Powered by Deep Web Technologies
Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Aperture lamp  

DOE Patents (OSTI)

A discharge lamp includes means for containing a light emitting fill, the fill being capable of absorbing light at one wavelength and re-emitting the light at a different wavelength, the light emitted from the fill having a first spectral power distribution in the absence of reflection of light back into the fill; means for exciting the fill to cause the fill to emit light; and means for reflecting some of the light emitted by the fill back into the fill while allowing some light to exit, the exiting light having a second spectral power distribution with proportionately more light in the visible region as compared to the first spectral power distribution, wherein the light re-emitted by the fill is shifted in wavelength with respect to the absorbed light and the magnitude of the shift is in relation to an effective optical path length. Another discharge lamp includes an envelope; a fill which emits light when excited disposed in the envelope; a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light; and a reflective ceramic structure disposed around the envelope and defining an light emitting opening, wherein the structure comprises a sintered body built up directly on the envelope and made from a combination of alumina and silica.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD)

2003-01-01T23:59:59.000Z

2

Lamp Divisions  

Office of Legacy Management (LM)

--- --- /A;; i :' r%i;in~house ilEc;' i:Z3:~cra:ion Lamp Divisions , _.. (I +i. 0 :,,,rg. . I . . -= i?e p/q! qe)-' &se pw E.rcale?l iev, Je!sey 07m March 20, 1 gs? ::r . J. A. Jones I ti. 5. Muclear Regulatory Commission .> = ..- haterials Licensing Branch -s - ,.I, - - Division of Fuel Cycle and hateri al Safety LY. , $2 - _ . ' -' . 3 _- - Yeshington, C. C. 2@555 - :_ :--, =-- -- .-?J -.: y...., : :- 7 Dear Mr. Jones : y-- --, ? . *I 2=15 2 r; X -P The following is our final report of the decontamination efZor?s takz in our Bui Iding 7 basement and wi 11 also serve to update our report i& November 12, 1980. As stated in NRC' s report of December 22, 1983, two closeout inspect ions were conducted by your King of Prussia off i ce on November 21 and December 2,

3

LED lamp  

SciTech Connect

There is herein described a lamp for providing white light comprising a plurality of light sources positioned on a substrate. Each of said light sources comprises a blue light emitting diode (LED) and a dome that substantially covers said LED. A first portion of said blue light from said LEDs is transmitted through said domes and a second portion of said blue light is converted into a red light by a first phosphor contained in said domes. A cover is disposed over all of said light sources that transmits at least a portion of said red and blue light emitted by said light sources. The cover contains a second phosphor that emits a yellow light in response to said blue light. The red, blue and yellow light combining to form the white light and the white light having a color rendering index (CRI) of at least about 80.

Galvez, Miguel; Grossman, Kenneth; Betts, David

2013-11-12T23:59:59.000Z

4

Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

Electric lighting constitutes approximately 21-23 % of the electric grid load in the United States. The higher energy and maintenance costs of incandescent lamps, combined with the favorable economics of high-efficiency compact fluorescent lamps (CFLs), are making CFLs the increasingly popular choice for both residential and commercial lighting. Utility incentive and rebate programs to stimulate CFL use and the beginnings of a ban on incandescent lamps are enhancing CFL penetration levels in these enviro...

2009-12-17T23:59:59.000Z

5

Jacketed lamp bulb envelope  

DOE Patents (OSTI)

A jacketed lamp bulb envelope includes a ceramic cup having an open end and a partially closed end, the partially closed end defining an aperture, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material at least partially covering a portion of the bulb not abutting the aperture. The reflective ceramic material may substantially fill an interior volume of the ceramic cup not occupied by the bulb. The ceramic cup may include a structural feature for aiding in alignment of the jacketed lamp bulb envelope in a lamp. The ceramic cup may include an external flange about a periphery thereof. One example of a jacketed lamp bulb envelope includes a ceramic cup having an open end and a closed end, a ceramic washer covering the open end of the ceramic cup, the washer defining an aperture therethrough, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material filling an interior volume of the ceramic cup not occupied by the bulb. A method of packing a jacketed lamp bulb envelope of the type comprising a ceramic cup with a lamp bulb disposed therein includes the steps of filling the ceramic cup with a flowable slurry of reflective material, and applying centrifugal force to the cup to pack the reflective material therein.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Gitsevich, Aleksandr (Gaithersburg, MD); Bass, Gary K. (Mt. Airy, MD); Dolan, James T. (Frederick, MD); Kipling, Kent (Gaithersburg, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Leng, Yongzhang (Damascus, MD); Levin, Izrail (Silver Spring, MD); Roy, Robert J. (Frederick, MD); Shanks, Bruce (Gaithersburg, MD); Smith, Malcolm (Alexandria, VA); Trimble, William C. (Columbia, MD); Tsai, Peter (Olney, MD)

2001-01-01T23:59:59.000Z

6

Fluorescent lamp ballast  

SciTech Connect

An electronic ballast is described having at least a first and second terminal for engaging the filaments of at least one fluorescent lamp which requires a breakdown voltage to ignite the lamp and a maintaining voltage for maintaining ionization therewithin, the electronic ballast comprising: a direct current voltage source; a transistor; a transformer having a primary winding separated into a first winding, a second winding, a third winding, and a fourth winding; the first winding connected between the voltage source and the first terminal; the second winding connected between the two terminals; the third winding connected between the second terminal and to both the transistor and to ground; the fourth winding connected between ground and the transistor; the lamp being parallel to the second winding when the lamp filaments engages the ballast terminals.

Ureche, A.

1987-08-25T23:59:59.000Z

7

Magnetic fluorescent lamp  

DOE Patents (OSTI)

The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly is enhanced by providing means for establishing a magnetic field with lines of force along the path of electron flow through the bulb of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

Berman, S.M.; Richardson R.W.

1983-12-29T23:59:59.000Z

8

Electronic Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses the fastest growing energy efficient light source the electronic compact fluorescent lamp (CFL). Business and technical market factors (Chapter 2) explain the past and future growth of the CFL market while emphasizing future technical improvements along with discussion of the importance of utility involvement in helping their customers make the switch from incandescent lamps to CFLs. The basic CFL technology is covered in Chapter 3 including test results for selected ...

2007-12-18T23:59:59.000Z

9

Fluorescent lamp ballast  

SciTech Connect

This patent describes an electronic ballast unit for a fluorescent lamp comprising: a circuit assembly having a pair of voltage input terminal and a first inductor and a capacitor in series relationship with each other to form a series resonant circuit. The circuit is adapted to be coupled to a fluorescent lamp to provide a starting voltage for the lamp; and a second inductor connected in shunt relationship to the first inductor and connected to the other input terminal. There is a core on which the first inductor and the second inductor are mounted. The core inductively couples the inductors with each other and are shaped to reduce core losses to minimize the increase of temperature of the core; the core is of a generally H-shaped configuration, and means of opposite ends of the H-shaped core to complete the magnetic flux path for each inductor, respectively.

Boyd, G.D.

1987-03-31T23:59:59.000Z

10

2X Incandescent Lamp Technology  

Science Conference Proceedings (OSTI)

The incandescent lamp was developed during the 1800s, largely reaching the design of the traditional incandescent lamp as we know it by the late 1800s. This lamp remained largely unchanged for years, providing most commercial and residential lighting demands into the 1950s and residential lighting into the 2000s. As new lighting technologies became available, the low efficacy, measured in lumens per watt, of the traditional incandescent lamp became an issue which many wanted to ...

2012-11-01T23:59:59.000Z

11

Fluorescent lamp dimming adaptor kit  

SciTech Connect

An add-on fluorescent lamp dimming adaptor is described for connecting to a conventional nondimming ballast in a fluorescent lighting system, the system including a source of ac voltage. The ballast has terminals for connecting to a fluorescent lamp, the adaptor comprising: a switching module adapted to be coupled to the terminals for switching current from the lamp, the switching module being connected in parallel with the lamp to divert current from the lamp when the switching module conducts; and a level control coupled to the switching module, the level control controlling the conductive state of the switching module to vary the current in the lamp according to a dimming control signal supplied to the level control, the level control causing the switching module to switch at a frequency in the range of 300 hertz and higher during times that the lamp current is being varied.

Alley, R.P.

1987-07-21T23:59:59.000Z

12

Flash Lighting with Fluorescent Lamp.  

E-Print Network (OSTI)

??A flash lighting circuit with the fluorescent lamp is designed to produce lighting flicker by means of controlling the operating frequency and the duty-ratio of… (more)

Hsieh, Horng

2005-01-01T23:59:59.000Z

13

Fixture conditions affect lamp performance  

SciTech Connect

This article discusses the major parameters that affect fluorescent lamp performance under fixture conditions. These parameters include fixture type, and HVAC integration, which directly determine the minimum lamp wall temperature (MLWT), and therefore, the resulting light output of the lamp/ballast system. Experimental data is presented showing that the lumen output of the lamp/ballast system can vary by as much as 20% and that the system efficacy can vary by 10% depending upon the type of fixture and HVAC system employed. 4 refs., 5 figs., 1 tab.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.

1986-11-01T23:59:59.000Z

14

Energy Cost Calculator for Compact Fluorescent Lamps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Compact Fluorescent Lamps Compact Fluorescent Lamps Energy Cost Calculator for Compact Fluorescent Lamps October 8, 2013 - 2:18pm Addthis This tool calculates the payback period for your calc retrofit project. Modify the default values to suit your project requirements. Existing incandescent lamp wattage Watts Incandescent lamp cost dollars Incandescent lamp life 1000 hours calc wattage Watts calc cost dollars calc life (6000 hours for moderate use, 10000 hours for high use) 8000 hours Number of lamps in retrofit project Hours operating per week hours Average cost of electricity 0.06 $/kWh Relamper labor costs $/hr Time taken to retrofit all lamps in this project min Time taken to relamp one lamp min Type of Relamping Practiced: Group Relamping: Calculate Simple Payback Period months

15

Inductive tuners for microwave driven discharge lamps  

DOE Patents (OSTI)

An RF powered electrodeless lamp utilizing an inductive tuner in the waveguide which couples the RF power to the lamp cavity, for reducing reflected RF power and causing the lamp to operate efficiently.

Simpson, James E. (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

16

Information Resources: LED Replacement Lamps: Current Performance...  

NLE Websites -- All DOE Office Websites (Extended Search)

incandescent lamps (e.g., A-lamps), and provided an update on ENERGY STAR criteria for LED integral replacement lamps - currently in its second draft. Robert Lingard of Pacific...

17

A projective LED dental lamp design.  

E-Print Network (OSTI)

??Halogen lamps are mostly applied as a light source to the traditional lamp for medical treatment due to its proper color temperature, but it has… (more)

Chung, Yu-Lin

2011-01-01T23:59:59.000Z

18

Lamp bulb with integral reflector  

SciTech Connect

An improved electrodeless discharge lamp bulb includes an integral ceramic reflector as a portion of the bulb envelope. The bulb envelope further includes two pieces, a reflector portion or segment is cast quartz ceramic and a light transmissive portion is a clear fused silica. In one embodiment, the cast quartz ceramic segment includes heat sink fins or stubs providing an increased outside surface area to dissipate internal heat. In another embodiment, the quartz ceramic segment includes an outside surface fused to eliminate gas permeation by polishing.

Levin, Izrail (Silver Spring, MD); Shanks, Bruce (Gaithersburg, MD); Sumner, Thomas L. (Wheaton, MD)

2001-01-01T23:59:59.000Z

19

Energy saving controller for fluorescent lamps.  

E-Print Network (OSTI)

??Although fluorescent lamp is a very efficient lighting device in daily life, still the high harmonic distortion and low power factor cause unnecessary energy consumption.… (more)

Cheong, Zhi Xiong

2010-01-01T23:59:59.000Z

20

Discharge lamp with reflective jacket  

DOE Patents (OSTI)

A discharge lamp includes an envelope, a fill which emits light when excited disposed in the envelope, a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed around the envelope and defining an opening, the reflector being configured to reflect some of the light emitted by the fill back into the fill while allowing some light to exit through the opening. The reflector may be made from a material having a similar thermal index of expansion as compared to the envelope and which is closely spaced to the envelope. The envelope material may be quartz and the reflector material may be either silica or alumina. The reflector may be formed as a jacket having a rigid structure which does not adhere to the envelope. The lamp may further include an optical clement spaced from the envelope and configured to reflect an unwanted component of light which exited the envelope back into the envelope through the opening in the reflector. Light which can be beneficially recaptured includes selected wavelength regions, a selected polarization, and selected angular components.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Kipling, Kent (Gaithersburg, MD)

2001-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Portable lamp with dynamically controlled lighting distribution  

DOE Patents (OSTI)

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) arranged vertically with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum insures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2001-01-01T23:59:59.000Z

22

DuraLamp USA: Order (2010-CE-0912)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered DuraLamp USA, Inc. to pay a $2,500 civil penalty after finding DuraLamp USA had failed to certify that model PAR 30, an incandescent reflector lamp, complies with the applicable energy conservation standards.

23

Solid-state lamp with integral occupancy sensor  

E-Print Network (OSTI)

Previous work demonstrated a retrofit proximity detector for fluorescent lamps using the lamp's own stray electric fields. This paper extends the retrofit sensor system to a solid-state (LED) lamp. The design and implementation ...

Cooley, John J.

24

Compact Fluorescent Lamps : Technologies : From the Lab to the...  

NLE Websites -- All DOE Office Websites (Extended Search)

process. (Left) Compact Fluorescent Lamp; (Right) Cover of the 'Lighting Retrofit Workbook' (Left) Compact Fluorescent Lamp (CFL) (Right) Retrofitting national parks...

25

Driver Circuit for White LED Lamps with TRIAC Dimming Control.  

E-Print Network (OSTI)

??An efficient Light Emitting Diode (LED) lamp driver circuit is proposed for retrofitting the conventionally used incandescent lamps with existing TRIAC dimmer. The dimming feature… (more)

Weng, Szu-Jung

2012-01-01T23:59:59.000Z

26

Lamp system for uniform semiconductor wafer heating  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

2001-01-01T23:59:59.000Z

27

LED lamp power management system and method  

DOE Patents (OSTI)

An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A. M.

2013-03-19T23:59:59.000Z

28

High frequency inductive lamp and power oscillator  

DOE Patents (OSTI)

A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and/or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to match the driving frequency of the oscillator to a plurality of tuning states of the lamp.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Dolan, James T. (Frederick, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Leng, Yongzhang (Damascus, MD)

2000-01-01T23:59:59.000Z

29

Long-Term Performance of Screwbase Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

The packaging material for compact fluorescent lamps normally includes some claim regarding expected lamp lifetime. This claimed lifetime is generally not obtained through rigorous testing. This study shows how different operating cycles, components, and lamp and ballast designs affect screwbase compact fluorescent lamp (SCFL) life.

2000-04-11T23:59:59.000Z

30

Building Technologies Office: Fluorescent and Incandescent Lamps Public  

NLE Websites -- All DOE Office Websites (Extended Search)

Fluorescent and Fluorescent and Incandescent Lamps Public Meeting to someone by E-mail Share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Facebook Tweet about Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Twitter Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Google Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Delicious Rank Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Digg Find More places to share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on AddThis.com... About Standards & Test Procedures Implementation, Certification & Enforcement

31

Max Tech and Beyond: Fluorescent Lamps  

Science Conference Proceedings (OSTI)

Fluorescent lamps are the most widely used artificial light source today, responsible for approximately 70% of the lumens delivered to our living spaces globally. The technology was originally commercialized in the 1930's, and manufacturers have been steadily improving the efficacy of these lamps over the years through modifications to the phosphors, cathodes, fill-gas, operating frequency, tube diameter and other design attributes. The most efficient commercially available fluorescent lamp is the 25 Watt T5 lamp. This lamp operates at 114-116 lumens per watt while also providing good color rendering and more than 20,000 hours of operating life. Industry experts interviewed indicated that while this lamp is the most efficient in the market today, there is still a further 10 to 14% of potential improvements that may be introduced to the market over the next 2 to 5 years. These improvements include further developments in phosphors, fill-gas, cathode coatings and ultraviolet (UV) reflective glass coatings. The commercialization of these technology improvements will combine to bring about efficacy improvements that will push the technology up to a maximum 125 to 130 lumens per watt. One critical issue raised by researchers that may present a barrier to the realization of these improvements is the fact that technology investment in fluorescent lamps is being reduced in order to prioritize research into light emitting diodes (LEDs) and ceramic metal halide high intensity discharge (HID) lamps. Thus, it is uncertain whether these potential efficacy improvements will be developed, patented and commercialized. The emphasis for premium efficacy will continue to focus on T5 lamps, which are expected to continue to be marketed along with the T8 lamp. Industry experts highlighted the fact that an advantage of the T5 lamp is the fact that it is 40% smaller and yet provides an equivalent lumen output to that of a T8 or T12 lamp. Due to its smaller form factor, the T5 lamp contains less material (i.e., glass, fill gas and phosphor), and has a higher luminance, enabling fixtures to take advantage of the smaller lamp size to improve the optics and provide more efficient overall system illuminance. In addition to offering the market a high-quality efficacious light source, another strong value proposition of fluorescent lighting is its long operating life. In today's market, one manufacturer is offering fluorescent lamps that have a rated life of 79,000 hours - which represents 18 years of service at 12 hours per day, 365 days per year. These lamps, operated using a long-life ballast specified by the manufacturer, take advantage of improvements in cathode coatings, fill gas chemistry and pressure to extend service life by a factor of four over conventional fluorescent lamps. It should be noted that this service life is also longer (approximately twice as long) as today's high-quality LED products. The fluorescent market is currently focused on the T5 and T8 lamp diameters, and it is not expected that other diameters would be introduced. Although T8 is a more optimal diameter from an efficacy perspective, the premium efficiency and optimization effort has been focused on T5 lamps because they are 40% smaller than T8, and are designed to operate at a higher temperature using high-frequency electronic ballasts. The T5 lamp offers savings in terms of materials, packaging and shipping, as well as smaller fixtures with improved optical performance. Manufacturers are actively researching improvements in four critical areas that are expected to yield additional efficacy improvements of approximately 10 to 14 percent over the next five years, ultimately achieving approximately 130 lumens per watt by 2015. The active areas of research where these improvements are anticipated include: (1) Improved phosphors which continue to be developed and patented, enabling higher efficacies as well as better color rendering and lumen maintenance; (2) Enhanced fill gas - adjusting proportions of argon, krypton, neon and xenon to optimize performance, while also m

Scholand, Michael

2012-04-01T23:59:59.000Z

32

High frequency inductive lamp and power oscillator  

DOE Patents (OSTI)

A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and I or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to adjust the driving frequency of the oscillator.

MacLennan, Donald A. (Gaithersburg, MD); Dymond, Jr., Lauren E. (North Potomac, MD); Gitsevich, Aleksandr (Montgomery Village, MD); Grimm, William G. (Silver Spring, MD); Kipling, Kent (Gaithersburg, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Ola, Samuel A. (Silver Spring, MD); Simpson, James E. (Gaithersburg, MD); Trimble, William C. (Columbia, MD); Tsai, Peter (Olney, MD); Turner, Brian P. (Damascus, MD)

2001-01-01T23:59:59.000Z

33

Survivability of Electronic Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This EPRI Technical Report addresses the fastest growing energy efficient light source8212the electronic compact fluorescent lamp (CFL). Because some of the failure modes for screw-in CFLs are different than those for plug-in CFLs, a cursory review of the difference between the two types of CFLs is provided in the first part of Chapter 2. A broad definition of shortened-life CFLs is also provided in Chapter 2 with an emphasis on revisiting mortality curves, the 10-minute lamp start, other relevant defini...

2008-03-31T23:59:59.000Z

34

Energy Performance of Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents the results of tests performed at the Worcester Polytechnic Institute, in contract with the EPRI Power Electronics Applications Center (PEAC), to determine the light output, power consumption, efficiency, and power factor of off-the-shelf electronic and magnetic compact fluorescent lamps.

2003-12-31T23:59:59.000Z

35

Laboratory Evaluation of LED T8 Replacement Lamp Products  

Science Conference Proceedings (OSTI)

A report on a lab setting analysis involving LED lamps intended to directly replace T8 fluorescent lamps (4') showing light output, power, and economic comparisons with other fluorescent options.

Richman, Eric E.; Kinzey, Bruce R.; Miller, Naomi J.

2011-05-23T23:59:59.000Z

36

The Effects of Table Lamp Shade Shape and Compact Fluorescent...  

NLE Websites -- All DOE Office Websites (Extended Search)

The Effects of Table Lamp Shade Shape and Compact Fluorescent Lamp Burning Position on Visual Comfort Speaker(s): Zaidi Abdullah Date: March 15, 2001 - 12:00pm Location: Bldg. 90...

37

Light Flicker in Compact Fluorescent Lamps Caused by Voltage Fluctuations  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the EPRI Power Electronics Applications Center (PEAC) Power Quality Test Facility to characterize the light output of an incandescent lamp and compact fluorescent lamps during voltage fluctuations.

2003-12-31T23:59:59.000Z

38

Performance of electronic ballasts and lighting controllers with 34-W fluorescent lamps: Final report  

SciTech Connect

This study has measured the performance of energy-saving 34-watt F40, T-12, rapid-start, lite white fluorescent lamps being operated by solid-state ballasts and lighting control equipment. The performances of these lamps are compared with those of 40-watt F40, T-12 rapid-start cool white fluorescent lamp systems studied in the prior phase of this project. With the 34-watt F40 lamps and various solid-state ballasts, system efficacy ranged from 67 to 84 lumens per watt and ballast factor from 0.756 to 0.908. Average system efficacy using the 34-watt lamps exceeded that of systems using 40-watt lamps and the same solid-state ballasts by only 1 percent even though the 34-watt lamps is about 6 percent more efficacious than the 40-watt lamp. This apparent discrepancy is due to increased ballast losses when operating the 34-watt lamps. However, the system efficacy of the 34-watt lamps used with a solid-state ballast exceeded that of a 34-watt, two-lamp system using the standard core-coil ballast by as much as 29 percent. A T-8 fluorescent lamp system with a smaller lamp diameter was also included in the study. Operating this lamp with a solid-state ballast produced a high system efficacy of 90 lumens per watt, a 39 percent improvement over the efficacy of a 40-watt F40 system using the standard core-coil ballast. The use of static controllers with 34-watt F40 lamps can result in excessive flickering (46 percent) and the generation of a second harmonic as high as 96 percent of the fundamental frequency. The dynamic controllers, when used to dim the 34-watt lamps generally cannot be dimmed as low as the 40-watt lamp system without flickering. In general, the 34-watt energy-saving lamps are appropriate as a retrofit to reduce illumination levels. However, for new construction, the 40-watt F40 argon filled lamps cost less, perform better, and provide a more reliable system. 5 refs., 27 figs., 9 tabs.

Verderber, R.R.

1988-06-01T23:59:59.000Z

39

Novel Nanophosphors for High Efficiency Fluorescent Lamps  

SciTech Connect

This is the Final Report of the Novel Nanophosphors for High Efficiency Fluorescent Lamps, Department of Energy (DOE). The overall goal of this three-year program is to develop novel hybrid phosphors by coating commercially available lamp phosphors with highly stable wide band-gap nanocrystalline phosphors (NCP). The prime technical approach is the development of NCP quantum-splitting phosphor (QSP) and ultra-violet (UV) emitting phosphors with quantum efficiencies exceeding that of the conventional phosphors at 185 nm. The novel hybrid phosphors will increase the efficiency of the fluorescent lamps by up to 32%, enabling total energy savings of 0.26 quads, the reduction in the U.S. energy bill by $6.5 billion and the reduction of the annual carbon emission by 4.1 billion kilogram. Our work started by investigating through modeling calculations the requirement for the particle size of the NCP. Our work to develop suitable nanocrystalline phosphors started with the known oxide quantum splitting and UV emitting phosphors. We demonstrated several synthesis techniques for the production of high quality nanocrystalline materials that crystallizes in the desired phase and with the desired particle size. In collaboration with our subcontractor we demonstrated the feasibility for the manufacture of NC phosphors. We also demonstrated novel techniques of coating the NCP on the surface of micron sized phosphors. Our chief achievement pertains to the successful testing of the coated hybrid phosphor systems in linear fluorescent lamps. In linear fluorescent lamp tests, we have demonstrated up to 7% increase in the efficacy of hybrid phosphors over the conventional (uncoated) phosphors. We have also demonstrated the improvement in the lumen maintenance of the coated phosphors. A hybrid phosphor system based on the commercial red emitting phosphor, Y{sub 2}O{sub 3}:Eu{sup 3+} did not show the anticipated improvement in lamp efficacy. We explored the reasons for this observation, which are detailed in this report. Within the program we have carried out fundamental investigations into the physical processes that determine the quantum splitting behavior of the Pr{sup 3+} ion in solids. Specifically, we have investigated the quantum splitting luminescence of this ion in the LaPO{sub 4}, SrAl{sub 12}O{sub 19} and LiLaP{sub 4}O{sub 12} host lattices. In this final report we summarize the technical work completed under the Program, summarize our findings about the performance limits of the various technologies we investigated, and outline promising paths for future work.

Alok Srivatava

2007-03-31T23:59:59.000Z

40

Controlling the vapor pressure of a mercury lamp  

DOE Patents (OSTI)

The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled. 2 figs.

Grossman, M.W.; George, W.A.

1988-05-24T23:59:59.000Z

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Controlling the vapor pressure of a mercury lamp  

DOE Patents (OSTI)

The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled.

Grossman, Mark W. (Belmont, MA); George, William A. (Rockport, MA)

1988-01-01T23:59:59.000Z

42

LED lamp color control system and method  

DOE Patents (OSTI)

An LED lamp color control system and method including an LED lamp having an LED controller 58; and a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 determines whether the LED source 80 is in a feedback controllable range, stores measured optical flux for the LED source 80 when the LED source 80 is in the feedback controllable range, and bypasses storing the measured optical flux when the LED source 80 is not in the feedback controllable range.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A.M.

2013-02-05T23:59:59.000Z

43

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible is disclosed. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture. 20 figs.

MacLennan, D.A.; Turner, B.; Kipling, K.

1999-05-11T23:59:59.000Z

44

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture.

MacLennan, Donald A. (Butler, PA); Turner, Brian (Damascus, MD); Kipling, Kent (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

45

Lighting Group: Sources and Ballasts: LED Reflector Lamp  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Reflector Lamp LED Reflector Lamp LED Reflector Lamp Objective LED reflector lamp The goal of this project is to develop a revolutionary new reflector lamp which offers many advantages over current incandescent reflector lamps, including: three times greater efficiency ten times the rated life greater optical and performance properties use of light emitting diodes (LEDs) to generate the light. Although LEDs have been commercially available since the late 1960’s, recent dramatic improvements in LED technology have led to white light devices with efficiencies that meet or exceed those of a standard incandescent lamp. This project will build upon these improvements to develop a new type of source for focusing light. Contact Information For more information on this project, please contact:

46

High output lamp with high brightness  

DOE Patents (OSTI)

An ultra bright, low wattage inductively coupled electrodeless aperture lamp is powered by a solid state RF source in the range of several tens to several hundreds of watts at various frequencies in the range of 400 to 900 MHz. Numerous novel lamp circuits and components are disclosed including a wedding ring shaped coil having one axial and one radial lead, a high accuracy capacitor stack, a high thermal conductivity aperture cup and various other aperture bulb configurations, a coaxial capacitor arrangement, and an integrated coil and capacitor assembly. Numerous novel RF circuits are also disclosed including a high power oscillator circuit with reduced complexity resonant pole configuration, parallel RF power FET transistors with soft gate switching, a continuously variable frequency tuning circuit, a six port directional coupler, an impedance switching RF source, and an RF source with controlled frequency-load characteristics. Numerous novel RF control methods are disclosed including controlled adjustment of the operating frequency to find a resonant frequency and reduce reflected RF power, controlled switching of an impedance switched lamp system, active power control and active gate bias control.

Kirkpatrick, Douglas A. (Great Falls, VA); Bass, Gary K. (Mt. Airy, MD); Copsey, Jesse F. (Germantown, MD); Garber, Jr., William E. (Poolesville, MD); Kwong, Vincent H. (Vancouver, CA); Levin, Izrail (Silver Spring, MD); MacLennan, Donald A. (Gaithersburg, MD); Roy, Robert J. (Frederick, MD); Steiner, Paul E. (Olney, MD); Tsai, Peter (Olney, MD); Turner, Brian P. (Damascus, MD)

2002-01-01T23:59:59.000Z

47

High intensity discharge lamp self-adjusting ballast system sensitive to the radiant energy or heat of the lamp  

SciTech Connect

This patent describes a self-adjusting ballast system for mercury vapor, high intensity discharge lamps having outputs of 100 watts or greater, comprising: a direct current source; a lamp circuit containing a high intensity discharge lamp; sensing means for sensing the radiant energy output of the lamp; a pulse width modulator which, in response to the output of the sensing means, varies the width of the pulses that power the lamp during warm-up of the lamp; a high frequency oscillator; a DC to AC converter that converts current from the direct source to pulses of alternating current for powering the lamp, the converter comprising: at least one switch for gating current to the lamp; a switch control means, responsive to the high frequency oscillator, for controlling the switch and controlling the frequency of the alternating current pulses that power the lamp; current sensing means for sensing the current being supplied to the lamp; and current control means for limiting the current through the lamp to a predetermined safe level when the current sensed by the current sensing means exceeds a reference value.

Kuhnel, D.S.; Ottenstein, S.A.

1987-07-21T23:59:59.000Z

48

Hybrid electronic ballast operating the HPS lamp at constant power  

SciTech Connect

A hybrid solid-state ballast that operates high-pressure sodium (HPS) lamps at main frequency with constant power through rated life is described. The system utilizes two inductors connected in series and a bidirectional semiconductor switch connected in parallel to one of them. A lamp-starting circuit has also been included in the ballast. The static switch, with phase angle control provided by power feedback, actuates on lamp current compensating variations of the main voltage and increases of lamp arc voltage. The system offers the following: (1) increase of lamp life and system lumen maintenance; (2) power factor and total harmonic distortion of line current comparable to conventional lag ballast; and (3) operating cost savings, both in terms of energy cost and lamp replacement cost.

Kaiser, W. [Univ. de Sao Paulo (Brazil)

1998-03-01T23:59:59.000Z

49

Compact microwave lamp having a tuning block and a dielectric located in a lamp cavity  

DOE Patents (OSTI)

A microwave lamp having a compact structure utilizing a coupling slot which has a dielectric member extending therethrough and a tuning block adjoining the coupling slot. A non-conventional waveguide is used which has about the width of a WR-284 waveguide and about the length of a WR-340 waveguide.

Simpson, James E. (Gaithersburg, MD)

2000-01-01T23:59:59.000Z

50

LED LAMP OR BULB WITH REMOTE PHOSPHOR AND DIFFUSER ...  

An LED lamp or bulb is disclosed that comprises a light source, a heat sink structure and an optical cavity. The optical cavity comprises a phosphor ...

51

Heat transfer assembly for a fluorescent lamp and fixture  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure. 11 figs.

Siminovitch, M.J.; Rubenstein, F.M.; Whitman, R.E.

1992-12-29T23:59:59.000Z

52

Fluorescent lamp unit with magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp unit having a magnetic field generating means for improving the performance of the fluorescent lamp is disclosed. In a preferred embodiment the fluorescent lamp comprises four longitudinally extending leg portions disposed in substantially quadrangular columnar array and joined by three generally U-shaped portions disposed in different planes. In another embodiment of the invention the magnetic field generating means comprises a plurality of permanent magnets secured together to form a single columnar structure disposed within a centrally located region defined by the shape of lamp envelope. 4 figs.

Grossman, M.W.; George, W.A.

1989-08-08T23:59:59.000Z

53

Development and characterization of a high CRI LED lamp.  

E-Print Network (OSTI)

??The aim of this thesis is to realize a high CRI LED lamp using the color mixing technique. We start from a high efficiency white… (more)

Meneghesso , Matteo

2012-01-01T23:59:59.000Z

54

Stadiums and arenas use efficient, high wattage lamps - Today ...  

U.S. Energy Information Administration (EIA)

Other lighting types, such as light-emitting diode (LED), incandescent, and halogen lamps, are used in applications like signals, signage, ...

55

Heat transfer assembly for a fluorescent lamp and fixture  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure.

Siminovitch, Michael J. (Richmond, CA); Rubenstein, Francis M. (Berkeley, CA); Whitman, Richard E. (Richmond, CA)

1992-01-01T23:59:59.000Z

56

Fluorescent lamp with static magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed. 2 figs.

Moskowitz, P.E.; Maya, J.

1987-09-08T23:59:59.000Z

57

Convection venting lensed reflector-type compact fluorescent lamp system  

DOE Patents (OSTI)

Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures. 12 figs.

Pelton, B.A.; Siminovitch, M.

1997-07-29T23:59:59.000Z

58

Fluorescent lamp with static magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed.

Moskowitz, Philip E. (Peabody, MA); Maya, Jakob (Brookline, MA)

1987-01-01T23:59:59.000Z

59

An Electrical Cathode Model of a High Pressure Sodium Lamp  

Science Conference Proceedings (OSTI)

An electrical cathode model (ECM) of a high pressure sodium lamp (HPS) based on physical laws has been developed. The proposed ECM calculates the instantaneous voltage drop in a cathode sheath and the temperature distribution inside the cathode using ... Keywords: cathode model, HPS lamp ballast designs

Jose Luis Tapia; Joel O. Pacheco Sotelo; Eduardo Diaz Rodriguez; Yulia Nikolaevna Ledeneva; Rene Arnulfo Garcia Hernandez

2010-09-01T23:59:59.000Z

60

Convection venting lensed reflector-type compact fluorescent lamp system  

SciTech Connect

Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures.

Pelton, Bruce A. (825 Manor Rd., El Sobrante, CA 94803); Siminovitch, Michael (829 Manor Rd., El Sobrante, CA 94803)

1997-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

DEFINING THE EFFECTIVENESS OF UV LAMPS  

Office of Scientific and Technical Information (OSTI)

ARTI-21CR/610-40030-01 ARTI-21CR/610-40030-01 DEFINING THE EFFECTIVENESS OF UV LAMPS INSTALLED IN CIRCULATING AIR DUCTWORK Final Report Date Published - November 2002 Douglas VanOsdell and Karin Foarde RTI P.O. Box 12194 Research Triangle Park, NC 27709-2194 Prepared for the AIR-CONDITIONING AND REFRIGERATION TECHNOLOGY INSTITUTE 4100 N. Fairfax Drive, Suite 200, Arlington, Virginia 22203 Distribution A - Approved for public release; further dissemination unlimited. DISCLAIMER This report was prepared as an account of work sponsored by the Air-Conditioning and Refrigeration Technology Institute (ARTI) under its "HVAC&R Research for the 21 st Century" (21-CR) program. Neither ARTI, the financial supporters of the 21-CR program, or any agency

62

Contrast between the vertical and horizontal mercury discharge lamps  

SciTech Connect

This paper discusses the thermal behavior of a high pressure mercury lamp in a horizontal position, compared with that of a vertical lamp. The model adopted is three-dimensional, steady, and powered DC. After the model validation, we analyzed temperature fields and velocities for the case of the lamp in a horizontal position by comparing it with those of a lamp in vertical position. This setting initially fixed the wall temperature equal to 1000 K. However, the morphology of the temperature profile in the case of the horizontal lamp indicates that the temperature of the wall cannot be uniform. Thus, we have, in a second time, performed an energy balance at the wall to calculate its temperature. This aims to understand the influence of convection on the thermal properties of the source.

Ben Hamida, M. B.; Helali, H.; Araoud, Z.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, 5019 route de Kairouan Monastir (Tunisia)

2011-06-15T23:59:59.000Z

63

Effect of filament power removal on a fluorescent lamp system  

SciTech Connect

Two techniques are used to measure the effects of removing the filament power from a two-lamp, F-40, rapid-start fluorescent lamp system. The changes are measured for a standard CBM core-coil ballast and for a solid-state ballast operating the lamp at high frequency. There is a 4 tp 6% increase in system efficacy when the filament power is removed. Removal of filament power also decreases filament temperature from 1000/sup 0/C to below 700/sup 0/C in lamps operated at 60 Hz, and from above 600/sup 0/C to 300/sup 0/C in lamps operated at high frequency. The study shows that the arc current and anode fall also determine filament temperature.

Verderber, R.R.; Morse, O.; Rubinstein, F.M.

1985-07-01T23:59:59.000Z

64

Compatibility testing of fluorescent lamp and ballast systems  

SciTech Connect

The rapid growth in the use of electronic ballasts for fluorescent lighting systems, and the corresponding increase in the number of new products and new manufacturers in the market, has raised a number of questions regarding the compatibility of the lamps and ballasts used in fluorescent systems. Because many of the new products start and operate lamps differently than previous products, the relevant American National Standards Institute requirements may no longer be adequate for addressing compatibility concerns. The impacts on system performance of the newer products of a parametric study designed to test key hypotheses regarding the impact of ballast parameters on fluorescent lamp life. In this study, samples of 4-ft T8 fluorescent lamps were operated on duty cycles of 5 min on and 5 min off, using seven different ballast types. The results of the study indicate which parameters seem to have the biggest effect on lamp life, and can be used in establishing new performance standards for fluorescent systems.

Ji, Y.; Davis, R.; O' Rourke, C.; Chui, E.W.M.

1999-12-01T23:59:59.000Z

65

Max Tech and Beyond: High-Intensity Discharge Lamps  

Science Conference Proceedings (OSTI)

High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable operating conditions, and this necessitates additional power beyond that used by the lamp itself. HID lamps offer important advantages compared to other lighting technologies, making them well suited for certain applications. HID lamps can be very efficient, have long operating lives, are relatively temperature-insensitive and produce a large quantity of light from a small package. For these reasons, HID lamps are often used when high levels of illumination are required over large areas and where operating and maintenance costs must be kept to a minimum. Furthermore, if the installation has a significant mounting height, high-power HID lamps can offer superior optical performance luminaires, reducing the number of lamps required to illuminate a given area. The indoor environments best suited to HID lamps are those with high ceilings, such as those commonly found in industrial spaces, warehouses, large retail spaces, sports halls and large public areas. Research into efficacy improvements for HID lighting technologies has generally followed market demand for these lamps, which is in decline for MV and LPS, has reached a plateau for HPS and is growing for MH. Several manufacturers interviewed for this study indicated that although solid-state lighting was now receiving the bulk of their company's R&D investment, there are still strong HID lamp research programs, which concentrate on MH technologies, with some limited amount of investment in HPS for specific niche applications (e.g., agricultural greenhouses). LPS and MV lamps are no longer being researched or improved in terms of efficacy or other performance attributes, although some consider MH HID lamps to be the next-generation MV lamp. Thus, the efficacy values of commercially available MV, LPS and HPS lamps are not expected to increase in the next 5 to 10 years. MH lamps, and more specifically, ceramic MH lamps are continuing to improve in efficacy as well as light quality, manufacturability and lamp life. Within an HID lamp, the light-producing plasma must be heated to sufficiently high temperatures to achieve high efficiencie

Scholand, Michael

2012-04-01T23:59:59.000Z

66

The effects of fixture type and HVAC integration on fluorescent lamp/ballast performance  

SciTech Connect

This paper describes the effects of fixture type and lamp compartment air extract characteristics on lamp/ballast performance. A luminaire/plenum/HVAC simulator was used to measure minimum lamp wall temperature inside four fixture types while varying lamp-compartment extract conditions. Experimental data show that the lumen output of the lamp/ballast system varies by 20% and system efficacy by 10%, depending on the type of fixture and lamp-compartment extract technique employed.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.; Clark, T.A.

1986-06-01T23:59:59.000Z

67

Highly Efficient Small Form Factor LED Retrofit Lamp  

SciTech Connect

This report summarizes work to develop a high efficiency LED-based MR16 lamp downlight at OSRAM SYLVANIA under US Department of Energy contract DE-EE0000611. A new multichip LED package, electronic driver, and reflector optic were developed for these lamps. At steady-state, the lamp luminous flux was 409 lumens (lm), luminous efficacy of 87 lumens per watt (LPW), CRI (Ra) of 87, and R9 of 85 at a correlated color temperature (CCT) of 3285K. The LED alone achieved 120 lumens per watt efficacy and 600 lumen flux output at 25 C. The driver had 90% electrical conversion efficiency while maintaining excellent power quality with power factor >0.90 at a power of only 5 watts. Compared to similar existing MR16 lamps using LED sources, these lamps had much higher efficacy and color quality. The objective of this work was to demonstrate a LED-based MR16 retrofit lamp for replacement of 35W halogen MR16 lamps having (1) luminous flux of 500 lumens, (2) luminous efficacy of 100 lumens per watt, (3) beam angle less than 40{sup o} and center beam candlepower of at least 1000 candelas, and (4) excellent color quality.

Steven Allen; Fred Palmer; Ming Li

2011-09-11T23:59:59.000Z

68

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

An electrodeless microwave discharge lamp includes an envelope with a discharge forming fill disposed therein which emits light, the fill being capable of absorbing light at one wavelength and re-emitting the absorbed light at a different wavelength, the light emitted from the fill having a first spectral power distribution in the absence of reflection of light back into the fill, a source of microwave energy coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed within the microwave cavity and configured to reflect at least some of the light emitted by the fill back into the fill while allowing some light to exit, the exiting light having a second spectral power distribution with proportionately more light in the visible region as compared to the first spectral power distribution, wherein the light re-emitted by the fill is shifted in wavelength with respect to the absorbed light and the magnitude of the shift is in relation to an effective optical path length.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD)

2001-01-01T23:59:59.000Z

69

Covered Product Category: Compact Fluorescent Lamps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps October 7, 2013 - 10:48am Addthis ENERGY STAR Qualified Products Federal Energy Management Program (FEMP) provides acquisition guidance across a variety of product categories, including compact fluorescent lamps (CFLs), which are an ENERGY STAR-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR.

70

Information Resources: LED Replacements for Linear Fluorescent Lamps  

NLE Websites -- All DOE Office Websites (Extended Search)

Replacements for Linear Fluorescent Lamps Webcast Replacements for Linear Fluorescent Lamps Webcast In this June 20, 2011 webcast on LED products marketed as replacements for linear fluorescent lamps, Jason Tuenge of the Pacific Northwest National Laboratory (PNNL) discussed current Lighting Facts-listed products as well as products evaluated in the latest CALiPER reports. Eric Richman, also of PNNL, reported on a recently completed GATEWAY demonstration project, in which LED and fluorescent lamps were installed in a variety of recessed troffer luminaires for comparison in an office environment. The presentation concluded with a discussion of specifications listed in a newly updated technology fact sheet. View presentation slides View the text-alternative version View the webcast (WMV 16 MB) Download Windows Media Player

71

One piece microwave container screens for electrodeless lamps  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. Replacing mesh material by solid metal material as part of the screen unit significantly reduces leakage of microwave energy from the lamp. The solid section has multiple compliant fingers defined therein for engaging the periphery of a flange on the waveguide unit so that a hose clamp can easily secure the screen to the assembly. Screen units of this type having different mesh section configurations can be interchanged in the lamp assembly to produce different respective illumination patterns.

Turner, Brian (Myersville, MD); Ury, Michael (Bethesda, MD)

1998-01-01T23:59:59.000Z

72

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

the reason industry started by developing ceramic MH lampsceramic metal halide lamps, which are the focus of industry’industry had invested in the development of very low wattage ceramic

Scholand, Michael

2012-01-01T23:59:59.000Z

73

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network (OSTI)

button, a 100 watt (130 volt) lamp, a 100 watt long lifeFluorescent Watt L I ltage (volts) cu ge ic in s) ative ( 1the diode energy button (83 volts) was obtained by dividing

Verderber, Rudy

2013-01-01T23:59:59.000Z

74

The LAMP QPF Products. Part I: Model Development  

Science Conference Proceedings (OSTI)

The Local AWIPS (Advanced Weather Interactive Processing System) MOS (model output statistics) Program (LAMP) quantitative precipitation forecast (QPF) system produces 1–22-h forecasts of precipitation over the conterminous United States. The ...

Jerome P. Charba

1998-12-01T23:59:59.000Z

75

Electronic Radio-Frequency (Electrodeless) Induction Lamps: A Fluorescent Technology  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses an expanding energy efficient light source electronic radio-frequency (electrodeless) induction lamps. Business and technical market factors (Chapter 2) use the past and future growth of the CFL market to illustrate the potential for the induction lighting market while emphasizing future technical improvements. Discussion of the importance of utility involvement in helping their customers consider induction lamps for high-efficiency fluorescent applications with long-...

2007-12-20T23:59:59.000Z

76

An ultraviolet barrier-discharge OH molecular lamp  

Science Conference Proceedings (OSTI)

The energy and spectral parameters of a barrier discharge in a mixture of argon with hydroxyl {sup .}OH are studied experimentally. A sealed lamp with the radiation intensity maximum at {lambda} = 309.2 nm, an emitting surface area of {approx}700 cm{sup 2}, and a radiant excitance of 1.5 mW cm{sup -2} has been fabricated. The radiant power of the lamp is 1.1 W. (laser applications and other topics in quantum electronics)

Sosnin, E A; Erofeev, M V; Avdeev, S M; Panchenko, Aleksei N; Panarin, V A; Skakun, V S; Tarasenko, Viktor F; Shitts, D V [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

2006-10-31T23:59:59.000Z

77

Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry  

DOE Patents (OSTI)

A novel design is described for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment. 9 figs.

Siminovitch, M.

1998-02-10T23:59:59.000Z

78

Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry  

SciTech Connect

A novel design for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment.

Siminovitch, Michael (El Sobrante, CA)

1998-01-01T23:59:59.000Z

79

Studies on Temperature Dependence of Rubidium Lamp for Atomic Frequency Standard  

Science Conference Proceedings (OSTI)

Rb lamp is a very critical component of the Rb atomic clock's Physics Package. The Rb lamp's performance is very sensitive to temperature and its stability. In this paper we discuss the behaviors of Rb Lamp with temperature. The Rb lamp exciter power and temperature of Rb bulb are very important parameters in controlling the performance of the Rb Lamp. It is observed that at temperatures beyond 110 deg. C, the lamp mode changes from the ring to red mode resulting in abnormal broadening of emission lines and self reversal. The results of our studies on spectral analysis of Rb lamp under various operating conditions are reported in the paper.

Ghosal, Bikash; Banik, Alak; Vats, Vaibhav; Pal, Sukamal; Bahl, R. K [Space Applications Centre, ISRO, Ahmedabad-380015 (India)

2011-10-20T23:59:59.000Z

80

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

SciTech Connect

Lighting has been one of the fastest growing electric end-uses in China over the last twenty years, with an average annual growth rate of 14%. Fluorescent lighting provides a significant portion of China's lighting need. In 1998, China produced 680 million fluorescent lamps, of which 420 million were linear fluorescent lamps of various diameters (T8 to T12). There are substantial variations both in energy efficiency and lighting performance among locally produced fluorescent lamps. Such variations present a perfect opportunity for policy intervention through efficiency standards to promote the adoption of more efficient fluorescent lamps in China. This paper analyzes China's proposed minimum efficiency standard for fluorescent lamps and presents an assessment of its likely impacts on China's lighting energy consumption and GHG emissions.

Lin, Jiang

2002-04-11T23:59:59.000Z

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Very high efficacy electrodeless high intensity discharge lamps  

DOE Patents (OSTI)

An electrodeless arc lamp comprises an outer jacket hermetically sealing and thermally protecting an arc tube inside which has an upwardly convex bottom center section. The absence of chemically reactive electrode material makes it possible to use metal halides other than iodides. The tube contains chlorides, bromides or a mixture thereof of scandium and sodium in a nearly equimolar relationship in addition to mercury and an inert gas. Good color balance can be obtained at reduced reservoir temperature and with less power loss. Reduction in wall temperature makes it possible to attain longer lamp life.

Johnson, P.D.

1985-10-03T23:59:59.000Z

82

New LED light sources and lamps for general illumination  

E-Print Network (OSTI)

of light source compared to traditional light sources like incandescent bulbs and fluorescent tubes bulb. LEDs emit colored light with a narrow spectral band of 20-30 nm, colors covering the spectralNew LED light sources and lamps for general illumination Carsten Dam-Hansen, Birgitte Thestrup

83

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry  

NLE Websites -- All DOE Office Websites (Extended Search)

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry Speaker(s): Francis Rubinstein Date: February 14, 2008 - 12:00pm Location: 90-3122 Fluorescent lamp ballasts are subject to DOE appliance standards and rulemaking. But currently, only ballasts for older fluorescent lamp types, such as T-12 lamps are subject to minimum efficacy limits. The majority of fluorescent lamps now being shipped (T-8 and T-5 types) type are operated by ballasts that will not be subject to DOE rule until 2011. The metric used by DOE for characterizing the electrical efficiency of the fluorescent lamp-ballast system is called Ballast Efficacy Factor (BEF). Because BEF is not normalized, it is of limited utility for rulemaking and is useless for procurement. But by normalizing BEF to the total lamp power, I have

84

Solid-State Lighting: LED Replacement Lamps: Current Performance and the  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Replacement Lamps: Current LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® to someone by E-mail Share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Facebook Tweet about Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Twitter Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Google Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Delicious Rank Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Digg Find More places to share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on

85

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

E-Print Network (OSTI)

the economics of fuel-based and LED lighting technology fordata logger equipped rechargeable LED lamps, monitoring theadoption of the LED lamps, and a follow-up survey. 1 Figure

Johnstone, Peter

2009-01-01T23:59:59.000Z

86

Information on the Fate of Mercury From Fluorescent Lamps Disposed in Landfills  

Science Conference Proceedings (OSTI)

Mercury is contained in energy-efficient fluorescent, mercury-vapor, metal halide, and high-pressure sodium lamps. This report presents information on the potential for air and groundwater contamination when mercury lamps are disposed in municipal landfills.

1995-04-19T23:59:59.000Z

87

Performance of electronic ballasts and other new lighting equipment: (Phase 2, The 34-watt F40 rapid start T-12 fluorescent lamp): Final report  

SciTech Connect

This study has measured the performance of energy-saving 34-watt F40, T-12, rapid-start, lite white fluorescent lamps being operated by solid-state ballasts and lighting control equipment. The performances of these lamp systems are compared with those of 40-watt F40, T-12 rapid-start cool white fluorescent lamp systems studied in the prior phase of this project. With the 34-watt F40 lamps and various solid-state ballasts, system efficacy ranged from 67 to 84 lumens per watt and ballast factor from 0.756 to 0.908. Average system efficacy using the 34-watt lamps exceeded that of systems using 40-watt lamps and the same solid-state ballasts by only 1 percent even though the 34-watt lamps is about 6 percent more efficacious than the 40-watt lamp. This apparent discrepancy is due to increased ballast losses when operating the 34-watt lamps. However, the systems efficacy of the 34-watt lamps used with a solid-state ballast exceeded that of a 34-watt, two-lamp system using the standard core-coil ballast by as much as 29 percent. A T-8 fluorescent lamp system with a smaller lamp diameter was also included in the study. Operating this lamp with a solid-state ballast produced a high system efficacy of 90 lumens per watt, a 39 percent improvement over the efficacy of a 40-watt F40 system using the standard core-coil ballast. The use of static controllers with 34-watt F40 lamps can result in excessive flickering (46 percent) and the generation of a second harmonic as high as 96 percent of the fundamental frequency. The dynamic controllers, when used to dim the 34-watt lamps generally cannot be dimmed as low as the 40-watt lamp system without flickering. In general, the 34-watt energy-saving lamps are appropriate as a retrofit to reduce illumination levels. However, for new construction, the 40-watt F40 argon filled lamps cost less, perform better, and provide a more reliable system. 5 refs., 27 figs., 9 tabs.

Verderber, R.R.; Morse, O.

1988-02-01T23:59:59.000Z

88

Energy Performance and Emissions of Electronic Ballasts Powering 4-Foot Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the Worcester Polytechnic Institute, in contract with the EPRI Power Electronics Applications Center (PEAC) to determine the average efficacy (lumens per watt), displacement power factor, total power factor, and current harmonic distortion of modern electronic ballasts powering fluorescent lamps.

2003-12-31T23:59:59.000Z

89

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and  

E-Print Network (OSTI)

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium light tubes are recycled. They are made from aluminum and metal. Aluminum is a silver-white metal and is very light in weight and strong. Because aluminum is ductile, it can be drawn into wires or pressed

Ungerleider, Leslie G.

90

Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface.

Siminovitch, Michael J. (Richmond, CA)

1992-01-01T23:59:59.000Z

91

Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface. 12 figs.

Siminovitch, M.J.

1992-11-10T23:59:59.000Z

92

Inrush related problems caused by lamps with electronic drivers and their mitigation  

Science Conference Proceedings (OSTI)

New types of appliances sometimes bring unexpected power quality problems. On several locations it was reported that energy-saving lamps cause random false tripping of circuit breakers. In all of these cases these lamps had electronic drivers. An investigation ... Keywords: energy-saving lamp, false tripping, inrush, mitigation, power quality

Vladimir ?uk; Joseph F. G. Cobben; Wil L. Kling

2011-07-01T23:59:59.000Z

93

Sulfur Lamps-The Next Generation of Efficient Light?  

NLE Websites -- All DOE Office Websites (Extended Search)

5 5 Sulfur Lamps-The Next Generation of Efficient Light? The figure above is a schematic of the system installed at the National Air and Space Museum and the DOE headquarters in Washington, D.C., Light from the sulfur lamp is focused by a parabolic reflector so that it enters the light pipe within a small angular cone. Light travels down the pipe, reflecting off the prismatic film (A) that lines the outer acrylic tube. The prismatic film reflects the light through total internal reflection (C), an intrinsically efficient process. Some of the light striking the film (at A) is not reflected and "leaks out" of the pipe walls (B), giving the pipe a glowing appearance. A light ray that travels all the way down the pipe will strike the mirror at the end (D) and return back up the pipe.

94

L Prize Competition Winner 60W Incandesent Replacement Lamp Update  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Technology Deployment Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International May 23, 2012 Philips Wins First L Prize 2 * August 3, 2011: Philips announced as winner of 60W replacement bulb category * Product distributed thru commercial and retail channels Image courtesy of Philips -...[O]nce an award is made the authorizing Act directs General Services Administration to develop federal purchasing schedules for solid-state lamps that meet or exceed the specifications laid out in the prize category-so long as it is cost effective. I hope the GSA begins this process soon.‖

95

Miniature UV lamp excited by subnanosecond voltage pulses  

SciTech Connect

Energy, time, and spectral characteristics of emission of the second positive system of N{sub 2} molecules in gaseous nitrogen, Ar - N{sub 2} mixture, and air are investigated. An FPG-10 generator with voltage pulse FWHM of 200 and 400 ps and matched-load amplitudes of 14 and 6 kV, respectively, is used to excite gases. It is shown that excitation can be performed in two regimes using this generator. In the first regime a diffuse discharge is formed at atmospheric pressure, which opens ways to design miniature nanosecond UV lamps. A diffuse discharge is formed due to the generation of runaway electrons, with the aid of electrodes having a small radius of curvature and voltage pulses with a sharp leading edge. In the second regime an elevated average radiation power is obtained under excitation by a barrier discharge. However, the operating pressure is lower in this case, and the sizes of the emitting region and the UV pulse width significantly increase. (laser applications and other topics in quantum electronics)

Erofeev, M V; Baksht, E Kh; Tarasenko, Viktor F; Shut'ko, Yu V [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

2010-08-27T23:59:59.000Z

96

DuraLamp USA: Proposed Penalty (2010-CE-0912) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) September 9, 2010 DOE alleged in a Notice of Proposed Civil Penalty that DuraLamp USA, Inc. failed to certify a variety of general service fluorescent lamps as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. DuraLamp USA: Proposed Penalty (2010-CE-0912) More Documents & Publications DuraLamp USA: Order (2010-CE-0912)

97

Energy-efficient compact screw-in fluorescent lamp. Final report  

SciTech Connect

A compact fluorescent lamp has been designed and constructed which can replace an incandescent lamp. The lamp is slightly larger than a standard lamp (8 3/4 in. x 3 1/4 in.), but is designed to fit a majority of portable lamp applications. This version, with a core-coil ballast, results in a system efficacy of 54 lumens per watt, with a light output of more than 1800 lumens. This compares favorably with a 100-watt incandescent (17.5 lumens per watt and 1750 lumens light output). The color temperature of 3000/sup 0/K is compatible with an incandescent lamp (2800/sup 0/K). The color rendition index (CRI) is 84. With a solid-state ballast, the efficacy and light output could be increased by 20% (65 l/w, 2200 lumens) and could provide a direct replacement for a three-way, 150-watt incandescent lamp (15 l/w, 2200 lumens).

Morton, E.W.

1982-11-01T23:59:59.000Z

98

Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps CALiPER Benchmark Report  

Science Conference Proceedings (OSTI)

The Department of Energy (DOE) Commercially Available LED Product Evaluation and Reporting (CALiPER) Program was established in 2006 to investigate the performance of light-emitting diode (LED) based luminaires and replacement lamps. To help users better compare LED products with conventional lighting technologies, CALiPER has also performed benchmark research and testing of traditional (i.e., non-LED) lamps and fixtures. This benchmark report addresses standard 4-foot fluorescent lamps (i.e., T12 and T8) and the 2-foot by 4-foot recessed troffers in which they are commonly used. This report also examines available LED replacements for T12 and T8 fluorescent lamps, and their application in fluorescent troffers. The construction and operation of linear fluorescent lamps and troffers are discussed, as well as fluorescent lamp and fixture performance, based on manufacturer data and CALiPER benchmark testing. In addition, the report describes LED replacements for linear fluorescent lamps, and compares their bare lamp and in situ performance with fluorescent benchmarks on a range of standard lighting measures, including power usage, light output and distribution, efficacy, correlated color temperature, and the color rendering index. Potential performance and application issues indicated by CALiPER testing results are also examined.

Myer, Michael; Paget, Maria L.; Lingard, Robert D.

2009-01-16T23:59:59.000Z

99

Conservation potential of compact fluorescent lamps in India and Brazil  

SciTech Connect

We evaluate the conservation potential of compact fluorescent lamps (CFLs) for managing the rapidly increasing electrical energy and peak demand in India and Brazil. Using very conservative assumptions, we find that the cost of conserved energy using 16 W CFLs is 4 and 6 times less than the long range marginal cost of electricity for the two countries. The cost of avoided peak installed capacity is 6 and 9.5 times less than the cost of new installed capacity for India and Brazil. The analysis is undertaken from the three separate perspectives of the national economies, the consumers, and the utilities. We find that because residential electricity is subsidized, the consumers have little or no incentive to purchase and install the CFLs, unless they too are subsidized. However, the benefits of CFL installation to the utility are so large that subsidizing them is a paying proposition for the utility are so large that subsidizing them is a paying proposition for the utility in almost all cases. As an illustration of a gradual introduction strategy for CFLs, we calculate a scenario where national savings of the order of US $1.2 million per day for India and US $2.5 million per day for Brazil are reached in 10 years by a small and gradual transfer of subsidy from residential electricity to CFLs. We then explore the barriers to immediate large scale introduction of these lamps in the two countries. Specific technical and marketing problems are identified and discussed, which would require solution before such an introduction can be attempted. Lastly, we discuss the range of policy instruments, in addition to a subsidy scheme, that can be used for promoting the diffusion of these lamps in the domestic and commercial sector. 47 refs., 15 figs., 2 tabs.

Gadgil, A.; Martino Jannuzzi, G. de (Lawrence Berkeley Lab., CA (USA); Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia)

1989-07-01T23:59:59.000Z

100

Energy efficiency lighting on board naval ships: Phase 2 (The T-8 lamp system)  

SciTech Connect

This report describes the development and performance of the T-8 fluorescent lamp-ballast system. Similar to the Phase I effort, the cooperation of the lamp and ballast companies (GTE, North American Philips Lighting, and IOTA Engineering) were required for the successful result. The above companies submitted prototype lamps and ballasts to the Lawrence Berkeley Laboratory Lighting Group to evaluate. The lamp designs were modified as required and the optimum system selected. Two-lamp designs and one ballast were chosen and tested to determine if they met the Navy specifications. The second section describes the lamp-ballast specifications. This section includes the measured thermal performance from an ambient of 10/degree/C to 60/degree/C. 1 ref., 8 figs., 11 tabs.

Verderber, R.R.

1987-01-31T23:59:59.000Z

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Microwave lamp with multi-purpose rotary motor  

DOE Patents (OSTI)

In a microwave powered electrodeless lamp, a single rotary motor is used to (a) rotate the bulb and (b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooler for providing cooling gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement. 8 figs.

Ury, M.G.; Turner, B.; Wooten, R.D.

1999-02-02T23:59:59.000Z

102

Microwave lamp with multi-purpose rotary motor  

DOE Patents (OSTI)

In a microwave powered electrodeless lamp, a single rotary motor is used to a) rotate the bulb and b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooling for providing cooler gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement.

Ury, Michael G. (Bethesda, MD); Turner, Brian (Myersville, MD); Wooten, Robert D. (Rockville, MD)

1999-01-01T23:59:59.000Z

103

Low pressure arc discharge lamp apparatus with magnetic field generating means  

DOE Patents (OSTI)

A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25 C. 3 figs.

Grossman, M.W.; George, W.A.; Maya, J.

1987-10-06T23:59:59.000Z

104

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

E-Print Network (OSTI)

for Small Businesses in Kenya." Lumina Project Technicalfor Night Market Vendors in Kenya who use LED Lamps Petermany people and businesses in Kenya who participated in this

Johnstone, Peter

2009-01-01T23:59:59.000Z

105

Demonstration of LED Retrofit Lamps at the Smithsonian American Art Museum, Washington, DC  

Science Conference Proceedings (OSTI)

This report documents observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy GATEWAY Solid-State Lighting (SSL) Technology Demonstration Program at the Smithsonain American Art Museum in Washington, DC. LED Lamp samples were tested in the museum workshop, temporarily installed in a gallery for feedback, and ultimately replaced all traditional incandescent lamps in one gallery of modernist art at the American Art Museum and partially replacing lamps in two galleries at the Musesum's Renwick Gallery. This report describes the selection and testing process, technology challenges, perceptions, economics, energy use, and mixed results of usign LED replacement lamps in art galleries housing national treasures.

Miller, Naomi J.; Rosenfeld, Scott M.

2012-06-22T23:59:59.000Z

106

Guidance Concerning Enforcement of EISA 2007 Standards Candelabra Base and Intermediate Base Lamps  

Energy.gov (U.S. Department of Energy (DOE))

The Energy Independence and Security Act of 2007 (EISA 2007) imposed energy conservation standards for candelabra and intermediate base lamps, and those provisions became effective with the statute.

107

EA-1911: Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps  

Energy.gov (U.S. Department of Energy (DOE))

This EA will evaluate the environmental impacts of a proposal to amend energy conservation standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps.

108

Dimming of Compact Fluorescent Lamps Caused By Cold-Air Drafts  

Science Conference Proceedings (OSTI)

This Case Study documents the investigation performed by the New York Port Authority (PA) of the dimming of compact fluorescent lamps (CFLs) in the World Trade Center.

2003-12-31T23:59:59.000Z

109

Power control architectures for cold cathode fluorescent lamp and light emitting diode based light sources.  

E-Print Network (OSTI)

?? In this dissertation, two different energy efficient power supply topologies are introduced for controlling cold cathode fluorescent lamp (CCFL) and high-brightness light emitting diode… (more)

Doshi, Montu V.

2010-01-01T23:59:59.000Z

110

A new optimized fluorescent lamp and ballast for low-energy general lighting applications  

SciTech Connect

A new fluorescent lamp and ballast system has been developed which minimizes system input power while maintaining light output close to values provided by conventional lamps and ballasts. The 28-WT-12 lamp designed for the new system utilizes a redesigned electrode structure which allows the lamp to be started in the rapid start manner but operated in an instant start mode to maximize the discharge efficacy (lumens/watt) while reducing lamp cathode power requirements. A matching two-lamp ballast incorporates a solid-state switching device to turn off the cathode heating circuit automatically once the lamps have started. Both lamps and ballasts are physically interchangeable with conventional equipment so that existing luminaires can be converted without luminaire, lampholder, and wiring modifications. This new lamp/ballast system can achieve efficacy values exceeding 80 lm/W--more than 25 percent better than the performance of conventional fluorescent systems of the early 1970's-along with the excellent life and reliability characteristics typical of electromagnetically ballasted systems. Economic analyses indicate that the new system is appropriate for many new commercial general lighting installations, although it is particularly suitable as a retrofit system for installations where power reductions are essential but where conversion costs must be minimized and illumination levels preserved.

Hammer, E.E.; McGowan, T.K.

1983-07-01T23:59:59.000Z

111

The effects of supply harmonics on the performance of compact fluorescent lamps  

SciTech Connect

This paper describes a performance evaluation of ten compact fluorescent lighting systems operated with sinusoidal and distorted voltage waveform conditions. The lamps were either provided with an electronic ballast, a magnetic core ballast or a magnetic core ballast with a power factor correction circuit. The test results show that the electrical performance of the compact fluorescent lamps for both sinusoidal and distorted voltage waveform operation is related to the different types of ballast used. The cost of operation of these compact fluorescent lamps was calculated and compared to the cost of a conventional 60 W incandescent lamp.

Arseneau, R.; Ouellette, M.

1993-04-01T23:59:59.000Z

112

High Efficiency LED Lamp for Solid-State Lighting  

SciTech Connect

This report contains a summary of technical achievements during a three-year project to demonstrate high efficiency, solid-state lamps based on gallium nitride/silicon carbide light-emitting diodes. Novel chip designs and fabrication processes are described for a new type of nitride light-emitting diode with the potential for very high efficiency. This work resulted in the demonstration of blue light-emitting diodes in the one watt class that achieved up to 495 mW of light output at 350 mA drive current, corresponding to quantum and wall plug efficiencies of 51% and 45%, respectively. When combined with a phosphor in Cree's 7090 XLamp package, these advanced blue-emitting devices resulted in white light-emitting diodes whose efficacy exceeded 85 lumens per watt. In addition, up to 1040 lumens at greater than 85 lumens per watt was achieved by combining multiple devices to make a compact white lamp module with high optical efficiency.

James Ibbetson

2006-12-31T23:59:59.000Z

113

Spectral irradiance model for tungsten halogen lamps in 340-850 nm wavelength range  

Science Conference Proceedings (OSTI)

We have developed a physical model for the spectral irradiance of 1 kW tungsten halogen incandescent lamps for the wavelength range 340-850 nm. The model consists of the Planck's radiation law, published values for the emissivity of tungsten, and a residual spectral correction function taking into account unknown factors of the lamp. The correction function was determined by measuring the spectra of a 1000 W, quartz-halogen, tungsten coiled filament (FEL) lamp at different temperatures. The new model was tested with lamps of types FEL and 1000 W, 120 V quartz halogen (DXW). Comparisons with measurements of two national standards laboratories indicate that the model can account for the spectral irradiance values of lamps with an agreement better than 1% throughout the spectral region studied. We further demonstrate that the spectral irradiance of a lamp can be predicted with an expanded uncertainty of 2.6% if the color temperature and illuminance values for the lamp are known with expanded uncertainties of 20 K and 2%, respectively. In addition, it is suggested that the spectral irradiance may be derived from resistance measurements of the filament with lamp on and off.

Ojanen, Maija; Kaerhae, Petri; Ikonen, Erkki

2010-02-10T23:59:59.000Z

114

Table lamp with dynamically controlled lighting distribution and uniformly illuminated luminous shade  

DOE Patents (OSTI)

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) or other lamps arranged vertically, i.e. one lamp above the other, with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum ensures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. In a particular configuration, the reflective septum is bowl shaped, with the upper CFL sitting in the bowl, and a luminous shade hanging down from the bowl. The lower CFL provides both task lighting and uniform shade luminance. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. However, other types of lamps, including incandescent, halogen, and LEDs can also be used in the fixture. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2002-01-01T23:59:59.000Z

115

Research on Active Power Factor Correction of the Electronic Ballast for High-Pressure Sodium Lamps Based on L6563  

Science Conference Proceedings (OSTI)

In the recent years, there has been a growing interest in the design of high-pressure sodium lamp electronic ballast. Two measures are proposed to improve the power factor of high-pressure sodium lamp electronic ballasts from the definition of harmonic ... Keywords: high-pressure sodium lamps, electronic ballast, active power factor correction, L6563

Sun Jing

2010-06-01T23:59:59.000Z

116

Lamp system with conditioned water coolant and diffuse reflector of polytetrafluorethylene(PTFE)  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

1999-01-01T23:59:59.000Z

117

Lamp system with conditioned water coolant and diffuse reflector of polytetrafluorethylene(PTFE)  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO{sub 2}) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, L.E.; Hackel, L.

1999-10-26T23:59:59.000Z

118

Identification of lamp ballasts containing PCBs. Revised edition. Report no. EPS 2/CC/2  

SciTech Connect

Fluorescent lamp ballast capacitors are among the products that may contain polychlorinated biphenyls (PCBs). Questions about lamp ballasts concern the potential for leakage, the risk of heating and exploding, how to identify a ballast which contains PCBs, and the risk to human health. This study identifies those ballasts containing PCB-filled capacitors; the domestic and foreign manufacturers of PCB-containing ballasts; the total quantity of PCBs used in ballasts; and any potential problems. The study does not identify the risks of human health arising from the use of PCB-ballasts in fluorescent lamps.

1991-01-01T23:59:59.000Z

119

Integrated starting and running amalgam assembly for an electrodeless fluorescent lamp  

DOE Patents (OSTI)

An integrated starting and running amalgam assembly for an electrodeless SEF fluorescent lamp includes a wire mesh amalgam support constructed to jointly optimize positions of a starting amalgam and a running amalgam in the lamp, thereby optimizing mercury vapor pressure in the lamp during both starting and steady-state operation in order to rapidly achieve and maintain high light output. The wire mesh amalgam support is constructed to support the starting amalgam toward one end thereof and the running amalgam toward the other end thereof, and the wire mesh is rolled for friction-fitting within the exhaust tube of the lamp. The positions of the starting and running amalgams on the wire mesh are jointly optimized such that high light output is achieved quickly and maintained, while avoiding any significant reduction in light output between starting and running operation.

Borowiec, Joseph Christopher (Schenectady, NY); Cocoma, John Paul (Clifton Park, NY); Roberts, Victor David (Burnt Hills, NY)

1998-01-01T23:59:59.000Z

120

On the Brightness of the Thomson Lamp: A Prolegomenon to Quantum Recursion Theory  

Science Conference Proceedings (OSTI)

Some physical aspects related to the limit operations of the Thomson lamp are discussed. Regardless of the formally unbounded and even infinite number of "steps" involved, the physical limit has an operational meaning in agreement with the Abel sums ...

Karl Svozil

2009-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

The Jamming point street-lamp in the world of granular media  

E-Print Network (OSTI)

The Jamming of soft spheres at zero temperature, the J-point, has been extensively studied both numerically and theoretically and can now be considered as a safe location in the space of models, where a street lamp has been lit up. However, a recent work by Ikeda et al, 2013 reveals that, in the Temperature/Packing fraction parameter space, experiments on colloids are actually rather far away from the scaling regime illuminated by this lamp. Is it that the J-point has little to say about real system? What about granular media? Such a-thermal, frictional, systems are a-priori even further away from the idealized case of thermal soft spheres. In the past ten years, we have systematically investigated horizontally shaken grains in the vicinity of the Jamming transition. We discuss the above issue in the light of very recent experimental results. First, we demonstrate that the contact network exhibits a remarkable dynamics, with strong heterogeneities, which are maximum at a packing fraction phi star, distinct and smaller than the packing fraction phi dagger, where the average number of contact per particle starts to increase. The two cross-overs converge at point J in the zero mechanical excitation limit. Second, a careful analysis of the dynamics on time scales ranging from a minute fraction of the vibration cycle to several thousands of cycles allows us to map the behaviors of this shaken granular system onto those observed for thermal soft spheres and demonstrate that some light of the J-point street-lamp indeed reaches the granular universe.

Corentin Coulais; Robert P. Behringer; Olivier Dauchot

2013-05-03T23:59:59.000Z

122

Demonstration of LED Retrofit Lamps at the Jordan Schnitzer Museum of Art  

SciTech Connect

The Jordan Schnitzer Museum of Art in Eugene, Oregon, houses a remarkable permanent collection of Asian art and antiquities, modern art, and sculpture, and also hosts traveling exhibitions. In the winter and spring of 2011, a series of digital photographs by artist Chris Jordan, titled "Running the Numbers," was exhibited in the Coeta and Donald Barker Special Exhibitions Gallery. These works graphically illustrate waste (energy, money, health, consumer objects, etc.) in contemporary culture. The Bonneville Power Administration and the Eugene Water and Electricity Board provided a set of Cree 12W light-emitting diode (LED) PAR38 replacement lamps (Cree LRP38) for the museum to test for accent lighting in lieu of their standard Sylvania 90W PAR38 130V Narrow Flood lamps (which draw 78.9W at 120V). At the same time, the museum tested LED replacement lamps from three other manufacturers, and chose the Cree lamp as the most versatile and most appropriate color product for this exhibit. The lamps were installed for the opening of the show in January 2011. This report describes the process for the demonstration, the energy and economic results, and results of a survey of the museum staff and gallery visitors on four similar clusters of art lighted separately by four PAR38 lamps.

Miller, Naomi J.

2011-09-01T23:59:59.000Z

123

X-ray Methods in High-Intensity Discharges and Metal-Halide Lamps: X-ray Induced Fluorescence  

SciTech Connect

We describe the use of x-ray induced fluorescence to study metal-halide high-intensity discharge lamps and to measure equilibrium vapor pressures of metal-halide salts. The physical principles of metal-halide lamps, relevant aspects of x-ray-atom interactions, the experimental method using synchrotron radiation, and x-ray induced fluorescence measurements relevant to metal-halide lamps are covered.

Curry, John J.; Lapatovich, Walter P.; Henins, Albert (NIST)

2011-12-09T23:59:59.000Z

124

Determination of the cathode and anode voltage drops in high power low-pressure amalgam lamps  

Science Conference Proceedings (OSTI)

For the first time, cathode and anode drops of powerful low-pressure amalgam lamps were measured. The lamp discharge current is 3.2 A, discharge current frequency is 43 kHz, linear electric power is 2.4 W/cm. The method of determination of a cathode drop is based on the change of a lamp operating voltage at variation of the electrode filament current at constant discharge current. The total (cathode plus anode) drop of voltage was measured by other, independent ways. The maximum cathode fall is 10.8 V; the anode fall corresponding to the maximal cathode fall is 2.4 V. It is shown that in powerful low pressure amalgam lamps the anode fall makes a considerable contribution (in certain cases, the basic one) to heating of electrodes. Therefore, the anode fall cannot be neglected, at design an electrode and ballast of amalgam lamps with operating discharge current frequency of tens of kHz.

Vasilyak, L. M., E-mail: vasilyak@ihed.ras.ru [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation); Vasiliev, A. I., E-mail: vasiliev@npo.lit.ru; Kostyuchenko, S. V.; Sokolov, D. V.; Startsev, A. Yu. [Joint Stock Company NPO LIT (Russian Federation); Kudryavtsev, N. N. [Moscow Institute of Physics and Technology (State University) (Russian Federation)

2011-12-15T23:59:59.000Z

125

Energy-Efficient, High-Color-Rendering LED Lamps Using Oxyfluoride and Fluoride Phosphors  

Science Conference Proceedings (OSTI)

LED lamps using phosphor downconversion can be designed to replace incandescent or halogen sources with a 'warm-white' correlated color temperature (CCT) of 2700-3200 K and a color rendering index (CRI) greater than 90. However, these lamps have efficacies of {approx}70% of standard 'cool-white' LED packages (CCT = 4500-6000 K; CRI = 75-80). In this report, we describe structural and luminescence properties of fluoride and oxyfluoride phosphors, specifically a (Sr,Ca){sub 3}(Al,Si)O{sub 4}(F,O):Ce{sup 3+} yellow-green phosphor and a K{sub 2}TiF{sub 6}:Mn{sup 4+} red phosphor, that can reduce this gap and therefore meet the spectral and efficiency requirements for high-efficacy LED lighting. LED lamps with a warm-white color temperature (3088 K), high CRI (90), and an efficacy of {approx}82 lm/W are demonstrated using these phosphors. This efficacy is {approx}85% of comparable cool-white lamps using typical Y{sub 3}Al{sub 5}O{sub 12}:Ce{sup 3+}-based phosphors, significantly reducing the efficacy gap between warm-white and cool-white LED lamps that use phosphor downconversion.

Setlur, A.; Radkov, E; Henderson, C; Her, J; Srivastava, A; Karkada, N; Kishore, M; Kumar, N; Aesram, D; et al.

2010-01-01T23:59:59.000Z

126

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

127

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

NLE Websites -- All DOE Office Websites (Extended Search)

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

128

Magical Mystery Devices or Not: How do LED Lamps and Luminaires Really Measure-Up?  

SciTech Connect

Solid-state lighting products for general lighting applications are now gaining a market presence, and more and more people are asking, “Which of these are ‘good’ products? Do they perform as claimed? How do they compare? Light Emitting Diodes (LEDs) differ from other light sources enough to require new procedures for measuring their performance and comparing to other lighting options, so both manufacturers and buyers are facing a learning curve. The energy-efficiency community has traditionally compared light sources based on system efficacy: rated lamp lumens divided by power into the system. This doesn’t work for LEDs because there are no standard LED “lamp” packages and no lamp ratings, and because LED performance depends heavily on thermal, electrical, and optical design of complete lighting unit or ‘luminaire’. Luminaire efficacy is the preferred metric for LEDs because it measures the net light output from the luminaire divided by power into the system.

Paget, Maria L.; McCullough, Jeffrey J.; Steward, Heidi E.

2008-08-15T23:59:59.000Z

129

Selecting effective fluorescent lamp and ballast for retrofit in the continental United States. Final report  

SciTech Connect

Electrical lighting is a major contributor to daytime peak energy demand, accounting for about 30 percent of total electricity consumption in most Army facilities. Some of this energy may be wasted because many existing lighting systems at Army Installations use outmoded technologies. While recent technology has improved the energy efficiency of all lighting systems, fluorescent lighting-the most widely used interior building lighting-has shown the greatest efficiency gains. Retrofits using high-efficiency fluorescent lamps and ballasts can yield significant operating cost savings. High-efficiency fluorescent lighting systems are widely available, but current information on their performance characteristics is highly technical and not easily accessible to Army facility managers considering retrofit options. This report provides a single, accessible source that summarizes fluorescent lamp and ballast performance characteristics and outlines selection procedures. Fluorescent lamp, Retrofit, Ballast, Lighting. Energy conservation.

Taylor, W.R.

1993-08-01T23:59:59.000Z

130

Spectral distribution of dimmed HID lamps in a plant growth facility  

SciTech Connect

A commercial dimming ballast system for high intensity discharge (HID) lamps has been tested for use in plant growth chambers. The dimming ballast system can be controlled either manually at the dimming panel or by a d.c. voltage from a programmer or computer. Using the dimming system, photosynthetically active radiation can be continuously varied from about 200 to about 2000 ..mu..E m/sup -2/s/sup -1/. This paper shows the effects of dimming on the spectral intensity (400 to 750 nm) of three types of HID lamps measured individually and in combination to achieve a better spectral mix. The lamps used in this study were 400 w metal halide, mercury vapor and high pressure sodium.

Bingham, G.E.; Coyne, P.I.

1979-05-01T23:59:59.000Z

131

Nature of the effect of the ballast volumes of flash lamps on their emission  

SciTech Connect

The cause of the decrease in laser efficiency during pumping by flash lamps with increased ballast volumes is the unproductive loss of radiation, originating from the ballast volumes, and the associated change in the radiation brightness distribution along the length of the lamp. The increase radiation brightness at the electrodes of the light source is not the result of constriction of the discharge or the luminescence of the electrode plasma erosion, but is due to the slowing down of the plasma flows by the surface of the electrodes and to the slowing down of the ionized gas moving from the ballast volumes when it meets the denser plasma of the discharge zone. The profile of the current lines at the electrodes is established and the frequency of the axial oscillations of the plasma in the lamp is determined.

Basov, Yu.G.; Makarov, V.N.; Narkhova, G.I.

1975-11-01T23:59:59.000Z

132

Potential Environmental Impacts from the Metals in Incandescent, Compact Fluorescent Lamp (CFL), and Light-Emitting Diode (LED)  

E-Print Network (OSTI)

), and Light-Emitting Diode (LED) Bulbs Seong-Rin Lim, Daniel Kang, Oladele A. Ogunseitan,,§ and Julie M sources with compact fluorescent lamp (CFL) and light-emitting diode (LED) bulbs that use about 70% and 85 lighting systems are transitioning from incandes- cent to compact fluorescent lamp (CFL) and light

Short, Daniel

133

High frequency transformerless electronics ballast using double inductor-capacitor resonant power conversion for gas discharge lamps  

SciTech Connect

A novel high frequency LCLC double resonant electronic ballast has been developed for gas discharge lamp applications. The ballast consists of a half-bridge inverter which switches at zero voltage crossing and an LCLC resonant circuit which converts a low ac voltage to a high ac voltage. The LCLC resonant circuit has two LC stages. The first LC stage produces a high voltage before the lamp is ignited. The second LC stage limits lamp current with the circuit inductance after the lamp is ignited. In another embodiment a filament power supply is provided for soft start up and for dimming the lamp. The filament power supply is a secondary of the second resonant inductor. 27 figs.

Lai, J.S.

1995-06-20T23:59:59.000Z

134

15 KJ FLASH LAMP, POWER CONDITIONING UNIT DESIGNED FOR SAFTY, RELIABILITY & MANUFACTURABILITY*  

SciTech Connect

A 15kJoule, Flash Lamp Power Conditioning Unit has been successfully designed, developed, and deployed in the National Ignition Facility (NIF) Preamplifier Modules (PAM). The primary design philosophy of this power conditioning unit (PCU) is safety, reliability, and manufacturability. Cost reduction over commercially equivalent systems was also achieved through an easily manufactured packaging design optimized to meet NIF requirements. While still maintaining low cost, the PCU design includes a robust control system, fault diagnostic system, and safety features. The pulsed power design includes 6 PFN modules, each including a dual series injection trigger transformer, that drive a total of 12 flash lamp loads. The lamps are individually triggered via a 20kV pulse produced by a 1kV, MCT switched capacitive discharge unit on the primary side of the trigger transformer. The remote control interface includes an embedded controller that captures flash lamp current wave forms and fault status for each shot. The embedded controller provides the flexibility of remotely adjusting both the main drive voltage from 1.6 to 2.5 kV and the trigger voltage from 0 to 20 kV.

James, G; Merritt, B; Dreifuerst, G; Strickland, S

2007-08-07T23:59:59.000Z

135

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents (OSTI)

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp.

Simpson, James E. (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

136

RF driven sulfur lamp having driving electrodes which face each other  

DOE Patents (OSTI)

A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance. 17 figs.

Gabor, G.; Orr, T.R.; Greene, C.M.; Crawford, D.G.; Berman, S.M.

1999-06-22T23:59:59.000Z

137

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents (OSTI)

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp. 18 figs.

Simpson, J.E.

1999-06-08T23:59:59.000Z

138

Issues, Models and Solutions for Triac Modulated Phase Dimming of LED Lamps  

E-Print Network (OSTI)

/a 30 lumens 0.1 Incandescent Bulb 15 W 225 lumens 15 Fluorescent Tube Lamp 10 W 500 lumens 50 White LED bulbs, and fluorescent lights, produce light that is radiated in all directions, LEDs produce a focused especially on the potential of white LED lights, which are an important and newly emerging lighting

Lehman, Brad

139

A Local AFOS MOS Program (LAMP) and its Application to Wind Prediction  

Science Conference Proceedings (OSTI)

The Techniques Development Laboratory has a project called the local AFOS MOS Program (LAMP). Its purpose is the development of a system which can produce at any hour of the day in a Weather Service Forecast Office (WSFO) environment Model Output ...

Harry R. Glahn; David A. Unger

1986-07-01T23:59:59.000Z

140

The Fuzzy Design of the Intelligent System for the Energy-Saving Lamps  

Science Conference Proceedings (OSTI)

In the paper, a intelligent system was proposed. It consists of variable converter and intelligent controller. Variable reactor which concludes variable reactance converter and power converter has wide applications in the soft starting, speed controlling ... Keywords: fuzzy control, variable reactor, intelligent control, power converter, Energy-Saving Lamps

Youxin Yuan; Kaihua Cui; Yiping Xiao; Tieliang Xu

2008-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

High frequency electronic ballast for HID lamps. Technical progress report, October 1, 1993--December 31, 1994  

SciTech Connect

Electronic Ballast Systems Corp. has been working on the development of highly efficient (94%) electronic ballast for HID lamps (35W,...,400W) providing energy savings of up to thirty five percent (35%) as compared to the only available alternative, the standard core and coil HID ballasts currently on the market.

1995-03-01T23:59:59.000Z

142

Electronic screw-in ballast and improved circline lamp phase I. Final report  

SciTech Connect

A solid state ballast has been designed for the efficient operation of a 10 in circline fluorescent lamp. The circuit can be manufactured using power hybrid technology. Eight discrete component versions of the ballasts have been delivered to LBL for testing. The results show the solid state fluorescent ballast system is more efficient than the core-coil ballasted systems on the market.

Kohler, T.P.

1980-09-01T23:59:59.000Z

143

A Comparative Verification of Localized Aviation Model Output Statistics Program (LAMP) and Numerical Weather Prediction (NWP) Model Forecasts of Ceiling Height and Visibility  

Science Conference Proceedings (OSTI)

In an effort to support aviation forecasting, the National Weather Service’s Meteorological Development Laboratory (MDL) has recently redeveloped the Localized Aviation Model Output Statistics (MOS) Program (LAMP) system. LAMP is designed to run ...

David E. Rudack; Judy E. Ghirardelli

2010-08-01T23:59:59.000Z

144

Stress Testing of the Philips 60W Replacement Lamp L Prize Entry  

SciTech Connect

The Pacific Northwest National Laboratory, operated by Battelle for the U.S. Department of Energy, worked with Intertek to develop a procedure for stress testing medium screw-base light sources. This procedure, composed of alternating stress cycles and performance evaluation, was used to qualitatively compare and contrast the durability and reliability of the Philips 60W replacement lamp L Prize entry with market-proven compact fluorescent lamps (CFLs) with comparable light output and functionality. The stress cycles applied simultaneous combinations of electrical, thermal, vibration, and humidity stresses of increasing magnitude. Performance evaluations measured relative illuminance, x chromaticity and y chromaticity shifts after each stress cycle. The Philips L Prize entry lamps appear to be appreciably more durable than the incumbent energy-efficient technology, as represented by the evaluated CFLs, and with respect to the applied stresses. Through the course of testing, all 15 CFL samples permanently ceased to function as a result of the applied stresses, while only 1 Philips L Prize entry lamp exhibited a failure, the nature of which was minor, non-destructive, and a consequence of a known (and resolved) subcontractor issue. Given that current CFL technology appears to be moderately mature and no Philips L Prize entry failures could be produced within the stress envelope causing 100 percent failure of the benchmark CFLs, it seems that, in this particular implementation, light-emitting diode (LED) technology would be much more durable in the field than current CFL technology. However, the Philips L Prize entry lamps used for testing were carefully designed and built for the competition, while the benchmark CFLs were mass produced for retail sale—a distinction that should be taken into consideration. Further reliability testing on final production samples would be necessary to judge the extent to which the results of this analysis apply to production versions of the Philips L Prize entry.

Poplawski, Michael E.; Ledbetter, Marc R.; Smith, Mark

2012-04-24T23:59:59.000Z

145

Treatability study for removal of leachable mercury in crushed fluorescent lamps  

SciTech Connect

Nonserviceable fluorescent lamps removed from radiological control areas at the Oak Ridge Department of Energy facilities have been crushed and are currently managed as mixed waste (hazardous and radiologically contaminated). We present proposed treatment flowsheets and supporting treatability study data for conditioning this solid waste residue so that it can qualify for disposal in a sanitary landfill. Mercury in spent fluorescent lamps occurs primarily as condensate on high-surface-area phosphor material. It can be solubilized with excess oxidants (e.g., hypochlorite solution) and stabilized by complexation with halide ions. Soluble mercury in dechlorinated saline solution is effectively removed by cementation with zero-valent iron in the form of steel wool. In packed column dynamic flow testing, soluble mercury was reduced to mercury metal and insoluble calomel, loading > 1.2 g of mercury per grain of steel wool before an appreciable breakthrough of soluble mercury in the effluent.

Bostick, W.D.; Beck, D.E.; Bowser, K.T. [and others

1996-02-01T23:59:59.000Z

146

Determination of mercury distribution inside spent compact fluorescent lamps by atomic absorption spectrometry  

Science Conference Proceedings (OSTI)

Highlights: Black-Right-Pointing-Pointer New treatments for CFL are required considering the aim of Directive 202/96/CE. Black-Right-Pointing-Pointer It is shown that most of the mercury introduced into a CFL is in the phosphor powder. Black-Right-Pointing-Pointer Experimental conditions for microwave-assisted sample digestion followed by AAS measurements are described. Black-Right-Pointing-Pointer By washing the glass it is possible to reduce the concentration below legal limits. - Abstract: In this study, spent compact fluorescent lamps were characterized to determine the distribution of mercury. The procedure used in this research allowed mercury to be extracted in the vapor phase, from the phosphor powder, and the glass matrix. Mercury concentration in the three phases was determined by the method known as cold vapor atomic absorption spectrometry. Median values obtained in the study showed that a compact fluorescent lamp contained 24.52 {+-} 0.4 ppb of mercury in the vapor phase, 204.16 {+-} 8.9 ppb of mercury in the phosphor powder, and 18.74 {+-} 0.5 ppb of mercury in the glass matrix. There are differences in mercury concentration between the lamps since the year of manufacture or the hours of operation affect both mercury content and its distribution. The 85.76% of the mercury introduced into a compact fluorescent lamp becomes a component of the phosphor powder, while more than 13.66% is diffused through the glass matrix. By washing and eliminating all phosphor powder attached to the glass surface it is possible to classified the glass as a non-hazardous waste.

Rey-Raap, Natalia [Departamento de Ingenieria Mecanica y Construccion, Universitat Jaume I de Castellon, Av. de Vicent Sos Baynat s/n, 12071 Castellon de la Plana, Espana (Spain); Gallardo, Antonio, E-mail: gallardo@emc.uji.es [Departamento de Ingenieria Mecanica y Construccion, Universitat Jaume I de Castellon, Av. de Vicent Sos Baynat s/n, 12071 Castellon de la Plana, Espana (Spain)

2012-05-15T23:59:59.000Z

147

Integrated-circuit control for two-lamp electronic ballast. Final report  

SciTech Connect

Circuitry is described for a solid-state, high-frequency fluorescent ballast designed to operate two F40 T-12 rapid-start lamps. The circuits are designed to be produced by hybrid integrated circuit (IC) technology. The signal components are produced on a single IC chip; the power transistors are attached to an alumina substrate. The initial IC version reduces the component count by about 50%. The cost of each IC in 500K lots is $0.70, replacing discrete parts costing $2.25. Additional savings of more than $1.00 per unit are realized by the decreased assembly time and improved reliability of the ICs. The system performance (two-lamp F40) was compared to the discrete version of the ballast and to an efficient core-coil ballast and found to be 6% less and 20% more efficient, respectively. The decrease in efficiency relative to the discrete version of the ballast is due to retaining some power to the filaments during operation in order to maintain normal lamp life.

Kohler, T.P.

1982-11-01T23:59:59.000Z

148

Experimental and theoretical investigations on the warm-up of a high-pressure mercury discharge lamp  

SciTech Connect

Modern high-pressure discharge lamps are forced to provide instant light and hot relight capabilities - if possible at lower power units. A detailed understanding of the warm-up of high-pressure discharge lamps is therefore required. Complex fluid model codes were developed for the past years including more and more processes like two-dimensional treatment of convection trying to provide a more comprehensive and consistent description of high-pressure discharge lamps. However, there is a lack of experimental data to examine the performance of these models. This work provides a very complete set of geometrical, electrical, spectroscopic, and thermographic data according to the warm-up of a high-pressure mercury discharge lamp that is compared to the results of a state of the art fluid code. Quantitative agreement is achieved for single parameters like wall temperatures. But the paper also reveals the need for further investigations and improvements of the code.

Zalach, J.; Franke, St.; Schoepp, H. [Leibniz Institute for Plasma Science and Technology, Felix-Hausdorff-Str. 2, D-17489 Greifswald (Germany); Araoud, Z.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, rte de Kairouan, 5019 Monastir (Tunisia); Zissis, G. [Laboratoire Plasma et Conversion d'Energie, 118 rte Narbonne, Bat3R2, 31062 Toulouse (France)

2011-03-15T23:59:59.000Z

149

A New Rb Lamp Exciter Circuit for Rb atomic clocks and Studies on Transition from Ring to Red mode  

E-Print Network (OSTI)

In this paper we describe the development of novel RF exciter circuit for electrode less Rb lamp. The lamp exciter circuit is a RF oscillator with a a new configuration operating at 60 to 65 MHz frequency with 3 to 4 watt power. The Rb lamp is used in exciting the ground state hyperfine transitions in Rb atom in a glass cell placed inside a tuned microwave cavity, As the frequency of these hyperfine transitions is very stable it is used in the development of Rb atomic clock by phase locking the oven controlled crystal oscillator (OCXO) to this atomic transition frequency. The details of the Rb lamp exciter are presented in the paper.The Lamp is ideally operated in ring mode as in this mode the linewidth is narrow and there is no self reversal. However, high temperature and RF excitation power may drive the Rb lamp to red mode which gives rise to line broadening and self reversal. It is the experience that mode change from ring to red deteriorates the atomic signal strength and S/N. In this paper the reasons of mode change are also discussed.

Savita Singh; Bikash Ghosal; G M Saxena

2010-11-10T23:59:59.000Z

150

Super-radiance in the sodium resonance lines from sodium iodide arc lamps  

Science Conference Proceedings (OSTI)

Super-radiance observed within the centers of the sodium resonance D lines emitted by arc lamps containing sodium iodide as additive in a high-pressure mercury plasma environment was studied by high-resolution emission spectroscopy. The spectral radiance of these self-reversed lines including super-radiance was simulated by considering a local enhancement of the source function due to the presence of an additional source of radiation near the arc wall. Causes of this hitherto unrecognized source of radiation are given.

Karabourniotis, D. [Department of Physics, Institute of Plasma Physics, University of Crete, 71003 Heraklion (Greece); Drakakis, E. [Department of Electrical Engineering, Technological Educational Institute, Heraklion (Greece)

2010-08-09T23:59:59.000Z

151

A high-efficiency indirect lighting system utilizing the solar 1000 sulfur lamp  

SciTech Connect

High-lumen light sources represent unique challenges and opportunities for the design of practical and efficient interior lighting systems. High-output sources require a means of large-scale distribution and avoidance of high-luminance glare while providing efficient delivery. An indirect lighting system has been developed for use with a 1,000 Watt sulfur lamp that efficiently utilizes the high-output source to provide quality interior lighting. This paper briefly describes the design and initial testing of this new system.

Siminovitch, M.; Gould, C.; Page, E.

1997-06-01T23:59:59.000Z

152

Experimental methodology for determining the system performance of fluorescent lamp, ballast, fixture combinations operating under realistic application conditions  

SciTech Connect

To meet the need for accurate performance data, an experimental method for determining the performance of lamp, ballast, and luminaire combinations operating under a broad range of realistic conditions was developed. The methodology employs a two-part experimental procedure. The first part uses a temperature-controlled luminous flux integrator to characterize the thermal performance of each lamp/ballast combination. This performance characterization is expressed in terms of light output and efficacy as a function of variations in minimum lamp wall temperature (MLWT) and is generated for the range of temperatures typically encountered in interior lighting applications. The second procedure uses a luminaire/plenum simulator to determine the specific MLWT that exists in a particular luminaire application as a function of luminaire type, mounting configuration, plenum integration, and room air temperature. The MLWTs thus measured may be used in conjunction with the lamp/ballast performance data to determine application-specific values of light output and efficacy for a given lamp/ballast/luminaire system.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.

1984-11-01T23:59:59.000Z

153

Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg.sup.196 enrichment  

DOE Patents (OSTI)

The present invention is directed to a method of eliminating the cold spot zones presently used on Hg.sup.196 isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

Grossman, Mark W. (Belmont, MA)

1993-01-01T23:59:59.000Z

154

Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg[sup 196] enrichment  

DOE Patents (OSTI)

The present invention is directed to a method of eliminating the cold spot zones presently used on Hg[sup 196] isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

Grossman, M.W.

1993-02-16T23:59:59.000Z

155

Energy Savings and NOx Emissions Reduction Potential from the 2012 Federal Legislation to Phase Out Incandescent Lamps in Texas  

E-Print Network (OSTI)

This report provides detailed information about the potential savings from the 2012 Federal Legislation to phase out incandescent lamps and the NOx emissions reduction from the replacement of incandescent bulbs with Compact Fluorescent Lamps (CFL). In Texas, this analysis includes the savings estimates from both the annual and Ozone Season Day (OSD) NOx reductions. The NOx emissions reduction in this analysis are calculated using estimated emissions factors for 2007 from the US Environmental Protection Agency (US EPA) eGRID database, which had been specially prepared for this purpose.

Liu, Zi; Baltazar, Juan Carlos; Haberl, Jeff; Soman, Rohit

2010-03-01T23:59:59.000Z

156

THERMAL ANNEALING OF ZNO FILMS USING HIGH-DENSITY PLASMA ARC LAMPS  

Science Conference Proceedings (OSTI)

Nanostructured materials are rarely synthesized with appropriate phase and/or morphology. In this study, critical additional of as-synthesized nanostructured materials, such as annealing and/or activation of dopants, are addressed using infrared plasma arc lamps (PAL) over areas as large as 1,000 cm2. The broad spectral range of the PAL and the spectral variation of light absorption in nanostructured materials make the selection of processing parameters extremely difficult, posing a major technological barrier. In this study, the measurement of the surface temperature using various techniques for ZnO films on crystalline silicon wafers is discussed. An energy transport model for the simulation of rapid thermal processing using PAL is presented. The experimental and computational results show that the surface temperature cannot be measured directly and that computer simulation results are an effective tool for obtaining accurate data on processing temperatures.

Sabau, Adrian S [ORNL; Dinwiddie, Ralph Barton [ORNL; Xu, Jun [ORNL; Angelini, Joseph Attilio [ORNL; Harper, David C [ORNL

2011-01-01T23:59:59.000Z

157

NIST energy related inventions: Electronic starter device for fluorescent lamps. Interim report, August--October, 1997  

SciTech Connect

From the Scope of Work document which accompanied the original proposal, three silicon devices were anticipated for development, simulation, and quality assurance fabrication. The status of these are in the same format as the Scope of Work...Attachment-A-: Task 1--design and simulation; Task 2--prototype tooling; Task 3--test engineering; Task 4--product tooling; Task 5--package tooling/manufacturing design and assembly. It is felt the program will meet it`s stated goals of producing a low cost, high performance fluorescent lamp starter which will lower the acquisition and operating cost of fluorescent technology...thus saving significant amounts of energy. The likelihood of success is even greater, now that the TN22 component has been qualified. The challenges of creating a custom ASIC, while still significant, are within the skill and expertise level or the assigned engineers.

Johnson, S.A.

1997-12-01T23:59:59.000Z

158

Mercury reduction studies to facilitate the thermal decontamination of phosphor powder residues from spent fluorescent lamps  

SciTech Connect

This work investigates the thermal release of mercury from phosphor powder of spent fluorescent lamps. The treatment conditions and the ability of various reducing agents (primarily sodium borohydride) to lower the overall heating temperature required to improve the release of Hg have been evaluated. Hg species in samples were monitored in a thermal desorption atomic absorption spectrometer system, and total mercury was analyzed in a cold vapor atomic absorption spectrometer. Sodium borohydride was the best reducing agent among the ones studied. However, citric acid presented a high capacity to weaken mercury bonds with the matrix. When the sample was crushed with sodium borohydride for 40 min in a mass ratio of 10:1 (sample:reducing agent) and submitted to thermal treatment at 300 deg. C for 2 h, the concentration of mercury in a phosphor powder sample with 103 mg kg{sup -1} of mercury reached 6.6 mg kg{sup -1}.

Alves Durao, Walter [Chemistry Department, Federal University of Minas Gerais (UFMG), Cidade Universitaria 30.123-970 Belo Horizonte, MG (Brazil); Andreva de Castro, Camila [Chemistry Engineering Department, Federal University of Minas Gerais (UFMG) (Brazil); Carvalhinho Windmoeller, Claudia [Chemistry Department, Federal University of Minas Gerais (UFMG), Cidade Universitaria 30.123-970 Belo Horizonte, MG (Brazil)], E-mail: claucw@netuno.lcc.ufmg.br

2008-11-15T23:59:59.000Z

159

Archaeological data visualization in VR: analysis of lamp finds at the great temple of petra, a case study  

Science Conference Proceedings (OSTI)

We present the results of an evaluation of the ARCHAVE system, an immersive virtual reality environment for archaeological research. ARCHAVE is implemented in a Cave. The evaluation studied researchers analyzing lamp and coin finds throughout the excavation ... Keywords: archaeological data analysis, immersive virtual reality interfaces, scientific visualization

Daniel Acevedo; Eileen Vote; David H. Laidlaw; Martha S. Joukowsky

2001-10-01T23:59:59.000Z

160

Application of a three-dimensional model for a study of the energy transfer of a high-pressure mercury horizontal lamp  

Science Conference Proceedings (OSTI)

This paper is devoted to study the dynamics of a discharge lamp with high intensity in a horizontal position. As an example of application, we chose the high-pressure mercury lamp. For this, we realized a three-dimensional model, a stable and powered DC. After the validation of this model, we used it to reproduce the influence of some parameters that have appeared on major transport phenomena of mass and energy in studying the lamp operating in a horizontal position. Indeed, the mass of mercury and the electric current are modified and the effect of convective transport is studied.

Ben Hamida, M. B.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, 5019 route de Kairouan Monastir (Tunisia)

2012-06-15T23:59:59.000Z

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet. 7 figs.

Ury, M.; Sowers, F.; Harper, C.; Love, W.

1998-11-24T23:59:59.000Z

162

Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet.

Ury, Michael (Bethesda, MD); Sowers, Frank (Frederick, MD); Harper, Curt (Wheaton, MD); Love, Wayne (Olney, MD)

1998-01-01T23:59:59.000Z

163

Mechanical design of PlayLamp : a minimally intrusive device for recording the behavior of children at-risk of developmental disorders  

E-Print Network (OSTI)

This thesis paper documents the design process, decisions, and outcomes of the design of the physical form factor of PlayLamp, a device for video and audio recording the development of children at-risk of having developmental ...

Steger, Stephen Andrew

2008-01-01T23:59:59.000Z

164

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

Science Conference Proceedings (OSTI)

Creation of light for work, socializing, and general illumination is a fundamental application of technology around the world. For those who lack access to electricity, an emerging and diverse range of LED based lighting products hold promise for replacing and/or augmenting their current fuel-based lighting sources that are costly and dirty. Along with analysis of environmental factors, economic models for total cost-ofownership of LED lighting products are an important tool for studying the impacts of these products as they emerge in markets of developing countries. One important metric in those models is the minimum illuminance demanded by end-users for a given task before recharging the lamp or replacing batteries. It impacts the lighting service cost per unit time if charging is done with purchased electricity, batteries, or charging services. The concept is illustrated in figure 1: LED lighting products are generally brightest immediately after the battery is charged or replaced and the illuminance degrades as the battery is discharged. When a minimum threshold level of illuminance is reached, the operational time for the battery charge cycle is over. The cost to recharge depends on the method utilized; these include charging at a shop at a fixed price per charge, charging on personal grid connections, using solar chargers, and purchasing dry cell batteries. This Research Note reports on the observed"charge-triggering" illuminance level threshold for night market vendors who use LED lighting products to provide general and task oriented illumination. All the study participants charged with AC power, either at a fixed-price charge shop or with electricity at their home.

Johnstone, Peter; Jacobson, Arne; Mills, Evan; Radecsky, Kristen

2009-03-21T23:59:59.000Z

165

GLASS AND GLASS-DERIVATIVE SEALS FOR USE IN ENERGY-EFFICIENT FUEL CELLS AND LAMPS  

DOE Green Energy (OSTI)

As the project approaches the end of the first year, the materials screening components of the work are ahead of schedule, while all other tasks are on schedule. For solid oxide fuel cells (SOFC), a series of 16 sealing glasses have been prepared and characterized. Traditional melting was used to prepare all of the glasses, and the sol-gel approach has been used to prepare some of the glasses as well as other compositions that might be viable because of the low processing temperatures afforded by the sol-gel method. The glass characterization included measurements of the viscosity and thermal expansion of the glasses, as well as the thermal expansion of the partly crystalline glass ceramics. In addition, the wetting and sintering behavior of all glasses has been measured, as well as the crystallization behavior. The time and temperature at which crystalline phases form from the glasses has been determined for all of the glasses. Each glass ceramic contains at least two crystalline phases, and most of the crystalline phases have been positively identified. Room temperature leak testing has been completed for all sealants, and experiments are in progress to determine the DC electrochemical degradation and degradation in wet hydrogen. The second component of the work, focused on seals for higher-temperature discharge lighting, has focused on determining the phase relations in the yttria--alumina--silica system at various silica levels. Again, traditional melting and sol-gel synthesis have been employed, and the sol-gel method was successful for preparing new phases that were discovered during the work. High temperature diffraction and annealing studies have clarified the phase relations for the samples studies, although additional work remains. Four new phases have been identified and synthesized in pure form, from which full structure solutions were obtained as well as the anisotropic thermal expansion for each phase. Functional testing of lamps are on on-going and will be analyzed during year 2 of the contract.

Scott Misture; Arun Varshneya; Matthew Hall; Sylvia DeCarr; Steve Bancheri

2004-08-15T23:59:59.000Z

166

Glass and glass-derivative seals for use in energy-efficient fuel cells and lamps  

DOE Green Energy (OSTI)

For solid oxide fuel cells (SOFC), a series of 18 sealing glasses have been prepared and characterized. From the whole design space, several glasses were ''downselected'' and studied in detail to describe their behaviors in simulated fuel cell environments. One of the glasses was found to outperform all others, including the well-known G18 sealant developed at Pacific Northwest National Laboratory. The new glass composition showed lower bulk electrical conductivity, excellent sealing and wetting behavior when sealing under applied load, and qualitatively superior performance when exposed to wet hydrogen for 800 hours. Traditional melting was used to prepare all of the glasses that were studied in detail. The sol-gel approach was used to synthesize several compositions, but it was found that the glasses crystallized very rapidly during heating, precluding sealing. The glass characterization included measurements of the viscosity and thermal expansion of the glasses, as well as the thermal expansion of the partly crystalline glass ceramics. In addition, the wetting and sintering behavior of all glasses has been measured, as well as the crystallization behavior. The time and temperature at which crystalline phases form from the glasses has been determined for all of the glasses. Each glass ceramic contains at least two crystalline phases, and most of the crystalline phases have been positively identified. The body of fundamental data provides a platform for future developments for high temperature sealants, and the newly-developed glass compositions appear promising for large-scale testing. The second component of the work, focused on seals for higher-temperature discharge lighting, has focused on determining the phase relations in the yttria-alumina-silica system at various silica levels. Functional testing of one of the candidate sealants demonstrated that it performs well in current HID lighting applications. Further testing is required to evaluate its performance in next-generation lamps that operate at higher temperatures, but the baseline phase equilibria and crystallization behavior has been established for additional development. Again, traditional melting and sol-gel synthesis have been employed, and the sol-gel method was successful for preparing new phases that were discovered during the work. Four new phases have been identified and synthesized in pure form, from which full structure solutions were obtained as well as the anisotropic thermal expansion for each phase.

Scott Misture; Arun Varshineya; Matthew Hall; Sylvia DeCarr; Steve Bancheri

2005-07-28T23:59:59.000Z

167

Process for environmentally safe disposal of used fluorescent lamp potted ballast assemblies with component part reclamation and/or recycling  

SciTech Connect

A process is described for the environmentally safe and economical disposal of used fluorescent lamp potted ballast housing assemblies comprising removing from the housing the potted assembly with its embedded electrical component assemblies including a component capacitor containing environmentally hazardous material PCB's; after or before such removing, immersing the potted assembly in a cryogenic bath and freezing the same to reader the potting sufficiently brittle to fragment into small pieces upon being impacted; impacting the potting thoroughly to crush and fragment the same into small pieces and to cleanly remove substantially all traces of the potting from all the electrical components and parts embedded therein and without imparting damage to the components and parts; disconnecting the component containing the environmentally hazardous material; and incinerating only the component containing the environmentally hazardous material, leaving all other components and parts including the housing and potting fragments for salvage, re-use and/or recycling.

Nardella, A.; Norian, B.

1993-07-27T23:59:59.000Z

168

Exploration of illumination concepts for underground coal mines. Appendix E. Electronic ballast for the Lucalox high pressure sodium lamp. Final report  

SciTech Connect

The report documents the results of an investigation to develop solid-state ballasts for Lucalox high-pressure sodium lamps. The ballasts were to be used in the modified and new portable and machine-mounted lighting systems designed by the Crouse-Hinds Co., per tasks I through IV of Contract No. H022065.

1976-07-20T23:59:59.000Z

169

Demonstration of LED Retrofit Lamps at an Exhibit of 19th Century Photography at the Getty Museum  

SciTech Connect

This document is a report of observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy (DOE) GATEWAY Demonstration Program. The program supports demonstrations of high-performance solid-state lighting (SSL) products in order to develop empirical data and experience with in-the-field applications of this advanced lighting technology. The DOE GATEWAY Demonstration Program focuses on providing a source of independent, third-party data for use in decision-making by lighting users and professionals; this data should be considered in combination with other information relevant to the particular site and application under examination. Each GATEWAY Demonstration compares SSL products against the incumbent technologies used in that location. Depending on available information and circumstances, the SSL product may also be compared to alternate lighting technologies. Though products demonstrated in the GATEWAY program may have been prescreened for performance, DOE does not endorse any commercial product or in any way guarantee that users will achieve the same results through use of these products. This report reviews the installation and use of LED PAR38 lamps to light a collection of toned albument photographic prints at the J. Paul Getty Museum in Malibu, California. Research results provided by the Getty Conservation Institute are incorporated and discussed.

Miller, Naomi J.; Druzik, Jim

2012-03-02T23:59:59.000Z

170

DOE CALiPER Program, Report 20.1 Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps  

Science Conference Proceedings (OSTI)

This report focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality. Using a questionnaire that included rank ordering, opinions on 27 of the Report 20 PAR38 lamps were gathered during a demonstration event for members of the local Illuminating Engineering Society (IES) chapter. This was not a rigorous scientific experiment, and the data should not be extrapolated beyond the scope of the demonstration. The results suggest that many of the LED products compared favorably to halogen PAR38 benchmarks in all attributes considered. LED lamps using a single-emitter design were generally preferred for their beam quality and shadow quality, and the IES members ranking of color quality did not always match the rank according to the color rendering index (CRI).

Royer, Michael P.; Poplawski, Michael E.; Miller, Naomi J.

2013-10-01T23:59:59.000Z

171

Atomic gas temperature in a nonequilibrium high-intensity discharge lamp determined from the red wing of the resonance mercury line 254 nm  

Science Conference Proceedings (OSTI)

For developing low-wattage high intensity discharge (HID) lamps, a better understanding of the relatively unexplored nonequilibrium phenomena is essential. This needs interpretation of diagnostic results by methods free from equilibrium assumptions. In this paper, the atomic temperature is determined from the simulation of a quasistatic broadened resonance line by distinguishing between atomic temperature and excitation temperature in the equation of radiative transfer. The proposed method is applied to the red wing of the resonance mercury line 254 nm emitted from a HID lamp working on ac. The experimental results show severe deviation from local thermodynamic equilibrium. More than one thousand degrees difference was obtained between atomic and electron temperatures at the maximum current phase.

Drakakis, E. [Technological Educational Institute, Department of Electrical Engineering, 71004 Heraklion (Greece); Karabourniotis, D. [Institute of Plasma Physics, Department of Physics, University of Crete, 71003 Heraklion (Greece)

2012-09-01T23:59:59.000Z

172

DOE/EA-1664: Environmental Assessment for 10 CFR 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps (June 2009)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4 4 Environmental Assessment for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps June 2009 16-i CHAPTER 16. ENVIRONMENTAL ASSESSMENT TABLE OF CONTENTS 16.1 INTRODUCTION ......................................................................................................... 16-1 16.2 AIR EMISSIONS ANALYSIS...................................................................................... 16-1 16.2.1 Air Emissions Descriptions............................................................................................ 16-1 16.2.2 Air Quality Regulation................................................................................................... 16-3 16.2.3 Global Climate Change..................................................................................................

173

Assessment of Electrical, Efficiency, and Photometric Performance of Advanced Lighting Sources: Dimmable Advanced Lighting Technolog ies -- Electronic (Hot and Cold Cathode) Compact Fluorescent Lamps and Ballasts  

Science Conference Proceedings (OSTI)

This EPRI Technical Update (EPRI report 1018477) is one of four in a series that addresses basic dimming performance of advanced lighting sourceselectronic (hot and cold cathode) compact fluorescent lamps and ballasts Chapter 1 discusses basic lighting control, the importance of considering power quality in lighting control, lighting control methods and parameters, and the advantages and future of lighting control. Chapter 2 addresses in more depth dimming methods used in advanced lighting sources and co...

2008-12-19T23:59:59.000Z

174

L&E: Participate in a field test for high-efficiency troffer lighting. |  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting & Electrical » Participate Lighting & Electrical » Participate in a field test for high efficiency troffer lighting Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Participate in a field test for high-efficiency troffer lighting 50% of all commercial fluorescent lighting fixtures are recessed troffers in 1'x4', 2'x2' and 2'x4' configurations, in operation for more than 10 hours a day on average and collectively consuming more than 87 TWh of electricity annually. The Lighting & Electrical team supported the market introduction of high-efficiency troffers by developing a specification that allows for

175

Phosphors for LED lamps  

DOE Patents (OSTI)

A phosphor, a phosphor blend including the phosphor, a phosphor prepared by a process, and a lighting apparatus including the phosphor blend are disclosed. The phosphor has the formula (Ca.sub.1-p-qCe.sub.pK.sub.q).sub.xSc.sub.y(Si.sub.1-rGa.sub.r).sub.zO.su- b.12+.delta. or derived from a process followed using disclosed amounts of reactants. In the formula, (0

Murphy, James Edward; Manepalli, Satya Kishore; Kumar, Prasanth Nammalwar

2013-08-13T23:59:59.000Z

176

Decontamination Strategy for Large Area and/or Equipment Contaminated with Chemical and Biological Agents using a High Energy Arc Lamp (HEAL)  

Science Conference Proceedings (OSTI)

A strategy for the decontamination of large areas and or equipment contaminated with Biological Warfare Agents (BWAs) and Chemical Warfare Agents (CWAs) was demonstrated using a High Energy Arc Lamp (HEAL) photolysis system. This strategy offers an alternative that is potentially quicker, less hazardous, generates far less waste, and is easier to deploy than those currently fielded by the Department of Defense (DoD). For example, for large frame aircraft the United States Air Force still relies on the combination of weathering (stand alone in environment), air washing (fly aircraft) and finally washing the aircraft with Hot Soapy Water (HSW) in an attempt to remove any remaining contamination. This method is laborious, time consuming (upwards of 12+ hours not including decontamination site preparation), and requires large amounts of water (e.g., 1,600+ gallons for a single large frame aircraft), and generates large amounts of hazardous waste requiring disposal. The efficacy of the HEAL system was demonstrated using diisopropyl methyl phosphonate (DIMP) a G series CWA simulant, and Bacillus globigii (BG) a simulant of Bacillus anthracis. Experiments were designed to simulate the energy flux of a field deployable lamp system that could stand-off 17 meters from a 12m2 target area and uniformly expose a surface at 1360 W/m2. The HEAL system in the absence of a catalyst reduced the amount of B. globigii by five orders of magnitude at a starting concentration of 1.63 x 107 spores. In the case of CWA simulants, the HEAL system in the presence of the catalyst TiO2 effectively degraded DIMP sprayed onto a 100mm diameter Petri dish in 5 minutes.

Schoske, Richard [ORNL; Kennedy, Patrick [ORNL; Duty, Chad E [ORNL; Smith, Rob R [ORNL; Huxford, Theodore J [ORNL; Bonavita, Angelo M [ORNL; Engleman, Greg [ORNL; Vass, Arpad Alexander [ORNL; Griest, Wayne H [ORNL; Ilgner, Ralph H [ORNL; Brown, Gilbert M [ORNL

2009-04-01T23:59:59.000Z

177

Lamps in the Leaping Over  

E-Print Network (OSTI)

‘dusgser gyi nya mo ‘khor lo bskor ba’i rgyud chen po: /rang byung lhun grub ‘bras bu n/ /gdod naslhun grub rang ‘char bas/ /’byung ba lnga la rag ma pas/ /sku gsung thugs la rten mi ‘cha’/ /gsalbyed rig pa’i sgron ma yi s/ /gter khyim phung po gsal byed... / /longs sku dang nisprul pa’i sku/ /chu shel sgron ma’i dpes mtshon kyang/da lta rang la ‘byung ma srid/ /khyung sgoma chag ‘phur mi nus/.14 See TTT 54, p. 504, eigthth chapter of the Byang chub kyi sems rin chen ‘khor lo: /sems nyid rigpa’i sgron ma yis...

Scheidegger, Daniel

2005-01-01T23:59:59.000Z

178

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

in distribution transformers for power factor correction.of the power factors at the distribution transformers, or at

Gadgil, A.J.

2008-01-01T23:59:59.000Z

179

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network (OSTI)

certain whether the electrical power is off or on, he may beof light. The electrical input (power, voltage and current)

Verderber, Rudy

2013-01-01T23:59:59.000Z

180

L Prize Competition Winner: 60W Incandescent Replacement Lamp  

NLE Websites -- All DOE Office Websites (Extended Search)

Prize Partners 14 15 Field Assessments: Retail Platte River Power Authority DTE Energy SMUD 16 Additional Opportunities: GATEWAY Demonstrations of LED Outdoor Lighting Reports...

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

A Study on Electrodes for Capacitive Discharging UV Lamp  

Science Conference Proceedings (OSTI)

J10: Mechanical Properties and Welding Conditions of Monopile and Transition for Offshore Wind Plant · J12: Microstructure and Mechanical Properties of ...

182

Characterization of Fluorescent Lamp Glass Waste Powders for ...  

Science Conference Proceedings (OSTI)

The glass waste presents favorable characteristics for incorporation into clayey ceramic ... Codin, Located in Campos (RJ), to Produce Soil-Cement Blocks.

183

Recycling of Fluorescent Lamp Glass into Clayey Ceramic  

Science Conference Proceedings (OSTI)

Designing a Collaborative System for Socio-Environmental Management of ... Oils Post-Consumption Residential and Commercial Clay with Two Brazilian.

184

Zero energy-storage ballast for compact fluorescent lamps  

DOE Patents (OSTI)

A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast. 4 figs.

Schultz, W.N.; Thomas, R.J.

1999-08-31T23:59:59.000Z

185

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network (OSTI)

placed into light bulb sockets (Edison sockets) and the lampbe inserted into the same Edison type socket that is usedto injury. In addition, Edison sockets that are hori~

Verderber, Rudy

2013-01-01T23:59:59.000Z

186

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

representative electricity prices, because the residentialand 11. The range of electricity prices shown in the Figs.between mar- ginal electricity prices and residential tariff

Gadgil, A.J.

2008-01-01T23:59:59.000Z

187

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

and commercial electricity tariffs in each country. Noticemar- ginal electricity prices and residential tariff~. Anelectricity prices, because the residential tariff structure

Gadgil, A.J.

2008-01-01T23:59:59.000Z

188

Candelabra and Intermediate Base Lamps Enforcement Policy Statement  

Energy.gov (U.S. Department of Energy (DOE))

The Department issued guidance today advising manufacturers, importers and private labelers that DOE will not enforce the energy conservation standards and compliance certification requirements for...

189

The Therapeutic Lamp: Treating Small-Animal Phobias  

Science Conference Proceedings (OSTI)

We all have an irrational fear or two. Some of us get scared by an unexpected visit from a spider in our house; others get nervous when they look down from a high building. Fear is an evolutionary and adaptive function that can promote self-preservation ... Keywords: Animals,Medical treatment,Games,Visualization,Augmented reality,computer graphics,augmented reality,cockroach phobia,spider phobia,arachnophobia,anxiety,anxiety disorders,phobias,phobia therapy,psychological treatment

Maja Wrzesien, Mariano Alcaniz, Cristina Botella, Jean-Marie Burkhardt, Juana Breton-Lopez, Mario Ortega, Daniel Beneito Brotons

2013-01-01T23:59:59.000Z

190

L Prize Competition Winner 60W Incandesent Replacement Lamp Update  

NLE Websites -- All DOE Office Websites (Extended Search)

soon. --Senator Jeff Bingaman, D-NM What's the Buzz? - Would You Buy A 60 Light Bulb That Lasts 20 Years? -game-changing technology L Prize Helps Federal Purchasers:...

191

iLamps: geometrically aware and self-configuring projectors  

Science Conference Proceedings (OSTI)

Projectors are currently undergoing a transformation as they evolve from static output devices to portable, environment-aware, communicating systems. An enhanced projector can determine and respond to the geometry of the display surface, and can be used ... Keywords: ad-hoc clusters, augmented reality, calibration, projector, quadric transfer, seamless display

Ramesh Raskar; Jeroen van Baar; Paul Beardsley; Thomas Willwacher; Srinivas Rao; Clifton Forlines

2005-07-01T23:59:59.000Z

192

iLamps: geometrically aware and self-configuring projectors  

Science Conference Proceedings (OSTI)

Projectors are currently undergoing a transformation as they evolve from static output devices to portable, environment-aware, communicating systems. An enhanced projector can determine and respond to the geometry of the display surface, and can be used ... Keywords: ad-hoc clusters, augmented reality, calibration, projector, quadric transfer, seamless display

Ramesh Raskar; Jeroen van Baar; Paul Beardsley; Thomas Willwacher; Srinivas Rao; Clifton Forlines

2006-07-01T23:59:59.000Z

193

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

1.7% of in- stalled hydroelectric capacity. Op. cit. ref [in Ig86) based on hydroelectric generation, and most of thethe still abundant hydroelectric potential of the country.

Gadgil, A.J.

2008-01-01T23:59:59.000Z

194

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

the functions of generation and distribution are separated,undertake generation, transmission, and distribution (e.g.paid by the distribution utility to the generation utility.

Gadgil, A.J.

2008-01-01T23:59:59.000Z

195

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

demonstration (like street lights) and commercialization andthe dominant light source for street and roadway lighting,has been a popular light source for street lighting because

Scholand, Michael

2012-01-01T23:59:59.000Z

196

Spectroscopy on Metal-Halide Lamps under Varying Gravity Conditions  

E-Print Network (OSTI)

orange street lighting), which has a slightly lower discharge conversion efficiency, but the 589 nm line. They are mainly used for applications where a high light output is desired; examples are shop lighting, street. Haverlag Copromotor: dr.ir. W.W. Stoffels Copyright c 2008 by A.J. Flikweert This research was financially

Eindhoven, Technische Universiteit

197

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

presents the national energy consumption profile for HIDVolume I: National Lighting Inventory and Energy Consumption

Scholand, Michael

2012-01-01T23:59:59.000Z

198

Ancient Lamps, Earrings Yield Their Secrets Under Neutron Imaging...  

NLE Websites -- All DOE Office Websites (Extended Search)

(3-D) neutron images have been taken of rare archaeological artifacts. Bronze and brass artifacts excavated at the ancient city of Petra, in present day Jordan, were recently...

199

Flash Lamp Curing of Printed Nano-Particle Films  

Science Conference Proceedings (OSTI)

About this Abstract. Meeting, Materials Science & Technology 2009. Symposium, Controlled Processing of Nanoparticle-Based Materials and Nanostructured ...

200

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

1988. The private sector in Brazil owned (in 1986) 40% ofElectricity Conservation in Brazil: Potential and Pro-electricity consumption in Brazil's residential sector was

Gadgil, A.J.

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Phosphor blends for high-CRI fluorescent lamps  

DOE Patents (OSTI)

A phosphor blend comprises at least two phosphors each selected from one of the groups of phosphors that absorb UV electromagnetic radiation and emit in a region of visible light. The phosphor blend can be applied to a discharge gas radiation source to produce light sources having high color rendering index. A phosphor blend is advantageously includes the phosphor (Tb,Y,LuLa,Gd).sub.x(Al,Ga).sub.yO.sub.12:Ce.sup.3+, wherein x is in the range from about 2.8 to and including 3 and y is in the range from about 4 to and including 5.

Setlur, Anant Achyut (Niskayuna, NY); Srivastava, Alok Mani (Niskayuna, NY); Comanzo, Holly Ann (Niskayuna, NY); Manivannan, Venkatesan (Clifton Park, NY); Beers, William Winder (Chesterland, OH); Toth, Katalin (Pomaz, HU); Balazs, Laszlo D. (Budapest, HU)

2008-06-24T23:59:59.000Z

202

Stadiums and arenas use efficient, high wattage lamps - Today in ...  

U.S. Energy Information Administration (EIA)

Tools; Glossary › All Reports ... weather; gasoline; capacity; exports; nuclear; forecast; View All Tags ...

203

Apparatus to facilitate lengthening the life of incandescent lamps  

SciTech Connect

An energizing circuit is described for an incandescent bulb comprising a transformer having a primary winding connectable to an AC mains source and first and second secondary windings for producing first and second voltages. The first secondary winding is connected to an input of a first full-wave rectifier means and the second secondary winding is connected to an input of a second full-wave rectifier means, the full-wave rectifier means having outputs connected in parallel across the bulb. The first voltage is sufficient to fully illuminate the bulb and the second voltage is sufficient to maintain the bulb warm but with little or no light output, a first switch being connected between the first secondary winding and the first rectifier means whereby, when the first switch is open, the bulb is energized solely by the second voltage.

Spissinger, F.H.

1987-03-17T23:59:59.000Z

204

Series Resonant Inverter with Contactless Transformers for Multiple LED Lamps.  

E-Print Network (OSTI)

??A half-bridge series-resonant inverter adopted to realize the quasi current source and the constant current source with a number of contactless transformers in series for… (more)

Cheng, Shuen-Wen

2013-01-01T23:59:59.000Z

205

NOPM and Availability of Framework Document for HID Lamps  

NLE Websites -- All DOE Office Websites (Extended Search)

8:48 Feb 27, 2012 8:48 Feb 27, 2012 Jkt 226001 PO 00000 Frm 00008 Fmt 4702 Sfmt 4702 E:\FR\FM\28FEP1.SGM 28FEP1 mstockstill on DSK4VPTVN1PROD with PROPOSALS Federal Register / Vol. 77, No. 39 / Tuesday, February 28, 2012 / Proposed Rules 11785 collections for particular program, except where required by statute. III. Questions for Comment The list below includes the questions about these reform ideas that address issues which are of greatest interest to OMB at this stage of the process. Comments addressing any other concerns, and other types of feedback, are also welcome. In addition, as was explained at the beginning of this notice, the public comments received by OMB will be posted on OMB's Web site and at http:// www.regulations.gov. Accordingly, please do not include in your comments

206

Zero energy-storage ballast for compact fluorescent lamps  

DOE Patents (OSTI)

A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast.

Schultz, William Newell (Niskayuna, NY); Thomas, Robert James (Rexford, NY)

1999-01-01T23:59:59.000Z

207

Electronic Fluorescent Lamp Ballasts Used in 4-Foot Fixtures  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the EPRI Power Electronics Applications Center (PEAC) Power Quality Test Facility to characterize ballast energy performance, emissions, and immunity from a PQ perspective.

2003-12-31T23:59:59.000Z

208

GREEN BUILDING GUIDELINES UNIVERSITY OF MASSACHUSETTS AMHERST  

E-Print Network (OSTI)

Engineers (CIBSE) with an average lamp output 55% of the maximum [8]. Proprietary granular lighting control

Massachusetts at Amherst, University of

209

SCHOOl OF THE BUIlT ENVIRONmENT 35128 Undergraduate Prospectus `10  

E-Print Network (OSTI)

recommended by the Char- tered Institution of Building Services Engineers (CIBSE) with an average lamp output

Singer, Jeremy

210

J. Fluid Mech. (2001), vol. 426, pp. 355386. Printed in the United Kingdom c 2001 Cambridge University Press  

E-Print Network (OSTI)

Engineers (CIBSE) with an average lamp output 55% of the maximum [8]. Proprietary granular lighting control

Linden, Paul F.

211

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 3, Water heaters, pool heaters, direct heating equipment, and mobile home furnaces  

SciTech Connect

This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.

Not Available

1993-11-01T23:59:59.000Z

212

L&E: Refrigerated Display Case | The Better Buildings Alliance  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting & Electrical » Adopt the Lighting & Electrical » Adopt the refrigerated display case lighting performance specification and start saving on your case lighting costs Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt the refrigerated display case lighting performance specification and start saving on your case lighting costs The LED Refrigerated Display Case Lighting Specification delivers nearly 50% energy savings compared to typical display case lighting. If all retail refrigerated display cases switched today to LED systems, over 2.1 TWh of electricity could be saved annually. LED Refrigerated Display Case Lighting Specification

213

L&E - high efficiency lighting for parking structure | The Better Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

structure structure Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt high-efficiency lighting for your parking structure Parking structures and garages are typically lighted by older HID lighting technology without any energy-saving controls. The latest high-efficiency alternatives with energy-saving controls-including light-emitting diode (LED), induction, and fluorescent technology options-can save building owners over 40% on their parking lot lighting bills while delivering additional benefits such as better-lighted spaces. The Lighting & Electrical team developed a performance specification that

214

L&E: Adopt high-efficiency lighting for your parking lot | The Better  

NLE Websites -- All DOE Office Websites (Extended Search)

lot lot Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt high-efficiency lighting for your parking lot Most parking lots are illuminated by older high-intensity discharge (HID) lighting technology without any energy-saving controls. New light-emitting diode (LED) technology can cut parking lot lighting energy bills by 40%, or much more with controls, while delivering additional benefits including long life, reduced maintenance costs, and improved lighting uniformity. The Lighting & Electrical team developed a performance specification to help building owners take advantage of these improved lighting

215

Side-by-Side Testing of Commercial Office Lighting Systems: Two-lamp Fluorescent Fixtures  

E-Print Network (OSTI)

Lighting systems in commercial office buildings are primary determinants of building energy use. In warmer climates, lighting energy use has important implications for building cooling loads as well as those directly associated with illumination tasks. To research the comparative performance of conventional and advanced office lighting systems, Florida Solar Energy Center (FSEC) set up the Lighting Flexible Test Facility (LFTF) which allows side-by-side comparison of lighting options in two otherwise identical 2.7 m x 3.7 m (9' x 12') south facing offices. The ceiling of the LFTF contains 0.61 m x 1.2 m (2' x 4') recessed fluorescent fixtures designed to be easily changed. Differing lighting systems were comparatively tested against each other over weeklong periods. Data on power consumption (watts), power quality (power factor), work-plane interior lighting levels (lux), bulb-wall, fixture and plenum temperatures were recorded every 15 minutes on a multi-channel data logger. This data allows realistic analysis of comparative lighting system performance including interactions with daylighting.

Parker, D. S.; Schrum, L.; Sonne, J. K.; Stedman, T. C.

1996-01-01T23:59:59.000Z

216

A high-efficiency indirect lighting system utilizing the solar 1000 sulfur lamp  

E-Print Network (OSTI)

and Renewable Energy, Office of Building Technology, State andand Renewable Energy, Office of Building Technology, State and

Siminovitch, Michael; Gould, C.; Page, E.

1997-01-01T23:59:59.000Z

217

Contribution to the numerical study of turbulence in high intensity discharge lamps  

SciTech Connect

We present in this paper a comparison between results obtained with a laminar and turbulent models for high-pressure mercury arc. The two models are based on the resolution of bidimensional time-dependent equations by a semi-implicit finite-element code. The numerical computation of turbulent model is solved with large eddy simulation model; this approach takes into account the various scales of turbulence by a filtering method on each scale. The results show the quantitative influence of turbulence on the flow fields and also the difference between laminar and turbulent effects on the dynamic thermal behaviour and on the characteristics of the discharge.

Kaziz, S.; Ben Ahmed, R.; Helali, H.; Gazzah, H.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, 5019 route de Kairouan Monastir (Tunisia)

2011-07-15T23:59:59.000Z

218

Whole Product Performance for 2X High-Efficiency Incandescent Lamps  

Science Conference Proceedings (OSTI)

FirstEnergy (FE) approached EPRI’s Lighting Lab in 2011 to validate the performance of a newly developed “2X” incandescent lighting technology developed by a manufacturing company in their service territory. This manufacturer claimed that their product was identical in light output, but twice (2X) as efficient as traditional 100W incandescent bulbs. In collaboration with FE, EPRI conducted a series of tests to independently verify the energy and photometric performance of this ...

2012-11-12T23:59:59.000Z

219

Tungsten Lamps as an Affordable Light Source for Testing of Photovoltaic Cells  

Science Conference Proceedings (OSTI)

An improved Tungsten light source system for photovoltaic cell testing made from low-cost, commercially available materials is presented as an alternative to standard expensive testing equipment. In this work, spectral correction of the Tungsten light ... Keywords: I-V measurement, Light source, Photovoltaic, Testing

Jeydmer Aristizabal; Badr Omrane; Clint Landrock; Sasan Vosoogh-Grayli; Yindar Chuo; Jasbir N. Patel; Bozena Kaminska; Carlo Menon

2011-06-01T23:59:59.000Z

220

Characterization of a high-gain picosecond flash-lamp-pumped Nd:YAG regenerative amplifier  

Science Conference Proceedings (OSTI)

We evaluate the performance of a novel 10-Hz picosecond Nd:YAG regenerative amplifier configured as a self-filtering unstable resonator. Pulse energies of approx.60 mJ in approx.100 psec at 1.06 ..mu..m are achieved using a single 6-mm-diameter Nd:YAG rod, while mode-matching requirements are minimized.

Dawson, M.D.; Schroeder, W.A.; Norwood, D.P.; Smirl, A.L.; Weston, J.; Ettelbrick, R.N.; Aubert, R.

1988-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

RFIG lamps: interacting with a self-describing world via photosensing wireless tags and projectors  

Science Conference Proceedings (OSTI)

This paper describes how to instrument the physical world so that objects become self-describing, communicating their identity, geometry, and other information such as history or user annotation. The enabling technology is a wireless tag which acts as ... Keywords: augmented reality, human-machine communication, image stabilization, projector, radio frequency identification, stucture from motion

Ramesh Raskar; Paul Beardsley; Jeroen van Baar; Yao Wang; Paul Dietz; Johnny Lee; Darren Leigh; Thomas Willwacher

2005-07-01T23:59:59.000Z

222

RFIG lamps: interacting with a self-describing world via photosensing wireless tags and projectors  

Science Conference Proceedings (OSTI)

This paper describes how to instrument the physical world so that objects become self-describing, communicating their identity, geometry, and other information such as history or user annotation. The enabling technology is a wireless tag which acts as ... Keywords: augmented reality, human-machine communication, image stabilization, projector, radio frequency identification, stucture from motion

Ramesh Raskar; Paul Beardsley; Jeroen van Baar; Yao Wang; Paul Dietz; Johnny Lee; Darren Leigh; Thomas Willwacher

2006-07-01T23:59:59.000Z

223

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry  

NLE Websites -- All DOE Office Websites (Extended Search)

News Latest News Videos Community Relations Past Projects Rebuilding Together Energy Teams Events Past Events For The Media Seminars Past Seminars Speakers Distinguished...

224

Defining the Effectiveness of UV Lamps Installed in Circulating Air Ductwork  

SciTech Connect

Ultraviolet; UV; UVC; UVGI; HVAC; ductwork; mold; fungus; effectiveness; microbial; dose; irradiance; reflectance; bacillis; aspergillis

Douglas VanOsdell; Karin Foarde

2002-11-30T23:59:59.000Z

225

NIST Spectrum of Th-Ar Hollow Cathode Lamps in the 691 nm ...  

Science Conference Proceedings (OSTI)

... such as the Cryogenic High-Resolution IR Echelle Spectrograph ([CRIRES]), ESO's new IR spectrograph at the Very Large Telescope in Chile. ...

2011-12-13T23:59:59.000Z

226

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

E-Print Network (OSTI)

Green Lights Program to promote efficient lighting products through public education, consumer incentives, national product testing, and investments

Lin, Jiang

2002-01-01T23:59:59.000Z

227

RFIG lamps: interacting with a self-describing world via photosensing wireless tags and projectors  

Science Conference Proceedings (OSTI)

This paper describes how to instrument the physical world so that objects become self-describing, communicating their identity, geometry, and other information such as history or user annotation. The enabling technology is a wireless tag which acts as ... Keywords: augmented reality, human-machine communication, image stabilization, projector, radio frequency identification, stucture from motion

Ramesh Raskar; Paul Beardsley; Jeroen van Baar; Yao Wang; Paul Dietz; Johnny Lee; Darren Leigh; Thomas Willwacher

2004-08-01T23:59:59.000Z

228

DOE Requires Manufacturer and Labeler to Cease Sale of Incandescent Reflector Lamps  

Energy.gov (U.S. Department of Energy (DOE))

DOE has issued Notices of Non-Compliance Determination to Westinghouse Lighting Corporation and Fuzhou Sunlight Lighting Electrical Appliance Company requiring that they halt the sale of 8 basic...

229

Lumen Maintenance Testing of the Philips 60-Watt Replacement Lamp L Prize Entry  

Science Conference Proceedings (OSTI)

This paper describes testing conducted to evaluate the Philips' L Prize award winning 60-watt LED replacement product's ability to meet the lifetime/lumen maintenance requirement of the competition, which was: "having 70 percent of the lumen value under subparagraph (A) [producing a luminous flux greater than 900 lumens] exceeding 25,000 hours under typical conditions expected in residential use." A custom test apparatus was designed and constructed for this testing and a statistical approach was developed for use in evaluating the test results. This will be the only publicly available, third-party data set of long-term LED product operation.

Gordon, Kelly L.; Hafen, Ryan P.; Hathaway, John E.; McCullough, Jeffrey J.

2012-09-01T23:59:59.000Z

230

LAMP-TR-108 NOVEMBER 2003 UMIACS-TR-2003-109  

E-Print Network (OSTI)

the right sorts of pages - Enter the Altavista search terms - Enter the words that identify sentences structure. Click Proceed to Search. Then enter the description "The ADJer the NP the ADJer the NP" and click to the LSE's My Collections screen. Paste or type the query you copied into the LSE's Altavista Search Terms

Gruner, Daniel S.

231

Research on the Best Market Applications for LightLab Energy-Saving Lamps.  

E-Print Network (OSTI)

?? Nowadays, lighting represents 20% of the global electricity consumption. Light can be produced using different technologies but more than 100 years after its invention,… (more)

Vilalta Cea, Raul

2010-01-01T23:59:59.000Z

232

Accurate modelling of Roman lamps in conimbriga using high dynamic range  

Science Conference Proceedings (OSTI)

The Human Visual System has a remarkable ability to acquire colour and contrast of all the things that surround us. This is particularly evident in extreme lighting conditions such as bright light or dark environments. However, it is simply not possible ...

A. Gonçalves; L. Magalhães; J. Moura; A. Chalmers

2008-12-01T23:59:59.000Z

233

Phase II report on energy efficient electronic ballasts for a two-40 watt fluorescent lamp system  

SciTech Connect

The Department of Energy (DOE) has established a project aimed at accelerating the commercialization of electronic ballasts. During the Phase I portion of the project a small quantity of ballasts and other hardware were delivered for independent testing. Results verified the claims for energy savings and other unique and advantageous features of the electronic ballast. Phase II, a large scale field demonstration, is reported. The demonstration is being conducted by LBL and the Pacific Gas and Electric Company in the PG and E headquarters building in downtown San Fracisco. The test demonstration hardware is being procured. Included are two models of energy saving ballasts; two dimmer systems that show the potential for additional power savings; and, two models of Automatic Emergency Light Systems. Installation of ballasts and the beginning of actual test operations were originally scheduled for February 1978. However, slippages in hardware deliveries have caused a three-month delay. Testing at PG and E is now scheduled to begin in June 1978. Even though broad scale results from the Phase II demonstration at PG and E are not yet available, performance and versatility advantages of the electronic ballast have been demonstrated. They offer a clear incentive to the industry for development and production of reliable hardware that will be competitively saleable on a long term cost-of-lighting basis.

1978-07-01T23:59:59.000Z

234

Energy Basics: Incandescent Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

The three most common types of incandescent lamps are: Standard incandescent lamps Energy-Saving Incandescent (or Halogen) Reflector lamps Standard Incandescent Lamps Known as...

235

Incandescent Lighting | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

or pear-shaped A-19 lamps Energy-saving or halogen A-19 lamps Reflector or parabolic reflector (PAR) lamps, sometimes called "flood" or "spot" lamps Standard...

236

Over the past decade, lighting became more efficient across ...  

U.S. Energy Information Administration (EIA)

"Other" includes light-emitting diode (LED) lamps as well as other lamps such as fiber optic lights, induction lamps, and lamps of unknown ...

237

Federal Energy Management Program: Energy Cost Calculator for...  

NLE Websites -- All DOE Office Websites (Extended Search)

8000 hours Number of lamps in retrofit project Hours operating per week hours Average cost of electricity 0.06 kWh Relamper labor costs hr Time taken to retrofit all lamps...

238

Photonics in Industry: Water Disinfection and Contamination Treatment Dr. Gordon Knight  

E-Print Network (OSTI)

lamps, light emitting diodes, and flash lamps. Optimizing the irradiance and wavelength of the light

Czarnecki, Krzysztof

239

An interface to aid rural health workers in the preliminary diagnosis of cataract at the slit lamp using LOCS III  

Science Conference Proceedings (OSTI)

In India there is an inequitable distribution of wealth and resources; while 70% of population lives in villages, about 80 % of ophthalmologists practice in cities [4]. India has 1 ophthalmologist per 100,000 of its population [4] and this ratio is even ... Keywords: graphical user interfaces, healthcare, interaction styles, screen design, user-centered design

Satyendra Kumar Nainwal

2007-04-01T23:59:59.000Z

240

The LAMP-like protein p67 plays an essential role in the lysosome of African trypanosomes  

E-Print Network (OSTI)

: ( ) ( ) ( ) ( ) U c U x U U x p p c x + = d dcw w Note that because U is a function of S, in general

Sheridan, Jennifer

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Solid-state semiconductors are better alternatives to arc-lamps for efficient and uniform illumination in minimal access surgery  

E-Print Network (OSTI)

of technical and ergonomic limitations. White light-emitting diodes (LEDs) are energy-efficient solid- state Illumination Á Light-emitting diode Á Minimal access surgery Á Solid-state semiconductor In the 1950s

Rosso, Lula

242

Demonstration Assessment of Light-Emitting Diode (LED) Retrofit Lamps at Intercontinental Hotel in San Francisco, CA  

SciTech Connect

This document is a report of observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy (DOE) GATEWAY Demonstration Program. The program supports demonstrations of high-performance solid-state lighting (SSL) products in order to develop empirical data and experience with in-the-field applications of this advanced lighting technology. The DOE GATEWAY Demonstration Program focuses on providing a source of independent, third-party data for use in decision-making by lighting users and professionals; this data should be considered in combination with other information relevant to the particular site and application under examination. Each GATEWAY Demonstration compares SSL products against the incumbent technologies used in that location. Depending on available information and circumstances, the SSL product may also be compared to alternate lighting technologies. Though products demonstrated in the GATEWAY program have been prescreened and tested to verify their actual performance, DOE does not endorse any commercial product or in any way guarantee that users will achieve the same results through use of these products.

Miller, Naomi J.; Curry, Ku'Uipo J.

2010-11-01T23:59:59.000Z

243

Demonstration Assessment of Light-Emitting Diode (LED) Retrofit Lamps at the Lobby of the Bonneville Power Administration, Portland, OR  

SciTech Connect

This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in the lobby of the Bonneville Power Administration (BPA) headquarters building in Portland, Oregon. The project involved a simple retrofit of 32 track lights used to illuminate historical black-and-white photos and printed color posters from the 1930s and 1940s. BPA is a federal power marketing agency in the Northwestern United States, and selected this prominent location to demonstrate energy efficient light-emitting diode (LED) retrofit options that not only can reduce the electric bill for their customers but also provide attractive alternatives to conventional products, in this case accent lighting for BPA's historical artwork.

Miller, Naomi

2011-07-01T23:59:59.000Z

244

Visible Light Digital Camera --Up to 2.3MP resolution with LED lamps provides sharp images  

E-Print Network (OSTI)

regardless of lighting conditions · Fusion Picture in Picture (PIP) -- Displays thermal image super Marker Function · Auto Hot/Cold spot marker function shows a spot within the area that automatically finds the hottest or coldest spot within the box i-Series Features FLIR i60 -- Scalable Fusion picture

Short, Daniel

245

Analysis, design and optimization of the LCC resonant inverter as a high-intensity discharge lamp ballast  

SciTech Connect

A complete study of the clamped-mode (CM) series-parallel (LCC) resonant inverter together with some of the control-to-output characteristics are presented in this paper. Also, a new control method for the CM LCC resonant inverter is introduced. With this method, the inverter is forced to operate with optimum commutations and without handling reactive energy, thus minimizing both switching and conduction losses. The corresponding design procedure is illustrated with a design example. Finally, some experimental results obtained from a prototype at the laboratory are also shown to validate the analysis and evaluate the proposed control method.

Alonso, J.M.; Blanco, C.; Lopez, E.; Calleja, A.J.; Rico, M. [Univ. de Oviedo, Gijon (Spain). Dept. de Ingenieria Electrica y Electronica

1998-05-01T23:59:59.000Z

246

STATE OF UTAH CONTRACT NUMBER: MA049 October 06, 2010 Page 1 of 82 Includes Codale Lamp and Ballast  

E-Print Network (OSTI)

) = M0 EwMn Ewv (WT ) T-1 k=0 e- r (Wk, Wk+1) I (T n) Ewf (WT )2 exp (-T) T-1 k=0 r (Wk, Wk+1) I (T n) . Sending n and using monotone convergence we obtain that v (w) / Ewf (WT )2 exp (-T) T-1 k=0 r

Capecchi, Mario R.

247

Energy-efficient H. I. D. solid-state ballast: Phase II final report. [150 watt high pressure sodium lamp  

SciTech Connect

The following report presents the results of Phase II, Development of Solid State 150 watt High Pressure Sodium Ballasts. Basically, the objectives of the development program were accomplished, i.e., greater than 90% efficiency, greater than 90% power factor, regulation equivalent to ferro-magnetic ballasts, and energy savings sufficient to warrant the further development of the solid-state HPS ballast for commercial production and marketing. 8 figs., 5 tabs.

1983-06-01T23:59:59.000Z

248

AVERAGE SHIFTED HISTOGRAM  

Science Conference Proceedings (OSTI)

... LET YPPF = XCDF LET XPPF = YCDF. Default: None Synonyms: ASH is a synonym for the AVERAGE SHIFTED HISTOGRAM command. ...

2010-12-06T23:59:59.000Z

249

Average Commercial Price  

U.S. Energy Information Administration (EIA) Indexed Site

Residential Price Average Commercial Price Period: Monthly Annual Download Series History Download Series History Definitions, Sources & Notes Definitions, Sources & Notes...

250

Appliance Standard Program - The FY 2003 Priority -Setting Summary...  

NLE Websites -- All DOE Office Websites (Extended Search)

Fluorescent Lamp Ballasts Electric Motors, 1-200HP Fluorescent Lamps Commercial Oil- and Gas-Fired Packaged Boilers Mobile Home Furnaces High-Intensity Discharge Lamps...

251

Section 5.4.1 Linear Fluorescent Lighting: Greening Federal Facilities...  

NLE Websites -- All DOE Office Websites (Extended Search)

and color temperature. When specifying a lighting sys- tem, be sure that the lamp and ballast are electrically matched and the lamp and fixture optically matched. Fluorescent lamp...

252

average | OpenEI  

Open Energy Info (EERE)

average average Dataset Summary Description This dataset is part of a larger internal dataset at the National Renewable Energy Laboratory (NREL) that explores various characteristics of large solar electric (both PV and CSP) facilities around the United States. This dataset focuses on the land use characteristics for solar facilities that are either under construction or currently in operation. Source Land-Use Requirements for Solar Power Plants in the United States Date Released June 25th, 2013 (7 months ago) Date Updated Unknown Keywords acres area average concentrating solar power csp Density electric hectares km2 land land requirements land use land-use mean photovoltaic photovoltaics PV solar statistics Data application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon Master Solar Land Use Spreadsheet (xlsx, 1.5 MiB)

253

DOE Average Results  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE DOE Average Results FY 12 DOE Target FY 12 Customer Perspective: Customer Satisfaction: -Timeliness 92 88 -Quality 94 92 Effective Service Partnership: -Extent of Customer Satisfaction with the responsiveness, etc. 90 92 Internal Business Perspective: Acquisition Excellence: -Extent to which internal quality control systems are effective 90 88 Most Effective Use of Contracting Approaches to Maximize Efficiency and Cost Effectiveness: Use of Competition: -% of total $'s obligated on competitive acquisitions >$3000 (Agency Level Only) 94 85 -% of acquisition actions competed for actions > $3000 (Agency Level Only) 65 68 Performance Based Acquisition: - % PBA actions relative to total eligible new acquisition actions (applicable to new actions > $25K) 82

254

Evaluating the Impact of the  

E-Print Network (OSTI)

simulated using linear fluorescent lamps with correlated color temperatures of 5000K. Yet, the variability among linear fluorescent lamp systems, which include the lamp, ballast and reflector, is great Linear Fluorescent Lamps Fluorescent lamps are produced in many different forms. Linear fluorescent lamps

Zanibbi, Richard

255

Buildings Energy Data Book: 7.6 Efficiency Standards for Lighting  

Buildings Energy Data Book (EERE)

2 2 Efficiency Standards for Incandescent Reflector Lamps (1) Effective for lamps manufactured after November 1, 1995 and before July 14, 2012 Minimum Nominal Average Lamp Lamp Wattage Efficacy (lm/W) 40-50 10.5 51-66 11.0 67-85 12.5 86-115 14.0 116-155 14.5 156-205 15.0 Effective for lamps manufactured on or after July 14, 2012 Minimum Rated Lamp Rated Average Lamp Lamp Wattage Lamp Spectrum Diameter (in) Voltage (V) Efficacy (lm/W) (2) 40-205 Standard Spectrum >2.5 ≥125 6.8*P^0.27 40-205 Standard Spectrum >2.5 <125 5.9*P^0.27 40-205 Standard Spectrum ≤2.5 ≥125 5.7*P^0.27 40-205 Standard Spectrum ≤2.5 <125 5.0*P^0.27 40-205 Modified Spectrum >2.5 ≥125 5.8*P^0.27 40-205 Modified Spectrum >2.5 <125 5.0*P^0.27 40-205 Modified Spectrum ≤2.5 ≥125 4.9*P^0.27

256

Census Division Number of Average Monthly Average Retail Price...  

Gasoline and Diesel Fuel Update (EIA)

Average Monthly Average Retail Price Average Monthly Bill State Consumers Consumption (kWh) (Cents per Kilowatthour) (Dollar and cents) New England 34,271 67,907 12.55 8,520.25...

257

Mechanistic Evaluation of the Pros and Cons of Digital RT-LAMP for HIV1 Viral Load Quantification on a Microfluidic Device and  

E-Print Network (OSTI)

. We learned the following three lessons from this work: (i) digital amplification technologies with HIV, many of whom live in developing countries and under resource-limited conditions.1 As antire- troviral treatment becomes more widely available, viral resistance to first-line antiretroviral drugs

Ismagilov, Rustem F.

258

The effect of the operation modes of a gas discharge low-pressure amalgam lamp on the intensity of generation of 185 nm UV vacuum radiation  

SciTech Connect

The effect of the discharge current, mercury vapor pressure, and the inert gas pressure on the intensity and efficiency of the 185 nm line generation are considered. The spectra of the UV radiation (vacuum ultraviolet) transmission by protective coatings from the oxides of rare earth metals and aluminum are investigated.

Vasilyak, L. M., E-mail: vasilyak@ihed.ras.ru [Russian Academy of Sciences, Joint Institute of High Temperatures (Russian Federation); Drozdov, L. A., E-mail: lit@npo.lit.ru; Kostyuchenko, S. V.; Sokolov, D. V. [ZAO LIT (Russian Federation); Kudryavtsev, N. N.; Sobur, D. A., E-mail: soburda@gmail.com [Moscow Institute for Physics and Technology (Russian Federation)

2011-12-15T23:59:59.000Z

259

1995-2011 | LS-LAMP IMPACT REPORT uniVersity of neW orLeAns | new orleans, la  

E-Print Network (OSTI)

.S., mathematics, michigan State University, East Lansing, mI m.S., Statistical Science, Baylor University, waco was the second place winner of the 2010 Joint statistical meetings (Jsm) stat Bowl. she was also named oustanding Graduate stu- dent (2010) by Baylor university's Department of statistical sciences. she has also

Kulp, Mark

260

All products of the future clothes, household devices, lamps will contain electronic units. Graduates in Electronic Design Engineering will be able  

E-Print Network (OSTI)

to design the software and elec- tronics of the future, design energy-friendly systems by using clean tech. Graduates in Electronic Design Engineering will be able to design both electronics and system software hardware and software electronics, as well as mathematics and physics, to prototype cutting-edge projects

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Assessment of Electrical, Efficiency, and Photometric Performance of Advanced Lighting Sources: Dimmable Advanced Lighting Technolog ies -- Electronic Light-Emitting Diode (LED) Fixtures, Lamps, and Drivers  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses the dimming performance of light-emitting diode (LED) lighting. Chapter 1 provides a discussion of basic lighting control, the importance of considering power quality in lighting control, lighting control methods and parameters, and the advantages and future of lighting control. Chapter 2 addresses in more depth the dimming methods used in advanced lighting sources and controls for incandescent, fluorescent, high-intensity discharge (HID) and LED sources. Chapter 3 ad...

2008-12-19T23:59:59.000Z

262

Advanced Light Sources  

Science Conference Proceedings (OSTI)

In the generation of artificial light using electric lamps, photometric and color performance have been paramount in lamp design, manufacturing, measurement, lighting design, and visual perception. Many designers and researchers have strived to understand how light and color are generated, related, and to improve them. This has stemmed from the development of incandescent lamps, halogen lamps, linear fluorescent lamps, high-intensity discharge (HID) lamps, and compact fluorescent lamps (CFLs) among other...

2008-03-31T23:59:59.000Z

263

EIA Average Energy Consumption 2005  

U.S. Energy Information Administration (EIA)

Table US8. Average Consumption by Fuels Used, 2005 Physical Units per Household Fuels Used (physical units of consumption per household using the fuel)

264

Grid-Averaged Surface Fluxes  

Science Conference Proceedings (OSTI)

This study examines the inadequacies of formulations for surface fluxes for use in numerical models of atmospheric flow. The difficulty is that numerical models imply spatial averaging over each grid area. Existing formulations am based on the ...

L. Mahrt

1987-08-01T23:59:59.000Z

265

High average power pockels cell  

DOE Patents (OSTI)

A high average power pockels cell is disclosed which reduces the effect of thermally induced strains in high average power laser technology. The pockels cell includes an elongated, substantially rectangular crystalline structure formed from a KDP-type material to eliminate shear strains. The X- and Y-axes are oriented substantially perpendicular to the edges of the crystal cross-section and to the C-axis direction of propagation to eliminate shear strains.

Daly, Thomas P. (Pleasanton, CA)

1991-01-01T23:59:59.000Z

266

Core Measure Average KTR Results  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Measure Measure Average KTR Results FY 12 Target FY 12 DOE M&O CONTRACTOR (KTR) BSC RESULTS FY 2012 Customer Perspective and level of communication provided by the procurement office 95 92 Internal Business Perspective: Assessment (%) of the degree to which the purchasing system is in compliance with stakeholder requirements 97 Local Goals % Delivery on-time (includes JIT, excludes Purchase Cards) 88 84 % of total dollars obligated, on actions > $150K , that were awarded using effective competition 73 Local Goals Rapid Purchasing Techniques: -% of transactions placed by users 77 Local Goals -% of transactions placed through electronic commerce 62 Local Goals Average Cycle Time: -Average cycle time for <= $150K 8 6 to 9 days

267

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 2, Fluorescent lamp ballasts, television sets, room air conditioners, and kitchen ranges and ovens  

SciTech Connect

This document is divided into ``volumes`` B through E, dealing with individual classes of consumer products. Chapters in each present engineering analysis, base case forecasts, projected national impacts of standards, life-cycle costs and payback periods, impacts on manufacturers, impacts of standards on electric utilities, and environmental effects. Supporting appendices are included.

Not Available

1993-11-01T23:59:59.000Z

268

West Texas Intermediate Spot Average ............................  

U.S. Energy Information Administration (EIA) Indexed Site

Crude Oil (dollars per barrel) Crude Oil (dollars per barrel) West Texas Intermediate Spot Average ............................ 102.88 93.42 92.24 87.96 94.34 94.10 105.84 96.30 95.67 95.33 95.67 93.33 94.12 97.64 95.00 Brent Spot Average ........................................................... 118.49 108.42 109.61 110.09 112.49 102.58 110.27 108.29 106.33 105.00 103.00 102.00 111.65 108.41 104.08 Imported Average .............................................................. 108.14 101.18 97.18 97.64 98.71 97.39 103.07 100.03 99.64 99.33 99.69 97.35 101.09 99.85 99.04 Refiner Average Acquisition Cost ...................................... 107.61 101.44 97.38 97.27 101.14 99.45 105.24 100.44 100.15 99.82 100.18 97.83 100.83 101.61 99.50 Liquid Fuels (cents per gallon) Refiner Prices for Resale Gasoline .........................................................................

269

Dixie Electric Membership Corp | Open Energy Information  

Open Energy Info (EERE)

Membership Corp Membership Corp Place Louisiana Utility Id 5202 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes RTO SPP Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 10,001 - 29,000 Average Lumens Per Lamp Lighting 29,002 - 60,000 Average Lumens Per Lamp Lighting 60,000 - 155,000 Average Lumens Per Lamp Lighting 7,000 - 10,000 Average Lumens Per Lamp Lighting Church Schedule (C) Commercial Commercial and Small Power Service Schedule B Commercial Commercial and Small Power Time-of-Use Commercial Farm Home Schedule Residential Large Power Service - Schedule LP Industrial

270

Pre-clinical Measures of Eye Damage (Lens Opacity), Case-control Study of Tuberculosis, and Indicators of Indoor Air Pollution from Biomass Smoke  

E-Print Network (OSTI)

for cooking and heating, and promotion of solar lamps orheating fuel used Main source of light in the house Electricity Kerosene lamp Solarsolar lamps. Key words: biomass fuel, cooking-fuel smoke, heating,

Pokhrel, Amod Kumar

2010-01-01T23:59:59.000Z

271

ComEd - Business Instant Lighting Discounts Program (Illinois...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

lamps include screw-in CFLs, reduced wattage T8 and T5 linear fluorescents, screw-in LED lamps and LED trim kits and reduced wattage ceramic metal halide lamps. All incentives...

272

Barron Electric Cooperative - Energy Star Appliance & Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Terminal Heat Pump: 150ton CFL: 1 -5 Per Lamp CFL Fixtures-Hardwired: 5 Per Unit LED Lamp (least 5 watts): 2 Per Lamp LED Security Lighting: 15 Per Fixture Occupancy...

273

Browse wiki | Open Energy Information  

Open Energy Info (EERE)

for each lighting unit will be computed as: Lamps rated cpacity per lamp including Ballast X 0.097pacity per lamp including Ballast X 0.097 OpenEIUtilityRate...

274

Variable Average Absolute Percent Differences  

U.S. Energy Information Administration (EIA) Indexed Site

Variable Variable Average Absolute Percent Differences Percent of Projections Over- Estimated Gross Domestic Product Real Gross Domestic Product (Average Cumulative Growth)* (Table 2) 1.0 42.6 Petroleum Imported Refiner Acquisition Cost of Crude Oil (Constant $) (Table 3a) 35.2 18.6 Imported Refiner Acquisition Cost of Crude Oil (Nominal $) (Table 3b) 34.7 19.7 Total Petroleum Consumption (Table 4) 6.2 66.5 Crude Oil Production (Table 5) 6.0 59.6 Petroleum Net Imports (Table 6) 13.3 67.0 Natural Gas Natural Gas Wellhead Prices (Constant $) (Table 7a) 30.7 26.1 Natural Gas Wellhead Prices (Nominal $) (Table 7b) 30.0 27.1 Total Natural Gas Consumption (Table 8) 7.8 70.2 Natural Gas Production (Table 9) 7.1 66.0 Natural Gas Net Imports (Table 10) 29.3 69.7 Coal Coal Prices to Electric Generating Plants (Constant $)** (Table 11a)

275

Achronal averaged null energy condition  

Science Conference Proceedings (OSTI)

The averaged null energy condition (ANEC) requires that the integral over a complete null geodesic of the stress-energy tensor projected onto the geodesic tangent vector is never negative. This condition is sufficient to prove many important theorems in general relativity, but it is violated by quantum fields in curved spacetime. However there is a weaker condition, which is free of known violations, requiring only that there is no self-consistent spacetime in semiclassical gravity in which ANEC is violated on a complete, achronal null geodesic. We indicate why such a condition might be expected to hold and show that it is sufficient to rule out closed timelike curves and wormholes connecting different asymptotically flat regions.

Graham, Noah; Olum, Ken D. [Department of Physics, Middlebury College, Middlebury, Vermont 05753 (United States) and Center for Theoretical Physics, Laboratory for Nuclear Science, and Department of Physics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Institute of Cosmology, Department of Physics and Astronomy, Tufts University, Medford, Massachusetts 02155 (United States)

2007-09-15T23:59:59.000Z

276

Achronal averaged null energy condition  

E-Print Network (OSTI)

The averaged null energy condition (ANEC) requires that the integral over a complete null geodesic of the stress-energy tensor projected onto the geodesic tangent vector is never negative. This condition is sufficient to prove many important theorems in general relativity, but it is violated by quantum fields in curved spacetime. However there is a weaker condition, which is free of known violations, requiring only that there is no self-consistent space-time in semiclassical gravity in which ANEC is violated on a complete, {\\em achronal} null geodesic. We indicate why such a condition might be expected to hold and show that it is sufficient to rule out wormholes and closed timelike curves.

Noah Graham; Ken D. Olum

2007-05-22T23:59:59.000Z

277

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

have been required to comply with the Department of Energy (DOE) energy conservation standards for fluorescent lamp ballasts since 1990. Fluorescent lamp ballasts control electric...

278

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2011  

E-Print Network (OSTI)

The Effect of Efficiency Standards on Water Use and Water1989. Lamp Efficiency Standards for Massachusetts: AnalysisNational Efficiency Standards for Lamps, Motors, Showerheads

Meyers, Stephen

2013-01-01T23:59:59.000Z

279

ON-SITE DEMONSTRATION PROCEDURE FOR SOLID-STATE FLUORESCENT BALLAST  

E-Print Network (OSTI)

state ballast supplies electrical power to the lamp at acan transform the input electrical power to the lamp morethe measurement of electrical power, voltage, and current if

Verderber, Rudy

2013-01-01T23:59:59.000Z

280

EA-1881: Energy Conservation Program: Energy Conservation Standards...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts EA-1881: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp...

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Browse wiki | Open Energy Information  

Open Energy Info (EERE)

of energy-saving Compact Fluorescent Light Bulbs + , solar-powered lights + , LED bulbs + , auto lamps and other speciality lamps. + , Nanhai + , Guangdong Province + ,...

282

Glossary - U.S. Energy Information Administration (EIA)  

U.S. Energy Information Administration (EIA)

Included in this category are the familiar screw-in light bulbs, as well as somewhat more efficient lamps, such as tungsten halogen lamps, reflector ...

283

SSL Roadmap  

NLE Websites -- All DOE Office Websites (Extended Search)

new jobs. For the most part, LEDs will displace point sources such as incandescent lamps (light- bulbs), while OLEDs will displace area sources such as fluorescent lamps. OLEDs...

284

Federal Energy Management Program: Federal Procurement of Energy...  

NLE Websites -- All DOE Office Websites (Extended Search)

industrial luminaires and many types of exterior lighting. ENERGY STAR covers light bulbs, including compact fluorescent lamps and LED lamps, and light fixtures, including a...

285

Catalog of DC Appliances and Power Systems  

E-Print Network (OSTI)

AC LEDs, particularly for lower luminosity bulbs. Efficacy (bulb or tube, a compact fluorescent lamp typically includes an integral ballast, as do HID lamps, and an LED

Garbesi, Karina

2012-01-01T23:59:59.000Z

286

Federal Energy Management Program: Federal Energy Efficiency...  

NLE Websites -- All DOE Office Websites (Extended Search)

Fluorescent Tube Lamps FEMP temporarily suspended its energy efficiency requirements for fluorescent tube lamps as it evaluates the market impact of the pending 2012 minimum...

287

Energy Basics: Fluorescent Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

& Cooling Water Heating Fluorescent Lighting Fluorescent lamps use 25%-35% of the energy used by incandescent lamps to provide the same amount of illumination (efficacy of...

288

NIST Global Standards Information Europe  

Science Conference Proceedings (OSTI)

... and electronic household and office equipment; set-top-boxes; electric motors; wet-rotor pumps; directional lamps, light emitting diode lamps and ...

289

xml version="1.0" encoding="UTF-8"?>  

Science Conference Proceedings (OSTI)

... and electronic household and office equipment; set-top-boxes; electric motors; wet-rotor pumps; directional lamps, light emitting diode lamps and ...

290

NIST Global Standards Information Switzerland  

Science Conference Proceedings (OSTI)

... and electronic household and office equipment; set-top-boxes; electric motors; wet-rotor pumps; directional lamps, light emitting diode lamps and ...

291

U.S. Energy Information Administration (EIA) - Sector  

Annual Energy Outlook 2012 (EIA)

incandescent bulbs. High-performance incandescent, compact fluorescent, and light-emitting diode (LED) lamps continue to replace low-efficacy incandescent lamps. In 2035,...

292

NIST: Atomic Spectroscopy Group - Optogalvanic Reference ...  

Science Conference Proceedings (OSTI)

... Changes in the lamp current that occur when a resonance is achieved are detected by a drop in voltage across the lamp's ballast resistor with a lock ...

2010-10-05T23:59:59.000Z

293

Spectral and Parametric Averaging for Integrable Systems  

E-Print Network (OSTI)

We analyze two theoretical approaches to ensemble averaging for integrable systems in quantum chaos - spectral averaging and parametric averaging. For spectral averaging, we introduce a new procedure - rescaled spectral averaging. Unlike traditional spectral averaging, it can describe the correlation function of spectral staircase and produce persistent oscillations of the interval level number variance. Parametric averaging, while not as accurate as rescaled spectral averaging for the correlation function of spectral staircase and interval level number variance, can also produce persistent oscillations of the global level number variance and better describes saturation level rigidity as a function of the running energy. Overall, it is the most reliable method for a wide range of statistics.

Tao Ma; R. A. Serota

2013-06-03T23:59:59.000Z

294

Types of Lighting in Commercial Buildings - Lighting Characteristics  

U.S. Energy Information Administration (EIA) Indexed Site

Characteristics of Lighting Types Characteristics of Lighting Types Efficacy Efficacy is the amount of light produced per unit of energy consumed, expressed in lumens per watt (lm/W). Lamps with a higher efficacy value are more energy efficient. Average Rated Life The average rated life of a particular type of lamp is defined by the number of hours when 50 percent of a large sample of that type of lamp has failed. Color Rendering Index (CRI) The CRI is a measurement of a light source's accuracy in rendering different colors when compared to a reference light source. The highest attainable CRI is 100. Lamps with CRIs above 70 are typically used in office and living environments. Correlated Color Temperature (CCT) The CCT is an indicator of the "warmth" or "coolness" of the color

295

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

High-Intensity Discharge Lamps High-Intensity Discharge Lamps Sign up for e-mail updates on regulations for this and other products There are currently no energy conservation standards for high-intensity discharge (HID) lamps. HID lamps are electric discharge lamps and include high-pressure sodium, mercury vapor, and metal halide lamps. HID lamps require an HID ballast to start and regulate electric current flow through the lamp. HID lamps are used in street and roadway lighting, area lighting such as for parking lots and plazas, industrial and commercial building interior lighting, security lighting for commercial, industrial, and residential spaces, and landscape lighting. The Standards and Test Procedures for this product are related to Rulemaking for High Intensity Discharge Lamps Energy Conservation Standard and Rulemaking for High Intensity Discharge Lamps Test Procedures.

296

Town of Centerville, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Indiana (Utility Company) Indiana (Utility Company) Jump to: navigation, search Name Town of Centerville Place Indiana Utility Id 3230 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png City Commercial Commercial City Residential Residential General Power Commercial Rural Commercial Commercial Rural Residential Residential Security Lights: 100 Watt Lamp Lighting Security Lights: 175 Watt Lamp Lighting Security Lights: 250 Watt Lamp Lighting Security Lights: 400 Watt Lamp Lighting Average Rates Residential: $0.0843/kWh

297

Mohawk Municipal Comm | Open Energy Information  

Open Energy Info (EERE)

Municipal Comm Municipal Comm Jump to: navigation, search Name Mohawk Municipal Comm Place New York Utility Id 12759 Utility Location Yes Ownership M NERC Location NPCC Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Industrial Rate Industrial Large Commercial Commercial Public Street Lighting Lighting Security Lighting 150 w lamp Lighting Security Lighting 175 w lamp Lighting Security Lighting 250 w lamp Lighting Security Lighting 400 w lamp Lighting Single-Phase Residential Residential Small Commercial Business Commercial Average Rates Residential: $0.0366/kWh

298

Buildings Energy Data Book: 7.7 Efficiency Standards for Lighting  

Buildings Energy Data Book (EERE)

Efficiency Standards for Lighting Efficiency Standards for Lighting March 2011 7.7.2 Efficiency Standards for General Service Fluorescent Lamps Effective for products manufactured before July 14, 2012 Minimum Nominal Lamp Average Lamp Lamp Type (1) Wattage (W) Minimum CRI Efficacy (lm/W) Effective Date 4-Foot Medium Bipin >35 69 75.0 November 1, 1995 4-Foot Medium Bipin 45 75.0 November 1, 1995 2-Foot U-Shaped >35 69 68.0 November 1, 1995 2-Foot U-Shaped 45 64.0 November 1, 1995 8-Foot Slimline >65 69 80.0 May 1, 1994 8-Foot Slimline 45 80.0 May 1, 1994 8-Foot High Output >100 69 80.0 May 1, 1994 8-Foot High Output 45 80.0 May 1, 1994 Effective for products manufactured on or after July 14, 2012 Minimum Correlated Color Average Lamp Lamp Type Temperature (K) Efficacy (lm/W) 4-Foot Medium Bipin 89 4-Foot Medium Bipin 88 2-Foot U-Shaped

299

Buildings Energy Data Book: 7.6 Efficiency Standards for Lighting  

Buildings Energy Data Book (EERE)

1 1 Efficiency Standards for General Service Fluorescent Lamps Effective for products manufactured before July 14, 2012 Minimum Nominal Lamp Average Lamp Lamp Type (1) Wattage (W) Minimum CRI Efficacy (lm/W) Effective Date 4-Foot Medium Bipin >35 69 75.0 November 1, 1995 4-Foot Medium Bipin ≤35 45 75.0 November 1, 1995 2-Foot U-Shaped >35 69 68.0 November 1, 1995 2-Foot U-Shaped ≤35 45 64.0 November 1, 1995 8-Foot Slimline >65 69 80.0 May 1, 1994 8-Foot Slimline ≤65 45 80.0 May 1, 1994 8-Foot High Output >100 69 80.0 May 1, 1994 8-Foot High Output ≤100 45 80.0 May 1, 1994 Effective for products manufactured on or after July 14, 2012 Minimum Correlated Color Average Lamp Lamp Type Temperature (K) Efficacy (lm/W) 4-Foot Medium Bipin ≤4,500 89 4-Foot Medium Bipin >4,500 and ≤7,000 88

300

Acoustic features of song categories and their possible implications for communication in the common  

E-Print Network (OSTI)

; redwing, Turdus iliacus, Lampe & Espmark, 1987). Furthermore, playback experiments in several species have

Amrhein, Valentin

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Preface In recent decades we have witnessed the enormous impact of scientific computing  

E-Print Network (OSTI)

, furniture, lamps, small appliances, curtains, dishes, and more Moon Zoom 813 Pacific Avenue, Santa Cruz 831

Buscaglia, Gustavo C.

302

1.0. Semiconductor Diodes 1 of 27 1.2 Ideal Diode  

E-Print Network (OSTI)

-high efficiency light emitting diode lamps. As an educational institution, DTCC has shown a serious commitment

Allen, Gale

303

Arnold Schwarzenegger LIGHTING RESEARCH PROGRAM  

E-Print Network (OSTI)

fluorescent task lamp. The prototype used commercially available materials: 1watt light emitting diodes to the mounting board. Development of LightEmitting Diode Task Lamp using Advanced Technologies: Prototype 2 lightemitting diode task lamp. The problem of developing an energy efficient light emitting diode task lamp

304

EA-1881: Finding of No Significant Impact  

Energy.gov (U.S. Department of Energy (DOE))

Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts (October 2011)

305

EA-1881: Final Environmental Assessment  

Energy.gov (U.S. Department of Energy (DOE))

Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts (October 2011)

306

Average Stock Levels: Crude Market & Propane  

U.S. Energy Information Administration (EIA)

This graph shows that propane was not alone in experiencing excess supply in 1998 and extraordinary stock builds. Note that the graph shows average stock levels ...

307

Optimization Online - String-Averaging Projected Subgradient ...  

E-Print Network (OSTI)

Aug 29, 2013 ... Optimization Online. String-Averaging Projected Subgradient Methods for Constrained Minimization. Yair Censor(yair ***at*** math.haifa.ac.il)

308

Dynamic Multiscale Averaging (DMA) of Turbulent Flow  

SciTech Connect

A new approach called dynamic multiscale averaging (DMA) for computing the effects of turbulent flow is described. The new method encompasses multiple applications of temporal and spatial averaging, that is, multiscale operations. Initially, a direct numerical simulation (DNS) is performed for a relatively short time; it is envisioned that this short time should be long enough to capture several fluctuating time periods of the smallest scales. The flow field variables are subject to running time averaging during the DNS. After the relatively short time, the time-averaged variables are volume averaged onto a coarser grid. Both time and volume averaging of the describing equations generate correlations in the averaged equations. These correlations are computed from the flow field and added as source terms to the computation on the next coarser mesh. They represent coupling between the two adjacent scales. Since they are computed directly from first principles, there is no modeling involved. However, there is approximation involved in the coupling correlations as the flow field has been computed for only a relatively short time. After the time and spatial averaging operations are applied at a given stage, new computations are performed on the next coarser mesh using a larger time step. The process continues until the coarsest scale needed is reached. New correlations are created for each averaging procedure. The number of averaging operations needed is expected to be problem dependent. The new DMA approach is applied to a relatively low Reynolds number flow in a square duct segment. Time-averaged stream-wise velocity and vorticity contours from the DMA approach appear to be very similar to a full DNS for a similar flow reported in the literature. Expected symmetry for the final results is produced for the DMA method. The results obtained indicate that DMA holds significant potential in being able to accurately compute turbulent flow without modeling for practical engineering applications.

Richard W. Johnson

2012-09-01T23:59:59.000Z

309

Bayesian curve estimation by model averaging  

Science Conference Proceedings (OSTI)

A Bayesian approach is used to estimate a nonparametric regression model. The main features of the procedure are, first, the functional form of the curve is approximated by a mixture of local polynomials by Bayesian model averaging (BMA), second, the ... Keywords: BIC criterion, Bayesian model averaging, Local polynomial regression, Nonparametric curve fitting, Robustness

Daniel Peña; Dolores Redondas

2006-02-01T23:59:59.000Z

310

Property:SalinityAverage | Open Energy Information  

Open Energy Info (EERE)

SalinityAverage SalinityAverage Jump to: navigation, search Property Name SalinityAverage Property Type Number Description Mean average of the low and high end measurements of the salinity [ppm] of the fluid. This is a property of type Page. Subproperties This property has the following 1 subproperty: C Coso Geothermal Area Pages using the property "SalinityAverage" Showing 19 pages using this property. A Amedee Geothermal Area + 975 + B Beowawe Hot Springs Geothermal Area + 700 + Blue Mountain Geothermal Area + 4300 + Brady Hot Springs Geothermal Area + 3500 + C Chena Geothermal Area + 325 + D Desert Peak Geothermal Area + 6700 + Dixie Valley Geothermal Area + 2295 + E East Mesa Geothermal Area + 3750 + G Geysers Geothermal Area + 217 + K Kilauea East Rift Geothermal Area + 18750 +

311

Data:030d7f8f-08e0-45c2-96d4-b41e1471da39 | Open Energy Information  

Open Energy Info (EERE)

f8f-08e0-45c2-96d4-b41e1471da39 f8f-08e0-45c2-96d4-b41e1471da39 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Barron, Wisconsin (Utility Company) Effective date: 2009/07/15 End date if known: Rate name: Ms-1 Street and Security Lighting Service: 150 W HPS(Steel Pole) Sector: Lighting Description: Application: This schedule will be applied to municipal street lighting and private security lighting. The utility will furnish, install, and maintain all lighting units. Metering: In lieu of metering each lamp unit, the utility will meter one or more of each size and type of lamp unit that operates for a similar time period each month. Each unit of the same size, type and on-time period shall be billed the average amount of energy as used by the metered unit(s) of the same size, type and on-time period. Pole Charges: Wood - Distribution $1.00 per lamp per month Wood- Stand Alone $3.25 per lamp per month Fiberglass $6.25 per lamp per month Steel $8.00 per lamp per month

312

Data:37e3c29a-54a7-4f47-bd70-d81020dba005 | Open Energy Information  

Open Energy Info (EERE)

e3c29a-54a7-4f47-bd70-d81020dba005 e3c29a-54a7-4f47-bd70-d81020dba005 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Barron, Wisconsin (Utility Company) Effective date: 2009/07/15 End date if known: Rate name: Ms-1 Street and Security Lighting Service: 400 W MV(Wood Pole-Distribution) Sector: Lighting Description: Application: This schedule will be applied to municipal street lighting and private security lighting. The utility will furnish, install, and maintain all lighting units. Metering: In lieu of metering each lamp unit, the utility will meter one or more of each size and type of lamp unit that operates for a similar time period each month. Each unit of the same size, type and on-time period shall be billed the average amount of energy as used by the metered unit(s) of the same size, type and on-time period. Pole Charges: Wood - Distribution $1.00 per lamp per month Wood- Stand Alone $3.25 per lamp per month Fiberglass $6.25 per lamp per month Steel $8.00 per lamp per month

313

Data:180d70ba-dca2-40cd-ae63-e580136b855f | Open Energy Information  

Open Energy Info (EERE)

d70ba-dca2-40cd-ae63-e580136b855f d70ba-dca2-40cd-ae63-e580136b855f No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Barron, Wisconsin (Utility Company) Effective date: 2009/07/15 End date if known: Rate name: Ms-1 Street and Security Lighting Service: 100 W HPS(Steel Pole) Sector: Lighting Description: Application: This schedule will be applied to municipal street lighting and private security lighting. The utility will furnish, install, and maintain all lighting units. Metering: In lieu of metering each lamp unit, the utility will meter one or more of each size and type of lamp unit that operates for a similar time period each month. Each unit of the same size, type and on-time period shall be billed the average amount of energy as used by the metered unit(s) of the same size, type and on-time period. Pole Charges: Wood - Distribution $1.00 per lamp per month Wood- Stand Alone $3.25 per lamp per month Fiberglass $6.25 per lamp per month Steel $8.00 per lamp per month

314

Data:6326a31e-00cd-4f2f-86e7-e6a764fc8e3c | Open Energy Information  

Open Energy Info (EERE)

a31e-00cd-4f2f-86e7-e6a764fc8e3c a31e-00cd-4f2f-86e7-e6a764fc8e3c No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Barron, Wisconsin (Utility Company) Effective date: 2009/07/15 End date if known: Rate name: Ms-1 Street and Security Lighting Service: 250 W HPS(Wood Pole-Stand Alone) Sector: Lighting Description: Application: This schedule will be applied to municipal street lighting and private security lighting. The utility will furnish, install, and maintain all lighting units. Metering: In lieu of metering each lamp unit, the utility will meter one or more of each size and type of lamp unit that operates for a similar time period each month. Each unit of the same size, type and on-time period shall be billed the average amount of energy as used by the metered unit(s) of the same size, type and on-time period. Pole Charges: Wood - Distribution $1.00 per lamp per month Wood- Stand Alone $3.25 per lamp per month Fiberglass $6.25 per lamp per month Steel $8.00 per lamp per month

315

Data:3ca0ce5f-9e3e-46d8-a86c-2264f6dff26c | Open Energy Information  

Open Energy Info (EERE)

ce5f-9e3e-46d8-a86c-2264f6dff26c ce5f-9e3e-46d8-a86c-2264f6dff26c No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Barron, Wisconsin (Utility Company) Effective date: 2009/07/15 End date if known: Rate name: Ms-1 Street and Security Lighting Service: 175 W MV(Wood Pole-Stand Alone) Sector: Lighting Description: Application: This schedule will be applied to municipal street lighting and private security lighting. The utility will furnish, install, and maintain all lighting units. Metering: In lieu of metering each lamp unit, the utility will meter one or more of each size and type of lamp unit that operates for a similar time period each month. Each unit of the same size, type and on-time period shall be billed the average amount of energy as used by the metered unit(s) of the same size, type and on-time period. Pole Charges: Wood - Distribution $1.00 per lamp per month Wood- Stand Alone $3.25 per lamp per month Fiberglass $6.25 per lamp per month Steel $8.00 per lamp per month

316

Data:274b7807-4b37-47a7-9201-2a757af2e2cf | Open Energy Information  

Open Energy Info (EERE)

807-4b37-47a7-9201-2a757af2e2cf 807-4b37-47a7-9201-2a757af2e2cf No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Barron, Wisconsin (Utility Company) Effective date: 2009/07/15 End date if known: Rate name: Ms-1 Street and Security Lighting Service: 400 W MV(Fiberglass Pole) Sector: Lighting Description: Application: This schedule will be applied to municipal street lighting and private security lighting. The utility will furnish, install, and maintain all lighting units. Metering: In lieu of metering each lamp unit, the utility will meter one or more of each size and type of lamp unit that operates for a similar time period each month. Each unit of the same size, type and on-time period shall be billed the average amount of energy as used by the metered unit(s) of the same size, type and on-time period. Pole Charges: Wood - Distribution $1.00 per lamp per month Wood- Stand Alone $3.25 per lamp per month Fiberglass $6.25 per lamp per month Steel $8.00 per lamp per month

317

Data:5aa5f3ef-6fd6-4b77-9723-04528f59bc49 | Open Energy Information  

Open Energy Info (EERE)

f3ef-6fd6-4b77-9723-04528f59bc49 f3ef-6fd6-4b77-9723-04528f59bc49 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Barron, Wisconsin (Utility Company) Effective date: 2009/07/15 End date if known: Rate name: Ms-1 Street and Security Lighting Service: 100 W HPS(Wood Pole-Distribution) Sector: Lighting Description: Application: This schedule will be applied to municipal street lighting and private security lighting. The utility will furnish, install, and maintain all lighting units. Metering: In lieu of metering each lamp unit, the utility will meter one or more of each size and type of lamp unit that operates for a similar time period each month. Each unit of the same size, type and on-time period shall be billed the average amount of energy as used by the metered unit(s) of the same size, type and on-time period. Pole Charges: Wood - Distribution $1.00 per lamp per month Wood- Stand Alone $3.25 per lamp per month Fiberglass $6.25 per lamp per month Steel $8.00 per lamp per month

318

Data:5bc59221-85d8-46e6-b9dd-201411dcb8fd | Open Energy Information  

Open Energy Info (EERE)

9221-85d8-46e6-b9dd-201411dcb8fd 9221-85d8-46e6-b9dd-201411dcb8fd No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Barron, Wisconsin (Utility Company) Effective date: 2009/07/15 End date if known: Rate name: Ms-1 Street and Security Lighting Service: 175 W MV(Steel Pole) Sector: Lighting Description: Application: This schedule will be applied to municipal street lighting and private security lighting. The utility will furnish, install, and maintain all lighting units. Metering: In lieu of metering each lamp unit, the utility will meter one or more of each size and type of lamp unit that operates for a similar time period each month. Each unit of the same size, type and on-time period shall be billed the average amount of energy as used by the metered unit(s) of the same size, type and on-time period. Pole Charges: Wood - Distribution $1.00 per lamp per month Wood- Stand Alone $3.25 per lamp per month Fiberglass $6.25 per lamp per month Steel $8.00 per lamp per month

319

Data:E0272499-c8a3-4d7c-959f-657e35319325 | Open Energy Information  

Open Energy Info (EERE)

72499-c8a3-4d7c-959f-657e35319325 72499-c8a3-4d7c-959f-657e35319325 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Barron, Wisconsin (Utility Company) Effective date: 2009/07/15 End date if known: Rate name: Ms-1 Street and Security Lighting Service: 400 W MV(Wood Pole-Stand Alone) Sector: Lighting Description: Application: This schedule will be applied to municipal street lighting and private security lighting. The utility will furnish, install, and maintain all lighting units. Metering: In lieu of metering each lamp unit, the utility will meter one or more of each size and type of lamp unit that operates for a similar time period each month. Each unit of the same size, type and on-time period shall be billed the average amount of energy as used by the metered unit(s) of the same size, type and on-time period. Pole Charges: Wood - Distribution $1.00 per lamp per month Wood- Stand Alone $3.25 per lamp per month Fiberglass $6.25 per lamp per month Steel $8.00 per lamp per month

320

Data:0831a659-fb83-4a0c-9a53-991af3e636df | Open Energy Information  

Open Energy Info (EERE)

a659-fb83-4a0c-9a53-991af3e636df a659-fb83-4a0c-9a53-991af3e636df No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Barron, Wisconsin (Utility Company) Effective date: 2009/07/15 End date if known: Rate name: Ms-1 Street and Security Lighting Service: 250 W HPS(Fiberglass) Sector: Lighting Description: Application: This schedule will be applied to municipal street lighting and private security lighting. The utility will furnish, install, and maintain all lighting units. Metering: In lieu of metering each lamp unit, the utility will meter one or more of each size and type of lamp unit that operates for a similar time period each month. Each unit of the same size, type and on-time period shall be billed the average amount of energy as used by the metered unit(s) of the same size, type and on-time period. Pole Charges: Wood - Distribution $1.00 per lamp per month Wood- Stand Alone $3.25 per lamp per month Fiberglass $6.25 per lamp per month Steel $8.00 per lamp per month

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Data:42f39f3d-bc80-422a-b5a6-8e9efa27fdb7 | Open Energy Information  

Open Energy Info (EERE)

f3d-bc80-422a-b5a6-8e9efa27fdb7 f3d-bc80-422a-b5a6-8e9efa27fdb7 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Barron, Wisconsin (Utility Company) Effective date: 2009/07/15 End date if known: Rate name: Ms-1 Street and Security Lighting Service: 100 W HPS(Fiberglass) Sector: Lighting Description: Application: This schedule will be applied to municipal street lighting and private security lighting. The utility will furnish, install, and maintain all lighting units. Metering: In lieu of metering each lamp unit, the utility will meter one or more of each size and type of lamp unit that operates for a similar time period each month. Each unit of the same size, type and on-time period shall be billed the average amount of energy as used by the metered unit(s) of the same size, type and on-time period. Pole Charges: Wood - Distribution $1.00 per lamp per month Wood- Stand Alone $3.25 per lamp per month Fiberglass $6.25 per lamp per month Steel $8.00 per lamp per month

322

New Lighting Technologies  

Science Conference Proceedings (OSTI)

This Electric Power Research Institute (EPRI) technical update continues the technical assessment of advanced lighting technologies in the following product areas—linear LED T8 fluorescent replacements, Edison-based dimmable LED lamps, commercial replacement side-lit LED fixtures, Edison-based reduced-consumption halogen lamps designed to replace 100W incandescent lamps, high bay induction LED lamps, and architectural LED lamps. Many of the products in this year’s report are designed as ...

2012-10-08T23:59:59.000Z

323

Flicker Performance of Modern Lighting Technologies including Impacts of Dimmers  

Science Conference Proceedings (OSTI)

The existing industry standards on flicker measurement and assessment are based on the response of general purpose incandescent lamps. However, worldwide these lamps are being replaced with more energy efficient lamps including Compact Fluorescent Lamps (CFLs) and Light emitting Diode (LED) lamps. In order to keep the flicker standards relevant, the industry standard bodies on the subject are in need of the evidence that compares the flicker performance of new lighting ...

2012-12-12T23:59:59.000Z

324

average air temperature | OpenEI  

Open Energy Info (EERE)

average air temperature average air temperature Dataset Summary Description (Abstract): Air Temperature at 10 m Above The Surface Of The Earth (deg C)NASA Surface meteorology and Solar Energy (SSE) Release 6.0 Data Set (Nov 2007)22-year Monthly & Annual Average (July 1983 - June 2005)Parameter: Air Temperature at 10 m Above The Surface Of The Earth (deg C)Internet: http://eosweb.larc.nasa.gov/sse/Note 1: SSE Methodology & Accuracy sections onlineNote 2: Lat/Lon values indicate the lower left corner of a 1x1 degree region. Negative values are south and west; Source U.S. National Aeronautics and Space Administration (NASA), Surface meteorology and Solar Energy (SSE) Date Released March 31st, 2009 (5 years ago) Date Updated April 01st, 2009 (5 years ago) Keywords average air temperature

325

The Shape of Averaged Drop Size Distributions  

Science Conference Proceedings (OSTI)

The shape of averaged drop size distributions (DSD) is studied from a large sample of data (892 h) collected at several sites of various latitudes. The results show that neither the hypothesis of an exponential distribution to represent rainfall ...

Henri Sauvageot; Jean-Pierre Lacaux

1995-04-01T23:59:59.000Z

326

Lagged Average Predictions in a Predictability Experiment  

Science Conference Proceedings (OSTI)

Lagged average predictions are examined here within the context of an idealized predictability experiment. Lagged predictions contribute to making better forecasts than the forecasts obtained from using only the latest initial state. Analytic ...

John O. Roads

1988-01-01T23:59:59.000Z

327

Probabilistic Visibility Forecasting Using Bayesian Model Averaging  

Science Conference Proceedings (OSTI)

Bayesian model averaging (BMA) is a statistical postprocessing technique that has been used in probabilistic weather forecasting to calibrate forecast ensembles and generate predictive probability density functions (PDFs) for weather quantities. ...

Richard M. Chmielecki; Adrian E. Raftery

2011-05-01T23:59:59.000Z

328

Average Data for Each Choke Setting (before 24-May 2010 06:00), 6-hour average (  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Average Data for Each Choke Setting (before 24-May 2010 06:00), 6-hour average (after 24-May 2010 06:00):" Average Data for Each Choke Setting (before 24-May 2010 06:00), 6-hour average (after 24-May 2010 06:00):" ,,"Choke","Average","Average","Fluid","Methanol","Water","Oil","Gas","Hyd. Eq.","Gas" ,"Choke","Setting","Upstream","Upstream","Recovery","Recovery","Recovery","Recovery","Recovery","Recovery","Recovery" "Date and Time","Setting","Duration","Pressure","Temp.","Rate","Rate","Rate","Rate","Rate","Rate","Portion" "dd-mmm-yy","(64ths)","(hours)","(psia)","(degF)","(bfpd)","(bfpd)","(bwpd)","(bopd)","(mmcfpd)","(boepd)","(%)"

329

Average transmission probability of a random stack  

E-Print Network (OSTI)

The transmission through a stack of identical slabs that are separated by gaps with random widths is usually treated by calculating the average of the logarithm of the transmission probability. We show how to calculate the average of the transmission probability itself with the aid of a recurrence relation and derive analytical upper and lower bounds. The upper bound, when used as an approximation for the transmission probability, is unreasonably good and we conjecture that it is asymptotically exact.

Yin Lu; Christian Miniatura; Berthold-Georg Englert

2009-07-31T23:59:59.000Z

330

A high average power pockels cell  

DOE Patents (OSTI)

A high average power pockels cell is disclosed which reduced the effect of thermally induced strains in high average power laser technology. The pockels cell includes an elongated, substantially rectangular crystalline structure formed from a KDP-type material to eliminate shear strains. The X- and Y-axes are oriented substantially perpendicular to the edges of the crystal cross-section and to the C-axis direction of propagation to eliminate shear strains.

Daly, T.P.

1986-02-10T23:59:59.000Z

331

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology  

SciTech Connect

The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

Not Available

1993-11-01T23:59:59.000Z

332

Estimating Averaging Times for Point and Path-Averaged Measurements of Turbulence Spectra  

Science Conference Proceedings (OSTI)

Uncertainty over how long to average turbulence variables to achieve some desired level of statistical stability is a common concern in boundary-layer meteorology. Several models exist that predict averaging times for measurements of variances ...

Edgar L. Andreas

1988-03-01T23:59:59.000Z

333

World average top-quark mass  

SciTech Connect

This paper summarizes a talk given at the Top2008 Workshop at La Biodola, Isola d Elba, Italy. The status of the world average top-quark mass is discussed. Some comments about the challanges facing the experiments in order to further improve the precision are offered.

Glenzinski, D.; /Fermilab

2008-01-01T23:59:59.000Z

334

STAFF FORECAST: AVERAGE RETAIL ELECTRICITY PRICES  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION STAFF FORECAST: AVERAGE RETAIL ELECTRICITY PRICES 2005 TO 2018 report, Staff Forecast: Retail Electricity Prices, 2005 to 2018, was prepared with contributions from the technical assistance provided by Greg Broeking of R.W. Beck, Inc. in preparing retail price forecasts

335

Exact bounds for average pairwise network reliability  

Science Conference Proceedings (OSTI)

Several methods for finding exact bounds of average pairwise network connectivity (APNC) are proposed. These methods allows faster decision making about if a network is reliable for its purpose. Previous results on cumulitive updating of all-terminal ... Keywords: algorithm, network reliability, pairwise connectivity

Alexey Rodionov; Olga Rodionova

2013-01-01T23:59:59.000Z

336

Sources Of Average Individual Radiation Exposure  

NLE Websites -- All DOE Office Websites (Extended Search)

Of Average Individual Radiation Exposure Of Average Individual Radiation Exposure Natural background Medical Consumer products Industrial, security, educational and research Occupational 0.311 rem 0.300 rem 0.013 rem 0.0003 rem 0.0005 rem Savannah River Nuclear Solutions, LLC, provides radiological protection services and oversight at the Savannah River Site (SRS). These services include radiation dose measurements for persons who enter areas where they may be exposed to radiation or radioactive material. The results are periodically reported to monitored individuals. The results listed are based on a radiation dose system developed by the International Commission on Radiation Protection. The system uses the terms "effective dose," "equivalent dose" and units of rem. You may be more familiar with the term "millirem" (mrem), which is 1/1000 of a rem.

337

Fat turnover in obese slower than average  

NLE Websites -- All DOE Office Websites (Extended Search)

9-04 9-04 For immediate release: 09/23/2011 | NR-11-09-04 Fat turnover in obese slower than average Anne M Stark, LLNL, (925) 422-9799, stark8@llnl.gov Printer-friendly This scanning electron micrograph image shows part of a lobule of adipose tissue (body fat). Adipose tissue is specialized connective tissue that functions as the major storage site for fat. Photo courtesy of David Gregory & Debbie Marshall/Wellcome Images LIVERMORE, Calif. -- It may be more difficult for obese people to lose fat because the "turnover" rate is much slower for those overweight than average weight individuals. New research in the Sept. 25 online edition of the journal Nature shows that the turnover (storage and loss rate) of fat in the human body is about 1 1/2 years compared to fat cells, which turnover about every 10 years,

338

Natural Gas Prices: Well Above Recent Averages  

Gasoline and Diesel Fuel Update (EIA)

5 5 Notes: The recent surge in spot prices at the Henry Hub are well above a typical range for 1998-1999 (in this context, defined as the average, +/- 2 standard deviations). Past price surges have been of short duration. The possibility of a downward price adjustment before the end of next winter is a source of considerable risk for storage operators who acquire gas at recent elevated prices. Storage levels in the Lower 48 States were 7.5 percent below the 5-year average (1995-1999) by mid-August (August 11), although the differential is only 6.4 percent in the East, which depends most heavily on storage to meet peak demand. Low storage levels are attributable, at least in part, to poor price incentives: high current prices combined with only small price

339

HIGH AVERAGE POWER OPTICAL FEL AMPLIFIERS.  

SciTech Connect

Historically, the first demonstration of the optical FEL was in an amplifier configuration at Stanford University [l]. There were other notable instances of amplifying a seed laser, such as the LLNL PALADIN amplifier [2] and the BNL ATF High-Gain Harmonic Generation FEL [3]. However, for the most part FELs are operated as oscillators or self amplified spontaneous emission devices. Yet, in wavelength regimes where a conventional laser seed can be used, the FEL can be used as an amplifier. One promising application is for very high average power generation, for instance FEL's with average power of 100 kW or more. The high electron beam power, high brightness and high efficiency that can be achieved with photoinjectors and superconducting Energy Recovery Linacs (ERL) combine well with the high-gain FEL amplifier to produce unprecedented average power FELs. This combination has a number of advantages. In particular, we show that for a given FEL power, an FEL amplifier can introduce lower energy spread in the beam as compared to a traditional oscillator. This properly gives the ERL based FEL amplifier a great wall-plug to optical power efficiency advantage. The optics for an amplifier is simple and compact. In addition to the general features of the high average power FEL amplifier, we will look at a 100 kW class FEL amplifier is being designed to operate on the 0.5 ampere Energy Recovery Linac which is under construction at Brookhaven National Laboratory's Collider-Accelerator Department.

BEN-ZVI, ILAN, DAYRAN, D.; LITVINENKO, V.

2005-08-21T23:59:59.000Z

340

Impact Ionization Model Using Average Energy and Average Square Energy of Distribution Function  

E-Print Network (OSTI)

Impact Ionization Model Using Average Energy and Average Square Energy of Distribution Function Ken relaxation length, v sat ø h''i (¸ 0:05¯m), the energy distribution function is not well described calculation of impact ionization coefficient requires the use of a high energy distribution function because

Dunham, Scott

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Certain Lamps Exempted from General Service Incandescent Lamp Standards Certain Lamps Exempted from General Service Incandescent Lamp Standards Sign up for e-mail updates on regulations for this and other products The information on this page pertains to the Department of Energy's (DOE) analysis of and unit sales forecast for five lamp types, which was mandated by the Energy Independence and Security Act of 2007 (EISA 2007). Among the requirements of subtitle B of title III of EISA 2007 were provisions directing DOE to evaluate and publish within 1 year a benchmark unit sales estimate for five types of incandescent lamps (rough service lamps, vibration service lamps, 3-way incandescent lamps, 2,601-3,300 lumen general service incandescent lamps, and shatter-resistant lamps). These lamp types were not made subject to the regulatory standards for general service incandescent lamps established by EISA 2007. Among the requirements of subtitle B of title III of EISA 2007 were provisions directing DOE to collect, analyze, and monitor unit sales of these five lamp types.

342

Average Price of Natural Gas Production  

Gasoline and Diesel Fuel Update (EIA)

. . Quantity and Average Price of Natural Gas Production in the United States, 1930-1996 (Volumes in Million Cubic Feet, Prices in Dollars per Thousand Cubic Feet) Table Year Gross Withdrawals Used for Repressuring Nonhydro- carbon Gases Removed Vented and Flared Marketed Production Extraction Loss Dry Production Average Wellhead Price of Marketed Production 1930 ....................... NA NA NA NA 1,978,911 75,140 1,903,771 0.08 1931 ....................... NA NA NA NA 1,721,902 62,288 1,659,614 0.07 1932 ....................... NA NA NA NA 1,593,798 51,816 1,541,982 0.06 1933 ....................... NA NA NA NA 1,596,673 48,280 1,548,393 0.06 1934 ....................... NA NA NA NA 1,815,796 52,190 1,763,606 0.06 1935 ....................... NA NA NA NA 1,968,963 55,488 1,913,475 0.06 1936 ....................... 2,691,512 73,507 NA 392,528 2,225,477

343

Average values and dispersion (in parentheses)  

NLE Websites -- All DOE Office Websites (Extended Search)

Average values and dispersion (in parentheses) Average values and dispersion (in parentheses) Base-pair Parameters --------------------------------------------------------------------------------------- Shear Stretch Stagger Buckle Propeller Opening 3DNA A 0.01(0.23) -0.18(0.10) 0.02(0.25) -0.13(7.77) -11.79(4.14) 0.57(2.80) B 0.00(0.21) -0.15(0.12) 0.09(0.19) 0.53(6.74) -11.35(5.26) 0.63(3.05) CEHS A 0.01(0.23) -0.18(0.10) 0.02(0.25) -0.13(7.75) -11.82(4.14) 0.56(2.78) B 0.00(0.21) -0.14(0.12) 0.09(0.19) 0.53(6.73) -11.37(5.27) 0.62(3.03) CompDNA A 0.01(0.23) -0.18(0.10) 0.02(0.25) -0.12(7.70) -11.81(4.14) 0.56(2.79) B 0.00(0.21) -0.15(0.12) 0.09(0.19) 0.53(6.70) -11.37(5.26) 0.62(3.03) Curves A 0.01(0.23) -0.18(0.10) 0.02(0.25) -0.13(7.85) -11.76(4.12) 0.57(2.80)

344

Locally Calibrated Probabilistic Temperature Forecasting Using Geostatistical Model Averaging and Local Bayesian Model Averaging  

Science Conference Proceedings (OSTI)

The authors introduce two ways to produce locally calibrated grid-based probabilistic forecasts of temperature. Both start from the Global Bayesian model averaging (Global BMA) statistical postprocessing method, which has constant predictive bias ...

William Kleiber; Adrian E. Raftery; Jeffrey Baars; Tilmann Gneiting; Clifford F. Mass; Eric Grimit

2011-08-01T23:59:59.000Z

345

Geographic Gossip: Efficient Averaging for Sensor Networks  

E-Print Network (OSTI)

Gossip algorithms for distributed computation are attractive due to their simplicity, distributed nature, and robustness in noisy and uncertain environments. However, using standard gossip algorithms can lead to a significant waste in energy by repeatedly recirculating redundant information. For realistic sensor network model topologies like grids and random geometric graphs, the inefficiency of gossip schemes is related to the slow mixing times of random walks on the communication graph. We propose and analyze an alternative gossiping scheme that exploits geographic information. By utilizing geographic routing combined with a simple resampling method, we demonstrate substantial gains over previously proposed gossip protocols. For regular graphs such as the ring or grid, our algorithm improves standard gossip by factors of $n$ and $\\sqrt{n}$ respectively. For the more challenging case of random geometric graphs, our algorithm computes the true average to accuracy $\\epsilon$ using $O(\\frac{n^{1.5}}{\\sqrt{\\log ...

Dimakis, Alexandros G; Wainwright, Martin J

2007-01-01T23:59:59.000Z

346

EA-1664: Final Environmental Assessment | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

64: Final Environmental Assessment 64: Final Environmental Assessment EA-1664: Final Environmental Assessment 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps The U.S. Department of Energy has determined that the adoption of energy conservation standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps as described in the final rule titled the "energy Conservation Program: Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector lamps," would not be a major federal action significantly affecting the quality of the human environment. Environmental Assessment for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps,

347

Table 5B. Commercial Average Monthly Bill by Census Division ...  

U.S. Energy Information Administration (EIA)

Home > Electricity > Electric Sales, Revenue, and Price > Commercial Average Monthly Bill by Census Division, and State: Table 5B. Commercial Average Monthly Bill by ...

348

Average summer gasoline prices expected to be slightly lower ...  

U.S. Energy Information Administration (EIA)

The retail price for regular gasoline is expected to average $3.63 per gallon during this summer driving season, slightly below average prices over ...

349

Table 5B. Commercial average monthly bill by census division...  

U.S. Energy Information Administration (EIA) Indexed Site

" Census Division " " State ","Number of Consumers "," Average Monthly Consumption (kWh)","Price (Cents per Kilowatthour)","Average Monthly Bill (Dollar and cents)" "New...

350

On the String Averaging Method for Sparse Common Fixed Points ...  

E-Print Network (OSTI)

Jul 10, 2008 ... gate a string-averaging algorithmic scheme that favorably handles the ... are special cases of the string-averaging and of the BIP algorithmic ...

351

Table 5A. Residential Average Monthly Bill by Census Division ...  

U.S. Energy Information Administration (EIA)

Table 5A. Residential Average Monthly Bill by Census Division, and State, 2009: Census Division State Number of Consumers Average Monthly Consumption ...

352

Texas Gulf Coast Refinery District API Gravity (Weighted Average ...  

U.S. Energy Information Administration (EIA)

Texas Gulf Coast Refinery District API Gravity (Weighted Average) of Crude Oil Input to Refineries (Degree)

353

Yampa Valley Electric Assn Inc | Open Energy Information  

Open Energy Info (EERE)

Yampa Valley Electric Assn Inc Yampa Valley Electric Assn Inc Place Colorado Utility Id 21081 Utility Location Yes Ownership C NERC Location WECC NERC WECC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png COMMERCIAL SERVICE Commercial IRRIGATION SERVICE Commercial LARGE POWER SERVICE Commercial OUTDOOR SECURITY LIGHTING SERVICE: 175 Watt Mercury Vapor Lamp Lighting OUTDOOR SECURITY LIGHTING SERVICE: 250 Watt Mercury Vapor Lamp Lighting OUTDOOR SECURITY LIGHTING SERVICE: 400 Watt Mercury Vapor Lamp Lighting RESIDENTIAL SERVICE Residential Average Rates Residential: $0.0960/kWh

354

New continuous-input current charge pump power-factor-correction electronic ballast  

SciTech Connect

Continuous-input current charge pump power-factor-correction (CIC-CPPFC) electronic ballasts are proposed in this paper. The CPPFC circuit and unity power factor condition using the charge pump concept are derived and analyzed. The average lamp current control with switching frequency modulation was developed so that the low crest factor and constant lamp power operation can be achieved. The developed electronic ballast has continuous input current, so that a small line input filter can be used. The proposed CIC-CPPFC electronic ballast was implemented and tested with two 45-W fluorescent lamps. It is shown that the measured line input current harmonics satisfy IEC 1000-3-2 Class C requirements.

Qian, J.; Lee, F.C. [Virginia Polytechnic Inst. and State Univ., Blacksburg, VA (United States); Yamauchi, Tokushi [Matsushita Electric Works, Ltd., Osaka (Japan). Lighting Research and Development Center

1999-03-01T23:59:59.000Z

355

Federal Energy Management Program: Energy Cost Calculator for Compact  

NLE Websites -- All DOE Office Websites (Extended Search)

Compact Fluorescent Lamps to someone by E-mail Compact Fluorescent Lamps to someone by E-mail Share Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Facebook Tweet about Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Twitter Bookmark Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Google Bookmark Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Delicious Rank Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Digg Find More places to share Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on AddThis.com... Energy-Efficient Products Federal Requirements Covered Product Categories

356

Find cost-effective investments | ENERGY STAR Buildings & Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

lamps and can save 10 per sign annually in electricity costs. Swap out incandescent light bulbs with ENERGY STAR certified CFLs or LEDs in your desk, task, and floor lamps....

357

Building Technologies Office: Solid-State Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

of two pages from the CALiPER Snapshot Report on A lamps. CALiPER Product Snapshot on LED Light Bulbs Report on the current state of the market for LED A lamp and omnidirectional...

358

Commercialization-Analysis-&-Roadmap-  

indicated!in!note!13!is!$232.!!Total!energy!cost!=!$2000.!We!used!the!$19!cost!for!30W!germicidal! lamps!from!asltg.com,!although!lamps!were!36!W.!! [17] ...

359

Building Technologies Program - 1995 Annual Report  

E-Print Network (OSTI)

CFL fixture achieves the highest fixture efficiency byCFL, and a 22-watt Circline™ fluorescent lamp, with fixture efficienciesCFL rather than the typical A-Lamp have the possibility of significantly in- creasing fixture efficiency

Selkowitz, S.E.

2010-01-01T23:59:59.000Z

360

Energy Efficiency Standards and Labels in North America: Opportunities for Harmonization  

E-Print Network (OSTI)

L mc ,S m L ve ** ,S m Dishwashers L mc ,L ve ,S m L mc ,LClothes washers Clothes washers and dryers DishwashersDishwashers Fluorescent lamp ballasts Fluorescent lamp

Wiel, Stephen

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Solid-State Lighting on a Shoestring Budget: The Economics of Off-Grid Lighting for Small Businesses in Kenya  

E-Print Network (OSTI)

to Charge a 1200 mAh Battery Cost per LED Lamp Charge (Ksh/battery powered LED lamps introduced to the businesses and the costbattery charging services, while solar charging did not involve any ongoing costs.

Radecsky, Kristen

2009-01-01T23:59:59.000Z

362

Energy Basics: Fluorescent Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Fluorescent Lighting Fluorescent lamps use 25%-35% of the energy used by incandescent lamps to provide the same amount of illumination (efficacy of 30-110 lumens per watt). They...

363

Solid-State Lighting: LED Replacements for Linear Fluorescent...  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Replacements for Linear Fluorescent Lamps Webcast to someone by E-mail Share Solid-State Lighting: LED Replacements for Linear Fluorescent Lamps Webcast on Facebook Tweet about...

364

LBNL-5364E  

NLE Websites -- All DOE Office Websites (Extended Search)

as do HID lamps, and an LED lamp includes electronic driver and optics) LED light-emitting diode ix lumen a measure of the power of light perceived by the human eye microgrid A...

365

DOE Solar Decathlon: 2009 Building Industry Workshops  

NLE Websites -- All DOE Office Websites (Extended Search)

workshop addresses an array of energy-efficient lighting options, focusing on light-emitting diode (LED) lamps and compact fluorescent lamps. (PDF 3.7 MB) LEED for Homes: Green...

366

PHASE I FINAL REPORT SUBCONTRACT NO. 2019702 "ENERGY EFFICIENT FLUORESCENT BALLASTS"  

E-Print Network (OSTI)

Stabilize ballast at 235 volts input AC for 60 seconds withI Sec. (Lamp) E Cathode Ckt Volt: Yel Dum. Load Full. L.O.Factor Same lamps used = Watts/Volt-Amps, Approx. accuracy +

Authors, Various

2011-01-01T23:59:59.000Z

367

Illuminated Diagrams: Using Light and Print to Comparative Advantage W. Bradford Paley  

E-Print Network (OSTI)

the representation of information. Raskar's "Shader Lamps," e.g. [4] project onto dioramas to add textures; G. Welch, K-L Low, D. Bandyopadhyay, "Shader Lamps: Animating Real Objects with Image Based

Indiana University

368

May 1999 POV-Ray 3.1g User Documentation Page 1 Persistence of Vision TM Ray-Tracer  

E-Print Network (OSTI)

existing wall and desk surfaces to expand the area of the traditional computer interface. With Shader Lamps. Bandyopadhyay, "Shader lamps: Animating real objects with image-based illumination," in Rendering Techniques

Sherrill, David

369

In Support of Leadership: Robitaille  

E-Print Network (OSTI)

2004), pages 165­172, June 2004. 2 [2] D. Bandyopadhyay, R. Raskar, and H. Fuchs. Dynamic shader lamps. Bandyopadhyay. Shader lamps: Animating real objects with image-based illu- mination. In Rendering Techniques

de Lijser, Peter

370

Journal of Biopharmaceutical Statistics, 19: 641657, 2009 Copyright Taylor & Francis Group, LLC  

E-Print Network (OSTI)

existing wall and desk surfaces to expand the area of the traditional computer interface. With Shader Lamps. Bandyopadhyay, "Shader lamps: Animating real objects with image-based illumination," in Rendering Techniques

Qin, Zhaohui Steve

371

Baltimore Gas & Electric Company (Electric) - Commercial Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lamps: 25 - 30 Lighting Occupancy Sensors: 25-75unit T8T5 Fluorescent Lamp-Ballast: 15-65fixture Fluorescent High-Bay Fixtures: 40 - 85fixture Hard-Wired CFL:...

372

Fluorescent fixtures and ballasts  

SciTech Connect

The basic parameters of a fluorescent lighting system that affect the illumination level are discussed. The parameters include the thermal performance of the fixture and the ballast factor, voltage regulation, and thermal regulation of the ballast/lamp system. Fixtures determine the minimum lamp-wall temperature of the lamps and are described as hot or cold. That is, the lamp-wall temperatures can vary from 39 to 61/sup 0/C. In general, cool fixtures tend to provide higher light levels and are more efficacious for a given ballast/lamp system. Solid-state fluorescent ballast/lamp systems have been measured and show a variation in light output from 6170 to 3780 lumens for the two-lamp, F-40, T-12, rapid-start lamps. Lighting designers must obtain this information in order to accurately predict illumination levels in a space.

Verderber, R.R.

1984-05-01T23:59:59.000Z

373

Browse wiki | Open Energy Information  

Open Energy Info (EERE)

dusk till daylight. Price of lamp per month: (Rated kW capacity of lamp, including ballast x 4000 x 0.0741)12p, including ballast x 4000 x 0.0741)12 OpenEIUtilityRate...

374

Section 5.4.3 Compact Fluorescent Lighting: Greening Federal...  

NLE Websites -- All DOE Office Websites (Extended Search)

2.7 m), wall-wash- ers, and decorative pendants. Retrofit lamps that contain the lamp, ballast, and screw base all in one unit are widely available. As a rule, however, these units...

375

RoHS  

Science Conference Proceedings (OSTI)

... Cat 4. Consumer electronics: TVs, DVD players, stereos, video cameras; Cat 5. Lighting: lamps, lighting fixtures, light bulbs; ...

376

No Slide Title  

Science Conference Proceedings (OSTI)

... 85 Customers, 400 Lamps George Westinghouse and Nikola Tesla Thomas Edison and Joseph Swan Power Distribution Options -- Battle ...

2012-07-24T23:59:59.000Z

377

Energy Efficiency Indicators Methodology Booklet  

E-Print Network (OSTI)

Kerosene lamp Wood Stove Biogas Stove Charcoal Stove CoalDistrict heating Wood Biogas Charcoal Stove/ Room Coal

Sathaye, Jayant

2010-01-01T23:59:59.000Z

378

After-hours power status of office equipment and energy use of miscellaneous plug-load equipment  

E-Print Network (OSTI)

industrial refrigerator, S freezer incandescent tracklight, 50 lamps each phone/PBX centrex system coffee maker, residential model microwave oven

Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Margaret; Busch, John F.

2004-01-01T23:59:59.000Z

379

NIST Highlight about spectrally tunable lighting facility  

Science Conference Proceedings (OSTI)

... white light produced by fluorescent lamps? Which spectral combination gives the best color quality and energy efficiency? ...

2012-10-02T23:59:59.000Z

380

(SAN DIEGO ASSOCIATION OF GOVERNMENTS)  

E-Print Network (OSTI)

, or Light Emitting Diode. The lamps were also classified by location in the house, wattage, hardwired vs

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

OE Summary 2005-14  

NLE Websites -- All DOE Office Websites (Extended Search)

power lines ...1 * Improper modification results in electric arc that shatters lamp lens ... 6 * Good Practice: Use of safety belt...

382

UNDERWRITERS' LABORATORIES, INC.  

Science Conference Proceedings (OSTI)

... Key Words - Arrhenius Law, Light Emitting Diode, Light Degradation Rate, Photoelectric ... Light Emitting DiOde (LED) Source Lamps (2) ...

2009-05-05T23:59:59.000Z

383

Advanced Lighting Technologies  

Science Conference Proceedings (OSTI)

This report continues the technical assessment of advanced lighting technologies in the following product areasdimmable light-emitting diode (LED) screw-in replacement lamp, hybrid compact fluorescent lamp/halogen screw-in replacement lamp, replacement recessed can LED downlight, organic LED (OLED) disc, replacement mini high-intensity discharge (HID) lamp and ballast system, and solid-state plasma lighting (miniature HID technology) high-bay fixture. The research in this project helps to demonstrate how...

2011-12-21T23:59:59.000Z

385

Characteristics and Applications of Copper Stamp Sand  

Science Conference Proceedings (OSTI)

The chemical, physical properties and antimicrobial activity of stamp sand were investigated, ... Characterization of Fluorescent Lamp Glass Waste Powders for ...

386

Vehicle Technologies Office: Fact #328: July 12, 2004 Expected Average  

NLE Websites -- All DOE Office Websites (Extended Search)

8: July 12, 2004 8: July 12, 2004 Expected Average Annual Miles to someone by E-mail Share Vehicle Technologies Office: Fact #328: July 12, 2004 Expected Average Annual Miles on Facebook Tweet about Vehicle Technologies Office: Fact #328: July 12, 2004 Expected Average Annual Miles on Twitter Bookmark Vehicle Technologies Office: Fact #328: July 12, 2004 Expected Average Annual Miles on Google Bookmark Vehicle Technologies Office: Fact #328: July 12, 2004 Expected Average Annual Miles on Delicious Rank Vehicle Technologies Office: Fact #328: July 12, 2004 Expected Average Annual Miles on Digg Find More places to share Vehicle Technologies Office: Fact #328: July 12, 2004 Expected Average Annual Miles on AddThis.com... Fact #328: July 12, 2004 Expected Average Annual Miles Twenty-five percent of the respondents to a nationwide survey said that

387

Vehicle Technologies Office: Fact #87: May 4, 1999 Average Annual...  

NLE Websites -- All DOE Office Websites (Extended Search)

7: May 4, 1999 Average Annual Miles per Vehicle by Vehicle Type and Age to someone by E-mail Share Vehicle Technologies Office: Fact 87: May 4, 1999 Average Annual Miles per...

388

Vehicle Technologies Office: Fact #536: September 15, 2008 Average...  

NLE Websites -- All DOE Office Websites (Extended Search)

6: September 15, 2008 Average Used Car Prices Up and Used Light Truck Prices Down to someone by E-mail Share Vehicle Technologies Office: Fact 536: September 15, 2008 Average Used...

389

Vehicle Technologies Office: Fact #517: May 5, 2008 State Average...  

NLE Websites -- All DOE Office Websites (Extended Search)

7: May 5, 2008 State Average Gasoline Prices, April 18, 2008 to someone by E-mail Share Vehicle Technologies Office: Fact 517: May 5, 2008 State Average Gasoline Prices, April 18,...

390

Vehicle Technologies Office: Fact #744: September 10, 2012 Average...  

NLE Websites -- All DOE Office Websites (Extended Search)

4: September 10, 2012 Average New Light Vehicle Price Grows Faster than Average Used Light Vehicle Price to someone by E-mail Share Vehicle Technologies Office: Fact 744:...

391

Improving Wind Profiler–Measured Winds Using Coplanar Spectral Averaging  

Science Conference Proceedings (OSTI)

A method is presented that increases the detectability of weak clear-air signals by averaging Doppler spectra from coplanar wind profiler beams. The method, called coplanar spectral averaging (CSA), is applied to both simulated wind profiler ...

Robert Schafer; Susan K. Avery; Kenneth S. Gage; Paul E. Johnston; D. A. Carter

2004-11-01T23:59:59.000Z

392

On Lateral Dispersion Coefficients as Functions of Averaging Time  

Science Conference Proceedings (OSTI)

Plume dispersion coefficients are discussed in terms of single-particle and relative diffusion, and are investigated as functions of averaging time. To demonstrate the effects of averaging time on the relative importance of various dispersion ...

C. M. Sheih

1980-05-01T23:59:59.000Z

393

Vorticity Dynamics and Zonally Averaged Ocean Circulation Models  

Science Conference Proceedings (OSTI)

Diagnostic equations relating the zonally averaged overturning circulation to north–south density variations are derived and used to determine a new closure scheme for use in zonally averaged ocean models. The presentation clarifies the dynamical ...

Daniel G. Wright; Cornelis B. Vreugdenhil; Tertia M. C. Hughes

1995-09-01T23:59:59.000Z

394

Probabilistic Quantitative Precipitation Forecasting Using Bayesian Model Averaging  

Science Conference Proceedings (OSTI)

Bayesian model averaging (BMA) is a statistical way of postprocessing forecast ensembles to create predictive probability density functions (PDFs) for weather quantities. It represents the predictive PDF as a weighted average of PDFs centered on ...

J. Mc Lean Sloughter; Adrian E. Raftery; Tilmann Gneiting; Chris Fraley

2007-09-01T23:59:59.000Z

395

Table 5C. Industrial Average Monthly Bill by Census Division ...  

U.S. Energy Information Administration (EIA)

Home > Electricity > Electric Sales, Revenue, and Price > Industrial Average Monthly Bill by Census Division, and State: Table 5C. Industrial ...

396

Table 4. Average retail price for bundled and unbundled consumers ...  

U.S. Energy Information Administration (EIA)

Table 4. Average retail price for bundled and unbundled consumers by sector, Census Division, and State 2011

397

Maryland Average Price of Natural Gas Delivered to Residential and ...  

U.S. Energy Information Administration (EIA)

Average Price of Natural Gas Delivered to Residential and Commercial Consumers by Local Distribution and Marketers in Selected States

398

Optimization Online - "Block-Iterative and String-Averaging ...  

E-Print Network (OSTI)

Jul 19, 2009 ... Optimization Online. "Block-Iterative and String-Averaging Projection Algorithms in Proton Computed Tomography Image Reconstruction".

399

Undergraduate Handbook 1UNDERGRADUATE HANDBOOK 2013  

E-Print Network (OSTI)

. 1.12. The high-pressure arc lamp studied with x-ray-induced fluorescence consists of a ceramic. The gas under arc- discharge is contained in jackets of ceramic alumina and pyrex, amounting to many. 1.13. X-ray-induced fluorescence spectrum of a 150 W ceramic metal-halide lamp with the lamp off

Waikato, University of

400

Molecular Physics, Vol. 104, Nos. 57, 10 March10 April 2006, 943955 Excited state intramolecular proton transfer  

E-Print Network (OSTI)

in the section "How are LCD Panels Driven?". FIGURE 9: CONTRAST vs. RMS VOLTAGE 100% 90% 10% VOFF VTH VON VRMS of surface on the back of the display requires 2 to 3 watts. FIGURE 10: RESPONSE vs.TEMPERATURE 300 Time LCD panels, such as, incandescent lamps, LEDs, and electrolumi- nescent lamps. Incandescent lamps

Minnesota, University of

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Hurdling barriers through market uncertainty: Case studies in innovative technology adoption  

E-Print Network (OSTI)

4.5-watt LED lamps replacing the incandescent bulbs. The LEDwatt incandescent bulbs to 4.5 watt LEDs will save 55 kW xLED lamps were compatible with the existing framework of lamp operation – they could be used in the same way the incandescent bulbs

Payne, Christopher T.; Radspieler Jr., Anthony; Payne, Jack

2002-01-01T23:59:59.000Z

402

Self-reported Impacts of LED Lighting Technology Compared to Fuel-based Lighting on Night Market Business Prosperity in Kenya  

E-Print Network (OSTI)

s kiosk illuminated by her LED lamp [1/2009] “A.N. ” Market:25 Ksh/night) and Post 07/2008 LED-NiMH lamp (4 Ksh/night) (to charge at a shop) “The [LED] lamp is very important and

Johnstone, Peter

2009-01-01T23:59:59.000Z

403

Vehicle Technologies Office: Fact #310: March 8, 2004 Average Material  

NLE Websites -- All DOE Office Websites (Extended Search)

0: March 8, 2004 0: March 8, 2004 Average Material Consumption for a Domestic Automobile to someone by E-mail Share Vehicle Technologies Office: Fact #310: March 8, 2004 Average Material Consumption for a Domestic Automobile on Facebook Tweet about Vehicle Technologies Office: Fact #310: March 8, 2004 Average Material Consumption for a Domestic Automobile on Twitter Bookmark Vehicle Technologies Office: Fact #310: March 8, 2004 Average Material Consumption for a Domestic Automobile on Google Bookmark Vehicle Technologies Office: Fact #310: March 8, 2004 Average Material Consumption for a Domestic Automobile on Delicious Rank Vehicle Technologies Office: Fact #310: March 8, 2004 Average Material Consumption for a Domestic Automobile on Digg Find More places to share Vehicle Technologies Office: Fact #310:

404

Average Interest Rate for Treasury Securities | Data.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Average Interest Rate for Treasury Securities Average Interest Rate for Treasury Securities Consumer Data Apps Challenges Resources About Blogs Let's Talk Feedback Consumer You are here Data.gov » Communities » Consumer » Data Average Interest Rate for Treasury Securities Dataset Summary Description This dataset shows the average interest rates for U.S Treasury securities for the most recent month compared with the same month of the previous year. The data is broken down by the various marketable and non-marketable securities. The summary page for the data provides links for monthly reports from 2001 through the current year. Average Interest Rates are calculated on the total unmatured interest-bearing debt. The average interest rates for total marketable, total non-marketable and total interest-bearing debt do not include the U.S. Treasury Inflation-Protected Securities.

405

Orbit-averaged guiding-center Fokker-Planck operator  

Science Conference Proceedings (OSTI)

A general orbit-averaged guiding-center Fokker-Planck operator suitable for the numerical analysis of transport processes in axisymmetric magnetized plasmas is presented. The orbit-averaged guiding-center operator describes transport processes in a three-dimensional guiding-center invariant space: the orbit-averaged magnetic-flux invariant {psi}, the minimum-B pitch-angle coordinate {xi}{sub 0}, and the momentum magnitude p.

Brizard, A. J. [Department of Chemistry and Physics, Saint Michael's College, Colchester, Vermont 05439 (United States); Decker, J.; Peysson, Y.; Duthoit, F.-X. [CEA, IRFM, Saint-Paul-lez-Durance F-13108 (France)

2009-10-15T23:59:59.000Z

406

,"Selected National Average Natural Gas Prices"  

U.S. Energy Information Administration (EIA) Indexed Site

Selected National Average Natural Gas Prices" Selected National Average Natural Gas Prices" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","Average Natural Gas Prices",11,"Monthly","11/2013","1/15/1973" ,"Data 2","Annual Average Natural Gas Prices",11,"Annual",2012,"6/30/1922" ,"Release Date:","12/12/2013" ,"Next Release Date:","1/7/2014" ,"Excel File Name:","ngm03vmall.xls" ,"Available from Web Page:","http://www.eia.gov/oil_gas/natural_gas/data_publications/natural_gas_monthly/ngm.html"

407

Average Depth of Crude Oil and Natural Gas Wells  

U.S. Energy Information Administration (EIA)

-No Data Reported; --= Not Applicable; NA = Not Available; W = Withheld to avoid disclosure of individual company data. Notes: Average depth may ...

408

New York Average Price of Natural Gas Delivered to Residential ...  

U.S. Energy Information Administration (EIA)

Average Price of Natural Gas Delivered to Residential and Commercial Consumers by Local Distribution and Marketers in Selected States (Dollars per ...

409

Ohio Average Price of Natural Gas Delivered to Residential and ...  

U.S. Energy Information Administration (EIA)

Average Price of Natural Gas Delivered to Residential and Commercial Consumers by Local Distribution and Marketers in Selected States (Dollars per Thousand Cubic Feet ...

410

Average prices for spot sulfur dioxide emissions allowances at ...  

U.S. Energy Information Administration (EIA)

The weighted average spot price for sulfur dioxide (SO 2) emissions allowances awarded to winning bidders at Environmental Protection Agency's (EPA) annual auction on ...

411

Electric Sales, Revenue, and Average Price 2011 - Energy Information...  

U.S. Energy Information Administration (EIA) Indexed Site

All Electricity Reports Electric Sales, Revenue, and Average Price With Data for 2011 | Release Date: September 27, 2012 | Next Release Date: September, 2013 Previous editions...

412

Chapter 5. Retail Sales, Revenue, and Average Retail Price of ...  

U.S. Energy Information Administration (EIA)

106 U.S. Energy Information Administration/Electric Power Monthly June 2012 Chapter 5. Retail Sales, Revenue, and Average Retail Price of Electricity

413

Table 14a. Average Electricity Prices, Projected vs. Actual  

U.S. Energy Information Administration (EIA) Indexed Site

a. Average Electricity Prices, Projected vs. Actual" "Projected Price in Constant Dollars" " (constant dollars, cents per kilowatt-hour in ""dollar year"" specific to each AEO)"...

414

Average wholesale electric power prices rose in 2010 - Today in ...  

U.S. Energy Information Administration (EIA)

Average wholesale electric power prices rose in 2010, due to higher national natural gas prices and increased demand for electricity, particularly in the Eastern ...

415

Electric Sales, Revenue, and Average Price 2011 - Energy ...  

U.S. Energy Information Administration (EIA)

Class of Ownership, Number of Consumers, Sales, Revenue, and Average Retail Price for Power Marketers and Energy Service Providers by State: T12:

416

Today in Energy - Average wholesale natural gas prices mostly ...  

U.S. Energy Information Administration (EIA)

Average spot natural gas prices, which reflect the wholesale price of natural gas at major trading points, generally declined in most U.S. regional markets about 7% ...

417

,"U.S. Natural Gas Average Annual Consumption per Commercial...  

U.S. Energy Information Administration (EIA) Indexed Site

,"Worksheet Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","U.S. Natural Gas Average Annual Consumption per Commercial Consumer (Mcf)",1,"Annual",2011...

418

,"U.S. Natural Gas Average Annual Consumption per Industrial...  

U.S. Energy Information Administration (EIA) Indexed Site

,"Worksheet Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","U.S. Natural Gas Average Annual Consumption per Industrial Consumer (Mcf)",1,"Annual",2011...

419

2012 Brief: Average wholesale electricity prices down compared ...  

U.S. Energy Information Administration (EIA)

2012 Brief: Average wholesale electricity prices down compared to last year. ... wholesale electric power prices often trend together with natural gas prices.

420

Table AP7. Average Expenditures for Home Appliances and Lighting ...  

U.S. Energy Information Administration (EIA)

A household is assigned to a climate zone according to the 30-year average annual degree-days for an appropriate nearby weather station.

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Figure 34. Ratio of average per megawatthour fuel costs ...  

U.S. Energy Information Administration (EIA)

Title: Figure 34. Ratio of average per megawatthour fuel costs for natural gas combined-cycle plants to coal-fired steam turbines in the RFC west ...

422

Average wholesale spot natural gas prices rose across the country ...  

U.S. Energy Information Administration (EIA)

Wholesale spot natural gas prices rose across the country in 2010. Average spot natural gas prices at the Henry Hub—a key benchmark location for pricing throughout ...

423

EIA Renewable Energy- Average Energy Conversion Efficiency of ...  

U.S. Energy Information Administration (EIA)

Renewables and Alternate Fuels > Solar Photovoltaic Cell/Module Annual Report > Annual Shipments of Photovoltaic Cells and Modules by Source: Average Energy ...

424

Solar: monthly and annual average global horizontal (GHI) GIS...  

Open Energy Info (EERE)

on cloud cover, atmospheric water vapor and trace gases, and the amount of aerosols in the atmosphere to calculate the monthly average daily total insolation (sun and...

425

Solar: monthly and annual average direct normal (DNI), global...  

Open Energy Info (EERE)

on cloud cover, atmospheric water vapor and trace gases, and the amount of aerosols in the atmosphere to calculate the monthly average daily total insolation (sun and...

426

Solar: monthly and annual average direct normal (DNI) GIS data...  

Open Energy Info (EERE)

on cloud cover, atmospheric water vapor and trace gases, and the amount of aerosols in the atmosphere to calculate the monthly average daily total insolation (sun and...

427

Climate: monthly and annual average relative humidity GIS data...  

Open Energy Info (EERE)

Climate: monthly and annual average relative humidity GIS data at one-degree resolution of the World from NASASSE

(Abstract):  
Relative Humidity at 10 m...

428

Pennsylvania Average Price of Natural Gas Delivered to Residential ...  

U.S. Energy Information Administration (EIA)

Average Price of Natural Gas Delivered to Residential and Commercial Consumers by Local Distribution and Marketers in Selected States (Dollars per Thousand Cubic Feet ...

429

District of Columbia Average Price of Natural Gas Delivered to ...  

U.S. Energy Information Administration (EIA)

Average Price of Natural Gas Delivered to Residential and Commercial Consumers by Local Distribution and Marketers in Selected States (Dollars per Thousand Cubic Feet ...

430

Michigan Average Price of Natural Gas Delivered to Residential and ...  

U.S. Energy Information Administration (EIA)

Average Price of Natural Gas Delivered to Residential and Commercial Consumers by Local Distribution and Marketers in Selected States (Dollars per Thousand Cubic Feet ...

431

Environmental impacts of lighting technologies - Life cycle assessment and sensitivity analysis  

SciTech Connect

With two regulations, 244/2009 and 245/2009, the European Commission recently put into practice the EuP Directive in the area of lighting devices, aiming to improve energy efficiency in the domestic lighting sector. This article presents a comprehensive life cycle assessment comparison of four different lighting technologies: the tungsten lamp, the halogen lamp, the conventional fluorescent lamp and the compact fluorescent lamp. Taking advantage of the most up-to-date life cycle inventory database available (ecoinvent data version 2.01), all life cycle phases were assessed and the sensitivity of the results for varying assumptions analysed: different qualities of compact fluorescent lamps (production phase), different electricity mixes (use phase), and end-of-life scenarios for WEEE recycling versus municipal solid waste incineration (disposal phase). A functional unit of 'one hour of lighting' was defined and the environmental burdens for the whole life cycle for all four lamp types were calculated, showing a clearly lower impact for the two gas-discharge lamps, i.e. the fluorescent and the compact fluorescent lamp. Differences in the product quality of the compact fluorescent lamps reveal to have only a very small effect on the overall environmental performance of this lamp type; a decline of the actual life time of this lamp type doesn't result in a change of the rank order of the results of the here examined four lamp types. It was also shown that the environmental break-even point of the gas-discharge lamps is reached long before the end of their expected life-span. All in all, it can be concluded that a change from today's tungsten lamp technology to a low-energy-consuming technology such as the compact fluorescent lamp results in a substantial environmental benefit.

Welz, Tobias; Hischier, Roland, E-mail: Roland.Hischier@empa.ch; Hilty, Lorenz M.

2011-04-15T23:59:59.000Z

432

Variation in Nimbus-7 Cloud Estimates. Part I: Zonal Averages  

Science Conference Proceedings (OSTI)

Zonal averages of low, middle and total cloud amount estimates derived from measurements from Nimbus-7 have been analyzed for the six-year period April 1979 through March 1985. The globally and zonally averaged values of six-year annual means and ...

Bryan C. Weare

1992-12-01T23:59:59.000Z

433

Solar: monthly and annual average direct normal (DNI), global horizontal  

Open Energy Info (EERE)

East Asia from NREL East Asia from NREL Dataset Summary Description (Abstract): Monthly Average Solar Resource for horizontal and tilted flat-plates, and 2-axis tracking concentrating collectors. (Purpose): Provide information on the solar resource potential for the data domain. The insolation values represent the average solar energy available to solar collectors. (Supplemental Information): These data provide monthly average and annual average daily total solar resource averaged over surface cells of approximately 40 km by 40 km in size. The solar resource value is represented as watt-hours per square meter per day for each month. The data were developed from NREL's Climatological Solar Radiation (CSR) Model. This model uses information on cloud cover, atmospheric water

434

Solar: monthly and annual average direct normal (DNI), global horizontal  

Open Energy Info (EERE)

Africa from NREL Africa from NREL Dataset Summary Description (Abstract): Monthly Average Solar Resource for horizontal and tilted flat-plates, and 2-axis tracking concentrating collectors. (Purpose): Provide information on the solar resource potential for the data domain. The insolation values represent the average solar energy available to solar collectors. (Supplemental Information): These data provide monthly average and annual average daily total solar resource averaged over surface cells of approximately 40 km by 40 km in size. The solar resource value is represented as watt-hours per square meter per day for each month. The data were developed from NREL's Climatological Solar Radiation (CSR) Model. This model uses information on cloud cover, atmospheric water

435

EA-1664: Finding of No Significant Impact | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4: Finding of No Significant Impact 4: Finding of No Significant Impact EA-1664: Finding of No Significant Impact Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps The U.S. Department of Energy has determined that the adoption of energy conservation standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps as described in the final rule titled the "energy Conservation Program: Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector lamps," would not be a major federal action significantly affecting the quality of the human environment. Finding of No Significant Impact for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent

436

History and technical evolution of high frequency fluorescent lighting  

SciTech Connect

This work was performed to accelerate development and commercialization of solid-state, high frequency ballasts for fluorescent lighting systems. The history and development of fluorescent lamps, of ballasts for these fixtures, and of related circuits and equipment are reviewed. The higher lamp efficiency of high-frequency (300 to 3000 Hz) fluorescent lamps as compared with 60 Hz lamps, the development of frequency converter circuits for high-frequency lamps, and uses, electrical characteristics, and economics of these lighting systems are discussed. (LCL)

Campbell, J.H.

1977-12-01T23:59:59.000Z

437

Long-run marginal costs lower than average costs  

SciTech Connect

The thesis of this article is that the long-run marginal costs of electricity are not always greater than the present average costs, as is often assumed. As long as short-run costs decrease with new plant additions, the long-run marginal cost is less than long-run average cost. When average costs increase with new additions, long-run marginal costs are greater than long-run average costs. The long-run marginal costs of a particular utility may be less than, equal to, or greater than its long-run average costs - even with inflation present. The way to determine which condition holds for a given utility is to estimate costs under various combinations of assumptions: probable load growth, zero load growth, and load growth greater than expected; and changes in load factor with attendant costs. Utilities that can demonstrate long-run marginal costs lower than long-run average costs should be encouraged to build plant and increase load, for the resulting productivity gains and slowing of inflation. Utilities that face long-run marginal costs greater than long-run average costs should discourage growth in sales through any available means.

Hunter, S.R.

1980-01-03T23:59:59.000Z

438

annual average heating degree days | OpenEI  

Open Energy Info (EERE)

average heating degree days average heating degree days Dataset Summary Description (Abstract): Heating Degree Days below 18° C (degree days)The monthly accumulation of degrees when the daily mean temperature is below 18° C.NASA Surface meteorology and Solar Energy (SSE) Release 6.0 Data Set (Nov 2007)22-year Monthly Average & Annual Sum (July 1983 - June 2005)Parameter: Heating Degree Days Below 18 degrees C (degree days)Internet: http://eosweb.larc.nasa.gov/sse/ Source U.S. National Aeronautics and Space Administration (NASA), Surface meteorology and Solar Energy (SSE) Date Released March 31st, 2009 (5 years ago) Date Updated April 01st, 2009 (5 years ago) Keywords annual average heating degree days climate GIS NASA SWERA UNEP Data application/zip icon Download Shapefile (zip, 2.7 MiB)

439

Figure 33. Ratio of average per megawatthour fuel costs for ...  

U.S. Energy Information Administration (EIA)

Sheet3 Sheet2 Sheet1 Figure 33. Ratio of average per megawatthour fuel costs for natural gas combined-cycle plants to coal-fired steam turbines in the SERC southeast ...

440

Figure 27. Ratio of average per megawatthour fuel costs for ...  

U.S. Energy Information Administration (EIA)

Sheet3 Sheet2 Sheet1 Figure 27. Ratio of average per megawatthour fuel costs for natural gas combined-cycle plants to coal-fired steam turbines in five cases, 2008-2040

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

ARM - Evaluation Product - Average of Cloud Condensation Nuclei...  

NLE Websites -- All DOE Office Websites (Extended Search)

are averaged together. The %ss in the CCN data stream is calculated using a heat transfer and fluid dynamics model flow model (Lance et al., 2006). The model uses the...

442

Virginia Average Price of Natural Gas Delivered to Residential...  

U.S. Energy Information Administration (EIA) Indexed Site

10.34 9.79 11.62 14.97 NA 20.70 1989-2013 Commercial Average Price 8.35 8.21 9.11 9.52 9.96 10.36...

443

New York Average Price of Natural Gas Delivered to Residential...  

U.S. Energy Information Administration (EIA) Indexed Site

94 11.57 12.82 15.94 18.40 18.73 1989-2013 Commercial Average Price 8.38 8.32 8.27 8.38 7.91 6.66...

444

Maryland Average Price of Natural Gas Delivered to Residential...  

U.S. Energy Information Administration (EIA) Indexed Site

0.35 10.04 12.02 15.43 17.45 16.48 1989-2013 Commercial Average Price 9.03 9.30 10.67 11.84 12.79 NA...

445

Figure 88. Annual average Henry Hub spot prices for natural ...  

U.S. Energy Information Administration (EIA)

Sheet3 Sheet2 Sheet1 Figure 88. Annual average Henry Hub spot prices for natural gas in five cases, 1990-2040 (2011 dollars per million Btu) Reference

446

Figure 86. Annual average Henry Hub spot natural gas prices ...  

U.S. Energy Information Administration (EIA)

Sheet3 Sheet2 Sheet1 Figure 86. Annual average Henry Hub spot natural gas prices, 1990-2040 (2011 dollars per million Btu) Henry Hub Spot Price 1990.00

447

Table 14b. Average Electricity Prices, Projected vs. Actual  

Gasoline and Diesel Fuel Update (EIA)

b. Average Electricity Prices, Projected vs. Actual Projected Price in Nominal Dollars (nominal dollars, cents per kilowatt-hour) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002...

448

2012 Brief: Average wholesale electricity prices down compared to ...  

U.S. Energy Information Administration (EIA)

Average, on-peak (weekdays from 7:00 a.m. to 11:00 p.m.) day-ahead electricity prices were lower across the entire United States in 2012 compared to 2011.

449

Table 14b. Average Electricity Prices, Projected vs. Actual  

U.S. Energy Information Administration (EIA) Indexed Site

b. Average Electricity Prices, Projected vs. Actual" "Projected Price in Nominal Dollars" " (nominal dollars, cents per kilowatt-hour)" ,1993,1994,1995,1996,1997,1998,1999,2000,200...

450

Does anyone have access to 2012 average residential rates by...  

Open Energy Info (EERE)

Does anyone have access to 2012 average residential rates by utility company? I'm seeing an inconsistency between the OpenEI website and EIA 861 data set. Home > Groups > Utility...

451

Exact Averaging of Atmospheric State and Flow Variables  

Science Conference Proceedings (OSTI)

A new set of averaging rules is put forward that exactly determines the means of air temperature, mixing ratio, and velocity by incorporating weighting factors in accordance with physical conservation laws. For the temperature and velocity, ...

Andrew S. Kowalski

2012-05-01T23:59:59.000Z

452

Electric Sales, Revenue, and Average Price 2011 - Energy ...  

U.S. Energy Information Administration (EIA)

2001-2010 are Excel zipped files & 1994-2000 are PDF files ... and Average Retail Price for Power Marketers and ... U.S. Department of Energy USA.gov FedStats.

453

U.S. Natural Gas Average Consumption per Commercial Consumer...  

U.S. Energy Information Administration (EIA) Indexed Site

Commercial Consumer (Thousand Cubic Feet) U.S. Natural Gas Average Consumption per Commercial Consumer (Thousand Cubic Feet) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5 Year-6...

454

Average Diurnal Variation of Summer Lightning over the Floirida Peninsula  

Science Conference Proceedings (OSTI)

Data derived from a large network of electric field mills have been used to determine the average diurnal variation of lightning in a Florida seacoast environment. These data were obtained at the NASA Kennedy Space Center (KSC) and the Cape ...

Launa M. Maier; E. Philip Krider; Michael W. Maier

1984-06-01T23:59:59.000Z

455

Benthic Boundary-Layer Velocity Profiles: Dependence on Averaging Period  

Science Conference Proceedings (OSTI)

The relationship between benthic boundary-layer velocity profiles and current meter averaging time is investigated using detailed (0.61 Hz) current measurements recorded within 1 m of the bottom on the inner continental shelf. The percentage of ...

Barry M. Lesht

1980-06-01T23:59:59.000Z

456

Solar: monthly and annual average global horizontal irradiance...  

Open Energy Info (EERE)

b>  
Global Horizontal Irradiance
NASA Surface meteorology and Solar Energy (SSE) Release 6.0 Data Set (Jan 2008)
22-year Monthly & Annual Average...

457

Solar: monthly and annual average direct normal irradiance GIS...  

Open Energy Info (EERE)

>  
Direct Normal Irradiance (kWhm2day)
NASA Surface meteorology and Solar Energy (SSE) Release 6.0 Data Set (Jan 2008)
22-year Monthly & Annual Average...

458

Average utilization of the nation's natural gas combined-cycle ...  

U.S. Energy Information Administration (EIA)

... (purple line) and 2010 (red line) average capacity factors for natural gas plant operations between 10 p.m. and 6 a.m. rose from 26% to 32%.

459

STATE OF CALIFORNIA AREA WEIGHTED AVERAGE CALCULATION WORKSHEET: RESIDENTIAL  

E-Print Network (OSTI)

there is more than one level of floor, wall, or ceiling insulation in a building, or more than one type of a building feature, material, or construction assembly occur in a building, a weighted average

460

Solar: monthly and annual average latitude tilt irradiance GIS...  

Open Energy Info (EERE)

& Annual Average (July 1983 - June 2005)
Parameter: Latitude Tilt Radiation (kWhm2day)
Internet: http:eosweb.larc.nasa.govsse
Note 1:...

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Using Bayesian Model Averaging to Calibrate Forecast Ensembles  

Science Conference Proceedings (OSTI)

Ensembles used for probabilistic weather forecasting often exhibit a spread-error correlation, but they tend to be underdispersive. This paper proposes a statistical method for postprocessing ensembles based on Bayesian model averaging (BMA), ...

Adrian E. Raftery; Tilmann Gneiting; Fadoua Balabdaoui; Michael Polakowski

2005-05-01T23:59:59.000Z

462

Pennsylvania Average Price of Natural Gas Delivered to Residential...  

Gasoline and Diesel Fuel Update (EIA)

7 10.55 11.24 13.80 16.87 19.85 1989-2013 Commercial Average Price 9.51 9.87 10.27 11.46 12.38 12.89...

463

Semi-supervised training for the averaged perceptron POS tagger  

Science Conference Proceedings (OSTI)

This paper describes POS tagging experiments with semi-supervised training as an extension to the (supervised) averaged perceptron algorithm, first introduced for this task by (Collins, 2002). Experiments with an iterative training on standard-sized ...

Drahomíra "johanka" Spoustová; Jan Haji?; Jan Raab; Miroslav Spousta

2009-03-01T23:59:59.000Z

464

A Statistical Averaging Method for Wind Profiler Doppler Spectra  

Science Conference Proceedings (OSTI)

A new method is presented for Doppler spectral averaging that more reliably identifies the profiler radar return from clear air in the presence of contamination—for example, from migrating bird echoes. These very sensitive radars profile the wind ...

David A. Merritt

1995-10-01T23:59:59.000Z

465

The averaged control system of fast oscillating control systems  

E-Print Network (OSTI)

For control systems that either have an explicit periodic dependence on time or have periodic solutions and small controls, we define an average control system that takes into account all possible variations of the control, and prove that its solutions approximate all solutions of the oscillating systems as oscillations go faster. The dimension of its velocity set is characterised geomtrically. When it is maximum the average system defines a Finsler metric, unfortunately not twice differntiable in general. Under particular assumptions, valid for the control two body system, this Finsler metric generates a Hamiltonian flow on the cotangent bundle. For minimum time control, this average system proves that averaging the Hamiltonian given by the maximum principle is a valid approximation.

Bombrun, Alex

2011-01-01T23:59:59.000Z

466

Implication of Spatial Averaging in Complex-Terrain Wind Studies  

Science Conference Proceedings (OSTI)

Studies of wind over complex terrain have been conducted at three times and two locations in Northern California. Instrumentation included conventional cup-vane anemometers and optical anemometers with spatial averaging over path lengths of 0.6-1 ...

W. M. Porch

1982-09-01T23:59:59.000Z

467

Vehicle Technologies Office: Fact #638: August 30, 2010 Average...  

NLE Websites -- All DOE Office Websites (Extended Search)

8: August 30, 2010 Average Expenditure for a New Car Declines in Relation to Family Earnings to someone by E-mail Share Vehicle Technologies Office: Fact 638: August 30, 2010...

468

Some Considerations Relevant to Computing Average Hemispheric Temperature Anomalies  

Science Conference Proceedings (OSTI)

Three data bases of gridded surface temperature anomalies were used to assess the sensitivity of the average estimated Northern Hemisphere (NH) temperature anomaly to: 1) extreme gridpoint values and 2) zonal band contributions. Over the last 100 ...

S. L. Grotch

1987-07-01T23:59:59.000Z

469

New Mexico Natural Gas Average Consumption per Industrial Consumer...  

U.S. Energy Information Administration (EIA) Indexed Site

Industrial Consumer (Thousand Cubic Feet) New Mexico Natural Gas Average Consumption per Industrial Consumer (Thousand Cubic Feet) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5...

470

New Mexico Natural Gas Average Consumption per Commercial Consumer...  

U.S. Energy Information Administration (EIA) Indexed Site

Commercial Consumer (Thousand Cubic Feet) New Mexico Natural Gas Average Consumption per Commercial Consumer (Thousand Cubic Feet) Decade Year-0 Year-1 Year-2 Year-3 Year-4 Year-5...

471

Table A44. Average Prices of Purchased Electricity and Steam  

U.S. Energy Information Administration (EIA) Indexed Site

4. Average Prices of Purchased Electricity and Steam" 4. Average Prices of Purchased Electricity and Steam" " by Type of Supplier, Census Region, Census Division, and" " Economic Characteristics of the Establishment, 1994" " (Estimates in Dollars per Physical Units)" ," Electricity",," Steam" ," (kWh)",," (million Btu)" ,,,,,"RSE" ,"Utility","Nonutility","Utility","Nonutility","Row" "Economic Characteristics(a)","Supplier(b)","Supplier(c)","Supplier(b)","Supplier(c)","Factors"

472

Solar: monthly and annual average direct normal (DNI), global horizontal  

Open Energy Info (EERE)

South America from NREL South America from NREL Dataset Summary Description (Abstract): Monthly Average Solar Resource for horizontal and tilted flat-plates, and 2-axis tracking concentrating collectors. (Purpose): Provide information on the solar resource potential for the data domain. The insolation values represent the average solar energy available to solar collectors. (Supplemental Information): These data provide monthly average and annual average daily total solar resource averaged over surface cells of approximately 40 km by 40 km in size. The solar resource value is represented as watt-hours per square meter per day for each month. The data were developed from NREL's Climatological Solar Radiation (CSR) Model. This model uses information on cloud cover, atmospheric water vapor and trace gases, and the amount of aerosols in the atmosphere to calculate the monthly average daily total insolation (sun and sky) falling on a horizontal surface. Existing ground measurement stations are used to validate the data where possible. The modeled values are accurate to approximately 10% of a true measured value within the grid cell due to the uncertainties associated with meteorological input to the model. The local cloud cover can vary significantly even within a single grid cell as a result of terrain effects and other microclimate influences. Furthermore, the uncertainty of the modeled estimates increase with distance from reliable measurement sources and with the complexity of the terrain.

473

Solar: monthly and annual average direct normal (DNI), global horizontal  

Open Energy Info (EERE)

Central America and the Carribean from NREL Central America and the Carribean from NREL Dataset Summary Description (Abstract): Monthly Average Solar Resource for horizontal and tilted flat-plates, and 2-axis tracking concentrating collectors. (Purpose): Provide information on the solar resource potential for the data domain. The insolation values represent the average solar energy available to solar collectors. (Supplemental Information): These data provide monthly average and annual average daily total solar resource averaged over surface cells of approximately 40 km by 40 km in size. The solar resource value is represented as watt-hours per square meter per day for each month. The data were developed from NREL's Climatological Solar Radiation (CSR) Model. This model uses information on cloud cover, atmospheric water vapor and trace gases, and the amount of aerosols in the atmosphere to calculate the monthly average daily total insolation (sun and sky) falling on a horizontal surface. Existing ground measurement stations are used to validate the data where possible. The modeled values are accurate to approximately 10% of a true measured value within the grid cell due to the uncertainties associated with meteorological input to the model. The local cloud cover can vary significantly even within a single grid cell as a result of terrain effects and other microclimate influences. Furthermore, the uncertainty of the modeled estimates increase with distance from reliable measurement sources and with the complexity of the terrain.

474

U.S. Refiner Sales to End Users (Average) Prices  

U.S. Energy Information Administration (EIA) Indexed Site

Sales Type: Sales to End Users, Average Through Retail Outlets Sales for Resale, Average DTW Rack Bulk Sales Type: Sales to End Users, Average Through Retail Outlets Sales for Resale, Average DTW Rack Bulk Download Series History Download Series History Definitions, Sources & Notes Definitions, Sources & Notes Show Data By: Formulation/ Grade Sales Type Apr-13 May-13 Jun-13 Jul-13 Aug-13 Sep-13 View History Conventional, Average 3.030 3.137 3.122 3.063 3.042 2.972 1994-2013 Conventional Regular 3.005 3.116 3.102 3.040 3.017 2.948 1994-2013 Conventional Midgrade 3.167 3.256 3.239 3.200 3.193 3.121 1994-2013 Conventional Premium 3.269 3.354 3.327 3.291 3.274 3.203 1994-2013 Oxygenated, Average - - - - - - 1994-2013 Oxygenated Regular - - - - - - 1994-2013 Oxygenated Midgrade - - - - - - 1994-2013

475

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

High Intensity Discharge Lamps Test Procedures High Intensity Discharge Lamps Test Procedures Sign up for e-mail updates on regulations for this and other products High-intensity discharge (HID) lamps include mercury vapor (MV), metal halide (MH), and high-pressure sodium (HPS) lamps. The Department of Energy (DOE) is establishing test procedures for HID lamps. This rulemaking is mandated by the Energy Policy and Conservation Act (EPCA). ( 42 U.S.C. 6291-6309) This Rulemaking is related to the High-Intensity Discharge Lamps Standard and Test Procedure. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of proposed rulemaking regarding test procedures for HID lamps. 76 FR 77914 (Dec. 15, 2011).

476

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Metal Halide Lamp Fixtures Metal Halide Lamp Fixtures Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of metal halide lamp fixtures since 2007. A metal halide lamp fixture uses a metal halide lamp and a metal halide lamp ballast. The lamp is the light source and the ballast starts and regulates current. Metal halide fixtures or lighting systems provide lighting for parking lots and streets, flood lighting, athletics facilities, big-box stores, and warehouses. The current standards will save approximately 6.4 quads of energy and result in approximately $9.6 billion in energy bill savings for products shipped from 2009-2038. The standard will avoid about 93.6 million metric tons of carbon dioxide emissions.

477

U.S. Department of Energy NEPA Categorical Exclusion Determination Form  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Notice of Proposed Rulemaking for Energy Conservation Standards for Certain Reflector, Elliptical Reflector, Notice of Proposed Rulemaking for Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Reflector Lamps (RIN: 1904-AC15) Program or Field Office:EERE - Buildings Technology Program Location(s} (City/County/State): Nationwide Proposed Action Description: In this NQPR, DOE proposes to adopt new standards for the large diameter Incandescent Reflector Lamps (which will hereafter be referred to as certain "R, ER, and BR IRLs") include: (1) lamps rated 50 watts or less that are ER30, BR30, BR40, or ER40; (2) lamps rated 65 watts that are BR30, BR40, or ER40 lamps; and (3) R20 incandescent reflector lamps rated 45 watts or less. DOE also presents analysis for small diameter lamps and requests further comment on an appropriate standard for these products. The proposed standards, if adopted, would apply to all the

478

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Light Emitting Diode Lamps Light Emitting Diode Lamps Sign up for e-mail updates on regulations for this and other products There are currently no energy conservation standards for light emitting diode (LED) lamps.LED lamps are comprised of an LED source, such as LED packages or LED arrays; an LED driver; an American National Standards Institute (ANSI) standard base, and other optical, thermal, mechanical, and electrical components. These LED lamps are primarily used in residential applications as replacement lamps. The Department of Energy (DOE) will conduct an analysis of the energy, emissions, and costs associated with LEDs during any future energy conservation standard rulemakings. The Standards and Test Procedures for this product are related to Rulemaking for Light-Emitting Diode Lamps Test Procedure.

479

Lighting Research Group: Facilities: Integrating Sphere  

NLE Websites -- All DOE Office Websites (Extended Search)

Integrating Sphere Integrating Sphere integrating sphere Integrating Sphere Gonio-photometer | Integrating sphere | Power analyzer | Spectro-radiometer The integrating sphere is used to quickly measure the total light output of a lamp. The lamp being tested is placed in the center of the integrating sphere. At one side of the sphere is a light meter which measures the light output of the lamp. Between the lamp and the light meter there is a baffle to prevent the meter from seeing any direct light from the lamp. The inside of the sphere (including the baffle) is coated with a very white paint that reflects all wavelengths equally. This allows us to get very accurate measurements. The light from the lamp bounces around the sphere until it reaches the light meter. It is important that nothing else is in the sphere besides the lamp and the

480

Bayesian Model Averaging’s Problematic Treatment of Extreme Weather and a Paradigm Shift That Fixes It  

Science Conference Proceedings (OSTI)

Methods of ensemble postprocessing in which continuous probability density functions are constructed from ensemble forecasts by centering functions around each of the ensemble members have come to be called Bayesian model averaging (BMA) or “...

Craig H. Bishop; Kevin T. Shanley

2008-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "average lamp lamp" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Average Soil Water Retention Curves Measured by Neutron Radiography  

SciTech Connect

Water retention curves are essential for understanding the hydrologic behavior of partially-saturated porous media and modeling flow transport processes within the vadose zone. In this paper we report direct measurements of the main drying and wetting branches of the average water retention function obtained using 2-dimensional neutron radiography. Flint sand columns were saturated with water and then drained under quasi-equilibrium conditions using a hanging water column setup. Digital images (2048 x 2048 pixels) of the transmitted flux of neutrons were acquired at each imposed matric potential (~10-15 matric potential values per experiment) at the NCNR BT-2 neutron imaging beam line. Volumetric water contents were calculated on a pixel by pixel basis using Beer-Lambert s law after taking into account beam hardening and geometric corrections. To remove scattering effects at high water contents the volumetric water contents were normalized (to give relative saturations) by dividing the drying and wetting sequences of images by the images obtained at saturation and satiation, respectively. The resulting pixel values were then averaged and combined with information on the imposed basal matric potentials to give average water retention curves. The average relative saturations obtained by neutron radiography showed an approximate one-to-one relationship with the average values measured volumetrically using the hanging water column setup. There were no significant differences (at p < 0.05) between the parameters of the van Genuchten equation fitted to the average neutron radiography data and those estimated from replicated hanging water column data. Our results indicate that neutron imaging is a very effective tool for quantifying the average water retention curve.

Cheng, Chu-Lin [ORNL; Perfect, Edmund [University of Tennessee, Knoxville (UTK); Kang, Misun [ORNL; Voisin, Sophie [ORNL; Bilheux, Hassina Z [ORNL; Horita, Juske [Texas Tech University (TTU); Hussey, Dan [NIST Center for Neutron Research (NCRN), Gaithersburg, MD

2011-01-01T23:59:59.000Z

482

"2012 Average Monthly Bill- Residential"  

U.S. Energy Information Administration (EIA) Indexed Site

Residential" Residential" "(Data from forms EIA-861- schedules 4A-D, EIA-861S and EIA-861U)" "State","Number of Customers","Average Monthly Consumption (kWh)","Average Price (cents/kWh)","Average Monthly Bill (Dollar and cents)" "New England",6203726,634.13095,15.713593,99.644755 "Connecticut",1454651,730.85302,17.343298,126.75402 "Maine",703770,530.56349,14.658797,77.774225 "Massachusetts",2699141,627.15845,14.912724,93.52641 "New Hampshire",601697,614.81776,16.070168,98.802249 "Rhode Island",435448,597.34783,14.404061,86.042344 "Vermont",309019,565.03618,17.006075,96.090478 "Middle Atlantic",15727423,700.63673,15.272654,107.00582

483

"2012 Average Monthly Bill- Industrial"  

U.S. Energy Information Administration (EIA) Indexed Site

Industrial" Industrial" "(Data from forms EIA-861- schedules 4A-D, EIA-861S and EIA-861U)" "State","Number of Customers","Average Monthly Consumption (kWh)","Average Price (cents/kWh)","Average Monthly Bill (Dollar and cents)" "New England",34164,67854.037,11.83487,8030.4373 "Connecticut",4647,63947.063,12.672933,8103.9685 "Maine",2780,90741.457,7.9819499,7242.9376 "Massachusetts",21145,66710.826,12.566635,8383.3057 "New Hampshire",3444,47247.217,11.83228,5590.423 "Rhode Island",1927,39935.911,10.676724,4263.8471 "Vermont",221,536044.12,9.9796777,53495.475 "Middle Atlantic",45836,126368.14,7.4903534,9465.42 "New Jersey",12729,50817.89,10.516509,5344.2677

484

Globally Averaged Atmospheric CFC-11 Concentrations: Monthly and Annual  

NLE Websites -- All DOE Office Websites (Extended Search)

Chlorofluorocarbons » Chlorofluorocarbons » Atmospheric CFC-11 Concentrations Globally Averaged Atmospheric CFC-11 Concentrations: Monthly and Annual Data for the Period 1975-1992 DOI: 10.3334/CDIAC/atg.db1010 data Data (DB1010) Investigator M. A. K. Khalil and R. A. Rasmussen Description This data set presents globally averaged atmospheric concentrations of chlorofluorocarbon 11, known also as CFC-11 or F-11 (chemical name: trichlorofluoromethane; formula: CCl3F). The monthly global average data are derived from flask air samples collected at eight sites in six locations over the period August 1980-July 1992. The sites are Barrow (Alaska), Cape Meares (Oregon), Cape Kumukahi and Mauna Loa (Hawaii), Cape Matatula (American Samoa), Cape Grim (Tasmania), Palmer Station, and the

485

INVERSIONS FOR AVERAGE SUPERGRANULAR FLOWS USING FINITE-FREQUENCY KERNELS  

Science Conference Proceedings (OSTI)

I analyze the maps recording the travel-time shifts caused by averaged plasma anomalies under an 'average supergranule', constructed by means of statistical averaging over 5582 individual supergranules with large divergence signals detected in two months of Helioseismic and Magnetic Imager Dopplergrams. By utilizing a three-dimensional validated time-distance inversion code, I measure a peak vertical velocity of 117 {+-} 2 m s{sup -1} at depths around 1.2 Mm in the center of the supergranule and a root-mean-square vertical velocity of 21 m s{sup -1} over the area of the supergranule. A discrepancy between this measurement and the measured surface vertical velocity (a few m s{sup -1}) can be explained by the existence of the large-amplitude vertical flow under the surface of supergranules with large divergence signals, recently suggested by Duvall and Hanasoge.

Svanda, Michal, E-mail: michal@astronomie.cz [Astronomical Institute, Academy of Sciences of the Czech Republic (v.v.i.), Fricova 298, CZ-25165 Ondrejov (Czech Republic)

2012-11-10T23:59:59.000Z

486

Comparison of Average Transport and Dispersion Among a Gaussian, a  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Comparison of Average Transport and Dispersion Among a Gaussian, a Comparison of Average Transport and Dispersion Among a Gaussian, a Two-Dimensional, and a Three-Dimensional Model Comparison of Average Transport and Dispersion Among a Gaussian, a Two-Dimensional, and a Three-Dimensional Model The Nuclear Regulatory Commission's (NRC's) code for predicting off-site consequences, MACCS2 (Chanin, et al. 1998) (MELCOR Accident Consequence Code System, Version 2), uses a simplified model for atmospheric transport and d ispersion (ATD), that is, a straight-line Gaussian model. The MACCS2 calculations are used by the NRC for planning purposes, for cost-benefit analyses, and in level-3 probabilistic risk analyses (PRAs). The MACCS2 ATD model has been criticized as being overly simplistic, even for its purposes. The justification for its use has been

487

Flavor Physics Data from the Heavy Flavor Averaging Group (HFAG)  

DOE Data Explorer (OSTI)

The Heavy Flavor Averaging Group (HFAG) was established at the May 2002 Flavor Physics and CP Violation Conference in Philadelphia, and continues the LEP Heavy Flavor Steering Group's tradition of providing regular updates to the world averages of heavy flavor quantities. Data are provided by six subgroups that each focus on a different set of heavy flavor measurements: B lifetimes and oscillation parameters, Semi-leptonic B decays, Rare B decays, Unitarity triangle parameters, B decays to charm final states, and Charm Physics.

Heavy Flavor Averaging Group (HFAG)

488

Bounce-averaged Fokker-Planck code for stellarator transport  

Science Conference Proceedings (OSTI)

A computer code for solving the bounce-averaged Fokker-Planck equation appropriate to stellarator transport has been developed, and its first applications made. The code is much faster than the bounce-averaged Monte-Carlo codes, which up to now have provided the most efficient numerical means for studying stellarator transport. Moreover, because the connection to analytic kinetic theory of the Fokker-Planck approach is more direct than for the Monte-Carlo approach, a comparison of theory and numerical experiment is now possible at a considerably more detailed level than previously.

Mynick, H.E.; Hitchon, W.N.G.

1985-07-01T23:59:59.000Z

489

AMPERE AVERAGE CURRENT PHOTOINJECTOR AND ENERGY RECOVERY LINAC.  

SciTech Connect

High-power Free-Electron Lasers were made possible by advances in superconducting linac operated in an energy-recovery mode. In order to get to much higher power levels, say a fraction of a megawatt average power, many technological barriers are yet to be broken. We describe work on CW, high-current and high-brightness electron beams. This will include a description of a superconducting, laser-photocathode RF gun employing a new secondary-emission multiplying cathode, an accelerator cavity, both capable of producing of the order of one ampere average current and plans for an ERL based on these units.

BEN-ZVI,I.; BURRILL,A.; CALAGA,R.; ET AL.

2004-08-17T23:59:59.000Z

490

Residual Fuel Oil Prices, Average - Sales to End Users  

U.S. Energy Information Administration (EIA) Indexed Site

Product/Sales Type: Residual Fuel, Average - Sales to End Users Residual Fuel, Average - Sales for Resale Sulfur Less Than or Equal to 1% - Sales to End Users Sulfur Less Than or Equal to 1% - Sales for Resale Sulfur Greater Than 1% - Sales to End Users Sulfur Greater Than 1% - Sales for Resale Period: Monthly Annual Product/Sales Type: Residual Fuel, Average - Sales to End Users Residual Fuel, Average - Sales for Resale Sulfur Less Than or Equal to 1% - Sales to End Users Sulfur Less Than or Equal to 1% - Sales for Resale Sulfur Greater Than 1% - Sales to End Users Sulfur Greater Than 1% - Sales for Resale Period: Monthly Annual Download Series History Download Series History Definitions, Sources & Notes Definitions, Sources & Notes Show Data By: Product/Sales Type Area Apr-13 May-13 Jun-13 Jul-13 Aug-13 Sep-13 View History U.S. - - - - - - 1983-2013 East Coast (PADD 1) - - - - - - 1983-2013 New England (PADD 1A) - - - - - - 1983-2013 Connecticut - - - - - - 1983-2013 Maine - - - - - - 1983-2013 Massachusetts - - - - - - 1983-2013

491

HIGH AVERAGE POWER UV FREE ELECTRON LASER EXPERIMENTS AT JLAB  

Science Conference Proceedings (OSTI)

Having produced 14 kW of average power at {approx}2 microns, JLAB has shifted its focus to the ultraviolet portion of the spectrum. This presentation will describe the JLab UV Demo FEL, present specifics of its driver ERL, and discuss the latest experimental results from FEL experiments and machine operations.

Douglas, David; Evtushenko, Pavel; Gubeli, Joseph; Hernandez-Garcia, Carlos; Legg, Robert; Neil, George; Powers, Thomas; Shinn, Michelle D; Tennant, Christopher

2012-07-01T23:59:59.000Z

492

Information Leakage via Electromagnetic Emanation and Effectiveness of Averaging Technique  

Science Conference Proceedings (OSTI)

It is well known that there is relationship between electromagnetic emanation and processing information in IT devices such as personal computers and smart cards. In this paper, we show how to estimate amount of information that is leaked as electromagnetic ... Keywords: Tempest, Channel capacity, electromagnetic emanation, averaging technique

Hidema Tanaka

2008-04-01T23:59:59.000Z

493

Spatial analysis based on variance of moving window averages  

E-Print Network (OSTI)

R02 R04 R06 R08 R16 I n Window size B R02 R06 R10 R14 R20R04 R08 R12 R16 R24 R36 I n Window size Wu et al. , Fig. 2Based on Variance of Moving Window Averages B. M. Wu, K. V.

Wu, B M; Subbarao, K V; Ferrandino, F J; Hao, J J

2006-01-01T23:59:59.000Z

494

Table WF01. Average Consumer Prices and Expenditures for ...  

U.S. Energy Information Administration (EIA)

Heating Oil U.S. Average Consumption (gallons) 522.7 531.7 572.5 538.2 574.1 465.3 539.9 546.9 1.3 ... Wood 2,094 2,179 2,353 2,424 2,454 2,520 2,582 ...

495

Using Bayesian Model Averaging to Calibrate Forecast Ensembles 1  

E-Print Network (OSTI)

Using Bayesian Model Averaging to Calibrate Forecast Ensembles 1 Adrian E. Raftery, Fadoua forecasting often exhibit a spread-skill relationship, but they tend to be underdispersive. This paper of PDFs centered around the individual (possibly bias-corrected) forecasts, where the weights are equal

Washington at Seattle, University of

496

A Vertically Averaged Circulation Model Using Boundary-Fitted Coordinates  

Science Conference Proceedings (OSTI)

A two-dimensional vertically averaged circulation model using boundary-fitted coordinates has been developed for predicting sea level and currants in estuarine and shelf waters. The basic idea of the approach is to use a set of coupled quasi-...

Malcolm L. Spaulding

1984-05-01T23:59:59.000Z

497

Pennsylvania Average Price of Natural Gas Delivered to Residential...  

U.S. Energy Information Administration (EIA) Indexed Site

Percent Sold by Local Distribution Companies 91.2 91.2 2006-2011 Commercial Average Price 12.77 14.29 11.83 10.47 10.42 10.21 1967-2012 Local Distribution Companies 11.29 NA...

498

Michigan Average Price of Natural Gas Delivered to Residential...  

Annual Energy Outlook 2012 (EIA)

8.75 8.56 9.26 11.63 12.68 13.68 1989-2013 Commercial Average Price 7.67 7.51 7.84 8.78 9.69 10.30...

499

High average power diode pumped solid state lasers for CALIOPE  

Science Conference Proceedings (OSTI)

Diode pumping of solid state media offers the opportunity for very low maintenance, high efficiency, and compact laser systems. For remote sensing, such lasers may be used to pump tunable non-linear sources, or if tunable themselves, act directly or through harmonic crystals as the probe. The needs of long range remote sensing missions require laser performance in the several watts to kilowatts range. At these power performance levels, more advanced thermal management technologies are required for the diode pumps. The solid state laser design must now address a variety of issues arising from the thermal loads, including fracture limits, induced lensing and aberrations, induced birefringence, and laser cavity optical component performance degradation with average power loading. In order to highlight the design trade-offs involved in addressing the above issues, a variety of existing average power laser systems are briefly described. Included are two systems based on Spectra Diode Laboratory`s water impingement cooled diode packages: a two times diffraction limited, 200 watt average power, 200 Hz multi-rod laser/amplifier by Fibertek, and TRW`s 100 watt, 100 Hz, phase conjugated amplifier. The authors also present two laser systems built at Lawrence Livermore National Laboratory (LLNL) based on their more aggressive diode bar cooling package, which uses microchannel cooler technology capable of 100% duty factor operation. They then present the design of LLNL`s first generation OPO pump laser for remote sensing. This system is specified to run at 100 Hz, 20 nsec pulses each with 300 mJ, less than two times diffraction limited, and with a stable single longitudinal mode. The performance of the first testbed version will be presented. The authors conclude with directions their group is pursuing to advance average power lasers. This includes average power electro-optics, low heat load lasing media, and heat capacity lasers.

Comaskey, B.; Halpin, J.; Moran, B.

1994-07-01T23:59:59.000Z

500

Nonlocal imaging by conditional averaging of random reference measurements  

E-Print Network (OSTI)

We report the nonlocal imaging of an object by conditional averaging of the random exposure frames of a reference detector, which only sees the freely propagating field from a thermal light source. A bucket detector, synchronized with the reference detector, records the intensity fluctuations of an identical beam passing through the object mask. These fluctuations are sorted according to their values relative to the mean, then the reference data in the corresponding time-bins for a given fluctuation range are averaged, to produce either positive or negative images. Since no correlation calculations are involved, this correspondence imaging technique challenges our former interpretations of "ghost" imaging. Compared with conventional correlation imaging or compressed sensing schemes, both the number of exposures and computation time are greatly reduced, while the visibility is much improved. A simple statistical model is presented to explain the phenomenon.

Kai-Hong Luo; Boqiang Huang; Wei-Mou Zheng; Ling-An Wu

2013-03-22T23:59:59.000Z