National Library of Energy BETA

Sample records for asd groups x-ray

  1. ROSAT X-ray Spectral Properties of Nearby Young Associations: TW Hydrae, Tucana-Horologium, and the beta Pic Moving Group

    E-Print Network [OSTI]

    Joel H. Kastner; Lara Crigger; Margaret Rich; David A. Weintraub

    2002-11-15

    We present archival ROSAT data for three recently identified, nearby (DPic Moving Group. The distributions of ROSAT X-ray hardness ratios (HR1, HR2) for these three groups, whose membership is dominated by low-mass, weak-lined T Tauri stars, are tightly clustered and very similar to one another. The value of HR1 for TW Hya itself -- the only bona fide classical T Tauri star in any of the nearby groups -- is clearly anomalous among these nearby young stars. We compare the hardness ratio distributions of stars in the three nearby groups with those of T Tauri stars, the Hyades, and main sequence dwarfs in the field. This comparison demonstrates that the X-ray spectra of F through M stars soften with age, and that F and G stars evolve more rapidly in X-ray spectral hardness than do K and M stars. It is as yet unclear whether this trend can be attributed to age-dependent changes in the intrinsic X-ray spectra of stars of type F and later, to a decrease in the column density of circumstellar gas (e.g., in residual protoplanetary disks), or to the diminishing contributions of star-disk interactions to X-ray emission. Regardless, these results demonstrate that analysis of archival ROSAT X-ray spectral data can help both to identify nearby, young associations and to ascertain the X-ray emission properties of members of known associations.

  2. X-Ray Evidence for Multiphase Hot Gas with Nearly Solar Fe Abundances in the Brightest Groups of Galaxies

    E-Print Network [OSTI]

    David A. Buote

    1999-08-27

    We analyze the ASCA spectra accumulated within ~100 kpc radii of 12 of the brightest groups of galaxies. Upon fitting isothermal models (1T) jointly to the ASCA SIS and GIS spectra we obtain fits for most groups that are of poor or at best marginal quality and give very sub-solar metallicities similar to previous studies, = 0.29 +/- 0.12 Z_sun. Two-temperature models (2T) provide significantly better fits for 11 out of the 12 groups and in every case have metallicities that are substantially larger than obtained for the 1T models, = 0.75 +/- 0.24 Z_sun. Although not very well constrained, for most of the groups absorption in excess of the Galactic value is indicated for the cooler temperature component of the 2T models. A simple multiphase cooling flow model gives results analogous to the 2T models including large metallicities, = 0.65 +/- 0.17 Z_sun. The nearly solar Fe abundances and also solar alpha/Fe ratios indicated by the 2T and cooling flow models are consistent with models of the chemical enrichment of ellipticals, groups, and clusters which assume ratios of Type Ia to Type II supernova and an IMF similar to those of the Milky Way. Thus, we have shown that the very sub-solar Fe abundances and Si/Fe enhancements obtained from most previous studies within r ~100 kpc of galaxy groups are an artifact of their fitting isothermal models to the X-ray spectra which also has been recently demonstrated for the brightest elliptical galaxies. Owing to the importance of these results for interpreting X-ray spectra, in an appendix we use simulated ASCA observations to examine in detail the ``Fe bias'' and ``Si bias'' associated with the spectral fitting of ellipticals, groups, and clusters of galaxies.

  3. X-ray Photoelectron Spectroscopy and Kinetic Study: Pt-Group Metals and Bimetallic Surfaces 

    E-Print Network [OSTI]

    Gath, Kerrie K.

    2010-01-14

    Pt-group metals were some of the first metals to be studied as catalysts for industrial use. The goal of these studies was to ascertain a fundamental understanding of CO oxidation and acetylene cyclotrimerization reactions ...

  4. X-ray Constraints on Galaxy-Gas-Jet Interactions in the Dumbbell Galaxies NGC4782 and NGC4783 in the LGG316 Group

    E-Print Network [OSTI]

    M. E. Machacek; R. P. Kraft; C. Jones; W. R. Forman; M. J. Hardcastle

    2007-04-30

    We present results from a 49.3 ks Chandra X-ray observation of the strongly interacting dumbbell galaxies NGC4782(3C278) and NGC4783 that constrain the kinematics of the interaction and models for bending the radio jets associated with NGC4782. The galaxies are embedded in an approximately spherical distribution of group gas, centered on NGC4782,that is nearly isothermal with mean kT ~ 1.4+/- 0.4 keV. The X-ray morphology suggests that NGC4783 is infalling into a single, massive galaxy group (LGG316) with NGC4782 nearly at rest at the center of the group potential.NGC4783 shows a sharp X-ray surface brightness edge (cold front) to the east and a ~15 kpc ram-pressure-stripped tail to the west. Analysis of this cold front indicates NGC4783 is moving east with a total velocity ~870+270-400 km/s (Mach ~1.4+0.5-0.7) at an inclination angle ~46 deg.(>33 deg.)towards us with respect to theplane of the sky. A ~45Myr old X-ray cavity, with enthalpy of 4.4 x 10^{57}ergs, coincides with the eastern radio lobe of 3C278. X-ray knots are found on both the radio jet and counter-jet, coincident with peaks in the radio emission. Assuming a light, mildly relativistic jet in 3C278, ram pressure velocities of 100-200 km/s impacting the eastern jet and ~170 km/s acting on the western radio lobe are sufficient to produce their observed bending. These velocities may be caused by bulk motions established in the IGM by the high velocity interaction between the galaxies, by the motion of NGC4782 relative to the IGM, or both.

  5. Chest x-Rays

    Broader source: Energy.gov [DOE]

    The B-reading is a special reading of a standard chest x-ray film performed by a physician certified by the National Institute for Occupational Safety and Health (NIOSH). The reading looks for changes on the chest x-ray that may indicate exposure and disease caused by agents such as asbestos or silica.

  6. X-ray beamsplitter

    DOE Patents [OSTI]

    Ceglio, Natale M. (Livermore, CA); Stearns, Daniel S. (Mountain View, CA); Hawryluk, Andrew M. (Modesto, CA); Barbee, Jr., Troy W. (Palo Alto, CA)

    1989-01-01

    An x-ray beamsplitter which splits an x-ray beam into two coherent parts by reflecting and transmitting some fraction of an incident beam has applications for x-ray interferometry, x-ray holography, x-ray beam manipulation, and x-ray laser cavity output couplers. The beamsplitter is formed of a wavelength selective multilayer thin film supported by a very thin x-ray transparent membrane. The beamsplitter resonantly transmits and reflects x-rays through thin film interference effects. A thin film is formed of 5-50 pairs of alternate Mo/Si layers with a period of 20-250 A. The support membrane is 10-200 nm of silicon nitride or boron nitride. The multilayer/support membrane structure is formed across a window in a substrate by first forming the structure on a solid substrate and then forming a window in the substrate to leave a free-standing structure over the window.

  7. X-ray beamsplitter

    DOE Patents [OSTI]

    Ceglio, N.M.; Stearns, D.G.; Hawryluk, A.M.; Barbee, T.W. Jr.

    1987-08-07

    An x-ray beamsplitter which splits an x-ray beam into two coherent parts by reflecting and transmitting some fraction of an incident beam has applications for x-ray interferometry, x-ray holography, x-ray beam manipulation, and x-ray laser cavity output couplers. The beamsplitter is formed of a wavelength selective multilayer thin film supported by a very thin x-ray transparent membrane. The beamsplitter resonantly transmits and reflects x-rays through thin film interference effects. A thin film is formed of 5--50 pairs of alternate Mo/Si layers with a period of 20--250 A. The support membrane is 10--200 nm of silicon nitride or boron nitride. The multilayer/support membrane structure is formed across a window in a substrate by first forming the structure on a solid substrate and then forming a window in the substrate to leave a free-standing structure over the window. 6 figs.

  8. X-ray laser

    DOE Patents [OSTI]

    Nilsen, Joseph (Livermore, CA)

    1991-01-01

    An X-ray laser (10) that lases between the K edges of carbon and oxygen, i.e. between 44 and 23 Angstroms, is provided. The laser comprises a silicon (12) and dysprosium (14) foil combination (16) that is driven by two beams (18, 20) of intense line focused (22, 24) optical laser radiation. Ground state nickel-like dysprosium ions (34) are resonantly photo-pumped to their upper X-ray laser state by line emission from hydrogen-like silicon ions (32). The novel X-ray laser should prove especially useful for the microscopy of biological specimens.

  9. X-ray Point Source Populations Constituting the Galactic Ridge X-ray Emission

    E-Print Network [OSTI]

    Morihana, Kumiko; Yoshida, Tessei; Ebisawa, Ken

    2013-01-01

    Apparently diffuse X-ray emission has been known to exist along the central quarter of the Galactic Plane since the beginning of the X-ray astronomy, which is referred to as the Galactic Ridge X-ray emission (GRXE). Recent deep X-ray observations have shown that numerous X-ray point sources account for a large fraction of the GRXE in the hard band (2-8 keV). However, the nature of these sources is poorly understood. Using the deepest X-ray observations made in the Chandra Bulge Field (Revnivtsev et al., 2009,2011), we present the result of a coherent photometric and spectroscopic analysis of individual X-ray point sources for the purpose of constraining their nature and deriving their fractional contributions to the hard band continuum and Fe K\\alpha line emission of the GRXE. Based on the X-ray color-color diagram, we divided the point sources into three groups: A (hard), B (soft and broad spectrum), and C (soft and peaked spectrum). The group A sources are further decomposed spectrally into thermal and non-...

  10. X-ray microtomography

    SciTech Connect (OSTI)

    Landis, Eric N.; Keane, Denis T.

    2010-12-15

    In this tutorial, we describe X-ray microtomography as a technique to nondestructively characterize material microstructure in three dimensions at a micron level spatial resolution. While commercially available laboratory scale instrumentation is available, we focus our attention on synchrotron-based systems, where we can exploit a high flux, monochromatic X-ray beam to produce high fidelity three-dimensional images. A brief description of the physics and the mathematical analysis behind the technique is followed by example applications to specific materials characterization problems, with a particular focus on the utilization of three-dimensional image processing that can be used to extract a wide range of useful information.

  11. Science with IUE and the Growth of an Astrophysical Group in Milan: from X-Ray Binaries to AGN

    E-Print Network [OSTI]

    Renato Falomo; Laura Maraschi; Elena Pian; Aldo Treves

    1998-11-16

    The contribution of an astrophysics group based in Milan to the science with the IUE satellite during its almost 20 years lifetime has focussed on high energy sources, of both galactic (LMXRB, HMXRB, and black hole candidates) and extragalactic (AGN) nature. The results of this long term research and in particular of the latest multiwavelength campaigns conducted simultaneously with IUE are reviewed here.

  12. Covalency Trends in Group IV Metallocene Dichlorides. Chlorine K-Edge X-Ray Absorption Spectroscopy And Time Dependent-Density Functional Theory

    SciTech Connect (OSTI)

    Kozimor, S.A.; Yang, P.; Batista, E.R.; Boland, K.S.; Burns, C.J.; Christensen, C.N.; Clark, D.L.; Conradson, S.D.; Hay, P.J.; Lezama, J.S.; Martin, R.L.; Schwarz, D.E.; Wilkerson, M.P.; Wolfsberg, L.E.

    2009-05-20

    For 3-5d transition-metal ions, the (C{sub 5}R{sub 5}){sub 2}MCl{sub 2} (R = H, Me for M = Ti, Zr, Hf) bent metallocenes represent a series of compounds that have been central in the development of organometallic chemistry and homogeneous catalysis. Here, we evaluate how changes in the principal quantum number for the group IV (C{sub 5}H{sub 5}){sub 2}MCl{sub 2} (M = Ti, Zr, Hf; 1-3, respectively) complexes affects the covalency of M-Cl bonds through application of Cl K-edge X-ray Absorption Spectroscopy (XAS). Spectra were recorded on solid samples dispersed as a thin film and encapsulated in polystyrene matrices to reliably minimize problems associated with X-ray self-absorption. The data show that XAS pre-edge intensities can be quantitatively reproduced when analytes are encapsulated in polystyrene. Cl K-edge XAS data show that covalency in M-Cl bonding changes in the order Ti > Zr > Hf and demonstrates that covalency slightly decreases with increasing principal quantum number in 1-3. The percent Cl 3p character was experimentally determined to be 26, 23, and 18% per M-Cl bond in the thin-film samples for 1-3 respectively and was indistinguishable from the polystyrene samples, which analyzed as 25, 25, and 19% for 1-3, respectively. To aid in interpretation of Cl K-edge XAS, 1-3 were also analyzed by ground-state and time-dependent density functional theory (TD-DFT) calculations. The calculated spectra and percent chlorine character are in close agreement with the experimental observations, and show 20, 18, and 17% Cl 3p character per M-Cl bond for 1-3, respectively. Polystyrene matrix encapsulation affords a convenient method to safely contain radioactive samples to extend our studies to include actinide elements, where both 5f and 6d orbitals are expected to play a role in M-Cl bonding and where transition assignments must rely on accurate theoretical calculations.

  13. Galaxies in X-ray Selected Clusters and Groups in Dark Energy Survey Data: Stellar Mass Growth of Bright Central Galaxies Since z~1.2

    E-Print Network [OSTI]

    Zhang, Y; Mckay, T; Rooney, P; Evrard, A E; Romer, A K; Perfecto, R; Song, J; Desai, S; Mohr, J; Wilcox, H; Bermeo, A; Jeltema, T; Hollowood, D; Bacon, D; Capozzi, D; Collins, C; Das, R; Gerdes, D; Hennig, C; Hilton, M; Hoyle, B; Kay, S; Liddle, A; Mann, R G; Mehrtens, N; Nichol, R C; Papovich, C; Sahlén, M; Soares-Santos, M; Stott, J; Viana, P T; Abbott, T; Abdalla, F B; Banerji, M; Bauer, A H; Benoit-Lévy, A; Bertin, E; Brooks, D; Buckley-Geer, E; Burke, D L; Rosell, A Carnero; Castander, F J; Diehl, H T; Doel, P; Cunha, C E; Eifler, T F; Neto, A Fausti; Fernandez, E; Flaugher, B; Fosalba, P; Frieman, J; Gaztanaga, E; Gruen, D; Gruendl, R A; Honscheid, K; James, D; Kuehn, K; Kuropatkin, N; Lahav, O; Maia, M A G; Makler, M; Marshall, J L; Martini, Paul; Miquel, R; Ogando, R; Plazas, A A; Roodman, A; Rykoff, E S; Sako, M; Sanchez, E; Scarpine, V; Schubnell, M; Sevilla, I; Smith, R C; Sobreira, F; Suchyta, E; Swanson, M E C; Tarle, G; Thaler, J; Tucker, D; Vikram, V; Da Costa, L N

    2015-01-01

    Using the science verification data of the Dark Energy Survey (DES) for a new sample of 106 X-Ray selected clusters and groups, we study the stellar mass growth of Bright Central Galaxies (BCGs) since redshift 1.2. Compared with the expectation in a semi-analytical model applied to the Millennium Simulation, the observed BCGs become under-massive/under-luminous with decreasing redshift. We incorporate the uncertainties associated with cluster mass, redshift, and BCG stellar mass measurements into analysis of a redshift-dependent BCG-cluster mass relation, $m_{*}\\propto(\\frac{M_{200}}{1.5\\times 10^{14}M_{\\odot}})^{0.24\\pm 0.08}(1+z)^{-0.19\\pm0.34}$, and compare the observed relation to the simulation prediction. We estimate the average growth rate since z = 1.0 for BCGs hosted by clusters of $M_{200, z}=10^{13.8}M_{\\odot}$, at $z=1.0$: $m_{*, BCG}$ appears to have grown by $0.13\\pm0.11$ dex, in tension at $\\sim 2.5 \\sigma$ significance level with the 0.4 dex growth rate expected in the simulation. We show that...

  14. X-Ray Data Booklet X-RAY DATA BOOKLET

    E-Print Network [OSTI]

    X-Ray Data Booklet X-RAY DATA BOOKLET Center for X-ray Optics and Advanced Light Source Lawrence Electromagnetic Relations Radioactivity and Radiation Protection Useful Formulas CXRO Home | ALS Home | LBL Home in PDF format Data Booklet Authors CXRO Home | ALS Home | LBL Home Privacy and Security Notice Please

  15. Fluctuation X-Ray Scattering

    SciTech Connect (OSTI)

    Saldin, PI: D. K.; Co-I's: J. C. H. Spence and P. Fromme

    2013-01-25

    The work supported by the grant was aimed at developing novel methods of finding the structures of biomolecules using x-rays from novel sources such as the x-ray free electron laser and modern synchrotrons

  16. Tunable X-ray source

    DOE Patents [OSTI]

    Boyce, James R. (Williamsburg, VA)

    2011-02-08

    A method for the production of X-ray bunches tunable in both time and energy level by generating multiple photon, X-ray, beams through the use of Thomson scattering. The method of the present invention simultaneously produces two X-ray pulses that are tunable in energy and/or time.

  17. X-RAY POINT-SOURCE POPULATIONS CONSTITUTING THE GALACTIC RIDGE X-RAY EMISSION

    SciTech Connect (OSTI)

    Morihana, Kumiko [Institute of Physical and Chemical Research (RIKEN), 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan)] [Institute of Physical and Chemical Research (RIKEN), 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Tsujimoto, Masahiro; Ebisawa, Ken [Japan Aerospace Exploration Agency, Institute of Space and Astronautical Science, 3-1-1 Yoshino-dai, Chuo-ku, Sagamihara, Kanagawa 252-5210 (Japan)] [Japan Aerospace Exploration Agency, Institute of Space and Astronautical Science, 3-1-1 Yoshino-dai, Chuo-ku, Sagamihara, Kanagawa 252-5210 (Japan); Yoshida, Tessei, E-mail: morihana@crab.riken.jp [National Astronomical Observatory of Japan, 2-21-1, Osawa, Mitaka, Tokyo 181-8588 (Japan)] [National Astronomical Observatory of Japan, 2-21-1, Osawa, Mitaka, Tokyo 181-8588 (Japan)

    2013-03-20

    Apparently diffuse X-ray emission has been known to exist along the central quarter of the Galactic Plane since the beginning of X-ray astronomy; this is referred to as the Galactic Ridge X-ray emission (GRXE). Recent deep X-ray observations have shown that numerous X-ray point sources account for a large fraction of the GRXE in the hard band (2-8 keV). However, the nature of these sources is poorly understood. Using the deepest X-ray observations made in the Chandra bulge field, we present the result of a coherent photometric and spectroscopic analysis of individual X-ray point sources for the purpose of constraining their nature and deriving their fractional contributions to the hard-band continuum and Fe K line emission of the GRXE. Based on the X-ray color-color diagram, we divided the point sources into three groups: A (hard), B (soft and broad spectrum), and C (soft and peaked spectrum). The group A sources are further decomposed spectrally into thermal and non-thermal sources with different fractions in different flux ranges. From their X-ray properties, we speculate that the group A non-thermal sources are mostly active galactic nuclei and the thermal sources are mostly white dwarf (WD) binaries such as magnetic and non-magnetic cataclysmic variables (CVs), pre-CVs, and symbiotic stars, whereas the group B and C sources are X-ray active stars in flares and quiescence, respectively. In the log N-log S curve of the 2-8 keV band, the group A non-thermal sources are dominant above Almost-Equal-To 10{sup -14} erg cm{sup -2} s{sup -1}, which is gradually taken over by Galactic sources in the fainter flux ranges. The Fe K{alpha} emission is mostly from the group A thermal (WD binaries) and the group B (X-ray active stars) sources.

  18. X-ray lithography source

    DOE Patents [OSTI]

    Piestrup, Melvin A. (Woodside, CA); Boyers, David G. (Mountain View, CA); Pincus, Cary (Sunnyvale, CA)

    1991-01-01

    A high-intensity, inexpensive X-ray source for X-ray lithography for the production of integrated circuits. Foil stacks are bombarded with a high-energy electron beam of 25 to 250 MeV to produce a flux of soft X-rays of 500 eV to 3 keV. Methods of increasing the total X-ray power and making the cross section of the X-ray beam uniform are described. Methods of obtaining the desired X-ray-beam field size, optimum frequency spectrum and elminating the neutron flux are all described. A method of obtaining a plurality of station operation is also described which makes the process more efficient and economical. The satisfying of these issues makes transition radiation an exellent moderate-priced X-ray source for lithography.

  19. X-Ray Cross-Complementing Group 1 and Thymidylate Synthase Polymorphisms Might Predict Response to Chemoradiotherapy in Rectal Cancer Patients

    SciTech Connect (OSTI)

    Lamas, Maria J.

    2012-01-01

    Purpose: 5-Fluorouracil-based chemoradiotherapy before total mesorectal excision is currently the standard treatment of Stage II and III rectal cancer patients. We used known predictive pharmacogenetic biomarkers to identify the responders to preoperative chemoradiotherapy in our series. Methods and Materials: A total of 93 Stage II-III rectal cancer patients were genotyped using peripheral blood samples. The genes analyzed were X-ray cross-complementing group 1 (XRCC1), ERCC1, MTHFR, EGFR, DPYD, and TYMS. The patients were treated with 225 mg/m{sup 2}/d continuous infusion of 5-fluorouracil concomitantly with radiotherapy (50.4 Gy) followed by total mesorectal excision. The outcomes were measured by tumor regression grade (TRG) as a major response (TRG 1 and TRG 2) or as a poor response (TRG3, TRG4, and TRG5). Results: The major histopathologic response rate was 47.3%. XRCC1 G/G carriers had a greater probability of response than G/A carriers (odds ratio, 4.18; 95% confidence interval, 1.62-10.74, p = .003) Patients with polymorphisms associated with high expression of thymidylate synthase (2R/3G, 3C/3G, and 3G/3G) showed a greater pathologic response rate compared with carriers of low expression (odds ratio, 2.65; 95% confidence interval, 1.10-6.39, p = .02) No significant differences were seen in the response according to EGFR, ERCC1, MTHFR{sub C}677 and MTHFR{sub A}1298 expression. Conclusions: XRCC1 G/G and thymidylate synthase (2R/3G, 3C/3G, and 3G/3G) are independent factors of a major response. Germline thymidylate synthase and XRCC1 polymorphisms might be useful as predictive markers of rectal tumor response to neoadjuvant chemoradiotherapy with 5-fluorouracil.

  20. X-Ray Diagnostics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired SolarAbout /Two0PhotosPresentationsWorld's largest singleX-Ray

  1. X-ray spectrometry

    SciTech Connect (OSTI)

    Markowicz, A.A.; Van Grieken, R.E.

    1986-04-01

    In the period under review, i.e, through 1984 and 1985, some 600 articles on XRS (X-ray spectrometry) were published; most of these have been scanned and the most fundamental ones are discussed. All references will refer to English-language articles, unless states otherwise. Also general books have appeared on quantitative EPXMA (electron-probe X-ray microanalysis) and analytical electron microscopy (AEM) as well as an extensive review on the application of XRS to trace analysis of environmental samples. In the period under review no radically new developments have been seen in XRS. However, significant improvements have been made. Gain in intensities has been achieved by more efficient excitation, higher reflectivity of dispersing media, and better geometry. Better understanding of the physical process of photon- and electron-specimen interactions led to complex but more accurate equations for correction of various interelement effects. Extensive use of micro- and minicomputers now enables fully automatic operation, including qualitative analysis. However, sample preparation and presentation still put a limit to further progress. Although some authors find XRS in the phase of stabilization or even stagnation, further gradual developments are expected, particularly toward more dedicated equipment, advanced automation, and image analysis systems. Ways are outlined in which XRS has been improved in the 2 last years by excitation, detection, instrumental, methodological, and theoretical advances. 340 references.

  2. Miniature x-ray source

    DOE Patents [OSTI]

    Trebes, James E. (Livermore, CA); Stone, Gary F. (Livermore, CA); Bell, Perry M. (Tracy, CA); Robinson, Ronald B. (Modesto, CA); Chornenky, Victor I. (Minnetonka, MN)

    2002-01-01

    A miniature x-ray source capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature x-ray source comprises a compact vacuum tube assembly containing a cathode, an anode, a high voltage feedthru for delivering high voltage to the anode, a getter for maintaining high vacuum, a connection for an initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is highly x-ray transparent and made, for example, from boron nitride. The compact size and potential for remote operation allows the x-ray source, for example, to be placed adjacent to a material sample undergoing analysis or in proximity to the region to be treated for medical applications.

  3. X-ray shearing interferometer

    DOE Patents [OSTI]

    Koch, Jeffrey A. (Livermore, CA)

    2003-07-08

    An x-ray interferometer for analyzing high density plasmas and optically opaque materials includes a point-like x-ray source for providing a broadband x-ray source. The x-rays are directed through a target material and then are reflected by a high-quality ellipsoidally-bent imaging crystal to a diffraction grating disposed at 1.times. magnification. A spherically-bent imaging crystal is employed when the x-rays that are incident on the crystal surface are normal to that surface. The diffraction grating produces multiple beams which interfere with one another to produce an interference pattern which contains information about the target. A detector is disposed at the position of the image of the target produced by the interfering beams.

  4. X-ray fluorescence mapping

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWindX-RayX-Ray ScienceX-Ray

  5. Center for X-Ray Optics, 1992

    SciTech Connect (OSTI)

    Not Available

    1993-08-01

    This report discusses the following topics: Center for X-Ray Optics; Soft X-Ray Imaging wit Zone Plate Lenses; Biological X-Ray microscopy; Extreme Ultraviolet Lithography for Nanoelectronic Pattern Transfer; Multilayer Reflective Optics; EUV/Soft X-ray Reflectometer; Photoemission Microscopy with Reflective Optics; Spectroscopy with Soft X-Rays; Hard X-Ray Microprobe; Coronary Angiography; and Atomic Scattering Factors.

  6. Miniature x-ray source

    DOE Patents [OSTI]

    Trebes, James E. (Livermore, CA); Bell, Perry M. (Tracy, CA); Robinson, Ronald B. (Modesto, CA)

    2000-01-01

    A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

  7. Ultrafast X-ray Sources

    SciTech Connect (OSTI)

    George Neil

    2010-04-19

    Since before the scattering of X-rays off of DNA led to the first understanding of the double helix structure, sources of X-rays have been an essential tool for scientists examining the structure and interactions of matter. The resolution of a microscope is proportional to the wavelength of light so x-rays can see much finer structures than visible light, down to single atoms. In addition, the energy of X-rays is resonant with the core atomic levels of atoms so with appropriate wavelengths the placement of specific atoms in a large molecule can be determined. Over 10,000 scientists use synchrotron sources, storage rings of high energy electrons, each year worldwide. As an example of such use, virtually every picture of a protein or drug molecule that one sees in the scientific press is a reconstruction based on X-ray scattering of synchrotron light from the crystallized form of that molecule. Unfortunately those pictures are static and proteins work through configuration (shape) changes in response to energy transfer. To understand how biological systems work requires following the energy flow to these molecules and tracking how shape changes drive their interaction with other molecules. We'd like to be able to freeze the action of these molecules at various steps along the way with an X-ray strobe light. How fast does it have to be? To actually get a picture of a molecule in a fixed configuration requires X-ray pulses as short as 30 femtoseconds (1/30 of a millionth of a millionth of a second). To capture the energy flow through changes in electronic levels requires a faster strobe, less than 1 femtosecond! And to acquire such information in smaller samples with higher accuracy demands brighter and brighter X-rays. Unfortunately modern synchrotrons (dubbed 3rd Generation Light Sources) cannot deliver such short bright pulses of X-rays. An entirely new approach is required, linear-accelerator (linac-)-based light sources termed 4th or Next Generation Light Sources (NGLSs). Although NGLSs will not displace synchrotrons from their role they do offer exciting new capabilities which can be understood from the physics of the light production in each device.

  8. Compact x-ray source and panel

    DOE Patents [OSTI]

    Sampayon, Stephen E. (Manteca, CA)

    2008-02-12

    A compact, self-contained x-ray source, and a compact x-ray source panel having a plurality of such x-ray sources arranged in a preferably broad-area pixelized array. Each x-ray source includes an electron source for producing an electron beam, an x-ray conversion target, and a multilayer insulator separating the electron source and the x-ray conversion target from each other. The multi-layer insulator preferably has a cylindrical configuration with a plurality of alternating insulator and conductor layers surrounding an acceleration channel leading from the electron source to the x-ray conversion target. A power source is connected to each x-ray source of the array to produce an accelerating gradient between the electron source and x-ray conversion target in any one or more of the x-ray sources independent of other x-ray sources in the array, so as to accelerate an electron beam towards the x-ray conversion target. The multilayer insulator enables relatively short separation distances between the electron source and the x-ray conversion target so that a thin panel is possible for compactness. This is due to the ability of the plurality of alternating insulator and conductor layers of the multilayer insulators to resist surface flashover when sufficiently high acceleration energies necessary for x-ray generation are supplied by the power source to the x-ray sources.

  9. Focused X-ray source

    DOE Patents [OSTI]

    Piestrup, Melvin A. (Woodside, CA); Boyers, David G. (Mountain View, CA); Pincus, Cary I. (Sunnyvale, CA); Maccagno, Pierre (Stanford, CA)

    1990-01-01

    An intense, relatively inexpensive X-ray source (as compared to a synchrotron emitter) for technological, scientific, and spectroscopic purposes. A conical radiation pattern produced by a single foil or stack of foils is focused by optics to increase the intensity of the radiation at a distance from the conical radiator.

  10. Soft X-ray microflares

    E-Print Network [OSTI]

    Mirzoeva, I K

    2015-01-01

    Soft X-ray solar bursts are studied. Weak bursts with powers up to 10-8 W/m2 were detected. All the events were confirmed by GOES observations. Parameters of these microflares are determined. A physical mechanism for the low-intensity solar events is discussed.

  11. Focused X-ray source

    DOE Patents [OSTI]

    Piestrup, M.A.; Boyers, D.G.; Pincus, C.I.; Maccagno, P.

    1990-08-21

    Disclosed is an intense, relatively inexpensive X-ray source (as compared to a synchrotron emitter) for technological, scientific, and spectroscopic purposes. A conical radiation pattern produced by a single foil or stack of foils is focused by optics to increase the intensity of the radiation at a distance from the conical radiator. 8 figs.

  12. ASD Groups | Advanced Photon Source

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room News Publications Traditional Knowledge Kiosks Barrow,ARM: Three Meterhighlights/

  13. X-ray Selected Clusters of Galaxies

    E-Print Network [OSTI]

    Isabella M. Gioia

    1996-01-21

    This paper given at the meeting on "Mapping, Measuring and Modelling the Universe" presents three topics: 1) the study of the clusters and groups of galaxies found serendipitously in the North Ecliptic Pole (NEP) region of the ROSAT all-sky survey; 2) the highest redshift clusters found in the EMSS (up to z=0.82) and the cosmological implications of their very existence; 3) the gravitational lensing in the EMSS X-ray selected clusters of galaxies observed by the Hubble Space Telescope.

  14. Producing X-rays at the APS

    ScienceCinema (OSTI)

    None

    2013-04-19

    An introduction and overview of the Advanced Photon Source at Argonne National Laboratory, the technology that produces the brightest X-ray beams in the Western Hemisphere, and the research carried out by scientists using those X-rays.

  15. Microgap x-ray detector

    DOE Patents [OSTI]

    Wuest, Craig R. (Danville, CA); Bionta, Richard M. (Livermore, CA); Ables, Elden (Livermore, CA)

    1994-01-01

    An x-ray detector which provides for the conversion of x-ray photons into photoelectrons and subsequent amplification of these photoelectrons through the generation of electron avalanches in a thin gas-filled region subject to a high electric potential. The detector comprises a cathode (photocathode) and an anode separated by the thin, gas-filled region. The cathode may comprise a substrate, such a beryllium, coated with a layer of high atomic number material, such as gold, while the anode can be a single conducting plane of material, such as gold, or a plane of resistive material, such as chromium/silicon monoxide, or multiple areas of conductive or resistive material, mounted on a substrate composed of glass, plastic or ceramic. The charge collected from each electron avalanche by the anode is passed through processing electronics to a point of use, such as an oscilloscope.

  16. Microgap x-ray detector

    DOE Patents [OSTI]

    Wuest, C.R.; Bionta, R.M.; Ables, E.

    1994-05-03

    An x-ray detector is disclosed which provides for the conversion of x-ray photons into photoelectrons and subsequent amplification of these photoelectrons through the generation of electron avalanches in a thin gas-filled region subject to a high electric potential. The detector comprises a cathode (photocathode) and an anode separated by the thin, gas-filled region. The cathode may comprise a substrate, such a beryllium, coated with a layer of high atomic number material, such as gold, while the anode can be a single conducting plane of material, such as gold, or a plane of resistive material, such as chromium/silicon monoxide, or multiple areas of conductive or resistive material, mounted on a substrate composed of glass, plastic or ceramic. The charge collected from each electron avalanche by the anode is passed through processing electronics to a point of use, such as an oscilloscope. 3 figures.

  17. Phase-sensitive X-ray imager

    DOE Patents [OSTI]

    Baker, Kevin Louis

    2013-01-08

    X-ray phase sensitive wave-front sensor techniques are detailed that are capable of measuring the entire two-dimensional x-ray electric field, both the amplitude and phase, with a single measurement. These Hartmann sensing and 2-D Shear interferometry wave-front sensors do not require a temporally coherent source and are therefore compatible with x-ray tubes and also with laser-produced or x-pinch x-ray sources.

  18. X-ray and Near-infrared Studies of a Star-forming Cloud; L1448

    E-Print Network [OSTI]

    Tsujimoto, M; Tsuboi, Y

    2005-01-01

    We present the results of X-ray and near-infrared (NIR) observations of L1448, a star-forming region in the Perseus cloud complex using the Chandra X-ray Observatory and the 4 m telescope at the Kitt Peak National Observatory. We detect 72 X-ray sources in a ~17 arcmin x 17 arcmin region with a ~68 ks ACIS exposure, for which we conduct follow-up NIR imaging observations in a concentric ~11 arcmin x 11 arcmin region with FLAMINGOS down to m_Ks ~ 17 mag. Twelve X-ray sources have NIR or optical counterparts. By plotting X-ray mean energy versus NIR to X-ray flux ratio, the X-ray sources are clearly separated into two groups. The X-ray spectral and temporal features as well as NIR magnitudes and colors indicate that one group mainly consists of young stellar objects (YSOs) in the cloud and the other of background extragalactic sources. Ten X-ray-emitting YSO candidates are thus newly identified, which are low-mass or brown dwarf mass sources from their NIR magnitudes. In addition, a possible X-ray signal is fou...

  19. X-ray and Near-infrared Studies of a Star-forming Cloud; L1448

    E-Print Network [OSTI]

    M. Tsujimoto; N. Kobayashi; Y. Tsuboi

    2005-06-27

    We present the results of X-ray and near-infrared (NIR) observations of L1448, a star-forming region in the Perseus cloud complex using the Chandra X-ray Observatory and the 4 m telescope at the Kitt Peak National Observatory. We detect 72 X-ray sources in a ~17 arcmin x 17 arcmin region with a ~68 ks ACIS exposure, for which we conduct follow-up NIR imaging observations in a concentric ~11 arcmin x 11 arcmin region with FLAMINGOS down to m_Ks ~ 17 mag. Twelve X-ray sources have NIR or optical counterparts. By plotting X-ray mean energy versus NIR to X-ray flux ratio, the X-ray sources are clearly separated into two groups. The X-ray spectral and temporal features as well as NIR magnitudes and colors indicate that one group mainly consists of young stellar objects (YSOs) in the cloud and the other of background extragalactic sources. Ten X-ray-emitting YSO candidates are thus newly identified, which are low-mass or brown dwarf mass sources from their NIR magnitudes. In addition, a possible X-ray signal is found from a mid-infrared protostar L1448 IRS 3(A). The lack of detection of this source in our deep NIR images indicates that this source has a very steep spectral slope of > 3.2 in 2--10 micron.

  20. Confusion of Diffuse Objects in the X-ray Sky

    E-Print Network [OSTI]

    G. Mark Voit; August E. Evrard; Greg L. Bryan

    2000-12-08

    Most of the baryons in the present-day universe are thought to reside in intergalactic space at temperatures of 10^5-10^7 K. X-ray emission from these baryons contributes a modest (~10%) fraction of the ~ 1 keV background whose prominence within the large-scale cosmic web depends on the amount of non-gravitational energy injected into intergalactic space by supernovae and AGNs. Here we show that the virialized regions of groups and clusters cover over a third of the sky, creating a source-confusion problem that may hinder X-ray searches for individual intercluster filaments and contaminate observations of distant groups.

  1. X-ray emission from O stars

    E-Print Network [OSTI]

    David H. Cohen

    2008-02-01

    Young O stars are strong, hard, and variable X-ray sources, properties which strongly affect their circumstellar and galactic environments. After ~1 Myr, these stars settle down to become steady sources of soft X-rays. I use high-resolution X-ray spectroscopy and MHD modeling to show that young O stars like theta-1 Ori C are well explained by the magnetically channeled wind shock scenario. After their magnetic fields dissipate, older O stars produce X-rays via shock heating in their unstable stellar winds. Here too I use X-ray spectroscopy and numerical modeling to confirm this scenario. In addition to elucidating the nature and cause of the O star X-ray emission, modeling of the high-resolution X-ray spectra of O supergiants provides strong evidence that mass-loss rates of these O stars have been overestimated.

  2. X-ray Imaging Workshop

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWindX-Ray ImagingInImaging and

  3. Soft X-ray techniques to study mesoscale magnetism

    E-Print Network [OSTI]

    Kortright, Jeffrey B.

    2003-01-01

    X-Ray Techniques to Study Mesoscale Magnetism Jeffrey B.X-Ray Techniques to Study Mesoscale Magnetism Jeffrey B.

  4. X-ray Observations of Mrk 231

    E-Print Network [OSTI]

    T. J. Turner

    1998-08-10

    This paper presents new X-ray observations of Mrk 231, an active galaxy of particular interest due to its large infrared luminosity and the presence of several blueshifted broad absorption line (BAL) systems, a phenomenon observed in a small fraction of QSOs. A ROSAT HRI image of Mrk 231 is presented, this shows an extended region of soft X-ray emission, covering several tens of kpc, consistent with the extent of the host galaxy. An ASCA observation of Mrk 231 is also presented. Hard X-rays are detected but the data show no significant variability in X-ray flux. The hard X-ray continuum is heavily attenuated and X-ray column estimates range from ~ 2 x 10^{22} - 10^{23} cm^{-2} depending on whether the material is assumed to be neutral or ionized, and on the model assumed for the extended X-ray component. These ASCA data provide only the second hard X-ray spectrum of a BAL AGN presented to date. The broad-band spectral-energy-distribution of the source is discussed. While Mrk 231 is X-ray weak compared to Seyfert 1 galaxies, it has an optical-to-X-ray spectrum typical of a QSO.

  5. Controlling X-rays With Light

    SciTech Connect (OSTI)

    Glover, Ernie; Hertlein, Marcus; Southworth, Steve; Allison, Tom; van Tilborg, Jeroen; Kanter, Elliot; Krassig, B.; Varma, H.; Rude, Bruce; Santra, Robin; Belkacem, Ali; Young, Linda

    2010-08-02

    Ultrafast x-ray science is an exciting frontier that promises the visualization of electronic, atomic and molecular dynamics on atomic time and length scales. A largelyunexplored area of ultrafast x-ray science is the use of light to control how x-rays interact with matter. In order to extend control concepts established for long wavelengthprobes to the x-ray regime, the optical control field must drive a coherent electronic response on a timescale comparable to femtosecond core-hole lifetimes. An intense field is required to achieve this rapid response. Here an intense optical control pulse isobserved to efficiently modulate photoelectric absorption for x-rays and to create an ultrafast transparency window. We demonstrate an application of x-ray transparencyrelevant to ultrafast x-ray sources: an all-photonic temporal cross-correlation measurement of a femtosecond x-ray pulse. The ability to control x-ray/matterinteractions with light will create new opportunities at current and next-generation x-ray light sources.

  6. X-ray transmissive debris shield

    DOE Patents [OSTI]

    Spielman, Rick B. (Albuquerque, NM)

    1994-01-01

    A composite window structure is described for transmitting x-ray radiation and for shielding radiation generated debris. In particular, separate layers of different x-ray transmissive materials are laminated together to form a high strength, x-ray transmissive debris shield which is particularly suited for use in high energy fluences. In one embodiment, the composite window comprises alternating layers of beryllium and a thermoset polymer.

  7. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Miaja-Avila, L.; O'Neil, G. C.; Uhlig, J.; Cromer, C. L.; Dowell, M. L.; Jimenez, R.; Hoover, A. S.; Silverman, K. L.; Ullom, J. N.

    2015-03-02

    We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 ?m FWHM x-ray spot size, containing ~106 photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >107 laser pulses, we also presentmore »data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.« less

  8. X-ray microscopy. Beyond ensemble averages

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Ice, Gene E.; Budai, John D.

    2015-06-23

    This work exemplifies emerging tools to characterize local materials structure and dynamics, made possible by powerful X-ray synchrotron and transmission electron microscopy methods.

  9. X-ray laser microscope apparatus

    DOE Patents [OSTI]

    Suckewer, Szymon (Princeton, NJ); DiCicco, Darrell S. (Plainsboro, NJ); Hirschberg, Joseph G. (Coral Gables, FL); Meixler, Lewis D. (East Windsor, NJ); Sathre, Robert (Princeton, NJ); Skinner, Charles H. (Lawrenceville, NJ)

    1990-01-01

    A microscope consisting of an x-ray contact microscope and an optical microscope. The optical, phase contrast, microscope is used to align a target with respect to a source of soft x-rays. The source of soft x-rays preferably comprises an x-ray laser but could comprise a synchrotron or other pulse source of x-rays. Transparent resist material is used to support the target. The optical microscope is located on the opposite side of the transparent resist material from the target and is employed to align the target with respect to the anticipated soft x-ray laser beam. After alignment with the use of the optical microscope, the target is exposed to the soft x-ray laser beam. The x-ray sensitive transparent resist material whose chemical bonds are altered by the x-ray beam passing through the target mater GOVERNMENT LICENSE RIGHTS This invention was made with government support under Contract No. De-FG02-86ER13609 awarded by the Department of Energy. The Government has certain rights in this invention.

  10. Compound refractive X-ray lens

    DOE Patents [OSTI]

    Nygren, David R. (Berkeley, CA); Cahn, Robert (Walnut Creek, CA); Cederstrom, Bjorn (Traellborg, SE); Danielsson, Mats (Stocksund, SE); Vestlund, Jonas (Stockholm, SE)

    2000-01-01

    An apparatus and method for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point.

  11. X-Ray Nanoimaging: Instruments and Methods

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired SolarAbout /Two0PhotosPresentationsWorld's largestX-RayX-RayX-RayX-Ray

  12. X-ray spectroscopy of neutron star low-mass X-ray binaries

    E-Print Network [OSTI]

    Krauss, Miriam Ilana

    2007-01-01

    In this thesis, I present work spanning a variety of topics relating to neutron star lowmass X-ray binaries (LMXBs) and utilize spectral information from X-ray observations to further our understanding of these sources. ...

  13. Phased Contrast X-Ray Imaging

    ScienceCinema (OSTI)

    Erin Miller

    2012-12-31

    The Pacific Northwest National Laboratory is developing a range of technologies to broaden the field of explosives detection. Phased contrast X-ray imaging, which uses silicon gratings to detect distortions in the X-ray wave front, may be applicable to mail or luggage scanning for explosives; it can also be used in detecting other contraband, small-parts inspection, or materials characterization.

  14. X-rays from Hot Subdwarfs

    E-Print Network [OSTI]

    Mereghetti, Sandro

    2015-01-01

    Thanks to the high sensitivity of the instruments on board the XMM-Newton and Chandra satellites, it has become possible to explore the properties of the X-ray emission from hot subdwarfs. The small but growing sample of hot subdwarfs detected in X-rays includes binary systems, in which the X-rays result from wind accretion onto a compact companion (white dwarf or neutron star), as well as isolated sdO stars in which X-rays are probably due to shock instabilities in the wind. X-ray observations of these low mass stars provide information which can be useful also for our understanding of the winds of more luminous and massive early-type stars and can lead to the discovery of particularly interesting binary systems.

  15. High Energy Vision: Processing X-rays

    E-Print Network [OSTI]

    DePasquale, Joseph; Edmonds, Peter

    2015-01-01

    Astronomy is by nature a visual science. The high quality imagery produced by the world's observatories can be a key to effectively engaging with the public and helping to inspire the next generation of scientists. Creating compelling astronomical imagery can, however, be particularly challenging in the non-optical wavelength regimes. In the case of X-ray astronomy, where the amount of light available to create an image is severely limited, it is necessary to employ sophisticated image processing algorithms to translate light beyond human vision into imagery that is aesthetically pleasing while still being scientifically accurate. This paper provides a brief overview of the history of X-ray astronomy leading to the deployment of NASA's Chandra X-ray Observatory, followed by an examination of the specific challenges posed by processing X-ray imagery. The authors then explore image processing techniques used to mitigate such processing challenges in order to create effective public imagery for X-ray astronomy. ...

  16. X-ray crystal structure and small-angle X-ray scattering of sheep liver sorbitol dehydrogenase

    SciTech Connect (OSTI)

    Yennawar, Hemant [Pennsylvania State University, 8 Althouse Laboratory, University Park, PA 16802 (United States); Møller, Magda [Cornell High Energy Synchrotron Source, Ithaca, NY 14853 (United States); University of Copenhagen, DK-2100 Copenhagen (Denmark); Gillilan, Richard [Cornell High Energy Synchrotron Source, Ithaca, NY 14853 (United States); Yennawar, Neela, E-mail: nhy1@psu.edu [Pennsylvania State University, 8 Althouse Laboratory, University Park, PA 16802 (United States)

    2011-05-01

    The X-ray crystal structure and a small-angle X-ray scattering solution structure of sheep liver sorbitol dehydrogenase have been determined. The details of the interactions that enable the tetramer scaffold to be the functional biological unit have been analyzed. The X-ray crystal structure of sheep liver sorbitol dehydrogenase (slSDH) has been determined using the crystal structure of human sorbitol dehydrogenase (hSDH) as a molecular-replacement model. slSDH crystallized in space group I222 with one monomer in the asymmetric unit. A conserved tetramer that superposes well with that seen in hSDH (despite belonging to a different space group) and obeying the 222 crystal symmetry is seen in slSDH. An acetate molecule is bound in the active site, coordinating to the active-site zinc through a water molecule. Glycerol, a substrate of slSDH, also occupies the substrate-binding pocket together with the acetate designed by nature to fit large polyol substrates. The substrate-binding pocket is seen to be in close proximity to the tetramer interface, which explains the need for the structural integrity of the tetramer for enzyme activity. Small-angle X-ray scattering was also used to identify the quaternary structure of the tetramer of slSDH in solution.

  17. X-ray phase-contrast methods

    SciTech Connect (OSTI)

    Lider, V. V., E-mail: lider@ns.crys.ras.ru; Kovalchuk, M. V. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)] [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2013-11-15

    This review is devoted to a comparative description of the methods for forming X-ray phase-contrast images of weakly absorbing (phase) objects. These include the crystal interferometer method, the Talbot interferometer method, diffraction-enhanced X-ray imaging, and the in-line method. The potential of their practical application in various fields of science and technology is discussed. The publications on the development and optimization of X-ray phase-contrast methods and the experimental study of phase objects are analyzed.

  18. X-rays Illuminate Ancient Archimedes Text

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWindX-RayX-RayX-ray

  19. Small Angle X-Ray Scattering Detector

    DOE Patents [OSTI]

    Hessler, Jan P.

    2004-06-15

    A detector for time-resolved small-angle x-ray scattering includes a nearly constant diameter, evacuated linear tube having an end plate detector with a first fluorescent screen and concentric rings of first fiber optic bundles for low angle scattering detection and an annular detector having a second fluorescent screen and second fiber optic bundles concentrically disposed about the tube for higher angle scattering detection. With the scattering source, i.e., the specimen under investigation, located outside of the evacuated tube on the tube's longitudinal axis, scattered x-rays are detected by the fiber optic bundles, to each of which is coupled a respective photodetector, to provide a measurement resolution, i.e., dq/q, where q is the momentum transferred from an incident x-ray to an x-ray scattering specimen, of 2% over two (2) orders of magnitude in reciprocal space, i.e., qmax/qmin approx=lO0.

  20. X-Ray Nanoimaging: Instruments and Methods

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Instruments and Methods X-Ray Nanoimaging: Instruments and Methods Print To be held as part of SPIE. http:spie.orgOP318 August 28-29, 2013; San Diego, California, USA...

  1. X-ray source for mammography

    DOE Patents [OSTI]

    Logan, Clinton M. (Pleasanton, CA)

    1994-01-01

    An x-ray source utilizing anode material which shifts the output spectrum to higher energy and thereby obtains higher penetrating ability for screening mammography application, than the currently utilized anode material. The currently used anode material (molybdenum) produces an energy x-ray spectrum of 17.5/19.6 keV, which using the anode material of this invention (e.g. silver, rhodium, and tungsten) the x-ray spectrum would be in the 20-35 keV region. Thus, the anode material of this invention provides for imaging of breasts with higher than average x-ray opacity without increase of the radiation dose, and thus reduces the risk of induced breast cancer due to the radiation dose administered for mammograms.

  2. X-ray source for mammography

    DOE Patents [OSTI]

    Logan, C.M.

    1994-12-20

    An x-ray source is described utilizing anode material which shifts the output spectrum to higher energy and thereby obtains higher penetrating ability for screening mammography application, than the currently utilized anode material. The currently used anode material (molybdenum) produces an energy x-ray spectrum of 17.5/19.6 keV, which using the anode material of this invention (e.g. silver, rhodium, and tungsten) the x-ray spectrum would be in the 20-35 keV region. Thus, the anode material of this invention provides for imaging of breasts with higher than average x-ray opacity without increase of the radiation dose, and thus reduces the risk of induced breast cancer due to the radiation dose administered for mammograms. 6 figures.

  3. Compton backscattered collmated X-ray source

    DOE Patents [OSTI]

    Ruth, Ronald D. (Woodside, CA); Huang, Zhirong (Stanford, CA)

    2000-01-01

    A high-intensity, inexpensive and collimated x-ray source for applications such as x-ray lithography is disclosed. An intense pulse from a high power laser, stored in a high-finesse resonator, repetitively collides nearly head-on with and Compton backscatters off a bunched electron beam, having relatively low energy and circulating in a compact storage ring. Both the laser and the electron beams are tightly focused and matched at the interaction region inside the optical resonator. The laser-electron interaction not only gives rise to x-rays at the desired wavelength, but also cools and stabilizes the electrons against intrabeam scattering and Coulomb repulsion with each other in the storage ring. This cooling provides a compact, intense bunch of electrons suitable for many applications. In particular, a sufficient amount of x-rays can be generated by this device to make it an excellent and flexible Compton backscattered x-ray (CBX) source for high throughput x-ray lithography and many other applications.

  4. Compton backscattered collimated x-ray source

    DOE Patents [OSTI]

    Ruth, R.D.; Huang, Z.

    1998-10-20

    A high-intensity, inexpensive and collimated x-ray source is disclosed for applications such as x-ray lithography is disclosed. An intense pulse from a high power laser, stored in a high-finesse resonator, repetitively collides nearly head-on with and Compton backscatters off a bunched electron beam, having relatively low energy and circulating in a compact storage ring. Both the laser and the electron beams are tightly focused and matched at the interaction region inside the optical resonator. The laser-electron interaction not only gives rise to x-rays at the desired wavelength, but also cools and stabilizes the electrons against intrabeam scattering and Coulomb repulsion with each other in the storage ring. This cooling provides a compact, intense bunch of electrons suitable for many applications. In particular, a sufficient amount of x-rays can be generated by this device to make it an excellent and flexible Compton backscattered x-ray (CBX) source for high throughput x-ray lithography and many other applications. 4 figs.

  5. Compton backscattered collimated x-ray source

    DOE Patents [OSTI]

    Ruth, Ronald D. (Woodside, CA); Huang, Zhirong (Stanford, CA)

    1998-01-01

    A high-intensity, inexpensive and collimated x-ray source for applications such as x-ray lithography is disclosed. An intense pulse from a high power laser, stored in a high-finesse resonator, repetitively collides nearly head-on with and Compton backscatters off a bunched electron beam, having relatively low energy and circulating in a compact storage ring. Both the laser and the electron beams are tightly focused and matched at the interaction region inside the optical resonator. The laser-electron interaction not only gives rise to x-rays at the desired wavelength, but also cools and stabilizes the electrons against intrabeam scattering and Coulomb repulsion with each other in the storage ring. This cooling provides a compact, intense bunch of electrons suitable for many applications. In particular, a sufficient amount of x-rays can be generated by this device to make it an excellent and flexible Compton backscattered x-ray (CBX) source for high throughput x-ray lithography and many other applications.

  6. X-ray laser driven gold targets

    SciTech Connect (OSTI)

    Petrova, Tz. B., E-mail: lina.petrova@nrl.navy.mil; Whitney, K. G.; Davis, J. [Plasma Physics Division, Naval Research Laboratory, 4555 Overlook Ave. SW, Washington, DC 20375 (United States)] [Plasma Physics Division, Naval Research Laboratory, 4555 Overlook Ave. SW, Washington, DC 20375 (United States)

    2014-03-15

    The femtosecond population dynamics of gold irradiated by a coherent high-intensity (>10{sup 17}?W/cm{sup 2}) x-ray laser pulse is investigated theoretically. There are two aspects to the assembled model. One is the construction of a detailed model of platinum-like gold inclusive of all inner-shell states that are created by photoionization of atomic gold and decay either by radiative or Auger processes. Second is the computation of the population dynamics that ensues when an x-ray pulse is absorbed in gold. The hole state generation depends on the intensity and wavelength of the driving x-ray pulse. The excited state populations reached during a few femtosecond timescales are high enough to generate population inversions, whose gain coefficients are calculated. These amplified lines in the emitted x-ray spectrum provide important diagnostics of the radiation dynamics and also suggest a nonlinear way to increase the frequency of the coherent output x-ray pulses relative to the frequency of the driver input x-ray pulse.

  7. Transient x-ray diffraction and its application to materials science and x-ray optics

    SciTech Connect (OSTI)

    Hauer, A.A.; Kopp, R.; Cobble, J.; Kyrala, G.; Springer, R.

    1997-12-01

    Time resolved x-ray diffraction and scattering have been applied to the measurement of a wide variety of physical phenomena from chemical reactions to shock wave physics. Interest in this method has heightened in recent years with the advent of versatile, high power, pulsed x-ray sources utilizing laser plasmas, electron beams and other methods. In this article, we will describe some of the fundamentals involved in time resolved x-ray diffraction, review some of the history of its development, and describe some recent progress in the field. In this article we will emphasize the use of laser-plasmas as the x-ray source for transient diffraction.

  8. Power Systems Group Home Page

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Systems Division Search APS ... Search Button About ASD General Information ASD Groups ESHQA Operations Argonne Home > Advanced Photon Source > Power Systems Group This page is...

  9. Differential phase contrast X-ray imaging system and components

    DOE Patents [OSTI]

    Stutman, Daniel; Finkenthal, Michael

    2014-07-01

    A differential phase contrast X-ray imaging system includes an X-ray illumination system, a beam splitter arranged in an optical path of the X-ray illumination system, and a detection system arranged in an optical path to detect X-rays after passing through the beam splitter.

  10. Pyroelectric crystal-based X-ray diffractometer

    E-Print Network [OSTI]

    Fernandes, Louis Edward

    2007-01-01

    We investigate the use of an Amptek Cool-X X-ray Generator for an instructional tool in the physics of x-rays, as well as a source for x-rays for crystal diffraction experiments. The x-ray source is a solid-state two-phase ...

  11. Ultrafast X-Ray Coherent Control

    SciTech Connect (OSTI)

    Reis, David

    2009-05-01

    This main purpose of this grant was to develop the nascent #12;eld of ultrafast x-ray science using accelerator-based sources, and originally developed from an idea that a laser could modulate the di#11;racting properties of a x-ray di#11;racting crystal on a fast enough time scale to switch out in time a shorter slice from the already short x-ray pulses from a synchrotron. The research was carried out primarily at the Advanced Photon Source (APS) sector 7 at Argonne National Laboratory and the Sub-Picosecond Pulse Source (SPPS) at SLAC; in anticipation of the Linac Coherent Light Source (LCLS) x-ray free electron laser that became operational in 2009 at SLAC (all National User Facilities operated by BES). The research centered on the generation, control and measurement of atomic-scale dynamics in atomic, molecular optical and condensed matter systems with temporal and spatial resolution . It helped develop the ultrafast physics, techniques and scienti#12;c case for using the unprecedented characteristics of the LCLS. The project has been very successful with results have been disseminated widely and in top journals, have been well cited in the #12;eld, and have laid the foundation for many experiments being performed on the LCLS, the world's #12;rst hard x-ray free electron laser.

  12. Oscillations During Thermonuclear X-ray Bursts

    E-Print Network [OSTI]

    Tod E. Strohmayer

    2001-01-12

    High amplitude, nearly coherent X-ray brightness oscillations during thermonuclear X-ray bursts were discovered with the Rossi X-ray Timing Explorer (RXTE) in early 1996. Spectral and timing evidence strongly supports the conclusion that these oscillations are caused by rotational modulation of the burst emission and that they reveal the spin frequency of neutron stars in low mass X-ray binaries, a long sought goal of X-ray astronomy. Studies carried out over the past year have led to the discovery of burst oscillations in four new sources, bringing to ten the number with confirmed burst oscillations. I review the status of our knowledge of these oscillations and indicate how they can be used to probe the physics of neutron stars. For a few burst oscillation sources it has been proposed that the strongest and most ubiquitous frequency is actually the first overtone of the spin frequency and hence that two nearly antipodal hot spots are present on the neutron star. This inference has important implications for both the physics of thermonuclear burning as well as the mass - radius relation for neutron stars, so its confirmation is crucial. I discuss recent attempts to confirm this hypothesis for 4U 1636-53, the source for which a signal at the putative fundamental (290 Hz) has been claimed.

  13. X-ray lithography using holographic images

    DOE Patents [OSTI]

    Howells, M.S.; Jacobsen, C.

    1997-03-18

    Methods for forming X-ray images having 0.25 {micro}m minimum line widths on X-ray sensitive material are presented. A holographic image of a desired circuit pattern is projected onto a wafer or other image-receiving substrate to allow recording of the desired image in photoresist material. In one embodiment, the method uses on-axis transmission and provides a high flux X-ray source having modest monochromaticity and coherence requirements. A layer of light-sensitive photoresist material on a wafer with a selected surface is provided to receive the image(s). The hologram has variable optical thickness and variable associated optical phase angle and amplitude attenuation for transmission of the X-rays. A second embodiment uses off-axis holography. The wafer receives the holographic image by grazing incidence reflection from a hologram printed on a flat metal or other highly reflecting surface or substrate. In this second embodiment, an X-ray beam with a high degree of monochromaticity and spatial coherence is required. 15 figs.

  14. In Operando X-ray Diffraction and Transmission X-ray Microscopy of Lithium Sulfur Batteries

    E-Print Network [OSTI]

    Cui, Yi

    In Operando X-ray Diffraction and Transmission X-ray Microscopy of Lithium Sulfur Batteries Johanna Information ABSTRACT: Rechargeable lithium-sulfur (Li-S) batteries hold great potential for high not well understood. In this Article, these changes in Li-S batteries are studied in operando by X

  15. X-Ray Data from the X-Ray Data Booklet Online

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Thompson, Albert C.; Attwood, David T.; Gullikson, Eric M.; Howells, Malcolm R.; Kortright, Jeffrey B.; Robinson, Arthur L.; Underwood, James H.; Kim, Kwang-Je; Kirz, Janos; Lindau, Ingolf; Pianetta, Piero; Winick, Herman; Williams, Gwyn P.; Scofield, James H.

    The original X-Ray Data Booklet, published in 1985, became a classic reference source. The online version has been significantly revised and updated to reflect today's science. Hundreds of pages of authoritative data provide the x-ray properties of elements, information on synchrotron radiation, scattering processes, optics and detectors, and other related calculations, formulas, and data tables.

  16. X-ray Clusters at High Redshift

    E-Print Network [OSTI]

    I. M. Gioia

    1997-11-30

    As the largest gravitationally bound structures known, clusters provide clear constraints on the formation of structure and on the composition of the universe. Despite their extreme importance for cosmology the number of clusters at high redshift (z > 0.75) is rather small. There are only a few X-ray emitting examples reported and a handful of optically-selected ones. These clusters can provide stringent constrains on theories of large scale structure formation, if they are massive enough. I will review the status of these distant X-ray selected clusters. These objects are of special importance because their X-ray emission implies that they are massive, comparable to low redshift examples, and their existence is problematic for some theories of structure formation.

  17. Radiobiological studies using gamma and x rays.

    SciTech Connect (OSTI)

    Potter, Charles Augustus; Longley, Susan W.; Scott, Bobby R. [Lovelace Respiratory Research Institute, Albuquerque, NM; Lin, Yong [Lovelace Respiratory Research Institute, Albuquerque, NM; Wilder, Julie [Lovelace Respiratory Research Institute, Albuquerque, NM; Hutt, Julie A. [Lovelace Respiratory Research Institute, Albuquerque, NM; Padilla, Mabel T. [Lovelace Respiratory Research Institute, Albuquerque, NM; Gott, Katherine M. [Lovelace Respiratory Research Institute, Albuquerque, NM

    2013-02-01

    There are approximately 500 self-shielded research irradiators used in various facilities throughout the U.S. These facilities use radioactive sources containing either 137Cs or 60Co for a variety of biological investigations. A report from the National Academy of Sciences[1] described the issues with security of particular radiation sources and the desire for their replacement. The participants in this effort prepared two peer-reviewed publications to document the results of radiobiological studies performed using photons from 320-kV x rays and 137Cs on cell cultures and mice. The effectiveness of X rays was shown to vary with cell type.

  18. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformationJesse Bergkamp GraduateResidentialLensless Imaging of WholeX-Ray Imaging inX-Ray

  19. Catalog of supersoft X-ray sources

    E-Print Network [OSTI]

    J. Greiner

    2000-05-11

    This catalog comprises an up-to-date (December 1999) list of luminous (>10^36 erg/s), binary supersoft X-ray sources. This electronic version (including the accompannying Web-pages) supersedes the printed version of Greiner (1996).

  20. Multiple wavelength X-ray monochromators

    DOE Patents [OSTI]

    Steinmeyer, P.A.

    1992-11-17

    An improved apparatus and method is provided for separating input x-ray radiation containing first and second x-ray wavelengths into spatially separate first and second output radiation which contain the first and second x-ray wavelengths, respectively. The apparatus includes a crystalline diffractor which includes a first set of parallel crystal planes, where each of the planes is spaced a predetermined first distance from one another. The crystalline diffractor also includes a second set of parallel crystal planes inclined at an angle with respect to the first set of crystal planes where each of the planes of the second set of parallel crystal planes is spaced a predetermined second distance from one another. In one embodiment, the crystalline diffractor is comprised of a single crystal. In a second embodiment, the crystalline diffractor is comprised of a stack of two crystals. In a third embodiment, the crystalline diffractor includes a single crystal that is bent for focusing the separate first and second output x-ray radiation wavelengths into separate focal points. 3 figs.

  1. Multiple wavelength X-ray monochromators

    DOE Patents [OSTI]

    Steinmeyer, Peter A. (Arvada, CO)

    1992-11-17

    An improved apparatus and method is provided for separating input x-ray radiation containing first and second x-ray wavelengths into spatially separate first and second output radiation which contain the first and second x-ray wavelengths, respectively. The apparatus includes a crystalline diffractor which includes a first set of parallel crystal planes, where each of the planes is spaced a predetermined first distance from one another. The crystalline diffractor also includes a second set of parallel crystal planes inclined at an angle with respect to the first set of crystal planes where each of the planes of the second set of parallel crystal planes is spaced a predetermined second distance from one another. In one embodiment, the crystalline diffractor is comprised of a single crystal. In a second embodiment, the crystalline diffractor is comprised of a stack of two crystals. In a third embodiment, the crystalline diffractor includes a single crystal that is bent for focussing the separate first and second output x-ray radiation wavelengths into separate focal points.

  2. SLAC All Access: X-ray Microscope

    ScienceCinema (OSTI)

    Nelson, Johanna; Liu, Yijin

    2014-06-13

    SLAC physicists Johanna Nelson and Yijin Liu give a brief overview of the X-ray microscope at the Stanford Synchrotron Radiation Lightsource (SSRL) that is helping improve rechargeable-battery technology by letting researchers peek into the inner workings of batteries as they operate.

  3. Rise Time Measurement for Ultrafast X-Ray Pulses

    DOE Patents [OSTI]

    Celliers, Peter M.; Weber, Franz A.; Moon, Stephen J.

    2005-04-05

    A pump-probe scheme measures the rise time of ultrafast x-ray pulses. Conventional high speed x-ray diagnostics (x-ray streak cameras, PIN diodes, diamond PCD devices) do not provide sufficient time resolution to resolve rise times of x-ray pulses on the order of 50 fs or less as they are being produced by modern fast x-ray sources. Here, we are describing a pump-probe technique that can be employed to measure events where detector resolution is insufficient to resolve the event. The scheme utilizes a diamond plate as an x-ray transducer and a p-polarized probe beam.

  4. X-ray imaging crystal spectrometer for extended X-ray sources

    DOE Patents [OSTI]

    Bitter, Manfred L. (Princeton, NJ); Fraenkel, Ben (Jerusalem, IL); Gorman, James L. (Bordentown, NJ); Hill, Kenneth W. (Lawrenceville, NJ); Roquemore, A. Lane (Cranbury, NJ); Stodiek, Wolfgang (Princeton, NJ); von Goeler, Schweickhard E. (Princeton, NJ)

    2001-01-01

    Spherically or toroidally curved, double focusing crystals are used in a spectrometer for X-ray diagnostics of an extended X-ray source such as a hot plasma produced in a tokomak fusion experiment to provide spatially and temporally resolved data on plasma parameters using the imaging properties for Bragg angles near 45. For a Bragg angle of 45.degree., the spherical crystal focuses a bundle of near parallel X-rays (the cross section of which is determined by the cross section of the crystal) from the plasma to a point on a detector, with parallel rays inclined to the main plain of diffraction focused to different points on the detector. Thus, it is possible to radially image the plasma X-ray emission in different wavelengths simultaneously with a single crystal.

  5. Evaluating the variability of ceramics with x-ray fluorescence

    SciTech Connect (OSTI)

    Crown, P.L.; Schwalbe, L.A.; London, J.R.

    1984-01-01

    Our assessment of prehistoric trade in ceramics depends on our ability to identify and distinguish different sources of manufacture. For the American Southwest, archaeologists have proposed various models of ceramic manufacture and exchange. Until recently, conflicting hypotheses were tested mainly on the basis of petrographic analysis of nonplastic tempering materials. We have extended these analyses to include x-ray fluorescence (XRF). XRF provides a fast and inexpensive means of analyzing large numbers of samples. Since 1982, approximately 500 prehistoric sherds and 40 prepared clay and mineral samples have been examined with XRF. Multivariate statistical techniques have been applied to help identify groupings of samples with possible archaeological significance.

  6. Development of a Novel Tunable X-Ray Source for the RPI-LINAC

    SciTech Connect (OSTI)

    Y. Danon; R.C. Block

    2004-11-30

    This document summarizes the results of a three year effort to develop a parametric x-ray (PXR) source. The emphasis of this research was to demonstrate production of high yield monoenergetic x-rays. Production of PXR is accomplished by placing a crystal in a relativistic electron beam. The process was first demonstrated in 1985 in Russia. Numerous papers were written about the characteristics of PXR from both experimental and theoretical perspectives. The advantage of PXR over other monoenergetic x-ray sources is that it is produced at large angle relative to the electron beam and at high intensity. None of the previous work described in the literature capitalized on this effect to study what is required in order to generate an effective monoenergetic x-ray source that can be used for practical applications. The work summarized here describes the process done in order to optimize the PXR production process by selecting an appropriate crystal and the optimal conditions. The research focused on production of 18 keV x-rays which are suitable for mammography however the results are not limited to this application or energy range. We are the first group to demonstrate x-ray imaging using PXR. Such sources can improve current medical imaging modalities. More research is required in order to design a prototype of a compact source.

  7. X-Ray Diffraction Microscopy of Magnetic Structures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    X-Ray Diffraction Microscopy of Magnetic Structures Print science brief icon Scientists working at ALS Beamline 12.0.2.2 have demonstrated a new x-ray technique for producing...

  8. ALS X-Rays Shine a New Light on Catalysis

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    times science has used high-brilliance x-rays to look so closely at these reactions. Lead author Dr. David Mueller at the ALS using x-rays to characterize working fuel cells....

  9. Using Light to Control How X Rays Interact with Matter

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Using Light to Control How X Rays Interact with Matter Using Light to Control How X Rays Interact with Matter Print Wednesday, 27 January 2010 00:00 Schemes that use one light...

  10. A World's Top-10 X-ray Crystal Structure

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    A World's Top-10 X-ray Crystal Structure October 7, 2014 Bookmark and Share Philip Coppens An x-ray crystal structure solved by Philip Coppens has been chosen as one of the world's...

  11. Dawn of x-ray nonlinear optics | Stanford Synchrotron Radiation...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Dawn of x-ray nonlinear optics Wednesday, July 8, 2015 - 3:00pm SLAC, Redtail Hawk Conference Room 108A Speaker: David Reis, PULSE Program Description X-ray free electron lasers...

  12. Staff Research Physicist (X-Ray Spectroscopy) | Princeton Plasma...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    position to work on X-ray spectroscopy, atomic physics, X-ray instrumentation, and high energy density physics. Near-term research goals include participating in the design,...

  13. X-ray mammography with synchrotron radiation

    SciTech Connect (OSTI)

    Burattini, E. (CNR and INFN-Laboratori Nazionali di Frascati, Frascati, Rome (Italy)); Gambaccini, M.; Marziani, M.; Rimondi, O. (Dipartimento di Fisica dell'Universita and Sezione INFN di Ferrara, Ferrara (Italy)); Indovina, P.L. (Dipartimento di Scienze Fisiche dell'Universita and Sezione INFN di Napoli, Naples (Italy)); Pocek, M.; Simonetti, G. (Istituto di Radiologia, Ospedale Sant'Eugenio, Universita di Tor Vergata, Rome (Italy)); Benassi, M.; Tirelli, C. (Istituto Nazionale del Cancro, Regina Elena, Rome (Italy)); Passariello, R. (Cattedra di Radiologia, Universita dell'Aquila, L'Aquila (Italy))

    1992-01-01

    For the first time in the literature, radiographs of breast phantoms were obtained using several monochromatic synchrotron radiation x-ray beams of selected energy in the range from 14 to 26 keV. In addition, after optimization of the photon energy as a function of the phantom thickness, several mammographs were obtained on surgically removed human breast specimens containing cancer nodules. Comparison between radiographs using a conventional x-ray unit and those obtained of the same specimens utilizing synchrotron monochromatic beams clearly shows that higher contrast and better resolution can be achieved with synchrotron radiation. These results demonstrate the possibility of obtaining radiographs of excised human breast tissue containing a greater amount of radiological information using synchrotron radiation.

  14. X-ray radiography for container inspection

    DOE Patents [OSTI]

    Katz, Jonathan I. (Clayton, MO); Morris, Christopher L. (Los Alamos, NM)

    2011-06-07

    Arrangements of X-ray inspection systems are described for inspecting high-z materials in voluminous objects such as containers. Inspection methods may involve generating a radiographic image based on detected attenuation corresponding to a pulsed beams of radiation transmitted through a voluminous object. The pulsed beams of radiation are generated by a high-energy source and transmitted substantially downward along an incident angle, of approximately 1.degree. to 30.degree., to a vertical axis extending through the voluminous object. The generated radiographic image may be analyzed to detect on localized high attenuation representative of high-z materials and to discriminate high-z materials from lower and intermediate-z materials on the basis of the high density and greater attenuation of high-z material for higher energy (3-10 MeV) X-rays, and the compact nature of threatening masses of fissionable materials.

  15. X-rays from Supernova Remnants

    E-Print Network [OSTI]

    B. Aschenbach

    2002-08-28

    A summary of X-ray observations of supernova remnants is presented including the explosion fragment A of the Vela SNR, Tycho, N132D, RX J0852-4622, the Crab Nebula and the 'bulls eye', and SN 1987A, high-lighting the progress made with Chandra and XMM-Newton and touching upon the questions which arise from these observations and which might inspire future research.

  16. The X-ray Telescope of CAST

    E-Print Network [OSTI]

    M. Kuster; H. Bräuninger; S. Cébrian; M. Davenport; C. Elefteriadis; J. Englhauser; H. Fischer; J. Franz; P. Friedrich; R. Hartmann; F. H. Heinsius; D. H. H. Hoffmann; G. Hoffmeister; J. N. Joux; D. Kang; K. Königsmann; R. Kotthaus; T. Papaevangelou; C. Lasseur; A. Lippitsch; G. Lutz; J. Morales; A. Rodríguez; L. Strüder; J. Vogel; K. Zioutas

    2007-05-10

    The Cern Axion Solar Telescope (CAST) is in operation and taking data since 2003. The main objective of the CAST experiment is to search for a hypothetical pseudoscalar boson, the axion, which might be produced in the core of the sun. The basic physics process CAST is based on is the time inverted Primakoff effect, by which an axion can be converted into a detectable photon in an external electromagnetic field. The resulting X-ray photons are expected to be thermally distributed between 1 and 7 keV. The most sensitive detector system of CAST is a pn-CCD detector combined with a Wolter I type X-ray mirror system. With the X-ray telescope of CAST a background reduction of more than 2 orders off magnitude is achieved, such that for the first time the axion photon coupling constant g_agg can be probed beyond the best astrophysical constraints g_agg < 1 x 10^-10 GeV^-1.

  17. Portable Parallel Beam X-Ray Diffraction System | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    than 50 pounds, and uses about 50 watts of power. The X-Beam uses polycapillary x-ray optics to collect x-rays over a large solid angle from a low-power x-ray source and to form...

  18. Small Angle X-ray Scattering (SAXS) Laboratory Learning Experiences

    E-Print Network [OSTI]

    Meagher, Mary

    .A. & Svergun D.I. (1987). Structure Analysis by Small-Angle X-Ray and Neutron Scattering. NY: Plenum PressSmall Angle X-ray Scattering (SAXS) Laboratory Learning Experiences o - Use of small angle X-ray scattering instrumentation o - Programs that you will use SAXS (BRUKER AXS) PRIMUS (Konarev, Volkov, Koch

  19. Femtosecond laser-electron x-ray source

    DOE Patents [OSTI]

    Hartemann, Frederic V.; Baldis, Hector A.; Barty, Chris P.; Gibson, David J.; Rupp, Bernhard

    2004-04-20

    A femtosecond laser-electron X-ray source. A high-brightness relativistic electron injector produces an electron beam pulse train. A system accelerates the electron beam pulse train. The femtosecond laser-electron X-ray source includes a high intra-cavity power, mode-locked laser and an x-ray optics system.

  20. Monitoring x-ray beam damage on lipid films by an integrated Brewster angle microscope/x-ray diffractometer

    E-Print Network [OSTI]

    Lee, Ka Yee C.

    Polyunsaturated lipids with conjugated tails are easily dam- aged by x-ray irradiation in the presence of oxygen samples and thin films has been detected since the beginning of x-ray studies. Dam- age to lipid samples

  1. X-Ray Interactions with Matter from the Center for X-Ray Optics (CXRO)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Henke, B. L.; Gullikson, E. M.; Davis, J. C.

    The primary interactions of low-energy x-rays within condensed matter, viz. photoabsorption and coherent scattering, are described for photon energies outside the absorption threshold regions by using atomic scattering factors. The atomic scattering factors may be accurately determined from the atomic photoabsorption cross sections using modified Kramers-Kronig dispersion relations. From a synthesis of the currently available experimental data and recent theoretical calculations for photoabsorption, the angle-independent, forward-scattering components of the atomic scattering factors have been thus semiempirically determined and tabulated here for 92 elements and for the region 50-30,000 eV. Atomic scattering factors for all angles of coherent scattering and at the higher photon energies are obtained from these tabulated forward-scattering values by adding a simple angle-dependent form-factor correction. The incoherent scattering contributions that become significant for the light elements at the higher photon energies are similarly determined. The basic x-ray interaction relations that are used in applied x-ray physics are presented here in terms of the atomic scattering factors. The bulk optical constants are also related to the atomic scattering factors. These atomic and optical relations are applied to the detailed calculation of the reflectivity characteristics of a series of practical x-ray mirror, multilayer, and crystal monochromators. Comparisons of the results of this semiempirical,"atom-like", description of x-ray interactions for the low-energy region with those of experiment and ab initio theory are presented.

  2. Experimental investigation of beam heating in a soft X-ray scanning transmission X-ray microscope

    E-Print Network [OSTI]

    Hitchcock, Adam P.

    Experimental investigation of beam heating in a soft X-ray scanning transmission X-ray microscope and an accuracy of Æ1 C has been fabricated for scanning transmission X-ray microscopes (STXM). Here we describe at temperatures near their respective melting points as a means of checking for possible sample heating caused

  3. Apparatus for monitoring X-ray beam alignment

    DOE Patents [OSTI]

    Steinmeyer, P.A.

    1991-10-08

    A self-contained, hand-held apparatus is provided for monitoring alignment of an X-ray beam in an instrument employing an X-ray source. The apparatus includes a transducer assembly containing a photoresistor for providing a range of electrical signals responsive to a range of X-ray beam intensities from the X-ray beam being aligned. A circuit, powered by a 7.5 VDC power supply and containing an audio frequency pulse generator whose frequency varies with the resistance of the photoresistor, is provided for generating a range of audible sounds. A portion of the audible range corresponds to low X-ray beam intensity. Another portion of the audible range corresponds to high X-ray beam intensity. The transducer assembly may include an a photoresistor, a thin layer of X-ray fluorescent material, and a filter layer transparent to X-rays but opaque to visible light. X-rays from the beam undergoing alignment penetrate the filter layer and excite the layer of fluorescent material. The light emitted from the fluorescent material alters the resistance of the photoresistor which is in the electrical circuit including the audio pulse generator and a speaker. In employing the apparatus, the X-ray beam is aligned to a complete alignment by adjusting the X-ray beam to produce an audible sound of the maximum frequency. 2 figures.

  4. HgMn Stars as apparent X-ray emitters

    E-Print Network [OSTI]

    Hubrig, S; Mathys, G

    1998-01-01

    In the ROSAT all-sky survey 11 HgMn stars were detected as soft X-ray emitters (Berghoefer, Schmitt & Cassinelli 1996). Prior to ROSAT, X-ray observations with the Einstein Observatory had suggested that stars in the spectral range B5-A7 are devoid of X-ray emission. Since there is no X-ray emitting mechanism available for these stars (also not for HgMn stars), the usual argument in the case of an X-ray detected star of this spectral type is the existence of an unseen low-mass companion which is responsible for the X-ray emission. The purpose of the present work is to use all available data for our sample of X-ray detected HgMn stars and conclude on the nature of possible companions.

  5. X-Ray Imaging Crystal Spectrometer for Extended X-Ray Sources

    SciTech Connect (OSTI)

    Bitter, Manfred L.; Fraekel, Benjamin; Gorman, James L.; Hill, Kenneth W.; Roquemore, Lane A.; Stodiek, Wolfgang; Goeler, Schweickhard von

    1999-05-01

    Spherically or toroidally curved, double focusing crystals are used in a spectrometer for X-ray diagnostics of an extended X-ray source such as a hot plasma produced in a tokamak fusion experiment to provide spatially and temporally resolved data on plasma parameters such as ion temperature, toroidal and poloidal rotation, electron temperature, impurity ion charge-state distributions, and impurity transport. The imaging properties of these spherically or toroidally curved crystals provide both spectrally and spatially resolved X-ray data from the plasma using only one small spherically or toroidally curved crystal, thus eliminating the requirement for a large array of crystal spectrometers and the need to cross-calibrate the various crystals.

  6. X-ray emission properties of galaxies in Abell 3128

    E-Print Network [OSTI]

    Russell J. Smith

    2003-07-15

    We use archival Chandra X-ray Observatory data to investigate X-ray emission from early-type galaxies in the rich z=0.06 cluster Abell 3128. By combining the X-ray count-rates from an input list of optically-selected galaxies, we obtain a statistical detection of X-ray flux, unbiased by X-ray selection limits. Using 87 galaxies with reliable Chandra data, X-ray emission is detected for galaxies down to M_B ~ -19.0, with only an upper limit determined for galaxies at M_B ~ -18.3. The ratio of X-ray to optical luminosities is consistent with recent determinations of the low-mass X-ray binary content of nearby elliptical galaxies. Taken individually, in contrast, we detect significant (3sigma) flux for only six galaxies. Of these, one is a foreground galaxy, while two are optically-faint galaxies with X-ray hardness ratios characteristic of active galactic nuclei. The remaining three detected galaxies are amongst the optically-brightest cluster members, and have softer X-ray spectra. Their X-ray flux is higher than that expected from X-ray binaries, by a factor 2-10; the excess suggests these galaxies have retained their hot gaseous haloes. The source with the highest L_X / L_B ratio is of unusual optical morphology with prominent sharp-edged shells. Notwithstanding these few exceptions, the cluster population overall exhibits X-ray properties consistent with their emission being dominated by X-ray binaries. We conclude that in rich cluster environments, interaction with the ambient intra-cluster medium acts to strip most galaxies of their hot halo gas.

  7. Autism Genetic Testing: Psychological Factors Associated with the Test Decisions Among Parents of Children with Autism Spectrum Disorders (ASDs) in Taiwan 

    E-Print Network [OSTI]

    Xu, Lei

    2014-07-09

    Autism spectrum disorders (ASDs) are a group of highly inheritable disorders. Genetic testing for ASD is anticipated to be offered in Taiwan in the near future. Therefore, it is critical to explore the psychological factors regarding the test...

  8. Metrology for the advancement of x-ray optics at the ALS

    E-Print Network [OSTI]

    Goldberg, Kenneth

    2014-01-01

    S. Yuan et al. , X-ray Optics and Instrumentation 2010,in X-ray and Neutron Optics, Springer, Berlin S. G. AlcockX-ray beam metrology and X-ray optic alignment by Hartmann

  9. SMB, Small Angle X-Ray Scattering

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust, High-Throughput Analysis of Protein1-0845*RV 14800Small Angle X-Ray Scattering Home »

  10. SMB, X-ray Absorption Spectroscopy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust, High-Throughput Analysis of Protein1-0845*RV 14800Small Angle X-Ray Scattering Home

  11. SMB, X-ray Emission Spectroscopy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust, High-Throughput Analysis of Protein1-0845*RV 14800Small Angle X-Ray Scattering

  12. SMB, X-ray Fluorescence Imaging

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust, High-Throughput Analysis of Protein1-0845*RV 14800Small Angle X-Ray

  13. X-Ray Microscopy | Argonne National Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWindX-Ray ImagingIn the

  14. X-ray Microscopy and Imaging: FAQs

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWindX-Ray

  15. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformationJesse Bergkamp GraduateResidentialLensless Imaging of WholeX-Ray Imaging in

  16. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformationJesse Bergkamp GraduateResidentialLensless Imaging of WholeX-Ray Imaging

  17. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would likeUniverseIMPACTThousand CubicResourcelogo and-E C H N I CLensless X-Ray Imaging in

  18. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would likeUniverseIMPACTThousand CubicResourcelogo and-E C H N I CLensless X-Ray Imaging

  19. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would likeUniverseIMPACTThousand CubicResourcelogo and-E C H N I CLensless X-Ray ImagingLensless

  20. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would likeUniverseIMPACTThousand CubicResourcelogo and-E C H N I CLensless X-Ray

  1. A laboratory-based hard x-ray monochromator for high-resolution x-ray emission spectroscopy and x-ray absorption near edge structure measurements

    SciTech Connect (OSTI)

    Seidler, G. T. Mortensen, D. R.; Remesnik, A. J.; Pacold, J. I.; Ball, N. A.; Barry, N.; Styczinski, M.; Hoidn, O. R.

    2014-11-15

    We report the development of a laboratory-based Rowland-circle monochromator that incorporates a low power x-ray (bremsstrahlung) tube source, a spherically bent crystal analyzer, and an energy-resolving solid-state detector. This relatively inexpensive, introductory level instrument achieves 1-eV energy resolution for photon energies of ?5 keV to ?10 keV while also demonstrating a net efficiency previously seen only in laboratory monochromators having much coarser energy resolution. Despite the use of only a compact, air-cooled 10 W x-ray tube, we find count rates for nonresonant x-ray emission spectroscopy comparable to those achieved at monochromatized spectroscopy beamlines at synchrotron light sources. For x-ray absorption near edge structure, the monochromatized flux is small (due to the use of a low-powered x-ray generator) but still useful for routine transmission-mode studies of concentrated samples. These results indicate that upgrading to a standard commercial high-power line-focused x-ray tube or rotating anode x-ray generator would result in monochromatized fluxes of order 10{sup 6}–10{sup 7} photons/s with no loss in energy resolution. This work establishes core technical capabilities for a rejuvenation of laboratory-based hard x-ray spectroscopies that could have special relevance for contemporary research on catalytic or electrical energy storage systems using transition-metal, lanthanide, or noble-metal active species.

  2. X-ray Luminosity Functions of Young Stars in Taurus-Auriga-Perseus

    E-Print Network [OSTI]

    B. Stelzer

    2000-11-23

    X-ray luminosity functions (XLF) are frequently used to assess the properties of the X-ray emission from a given sample of stars, and particularly important for a comparison of different groups of stars. I present the results from a detailed analysis of the XLF of pre-main sequence T Tauri Stars in Taurus-Auriga and young main-sequence objects (represented by the Pleiades and Hyades cluster). The study is based on the ROSAT public archive. Various possible biases related to the sample selection are described, and their influence on the luminosity distributions is discussed.

  3. Soft x-ray reduction camera for submicron lithography

    DOE Patents [OSTI]

    Hawryluk, Andrew M. (2708 Rembrandt Pl., Modesto, CA 95356); Seppala, Lynn G. (7911 Mines Rd., Livermore, CA 94550)

    1991-01-01

    Soft x-ray projection lithography can be performed using x-ray optical components and spherical imaging lenses (mirrors), which form an x-ray reduction camera. The x-ray reduction is capable of projecting a 5x demagnified image of a mask onto a resist coated wafer using 4.5 nm radiation. The diffraction limited resolution of this design is about 135 nm with a depth of field of about 2.8 microns and a field of view of 0.2 cm.sup.2. X-ray reflecting masks (patterned x-ray multilayer mirrors) which are fabricated on thick substrates and can be made relatively distortion free are used, with a laser produced plasma for the source. Higher resolution and/or larger areas are possible by varying the optic figures of the components and source characteristics.

  4. Fabrication process for a gradient index x-ray lens

    DOE Patents [OSTI]

    Bionta, Richard M. (Livermore, CA); Makowiecki, Daniel M. (Livermore, CA); Skulina, Kenneth M. (Livermore, CA)

    1995-01-01

    A process for fabricating high efficiency x-ray lenses that operate in the 0.5-4.0 keV region suitable for use in biological imaging, surface science, and x-ray lithography of integrated circuits. The gradient index x-ray optics fabrication process broadly involves co-sputtering multi-layers of film on a wire, followed by slicing and mounting on block, and then ion beam thinning to a thickness determined by periodic testing for efficiency. The process enables the fabrication of transmissive gradient index x-ray optics for the 0.5-4.0 keV energy range. This process allows the fabrication of optical elements for the next generation of imaging and x-ray lithography instruments m the soft x-ray region.

  5. Fabrication process for a gradient index x-ray lens

    DOE Patents [OSTI]

    Bionta, R.M.; Makowiecki, D.M.; Skulina, K.M.

    1995-01-17

    A process is disclosed for fabricating high efficiency x-ray lenses that operate in the 0.5-4.0 keV region suitable for use in biological imaging, surface science, and x-ray lithography of integrated circuits. The gradient index x-ray optics fabrication process broadly involves co-sputtering multi-layers of film on a wire, followed by slicing and mounting on block, and then ion beam thinning to a thickness determined by periodic testing for efficiency. The process enables the fabrication of transmissive gradient index x-ray optics for the 0.5-4.0 keV energy range. This process allows the fabrication of optical elements for the next generation of imaging and x-ray lithography instruments in the soft x-ray region. 13 figures.

  6. Density gradient free electron collisionally excited x-ray laser

    DOE Patents [OSTI]

    Campbell, E.M.; Rosen, M.D.

    1984-11-29

    An operational x-ray laser is provided that amplifies 3p-3s transition x-ray radiation along an approximately linear path. The x-ray laser is driven by a high power optical laser. The driving line focused optical laser beam illuminates a free-standing thin foil that may be associated with a substrate for improved structural integrity. This illumination produces a generally cylindrically shaped plasma having an essentially uniform electron density and temperature, that exists over a long period of time, and provides the x-ray laser gain medium. The x-ray laser may be driven by more than one optical laser beam. The x-ray laser has been successfully demonstrated to function in a series of experimental tests.

  7. Density gradient free electron collisionally excited X-ray laser

    DOE Patents [OSTI]

    Campbell, Edward M. (Pleasanton, CA); Rosen, Mordecai D. (Berkeley, CA)

    1989-01-01

    An operational X-ray laser (30) is provided that amplifies 3p-3s transition X-ray radiation along an approximately linear path. The X-ray laser (30) is driven by a high power optical laser. The driving line focused optical laser beam (32) illuminates a free-standing thin foil (34) that may be associated with a substrate (36) for improved structural integrity. This illumination produces a generally cylindrically shaped plasma having an essentially uniform electron density and temperature, that exists over a long period of time, and provides the X-ray laser gain medium. The X-ray laser (30) may be driven by more than one optical laser beam (32, 44). The X-ray laser (30) has been successfully demonstrated to function in a series of experimental tests.

  8. ISOCAM Photometry of Narrow-Line X-ray Galaxies

    E-Print Network [OSTI]

    J. D. Law-Green; A. Zezas; M. J. Ward; C. Boisson

    1998-12-23

    Mid-infrared photometry of the hosts of Narrow-Line X-ray Galaxies at 6 microns and 12 microns has been attempted with ISOCAM. No conclusive detections have been made. This implies that these are quiescent objects with little or no active star-formation. Neither X-ray binaries nor starburst-driven superwinds are consistent explanations for the X-ray emission in these objects. We conclude that these NLXGs are predominantly AGN-powered.

  9. X-ray transmission movies of spontaneous dynamic events

    SciTech Connect (OSTI)

    Smilowitz, L.; Henson, B. F.; Holmes, M.; Novak, A.; Oschwald, D.; Dolgonos, P.; Qualls, B.

    2014-11-15

    We describe a new x-ray radiographic imaging system which allows for continuous x-ray transmission imaging of spontaneous dynamic events. We demonstrate this method on thermal explosions in three plastic bonded formulations of the energetic material octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine. We describe the x-ray imaging system and triggering developed to enable the continuous imaging of a thermal explosion.

  10. X-ray interferometry with spherically bent crystals (abstract)

    SciTech Connect (OSTI)

    Koch, Jeffrey A.

    2001-01-01

    Recent progress in manufacturing high-quality spherically bent crystals allows highly monochromatic x-ray beams to be produced, and allows efficient x-ray imaging with {mu}m-scale resolution. This article explores some of the constraints for x-ray interferometry utilizing spherically bent crystals and laser-produced plasma sources, and discusses several shearing interferometer concepts that might be experimentally investigated.

  11. Legacy of the X-Ray Laser Program

    SciTech Connect (OSTI)

    Nilsen, J.

    1993-08-06

    The X-Ray Laser Program has evolved from a design effort focusing on developing a Strategic Defense Initiative weapon that protects against Soviet ICBMs to a scientific project that is producing new technologies for industrial and medical research. While the great technical successes and failures of the X-ray laser itself cannot be discussed, this article presents the many significant achievements made as part of the X-ray laser effort that are now being used for other applications at LLNL.

  12. Ultra-short wavelength x-ray system

    DOE Patents [OSTI]

    Umstadter, Donald (Ann Arbor, MI); He, Fei (Ann Arbor, MI); Lau, Yue-Ying (Potomac, MD)

    2008-01-22

    A method and apparatus to generate a beam of coherent light including x-rays or XUV by colliding a high-intensity laser pulse with an electron beam that is accelerated by a synchronized laser pulse. Applications include x-ray and EUV lithography, protein structural analysis, plasma diagnostics, x-ray diffraction, crack analysis, non-destructive testing, surface science and ultrafast science.

  13. X-ray micromodulated luminescence tomography in dual-cone ...

    E-Print Network [OSTI]

    2014-07-01

    Jul 16, 2014 ... source, a polycapillary lens, and an electron multiplying charge coupled device ... sources generate x-rays by accelerating electrons into high-z.

  14. X-Ray Characterization of Diesel Sprays | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Sprays X-Ray Characterization of Diesel Sprays 2005 Diesel Engine Emissions Reduction (DEER) Conference Presentations and Posters 2005deerpowell.pdf More Documents & Publications...

  15. Probing Spatial, Electronic Structures with X-ray Scattering...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Probing Spatial, Electronic Structures with X-ray Scattering, Spectroscopic Techniques Wednesday, September 5, 2012 - 10:45am SLAC, Bldg. 137, Room 226 Gang Chen Seminar:...

  16. X-Ray Diffraction Microscopy of Magnetic Structures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    x-ray diffraction to measure the electron density of complicated molecules. The formula used to make these calculations contains terms that relate to the electron spin of...

  17. In situ X-ray Characterization of Energy Storage Materials |...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Scholar, SSRL MSD Hard X-ray Department A key factor in the global move towards clean, renewable energy is the electrification of the automobile. Current battery technology...

  18. Dissociation of strong acid revisited: X-ray photoelectron spectroscop...

    Office of Scientific and Technical Information (OSTI)

    X-ray photoelectron spectroscopy and molecular dynamics simulations of HNO3 in water Citation Details In-Document Search Title: Dissociation of strong acid revisited:...

  19. Simulating Wavefront Correction via Deformable Mirrors at X-Ray...

    Office of Scientific and Technical Information (OSTI)

    Resource Type: Conference Resource Relation: Conference: Presented at: X-ray Adaptive Optics, San Diego, CA, United States, Aug 14 - Aug 14, 2012 Research Org: Lawrence Livermore...

  20. Resonant Soft X-Ray Scattering - Combining Structural with Spectroscop...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    spectroscopy has become an important tool in understanding the electronic structure of materials. Resonant absorption edges in the soft x-ray regime are especially interesting...

  1. A Record Run for the APS X-ray Source

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    signals that comprise radiation interlock systems protecting personnel and equipment; * Beam diagnostics controlling multiple x-ray beams simultaneously while utilizing more than...

  2. Insight into obscure transition uncovered by X-rays | Argonne...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of X-ray techniques. This transition has ramifications for material design for electronics and sensors. The transition between being electrically conductive (metallic) at...

  3. Advances in X-Ray Diagnostics of Diesel Fuel Sprays

    Broader source: Energy.gov [DOE]

    Recent advances in high-speed X-ray imaging has shown several distinct behaviors of commercial fuel injectors that cannot be seen with more conventional techniques.

  4. X-ray image reconstruction from a diffraction pattern alone

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Marchesini, Stefano

    X-ray diffraction pattern of a sample of 50 nm colloidal gold particles, recorded at a wavelength of 2.1 nm.

  5. ALS X-Rays Shine a New Light on Catalysis

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    were able to directly observe redox processes in thin-film iron and cobalt perovskite oxide electrocatalysts using surface-sensitive, x-ray absorption spectroscopy while...

  6. Electronic structure of titania aerogels: Soft x-ray absorption...

    Office of Scientific and Technical Information (OSTI)

    Journal Article: Electronic structure of titania aerogels: Soft x-ray absorption study Citation Details In-Document Search Title: Electronic structure of titania aerogels: Soft...

  7. X-ray compass for determining device orientation

    DOE Patents [OSTI]

    Da Silva, L.B.; Matthews, D.L.; Fitch, J.P.; Everett, M.J.; Colston, B.W.; Stone, G.F.

    1999-06-15

    An apparatus and method for determining the orientation of a device with respect to an x-ray source are disclosed. In one embodiment, the present invention is coupled to a medical device in order to determine the rotational orientation of the medical device with respect to the x-ray source. In such an embodiment, the present invention is comprised of a scintillator portion which is adapted to emit photons upon the absorption of x-rays emitted from the x-ray source. An x-ray blocking portion is coupled to the scintillator portion. The x-ray blocking portion is disposed so as to vary the quantity of x-rays which penetrate the scintillator portion based upon the particular rotational orientation of the medical device with respect to the x-ray source. A photon transport mechanism is also coupled to the scintillator portion. The photon transport mechanism is adapted to pass the photons emitted from the scintillator portion to an electronics portion. By analyzing the quantity of the photons, the electronics portion determines the rotational orientation of the medical device with respect to the x-ray source. 25 figs.

  8. X-ray Emission from Isolated Be Stars

    E-Print Network [OSTI]

    David H. Cohen

    2000-08-22

    I discuss the X-ray observations of Be stars, and how their properties compare to non-emission B stars. I focus on several specific stars that show high flux levels and variability but also report on several interesting survey results. The Be X-ray properties are discussed in the context of wind-shock X-ray emission from normal OB stars as well as in the context of general mechanisms that have been proposed to explain the Be phenomenon. Finally, I conclude with a discussion of the spectral diagnostics that will be available from the new generation of X-ray telescopes.

  9. X-ray compass for determining device orientation

    DOE Patents [OSTI]

    Da Silva, Luiz B. (Danville, CA); Matthews, Dennis L. (Moss Beach, CA); Fitch, Joseph P. (Livermore, CA); Everett, Matthew J. (Pleasanton, CA); Colston, Billy W. (Livermore, CA); Stone, Gary F. (Livermore, CA)

    1999-01-01

    An apparatus and method for determining the orientation of a device with respect to an x-ray source. In one embodiment, the present invention is coupled to a medical device in order to determine the rotational orientation of the medical device with respect to the x-ray source. In such an embodiment, the present invention is comprised of a scintillator portion which is adapted to emit photons upon the absorption of x-rays emitted from the x-ray source. An x-ray blocking portion is coupled to the scintillator portion. The x-ray blocking portion is disposed so as to vary the quantity of x-rays which penetrate the scintillator portion based upon the particular rotational orientation of the medical device with respect to the x-ray source. A photon transport mechanism is also coupled to the scintillator portion. The photon transport mechanism is adapted to pass the photons emitted from the scintillator portion to an electronics portion. By analyzing the quantity of the photons, the electronics portion determines the rotational orientation of the medical device with respect to the x-ray source.

  10. Characterization of spatially resolved high resolution x-ray...

    Office of Scientific and Technical Information (OSTI)

    Characterization of spatially resolved high resolution x-ray spectrometers for high energy density physics and light source experiments Citation Details In-Document Search Title:...

  11. X-ray microscopy at CNM | Argonne National Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWindX-RayX-Ray ScienceX-RayX-ray

  12. Neutron and X-ray Scattering Techniques have proved so successful in condensed matter studies that a wide variety of sample environments have been developed in consquence. Many

    E-Print Network [OSTI]

    Boyer, Edmond

    Foreword Neutron and X-ray Scattering Techniques have proved so successful in condensed matter whose function is to develop and optimise the techniques appropriate to neutron scattering. Since other neutron and X-ray research centres have similar technical support groups, it was felt timely to unité

  13. Constraints on jet X-ray emission in low/hard state X-ray binaries

    E-Print Network [OSTI]

    Thomas J. Maccarone

    2005-03-31

    We show that the combination of the similarities between the X-ray properties of low luminosity accreting black holes and accreting neutron stars, combined with the differences in their radio properties argues that the X-rays from these systems are unlikely to be formed in the relativistic jets. Specifically, the spectra of extreme island state neutron stars and low/hard state black holes are known to be indistinguishable, while the power spectra from these systems are known to show only minor differences beyond what would be expected from scaling the characteristic variability frequencies by the mass of the compact object. The spectral and temporal similarities thus imply a common emission mechanism that has only minor deviations from having all key parameters scaling linearly with the mass of the compact object, while we show that this is inconsistent with the observations that the radio powers of neutron stars are typically about 30 times lower than those of black holes at the same X-ray luminosity. We also show that an abrupt luminosity change would be expected when a system makes a spectral state transition from a radiatively inefficient jet dominated accretion flow to a thin disk dominated flow, but that such a change is not seen.

  14. Femtosecond x-ray absorption spectroscopy with hard x-ray free electron laser

    SciTech Connect (OSTI)

    Katayama, Tetsuo; Togashi, Tadashi; Tono, Kensuke; Kameshima, Takashi; Inubushi, Yuichi; Sato, Takahiro; Hatsui, Takaki; Yabashi, Makina; Obara, Yuki; Misawa, Kazuhiko; Bhattacharya, Atanu; Kurahashi, Naoya; Ogi, Yoshihiro; Suzuki, Toshinori; Molecular Reaction Dynamics Research Team, RIKEN Center for Advanced Photonics, 2-1 Hirosawa, Wako 351-0198

    2013-09-23

    We have developed a method of dispersive x-ray absorption spectroscopy with a hard x-ray free electron laser (XFEL), generated by a self-amplified spontaneous emission (SASE) mechanism. A transmission grating was utilized for splitting SASE-XFEL light, which has a relatively large bandwidth (?E/E ? 5 × 10{sup ?3}), into several branches. Two primary split beams were introduced into a dispersive spectrometer for measuring signal and reference spectra simultaneously. After normalization, we obtained a Zn K-edge absorption spectrum with a photon-energy range of 210 eV, which is in excellent agreement with that measured by a conventional wavelength-scanning method. From the analysis of the difference spectra, the noise ratio was evaluated to be ?3 × 10{sup ?3}, which is sufficiently small to trace minute changes in transient spectra induced by an ultrafast optical laser. This scheme enables us to perform single-shot, high-accuracy x-ray absorption spectroscopy with femtosecond time resolution.

  15. X-rays from magnetically channeled winds of OB stars

    E-Print Network [OSTI]

    David H. Cohen

    2008-01-30

    OB stars with strong radiation-driven stellar winds and large-scale magnetic fields generate strong and hard X-ray emission via the Magnetically Channeled Wind Shock (MCWS) mechanism. In this brief paper, I describe four separate X-ray diagnostics of the MCWS mechanism in OB stars, with applications to the prototype young O star, theta-1 Ori C.

  16. Electromagnetic Application: X-RAY Alawi H. Ba-Surrah

    E-Print Network [OSTI]

    Masoudi, Husain M.

    , Pulyui published high-quality x-ray images in journals in Paris and London. · Nikola Tesla In April 1887, Nikola Tesla began to investigate X-rays using high voltages and tubes of his own design, as well. The principle behind Tesla's device is called the Bremsstrahlung process, in which a high-energy secondary X

  17. HIGH-RESOLUTION X-RAY SPECTROSCOPY OF CRUCIS: A

    E-Print Network [OSTI]

    Cohen, David

    a corona; clear presence of UV driven wind at moderate temperatures; lack of wind X-ray absorption edges the years, consen- sus has thus instead favored an Intrinsic Wind Shock (IWS) model, in which the X-ray emission comes from shocks distributed throughout the wind, most likely arising from the strong, intrinsic

  18. X-rays from Hot Stars: Stellar Astronomy Research with

    E-Print Network [OSTI]

    Cohen, David

    emission lines Hot stars*: massive outflows ("stellar winds") ­ are the x-rays associated with these winds can actually take an image of its "wind nebula" ­ in all other cases, we infer the presence of a wind a model for fitting the detailed shapes of x-ray emission line profiles from hot star winds The very hot

  19. National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    15th National School on Neutron and X-ray Scattering August 10 - 24, 2013 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major Ridge National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang

  20. Thirteenth National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    Thirteenth National School on Neutron and X-ray Scattering June 11 ­ June 25, 2011 at Argonne of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang, Suzanne

  1. Sixteenth National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    Pennycook, Steve

    Sixteenth National School on Neutron and X-ray Scattering June 14-28, 2014 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major's Neutron Scattering Science Division. Scientific Directors: Suzanne G.E. te Velthuis, Esen Ercan Alp

  2. Neutron and X-ray Scattering Study of Magnetic Manganites

    E-Print Network [OSTI]

    Boothroyd, Andrew

    Neutron and X-ray Scattering Study of Magnetic Manganites Graeme Eoin Johnstone A Thesis submitted are performed using a variety of neutron scattering and x-ray scattering techniques. The electronic ground for analysing the results of the polarised neutron scattering experiment. There are a large number of people who

  3. National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    Pennycook, Steve

    National School on Neutron and X-ray Scattering May 30 ­ June 13, 2009 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang, Suzanne

  4. Fourteenth National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    Pennycook, Steve

    Fourteenth National School on Neutron and X-ray Scattering August 12 - 25, 2012 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major Ridge National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang

  5. Twelfth National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    Pennycook, Steve

    Twelfth National School on Neutron and X-ray Scattering June 12 ­ June 26, 2010 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang, Suzanne

  6. Tenth National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    Pennycook, Steve

    Tenth National School on Neutron and X-ray Scattering September 24 - October 11, 2008 at Argonne of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang, Suzanne

  7. Millisecond oscillations during thermonuclear X-ray bursts

    E-Print Network [OSTI]

    Muno, Michael Patrick, 1975-

    2002-01-01

    I analyze 68 oscillation trains detected in a search of 159 thermonuclear bursts from eight neutron star X-ray binaries observed with the Rossi X-ray Timing Explorer. I use all data that were public as of September 2001. ...

  8. Microwave and hard X-ray imaging observations of

    E-Print Network [OSTI]

    White, Stephen

    Microwave and hard X-ray imaging observations of energetic electrons in solar flares: event of 2003 to nonthermal energies are seen via microwave and hard X-ray emission from the solar corona. Imaging sophisticated and fully dedicated solar radio telescope operating at microwave frequencies (17 & 34 GHz) capable

  9. Formation, disruption and energy output of Population III X-ray binaries

    E-Print Network [OSTI]

    Ryu, Taeho; Perna, Rosalba

    2015-01-01

    The first astrophysical objects shaped the cosmic environment by reionizing and heating the intergalactic medium (IGM). In particular, X-rays are very efficient at heating the IGM before it became completely ionized, an effect that can be measured through the 21 cm line of neutral hydrogen. High-mass X-ray binaries (HMXBs), known to be prolific X-ray sources in star-forming galaxies at lower redshifts, are prime candidates for driving the thermal evolution of the IGM at redshifts $z > 20$. Despite their importance, the formation efficiency of HMXBs from the first stellar populations is not well understood---as such, their collective X-ray emission and the subsequent imprint on the 21 cm signature are usually evaluated using free parameters. Using $N$-body simulations, we estimate the rate of HMXB formation via mutual gravitational interactions of nascent, small groups of the first stars (Pop III stars). We run two sets of calculations: one in which stars form in small groups of five in nearly Keplerian initia...

  10. Broadband high resolution X-ray spectral analyzer

    DOE Patents [OSTI]

    Silver, E.H.; Legros, M.; Madden, N.W.; Goulding, F.; Landis, D.

    1998-07-07

    A broad bandwidth high resolution X-ray fluorescence spectrometer has a performance that is superior in many ways to those currently available. It consists of an array of 4 large area microcalorimeters with 95% quantum efficiency at 6 keV and it produces X-ray spectra between 0.2 keV and 7 keV with an energy resolution of 7 to 10 eV. The resolution is obtained at input count rates per array element of 10 to 50 Hz in real-time, with analog pulse processing and thermal pile-up rejection. This performance cannot be matched by currently available X-ray spectrometers. The detectors are incorporated into a compact and portable cryogenic refrigerator system that is ready for use in many analytical spectroscopy applications as a tool for X-ray microanalysis or in research applications such as laboratory and astrophysical X-ray and particle spectroscopy. 6 figs.

  11. ZAP! The X-Ray Laser is Born

    SciTech Connect (OSTI)

    Ratner, Daniel

    2009-11-17

    SLAC has converted its giant particle accelerator into the world's first X-ray laser. By a billion fold the world's brightest X-ray source, the laser packs a trillion photons into pulses as short as a millionth of a billionth of a second. The ultra-bright, ultra-short X-ray pulses will drive a wide range of new experiments, as scientists strip electrons from atoms, photograph single molecules and make movies of chemical reactions. How has SLAC accomplished such feats of X-ray wizardry? Attend this public lecture to learn about the basics of an X-ray laser, the technologies at SLAC that make it possible, and the exciting new experiments now underway.

  12. ON THE DISCREPANCY BETWEEN THEORETICAL AND X-RAY CONCENTRATION-MASS RELATIONS FOR GALAXY CLUSTERS

    SciTech Connect (OSTI)

    Rasia, E. [Department of Physics, University of Michigan, 450 Church Street, Ann Arbor, MI 48109 (United States); Borgani, S. [Dipartimento di Fisica dell' Università di Trieste, Sezione di Astronomia, via Tiepolo 11, I-34131 Trieste (Italy); Ettori, S.; Meneghetti, M. [INAF, Osservatorio Astronomico di Bologna, via Ranzani 1, I-40127, Bologna (Italy); Mazzotta, P. [Dipartimento di Fisica, Università di Roma Tor Vergata, via della Ricerca Scientifica, I-00133, Roma (Italy)

    2013-10-10

    In the past 15 years, the concentration-mass relation has been investigated diffusely in theoretical studies. On the other hand, only recently has this relation been derived from X-ray observations. When that happened, the results caused a certain level of concern: the X-ray normalizations and slopes were found significantly dissimilar from those predicted by theory. We analyzed 52 galaxy clusters and groups, simulated with different descriptions of the physical processes that affect the baryonic component, with the purpose of determining whether these discrepancies are real or induced by biases in the computation of the concentration parameter or in the determination of the selection function of the cluster sample for which the analysis is carried out. In particular, we investigate how the simulated concentration-mass relation depends (1) on the radial range used to derive the concentration; (2) on the presence of baryons in the simulations, and on the effect of star formation and feedback from supernovae and active galactic nuclei (AGNs). Finally, we evaluate (3) how the results differ when adopting an X-ray approach for the analysis and (4) how the selection function based on X-ray luminosity can impact the results. All effects studied go in the direction of alleviating the discrepancy between observations and simulations, although with different significance: while the choice of the radial range to fit the profiles and the inclusion of the baryonic component play only a minor role, the X-ray approach to reconstruct the mass profiles and the selection of the cluster sample have a strong impact on the resulting concentration-mass relation. Extending the fit to the most central regions or reducing the fitting radius from the virial boundary to the typical X-ray external radius causes an increase of the normalization in radiative simulations by 5%-10%. In the second case, we measure a slope that is up to twice steeper than that derived by using the typical theoretical radial range. Radiative simulations including only supernova feedback produce 30% higher concentrations than the dark matter case. Such a difference is largely reduced when including the effect of AGN feedback. The concentration-mass relation derived from the X-ray synthetic catalog is significantly steeper due to the combination of several different effects, such as environment, dynamical state and dynamical history of the clusters, bias in mass and temperature measurements, and their dependence on the radius and on the mass of the system. Finally, selecting clusters according to their X-ray luminosity produces a net increase in both normalization and slope of the relation, since at fixed mass, the most luminous clusters are also the most concentrated.

  13. Bent Crystal X-Ray Mirrors for Time-Resolved Experiments with Femtosecond Laser-Produced X-ray Pulses

    E-Print Network [OSTI]

    von der Linde, D.

    Bent Crystal X-Ray Mirrors for Time-Resolved Experiments with Femtosecond Laser-Produced X@iep.physik.uni-essen.de Abstract. In the last few years, bent crystal X-ray mirrors have played an important role in time, for example, with the help of toroidally bent crystals which allow a monochromatic point-to-point imaging

  14. X-RAY EMISSION FROM PLANETS AND COMETS: RELATIONSHIP WITH SOLAR X-RAYS AND SOLAR WIND

    E-Print Network [OSTI]

    Bergen, Universitetet i

    X-RAY EMISSION FROM PLANETS AND COMETS: RELATIONSHIP WITH SOLAR X-RAYS AND SOLAR WIND ANIL BHARDWAJ extraterrestrische Physik, Garching, Germany 6 Applied Physics Laboratory, John Hopkins University, Laurel, MD 20723 planets Jupiter and Saturn in the energy range of 0.2-2 keV. These flares are found to occur in tandem

  15. Millimeter, Microwave, Hard X--ray and Soft X--ray Observations of Energetic Electron Populations in Solar Flares

    E-Print Network [OSTI]

    White, Stephen

    Millimeter, Microwave, Hard X--ray and Soft X--ray Observations of Energetic Electron Populations in Solar Flares M. R. Kundu 1 , S. M. White 1 , N. Gopalswamy 1 and J. Lim 1,2 1 Dept. of Astronomy, Univ. of Maryland, College Park MD 20742 2 Solar Astronomy 264--33, Caltech, Pasadena CA 91125 Submitted

  16. Deep x-ray lithography for micromechanics

    SciTech Connect (OSTI)

    Christenson, T.R. [Sandia National Labs., Albuquerque, NM (United States); Guckel, H. [Wisconsin Univ., Madison, WI (United States). Dept. of Electrical and Computer Engineering

    1995-08-01

    Extensions of the German LIGA process have brought about fabrication capability suitable for cost effective production of precision engineered components. The process attributes allow fabrication of mechanical components which are not capable of being made via conventional subtractive machining methods. Two process improvements have been responsible for this extended capability which involve the areas of thick photoresist application and planarization via precision lapping. Application of low-stress x-ray photoresist has been achieved using room temperature solvent bonding of a preformed photoresist sheet. Precision diamond lapping and polishing has provided a flexible process for the planarization of a wide variety of electroplated metals in the presence of photoresist. Exposure results from the 2.5 GeV National Synchrotron Light Source storage ring at Brookhaven National Laboratory have shown that structural heights of several millimeter and above are possible. The process capabilities are also well suited for microactuator fabrication. Linear and rotational magnetic microactuators have been constructed which use coil winding technology with LIGA fabricated coil forms. Actuator output forces of 1 milliNewton have been obtained with power dissipation on the order of milliWatts. A rotational microdynamometer system which is capable of measuring torque-speed data is also discussed.

  17. X-ray spectral states of microquasars

    E-Print Network [OSTI]

    Julien Malzac; Renaud Belmont

    2008-10-25

    We discuss the origin of the dramatically different X-ray spectral shapes observed in the Low Hard State (LHS: dominated by thermal comptonisation) and the High Soft State (HSS: dominated by the accretion disc thermal emission and non-thermal comptonisation in the corona). We present numerical simulations using a new code accounting for the so-called synchrotron boiler effect. These numerical simulations when compared to the data allow us to constrain the magnetic field and temperature of the hot protons in the corona. For the hard state of Cygnus X-1 we find a magnetic field below equipartition with radiation, suggesting that the corona is not powered through magnetic field dissipation (as assumed in most accretion disc corona models). On the other hand, our results also point toward proton temperatures that are substantially lower than typical temperatures of the ADAF models. Finally, we show that in both spectral states Comptonising plasma could be powered essentially through power-law acceleration of non-thermal electrons, which are then partly thermalised by the synchrotron and Coulomb boiler. This suggests that, contrary to current beliefs, the corona of the HSS and that of the LHS could be of very similar nature. The differences between the LHS and HSS coronal spectra would then be predominantly caused by the strong disc soft cooling emission which is present in the HSS and absent in the LHS.

  18. Whirlpool: ENERGY STAR Referral (ASD2524VE)

    Broader source: Energy.gov [DOE]

    DOE referred the matter of Whirlpool's Amana-brand dishwasher model ASD2524VE to the EPA for appropriate action after DOE testing showed that the model does not meet the ENERGY STAR specification.

  19. Complete multiwavelength evolution of galactic black hole transients during outburst decay. II. Compact jets and X-ray variability properties

    SciTech Connect (OSTI)

    Dinçer, T.; Kalemci, E.; Tomsick, J. A.; Buxton, M. M.; Bailyn, C. D.

    2014-11-01

    We investigated the relation between compact jet emission and X-ray variability properties of all black hole transients with multiwavelength coverage during their outburst decays. We studied the evolution of all power spectral components (including low-frequency quasi-periodic oscillations; QPOs), and related this evolution to changes in jet properties tracked by radio and infrared observations. We grouped sources according to their tracks in the radio/X-ray luminosity relation and show that the standards show stronger broadband X-ray variability than outliers at a given X-ray luminosity when the compact jet turns on. This trend is consistent with the internal shock model and can be important for the understanding of the presence of tracks in the radio/X-ray luminosity relation. We also observed that the total and the QPO rms amplitudes increase together during the earlier part of the outburst decay, but after the compact jet turns, either the QPO disappears or its rms amplitude decreases significantly while the total rms amplitudes remain high. We discuss these results with a scenario including a variable corona and a non-variable disk with a mechanism for the QPO separate from the mechanism that creates broad components. Finally, we evaluated the timing predictions of the magnetically dominated accretion flow model that can explain the presence of tracks in the radio/X-ray luminosity relation.

  20. NEW X-RAY DETECTIONS OF WNL STARS

    SciTech Connect (OSTI)

    Skinner, Stephen L.; Zhekov, Svetozar A.; Guedel, Manuel; Schmutz, Werner; Sokal, Kimberly R.

    2012-05-15

    Previous studies have demonstrated that putatively single nitrogen-type Wolf-Rayet stars (WN stars) without known companions are X-ray sources. However, almost all WN star X-ray detections so far have been of earlier WN2-WN6 spectral subtypes. Later WN7-WN9 subtypes (also known as WNL stars) have proved more difficult to detect, an important exception being WR 79a (WN9ha). We present here new X-ray detections of the WNL stars WR 16 (WN8h) and WR 78 (WN7h). These new results, when combined with previous detections, demonstrate that X-ray emission is present in WN stars across the full range of spectral types, including later WNL stars. The two WN8 stars observed to date (WR 16 and WR 40) show unusually low X-ray luminosities (L{sub x} ) compared to other WN stars, and it is noteworthy that they also have the lowest terminal wind speeds (v{sub {infinity}}). Existing X-ray detections of about a dozen WN stars reveal a trend of increasing L{sub x} with wind luminosity L{sub wind} = (1/2)M-dot v{sup 2}{sub {infinity}}, suggesting that wind kinetic energy may play a key role in establishing X-ray luminosity levels in WN stars.

  1. NSLS-II X-Ray Diagnostics Development

    SciTech Connect (OSTI)

    ILINSKI, P.

    2011-03-28

    NSLS-II x-ray diagnostics will provide continuous online data of electron beam dimensions, which will be used to derive electron beam emittance and energy spread. It will also provide information of electron beam tilt for coupling evaluation. X-ray diagnostics will be based on imaging of bending magnet and three-pole wiggler synchrotron radiation sources. Diagnostics from three-pole wiggler source will be used to derive particles energy spread. Beta and dispersion functions will have to be evaluated for emittance and particles energy spread calculations. Due to small vertical source sizes imaging need to be performed in x-ray energy range. X-ray optics with high numerical aperture, such as compound refractive lens, will be used to achieve required spatial resolution. Optical setups with different magnifications in horizontal and vertical directions fill be employed to deal with large aspect ratio of the source. X-ray diagnostics setup will include x-ray imaging optics, monochromatization, x-ray imaging and recording components.

  2. Soft-x-ray spectroscopy study of nanoscale materials

    SciTech Connect (OSTI)

    Guo, J.-H.

    2005-07-30

    The ability to control the particle size and morphology of nanoparticles is of crucial importance nowadays both from a fundamental and industrial point of view considering the tremendous amount of high-tech applications. Controlling the crystallographic structure and the arrangement of atoms along the surface of nanostructured material will determine most of its physical properties. In general, electronic structure ultimately determines the properties of matter. Soft X-ray spectroscopy has some basic features that are important to consider. X-ray is originating from an electronic transition between a localized core state and a valence state. As a core state is involved, elemental selectivity is obtained because the core levels of different elements are well separated in energy, meaning that the involvement of the inner level makes this probe localized to one specific atomic site around which the electronic structure is reflected as a partial density-of-states contribution. The participation of valence electrons gives the method chemical state sensitivity and further, the dipole nature of the transitions gives particular symmetry information. The new generation synchrotron radiation sources producing intensive tunable monochromatized soft X-ray beams have opened up new possibilities for soft X-ray spectroscopy. The introduction of selectively excited soft X-ray emission has opened a new field of study by disclosing many new possibilities of soft X-ray resonant inelastic scattering. In this paper, some recent findings regarding soft X-ray absorption and emission studies of various nanostructured systems are presented.

  3. EXIST: A High Sensitivity Hard X-ray Imaging Sky Survey Mission for ISS

    E-Print Network [OSTI]

    J. Grindlay; L. Bildsten; D. Chakrabarty; M. Elvis; A. Fabian; F. Fiore; N. Gehrels; C. Hailey; F. Harrison; D. Hartmann; T. Prince; B. Ramsey; R. Rothschild; G. Skinner; S. Woosley

    1999-12-18

    A deep all-sky imaging hard x-ray survey and wide-field monitor is needed to extend soft (ROSAT) and medium (ABRIXAS2) x-ray surveys into the 10-100 keV band (and beyond) at comparable sensitivity (~0.05 mCrab). This would enable discovery and study of >3000 obscured AGN, which probably dominate the hard x-ray background; detailed study of spectra and variability of accreting black holes and a census of BHs in the Galaxy; Gamma-ray bursts and associated massive star formation (PopIII) at very high redshift and Soft Gamma-ray Repeaters throughout the Local Group; and a full galactic survey for obscured supernova remnants. The Energetic X-ray Imaging Survey Telescope (EXIST) is a proposed array of 8 x 1m^2 coded aperture telescopes fixed on the International Space Station (ISS) with 160deg x 40deg field of view which images the full sky each 90 min orbit. EXIST has been included in the most recent NASA Strategic Plan as a candidate mission for the next decade. An overview of the science goals and mission concept is presented.

  4. Apparatus for generating x-ray holograms

    DOE Patents [OSTI]

    Rhodes, C.K.; Boyer, K.; Solem, J.C.; Haddad, W.S.

    1990-09-11

    Apparatus for x-ray microholography of living biological materials. A Fourier transform holographic configuration is described as being most suitable for the 3-dimensional recording of the physical characteristics of biological specimens. The use of a spherical scatterer as a reference and a charge-coupled device two-dimensional detector array placed in the forward direction relative to the incident x-radiation for viewing electromagnetic radiation simultaneously scattered from both the specimen and the reference scatterer permits the ready reconstruction of the details of the specimen from the fringe pattern detected by the charge-coupled device. For example, by using a nickel reference scatter at 4.5 nm, sufficient reference illumination is provided over a wide enough angle to allow similar resolution in both transverse and longitudinal directions. Both laser and synchrotron radiation sources are feasible for generating microholographs. Operation in the water window (2.4 to 4.5 nm) should provide maximum contrast for features of the specimen and spatial resolution on the order of the wavelength of x-radiation should be possible in all three dimensions, which is sufficient for the visualization of many biological features. It is anticipated that the present apparatus will find utility in other areas as well where microscopic physical details of a specimen are important. A computational procedure which enables the holographic data collected by the detector to be used to correct for misalignments introduced by inexact knowledge of the relative positions of the spherical reference scatterer and the sample under investigation has been developed. If the correction is performed prior to reconstruction, full compensation can be achieved and a faithfully reconstructed image produced. 7 figs.

  5. Apparatus for generating x-ray holograms

    DOE Patents [OSTI]

    Rhodes, Charles K. (Chicago, IL); Boyer, Keith (Los Alamos, NM); Solem, Johndale C. (Los Alamos, NM); Haddad, Waleed S. (Chicago, IL)

    1990-01-01

    Apparatus for x-ray microholography of living biological materials. A Fourier transform holographic configuration is described as being most suitable for the 3-dimensional recording of the physical characteristics of biological specimens. The use of a spherical scatterer as a reference and a charge-coupled device two-dimensional detector array placed in the forward direction relative to the incident x-radiation for viewing electromagnetic radiation simultaneously scattered from both the specimen and the reference scatterer permits the ready reconstruction of the details of the specimen from the fringe pattern detected by the charge-coupled device. For example, by using a nickel reference scatter at 4.5 nm, sufficient reference illumination is provided over a wide enough angle to allow similar resolution in both transverse and longitudinal directions. Both laser and synchrotron radiation sources are feasible for generating microholographs. Operation in the water window (2.4 to 4.5 nm) should provide maximum contrast for features of the specimen and spatial resolution on the order of the wavelength of x-radiation should be possible in all three dimensions, which is sufficient for the visualization of many biological features. It is anticipated that the present apparatus will find utility in other areas as well where microscopic physical details of a specimen are important. A computational procedure which enables the holographic data collected by the detector to be used to correct for misalignments introduced by inexact knowledge of the relative positions of the spherical reference scatterer and the sample under investigation has been developed. If the correction is performed prior to reconstruction, full compensation can be achieved and a faithfully reconstructed image produced.

  6. Resonant x-ray magnetic scattering in holmium

    SciTech Connect (OSTI)

    Gibbs, D.

    1991-01-01

    We review the results of resonant x-ray magnetic scattering experiments on the rare earth metal holmium. When the incident incident x-ray energy is tuned near the L{sub III} absorption edge, large resonant enhancements of the magnetic scattering and resonant integer harmonics are observed. These results are analyzed within the theory of x-ray resonance exchange scattering assuming electric dipole (2p {yields} 5d) and quadrupole (2p {yields} 4f) transitions among atomic orbitals. 30 refs., 5 figs.

  7. Characterization of X-ray generator beam profiles.

    SciTech Connect (OSTI)

    Mitchell, Dean J; Harding, Lee T.; Thoreson, Gregory G.; Theisen, Lisa Anne; Parmeter, John Ethan; Thompson, Kyle Richard

    2013-07-01

    T to compute the radiography properties of various materials, the flux profiles of X-ray sources must be characterized. This report describes the characterization of X-ray beam profiles from a Kimtron industrial 450 kVp radiography system with a Comet MXC-45 HP/11 bipolar oil-cooled X-ray tube. The empirical method described here uses a detector response function to derive photon flux profiles based on data collected with a small cadmium telluride detector. The flux profiles are then reduced to a simple parametric form that enables computation of beam profiles for arbitrary accelerator energies.

  8. X-ray backscatter imaging of nuclear materials

    DOE Patents [OSTI]

    Chapman, Jeffrey Allen; Gunning, John E; Hollenbach, Daniel F; Ott, Larry J; Shedlock, Daniel

    2014-09-30

    The energy of an X-ray beam and critical depth are selected to detect structural discontinuities in a material having an atomic number Z of 57 or greater. The critical depth is selected by adjusting the geometry of a collimator that blocks backscattered radiation so that backscattered X-ray originating from a depth less than the critical depth is not detected. Structures of Lanthanides and Actinides, including nuclear fuel rod materials, can be inspected for structural discontinuities such as gaps, cracks, and chipping employing the backscattered X-ray.

  9. Optical and X-ray Variability of Blazars

    E-Print Network [OSTI]

    Gupta, A C

    2015-01-01

    Here we report our recent results of variability studies in optical and X-ray bands of three blazars namely 3C 273, PKS 2155 - 304 and BL Lacertae with XMM-Newton. We found large amplitude optical to X-rays variability in 3C 273, and PKS 2155 - 304 on year time scale. In 3C 273, we noticed that synchrotron cooling and particle acceleration are at work at different epoch of observations. In PKS 2155 - 304, spectral energy distribution from optical to X-ray is fitted with LPPL (log parabolic + power law) model. In BL Lacertae, optical flux and degree of polarization were anti-correlated.

  10. Spatiotemporal focusing dynamics in plasmas at X-ray wavelength

    SciTech Connect (OSTI)

    Sharma, A., E-mail: a-physics2001@yahoo.com; Tibai, Z. [Institute of Physics, University of Pecs, Pecs–7624 (Hungary)] [Institute of Physics, University of Pecs, Pecs–7624 (Hungary); Hebling, J. [Institute of Physics, University of Pecs, Pecs–7624 (Hungary) [Institute of Physics, University of Pecs, Pecs–7624 (Hungary); Szentagothai Research Centre, University of Pecs, Pecs-7624 (Hungary); Mishra, S. K. [Institute for Plasma Research, Gandhinagar (India)] [Institute for Plasma Research, Gandhinagar (India)

    2014-03-15

    Using a finite curvature beam, we investigate here the spatiotemporal focusing dynamics of a laser pulse in plasmas at X-ray wavelength. We trace the dependence of curvature parameter on the focusing of laser pulse and recognize that the self-focusing in plasma is more intense for the X-ray laser pulse with curved wavefront than with flat wavefront. The simulation results demonstrate that spatiotemporal focusing dynamics in plasmas can be controlled with the appropriate choice of beam-plasma parameters to explore the high intensity effects in X-ray regime.

  11. X-ray afterglows from gamma-ray bursts

    E-Print Network [OSTI]

    M. Tavani

    1997-03-24

    We consider possible interpretations of the recently detected X- ray afterglow from the gamma-ray burst source GRB 970228. Cosmological and Galactic models of gamma-ray bursts predict different flux and spectral evolution of X-ray afterglows. We show that models based on adiabatic expansion of relativistic forward shocks require very efficient particle energization or post-burst re-acceleration during the expansion. Cooling neutron star models predict a very distinctive spectral and flux evolution that can be tested in current X-ray data.

  12. Laser-Produced Coherent X-Ray Sources

    SciTech Connect (OSTI)

    Donald Umstadter

    2007-01-31

    We study the generation of x-rays from the interaction of relativistic electrons with ultra-intense laser pulse either directly or via laser generated ion channels. The laser pulse acts as the accelerator and wiggler leading to an all-optical synchrotron-like x-ray source. The mm sized accelerator and micron-sized wiggler leads to a compact source of high brightness, ultrafast x-rays with applications in relativistic nonlinear optics, ultrafast chemistry, biology, inner-shell electronic processes and phase transitions.

  13. X-Ray Diffraction Microscopy of Magnetic Structures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWind Power >X-RayX-RayX-Ray

  14. Radiation exposure in X-ray-based imaging techniques used in osteoporosis

    E-Print Network [OSTI]

    Damilakis, John; Adams, Judith E.; Guglielmi, Giuseppe; Link, Thomas M.

    2010-01-01

    and nonradiologists in dual-energy X-ray absorptiometrymorphometry studies using dual-energy X-ray absorptiometry.dose measurements in dual energy X-ray absorptiometry (DXA).

  15. X-ray optics metrology limited by random noise, instrumental drifts, and systematic errors

    E-Print Network [OSTI]

    Yashchuk, Valeriy V.

    2010-01-01

    X-ray optics metrology limited by random noise, instrumentalUSA Center for X-ray Optics, Lawrence Berkeley Nationaland reflecting x-ray optics suitable for micro- and nano-

  16. Beyond 3-D X-ray Imaging: Methodology Development and Applications...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to the availability of the new generation of X-ray sources and the advanced X-ray optics. The advanced X-ray Optics along with novel methodology has made it possible to...

  17. Automated suppression of errors in LTP-II slope measurements with x-ray optics

    E-Print Network [OSTI]

    Ali, Zulfiqar

    2011-01-01

    slope measurements with x-ray optics Zulfiqar Ali, Curtis L.with state-of-the-art x-ray optics. Significant suppressionscanning, metrology of x-ray optics, deflectometry Abstract

  18. Synchrotron X-ray Scattering Studies of Rapidly Evolving Nanoscale Interfacial Systems /

    E-Print Network [OSTI]

    Dai, Yeling

    2013-01-01

    Stanley. X-ray and neutron scattering from rough surfaces.Stanley. X-ray and neutron scattering from rough surfaces.grazing incidence x-ray and neutron scattering from ordered

  19. Analysis of Order Formation in Block Copolymer Thin Films Using Resonant Soft X-Ray Scattering

    E-Print Network [OSTI]

    Virgili, Justin M.; Tao, Yuefei; Kortright, Jeffrey B.; Balsara, Nitash P.; Segalman, Rachel A.

    2006-01-01

    Methods of X-Ray and Neutron Scattering in Polymer Science.µ t for X-ray and neutron scattering experiments is unity;18 In classical scattering of light, X-rays or neutrons the

  20. X-ray scattering studies of structure and dynamics of surfaces and interfaces of polymeric liquids

    E-Print Network [OSTI]

    Jiang, Zhang

    2007-01-01

    Evanescent X-ray and Neutron Scattering. Springer-Verlag,Methods of X-ray and neutron scattering in polymer science.Stanley. X-ray and neutron scattering from rough surfaces.

  1. Imaging nanoscale magnetic structures with polarized soft x-ray photons

    E-Print Network [OSTI]

    Fischer, P.

    2010-01-01

    with polarized soft X-ray photons Peter Fischer and Mi -polarized soft X-ray photons which provide a strong X-rayhigh intense soft X-ray photon pulses hold the promise of

  2. A New Scheme for Stigmatic X-ray Imaging with Large Magnification...

    Office of Scientific and Technical Information (OSTI)

    F; Beiersdorfer, P; Wang, E; Sanchez del Rio, M; Caughey, T A 70 PLASMA PHYSICS AND FUSION TECHNOLOGY X-ray Imaging X-ray Imaging This paper describes a new x-ray scheme for...

  3. Achieving hard X-ray nanofocusing using a wedged multilayer Laue...

    Office of Scientific and Technical Information (OSTI)

    anticipate that continuous development on wedged MLLs will advance x-ray nanofocusing optics to new frontiers and enrich capabilities and opportunities for hard X-ray microscopy....

  4. Phase Tomography Using X-ray Talbot Interferometer

    SciTech Connect (OSTI)

    Momose, A.; Yashiro, W.; Moritake, M. [Graduate School of Frontier Sciences, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan); Takeda, Y. [Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573 (Japan); Uesugi, K.; Suzuki, Y. [SPring-8/JASRI, 1-1-1 Kouto, Mikazuki, Hyogo 679-5198 (Japan); Hattori, T. [Laboratory of Advanced Science and Technology for Industry, University of Hyogo, 3-1-2 Kouto, Kamigori, Hyogo 678-1205 (Japan)

    2007-01-19

    A biological tomography result obtained with an X-ray Talbot interferometer is reported. An X-ray Talbot interferometer was constructed using an amplitude grating fabricated by X-ray lithography at the LIGA beamline of NewSUBARU and gold electroplating. The pitch and pattern thickness of the grating were 8 {mu}m and 30 {mu}m, respectively. The effective area was 20 x 20 mm2, which was entirely illuminated with a wide beam available at the medium-length beamline 20B2 of SPring-8, allowing the acquisition of a three-dimensional tomogram of almost the whole body of a fish. The resulting image obtained with 17.7 keV X-rays revealed organs with bones in the same view.

  5. Performance enhancement approaches for a dual energy x-ray

    E-Print Network [OSTI]

    Fu, Kenneth

    2010-01-01

    Evans, J.P.O. , “Stereoscopic dual energy imaging for targetCrawford, C.R. , “Dual Energy Volumetric X-ray Tomographicimages in 4–10 MeV Dual- energy customs system for material

  6. X-ray emission from the terrestrial magnetosheath

    E-Print Network [OSTI]

    Robertson, Ina Picket; Cravens, Thomas Edward

    2003-04-29

    [1] X-rays are generated throughout the terrestrial magnetosheath as a consequence of charge transfer collisions between heavy solar wind ions and geocoronal neutrals. The solar wind ions resulting from these collisions are left in highly excited...

  7. Active pixel sensors for X-ray astronomy

    E-Print Network [OSTI]

    Cohen, Matthew (Matthew L.)

    2005-01-01

    An active pixel sensor array, APS-1, has been fabricated for the purpose of scientific x-ray detection. This thesis presents the results of testing the device. Alternate design architectures are explored. Recommendations ...

  8. Accreting X-ray millisecond pulsars observed with INTEGRAL

    E-Print Network [OSTI]

    Maurizio Falanga

    2007-11-07

    I review the properties of three X-ray accreting millisecond pulsars observed with INTEGRAL. Out of seven recently discovered accretion-powered pulsars (one discovered by INTEGRAL), three were observed with the INTEGRAL satellite up to 300 keV. Detailed timing and spectral results will be presented, including data obtained during the most recent outburst of the pulsar HETE J1900.1-2455. Accreting X-ray millisecond pulsars are key systems to understand the spin and accretion history of neutron stars. They are also a good laboratory in which to study the source spectra, pulse profile, and phase shift between X-ray pulses in different energy ranges which give additional information of the X-ray production processes and emission environment.

  9. Magnetically Confined Wind Shocks in X-rays - a Review

    E-Print Network [OSTI]

    ud-Doula, Asif

    2015-01-01

    A subset (~ 10%) of massive stars present strong, globally ordered (mostly dipolar) magnetic fields. The trapping and channeling of their stellar winds in closed magnetic loops leads to magnetically confined wind shocks (MCWS), with pre-shock flow speeds that are some fraction of the wind terminal speed. These shocks generate hot plasma, a source of X-rays. In the last decade, several developments took place, notably the determination of the hot plasma properties for a large sample of objects using XMM-Newton and Chandra, as well as fully self-consistent MHD modelling and the identification of shock retreat effects in weak winds. Despite a few exceptions, the combination of magnetic confinement, shock retreat and rotation effects seems to be able to account for X-ray emission in massive OB stars. Here we review these new observational and theoretical aspects of this X-ray emission and envisage some perspectives for the next generation of X-ray observatories.

  10. Systems and methods for detecting x-rays

    DOE Patents [OSTI]

    Bross, Alan D.; Mellott, Kerry L.; Pla-Dalmau, Anna

    2006-05-02

    Systems and methods for detecting x-rays are disclosed herein. One or more x-ray-sensitive scintillators can be configured from a plurality of heavy element nano-sized particles and a plastic material, such as polystyrene. As will be explained in greater detail herein, the heavy element nano-sized particles (e.g., PbWO4) can be compounded into the plastic material with at least one dopant that permits the plastic material to scintillate. X-rays interact with the heavy element nano-sized particles to produce electrons that can deposit energy in the x-ray sensitive scintillator, which in turn can produce light.

  11. X-ray obscuration in local Universe AGN

    E-Print Network [OSTI]

    Matteo Guainazzi

    2006-10-31

    I review the constraints that X-ray observations impose on the physical properties and the geometrical distribution of cold absorbing gas in nearby obscured Active Galactic Nuclei (AGN), as well as their implications for AGN structure models.

  12. Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    interpretation of XMLD data. Magnetism and X Rays The ancient Greeks and also the Chinese knew about strange and rare stones with the power to attract iron. Moreover, when...

  13. The Ulysses Catalog of Solar Hard X-Ray Flares

    E-Print Network [OSTI]

    Tranquille, C.; Hurley, K.; Hudson, H. S.

    2009-01-01

    Sturrock, P.A. (ed. ) Solar Flares: A Monograph from SkylabSmith E.V.P. : 1963, Solar Flares, Macmillan, New York.Catalog of Solar Hard X-Ray Flares Table 1 (Continued. )

  14. Using Light to Control How X Rays Interact with Matter

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Using Light to Control How X Rays Interact with Matter Print Schemes that use one light pulse to manipulate interactions of another with matter are well developed in the...

  15. X-Ray Propagation in Tapered Waveguides: Simulation and Optimization

    E-Print Network [OSTI]

    Peinke, Joachim

    [1,2]. X-ray waveguides (WG) have been designed and fabricated as planar layered systems (1D-WG) [3. The propagation in the stuctures is studied by numerical solution of the parabolic wave equation (PWE), as used

  16. Generation of Coherent X-Ray Radiation through Modulation Compression...

    Office of Scientific and Technical Information (OSTI)

    In this paper, we propose a scheme to generate tunable coherent X-ray radiation for future light source applications. This scheme uses an energy chirped electron beam, a laser...

  17. Towards attosecond X-ray pulses from the FEL

    E-Print Network [OSTI]

    Zholents, Alexander A.; Fawley, William M.

    2004-01-01

    can be used instead of HC FEL. In the following illustra-UM is now tuned for resonant FEL interaction with the 32-nmAttosecond X-Ray Pulses from the FEL Alexander A. Zholents,

  18. High performance x-ray anti-scatter grid

    DOE Patents [OSTI]

    Logan, C.M.

    1995-05-23

    Disclosed are an x-ray anti-scatter grid for x-ray imaging, particularly for screening mammography, and method for fabricating same, x-rays incident along a direct path pass through a grid composed of a plurality of parallel or crossed openings, microchannels, grooves, or slots etched in a substrate, such as silicon, having the walls of the microchannels or slots coated with a high opacity material, such as gold, while x-rays incident at angels with respect to the slots of the grid, arising from scatter, are blocked. The thickness of the substrate is dependent on the specific application of the grid, whereby a substrate of the grid for mammography would be thinner than one for chest radiology. Instead of coating the walls of the slots, such could be filed with an appropriate liquid, such as mercury. 4 Figs.

  19. Vitreous carbon mask substrate for X-ray lithography

    DOE Patents [OSTI]

    Aigeldinger, Georg (Livermore, CA); Skala, Dawn M. (Fremont, CA); Griffiths, Stewart K. (Livermore, CA); Talin, Albert Alec (Livermore, CA); Losey, Matthew W. (Livermore, CA); Yang, Chu-Yeu Peter (Dublin, CA)

    2009-10-27

    The present invention is directed to the use of vitreous carbon as a substrate material for providing masks for X-ray lithography. The new substrate also enables a small thickness of the mask absorber used to pattern the resist, and this enables improved mask accuracy. An alternative embodiment comprised the use of vitreous carbon as a LIGA substrate wherein the VC wafer blank is etched in a reactive ion plasma after which an X-ray resist is bonded. This surface treatment provides a surface enabling good adhesion of the X-ray photoresist and subsequent nucleation and adhesion of the electrodeposited metal for LIGA mold-making while the VC substrate practically eliminates secondary radiation effects that lead to delamination of the X-ray resist form the substrate, the loss of isolated resist features, and the formation of a resist layer adjacent to the substrate that is insoluble in the developer.

  20. High order reflectivity of graphite (HOPG) crystals for x ray...

    Office of Scientific and Technical Information (OSTI)

    (22.1 keV) x-rays, produced by petawatt class laser pulses interacting with a Kr gas jet and a silver foil, to measure the integrated crystal reflectivity of flat Highly...

  1. X-ray imaging reveals secrets in battery materials | Argonne...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    X-ray imaging reveals secrets in battery materials June 22, 2015 Tweet EmailPrint Imaging and data analysis techniques offer new approach to probing material properties In a new...

  2. Dose optimization in cardiac x-ray imaging

    SciTech Connect (OSTI)

    Gislason-Lee, Amber J.; McMillan, Catherine; Cowen, Arnold R.; Davies, Andrew G.

    2013-09-15

    Purpose: The aim of this research was to optimize x-ray image quality to dose ratios in the cardiac catheterization laboratory. This study examined independently the effects of peak x-ray tube voltage (kVp), copper (Cu), and gadolinium (Gd) x-ray beam filtration on the image quality to radiation dose balance for adult patient sizes.Methods: Image sequences of polymethyl methacrylate (PMMA) phantoms representing two adult patient sizes were captured using a modern flat panel detector based x-ray imaging system. Tin and copper test details were used to simulate iodine-based contrast medium and stents/guide wires respectively, which are used in clinical procedures. Noise measurement for a flat field image and test detail contrast were used to calculate the contrast to noise ratio (CNR). Entrance surface dose (ESD) and effective dose measurements were obtained to calculate the figure of merit (FOM), CNR{sup 2}/dose. This FOM determined the dose efficiency of x-ray spectra investigated. Images were captured with 0.0, 0.1, 0.25, 0.4, and 0.9 mm Cu filtration and with a range of gadolinium oxysulphide (Gd{sub 2}O{sub 2}S) filtration.Results: Optimum x-ray spectra were the same for the tin and copper test details. Lower peak tube voltages were generally favored. For the 20 cm phantom, using 2 Lanex Fast Back Gd{sub 2}O{sub 2}S screens as x-ray filtration at 65 kVp provided the highest FOM considering ESD and effective dose. Considering ESD, this FOM was only marginally larger than that from using 0.4 mm Cu at 65 kVp. For the 30 cm phantom, using 0.25 mm copper filtration at 80 kVp was most optimal; considering effective dose the FOM was highest with no filtration at 65 kVp.Conclusions: These settings, adjusted for x-ray tube loading limits and clinically acceptable image quality, should provide a useful option for optimizing patient dose to image quality in cardiac x-ray imaging. The same optimal x-ray beam spectra were found for both the tin and copper details, suggesting that iodine contrast based imaging and visualization of interventional devices could potentially be optimized for dose using similar x-ray beam spectra.

  3. X-ray tube with magnetic electron steering

    DOE Patents [OSTI]

    Reed, Kim W. (Albuquerque, NM); Turman, Bobby N. (Albuquerque, NM); Kaye, Ronald J. (Albuquerque, NM); Schneider, Larry X. (Albuquerque, NM)

    2000-01-01

    An X-ray tube uses a magnetic field to steer electrons. The magnetic field urges electrons toward the anode, increasing the proportion of electrons emitted from the cathode that reach desired portions of the anode and consequently contribute to X-ray production. The magnetic field also urges electrons reflected from the anode back to the anode, further increasing the efficiency of the tube.

  4. New Directions in X-Ray Light Sources

    ScienceCinema (OSTI)

    Falcone, Roger

    2010-01-08

    July 15, 2008 Berkeley Lab lecture: Molecular movies of chemical reactions and material phase transformations need a strobe of x-rays, the penetrating light that reveals how atoms and molecules assemble in chemical and biological systems and complex materials. Roger Falcone, Director of the Advanced Light Source,will discuss a new generation of x ray sources that will enable a new science of atomic dynamics on ultrafast timescales.

  5. New focusing multilayer structures for X-ray plasma spectroscopy

    SciTech Connect (OSTI)

    Bibishkin, M S; Luchin, V I; Salashchenko, N N; Chernov, V V; Chkhalo, N I; Kazakov, E D; Shevelko, A P

    2008-02-28

    New focusing short-period multilayer structures are developed which opens up wide possibilities for X-ray and VUV spectroscopy. Multilayer structures are deposited on a flat surface of a mica crystal which is then bent to a small-radius cylinder. The use of this structure in a von Hamos spectrometer for X-ray laser plasma diagnostics is demonstrated. (interaction of laser radiation with matter. laser plasma)

  6. Evaluation of partial coherence correction in X-ray ptychography

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Burdet, Nicolas; Shi, Xiaowen; Parks, Daniel; Clark, Jesse N.; Huang, Xiaojing; Kevan, Stephen D.; Robinson, Ian K.

    2015-02-23

    Coherent X-ray Diffraction Imaging (CDI) and X-ray ptychography both heavily rely on the high degree of spatial coherence of the X-ray illumination for sufficient experimental data quality for reconstruction convergence. Nevertheless, the majority of the available synchrotron undulator sources have a limited degree of partial coherence, leading to reduced data quality and a lower speckle contrast in the coherent diffraction patterns. It is still an open question whether experimentalists should compromise the coherence properties of an X-ray source in exchange for a higher flux density at a sample, especially when some materials of scientific interest are relatively weak scatterers. Amore »previous study has suggested that in CDI, the best strategy for the study of strong phase objects is to maintain a high degree of coherence of the illuminating X-rays because of the broadening of solution space resulting from the strong phase structures. In this article, we demonstrate the first systematic analysis of the effectiveness of partial coherence correction in ptychography as a function of the coherence properties, degree of complexity of illumination (degree of phase diversity of the probe) and sample phase complexity. We have also performed analysis of how well ptychographic algorithms refine X-ray probe and complex coherence functions when those variables are unknown at the start of reconstructions, for noise-free simulated data, in the case of both real-valued and highly-complex objects.« less

  7. Spectral Formation in X-Ray Pulsar Accretion Columns

    E-Print Network [OSTI]

    Peter A. Becker; Michael T. Wolff

    2005-03-03

    We present the first self-consistent model for the dynamics and the radiative transfer occurring in bright X-ray pulsar accretion columns, with a special focus on the role of the shock in energizing the emerging X-rays. The pressure inside the accretion column of a luminous X-ray pulsar is dominated by the photons, and consequently the equations describing the coupled radiative-dynamical structure must be solved simultaneously. Spectral formation in these sources is therefore a complex, nonlinear phenomenon. We obtain the analytical solution for the Green's function describing the upscattering of monochromatic radiation injected into the column from the thermal mound located near the base of the flow. The Green's function is convolved with a Planck distribution to model the X-ray spectrum resulting from the reprocessing of blackbody photons produced in the thermal mound. These photons diffuse through the infalling gas and eventually escape out the walls of the column, forming the observed X-ray spectrum. We show that the resulting column-integrated, phase-averaged spectrum has a power-law shape at high energies and a blackbody shape at low energies, in agreement with the observational data for many X-ray pulsars.

  8. A short working distance multiple crystal x-ray spectrometer

    SciTech Connect (OSTI)

    Dickinson, B.; Seidler, G. T.; Webb, Z. W.; Bradley, J. A.; Nagle, K. P. [Department of Physics, University of Washington, Seattle, Washington 98195 (United States); Heald, S. M. [Advanced Photon Source, Argonne National Laboratories, Argonne, Illinois 60439 (United States); Gordon, R. A. [Department of Physics, Simon Fraser University, Burnaby, British Columbia V5A 1S6 (Canada); Chou, I. M. [U.S. Geological Survey, Reston, Virginia 20192 (United States)

    2008-12-15

    For x-ray spot sizes of a few tens of microns or smaller, a millimeter-sized flat analyzer crystal placed {approx}1 cm from the sample will exhibit high energy resolution while subtending a collection solid angle comparable to that of a typical spherically bent crystal analyzer (SBCA) at much larger working distances. Based on this observation and a nonfocusing geometry for the analyzer optic, we have constructed and tested a short working distance (SWD) multicrystal x-ray spectrometer. This prototype instrument has a maximum effective collection solid angle of 0.14 sr, comparable to that of 17 SBCA at 1 m working distance. We find good agreement with prior work for measurements of the Mn K{beta} x-ray emission and resonant inelastic x-ray scattering for MnO, and also for measurements of the x-ray absorption near-edge structure for Dy metal using L{alpha}{sub 2} partial-fluorescence yield detection. We discuss future applications at third- and fourth-generation light sources. For concentrated samples, the extremely large collection angle of SWD spectrometers will permit collection of high-resolution x-ray emission spectra with a single pulse of the Linac Coherent Light Source. The range of applications of SWD spectrometers and traditional multi-SBCA instruments has some overlap, but also is significantly complementary.

  9. The ASTRO-H X-ray Observatory

    E-Print Network [OSTI]

    Takahashi, Tadayuki; Kelley, Richard; Aharonian, Henri AartsFelix; Akamatsu, Hiroki; Akimoto, Fumie; Allen, Steve; Anabuki, Naohisa; Angelini, Lorella; Arnaud, Keith; Asai, Makoto; Audard, Marc; Awaki, Hisamitsu; Azzarello, Philipp; Baluta, Chris; Bamba, Aya; Bando, Nobutaka; Bautz, Mark; Blandford, Roger; Boyce, Kevin; Brown, Greg; Cackett, Ed; Chernyakova, Maria; Coppi, Paolo; Costantini, Elisa; de Plaa, Jelle; Herder, Jan-Willem den; DiPirro, Michael; Done, Chris; Dotani, Tadayasu; Doty, John; Ebisawa, Ken; Eckart, Megan; Enoto, Teruaki; Ezoe, Yuichiro; Fabian, Andrew; Ferrigno, Carlo; Foster, Adam; Fujimoto, Ryuichi; Fukazawa, Yasushi; Funk, Stefan; Furuzawa, Akihiro; Galeazzi, Massimiliano; Gallo, Luigi; Gandhi, Poshak; Gendreau, Keith; Gilmore, Kirk; Haas, Daniel; Haba, Yoshito; Hamaguchi, Kenji; Hatsukade, Isamu; Hayashi, Takayuki; Hayashida, Kiyoshi; Hiraga, Junko; Hirose, Kazuyuki; Hornschemeier, Ann; Hoshino, Akio; Hughes, John; Hwang, Una; Iizuka, Ryo; Inoue, Yoshiyuki; Ishibashi, Kazunori; Ishida, Manabu; Ishimura, Kosei; Ishisaki, Yoshitaka; Ito, Masayuki; Iwata, Naoko; Iyomoto, Naoko; Kaastra, Jelle; Kallman, Timothy; Kamae, Tuneyoshi; Kataoka, Jun; Katsuda, Satoru; Kawahara, Hajime; Kawaharada, Madoka; Kawai, Nobuyuki; Kawasaki, Shigeo; Khangaluyan, Dmitry; Kilbourne, Caroline; Kimura, Masashi; Kinugasa, Kenzo; Kitamoto, Shunji; Kitayama, Tetsu; Kohmura, Takayoshi; Kokubun, Motohide; Kosaka, Tatsuro; Koujelev, Alex; Koyama, Katsuji; Krimm, Hans; Kubota, Aya; Kunieda, Hideyo; LaMassa, Stephanie; Laurent, Philippe; Lebrun, Francois; Leutenegger, Maurice; Limousin, Olivier; Loewenstein, Michael; Long, Knox; Lumb, David; Madejski, Grzegorz; Maeda, Yoshitomo; Makishima, Kazuo; Marchand, Genevieve; Markevitch, Maxim; Matsumoto, Hironori; Matsushita, Kyoko; McCammon, Dan; McNamara, Brian; Miller, Jon; Miller, Eric; Mineshige, Shin; Minesugi, Kenji; Mitsuishi, Ikuyuki; Miyazawa, Takuya; Mizuno, Tsunefumi; Mori, Hideyuki; Mori, Koji; Mukai, Koji; Murakami, Toshio; Murakami, Hiroshi; Mushotzky, Richard; Nagano, Housei; Nagino, Ryo; Nakagawa, Takao; Nakajima, Hiroshi; Nakamori, Takeshi; Nakazawa, Kazuhiro; Namba, Yoshiharu; Natsukari, Chikara; Nishioka, Yusuke; Nobukawa, Masayoshi; Nomachi, Masaharu; Dell, Steve O'; Odaka, Hirokazu; Ogawa, Hiroyuki; Ogawa, Mina; Ogi, Keiji; Ohashi, Takaya; Ohno, Masanori; Ohta, Masayuki; Okajima, Takashi; Okamoto, Atsushi; Okazaki, Tsuyoshi; Ota, Naomi; Ozaki, Masanobu; Paerels, Frits; Paltani, Stephane; Parmar, Arvind; Petre, Robert; Pohl, Martin; Porter, F Scott; Ramsey, Brian; Reis, Rubens; Reynolds, Christopher; Russell, Helen; Safi-Harb, Samar; Sakai, Shin-ichiro; Sameshima, Hiroaki; Sanders, Jeremy; Sato, Goro; Sato, Rie; Sato, Yoichi; Sato, Kosuke; Sawada, Makoto; Serlemitsos, Peter; Seta, Hiromi; Shibano, Yasuko; Shida, Maki; Shimada, Takanobu; Shinozaki, Keisuke; Shirron, Peter; Simionescu, Aurora; Simmons, Cynthia; Smith, Randall; Sneiderman, Gary; Soong, Yang; Stawarz, Lukasz; Sugawara, Yasuharu; Sugita, Hiroyuki; Sugita, Satoshi; Szymkowiak, Andrew; Tajima, Hiroyasu; Takahashi, Hiromitsu; Takeda, Shin-ichiro; Takei, Yoh; Tamagawa, Toru; Tamura, Takayuki; Tamura, Keisuke; Tanaka, Takaaki; Tanaka, Yasuo; Tashiro, Makoto; Tawara, Yuzuru; Terada, Yukikatsu; Terashima, Yuichi; Tombesi, Francesco; Tomida, Hiroshi; Tsuboi, Yoko; Tsujimoto, Masahiro; Tsunemi, Hiroshi; Tsuru, Takeshi; Uchida, Hiroyuki; Uchiyama, Yasunobu; Uchiyama, Hideki; Ueda, Yoshihiro; Ueno, Shiro; Uno, Shinichiro; Urry, Meg; Ursino, Eugenio; de Vries, Cor; Wada, Atsushi; Watanabe, Shin; Werner, Norbert; White, Nicholas; Yamada, Takahiro; Yamada, Shinya; Yamaguchi, Hiroya; Yamasaki, Noriko; Yamauchi, Shigeo; Yamauchi, Makoto; Yatsu, Yoichi; Yonetoku, Daisuke; Yoshida, Atsumasa; Yuasa, Takayuki

    2012-01-01

    The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV. These instruments include a high-resolution, high-throughput spectrometer sensitive over 0.3-2 keV with high spectral resolution of Delta E < 7 eV, enabled by a micro-calorimeter array located in the focal plane of thin-foil X-ray optics; hard X-ray imaging spectrometers covering 5-80 keV, located in the focal plane of multilayer-coated, focusing hard X-ray mirrors; a wide-field imaging spectrometer sensitive over 0.4-12 keV, with an X-ray CCD camera in the focal plane of a soft X-ray telescope; and a non-focusing Compton-camera type soft gamma-ray detector, sensitive in the 40-600 keV band. The simultaneous broad bandpass, coupled with high spectral resolution, will enable the pursuit o...

  10. X-rays from protostellar jets: emission from continuous flows

    E-Print Network [OSTI]

    R. Bonito; S. Orlando; G. Peres; F. Favata; R. Rosner

    2006-10-17

    Recently X-ray emission from protostellar jets has been detected with both XMM-Newton and Chandra satellites, but the physical mechanism which can give rise to this emission is still unclear. We performed an extensive exploration of a wide space of the main parameters influencing the jet/ambient interaction. Aims include: 1) to constrain the jet/ambient interaction regimes leading to the X-ray emission observed in Herbig-Haro objects in terms of the emission by a shock forming at the interaction front between a continuous supersonic jet and the surrounding medium; 2) to derive detailed predictions to be compared with optical and X-ray observations of protostellar jets; 3) to get insight into the protostellar jet's physical conditions. We performed a set of bidimensional hydrodynamic numerical simulations, in cylindrical coordinates, modeling supersonic jets ramming a uniform ambient medium. The model takes into account the most relevant physical effects, namely the thermal conduction and the radiative losses. Our model explains the observed X-ray emission from protostellar jets in a natural way. In particular we find that the case of a protostellar jet less dense than the ambient medium reproduces well the observations of the nearest Herbig-Haro object, HH154, and allows us to make detailed predictions of a possible X-ray source proper motion (vsh = 500 km/s), detectable with Chandra. Furthermore our results suggest that the simulated protostellar jets which best reproduce the X-rays observations cannot drive molecular outflows.

  11. Ultraviolet germicidal irradiation and its effects on elemental distributions in mouse embryonic fibroblast cells in x-ray fluorescence microanalysis

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Jin, Qiaoling; Vogt, Stefan; Lai, Barry; Chen, Si; Finney, Lydia; Gleber, Sophie-Charlotte; Ward, Jesse; Deng, Junjing; Mak, Rachel; Moonier, Nena; et al

    2015-02-23

    Rapidly-frozen hydrated (cryopreserved) specimens combined with cryo-scanning x-ray fluorescence microscopy provide an ideal approach for investigating elemental distributions in biological cells and tissues. However, because cryopreservation does not deactivate potentially infectious agents associated with Risk Group 2 biological materials, one must be concerned with contamination of expensive and complicated cryogenic x-ray microscopes when working with such materials. We employed ultraviolet germicidal irradiation to decontaminate previously cryopreserved cells under liquid nitrogen, and then investigated its effects on elemental distributions under both frozen hydrated and freeze dried states with x-ray fluorescence microscopy. We show that the contents and distributions of most biologicallymore »important elements remain nearly unchanged when compared with non-ultraviolet-irradiated counterparts, even after multiple cycles of ultraviolet germicidal irradiation and cryogenic x-ray imaging. This provides a potential pathway for rendering Risk Group 2 biological materials safe for handling in multiuser cryogenic x-ray microscopes without affecting the fidelity of the results.« less

  12. Ultraviolet germicidal irradiation and its effects on elemental distributions in mouse embryonic fibroblast cells in x-ray fluorescence microanalysis

    SciTech Connect (OSTI)

    Jin, Qiaoling; Vogt, Stefan; Lai, Barry; Chen, Si; Finney, Lydia; Gleber, Sophie-Charlotte; Ward, Jesse; Deng, Junjing; Mak, Rachel; Moonier, Nena; Jacobsen, Chris; Brody, James P.

    2015-02-23

    Rapidly-frozen hydrated (cryopreserved) specimens combined with cryo-scanning x-ray fluorescence microscopy provide an ideal approach for investigating elemental distributions in biological cells and tissues. However, because cryopreservation does not deactivate potentially infectious agents associated with Risk Group 2 biological materials, one must be concerned with contamination of expensive and complicated cryogenic x-ray microscopes when working with such materials. We employed ultraviolet germicidal irradiation to decontaminate previously cryopreserved cells under liquid nitrogen, and then investigated its effects on elemental distributions under both frozen hydrated and freeze dried states with x-ray fluorescence microscopy. We show that the contents and distributions of most biologically important elements remain nearly unchanged when compared with non-ultraviolet-irradiated counterparts, even after multiple cycles of ultraviolet germicidal irradiation and cryogenic x-ray imaging. This provides a potential pathway for rendering Risk Group 2 biological materials safe for handling in multiuser cryogenic x-ray microscopes without affecting the fidelity of the results.

  13. HIgh Rate X-ray Fluorescence Detector

    SciTech Connect (OSTI)

    Grudberg, Peter Matthew [XIA LLC

    2013-04-30

    The purpose of this project was to develop a compact, modular multi-channel x-ray detector with integrated electronics. This detector, based upon emerging silicon drift detector (SDD) technology, will be capable of high data rate operation superior to the current state of the art offered by high purity germanium (HPGe) detectors, without the need for liquid nitrogen. In addition, by integrating the processing electronics inside the detector housing, the detector performance will be much less affected by the typically noisy electrical environment of a synchrotron hutch, and will also be much more compact than current systems, which can include a detector involving a large LN2 dewar and multiple racks of electronics. The combined detector/processor system is designed to match or exceed the performance and features of currently available detector systems, at a lower cost and with more ease of use due to the small size of the detector. In addition, the detector system is designed to be modular, so a small system might just have one detector module, while a larger system can have many â?? you can start with one detector module, and add more as needs grow and budget allows. The modular nature also serves to simplify repair. In large part, we were successful in achieving our goals. We did develop a very high performance, large area multi-channel SDD detector, packaged with all associated electronics, which is easy to use and requires minimal external support (a simple power supply module and a closed-loop water cooling system). However, we did fall short of some of our stated goals. We had intended to base the detector on modular, large-area detectors from Ketek GmbH in Munich, Germany; however, these were not available in a suitable time frame for this project, so we worked instead with pnDetector GmbH (also located in Munich). They were able to provide a front-end detector module with six 100 m^2 SDD detectors (two monolithic arrays of three elements each) along with associated preamplifiers; these detectors surpassed the performance we expected to get from the Ketek detectors, however they are housed in a sealed module, which does not offer the ease of repair and expandability weâ??d hoped to achieve with the Ketek SDDâ??s. Our packaging efforts were quite successful, as we came up with a very compact way to mount the detector and to house the associated electronics, as well as a very effective way to reliably take out the heat (from the electronics as well as the detectorâ??s Peltier coolers) without risk of condensation and without external airflow or vibration, which could create problems for the target applications. While we were able to design compact processing electronics that fit into the detector assembly, they are still at the prototype stage, and would require a significant redesign to achieve product status. We have not yet tested this detector at a synchrotron facility; we do still plan on working with some close contacts at the nearby Stanford Synchrotron Radiation Laboratory (SSRL) to get some testing with the beam (using existing commercial electronics for readout, as the integrated processor is not ready for use).

  14. X-RAY EMISSION FROM MAGNETIC MASSIVE STARS

    SciTech Connect (OSTI)

    Nazé, Yaël; Petit, Véronique; Rinbrand, Melanie; Owocki, Stan; Cohen, David; Ud-Doula, Asif; Wade, Gregg A.

    2014-11-01

    Magnetically confined winds of early-type stars are expected to be sources of bright and hard X-rays. To clarify the systematics of the observed X-ray properties, we have analyzed a large series of Chandra and XMM-Newton observations, corresponding to all available exposures of known massive magnetic stars (over 100 exposures covering ?60% of stars compiled in the catalog of Petit et al.). We show that the X-ray luminosity is strongly correlated with the stellar wind mass-loss rate, with a power-law form that is slightly steeper than linear for the majority of the less luminous, lower- M-dot B stars and flattens for the more luminous, higher- M-dot O stars. As the winds are radiatively driven, these scalings can be equivalently written as relations with the bolometric luminosity. The observed X-ray luminosities, and their trend with mass-loss rates, are well reproduced by new MHD models, although a few overluminous stars (mostly rapidly rotating objects) exist. No relation is found between other X-ray properties (plasma temperature, absorption) and stellar or magnetic parameters, contrary to expectations (e.g., higher temperature for stronger mass-loss rate). This suggests that the main driver for the plasma properties is different from the main determinant of the X-ray luminosity. Finally, variations of the X-ray hardnesses and luminosities, in phase with the stellar rotation period, are detected for some objects and they suggest that some temperature stratification exists in massive stars' magnetospheres.

  15. Water destruction by X-rays in young stellar objects

    E-Print Network [OSTI]

    P. Stauber; J. K. Jorgensen; E. F. van Dishoeck; S. D. Doty; A. O. Benz

    2006-02-06

    We study the H2O chemistry in star-forming environments under the influence of a central X-ray source and a central far ultraviolet (FUV) radiation field. The gas-phase water chemistry is modeled as a function of time, hydrogen density and X-ray flux. To cover a wide range of physical environments, densities between n_H = 10^4-10^9 cm^-3 and temperatures between T = 10-1000 K are studied. Three different regimes are found: For T water abundance is of order 10^-7-10^-6 and can be somewhat enhanced or reduced due to X-rays, depending on time and density. For 100 K 10^-3 ergs s-1 cm^-2 (t = 10^4 yrs) and for F_X > 10^-4 ergs s^-1 cm^-2 (t = 10^5 yrs). At higher temperatures (T > 250 K) and hydrogen densities, water can persist with x(H2O) ~ 10^-4 even for high X-ray fluxes. The X-ray and FUV models are applied to envelopes around low-mass Class 0 and I young stellar objects (YSOs). Water is destroyed in both Class 0 and I envelopes on relatively short timescales (t ~ 5000 yrs) for realistic X-ray fluxes, although the effect is less prominent in Class 0 envelopes due to the higher X-ray absorbing densities there. FUV photons from the central source are not effective in destroying water. The average water abundance in Class I sources for L_X > 10^27 ergs s^-1 is predicted to be x(H2O) < 10^-6.

  16. X-ray emitting young stars in the Orion Nebula

    E-Print Network [OSTI]

    Eric D. Feigelson; Patrick Broos; James A. Gaffney III; Gordon Garmire; Lynne A. Hillenbrand; Steven H. Pravdo; Leisa Townsley; Yohko Tsuboi

    2002-03-19

    The Orion Nebula Cluster and the molecular cloud in its vicinity have been observed with the ACIS-I detector on board the Chandra X-ray Observatory with 23 hours exposure. We detect 1075 X-ray sources: 91% are spatially associated with known stellar members of the cluster, and 7% are newly identified deeply embedded cloud members. This provides the largest X-ray study of a pre-main sequence stellar population. We examine here the X-ray properties of Orion young stars as a function of mass. Results include: (a) the discovery of rapid variability in the O9.5 31 M_o star \\theta^2A Ori, and several early B stars, inconsistent with the standard model of X-ray production in small wind shocks; (b) support for the hypothesis that intermediate-mass mid-B through A type stars do not themselves produce significant X-ray emission; (c) confirmation that low-mass G- through M-type T Tauri stars exhibit powerful flaring but typically at luminosities considerably below the `saturation' level; (d) confirmation that the presence or absence of a circumstellar disk has no discernable effect on X-ray emission; (e) evidence that T Tauri plasma temperatures are often very high with T >= 100 MK, even when luminosities are modest and flaring is not evident; and (f) detection of the largest sample of pre-main sequence very low mass objects showing high flaring levels and a decline in magnetic activity as they evolve into L- and T-type brown dwarfs.

  17. Predicting X-ray diffuse scattering from translation–libration–screw structural ensembles

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Van Benschoten, Andrew H.; Afonine, Pavel V.; Terwilliger, Thomas C.; Wall, Michael E.; Jackson, Colin J.; Sauter, Nicholas K.; Adams, Paul D.; Urzhumtsev, Alexandre; Fraser, James S.

    2015-07-28

    Identifying the intramolecular motions of proteins and nucleic acids is a major challenge in macromolecular X-ray crystallography. Because Bragg diffraction describes the average positional distribution of crystalline atoms with imperfect precision, the resulting electron density can be compatible with multiple models of motion. Diffuse X-ray scattering can reduce this degeneracy by reporting on correlated atomic displacements. Although recent technological advances are increasing the potential to accurately measure diffuse scattering, computational modeling and validation tools are still needed to quantify the agreement between experimental data and different parameterizations of crystalline disorder. A new tool, phenix.diffuse, addresses this need by employing Guinier'smore »equation to calculate diffuse scattering from Protein Data Bank (PDB)-formatted structural ensembles. As an example case, phenix.diffuse is applied to translation–libration–screw (TLS) refinement, which models rigid-body displacement for segments of the macromolecule. To enable the calculation of diffuse scattering from TLS-refined structures, phenix.tls_as_xyz builds multi-model PDB files that sample the underlying T, L and S tensors. In the glycerophosphodiesterase GpdQ, alternative TLS-group partitioning and different motional correlations between groups yield markedly dissimilar diffuse scattering maps with distinct implications for molecular mechanism and allostery. These methods demonstrate how, in principle, X-ray diffuse scattering could extend macromolecular structural refinement, validation and analysis.« less

  18. High-energy x-ray production with pyroelectric crystals Jeffrey A. Geuthera

    E-Print Network [OSTI]

    Danon, Yaron

    High-energy x-ray production with pyroelectric crystals Jeffrey A. Geuthera and Yaron Danon, the usefulness of an x-ray source is determined by its yield and endpoint energy. In x-ray fluorescence, for example, high-energy sources enable the excitation of the K-shell x-ray peaks for high-Z materials as well

  19. Tools for a Theoretical X-ray Beamline J. J. Rehr*

    E-Print Network [OSTI]

    Botti, Silvana

    Tools for a Theoretical X-ray Beamline J. J. Rehr* Department of Physics University of Washington, France 22 October 2010 #12;X-ray Spectroscopy Beamline #12;Tools for a Theoretical X-ray Beamline · GOAL Theoretical X-ray Beamline: 2. Tools for EXAFS and XANES, EELS, XMCD, ... 3. DFT/MD-TOOLS 4. Next generation

  20. Chemical Shifts in X-ray and Photo-Electron Spectroscopy: A Historical review

    E-Print Network [OSTI]

    Lindgren, Ingvar

    Chemical Shifts in X-ray and Photo-Electron Spectroscopy: A Historical review Ingvar Lindgren 1 Introduction 2 2 Chemical shift in X-ray spectroscopy 2 2.1 Discovery of the chemical shift in X-ray spectroscopy . . . . . . . . . . . . . 3 2.2 Interpretation of the chemical shift in X-ray spectroscopy

  1. Study of Interactions Between Microbes and Minerals by Scanning Transmission X-Ray Microscopy (STXM)

    E-Print Network [OSTI]

    Benzerara, K; Tyliszczak, T

    2007-01-01

    Study of Interactions Between Microbes and Minerals by Scanning Transmission X-Ray Microscopy (STXM)

  2. X-Ray Diagnostics for the Levitated Dipole Jennifer L. Ellsworth

    E-Print Network [OSTI]

    to utilize two x-ray diagnostics. An x-ray pulse height analyzer will measure the energy spectrum will be discussed. The x-ray pulse height analyzer and x-ray camera are vital to analyzing the first plasmas acquisition and electronics . . . . . . . . . . . . . . . . . 29 3.3.3 DXP4C2X Multichannel Analyzer Camac

  3. Scanning Transmission X-ray Microscopy: Applications in Atmospheric Aerosol Research

    E-Print Network [OSTI]

    Moffet, Ryan C.

    2011-01-01

    polymer photoresists by scanning transmission x-ray microscopy. Journal of Vacuum Science and Technology

  4. A Study of the Populations of X-ray Sources in the Small Magellanic Cloud with ASCA

    E-Print Network [OSTI]

    Jun Yokogawa; Kensuke Imanishi; Masahiro Tsujimoto; Mamiko Nishiuchi; Katsuji Koyama; Fumiaki Nagase; Robin H. D. Corbet

    2000-02-08

    The Advanced Satellite for Cosmology and Astrophysics (ASCA) has made multiple observations of the Small Magellanic Cloud (SMC). X-ray mosaic images in the soft (0.7--2.0 keV) and hard (2.0--7.0 keV) bands are separately constructed, and the latter provides the first hard X-ray view of the SMC. We extract 39 sources from the two-band images with a criterion of S/N>5, and conduct timing and spectral analyses for all of these sources. Coherent pulsations are detected from 12 X-ray sources; five of which are new discoveries. Most of the 12 X-ray pulsars are found to exhibit long-term flux variabilities, hence they are likely to be X-ray binary pulsars (XBPs). On the other hand, we classify four supernova remnants (SNRs) as thermal SNRs, because their spectra exhibit emission lines from highly ionized atoms. We find that XBPs and thermal SNRs in the SMC can be clearly separated by their hardness ratio (the ratio of the count rate between the hard and soft bands). Using this empirical grouping, we find many XBP candidates in the SMC, although no pulsations have yet been detected from these sources. Possible implications on the star-formation history and evolution of the SMC are presented by a comparison of the source populations in the SMC and our Galaxy.

  5. LOFT: the Large Observatory For X-ray Timing

    E-Print Network [OSTI]

    Belloni, Tomaso M

    2012-01-01

    LOFT, the large observatory for X-ray timing, is a new mission concept competing with other four candidates for a launch opportunity in 2022-2024. LOFT will be performing high-time resolution X-ray observations of compact objects, combining for the first time an unprecedented large collecting area for X-ray photons and a spectral resolution approaching that of CCD-based X-ray instruments (down to 200 eV FWHM at 6 keV). The operating energy range is 2-80 keV. The main science goals of LOFT are the measurement of the neutron stars equation of states and the test of General Relativity in the strong field regime. The breakthrough capabilities of the instruments on-board LOFT will permit to open also new discovery windows for a wide range of Galactic and extragalactic X-ray sources. In this contribution, we provide a general description of the mission concept and summarize its main scientific capabilities.

  6. The History of X-ray Free-Electron Lasers

    SciTech Connect (OSTI)

    Pellegrini, C.; ,

    2012-06-28

    The successful lasing at the SLAC National Accelerator Laboratory of the Linear Coherent Light Source (LCLS), the first X-ray free-electron laser (X-ray FEL), in the wavelength range 1.5 to 15 {angstrom}, pulse duration of 60 to few femtoseconds, number of coherent photons per pulse from 10{sup 13} to 10{sup 11}, is a landmark event in the development of coherent electromagnetic radiation sources. Until now electrons traversing an undulator magnet in a synchrotron radiation storage ring provided the best X-ray sources. The LCLS has set a new standard, with a peak X-ray brightness higher by ten orders of magnitudes and pulse duration shorter by three orders of magnitudes. LCLS opens a new window in the exploration of matter at the atomic and molecular scales of length and time. Taking a motion picture of chemical processes in a few femtoseconds or less, unraveling the structure and dynamics of complex molecular systems, like proteins, are some of the exciting experiments made possible by LCLS and the other X-ray FELs now being built in Europe and Asia. In this paper, we describe the history of the many theoretical, experimental and technological discoveries and innovations, starting from the 1960s and 1970s, leading to the development of LCLS.

  7. Viewing spin structures with soft x-ray microscopy

    SciTech Connect (OSTI)

    Fischer, Peter

    2010-06-01

    The spin of the electron and its associated magnetic moment marks the basic unit for magnetic properties of matter. Magnetism, in particular ferromagnetism and antiferromagnetism is described by a collective order of these spins, where the interaction between individual spins reflects a competition between exchange, anisotropy and dipolar energy terms. As a result the energetically favored ground state of a ferromagnetic system is a rather complex spin configuration, the magnetic domain structure. Magnetism is one of the eldest scientific phenomena, yet it is one of the most powerful and versatile utilized physical effects in modern technologies, such as in magnetic storage and sensor devices. To achieve highest storage density, the relevant length scales, such as the bit size in disk drives is now approaching the nanoscale and as such further developments have to deal with nanoscience phenomena. Advanced characterization tools are required to fully understand the underlying physical principles. Magnetic microscopes using polarized soft X-rays offer a close-up view into magnetism with unique features, these include elemental sensitivity due to X-ray magnetic dichroism effects as contrast mechanism, high spatial resolution provided by state-of-the-art X-ray optics and fast time resolution limited by the inherent time structure of current X-ray sources, which will be overcome with the introduction of ultrafast and high brilliant X-ray sources.

  8. Method and apparatus for micromachining using hard X-rays

    DOE Patents [OSTI]

    Siddons, D.P.; Johnson, E.D.; Guckel, H.; Klein, J.L.

    1997-10-21

    An X-ray source such as a synchrotron which provides a significant spectral content of hard X-rays is used to expose relatively thick photoresist such that the portions of the photoresist at an exit surface receive at least a threshold dose sufficient to render the photoresist susceptible to a developer, while the entrance surface of the photoresist receives an exposure which does not exceed a power limit at which destructive disruption of the photoresist would occur. The X-ray beam is spectrally shaped to substantially eliminate lower energy photons while allowing a substantial flux of higher energy photons to pass through to the photoresist target. Filters and the substrate of the X-ray mask may be used to spectrally shape the X-ray beam. Machining of photoresists such as polymethylmethacrylate to micron tolerances may be obtained to depths of several centimeters, and multiple targets may be exposed simultaneously. The photoresist target may be rotated and/or translated in the beam to form solids of rotation and other complex three-dimensional structures. 21 figs.

  9. Method and apparatus for micromachining using hard X-rays

    DOE Patents [OSTI]

    Siddons, David Peter (Shoreham, NY); Johnson, Erik D. (Ridge, NY); Guckel, Henry (Madison, WI); Klein, Jonathan L. (Madison, WI)

    1997-10-21

    An X-ray source such as a synchrotron which provides a significant spectral content of hard X-rays is used to expose relatively thick photoresist such that the portions of the photoresist at an exit surface receive at least a threshold dose sufficient to render the photoresist susceptible to a developer, while the entrance surface of the photoresist receives an exposure which does not exceed a power limit at which destructive disruption of the photoresist would occur. The X-ray beam is spectrally shaped to substantially eliminate lower energy photons while allowing a substantial flux of higher energy photons to pass through to the photoresist target. Filters and the substrate of the X-ray mask may be used to spectrally shape the X-ray beam. Machining of photoresists such as polymethylmethacrylate to micron tolerances may be obtained to depths of several centimeters, and multiple targets may be exposed simultaneously. The photoresist target may be rotated and/or translated in the beam to form solids of rotation and other complex three-dimensional structures.

  10. Correlated X-ray/Ultraviolet/Optical Variability in NGC 6814

    E-Print Network [OSTI]

    Troyer, Jon; Cackett, Edward; Bentz, Misty; Goad, Michael; Horne, Keith; Seals, James

    2015-01-01

    We present results of a 3-month combined X-ray/UV/optical monitoring campaign of the Seyfert 1 galaxy NGC 6814. The object was monitored by Swift from June through August 2012 in the X-ray and UV bands and by the Liverpool Telescope from May through July 2012 in B and V. The light curves are variable and significantly correlated between wavebands. Using cross-correlation analysis, we compute the time lag between the X-ray and lower energy bands. These lags are thought to be associated with the light travel time between the central X-ray emitting region and areas further out on the accretion disc. The computed lags support a thermal reprocessing scenario in which X-ray photons heat the disc and are reprocessed into lower energy photons. Additionally, we fit the lightcurves using CREAM, a Markov Chain Monte Carlo code for a standard disc. The best-fitting standard disc model yields unreasonably high super-Eddington accretion rates. Assuming more reasonable accretion rates would result in significantly under-pre...

  11. ON THE X-RAY OUTBURSTS OF TRANSIENT ANOMALOUS X-RAY PULSARS AND SOFT GAMMA-RAY REPEATERS

    SciTech Connect (OSTI)

    Cal Latin-Small-Letter-Dotless-I skan, Sirin; Ertan, Uenal [Sabanc Latin-Small-Letter-Dotless-I University, Orhanl Latin-Small-Letter-Dotless-I -Tuzla, Istanbul, 34956 (Turkey)

    2012-10-20

    We show that the X-ray outburst light curves of four transient anomalous X-ray pulsars (AXPs) and soft gamma-ray repeaters (SGRs), namely, XTE J1810-197, SGR 0501+4516, SGR 1627-41, and CXOU J164710.2-455216, can be produced by the fallback disk model that was also applied to the outburst light curves of persistent AXPs and SGRs in our earlier work. The model solves the diffusion equation for the relaxation of a disk that has been pushed back by a soft gamma-ray burst. The sets of main disk parameters used for these transient sources are very similar to each other and to those employed in our earlier models of persistent AXPs and SGRs. There is a characteristic difference between the X-ray outburst light curves of transient and persistent sources. This can be explained by the differences in the disk surface density profiles of the transient and persistent sources in quiescence indicated by their quiescent X-ray luminosities. Our results imply that a viscous disk instability operating at a critical temperature in the range of {approx}1300-2800 K is a common property of all fallback disks around AXPs and SGRs. The effect of the instability is more pronounced and starts earlier for the sources with lower quiescent luminosities, which leads to the observable differences in the X-ray enhancement light curves of transient and persistent sources. A single active disk model with the same basic disk parameters can account for the enhancement phases of both transient and persistent AXPs and SGRs. We also present a detailed parameter study to show the effects of disk parameters on the evolution of the X-ray luminosity of AXPs and SGRs in the X-ray enhancement phases.

  12. Hard X-rays from Emission Line Galaxies and the X-ray Background: A Test for Advection Dominated Accretion with Radio Sources

    E-Print Network [OSTI]

    Insu Yi; Stephen P. Boughn

    1997-10-14

    Recent studies of the cosmic X-ray background (XRB) have suggested the possible existence of a population of relatively faint sources with hard X-ray spectra; however, the emission mechanism remains unclear. If the hard X-ray emission is from the radiatively inefficient, advection dominated accretion flows (ADAFs) around massive black holes in galactic nuclei, X-ray luminosity and radio luminosity satisfy the approximate relation $L_R\\sim 7\\times 10^{35}(\

  13. Archaeometrical studies using X-ray fluorescence methods

    SciTech Connect (OSTI)

    Pauna, Catalina; Constantinescu, B.; Constantin, F.; Bugoi, R.; Stan, D.; Vasilescu, A. [National Institute of Nuclear Physics and Engineering, POB MG-6, 077125, Bucharest (Romania)

    2010-04-26

    Elemental analysis contributes to authentication (knowing the elemental composition and considering the information about the usual composition of the objects in different historical periods it can be established if the item is original or fake), provenance studies (minor and trace elements indicates ores origin and 'consequently' mines location), (relative) dating of archaeological objects (e.g. for painted items--the chemical recipes for pigments can offer information about the age of objects). The paper gives a general layout for the NIPNE Archaeometry Laboratory's applications using X-Ray Fluorescence (XRF), micro--Proton Induced X-Ray Emission (micro-PIXE), micro-Synchrotron Radiation Induced X-Ray Fluorescence (micro--SR-XRF) methods.

  14. The Large Observatory For X-ray Timing: LOFT

    E-Print Network [OSTI]

    Bozzo, E

    2013-01-01

    LOFT, the Large Observatory for X-ray Timing, is a new space mission concept devoted to observations of Galactic and extra-Galactic sources in the X-ray domain with the main goals of probing gravity theory in the very strong field environment of black holes and other compact objects, and investigating the state of matter at supra-nuclear densities in neutron stars. The instruments on-board LOFT, the Large area detector and the Wide Field Monitor combine for the first time an unprecedented large effective area (~10 m2 at 8 keV) sensitive to X-ray photons mainly in the 2-30 keV energy range and a spectral resolution approaching that of CCD-based telescopes (down to 200 eV at 6 keV). LOFT is currently competing for a launch of opportunity in 2022 together with the other M3 mission candidates of the ESA Cosmic Vision Program.

  15. Eta Car and Its Surroundings: the X-ray Diagnosis

    E-Print Network [OSTI]

    M. F. Corcoran; K. Hamaguchi

    2007-03-02

    X-ray emission from the supermassive star Eta Carinae (\\ec) originates from hot shocked gas produced by current stellar mass loss as well as ejecta from prior eruptive events. Absorption of this emission by cool material allows the determination of the spatial and temporal distribution of this material. Emission from the shocked gas can provide important information about abundances through the study of thermal X-ray line emission. We discuss how studies of the X-ray emission from Eta Car at a variety of temporal, spatial and spectral scales and resolutions have helped refine our knowledge of both the continuous and discrete mass loss from the system, and its interactions with more extended material around the star.

  16. Non-thermal X-ray Emission from Supernova Remnants

    E-Print Network [OSTI]

    Jacco Vink

    2004-09-21

    Recent studies of narrow, X-ray synchrotron radiating filaments surrounding young supernova remnants indicate that magnetic fields strengths are relatively high, B ~ 0.1 mG, or even higher, and that diffusion is close to the Bohm limit. I illustrate this using Cas A as an example. Also older remnants such as RCW 86 appear to emit X-ray synchrotron radiation, but the emission is more diffuse, and not always confined to a region close to the shock front. I argue that for RCW 86 the magnetic field is likely to be low (B ~ 17 microGauss), and at the location where the shell emits X-ray synchrotron radiation the shock velocity is much higher than the average shock velocity of ~600 km/s.

  17. Imaging X-ray Thomson Scattering Spectrometer Design and Demonstration

    SciTech Connect (OSTI)

    Gamboa, E.J.; Huntington, C.M.; Trantham, M.R.; Keiter, P.A; Drake, R.P.; Montgomery, David; Benage, John F.; Letzring, Samuel A.

    2012-05-04

    In many laboratory astrophysics experiments, intense laser irradiation creates novel material conditions with large, one-dimensional gradients in the temperature, density, and ionization state. X-ray Thomson scattering is a powerful technique for measuring these plasma parameters. However, the scattered signal has previously been measured with little or no spatial resolution, which limits the ability to diagnose inhomogeneous plasmas. We report on the development of a new imaging x-ray Thomson spectrometer (IXTS) for the Omega laser facility. The diffraction of x-rays from a toroidally-curved crystal creates high-resolution images that are spatially resolved along a one-dimensional profile while spectrally dispersing the radiation. This focusing geometry allows for high brightness while localizing noise sources and improving the linearity of the dispersion. Preliminary results are presented from a scattering experiment that used the IXTS to measure the temperature profile of a shocked carbon foam.

  18. X-ray radiography with highly charged ions

    DOE Patents [OSTI]

    Marrs, Roscoe E. (Livermore, CA)

    2000-01-01

    An extremely small (1-250 micron FWHM) beam of slow highly charged ions deexciting on an x-ray production target generates x-ray monochromatic radiation that is passed through a specimen and detected for imaging. The resolution of the x-ray radiograms is improved and such detection is achieved with relatively low dosages of radiation passing through the specimen. An apparatus containing an electron beam ion trap (and modifications thereof) equipped with a focusing column serves as a source of ions that generate radiation projected onto an image detector. Electronic and other detectors are able to detect an increased amount of radiation per pixel than achieved by previous methods and apparati.

  19. Quiescent X-ray emission from an evolved brown dwarf ?

    E-Print Network [OSTI]

    B. Stelzer

    2004-09-27

    I report on the X-ray detection of Gl569Bab. During a 25ksec Chandra observation the binary brown dwarf is for the first time spatially separated in X-rays from the flare star primary Gl569A. Companionship to Gl569A constrains the age of the brown dwarf pair to ~300-800 Myr. The observation presented here is only the second X-ray detection of an evolved brown dwarf. About half of the observing time is dominated by a large flare on Gl569Bab, the remainder is characterized by weak and non-variable emission just above the detection limit. This emission -- if not related to the afterglow of the flare -- represents the first detection of a quiescent corona on a brown dwarf, representing an important piece in the puzzle of dynamos in the sub-stellar regime.

  20. Application of a PWFA to an X-ray FEL

    E-Print Network [OSTI]

    Israeli, Yasmine; Reiche, Sven; Pedrozzi, Marco; Muggli, Patric

    2016-01-01

    There is a growing demand for X-ray Free-electron lasers (FELs) in various science fields, in particular for those with short pulses, larger photon fluxes and shorter wavelengths. The level of X-ray power and the pulse energy depend on the amount of electron bunch energy. Increasing the latter will increase the power of the radiating X-rays. Using numerical simulations we explore the possibility of using a plasma wakefield accelerator (PWFA) scheme to increase the electron beam energy of an existing FEL facility without significantly increasing the accelerator length. In this paper we use parameters of the SwissFEL beam. The simulations are carried out in 2D cylindrical symmetry using the code OSIRIS. Initial results show an energy gain of ~2 GeV after propagation of 0.5 m in the plasma with a relative energy spread of ~1%.

  1. Data fusion in neutron and X-ray computed tomography

    SciTech Connect (OSTI)

    Schrapp, Michael J.; Goldammer, Matthias; Schulz, Michael; Issani, Siraj; Bhamidipati, Suryanarayana; Böni, Peter

    2014-10-28

    We present a fusion methodology between neutron and X-ray computed tomography (CT). On the one hand, the inspection by X-ray CT of a wide class of multimaterials in non-destructive testing applications suffers from limited information of object features. On the other hand, neutron imaging can provide complementary data in such a way that the combination of both data sets fully characterizes the object. In this contribution, a novel data fusion procedure, called Fusion Regularized Simultaneous Algebraic Reconstruction Technique, is developed where the X-ray reconstruction is modified to fulfill the available data from the imaging with neutrons. The experiments, which were obtained from an aluminum profile containing a steel screw, and attached carbon fiber plates demonstrate that the image quality in CT can be significantly improved when the proposed fusion method is used.

  2. Lensless x-ray imaging in reflection geometry

    SciTech Connect (OSTI)

    Roy, S.; Parks, D.H.; Seu, K.A.; Turner, J.J.; Chao, W.; Anderson, E.H.; Cabrini, S.; Kevan, S.D.; Su, R.

    2011-02-03

    Lensless X-ray imaging techniques such as coherent diffraction imaging and ptychography, and Fourier transform holography can provide time-resolved, diffraction-limited images. Nearly all examples of these techniques have focused on transmission geometry, restricting the samples and reciprocal spaces that can be investigated. We report a lensless X-ray technique developed for imaging in Bragg and small-angle scattering geometries, which may also find application in transmission geometries. We demonstrate this by imaging a nanofabricated pseudorandom binary structure in small-angle reflection geometry. The technique can be used with extended objects, places no restriction on sample size, and requires no additional sample masking. The realization of X-ray lensless imaging in reflection geometry opens up the possibility of single-shot imaging of surfaces in thin films, buried interfaces in magnetic multilayers, organic photovoltaic and field-effect transistor devices, or Bragg planes in a single crystal.

  3. Biological imaging by soft x-ray diffraction microscopy

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Shapiro, D.; Thibault, P.; Beetz, T.; Elser, V.; Howells, M.; Jacobsen, C.; Kirz, J.; Lima, E.; Miao, H.; Neiman, A. M.; et al

    2005-10-25

    We have used the method of x-ray diffraction microscopy to image the complex-valued exit wave of an intact and unstained yeast cell. The images of the freeze-dried cell, obtained by using 750-eV x-rays from different angular orientations, portray several of the cell's major internal components to 30-nm resolution. The good agreement among the independently recovered structures demonstrates the accuracy of the imaging technique. To obtain the best possible reconstructions, we have implemented procedures for handling noisy and incomplete diffraction data, and we propose a method for determining the reconstructed resolution. This work represents a previously uncharacterized application of x-ray diffractionmore »microscopy to a specimen of this complexity and provides confidence in the feasibility of the ultimate goal of imaging biological specimens at 10-nm resolution in three dimensions.« less

  4. The X-ray Telescope of the CAST Experiment

    E-Print Network [OSTI]

    R. Kotthaus; H. Braeuninger; P. Friedrich; R. Hartmann; D. Kang; M. Kuster; G. Lutz; L. Strueder

    2005-11-14

    The CERN Axion Solar Telescope (CAST) searches for solar axions employing a 9 Tesla superconducting dipole magnet equipped with 3 independent detection systems for X-rays from axion-photon conversions inside the 10 m long magnetic field. Results of the first 6 months of data taking in 2003 imply a 95 % CL upper limit on the axion-photon coupling constant of 1.16x10(-10) GeV(-1) for axion masses CAST is a X-ray telescope consisting of a Wolter I type mirror system and a fully depleted pn-CCD as focal plane detector. Exploiting the full potential of background suppression by focussing X-rays emerging from the magnet bore, the axion sensitivity obtained with telescope data taken in 2004, for the first time in a controlled laboratory experiment, will supersede axion constraints derived from stellar energy loss arguments.

  5. X-ray vs. water maser emission in AGN

    E-Print Network [OSTI]

    Castangia, P; Kadler, M; Henkel, C; Greenhill, L; Tueller, J

    2009-01-01

    Correlations between X-ray and water maser emission in AGN have been recently reported. However, the lack of systematic studies affects the confidence level of these results. In the following, we introduce a project aimed at studying all the water maser sources believed to be associated with AGN activity through X-ray data obtained with the XRT and BAT instruments on-board the Swift satellite. Preliminary results of this work indicate a promising rate of XRT detections allowing us to refine follow-up observing strategies focused on investigating the nuclei of individual galaxies and deriving, on statistical basis, the main characteristics of water maser hosts. In addition, a cross-correlation between our sample and the BAT 22-months all-sky survey provides an exceptionally high detection rate at hard X-ray energies when compared to other AGN-related catalogs.

  6. Movable anode x-ray source with enhanced anode cooling

    DOE Patents [OSTI]

    Bird, C.R.; Rockett, P.D.

    1987-08-04

    An x-ray source is disclosed having a cathode and a disc-shaped anode with a peripheral surface at constant radius from the anode axis opposed to the cathode. The anode has stub axle sections rotatably carried in heat conducting bearing plates which are mounted by thermoelectric coolers to bellows which normally bias the bearing plates to a retracted position spaced from opposing anode side faces. The bellows cooperate with the x-ray source mounting structure for forming closed passages for heat transport fluid. Flow of such fluid under pressure expands the bellows and brings the bearing plates into heat conducting contact with the anode side faces. A worm gear is mounted on a shaft and engages serrations in the anode periphery for rotating the anode when flow of coolant is terminated between x-ray emission events. 5 figs.

  7. Movable anode x-ray source with enhanced anode cooling

    DOE Patents [OSTI]

    Bird, Charles R. (Ypsilanti, MI); Rockett, Paul D. (Ann Arbor, MI)

    1987-01-01

    An x-ray source having a cathode and a disc-shaped anode with a peripheral surface at constant radius from the anode axis opposed to the cathode. The anode has stub axle sections rotatably carried in heat conducting bearing plates which are mounted by thermoelectric coolers to bellows which normally bias the bearing plates to a retracted position spaced from opposing anode side faces. The bellows cooperate with the x-ray source mounting structure for forming closed passages for heat transport fluid. Flow of such fluid under pressure expands the bellows and brings the bearing plates into heat conducting contact with the anode side faces. A worm gear is mounted on a shaft and engages serrations in the anode periphery for rotating the anode when flow of coolant is terminated between x-ray emission events.

  8. Experimental investigation of the parameter space for optical-field-ionization cluster-jet x-ray lasers

    E-Print Network [OSTI]

    , National Chung Cheng University, Chia-Yi 621, Taiwan 3 Department of Physics, National Taiwan University presented. By seeding an OFI x-ray laser amplifier with a pulse produced from high harmonic generation of the seed pulse 13 . In view of the versatility of gas jets, our group demonstrated nearly saturated x

  9. High efficiency of soft X-ray radiation reprocessing in supersoft X-ray sources due to multiple scattering

    E-Print Network [OSTI]

    V. Suleimanov; F. Meyer; E. Meyer-Hofmeister

    2003-02-19

    Detailed analysis of the lightcurve of CAL 87 clearly has shown that the high optical luminosity comes from the accretion disc rim and can only be explained by a severe thickening of the disc rim near the location where the accretion stream impinges. This area is irradiated by the X-rays where it faces the white dwarf. Only if the reprocessing rate of X-rays to optical light is high a luminosity as high as observed can be understood. But a recent detailed study of the soft X-ray radiation reprocessing in supersoft X-ray sources has shown that the efficiency is not high enough. We here propose a solution for this problem. As already discussed in the earlier lightcurve analysis the impact of the accretion stream at the outer disc rim produces a ``spray'', consisting of a large number of individual gas blobs imbedded in a surrounding corona. For the high mass flow rate this constitutes an optically thick vertically extended screen at the rim of the accretion disc. We analyse the optical properties of this irradiated spray and find that the multiple scattering between these gas blobs leads to an effective reprocessing of soft X-rays to optical light as required by the observations.

  10. High-resolution X-ray spectroscopy of Theta Car

    E-Print Network [OSTI]

    Yael Naze; Gregor Rauw

    2008-08-25

    Context : The peculiar hot star Theta Car in the open cluster IC2602 is a blue straggler as well as a single-line binary of short period (2.2d). Aims : Its high-energy properties are not well known, though X-rays can provide useful constraints on the energetic processes at work in binaries as well as in peculiar, single objects. Methods : We present the analysis of a 50ks exposure taken with the XMM-Newton observatory. It provides medium as well as high-resolution spectroscopy. Results : Our high-resolution spectroscopy analysis reveals a very soft spectrum with multiple temperature components (1--6MK) and an X-ray flux slightly below the `canonical' value (log[L_X(0.1-10.)/L_{BOL}] ~ -7). The X-ray lines appear surprisingly narrow and unshifted, reminiscent of those of beta Cru and tau Sco. Their relative intensities confirm the anomalous abundances detected in the optical domain (C strongly depleted, N strongly enriched, O slightly depleted). In addition, the X-ray data favor a slight depletion in neon and iron, but they are less conclusive for the magnesium abundance (solar-like?). While no significant changes occur during the XMM-Newton observation, variability in the X-ray domain is detected on the long-term range. The formation radius of the X-ray emission is loosely constrained to <5 R_sol, which allows for a range of models (wind-shock, corona, magnetic confinement,...) though not all of them can be reconciled with the softness of the spectrum and the narrowness of the lines.

  11. X Ray Precursors in SGRs: Precessing Gamma Jet Tails

    E-Print Network [OSTI]

    Daniele Fargion

    2001-05-18

    Weak isolated X-ray precursor events before the main Gamma Ray Burst, GRB, and also rare Soft Gamma Repeaters, SGR, events are in complete disagreement with any Fireball, or Magnetar, one-shoot explosive scenarios. Fireball model in last two years has been deeply modified into a fountain beamed Jet exploding and interacting on external shells to explain GRB fine time structure. On the contrary earlier we proposed a unified scenario for both GRBs-SGRs where a precessing Gamma Jet (of different intensity) and its geometrical beaming is the source of both GRB and SGRs wide morphology. GRBs are peaked SNs Jet spinning and precessing observed along the thin Jet axis. Their mysterious weak X precursors bursts, corresponding to non-negligible energy powers, up to million Supernova ones for GRB, are gamma Jet tails beamed off-axis, observed at X-Ray tails. They are rare, about (3-6)% of all GRBs, but not unique at all. Comparable brief X-ray precursor flashes occurred in rarest and most detailed SGRs events as the 27 and the 29 August 1998 event from SGR 1900+14. The same source has been in very power-full activity on recent 18 April 2001 once again preceded by X-Ray precursors. These events are inconsistent with any Fireball or Magnetar-Mini-Fireball models. We interpret them naturally as earlier marginal blazing of outlying X conical precessing Jet, an off-axis tails surrounding a narrower gamma precessing Jet. Only when the light-house Jet is in on-axis blazing mode toward the Earth we observe the harder power-full SGR event. We predict such a rich X-Ray precursor signals (more numerous then gamma ones) during Soft Gamma Repeater peak activities; they should be abundant and within detection threshold by a permanent monitoring SGRs by Beppo-Sax WFC or Chandra X ray satellites while at peak activity.

  12. Concave Accretion Discs and X-ray Reprocessing

    E-Print Network [OSTI]

    Eric G. Blackman

    1999-03-16

    Spectra of Seyfert Is are commonly modelled as emission from an X-ray illuminated flat accretion disc orbiting a central black hole. This provides both a reprocessed and direct component of the X-ray emission as required by observations of individual objects and possibly a fraction of the cosmological X-ray background. There is some observational motivation to at least consider the role that an effectively concave disc surface might play: (1) a reprocessed fraction $\\gsim 1/2$ in some Seyferts and possibly in the X-ray background, and (2) the commonality of a sharp iron line peak for Seyferts at 6.4KeV despite a dependence of peak location on inclination angle for flat disc models. Here it is shown that a concave disc may not only provide a larger total fraction of reprocessed photons, but can also reprocess a much larger fraction of photons in its outer regions when compared to a flat disc. This reduces the sensitivity of the 6.4KeV peak location to the inner disc inclination angle because the outer regions are less affected by Doppler and gravitational effects. If the X-ray source is isotropic, the reprocessed fraction is directly determined by the concavity. If the X-ray source is anisotropic, the location of iron line peak can still be determined by concavity but the total reflected fraction need not be as large as for the isotropic emitter case. The geometric calculations herein are applicable to general accretion disc systems illuminated from the center.

  13. Serial femtosecond X-ray diffraction of enveloped virus microcrystals

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Lawrence, Robert M.; Conrad, Chelsie E.; Zatsepin, Nadia A.; Grant, Thomas D.; Liu, Haiguang; James, Daniel; Nelson, Garrett; Subramanian, Ganesh; Aquila, Andrew; Hunter, Mark S.; et al

    2015-08-20

    Serial femtosecond crystallography (SFX) using X-ray free-electron lasers has produced high-resolution, room temperature, time-resolved protein structures. We report preliminary SFX of Sindbis virus, an enveloped icosahedral RNA virus with ~700 Å diameter. Microcrystals delivered in viscous agarose medium diffracted to ~40 Å resolution. Small-angle diffuse X-ray scattering overlaid Bragg peaks and analysis suggests this results from molecular transforms of individual particles. Viral proteins undergo structural changes during entry and infection, which could, in principle, be studied with SFX. This is a pertinent step toward determining room temperature structures from virus microcrystals that may enable time-resolved studies of enveloped viruses.

  14. Cooled window for X-rays or charged particles

    DOE Patents [OSTI]

    Logan, C.M.

    1996-04-16

    A window is disclosed that provides good structural integrity and a very high capacity for removal of the heat deposited by x-rays, electrons, or ions, with minimum attenuation of the desired beam. The window is cooled by providing microchannels therein through which a coolant is pumped. For example, the window may be made of silicon with etched microchannels therein and covered by a silicon member. A window made of silicon with a total thickness of 520 {micro}m transmits 96% of the x-rays at an energy of 60 keV, and the transmission is higher than 90% for higher energy photons. 1 fig.

  15. Cooled window for X-rays or charged particles

    DOE Patents [OSTI]

    Logan, Clinton M. (Pleasanton, CA)

    1996-01-01

    A window that provides good structural integrity and a very high capacity for removal of the heat deposited by x-rays, electrons, or ions, with minimum attenuation of the desired beam. The window is cooled by providing microchannels therein through which a coolant is pumped. For example, the window may be made of silicon with etched microchannels therein and covered by a silicon member. A window made of silicon with a total thickness of 520 .mu.m transmits 96% of the x-rays at an energy of 60 keV, and the transmission is higher than 90% for higher energy photons.

  16. A 0535+26: an X-ray/Optical Tour

    E-Print Network [OSTI]

    Camero-Arranz, A; Wilson-Hodge, C A; Jenke, P; Coe, M J; Steele, I; Caballero, I; Gutierrez-Soto, J; Kretschmar, P; Suso, J; McBride, V A; Rodriguez, J

    2011-01-01

    We compiled X-ray and Optical observations of the accreting X-ray binary system A 0535+262 since its discovery in 1975, that will allow us to shed light on the unpredictable behavior of this binary system. We present the data in terms of the Be-disk interaction with the neutron star companion. In addition, we show recent results from the continuous monitoring of this source by the Gamma-ray Burst Monitor(GBM), on board the Fermi observatory, since its launch in 2008 June 11.

  17. Bragg x-ray survey spectrometer for ITER

    SciTech Connect (OSTI)

    Varshney, S. K.; Jakhar, S. [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, Gujarat 382428 (India); Barnsley, R. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); O'Mullane, M. G. [Department of Physics, University of Strathclyde, Glasgow G4 0NG (United Kingdom)

    2012-10-15

    Several potential impurity ions in the ITER plasmas will lead to loss of confined energy through line and continuum emission. For real time monitoring of impurities, a seven channel Bragg x-ray spectrometer (XRCS survey) is considered. This paper presents design and analysis of the spectrometer, including x-ray tracing by the Shadow-XOP code, sensitivity calculations for reference H-mode plasma and neutronics assessment. The XRCS survey performance analysis shows that the ITER measurement requirements of impurity monitoring in 10 ms integration time at the minimum levels for low-Z to high-Z impurity ions can largely be met.

  18. High resolution collimator system for X-ray detector

    DOE Patents [OSTI]

    Eberhard, Jeffrey W. (Schenectady, NY); Cain, Dallas E. (Scotia, NY)

    1987-01-01

    High resolution in an X-ray computerized tomography (CT) inspection system is achieved by using a collimator/detector combination to limit the beam width of the X-ray beam incident on a detector element to the desired resolution width. In a detector such as a high pressure Xenon detector array, a narrow tapered collimator is provided above a wide detector element. The collimator slits have any desired width, as small as a few mils at the top, the slit width is easily controlled, and they are fabricated on standard machines. The slit length determines the slice thickness of the CT image.

  19. The First Angstrom X-Ray Free-Electron Laser

    SciTech Connect (OSTI)

    Galayda, John; /SLAC

    2012-08-24

    The Linac Coherent Light Source produced its first x-ray laser beam on 10 April 2009. Today it is routinely producing x-ray pulses with energy >2 mJ across the operating range from 820-8,200 eV. The facility has begun operating for atomic/molecular/optical science experiments. Performance of the facility in its first user run (1 October - 21 December) and current machine development activities will be presented. Early results from the preparations for the start of the second user run is also reported.

  20. X-Ray Diffraction Microscopy of Magnetic Structures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWind Power >X-RayX-Ray

  1. X-Ray Microscopy Capabilities | Argonne National Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWindX-Ray Imaging of theX-Ray

  2. X-Ray Microscopy and Imaging: Science and Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWindX-Ray ImagingIn the X-ray

  3. An SZ/X-ray galaxy cluster model and the X-ray follow-up of the Planck clusters

    E-Print Network [OSTI]

    A. Chamballu; J. G. Bartlett; J. -B. Melin; M. Arnaud

    2008-05-28

    Sunyaev-Zel'dovich (SZ) cluster surveys will become an important cosmological tool over next few years, and it will be essential to relate these new surveys to cluster surveys in other wavebands. We present an empirical model of cluster SZ and X-ray observables constructed to address this question and to motivate, dimension and guide X-ray follow-up of SZ surveys. As an example application of the model, we discuss potential XMM-Newton follow-up of Planck clusters.

  4. A mirror for lab-based quasi-monochromatic parallel x-rays

    SciTech Connect (OSTI)

    Nguyen, Thanhhai; Lu, Xun; Lee, Chang Jun; Jeon, Insu; Jung, Jin-Ho; Jin, Gye-Hwan; Kim, Sung Youb

    2014-09-15

    A multilayered parabolic mirror with six W/Al bilayers was designed and fabricated to generate monochromatic parallel x-rays using a lab-based x-ray source. Using this mirror, curved bright bands were obtained in x-ray images as reflected x-rays. The parallelism of the reflected x-rays was investigated using the shape of the bands. The intensity and monochromatic characteristics of the reflected x-rays were evaluated through measurements of the x-ray spectra in the band. High intensity, nearly monochromatic, and parallel x-rays, which can be used for high resolution x-ray microscopes and local radiation therapy systems, were obtained.

  5. Enhanced Electron Efficiency in an X-ray Diode

    SciTech Connect (OSTI)

    K. Sun, L. MacNeil

    2010-05-20

    The goal for this research is to optimize the XRD structure and usage configurations and increase the efficiency of the XRD. This research was successful in optimizing the XRD structure and usage configurations, thus creating a high efficiency XRD. Best efficiency occurs when there is an angle between the photocathode and incident X-rays.

  6. DEDUCING ELECTRON PROPERTIES FROM HARD X-RAY OBSERVATIONS

    E-Print Network [OSTI]

    Piana, Michele

    , University of New Hampshire, Durham, NH 03824, U.S.A. 9 Dipartimento di Informatica, Universit`a di Verona-ray polarization measurements have imposed significant new constraints on the degree of anisotropy distribution 42 5.5 X-ray polarization and electr

  7. Lensless imaging of nanoporous glass with soft X-rays

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Turner, Joshua J.; Nelson, Johanna; Huang, Xiaojing; Steinbrener, Jan; Jacobsen, Chris

    2013-06-01

    Coherent soft X-ray diffraction has been used to image nanoporous glass structure in two dimensions using different methods. The merit of the reconstructions was judged using a new method of Fourier phase correlation with a final, refined image. The porous structure was found to have a much larger average size then previously believed.

  8. STRUCTURAL VIROLOGY X-ray crystal structures of native

    E-Print Network [OSTI]

    Napp, Nils

    STRUCTURAL VIROLOGY X-ray crystal structures of native HIV-1 capsid protein reveal conformational) hexamers that shield the viral genome and proteins have been elusive. We report crystal structures-binding site. Inherent structural plasticity, hydration layer rearrangement, and effector binding affect capsid

  9. X-ray Emission from Thunderstorms and Lightning

    ScienceCinema (OSTI)

    Dwyer, Joseph [Florida Institute of Technology, Melbourne, Florida, United States

    2010-01-08

    How lightning is initiated in the relatively low electric fields inside thunderclouds and how it can then propagate for tens of kilometers through virgin air are two of the great unsolved problems in the atmospheric sciences.  Until very recently it was believed that lightning was entirely a conventional discharge, involving only low-energy (a few eV) electrons.  This picture changed completely a few years ago with the discovery of intense x-ray emission from both natural cloud-to-ground lightning and rocket-triggered lightning.  This energetic emission cannot be produced by a conventional discharge, and so the presence of x-rays strongly implies that runaway breakdown plays a role in lightning processes.  During runaway breakdown, electrons are accelerated through air to nearly the speed of light by strong electric fields.  These runaway electrons then emit bremsstrahlung x-rays and gamma-rays during collisions with air.  Indeed, the x-ray and gamma-ray emission produced by runaway breakdown near the tops of thunderstorms is bright enough to be seen from outer space, 600 km away.  As a result, the physics used for decades to describe thunderstorm electrification and lightning discharges is incomplete and needs to be revisited. 

  10. Generating coherent broadband continuum soft-x-ray radiation by

    E-Print Network [OSTI]

    Neumark, Daniel M.

    Generating coherent broadband continuum soft-x-ray radiation by attosecond ionization gating Thomas as the driver for high-harmonic generation that has a cosine-like electric field stabilized with respect the generation of broadband and tunable attosecond pulses. Instead of fixing the carrier-envelope phase

  11. Vanadium-pumped titanium x-ray laser

    DOE Patents [OSTI]

    Nilsen, Joseph (Livermore, CA)

    1992-01-01

    A resonantly photo-pumped x-ray laser (10) is formed of a vanadium (12) and titanium (14) foil combination (16) that is driven by two beams (18, 20) of intense line focused (22, 24) optical laser radiation. Ground state neon-like titanium ions (34) are resonantly photo-pumped by line emission from fluorine-like vanadium ions (32).

  12. Vanadium-pumped titanium x-ray laser

    DOE Patents [OSTI]

    Nilsen, J.

    1992-05-26

    A resonantly photo-pumped x-ray laser is formed of a vanadium and titanium foil combination that is driven by two beams of intense line focused optical laser radiation. Ground state neon-like titanium ions are resonantly photo-pumped by line emission from fluorine-like vanadium ions. 4 figs.

  13. Soft x-ray diagnostics for pulsed power machines

    SciTech Connect (OSTI)

    Idzorek, G.C.; Coulter, W.L.; Walsh, P.J.; Montoya, R.R.

    1995-08-01

    A variety of soft x-ray diagnostics are being fielded on the Los Alamos National Laboratory Pegasus and Procyon pulsed power systems and also being fielded on joint US/Russian magnetized target fusion experiments known as MAGO (Magnitoye Obzhatiye). The authors have designed a low-cost modular photoemissive detector designated the XRD-96 that uses commercial 1100 series aluminum for the photocathode. In addition to photocathode detectors a number of designs using solid state silicon photodiodes have been designed and fielded. They also present a soft x-ray time-integrated pinhole camera system that uses standard type TMAX-400 photographic film that obviates the need for expensive and no longer produced zero-overcoat soft x-ray emulsion film. In a typical experiment the desired spectral energy cuts, signal intensity levels, and desired field of view will determine diagnostic geometry and x-ray filters selected. The authors have developed several computer codes to assist in the diagnostic design process and data deconvolution. Examples of the diagnostic design process and data analysis for a typical pulsed power experiment are presented.

  14. X-ray Spectral Properties of the BAT AGN Sample

    E-Print Network [OSTI]

    L. M. Winter; R. Mushotzky; C. S. Reynolds; J. Tueller

    2008-08-04

    The 9-month Swift Burst Alert Telescope (BAT) catalog provides the first unbiased (log N_H = 0.03) AGN. In this paper, we present the collected X-ray properties (0.3 - 12keV) for the 153 AGN detected. In addition, we examine the X-ray properties for a complete sample of non-beamed sources, above the Galactic plane. Of these, 45% are best fit by simple power law models while 55% require the more complex partial covering model. One of our goals was to determine the fraction of "hidden" AGN, which we define as sources with scattering fractions Marshall et al. 1980). From the log N-log S relationship, we show that we are complete to log S < -11 in the 2-10 keV band. Both the collected X-ray properties of our uniform sample and the log N-log S relationship will now provide valuable input to X-ray background models for z ~ 0. (abridged)

  15. Compact X-ray Light Source Workshop Report

    SciTech Connect (OSTI)

    Thevuthasan, Suntharampillai; Evans, James E.; Terminello, Louis J.; Koppenaal, David W.; Manke, Kristin L.; Plata, Charity

    2012-12-01

    This report, produced jointly by EMSL and FCSD, is the result of a workshop held in September 2011 that examined the utility of a compact x-ray light source (CXLS) in addressing many scientific challenges critical to advancing energy science and technology.

  16. The X-ray emission of the gamma Cassiopiae stars

    E-Print Network [OSTI]

    Smith, Myron A; Motch, C

    2015-01-01

    Long considered as the "odd man out" among X-ray emitting Be stars, \\gamma Cas (B0.5e\\,IV) is now recognized as the prototype of a class of stars that emit hard thermal X-rays. Our classification differs from the historical use of the term "gamma Cas stars" defined from optical properties alone. The luminosity output of this class contributes significantly to the hard X-ray production of massive stars in the Galaxy. The gamma Cas stars have light curves showing variability on a few broadly-defined timescales and spectra indicative of an optically thin plasma consisting of one or more hot thermal components. By now 9--13 Galactic \\approx B0-1.5e main sequence stars are judged to be members or candidate members of the \\gc\\ class. Conservative criteria for this designation are for a \\approxB0-1.5e III-V star to have an X-ray luminosity of 10^{32}--10^{33} ergs s^{-1}, a hot thermal spectrum containing the short wavelength Ly \\alpha FeXXV and FeXXVI lines and the fluorescence FeK feature all in emission. If therm...

  17. Operational properties of fluctuation X-ray scattering data

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Malmerberg, Erik; Kerfeld, Cheryl A.; Zwart, Petrus H.

    2015-03-20

    X-ray scattering images collected on timescales shorter than rotation diffusion times using a (partially) coherent beam result in a significant increase in information content in the scattered data. These measurements, named fluctuation X-ray scattering (FXS), are typically performed on an X-ray free-electron laser (XFEL) and can provide fundamental insights into the structure of biological molecules, engineered nanoparticles or energy-related mesoscopic materials beyond what can be obtained with standard X-ray scattering techniques. In order to understand, use and validate experimental FXS data, the availability of basic data characteristics and operational properties is essential, but has been absent up to this point.more »In this communication, an intuitive view of the nature of FXS data and their properties is provided, the effect of FXS data on the derived structural models is highlighted, and generalizations of the Guinier and Porod laws that can ultimately be used to plan experiments and assess the quality of experimental data are presented.« less

  18. X-rays at Solid-Liquid Surfaces

    SciTech Connect (OSTI)

    Dosch, Helmut (Max Planck Institute for Metals Research) [Max Planck Institute for Metals Research

    2007-05-02

    Solid-liquid interfaces play an important role in many areas of current and future technologies, and in our biosphere. They play a key role in the development of nanofluidics and nanotribology, which sensitively depend on our knowledge of the microscopic structures and phenomena at the solid-liquid interface. The detailed understanding of how a fluid meets a wall is also a theoretical challenge. In particular, the phenomena at repulsive walls are of interest, since they affect many different phenomena, such as water-repellent surfaces or the role of the hydrophobic interaction in protein folding. Recent x-ray reflectivity studies of various solid-liquid interfaces have disclosed rather intriguiing phenomena, which will be discussed in this lecture: premelting of ice in contact with silica; liquid Pb in contact with Si; water in contact with hydrophobic surfaces. These experiments, carried out with high-energy x-ray microbeams, reveal detailed insight into the liquid density profile closest to the wall. A detailed insight into atomistic phenomena at solid-liquid interfaces is also a prerequisite in the microscopic control of electrochemical reactions at interfaces. Recent x-ray studies show the enormous future potential of such non-destructive analytical tools for the in situ observation of (electro-)chemical surface reactions. This lecture will review recent x-ray experiments on solid-liquid interfaces.

  19. X-ray Emission from the Winds of Massive Stars

    E-Print Network [OSTI]

    Cohen, David

    X-ray Emission from the Winds of Massive Stars David Cohen Department of Physics & Astronomy-driven stellar winds are a characteristic of massive stars NGC 6888 Crescent Nebula - Tony Hallas #12;NGC 6888 Crescent Nebula - Tony Hallas O star - source of wind bubble: ~1 arc second instrumental resolution; star

  20. X-ray characterization of solid small molecule organic materials

    SciTech Connect (OSTI)

    Billinge, Simon; Shankland, Kenneth; Shankland, Norman; Florence, Alastair

    2014-06-10

    The present invention provides, inter alia, methods of characterizing a small molecule organic material, e.g., a drug or a drug product. This method includes subjecting the solid small molecule organic material to x-ray total scattering analysis at a short wavelength, collecting data generated thereby, and mathematically transforming the data to provide a refined set of data.

  1. USE OF DIAGNOSTIC X-RAY FOR DETERMINING

    E-Print Network [OSTI]

    in such studies because of the great amount of tipie and effort required in dissection of vertebral columns of individual fish, but provide a permanent record of the vertebral column for future referenceUSE OF DIAGNOSTIC X-RAY FOR DETERMINING VERTEBRAL NUMBERS OF FISH Marine Biological Labo

  2. Crystal defect studies using x-ray diffuse scattering

    SciTech Connect (OSTI)

    Larson, B.C.

    1980-01-01

    Microscopic lattice defects such as point (single atom) defects, dislocation loops, and solute precipitates are characterized by local electronic density changes at the defect sites and by distortions of the lattice structure surrounding the defects. The effect of these interruptions of the crystal lattice on the scattering of x-rays is considered in this paper, and examples are presented of the use of the diffuse scattering to study the defects. X-ray studies of self-interstitials in electron irradiated aluminum and copper are discussed in terms of the identification of the interstitial configuration. Methods for detecting the onset of point defect aggregation into dislocation loops are considered and new techniques for the determination of separate size distributions for vacancy loops and interstitial loops are presented. Direct comparisons of dislocation loop measurements by x-rays with existing electron microscopy studies of dislocation loops indicate agreement for larger size loops, but x-ray measurements report higher concentrations in the smaller loop range. Methods for distinguishing between loops and three-dimensional precipitates are discussed and possibilities for detailed studies considered. A comparison of dislocation loop size distributions obtained from integral diffuse scattering measurements with those from TEM show a discrepancy in the smaller sizes similar to that described above.

  3. High resolution, multiple-energy linear sweep detector for x-ray imaging

    DOE Patents [OSTI]

    Perez-Mendez, V.; Goodman, C.A.

    1996-08-20

    Apparatus is disclosed for generating plural electrical signals in a single scan in response to incident X-rays received from an object. Each electrical signal represents an image of the object at a different range of energies of the incident X-rays. The apparatus comprises a first X-ray detector, a second X-ray detector stacked upstream of the first X-ray detector, and an X-ray absorber stacked upstream of the first X-ray detector. The X-ray absorber provides an energy-dependent absorption of the incident X-rays before they are incident at the first X-ray detector, but provides no absorption of the incident X-rays before they are incident at the second X-ray detector. The first X-ray detector includes a linear array of first pixels, each of which produces an electrical output in response to the incident X-rays in a first range of energies. The first X-ray detector also includes a circuit that generates a first electrical signal in response to the electrical output of each of the first pixels. The second X-ray detector includes a linear array of second pixels, each of which produces an electrical output in response to the incident X-rays in a second range of energies, broader than the first range of energies. The second X-ray detector also includes a circuit that generates a second electrical signal in response to the electrical output of each of the second pixels. 12 figs.

  4. High resolution, multiple-energy linear sweep detector for x-ray imaging

    DOE Patents [OSTI]

    Perez-Mendez, Victor (Berkeley, CA); Goodman, Claude A. (Kensington, CA)

    1996-01-01

    Apparatus for generating plural electrical signals in a single scan in response to incident X-rays received from an object. Each electrical signal represents an image of the object at a different range of energies of the incident X-rays. The apparatus comprises a first X-ray detector, a second X-ray detector stacked upstream of the first X-ray detector, and an X-ray absorber stacked upstream of the first X-ray detector. The X-ray absorber provides an energy-dependent absorption of the incident X-rays before they are incident at the first X-ray detector, but provides no absorption of the incident X-rays before they are incident at the second X-ray detector. The first X-ray detector includes a linear array of first pixels, each of which produces an electrical output in response to the incident X-rays in a first range of energies. The first X-ray detector also includes a circuit that generates a first electrical signal in response to the electrical output of each of the first pixels. The second X-ray detector includes a linear array of second pixels, each of which produces an electrical output in response to the incident X-rays in a second range of energies, broader than the first range of energies. The second X-ray detector also includes a circuit that generates a second electrical signal in response to the electrical output of each of the second pixels.

  5. Soft X-ray spectral variability of AM Herculis

    E-Print Network [OSTI]

    K. Beuermann; E. El Kholy; K. Reinsch

    2008-02-19

    Polars (AM Herculis binaries) are a prominent class of bright soft X-ray sources, many of which were discovered with ROSAT. We present a homogenous analysis of all the pointed ROSAT PSPC observations of polars subdivided into two papers that discuss the prototype polar AM Her in detail and summarize the class properties of all other polars. We derive the high-state soft X-ray flux and short-term spectral variability of AM Her using a new detector response matrix and a confirmed flux calibration of the ROSAT PSPC below 0.28 keV. The best-fit mean single-blackbody temperature and integrated bright-phase energy flux of AM Her in its April 1991 high state are 27.2 +/- 1.0 eV and (2.6 +/- 0.6) x 10^-9 erg cm^-2s^-1, respectively. The total blackbody flux of a multi-temperature model that fits both the soft X-ray and the fluctuating far-ultraviolet components is Fbb = (4.5 +/- 1.5) x 10^-9 erg cm^-2s^-1. The total accretion luminosity at a distance of 80 pc, Lbb = (2.1 +/- 0.7) x 10^33 erg s-1, implies an accretion rate of Mdot = (2.4 +/- 0.8) x 10^-10 Msun yr^-1 for an 0.78 Msun white dwarf. The soft X-ray flux displays significant variability on time scales down to 200 ms. Correlated spectral and count-rate variations are seen in flares on time scales down to 1 s, demonstrating the heating and cooling associated with individual accretion events. Our spectral and temporal analysis provides direct evidence for the blobby accretion model and suggests a connection between the soft X-ray and the fluctuating far-ultraviolet components.

  6. X-ray ablation measurements and modeling for ICF applications

    SciTech Connect (OSTI)

    Anderson, A.T.

    1996-09-01

    X-ray ablation of material from the first wall and other components of an ICF (Inertial Confinement Fusion) chamber is a major threat to the laser final optics. Material condensing on these optics after a shot may cause damage with subsequent laser shots. To ensure the successful operation of the ICF facility, removal rates must be predicted accurately. The goal for this dissertation is to develop an experimentally validated x-ray response model, with particular application to the National Ignition Facility (NIF). Accurate knowledge of the x-ray and debris emissions from ICF targets is a critical first step in the process of predicting the performance of the target chamber system. A number of 1-D numerical simulations of NIF targets have been run to characterize target output in terms of energy, angular distribution, spectrum, and pulse shape. Scaling of output characteristics with variations of both target yield and hohlraum wall thickness are also described. Experiments have been conducted at the Nova laser on the effects of relevant x-ray fluences on various materials. The response was diagnosed using post-shot examinations of the surfaces with scanning electron microscope and atomic force microscope instruments. Judgments were made about the dominant removal mechanisms for each material. Measurements of removal depths were made to provide data for the modeling. The finite difference ablation code developed here (ABLATOR) combines the thermomechanical response of materials to x-rays with models of various removal mechanisms. The former aspect refers to energy deposition in such small characteristic depths ({approx} micron) that thermal conduction and hydrodynamic motion are significant effects on the nanosecond time scale. The material removal models use the resulting time histories of temperature and pressure-profiles, along with ancillary local conditions, to predict rates of surface vaporization and the onset of conditions that would lead to spallation.

  7. Polarization periodicity in the B1 columnar phase determined by resonant x-ray scattering

    SciTech Connect (OSTI)

    Folcia, C.L.; Pindak, R.; Ortega, J.; Etxebarria, J.; Pan, L.; Wang, S.; Huang, C.C.; Ponsinet, V.; Barois, P. and Gimeno, N.

    2011-07-14

    We report structural results that evidence the polarization distribution of the blocks in the columnar phase of an achiral bent-core liquid crystal. The study was performed using resonant x-ray diffraction at the sulfur K edge on oriented samples aligned on substrates. The extra periodicity is revealed through the violation of the systematic extinction rule of the structural symmetry group along the experimentally accessible diffraction direction. Further data obtained from the polarization analysis of a resonant reflection give information concerning the transition mechanism between B{sub 1} and B{sub 2} phases.

  8. Polarization Periodicity in the B(1) Columnar Phase Determined by Resonant X-ray Scattering

    SciTech Connect (OSTI)

    C Folcia; J Ortega; J Etxebarria; L Pan; S Wang; C Huang; V Ponsinet; P Barois; R Pindak; N Gimeno

    2011-12-31

    We report structural results that evidence the polarization distribution of the blocks in the columnar phase of an achiral bent-core liquid crystal. The study was performed using resonant x-ray diffraction at the sulfur K edge on oriented samples aligned on substrates. The extra periodicity is revealed through the violation of the systematic extinction rule of the structural symmetry group along the experimentally accessible diffraction direction. Further data obtained from the polarization analysis of a resonant reflection give information concerning the transition mechanism between B{sub 1} and B{sub 2} phases.

  9. Understanding X-ray reflection as a probe of accreting black holes

    E-Print Network [OSTI]

    Wilkins, Daniel Richard

    2013-07-09

    ’ telescope and the rest of the X-ray group (past and present) for their help and, of course, friendship — Julie, Jack, Dom, Abdu, Chia-Ying, to name but a few. I wish also to thank Carolin Crawford for helping hone my passion for public outreach... particles surrounding the central black hole through the process of Comptonisation. Soft, thermal seed photons originating from the accretion disc are inverse-Compton scattered to higher energies multiple times by energetic electrons (whose energy follows a...

  10. An Eulerian CFD model and X-ray radiography for coupled nozzle...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    An Eulerian CFD model and X-ray radiography for coupled nozzle flow and spray in internal combustion engines Title An Eulerian CFD model and X-ray radiography for coupled nozzle...

  11. LINE BROADENING EFFECTS IN X-RAY DIFFRACTION ANALYSIS OF AIR PARTICULATES

    E-Print Network [OSTI]

    O'Connor, B.H.

    2012-01-01

    X-RAY POWDER DIFFRACTION ANALYSIS OF AIR PARTICULATES B. H.Ray Powder Diffraction Analysis Of Air Particulates* B.H. 0X-Ray Powder Diffraction Analysis of Air Particulates* B.H.

  12. Advanced Research in Diesel Fuel Sprays Using X-rays from the...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Research in Diesel Fuel Sprays Using X-rays from the Advanced Photon Source Advanced Research in Diesel Fuel Sprays Using X-rays from the Advanced Photon Source 2003 DEER...

  13. Lensless Imaging of Whole Biological Cells with Soft X-Rays

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lensless Imaging of Whole Biological Cells with Soft X-Rays Print A team of scientists has used x-ray diffraction microscopy at ALS Beamline 9.0.1 to make images of whole yeast...

  14. Bright x-ray sources from laser irradiation of foams with high...

    Office of Scientific and Technical Information (OSTI)

    Bright x-ray sources from laser irradiation of foams with high concentration of Ti Citation Details In-Document Search Title: Bright x-ray sources from laser irradiation of foams...

  15. Nonlinear increase of X-ray intensities from thin foils irradiated...

    Office of Scientific and Technical Information (OSTI)

    increase of X-ray intensities from thin foils irradiated with a 200 TW femtosecond laser Citation Details In-Document Search Title: Nonlinear increase of X-ray intensities...

  16. PROMPT X-RAY AND OPTICAL EXCESS EMISSION DUE TO HADRONIC CASCADES...

    Office of Scientific and Technical Information (OSTI)

    PROMPT X-RAY AND OPTICAL EXCESS EMISSION DUE TO HADRONIC CASCADES IN GAMMA-RAY BURSTS Citation Details In-Document Search Title: PROMPT X-RAY AND OPTICAL EXCESS EMISSION DUE TO...

  17. Ion implantation for figure correction of high-resolution x-ray telescope mirrors

    E-Print Network [OSTI]

    Chalifoux, Brandon D

    2014-01-01

    Fabricating mirrors for future high-resolution, large-aperture x-ray telescopes continues to challenge the x-ray astronomy instrumentation community. Building a large-aperture telescope requires thin, lightweight mirrors; ...

  18. X-Ray Tools for Battery Development and Testing: Case Studies...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    X-Ray Tools for Battery Development and Testing: Case Studies Case studies of the use of X-ray techniques for battery development and testing at the Advanced Photon Source PDF icon...

  19. Analysis and Interpretation of Hard X-ray Emission fromthe Bullet...

    Office of Scientific and Technical Information (OSTI)

    in the Extreme Ultraviolet and Hard X-ray ranges have provided for more powerful tools for the investigation of this phenomenon. Detection of hard X-rays in the 20 to 100...

  20. Best X-Ray Tools for Battery Development and Testing | Argonne...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Best X-Ray Tools for Battery Development and Testing Argonne's Advanced Photon Source has a suite of best-in-class X-ray techniques and lab space to tackle the most difficult...

  1. X-Ray Spectroscopy of the Mn(4) Ca Cluster in the Water-Oxidation...

    Office of Scientific and Technical Information (OSTI)

    X-Ray Spectroscopy of the Mn(4) Ca Cluster in the Water-Oxidation Complex of Photosystem II Citation Details In-Document Search Title: X-Ray Spectroscopy of the Mn(4) Ca Cluster in...

  2. Advanced X-ray Optics Metrology for Nanofocusing and Coherence Preservation

    E-Print Network [OSTI]

    Goldberg, Kenneth A.

    2008-01-01

    workshop: “Advanced X-Ray Optics Metrology for Nano-focusinglight sources if beamline optics won’t be available toTitled, “Advanced X-Ray Optics Metrology for Nano-focusing

  3. The adaptive x-ray optics project at the Lawrence Livermore National...

    Office of Scientific and Technical Information (OSTI)

    The adaptive x-ray optics project at the Lawrence Livermore National Laboratory Citation Details In-Document Search Title: The adaptive x-ray optics project at the Lawrence...

  4. Automated suppression of errors in LTP-II slope measurements with x-ray optics

    E-Print Network [OSTI]

    Ali, Zulfiqar

    2012-01-01

    precise reflective X-ray optics,” Nucl. Instrum. and Methods70 (2001). [2] P. Z. Takacs, “X- ray optics metrology,” in [Handbook of Optics], 3rd ed. , Vol. V, M. Bass, Ed. ,

  5. Bendable X-ray Optics at the ALS: Design, Tuning, Performance and Applications

    E-Print Network [OSTI]

    Yashchuk, Valeriy V.; Advanced Light Source, Lawrence Berkeley National Laboratory

    2008-01-01

    BENDABLE X-RAY OPTICS AT THE ALS: DESIGN, TUNING,ALS) of bendable x- ray optics widely used for focusing ofAn example of a bendable optic used at ALS beamline 5.0.2.

  6. Development of at-wavelength metrology for x-ray optics at the ALS

    E-Print Network [OSTI]

    Yashchuk, Valeriy V.

    2010-01-01

    alignment of bendable x-ray optics to realize diffraction-Bass (Ed. ), Handbook of Optics, third ed. , vol. V, ch. 46,wavelength metrology for x-ray optics at the ALS* Valeriy V.

  7. Development of procedures for refurbishing x-ray optics at the Advanced Light Source

    E-Print Network [OSTI]

    Yashchuk, Valeriy V.

    2013-01-01

    and Setting of Bendable Optics for Diffraction- Limitedof Soft X-Rays,” Abstract to SPIE Optics and Photonics 2012,Metrology for X-Ray and EUV Optics IV (San Diego, August 12-

  8. A versatile high-resolution x-ray imager (HRXI) for laser-plasma...

    Office of Scientific and Technical Information (OSTI)

    x-ray imager (HRXI) devoted to laser-plasma experiments combines two state-of-the-art technologies developed in France: a high-resolution x-ray microscope and a high-speed...

  9. Scanning standing-wave illumination microscopy : a path to nanometer resolution in X-ray microscopy

    E-Print Network [OSTI]

    Hong, Stanley Seokjong, 1977-

    2005-01-01

    X-ray microscopy can potentially combine the advantages of light microscopy with resolution approaching that of electron microscopy. In theory, x-ray microscopes can image unsectioned hydrated cells with nanometer resolution. ...

  10. Small-Angle X-Ray Scattering From RNA, Proteins, And Protein...

    Office of Scientific and Technical Information (OSTI)

    Small-Angle X-Ray Scattering From RNA, Proteins, And Protein Complexes Citation Details In-Document Search Title: Small-Angle X-Ray Scattering From RNA, Proteins, And Protein...

  11. An Eulerian CFD Model and X-ray Radiography for Coupled Nozzle...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Model and X-ray Radiography for Coupled Nozzle Flow and Spray in Internal Combustion Engines Title An Eulerian CFD Model and X-ray Radiography for Coupled Nozzle Flow and Spray in...

  12. The accretion process in neutron-star low-mass X-ray binaries

    E-Print Network [OSTI]

    Lin, Dacheng

    2009-01-01

    There had been long-standing fundamental problems in the spectral studies of accreting neutron stars (NSs) in low-mass X-ray binaries involving the X-ray spectral decomposition, the relations between subtypes (mainly atoll ...

  13. Generation of femtosecond to sub-femtosecond x-ray pulses in...

    Office of Scientific and Technical Information (OSTI)

    x-ray pulses in free-electron lasers Citation Details In-Document Search Title: Generation of femtosecond to sub-femtosecond x-ray pulses in free-electron lasers Abstract is...

  14. Design and development of a 3D X-ray microscope

    E-Print Network [OSTI]

    Brayanov, Jordan, 1981-

    2006-01-01

    The rapid development of needle-free injection systems demands better and faster imaging systems, capable of imaging the transient and steady state response of an injection into real tissue. X-ray radiography, x-ray ...

  15. X-ray and neutron scattering from nano-mgantic clusters | The...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    X-ray and neutron scattering from nano-mgantic clusters The student will participate in hands on X-ray scattering experiments on bio-inspired inorganic materials (i.e., magnetic...

  16. In Situ X-Ray Scattering Helps Optimize Printed Solar Cells

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    In Situ X-Ray Scattering Helps Optimize Printed Solar Cells In Situ X-Ray Scattering Helps Optimize Printed Solar Cells Print Wednesday, 25 February 2015 00:00 Plastic solar cells...

  17. X-rayEmissionfromMassiveStars: UsingEmissionLineProfilestoConstrainWind

    E-Print Network [OSTI]

    Cohen, David

    X-rayEmissionfromMassiveStars: UsingEmissionLineProfilestoConstrainWind Kinematics? Pup:windX-rays,butlessabsorptionthanexpected OriandOri:similarsituation,verylittlewind absorption). Cyclicaland stochastic variabilityis seeninmost hotstars'winds #12

  18. IMPULSIVE PHASE CORONAL HARD X-RAY SOURCES IN AN X3.9 CLASS SOLAR...

    Office of Scientific and Technical Information (OSTI)

    IMPULSIVE PHASE CORONAL HARD X-RAY SOURCES IN AN X3.9 CLASS SOLAR FLARE Citation Details In-Document Search Title: IMPULSIVE PHASE CORONAL HARD X-RAY SOURCES IN AN X3.9 CLASS SOLAR...

  19. Non-Destructive X-ray Measurement of Soot, Ash, Washcoat and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    X-ray Measurement of Soot, Ash, Washcoat and Regeneration Damage for DPFs Non-Destructive X-ray Measurement of Soot, Ash, Washcoat and Regeneration Damage for DPFs New commercially...

  20. Studies of a Linac Driver for a High Repetition Rate X-Ray FEL

    E-Print Network [OSTI]

    Venturini, M.

    2012-01-01

    REPETITION RATE X-RAY FEL ? M. Venturini † , J. Corlett, L.support a high repetition rate FEL operating in the soft x-of high-repetition rate FEL machine generat- ing soft x-rays

  1. Technique for the Generation of Attosecond X-Ray Pulses Using an FEL

    E-Print Network [OSTI]

    Penn, G.; Zholents, A.A.

    2005-01-01

    experiments at a X-ray SASE FEL”, Optics Communications,considerations for a SASE X-ray FEL”, Nucl. Instr. Methodsa fully 3D time-dependent FEL simulation code”, Nucl. Instr.

  2. Ultra-high Resolution Optics for EUV and Soft X-ray Inelastic Scattering

    E-Print Network [OSTI]

    Voronov, Dmitry L.

    2010-01-01

    16. Yu. Shvyd’ko, X-Ray Optics, Berlin: Springer-Verlag,Ultra-high Resolution Optics for EUV and Soft X-rayspectral resolution soft x-ray optics. Conventionally in the

  3. Lensless Imaging of Whole Biological Cells with Soft X-Rays

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    problems. Even the best x-ray microscope lenses (concentric circles of metal known as Fresnel zone plates) cannot focus x-rays with high efficiency. To get an image means using...

  4. Lithium fluoride (LiF) crystal for parametric X-ray (PXR) production

    E-Print Network [OSTI]

    Danon, Yaron

    Lithium fluoride (LiF) crystal for parametric X-ray (PXR) production B. Sones *, Y. Danon, R 2004 Abstract Parametric X-ray (PXR) production is reported using lithium fluoride (LiF) as a target

  5. In Operando Soft X-ray Spectroscopy of 3D Graphene Supercapacitor...

    Office of Scientific and Technical Information (OSTI)

    In Operando Soft X-ray Spectroscopy of 3D Graphene Supercapacitor Electrodes Citation Details In-Document Search Title: In Operando Soft X-ray Spectroscopy of 3D Graphene...

  6. X-ray Standing Wave Mapping of Graphene/SiC NSF Grant # 1121262

    E-Print Network [OSTI]

    Shahriar, Selim

    MRSEC X-ray Standing Wave Mapping of Graphene/SiC NSF Grant # 1121262 J. Emery1, B. Detlefs2, H. In order to understand the nature of this influential buffer layer, we employed X-ray Standing wave

  7. Standing-wave excited soft x-ray photoemission microscopy: application to Co microdot magnetic arrays

    E-Print Network [OSTI]

    Gray, Alexander

    2011-01-01

    Standing-wave excited soft x-ray photoemission microscopy:excitation with soft x-ray standing-waves generated by Braggmirror substrate. Standing wave is moved vertically through

  8. Energy feedback from x-ray binaries in the early universe

    E-Print Network [OSTI]

    2013-01-01

    X-RAY BINARIES IN THE EARLY UNIVERSE T. Fragos 1,2 , B. D.heating and reionization of the early universe. The two mostX-ray photons in the universe are active galactic nuclei (

  9. Streak cameras for soft x-ray and optical radiation

    SciTech Connect (OSTI)

    Medecki, H.

    1983-09-01

    The principal component of a streak camera is the image converter tube. A slit-shaped photocathode transforms the radiation into a proportional emission of electrons. An electron - optics arrangement accelerates the electrons and projects them into a phosphor screen creating the image of the slit. A pair of deflection plates deflects the electronic beam along a direction perpendicular to the main dimension of the slit. Different portions of the phosphor screen show the instantaneous image of the slit with brightness proportional to the number of emitted electrons and, consequently, to the intensity of the radiation. For our x-ray streak cameras, we use the RCA C73435A image conventer tube intended for the measurement of the radiation of light and modified to have an x-ray sensitive photocathode. Practical considerations lead to the use of transparent rather than reflecting photocathodes. Several of these camera tubes are briefly described.

  10. Background-reducing X-ray multilayer mirror

    DOE Patents [OSTI]

    Bloch, Jeffrey J. (Los Alamos, NM); Roussel-Dupre', Diane (Los Alamos, NM); Smith, Barham W. (Los Alamos, NM)

    1992-01-01

    Background-reducing x-ray multilayer mirror. A multiple-layer "wavetrap" deposited over the surface of a layered, synthetic-microstructure soft x-ray mirror optimized for reflectivity at chosen wavelengths is disclosed for reducing the reflectivity of undesired, longer wavelength incident radiation incident thereon. In three separate mirror designs employing an alternating molybdenum and silicon layered, mirrored structure overlaid by two layers of a molybdenum/silicon pair anti-reflection coating, reflectivities of near normal incidence 133, 171, and 186 .ANG. wavelengths have been optimized, while that at 304 .ANG. has been minimized. The optimization process involves the choice of materials, the composition of the layer/pairs as well as the number thereof, and the distance therebetween for the mirror, and the simultaneous choice of materials, the composition of the layer/pairs, and their number and distance for the "wavetrap."

  11. X-ray reflection spectra from ionized slabs

    E-Print Network [OSTI]

    R. R. Ross; A. C. Fabian; A. J. Young

    1999-02-23

    X-ray reflection spectra are an important component in the X-ray spectra of many active galactic nuclei and Galactic black hole candidates. It is likely that reflection takes place from highly ionized surfaces of the accretion disc in some cases. This can lead to strong Comptonization of the emergent iron, and other, absorption and emission features. We present such reflection spectra here, computed in a self-consistent manner with the method described by Ross and Fabian. In particular we emphasise the range where the ionization parameter (the flux to density ratio) \\xi is around and above 10^4. Such spectra may be relevant to the observed spectral features found in black hole candidates such as Cygnus X-1 in the low/hard state.

  12. A compact x-ray free electron laser

    SciTech Connect (OSTI)

    Barletta, W.A. . Center for Advanced Accelerators Physics Lawrence Livermore National Lab., CA ); Atac, M.; Cline, D.B.; Kolonko, J. . Center for Advanced Accelerators Physics); Bhowmik, A.; Bobbs, B.; Cover, R.A.; Dixon, F.P.; Rakowsky, G. . Rocketdyne Div.); Gallardo

    1988-01-01

    We present a design concept and simulation of the performance of a compact x-ray, free electron laser driven by ultra-high gradient rf-linacs. The accelerator design is based on recent advances in high gradient technology by a LLNL/SLAC/LBL collaboration and on the development of bright, high current electron sources by BNL and LANL. The GeV electron beams generated with such accelerators can be converted to soft x-rays in the range from 2--10 nm by passage through short period, high field strength wigglers as are being designed at Rocketdyne Linear light sources of this type can produce trains of picosecond (or shorter) pulses of extremely high spectral brilliance suitablee for flash holography of biological specimens in vivo and for studies of fast chemical reactions. 12 refs., 8 figs., 4 tabs.

  13. Fiber fed x-ray/gamma ray imaging apparatus

    DOE Patents [OSTI]

    Hailey, Charles J. (San Francisco, CA); Ziock, Klaus-Peter (Livermore, CA)

    1992-01-01

    X-ray/gamma ray imaging apparatus is disclosed for detecting the position, energy, and intensity of x-ray/gamma ray radiation comprising scintillation means disposed in the path of such radiation and capable of generating photons in response to such radiation; first photodetection means optically bonded to the scintillation means and capable of generating an electrical signal indicative of the intensity, and energy of the radiation detected by the scintillation means; second photodetection means capable of generating an electrical signal indicative of the position of the radiation in the radiation pattern; and means for optically coupling the scintillation means to the second photodetection means. The photodetection means are electrically connected to control and storage means which may also be used to screen out noise by rejecting a signal from one photodetection means not synchronized to a signal from the other photodetection means; and also to screen out signals from scattered radiation.

  14. Phase Effects on Mesoscale Object X-ray Absorption Images

    SciTech Connect (OSTI)

    Martz, Jr., H E; Aufderheide, M B; Barty, A; Lehman, S K; Kozioziemski, B J; Schneberk, D J

    2004-09-24

    At Lawrence Livermore National Laboratory particular emphasis is being placed on the nondestructive characterization (NDC) of 'mesoscale' objects.[Martz and Albrecht 2003] We define mesoscale objects as objects that have mm extent with {micro}m features. Here we confine our discussions to x-ray imaging methods applicable to mesoscale object characterization. The goal is object recovery algorithms including phase to enable emerging high-spatial resolution x-ray imaging methods to ''see'' inside or image mesoscale-size materials and objects. To be successful our imaging characterization effort must be able to recover the object function to one micrometer or better spatial resolution over a few millimeters field-of-view with very high contrast.

  15. Nucleosynthesis in Type I X-ray Bursts

    E-Print Network [OSTI]

    A. Parikh; J. José; G. Sala; C. Iliadis

    2012-11-26

    Type I X-ray bursts are thermonuclear explosions that occur in the envelopes of accreting neutron stars. Detailed observations of these phenomena have prompted numerous studies in theoretical astrophysics and experimental nuclear physics since their discovery over 35 years ago. In this review, we begin by discussing key observational features of these phenomena that may be sensitive to the particular patterns of nucleosynthesis from the associated thermonuclear burning. We then summarize efforts to model type I X-ray bursts, with emphasis on determining the nuclear physics processes involved throughout these bursts. We discuss and evaluate limitations in the models, particularly with regard to key uncertainties in the nuclear physics input. Finally, we examine recent, relevant experimental measurements and outline future prospects to improve our understanding of these unique environments from observational, theoretical and experimental perspectives.

  16. Towards phasing using high X-ray intensity

    SciTech Connect (OSTI)

    Galli, Lorenzo; Son, Sang -Kil; Barends, Thomas R. M.; White, Thomas A.; Barty, Anton; Botha, Sabine; Boutet, Sébastien; Caleman, Carl; Doak, R. Bruce; Nanao, Max H.; Nass, Karol; Shoeman, Robert L.; Timneanu, Nicusor; Santra, Robin; Schlichting, Ilme; Chapman, Henry N.

    2015-09-30

    X-ray free-electron lasers (XFELs) show great promise for macromolecular structure determination from sub-micrometre-sized crystals, using the emerging method of serial femtosecond crystallography. The extreme brightness of the XFEL radiation can multiply ionize most, if not all, atoms in a protein, causing their scattering factors to change during the pulse, with a preferential `bleaching' of heavy atoms. This paper investigates the effects of electronic damage on experimental data collected from a Gd derivative of lysozyme microcrystals at different X-ray intensities, and the degree of ionization of Gd atoms is quantified from phased difference Fourier maps. In conclusion, a pattern sorting scheme is proposed to maximize the ionization contrast and the way in which the local electronic damage can be used for a new experimental phasing method is discussed.

  17. Optical Klystron Enhancement to SASE X-ray FELs

    SciTech Connect (OSTI)

    Ding, Yuantao; Emma, Paul; Huang, Zhirong; Kumar, Vinit

    2006-04-07

    The optical klystron enhancement to self-amplified spontaneous emission (SASE) free electron lasers (FELs) is studied in theory and in simulations. In contrast to a seeded FEL, the optical klystron gain in a SASE FEL is not sensitive to any phase mismatch between the radiation and the microbunched electron beam. The FEL performance with the addition of four optical klystrons located at the undulator long breaks in the Linac Coherent Light Source (LCLS) shows significant improvement if the uncorrelated energy spread at the undulator entrance can be controlled to a very small level. In addition, FEL saturation at shorter x-ray wavelengths (around 1.0 A) within the LCLS undulator length becomes possible. We also discuss the application of the optical klystron in a compact x-ray FEL design that employs relatively low electron beam energy together with a shorter-period undulator.

  18. Towards phasing using high X-ray intensity

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Galli, Lorenzo; Son, Sang -Kil; Barends, Thomas R. M.; White, Thomas A.; Barty, Anton; Botha, Sabine; Boutet, Sébastien; Caleman, Carl; Doak, R. Bruce; Nanao, Max H.; et al

    2015-09-30

    X-ray free-electron lasers (XFELs) show great promise for macromolecular structure determination from sub-micrometre-sized crystals, using the emerging method of serial femtosecond crystallography. The extreme brightness of the XFEL radiation can multiply ionize most, if not all, atoms in a protein, causing their scattering factors to change during the pulse, with a preferential `bleaching' of heavy atoms. This paper investigates the effects of electronic damage on experimental data collected from a Gd derivative of lysozyme microcrystals at different X-ray intensities, and the degree of ionization of Gd atoms is quantified from phased difference Fourier maps. In conclusion, a pattern sorting schememore »is proposed to maximize the ionization contrast and the way in which the local electronic damage can be used for a new experimental phasing method is discussed.« less

  19. The Norma arm region Chandra survey catalog: X-ray populations in the spiral arms

    SciTech Connect (OSTI)

    Fornasini, Francesca M. [Astronomy Department, University of California, 601 Campbell Hall, Berkeley, CA 94720 (United States); Tomsick, John A.; Bodaghee, Arash; Krivonos, Roman A. [Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720 (United States); An, Hongjun [Department of Physics, McGill University, Rutherford Physics Building, 3600 University Street, Montreal, QC H3A 2T8 (Canada); Rahoui, Farid [European Southern Observatory, Karl Schwarzschild-Strasse 2, D-85748 Garching bei München (Germany); Gotthelf, Eric V. [Columbia Astrophysics Laboratory, Columbia University, 550 West 120th Street, New York, NY 10027 (United States); Bauer, Franz E. [Instituto de Astrofísica, Facultad de Física, Pontificia Universidad Católica de Chile, 306, Santiago 22 (Chile); Stern, Daniel, E-mail: f.fornasini@berkeley.edu [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, MS 169-506, Pasadena, CA 91109 (United States)

    2014-12-01

    We present a catalog of 1415 X-ray sources identified in the Norma Arm Region Chandra Survey (NARCS), which covers a 2° × 0.°8 region in the direction of the Norma spiral arm to a depth of ?20 ks. Of these sources, 1130 are point-like sources detected with ?3? confidence in at least one of three energy bands (0.5-10, 0.5-2, and 2-10 keV), five have extended emission, and the remainder are detected at low significance. Since most sources have too few counts to permit individual classification, they are divided into five spectral groups defined by their quantile properties. We analyze stacked spectra of X-ray sources within each group, in conjunction with their fluxes, variability, and infrared counterparts, to identify the dominant populations in our survey. We find that ?50% of our sources are foreground sources located within 1-2 kpc, which is consistent with expectations from previous surveys. Approximately 20% of sources are likely located in the proximity of the Scutum-Crux and near Norma arm, while 30% are more distant, in the proximity of the far Norma arm or beyond. We argue that a mixture of magnetic and nonmagnetic cataclysmic variables dominates the Scutum-Crux and near Norma arms, while intermediate polars and high-mass stars (isolated or in binaries) dominate the far Norma arm. We also present the cumulative number count distribution for sources in our survey that are detected in the hard energy band. A population of very hard sources in the vicinity of the far Norma arm and active galactic nuclei dominate the hard X-ray emission down to f{sub X} ? 10{sup –14} erg cm{sup –2} s{sup –1}, but the distribution curve flattens at fainter fluxes. We find good agreement between the observed distribution and predictions based on other surveys.

  20. X-RAY METHODS FOR THE CHEMICAL CHARACTERIZATION OF ATMOSPHERIC AEROSOLS

    E-Print Network [OSTI]

    Jaklevic, J.M.

    2010-01-01

    for the routine analysis of air pollution samples, itof x-ray methods to the analysis of air particulate samples.

  1. Non-Destructive X-ray Measurement of Soot, Ash, Washcoat and Regeneration Damage for DPFs

    Broader source: Energy.gov [DOE]

    New commercially avaliable non-destructive x-ray techniques are used to make measurements on diesel particulate filters.

  2. Final report: high resolution lensless 3D imaging of nanostructures with coherent x-rays

    SciTech Connect (OSTI)

    Jacobsen, Chris

    2014-12-07

    Final report on the project "High resolution lensless 3D imaging of nanostructures with coherent x-rays"

  3. Statistical Analysis of X-ray Speckle at the NSLS

    E-Print Network [OSTI]

    Ophelia K. C. Tsui; S. G. J. Mochrie; L. E. Berman

    1997-09-30

    We report a statistical analysis of the static speckle produced by illuminating a disordered aerogel sample by a nominally coherent x-ray beam at wiggler beamline X25 at the National Synchrotron Light Source. The results of the analysis allow us to determine that the coherence delivered to the X25 hutch is within 35% of what is expected. The rate of coherent photons is approximately two times smaller than expected on the basis of the X25 wiggler source brilliance.

  4. Modelling the radio to X-ray SED of galaxies

    E-Print Network [OSTI]

    Laura Silva; Alessandro Bressan; Gian Luigi Granato; Pasquale Panuzzo

    2001-06-07

    We present our model to interpret the SED of galaxies. The model for the UV to sub-mm SED is already well established (Silva et al 1998). We remind here its main features and show some applications. Recently we have extended the model to the radio range (Bressan et al 2001), and we have started to include the X-ray emission from the stellar component.

  5. Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube

    SciTech Connect (OSTI)

    Kayser, Y.; B?achucki, W.; Dousse, J.-Cl.; Hoszowska, J.; Neff, M.; Romano, V.

    2014-04-15

    The high-resolution von Hamos bent crystal spectrometer of the University of Fribourg was upgraded with a focused X-ray beam source with the aim of performing micro-sized X-ray fluorescence (XRF) measurements in the laboratory. The focused X-ray beam source integrates a collimating optics mounted on a low-power micro-spot X-ray tube and a focusing polycapillary half-lens placed in front of the sample. The performances of the setup were probed in terms of spatial and energy resolution. In particular, the fluorescence intensity and energy resolution of the von Hamos spectrometer equipped with the novel micro-focused X-ray source and a standard high-power water-cooled X-ray tube were compared. The XRF analysis capability of the new setup was assessed by measuring the dopant distribution within the core of Er-doped SiO{sub 2} optical fibers.

  6. INTEGRAL monitoring of unusually long X-ray bursts

    E-Print Network [OSTI]

    J. Chenevez; M. Falanga; E. Kuulkers; S. Brandt; N. lund; A. Cumming

    2008-11-06

    X-ray bursts are thermonuclear explosions on the surface of accreting neutron stars in low mass X-ray binaries. As most of the known X-ray bursters are frequently observed by INTEGRAL, an international collaboration have been taking advantage of its instrumentation to specifically monitor the occurrence of exceptional burst events lasting more than ~10 minutes. Half of the so-called intermediate long bursts registered so far have been observed by INTEGRAL. The goal is to derive a comprehensive picture of the relationship between the nuclear ignition processes and the accretion states of the system leading up to such long bursts. Depending on the composition of the accreted material, these bursts may be explained by either the unstable burning of a large pile of mixed hydrogen and helium, or the ignition of a thick pure helium layer. Intermediate long bursts are particularly expected to occur at very low accretion rates and make possible to study the transition from a hydrogen-rich bursting regime to a pure helium regime.

  7. X-ray Microspectroscopy and Chemical Reactions in Soil Microsites

    SciTech Connect (OSTI)

    D Hesterberg; M Duff; J Dixon; M Vepraskas

    2011-12-31

    Soils provide long-term storage of environmental contaminants, which helps to protect water and air quality and diminishes negative impacts of contaminants on human and ecosystem health. Characterizing solid-phase chemical species in highly complex matrices is essential for developing principles that can be broadly applied to the wide range of notoriously heterogeneous soils occurring at the earth's surface. In the context of historical developments in soil analytical techniques, we describe applications of bulk-sample and spatially resolved synchrotron X-ray absorption spectroscopy (XAS) for characterizing chemical species of contaminants in soils, and for determining the uniqueness of trace-element reactivity in different soil microsites. Spatially resolved X-ray techniques provide opportunities for following chemical changes within soil microsites that serve as highly localized chemical micro- (or nano-)reactors of unique composition. An example of this microreactor concept is shown for micro-X-ray absorption near edge structure analysis of metal sulfide oxidation in a contaminated soil. One research challenge is to use information and principles developed from microscale soil chemistry for predicting macroscale and field-scale behavior of soil contaminants.

  8. A Search for X-ray Counterparts of Radio Pulsars

    E-Print Network [OSTI]

    Prinz, Tobias

    2015-01-01

    We describe a systematic search for X-ray counterparts of radio pulsars. The search was accomplished by cross-correlating the radio timing positions of all radio pulsars from the ATNF pulsar database (version 1.54) with archival XMM-Newton and Chandra observations publicly released by August 1st 2015. In total, 171 of the archival XMM-Newton observations and 215 of the archival Chandra datasets where found to have a radio pulsar serendipitously in the field of view. From the 283 radio pulsars covered by these datasets we identified 19 previously undetected X-ray counterparts. For 6 of them the statistics was sufficient to model the energy spectrum with one- or two-component models. For the remaining new detections and for those pulsars for which we determined an upper limit to their counting rate we computed the energy flux by assuming a Crab-like spectrum. Additionally, we derived upper limits on the neutron stars' surface temperature and on the non-thermal X-ray efficiency for those pulsars for which the sp...

  9. GALACTIC ULTRACOMPACT X-RAY BINARIES: EMPIRICAL LUMINOSITIES

    SciTech Connect (OSTI)

    Cartwright, T. F.; Engel, M. C.; Heinke, C. O.; Sivakoff, G. R.; Berger, J. J.; Gladstone, J. C.; Ivanova, N., E-mail: heinke@ualberta.ca [Physics Department, 4-183 CCIS, University of Alberta, Edmonton, AB T6G 2E1 (Canada)

    2013-05-10

    Ultracompact X-ray binaries (UCXBs) are thought to have relatively simple binary evolution post-contact, leading to clear predictions of their luminosity function. We test these predictions by studying the long-term behavior of known UCXBs in our Galaxy, principally using data from the MAXI All-Sky Survey and the Galactic bulge scans with RXTE's Proportional Counter Array instrument. Strong luminosity variations are common (and well documented) among persistent UCXBs, which requires an explanation other than the disk instability mechanism. We measure the luminosity function of known UCXBs in the Milky Way, which extends to lower luminosities than some proposed theoretical luminosity functions of UCXBs. The difference between field and globular cluster (GC) X-ray luminosity functions in other galaxies cannot be explained by an increased fraction of UCXBs in GCs. Instead, our measured luminosity function suggests that UCXBs only make up a small fraction of the X-ray binaries above a few Multiplication-Sign 10{sup 36} erg s{sup -1} in both old field populations and GCs.

  10. Soft X-ray emission in flaring coronal loops

    E-Print Network [OSTI]

    Pinto, R F; Brun, A S

    2014-01-01

    Solar flares are associated with intense soft X-ray emission generated by the hot flaring plasma in coronal magnetic loops. Kink unstable twisted flux-ropes provide a source of magnetic energy which can be released impulsively and account for the heating of the plasma in flares. We investigate the temporal, spectral and spatial evolution of the properties of the thermal X-ray emission produced in such kink-unstable magnetic flux-ropes using a series of MHD simulations. We deduce emission diagnostics and their temporal evolution and discuss the results of the simulations with respect to observations. The numerical setup used consists of a highly twisted loop embedded in a region of uniform and untwisted background coronal magnetic field. We let the kink instability develop, compute the evolution of the plasma properties in the loop (density, temperature) and deduce the X-ray emission properties of the plasma during the whole flaring episode. During the initial phase of the instability plasma heating is mostly ...

  11. THz Pump and X-Ray Probe Development at LCLS

    SciTech Connect (OSTI)

    Fisher, Alan S; /SLAC, LCLS; Durr, Hermann; /SIMES, Stanford /SLAC, PULSE; Lindenberg, Aaron; Stanford U., Materials Sci.Dept.; /SIMES, Stanford /SLAC, PULSE; Reis, David; /SIMES, Stanford /SLAC, PULSE /Stanford U., Dept. Appl. Phys.; Frisch, Josef; Loos, Henrik; Petree, Mark; /SLAC, LCLS; Daranciang, Dan; /Stanford U., Chem. Dept.; Fuchs, Matthias; /SLAC, PULSE; Ghimire, Shambhu; /SLAC, PULSE; Goodfellow, John; /Stanford U., Materials Sci. Dept.

    2011-11-08

    We report on measurements of broadband, intense, coherent transition radiation at terahertz frequencies, generated as the highly compressed electron bunches in Linear Coherent Light Source (LCLS) pass through a thin metal foil. The foil is inserted at 45{sup o} to the electron beam, 31 m downstream of the undulator. The THz emission passes downward through a diamond window to an optical table below the beamline. A fully compressed 350-pC bunch produces up to 0.5 mJ in a nearly half-cycle pulse of 50 fs FWHM with a spectrum peaking at 10 THz. We estimate a peak field at the focus of over 2.5 GV/m. A 20-fs Ti:sapphire laser oscillator has recently been installed for electro-optic measurements. We are developing plans to add an x-ray probe to this THz pump, by diffracting FEL x rays onto the table with a thin silicon crystal. The x rays would arrive with an adjustable time delay after the THz. This will provide a rapid start to user studies of materials excited by intense single-cycle pulses and will serve as a step toward a THz transport line for LCLS-II.

  12. Size dependence of solar X-ray flare properties

    E-Print Network [OSTI]

    Marina Battaglia; Paolo C. Grigis; Arnold O. Benz

    2005-05-09

    Non-thermal and thermal parameters of 85 solar flares of GOES class B1 to M6 (background subtracted classes A1 to M6) have been compared to each other. The hard X-ray flux has been measured by RHESSI and a spectral fitting provided flux and spectral index of the non-thermal emission, as well as temperature and emission measure of the thermal emission. The soft X-ray flux was taken from GOES measurements. We find a linear correlation in a double logarithmic plot between the non-thermal flux and the spectral index. The higher the acceleration rate of a flare, the harder the non-thermal electron distribution. The relation is similar to the one found by a comparison of the same parameters from several sub-peaks of a single flare. Thus small flares behave like small subpeaks of large flares. Thermal flare properties such as temperature, emission measure and the soft X-ray flux also correlate with peak non-thermal flux. A large non-thermal peak flux entails an enhancement in both thermal parameters. The relation between spectral index and the non-thermal flux is an intrinsic feature of the particle acceleration process, depending on flare size. This property affects the reported frequency distribution of flare energies.

  13. The hidden X-ray breaks in afterglow light curves

    SciTech Connect (OSTI)

    Curran, P. A.; Wijers, R. A. M. J.; Horst, A. J. van der; Starling, R. L. C.

    2008-05-22

    Gamma-Ray Burst (GRB) afterglow observations in the Swift era have a perceived lack of achromatic jet breaks compared to the BeppoSAX, or pre-Swift era. Specifically, relatively few breaks, consistent with jet breaks, are observed in the X-ray light curves of these bursts. If these breaks are truly missing, it has serious consequences for the interpretation of GRB jet collimation and energy requirements, and the use of GRBs as standard candles.Here we address the issue of X-ray breaks which are possibly 'hidden' and hence the light curves are misinterpreted as being single power-laws. We show how a number of precedents, including GRB 990510 and GRB 060206, exist for such hidden breaks and how, even with the well sampled light curves of the Swift era, these breaks may be left misidentified. We do so by synthesising X-ray light curves and finding general trends via Monte Carlo analysis. Furthermore, in light of these simulations, we discuss how to best identify achromatic breaks in afterglow light curves via multi-wavelength analysis.

  14. PAPER 1Simultaneous measurements of X rays and electrons during a pulsating aurora

    E-Print Network [OSTI]

    Østgaard, Nikolai

    PAPER 1Simultaneous measurements of X rays and electrons during a pulsating aurora N. Østgaard1 , J aurora. In this paper we focus on the observations of precipitating electrons and auroral X-rays. By using models it is possible to deduce the electron energy spectrum from X-ray measurements. Comparisons

  15. X-ray timing of the accreting millisecond pulsar SAX J1808.4-3658

    E-Print Network [OSTI]

    Hartman, Jacob M., Ph. D. Massachusetts Institute of Technology

    2007-01-01

    We present a 7 yr timing study of the 2.5 ms X-ray pulsar SAX J1808.4-3658, an X-ray transient with a recurrence time of =2 yr, using data from the Rossi X-ray Timing Explorer covering 4 transient outbursts (1998-2005). ...

  16. GENTLE IONISATION AND VIOLENT BREAK-UP OF MOLECULES USING SOFT X-RAYS

    E-Print Network [OSTI]

    Bapat, Bhas

    RRCAT Indore, June 2012 BHAS BAPAT (PRL, AHMEDABAD) BREAK-UP OF MOLECULES USING SOFT X-RAYS RRCAT INDORE INVESTIGATED RECENT RESULTS BHAS BAPAT (PRL, AHMEDABAD) BREAK-UP OF MOLECULES USING SOFT X-RAYS RRCAT INDORE-UP OF MOLECULES USING SOFT X-RAYS RRCAT INDORE, JUNE 2012 3 / 27 #12;INTRODUCTION MOLECULES A molecule may

  17. X-ray Spectroscopy of Massive Star Winds: Shocks, Mass-Loss Rates, and Clumping

    E-Print Network [OSTI]

    Cohen, David

    X-ray Spectroscopy of Massive Star Winds: Shocks, Mass-Loss Rates, and Clumping David Cohen X-rays A. wind-shock physics B. wind absorption: wind mass-loss rate C. with H-alpha: wind clumping Chandra resolved X-ray line profile spectroscopy of O star winds #12;Prior to 2000: only low-resolution X

  18. X-ray Spectroscopy of O Supergiant Winds: Shock Physics, Clumping, and Mass-Loss Rates

    E-Print Network [OSTI]

    Cohen, David

    X-ray Spectroscopy of O Supergiant Winds: Shock Physics, Clumping, and Mass-Loss Rates David Cohen-ray emission: wind shocks 1. X-ray constraints on the shocked wind plasma 2. X-ray absorption as a mass. Adiabatic shocks Open questions: very dense winds (WR stars); low density winds (B stars); magnetic OB stars

  19. ANALYSIS OF ASTM X-RAY SHRINKAGE RATING FOR STEEL CASTINGS

    E-Print Network [OSTI]

    Beckermann, Christoph

    1 ANALYSIS OF ASTM X-RAY SHRINKAGE RATING FOR STEEL CASTINGS Kent Carlson1 , Shouzhu Ou1 , Richard-ray shrinkage rating system for radiographs of steel castings. The first study evaluated the reliability and repeatability of x-ray shrinkage ratings through a statistical study of x-rays that were each rated seven

  20. Spectral Modeling of X-rays from Hot Star Winds Emma E. Wollman, Swarthmore College `09

    E-Print Network [OSTI]

    Cohen, David

    and absorption. Consequently, the more luminous a star is, the stronger the wind it can support. This wind-driving1 Spectral Modeling of X-rays from Hot Star Winds Emma E. Wollman, Swarthmore College `09 Prof x-ray spectra from Chandra's archive. Models of x-ray production in hot star winds predict broad

  1. National School on Neutron and X-ray Scattering June 14-28, 2014

    E-Print Network [OSTI]

    Kemner, Ken

    National School on Neutron and X-ray Scattering June 14-28, 2014 Argonne National Laboratory:00 Dinner Dinner Dinner Dinner Week 1 wrap-up Picnic #12;National School on Neutron and X-ray Scattering Restaurant 9:45 - 10:45 Lecture Interaction of X-rays and Neutrons with Matter Roger Pynn University

  2. National School on Neutron and X-ray Scattering August 10-24, 2013

    E-Print Network [OSTI]

    Kemner, Ken

    National School on Neutron and X-ray Scattering August 10-24, 2013 Argonne National Laboratory National Laboratory 3:15 ­ 3:30 Break #12;National School on Neutron and X-ray Scattering August 10 Dinner Week 1 wrap-up Picnic #12;National School on Neutron and X-ray Scattering August 10-24, 2012 Oak

  3. Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance

    E-Print Network [OSTI]

    Yashchuk, V. V.

    2010-01-01

    Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL:USA 4 Center for X-Ray Optics, Lawrence Berkeley Nationaldevelopment of bendable x-ray optics used for focusing of

  4. At-wavelength and optical metrology of bendable x-ray optics for nanofocusing at the ALS

    E-Print Network [OSTI]

    Yashchuk, Valeriy V.

    2009-01-01

    metrology of bendable x-ray optics for nanofocusing at theof super-high-quality x-ray optics with sub-microradianalignment of bendable x-ray optics to realize sub-100-nrad

  5. A Chandra X-ray Study of NGC 1068: II. The Luminous X-ray Source Population

    E-Print Network [OSTI]

    David A. Smith; Andrew S. Wilson

    2003-03-17

    We present an analysis of the compact X-ray source population in the Seyfert~2 galaxy NGC 1068, imaged with Chandra. We find a total of 84 compact sources, of which 66 are projected onto the galactic disk of NGC 1068. Spectra of the brightest sources have been modeled with both multi-color disk blackbody and power-law models. The power-law model provides the better description of the spectrum for most of these sources. Five sources have 0.4-8 keV intrinsic luminosities greater than 10^{39} erg/s, assuming that their emission is isotropic and that they are associated with NGC 1068. We refer to these sources as Intermediate Luminosity X-ray Objects (IXOs). If these five sources are X-ray binaries accreting with luminosities that are both sub-Eddington and isotropic, then the implied source masses are >7 solar masses, and so they are inferred to be black holes. The brightest source has a much harder spectrum (Gamma = 0.9\\pm0.1) than that found in Galactic black hole candidates and other IXOs. It also shows large-amplitude variability on both short-term and long-term timescales. The ratio of the number of sources with luminosities greater than 2.1 x 10^{38} erg/s in the 0.4-8 keV band to the rate of massive star formation is the same, to within a factor of two, for NGC 1068, the Antennae, NGC 5194 (the main galaxy in M51), and the Circinus galaxy. This suggests that the rate of production of X-ray binaries per massive star is approximately the same for galaxies with currently active star formation, including ``starbursts''.

  6. The Long Term Stability of Oscillations During Thermonuclear X-ray Bursts: Constraining the Binary X-ray Mass Function

    E-Print Network [OSTI]

    Tod E. Strohmayer; William Zhang; Jean H. Swank; Iosif Lapidus

    1998-06-18

    We report on the long term stability of the millisecond oscillations observed with the Rossi X-ray Timing Explorer (RXTE) during thermonuclear X-ray bursts from the low mass X-ray binaries (LMXB) 4U 1728-34 and 4U 1636-53. We show that bursts from 4U 1728-34 spanning more than 1.5 years have observed asymptotic oscillation periods which are within 0.2 microsec. of each other, well within the magnitude which could be produced by the orbital motion of the neutron star in a typical LMXB. This stability implies a timescale to change the oscillation period of > 23,000 years, suggesting a highly stable process such as stellar rotation as the oscillation mechanism. We show that period offsets in three distinct bursts from 4U 1636-53 can be plausibly interpreted as due to orbital motion of the neutron star in this 3.8 hour binary system. We discuss the constraints on the mass function which can in principle be derived using this technique.

  7. X-ray/UV variability and the origin of soft X-ray excess emission from II Zw 177

    E-Print Network [OSTI]

    Pal, Main; Misra, Ranjeev; Pawar, Pramod K

    2016-01-01

    We study X-ray and UV emission from the narrow-line Seyfert 1 galaxy II~Zw~177 using a $137\\ks$ long and another $13\\ks$ short \\xmm{} observation performed in 2012 and 2001, respectively. Both observations show soft X-ray excess emission contributing $76.9\\pm4.9\\%$ in 2012 and $58.8\\pm10.2\\%$ in 2001 in the $0.3-2\\kev$ band. We find that both blurred reflection from an ionized disc and Comptonized disc emission describe the observed soft excess well. Time-resolved spectroscopy on scales of $\\sim20\\ks$ reveals strong correlation between the soft excess and the powerlaw components. The fractional variability amplitude $F_{var}$ derived from EPIC-pn lightcurves at different energy bands is nearly constant ($F_{var} \\sim20\\%$). This is in contrast to other AGNs where the lack of short term variation in soft X-ray excess emission has been attributed to intense light bending in the framework of the "lamppost" model. Thus, the variations in powerlaw emission are most likely intrinsic to corona rather than just due t...

  8. On the Frequency Evolution of X-ray Brightness Oscillations During Thermonuclear X-ray Bursts: Evidence for Coherent Oscillations

    E-Print Network [OSTI]

    Tod E. Strohmayer; Craig B. Markwardt

    1999-03-03

    We investigate the time dependence of the frequency of X-ray brightness oscillations during thermonuclear bursts from several neutron star low mass X-ray binaries. We find that the oscillation frequencies in the cooling tails of X-ray bursts from 4U 1702-429 and 4U 1728-34 are well described by an exponential "chirp" model. With this model we demonstrate that the pulse trains in the cooling tails of many bursts are highly phase coherent, having oscillation quality factors as high as Q ~ 4000. We use this model of the frequency evolution to search sensitively for significant power at the harmonics and first sub-harmonic of the 330 and 363 Hz signals in bursts from 4U 1702-429 and 4U 1728-34, respectively, but find not evidence for significant power at any harmonic or the sub-harmonic. We argue that the high coherence favors stellar rotation as the source of the oscillations. We briefly discuss the frequency evolution in terms of rotational motion of an angular momentum conserving thermonuclear shell. we discuss how the limits on harmonic content can be used to infer properties of the neutron star.

  9. Resonant Soft X-Ray Contrast Variation Methods as Composition-Specific Probes of Thin Polymer Film Structure

    E-Print Network [OSTI]

    Welch, Cynthia F.

    2008-01-01

    traditional x-ray and neutron scattering techniques is oftentechniques used in neutron scattering, which requiretraditional x-ray and neutron scattering techniques. 16, 32

  10. Three New Long Period X-ray Pulsars Discovered in the Small Magellanic Cloud

    E-Print Network [OSTI]

    D. J. Macomb; D. W. Fox; R. C. Lamb; T. A. Prince

    2003-01-04

    The Small Magellanic Cloud is increasingly an invaluable laboratory for studying accreting and isolated X-ray pulsars. We add to the class of compact SMC objects by reporting the discovery of three new long period X-ray pulsars detected with the {\\it Chandra X-ray Observatory}. The pulsars, with periods of 152, 304 and 565 seconds, all show hard X-ray spectra over the range from 0.6 - 7.5 keV. The source positions of the three pulsars are consistent with known H-alpha emission sources, indicating they are likely to be Be type X-ray binary star systems.

  11. Investigation of the hard x-ray background in backlit pinhole imagers

    SciTech Connect (OSTI)

    Fein, J. R. Holloway, J. P.; Peebles, J. L.; Keiter, P. A.; Klein, S. R.; Kuranz, C. C.; Manuel, M. J.-E.; Drake, R. P.

    2014-11-15

    Hard x-rays from laser-produced hot electrons (>10 keV) in backlit pinhole imagers can give rise to a background signal that decreases signal dynamic range in radiographs. Consequently, significant uncertainties are introduced to the measured optical depth of imaged plasmas. Past experiments have demonstrated that hard x-rays are produced when hot electrons interact with the high-Z pinhole substrate used to collimate the softer He-? x-ray source. Results are presented from recent experiments performed on the OMEGA-60 laser to further study the production of hard x-rays in the pinhole substrate and how these x-rays contribute to the background signal in radiographs. Radiographic image plates measured hard x-rays from pinhole imagers with Mo, Sn, and Ta pinhole substrates. The variation in background signal between pinhole substrates provides evidence that much of this background comes from x-rays produced in the pinhole substrate itself. A Monte Carlo electron transport code was used to model x-ray production from hot electrons interacting in the pinhole substrate, as well as to model measurements of x-rays from the irradiated side of the targets, recorded by a bremsstrahlung x-ray spectrometer. Inconsistencies in inferred hot electron distributions between the different pinhole substrate materials demonstrate that additional sources of hot electrons beyond those modeled may produce hard x-rays in the pinhole substrate.

  12. Method and apparatus for molecular imaging using X-rays at resonance wavelengths

    DOE Patents [OSTI]

    Chapline, Jr., George F. (Alamo, CA)

    1985-01-01

    Holographic X-ray images are produced representing the molecular structure of a microscopic object, such as a living cell, by directing a beam of coherent X-rays upon the object to produce scattering of the X-rays by the object, producing interference on a recording medium between the scattered X-rays from the object and unscattered coherent X-rays and thereby producing holograms on the recording surface, and establishing the wavelength of the coherent X-rays to correspond with a molecular resonance of a constituent of such object and thereby greatly improving the contrast, sensitivity and resolution of the holograms as representations of molecular structures involving such constituent. For example, the coherent X-rays may be adjusted to the molecular resonant absorption line of nitrogen at about 401.3 eV to produce holographic images featuring molecular structures involving nitrogen.

  13. Optical observations of Be/X-ray transient system KS 1947+300

    E-Print Network [OSTI]

    U. Kiziloglu; A. Baykal; N. Kiziloglu

    2006-08-05

    ROTSE-IIId observations of the Be/X-ray transient system KS 1947+300 obtained between September 2004 and December 2005 make it possible to study the correlation between optical and X-ray activity. The optical outburst of 0.1 mag was accompanied by an increase in X-ray flux in 2004 observations. Strong correlation between the optical and X-ray light curves suggests that neutron star directly accretes from the outflowing material of Be star. The nearly zero time lag between X-ray and optical light curves suggests a heating of the disk of Be star by X-rays. No optical brightening and X-ray enhancement was seen in 2005 observations. There is no indication of the orbital modulation in the optical light curve.

  14. Self-detection of x-ray Fresnel transmittivity using photoelectron-induced gas ionization

    E-Print Network [OSTI]

    Stoupin, Stanislav

    2015-01-01

    Electric response of an x-ray mirror enclosed in a gas flow ionization chamber was studied under the conditions of total external reflection for hard x-rays. It is shown that the electric response of the system as a function of the incidence angle is defined by x-ray Fresnel transmittivity and photon-electron attenuation properties of the mirror material. A simple interpretation of quantum yield of the system is presented. The approach provides non-invasive in-situ diagnostics of hard x-ray optics, easy access to complementary x-ray transmittivity data in x-ray reflectivity experiments and can also pave the way to novel schemes for angle and energy resolving x-ray detectors.

  15. An X-ray Imaging Study of the Stellar Population in RCW49

    E-Print Network [OSTI]

    M. Tsujimoto; E. D. Feigelson; L. K. Townsley; P. S. Broos; K. V. Getman; J. Wang; G. P. Garmire; D. Baba; T. Nagayama; M. Tamura; E. B. Churchwell

    2007-05-04

    We present the results of a high-resolution X-ray imaging study of the stellar population in the Galactic massive star-forming region RCW49 and its central OB association Westerlund 2. We obtained a 40 ks X-ray image of a 17'x17' field using the Chandra X-ray Observatory and deep NIR images using the Infrared Survey Facility in a concentric 8'3x8'3 region. We detected 468 X-ray sources and identified optical, NIR, and Spitzer Space Telescope MIR counterparts for 379 of them. The unprecedented spatial resolution and sensitivity of the X-ray image, enhanced by optical and infrared imaging data, yielded the following results: (1) The central OB association Westerlund 2 is resolved for the first time in the X-ray band. X-ray emission is detected from all spectroscopically-identified early-type stars in this region. (2) Most (86%) X-ray sources with optical or infrared identifications are cluster members in comparison with a control field in the Galactic Plane. (3) A loose constraint (2--5 kpc) for the distance to RCW49 is derived from the mean X-ray luminosity of T Tauri stars. (4) The cluster X-ray population consists of low-mass pre--main-sequence and early-type stars as obtained from X-ray and NIR photometry. About 30 new OB star candidates are identified. (5) We estimate a cluster radius of 6'--7' based on the X-ray surface number density profiles. (6) A large fraction (90%) of cluster members are identified individually using complimentary X-ray and MIR excess emission. (7) The brightest five X-ray sources, two Wolf-Rayet stars and three O stars, have hard thermal spectra.

  16. Do X-ray Binary Spectral State Transition Luminosities Vary?

    E-Print Network [OSTI]

    Thomas J. Maccarone

    2003-08-02

    We tabulate the luminosities of the soft-to-hard state transitions of all X-ray binaries for which there exist good X-ray flux measurements at the time of the transition, good distance estimates, and good mass estimates for the compact star. We show that the state transition luminosities are at about 1-4% of the Eddington rate, markedly smaller than those typically quoted in the literature, with a mean value of 2%. Only the black hole candidate GRO J~1655-40 and the neutron star systems Aql X-1 and 4U 1728-34 have measured state transition luminosities inconsistent with this value at the 1$\\sigma$ level. GRO J~1655-40, in particular, shows a state transition luminosity below the mean value for the other sources at the $4\\sigma$ level. This result, combined with the known inner disk inclination angle (the disk is nearly parallel to the line of sight) from GRO J~1655-40's relativistic jets suggest that the hard X-ray emitting region in GRO J~1655-40 can have a velocity of no more than about $\\beta=0.68$, with a most likely value of about $\\beta=0.52$, and a minimum speed of $\\beta=0.45$, assuming that the variations in state transition luminosities are solely due to relativistic beaming effects. The variance in the state transition luminosities suggests an emission region with a velocity of $\\sim0.2c$. The results are discussed in terms of different emission models for the low/hard state. We also discuss the implications for measuring the dimensionless viscosity parameter $\\alpha$. We also find that if its state transitions occur at typical luminosities, then GX 339-4 is likely to be at a distance of at least 7.6 kpc, much further than typically quoted estimates.

  17. X-Ray Cargo Inspection: Status and Trends

    SciTech Connect (OSTI)

    Chen Gongyin; Bjorkholm, Paul; Fox, Timothy R.; Wilson, Zane; Bonsergent, Xavier

    2009-03-10

    Over the past several years, x-ray cargo inspection has experienced tremendous growth. There are several hundred systems in use world wide and a few new units are installed every week. Fielded systems are mostly located in north and West Africa, Middle East, Europe (especially Russia), East Asia, and South America. The majority of systems are powered by Varian M3, M6 or M9 Linac x-ray sources. The spatial resolution of these systems is typically 3-5 mm, penetration ranges from around 200 mm to 450 mm of steel and contrast sensitivity is typically 1-4%. Inspection throughput ranges from about 20 trucks per hour to 200 trucks per hour. Currently the systems are primarily used to fight import tax evasion and smuggling of controlled substances. There are a few clear trends: Imaging performance has been steadily improving; a variety of systems have been developed to fit different needs; also, there is a strong effort in material discrimination, or even identification and automatic detection. The last, but not least trend is a shift to security applications. The US government has launched major efforts such as CAARS and JINII to fight nuclear threat and systems that can automatically detect a small amount of high atomic number materials are being developed. This paper only covers RF linear accelerator based X-ray sources, which prevail in the industry. Induction accelerators (Betatrons) have some limited use in low-end imaging systems and high duty factors sources have recently been proposed for study.

  18. SPECTRAL PROPERTIES OF X-RAY BINARIES IN CENTAURUS A

    SciTech Connect (OSTI)

    Burke, Mark J.; Raychaudhury, Somak [School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom)] [School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Kraft, Ralph P.; Forman, William R.; Jones, Christine; Murray, Stephen S.; Birkinshaw, Mark; Evans, Daniel A.; Jordan, Andres [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)] [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Maccarone, Thomas J.; Croston, Judith H. [School of Physics and Astronomy, University of Southampton, Southampton SO17 1BJ (United Kingdom)] [School of Physics and Astronomy, University of Southampton, Southampton SO17 1BJ (United Kingdom); Brassington, Nicola J.; Hardcastle, Martin J.; Goodger, Joanna L. [School of Physics, Astronomy, and Mathematics, University of Hertfordshire, Hatfield AL10 9AB (United Kingdom)] [School of Physics, Astronomy, and Mathematics, University of Hertfordshire, Hatfield AL10 9AB (United Kingdom); Kainulainen, Jouni [Max-Planck-Institute for Astronomy, Koenigstuhl 17, D-69117 Heidelberg (Germany)] [Max-Planck-Institute for Astronomy, Koenigstuhl 17, D-69117 Heidelberg (Germany); Woodley, Kristin A. [Department of Physics and Astronomy, University of British Columbia, Vancouver BC V6T 1Z1 (Canada)] [Department of Physics and Astronomy, University of British Columbia, Vancouver BC V6T 1Z1 (Canada); Sivakoff, Gregory R. [Department of Physics, University of Alberta, Edmonton, Alberta T6G 2E1 (Canada)] [Department of Physics, University of Alberta, Edmonton, Alberta T6G 2E1 (Canada); Gilfanov, Marat [Max-Planck-Institut fuer Astrophysik, Karl-Schwarzschild-Str. 1, D-85741, Garching (Germany)] [Max-Planck-Institut fuer Astrophysik, Karl-Schwarzschild-Str. 1, D-85741, Garching (Germany); Sarazin, Craig L. [Department of Astronomy, University of Virginia, P.O. Box 400325, Charlottesville, VA 22904-4325 (United States)] [Department of Astronomy, University of Virginia, P.O. Box 400325, Charlottesville, VA 22904-4325 (United States); Voss, Rasmus, E-mail: mburke@star.sr.bham.ac.uk [Department of Astrophysics/IMAPP, Radboud, University Nijmegen, P.O. Box 9010, NL-6500 GL Nijmegen (Netherlands)] [Department of Astrophysics/IMAPP, Radboud, University Nijmegen, P.O. Box 9010, NL-6500 GL Nijmegen (Netherlands); and others

    2013-04-01

    We present a spectral investigation of X-ray binaries (XBs) in NGC 5128 (Cen A), using six 100 ks Chandra observations taken over two months in 2007. We divide our sample into thermally and non-thermally dominated states based on the behavior of the fitted absorption column N{sub H}, and present the spectral parameters of sources with L{sub x} {approx}> 2 Multiplication-Sign 10{sup 37} erg s{sup -1}. The majority of sources are consistent with being neutron star low-mass X-ray binaries (NS LMXBs) and we identify three transient black hole (BH) LMXB candidates coincident with the dust lane, which is the remnant of a small late-type galaxy. Our results also provide tentative support for the apparent 'gap' in the mass distribution of compact objects between {approx}2-5 M{sub Sun }. We propose that BH LMXBs are preferentially found in the dust lane, and suggest this is because of the younger stellar population. The majority ({approx}70%-80%) of potential Roche lobe filling donors in the Cen A halo are {approx}> 12 Gyr old, while BH LMXBs require donors {approx}> 1 M{sub Sun} to produce the observed peak luminosities. This requirement for more massive donors may also explain recent results that claim a steepening of the X-ray luminosity function with age at L{sub x} {>=} 5 Multiplication-Sign 10{sup 38} erg s{sup -1} for the XB population of early-type galaxies; for older stellar populations, there are fewer stars {approx}> 1 M{sub Sun }, which are required to form the more luminous sources.

  19. RR Pic (1925): A Chandra X-ray View

    E-Print Network [OSTI]

    Y. Pekon; S. Balman

    2008-05-20

    We present the Chandra ACIS-S3 data of the old classical nova RR Pic (1925). The source has a count rate of 0.067+/-0.002 c/s in the 0.3-5.0 keV energy range. We detect the orbital period of the underlying binary system in the X-ray wavelengths. We also find that the neutral Hydrogen column density differs for orbital minimum and orbital maximum spectra with values 0.25(+0.23-0.18)x10^22 cm^-2 and 0.64(+0.13-0.14)x10^22 cm^-2 at 3sigma confidence level. The X-ray spectrum of RR Pic can be represented by a composite model of bremsstrahlung with a photoelectric absorption, two absorption lines centered around 1.1-1.4 keV and 5 Gaussian lines centered at emission lines around 0.3-1.1 keV corresponding to various transitions of S, N, O, C, Ne and Fe . The bremsstrahlung temperature derived from the fits range from 0.99 to 1.60 keV and the unabsorbed X-ray flux is found to be 2.5(+0.4-1.2)x10^-13 erg cm^-2 s^-1 in the 0.3-5.0 keV range with a luminosity of (1.1\\pm0.2)x10^31 erg s^-1 at 600 pc. We also detect excess emission in the spectrum possibly originating from the reverse shock in the ejecta.

  20. Accuracy evaluation of a Compton X-ray spectrometer with bremsstrahlung X-rays generated by a 6 MeV electron bunch

    SciTech Connect (OSTI)

    Kojima, Sadaoki Arikawa, Yasunobu; Zhang, Zhe; Ikenouchi, Takahito; Morace, Alessio; Nagai, Takahiro; Abe, Yuki; Sakata, Shouhei; Inoue, Hiroaki; Utsugi, Masaru; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Fujioka, Shinsuke; Azechi, Hiroshi; Nishimura, Yasuhiko; Togawa, Hiromi; Ozaki, Tetsuo; Kato, Ryukou

    2014-11-15

    A Compton-scattering-based X-ray spectrometer is developed to obtain the energy distribution of fast electrons produced by intense laser and matter interactions. Bremsstrahlung X-rays generated by fast electrons in a material are used to measure fast electrons’ energy distribution in matter. In the Compton X-ray spectrometer, X-rays are converted into recoil electrons by Compton scattering in a converter made from fused silica glass, and a magnet-based electron energy analyzer is used to measure the energy distribution of the electrons that recoil in the direction of the incident X-rays. The spectrum of the incident X-rays is reconstructed from the energy distribution of the recoil electrons. The accuracy of this spectrometer is evaluated using a quasi-monoenergetic 6 MeV electron bunch that emanates from a linear accelerator. An electron bunch is injected into a 1.5 mm thick tungsten plate to produce bremsstrahlung X-rays. The spectrum of these bremsstrahlung X-rays is obtained in the range from 1 to 9 MeV. The energy of the electrons in the bunch is estimated using a Monte Carlo simulation of particle-matter interactions. The result shows that the spectrometer's energy accuracy is ±0.5 MeV for 6.0 MeV electrons.

  1. Astrophysics Research Projects:Astrophysics Research Projects: massive star winds, x-ray emission, theoretical models,massive star winds, x-ray emission, theoretical models,

    E-Print Network [OSTI]

    Cohen, David

    Astrophysics Research Projects:Astrophysics Research Projects: massive star winds, x-ray emission, theoretical models,massive star winds, x-ray emission, theoretical models, spectroscopy, laboratory plasma-drivenhave powerful radiation-driven stellar windsstellar winds.. etaeta CarinaCarina #12;TheThe ChandraChandra X

  2. PHYSICAL PROCESSES SHAPING GAMMA-RAY BURST X-RAY AFTERGLOW LIGHT CURVES: THEORETICAL IMPLICATIONS FROM THE SWIFT X-RAY TELESCOPE OBSERVATIONS

    E-Print Network [OSTI]

    Zhang, Bing

    PHYSICAL PROCESSES SHAPING GAMMA-RAY BURST X-RAY AFTERGLOW LIGHT CURVES: THEORETICAL IMPLICATIONS August 15; accepted 2005 December 19 ABSTRACT With the successful launch of the Swift Gamma-Ray Burst component is consistent with the tail emission of the prompt gamma-ray bursts and/or the X-ray flares

  3. NuSTAR Hard X-ray Survey of the Galactic Center Region I: Hard X-ray Morphology and Spectroscopy of the Diffuse Emission

    E-Print Network [OSTI]

    Mori, Kaya; Krivonos, Roman; Hong, Jaesub; Ponti, Gabriele; Bauer, Franz; Perez, Kerstin; Nynka, Melania; Zhang, Shuo; Tomsick, John A; Alexander, David M; Baganoff, Frederick K; Barret, Didier; Barriere, Nicolas; Boggs, Steven E; Canipe, Alicia M; Christensen, Finn E; Craig, William W; Forster, Karl; Giommi, Paolo; Grefenstette, Brian W; Grindlay, Jonathan E; Harrison, Fiona A; Hornstrup, Allan; Kitaguchi, Takao; Koglin, Jason E; Luu, Vy; Madsen, Kristen K; Mao, Peter H; Miyasaka, Hiromasa; Perri, Matteo; Pivovaroff, Michael J; Puccetti, Simonetta; Rana, Vikram; Stern, Daniel; Westergaard, Niels J; Zhang, William W; Zoglauer, Andreas

    2015-01-01

    We present the first sub-arcminute images of the Galactic Center above 10 keV, obtained with NuSTAR. NuSTAR resolves the hard X-ray source IGR J17456-2901 into non-thermal X-ray filaments, molecular clouds, point sources and a previously unknown central component of hard X-ray emission (CHXE). NuSTAR detects four non-thermal X-ray filaments, extending the detection of their power-law spectra with $\\Gamma\\sim1.3$-$2.3$ up to ~50 keV. A morphological and spectral study of the filaments suggests that their origin may be heterogeneous, where previous studies suggested a common origin in young pulsar wind nebulae (PWNe). NuSTAR detects non-thermal X-ray continuum emission spatially correlated with the 6.4 keV Fe K$\\alpha$ fluorescence line emission associated with two Sgr A molecular clouds: MC1 and the Bridge. Broad-band X-ray spectral analysis with a Monte-Carlo based X-ray reflection model self-consistently determined their intrinsic column density ($\\sim10^{23}$ cm$^{-2}$), primary X-ray spectra (power-laws wi...

  4. Advances in X-Ray Chemical Analysis, Japan, 41 (2010) ISSN 0911-7806 Theoretical Analysis of X-Ray Waveguide Using Fresnel Diffraction

    E-Print Network [OSTI]

    Jun, Kawai

    2010-01-01

    -Ray Waveguide Using Fresnel Diffraction Yusuke MORIKAWA and Jun KAWAI #12;#12;41 145 X Adv. X-Ray. Chem. Anal., Japan 41, pp.145-150 (2010) 606-8501 X Theoretical Analysis of X-Ray Waveguide Using Fresnel Diffraction symmetrical pattern. We regard it as a slit and calculated the Fresnel diffraction. We find

  5. Red Noise in Anomalous X-ray Pulsar Timing Residuals

    E-Print Network [OSTI]

    Anne M. Archibald; Rim Dib; Margaret A. Livingstone; Victoria M. Kaspi

    2007-12-20

    Anomalous X-ray Pulsars (AXPs), thought to be magnetars, exhibit poorly understood deviations from a simple spin-down called "timing noise". AXP timing noise has strong low-frequency components which pose significant challenges for quantification. We describe a procedure for extracting two quantities of interest, the intensity and power spectral index of timing noise. We apply this procedure to timing data from three sources: a monitoring campaign of five AXPs, observations of five young pulsars, and the stable rotator PSR B1937+21.

  6. Growing Cutting-edge X-ray Optics

    ScienceCinema (OSTI)

    Ray Conley

    2013-07-17

    Ever imagined that an Xbox controller could help open a window into a world spanning just one billionth of a meter? Brookhaven Lab's Ray Conley grows cutting-edge optics called multilayer Laue lenses (MLL) one atomic layer at a time to focus high-energy x-rays to within a single nanometer. To achieve this focusing feat, Ray uses a massive, custom-built atomic deposition device, an array of computers, and a trusty Xbox controller. These lenses will be deployed at the Lab's National Synchrotron Light Source II, due to begin shining super-bright light on pressing scientific puzzles in 2015

  7. Supersymmetric Higgs-portal and X-ray lines

    E-Print Network [OSTI]

    Hyun Min Lee; Chan Beom Park; Myeonghun Park

    2015-01-29

    We consider a Dirac singlet fermion as thermal dark matter for explaining the X-ray line in the context of a supersymmetric Higgs-portal model or a generalized Dirac NMSSM. The Dirac singlet fermion gets a mass splitting due to their Yukawa couplings to two Higgs doublets and their superpartners, Higgsinos, after electroweak symmetry breaking. We show that a correct relic density can be obtained from thermal freeze-out, due to the co-annihilation with Higgsinos for the same Yukawa couplings. We discuss the phenomenology of the Higgsinos in this model such as displaced vertices at the LHC.

  8. Kaonic hydrogen X-ray measurement in SIDDHARTA

    E-Print Network [OSTI]

    M. Bazzi; G. Beer; L. Bombelli; A. M. Bragadireanu; M. Cargnelli; G. Corradi; C. Curceanu; A. d'Uffizi; C. Fiorini; T. Frizzi; F. Ghio; C. Guaraldo; R. S. Hayano; M. Iliescu; T. Ishiwatari; M. Iwasaki; P. Kienle; P. Levi Sandri; A. Longoni; V. Lucherini; J. Marton; S. Okada; D. Pietreanu; T. Ponta; A. Rizzo; A. Romero Vidal; A. Scordo; H. Shi; D. L. Sirghi; F. Sirghi; H. Tatsuno; A. Tudorache; V. Tudorache; O. Vazquez Doce; E. Widmann; J. Zmeskal

    2012-01-23

    Kaonic hydrogen atoms provide a unique laboratory to probe the kaon-nucleon strong interaction at the energy threshold, allowing an investigation of the interplay between spontaneous and explicit chiral symmetry breaking in low-energy QCD. The SIDDHARTA Collaboration has measured the $K$-series X rays of kaonic hydrogen atoms at the DA$\\Phi$NE electron-positron collider of Laboratori Nazionali di Frascati, and has determined the most precise values of the strong-interaction induced shift and width of the $1s$ atomic energy level. This result provides vital constraints on the theoretical description of the low-energy $\\bar{K}N$ interaction.

  9. Modeling of X-ray beamlines and devices

    SciTech Connect (OSTI)

    Ice, G.E.

    1996-12-31

    X-ray beamlines on synchrotron sources are similar in size and complexity to beamlines at state-of-the-art neutron sources. The design principles, tools, and optimization strategies for synchrotron beamlines are also similar to those of neutron beamlines. The authors describe existing design tools for modeling synchrotron radiation beamlines and describe how these tools have evolved over the last two decades. The development of increasingly powerful modeling tools has been driven by the escalating cost and sophistication of state-of-the-art beamlines and by a world-wide race to exploit advanced synchrotron radiation sources.

  10. IN SITU SURFACE X-RAY SCATTERING STUDIES OF ELECTROSORPTION

    SciTech Connect (OSTI)

    WANG,J.X.; ADZIC,R.R.; OCKO,B.M.

    1998-07-01

    A short review of the application of surface x-ray scattering techniques to the electrode/electrolyte interfaces is presented. Recent results on metal, halide, and metal-halide adlayers with three specific systems: Bi on Au(100) and Au(110); Br on Au(100) and Ag(100); and the coadsorption of Tl with Br or I on Au(111), are given as an illustration. Factors affecting ordering of pure metal and halide adlayers and the metal-halide surface compounds are discussed in some detail.

  11. Stimulated X-Ray Emission for Spectroscopy | Stanford Synchrotron Radiation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation ofAlbuquerque|SensitiveApril 2,BL4-2StefanLightsource Stimulated X-Ray

  12. Biological Imaging by Soft X-Ray Diffraction Microscopy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room News PublicationsAudits & InspectionsBeryllium andSamplerBiological Imaging by Soft X-Ray

  13. ALS X-Rays Shine a New Light on Catalysis

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefieldSulfateSciTechtail.TheoryTuesday, August 10, 20102016 NewsUsers' Executive Committee ALSALS X-Rays Shine

  14. ALS X-Rays Shine a New Light on Catalysis

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefieldSulfateSciTechtail.TheoryTuesday, August 10, 20102016 NewsUsers' Executive Committee ALSALS X-Rays

  15. ALS X-Rays Shine a New Light on Catalysis

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefieldSulfateSciTechtail.TheoryTuesday, August 10, 20102016 NewsUsers' Executive Committee ALSALS X-RaysALS

  16. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration wouldMass mapSpeeding access| DepartmentPeerFederalPlatinumtake the 2011|PoemandPolarized X-Rays

  17. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration wouldMass mapSpeeding access| DepartmentPeerFederalPlatinumtake thePolarized X-Rays Reveal

  18. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration wouldMass mapSpeeding access| DepartmentPeerFederalPlatinumtake thePolarized X-Rays

  19. X-Ray Diffraction (XRD) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmental Jump to:EAand Dalton Jump to:Wylie, Texas: Energy ResourcessourceX-Ray Diffraction

  20. Category:X-Ray Diffraction (XRD) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmentalBowerbank,CammackFLIR Jump to:RAPID RoadmapInformation UtilityWindX-Ray

  1. Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking With WIPPfinalUnexpected Angular Dependence of X-Ray Magnetic Linear

  2. Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking With WIPPfinalUnexpected Angular Dependence of X-Ray Magnetic

  3. Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking With WIPPfinalUnexpected Angular Dependence of X-Ray

  4. Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking With WIPPfinalUnexpected Angular Dependence of X-RayUnexpected Angular

  5. X-Ray Diffraction Microscopy of Magnetic Structures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWind Power >X-Ray Diffraction

  6. X-Ray Diffraction Microscopy of Magnetic Structures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWind Power >X-Ray

  7. X-ray Microscopy and Imaging (XSD-XMI)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWindX-Ray ImagingInImaging

  8. XRMS: X-Ray Spectroscopy of Magnetic Solids

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single Micropulse lidarXRMS: X-Ray

  9. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformationJesseworkSURVEYI/OPerformancePi Day Pi Day Pi DayPlasmaandAboutPolarized X-Rays

  10. X-ray Properties of Young Stellar Objects in OMC-2 and OMC-3 from the Chandra X-ray Observatory

    E-Print Network [OSTI]

    M. Tsujimoto; K. Koyama; Y. Tsuboi; M. Goto; N. Kobayashi

    2001-10-12

    We report X-ray results of the Chandra observation of Orion Molecular Cloud 2 and 3. A deep exposure of \\sim 100 ksec detects \\sim 400 X-ray sources in the field of view of the ACIS array, providing one of the largest X-ray catalogs in a star forming region. Coherent studies of the source detection, time variability, and energy spectra are performed. We classify the X-ray sources into class I, class II, and class III+MS based on the J, H, and K-band colors of their near infrared counterparts and discuss the X-ray properties (temperature, absorption, and time variability) along these evolutionary phases.

  11. Synchrotron Radiation {mu}-X Ray Fluorescence on Multicellular Tumor Spheroids

    SciTech Connect (OSTI)

    Burattini, E.; Cinque, G.; Bellisola, G.; Fracasso, G.; Colombatti, M.; Monti, F.

    2003-01-24

    Synchrotron Radiation micro X-Ray Fluorescence (SR {mu}-XRF) was applied for the first time to map the trace element content on Multicellular Tumor Spheroids (MTS), i.e. human cell clusters used as an in vitro model for testing micrometastases responses to antitumoral drugs. In particular, immunotoxin molecules composed of a carrier protein (Transferrin) bound to a powerful cytotoxin (Ricin A), were here considered as representatives of a class of therapheutic macromolecules used in cancer theraphy. Spheroids included in polyacrylamide gel and placed inside quartz capillaries were studied at the ESRF ID22 beamline using a 15 keV monochromatic photon microbeam. Elemental maps (of Fe, Cu, Zn and Pb) on four groups of spheroids grown under different conditions were studied: untreated, treated only with the carrier molecule or with the toxin alone, and with the complete immunotoxin molecule (carrier+toxin). The results indicate that the distribution of Zn and, to some extent, Cu in the spheroid cells is homogeneous and independent of the treatment type. Total Reflection X-Ray Fluorescence (TR-XRF) was also applied to quantify the average trace element content in the spheroids. Future developments of the technique are finally outlined on the basis of these preliminary results.

  12. RESIK observations of He-like Ar X-ray line emission in solar flares

    E-Print Network [OSTI]

    J. Sylwester; B. Sylwester; K. J. H. Phillips

    2008-06-09

    The Ar XVII X-ray line group principally due to transitions 1s2 - 1s2l (l=s, p) near 4 Anstroms was observed in numerous flares by the RESIK bent crystal spectrometer aboard CORONAS-F between 2001 and 2003. The three line features include the Ar XVII w (resonance line), a blend of x and y (intercombination lines), and z (forbidden line), all of which are blended with Ar XVI dielectronic satellites. The ratio G, equal to [I(x+y) + I(z)]/I(w), varies with electron temperature Te mostly because of unresolved dielectronic satellites. With temperatures estimated from GOES X-ray emission, the observed G ratios agree fairly well with those calculated from CHIANTI and other data. With a two-component emission measure, better agreement is achieved. Some S XV and S XVI lines blend with the Ar lines, the effect of which occurs at temperatures greater than 8MK, allowing the S/Ar abundance ratio to be determined. This is found to agree with coronal values. A nonthermal contribution is indicated for some spectra in the repeating-pulse flare of 2003 February 6.

  13. Crystallization and X-ray structure of full-length recombinant human butyrylcholinesterase

    SciTech Connect (OSTI)

    Ngamelue, Michelle N.; Homma, Kohei [Pathology and Microbiology Department, University of Nebraska Medical Center, 986495 Nebraska Medical Center, Omaha, NE 68198-6495 (United States); Lockridge, Oksana [Eppley Cancer Institute, University of Nebraska Medical Center, 986805 Nebraska Medical Center, Omaha, NE 68198-6805 (United States); Asojo, Oluwatoyin A., E-mail: oasojo@unmc.edu [Pathology and Microbiology Department, University of Nebraska Medical Center, 986495 Nebraska Medical Center, Omaha, NE 68198-6495 (United States)

    2007-09-01

    The first crystals and the 2.8 Å X-ray structure of full-length recombinant human butyrylcholinesterase are reported. Human butyrylcholinesterase (BChE) has been shown to function as an endogenous scavenger of diverse poisons. BChE is a 340 kDa tetrameric glycoprotein that is present in human serum at a concentration of 5 mg l{sup ?1}. The well documented therapeutic effects of BChE on cocaine toxicity and organophosphorus agent poisoning has increased the need for effective methods of producing recombinant therapeutic BChE. In order to be therapeutically useful, BChE must have a long circulatory residence time or associate as tetramers. Full-length recombinant BChE produced in Chinese hamster ovary (CHO) cells or human embryonic kidney cells has been shown to associate as monomers, with a shorter circulatory residence time than the naturally occurring tetrameric serum protein. Based on the preceding observation as well as the need to develop novel methodologies to facilitate the mass production of therapeutic recombinant BChE, studies have been initiated to determine the structural basis of tetramer formation. Towards these ends, full-length monomeric recombinant BChE has been crystallized for the first time. A 2.8 Å X-ray structure was solved in space group P42{sub 1}2, with unit-cell parameters a = b = 156, c = 146 Å.

  14. Characterization of the Electronic Structure of Silicon Nanoparticles Using X-ray Absorption and Emission

    SciTech Connect (OSTI)

    Vaverka, A M

    2008-07-15

    Resolving open questions regarding transport in nanostructures can have a huge impact on a broad range of future technologies such as light harvesting for energy. Silicon has potential to be used in many of these applications. Understanding how the band edges of nanostructures move as a function of size, surface termination and assembly is of fundamental importance in understanding the transport properties of these materials. In this thesis work I have investigated the change in the electronic structure of silicon nanoparticle assemblies as the surface termination is changed. Nanoparticles are synthesized using a thermal evaporation technique and sizes are determined using atomic force microscopy (AFM). By passivating the particles with molecules containing alcohol groups we are able to modify the size dependent band edge shifts. Both the valence and conduction bands are measured using synchrotron based x-ray absorption spectroscopy (XAS) and soft x-ray fluorescence (SXF) techniques. Particles synthesized via recrystallization of amorphous silicon/SiO{sub 2} multilayers of thicknesses below 10 nm are also investigated using the synchrotron techniques. These samples also show quantum confinement effects but the electronic structure is different from those synthesized via evaporation methods. The total bandgap is determined for all samples measured. The origins of these differences in the electronic structures are discussed.

  15. The Phoenix Deep Survey: the radio properties of the hard X-ray selected sample

    E-Print Network [OSTI]

    A. Georgakakis; A. M. Hopkins; J. Afonso; M. Sullivan; B. Mobasher; L. E. Cram

    2004-07-05

    The radio properties of hard (2-8keV) X-ray selected sources are explored by combining a single 50ks XMM-Newton pointing with the ultra-deep and homogeneous Phoenix radio (1.4GHz) survey (Hopkins et al. 2003). A total of 43 sources are detected above the X-ray flux limit f_X(2-8keV)=7.7e-15cgs with 14 of them exhibiting radio emission above ~40muJy (3sigma). The X-ray/radio matched population lies in the borderline between radio loud and quiet AGNs and comprises sources with both soft and hard X-ray spectral properties suggesting both obscured and unobscured systems. The spectroscopically identified sub-sample (total of 6 X-ray/radio matches) comprises narrow emission line AGNs (4) with hard X-ray spectral properties and broad line sources (2) with soft X-ray spectra. We find evidence that the fraction of X-ray/radio matches increases from ~20% for sources with rest-frame column density N_H1e22cm^-2 their combined spectrum exhibits a soft X-ray component that may be associated with star-formation activity, although other possibilities cannot be excluded. We also find that radio emitting AGNs make up about 13-20% of the hard-band X-ray background depending on the adopted normalisation.

  16. A Chandra Deep X-ray Exposure on the Galactic Plane and Near Infrared Identification

    E-Print Network [OSTI]

    K. Ebisawa; A. Paizis; T. J. -L. Couvoisier; P. Dubath; M. Tsujimoto; K. Hamaguchi; V. Beckmann; A. Bamba; A. Senda; M. Ueno; H. Kaneda; Y. Maeda; G. Sato; S. Yamauchi; R. Cutri; E. Nishihara

    2004-07-09

    Using the Chandra ACIS-I instruments, we have carried out a deep X-ray observation on the Galactic plane region at (l,b) ~ (28.5, 0.0), where no discrete X-ray sources have been known previously. We have detected, as well as strong diffuse emission, 274 new point X-ray sources (4 sigma confidence) within two partially overlapping fields (~250 arcmin^2 in total) down to the flux limit ~3 x 10^{-15} $ erg s^{-1} cm^{-2} (2 -- 10 keV) and ~ 7 x 10^{-16} erg s^{-1} cm^{-2} (0.5 -- 2 keV). We clearly resolved point sources and the Galactic diffuse emission, and found that ~ 90 % of the flux observed in our field of view originates from diffuse emission. Many point sources are detected either in the soft X-ray band (below 2 keV) or in the hard band (above 2 keV), and only a small number of sources are detected in both energy bands. On the other hand, most soft X-ray sources are considered to be nearby X-ray active stars. We have carried out a follow-up near-infrared (NIR) observation using SOFI at ESO/NTT. Most of the soft X-ray sources were identified, whereas only a small number of hard X-ray sources had counterparts in NIR. Using both X-ray and NIR information, we can efficiently classify the point X-ray sources detected in the Galactic plane. We conclude that most of the hard X-ray sources are background Active Galactic Nuclei seen through the Milky Way, whereas majority of the soft X-ray sources are nearby X-ray active stars.

  17. Thermal Evaporation of Gas from X-ray Clusters

    E-Print Network [OSTI]

    Abraham Loeb

    2006-09-18

    A fraction of the thermal protons in the outer envelope of an X-ray cluster have velocities that exceed the local escape speed from the cluster gravitational potential. The Coulomb mean-free-path of these protons is larger than the virial radius of the cluster at temperatures >2.5 keV. The resulting leakage of suprathermal particles generates a collisionless shock in neighboring voids and fills them with heat and magnetic fields. The momentum flux of suprathermal particles cannot be confined by magnetic tension at the typical field strength in the periphery of cluster halos (heat is deposited into the gas by cluster mergers, active galactic nuclei or supernovae. Thermal evaporation is not included in existing cosmological simulations since they are based on the fluid approximation. Measurements of the baryon mass fraction in the outer envelopes of hot clusters (through their Sunyaev-Zel'dovich effect or X-ray emission) can be used to empirically constrain their evaporation rate.

  18. NASA's Future Missions in X-ray Astronomy

    E-Print Network [OSTI]

    Nicholas E. White

    2002-02-19

    The NASA program in X-ray astronomy has two long term goals: 1) to achieve sufficient angular resolution to image the event horizon of a black hole (0.1 micro arc sec) and 2) to achieve sufficient collecting area (50-150 sq m) and angular resolution (0.1-1.0 arc sec) to observe in detail the first black holes and galaxies at high redshift. These ambitous goals can be used to map out a series of missions and a technology program. The next major mission will be Constellation-X which will be dedicated to high resolution X-ray spectroscopy for launch in ~2010. This mission is a critical step in the roadmap to achieve these goals. Following Constellation-X NASA is considering two very ambitious vision missions: MAXIM and Generation-X that will achieve the ultimate capabilities. The modest missions Astro-E2 and Swift address more focussed science goals on a rapid development cycle and provide important pathfinders to the larger missions.

  19. Wide band focusing x-ray spectrograph with spatial resolution

    SciTech Connect (OSTI)

    Pikuz, S. A.; Douglass, J. D.; Shelkovenko, T. A.; Sinars, D. B.; Hammer, D. A.

    2008-01-15

    A new, wide spectral bandwidth x-ray spectrograph, the wide-bandwidth focusing spectrograph with spatial resolution (WB-FSSR), based on spherically bent mica crystals, is described. The wide bandwidth is achieved by combining three crystals to form a large aperture dispersive element. Since the WB-FSSR covers a wide spectral band, it is very convenient for application as a routine diagnostic tool in experiments in which the desired spectral coverage is different from one test to the next. The WB-FSSR has been tested in imploding wire-array experiments on a 1 MA pulsed power machine, and x-ray spectra were recorded in the 1-20 A spectral band using different orders of mica crystal reflection. Using a two mirror-symmetrically placed WB-FSSR configuration, it was also possible to distinguish between a real spectral shift and a shift of recorded spectral lines caused by the spatial distribution of the radiating plasma. A spectral resolution of about 2000 was demonstrated and a spatial resolution of {approx}100 {mu}m was achieved in the spectral band of 5-10 A in second order of mica reflection. A simple method of numerical analysis of spectrograph capability is proposed.

  20. Repeated X-ray Flaring Activity in Sagittarius A*

    E-Print Network [OSTI]

    Guillaume Belanger; Andrea Goldwurm; Fulvio Melia; Farah Yusef-Zadeh; Philippe Ferrando; Delphine Porquet; Nicolas Grosso; Robert Warwick

    2005-08-19

    Investigating the spectral and temporal characteristics of the X-rays coming from Sagittarius A* (Sgr A*) is essential to our development of a more complete understanding of the emission mechanisms in this supermassive black hole located at the center of our Galaxy. Several X-ray flares with varying durations and spectral features have already been observed from this object. Here we present the results of two long XMM-Newton observations of the Galactic nucleus carried out in 2004, for a total exposure time of nearly 500 ks. During these observations we detected two flares from Sgr A* with peak 2-10 keV luminosities about 40 times (L ~ 9x10^34 erg s?1) above the quiescent luminosity: one on 2004 March 31 and another on 2004 August 31. The first flare lasted about 2.5 ks and the second about 5 ks. The combined fit on the Epic spectra yield photon indeces of about 1.5 and 1.9 for the first and second flare respectively. This hard photon index strongly suggests the presence of an important population of non-thermal electrons during the event and supports the view that the majority of flaring events tend to be hard and not very luminous.

  1. X-ray spectral variability of type 2 Seyfert galaxies

    E-Print Network [OSTI]

    Hernández-García, L; González-Martín, O; Márquez, I

    2015-01-01

    Variability across the electromagnetic spectrum is a property of AGN that can help constraining the physical properties of these galaxies. This is the third of a serie of papers with the aim of studying the X-ray variability of different families of AGN. The main purpose of this work is to investigate the variability pattern in a sample of optically selected type 2 Seyfert galaxies. We use the 26 Seyferts in the Veron-Cetty and Veron catalogue with data available from Chandra and/or XMM-Newton public archives at different epochs, with timescales ranging from a few hours to years. All the spectra of the same source are simultaneously fitted and we let different parameters to vary in the model. Whenever possible, short-term variations and/or long-term UV flux variations are studied. We divide the sample in Compton-thick, Compton-thin, and changing-look candidates. Short-term variability at X-rays is not found. From the 25 analyzed sources, 11 show long-term variations; eight (out of 11) are Compton-thin, one (o...

  2. X-ray Spectral Properties of Gamma-Ray Bursts

    E-Print Network [OSTI]

    T. E. Strohmayer; E. E. Fenimore; T. Murakami; A. Yoshida

    1997-12-18

    We summarize the spectral characteristics of a sample of 22 bright gamma-ray bursts detected with the gamma-ray burst sensors aboard the satellite Ginga. This instrument employed a proportional and scintillation counter to provide sensitivity to photons in the 2 - 400 keV range, providing a unique opportunity to characterize the largely unexplored X-ray properties of gamma-ray bursts. The photon spectra of the Ginga bursts are well described by a low energy slope, a bend energy, and a high energy slope. In the energy range where they can be compared, this result is consistent with burst spectral analyses obtained from the BATSE experiment aboard the Compton Observatory. However, below 20 keV we find evidence for a positive spectral number index in approximately 40% of our burst sample, with some evidence for a strong rolloff at lower energies in a few events. There is a correlation (Pearson's r = -0.62) between the low energy slope and the bend energy. We find that the distribution of spectral bend energies extends below 10 keV. The observed ratio of energy emitted in the X-rays relative to the gamma-rays can be much larger than a few percent and, in fact, is sometimes larger than unity. The average for our sample is 24%.

  3. The ASTRO-H X-ray Astronomy Satellite

    E-Print Network [OSTI]

    Takahashi, Tadayuki; Kelley, Richard; Aharonian, Felix; Akamatsu, Hiroki; Akimoto, Fumie; Allen, Steve; Anabuki, Naohisa; Angelini, Lorella; Arnaud, Keith; Asai, Makoto; Audard, Marc; Awaki, Hisamitsu; Azzarello, Philipp; Baluta, Chris; Bamba, Aya; Bando, Nobutaka; Bautz, Marshall; Bialas, Thomas; Blandford, Roger; Boyce, Kevin; Brenneman, Laura; Brown, Greg; Cackett, Edward; Canavan, Edgar; Chernyakova, Maria; Chiao, Meng; Coppi, Paolo; Costantini, Elisa; de Plaa, Jelle; Herder, Jan-Willem den; DiPirro, Michael; Done, Chris; Dotani, Tadayasu; Doty, John; Ebisawa, Ken; Eckart, Megan; Enoto, Teruaki; Ezoe, Yuichiro; Fabian, Andrew; Ferrigno, Carlo; Foster, Adam; Fujimoto, Ryuichi; Fukazawa, Yasushi; Funk, Stefan; Furuzawa, Akihiro; Galeazzi, Massimiliano; Gallo, Luigi; Gandhi, Poshak; Gilmore, Kirk; Guainazzi, Matteo; Haas, Daniel; Haba, Yoshito; Hamaguchi, Kenji; Harayama, Atsushi; Hatsukade, Isamu; Hayashi, Takayuki; Hayashi, Katsuhiro; Hayashida, Kiyoshi; Hiraga, Junko; Hirose, Kazuyuki; Hornschemeier, Ann; Hoshino, Akio; Hughes, John; Hwang, Una; Iizuka, Ryo; Inoue, Yoshiyuki; Ishibashi, Kazunori; Ishida, Manabu; Ishikawa, Kumi; Ishimura, Kosei; Ishisaki, Yoshitaka; Ito, Masayuki; Iwata, Naoko; Iyomoto, Naoko; Jewell, Chris; Kaastra, Jelle; Kallman, Timothy; Kamae, Tuneyoshi; Kataoka, Jun; Katsuda, Satoru; Katsuta, Junichiro; Kawaharada, Madoka; Kawai, Nobuyuki; Kawano, Taro; Kawasaki, Shigeo; Khangulyan, Dmitry; Kilbourne, Caroline; Kimball, Mark; Kimura, Masashi; Kitamoto, Shunji; Kitayama, Tetsu; Kohmura, Takayoshi; Kokubun, Motohide; Konami, Saori; Kosaka, Tatsuro; Koujelev, Alex; Koyama, Katsuji; Krimm, Hans; Kubota, Aya; Kunieda, Hideyo; LaMassa, Stephanie; Laurent, Philippe; Lebrun, Franccois; Leutenegger, Maurice; Limousin, Olivier; Loewenstein, Michael; Long, Knox; Lumb, David; Madejski, Grzegorz; Maeda, Yoshitomo; Makishima, Kazuo; Markevitch, Maxim; Masters, Candace; Matsumoto, Hironori; Matsushita, Kyoko; McCammon, Dan; Mcguinness, Daniel; McNamara, Brian; Miko, Joseph; Miller, Jon; Miller, Eric; Mineshige, Shin; Minesugi, Kenji; Mitsuishi, Ikuyuki; Miyazawa, Takuya; Mizuno, Tsunefumi; Mori, Koji; Mori, Hideyuki; Moroso, Franco; Muench, Theodore; Mukai, Koji; Murakami, Hiroshi; Murakami, Toshio; Mushotzky, Richard; Nagano, Housei; Nagino, Ryo; Nakagawa, Takao; Nakajima, Hiroshi; Nakamori, Takeshi; Nakashima, Shinya; Nakazawa, Kazuhiro; Namba, Yoshiharu; Natsukari, Chikara; Nishioka, Yusuke; Nobukawa, Masayoshi; Noda, Hirofumi; Nomachi, Masaharu; Dell, Steve O'; Odaka, Hirokazu; Ogawa, Hiroyuki; Ogawa, Mina; Ogi, Keiji; Ohashi, Takaya; Ohno, Masanori; Ohta, Masayuki; Okajima, Takashi; Okamoto, Atsushi; Okazaki, Tsuyoshi; Ota, Naomi; Ozaki, Masanobu; Paerels, Frits; Paltani, St'ephane; Parmar, Arvind; Petre, Robert; Pinto, Ciro; Pohl, Martin; Pontius, James; Porter, F Scott; Pottschmidt, Katja; Ramsey, Brian; Reis, Rubens; Reynolds, Christopher; Ricci, Claudio; Russell, Helen; Safi-Harb, Samar; Saito, Shinya; Sakai, Shin-ichiro; Sameshima, Hiroaki; Sato, Goro; Sato, Yoichi; Sato, Kosuke; Sato, Rie; Sawada, Makoto; Serlemitsos, Peter; Seta, Hiromi; Shibano, Yasuko; Shida, Maki; Shimada, Takanobu; Shinozaki, Keisuke; Shirron, Peter; Simionescu, Aurora; Simmons, Cynthia; Smith, Randall; Sneiderman, Gary; Soong, Yang; Stawarz, Lukasz; Sugawara, Yasuharu; Sugita, Hiroyuki; Sugita, Satoshi; Szymkowiak, Andrew; Tajima, Hiroyasu; Takahashi, Hiromitsu; Takahashi, Hiroaki; Takeda, Shin-ichiro; Takei, Yoh; Tamagawa, Toru; Tamura, Takayuki; Tamura, Keisuke; Tanaka, Takaaki; Tanaka, Yasuo; Tanaka, Yasuyuki; Tashiro, Makoto; Tawara, Yuzuru; Terada, Yukikatsu; Terashima, Yuichi; Tombesi, Francesco; Tomida, Hiroshi; Tsuboi, Yohko; Tsujimoto, Masahiro; Tsunemi, Hiroshi; Tsuru, Takeshi; Uchida, Hiroyuki; Uchiyama, Yasunobu; Uchiyama, Hideki; Ueda, Yoshihiro; Ueda, Shutaro; Ueno, Shiro; Uno, Shinichiro; Urry, Meg; Ursino, Eugenio; de Vries, Cor; Wada, Atsushi; Watanabe, Shin; Watanabe, Tomomi; Werner, Norbert; White, Nicholas; Wilkins, Dan; Yamada, Takahiro; Yamada, Shinya; Yamaguchi, Hiroya; Yamaoka, Kazutaka; Yamasaki, Noriko; Yamauchi, Makoto; Yamauchi, Shigeo; Yaqoob, Tahir; Yatsu, Yoichi; Yonetoku, Daisuke; Yoshida, Atsumasa; Yuasa, Takayuki; Zhuravleva, Irina; Zoghbi, Abderahmen; ZuHone, John

    2014-01-01

    The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions developed by the Institute of Space and Astronautical Science (ISAS), with a planned launch in 2015. The ASTRO-H mission is equipped with a suite of sensitive instruments with the highest energy resolution ever achieved at E > 3 keV and a wide energy range spanning four decades in energy from soft X-rays to gamma-rays. The simultaneous broad band pass, coupled with the high spectral resolution of Delta E < 7 eV of the micro-calorimeter, will enable a wide variety of important science themes to be pursued. ASTRO-H is expected to provide breakthrough results in scientific areas as diverse as the large-scale structure of the Universe and its evolution, the behavior of matter in the gravitational strong field regime, the physical conditions in sites of cosmic-ray acceleration, and the distribution of dark matter in galaxy clusters at different redshifts.

  4. An HST Search for Supernovae Accompanying X-ray Flashes

    E-Print Network [OSTI]

    A. M. Soderberg; S. R. Kulkarni; D. B. Fox; E. Berger; P. A. Price; S. B. Cenko; D. A. Howell; A. Gal-Yam; D. C. Leonard; D. A. Frail; D. Moon; R. A. Chevalier; M. Hamuy; K. C. Hurley; D. Kelson; K. Koviak; W. Krzeminski; P. Kumar; A. MacFadyen; P. J. McCarthy; H. S. Park; B. A. Peterson; M. M. Phillips; M. Rauch; M. Roth; B. P. Schmidt; S. Shectman

    2005-02-25

    We present the results from an Hubble Space Telescope/ACS search for supernovae associated with X-ray flashes 020903, 040701, 040812 and 040916. We find strong evidence that XRF 020903 (z=0.25) was associated with a SN 1998bw-like supernova and confirm this using optical spectroscopy at t ~ 25 days. We find no evidence, however, for SN 1998bw-like supernovae associated with the other three events. In the case of XRF 040701 (z=0.21), we rule out even a faint supernova similar to SN 2002ap, using template light-curves for several local Type Ic supernovae. For the two cases in which the redshift is not known, XRFs 040812 and 040916, we derive robust redshift limits assuming they were accompanied by supernovae similar to SN 1998bw and compare these limits with photometric redshift constraints provided by their host galaxies. We supplement this analysis with results for three additional events (XRFs 011030, 020427 and 030723) and discuss the observed diversity of supernovae associated with X-ray flashes and gamma-ray bursts. We conclude that XRF-SNe exist, but can be significantly fainter than SN 1998bw, possibly consistent with the observed spread in local Type Ibc supernovae.

  5. Chandra Multiwavelength Project X-ray Point Source Number Counts and the Cosmic X-ray Background

    E-Print Network [OSTI]

    Minsun Kim; Belinda J. Wilkes; Dong-Woo Kim; Paul J. Green; Wayne A. Barkhouse; Myung Gyoon Lee; John D. Silverman; Harvey D. Tananbaum

    2006-11-28

    We present the Chandra Multiwavelength Project (ChaMP) X-ray point source number counts and the cosmic X-ray background (CXRB) flux densities in multiple energy bands. From the ChaMP X-ray point source catalog, ~5,500 sources are selected covering 9.6 deg^2 in sky area. To quantitatively characterize the sensitivity and completeness of the ChaMP sample, we perform extensive simulations. We also include the ChaMP+CDFs (Chandra Deep Fields) number counts to cover large flux ranges from 2x10^{-17} to 2.4x10^{-12} (0.5-2 keV) and from 2x10^{-16} to 7.1x10^{-12} (2-8 keV) erg/cm^2/sec. The ChaMP and the ChaMP+CDFs differential number counts are well fitted with a broken power law. The best fit faint and bright power indices are 1.49^{+0.02}_{-0.02} and 2.36^{+0.05}_{-0.05} (0.5-2 keV), and 1.58^{+0.01}_{-0.01} and 2.59^{+0.06}_{-0.05} (2-8 keV), respectively. We detect breaks in the differential number counts and they appear at different fluxes in different energy bands. Assuming a single power law model for a source spectrum, we find that the same population(s) of soft X-ray sources causes the break in the differential number counts for all energy bands. We measure the resolved CXRB flux densities from the ChaMP and the ChaMP+CDFs number counts with and without bright target sources. Adding the known unresolved CXRB to the ChaMP+CDF resolved CXRB, we also estimate total CXRB flux densities. The fractions of the resolved CXRB without target sources are 78^{+1}_{-1}% and 81^{+2}_{-2}% in the 0.5-2 keV and 2-8 keV bands, respectively, somewhat lower, though generally consistent with earlier numbers since their large errors. These fractions increase by ~1% when target sources are included.

  6. Dimensionality and noise in energy selective x-ray imaging

    SciTech Connect (OSTI)

    Alvarez, Robert E.

    2013-11-15

    Purpose: To develop and test a method to quantify the effect of dimensionality on the noise in energy selective x-ray imaging.Methods: The Cramèr-Rao lower bound (CRLB), a universal lower limit of the covariance of any unbiased estimator, is used to quantify the noise. It is shown that increasing dimensionality always increases, or at best leaves the same, the variance. An analytic formula for the increase in variance in an energy selective x-ray system is derived. The formula is used to gain insight into the dependence of the increase in variance on the properties of the additional basis functions, the measurement noise covariance, and the source spectrum. The formula is also used with computer simulations to quantify the dependence of the additional variance on these factors. Simulated images of an object with three materials are used to demonstrate the trade-off of increased information with dimensionality and noise. The images are computed from energy selective data with a maximum likelihood estimator.Results: The increase in variance depends most importantly on the dimension and on the properties of the additional basis functions. With the attenuation coefficients of cortical bone, soft tissue, and adipose tissue as the basis functions, the increase in variance of the bone component from two to three dimensions is 1.4 × 10{sup 3}. With the soft tissue component, it is 2.7 × 10{sup 4}. If the attenuation coefficient of a high atomic number contrast agent is used as the third basis function, there is only a slight increase in the variance from two to three basis functions, 1.03 and 7.4 for the bone and soft tissue components, respectively. The changes in spectrum shape with beam hardening also have a substantial effect. They increase the variance by a factor of approximately 200 for the bone component and 220 for the soft tissue component as the soft tissue object thickness increases from 1 to 30 cm. Decreasing the energy resolution of the detectors increases the variance of the bone component markedly with three dimension processing, approximately a factor of 25 as the resolution decreases from 100 to 3 bins. The increase with two dimension processing for adipose tissue is a factor of two and with the contrast agent as the third material for two or three dimensions is also a factor of two for both components. The simulated images show that a maximum likelihood estimator can be used to process energy selective x-ray data to produce images with noise close to the CRLB.Conclusions: The method presented can be used to compute the effects of the object attenuation coefficients and the x-ray system properties on the relationship of dimensionality and noise in energy selective x-ray imaging systems.

  7. X-ray Spectral Measurements of the Most Massive Stars: Stellar Wind Mass-Loss Rates and Shock Physics

    E-Print Network [OSTI]

    Cohen, David

    X-ray Spectral Measurements of the Most Massive Stars: Stellar Wind Mass-Loss Rates and Shock, and their winds (the site of X-ray production). From the basic question of how the X-rays are produced, I have branched out to questions of wind structure and wind mass-loss rates that the X-ray observations can

  8. SOLAR FLARE ELEMENT ABUNDANCES FROM THE SOLAR ASSEMBLY FOR X-RAYS (SAX) ON Brian R. Dennis1

    E-Print Network [OSTI]

    Nittler, Larry R.

    SOLAR FLARE ELEMENT ABUNDANCES FROM THE SOLAR ASSEMBLY FOR X-RAYS (SAX) ON MESSENGER Brian R been analyzed for 526 large flares detected with the Solar Assembly for X-rays (SAX) on the Mercury ­ Sun: flares ­ Sun: X-rays, gamma-rays 1. INTRODUCTION The Solar Assembly for X-rays (SAX) is part

  9. Accretion Disk Boundary Layers Around Neutron Stars: X-ray Production in Low-Mass X-ray Binaries

    E-Print Network [OSTI]

    Robert Popham; Rashid Sunyaev

    2000-04-03

    We present solutions for the structure of the boundary layer where the accretion disk meets the neutron star, which is expected to be the dominant source of high-energy radiation in low-mass X-ray binaries which contain weakly magnetized accreting neutron stars. We find that the main portion of the boundary layer gas is hot (> ~10^8 K), low in density, radially and vertically extended, and optically thick to scattering but optically thin to absorption. It will produce large X-ray luminosity by Comptonization. Energy is transported inward by viscosity, concentrating the energy dissipation in the dense, optically thick zone close to the stellar surface. We explore the dependence of the boundary layer structure on the mass accretion rate, the rotation rate of the star, the alpha viscosity parameter and the viscosity prescription. Radiation pressure is the dominant source of pressure in the boundary layer; the flux is close to the Eddington limiting flux even for luminosities well below (~0.01 times) L(Edd). At luminosities near L(Edd), the boundary layer expands radially, and has a radial extent larger than one stellar radius. Based on the temperatures and optical depths which characterize the boundary layer, we expect that Comptonization will produce a power-law spectrum at low source luminosities. At high luminosities, a Planckian spectrum will be produced in the dense region where most of the energy is released, and modified by Comptonization as the radiation propagates outward.

  10. THREE NEW GALACTIC CENTER X-RAY SOURCES IDENTIFIED WITH NEAR-INFRARED SPECTROSCOPY

    SciTech Connect (OSTI)

    DeWitt, Curtis; Bandyopadhyay, Reba M.; Eikenberry, Stephen S.; Sarajedini, Ata; Sellgren, Kris; Blum, Robert; Olsen, Knut; Bauer, Franz E.

    2013-11-01

    We have conducted a near-infrared spectroscopic survey of 47 candidate counterparts to X-ray sources discovered by the Chandra X-Ray Observatory near the Galactic center (GC). Though a significant number of these astrometric matches are likely to be spurious, we sought out spectral characteristics of active stars and interacting binaries, such as hot, massive spectral types or emission lines, in order to corroborate the X-ray activity and certify the authenticity of the match. We present three new spectroscopic identifications, including a Be high-mass X-ray binary (HMXB) or a ? Cassiopeiae (Cas) system, a symbiotic X-ray binary, and an O-type star of unknown luminosity class. The Be HMXB/? Cas system and the symbiotic X-ray binary are the first of their classes to be spectroscopically identified in the GC region.

  11. DISCOVERY OF X-RAY PULSATIONS FROM THE NEXT GEMINGA, PSR J1836+5925

    SciTech Connect (OSTI)

    Lin, L. C. C.; Kong, A. K. H. [Institute of Astronomy, National Tsing-Hua University, Hsinchu 30013, Taiwan (China); Hui, C. Y. [Department of Astronomy and Space Science, Chungnam National University, Daejeon (Korea, Republic of); Li, K. T. [Department of Biological Science and Technology, China Medical University, Taichung 40402, Taiwan (China); Takata, J. [Department of Physics, University of Hong Kong, Pokfulam Road, Hong Kong (China); Hu, C. P.; Chou, Y. [Graduate Institute of Astronomy, National Central University, Jhongli 32001, Taiwan (China); Yen, D. C. C., E-mail: cyhui@cnu.ac.kr [Department of Mathematics, Fu Jen Catholic University, New Taipei City 24205, Taiwan (China)

    2014-09-20

    We report recent XMM-Newton investigations of PSR J1836+5925, the ''next Geminga'', which determined an X-ray pulsation of ?173.3 ms. Its X-ray periodicity is consistent with the ?-ray ephemeris at the same epoch. The X-ray folded light curve has a sinusoidal structure that is different from the double-peaked ?-ray pulse profile. We have also analyzed the X-ray phase-averaged spectra which shows that the X-ray emission from PSR J1836+5925 is thermal dominant. This suggests that the X-ray pulsation mainly originates from the modulated hot spot on the stellar surface.

  12. The behavior of subluminous X-ray transients near the Galactic center as observed using the X-ray telescope aboard Swift

    E-Print Network [OSTI]

    N. Degenaar; R. Wijnands

    2009-01-21

    In this paper we report on the spectral analysis of seven X-ray transients, which were found to be active during a monitoring campaign of the Galactic center carried out in 2006 and 2007 using the X-ray telescope aboard the Swift satellite. This campaign detected new outbursts of five known X-ray transients and discovered two new systems. Their 2-10 keV peak luminosities range from 1E34 to 6E36 erg/s. Two of the sources discussed in this paper are confirmed neutron star systems (AX J1745.6-2901 and GRS 1741-2853), while the five others have an unknown nature. We discuss the characteristics of the observed outbursts and the duty cycles of the various systems. Several of the detected transients seem to undergo enhanced X-ray activity with levels intermediate between quiescence and full outburst. We discuss the possibility that the subluminous appearance of the eclipsing X-ray burster AX J1745.6-2901 is due to line-of-sight effects. We detected two type-I X-ray bursts with a duration of 50-60 seconds from AX J1745.6-2901, which we discuss in view of the bursting behavior of low-luminosity X-ray transients. Assuming that we are dealing with accreting neutron stars and black holes, we estimate the time-average accretion rate, Mdot, of the transients, which is an important input parameter for binary evolution models that attempt to explain the nature of subluminous X-ray transients. Our estimates lie in the range of 3E-13 Msun/yr systems are neutron star X-ray binaries and between 4E-14 Msun/yr systems have such low estimated mass-accretion rates that they possibly pose a challenge for binary evolution models.

  13. Automatic detection of bone fragments in poultry using multi-energy x-rays

    DOE Patents [OSTI]

    Gleason, Shaun S. (Knoxville, TN); Paulus, Michael J. (Knoxville, TN); Mullens, James A. (Knoxville, TN)

    2002-04-09

    At least two linear arrays of x-ray detectors are placed below a conveyor belt in a poultry processing plant. Multiple-energy x-ray sources illuminate the poultry and are detected by the detectors. Laser profilometry is used to measure the poultry thickness as the x-ray data is acquired. The detector readout is processed in real time to detect the presence of small highly attenuating fragments in the poultry, i.e., bone, metal, and cartilage.

  14. HARD X-RAY AND MICROWAVE FLUX SPECTRA OF THE 2 NOVEMBER 1991 SOLAR FLARE

    E-Print Network [OSTI]

    HARD X-RAY AND MICROWAVE FLUX SPECTRA OF THE 2 NOVEMBER 1991 SOLAR FLARE CHIK-YIN LEE1,2 and HAIMIN analysed the hard X-ray and microwave flux spectra of the solar flare (BATSE No. 1791) on 2 November 1991 for this study. This paper studies the hard X-ray and microwave spectra of the solar flare on 2 November 1991

  15. Week 2 AGENDA: National School on Neutron and X-ray Scattering page 1 of 5 Oak Ridge National Laboratory [9/30/08

    E-Print Network [OSTI]

    Pennycook, Steve

    Week 2 AGENDA: National School on Neutron and X-ray Scattering page 1 of 5 Oak Ridge National Ridge National Laboratory Dean Myles, Director ORNL Neutron Scattering Science Division 1 GROUPS [A,B,C,D,E,F,G,H,I] Iran Thomas Auditorium Lecture Inelastic Neutron Scattering R. Osborn, ANL ALL

  16. Sequential Threat Detection for Harbor Defense: An X-ray Physics...

    Office of Scientific and Technical Information (OSTI)

    Sequential Threat Detection for Harbor Defense: An X-ray Physics-Based Bayesian Approach Citation Details In-Document Search Title: Sequential Threat Detection for Harbor Defense:...

  17. Fifteenth international conference on X-ray and inner-shell processes

    SciTech Connect (OSTI)

    Not Available

    1990-01-01

    This document is composed of Abstracts from invited papers presented at X-90, the fifteenth annual international conference on x-ray and Inner-Shell Processes. (FSD)

  18. X-Ray Characterization of Diesel Sprays and the Effects of Nozzle...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Sprays and the Effects of Nozzle Geometry X-Ray Characterization of Diesel Sprays and the Effects of Nozzle Geometry 2004 Diesel Engine Emissions Reduction (DEER) Conference...

  19. Ray tracing flux calculation for the small and wide angle x-ray...

    Office of Scientific and Technical Information (OSTI)

    station at the SESAME synchrotron radiation facility The calculation for the optics of the synchrotron radiation small and wide angle x-ray scattering beamline, currently...

  20. Soft X-Ray Diffraction Microscopy of a Frozen Hydrated Yeast Cell

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Huang, Xiaojing; Nelson, Johanna; Kirz, Janos; Lima, Enju; Marchesini, Stefano; Miao, Huijie; Neiman, Aaron M.; Shapiro, David; Steinbrener, Jan; Stewart, Andrew; et al

    2009-11-01

    We report the first image of an intact, frozen hydrated eukaryotic cell using x-ray diffraction microscopy, or coherent x-ray diffraction imaging. By plunge freezing the specimen in liquid ethane and maintaining it below -170 °C, artifacts due to dehydration, ice crystallization, and radiation damage are greatly reduced. In this example, coherent diffraction data using 520 eV x rays were recorded and reconstructed to reveal a budding yeast cell at a resolution better than 25 nm. This demonstration represents an important step towards high resolution imaging of cells in their natural, hydrated state, without limitations imposed by x-ray optics.

  1. IGR J17098-3628: an X-ray Nova discovered by INTEGRAL

    E-Print Network [OSTI]

    S. A. Grebenev; S. V. Molkov; M. G. Revnivtsev; R. A. Sunyaev

    2007-09-14

    We report the discovery with INTEGRAL on March 24, 2005, and follow-up observations of the distant Galactic X-ray nova IGR J17098-3628.

  2. Monochromatic x-ray sampling streak imager for fast-ignitor plasma observation

    SciTech Connect (OSTI)

    Tanabe, Minoru; Fujiwara, Takashi; Fujioka, Shinsuke; Nishimura, Hiroaki; Shiraga, Hiroyuki; Azechi, Hiroshi; Mima, Kunioki

    2008-10-15

    Ultrafast two-dimensional (2D) x-ray imaging is required to investigate the dynamics of fast-heated core plasma in inertial confinement fusion research. A novel x-ray imager, consisting of two toroidally bent Bragg crystals and an ultrafast 2D x-ray imaging camera, has been demonstrated. Sequential and 2D monochromatic x-ray images of laser-imploded core plasma were obtained with a temporal resolution of 20 ps, a spatial resolution of 31 {mu}m, and a spectral resolution of over 200, simultaneously.

  3. Soft X-Ray Diffraction Microscopy of a Frozen Hydrated Yeast Cell

    SciTech Connect (OSTI)

    Huang Xiaojing; Nelson, Johanna; Lima, Enju; Miao, Huijie; Steinbrener, Jan; Stewart, Andrew; Turner, Joshua J.; Jacobsen, Chris; Kirz, Janos; Marchesini, Stefano; Shapiro, David; Neiman, Aaron M.

    2009-11-06

    We report the first image of an intact, frozen hydrated eukaryotic cell using x-ray diffraction microscopy, or coherent x-ray diffraction imaging. By plunge freezing the specimen in liquid ethane and maintaining it below -170 deg. C, artifacts due to dehydration, ice crystallization, and radiation damage are greatly reduced. In this example, coherent diffraction data using 520 eV x rays were recorded and reconstructed to reveal a budding yeast cell at a resolution better than 25 nm. This demonstration represents an important step towards high resolution imaging of cells in their natural, hydrated state, without limitations imposed by x-ray optics.

  4. Generation of stable subfemtosecond hard x-ray pulses with optimized...

    Office of Scientific and Technical Information (OSTI)

    optimized nonlinear bunch compression Citation Details In-Document Search Title: Generation of stable subfemtosecond hard x-ray pulses with optimized nonlinear bunch...

  5. Reliable before-fabrication forecasting of expected surface slope distributions for x-ray optics

    E-Print Network [OSTI]

    Yashchuk, Yekaterina V.

    2013-01-01

    of x-ray optics for the LCLS free-electron laser,” Proc.beamlines and diagnostics at LCLS,” Nucl. Instrum. Methods A

  6. Suzaku Reveals Helium-burning Products in the X-ray Emitting Planetary Nebula BD+303639

    E-Print Network [OSTI]

    M. Murashima; M. Kokubun; K. Makishima; J. Kotoku; H. Murakami; K. Matsushita; K. Hayashida; K. Arnaud; K. Hamaguchi; H. Matsumoto

    2006-07-07

    BD+303639, the brightest planetary nebula at X-ray energies, was observed with Suzaku, an X-ray observatory launched on 2005 July 10. Using the X-ray Imaging Spectrometer, the K-lines from C VI, O VII, and O VIII were resolved for the first time, and C/O, N/O, and Ne/O abundance ratios determined. The C/O and Ne/O abundance ratios exceed the solar value by a factor of at least 30 and 5, respectively. These results indicate that the X-rays are emitted mainly by helium shell-burning products.

  7. Modeling X-ray Emission Line Profiles from Massive Star Winds - A Review

    E-Print Network [OSTI]

    Ignace, Richard

    2016-01-01

    The Chandra and XMM-Newton X-ray telescopes have led to numerous advances in the study and understanding of astrophysical X-ray sources. Particularly important has been the much increased spectral resolution of modern X-ray instrumentation. Wind-broadened emission lines have been spectroscopically resolved for many massive stars. This contribution reviews approaches to the modeling of X-ray emission line profile shapes from single stars, including smooth winds, winds with clumping, optically thin versus thick lines, and the effect of a radius-dependent photoabsorption coefficient.

  8. A laboratory based system for Laue micro x-ray diffraction

    E-Print Network [OSTI]

    Lynch, P. A.; Advanced Light Source

    2008-01-01

    A laboratory based system for Laue micro x-ray diffractionLawrence Berkeley National Laboratory, 1 Cyclotron Road,Berkeley, California 94720 A laboratory diffraction system

  9. TH SSRL SCHOOL ON SYNCHROTRON X-RAY SCATTERING TECHNIQUES IN...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    TH SSRL SCHOOL ON SYNCHROTRON X-RAY SCATTERING TECHNIQUES IN MATERIALS AND ENVIRONMENTAL SCIENCES: THEORY AND APPLICATION TUESDAY 03 JUNE THURSDAY 05 JUNE 2014 Last update: 02...

  10. INTERMEDIATE ENERGY X-RAY (IEX) BEAMLINE AT THE ADVANCED PHOTON...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    INTERMEDIATE ENERGY X-RAY (IEX) BEAMLINE AT THE ADVANCED PHOTON SOURCE Jessica McChesney, APS beamline scientist, connecting the transition edge sensor (TES) detector to the...

  11. X-ray evaluation of coke-oven gas line deposits

    SciTech Connect (OSTI)

    Swain, Y.T.

    1983-08-01

    Control of coke-oven gas pipeline deposits has been facilitated through the use of an X-ray technique that provides quantitative data without disrupting plant operations.

  12. X-ray Image Bank Open for Business - NERSC Center News, Feb 22...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    use light sources to shoot intense x-ray beams into molecules, such as proteins, in order to understand their shapes and structures. The resulting diffraction patterns are...

  13. Absolute timing measurements of the Ni-like Pd and Sn soft-x-ray lasers

    SciTech Connect (OSTI)

    Staub, F.; Braud, M.; Balmer, J.E.; Nilsen, J.

    2005-10-15

    The absolute time of emission of the x-ray laser output with respect to the arrival of a 100-ps pump pulse has been measured with the aid of a calibrated timing fiducial. The results show the x-ray laser to appear up to 60 ps (80 ps) before the peak of the pump pulse in the case of the Sn (Pd) x-ray laser, which is in good agreement with simulations obtained from the LASNEX and CRETIN codes. The pulse duration was found to be {approx}45 ps for both the Sn and the Pd x-ray lasers.

  14. X-rays from Radio-Galaxies: BeppoSAX Observations

    E-Print Network [OSTI]

    Paola Grandi; C. Meg Urry; Laura Maraschi

    2000-04-20

    We briefly review BeppoSAX observations of X-ray bright radio-galaxies. Their X-ray spectra are quite varied, and perhaps surprisingly, any similarity between radio-loud AGN and Seyfert galaxies is the exception rather than the rule. When detected, reprocessing features (iron line and reflection) are generally weak, suggesting two possible scenarios: either: (1) non-thermal (jet?) radiation dilutes the X-ray emission from the disk in radio-loud objects, or (2) the solid angle subtended by the X-ray reprocessing material is smaller in radio-loud than in radio-quiet AGN due to different characteristics of the accretion disk itself.

  15. X-Ray Imaging of the Dynamic Magnetic Vortex Core Deformation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorkingLos Alamos verifies largest single goldWind PowerX-RayX-RayX-RayX-Ray

  16. X-ray studies of concentrated aqueous solutions

    SciTech Connect (OSTI)

    Ludwig, K.F. Jr.; Warburton, W.K.; Fontaine, A.

    1987-07-01

    Concentrated aqueous solutions of three transition metal bromides (ZnBr/sub 2/, CuBr/sub 2/, and NiBr/sub 2/) and an alkali bromide (RbBr) have been studied with differential anomalous scattering (DAS) and extended x-ray absorption fine structure (EXAFS). The aq-ZnBr/sub 2/ solutions exhibit considerable inner-shell ion complexing with the formation of tetrahedral complexes about the Zn/sup 2 +/. In aq-CuBr/sub 2/, the Cu/sup 2 +/ has an octahedral coordination shell. Most of the anions are bound directly to the cations in both solutions. In contrast, there are only a few Ni--Br nearest neighbors in aq-NiBr/sub 2/. Instead, cations and anions share hydrating water molecules. Preliminary data show that any ion complexing in aq-RbBr must be weak. These results are in good agreement with published thermodynamic studies.

  17. Soft x-ray undulator for the Siam Photon Source

    SciTech Connect (OSTI)

    Rugmai, S.; Dasri, T.; Prawanta, S.; Siriwattanapaitoon, S.; Kwankasem, A.; Sooksrimuang, V.; Chachai, W.; Suradet, N.; Juthong, N.; Tancharakorn, S.

    2007-01-19

    An undulator for production of intense soft x-rays has been designed for the Siam Photon Source. The construction of the undulator has been completed. It is now being characterized and prepared for installation. The device, named U60, is a pure permanent magnet planar undulator, consisting of 41 magnetic periods, with 60 mm period length. Utilization of the undulator radiation in the photon energy range of 30 - 900 eV is expected. The design studies of the magnetic structure, including investigation of perturbations arising from the magnetic field of the device, their effects on the SPS storage ring and compensation schemes are described. A magnetic measurement system has been constructed for magnetic characterization of the device. Partial results of magnetic measurements are presented.

  18. The centrifugal force reversal and X-ray bursts

    E-Print Network [OSTI]

    M. A. Abramowicz; W. Kluzniak; J. -P. Lasota

    2001-06-15

    Heyl (2000) made an interesting suggestion that the observed shifts in QPO frequency in type I X-ray bursts could be influenced by the same geometrical effect of strong gravity as the one that causes centrifugal force reversal discovered by Abramowicz and Lasota (1974). However, his main result contains a sign error. Here we derive the correct formula and conclude that constraints on the M(R) relation for neutron stars deduced from the rotational-modulation model of QPO frequency shifts are of no practical interest because the correct formula implies a weak condition R* > 1.3 Rs, where Rs is the Schwarzschild radius. We also argue against the relevance of the rotational-modulation model to the observed frequency modulations.

  19. X-ray spectroscopy of the supernova remnant RCW 86

    E-Print Network [OSTI]

    Jacco Vink; Jelle Kaastra; Johan Bleeker

    1997-09-12

    We present an analysis of ASCA X-ray data of SNR RCW 86. There appears to be a remarkable spectral variation over the remnant, indicating temperatures varying from 0.8 keV to > 3 keV. We have fitted these spectra with non-equilibrium ionization models and found that all regions are best fitted by emission from a hot plasma underabundant in metals (<0.25 solar), but in some cases fluorescent emission indicates overabundances of Ar and Fe. The ionization stage of the metals appears to be far from equilibrium, at some spots as low as log(n_e t) 15.3 (SI units). We discuss the physical reality of the abundances and suggest an electron distribution with a supra-thermal tail to alleviate the strong depletion factors observed. We argue that RCW 86 is the result of a cavity explosion.

  20. High efficiency replicated x-ray optics and fabrication method

    DOE Patents [OSTI]

    Barbee, Jr., Troy W. (Palo Alto, CA); Lane, Stephen M. (Oakland, CA); Hoffman, Donald E. (Fremont, CA)

    2001-01-01

    Replicated x-ray optics are fabricated by sputter deposition of reflecting layers on a super-polished reusable mandrel. The reflecting layers are strengthened by a supporting multilayer that results in stronger stress-relieved reflecting surfaces that do not deform during separation from the mandrel. The supporting multilayer enhances the ability to part the replica from the mandrel without degradation in surface roughness. The reflecting surfaces are comparable in smoothness to the mandrel surface. An outer layer is electrodeposited on the supporting multilayer. A parting layer may be deposited directly on the mandrel before the reflecting surface to facilitate removal of the layered, tubular optic device from the mandrel without deformation. The inner reflecting surface of the shell can be a single layer grazing reflection mirror or a resonant multilayer mirror. The resulting optics can be used in a wide variety of applications, including lithography, microscopy, radiography, tomography, and crystallography.

  1. Air-core grid for scattered x-ray rejection

    DOE Patents [OSTI]

    Logan, Clinton M. (Pleasanton, CA); Lane, Stephen M. (Oakland, CA)

    1995-01-01

    The invention is directed to a grid used in x-ray imaging applications to block scattered radiation while allowing the desired imaging radiation to pass through, and to process for making the grid. The grid is composed of glass containing lead oxide, and eliminates the spacer material used in prior known grids, and is therefore, an air-core grid. The glass is arranged in a pattern so that a large fraction of the area is open allowing the imaging radiation to pass through. A small pore size is used and the grid has a thickness chosen to provide high scatter rejection. For example, the grid may be produced with a 200 .mu.m pore size, 80% open area, and 4 mm thickness.

  2. X-ray Moiré deflectometry using synthetic reference images

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Stutman, Dan; Valdivia, Maria Pia; Finkenthal, Michael

    2015-06-25

    Moiré fringe deflectometry with grating interferometers is a technique that enables refraction-based x-ray imaging using a single exposure of an object. To obtain the refraction image, the method requires a reference fringe pattern (without the object). Our study shows that, in order to avoid artifacts, the reference pattern must be exactly matched in phase with the object fringe pattern. In experiments, however, it is difficult to produce a perfectly matched reference pattern due to unavoidable interferometer drifts. We present a simple method to obtain matched reference patterns using a phase-scan procedure to generate synthetic Moiré images. As a result, themore »method will enable deflectometric diagnostics of transient phenomena such as laser-produced plasmas and could improve the sensitivity and accuracy of medical phase-contrast imaging.« less

  3. Near Infrared observations of Soft X-ray selected AGN

    E-Print Network [OSTI]

    D. Grupe; H. -C Thomas

    2002-02-21

    We report the results of near infrared observations of 19 soft X-ray selected AGN. The goal of the observations was to search for strong, narrow Paschen-alpha or Brackett-gamma emission lines, as a sign of nuclear starbursts. We found Pa-alpha emission in the spectra of 11 sources and Br-gamma in at least five. Strong NIR emission has been found in two sources, CBS 126 and Mkn 766, both objects with strong [OIII]5007 emission, weak FeII emission and wavelength dependent degree of polarization in the optical. Classical Narrow Line Seyfert 1 galaxies do not show exceptionally strong NIR emission lines. We present the results of our study and discuss how our findings fit into an evolutionary scheme of AGN.

  4. Advances in x-ray computed microtomography at the NSLS

    SciTech Connect (OSTI)

    Dowd, B.A.; Andrews, A.B.; Marr, R.B.; Siddons, D.P.; Jones, K.W.; Peskin, A.M.

    1998-08-01

    The X-Ray Computed Microtomography workstation at beamline X27A at the NSLS has been utilized by scientists from a broad range of disciplines from industrial materials processing to environmental science. The most recent applications are presented here as well as a description of the facility that has evolved to accommodate a wide variety of materials and sample sizes. One of the most exciting new developments reported here resulted from a pursuit of faster reconstruction techniques. A Fast Filtered Back Transform (FFBT) reconstruction program has been developed and implemented, that is based on a refinement of the gridding algorithm first developed for use with radio astronomical data. This program has reduced the reconstruction time to 8.5 sec for a 929 x 929 pixel{sup 2} slice on an R10,000 CPU, more than 8x reduction compared with the Filtered Back-Projection method.

  5. Hyperspectral image reconstruction for x-ray fluorescence tomography

    SciTech Connect (OSTI)

    Gürsoy, Do?a; Biçer, Tekin; Lanzirotti, Antonio; Newville, Matthew G.; De Carlo, Francesco

    2015-01-01

    A penalized maximum-likelihood estimation is proposed to perform hyperspectral (spatio-spectral) image reconstruction for X-ray fluorescence tomography. The approach minimizes a Poisson-based negative log-likelihood of the observed photon counts, and uses a penalty term that has the effect of encouraging local continuity of model parameter estimates in both spatial and spectral dimensions simultaneously. The performance of the reconstruction method is demonstrated with experimental data acquired from a seed of arabidopsis thaliana collected at the 13-ID-E microprobe beamline at the Advanced Photon Source. The resulting element distribution estimates with the proposed approach show significantly better reconstruction quality than the conventional analytical inversion approaches, and allows for a high data compression factor which can reduce data acquisition times remarkably. In particular, this technique provides the capability to tomographically reconstruct full energy dispersive spectra without compromising reconstruction artifacts that impact the interpretation of results.

  6. Theoretical X-ray Line Profiles from Colliding Wind Binaries

    E-Print Network [OSTI]

    Henley, D B; Pittard, J M

    2003-01-01

    We present theoretical X-ray line profiles from a range of model colliding wind systems. In particular, we investigate the effects of varying the stellar mass-loss rates, the wind speeds, and the viewing orientation. We find that a wide range of theoretical line profile shapes is possible, varying with orbital inclination and phase. At or near conjunction, the lines have approximately Gaussian profiles, with small widths (HWHM ~ 0.1 v_infty) and definite blue- or redshifts (depending on whether the star with the weaker wind is in front or behind). When the system is viewed at quadrature, the lines are generally much broader (HWHM ~ v_infty), flat-topped and unshifted. Local absorption can have a major effect on the observed profiles - in systems with mass-loss rates of a few times 10^{-6} Msol/yr the lower energy lines (E wind of the primary. The orbital variation ...

  7. Optical synchronization system for femtosecond X-ray sources

    DOE Patents [OSTI]

    Wilcox, Russell B. (El Cerrito, CA); Holzwarth, Ronald (Munich, DE)

    2011-12-13

    Femtosecond pump/probe experiments using short X-Ray and optical pulses require precise synchronization between 100 meter-10 km separated lasers in a various experiments. For stabilization in the hundred femtosecond range a CW laser is amplitude modulated at 1-10 GHz, the signal retroreflected from the far end, and the relative phase used to correct the transit time with various implementations. For the sub-10 fsec range the laser frequency itself is upshifted 55 MHz with an acousto-optical modulator, retroreflected, upshifted again and phase compared at the sending end to a 110 MHz reference. Initial experiments indicate less than 1 fsec timing jitter. To lock lasers in the sub-10 fs range two single-frequency lasers separated by several teraHertz will be lock to a master modelocked fiber laser, transmit the two frequencies over fiber, and lock two comb lines of a slave laser to these frequencies, thus synchronizing the two modelocked laser envelopes.

  8. Hyperspectral image reconstruction for x-ray fluorescence tomography

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Gürsoy, Do?a; Biçer, Tekin; Lanzirotti, Antonio; Newville, Matthew G.; De Carlo, Francesco

    2015-01-01

    A penalized maximum-likelihood estimation is proposed to perform hyperspectral (spatio-spectral) image reconstruction for X-ray fluorescence tomography. The approach minimizes a Poisson-based negative log-likelihood of the observed photon counts, and uses a penalty term that has the effect of encouraging local continuity of model parameter estimates in both spatial and spectral dimensions simultaneously. The performance of the reconstruction method is demonstrated with experimental data acquired from a seed of arabidopsis thaliana collected at the 13-ID-E microprobe beamline at the Advanced Photon Source. The resulting element distribution estimates with the proposed approach show significantly better reconstruction quality than the conventional analytical inversionmore »approaches, and allows for a high data compression factor which can reduce data acquisition times remarkably. In particular, this technique provides the capability to tomographically reconstruct full energy dispersive spectra without compromising reconstruction artifacts that impact the interpretation of results.« less

  9. X-ray detectors at the Linac Coherent Light Source

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Blaj, Gabriel; Caragiulo, Pietro; Carini, Gabriella; Carron, Sebastian; Dragone, Angelo; Freytag, Dietrich; Haller, Gunther; Hart, Philip; Hasi, Jasmine; Herbst, Ryan; et al

    2015-04-21

    Free-electron lasers (FELs) present new challenges for camera development compared with conventional light sources. At SLAC a variety of technologies are being used to match the demands of the Linac Coherent Light Source (LCLS) and to support a wide range of scientific applications. In this paper an overview of X-ray detector design requirements at FELs is presented and the various cameras in use at SLAC are described for the benefit of users planning experiments or analysts looking at data. Features and operation of the CSPAD camera, which is currently deployed at LCLS, are discussed, and the ePix family, a newmore »generation of cameras under development at SLAC, is introduced.« less

  10. Air-core grid for scattered x-ray rejection

    DOE Patents [OSTI]

    Logan, C.M.; Lane, S.M.

    1995-10-03

    The invention is directed to a grid used in x-ray imaging applications to block scattered radiation while allowing the desired imaging radiation to pass through, and to process for making the grid. The grid is composed of glass containing lead oxide, and eliminates the spacer material used in prior known grids, and is therefore, an air-core grid. The glass is arranged in a pattern so that a large fraction of the area is open allowing the imaging radiation to pass through. A small pore size is used and the grid has a thickness chosen to provide high scatter rejection. For example, the grid may be produced with a 200 {micro}m pore size, 80% open area, and 4 mm thickness. 2 figs.

  11. X-ray Spectroscopy for Quality Control of Chemotherapy Drugs

    SciTech Connect (OSTI)

    Greaves, E. D.; Barros, H.; Bermudez, J.; Sajo-Bohus, L.; Angeli-Greaves, M.

    2007-10-26

    We develop a method, employing Compton peak standardization and the use of matrix-matched spiked samples with Total Reflection X-ray Fluorescence (TXRF), for the determination of platinum plasma concentrations of patients undergoing chemotherapy with Pt-bearing drugs. Direct blood plasma analysis attains Pt detection limits of 70 ng/ml. Measurement results of prescribed drug doses are compared to achieved blood Pt concentrations indicating a lack of expected correlations. Direct analysis of Pt-containing infused drugs from a variety of suppliers indicates cases of abnormal concentrations which raises quality control issues. We demonstrate the potential usefulness of the method for pharmacokinetic studies or for routine optimization and quality control of Pt chemotherapy treatments.

  12. Variable-metric diffraction crystals for x-ray optics

    SciTech Connect (OSTI)

    Smither, R.K.; Fernandez, P.B. )

    1992-02-01

    A variable-metric (VM) crystal is one in which the spacing between the crystalline planes changes with position in the crystal. This variation can be either parallel to the crystalline planes or perpendicular to the crystalline planes of interest and can be produced by either introducing a thermal gradient in the crystal or by growing a crystal made of two or more elements and changing the relative percentages of the two elements as the crystal is grown. A series of experiments were performed in the laboratory to demonstrate the principle of the variable-metric crystal and its potential use in synchrotron beam lines. One of the most useful applications of the VM crystal is to increase the number of photons per unit bandwidth in a diffracted beam without losing any of the overall intensity. In a normal synchrotron beam line that uses a two-crystal monochromator, the bandwidth of the diffracted photon beam is determined by the vertical opening angle of the beam which is typically 0.10--0.30 mrad or 20--60 arcsec. When the VM crystal approach is applied, the bandwidth of the beam can be made as narrow as the rocking curve of the diffracting crystal, which is typically 0.005--0.050 mrad or 1--10 arcsec. Thus a very large increase of photons per unit bandwidth (or per unit energy) can be achieved through the use of VM crystals. When the VM principle is used with bent crystals, new kinds of x-ray optical elements can be generated that can focus and defocus x-ray beams much like simple lenses where the focal length of the lens can be changed to match its application. Thus both large magnifications and large demagnifications can be achieved as well as parallel beams with narrow bandwidths.

  13. Results from the NSTX X-ray Crystal Spectrometer

    SciTech Connect (OSTI)

    M. Bitter; K. Hill; L. Roquemore; P. Beiersdorfer; D. Thorn; Ming Feng Gu

    2003-01-14

    A high-resolution X-ray crystal spectrometer has recently been installed at the National Spherical Torus Experiment to record the satellite spectra of helium-like argon, ArXVII, in the wavelength range from 3.94 to 4.00 {angstrom} for measurements of ion and electron temperatures, and measurements of the ionization equilibrium of argon, which is of interest for studies of ion transport. The instrument presently consists of a spherically bent quartz crystal and a conventional one-dimensional position-sensitive multi-wire proportional counter, but it will soon be upgraded to a new type of X-ray imaging crystal spectrometer by the installation of a large size (10 cm x 30 cm) two-dimensional position-sensitive detector that will allow us to obtain temporally and spatially resolved spectra from an 80 cm high cross-section of the plasma. In its present configuration, the spectrometer has been optimized for high throughput so that it is possible to record spectra with small statistical errors with a time resolution of 10 ms by adding only small, nonperturbing amounts of argon to the plasma. The spectrometer is most valuable for measurements of the ion temperature in the absence of a neutral beam in ohmically heated and radio-frequency heated discharges, when charge exchange recombination spectroscopy does not function. Electron temperature measurements from the satellite-to-resonance line ratios have been important for a quantitative comparison with (and verification of) the Thomson scattering data. The paper will describe the instrumental details of the present and future spectrometer configurations, and present recent experimental results.

  14. X-ray Computed Tomography of coal: Final report

    SciTech Connect (OSTI)

    Maylotte, D.H.; Spiro, C.L.; Kosky, P.G.; Lamby, E.J.

    1986-12-01

    X-ray Computed Tomography (CT) is a method of mapping with x-rays the internal structures of coal. The technique normally produces 2-D images of the internal structures of an object. These images can be recast to create pseudo 3-D representations. CT of coal has been explored for a variety of different applications to coal and coal processing technology. In a comparison of CT data with conventional coal analyses and petrography, CT was found to offer a good indication of the total ash content of the coal. The spatial distribution of the coal mineral matter as seen with CT has been suggested as an indicator of coal washability. Studies of gas flow through coal using xenon gas as a tracer have shown the extremely complicated nature of the modes of penetration of gas through coal, with significant differences in the rates at which the gas can pass along and across the bedding planes of coal. In a special furnace designed to allow CT images to be taken while the coal was being heated, the pyrolysis and gasification of coal have been studied. Gasification rates with steam and CO/sub 2/ for a range of coal ranks have been obtained, and the location of the gasification reactions within the piece of coal can be seen. Coal drying and the progress of the pyrolysis wave into coal have been examined when the coal was subjected to the kind of sudden temperature jump that it might experience in fixed bed gasifier applications. CT has also been used to examine stable flow structures within model fluidized beds and the accessibility of lump coal to microbial desulfurization. 53 refs., 242 figs., 26 tabs.

  15. OPTICAL COUNTERPARTS OF THE NEAREST ULTRALUMINOUS X-RAY SOURCES

    SciTech Connect (OSTI)

    Gladstone, Jeanette C.; Heinke, Craig O.; Cartwright, Taylor F. [Department of Physics, University of Alberta, 11322-89 Avenue, Edmonton, Alberta T6G 2G7 (Canada)] [Department of Physics, University of Alberta, 11322-89 Avenue, Edmonton, Alberta T6G 2G7 (Canada); Copperwheat, Chris [Department of Physics, Liverpool John Moores University, Wirral CH41 1LD (United Kingdom)] [Department of Physics, Liverpool John Moores University, Wirral CH41 1LD (United Kingdom); Roberts, Timothy P. [Department of Physics, University of Durham, South Road, Durham DH1 3LE (United Kingdom)] [Department of Physics, University of Durham, South Road, Durham DH1 3LE (United Kingdom); Levan, Andrew J. [Department of Physics, University of Warwick, Coventry CV4 7VL (United Kingdom)] [Department of Physics, University of Warwick, Coventry CV4 7VL (United Kingdom); Goad, Mike R., E-mail: j.c.gladstone@ualberta.ca [Department of Physics and Astronomy, University of Leicester, University Road, Leicester LE1 7AL (United Kingdom)

    2013-06-01

    We present a photometric survey of the optical counterparts of ultraluminous X-ray sources (ULXs) observed with the Hubble Space Telescope (HST) in nearby ({approx}<5 Mpc) galaxies. Of the 33 ULXs with HST and Chandra data, 9 have no visible counterpart, placing limits on their M{sub V} of {approx} -4 to -9, enabling us to rule out O-type companions in 4 cases. The refined positions of two ULXs place them in the nucleus of their host galaxy. They are removed from our sample. Of the 22 remaining ULXs, 13 have one possible optical counterpart, while multiple are visible within the error regions of other ULXs. By calculating the number of chance coincidences, we estimate that 13 {+-} 5 are the true counterparts. We attempt to constrain the nature of the companions by fitting the spectral energy distribution and M{sub V} to obtain candidate spectral types. We can rule out O-type companions in 20 cases, while we find that one ULX (NGC 253 ULX2) excludes all OB-type companions. Fitting with X-ray irradiated models provides constraints on the donor star mass and radius. For seven ULXs, we are able to impose inclination-dependent upper and/or lower limits on the black holes' mass, if the extinction to the assumed companion star is not larger than the Galactic column. These are NGC 55 ULX1, NGC 253 ULX1, NGC 253 ULX2, NGC 253 XMM6, Ho IX X-1, IC342 X-1, and NGC 5204 X-1. This suggests that 10 ULXs do not have O companions, while none of the 18 fitted rule out B-type companions.

  16. Constraining Black Hole Spin Via X-ray Spectroscopy

    E-Print Network [OSTI]

    Laura W. Brenneman; Christopher S. Reynolds

    2006-08-23

    We present an analysis of the observed broad iron line feature and putative warm absorber in the long 2001 XMM-Newton observation of the Seyfert-1.2 galaxy MCG-6-30-15. The new "kerrdisk" model we have designed for simulating line emission from accretion disk systems allows black hole spin to be a free parameter in the fit, enabling the user to formally constrain the angular momentum of a black hole, among other physical parameters of the system. In an important extension of previous work, we derive constraints on the black hole spin in MCG-6-30-15 using a self-consistent model for X-ray reflection from the surface of the accretion disk while simultaneously accounting for absorption by dusty photoionized material along the line of sight (the warm absorber). Even including these complications, the XMM-Newton/EPIC-pn data require extreme relativistic broadening of the X-ray reflection spectrum; assuming no emission from within the radius of marginal stability, we derive a formal constraint on the dimensionless black hole spin parameter of a > 0.987 at 90% confidence. The principal unmodeled effect that can significantly reduce the inferred black hole spin is powerful emission from within the radius of marginal stability. Although significant theoretical developments are required to fully understand this region, we argue that the need for a rapidly spinning black hole is robust to physically plausible levels of emission from within the radius of marginal stability. In particular, we show that a non-rotating black hole is strongly ruled out.

  17. Crystallization and preliminary X-ray crystallographic analysis of a galactose-specific lectin from Dolichos lablab

    SciTech Connect (OSTI)

    Lavanya Latha, V.; Kulkarni, Kiran A. [Molecular Biophysics Unit, Indian Institute of Science, Bangalore 560 012 (India); Nagender Rao, R.; Siva Kumar, N. [Department of Biochemistry, University of Hyderabad, Hyderabad 500 046 (India); Suguna, K., E-mail: suguna@mbu.iisc.ernet.in [Molecular Biophysics Unit, Indian Institute of Science, Bangalore 560 012 (India)

    2006-02-01

    The galactose-specific lectin from the seeds of a leguminous plant, D. lablab, has been crystallized. Molecular-replacement solution using 3.0 Å X-ray diffraction data showed the lectin to be a tetramer. The galactose-specific lectin from the seeds of Dolichos lablab has been crystallized using the hanging-drop vapour-diffusion technique. The crystals belong to space group P1, with unit-cell parameters a = 73.99, b = 84.13, c = 93.15 Å, ? = 89.92, ? = 76.01, ? = 76.99°. X-ray diffraction data to a resolution of 3.0 Å have been collected under cryoconditions (100 K) using a MAR imaging-plate detector system mounted on a rotating-anode X-ray generator. Molecular-replacement calculations carried out using the available structures of legume lectins as search models revealed that the galactose-specific lectin from D. lablab forms a tetramer similar to soybean agglutinin; two such tetramers are present in the asymmetric unit.

  18. Low and Room Temperature X-ray Structures of Protein Kinase A Ternary Complexes Shed New Light on Its Activity

    SciTech Connect (OSTI)

    Fisher, Zoe; Hanson, Leif; Kovalevsky, Andrey; Langan, Paul

    2012-01-01

    Posttranslational protein phosphorylation by protein kinase A (PKA) is a ubiquitous signaling mechanism which regulates many cellular processes. A low temperature X-ray structure of the PKA catalytic subunit (PKAc) ternary complex with ATP and a 20-residue peptidic inhibitor (IP20) at the physiological Mg2+ concentration of < 0.5mM revealed a single metal ion in the active site. The lack of a second metal in the low-temperature LT-PKAc-MgATP-IP20 renders the and phosphoryl groups of ATP to be very flexibile, with high thermal B-factors. Thus, the second metal is crucial for tight positioning of the terminal phosphoryl for transfer to a substrate, as demonstrated by comparison of the former structure with LT-PKAc- Mg2ATP-IP20 complex. In addition to the kinase activity, PKAc is also able to slowly catalyze the hydrolysis of ATP using a water molecule as a substrate. We found that at room temperature under X-ray irradiation ATP can be readily and completely hydrolyzed into ATP and a free phosphate ion in the crystals of the ternary complex LT-PKAc- Mg2ATP-IP20. The cleavage of ATP may be aided by X-ray-born free hydroxyl radicals, a very reactive chemical species, that move quickly through the crystal at room temperature. The phosphate anion is clearly visible in the electron density maps; it remains in the active site, but slides about 2 from its position in ATP toward Ala21 of IP20 that mimics the phosphorylation site. The phosphate, thus, pushes the peptidic inhibitor away from the product ADP, while resulting in dramatic conformational changes of IP20 terminal residues 24 and 25. X-ray structures of PKAc in complex with non-hydrolyzable ATP analog, AMPPNP, at both room and low temperatures demonstrated no temperature effects on the conformation and position of IP20.

  19. Development of an X-ray pixel detector with multi-port charge-coupled device for X-ray free-electron laser experiments

    SciTech Connect (OSTI)

    Kameshima, Takashi; Ono, Shun; Kudo, Togo; Ozaki, Kyosuke; Kirihara, Yoichi; Kobayashi, Kazuo; Inubushi, Yuichi; Yabashi, Makina; Hatsui, Takaki; RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 ; Horigome, Toshio; Holland, Andrew; Holland, Karen; Burt, David; Murao, Hajime

    2014-03-15

    This paper presents development of an X-ray pixel detector with a multi-port charge-coupled device (MPCCD) for X-ray Free-Electron laser experiments. The fabrication process of the CCD was selected based on the X-ray radiation hardness against the estimated annual dose of 1.6 × 10{sup 14} photon/mm{sup 2}. The sensor device was optimized by maximizing the full well capacity as high as 5 Me- within 50 ?m square pixels while keeping the single photon detection capability for X-ray photons higher than 6 keV and a readout speed of 60 frames/s. The system development also included a detector system for the MPCCD sensor. This paper summarizes the performance, calibration methods, and operation status.

  20. New Directions in X-Ray Light Sources or Fiat Lux: what's under the dome and watching atoms with x-rays (LBNL Summer Lecture Series)

    ScienceCinema (OSTI)

    Falcone, Roger

    2011-04-28

    Summer Lecture Series 2008: Molecular movies of chemical reactions and material phase transformations need a strobe of x-rays, the penetrating light that reveals how atoms and molecules assemble in chemical and biological systems and complex materials. Roger Falcone, Director of the Advanced Light Source,will discuss a new generation of x ray sources that will enable a new science of atomic dynamics on ultrafast timescales.