National Library of Energy BETA

Sample records for average absolute difference

  1. Variable Average Absolute Percent Differences

    U.S. Energy Information Administration (EIA) Indexed Site

    Variable Average Absolute Percent Differences Percent of Projections Over- Estimated Gross Domestic Product Real Gross Domestic Product (Average Cumulative Growth)* (Table 2) 0.9 45.8 Petroleum Imported Refiner Acquisition Cost of Crude Oil (Constant $) (Table 3a) 37.7 17.3 Imported Refiner Acquisition Cost of Crude Oil (Nominal $) (Table 3b) 36.6 18.7 Total Petroleum Consumption (Table 4) 7.9 70.7 Crude Oil Production (Table 5) 8.1 51.1 Petroleum Net Imports (Table 6) 24.7 73.8 Natural Gas

  2. "Variable","Average Absolute Percent Differences","Percent of...

    U.S. Energy Information Administration (EIA) Indexed Site

    Annual Energy Outlook Retrospective Review, 2014" "Variable","Average Absolute Percent Differences","Percent of Projections Over- Estimated" "Gross Domestic Product" "Real Gross ...

  3. Impacts of different data averaging times on statistical analysis of distributed domestic photovoltaic systems

    SciTech Connect (OSTI)

    Widen, Joakim; Waeckelgaard, Ewa; Paatero, Jukka; Lund, Peter

    2010-03-15

    The trend of increasing application of distributed generation with solar photovoltaics (PV-DG) suggests that a widespread integration in existing low-voltage (LV) grids is possible in the future. With massive integration in LV grids, a major concern is the possible negative impacts of excess power injection from on-site generation. For power-flow simulations of such grid impacts, an important consideration is the time resolution of demand and generation data. This paper investigates the impact of time averaging on high-resolution data series of domestic electricity demand and PV-DG output and on voltages in a simulated LV grid. Effects of 10-minutely and hourly averaging on descriptive statistics and duration curves were determined. Although time averaging has a considerable impact on statistical properties of the demand in individual households, the impact is smaller on aggregate demand, already smoothed from random coincidence, and on PV-DG output. Consequently, the statistical distribution of simulated grid voltages was also robust against time averaging. The overall judgement is that statistical investigation of voltage variations in the presence of PV-DG does not require higher resolution than hourly. (author)

  4. Absolute nuclear material assay

    DOE Patents [OSTI]

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  5. Absolute nuclear material assay

    DOE Patents [OSTI]

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2012-05-15

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  6. The absolute path command

    Energy Science and Technology Software Center (OSTI)

    2012-05-11

    The ap command traveres all symlinks in a given file, directory, or executable name to identify the final absolute path. It can print just the final path, each intermediate link along with the symlink chan, and the permissions and ownership of each directory component in the final path. It has functionality similar to "which", except that it shows the final path instead of the first path. It is also similar to "pwd", but it canmore » provide the absolute path to a relative directory from the current working directory.« less

  7. Measurement of the absolute \

    SciTech Connect (OSTI)

    Aunion, Jose Luis Alcaraz; /Barcelona, IFAE

    2010-07-01

    This thesis presents the measurement of the charged current quasi-elastic (CCQE) neutrino-nucleon cross section at neutrino energies around 1 GeV. This measurement has two main physical motivations. On one hand, the neutrino-nucleon interactions at few GeV is a region where existing old data are sparse and with low statistics. The current measurement populates low energy regions with higher statistics and precision than previous experiments. On the other hand, the CCQE interaction is the most useful interaction in neutrino oscillation experiments. The CCQE channel is used to measure the initial and final neutrino fluxes in order to determine the neutrino fraction that disappeared. The neutrino oscillation experiments work at low neutrino energies, so precise measurement of CCQE interactions are essential for flux measurements. The main goal of this thesis is to measure the CCQE absolute neutrino cross section from the SciBooNE data. The SciBar Booster Neutrino Experiment (SciBooNE) is a neutrino and anti-neutrino scattering off experiment. The neutrino energy spectrum works at energies around 1 GeV. SciBooNE was running from June 8th 2007 to August 18th 2008. In that period, the experiment collected a total of 2.65 x 10{sup 20} protons on target (POT). This thesis has used full data collection in neutrino mode 0.99 x 10{sup 20} POT. A CCQE selection cut has been performed, achieving around 70% pure CCQE sample. A fit method has been exclusively developed to determine the absolute CCQE cross section, presenting results in a neutrino energy range from 0.2 to 2 GeV. The results are compatible with the NEUT predictions. The SciBooNE measurement has been compared with both Carbon (MiniBoonE) and deuterium (ANL and BNL) target experiments, showing a good agreement in both cases.

  8. Accelerating Monte Carlo molecular simulations by reweighting and reconstructing Markov chains: Extrapolation of canonical ensemble averages and second derivatives to different temperature and density conditions

    SciTech Connect (OSTI)

    Kadoura, Ahmad; Sun, Shuyu Salama, Amgad

    2014-08-01

    Accurate determination of thermodynamic properties of petroleum reservoir fluids is of great interest to many applications, especially in petroleum engineering and chemical engineering. Molecular simulation has many appealing features, especially its requirement of fewer tuned parameters but yet better predicting capability; however it is well known that molecular simulation is very CPU expensive, as compared to equation of state approaches. We have recently introduced an efficient thermodynamically consistent technique to regenerate rapidly Monte Carlo Markov Chains (MCMCs) at different thermodynamic conditions from the existing data points that have been pre-computed with expensive classical simulation. This technique can speed up the simulation more than a million times, making the regenerated molecular simulation almost as fast as equation of state approaches. In this paper, this technique is first briefly reviewed and then numerically investigated in its capability of predicting ensemble averages of primary quantities at different neighboring thermodynamic conditions to the original simulated MCMCs. Moreover, this extrapolation technique is extended to predict second derivative properties (e.g. heat capacity and fluid compressibility). The method works by reweighting and reconstructing generated MCMCs in canonical ensemble for Lennard-Jones particles. In this paper, system's potential energy, pressure, isochoric heat capacity and isothermal compressibility along isochors, isotherms and paths of changing temperature and density from the original simulated points were extrapolated. Finally, an optimized set of Lennard-Jones parameters (?, ?) for single site models were proposed for methane, nitrogen and carbon monoxide.

  9. Absolute intensity calibration of the 32-channel heterodyne radiometer on experimental advanced superconducting tokamak

    SciTech Connect (OSTI)

    Liu, X.; Zhao, H. L.; Liu, Y. Li, E. Z.; Han, X.; Ti, A.; Hu, L. Q.; Zhang, X. D.; Domier, C. W.; Luhmann, N. C.

    2014-09-15

    This paper presents the results of the in situ absolute intensity calibration for the 32-channel heterodyne radiometer on the experimental advanced superconducting tokamak. The hot/cold load method is adopted, and the coherent averaging technique is employed to improve the signal to noise ratio. Measured spectra and electron temperature profiles are compared with those from an independent calibrated Michelson interferometer, and there is a relatively good agreement between the results from the two different systems.

  10. Neutron resonance averaging

    SciTech Connect (OSTI)

    Chrien, R.E.

    1986-10-01

    The principles of resonance averaging as applied to neutron capture reactions are described. Several illustrations of resonance averaging to problems of nuclear structure and the distribution of radiative strength in nuclei are provided. 30 refs., 12 figs.

  11. Average Residential Price

    U.S. Energy Information Administration (EIA) Indexed Site

    Data Series: Average Residential Price Residential Price - Local Distribution Companies Residential Price - Marketers Residential % Sold by Local Distribution Companies Average Commercial Price Commercial Price - Local Distribution Companies Commerical Price - Marketers Commercial % Sold by Local Distribution Companies Period: Monthly Annual Download Series History Download Series History Definitions, Sources & Notes Definitions, Sources & Notes Show Data By: Data Series Area 2010 2011

  12. Absolute calibration of optical flats

    DOE Patents [OSTI]

    Sommargren, Gary E.

    2005-04-05

    The invention uses the phase shifting diffraction interferometer (PSDI) to provide a true point-by-point measurement of absolute flatness over the surface of optical flats. Beams exiting the fiber optics in a PSDI have perfect spherical wavefronts. The measurement beam is reflected from the optical flat and passed through an auxiliary optic to then be combined with the reference beam on a CCD. The combined beams include phase errors due to both the optic under test and the auxiliary optic. Standard phase extraction algorithms are used to calculate this combined phase error. The optical flat is then removed from the system and the measurement fiber is moved to recombine the two beams. The newly combined beams include only the phase errors due to the auxiliary optic. When the second phase measurement is subtracted from the first phase measurement, the absolute phase error of the optical flat is obtained.

  13. Absolut Energy Capital | Open Energy Information

    Open Energy Info (EERE)

    Absolut Energy Capital Jump to: navigation, search Name: Absolut Energy Capital Place: London, England, United Kingdom Zip: W1H - 6HN Sector: Renewable Energy Product: London-based...

  14. Absolute Energy USA | Open Energy Information

    Open Energy Info (EERE)

    USA Jump to: navigation, search Name: Absolute Energy (USA) Place: St. Ansgar, Iowa Zip: 50472 Product: Absolute Energy has built a 100 million gallon per year ethanol plant on the...

  15. Concentration Averaging | Department of Energy

    Office of Environmental Management (EM)

    Concentration Averaging Concentration Averaging Summary Notes from 3 October 2007 Generic Technical Issue Discussion on Concentration Averaging PDF icon Summary Notes from 3...

  16. Analysis of standard reference materials by absolute INAA

    SciTech Connect (OSTI)

    Heft, R.E.; Koszykowski, R.F.

    1981-07-01

    Three standard reference materials, flyash, soil, and ASI 4340 steel, were analyzed by a method of absolute instrumental neutron activation analysis (INAA). Two different light water pool-type reactors were used to produce equivalent analytical results even though the epithermal to thermal flux ratio in one reactor was higher than that in the other by a factor of two.

  17. Absolute Energy Capital | Open Energy Information

    Open Energy Info (EERE)

    Capital Jump to: navigation, search Name: Absolute Energy Capital Place: London, United Kingdom Zip: SW1Y 5NQ Product: London-based private equity firm. Coordinates: 51.506325,...

  18. ARM - Field Campaign - Absolute Solar Transmittance Interferometer...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    govCampaignsAbsolute Solar Transmittance Interferometer (ASTI) ARM Data Discovery Browse Data Comments? We would love to hear from you Send us a note below or call us at ...

  19. Absolute charge calibration of scintillating screens for relativistic electron detection

    SciTech Connect (OSTI)

    Buck, A.; Popp, A.; Schmid, K.; Karsch, S.; Krausz, F.; Zeil, K.; Jochmann, A.; Kraft, S. D.; Sauerbrey, R.; Cowan, T.; Schramm, U.; Hidding, B.; Kudyakov, T.; Sears, C. M. S.; Veisz, L.; Pawelke, J.

    2010-03-15

    We report on new charge calibrations and linearity tests with high-dynamic range for eight different scintillating screens typically used for the detection of relativistic electrons from laser-plasma based acceleration schemes. The absolute charge calibration was done with picosecond electron bunches at the ELBE linear accelerator in Dresden. The lower detection limit in our setup for the most sensitive scintillating screen (KODAK Biomax MS) was 10 fC/mm{sup 2}. The screens showed a linear photon-to-charge dependency over several orders of magnitude. An onset of saturation effects starting around 10-100 pC/mm{sup 2} was found for some of the screens. Additionally, a constant light source was employed as a luminosity reference to simplify the transfer of a one-time absolute calibration to different experimental setups.

  20. Organic Solar Cells: Absolute Measurement of Domain Composition...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Organic Solar Cells: Absolute Measurement of Domain Composition and Nanoscale Size Distribution Explains Performance in Solar Cells Organic Solar Cells: Absolute Measurement of...

  1. Spacetime averaged null energy condition

    SciTech Connect (OSTI)

    Urban, Douglas; Olum, Ken D.

    2010-06-15

    The averaged null energy condition has known violations for quantum fields in curved space, even when one considers only achronal geodesics. Many such examples involve rapid variation in the stress-energy tensor in the vicinity of the geodesic under consideration, giving rise to the possibility that averaging in additional dimensions would yield a principle universally obeyed by quantum fields. However, after discussing various procedures for additional averaging, including integrating over all dimensions of the manifold, we give here a class of examples that violate any such averaged condition.

  2. High average power pockels cell

    DOE Patents [OSTI]

    Daly, Thomas P.

    1991-01-01

    A high average power pockels cell is disclosed which reduces the effect of thermally induced strains in high average power laser technology. The pockels cell includes an elongated, substantially rectangular crystalline structure formed from a KDP-type material to eliminate shear strains. The X- and Y-axes are oriented substantially perpendicular to the edges of the crystal cross-section and to the C-axis direction of propagation to eliminate shear strains.

  3. Spacetime Average Density (SAD) cosmological measures

    SciTech Connect (OSTI)

    Page, Don N.

    2014-11-01

    The measure problem of cosmology is how to obtain normalized probabilities of observations from the quantum state of the universe. This is particularly a problem when eternal inflation leads to a universe of unbounded size so that there are apparently infinitely many realizations or occurrences of observations of each of many different kinds or types, making the ratios ambiguous. There is also the danger of domination by Boltzmann Brains. Here two new Spacetime Average Density (SAD) measures are proposed, Maximal Average Density (MAD) and Biased Average Density (BAD), for getting a finite number of observation occurrences by using properties of the Spacetime Average Density (SAD) of observation occurrences to restrict to finite regions of spacetimes that have a preferred beginning or bounce hypersurface. These measures avoid Boltzmann brain domination and appear to give results consistent with other observations that are problematic for other widely used measures, such as the observation of a positive cosmological constant.

  4. Absolute and relative dosimetry for ELIMED

    SciTech Connect (OSTI)

    Cirrone, G. A. P.; Schillaci, F.; Scuderi, V.; Cuttone, G.; Candiano, G.; Musumarra, A.; Pisciotta, P.; Romano, F.; Carpinelli, M.; Presti, D. Lo; Raffaele, L.; Tramontana, A.; Cirio, R.; Sacchi, R.; Monaco, V.; Marchetto, F.; Giordanengo, S.

    2013-07-26

    The definition of detectors, methods and procedures for the absolute and relative dosimetry of laser-driven proton beams is a crucial step toward the clinical use of this new kind of beams. Hence, one of the ELIMED task, will be the definition of procedures aiming to obtain an absolute dose measure at the end of the transport beamline with an accuracy as close as possible to the one required for clinical applications (i.e. of the order of 5% or less). Relative dosimetry procedures must be established, as well: they are necessary in order to determine and verify the beam dose distributions and to monitor the beam fluence and the energetic spectra during irradiations. Radiochromic films, CR39, Faraday Cup, Secondary Emission Monitor (SEM) and transmission ionization chamber will be considered, designed and studied in order to perform a fully dosimetric characterization of the ELIMED proton beam.

  5. Absolute nuclear material assay using count distribution (LAMBDA) space

    DOE Patents [OSTI]

    Prasad, Mano K.; Snyderman, Neal J.; Rowland, Mark S.

    2015-12-01

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  6. Absolute nuclear material assay using count distribution (LAMBDA) space

    DOE Patents [OSTI]

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  7. Biochip Image Grid Normalization Absolute Signal Fluorescence Measurement Using

    Energy Science and Technology Software Center (OSTI)

    2001-04-17

    This software was developed to measure absolute fluorescent intensities of gel pads on a microchip in units defined by a standard fluorescent slide. It can accomodate varying measurement conditions (e.g. exposure time, sensitivity of detector, resolution of detector, etc.) as well as fluorescent microscopes with non-uniform sensitivity across their field of view allowing the user to compare measurements done on different detectors with varying exposure times, sensitivities, and resolutions. The software is designed both tomore » operate Roper Scientific, Inc. cameras and to use image files produced by the program supplied with that equipment for its calculations. the intensity of the gel pad signal is computed so as to reduce background influence.« less

  8. Two-Sensor System for Absolute Age and Temperature History -...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    PDF Document Publication Market Sheet (718 KB) Technology Marketing Summary Numerous commercial and military applications require knowing the absolute age andor temperature ...

  9. A targeted proteomics toolkit for high-throughput absolute quantificat...

    Office of Scientific and Technical Information (OSTI)

    targeted proteomics toolkit for high-throughput absolute quantification of Escherichia coli proteins Citation Details In-Document Search Title: A targeted proteomics toolkit for ...

  10. An absolute calibration method of an ethyl alcohol biosensor...

    Office of Scientific and Technical Information (OSTI)

    biosensor based on wavelength-modulated differential photothermal radiometry Citation Details In-Document Search Title: An absolute calibration method of an ethyl alcohol biosensor ...

  11. Absolute Cavity Pyrgeometer to Measure the Absolute Outdoor Longwave Irradiance with Traceability to International System of Units, SI

    SciTech Connect (OSTI)

    Reda, I.; Zeng, J.; Scheuch, J.; Hanssen, L.; Wilthan, B.; Myers, D.; Stoffel, T.

    2012-03-01

    This article describes a method of measuring the absolute outdoor longwave irradiance using an absolute cavity pyrgeometer (ACP), U.S. Patent application no. 13/049, 275. The ACP consists of domeless thermopile pyrgeometer, gold-plated concentrator, temperature controller, and data acquisition. The dome was removed from the pyrgeometer to remove errors associated with dome transmittance and the dome correction factor. To avoid thermal convection and wind effect errors resulting from using a domeless thermopile, the gold-plated concentrator was placed above the thermopile. The concentrator is a dual compound parabolic concentrator (CPC) with 180{sup o} view angle to measure the outdoor incoming longwave irradiance from the atmosphere. The incoming irradiance is reflected from the specular gold surface of the CPC and concentrated on the 11 mm diameter of the pyrgeometer's blackened thermopile. The CPC's interior surface design and the resulting cavitation result in a throughput value that was characterized by the National Institute of Standards and Technology. The ACP was installed horizontally outdoor on an aluminum plate connected to the temperature controller to control the pyrgeometer's case temperature. The responsivity of the pyrgeometer's thermopile detector was determined by lowering the case temperature and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The responsivity is then used to calculate the absolute atmospheric longwave irradiance with an uncertainty estimate (U{sub 95}) of {+-}3.96 W m{sup 02} with traceability to the International System of Units, SI. The measured irradiance was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the Interim World Infrared Standard Group, WISG. A total of 408 readings were collected over three different nights. The calculated irradiance measured by the ACP was 1.5 W/m{sup 2} lower than that

  12. Organic Solar Cells: Absolute Measurement of Domain Composition and

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Nanoscale Size Distribution Explains Performance in Solar Cells Organic Solar Cells: Absolute Measurement of Domain Composition and Nanoscale Size Distribution Explains Performance in Solar Cells Organic Solar Cells: Absolute Measurement of Domain Composition and Nanoscale Size Distribution Explains Performance in Solar Cells Print Tuesday, 22 January 2013 00:00 This front cover represents the morphology and resulting device dynamics in organic solar cell blend films of PTB7 and PC71BM, as

  13. Precision absolute-value amplifier for a precision voltmeter

    DOE Patents [OSTI]

    Hearn, W.E.; Rondeau, D.J.

    1982-10-19

    Bipolar inputs are afforded by the plus inputs of first and second differential input amplifiers. A first gain determining resistor is connected between the minus inputs of the differential amplifiers. First and second diodes are connected between the respective minus inputs and the respective outputs of the differential amplifiers. First and second FETs have their gates connected to the outputs of the amplifiers, while their respective source and drain circuits are connected between the respective minus inputs and an output lead extending to a load resistor. The output current through the load resistor is proportional to the absolute value of the input voltage difference between the bipolar input terminals. A third differential amplifier has its plus input terminal connected to the load resistor. A second gain determining resistor is connected between the minus input of the third differential amplifier and a voltage source. A third FET has its gate connected to the output of the third amplifier. The source and drain circuit of the third transistor is connected between the minus input of the third amplifier and a voltage-frequency converter, constituting an output device. A polarity detector is also provided, comprising a pair of transistors having their inputs connected to the outputs of the first and second differential amplifiers. The outputs of the polarity detector are connected to gates which switch the output of the voltage-frequency converter between up and down counting outputs.

  14. Precision absolute value amplifier for a precision voltmeter

    DOE Patents [OSTI]

    Hearn, William E.; Rondeau, Donald J.

    1985-01-01

    Bipolar inputs are afforded by the plus inputs of first and second differential input amplifiers. A first gain determining resister is connected between the minus inputs of the differential amplifiers. First and second diodes are connected between the respective minus inputs and the respective outputs of the differential amplifiers. First and second FETs have their gates connected to the outputs of the amplifiers, while their respective source and drain circuits are connected between the respective minus inputs and an output lead extending to a load resister. The output current through the load resister is proportional to the absolute value of the input voltage difference between the bipolar input terminals. A third differential amplifier has its plus input terminal connected to the load resister. A second gain determining resister is connected between the minus input of the third differential amplifier and a voltage source. A third FET has its gate connected to the output of the third amplifier. The source and drain circuit of the third transistor is connected between the minus input of the third amplifier and a voltage-frequency converter, constituting an output device. A polarity detector is also provided, comprising a pair of transistors having their inputs connected to the outputs of the first and second differential amplifiers. The outputs of the polarity detector are connected to gates which switch the output of the voltage-frequency converter between up and down counting outputs.

  15. Average and effective Q-values for fission product average (n...

    Office of Scientific and Technical Information (OSTI)

    Average and effective Q-values for fission product average (n,2n) and (n,3n) reaction cross sections Citation Details In-Document Search Title: Average and effective Q-values for ...

  16. Average and effective Q-values for fission product average (n...

    Office of Scientific and Technical Information (OSTI)

    Technical Report: Average and effective Q-values for fission product average (n,2n) and (n,3n) reaction cross sections Citation Details In-Document Search Title: Average and ...

  17. ,"Selected National Average Natural Gas Prices"

    U.S. Energy Information Administration (EIA) Indexed Site

    Selected National Average Natural Gas Prices" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description"," Of Series","Frequency","Latest Data for" ,"Data ...

  18. Dynamic Multiscale Averaging (DMA) of Turbulent Flow

    SciTech Connect (OSTI)

    Richard W. Johnson

    2012-09-01

    A new approach called dynamic multiscale averaging (DMA) for computing the effects of turbulent flow is described. The new method encompasses multiple applications of temporal and spatial averaging, that is, multiscale operations. Initially, a direct numerical simulation (DNS) is performed for a relatively short time; it is envisioned that this short time should be long enough to capture several fluctuating time periods of the smallest scales. The flow field variables are subject to running time averaging during the DNS. After the relatively short time, the time-averaged variables are volume averaged onto a coarser grid. Both time and volume averaging of the describing equations generate correlations in the averaged equations. These correlations are computed from the flow field and added as source terms to the computation on the next coarser mesh. They represent coupling between the two adjacent scales. Since they are computed directly from first principles, there is no modeling involved. However, there is approximation involved in the coupling correlations as the flow field has been computed for only a relatively short time. After the time and spatial averaging operations are applied at a given stage, new computations are performed on the next coarser mesh using a larger time step. The process continues until the coarsest scale needed is reached. New correlations are created for each averaging procedure. The number of averaging operations needed is expected to be problem dependent. The new DMA approach is applied to a relatively low Reynolds number flow in a square duct segment. Time-averaged stream-wise velocity and vorticity contours from the DMA approach appear to be very similar to a full DNS for a similar flow reported in the literature. Expected symmetry for the final results is produced for the DMA method. The results obtained indicate that DMA holds significant potential in being able to accurately compute turbulent flow without modeling for practical

  19. Flavor Physics Data from the Heavy Flavor Averaging Group (HFAG)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    The Heavy Flavor Averaging Group (HFAG) was established at the May 2002 Flavor Physics and CP Violation Conference in Philadelphia, and continues the LEP Heavy Flavor Steering Group's tradition of providing regular updates to the world averages of heavy flavor quantities. Data are provided by six subgroups that each focus on a different set of heavy flavor measurements: B lifetimes and oscillation parameters, Semi-leptonic B decays, Rare B decays, Unitarity triangle parameters, B decays to charm final states, and Charm Physics.

  20. Measurements of the reactor neutron power in absolute units

    SciTech Connect (OSTI)

    Lebedev, G. V.

    2015-12-15

    The neutron power of the reactor of the Yenisei space nuclear power plant is measured in absolute units using the modernized method of correlation analysis during the ground-based tests of the Yenisei prototypes. Results of the experiments are given. The desired result is obtained in a series of experiments carried out at the stage of the plant preparation for tests. The acceptability of experimental data is confirmed by the results of measuring the reactor neutron power in absolute units at the nominal level by the thermal balance during the life cycle tests of the ground prototypes.

  1. Glassy carbon as an absolute intensity calibration standard for small-angle scattering.

    SciTech Connect (OSTI)

    Zhang, F.; Ilavsky, J.; Long, G.; Allen, A.; Quintana, J.; Jemian, P.; NIST

    2010-05-01

    Absolute calibration of small-angle scattering (SAS) intensity data (measured in terms of the differential scattering cross section per unit sample volume per unit solid angle) is essential for many important aspects of quantitative SAS analysis, such as obtaining the number density, volume fraction, and specific surface area of the scatterers. It also enables scattering data from different instruments (light, X-ray, or neutron scattering) to be combined, and it can even be useful to detect the existence of artifacts in the experimental data. Different primary or secondary calibration methods are available. In the latter case, absolute intensity calibration requires a stable artifact with the necessary scattering profile. Glassy carbon has sometimes been selected as this intensity calibration standard. Here we review the spatial homogeneity and temporal stability of one type of commercially available glassy carbon that is being used as an intensity calibration standard at a number of SAS facilities. We demonstrate that glassy carbon is sufficiently homogeneous and stable during routine use to be relied upon as a suitable standard for absolute intensity calibration of SAS data.

  2. Polarized electron beams at milliampere average current

    SciTech Connect (OSTI)

    Poelker, Matthew

    2013-11-01

    This contribution describes some of the challenges associated with developing a polarized electron source capable of uninterrupted days-long operation at milliAmpere average beam current with polarization greater than 80%. Challenges will be presented in the context of assessing the required level of extrapolation beyond the performance of today's CEBAF polarized source operating at ~ 200 uA average current. Estimates of performance at higher current will be based on hours-long demonstrations at 1 and 4 mA. Particular attention will be paid to beam-related lifetime-limiting mechanisms, and strategies to construct a photogun that operate reliably at bias voltage > 350kV.

  3. Reynolds-Averaged Navier-Stokes

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reynolds-Averaged Navier-Stokes simulation of the heave performance of a two-body floating-point absorber wave energy system Yi-Hsiang Yu, Ye Li ⇑ National Wind Technology Center, National Renewable Energy Laboratory (NREL), Golden, CO 80401, USA a r t i c l e i n f o Article history: Received 7 September 2011 Received in revised form 5 August 2012 Accepted 9 October 2012 Available online 17 October 2012 Keywords: Wave energy conversion Heave Computational Fluid Dynamics Reynolds-averaged

  4. STEO January 2013 - average gasoline prices

    U.S. Energy Information Administration (EIA) Indexed Site

    drivers to see lower average gasoline prices in 2013 and 2014 U.S. retail gasoline prices are expected to decline over the next two years. The average pump price for regular unleaded gasoline was $3.63 a gallon during 2012. That is expected to fall to $3.44 this year and then drop to $3.34 in 2014, according to the new forecast from the U.S. Energy Information Administration. Expected lower crude oil prices.....which accounted for about two-thirds of the price of gasoline in 2012....will

  5. Fact #671: April 18, 2011 Average Truck Speeds | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    1: April 18, 2011 Average Truck Speeds Fact #671: April 18, 2011 Average Truck Speeds The Federal Highway Administration studies traffic volume and flow on major truck routes by tracking more than 500,000 trucks. The average speed of trucks on selected interstate highways is between 50 and 60 miles per hour (mph). The average operating speed of trucks is typically below 55 mph in major urban areas, border crossings, and in mountainous terrain. The difference in average speed between peak traffic

  6. HIGH AVERAGE POWER OPTICAL FEL AMPLIFIERS.

    SciTech Connect (OSTI)

    BEN-ZVI, ILAN, DAYRAN, D.; LITVINENKO, V.

    2005-08-21

    Historically, the first demonstration of the optical FEL was in an amplifier configuration at Stanford University [l]. There were other notable instances of amplifying a seed laser, such as the LLNL PALADIN amplifier [2] and the BNL ATF High-Gain Harmonic Generation FEL [3]. However, for the most part FELs are operated as oscillators or self amplified spontaneous emission devices. Yet, in wavelength regimes where a conventional laser seed can be used, the FEL can be used as an amplifier. One promising application is for very high average power generation, for instance FEL's with average power of 100 kW or more. The high electron beam power, high brightness and high efficiency that can be achieved with photoinjectors and superconducting Energy Recovery Linacs (ERL) combine well with the high-gain FEL amplifier to produce unprecedented average power FELs. This combination has a number of advantages. In particular, we show that for a given FEL power, an FEL amplifier can introduce lower energy spread in the beam as compared to a traditional oscillator. This properly gives the ERL based FEL amplifier a great wall-plug to optical power efficiency advantage. The optics for an amplifier is simple and compact. In addition to the general features of the high average power FEL amplifier, we will look at a 100 kW class FEL amplifier is being designed to operate on the 0.5 ampere Energy Recovery Linac which is under construction at Brookhaven National Laboratory's Collider-Accelerator Department.

  7. Introducing an Absolute Cavity Pyrgeometer for Improving the Atmospheric Longwave Irradiance Measurement (Presentation)

    SciTech Connect (OSTI)

    Reda, I.; Hansen, L.; Zeng, J.

    2012-08-01

    Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer (ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined by lowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the WISG. A total of 408 readings was collected over three different clear nights. The calculated irradiance measured by the ACP was 1.5 W/m2 lower than that measured by the two pyrgeometers that are traceable to WISG. Further development and characterization of the ACP might contribute to the effort of improving the uncertainty and traceability of WISG to SI.

  8. Absolute calibration for a broad range single shot electron spectrometer

    SciTech Connect (OSTI)

    Glinec, Y.; Faure, J.; Guemnie-Tafo, A.; Malka, V.; Monard, H.; Larbre, J. P.; De Waele, V.; Marignier, J. L.; Mostafavi, M.

    2006-10-15

    This article gives a detailed description of a single shot electron spectrometer which was used to characterize electron beams produced by laser-plasma interaction. Contrary to conventional electron sources, electron beams from laser-plasma accelerators can produce a broad range of energies. Therefore, diagnosing these electron spectra requires specific attention and experimental development. Here, we provide an absolute calibration of the Lanex Kodak Fine screen on a laser-triggered radio frequency picosecond electron accelerator. The efficiency of scintillating screens irradiated by electron beams has never been investigated so far. This absolute calibration is then compared to charge measurements from an integrating current transformer for quasimonoenergetic electron spectra from laser-plasma interaction.

  9. New applications for high average power beams

    SciTech Connect (OSTI)

    Neau, E.L.; Turman, B.N.; Patterson, E.L.

    1993-08-01

    The technology base formed by the development of high peak power simulators, laser drivers, FEL`s, and ICF drivers from the early 60`s through the late 80`s is being extended to high average power short-pulse machines with the capabilities of supporting new types of manufacturing processes and performing new roles in environmental cleanup applications. This paper discusses a process for identifying and developing possible commercial applications, specifically those requiring very high average power levels of hundreds of kilowatts to perhaps megawatts. The authors discuss specific technology requirements and give examples of application development efforts. The application development work is directed at areas that can possibly benefit from the high specific energies attainable with short pulse machines.

  10. Table 1. Real Average Transportation and Delivered Costs of Coal...

    U.S. Energy Information Administration (EIA) Indexed Site

    Real Average Transportation and Delivered Costs of Coal, By Year and Primary Transport Mode" "Year","Average Transportation Cost of Coal (Dollars per Ton)","Average Delivered Cost...

  11. A Green's function quantum average atom model

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Starrett, Charles Edward

    2015-05-21

    A quantum average atom model is reformulated using Green's functions. This allows integrals along the real energy axis to be deformed into the complex plane. The advantage being that sharp features such as resonances and bound states are broadened by a Lorentzian with a half-width chosen for numerical convenience. An implementation of this method therefore avoids numerically challenging resonance tracking and the search for weakly bound states, without changing the physical content or results of the model. A straightforward implementation results in up to a factor of 5 speed-up relative to an optimized orbital based code.

  12. Lens transmission measurement for an absolute radiation thermometer

    SciTech Connect (OSTI)

    Hao, X.; Yuan, Z.; Lu, X.

    2013-09-11

    The lens transmission for the National Institute of Metrology of China absolute radiation thermometer is measured by a hybrid method. The results of the lens transmission measurements are 99.002% and 86.792% for filter radiometers with center wavelengths 633 nm and 900 nm, respectively. These results, after correcting for diffraction factors and the size-of-source effect when the lens is incorporated within the radiometer, can be used for measurement of thermodynamic temperature. The expanded uncertainty of the lens transmission measurement system has been evaluated. It is 1.310{sup ?3} at 633 nm and 900 nm, respectively.

  13. Method of differential-phase/absolute-amplitude QAM

    DOE Patents [OSTI]

    Dimsdle, Jeffrey William

    2007-07-03

    A method of quadrature amplitude modulation involving encoding phase differentially and amplitude absolutely, allowing for a high data rate and spectral efficiency in data transmission and other communication applications, and allowing for amplitude scaling to facilitate data recovery; amplitude scale tracking to track-out rapid and severe scale variations and facilitate successful demodulation and data retrieval; 2.sup.N power carrier recovery; incoherent demodulation where coherent carrier recovery is not possible or practical due to signal degradation; coherent demodulation; multipath equalization to equalize frequency dependent multipath; and demodulation filtering.

  14. Method of differential-phase/absolute-amplitude QAM

    DOE Patents [OSTI]

    Dimsdle, Jeffrey William

    2007-10-02

    A method of quadrature amplitude modulation involving encoding phase differentially and amplitude absolutely, allowing for a high data rate and spectral efficiency in data transmission and other communication applications, and allowing for amplitude scaling to facilitate data recovery; amplitude scale tracking to track-out rapid and severe scale variations and facilitate successful demodulation and data retrieval; 2.sup.N power carrier recovery; incoherent demodulation where coherent carrier recovery is not possible or practical due to signal degradation; coherent demodulation; multipath equalization to equalize frequency dependent multipath; and demodulation filtering.

  15. Method of differential-phase/absolute-amplitude QAM

    DOE Patents [OSTI]

    Dimsdle, Jeffrey William

    2008-10-21

    A method of quadrature amplitude modulation involving encoding phase differentially and amplitude absolutely, allowing for a high data rate and spectral efficiency in data transmission and other communication applications, and allowing for amplitude scaling to facilitate data recovery; amplitude scale tracking to track-out rapid and severe scale variations and facilitate successful demodulation and data retrieval; 2.sup.N power carrier recovery; incoherent demodulation where coherent carrier recovery is not possible or practical due to signal degradation; coherent demodulation; multipath equalization to equalize frequency dependent multipath; and demodulation filtering.

  16. Method of differential-phase/absolute-amplitude QAM

    DOE Patents [OSTI]

    Dimsdle, Jeffrey William

    2009-09-01

    A method of quadrature amplitude modulation involving encoding phase differentially and amplitude absolutely, allowing for a high data rate and spectral efficiency in data transmission and other communication applications, and allowing for amplitude scaling to facilitate data recovery; amplitude scale tracking to track-out rapid and severe scale variations and facilitate successful demodulation and data retrieval; 2.sup.N power carrier recovery; incoherent demodulation where coherent carrier recovery is not possible or practical due to signal degradation; coherent demodulation; multipath equalization to equalize frequency dependent multipath; and demodulation filtering.

  17. Method of differential-phase/absolute-amplitude QAM

    DOE Patents [OSTI]

    Dimsdle, Jeffrey William

    2007-07-17

    A method of quadrature amplitude modulation involving encoding phase differentially and amplitude absolutely, allowing for a high data rate and spectral efficiency in data transmission and other communication applications, and allowing for amplitude scaling to facilitate data recovery; amplitude scale tracking to track-out rapid and severe scale variations and facilitate successful demodulation and data retrieval; 2.sup.N power carrier recovery; incoherent demodulation where coherent carrier recovery is not possible or practical due to signal degradation; coherent demodulation; multipath equalization to equalize frequency dependent multipath; and demodulation filtering.

  18. AN ACCURATE NEW METHOD OF CALCULATING ABSOLUTE MAGNITUDES AND K-CORRECTIONS APPLIED TO THE SLOAN FILTER SET

    SciTech Connect (OSTI)

    Beare, Richard; Brown, Michael J. I.; Pimbblet, Kevin

    2014-12-20

    We describe an accurate new method for determining absolute magnitudes, and hence also K-corrections, that is simpler than most previous methods, being based on a quadratic function of just one suitably chosen observed color. The method relies on the extensive and accurate new set of 129 empirical galaxy template spectral energy distributions from Brown et al. A key advantage of our method is that we can reliably estimate random errors in computed absolute magnitudes due to galaxy diversity, photometric error and redshift error. We derive K-corrections for the five Sloan Digital Sky Survey filters and provide parameter tables for use by the astronomical community. Using the New York Value-Added Galaxy Catalog, we compare our K-corrections with those from kcorrect. Our K-corrections produce absolute magnitudes that are generally in good agreement with kcorrect. Absolute griz magnitudes differ by less than 0.02 mag and those in the u band by ∼0.04 mag. The evolution of rest-frame colors as a function of redshift is better behaved using our method, with relatively few galaxies being assigned anomalously red colors and a tight red sequence being observed across the whole 0.0 < z < 0.5 redshift range.

  19. THE ABSOLUTE CALIBRATION OF THE EUV IMAGING SPECTROMETER ON HINODE

    SciTech Connect (OSTI)

    Warren, Harry P.; Ugarte-Urra, Ignacio; Landi, Enrico

    2014-07-01

    We investigate the absolute calibration of the EUV Imaging Spectrometer (EIS) on Hinode by comparing EIS full-disk mosaics with irradiance observations from the EUV Variability Experiment on the Solar Dynamics Observatory. We also use extended observations of the quiet corona above the limb combined with a simple differential emission measure model to establish new effective area curves that incorporate information from the most recent atomic physics calculations. We find that changes to the EIS instrument sensitivity are a complex function of both time and wavelength. We find that the sensitivity is decaying exponentially with time and that the decay constants vary with wavelength. The EIS short wavelength channel shows significantly longer decay times than the long wavelength channel.

  20. Method and apparatus for making absolute range measurements

    DOE Patents [OSTI]

    Earl, Dennis D.; Allison, Stephen W.; Cates, Michael R.; Sanders, Alvin J.

    2002-09-24

    This invention relates to a method and apparatus for making absolute distance or ranging measurements using Fresnel diffraction. The invention employs a source of electromagnetic radiation having a known wavelength or wavelength distribution, which sends a beam of electromagnetic radiation through a screen at least partially opaque at the wavelength. The screen has an aperture sized so as to produce a Fresnel diffraction pattern. A portion of the beam travels through the aperture to a detector spaced some distance from the screen. The detector detects the central intensity of the beam as well as a set of intensities displaced from a center of the aperture. The distance from the source to the target can then be calculated based upon the known wavelength, aperture radius, and beam intensity.

  1. Absolute properties of the triple star HP Aurigae

    SciTech Connect (OSTI)

    Lacy, Claud H. Sandberg; Burks, Charles L.; Torres, Guillermo; Wolf, Marek E-mail: clburks@email.uark.edu E-mail: wolf@cesnet.cz

    2014-01-01

    New photometric, spectroscopic, and eclipse timing observations of the eclipsing binary star HP Aur allow for very accurate orbital determinations, even in the presence of a third body and transient starspot activity. The eclipsing binary masses are determined to an accuracy of ±0.4% and the radii to ±0.6%. The masses are 0.9543 ± 0.0041 and 0.8094 ± 0.0036 solar masses, and the radii are 1.0278 ± 0.0042 and 0.7758 ± 0.0034 solar radii, respectively. The orbital period in the outer orbit is accurately determined for the first time: 4.332 ± 0.011 yr. A comparison with current theories of stellar evolution shows that the components' absolute properties can be well-matched by the current models at an age of about 7 billion years.

  2. Fact #849: December 1, 2014 Midsize Hybrid Cars Averaged 51% Better Fuel

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Economy than Midsize Non-Hybrid Cars in 2014 | Department of Energy 9: December 1, 2014 Midsize Hybrid Cars Averaged 51% Better Fuel Economy than Midsize Non-Hybrid Cars in 2014 Fact #849: December 1, 2014 Midsize Hybrid Cars Averaged 51% Better Fuel Economy than Midsize Non-Hybrid Cars in 2014 For the 2014 model year, midsize hybrid cars averaged 43.4 miles per gallon (mpg) while midsize non-hybrid cars averaged 28.7 mpg; the difference between the two has narrowed due to the rising average

  3. Annual average efficiency of a solar thermochemical reactor....

    Office of Scientific and Technical Information (OSTI)

    Annual average efficiency of a solar thermochemical reactor. Citation Details In-Document Search Title: Annual average efficiency of a solar thermochemical reactor. Abstract not ...

  4. ARM: Temperature Profiles from Raman Lidar at 60-min averaging...

    Office of Scientific and Technical Information (OSTI)

    Citation Details In-Document Search Title: ARM: Temperature Profiles from Raman Lidar at 60-min averaging interval Temperature Profiles from Raman Lidar at 60-min averaging ...

  5. ARM: Temperature Profiles from Raman Lidar at 10-min averaging...

    Office of Scientific and Technical Information (OSTI)

    Temperature Profiles from Raman Lidar at 10-min averaging interval Title: ARM: Temperature Profiles from Raman Lidar at 10-min averaging interval Temperature Profiles from Raman ...

  6. ARM: AOS Wet Nephelometer 1 Minute Averages (Dataset) | Data...

    Office of Scientific and Technical Information (OSTI)

    Title: ARM: AOS Wet Nephelometer 1 Minute Averages AOS Wet Nephelometer 1 Minute Averages Authors: Scott Smith ; Cynthia Salwen ; Janek Uin ; Gunnar Senum ; Stephen Springston ; ...

  7. ARM: AOS Dry Nephelometer 1 Minute Averages (Dataset) | Data...

    Office of Scientific and Technical Information (OSTI)

    Title: ARM: AOS Dry Nephelometer 1 Minute Averages AOS Dry Nephelometer 1 Minute Averages Authors: Scott Smith ; Cynthia Salwen ; Janek Uin ; Gunnar Senum ; Stephen Springston ; ...

  8. High Average Brightness Photocathode Development for FEL Applications...

    Office of Scientific and Technical Information (OSTI)

    Conference: High Average Brightness Photocathode Development for FEL Applications Citation Details In-Document Search Title: High Average Brightness Photocathode Development for...

  9. THE ABSOLUTE MAGNITUDE OF RRc VARIABLES FROM STATISTICAL PARALLAX

    SciTech Connect (OSTI)

    Kollmeier, Juna A.; Burns, Christopher R.; Thompson, Ian B.; Preston, George W.; Crane, Jeffrey D.; Madore, Barry F.; Morrell, Nidia; Prieto, José L.; Shectman, Stephen; Simon, Joshua D.; Villanueva, Edward; Szczygieł, Dorota M.; Gould, Andrew; Sneden, Christopher; Dong, Subo

    2013-09-20

    We present the first definitive measurement of the absolute magnitude of RR Lyrae c-type variable stars (RRc) determined purely from statistical parallax. We use a sample of 242 RRc variables selected from the All Sky Automated Survey for which high-quality light curves, photometry, and proper motions are available. We obtain high-resolution echelle spectra for these objects to determine radial velocities and abundances as part of the Carnegie RR Lyrae Survey. We find that M{sub V,RRc} = 0.59 ± 0.10 at a mean metallicity of [Fe/H] = –1.59. This is to be compared with previous estimates for RRab stars (M{sub V,RRab} = 0.76 ± 0.12) and the only direct measurement of an RRc absolute magnitude (RZ Cephei, M{sub V,RRc} = 0.27 ± 0.17). We find the bulk velocity of the halo relative to the Sun to be (W{sub π}, W{sub θ}, W{sub z} ) = (12.0, –209.9, 3.0) km s{sup –1} in the radial, rotational, and vertical directions with dispersions (σ{sub W{sub π}},σ{sub W{sub θ}},σ{sub W{sub z}}) = (150.4, 106.1, 96.0) km s{sup -1}. For the disk, we find (W{sub π}, W{sub θ}, W{sub z} ) = (13.0, –42.0, –27.3) km s{sup –1} relative to the Sun with dispersions (σ{sub W{sub π}},σ{sub W{sub θ}},σ{sub W{sub z}}) = (67.7,59.2,54.9) km s{sup -1}. Finally, as a byproduct of our statistical framework, we are able to demonstrate that UCAC2 proper-motion errors are significantly overestimated as verified by UCAC4.

  10. INTERPRETATION OF THE ARCADE 2 ABSOLUTE SKY BRIGHTNESS MEASUREMENT

    SciTech Connect (OSTI)

    Seiffert, M.; Levin, S. M.; Fixsen, D. J.; Kogut, A.; Wollack, E.; Limon, M.; Lubin, P. M.; Mirel, P.; Singal, J.; Villela, T.; Wuensche, C. A.

    2011-06-10

    We use absolutely calibrated data between 3 and 90 GHz from the 2006 balloon flight of the ARCADE 2 instrument, along with previous measurements at other frequencies, to constrain models of extragalactic emission. Such emission is a combination of the cosmic microwave background (CMB) monopole, Galactic foreground emission, the integrated contribution of radio emission from external galaxies, any spectral distortions present in the CMB, and any other extragalactic source. After removal of estimates of foreground emission from our own Galaxy, and an estimated contribution of external galaxies, we present fits to a combination of the flat-spectrum CMB and potential spectral distortions in the CMB. We find 2{sigma} upper limits to CMB spectral distortions of {mu} < 6 x 10{sup -4} and |Y{sub ff}| < 1 x 10{sup -4}. We also find a significant detection of a residual signal beyond that, which can be explained by the CMB plus the integrated radio emission from galaxies estimated from existing surveys. This residual signal may be due to an underestimated galactic foreground contribution, an unaccounted for contribution of a background of radio sources, or some combination of both. The residual signal is consistent with emission in the form of a power law with amplitude 18.4 {+-} 2.1 K at 0.31 GHz and a spectral index of -2.57 {+-} 0.05.

  11. Method and apparatus for making absolute range measurements

    DOE Patents [OSTI]

    Allison, Stephen W. (Knoxville, TN); Cates, Michael R. (Oak Ridge, TN); Key, William S. (Knoxville, TN); Sanders, Alvin J. (Knoxville, TN); Earl, Dennis D. (Knoxville, TN)

    1999-01-01

    This invention relates to a method and apparatus for making absolute distance or ranging measurements using Fresnel diffraction. The invention employs a source of electromagnetic radiation having a known wavelength or wavelength distribution, which sends a beam of electromagnetic radiation through an object which causes it to be split (hereinafter referred to as a "beamsplitter"), and then to a target. The beam is reflected from the target onto a screen containing an aperture spaced a known distance from the beamsplitter. The aperture is sized so as to produce a Fresnel diffraction pattern. A portion of the beam travels through the aperture to a detector, spaced a known distance from the screen. The detector detects the central intensity of the beam. The distance from the object which causes the beam to be split to the target can then be calculated based upon the known wavelength, aperture radius, beam intensity, and distance from the detector to the screen. Several apparatus embodiments are disclosed for practicing the method embodiments of the present invention.

  12. Method and apparatus for making absolute range measurements

    DOE Patents [OSTI]

    Allison, S.W.; Cates, M.R.; Key, W.S.; Sanders, A.J.; Earl, D.D.

    1999-06-22

    This invention relates to a method and apparatus for making absolute distance or ranging measurements using Fresnel diffraction. The invention employs a source of electromagnetic radiation having a known wavelength or wavelength distribution, which sends a beam of electromagnetic radiation through an object which causes it to be split (hereinafter referred to as a beam splitter''), and then to a target. The beam is reflected from the target onto a screen containing an aperture spaced a known distance from the beam splitter. The aperture is sized so as to produce a Fresnel diffraction pattern. A portion of the beam travels through the aperture to a detector, spaced a known distance from the screen. The detector detects the central intensity of the beam. The distance from the object which causes the beam to be split to the target can then be calculated based upon the known wavelength, aperture radius, beam intensity, and distance from the detector to the screen. Several apparatus embodiments are disclosed for practicing the method embodiments of the present invention. 9 figs.

  13. Fact #889: September 7, 2015 Average Diesel Price Lower than...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    9: September 7, 2015 Average Diesel Price Lower than Gasoline for the First Time in Six Years Fact 889: September 7, 2015 Average Diesel Price Lower than Gasoline for the First ...

  14. Fact #849: December 1, 2014 Midsize Hybrid Cars Averaged 51%...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    9: December 1, 2014 Midsize Hybrid Cars Averaged 51% Better Fuel Economy than Midsize Non-Hybrid Cars in 2014 Fact 849: December 1, 2014 Midsize Hybrid Cars Averaged 51% Better ...

  15. Fact #835: August 25, 2014 Average Annual Gasoline Pump Price...

    Broader source: Energy.gov (indexed) [DOE]

    35: Average Annual Gasoline Pump Price, 1929-2013 fotw835web.xlsx (21.31 KB) More Documents & Publications Fact 915: March 7, 2016 Average Historical Annual Gasoline Pump Price, ...

  16. Fact #693: September 19, 2011 Average Vehicle Footprint for Cars...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    It is calculated as the product of the wheelbase and the average track width of the vehicle. The upcoming Corporate Average Fuel Economy (CAFE) Standards have fuel economy targets ...

  17. Fact #870: April 27, 2015 Corporate Average Fuel Economy Progress...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    0: April 27, 2015 Corporate Average Fuel Economy Progress, 1978-2014 - Dataset Fact 870: April 27, 2015 Corporate Average Fuel Economy Progress, 1978-2014 - Dataset Excel file and ...

  18. Comparison of absolute spectral irradiance responsivity measurement techniques using wavelength-tunable lasers

    SciTech Connect (OSTI)

    Ahtee, Ville; Brown, Steven W.; Larason, Thomas C.; Lykke, Keith R.; Ikonen, Erkki; Noorma, Mart

    2007-07-10

    Independent methods for measuring the absolute spectral irradiance responsivity of detectors have been compared between the calibration facilities at two national metrology institutes, the Helsinki University of Technology (TKK), Finland, and the National Institute of Standards and Technology (NIST). The emphasis is on the comparison of two different techniques for generating a uniform irradiance at a reference plane using wavelength-tunable lasers. At TKK's Laser Scanning Facility (LSF) the irradiance is generated by raster scanning a single collimated laser beam, while at the NIST facility for Spectral Irradiance and Radiance Responsivity Calibrations with Uniform Sources (SIRCUS), lasers are introduced into integrating spheres to generate a uniform irradiance at a reference plane. The laser-based irradiance responsivity results are compared to a traditional lamp-monochromator-based irradiance responsivity calibration obtained at the NIST Spectral Comparator Facility (SCF). A narrowband filter radiometer with a24 nm bandwidth and an effective band-center wavelength of 801 nm was used as the artifact. The results of the comparison between the different facilities, reported for the first time in the near-infrared wavelength range, demonstrate agreement at the uncertainty level of less than 0.1%. This result has significant implications in radiation thermometry and in photometry as well as in radiometry.

  19. High Average Brightness Photocathode Development for FEL Applications...

    Office of Scientific and Technical Information (OSTI)

    Title: High Average Brightness Photocathode Development for FEL Applications Authors: Rao T. ; Ben-Zvi I. ; Skarita, J. ; Wang, E. Publication Date: 2013-08-26 OSTI Identifier: ...

  20. Turning Bayesian model averaging into Bayesian model combination...

    Office of Scientific and Technical Information (OSTI)

    Title: Turning Bayesian model averaging into Bayesian model combination Authors: Carroll, James 1 ; Monteith, Kristine 2 ; Seppi, Kevin 2 ; Martinez, Tony 2 + Show Author ...

  1. "Table 2. Real Average Annual Coal Transportation Costs, By Primary...

    U.S. Energy Information Administration (EIA) Indexed Site

    Real Average Annual Coal Transportation Costs, By Primary Transport Mode and Supply Region" "(2013 dollars per ton)" "Coal Supply Region",2008,2009,2010,2011,2012,2013 "Railroad"...

  2. Table 14a. Average Electricity Prices, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    a. Average Electricity Prices, Projected vs. Actual" "Projected Price in Constant Dollars" " (constant dollars, cents per kilowatt-hour in ""dollar year"" specific to each AEO)" ...

  3. Fact #803: November 11, 2013 Average Number of Transmission Gears...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Average Number of Gears for New Light Vehicles, Model Years 1979-2012 Model Year Average Number of Gears 1979 3.3 1980 3.5 1981 3.5 1982 3.6 1983 3.7 1984 3.7 1985 3.8 1986 3.8 ...

  4. High average power scaling of optical parametric amplification through cascaded difference-frequency generators

    DOE Patents [OSTI]

    Jovanovic, Igor; Comaskey, Brian J.

    2004-09-14

    A first pump pulse and a signal pulse are injected into a first optical parametric amplifier. This produces a first amplified signal pulse. At least one additional pump pulse and the first amplified signal pulse are injected into at least one additional optical parametric amplifier producing an increased power coherent optical pulse.

  5. Femtosecond frequency comb measurement of absolute frequencies and hyperfine coupling constants in cesium vapor

    SciTech Connect (OSTI)

    Stalnaker, Jason E.; Mbele, Vela; Gerginov, Vladislav; Fortier, Tara M.; Diddams, Scott A.; Hollberg, Leo; Tanner, Carol E.

    2010-04-15

    We report measurements of absolute transition frequencies and hyperfine coupling constants for the 8S{sub 1/2}, 9S{sub 1/2}, 7D{sub 3/2}, and 7D{sub 5/2} states in {sup 133}Cs vapor. The stepwise excitation through either the 6P{sub 1/2} or 6P{sub 3/2} intermediate state is performed directly with broadband laser light from a stabilized femtosecond laser optical-frequency comb. The laser beam is split, counterpropagated, and focused into a room-temperature Cs vapor cell. The repetition rate of the frequency comb is scanned and we detect the fluorescence on the 7P{sub 1/2,3/2{yields}}6S{sub 1/2} branches of the decay of the excited states. The excitations to the different states are isolated by the introduction of narrow-bandwidth interference filters in the laser beam paths. Using a nonlinear least-squares method we find measurements of transition frequencies and hyperfine coupling constants that are in agreement with other recent measurements for the 8S state and provide improvement by 2 orders of magnitude over previously published results for the 9S and 7D states.

  6. In-Flight Measurement of the Absolute Energy Scale of the Fermi Large Area Telescope

    SciTech Connect (OSTI)

    Ackermann, M.; Ajello, M.; Allafort, A.; Atwood, W.B.; Axelsson, M.; Baldini, L.; Barbiellini, G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Berenji, B.; Bloom, E.D.; Bonamente, E.; Borgland, A.W.; Bouvier, A.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.; Buehler, R.; Buson, S.; /more authors..

    2012-09-20

    The Large Area Telescope (LAT) on-board the Fermi Gamma-ray Space Telescope is a pair-conversion telescope designed to survey the gamma-ray sky from 20 MeV to several hundreds of GeV. In this energy band there are no astronomical sources with sufficiently well known and sharp spectral features to allow an absolute calibration of the LAT energy scale. However, the geomagnetic cutoff in the cosmic ray electron-plus-positron (CRE) spectrum in low Earth orbit does provide such a spectral feature. The energy and spectral shape of this cutoff can be calculated with the aid of a numerical code tracing charged particles in the Earth's magnetic field. By comparing the cutoff value with that measured by the LAT in different geomagnetic positions, we have obtained several calibration points between {approx}6 and {approx}13 GeV with an estimated uncertainty of {approx}2%. An energy calibration with such high accuracy reduces the systematic uncertainty in LAT measurements of, for example, the spectral cutoff in the emission from gamma ray pulsars.

  7. Fact #870: April 27, 2015 Corporate Average Fuel Economy Progress,

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    1978-2014 - Dataset | Department of Energy 0: April 27, 2015 Corporate Average Fuel Economy Progress, 1978-2014 - Dataset Fact #870: April 27, 2015 Corporate Average Fuel Economy Progress, 1978-2014 - Dataset Excel file and dataset for Corporate Average Fuel Economy Progress, 1978-2014 fotw#870_web.xlsx (17.92 KB) More Documents & Publications Reactor Pressure Vessel Task of Light Water Reactor Sustainability Program: Milestone Report on Materials and Machining of Specimens for the ATR-2

  8. U.S. Refiner Sales to End Users (Average) Prices

    U.S. Energy Information Administration (EIA) Indexed Site

    Sales Type: Sales to End Users, Average Through Retail Outlets Sales for Resale, Average DTW Rack Bulk Download Series History Download Series History Definitions, Sources & Notes Definitions, Sources & Notes Show Data By: Formulation/ Grade Sales Type Jan-16 Feb-16 Mar-16 Apr-16 May-16 Jun-16 View History Conventional, Average 1.346 1.209 1.450 1.617 1.790 1.894 1994-2016 Conventional Regular 1.305 1.167 1.412 1.576 1.749 1.854 1994-2016 Conventional Midgrade 1.524 1.376 1.601 1.781

  9. Does anyone have access to 2012 average residential rates by...

    Open Energy Info (EERE)

    Does anyone have access to 2012 average residential rates by utility company? I'm seeing an inconsistency between the OpenEI website and EIA 861 data set. Home > Groups > Utility...

  10. Fact #915: March 7, 2016 Average Historical Annual Gasoline Pump...

    Broader source: Energy.gov (indexed) [DOE]

    Average Historical Annual Gasoline Pump Price, 1929-2015 fotw915web.xlsx (24.76 KB) More Documents & Publications Fact 888: August 31, 2015 Historical Gas Prices - Dataset Fact ...

  11. Fact #624: May 24, 2010 Corporate Average Fuel Economy Standards...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    The final rule for the Corporate Average Fuel Economy (CAFE) Standards was published in ... The CAFE levels that must be met by the fleet of each manufacturer will be determined by ...

  12. Table 14b. Average Electricity Prices, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    b. Average Electricity Prices, Projected vs. Actual" "Projected Price in Nominal Dollars" " (nominal dollars, cents per kilowatt-hour)" ,1993,1994,1995,1996,1997,1998,1999,2000,200...

  13. Table 14b. Average Electricity Prices, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    b. Average Electricity Prices, Projected vs. Actual Projected Price in Nominal Dollars (nominal dollars, cents per kilowatt-hour) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 ...

  14. Averaged null energy condition violation in a conformally flat spacetime

    SciTech Connect (OSTI)

    Urban, Douglas; Olum, Ken D.

    2010-01-15

    We show that the averaged null energy condition can be violated by a conformally coupled scalar field in a conformally flat spacetime in 3+1 dimensions. The violation is dependent on the quantum state and can be made as large as desired. It does not arise from the presence of anomalies, although anomalous violations are also possible. Since all geodesics in conformally flat spacetimes are achronal, the achronal averaged null energy condition is likewise violated.

  15. Precision laser surveying instrument using atmospheric turbulence compensation by determining the absolute displacement between two laser beam components

    DOE Patents [OSTI]

    Veligdan, James T.

    1993-01-01

    Atmospheric effects on sighting measurements are compensated for by adjusting any sighting measurements using a correction factor that does not depend on atmospheric state conditions such as temperature, pressure, density or turbulence. The correction factor is accurately determined using a precisely measured physical separation between two color components of a light beam (or beams) that has been generated using either a two-color laser or two lasers that project different colored beams. The physical separation is precisely measured by fixing the position of a short beam pulse and measuring the physical separation between the two fixed-in-position components of the beam. This precisely measured physical separation is then used in a relationship that includes the indexes of refraction for each of the two colors of the laser beam in the atmosphere through which the beam is projected, thereby to determine the absolute displacement of one wavelength component of the laser beam from a straight line of sight for that projected component of the beam. This absolute displacement is useful to correct optical measurements, such as those developed in surveying measurements that are made in a test area that includes the same dispersion effects of the atmosphere on the optical measurements. The means and method of the invention are suitable for use with either single-ended systems or a double-ended systems.

  16. Dynamic frequency-domain interferometer for absolute distance measurements with high resolution

    SciTech Connect (OSTI)

    Weng, Jidong; Liu, Shenggang; Ma, Heli; Tao, Tianjiong; Wang, Xiang; Liu, Cangli; Tan, Hua

    2014-11-15

    A unique dynamic frequency-domain interferometer for absolute distance measurement has been developed recently. This paper presents the working principle of the new interferometric system, which uses a photonic crystal fiber to transmit the wide-spectrum light beams and a high-speed streak camera or frame camera to record the interference stripes. Preliminary measurements of harmonic vibrations of a speaker, driven by a radio, and the changes in the tip clearance of a rotating gear wheel show that this new type of interferometer has the ability to perform absolute distance measurements both with high time- and distance-resolution.

  17. High average power scaleable thin-disk laser

    DOE Patents [OSTI]

    Beach, Raymond J.; Honea, Eric C.; Bibeau, Camille; Payne, Stephen A.; Powell, Howard; Krupke, William F.; Sutton, Steven B.

    2002-01-01

    Using a thin disk laser gain element with an undoped cap layer enables the scaling of lasers to extremely high average output power values. Ordinarily, the power scaling of such thin disk lasers is limited by the deleterious effects of amplified spontaneous emission. By using an undoped cap layer diffusion bonded to the thin disk, the onset of amplified spontaneous emission does not occur as readily as if no cap layer is used, and much larger transverse thin disks can be effectively used as laser gain elements. This invention can be used as a high average power laser for material processing applications as well as for weapon and air defense applications.

  18. Turning Bayesian model averaging into Bayesian model combination

    Office of Scientific and Technical Information (OSTI)

    (Conference) | SciTech Connect Turning Bayesian model averaging into Bayesian model combination Citation Details In-Document Search Title: Turning Bayesian model averaging into Bayesian model combination Authors: Carroll, James [1] ; Monteith, Kristine [2] ; Seppi, Kevin [2] ; Martinez, Tony [2] + Show Author Affiliations Los Alamos National Laboratory BYU Publication Date: 2011-07-28 OSTI Identifier: 1084524 Report Number(s): LA-UR-11-04419; LA-UR-11-4419 DOE Contract Number: AC52-06NA25396

  19. U.S. average gasoline price up slightly

    U.S. Energy Information Administration (EIA) Indexed Site

    U.S. average gasoline price up slightly The U.S. average retail price for regular gasoline rose slightly to $3.65 a gallon on Monday. That's up a tenth of a penny from a week ago, based on the weekly price survey by the U.S. Energy Information Administration. Pump prices were highest in the West Coast region at 3.89 a gallon, down 4.4 cents from a week ago. Prices were lowest in the Gulf Coast States at 3.34 a gallon, down 2.6 cents. Jonathan Cogan for EIA,

  20. Virginia Average Price of Natural Gas Delivered to Residential and

    U.S. Energy Information Administration (EIA) Indexed Site

    Commercial Consumers by Local Distribution and Market 9.45 8.76 10.20 10.63 12.69 15.51 1989-2016 Commercial Average Price 6.88 6.67 7.18 6.65 7.24 7.22

  1. Speckle averaging system for laser raster-scan image projection

    DOE Patents [OSTI]

    Tiszauer, Detlev H.; Hackel, Lloyd A.

    1998-03-17

    The viewers' perception of laser speckle in a laser-scanned image projection system is modified or eliminated by the addition of an optical deflection system that effectively presents a new speckle realization at each point on the viewing screen to each viewer for every scan across the field. The speckle averaging is accomplished without introduction of spurious imaging artifacts.

  2. Maryland Average Price of Natural Gas Delivered to Residential...

    Gasoline and Diesel Fuel Update (EIA)

    8.35 18.44 19.08 19.39 13.51 12.72 1989-2015 Commercial Average Price 11.74 10.98 11.61 11.11 9.98 9.56...

  3. Michigan Average Price of Natural Gas Delivered to Residential...

    U.S. Energy Information Administration (EIA) Indexed Site

    2.50 13.65 13.52 13.21 8.93 7.84 1989-2015 Commercial Average Price 8.91 9.31 9.17 9.05 7.46 6.75...

  4. Parity-violating anomalies and the stationarity of stochastic averages

    SciTech Connect (OSTI)

    Reuter, M.

    1988-01-15

    Within the framework of stochastic quantization the parity-violating anomalies in odd space-time dimensions are derived from the asymptotic stationarity of the stochastic average of a certain fermion bilinear. Contrary to earlier attempts, this method yields the correct anomalies for both massive and massless fermions.

  5. Pennsylvania Average Price of Natural Gas Delivered to Residential and

    U.S. Energy Information Administration (EIA) Indexed Site

    Commercial Consumers by Local Distribution and Ma 8.75 8.64 9.51 9.91 11.30 15.62 1989-2016 Commercial Average Price 7.19 7.44 8.21 8.12 8.74 10.69

  6. Speckle averaging system for laser raster-scan image projection

    DOE Patents [OSTI]

    Tiszauer, D.H.; Hackel, L.A.

    1998-03-17

    The viewers` perception of laser speckle in a laser-scanned image projection system is modified or eliminated by the addition of an optical deflection system that effectively presents a new speckle realization at each point on the viewing screen to each viewer for every scan across the field. The speckle averaging is accomplished without introduction of spurious imaging artifacts. 5 figs.

  7. Florida Average Price of Natural Gas Delivered to Residential and

    U.S. Energy Information Administration (EIA) Indexed Site

    Commercial Consumers by Local Distribution and Markete 6.78 16.00 17.06 17.83 20.52 22.40 1989-2016 Commercial Average Price 10.70 10.62 10.50 10.29 10.16 10.38

  8. Georgia Average Price of Natural Gas Delivered to Residential and

    U.S. Energy Information Administration (EIA) Indexed Site

    Commercial Consumers by Local Distribution and Markete 0.79 10.94 13.01 16.48 20.53 24.74 1989-2016 Commercial Average Price 6.57 7.05 7.42 7.98 8.22 8.53

  9. Maryland Average Price of Natural Gas Delivered to Residential...

    U.S. Energy Information Administration (EIA) Indexed Site

    Local Distribution Companies 12.20 2006-2010 Marketers 13.51 2006-2010 Percent Sold by Local Distribution Companies 81.7 2006-2010 Commercial Average Price 9.87 10.29 10.00 10.06 ...

  10. Florida Average Price of Natural Gas Delivered to Residential...

    U.S. Energy Information Administration (EIA) Indexed Site

    Local Distribution Companies 17.85 2006-2010 Marketers 19.44 2006-2010 Percent Sold by Local Distribution Companies 97.9 2006-2010 Commercial Average Price 10.60 11.14 10.41 10.87 ...

  11. New Jersey Average Price of Natural Gas Delivered to Residential...

    U.S. Energy Information Administration (EIA) Indexed Site

    Local Distribution Companies 12.77 2006-2010 Marketers 14.87 2006-2010 Percent Sold by Local Distribution Companies 96.6 2006-2010 Commercial Average Price 10.11 9.51 8.50 9.55 ...

  12. Michigan Average Price of Natural Gas Delivered to Residential...

    U.S. Energy Information Administration (EIA) Indexed Site

    Commercial Average Price 8.95 9.14 8.35 7.82 8.28 7.49 1967-2015 Local Distribution Companies 10.00 2006-2010 Marketers 7.61 2006-2010 Percent Sold by Local Distribution Companies ...

  13. Virginia Average Price of Natural Gas Delivered to Residential...

    U.S. Energy Information Administration (EIA) Indexed Site

    Local Distribution Companies 12.64 2006-2010 Marketers 13.64 2006-2010 Percent Sold by Local Distribution Companies 90.9 2006-2010 Commercial Average Price 9.55 9.69 8.77 8.83 9.17 ...

  14. Pennsylvania Average Price of Natural Gas Delivered to Residential...

    U.S. Energy Information Administration (EIA) Indexed Site

    Local Distribution Companies 12.82 2006-2010 Marketers 13.78 2006-2010 Percent Sold by Local Distribution Companies 91.2 2006-2010 Commercial Average Price 10.47 10.42 10.24 10.11 ...

  15. District of Columbia Average Price of Natural Gas Delivered to...

    U.S. Energy Information Administration (EIA) Indexed Site

    Average Price 12.26 12.24 11.19 11.64 12.18 11.55 1980-2015 Local Distribution Companies 12.99 2006-2010 Marketers 12.12 2006-2010 Percent Sold by Local Distribution Companies 16.4 ...

  16. Characterizing absolute piezoelectric microelectromechanical system displacement using an atomic force microscope

    SciTech Connect (OSTI)

    Evans, J. Chapman, S.

    2014-08-14

    Piezoresponse Force Microscopy (PFM) is a popular tool for the study of ferroelectric and piezoelectric materials at the nanometer level. Progress in the development of piezoelectric MEMS fabrication is highlighting the need to characterize absolute displacement at the nanometer and Ångstrom scales, something Atomic Force Microscopy (AFM) might do but PFM cannot. Absolute displacement is measured by executing a polarization measurement of the ferroelectric or piezoelectric capacitor in question while monitoring the absolute vertical position of the sample surface with a stationary AFM cantilever. Two issues dominate the execution and precision of such a measurement: (1) the small amplitude of the electrical signal from the AFM at the Ångstrom level and (2) calibration of the AFM. The authors have developed a calibration routine and test technique for mitigating the two issues, making it possible to use an atomic force microscope to measure both the movement of a capacitor surface as well as the motion of a micro-machine structure actuated by that capacitor. The theory, procedures, pitfalls, and results of using an AFM for absolute piezoelectric measurement are provided.

  17. Absolutely continuous spectrum implies ballistic transport for quantum particles in a random potential on tree graphs

    SciTech Connect (OSTI)

    Aizenman, Michael; Warzel, Simone

    2012-09-15

    We discuss the dynamical implications of the recent proof that for a quantum particle in a random potential on a regular tree graph absolutely continuous (ac) spectrum occurs non-perturbatively through rare fluctuation-enabled resonances. The main result is spelled in the title.

  18. Radio frequency cavity analysis, measurement, and calibration of absolute Dee voltage for K-500 superconducting cyclotron at VECC, Kolkata

    SciTech Connect (OSTI)

    Som, Sumit; Seth, Sudeshna; Mandal, Aditya; Paul, Saikat; Duttagupta, Anjan

    2013-02-15

    Variable Energy Cyclotron Centre has commissioned a K-500 superconducting cyclotron for various types of nuclear physics experiments. The 3-phase radio-frequency system of superconducting cyclotron has been developed in the frequency range 9-27 MHz with amplitude and phase stability of 100 ppm and {+-}0.2{sup 0}, respectively. The analysis of the RF cavity has been carried out using 3D Computer Simulation Technology (CST) Microwave Studio code and various RF parameters and accelerating voltages ('Dee' voltage) are calculated from simulation. During the RF system commissioning, measurement of different RF parameters has been done and absolute Dee voltage has been calibrated using a CdTe X-ray detector along with its accessories and known X-ray source. The present paper discusses about the measured data and the simulation result.

  19. UNBIASED MOMENT-RATE SPECTRA AND ABSOLUTE SITE EFFECTS IN THE KACHCHH BASIN, INDIA, FROM THE ANALYSIS OF THE AFTERSHOCKS OF THE 2001 Mw 7.6 BHUJ EARTHQUAKE

    SciTech Connect (OSTI)

    Malagnini, L; Bodin, P; Mayeda, K; Akinci, A

    2005-05-04

    What can be learned about absolute site effects on ground motions and about earthquake source spectra from recordings at temporary seismic stations, none of which could be considered a 'reference' (hard rock) site, for which no geotechnical information is available, in a very poorly instrumented region? This challenge motivated our current study of aftershocks of the 2001 Mw 7.6 Bhuj earthquake, in Western India. Crustal attenuation and spreading relationships based on the same data used here were determined in an earlier study. In this paper we decouple the ambiguity between absolute source radiation and site effects by first computing robust estimates of moment-rate spectra of about 200 aftershocks in each of two depth ranges. Using these new estimates of sourcespectra, and our understanding of regional wave propagation, we extract the absolute site terms of the sites of the temporary deployment. Absolute site terms (one for each component of the ground motion, for each station) are computed in an average sense, via an L{sub 1}-norm minimization, and results for each site are averaged over wide ranges of azimuths and takeoff angles. The Bhuj deployment is characterized by a variable shallow geology, mostly of soft sedimentary units. Vertical site terms in the region were observed to be almost featureless and slightly < 1.0 within wide frequency ranges. As a result, H/V spectral ratios mimic the absolute behaviors of absolute horizontal site terms, and they generally overpredict them. On the contrary, with respect to the results for sedimentary rock sites (limestone, dolomite) obtained by Malagnini et al. (2004), H/V spectral ratios in their study did not have much in common with absolute horizontal site terms. Spectral ratios between the vector sum of the computed horizontal site terms for the temporary deployment with respect to the same quantity computed at the hardest rock station available, BAC1, are seriously biased by its non-flat, non-unitary site response

  20. Modeling an Application's Theoretical Minimum and Average Transactional Response Times

    SciTech Connect (OSTI)

    Paiz, Mary Rose

    2015-04-01

    The theoretical minimum transactional response time of an application serves as a ba- sis for the expected response time. The lower threshold for the minimum response time represents the minimum amount of time that the application should take to complete a transaction. Knowing the lower threshold is beneficial in detecting anomalies that are re- sults of unsuccessful transactions. On the converse, when an application's response time falls above an upper threshold, there is likely an anomaly in the application that is causing unusual performance issues in the transaction. This report explains how the non-stationary Generalized Extreme Value distribution is used to estimate the lower threshold of an ap- plication's daily minimum transactional response time. It also explains how the seasonal Autoregressive Integrated Moving Average time series model is used to estimate the upper threshold for an application's average transactional response time.

  1. Average M shell fluorescence yields for elements with 70≤Z≤92

    SciTech Connect (OSTI)

    Kahoul, A.; Deghfel, B.; Aylikci, V.; Aylikci, N. K.; Nekkab, M.

    2015-03-30

    The theoretical, experimental and analytical methods for the calculation of average M-shell fluorescence yield (ω{sup ¯}{sub M}) of different elements are very important because of the large number of their applications in various areas of physical chemistry and medical research. In this paper, the bulk of the average M-shell fluorescence yield measurements reported in the literature, covering the period 1955 to 2005 are interpolated by using an analytical function to deduce the empirical average M-shell fluorescence yield in the atomic range of 70≤Z≤92. The results were compared with the theoretical and fitted values reported by other authors. Reasonable agreement was typically obtained between our result and other works.

  2. Averaging cross section data so we can fit it

    SciTech Connect (OSTI)

    Brown, D.

    2014-10-23

    The 56Fe cross section we are interested in have a lot of fluctuations. We would like to fit the average of the cross section with cross sections calculated within EMPIRE. EMPIRE is a Hauser-Feshbach theory based nuclear reaction code, requires cross sections to be smoothed using a Lorentzian profile. The plan is to fit EMPIRE to these cross sections in the fast region (say above 500 keV).

  3. Electric Sales, Revenue, and Average Price 2011 - Energy Information

    U.S. Energy Information Administration (EIA) Indexed Site

    Administration Electricity Glossary › FAQS › Overview Data Electricity Data Browser (interactive query tool with charting & mapping) Summary Sales (consumption), revenue, prices & customers Generation and thermal output Capacity of electric power plants Consumption of fuels used to generate electricity Receipts of fossil-fuels for electricity generation Average cost of fossil-fuels for electricity generation Fossil-fuel stocks for electricity generation Cost, revenue and expense

  4. Average dynamics of a finite set of coupled phase oscillators

    SciTech Connect (OSTI)

    Dima, Germn C. Mindlin, Gabriel B.

    2014-06-15

    We study the solutions of a dynamical system describing the average activity of an infinitely large set of driven coupled excitable units. We compared their topological organization with that reconstructed from the numerical integration of finite sets. In this way, we present a strategy to establish the pertinence of approximating the dynamics of finite sets of coupled nonlinear units by the dynamics of its infinitely large surrogate.

  5. Influence of wind speed averaging on estimates of dimethylsulfide emission fluxes

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Chapman, E. G.; Shaw, W. J.; Easter, R. C.; Bian, X.; Ghan, S. J.

    2002-12-03

    The effect of various wind-speed-averaging periods on calculated DMS emission fluxes is quantitatively assessed. Here, a global climate model and an emission flux module were run in stand-alone mode for a full year. Twenty-minute instantaneous surface wind speeds and related variables generated by the climate model were archived, and corresponding 1-hour-, 6-hour-, daily-, and monthly-averaged quantities calculated. These various time-averaged, model-derived quantities were used as inputs in the emission flux module, and DMS emissions were calculated using two expressions for the mass transfer velocity commonly used in atmospheric models. Results indicate that the time period selected for averaging wind speedsmore » can affect the magnitude of calculated DMS emission fluxes. A number of individual marine cells within the global grid show DMS emissions fluxes that are 10-60% higher when emissions are calculated using 20-minute instantaneous model time step winds rather than monthly-averaged wind speeds, and at some locations the differences exceed 200%. Many of these cells are located in the southern hemisphere where anthropogenic sulfur emissions are low and changes in oceanic DMS emissions may significantly affect calculated aerosol concentrations and aerosol radiative forcing.« less

  6. COMPARISON OF VENTED AND ABSOLUTE PRESSURE TRANSDUCERS FOR WATER-LEVEL MONITORING IN HANFORD SITE CENTRAL PLATEAU WELLS

    SciTech Connect (OSTI)

    MCDONALD JP

    2011-09-08

    Automated water-level data collected using vented pressure transducers deployed in Hanford Site Central Plateau wells commonly display more variability than manual tape measurements in response to barometric pressure fluctuations. To explain this difference, it was hypothesized that vented pressure transducers installed in some wells are subject to barometric pressure effects that reduce water-level measurement accuracy. Vented pressure transducers use a vent tube, which is open to the atmosphere at land surface, to supply air pressure to the transducer housing for barometric compensation so the transducer measurements will represent only the water pressure. When using vented transducers, the assumption is made that the air pressure between land surface and the well bore is in equilibrium. By comparison, absolute pressure transducers directly measure the air pressure within the wellbore. Barometric compensation is achieved by subtracting the well bore air pressure measurement from the total pressure measured by a second transducer submerged in the water. Thus, no assumption of air pressure equilibrium is needed. In this study, water-level measurements were collected from the same Central Plateau wells using both vented and absolute pressure transducers to evaluate the different methods of barometric compensation. Manual tape measurements were also collected to evaluate the transducers. Measurements collected during this study demonstrated that the vented pressure transducers over-responded to barometric pressure fluctuations due to a pressure disequilibrium between the air within the wellbores and the atmosphere at land surface. The disequilibrium is thought to be caused by the relatively long time required for barometric pressure changes to equilibrate between land surface and the deep vadose zone and may be exacerbated by the restriction of air flow between the well bore and the atmosphere due to the presence of sample pump landing plates and well caps. The

  7. Table 4. Average value of photovoltaic modules, 2004-2014

    U.S. Energy Information Administration (EIA) Indexed Site

    Average value of photovoltaic modules, 2004-2014" "(dollars per peak watt)" "Year","Modules" 2004,2.99 2005,3.19 2006,3.5 2007,3.37 2008,3.49 2009,2.79 2010,1.96 2011,1.59 2012,1.15 2013,0.75 2014,0.87 "Source: U.S. Energy Information Administration, Form EIA-63B, 'Annual Photovoltaic Cell/Module Shipments Report.' Note: Dollars are not adjusted for inflation.

  8. Absolute total and partial dissociative cross sections of pyrimidine at electron and proton intermediate impact velocities

    SciTech Connect (OSTI)

    Wolff, Wania Luna, Hugo; Sigaud, Lucas; Montenegro, Eduardo C.; Tavares, Andre C.

    2014-02-14

    Absolute total non-dissociative and partial dissociative cross sections of pyrimidine were measured for electron impact energies ranging from 70 to 400 eV and for proton impact energies from 125 up to 2500 keV. MOs ionization induced by coulomb interaction were studied by measuring both ionization and partial dissociative cross sections through time of flight mass spectrometry and by obtaining the branching ratios for fragment formation via a model calculation based on the Born approximation. The partial yields and the absolute cross sections measured as a function of the energy combined with the model calculation proved to be a useful tool to determine the vacancy population of the valence MOs from which several sets of fragment ions are produced. It was also a key point to distinguish the dissociation regimes induced by both particles. A comparison with previous experimental results is also presented.

  9. Communication: Probing the absolute configuration of chiral molecules at aqueous interfaces

    SciTech Connect (OSTI)

    Lotze, Stephan Versluis, Jan; Olijve, Luuk L. C.; Schijndel, Luuk van; Milroy, Lech G.; Voets, Ilja K.; Bakker, Huib J.

    2015-11-28

    We demonstrate that the enantiomers of chiral macromolecules at an aqueous interface can be distinguished with monolayer sensitivity using heterodyne-detected vibrational sum-frequency generation (VSFG). We perform VSFG spectroscopy with a polarization combination that selectively probes chiral molecular structures. By using frequencies far detuned from electronic resonances, we probe the chiral macromolecular structures with high surface specificity. The phase of the sum-frequency light generated by the chiral molecules is determined using heterodyne detection. With this approach, we can distinguish right-handed and left-handed helical peptides at a water-air interface. We thus show that heterodyne-detected VSFG is sensitive to the absolute configuration of complex, interfacial macromolecules and has the potential to determine the absolute configuration of enantiomers at interfaces.

  10. Particle visualization in high-power impulse magnetron sputtering. II. Absolute density dynamics

    SciTech Connect (OSTI)

    Britun, Nikolay Palmucci, Maria; Konstantinidis, Stephanos; Snyders, Rony

    2015-04-28

    Time-resolved characterization of an Ar-Ti high-power impulse magnetron sputtering discharge has been performed. The present, second, paper of the study is related to the discharge characterization in terms of the absolute density of species using resonant absorption spectroscopy. The results on the time-resolved density evolution of the neutral and singly-ionized Ti ground state atoms as well as the metastable Ti and Ar atoms during the discharge on- and off-time are presented. Among the others, the questions related to the inversion of population of the Ti energy sublevels, as well as to re-normalization of the two-dimensional density maps in terms of the absolute density of species, are stressed.

  11. Absolute calibration of a charge-coupled device camera with twin beams

    SciTech Connect (OSTI)

    Meda, A.; Ruo-Berchera, I. Degiovanni, I. P.; Brida, G.; Rastello, M. L.; Genovese, M.

    2014-09-08

    We report on the absolute calibration of a Charge-Coupled Device (CCD) camera by exploiting quantum correlation. This method exploits a certain number of spatial pairwise quantum correlated modes produced by spontaneous parametric-down-conversion. We develop a measurement model accounting for all the uncertainty contributions, and we reach the relative uncertainty of 0.3% in low photon flux regime. This represents a significant step forward for the characterization of (scientific) CCDs used in mesoscopic light regime.

  12. Introducing an Absolute Cavity Pyrgeometer (ACP) for Improving the Atmospheric Longwave Irradiance Measurement (Poster)

    SciTech Connect (OSTI)

    Reda, I.; Stoffel, T.

    2012-03-01

    Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer (ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined by lowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the WISG.

  13. Predictive RANS simulations via Bayesian Model-Scenario Averaging

    SciTech Connect (OSTI)

    Edeling, W.N.; Cinnella, P.; Dwight, R.P.

    2014-10-15

    The turbulence closure model is the dominant source of error in most Reynolds-Averaged Navier–Stokes simulations, yet no reliable estimators for this error component currently exist. Here we develop a stochastic, a posteriori error estimate, calibrated to specific classes of flow. It is based on variability in model closure coefficients across multiple flow scenarios, for multiple closure models. The variability is estimated using Bayesian calibration against experimental data for each scenario, and Bayesian Model-Scenario Averaging (BMSA) is used to collate the resulting posteriors, to obtain a stochastic estimate of a Quantity of Interest (QoI) in an unmeasured (prediction) scenario. The scenario probabilities in BMSA are chosen using a sensor which automatically weights those scenarios in the calibration set which are similar to the prediction scenario. The methodology is applied to the class of turbulent boundary-layers subject to various pressure gradients. For all considered prediction scenarios the standard-deviation of the stochastic estimate is consistent with the measurement ground truth. Furthermore, the mean of the estimate is more consistently accurate than the individual model predictions.

  14. Table 19. Average Price of U.S. Coal Imports

    U.S. Energy Information Administration (EIA) Indexed Site

    9. Average Price of U.S. Coal Imports (dollars per short ton) Year to Date Continent and Country of Origin January - March 2016 October - December 2015 January - March 2015 2016 2015 Percent Change North America Total 71.92 104.33 107.02 71.92 107.02 -32.8 Canada 71.93 104.32 107.01 71.93 107.01 -32.8 Mexico 66.79 360.25 113.43 66.79 113.43 -41.1 South America Total 64.73 64.18 70.82 64.73 70.82 -8.6 Colombia 64.73 63.86 70.58 64.73 70.58 -8.3 Peru 63.31 86.76 86.19 63.31 86.19 -26.5 Venezuela -

  15. Table 22. Average Price of U.S. Coke Imports

    U.S. Energy Information Administration (EIA) Indexed Site

    2. Average Price of U.S. Coke Imports (dollars per short ton) Year to Date Continent and Country of Origin January - March 2016 October - December 2015 January - March 2015 2016 2015 Percent Change North America Total 181.85 113.11 213.82 181.85 213.82 -15.0 Canada 181.85 113.11 213.82 181.85 213.82 -15.0 Europe Total 270.94 416.80 770.50 270.94 770.50 -64.8 Austria - 1,788.00 - - - - France - 1,110.35 - - - - Germany, Federal Republic of - - 206.27 - 206.27 - Italy 265.37 300.11 - 265.37 - -

  16. Table 8. Average Price of U.S. Coal Exports

    U.S. Energy Information Administration (EIA) Indexed Site

    8. Average Price of U.S. Coal Exports (dollars per short ton) Year to Date Continent and Country of Destination January - March 2016 October - December 2015 January - March 2015 2016 2015 Percent Change North America Total 62.62 81.09 76.28 62.62 76.28 -17.9 Canada* 87.37 97.37 80.39 87.37 80.39 8.7 Dominican Republic 213.68 - 461.75 213.68 461.75 -53.7 Guatemala - 66.22 359.27 - 359.27 - Honduras 78.02 78.02 54.43 78.02 54.43 43.3 Jamaica 38.10 39.48 45.51 38.10 45.51 -16.3 Mexico 41.25 37.52

  17. U.S. Conventional, Average Refiner Gasoline Prices

    U.S. Energy Information Administration (EIA) Indexed Site

    346 1.209 1.450 1.617 1.790 1.894 1994-2016 Through Retail Outlets 1.345 1.209 1.451 1.617 1.791 1.895 1994-2016 Sales for Resale, Average 1.117 0.998 1.276 1.416 1.573 1.597 1994-2016 DTW 1.337 1.143 1.369 1.498 1.641 1.696 1994-2016 Rack 1.109 0.995 1.283 1.421 1.583 1.602 1994-2016 Bulk 1.137 0.991 1.194 1.339 1.451 1.522

  18. U.S. Reformulated, Average Refiner Gasoline Prices

    U.S. Energy Information Administration (EIA) Indexed Site

    790 1.553 1.736 1.921 2.011 2.078 1994-2016 Through Retail Outlets 1.792 1.554 1.737 1.921 2.012 2.079 1994-2016 Sales for Resale, Average 1.331 1.143 1.463 1.601 1.694 1.740 1994-2016 DTW 1.796 1.471 1.783 1.895 1.917 1.983 1994-2016 Rack 1.221 1.066 1.388 1.533 1.645 1.690 1994-2016 Bulk 1.307 1.074 1.377 1.514 1.602 1.619

  19. Average System Cost Methodology : Administrator's Record of Decision.

    SciTech Connect (OSTI)

    United States. Bonneville Power Administration.

    1984-06-01

    Significant features of average system cost (ASC) methodology adopted are: retention of the jurisdictional approach where retail rate orders of regulartory agencies provide primary data for computing the ASC for utilities participating in the residential exchange; inclusion of transmission costs; exclusion of construction work in progress; use of a utility's weighted cost of debt securities; exclusion of income taxes; simplification of separation procedures for subsidized generation and transmission accounts from other accounts; clarification of ASC methodology rules; more generous review timetable for individual filings; phase-in of reformed methodology; and each exchanging utility must file under the new methodology within 20 days of implementation by the Federal Energy Regulatory Commission of the ten major participating utilities, the revised ASC will substantially only affect three. (PSB)

  20. Gauge and averaging in gravitational self-force

    SciTech Connect (OSTI)

    Gralla, Samuel E.

    2011-10-15

    A difficulty with previous treatments of the gravitational self-force is that an explicit formula for the force is available only in a particular gauge (Lorenz gauge), where the force in other gauges must be found through a transformation law once the Lorenz-gauge force is known. For a class of gauges satisfying a 'parity condition' ensuring that the Hamiltonian center of mass of the particle is well-defined, I show that the gravitational self-force is always given by the angle average of the bare gravitational force. To derive this result I replace the computational strategy of previous work with a new approach, wherein the form of the force is first fixed up to a gauge-invariant piece by simple manipulations, and then that piece is determined by working in a gauge designed specifically to simplify the computation. This offers significant computational savings over the Lorenz gauge, since the Hadamard expansion is avoided entirely and the metric perturbation takes a very simple form. I also show that the rest mass of the particle does not evolve due to first-order self-force effects. Finally, I consider the 'mode sum regularization' scheme for computing the self-force in black hole background spacetimes, and use the angle-average form of the force to show that the same mode-by-mode subtraction may be performed in all parity-regular gauges. It appears plausible that suitably modified versions of the Regge-Wheeler and radiation gauges (convenient to Schwarzschild and Kerr, respectively) are in this class.

  1. Results of Second Outdoor Comparison Between Absolute Cavity Pyrgeometer (ACP) and Infrared Integrating Sphere (IRIS) Radiometer at PMOD (Presentation)

    SciTech Connect (OSTI)

    Reda, I.; Grobner, J.; Wacker, S.

    2014-01-01

    The Absolute Cavity Pyrgeometer (ACP) and InfraRed Integrating Sphere radiometer (IRIS) are developed to establish a world reference for calibrating pyrgeometers with traceability to SI units. The two radiometers are un-windowed with negligible spectral dependence, and traceable to SI units through the temperature scale (ITS-90). The second outdoor comparison between the two designs was held from September 30 to October 11, 2013 at the Physikalisch-Metorologisches Observatorium Davos (PMOD). The difference between the irradiance measured by ACP and that of the IRIS was within 1 W/m2 (3 IRISs: PMOD + Australia + Germany). From the first and second comparisons, a difference of 4-6 W/m2 was observed between the irradiance measured by ACP&IRIS and that of the interim World Infrared Standard Group (WISG). This presentation includes results from the first and second comparison in an effort to establish the world reference for pyrgeometer calibrations, a key deliverable for the World Meteorological Organization (WMO), and the DOE-ASR.

  2. Averaged Description of Flow (Steady and Transient) and Nonreactive Solute Transport in Random Porous Media

    SciTech Connect (OSTI)

    Schvidler, M.; Karasaki, K.

    2011-06-15

    In previous papers (Shvidler and Karasaki, 1999, 2001, 2005, and 2008) we presented and analyzed an approach for finding the general forms of exactly averaged equations of flow and transport in porous media. We studied systems of basic equations for steady flow with sources in unbounded domains with stochastically homogeneous conductivity fields. A brief analysis of exactly averaged equations of nonsteady flow and nonreactive solute transport was also presented. At the core of this approach is the existence of appropriate random Green's functions. For example, we showed that in the case of a 3-dimensional unbounded domain the existence of appropriate random Green's functions is sufficient for finding the exact nonlocal averaged equations for flow velocity using the operator with a unique kernel-vector. Examination of random fields with global symmetry (isotropy, transversal isotropy and orthotropy) makes it possible to describe significantly different types of averaged equations with nonlocal unique operators. It is evident that the existence of random Green's functions for physical linear processes is equivalent to assuming the existence of some linear random operators for appropriate stochastic equations. If we restricted ourselves to this assumption only, as we have done in this paper, we can study the processes in any dimensional bounded or unbounded fields and in addition, cases in which the random fields of conductivity and porosity are stochastically nonhomogeneous, nonglobally symmetrical, etc.. It is clear that examining more general cases involves significant difficulty and constricts the analysis of structural types for the processes being studied. Nevertheless, we show that we obtain the essential information regarding averaged equations for steady and transient flow, as well as for solute transport.

  3. Long-term average performance benefits of parabolic trough improvements

    SciTech Connect (OSTI)

    Gee, R.; Gaul, H.W.; Kearney, D.; Rabl, A.

    1980-03-01

    Improved parabolic trough concentrating collectors will result from better design, improved fabrication techniques, and the development and utilization of improved materials. The difficulty of achieving these improvements varies as does their potential for increasing parabolic trough performance. The purpose of this analysis is to quantify the relative merit of various technology advancements in improving the long-term average performance of parabolic trough concentrating collectors. The performance benefits of improvements are determined as a function of operating temperature for north-south, east-west, and polar mounted parabolic troughs. The results are presented graphically to allow a quick determination of the performance merits of particular improvements. Substantial annual energy gains are shown to be attainable. Of the improvements evaluated, the development of stable back-silvered glass reflective surfaces offers the largest performance gain for operating temperatures below 150/sup 0/C. Above 150/sup 0/C, the development of trough receivers that can maintain a vacuum is the most significant potential improvement. The reduction of concentrator slope errors also has a substantial performance benefit at high operating temperatures.

  4. Table 14a. Average Electricity Prices, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    a. Average Electricity Prices, Projected vs. Actual Projected Price in Constant Dollars (constant dollars, cents per kilowatt-hour in "dollar year" specific to each AEO) AEO $ Year 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 1992 6.80 6.80 6.90 6.90 6.90 6.90 7.00 7.00 7.10 7.10 7.20 7.20 7.20 7.30 7.30 7.40 7.50 7.60 AEO 1995 1993 6.80 6.80 6.70 6.70 6.70 6.70 6.70 6.80 6.80 6.90 6.90 6.90 7.00 7.00 7.10 7.10 7.20

  5. High average power magnetic modulator for copper lasers

    SciTech Connect (OSTI)

    Cook, E.G.; Ball, D.G.; Birx, D.L.; Branum, J.D.; Peluso, S.E.; Langford, M.D.; Speer, R.D.; Sullivan, J.R.; Woods, P.G.

    1991-06-14

    Magnetic compression circuits show the promise of long life for operation at high average powers and high repetition rates. When the Atomic Vapor Laser Isotope Separation (AVLIS) Program at Lawrence Livermore National Laboratory needed new modulators to drive their higher power copper lasers in the Laser Demonstration Facility (LDF), existing technology using thyratron switched capacitor inversion circuits did not meet the goal for long lifetimes at the required power levels. We have demonstrated that magnetic compression circuits can achieve this goal. Improving thyratron lifetime is achieved by increasing the thyratron conduction time, thereby reducing the effect of cathode depletion. This paper describes a three stage magnetic modulator designed to provide a 60 kV pulse to a copper laser at a 4. 5 kHz repetition rate. This modulator operates at 34 kW input power and has exhibited MTBF of {approx}1000 hours when using thyratrons and even longer MTBFs with a series of stack of SCRs for the main switch. Within this paper, the electrical and mechanical designs for the magnetic compression circuits are discussed as are the important performance parameters of lifetime and jitter. Ancillary circuits such as the charge circuit and reset circuit are shown. 8 refs., 5 figs., 1 tab.

  6. Ensemble bayesian model averaging using markov chain Monte Carlo sampling

    SciTech Connect (OSTI)

    Vrugt, Jasper A; Diks, Cees G H; Clark, Martyn P

    2008-01-01

    Bayesian model averaging (BMA) has recently been proposed as a statistical method to calibrate forecast ensembles from numerical weather models. Successful implementation of BMA however, requires accurate estimates of the weights and variances of the individual competing models in the ensemble. In their seminal paper (Raftery etal. Mon Weather Rev 133: 1155-1174, 2(05)) has recommended the Expectation-Maximization (EM) algorithm for BMA model training, even though global convergence of this algorithm cannot be guaranteed. In this paper, we compare the performance of the EM algorithm and the recently developed Differential Evolution Adaptive Metropolis (DREAM) Markov Chain Monte Carlo (MCMC) algorithm for estimating the BMA weights and variances. Simulation experiments using 48-hour ensemble data of surface temperature and multi-model stream-flow forecasts show that both methods produce similar results, and that their performance is unaffected by the length of the training data set. However, MCMC simulation with DREAM is capable of efficiently handling a wide variety of BMA predictive distributions, and provides useful information about the uncertainty associated with the estimated BMA weights and variances.

  7. Absolute wavelength calibration of a Doppler spectrometer with a custom Fabry-Perot optical system

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Absolute wavelength calibration of a Doppler spectrometer with a custom Fabry- Perot optical system M. M. Baltzer, D. Craig, D. J. Den Hartog, T. Nishizawa, and M. D. Nornberg Citation: Review of Scientific Instruments 87, 11E509 (2016); doi: 10.1063/1.4955491 View online: http://dx.doi.org/10.1063/1.4955491 View Table of Contents: http://scitation.aip.org/content/aip/journal/rsi/87/11?ver=pdfcov Published by the AIP Publishing Articles you may be interested in Development of a tunable

  8. Image plate characterization and absolute calibration to low kilo-electron-volt electrons

    SciTech Connect (OSTI)

    Busold, S.; Philipp, K.; Otten, A.; Roth, M.

    2014-11-15

    We report on the characterization of an image plate and its absolute calibration to electrons in the low keV energy range (130 keV). In our case, an Agfa MD4.0 without protection layer was used in combination with a Fuji FLA7000 scanner. The calibration data are compared to other published data and a consistent picture of the sensitivity of image plates to electrons is obtained, which suggests a validity of the obtained calibration up to 100 keV.

  9. The concepts of leak before break and absolute reliability of NPP equipment and piping

    SciTech Connect (OSTI)

    Getman, A.F.; Komarov, O.V.; Sokov, L.M.

    1997-04-01

    This paper describes the absolute reliability (AR) concept for ensuring safe operation of nuclear plant equipment and piping. The AR of a pipeline or component is defined as the level of reliability when the probability of an instantaneous double-ended break is near zero. AR analysis has been applied to Russian RBMK and VVER type reactors. It is proposed that analyses required for application of the leak before break concept should be included in AR implementation. The basic principles, methods, and approaches that provide the basis for implementing the AR concept are described.

  10. Absolute timing measurements of the Ni-like Pd and Sn soft-x-ray lasers

    SciTech Connect (OSTI)

    Staub, F.; Braud, M.; Balmer, J.E.; Nilsen, J.

    2005-10-15

    The absolute time of emission of the x-ray laser output with respect to the arrival of a 100-ps pump pulse has been measured with the aid of a calibrated timing fiducial. The results show the x-ray laser to appear up to 60 ps (80 ps) before the peak of the pump pulse in the case of the Sn (Pd) x-ray laser, which is in good agreement with simulations obtained from the LASNEX and CRETIN codes. The pulse duration was found to be {approx}45 ps for both the Sn and the Pd x-ray lasers.

  11. Fact #615: March 22, 2010 Average Vehicle Trip Length | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy 5: March 22, 2010 Average Vehicle Trip Length Fact #615: March 22, 2010 Average Vehicle Trip Length According to the latest National Household Travel Survey, the average trip length grew to over 10 miles in 2009, just slightly over the 9.9 mile average in 2001. Trips to work in 2009 increased to an average of 12.6 miles. The average trip length has been growing each survey year since the lowest average in 1983. Average Vehicle Trip Length, 1969-2009 Graph showing the average vehicle

  12. Using star tracks to determine the absolute pointing of the Fluorescence Detector telescopes of the Pierre Auger Observatory

    SciTech Connect (OSTI)

    De Donato, Cinzia; Sanchez, Federico; Santander, Marcos; Natl.Tech.U., San Rafael; Camin, Daniel; Garcia, Beatriz; Grassi, Valerio; /Milan U. /INFN, Milan

    2005-05-01

    To accurately reconstruct a shower axis from the Fluorescence Detector data it is essential to establish with high precision the absolute pointing of the telescopes. To d that they calculate the absolute pointing of a telescope using sky background data acquired during regular data taking periods. The method is based on the knowledge of bright star's coordinates that provide a reliable and stable coordinate system. it can be used to check the absolute telescope's pointing and its long-term stability during the whole life of the project, estimated in 20 years. They have analyzed background data taken from January to October 2004 to determine the absolute pointing of the 12 telescopes installed both in Los Leones and Coihueco. The method is based on the determination of the mean-time of the variance signal left by a star traversing a PMT's photocathode which is compared with the mean-time obtained by simulating the track of that star on the same pixel.

  13. Absolute measurement of the 242Pu neutron-capture cross section

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Buckner, M. Q.; Wu, C. Y.; Henderson, R. A.; Bucher, B.; Chyzh, A.; Bredeweg, T. A.; Baramsai, B.; Couture, A.; Jandel, M.; Mosby, S.; et al

    2016-04-21

    Here, the absolute neutron-capture cross section of 242Pu was measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. The first direct measurement of the 242Pu(n,γ) cross section was made over the incident neutron energy range from thermal to ≈ 6 keV, and the absolute scale of the (n,γ) cross section was set according to the known 239Pu(n,f) resonance at En,R = 7.83 eV. This was accomplished by adding a small quantity of 239Pu to the 242Pu sample. The relative scale of the crossmore » section, with a range of four orders of magnitude, was determined for incident neutron energies from thermal to ≈ 40 keV. Our data, in general, are in agreement with previous measurements and those reported in ENDF/B-VII.1; the 242Pu(n,γ) cross section at the En,R = 2.68 eV resonance is within 2.4% of the evaluated value. However, discrepancies exist at higher energies; our data are ≈30% lower than the evaluated data at En ≈ 1 keV and are approximately 2σ away from the previous measurement at En ≈ 20 keV.« less

  14. Constraining absolute neutrino masses via detection of galactic supernova neutrinos at JUNO

    SciTech Connect (OSTI)

    Lu, Jia-Shu; Cao, Jun; Li, Yu-Feng; Zhou, Shun

    2015-05-26

    A high-statistics measurement of the neutrinos from a galactic core-collapse supernova is extremely important for understanding the explosion mechanism, and studying the intrinsic properties of neutrinos themselves. In this paper, we explore the possibility to constrain the absolute scale of neutrino masses m{sub ν} via the detection of galactic supernova neutrinos at the Jiangmen Underground Neutrino Observatory (JUNO) with a 20 kiloton liquid-scintillator detector. In assumption of a nearly-degenerate neutrino mass spectrum and a normal mass ordering, the upper bound on the absolute neutrino mass is found to be m{sub ν}<(0.83±0.24) eV at the 95% confidence level for a typical galactic supernova at a distance of 10 kpc, where the mean value and standard deviation are shown to account for statistical fluctuations. For comparison, we find that the bound in the Super-Kamiokande experiment is m{sub ν}<(0.94±0.28) eV at the same confidence level. However, the upper bound will be relaxed when the model parameters characterizing the time structure of supernova neutrino fluxes are not exactly known, and when the neutrino mass ordering is inverted.

  15. ABSOLUTE FLUX CALIBRATION OF THE IRAC INSTRUMENT ON THE SPITZER SPACE TELESCOPE USING HUBBLE SPACE TELESCOPE FLUX STANDARDS

    SciTech Connect (OSTI)

    Bohlin, R. C.; Gordon, K. D.; Deustua, S.; Ferguson, H. C.; Flanagan, K.; Kalirai, J.; Meixner, M.; Rieke, G. H.; Engelbracht, C.; Su, K. Y. L.; Ardila, D.; Tremblay, P.-E.

    2011-05-15

    The absolute flux calibration of the James Webb Space Telescope (JWST) will be based on a set of stars observed by the Hubble and Spitzer Space Telescopes. In order to cross-calibrate the two facilities, several A, G, and white dwarf stars are observed with both Spitzer and Hubble and are the prototypes for a set of JWST calibration standards. The flux calibration constants for the four Spitzer IRAC bands 1-4 are derived from these stars and are 2.3%, 1.9%, 2.0%, and 0.5% lower than the official cold-mission IRAC calibration of Reach et al., i.e., in agreement within their estimated errors of {approx}2%. The causes of these differences lie primarily in the IRAC data reduction and secondarily in the spectral energy distributions of our standard stars. The independent IRAC 8 {mu}m band-4 fluxes of Rieke et al. are about 1.5% {+-} 2% higher than those of Reach et al. and are also in agreement with our 8 {mu}m result.

  16. Calculation of variable-base degree-days and degree-nights from monthly average temperatures

    SciTech Connect (OSTI)

    Sonderegger, R.; Cleary, P.; Dickinson, B.

    1985-01-01

    The Computerized Instrumented Residential Audit (CIRA), a micro-computer building energy analysis program developed at Lawrence Berkeley Laboratory, uses a monthly variable-base degree-day method to calculate heating and cooling loads. The method's unique feature is its ability to model thermostat setbacks and storage of solar gain. The program accomplishes this by dividing each day into two periods, ''average day'' (8 a.m. to 8 p.m.) and ''average night'' (8 p.m. to 8 a.m.), with different base temperatures. For each mode (heating or cooling) and for each period (day or night), the program reconstructs degree-days as a function of average monthly day or night temperature using three empirical coefficients specific to the location. A comparison is made between degree-days computed from hourly weather tapes and those predicted using this method. The root mean square error between predicted and actual degree days is typically between 3 and 12 degree-days per month. Tables of the coefficients are given for over 150 locations in the United States, computed from hourly dry-bulb temperatures on TRY and TMY tapes. Seasonal predictions of heating and cooling energy budgets using this method show good correspondence to the DOE-2 hourly simulation method.

  17. Fact #744: September 10, 2012 Average New Light Vehicle Price Grows Faster

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    than Average Used Light Vehicle Price | Department of Energy 4: September 10, 2012 Average New Light Vehicle Price Grows Faster than Average Used Light Vehicle Price Fact #744: September 10, 2012 Average New Light Vehicle Price Grows Faster than Average Used Light Vehicle Price In 2011 the average used light vehicle price was 36% higher than in 1990, while the average new light vehicle price was 67% higher than it was in 1990. The average price of a used vehicle had been between $6,000 and

  18. Measurement of the Absolute Branching Fraction of D0 to K- pi+

    SciTech Connect (OSTI)

    Aubert, B.; Bona, M.; Boutigny, D.; Karyotakis, Y.; Lees, J.P.; Poireau, V.; Prudent, X.; Tisserand, V.; Zghiche, A.; Garra Tico, J.; Grauges, E.; Lopez, L.; Palano, A.; Eigen, G.; Ofte, I.; Stugu, B.; Sun, L.; Abrams, G.S.; Battaglia, M.; Brown, D.N.; Button-Shafer, J.; /LBL, Berkeley /Birmingham U. /Ruhr U., Bochum /Bristol U. /British Columbia U. /Brunel U. /Novosibirsk, IYF /UC, Irvine /UCLA /UC, Riverside /UC, San Diego /UC, Santa Barbara /UC, Santa Cruz /Caltech /Cincinnati U. /Colorado U. /Colorado State U. /Dortmund U. /Munich, Tech. U. /Ecole Polytechnique /Edinburgh U. /Ferrara U. /Frascati /Genoa U. /Harvard U. /Heidelberg U. /Imperial Coll., London /Iowa U. /Iowa State U. /Johns Hopkins U. /Karlsruhe U. /Orsay, LAL /LLNL, Livermore /Liverpool U. /Queen Mary, U. of London /Royal Holloway, U. of London /Louisville U. /Manchester U. /Maryland U. /Massachusetts U., Amherst /MIT, LNS /McGill U. /Maryland U. /INFN, Milan /Mississippi U. /Montreal U. /Mt. Holyoke Coll. /Naples U. /NIKHEF, Amsterdam /Notre Dame U. /Ohio State U. /Oregon U. /Padua U. /Paris U., VI-VII /Pennsylvania U. /Perugia U. /Pisa U. /Prairie View A-M /Princeton U. /INFN, Rome /Rostock U. /Rutherford /DSM, DAPNIA, Saclay /South Carolina U. /SLAC /Stanford U., Phys. Dept. /SUNY, Albany /Tennessee U. /Texas U. /Texas U., Dallas /Turin U. /Trieste U. /Valencia U., IFIC /Victoria U. /Warwick U. /Wisconsin U., Madison /Yale U.

    2007-04-25

    The authors measure the absolute branching fraction for D{sup 0} {yields} K{sup -} {pi}{sup +} using partial reconstruction of {bar B}{sup 0} {yields} D*{sup +}X{ell}{sup -}{bar {nu}}{sub {ell}} decays, in which only the charged lepton and the pion from the decay D*{sup +} {yields} D{sup 0}{pi}{sup +} are used. Based on a data sample of 230 million B{bar B} pairs collected at the {Upsilon}(4S) resonance with the BABAR detector at the PEP-II asymmetric-energy B Factory at SLAC, they obtain {Beta}(D{sup 0} {yields} K{sup -}{pi}{sup +}) = (4.007 {+-} 0.037 {+-} 0.070)%, where the first error is statistical and the second error is systematic.

  19. Absolute differential cross sections for elastic scattering of electrons from pyrimidine

    SciTech Connect (OSTI)

    Maljkovic, J. B.; Milosavljevic, A. R.; Sevic, D.; Marinkovic, B. P.; Blanco, F.

    2009-05-15

    Differential cross sections (DCSs) for elastic scattering of electrons from pyrimidine (C{sub 4}H{sub 4}N{sub 2}) are presented for incident energies from 50 to 300 eV. The measurements were performed using a cross beam technique, for scattering angles from 20 deg. to 110 deg. The relative DCSs were measured as a function of both the angle and incident energy and the absolute DCSs were determined using the relative flow method. The calculations of electron interaction cross sections are based on a corrected form of the independent-atom method, known as the screen corrected additivity rule procedure and using an improved quasifree absorption model. Calculated results agree very well with the experiment.

  20. The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF

    SciTech Connect (OSTI)

    Casey, D. T.; Frenje, J. A.; Gatu Johnson, M.; Seguin, F. H.; Li, C. K.; Petrasso, R. D.; Glebov, V. Yu.; Katz, J.; Magoon, J.; Meyerhofer, D. D.; Sangster, T. C.; Shoup, M.; Ulreich, J.; Ashabranner, R. C.; Bionta, R. M.; Carpenter, A. C.; Felker, B.; Khater, H. Y.; LePape, S.; MacKinnon, A.; McKernan, M. A.; Moran, M.; Rygg, J. R.; Yeoman, M. F.; Zacharias, R.; Leeper, R. J.; Fletcher, K.; Farrell, M.; Jasion, D.; Kilkenny, J.; Paguio, R.

    2013-04-18

    The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, iontemperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

  1. The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Casey, D. T.; Frenje, J. A.; Gatu Johnson, M.; Seguin, F. H.; Li, C. K.; Petrasso, R. D.; Glebov, V. Yu.; Katz, J.; Magoon, J.; Meyerhofer, D. D.; et al

    2013-04-18

    The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, iontemperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describesmore » ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.« less

  2. Analog morphocorrelation: new technique with implications for high-resolution absolute age dating

    SciTech Connect (OSTI)

    Arnold, A.J.; Parker, W.C.; Berggren, W.A.

    1986-05-01

    The conventional approach to increased biostratigraphic resolution involves identifying additional datum planes defined by discrete events. Multivariate techniques used to refine a conventional taxonomic zonal scheme offer no improvement in precision; however, since the characters on which the zonal boundaries are based often show continuous stratigraphic variation, they offer an opportunity for continuous stratigraphic correlation based on the stage of evolution. Morphometric analysis was conducted on two lineages: (1) the Globorotalia cibaoensis-G. crassaformis linage, using a reference section from the early Pliocene of the Rio Grande rise, spanning approximately 2.6 m.y.; and (2) the G. conoidea-G.inflata lineage, using a reference section from the late Miocene to the Holocene from the southwest Pacific, spanning approximately 8 m.y. Stepwise multiple regression of morphologic variates generated an equation with an age-prediction precision (95% confidence) of +/- 122 k.y. in the G. crassaformis lineage and +/- 463 k.y. in the G conoidea lineage (accuracy depends on calibration of absolute dates in the reference section and our knowledge of sedimentation rates over the measured interval). Using single-equation analog morphocorrelation, any sample overlapped by the reference lineage can be correlated, which reduce the need for repeated sampling in a search for discrete events. The authors demonstrate that analysis of continuous morphologic variation can increase stratigraphic precision with a few carefully chosen variables, and that analog morpho-correlation can yield absolute dates, rather than relative dates with quantified error. Any disadvantages inherent in analog morphocorrelation are also found in conventional biostratigraphic techniques, but are usually unquantified and unrecognized.

  3. Fact #614: March 15, 2010 Average Age of Household Vehicles | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy 4: March 15, 2010 Average Age of Household Vehicles Fact #614: March 15, 2010 Average Age of Household Vehicles The average age of household vehicles has increased from 6.6 years in 1977 to 9.2 years in 2009. Pickup trucks have the oldest average age in every year listed. Sport utility vehicles (SUVs), first reported in the 1995 survey, have the youngest average age. Average Vehicle Age by Vehicle Type Graph showing the average vehicle age by type (car, van, pickup, SUV, all household

  4. Sci—Fri PM: Dosimetry — 03: Delta4 diode absolute dose response for large and small target volume IMRT QA

    SciTech Connect (OSTI)

    Simard, D; Thakur, V

    2014-08-15

    The goal of this project was to quantify the over-response/under-response of the Delta4 diodes for Helical Tomotherapy plans on extreme target volume sizes. A custom Delta4 phantom quarter with a hole to insert an ionisation chamber (IC) close to the center of the phantom have been used to acquire simultaneous IC and diodes absolute dose measurements. Eight plans for different target volumes were created from 20cm to 1cm diameter. Diodes dose measurements in the target were compared with IC measurement, to quantify absolute dose accuracy. IC measurements show a good agreement with planned dose (±2%). Diode measurements demonstrate a good agreement with IC for regular target size of 5 and 10cm (0 to 1%). For larger targets, an over-response is observed for FW 25mm and 10mm (2 to 3%). for small target of 1cm diameter, a major under-response is observed for FW 25mm and 10mm (−8 and −36%). The over-response could to be due to the extra amount of scattered radiation and the opposite for under-response. Although this scatter hypothesis still has to be proven, early testing demonstrates an over-response of 40%/20% of the central diodes compare to IC when an open helical rotational beam is delivered 75mm/25mm away from the center of the phantom. These results are in agreement with the real patient Delta4 DQA results at our center.

  5. ABSOLUTE TIMING OF THE CRAB PULSAR WITH THE INTEGRAL/SPI TELESCOPE

    SciTech Connect (OSTI)

    Molkov, S.; Jourdain, E.; Roques, J. P.

    2010-01-01

    We have investigated the pulse shape evolution of the Crab pulsar emission in the hard X-ray domain of the electromagnetic spectrum. In particular, we have studied the alignment of the Crab pulsar phase profiles measured in the hard X-rays and in other wavebands. To obtain the hard X-ray pulse profiles, we have used six years (2003-2009, with a total exposure of about 4 Ms) of publicly available data of the SPI telescope on-board the International Gamma-Ray Astrophysics Laboratory observatory, folded with the pulsar time solution derived from the Jodrell Bank Crab Pulsar Monthly Ephemeris. We found that the main pulse in the hard X-ray 20-100 keV energy band leads the radio one by 8.18 +- 0.46 milliperiods in phase, or 275 +- 15 mus in time. Quoted errors represent only statistical uncertainties. Our systematic error is estimated to be approx40 mus and is mainly caused by the radio measurement uncertainties. In hard X-rays, the average distance between the main pulse and interpulse on the phase plane is 0.3989 +- 0.0009. To compare our findings in hard X-rays with the soft 2-20 keV X-ray band, we have used data of quasi-simultaneous Crab observations with the proportional counter array monitor on-board the Rossi X-Ray Timing Explorer mission. The time lag and the pulses separation values measured in the 3-20 keV band are 0.00933 +- 0.00016 (corresponding to 310 +- 6 mus) and 0.40016 +- 0.00028 parts of the cycle, respectively. While the pulse separation values measured in soft X-rays and hard X-rays agree, the time lags are statistically different. Additional analysis show that the delay between the radio and X-ray signals varies with energy in the 2-300 keV energy range. We explain such a behavior as due to the superposition of two independent components responsible for the Crab pulsed emission in this energy band.

  6. Absolute calibration method for laser megajoule neutron yield measurement by activation diagnostics

    SciTech Connect (OSTI)

    Landoas, Olivier; Rosse, Bertrand; Briat, Michelle; Marmouget, Jean Gabriel; Varignon, Cyril; Ledoux, Xavier; Caillaud, Tony; Thfoin, Isabelle; Bourgade, Jean-Luc; Glebov, Vladimir Yu; Sangster, Thomas C.; Duffy, Tim; Disdier, Laurent

    2011-07-15

    The laser megajoule (LMJ) and the National Ignition Facility (NIF) plan to demonstrate thermonuclear ignition using inertial confinement fusion (ICF). The neutron yield is one of the most important parameters to characterize ICF experiment performance. For decades, the activation diagnostic was chosen as a reference at ICF facilities and is now planned to be the first nuclear diagnostic on LMJ, measuring both 2.45 MeV and 14.1 MeV neutron yields. Challenges for the activation diagnostic development are absolute calibration, accuracy, range requirement, and harsh environment. At this time, copper and zirconium material are identified for 14.1 MeV neutron yield measurement and indium material for 2.45 MeV neutrons. A series of calibrations were performed at Commissariat a l'Energie Atomique (CEA) on a Van de Graff facility to determine activation diagnostics efficiencies and to compare them with results from calculations. The CEA copper activation diagnostic was tested on the OMEGA facility during DT implosion. Experiments showed that CEA and Laboratory for Laser Energetics (LLE) diagnostics agree to better than 1% on the neutron yield measurement, with an independent calibration for each system. Also, experimental sensitivities are in good agreement with simulations and allow us to scale activation diagnostics for the LMJ measurement range.

  7. ARCADE 2 MEASUREMENT OF THE ABSOLUTE SKY BRIGHTNESS AT 3-90 GHz

    SciTech Connect (OSTI)

    Fixsen, D. J.; Levin, S.; Seiffert, M.; Limon, M.; Lubin, P.; Mirel, P.; Singal, J.; Villela, T.; Wuensche, C. A.

    2011-06-10

    The ARCADE 2 instrument has measured the absolute temperature of the sky at frequencies 3, 8, 10, 30, and 90 GHz, using an open-aperture cryogenic instrument observing at balloon altitudes with no emissive windows between the beam-forming optics and the sky. An external blackbody calibrator provides an in situ reference. Systematic errors were greatly reduced by using differential radiometers and cooling all critical components to physical temperatures approximating the cosmic microwave background (CMB) temperature. A linear model is used to compare the output of each radiometer to a set of thermometers on the instrument. Small corrections are made for the residual emission from the flight train, balloon, atmosphere, and foreground Galactic emission. The ARCADE 2 data alone show an excess radio rise of 54 {+-} 6 mK at 3.3 GHz in addition to a CMB temperature of 2.731 {+-} 0.004 K. Combining the ARCADE 2 data with data from the literature shows an excess power-law spectrum of T = 24.1 {+-} 2.1 (K) ({nu}/{nu}{sub 0}){sup -2.599{+-}0.036} from 22 MHz to 10 GHz ({nu}{sub 0} = 310 MHz) in addition to a CMB temperature of 2.725 {+-} 0.001 K.

  8. Fact #715: February 20, 2012 The Average Age of Light Vehicles Continues to Rise

    Broader source: Energy.gov [DOE]

    The average age for cars and light trucks continues to rise as consumers hold onto their vehicles longer. Between 1995 and 2011, the average age for cars increased by 32% from 8.4 years to 11.1...

  9. Setting Whole-Building Absolute Energy Use Targets for the K-12 School, Retail, and Healthcare Sectors: Preprint

    SciTech Connect (OSTI)

    Leach, M.; Bonnema, E.; Pless, S.; Torcellini, P.

    2012-08-01

    This paper helps owners' efficiency representatives to inform executive management, contract development, and project management staff as to how specifying and applying whole-building absolute energy use targets for new construction or renovation projects can improve the operational energy performance of commercial buildings.

  10. Hubble space telescope absolute proper motions of NGC 6681 (M70) and the sagittarius dwarf spheroidal galaxy

    SciTech Connect (OSTI)

    Massari, D.; Ferraro, F. R.; Dalessandro, E.; Lanzoni, B.

    2013-12-10

    We have measured absolute proper motions for the three populations intercepted in the direction of the Galactic globular cluster NGC 6681: the cluster itself, the Sagittarius dwarf spheroidal galaxy, and the field. For this, we used Hubble Space Telescope ACS/WFC and WFC3/UVIS optical imaging data separated by a temporal baseline of 5.464 yr. Five background galaxies were used to determine the zero point of the absolute-motion reference frame. The resulting absolute proper motion of NGC 6681 is (?{sub ?}cos ?, ?{sub ?}) = (1.58 0.18, 4.57 0.16) mas yr{sup 1}. This is the first estimate ever made for this cluster. For the Sgr dSph we obtain (?{sub ?}cos ?, ?{sub ?}) = 2.54 0.18, 1.19 0.16) mas yr{sup 1}, consistent with previous measurements and with the values predicted by theoretical models. The absolute proper motion of the Galaxy population in our field of view is (?{sub ?}cos ?, ?{sub ?}) = ( 1.21 0.27, 4.39 0.26) mas yr{sup 1}. In this study we also use background Sagittarius Dwarf Spheroidal stars to determine the rotation of the globular cluster in the plane of the sky and find that NGC 6681 is not rotating significantly: v {sub rot} = 0.82 1.02 km s{sup 1} at a distance of 1' from the cluster center.

  11. A zonally averaged, three-basin ocean circulation model for climate studies

    SciTech Connect (OSTI)

    Hovine, S.; Fichefet, T.

    1994-09-01

    A two-dimensional, three-basin ocean model suitable for long-term climate studies is developed. The model is based on the zonally averaged form of the primitive equations written in spherical coordinates. The east-west density difference which arises upon averaging the momentum equations is taken to be proportional to the meridional density gradient. Lateral exchanges of heat and salt between the basins are explicitly resolved. Moreover, the model includes bottom topography and has representations of the Arctic Ocean and of the Weddell and Ross seas. Under realistic restoring boundary conditions, the model reproduces the global conveyor belt: deep water is formed in the Atlantic between 60 and 70{degree}N at a rate of about 17 Sv (1 Sv=10{sup 6} m{sup 3}S{sup {minus}1}) and in the vicinity of the Antarctic continent, while the Indian and Pacific basins show broad upwelling. Superimposed on this thermohaline circulation are vigorous wind-driven cells in the upper thermocline. The simulated temperature and salinity fields and the computed meridional heat transport compare reasonably well with the observational estimates. When mixed boundary conditions i.e., a restoring condition no sea-surface temperature and flux condition on sea-surface salinity are applied, the model exhibits an irregular behavior before reaching a steady state characterized by self-sustained oscillations of 8.5-y period. The conveyor-belt circulation always results at this stage. A series of perturbation experiments illustrates the ability of the model to reproduce different steady-state circulations under mixed boundary conditions. Finally, the model sensitivity to various factors is examined. This sensitivity study reveals that the bottom topography and the presence of a submarine meridional ridge in the zone of the Drake passage play a crucial role in determining the properties of the model bottom-water masses. The importance of the seasonality of the surface forcing is also stressed.

  12. Evaluation of machine learning algorithms for prediction of regions of high Reynolds averaged Navier Stokes uncertainty

    SciTech Connect (OSTI)

    Ling, Julia; Templeton, Jeremy Alan

    2015-08-04

    Reynolds Averaged Navier Stokes (RANS) models are widely used in industry to predict fluid flows, despite their acknowledged deficiencies. Not only do RANS models often produce inaccurate flow predictions, but there are very limited diagnostics available to assess RANS accuracy for a given flow configuration. If experimental or higher fidelity simulation results are not available for RANS validation, there is no reliable method to evaluate RANS accuracy. This paper explores the potential of utilizing machine learning algorithms to identify regions of high RANS uncertainty. Three different machine learning algorithms were evaluated: support vector machines, Adaboost decision trees, and random forests. The algorithms were trained on a database of canonical flow configurations for which validated direct numerical simulation or large eddy simulation results were available, and were used to classify RANS results on a point-by-point basis as having either high or low uncertainty, based on the breakdown of specific RANS modeling assumptions. Classifiers were developed for three different basic RANS eddy viscosity model assumptions: the isotropy of the eddy viscosity, the linearity of the Boussinesq hypothesis, and the non-negativity of the eddy viscosity. It is shown that these classifiers are able to generalize to flows substantially different from those on which they were trained. As a result, feature selection techniques, model evaluation, and extrapolation detection are discussed in the context of turbulence modeling applications.

  13. Evaluation of machine learning algorithms for prediction of regions of high Reynolds averaged Navier Stokes uncertainty

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Ling, Julia; Templeton, Jeremy Alan

    2015-08-04

    Reynolds Averaged Navier Stokes (RANS) models are widely used in industry to predict fluid flows, despite their acknowledged deficiencies. Not only do RANS models often produce inaccurate flow predictions, but there are very limited diagnostics available to assess RANS accuracy for a given flow configuration. If experimental or higher fidelity simulation results are not available for RANS validation, there is no reliable method to evaluate RANS accuracy. This paper explores the potential of utilizing machine learning algorithms to identify regions of high RANS uncertainty. Three different machine learning algorithms were evaluated: support vector machines, Adaboost decision trees, and random forests.more » The algorithms were trained on a database of canonical flow configurations for which validated direct numerical simulation or large eddy simulation results were available, and were used to classify RANS results on a point-by-point basis as having either high or low uncertainty, based on the breakdown of specific RANS modeling assumptions. Classifiers were developed for three different basic RANS eddy viscosity model assumptions: the isotropy of the eddy viscosity, the linearity of the Boussinesq hypothesis, and the non-negativity of the eddy viscosity. It is shown that these classifiers are able to generalize to flows substantially different from those on which they were trained. As a result, feature selection techniques, model evaluation, and extrapolation detection are discussed in the context of turbulence modeling applications.« less

  14. ELLIPSOIDAL VARIABLE V1197 ORIONIS: ABSOLUTE LIGHT-VELOCITY ANALYSIS FOR KNOWN DISTANCE

    SciTech Connect (OSTI)

    Wilson, R. E.; Chochol, D.; KomzIk, R.; Van Hamme, W.; Pribulla, T.; Volkov, I.

    2009-09-01

    V1197 Orionis light curves from a long-term observing program for red giant binaries show ellipsoidal variation of small amplitude in the V and R{sub C} bands, although not clearly in U and B. Eclipses are not detected. All four bands show large irregular intrinsic variations, including fleeting quasi-periodicities identified by power spectra, that degrade analysis and may be caused by dynamical tides generated by orbital eccentricity. To deal with the absence of eclipses and consequent lack of astrophysical and geometrical information, direct use is made of the Hipparcos parallax distance while the V and R{sub C} light curves and (older) radial velocity curves are analyzed simultaneously in terms of absolute flux. The red giant's temperature is estimated from new spectra. This type of analysis, called Inverse Distance Estimation for brevity, is new and can also be applied to other ellipsoidal variables. Advantages gained by utilization of definite distance and temperature are discussed in regard to how radius, fractional lobe filling, and mass ratio information are expressed in the observations. The advantages were tested in solutions of noisy synthetic data. Also discussed and tested by simulations are ideas on the optimal number of light curves to be solved simultaneously under various conditions. The dim companion has not been observed or discussed in the literature but most solutions find its mass to be well below that of the red giant. Solutions show red giant masses that are too low for evolution to the red giant stage within the age of the Galaxy, although that result is probably an artifact of the intrinsic brightness fluctuations.

  15. Fact #910: February 1, 2016 Study Shows Average Cost of Electric Vehicle

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Charger Installations - Dataset | Department of Energy 0: February 1, 2016 Study Shows Average Cost of Electric Vehicle Charger Installations - Dataset Fact #910: February 1, 2016 Study Shows Average Cost of Electric Vehicle Charger Installations - Dataset Excel file and dataset for Study Shows Average Cost of Electric Vehicle Charger Installations fotw#910_web.xlsx (16.26 KB) More Documents & Publications Fact #909: January 25, 2016 Workplace Charging Accounts for About a Third of All

  16. A comparison of absolute calibrations of a radiation thermometer based on a monochromator and a tunable source

    SciTech Connect (OSTI)

    Keawprasert, T.; Anhalt, K.; Taubert, D. R.; Sperling, A.; Schuster, M.; Nevas, S.

    2013-09-11

    An LP3 radiation thermometer was absolutely calibrated at a newly developed monochromator-based set-up and the TUneable Lasers in Photometry (TULIP) facility of PTB in the wavelength range from 400 nm to 1100 nm. At both facilities, the spectral radiation of the respective sources irradiates an integrating sphere, thus generating uniform radiance across its precision aperture. The spectral irradiance of the integrating sphere is determined via an effective area of a precision aperture and a Si trap detector, traceable to the primary cryogenic radiometer of PTB. Due to the limited output power from the monochromator, the absolute calibration was performed with the measurement uncertainty of 0.17 % (k= 1), while the respective uncertainty at the TULIP facility is 0.14 %. Calibration results obtained by the two facilities were compared in terms of spectral radiance responsivity, effective wavelength and integral responsivity. It was found that the measurement results in integral responsivity at the both facilities are in agreement within the expanded uncertainty (k= 2). To verify the calibration accuracy, the absolutely calibrated radiation thermometer was used to measure the thermodynamic freezing temperatures of the PTB gold fixed-point blackbody.

  17. Plan averaging for multicriteria navigation of sliding window IMRT and VMAT

    SciTech Connect (OSTI)

    Craft, David Papp, Dávid; Unkelbach, Jan

    2014-02-15

    Purpose: To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. Methods: The authors show that by taking an appropriately defined average of leaf trajectories of sliding window plans, the authors obtain a sliding window plan whose fluence map is the exact average of the fluence maps corresponding to the initial plans. In the case of static-beam IMRT, this also implies that the dose distribution of the averaged plan is the exact dosimetric average of the initial plans. In VMAT delivery, the dose distribution of the averaged plan is a close approximation of the dosimetric average of the initial plans. Results: The authors demonstrate the method on three Pareto optimal VMAT plans created for a demanding paraspinal case, where the tumor surrounds the spinal cord. The results show that the leaf averaged plans yield dose distributions that approximate the dosimetric averages of the precomputed Pareto optimal plans well. Conclusions: The proposed method enables the navigation of deliverable Pareto optimal plans directly, i.e., interactive multicriteria exploration of deliverable sliding window IMRT and VMAT plans, eliminating the need for a sequencing step after navigation and hence the dose degradation that is caused by such a sequencing step.

  18. Fact #889: September 7, 2015 Average Diesel Price Lower than Gasoline for

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    the First Time in Six Years | Department of Energy 9: September 7, 2015 Average Diesel Price Lower than Gasoline for the First Time in Six Years Fact #889: September 7, 2015 Average Diesel Price Lower than Gasoline for the First Time in Six Years SUBSCRIBE to the Fact of the Week In July of 2015, the nationwide average price of diesel was lower than the average price of a regular gallon of gasoline for the first time since June 2009. Both gasoline and diesel prices fluctuate throughout the

  19. Fact #915: March 7, 2016 Average Historical Annual Gasoline Pump Price,

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    1929-2015 - Dataset | Department of Energy 5: March 7, 2016 Average Historical Annual Gasoline Pump Price, 1929-2015 - Dataset Fact #915: March 7, 2016 Average Historical Annual Gasoline Pump Price, 1929-2015 - Dataset Excel file and dataset for Average Historical Annual Gasoline Pump Price, 1929-2015 fotw#915_web.xlsx (24.76 KB) More Documents & Publications Fact #835: August 25, 2014 Average Annual Gasoline Pump Price, 1929-2013 - Dataset Fact #888: August 31, 2015 Historical Gas

  20. Fact #835: August 25, 2014 Average Annual Gasoline Pump Price, 1929-2013

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    - Dataset | Department of Energy 5: August 25, 2014 Average Annual Gasoline Pump Price, 1929-2013 - Dataset Fact #835: August 25, 2014 Average Annual Gasoline Pump Price, 1929-2013 - Dataset Excel file with dataset for Fact #835: Average Annual Gasoline Pump Price, 1929-2013 fotw#835_web.xlsx (21.31 KB) More Documents & Publications Fact #915: March 7, 2016 Average Historical Annual Gasoline Pump Price, 1929-2015 - Dataset Fact #888: August 31, 2015 Historical Gas Prices - Dataset

  1. Gasoline price to average below $2 in 2016 for first time in 12 years

    U.S. Energy Information Administration (EIA) Indexed Site

    Gasoline price to average below $2 in 2016 for first time in 12 years The annual average price for U.S. regular-grade gasoline is expected to fall below $2 per gallon this year for the first time since 2004. In its new monthly forecast, the U.S. Energy Information Administration said drivers will pay on average $1.98 per gallon to fill up at the pump with regular-grade gasoline. EIA expects the monthly average price of gasoline to reach a seven-year low of $1.82 per gallon in February, before

  2. Table 7.4 Average Prices of Selected Purchased Energy Sources...

    U.S. Energy Information Administration (EIA) Indexed Site

    4 Average Prices of Selected Purchased Energy Sources, 2002;" " Level: National and Regional Data; " " Row: Values of Shipments and Employment Sizes;" " Column: Energy Sources;" " ...

  3. A comparison of spatial averaging and Cadzow's method for array wavenumber estimation

    SciTech Connect (OSTI)

    Harris, D.B.; Clark, G.A.

    1989-10-31

    We are concerned with resolving superimposed, correlated seismic waves with small-aperture arrays. The limited time-bandwidth product of transient seismic signals complicates the task. We examine the use of MUSIC and Cadzow's ML estimator with and without subarray averaging for resolution potential. A case study with real data favors the MUSIC algorithm and a multiple event covariance averaging scheme.

  4. Cylinder-averaged histories of nitrogen oxide in a D.I. diesel with simulated turbocharging

    SciTech Connect (OSTI)

    Donahue, R.J.; Borman, G.L.; Bower, G.R.

    1994-10-20

    An experimental study was conducted using the dumping technique (total cylinder sampling) to produce cylinder mass-averaged nitric oxide histories. Data were taken using a four stroke diesel research engine employing a quiescent chamber, high pressure direct ijection fuel system, and simulated turbocharging. Two fuels were used to determine fuel cetane number effects. Two loads were run, one at an equivalence ratio of 0.5 and the other at a ratio of 0.3. The engine speed was held constant at 1500 rpm. Under the turbocharged and retarded timing conditions of this study, nitric oxide was produced up to the point of about 85% mass burned. Two different models were used to simulate the engine mn conditions: the phenomenological Hiroyasu spray-combustion model, and the three dimensional, U.W.-ERO modified KIVA-lI computational fluid dynamic code. Both of the models predicted the correct nitric oxide trend. Although the modified KIVA-lI combustion model using Zeldovich kinetics correctly predicted the shapes of the nitric oxide histories, it did not predict the exhaust concentrations without arbitrary adjustment based on experimental values.

  5. Dynamical interpretation of average fission-fragment kinetic energy systematics and nuclear scission

    SciTech Connect (OSTI)

    Nadtochy, P.N. [GSI, Plankstrasse 1, D-64291 Darmstadt (Germany); Omsk State University, Department of Theoretical Physics, Mira Prospect 55-A, RU-644077 Omsk (Russian Federation); Adeev, G.D. [Omsk State University, Department of Theoretical Physics, Mira Prospect 55-A, RU-644077 Omsk (Russian Federation)

    2005-11-01

    A dynamical interpretation of the well-known systematics for average total kinetic energy of fission fragments over a wide range of the Coulomb parameter (600Different scission criteria traditionally employed in fission theory--at zero neck radius and at finite neck radius--have been applied in dynamical calculations. Both have resulted in a fairly good description of the dependence of on the Coulomb parameter. The results of dynamical calculations of within three-dimensional Langevin dynamics show that the mean distance between the centers of mass of nascent fragments at the scission configuration increases linearly with the parameter Z{sup 2}/A{sup 1/3}. This distance changes approximately from 2.35R{sub 0} for {sup 119}Xe to 2.6R{sub 0} for {sup 256}Fm. In spite of this increase in mean distance between future fragments at scission, the linear dependence of on the parameter Z{sup 2}/A{sup 1/3} remains approximately valid over a wide range of the Coulomb parameter Z{sup 2}/A{sup 1/3}.

  6. Areal-averaged and Spectrally-resolved Surface Albedo from Ground-based Transmission Data Alone: Toward an Operational Retrieval

    SciTech Connect (OSTI)

    Kassianov, Evgueni I.; Barnard, James C.; Flynn, Connor J.; Riihimaki, Laura D.; Michalsky, Joseph; Hodges, G. B.

    2014-08-22

    We present here a simple retrieval of the areal-averaged and spectrally resolved surface albedo using only ground-based measurements of atmospheric transmission under fully overcast conditions. Our retrieval is based on a one-line equation and widely accepted assumptions regarding the weak spectral dependence of cloud optical properties in the visible and near-infrared spectral range. The feasibility of our approach for the routine determinations of albedo is demonstrated for different landscapes with various degrees of heterogeneity using three sets of measurements:(1) spectrally resolved atmospheric transmission from Multi-Filter Rotating Shadowband Radiometer (MFRSR) at wavelength 415, 500, 615, 673, and 870 nm, (2) tower-based measurements of local surface albedo at the same wavelengths, and (3) areal-averaged surface albedo at four wavelengths (470, 560, 670 and 860 nm) from collocated and coincident Moderate Resolution Imaging Spectroradiometer (MODIS) observations. These integrated datasets cover both long (2008-2013) and short (April-May, 2010) periods at the ARM Southern Great Plains (SGP) site and the NOAA Table Mountain site, respectively. The calculated root mean square error (RMSE), which is defined here as the root mean squared difference between the MODIS-derived surface albedo and the retrieved area-averaged albedo, is quite small (RMSE≤0.01) and comparable with that obtained previously by other investigators for the shortwave broadband albedo. Good agreement between the tower-based daily averages of surface albedo for the completely overcast and non-overcast conditions is also demonstrated. This agreement suggests that our retrieval originally developed for the overcast conditions likely will work for non-overcast conditions as well.

  7. SU-C-207-02: A Method to Estimate the Average Planar Dose From a C-Arm CBCT Acquisition

    SciTech Connect (OSTI)

    Supanich, MP

    2015-06-15

    Purpose: The planar average dose in a C-arm Cone Beam CT (CBCT) acquisition had been estimated in the past by averaging the four peripheral dose measurements in a CTDI phantom and then using the standard 2/3rds peripheral and 1/3 central CTDIw method (hereafter referred to as Dw). The accuracy of this assumption has not been investigated and the purpose of this work is to test the presumed relationship. Methods: Dose measurements were made in the central plane of two consecutively placed 16cm CTDI phantoms using a 0.6cc ionization chamber at each of the 4 peripheral dose bores and in the central dose bore for a C-arm CBCT protocol. The same setup was scanned with a circular cut-out of radiosensitive gafchromic film positioned between the two phantoms to capture the planar dose distribution. Calibration curves for color pixel value after scanning were generated from film strips irradiated at different known dose levels. The planar average dose for red and green pixel values was calculated by summing the dose values in the irradiated circular film cut out. Dw was calculated using the ionization chamber measurements and film dose values at the location of each of the dose bores. Results: The planar average dose using both the red and green pixel color calibration curves were within 10% agreement of the planar average dose estimated using the Dw method of film dose values at the bore locations. Additionally, an average of the planar average doses calculated using the red and green calibration curves differed from the ionization chamber Dw estimate by only 5%. Conclusion: The method of calculating the planar average dose at the central plane of a C-arm CBCT non-360 rotation by calculating Dw from peripheral and central dose bore measurements is a reasonable approach to estimating the planar average dose. Research Grant, Siemens AG.

  8. Fact #889: September 7, 2015 Average Diesel Price Lower than Gasoline for

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    the First Time in Six Years - Dataset | Department of Energy 9: September 7, 2015 Average Diesel Price Lower than Gasoline for the First Time in Six Years - Dataset Fact #889: September 7, 2015 Average Diesel Price Lower than Gasoline for the First Time in Six Years - Dataset Excel file and dataset for Average Diesel Price Lower than Gasoline for the First Time in Six Years fotw#889_web.xlsx (19.04 KB) More Documents & Publications Fact #859 February 9, 2015 Excess Supply is the Most

  9. Average U.S. household to spend $710 less on gasoline during 2015

    U.S. Energy Information Administration (EIA) Indexed Site

    drivers to see big savings at the gasoline pump this summer U.S. consumers are expected to pay the lowest average price for gasoline in six years during this summer's driving season, mostly because of lower crude oil costs. In its new forecast, the U.S. Energy Information Administration said the price for regular gasoline should average $2.45 per gallon this summer. That's down more than a dollar from the $3.59 per gallon seen last summer, and the cheapest average summer pump price since 2009.

  10. Average household expected to save $675 at the pump in 2015

    U.S. Energy Information Administration (EIA) Indexed Site

    Average household expected to save $675 at the pump in 2015 Although retail gasoline prices have risen in recent weeks U.S. consumers are still expected to save about $675 per household in motor fuel costs this year. In its new monthly forecast, the U.S. Energy Information Administration says the average pump price for regular grade gasoline in 2015 will be $2.43 per gallon. That's about 93 cents lower than last year's average. The savings for consumers will be even bigger during the

  11. Diesel prices continue to increase … U.S. average over $4

    U.S. Energy Information Administration (EIA) Indexed Site

    Diesel prices continue to increase - U.S. average over $4 The U.S. average retail price for on-highway diesel fuel broke the 4-dollar mark for the first time since last March. The U.S. retail average rose to $4.02 a gallon. That's up 2.8 cents from a week ago, based on the weekly price survey by the U.S. Energy Information Administration. Diesel prices were highest in the New England region at 4.39 a gallon, up 1.3 cents from a week ago. Prices were lowest in the Gulf Coast states at 3.81 a

  12. Fact #622: May 10, 2010 Average Length of Light Vehicle Ownership |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy 2: May 10, 2010 Average Length of Light Vehicle Ownership Fact #622: May 10, 2010 Average Length of Light Vehicle Ownership Vehicle owners are holding onto their vehicles for a longer period, according to data from R.L. Polk and Company. The vehicle retention trends show that owners held onto a new vehicle for 56.3 months in 2008, up from 48.4 months six years earlier. New vehicle owners hold onto vehicles about 15 or 16 months longer than used vehicle owners. Average

  13. Fact #624: May 24, 2010 Corporate Average Fuel Economy Standards, Model

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Years 2012-2016 | Department of Energy 4: May 24, 2010 Corporate Average Fuel Economy Standards, Model Years 2012-2016 Fact #624: May 24, 2010 Corporate Average Fuel Economy Standards, Model Years 2012-2016 The final rule for the Corporate Average Fuel Economy (CAFE) Standards was published in March 2010. Under this rule, each light vehicle model produced for sale in the United States will have a fuel economy target based on its footprint. A vehicle's footprint is defined as the wheelbase

  14. Fact #638: August 30, 2010 Average Expenditure for a New Car Declines in

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Relation to Family Earnings | Department of Energy 8: August 30, 2010 Average Expenditure for a New Car Declines in Relation to Family Earnings Fact #638: August 30, 2010 Average Expenditure for a New Car Declines in Relation to Family Earnings Although the average expenditure for a new car has increased from 1967 to 2009, family earnings have also been on the rise. For this period, new car expenditures went from $3,216 to $23,186, while median family earnings went from $7,933 to $77,149.

  15. Fact #915: March 7, 2016 Average Historical Annual Gasoline Pump Price,

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    1929-2015 | Department of Energy 915: March 7, 2016 Average Historical Annual Gasoline Pump Price, 1929-2015 Fact #915: March 7, 2016 Average Historical Annual Gasoline Pump Price, 1929-2015 SUBSCRIBE to the Fact of the Week When adjusted for inflation, the average annual price of gasoline has fluctuated greatly, and has recently experienced sharp increases and decreases. The effect of the U.S. embargo of oil from Iran can be seen in the early 1980's with the price of gasoline peaking in

  16. Determination of the absolute configuration of (-)-(2R)-succinic-2-d acid by neutron diffraction study: Unambiguous proof of the absolute stereochemistry of the NAD/sup +//NADH interconversion

    SciTech Connect (OSTI)

    Yuan, H.S.H.; Stevens, R.C.; Fujita, S.; Watkins, M.I.; Koetzle, T.F.; Bau, R.

    1988-05-01

    The absolute configuration of the CHD group (D = deuterium) in (-)-(2R)-succinic-2-d acid, as prepared from (-)-(2S,3R)-malic-3-d acid, has been shown unambiguously to be R by the technique of single-crystal neutron diffraction. The optically active cation (+)-phenylethylammonium was used as the chiral reference. The structure of (C/sub 6/H/sub 5/CH/sub 3/CHNH/sub 3/)/sup +/(HOOCCH/sub 2/CHDCOOO)/sup -/ has been studied with x-ray diffraction at room temperature and neutron diffraction at room temperature and neutron diffraction at 100 K. Crystal data from the neutron diffraction analysis of the phenylethylammonium slat of the title compound at 100 K: space group P2/sub 1/; a = 8.407 /angstrom/, b = 8.300 /angstrom/, c = 8.614 /angstrom/, ..beta.. = 91.20/degrees/; unit cell volume = 600.9 /angstrom//sup 3/, Z = 2. The result confirms the stereochemistry of the malate/succinate transformation, as well as the NAD/sup +//NADH interconversion, and demonstrates the usefulness of the single-crystal neutron diffraction method for determining the absolute configuration of molecules having a chiral monodeuteriomethylene group.

  17. Fact #728: May 21, 2012 Average Trip Length is Less Than Ten Miles

    Broader source: Energy.gov [DOE]

    The average trip length (one-way) is 9.7 miles according to the 2009 Nationwide Personal Transportation Survey. Trip lengths vary by the purpose of the trip. Shopping and family/personal business...

  18. Fact #693: September 19, 2011 Average Vehicle Footprint for Cars and Light Trucks

    Broader source: Energy.gov [DOE]

    A vehicle footprint is the area defined by the four points where the tires touch the ground. It is calculated as the product of the wheelbase and the average track width of the vehicle. The...

  19. Fact #870: April 27, 2015 Corporate Average Fuel Economy Progress, 1978-2014

    Broader source: Energy.gov [DOE]

    The Corporate Average Fuel Economy (CAFE) is the sales-weighted harmonic mean fuel economy of a manufacturer’s fleet of new cars or light trucks in a certain model year (MY). First enacted by...

  20. Variation in the annual average radon concentration measured in homes in Mesa County, Colorado

    SciTech Connect (OSTI)

    Rood, A.S.; George, J.L.; Langner, G.H. Jr.

    1990-04-01

    The purpose of this study is to examine the variability in the annual average indoor radon concentration. The TMC has been collecting annual average radon data for the past 5 years in 33 residential structures in Mesa County, Colorado. This report is an interim report that presents the data collected up to the present. Currently, the plans are to continue this study in the future. 62 refs., 3 figs., 12 tabs.

  1. Fact #910: February 1, 2016 Study Shows Average Cost of Electric Vehicle

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Charger Installations | Department of Energy 0: February 1, 2016 Study Shows Average Cost of Electric Vehicle Charger Installations Fact #910: February 1, 2016 Study Shows Average Cost of Electric Vehicle Charger Installations SUBSCRIBE to the Fact of the Week The EV Project and the ChargePoint America project were conducted for the Department of Energy by Idaho National Laboratory (INL). From 2011-2013 the project installed nearly 17,000 alternating current (AC) Level 2 charging stations

  2. Table 2. Value and average value of photovoltaic module shipments, 2014

    U.S. Energy Information Administration (EIA) Indexed Site

    Value and average value of photovoltaic module shipments, 2014" "Module value, total shipments (thousand dollars)" "Total Modules ",5425417 "Module average value (dollars per peak watt)" "Total Modules ",0.87 "Source: U.S. Energy Information Administration, Form EIA-63B, 'Annual Photovoltaic Cell/Module Shipments Report' Note: Dollars are not adjusted for inflation.

  3. Reliability of oceanic heat flow averages (Journal Article) | SciTech

    Office of Scientific and Technical Information (OSTI)

    Connect Reliability of oceanic heat flow averages Citation Details In-Document Search Title: Reliability of oceanic heat flow averages One of the major problems in the use of heat flow data in a quantitative manner has been the variability of closely spaced measurements. It is suggested that this variability is directly related to hydrothermal circulation in an ''effectively permeable'' oceanic crust. As a consequence, only where this crust is sealed from the seawater by an extensive and

  4. Maximum likelihood Bayesian model averaging and its predictive analysis for groundwater reactive transport models

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Lu, Dan; Ye, Ming; Curtis, Gary P.

    2015-08-01

    While Bayesian model averaging (BMA) has been widely used in groundwater modeling, it is infrequently applied to groundwater reactive transport modeling because of multiple sources of uncertainty in the coupled hydrogeochemical processes and because of the long execution time of each model run. To resolve these problems, this study analyzed different levels of uncertainty in a hierarchical way, and used the maximum likelihood version of BMA, i.e., MLBMA, to improve the computational efficiency. Our study demonstrates the applicability of MLBMA to groundwater reactive transport modeling in a synthetic case in which twenty-seven reactive transport models were designed to predict themore » reactive transport of hexavalent uranium (U(VI)) based on observations at a former uranium mill site near Naturita, CO. Moreover, these reactive transport models contain three uncertain model components, i.e., parameterization of hydraulic conductivity, configuration of model boundary, and surface complexation reactions that simulate U(VI) adsorption. These uncertain model components were aggregated into the alternative models by integrating a hierarchical structure into MLBMA. The modeling results of the individual models and MLBMA were analyzed to investigate their predictive performance. The predictive logscore results show that MLBMA generally outperforms the best model, suggesting that using MLBMA is a sound strategy to achieve more robust model predictions relative to a single model. MLBMA works best when the alternative models are structurally distinct and have diverse model predictions. When correlation in model structure exists, two strategies were used to improve predictive performance by retaining structurally distinct models or assigning smaller prior model probabilities to correlated models. Since the synthetic models were designed using data from the Naturita site, the results of this study are expected to provide guidance for real-world modeling. Finally

  5. Maximum likelihood Bayesian model averaging and its predictive analysis for groundwater reactive transport models

    SciTech Connect (OSTI)

    Lu, Dan; Ye, Ming; Curtis, Gary P.

    2015-08-01

    While Bayesian model averaging (BMA) has been widely used in groundwater modeling, it is infrequently applied to groundwater reactive transport modeling because of multiple sources of uncertainty in the coupled hydrogeochemical processes and because of the long execution time of each model run. To resolve these problems, this study analyzed different levels of uncertainty in a hierarchical way, and used the maximum likelihood version of BMA, i.e., MLBMA, to improve the computational efficiency. Our study demonstrates the applicability of MLBMA to groundwater reactive transport modeling in a synthetic case in which twenty-seven reactive transport models were designed to predict the reactive transport of hexavalent uranium (U(VI)) based on observations at a former uranium mill site near Naturita, CO. Moreover, these reactive transport models contain three uncertain model components, i.e., parameterization of hydraulic conductivity, configuration of model boundary, and surface complexation reactions that simulate U(VI) adsorption. These uncertain model components were aggregated into the alternative models by integrating a hierarchical structure into MLBMA. The modeling results of the individual models and MLBMA were analyzed to investigate their predictive performance. The predictive logscore results show that MLBMA generally outperforms the best model, suggesting that using MLBMA is a sound strategy to achieve more robust model predictions relative to a single model. MLBMA works best when the alternative models are structurally distinct and have diverse model predictions. When correlation in model structure exists, two strategies were used to improve predictive performance by retaining structurally distinct models or assigning smaller prior model probabilities to correlated models. Since the synthetic models were designed using data from the Naturita site, the results of this study are expected to provide guidance for real-world modeling. Finally, limitations of

  6. Revision of the Branch Technical Position on Concentration Averaging and Encapsulation - 12510

    SciTech Connect (OSTI)

    Heath, Maurice; Kennedy, James E.; Ridge, Christianne; Lowman, Donald [U.S. NRC, Washington, DC, 20555-0001 (United States); Cochran, John [Sandia National Laboratory (United States)

    2012-07-01

    The U.S. Nuclear Regulatory Commission (NRC) regulation governing low-level waste (LLW) disposal, 'Licensing Requirements for Land Disposal of Radioactive Waste', 10 CFR Part 61, establishes a waste classification system based on the concentration of specific radionuclides contained in the waste. The regulation also states, at 10 CFR 61.55(a)(8), that, 'the concentration of a radionuclide (in waste) may be averaged over the volume of the waste, or weight of the waste if the units are expressed as nanocuries per gram'. The NRC's Branch Technical Position on Concentration Averaging and Encapsulation provides guidance on averaging radionuclide concentrations in waste under 10 CFR 61.55(a)(8) when classifying waste for disposal. In 2007, the NRC staff proposed to revise the Branch Technical Position on Concentration Averaging and Encapsulation. The Branch Technical Position on Concentration Averaging and Encapsulation is an NRC guidance document for averaging and classifying wastes under 10 CFR 61. The Branch Technical Position on Concentration Averaging and Encapsulation is used by nuclear power plants (NPPs) licensees and sealed source users, among others. In addition, three of the four U.S. LLW disposal facility operators are required to honor the Branch Technical Position on Concentration Averaging and Encapsulation as a licensing condition. In 2010, the Commission directed the staff to develop guidance regarding large scale blending of similar homogenous waste types, as described in SECY-10-0043 as part of its Branch Technical Position on Concentration Averaging and Encapsulation revision. The Commission is improving the regulatory approach used in the Branch Technical Position on Concentration Averaging and Encapsulation by moving towards a making it more risk-informed and performance-based approach, which is more consistent with the agency's regulatory policies. Among the improvements to the Branch Technical Position on Concentration Averaging and Encapsulation

  7. Online, absolute quantitation of propranolol from spatially distinct 20-μm and 40-μm dissections of brain, liver, and kidney thin tissue sections by laser microdissection – liquid vortex capture – mass spectrometry

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Kertesz, Vilmos; Vavrek, Marissa; Freddo, Carol; Van Berkel, Gary J.; Cahill, John F.; Weiskittel, Taylor M.

    2016-05-23

    Here, spatial resolved quantitation of chemical species in thin tissue sections by mass spectrometric methods has been constrained by the need for matrix-matched standards or other arduous calibration protocols and procedures to mitigate matrix effects (e.g., spatially varying ionization suppression). Reported here is the use of laser cut and drop sampling with a laser microdissection-liquid vortex capture electrospray ionization tandem mass spectrometry (LMD-LVC/ESI-MS/MS) system for online and absolute quantitation of propranolol in mouse brain, kidney, and liver thin tissue sections of mice administered with the drug at a 7.5 mg/kg dose, intravenously. In this procedure either 20 μm x 20more » μm or 40 μm x 40 μm tissue microdissections were cut and dropped into the flowing solvent of the capture probe. During transport to the ESI source drug related material was completely extracted from the tissue into the solvent, which contained a known concentration of propranolol-d7 as an internal standard. This allowed absolute quantitation to be achieved with an external calibration curve generated from standards containing the same fixed concentration of propranolold-d7 and varied concentrations of propranolol. Average propranolol concentrations determined with the laser cut and drop sampling method closely agreed with concentration values obtained from 2.3 mm diameter tissue punches from serial sections that were extracted and quantified by HPLC/ESI-MS/MS measurements. In addition, the relative abundance of hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous findings.« less

  8. A strict test of stellar evolution models: The absolute dimensions of the massive benchmark eclipsing binary V578 Mon

    SciTech Connect (OSTI)

    Garcia, E. V.; Stassun, Keivan G.; Pavlovski, K.; Hensberge, H.; Chew, Y. Gmez Maqueo; Claret, A.

    2014-09-01

    We determine the absolute dimensions of the eclipsing binary V578 Mon, a detached system of two early B-type stars (B0V + B1V, P = 2.40848 days) in the star-forming region NGC 2244 of the Rosette Nebula. From the light curve analysis of 40 yr of photometry and the analysis of HERMES spectra, we find radii of 5.41 0.04 R{sub ?} and 4.29 0.05 R{sub ?}, and temperatures of 30,000 500 K and 25,750 435 K, respectively. We find that our disentangled component spectra for V578 Mon agree well with previous spectral disentangling from the literature. We also reconfirm the previous spectroscopic orbit of V578 Mon finding that masses of 14.54 0.08 M{sub ?} and 10.29 0.06 M{sub ?} are fully compatible with the new analysis. We compare the absolute dimensions to the rotating models of the Geneva and Utrecht groups and the models of the Granada group. We find that all three sets of models marginally reproduce the absolute dimensions of both stars with a common age within the uncertainty for gravity-effective temperature isochrones. However, there are some apparent age discrepancies for the corresponding mass-radius isochrones. Models with larger convective overshoot, >0.35, worked best. Combined with our previously determined apsidal motion of 0.07089{sub ?0.00013}{sup +0.00021} deg cycle{sup 1}, we compute the internal structure constants (tidal Love number) for the Newtonian and general relativistic contribution to the apsidal motion as log k {sub 2} = 1.975 0.017 and log k {sub 2} = 3.412 0.018, respectively. We find the relativistic contribution to the apsidal motion to be small, <4%. We find that the prediction of log k {sub 2,theo} = 2.005 0.025 of the Granada models fully agrees with our observed log k {sub 2}.

  9. Reconstruction of ionization probabilities from spatially averaged data in N dimensions

    SciTech Connect (OSTI)

    Strohaber, J.; Kolomenskii, A. A.; Schuessler, H. A.

    2010-07-15

    We present an analytical inversion technique, which can be used to recover ionization probabilities from spatially averaged data in an N-dimensional detection scheme. The solution is given as a power series in intensity. For this reason, we call this technique a multiphoton expansion (MPE). The MPE formalism was verified with an exactly solvable inversion problem in two dimensions, and probabilities in the postsaturation region, where the intensity-selective scanning approach breaks down, were recovered. In three dimensions, ionization probabilities of Xe were successfully recovered with MPE from simulated (using the Ammosov-Delone-Krainov tunneling theory) ion yields. Finally, we tested our approach with intensity-resolved benzene-ion yields, which show a resonant multiphoton ionization process. By applying MPE to this data (which were artificially averaged), the resonant structure was recovered, which suggests that the resonance in benzene may have been observed in spatially averaged data taken elsewhere.

  10. Comparison of average and point capillary pressure-saturation functions determined by steady-state centrifugation

    SciTech Connect (OSTI)

    Cropper, Clark; Perfect, Edmund; van den Berg, Dr. Elmer; Mayes, Melanie

    2010-01-01

    The capillary pressure-saturation function can be determined from centrifuge drainage experiments. In soil physics, the data resulting from such experiments are usually analyzed by the 'averaging method.' In this approach, average relative saturation, , is expressed as a function of average capillary pressure, <{psi}>, i.e., (<{psi}>). In contrast, the capillary pressure-saturation function at a physical point, i.e., S({psi}), has been extracted from similar experiments in petrophysics using the 'integral method.' The purpose of this study was to introduce the integral method applied to centrifuge experiments to a soil physics audience and to compare S({psi}) and (<{psi}>) functions, as parameterized by the Brooks-Corey and van Genuchten equations, for 18 samples drawn from a range of porous media (i.e., Berea sandstone, glass beads, and Hanford sediments). Steady-state centrifuge experiments were performed on preconsolidated samples with a URC-628 Ultra-Rock Core centrifuge. The angular velocity and outflow data sets were then analyzed using both the averaging and integral methods. The results show that the averaging method smoothes out the drainage process, yielding less steep capillary pressure-saturation functions relative to the corresponding point-based curves. Maximum deviations in saturation between the two methods ranged from 0.08 to 0.28 and generally occurred at low suctions. These discrepancies can lead to inaccurate predictions of other hydraulic properties such as the relative permeability function. Therefore, we strongly recommend use of the integral method instead of the averaging method when determining the capillary pressure-saturation function by steady-state centrifugation. This method can be successfully implemented using either the van Genuchten or Brooks-Corey functions, although the latter provides a more physically precise description of air entry at a physical point.

  11. Table HC1.1.2 Housing Unit Characteristics by Average Floorspace, 2005

    U.S. Energy Information Administration (EIA) Indexed Site

    2 Housing Unit Characteristics by Average Floorspace, 2005 " ,,"Average Square Feet per--" ," Housing Units (millions)" ,,"Housing Unit",,,"Household Member" "Housing Unit Characteristics",,"Total1","Heated","Cooled","Total","Heated","Cooled" "Total",111.1,2171,1618,1031,845,630,401 "Census Region and Division" "Northeast",20.6,2334,1664,562,911,649,220

  12. Table HC1.1.4 Housing Unit Characteristics by Average Floorspace--Apartments, 2

    U.S. Energy Information Administration (EIA) Indexed Site

    4 Housing Unit Characteristics by Average Floorspace--Apartments, 2005" ,,,"Average Square Feet per Apartment in a --" ," Housing Units (millions)" ,,,"2 to 4 Unit Building",,,"5 or More Unit Building" ,,"Apartments (millions)" "Housing Unit Characteristics",,,"Total","Heated","Cooled","Total","Heated","Cooled" "Total",111.1,24.5,1090,902,341,872,780,441

  13. Table HC1.2.4 Living Space Characteristics by Average Floorspace--Apartments, 2

    U.S. Energy Information Administration (EIA) Indexed Site

    2.4 Living Space Characteristics by Average Floorspace--Apartments, 2005" ,,,"Average Square Feet per Apartment in a --" ," Housing Units (millions)" ,,,"2 to 4 Unit Building",,,"5 or More Unit Building" ,,"Apartments (millions)" "Living Space Characteristics",,,"Total","Heated","Cooled","Total","Heated","Cooled" "Total",111.1,24.5,1090,902,341,872,780,441

  14. Performance and production requirements for the optical components in a high-average-power laser system

    SciTech Connect (OSTI)

    Chow, R.; Doss, F.W.; Taylor, J.R.; Wong, J.N.

    1999-07-02

    Optical components needed for high-average-power lasers, such as those developed for Atomic Vapor Laser Isotope Separation (AVLIS), require high levels of performance and reliability. Over the past two decades, optical component requirements for this purpose have been optimized and performance and reliability have been demonstrated. Many of the optical components that are exposed to the high power laser light affect the quality of the beam as it is transported through the system. The specifications for these optics are described including a few parameters not previously reported and some component manufacturing and testing experience. Key words: High-average-power laser, coating efficiency, absorption, optical components

  15. Builds in U.S. natural gas storage running above five-year average

    U.S. Energy Information Administration (EIA) Indexed Site

    Builds in U.S. natural gas storage running above five-year average The amount of natural gas put into underground storage since the beginning of the so-called "injection season" in April has been above the five-year average by a wide margin. In its new forecast, the U.S. Energy Information Administration said natural gas inventories, which are running more than 50% above year ago levels, are on track to reach almost 4 trillion cubic feet by the end of October which marks the start of

  16. ,"Sulfur Content, Weighted Average Refinery Crude Oil Input Qualities"

    U.S. Energy Information Administration (EIA) Indexed Site

    Sulfur Content, Weighted Average Refinery Crude Oil Input Qualities" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","Sulfur Content, Weighted Average Refinery Crude Oil Input Qualities",16,"Monthly","6/2016","1/15/1985" ,"Release Date:","8/31/2016" ,"Next Release

  17. The U.S. average retail price for on-highway diesel fuel rose this week

    U.S. Energy Information Administration (EIA) Indexed Site

    The U.S. average retail price for on-highway diesel fuel rose this week The U.S. average retail price for on-highway diesel fuel rose slightly to $3.90 a gallon on Monday. That's up 8-tenths of a penny from a week ago, based on the weekly price survey by the U.S. Energy Information Administration. Diesel prices were highest in the New England region, at 4.16 a gallon, down a penny from a week ago. Prices were lowest in the Rocky Mountain States at $3.68 a gallon, down 1.7

  18. The U.S. average retail price for on-highway diesel fuel rose this week

    U.S. Energy Information Administration (EIA) Indexed Site

    The U.S. average retail price for on-highway diesel fuel rose this week The U.S. average retail price for on-highway diesel fuel rose to $3.93 a gallon on Monday. That's up 2 ½ cents from a week ago, based on the weekly price survey by the U.S. Energy Information Administration. Prices increased in all regions across the U.S. The highest prices were found in the New England region, at 4.18 a gallon, up 2.3 cents from a week ago. Prices were lowest in the Rocky Mountain States at $3.74 a gallon,

  19. U.S. diesel prices decrease … U.S. average still over $4

    U.S. Energy Information Administration (EIA) Indexed Site

    U.S. diesel prices decrease - U.S. average still over $4 The U.S. average retail price for on-highway diesel fuel fell to $4.02 a gallon. That's down a tenth of a penny from a week ago, based on the weekly price survey by the U.S. Energy Information Administration. Diesel prices were highest in the New England region at 4.39 a gallon, up 3-tenths of a penny from a week ago. Prices were lowest in the Gulf Coast states at 3.79 a gallon, down 1.3 cents.

  20. U.S. diesel prices decrease … U.S. average still over $4

    U.S. Energy Information Administration (EIA) Indexed Site

    U.S. diesel prices decrease - U.S. average still over $4 The U.S. average retail price for on-highway diesel fuel fell to $4.00 a gallon. That's down 1.8 cents from a week ago, based on the weekly price survey by the U.S. Energy Information Administration. Diesel prices were highest in the New England region and Central Atlantic states at 4.31 a gallon, down 4.9 and 3.9 cents, respectively, from a week ago. Prices were lowest in the Gulf Coast states at 3.80 a gallon, down 1.1 cents.

  1. U.S. diesel prices increase … U.S. average still over $4

    U.S. Energy Information Administration (EIA) Indexed Site

    U.S. diesel prices increase - U.S. average still over $4 The U.S. average retail price for on-highway diesel fuel rose to $4.02 a gallon. That's up half a penny from a week ago, based on the weekly price survey by the U.S. Energy Information Administration. Diesel prices were highest in the New England region at 4.36 a gallon, down 2.7 cents from a week ago. Prices were lowest in the Gulf Coast states at 3.81 a gallon, up 2.1 cents.

  2. Solid-state track recorder dosimetry device to measure absolute reaction rates and neutron fluence as a function of time

    DOE Patents [OSTI]

    Gold, Raymond; Roberts, James H.

    1989-01-01

    A solid state track recording type dosimeter is disclosed to measure the time dependence of the absolute fission rates of nuclides or neutron fluence over a period of time. In a primary species an inner recording drum is rotatably contained within an exterior housing drum that defines a series of collimating slit apertures overlying windows defined in the stationary drum through which radiation can enter. Film type solid state track recorders are positioned circumferentially about the surface of the internal recording drum to record such radiation or its secondary products during relative rotation of the two elements. In another species both the recording element and the aperture element assume the configuration of adjacent disks. Based on slit size of apertures and relative rotational velocity of the inner drum, radiation parameters within a test area may be measured as a function of time and spectra deduced therefrom.

  3. Fact #851 December 15, 2014 The Average Number of Gears used...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Average Number of Gears in New Cars and Light Trucks Model Year Gears 1980 3.5 1981 3.5 1982 3.6 1983 3.7 1984 3.7 1985 3.8 1986 3.8 1987 3.9 1988 3.9 1989 3.9 1990 4.0 1991 4.0 ...

  4. Development of a high average current polarized electron source with long cathode operational lifetime

    SciTech Connect (OSTI)

    C. K. Sinclair; P. A. Adderley; B. M. Dunham; J. C. Hansknecht; P. Hartmann; M. Poelker; J. S. Price; P. M. Rutt; W. J. Schneider; M. Steigerwald

    2007-02-01

    Substantially more than half of the electromagnetic nuclear physics experiments conducted at the Continuous Electron Beam Accelerator Facility of the Thomas Jefferson National Accelerator Facility (Jefferson Laboratory) require highly polarized electron beams, often at high average current. Spin-polarized electrons are produced by photoemission from various GaAs-based semiconductor photocathodes, using circularly polarized laser light with photon energy slightly larger than the semiconductor band gap. The photocathodes are prepared by activation of the clean semiconductor surface to negative electron affinity using cesium and oxidation. Historically, in many laboratories worldwide, these photocathodes have had short operational lifetimes at high average current, and have often deteriorated fairly quickly in ultrahigh vacuum even without electron beam delivery. At Jefferson Lab, we have developed a polarized electron source in which the photocathodes degrade exceptionally slowly without electron emission, and in which ion back bombardment is the predominant mechanism limiting the operational lifetime of the cathodes during electron emission. We have reproducibly obtained cathode 1/e dark lifetimes over two years, and 1/e charge density and charge lifetimes during electron beam delivery of over 2?105???C/cm2 and 200 C, respectively. This source is able to support uninterrupted high average current polarized beam delivery to three experimental halls simultaneously for many months at a time. Many of the techniques we report here are directly applicable to the development of GaAs photoemission electron guns to deliver high average current, high brightness unpolarized beams.

  5. A Code to Produce Cell Averaged Cross Sections for Fast Critical Assemblies and Fast Power Reactors.

    Energy Science and Technology Software Center (OSTI)

    1987-05-14

    Version 00 SLAROM solves the neutron integral transport equations to determine the flux distribution and spectra in a fast reactor lattice and calculates cell averaged effective cross sections. The code uses multigroup data of the type in DLC-111/JFS that use Bondarenko factors for resonance effects.

  6. New Jersey Average Price of Natural Gas Delivered to Residential and

    U.S. Energy Information Administration (EIA) Indexed Site

    Commercial Consumers by Local Distribution and Mark 6.55 6.86 8.24 8.99 9.49 10.78 1989-2016 Commercial Average Price 7.76 7.66 7.50 6.80 7.15 7.72

  7. New York Average Price of Natural Gas Delivered to Residential and

    U.S. Energy Information Administration (EIA) Indexed Site

    Commercial Consumers by Local Distribution and Market 10.31 9.45 9.65 9.90 10.91 14.77 1989-2016 Commercial Average Price 6.59 6.58 6.40 6.23 5.99 5.76

  8. Ohio Average Price of Natural Gas Delivered to Residential and Commercial

    U.S. Energy Information Administration (EIA) Indexed Site

    Consumers by Local Distribution and Marketers 6.48 6.44 7.16 8.01 11.73 19.29 1989-2016 Commercial Average Price 5.32 5.30 5.31 5.38 6.17 7.03

  9. District of Columbia Average Price of Natural Gas Delivered to Residential

    U.S. Energy Information Administration (EIA) Indexed Site

    and Commercial Consumers by Local Distributio 9.96 9.53 10.72 10.55 12.56 15.35 1989-2016 Commercial Average Price 9.50 9.30 10.21 10.24 10.24 11.31

  10. SU-E-T-174: Evaluation of the Optimal Intensity Modulated Radiation Therapy Plans Done On the Maximum and Average Intensity Projection CTs

    SciTech Connect (OSTI)

    Jurkovic, I; Stathakis, S; Li, Y; Patel, A; Vincent, J; Papanikolaou, N; Mavroidis, P

    2014-06-01

    Purpose: To determine the difference in coverage between plans done on average intensity projection and maximum intensity projection CT data sets for lung patients and to establish correlations between different factors influencing the coverage. Methods: For six lung cancer patients, 10 phases of equal duration through the respiratory cycle, the maximum and average intensity projections (MIP and AIP) from their 4DCT datasets were obtained. MIP and AIP datasets had three GTVs delineated (GTVaip — delineated on AIP, GTVmip — delineated on MIP and GTVfus — delineated on each of the 10 phases and summed up). From the each GTV, planning target volumes (PTV) were then created by adding additional margins. For each of the PTVs an IMRT plan was developed on the AIP dataset. The plans were then copied to the MIP data set and were recalculated. Results: The effective depths in AIP cases were significantly smaller than in MIP (p < 0.001). The Pearson correlation coefficient of r = 0.839 indicates strong degree of positive linear relationship between the average percentage difference in effective depths and average PTV coverage on the MIP data set. The V2 0 Gy of involved lung depends on the PTV coverage. The relationship between PTVaip mean CT number difference and PTVaip coverage on MIP data set gives r = 0.830. When the plans are produced on MIP and copied to AIP, r equals −0.756. Conclusion: The correlation between the AIP and MIP data sets indicates that the selection of the data set for developing the treatment plan affects the final outcome (cases with high average percentage difference in effective depths between AIP and MIP should be calculated on AIP). The percentage of the lung volume receiving higher dose depends on how well PTV is covered, regardless of on which set plan is done.

  11. Combining multi-objective optimization and bayesian model averaging to calibrate forecast ensembles of soil hydraulic models

    SciTech Connect (OSTI)

    Vrugt, Jasper A; Wohling, Thomas

    2008-01-01

    Most studies in vadose zone hydrology use a single conceptual model for predictive inference and analysis. Focusing on the outcome of a single model is prone to statistical bias and underestimation of uncertainty. In this study, we combine multi-objective optimization and Bayesian Model Averaging (BMA) to generate forecast ensembles of soil hydraulic models. To illustrate our method, we use observed tensiometric pressure head data at three different depths in a layered vadose zone of volcanic origin in New Zealand. A set of seven different soil hydraulic models is calibrated using a multi-objective formulation with three different objective functions that each measure the mismatch between observed and predicted soil water pressure head at one specific depth. The Pareto solution space corresponding to these three objectives is estimated with AMALGAM, and used to generate four different model ensembles. These ensembles are post-processed with BMA and used for predictive analysis and uncertainty estimation. Our most important conclusions for the vadose zone under consideration are: (1) the mean BMA forecast exhibits similar predictive capabilities as the best individual performing soil hydraulic model, (2) the size of the BMA uncertainty ranges increase with increasing depth and dryness in the soil profile, (3) the best performing ensemble corresponds to the compromise (or balanced) solution of the three-objective Pareto surface, and (4) the combined multi-objective optimization and BMA framework proposed in this paper is very useful to generate forecast ensembles of soil hydraulic models.

  12. Gatling gun: high average polarized current injector for eRHIC

    SciTech Connect (OSTI)

    Litvinenko, V.N.

    2010-01-01

    This idea was originally developed in 2001 for, at that time, an ERL-based (and later recirculating-ring) electron-ion collider at JLab. Naturally the same idea is applicable for any gun requiring current exceeding capability of a single cathode. ERL-based eRHIC is one of such cases. This note related to eRHIC was prepared at Duke University in February 2003. In many case photo-injectors can have a limited average current - it is especially true about polarized photo-guns. It is know that e-RHIC requires average polarized electron current well above currently demonstrated by photo-injectors - hence combining currents from multiple guns is can be useful option for eRHIC.

  13. HIGH AVERAGE CURRENT LOW EMITTANCE BEAM EMPLOYING CW NORMAL CONDUCTING GUN.

    SciTech Connect (OSTI)

    CHANG,X.; BEN-ZVI, I.; KEWISCH, J.; PAI, C.

    2007-06-25

    CW normal conducting guns usually do not achieve very high field gradient and waste much RF power at high field gradient compared to superconducting cavities. But they have less trapped modes and wakefields compared to the superconducting cavities due to their low Q. The external bucking coil can also be applied very close to the cathode to improve the beam quality. By using a low frequency gun with a recessed cathode and a carefully designed beam line we can get a high average current and a high quality beam with acceptable RF power loss on the cavity wall. This paper shows that the CW normal conducting gun can be a backup solution for those projects which need high peak and average current, low emittance electron beams such as the Relativistic Heavy Ion Collider (RHIC) e-cooling project and Energy Recovery Linac (Em) project.

  14. Energy Conservation Program for Consumer Products: Representative Average Unit Costs of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Conservation Program for Consumer Products: Representative Average Unit Costs of Energy, is a notice issued by the Department of Energy. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document."

  15. "Table A25. Average Prices of Selected Purchased Energy Sources by Census"

    U.S. Energy Information Administration (EIA) Indexed Site

    . Average Prices of Selected Purchased Energy Sources by Census" " Region, Industry Group, and Selected Industries, 1991: Part 1" " (Estimates in Dollars per Physical Unit)" ,,,,," " " "," "," ","Residual","Distillate","Natural Gas(c)"," "," ","RSE" "SIC"," ","Electricity","Fuel Oil","Fuel

  16. "Table A47. Average Prices of Purchased Electricity, Steam, and Natural Gas"

    U.S. Energy Information Administration (EIA) Indexed Site

    7. Average Prices of Purchased Electricity, Steam, and Natural Gas" " by Type of Supplier, Census Region, Industry Group, and Selected Industries," 1991 " (Estimates in Dollars per Physical Units)" ,," Electricity",," Steam",," Natural Gas" ,," (million kWh)",," (Billion BTU)",," (1000 cu ft)" ,"

  17. "Table E8.2. Average Prices of Selected Purchased Energy Sources, 1998;"

    U.S. Energy Information Administration (EIA) Indexed Site

    2. Average Prices of Selected Purchased Energy Sources, 1998;" " Level: National and Regional Data; " " Row: Values of Shipments and Employment Sizes;" " Column: Energy Sources;" " Unit: U.S. Dollars per Million Btu." " ",," "," ",," "," ","RSE" "Economic",,"Residual","Distillate",,"LPG and",,"Row"

  18. Coupling of an average-atom model with a collisional-radiative equilibrium model

    SciTech Connect (OSTI)

    Faussurier, G. Blancard, C.; Cossé, P.

    2014-11-15

    We present a method to combine a collisional-radiative equilibrium model and an average-atom model to calculate bound and free electron wavefunctions in hot dense plasmas by taking into account screening. This approach allows us to calculate electrical resistivity and thermal conductivity as well as pressure in non local thermodynamic equilibrium plasmas. Illustrations of the method are presented for dilute titanium plasma.

  19. Table 7.1 Average Prices of Purchased Energy Sources, 2002

    U.S. Energy Information Administration (EIA) Indexed Site

    Average Prices of Purchased Energy Sources, 2002;" " Level: National and Regional Data; " " Row: NAICS Codes;" " Column: All Energy Sources Collected;" " Unit: U.S. Dollars per Physical Units." ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,"Selected Wood and Other Biomass Components" ,,,,,,"Coal Components",,,"Coke",,,"Electricity Components",,,,,,,,,,,,,,"Natural Gas Components",,,"Steam Components"

  20. Table 7.2 Average Prices of Purchased Energy Sources, 2002

    U.S. Energy Information Administration (EIA) Indexed Site

    2 Average Prices of Purchased Energy Sources, 2002;" " Level: National and Regional Data; " " Row: NAICS Codes; " " Column: All Energy Sources Collected;" " Unit: U.S. Dollars per Million Btu." ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,"Selected Wood and Other Biomass Components" ,,,,,,"Coal Components",,,"Coke",,,"Electricity Components",,,,,,,,,,,,,,"Natural Gas Components",,,"Steam Components"

  1. Table 7.2 Average Prices of Purchased Energy Sources, 2010;

    U.S. Energy Information Administration (EIA) Indexed Site

    Table 7.2 Average Prices of Purchased Energy Sources, 2010; Level: National and Regional Data; Row: NAICS Codes; Column: All Energy Sources Collected; Unit: U.S. Dollars per Million Btu. Selected Wood and Other Biomass Components Coal Components Coke Electricity Components Natural Gas Components Steam Components Total Wood Residues Bituminous Electricity Diesel Fuel Motor Natural Gas Steam and Wood-Related and Electricity from Sources and Gasoline Pulping Liquor Natural Gas from Sources Steam

  2. Table N8.2. Average Prices of Purchased Energy Sources, 1998

    U.S. Energy Information Administration (EIA) Indexed Site

    2. Average Prices of Purchased Energy Sources, 1998;" " Level: National and Regional Data; " " Row: NAICS Codes; Column: All Energy Sources Collected;" " Unit: U.S. Dollars per Million Btu." ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,"Selected","Wood and Other","Biomass","Components" ,,,,,,,"Coal Components",,,"Coke",,"Electricity","Components",,,,,,,,,,,,,"Natural

  3. Summary Notes from 3 October 2007 Generic Technical Issue Discussion on Concentration Averaging

    Office of Environmental Management (EM)

    3 October 2007 Generic Technical Issue Discussion on Concentration Averaging Attendees: Representatives from Department of Energy-Headquarters (DOE-HQ) and the U.S. Nuclear Regulatory Commission (NRC) met at the DOE offices in Germantown, Maryland on 3 October 2007. Representatives from Department of Energy-Savannah River (DOE-SR) and the South Carolina Department of Health and Environmental Control (SCDHEC) participated in the meeting via a teleconference link. Discussion: DOE believes that

  4. Picosecond Pulse Recirculation for High Average Brightness Thomson Scattering-based Gamma-ray Sources

    SciTech Connect (OSTI)

    Semenov, V. A.

    2009-06-12

    Pulse recirculation has been successfully demonstrated with the interaction laser system of LLNL's Thomson-Radiated Extreme X-ray (T-REX) source. The recirculation increased twenty-eight times the intensity of the light coming out of the laser system, demonstrating the capability of increasing the gamma-ray flux emitted by T-REX. The technical approach demonstrated could conceivably increase the average gamma-ray flux output by up to a hundred times.

  5. Contributed Review: Absolute spectral radiance calibration of fiber-optic shock-temperature pyrometers using a coiled-coil irradiance standard lamp

    SciTech Connect (OSTI)

    Fat’yanov, O. V. Asimow, P. D.

    2015-10-15

    We describe an accurate and precise calibration procedure for multichannel optical pyrometers such as the 6-channel, 3-ns temporal resolution instrument used in the Caltech experimental geophysics laboratory. We begin with a review of calibration sources for shock temperatures in the 3000-30 000 K range. High-power, coiled tungsten halogen standards of spectral irradiance appear to be the only practical alternative to NIST-traceable tungsten ribbon lamps, which are no longer available with large enough calibrated area. However, non-uniform radiance complicates the use of such coiled lamps for reliable and reproducible calibration of pyrometers that employ imaging or relay optics. Careful analysis of documented methods of shock pyrometer calibration to coiled irradiance standard lamps shows that only one technique, not directly applicable in our case, is free of major radiometric errors. We provide a detailed description of the modified Caltech pyrometer instrument and a procedure for its absolute spectral radiance calibration, accurate to ±5%. We employ a designated central area of a 0.7× demagnified image of a coiled-coil tungsten halogen lamp filament, cross-calibrated against a NIST-traceable tungsten ribbon lamp. We give the results of the cross-calibration along with descriptions of the optical arrangement, data acquisition, and processing. We describe a procedure to characterize the difference between the static and dynamic response of amplified photodetectors, allowing time-dependent photodiode correction factors for spectral radiance histories from shock experiments. We validate correct operation of the modified Caltech pyrometer with actual shock temperature experiments on single-crystal NaCl and MgO and obtain very good agreement with the literature data for these substances. We conclude with a summary of the most essential requirements for error-free calibration of a fiber-optic shock-temperature pyrometer using a high-power coiled tungsten halogen

  6. Coherent radar estimates of average high-latitude ionospheric Joule heating

    SciTech Connect (OSTI)

    Kosch, M.J.; Nielsen, E.

    1995-07-01

    The Scandinavian Twin Auroral Radar Experiment (STARE) and Sweden and Britain Radar Experiment (SABRE) bistatic coherent radar systems have been employed to estimate the spatial and temporal variation of the ionospheric Joule heating in the combined geographic latitude range 63.8 deg - 72.6 deg (corrected geomagnetic latitude 61.5 deg - 69.3 deg) over Scandinavia. The 173 days of good observations with all four radars have been analyzed during the period 1982 to 1986 to estimate the average ionospheric electric field versus time and latitude. The AE dependent empirical model of ionospheric Pedersen conductivity of Spiro et al. (1982) has been used to calculate the Joule heating. The latitudinal and diurnal variation of Joule heating as well as the estimated mean hemispherical heating of 1.7 x 10(exp 11) W are in good agreement with earlier results. Average Joule heating was found to vary linearly with the AE, AU, and AL indices and as a second-order power law with Kp. The average Joule heating was also examined as a function of the direction and magnitude of the interplanetary magnetic field. It has been shown for the first time that the ionospheric electric field magnitude as well as the Joule heating increase with increasingly negative (southward) Bz.

  7. Analytical gradients of the state-average complete active space self-consistent field method with density fitting

    SciTech Connect (OSTI)

    Delcey, Mickaël G.; Pedersen, Thomas Bondo; Aquilante, Francesco; Lindh, Roland

    2015-07-28

    An efficient implementation of the state-averaged complete active space self-consistent field (SA-CASSCF) gradients employing density fitting (DF) is presented. The DF allows a reduction both in scaling and prefactors of the different steps involved. The performance of the algorithm is demonstrated on a set of molecules ranging up to an iron-Heme b complex which with its 79 atoms and 811 basis functions is to our knowledge the largest SA-CASSCF gradient computed. For smaller systems where the conventional code could still be used as a reference, both the linear response calculation and the gradient formation showed a clear timing reduction and the overall cost of a geometry optimization is typically reduced by more than one order of magnitude while the accuracy loss is negligible.

  8. Absolute cavity pyrgeometer

    DOE Patents [OSTI]

    Reda, Ibrahim

    2013-10-29

    Implementations of the present disclosure involve an apparatus and method to measure the long-wave irradiance of the atmosphere or long-wave source. The apparatus may involve a thermopile, a concentrator and temperature controller. The incoming long-wave irradiance may be reflected from the concentrator to a thermopile receiver located at the bottom of the concentrator to receive the reflected long-wave irradiance. In addition, the thermopile may be thermally connected to a temperature controller to control the device temperature. Through use of the apparatus, the long-wave irradiance of the atmosphere may be calculated from several measurements provided by the apparatus. In addition, the apparatus may provide an international standard of pyrgeometers' calibration that is traceable back to the International System of Units (SI) rather than to a blackbody atmospheric simulator.

  9. Absolute Time-Resolved Emission of Non-LTE L-Shell Spectra from Ti-Doped Aerogels

    SciTech Connect (OSTI)

    Back,C.; Feldman, U.; Weaver, J.; Seely, J.; Constantin, C.; Holland, G.; Lee, R.; Chung, H.; Scott, H.

    2006-01-01

    Outstanding discrepancies between data and calculations of laser-produced plasmas in recombination have been observed since the 1980s. Although improvements in hydrodynamic modeling may reduce the discrepancies, there are indications that non-LTE atomic kinetics may be the dominant cause. Experiments to investigate non-LTE effects were recently performed at the NIKE KrF laser on low-density Ti-doped aerogels. The laser irradiated a 2 mm diameter, cylindrical sample of various lengths with a 4-ns square pulse to create a volumetrically heated plasma. Ti L-shell spectra spanning a range of 0.47-3 keV were obtained with a transmission grating coupled to Si photodiodes. The diagnostic can be configured to provide 1-dimensional spatial resolution at a single photon energy, or 18 discrete energies with a resolving power, {gamma}/{delta}{gamma} of 3-20. The data are examined and compared to calculations to develop absolute emission measurements that can provide new tests of the non-LTE physics.

  10. DAQ Software Contributions, Absolute Scale Energy Calibration and Background Evaluation for the NOvA Experiment at Fermilab

    SciTech Connect (OSTI)

    Flumerfelt, Eric Lewis

    2015-08-01

    The NOvA (NuMI Off-axis ve [nu_e] Appearance) Experiment is a long-baseline accelerator neutrino experiment currently in its second year of operations. NOvA uses the Neutrinos from the Main Injector (NuMI) beam at Fermilab, and there are two main off-axis detectors: a Near Detector at Fermilab and a Far Detector 810 km away at Ash River, MN. The work reported herein is in support of the NOvA Experiment, through contributions to the development of data acquisition software, providing an accurate, absolute-scale energy calibration for electromagnetic showers in NOvA detector elements, crucial to the primary electron neutrino search, and through an initial evaluation of the cosmic background rate in the NOvA Far Detector, which is situated on the surface without significant overburden. Additional support work for the NOvA Experiment is also detailed, including DAQ Server Administration duties and a study of NOvA’s sensitivity to neutrino oscillations into a “sterile” state.