimated capacity value will have a larger impact on system planning. In this paper, we provide a method to include VG in traditional probabilistic-based adequacy methods. This method has been implemented in the Renewable Energy Probabilistic Resource Assessment tool developed at the National Renewable Energy Laboratory. Through an example based on the U.S. Western Interconnection, this method is applied to assess the effect that transmission can have on resource adequacy. We also analyze the interactions between available transmission and capacity value for VG.

  1. Next Generation Calibration Models with Dimensional Modeling...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Decision Tree Based Control Model-Based Transient Calibration Optimization for Next Generation Diesel Engines An Accelerated Aging Method for Diesel Exhaust Aftertreatment Systems...

  2. Developing and Implementing the Foundation for a Renewable Energy-Based "Distribution Generation Micro-grid": A California Energy Commission Public Interest Energy Research Co-Funded Program 

    E-Print Network [OSTI]

    Lilly, P.; Sebold, F. D.; Carpenter, M.; Kitto, W.

    2002-01-01

    The California Energy Commission has been implementing its Public Interest Energy Research (PIER) and Renewable Energy Programs since early 1998. In the last two years, the demand for renewable distributed generation systems has increased rapidly...

  3. The Next Generation Nuclear Plant Graphite Creep Experiment Irradiation in the Advanced Test Reactor

    SciTech Connect (OSTI)

    Blaine Grover

    2010-10-01

    The United States Department of Energy’s Next Generation Nuclear Plant (NGNP) Program will be irradiating six gas reactor graphite creep experiments in the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL). The ATR has a long history of irradiation testing in support of reactor development and the INL has been designated as the United States Department of Energy’s lead laboratory for nuclear energy development. The ATR is one of the world’s premiere test reactors for performing long term, high flux, and/or large volume irradiation test programs. These graphite irradiations are being accomplished to support development of the next generation reactors in the United States. The graphite experiments will be irradiated over the next six to eight years to support development of a graphite irradiation performance data base on the new nuclear grade graphites now available for use in high temperature gas reactors. The goals of the irradiation experiments are to obtain irradiation performance data, including irradiation creep, at different temperatures and loading conditions to support design of the Next Generation Nuclear Plant (NGNP) Very High Temperature Gas Reactor, as well as other future gas reactors. The experiments will each consist of a single capsule that will contain six stacks of graphite specimens, with half of the graphite specimens in each stack under a compressive load, while the other half of the specimens will not be subjected to a compressive load during irradiation. The six stacks will have differing compressive loads applied to the top half of each pair of specimen stacks, while a seventh stack will not have a compressive load. The specimens will be irradiated in an inert sweep gas atmosphere with on-line temperature and compressive load monitoring and control. There will also be the capability of sampling the sweep gas effluent to determine if any oxidation or off-gassing of the specimens occurs during initial start-up of the experiment. The first experiment was inserted in the ATR in August 2009 and started its irradiation in September 2009. It is anticipated to complete its irradiation in early calendar 2011. This paper will discuss the design of the experiment including the test train and the temperature and compressive load monitoring, control, and the irradiation experience to date.

  4. Preliminary Evaluation of Load Management for Electricity End Users 

    E-Print Network [OSTI]

    Collier, S. E.

    1984-01-01

    The planning, design and implementation of load management is complex and expensive. The results of a load management program are subject to numerous uncertainties related to load characteristics, power cost savings, load management costs...

  5. Rare-Earth-Free Nanostructure Magnets: Rare-Earth-Free Permanent Magnets for Electric Vehicle Motors and Wind Turbine Generators: Hexagonal Symmetry Based Materials Systems Mn-Bi and M-type Hexaferrite

    SciTech Connect (OSTI)

    2012-01-01

    REACT Project: The University of Alabama is developing new iron- and manganese-based composite materials for use in the electric motors of EVs and renewable power generators that will demonstrate magnetic properties superior to today’s best rare-earth-based magnets. Rare earths are difficult and expensive to refine. EVs and renewable power generators typically use rare earths to make their electric motors smaller and more powerful. The University of Alabama has the potential to improve upon the performance of current state-of-the-art rare-earth-based magnets using low-cost and more abundant materials such as manganese and iron. The ultimate goal of this project is to demonstrate improved performance in a full-size prototype magnet at reduced cost.

  6. Plasma plume MHD power generator and method

    DOE Patents [OSTI]

    Hammer, J.H.

    1993-08-10

    A method is described of generating power at a situs exposed to the solar wind which comprises creating at separate sources at the situs discrete plasma plumes extending in opposed directions, providing electrical communication between the plumes at their source and interposing a desired electrical load in the said electrical communication between the plumes.

  7. Dynamic Load Balancing on Single- and Multi-GPU Systems

    SciTech Connect (OSTI)

    Chen, Long; Villa, Oreste; Krishnamoorthy, Sriram; Gao, Guang R.

    2010-04-19

    The computational power provided by many-core graphics processing units (GPUs) has been exploited in many applications. The programming techniques supported and employed on these GPUs are not sufficient to address problems exhibiting irregular, and unbalanced workload. The problem is exacerbated when trying to effectively exploit multiple GPUs, which are commonly available in many modern systems. In this paper, we propose a task-based dynamic load-balancing solution for single- and multi-GPU systems. The solution allows load balancing at a finer granularity than what is supported in existing APIs such as NVIDIA’s CUDA. We evaluate our approach using both micro-benchmarks and a molecular dynamics application that exhibits significant load imbalance. Experimental results with a single-GPU configuration show that our fine-grained task solution can utilize the hardware more efficiently than the CUDA scheduler for unbalanced workload. On multi-GPU systems, our solution achieves near-linear speedup, load balance, and significant performance improvement over techniques based on standard CUDA APIs.

  8. Load Reduction, Demand Response and Energy Efficient Technologies and Strategies

    SciTech Connect (OSTI)

    Boyd, Paul A.; Parker, Graham B.; Hatley, Darrel D.

    2008-11-19

    The Department of Energy’s (DOE’s) Pacific Northwest National Laboratory (PNNL) was tasked by the DOE Office of Electricity (OE) to recommend load reduction and grid integration strategies, and identify additional demand response (energy efficiency/conservation opportunities) and strategies at the Forest City Housing (FCH) redevelopment at Pearl Harbor and the Marine Corps Base Hawaii (MCBH) at Kaneohe Bay. The goal was to provide FCH staff a path forward to manage their electricity load and thus reduce costs at these FCH family housing developments. The initial focus of the work was at the MCBH given the MCBH has a demand-ratchet tariff, relatively high demand (~18 MW) and a commensurate high blended electricity rate (26 cents/kWh). The peak demand for MCBH occurs in July-August. And, on average, family housing at MCBH contributes ~36% to the MCBH total energy consumption. Thus, a significant load reduction in family housing can have a considerable impact on the overall site load. Based on a site visit to the MCBH and meetings with MCBH installation, FCH, and Hawaiian Electric Company (HECO) staff, recommended actions (including a "smart grid" recommendation) that can be undertaken by FCH to manage and reduce peak-demand in family housing are made. Recommendations are also made to reduce overall energy consumption, and thus reduce demand in FCH family housing.

  9. Commercial Building Loads Providing Ancillary Services in PJM

    SciTech Connect (OSTI)

    MacDonald, Jason; Kiliccote, Sila; Boch, Jim; Chen, Jonathan; Nawy, Robert

    2014-06-27

    The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

  10. Load research manual. Volume 2. Fundamentals of implementing load research procedures

    SciTech Connect (OSTI)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  11. Did English Generators Play Cournot? Capacity Withholding in the Electricity Pool

    E-Print Network [OSTI]

    Green, Richard J.

    2004-06-16

    The electricity industry in England and Wales was restructured in March 1990. The integrated Central Electricity Generating Board was divided into three generating companies and the National Grid Company (NGC), responsible for transmission. NGC also operated... published the load factors of its stations, while the MMC published information on the load factors of National Power and PowerGen’s coal-fired stations in its 1996 reports into their merger proposals. NGC provided load-duration curves, showing...

  12. High voltage load resistor array

    DOE Patents [OSTI]

    Lehmann, Monty Ray (Smithfield, VA)

    2005-01-18

    A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

  13. Technetium-99m generator system

    DOE Patents [OSTI]

    Mirzadeh, S.; Knapp, F.F. Jr.; Collins, E.D.

    1998-06-30

    A {sup 99}Mo/{sup 99m}Tc generator system includes a sorbent column loaded with a composition containing {sup 99}Mo. The sorbent column has an effluent end in fluid communication with an anion-exchange column for concentrating {sup 99m}Tc eluted from the sorbent column. A method of preparing a concentrated solution of {sup 99m}Tc includes the general steps of: (a) providing a sorbent column loaded with a composition containing {sup 99}Mo, the sorbent column having an effluent end in fluid communication with an anion-exchange column; (b) eluting the sorbent column with a salt solution to elute {sup 99m}Tc from the sorbent and to trap and concentrate the eluted {sup 99m}Tc on the ion-exchange column; and (c) eluting the concentrated {sup 99m}Tc from the ion-exchange column with a solution comprising a reductive complexing agent. 1 fig.

  14. Technical Assistance to ISO's and Grid Operators For Loads Providing...

    Office of Environmental Management (EM)

    & Publications Loads Providing Ancillary Services: Review of International Experience Demand Response and Energy Storage Integration Study - Past Workshops Load Participation...

  15. Photon generator

    DOE Patents [OSTI]

    Srinivasan-Rao, Triveni (Shoreham, NY)

    2002-01-01

    A photon generator includes an electron gun for emitting an electron beam, a laser for emitting a laser beam, and an interaction ring wherein the laser beam repetitively collides with the electron beam for emitting a high energy photon beam therefrom in the exemplary form of x-rays. The interaction ring is a closed loop, sized and configured for circulating the electron beam with a period substantially equal to the period of the laser beam pulses for effecting repetitive collisions.

  16. Electric generator

    DOE Patents [OSTI]

    Foster, Jr., John S. (Pleasanton, CA); Wilson, James R. (Livermore, CA); McDonald, Jr., Charles A. (Danville, CA)

    1983-01-01

    1. In an electrical energy generator, the combination comprising a first elongated annular electrical current conductor having at least one bare surface extending longitudinally and facing radially inwards therein, a second elongated annular electrical current conductor disposed coaxially within said first conductor and having an outer bare surface area extending longitudinally and facing said bare surface of said first conductor, the contiguous coaxial areas of said first and second conductors defining an inductive element, means for applying an electrical current to at least one of said conductors for generating a magnetic field encompassing said inductive element, and explosive charge means disposed concentrically with respect to said conductors including at least the area of said inductive element, said explosive charge means including means disposed to initiate an explosive wave front in said explosive advancing longitudinally along said inductive element, said wave front being effective to progressively deform at least one of said conductors to bring said bare surfaces thereof into electrically conductive contact to progressively reduce the inductance of the inductive element defined by said conductors and transferring explosive energy to said magnetic field effective to generate an electrical potential between undeformed portions of said conductors ahead of said explosive wave front.

  17. FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH

    E-Print Network [OSTI]

    Lesieutre, Bernard

    2013-01-01

    of a synchronous generator,” IEEE Transactions on Powercomponents, such as synchronous generators, are well components, such as synchronous generators, are well

  18. NEUTRON WALL LOADING OF TOKAMAK REACTORS

    E-Print Network [OSTI]

    California at Los Angeles, University of

    GA­A23223 NEUTRON WALL LOADING OF TOKAMAK REACTORS by C.P.C. WONG OCTOBER 1999 #12;DISCLAIMER Government or any agency thereof. #12;GA­A23223 NEUTRON WALL LOADING OF TOKAMAK REACTORS by C.P.C. WONG by General Atomics IR&D Funds GA PROJECT 4437 OCTOBER 1999 #12;C.P.C. WONG NEUTRON WALL LOADING OF TOKAMAK

  19. Measured Peak Equipment Loads in Laboratories

    SciTech Connect (OSTI)

    Mathew, Paul A.

    2007-09-12

    This technical bulletin documents measured peak equipment load data from 39 laboratory spaces in nine buildings across five institutions. The purpose of these measurements was to obtain data on the actual peak loads in laboratories, which can be used to rightsize the design of HVAC systems in new laboratories. While any given laboratory may have unique loads and other design considerations, these results may be used as a 'sanity check' for design assumptions.

  20. Real power regulation for the utility power grid via responsive loads

    DOE Patents [OSTI]

    McIntyre, Timothy J [Knoxville, TN; Kirby, Brendan J [Knoxville, TN; Kisner, Roger A

    2009-05-19

    A system for dynamically managing an electrical power system that determines measures of performance and control criteria for the electric power system, collects at least one automatic generation control (AGC) input parameter to at least one AGC module and at least one automatic load control (ALC) input parameter to at least one ALC module, calculates AGC control signals and loads as resources (LAR) control signals in response to said measures of performance and control criteria, propagates AGC control signals to power generating units in response to control logic in AGC modules, and propagates LAR control signals to at least one LAR in response to control logic in ALC modules.