Sample records for automated distributed generation

  1. Integrated, Automated Distributed Generation Technologies Demonstration

    SciTech Connect (OSTI)

    Jensen, Kevin

    2014-09-30T23:59:59.000Z

    The purpose of the NETL Project was to develop a diverse combination of distributed renewable generation technologies and controls and demonstrate how the renewable generation could help manage substation peak demand at the ATK Promontory plant site. The Promontory plant site is located in the northwestern Utah desert approximately 25 miles west of Brigham City, Utah. The plant encompasses 20,000 acres and has over 500 buildings. The ATK Promontory plant primarily manufactures solid propellant rocket motors for both commercial and government launch systems. The original project objectives focused on distributed generation; a 100 kW (kilowatt) wind turbine, a 100 kW new technology waste heat generation unit, a 500 kW energy storage system, and an intelligent system-wide automation system to monitor and control the renewable energy devices then release the stored energy during the peak demand time. The original goal was to reduce peak demand from the electrical utility company, Rocky Mountain Power (RMP), by 3.4%. For a period of time we also sought to integrate our energy storage requirements with a flywheel storage system (500 kW) proposed for the Promontory/RMP Substation. Ultimately the flywheel storage system could not meet our project timetable, so the storage requirement was switched to a battery storage system (300 kW.) A secondary objective was to design/install a bi-directional customer/utility gateway application for real-time visibility and communications between RMP, and ATK. This objective was not achieved because of technical issues with RMP, ATK Information Technology Department’s stringent requirements based on being a rocket motor manufacturing facility, and budget constraints. Of the original objectives, the following were achieved: • Installation of a 100 kW wind turbine. • Installation of a 300 kW battery storage system. • Integrated control system installed to offset electrical demand by releasing stored energy from renewable sources during peak hours of the day. Control system also monitors the wind turbine and battery storage system health, power output, and issues critical alarms. Of the original objectives, the following were not achieved: • 100 kW new technology waste heat generation unit. • Bi-directional customer/utility gateway for real time visibility and communications between RMP and ATK. • 3.4% reduction in peak demand. 1.7% reduction in peak demand was realized instead.

  2. Automated di/dt Stressmark Generation for Microprocessor Power Distribution Networks

    E-Print Network [OSTI]

    John, Lizy Kurian

    Automated di/dt Stressmark Generation for Microprocessor Power Distribution Networks Youngtaek Kim for automated di/dt stressmark generation to test maximum voltage droop in a microprocessor power distribution and typical benchmarks in experiments covering three micro-processor architectures and five power distribution

  3. Distributed Generation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField Campaign:INEA : Papers SubfoldersU.S. RefiningDistributed EnergyUntapped

  4. A Distributed Facilities Automation System For IBM Buildings

    E-Print Network [OSTI]

    Houle, W. D. Sr.

    to the host would be via an IBM-supplied local communications network protocol. Remote appli cations would include process control, security, energy manage ment, facilities automation or any other automation application. The remote systems... of these areas which are affected are: - HVAC - Chemical Processes Control - Utilities Generation - Tank Farm Monitoring Resource Management - Solvent Supply and Recovery Systems - DI Water Distribution - Sewage and Waste Treatment Plant Control...

  5. A DISTRIBUTED AUTOMATION SYSTEM FOR ELECTROPHYSICAL INSTALLATIONS

    E-Print Network [OSTI]

    Kozak, Victor R.

    on CAMAC devices. Growing requirements to functions, parameters and reliability of automation components and distributing panels between terminal equipment and control devices implemented in CAMAC standard. For avoiding this problem there was decided to implement new devices as embedded devices into end equipment. We assumed

  6. Automated distribution scheme speeds service restoration

    SciTech Connect (OSTI)

    Atwell, E. [Lakeland Electric and Water, FL (United States)] [Lakeland Electric and Water, FL (United States); Gamvrelis, T. [Harris Canada, Inc., Calgary, Alberta (Canada). Control Div.] [Harris Canada, Inc., Calgary, Alberta (Canada). Control Div.; Kearns, D. [S and C Electric Co., Chicago, IL (United States)] [S and C Electric Co., Chicago, IL (United States); Landman, R. [H and L Instruments, North Hampton, NH (United States)] [H and L Instruments, North Hampton, NH (United States)

    1996-01-01T23:59:59.000Z

    This article describes an automated distribution scheme that met Lakeland Electric requirements for an automated scheme that would restore power to a major customer in less than 60 seconds. In January 1993, Lakeland Electric and Water (LEW) took on the design and construction of a new 12.47-kV automated distribution system for the Publix Supermarket Industrial complex. The industrial complex in Lakeland, Florida, totals 2 million square feet and houses a dairy processing plant, bakery, produce plant, deli plant, data processing facility for Publix`s entire retail network, purchasing department, as well as several maintenance facilities. The retail chain is LEW`s largest customer with a peak demand of 15.5 MW and a load factor of 81%. Publix`s rapid expansion plan has placed a great deal of pressure on this facility to perform at peak level with no interruptions of product flow. The task at hand was to provide Publix with a state-of-the-art, automated, distribution system built to withstand the inherent weather-related situations in central Florida, lightning and hurricanes.

  7. Automated FMEA based diagnostic symptom generation. Neal Snooke1,

    E-Print Network [OSTI]

    Snooke, Neal

    Automated FMEA based diagnostic symptom generation. Neal Snooke1, , Chris Price Department the model based simulation used to produce an automated Failure Modes and Effect Analysis (FMEA to automate the production of a FMEA report, and the paper also considers the relationship between FMEA

  8. CONSULTANT REPORT DISTRIBUTED GENERATION

    E-Print Network [OSTI]

    an independent cost analysis to interconnect and integrate increased penetration levels of renewable distributed costs. The Energy Commission considers this study a first step toward the 2012 Integrated Energy Policy Generation Integration Cost Study: Analytical Framework. California Energy Commission. CEC2002013007. i

  9. Renewable Energy: Distributed Generation Policies and Programs...

    Broader source: Energy.gov (indexed) [DOE]

    Energy Policies & Programs Renewable Energy: Distributed Generation Policies and Programs Renewable Energy: Distributed Generation Policies and Programs Distributed generation...

  10. GASIFICATION FOR DISTRIBUTED GENERATION

    SciTech Connect (OSTI)

    Ronald C. Timpe; Michael D. Mann; Darren D. Schmidt

    2000-05-01T23:59:59.000Z

    A recent emphasis in gasification technology development has been directed toward reduced-scale gasifier systems for distributed generation at remote sites. The domestic distributed power generation market over the next decade is expected to be 5-6 gigawatts per year. The global increase is expected at 20 gigawatts over the next decade. The economics of gasification for distributed power generation are significantly improved when fuel transport is minimized. Until recently, gasification technology has been synonymous with coal conversion. Presently, however, interest centers on providing clean-burning fuel to remote sites that are not necessarily near coal supplies but have sufficient alternative carbonaceous material to feed a small gasifier. Gasifiers up to 50 MW are of current interest, with emphasis on those of 5-MW generating capacity. Internal combustion engines offer a more robust system for utilizing the fuel gas, while fuel cells and microturbines offer higher electric conversion efficiencies. The initial focus of this multiyear effort was on internal combustion engines and microturbines as more realistic near-term options for distributed generation. In this project, we studied emerging gasification technologies that can provide gas from regionally available feedstock as fuel to power generators under 30 MW in a distributed generation setting. Larger-scale gasification, primarily coal-fed, has been used commercially for more than 50 years to produce clean synthesis gas for the refining, chemical, and power industries. Commercial-scale gasification activities are under way at 113 sites in 22 countries in North and South America, Europe, Asia, Africa, and Australia, according to the Gasification Technologies Council. Gasification studies were carried out on alfalfa, black liquor (a high-sodium waste from the pulp industry), cow manure, and willow on the laboratory scale and on alfalfa, black liquor, and willow on the bench scale. Initial parametric tests evaluated through reactivity and product composition were carried out on thermogravimetric analysis (TGA) equipment. These tests were evaluated and then followed by bench-scale studies at 1123 K using an integrated bench-scale fluidized-bed gasifier (IBG) which can be operated in the semicontinuous batch mode. Products from tests were solid (ash), liquid (tar), and gas. Tar was separated on an open chromatographic column. Analysis of the gas product was carried out using on-line Fourier transform infrared spectroscopy (FT-IR). For selected tests, gas was collected periodically and analyzed using a refinery gas analyzer GC (gas chromatograph). The solid product was not extensively analyzed. This report is a part of a search into emerging gasification technologies that can provide power under 30 MW in a distributed generation setting. Larger-scale gasification has been used commercially for more than 50 years to produce clean synthesis gas for the refining, chemical, and power industries, and it is probable that scaled-down applications for use in remote areas will become viable. The appendix to this report contains a list, description, and sources of currently available gasification technologies that could be or are being commercially applied for distributed generation. This list was gathered from current sources and provides information about the supplier, the relative size range, and the status of the technology.

  11. Scalable Distributed Automation System: Scalable Real-time Decentralized Volt/VAR Control

    SciTech Connect (OSTI)

    None

    2012-03-01T23:59:59.000Z

    GENI Project: Caltech is developing a distributed automation system that allows distributed generators—solar panels, wind farms, thermal co-generation systems—to effectively manage their own power. To date, the main stumbling block for distributed automation systems has been the inability to develop software that can handle more than 100,000 distributed generators and be implemented in real time. Caltech’s software could allow millions of generators to self-manage through local sensing, computation, and communication. Taken together, localized algorithms can support certain global objectives, such as maintaining the balance of energy supply and demand, regulating voltage and frequency, and minimizing cost. An automated, grid-wide power control system would ease the integration of renewable energy sources like solar power into the grid by quickly transmitting power when it is created, eliminating the energy loss associated with the lack of renewable energy storage capacity of the grid.

  12. automated energy distribution: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    automated energy distribution First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Automated Energy...

  13. DISTRIBUTED GENERATION AND COGENERATION POLICY

    E-Print Network [OSTI]

    Director EFFICIENCY, RENEWABLES & DEMAND ANALYSIS DIVISION B.B. Blevins Executive Director DISCLAIMER capacity targets. KEYWORDS Distributed generation, cogeneration, photovoltaics, wind, biomass, combined

  14. Distributed Generation Operational Reliability, Executive Summary...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    2004 This report summarizes the results of the project, "Distributed Generation Market Transformation Tools: Distributed Generation Reliability and Availability Database,"...

  15. Automated Formula Generation and Performance Learning for the FFT

    E-Print Network [OSTI]

    Automated Formula Generation and Performance Learning for the FFT Bryan Singer Manuela Veloso equivalent formulas. When these formulas are implemented in actual code, they often have very di erent running times. Thus, an important problem is nding a formula that implements the signal processing

  16. Automated Formula Generation and Performance Learning for the FFT

    E-Print Network [OSTI]

    Automated Formula Generation and Performance Learning for the FFT Bryan Singer Manuela Veloso equivalent formulas. When these formulas are implemented in actual code, they often have very different running times. Thus, an important problem is finding a formula that implements the signal processing

  17. Execution Trace-Driven Automated Attack Signature Generation Susanta Nanda

    E-Print Network [OSTI]

    Chiueh, Tzi-cker

    Execution Trace-Driven Automated Attack Signature Generation Susanta Nanda Symantec Research Labs In its most general form, an attack signature is a program that can correctly determine if an input network packet se- quence can successfully attack a protected network appli- cation. Filter rules used

  18. Automated gait generation based on traditional animation

    E-Print Network [OSTI]

    Lee, Sung Hwa

    2005-08-29T23:59:59.000Z

    This thesis describes the development of a tool to assist animators in doing walk cycles. In traditional animation, animators create expressive walk cycles with key poses. The process of generating walk cycles by hand is tedious and repetitive...

  19. Automated Energy Distribution and Reliability System (AEDR): Final Report

    SciTech Connect (OSTI)

    Buche, D. L.

    2008-07-01T23:59:59.000Z

    This report describes Northern Indiana Public Service Co. project efforts to develop an automated energy distribution and reliability system. The purpose of this project was to implement a database-driven GIS solution that would manage all of the company's gas, electric, and landbase objects.

  20. Use of Building Automation System Trend Data for Inputs Generation in Bottom-Up Simulation Calibration

    E-Print Network [OSTI]

    Zibin, N. F.; Zmeureanu, R. G.; Love, J. A.

    2013-01-01T23:59:59.000Z

    for analysis and use in simulation is very large. This paper explores automating the process of generating inputs from Building Automation System (BAS) trend data for use in building simulation software. A proof-of-concept prototype called the Automatic...

  1. Method and apparatus for automated, modular, biomass power generation

    DOE Patents [OSTI]

    Diebold, James P. (Lakewood, CO); Lilley, Arthur (Finleyville, PA); Browne, Kingsbury III (Golden, CO); Walt, Robb Ray (Aurora, CO); Duncan, Dustin (Littleton, CO); Walker, Michael (Longmont, CO); Steele, John (Aurora, CO); Fields, Michael (Arvada, CO); Smith, Trevor (Lakewood, CO)

    2011-03-22T23:59:59.000Z

    Method and apparatus for generating a low tar, renewable fuel gas from biomass and using it in other energy conversion devices, many of which were designed for use with gaseous and liquid fossil fuels. An automated, downdraft gasifier incorporates extensive air injection into the char bed to maintain the conditions that promote the destruction of residual tars. The resulting fuel gas and entrained char and ash are cooled in a special heat exchanger, and then continuously cleaned in a filter prior to usage in standalone as well as networked power systems.

  2. Method and apparatus for automated, modular, biomass power generation

    DOE Patents [OSTI]

    Diebold, James P; Lilley, Arthur; Browne, III, Kingsbury; Walt, Robb Ray; Duncan, Dustin; Walker, Michael; Steele, John; Fields, Michael; Smith, Trevor

    2013-11-05T23:59:59.000Z

    Method and apparatus for generating a low tar, renewable fuel gas from biomass and using it in other energy conversion devices, many of which were designed for use with gaseous and liquid fossil fuels. An automated, downdraft gasifier incorporates extensive air injection into the char bed to maintain the conditions that promote the destruction of residual tars. The resulting fuel gas and entrained char and ash are cooled in a special heat exchanger, and then continuously cleaned in a filter prior to usage in standalone as well as networked power systems.

  3. The Automated Bicron Tester: Automated electronic instrument diagnostic, testing, and alignment system with records generation

    SciTech Connect (OSTI)

    Rao, G.S.; Maddox, S.R.; Turner, G.W.; Vandermolen, R.I.

    1995-11-01T23:59:59.000Z

    The Bicron Surveyor MX is a portable radiation monitoring instrument used by the Office of Radiation Protection at Oak Ridge National Laboratory. This instrument must be calibrated in order to assure reliable operation. A manual calibration procedure was developed, but it was time consuming and repetitive. Therefore, an automated tester station that would allow the technicians to calibrate the instruments faster and more reliably was developed. With the automated tester station, calibration records and accountability could be generated and maintained automatically. This allows the technicians to concentrate on repairing defective units. The Automated Bicron Tester consists of an operator interface, an analog board, and a digital controller board. The panel is the user interface that allows the technician to communicate with the tester. The analog board has an analog-to-digital converter (ADC) that converts the signals from the instrument into digital data that the tester can manipulate. The digital controller board contains the circuitry to perform the test and to communicate the results to the host personal computer (PC). The tester station is connected to the unit under test through a special test harness that attaches to a header on the Bicron. The tester sends pulse trains to the Bicron and measures the resulting meter output. This is done to determine if the unit is functioning properly. The testers are connected to the host PC through an RS-485 serial line. The host PC polls all the tester stations that are connected to it and collects data from those that have completed a calibration. It logs these data and stores the record in a format ready for export to the Maintenance, Accountability, Jobs, and Inventory Control (MAJIC) database. It also prints a report. The programs for the Automated Bicron Tester and the host are written in the C language.

  4. Effects of Modes of Cockpit Automation on Pilot Performance and Workload in a Next Generation

    E-Print Network [OSTI]

    Kaber, David B.

    Effects of Modes of Cockpit Automation on Pilot Performance and Workload in a Next Generation of advanced cockpit automation for flight planning on pilot performance and workload under a futuristic arrivals to an airport using three modes of automation (MOAs), including a control-display unit (CDU

  5. NREL: Technology Deployment - Distributed Generation Interconnection...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Distributed Generation Interconnection Collaborative Become a Member DGIC members are included in quarterly informational meetings and discussions related to distributed PV...

  6. Heuristic Search with Reachability Tests for Automated Generation of Test Programs

    E-Print Network [OSTI]

    Leow, Wee Kheng

    Heuristic Search with Reachability Tests for Automated Generation of Test Programs Wee Kheng Leow specification-based soft- ware testing has focused on the automated generation of test cases. Before a software system can be tested, it must be set up according to the input requirements of the test cases. This setup

  7. DA (Distribution Automation) (Smart Grid Project) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model, clickInformationNew|CoreCpWingCushing,DA (Distribution Automation) (Smart

  8. Toward Fully Automated Multicriterial Plan Generation: A Prospective Clinical Study

    SciTech Connect (OSTI)

    Voet, Peter W.J., E-mail: p.voet@erasmusmc.nl [Department of Radiation Oncology, Erasmus Medical Center–Daniel den Hoed Cancer Center, Groene Hilledijk 301, Rotterdam 3075EA (Netherlands); Dirkx, Maarten L.P.; Breedveld, Sebastiaan; Fransen, Dennie; Levendag, Peter C.; Heijmen, Ben J.M. [Department of Radiation Oncology, Erasmus Medical Center–Daniel den Hoed Cancer Center, Groene Hilledijk 301, Rotterdam 3075EA (Netherlands)] [Department of Radiation Oncology, Erasmus Medical Center–Daniel den Hoed Cancer Center, Groene Hilledijk 301, Rotterdam 3075EA (Netherlands)

    2013-03-01T23:59:59.000Z

    Purpose: To prospectively compare plans generated with iCycle, an in-house-developed algorithm for fully automated multicriterial intensity modulated radiation therapy (IMRT) beam profile and beam orientation optimization, with plans manually generated by dosimetrists using the clinical treatment planning system. Methods and Materials: For 20 randomly selected head-and-neck cancer patients with various tumor locations (of whom 13 received sequential boost treatments), we offered the treating physician the choice between an automatically generated iCycle plan and a manually optimized plan using standard clinical procedures. Although iCycle used a fixed “wish list” with hard constraints and prioritized objectives, the dosimetrists manually selected the beam configuration and fine tuned the constraints and objectives for each IMRT plan. Dosimetrists were not informed in advance whether a competing iCycle plan was made. The 2 plans were simultaneously presented to the physician, who then selected the plan to be used for treatment. For the patient group, differences in planning target volume coverage and sparing of critical tissues were quantified. Results: In 32 of 33 plan comparisons, the physician selected the iCycle plan for treatment. This highly consistent preference for the automatically generated plans was mainly caused by the improved sparing for the large majority of critical structures. With iCycle, the normal tissue complication probabilities for the parotid and submandibular glands were reduced by 2.4% ± 4.9% (maximum, 18.5%, P=.001) and 6.5% ± 8.3% (maximum, 27%, P=.005), respectively. The reduction in the mean oral cavity dose was 2.8 ± 2.8 Gy (maximum, 8.1 Gy, P=.005). For the swallowing muscles, the esophagus and larynx, the mean dose reduction was 3.3 ± 1.1 Gy (maximum, 9.2 Gy, P<.001). For 15 of the 20 patients, target coverage was also improved. Conclusions: In 97% of cases, automatically generated plans were selected for treatment because of the superior quality. Apart from the improved plan quality, automatic plan generation is economically attractive because of the reduced workload.

  9. Integration of Demand Side Management, Distributed Generation...

    Open Energy Info (EERE)

    integration of energy efficiency, distributed generation, renewable energy resources and energy storage technologies, both locally and globally, to maximize the value of the...

  10. Distributed Generation Operational Reliability and Availability...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Reliability and Availability Database, Final Report, January 2004 Distributed Generation Operational Reliability and Availability Database, Final Report, January 2004 This final...

  11. A reliability assessment methodology for distribution systems with distributed generation

    E-Print Network [OSTI]

    Duttagupta, Suchismita Sujaya

    2006-08-16T23:59:59.000Z

    Reliability assessment is of primary importance in designing and planning distribution systems that operate in an economic manner with minimal interruption of customer loads. With the advances in renewable energy sources, Distributed Generation (DG...

  12. Worst Case Scenario for Large Distribution Networks with Distributed Generation

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Worst Case Scenario for Large Distribution Networks with Distributed Generation M. A. Mahmud) in distri- bution network has significant effects on voltage profile for both customers and distribution on variation of the voltage and the amount of DG that can be connected to the distribution networks. This paper

  13. Board Package On-Chip Automated di/dt Stressmark Generation for

    E-Print Network [OSTI]

    John, Lizy Kurian

    -- In this paper, we propose a method for automated di/dt stressmark generation to test maximum voltage droop and low current pulses that maximize voltage fluctuations including voltage droops. In order to automate and optimizing candidate instruction sequences to create a maximum voltage droop. The results show that our

  14. Microgrids: distributed on-site generation

    E-Print Network [OSTI]

    Watson, Andrew

    : · Diversity of the load profile as a function of microgrid size; · Feasibility of accurate control of bothMicrogrids: distributed on-site generation Suleiman Abu-Sharkh, Rachel Li, Tom Markvart, Neil Ross for Climate Change Research Technical Report 22 #12;1 Microgrids: distributed on-site generation Tyndall

  15. automated structure generation: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    the state-of-the-art automated grid-based layout and scheduling mechanism in terms of latency and potential pipelinability, but at the cost of some area. Mark Whitney; Nemanja...

  16. automated thrombin generation: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    the state-of-the-art automated grid-based layout and scheduling mechanism in terms of latency and potential pipelinability, but at the cost of some area. Mark Whitney; Nemanja...

  17. Automated reaction mechanism generation : improving accuracy and broadening scope

    E-Print Network [OSTI]

    Magoon, Gregory Russell

    2012-01-01T23:59:59.000Z

    Chemical kinetic modeling plays an important role in the study of reactive chemical systems. Thus, an automated means of constructing chemical kinetic models forms a useful tool in the engineering and science surrounding ...

  18. Report on Distributed Generation Penetration Study

    SciTech Connect (OSTI)

    Miller, N.; Ye, Z.

    2003-08-01T23:59:59.000Z

    This report documents part of a multiyear research program dedicated to the development of requirements to support the definition, design, and demonstration of a distributed generation-electric power system interconnection interface concept. The report focuses on the dynamic behavior of power systems when a significant portion of the total energy resource is distributed generation. It also focuses on the near-term reality that the majority of new DG relies on rotating synchronous generators for energy conversion.

  19. A DISTRIBUTED INTELLIGENT AUTOMATED DEMAND RESPONSE BUILDING MANAGEMENT SYSTEM

    SciTech Connect (OSTI)

    Auslander, David; Culler, David; Wright, Paul; Lu, Yan; Piette, Mary

    2013-12-30T23:59:59.000Z

    The goal of the 2.5 year Distributed Intelligent Automated Demand Response (DIADR) project was to reduce peak electricity load of Sutardja Dai Hall at UC Berkeley by 30% while maintaining a healthy, comfortable, and productive environment for the occupants. We sought to bring together both central and distributed control to provide “deep” demand response1 at the appliance level of the building as well as typical lighting and HVAC applications. This project brought together Siemens Corporate Research and Siemens Building Technology (the building has a Siemens Apogee Building Automation System (BAS)), Lawrence Berkeley National Laboratory (leveraging their Open Automated Demand Response (openADR), Auto-­Demand Response, and building modeling expertise), and UC Berkeley (related demand response research including distributed wireless control, and grid-­to-­building gateway development). Sutardja Dai Hall houses the Center for Information Technology Research in the Interest of Society (CITRIS), which fosters collaboration among industry and faculty and students of four UC campuses (Berkeley, Davis, Merced, and Santa Cruz). The 141,000 square foot building, occupied in 2009, includes typical office spaces and a nanofabrication laboratory. Heating is provided by a district heating system (steam from campus as a byproduct of the campus cogeneration plant); cooling is provided by one of two chillers: a more typical electric centrifugal compressor chiller designed for the cool months (Nov-­ March) and a steam absorption chiller for use in the warm months (April-­October). Lighting in the open office areas is provided by direct-­indirect luminaries with Building Management System-­based scheduling for open areas, and occupancy sensors for private office areas. For the purposes of this project, we focused on the office portion of the building. Annual energy consumption is approximately 8053 MWh; the office portion is estimated as 1924 MWh. The maximum peak load during the study period was 1175 kW. Several new tools facilitated this work, such as the Smart Energy Box, the distributed load controller or Energy Information Gateway, the web-­based DR controller (dubbed the Central Load-­Shed Coordinator or CLSC), and the Demand Response Capacity Assessment & Operation Assistance Tool (DRCAOT). In addition, an innovative data aggregator called sMAP (simple Measurement and Actuation Profile) allowed data from different sources collected in a compact form and facilitated detailed analysis of the building systems operation. A smart phone application (RAP or Rapid Audit Protocol) facilitated an inventory of the building’s plug loads. Carbon dioxide sensors located in conference rooms and classrooms allowed demand controlled ventilation. The extensive submetering and nimble access to this data provided great insight into the details of the building operation as well as quick diagnostics and analyses of tests. For example, students discovered a short-­cycling chiller, a stuck damper, and a leaking cooling coil in the first field tests. For our final field tests, we were able to see how each zone was affected by the DR strategies (e.g., the offices on the 7th floor grew very warm quickly) and fine-­tune the strategies accordingly.

  20. Nonlinear DSTATCOM controller design for distribution network with distributed generation to enhance voltage stability

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Nonlinear DSTATCOM controller design for distribution network with distributed generation Accepted 19 June 2013 Keywords: Distributed generation Distribution network DSATACOM Partial feedback connected to a distribution network with distributed generation (DG) to regulate the line voltage

  1. automated distribution system: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

  2. Distributed Generation Dispatch Optimization under Various Electricity Tariffs

    E-Print Network [OSTI]

    Firestone, Ryan; Marnay, Chris

    2007-01-01T23:59:59.000Z

    LBNL-54447. Distributed Generation Dispatch OptimizationA Business Case for On-Site Generation: The BD Biosciencesrelated work. Distributed Generation Dispatch Optimization

  3. Distributed Generation Investment by a Microgrid Under Uncertainty

    E-Print Network [OSTI]

    Siddiqui, Afzal; Marnay, Chris

    2006-01-01T23:59:59.000Z

    option on natural gas generation, which increases in valueL ABORATORY Distributed Generation Investment by a MicrogridORMMES’06 Distributed Generation Investment by a Microgrid

  4. Abatement of Air Pollution: Distributed Generators (Connecticut)

    Broader source: Energy.gov [DOE]

    For the purpose of these regulations, a distributed generator is defined as any equipment that converts primary fuel, including fossil fuel and renewable fuel, into electricity or electricity and...

  5. Distributed generation - the fuel processing example

    SciTech Connect (OSTI)

    Victor, R.A. [Praxair, Inc., Tonawanda, NY (United States); Farris, P.J.; Maston, V. [International Fuel Cells Corp., South Windsor, CT (United States)

    1996-12-31T23:59:59.000Z

    The increased costs of transportation and distribution are leading many commercial and industrial firms to consider the on-site generation for energy and other commodities used in their facilities. This trend has been accelerated by the development of compact, efficient processes for converting basic raw materials into finished services at the distributed sites. Distributed generation with the PC25{trademark} fuel cell power plant is providing a new cost effective technology to meet building electric and thermal needs. Small compact on-site separator systems are providing nitrogen and oxygen to many industrial users of these gases. The adaptation of the fuel processing section of the PC25 power plant for on-site hydrogen generation at industrial sites extends distributed generation benefits to the users of industrial hydrogen.

  6. Voltage Management of Networks with Distributed Generation

    E-Print Network [OSTI]

    O'Donnell, James

    2008-01-01T23:59:59.000Z

    At present there is much debate about the impacts and benefits of increasing the amount of generation connected to the low voltage areas of the electricity distribution network. The UK government is under political ...

  7. The Potential Benefits of Distributed Generation and the Rate...

    Broader source: Energy.gov (indexed) [DOE]

    The Potential Benefits of Distributed Generation and the Rate-Related Issues That May Impede Its Expansion The Potential Benefits of Distributed Generation and the Rate-Related...

  8. Distributed Generation Dispatch Optimization under Various Electricity Tariffs

    E-Print Network [OSTI]

    Firestone, Ryan; Marnay, Chris

    2007-01-01T23:59:59.000Z

    utility experience with RTP tariffs is described in 3. Distributed GenerationUtilities Commission, Division of Ratepayer Advocates have also provided support on related work. Distributed Generation

  9. The Value of Distributed Generation and CHP Resources in Wholesale...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    The Value of Distributed Generation and CHP Resources in Wholesale Power Markets, September 2005 The Value of Distributed Generation and CHP Resources in Wholesale Power Markets,...

  10. Hybrid Control Network Intrusion Detection Systems for Automated Power Distribution Systems

    E-Print Network [OSTI]

    Peisert, Sean

    ) for protecting automated distribution systems (ADS) against certain types of cyber attacks in a new way, distribution au- tomation, network security, intrusion detection systems. I. INTRODUCTION A. Scope and Goals their development with that of an appropriate cyber security frame- work that would prevent attackers from gaining

  11. Abstract--Implementation of Distribution Automation (DA) and Demand Side Management (DSM) intended to serve both

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Abstract--Implementation of Distribution Automation (DA) and Demand Side Management (DSM) intended with differentiate QoS in a multitasking environment. I. INTRODUCTION ODERN society demands a reliable and high by the distribution utility for the security. REMPLI (Remote Energy Management over Power Lines and Internet) system

  12. Automated Test Generation for Access Control Policies Evan Martin

    E-Print Network [OSTI]

    Xie, Tao

    North Carolina State University Raleigh, NC 27695 eemartin@ncsu.edu Tao Xie Department of Computer of responses) against expected ones. Unfortunately, manual test generation is tedious and manually generated mechanisms control which principals such as users and processes have access to which resources in a system

  13. Heuristic Search with Reachability Tests for Automated Generation of Test Programs

    E-Print Network [OSTI]

    Leow, Wee Kheng

    Heuristic Search with Reachability Tests for Automated Generation of Test Programs Wee Kheng Leow research on au- tomated specification-based testing by proposing a scheme that combines the setup process, test execution, and test val- idation into a single test program for testing the behavior of object

  14. The automated generation of Web documents that are tailored to the individual reader

    E-Print Network [OSTI]

    DiMarco, Chrysanne

    for the management and presentation of Web documents would be a very important enhance- ment of the Web's current in a system for the manage- ment and presentation of Web documents would be a very important enhancementThe automated generation of Web documents that are tailored to the individual reader Chrysanne Di

  15. Automated Environment Generation for Software Model Checking Oksana Tkachuk, Matthew B. Dwyer

    E-Print Network [OSTI]

    Pasareanu, Corina

    Automated Environment Generation for Software Model Checking Oksana Tkachuk, Matthew B. Dwyer programs or about program components, an abstract model of the environment can be essential in enabling environment behavior with sound abstractions of environment implemen­ tations to form a model

  16. Distributed Generation Dispatch Optimization under Various Electricity Tariffs

    E-Print Network [OSTI]

    Firestone, Ryan; Marnay, Chris

    2007-01-01T23:59:59.000Z

    time of use United States Postal Service v Distributed Generation Dispatch Optimization Under Various Electricity Tariffs

  17. Greenhouse Gas Abatement with Distributed Generation in California's Commercial Buildings

    E-Print Network [OSTI]

    Stadler, Michael

    2010-01-01T23:59:59.000Z

    utility electricity and natural gas purchases, amortized capital and maintenance costs for distributed generation (

  18. Automated Diagnosis and Classification of Steam Generator Tube Defects

    SciTech Connect (OSTI)

    Dr. Gabe V. Garcia

    2004-10-01T23:59:59.000Z

    A major cause of failure in nuclear steam generators is tube degradation. Tube defects are divided into seven categories, one of which is intergranular attack/stress corrosion cracking (IGA/SCC). Defects of this type usually begin on the outer surface of the tubes and propagate both inward and laterally. In many cases these defects occur at or near the tube support plates. Several different methods exist for the nondestructive evaluation of nuclear steam generator tubes for defect characterization.

  19. Avoiding Distribution System Upgrade Costs Using Distributed Generation

    SciTech Connect (OSTI)

    Schienbein, Lawrence A.; Balducci, Patrick J.; Nguyen, Tony B.; Brown, Daryl R.; DeSteese, John G.; Speer, Gregory A.

    2004-01-20T23:59:59.000Z

    PNNL, in cooperation with three utilities, developed a database and methodology to analyze and characterize the avoided costs of Distributed Generation (DG) deployment as an alternative to traditional distribution system investment. After applying a number of screening criteria to the initial set of 307 cases, eighteen were selected for detailed analysis. Alternative DG investment scenarios were developed for these cases to permit capital, operation, maintenance, and fuel costs to be identified and incorporated into the analysis. The “customer-owned” backup power generator option was also investigated. The results of the analysis of the 18 cases show that none yielded cost savings under the alternative DG scenarios. However, the DG alternative systems were configured using very restrictive assumptions concerning reliability, peak rating, engine types and acceptable fuel. In particular it was assumed that the DG alternative in each case must meet the reliability required of conventional distribution systems (99.91% reliability). The analysis was further constrained by a requirement that each substation meet the demands placed upon it by a one in three weather occurrence. To determine if, by relaxing these requirements, the DG alternative might be more viable, one project was re-examined. The 99.91% reliability factor was still assumed for normal operating conditions but redundancy required to maintain reliability was relaxed for the relatively few hours every three years where extreme weather caused load to exceed present substation capacity. This resulted in the deferment of capital investment until later years and reduced the number of engines required for the project. The cost of both the conventional and DG alternative also dropped because the centralized power generation, variable O&M, and DG fuels costs were calculated based on present load requirements in combination with long-term forecasts of load growth, as opposed to load requirements plus a buffer based on predictions of extraordinary weather conditions. Application of the relaxed set of assumptions reduced the total cost of the DG alternative by roughly 57 percent from $7.0 million to $3.0 million. The reduction, however, did not change the overall result of the analysis, as the cost of the conventional distribution system upgrade alternative remained lower at $1.7 million. This paper also explores the feasibility of using a system of backup generators to defer investment in distribution system infrastructure. Rather than expanding substation capacity at substations experiencing slow load growth rates, PNNL considered a scenario where diesel generators were installed on location at customers participating in a program designed to offer additional power security and reliability to the customer and connection to the grid. The backup generators, in turn, could be used to meet peak demand for a limited number of hours each year, thus deferring distribution system investment. Data from an existing program at one of the three participating utilities was used to quantify the costs associated with the backup generator scenario. The results of the “customer owned” backup power generator analysis showed that in all cases the nominal cost of the DG scenario is more than the nominal cost of the base-case conventional distribution system upgrade scenario. However, in two of the cases the total present value costs of the alternative backup generator scenarios were between 15 and 22% less than those for the conventional scenarios. Overall, the results of the study offer considerable encouragement that the use of DG systems can defer conventional distribution system upgrades under the right conditions and when the DG configurations are intelligently designed. Using existing customer-owned DG to defer distribution system upgrades appears to be an immediate commercially-viable opportunity.

  20. A Distributed Generation Control Architecture for Islanded AC Microgrids

    E-Print Network [OSTI]

    Dominguez-Garcia, Alejandro

    1 A Distributed Generation Control Architecture for Islanded AC Microgrids Stanton T. Cady, Student architecture for generation control in islanded microgrids, and illustrate the performance Member, IEEE Abstract In this paper, we propose a distributed architecture for generation control

  1. Physical Effects of Distributed PV Generation on California's Distribution System

    E-Print Network [OSTI]

    Cohen, Michael A

    2015-01-01T23:59:59.000Z

    Deployment of high-penetration photovoltaic (PV) power is expected to have a range of effects -- both positive and negative -- on the distribution grid. The magnitude of these effects may vary greatly depending upon feeder topology, climate, PV penetration level, and other factors. In this paper we present a simulation study of eight representative distribution feeders in three California climates at PV penetration levels up to 100\\%, supported by a unique database of distributed PV generation data that enables us to capture the impact of PV variability on feeder voltage and voltage regulating equipment. When comparing the influence of feeder location (i.e. climate) versus feeder type on outcomes, we find that location more strongly influences the incidence of reverse power flow, reductions in peak loading and the presence of voltage excursions. On the other hand, we find that feeder characteristics more strongly influence the magnitude of loss reduction and changes in voltage regulator operations. We find th...

  2. Automated Energy Distribution and Reliability System: Validation Integration - Results of Future Architecture Implementation

    SciTech Connect (OSTI)

    Buche, D. L.

    2008-06-01T23:59:59.000Z

    This report describes Northern Indiana Public Service Co. project efforts to develop an automated energy distribution and reliability system. The purpose of this project was to implement a database-driven GIS solution that would manage all of the company's gas, electric, and landbase objects. This report is second in a series of reports detailing this effort.

  3. Distributed Generation: Challenges and Opportunities, 7. edition

    SciTech Connect (OSTI)

    NONE

    2007-10-15T23:59:59.000Z

    The report is a comprehensive study of the Distributed Generation (DG) industry. The report takes a wide-ranging look at the current and future state of DG and both individually and collectively addresses the technologies of Microturbines, Reciprocating Engines, Stirling Engines, Fuel Cells, Photovoltaics, Concentrating Solar, Wind, and Microgrids. Topics covered include: the key technologies being used or planned for DG; the uses of DG from utility, energy service provider, and customer viewpoints; the economics of DG; the benefits of DG from multiple perspectives; the barriers that exist to implementing DG; the government programs supporting the DG industry; and, an analysis of DG interconnection and net metering rules.

  4. Centralized and Distributed Generated Power Systems -A Comparison Approach

    E-Print Network [OSTI]

    White Paper Power Systems Engineering Research Center Empowering Minds to Engineer the Future ElectricCentralized and Distributed Generated Power Systems - A Comparison Approach Future Grid Initiative Energy System #12;Centralized and Distributed Generated Power Systems - A Comparison Approach Prepared

  5. City of San Marcos- Distributed Generation Rebate Program (Texas)

    Broader source: Energy.gov [DOE]

    The City of San Marcos offers a Distributed Generation Rebate Program for the installation of grid-tied renewable energy systems. The Distributed Generation Rebate Program is offered on a first...

  6. Distributed multicast tree generation with dynamic group membership Frank Adelsteina

    E-Print Network [OSTI]

    Richard III, Golden G.

    Distributed multicast tree generation with dynamic group membership Frank Adelsteina , Golden G. Another distinguishing character- istic for tree generation algorithms is centralized versus distributed, efficient network utilization becomes a growing concern. Multicast transmission may use network bandwidth

  7. Distributed Generation with Heat Recovery and Storage

    SciTech Connect (OSTI)

    Siddiqui, Afzal; Marnay, Chris; Firestone, Ryan M.; Zhou, Nan

    2005-07-29T23:59:59.000Z

    Electricity generated by distributed energy resources (DER) located close to end-use loads has the potential to meet consumer requirements more efficiently than the existing centralized grid. Installation of DER allows consumers to circumvent the costs associated with transmission congestion and other non-energy costs of electricity delivery and potentially to take advantage of market opportunities to purchase energy when attractive. On-site thermal power generation is typically less efficient than central station generation, but by avoiding non-fuel costs of grid power and utilizing combined heat and power (CHP) applications, i.e., recovering heat from small-scale on-site generation to displace fuel purchases, then DER can become attractive to a strictly cost-minimizing consumer. In previous efforts, the decisions facing typical commercial consumers have been addressed using a mixed-integer linear programme, the DER Customer Adoption Model(DER-CAM). Given the site s energy loads, utility tariff structure, and information (both technical and financial) on candidate DER technologies, DER-CAM minimizes the overall energy cost for a test year by selecting the units to install and determining their hourly operating schedules. In this paper, the capabilities of DER-CAM are enhanced by the inclusion of the option to store recovered low-grade heat. By being able to keep an inventory of heat for use in subsequent periods, sites are able to lower costs even further by reducing off-peak generation and relying on storage. This and other effects of storages are demonstrated by analysis of five typical commercial buildings in San Francisco, California, and an estimate of the cost per unit capacity of heat storage is calculated.

  8. Investment and Upgrade in Distributed Generation under Uncertainty

    E-Print Network [OSTI]

    Siddiqui, Afzal

    2008-01-01T23:59:59.000Z

    utility tari?s, the electricity price may be revised only Investment and Upgrade in Distributed Generation

  9. Design-by-Analogy Using the WordTree Method and an Automated WordTree Generating Tool

    E-Print Network [OSTI]

    Oriakhi, Edgar Velazquez

    2012-07-16T23:59:59.000Z

    DESIGN-BY-ANALOGY USING THE WORDTREE METHOD AND AN AUTOMATED WORDTREE GENERATING TOOL A Thesis by EDGAR VELAZQUEZ ORIAKHI Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment... of the requirements for the degree of MASTER OF SCIENCE May 2011 Major Subject: Mechanical Engineering DESIGN-BY-ANALOGY USING THE WORDTREE METHOD AND AN AUTOMATED WORDTREE GENERATING TOOL A Thesis by EDGAR VELAZQUEZ ORIAKHI Submitted...

  10. Automatically Generating Symbolic Prefetches for Distributed Transactional Memories

    E-Print Network [OSTI]

    Boyer, Edmond

    Automatically Generating Symbolic Prefetches for Distributed Transactional Memories Alokika Dash and Brian Demsky University of California, Irvine Abstract. Developing efficient distributed applications for distributed applications. We propose a new approach to prefetching, symbolic prefetching, that can prefetch

  11. Distributed Generation with Heat Recovery and Storage

    E-Print Network [OSTI]

    Siddiqui, Afzal S.; Marnay, Chris; Firestone, Ryan M.; Zhou, Nan

    2008-01-01T23:59:59.000Z

    selection of on-site power generation with combined heat andTotal Electricity Generation Figure 13. Small MercantileWeekday Total Electricity Generation (No Storage Adoption

  12. SOFC combined cycle systems for distributed generation

    SciTech Connect (OSTI)

    Brown, R.A.

    1997-05-01T23:59:59.000Z

    The final phase of the tubular SOFC development program will focus on the development and demonstration of pressurized solid oxide fuel cell (PSOFC)/gas turbine (GT) combined cycle power systems for distributed power applications. The commercial PSOFC/GT product line will cover the power range 200 kWe to 50 MWe, and the electrical efficiency for these systems will range from 60 to 75% (net AC/LHV CH4), the highest of any known fossil fueled power generation technology. The first demonstration of a pressurized solid oxide fuel cell/gas turbine combined cycle will be a proof-of-concept 250 kWe PSOFC/MTG power system consisting of a single 200 kWe PSOFC module and a 50 kWe microturbine generator (MTG). The second demonstration of this combined cycle will be 1.3 MWe fully packaged, commercial prototype PSOFC/GT power system consisting of two 500 kWe PSOFC modules and a 300 kWe gas turbine.

  13. Distributed Generation with Heat Recovery and Storage

    SciTech Connect (OSTI)

    Siddiqui, Afzal S.; Marnay, Chris; Firestone, Ryan M.; Zhou, Nan

    2006-06-16T23:59:59.000Z

    Electricity produced by distributed energy resources (DER)located close to end-use loads has the potential to meet consumerrequirements more efficiently than the existing centralized grid.Installation of DER allows consumers to circumvent the costs associatedwith transmission congestion and other non-energy costs of electricitydelivery and potentially to take advantage of market opportunities topurchase energy when attractive. On-site, single-cycle thermal powergeneration is typically less efficient than central station generation,but by avoiding non-fuel costs of grid power and by utilizing combinedheat and power (CHP) applications, i.e., recovering heat from small-scaleon-site thermal generation to displace fuel purchases, DER can becomeattractive to a strictly cost-minimizing consumer. In previous efforts,the decisions facing typical commercial consumers have been addressedusing a mixed-integer linear program, the DER Customer Adoption Model(DER-CAM). Given the site s energy loads, utility tariff structure, andinformation (both technical and financial) on candidate DER technologies,DER-CAM minimizes the overall energy cost for a test year by selectingthe units to install and determining their hourly operating schedules. Inthis paper, the capabilities of DER-CAM are enhanced by the inclusion ofthe option to store recovered low-grade heat. By being able to keep aninventory of heat for use in subsequent periods, sites are able to lowercosts even further by reducing lucrative peak-shaving generation whilerelying on storage to meet heat loads. This and other effects of storageare demonstrated by analysis of five typical commercial buildings in SanFrancisco, California, USA, and an estimate of the cost per unit capacityof heat storage is calculated.

  14. Extending and automating a Systems-Theoretic hazard analysis for requirements generation and analysis.

    SciTech Connect (OSTI)

    Thomas, John (Massachusetts Institute of Technology)

    2012-05-01T23:59:59.000Z

    Systems Theoretic Process Analysis (STPA) is a powerful new hazard analysis method designed to go beyond traditional safety techniques - such as Fault Tree Analysis (FTA) - that overlook important causes of accidents like flawed requirements, dysfunctional component interactions, and software errors. While proving to be very effective on real systems, no formal structure has been defined for STPA and its application has been ad-hoc with no rigorous procedures or model-based design tools. This report defines a formal mathematical structure underlying STPA and describes a procedure for systematically performing an STPA analysis based on that structure. A method for using the results of the hazard analysis to generate formal safety-critical, model-based system and software requirements is also presented. Techniques to automate both the analysis and the requirements generation are introduced, as well as a method to detect conflicts between the safety and other functional model-based requirements during early development of the system.

  15. June 2014 Most Viewed Documents for Power Generation And Distribution...

    Office of Scientific and Technical Information (OSTI)

    Documents for Power Generation And Distribution Science Subject Feed Seventh Edition Fuel Cell Handbook NETL (2004) 118 > Electric power high-voltage transmission lines:...

  16. A Valuation-Based Framework for Considering Distributed Generation...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    tools to inform further discussions. Keywords-tariff design, ratemaking, distributed generation, photovoltaic, solar valuation, value of solar, cost-benefit analysis I....

  17. Distributed Generation Investment by a Microgrid under Uncertainty

    E-Print Network [OSTI]

    Siddiqui, Afzal

    2008-01-01T23:59:59.000Z

    L, editor. 11 th Annual Real Options Conference, Berkeley,from its utility. Using the real options approach, we find aDistributed Generation; Real Options; Optimal Investment;

  18. Distributed Generation Investment by a Microgrid Under Uncertainty

    E-Print Network [OSTI]

    Siddiqui, Afzal; Marnay, Chris

    2006-01-01T23:59:59.000Z

    utility. Using the real options approach, we find naturalDistributed Generation; Real Options; Optimal Investment. 1.based microgrid via the real options approach to determine

  19. Poland - Economic and Financial Benefits of Distributed Generation...

    Open Energy Info (EERE)

    of Distributed Generation Small-Scale, Gas-Fired CHP AgencyCompany Organization Argonne National Laboratory Sector Energy Topics Background analysis Website http:...

  20. Distributed Generation with Heat Recovery and Storage

    E-Print Network [OSTI]

    Siddiqui, Afzal S.; Marnay, Chris; Firestone, Ryan M.; Zhou, Nan

    2008-01-01T23:59:59.000Z

    Only Load Electricity Generation By Fuel in the U.S.electricity generation from most sources, except oil, is growing to meet the growing demand and that fossil fuels

  1. SMALL TURBOGENERATOR TECHNOLOGY FOR DISTRIBUTED GENERATION

    SciTech Connect (OSTI)

    Sy Ali; Bob Moritz

    2001-09-01T23:59:59.000Z

    This report is produced in under Contract DE-FC26-00NT40914, awarded in accordance with U.S. Department of Energy solicitation DE-PS26-00FT40759, ''Development of Technologies and Capabilities for Fossil Energy-Wide Coal, Natural Gas and Oil R&D Programs'', area of interest 7, ''Advanced Turbines and Engines.'' As a result of ten years of collaborative fuel cell systems studies with U.S. fuel cell manufacturers, initiated to evaluate the gas turbine opportunities likely to result from this technology, Rolls-Royce in Indianapolis has established a clear need for the creation of a turbogenerator to a specification that cannot be met by available units. Many of the required qualities are approached, but not fully met, by microturbines, which tend to be too small and low in pressure ratio. Market evaluation suggests a 1 MW fuel cell hybrid, incorporating a turbogenerator of about 250 kW, is a good market entry product (large enough to spread the costs of a relatively complex plant, but small enough to be acceptable to early adopters). The fuel cell stack occupies the position of a combustor in the turbogenerator, but delivers relatively low turbine entry temperature (1600 F [870 C]). If fitted with a conventional combustor and run stand-alone at full uncooled turbine temperature (1800 F [980 C]), the turbogenerator will develop more power. The power can be further enhanced if the turbogenerator is designed to have flow margin in its fuel cell role (by running faster). This margin can be realized by running at full speed and it is found that power can be increased to the 0.7 to 1.0 MW range, depending on initial fuel cell stack flow demand. The fuel cell hybrid applications require increased pressure ratio (at least 6 rather than the 3-4 of microturbines) and very long life for a small machine. The outcome is a turbogenerator that is very attractive for stand-alone operation and has been the subject of unsolicited enthusiasm from potential users who see an application in grid support. The machine is consistent with 21st century power generation objectives. It will be more efficient than a microturbine and also more cost effective because it does not require an expensive recuperator. It will produce ultra-low emissions because it has a low combustor delivery temperature. It will also avoid producing hazardous waste because it requires no lube system. These qualities are obtained by combining, and in some instances extending, the best of available technologies rather than breaking wholly new ground. Limited ''barrier technology'' rig tests of bearing systems and alternator configuration are proposed to support the extension of technology. Low combustion temperature also has merit in handling alternative fuels with minimum emissions and minimum materials degradation. Program continuation is proposed that will simultaneously provide technology support to a SECA fuel cell hybrid system and a distributed generation turbogenerator. This technology program will be led by a Rolls-Royce team based in Indianapolis with access to extensive small turbogenerator experience gathered in DOE (and other) programs by Allison Mobile Power Systems. It is intended that subsequent production will be in the U.S., but the products may have substantial export potential.

  2. Integration of Demand Side Management, Distributed Generation...

    Open Energy Info (EERE)

    generation, smart grid and energy storage. Annex 9 is a list of pilot programs and case studies, with links to those resources. References Retrieved from "http:...

  3. Investment and Upgrade in Distributed Generation under Uncertainty

    E-Print Network [OSTI]

    Guillas, Serge

    decision as the opportunity cost of exercising the investment option increases as well. In this paper, weInvestment and Upgrade in Distributed Generation under Uncertainty Afzal Siddiqui Karl Maribu 13 for microgrids to use small-scale distributed generation (DG) and combined heat and power (CHP) applications via

  4. Distributed Generation in Buildings (released in AEO2005)

    Reports and Publications (EIA)

    2008-01-01T23:59:59.000Z

    Currently, distributed generation provides a very small share of residential and commercial electricity requirements in the United States. The Annual Energy Outlook 2005 reference case projects a significant increase in electricity generation in the buildings sector, but distributed generation is expected to remain a small contributor to the sectors energy needs. Although the advent of higher energy prices or more rapid improvement in technology could increase the use of distributed generation relative to the reference case projection, the vast majority of electricity used in buildings is projected to continue to be purchased from the grid.

  5. Automated third generation squark production to next-to-leading order

    E-Print Network [OSTI]

    Dorival Goncalves; David Lopez-Val; Kentarou Mawatari; Tilman Plehn

    2014-07-16T23:59:59.000Z

    If light--flavor squarks and gluinos are indeed heavy and chargino pair production is plagued with overwhelming backgrounds, pair production and associated production of stops and charginos will become the key signatures in the upcoming LHC runs. We present fully automated next-to-leading order predictions for heavy flavor squark production at the LHC, including stop-chargino associated production, based on MadGolem. We compute the total and differential NLO rates for a variety of MSSM scenarios with a light third generation. We focus on theoretical uncertainties on differential rates, including a comparison to multi-jet merging and the impact of bottom parton densities for stop-chargino associated production. We find that for the associated production channel the rates can reach tens of femtobarns, but the scale dependence does not provide a conservative estimate of the theoretical uncertainties.

  6. Distributed Medium Access Control for Next Generation CDMA Wireless Networks

    E-Print Network [OSTI]

    Zhuang, Weihua

    Distributed Medium Access Control for Next Generation CDMA Wireless Networks Hai Jiang, Princeton wireless networks are expected to have a simple infrastructure with distributed control. In this article, we consider a generic distributed network model for future wireless multi- media communications

  7. A reliability assessment methodology for distribution systems with distributed generation 

    E-Print Network [OSTI]

    Duttagupta, Suchismita Sujaya

    2006-08-16T23:59:59.000Z

    Reliability assessment is of primary importance in designing and planning distribution systems that operate in an economic manner with minimal interruption of customer loads. With the advances in renewable energy sources, ...

  8. Operation of Distributed Generation Under Stochastic Prices

    SciTech Connect (OSTI)

    Siddiqui, Afzal S.; Marnay, Chris

    2005-11-30T23:59:59.000Z

    We model the operating decisions of a commercial enterprisethatneeds to satisfy its periodic electricity demand with either on-sitedistributed generation (DG) or purchases from the wholesale market. Whilethe former option involves electricity generation at relatively high andpossibly stochastic costs from a set of capacity-constrained DGtechnologies, the latter implies unlimited open-market transactions atstochastic prices. A stochastic dynamic programme (SDP) is used to solvethe resulting optimisation problem. By solving the SDP with and withoutthe availability of DG units, the implied option values of the DG unitsare obtained.

  9. Options for Control of Reactive Power by Distributed Photovoltaic Generators

    E-Print Network [OSTI]

    Sulc, Petr; Backhaus, Scott; Chertkov, Michael

    2010-01-01T23:59:59.000Z

    High penetration levels of distributed photovoltaic(PV) generation on an electrical distribution circuit present several challenges and opportunities for distribution utilities. Rapidly varying irradiance conditions may cause voltage sags and swells that cannot be compensated by slowly responding utility equipment resulting in a degradation of power quality. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g. by minimizing thermal losses. We discuss and compare via simulation various design options for control systems to manage the reactive power generated by these inverters. An important design de...

  10. Distributed Generation Dispatch Optimization under Various Electricity Tariffs

    E-Print Network [OSTI]

    Firestone, Ryan; Marnay, Chris

    2007-01-01T23:59:59.000Z

    purchase abs. cooling offset electric supply (kW) hourTariffs electric supply (kW) abs. cooling offset purchasecooling offset Distributed Generation Dispatch Optimization Under Various Electricity Tariffs electric supply (

  11. Investment and Upgrade in Distributed Generation under Uncertainty

    E-Print Network [OSTI]

    Siddiqui, Afzal

    2008-01-01T23:59:59.000Z

    ment of uncertainty via real options increases the value of2007) and the 2007 Real Options Conference in Berkeley, CA,distributed generation, real options JEL Codes: D81, Q40

  12. Advanced Distributed Generation LLC | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualProperty Edit withTianlinPapersWindeySanta Clara,Addington,Admire,CA 94105Advanced Distributed

  13. Distributed Generation Systems Inc | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualPropertyd8c-a9ae-f8521cbb8489 No revision| Open Energy Information At1986)Distributed

  14. Local Control of Reactive Power by Distributed Photovoltaic Generators

    E-Print Network [OSTI]

    Turitsyn, Konstantin S; Backhaus, Scott; Chertkov, Misha

    2010-01-01T23:59:59.000Z

    High penetration levels of distributed photovoltaic (PV) generation on an electrical distribution circuit may severely degrade power quality due to voltage sags and swells caused by rapidly varying PV generation during cloud transients coupled with the slow response of existing utility compensation and regulation equipment. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g. by minimizing thermal losses. We suggest a local control scheme that dispatches reactive power from each PV inverter based on local instantaneous measurements of the real and reactive components of the consumed power and the re...

  15. Local control of reactive power by distributed photovoltaic generators

    SciTech Connect (OSTI)

    Chertkov, Michael [Los Alamos National Laboratory; Turitsyn, Konstantin [Los Alamos National Laboratory; Sulc, Petr [Los Alamos National Laboratory; Backhaus, Scott [Los Alamos National Laboratory

    2010-01-01T23:59:59.000Z

    High penetration levels of distributed photovoltaic (PV) generation on an electrical distribution circuit may severely degrade power quality due to voltage sags and swells caused by rapidly varying PV generation during cloud transients coupled with the slow response of existing utility compensation and regulation equipment. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g. by minimizing thermal losses. We suggest a local control scheme that dispatches reactive power from each PV inverter based on local instantaneous measurements of the real and reactive components of the consumed power and the real power generated by the PVs. Using one adjustable parameter per circuit, we balance the requirements on power quality and desire to minimize thermal losses. Numerical analysis of two exemplary systems, with comparable total PV generation albeit a different spatial distribution, show how to adjust the optimization parameter depending on the goal. Overall, this local scheme shows excellent performance; it's capable of guaranteeing acceptable power quality and achieving significant saving in thermal losses in various situations even when the renewable generation in excess of the circuit own load, i.e. feeding power back to the higher-level system.

  16. A mathematical basis for automated structured grid generation with close coupling to the flow solver

    SciTech Connect (OSTI)

    Barnette, D.W.

    1998-02-01T23:59:59.000Z

    The first two truncation error terms resulting from finite differencing the convection terms in the two-dimensional Navier-Stokes equations are examined for the purpose of constructing two-dimensional grid generation schemes. These schemes are constructed such that the resulting grid distributions drive the error terms to zero. Two sets of equations result, one for each error term, that show promise in generating grids that provide more accurate flow solutions and possibly faster convergence. One set results in an algebraic scheme that drives the first truncation term to zero, and the other a hyperbolic scheme that drives the second term to zero. Also discussed is the possibility of using the schemes in sequentially constructing a grid in an iterative algorithm involving the flow solver. In essence, the process is envisioned to generate not only a flow field solution but the grid as well, rendering the approach a hands-off method for grid generation

  17. Generating generalized distributions from dynamical simulation

    E-Print Network [OSTI]

    Barth, Eric J.; Laird, Brian Bostian; Leimkuhler, Benedict J.

    2003-03-18T23:59:59.000Z

    virtual momentum related to the actual momentum of the system by p˜5sp.3 The equations of motion generated by the Nose´ Hamiltonian @Eq. ~1!# are dq dt 5M 21p˜/s2, ~2! dp˜ dt 52„V~q!, ~3! ds dt 5 p Q , ~4! dp dt 5 p˜TM21p˜ s3 2gkBT/s . ~5! The Nose´ method... regulates the temperature of the sys- tem through a dynamical time transformation given by dt/dt5s , where t is the Nose´ ~virtual! time and t is real time. The remarkable property of Nose´ dynamics is that mi- crocanonical sampling of the extended phase...

  18. Insertion of Distributed Generation into Rural Feeders , R. MORENO+

    E-Print Network [OSTI]

    Catholic University of Chile (Universidad Católica de Chile)

    -generating technologies with new technologies that pollute less. Therefore, the use of renewable energies in the worldwide of renewable energy distributed generators (DG) to radial feeders is assessed. Often, the long distance between, however, are not usually designed to receive energy at the consumer end. This problem intensifies

  19. Introduction to Network Analysis 21 Generating Functions and Degree Distributions

    E-Print Network [OSTI]

    Safro, Ilya

    Introduction to Network Analysis 21 Generating Functions and Degree Distributions we add zero term because of infinity #12;Introduction to Network Analysis 22 Number of second neighbors of a vertex Probability of having k second neighbors given m first neighbors degree distribution Prob excess degrees of m

  20. Low-cost distributed solar-thermal-electric power generation

    E-Print Network [OSTI]

    Sanders, Seth

    Low-cost distributed solar-thermal-electric power generation A. Der Minassians, K. H. Aschenbach discuss the technical and economic feasibility of a low-cost distributed solar-thermal-electric power technologies should be judged by output power per dollar rather than by efficiency or other technical merits

  1. Voltage Control of Distribution Networks with Distributed Generation using Reactive Power

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Voltage Control of Distribution Networks with Distributed Generation using Reactive Power to control voltage of distribution networks with DG using reactive power compensation approach. In this paper profile within the specified limits, it is essential to regulate the reactive power of the compensators

  2. Efficiency and Air Quality Implications of Distributed Generation and Combined Heat

    E-Print Network [OSTI]

    Efficiency and Air Quality Implications of Distributed Generation and Combined Heat and Power potentially increase exposure to air pollutants. When distributed generation is efficiently deployed to determine accurately the efficiencies and emissions of various applications of distributed generation

  3. Test Automation Test Automation

    E-Print Network [OSTI]

    Mousavi, Mohammad

    Test Automation Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2013 Mousavi: Test Automation #12;Test Automation Outline Test Automation Mousavi: Test Automation #12;Test Automation Why? Challenges of Manual Testing Test-case design: Choosing inputs

  4. Options for Control of Reactive Power by Distributed Photovoltaic Generators

    E-Print Network [OSTI]

    Petr Sulc; Konstantin Turitsyn; Scott Backhaus; Michael Chertkov

    2010-08-04T23:59:59.000Z

    High penetration levels of distributed photovoltaic(PV) generation on an electrical distribution circuit present several challenges and opportunities for distribution utilities. Rapidly varying irradiance conditions may cause voltage sags and swells that cannot be compensated by slowly responding utility equipment resulting in a degradation of power quality. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g. by minimizing thermal losses. We discuss and compare via simulation various design options for control systems to manage the reactive power generated by these inverters. An important design decision that weighs on the speed and quality of communication required is whether the control should be centralized or distributed (i.e. local). In general, we find that local control schemes are capable for maintaining voltage within acceptable bounds. We consider the benefits of choosing different local variables on which to control and how the control system can be continuously tuned between robust voltage control, suitable for daytime operation when circuit conditions can change rapidly, and loss minimization better suited for nighttime operation.

  5. Cascade Failures from Distributed Generation in Power Grids

    E-Print Network [OSTI]

    Scala, Antonio; Scoglio, Caterina

    2012-01-01T23:59:59.000Z

    Power grids are nowadays experiencing a transformation due to the introduction of Distributed Generation based on Renewable Sources. At difference with classical Distributed Generation, where local power sources mitigate anomalous user consumption peaks, Renewable Sources introduce in the grid intrinsically erratic power inputs. By introducing a simple schematic (but realistic) model for power grids with stochastic distributed generation, we study the effects of erratic sources on the robustness of several IEEE power grid test networks with up to 2000 buses. We find that increasing the penetration of erratic sources causes the grid to fail with a sharp transition. We compare such results with the case of failures caused by the natural increasing power demand.

  6. A planning scheme for penetrating embedded generation in power distribution grids

    E-Print Network [OSTI]

    Wang, Jiankang, Ph. D. Massachusetts Institute of Technology

    2013-01-01T23:59:59.000Z

    Penetrating Embedded Generation, or Distributed Generation (DG), in power distribution grids presents great benefits and substantial positive social impacts to utilities, system operators and electricity consumers. Existing ...

  7. Ris Energy Report 4 Distributed generation 1 What is distributed generation?

    E-Print Network [OSTI]

    generation (DG) refers to an emerging evolu- tion of the electric power generation systems, in which all of the Euro- pean Union (CEU) as an essential part of the develop- ment of the European power system the use of modelling in these contexts, including: · strategic planning and policymaking · detailed system

  8. Generate Uniform Transverse Distributed Electron Beam along a Beam Line

    E-Print Network [OSTI]

    Jiao, Y

    2015-01-01T23:59:59.000Z

    It has been reported that transverse distribution shaping can help to further enhance the energy extraction efficiency in a terawatt, tapered X-ray free-electron laser. Thus, methods of creating and keeping almost uniform transverse distributed (UTD) beam within undulators are required. This study shows that a UTD electron beam can be generated within evenly distributed drift sections where undulators can be placed, by means of octupoles and particular optics. A concrete design is presented, and numerical simulations are done to verify the proposed method.

  9. Introduction to Network Analysis 15 Generating Functions and Degree Distributions

    E-Print Network [OSTI]

    Duchowski, Andrew T.

    Introduction to Network Analysis 15 Generating Functions and Degree Distributions #12;Introduction to Network Analysis 16 Polylogarithm drawn values add to a specific sum #12;Introduction to Network Analysis-loops, multi-edges #12;Introduction to Network Analysis 18 Configuration Model Conclusion: expected number

  10. Parton distributions and event generators Stefano Carrazza, Stefano Forte

    E-Print Network [OSTI]

    Heller, Barbara

    Parton distributions and event generators Stefano Carrazza, Stefano Forte Dipartimento di Fisica ingredient in achieving all of these goals is the integration of parton distri- butions within Monte Carlo, and data collected in an experimental fiducial region. Whereas next-to-leading (NLO) order Monte Carlo

  11. Energy Storage and Distributed Energy Generation Project, Final Project Report

    SciTech Connect (OSTI)

    Schwank, Johannes; Mader, Jerry; Chen, Xiaoyin; Mi, Chris; Linic, Suljo; Sastry, Ann Marie; Stefanopoulou, Anna; Thompson, Levi; Varde, Keshav

    2008-03-31T23:59:59.000Z

    This report serves as a Final Report under the “Energy Storage and Distribution Energy Generation Project” carried out by the Transportation Energy Center (TEC) at the University of Michigan (UM). An interdisciplinary research team has been working on fundamental and applied research on: -distributed power generation and microgrids, -power electronics, and -advanced energy storage. The long-term objective of the project was to provide a framework for identifying fundamental research solutions to technology challenges of transmission and distribution, with special emphasis on distributed power generation, energy storage, control methodologies, and power electronics for microgrids, and to develop enabling technologies for novel energy storage and harvesting concepts that can be simulated, tested, and scaled up to provide relief for both underserved and overstressed portions of the Nation’s grid. TEC’s research is closely associated with Sections 5.0 and 6.0 of the DOE "Five-year Program Plan for FY2008 to FY2012 for Electric Transmission and Distribution Programs, August 2006.”

  12. Design of a Norm-Bounded LQG Controller for Power Distribution Networks with Distributed Generation

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    . Therefore, control of modern electric power systems becomes more and more challenging as the present trends control is essential. Moreover, induction motor loads account for a large portion of domestic loadsDesign of a Norm-Bounded LQG Controller for Power Distribution Networks with Distributed Generation

  13. RANDOM VARIATE GENERATION FOR THE DIGAMMA AND TRIGAMMA DISTRIBUTIONS Luc Devroye

    E-Print Network [OSTI]

    Devroye, Luc

    RANDOM VARIATE GENERATION FOR THE DIGAMMA AND TRIGAMMA DISTRIBUTIONS Luc Devroye School of Computer these distributions and selected generalized hypergeometric distributions. The generators can also be used for the discrete stable distribution, the Yule distribution, Mizutani's distribution and the Waring distribution

  14. Modeling and Verification of Distributed Generation and Voltage Regulation Equipment for Unbalanced Distribution Power Systems; Annual Subcontract Report, June 2007

    SciTech Connect (OSTI)

    Davis, M. W.; Broadwater, R.; Hambrick, J.

    2007-07-01T23:59:59.000Z

    This report summarizes the development of models for distributed generation and distribution circuit voltage regulation equipment for unbalanced power systems and their verification through actual field measurements.

  15. Laboratories for the 21st Century Best Practices: Onsite Distributed Generation Systems For Laboratories

    Broader source: Energy.gov [DOE]

    Guide describes general information on implementing onsite distributed generation systems in laboratory environments.

  16. Utility/Industry Partnerships Involving Distributed Generation Technologies in Evolving Electricity Markets

    E-Print Network [OSTI]

    Rastler, D. M.

    Wires Manage Wires defer capital Optimize Energy Services Not Utility Business Not Utility Business New Business Opportunities DISTRIBUTED GENERATION Distributed generation includes small gas turbines, micro-turbines, fuel cells, storage...UTILITYIINDUSTRY PARTNERSHIPS INVOLVING DISTRIBUTED GENERATION TECHNOLOGIES IN EVOLVING ELECTRICITY MARKETS Daniel M. Rastler Manager, Fuel Cells and Distributed Generation Electric Power Research Institute Palo Alto, California ABSTRACT...

  17. Distributed Generation Investment by a Microgrid UnderUncertainty

    SciTech Connect (OSTI)

    Siddiqui, Afzal; Marnay, Chris

    2006-06-16T23:59:59.000Z

    This paper examines a California-based microgrid s decision to invest in a distributed generation (DG) unit that operates on natural gas. While the long-term natural gas generation cost is stochastic, we initially assume that the microgrid may purchase electricity at a fixed retail rate from its utility. Using the real options approach, we find natural gas generating cost thresholds that trigger DG investment. Furthermore, the consideration of operational flexibility by the microgrid accelerates DG investment, while the option to disconnect entirely from the utility is not attractive. By allowing the electricity price to be stochastic, we next determine an investment threshold boundary and find that high electricity price volatility relative to that of natural gas generating cost delays investment while simultaneously increasing the value of the investment. We conclude by using this result to find the implicit option value of the DG unit.

  18. Distributed Generation Investment by a Microgrid under Uncertainty

    SciTech Connect (OSTI)

    Marnay, Chris; Siddiqui, Afzal; Marnay, Chris

    2008-08-11T23:59:59.000Z

    This paper examines a California-based microgrid?s decision to invest in a distributed generation (DG) unit fuelled by natural gas. While the long-term natural gas generation cost is stochastic, we initially assume that the microgrid may purchase electricity at a fixed retail rate from its utility. Using the real options approach, we find a natural gas generation cost threshold that triggers DG investment. Furthermore, the consideration of operational flexibility by the microgrid increases DG investment, while the option to disconnect from the utility is not attractive. By allowing the electricity price to be stochastic, we next determine an investment threshold boundary and find that high electricity price volatility relative to that of natural gas generation cost delays investment while simultaneously increasing the value of the investment. We conclude by using this result to find the implicit option value of the DG unit when two sources of uncertainty exist.

  19. ANALYSIS OF DISTRIBUTION FEEDER LOSSES DUE TO ADDITION OF DISTRIBUTED PHOTOVOLTAIC GENERATORS

    SciTech Connect (OSTI)

    Tuffner, Francis K.; Singh, Ruchi

    2011-08-09T23:59:59.000Z

    Distributed generators (DG) are small scale power supplying sources owned by customers or utilities and scattered throughout the power system distribution network. Distributed generation can be both renewable and non-renewable. Addition of distributed generation is primarily to increase feeder capacity and to provide peak load reduction. However, this addition comes with several impacts on the distribution feeder. Several studies have shown that addition of DG leads to reduction of feeder loss. However, most of these studies have considered lumped load and distributed load models to analyze the effects on system losses, where the dynamic variation of load due to seasonal changes is ignored. It is very important for utilities to minimize the losses under all scenarios to decrease revenue losses, promote efficient asset utilization, and therefore, increase feeder capacity. This paper will investigate an IEEE 13-node feeder populated with photovoltaic generators on detailed residential houses with water heater, Heating Ventilation and Air conditioning (HVAC) units, lights, and other plug and convenience loads. An analysis of losses for different power system components, such as transformers, underground and overhead lines, and triplex lines, will be performed. The analysis will utilize different seasons and different solar penetration levels (15%, 30%).

  20. Reliability Improvement Programs in Steam Distribution and Power Generation Systems

    E-Print Network [OSTI]

    Petto, S.

    RELIABILITY IIIPROVEfWlT PROGRAMS IN STEAM DISTRIBUTION AND POVER GENERATION SYSTEItS Steve Petto Tech/Serv Corporation Blue Bell, PA Abstract This paper will present alternatives to costly corrective maintenance of the steam trap... In the reliability and efficiency of the system. Recent studies have shownt hat more than 40% of all In stalled steam traps and 20% of certain types of valves need some form of corrective action. The majority of all high backpressure problems In condensate return...

  1. A Bio-Based Fuel Cell for Distributed Energy Generation

    SciTech Connect (OSTI)

    Anthony Terrinoni; Sean Gifford

    2008-06-30T23:59:59.000Z

    The technology we propose consists primarily of an improved design for increasing the energy density of a certain class of bio-fuel cell (BFC). The BFCs we consider are those which harvest electrons produced by microorganisms during their metabolism of organic substrates (e.g. glucose, acetate). We estimate that our technology will significantly enhance power production (per unit volume) of these BFCs, to the point where they could be employed as stand-alone systems for distributed energy generation.

  2. Fuel cycle comparison of distributed power generation technologies.

    SciTech Connect (OSTI)

    Elgowainy, A.; Wang, M. Q.; Energy Systems

    2008-12-08T23:59:59.000Z

    The fuel-cycle energy use and greenhouse gas (GHG) emissions associated with the application of fuel cells to distributed power generation were evaluated and compared with the combustion technologies of microturbines and internal combustion engines, as well as the various technologies associated with grid-electricity generation in the United States and California. The results were primarily impacted by the net electrical efficiency of the power generation technologies and the type of employed fuels. The energy use and GHG emissions associated with the electric power generation represented the majority of the total energy use of the fuel cycle and emissions for all generation pathways. Fuel cell technologies exhibited lower GHG emissions than those associated with the U.S. grid electricity and other combustion technologies. The higher-efficiency fuel cells, such as the solid oxide fuel cell (SOFC) and molten carbonate fuel cell (MCFC), exhibited lower energy requirements than those for combustion generators. The dependence of all natural-gas-based technologies on petroleum oil was lower than that of internal combustion engines using petroleum fuels. Most fuel cell technologies approaching or exceeding the DOE target efficiency of 40% offered significant reduction in energy use and GHG emissions.

  3. Optimal Solar PV Arrays Integration for Distributed Generation

    SciTech Connect (OSTI)

    Omitaomu, Olufemi A [ORNL; Li, Xueping [University of Tennessee, Knoxville (UTK)

    2012-01-01T23:59:59.000Z

    Solar photovoltaic (PV) systems hold great potential for distributed energy generation by installing PV panels on rooftops of residential and commercial buildings. Yet challenges arise along with the variability and non-dispatchability of the PV systems that affect the stability of the grid and the economics of the PV system. This paper investigates the integration of PV arrays for distributed generation applications by identifying a combination of buildings that will maximize solar energy output and minimize system variability. Particularly, we propose mean-variance optimization models to choose suitable rooftops for PV integration based on Markowitz mean-variance portfolio selection model. We further introduce quantity and cardinality constraints to result in a mixed integer quadratic programming problem. Case studies based on real data are presented. An efficient frontier is obtained for sample data that allows decision makers to choose a desired solar energy generation level with a comfortable variability tolerance level. Sensitivity analysis is conducted to show the tradeoffs between solar PV energy generation potential and variability.

  4. Assessment of Distributed Generation Potential in JapaneseBuildings

    SciTech Connect (OSTI)

    Zhou, Nan; Marnay, Chris; Firestone, Ryan; Gao, Weijun; Nishida,Masaru

    2005-05-25T23:59:59.000Z

    To meet growing energy demands, energy efficiency, renewable energy, and on-site generation coupled with effective utilization of exhaust heat will all be required. Additional benefit can be achieved by integrating these distributed technologies into distributed energy resource (DER) systems (or microgrids). This research investigates a method of choosing economically optimal DER, expanding on prior studies at the Berkeley Lab using the DER design optimization program, the Distributed Energy Resources Customer Adoption Model (DER-CAM). DER-CAM finds the optimal combination of installed equipment from available DER technologies, given prevailing utility tariffs, site electrical and thermal loads, and a menu of available equipment. It provides a global optimization, albeit idealized, that shows how the site energy loads can be served at minimum cost by selection and operation of on-site generation, heat recovery, and cooling. Five prototype Japanese commercial buildings are examined and DER-CAM applied to select the economically optimal DER system for each. The five building types are office, hospital, hotel, retail, and sports facility. Based on the optimization results, energy and emission reductions are evaluated. Furthermore, a Japan-U.S. comparison study of policy, technology, and utility tariffs relevant to DER installation is presented. Significant decreases in fuel consumption, carbon emissions, and energy costs were seen in the DER-CAM results. Savings were most noticeable in the sports facility (a very favourable CHP site), followed by the hospital, hotel, and office building.

  5. The Value of Distributed Generation under Different TariffStructures

    SciTech Connect (OSTI)

    Firestone, Ryan; Magnus Maribu, Karl; Marnay, Chris

    2006-05-31T23:59:59.000Z

    Distributed generation (DG) may play a key role in a modern energy system because it can improve energy efficiency. Reductions in the energy bill, and therefore DG attractiveness, depend on the electricity tariff structure; a system created before widespread adoption of distributed generation. Tariffs have been designed to recover costs equitably amongst customers with similar consumption patterns. Recently, electric utilities began to question the equity of this electricity pricing structure for standby service. In particular, the utilities do not feel that DG customers are paying their fair share of transmission and distribution costs - traditionally recovered through a volumetric($/kWh) mechanism - under existing tariff structures. In response, new tariff structures with higher fixed costs for DG have been implemented in New York and in California. This work analyzes the effects of different electricity tariff structures on DG adoption. First, the effects of the new standby tariffs in New York are analyzed in different regions. Next generalized tariffs are constructed, and the sensitivity to varying levels of the volumetric and the demand ($/kW, i.e. maximum rate) charge component are analyzed on New York's standard and standby tariff as well as California's standby tariff. As expected, DG profitability is reduced with standby tariffs, but often marginally. The new standby structures tend to promote smaller base load systems. The amount of time-of-day variability of volumetric pricing seems to have little effect on DG economics.

  6. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect (OSTI)

    Faress Rahman; Nguyen Minh

    2004-01-04T23:59:59.000Z

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC (HPGS) during the July 2003 to December 2003 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a micro-turbine. In addition, an activity included in this program focuses on the development of an integrated coal gasification fuel cell system concept based on planar SOFC technology. Also, another activity included in this program focuses on the development of SOFC scale up strategies.

  7. 1 Control Challenges of Fuel Cell-Driven Distributed Generation

    E-Print Network [OSTI]

    Valery Knyazkin; Lennart Söder; Claudio Canizares

    Abstract — This paper discusses the load following capability of fuel cell-driven power plants. A linear model of a Solid Oxide Fuel Cell power plant is obtained and utilized for the design of robust controllers which enhance tracking response of the plant and reject disturbances originating from the distribution grid. Two robust controllers are synthesized applying the H? mixed-sensitivity optimization and their performance is validated by means of nonlinear time-domain simulations. The obtained results indicate that the disturbances can be successfully attenuated; however, the tracking response cannot be significantly improved without a modification of the design of the fuel cell power plant. The paper is concluded by a brief discussion on the physical limitations on the fuel cell output power ramp and possible solutions are outlined. Index Terms — Distributed generation, Solid Oxide Fuel Cells, robust control, H ? controller design, disturbance rejection.

  8. Emissions Benefits of Distributed Generation in the Texas Market

    SciTech Connect (OSTI)

    Hadley, SW

    2005-06-16T23:59:59.000Z

    One potential benefit of distributed generation (DG) is a net reduction in air emissions. While DG will produce emissions, most notably carbon dioxide and nitrogen oxides, the power it displaces might have produced more. This study used a system dispatch model developed at Oak Ridge National Laboratory to simulate the 2012 Texas power market with and without DG. This study compares the reduction in system emissions to the emissions from the DG to determine the net savings. Some of the major findings are that 85% of the electricity displaced by DG during peak hours will be simple cycle natural gas, either steam or combustion turbine. Even with DG running as baseload, 57% of electricity displaced will be simple cycle natural gas. Despite the retirement of some gas-fired steam units and the construction of many new gas turbine and combined cycle units, the marginal emissions from the system remain quite high (1.4 lb NO{sub x}/MWh on peak and 1.1 lb NO{sub x}/MWh baseload) compared to projected DG emissions. Consequently, additions of DG capacity will reduce emissions in Texas from power generation in 2012. Using the DG exhaust heat for combined heat and power provides an even greater benefit, since it eliminates further boiler emissions while adding none over what would be produced while generating electricity. Further studies are warranted concerning the robustness of the result with changes in fuel prices, demands, and mixes of power generating technology.

  9. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect (OSTI)

    David Deangelis; Rich Depuy; Debashis Dey; Georgia Karvountzi; Nguyen Minh; Max Peter; Faress Rahman; Pavel Sokolov; Deliang Yang

    2004-09-30T23:59:59.000Z

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC (HPGS) during the April to October 2004 reporting period in Task 2.3 (SOFC Scaleup for Hybrid and Fuel Cell Systems) under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL), entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. This study analyzes the performance and economics of power generation systems for central power generation application based on Solid Oxide Fuel Cell (SOFC) technology and fueled by natural gas. The main objective of this task is to develop credible scale up strategies for large solid oxide fuel cell-gas turbine systems. System concepts that integrate a SOFC with a gas turbine were developed and analyzed for plant sizes in excess of 20 MW. A 25 MW plant configuration was selected with projected system efficiency of over 65% and a factory cost of under $400/kW. The plant design is modular and can be scaled to both higher and lower plant power ratings. Technology gaps and required engineering development efforts were identified and evaluated.

  10. Distributed Generation Study/Emerling Farm | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model,DOE FacilityDimondale, Michigan:Emerling Farm < Distributed Generation Study

  11. Distributed Generation Study/Floyd Bennett | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model,DOE FacilityDimondale, Michigan:Emerling Farm < Distributed Generation

  12. Natural Language Generation for Nature Conservation: Automating Feedback to help Volunteers identify

    E-Print Network [OSTI]

    Siddharthan, Advaith

    Language Generation, Educational Application, Bumblebee Conser- vation, Citizen Science, Generating, including the use of websites and social media, to increase participation in "citizen science", which Science, University of Aberdeen, U.K. (2) Aberdeen Centre for Environmental Sustainability (ACES

  13. Time series power flow analysis for distribution connected PV generation.

    SciTech Connect (OSTI)

    Broderick, Robert Joseph; Quiroz, Jimmy Edward; Ellis, Abraham; Reno, Matthew J. [Georgia Institute of Technology, Atlanta, GA; Smith, Jeff [Electric Power Research Institute, Knoxville, TN; Dugan, Roger [Electric Power Research Institute, Knoxville, TN

    2013-01-01T23:59:59.000Z

    Distributed photovoltaic (PV) projects must go through an interconnection study process before connecting to the distribution grid. These studies are intended to identify the likely impacts and mitigation alternatives. In the majority of the cases, system impacts can be ruled out or mitigation can be identified without an involved study, through a screening process or a simple supplemental review study. For some proposed projects, expensive and time-consuming interconnection studies are required. The challenges to performing the studies are twofold. First, every study scenario is potentially unique, as the studies are often highly specific to the amount of PV generation capacity that varies greatly from feeder to feeder and is often unevenly distributed along the same feeder. This can cause location-specific impacts and mitigations. The second challenge is the inherent variability in PV power output which can interact with feeder operation in complex ways, by affecting the operation of voltage regulation and protection devices. The typical simulation tools and methods in use today for distribution system planning are often not adequate to accurately assess these potential impacts. This report demonstrates how quasi-static time series (QSTS) simulation and high time-resolution data can be used to assess the potential impacts in a more comprehensive manner. The QSTS simulations are applied to a set of sample feeders with high PV deployment to illustrate the usefulness of the approach. The report describes methods that can help determine how PV affects distribution system operations. The simulation results are focused on enhancing the understanding of the underlying technical issues. The examples also highlight the steps needed to perform QSTS simulation and describe the data needed to drive the simulations. The goal of this report is to make the methodology of time series power flow analysis readily accessible to utilities and others responsible for evaluating potential PV impacts.

  14. The Effect of Distributed Energy Resource Competition with Central Generation

    SciTech Connect (OSTI)

    Hadley, SW

    2003-12-10T23:59:59.000Z

    Distributed Energy Resource (DER) has been touted as a clean and efficient way to generate electricity at end-use sites, potentially allowing the exhaust heat to be put to good use as well. However, despite its environmental acceptability compared to many other types of generation, it has faced some disapproval because it may displace other, cleaner generation technologies. The end result could be more pollution than if the DER were not deployed. On the other hand, the DER may be competing against older power plants. If the DER is built then these other plants may be retired sooner, reducing their emissions. Or it may be that DER does not directly compete against either new or old plant capacity at the decision-maker level, and increased DER simply reduces the amount of time various plants operate. The key factor is what gets displaced if DER is added. For every kWh made by DER a kWh (or more with losses) of other production is not made. If enough DER is created, some power plants will get retired or not get built so not only their production but their capacity is displaced. Various characteristics of the power system in a region will influence how DER impacts the operation of the grid. The growth in demand in the region may influence whether new plants are postponed or old plants retired. The generation mix, including the fuel types, efficiencies, and emission characteristics of the plants in the region will factor into the overall competition. And public policies such as ease of new construction, emissions regulations, and fuel availability will also come into consideration.

  15. Automated Test Generation for Access Control Policies via Change-Impact Analysis

    E-Print Network [OSTI]

    Young, R. Michael

    Carolina State University Raleigh, NC, USA eemartin@ncsu.edu Tao Xie North Carolina State University outputs (in the form of responses) against expected ones. Unfortunately, manual test generation is tedious and manually generated tests are often not sufficient to exercise various policy behaviors. In this paper we

  16. IMPACT OF FUEL CELL BASED HYBRID DISTRIBUTED GENERATION IN AN ELECTRICAL DISTRIBUTION

    E-Print Network [OSTI]

    unknown authors

    Recent developments in distributed generation technologies have enabled new options for supplying electrical energy in remote and off-grid areas. The importance of fuel cells has increased during the past decade due to the extensive use of fossil fuels for electrical power has resulted in many negative consequences. Fuel cells are now closer to commercialization than past and they have the ability to fulfill all of the global power needs while meeting the economic and environmental expectations..The objective of this paper is to study the economic performance and operation of a fuel cell distributed generation and to provide an assessment of the economic issues associated in electrical network. In this study, with HOMER (Hybrid Optimization Model for Electric Renewables) software, NREL’s micro power optimization model performed a range of equipment options over varying constraints and sensitivities to optimize small power distribution systems. Its flexibility makes it useful in the evaluation of design issues in the planning and early decision-making phase of rural electrification projects. This study concludes that fuel cell systems appear competitive today if is connected with proposed hybrid DG in an AC distribution grid. The overall energy management strategy for coordinating the power flows among the different energy sources is presented with cost-effective approach.

  17. SOLID OXIDE FUEL CELL HYBRID SYSTEM FOR DISTRIBUTED POWER GENERATION

    SciTech Connect (OSTI)

    Kurt Montgomery; Nguyen Minh

    2003-08-01T23:59:59.000Z

    This report summarizes the work performed by Honeywell during the October 2001 to December 2001 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. The conceptual and demonstration system designs were proposed and analyzed, and these systems have been modeled in Aspen Plus. Work has also started on the assembly of dynamic component models and the development of the top-level controls requirements for the system. SOFC stacks have been fabricated and performance mapping initiated.

  18. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect (OSTI)

    Nguyen Minh

    2002-03-31T23:59:59.000Z

    This report summarizes the work performed by Honeywell during the January 2002 to March 2002 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. For this reporting period the following activities have been carried out: {lg_bullet} Conceptual system design trade studies were performed {lg_bullet} System-level performance model was created {lg_bullet} Dynamic control models are being developed {lg_bullet} Mechanical properties of candidate heat exchanger materials were investigated {lg_bullet} SOFC performance mapping as a function of flow rate and pressure was completed

  19. SOLID OXIDE FUEL CELL HYBRID SYSTEM FOR DISTRIBUTED POWER GENERATION

    SciTech Connect (OSTI)

    Unknown

    2002-03-01T23:59:59.000Z

    This report summarizes the work performed by Honeywell during the July 2001 to September 2001 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. An internal program kickoff was held at Honeywell in Torrance, CA. The program structure was outlined and the overall technical approach for the program was presented to the team members. Detail program schedules were developed and detailed objectives were defined. Initial work has begun on the system design and pressurized SOFC operation.

  20. Distributed generation capabilities of the national energy modeling system

    SciTech Connect (OSTI)

    LaCommare, Kristina Hamachi; Edwards, Jennifer L.; Marnay, Chris

    2003-01-01T23:59:59.000Z

    This report describes Berkeley Lab's exploration of how the National Energy Modeling System (NEMS) models distributed generation (DG) and presents possible approaches for improving how DG is modeled. The on-site electric generation capability has been available since the AEO2000 version of NEMS. Berkeley Lab has previously completed research on distributed energy resources (DER) adoption at individual sites and has developed a DER Customer Adoption Model called DER-CAM. Given interest in this area, Berkeley Lab set out to understand how NEMS models small-scale on-site generation to assess how adequately DG is treated in NEMS, and to propose improvements or alternatives. The goal is to determine how well NEMS models the factors influencing DG adoption and to consider alternatives to the current approach. Most small-scale DG adoption takes place in the residential and commercial modules of NEMS. Investment in DG ultimately offsets purchases of electricity, which also eliminates the losses associated with transmission and distribution (T&D). If the DG technology that is chosen is photovoltaics (PV), NEMS assumes renewable energy consumption replaces the energy input to electric generators. If the DG technology is fuel consuming, consumption of fuel in the electric utility sector is replaced by residential or commercial fuel consumption. The waste heat generated from thermal technologies can be used to offset the water heating and space heating energy uses, but there is no thermally activated cooling capability. This study consists of a review of model documentation and a paper by EIA staff, a series of sensitivity runs performed by Berkeley Lab that exercise selected DG parameters in the AEO2002 version of NEMS, and a scoping effort of possible enhancements and alternatives to NEMS current DG capabilities. In general, the treatment of DG in NEMS is rudimentary. The penetration of DG is determined by an economic cash-flow analysis that determines adoption based on the n umber of years to a positive cash flow. Some important technologies, e.g. thermally activated cooling, are absent, and ceilings on DG adoption are determined by some what arbitrary caps on the number of buildings that can adopt DG. These caps are particularly severe for existing buildings, where the maximum penetration for any one technology is 0.25 percent. On the other hand, competition among technologies is not fully considered, and this may result in double-counting for certain applications. A series of sensitivity runs show greater penetration with net metering enhancements and aggressive tax credits and a more limited response to lowered DG technology costs. Discussion of alternatives to the current code is presented in Section 4. Alternatives or improvements to how DG is modeled in NEMS cover three basic areas: expanding on the existing total market for DG both by changing existing parameters in NEMS and by adding new capabilities, such as for missing technologies; enhancing the cash flow analysis but incorporating aspects of DG economics that are not currently represented, e.g. complex tariffs; and using an external geographic information system (GIS) driven analysis that can better and more intuitively identify niche markets.

  1. Investment and Upgrade in Distributed Generation under Uncertainty

    SciTech Connect (OSTI)

    Siddiqui, Afzal; Maribu, Karl

    2008-08-18T23:59:59.000Z

    The ongoing deregulation of electricity industries worldwide is providing incentives for microgrids to use small-scale distributed generation (DG) and combined heat and power (CHP) applications via heat exchangers (HXs) to meet local energy loads. Although the electric-only efficiency of DG is lower than that of central-station production, relatively high tariff rates and the potential for CHP applications increase the attraction of on-site generation. Nevertheless, a microgrid contemplatingthe installation of gas-fired DG has to be aware of the uncertainty in the natural gas price. Treatment of uncertainty via real options increases the value of the investment opportunity, which then delays the adoption decision as the opportunity cost of exercising the investment option increases as well. In this paper, we take the perspective of a microgrid that can proceed in a sequential manner with DG capacity and HX investment in order to reduce its exposure to risk from natural gas price volatility. In particular, with the availability of the HX, the microgrid faces a tradeoff between reducing its exposure to the natural gas price and maximising its cost savings. By varying the volatility parameter, we find that the microgrid prefers a direct investment strategy for low levels of volatility and a sequential one for higher levels of volatility.

  2. A Model of U.S. Commercial Distributed Generation Adoption

    SciTech Connect (OSTI)

    LaCommare, Kristina Hamachi; Ryan Firestone; Zhou, Nan; Maribu,Karl; Marnay, Chris

    2006-01-10T23:59:59.000Z

    Small-scale (100 kW-5 MW) on-site distributed generation (DG) economically driven by combined heat and power (CHP) applications and, in some cases, reliability concerns will likely emerge as a common feature of commercial building energy systems over the next two decades. Forecasts of DG adoption published by the Energy Information Administration (EIA) in the Annual Energy Outlook (AEO) are made using the National Energy Modeling System (NEMS), which has a forecasting module that predicts the penetration of several possible commercial building DG technologies over the period 2005-2025. NEMS is also used for estimating the future benefits of Department of Energy research and development used in support of budget requests and management decisionmaking. The NEMS approach to modeling DG has some limitations, including constraints on the amount of DG allowed for retrofits to existing buildings and a small number of possible sizes for each DG technology. An alternative approach called Commercial Sector Model (ComSeM) is developed to improve the way in which DG adoption is modeled. The approach incorporates load shapes for specific end uses in specific building types in specific regions, e.g., cooling in hospitals in Atlanta or space heating in Chicago offices. The Distributed Energy Resources Customer Adoption Model (DER-CAM) uses these load profiles together with input cost and performance DG technology assumptions to model the potential DG adoption for four selected cities and two sizes of five building types in selected forecast years to 2022. The Distributed Energy Resources Market Diffusion Model (DER-MaDiM) is then used to then tailor the DER-CAM results to adoption projections for the entire U.S. commercial sector for all forecast years from 2007-2025. This process is conducted such that the structure of results are consistent with the structure of NEMS, and can be re-injected into NEMS that can then be used to integrate adoption results into a full forecast.

  3. Central power generation versus distributed generation e An air quality assessment in the South Coast Air Basin of California

    E-Print Network [OSTI]

    Dabdub, Donald

    Keywords: Distributed generation Central generation Air quality modeling Reactivity a b s t r a c by the widespread installation of many stationary power generators close to the point of electricity use within from which electricity must be transmitted to end users. However, increasing electricity demand

  4. Distributed Generation Investment by a Microgrid under Uncertainty

    E-Print Network [OSTI]

    Siddiqui, Afzal

    2008-01-01T23:59:59.000Z

    Cost of Natural Gas Generation, p Figure 6. Normalised NetCost of Natural Gas Generation, p Figure 7. Wait InvestCost of Natural Gas Generation (US$/kWh e ), C Figure 8.

  5. Air Quality Impact of Distributed Generation of Electricity

    E-Print Network [OSTI]

    Jing, Qiguo

    2011-01-01T23:59:59.000Z

    of the near source air quality impact of distributedDabdub, D. , 2003. Urban Air quality impacts of distributedDabdub, D. , 2004. Urban Air quality impacts of distributed

  6. Fast, Automated, Scalable Generation of Textured 3D Models of Indoor Environments

    E-Print Network [OSTI]

    Zakhor, Avideh

    , Student Member, IEEE, Peter Cheng, and Avideh Zakhor, Fellow, IEEE Abstract--3D modeling of building- realistic models. We apply these techniques to several data sets of building interiors, including multi or missing, especially after several remodelings. Such scans can be used to generate building models

  7. Method and apparatus for anti-islanding protection of distributed generations

    DOE Patents [OSTI]

    Ye, Zhihong; John, Vinod; Wang, Changyong; Garces, Luis Jose; Zhou, Rui; Li, Lei; Walling, Reigh Allen; Premerlani, William James; Sanza, Peter Claudius; Liu, Yan; Dame, Mark Edward

    2006-03-21T23:59:59.000Z

    An apparatus for anti-islanding protection of a distributed generation with respect to a feeder connected to an electrical grid is disclosed. The apparatus includes a sensor adapted to generate a voltage signal representative of an output voltage and/or a current signal representative of an output current at the distributed generation, and a controller responsive to the signals from the sensor. The controller is productive of a control signal directed to the distributed generation to drive an operating characteristic of the distributed generation out of a nominal range in response to the electrical grid being disconnected from the feeder.

  8. Hybrid Control Network Intrusion Detection Systems for Automated Power Distribution Systems

    E-Print Network [OSTI]

    Parvania, Masood; Koutsandria, Georgia; Muthukumar, Vishak; Peisert, Sean; McParland, Chuck; Scaglione, Anna

    2014-01-01T23:59:59.000Z

    Security protocols against cyber attacks in the distributioncyber security weak- ness and system fragility of power distribution

  9. HYBRID CONTROL OF DISTRIBUTED GENERATORS CONNECTED TO WEAK RURAL NETWORKS TO MITIGATE VOLTAGE VARIATION

    E-Print Network [OSTI]

    Harrison, Gareth

    thermal power plants will increase the total and proportion of capacity of Distributed Generation (DG@iee.org; Robin.Wallace@ed.ac.uk ABSTRACT Distributed generators are normally operated in automatic power factor-constrained bi- directional power flow may cause unacceptable voltage fluctuations that would cause generator

  10. Fuel cell power plants in a distributed generator application

    SciTech Connect (OSTI)

    Smith, M.J. [International Fuel Cells Corp., South Windsor, CT (United States)

    1996-12-31T23:59:59.000Z

    ONSI`s (a subsidiary of International Fuel Cells Corporation) world wide fleet of 200-kW PC25{trademark} phosphoric acid fuel cell power plants which began operation early in 1992 has shown excellent performance and reliability in over 1 million hours of operation. This experience has verified the clean, quiet, reliable operation of the PC25 and confirmed its application as a distributed generator. Continuing product development efforts have resulted in a one third reduction of weight and volume as well as improved installation and operating characteristics for the PC25 C model. Delivery of this unit began in 1995. International Fuel Cells (IFC) continues its efforts to improve product design and manufacturing processes. This progress has been sustained at a compounded rate of 10 percent per year since the late 1980`s. These improvements will permit further reductions in the initial cost of the power plant and place increased emphasis on market development as the pacing item in achieving business benefits from the PC25 fuel cell. Derivative product opportunities are evolving with maturation of the technologies in a commercial environment. The recent announcement of Praxair, Inc., and IFC introducing a non-cryogenic hydrogen supply system utilizing IFC`s steam reformer is an example. 11 figs.

  11. Abstract--This paper proposes a distributed generator (DG) placement methodology based on newly defined term reactive

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    . Index Terms--Distributed generator (DG), reactive power loadability, solar, voltage regulation, wind generator. I. INTRODUCTION istributed generation based on renewable energy sources offers a promising

  12. Greenhouse Gas Abatement with Distributed Generation in California's Commercial Buildings

    SciTech Connect (OSTI)

    Stadler, Michael; Marnay, Chris; Cardoso, Goncalo; Megel, Olivier; Siddiqui, Afzal; Lai, Judy

    2009-08-15T23:59:59.000Z

    Lawrence Berkeley National Laboratory (LBL) is working with the California Energy Commission (CEC) to determine the role of distributed generation (DG) in greenhouse gas reductions. The impact of DG on large industrial sites is well known, and mostly, the potentials are already harvested. In contrast, little is known about the impact of DG on commercial buildings with peak electric loads ranging from 100 kW to 5 MW. We examine how DG with combined heat and power (CHP) may be implemented within the context of a cost minimizing microgrid that is able to adopt and operate various smart energy technologies, such as thermal and photovoltaic (PV) on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We use a mixed-integer linear program (MILP) that has the minimization of a site's annual energy costs as objective. Using 138 representative commercial sites in California (CA) with existing tariff rates and technology data, we find the greenhouse gas reduction potential for California's commercial sector. This paper shows results from the ongoing research project and finished work from a two year U.S. Department of Energy research project. To show the impact of the different technologies on CO2 emissions, several sensitivity runs for different climate zones within CA with different technology performance expectations for 2020 were performed. The considered sites can contribute between 1 Mt/a and 1.8 Mt/a to the California Air Resources Board (CARB) goal of 6.7Mt/a CO2 abatement potential in 2020. Also, with lower PV and storage costs as well as consideration of a CO2 pricing scheme, our results indicate that PV and electric storage adoption can compete rather than supplement each other when the tariff structure and costs of electricity supply have been taken into consideration. To satisfy the site's objective of minimizing energy costs, the batteries will be charged also by CHP systems during off-peak and mid-peak hours and not only by PV during sunny on-peak hours.

  13. Methodology The electricity generation and distribution network in the Western United States is

    E-Print Network [OSTI]

    Hall, Sharon J.

    Methodology The electricity generation and distribution network in the Western United States is comprised of power plants, electric utilities, electrical transformers, transmission and distribution infrastructure, etc. We conceptualize the system as a transportation network with resources (electricity

  14. Micro-grid operation of inverter based distributed generation with voltage and frequency dependent loads

    E-Print Network [OSTI]

    Zeineldin, H. H.

    Distribution systems are experiencing increasing penetration of distributed generation (DG). One attractive option is to use the available DG capacity during utility outages by forming planned micro-grids. Load sharing ...

  15. Dynamic equivalencing of distribution network with embedded generation 

    E-Print Network [OSTI]

    Feng, Xiaodan Selina

    2012-06-25T23:59:59.000Z

    Renewable energy generation will play an important role in solving the climate change problem. With renewable electricity generation increasing, there will be some significant changes in electric power systems, ...

  16. Evaluation of Representative Smart Grid Investment Grant Project Technologies: Distributed Generation

    SciTech Connect (OSTI)

    Singh, Ruchi; Vyakaranam, Bharat GNVSR

    2012-02-14T23:59:59.000Z

    This document is one of a series of reports estimating the benefits of deploying technologies similar to those implemented on the Smart Grid Investment Grant (SGIG) projects. Four technical reports cover the various types of technologies deployed in the SGIG projects, distribution automation, demand response, energy storage, and renewables integration. A fifth report in the series examines the benefits of deploying these technologies on a national level. This technical report examines the impacts of addition of renewable resources- solar and wind in the distribution system as deployed in the SGIG projects.

  17. Smoothing the Eects of Renewable Generation on the Distribution Grid

    E-Print Network [OSTI]

    Naud, Paul S.

    2014-01-01T23:59:59.000Z

    to Grid by Paul Naud Renewable electrical power sourcessystem based on various renewable energy resources. InCRUZ Smoothing the Effects of Renewable Generation on the

  18. Distributed Generation Investment by a Microgrid Under Uncertainty

    E-Print Network [OSTI]

    Siddiqui, Afzal; Marnay, Chris

    2006-01-01T23:59:59.000Z

    electricity markets , PhD thesis, University of California, Berkeley, CA, USA,USA, 1994. Joskow PL, Productivity growth and technical change in the generation of electricity,

  19. Future of Distributed Generation and IEEE 1547 (Presentation...

    Office of Scientific and Technical Information (OSTI)

    new boundary issues and requirements, islanding issues, and how it impacts distributed wind. times redirected to final destination ShortURL Code Published Current state Most...

  20. Future of Distributed Generation and IEEE 1547 (Presentation)

    SciTech Connect (OSTI)

    Preus, R.

    2014-06-01T23:59:59.000Z

    This presentation discusses the background on IEEE 1547, including its purpose, changes, new boundary issues and requirements, islanding issues, and how it impacts distributed wind.

  1. Control and Analysis of Droop and Reverse Droop Controllers for Distributed Generations

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    Control and Analysis of Droop and Reverse Droop Controllers for Distributed Generations Dan Wu1 University, P. R. China ftang_nego@126.com Abstract--This paper addresses control and analysis of droop and reverse droop control for distributed generations (DG). The droop control is well known applied

  2. Self-triggered Communication Enabled Control of Distributed Generation in Microgrids

    E-Print Network [OSTI]

    Mazumder, Sudip K.

    1 Self-triggered Communication Enabled Control of Distributed Generation in Microgrids Muhammad. I. INTRODUCTION Effective integration of multiple distributed generation (DG) units in microgrids. Conventionally the secondary control in a microgrid is based on a centralized control structure using periodic

  3. 1170 IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 28, NO. 2, MAY 2013 Independent Distributed Generation Planning

    E-Print Network [OSTI]

    Mohsenian-Rad, Hamed

    -scale electric generation facilities to participate in distributed generation (DG) with few requirements on power-purchase1170 IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 28, NO. 2, MAY 2013 Independent Distributed is maximized via procuring power from DGs and the market at a minimum expense. On the other hand, each DG unit

  4. Power Flow Analysis Algorithm for Islanded LV Microgrids Including Distributed Generator Units with

    E-Print Network [OSTI]

    Chaudhary, Sanjay

    Power Flow Analysis Algorithm for Islanded LV Microgrids Including Distributed Generator Units With larger portion of growing electricity demand which is being fed through distributed generation (DG power system. Being able to operate in both grid-connected and islanded mode, a microgrid manages

  5. Reactive power management of distribution networks with wind generation for improving voltage stability

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    -loadability Reactive power margin Wind turbine a b s t r a c t This paper proposes static and dynamic VAR planningReactive power management of distribution networks with wind generation for improving voltage February 2013 Available online Keywords: Composite load Distributed generation D-STATCOM Q

  6. OPTIMAL DISTRIBUTED POWER GENERATION UNDER NETWORK LOAD CONSTRAINTS,

    E-Print Network [OSTI]

    Frank, Jason

    of novel components for decentral power generation (solar panels, small wind turbines and heat pumps). This gives rise to the question how many units of each type (solar panel, small wind turbine or central-producers. Decentralized Power Generation (DPG) refers to an electric power source such as solar, wind or combined heat

  7. Complete Automation of Future Grid for Optimal Real-Time Distribution of Renewables

    E-Print Network [OSTI]

    Loudon, Catherine

    integrates tie-set graph theory with an intelligent agent system, is presented to distribute renewable energy]-[3]. The renewable energy resource applications will offset dependence of fossil fuels, and provide green power options for atmospheric emissions curtailment. However, harvesting renewable energies may be unstable due

  8. Distributed Integrated Scheduling in Automated Manufacturing Systems with Transient Machine Failures

    E-Print Network [OSTI]

    Wedde, Horst F.

    as for a larger variety of products. At the same time better adaptability of transportation planning, electronic negotiations 1. Introduction Distributed Computer Control for Just-in- Time Production and production flows. The Just-in-Time method has not yet been used in computer-controlled manufacturing systems

  9. Quantifying the Air Pollution Exposure Consequences of Distributed Electricity Generation

    E-Print Network [OSTI]

    Heath, Garvin A.; Granvold, Patrick W.; Hoats, Abigail S.; Nazaroff, William W

    2005-01-01T23:59:59.000Z

    2: L A City, DWP Valley Generating 1: Hunters Point 2: PG &E Co, Hunters Point Power 1: SDG & E Co/Kearny Mesa GT 2:Angeles ST(4) BF(2) Hunters Point San Francisco NG, Diesel

  10. March 2015 Most Viewed Documents for Power Generation And Distribution...

    Office of Scientific and Technical Information (OSTI)

    Methods for Power Distribution Systems: Final Report Tom McDermott (2010) 67 Frequency Control Concerns in the North American Electric Power System Kirby, B.J. (2003) 64 A...

  11. Smoothing the Eects of Renewable Generation on the Distribution Grid

    E-Print Network [OSTI]

    Naud, Paul S.

    2014-01-01T23:59:59.000Z

    Fortunately, inverter data from a customer with a PV systemsystem, in series with a PV array and ahead of the inverter,PV is fed into an inverter to feed energy into the distribution system.

  12. Random Boolean networks with number of parents generated by certain probability distributions

    E-Print Network [OSTI]

    Matache, Dora

    Random Boolean networks with number of parents generated by certain probability distributions Ray A following a Power Law distribution. Others have examined how highly connected networks use a Popularity network where the number of parents are obtained using a Power Law distribution and are connected based

  13. Distributed Generation Dispatch Optimization under VariousElectricity Tariffs

    SciTech Connect (OSTI)

    Firestone, Ryan; Marnay, Chris

    2007-05-01T23:59:59.000Z

    The on-site generation of electricity can offer buildingowners and occupiers financial benefits as well as social benefits suchas reduced grid congestion, improved energy efficiency, and reducedgreenhouse gas emissions. Combined heat and power (CHP), or cogeneration,systems make use of the waste heat from the generator for site heatingneeds. Real-time optimal dispatch of CHP systems is difficult todetermine because of complicated electricity tariffs and uncertainty inCHP equipment availability, energy prices, and system loads. Typically,CHP systems use simple heuristic control strategies. This paper describesa method of determining optimal control in real-time and applies it to alight industrial site in San Diego, California, to examine: 1) the addedbenefit of optimal over heuristic controls, 2) the price elasticity ofthe system, and 3) the site-attributable greenhouse gas emissions, allunder three different tariff structures. Results suggest that heuristiccontrols are adequate under the current tariff structure and relativelyhigh electricity prices, capturing 97 percent of the value of thedistributed generation system. Even more value could be captured bysimply not running the CHP system during times of unusually high naturalgas prices. Under hypothetical real-time pricing of electricity,heuristic controls would capture only 70 percent of the value ofdistributed generation.

  14. Distributed Generation Investment by a Microgrid under Uncertainty++++ Afzal Siddiqui

    E-Print Network [OSTI]

    Guillas, Serge

    , CA 94720-8163, USA, c_marnay@lbl.gov ABSTRACT. This paper examines a California-based microgrid-term natural gas generation cost is stochastic, we initially assume that the microgrid may purchase electricity is not attractive. By allowing the electricity price to be stochastic, we next determine an investment threshold

  15. Optimal distributed power generation under network load constraints

    E-Print Network [OSTI]

    Utrecht, Universiteit

    wind turbines and heat pumps). This gives rise to the question how many units of each type (solar panel, mainly because of the development of novel components for decentral power generation (solar panels, small (DPG) refers to an electric power source such as solar, wind or combined heat power (CHP) connected

  16. Distributed Power Generation: Requirements and Recommendations for an ICT Architecture

    E-Print Network [OSTI]

    Appelrath, Hans-Jürgen

    . In the future of energy markets, the distributed energy production through wind and hydroelectric power plants. Some of these are sustainable (wind and hydroelectric power plants, solar cells), some are controllable, one has to distinguish between two in principle different products: consumption power and balance

  17. Integration of Renewables Via Demand Management: Highly Dispatchable and Distributed Demand Response for the Integration of Distributed Generation

    SciTech Connect (OSTI)

    None

    2012-02-11T23:59:59.000Z

    GENI Project: AutoGrid, in conjunction with Lawrence Berkeley National Laboratory and Columbia University, will design and demonstrate automated control software that helps manage real-time demand for energy across the electric grid. Known as the Demand Response Optimization and Management System - Real-Time (DROMS-RT), the software will enable personalized price signal to be sent to millions of customers in extremely short timeframes—incentivizing them to alter their electricity use in response to grid conditions. This will help grid operators better manage unpredictable demand and supply fluctuations in short time-scales —making the power generation process more efficient and cost effective for both suppliers and consumers. DROMS-RT is expected to provide a 90% reduction in the cost of operating demand response and dynamic pricing Projects in the U.S.

  18. Study and Development of Anti-Islanding Control for Synchronous Machine-Based Distributed Generators: November 2001--March 2004

    SciTech Connect (OSTI)

    Ye, Z.

    2006-03-01T23:59:59.000Z

    This report summarizes the study and development of new active anti-islanding control schemes for synchronous machine-based distributed generators, including engine generators and gas turbines.

  19. The Value of Distributed Solar Electric Generation to San Antonio

    SciTech Connect (OSTI)

    Jones, Nic [Solar San Antonio, TX (United States); Norris, Ben [Clean Power Research, Napa, CA (United States); Meyer, Lisa [City of San Antonio, TX (United States)

    2013-02-14T23:59:59.000Z

    This report presents an analysis of value provided by grid-connected, distributed PV in San Antonio from a utility perspective. The study quantified six value components, summarized in Table ES- 1. These components represent the benefits that accrue to the utility, CPS Energy, in accepting solar onto the grid. This analysis does not treat the compensation of value, policy objectives, or cost-effectiveness from the retail consumer perspective.

  20. Automated Data Collection for Determining Statistical Distributions of Module Power Undergoing Potential-Induced Degradation: Preprint

    SciTech Connect (OSTI)

    Hacke, P.; Spataru, S.

    2014-08-01T23:59:59.000Z

    We propose a method for increasing the frequency of data collection and reducing the time and cost of accelerated lifetime testing of photovoltaic modules undergoing potential-induced degradation (PID). This consists of in-situ measurements of dark current-voltage curves of the modules at elevated stress temperature, their use to determine the maximum power at 25 degrees C standard test conditions (STC), and distribution statistics for determining degradation rates as a function of stress level. The semi-continuous data obtained by this method clearly show degradation curves of the maximum power, including an incubation phase, rates and extent of degradation, precise time to failure, and partial recovery. Stress tests were performed on crystalline silicon modules at 85% relative humidity and 60 degrees C, 72 degrees C, and 85 degrees C. Activation energy for the mean time to failure (1% relative) of 0.85 eV was determined and a mean time to failure of 8,000 h at 25 degrees C and 85% relative humidity is predicted. No clear trend in maximum degradation as a function of stress temperature was observed.

  1. Investigation of anti-islanding schemes for utility interconnection of distributed fuel cell powered generations 

    E-Print Network [OSTI]

    Jeraputra, Chuttchaval

    2006-04-12T23:59:59.000Z

    The rapid emergence of distributed fuel cell powered generations (DFPGs) operating in parallel with utility has brought a number of technical concerns as more DFPGs are connected to utility grid. One of the most challenging ...

  2. Applying epoch-era analysis for homeowner selection of distributed generation power systems

    E-Print Network [OSTI]

    Piña, Alexander L

    2014-01-01T23:59:59.000Z

    The current shift from centralized energy generation to a more distributed model has opened a number of choices for homeowners to provide their own power. While there are a number of systems to purchase, there are no tools ...

  3. Distributed generation and demand side management : applications to transmission system operation 

    E-Print Network [OSTI]

    Hayes, Barry Patrick

    2013-07-01T23:59:59.000Z

    Electricity networks are undergoing a period of rapid change and transformation, with increased penetration levels of renewable-based distributed generation, and new influences on electricity end-use patterns from ...

  4. High Penetration Solar Distributed Generation Study on Oahu | Department of

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy ChinaofSchaefer To:Department of Energy CompletingPresentedGeneration FY13

  5. Distributed Generation System Characteristics and Costs in the Buildings Sector

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for On-Highway4,1,50022,3,,,,6,1,9,1,50022,3,,,,6,1,Decade Year-0E (2001)gasoline353/06) 2Yonthly Energy : bDistributed

  6. Distributed Generation Study/Harbec Plastics | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model,DOE FacilityDimondale, Michigan:Emerling Farm < Distributed

  7. Distributed Generation Study/Hudson Valley Community College | Open Energy

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model,DOE FacilityDimondale, Michigan:Emerling Farm < DistributedInformation

  8. Velocity distribution measurements in atomic beams generated using laser induced back-ablation

    E-Print Network [OSTI]

    Denning, A; Lee, S; Ammonson, M; Bergeson, S D

    2008-01-01T23:59:59.000Z

    We present measurements of the velocity distribution of calcium atoms in an atomic beam generated using a dual-stage laser back-ablation apparatus. Distributions are measured using a velocity selective Doppler time-of-flight technique. They are Boltzmann-like with rms velocities corresponding to temperatures above the melting point for calcium. Contrary to a recent report in the literature, this method does not generate a sub-thermal atomic beam.

  9. Fault Current Issues for Market Driven Power Systems with Distributed Generation

    E-Print Network [OSTI]

    are required for the selection of interruption devices, protective relays, and their coordination. Systems must Terms--Distributed / dispersed generation, power distri- bution, power system protection, fault in siting conventional generation ­ but, for whatever reason, protection engineers as well as transmission

  10. Distributed Load Demand Scheduling in Smart Grid to Minimize Electricity Generation Cost

    E-Print Network [OSTI]

    Pedram, Massoud

    is to perform demand side management (DSM) [1], which aims at matching the consum- ers' electricity demand between electricity consumption and generation. On the consumption side, electric demand ramps upDistributed Load Demand Scheduling in Smart Grid to Minimize Electricity Generation Cost Siyu Yue

  11. A forward microphysical model to predict the size-distribution parameters of laboratory generated (mimic)

    E-Print Network [OSTI]

    Oxford, University of

    A forward microphysical model to predict the size- distribution parameters of laboratory generated Interactions ­ Condensational Growth and Coagulation, Submitted for Indian Aerosol Science and Technology Microphysical Model for the UTLS (FAMMUS) is applied to predict the size-distribution parameters of laboratory

  12. A New Approach to Mitigate the Impact of Distributed Generation on the Overcurrent Protection Scheme of Radial Distribution Feeders

    E-Print Network [OSTI]

    Funmilayo, Hamed

    2010-01-14T23:59:59.000Z

    ........................................................5 2.3. Overcurrent Protection Coordination Rules ....................................................10 2.4. Distributed Generation (DG) in Radial Feeders ..............................................15 2.5. Radial Feeder with DG.............................................................................29 3.3. System Protection............................................................................................31 3.4. Interconnection Protection...............................................................................35 3.5. DG Unit...

  13. Utility/Industry Partnerships Involving Distributed Generation Technologies in Evolving Electricity Markets 

    E-Print Network [OSTI]

    Rastler, D. M.

    1997-01-01T23:59:59.000Z

    Wires Manage Wires defer capital Optimize Energy Services Not Utility Business Not Utility Business New Business Opportunities DISTRIBUTED GENERATION Distributed generation includes small gas turbines, micro-turbines, fuel cells, storage... Residential Single Family Multi Family 1-10 kW 15- 50 kW Ultra micro-turbines Stirling Engines Fuel Cells PEMFC SOFC PV BatterylUPS Remote Loads 5 kW - 1,000 kW IC engines Off Grid Diesel Engine Micro turbine Stirling Engines Distribution...

  14. Onsite Backup Generation and Interruption Insurance for Electricity Distribution Author(s): Joseph A. Doucet and Shmuel S. Oren

    E-Print Network [OSTI]

    Oren, Shmuel S.

    Onsite Backup Generation and Interruption Insurance for Electricity Distribution Author(s): Joseph customerownedonsitebackupdecisionswillpre-emptthe utility'splan to mitigatecompensationpaymentsbyprovidingonsitebackup generation access to The Energy Journal. http://www.jstor.org #12;Onsite Backup Generation and Interruption

  15. Key factors affecting voltage oscillations of distribution networks with distributed generation and induction motor loads

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    of distributed energy sources such as, combined heat and power (CHP), wind, solar, and fuel cells, are expected and IT, The University of New South Wales, Canberra, ACT 2600, Australia b Future Grid Research Centre, The University of Melbourne, Parkville, VIC 3010, Australia c Griffith School of Engineering, Griffith University

  16. Distributed Generation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    at customer sites to address peak load. 2 Using these resources could reduce required installed capacity and would increase the operating reserve margins for the network,...

  17. Fuel Cell Generation in Geo-Distributed Cloud Services: A Quantitative Study

    E-Print Network [OSTI]

    Li, Baochun

    Fuel Cell Generation in Geo-Distributed Cloud Services: A Quantitative Study Zhi Zhou1 Fangming Liu of fuel cell energy in cloud computing, yet it is unclear what and how much benefit it may bring. This paper, for the first time, attempts to quantitatively examine the benefits brought by fuel cell

  18. Published in IET Generation, Transmission & Distribution Received on 8th July 2013

    E-Print Network [OSTI]

    Fu, Yong

    , in a practical power system, the transmission topology can change as a result of maintenance and network network topology in an electric power system. The modelling is accomplished in a coordinatedPublished in IET Generation, Transmission & Distribution Received on 8th July 2013 Revised on 31st

  19. Agent-Based Simulation of Distribution Systems with High Penetration of Photovoltaic Generation

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    of strategic trading in restructured wholesale power markets with congestion managed by locational marginal when coupled with increased price-sensitivity of demand as realized through demand response, demand dispatch, and/or price-sensitive demand bidding. Index Terms--Distributed power generation, multiagent sys

  20. Published in IET Generation, Transmission & Distribution Received on 5th October 2012

    E-Print Network [OSTI]

    Qu, Zhihua

    , and the system reliability is improved. The simulation results verify the effectiveness of the proposed secondary networks reduce the system reliability. More reliable and sparse communication networks can be accommodated of multiple photovoltaic generators in a power distribution system [16]. Networked multi-agent systems have

  1. Operation and Control of Distribution Systems with high level integration of Renewable Generation units

    E-Print Network [OSTI]

    Bak-Jensen, Birgitte

    models Probabilistic methodologies are being applied to power system analysis since 70' [9] becauseOperation and Control of Distribution Systems with high level integration of Renewable Generation. Diagonal 649 Pavelló A, 08028 Barcelona, Spain Summary Traditional power systems have a hierarchical

  2. Abstract--Distributed generation (DG) has brought great attention from the power community, especially

    E-Print Network [OSTI]

    Catholic University of Chile (Universidad Católica de Chile)

    generation and DFACTS (distribution network Flexible AC Transmission System). In these researches, especially when it is associated with renewable energy sources, as a sustainable energy alternative. Some DG applications, especially on high penetration levels, may have adverse impact on the transmission

  3. Generating Structurally Complex Test Cases by Data Mutation: A Case Study of Testing an Automated Modelling Tool

    E-Print Network [OSTI]

    Zhu, Hong

    - 1 - Generating Structurally Complex Test Cases by Data Mutation: A Case Study of Testing Brookes University, Oxford OX33 1HX, UK Email: hzhu@brookes.ac.uk ABSTRACT Generation of adequate test cases is difficult and expensive, especially for testing software systems whose input is structurally

  4. Test Automation Ant JUnit Test Automation

    E-Print Network [OSTI]

    Mousavi, Mohammad

    Test Automation Ant JUnit Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2012 Mousavi: Test Automation #12;Test Automation Ant JUnit Outline Test Automation Ant JUnit Mousavi: Test Automation #12;Test Automation Ant JUnit Why? Challenges of Manual Testing

  5. Competitive Bidding Process for Electric Distribution Companies’ Procurement of Default and Back-up Electric Generation Services (Connecticut)

    Broader source: Energy.gov [DOE]

    Electric distribution companies shall utilize a competitive bidding process for electric generation services. The Department of Public Utility Control will be responsible for setting the criteria...

  6. Abstract--Recently, there is an increasing interest in using distributed generators (DGs) not only to inject power into the

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    1 1 Abstract--Recently, there is an increasing interest in using distributed generators (DGs, it is well-known that the Distributed Generators (DGs) often consist of a prime mover connected through-frame control method for voltage unbalance compensation in an islanded microgrid is proposed. This method

  7. Soil water and particle size distribution influence laboratory-generated PM10 Nicholaus M. Madden a,*, Randal J. Southard a

    E-Print Network [OSTI]

    Ahmad, Sajjad

    Soil water and particle size distribution influence laboratory-generated PM10 Nicholaus M. Madden a Soil particle size distribution Soil water content a b s t r a c t Management of soils to reduce earlier work of predicting tillage-generated dust emissions based on soil properties. We focus

  8. Ionic Liquids for Utilization of Waste Heat from Distributed Power Generation Systems

    SciTech Connect (OSTI)

    Joan F. Brennecke; Mihir Sen; Edward J. Maginn; Samuel Paolucci; Mark A. Stadtherr; Peter T. Disser; Mike Zdyb

    2009-01-11T23:59:59.000Z

    The objective of this research project was the development of ionic liquids to capture and utilize waste heat from distributed power generation systems. Ionic Liquids (ILs) are organic salts that are liquid at room temperature and they have the potential to make fundamental and far-reaching changes in the way we use energy. In particular, the focus of this project was fundamental research on the potential use of IL/CO2 mixtures in absorption-refrigeration systems. Such systems can provide cooling by utilizing waste heat from various sources, including distributed power generation. The basic objectives of the research were to design and synthesize ILs appropriate for the task, to measure and model thermophysical properties and phase behavior of ILs and IL/CO2 mixtures, and to model the performance of IL/CO2 absorption-refrigeration systems.

  9. A SIP-based Home Automation Platform: an Experimental Study

    E-Print Network [OSTI]

    Boyer, Edmond

    A SIP-based Home Automation Platform: an Experimental Study Benjamin Bertran, Charles Consel INRIA automation applications that consist of heterogeneous, distributed entities. We describe how SIP fulfills the requirements of home automation; we present the resulting architecture of a home automation system; and, we

  10. Design of a 2.5kW Low Temperature Stirling Engine for Distributed Solar Thermal Generation

    E-Print Network [OSTI]

    Sanders, Seth

    Design of a 2.5kW Low Temperature Stirling Engine for Distributed Solar Thermal Generation Mike He on the design of a Stirling engine for distributed solar thermal ap- plications. In particular, we design for experimentation. Stirling engines can have broad significance and technological advantages for distributed

  11. SIZE DISTRIBUTION AND RATE OF PRODUCTION OF AIRBORNE PARTICULATE MATTER GENERATED DURING METAL CUTTING

    SciTech Connect (OSTI)

    M.A. Ebadian, Ph.D.; S.K. Dua, Ph.D., C.H.P.; Hillol Guha, Ph.D.

    2001-01-01T23:59:59.000Z

    During deactivation and decommissioning activities, thermal cutting tools, such as plasma torch, laser, and gasoline torch, are used to cut metals. These activities generate fumes, smoke and particulates. These airborne species of matter, called aerosols, may be inhaled if suitable respiratory protection is not used. Inhalation of the airborne metallic aerosols has been reported to cause ill health effects, such as acute respiratory syndrome and chromosome damage in lymphocytes. In the nuclear industry, metals may be contaminated with radioactive materials. Cutting these metals, as in size reduction of gloveboxes and tanks, produces high concentrations of airborne transuranic particles. Particles of the respirable size range (size < 10 {micro}m) deposit in various compartments of the respiratory tract, the fraction and the site in the respiratory tract depending on the size of the particles. The dose delivered to the respiratory tract depends on the size distribution of the airborne particulates (aerosols) and their concentration and radioactivity/toxicity. The concentration of airborne particulate matter in an environment is dependent upon the rate of their production and the ventilation rate. Thus, measuring aerosol size distribution and generation rate is important for (1) the assessment of inhalation exposures of workers, (2) the selection of respiratory protection equipment, and (3) the design of appropriate filtration systems. Size distribution of the aerosols generated during cutting of different metals by plasma torch was measured. Cutting rates of different metals, rate of generation of respirable mass, as well as the fraction of the released kerf that become respirable were determined. This report presents results of these studies. Measurements of the particles generated during cutting of metal plates with a plasma arc torch revealed the presence of particles with mass median aerodynamic diameters of particles close to 0.2 {micro}m, arising from condensation of vaporized material and subsequent rapid formation of aggregates. Particles of larger size, resulting from ejection of melted material or fragments from the cutting zone, were also observed. This study presents data regarding the metal cutting rate, particle size distribution, and their generation rate, while using different cutting tools and metals. The study shows that respirable particles constitute only a small fraction of the released kerf.

  12. Making the Economic Case for Small-Scale Distributed Wind -- A Screening for Distributed Generation Wind Opportunities: Preprint

    SciTech Connect (OSTI)

    Kandt, A.; Brown, E.; Dominick, J.; Jurotich, T.

    2007-06-01T23:59:59.000Z

    This study was an offshoot of a previous assessment, which examined the potential for large-scale, greater than 50 MW, wind development on occupied federal agency lands. The study did not find significant commercial wind development opportunities, primarily because of poor wind resource on available and appropriately sized land areas or land use or aesthetic concerns. The few sites that could accommodate a large wind farm failed to have transmission lines in optimum locations required to generate power at competitive wholesale prices. The study did identify a promising but less common distributed generation (DG) development option. This follow-up study documents the NREL/Global Energy Concepts team efforts to identify economic DG wind projects at a select group of occupied federal sites. It employs a screening strategy based on project economics that go beyond quantity of windy land to include state and utility incentives as well as the value of avoided power purchases. It attempts to account for the extra costs and difficulties associated with small projects through the use of project scenarios that are more compatible with federal facilities and existing land uses. These benefits and barriers of DG are discussed, and the screening methodology and results are included. The report concludes with generalizations about the screening method and recommendations for improvement and other potential applications for this methodology.

  13. GREENHOUSE GAS REDUCTION POTENTIAL WITH COMBINED HEAT AND POWER WITH DISTRIBUTED GENERATION PRIME MOVERS - ASME 2012

    SciTech Connect (OSTI)

    Curran, Scott [ORNL; Theiss, Timothy J [ORNL; Bunce, Michael [ORNL

    2012-01-01T23:59:59.000Z

    Pending or recently enacted greenhouse gas regulations and mandates are leading to the need for current and feasible GHG reduction solutions including combined heat and power (CHP). Distributed generation using advanced reciprocating engines, gas turbines, microturbines and fuel cells has been shown to reduce greenhouse gases (GHG) compared to the U.S. electrical generation mix due to the use of natural gas and high electrical generation efficiencies of these prime movers. Many of these prime movers are also well suited for use in CHP systems which recover heat generated during combustion or energy conversion. CHP increases the total efficiency of the prime mover by recovering waste heat for generating electricity, replacing process steam, hot water for buildings or even cooling via absorption chilling. The increased efficiency of CHP systems further reduces GHG emissions compared to systems which do not recover waste thermal energy. Current GHG mandates within the U.S Federal sector and looming GHG legislation for states puts an emphasis on understanding the GHG reduction potential of such systems. This study compares the GHG savings from various state-of-the- art prime movers. GHG reductions from commercially available prime movers in the 1-5 MW class including, various industrial fuel cells, large and small gas turbines, micro turbines and reciprocating gas engines with and without CHP are compared to centralized electricity generation including the U.S. mix and the best available technology with natural gas combined cycle power plants. The findings show significant GHG saving potential with the use of CHP. Also provided is an exploration of the accounting methodology for GHG reductions with CHP and the sensitivity of such analyses to electrical generation efficiency, emissions factors and most importantly recoverable heat and thermal recovery efficiency from the CHP system.

  14. Ultrashort laser ablation of bulk copper targets: Dynamics and size distribution of the generated nanoparticles

    SciTech Connect (OSTI)

    Tsakiris, N.; Gill-Comeau, M.; Lewis, L. J. [Département de Physique et Regroupement Québécois sur les Matériaux de Pointe (RQMP), Université de Montréal, C.P. 6128, Succursale Centre-Ville, Montréal, Québec H3C 3J7 (Canada); Anoop, K. K.; Ausanio, G.; Bruzzese, R.; Amoruso, S., E-mail: amoruso@na.infn.it [Dipartimento di Fisica, Università degli Studi di Napoli Federico II and CNR-SPIN, Complesso Universitario di Monte S. Angelo, Via Cintia, I-80126 Napoli (Italy)

    2014-06-28T23:59:59.000Z

    We address the role of laser pulse fluence on expansion dynamics and size distribution of the nanoparticles produced by irradiating a metallic target with an ultrashort laser pulse in a vacuum, an issue for which contrasting indications are present in the literature. To this end, we have carried out a combined theoretical and experimental analysis of laser ablation of a bulk copper target with ?50 fs, 800?nm pulses, in an interval of laser fluencies going from few to several times the ablation threshold. On one side, molecular dynamics simulations, with two-temperature model, describe the decomposition of the material through the analysis of the evolution of thermodynamic trajectories in the material phase diagram, and allow estimating the size distribution of the generated nano-aggregates. On the other side, atomic force microscopy of less than one layer nanoparticles deposits on witness plates, and fast imaging of the nanoparticles broadband optical emission provide the corresponding experimental characterization. Both experimental and numerical findings agree on a size distribution characterized by a significant fraction (?90%) of small nanoparticles, and a residual part (?10%) spanning over a rather large size interval, evidencing a weak dependence of the nanoparticles sizes on the laser pulse fluence. Numerical and experimental findings show a good degree of consistency, thus suggesting that modeling can realistically support the search for experimental methods leading to an improved control over the generation of nanoparticles by ultrashort laser ablation.

  15. Optimizing Geographic Allotment of Photovoltaic Capacity in a Distributed Generation Setting: Preprint

    SciTech Connect (OSTI)

    Urquhart, B.; Sengupta, M.; Keller, J.

    2012-09-01T23:59:59.000Z

    A multi-objective optimization was performed to allocate 2MW of PV among four candidate sites on the island of Lanai such that energy was maximized and variability in the form of ramp rates was minimized. This resulted in an optimal solution set which provides a range of geographic allotment alternatives for the fixed PV capacity. Within the optimal set, a tradeoff between energy produced and variability experienced was found, whereby a decrease in variability always necessitates a simultaneous decrease in energy. A design point within the optimal set was selected for study which decreased extreme ramp rates by over 50% while only decreasing annual energy generation by 3% over the maximum generation allocation. To quantify the allotment mix selected, a metric was developed, called the ramp ratio, which compares ramping magnitude when all capacity is allotted to a single location to the aggregate ramping magnitude in a distributed scenario. The ramp ratio quantifies simultaneously how much smoothing a distributed scenario would experience over single site allotment and how much a single site is being under-utilized for its ability to reduce aggregate variability. This paper creates a framework for use by cities and municipal utilities to reduce variability impacts while planning for high penetration of PV on the distribution grid.

  16. Decoding the `Nature Encoded' Messages for Distributed Energy Generation Control in Microgrid

    E-Print Network [OSTI]

    Gong, Shuping; Lai, Lifeng; Qiu, Robert C

    2010-01-01T23:59:59.000Z

    The communication for the control of distributed energy generation (DEG) in microgrid is discussed. Due to the requirement of realtime transmission, weak or no explicit channel coding is used for the message of system state. To protect the reliability of the uncoded or weakly encoded messages, the system dynamics are considered as a `nature encoding' similar to convolution code, due to its redundancy in time. For systems with or without explicit channel coding, two decoding procedures based on Kalman filtering and Pearl's Belief Propagation, in a similar manner to Turbo processing in traditional data communication systems, are proposed. Numerical simulations have demonstrated the validity of the schemes, using a linear model of electric generator dynamic system.

  17. Onsite Distributed Generation Systems For Laboratories, Laboratories for the 21st Century: Best Practices (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2011-09-01T23:59:59.000Z

    This guide provides general information on implementing onsite distributed generation systems in laboratory environments. Specific technology applications, general performance information, and cost data are provided to educate and encourage laboratory energy managers to consider onsite power generation or combined heat and power (CHP) systems for their facilities. After conducting an initial screening, energy managers are encouraged to conduct a detailed feasibility study with actual cost and performance data for technologies that look promising. Onsite distributed generation systems are small, modular, decentralized, grid-connected, or off-grid energy systems. These systems are located at or near the place where the energy is used. These systems are also known as distributed energy or distributed power systems. DG technologies are generally considered those that produce less than 20 megawatts (MW) of power. A number of technologies can be applied as effective onsite DG systems, including: (1) Diesel, natural gas, and dual-fuel reciprocating engines; (2) Combustion turbines and steam turbines; (3) Fuel cells; (4) Biomass heating; (5) Biomass combined heat and power; (6) Photovoltaics; and (7) Wind turbines. These systems can provide a number of potential benefits to an individual laboratory facility or campus, including: (1) High-quality, reliable, and potentially dispatchable power; (2) Low-cost energy and long-term utility cost assurance, especially where electricity and/or fuel costs are high; (3) Significantly reduced greenhouse gas (GHG) emissions. Typical CHP plants reduce onsite GHG by 40 to 60 percent; (4) Peak demand shaving where demand costs are high; (5) CHP where thermal energy can be used in addition to electricity; (6) The ability to meet standby power needs, especially where utility-supplied power is interrupted frequently or for long periods and where standby power is required for safety or emergencies; and (7) Use for standalone or off-grid systems where extending the grid is too expensive or impractical. Because they are installed close to the load, DG systems avoid some of the disadvantages of large, central power plants, such as transmission and distribution losses over long electric lines.

  18. A Post-Occupancy Monitored Evaluation of the Dimmable Lighting, Automated Shading, and Underfloor Air Distribution System in The New York Times Building

    E-Print Network [OSTI]

    2013-01-01T23:59:59.000Z

    15 4.1. LightingEvaluation of the Dimmable Lighting, Automated Shading, andcomparison EUI, kBtu/Gsf Lighting Heating Cooling Pumps/C

  19. Reliable, Low-Cost Distributed Generator/Utility System Interconnect: Final Subcontract Report, November 2001-March 2004

    SciTech Connect (OSTI)

    Ye, Z.; Walling, R.; Miller, N.; Du, P.; Nelson, K.; Li, L.; Zhou, R.; Garces, L.; Dame, M.

    2006-03-01T23:59:59.000Z

    This report summarizes the detailed study and development of new GE anti-islanding controls for two classes of distributed generation. One is inverter-interfaced, while the other is synchronous machine interfaced.

  20. Electronic copy available at: http://ssrn.com/abstract=2014738 Published: J. M. Pearce, "Expanding Photovoltaic Penetration with Residential Distributed Generation

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Photovoltaic Penetration with Residential Distributed Generation from Hybrid Solar Photovoltaic + Combined Heat.08.012 Expanding Photovoltaic Penetration with Residential Distributed Generation from Hybrid Solar Photovoltaic and power (CHP) systems has provided the opportunity for inhouse power backup of residentialscale

  1. Generating the local oscillator "locally" in continuous-variable quantum key distribution based on coherent detection

    E-Print Network [OSTI]

    Bing Qi; Pavel Lougovski; Raphael Pooser; Warren Grice; Miljko Bobrek

    2015-03-02T23:59:59.000Z

    Continuous-variable quantum key distribution (CV-QKD) protocols based on coherent detection have been studied extensively in both theory and experiment. In all the existing implementations of CV-QKD, both the quantum signal and the local oscillator (LO) are generated from the same laser and propagate through the insecure quantum channel. This arrangement may open security loopholes and also limit the potential applications of CV-QKD. In this paper, we propose and demonstrate a pilot-aided feedforward data recovery scheme which enables reliable coherent detection using a "locally" generated LO. Using two independent commercial laser sources and a spool of 25 km optical fiber, we construct a coherent communication system. The variance of the phase noise introduced by the proposed scheme is measured to be 0.04 (rad^2), which is small enough to enable secure key distribution. This technology also opens the door for other quantum communication protocols, such as the recently proposed measurement-device-independent (MDI) CV-QKD where independent light sources are employed by different users.

  2. Viability of Small Wind Distributed Generation for Farmers Who Irrigate (Poster)

    SciTech Connect (OSTI)

    Meadows, B.; Forsyth, T.; Johnson, S.; Healow, D.

    2010-05-01T23:59:59.000Z

    About 14% of U.S. farms are irrigated, representing 55 million acres of irrigated land. Irrigation on these farms is a major energy user in the United States, accounting for one-third of water withdrawals and 137 billion gallons per day. More than half of the Irrigation systems use electric energy. Wind energy can be a good choice for meeting irrigation energy needs. Nine of the top 10 irrigation states (California, Texas, Idaho, Arkansas, Colorado, Nebraska, Arizona, Kansas, Washington, and Oregon) have good to excellent wind resources. Many rural areas have sufficient wind speeds to make wind an attractive alternative, and farms and ranches can often install a wind energy system without impacting their ability to plant crops and graze livestock. Additionally, the rising and uncertain future costs of diesel, natural gas, and even electricity increase the potential effectiveness for wind energy and its predictable and competitive cost. In general, wind-powered electric generation systems generate more energy in the winter months than in the summer months when most crops need the water. Therefore, those states that have a supportive net metering policy can dramatically impact the viability of an onsite wind turbine. This poster presentation highlights case studies that show favorable and unfavorable policies that impact the growth of small wind in this important sector and demonstrate how net metering policies affect the viability of distributed wind generation for farmers who irrigate.

  3. Abstract--This paper presents the consequences and operating limitations of installing distributed generation (DG) to electric

    E-Print Network [OSTI]

    are required for the selection of interruption devices, protective relays, and their coordination. Systems must Terms--Distributed / dispersed generation, power distri- bution, power system protection, fault in siting conventional generation ­ but, for whatever reason, protection engineers as well as transmission

  4. Evaluating shortfalls in mixed-integer programming approaches for the optimal design and dispatch of distributed generation systems

    E-Print Network [OSTI]

    heat and power Fuel cells Building energy a b s t r a c t The distributed generation (DG) of combined Wisconsin, retrofitted with solid-oxide fuel cells (SOFCs) and a hot water storage tank. The simpler model of renewable or non- renewable sources of power generation (e.g., photovoltaic (PV) cells, fuel cells

  5. Abstract--The capacity of distributed generation (DG) is set to increase significantly with much of the plant connecting to

    E-Print Network [OSTI]

    Harrison, Gareth

    limiting network capability in absorbing new DG. Finally, it demonstrates the use of optimal power flow market. Index Terms-- distributed generation, optimal power flow, power distribution. I. INTRODUCTION O in England and Wales (18% in Scotland) is derived from renewable resources. With existing large hydro

  6. Panel on Microgrids Systems International Conference on System of Systems Engineering, April 16-18, 2007 San Antonio Abstract--Application of individual distributed generators can

    E-Print Network [OSTI]

    are included. Keywords: CHP, UPS, distributed generation, intentional islanding, inverters, microgrid, power vs-18, 2007 San Antonio Abstract--Application of individual distributed generators can cause as many problems as it may solve. A better way to realize the emerging potential of distributed generation is to take

  7. The distribution of Voronoi cells generated by Southern California earthquake epicenters

    E-Print Network [OSTI]

    Schoenberg, Frederic P; Barr, Christopher; Jungju Seo

    2007-01-01T23:59:59.000Z

    Continuous Univariate Distributions. 2nd ed. Wiley, Newfor the tapered Pareto distribution. Journal of AppliedWoods, J. (2003) On the distribution of wild?re sizes. Envi-

  8. Study of the longitudinal distribution of power generated in a random distributed feedback Raman fibre laser with unidirectional pumping

    SciTech Connect (OSTI)

    Churkin, D V; El-Taher, A E; Vatnik, I D; Babin, Sergei A

    2012-09-30T23:59:59.000Z

    The longitudinal distribution of the Stokes-component power in a Raman fibre laser with a random distributed feedback and unidirectional pumping is measured. The fibre parameters (linear loss and Rayleigh backscattering coefficient) are calculated based on the distributions obtained. A numerical model is developed to describe the lasing power distribution. The simulation results are in good agreement with the experimental data. (optical fibres, lasers and amplifiers. properties and applications)

  9. Spectroscopic measurement of ion temperature and ion velocity distributions in the flux-coil generated FRC

    SciTech Connect (OSTI)

    Gupta, D.; Gota, H.; Hayashi, R.; Kiyashko, V.; Morehouse, M.; Primavera, S. [Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States); Bolte, N. [Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States); Department of Physics and Astronomy, University of California, Irvine, California 92697 (United States); Marsili, P. [Department of Physics, University of Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Roche, T. [Department of Physics and Astronomy, University of California, Irvine, California 92697 (United States); Wessel, F. [Department of Physics and Astronomy, University of California, Irvine, California 92697 (United States); Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States)

    2010-10-15T23:59:59.000Z

    One aim of the flux-coil generated field reversed configuration at Tri Alpha Energy (TAE) is to establish the plasma where the ion rotational energy is greater than the ion thermal energy. To verify this, an optical diagnostic was developed to simultaneously measure the Doppler velocity-shift and line-broadening using a 0.75 m, 1800 groves/mm, spectrometer. The output spectrum is magnified and imaged onto a 16-channel photomultiplier tube (PMT) array. The individual PMT outputs are coupled to high-gain, high-frequency, transimpedance amplifiers, providing fast-time response. The Doppler spectroscopy measurements, along with a survey spectrometer and photodiode-light detector, form a suite of diagnostics that provide insights into the time evolution of the plasma-ion distribution and current when accelerated by an azimuthal-electric field.

  10. Commercialization of a 2.5kW Utility Interactive Inverter for Distributed Generation

    SciTech Connect (OSTI)

    Torrey, David A.

    2006-05-26T23:59:59.000Z

    Through this project, Advanced Energy Conversion (AEC) has developed, tested, refined and is preparing to commercialize a 2.5kW utility-interactive inverter system for distributed generation. The inverter technology embodies zero-voltage switching technology that will ultimately yield a system that is smaller, less expensive and more efficient than existing commercial technologies. This program has focused on commercial success through careful synthesis of technology, market-focus and business development. AEC was the primary participant. AEC is utilizing contract manufacturers in the early stages of production, allowing its technical staff to focus on quality control issues and product enhancements. The objective of this project was to bring the AEC inverter technology from its current pre-production state to a commercial product. Federal funds have been used to build and test production-intent inverters, support the implementation of the commercialization plan and bring the product to the point of UL certification.

  11. PV Ramping in a Distributed Generation Environment: A Study Using Solar Measurements; Preprint

    SciTech Connect (OSTI)

    Sengupta, M.; Keller, J.

    2012-06-01T23:59:59.000Z

    Variability in Photovoltaic (PV) generation resulting from variability in the solar radiation over the PV arrays is a topic of continuing concern for those involved with integrating renewables onto existing electrical grids. The island of Lanai, Hawaii is an extreme example of the challenges that integrators will face due to the fact that it is a small standalone grid. One way to study this problem is to take high-resolution solar measurements in multiple locations and model simultaneous PV production for various sizes at those locations. The National Renewable Energy Laboratory (NREL) collected high-resolution solar data at four locations on the island where proposed PV plants will be deployed in the near future. This data set provides unique insight into how the solar radiation may vary between points that are proximal in distance, but diverse in weather, due to the formation of orographic clouds in the center of the island. Using information about each proposed PV plant size, power output was created at high resolution. The team analyzed this output to understand power production ramps at individual locations and the effects of aggregating the production from all four locations. Hawaii is a unique environment, with extremely variable events occurring on a daily basis. This study provided an excellent opportunity for understanding potential worst-case scenarios for PV ramping. This paper provides an introduction to the datasets that NREL collected over a year and a comprehensive analysis of PV variability in a distributed generation scenario.

  12. Diagnostic probes for particle and molecule distributions in laser-generated plumes

    SciTech Connect (OSTI)

    Kimbrell, S.M.

    1990-10-17T23:59:59.000Z

    Laser microprobe analysis (LMA) offers good spatial and depth resolution for solid sampling of virtually any material. Coupled with numerous optical spectroscopic and mass spectrometric detection methods, LMA is a powerful analytical tool. Yet, fundamental understanding of the interaction between the laser and the sample surface leading to the formation of the high temperature plasma (plume) is far from complete. To better understand the process of plume formation, an imaging method based on acousto-optic laser beam deflection has been coupled with light scattering methods and absorption methods to record temporal and spatial maps of the particle and molecule distributions in the plume with good resolution. Because particles can make up a major fraction of the vaporized material under certain operating conditions, they can reflect a large loss of atomic signal for elemental analysis, even when using auxiliary excitation to further vaporized the particles. Characterization of the particle size distributions in plumes should provide insight into the vaporization process and information necessary for studies of efficient particle transfer. Light scattering methods for particle size analysis based on the Mie Theory are used to determine the size of particles in single laser-generated plumes. The methods used, polarization ratio method and dissymmetry ratio method, provide good estimates of particle size with good spatial and temporal resolution for this highly transient system. Large particles, on the order of 0.02-0.2{mu}m in radius, were observed arising directly from the sample surface and from condensation.

  13. Generation of potential/surface density pairs in flat disks Power law distributions

    E-Print Network [OSTI]

    J. -M. Hure; D. Pelat; A. Pierens

    2007-06-25T23:59:59.000Z

    We report a simple method to generate potential/surface density pairs in flat axially symmetric finite size disks. Potential/surface density pairs consist of a ``homogeneous'' pair (a closed form expression) corresponding to a uniform disk, and a ``residual'' pair. This residual component is converted into an infinite series of integrals over the radial extent of the disk. For a certain class of surface density distributions (like power laws of the radius), this series is fully analytical. The extraction of the homogeneous pair is equivalent to a convergence acceleration technique, in a matematical sense. In the case of power law distributions, the convergence rate of the residual series is shown to be cubic inside the source. As a consequence, very accurate potential values are obtained by low order truncation of the series. At zero order, relative errors on potential values do not exceed a few percent typically, and scale with the order N of truncation as 1/N**3. This method is superior to the classical multipole expansion whose very slow convergence is often critical for most practical applications.

  14. Distributed Dynamic State Estimator, Generator Parameter Estimation and Stability Monitoring Demonstration

    SciTech Connect (OSTI)

    Meliopoulos, Sakis; Cokkinides, George; Fardanesh, Bruce; Hedrington, Clinton

    2013-12-31T23:59:59.000Z

    This is the final report for this project that was performed in the period: October1, 2009 to June 30, 2013. In this project, a fully distributed high-fidelity dynamic state estimator (DSE) that continuously tracks the real time dynamic model of a wide area system with update rates better than 60 times per second is achieved. The proposed technology is based on GPS-synchronized measurements but also utilizes data from all available Intelligent Electronic Devices in the system (numerical relays, digital fault recorders, digital meters, etc.). The distributed state estimator provides the real time model of the system not only the voltage phasors. The proposed system provides the infrastructure for a variety of applications and two very important applications (a) a high fidelity generating unit parameters estimation and (b) an energy function based transient stability monitoring of a wide area electric power system with predictive capability. Also the dynamic distributed state estimation results are stored (the storage scheme includes data and coincidental model) enabling an automatic reconstruction and “play back” of a system wide disturbance. This approach enables complete play back capability with fidelity equal to that of real time with the advantage of “playing back” at a user selected speed. The proposed technologies were developed and tested in the lab during the first 18 months of the project and then demonstrated on two actual systems, the USVI Water and Power Administration system and the New York Power Authority’s Blenheim-Gilboa pumped hydro plant in the last 18 months of the project. The four main thrusts of this project, mentioned above, are extremely important to the industry. The DSE with the achieved update rates (more than 60 times per second) provides a superior solution to the “grid visibility” question. The generator parameter identification method fills an important and practical need of the industry. The “energy function” based transient stability monitoring opens up new ways to protect the power grid, better manage disturbances, confine their impact and in general improve the reliability and security of the system. Finally, as a by-product of the proposed research project, the developed system is able to “play back” disturbances by a click of a mouse. The importance of this by-product is evident by considering the tremendous effort exerted after the August 2003 blackout to piece together all the disturbance recordings, align them and recreate the sequence of events. This project has moved the state of art from fault recording by individual devices to system wide disturbance recording with “play back” capability.

  15. Coordinating Automated Vehicles via Communication

    E-Print Network [OSTI]

    Bana, Soheila Vahdati

    2001-01-01T23:59:59.000Z

    1.1 Vehicle Automation . . . . . . . . . . . 1.1.1 Controlareas of technology in vehicle automation and communicationChapter 1 Introduction Vehicle Automation Automation is an

  16. Index for the Evaluation of Distributed Generation Impacts on Distribution System Luis F. Ochoa (1,2)

    E-Print Network [OSTI]

    Harrison, Gareth

    decisions that lead to the best management of the system, regarding both technical and economical aspects. Various studies have demonstrated that integration of DG in distribution networks may create technical in voltage control processes, diminish or increase losses, etc. In fact, all our knowledge about distribution

  17. Integrated Simulation Development and Decision Support Tool-Set for Utility Market and Distributed Solar Power Generation

    SciTech Connect (OSTI)

    Daye, Tony [Green Power Labs

    2013-09-30T23:59:59.000Z

    This project will enable utilities to develop long-term strategic plans that integrate high levels of renewable energy generation, and to better plan power system operations under high renewable penetration. The program developed forecast data streams for decision support and effective integration of centralized and distributed solar power generation in utility operations. This toolset focused on real time simulation of distributed power generation within utility grids with the emphasis on potential applications in day ahead (market) and real time (reliability) utility operations. The project team developed and demonstrated methodologies for quantifying the impact of distributed solar generation on core utility operations, identified protocols for internal data communication requirements, and worked with utility personnel to adapt the new distributed generation (DG) forecasts seamlessly within existing Load and Generation procedures through a sophisticated DMS. This project supported the objectives of the SunShot Initiative and SUNRISE by enabling core utility operations to enhance their simulation capability to analyze and prepare for the impacts of high penetrations of solar on the power grid. The impact of high penetration solar PV on utility operations is not only limited to control centers, but across many core operations. Benefits of an enhanced DMS using state-of-the-art solar forecast data were demonstrated within this project and have had an immediate direct operational cost savings for Energy Marketing for Day Ahead generation commitments, Real Time Operations, Load Forecasting (at an aggregate system level for Day Ahead), Demand Response, Long term Planning (asset management), Distribution Operations, and core ancillary services as required for balancing and reliability. This provided power system operators with the necessary tools and processes to operate the grid in a reliable manner under high renewable penetration.

  18. Distributed Generation Potential of the U.S. CommercialSector

    SciTech Connect (OSTI)

    LaCommare, Kristina Hamachi; Edwards, Jennifer L.; Gumerman,Etan; Marnay, Chris

    2005-06-01T23:59:59.000Z

    Small-scale (100 kW-5 MW) on-site distributed generation (DG) economically driven by combined heat and power (CHP) applications and, in some cases, reliability concerns will likely emerge as a common feature of commercial building energy systems in developed countries over the next two decades. In the U.S., private and public expectations for this technology are heavily influenced by forecasts published by the Energy Information Administration (EIA), most notably the Annual Energy Outlook (AEO). EIA's forecasts are typically made using the National Energy Modeling System (NEMS), which has a forecasting module that predicts the penetration of several possible commercial building DG technologies over the period 2005-2025. Annual penetration is forecast by estimating the payback period for each technology, for each of a limited number of representative building types, for each of nine regions. This process results in an AEO2004 forecast deployment of about a total 3 GW of DG electrical generating capacity by 2025, which is only 0.25 percent of total forecast U.S. capacity. Analyses conducted using both the AEO2003 and AEO2004 versions of NEMS changes the baseline costs and performance characteristics of DG to reflect a world without U.S. Department of Energy (DOE) research into several thermal DG technologies, which is then compared to a case with enhanced technology representative of the successful achievement of DOE research goals. The net difference in 2025 DG penetration is dramatic using the AEO2003 version of NEMS, but much smaller in the AEO2004 version. The significance and validity of these contradictory results are discussed, and possibilities for improving estimates of commercial U.S. DG potential are explored.

  19. A Multi-State Model for the Reliability Assessment of a Distributed Generation System via Universal Generating Function

    E-Print Network [OSTI]

    Boyer, Edmond

    , Milan, Italy, Dipartimento di Energia Enrico.zio@polimi.it Abstract The current and future developments renewable technology (e.g. wind or solar, etc.) whose behavior is described by a binary state, working assessment, multi-state modeling, universal generating function #12;2 Notations Solar irradiance Total number

  20. FEMTOSECOND TIMING DISTRIBUTION AND CONTROL FOR NEXT GENERATION ACCELERATORS AND LIGHT SOURCES

    SciTech Connect (OSTI)

    Chen, Li-Jin [Idesta Quantum Electronics, LLC

    2014-03-31T23:59:59.000Z

    Femtosecond Timing Distribution At LCLS Free-electron-lasers (FEL) have the capability of producing high photon flux from the IR to the hard x-ray wavelength range and to emit femtosecond and eventually even at-tosecond pulses. This makes them an ideal tool for fundamental as well as applied re-search. Timing precision at the Stanford Linear Coherent Light Source (LCLS) between the x-ray FEL (XFEL) and ultrafast optical lasers is currently no better than 100 fs RMS. Ideally this precision should be much better and could be limited only by the x-ray pulse duration, which can be as short as a few femtoseconds. An increasing variety of science problems involving electron and nuclear dynamics in chemical and material systems will become accessible as the timing improves to a few femtoseconds. Advanced methods of electron beam conditioning or pulse injection could allow the FEL to achieve pulse durations less than one femtosecond. The objec-tive of the work described in this proposal is to set up an optical timing distribution sys-tem based on modelocked Erbium doped fiber lasers at LCLS facility to improve the timing precision in the facility and allow time stamping with a 10 fs precision. The primary commercial applications for optical timing distributions systems are seen in the worldwide accelerator facilities and next generation light sources community. It is reasonable to expect that at least three major XFELs will be built in the next decade. In addition there will be up to 10 smaller machines, such as FERMI in Italy and Maxlab in Sweden, plus the market for upgrading already existing facilities like Jefferson Lab. The total market is estimated to be on the order of a 100 Million US Dollars. The company owns the exclusive rights to the IP covering the technology enabling sub-10 fs synchronization systems. Testing this technology, which has set records in a lab environment, at LCLS, hence in a real world scenario, is an important corner stone of bringing the technology to market.

  1. Home Network Technologies and Automating Demand Response

    SciTech Connect (OSTI)

    McParland, Charles

    2009-12-01T23:59:59.000Z

    Over the past several years, interest in large-scale control of peak energy demand and total consumption has increased. While motivated by a number of factors, this interest has primarily been spurred on the demand side by the increasing cost of energy and, on the supply side by the limited ability of utilities to build sufficient electricity generation capacity to meet unrestrained future demand. To address peak electricity use Demand Response (DR) systems are being proposed to motivate reductions in electricity use through the use of price incentives. DR systems are also be design to shift or curtail energy demand at critical times when the generation, transmission, and distribution systems (i.e. the 'grid') are threatened with instabilities. To be effectively deployed on a large-scale, these proposed DR systems need to be automated. Automation will require robust and efficient data communications infrastructures across geographically dispersed markets. The present availability of widespread Internet connectivity and inexpensive, reliable computing hardware combined with the growing confidence in the capabilities of distributed, application-level communications protocols suggests that now is the time for designing and deploying practical systems. Centralized computer systems that are capable of providing continuous signals to automate customers reduction of power demand, are known as Demand Response Automation Servers (DRAS). The deployment of prototype DRAS systems has already begun - with most initial deployments targeting large commercial and industrial (C & I) customers. An examination of the current overall energy consumption by economic sector shows that the C & I market is responsible for roughly half of all energy consumption in the US. On a per customer basis, large C & I customers clearly have the most to offer - and to gain - by participating in DR programs to reduce peak demand. And, by concentrating on a small number of relatively sophisticated energy consumers, it has been possible to improve the DR 'state of the art' with a manageable commitment of technical resources on both the utility and consumer side. Although numerous C & I DR applications of a DRAS infrastructure are still in either prototype or early production phases, these early attempts at automating DR have been notably successful for both utilities and C & I customers. Several factors have strongly contributed to this success and will be discussed below. These successes have motivated utilities and regulators to look closely at how DR programs can be expanded to encompass the remaining (roughly) half of the state's energy load - the light commercial and, in numerical terms, the more important residential customer market. This survey examines technical issues facing the implementation of automated DR in the residential environment. In particular, we will look at the potential role of home automation networks in implementing wide-scale DR systems that communicate directly to individual residences.

  2. A framework for automated PDE-constrained optimisation

    E-Print Network [OSTI]

    S. W. Funke

    2013-03-01T23:59:59.000Z

    Mar 1, 2013 ... Its main features are an intuitive mathematical interface, a high degree of automation, and an efficient implementation of the generated adjoint ...

  3. automated eddy current: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    model-assisted POD study. Keywords 2 AUTOMATED ANALYSIS OF EDDY CURRENT SIGNALS IN STEAM GENERATOR TUBE INSPECTION CiteSeer Summary: Abstract: Accurate and consistent...

  4. Retrospective modeling of the merit-order effect on wholesale electricity prices from distributed photovoltaic generation in the

    E-Print Network [OSTI]

    Sandiford, Mike

    Retrospective modeling of the merit-order effect on wholesale electricity prices from distributed, the depression in wholesale prices has significant value. c 5 GW of solar generation would have saved $1.8 billion in the market over two years. c The depression of wholesale prices offsets the cost of support

  5. PhotoVoltaic distributed generation for Lanai power grid real-time simulation and control integration scenario.

    SciTech Connect (OSTI)

    Robinett, Rush D., III; Kukolich, Keith (Opal RT Technologies, Montreal, Quebec, Canada); Wilson, David Gerald; Schenkman, Benjamin L.

    2010-06-01T23:59:59.000Z

    This paper discusses the modeling, analysis, and testing in a real-time simulation environment of the Lanai power grid system for the integration and control of PhotoVoltaic (PV) distributed generation. The Lanai Island in Hawaii is part of the Hawaii Clean Energy Initiative (HCEI) to transition to 30% renewable green energy penetration by 2030. In Lanai the primary loads come from two Castle and Cook Resorts, in addition to residential needs. The total peak load profile is 12470 V, 5.5 MW. Currently there are several diesel generators that meet these loading requirements. As part of the HCEI, Lanai has initially installed 1.2 MW of PV generation. The goal of this study has been to evaluate the impact of the PV with respect to the conventional carbon-based diesel generation in real time simulation. For intermittent PV distributed generation, the overall stability and transient responses are investigated. A simple Lanai 'like' model has been developed in the Matlab/Simulink environment (see Fig. 1) and to accommodate real-time simulation of the hybrid power grid system the Opal-RT Technologies RT-Lab environment is used. The diesel generators have been modelled using the SimPowerSystems toolbox swing equations and a custom Simulink module has been developed for the High level PV generation. All of the loads have been characterized primarily as distribution lines with series resistive load banks with one VAR load bank. Three-phase faults are implemented for each bus. Both conventional and advanced control architectures will be used to evaluate the integration of the PV onto the current power grid system. The baseline numerical results include the stable performance of the power grid during varying cloud cover (PV generation ramping up/down) scenarios. The importance of assessing the real-time scenario is included.

  6. Proposal for the award of a contract for the supply and maintenance of six 380 V 50 Hz diesel generators for the LEP electrical distribution system

    E-Print Network [OSTI]

    1986-01-01T23:59:59.000Z

    Proposal for the award of a contract for the supply and maintenance of six 380 V 50 Hz diesel generators for the LEP electrical distribution system

  7. Methods for Multisweep Automation

    SciTech Connect (OSTI)

    SHEPHERD,JASON F.; MITCHELL,SCOTT A.; KNUPP,PATRICK; WHITE,DAVID R.

    2000-09-14T23:59:59.000Z

    Sweeping has become the workhorse algorithm for creating conforming hexahedral meshes of complex models. This paper describes progress on the automatic, robust generation of MultiSwept meshes in CUBIT. MultiSweeping extends the class of volumes that may be swept to include those with multiple source and multiple target surfaces. While not yet perfect, CUBIT's MultiSweeping has recently become more reliable, and been extended to assemblies of volumes. Sweep Forging automates the process of making a volume (multi) sweepable: Sweep Verification takes the given source and target surfaces, and automatically classifies curve and vertex types so that sweep layers are well formed and progress from sources to targets.

  8. Modeling and Generating Daily Changes in Market Variables Using A Multivariate Mixture of Normal Distributions

    E-Print Network [OSTI]

    Wang, Jin

    Distributions Jin Wang Department of Mathematics and Computer Science Valdosta State University Valdosta, GA 31698-0040 January 28, 2000 Abstract The mixture of normal distributions provides a useful extension of the normal distribution for modeling of daily changes in market variables with fatter-than-normal tails

  9. Rate of convergence of the short cycle distribution in random regular graphs generated by pegging

    E-Print Network [OSTI]

    Wormald, Nick

    of the random network (degree distribution, connectivity, diameter, etc.) vary when p is assigned different values. However, the Erdos-R´enyi model cannot produce scale-free networks [2], whose degree distribution, the stationary distribution is uniform. Thus, for this simplified version of the SWAN network, the limiting

  10. THE GALACTIC SPATIAL DISTRIBUTION OF OB ASSOCIATIONS AND THEIR SURROUNDING SUPERNOVA-GENERATED SUPERBUBBLES

    SciTech Connect (OSTI)

    Higdon, J. C. [W. M. Keck Science Center, Claremont Colleges, Claremont, CA 91711-5916 (United States); Lingenfelter, R. E., E-mail: jhigdon@kecksci.claremont.edu, E-mail: rlingenfelter@ucsd.edu [Center for Astrophysics and Space Sciences, University of California San Diego, La Jolla, CA 92093 (United States)

    2013-10-01T23:59:59.000Z

    The Galactic spatial distribution of OB associations and their surrounding superbubbles (SBs) reflect the distribution of a wide range of important processes in our Galaxy. In particular, it can provide a three-dimensional measure not only of the major source distribution of Galactic cosmic rays, but also the Galactic star formation distribution, the Lyman continuum ionizing radiation distribution, the core-collapse supernova distribution, the neutron star and stellar black hole production distribution, and the principal source distribution of freshly synthesized elements. Thus, we construct a three-dimensional spatial model of the massive-star distribution based primarily on the emission of the H II envelopes that surround the giant SBs and are maintained by the ionizing radiation of the embedded O stars. The Galactic longitudinal distribution of the 205 ?m N II radiation, emitted by these H II envelopes, is used to infer the spatial distribution of SBs. We find that the Galactic SB distribution is dominated by the contribution of massive-star clusters residing in the spiral arms.

  11. Test Automation with TTCN-3 -State of the Art and a Future Perspective

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Test Automation with TTCN-3 - State of the Art and a Future Perspective Ina Schieferdecker TU.schieferdecker@fokus.fraunhofer.de Abstract. Test automation encompasses all activities to automate various steps in the overall testing process including automation of test management, test generation, or test execution. The standardized

  12. Distributed Generation versus Centralised Supply: a Social Cost-Benefit Analysis

    E-Print Network [OSTI]

    Gulli, Francesco

    2004-06-16T23:59:59.000Z

    Generation versus Centralised Supply: a Social Cost-Benefit Analysis Francesco Gullì* Istituto di Economia e Politica dell’Energia e dell’Ambiente (Iefe). Università Bocconi, Milano July 2003 1. Introduction #1; The restructuring and privatisation...

  13. Updated greenhouse gas and criteria air pollutant emission factors and their probability distribution functions for electricity generating units

    SciTech Connect (OSTI)

    Cai, H.; Wang, M.; Elgowainy, A.; Han, J. (Energy Systems)

    2012-07-06T23:59:59.000Z

    Greenhouse gas (CO{sub 2}, CH{sub 4} and N{sub 2}O, hereinafter GHG) and criteria air pollutant (CO, NO{sub x}, VOC, PM{sub 10}, PM{sub 2.5} and SO{sub x}, hereinafter CAP) emission factors for various types of power plants burning various fuels with different technologies are important upstream parameters for estimating life-cycle emissions associated with alternative vehicle/fuel systems in the transportation sector, especially electric vehicles. The emission factors are typically expressed in grams of GHG or CAP per kWh of electricity generated by a specific power generation technology. This document describes our approach for updating and expanding GHG and CAP emission factors in the GREET (Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation) model developed at Argonne National Laboratory (see Wang 1999 and the GREET website at http://greet.es.anl.gov/main) for various power generation technologies. These GHG and CAP emissions are used to estimate the impact of electricity use by stationary and transportation applications on their fuel-cycle emissions. The electricity generation mixes and the fuel shares attributable to various combustion technologies at the national, regional and state levels are also updated in this document. The energy conversion efficiencies of electric generating units (EGUs) by fuel type and combustion technology are calculated on the basis of the lower heating values of each fuel, to be consistent with the basis used in GREET for transportation fuels. On the basis of the updated GHG and CAP emission factors and energy efficiencies of EGUs, the probability distribution functions (PDFs), which are functions that describe the relative likelihood for the emission factors and energy efficiencies as random variables to take on a given value by the integral of their own probability distributions, are updated using best-fit statistical curves to characterize the uncertainties associated with GHG and CAP emissions in life-cycle modeling with GREET.

  14. Utilizing Electric Vehicles to Assist Integration of Large Penetrations of Distributed Photovoltaic Generation Capacity

    SciTech Connect (OSTI)

    Tuffner, Francis K.; Chassin, Forrest S.; Kintner-Meyer, Michael CW; Gowri, Krishnan

    2012-11-30T23:59:59.000Z

    Executive Summary Introduction and Motivation This analysis provides the first insights into the leveraging potential of distributed photovoltaic (PV) technologies on rooftop and electric vehicle (EV) charging. Either of the two technologies by themselves - at some high penetrations – may cause some voltage control challenges or overloading problems, respectively. But when combined, there – at least intuitively – could be synergistic effects, whereby one technology mitigates the negative impacts of the other. High penetration of EV charging may overload existing distribution system components, most prominently the secondary transformer. If PV technology is installed at residential premises or anywhere downstream of the secondary transformer, it will provide another electricity source thus, relieving the loading on the transformers. Another synergetic or mitigating effect could be envisioned when high PV penetration reverts the power flow upward in the distribution system (from the homes upstream into the distribution system). Protection schemes may then no longer work and voltage violation (exceeding the voltage upper limited of the ANSI voltage range) may occur. In this particular situation, EV charging could absorb the electricity from the PV, such that the reversal of power flow can be reduced or alleviated. Given these potential mutual synergistic behaviors of PV and EV technologies, this project attempted to quantify the benefits of combining the two technologies. Furthermore, of interest was how advanced EV control strategies may influence the outcome of the synergy between EV charging and distributed PV installations. Particularly, Californian utility companies with high penetration of the distributed PV technology, who have experienced voltage control problems, are interested how intelligent EV charging could support or affect the voltage control

  15. Investigation of anti-islanding schemes for utility interconnection of distributed fuel cell powered generations

    E-Print Network [OSTI]

    Jeraputra, Chuttchaval

    2006-04-12T23:59:59.000Z

    perspectives, some of the apparent advantages include distribution and transmission capacity relief, load peak shaving, deferral of high cost transmission and distribution (T&D) system upgrades, etc. Utility customers also gain benefits from efficient use... power variation ? P and load real power PLoad (see (1.5)) as, 1 LoadP PV ?? (1.8) From (1.8), the real power variation ? P must be set at least ? 0.20 (per-unit) so that a change in the voltage at inverter (DFPG) terminal is out of the threshold (0...

  16. A Study of Distributed Generation System Characteristics and Protective Load Control Strategy

    E-Print Network [OSTI]

    Chen, Zhe

    different type of WTs are integrated into a DGS, the DGS presents different properties. Therefore Turbines (WT) have attracted significant attentions. A DGS with renewable sources such as WTs and solar panels is distinct from a conventional power system. The renewable generation units make a DGS

  17. Practical stability assessment of distributed synchronous generators under variations in the system equilibrium conditions

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    synchro- nous generators driven by steam turbines have been connected to the system using a byproduct of Brazil, this sector of the national industry had already considerable experience in the usage of steam turbines, which have been extensively employed within its internal production [1­3]. As a result, several

  18. Subsystem Interaction Analysis in Power Distribution Systems of Next Generation Airlifters

    E-Print Network [OSTI]

    Lindner, Douglas K.

    . Quan Keenan of Lockheed Martin Control Systems, Johnson City, New York, in providing the models control actuator systems. The aircraft power distribution system plays a central role in the development tolerant, autonomously controlled electrical power system to deliver high quality power from the sources

  19. Impact of Renewable Distributed Generation on Power Systems M. Begovi, A. Pregelj, A. Rohatgi D. Novosel

    E-Print Network [OSTI]

    , improve the voltage profile across the feeder, may reduce the loading level of branches and substation the effect of DG penetration on the actual load demand and voltage profile of the distribution feeder. However, DG systems inherently provide some benefits to the utility. They may level the load curve

  20. Unnatural landscapes in ecology: Generating the spatial distribution of brine spills

    SciTech Connect (OSTI)

    Jager, Yetta [ORNL; Efroymson, Rebecca Ann [ORNL; Sublette, K. [University of Tulsa; Ashwood, Tom L [ORNL

    2005-01-01T23:59:59.000Z

    Quantitative tools are needed to evaluate the ecological effects of increasing petroleum production. In this article, we describe two stochastic models for simulating the spatial distribution of brine spills on a landscape. One model uses general assumptions about the spatial arrangement of spills and their sizes; the second model distributes spills by siting rectangular well complexes and conditioning spill probabilities on the configuration of pipes. We present maps of landscapes with spills produced by the two methods and compare the ability of the models to reproduce a specified spill area. A strength of the models presented here is their ability to extrapolate from the existing landscape to simulate landscapes with a higher (or lower) density of oil wells.

  1. Advanced Inverter Technology for High Penetration Levels of PV Generation in Distribution Systems

    SciTech Connect (OSTI)

    Schauder, C.

    2014-03-01T23:59:59.000Z

    This subcontract report was completed under the auspices of the NREL/SCE High-Penetration Photovoltaic (PV) Integration Project, which is co-funded by the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) and the California Solar Initiative (CSI) Research, Development, Demonstration, and Deployment (RD&D) program funded by the California Public Utility Commission (CPUC) and managed by Itron. This project is focused on modeling, quantifying, and mitigating the impacts of large utility-scale PV systems (generally 1-5 MW in size) that are interconnected to the distribution system. This report discusses the concerns utilities have when interconnecting large PV systems that interconnect using PV inverters (a specific application of frequency converters). Additionally, a number of capabilities of PV inverters are described that could be implemented to mitigate the distribution system-level impacts of high-penetration PV integration. Finally, the main issues that need to be addressed to ease the interconnection of large PV systems to the distribution system are presented.

  2. Multiplex automated genome engineering

    DOE Patents [OSTI]

    Church, George M; Wang, Harris H; Isaacs, Farren J

    2013-10-29T23:59:59.000Z

    The present invention relates to automated methods of introducing multiple nucleic acid sequences into one or more target cells.

  3. Charmaine Toy Automation Engineer,

    E-Print Network [OSTI]

    Horowitz, Roberto

    @me.berkeley.edu Nonstationary Velocity Profiles for Emergency Vehicles on Automated Highways This paper explores the notion and usefulness of nonstationary velocity profiles for high priority emergency vehicle transit on automatedCharmaine Toy Automation Engineer, DiCon Fiberoptics, Inc., Richmond, CA 94804 e-mail: charm

  4. Developing and Implementing the Foundation for a Renewable Energy-Based "Distribution Generation Micro-grid": A California Energy Commission Public Interest Energy Research Co-Funded Program 

    E-Print Network [OSTI]

    Lilly, P.; Sebold, F. D.; Carpenter, M.; Kitto, W.

    2002-01-01T23:59:59.000Z

    The California Energy Commission has been implementing its Public Interest Energy Research (PIER) and Renewable Energy Programs since early 1998. In the last two years, the demand for renewable distributed generation systems has increased rapidly...

  5. Abstract-Distributed energy resources (DER) are quickly making their way to industry primarily as backup generation.

    E-Print Network [OSTI]

    Tolbert, Leon M.

    generation includes microturbine generators, internal combustion engines (ICEs), and fuel cells. Frequently

  6. Joint Genome Institute's Automation Approach and History

    E-Print Network [OSTI]

    Roberts, Simon

    2006-01-01T23:59:59.000Z

    Joint Genome Institute’s Automation Approach and Historythroughput environment; – automation does not necessarilyissues “Islands of Automation” – modular instruments with

  7. Magnetic field distribution in the plasma flow generated by a plasma focus discharge

    SciTech Connect (OSTI)

    Mitrofanov, K. N., E-mail: mitrofan@triniti.ru [Troitsk Institute for Innovaiton and Fusion Research (Russian Federation); Krauz, V. I., E-mail: krauz_vi@nrcki.ru; Myalton, V. V.; Velikhov, E. P.; Vinogradov, V. P.; Vinogradova, Yu. V. [National Research Centre Kurchatov Institute (Russian Federation)

    2014-11-15T23:59:59.000Z

    The magnetic field in the plasma jet propagating from the plasma pinch region along the axis of the chamber in a megajoule PF-3 plasma focus facility is studied. The dynamics of plasma with a trapped magnetic flow is analyzed. The spatial sizes of the plasma jet region in which the magnetic field concentrates are determined in the radial and axial directions. The magnetic field configuration in the plasma jet is investigated: the radial distribution of the azimuthal component of the magnetic field inside the jet is determined. It is shown that the magnetic induction vector at a given point in space can change its direction during the plasma flight. Conclusions regarding the symmetry of the plasma flow propagation relative to the chamber axis are drawn.

  8. Sensors and Automated Analyzers for Radionuclides

    SciTech Connect (OSTI)

    Grate, Jay W.; Egorov, Oleg B.

    2003-03-27T23:59:59.000Z

    The production of nuclear weapons materials has generated large quantities of nuclear waste and significant environmental contamination. We have developed new, rapid, automated methods for determination of radionuclides using sequential injection methodologies to automate extraction chromatographic separations, with on-line flow-through scintillation counting for real time detection. This work has progressed in two main areas: radionuclide sensors for water monitoring and automated radiochemical analyzers for monitoring nuclear waste processing operations. Radionuclide sensors have been developed that collect and concentrate radionuclides in preconcentrating minicolumns with dual functionality: chemical selectivity for radionuclide capture and scintillation for signal output. These sensors can detect pertechnetate to below regulatory levels and have been engineered into a prototype for field testing. A fully automated process monitor has been developed for total technetium in nuclear waste streams. This instrument performs sample acidification, speciation adjustment, separation and detection in fifteen minutes or less.

  9. An Automation System for Optimizing a Supply Chain Network Design under the Influence of Demand Uncertainty

    E-Print Network [OSTI]

    Polany, Rany

    2012-01-01T23:59:59.000Z

    Automation . . . . . . . . . . . . . . . . . . . . . . iii 3Automation . . . . . . . . . . . . . . . . . . . . . . 5Dashboard/Cockpit Automation . . . . . . . . . . . . .

  10. Automation without predictability is a recipe for failure Raja R. Sambasivan & Gregory R. Ganger

    E-Print Network [OSTI]

    Automation without predictability is a recipe for failure Raja R. Sambasivan & Gregory R. Ganger-3890 Abstract Automated management seems a must, as distributed systems and datacenters continue to grow in scale and complexity. But, automation of performance problem diagnosis and tuning relies upon

  11. Development and Testing of a 6-Cylinder HCCI Engine for Distributed Generation

    SciTech Connect (OSTI)

    Flowers, D L; Martinez-Frias, J; Espinosa-Loza, F; Killingsworth, N; Aceves, S M; Dibble, R; Kristic, M; Bining, A

    2005-07-12T23:59:59.000Z

    This paper describes the technical approach for converting a Caterpillar 3406 natural gas spark ignited engine into HCCI mode. The paper describes all stages of the process, starting with a preliminary analysis that determined that the engine can be operated by preheating the intake air with a heat exchanger that recovers energy from the exhaust gases. This heat exchanger plays a dual role, since it is also used for starting the engine. For start-up, the heat exchanger is preheated with a natural gas burner. The engine is therefore started in HCCI mode, avoiding the need to handle the potentially difficult transition from SI or diesel mode to HCCI. The fueling system was modified by replacing the natural gas carburetor with a liquid petroleum gas (LPG) carburetor. This modification sets an upper limit for the equivalence ratio at {phi} {approx} 0.4, which is ideal for HCCI operation and guarantees that the engine will not fail due to knock. Equivalence ratio can be reduced below 0.4 for low load operation with an electronic control valve. Intake boosting has been a challenge, as commercially available turbochargers are not a good match for the engine, due to the low HCCI exhaust temperature. Commercial introduction of HCCI engines for stationary power will therefore require the development of turbochargers designed specifically for this mode of operation. Considering that no appropriate off-the-shelf turbocharger for HCCI engines exists at this time, we are investigating mechanical supercharging options, which will deliver the required boost pressure (3 bar absolute intake) at the expense of some reduction in the output power and efficiency. An appropriate turbocharger can later be installed for improved performance when it becomes available or when a custom turbocharger is developed. The engine is now running in HCCI mode and producing power in an essentially naturally aspirated mode. Current work focuses on developing an automatic controller for obtaining consistent combustion in the 6 cylinders. The engine will then be tested for 1000 hours to demonstrate durability. This paper presents intermediate progress towards development of an HCCI engine for stationary power generation and next steps towards achieving the project goals.

  12. DISTRIBUTION COEFICIENTS (KD) GENERATED FROM A CORE SAMPLE COLLECTED FROM THE SALTSTONE DISPOSAL FACILITY

    SciTech Connect (OSTI)

    Almond, P.; Kaplan, D.

    2011-04-25T23:59:59.000Z

    Core samples originating from Vault 4, Cell E of the Saltstone Disposal Facility (SDF) were collected in September of 2008 (Hansen and Crawford 2009, Smith 2008) and sent to SRNL to measure chemical and physical properties of the material including visual uniformity, mineralogy, microstructure, density, porosity, distribution coefficients (K{sub d}), and chemical composition. Some data from these experiments have been reported (Cozzi and Duncan 2010). In this study, leaching experiments were conducted with a single core sample under conditions that are representative of saltstone performance. In separate experiments, reducing and oxidizing environments were targeted to obtain solubility and Kd values from the measurable species identified in the solid and aqueous leachate. This study was designed to provide insight into how readily species immobilized in saltstone will leach from the saltstone under oxidizing conditions simulating the edge of a saltstone monolith and under reducing conditions, targeting conditions within the saltstone monolith. Core samples were taken from saltstone poured in December of 2007 giving a cure time of nine months in the cell and a total of thirty months before leaching experiments began in June 2010. The saltstone from Vault 4, Cell E is comprised of blast furnace slag, class F fly ash, portland cement, and Deliquification, Dissolution, and Adjustment (DDA) Batch 2 salt solution. The salt solution was previously analyzed from a sample of Tank 50 salt solution and characterized in the 4QCY07 Waste Acceptance Criteria (WAC) report (Zeigler and Bibler 2009). Subsequent to Tank 50 analysis, additional solution was added to the tank solution from the Effluent Treatment Project as well as from inleakage from Tank 50 pump bearings (Cozzi and Duncan 2010). Core samples were taken from three locations and at three depths at each location using a two-inch diameter concrete coring bit (1-1, 1-2, 1-3; 2-1, 2-2, 2-3; 3-1, 3-2, 3-3) (Hansen and Crawford 2009). Leaching experiments were conducted with a section of core sample 3-2. All cores from location 3 were drilled without using water. Core sample 3-2 was drilled from approximately six inches to a depth of approximately 13 inches. Approximately six inches of the core was removed but it broke into two pieces during removal from the bit. At the time of drilling, core material appeared olive green in color (Smith 2008). The fact that the samples were cored as olive green and were received after storage with a gray outer layer is indicative that some oxidation had occurred prior to leaching studies.

  13. Architectures of Test Automation 1 High Volume Test AutomationHigh Volume Test Automation

    E-Print Network [OSTI]

    Architectures of Test Automation 1 High Volume Test AutomationHigh Volume Test Automation Cem Kaner Institute of Technology October 2003 #12;Architectures of Test Automation 2 Acknowledgements developed a course on test automation architecture, and in the Los Altos Workshops on Software Testing

  14. Copyright (c) Cem Kaner, Automated Testing. 1 Software Test Automation:Software Test Automation

    E-Print Network [OSTI]

    Copyright (c) Cem Kaner, Automated Testing. 1 Software Test Automation:Software Test Automation: A RealA Real--World ProblemWorld Problem Cem Kaner, Ph.D., J.D. #12;Copyright (c) Cem Kaner, Automated Testing. 2 This TalkThis Talk The most widely used class of automated testing tools leads senior software

  15. High Volume Test Automation 1 High Volume Test AutomationHigh Volume Test Automation

    E-Print Network [OSTI]

    High Volume Test Automation 1 High Volume Test AutomationHigh Volume Test Automation Keynote Automation 2 AcknowledgementsAcknowledgements · Many of the ideas in this presentation were initially jointly developed with Doug Hoffman,as we developed a course on test automation architecture, and in the Los Altos

  16. Rnnotator: an automated de novo transcriptome assembly pipeline from stranded RNA-Seq reads

    E-Print Network [OSTI]

    Martin, Jeffrey

    2011-01-01T23:59:59.000Z

    transcriptome assembly pipeline from stranded RNA-Seq readsRnnotator assembly pipeline. Figure 2. Read dereplicationan automated software pipeline that generates transcript

  17. Design, Simulation, and Analysis of Substation Automation Networks

    E-Print Network [OSTI]

    Kembanur Natarajan, Elangovan

    2012-07-16T23:59:59.000Z

    on the Substation Automation Systems (SAS). Substations are nodes in the smart grid infrastructure that help the in transportation of power by connecting the transmission and distribution lines. The SAS applications are con figured to operate with minimal human...

  18. An Optimization-Based Framework for Automated Market-Making

    E-Print Network [OSTI]

    Chen, Yiling

    An Optimization-Based Framework for Automated Market-Making Jacob Abernethy EECS Department UC that copies are not made or distributed for profit or commercial advantage and that copies bear this notice

  19. A Verified Hybrid Controller For Automated Vehicles

    E-Print Network [OSTI]

    Lygeros, J.; Godbole, D. N.; Sastry, S.

    1997-01-01T23:59:59.000Z

    con- trollers for vehicle automation," in American ControlTomizuka, Vehicle lateral control for highway automation,"

  20. Apparatus for automated testing of biological specimens

    DOE Patents [OSTI]

    Layne, Scott P. (Los Angeles, CA); Beugelsdijk, Tony J. (Los Alamos, NM)

    1999-01-01T23:59:59.000Z

    An apparatus for performing automated testing of infections biological specimens is disclosed. The apparatus comprise a process controller for translating user commands into test instrument suite commands, and a test instrument suite comprising a means to treat the specimen to manifest an observable result, and a detector for measuring the observable result to generate specimen test results.

  1. Distributed Generation Standard Contracts

    Broader source: Energy.gov [DOE]

    '''''Note: The second enrollment period for standard contracts in 2013 closed June 28. The third is scheduled to begin in September.'''''

  2. Cognitive Engineering Automation and Human

    E-Print Network [OSTI]

    Parasuraman, Raja

    · Home automation · Robotics · Unmanned vehicles (UAVs and UGVs) · Drug design/Molecular geneticsCognitive Engineering PSYC 530 Automation and Human Performance Raja Parasuraman #12;Overview Automation-Related Accidents Levels and Stages of Automation Information Acquisition and Analysis Decision

  3. RF test bench automation Description

    E-Print Network [OSTI]

    Dobigeon, Nicolas

    RF test bench automation Description: Callisto would like to implement automated RF test bench. Three RF test benches have to be studied and automated: LNA noise temperature test bench LNA gain phase of the test benches and an implementation of the automation phase. Tasks: Noise temperature

  4. Architecting Specifications for Automated Test Case Generation

    E-Print Network [OSTI]

    Sinnott, R.O.

    Sinnott,R.O. Proceedings of International Conference on Software Engineering and Formal Methods, September 2003, Brisbane Australia pp 24-34 IEEE Computer Society Press

  5. Comparison of two types of 60 GHz photonic millimeter-wave generation and distribution of a 3 Gb/s OFDM signal

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    converts the optical signal into an electrical one. After, the signal is sent into a low noise amplifier a new generation of optoelec- tronic components designed for 60 GHz applications. I. RADIO OVER FIBRE and distribution of a 3 Gb/s OFDM signal. The first one uses low cost well known components and the second one

  6. Abstract--Application of individual distributed generators can cause as many problems as it may solve. A better way to

    E-Print Network [OSTI]

    , microturbines, photovoltaic, fuel cells and wind- power. Most emerging technologies such as micro-turbines, photovoltaic, fuel cells and gas internal combustion engines with permanent magnet generator require generation technologies permits generators to be placed optimally in relation to heat loads allowing for use

  7. Development of Building Automation and Control Systems

    E-Print Network [OSTI]

    Yang, Yang; Zhu, Qi; Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

    2012-01-01T23:59:59.000Z

    A design flow for building automation and control systems,’’Development of Building Automation and Control Systems Yangdesign of the build- ing automation system (including the

  8. Demonstration of Automated Heavy-Duty Vehicles

    E-Print Network [OSTI]

    2006-01-01T23:59:59.000Z

    a future in which vehicle automation technologies are ableto support the heavy vehicle automation including PrecisionCommittee on Vehicle-Highway Automation, and the attendees

  9. Development of Building Automation and Control Systems

    E-Print Network [OSTI]

    Yang, Yang; Zhu, Qi; Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

    2012-01-01T23:59:59.000Z

    design flow for building automation systems that focuses onflow for building automation and control systems,’’ in Proc.Development of Building Automation and Control Systems Yang

  10. Automated Lattice Perturbation Theory

    SciTech Connect (OSTI)

    Monahan, Christopher

    2014-11-01T23:59:59.000Z

    I review recent developments in automated lattice perturbation theory. Starting with an overview of lattice perturbation theory, I focus on the three automation packages currently "on the market": HiPPy/HPsrc, Pastor and PhySyCAl. I highlight some recent applications of these methods, particularly in B physics. In the final section I briefly discuss the related, but distinct, approach of numerical stochastic perturbation theory.

  11. Automated pavement crack detection

    E-Print Network [OSTI]

    Rao, Ashok Madhava

    1991-01-01T23:59:59.000Z

    : Electrical Engineering AUTOMATED PAVEMENT CRACK DETECTION A Thesis by ASHOK MADHAVA RAO Approved as to style and content by . c Norman C. Grisw d (Chair of Committ ) Nasser Kehtarnavaz (Member) g, J~, Karan Watson Robert L. Lytt (Member) Jo W.... Howze (Head of Department) December 1991 111 ABSTRACT Automated Pavement Crack Detection. (December 1991) Ashok Madhava, Rao, B. E. , Mysore University Chair of Advisory Committee: Norman. C. Griswold Due to load, environmental and structural...

  12. General approach to automation of FLASH subsystems

    E-Print Network [OSTI]

    General approach to automation of FLASH subsystems Boguslaw Kosda #12;Agenda Motivation Nature of automation software for high energy experiments. Ultimate role of the automation software: Maximization of lasers availability. Automation of routine activities as startup, shutdown ... Continuous monitoring

  13. Automated Fault Location In Smart Distribution Systems 

    E-Print Network [OSTI]

    Lotfifard, Saeed

    2012-10-19T23:59:59.000Z

    ............................................................................................................................ 88 x LIST OF FIGURES Page Figure 1 Multiple possible fault location estimation for a fault at node A ........................ 7 Figure 2 Simple faulted network model [1] © [2011] IEEE ............................................ 40 Figure 3... Types C and D voltage sags for different phases [51] © [2003] IEEE .............. 42 Figure 4 Rf estimation procedure [1] © [2011] IEEE ...................................................... 45 Figure 5 Flow chart of the fault location algorithm [1...

  14. Automated Fault Location In Smart Distribution Systems

    E-Print Network [OSTI]

    Lotfifard, Saeed

    2012-10-19T23:59:59.000Z

    Quality Meters (PQM), are installed to capture harmonics and certain disturbances for analyzing the power quality indices. Digital Protective Relays are utilized to detect occurrence of the faults and isolate faulted section as fast as possible. Digital... Protective Relays) use synchronous methods [28]. Therefore, if the available data is provided by RTUs, fault location methods that operate based on direct comparison of the input samples cannot be 17 utilized. However, if the data could be gathered from...

  15. Automated Systematic Testing of Open Distributed Programs

    E-Print Network [OSTI]

    Sen, Koushik

    to alternate behaviors. At the same time, we use the concrete execution to determine, at runtime, the partial behaviors. At the same time, we use the concrete execution to guide the symbolic execution along a distinct, to explore all distinct behaviors that may result from a program's execution given different data inputs

  16. Automated Systematic Testing of Open Distributed Programs

    E-Print Network [OSTI]

    Sen, Koushik

    . At the same time, we use the concrete execution to determine, at runtime, the partial order of events. At the same time, we use the concrete execution to guide the symbolic execution along a distinct execution behaviors that may result from a program's execution given different data inputs and schedules. The key idea

  17. Distributed Automated Demand Response - Energy Innovation Portal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField Campaign:INEA : Papers SubfoldersU.S. Refining

  18. Automated Fresnel lens tester system

    SciTech Connect (OSTI)

    Phipps, G.S.

    1981-07-01T23:59:59.000Z

    An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

  19. Automated gas chromatography

    DOE Patents [OSTI]

    Mowry, Curtis D. (Albuquerque, NM); Blair, Dianna S. (Albuquerque, NM); Rodacy, Philip J. (Albuquerque, NM); Reber, Stephen D. (Corrales, NM)

    1999-01-01T23:59:59.000Z

    An apparatus and process for the continuous, near real-time monitoring of low-level concentrations of organic compounds in a liquid, and, more particularly, a water stream. A small liquid volume of flow from a liquid process stream containing organic compounds is diverted by an automated process to a heated vaporization capillary where the liquid volume is vaporized to a gas that flows to an automated gas chromatograph separation column to chromatographically separate the organic compounds. Organic compounds are detected and the information transmitted to a control system for use in process control. Concentrations of organic compounds less than one part per million are detected in less than one minute.

  20. Space-based solar power generation using a distributed network of satellites and methods for efficient space power transmission

    E-Print Network [OSTI]

    McLinko, Ryan M.

    Space-based solar power (SSP) generation is being touted as a solution to our ever-increasing energy consumption and dependence on fossil fuels. Satellites in Earth's orbit can capture solar energy through photovoltaic ...

  1. In situ diagnostic of the size distribution of nanoparticles generated by ultrashort pulsed laser ablation in vacuum

    SciTech Connect (OSTI)

    Bourquard, Florent; Loir, Anne-Sophie; Donnet, Christophe; Garrelie, Florence, E-mail: florence.garrelie@univ-st-etienne.fr [Université de Lyon, CNRS UMR 5516, Laboratoire Hubert Curien, Université Jean Monnet, Saint-Étienne (France)] [Université de Lyon, CNRS UMR 5516, Laboratoire Hubert Curien, Université Jean Monnet, Saint-Étienne (France)

    2014-03-10T23:59:59.000Z

    We aim to characterize the size distribution of nanoparticles located in the ablation plume produced by femtosecond laser interaction. The proposed method relies on the use of white-light extinction spectroscopy setup assisted by ultrafast intensified temporal gating. This method allows measurement of optical absorbance of a nickel nanoparticles cloud. Simulation of the extinction section of nickel nanoparticles size distributions has been developed in order to compare the measured optical absorbance to the optical extinction by theoretical and experimental nanoparticles size distributions (measured by scanning electron microscopy). A good agreement has been found between the in situ measured optical absorbance and the optical extinction cross section calculated from ex situ nanoparticles size distribution measurements.

  2. Automation of Capacity Bidding with an Aggregator Using Open Automated Demand Response

    E-Print Network [OSTI]

    Kiliccote, Sila

    2011-01-01T23:59:59.000Z

    Protocol for Building Automation and Control  Networks.  Protocol for Building Automation and Control  Networks, Demand Response Automation Server  Demand Response Research 

  3. Office Automation Document Preparation

    E-Print Network [OSTI]

    North Carolina at Chapel Hill, University of

    .2 Distinctions 1.3 Facilities 1.3.1 Document Preparation 1.3.2 Records Management 1.3.3 Communication 1 organizations contemplating the installation of document-preparation systems. * Administrative managersOffice Automation and Document Preparation for the v' University of North Carolina at Chapel Hill

  4. Automated Microbial Genome Annotation

    SciTech Connect (OSTI)

    Land, Miriam [DOE Joint Genome Institute at Oak Ridge National Laboratory

    2009-05-29T23:59:59.000Z

    Miriam Land of the DOE Joint Genome Institute at Oak Ridge National Laboratory gives a talk on the current state and future challenges of moving toward automated microbial genome annotation at the "Sequencing, Finishing, Analysis in the Future" meeting in Santa Fe, NM

  5. automated serum chemistry: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Summary: Test Automation Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2013 Mousavi: Test Automation 12;Test Automation...

  6. Net Metering Policy Development and Distributed Solar Generation in Minnesota: Overview of Trends in Nationwide Policy Development and Implications of Increasing the Eligible System Size Cap

    SciTech Connect (OSTI)

    Doris, E.; Busche, S.; Hockett, S.

    2009-12-01T23:59:59.000Z

    The goal of the Minnesota net metering policy is to give the maximum possible encouragement to distributed generation assets, especially solar electric systems (MN 2008). However, according to a published set of best practices (NNEC 2008) that prioritize the maximum development of solar markets within states, the Minnesota policy does not incorporate many of the important best practices that may help other states transform their solar energy markets and increase the amount of grid-connected distributed solar generation assets. Reasons cited include the low system size limit of 40kW (the best practices document recommends a 2 MW limit) and a lack of language protecting generators from additional utility fees. This study was conducted to compare Minnesota's policies to national best practices. It provides an overview of the current Minnesota policy in the context of these best practices and other jurisdictions' net metering policies, as well as a qualitative assessment of the impacts of raising the system size cap within the policy based on the experiences of other states.

  7. Automated analysis for detecting beams in laser wakefield simulations

    SciTech Connect (OSTI)

    Ushizima, Daniela M.; Rubel, Oliver; Prabhat, Mr.; Weber, Gunther H.; Bethel, E. Wes; Aragon, Cecilia R.; Geddes, Cameron G.R.; Cormier-Michel, Estelle; Hamann, Bernd; Messmer, Peter; Hagen, Hans

    2008-07-03T23:59:59.000Z

    Laser wakefield particle accelerators have shown the potential to generate electric fields thousands of times higher than those of conventional accelerators. The resulting extremely short particle acceleration distance could yield a potential new compact source of energetic electrons and radiation, with wide applications from medicine to physics. Physicists investigate laser-plasma internal dynamics by running particle-in-cell simulations; however, this generates a large dataset that requires time-consuming, manual inspection by experts in order to detect key features such as beam formation. This paper describes a framework to automate the data analysis and classification of simulation data. First, we propose a new method to identify locations with high density of particles in the space-time domain, based on maximum extremum point detection on the particle distribution. We analyze high density electron regions using a lifetime diagram by organizing and pruning the maximum extrema as nodes in a minimum spanning tree. Second, we partition the multivariate data using fuzzy clustering to detect time steps in a experiment that may contain a high quality electron beam. Finally, we combine results from fuzzy clustering and bunch lifetime analysis to estimate spatially confined beams. We demonstrate our algorithms successfully on four different simulation datasets.

  8. The Automated Palomar 60-Inch Telescope

    E-Print Network [OSTI]

    Cenko, S B; Moon, D S; Harrison, F A; Kulkarni, S R; Henning, J R; Guzman, C D; Bonati, M; Smith, R M; Thicksten, R P; Doyle, M W; Petrie, H L; Gal-Yam, A; Soderberg, A M; Anagnostou, N L; Laity, A C; Fox, Derek B.; Moon, Dae-Sik; Harrison, Fiona A.; Henning, John R.; Bonati, Marco; Smith, Roger M.; Thicksten, Robert P.; Doyle, Michael W.; Petrie, Hal L.; Gal-Yam, Avishay; Soderberg, Alicia M.; Anagnostou, Nathaniel L.; Laity, Anastasia C.

    2006-01-01T23:59:59.000Z

    We have converted the Palomar 60-inch telescope (P60) from a classical night assistant-operated telescope to a fully robotic facility. The automated system, which has been operational since September 2004, is designed for moderately fast (t <~ 3 minutes) and sustained (R <~ 23 mag) observations of gamma-ray burst afterglows and other transient events. Routine queue-scheduled observations can be interrupted in response to electronic notification of transient events. An automated pipeline reduces data in real-time, which is then stored on a searchable web-based archive for ease of distribution. We describe here the design requirements, hardware and software upgrades, and lessons learned from roboticization. We present an overview of the current system performance as well as plans for future upgrades.

  9. The Automated Palomar 60-Inch Telescope

    E-Print Network [OSTI]

    S. Bradley Cenko; Derek B. Fox; Dae-Sik Moon; Fiona A. Harrison; S. R. Kulkarni; John R. Henning; C. Dani Guzman; Marco Bonati; Roger M. Smith; Robert P. Thicksten; Michael W. Doyle; Hal L. Petrie; Avishay Gal-Yam; Alicia M. Soderberg; Nathaniel L. Anagnostou; Anastasia C. Laity

    2006-08-15T23:59:59.000Z

    We have converted the Palomar 60-inch telescope (P60) from a classical night assistant-operated telescope to a fully robotic facility. The automated system, which has been operational since September 2004, is designed for moderately fast (t <~ 3 minutes) and sustained (R <~ 23 mag) observations of gamma-ray burst afterglows and other transient events. Routine queue-scheduled observations can be interrupted in response to electronic notification of transient events. An automated pipeline reduces data in real-time, which is then stored on a searchable web-based archive for ease of distribution. We describe here the design requirements, hardware and software upgrades, and lessons learned from roboticization. We present an overview of the current system performance as well as plans for future upgrades.

  10. Evaluation on double-wall-tube residual stress distribution of sodium-heated steam generator by neutron diffraction and numerical analysis

    SciTech Connect (OSTI)

    Kisohara, N. [Advanced Nuclear System Research and Development Directorate, Japan Atomic Energy Agency (Japan); Suzuki, H.; Akita, K. [Quantum Beam Science Directorate, Japan Atomic Energy Agency (Japan); Kasahara, N. [Dept. of Nuclear Engineering and Management, Univ. of Tokyo (Japan)

    2012-07-01T23:59:59.000Z

    A double-wall-tube is nominated for the steam generator heat transfer tube of future sodium fast reactors (SFRs) in Japan, to decrease the possibility of sodium/water reaction. The double-wall-tube consists of an inner tube and an outer tube, and they are mechanically contacted to keep the heat transfer of the interface between the inner and outer tubes by their residual stress. During long term SG operation, the contact stress at the interface gradually falls down due to stress relaxation. This phenomenon might increase the thermal resistance of the interface and degrade the tube heat transfer performance. The contact stress relaxation can be predicted by numerical analysis, and the analysis requires the data of the initial residual stress distributions in the tubes. However, unclear initial residual stress distributions prevent precious relaxation evaluation. In order to resolve this issue, a neutron diffraction method was employed to reveal the tri-axial (radius, hoop and longitudinal) initial residual stress distributions in the double-wall-tube. Strain gauges also were used to evaluate the contact stress. The measurement results were analyzed using a JAEA's structural computer code to determine the initial residual stress distributions. Based on the stress distributions, the structural computer code has predicted the transition of the relaxation and the decrease of the contact stress. The radial and longitudinal temperature distributions in the tubes were input to the structural analysis model. Since the radial thermal expansion difference between the inner (colder) and outer (hotter) tube reduces the contact stress and the tube inside steam pressure contributes to increasing it, the analytical model also took these effects into consideration. It has been conduced that the inner and outer tubes are contacted with sufficient stresses during the plant life time, and that effective heat transfer degradation dose not occur in the double-wall-tube SG. (authors)

  11. Fuel Cell Power Model Version 2: Startup Guide, System Designs, and Case Studies. Modeling Electricity, Heat, and Hydrogen Generation from Fuel Cell-Based Distributed Energy Systems

    SciTech Connect (OSTI)

    Steward, D.; Penev, M.; Saur, G.; Becker, W.; Zuboy, J.

    2013-06-01T23:59:59.000Z

    This guide helps users get started with the U.S. Department of Energy/National Renewable Energy Laboratory Fuel Cell Power (FCPower) Model Version 2, which is a Microsoft Excel workbook that analyzes the technical and economic aspects of high-temperature fuel cell-based distributed energy systems with the aim of providing consistent, transparent, comparable results. This type of energy system would provide onsite-generated heat and electricity to large end users such as hospitals and office complexes. The hydrogen produced could be used for fueling vehicles or stored for later conversion to electricity.

  12. Automated gas chromatography

    DOE Patents [OSTI]

    Mowry, C.D.; Blair, D.S.; Rodacy, P.J.; Reber, S.D.

    1999-07-13T23:59:59.000Z

    An apparatus and process for the continuous, near real-time monitoring of low-level concentrations of organic compounds in a liquid, and, more particularly, a water stream. A small liquid volume of flow from a liquid process stream containing organic compounds is diverted by an automated process to a heated vaporization capillary where the liquid volume is vaporized to a gas that flows to an automated gas chromatograph separation column to chromatographically separate the organic compounds. Organic compounds are detected and the information transmitted to a control system for use in process control. Concentrations of organic compounds less than one part per million are detected in less than one minute. 7 figs.

  13. Theorie des langages Automates `a pile

    E-Print Network [OSTI]

    Bonzon, Elise

    Th´eorie des langages Automates `a pile Elise Bonzon http://web.mi.parisdescartes.fr/ bonzon/ elise.bonzon@parisdescartes.fr 1 / 62 Th´eorie des langages #12;Automates `a pile Automates `a pile Introduction Rappels sur les piles Automates `a pile : d´efinition Automates `a pile : configurations Les crit`eres d

  14. Methodology for Prototyping Increased Levels of Automation

    E-Print Network [OSTI]

    Valasek, John

    of automation than previous NASA vehicles, due to program requirements for automation, including Automated Ren into a human space flight vehicle, NASA has created the Function-specific Level of Autonomy and Automation Tool levels of automation than previous NASA vehicles. A key technology to the success of the CEV

  15. INTEGRATED CONTROL OF NEXT GENERATION POWER SYSTEM

    SciTech Connect (OSTI)

    None

    2010-02-28T23:59:59.000Z

    Control methodologies provide the necessary data acquisition, analysis and corrective actions needed to maintain the state of an electric power system within acceptable operating limits. These methods are primarily software-based algorithms that are nonfunctional unless properly integrated with system data and the appropriate control devices. Components of the control of power systems today include protective relays, supervisory control and data acquisition (SCADA), distribution automation (DA), feeder automation, software agents, sensors, control devices and communications. Necessary corrective actions are still accomplished using large electromechanical devices such as vacuum, oil and gas-insulated breakers, capacitor banks, regulators, transformer tap changers, reclosers, generators, and more recently FACTS (flexible AC transmission system) devices. The recent evolution of multi-agent system (MAS) technologies has been reviewed and effort made to integrate MAS into next generation power systems. A MAS can be defined as ��a loosely-coupled network of problem solvers that work together to solve problems that are beyond their individual capabilities��. These problem solvers, often called agents, are autonomous and may be heterogeneous in nature. This project has shown that a MAS has significant advantages over a single, monolithic, centralized problem solver for next generation power systems. Various communication media are being used in the electric power system today, including copper, optical fiber and power line carrier (PLC) as well as wireless technologies. These technologies have enabled the deployment of substation automation (SA) at many facilities. Recently, carrier and wireless technologies have been developed and demonstrated on a pilot basis. Hence, efforts have been made by this project to penetrate these communication technologies as an infrastructure for next generation power systems. This project has thus pursued efforts to use specific MAS methods as well as pertinent communications protocols to imbed and assess such technologies in a real electric power distribution system, specifically the Circuit of the Future (CoF) developed by Southern California Edison (SCE). By modeling the behavior and communication for the components of a MAS, the operation and control of the power distribution circuit have been enhanced. The use of MAS to model and integrate a power distribution circuit offers a significantly different approach to the design of next generation power systems. For example, ways to control a power distribution circuit that includes a micro-grid while considering the impacts of thermal constraints, and integrating voltage control and renewable energy sources on the main power system have been pursued. Both computer simulations and laboratory testbeds have been used to demonstrate such technologies in electric power distribution systems. An economic assessment of MAS in electric power systems was also performed during this project. A report on the economic feasibility of MAS for electric power systems was prepared, and particularly discusses the feasibility of incorporating MAS in transmission and distribution (T&D) systems. Also, the commercial viability of deploying MAS in T&D systems has been assessed by developing an initial case study using utility input to estimate the benefits of deploying MAS. In summary, the MAS approach, which had previously been investigated with good success by APERC for naval shipboard applications, has now been applied with promising results for enhancing an electric power distribution circuit, such as the Circuit of the Future developed by Southern California Edison. The results for next generation power systems include better ability to reconfigure circuits, improve protection and enhance reliability.

  16. Automated Job Hazards Analysis

    Broader source: Energy.gov [DOE]

    AJHA Program - The Automated Job Hazard Analysis (AJHA) computer program is part of an enhanced work planning process employed at the Department of Energy's Hanford worksite. The AJHA system is routinely used to performed evaluations for medium and high risk work, and in the development of corrective maintenance work packages at the site. The tool is designed to ensure that workers are fully involved in identifying the hazards, requirements, and controls associated with tasks.

  17. Power spectrum estimates of high frequency noise generated by high impedance arcing faults on distribution systems / by Thomas James Talley

    E-Print Network [OSTI]

    Talley, Thomas James

    1979-01-01T23:59:59.000Z

    faults, and to search for possible solutions, Pennsylvania Power and Light Company (PP&L) gathered data on instances of downed conductors. [ 4 ] In a breakdown of 390 cases of downed conductors on 12 KV overhead distribution lines in 1974...-75, they found that over- current protective devices did not operate for 23%%d of the cases where the feeder had bare wire conductors, and 727. of the cases where the feeder had XLP covered conductors. These figures indicate the severity of the problem...

  18. Analysis of Voltage Rise Effect on Distribution Network with Distributed

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Analysis of Voltage Rise Effect on Distribution Network with Distributed Generation M. A. Mahmud.hossain@adfa.edu.au, and H.Pota@adfa.edu.au). Abstract: Connections of distributed generation (DG) in distribution networks are increasing. These connections of distributed generation cause voltage rise in the distribution network

  19. Automation of Painted Slate Inspection

    E-Print Network [OSTI]

    Whelan, Paul F.

    Automation of Painted Slate Inspection BY Tim Carew (B.Eng.) carewt@eeng.dcu.ie Submitted...........................................................................................................18 2.1 Prior research on inspection of slates

  20. Valliappa Lakshmanan Automating the Analysis of

    E-Print Network [OSTI]

    Lakshmanan, Valliappa

    Geospatial Images January 5, 2012 Springer #12;Contents 1 Automated Analysis of Spatial Grids: MotivationValliappa Lakshmanan Automating the Analysis of Spatial Grids A Practitioner's Guide to Data Mining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.5 Challenges in Automated Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1

  1. automation: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  2. Service Reliability Measurement Using Automated Fare Card Data Application to the London Underground

    E-Print Network [OSTI]

    Uniman, David L.

    This paper explores the potential of using automated fare card data to quantify the reliability of service as experienced by passengers of rail transit systems. The distribution of individual passenger journey times can ...

  3. Automated Web Page Synthesis in Adaptive Web Systems

    E-Print Network [OSTI]

    Ghorbani, Ali

    Automated Web Page Synthesis in Adaptive Web Systems Hossein Sadat and Ali Ghorbani Intelligent, Canada {t15h7,ghorbani}@unb.ca Abstract. An adaptive Web system adapts the Web pages to its users, based of the system. In this paper, we formalize dynamic generation of Web pages and refer to it as Web page synthesis

  4. Automated Non-Destructive Testing Array Evaluation System

    SciTech Connect (OSTI)

    T.Wei, N.Zavaljevski, S.Bakhtiari, A.Miron, D.Kupperman

    2004-12-31T23:59:59.000Z

    Utilities perform eddy current tests on nuclear power plant steam generator (SG) tubes to detect degradation. This report summarizes the status of ongoing research to develop signal processing algorithms that automate analysis of eddy current test data. The research focuses on analyzing array probe data for detecting, classifying, and characterizing degradation in SG tubes.

  5. Automated Circuit Breaker Monitoring U.S. DOE CERTS Project

    E-Print Network [OSTI]

    Reliability Technology Solutions (CERTS), and funded by the Office of Electric Transmission and Distribution a portion of the power system is very critical task and circuit breakers must be very reliableAutomated Circuit Breaker Monitoring U.S. DOE CERTS Project Power Systems Engineering Research

  6. Medical and Home automation Sensor Networks for Senior Citizens Telehomecare

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    of building smart homes named "Vill'Âge" at France. Keywords: Telemedicine, Tele-Healthcare, Elderly Healthcare, Smart Home, Distributed health record, Actimetry, Fuzzy logic, Home automation I. INTRODUCTION and Internet technologies have a key role in the development of smart homes. Healthcare integrated smart homes

  7. Installation and Commissioning Automated Demand Response Systems

    E-Print Network [OSTI]

    Kiliccote, Sila; Global Energy Partners; Pacific Gas and Electric Company

    2008-01-01T23:59:59.000Z

    their partnership in demand response automation research andand Techniques for Demand Response. LBNL Report 59975. Mayof Fully Automated Demand Response in Large Facilities.

  8. Home Network Technologies and Automating Demand Response

    E-Print Network [OSTI]

    McParland, Charles

    2010-01-01T23:59:59.000Z

    and Automating Demand Response Charles McParland, Lawrenceand Automating Demand Response Charles McParland, LBNLCommercial and Residential Demand Response Overview of the

  9. Installation and Commissioning Automated Demand Response Systems

    E-Print Network [OSTI]

    Kiliccote, Sila; Global Energy Partners; Pacific Gas and Electric Company

    2008-01-01T23:59:59.000Z

    al: Installation and Commissioning Automated Demand ResponseConference on Building Commissioning: April 22 – 24, 2008al: Installation and Commissioning Automated Demand Response

  10. Integration of automation design information using XML technologies

    E-Print Network [OSTI]

    Integration of automation design information using XML technologies Master of Science Thesis Mika Degree Program Institute of Automation and Control Viinikkala, Mika: Integration of automation design Software Ltd., Metso Automation, and TEKES Department of Automation June 2002 Keywords: System integration

  11. Methods for Analyzing the Benefits and Costs of Distributed Photovoltaic Generation to the U.S. Electric Utility System

    SciTech Connect (OSTI)

    Denholm, P.; Margolis, R.; Palmintier, B.; Barrows, C.; Ibanez, E.; Bird, L.; Zuboy, J.

    2014-09-01T23:59:59.000Z

    This report outlines the methods, data, and tools that could be used at different levels of sophistication and effort to estimate the benefits and costs of DGPV. In so doing, we identify the gaps in current benefit-cost-analysis methods, which we hope will inform the ongoing research agenda in this area. The focus of this report is primarily on benefits and costs from the utility or electricity generation system perspective. It is intended to provide useful background information to utility and regulatory decision makers and their staff, who are often being asked to use or evaluate estimates of the benefits and cost of DGPV in regulatory proceedings. Understanding the technical rigor of the range of methods and how they might need to evolve as DGPV becomes a more significant contributor of energy to the electricity system will help them be better consumers of this type of information. This report is also intended to provide information to utilities, policy makers, PV technology developers, and other stakeholders, which might help them maximize the benefits and minimize the costs of integrating DGPV into a changing electricity system.

  12. Economic feasibility analysis of distributed electric power generation based upon the natural gas-fired fuel cell. Final report

    SciTech Connect (OSTI)

    Not Available

    1994-03-01T23:59:59.000Z

    The final report provides a summary of results of the Cost of Ownership Model and the circumstances under which a distributed fuel cell is economically viable. The analysis is based on a series of micro computer models estimate the capital and operations cost of a fuel cell central utility plant configuration. Using a survey of thermal and electrical demand profiles, the study defines a series of energy user classes. The energy user class demand requirements are entered into the central utility plant model to define the required size the fuel cell capacity and all supporting equipment. The central plant model includes provisions that enables the analyst to select optional plant features that are most appropriate to a fuel cell application, and that are cost effective. The model permits the choice of system features that would be suitable for a large condominium complex or a residential institution such as a hotel, boarding school or prison. Other applications are also practical; however, such applications have a higher relative demand for thermal energy, a characteristic that is well-suited to a fuel cell application with its free source of hot water or steam. The analysis combines the capital and operation from the preceding models into a Cost of Ownership Model to compute the plant capital and operating costs as a function of capacity and principal features and compares these estimates to the estimated operating cost of the same central plant configuration without a fuel cell.

  13. Honeywell Modular Automation System Computer Software Documentation

    SciTech Connect (OSTI)

    STUBBS, A.M.

    2000-12-04T23:59:59.000Z

    The purpose of this Computer Software Document (CSWD) is to provide configuration control of the Honeywell Modular Automation System (MAS) in use at the Plutonium Finishing Plant (PFP). This CSWD describes hardware and PFP developed software for control of stabilization furnaces. The Honeywell software can generate configuration reports for the developed control software. These reports are described in the following section and are attached as addendum's. This plan applies to PFP Engineering Manager, Thermal Stabilization Cognizant Engineers, and the Shift Technical Advisors responsible for the Honeywell MAS software/hardware and administration of the Honeywell System.

  14. Automated inspection of hot steel slabs

    DOE Patents [OSTI]

    Martin, Ronald J. (Burnsville, MN)

    1985-01-01T23:59:59.000Z

    The disclosure relates to a real time digital image enhancement system for performing the image enhancement segmentation processing required for a real time automated system for detecting and classifying surface imperfections in hot steel slabs. The system provides for simultaneous execution of edge detection processing and intensity threshold processing in parallel on the same image data produced by a sensor device such as a scanning camera. The results of each process are utilized to validate the results of the other process and a resulting image is generated that contains only corresponding segmentation that is produced by both processes.

  15. Automated inspection of hot steel slabs

    DOE Patents [OSTI]

    Martin, R.J.

    1985-12-24T23:59:59.000Z

    The disclosure relates to a real time digital image enhancement system for performing the image enhancement segmentation processing required for a real time automated system for detecting and classifying surface imperfections in hot steel slabs. The system provides for simultaneous execution of edge detection processing and intensity threshold processing in parallel on the same image data produced by a sensor device such as a scanning camera. The results of each process are utilized to validate the results of the other process and a resulting image is generated that contains only corresponding segmentation that is produced by both processes. 5 figs.

  16. Automated fiber pigtailing machine

    DOE Patents [OSTI]

    Strand, O.T.; Lowry, M.E.

    1999-01-05T23:59:59.000Z

    The Automated Fiber Pigtailing Machine (AFPM) aligns and attaches optical fibers to optoelectronic (OE) devices such as laser diodes, photodiodes, and waveguide devices without operator intervention. The so-called pigtailing process is completed with sub-micron accuracies in less than 3 minutes. The AFPM operates unattended for one hour, is modular in design and is compatible with a mass production manufacturing environment. This machine can be used to build components which are used in military aircraft navigation systems, computer systems, communications systems and in the construction of diagnostics and experimental systems. 26 figs.

  17. Automated fiber pigtailing machine

    DOE Patents [OSTI]

    Strand, Oliver T. (Castro Valley, CA); Lowry, Mark E. (Castro Valley, CA)

    1999-01-01T23:59:59.000Z

    The Automated Fiber Pigtailing Machine (AFPM) aligns and attaches optical fibers to optoelectonic (OE) devices such as laser diodes, photodiodes, and waveguide devices without operator intervention. The so-called pigtailing process is completed with sub-micron accuracies in less than 3 minutes. The AFPM operates unattended for one hour, is modular in design and is compatible with a mass production manufacturing environment. This machine can be used to build components which are used in military aircraft navigation systems, computer systems, communications systems and in the construction of diagnostics and experimental systems.

  18. MASS: An automated accountability system

    SciTech Connect (OSTI)

    Erkkila, B.H.; Kelso, F.

    1994-08-01T23:59:59.000Z

    All Department of Energy contractors who manage accountable quantities of nuclear materials are required to implement an accountability system that tracks, and records the activities associated with those materials. At Los Alamos, the automated accountability system allows data entry on computer terminals and data base updating as soon as the entry is made. It is also able to generate all required reports in a timely Fashion. Over the last several years, the hardware and software have been upgraded to provide the users with all the capability needed to manage a large variety of operations with a wide variety of nuclear materials. Enhancements to the system are implemented as the needs of the users are identified. The system has grown with the expanded needs of the user; and has survived several years of changing operations and activity. The user community served by this system includes processing, materials control and accountability, and nuclear material management personnel. In addition to serving the local users, the accountability system supports the national data base (NMMSS). This paper contains a discussion of several details of the system design and operation. After several years of successful operation, this system provides an operating example of how computer systems can be used to manage a very dynamic data management problem.

  19. Towards Automated Service Composition using Policy Ontology in Building Automation System

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Towards Automated Service Composition using Policy Ontology in Building Automation System Son N.crespi}@it-sudparis.eu Abstract--Automated service composition is critical for suc- cessfully implementing Building Automation-service composition; semantic web; policy; ontol- ogy; building automation system; I. INTRODUCTION In building

  20. L3 Informatique Automates et langages formels 4 mars 2009 TD 5 : Automates `a pile

    E-Print Network [OSTI]

    Schmitz, Sylvain

    L3 Informatique Automates et langages formels 4 mars 2009 TD 5 : Automates `a pile Exercice 1 (Exemples d'automates `a pile). Donner un automate `a pile A = Q, , Z, T, q0, z0, F pour chacun des trois pile. Montrer que l'on peut construire un automate `a pile A ´equivalent avec une relation de

  1. ABV-A Low Speed Automation Project to Study the Technical Feasibility of Fully Automated Driving

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    on vehicle automation since many years. From 1987 to 1995 the European Commission funded the 800 million concepts of vehicles designed as fully automated vehicles [1]. Beyond its fully automation ability Automated Highway System Consortium (NAHSC) that demonstrated about 20 automated vehicles in Demo'97 on I-15

  2. Communication in automation, including networking and wireless

    E-Print Network [OSTI]

    Antsaklis, Panos

    Communication in automation, including networking and wireless Nicholas Kottenstette and Panos J and networking in automation is given. Digital communication fundamentals are reviewed and networked control are presented. 1 Introduction 1.1 Why communication is necessary in automated systems Automated systems use

  3. automated on-line separation-preconcentration: Topics by E-print...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Automation 12;Test Automation Outline Test Automation Mousavi: Test Automation 12;Test Automation Why? Challenges of Manual Testing Test-case design: Choosing inputs Mousavi,...

  4. automated on-line solvent: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Automation 12;Test Automation Outline Test Automation Mousavi: Test Automation 12;Test Automation Why? Challenges of Manual Testing Test-case design: Choosing inputs Mousavi,...

  5. Robust automated knowledge capture.

    SciTech Connect (OSTI)

    Stevens-Adams, Susan Marie; Abbott, Robert G.; Forsythe, James Chris; Trumbo, Michael Christopher Stefan; Haass, Michael Joseph; Hendrickson, Stacey M. Langfitt

    2011-10-01T23:59:59.000Z

    This report summarizes research conducted through the Sandia National Laboratories Robust Automated Knowledge Capture Laboratory Directed Research and Development project. The objective of this project was to advance scientific understanding of the influence of individual cognitive attributes on decision making. The project has developed a quantitative model known as RumRunner that has proven effective in predicting the propensity of an individual to shift strategies on the basis of task and experience related parameters. Three separate studies are described which have validated the basic RumRunner model. This work provides a basis for better understanding human decision making in high consequent national security applications, and in particular, the individual characteristics that underlie adaptive thinking.

  6. Automated Verification of Quantum Protocols using MCMAS

    E-Print Network [OSTI]

    F. Belardinelli; P. Gonzalez; A. Lomuscio

    2012-07-04T23:59:59.000Z

    We present a methodology for the automated verification of quantum protocols using MCMAS, a symbolic model checker for multi-agent systems The method is based on the logical framework developed by D'Hondt and Panangaden for investigating epistemic and temporal properties, built on the model for Distributed Measurement-based Quantum Computation (DMC), an extension of the Measurement Calculus to distributed quantum systems. We describe the translation map from DMC to interpreted systems, the typical formalism for reasoning about time and knowledge in multi-agent systems. Then, we introduce dmc2ispl, a compiler into the input language of the MCMAS model checker. We demonstrate the technique by verifying the Quantum Teleportation Protocol, and discuss the performance of the tool.

  7. Participation through Automation: Fully Automated Critical Peak Pricing in Commercial Buildings

    E-Print Network [OSTI]

    Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Kiliccote, Sila; Linkugel, Eric

    2006-01-01T23:59:59.000Z

    Figure 2. Demand Response Automation Server and BuildingII system to notify the Automation Server of an up comingoccurs day-ahead). 2. The Automation Server posts two pieces

  8. Automation of Termination: Abstracting CCG through MWG Automation of Termination: Abstracting Calling

    E-Print Network [OSTI]

    Ayala-Rincón, Mauricio

    Automation of Termination: Abstracting CCG through MWG Automation of Termination: Abstracting of Termination: Abstracting CCG through MWG Motivation Termination analysis is a fundamental topic in computer science. While classical results state the undecidability of various termination problems, automated

  9. Aspects of automation mode confusion

    E-Print Network [OSTI]

    Wheeler, Paul H. (Paul Harrison)

    2007-01-01T23:59:59.000Z

    Complex systems such as commercial aircraft are difficult for operators to manage. Designers, intending to simplify the interface between the operator and the system, have introduced automation to assist the operator. In ...

  10. A Survey of Automated Deduction 

    E-Print Network [OSTI]

    Bundy, Alan

    We survey research in the automation of deductive inference, from its beginnings in the early history of computing to the present day. We identify and describe the major areas of research interest and their applications. ...

  11. Automated Assembly Using Feature Localization

    E-Print Network [OSTI]

    Gordon, Steven Jeffrey

    1986-12-01T23:59:59.000Z

    Automated assembly of mechanical devices is studies by researching methods of operating assembly equipment in a variable manner; that is, systems which may be configured to perform many different assembly operations ...

  12. Facilities Automation and Energy Management

    E-Print Network [OSTI]

    Jen, D. P.

    1983-01-01T23:59:59.000Z

    Computerized facilities automation and energy management systems can be used to maintain high levels of facilities operations efficiencies. The monitoring capabilities provides the current equipment and process status, and the analysis...

  13. The potential for distributed generation in Japanese prototype buildings: A DER-CAM analysis of policy, tariff design, building energy use, and technology development (English Version)

    SciTech Connect (OSTI)

    Zhou, Nan; Marnay, Chris; Firestone, Ryan; Gao, Weijun; Nishida, Masaru

    2004-10-15T23:59:59.000Z

    The August 2003 blackout of the northeastern U.S. and CANADA caused great economic losses and inconvenience to New York City and other affected areas. The blackout was a warning to the rest of the world that the ability of conventional power systems to meet growing electricity demand is questionable. Failure of large power systems can lead to serious emergencies. Introduction of on-site generation, renewable energy such as solar and wind power and the effective utilization of exhaust heat is needed, to meet the growing energy demands of the residential and commercial sectors. Additional benefit can be achieved by integrating these distributed technologies into distributed energy resource (DER) systems. This work demonstrates a method for choosing and designing economically optimal DER systems. An additional purpose of this research is to establish a database of energy tariffs, DER technology cost and performance characteristics, and building energy consumption for Japan. This research builds on prior DER studies at the Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) and with their associates in the Consortium for Electric Reliability Technology Solutions (CERTS) and operation, including the development of the microgrid concept, and the DER selection optimization program, the Distributed Energy Resources Customer Adoption Model (DER-CAM). DER-CAM is a tool designed to find the optimal combination of installed equipment and an idealized operating schedule to minimize a site's energy bills, given performance and cost data on available DER technologies, utility tariffs, and site electrical and thermal loads over a test period, usually an historic year. Since hourly electric and thermal energy data are rarely available, they are typically developed by building simulation for each of six end use loads used to model the building: electric-only loads, space heating, space cooling, refrigeration, water heating, and natural-gas-only loads. DER-CAM provides a global optimization, albeit idealized, that shows how the necessary useful energy loads can be provided for at minimum cost by selection and operation of on-site generation, heat recovery, cooling, and efficiency improvements. This study examines five prototype commercial buildings and uses DER-CAM to select the economically optimal DER system for each. The five building types are office, hospital, hotel, retail, and sports facility. Each building type was considered for both 5,000 and 10,000 square meter floor sizes. The energy consumption of these building types is based on building energy simulation and published literature. Based on the optimization results, energy conservation and the emissions reduction were also evaluated. Furthermore, a comparison study between Japan and the U.S. has been conducted covering the policy, technology and the utility tariffs effects on DER systems installations. This study begins with an examination of existing DER research. Building energy loads were then generated through simulation (DOE-2) and scaled to match available load data in the literature. Energy tariffs in Japan and the U.S. were then compared: electricity prices did not differ significantly, while commercial gas prices in Japan are much higher than in the U.S. For smaller DER systems, the installation costs in Japan are more than twice those in the U.S., but this difference becomes smaller with larger systems. In Japan, DER systems are eligible for a 1/3 rebate of installation costs, while subsidies in the U.S. vary significantly by region and application. For 10,000 m{sup 2} buildings, significant decreases in fuel consumption, carbon emissions, and energy costs were seen in the economically optimal results. This was most noticeable in the sports facility, followed the hospital and hotel. This research demonstrates that office buildings can benefit from CHP, in contrast to popular opinion. For hospitals and sports facilities, the use of waste heat is particularly effective for water and space heating. For the other building types, waste heat is most effectively use

  14. Role of Standard Demand Response Signals for Advanced Automated Aggregation

    E-Print Network [OSTI]

    Kiliccote, Sila

    2013-01-01T23:59:59.000Z

    for the Open Automated Demand Response (OpenADR) StandardsControl for Automated Demand Response, Grid Interop, 2009. [C. McParland, Open Automated Demand Response Communications

  15. Scenarios for Consuming Standardized Automated Demand Response Signals

    E-Print Network [OSTI]

    Koch, Ed

    2009-01-01T23:59:59.000Z

    of Fully Automated Demand Response in Large Facilities.Fully Automated Demand Response Tests in Large Facilities.Interoperable Automated Demand Response Infrastructure.

  16. Open Automated Demand Response for Small Commerical Buildings

    E-Print Network [OSTI]

    Dudley, June Han

    2009-01-01T23:59:59.000Z

    of Fully Automated Demand  Response in Large Facilities.  Fully Automated Demand Response Tests in Large Facilities.  Open Automated  Demand Response Communication Standards: 

  17. automation simulation system: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and the future expectations and challenges in process automation and power system automation. Anannya Mukherjee 9 Emergency Vehicle Maneuvers and Control Laws for Automated...

  18. EIA - Distributed Generation in Buildings

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for On-Highway4,1,50022,3,,,,6,1,9,1,50022,3,,,,6,1,Decade Year-0E (2001)gasoline353/06) 2YonthlyEnergy Markets 9,Analysis

  19. Design and Implementation of an Open, Interoperable AutomatedDemand Response Infrastructure

    SciTech Connect (OSTI)

    Piette, Mary Ann; Kiliccote, Sila; Ghatikar, Girish

    2007-10-01T23:59:59.000Z

    This paper describes the concept for and lessons from the development and field-testing of an open, interoperable communications infrastructure to support automating demand response (DR). Automating DR allows greater levels of participation and improved reliability and repeatability of the demand response and customer facilities. Automated DR systems have been deployed for critical peak pricing and demand bidding and are being designed for real time pricing. The system is designed to generate, manage, and track DR signals between utilities and Independent System Operators (ISOs) to aggregators and end-use customers and their control systems.

  20. Automation in image cytometry : continuous HCS and kinetic image cytometry

    E-Print Network [OSTI]

    Charlot, David J.

    2012-01-01T23:59:59.000Z

    OF CALIFORNIA, SAN DIEGO Automation in Image Cytometry:xiv Abstract of Dissertation Automation in Image Cytometry:

  1. Automated Demand Response Opportunities in Wastewater Treatment Facilities

    E-Print Network [OSTI]

    Thompson, Lisa

    2008-01-01T23:59:59.000Z

    Interoperable Automated Demand Response Infrastructure,study of automated demand response in wastewater treatmentopportunities for demand response control strategies in

  2. Linking Continuous Energy Management and Open Automated Demand Response

    E-Print Network [OSTI]

    Piette, Mary Ann

    2009-01-01T23:59:59.000Z

    Linking Continuous Energy Management and Open AutomatedKeywords: Continuous Energy Management, Automated Demandlinking continuous energy management and continuous

  3. AUTOMATING THE SELECTION OF FENESTRATION SYSTEMS TO BEST MEET DAYLIGHTING PERFORMANCE GOALS

    E-Print Network [OSTI]

    AUTOMATING THE SELECTION OF FENESTRATION SYSTEMS TO BEST MEET DAYLIGHTING PERFORMANCE GOALS Luís closer to producing the desired flux distribution from the outdoor daylight distribution. INTRODUCTION The selection of fenestration systems for daylighting is traditionally done by trial and error. Designers try

  4. Transport Research Arena Europe 2010, Brussels Towards Highly Automated Driving

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    of HAVEit is to develop and investigate vehicle automation beyond ADAS systems, especially highly automated automated vehicles In 2010, two lines of research and development exist in the domain of ground vehicle automation: Either the automation is driving the vehicle fully automated without a human driver

  5. Disciplined agility for process control & automation

    E-Print Network [OSTI]

    Tibazarwa, Augustine

    2009-01-01T23:59:59.000Z

    Process automation vendors must consider agility as a basis to gain a competitive edge in innovation. Process Automation systems can impact the operating cost of manufacturing equipment, the safe control of large quantities ...

  6. Technical University of Denmark rsted DTU Automation

    E-Print Network [OSTI]

    Technical University of Denmark �rsted · DTU Automation Project: SICAM - SIngle Conversion stage based SICAM using an LC-network Petar Ljusev, MSc., Ph.D. student, �rsted · DTU Automation e-mail: pl

  7. The Automation Of Proof By Mathematical Induction 

    E-Print Network [OSTI]

    Bundy, Alan

    This paper is a chapter of the Handbook of Automated Reasoning edited by Voronkov and Robinson. It describes techniques for automated reasoning in theories containing rules of mathematical induction. Firstly, inductive reasoning is defined and its...

  8. Technical University of Denmark rsted DTU Automation

    E-Print Network [OSTI]

    Technical University of Denmark �rsted · DTU Automation Project: SICAM - SIngle Conversion stage, �rsted · DTU Automation e-mail: pl@oersted.dtu.dk Abstract In this report an isolated PWM DC-AC SICAM

  9. INTRODUCTION Sophisticated automation is becoming ubiq-

    E-Print Network [OSTI]

    Lee, John D.

    INTRODUCTION Sophisticated automation is becoming ubiq- uitous, appearing in work environments as di- verse as aviation, maritime operations, process control, motor vehicle operation, and informa- tion retrieval. Automation is technology that actively selects data, transforms information, makes

  10. TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING 1 Automated Guiding Task of a Flexible Micropart

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING 1 Automated Guiding Task of a Flexible Micropart Lutz, Member, IEEE Abstract--This paper studies automated tasks based on hybrid force/position control of automated guiding task are presented. Note to Practitioners -- This article's motivation is the need of very

  11. An Ontology-based Model to Determine the Automation Level of an Automated Vehicle for

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    An Ontology-based Model to Determine the Automation Level of an Automated Vehicle for Co). In addition, an automated vehicle should also self-assess its own perception abilities, and not only perceive this idea, cybercars were designed as fully automated vehicles [3], thought since its inception as a new

  12. High-efficiency grid-connected photovoltaic module integrated converter system with high-speed communication interfaces for small-scale distribution power generation

    SciTech Connect (OSTI)

    Choi, Woo-Young; Lai, Jih-Sheng (Jason) [Future Energy Electronics Center, Department of Electrical and Computer Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA (United States)

    2010-04-15T23:59:59.000Z

    This paper presents a high-efficiency grid-connected photovoltaic (PV) module integrated converter (MIC) system with reduced PV current variation. The proposed PV MIC system consists of a high-efficiency step-up DC-DC converter and a single-phase full-bridge DC-AC inverter. An active-clamping flyback converter with a voltage-doubler rectifier is proposed for the step-up DC-DC converter. The proposed step-up DC-DC converter reduces the switching losses by eliminating the reverse-recovery current of the output rectifying diodes. To reduce the PV current variation introduced by the grid-connected inverter, a PV current variation reduction method is also suggested. The suggested PV current variation reduction method reduces the PV current variation without any additional components. Moreover, for centralized power control of distributed PV MIC systems, a PV power control scheme with both a central control level and a local control level is presented. The central PV power control level controls the whole power production by sending out reference power signals to each individual PV MIC system. The proposed step-up DC-DC converter achieves a high-efficiency of 97.5% at 260 W output power to generate the DC-link voltage of 350 V from the PV voltage of 36.1 V. The PV MIC system including the DC-DC converter and the DC-AC inverter achieves a high-efficiency of 95% with the PV current ripple less than 3% variation of the rated PV current. (author)

  13. Automated Verification of Practical Garbage Collectors

    E-Print Network [OSTI]

    Hawblitzel, Chris

    2010-01-01T23:59:59.000Z

    Garbage collectors are notoriously hard to verify, due to their low-level interaction with the underlying system and the general difficulty in reasoning about reachability in graphs. Several papers have presented verified collectors, but either the proofs were hand-written or the collectors were too simplistic to use on practical applications. In this work, we present two mechanically verified garbage collectors, both practical enough to use for real-world C# benchmarks. The collectors and their associated allocators consist of x86 assembly language instructions and macro instructions, annotated with preconditions, postconditions, invariants, and assertions. We used the Boogie verification generator and the Z3 automated theorem prover to verify this assembly language code mechanically. We provide measurements comparing the performance of the verified collector with that of the standard Bartok collectors on off-the-shelf C# benchmarks, demonstrating their competitiveness.

  14. Automated behavioural fingerprinting of C. elegans mutants

    E-Print Network [OSTI]

    Brown, André E X

    2013-01-01T23:59:59.000Z

    Rapid advances in genetics, genomics, and imaging have given insight into the molecular and cellular basis of behaviour in a variety of model organisms with unprecedented detail and scope. It is increasingly routine to isolate behavioural mutants, clone and characterise mutant genes, and discern the molecular and neural basis for a behavioural phenotype. Conversely, reverse genetic approaches have made it possible to straightforwardly identify genes of interest in whole-genome sequences and generate mutants that can be subjected to phenotypic analysis. In this latter approach, it is the phenotyping that presents the major bottleneck; when it comes to connecting phenotype to genotype in freely behaving animals, analysis of behaviour itself remains superficial and time consuming. However, many proof-of-principle studies of automated behavioural analysis over the last decade have poised the field on the verge of exciting developments that promise to begin closing this gap. In the broadest sense, our goal in this...

  15. Automated Immobilized Metal Affinity Chromatography System for...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Immobilized Metal Affinity Chromatography System for Enrichment of Escherichia coli Phosphoproteome. Automated Immobilized Metal Affinity Chromatography System for Enrichment of...

  16. INTEGRATING AUTOMATION DESIGN INFORMATION WITH XML

    E-Print Network [OSTI]

    INTEGRATING AUTOMATION DESIGN INFORMATION WITH XML Mika Viinikkala, Seppo Kuikka Institute of Automation and Control, Tampere University of Technology, P.O. Box 692, 33101 Tampere, Finland Email: mika.viinikkala@tut.fi, seppo.kuikka@tut.fi Keywords: Systems integration, XML, automation design Abstract: This paper presents

  17. Comparison lamps automation CTIO 60 inches Echelle

    E-Print Network [OSTI]

    Tokovinin, Andrei A.

    Comparison lamps automation CTIO 60 inches Echelle ECH60S5.1 La Serena, December 09, 2009 #12)...............................................................................12 CTIO 60 inches Echelle / Comparison lamps automation, ECH60S5.1 2 #12;Introduction The present document is just a brief summary of the work done automating the 60 inches echelle comparison lamps

  18. TAMPERE UNIVERSITY OF TECHNOLOGY DEPARTMENT OF AUTOMATION

    E-Print Network [OSTI]

    TAMPERE UNIVERSITY OF TECHNOLOGY DEPARTMENT OF AUTOMATION An Intelligent Web Service for Operation 2004 Examiner: Prof. Seppo Kuikka #12;2 Abstract TAMPERE UNIVERSITY OF TECHNOLOGY Automation Degree Program Institute of Automation and Control Jaakkola, Veli-Pekka: An Intelligent Web Service for Operation

  19. Comparison lamps automation CTIO 60 inches CHIRON

    E-Print Network [OSTI]

    Tokovinin, Andrei A.

    Comparison lamps automation CTIO 60 inches CHIRON CHI60HF5.2 La Serena, March 16, 2011 #12;Table)...............................................................................12 CTIO 60 inches Chiron / Comparison lamps automation, CHI60HF5.2 2 #12;Introduction The present document is just a brief summary of the work done automating the 60 inches chiron comparison lamps

  20. Prparation l'agrgation Automates pile

    E-Print Network [OSTI]

    Schmitz, Sylvain

    Préparation à l'agrégation Automates à pile Exercice 1 (Exemples de langages reconnus par automate à pile) Montrer que les langages suivants sont reconnus par automate à pile : 1. Le langage de Dyck. 2. {an bp | 0 pile) 1. Montrer que

  1. Feasible Path Synthesis for Automated Guided Vehicles

    E-Print Network [OSTI]

    Vuik, Kees

    Feasible Path Synthesis for Automated Guided Vehicles Reijer Idema 2005 TU Delft FROG Navigation for Automated Guided Vehicles Author: Reijer Idema Supervisors: prof.dr.ir. P. Wesseling (TU Delft) dr.ir. Kees is a manufacturer of Automated Guided Vehicles. They have developed a multitude of vehicles that transport products

  2. Automated Purge Valve Joseph Edward Farrell, III.

    E-Print Network [OSTI]

    Wood, Stephen L.

    Automated Purge Valve by Joseph Edward Farrell, III. Bachelor of Science Marine Engineering the undersigned committee hereby approve the attached thesis Automated Purge Valve by Joseph Edward Farrell, III.D. Department Head Department of Marine and Environmental Systems #12;iii Abstract Title: Automated Purge Valve

  3. AUTOMATED CRITICAL PEAK PRICING FIELD TESTS

    E-Print Network [OSTI]

    ) for development of the DR Automation Server System This project could not have been completed without extensive: Greg Watson and Mark Lott · C&C Building Automation: Mark Johnson and John Fiegel · Chabot Space AUTOMATED CRITICAL PEAK PRICING FIELD TESTS: 2006 PROGRAM DESCRIPTION AND RESULTS

  4. Automated packing systems: Review of industrial implementations.

    E-Print Network [OSTI]

    Whelan, Paul F.

    Automated packing systems: Review of industrial implementations. Paul F. Whelan School in these applications. An outline of one such industrial application, the automated placement of shape templates Mathematics University of Wales Cardiff, Wales. ABSTRACT The problems involved in the automated packing

  5. The potential for distributed generation in Japanese prototype buildings: A DER-CAM analysis of policy, tariff design, building energy use, and technology development (English Version)

    E-Print Network [OSTI]

    Zhou, Nan; Marnay, Chris; Firestone, Ryan; Gao, Weijun; Nishida, Masaru

    2004-01-01T23:59:59.000Z

    Industry, Japan MT microturbine NEGA Japan Engine GeneratorGE), gas turbine (GT), microturbine (MT), fuel cell (FC),Fuel Cell Gas Turbine Microturbine Natual Gas Reciprocating

  6. High-resolution radial Ka spectra obtained from a multi-keV electron distribution in solid-density titanium foils generated by relativistic laserematter interaction

    E-Print Network [OSTI]

    Kroupp, Eyal

    -density titanium foils generated by relativistic laserematter interaction U. Zastrau a,*, A. Sengebusch b , P s t r a c t We studied temperature and Ka yield radial profiles of thin titanium foils as a result in novel experiments generating high energy plasma in materials and will be of particular importance

  7. Specimen coordinate automated measuring machine/fiducial automated measuring machine

    DOE Patents [OSTI]

    Hedglen, Robert E. (Bethel Park, PA); Jacket, Howard S. (Pittsburgh, PA); Schwartz, Allan I. (Turtle Creek, PA)

    1991-01-01T23:59:59.000Z

    The Specimen coordinate Automated Measuring Machine (SCAMM) and the Fiducial Automated Measuring Machine (FAMM) is a computer controlled metrology system capable of measuring length, width, and thickness, and of locating fiducial marks. SCAMM and FAMM have many similarities in their designs, and they can be converted from one to the other without taking them out of the hot cell. Both have means for: supporting a plurality of samples and a standard; controlling the movement of the samples in the +/- X and Y directions; determining the coordinates of the sample; compensating for temperature effects; and verifying the accuracy of the measurements and repeating as necessary. SCAMM and FAMM are designed to be used in hot cells.

  8. Real time automated inspection

    DOE Patents [OSTI]

    Fant, K.M.; Fundakowski, R.A.; Levitt, T.S.; Overland, J.E.; Suresh, B.R.; Ulrich, F.W.

    1985-05-21T23:59:59.000Z

    A method and apparatus are described relating to the real time automatic detection and classification of characteristic type surface imperfections occurring on the surfaces of material of interest such as moving hot metal slabs produced by a continuous steel caster. A data camera transversely scans continuous lines of such a surface to sense light intensities of scanned pixels and generates corresponding voltage values. The voltage values are converted to corresponding digital values to form a digital image of the surface which is subsequently processed to form an edge-enhanced image having scan lines characterized by intervals corresponding to the edges of the image. The edge-enhanced image is thresholded to segment out the edges and objects formed by the edges by interval matching and bin tracking. Features of the objects are derived and such features are utilized to classify the objects into characteristic type surface imperfections. 43 figs.

  9. Real time automated inspection

    DOE Patents [OSTI]

    Fant, Karl M. (Minneapolis, MN); Fundakowski, Richard A. (Saint Paul, MN); Levitt, Tod S. (Minneapolis, MN); Overland, John E. (Plymouth, MN); Suresh, Bindinganavle R. (New Brighton, MN); Ulrich, Franz W. (Minneapolis, MN)

    1985-01-01T23:59:59.000Z

    A method and apparatus relating to the real time automatic detection and classification of characteristic type surface imperfections occurring on the surfaces of material of interest such as moving hot metal slabs produced by a continuous steel caster. A data camera transversely scans continuous lines of such a surface to sense light intensities of scanned pixels and generates corresponding voltage values. The voltage values are converted to corresponding digital values to form a digital image of the surface which is subsequently processed to form an edge-enhanced image having scan lines characterized by intervals corresponding to the edges of the image. The edge-enhanced image is thresholded to segment out the edges and objects formed by the edges are segmented out by interval matching and bin tracking. Features of the objects are derived and such features are utilized to classify the objects into characteristic type surface imperfections.

  10. Context-based automated defect classification system using multiple morphological masks

    DOE Patents [OSTI]

    Gleason, Shaun S. (Knoxville, TN); Hunt, Martin A. (Knoxville, TN); Sari-Sarraf, Hamed (Lubbock, TX)

    2002-01-01T23:59:59.000Z

    Automatic detection of defects during the fabrication of semiconductor wafers is largely automated, but the classification of those defects is still performed manually by technicians. This invention includes novel digital image analysis techniques that generate unique feature vector descriptions of semiconductor defects as well as classifiers that use these descriptions to automatically categorize the defects into one of a set of pre-defined classes. Feature extraction techniques based on multiple-focus images, multiple-defect mask images, and segmented semiconductor wafer images are used to create unique feature-based descriptions of the semiconductor defects. These feature-based defect descriptions are subsequently classified by a defect classifier into categories that depend on defect characteristics and defect contextual information, that is, the semiconductor process layer(s) with which the defect comes in contact. At the heart of the system is a knowledge database that stores and distributes historical semiconductor wafer and defect data to guide the feature extraction and classification processes. In summary, this invention takes as its input a set of images containing semiconductor defect information, and generates as its output a classification for the defect that describes not only the defect itself, but also the location of that defect with respect to the semiconductor process layers.

  11. Automating the determination of 3D protein structure

    SciTech Connect (OSTI)

    Rayl, K.D.

    1993-12-31T23:59:59.000Z

    The creation of an automated method for determining 3D protein structure would be invaluable to the field of biology and presents an interesting challenge to computer science. Unfortunately, given the current level of protein knowledge, a completely automated solution method is not yet feasible, therefore, our group has decided to integrate existing databases and theories to create a software system that assists X-ray crystallographers in specifying a particular protein structure. By breaking the problem of determining overall protein structure into small subproblems, we hope to come closer to solving a novel structure by solving each component. By generating necessary information for structure determination, this method provides the first step toward designing a program to determine protein conformation automatically.

  12. Automated nutrient analyses in seawater

    SciTech Connect (OSTI)

    Whitledge, T.E.; Malloy, S.C.; Patton, C.J.; Wirick, C.D.

    1981-02-01T23:59:59.000Z

    This manual was assembled for use as a guide for analyzing the nutrient content of seawater samples collected in the marine coastal zone of the Northeast United States and the Bering Sea. Some modifications (changes in dilution or sample pump tube sizes) may be necessary to achieve optimum measurements in very pronounced oligotrophic, eutrophic or brackish areas. Information is presented under the following section headings: theory and mechanics of automated analysis; continuous flow system description; operation of autoanalyzer system; cookbook of current nutrient methods; automated analyzer and data analysis software; computer interfacing and hardware modifications; and trouble shooting. The three appendixes are entitled: references and additional reading; manifold components and chemicals; and software listings. (JGB)

  13. Automated Demand Response and Commissioning

    SciTech Connect (OSTI)

    Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Bourassa, Norman

    2005-04-01T23:59:59.000Z

    This paper describes the results from the second season of research to develop and evaluate the performance of new Automated Demand Response (Auto-DR) hardware and software technology in large facilities. Demand Response (DR) is a set of activities to reduce or shift electricity use to improve the electric grid reliability and manage electricity costs. Fully-Automated Demand Response does not involve human intervention, but is initiated at a home, building, or facility through receipt of an external communications signal. We refer to this as Auto-DR. The evaluation of the control and communications must be properly configured and pass through a set of test stages: Readiness, Approval, Price Client/Price Server Communication, Internet Gateway/Internet Relay Communication, Control of Equipment, and DR Shed Effectiveness. New commissioning tests are needed for such systems to improve connecting demand responsive building systems to the electric grid demand response systems.

  14. Automated manual transmission controller

    DOE Patents [OSTI]

    Lawrie, Robert E. (Whitmore Lake, MI); Reed, Jr., Richard G. (Royal Oak, MI); Bernier, David R. (Rochester Hills, MI)

    1999-12-28T23:59:59.000Z

    A powertrain system for a hybrid vehicle. The hybrid vehicle includes a heat engine, such as a diesel engine, and an electric machine, which operates as both an electric motor and an alternator, to power the vehicle. The hybrid vehicle also includes a manual-style transmission configured to operate as an automatic transmission from the perspective of the driver. The engine and the electric machine drive an input shaft which in turn drives an output shaft of the transmission. In addition to driving the transmission, the electric machine regulates the speed of the input shaft in order to synchronize the input shaft during either an upshift or downshift of the transmission by either decreasing or increasing the speed of the input shaft. When decreasing the speed of the input shaft, the electric motor functions as an alternator to produce electrical energy which may be stored by a storage device. Operation of the transmission is controlled by a transmission controller which receives input signals and generates output signals to control shift and clutch motors to effect smooth launch, upshift shifts, and downshifts of the transmission, so that the transmission functions substantially as an automatic transmission from the perspective of the driver, while internally substantially functioning as a manual transmission.

  15. Automated Generation of BPEL Adapters Antonio Brogi and Razvan Popescu

    E-Print Network [OSTI]

    Brogi, Antonio

    is the use of service contracts [6] including WSDL signatures and YAWL behaviour, where YAWL [13] is used

  16. automated hydride generation-cryotrapping-atomic: Topics by E...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Mohammad 3 Geoneutrino and Hydridic Earth model CERN Preprints Summary: Uranium, Thorium and Potassium-40 abundances in the Earth were calculated in the frame of Hydridic...

  17. Automated Inclusive Design Heuristics Generation with Graph Mining

    E-Print Network [OSTI]

    Sangelkar, Shraddha Chandrakant

    2013-08-01T23:59:59.000Z

    Inclusive design is a concept intended to promote the development of products and environments equally usable by all users, irrespective of their age or ability. This research focuses on developing a method to derive heuristics for inclusive design...

  18. Convection automated logic oven control

    SciTech Connect (OSTI)

    Boyer, M.A.; Eke, K.I. [Apollo U.S.A. Inc., Orlando, FL (United States)] [Apollo U.S.A. Inc., Orlando, FL (United States)

    1998-03-01T23:59:59.000Z

    For the past few years, there has been a greater push to bring more automation to the cooling process. There have been attempts at automated cooking using a wide range of sensors and procedures, but with limited success. The authors have the answer to the automated cooking process; this patented technology is called Convection AutoLogic (CAL). The beauty of the technology is that it requires no extra hardware for the existing oven system. They use the existing temperature probe, whether it is an RTD, thermocouple, or thermistor. This means that the manufacturer does not have to be burdened with extra costs associated with automated cooking in comparison to standard ovens. The only change to the oven is the program in the central processing unit (CPU) on the board. As for its operation, when the user places the food into the oven, he or she is required to select a category (e.g., beef, poultry, or casseroles) and then simply press the start button. The CAL program then begins its cooking program. It first looks at the ambient oven temperature to see if it is a cold, warm, or hot start. CAL stores this data and then begins to look at the food`s thermal footprint. After CAL has properly detected this thermal footprint, it can calculate the time and temperature at which the food needs to be cooked. CAL then sets up these factors for the cooking stage of the program and, when the food has finished cooking, the oven is turned off automatically. The total time for this entire process is the same as the standard cooking time the user would normally set. The CAL program can also compensate for varying line voltages and detect when the oven door is opened. With all of these varying factors being monitored, CAL can produce a perfectly cooked item with minimal user input.

  19. Automated Liquid Microjunction Surface Sampling-HPLC-MS/MS Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections

    SciTech Connect (OSTI)

    Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

    2013-01-01T23:59:59.000Z

    A fully automated liquid extraction-based surface sampling system utilizing a commercially available autosampler coupled to high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) detection is reported. Discrete spots selected for droplet-based sampling and automated sample queue generation for both the autosampler and MS were enabled by using in-house developed software. In addition, co-registration of spatially resolved sampling position and HPLC-MS information to generate heatmaps of compounds monitored for subsequent data analysis was also available in the software. The system was evaluated with whole-body thin tissue sections from propranolol dosed rat. The hands-free operation of the system was demonstrated by creating heatmaps of the parent drug and its hydroxypropranolol glucuronide metabolites with 1 mm resolution in the areas of interest. The sample throughput was approximately 5 min/sample defined by the time needed for chromatographic separation. The spatial distributions of both the drug and its metabolites were consistent with previous studies employing other liquid extraction-based surface sampling methodologies.

  20. Automation of Capacity Bidding with an Aggregator Using Open Automated Demand Response

    E-Print Network [OSTI]

    Kiliccote, Sila

    2011-01-01T23:59:59.000Z

    program, demand  response aggregator, demand response  vii WITH AN AGGREGATOR USING OPEN AUTOMATED DEMAND RESPONSE ThisWith an Aggregator Using Open Automated Demand Response is 

  1. Automation of Capacity Bidding with an Aggregator Using Open Automated Demand Response

    E-Print Network [OSTI]

    Kiliccote, Sila

    2011-01-01T23:59:59.000Z

    and industrial facilities.   The long?term vision is to embed the  automation Industrial/Agricultural/Water End?Use Energy Efficiency  Renewable Energy Technologies  Transportation  The Automation 

  2. Sandia National Laboratories: Small Generator Interconnection...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Commission Revised Its Small Generator Interconnection Procedure and Small Generator Interconnection Agreement On March 4, 2014, in Distribution Grid Integration, Energy, Grid...

  3. The effects of level of automation and adaptive automation on human performance, situation awareness and workload in a

    E-Print Network [OSTI]

    Kaber, David B.

    The effects of level of automation and adaptive automation on human performance, situation., 4731 East Forest Peak, Marietta, GA 30066, USA Keywords: Level of automation (LOA); adaptive automation of automation (LOAs) for maintaining operator involvement in complex systems control and facilitating situation

  4. Thorie des Langages -TD 7 AUTOMATES PILE

    E-Print Network [OSTI]

    Bonzon, Elise

    Théorie des Langages - TD 7 AUTOMATES � PILE Exercice 1 - Donnez deux automates à pile (acceptation par pile vide ; par état final) qui reconnaissent chacun des langages suivants : 1. L1 = {anbm|n,m 0 l'automate à pile suivant reconnaissant le langage L par état final : 0 1 3 2 a, Z0/AZ0 , A/ a, A

  5. Automated Transportation Management System (ATMS) | Department...

    Broader source: Energy.gov (indexed) [DOE]

    of Energy's (DOE's) Automated Transportation Management System is an integrated web-based logistics management system allowing users to manage inbound and outbound freight...

  6. Automated micro-tracking planar solar concentrators

    E-Print Network [OSTI]

    Hallas, Justin Matthew

    2011-01-01T23:59:59.000Z

    E. Ford, “Reactive self-tracking solar concentration: designFord, “Reactive self- tracking solar concentration: designAutomated Micro-Tracking Planar Solar Concentrators by

  7. Automated Continuous Commissioning of Commercial Buildings

    E-Print Network [OSTI]

    Bailey, Trevor

    2013-01-01T23:59:59.000Z

    Conference on Building Commissioning. San Francisco, CA. 17.Commercial Buildings Commissioning, LBNL- 56637, Nov. 2004.Automated Continuous Commissioning Tool GUI Screenshots from

  8. LANL to certify automated influenza surveillance system

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    will design the automated high-throughput extraction and screening system for a prototype Global Bio Lab-a compact, modular laboratory that can reliably process thousands of...

  9. Safety Analysis Of Automated Highway Systems

    E-Print Network [OSTI]

    Leveson, Nancy G.

    1997-01-01T23:59:59.000Z

    Lee. Towards an automated fmea assis- tant. In Applicationsmodes and effects analysis (FMEA) is employed to determineof multiple failures. ) FMEA was developed Potential Part

  10. Honeywell Demonstrates Automated Demand Response Benefits for...

    Broader source: Energy.gov (indexed) [DOE]

    Honeywell's Smart Grid Investment Grant (SGIG) project demonstrates utility-scale performance of a hardwaresoftware platform for automated demand response (ADR). This project...

  11. Architectures of Test Automation Copyright Cem Kaner, 2000. All rights reserved. 1 Architectures of Test Automation

    E-Print Network [OSTI]

    Architectures of Test Automation Copyright © Cem Kaner, 2000. All rights reserved. 1 Architectures of Test Automation Copyright © August, 2000 Cem Kaner, kaner@kaner.com Acknowledgement Many of the ideas in this presentation were jointly developed with Doug Hoffman, in a course that we taught together on test automation

  12. REMOTE LABORATORIES IN AUTOMATION: AIP-PRIMECA RAO ARI PLATFORM Remote Laboratories in Automation

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    for thorough trainings in industrial We thank our sponsors : Schneider Electric which provided the automationREMOTE LABORATORIES IN AUTOMATION: AIP-PRIMECA RAO ARI PLATFORM Remote Laboratories in Automation of resources and competencies about industrial topics for many universities in Rhône-Alpes french Region. Due

  13. automated breast mass: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  14. automated basic driving: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  15. automated plate assay: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  16. automated endothelial keratoplasty: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  17. automated speed enforcement: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  18. automation study aids: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  19. automated fiber pigtailing: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  20. automated chemiluminescence immunoassays: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  1. automated quantitative nuclear: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  2. automated blood culture: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  3. automated potentiometric titrations: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  4. automating eccs switchover: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  5. automated sampling assessment: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  6. automated mounter enabling: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  7. automated personal dosimetry: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  8. automated checkin: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  9. automated elution time: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  10. automated enzyme immunoassays: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  11. automated edman degradation: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  12. automated air sampling: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  13. automated liquid handler: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  14. automated cytogenetic biodosimetry: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  15. automated endothelial keratoplastydsaek: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  16. automating breast radiation: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  17. automated liquid handlers: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  18. automated sample preparation: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  19. automated sample mounting: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  20. automated immunoradiometric assay: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  1. automated urine microscopy: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  2. automating collateral evolutions: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  3. automated affymetrix expression: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  4. automated pulmonary fissure: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  5. automated container terminal: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  6. automated peritoneal dialysis: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  7. automated gas tonometric: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  8. automated blood sampling: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  9. ammos automated molecular: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  10. automated steel cleanliness: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  11. automated nucleophilic 18ffluorination: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  12. automated pressure-controlled discography: Topics by E-print...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  13. automated clearance: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  14. automated radiometric technic: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  15. automated sample transfer: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  16. automated procalcitonin assay: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  17. automated hot embossing: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  18. automated dose dispensing: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Websites Summary: of a partial automation since they act on the control part of the vehicle. This increasing automationABV- A Low Speed Automation Project to Study the...

  19. Abundance and distribution of macro-crustaceans in the intake and discharge areas before and during early operation of the Cedar Bayou Generating Station

    E-Print Network [OSTI]

    Schmidt, Monroe

    1972-01-01T23:59:59.000Z

    and Discharge Areas Before and During Early Operation of the Cedar Bayou Generating Station. (May 1972) Monroe Schmidt, A. A. , Blinn College; B. S. , Texas A&M University Directed by: Dr. Kirk Strawn Two trawl and 1 seine station in Tabbs Bay, 2 trawl... were collected twice monthly from May through October 1970. Genera- tion of electric power (and discharge of heated water) by Unit 1, a 750 MW steam-electric unit of the Houston Lighting and Power Company's Cedar Bayou Generating Station, began...

  20. Interconnection Standards for Small Generators

    Broader source: Energy.gov [DOE]

    The Federal Energy Regulatory Commission (FERC) adopted "small generator" interconnection standards for distributed energy resources up to 20 megawatts (MW) in capacity in May 2005.* The FERC's...

  1. Knowledge Generation

    SciTech Connect (OSTI)

    BRABSON,JOHN M.; DELAND,SHARON M.

    2000-11-02T23:59:59.000Z

    Unattended monitoring systems are being studied as a means of reducing both the cost and intrusiveness of present nuclear safeguards approaches. Such systems present the classic information overload problem to anyone trying to interpret the resulting data not only because of the sheer quantity of data but also because of the problems inherent in trying to correlate information from more than one source. As a consequence, analysis efforts to date have mostly concentrated on checking thresholds or diagnosing failures. Clearly more sophisticated analysis techniques are required to enable automated verification of expected activities level concepts in order to make automated judgments about safety, sensor system integrity, sensor data quality, diversion, and accountancy.

  2. Automated Engineering of e-Business Processes The RosettaNet Case Study

    E-Print Network [OSTI]

    Finkelstein, Anthony

    , and such situation was reflected by process models and execution technologies. With business models now shifting engineered business processes. The efficiencies generated by process automation depend substantially resources accordingly. The resources and objectives involved in a business process impose very specific

  3. Automated, Retargetable Back-Annotation for Host Compiled Performance and Power Modeling

    E-Print Network [OSTI]

    Gerstlauer, Andreas

    and back- annotation of basic code blocks with all possible predeces- sors. Results from applying ourAutomated, Retargetable Back-Annotation for Host Compiled Performance and Power Modeling Suhas typical front- and back-end optimiza- tions by working at the compiler-generated intermediate rep

  4. Automated Detection of Non-Termination and NullPointerExceptions for Java Bytecode

    E-Print Network [OSTI]

    Ábrahám, Erika

    Automated Detection of Non-Termination and NullPointerExceptions for Java Bytecode Marc (JBC), which is based on constructing and analyzing termination graphs. These graphs represent all to detect non-termination or NullPointerExceptions. Our approach automatically generates witnesses, i

  5. FISH and Chips: Automation of Fluorescent Dot Counting in Interphase Cell Nuclei

    E-Print Network [OSTI]

    van Vliet, Lucas J.

    ) in each cell nucleus. This system works with two fluorescent dyes, one for the DNA hybridization dotsFISH and Chips: Automation of Fluorescent Dot Counting in Interphase Cell Nuclei Hans Netten,1 Ian abnormalities in inter- phase cell nuclei. This process is called dot counting. To estimate the distribution

  6. Thermodynamic estimation of minor element distribution between immiscible liquids in Fe-Cu-based metal phase generated in melting treatment of municipal solid wastes

    SciTech Connect (OSTI)

    Lu, X. [School of Metallurgical and Ecological Engineering, The University of Science and Technology Beijing, 30 Xueyuan Road, Haidian District, Beijing 100083 (China); Nakajima, K.; Sakanakura, H. [Research Center for Material Cycles and Waste Management, National Institute for Environmental Studies (NIES), 16-2 Onogawa, Tsukuba 305-8506 (Japan); Matsubae, K. [Graduate School of Engineering, Tohoku University, 6-6-11 Aza-Aoba, Aramaki, Sendai 980-8579 (Japan); Bai, H. [School of Metallurgical and Ecological Engineering, The University of Science and Technology Beijing, 30 Xueyuan Road, Haidian District, Beijing 100083 (China); Nagasaka, T., E-mail: t-nagasaka@m.tohoku.ac.jp [Graduate School of Engineering, Tohoku University, 6-6-11 Aza-Aoba, Aramaki, Sendai 980-8579 (Japan)

    2012-06-15T23:59:59.000Z

    Graphical abstract: Display Omitted Highlights: Black-Right-Pointing-Pointer Two liquids separation of metal occurs in the melting of municipal solid waste. Black-Right-Pointing-Pointer The distribution of PGMs etc. between two liquid metal phases is studied. Black-Right-Pointing-Pointer Quite simple thermodynamic model is applied to predict the distribution ratio. Black-Right-Pointing-Pointer Au and Ag originated from WEEE are found to be concentrated into Cu-rich phase. - Abstract: Waste electrical and electronic equipment (WEEE) has become an important target in managing material cycles from the viewpoint of not only waste management and control of environmental pollution but also resource conservation. This study investigated the distribution tendency of trace elements in municipal solid waste (MSW) or incinerator ash, including valuable non-ferrous metals (Ni, Co, Cr, Mn, Mo, Ti, V, W, Zr), precious group metals (PGMs) originated from WEEE (Ag, Au, Pd, Pt), and others (Al, B, Pb, Si), between Fe-rich and Cu-rich metal phases by means of simple thermodynamic calculations. Most of the typical alloying elements for steel (Co, Cr, Mo, Nb, Ni, Si, Ti, V, and W) and Rh were preferentially distributed into the Fe-rich phase. PGMs, such as Au, Ag, and Pd, were enriched in the Cu-rich phase, whereas Pt was almost equally distributed into both phases. Since the primary metallurgical processing of Cu is followed by an electrolysis for refining, and since PGMs in crude copper have been industrially recovered from the resulting anode slime, our results indicated that Ag, Au, and Pd could be effectively recovered from MSW if the Cu-rich phase could be selectively collected.

  7. Reference Model for Control and Automation Systems in Electrical...

    Office of Environmental Management (EM)

    Model for Control and Automation Systems in Electrical Power (October 2005) Reference Model for Control and Automation Systems in Electrical Power (October 2005) Modern...

  8. ISA Approves Standard for Wireless Automation in Process Control...

    Energy Savers [EERE]

    ISA Approves Standard for Wireless Automation in Process Control Applications ISA Approves Standard for Wireless Automation in Process Control Applications On September 9, the...

  9. V-132: IBM Tivoli System Automation Application Manager Multiple...

    Broader source: Energy.gov (indexed) [DOE]

    IBM has acknowledged multiple vulnerabilities in IBM Tivoli System Automation Application Manager PLATFORM: The vulnerabilities are reported in IBM Tivoli System Automation...

  10. Small- and Medium-Size Building Automation and Control System...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Emerging...

  11. Open Automated Demand Response Communications Specification (Version 1.0)

    E-Print Network [OSTI]

    Piette, Mary Ann

    2009-01-01T23:59:59.000Z

    and Techniques for Demand Response. May 2007. LBNL-59975.to facilitate automating  demand response actions at the Interoperable Automated Demand Response Infrastructure,

  12. Open Automated Demand Response Dynamic Pricing Technologies and Demonstration

    E-Print Network [OSTI]

    Ghatikar, Girish

    2010-01-01T23:59:59.000Z

    Goodin. 2009. “Open Automated Demand Response Communicationsin Demand Response for Wholesale Ancillary Services. ” InOpen Automated Demand Response Demonstration Project. LBNL-

  13. SciTech Connect: Multiplex automated genome engineering

    Office of Scientific and Technical Information (OSTI)

    Multiplex automated genome engineering Citation Details In-Document Search Title: Multiplex automated genome engineering You are accessing a document from the Department of...

  14. automated guideway transit: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Automated Data Collection Systems, such as Automated Fare Collection (AFC) and Automatic Vehicle Location (AVL), provides ... Schil, Mickal (Mickal Ren Jerme) 2012-01-01...

  15. automated file management: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    OverviewManaged Lanes OverviewManaged Lanes OverviewManaged Lanes Overview 2012 Road Vehicle Automation Workshop2012 Road Vehicle Automation Workshop Engineering Websites...

  16. automated toll collection: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Automated Data Collection Systems, such as Automated Fare Collection (AFC) and Automatic Vehicle Location (AVL), provides ... Schil, Mickal (Mickal Ren Jerme) 2012-01-01...

  17. automated transportation management: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    OverviewManaged Lanes OverviewManaged Lanes OverviewManaged Lanes Overview 2012 Road Vehicle Automation Workshop2012 Road Vehicle Automation Workshop Engineering Websites...

  18. automated concise extraction: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of Computer Science, Bar-Ilan University, Ramat-Gan 52900, Israel 4 Center for Automation Research, University of Maryland Plaza, Antonio J. 5 Automated Pointcut Extraction...

  19. automated rna extraction: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of Computer Science, Bar-Ilan University, Ramat-Gan 52900, Israel 4 Center for Automation Research, University of Maryland Plaza, Antonio J. 5 Automated Pointcut Extraction...

  20. automated relation extraction: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of Computer Science, Bar-Ilan University, Ramat-Gan 52900, Israel 4 Center for Automation Research, University of Maryland Plaza, Antonio J. 6 Automated Pointcut Extraction...

  1. automated ammunition logistics: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    major industrial accident. The origin times and number of explosions were key 3 Test Automation Test Automation Computer Technologies and Information Sciences Websites Summary:...

  2. Inventors in Action: Composites and Automation | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Composite Materials and Automation Inventors in Action: Composite Materials and Automation As our composite materials evolve, our manufacturing processes do too. A new class of...

  3. An automated tool for three types of saturated hydraulic conductivity...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    automated tool for three types of saturated hydraulic conductivity laboratory measurements. An automated tool for three types of saturated hydraulic conductivity laboratory...

  4. automated analysis tool: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and Information Sciences Websites Summary: automating tools or an open source DBMS whose lack of automated tools might increase the operational cost their benefits. We...

  5. automated words stability: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Coach that Listens: Automated Detection Mostow, Jack 38 Model-driven Automated Software FMEA Neal Snooke, PhD, Aberystwyth University Computer Technologies and Information Sciences...

  6. automated visual fields: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Approach to Sensor Selection- prehensive automated Failure Modes and Effects Analysis (FMEA) using qualitative model based reasoning au- tonomous aircraft. Automated failure mode...

  7. automated motif analysis: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Approach to Sensor Selection- prehensive automated Failure Modes and Effects Analysis (FMEA) using qualitative model based reasoning au- tonomous aircraft. Automated failure mode...

  8. analysis automation caa: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Approach to Sensor Selection- prehensive automated Failure Modes and Effects Analysis (FMEA) using qualitative model based reasoning au- tonomous aircraft. Automated failure mode...

  9. analysis automated perimetry: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Approach to Sensor Selection- prehensive automated Failure Modes and Effects Analysis (FMEA) using qualitative model based reasoning au- tonomous aircraft. Automated failure mode...

  10. automated risk analysis: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Approach to Sensor Selection- prehensive automated Failure Modes and Effects Analysis (FMEA) using qualitative model based reasoning au- tonomous aircraft. Automated failure mode...

  11. automated visual inspection: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Approach to Sensor Selection- prehensive automated Failure Modes and Effects Analysis (FMEA) using qualitative model based reasoning au- tonomous aircraft. Automated failure...

  12. automated quantitative analysis: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Approach to Sensor Selection- prehensive automated Failure Modes and Effects Analysis (FMEA) using qualitative model based reasoning au- tonomous aircraft. Automated failure...

  13. Open Automated Demand Response Communications Specification (Version 1.0)

    E-Print Network [OSTI]

    Piette, Mary Ann

    2009-01-01T23:59:59.000Z

    Keywords: demand response, buildings, electricity use, Interface  Automated Demand Response  Building Automation of demand response in  commercial buildings.   One key 

  14. Open Automated Demand Response for Small Commerical Buildings

    E-Print Network [OSTI]

    Dudley, June Han

    2009-01-01T23:59:59.000Z

    Demand  Response for Small Commercial Buildings.   CEC?500?automated demand response  For small commercial buildings, AUTOMATED DEMAND RESPONSE FOR SMALL COMMERCIAL BUILDINGS

  15. Method and apparatus for globally-accessible automated testing

    DOE Patents [OSTI]

    Layne, Scott P. (Los Angeles, CA); Beugelsdijk, Tony J. (Los Alamos, NM)

    1998-01-01T23:59:59.000Z

    A method and apparatus for sharing integrated testing services with a plurality of autonomous remote clients is disclosed. In the disclosed method, in response to an access request message, a process controller transmits an access enabling message to the remote client. The access enabling message includes instructions performable by a remote client to generate test equipment commands. A process controller interprets and transforms these commands into automated test instrument suite commands, which are provided to laboratory modules to perform the indicated tests. Test data results are then obtained and transmitted to the remote client.

  16. Automating An Industrial Power Plant 

    E-Print Network [OSTI]

    Williams, D. R.; McCowen, R. R.

    1987-01-01T23:59:59.000Z

    and electricity requirements of the Component Works as well as all of the heat and a portion of the electricity needed by the adjacent John Deere Foundry. This paper describes the automation of an eXisting industrial power plant and tells how the project...AUTlliATING AN INDUSTRIAL POWER PLANT DAVID R. WILLIAMS, P.E. Energy Coordi?nator John Deere Component Works Waterloo, Iowa ABSTRACT The need for an upgrade of boiler and turbine controls in the 15 MW coal-fired cogeneration plant...

  17. Automated mass spectrometer grows up

    SciTech Connect (OSTI)

    McInteer, B.B.; Montoya, J.G.; Stark, E.E.

    1984-01-01T23:59:59.000Z

    In 1980 we reported the development of an automated mass spectrometer for large scale batches of samples enriched in nitrogen-15 as ammonium salts. Since that time significant technical progress has been made in the instrument. Perhaps more significantly, administrative and institutional changes have permitted the entire effort to be transferred to the private sector from its original base at the Los Alamos National Laboratory. This has ensured the continuance of a needed service to the international scientific community as revealed by a development project at a national laboratory, and is an excellent example of beneficial technology transfer to private industry.

  18. Chapter VIII Automated Overlay of Infrared

    E-Print Network [OSTI]

    Hopgood, Adrian

    166 Chapter VIII Automated Overlay of Infrared and Visual Medical Images G. Schaefer Aston written permission of IGI Global is prohibited. AbstrAct Medical infrared imaging captures the temperature a useful diagnostic visualisation for the clinician. #12;167 Automated Overlay of Infrared and Visual

  19. Technical University of Denmark rsted DTU Automation

    E-Print Network [OSTI]

    Technical University of Denmark �rsted · DTU Automation Project: SICAM - SIngle Conversion stage;Isolated PDM and PWM DC-AC SICAMs Petar Ljusev, MSc., Ph.D. student, �rsted · DTU Automation e-mail: pl

  20. Demand Response and Open Automated Demand Response

    E-Print Network [OSTI]

    LBNL-3047E Demand Response and Open Automated Demand Response Opportunities for Data Centers G described in this report was coordinated by the Demand Response Research Center and funded by the California. Demand Response and Open Automated Demand Response Opportunities for Data Centers. California Energy