National Library of Energy BETA

Sample records for backup generators bugs

  1. Backup Generators (BUGS): The Next Smart Grid Peak Resource?...

    Open Energy Info (EERE)

    URI: cleanenergysolutions.orgcontentbackup-generators-bugs-next-smart-gri Language: English Policies: "Deployment Programs,Financial Incentives,Regulations" is not in...

  2. Using Backup Generators: Choosing the Right Backup Generator...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Homeowners Using Backup Generators: Choosing the Right Backup Generator - Homeowners Using Backup Generators: Choosing the Right Backup Generator - Homeowners Determine the amount ...

  3. Using Backup Generators: Alternative Backup Power Options

    Office of Energy Efficiency and Renewable Energy (EERE)

    Using Backup Generators: In preparing for emergencies, in addition to electric generators powered by fuel, homeowners and business owners may consider alternative backup power options

  4. Using Backup Generators: Choosing the Right Backup Generator - Homeowners |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Homeowners Using Backup Generators: Choosing the Right Backup Generator - Homeowners Using Backup Generators: Choosing the Right Backup Generator - Homeowners Determine the amount of power you will need-How much power do you need to operate equipment and appliances connected to the generator? Portable generators made for household use can provide temporary power to a small number of selected appliances or lights. For example, light bulb wattage indicates the power needed

  5. Using Backup Generators: Choosing the Right Backup Generator - Business

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Owners | Department of Energy Business Owners Using Backup Generators: Choosing the Right Backup Generator - Business Owners Using Backup Generators: Choosing the Right Backup Generator - Business Owners Identify essential systems and equipment-What do you need to keep your business operating? These may include heating, ventilation, and air conditioning systems; industrial equipment and major appliances, such as refrigerators and freezers; lights (interior and exterior), computers, and other

  6. Using Backup Generators | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Generators Using Backup Generators Using Backup Generators Power outages are commonplace during disasters, and they may last for several days. You can reduce losses and speed the recovery process by installing an emergency generator. Portable generators made for household use can provide temporary power to a small number of selected appliances or lights, and commercial generators can help prevent the interruption of operations at businesses and critical infrastructure facilities like hospitals,

  7. Using Backup Generators: Alternative Backup Power Options | Department...

    Energy Savers [EERE]

    As the solar panels generate energy during the day, any ... used by the public than solar-powered systems because ... This often makes permitting and installing the systems ...

  8. The California Demonstration Program for Control of PM from Diesel Backup

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Generators (BUGs) | Department of Energy (BUGs) The California Demonstration Program for Control of PM from Diesel Backup Generators (BUGs) 2003 DEER Conference Presentation: University of California at Riverside 2003_deer_miller.pdf (1.26 MB) More Documents & Publications The California Demonstration Program for Control of PM from Diesel Backup Generators = Measuring "Real World" Heavy-Duty Diesel Emissions with a Mobile Lab Emissions from In-Use NG, Propane, and Diesel Fueled

  9. Microsoft Word - BUGS_The Next Smart Grid Peak Resource Final 4_19.docx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    April 15, 2010 DOE/NETL-2010/1406 Backup Generators (BUGS): The Next Smart Grid Peak Resource Backup Generators (BUGS): The Next Smart Grid Peak Resource v1.0 ii DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness

  10. Backup power working group best practices handbook for maintenance and operation of engine generators, Volume 1. Revision 1

    SciTech Connect (OSTI)

    Gross, R.; Padgett, A.B.; Burrows, K.P.; Fairchild, P.N.; Lam, T.; Janes, J.

    1997-06-01

    This handbook is divided into the four chapters. Chapter one covers the design, procurement, storage, handling and testing of diesel fuel oil to be used in DOE backup power supplies. Chapter two discusses the selection of automatic transfer switches to be used in DOE backup power supplies. Chapter three is about low voltage open frame air circuit breaker operation, testing, and maintenance for DOE backup power supplies. And chapter four covers installation, design, and maintenance of engine cooling water and jacket water systems.

  11. PGI Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    PGI PGI Bug Reports PGI Bug Reports Internal compiler error for function pointer with identically named arguments June 9, 2015 by Scott French, NERSC USG Status: Bug 21435...

  12. Backup Power Cost of Ownership Analysis and Incumbent Technology...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    power and presents the estimated annualized cost of ownership for fuel cell backup power systems compared with the incumbent technologies of battery and diesel generator systems. ...

  13. Backup Power Cost of Ownership Analysis and Incumbent Technology Comparison

    SciTech Connect (OSTI)

    Kurtz, J.; Saur, G.; Sprik, S.; Ainscough, C.

    2014-09-01

    This cost of ownership analysis identifies the factors impacting the value proposition for fuel cell backup power and presents the estimated annualized cost of ownership for fuel cell backup power systems compared with the incumbent technologies of battery and diesel generator systems. The analysis compares three different backup power technologies (diesel, battery, and fuel cell) operating in similar circumstances in four run time scenarios (8, 52, 72, and 176 hours).

  14. DOE Backup Power Working Group Best Practices Handbook for Maintenance and Operation of Engine Generators, Volume II

    SciTech Connect (OSTI)

    Gross, R.E.

    1998-10-30

    The lubricating oil system provides a means to introduce a lubricant in the form of a film to reduce friction and wear between surfaces that bear against each other as they move.1 The oil film which is established also cools the parts by carrying generated heat away from hot surfaces, cleans and carries dirt or metal wear particles to the filter media, and helps seal the piston to the cylinder during combustion. Most systems are pressure lubricated and distribute oil under pressure to bearings, gears, and power assemblies. Lubricating oil usually reaches main, connecting rod, and camshaft bearings through drilled passages in the cylinder block and crankshaft or through piping and common manifolds.Many parts rely on oil for cooling, so if the lube oil system fails to perform its function the engine will overheat. Metal to metal surfaces not separated by a thin film of oil rapidly build up frictional heat. As the metals reach their melting point, they tend to weld together in spots or streaks. Lube oil system failures can cause significant damage to an engine in a short period of time. Proper maintenance and operation of the lubricating oil system is essential if your engine is to accomplish its mission.

  15. PGI Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    pgipgi-bug-reportsrss Internal compiler error for function pointer with identically named arguments http:www.nersc.govuserssoftwarecompilerspgipgi-bug-reports...

  16. CAF Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    caf-coarray-fortrancaf-bug-reportsrss There are currently no significant reported user bugs with CAF. http:www.nersc.govuserssoftwarecompilerscaf-coarray-fortran...

  17. Using Backup Generators: Choosing the Right Backup Generator...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of the facility, or with an automated or manual transfer switch that sheds enough of the ... Specifically check the requirements for the use of automatic or manual transfer switches ...

  18. Backup Power Cost of Ownership Analysis and Incumbent Technology Comparison

    Office of Energy Efficiency and Renewable Energy (EERE)

    This cost of ownership analysis identifies the factors impacting the value proposition for fuel cell backup power and presents the estimated annualized cost of ownership for fuel cell backup power systems compared with the incumbent technologies of battery and diesel generator systems.

  19. GNU Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    GNU » GNU Bug Reports GNU Bug Reports There are currently no significant reported user bugs with the GNU compilers. November 18, 2013 by Mike Stewart, NERSC USG. Status: No current NERSC user bugs. Read the full post Subscribe via RSS Subscribe Browse by Date November 2013 Last edited: 2016-04-29 11:34:27

  20. Cray Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Cray » Cray Bug Reports Cray Bug Reports Cray C/C++ predefined _RELEASE macro returns wrong value [updated] November 18, 2013 by Mike Stewart, NERSC USG Status: Reported to Cray as bug 797442, became documentation bug 805340. Read the full post Subscribe via RSS Subscribe Browse by Date November 2013 Last edited: 2016-04-29 11:34:26

  1. CAF Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    » CAF Bug Reports CAF Bug Reports There are currently no significant reported user bugs with CAF. November 18, 2013 No reported CAF bugs. Read the full post Subscribe via RSS Subscribe Browse by Date November 2013 Last edited: 2016-04-29 11:34:54

  2. Cray Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reports Cray Bug Reports Viewing entries posted in November 2013 Cray C/C++ predefined _RELEASE macro returns wrong value [updated] November 18, 2013 by Mike Stewart, NERSC USG Status: Reported to Cray as bug 797442, became documentation bug 805340. Read the full post Subscribe via RSS Subscribe Browse by Date November 2013 Last edited: 2016-04-29 11:34:26

  3. PGI Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    June 2015 Internal compiler error for function pointer with identically named arguments June 9, 2015 by Scott French, NERSC USG Status: Bug 21435 reported to PGI...

  4. UPC Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    upc-bug-reportsrss Deadlock during first touch of upcalloc'd remote memory when target is in upcbarrier updated http:www.nersc.govuserssoftwarecompilers...

  5. Intel Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    intel-fortran-c-and-cintel-bug-reportsrss Intel C++ compiler error: stliteratorbasetypes.h http:www.nersc.govuserssoftwarecompilersintel-fortran-c-and-c...

  6. Early Markets: Fuel Cells for Backup Power

    Office of Energy Efficiency and Renewable Energy (EERE)

    This fact sheet describes the advantages of using fuel cell technology for application in emergency backup power.

  7. Fall 2013 Composite Data Products - Backup Power

    SciTech Connect (OSTI)

    Kurtz, J.; Sprik, S.; Ainscough, C.; Saur, G.; Post, M.; Peters, M.

    2013-12-01

    This report includes 28 composite data products (CDPs) produced in Fall 2013 for fuel cell backup power systems.

  8. Spring 2014 Composite Data Products: Backup Power

    SciTech Connect (OSTI)

    Kurtz, J.; Sprik, S.; Saur, G.

    2014-06-01

    This report includes 30 composite data products (CDPs) produced in Spring 2014 for fuel cell backup power systems.

  9. PGI Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    November 2013 Does not take an "=" as part of the name of a source file. November 12, 2013 by Mike Stewart, NERSC USG STATUS: Bug 19671 filed with PGI.

  10. UPC Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    » UPC Bug Reports UPC Bug Reports Deadlock during first touch of upc_alloc'd remote memory when target is in upc_barrier [updated] October 16, 2014 Status: This has been reported to Cray (811537) and a workaround is available. Fixed in CCE 8.3.5. Read the full post Subscribe via RSS Subscribe Browse by Date October 2014 Last edited: 2016-04-29 11:34:42

  11. Intel Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    January 2014 Invoking any Intel compiler with a Cray wrapper with -g defaults to -O2 optimization contrary to the Intel compiler man pages January 30, 2014 Status: Filed bug 776949 with Cray but they regard it as an Intel feature. Read the full post Intel uses very old version of libstdc++ by default [updated] January 15, 2014 by Mike Stewart, NERSC USG Status: Reported to Cray as case 84319, became bug 806610

  12. Backup Power Installed for WIPP EOC

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Backup Power Installed for WIPP EOC The Waste Isolation Pilot Plant's (WIPP) Emergency Operations Center (EOC) will soon have guaranteed operation in the event of a power outage. ...

  13. Fuel Cell Backup Power Technology Validation (Presentation)

    SciTech Connect (OSTI)

    Kurtz, J.; Sprik, S.; Ramsden, T.; Saur, G.

    2012-10-01

    Presentation about fuel cell backup power technology validation activities at the U.S. Department of Energy's National Renewable Energy Laboratory.

  14. Backup power sources for DOE facilities

    SciTech Connect (OSTI)

    Not Available

    1994-09-01

    This standard establishes fundamental requirements and guidance for backup power sources at DOE facilities. Purpose is to document good engineering practices for installation, testing, and maintenance of these backup power sources, which also covers emergency power sources. Examples are those which supply power to nuclear safety systems, radiation monitors and alarms, fire protection systems, security systems, and emergency lighting.

  15. Intel Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Intel » Intel Bug Reports Intel Bug Reports Intel C++ compiler error: stl_iterator_base_types.h December 7, 2015 by Scott French Because the system-supplied version of GCC is relatively old (4.3.4) it is common practice to load the gcc module on our Cray systems when C++11 support is required under the Intel C++ compilers. Read the full post C++11 header files appear missing on Edison December 3, 2014 by Scott French, NERSC USG Status: Reported to Cray (801693), Workaround available Read the

  16. Microsoft Word - BUGS_The Next Smart Grid Peak Resource Final...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Capacity of Dispersed and Distributed Generators Installed per Year by Technology Type (MW) Internal Combustion Combustion Turbine Steam Turbine Hydropower Wind and Other MW Backup ...

  17. Spring 2013 Composite Data Products - Backup Power

    SciTech Connect (OSTI)

    Kurtz, J.; Wipke, K.; Sprik, S.; Ramsden, T.; Ainscough, C.; Saur, G.; Post, M.; Peters, M.

    2013-05-01

    This presentation from the U.S. Department of Energy's National Renewable Energy Laboratory includes 21 composite data products (CDPs) produced in Spring 2013 for fuel cell backup power systems.

  18. UPC Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reports UPC Bug Reports Viewing entries posted in October 2014 Deadlock during first touch of upc_alloc'd remote memory when target is in upc_barrier [updated] October 16, 2014 Status: This has been reported to Cray (811537) and a workaround is available. Fixed in CCE 8.3.5. Read the full post Subscribe via RSS Subscribe Browse by Date October 2014 Last edited: 2016-04-29 11:34:42

  19. Fuel Cells for Backup Power in Telecommunications Facilities (Fact Sheet)

    Office of Energy Efficiency and Renewable Energy (EERE)

    Telecommunications providers rely on backup power to maintain a constant power supply, to prevent power outages, and to ensure the operability of cell towers, equipment, and networks. The backup power supply that best meets these objectives is fuel cell technology.

  20. Fuel Cells for Backup Power in Telecommunications Facilities (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2009-04-01

    Telecommunications providers rely on backup power to maintain a constant power supply, to prevent power outages, and to ensure the operability of cell towers, equipment, and networks. The backup power supply that best meets these objectives is fuel cell technology.

  1. Fuel Cells for Critical Communications Backup Power

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    for Critical Communications Backup Power Greg Moreland SENTECH, Inc. Supporting the U.S. Department of Energy August 6, 2008 APCO Annual Conference and Expo 2 2 Fuel cells use hydrogen to create electricity, with only water and heat as byproducts Fuel Cell Overview * An individual fuel cell produces about 1 volt * Hundreds of individual cells can comprise a fuel cell stack * Fuel cells can be used to power a variety of applications -Bibliographic Database * Laptop computers (50-100 W) *

  2. Fuel Cells for Critical Communications Backup Power | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    for Critical Communications Backup Power Fuel Cells for Critical Communications Backup Power This presentation provides information about using fuel cells for emergency backup power for critical communications. It was given by Greg Moreland at the Association of Public Communications Officials Annual Conference in August 2008. Posted on this Web site with permission from the author. mt_moreland_apco_presentation.pdf (3.6 MB) More Documents & Publications Overview of the DOE Hydrogen Program

  3. Departments of Energy, Defense Partner to Install Fuel Cell Backup...

    Energy Savers [EERE]

    Energy, Defense Partner to Install Fuel Cell Backup Power Units at Eight Military ... The primary challenge facing currently available fuel cells is the higher first cost ...

  4. DOE-DOD Emergency Backup Power Fuel Cell Installations

    SciTech Connect (OSTI)

    Fuel Cell Technologies Program

    2012-06-01

    Ths fact sheet describes a collaboration between the departments of Energy and Defense to install and operate 18 fuel cell backup power systems across the United States.

  5. DOE-DOD Emergency Backup Power Fuel Cell Installations

    Fuel Cell Technologies Publication and Product Library (EERE)

    Ths fact sheet describes a collaboration between the departments of Energy and Defense to install and operate 18 fuel cell backup power systems across the United States.

  6. Backup Power Cost of Ownership Analysis and Incumbent Technology...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... option for telecommunications operations that need reliable, long-running backup power at cellular phone signal relay sites, particularly during electric grid power outages. ...

  7. Fuel Cells for Backup Power in Telecommunications Facilities...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Telecommunications providers rely on backup power to maintain a constant power supply, to prevent power outages, and to ensure the operability of cell towers, equipment, and ...

  8. T-707: Apache Tomcat AJP Protocol Processing Bug Lets Remote...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AJP Protocol Processing Bug Lets Remote Users Bypass Authentication or Obtain Information T-707: Apache Tomcat AJP Protocol Processing Bug Lets Remote Users Bypass Authentication...

  9. V-202: Cisco Video Surveillance Manager Bugs Let Remote Users...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Video Surveillance Manager Bugs Let Remote Users Obtain Potentially Sensitive Information V-202: Cisco Video Surveillance Manager Bugs Let Remote Users Obtain Potentially Sensitive...

  10. V-149: Microsoft Internet Explorer Object Access Bug Lets Remote...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    9: Microsoft Internet Explorer Object Access Bug Lets Remote Users Execute Arbitrary Code V-149: Microsoft Internet Explorer Object Access Bug Lets Remote Users Execute Arbitrary...

  11. U-047: Siemens Automation License Manager Bugs Let Remote Users...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    7: Siemens Automation License Manager Bugs Let Remote Users Deny Service or Execute Arbitrary Code U-047: Siemens Automation License Manager Bugs Let Remote Users Deny Service or...

  12. Distributed Generation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Untapped Value of Backup Generation While new guidelines and regulations such as IEEE (Institute of Electrical and Electronics Engineers) 1547 have come a long way in addressing interconnection standards for distributed generation, utilities have largely overlooked the untapped potential of these resources. Under certain conditions, these units (primarily backup generators) represent a significant source of power that can deliver utility services at lower costs than traditional centralized

  13. DOE-DOD Emergency Backup Power Fuel Cell Installations | Department...

    Broader source: Energy.gov (indexed) [DOE]

    Ths fact sheet describes a collaboration between the departments of Energy and Defense to install and operate 18 fuel cell backup power systems across the United States. DOE-DOD ...

  14. Fuel Cell Systems for Portable, Backup, and UPS Applications

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    U.S. Federal Agency Purchasing Managers Federal Agency Purchasing Managers Fuel Cell Systems for Portable, Backup and UPS Fuel Cell Systems for Portable, Backup and UPS Applications Applications Eric Simpkins, USFCC President Eric Simpkins, USFCC President Vice President, IdaTech, LLC Vice President, IdaTech, LLC Washington, DC Washington, DC April 26, 2007 April 26, 2007 Definitions Introduction What's Available & How Used Typical Operation & Maintenance Time: Order to Site Installation

  15. Back-Up/ Peak Shaving Fuel Cell System

    SciTech Connect (OSTI)

    Staudt, Rhonda L.

    2008-05-28

    This Final Report covers the work executed by Plug Power from 8/11/03 10/31/07 statement of work for Topic 2: advancing the state of the art of fuel cell technology with the development of a new generation of commercially viable, stationary, Back-up/Peak-Shaving fuel cell systems, the GenCore II. The Program cost was $7.2 M with the Department of Energy share being $3.6M and Plug Powers share being $3.6 M. The Program started in August of 2003 and was scheduled to end in January of 2006. The actual program end date was October of 2007. A no cost extension was grated. The Department of Energy barriers addressed as part of this program are: Technical Barriers for Distributed Generation Systems: o Durability o Power Electronics o Start up time Technical Barriers for Fuel Cell Components: o Stack Material and Manufacturing Cost o Durability o Thermal and water management Background The next generation GenCore backup fuel cell system to be designed, developed and tested by Plug Power under the program is the first, mass-manufacturable design implementation of Plug Powers GenCore architected platform targeted for battery and small generator replacement applications in the telecommunications, broadband and UPS markets. The next generation GenCore will be a standalone, H2 in-DC-out system. In designing the next generation GenCore specifically for the telecommunications market, Plug Power is teaming with BellSouth Telecommunications, Inc., a leading industry end user. The final next generation GenCore system is expected to represent a market-entry, mass-manufacturable and economically viable design. The technology will incorporate: A cost-reduced, polymer electrolyte membrane (PEM) fuel cell stack tailored to hydrogen fuel use An advanced electrical energy storage system A modular, scalable power conditioning system tailored to market requirements A scaled-down, cost-reduced balance of plant (BOP) Network Equipment Building Standards (NEBS), UL and CE

  16. RELAP5-3D Restart and Backup Verification Testing

    SciTech Connect (OSTI)

    Dr. George L Mesina

    2013-09-01

    Existing testing methodology for RELAP5-3D employs a set of test cases collected over two decades to test a variety of code features and run on a Linux or Windows platform. However, this set has numerous deficiencies in terms of code coverage, detail of comparison, running time, and testing fidelity of RELAP5-3D restart and backup capabilities. The test suite covers less than three quarters of the lines of code in the relap directory and just over half those in the environmental library. Even in terms of code features, many are not covered. Moreover, the test set runs many problems long past the point necessary to test the relevant features. It requires standard problems to run to completion. This is unnecessary for features can be tested in a short-running problem. For example, many trips and controls can be tested in the first few time steps, as can a number of fluid flow options. The testing system is also inaccurate. For the past decade, the diffem script has been the primary tool for checking that printouts from two different RELAP5-3D executables agree. This tool compares two output files to verify that all characters are the same except for those relating to date, time and a few other excluded items. The variable values printed on the output file are accurate to no more than eight decimal places. Therefore, calculations with errors in decimal places beyond those printed remain undetected. Finally, fidelity of restart is not tested except in the PVM sub-suite and backup is not specifically tested at all. When a restart is made from any midway point of the base-case transient, the restart must produce the same values. When a backup condition occurs, the code repeats advancements with the same time step. A perfect backup can be tested by forcing RELAP5 to perform a backup by falsely setting a backup condition flag at a user-specified-time. Comparison of the calculations of that run and those produced by the same input w/o the spurious condition should be

  17. Hydrogen Fuel Cells Backup Infrastructure Cleanly and Quietly | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy Hydrogen Fuel Cells Backup Infrastructure Cleanly and Quietly Hydrogen Fuel Cells Backup Infrastructure Cleanly and Quietly August 25, 2010 - 1:00pm Addthis Sprint Nextel Corp. is deploying new fuel cells - such as these from ReliOn - to sites throughout the country. | Photo courtesy of Sprint Nextel Corp. Sprint Nextel Corp. is deploying new fuel cells - such as these from ReliOn - to sites throughout the country. | Photo courtesy of Sprint Nextel Corp. Maya Payne Smart Former

  18. DOE-DOD Emergency Backup Power Fuel Cell Installations

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    DOE-DOD Emergency Backup Power Fuel Cell Installations On July 19, 2011, the U.S. Department of Energy (DOE) announced that, as part of an interagency partnership with the U.S. Department of Defense (DOD) to strengthen American energy security and develop new clean energy technologies, DOE and DOD will collaborate on a project to install and operate 18 fuel cell backup power systems at eight defense installations across the country. The Departments will test how the fuel cells perform in real

  19. Early Markets: Fuel Cells for Backup Power

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of 8, 52, 72, or 176 hours. In this analysis the fuel cell system with incentives ... with the diesel generator, in the 8-hour, ... FCBP systems 1.99 MW Total installed ...

  20. V-127: Samba Bug Lets Remote Authenticated Users Modify Files...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    7: Samba Bug Lets Remote Authenticated Users Modify Files V-127: Samba Bug Lets Remote Authenticated Users Modify Files April 5, 2013 - 6:00am Addthis PROBLEM: A vulnerability was...

  1. There are currently no significant reported user bugs with the...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    no significant reported user bugs with the GNU compilers. November 18, 2013 by Mike Stewart, NERSC USG. Status: No current NERSC user bugs. Subscribe via RSS Subscribe Browse by...

  2. Fuel Cell Backup Power Geographical Visualization Map (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2012-12-01

    This NREL Hydrogen and Fuel Cell Technical Highlight describes a time-lapse geographical visualization map of early market use of fuel cells for telecommunications backup power. The map synthesizes data being analyzed by NREL's Technology Validation team for the U.S. Department of Energy (DOE) Fuel Cell Technologies Program with DOE's publicly available annual summaries of electric disturbance events.

  3. There are currently no significant reported user bugs with CAF.

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reports » There are currently no significant reported user bugs with CAF. There are currently no significant reported user bugs with CAF. November 18, 2013 No reported CAF bugs. Subscribe via RSS Subscribe Browse by Date November 2013 Last edited: 2013-11-18 15:10:05

  4. Mining Bug Databases for Unidentified Software Vulnerabilities

    SciTech Connect (OSTI)

    Dumidu Wijayasekara; Milos Manic; Jason Wright; Miles McQueen

    2012-06-01

    Identifying software vulnerabilities is becoming more important as critical and sensitive systems increasingly rely on complex software systems. It has been suggested in previous work that some bugs are only identified as vulnerabilities long after the bug has been made public. These vulnerabilities are known as hidden impact vulnerabilities. This paper discusses the feasibility and necessity to mine common publicly available bug databases for vulnerabilities that are yet to be identified. We present bug database analysis of two well known and frequently used software packages, namely Linux kernel and MySQL. It is shown that for both Linux and MySQL, a significant portion of vulnerabilities that were discovered for the time period from January 2006 to April 2011 were hidden impact vulnerabilities. It is also shown that the percentage of hidden impact vulnerabilities has increased in the last two years, for both software packages. We then propose an improved hidden impact vulnerability identification methodology based on text mining bug databases, and conclude by discussing a few potential problems faced by such a classifier.

  5. DOE Technical Targets for Fuel Cell Backup Power Systems | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Backup Power Systems DOE Technical Targets for Fuel Cell Backup Power Systems This table lists the U.S. Department of Energy (DOE) technical targets for fuel cell backup power systems. More information about targets can be found in the Fuel Cells section of the Fuel Cell Technologies Office's Multi-Year Research, Development, and Demonstration Plan. Technical Targets: Fuel Cell Backup Power Systems (1-10kWe) Operating on Direct Hydrogen Characteristic Units 2015 Statusa 2020 Targets

  6. V-115: Apple iOS Bugs Let Local Users Gain Elevated Privileges...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    5: Apple iOS Bugs Let Local Users Gain Elevated Privileges V-115: Apple iOS Bugs Let Local Users Gain Elevated Privileges March 20, 2013 - 12:08am Addthis PROBLEM: Apple iOS Bugs...

  7. U-279: Cisco Firewall Services Module Bugs Let Remote Users Execute...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    79: Cisco Firewall Services Module Bugs Let Remote Users Execute Arbitrary Code and Deny Service U-279: Cisco Firewall Services Module Bugs Let Remote Users Execute Arbitrary Code ...

  8. U-159: Red Hat Enterprise MRG Messaging Qpid Bug Lets Certain...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    9: Red Hat Enterprise MRG Messaging Qpid Bug Lets Certain Remote Users Bypass Authentication U-159: Red Hat Enterprise MRG Messaging Qpid Bug Lets Certain Remote Users Bypass...

  9. V-146: HP Service Manager Bugs Permit Cross-Site Scripting and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    6: HP Service Manager Bugs Permit Cross-Site Scripting and Information Disclosure Attacks V-146: HP Service Manager Bugs Permit Cross-Site Scripting and Information Disclosure...

  10. U-241: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    1: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary Code and Obtain Information U-241: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary Code and Obtain...

  11. U-005: Apache mod_proxy Pattern Matching Bug Lets Remote Users...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    5: Apache modproxy Pattern Matching Bug Lets Remote Users Access Internal Servers U-005: Apache modproxy Pattern Matching Bug Lets Remote Users Access Internal Servers October 6,...

  12. U-142: HP Onboard Administrator Bugs Let Remote Users Gain Access...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    2: HP Onboard Administrator Bugs Let Remote Users Gain Access, Obtain Information, and Conduct URL Redirection Attacks U-142: HP Onboard Administrator Bugs Let Remote Users Gain...

  13. U-046: Apache mod_proxy/mod_rewrite Bug Lets Remote Users Access...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    6: Apache modproxymodrewrite Bug Lets Remote Users Access Internal Servers U-046: Apache modproxymodrewrite Bug Lets Remote Users Access Internal Servers November 28, 2011 -...

  14. There are currently no significant reported user bugs with CAF...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    1-800-66-NERSC, option 3 or 510-486-8611 Home For Users Software Compilers CAF (Coarray Fortran) CAF Bug Reports There are currently no significant...

  15. Microsoft Word - Final BUGS article final.docx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Characteristics of a Good Peak Resource Demand Response Program Central- Station Peaker BUGS for Peaks Close to the Load Dispatchable Rapidly Deployable (< 2 ...

  16. Membrane Requirements for Back-up Power Applications | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Requirements for Back-up Power Applications Membrane Requirements for Back-up Power Applications Presentation at the DOE High Temperature Work Group Meetings Nov. 16, 2009, Palm Springs, CA htmwg_nov09_membrane_requirements.pdf (276.69 KB) More Documents & Publications Minutes of the Fall 2009 High Temperature Membrane Working Group Fuel Cell Systems for Portable, Backup, and UPS Applications 2008 Fuel Cell Technologies Market Report

  17. Accelerating Acceptance of Fuel Cell Backup Power Systems - Final Report

    SciTech Connect (OSTI)

    Petrecky, James; Ashley, Christopher

    2014-07-21

    Since 2001, Plug Power has installed more than 800 stationary fuel cell systems worldwide. Plug Power’s prime power systems have produced approximately 6.5 million kilowatt hours of electricity and have accumulated more than 2.5 million operating hours. Intermittent, or backup, power products have been deployed with telecommunications carriers and government and utility customers in North and South America, Europe, the United Kingdom, Japan and South Africa. Some of the largest material handling operations in North America are currently using the company’s motive power units in fuel cell-powered forklifts for their warehouses, distribution centers and manufacturing facilities. The low-temperature GenSys fuel cell system provides remote, off-grid and primary power where grid power is unreliable or nonexistent. Built reliable and designed rugged, low- temperature GenSys delivers continuous or backup power through even the most extreme conditions. Coupled with high-efficiency ratings, low-temperature GenSys reduces operating costs making it an economical solution for prime power requirements. Currently, field trials at telecommunication and industrial sites across the globe are proving the advantages of fuel cells—lower maintenance, fuel costs and emissions, as well as longer life—compared with traditional internal combustion engines.

  18. V-006: CA ARCserve Backup Flaws Let Remote Users Execute Arbitrary Code and Deny Service

    Broader source: Energy.gov [DOE]

    Two vulnerabilities were reported in CA ARCserve Backup. A remote user can execute arbitrary code on the target system. A remote user can cause denial of service conditions.

  19. T-707: Apache Tomcat AJP Protocol Processing Bug Lets Remote Users Bypass Authentication or Obtain Information

    Broader source: Energy.gov [DOE]

    Apache Tomcat AJP protocol processing bug lets remote users bypass authentication or obtain information.

  20. Microsoft Word - Final BUGS article final.docx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    October 18, 2010 DOE/NETL-2010/1435 BUGS: The Next Smart Grid Peak Resource? BUGS: The Next Smart Grid Peak Resource? 2 Prepared by: Booz Allen Hamilton (BAH) Steve Pullins Horizon Energy Group DOE Contract number: DE-FE000400 BUGS: The Next Smart Grid Peak Resource? 3 Acknowledgements This report was prepared by Booz Allen Hamilton, Inc. (BAH) for the United States Department of Energy's National Energy Technology Laboratory. This work was completed under DOE NETL Contract Number DE-FE000400,

  1. Hydrogen Fuel Cell Performance as Telecommunications Backup Power in the United States

    SciTech Connect (OSTI)

    Kurtz, Jennifer; Saur, Genevieve; Sprik, Sam

    2015-03-01

    Working in collaboration with the U.S. Department of Energy (DOE) and industry project partners, the National Renewable Energy Laboratory (NREL) acts as the central data repository for the data collected from real-world operation of fuel cell backup power systems. With American Recovery and Reinvestment Act of 2009 (ARRA) co-funding awarded through DOE's Fuel Cell Technologies Office, more than 1,300 fuel cell units were deployed over a three-plus-year period in stationary, material handling equipment, auxiliary power, and backup power applications. This surpassed a Fuel Cell Technologies Office ARRA objective to spur commercialization of an early market technology by installing 1,000 fuel cell units across several different applications, including backup power. By December 2013, 852 backup power units out of 1,330 fuel cell units deployed were providing backup service, mainly for telecommunications towers. For 136 of the fuel cell backup units, project participants provided detailed operational data to the National Fuel Cell Technology Evaluation Center for analysis by NREL's technology validation team. NREL analyzed operational data collected from these government co-funded demonstration projects to characterize key fuel cell backup power performance metrics, including reliability and operation trends, and to highlight the business case for using fuel cells in these early market applications. NREL's analyses include these critical metrics, along with deployment, U.S. grid outage statistics, and infrastructure operation.

  2. V-098: Linux Kernel Extended Verification Module Bug Lets Local...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    reported in the Linux Kernel. REFERENCE LINKS: The Linux Kernel Archives Linux Kernel Red Hat Bugzilla - Bug 913266 SecurityTracker Alert ID: 1028196 CVE-2013-0313 IMPACT...

  3. V-128: Xen Event Channel Tracking Pointer Bug Local Privilege...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Channel Tracking Pointer Bug Local Privilege Escalation April 8, 2013 - 12:28am Addthis PLATFORM: Version(s): 3.2 and later ABSTRACT: A vulnerability was reported in Xen....

  4. 2014-02-21 Issuance: Proposed Determination of Computer and Battery Backup

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Systems as a Covered Consumer Product | Department of Energy and Battery Backup Systems as a Covered Consumer Product 2014-02-21 Issuance: Proposed Determination of Computer and Battery Backup Systems as a Covered Consumer Product This document is a pre-publication Federal Register notice of proposed determination regarding computer systems, as issued by the Deputy Assistant Secretary for Energy Efficiency on February 21, 2014. Though it is not intended or expected, should any discrepancy

  5. 2014-03-26 Issuance: Proposed Determination of Computer and Battery Backup

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Systems as a Covered Consumer Product; Extension of Public Comment Period | Department of Energy 26 Issuance: Proposed Determination of Computer and Battery Backup Systems as a Covered Consumer Product; Extension of Public Comment Period 2014-03-26 Issuance: Proposed Determination of Computer and Battery Backup Systems as a Covered Consumer Product; Extension of Public Comment Period This document is a pre-publication Federal Register notice extending the public comment period for the

  6. V-189: Oracle VirtualBox 'tracepath' Bug Lets Local Guest Users...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Oracle VirtualBox 'tracepath' Bug Lets Local Guest Users Deny Service on the Target Host V-189: Oracle VirtualBox 'tracepath' Bug Lets Local Guest Users Deny Service on the Target...

  7. V-113: Apple Safari Bugs Let Remote Users Execute Arbitrary Code...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    3: Apple Safari Bugs Let Remote Users Execute Arbitrary Code V-113: Apple Safari Bugs Let Remote Users Execute Arbitrary Code March 18, 2013 - 1:53am Addthis PROBLEM: Apple Safari...

  8. V-141: HP ElitePad 900 Secure Boot Bug Lets Local Users Boot...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    1: HP ElitePad 900 Secure Boot Bug Lets Local Users Boot to Other Operating Systems V-141: HP ElitePad 900 Secure Boot Bug Lets Local Users Boot to Other Operating Systems April...

  9. U-257: Adobe ColdFusion Unspecified Bug Lets Remote Users Deny...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    7: Adobe ColdFusion Unspecified Bug Lets Remote Users Deny Service U-257: Adobe ColdFusion Unspecified Bug Lets Remote Users Deny Service September 12, 2012 - 6:00am Addthis...

  10. V-203: HP LoadRunner Multiple Bugs Let Remote Users Deny Service...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    V-171: Apple Safari Bugs Let Remote Users Execute Arbitrary Code and Conduct Cross-Site Scripting Attacks V-110: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary Code...

  11. V-110: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    0: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary Code V-110: Adobe Flash Player Bugs Let Remote Users Execute Arbitrary Code March 13, 2013 - 12:04am Addthis PROBLEM:...

  12. V-140: Apache ActiveMQ Bugs Let Remote Users Conduct Cross-Site...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    0: Apache ActiveMQ Bugs Let Remote Users Conduct Cross-Site Scripting Attacks, Deny Service, and Obtain Potentially Sensitive Information V-140: Apache ActiveMQ Bugs Let Remote...

  13. U-029: TCP/IP Services for OpenVMS POP/IMAP Service Bug Lets...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    9: TCPIP Services for OpenVMS POPIMAP Service Bug Lets Remote Users Gain Unauthorized Access U-029: TCPIP Services for OpenVMS POPIMAP Service Bug Lets Remote Users Gain...

  14. V-071: Cisco ASA 1000V Cloud Firewall H.323 Inspection Bug Lets...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    1: Cisco ASA 1000V Cloud Firewall H.323 Inspection Bug Lets Remote Users Deny Service V-071: Cisco ASA 1000V Cloud Firewall H.323 Inspection Bug Lets Remote Users Deny Service ...

  15. There are currently no significant reported user bugs with the GNU

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    compilers. Reports » There are currently no significant reported user bugs with the GNU compilers. There are currently no significant reported user bugs with the GNU compilers. November 18, 2013 by Mike Stewart, NERSC USG. Status: No current NERSC user bugs. Subscribe via RSS Subscribe Browse by Date November 2013 Last edited: 2013-11-18 14:25:14

  16. Hydrogen Fuel Cell Performance in the Key Early Markets of Material Handling Equipment and Backup Power (Presentation)

    SciTech Connect (OSTI)

    Kurtz, J.; Sprik, S.; Ramsden, T.; Saur, G.; Ainscough, C.; Post, M.; Peters, M.

    2013-10-01

    This presentation summarizes the results of NREL's analysis of hydrogen fuel cell performance in the key early markets of material handling equipment (MHE) and backup power.

  17. Backup Power Cost of Ownership Analysis and Incumbent Technology...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Table 1. Key Assumptions a by Technology Battery Diesel Generator Fuel Cell Capacity (kW) 4-6 25-35 (operated at 6) 4-6 Lifetime 9 5 15 15 Leased bottles for 8- Fuel Storage ...

  18. Deep Well #4 Backup Power Systems Project Closeout Report

    SciTech Connect (OSTI)

    Jeremy Westwood

    2010-04-01

    The project scope was to install a diesel generated power source to deep well 4 in addition to the existing commercial power source. The diesel power source and its fuel supply system shall be seismically qualified to withstand a Performance Category 4 (PC-4) seismic event. This diesel power source will permit the deep well to operate during a loss of commercial power. System design will incorporate the ability to select and transfer power between the new diesel power source and commercial power sources for the the deep well motor and TRA-672 building loads.

  19. V-026: RSA Data Protection Manager Bugs Permit Cross-Site Scripting Attacks

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and Let Local Users Bypass Security Restrictions | Department of Energy 26: RSA Data Protection Manager Bugs Permit Cross-Site Scripting Attacks and Let Local Users Bypass Security Restrictions V-026: RSA Data Protection Manager Bugs Permit Cross-Site Scripting Attacks and Let Local Users Bypass Security Restrictions November 16, 2012 - 6:00am Addthis PROBLEM: RSA Data Protection Manager Bugs Permit Cross-Site Scripting Attacks and Let Local Users Bypass Security Restrictions. PLATFORM: RSA

  20. V-135: Cisco ASA Multiple Bugs Let Remote Users Deny Service | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy 5: Cisco ASA Multiple Bugs Let Remote Users Deny Service V-135: Cisco ASA Multiple Bugs Let Remote Users Deny Service April 16, 2013 - 12:21am Addthis PROBLEM: Cisco ASA Multiple Bugs Let Remote Users Deny Service PLATFORM: Cisco ASA Software for Cisco ASA 5500 Series Adaptive Security Appliances, Cisco ASA Services Module for Cisco Catalyst 6500 Series Switches and Cisco 7600 Series Routers, and Cisco ASA 1000V Cloud Firewall are affected by multiple vulnerabilities. Affected

  1. U-053: Linux kexec Bugs Let Local and Remote Users Obtain Potentially

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Sensitive Information | Department of Energy 53: Linux kexec Bugs Let Local and Remote Users Obtain Potentially Sensitive Information U-053: Linux kexec Bugs Let Local and Remote Users Obtain Potentially Sensitive Information December 7, 2011 - 7:30am Addthis PROBLEM: Linux kexec Bugs Let Local and Remote Users Obtain Potentially Sensitive Information . PLATFORM: Red Hat Enterprise Linux Desktop (v. 6) Red Hat Enterprise Linux HPC Node (v. 6) Red Hat Enterprise Linux Server (v. 6) Red Hat

  2. U-279: Cisco Firewall Services Module Bugs Let Remote Users Execute

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Arbitrary Code and Deny Service | Department of Energy 79: Cisco Firewall Services Module Bugs Let Remote Users Execute Arbitrary Code and Deny Service U-279: Cisco Firewall Services Module Bugs Let Remote Users Execute Arbitrary Code and Deny Service October 11, 2012 - 6:00am Addthis PROBLEM: Cisco Firewall Services Module Bugs Let Remote Users Execute Arbitrary Code and Deny Service PLATFORM: Version(s): prior to 4.1(9) ABSTRACT: Several vulnerabilities were reported in Cisco Firewall

  3. The California Demonstration Program for Control of PM from Diesel Backup Generators =

    Broader source: Energy.gov [DOE]

    2004 Diesel Engine Emissions Reduction (DEER) Conference Presentation: University of California, Riverside

  4. V-076: Cisco Wireless LAN Controller Bugs Let Remote Users Deny...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Cisco Wireless LAN Controller Bugs Let Remote Users Deny Service and Remote Authenticated Users Modify the Configuration and Execute Arbitrary Code V-076: Cisco Wireless LAN ...

  5. U-053: Linux kexec Bugs Let Local and Remote Users Obtain Potentially...

    Office of Environmental Management (EM)

    Linux kexec Bugs Let Local and Remote Users Obtain Potentially Sensitive Information . PLATFORM: Red Hat Enterprise Linux Desktop (v. 6) Red Hat Enterprise Linux HPC Node (v. 6) ...

  6. Electrochromism vs. the Bugs:DevelopingWO3 Thin Film Windows...

    Office of Scientific and Technical Information (OSTI)

    Title: Electrochromism vs. the Bugs:DevelopingWO3 Thin Film Windows toControl Photoactive Biological Systems. Abstract not provided. Authors: Small, Leo J ; Spoerke, Erik David ; ...

  7. U-049: IBM Tivoli Netcool Reporter CGI Bug Lets Remote Users...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    LaserJet Printers Unspecified Flaw Lets Remote Users Update Firmware with Arbitrary Code U-053: Linux kexec Bugs Let Local and Remote Users Obtain Potentially Sensitive Information

  8. U-027: RSA Key Manager Appliance Session Logout Bug Fails to...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    PROBLEM: RSA Key Manager Appliance Session Logout Bug Fails to Terminate Sessions. PLATFORM: RSA Key Manager Appliance 2.7 Service Pack 1 ABSTRACT: A remote authenticated...

  9. Electromechanical battery design suitable for back-up power applications

    DOE Patents [OSTI]

    Post, Richard F.

    2002-01-01

    The windings that couple energy into and out of the rotor of an electro-mechanical battery are modified. The normal stator windings of the generator/motor have been replaced by two orthogonal sets of windings. Because of their orthogonality, they are decoupled from each other electrically, though each can receive (or deliver) power flows from the rotating field produced by the array of permanent magnets. Due to the orthogonal design of the stator windings and the high mechanical inertia of the flywheel rotor, the resulting power delivered to the computer system is completely insensitive to any and all electrical transients and variabilities of the power from the main power source. This insensitivity includes complete failure for a period determined only by the amount of stored kinetic energy in the E-M battery modules that are supplied. Furthermore there is no need whatsoever for fast-acting, fractional-cycle switches, such as are employed in conventional systems, and which are complicated to implement.

  10. Passive cooling system for liquid metal cooled nuclear reactors with backup coolant flow path

    DOE Patents [OSTI]

    Hunsbedt, Anstein; Boardman, Charles E.

    1993-01-01

    A liquid metal cooled nuclear fission reactor plant having a passive auxiliary safety cooling system for removing residual heat resulting from fuel decay during reactor shutdown, or heat produced during a mishap. This reactor plant is enhanced by a backup or secondary passive safety cooling system which augments the primary passive auxiliary cooling system when in operation, and replaces the primary system when rendered inoperable.

  11. Economic Impact of Fuel Cell Deployment in Forklifts and for Backup Power under the American Recovery and Reinvestment Act

    Broader source: Energy.gov [DOE]

    This report presents estimates of economic impacts associated with expenditures under the ARRA, also known as the Recovery Act, by the USDOE for the deployment of fuel cells in forklift and backup power applications.

  12. U-049: IBM Tivoli Netcool Reporter CGI Bug Lets Remote Users Inject

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Commands on the Target System | Department of Energy 49: IBM Tivoli Netcool Reporter CGI Bug Lets Remote Users Inject Commands on the Target System U-049: IBM Tivoli Netcool Reporter CGI Bug Lets Remote Users Inject Commands on the Target System December 1, 2011 - 9:00am Addthis PROBLEM: IBM Tivoli Netcool Reporter CGI Bug Lets Remote Users Inject Commands on the Target System. PLATFORM: IBM Tivoli Netcool Reporter prior to 2.2.0.8 ABSTRACT: A vulnerability was reported in IBM Tivoli Netcool

  13. V-071: Cisco ASA 1000V Cloud Firewall H.323 Inspection Bug Lets Remote

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Users Deny Service | Department of Energy 1: Cisco ASA 1000V Cloud Firewall H.323 Inspection Bug Lets Remote Users Deny Service V-071: Cisco ASA 1000V Cloud Firewall H.323 Inspection Bug Lets Remote Users Deny Service January 17, 2013 - 12:00am Addthis PROBLEM: Cisco ASA 1000V Cloud Firewall H.323 Inspection Bug Lets Remote Users Deny Service PLATFORM: The vulnerability is reported in versions 8.7.1 and 8.7.1.1. ABSTRACT: A vulnerability has been reported in Cisco ASA 1000V Cloud Firewall

  14. V-151: RSA Archer eGRC Bugs Let Remote Authenticated Users Upload Files and

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Let Remote Users Conduct Cross-Site Scripting Attacks | Department of Energy 51: RSA Archer eGRC Bugs Let Remote Authenticated Users Upload Files and Let Remote Users Conduct Cross-Site Scripting Attacks V-151: RSA Archer eGRC Bugs Let Remote Authenticated Users Upload Files and Let Remote Users Conduct Cross-Site Scripting Attacks May 8, 2013 - 12:06am Addthis PROBLEM: RSA Archer eGRC Bugs Let Remote Authenticated Users Upload Files and Let Remote Users Conduct Cross-Site Scripting Attacks

  15. Long-Baseline Neutrino Experiment (LBNE)Water Cherenkov Detector Basis of Estimate Forms and Backup Documentation LBNE Far Site Internal Review (December 6-9, 2011)

    SciTech Connect (OSTI)

    Stewart J.; Diwan, M.; Dolph, J.; Novakova, P.; Sharma, R.; Stewart, J.; Viren, B.; Russo, T.; Kaducak, M.; Mantsch, P.; Paulos, B.; Feyzi, F.; Sullivan, G.; Bionta, R.; Fowler, J.; Warner, D.; Bahowick, S.; Van Berg, R.; Kearns, E.; Hazen, E.; Sinnis, G.; Sanchez, M.

    2011-12-09

    Basis of Estimate (BOE) forms and backup documentation developed for the Water Cherenkov Detector (WCD) option for the far detector of the Long Baseline Neutrino Experiment (LBNE)

  16. Development of a gas backup heater for solar domestic hot-water systems. Final report, April 1978-April 1980

    SciTech Connect (OSTI)

    Morrison, D.J.; Grunes, H.E.; de Winter, F.; Armstrong, P.R.

    1980-06-01

    A comprehensive program was undertaken to develop a unique gas fired backup for solar domestic hot water systems. Detailed computer design tools were written. A series of heat transfer experiments were performed to characterize the performance of individual components. A full scale engineering prototype, including the solar preheat tank and solar heat exchanger, was designed, fabricated and subjected to limited testing. Firing efficiency for the backup system was found to be 81.4% at a firing rate of 50,000 Btu/h. Long term standby losses should be negligible.

  17. U-068:Linux Kernel SG_IO ioctl Bug Lets Local Users Gain Elevated...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Linux Kernel SGIO ioctl Bug Lets Local Users Gain Elevated Privileges PLATFORM: Red Hat Enterprise Linux Desktop (v. 6) Red Hat Enterprise Linux HPC Node (v. 6) Red Hat...

  18. V-183: Cisco TelePresence TC and TE Bugs Let Remote Users Deny...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Remote Users Deny Service and Remote Adjacent Authenticated Users Gain Root Shell Access V-183: Cisco TelePresence TC and TE Bugs Let Remote Users Deny Service and Remote Adjacent...

  19. V-151: RSA Archer eGRC Bugs Let Remote Authenticated Users Upload...

    Energy Savers [EERE]

    Users Upload Files and Let Remote Users Conduct Cross-Site Scripting Attacks V-151: RSA Archer eGRC Bugs Let Remote Authenticated Users Upload Files and Let Remote Users ...

  20. V-076: Cisco Wireless LAN Controller Bugs Let Remote Users Deny Service and

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Remote Authenticated Users Modify the Configuration and Execute Arbitrary Code | Department of Energy 6: Cisco Wireless LAN Controller Bugs Let Remote Users Deny Service and Remote Authenticated Users Modify the Configuration and Execute Arbitrary Code V-076: Cisco Wireless LAN Controller Bugs Let Remote Users Deny Service and Remote Authenticated Users Modify the Configuration and Execute Arbitrary Code January 24, 2013 - 6:00am Addthis PROBLEM: Several vulnerabilities were reported in

  1. RELAP5-3D Resolution of Known Restart/Backup Issues

    SciTech Connect (OSTI)

    Mesina, George L.; Anderson, Nolan A.

    2014-12-01

    The state-of-the-art nuclear reactor system safety analysis computer program developed at the Idaho National Laboratory (INL), RELAP5-3D, continues to adapt to changes in computer hardware and software and to develop to meet the ever-expanding needs of the nuclear industry. To continue at the forefront, code testing must evolve with both code and industry developments, and it must work correctly. To best ensure this, the processes of Software Verification and Validation (V&V) are applied. Verification compares coding against its documented algorithms and equations and compares its calculations against analytical solutions and the method of manufactured solutions. A form of this, sequential verification, checks code specifications against coding only when originally written then applies regression testing which compares code calculations between consecutive updates or versions on a set of test cases to check that the performance does not change. A sequential verification testing system was specially constructed for RELAP5-3D to both detect errors with extreme accuracy and cover all nuclear-plant-relevant code features. Detection is provided through a “verification file” that records double precision sums of key variables. Coverage is provided by a test suite of input decks that exercise code features and capabilities necessary to model a nuclear power plant. A matrix of test features and short-running cases that exercise them is presented. This testing system is used to test base cases (called null testing) as well as restart and backup cases. It can test RELAP5-3D performance in both standalone and coupled (through PVM to other codes) runs. Application of verification testing revealed numerous restart and backup issues in both standalone and couple modes. This document reports the resolution of these issues.

  2. SU-E-T-33: An EPID-Based Method for Testing Absolute Leaf Position for MLC Without Backup Jaws

    SciTech Connect (OSTI)

    Hancock, S; Whitaker, M

    2014-06-01

    Purpose: Methods in common use for MLC leaf position QA are limited to measurements relative to an arbitrary reference position. The authors previously presented an EPID-based method for efficiently testing accuracy of leaf position relative to the mechanical isocenter for MLC with backup jaws. The purpose of this work is to extend that method to the general case of MLC without backup jaws. Methods: A pair of collimator walkout images is used to determine the location of the mechanical isocenter relative to the center of one field using a parameter called X-offset. The method allows for shift of the imager panel to cover subsets of MLC leaves within the limited field of view of the imager. For a shifted panel position, an image of three beam strips defined by a subset of MLC leaves allows determination of the position of each leaf relative to the isocenter. The location of the isocenter is determined by applying X-offset to an image of a single rectangular field obtained at that panel position. The method can also be used to test backup jaws instead of MLC leaves. A software tool was developed to efficiently analyze the images. Results: The software tool reports leaf position and deviation from nominal position, and provides visual displays to facilitate rapid qualitative interpretation. Test results using this method agree well with results using the previous method requiring backup jaws. Test results have been successfully used to recalibrate one model MLC (Elekta MLCi2™). Work in progress includes extension of the software tool to other MLC models, and quantification of reproducibility of the measurements. Conclusion: This work successfully demonstrates a method to efficiently and accurately measure MLC leaf position, or backup jaw position, relative to the mechanical isocenter of the collimator.

  3. T-568: Mozilla Firefox Bugs Let Remote Users Conduct Cross-Site Request Forgery Attacks and Execute Arbitrary Code

    Broader source: Energy.gov [DOE]

    Mozilla developers identified and fixed several memory safety bugs in the browser engine used in Firefox and other Mozilla-based products. Some of these bugs showed evidence of memory corruption under certain circumstances, and Mozilla presume that with enough effort at least some of these could be exploited to run arbitrary code.

  4. PV based systems, with wind, diesel or LPG genset backup, supplying small TV rebroadcast stations in Portugal

    SciTech Connect (OSTI)

    Ramos, H.F.

    1994-12-31

    This paper describes the implementation of a program intended to introduce PV based hybrid power systems to supply electrical power to small size TV rebroadcast stations in Portugal. Reliability is a major concern to this type of application, as well as economical and social constraints, so wind or diesel/LPG genset backup are used. This paper includes a description of the systems behavior, comparison among these topologies and economical viability data from a users viewpoint.

  5. T-712: Red Hat Enterprise MRG Grid 2.0 security, bug fix and enhancement

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    update | Department of Energy 12: Red Hat Enterprise MRG Grid 2.0 security, bug fix and enhancement update T-712: Red Hat Enterprise MRG Grid 2.0 security, bug fix and enhancement update September 8, 2011 - 10:30am Addthis PROBLEM: A flaw was discovered in Cumin where it would log broker authentication credentials to the Cumin log file. A vulnerability was reported in Red Hat Enterprise MRG Grid. A local user can access the broker password. PLATFORM: Red Hat Enterprise MRG v2 for Red Hat

  6. T-712: Red Hat Enterprise MRG Grid 2.0 security, bug fix and enhancement

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    update | Department of Energy 12: Red Hat Enterprise MRG Grid 2.0 security, bug fix and enhancement update T-712: Red Hat Enterprise MRG Grid 2.0 security, bug fix and enhancement update September 8, 2011 - 10:30am Addthis PROBLEM: A flaw was discovered in Cumin where it would log broker authentication credentials to the Cumin log file. A vulnerability was reported in Red Hat Enterprise MRG Grid. A local user can access the broker password. PLATFORM: Red Hat Enterprise MRG v2 for Red Hat

  7. Measuring "Real World" Heavy-Duty Diesel Emissions with a Mobile Lab |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy "Real World" Heavy-Duty Diesel Emissions with a Mobile Lab Measuring "Real World" Heavy-Duty Diesel Emissions with a Mobile Lab 2002 DEER Conference Presentation: University of California, Riverside 2002_deer_miller.pdf (1.13 MB) More Documents & Publications The California Demonstration Program for Control of PM from Diesel Backup Generators (BUGs) The California Demonstration Program for Control of PM from Diesel Backup Generators = Recent

  8. DOE-STD-3003-2000; Backup Power Sources for DOE Facilities

    Broader source: Energy.gov (indexed) [DOE]

    ... This can be seen from a University of Dayton Research Institute study of diesel generator ... Expected operating cycles and hours for the design lifetime (this should include ...

  9. V-012: Mozilla Firefox 'window.location' Bugs Permit Cross-Site Scripting Attacks and May Let Remote Users Execute Arbitrary Code

    Broader source: Energy.gov [DOE]

    PROBLEM: Mozilla Firefox 'window.location' Bugs Permit Cross-Site Scripting Attacks and May Let Remote Users Execute Arbitrary Code

  10. A Total Cost of Ownership Model for Low Temperature PEM Fuel Cells in Combined Heat and Power and Backup Power Applications

    SciTech Connect (OSTI)

    University of California, Berkeley; Wei, Max; Lipman, Timothy; Mayyas, Ahmad; Chien, Joshua; Chan, Shuk Han; Gosselin, David; Breunig, Hanna; Stadler, Michael; McKone, Thomas; Beattie, Paul; Chong, Patricia; Colella, Whitney; James, Brian

    2014-06-23

    A total cost of ownership model is described for low temperature proton exchange membrane stationary fuel cell systems for combined heat and power (CHP) applications from 1-250kW and backup power applications from 1-50kW. System designs and functional specifications for these two applications were developed across the range of system power levels. Bottom-up cost estimates were made for balance of plant costs, and detailed direct cost estimates for key fuel cell stack components were derived using design-for-manufacturing-and-assembly techniques. The development of high throughput, automated processes achieving high yield are projected to reduce the cost for fuel cell stacks to the $300/kW level at an annual production volume of 100 MW. Several promising combinations of building types and geographical location in the U.S. were identified for installation of fuel cell CHP systems based on the LBNL modelling tool DER CAM. Life-cycle modelling and externality assessment were done for hotels and hospitals. Reduced electricity demand charges, heating credits and carbon credits can reduce the effective cost of electricity ($/kWhe) by 26-44percent in locations such as Minneapolis, where high carbon intensity electricity from the grid is displaces by a fuel cell system operating on reformate fuel. This project extends the scope of existing cost studies to include externalities and ancillary financial benefits and thus provides a more comprehensive picture of fuel cell system benefits, consistent with a policy and incentive environment that increasingly values these ancillary benefits. The project provides a critical, new modelling capacity and should aid a broad range of policy makers in assessing the integrated costs and benefits of fuel cell systems versus other distributed generation technologies.

  11. Making the grid the backup: Utility applications for fuel cell power

    SciTech Connect (OSTI)

    Eklof, S.L.

    1996-12-31

    Fuel cells are recognized as a versatile power generation option and accepted component of SMUD`s ART Program. SMUD has received wide support and recognition for promoting and implementing fuel cell power plants, as well as other innovative generation, based primarily on technological factors. Current economic and technical realities in the electric generation market highlight other important factors, such as the cost involved to develop a slate of such resources. The goal now is to develop only those select quality resources most likely to become commercially viable in the near future. The challenge becomes the identification of candidate technologies with the greatest potential, and then matching the technologies with the applications that will help to make them successful. Utility participation in this development is critical so as to provide the industry with case examples of advanced technologies that can be applied in a way beneficial to both the utility and its customers. The ART resource acquisitions provide the experience base upon which to guide this selection process, and should bring about the cost reductions and reliability improvements sought.

  12. Distributed generation: Early markets for emerging technologies

    SciTech Connect (OSTI)

    Lenssen, N.; Cler, G.

    1999-11-01

    How will developers of emerging distributed generation technologies successfully commercialize their products. This paper presents one approach for these developers, borrowing from the experience of other developers of innovative technologies and services. E Source`s analysis suggests, however, that there is already more of a market for distributed generation than is generally recognized. US and Canadian firms already buy about 3,400 megawatts of small generators each year, mostly for backup power but some as the primary power source for selected loads and facilities. This demand is expected to double in 10 years. The global market for small generators is already more than 10 times this size, at some 40,000 megawatts per year, and it is expected to continue growing rapidly, especially in developing nations. Just how the emerging distributed generation technologies, such as microturbines, fuel cells, and Stirling engines compete-or surpass-the conventional technologies will have a huge impact on their eventual commercial success.

  13. 2014-07-09 Issuance: Energy Conservation Standards for Computer and Battery Backup Systems; Notice of Public Meeting and Availability of Framework Document

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register notice of public meeting and availability of framework document for computer and battery backup systems, as issued by the Deputy Assistant Secretary for Energy Efficiency on July 9, 2014. Though it is not inteded or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

  14. 2010 Manufacturing Readiness Assessment Update to the 2008 Report for Fuel Cell Stacks and Systems for the Backup Power and Materials Handling Equipment Markets

    SciTech Connect (OSTI)

    Wheeler, D.; Ulsh, M.

    2012-08-01

    In 2008, the National Renewable Energy Laboratory (NREL), under contract to the US Department of Energy (DOE), conducted a manufacturing readiness assessment (MRA) of fuel cell systems and fuel cell stacks for back-up power and material handling applications (MHE). To facilitate the MRA, manufacturing readiness levels (MRL) were defined that were based on the Technology Readiness Levels previously established by the US Department of Energy (DOE). NREL assessed the extensive existing hierarchy of MRLs developed by Department of Defense (DoD) and other Federal entities, and developed a MRL scale adapted to the needs of the Fuel Cell Technologies Program (FCTP) and to the status of the fuel cell industry. The MRL ranking of a fuel cell manufacturing facility increases as the manufacturing capability transitions from laboratory prototype development through Low Rate Initial Production to Full Rate Production. DOE can use MRLs to address the economic and institutional risks associated with a ramp-up in polymer electrolyte membrane (PEM) fuel cell production. In 2010, NREL updated this assessment, including additional manufacturers, an assessment of market developments since the original report, and a comparison of MRLs between 2008 and 2010.

  15. (Performance evaluation of fabric bug filters on a bench-scale coal gasifier)

    SciTech Connect (OSTI)

    Not Available

    1986-04-15

    The objective of this proposed work is to demonstrate the operational and economic feasibility of using high-temperature ceramic filters for particulate control in a variety of coal gasification power generating systems.

  16. Metabolic engineering of microorganisms for biofuels production: from bugs to synthetic biology to fuels

    SciTech Connect (OSTI)

    Kuk Lee, Sung; Chou, Howard; Ham, Timothy S.; Soon Lee, Taek; Keasling, Jay D.

    2009-12-02

    The ability to generate microorganisms that can produce biofuels similar to petroleum-based transportation fuels would allow the use of existing engines and infrastructure and would save an enormous amount of capital required for replacing the current infrastructure to accommodate biofuels that have properties significantly different from petroleum-based fuels. Several groups have demonstrated the feasibility of manipulating microbes to produce molecules similar to petroleum-derived products, albeit at relatively low productivity (e.g. maximum butanol production is around 20 g/L). For cost-effective production of biofuels, the fuel-producing hosts and pathways must be engineered and optimized. Advances in metabolic engineering and synthetic biology will provide new tools for metabolic engineers to better understand how to rewire the cell in order to create the desired phenotypes for the production of economically viable biofuels.

  17. Generation Planning (pbl/generation)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Generation Hydro Power Wind Power Monthly GSP BPA White Book Dry Year Tools Firstgov Generation Planning Thumbnail image of BPA White Book BPA White Book (1998-2014) Draft Dry...

  18. Distributed Generation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and regulations such as IEEE (Institute of Electrical and Electronics Engineers) 1547 have come a long way in addressing interconnection standards for distributed generation, ...

  19. Problems and solutions for protective relay applications in petroleum facilities -- Some protection applications for generators and transformers

    SciTech Connect (OSTI)

    Dudor, J.S.; Padden, L.K.

    1995-12-31

    Two areas of medium and high voltage protective relaying for industry applications are addressed: (1) generator backup protection and (2) protection of transformers with relatively high values of available fault currents. The presentation is a series of cases that were studied on electrical power systems at different industry facilities. The first part of this paper discusses the use of voltage controlled or voltage restraint time-overcurrent (51V) relays and distance (21) relays applied as generator backup protection. Actual applications on bus-connected and unit-connected generators are presented with a discussion of the protective relay settings and problems encountered. The second part of this paper discusses the application of proper protective devices, including protective relays and instrument transformers to protect transformers installed on buses with relatively high available primary fault currents. Problems encountered with the instrument transformer and protective relay selection are addressed, including saturation, burden, and protection from failure. Emphasis is placed on routine and special applications, lessons learned on real projects, and trouble spots to avoid.

  20. Microsoft PowerPoint - 03.2010_Metering Billing MDM America.pptx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    METERING BILLING/MDM AMERICA Back-up Generation Sources (BUGS) Prepared by Steve Pullins March 9, 2010 Metering, Billing/MDM America - San Diego, CA This material is based upon work supported by the Department of Energy under Award Number DE- Department of Energy under Award Number DE AC26-04NT41817 This presentation was prepared as an account of work sponsored by an agency of This presentation was prepared as an account of work sponsored by an agency of the United States Government. Neither the

  1. Cray Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2013, version of the Cray CC++ manual at docs.cray.com, Chapter 10, "Using Predefined Macros":

    Macro

    <...

  2. GNU Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    GLADY CASSIT Y VANDALIA MURPHY CR EEK BU CKHN-CENT URY CLAY GLENVILLE N MINNORA JARVISVILLE FAR MINGTON PH ILIPPI BELIN GT ON WAYN ESBUR G PR UNT Y GLENVILLE S CAVE RUN TAYLOR DRAIN ROSEDALE ST MPT-N RMNT-SHK WESTON-JAN E LEW SWN DL-WID EN VADIS STANL EY DEKALB UNION TALLM AN SVILL E ASPINALL-FIN ST ER ZOLLARSVILLE WILBU R RAMSEY HEATER S BR IDGEPORT-PRUNT YTOWN ALEXAND ER LILLY FORK SH ERMAN HIRAM ST FK-BLST N CK BU RNS CH APEL S BR WN -LUM BER PORT CON INGS PR ATT BOSWELL REVEL ELK C REEK

  3. CAF Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Research | Department of Energy CAB-Comm Final Report Documents Accomplishments from Six Years of Algal Research CAB-Comm Final Report Documents Accomplishments from Six Years of Algal Research May 10, 2016 - 5:40pm Addthis The Consortium for Algal Biofuel Commercialization (CAB-Comm), led by the University of California, San Diego, has just released its final report, detailing the many accomplishments and impactful contributions achieved in its six years of operation. CAB-Comm was

  4. Intel Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    November 2013 Compiling with -ipo produces "unresolved" warning messages at link time on Cray systems November 18, 2013 by Mike Stewart, NERSC USG Status: Reported to the darshan developers

  5. Intel Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    4 C++11 header files appear missing on Edison December 3, 2014 by Scott French, NERSC USG Status: Reported to Cray (801693), Workaround available

  6. Intel Bug Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    5 Intel C++ compiler error: stl_iterator_base_types.h December 7, 2015 by Scott French Because the system-supplied version of GCC is relatively old (4.3.4) it is common practice to load the gcc module on our Cray systems when C++11 support is required under the Intel C++ compilers.

  7. PULSE GENERATOR

    DOE Patents [OSTI]

    Roeschke, C.W.

    1957-09-24

    An improvement in pulse generators is described by which there are produced pulses of a duration from about 1 to 10 microseconds with a truly flat top and extremely rapid rise and fall. The pulses are produced by triggering from a separate input or by modifying the current to operate as a free-running pulse generator. In its broad aspect, the disclosed pulse generator comprises a first tube with an anode capacitor and grid circuit which controls the firing; a second tube series connected in the cathode circuit of the first tube such that discharge of the first tube places a voltage across it as the leading edge of the desired pulse; and an integrator circuit from the plate across the grid of the second tube to control the discharge time of the second tube, determining the pulse length.

  8. Microwave generator

    DOE Patents [OSTI]

    Kwan, T.J.T.; Snell, C.M.

    1987-03-31

    A microwave generator is provided for generating microwaves substantially from virtual cathode oscillation. Electrons are emitted from a cathode and accelerated to an anode which is spaced apart from the cathode. The anode has an annular slit there through effective to form the virtual cathode. The anode is at least one range thickness relative to electrons reflecting from the virtual cathode. A magnet is provided to produce an optimum magnetic field having the field strength effective to form an annular beam from the emitted electrons in substantial alignment with the annular anode slit. The magnetic field, however, does permit the reflected electrons to axially diverge from the annular beam. The reflected electrons are absorbed by the anode in returning to the real cathode, such that substantially no reflexing electrons occur. The resulting microwaves are produced with a single dominant mode and are substantially monochromatic relative to conventional virtual cathode microwave generators. 6 figs.

  9. Online Monitoring Technical Basis and Analysis Framework for Emergency Diesel Generators - Interim Report for FY 2013

    SciTech Connect (OSTI)

    Binh T. Pham; Nancy J. Lybeck; Vivek Agarwal

    2012-12-01

    The Light Water Reactor Sustainability program at Idaho National Laboratory is actively conducting research to develop and demonstrate online monitoring capabilities for active components in existing nuclear power plants. Idaho National Laboratory and the Electric Power Research Institute are working jointly to implement a pilot project to apply these capabilities to emergency diesel generators and generator step-up transformers. The Electric Power Research Institute Fleet-Wide Prognostic and Health Management Software Suite will be used to implement monitoring in conjunction with utility partners: Braidwood Generating Station (owned by Exelon Corporation) for emergency diesel generators, and Shearon Harris Nuclear Generating Station (owned by Duke Energy Progress) for generator step-up transformers. This report presents monitoring techniques, fault signatures, and diagnostic and prognostic models for emergency diesel generators. Emergency diesel generators provide backup power to the nuclear power plant, allowing operation of essential equipment such as pumps in the emergency core coolant system during catastrophic events, including loss of offsite power. Technical experts from Braidwood are assisting Idaho National Laboratory and Electric Power Research Institute in identifying critical faults and defining fault signatures associated with each fault. The resulting diagnostic models will be implemented in the Fleet-Wide Prognostic and Health Management Software Suite and tested using data from Braidwood. Parallel research on generator step-up transformers was summarized in an interim report during the fourth quarter of fiscal year 2012.

  10. Magnetocumulative generator

    DOE Patents [OSTI]

    Pettibone, J.S.; Wheeler, P.C.

    1981-06-08

    An improved magnetocumulative generator is described that is useful for producing magnetic fields of very high energy content over large spatial volumes. The polar directed pleated magnetocumulative generator has a housing providing a housing chamber with an electrically conducting surface. The chamber forms a coaxial system having a small radius portion and a large radius portion. When a magnetic field is injected into the chamber, from an external source, most of the magnetic flux associated therewith positions itself in the small radius portion. The propagation of an explosive detonation through high-explosive layers disposed adjacent to the housing causes a phased closure of the chamber which sweeps most of the magnetic flux into the large radius portion of the coaxial system. The energy content of the magnetic field is greatly increased by flux stretching as well as by flux compression. The energy enhanced magnetic field is utilized within the housing chamber itself.

  11. PLASMA GENERATOR

    DOE Patents [OSTI]

    Foster, J.S. Jr.

    1958-03-11

    This patent describes apparatus for producing an electricity neutral ionized gas discharge, termed a plasma, substantially free from contamination with neutral gas particles. The plasma generator of the present invention comprises a plasma chamber wherein gas introduced into the chamber is ionized by a radiofrequency source. A magnetic field is used to focus the plasma in line with an exit. This magnetic field cooperates with a differential pressure created across the exit to draw a uniform and uncontaminated plasma from the plasma chamber.

  12. Thermoelectric generator

    DOE Patents [OSTI]

    Pryslak, N.E.

    1974-02-26

    A thermoelectric generator having a rigid coupling or stack'' between the heat source and the hot strap joining the thermoelements is described. The stack includes a member of an insulating material, such as ceramic, for electrically isolating the thermoelements from the heat source, and a pair of members of a ductile material, such as gold, one each on each side of the insulating member, to absorb thermal differential expansion stresses in the stack. (Official Gazette)

  13. Cluster generator

    DOE Patents [OSTI]

    Donchev, Todor I.; Petrov, Ivan G.

    2011-05-31

    Described herein is an apparatus and a method for producing atom clusters based on a gas discharge within a hollow cathode. The hollow cathode includes one or more walls. The one or more walls define a sputtering chamber within the hollow cathode and include a material to be sputtered. A hollow anode is positioned at an end of the sputtering chamber, and atom clusters are formed when a gas discharge is generated between the hollow anode and the hollow cathode.

  14. Photon generator

    DOE Patents [OSTI]

    Srinivasan-Rao, Triveni

    2002-01-01

    A photon generator includes an electron gun for emitting an electron beam, a laser for emitting a laser beam, and an interaction ring wherein the laser beam repetitively collides with the electron beam for emitting a high energy photon beam therefrom in the exemplary form of x-rays. The interaction ring is a closed loop, sized and configured for circulating the electron beam with a period substantially equal to the period of the laser beam pulses for effecting repetitive collisions.

  15. Electric generator

    DOE Patents [OSTI]

    Foster, Jr., John S.; Wilson, James R.; McDonald, Jr., Charles A.

    1983-01-01

    1. In an electrical energy generator, the combination comprising a first elongated annular electrical current conductor having at least one bare surface extending longitudinally and facing radially inwards therein, a second elongated annular electrical current conductor disposed coaxially within said first conductor and having an outer bare surface area extending longitudinally and facing said bare surface of said first conductor, the contiguous coaxial areas of said first and second conductors defining an inductive element, means for applying an electrical current to at least one of said conductors for generating a magnetic field encompassing said inductive element, and explosive charge means disposed concentrically with respect to said conductors including at least the area of said inductive element, said explosive charge means including means disposed to initiate an explosive wave front in said explosive advancing longitudinally along said inductive element, said wave front being effective to progressively deform at least one of said conductors to bring said bare surfaces thereof into electrically conductive contact to progressively reduce the inductance of the inductive element defined by said conductors and transferring explosive energy to said magnetic field effective to generate an electrical potential between undeformed portions of said conductors ahead of said explosive wave front.

  16. Monthly Generation System Peak (pbl/generation)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Generation > Generation Hydro Power Wind Power Monthly GSP BPA White Book Dry Year Tools Firstgov Monthly Generation System Peak (GSP) This site is no longer maintained. Page last...

  17. Magnetocumulative generator

    DOE Patents [OSTI]

    Pettibone, Joseph S.; Wheeler, Paul C.

    1983-01-01

    An improved magnetocumulative generator is described that is useful for producing magnetic fields of very high energy content over large spatial volumes. The polar directed pleated magnetocumulative generator has a housing (100, 101, 102, 103, 104, 105) providing a housing chamber (106) with an electrically conducting surface. The chamber (106) forms a coaxial system having a small radius portion and a large radius portion. When a magnetic field is injected into the chamber (106), from an external source, most of the magnetic flux associated therewith positions itself in the small radius portion. The propagation of an explosive detonation through high-explosive layers (107, 108) disposed adjacent to the housing causes a phased closure of the chamber (106) which sweeps most of the magnetic flux into the large radius portion of the coaxial system. The energy content of the magnetic field is greatly increased by flux stretching as well as by flux compression. The energy enhanced magnetic field is utilized within the housing chamber itself.

  18. PLASMA GENERATOR

    DOE Patents [OSTI]

    Wilcox, J.M.; Baker, W.R.

    1963-09-17

    This invention is a magnetohydrodynamic device for generating a highly ionized ion-electron plasma at a region remote from electrodes and structural members, thus avoiding contamination of the plasma. The apparatus utilizes a closed, gas-filled, cylindrical housing in which an axially directed magnetic field is provided. At one end of the housing, a short cylindrical electrode is disposed coaxially around a short axial inner electrode. A radial electrical discharge is caused to occur between the inner and outer electrodes, creating a rotating hydromagnetic ionization wave that propagates aiong the magnetic field lines toward the opposite end of the housing. A shorting switch connected between the electrodes prevents the wave from striking the opposite end of the housing. (AEC)

  19. Triboelectric generator

    DOE Patents [OSTI]

    Wang, Zhong L; Fan, Fengru; Lin, Long; Zhu, Guang; Pan, Caofeng; Zhou, Yusheng

    2015-11-03

    A generator includes a thin first contact charging layer and a thin second contact charging layer. The thin first contact charging layer includes a first material that has a first rating on a triboelectric series. The thin first contact charging layer has a first side with a first conductive electrode applied thereto and an opposite second side. The thin second contact charging layer includes a second material that has a second rating on a triboelectric series that is more negative than the first rating. The thin first contact charging layer has a first side with a first conductive electrode applied thereto and an opposite second side. The thin second contact charging layer is disposed adjacent to the first contact charging layer so that the second side of the second contact charging layer is in contact with the second side of the first contact charging layer.

  20. Fuel Cell Comparison of Distributed Power Generation Technologies

    Office of Energy Efficiency and Renewable Energy (EERE)

    This report examines backup power and prime power systems and addresses the potential energy and environmental effects of substituting fuel cells for existing combustion technologies based on microturbines and internal combustion engines.

    1. Fuel Cycle Comparison of Distributed Power Generation Technologies

      Office of Energy Efficiency and Renewable Energy (EERE)

      This report examines backup power and prime power systems and addresses the potential energy and environmental effects of substituting fuel cells for existing combustion technologies based on microturbines and internal combustion engines.

    2. Business Owners: Respond to an Energy Emergency | Department...

      Broader source: Energy.gov (indexed) [DOE]

      Decide whether to activate backup power-If your backup generator doesn't automatically turn on during a power outage, you'll have to determine when to activate backup systems. ...

    3. Nurbs and grid generation

      SciTech Connect (OSTI)

      Barnhill, R.E.; Farin, G.; Hamann, B.

      1995-12-31

      This paper provides a basic overview of NURBS and their application to numerical grid generation. Curve/surface smoothing, accelerated grid generation, and the use of NURBS in a practical grid generation system are discussed.

    4. Hydrogen Generator Appliance

      Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

      J slide presentation: hydrogen Generator appliance Gus Block, Nuvera Fuel Cells

    5. Gamma ray generator

      DOE Patents [OSTI]

      Firestone, Richard B; Reijonen, Jani

      2014-05-27

      An embodiment of a gamma ray generator includes a neutron generator and a moderator. The moderator is coupled to the neutron generator. The moderator includes a neutron capture material. In operation, the neutron generator produces neutrons and the neutron capture material captures at least some of the neutrons to produces gamma rays. An application of the gamma ray generator is as a source of gamma rays for calibration of gamma ray detectors.

    6. Bugs, Microbes, Biofuels, and Coffee

      SciTech Connect (OSTI)

      Ceja-Navarro, Javier A.

      2015-07-14

      ​​Berkeley Lab scientist Javier A. Ceja-Navarro discusses how his team is learning to utilize microbes that live inside the digestive tracts of insects for pest control, improved agriculture, and energy production.

    7. OpenEI Community - bug

      Open Energy Info (EERE)

      Ghost" entries http:en.openei.orgcommunitydiscussionghost-entries

      There is an issue that Illinois State University has come across. From Nick B:

    8. Cylindrical neutron generator

      DOE Patents [OSTI]

      Leung, Ka-Ngo

      2005-06-14

      A cylindrical neutron generator is formed with a coaxial RF-driven plasma ion source and target. A deuterium (or deuterium and tritium) plasma is produced by RF excitation in a cylindrical plasma ion generator using an RF antenna. A cylindrical neutron generating target is coaxial with the ion generator, separated by plasma and extraction electrodes which contain many slots. The plasma generator emanates ions radially over 360.degree. and the cylindrical target is thus irradiated by ions over its entire circumference. The plasma generator and target may be as long as desired. The plasma generator may be in the center and the neutron target on the outside, or the plasma generator may be on the outside and the target on the inside. In a nested configuration, several concentric targets and plasma generating regions are nested to increase the neutron flux.

    9. Cylindrical neutron generator

      DOE Patents [OSTI]

      Leung, Ka-Ngo

      2008-04-22

      A cylindrical neutron generator is formed with a coaxial RF-driven plasma ion source and target. A deuterium (or deuterium and tritium) plasma is produced by RF excitation in a cylindrical plasma ion generator using an RF antenna. A cylindrical neutron generating target is coaxial with the ion generator, separated by plasma and extraction electrodes which contain many slots. The plasma generator emanates ions radially over 360.degree. and the cylindrical target is thus irradiated by ions over its entire circumference. The plasma generator and target may be as long as desired. The plasma generator may be in the center and the neutron target on the outside, or the plasma generator may be on the outside and the target on the inside. In a nested configuration, several concentric targets and plasma generating regions are nested to increase the neutron flux.

    10. Cylindrical neutron generator

      DOE Patents [OSTI]

      Leung, Ka-Ngo

      2009-12-29

      A cylindrical neutron generator is formed with a coaxial RF-driven plasma ion source and target. A deuterium (or deuterium and tritium) plasma is produced by RF excitation in a cylindrical plasma ion generator using an RF antenna. A cylindrical neutron generating target is coaxial with the ion generator, separated by plasma and extraction electrodes which contain many slots. The plasma generator emanates ions radially over 360.degree. and the cylindrical target is thus irradiated by ions over its entire circumference. The plasma generator and target may be as long as desired. The plasma generator may be in the center and the neutron target on the outside, or the plasma generator may be on the outside and the target on the inside. In a nested configuration, several concentric targets and plasma generating regions are nested to increase the neutron flux.

    11. Power Generation for River and Tidal Generators

      Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

      Power Generation for River and Tidal Generators Eduard Muljadi, Alan Wright, and Vahan Gevorgian National Renewable Energy Laboratory James Donegan, Cian Marnagh, and Jarlath McEntee Ocean Renewable Power Company Technical Report NREL/TP-5D00-66097 June 2016 NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Operated by the Alliance for Sustainable Energy, LLC This report is available at no cost from the National Renewable Energy

    12. Sustainable solar thermal power generation (STPG) technologies in Indian context

      SciTech Connect (OSTI)

      Sharma, R.S.

      1996-12-31

      India is a fast developing country. Some of the factors like population growth, industrialization, liberalization in economic policies, green revolution and awareness toward the environment, are increasing the electricity demand rapidly. As per the 14th Power Survey Report, an energy deficit of (+) 9% and peak demand deficit of (+) 18% have been estimated. Keeping in view the liberalization in economic policies, this deficit may be higher by the year 2000 AD. An estimation indicates that India is blessed with solar energy to the tune of 5 x 10{sup 15} kWh/yr. Being clean and inexhaustible source of energy, it can be used for large-scale power generation in the country. Keeping in view the present state-of-art technologies for STPG in MW range, best possible efforts are required to be made by all the concerned, to develop sustainable STPG technology of the future, specially for tropical regions. Standardization of vital equipment is an important aspect. There are a few required criteria like simple and robust technology, its transfer and adaptation in tropical climate conditions; high plant load factor without fossil-fired backup; availability of plant during evening peak and night hours; least use of fragile components, and capacity optimization for MW plants as per solar irradiance and environmental factors. In this paper, efforts have been made to compare the different STPG technologies. On the basis, of literature surveyed and studies carried out by the author, it may be stated that Central Receiver System technologies using molten salt and volumetric air receiver, along with molten salt and ceramic thermal storage respectively seems to be suitable and comparable in Indian context. Performance of SOLAR-TWO and PHOEBUS plants may be decisive.

    13. Underwater power generator

      SciTech Connect (OSTI)

      Bowley, W.W.

      1983-05-10

      Apparatus and method for generating electrical power by disposing a plurality of power producing modules in a substantially constant velocity ocean current and mechanically coupling the output of the modules to drive a single electrical generator is disclosed.

    14. Quantum random number generator

      DOE Patents [OSTI]

      Pooser, Raphael C.

      2016-05-10

      A quantum random number generator (QRNG) and a photon generator for a QRNG are provided. The photon generator may be operated in a spontaneous mode below a lasing threshold to emit photons. Photons emitted from the photon generator may have at least one random characteristic, which may be monitored by the QRNG to generate a random number. In one embodiment, the photon generator may include a photon emitter and an amplifier coupled to the photon emitter. The amplifier may enable the photon generator to be used in the QRNG without introducing significant bias in the random number and may enable multiplexing of multiple random numbers. The amplifier may also desensitize the photon generator to fluctuations in power supplied thereto while operating in the spontaneous mode. In one embodiment, the photon emitter and amplifier may be a tapered diode amplifier.

    15. Motor/generator

      DOE Patents [OSTI]

      Hickam, Christopher Dale

      2008-05-13

      A motor/generator is provided for connecting between a transmission input shaft and an output shaft of a prime mover. The motor/generator may include a motor/generator housing, a stator mounted to the motor/generator housing, a rotor mounted at least partially within the motor/generator housing and rotatable about a rotor rotation axis, and a transmission-shaft coupler drivingly coupled to the rotor. The transmission-shaft coupler may include a clamp, which may include a base attached to the rotor and a plurality of adjustable jaws.

    16. Solar thermoelectric generator

      DOE Patents [OSTI]

      Toberer, Eric S.; Baranowski, Lauryn L.; Warren, Emily L.

      2016-05-03

      Solar thermoelectric generators (STEGs) are solid state heat engines that generate electricity from concentrated sunlight. A novel detailed balance model for STEGs is provided and applied to both state-of-the-art and idealized materials. STEGs can produce electricity by using sunlight to heat one side of a thermoelectric generator. While concentrated sunlight can be used to achieve extremely high temperatures (and thus improved generator efficiency), the solar absorber also emits a significant amount of black body radiation. This emitted light is the dominant loss mechanism in these generators. In this invention, we propose a solution to this problem that eliminates virtually all of the emitted black body radiation. This enables solar thermoelectric generators to operate at higher efficiency and achieve said efficient with lower levels of optical concentration. The solution is suitable for both single and dual axis solar thermoelectric generators.

    17. Quantum random number generation

      DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

      Ma, Xiongfeng; Yuan, Xiao; Cao, Zhu; Zhang, Zhen; Qi, Bing

      2016-06-28

      Here, quantum physics can be exploited to generate true random numbers, which play important roles in many applications, especially in cryptography. Genuine randomness from the measurement of a quantum system reveals the inherent nature of quantumness -- coherence, an important feature that differentiates quantum mechanics from classical physics. The generation of genuine randomness is generally considered impossible with only classical means. Based on the degree of trustworthiness on devices, quantum random number generators (QRNGs) can be grouped into three categories. The first category, practical QRNG, is built on fully trusted and calibrated devices and typically can generate randomness at amore » high speed by properly modeling the devices. The second category is self-testing QRNG, where verifiable randomness can be generated without trusting the actual implementation. The third category, semi-self-testing QRNG, is an intermediate category which provides a tradeoff between the trustworthiness on the device and the random number generation speed.« less

    18. Steam generator support system

      DOE Patents [OSTI]

      Moldenhauer, James E.

      1987-01-01

      A support system for connection to an outer surface of a J-shaped steam generator for use with a nuclear reactor or other liquid metal cooled power source. The J-shaped steam generator is mounted with the bent portion at the bottom. An arrangement of elongated rod members provides both horizontal and vertical support for the steam generator. The rod members are interconnected to the steam generator assembly and a support structure in a manner which provides for thermal distortion of the steam generator without the transfer of bending moments to the support structure and in a like manner substantially minimizes forces being transferred between the support structure and the steam generator as a result of seismic disturbances.

    19. Steam generator support system

      DOE Patents [OSTI]

      Moldenhauer, J.E.

      1987-08-25

      A support system for connection to an outer surface of a J-shaped steam generator for use with a nuclear reactor or other liquid metal cooled power source is disclosed. The J-shaped steam generator is mounted with the bent portion at the bottom. An arrangement of elongated rod members provides both horizontal and vertical support for the steam generator. The rod members are interconnected to the steam generator assembly and a support structure in a manner which provides for thermal distortion of the steam generator without the transfer of bending moments to the support structure and in a like manner substantially minimizes forces being transferred between the support structure and the steam generator as a result of seismic disturbances. 4 figs.

    20. Method of grid generation

      DOE Patents [OSTI]

      Barnette, Daniel W.

      2002-01-01

      The present invention provides a method of grid generation that uses the geometry of the problem space and the governing relations to generate a grid. The method can generate a grid with minimized discretization errors, and with minimal user interaction. The method of the present invention comprises assigning grid cell locations so that, when the governing relations are discretized using the grid, at least some of the discretization errors are substantially zero. Conventional grid generation is driven by the problem space geometry; grid generation according to the present invention is driven by problem space geometry and by governing relations. The present invention accordingly can provide two significant benefits: more efficient and accurate modeling since discretization errors are minimized, and reduced cost grid generation since less human interaction is required.

    1. Distributed generation systems model

      SciTech Connect (OSTI)

      Barklund, C.R.

      1994-12-31

      A slide presentation is given on a distributed generation systems model developed at the Idaho National Engineering Laboratory, and its application to a situation within the Idaho Power Company`s service territory. The objectives of the work were to develop a screening model for distributed generation alternatives, to develop a better understanding of distributed generation as a utility resource, and to further INEL`s understanding of utility concerns in implementing technological change.

    2. Generation | Department of Energy

      Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

      Generation Generation Southeastern’s Power Operations employees perform the tasks of declaring, scheduling, dispatching, and accounting for capacity and energy generated at the 22 hydroelectric projects in the agency’s 11-state marketing area. Southeastern has Certified System Operators, meeting the criteria set forth by the North American Electric Reliability Corporation. Southeastern's Power Operations employees perform the tasks of declaring, scheduling, dispatching, and accounting

    3. Distributed generation hits market

      SciTech Connect (OSTI)

      1997-10-01

      The pace at which vendors are developing and marketing gas turbines and reciprocating engines for small-scale applications may signal the widespread growth of distributed generation. Loosely defined to refer to applications in which power generation equipment is located close to end users who have near-term power capacity needs, distributed generation encompasses a broad range of technologies and load requirements. Disagreement is inevitable, but many industry observers associate distributed generation with applications anywhere from 25 kW to 25 MW. Ten years ago, distributed generation users only represented about 2% of the world market. Today, that figure has increased to about 4 or 5%, and probably could settle in the 20% range within a 3-to-5-year period, according to Michael Jones, San Diego, Calif.-based Solar Turbines Inc. power generation marketing manager. The US Energy Information Administration predicts about 175 GW of generation capacity will be added domestically by 2010. If 20% comes from smaller plants, distributed generation could account for about 35 GW. Even with more competition, it`s highly unlikely distributed generation will totally replace current market structures and central stations. Distributed generation may be best suited for making market inroads when and where central systems need upgrading, and should prove its worth when the system can`t handle peak demands. Typical applications include small reciprocating engine generators at remote customer sites or larger gas turbines to boost the grid. Additional market opportunities include standby capacity, peak shaving, power quality, cogeneration and capacity rental for immediate demand requirements. Integration of distributed generation systems--using gas-fueled engines, gas-fired combustion engines and fuel cells--can upgrade power quality for customers and reduce operating costs for electric utilities.

    4. Biomass: Biogas Generator

      Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

      BIOGAS GENERATOR Curriculum: Biomass Power (organic chemistry, chemicalcarbon cycles, plants, energy resourcestransformations) Grade Level: Middle School (6-8) Small groups (3 to ...

    5. Isolated trigger pulse generator

      DOE Patents [OSTI]

      Aaland, Kristian (Livermore, CA) [Livermore, CA

      1980-02-19

      A trigger pulse generation system capable of delivering a multiplicity of isolated 100 kV trigger pulses with picosecond simultaneity.

    6. Renewable Electricity Generation

      SciTech Connect (OSTI)

      2012-09-01

      This document highlights DOE's Office of Energy Efficiency and Renewable Energy's advancements in renewable electricity generation technologies including solar, water, wind, and geothermal.

    7. Talkin Bout Wind Generation

      Office of Energy Efficiency and Renewable Energy (EERE)

      The amount of electricity generated by the wind industry started to grow back around 1999, and since 2007 has been increasing at a rapid pace.

    8. Isolated trigger pulse generator

      DOE Patents [OSTI]

      Aaland, K.

      1980-02-19

      A trigger pulse generation system capable of delivering a multiplicity of isolated 100 kV trigger pulses with picosecond simultaneity. 2 figs.

    9. SNE TRAFIC GENERATOR

      Energy Science and Technology Software Center (OSTI)

      003027MLTPL00 Network Traffic Generator for Low-rate Small Network Equipment Software http://eln.lbl.gov/sne_traffic_gen.html

    10. Thermophotovoltaic energy generation

      DOE Patents [OSTI]

      Celanovic, Ivan; Chan, Walker; Bermel, Peter; Yeng, Adrian Y. X.; Marton, Christopher; Ghebrebrhan, Michael; Araghchini, Mohammad; Jensen, Klavs F.; Soljacic, Marin; Joannopoulos, John D.; Johnson, Steven G.; Pilawa-Podgurski, Robert; Fisher, Peter

      2015-08-25

      Inventive systems and methods for the generation of energy using thermophotovoltaic cells are described. Also described are systems and methods for selectively emitting electromagnetic radiation from an emitter for use in thermophotovoltaic energy generation systems. In at least some of the inventive energy generation systems and methods, a voltage applied to the thermophotovoltaic cell (e.g., to enhance the power produced by the cell) can be adjusted to enhance system performance. Certain embodiments of the systems and methods described herein can be used to generate energy relatively efficiently.

    11. NEGATIVE GATE GENERATOR

      DOE Patents [OSTI]

      Jones, C.S.; Eaton, T.E.

      1958-02-01

      This patent relates to pulse generating circuits and more particularly to rectangular pulse generators. The pulse generator of the present invention incorporates thyratrons as switching elements to discharge a first capacitor through a load resistor to initiate and provide the body of a Pulse, and subsequently dlscharge a second capacitor to impress the potential of its charge, with opposite potential polarity across the load resistor to terminate the pulse. Accurate rectangular pulses in the millimicrosecond range are produced across a low impedance by this generator.

    12. [Performance evaluation of fabric bug filters on a bench-scale coal gasifier]. Quarterly technical progress report, December 30, 1985--March 30, 1986

      SciTech Connect (OSTI)

      Not Available

      1986-04-15

      The objective of this proposed work is to demonstrate the operational and economic feasibility of using high-temperature ceramic filters for particulate control in a variety of coal gasification power generating systems.

    13. Solid aerosol generator

      DOE Patents [OSTI]

      Prescott, Donald S.; Schober, Robert K.; Beller, John

      1992-01-01

      An improved solid aerosol generator used to produce a gas borne stream of dry, solid particles of predetermined size and concentration. The improved solid aerosol generator nebulizes a feed solution of known concentration with a flow of preheated gas and dries the resultant wet heated aerosol in a grounded, conical heating chamber, achieving high recovery and flow rates.

    14. Improved solid aerosol generator

      DOE Patents [OSTI]

      Prescott, D.S.; Schober, R.K.; Beller, J.

      1988-07-19

      An improved solid aerosol generator used to produce a gas borne stream of dry, solid particles of predetermined size and concentration. The improved solid aerosol generator nebulizes a feed solution of known concentration with a flow of preheated gas and dries the resultant wet heated aerosol in a grounded, conical heating chamber, achieving high recovery and flow rates. 2 figs.

    15. Solid aerosol generator

      DOE Patents [OSTI]

      Prescott, D.S.; Schober, R.K.; Beller, J.

      1992-03-17

      An improved solid aerosol generator used to produce a gas borne stream of dry, solid particles of predetermined size and concentration is disclosed. The improved solid aerosol generator nebulizes a feed solution of known concentration with a flow of preheated gas and dries the resultant wet heated aerosol in a grounded, conical heating chamber, achieving high recovery and flow rates. 2 figs.

    16. Laser beam generating apparatus

      DOE Patents [OSTI]

      Warner, Bruce E. (Livermore, CA); Duncan, David B. (Auburn, CA)

      1994-01-01

      Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect).

    17. Laser beam generating apparatus

      DOE Patents [OSTI]

      Warner, Bruce E. (Livermore, CA); Duncan, David B. (Auburn, CA)

      1993-01-01

      Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect).

    18. Internal split field generator

      DOE Patents [OSTI]

      Thundat; Thomas George; Van Neste, Charles W.; Vass, Arpad Alexander

      2012-01-03

      A generator includes a coil of conductive material. A stationary magnetic field source applies a stationary magnetic field to the coil. An internal magnetic field source is disposed within a cavity of the coil to apply a moving magnetic field to the coil. The stationary magnetic field interacts with the moving magnetic field to generate an electrical energy in the coil.

    19. Laser beam generating apparatus

      DOE Patents [OSTI]

      Warner, B.E.; Duncan, D.B.

      1994-02-15

      Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus is described. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect). 7 figures.

    20. Laser beam generating apparatus

      DOE Patents [OSTI]

      Warner, B.E.; Duncan, D.B.

      1993-12-28

      Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect). 11 figures.

    1. Fuel cells provide a revenue-generating solution to power quality problems

      SciTech Connect (OSTI)

      King, J.M. Jr.

      1996-03-01

      Electric power quality and reliability are becoming increasingly important as computers and microprocessors assume a larger role in commercial, health care and industrial buildings and processes. At the same time, constraints on transmission and distribution of power from central stations are making local areas vulnerable to low voltage, load addition limitations, power quality and power reliability problems. Many customers currently utilize some form of premium power in the form of standby generators and/or UPS systems. These include customers where continuous power is required because of health and safety or security reasons (hospitals, nursing homes, places of public assembly, air traffic control, military installations, telecommunications, etc.) These also include customers with industrial or commercial processes which can`t tolerance an interruption of power because of product loss or equipment damage. The paper discusses the use of the PC25 fuel cell power plant for backup and parallel power supplies for critical industrial applications. Several PC25 installations are described: the use of propane in a PC25; the use by rural cooperatives; and a demonstration of PC25 technology using landfill gas.

    2. Final environmental impact statement. Management of commercially generated radioactive waste. Volume 2. Appendices

      SciTech Connect (OSTI)

      Not Available

      1980-10-01

      This EIS analyzes the significant environmental impacts that could occur if various technologies for management and disposal of high-level and transuranic wastes from commercial nuclear power reactors were to be developed and implemented. This EIS will serve as the environmental input for the decision on which technology, or technologies, will be emphasized in further research and development activities in the commercial waste management program. The action proposed in this EIS is to (1) adopt a national strategy to develop mined geologic repositories for disposal of commercially generated high-level and transuranic radioactive waste (while continuing to examine subseabed and very deep hole disposal as potential backup technologies) and (2) conduct a R and D program to develop such facilities and the necessary technology to ensure the safe long-term containment and isolation of these wastes. The Department has considered in this statement: development of conventionally mined deep geologic repositories for disposal of spent fuel from nuclear power reactors and/or radioactive fuel reprocessing wastes; balanced development of several alternative disposal methods; and no waste disposal action. This volume contains appendices of supplementary data on waste management systems, geologic disposal, radiological standards, radiation dose calculation models, related health effects, baseline ecology, socio-economic conditions, hazard indices, comparison of defense and commercial wastes, design considerations, and wastes from thorium-based fuel cycle alternatives. (DMC)

    3. Geothermal Generation | Open Energy Information

      Open Energy Info (EERE)

      Geothermal Generation This article is a stub. You can help OpenEI by expanding it. Global Geothermal Energy Generation Global Geothermal Electricity Generation in 2007 (in millions...

    4. Compact neutron generator

      DOE Patents [OSTI]

      Leung, Ka-Ngo; Lou, Tak Pui

      2005-03-22

      A compact neutron generator has at its outer circumference a toroidal shaped plasma chamber in which a tritium (or other) plasma is generated. A RF antenna is wrapped around the plasma chamber. A plurality of tritium ion beamlets are extracted through spaced extraction apertures of a plasma electrode on the inner surface of the toroidal plasma chamber and directed inwardly toward the center of neutron generator. The beamlets pass through spaced acceleration and focusing electrodes to a neutron generating target at the center of neutron generator. The target is typically made of titanium tubing. Water is flowed through the tubing for cooling. The beam can be pulsed rapidly to achieve ultrashort neutron bursts. The target may be moved rapidly up and down so that the average power deposited on the surface of the target may be kept at a reasonable level. The neutron generator can produce fast neutrons from a T-T reaction which can be used for luggage and cargo interrogation applications. A luggage or cargo inspection system has a pulsed T-T neutron generator or source at the center, surrounded by associated gamma detectors and other components for identifying explosives or other contraband.

    5. Synthetic guide star generation

      DOE Patents [OSTI]

      Payne, Stephen A.; Page, Ralph H.; Ebbers, Christopher A.; Beach, Raymond J.

      2004-03-09

      A system for assisting in observing a celestial object and providing synthetic guide star generation. A lasing system provides radiation at a frequency at or near 938 nm and radiation at a frequency at or near 1583 nm. The lasing system includes a fiber laser operating between 880 nm and 960 nm and a fiber laser operating between 1524 nm and 1650 nm. A frequency-conversion system mixes the radiation and generates light at a frequency at or near 589 nm. A system directs the light at a frequency at or near 589 nm toward the celestial object and provides synthetic guide star generation.

    6. Magnetic field generator

      DOE Patents [OSTI]

      Krienin, Frank (Shoreham, NY)

      1990-01-01

      A magnetic field generating device provides a useful magnetic field within a specific retgion, while keeping nearby surrounding regions virtually field free. By placing an appropriate current density along a flux line of the source, the stray field effects of the generator may be contained. One current carrying structure may support a truncated cosine distribution, and it may be surrounded by a current structure which follows a flux line that would occur in a full coaxial double cosine distribution. Strong magnetic fields may be generated and contained using superconducting cables to approximate required current surfaces.

    7. Synthetic guide star generation

      SciTech Connect (OSTI)

      Payne, Stephen A; Page, Ralph H; Ebbers, Christopher A; Beach, Raymond J

      2008-06-10

      A system for assisting in observing a celestial object and providing synthetic guide star generation. A lasing system provides radiation at a frequency at or near 938 nm and radiation at a frequency at or near 1583 nm. The lasing system includes a fiber laser operating between 880 nm and 960 nm and a fiber laser operating between 1524 nm and 1650 nm. A frequency-conversion system mixes the radiation and generates light at a frequency at or near 589 nm. A system directs the light at a frequency at or near 589 nm toward the celestial object and provides synthetic guide star generation.

    8. PULSE SYNTHESIZING GENERATOR

      DOE Patents [OSTI]

      Kerns, Q.A.

      1963-08-01

      >An electronlc circuit for synthesizing electrical current pulses having very fast rise times includes several sinewave generators tuned to progressively higher harmonic frequencies with signal amplitudes and phases selectable according to the Fourier series of the waveform that is to be synthesized. Phase control is provided by periodically triggering the generators at precisely controlled times. The outputs of the generators are combined in a coaxial transmission line. Any frequency-dependent delays that occur in the transmission line can be readily compensated for so that the desired signal wave shape is obtained at the output of the line. (AEC)

    9. Mann 3600 Pattern Generator

      Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

      Mann 3600 Pattern Generator Description: The GCA Mann 3600 pattern generator is designed for patterning standard 5" x 5" mask plates for use in optical lithography. Pattern designs are created in AutoCAD. The AutoCAD file is then converted into binary format, which can be fractured into data read by the pattern generator. The illumination source for exposures is a high pressure Hg arc lamp. The light is filtered and projected onto a shutter, which controls the exposure dose. A set of

    10. Graph Generator Survey

      SciTech Connect (OSTI)

      Lothian, Josh; Powers, Sarah S; Sullivan, Blair D; Baker, Matthew B; Schrock, Jonathan; Poole, Stephen W

      2013-12-01

      The benchmarking effort within the Extreme Scale Systems Center at Oak Ridge National Laboratory seeks to provide High Performance Computing benchmarks and test suites of interest to the DoD sponsor. The work described in this report is a part of the effort focusing on graph generation. A previously developed benchmark, SystemBurn, allowed the emulation of dierent application behavior profiles within a single framework. To complement this effort, similar capabilities are desired for graph-centric problems. This report examines existing synthetic graph generator implementations in preparation for further study on the properties of their generated synthetic graphs.

    11. Relativistic electron beam generator

      DOE Patents [OSTI]

      Mooney, L.J.; Hyatt, H.M.

      1975-11-11

      A relativistic electron beam generator for laser media excitation is described. The device employs a diode type relativistic electron beam source having a cathode shape which provides a rectangular output beam with uniform current density.

    12. Vector generator scan converter

      DOE Patents [OSTI]

      Moore, J.M.; Leighton, J.F.

      1988-02-05

      High printing speeds for graphics data are achieved with a laser printer by transmitting compressed graphics data from a main processor over an I/O channel to a vector generator scan converter which reconstructs a full graphics image for input to the laser printer through a raster data input port. The vector generator scan converter includes a microprocessor with associated microcode memory containing a microcode instruction set, a working memory for storing compressed data, vector generator hardware for drawing a full graphic image from vector parameters calculated by the microprocessor, image buffer memory for storing the reconstructed graphics image and an output scanner for reading the graphics image data and inputting the data to the printer. The vector generator scan converter eliminates the bottleneck created by the I/O channel for transmitting graphics data from the main processor to the laser printer, and increases printer speed up to thirty fold. 7 figs.

    13. Denison Dam Historical Generation

      Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

      50,000 100,000 150,000 200,000 250,000 300,000 350,000 400,000 450,000 500,000 (MWh) Denison Dam Historical Generation

    14. Scram signal generator

      DOE Patents [OSTI]

      Johanson, Edward W.; Simms, Richard

      1981-01-01

      A scram signal generating circuit for nuclear reactor installations monitors a flow signal representing the flow rate of the liquid sodium coolant which is circulated through the reactor, and initiates reactor shutdown for a rapid variation in the flow signal, indicative of fuel motion. The scram signal generating circuit includes a long-term drift compensation circuit which processes the flow signal and generates an output signal representing the flow rate of the coolant. The output signal remains substantially unchanged for small variations in the flow signal, attributable to long term drift in the flow rate, but a rapid change in the flow signal, indicative of a fast flow variation, causes a corresponding change in the output signal. A comparator circuit compares the output signal with a reference signal, representing a given percentage of the steady state flow rate of the coolant, and generates a scram signal to initiate reactor shutdown when the output signal equals the reference signal.

    15. Scram signal generator

      DOE Patents [OSTI]

      Johanson, E.W.; Simms, R.

      A scram signal generating circuit for nuclear reactor installations monitors a flow signal representing the flow rate of the liquid sodium coolant which is circulated through the reactor, and initiates reactor shutdown for a rapid variation in the flow signal, indicative of fuel motion. The scram signal generating circuit includes a long-term drift compensation circuit which processes the flow signal and generates an output signal representing the flow rate of the coolant. The output signal remains substantially unchanged for small variations in the flow signal, attributable to long term drift in the flow rate, but a rapid change in the flow signal, indicative of a fast flow variation, causes a corresponding change in the output signal. A comparator circuit compares the output signal with a reference signal, representing a given percentage of the steady state flow rate of the coolant, and generates a scram signal to initiate reactor shutdown when the output signal equals the reference signal.

    16. Generating electricity from viruses

      SciTech Connect (OSTI)

      Lee, Seung-Wuk

      2013-10-31

      Berkeley Lab's Seung-Wuk Lee discusses "Generating electricity from viruses" in this Oct. 28, 2013 talk, which is part of a Science at the Theater event entitled Eight Big Ideas.

    17. Generating electricity from viruses

      ScienceCinema (OSTI)

      Lee, Seung-Wuk

      2014-06-23

      Berkeley Lab's Seung-Wuk Lee discusses "Generating electricity from viruses" in this Oct. 28, 2013 talk, which is part of a Science at the Theater event entitled Eight Big Ideas.

    18. Next Generation Materials:

      Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

      Next Generation Materials: 1 Technology Assessment 2 Contents 3 1. Introduction to the Technology/System ............................................................................................... 1 4 1.1 Overview ....................................................................................................................................... 1 5 1.2 Public and private roles and activities .......................................................................................... 3 6 2.

    19. Biomass for Electricity Generation

      Reports and Publications (EIA)

      2002-01-01

      This paper examines issues affecting the uses of biomass for electricity generation. The methodology used in the National Energy Modeling System to account for various types of biomass is discussed, and the underlying assumptions are explained.

    20. Oscillating fluid power generator

      DOE Patents [OSTI]

      Morris, David C

      2014-02-25

      A system and method for harvesting the kinetic energy of a fluid flow for power generation with a vertically oriented, aerodynamic wing structure comprising one or more airfoil elements pivotably attached to a mast. When activated by the moving fluid stream, the wing structure oscillates back and forth, generating lift first in one direction then in the opposite direction. This oscillating movement is converted to unidirectional rotational movement in order to provide motive power to an electricity generator. Unlike other oscillating devices, this device is designed to harvest the maximum aerodynamic lift forces available for a given oscillation cycle. Because the system is not subjected to the same intense forces and stresses as turbine systems, it can be constructed less expensively, reducing the cost of electricity generation. The system can be grouped in more compact clusters, be less evident in the landscape, and present reduced risk to avian species.

    1. Next Generation Rooftop Unit

      Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

      Next Generation Rooftop Unit - CRADA Bo Shen Oak Ridge National Laboratory shenb@ornl.gov; 865-574-5745 April 3, 2013 ET R&D project in support of DOEBTO Goal of 50% Reduction in ...

    2. Vector generator scan converter

      DOE Patents [OSTI]

      Moore, James M.; Leighton, James F.

      1990-01-01

      High printing speeds for graphics data are achieved with a laser printer by transmitting compressed graphics data from a main processor over an I/O (input/output) channel to a vector generator scan converter which reconstructs a full graphics image for input to the laser printer through a raster data input port. The vector generator scan converter includes a microprocessor with associated microcode memory containing a microcode instruction set, a working memory for storing compressed data, vector generator hardward for drawing a full graphic image from vector parameters calculated by the microprocessor, image buffer memory for storing the reconstructed graphics image and an output scanner for reading the graphics image data and inputting the data to the printer. The vector generator scan converter eliminates the bottleneck created by the I/O channel for transmitting graphics data from the main processor to the laser printer, and increases printer speed up to thirty fold.

    3. Renewable energy generation sources...

      Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

      With the Molten Salt Test Loop (MSTL), Sandia and its industry partners are working to address a major barrier to cost-effectively incorporating more solar thermal power generation...

    4. Steam generator tube failures

      SciTech Connect (OSTI)

      MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

      1996-04-01

      A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service.

    5. ADJUSTABLE DOUBLE PULSE GENERATOR

      DOE Patents [OSTI]

      Gratian, J.W.; Gratian, A.C.

      1961-08-01

      >A modulator pulse source having adjustable pulse width and adjustable pulse spacing is described. The generator consists of a cross coupled multivibrator having adjustable time constant circuitry in each leg, an adjustable differentiating circuit in the output of each leg, a mixing and rectifying circuit for combining the differentiated pulses and generating in its output a resultant sequence of negative pulses, and a final amplifying circuit for inverting and square-topping the pulses. (AEC)

    6. EIA - Electricity Generating Capacity

      U.S. Energy Information Administration (EIA) Indexed Site

      Electricity Generating Capacity Release Date: January 3, 2013 | Next Release: August 2013 Year Existing Units by Energy Source Unit Additions Unit Retirements 2011 XLS XLS XLS 2010 XLS XLS XLS 2009 XLS XLS XLS 2008 XLS XLS XLS 2007 XLS XLS XLS 2006 XLS XLS XLS 2005 XLS XLS XLS 2004 XLS XLS XLS 2003 XLS XLS XLS Source: Form EIA-860, "Annual Electric Generator Report." Related links Electric Power Monthly Electric Power Annual Form EIA-860 Source Data

    7. Compact Mesh Generator

      Energy Science and Technology Software Center (OSTI)

      2007-02-02

      The CMG is a small, lightweight, structured mesh generation code. It features a simple text input parser that allows setup of various meshes via a small set of text commands. Mesh generation data can be output to text, the silo file format, or the API can be directly queried by applications. It can run serially or in parallel via MPI. The CMG includes the ability to specify varius initial conditions on a mesh via meshmore » tags.« less

    8. Fuel cell generator

      DOE Patents [OSTI]

      Makiel, Joseph M.

      1985-01-01

      A high temperature solid electrolyte fuel cell generator comprising a housing means defining a plurality of chambers including a generator chamber and a combustion products chamber, a porous barrier separating the generator and combustion product chambers, a plurality of elongated annular fuel cells each having a closed end and an open end with the open ends disposed within the combustion product chamber, the cells extending from the open end through the porous barrier and into the generator chamber, a conduit for each cell, each conduit extending into a portion of each cell disposed within the generator chamber, each conduit having means for discharging a first gaseous reactant within each fuel cell, exhaust means for exhausting the combustion product chamber, manifolding means for supplying the first gaseous reactant to the conduits with the manifolding means disposed within the combustion product chamber between the porous barrier and the exhaust means and the manifolding means further comprising support and bypass means for providing support of the manifolding means within the housing while allowing combustion products from the first and a second gaseous reactant to flow past the manifolding means to the exhaust means, and means for flowing the second gaseous reactant into the generator chamber.

    9. New Jersey Transit FutureGrid MOU Signing

      Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

      Models for Integrating EnergyWater Facilities Atmospheric Radiation Measurement Climate ... energy resources such as backup generators, photovoltaics, and storage. ...

    10. Superconducting thermoelectric generator

      DOE Patents [OSTI]

      Metzger, J.D.; El-Genk, M.S.

      1994-01-01

      Thermoelectricity is produced by applying a temperature differential to dissimilar electrically conducting or semiconducting materials, thereby producing a voltage that is proportional to the temperature difference. Thermoelectric generators use this effect to directly convert heat into electricity; however, presently-known generators have low efficiencies due to the production of high currents which in turn cause large resistive heating losses. Some thermoelectric generators operate at efficiencies between 4% and 7% in the 800{degrees} to 1200{degrees}C range. According to its major aspects and bradly stated, the present invention is an apparatus and method for producing electricity from heat. In particular, the invention is a thermoelectric generator that juxtaposes a superconducting material and a semiconducting material - so that the superconducting and the semiconducting materials touch - to convert heat energy into electrical energy without resistive losses in the temperature range below the critical temperature of the superconducting material. Preferably, an array of superconducting material is encased in one of several possible configurations within a second material having a high thermal conductivity, preferably a semiconductor, to form a thermoelectric generator.

    11. MCNP LWR Core Generator

      SciTech Connect (OSTI)

      Fischer, Noah A.

      2012-08-14

      The reactor core input generator allows for MCNP input files to be tailored to design specifications and generated in seconds. Full reactor models can now easily be created by specifying a small set of parameters and generating an MCNP input for a full reactor core. Axial zoning of the core will allow for density variation in the fuel and moderator, with pin-by-pin fidelity, so that BWR cores can more accurately be modeled. LWR core work in progress: (1) Reflectivity option for specifying 1/4, 1/2, or full core simulation; (2) Axial zoning for moderator densities that vary with height; (3) Generating multiple types of assemblies for different fuel enrichments; and (4) Parameters for specifying BWR box walls. Fuel pin work in progress: (1) Radial and azimuthal zoning for generating further unique materials in fuel rods; (2) Options for specifying different types of fuel for MOX or multiple burn assemblies; (3) Additional options for replacing fuel rods with burnable poison rods; and (4) Control rod/blade modeling.

    12. MHD Generating system

      DOE Patents [OSTI]

      Petrick, Michael; Pierson, Edward S.; Schreiner, Felix

      1980-01-01

      According to the present invention, coal combustion gas is the primary working fluid and copper or a copper alloy is the electrodynamic fluid in the MHD generator, thereby eliminating the heat exchangers between the combustor and the liquid-metal MHD working fluids, allowing the use of a conventional coalfired steam bottoming plant, and making the plant simpler, more efficient and cheaper. In operation, the gas and liquid are combined in a mixer and the resulting two-phase mixture enters the MHD generator. The MHD generator acts as a turbine and electric generator in one unit wherein the gas expands, drives the liquid across the magnetic field and thus generates electrical power. The gas and liquid are separated, and the available energy in the gas is recovered before the gas is exhausted to the atmosphere. Where the combustion gas contains sulfur, oxygen is bubbled through a side loop to remove sulfur therefrom as a concentrated stream of sulfur dioxide. The combustor is operated substoichiometrically to control the oxide level in the copper.

    13. Spherical neutron generator

      DOE Patents [OSTI]

      Leung, Ka-Ngo

      2006-11-21

      A spherical neutron generator is formed with a small spherical target and a spherical shell RF-driven plasma ion source surrounding the target. A deuterium (or deuterium and tritium) ion plasma is produced by RF excitation in the plasma ion source using an RF antenna. The plasma generation region is a spherical shell between an outer chamber and an inner extraction electrode. A spherical neutron generating target is at the center of the chamber and is biased negatively with respect to the extraction electrode which contains many holes. Ions passing through the holes in the extraction electrode are focused onto the target which produces neutrons by D-D or D-T reactions.

    14. Thermoacoustic magnetohydrodynamic electrical generator

      DOE Patents [OSTI]

      Wheatley, J.C.; Swift, G.W.; Migliori, A.

      1984-11-16

      A thermoacoustic magnetohydrodynamic electrical generator includes an intrinsically irreversible thermoacoustic heat engine coupled to a magnetohydrodynamic electrical generator. The heat engine includes an electrically conductive liquid metal as the working fluid and includes two heat exchange and thermoacoustic structure assemblies which drive the liquid in a push-pull arrangement to cause the liquid metal to oscillate at a resonant acoustic frequency on the order of 1000 Hz. The engine is positioned in the field of a magnet and is oriented such that the liquid metal oscillates in a direction orthogonal to the field of the magnet, whereby an alternating electrical potential is generated in the liquid metal. Low-loss, low-inductance electrical conductors electrically connected to opposite sides of the liquid metal conduct an output signal to a transformer adapted to convert the low-voltage, high-current output signal to a more usable higher voltage, lower current signal.

    15. Thermoacoustic magnetohydrodynamic electrical generator

      DOE Patents [OSTI]

      Wheatley, John C.; Swift, Gregory W.; Migliori, Albert

      1986-01-01

      A thermoacoustic magnetohydrodynamic electrical generator includes an intrinsically irreversible thermoacoustic heat engine coupled to a magnetohydrodynamic electrical generator. The heat engine includes an electrically conductive liquid metal as the working fluid and includes two heat exchange and thermoacoustic structure assemblies which drive the liquid in a push-pull arrangement to cause the liquid metal to oscillate at a resonant acoustic frequency on the order of 1,000 Hz. The engine is positioned in the field of a magnet and is oriented such that the liquid metal oscillates in a direction orthogonal to the field of the magnet, whereby an alternating electrical potential is generated in the liquid metal. Low-loss, low-inductance electrical conductors electrically connected to opposite sides of the liquid metal conduct an output signal to a transformer adapted to convert the low-voltage, high-current output signal to a more usable higher voltage, lower current signal.

    16. Sidetone generator flowmeter

      DOE Patents [OSTI]

      Fritz, Robert J.

      1986-01-01

      A flowmeter is provided which uses the sidetones generated in a cavity formed in the wall of a flowpipe or the like in response to fluid flowing past the cavity to provide a measure of the flow velocity of that fluid. The dimensions of the cavity are such as to provide a dominant vibratory frequency which is sensed by a pressure sensor. The flowmeter is adapted for use for a range of frequencies in which the Strouhal number is constant and under these conditions the vibratory frequency is directly related to the flow rate. The tone generator cavity and pressure transducer form a unit which is connected in-line in the flowpipe.

    17. Sidetone generator flowmeter

      DOE Patents [OSTI]

      Fritz, R.J.

      1983-11-03

      A flowmeter is provided which uses the sidetones generated in a cavity formed in the wall of a flowpipe or the like in response to fluid flowing past the cavity to provide a measure of the flow velocity of that fluid. The dimensions of the cavity are such as to provide a dominant vibratory frequency which is sensed by a pressure sensor. The flowmeter is adapted for use for a range of frequencies in which the Strouhal number is constant and under these conditions the vibratory frequency is directly related to the flow rate. The tone generator cavity and pressure transducer form a unit which is connected in-line in the flowpipe.

    18. External split field generator

      DOE Patents [OSTI]

      Thundat, Thomas George; Van Neste, Charles W.; Vass, Arpad Alexander

      2012-02-21

      A generator includes a coil disposed about a core. A first stationary magnetic field source may be disposed on a first end portion of the core and a second stationary magnetic field source may be disposed on a second end portion of core. The first and second stationary magnetic field sources apply a stationary magnetic field to the coil. An external magnetic field source may be disposed outside the coil to apply a moving magnetic field to the coil. Electrical energy is generated in response to an interaction between the coil, the moving magnetic field, and the stationary magnetic field.

    19. Z' generation with PYTHIA

      SciTech Connect (OSTI)

      Ciobanu, Catalin; Junk, Thomas; Veramendi, Gregory; Lee, Jedong; De Lentdecker, Gilles; McFarland, Kevin; Maeshima, Kaori; /Fermilab

      2005-07-01

      This document is intended as a guide for getting started with the Z' generation with PYTHIA[1]. Several different conventions used in literature are discussed, and the conversion among these is given. The Z' couplings to fermions are given for the sequential Z', the Z' model-lines of Ref. [2], and the popular E6 Z' models.

    20. Iridium 191-M generator

      DOE Patents [OSTI]

      Treves, Salvador; Cheng, Chris C.

      1988-03-08

      Potassium osmate, of the formula K.sub.2 Os O.sub.2 (OH).sub.4), used to make a column for the generation of Ir-191 m, which is used in first pass angiography to detect cardiac defects in patients.

    1. Fuel cell generator

      DOE Patents [OSTI]

      Isenberg, Arnold O.

      1983-01-01

      High temperature solid oxide electrolyte fuel cell generators which allow controlled leakage among plural chambers in a sealed housing. Depleted oxidant and fuel are directly reacted in one chamber to combust remaining fuel and preheat incoming reactants. The cells are preferably electrically arranged in a series-parallel configuration.

    2. Iridium 191-m generator

      DOE Patents [OSTI]

      Treves, S.; Cheng, C.C.

      1988-03-08

      Potassium osmate, of the formula K[sub 2]OsO[sub 2](OH)[sub 4], is used to make a column for the generation of Ir-191 m, which is used in first pass angiography to detect cardiac defects in patients. 2 figs.

    3. DEVELOPMENT OF ANALYTICAL METHODS FOR DETERMINING SUPPRESSOR CONCENTRATION IN THE MCU NEXT GENERATION SOLVENT (NGS)

      SciTech Connect (OSTI)

      Taylor-Pashow, K.; Fondeur, F.; White, T.; Diprete, D.; Milliken, C.

      2013-07-31

      Savannah River National Laboratory (SRNL) was tasked with identifying and developing at least one, but preferably two methods for quantifying the suppressor in the Next Generation Solvent (NGS) system. The suppressor is a guanidine derivative, N,N',N"-tris(3,7-dimethyloctyl)guanidine (TiDG). A list of 10 possible methods was generated, and screening experiments were performed for 8 of the 10 methods. After completion of the screening experiments, the non-aqueous acid-base titration was determined to be the most promising, and was selected for further development as the primary method. {sup 1}H NMR also showed promising results from the screening experiments, and this method was selected for further development as the secondary method. Other methods, including {sup 36}Cl radiocounting and ion chromatography, also showed promise; however, due to the similarity to the primary method (titration) and the inability to differentiate between TiDG and TOA (tri-n-ocytlamine) in the blended solvent, {sup 1}H NMR was selected over these methods. Analysis of radioactive samples obtained from real waste ESS (extraction, scrub, strip) testing using the titration method showed good results. Based on these results, the titration method was selected as the method of choice for TiDG measurement. {sup 1}H NMR has been selected as the secondary (back-up) method, and additional work is planned to further develop this method and to verify the method using radioactive samples. Procedures for analyzing radioactive samples of both pure NGS and blended solvent were developed and issued for the both methods.

    4. GASIFICATION FOR DISTRIBUTED GENERATION

      SciTech Connect (OSTI)

      Ronald C. Timpe; Michael D. Mann; Darren D. Schmidt

      2000-05-01

      A recent emphasis in gasification technology development has been directed toward reduced-scale gasifier systems for distributed generation at remote sites. The domestic distributed power generation market over the next decade is expected to be 5-6 gigawatts per year. The global increase is expected at 20 gigawatts over the next decade. The economics of gasification for distributed power generation are significantly improved when fuel transport is minimized. Until recently, gasification technology has been synonymous with coal conversion. Presently, however, interest centers on providing clean-burning fuel to remote sites that are not necessarily near coal supplies but have sufficient alternative carbonaceous material to feed a small gasifier. Gasifiers up to 50 MW are of current interest, with emphasis on those of 5-MW generating capacity. Internal combustion engines offer a more robust system for utilizing the fuel gas, while fuel cells and microturbines offer higher electric conversion efficiencies. The initial focus of this multiyear effort was on internal combustion engines and microturbines as more realistic near-term options for distributed generation. In this project, we studied emerging gasification technologies that can provide gas from regionally available feedstock as fuel to power generators under 30 MW in a distributed generation setting. Larger-scale gasification, primarily coal-fed, has been used commercially for more than 50 years to produce clean synthesis gas for the refining, chemical, and power industries. Commercial-scale gasification activities are under way at 113 sites in 22 countries in North and South America, Europe, Asia, Africa, and Australia, according to the Gasification Technologies Council. Gasification studies were carried out on alfalfa, black liquor (a high-sodium waste from the pulp industry), cow manure, and willow on the laboratory scale and on alfalfa, black liquor, and willow on the bench scale. Initial parametric tests

    5. Exelôn. Generation

      Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

      Exeln. Generation 4300 Winfield Road Warrenville, Illinois 60555 Writer's Direct Dial: ... On March 14, 2011, representatives of Exelon Generation Company, LLC and Exelon Nuclear ...

    6. Interconnection Standards for Small Generators

      Broader source: Energy.gov [DOE]

      NOTE: On July 2016, FERC issued Order 827 revising the Small Generation Interconnection Agreement (SGIA) to require newly interconnecting small generators under 20 MW to ride through abnormal...

    7. Hydro Power (pbl/generation)

      Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

      Generation > Generation Hydro Power FCRPS Hydro Projects FCRPS Information Kiosk Current Hydrological Info Fish Funding Agreement FCRPS Definitions Wind Power Monthly GSP BPA White...

    8. SSE Generation | Open Energy Information

      Open Energy Info (EERE)

      SSE Generation Jump to: navigation, search Name: SSE Generation Place: Perth, Scotland, United Kingdom Zip: PH1 3AQ Sector: Renewable Energy Product: Owns and operates around half...

    9. Solaire Generation | Open Energy Information

      Open Energy Info (EERE)

      Generation Place: New York, New York Zip: 10001 Sector: Solar Product: New York-based rooftop PV mounting systems and solar canopy maker. References: Solaire Generation1 This...

    10. Thermoacoustic magnetohydrodynamic electrical generator

      SciTech Connect (OSTI)

      Wheatley, J.C.; Swift, G.W.; Migliori, A.

      1986-07-08

      A thermoacoustic magnetohydrodynamic electrical generator is described comprising a magnet having a magnetic field, an elongate hollow housing containing an electrically conductive liquid and a thermoacoustic structure positioned in the liquid, heat exchange means thermally connected to the thermoacoustic structure for inducing the liquid to oscillate at an acoustic resonant frequency within the housing. The housing is positioned in the magnetic field and oriented such that the direction of the magnetic field and the direction of oscillatory motion of the liquid are substantially orthogonal to one another, first and second electrical conductor means connected to the liquid on opposite sides of the housing along an axis which is substantially orthogonal to both the direction of the magnetic field and the direction of oscillatory motion of the liquid, an alternating current output signal is generated in the conductor means at a frequency corresponding to the frequency of the oscillatory motion of the liquid.