Powered by Deep Web Technologies
Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

HVAC, Water Heating, and Appliances | Department of Energy  

Energy Savers [EERE]

HVAC, Water Heating, and Appliances HVAC, Water Heating, and Appliances How a Small Business is Transforming the Cold Climate Heating Market How a Small Business is Transforming...

2

Maryland Heats Up Student Appliance Design Competition | Department of  

Broader source: Energy.gov (indexed) [DOE]

Maryland Heats Up Student Appliance Design Competition Maryland Heats Up Student Appliance Design Competition Maryland Heats Up Student Appliance Design Competition September 10, 2013 - 11:43am Addthis Students from the University of Maryland won the Max Tech and Beyond Design Competition for their heat pump clothes dryer prototype, which achieved a 59 percent energy savings compared to standard U.S. electric dryers. | Photo courtesy of the University of Maryland. Students from the University of Maryland won the Max Tech and Beyond Design Competition for their heat pump clothes dryer prototype, which achieved a 59 percent energy savings compared to standard U.S. electric dryers. | Photo courtesy of the University of Maryland. Coming in a close second was The Ohio State University team with their design for a combination space cooling and water heating system for homes. The team received venture funding for the state of Ohio to continue developing their prototype, and the team plans to have a consumer-grade appliance ready for testing by summer 2014. | Photo courtesy of James Rowland, Student Team Lead, The Ohio State University

3

Building Technologies Office: Appliances Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Appliances Research to Appliances Research to someone by E-mail Share Building Technologies Office: Appliances Research on Facebook Tweet about Building Technologies Office: Appliances Research on Twitter Bookmark Building Technologies Office: Appliances Research on Google Bookmark Building Technologies Office: Appliances Research on Delicious Rank Building Technologies Office: Appliances Research on Digg Find More places to share Building Technologies Office: Appliances Research on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research Windows, Skylights, & Doors Research Space Heating & Cooling Research Water Heating Research Lighting Research Sensors & Controls Research Energy Efficient Buildings Hub Building Energy Modeling

4

Electric Blanket vs. Space Heater: #EnergyFaceoff Round 3 Heats...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Blanket vs. Space Heater: EnergyFaceoff Round 3 Heats Up Electric Blanket vs. Space Heater: EnergyFaceoff Round 3 Heats Up November 17, 2014 - 9:49am Q&A Which appliance do you...

5

The Pacific Northwest residential consumer: Perceptions and preferences of home heating fuels, major appliances, and appliance fuels  

SciTech Connect (OSTI)

In 1983 the Bonneville Power Administration contracted with the Pacific Northwest Laboratory (PNL) to conduct an analysis of the marketing environment for Bonneville's conservation activities. Since this baseline residential study, PNL has conducted two follow up market research projects: Phase 2 in 1985, and Phase 3, in 1988. In this report the respondents' perceptions, preferences, and fuel switching possibilities of fuels for home heating and major appliances are examined. To aid in effective target marketing, the report identifies market segments according to consumers' demographics, life-cycle, attitudes, and opinions.

Harkreader, S.A.; Hattrup, M.P.

1988-09-01T23:59:59.000Z

6

Total Space Heat-  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

Buildings Energy Consumption Survey: Energy End-Use Consumption Tables Total Space Heat- ing Cool- ing Venti- lation Water Heat- ing Light- ing Cook- ing Refrig- eration...

7

Passive solar space heating  

SciTech Connect (OSTI)

An overview of passive solar space heating is presented indicating trends in design, new developments, performance measures, analytical design aids, and monitored building results.

Balcomb, J.D.

1980-01-01T23:59:59.000Z

8

Conservation Division regiulations for appliance-efficiency standards relating to refrigerators and freezers, room air conditioners, central air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances  

SciTech Connect (OSTI)

The text of the appliance efficiency standards for certain types of new appliances sold in California is presented. Specifications and test methods to identify complying refrigerators, freezers, air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances are covered.

Not Available

1981-12-16T23:59:59.000Z

9

New Appliance Tax Credits, Rebates, and Incentives for Consumers |  

Broader source: Energy.gov (indexed) [DOE]

Appliance Tax Credits, Rebates, and Incentives for Consumers Appliance Tax Credits, Rebates, and Incentives for Consumers New Appliance Tax Credits, Rebates, and Incentives for Consumers September 8, 2009 - 11:16am Addthis Chris Stewart Senior Communicator at DOE's National Renewable Energy Laboratory Note: As of February 2012, the appliance rebate programs are closed. A couple of weeks ago, the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy announced a new appliance rebate program. Starting later this year and in early 2010, consumers will be able to receive rebates to purchase new ENERGY STAR-qualified appliances when they replace their used appliances. More than 70% of the energy used in our homes is for appliances, refrigeration, space heating, cooling, and water heating. Replacing old

10

Evaluation of Waste Heat Recovery and Utilization from Residential Appliances and Fixtures  

SciTech Connect (OSTI)

Executive Summary In every home irrespective of its size, location, age, or efficiency, heat in the form of drainwater or dryer exhaust is wasted. Although from a waste stream, this energy has the potential for being captured, possibly stored, and then reused for preheating hot water or air thereby saving operating costs to the homeowner. In applications such as a shower and possibly a dryer, waste heat is produced at the same time as energy is used, so that a heat exchanger to capture the waste energy and return it to the supply is all that is needed. In other applications such as capturing the energy in drainwater from a tub, dishwasher, or washing machine, the availability of waste heat might not coincide with an immediate use for energy, and consequently a heat exchanger system with heat storage capacity (i.e. a regenerator) would be necessary. This study describes a two-house experimental evaluation of a system designed to capture waste heat from the shower, dishwasher clothes washer and dryer, and to use this waste heat to offset some of the hot water energy needs of the house. Although each house was unoccupied, they were fitted with equipment that would completely simulate the heat loads and behavior of human occupants including operating the appliances and fixtures on a demand schedule identical to Building American protocol (Hendron, 2009). The heat recovery system combined (1) a gravity-film heat exchanger (GFX) installed in a vertical section of drainline, (2) a heat exchanger for capturing dryer exhaust heat, (3) a preheat tank for storing the captured heat, and (4) a small recirculation pump and controls, so that the system could be operated anytime that waste heat from the shower, dishwasher, clothes washer and dryer, and in any combination was produced. The study found capturing energy from the dishwasher and clothes washer to be a challenge since those two appliances dump waste water over a short time interval. Controls based on the status of the dump valve on these two appliances would have eliminated uncertainty in knowing when waste water was flowing and the recovery system operated. The study also suggested that capture of dryer exhaust heat to heat incoming air to the dryer should be examined as an alternative to using drying exhaust energy for water heating. The study found that over a 6-week test period, the system in each house was able to recover on average approximately 3000 W-h of waste heat daily from these appliance and showers with slightly less on simulated weekdays and slightly more on simulated weekends which were heavy wash/dry days. Most of these energy savings were due to the shower/GFX operation, and the least savings were for the dishwasher/GFX operation. Overall, the value of the 3000 W-h of displaced energy would have been $0.27/day based on an electricity price of $.09/kWh. Although small for today s convention house, these savings are significant for a home designed to approach maximum affordable efficiency where daily operating costs for the whole house are less than a dollar per day. In 2010 the actual measured cost of energy in one of the simulated occupancy houses which waste heat recovery testing was undertaken was $0.77/day.

Tomlinson, John J [ORNL; Christian, Jeff [Oak Ridge National Laboratory (ORNL); Gehl, Anthony C [ORNL

2012-09-01T23:59:59.000Z

11

About the Appliance and Equipment Standards Program | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

About the Appliance and About the Appliance and Equipment Standards Program About the Appliance and Equipment Standards Program The Department of Energy (DOE) and the Buildings Technologies Office sets minimum energy efficiency standards for approximately 50 categories of appliances and equipment used in homes, businesses, and other applications, as required by existing law. The appliances and equipment covered provide services that are used by consumers and businesses each day, such as space heating and cooling, refrigeration, cooking, clothes washing and drying, and lighting. DOE's minimum efficiency standards significantly reduce U.S. energy demand, lower emissions of greenhouse gases and other pollutants, and save consumers billions of dollars every year, without lessening the

12

Retrofit Integrated Space & Water Heating: Field Assessment, Minneapolis, Minnesota (Fact Sheet)  

SciTech Connect (OSTI)

This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water and forced air space heating. Called 'Combi' systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (EF of 0.60). Better insulation and tighter envelopes are reducing space heating loads for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent.

Not Available

2014-05-01T23:59:59.000Z

13

Federal Appliance Standards | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Federal Appliance Standards Federal Appliance Standards Federal Appliance Standards < Back Eligibility Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Manufacturing Water Heating Program Info Program Type Appliance/Equipment Efficiency Standards Provider U.S. Department of Energy '''''Note: HR 6582 of 2012 made some modifications to the efficiency standards previously adopted for some appliance types. The bill did not adopt new standards for previously unregulated appliances, but made some minor changes to the requirements for walk-in coolers, walk-in freezers, water heaters, self-contained medium temperature commercial refrigerators, central air conditioners, and heat pumps. The bill also included some

14

Passive Solar Space Heat | Open Energy Information  

Open Energy Info (EERE)

Passive Solar Space Heat Incentives Retrieved from "http:en.openei.orgwindex.php?titlePassiveSolarSpaceHeat&oldid26718...

15

Total Space Heat-  

Gasoline and Diesel Fuel Update (EIA)

Released: September, 2008 Released: September, 2008 Total Space Heat- ing Cool- ing Venti- lation Water Heat- ing Light- ing Cook- ing Refrig- eration Office Equip- ment Com- puters Other All Buildings* ........................... 3,037 115 397 384 52 1,143 22 354 64 148 357 Building Floorspace (Square Feet) 1,001 to 5,000 ........................... 386 19 43 18 11 93 7 137 8 12 38 5,001 to 10,000 .......................... 262 12 35 17 5 83 4 56 6 9 35 10,001 to 25,000 ........................ 407 20 46 44 8 151 3 53 9 19 54 25,001 to 50,000 ........................ 350 15 55 50 9 121 2 34 7 16 42 50,001 to 100,000 ...................... 405 16 57 65 7 158 2 29 6 18 45 100,001 to 200,000 .................... 483 16 62 80 5 195 1 24 Q 31 56 200,001 to 500,000 .................... 361 8 51 54 5 162 1 9 8 19 43 Over 500,000 ............................. 383 8 47 56 3 181 2 12 8 23 43 Principal Building Activity

16

Total Space Heat-  

Gasoline and Diesel Fuel Update (EIA)

Revised: December, 2008 Revised: December, 2008 Total Space Heat- ing Cool- ing Venti- lation Water Heat- ing Light- ing Cook- ing Refrig- eration Office Equip- ment Com- puters Other All Buildings ............................. 91.0 33.0 7.2 6.1 7.0 18.7 2.7 5.3 1.0 2.2 7.9 Building Floorspace (Square Feet) 1,001 to 5,000 ........................... 99.0 30.7 6.7 2.7 7.1 13.9 7.1 19.9 1.1 1.7 8.2 5,001 to 10,000 .......................... 80.0 30.1 5.5 2.6 6.1 13.6 5.2 8.2 0.8 1.4 6.6 10,001 to 25,000 ........................ 71.0 28.2 4.5 4.1 4.1 14.5 2.3 4.5 0.8 1.6 6.5 25,001 to 50,000 ........................ 79.0 29.9 6.8 5.9 6.3 14.9 1.7 3.9 0.8 1.8 7.1 50,001 to 100,000 ...................... 88.7 31.6 7.6 7.6 6.5 19.6 1.7 3.4 0.7 2.0 8.1 100,001 to 200,000 .................... 104.2 39.1 8.2 8.9 7.9 22.9 1.1 2.9 Q 3.2 8.7 200,001 to 500,000 ....................

17

Total Space Heat-  

Gasoline and Diesel Fuel Update (EIA)

Revised: December, 2008 Revised: December, 2008 Total Space Heat- ing Cool- ing Venti- lation Water Heat- ing Light- ing Cook- ing Refrig- eration Office Equip- ment Com- puters Other All Buildings ............................. 91.0 33.0 7.2 6.1 7.0 18.7 2.7 5.3 1.0 2.2 7.9 Building Floorspace (Square Feet) 1,001 to 5,000 ........................... 99.0 30.7 6.7 2.7 7.1 13.9 7.1 19.9 1.1 1.7 8.2 5,001 to 10,000 .......................... 80.0 30.1 5.5 2.6 6.1 13.6 5.2 8.2 0.8 1.4 6.6 10,001 to 25,000 ........................ 71.0 28.2 4.5 4.1 4.1 14.5 2.3 4.5 0.8 1.6 6.5 25,001 to 50,000 ........................ 79.0 29.9 6.8 5.9 6.3 14.9 1.7 3.9 0.8 1.8 7.1 50,001 to 100,000 ...................... 88.7 31.6 7.6 7.6 6.5 19.6 1.7 3.4 0.7 2.0 8.1 100,001 to 200,000 .................... 104.2 39.1 8.2 8.9 7.9 22.9 1.1 2.9 Q 3.2 8.7 200,001 to 500,000 ....................

18

Electric resistive space heating  

Science Journals Connector (OSTI)

The cost of heating residential buildings using electricity is compared to the cost employing gas or oil. (AIP)

David Bodansky

1985-01-01T23:59:59.000Z

19

Arnold Schwarzenegger 2010 APPLIANCE  

E-Print Network [OSTI]

.........................................................................................................................67 1603 Testing: All Appliances

20

Prospects of energy savings in residential space heating  

Science Journals Connector (OSTI)

This paper presents some insight to the problem of heating of housing in Jordan. Residential space and water heating are dependent particularly upon the combustion of fossil fuels, which thereby contribute significantly to air pollution and the build-up of carbon dioxide in the atmosphere. The results of a recent survey were used to evaluate the energy demand and conservation in Jordanian residential buildings. Space heating accounts for 61% of the total residential energy consumption with kerosene being the most popular fuel used, followed by liquefied petroleum gas (LPG), for heating purposes. Unvented combustion appliances employed to provide space heating produce high levels of combustion by-products that often exceed acceptable concentrations, degraded indoor air quality and cause unnecessary exposure to toxic gases such as carbon monoxide. During 1999, the number of accidents in households due to the use of different energy forms accounted for about 40% of all accidents, except road accidents, in Jordan. In light of the fact that only 5% of dwellings in Jordan have been provided with wall insulation and none employ roof insulation, the overall heat transfer coefficients, and consequently heating loads, were estimated for a typical single house using different constructions for external walls. It is concluded that space heating load can be reduced by about 50%, when economically-viable insulating measures are applied to the building envelopes, i.e. to ceilings and walls. These lead to corresponding reductions in fossil fuels consumption and in emissions of air pollutants.

Jamal O Jaber

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Appliances Research | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Emerging Technologies » Appliances Research Emerging Technologies » Appliances Research Appliances Research The Emerging Technology team conducts research into residential and commercial appliances. By partnering with industry, researchers, and other stakeholders, the Department of Energy acts as a catalyst in driving research in energy efficient technologies, with the goal of realizing 20% energy savings relative to a 2010 baseline. Appliance research focuses on refrigerators, washers, and dryers. Refrigerators Photo of a stainless steel refrigerator. Refrigerators have become substantially more energy efficient over the years, using less energy while also providing more space. While appliance standards for refrigerators have helped, continued research into new ways of improving refrigerators in the

22

Total Space Heating Water Heating Cook-  

Gasoline and Diesel Fuel Update (EIA)

Released: September, 2008 Released: September, 2008 Total Space Heating Water Heating Cook- ing Other Total Space Heating Water Heating Cook- ing Other All Buildings* ........................... 1,870 1,276 322 138 133 43.0 29.4 7.4 3.2 3.1 Building Floorspace (Square Feet) 1,001 to 5,000 ........................... 243 151 34 40 18 78.7 48.9 11.1 13.0 5.7 5,001 to 10,000 .......................... 202 139 31 29 Q 54.8 37.6 8.5 7.9 Q 10,001 to 25,000 ........................ 300 240 31 21 7 42.5 34.1 4.4 3.0 1.1 25,001 to 50,000 ........................ 250 182 40 11 Q 41.5 30.2 6.6 1.9 Q 50,001 to 100,000 ...................... 236 169 41 8 19 35.4 25.2 6.2 1.2 2.8 100,001 to 200,000 .................... 241 165 54 7 16 36.3 24.8 8.1 1.0 2.4 200,001 to 500,000 .................... 199 130 42 11 16 35.0 22.8 7.5 1.9 2.8 Over 500,000 ............................. 198

23

Total Space Heating Water Heating Cook-  

Gasoline and Diesel Fuel Update (EIA)

Released: September, 2008 Released: September, 2008 Total Space Heating Water Heating Cook- ing Other Total Space Heating Water Heating Cook- ing Other All Buildings ............................. 2,037 1,378 338 159 163 42.0 28.4 7.0 3.3 3.4 Building Floorspace (Square Feet) 1,001 to 5,000 ........................... 249 156 35 41 18 78.6 49.1 11.0 12.9 5.6 5,001 to 10,000 .......................... 218 147 32 31 7 54.8 37.1 8.1 7.9 1.7 10,001 to 25,000 ........................ 343 265 34 25 18 43.8 33.9 4.4 3.2 2.3 25,001 to 50,000 ........................ 270 196 41 13 Q 40.9 29.7 6.3 2.0 2.9 50,001 to 100,000 ...................... 269 186 45 13 24 35.8 24.8 6.0 1.8 3.2 100,001 to 200,000 .................... 267 182 56 10 19 35.4 24.1 7.4 1.3 2.6 200,001 to 500,000 .................... 204 134 43 11 17 34.7 22.7 7.3 1.8 2.9 Over 500,000 .............................

24

Solar space heating | Open Energy Information  

Open Energy Info (EERE)

heating heating Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of solar space heating technology.)[1] Contents 1 Space Heating 2 Passive Solar Space Heating 3 Active Solar Space Heating 4 References Space Heating A solar space-heating system can consist of a passive system, an active system, or a combination of both. Passive systems are typically less costly and less complex than active systems. However, when retrofitting a building, active systems might be the only option for obtaining solar energy. Passive Solar Space Heating Passive solar space heating takes advantage of warmth from the sun through design features, such as large south-facing windows, and materials in the floors or walls that absorb warmth during the day and release that warmth

25

Solar air heating system for combined DHW and space heating  

E-Print Network [OSTI]

Solar air heating system for combined DHW and space heating solar air collector PV-panel fannon-return valve DHW tank mantle cold waterhot water roof Solar Energy Centre Denmark Danish Technological Institute SEC-R-29 #12;Solar air heating system for combined DHW and space heating Søren ?stergaard Jensen

26

Water and Space Heating Heat Pumps  

E-Print Network [OSTI]

This paper discusses the design and operation of the Trane Weathertron III Heat Pump Water Heating System and includes a comparison of features and performance to other domestic water heating systems. Domestic water is generally provided through...

Kessler, A. F.

1985-01-01T23:59:59.000Z

27

Analysis of space heating and domestic hot water systems for energy-efficient residential buildings  

SciTech Connect (OSTI)

An analysis of the best ways of meeting the space heating and domestic hot water (DHW) needs of new energy-efficient houses with very low requirements for space heat is provided. The DHW load is about equal to the space heating load in such houses in northern climates. The equipment options which should be considered are discussed, including new equipment recently introduced in the market. It is concluded that the first consideration in selecting systems for energy-efficient houses should be identification of the air moving needs of the house for heat distribution, heat storage, ventilation, and ventilative cooling. This is followed, in order, by selection of the most appropriate distribution system, the heating appliances and controls, and the preferred energy source, gas, oil, or electricity.

Dennehy, G

1983-04-01T23:59:59.000Z

28

Solar space heating | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Solar space heating (Redirected from - Solar Ventilation Preheat) Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of solar space heating technology.)[1] Contents 1 Space Heating 2 Passive Solar Space Heating 3 Active Solar Space Heating 4 References Space Heating A solar space-heating system can consist of a passive system, an active system, or a combination of both. Passive systems are typically less costly and less complex than active systems. However, when retrofitting a building, active systems might be the only option for obtaining solar

29

Building Technologies Office: About the Appliance and Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

the Appliance and Equipment Standards Program the Appliance and Equipment Standards Program The Department of Energy (DOE) and the Buildings Technologies Office sets minimum energy efficiency standards for approximately 50 categories of appliances and equipment used in homes, businesses, and other applications, as required by existing law. The appliances and equipment covered provide services that are used by consumers and businesses each day, such as space heating and cooling, refrigeration, cooking, clothes washing and drying, and lighting. DOE's minimum efficiency standards significantly reduce U.S. energy demand, lower emissions of greenhouse gases and other pollutants, and save consumers billions of dollars every year, without lessening the vital services provided by these products. In addition, DOE implements laws designed to limit the water consumption of several plumbing products.

30

Heat pump system with selective space cooling  

DOE Patents [OSTI]

A reversible heat pump provides multiple heating and cooling modes and includes a compressor, an evaporator and heat exchanger all interconnected and charged with refrigerant fluid. The heat exchanger includes tanks connected in series to the water supply and a condenser feed line with heat transfer sections connected in counterflow relationship. The heat pump has an accumulator and suction line for the refrigerant fluid upstream of the compressor. Sub-cool transfer tubes associated with the accumulator/suction line reclaim a portion of the heat from the heat exchanger. A reversing valve switches between heating/cooling modes. A first bypass is operative to direct the refrigerant fluid around the sub-cool transfer tubes in the space cooling only mode and during which an expansion valve is utilized upstream of the evaporator/indoor coil. A second bypass is provided around the expansion valve. A programmable microprocessor activates the first bypass in the cooling only mode and deactivates the second bypass, and vice-versa in the multiple heating modes for said heat exchanger. In the heating modes, the evaporator may include an auxiliary outdoor coil for direct supplemental heat dissipation into ambient air. In the multiple heating modes, the condensed refrigerant fluid is regulated by a flow control valve. 4 figs.

Pendergrass, J.C.

1997-05-13T23:59:59.000Z

31

Heat pump system with selective space cooling  

DOE Patents [OSTI]

A reversible heat pump provides multiple heating and cooling modes and includes a compressor, an evaporator and heat exchanger all interconnected and charged with refrigerant fluid. The heat exchanger includes tanks connected in series to the water supply and a condenser feed line with heat transfer sections connected in counterflow relationship. The heat pump has an accumulator and suction line for the refrigerant fluid upstream of the compressor. Sub-cool transfer tubes associated with the accumulator/suction line reclaim a portion of the heat from the heat exchanger. A reversing valve switches between heating/cooling modes. A first bypass is operative to direct the refrigerant fluid around the sub-cool transfer tubes in the space cooling only mode and during which an expansion valve is utilized upstream of the evaporator/indoor coil. A second bypass is provided around the expansion valve. A programmable microprocessor activates the first bypass in the cooling only mode and deactivates the second bypass, and vice-versa in the multiple heating modes for said heat exchanger. In the heating modes, the evaporator may include an auxiliary outdoor coil for direct supplemental heat dissipation into ambient air. In the multiple heating modes, the condensed refrigerant fluid is regulated by a flow control valve.

Pendergrass, Joseph C. (Gainesville, GA)

1997-01-01T23:59:59.000Z

32

Combustion Safety for Appliances Using Indoor Air (Fact Sheet)  

SciTech Connect (OSTI)

This measure guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate measure guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

Not Available

2014-05-01T23:59:59.000Z

33

Evaluation and demonstration of decentralized space and water heating versus centralized services for new and rehabilitated multifamily buildings. Final report  

SciTech Connect (OSTI)

The general objective of this research was aimed at developing sufficient technical and economic know-how to convince the building and design communities of the appropriateness and energy advantages of decentralized space and water heating for multifamily buildings. Two main goals were established to guide this research. First, the research sought to determine the cost-benefit advantages of decentralized space and water heating versus centralized systems for multifamily applications based on innovative gas piping and appliance technologies. The second goal was to ensure that this information is made available to the design community.

Belkus, P. [Foster-Miller, Inc., Waltham, MA (US); Tuluca, A. [Steven Winter Associates, Inc., Norwalk, CT (US)

1993-06-01T23:59:59.000Z

34

Jackson Hot Springs Lodge Space Heating Low Temperature Geothermal...  

Open Energy Info (EERE)

Hot Springs Lodge Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Jackson Hot Springs Lodge Space Heating Low Temperature Geothermal Facility...

35

Passive Solar Building Design and Solar Thermal Space Heating...  

Broader source: Energy.gov (indexed) [DOE]

Passive Solar Building Design and Solar Thermal Space Heating Webinar Passive Solar Building Design and Solar Thermal Space Heating Webinar Watch a recording of National Renewable...

36

List of Solar Space Heat Incentives | Open Energy Information  

Open Energy Info (EERE)

Space Heat Incentives Space Heat Incentives Jump to: navigation, search The following contains the list of 499 Solar Space Heat Incentives. CSV (rows 1 - 499) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active 30% Business Tax Credit for Solar (Vermont) Corporate Tax Credit Vermont Commercial Industrial Photovoltaics Solar Space Heat Solar Thermal Electric Solar Thermal Process Heat Solar Water Heat No APS - Renewable Energy Incentive Program (Arizona) Utility Rebate Program Arizona Commercial Residential Anaerobic Digestion Biomass Daylighting Geothermal Electric Ground Source Heat Pumps Landfill Gas Other Distributed Generation Technologies Photovoltaics Small Hydroelectric Solar Pool Heating Solar Space Heat Solar Thermal Process Heat Solar Water Heat

37

Reading Municipal Light Department - Residential ENERGY STAR Appliance  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Reading Municipal Light Department - Residential ENERGY STAR Appliance Rebate Program Reading Municipal Light Department - Residential ENERGY STAR Appliance Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Heat Pumps Water Heating Maximum Rebate One rebate per Energy Star appliance or two rebates on the purchase of programmable thermostats Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Electric Heat Pump Water Heater: $250 Air Source Heat Pump: $100 Central AC: $100 Refrigerator: $50 Washing Machine: $50 Dishwasher: $50 Room A/C: $25 Dehumidifier: $25 Programmable Thermostat:$15 (limit 2) Ceiling Fan: $10

38

List of Passive Solar Space Heat Incentives | Open Energy Information  

Open Energy Info (EERE)

Space Heat Incentives Space Heat Incentives Jump to: navigation, search The following contains the list of 278 Passive Solar Space Heat Incentives. CSV (rows 1 - 278) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Alternative Energy and Energy Conservation Patent Exemption (Corporate) (Massachusetts) Industry Recruitment/Support Massachusetts Commercial Biomass Fuel Cells Geothermal Electric Ground Source Heat Pumps Hydroelectric energy Municipal Solid Waste Passive Solar Space Heat Photovoltaics Solar Space Heat Solar Thermal Electric Solar Thermal Process Heat Solar Water Heat Wind energy Yes Alternative Energy and Energy Conservation Patent Exemption (Personal) (Massachusetts) Industry Recruitment/Support Massachusetts General Public/Consumer Biomass

39

BIODIESEL BLENDS IN SPACE HEATING EQUIPMENT.  

SciTech Connect (OSTI)

Biodiesel is a diesel-like fuel that is derived from processing vegetable oils from various sources, such as soy oil, rapeseed or canola oil, and also waste vegetable oils resulting from cooking use. Brookhaven National laboratory initiated an evaluation of the performance of blends of biodiesel and home heating oil in space heating applications under the sponsorship of the Department of Energy (DOE) through the National Renewable Energy Laboratory (NREL). This report is a result of this work performed in the laboratory. A number of blends of varying amounts of a biodiesel in home heating fuel were tested in both a residential heating system and a commercial size boiler. The results demonstrate that blends of biodiesel and heating oil can be used with few or no modifications to the equipment or operating practices in space heating. The results also showed that there were environmental benefits from the biodiesel addition in terms of reductions in smoke and in Nitrogen Oxides (NOx). The latter result was particularly surprising and of course welcome, in view of the previous results in diesel engines where no changes had been seen. Residential size combustion equipment is presently not subject to NOx regulation. If reductions in NOx similar to those observed here hold up in larger size (commercial and industrial) boilers, a significant increase in the use of biodiesel-like fuel blends could become possible.

KRISHNA,C.R.

2001-12-01T23:59:59.000Z

40

Heat kernels on metric measure spaces Alexander Grigor'yan  

E-Print Network [OSTI]

Heat kernels on metric measure spaces Alexander Grigor'yan Department of Mathematics University Kong April 2013 Contents 1 What is the heat kernel 2 1.1 Examples of heat kernels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.2 Heat kernel in Euclidean spaces . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.2.1 Heat

Grigor'yan, Alexander

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Next Generation Appliances R&D Roadmap  

Broader source: Energy.gov [DOE]

Appliances present an attractive opportunity for near-term energy savings in existing building, because they are less expensive and replaced more regularly than heating, ventilation, and air-conditioning (HVAC) systems or building envelope components.

42

Questar Gas - Home Builder Gas Appliance Rebate Program (Idaho) |  

Broader source: Energy.gov (indexed) [DOE]

Questar Gas - Home Builder Gas Appliance Rebate Program (Idaho) Questar Gas - Home Builder Gas Appliance Rebate Program (Idaho) Questar Gas - Home Builder Gas Appliance Rebate Program (Idaho) < Back Eligibility Construction Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Construction Commercial Weatherization Design & Remodeling Appliances & Electronics Water Heating Windows, Doors, & Skylights Program Info State Idaho Program Type Utility Rebate Program Rebate Amount New Construction Home Options Builder Option Package 1: $50 (single family), $50 (multifamily) Builder Option Package 2: $100 (single family), $100 (multifamily) Energy Star 3.0: $300 (single family), $200 (multifamily) High Performance Home: $500 (single family), $300 (multifamily)

43

Retrospective Evaluation of Appliance Price Trends  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Evaluation of Appliance Price Trends Evaluation of Appliance Price Trends Title Retrospective Evaluation of Appliance Price Trends Publication Type Journal Article Year of Publication 2009 Authors Dale, Larry L., Camille Antinori, Michael A. McNeil, James E. McMahon, and Sydny K. Fujita Journal Energy Policy Volume 37 Issue 2 Pagination 597-605 Date Published November 20 Keywords appliance efficiency standards, price forecasts, EES-EG Abstract Real prices of major appliances (refrigerators, dishwashers, heating and cooling equipment) have been falling since the late 1970s despite increases in appliance efficiency and other quality variables. This paper demonstrates that historic increases in efficiency over time, including those resulting from minimum efficiency standards, incur smaller price increases than were expected by the Department of Energy (DOE) forecasts made in conjunction with standards. This effect can be explained by technological innovation, which lowers the cost of efficiency, and by market changes contributing to lower markups and economies of scale in production of higher efficiency units. We reach four principal conclusions about appliance trends and retail price setting:1. For the past several decades, the retail price of appliances has been steadily falling while efficiency has been increasing.2. Past retail price predictions made by the DOE analyses of efficiency standards, assuming constant prices over time, have tended to overestimate retail prices.3. The average incremental price to increase appliance efficiency has declined over time. DOE technical support documents have typically overestimated this incremental price and retail prices.4. Changes in retail markups and economies of scale in production of more efficient appliances may have contributed to declines in prices of efficient appliances.

44

Roaring Fork Valley - Energy Efficient Appliance Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

Efficient Appliance Program Efficient Appliance Program Roaring Fork Valley - Energy Efficient Appliance Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Appliances & Electronics Maximum Rebate Smart Strip: $30 Programmable Thermostats: $50 Program Info State Colorado Program Type Local Rebate Program Rebate Amount Furnaces (AFUE 92% or higher): $300 Boilers (AFUE 92% or higher): $500 Dishwashers: $100 Clothes Washers: $75 Refrigerators: $100 Smart Strip: $15 Programmable thermostats: $15 Provider Community Office for Resource Efficiency (CORE) The Aspen Community Office for Resource Efficiency (CORE) promotes renewable energy, energy efficiency and green building techniques in western Colorado's Roaring Fork Valley. For customers who install energy

45

The Heat Equation (One Space Dimension) In these notes we derive the heat equation for one space dimension. This partial  

E-Print Network [OSTI]

The Heat Equation (One Space Dimension) In these notes we derive the heat equation for one space dimension. This partial differential equation describes the flow of heat energy, and consequently the behaviour of the temperature, in an idealized long thin rod, under the assumptions that heat energy neither

Feldman, Joel

46

Reminder: Personal Appliance Use at Jefferson Lab | Jefferson...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The Lab provides refrigerators, microwave ovens, and coffee makers in common use space of buildings. Personal household appliances are not authorized. For your reference, a copy of...

47

Heat kernels on metric measure spaces A.Grigor'yan  

E-Print Network [OSTI]

Heat kernels on metric measure spaces A.Grigor'yan Lectures at Cornell Probability Summer School, July 2010 #12;2 #12;Contents 1 The notion of the heat kernel 5 1.1 Examples of heat kernels . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.1.1 Heat kernel in Rn . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.1.2 Heat kernels

Grigor'yan, Alexander

48

Incorporating Experience Curves in Appliance Standards Analysis  

E-Print Network [OSTI]

trade associations such as AHAM, GAMA, AHRI, and ApplianceAppliance Manufacturers (AHAM), Gas Appliance Manufacturersas Appliance Magazine and the AHAM Fact Book. In most cases,

Desroches, Louis-Benoit

2012-01-01T23:59:59.000Z

49

Measure Guideline: Combustion Safety for Natural Draft Appliances Using Indoor Air  

SciTech Connect (OSTI)

This measure guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate measure guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

Brand, L.

2014-04-01T23:59:59.000Z

50

Solar Space Heating with Air and Liquid Systems  

Science Journals Connector (OSTI)

...several thousand solar space heating systems...can be supplied by solar energy delivered from flat-plate...liquid collection and storage systems, demand...Annual costs of solar heating equipment...current values of energy savings, but fuel...

1980-01-01T23:59:59.000Z

51

Hydrogen Generator Appliance  

Broader source: Energy.gov (indexed) [DOE]

lAbOrAtOry NG Workshop summary report - appeNDIX J slide presentation: hydrogen Generator appliance Gus Block, Nuvera Fuel Cells...

52

Appliance Standards Resources  

Broader source: Energy.gov [DOE]

The federal government, and some states, have established minimum efficiency standards for certain appliances and equipment, such as refrigerators and clothes washers.

53

Residential appliances technology atlas  

SciTech Connect (OSTI)

Residential appliance technology and efficiency opportunities for refrigerators and freezers, cooking appliances, clothes washers and dryers, dishwashers, and some often-ignored household devices such as spas, pool pumps, waterbed heaters, televisions, and home computers are thoroughly covered in this Atlas. The US appliance market, fuel shares, efficiency standards, labeling, and advances in home automation, design for recycling, and CFC issues are also discussed. The resource section contains lists of appliance manufacturers and distributors, and trade, professional, and governmental organizations, a summary of key resources for further information, and an index.

NONE

1994-12-31T23:59:59.000Z

54

Tips: Kitchen Appliances | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tips: Kitchen Appliances Tips: Kitchen Appliances Tips: Kitchen Appliances April 24, 2012 - 8:34pm Addthis ENERGY STAR® Refrigerators Are Cool! ENERGY STAR-qualified refrigerators are 20% more energy efficient than non-qualified models. Models with top-mounted freezers use 10-25% less energy than side-by-side or bottom-mount units. ENERGY STAR® Refrigerators Are Cool! ENERGY STAR-qualified refrigerators are 20% more energy efficient than non-qualified models. Models with top-mounted freezers use 10-25% less energy than side-by-side or bottom-mount units. You can save energy in your kitchen through more efficient use of your dishwasher, refrigerator and freezer, and other common appliances. Dishwashers Most of the energy used by a dishwasher is for water heating.

55

APPLIANCE EFFICIENCY REGULATIONS FOR REFRIGERATORS AND FREEZERS  

E-Print Network [OSTI]

mobile equipment. (c) Central air conditioning heat pumps, regardless of capacity, except that requirements for central air conditioning heat pumps with cooling capacity of 135,000 Btu per hour or more#12;#12;APPLIANCE EFFICIENCY REGULATIONS FOR REFRIGERATORS AND FREEZERS ROOM AIR CONDITIONERS

56

Space Heating & Cooling Research | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Space Heating & Cooling Research Space Heating & Cooling Research Space Heating & Cooling Research The Emerging Technology team conducts research in space heating and cooling technologies, with a goal of realizing aggregate energy savings of 20% relative to a 2010 baseline. In addition to work involving the development of products, the U.S. Department of Energy (DOE), along with industry partners and researchers, develops best practices, tests, and guides designed to reduce market barriers and increase public awareness of these energy saving technologies. Research is currently focusing on: Geothermal Heat Pumps Photo of a home with a geothermal heat pump, showing how it can regulate the temperature of a home using the temperature underground to cool warm air or heat cold air.

57

Appliance Efficiency Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

6 6 Appliance Efficiency Standards Part 2 of 2: Policy process and consumer gains Part 1 of this article (CBS News, Spring 1995) discussed LBNL's role in setting federal appliance efficiency standards and presented an overview of the net national benefits of standards. Here, we examine the broader policy context for appliance standards and consumer benefits. Policy Context Appliance efficiency standards provide a minimum requirement for energy efficiency at the point of manufacture (or import). These standards seek to overcome market failures-including price distortions and transaction costs-that have historically given rise to a gap between observed and attainable product efficiencies. In this way, appliance standards complement information programs, utility DSM and other incentive programs,

58

Space Heating and Cooling Products and Services | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Space Heating and Cooling Products and Services Space Heating and Cooling Products and Services Space Heating and Cooling Products and Services June 24, 2012 - 2:50pm Addthis Get tips on heating and cooling product information and services. | Photo courtesy of Flickr user ActiveSteve. Get tips on heating and cooling product information and services. | Photo courtesy of Flickr user ActiveSteve. Use the following links to get product information and locate professional services for space heating and cooling. Product Information Boilers ENERGY STAR® Information on the benefits of ENERGY STAR boilers, as well as resources to calculate savings and find products. Ceiling Fans ENERGY STAR® Describes the benefits of choosing ENERGY STAR ceiling fans, as well as

59

Space Heating and Cooling Products and Services | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Space Heating and Cooling Products and Services Space Heating and Cooling Products and Services Space Heating and Cooling Products and Services June 24, 2012 - 2:50pm Addthis Get tips on heating and cooling product information and services. | Photo courtesy of Flickr user ActiveSteve. Get tips on heating and cooling product information and services. | Photo courtesy of Flickr user ActiveSteve. Use the following links to get product information and locate professional services for space heating and cooling. Product Information Boilers ENERGY STAR® Information on the benefits of ENERGY STAR boilers, as well as resources to calculate savings and find products. Ceiling Fans ENERGY STAR® Describes the benefits of choosing ENERGY STAR ceiling fans, as well as

60

Space Heating and Cooling Products and Services | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Space Heating and Cooling Products and Services Space Heating and Cooling Products and Services Space Heating and Cooling Products and Services June 24, 2012 - 2:50pm Addthis Get tips on heating and cooling product information and services. | Photo courtesy of Flickr user ActiveSteve. Get tips on heating and cooling product information and services. | Photo courtesy of Flickr user ActiveSteve. Use the following links to get product information and locate professional services for space heating and cooling. Product Information Boilers ENERGY STAR® Information on the benefits of ENERGY STAR boilers, as well as resources to calculate savings and find products. Ceiling Fans ENERGY STAR® Describes the benefits of choosing ENERGY STAR ceiling fans, as well as

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Efficiency Maine Residential Appliance Program (Maine) | Department of  

Broader source: Energy.gov (indexed) [DOE]

Appliance Program (Maine) Appliance Program (Maine) Efficiency Maine Residential Appliance Program (Maine) < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Water Heating Program Info Funding Source Efficiency Maine Start Date 10/01/2012 Expiration Date 06/30/2014 State Maine Program Type State Rebate Program Rebate Amount Ductless Heat Pumps: $500 Heat pump water heaters: $300 Provider Efficiency Maine Efficiency Maine offers rebates for the purchase of Energy Star certified water heaters, and ductless heat pumps. Purchases must be made between September 1, 2013 and June 30, 2014. See the program web site for the mail-in rebate forms and to locate a participating retailer. In addition, in partnership with Maine Libraries, Efficiency Maine has made

62

Energy Efficient, Summer-Friendly Appliances | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Energy Efficient, Summer-Friendly Appliances Energy Efficient, Summer-Friendly Appliances Energy Efficient, Summer-Friendly Appliances June 2, 2009 - 1:43pm Addthis Elizabeth Spencer Communicator, National Renewable Energy Laboratory Last week's question of the week included a little reference to the No-Cost and Low-Cost Tips to Save Energy this Summer. So I thought I'd follow that up with some, well, not-so-low-cost tips that you can consider this summer: Purchasing summertime, energy-friendly appliances. If you're looking to replace any major cooling appliances this summer, you might want to look into Energy Saver's information on cooling systems-and especially the section on selecting and replacing heating and cooling systems. That'll help you know what questions to ask before you start looking. And once you're ready to go out and start looking at appliances, you might

63

Low-Cost Gas Heat Pump For Building Space Heating | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Space Heating Lead Performer: Stone Mountain Technologies - Erwin, TN Partners: -- A.O. Smith - Milwaukee, WI -- Gas Technology Institute - Des Plaines, IL DOE Funding: 903,000...

64

Sales Tax Holiday for Energy-Efficient Appliances | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Sales Tax Holiday for Energy-Efficient Appliances Sales Tax Holiday for Energy-Efficient Appliances Sales Tax Holiday for Energy-Efficient Appliances < Back Eligibility General Public/Consumer Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heating Water Heating Maximum Rebate None, but sale price limited to $1,500 per appliance Program Info Start Date 08/28/2008 State Missouri Program Type Sales Tax Incentive Rebate Amount 100% sales tax exemption Provider Missouri Department of Revenue The state of Missouri offers consumers a seven-day ''exemption from state sales taxes'' on certain Energy Star certified new appliances. The state sales tax holiday, known as the "Show-Me Green Sales Tax Holiday", applies to Energy Star certified appliances up to $1,500 in price intended for

65

River Falls Municipal Utilities - Energy Star Appliance Rebates |  

Broader source: Energy.gov (indexed) [DOE]

River Falls Municipal Utilities - Energy Star Appliance Rebates River Falls Municipal Utilities - Energy Star Appliance Rebates River Falls Municipal Utilities - Energy Star Appliance Rebates < Back Eligibility Low-Income Residential Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Cooling Construction Design & Remodeling Sealing Your Home Ventilation Heat Pumps Appliances & Electronics Commercial Lighting Lighting Water Heating Other Program Info Start Date 05/01/2010 Expiration Date 12/31/12 State Wisconsin Program Type Utility Rebate Program Rebate Amount Tree Planting: 50% of cost up to $50 (limit 3 trees) Freezer Recycling: $30 Refrigerator Recycling: $30 Energy Star Home Performance: 33.3% up to $1,500 15% Energy Savings from Installed Measures: $200

66

Barron Electric Cooperative - Energy Star Appliance and Energy Efficient  

Broader source: Energy.gov (indexed) [DOE]

Barron Electric Cooperative - Energy Star Appliance and Energy Barron Electric Cooperative - Energy Star Appliance and Energy Efficient Lighting Rebate Program Barron Electric Cooperative - Energy Star Appliance and Energy Efficient Lighting Rebate Program < Back Eligibility Agricultural Commercial Multi-Family Residential Nonprofit Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Wisconsin Program Type Utility Rebate Program Rebate Amount Clothes Washer: $25 Dishwasher: $25 Dehumidifier: $25 Refrigerator: $25 Room A/C: $25 Refrigerator or Freezer Recycling: up to $25 Room A/C Unit Recycling: up to $25 Central A/C: $40 - $80/ton Air-Source Heat Pump: $150/ton Geothermal Heat Pump: $300/ton Commercial A/C: $40/ton

67

Burgdorf Hot Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Facility Burgdorf Hot Springs Sector Geothermal energy Type Space Heating Location Burgdorf, Idaho Coordinates Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

68

Buildings","All Buildings with Space Heating","Space-Heating Energy Sources Used  

U.S. Energy Information Administration (EIA) Indexed Site

0. Space-Heating Energy Sources, Number of Buildings, 1999" 0. Space-Heating Energy Sources, Number of Buildings, 1999" ,"Number of Buildings (thousand)" ,"All Buildings","All Buildings with Space Heating","Space-Heating Energy Sources Used (more than one may apply)" ,,,"Electricity","Natural Gas","Fuel Oil","District Heat","Propane","Othera" "All Buildings ................",4657,4016,1880,2380,377,96,307,94 "Building Floorspace" "(Square Feet)" "1,001 to 5,000 ...............",2348,1982,926,1082,214,"Q",162,"Q" "5,001 to 10,000 ..............",1110,946,379,624,73,"Q",88,"Q" "10,001 to 25,000 .............",708,629,324,389,52,19,42,"Q"

69

Retrospective Evaluation of Appliance Price Trends  

E-Print Network [OSTI]

Home Appliance Manufacturers (AHAM), 19782001 AssociationHome Appliance Manufacturers (AHAM), 19782001. Directory ofAppliance Manufacturers (AHAM) certified directory where

Dale, Larry

2010-01-01T23:59:59.000Z

70

Maywood Industries of Oregon Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Maywood Industries of Oregon Space Heating Low Temperature Geothermal Maywood Industries of Oregon Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Maywood Industries of Oregon Space Heating Low Temperature Geothermal Facility Facility Maywood Industries of Oregon Sector Geothermal energy Type Space Heating Location Klamath Falls, Oregon Coordinates 42.224867°, -121.7816704° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

71

Bozeman Hot Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Bozeman Hot Springs Space Heating Low Temperature Geothermal Facility Bozeman Hot Springs Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Bozeman Hot Springs Space Heating Low Temperature Geothermal Facility Facility Bozeman Hot Springs Sector Geothermal energy Type Space Heating Location Bozeman, Montana Coordinates 45.68346°, -111.050499° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

72

Radium Hot Springs Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Radium Hot Springs Space Heating Low Temperature Geothermal Facility Radium Hot Springs Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Radium Hot Springs Space Heating Low Temperature Geothermal Facility Facility Radium Hot Springs Sector Geothermal energy Type Space Heating Location Union County, Oregon Coordinates 45.2334122°, -118.0410627° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

73

Cedarville Elementary & High School Space Heating Low Temperature  

Open Energy Info (EERE)

Cedarville Elementary & High School Space Heating Low Temperature Cedarville Elementary & High School Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Cedarville Elementary & High School Space Heating Low Temperature Geothermal Facility Facility Cedarville Elementary & High School Sector Geothermal energy Type Space Heating Location Cedarville, California Coordinates 41.5290606°, -120.1732781° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

74

Miracle Hot Spring Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Miracle Hot Spring Space Heating Low Temperature Geothermal Facility Miracle Hot Spring Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Miracle Hot Spring Space Heating Low Temperature Geothermal Facility Facility Miracle Hot Spring Sector Geothermal energy Type Space Heating Location Bakersfield, California Coordinates 35.3732921°, -119.0187125° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

75

Hot Springs National Park Space Heating Low Temperature Geothermal Facility  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Hot Springs National Park Space Heating Low Temperature Geothermal Facility Facility Hot Springs National Park Sector Geothermal energy Type Space Heating Location Hot Springs, Arkansas Coordinates 34.5037004°, -93.0551795° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

76

Lolo Hot Springs Resort Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Lolo Hot Springs Resort Space Heating Low Temperature Geothermal Facility Lolo Hot Springs Resort Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Lolo Hot Springs Resort Space Heating Low Temperature Geothermal Facility Facility Lolo Hot Springs Resort Sector Geothermal energy Type Space Heating Location Missoula County, Montana Coordinates 47.0240503°, -113.6869923° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

77

Klamath Schools (7) Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Schools (7) Space Heating Low Temperature Geothermal Facility Schools (7) Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Klamath Schools (7) Space Heating Low Temperature Geothermal Facility Facility Klamath Schools (7) Sector Geothermal energy Type Space Heating Location Klamath Falls, Oregon Coordinates 42.224867°, -121.7816704° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

78

Shoshone Motel & Trailer Park Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Shoshone Motel & Trailer Park Space Heating Low Temperature Geothermal Shoshone Motel & Trailer Park Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Shoshone Motel & Trailer Park Space Heating Low Temperature Geothermal Facility Facility Shoshone Motel & Trailer Park Sector Geothermal energy Type Space Heating Location Death Valley, California Coordinates Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

79

Olene Gap Space Heating Low Temperature Geothermal Facility | Open Energy  

Open Energy Info (EERE)

Olene Gap Space Heating Low Temperature Geothermal Facility Olene Gap Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Olene Gap Space Heating Low Temperature Geothermal Facility Facility Olene Gap Sector Geothermal energy Type Space Heating Location Klamath County, Oregon Coordinates 42.6952767°, -121.6142133° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

80

Surprise Valley Hospital Space Heating Low Temperature Geothermal Facility  

Open Energy Info (EERE)

Hospital Space Heating Low Temperature Geothermal Facility Hospital Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Surprise Valley Hospital Space Heating Low Temperature Geothermal Facility Facility Surprise Valley Hospital Sector Geothermal energy Type Space Heating Location Cedarville, California Coordinates 41.5290606°, -120.1732781° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Wiesbaden Motel & Health Resort Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Wiesbaden Motel & Health Resort Space Heating Low Temperature Geothermal Wiesbaden Motel & Health Resort Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Wiesbaden Motel & Health Resort Space Heating Low Temperature Geothermal Facility Facility Wiesbaden Motel & Health Resort Sector Geothermal energy Type Space Heating Location Ouray, Colorado Coordinates 38.0227716°, -107.6714487° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

82

Marlin Hospital Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Marlin Hospital Space Heating Low Temperature Geothermal Facility Marlin Hospital Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Marlin Hospital Space Heating Low Temperature Geothermal Facility Facility Marlin Hospital Sector Geothermal energy Type Space Heating Location Marlin, Texas Coordinates 31.3062874°, -96.8980439° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

83

White Sulphur Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Sulphur Springs Space Heating Low Temperature Geothermal Facility Sulphur Springs Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name White Sulphur Springs Space Heating Low Temperature Geothermal Facility Facility White Sulphur Springs Sector Geothermal energy Type Space Heating Location White Sulphur Springs, Montana Coordinates 46.548277°, -110.9021561° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

84

Hillbrook Nursing Home Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Hillbrook Nursing Home Space Heating Low Temperature Geothermal Facility Hillbrook Nursing Home Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Hillbrook Nursing Home Space Heating Low Temperature Geothermal Facility Facility Hillbrook Nursing Home Sector Geothermal energy Type Space Heating Location Clancy, Montana Coordinates 46.4652096°, -111.9863826° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

85

Miracle Hot Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Miracle Hot Springs Space Heating Low Temperature Geothermal Facility Facility Miracle Hot Springs Sector Geothermal energy Type Space Heating Location Buhl, Idaho Coordinates 42.5990714°, -114.7594946° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

86

LDS Wardhouse Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

LDS Wardhouse Space Heating Low Temperature Geothermal Facility LDS Wardhouse Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name LDS Wardhouse Space Heating Low Temperature Geothermal Facility Facility LDS Wardhouse Sector Geothermal energy Type Space Heating Location Newcastle, Utah Coordinates 37.6666413°, -113.549406° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

87

LDS Church Space Heating Low Temperature Geothermal Facility | Open Energy  

Open Energy Info (EERE)

LDS Church Space Heating Low Temperature Geothermal Facility LDS Church Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name LDS Church Space Heating Low Temperature Geothermal Facility Facility LDS Church Sector Geothermal energy Type Space Heating Location Almo, Idaho Coordinates 42.1001924°, -113.6336192° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

88

The Wilderness Lodge Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

The Wilderness Lodge Space Heating Low Temperature Geothermal Facility The Wilderness Lodge Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name The Wilderness Lodge Space Heating Low Temperature Geothermal Facility Facility The Wilderness Lodge Sector Geothermal energy Type Space Heating Location Gila Hot Springs, New Mexico Coordinates Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

89

Senior Citizens' Center Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Senior Citizens' Center Space Heating Low Temperature Geothermal Facility Senior Citizens' Center Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Senior Citizens' Center Space Heating Low Temperature Geothermal Facility Facility Senior Citizens' Center Sector Geothermal energy Type Space Heating Location Truth or Consequences, New Mexico Coordinates 33.1284047°, -107.2528069° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

90

Schutz's Hot Spring Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Schutz's Hot Spring Space Heating Low Temperature Geothermal Facility Schutz's Hot Spring Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Schutz's Hot Spring Space Heating Low Temperature Geothermal Facility Facility Schutz's Hot Spring Sector Geothermal energy Type Space Heating Location Crouch, Idaho Coordinates 44.1151717°, -115.970954° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

91

Mount Princeton Area Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Area Space Heating Low Temperature Geothermal Facility Area Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Mount Princeton Area Space Heating Low Temperature Geothermal Facility Facility Mount Princeton Area Sector Geothermal energy Type Space Heating Location Mount Princeton, Colorado Coordinates 38.749167°, -106.2425° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

92

Baranof Space Heating Low Temperature Geothermal Facility | Open Energy  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Baranof Space Heating Low Temperature Geothermal Facility Facility Baranof Sector Geothermal energy Type Space Heating Location Sitka, Alaska Coordinates 57.0530556°, -135.33° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

93

Warm Springs State Hospital Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

State Hospital Space Heating Low Temperature Geothermal State Hospital Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Warm Springs State Hospital Space Heating Low Temperature Geothermal Facility Facility Warm Springs State Hospital Sector Geothermal energy Type Space Heating Location Warm Springs, Montana Coordinates 46.1813145°, -112.78476° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

94

Vale Residences Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Residences Space Heating Low Temperature Geothermal Facility Residences Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Vale Residences Space Heating Low Temperature Geothermal Facility Facility Vale Residences Sector Geothermal energy Type Space Heating Location Vale, Oregon Coordinates 43.9821055°, -117.2382311° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

95

Cotulla High School Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Cotulla High School Space Heating Low Temperature Geothermal Facility Cotulla High School Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Cotulla High School Space Heating Low Temperature Geothermal Facility Facility Cotulla High School Sector Geothermal energy Type Space Heating Location Cotulla, Texas Coordinates 28.436934°, -99.2350322° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

96

Melozi Space Heating Low Temperature Geothermal Facility | Open Energy  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Melozi Space Heating Low Temperature Geothermal Facility Facility Melozi Sector Geothermal energy Type Space Heating Location Yukon, Alaska Coordinates Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

97

Indian Valley Hospital Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Valley Hospital Space Heating Low Temperature Geothermal Facility Valley Hospital Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Indian Valley Hospital Space Heating Low Temperature Geothermal Facility Facility Indian Valley Hospital Sector Geothermal energy Type Space Heating Location Greenville, California Coordinates 40.1396126°, -120.9510675° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

98

Lakeview Residences Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Lakeview Residences Space Heating Low Temperature Geothermal Facility Lakeview Residences Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Lakeview Residences Space Heating Low Temperature Geothermal Facility Facility Lakeview Residences Sector Geothermal energy Type Space Heating Location Lakeview, Oregon Coordinates 42.1887721°, -120.345792° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

99

Boulder Hot Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Boulder Hot Springs Space Heating Low Temperature Geothermal Facility Facility Boulder Hot Springs Sector Geothermal energy Type Space Heating Location Boulder, Montana Coordinates 46.2365947°, -112.1208336° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

100

Langel Valley Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Langel Valley Space Heating Low Temperature Geothermal Facility Langel Valley Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Langel Valley Space Heating Low Temperature Geothermal Facility Facility Langel Valley Sector Geothermal energy Type Space Heating Location Bonanza, Oregon Coordinates 42.1987607°, -121.4061076° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Henley High School Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Henley High School Space Heating Low Temperature Geothermal Facility Henley High School Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Henley High School Space Heating Low Temperature Geothermal Facility Facility Henley High School Sector Geothermal energy Type Space Heating Location Klamath Falls, Oregon Coordinates 42.224867°, -121.7816704° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

102

Broadwater Athletic Club & Hot Springs Space Heating Low Temperature  

Open Energy Info (EERE)

Athletic Club & Hot Springs Space Heating Low Temperature Athletic Club & Hot Springs Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Broadwater Athletic Club & Hot Springs Space Heating Low Temperature Geothermal Facility Facility Broadwater Athletic Club & Hot Springs Sector Geothermal energy Type Space Heating Location Helena, Montana Coordinates 46.6002123°, -112.0147188° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

103

Homestead Resort Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Resort Space Heating Low Temperature Geothermal Facility Resort Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Homestead Resort Space Heating Low Temperature Geothermal Facility Facility Homestead Resort Sector Geothermal energy Type Space Heating Location Hot Springs, Virginia Coordinates Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

104

Cottonwood Hot Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Cottonwood Hot Springs Space Heating Low Temperature Geothermal Facility Facility Cottonwood Hot Springs Sector Geothermal energy Type Space Heating Location Buena Vista, Colorado Coordinates 38.8422178°, -106.1311288° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

105

Jackson Hot Springs Lodge Space Heating Low Temperature Geothermal Facility  

Open Energy Info (EERE)

Hot Springs Lodge Space Heating Low Temperature Geothermal Facility Hot Springs Lodge Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Jackson Hot Springs Lodge Space Heating Low Temperature Geothermal Facility Facility Jackson Hot Springs Lodge Sector Geothermal energy Type Space Heating Location Jackson, Montana Coordinates 45.3679793°, -113.4089438° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

106

Box Canyon Motel Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Motel Space Heating Low Temperature Geothermal Facility Motel Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Box Canyon Motel Space Heating Low Temperature Geothermal Facility Facility Box Canyon Motel Sector Geothermal energy Type Space Heating Location Ouray, Colorado Coordinates 38.0227716°, -107.6714487° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

107

Ophir Creek Space Heating Low Temperature Geothermal Facility | Open Energy  

Open Energy Info (EERE)

Ophir Creek Space Heating Low Temperature Geothermal Facility Ophir Creek Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Ophir Creek Space Heating Low Temperature Geothermal Facility Facility Ophir Creek Sector Geothermal energy Type Space Heating Location SW, Alaska Coordinates Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

108

Modoc High School Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Modoc High School Space Heating Low Temperature Geothermal Facility Modoc High School Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Modoc High School Space Heating Low Temperature Geothermal Facility Facility Modoc High School Sector Geothermal energy Type Space Heating Location Alturas, California Coordinates 41.4871146°, -120.5424555° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

109

East Middle School and Cayuga Community College Space Heating Low  

Open Energy Info (EERE)

Middle School and Cayuga Community College Space Heating Low Middle School and Cayuga Community College Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name East Middle School and Cayuga Community College Space Heating Low Temperature Geothermal Facility Facility East Middle School and Cayuga Community College Sector Geothermal energy Type Space Heating Location Auburn, New York Coordinates 42.9317335°, -76.5660529° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

110

Indian Springs School Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

School Space Heating Low Temperature Geothermal Facility School Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Indian Springs School Space Heating Low Temperature Geothermal Facility Facility Indian Springs School Sector Geothermal energy Type Space Heating Location Big Bend, California Coordinates 39.6982182°, -121.4608015° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

111

Manley Hot Springs Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Manley Hot Springs Space Heating Low Temperature Geothermal Facility Facility Manley Hot Springs Sector Geothermal energy Type Space Heating Location Manley Hot Springs, Alaska Coordinates 65.0011111°, -150.6338889° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

112

Ft Bidwell Space Heating Low Temperature Geothermal Facility | Open Energy  

Open Energy Info (EERE)

Ft Bidwell Space Heating Low Temperature Geothermal Facility Ft Bidwell Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Ft Bidwell Space Heating Low Temperature Geothermal Facility Facility Ft Bidwell Sector Geothermal energy Type Space Heating Location Ft. Bidwell, California Coordinates Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

113

Medical Hot Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Hot Springs Space Heating Low Temperature Geothermal Facility Hot Springs Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Medical Hot Springs Space Heating Low Temperature Geothermal Facility Facility Medical Hot Springs Sector Geothermal energy Type Space Heating Location Union County, Oregon Coordinates 45.2334122°, -118.0410627° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

114

Roosevelt Warm Springs Institute for Rehab. Space Heating Low Temperature  

Open Energy Info (EERE)

Space Heating Low Temperature Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Roosevelt Warm Springs Institute for Rehab. Space Heating Low Temperature Geothermal Facility Facility Roosevelt Warm Springs Institute for Rehab. Sector Geothermal energy Type Space Heating Location Warm Springs, Georgia Coordinates 32.8904081°, -84.6810381° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

115

Vichy Hot Springs Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Vichy Hot Springs Space Heating Low Temperature Geothermal Facility Vichy Hot Springs Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Vichy Hot Springs Space Heating Low Temperature Geothermal Facility Facility Vichy Hot Springs Sector Geothermal energy Type Space Heating Location Ukiah, California Coordinates 39.1501709°, -123.2077831° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

116

Jump Steady Resort Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Jump Steady Resort Space Heating Low Temperature Geothermal Facility Jump Steady Resort Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Jump Steady Resort Space Heating Low Temperature Geothermal Facility Facility Jump Steady Resort Sector Geothermal energy Type Space Heating Location Buena Vista, Colorado Coordinates 38.8422178°, -106.1311288° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

117

Summer Lake Hot Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Summer Lake Hot Springs Space Heating Low Temperature Geothermal Facility Summer Lake Hot Springs Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Summer Lake Hot Springs Space Heating Low Temperature Geothermal Facility Facility Summer Lake Hot Springs Sector Geothermal energy Type Space Heating Location Summer Lake, Oregon Coordinates Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

118

Stroppel Hotel Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Stroppel Hotel Space Heating Low Temperature Geothermal Facility Facility Stroppel Hotel Sector Geothermal energy Type Space Heating Location Midland, South Dakota Coordinates 44.0716539°, -101.1554178° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

119

Van Norman Residences Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Norman Residences Space Heating Low Temperature Geothermal Facility Norman Residences Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Van Norman Residences Space Heating Low Temperature Geothermal Facility Facility Van Norman Residences Sector Geothermal energy Type Space Heating Location Thermopolis, Wyoming Coordinates 43.6460672°, -108.2120432° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

120

Desert Hot Springs Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Hot Springs Space Heating Low Temperature Geothermal Facility Hot Springs Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Desert Hot Springs Space Heating Low Temperature Geothermal Facility Facility Desert Hot Springs Sector Geothermal energy Type Space Heating Location Desert Hot Springs, California Coordinates 33.961124°, -116.5016784° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Ouray Municipal Pool Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Ouray Municipal Pool Space Heating Low Temperature Geothermal Facility Ouray Municipal Pool Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Ouray Municipal Pool Space Heating Low Temperature Geothermal Facility Facility Ouray Municipal Pool Sector Geothermal energy Type Space Heating Location Ouray, Colorado Coordinates 38.0227716°, -107.6714487° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

122

Canon City Area Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Canon City Area Space Heating Low Temperature Geothermal Facility Canon City Area Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Canon City Area Space Heating Low Temperature Geothermal Facility Facility Canon City Area Sector Geothermal energy Type Space Heating Location Canon City, Colorado Coordinates 38.439949°, -105.226097° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

123

Chena Hot Springs Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Chena Hot Springs Space Heating Low Temperature Geothermal Facility Facility Chena Hot Springs Sector Geothermal energy Type Space Heating Location Fairbanks, Alaska Coordinates 64.8377778°, -147.7163889° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

124

Salida Hot Springs (Poncha Spring) Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

(Poncha Spring) Space Heating Low Temperature Geothermal (Poncha Spring) Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Salida Hot Springs (Poncha Spring) Space Heating Low Temperature Geothermal Facility Facility Salida Hot Springs (Poncha Spring) Sector Geothermal energy Type Space Heating Location Salida, Colorado Coordinates 38.5347193°, -105.9989022° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

125

Modesto Memorial Hospital Space Heating Low Temperature Geothermal Facility  

Open Energy Info (EERE)

Memorial Hospital Space Heating Low Temperature Geothermal Facility Memorial Hospital Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Modesto Memorial Hospital Space Heating Low Temperature Geothermal Facility Facility Modesto Memorial Hospital Sector Geothermal energy Type Space Heating Location Modesto, California Coordinates 37.6390972°, -120.9968782° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

126

Peppermill Hotel Casino Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Peppermill Hotel Casino Space Heating Low Temperature Geothermal Facility Peppermill Hotel Casino Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Peppermill Hotel Casino Space Heating Low Temperature Geothermal Facility Facility Peppermill Hotel Casino Sector Geothermal energy Type Space Heating Location Reno, Nevada Coordinates 39.5296329°, -119.8138027° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

127

Glenwood Hot Springs Lodge Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Lodge Space Heating Low Temperature Geothermal Lodge Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Glenwood Hot Springs Lodge Space Heating Low Temperature Geothermal Facility Facility Glenwood Hot Springs Lodge Sector Geothermal energy Type Space Heating Location Glenwood Springs, Colorado Coordinates 39.5505376°, -107.3247762° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

128

St. Mary's Hospital Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Mary's Hospital Space Heating Low Temperature Geothermal Facility Mary's Hospital Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name St. Mary's Hospital Space Heating Low Temperature Geothermal Facility Facility St. Mary's Hospital Sector Geothermal energy Type Space Heating Location Pierre, South Dakota Coordinates 44.3683156°, -100.3509665° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

129

Steamboat Villa Hot Springs Spa Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Steamboat Villa Hot Springs Spa Space Heating Low Temperature Geothermal Facility Facility Steamboat Villa Hot Springs Spa Sector Geothermal energy Type Space Heating Location Reno, Nevada Coordinates 39.5296329°, -119.8138027° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

130

YMCA Space Heating Low Temperature Geothermal Facility | Open Energy  

Open Energy Info (EERE)

YMCA Space Heating Low Temperature Geothermal Facility YMCA Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name YMCA Space Heating Low Temperature Geothermal Facility Facility YMCA Sector Geothermal energy Type Space Heating Location Klamath Falls, Oregon Coordinates 42.224867°, -121.7816704° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

131

Vale Slaughter House Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Vale Slaughter House Space Heating Low Temperature Geothermal Facility Vale Slaughter House Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Vale Slaughter House Space Heating Low Temperature Geothermal Facility Facility Vale Slaughter House Sector Geothermal energy Type Space Heating Location Vale, Oregon Coordinates 43.9821055°, -117.2382311° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

132

Pagosa Springs Private Wells Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Private Wells Space Heating Low Temperature Geothermal Private Wells Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Pagosa Springs Private Wells Space Heating Low Temperature Geothermal Facility Facility Pagosa Springs Private Wells Sector Geothermal energy Type Space Heating Location Pagosa Springs, Colorado Coordinates 37.26945°, -107.0097617° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

133

Avila Hot Springs Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Avila Hot Springs Space Heating Low Temperature Geothermal Facility Facility Avila Hot Springs Sector Geothermal energy Type Space Heating Location San Luis Obispo, California Coordinates 35.2827524°, -120.6596156° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

134

Hunters Hot Spring Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Hunters Hot Spring Space Heating Low Temperature Geothermal Facility Hunters Hot Spring Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Hunters Hot Spring Space Heating Low Temperature Geothermal Facility Facility Hunters Hot Spring Sector Geothermal energy Type Space Heating Location Lakeview, Oregon Coordinates 42.1887721°, -120.345792° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

135

Klamath Residence (500) Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Residence (500) Space Heating Low Temperature Geothermal Facility Residence (500) Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Klamath Residence (500) Space Heating Low Temperature Geothermal Facility Facility Klamath Residence (500) Sector Geothermal energy Type Space Heating Location Klamath Falls, Oregon Coordinates 42.224867°, -121.7816704° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

136

Klamath Apartment Buildings (13) Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Apartment Buildings (13) Space Heating Low Temperature Geothermal Apartment Buildings (13) Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Klamath Apartment Buildings (13) Space Heating Low Temperature Geothermal Facility Facility Klamath Apartment Buildings (13) Sector Geothermal energy Type Space Heating Location Klamath Falls, Oregon Coordinates 42.224867°, -121.7816704° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

137

Klamath Churches (5) Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Churches (5) Space Heating Low Temperature Geothermal Facility Churches (5) Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Klamath Churches (5) Space Heating Low Temperature Geothermal Facility Facility Klamath Churches (5) Sector Geothermal energy Type Space Heating Location Klamath Falls, Oregon Coordinates 42.224867°, -121.7816704° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

138

Klamath County Jail Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

County Jail Space Heating Low Temperature Geothermal Facility County Jail Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Klamath County Jail Space Heating Low Temperature Geothermal Facility Facility Klamath County Jail Sector Geothermal energy Type Space Heating Location Klamath Falls, Oregon Coordinates 42.224867°, -121.7816704° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

139

Merle West Medical Center Space Heating Low Temperature Geothermal Facility  

Open Energy Info (EERE)

Merle West Medical Center Space Heating Low Temperature Geothermal Facility Merle West Medical Center Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Merle West Medical Center Space Heating Low Temperature Geothermal Facility Facility Merle West Medical Center Sector Geothermal energy Type Space Heating Location Klamath Falls, Oregon Coordinates 42.224867°, -121.7816704° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

140

Lava Hot Springs Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Lava Hot Springs Space Heating Low Temperature Geothermal Facility Facility Lava Hot Springs Sector Geothermal energy Type Space Heating Location Lava Hot Springs, Idaho Coordinates 42.6193625°, -112.0110712° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Del Rio Hot Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Rio Hot Springs Space Heating Low Temperature Geothermal Facility Rio Hot Springs Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Del Rio Hot Springs Space Heating Low Temperature Geothermal Facility Facility Del Rio Hot Springs Sector Geothermal energy Type Space Heating Location Preston, Idaho Coordinates 42.0963133°, -111.8766173° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

142

Walley's Hot Springs Resort Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Walley's Hot Springs Resort Space Heating Low Temperature Geothermal Walley's Hot Springs Resort Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Walley's Hot Springs Resort Space Heating Low Temperature Geothermal Facility Facility Walley's Hot Springs Resort Sector Geothermal energy Type Space Heating Location Genoa, Nevada Coordinates Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

143

Utah State Prison Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Prison Space Heating Low Temperature Geothermal Facility Prison Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Utah State Prison Space Heating Low Temperature Geothermal Facility Facility Utah State Prison Sector Geothermal energy Type Space Heating Location Salt Lake City, Utah Coordinates 40.7607793°, -111.8910474° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

144

Twin Springs Resort Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Springs Resort Space Heating Low Temperature Geothermal Facility Springs Resort Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Twin Springs Resort Space Heating Low Temperature Geothermal Facility Facility Twin Springs Resort Sector Geothermal energy Type Space Heating Location Boise, Idaho Coordinates 43.6135002°, -116.2034505° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

145

Twin Peaks Motel Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Peaks Motel Space Heating Low Temperature Geothermal Facility Peaks Motel Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Twin Peaks Motel Space Heating Low Temperature Geothermal Facility Facility Twin Peaks Motel Sector Geothermal energy Type Space Heating Location Ouray, Colorado Coordinates 38.0227716°, -107.6714487° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

146

Health Spa Space Heating Low Temperature Geothermal Facility | Open Energy  

Open Energy Info (EERE)

Health Spa Space Heating Low Temperature Geothermal Facility Health Spa Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Health Spa Space Heating Low Temperature Geothermal Facility Facility Glenwood Springs Health Spa Sector Geothermal energy Type Space Heating Location Glenwood Springs, Colorado Coordinates 39.5505376°, -107.3247762° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

147

Geronimo Springs Museum Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Geronimo Springs Museum Space Heating Low Temperature Geothermal Facility Geronimo Springs Museum Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Geronimo Springs Museum Space Heating Low Temperature Geothermal Facility Facility Geronimo Springs Museum Sector Geothermal energy Type Space Heating Location Truth or Consequences, New Mexico Coordinates 33.1284047°, -107.2528069° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

148

Arrowhead Hot Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Hot Springs Space Heating Low Temperature Geothermal Facility Hot Springs Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Arrowhead Hot Springs Space Heating Low Temperature Geothermal Facility Facility Arrowhead Hot Springs Sector Geothermal energy Type Space Heating Location San Bernardino, California Coordinates 34.1083449°, -117.2897652° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

149

Medical Center Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Medical Center Space Heating Low Temperature Geothermal Facility Medical Center Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Medical Center Space Heating Low Temperature Geothermal Facility Facility Medical Center Sector Geothermal energy Type Space Heating Location Caliente, Nevada Coordinates 37.6149648°, -114.5119378° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

150

Hot Sulphur Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Hot Sulphur Springs Space Heating Low Temperature Geothermal Facility Facility Hot Sulphur Springs Sector Geothermal energy Type Space Heating Location Hot Sulphur Springs, Colorado Coordinates 40.0730411°, -106.1027991° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

151

Tecopa Hot Springs Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Tecopa Hot Springs Space Heating Low Temperature Geothermal Facility Tecopa Hot Springs Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Tecopa Hot Springs Space Heating Low Temperature Geothermal Facility Facility Tecopa Hot Springs Sector Geothermal energy Type Space Heating Location Inyo County, California Coordinates 36.3091865°, -117.5495846° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

152

Saratoga Springs Resort Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Saratoga Springs Resort Space Heating Low Temperature Geothermal Facility Facility Saratoga Springs Resort Sector Geothermal energy Type Space Heating Location Lehi, Utah Coordinates 40.3916172°, -111.8507662° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

153

Bell Island Space Heating Low Temperature Geothermal Facility | Open Energy  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Bell Island Space Heating Low Temperature Geothermal Facility Facility Bell Island Sector Geothermal energy Type Space Heating Location Ketchikan, Alaska Coordinates 55.3422222°, -131.6461111° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

154

Warner Springs Ranch Resort Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Warner Springs Ranch Resort Space Heating Low Temperature Geothermal Warner Springs Ranch Resort Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Warner Springs Ranch Resort Space Heating Low Temperature Geothermal Facility Facility Warner Springs Ranch Resort Sector Geothermal energy Type Space Heating Location San Diego, California Coordinates 32.7153292°, -117.1572551° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

155

Jackson Well Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Well Springs Space Heating Low Temperature Geothermal Facility Well Springs Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Jackson Well Springs Space Heating Low Temperature Geothermal Facility Facility Jackson Well Springs Sector Geothermal energy Type Space Heating Location Ashland, Oregon Coordinates 42.1853257°, -122.6980457° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

156

Banbury Hot Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Banbury Hot Springs Space Heating Low Temperature Geothermal Facility Facility Banbury Hot Springs Sector Geothermal energy Type Space Heating Location Buhl, Idaho Coordinates 42.5990714°, -114.7594946° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

157

Questar Gas - Home Builder Gas Appliance Rebate Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

Questar Gas - Home Builder Gas Appliance Rebate Program Questar Gas - Home Builder Gas Appliance Rebate Program Questar Gas - Home Builder Gas Appliance Rebate Program < Back Eligibility Construction Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Construction Commercial Weatherization Design & Remodeling Appliances & Electronics Water Heating Program Info Start Date 7/1/2009 State Wyoming Program Type Utility Rebate Program Rebate Amount Energy Star Home Certification: $500 Storage Water Heater: $50 Tankless Water Heater: $300 Furnace: $300 Boiler: $400 Provider Questar Gas Questar Gas provides incentives for home builders to construct energy efficient homes. Rebates are provided for both energy efficient gas equipment and whole home Energy Star certification. All equipment and

158

Questar Gas - Home Builder Gas Appliance Rebate Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

Questar Gas - Home Builder Gas Appliance Rebate Program Questar Gas - Home Builder Gas Appliance Rebate Program Questar Gas - Home Builder Gas Appliance Rebate Program < Back Eligibility Construction Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Construction Commercial Weatherization Design & Remodeling Appliances & Electronics Water Heating Program Info State Utah Program Type Utility Rebate Program Rebate Amount Exterior Wall Insulation: $350 (single family), $150 (multifamily) Windows: $2.50/sq. ft. Gas Furnace: $200 - $400 Gas Storage Water Heater: $50-$100 Gas Condensing Water Heater: $350 Gas Boiler: $400 -$600 Tankless Gas Water Heater: $350 Single Family Homes (New Construction): $50 - $500 Multifamily Homes (New Construction): $50 - $300/unit

159

Secretary Chu Announces More Stringent Appliance Standards for Home Water  

Broader source: Energy.gov (indexed) [DOE]

Stringent Appliance Standards for Home Stringent Appliance Standards for Home Water Heaters and Other Heating Products Secretary Chu Announces More Stringent Appliance Standards for Home Water Heaters and Other Heating Products April 1, 2010 - 12:00am Addthis WASHINGTON - U.S. Department of Energy Secretary Steven Chu announced today that the Department has finalized higher energy efficiency standards for a key group of heating appliances that will together save consumers up to $10 billion and prevent up to 164 million metric tons of carbon dioxide emissions over 30 years. These new standards - for residential water heaters, pool heaters and direct heating equipment such as gas fireplaces - will reduce air pollution, prevent the release of harmful nitrogen oxides and mercury, and avoid emissions equivalent to taking 46 million cars off

160

Measure Guideline: Combustion Safety for Natural Draft Appliances Through Appliance Zone Isolation  

SciTech Connect (OSTI)

This measure guideline covers how to assess and carry out the isolation of natural draft combustion appliances from the conditioned space of low-rise residential buildings. It deals with combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage. This subset of houses does not require comprehensive combustion safety tests and simplified prescriptive procedures can be used to address safety concerns. This allows residential energy retrofit contractors inexperienced in advanced combustion safety testing to effectively address combustion safety issues and allow energy retrofits including tightening and changes to distribution and ventilation systems to proceed.

Fitzgerald, J.; Bohac, D.

2014-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Thermal Solar Energy Systems for Space Heating of Buildings  

E-Print Network [OSTI]

to compensate the deficit. In this case a traditional solar heating system having the same characteristics with regard to the solar collecting area and the volume of storage tank is used. It can be concluded that the space heating system using a solar energy...

Gomri, R.; Boulkamh, M.

2010-01-01T23:59:59.000Z

162

Building Technologies Office: Water Heating Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Water Heating Research Water Heating Research to someone by E-mail Share Building Technologies Office: Water Heating Research on Facebook Tweet about Building Technologies Office: Water Heating Research on Twitter Bookmark Building Technologies Office: Water Heating Research on Google Bookmark Building Technologies Office: Water Heating Research on Delicious Rank Building Technologies Office: Water Heating Research on Digg Find More places to share Building Technologies Office: Water Heating Research on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research Windows, Skylights, & Doors Research Space Heating & Cooling Research Water Heating Research Lighting Research Sensors & Controls Research Energy Efficient Buildings Hub

163

Cowlitz County PUD - Residential Energy Efficient Appliance Rebate Program  

Broader source: Energy.gov (indexed) [DOE]

Cowlitz County PUD - Residential Energy Efficient Appliance Rebate Cowlitz County PUD - Residential Energy Efficient Appliance Rebate Program Cowlitz County PUD - Residential Energy Efficient Appliance Rebate Program < Back Eligibility Residential Savings Category Appliances & Electronics Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount Refrigerator/Freezer: $25 Refrigerator/Freezer Recycling: $30 Clothes Washer: $30 - $70 Water Heater: $25 - $70 Provider Cowlitz County Public Utility District Cowlitz County PUD offers the EnergySHARE Plus appliance rebate program to its residential customers. Rebates are offered for Energy Star clothes washers, refrigerators and freezers (including the proper recycling of old units), and energy efficient water heaters. Rebates range from $25 - $70.

164

Appliance Standards and Building Codes  

Broader source: Energy.gov (indexed) [DOE]

Program Manager Presentation Program Manager Presentation Appliance Standards and Building Codes John Cymbalsky U.S Department of Energy - Building Technologies Office john.cymbalsky@ee.doe.gov 202.287.1692 2 | Building Technologies Office eere.energy.gov Appliance Standards and Building Codes Program Goals Appliance Standards Program Goals Provide cost-effective energy savings through national appliance and equipment standards: Issue 23 final rules by end of FY2015 Deliver at least 1 qBtu of savings annually by

165

Heat pump augmented radiator for low-temperature space applications  

SciTech Connect (OSTI)

Closed-cycle, space-based heat rejection systems depend solely on radiation to achieve their heat dissipation function. Since the payload heat rejection temperature is typically 50 K above that of the radiation sink in near earth orbit, the size and mass of these systems can be appreciable. Size (and potentially mass) reductions are achievable by increasing the rejection temperature via a heat pump. Two heat pump concept were examined to determine if radiator area reductions could be realized without increasing the mass of the heat rejection system. The first was a conventional, electrically-driven vapor compression system. The second is an innovative concept using a solid-vapor adsorption system driven by reject heat from the prime power system. The mass and radiator area of the heat pumpradiator systems were compared to that of a radiator only system to determine the merit of the heat pump concepts. Results for the compressor system indicated that the mass minimum occured at a temperature lift of about 50 K and radiator area reductions of 35% were realized. With a radiator specific mass of 10 kgm/sup 2/, the heat pump system is 15% higher than the radiator only baseline system. The complex compound chemisorption systems showed more promising results. Using water vapor as the working fluid in a single stage heat amplifier resulted in optimal temperature lifts exceeding 150 K. This resulted in a radiator area reduction of 83% with a mass reduction of 64%. 7 refs., 9 figs.

Olszewski, M.; Rockenfeller, U.

1988-01-01T23:59:59.000Z

166

CALIFORNIA STATEWIDE RESIDENTIAL APPLIANCE  

E-Print Network [OSTI]

methodology and results report that includes energy consumption tables from the conditional demand analysis Energy Consumption and Appliance Saturation Summaries. Results from the Conditional Demand Analysis (CDA conditioning is the primary driver of peak energy demand in California and the saturation of central air

167

Chico Hot Springs Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Facility Chico Hot Springs Sector Geothermal energy Type Space Heating Location Pray, Montana Coordinates 45.3802143°, -110.6815999° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

168

Circle Hot Springs Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Facility Circle Hot Springs Sector Geothermal energy Type Space Heating Location Fairbanks, Alaska Coordinates 64.8377778°, -147.7163889° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

169

Buckhorn Mineral Wells Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Facility Buckhorn Mineral Wells Sector Geothermal energy Type Space Heating Location Mesa, Arizona Coordinates 33.4222685°, -111.8226402° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

170

Jemez Springs Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Facility Jemez Springs Sector Geothermal energy Type Space Heating Location Jemez Springs, New Mexico Coordinates 35.7686356°, -106.692258° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

171

Breitenbush Hot Springs Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Facility Breitenbush Hot Springs Sector Geothermal energy Type Space Heating Location Marion County, Oregon Coordinates 44.8446393°, -122.5927411° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

172

Fairmont Hot Springs Resort Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Facility Facility Jump to: navigation, search Name Fairmont Hot Springs Resort Space Heating Low Temperature Geothermal Facility Facility Fairmont Hot Springs Resort Sector Geothermal energy Type Space Heating Location Fairmont, Montana Coordinates Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

173

Low Temperature Direct Use Space Heating Geothermal Facilities | Open  

Open Energy Info (EERE)

Low Temperature Direct Use Space Heating Geothermal Facilities Low Temperature Direct Use Space Heating Geothermal Facilities Jump to: navigation, search Loading map... {"format":"googlemaps3","type":"ROADMAP","types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"limit":800,"offset":0,"link":"all","sort":[""],"order":[],"headers":"show","mainlabel":"","intro":"","outro":"","searchlabel":"\u2026 further results","default":"","geoservice":"google","zoom":false,"width":"600px","height":"350px","centre":false,"layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","icon":"","visitedicon":"","forceshow":true,"showtitle":true,"hidenamespace":false,"template":"Geothermal

174

Glendale Water and Power - Energy Efficiency Appliance Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

Energy Efficiency Appliance Rebate Energy Efficiency Appliance Rebate Program Glendale Water and Power - Energy Efficiency Appliance Rebate Program < Back Eligibility Low-Income Residential Residential Savings Category Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Program Info State California Program Type Utility Rebate Program Rebate Amount First rebate amount purchased outside Glendale, second purchased inside Glendale. Clothes Washer: $60 - $80 Refrigerator: $60 - $80 Dishwasher: $30 - $40 Room Air Conditioners: $50 - $60 Central Air Conditioners: $100 - $125/ton Ceiling Fan: $15 - $20 Solar Attic Fan $100 - $125 Pool Pump: $100 - $125 Provider GWP Rebate Program Glendale Water and Power (GPW) offers the Smart Home Energy and Water Saving Rebate Program that includes several incentives for residential

175

New York - Residential Energy Efficient Appliance Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

New York - Residential Energy Efficient Appliance Rebate Program New York - Residential Energy Efficient Appliance Rebate Program New York - Residential Energy Efficient Appliance Rebate Program < Back Eligibility Multi-Family Residential Residential Savings Category Appliances & Electronics Commercial Lighting Lighting Heating & Cooling Commercial Heating & Cooling Cooling Maximum Rebate $4,999 per item $20,000 per government entity Program Info Funding Source U.S. DOE Energy Efficiency and Conservation Block Grant (EECBG) Start Date 09/25/2012 Expiration Date 3/12/2013 State New York Program Type State Rebate Program Rebate Amount 75% of purchase price '''''Note: Under the American Recovery and Reinvestment Act (ARRA) of 2009, the U.S. Department of Energy (DOE) is providing a total of $300 million to U.S. states, U.S. territories and the District of Columbia to establish

176

Heat kernels on metric measure spaces with regular volume Alexander Grigor'yan  

E-Print Network [OSTI]

Heat kernels on metric measure spaces with regular volume growth Alexander Grigor'yan Department In this survey we study heat kernel estimates of self-similar type on metric mea- sure spaces with regular volume and phrases. Heat kernel, metric measure space, maximum principle, heat semigroup Contents 1 Introduction 2 1

Grigor'yan, Alexander

177

Heat kernels on metric measure spaces with regular volume Alexander Grigor'yan #  

E-Print Network [OSTI]

Heat kernels on metric measure spaces with regular volume growth Alexander Grigor'yan # Department In this survey we study heat kernel estimates of self­similar type on metric mea­ sure spaces with regular volume and phrases. Heat kernel, metric measure space, maximum principle, heat semigroup Contents 1 Introduction 2 1

Grigor'yan, Alexander

178

Tips: Heat Pumps | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Heat Pumps Heat Pumps Tips: Heat Pumps June 24, 2013 - 5:48pm Addthis Heat pumps can be a cost-effective choice in moderate climates, especially if you heat your home with electricity. Heat pumps can be a cost-effective choice in moderate climates, especially if you heat your home with electricity. Heat pumps are the most efficient form of electric heating in moderate climates. Because they move heat rather than generate heat, heat pumps can provide equivalent space conditioning at as little as one quarter of the cost of operating conventional heating or cooling appliances. A heat pump does double duty as a central air conditioner by collecting the heat inside your house and pumping it outside. There are three types of heat pumps: air-to-air, water source, and geothermal. They collect heat from the air, water, or ground outside your

179

Sales Tax Holiday for Energy-Efficient Appliances | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Sales Tax Holiday for Energy-Efficient Appliances Sales Tax Holiday for Energy-Efficient Appliances Sales Tax Holiday for Energy-Efficient Appliances < Back Eligibility Multi-Family Residential Residential Savings Category Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Heat Pumps Program Info Start Date 7/1/2008 State North Carolina Program Type Sales Tax Incentive Rebate Amount 100% sales tax exemption for certain Energy Star appliances Provider N.C. Department of Revenue '''Note: Legislation enacted in June 2011 ([http://www.ncleg.net/enactedlegislation/sessionlaws/html/2011-2012/sl201... S.B. 267]) that removed geothermal heat pumps from the list of energy systems and equipment eligible for this exemption.''' In July 2008, North Carolina enacted legislation establishing a "sales tax

180

Department of Energy Opens Appliance Standards Investigation for Certain  

Broader source: Energy.gov (indexed) [DOE]

Department of Energy Opens Appliance Standards Investigation for Department of Energy Opens Appliance Standards Investigation for Certain Air Con International Air Conditioners and Heat Pumps Department of Energy Opens Appliance Standards Investigation for Certain Air Con International Air Conditioners and Heat Pumps March 26, 2010 - 6:55pm Addthis WASHINGTON, DC - The U.S. Department of Energy announced today that it has opened an investigation to determine whether certain air conditioners and heat pump products manufactured by Air Con International comply with federal energy efficiency standards. The subpoena issued on Wednesday requires Air Con to submit detailed information about the energy consumption of its products and how Air Con marketed and sold them in the U.S. This action follows similar subpoenas issued earlier in the week for

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Department of Energy Opens Appliance Standards Investigation for Certain  

Broader source: Energy.gov (indexed) [DOE]

Department of Energy Opens Appliance Standards Investigation for Department of Energy Opens Appliance Standards Investigation for Certain Air Con International Air Conditioners and Heat Pumps Department of Energy Opens Appliance Standards Investigation for Certain Air Con International Air Conditioners and Heat Pumps March 26, 2010 - 6:55pm Addthis WASHINGTON, DC - The U.S. Department of Energy announced today that it has opened an investigation to determine whether certain air conditioners and heat pump products manufactured by Air Con International comply with federal energy efficiency standards. The subpoena issued on Wednesday requires Air Con to submit detailed information about the energy consumption of its products and how Air Con marketed and sold them in the U.S. This action follows similar subpoenas issued earlier in the week for

182

Appliances & Electronics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Appliances & Electronics Appliances & Electronics Appliances & Electronics Looking for ways to save energy? Check out these tips -- which include using a power strip and switching to ENERGY STAR appliances -- that every homeowner should try. Looking for ways to save energy? Check out these tips -- which include using a power strip and switching to ENERGY STAR appliances -- that every homeowner should try. Over the past couple of decades, advances in appliances and electronics -- from microwaves and dishwashers to smartphones and computers -- have changed the way we use energy in our homes. Through the Energy Department's appliance standards, manufacturers are making great strides in developing new, more efficient appliances that are

183

Hydrogen Generator Appliance | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Hydrogen Generator Appliance Hydrogen Generator Appliance Presentation by Gus Block, Nuvera Fuel Cells, at the Natural Gas and Hydrogen Infrastructure Opportunities Workshop held...

184

Study of the Heating Load of a Manufactured Space with a Gas-fired Radiant Heating System  

E-Print Network [OSTI]

A thermal balance mathematics model of a manufactured space with a gas-fired radiant heating system is established to calculate the heating load. Computer programs are used to solve the model. Envelope internal surface temperatures under different...

Zheng, X.; Dong, Z.

2006-01-01T23:59:59.000Z

185

A REVIEW OF ASSUMPTIONS AND ANALYSIS IN EPRI EA-3409,"HOUSEHOLD APPLIANCE CHOICE: REVISION OF REEPS BEHAVIORAL MODELS"  

SciTech Connect (OSTI)

This paper revises and extends EPRI report EA-3409, ''Household Appliance Choice: Revision of REEPS Behavioral Models.'' That paper reported the results of an econometric study of major appliance choice in new residential construction. Errors appeared in two tables of that report. We offer revised versions of those tables, and a brief analysis of the consequences and significance of the errors. The present paper also proposes several possible extensions and re-specifications of the models examined by EPRI. Some of these are judged to be highly successful; they both satisfy economic intuition more completely than the original specification and produce a better quality fit to the dependent variable. We feel that inclusion of these modifications produces a more useful set of coefficients for economic modeling than the original specification. This paper focuses on EPRI's models of residential space heating technology choice. That choice was modeled as a nested logit structure, with consumers choosing whether to have central air conditioning or not, and, given that choice, what kind of space heating system to have. The model included five space heating alternatives with central cooling (gas, oil, and electric forced-air; heat pumps; and electric baseboard) and eight alternatives without it (gas, oil, and electric forced-air; gas and oil boilers and non-central systems; and electric baseboard heat). The structure of the nested logit model is shown in Figure 1.

Wood, D.J.; Ruderman, H.; McMahon, J. E.

1989-05-01T23:59:59.000Z

186

Electric equipment providing space conditioning, water heating, and refrigeration consumes 12.5% of the nation's  

E-Print Network [OSTI]

Electric equipment providing space conditioning, water heating, and refrigeration consumes 12 are the heart of air conditioners, heat pumps, chillers, supermarket refrigeration systems, and more. Global use of vapor compression system configurations including multi-functional integrated heat pumps, multi

Oak Ridge National Laboratory

187

DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air...  

Broader source: Energy.gov (indexed) [DOE]

Minimum Appliance Standards DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards June 3, 2010 - 2:17pm Addthis...

188

Analysis of a solar assisted heat pump system for indoor swimming pool water and space heating  

Science Journals Connector (OSTI)

Solar energy application is a good alternative to replace primary energy source especially for large-scale installations. Heat pumps are also effective means to reduce primary energy consumption. This paper describes a case study with a new design of solar assisted heat pump (SAHP) for indoor swimming pool space- and water-heating purposes. The system design procedure was first presented. The entire system was then modeled via the TRNSYS simulation environment and the energy performance was evaluated based on the winter time operation schedule. Economic analysis with a range of collector areas was also performed. The simulation results show that the overall system COP can reach 4.5, and the fractional factor of energy saving is 79% as compared to the conventional energy system. The economical payback period is less than 5years.

T.T. Chow; Y. Bai; K.F. Fong; Z. Lin

2012-01-01T23:59:59.000Z

189

Energy Star Appliances 1 Texas A&M AgriLife Extension Service ENERGY STAR Appliances  

E-Print Network [OSTI]

Energy Star® Appliances 1 Texas A&M AgriLife Extension Service ENERGY STAR® Appliances ENERGY STAR®-labeled appliances save you money by using less electricity and water than other appliances. Better appliance energy efficiency comes from quality materials and technologically advanced materials. Although energy efficient

190

Tips: Shopping for Appliances | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tips: Shopping for Appliances Tips: Shopping for Appliances Tips: Shopping for Appliances April 24, 2012 - 7:33pm Addthis What's the Real Cost? Every appliance has two price tags -- the purchase price and the operating cost. Consider both when buying a new appliance. What's the Real Cost? Every appliance has two price tags -- the purchase price and the operating cost. Consider both when buying a new appliance. When you're shopping for appliances, think of two price tags. The first one covers the purchase price -- think of it as a down payment. The second price tag is the cost of operating the appliance during its lifetime. You'll be paying on that second price tag every month with your utility bill for the next 10 to 20 years, depending on the appliance. Refrigerators last an average of 12 years; clothes washers about 11 years; dishwashers

191

Energy Star Appliances  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Showerheads Residential Weatherization Performance Tested Comfort Systems Ductless Heat Pumps New Construction Residential Marketing Toolkit Retail Sales Allocation Tool...

192

Close-spaced thermionic converters with active spacing control and heat-pipe isothermal emitters  

SciTech Connect (OSTI)

Thermionic converters with interelectrode gaps smaller than 10 microns are capable of substantial performance improvements over conventional ignited mode diodes. Previous devices which have demonstrated operation at such small gaps have done so at low power densities and emitter temperatures. Higher power operation requires overcoming two primary design issues: thermal distortion of the emitter due to temperature gradients and degradation of the in-gap spacers at higher emitter temperatures. This work describes two innovations for solution of these issues. The issue of thermal distortion was addressed by an isothermal emitter incorporating a heat-pipe into its structure. Such a heat-pipe emitter, with a single-crystal emitting surface, was fabricated and characterized. Finite-element computational modeling was used to analyze its distortion with an applied heat flux. The calculations suggested that thermal distortion would be significantly reduced as compared with a solid emitter. Ongoing work and preliminary experimental results are described for a system of active interelectrode gap control. In the present design an integral transducer determines the interelectrode gap of the converter. Initial designs for spacing actuators and their required cesium vapor seals are discussed. A novel hot-shell converter design incorporating active spacing control and low-temperature seals is presented. A converter incorporating the above features would be capable of near ideal-converter performance at high power densities. In addition, active spacing control can potentially completely eliminate short-circuit failures in thermionic converter systems.

Fitzpatrick, G.O.; Koester, J.K.; Chang, J.; Britt, E.J.; McVey, J.B. [Space Power, Inc., San Jose, CA (United States)

1996-12-31T23:59:59.000Z

193

Using handhelds for wireless remote control of PCs and appliances  

Science Journals Connector (OSTI)

......upnp.org ). UPnP provides standard protocols for controlling appliances...feedback about state, and defines standard sets of functionality for different...devices. Already, there are standards for devices such as printers...equipment, lighting, and HVAC (heating, venting and air......

Brad A. Myers

2005-05-01T23:59:59.000Z

194

"Table HC14.4 Space Heating Characteristics by West Census Region, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

4 Space Heating Characteristics by West Census Region, 2005" 4 Space Heating Characteristics by West Census Region, 2005" " Million U.S. Housing Units" ,,"West Census Region" ,"U.S. Housing Units (millions)" ,,,"Census Division" ,,"Total West" "Space Heating Characteristics",,,"Mountain","Pacific" "Total",111.1,24.2,7.6,16.6 "Do Not Have Space Heating Equipment",1.2,0.7,"Q",0.7 "Have Main Space Heating Equipment",109.8,23.4,7.5,16 "Use Main Space Heating Equipment",109.1,22.9,7.4,15.4 "Have Equipment But Do Not Use It",0.8,0.6,"Q",0.5 "Main Heating Fuel and Equipment" "Natural Gas",58.2,14.7,4.6,10.1 "Central Warm-Air Furnace",44.7,11.4,4,7.4

195

"Table HC12.4 Space Heating Characteristics by Midwest Census Region, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

4 Space Heating Characteristics by Midwest Census Region, 2005" 4 Space Heating Characteristics by Midwest Census Region, 2005" " Million U.S. Housing Units" ,,"Midwest Census Region" ,"U.S. Housing Units (millions)" ,,,"Census Division" ,,"Total Midwest" "Space Heating Characteristics",,,"East North Central","West North Central" "Total",111.1,25.6,17.7,7.9 "Do Not Have Space Heating Equipment",1.2,"Q","Q","N" "Have Main Space Heating Equipment",109.8,25.6,17.7,7.9 "Use Main Space Heating Equipment",109.1,25.6,17.7,7.9 "Have Equipment But Do Not Use It",0.8,"N","N","N" "Main Heating Fuel and Equipment"

196

Practical Analysis of a New Type Radiant Heating Technology in a Large Space Building  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Heating technologies fo r energy efficiency Vol.III-3-4 Practical Analysis of a New Type Radiant Heating Technology in a Large Space Building Guohui Feng Guangyu Cao Li Gang Ph.D. Ph... achieve above 95%. Since not heating up indoor air, it is specially suited for heating of factory buildings where the conditions of heat preservation and sealing are poor and their gates are opened frequently. The off-on of radiation heating system...

Feng, G.; Cao, G.; Gang, L.

2006-01-01T23:59:59.000Z

197

Students Compete to Design Energy-Efficient Appliances | Department of  

Broader source: Energy.gov (indexed) [DOE]

Students Compete to Design Energy-Efficient Appliances Students Compete to Design Energy-Efficient Appliances Students Compete to Design Energy-Efficient Appliances May 10, 2012 - 1:39pm Addthis 1 of 5 Team Cal Poly Solar is working to significantly reduce the cost and construction time on their solar concentrator for cooking. Image: Lawrence Berkeley National Laboratory 2 of 5 Professor Dale Dolan's students from California Polytechnic State University San Luis Obispo Electrical Engineering department testing the placement of their Hybrid Solar Photovoltaic Panel for Pool Heating. Image: Lawrence Berkeley National Laboratory 3 of 5 Students from the University of Maryland working hard to make a residential air condition unit more efficient. Image: Lawrence Berkeley National Laboratory 4 of 5 Team Ohio State's vapor compression hybrid air/water conditioning system

198

Students Compete to Design Energy-Efficient Appliances | Department of  

Broader source: Energy.gov (indexed) [DOE]

Students Compete to Design Energy-Efficient Appliances Students Compete to Design Energy-Efficient Appliances Students Compete to Design Energy-Efficient Appliances May 10, 2012 - 1:39pm Addthis 1 of 5 Team Cal Poly Solar is working to significantly reduce the cost and construction time on their solar concentrator for cooking. Image: Lawrence Berkeley National Laboratory 2 of 5 Professor Dale Dolan's students from California Polytechnic State University San Luis Obispo Electrical Engineering department testing the placement of their Hybrid Solar Photovoltaic Panel for Pool Heating. Image: Lawrence Berkeley National Laboratory 3 of 5 Students from the University of Maryland working hard to make a residential air condition unit more efficient. Image: Lawrence Berkeley National Laboratory 4 of 5 Team Ohio State's vapor compression hybrid air/water conditioning system

199

Students Compete to Design Energy-Efficient Appliances | Department of  

Broader source: Energy.gov (indexed) [DOE]

Students Compete to Design Energy-Efficient Appliances Students Compete to Design Energy-Efficient Appliances Students Compete to Design Energy-Efficient Appliances May 10, 2012 - 1:39pm Addthis 1 of 5 Team Cal Poly Solar is working to significantly reduce the cost and construction time on their solar concentrator for cooking. Image: Lawrence Berkeley National Laboratory 2 of 5 Professor Dale Dolan's students from California Polytechnic State University San Luis Obispo Electrical Engineering department testing the placement of their Hybrid Solar Photovoltaic Panel for Pool Heating. Image: Lawrence Berkeley National Laboratory 3 of 5 Students from the University of Maryland working hard to make a residential air condition unit more efficient. Image: Lawrence Berkeley National Laboratory 4 of 5 Team Ohio State's vapor compression hybrid air/water conditioning system

200

"Table HC13.4 Space Heating Characteristics by South Census Region, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

4 Space Heating Characteristics by South Census Region, 2005" 4 Space Heating Characteristics by South Census Region, 2005" " Million U.S. Housing Units" ,,"South Census Region" ,"U.S. Housing Units (millions)" ,,,"Census Division" ,,"Total South" "Space Heating Characteristics",,,"South Atlantic","East South Central","West South Central" "Total",111.1,40.7,21.7,6.9,12.1 "Do Not Have Space Heating Equipment",1.2,"Q","Q","N","Q" "Have Main Space Heating Equipment",109.8,40.3,21.4,6.9,12 "Use Main Space Heating Equipment",109.1,40.1,21.2,6.9,12 "Have Equipment But Do Not Use It",0.8,"Q","Q","N","N"

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Packaged Terminal Air Conditioners and Heat Pumps Packaged Terminal Air Conditioners and Heat Pumps Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of packaged terminal air conditioners and heat pumps since 1994. Packaged terminal air conditioners (PTACs) and packaged terminal heat pumps (PTHPs) are through-the-wall space conditioning units commonly used in lodging, townhouse office complexes, and extended care facilities. The current standard will save approximately 0.04 quads of energy and result in approximately $32 million in energy bill savings for products shipped from 2012-2042. The standard will avoid about 2 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 392,000 automobiles.

202

Energy efficiency choice in the purchase of residential appliances  

SciTech Connect (OSTI)

This paper provides a quantitative analysis of the behavior of the market for the purchase of energy efficiency in residential appliances and heating and cooling equipment. We examine the historical efficiency choices over the period 1972 to 1980 for eight consumer products: gas central space heaters, oil central space heaters, room air conditioners, central air conditioners, electric water heaters, gas water heaters, refrigerators, and freezers. We characterize the behavior of the market for these products by an aggregate market discount rate. Except for air conditioners, the observed discount rates are much higher than real interest rates or the discount rates commonly used in life-cycle cost analysis of consumer choice. They appear to be relatively constant, even though fuel prices escalated rapidly over the time period. We conclude from these results that the market for energy efficiency is not performing well. Several explanations of the under investment in efficiency are proposed: (1) lack of information about the costs and benefits of energy efficiency; (2) prevalence of third party purchasers; (3) unavailability of highly efficient equipment without other features; (4) long manufacturing lead times; and (5) other marketing strategies.

Ruderman, H.; Levine, M.D.; McMahon, J.E.

1984-07-01T23:59:59.000Z

203

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Small, Large, and Very Large Commercial Package Air Conditioners and Heat Pumps Small, Large, and Very Large Commercial Package Air Conditioners and Heat Pumps Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) regulates the energy efficiency of small, large, and very large commercial package air conditioners and heat pumps. Commercial air conditioners and heat pumps are air-cooled, water-cooled, evaporatively-cooled, or water source unitary air conditioners or heat pumps that are used for space conditioning of commercial and industrial buildings. The standards implemented in 2010 for small and large, air-cooled commercial package air conditioners and heat pumps, and SPVUs, will save approximately 1.7 quads of energy and result in approximately $28.9 billion in energy bill savings for products shipped from 2010-2034. These standards will avoid about 90.3 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of 31.1 million automobiles. The standard implemented in 2010 for very large, air-cooled commercial package air conditioners and heat pumps will save approximately 0.43 quads of energy and result in approximately $4.3 billion in energy bill savings for products shipped from 2010-2034. The standard will avoid about 22.6 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of 4.4 million automobiles.

204

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Residential Central Air Conditioners and Heat Pumps Residential Central Air Conditioners and Heat Pumps Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy's (DOE) energy conservation standards for residential central air conditioners and heat pumps since 1992. Residential central air conditioners and heat pumps are installed as part of a home's central heating and cooling system. They use ducts to distribute cooled or dehumidified air to more than one room. Residential central air conditioners and heat pumps include split system central air conditioners and heat pumps; single package central air conditioners, small-duct high-velocity products, and space constrained products. The standards mandatory in 1992 and 1993 will save approximately 2.9 quads of energy and result in approximately $29 billion in energy bill savings from 1993-2023. The standard will avoid about 160 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 31.4 million automobiles.

205

Economizer refrigeration cycle space heating and cooling system and process  

DOE Patents [OSTI]

This invention relates to heating and cooling systems and more particularly to an improved system utilizing a Stirling Cycle engine heat pump in a refrigeration cycle. 18 figs.

Jardine, D.M.

1983-03-22T23:59:59.000Z

206

Economizer refrigeration cycle space heating and cooling system and process  

DOE Patents [OSTI]

This invention relates to heating and cooling systems and more particularly to an improved system utilizing a Stirling Cycle engine heat pump in a refrigeration cycle.

Jardine, Douglas M. (Colorado Springs, CO)

1983-01-01T23:59:59.000Z

207

Lightning Dock Geothermal Space Heating Project: Lightning Dock...  

Open Energy Info (EERE)

and home heating systems, which consisted of pumping geothermal water and steam through passive steam heaters, and convert the systems to one using modern heat exchange units. It...

208

On Variations of Space-heating Energy Use in Office Buildings  

E-Print Network [OSTI]

HPB IEA IEAD LPD MJ NFRC SHC SHGC TRNSYS WWR VAV VT Americanheat gain coefficient (SHGC) reduce space-heating loads. Thetemperature difference. The SHGC represents the fractional

Lin, Hung-Wen

2014-01-01T23:59:59.000Z

209

"Table HC7.5 Space Heating Usage Indicators by Household Income, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

5 Space Heating Usage Indicators by Household Income, 2005" 5 Space Heating Usage Indicators by Household Income, 2005" " Million U.S. Housing Units" ,,"2005 Household Income",,,,,"Below Poverty Line","Eligible for Federal Assistance1" ,"Housing Units (millions)" ,,"Less than $20,000","$20,000 to $39,999","$40,000 to $59,999","$60,000 to $79,999","$80,000 or More" "Space Heating Usage Indicators" "Total U.S. Housing Units",111.1,26.7,28.8,20.6,13.1,22,16.6,38.6 "Do Not Have Heating Equipment",1.2,0.5,0.3,0.2,"Q",0.2,0.3,0.6 "Have Space Heating Equipment",109.8,26.2,28.5,20.4,13,21.8,16.3,37.9 "Use Space Heating Equipment",109.1,25.9,28.1,20.3,12.9,21.8,16,37.3

210

Appliance Standards : New Concepts : From the Lab to the Marketplace-Ten  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Appliance Standards Appliance Standards From the Lab to the Marketplace Ten Years Later, Energy Efficient Technologies from Research at the Lawrence Berkeley National Laboratory Berkeley Lab logo (left) with six rows of gray dots transitioning to a line art drawing of a cityscape and residential houses. Appliance Standards Residential consumers spent $215 billion and commercial consumers spend $154 billion in 20051 on energy for appliances, heating and cooling equipment and lighting, which consumption resulted in 2305 million metric tons of carbon dioxide emissions2. For many years, Berkeley Lab researchers have provided the technical analysis used by the Department of Energy as it established energy efficiency standards for appliances mandated by law. Berkeley Lab's energy policy work includes analyzing the effects on energy

211

Tips: Smart Appliances | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tips: Smart Appliances Tips: Smart Appliances Tips: Smart Appliances April 24, 2012 - 7:56pm Addthis Some manufacturers are now offering "smart" appliances -- appliances that can be connected to smart electric meters or home energy management systems to help you shift your electricity use to off-peak hours. Air conditioners, refrigerators, dishwashers, and other appliances may be available as smart appliances. Smart appliances don't just turn off during times of peak electricity demand -- instead, they use subtle ways to shift energy use. You might not even be aware of it. For example, your air conditioner may run slightly less often. Or your refrigerator might delay it's defrost cycle until the middle of the night. If your utility charges lower rates for electricity at

212

Distinctive Appliances: Order (2014-CE-23020)  

Broader source: Energy.gov [DOE]

DOE ordered Distinctive Appliances Distributing, Inc. to pay a $8,000 civil penalty after finding Distinctive Appliances had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

213

BSH Home Appliances: Order (2014-CE-23013)  

Broader source: Energy.gov [DOE]

DOE ordered BSH Home Appliances Corporation to pay a $12,000 civil penalty after finding BSH Home Appliances had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

214

MC Appliance: Order (2014-CE-20002)  

Broader source: Energy.gov [DOE]

DOE ordered MC Appliance Corporation to pay a $16,000 civil penalty after finding MC Appliance had failed to certify that certain models of residential clothes washers and residential clothes dryers comply with the applicable energy conservation standards.

215

Save Energy on Appliances this Holiday Season  

Office of Energy Efficiency and Renewable Energy (EERE)

Before the holiday shopping mayhem begins, take a look at Energy Saver's tips for finding the most energy efficient appliances.

216

Rebates push sales of efficient appliances  

SciTech Connect (OSTI)

Electric utility appliance-rebate programs can be an effective way to promote improved appliance efficiency. However, rebate values have to be chosen carefully to match the benefits and costs for the two main parties involved: appliance purchasers and ratepayers. 3 tables.

Gorzelnik, E.F.

1984-01-01T23:59:59.000Z

217

Modeling of GE Appliances: Final Presentation  

SciTech Connect (OSTI)

This report is the final in a series of three reports funded by U.S. Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE) in collaboration with GE Appliances through a Cooperative Research and Development Agreement (CRADA) to describe the potential of GE Appliances DR-enabled appliances to provide benefits to the utility grid.

Fuller, Jason C.; Vyakaranam, Bharat; Leistritz, Sean M.; Parker, Graham B.

2013-01-31T23:59:59.000Z

218

Space Heating and Cooling Basics | Department of Energy  

Energy Savers [EERE]

- 1:04pm Addthis A wide variety of technologies are available for heating and cooling homes and other buildings. In addition, many heating and cooling systems have certain...

219

Irregular spacing of heat sources for treating hydrocarbon containing formations  

DOE Patents [OSTI]

A method for treating a hydrocarbon containing formation includes providing heat input to a first section of the formation from one or more heat sources located in the first section. Fluids are produced from the first section through a production well located at or near the center of the first section. The heat sources are configured such that the average heat input per volume of formation in the first section increases with distance from the production well.

Miller, David Scott (Katy, TX); Uwechue, Uzo Philip (Houston, TX)

2012-06-12T23:59:59.000Z

220

Creating and Implementing a Regularized Monitoring and Enforcement System for China's Mandatory Standards and Energy Information Label for Appliances  

E-Print Network [OSTI]

Appliance Manufacturers (AHAM). Typically, the efficiency ofof Home Appliance Manufactures (AHAM); and the Gas Appliance

Lin, Jiang

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

SURVEY OF ADVANCED HEAT PUMP DEVELOPMENTS FOR SPACE CONDITIONING* Phillip D. Fairchild  

E-Print Network [OSTI]

#12;SURVEY OF ADVANCED HEAT PUMP DEVELOPMENTS FOR SPACE CONDITIONING* Phillip D. Fairchild Energy Division Oak Ridge National Laboratory it*~~ ~Oak Ridge, Tennessee ABSTRACT Because of the heat pump energy research organiza- tions. This paper presents a survey of heat pump RD&D projects with special

Oak Ridge National Laboratory

222

HEAT KERNEL AND GREEN FUNCTION ESTIMATES ON NONCOMPACT SYMMETRIC SPACES II  

E-Print Network [OSTI]

HEAT KERNEL AND GREEN FUNCTION ESTIMATES ON NONCOMPACT SYMMETRIC SPACES II Jean­Philippe Anker, Amer. Math. Soc. (2001), 1­9 §1. Introduction For a complete Riemannian manifold, the heat kernel], [BGV] and the references there). Numerous results have been obtained for the heat kernel and Green

Boyer, Edmond

223

HVAC, Water Heating, and Appliance Publications | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

to identify opportunities to reduce the energy consumption of electric motor-driven systems in the residential and commercial sectors through the use of advanced motor...

224

Definition: Smart Appliance | Open Energy Information  

Open Energy Info (EERE)

Appliance Appliance Jump to: navigation, search Dictionary.png Smart Appliance An appliance that includes the intelligence and communications to enable automatic or remote control based on user preferences or external signals from a utility or third party energy service provider. A smart appliance may utilize a Home Area Network to communicate with other devices in the customer's premise, or other channels to communicate with utility systems.[1] Related Terms home area network References ↑ https://www.smartgrid.gov/category/technology/smart_appliance [[C LikeLike UnlikeLike You like this.Sign Up to see what your friends like. ategory: Smart Grid Definitionssmart grid,smart grid, |Template:BASEPAGENAME]]smart grid,smart grid, Retrieved from "http://en.openei.org/w/index.php?title=Definition:Smart_Appliance&oldid=502612

225

Membrane heat pipe development for space radiator applications  

SciTech Connect (OSTI)

A self-deploying membrane heat pipe (SMHP) is being designed and fabricated to operate in an in-cabin experiment aboard a STS flight. The heat pipe comprises a mylar membrane with a woven fabric arterial wick and R-11 as the working fluid. Preliminary results indicate that this SMHP design will successfully expand and retract in response to an applied heat load; the retraction force is provided by a constant force spring.

Woloshun, K.; Merrigan, M.

1986-01-01T23:59:59.000Z

226

Impacts of Imported Liquefied Natural Gas on Residential Appliance Components: Literature Review  

E-Print Network [OSTI]

Appliances. California Energy Commission, PIER Energy-Appliances. California Energy Commission, PIER Energy-Appliances. California Energy Commission, PIER Energy-

Lekov, Alex

2010-01-01T23:59:59.000Z

227

"Table B21. Space-Heating Energy Sources, Floorspace, 1999"  

U.S. Energy Information Administration (EIA) Indexed Site

1. Space-Heating Energy Sources, Floorspace, 1999" 1. Space-Heating Energy Sources, Floorspace, 1999" ,"Total Floorspace (million square feet)" ,"All Buildings","All Buildings with Space Heating","Space-Heating Energy Sources Used (more than one may apply)" ,,,"Electricity","Natural Gas","Fuel Oil","District Heat","Propane","Othera" "All Buildings ................",67338,61612,32291,37902,5611,5534,2728,945 "Building Floorspace" "(Square Feet)" "1,001 to 5,000 ...............",6774,5684,2651,3250,598,"Q",469,"Q" "5,001 to 10,000 ..............",8238,7090,2808,4613,573,"Q",688,"Q" "10,001 to 25,000 .............",11153,9865,5079,6069,773,307,682,"Q"

228

"Table B23. Primary Space-Heating Energy Sources, Floorspace, 1999"  

U.S. Energy Information Administration (EIA) Indexed Site

3. Primary Space-Heating Energy Sources, Floorspace, 1999" 3. Primary Space-Heating Energy Sources, Floorspace, 1999" ,"Total Floorspace (million square feet)" ,"All Buildings","All Buildings with Space Heating","Primary Space-Heating Energy Source Useda" ,,,"Electricity","Natural Gas","Fuel Oil","District Heat" "All Buildings ................",67338,61602,17627,32729,3719,5077 "Building Floorspace" "(Square Feet)" "1,001 to 5,000 ...............",6774,5684,1567,3080,482,"Q" "5,001 to 10,000 ..............",8238,7090,1496,4292,557,"Q" "10,001 to 25,000 .............",11153,9865,3035,5320,597,232 "25,001 to 50,000 .............",9311,8565,2866,4416,486,577

229

The field test and optimization of a solar assisted heat pump system for space heating in extremely cold area  

Science Journals Connector (OSTI)

Abstract As a kind of sustainable energy source, solar energy is becoming highly valued. Especially in extremely cold areas, the amount of energy consumed for space heating is huge, and the conventional coal heating has polluted the environment seriously, therefore solar heating is significant on both energy and environment conservation. In this study, a solar assisted heat pump (SAHP) system was investigated for space heating under extremely cold climatic condition. The system principle and operation modes was presented, and then the project profile and design procedure were introduced, and finally the system performance was evaluated by field test on typical winter days and modeling via TRNSYS simulation environment. The results show that the solar collector efficiency was 51%, and the solar fraction can reach 66% in December. Economic analysis was also performed and the heating expenses for the present SAHP system was 18RMB/m2. Finally, the temperatures of solar energy for both direct heating and storage and only for direct heating (T1A and T1B) were simulated and optimized, which have important significance on the operation time of different operation modes.

Huifang Liu; Yiqiang Jiang; Yang Yao

2014-01-01T23:59:59.000Z

230

Status of European appliance standards  

SciTech Connect (OSTI)

The European Community (EC) recently commissioned a study of the impact of potential appliance standards on electricity consumption in the twelve EC nations. This study looks at refrigerators, freezers, dishwashers, clothes washers, and clothes dryers. The impact of minimum efficiency standards on electricity use over the time period from 1995--2010 is estimated. The results of this study were presented to the EC in September of 1991. Revisions were made to the draft report and final copies sent to all interested parties. The member nations of the EC will soon consider whether they wish to implement uniform energy efficiency standards that would take effect in 1995. The results of the study described above will be presented and the political considerations will be discussed. In addition, data describing the appliance market in Europe will be presented.

Turiel, I. (Lawrence Berkeley Lab., CA (United States)); Lebot, B. (Agence de L'Environnement et de la Maitrise de L'Energie, Valbonne (France))

1992-05-01T23:59:59.000Z

231

Measured Space Conditioning and Water Heating Performance of a Ground-Source Integrated Heat Pump in a Residential Application  

SciTech Connect (OSTI)

In an effort to reduce residential building energy consumption, a ground-source integrated heat pump was developed to meet a home s entire space conditioning and water heating needs, while providing 50% energy savings relative to a baseline suite of minimum efficiency equipment. A prototype 7.0 kW system was installed in a 344 m2 research house with simulated occupancy in Oak Ridge, TN. The equipment was monitored from June 2012 through January 2013.

Munk, Jeffrey D [ORNL] [ORNL; Ally, Moonis Raza [ORNL] [ORNL; Baxter, Van D [ORNL] [ORNL; Gehl, Anthony C [ORNL] [ORNL

2014-01-01T23:59:59.000Z

232

Enhancement of Pool Boiling Heat Transfer in Confined Space  

E-Print Network [OSTI]

Pool boiling is an effective method used in many technical applications for a long time. Its highly efficient heat transfer performance results from not only the convection effect but also the phase change process in pool boiling. Pool boiling...

Hsu, Chia-Hsiang

2014-05-05T23:59:59.000Z

233

GE Appliances and Lighting Home Energy Solutions  

Broader source: Energy.gov (indexed) [DOE]

GE Appliances and Lighting GE Appliances and Lighting Home Energy Solutions Introduction to Devices with Brillion(tm) Technology Portfolio of Products 3 GE Appliances and Lighting All Rights Reserved Brillion(tm) Suite of Home Energy Solutions Nucleus(tm) Smart Meter Other Devices Internet IHD Other Devices PCT Non-Meter Solution GE DRMS GEA Server 4 GE Appliances and Lighting All Rights Reserved Nucleus(tm) energy manager with Brillion(tm) technology Consumers can reduce electric usage by an average of 5% per year. 5 GE Appliances and Lighting All Rights Reserved GE Profile Appliances enabled with Brillion(tm) technology Delayed defrost during peak Delayed starts and temperature adjustments during peak Delayed start until off- peak Reduced energy usage 60%, DR- enabled Reduced wattage during peak When coupled with the Nucleus and a TOU

234

City of Twenty-Nine Palms Space Heating Low Temperature Geothermal Facility  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name City of Twenty-Nine Palms Space Heating Low Temperature Geothermal Facility Facility City of Twenty-Nine Palms Sector Geothermal energy Type Space Heating Location Twenty-Nine Palms, California Coordinates 34.1355582°, -116.0541689° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

235

Hot Lake RV Park Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Park Space Heating Low Temperature Geothermal Facility Park Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Hot Lake RV Park Space Heating Low Temperature Geothermal Facility Facility Hot Lake RV Park Sector Geothermal energy Type Space Heating Location Union County, Oregon Coordinates 45.2334122°, -118.0410627° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

236

Reno-Moana Area (300) Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Reno-Moana Area (300) Space Heating Low Temperature Geothermal Facility Reno-Moana Area (300) Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Reno-Moana Area (300) Space Heating Low Temperature Geothermal Facility Facility Reno-Moana Area (300) Sector Geothermal energy Type Space Heating Location Reno, Nevada Coordinates 39.5296329°, -119.8138027° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

237

Hi-Tech Fisheries Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Hi-Tech Fisheries Space Heating Low Temperature Geothermal Facility Hi-Tech Fisheries Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Hi-Tech Fisheries Space Heating Low Temperature Geothermal Facility Facility Hi-Tech Fisheries Sector Geothermal energy Type Space Heating Location Bluffdale, Utah Coordinates 40.4896711°, -111.9388244° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

238

On Variations of Space-heating Energy Use in Office Buildings  

E-Print Network [OSTI]

CBECS CDD CRB DX EIA EPD EUI HDD HPB IEA IEAD LPD MJ NFRCin energy use intensity (EUI), defined as annual site energycomparing the space-heating EUI from each parametric run to

Lin, Hung-Wen

2014-01-01T23:59:59.000Z

239

Earthjustice, Appliance Standards Awareness Project, Natural...  

Office of Environmental Management (EM)

Council - Comments in response to DOE solicitation of views on the implementation of test procedure waivers for large capacity clothes washers Earthjustice, Appliance Standards...

240

Catalog of DC Appliances and Power Systems  

E-Print Network [OSTI]

Appliance Efficient DC compatible replacement technology variable-speed compressor and fans run by brushless DC motor in place of single-speed compressors

Garbesi, Karina

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Appliance Efficiency Standards and Price Discrimination  

E-Print Network [OSTI]

2: Definition of Energy Efficiency-Based Market Segments/Minimum & ENERGY STAR Standards Market Segment Descriptiondrops. The markets for large energy consuming appliances are

Spurlock, Cecily Anna

2014-01-01T23:59:59.000Z

242

Retrospective Evaluation of Appliance Price Trends  

E-Print Network [OSTI]

the higher the product cost and retail price. Table 3.change and appliance price Room air conditioners Small (price data to clarify price

Dale, Larry

2010-01-01T23:59:59.000Z

243

Smart Domestic Appliances Provide Flexibility for Sustainable...  

Open Energy Info (EERE)

and difficulties associated with smart grid appliances. The presenter discusses demand response and load management and how users of smart grid can benefit renewable energy...

244

Table HC6.5 Space Heating Usage Indicators by Number of Household Members, 2005  

U.S. Energy Information Administration (EIA) Indexed Site

5 Space Heating Usage Indicators by Number of Household Members, 2005 5 Space Heating Usage Indicators by Number of Household Members, 2005 Total U.S. Housing Units.................................. 111.1 30.0 34.8 18.4 15.9 12.0 Do Not Have Heating Equipment..................... 1.2 0.3 0.3 Q 0.2 0.2 Have Space Heating Equipment....................... 109.8 29.7 34.5 18.2 15.6 11.8 Use Space Heating Equipment........................ 109.1 29.5 34.4 18.1 15.5 11.6 Have But Do Not Use Equipment.................... 0.8 Q Q Q Q Q Space Heating Usage During 2005 Heated Floorspace (Square Feet) None............................................................ 3.6 1.0 0.8 0.5 0.5 0.7 1 to 499........................................................ 6.1 3.0 1.6 0.6 0.6 0.3 500 to 999.................................................... 27.7 11.6 8.3 3.6 2.7 1.6 1,000 to 1,499..............................................

245

Solar space heating installed at Kansas City, Kansas. Final report  

SciTech Connect (OSTI)

The solar energy system was constructed with the new 48,800 square feet warehouse to heat the warehouse area of about 39,000 square feet while the auxiliary energy system heats the office area of about 9800 square feet. The building is divided into 20 equal units, and each has its own solar system. The modular design permits the flexibility of combining multiple units to form offices or warehouses of various size floor areas as required by a tenant. Each unit has 20 collectors which are mounted in a single row. The collectors, manufactured by Solaron Corporation, are double glazed flat plate collectors with a gross area of 7800 ft/sup 2/. Air is heated either through the collectors or by the electric resistance duct coils. No freeze protection or storage is required for this system. Extracts from the site files, specifications, drawings, installation, operation and maintenance instructions are included.

Not Available

1981-05-01T23:59:59.000Z

246

Updated Buildings Sector Appliance and Equipment Costs and Efficiency  

U.S. Energy Information Administration (EIA) Indexed Site

Full report (4.1 mb) Full report (4.1 mb) Heating, cooling, & water heating equipment Appendix A - Technology Forecast Updates - Residential and Commercial Building Technologies - Reference Case (1.9 mb) Appendix B - Technology Forecast Updates - Residential and Commercial Building Technologies - Advanced Case (1.3 mb) Lighting and commercial ventilation & refrigeration equipment Appendix C - Technology Forecast Updates - Residential and Commercial Building Technologies - Reference Case (1.1 mb) Appendix D - Technology Forecast Updates - Residential and Commercial Building Technologies - Advanced Case (1.1 mb) Updated Buildings Sector Appliance and Equipment Costs and Efficiency Release date: August 7, 2013 Energy used in the residential and commercial sectors provides a wide range

247

"Table HC15.5 Space Heating Usage Indicators by Four Most Populated States, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

5 Space Heating Usage Indicators by Four Most Populated States, 2005" 5 Space Heating Usage Indicators by Four Most Populated States, 2005" " Million U.S. Housing Units" ,"U.S. Housing Units (millions)","Four Most Populated States" "Space Heating Usage Indicators",,"New York","Florida","Texas","California" "Total U.S. Housing Units",111.1,7.1,7,8,12.1 "Do Not Have Heating Equipment",1.2,"Q","Q","Q",0.2 "Have Space Heating Equipment",109.8,7.1,6.8,7.9,11.9 "Use Space Heating Equipment",109.1,7.1,6.6,7.9,11.4 "Have But Do Not Use Equipment",0.8,"N","Q","N",0.5 "Space Heating Usage During 2005" "Heated Floorspace (Square Feet)"

248

"Table HC10.5 Space Heating Usage Indicators by U.S. Census Region, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

5 Space Heating Usage Indicators by U.S. Census Region, 2005" 5 Space Heating Usage Indicators by U.S. Census Region, 2005" " Million U.S. Housing Units" ,"Housing Units (millions)","U.S. Census Region" "Space Heating Usage Indicators",,"Northeast","Midwest","South","West" "Total U.S. Housing Units",111.1,20.6,25.6,40.7,24.2 "Do Not Have Heating Equipment",1.2,"Q","Q","Q",0.7 "Have Space Heating Equipment",109.8,20.5,25.6,40.3,23.4 "Use Space Heating Equipment",109.1,20.5,25.6,40.1,22.9 "Have But Do Not Use Equipment",0.8,"N","N","Q",0.6 "Space Heating Usage During 2005" "Heated Floorspace (Square Feet)"

249

"Table HC8.5 Space Heating Usage Indicators by Urban/Rural Location, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

5 Space Heating Usage Indicators by Urban/Rural Location, 2005" 5 Space Heating Usage Indicators by Urban/Rural Location, 2005" " Million U.S. Housing Units" ,,"Urban/Rural Location (as Self-Reported)" ,"Housing Units (millions)" "Space Heating Usage Indicators",,"City","Town","Suburbs","Rural" "Total U.S. Housing Units",111.1,47.1,19,22.7,22.3 "Do Not Have Heating Equipment",1.2,0.7,"Q",0.2,"Q" "Have Space Heating Equipment",109.8,46.3,18.9,22.5,22.1 "Use Space Heating Equipment",109.1,45.6,18.8,22.5,22.1 "Have But Do Not Use Equipment",0.8,0.7,"Q","N","N" "Space Heating Usage During 2005" "Heated Floorspace (Square Feet)"

250

Appliance remanufacturing and life cycle energy and economic savings  

E-Print Network [OSTI]

In this paper we evaluate the energy and economic consequences of appliance remanufacturing relative to purchasing new. The appliances presented in this report constitute major residential appliances: refrigerator, dishwasher, ...

Boustani, Avid

251

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Room Air Conditioners Room Air Conditioners Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of residential room air conditioners since 1987. Residential room air conditioners are mounted in windows or through walls and deliver conditioned air to enclosed spaces. Room air conditioners typically extract heat from the room and vent it outdoors. These products are offered in a broad range of sizes and configurations. They are used in homes, apartments, and commercial settings. The standard implemented in 1990 will save approximately 0.7 quads of energy and result in approximately $8 billion in energy bill savings for products shipped from 1990-2019. The standard will avoid about 41.4 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 8.1 million automobiles.

252

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Unit Heaters Unit Heaters Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of unit heaters since 2008. Unit heaters are self-contained fan-type heaters designed to be installed within the heated space, such as rooms, garages, or factory floors. Unit heaters do not include warm air furnaces. The current standard will save approximately 1.3 quads of energy and result in approximately $13.4 billion in energy bill savings for products shipped from 2008-2032. The standard will avoid about 66.8 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 13.1 million automobiles. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information

253

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Commercial Warm Air Furnaces Commercial Warm Air Furnaces Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of commercial warm air furnaces since 1994. Commercial warm air furnaces are self-contained oil-fired or gas-fired furnaces that are designed to supply heated air through ducts to spaces that require it. Commercial warm air furnaces are industrial equipment and have a maximum rated input capacity of 225,000 British thermal units (Btu) an hour or more. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a request for information regarding energy conservation standards for commercial warm air furnaces. 78 FR 25627 (May 2, 2013). For more information, please see the rulemaking webpage.

254

Table HC4.4 Space Heating Characteristics by Renter-Occupied Housing Unit, 2005  

U.S. Energy Information Administration (EIA) Indexed Site

.4 Space Heating Characteristics by Renter-Occupied Housing Unit, 2005 .4 Space Heating Characteristics by Renter-Occupied Housing Unit, 2005 Million U.S. Housing Units Total................................................................ 111.1 33.0 8.0 3.4 5.9 14.4 1.2 Do Not Have Space Heating Equipment....... 1.2 0.6 Q Q Q 0.3 Q Have Main Space Heating Equipment.......... 109.8 32.3 8.0 3.3 5.8 14.1 1.1 Use Main Space Heating Equipment............ 109.1 31.8 8.0 3.2 5.6 13.9 1.1 Have Equipment But Do Not Use It.............. 0.8 0.5 N Q Q Q Q Main Heating Fuel and Equipment Natural Gas.................................................. 58.2 16.4 4.5 2.1 3.2 6.2 0.3 Central Warm-Air Furnace........................ 44.7 10.0 3.3 1.4 1.6 3.3 0.3 For One Housing Unit........................... 42.9 8.6 3.3 1.2 1.4 2.4 0.3 For Two Housing Units..........................

255

Table HC6.4 Space Heating Characteristics by Number of Household Members, 2005  

U.S. Energy Information Administration (EIA) Indexed Site

4 Space Heating Characteristics by Number of Household Members, 2005 4 Space Heating Characteristics by Number of Household Members, 2005 Total..................................................................... 111.1 30.0 34.8 18.4 15.9 12.0 Do Not Have Space Heating Equipment............ 1.2 0.3 0.3 Q 0.2 0.2 Have Main Space Heating Equipment............... 109.8 29.7 34.5 18.2 15.6 11.8 Use Main Space Heating Equipment................. 109.1 29.5 34.4 18.1 15.5 11.6 Have Equipment But Do Not Use It................... 0.8 Q Q Q Q Q Main Heating Fuel and Equipment Natural Gas....................................................... 58.2 15.6 18.0 9.5 8.4 6.7 Central Warm-Air Furnace............................. 44.7 10.7 14.3 7.6 6.9 5.2 For One Housing Unit................................ 42.9 10.1 13.8 7.3 6.5 5.2 For Two Housing Units...............................

256

Table HC3.4 Space Heating Characteristics by Owner-Occupied Housing Unit, 2005  

U.S. Energy Information Administration (EIA) Indexed Site

.4 Space Heating Characteristics by Owner-Occupied Housing Unit, 2005 .4 Space Heating Characteristics by Owner-Occupied Housing Unit, 2005 Million U.S. Housing Units Total................................................................ 111.1 78.1 64.1 4.2 1.8 2.3 5.7 Do Not Have Space Heating Equipment....... 1.2 0.6 0.3 N Q Q Q Have Main Space Heating Equipment.......... 109.8 77.5 63.7 4.2 1.8 2.2 5.6 Use Main Space Heating Equipment............ 109.1 77.2 63.6 4.2 1.8 2.1 5.6 Have Equipment But Do Not Use It.............. 0.8 0.3 Q N Q Q Q Main Heating Fuel and Equipment Natural Gas.................................................. 58.2 41.8 35.3 2.8 1.2 1.0 1.6 Central Warm-Air Furnace........................ 44.7 34.8 29.7 2.3 0.7 0.6 1.4 For One Housing Unit........................... 42.9 34.3 29.5 2.3 0.6 0.6 1.4 For Two Housing Units..........................

257

Building Technologies Office: About the Appliance and Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

About the Appliance and About the Appliance and Equipment Standards Program to someone by E-mail Share Building Technologies Office: About the Appliance and Equipment Standards Program on Facebook Tweet about Building Technologies Office: About the Appliance and Equipment Standards Program on Twitter Bookmark Building Technologies Office: About the Appliance and Equipment Standards Program on Google Bookmark Building Technologies Office: About the Appliance and Equipment Standards Program on Delicious Rank Building Technologies Office: About the Appliance and Equipment Standards Program on Digg Find More places to share Building Technologies Office: About the Appliance and Equipment Standards Program on AddThis.com... About History & Impacts Statutory Authorities & Rules Regulatory Processes

258

How Much Are Your Appliances and Electronics Costing You? | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Appliance and Home Electronic Energy Use page to calculate the electricity consumption of your appliances in preparation for the EnergyFaceoff campaign in November. As...

259

ENERGY STAR Appliance Verification Testing - Pilot Program Summary...  

Broader source: Energy.gov (indexed) [DOE]

Appliance Verification Testing - Pilot Program Summary Report dated February 3, 2012 ENERGY STAR Appliance Verification Testing - Pilot Program Summary Report dated February 3,...

260

Sales Tax Holiday for Energy-Efficient Appliances  

Broader source: Energy.gov [DOE]

In November 2007, Maryland enacted legislation creating a sales and use tax "holiday" for certain energy-efficient appliances, beginning in 2011. Under the law, qualifying appliances purchased...

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

"Table HC15.4 Space Heating Characteristics by Four Most Populated States, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

4 Space Heating Characteristics by Four Most Populated States, 2005" 4 Space Heating Characteristics by Four Most Populated States, 2005" " Million U.S. Housing Units" ,"Housing Units (millions)","Four Most Populated States" "Space Heating Characteristics",,"New York","Florida","Texas","California" "Total",111.1,7.1,7,8,12.1 "Do Not Have Space Heating Equipment",1.2,"Q","Q","Q",0.2 "Have Main Space Heating Equipment",109.8,7.1,6.8,7.9,11.9 "Use Main Space Heating Equipment",109.1,7.1,6.6,7.9,11.4 "Have Equipment But Do Not Use It",0.8,"N","Q","N",0.5 "Main Heating Fuel and Equipment" "Natural Gas",58.2,3.8,0.4,3.8,8.4

262

"Table HC11.5 Space Heating Usage Indicators by Northeast Census Region, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

5 Space Heating Usage Indicators by Northeast Census Region, 2005" 5 Space Heating Usage Indicators by Northeast Census Region, 2005" " Million U.S. Housing Units" ,,"Northeast Census Region" ,"U.S. Housing Units (millions)" ,,,"Census Division" ,,"Total Northeast" "Space Heating Usage Indicators",,,"Middle Atlantic","New England" "Total U.S. Housing Units",111.1,20.6,15.1,5.5 "Do Not Have Heating Equipment",1.2,"Q","Q","Q" "Have Space Heating Equipment",109.8,20.5,15.1,5.4 "Use Space Heating Equipment",109.1,20.5,15.1,5.4 "Have But Do Not Use Equipment",0.8,"N","N","N" "Space Heating Usage During 2005"

263

"Table HC10.4 Space Heating Characteristics by U.S. Census Region, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

4 Space Heating Characteristics by U.S. Census Region, 2005" 4 Space Heating Characteristics by U.S. Census Region, 2005" " Million U.S. Housing Units" ,"Housing Units (millions)","U.S. Census Region" "Space Heating Characteristics",,"Northeast","Midwest","South","West" "Total",111.1,20.6,25.6,40.7,24.2 "Do Not Have Space Heating Equipment",1.2,"Q","Q","Q",0.7 "Have Main Space Heating Equipment",109.8,20.5,25.6,40.3,23.4 "Use Main Space Heating Equipment",109.1,20.5,25.6,40.1,22.9 "Have Equipment But Do Not Use It",0.8,"N","N","Q",0.6 "Main Heating Fuel and Equipment" "Natural Gas",58.2,11.4,18.4,13.6,14.7

264

"Table HC12.5 Space Heating Usage Indicators by Midwest Census Region, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

5 Space Heating Usage Indicators by Midwest Census Region, 2005" 5 Space Heating Usage Indicators by Midwest Census Region, 2005" " Million U.S. Housing Units" ,,"Midwest Census Region" ,"U.S. Housing Units (millions)" ,,,"Census Division" ,,"Total Midwest" "Space Heating Usage Indicators",,,"East North Central","West North Central" "Total U.S. Housing Units",111.1,25.6,17.7,7.9 "Do Not Have Heating Equipment",1.2,"Q","Q","N" "Have Space Heating Equipment",109.8,25.6,17.7,7.9 "Use Space Heating Equipment",109.1,25.6,17.7,7.9 "Have But Do Not Use Equipment",0.8,"N","N","N" "Space Heating Usage During 2005"

265

Heat kernels on metric spaces with doubling Alexander Grigor'yan, Jiaxin Hu and Ka-Sing Lau  

E-Print Network [OSTI]

Heat kernels on metric spaces with doubling measure Alexander Grigor'yan, Jiaxin Hu and Ka-Sing Lau Abstract. In this survey we discuss heat kernel estimates of self-similar type on metric spaces with doubling measures. We characterize the tail functions from heat kernel estimates in both non

Hu, Jiaxin

266

Heat kernels on metric spaces with doubling measure Alexander Grigor'yan, Jiaxin Hu and Ka-Sing Lau  

E-Print Network [OSTI]

Heat kernels on metric spaces with doubling measure Alexander Grigor'yan, Jiaxin Hu and Ka-Sing Lau Abstract. In this survey we discuss heat kernel estimates of self-similar type on metric spaces with doubling measures. We characterize the tail functions from heat kernel estimates in both non

Grigor'yan, Alexander

267

Appliance and Equipment Standards Program  

Broader source: Energy.gov [DOE]

The Building Technologies Office (BTO) implements minimum energy conservation standards for more than 50 categories of appliances and equipment. As a result of these standards, energy users saved about $55 billion on their utility bills in 2013. Since the beginning of 2009, 25 new or updated standards have been issued, which will help increase annual savings by more than 50 percent over the next decade. By 2030, cumulative operating cost savings from all standards in effect since 1987 will reach over $1.7 trillion, with a cumulative reduction of 6.8 billion tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of 1.4 billion automobiles. Products covered by standards represent about 90% of home energy use, 60% of commercial building use, and 29% of industrial energy us

268

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Residential Refrigerators and Freezers Residential Refrigerators and Freezers Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy's (DOE) energy conservation standards for residential refrigerators and freezers since 1990. Residential refrigerators and freezers include refrigerators, refrigerator-freezers, and freezers, such as standard-size residential units as well as compact units used in offices and dormitory rooms. Known collectively as "refrigeration products," these appliances chill and preserve food and beverages, provide ice and chilled water, and freeze food. The standard implemented in 1990 will save approximately 5.6 quads of energy and result in approximately $61.7 billion in energy bill savings for products shipped from 1990-2019. The standard will avoid about 312.4 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 61.3 million automobiles.

269

Solar space and water heating system at Stanford University Central Food Services Building. Final report  

SciTech Connect (OSTI)

This active hydronic domestic hot water and space heating system was 840 ft/sup 2/ of single-glazed, liquid, flat plate collectors and 1550 gal heat storage tanks. The following are discussed: energy conservation, design philosophy, operation, acceptance testing, performance data, collector selection, bidding, costs, economics, problems, and recommendations. An operation and maintenance manual and as-built drawings are included in appendices. (MHR)

Not Available

1980-05-01T23:59:59.000Z

270

Building Technologies Office: Cold Climate Heat Pump Research Project  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Cold Climate Heat Pump Cold Climate Heat Pump Research Project to someone by E-mail Share Building Technologies Office: Cold Climate Heat Pump Research Project on Facebook Tweet about Building Technologies Office: Cold Climate Heat Pump Research Project on Twitter Bookmark Building Technologies Office: Cold Climate Heat Pump Research Project on Google Bookmark Building Technologies Office: Cold Climate Heat Pump Research Project on Delicious Rank Building Technologies Office: Cold Climate Heat Pump Research Project on Digg Find More places to share Building Technologies Office: Cold Climate Heat Pump Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research Windows, Skylights, & Doors Research Space Heating & Cooling Research

271

Application analysis of ground source heat pumps in building space conditioning  

SciTech Connect (OSTI)

The adoption of geothermal energy in space conditioning of buildings through utilizing ground source heat pump (GSHP, also known as geothermal heat pump) has increased rapidly during the past several decades. However, the impacts of the GSHP utilization on the efficiency of heat pumps and soil temperature distribution remained unclear and needs further investigation. This paper presents a novel model to calculate the soil temperature distribution and the coefficient of performance (COP) of GSHP. Different scenarios were simulated to quantify the impact of different factors on the GSHP performance, including heat balance, daily running mode, and spacing between boreholes. Our results show that GSHP is suitable for buildings with balanced cooling and heating loads. It can keep soil temperature at a relatively constant level for more than 10 years. Long boreholes, additional space between boreholes, intermittent running mode will improve the performance of GSHP, but large initial investment is required. The improper design will make the COP of GSHP even lower than traditional heat pumps. Professional design and maintenance technologies are greatly needed in order to promote this promising technology in the developing world.

Qian, Hua; Wang, Yungang

2013-07-01T23:59:59.000Z

272

Appliances and Commercial Equipment Standards: Guidance  

Broader source: Energy.gov (indexed) [DOE]

Office Office HOME ABOUT ENERGY EFFICIENT TECHNOLOGIES RESIDENTIAL BUILDINGS COMMERCIAL BUILDINGS APPLIANCE & EQUIPMENT STANDARDS BUILDING ENERGY CODES EERE » Building Technologies Office » Appliances & Equipment Standards About Standards & Test Procedures Implementation, Certification & Enforcement Rulemakings & Notices Further Guidance ENERGY STAR® Guidance and Frequently Asked Questions This webpage is designed to provide guidance and answer Frequently Asked Questions (FAQs) on the U.S. Department of Energy's appliance standards program. Guidance types span all covered products and covered equipment and cover such topics as: definitions, scope of coverage, conservation standards, test procedures, certification, Compliance and Certification Management System (CCMS), and enforcement. This website offers users an

273

Appliance Standards and Rulemaking Federal Advisory Committee Charter  

Broader source: Energy.gov (indexed) [DOE]

APPLIANCE STANDARDS AND RULEMAKING APPLIANCE STANDARDS AND RULEMAKING FEDERAL ADVISORY COMMITTEE (ASRAC) U.S. DEPARTMENT OF ENERGY Federal Advisory Committee Charter 1. Committee's Official Designation: Appliance Standards and Rulemaking Federal Advisory Committee (ASRAC) 2. Authority: This charter establishes the Appliance Standards and Rulemaking Federal Advisory Committee under the authority of the Department of Energy (DOE). The Committee is being amended

274

Heat pipe cooled reactors for multi-kilowatt space power supplies  

SciTech Connect (OSTI)

Three nuclear reactor space power system designs are described that demonstrate how the use of high temperature heat pipes for reactor heat transport, combined with direct conversion of heat to electricity, can result in eliminating pumped heat transport loops for both primary reactor cooling and heat rejection. The result is a significant reduction in system complexity that leads to very low mass systems with high reliability, especially in the power range of 1 to 20 kWe. In addition to removing heat exchangers, electromagnetic pumps, and coolant expansion chambers, the heat pipe/direct conversion combination provides such capabilities as startup from the frozen state, automatic rejection of reactor decay heat in the event of emergency or accidental reactor shutdown, and the elimination of single point failures in the reactor cooling system. The power system designs described include a thermoelectric system that can produce 1 to 2 kWe, a bimodal modification of this system to increase its power level to 5 kWe and incorporate high temperature hydrogen propulsion capability, and a moderated thermionic reactor concept with 5 to 20 kWe power output that is based on beryllium modules that thermally couple cylindrical thermionic fuel elements (TFEs) to radiator heat pipes.

Ranken, W.A.; Houts, M.G.

1995-01-01T23:59:59.000Z

275

Building Technologies Program: History of Federal Appliance Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

History of Federal History of Federal Appliance Standards to someone by E-mail Share Building Technologies Program: History of Federal Appliance Standards on Facebook Tweet about Building Technologies Program: History of Federal Appliance Standards on Twitter Bookmark Building Technologies Program: History of Federal Appliance Standards on Google Bookmark Building Technologies Program: History of Federal Appliance Standards on Delicious Rank Building Technologies Program: History of Federal Appliance Standards on Digg Find More places to share Building Technologies Program: History of Federal Appliance Standards on AddThis.com... About Standards & Test Procedures Implementation, Certification & Enforcement Rulemakings & Notices Further Guidance ENERGY STAR® Popular Links

276

Appliance Energy Consumption in Australia | Open Energy Information  

Open Energy Info (EERE)

Appliance Energy Consumption in Australia Appliance Energy Consumption in Australia Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Appliance Energy Consumption in Australia Focus Area: Appliances & Equipment Topics: Policy Impacts Website: www.energyrating.gov.au/resources/program-publications/?viewPublicatio Equivalent URI: cleanenergysolutions.org/content/appliance-energy-consumption-australi DeploymentPrograms: Industry Codes & Standards Regulations: Appliance & Equipment Standards and Required Labeling The document sets out the equations necessary to calculate the star rating index for appliances that carry an energy label in Australia. Equations for new air conditioner and refrigerator algorithms from April 2010 are included. Televisions, which have carried a mandatory energy label from

277

Analysis of selected surface characteristics and latent heat storage for passive solar space heating  

SciTech Connect (OSTI)

Results are presented of an analysis of the value of various technical improvements in the solar collector and thermal storage subsystems of passive solar residential, agricultural, and industrial systems for two regions of the country. The evaluated improvements are: decreased emissivity and increased absorptivity of absorbing surfaces, decreased reflectivity, and decreased emissivity of glazing surface, and the substitution of sensible heat storage media with phase change materials. The value of each improvement is estimated by the additional energy savings resulting from the improvement.

Fthenakis, V.; Leigh, R.

1981-12-01T23:59:59.000Z

278

DOE Solar Decathlon: News Blog » Appliances  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

'Appliances' 'Appliances' New Contest Data Displays Provide Insight into Competition Scoring Saturday, October 5, 2013 By Solar Decathlon New contest data displays are now available on the U.S. Department of Energy Solar Decathlon website. If you are interested in the real-time performance of each house and want to keep a close eye on the competition, check out the Contests section pages. In the Contests section, the pages for the measured contests (Comfort Zone, Hot Water, Appliances, Home Entertainment, and Energy Balance) explain the contest requirements and provide real-time graphical displays of the accumulated measurements/scores for each team. Roll your cursor over the graphics to see more detailed information about each contest. For example, in the Appliances Contest graphic, the scores for running the refrigerator,

279

Appliance Energy Efficiency Standards | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Energy Efficiency Standards Energy Efficiency Standards Appliance Energy Efficiency Standards < Back Program Info State Maryland Program Type Appliance/Equipment Efficiency Standards Provider Maryland Energy Administration '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for

280

DOE Solar Decathlon: News Blog » Appliances  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Appliances Appliances Below you will find Solar Decathlon news from the Appliances archive, sorted by date. New Contest Data Displays Provide Insight into Competition Scoring Saturday, October 5, 2013 By Solar Decathlon New contest data displays are now available on the U.S. Department of Energy Solar Decathlon website. If you are interested in the real-time performance of each house and want to keep a close eye on the competition, check out the Contests section pages. In the Contests section, the pages for the measured contests (Comfort Zone, Hot Water, Appliances, Home Entertainment, and Energy Balance) explain the contest requirements and provide real-time graphical displays of the accumulated measurements/scores for each team. Roll your cursor over the graphics to see more detailed information about each contest. For example,

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Research & Development Roadmap: Next-Generation Appliances  

Broader source: Energy.gov [DOE]

The Research and Development (R&D) Roadmap for Next-Generation Appliances provides recommendations to the Building Technologies Office (BTO) on R&D activities to pursue that will aid in achieving BTOs energy savings goals.

282

Association of Home Appliance Manufacturers Comment  

Broader source: Energy.gov [DOE]

The Association of Home Appliance Manufacturers (AHAM) respectfully submits the following comments to the Department of Energy (DOE) on its Regulatory Burden RFI, 79 Fed. Reg. 37963 (July 3, 2014).

283

Equator Appliance: ENERGY STAR Referral (EZ 3720)  

Broader source: Energy.gov [DOE]

DOE referred Equator Appliance clothes washer EZ 3720 to EPA, brand manager of the ENERGY STAR program, for appropriate action after DOE testing revealed that the model does not meet ENERGY STAR requirements.

284

Appliance Efficiency Regulations | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Efficiency Regulations Efficiency Regulations Appliance Efficiency Regulations < Back Program Info State California Program Type Appliance/Equipment Efficiency Standards Provider California Energy Commission '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for which the federal government is not currently developing an efficiency

285

"Table HC4.4 Space Heating Characteristics by Renter-Occupied...  

U.S. Energy Information Administration (EIA) Indexed Site

Characteristics",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,33,8,3.4,5.9,14.4,1.2 "Do Not Have Space Heating Equipment",1.2,0.6,"Q"...

286

Load control in low voltage level of the electricity grid using CHP appliances  

E-Print Network [OSTI]

as a Virtual Power Plant to the electricity grid. In this work we focus on different algorithms to control is centrally generated in large power plants and in which distribution means distribution from these power.g.c.bosman@utwente.nl Abstract--The introduction of µCHP (Combined Heat and Power) appliances and other means of distributed

Al Hanbali, Ahmad

287

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Single Package Vertical Air Conditioners and Heat Pumps Single Package Vertical Air Conditioners and Heat Pumps Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy's energy conservation standards for single package vertical air conditioners and heat pumps as a separate equipment class since 2008. Before 2010, this equipment was regulated under the broader scope of commercial air conditioning and heating equipment. Single package vertical air conditioners and heat pumps are commercial air conditioning and heating equipment with its main components arranged in a vertical fashion. They are mainly used in modular classrooms, modular office buildings, telecom shelters, and hotels, and are typically installed on the outside of an exterior wall or in a closet against an exterior wall but inside the building.

288

Appliance/Equipment Efficiency Standards | Open Energy Information  

Open Energy Info (EERE)

Appliance/Equipment Efficiency Standards Appliance/Equipment Efficiency Standards Jump to: navigation, search Many states have established minimum efficiency standards for certain appliances and equipment. In these states, the retail sale of appliances and equipment that do not meet the established standards is prohibited. The federal government has also established efficiency standards for certain appliances and equipment. When both the federal government and a state have adopted efficiency standards for the same type of appliance or equipment, the federal standard overrides the state standard even if the state standard is stricter. [1] Appliance/Equipment Efficiency Standards Incentives CSV (rows 1 - 14) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Appliance Efficiency Regulations (California) Appliance/Equipment Efficiency Standards California Yes

289

Heat Transfer -1 A satellite in space orbits the sun. The satellite can be approximated as a flat plate with  

E-Print Network [OSTI]

Heat Transfer - 1 A satellite in space orbits the sun. The satellite can be approximated as a flat plate with dimensions and properties given below. (a) Calculate the solar heat flux (W/m2 is at a distance where the solar heat flux (as defined above) is 500 W/m2 , and the flat plate is oriented

Virginia Tech

290

"Table HC3.4 Space Heating Characteristics by Owner-Occupied Housing Unit, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

4 Space Heating Characteristics by Owner-Occupied Housing Unit, 2005" 4 Space Heating Characteristics by Owner-Occupied Housing Unit, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ," Housing Units (millions)" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Space Heating Characteristics",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Do Not Have Space Heating Equipment",1.2,0.6,0.3,"N","Q","Q","Q" "Have Main Space Heating Equipment",109.8,77.5,63.7,4.2,1.8,2.2,5.6

291

Potential of thermal insulation and solar thermal energy in domestic hot water and space heating and cooling sectors in Lebanon in the period 2010 - 2030.  

E-Print Network [OSTI]

??The potential of thermal insulation and solar thermal energy in domestic water heating, space heating and cooling in residential and commercial buildings Lebanon is studied (more)

Zaatari, Z.A.R.

2012-01-01T23:59:59.000Z

292

GE Appliance Park Louisville, KY Plant Wide Assessment Final Report October 25th, 2007  

SciTech Connect (OSTI)

Used a team of experts to analyze and model major systems at a large industrial appliance manufacturer. During the data gathering stage, the team specifically looked for baselining the efficiency of the systems as well as developing short term and longer term efficiency projects. Electrical distribution, Compressed air generation and thermal heat recovery for the production facility and front office heating and cooling optimization were all baselined during the study.

Chandon Rao; Richard Urschel

2007-10-25T23:59:59.000Z

293

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Direct Heating Equipment and Pool Heaters Active Mode Test Procedures Direct Heating Equipment and Pool Heaters Active Mode Test Procedures Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is proposing to amend the active mode test procedures for direct heating equipment and pool heaters. This rulemaking is mandated by the Energy Policy and Conservation Act (EPCA). Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of proposed rulemaking regarding active mode test procedures for direct heating equipment and pool heaters. 78 FR 63410 (October 24, 2013). The comment deadline is January 7, 2014. Public Meeting Information

294

Issues in federal preemption of state appliance energy efficiency regulations  

SciTech Connect (OSTI)

The findings and conclusions of the analysis of the various issues involved in the federal preemption of state regulations for the DOE no standard rule on covered appliances are summarized. The covered products are: refrigerators, refrigerator-freezers, freezers, clothes dryers, kitchen ranges and ovens, water heaters (excluding heat pump water heaters), room air conditioners, central air conditioners (excluding heat pumps), and furnaces. A detailed discussion of the rationale for the positions of groups offering comment for the record is presneted. The pertinent categories of state and local regulations and programs are explained, then detailed analysis is conducted on the covered products and regulations. Issues relating to the timing of preemption of state regulations are discussed, as well as issues relating to burden of proof, contents of petitions for exemptions from preemption, criteria for evaluating petitions, and procedural and other issues. (LEW)

Fang, J.M.; Balistocky, S.; Schaefler, A.M.

1982-12-01T23:59:59.000Z

295

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Residential Furnaces and Boilers Residential Furnaces and Boilers Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of residential furnaces and boilers since 1987. Residential furnaces and boilers include gas, electric, and oil-fired furnaces and boilers that are used to provide central heating to residential dwellings. Furnaces heat air and distribute the heated air through the house using ducts. Boilers heat water, providing either hot water or steam for heating. Steam is distributed via pipes to steam radiators, and hot water can either be distributed via baseboard radiators, radiant floor systems, or can heat air via a coil. The standards for residential furnaces and boilers implemented in 1992 will save approximately 3.9 quads of energy and result in approximately $46.2 billion in energy bill savings for products shipped from 1992-2021. The standard will avoid about 206 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 40.4 million automobiles.

296

Expert Meeting Report: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems  

SciTech Connect (OSTI)

The topic of this meeting was 'Recommendations For Applying Water Heaters In Combination Space And Domestic Water Heating Systems.' Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic. The meeting was held at the Westford Regency Hotel, in Westford, Massachusetts on 7/31/2011.

Rudd, A.; Ueno, K.; Bergey, D.; Osser, R.

2012-07-01T23:59:59.000Z

297

"Table HC4.5 Space Heating Usage Indicators by Renter-Occupied Housing Unit, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

5 Space Heating Usage Indicators by Renter-Occupied Housing Unit, 2005" 5 Space Heating Usage Indicators by Renter-Occupied Housing Unit, 2005" " Million U.S. Housing Units" ,," Renter-Occupied Housing Units (millions)","Type of Renter-Occupied Housing Unit" ," Housing Units (millions)" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Space Heating Usage Indicators",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total U.S. Housing Units",111.1,33,8,3.4,5.9,14.4,1.2 "Do Not Have Heating Equipment",1.2,0.6,"Q","Q","Q",0.3,"Q" "Have Space Heating Equipment",109.8,32.3,8,3.3,5.8,14.1,1.1

298

"Table HC3.5 Space Heating Usage Indicators by Owner-Occupied Housing Unit, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

5 Space Heating Usage Indicators by Owner-Occupied Housing Unit, 2005" 5 Space Heating Usage Indicators by Owner-Occupied Housing Unit, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ," Housing Units (millions)" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Space Heating Usage Indicators",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total U.S. Housing Units",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Do Not Have Heating Equipment",1.2,0.6,0.3,"N","Q","Q","Q" "Have Space Heating Equipment",109.8,77.5,63.7,4.2,1.8,2.2,5.6

299

"Table B27. Space Heating Energy Sources, Floorspace for Non-Mall Buildings, 2003"  

U.S. Energy Information Administration (EIA) Indexed Site

7. Space Heating Energy Sources, Floorspace for Non-Mall Buildings, 2003" 7. Space Heating Energy Sources, Floorspace for Non-Mall Buildings, 2003" ,"Total Floorspace (million square feet)" ,"All Buildings*","Buildings with Space Heating","Space-Heating Energy Sources Used (more than one may apply)" ,,,"Elec- tricity","Natural Gas","Fuel Oil","District Heat","Propane","Other a" "All Buildings* ...............",64783,60028,28600,36959,5988,5198,3204,842 "Building Floorspace" "(Square Feet)" "1,001 to 5,000 ...............",6789,5668,2367,2829,557,"Q",665,183 "5,001 to 10,000 ..............",6585,5786,2560,3358,626,"Q",529,"Q" "10,001 to 25,000 .............",11535,10387,4872,6407,730,289,597,"Q"

300

"Table B29. Primary Space-Heating Energy Sources, Total Floorspace for Non-Mall Buildings, 2003"  

U.S. Energy Information Administration (EIA) Indexed Site

9. Primary Space-Heating Energy Sources, Total Floorspace for Non-Mall Buildings, 2003" 9. Primary Space-Heating Energy Sources, Total Floorspace for Non-Mall Buildings, 2003" ,"Total Floorspace (million square feet)" ,"All Buildings*","Buildings with Space Heating","Primary Space-Heating Energy Source Used a" ,,,"Electricity","Natural Gas","Fuel Oil","District Heat" "All Buildings* ...............",64783,60028,15996,32970,3818,4907 "Building Floorspace" "(Square Feet)" "1,001 to 5,000 ...............",6789,5668,1779,2672,484,"Q" "5,001 to 10,000 ..............",6585,5786,1686,3068,428,"Q" "10,001 to 25,000 .............",11535,10387,3366,5807,536,"Q" "25,001 to 50,000 .............",8668,8060,2264,4974,300,325

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Econometric model of the joint production and consumption of residential space heat  

SciTech Connect (OSTI)

This study models the production and comsumption of residential space heat, a nonmarket good. Production reflects capital investment decisions of households; consumption reflects final demand decisions given the existing capital stock. In the model, the production relationship is represented by a translog cost equation and an anergy factor share equation. Consumption is represented by a log-linear demand equation. This system of three equations - cost, fuel share, and final demand - is estimated simultaneously. Results are presented for two cross-sections of households surveyed in 1973 and 1981. Estimates of own-price and cross-price elasticities of factor demand are of the correct sign, and less than one in magnitude. The price elasticity of final demand is about -0.4; the income elasticity of final demand is less than 0.1. Short-run and long-run elasticities of demand for energy are about -0.3 and -0.6, respectively. These results suggest that price-induced decreases in the use of energy for space heat are attributable equally to changes in final demand and to energy conservation, the substitution of capital for energy in the production of space heat. The model is used to simulate the behavior of poor and nonpoor households during a period of rising energy prices. This simulation illustrates the greater impact of rising prices on poor households.

Klein, Y.L.

1985-12-01T23:59:59.000Z

302

Catalog of DC Appliances and Power Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Catalog of DC Appliances and Power Systems Catalog of DC Appliances and Power Systems Title Catalog of DC Appliances and Power Systems Publication Type Report LBNL Report Number LBNL-5364E Year of Publication 2011 Authors Garbesi, Karina, Vagelis Vossos, and Hongxia Shen Document Number LBNL-5364E Date Published October Publisher Lawrence Berkeley National Laboratory Abstract This document catalogs the characteristics of current and potential future direct current (DC) products and power systems. It is part of a larger U.S. Department of Energy-funded project, "Direct-DC Power Systems for Energy Efficiency and Renewable Energy Integration with a Residential and Small Commercial Focus". That project is investigating the energy-savings potential, benefits, and barriers of using DC generated by on-site renewable energy systems directly in its DC form, rather than converting it first to alternating current (AC) for distribution to loads. Two related reports resulted from this work: this Catalog and a companion report that addresses direct-DC energy savings in U.S. residential buildings.Interest in 'direct-DC' is motivated by a combination of factors: the very rapid increase in residential and commercial photovoltaic (PV) power systems in the United States; the rapid expansion in the current and expected future use of energy efficient products that utilize DC power internally; the demonstrated energy savings of direct-DC in commercial data centers; and the current emergence of direct-DC power standards and products designed for grid-connected residential and commercial products. Based on an in-depth study of DC appliances and power systems, we assessed off-grid markets for DC appliances, the DC compatibility of mainstream electricity end-uses, and the emerging mainstream market for direct-DC appliances and power systems.

303

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Residential Central Air Conditioners and Heat Pumps Test Procedure Residential Central Air Conditioners and Heat Pumps Test Procedure Sign up for e-mail updates on regulations for this and other products DOE is conducting a rulemaking to revise the test procedures for residential central air conditioners and heat pumps. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a supplemental notice of proposed rulemaking regarding test procedures for residential central air conditioners and heat pumps. 76 FR 65616 (Oct. 24, 2011). Public Meeting Information No public meeting is scheduled at this time. Submitting Public Comments The comment period is closed. Milestones and Documents The residential central air conditioners and heat pumps test procedure rulemaking docket EERE-2009-BT-TP-0004 contains all notices, public comments, public meeting transcripts, and supporting documents. For the latest information on the planned timing of future DOE regulatory milestones, see the current Office of Management and Budget Unified Agenda of Regulatory and Deregulatory Actions. All planned dates are preliminary and subject to change.

304

Four-County EMC - Residential Energy Efficiency Appliance Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

Four-County EMC - Residential Energy Efficiency Appliance Rebate Four-County EMC - Residential Energy Efficiency Appliance Rebate Program Four-County EMC - Residential Energy Efficiency Appliance Rebate Program < Back Eligibility Residential Savings Category Appliances & Electronics Program Info State North Carolina Program Type Utility Rebate Program Rebate Amount Clothes Washer: $50 Dishwasher: $50 Refrigerator: $50 Freezer: $50 Refrigerator/Freezer Recycling: $50 Provider Four County EMC Four-County EMC offers its customers $50 rebates for purchasing certain Energy Star appliances. Eligible appliances include refrigerators, dishwashers, clothes washers and freezers. The rebates are available to residential customers who are replacing older appliances or buying new appliances for the first time. In order to qualify for the rebate, Energy

305

Nebraska Appliance Rebate Program opens | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Nebraska Appliance Rebate Program opens Nebraska Appliance Rebate Program opens July 12, 2010 - 4:00pm Addthis Lindsay Gsell Nearly 500 people lined up outside of Omaha's Nebraska...

306

Microwave vs. Electric Kettle: Which Appliance Is in Hot Water...  

Energy Savers [EERE]

Microwave vs. Electric Kettle: Which Appliance Is in Hot Water in EnergyFaceoff Round 4? Microwave vs. Electric Kettle: Which Appliance Is in Hot Water in EnergyFaceoff Round 4?...

307

Analysis of Potential Energy Saving and CO2 Emission Reduction of Home Appliances and Commercial Equipments in China  

E-Print Network [OSTI]

appliances (excluding motors, transformers, and air compressors)appliances (excluding motors, transformers, and air compressors)

Zhou, Nan

2010-01-01T23:59:59.000Z

308

Analysis of Potential Energy Saving and CO2 Emission Reduction of Home Appliances and Commercial Equipments in China  

E-Print Network [OSTI]

appliances (excluding motors, transformers, and air compressors)appliances (excluding motors, transformers, and air compressors)

Zhou, Nan

2011-01-01T23:59:59.000Z

309

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Residential Water Heaters Residential Water Heaters Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy (DOE) energy conservation standards for residential water heaters since 1990. Residential water heaters are products that utilize oil, gas, or electricity to heat potable water for use upon demand for activities such as washing dishes or clothes, or bathing. Residential water heaters include storage type units that store heated water in an insulated tank and instantaneous type units that heat water on demand. The standard mandatory in 1990 will save approximately 3.2 quads of energy and result in approximately $34.8 billion in energy bill savings for products shipped from 1990-2019. The standard will avoid about 180 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 35.3 million automobiles.

310

Appliance Standards Update and Review of Certification, Compliance and Enforcement Powerpoint Presentation for ASHRAE Conference, January 31, 2011  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Buildings Regulatory Program Buildings Regulatory Program Buildings Regulatory Program Appliance Standards Update and Review of Certification, Compliance and Enforcement John Cymbalsky, Ashley Armstrong, and Laura Barhydt US Department of Energy January 31, 2011 Presentation Outline Presentation Outline * Upcoming Relevant Rulemakings * Changes to Rulemaking Process * Executive Order 13563 * Overview of Compliance, Certification, and Enforcement * Detailed Questions and Answers 2 | U.S. Department of Energy energy.gov Long Term Schedules for Certain HVAC Rulemakings Long Term Schedules for Certain HVAC Rulemakings Appliance Standards Product Categories Driver Approx. Rule Initiation Date Final Action Date Heating Products Rulemakings Residential Water Heaters, Direct Heating Equipment, and Pool

311

Appliance Standards Update and Review of Certification, Compliance and Enforcement Powerpoint Presentation for ASHRAE Conference, January 31, 2011  

Broader source: Energy.gov (indexed) [DOE]

Buildings Regulatory Program Buildings Regulatory Program Buildings Regulatory Program Appliance Standards Update and Review of Certification, Compliance and Enforcement John Cymbalsky, Ashley Armstrong, and Laura Barhydt US Department of Energy January 31, 2011 Presentation Outline Presentation Outline * Upcoming Relevant Rulemakings * Changes to Rulemaking Process * Executive Order 13563 * Overview of Compliance, Certification, and Enforcement * Detailed Questions and Answers 2 | U.S. Department of Energy energy.gov Long Term Schedules for Certain HVAC Rulemakings Long Term Schedules for Certain HVAC Rulemakings Appliance Standards Product Categories Driver Approx. Rule Initiation Date Final Action Date Heating Products Rulemakings Residential Water Heaters, Direct Heating Equipment, and Pool

312

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Alternative Efficiency Determination Methods and Alternate Rating Methods Alternative Efficiency Determination Methods and Alternate Rating Methods Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is proposing to revise and expand its existing regulations governing the use of alternative efficiency determination methods (AEDM) and alternate rating methods (ARM) for covered products as alternatives to testing for the purpose of certifying compliance. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a final rule revising its existing regulations governing the use of particular methods as alternatives to testing for commercial heating, ventilating, air conditioning, water heating, and refrigeration equipment. 78 FR 79579 (December 31, 2013).

313

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Kitchen Ranges and Ovens Kitchen Ranges and Ovens Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy's (DOE) energy conservation standards for residential kitchen ranges and ovens since 1990. Residential kitchen ranges and ovens include conventional ranges, conventional cooking tops, conventional ovens, microwave ovens, and microwave/conventional ranges, known collectively as cooking products. Cooking products cook or heat food by means of gas, electricity, or microwave energy. These products are used primarily in homes and apartments. Kitchen ranges and ovens do not include portable or countertop ovens that use electric resistance heating or are designed to use an electrical supply of approximately 120 volts. For information about microwave ovens, go to microwave ovens.

314

High Temperature Water Heat Pipes Radiator for a Brayton Space Reactor Power System  

SciTech Connect (OSTI)

A high temperature water heat pipes radiator design is developed for a space power system with a sectored gas-cooled reactor and three Closed Brayton Cycle (CBC) engines, for avoidance of single point failures in reactor cooling and energy conversion and rejection. The CBC engines operate at turbine inlet and exit temperatures of 1144 K and 952 K. They have a net efficiency of 19.4% and each provides 30.5 kWe of net electrical power to the load. A He-Xe gas mixture serves as the turbine working fluid and cools the reactor core, entering at 904 K and exiting at 1149 K. Each CBC loop is coupled to a reactor sector, which is neutronically and thermally coupled, but hydraulically decoupled to the other two sectors, and to a NaK-78 secondary loop with two water heat pipes radiator panels. The segmented panels each consist of a forward fixed segment and two rear deployable segments, operating hydraulically in parallel. The deployed radiator has an effective surface area of 203 m2, and when the rear segments are folded, the stowed power system fits in the launch bay of the DELTA-IV Heavy launch vehicle. For enhanced reliability, the water heat pipes operate below 50% of their wicking limit; the sonic limit is not a concern because of the water, high vapor pressure at the temperatures of interest (384 - 491 K). The rejected power by the radiator peaks when the ratio of the lengths of evaporator sections of the longest and shortest heat pipes is the same as that of the major and minor widths of the segments. The shortest and hottest heat pipes in the rear segments operate at 491 K and 2.24 MPa, and each rejects 154 W. The longest heat pipes operate cooler (427 K and 0.52 MPa) and because they are 69% longer, reject more power (200 W each). The longest and hottest heat pipes in the forward segments reject the largest power (320 W each) while operating at {approx} 46% of capillary limit. The vapor temperature and pressure in these heat pipes are 485 K and 1.97 MPa. By contrast, the shortest water heat pipes in the forward segments operate much cooler (427 K and 0.52 MPa), and reject a much lower power of 45 W each. The radiator with six fixed and 12 rear deployable segments rejects a total of 324 kWth, weights 994 kg and has an average specific power of 326 Wth/kg and a specific mass of 5.88 kg/m2.

El-Genk, Mohamed S.; Tournier, Jean-Michel [Institute for Space and Nuclear Power Studies, University of New Mexico, Albuquerque, NM 87131 (United States); Chemical and Nuclear Engineering Department, University of New Mexico, Albuquerque, NM 87131 (United States)

2006-01-20T23:59:59.000Z

315

Smart Domestic Appliances Provide Flexibility for Sustainable Energy  

Open Energy Info (EERE)

Smart Domestic Appliances Provide Flexibility for Sustainable Energy Smart Domestic Appliances Provide Flexibility for Sustainable Energy Systems (Webinar) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Smart Domestic Appliances Provide Flexibility for Sustainable Energy Systems (Webinar) Focus Area: Crosscutting Topics: Training Material Website: www.leonardo-energy.org/webinar-smart-domestic-appliances-provide-flex Equivalent URI: cleanenergysolutions.org/content/smart-domestic-appliances-provide-fle Language: English Policies: "Deployment Programs,Regulations" is not in the list of possible values (Deployment Programs, Financial Incentives, Regulations) for this property. DeploymentPrograms: Demonstration & Implementation Regulations: Net Metering & Interconnection In this video, the viewer learns about the benefits and difficulties

316

Status of not-in-kind refrigeration technologies for household space conditioning, water heating and food refrigeration  

SciTech Connect (OSTI)

This paper presents a review of the next generation not-in-kind technologies to replace conventional vapor compression refrigeration technology for household applications. Such technologies are sought to provide energy savings or other environmental benefits for space conditioning, water heating and refrigeration for domestic use. These alternative technologies include: thermoacoustic refrigeration, thermoelectric refrigeration, thermotunneling, magnetic refrigeration, Stirling cycle refrigeration, pulse tube refrigeration, Malone cycle refrigeration, absorption refrigeration, adsorption refrigeration, and compressor driven metal hydride heat pumps. Furthermore, heat pump water heating and integrated heat pump systems are also discussed due to their significant energy saving potential for water heating and space conditioning in households. The paper provides a snapshot of the future R&D needs for each of the technologies along with the associated barriers. Both thermoelectric and magnetic technologies look relatively attractive due to recent developments in the materials and prototypes being manufactured.

Bansal, Pradeep [ORNL; Vineyard, Edward Allan [ORNL; Abdelaziz, Omar [ORNL

2012-01-01T23:59:59.000Z

317

Application Analysis of Ground Source Heat Pumps in Building Space Conditioning  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Application Analysis of Ground Source Heat Application Analysis of Ground Source Heat Pumps in Building Space Conditioning Hua Qian 1,2 , Yungang Wang 2 1 School of Energy and Environment Southeast University Nanjing, 210096, China 2 Environmental Energy Technologies Division Lawrence Berkeley National Laboratory Berkeley, CA 94720, USA July 2013 The project was supported by National Key Technology Supported Program of China (2011BAJ03B10-1) and by the U.S. Department of Energy under Contract No. DE-AC02- 05CH11231. Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the

318

Impact of Ducting on Heat Pump Water Heater Space Conditioning Energy Use and Comfort  

SciTech Connect (OSTI)

Increasing penetration of heat pump water heaters (HPWHs) in the residential sector will offer an important opportunity for energy savings, with a theoretical energy savings of up to 63% per water heater and up to 11% of residential energy use (EIA 2009). However, significant barriers must be overcome before this technology will reach widespread adoption in the Pacific Northwest region and nationwide. One significant barrier noted by the Northwest Energy Efficiency Alliance (NEEA) is the possible interaction with the homes space conditioning system for units installed in conditioned spaces. Such complex interactions may decrease the magnitude of whole-house savings available from HPWH installed in the conditioned space in cold climates and could lead to comfort concerns (Larson et al. 2011; Kresta 2012). Modeling studies indicate that the installation location of HPWHs can significantly impact their performance and the resultant whole-house energy savings (Larson et al. 2012; Maguire et al. 2013). However, field data are not currently available to validate these results. This field evaluation of two GE GeoSpring HPWHs in the PNNL Lab Homes is designed to measure the performance and impact on the Lab Home HVAC system of a GE GeoSpring HPWH configured with exhaust ducting compared to an unducted GeoSpring HPWH during heating and cooling season periods; and measure the performance and impact on the Lab Home HVAC system of the GeoSpring HPWH with both supply and exhaust air ducting as compared to an unducted GeoSpring HPWH during heating and cooling season periods. Important metrics evaluated in these experiments include water heater energy use, HVAC energy use, whole house energy use, interior temperatures (as a proxy for thermal comfort), and cost impacts. This technical report presents results from the PNNL Lab Homes experiment.

Widder, Sarah H.; Petersen, Joseph M.; Parker, Graham B.; Baechler, Michael C.

2014-07-21T23:59:59.000Z

319

U-197: Cisco Adaptive Security Appliances Denial of Service Vulnerability |  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

97: Cisco Adaptive Security Appliances Denial of Service 97: Cisco Adaptive Security Appliances Denial of Service Vulnerability U-197: Cisco Adaptive Security Appliances Denial of Service Vulnerability June 22, 2012 - 7:00am Addthis PROBLEM: A vulnerability has been reported in Cisco Adaptive Security Appliances (ASA), which can be exploited by malicious people to cause a DoS (Denial of Service). PLATFORM: Cisco Adaptive Security Appliance (ASA) 8.x Cisco ASA 5500 Series Adaptive Security Appliances ABSTRACT: The vulnerability is caused due to an unspecified error when handling IPv6 transit traffic and can be exploited to cause a reload of the affected device. reference LINKS: Vendor Advisory Secunia ID 49647 CVE-2012-3058 IMPACT ASSESSMENT: High Discussion: Cisco ASA 5500 Series Adaptive Security Appliances (Cisco ASA) and Cisco

320

Appliance Rebates: Frequently Asked Questions | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Appliance Rebates: Frequently Asked Questions Appliance Rebates: Frequently Asked Questions Appliance Rebates: Frequently Asked Questions April 26, 2010 - 4:55pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory The appliance rebate program has been wildly successful in many states. So successful, in fact, that people have plenty of questions and aren't always finding the answers they need. Whether you're just learning about the appliance rebate program or have some nagging questions, I hope this information is helpful to you. For the most up-to-date information on rebates in your state, click on your state on Approved Energy Efficient Appliance Rebate Programs. Below is a list of the most common questions, taken from the Energy Savers Appliance Rebates page. (Note: The FAQs below are current as of this

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Estimating Appliance and Home Electronic Energy Use | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Estimating Appliance and Home Electronic Energy Use Estimating Appliance and Home Electronic Energy Use Estimating Appliance and Home Electronic Energy Use November 11, 2013 - 4:23pm Addthis Estimate the energy consumption and cost to operate an appliance when making a purchase. Investing in an energy-efficient product may save you money in the long run. | Photo courtesy of iStockphoto.com/wh1600. Estimate the energy consumption and cost to operate an appliance when making a purchase. Investing in an energy-efficient product may save you money in the long run. | Photo courtesy of iStockphoto.com/wh1600. If you're trying to decide whether to invest in a more energy-efficient appliance or you'd like to determine your electricity loads, you may want to estimate appliance energy consumption. Formula for Estimating Energy Consumption

322

Wyoming's Appliance Rebate Program Surges Ahead | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Wyoming's Appliance Rebate Program Surges Ahead Wyoming's Appliance Rebate Program Surges Ahead Wyoming's Appliance Rebate Program Surges Ahead October 19, 2010 - 12:43pm Addthis Wyoming residents can receive rebates on ENERGY STAR appliances such as clothes washers. | File photo Wyoming residents can receive rebates on ENERGY STAR appliances such as clothes washers. | File photo Lindsay Gsell What does this mean for me? Wyoming received $511,000 in Recovery Act funding for its appliance rebate program. The program has already distributed 60% of rebate funding. Wyoming's appliance rebate program, which opened in April, continues through this fall. Residents of the Equality State can receive rebates on ENERGY STAR certified clothes washers, dishwashers, water heaters and gas furnaces ranging from $50 to $250.

323

Estimating Appliance and Home Electronic Energy Use | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Appliance and Home Electronic Energy Use Appliance and Home Electronic Energy Use Estimating Appliance and Home Electronic Energy Use November 11, 2013 - 4:23pm Addthis Estimate the energy consumption and cost to operate an appliance when making a purchase. Investing in an energy-efficient product may save you money in the long run. | Photo courtesy of iStockphoto.com/wh1600. Estimate the energy consumption and cost to operate an appliance when making a purchase. Investing in an energy-efficient product may save you money in the long run. | Photo courtesy of iStockphoto.com/wh1600. If you're trying to decide whether to invest in a more energy-efficient appliance or you'd like to determine your electricity loads, you may want to estimate appliance energy consumption. Formula for Estimating Energy Consumption

324

Appliance Standards and Rulemaking Federal Advisory Committee | Department  

Broader source: Energy.gov (indexed) [DOE]

Appliance & Equipment Standards » Rulemakings & Notices » Appliance & Equipment Standards » Rulemakings & Notices » Appliance Standards and Rulemaking Federal Advisory Committee Appliance Standards and Rulemaking Federal Advisory Committee The Appliance and Equipment Standards Program established the Appliance Standards and Rulemaking Federal Advisory Committee (ASRAC) in an effort to further improve the Department of Energy's (DOE) process of establishing energy efficiency standards for certain appliances and commercial equipment. ASRAC will allow DOE to use negotiated rulemaking as a means to engage all interested parties, gather data, and attempt to reach consensus on establishing energy efficiency standards. Rules drafted by negotiation may be more pragmatic and implemented at earlier dates than under a more

325

Appliance Rebates: Frequently Asked Questions | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Appliance Rebates: Frequently Asked Questions Appliance Rebates: Frequently Asked Questions Appliance Rebates: Frequently Asked Questions April 26, 2010 - 4:55pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory The appliance rebate program has been wildly successful in many states. So successful, in fact, that people have plenty of questions and aren't always finding the answers they need. Whether you're just learning about the appliance rebate program or have some nagging questions, I hope this information is helpful to you. For the most up-to-date information on rebates in your state, click on your state on Approved Energy Efficient Appliance Rebate Programs. Below is a list of the most common questions, taken from the Energy Savers Appliance Rebates page. (Note: The FAQs below are current as of this

326

Cixi Renhe Photovoltaic Electrical Appliance Co Ltd | Open Energy  

Open Energy Info (EERE)

Cixi Renhe Photovoltaic Electrical Appliance Co Ltd Cixi Renhe Photovoltaic Electrical Appliance Co Ltd Jump to: navigation, search Name Cixi Renhe Photovoltaic Electrical Appliance Co Ltd Place Cixi, Zhejiang Province, China Zip 315322 Sector Solar Product Zhejiang-based product manufacturer for solar modules. References Cixi Renhe Photovoltaic Electrical Appliance Co Ltd[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Cixi Renhe Photovoltaic Electrical Appliance Co Ltd is a company located in Cixi, Zhejiang Province, China . References ↑ "Cixi Renhe Photovoltaic Electrical Appliance Co Ltd" Retrieved from "http://en.openei.org/w/index.php?title=Cixi_Renhe_Photovoltaic_Electrical_Appliance_Co_Ltd&oldid=343628

327

Appliance and Equipment Efficiency Standards | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Appliance and Equipment Efficiency Standards Appliance and Equipment Efficiency Standards Appliance and Equipment Efficiency Standards < Back Savings Category Appliances & Electronics Commercial Lighting Lighting Program Info State Rhode Island Program Type Appliance/Equipment Efficiency Standards Provider Rhode Island Office of Energy Resources '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will

328

Estimating Appliance and Home Electronic Energy Use | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Estimating Appliance and Home Electronic Energy Use Estimating Appliance and Home Electronic Energy Use Estimating Appliance and Home Electronic Energy Use November 11, 2013 - 4:23pm Addthis Estimate the energy consumption and cost to operate an appliance when making a purchase. Investing in an energy-efficient product may save you money in the long run. | Photo courtesy of iStockphoto.com/wh1600. Estimate the energy consumption and cost to operate an appliance when making a purchase. Investing in an energy-efficient product may save you money in the long run. | Photo courtesy of iStockphoto.com/wh1600. If you're trying to decide whether to invest in a more energy-efficient appliance or you'd like to determine your electricity loads, you may want to estimate appliance energy consumption. Formula for Estimating Energy Consumption

329

Energy Efficient Appliance Sales Soar in North Carolina | Department of  

Broader source: Energy.gov (indexed) [DOE]

Energy Efficient Appliance Sales Soar in North Carolina Energy Efficient Appliance Sales Soar in North Carolina Energy Efficient Appliance Sales Soar in North Carolina July 23, 2010 - 11:00am Addthis Joshua DeLung What does this mean for me? The program discounted 62,970 appliances. $8.8 million in Recovery Act funding spurred $64 million in retail sales. A total of $300 million in Recovery Act funding was allotted nationwide for appliance rebates. It took just eight days total for North Carolina retailers to rack up $64 million in sales of appliances under the $8.9 million American Recovery and Reinvestment Act investment through the state's Appliance Rebate Program. "In very real ways, this has stimulated our economy and moved money in North Carolina," said Seth Effron, communications director for the North

330

Wyoming's Appliance Rebate Program Surges Ahead | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Wyoming's Appliance Rebate Program Surges Ahead Wyoming's Appliance Rebate Program Surges Ahead Wyoming's Appliance Rebate Program Surges Ahead October 19, 2010 - 12:43pm Addthis Wyoming residents can receive rebates on ENERGY STAR appliances such as clothes washers. | File photo Wyoming residents can receive rebates on ENERGY STAR appliances such as clothes washers. | File photo Lindsay Gsell What does this mean for me? Wyoming received $511,000 in Recovery Act funding for its appliance rebate program. The program has already distributed 60% of rebate funding. Wyoming's appliance rebate program, which opened in April, continues through this fall. Residents of the Equality State can receive rebates on ENERGY STAR certified clothes washers, dishwashers, water heaters and gas furnaces ranging from $50 to $250.

331

Solergie Qingdao Electrical Appliance Co Ltd | Open Energy Information  

Open Energy Info (EERE)

Solergie Qingdao Electrical Appliance Co Ltd Solergie Qingdao Electrical Appliance Co Ltd Jump to: navigation, search Name Solergie (Qingdao)Electrical Appliance Co Ltd Place Qingdao, Shandong Province, China Zip 266701 Sector Solar Product A wholly foreign-owned enterprise. which is specialized in developing and manufacturing solar lighting and other energy solar products. References Solergie (Qingdao)Electrical Appliance Co Ltd[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Solergie (Qingdao)Electrical Appliance Co Ltd is a company located in Qingdao, Shandong Province, China . References ↑ "Solergie (Qingdao)Electrical Appliance Co Ltd" Retrieved from "http://en.openei.org/w/index.php?title=Solergie_Qingdao_Electrical_Appliance_Co_Ltd&oldid=351468

332

General-purpose heat source project and space nuclear safety fuels program. Progress report, February 1980  

SciTech Connect (OSTI)

This formal monthly report covers the studies related to the use of /sup 238/PuO/sub 2/ in radioisotopic power systems carried out for the Advanced Nuclear Systems and Projects Division of the Los Alamos Scientific Laboratory. The two programs involved are: General-Purpose Heat Source Development and Space Nuclear Safety and Fuels. Most of the studies discussed here are of a continuing nature. Results and conclusions described may change as the work continues. Published reference to the results cited in this report should not be made without the explicit permission of the person in charge of the work.

Maraman, W.J. (comp.)

1980-05-01T23:59:59.000Z

333

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Furnace Fans Furnace Fans Sign up for e-mail updates on regulations for this and other products Currently there are no energy conservation standards for residential furnace fans. A furnace fan is an electrically-powered device used in residential central heating, ventilation, and air conditioning (HVAC) systems for the purposes of circulating air through duct work. A furnace fan consists of a fan motor and its controls, a centrifugal impeller, and sheet metal housing. The Department of Energy (DOE) is currently conducting an energy conservation standard rulemaking for furnace fans. If any standard is established, its benefits will be explained in the final rule. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information

334

Development of a coal fired pulse combustor for residential space heating. Phase I, Final report  

SciTech Connect (OSTI)

This report presents the results of the first phase of a program for the development of a coal-fired residential combustion system. This phase consisted of the design, fabrication, testing, and evaluation of an advanced pulse combustor sized for residential space heating requirements. The objective was to develop an advanced pulse coal combustor at the {approximately} 100,000 Btu/hr scale that can be integrated into a packaged space heating system for small residential applications. The strategy for the development effort included the scale down of the feasibility unit from 1-2 MMBtu/hr to 100,000 Btu/hr to establish a baseline for isolating the effect of scale-down and new chamber configurations separately. Initial focus at the residential scale was concentrated on methods of fuel injection and atomization in a bare metal unit. This was followed by incorporating changes to the advanced chamber designs and testing of refractory-lined units. Multi-fuel capability for firing oil or gas as a secondary fuel was also established. Upon completion of the configuration and component testing, an optimum configuration would be selected for integrated testing of the pulse combustor unit. The strategy also defined the use of Dry Ultrafine Coal (DUC) for Phases 1 and 2 of the development program with CWM firing to be a product improvement activity for a later phase of the program.

NONE

1988-04-01T23:59:59.000Z

335

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Walk-in Coolers and Walk-in Freezers Energy Conservation Standards Walk-in Coolers and Walk-in Freezers Energy Conservation Standards Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is conducting a rulemaking to establish performance-based standards for walk-in coolers and walk-in freezers (WICF). WICFs temporarily store refrigerated or frozen food or other perishable goods and are used primarily in the food service and food sales industry. Walk-in coolers operate above 32°F and at or below 55°F, and walk-in freezers operate at or below 32°F. WICFs covered by the regulations are enclosed storage spaces that can be walked into, have a total chilled storage area of less than 3,000 square feet, and do not include products designed and marketed exclusively for medical, scientific, or research purposes.

336

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

High-Intensity Discharge Lamps High-Intensity Discharge Lamps Sign up for e-mail updates on regulations for this and other products There are currently no energy conservation standards for high-intensity discharge (HID) lamps. HID lamps are electric discharge lamps and include high-pressure sodium, mercury vapor, and metal halide lamps. HID lamps require an HID ballast to start and regulate electric current flow through the lamp. HID lamps are used in street and roadway lighting, area lighting such as for parking lots and plazas, industrial and commercial building interior lighting, security lighting for commercial, industrial, and residential spaces, and landscape lighting. The Standards and Test Procedures for this product are related to Rulemaking for High Intensity Discharge Lamps Energy Conservation Standard and Rulemaking for High Intensity Discharge Lamps Test Procedures.

337

Appliance Efficiency Standards and Price Discrimination  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Appliance Efficiency Standards and Price Discrimination Appliance Efficiency Standards and Price Discrimination Title Appliance Efficiency Standards and Price Discrimination Publication Type Report LBNL Report Number LBNL-6283E Year of Publication 2013 Authors Spurlock, Anna C. Date Published 05/2013 Keywords EES-EG Abstract I explore the effects of two simultaneous changes in minimum energy efficiency and ENERGY STAR standards for clothes washers. Adapting the Mussa and Rosen (1978) and Ronnen (1991) second-degree price discrimination model, I demonstrate that clothes washer prices and menus adjusted to the new standards in patterns consistent with a market in which firms had been price discriminating. In particular, I show evidence of discontinuous price drops at the time the standards were imposed, driven largely by mid-low efficiency segments of the market. The price discrimination model predicts this result. On the other hand, in a perfectly competition market, prices should increase for these market segments. Additionally, new models proliferated in the highest efficiency market segment following the standard changes. Finally, I show that firms appeared to use different adaptation strategies at the two instances of the standards

338

Space Heating Scenarios for Ontario: a Demonstration of the Statistics Canada Household Model  

Science Journals Connector (OSTI)

ABSTRACT This paper describes the analytical and simulation capabilities of the currently implemented version of the household model developed by the Structural Analysis Division, Statistics Canada. The household model, as described in A Design Framework for Long Term Energy Economic Analysis of Dwelling Related Demand [1], is a simulation framework and related data base of the Canadian housing stocks, residential construction, and end-use energy consumption in the residential sector. The purpose of the model is to provide an analytical tool for evaluating a variety of residential energy conservation strategies including insulation retrofitting and the introduction of new building standards, the possibilities for fuel substitution afforded by equipment retrofitting, and the impact of new technologies for space conditioning with respect to impacts on residential energy requirements and construction materials over time. The simulation results for Ontario that are presented in the paper are for demonstration purposes only and do not constitute a forecast. The choice of Ontario was arbitrary; similar calculations can be performed for other provinces, for Canada as a whole, and for selected subprovincial regions. At the time of preparation of this paper, the population and household formation block at the national level, the housing stock block, and the space heating part of the space conditioning block are implemented. Therefore simulation results are limited to these areas.

R.H.H. Moll; K.H. Dickinson

1982-01-01T23:59:59.000Z

339

Appliance and Equipment Energy Efficiency Standards | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Appliance and Equipment Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards < Back Program Info State Oregon Program Type Appliance/Equipment Efficiency Standards Provider Oregon Department of Energy '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for

340

Presenting a New (and Cool) Appliance Efficiency Standard | Department of  

Broader source: Energy.gov (indexed) [DOE]

Presenting a New (and Cool) Appliance Efficiency Standard Presenting a New (and Cool) Appliance Efficiency Standard Presenting a New (and Cool) Appliance Efficiency Standard September 29, 2010 - 5:24pm Addthis Elizabeth Meckes Elizabeth Meckes Director of User Experience & Digital Technologies, Office of Public Affairs What does this mean for me? The proposed appliance standard could save consumers as much as $18.6 billion over thirty years Proposed standards could save nearly 4.5 quadrillion BTUs over 30 years Secretary Chu recently announced a proposed new energy efficiency standard that could help save energy, money and your food - a proposed appliance standard for residential refrigerators, refrigerator-freezers and freezers that could save consumers as much as $18.6 billion over thirty years. Along with appliance efficiency standards, refrigerators have advanced a

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Fort Collins Utilities - Residential and Small Commercial Appliance Rebate  

Broader source: Energy.gov (indexed) [DOE]

and Small Commercial Appliance and Small Commercial Appliance Rebate Program Fort Collins Utilities - Residential and Small Commercial Appliance Rebate Program < Back Eligibility Residential Savings Category Appliances & Electronics Program Info Funding Source Fort Collins Utilities and the Governor's Energy Office State Colorado Program Type Utility Rebate Program Rebate Amount Clothes washer: $50 Dishwasher: $25 Refrigerator/Freezer Recycling: $35, plus free pick-up Fort Collins Utilities offers a number of appliance and recycling rebates to residential and small commercial customers. The appliance rebate program offers a $50 rebate for Energy Star rated clothes washers and $25 for Energy Star dishwashers. Applications for equipment rebates are available on the Fort Collins web site as well as at select local manufacturers and

342

Energy Efficiency Standards for Appliances | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Efficiency Standards for Appliances Efficiency Standards for Appliances Energy Efficiency Standards for Appliances < Back Program Info State Connecticut Program Type Appliance/Equipment Efficiency Standards Provider Department of Energy and Environmental Protection '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for

343

Land of Enchantment's Appliance Rebate Program Spurs Shopping | Department  

Broader source: Energy.gov (indexed) [DOE]

Land of Enchantment's Appliance Rebate Program Spurs Shopping Land of Enchantment's Appliance Rebate Program Spurs Shopping Land of Enchantment's Appliance Rebate Program Spurs Shopping September 20, 2010 - 10:00am Addthis Lindsay Gsell What does this project do? Issued 8830 appliance rebates in Arizona. One local business saw an 80% sales increase weeks after the launch of the appliance rebate program. Rebates can add up quickly - especially when 8,830 are issued. Through Recovery Act funding, New Mexico has distributed about 8,830 rebates worth $200 for ENERGY STAR qualified refrigerators, clothes washers and gas furnaces. The state's appliance rebate program launched on April 22 -- Earth Day -- and is currently winding down, with a little more than $125,000 available for furnace rebates. Program manager Harold Trujillo says that more than half the rebates were

344

Streamlining ENERGY STAR Appliance Testing | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Streamlining ENERGY STAR Appliance Testing Streamlining ENERGY STAR Appliance Testing Streamlining ENERGY STAR Appliance Testing September 26, 2013 - 11:46am Addthis To save taxpayer dollars and help lower the costs of innovative energy-efficient technologies, the Energy Department is streamlining ENERGY STAR testing for appliances such as clothes washers. | Photo courtesy of Bethany Sparn, National Renewable Energy Laboratory. To save taxpayer dollars and help lower the costs of innovative energy-efficient technologies, the Energy Department is streamlining ENERGY STAR testing for appliances such as clothes washers. | Photo courtesy of Bethany Sparn, National Renewable Energy Laboratory. John Cymbalsky Program Manager, Appliance and Equipment Standards & Building Codes What does this mean for me?

345

Rebates for ENERGY STAR Appliances: State Stories | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Rebates for ENERGY STAR Appliances: State Stories Rebates for ENERGY STAR Appliances: State Stories Rebates for ENERGY STAR Appliances: State Stories July 19, 2010 - 7:30am Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory As you're probably aware by now, every state and U.S. territory has been given funds from the American Recovery and Reinvestment Act of 2009 to allow eligible consumers to receive rebates for the purchase of new energy-efficient appliances when they replace used appliances. So, how's the program working? The answer is: great overall. The response has been enormous (as many of you have probably witnessed) as people have purchased an unprecedented number of clothes washers, refrigerators, and other home appliances. Here's an example of the program's impact in Florida:

346

West Virginia Consumers Have Appliance Rebate 'Trifecta' | Department of  

Broader source: Energy.gov (indexed) [DOE]

Consumers Have Appliance Rebate 'Trifecta' Consumers Have Appliance Rebate 'Trifecta' West Virginia Consumers Have Appliance Rebate 'Trifecta' September 13, 2010 - 10:30am Addthis West Virginia Governor Joe Manchin announces the Energy Efficient Rebate Program in June. The state received $1.7 million in Recovery Act funding to encourage residents to purchase ENERGY STAR appliances. | Photo courtesy of WVDEP West Virginia Governor Joe Manchin announces the Energy Efficient Rebate Program in June. The state received $1.7 million in Recovery Act funding to encourage residents to purchase ENERGY STAR appliances. | Photo courtesy of WVDEP Stephen Graff Former Writer & editor for Energy Empowers, EERE What are the key facts? West Virginia residents receive up to $100 in rebates for ENERGY STAR appliances

347

Streamlining ENERGY STAR Appliance Testing | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Streamlining ENERGY STAR Appliance Testing Streamlining ENERGY STAR Appliance Testing Streamlining ENERGY STAR Appliance Testing September 26, 2013 - 11:46am Addthis To save taxpayer dollars and help lower the costs of innovative energy-efficient technologies, the Energy Department is streamlining ENERGY STAR testing for appliances such as clothes washers. | Photo courtesy of Bethany Sparn, National Renewable Energy Laboratory. To save taxpayer dollars and help lower the costs of innovative energy-efficient technologies, the Energy Department is streamlining ENERGY STAR testing for appliances such as clothes washers. | Photo courtesy of Bethany Sparn, National Renewable Energy Laboratory. John Cymbalsky Program Manager, Appliance and Equipment Standards & Building Codes What does this mean for me?

348

Appliance Standby Power and Energy Consumption in South African Households  

Open Energy Info (EERE)

Appliance Standby Power and Energy Consumption in South African Households Appliance Standby Power and Energy Consumption in South African Households Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Appliance Standby Power and Energy Consumption in South African Households Focus Area: Appliances & Equipment Topics: Policy Impacts Website: active.cput.ac.za/energy/web/DUE/DOCS/422/Paper%20-%20Shuma-Iwisi%20M. Equivalent URI: cleanenergysolutions.org/content/appliance-standby-power-and-energy-co Language: English Policies: Deployment Programs DeploymentPrograms: Technical Assistance A modified engineering model is proposed to estimate standby power and energy losses in households. The modified model accounts for the randomness of standby power and energy losses due to unpredicted user appliance operational behavior.

349

Appliance and Equipment Energy Efficiency Standards | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Appliance and Equipment Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards < Back Program Info State District of Columbia Program Type Appliance/Equipment Efficiency Standards Provider Washington State Department of Commerce '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for

350

Energy Efficiency Standards for Appliances | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Energy Efficiency Standards for Appliances Energy Efficiency Standards for Appliances Energy Efficiency Standards for Appliances < Back Program Info State District of Columbia Program Type Appliance/Equipment Efficiency Standards Provider District Department of the Environment '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for

351

Hydrophilic structures for condensation management in refrigerator appliances  

DOE Patents [OSTI]

A refrigerator appliance that includes a freezer compartment having a freezer compartment door, and a refrigeration compartment having at least one refrigeration compartment door. The appliance further includes a mullion with an exterior surface. The mullion divides the compartments and the exterior surface directs condensation toward a transfer point. The appliance may also include a cabinet that houses the compartments and has two sides, each with an exterior surface. Further, at least one exterior surface directs condensation toward a transfer point.

Kuehl, Steven John; Vonderhaar, John J; Wu, Guolian; Wu, Mianxue

2014-10-21T23:59:59.000Z

352

International Cooperation on Advancing Equipment and Appliance Efficiency  

Broader source: Energy.gov (indexed) [DOE]

Equipment and Equipment and Appliance Efficiency The Superefficient Equipment and Appliance Deployment (SEAD) Initiative 1 What is SEAD? * SEAD is a global market transformation initiative for deploying super-efficient equipment and appliances. * SEAD has three goals: - To raise the efficiency ceiling * Pull super-efficient appliances and equipment into the market through cooperation on measures like incentives, procurement, awards, and R&D investments - To raise the efficiency floor * Work together to bolster national or regional policies like minimum efficiency standards - To strengthen the foundations of efficiency programs * Coordinate technical work to support these activities 2 SEAD Partners Australia European Commission Canada France Germany India Japan Korea Mexico

353

2014-08-19 Issuance Appliance Standards and Rulemaking Federal...  

Energy Savers [EERE]

2014-08-19 Issuance Appliance Standards and Rulemaking Federal Advisory Committee (ASRAC) - Central Air Conditioner Regional Standards Enforcement Working Group; Notice of Open...

354

Orange and Rockland Utilities (Electric)- Residential Appliance Recycling Program  

Broader source: Energy.gov [DOE]

Orange and Rockland Utilities provides rebates for residential customers for recycling older, inefficient refrigerators and freezers. All appliances must meet the program requirements listed on the...

355

Kitchen Appliance Upgrades Improve Water Efficiency at DOD Exchange...  

Broader source: Energy.gov (indexed) [DOE]

Kitchen Appliance Upgrades Improve Water Efficiency at DOD Exchange Facilities: Best Management Practice Case Study 11: Commercial Kitchen Equipment (Brochure), Federal Energy...

356

Low-cost Appliance State Sensing for Energy Disaggregation.  

E-Print Network [OSTI]

??Fine-grained per appliance electrical energy consumption data is crucial to electrical energy conservation. However, energy meters are installed at few central points in buildings, providing (more)

Wu, Tianji

2012-01-01T23:59:59.000Z

357

Expert Meeting Report: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems  

Broader source: Energy.gov (indexed) [DOE]

Recommendations for Applying Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems A. Rudd, K. Ueno, D. Bergey, R. Osser Building Science Corporation June 2012 i This report received minimal editorial review at NREL. NOTICE This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, subcontractors, or affiliated partners makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark,

358

Solar space- and water-heating system at Stanford University. Final report  

SciTech Connect (OSTI)

Application of an active hydronic domestic hot water and space heating solar system for the Central Food Services Building is discussed. The closed-loop drain-back system is described as offering dependability of gravity drain-back freeze protection, low maintenance, minimal costs, and simplicity. The system features an 840 square-foot collector and storage capacity of 1550 gallons. The acceptance testing and the predicted system performance data are briefly described. Solar performance calculations were performed using a computer design program (FCHART). Bidding, costs, and economics of the system are reviewed. Problems are discussed and solutions and recommendations given. An operation and maintenance manual is given in Appendix A, and Appendix B presents As-built Drawings. (MCW)

Not Available

1980-05-01T23:59:59.000Z

359

Optimization of solar assisted ground source heat pump system for space heating application by Taguchi method and utility concept  

Science Journals Connector (OSTI)

Abstract In the present research, a methodology is proposed to optimize the solar collector area and ground heat exchanger length for achieving higher COP of Solar Assisted Ground Source Heat Pump (SAGSHP) system using Taguchi method and utility concept. Four operating parameters for solar collector and four parameters for ground heat exchanger have been selected with mixed level variation using an L18 (21, 37) orthogonal array. The key parameters such as solar collector area, ground heat exchanger length and COP of the SAGSHP system are optimized to predict the best levels of operating parameters for maximum COP of SAGSHP system. Lower the better concept has been used for the solar collector area and ground heat exchanger length whereas higher the better concept has been employed for the COP of SAGSHP system and the results have been analyzed for the optimum conditions using signal-to-noise (SN) ratio and ANOVA method. Computations were carried out for 18 experimental trial runs by considering 2ton heating load in winter season. The optimum COP for SAGSHP was estimated to be 4.23 from the utility concept, which is 8.74% higher than the optimum COP predicted by Taguchi optimization. Optimization of solar collector area and ground heat exchanger length by the utility concept has shown only about 2.3% reduction in area and 1.6% reduction in length respectively compared to those values optimized by the Taguchi method.

Vikas Verma; K. Murugesan

2014-01-01T23:59:59.000Z

360

Geothermal energy development in the Eastern United States. Technical assistance report No. 4. Geothermal space heating: Pittsville Middle/Elementary School, Pittsville, Maryland  

SciTech Connect (OSTI)

A technical evaluation was made to determine whether geothermal energy obtained from a well could be used to space heat the new school building being constructed as well as the existing elementary wing of the Pittsville School. The first part deals with space heating the new school building only; the second part pertains to space heating the new school building together with the new existing wing. An addendum was added for new well and production pump costs. (MHR)

Briesen, R.V.; Yu, K.

1980-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Application analysis of ground source heat pumps in building space conditioning  

E-Print Network [OSTI]

temporal variation of the heat pump COP over the three-monthfor ground-source heat pumps. in ASHRAE Summer Meeting.savings of ground source heat pump systems in Europe: A

Qian, Hua

2014-01-01T23:59:59.000Z

362

Advances in Household Appliances- A Review  

SciTech Connect (OSTI)

An overview of options and potential barriers and risks for reducing the energy consumption, peak demand, and emissions for seven key energy consuming residential products (refrigerator-freezers, dishwashers, clothes washers, clothes dryers, electric ovens, gas ovens and microwave ovens) is presented. The paper primarily concentrates on the potential energy savings from the use of advanced technologies in appliances for the U.S. market. The significance and usefulness of each technology was evaluated in order to prioritize the R&D needs to improve energy efficiency of appliances in view of energy savings, cost, and complexity. The paper provides a snapshot of the future R&D needs for each of the technologies along with the associated barriers. Although significant energy savings may be achieved, one of the major barriers in most cases is high first cost. One way of addressing this issue and promoting the introduction of new technologies is to level the playing field for all manufacturers by establishing Minimum Energy Performance Standards (MEPS) which are not cost prohibitive and promoting energy efficient products through incentives to both manufacturers and consumers.

Bansal, Pradeep [ORNL; Vineyard, Edward Allan [ORNL; Abdelaziz, Omar [ORNL

2011-01-01T23:59:59.000Z

363

Development of Machine Vision Technology for Railcar Safety Appliance Inspection  

E-Print Network [OSTI]

American trains depart a terminal or rail yard, many aspects of the cars and locomotives undergo inspection the algorithm the differences between safety appliance defects that require immediate repair, and other types capable of inspecting safety appliance defects on passing railcars. Index Terms: Machine Vision, Railcar

Barkan, Christopher P.L.

364

Utility Rebates for ENERGY STAR Appliances: Are They Effective?  

E-Print Network [OSTI]

Utility Rebates for ENERGY STAR Appliances: Are They Effective? Souvik Datta Sumeet Gulati CEPE;UTILITY REBATES FOR ENERGY STAR APPLIANCES: ARE THEY EFFECTIVE? SOUVIK DATTA ETH Z¨urich SUMEET GULATI by utility companies. To estimate the impact of these incentives we use the variation in timing and size

365

International Comparison of Energy Efficiency Awards for Appliance Manufacturers and Retailers  

E-Print Network [OSTI]

Association of Home Appliance Manufacturers (AHAM),2012, AHAM Programs. http://www.aham.org/industry/ht/d/on market surveillance AHAM Association of Home Appliance

Zhou, Nan

2014-01-01T23:59:59.000Z

366

E-Print Network 3.0 - appliance ownership survey Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Roomba Is Rambo": Intimate Home Appliances Ja-Young Sung, Lan Guo, Rebecca E. Grinter... psychology literature which emphasizes 12;"My Roomba Is Rambo": Intimate Home Appliances...

367

GE Appliances: Proposed Penalty (2010-CE-2113) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

GE Appliances: Proposed Penalty (2010-CE-2113) GE Appliances: Proposed Penalty (2010-CE-2113) GE Appliances: Proposed Penalty (2010-CE-2113) September 8, 2010 DOE alleged in a Notice of Proposed Civil Penalty that General Electric Appliances failed to certify a variety of dehumidifiers as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. GE Appliances: Proposed Penalty (2010-CE-2113) More Documents & Publications De'Longhi USA: Proposed Penalty (2010-CE-2114)

368

Comparing Appliance and Lighting Energy Costs Online Just Got Easier |  

Broader source: Energy.gov (indexed) [DOE]

Comparing Appliance and Lighting Energy Costs Online Just Got Comparing Appliance and Lighting Energy Costs Online Just Got Easier Comparing Appliance and Lighting Energy Costs Online Just Got Easier January 11, 2013 - 10:12am Addthis The EnergyGuide and Lighting Facts labels help you understand both the purchase price and the operating cost when shopping for new appliances or lighting. The EnergyGuide and Lighting Facts labels help you understand both the purchase price and the operating cost when shopping for new appliances or lighting. What are the key facts? The FTC now requires online retailers to post the label for any product with an EnergyGuide or Lighting Facts label. In my house, we love to comparison shop. Before any major purchase, we spend a lot of time researching our options. We read reviews, compare

369

Definition: Smart Appliances And Equipment (Customer) | Open Energy  

Open Energy Info (EERE)

Appliances And Equipment (Customer) Appliances And Equipment (Customer) Jump to: navigation, search Dictionary.png Smart Appliances And Equipment (Customer) Home appliances and devices (i.e., thermostats, pool pumps, clothes washers/dryers, water heaters, etc.) that use wireless technology (i.e., ZigBee) to receive real-time data from the AMI system to control or modulate their operation.[1] Related Terms advanced metering infrastructure, smart grid References ↑ [www.smartgrid.gov/sites/default/files/pdfs/description_of_assets.pdf SmartGrid.gov 'Description of Assets'] An i LikeLike UnlikeLike You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Smart_Appliances_And_Equipment_(Customer)&oldid=493118"

370

Department Sets Aggressive Schedule for New Appliance Standards |  

Broader source: Energy.gov (indexed) [DOE]

Sets Aggressive Schedule for New Appliance Standards Sets Aggressive Schedule for New Appliance Standards Department Sets Aggressive Schedule for New Appliance Standards February 1, 2006 - 8:52am Addthis WASHINGTON, DC - The Department of Energy (DOE) today released a schedule for setting new appliance efficiency standards. The five-year plan outlines how DOE will work with all of its partners to address the appliance standards rulemaking backlog and meet all of the statutory requirements established in the Energy Policy and Conservation Act and the Energy Policy Act of 2005 (EPACT 2005). "Improved efficiency saves Americans money and energy," said Acting Assistant Secretary for Energy Efficiency and Renewable Energy, Douglas L. Faulkner. "This aggressive schedule shows our commitment to greater

371

Assessment of Literature Related to Combustion Appliance Venting Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Assessment of Literature Related to Combustion Appliance Venting Systems Assessment of Literature Related to Combustion Appliance Venting Systems Title Assessment of Literature Related to Combustion Appliance Venting Systems Publication Type Report LBNL Report Number LBNL-5798E Year of Publication 2012 Authors Rapp, Vi H., Brett C. Singer, J. Chris Stratton, and Craig P. Wray Date Published 06/2012 Abstract In many residential building retrofit programs, air tightening to increase energy efficiency is constrained by concerns about related impacts on the safety of naturally vented combustion appliances. Tighter housing units more readily depressurize when exhaust equipment is operated, making combustion appliances more prone to backdraft or spillage. Several test methods purportedly assess the potential for depressurization-induced backdrafting and spillage, but these tests are not robustly reliable and repeatable

372

State Energy Efficient Appliance Rebate Program is Closed | Department of  

Broader source: Energy.gov (indexed) [DOE]

State Energy Efficient Appliance Rebate Program is Closed State Energy Efficient Appliance Rebate Program is Closed State Energy Efficient Appliance Rebate Program is Closed February 23, 2012 - 5:22am Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory On Friday, February 17, 2012, the State Energy Efficient Appliance Rebate Program closed officially in all U.S. states and territories. Although the program had already closed in most states by this time, there were 11 states and territories that closed last Friday. The appliance rebate program has been a huge success across the country, and we've been getting results periodically. As of December 31, 2011, a total of 1.7 million consumer rebates, valued at $258 million, have been paid to consumers. The annual energy savings resulting from the purchase of

373

City of Lompoc Utilities - Residential Energy Efficient Appliance Rebate  

Broader source: Energy.gov (indexed) [DOE]

Residential Energy Efficient Appliance Residential Energy Efficient Appliance Rebate Program City of Lompoc Utilities - Residential Energy Efficient Appliance Rebate Program < Back Eligibility Low-Income Residential Residential Savings Category Appliances & Electronics Other Program Info State California Program Type Utility Rebate Program Rebate Amount Clothes Washer: $120 Dishwasher: $50 LED Holiday Lights: $4 - $8 Refrigerator Replacement Rebate: $144 Refrigerator Buy-Back Program: $35 Custom: $0.15/watt saved Provider Utility Conservation City of Lompoc Utilities (CLU) offers incentives to its residential customers for upgrading the energy efficiency of home appliances. CLU provides rebates paid monthly as credits on utility bills to customers who replace old clothes washers and dish washers with Energy Star labeled

374

Department Sets Aggressive Schedule for New Appliance Standards |  

Broader source: Energy.gov (indexed) [DOE]

Department Sets Aggressive Schedule for New Appliance Standards Department Sets Aggressive Schedule for New Appliance Standards Department Sets Aggressive Schedule for New Appliance Standards February 1, 2006 - 8:52am Addthis WASHINGTON, DC - The Department of Energy (DOE) today released a schedule for setting new appliance efficiency standards. The five-year plan outlines how DOE will work with all of its partners to address the appliance standards rulemaking backlog and meet all of the statutory requirements established in the Energy Policy and Conservation Act and the Energy Policy Act of 2005 (EPACT 2005). "Improved efficiency saves Americans money and energy," said Acting Assistant Secretary for Energy Efficiency and Renewable Energy, Douglas L. Faulkner. "This aggressive schedule shows our commitment to greater

375

Comparing Appliance and Lighting Energy Costs Online Just Got Easier |  

Broader source: Energy.gov (indexed) [DOE]

Appliance and Lighting Energy Costs Online Just Got Appliance and Lighting Energy Costs Online Just Got Easier Comparing Appliance and Lighting Energy Costs Online Just Got Easier January 11, 2013 - 10:12am Addthis The EnergyGuide and Lighting Facts labels help you understand both the purchase price and the operating cost when shopping for new appliances or lighting. The EnergyGuide and Lighting Facts labels help you understand both the purchase price and the operating cost when shopping for new appliances or lighting. What are the key facts? The FTC now requires online retailers to post the label for any product with an EnergyGuide or Lighting Facts label. In my house, we love to comparison shop. Before any major purchase, we spend a lot of time researching our options. We read reviews, compare specs, hunt for the best prices, and consider the long-term costs. The

376

Measured Performance and Analysis of Ground Source Heat Pumps for Space Conditioning and for Water Heating in a Low-Energy Test House Operated under Simulated Occupancy Conditions  

SciTech Connect (OSTI)

In this paper we present measured performance and efficiency metrics of Ground Source Heat Pumps (GSHPs) for space conditioning and for water heating connected to a horizontal ground heat exchanger (GHX) loop. The units were installed in a 345m2 (3700ft2) high-efficiency test house built with structural insulated panels (SIPs), operated under simulated occupancy conditions, and located in Oak Ridge, Tennessee (USA) in US Climate Zone 4 . The paper describes distinctive features of the building envelope, ground loop, and equipment, and provides detailed monthly performance of the GSHP system. Space conditioning needs of the house were completely satisfied by a nominal 2-ton (7.0 kW) water-to-air GSHP (WA-GSHP) unit with almost no auxiliary heat usage. Recommendations for further improvement through engineering design changes are identified. The comprehensive set of data and analyses demonstrate the feasibility and practicality of GSHPs in residential applications and their potential to help achieve source energy and greenhouse gas emission reduction targets set under the IECC 2012 Standard.

Ally, Moonis Raza [ORNL] [ORNL; Munk, Jeffrey D [ORNL] [ORNL; Baxter, Van D [ORNL] [ORNL; Gehl, Anthony C [ORNL] [ORNL

2012-01-01T23:59:59.000Z

377

Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings- Control strategies to improve hydronic space heating performance  

Broader source: Energy.gov [DOE]

This webinar was presented on July 16, 2014, and provided information about improving the performance of central space conditioning systems in multifamily buildings.

378

Modelling the impacts of building regulations and a property bubble on residential space and water heating  

Science Journals Connector (OSTI)

This paper develops a bottom-up model of space and water heating energy demand for new build dwellings in the Irish residential sector. This is used to assess the impacts of measures proposed in Ireland's National Energy Efficiency Action Plan (NEEAP). The impact of the housing construction boom, which resulted in 23% of occupied dwellings in 2008 having been built since 2002, and the subsequent bust, are also assessed. The model structure treats separately new dwellings added to the stock after 2007 and pre-existing occupied dwellings. The former is modelled as a set of archetype dwellings with energy end use affected by the relevant set of building regulations that apply during construction. Energy demand of existing dwellings is predicted by a simpler top down method based on historical energy use trends. The baseline scenario suggests residential energy demand will grow by 19% from 3206ktoe in 2007 to 3810ktoe in 2020. The results indicate that 2008 and 2010 building regulations will lead to energy savings of 305ktoe (8.0%) in 2020. Had the 2008 building regulations been introduced in 2002, at the start of the boom, there would be additional savings of 238ktoe (6.7%) in 2020.

D. Dineen; B.P. Gallachir

2011-01-01T23:59:59.000Z

379

General-purpose heat source project and space nuclear safety and fuels program. Progress report  

SciTech Connect (OSTI)

Studies related to the use of /sup 238/PuO/sub 2/ in radioisotopic power systems carried out for the Advanced Nuclear Systems and Projects Division of LASL are presented. The three programs involved are: general-purpose heat source development; space nuclear safety; and fuels program. Three impact tests were conducted to evaluate the effects of a high temperature reentry pulse and the use of CBCF on impact performance. Additionally, two /sup 238/PuO/sub 2/ pellets were encapsulated in Ir-0.3% W for impact testing. Results of the clad development test and vent testing are noted. Results of the environmental tests are summarized. Progress on the Stirling isotope power systems test and the status of the improved MHW tests are indicated. The examination of the impact failure of the iridium shell of MHFT-65 at a fuel pass-through continued. A test plan was written for vibration testing of the assembled light-weight radioisotopic heater unit. Progress on fuel processing is reported.

Maraman, W.J.

1980-02-01T23:59:59.000Z

380

Water-Heating Dehumidifier  

Energy Innovation Portal (Marketing Summaries) [EERE]

A small appliance developed at ORNL dehumidifies air and then recycles heat to warm water in a water heater. The device circulates cool, dry air in summer and warm air in winter. In addition, the invention can cut the energy required to run a conventional water heater by an estimated 50 per cent....

2010-12-08T23:59:59.000Z

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Research at the Building Research Establishment into the Applications of Solar Collectors for Space and Water Heating in Buildings [and Discussion  

Science Journals Connector (OSTI)

...and the E.E.C. Solar space heating is...experimental low energy house laboratories...using conventional solar collectors with interseasonal heat storage and the other a heat pump with an air solar collector. Studies...means of conserving energy in buildings. The...

1980-01-01T23:59:59.000Z

382

Buildings Energy Data Book: 5.7 Appliances  

Buildings Energy Data Book [EERE]

Refrigeration System Shipments, by Type (Including Exports) 1990 2000 2005 2010 Appliance Type (thousands) (thousands) (thousands) ($million) Refrigerator-Freezers (1) 7,317 9,462 9,369 (2) 5,466 Freezers (chest and upright) 1,328 2,007 2,274 1,958 N/A Refrigerated Display Cases 359 347 177 N/A N/A Unit Coolers (3) 178 207 209 N/A 205 Ice-Making Machines (4) 171 385 373 246 636 Water Cooler 253 348 N/A N/A N/A Beverage Vending Machine 229 353 N/A N/A N/A Note(s): Source(s): 2010 Value of Shipments (thousands) 10,665 1) Does not include commercial products value. 2) Standard sized refrigerator-freezers 6.5 cubic feet and over. 3) Includes heat transfer coolers (refrigeration), ceiling, wall-mounted, and floor-mounted unit coolers. 4) Includes self-contained and not self-contained ice-making machines and combination ice/drink dispensers.

383

Design and optimization of the heat rejection system for a liquid cooled thermionic space nuclear reactor power system  

SciTech Connect (OSTI)

The heat transport subsystem for a liquid metal cooled thermionic space nuclear power system was modelled using algorithms developed in support of previous nuclear power system study programs, which date back to the SNAP-10A flight system. The model was used to define the optimum dimensions of the various components in the heat transport subsystem subjected to the constraints of minimizing mass and achieving a launchable package that did not require radiator deployment. The resulting design provides for the safe and reliable cooling of the nuclear reactor in a proven lightweight design.

Moriarty, M.P. (Rocketdyne Division, Rockwell International Corporation, 6633 Canoga Avenue, P.O. Box 7922, Canoga Park, California 91309-7922 (United States))

1993-01-15T23:59:59.000Z

384

Wood and Pellet Heating | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Wood and Pellet Heating Wood and Pellet Heating Wood and Pellet Heating November 25, 2013 - 2:24pm Addthis A wood stove on a stone hearth. | Photo courtesy of ©iStockphoto/King_Louie A wood stove on a stone hearth. | Photo courtesy of ©iStockphoto/King_Louie What does this mean for me? Wood or pellets may be an economical and environmentally sound heating fuel choice. If you live in an area where you can cut your own wood for heating, your fuel will be local and inexpensive. Today you can choose from a new generation of wood- and pellet-burning appliances that are cleaner burning, more efficient, and powerful enough to heat many average-sized, modern homes. Pellet fuel appliances burn small pellets that measure 3/8 to 1 inch in length. Choosing and Installing Wood- and Pellet-Burning Appliances

385

Building America Expert Meeting: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems  

Broader source: Energy.gov [DOE]

The topic of this meeting was 'Recommendations For Applying Water Heaters In Combination Space And Domestic Water Heating Systems.' Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic. The meeting was held at the Westford Regency Hotel, in Westford, Massachusetts on 7/31/2011.

386

Appliance and Equipment Efficiency Standards | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Efficiency Standards Efficiency Standards Appliance and Equipment Efficiency Standards < Back Program Info State Arizona Program Type Appliance/Equipment Efficiency Standards Provider Arizona Department of Commerce '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for which the federal government is not currently developing an efficiency

387

Taunton Municipal Lighting Plant - Residential Energy Star Appliance Rebate  

Broader source: Energy.gov (indexed) [DOE]

Taunton Municipal Lighting Plant - Residential Energy Star Taunton Municipal Lighting Plant - Residential Energy Star Appliance Rebate Program Taunton Municipal Lighting Plant - Residential Energy Star Appliance Rebate Program < Back Eligibility Residential Savings Category Appliances & Electronics Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Refrigerator: $75 Clothes Washer: $50 Room A/C: $25 Dishwashers: $25 Customers of Taunton Municipal Lighting Plant (TMLP) are eligible for rebates on energy efficient appliances for the home. Clothes washers, dishwashers, refrigerators and room AC units are eligible for these incentives, which range from $25 - $75. All equipment must be Energy Star to qualify. View the rebate brochure for more information on procedures and equipment. Customers should send rebate forms to the address provided on

388

Longmont Power and Communications - Residential and Commercial Appliance  

Broader source: Energy.gov (indexed) [DOE]

Longmont Power and Communications - Residential and Commercial Longmont Power and Communications - Residential and Commercial Appliance Rebate Program Longmont Power and Communications - Residential and Commercial Appliance Rebate Program < Back Eligibility Commercial Residential Savings Category Appliances & Electronics Maximum Rebate 50 per appliance. Residential: 1 clothes washer and 1 dishwasher per year Commercial: 3 clothes washers and 3 dishwashers per year Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Dishwasher: $50 Clothes Washer: $50 Provider Customer Service Longmont Power and Communications offers an incentive for its residential and commercial customers to install energy efficient washing machines and dishwashers. The rebate [http://www.ci.longmont.co.us/lpc/pdfs/rebate_appl.pdf application] is

389

Promoting of Appliance Energy Efficiency and Transformation of the  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Promoting of Appliance Energy Efficiency and Transformation of the Promoting of Appliance Energy Efficiency and Transformation of the Refrigerating Appliances Market in Ghana Speaker(s): Essel Ben Hagan Date: October 13, 2009 - 12:00pm Location: 90-3122 As part of the national initiatives to promote energy savings in Ghana, a program is being implemented with the aim to use standards and labels as the main tool for transforming the refrigerators and refrigerator-freezers market in Ghana towards more energy efficient appliances. The program is intended to generate large electricity savings, as well as reduce the associated greenhouse gas emissions. The key initial outcome of the program is the development of the draft Legislative Instrument "Energy Efficiency Standards and Labeling (Refrigerator, Refrigerator-Freezer and Freezer)

390

DOE Issues Final Appliance Test Procedure Rule | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Appliance Test Procedure Rule Appliance Test Procedure Rule DOE Issues Final Appliance Test Procedure Rule December 8, 2006 - 9:46am Addthis WASHINGTON, DC - The U.S. Department of Energy (DOE) today announced a final rule establishing new test procedures and related definitions to determine the energy efficiency of certain residential appliances and commercial equipment. The rulemaking clarifies and codifies the test procedures mandated by the Energy Policy Act (EPAct) of 2005. "These new test procedures are the foundation for standards that will help bring more energy efficient options to the marketplace and result in energy savings for all Americans," said DOE Assistant Secretary for Energy Efficiency and Renewable Energy Andy Karsner. The final rulemaking, which appears in today's Federal Register, will

391

Energy Department Announces January 2006 Deadline for Appliance Standards  

Broader source: Energy.gov (indexed) [DOE]

January 2006 Deadline for Appliance January 2006 Deadline for Appliance Standards Rulemaking Schedules Energy Department Announces January 2006 Deadline for Appliance Standards Rulemaking Schedules November 15, 2005 - 2:47pm Addthis WASHINGTON, DC - The U.S. Department of Energy (DOE) today announced it will present schedules for all appliance rulemaking activities no later than January 31, 2006. The schedules will be developed following a public meeting held today to invite comment on standards scheduling issues. DOE will finalize its standards scheduling plan after consideration of comments received during and following the public meeting. "The Department of Energy's aggressive commitment to present schedules by January 31, 2006, is driven by our desire to speed up the process and

392

Managing Supply Chain Key for Hawaii Appliance Rebate Program | Department  

Broader source: Energy.gov (indexed) [DOE]

Managing Supply Chain Key for Hawaii Appliance Rebate Program Managing Supply Chain Key for Hawaii Appliance Rebate Program Managing Supply Chain Key for Hawaii Appliance Rebate Program August 24, 2010 - 10:00am Addthis Lindsay Gsell Hawaii's appliance rebate program delivered 4,300 rebates to Hawaiians in just three days. And on just the first day of program, almost 4,000 ENERGY STAR qualified refrigerators were sold. Funded by $1.2 million from the American Recovery and Reinvestment Act, the program delivered a proportionate number of $250 ENERGY STAR refrigerator rebates to six of Hawaii's islands: Oahu, Hawaii, Maui, Kauai, Lanai, and Molokai. "It takes a lot of help from manufacturers, distributors, retailers, hauling company, recyclers, advertisers, printers, new reporters, radio stations and television station to create a success story," said Derrick

393

Managing Supply Chain Key for Hawaii Appliance Rebate Program | Department  

Broader source: Energy.gov (indexed) [DOE]

Managing Supply Chain Key for Hawaii Appliance Rebate Program Managing Supply Chain Key for Hawaii Appliance Rebate Program Managing Supply Chain Key for Hawaii Appliance Rebate Program August 24, 2010 - 10:00am Addthis Lindsay Gsell Hawaii's appliance rebate program delivered 4,300 rebates to Hawaiians in just three days. And on just the first day of program, almost 4,000 ENERGY STAR qualified refrigerators were sold. Funded by $1.2 million from the American Recovery and Reinvestment Act, the program delivered a proportionate number of $250 ENERGY STAR refrigerator rebates to six of Hawaii's islands: Oahu, Hawaii, Maui, Kauai, Lanai, and Molokai. "It takes a lot of help from manufacturers, distributors, retailers, hauling company, recyclers, advertisers, printers, new reporters, radio stations and television station to create a success story," said Derrick

394

Energy-Efficient Appliance Manufacturing Tax Credit | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Energy-Efficient Appliance Manufacturing Tax Credit Energy-Efficient Appliance Manufacturing Tax Credit Energy-Efficient Appliance Manufacturing Tax Credit < Back Eligibility Industrial Savings Category Appliances & Electronics Maximum Rebate The aggregate amount of credit allowed for 2011 is $25 million per taxpayer. Certain refrigerators and clothes washers will not add to the aggregate credit amount. See summary below for more details. Program Info Start Date 01/01/2007 Expiration Date 12/31/2013 Program Type Industry Recruitment/Support Rebate Amount Dishwashers: $25 - $75 per unit, varies by energy and water efficiency; Clothes washers: $175 - $225 per unit, varies by type, and energy and water efficiency; Refrigerators: $150 or $200, depending on energy-efficiency rating Provider U.S. Internal Revenue Service

395

Appliance and Equipment Energy Efficiency Standards | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Energy Efficiency Standards Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards < Back Program Info State New York Program Type Appliance/Equipment Efficiency Standards Provider New York State Energy Research and Development Authority '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of products. In general, states which had set standards prior to federal action may enforce their own standards until the federal standards take effect. States that had not set standards prior to federal action must use the federal standards. This summary addresses (1) state appliance standards that will be in place until the federal standards take effect and (2) products for

396

Appliance and Equipment Standards Result in Large Energy, Economic, and  

Broader source: Energy.gov (indexed) [DOE]

Appliance and Equipment Standards Result in Large Energy, Economic, Appliance and Equipment Standards Result in Large Energy, Economic, and Environmental Benefits Appliance and Equipment Standards Result in Large Energy, Economic, and Environmental Benefits Saving Consumers and Businesses Energy and Money by Setting Efficiency Standards Saving Consumers and Businesses Energy and Money by Setting Efficiency Standards The Building Technologies Office (BTO) implements minimum energy conservation standards for more than 50 categories of appliances and equipment. As a result of these standards, energy users saved about $40 billion on their utility bills in 2010. Since 2009, 18 new or updated standards have been issued, which will help increase annual savings by more than 50 percent over the next decade. By 2030, cumulative operating cost

397

DOE Hydrogen Analysis Repository: H2 Fueling Appliances Cost and  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

H2 Fueling Appliances Cost and Performance H2 Fueling Appliances Cost and Performance Project Summary Full Title: H2 Production Infrastructure Analysis - Task 2: Cost and Performance of H2 Fueling Appliances Project ID: 80 Principal Investigator: Brian James Keywords: Costs; steam methane reforming (SMR); autothermal reforming (ATR); hydrogen fueling Purpose The purpose of the analysis was to estimate the capital cost and the resulting cost of hydrogen of several types of methane-fueled hydrogen production systems. A bottoms-up cost analysis was conducted of each system to generate a system design and detailed bill-of-materials. Estimates of the overall capital cost of the hydrogen production appliance were generated. This work supports Systems Analysis Milestone A1. ("Complete techno-economic analysis on production and delivery technologies currently

398

A novel feature extraction method for nonintrusive appliance load monitoring  

Science Journals Connector (OSTI)

Improving energy efficiency by monitoring household electrical consumption is of significant importance with the climate change concerns of the present time. A solution for the electrical consumption management problemis the use of a nonintrusive appliance ...

Khaled Chahine; Khalil El Khamlichi Drissi

2013-01-01T23:59:59.000Z

399

Energy-Efficient Home Appliances Can Save You Money | Department...  

Energy Savers [EERE]

long term, and shop for ENERGY STAR-qualified appliances to get the best energy-efficient products. This week, we showed you how an energy audit can help you identify energy-saving...

400

2012 APPLIANCE EFFICIENCY REGULATIONS Edmund G. Brown Jr., Governor  

E-Print Network [OSTI]

, (California Code of Regulations, Title 20, Sections 1601 through 1608), dated September 2012, contain television adapters, large and small battery charger systems. #12;ii #12;iii TABLE OF CONTENTS Section .........................................................................................................................67 1603 Testing: All Appliances

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Detailed Modeling and Response of Demand Response Enabled Appliances  

SciTech Connect (OSTI)

Proper modeling of end use loads is very important in order to predict their behavior, and how they interact with the power system, including voltage and temperature dependencies, power system and load control functions, and the complex interactions that occur between devices in such an interconnected system. This paper develops multi-state time variant residential appliance models with demand response enabled capabilities in the GridLAB-DTM simulation environment. These models represent not only the baseline instantaneous power demand and energy consumption, but the control systems developed by GE Appliances to enable response to demand response signals and the change in behavior of the appliance in response to the signal. These DR enabled appliances are simulated to estimate their capability to reduce peak demand and energy consumption.

Vyakaranam, Bharat; Fuller, Jason C.

2014-04-14T23:59:59.000Z

402

Kitchen Appliance Upgrades Improve Water Efficiency at DOD Exchange Facilities  

Broader source: Energy.gov [DOE]

Case study details the Exchange (formerly the Army and Air Force Exchange Service), which took a leadership role in kitchen appliance upgrades to improve water efficiency by integrating water efficiency concepts into the organization's overall sustainability plan and objectives.

403

ASKO Appliances: Order (2012-CE-19/2004)  

Broader source: Energy.gov [DOE]

DOE ordered ASKO Appliances, Inc. to pay a $36,500 civil penalty after finding ASKO had failed to certify that certain models of residential dishwashers and clothes washers comply with the applicable energy and water conservation standards.

404

ASKO Appliances: Proposed Penalty (2012-CE-19/2004)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that ASKO Appliances, Inc. failed to certify residential clothes washers and dishwashers as compliant with the applicable energy and water conservation standards.

405

Energy Department Issues New Appliance Efficiency Standards | Department of  

Broader source: Energy.gov (indexed) [DOE]

Issues New Appliance Efficiency Standards Issues New Appliance Efficiency Standards Energy Department Issues New Appliance Efficiency Standards October 18, 2005 - 12:21pm Addthis WASHINGTON, DC -- U.S. Secretary of Energy Samuel W. Bodman announced that a final rule to codify fifteen energy efficiency standards for residential appliances and commercial equipment has been published in the Federal Register today. These standards were established as part of the comprehensive energy bill signed by President Bush on August 8, 2005. "Improving America's energy efficiency has always been a key goal of this Administration's energy policy," Secretary Bodman said. "These new standards will play an important role in helping to improve America's overall energy savings." The rule announced today addresses the following items for which the Energy

406

Report an Appliance Regulation Violation | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

an Appliance Regulation Violation an Appliance Regulation Violation Report an Appliance Regulation Violation The Appliance & Equipment Standards Program in the Office of Energy Efficiency and Renewable Energy sets performance standards for the energy efficiency of many types of consumer products and industrial equipment. Report Violations To report potential violations of those standards, send an email to: energyefficiencyenforcement@hq.doe.gov. Include in your message the type of product and the brand and model number. Please describe why you believe that the product may violate the applicable standard(s). The Office of the Assistant General Counsel for Enforcement investigates all reports of potential noncompliance. DOE will protect the identity of complainants to the maximum extent permitted by law.

407

EIA Energy Efficiency-Appliance Standards and Labeling Links  

U.S. Energy Information Administration (EIA) Indexed Site

Appliance Standards & Labeling Appliance Standards & Labeling Appliance Standards and Labeling Related Links Page Last Modified: August 2010 EIA Links Disclaimer: These pages contain hypertext links to information created and maintained by other public and private organizations. These links provide additional information that may be useful or interesting and are being provided consistent with the intended purpose of the EIA website. EIA does not control or guarantee the accuracy, relevance, timeliness, or completeness of this outside information. EIA does not endorse the organizations sponsoring linked websites, the views they express, or the products and services they offer. Government Agencies U.S. Department of Energy Energy Conservation Program for Consumer Products, test procedures and certification and enforcement requirements for plumbing products; and certification and enforcement requirements for residential appliances; final rule

408

Quantitative Analysis of the Principal-Agent Problem in Commercial Buildings in the U.S.: Focus on Central Space Heating and Cooling  

E-Print Network [OSTI]

10.5 1 ) TBtu (primary energy consumption of 14.6 [ 12.4] 4.0) TBtu (primary energy consumption of 25.5 [ 12.2]Primary Energy Space Heating Space Cooling Figure 2: Higher space conditioning end-use energy consumption

Blum, Helcio

2010-01-01T23:59:59.000Z

409

Thermoelectrics: From Space Power Systems to Terrestrial Waste Heat Recovery Applications  

Broader source: Energy.gov [DOE]

Progress in reliable high temperature segmented thermoelectric devices and potential for producing electricity from waste heat from energy intensive industrial processes and transportation vehicles exhaust are discussed

410

Interaction between building design, management, household and individual factors in relation to energy use for space heating in apartment buildings  

Science Journals Connector (OSTI)

Abstract In Stockholm, 472 multi-family buildings with 7554 dwellings has been selected by stratified random sampling. Information about building characteristics and property management was gathered from each property owners. Energy use for space heating was collected from the utility company. Perceived thermal comfort, household and personal factors were assessed by a standardized self-administered questionnaire, answered by one adult person in each dwelling, and a proportion of each factor was calculated for each building. Statistical analysis was performed by multiple linear regression models with control for relevant factors all at the same time in the model. Energy use for heating was significantly related to the building age, type of building and ventilation, length of time since the last heating adjustment, ownership form, proportion of females, and proportion of occupants expressing thermal discomfort. How beneficial energy efficiency measures will be may depend on the relationship between energy use and factors related to the building and the property maintenance together with household and personal factors, as all these factors interact with each other. The results show that greater focus should be on real estate management and maintenance and also a need for research with a gender perspective on energy use for space heating.

Karin Engvall; Erik Lampa; Per Levin; Per Wickman; Egil fverholm

2014-01-01T23:59:59.000Z

411

Modeling diffusion of electrical appliances in the residential sector  

SciTech Connect (OSTI)

This paper presents a methodology for modeling residential appliance uptake as a function of root macroeconomic drivers. The analysis concentrates on four major energy end uses in the residential sector: refrigerators, washing machines, televisions and air conditioners. The model employs linear regression analysis to parameterize appliance ownership in terms of household income, urbanization and electrification rates according to a standard binary choice (logistic) function. The underlying household appliance ownership data are gathered from a variety of sources including energy consumption and more general standard of living surveys. These data span a wide range of countries, including many developing countries for which appliance ownership is currently low, but likely to grow significantly over the next decades as a result of economic development. The result is a 'global' parameterization of appliance ownership rates as a function of widely available macroeconomic variables for the four appliances studied, which provides a reliable basis for interpolation where data are not available, and forecasting of ownership rates on a global scale. The main value of this method is to form the foundation of bottom-up energy demand forecasts, project energy-related greenhouse gas emissions, and allow for the construction of detailed emissions mitigation scenarios.

McNeil, Michael A.; Letschert, Virginie E.

2009-11-22T23:59:59.000Z

412

Department of Energy Opens Appliance Standards Investigation...  

Broader source: Energy.gov (indexed) [DOE]

Energy announced today that it has opened an investigation to determine whether certain air conditioners and heat pump products manufactured by Air Con International comply with...

413

Catalog of DC Appliances and Power Systems  

E-Print Network [OSTI]

by DC-indifferent electric resistance heating or by DC-and LED lamps Electric resistance heater Incandescentfluorescent or LED) Electric resistance Cooling Motors

Garbesi, Karina

2012-01-01T23:59:59.000Z

414

Space  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy Earth Materials Science Technology The Lab All Paul Johnson Unusual light in dark space revealed by Los Alamos, NASA By looking at the dark spaces between visible...

415

Application analysis of ground source heat pumps in building space conditioning  

E-Print Network [OSTI]

2011. Direct utilization of geothermal energy 2010 worldwide2011. China's Geothermal Energy Utilization. Beijing:The adoption of geothermal energy in space conditioning of

Qian, Hua

2014-01-01T23:59:59.000Z

416

U-247: EMC Cloud Tiering Appliance Flaw Lets Remote Users Bypass  

Broader source: Energy.gov (indexed) [DOE]

7: EMC Cloud Tiering Appliance Flaw Lets Remote Users Bypass 7: EMC Cloud Tiering Appliance Flaw Lets Remote Users Bypass Authentication and Gain Administrative Access U-247: EMC Cloud Tiering Appliance Flaw Lets Remote Users Bypass Authentication and Gain Administrative Access August 29, 2012 - 6:00am Addthis PROBLEM: EMC Cloud Tiering Appliance Flaw Lets Remote Users Bypass Authentication and Gain Administrative Access PLATFORM: EMC Cloud Tiering Appliance (CTA) 7.4 and prior EMC Cloud Tiering Appliance Virtual Edition (CTA/VE) 7.4 and prior EMC Cloud Tiering Appliance (CTA) 9.0 and prior EMC Cloud Tiering Appliance Virtual Edition (CTA/VE) 9.0 and prior ABSTRACT: A vulnerability was reported in EMC Cloud Tiering Appliance. reference LINKS: SecurityTracker Alert ID: 1027448 Bugtraq ID: 55250 EMC.com CVE-2012-2285 IMPACT ASSESSMENT:

417

Development of a coal fired pulse combustor for residential space heating. Technical progress report, July--September 1987  

SciTech Connect (OSTI)

The systematic development of the residential combustion system is divided into three phases. Only Phase I is detailed here. Phase I constitutes the design, fabrication, testing, and evaluation of a pulse combustor sized for residential space heating. Phase II is an optional phase to develop an integrated system including a heat exchanger. Phase III is projected as a field test of the integrated coal-fired residential space heater. The Phase I effort was nearing completion during this reporting period and a final report is in preparation. The configuration testing was completed early in the period and based upon results of the configuration tests, an optimized configuration for the experimental development testing was chosen. The refractory-lined chambers were fabricated and tested from mid-September through early October. The tandem unit was operated on dry micromized coal without support gas or excitation air for periods lasting from one to three hours. Performance was stable and turndown ratios of 3:1 were achieved during the first three-hour test. A early commercial residential heating system configuration has been identified on the basis of the development testing conducted throughout the first phase of this effort. The development effort indicates that the residential unit goals are achievable with some additional product improvement effort to increase carbon burn-out efficiency, reduce CO emissions and develop a reliable and compact dry, ultrafine coal feed system (not included in the present effort).

NONE

1987-12-31T23:59:59.000Z

418

Local Enforcement of Appliance Efficiency Standards and Labeling Program in  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Local Enforcement of Appliance Efficiency Standards and Labeling Program in Local Enforcement of Appliance Efficiency Standards and Labeling Program in China: Progress and Challenges Title Local Enforcement of Appliance Efficiency Standards and Labeling Program in China: Progress and Challenges Publication Type Conference Proceedings Year of Publication 2012 Authors Zheng, Nina, Nan Zhou, Cecilia Fino-Chen, and David Fridley Conference Name 2012 ACEEE Summer Study on Energy Efficiency in Buildings Date Published 06/2012 Conference Location Pacific Grove, California, U.S.A. Keywords appliance energy efficiency, china, labeling, local enforcement, standards Abstract As part of its commitment to promoting and improving the local enforcement of appliance energyefficiency standards and labeling, the China National Institute of Standardization launched the Nationaland Local Enforcement of Energy Efficiency Standards and Labeling program on August 14, 2009. For thisprogram, Jiangsu, Shandong, Sichuan and Shanghai were selected as pilot locations. This paper providesinformation on the local enforcement program's recent background, activities and results as well ascomparison to previous rounds of check-testing in 2006 and 2007. In addition, the paper also offersevaluation on the achievement and weaknesses in the local enforcement scheme and recommendationsbased on international experience.

419

Buildings Energy Data Book: 5.7 Appliances  

Buildings Energy Data Book [EERE]

6 6 Other Major Appliance Efficiencies 2010 Efficiency 2005 Stock 2010 U.S. Average Best Available Residential Appliance Type Parameter (1) Efficiency New Efficiency New Efficiency Dishwashers EF 0.30 0.61 1.13 Clothes Washers (2) MEF 2.00 2.00 3.88 Clothes Dryers (electric) EF 3.01 3.10 3.16 Clothes Dryers (gas) EF 2.67 2.75 3.02 Cooktop (Gas) Cooking Efficiency 0.38 0.40 0.42 2010 1992 Efficiency Stock U.S. Average Best Available Commercial Appliance Type Parameter (1) Efficiency New Efficiency New Efficiency Cooking Equipment: Electric Appliances EF 0.74 N.A. N.A. Gas Appliances EF 0.53 N.A. N.A. Laundry Equipment: Electric Drying EF/COP N.A. N.A. 0.98 Gas Drying EF N.A. N.A. 0.36 Motors EF N.A. N.A. 0.65 Office Equipment: Linear Power Supplies EF N.A. N.A. Switching Power Supplies EF N.A. N.A. Motors EF N.A. N.A. Note(s): Source(s):

420

Heat conduction in systems with Kolmogorov-Arnold-Moser phase space structure  

E-Print Network [OSTI]

We study heat conduction in a billiard channel formed by two sinusoidal walls and the diffusion of particles in the corresponding channel of infinite length; the latter system has an infinite horizon, i.e., a particle can travel an arbitrary distance without colliding with the rippled walls. For small ripple amplitudes, the dynamics of the heat carriers is regular and analytical results for the temperature profile and heat flux are obtained using an effective potential. The study also proposes a formula for the temperature profile that is valid for any ripple amplitude. When the dynamics is regular, ballistic conductance and ballistic diffusion are present. The Poincar\\'e plots of the associated dynamical system (the infinitely long channel) exhibit the generic transition to chaos as ripple amplitude is increased.When no Kolmogorov-Arnold-Moser (KAM) curves are present to forbid the connection of all chaotic regions, the mean square displacement grows asymptotically with time t as tln(t).

I. F. Herrera-Gonzlez; H. I. Prez-Aguilar; A. Mendoza-Surez; E. S Tututi

2012-09-28T23:59:59.000Z

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Overview of DOE-Sponsored Heat Pump Research DOE research activities related to residential and commercial heat pump  

E-Print Network [OSTI]

#12;Overview of DOE-Sponsored Heat Pump Research DOE research activities related to residential and commercial heat pump technology are supported by the Office of Building Energy Research and Development%) allocated to elec- tric and heat-actuated heat pump research. The remaining 15% is allocated to appliance

Oak Ridge National Laboratory

422

General-purpose heat source project and space nuclear safety and fuels program. Progress reportt, January 1980  

SciTech Connect (OSTI)

This formal monthly report covers the studies related to the use of /sup 238/PuO/sub 2/ in radioisotopic power systems carried out for the Advanced Nuclear Systems and Projects Division of the Los Alamos Scientific Laboratory. The two programs involved are the general-purpose heat source development and space nuclear safety and fuels. Most of the studies discussed here are of a continuing nature. Results and conclusions described may change as the work continues. Published reference to the results cited in this report should not be made without the explicit permission of the person in charge of the work.

Maraman, W.J. (comp.)

1980-04-01T23:59:59.000Z

423

Super Cool Appliance Design Wins Student Competition | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Cool Appliance Design Wins Student Competition Cool Appliance Design Wins Student Competition Super Cool Appliance Design Wins Student Competition August 23, 2012 - 2:44pm Addthis The winners of the Max Tech and Beyond competition -- a team of University of Maryland students -- designed and built a prototype for a wall unit air conditioner that showed more than 30 percent energy savings when tested in a lab. | Photo courtesy of Yunho Hwang, University of Maryland. The winners of the Max Tech and Beyond competition -- a team of University of Maryland students -- designed and built a prototype for a wall unit air conditioner that showed more than 30 percent energy savings when tested in a lab. | Photo courtesy of Yunho Hwang, University of Maryland. Rebecca Matulka Rebecca Matulka Digital Communications Specialist, Office of Public Affairs

424

Data Availability in Appliance Standards and Labeling Program  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Data Availability in Appliance Data Availability in Appliance Standards and Labeling Program Development and Evaluation John Romankiewicz, Nina Khanna, Edward Vine, and Nan Zhou China Energy Group Environmental Energy Technologies Division Lawrence Berkeley National Laboratory May 2013 This work was supported by the China Sustainable Energy Program of the Energy Foundation and Collaborative Labeling and Appliance Standards Program through the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. LBNL-6282E Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the University of California, nor any of their employees, makes any

425

Mississippi Residents Save Through Appliance Rebate Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

Residents Save Through Appliance Rebate Program Residents Save Through Appliance Rebate Program Mississippi Residents Save Through Appliance Rebate Program October 27, 2010 - 11:39am Addthis Mississippi's Cowboy Maloney stores saw increases of up to 90 percent on front-loading washing machines in April. | Photo courtesy of Flickr user Andrew Kelsall via the Creative Commons license Mississippi's Cowboy Maloney stores saw increases of up to 90 percent on front-loading washing machines in April. | Photo courtesy of Flickr user Andrew Kelsall via the Creative Commons license Lindsay Gsell What are the key facts? Mississippi rebate program issues 37,430 rebates to residents. Recovery Act helped consumers conserve energy and save millions of dollars. Program demand helps one Mississippi retailer see 90% increase in

426

Updated Buildings Sector Appliance and Equipment Costs and Efficiency  

U.S. Energy Information Administration (EIA) Indexed Site

Updated Buildings Sector Updated Buildings Sector Appliance and Equipment Costs and Efficiency August 2013 Independent Statistics & Analysis www.eia.gov U.S. Department of Energy Washington, DC 20585 U.S. Energy Information Administration | Buildings Appliance and Equipment Costs and Efficiency i This report was prepared by the U.S. Energy Information Administration (EIA), the statistical and analytical agency within the U.S. Department of Energy. By law, EIA's data, analyses, and forecasts are independent of approval by any other officer or employee of the United States Government. The views in this report therefore should not be construed as representing those of the U.S. Department of Energy or other Federal agencies. June 2013 U.S. Energy Information Administration | Buildings Appliance and Equipment Costs and Efficiency 1

427

Midea Washing Appliance: Proposed Penalty (2011-CE-1903) | Department of  

Broader source: Energy.gov (indexed) [DOE]

Proposed Penalty (2011-CE-1903) Proposed Penalty (2011-CE-1903) Midea Washing Appliance: Proposed Penalty (2011-CE-1903) April 22, 2011 DOE alleged in a Notice of Proposed Civil Penalty that Midea Washing Appliances Mfg. Co., Ltd. failed to certify a variety of dishwashers as compliant with the applicable water and energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable water and energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. Midea: Proposed Penalty (2011-CE-1903) More Documents & Publications Midea Washing Appliance: Order (2011-CE-1903)

428

Memorandum from VP Technical Services, Association of Home Appliance  

Broader source: Energy.gov (indexed) [DOE]

from VP Technical Services, Association of Home from VP Technical Services, Association of Home Appliance Manufacturers to the Department of Energy Memorandum from VP Technical Services, Association of Home Appliance Manufacturers to the Department of Energy This memo memorializes the phone call between AHAM and the Department of Energy on November 4, 2009 for inclusion in the public docket. The issues discussed during the call included (1) an update on ice maker energy into the refrigerator (2) freezer test procedure and (3) questions on the status regarding AHAM's clarification request on clothes washer drum volume determination. Memorandum from VP Technical Services, Association of Home Appliance Manufacturers to the Department of Energy More Documents & Publications Ex parte Communication Proceedings of the Computational Needs for the Next Generation Electric

429

Wood and Pellet Heating Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Wood and Pellet Heating Basics Wood and Pellet Heating Basics Wood and Pellet Heating Basics August 16, 2013 - 3:02pm Addthis Wood-burning and pellet fuel appliances use biomass or waste resources to heat homes or buildings. Types of Wood- and Pellet-Burning Appliances The following is a brief overview of the different types of wood and pellet fuel appliances available. High-Efficiency Fireplaces and Fireplace Inserts Designed more for show, traditional open masonry fireplaces should not be considered heating devices. Traditional fireplaces draw in as much as 300 cubic feet per minute of heated room air for combustion, then send it straight up the chimney. Fireplaces also produce significant air pollution. Although some fireplace designs seek to address these issues with dedicated air supplies, glass doors, and heat recovery systems, fireplaces are still

430

Will You Be Purchasing New Appliances for a Rebate from Your...  

Broader source: Energy.gov (indexed) [DOE]

Will You Be Purchasing New Appliances for a Rebate from Your State? Will You Be Purchasing New Appliances for a Rebate from Your State? December 24, 2009 - 7:30am Addthis This...

431

"Table HC10.10 Home Appliances Usage Indicators by U.S. Census...  

U.S. Energy Information Administration (EIA) Indexed Site

0 Home Appliances Usage Indicators by U.S. Census Regions, 2005" " Million U.S. Housing Units" ,"Housing Units (millions)","U.S. Census Region" "Home Appliances Usage...

432

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review ...  

Energy Savers [EERE]

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review Presenter: Tony Bouza, U.S. Department of Energy This...

433

The effects of energy efficiency and environmental labels on appliance choice in SouthKorea  

Science Journals Connector (OSTI)

This paper investigates the effects of energy efficiency and environmental labels on households choice of appliances, using a discrete ... on appliance choice. This paper found that households showed a positive ...

Gicheol Jeong; Yeunjoong Kim

2014-10-01T23:59:59.000Z

434

A Texas Study of the Effects of the National Appliance Energy Conservation Act of 1987  

E-Print Network [OSTI]

At the present time, no legislated efficiency standards exist in Texas for residential appliances. However, the National Appliance Energy Conservation Act (NAECA) of 1987 passed by the U.S. Senate in February, 1987, sets strict nationwide limits...

Bachmeier, R.

1987-01-01T23:59:59.000Z

435

V-021: Cisco IronPort Web / Email Security Appliance Sophos Anti...  

Broader source: Energy.gov (indexed) [DOE]

1: Cisco IronPort Web Email Security Appliance Sophos Anti-Virus Multiple Vulnerabilities V-021: Cisco IronPort Web Email Security Appliance Sophos Anti-Virus Multiple...

436

Refrigerator Efficiency in Ghana: Tailoring an appliance market transformation program design for Africa  

E-Print Network [OSTI]

and organizational long-term commitment to furthering energy efficiency.organizational environment. The approach for appliance energy efficiency

Ben Hagan, Essel; Van Buskirk, Robert; Ofosu-Ahenkorah, Alfred; McNeil, Michael A.

2006-01-01T23:59:59.000Z

437

Energy-efficiency labels and standards: A guidebook for appliances, equipment and lighting  

E-Print Network [OSTI]

Appliance Manufacturers (AHAM) certification program forAuthority of Thailand AEU AGO AHAM AMI ANSI ANOPR APEC ARI

McMahon, James E.; Wiel, Stephen

2001-01-01T23:59:59.000Z

438

Oregon State Energy-Efficiency Appliance Rebate Program Helps Low-Income Families  

Office of Energy Efficiency and Renewable Energy (EERE)

Statewide program provides low-income homeowners with rebates on money-saving, energy-efficient appliances.

439

Comment submitted by BSH Home Appliances Corporation regarding the Energy Star Verification Testing Program  

Broader source: Energy.gov [DOE]

This document is a comment submitted by BSH Home Appliances Corporation regarding the Energy Star Verification Testing Program

440

Max Tech Appliance Design: Potential for Maximizing U.S. Energy Savings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Appliance Design: Potential for Maximizing U.S. Energy Savings Appliance Design: Potential for Maximizing U.S. Energy Savings through Standards Title Max Tech Appliance Design: Potential for Maximizing U.S. Energy Savings through Standards Publication Type Report LBNL Report Number LBNL-4608E Year of Publication 2011 Authors Garbesi, Karina, Louis-Benoit Desroches, Christopher A. Bolduc, Gabriel Burch, Griffin Hosseinzadeh, and Seth Saltiel Document Number LBNL-4608E Pagination 13 Date Published July 11 Publisher Lawrence Berkeley National Laboratory City Berkeley Abstract This study surveyed the technical potential for efficiency improvements in 150 categories of appliances and equipment representing 33 quads of primary energy use across the US economy in 2010 and (1) documented efficient product designs, (2) identified the most promising cross-cutting strategies, and (3) ranked national energy savings potential by end use. Savings were estimated using a method modeled after US Department of Energy priority-setting reports-simplified versions of the full technical and economic analyses performed for rulemakings. This study demonstrates that large savings are possible by replacing products at the end-of-life with ultra-efficient models that use existing technology. Replacing the 50 top energy-saving end-uses (constituting 30 quads of primary energy consumption in 2010) with today's best-on-market equivalents would save ~200 quads of US primary energy over 30 years (25% of consumption anticipated there from). For the 29 products for maximum feasible savings potential could be estimated, the savings were twice as high. These results demonstrate that pushing ultra-efficient products to market could significantly escalate carbon emission reductions and is a viable strategy for sustaining large emissions reductions through standards. The results of this analysis were used by DOE for new coverage prioritization, to identify key opportunities for product prototyping and market development, and will leverage future standards rulemakings by identifying the full scope of maximum feasible technology options. High leverage products include advances lighting systems, HVAC, and televisions. High leverage technologies include electronic lighting, heat pumps, variable speed motors, and a host of controls-related technologies.

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Guide to Geothermal Heat Pumps  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Geothermal Heat Pumps Work Using a heat exchanger, a geothermal heat pump can move heat from one space to another. In summer, the geothermal heat pump extracts heat from a building...

442

Appliance Standards Program Overview- 2014 BTO Peer Review  

Broader source: Energy.gov [DOE]

Presenter: John Cymbalsky, U.S. Department of Energy This presentation at the 2014 Peer Review provided an overview of the Building Technologies Office's Appliance and Equipment Standards Program. Through robust feedback, the BTO Program Peer Review enhances existing efforts and improves future designs.

443

Innovative Concept Appliances: Order (2010-CE-03/0415)  

Broader source: Energy.gov [DOE]

DOE issued an Order after entering into a Compromise Agreement with Innovative Concept Appliances, LLC. to resolve a case involving the failure to certify that a variety of residential clothes washers and clothes dryers comply with the applicable energy conservation standards.

444

Effects of installing economizers in boilers used in space heating applications  

SciTech Connect (OSTI)

This paper discusses how the performance of a boiler can be improved by adding an economizer to preheat the boiler's feedwater. An energy analysis was applied to a boiler and then to both a boiler and an economizer (water pre-heater) to evaluate the benefits of heat recovery. Exergy rates calculated for both the boiler and the economizer determined that the temperature of the stack gases had primary effects on the performance of a boiler. The results from this study showed that 57% of the heat rejected at the boiler's stack could be recovered by installing an economizer to preheat the feedwater. As a result, the average cost savings that would be realized for a 36,400 kg/h (80,000 lbm/h) boiler averages US$8 per hour. The cost savings to steam production averaged US$0.20 per 455 kg (1,000 lbm) of steam and the ration between the cost savings to stack temperature averaged $0.02 per C (1.8 F). For this case, the fuel and the cost savings realized from using an economizer were averaged at 3.8% and 3.7%, respectively. These results translated to total cost savings, for an eight-day period considered, of US$940.

Gonzalez, M.A.; Medina, M.A.; Schruben, D.L.

1999-07-01T23:59:59.000Z

445

Modeling of GE Appliances: Cost Benefit Study of Smart Appliances in Wholesale Energy, Frequency Regulation, and Spinning Reserve Markets  

SciTech Connect (OSTI)

This report is the second in a series of three reports describing the potential of GEs DR-enabled appliances to provide benefits to the utility grid. The first report described the modeling methodology used to represent the GE appliances in the GridLAB-D simulation environment and the estimated potential for peak demand reduction at various deployment levels. The third report will explore the technical capability of aggregated group actions to positively impact grid stability, including frequency and voltage regulation and spinning reserves, and the impacts on distribution feeder voltage regulation, including mitigation of fluctuations caused by high penetration of photovoltaic distributed generation. In this report, a series of analytical methods were presented to estimate the potential cost benefit of smart appliances while utilizing demand response. Previous work estimated the potential technical benefit (i.e., peak reduction) of smart appliances, while this report focuses on the monetary value of that participation. The effects on wholesale energy cost and possible additional revenue available by participating in frequency regulation and spinning reserve markets were explored.

Fuller, Jason C.; Parker, Graham B.

2012-12-31T23:59:59.000Z

446

Energy-Efficient Appliances: Selection and maintenance guidelines for major home appliances (Office of Building Technology, State and Community Programs (BTS) Technology Fact Sheet)  

SciTech Connect (OSTI)

Fact sheet for homeowners and contractors that explains the energy savings potential of efficient appliances, how to purchase them, and how to maintain them.

Southface Energy Institute; U.S. Department of Energy's Oak Ridge National Laboratory

2001-08-15T23:59:59.000Z

447

T-588: HP Virtual SAN Appliance Stack Overflow | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

T-588: HP Virtual SAN Appliance Stack Overflow T-588: HP Virtual SAN Appliance Stack Overflow T-588: HP Virtual SAN Appliance Stack Overflow March 25, 2011 - 5:05pm Addthis PROBLEM: HP Virtual SAN Appliance Stack Overflow in 'hydra.exe' Lets Remote Users Execute Arbitrary Code. PLATFORM: HP StorageWorks P4000 Virtual SAN Appliance Software ABSTRACT: A vulnerability has been reported in HP StorageWorks P4000 Virtual SAN Appliance Software, which can be exploited by malicious people to compromise a vulnerable system. reference LINKS: Secunia advisory 34782 SecurityTracker Alert ID: 1025249 ZDI-11-111 Bugtraq ID: 47005 IMPACT ASSESSMENT: High Discussion: Hewlett-Packard Virtual SAN Appliance is prone to a remote buffer-overflow vulnerability. Attackers may exploit this issue to execute arbitrary code within the context of the affected application. Failed exploit attempts may result in

448

V-021: Cisco IronPort Web / Email Security Appliance Sophos Anti-Virus  

Broader source: Energy.gov (indexed) [DOE]

21: Cisco IronPort Web / Email Security Appliance Sophos 21: Cisco IronPort Web / Email Security Appliance Sophos Anti-Virus Multiple Vulnerabilities V-021: Cisco IronPort Web / Email Security Appliance Sophos Anti-Virus Multiple Vulnerabilities November 12, 2012 - 6:00am Addthis PROBLEM: Cisco IronPort Web / Email Security Appliance Sophos Anti-Virus Multiple Vulnerabilities PLATFORM: Cisco IronPort Email Security Appliances (C-Series and X-Series) running Sophos Engine versions 3.2.07.352_4.80 and prior. Cisco IronPort Web Security Appliances (S-Series) running Sophos Engine versions 3.2.07.352_4.80 and prior. ABSTRACT: Cisco Ironport Appliances Sophos Anti-Virus Vulnerabilities. REFERENCE LINKS: Cisco Security Advisory ID: cisco-sa-20121108-sophos Secunia Advisory SA51197 IMPACT ASSESSMENT: High DISCUSSION: Cisco has acknowledged some vulnerabilities in Cisco IronPort Web Security

449

V-021: Cisco IronPort Web / Email Security Appliance Sophos Anti-Virus  

Broader source: Energy.gov (indexed) [DOE]

1: Cisco IronPort Web / Email Security Appliance Sophos 1: Cisco IronPort Web / Email Security Appliance Sophos Anti-Virus Multiple Vulnerabilities V-021: Cisco IronPort Web / Email Security Appliance Sophos Anti-Virus Multiple Vulnerabilities November 12, 2012 - 6:00am Addthis PROBLEM: Cisco IronPort Web / Email Security Appliance Sophos Anti-Virus Multiple Vulnerabilities PLATFORM: Cisco IronPort Email Security Appliances (C-Series and X-Series) running Sophos Engine versions 3.2.07.352_4.80 and prior. Cisco IronPort Web Security Appliances (S-Series) running Sophos Engine versions 3.2.07.352_4.80 and prior. ABSTRACT: Cisco Ironport Appliances Sophos Anti-Virus Vulnerabilities. REFERENCE LINKS: Cisco Security Advisory ID: cisco-sa-20121108-sophos Secunia Advisory SA51197 IMPACT ASSESSMENT: High DISCUSSION: Cisco has acknowledged some vulnerabilities in Cisco IronPort Web Security

450

U-126: Cisco Adaptive Security Appliances Port Forwarder ActiveX Control  

Broader source: Energy.gov (indexed) [DOE]

26: Cisco Adaptive Security Appliances Port Forwarder ActiveX 26: Cisco Adaptive Security Appliances Port Forwarder ActiveX Control Buffer Overflow Vulnerability U-126: Cisco Adaptive Security Appliances Port Forwarder ActiveX Control Buffer Overflow Vulnerability March 16, 2012 - 7:00am Addthis PROBLEM: Cisco Adaptive Security Appliances Port Forwarder ActiveX Control Buffer Overflow Vulnerability PLATFORM: Cisco Adaptive Security Appliance (ASA) 7.x, Cisco Adaptive Security Appliance (ASA) 8.x, Cisco ASA 5500 Series Adaptive Security Appliances ABSTRACT: A vulnerability was reported in Cisco ASA. A remote user can cause arbitrary code to be executed on the target user's system. reference LINKS: Secunia Advisory SA48422 SecurityTracker Alert ID: 1026799 CVE-2012-0358 IMPACT ASSESSMENT: High Discussion: A remote user can create specially crafted HTML that, when loaded by the

451

Characterization of commercial building appliances. Final report  

SciTech Connect (OSTI)

This study focuses on ``other`` end-uses category. The purpose of this study was to determine the relative importance of energy end-use functions other than HVAC and lighting for commercial buildings, and to identify general avenues and approaches for energy use reduction. Specific energy consuming technologies addressed include non-HVAC and lighting technologies in commercial buildings with significant energy use to warrant detailed analyses. The end-uses include office equipment, refrigeration, water heating, cooking, vending machines, water coolers, laundry equipment and electronics other than office equipment. The building types include offices, retail, restaurants, schools, hospitals, hotels/motels, grocery stores, and warehouses.

Patel, R.F.; Teagan, P.W.; Dieckmann, J.T.

1993-08-01T23:59:59.000Z

452

Building America Case Study: Evaluation of Residential Integrated Space/Water Heat Systems, Illinois and New York (Fact Sheet)  

SciTech Connect (OSTI)

This multi-unit field demonstration of combined space and water heating (combi) systems was conducted to help document combi system installation and performance issues that needed to be addressed through research. The objective of the project was to put commercialized forced-air tankless combi units into the field through local contractors that were trained by manufacturers and GTI staff under the auspices of utility-implemented Emerging Technology Programs. With support from PARR, NYSERDA and other partners, the project documented system performance and installations in Chicago and New York. Combi systems were found to save nearly 200 therms in cold climates at efficiencies between about 80% and 94%. Combi systems using third-party air handler units specially designed for condensing combi system operation performed better than the packaged integrated combi systems available for the project. Moreover, combi systems tended to perform poorly when the tankless water heaters operating at high turn-down ratios. Field tests for this study exposed installation deficiencies due to contractor unfamiliarity with the products and the complexity of field engineering and system tweaking to achieve high efficiencies. Widespread contractor education must be a key component to market expansion of combi systems. Installed costs for combi systems need to come down about 5% to 10% to satisfy total resource calculations for utility-administered energy efficiency programs. Greater sales volumes and contractor familiarity can drive costs down. More research is needed to determine how well heating systems such as traditional furnace/water heater, combis, and heat pumps compare in similar as-installed scenarios, but under controlled conditions.

Not Available

2014-11-01T23:59:59.000Z

453

Laser-induced heating of a multilayered medium resting on a half-space: Part 2 - Moving source  

SciTech Connect (OSTI)

Direct access storage devices (DASDs) are widely used in the computer industry to store and manage data. In conventional magnetic recording, an induction head flying very close to the disk surface alters the polarization of the magnetic field of the disk surface to erase and or write the information on the disk. However, a new technology known as magneto optical recording or optical recording has considerable promise to increase data densities and reliability of data source. In magneto-optical storage, magnetic fields are altered by a laser source, which heats the magnetic medium beyond its Curie point, a temperature at which the magnetic medium loses its magnetization. This domain with zero magnetization is subsequently reversed by using an induction magnet. All these processes take place when the disk is rotating at a very high speed with respect to the laser source. An optical disk is a multilayered medium consisting of a thick glass disk on which many layers of different materials are sputtered, only one layer of which serves as a magnetic medium. Therefore, in this paper, a problem of laser-induced heating of a multilayered medium resting on a half-space is considered when the laser is translation with respect to it. The transient heat conduction equation is solved by employing the Laplace transform in the time domain and the Fourier Transform in the x, y dimension. The resulting ordinary differential equation is solved and the inversion of the Lapplace transform is obtained by a technique developed by Crump. The Fourier inversion is obtained by using a Fast Fourier Transform. The technique developed here is then applied to calculate domain size for recorded bits for a given disk, laser power, source characteristics, and rotational velocity.

Kant, R.; Deckert, K.L. (IBM Research Div., San Jose, CA (USA))

1991-02-01T23:59:59.000Z

454

International Comparative Analysis of Appliance Efficiency Standards &  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

International Comparative Analysis of Appliance Efficiency Standards & International Comparative Analysis of Appliance Efficiency Standards & Labeling Programs: Implications for China Title International Comparative Analysis of Appliance Efficiency Standards & Labeling Programs: Implications for China Publication Type Conference Proceedings Year of Publication 2012 Authors Zhou, Nan, Nina Zheng, David Fridley, and John Romankiewicz Conference Name ACEEE Summer Study on Energy Efficiency in Buildings Date Published 06/2012 Publisher American Council for an Energy-Efficient Economy Keywords appliance, china, china energy, china energy group, energy analysis and environmental impacts department, energy efficiency, policy studies, standards and labeling program Abstract As a growing consumer of household appliances, lighting and electronic products, China has seen a steady rise in residential electricity use with 13% average annual growth since the 1980s. Over the last twenty years, China has implemented a series of new minimum energy performance standards (MEPS) and mandatory and voluntary energy labels to improve appliance energy efficiency. As China begins planning for the next phase of standards and labeling (S&L) program development under the 12th Five Year Plan, an evaluation of recent program developments and future directions is undertaken by drawing upon the experiences and lessons learned of key international S&L program development. Specifically, this study provides in-depth review and comparative analysis of the development and recent advancements in the U.S. MEPS and Energy Star, Australia MEPS and Energy Label, European Union MEPS and Eco-Design Label and Japanese Top Runner programs with China's S&L program. The international comparative analysis focuses on key elements of S&L development including stakeholder participation, program resources, data collection and availability, analytical methods, as well as program implementation and enforcement mechanisms. This study finds that adequate program resources from national and local levels, wide-ranging stakeholder participation, incorporation of various technical and economic analyses in standards development, and program impact evaluations are key features of successful S&L programs and have room for improvement in China. At the same time, however, China has become more proactive than some international programs in areas such as launching check-testing, laboratory round-robin testing and compliance verification for S&L programs.

455

Frameworks for Impact Evaluation of Appliance Standards, Labeling,  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

International Review of International Review of Frameworks for Impact Evaluation of Appliance Standards, Labeling, and Incentives Nan Zhou, John Romankiewicz, Edward Vine, Nina Khanna, and David Fridley China Energy Group Environmental Energy Technologies Division Lawrence Berkeley National Laboratory December 2012 This work was supported by the China Sustainable Energy Program of the Energy Foundation and Collaborative Labeling and Appliance Standards Program through the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. LBNL-6003E Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any

456

Technology Partnerships Are Yielding Reliable, Cost-Saving Appliances |  

Broader source: Energy.gov (indexed) [DOE]

Technology Partnerships Are Yielding Reliable, Cost-Saving Technology Partnerships Are Yielding Reliable, Cost-Saving Appliances Technology Partnerships Are Yielding Reliable, Cost-Saving Appliances November 9, 2011 - 12:01pm Addthis Oak Ridge National Laboratory's facility tests several water heaters at one time. Because of ORNL's accelerated durability testing, they estimate that 10 months of constant operation in its testing facility is comparable to 10 years of service life in a typical residential setting. | Photo courtesy of the Building Technologies Research and Integration Center, ORNL Oak Ridge National Laboratory's facility tests several water heaters at one time. Because of ORNL's accelerated durability testing, they estimate that 10 months of constant operation in its testing facility is comparable to 10

457

Technology Partnerships Are Yielding Reliable, Cost-Saving Appliances |  

Broader source: Energy.gov (indexed) [DOE]

Partnerships Are Yielding Reliable, Cost-Saving Partnerships Are Yielding Reliable, Cost-Saving Appliances Technology Partnerships Are Yielding Reliable, Cost-Saving Appliances November 9, 2011 - 12:01pm Addthis Oak Ridge National Laboratory's facility tests several water heaters at one time. Because of ORNL's accelerated durability testing, they estimate that 10 months of constant operation in its testing facility is comparable to 10 years of service life in a typical residential setting. | Photo courtesy of the Building Technologies Research and Integration Center, ORNL Oak Ridge National Laboratory's facility tests several water heaters at one time. Because of ORNL's accelerated durability testing, they estimate that 10 months of constant operation in its testing facility is comparable to 10 years of service life in a typical residential setting. | Photo courtesy of

458

Utility rebates for ENERGY STAR appliances: Are they effective?  

Science Journals Connector (OSTI)

Abstract We estimate the impact of utility cash rebates on the market share of ENERGY STAR appliances by exploiting the variation in timing and size of rebates across US states. We find that a dollar increase in the population-weighted utility rebate raises the share of ENERGY STAR qualified clothes washers by 0.4%, but does not affect dishwasher and refrigerator shares. Using information on energy saved by an ENERGY STAR appliance and assuming a redemption rate of 40%, the cost per tonne of carbon saved is about $140 for the clothes washers rebate program. The corresponding cost of a megawatt hour saved, about $28, is lower than the estimated cost of building and operating an additional power plant and the average on-peak spot price. We conclude that the ENERGY STAR clothes washers rebate program is, on average, a cost-effective way for utilities to reduce electricity demand.

Souvik Datta; Sumeet Gulati

2014-01-01T23:59:59.000Z

459

Grid Friendly Appliances Load-side Solution for Congestion Management  

SciTech Connect (OSTI)

This paper discusses the effectiveness of deploying grid-friendly{trademark} appliances (GFAs) as a load-side solution for congestion management in a competitive electricity market, with the residential house ventilation and air conditioning (HVAC) load used as an example. A GFA is an appliance that can have a sensor and a controller installed to detect price, voltage, or frequency signals and turn on/off according to certain control logic. By using the congestion price as a signal to shift GFA power consumption from high-price periods to low-price periods to reduce load in load pocket areas, transmission line congestion can be successfully mitigated. The magnitude of GFA load reduction and the location of the GFA resources are critical to relieve congestion on targeted lines while not causing other lines to congest. Simulation results are presented and the impact of implementing price-responsive GFAs on the power grid is also studied.

Lu, Ning; Nguyen, Tony B.

2006-05-21T23:59:59.000Z

460

Buildings Energy Data Book: 5.7 Appliances  

Buildings Energy Data Book [EERE]

3 3 Major Appliance Ownership (Millions of Households and Percent of U.S. Households) Appliance Type Room Air Conditioners 30.2 32% 30.4 31% 26.9 26% 27.4 25% 32.7 29% Refrigerators 91.2 98% 96.8 98% 100.0 96% 104.7 96% 111.6 99% Freezers 42.4 45% 41.9 42% 42.8 41% 36.1 33% 48.5 43% Electric Ranges/Cooktops 58.4 63% 65.3 66% 69.2 66% 71.0 65% 68.8 61% Gas Ranges/Cooktops 36.1 39% 38.3 39% 39.4 38% 42.2 39% 45.1 40% Microwave Ovens 77.2 83% 89.5 91% 94.6 91% 97.2 89% 102.6 91% Clothes Washers 86.4 93% 94.3 95% 96.9 93% 90.1 83% 107.1 95% Electric Clothes Dryers 56.1 60% 60.4 61% 61.8 59% 67.6 62% 69.9 62% Gas Clothes Dryers 19.1 21% 21.1 21% 19.8 19% 20.7 19% 22.6 20% Personal Computers N.A. N.A. 43.5 44% N.A. N.A. N.A. N.A. N.A. N.A. Number of U.S. Households 94.0 98.9 107.0 108.8 112.8 Source(s): Appliance Magazine, U.S. Appliance Industry: Market Share, Life Expectancy & Replacement Market, and Saturation Levels, January 2010, p. 11; AHAM,

Note: This page contains sample records for the topic "appliances space heating" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Report to Congress on Appliance Energy Efficiency Rulemakings  

Broader source: Energy.gov (indexed) [DOE]

Activities Activities Submitted Pursuant to Section 141 of the Energy Policy Act of 2005 and to the Conference Report (109-275) to the FY 2006 Energy and Water Development Appropriations Act U.S. Department of Energy January 2006 January 31, 2006 Table of Contents List of Acronyms ............................................................................................................. iv Executive Summary......................................................................................................... v 1 Introduction .............................................................................................................. 1 2 History of the Appliance Standards Program ..................................................... 3 2.1 Energy Policy and Conservation Act ................................................................. 3

462

An Analysis of the Price Elasticity of Demand for Household Appliances  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

the Price Elasticity of Demand for Household Appliances the Price Elasticity of Demand for Household Appliances Title An Analysis of the Price Elasticity of Demand for Household Appliances Publication Type Report LBNL Report Number LBNL-326E Year of Publication 2008 Authors Dale, Larry L., and Sydny K. Fujita Document Number LBNL-326E Pagination 19 Date Published 02/2008 Publisher Lawrence Berkeley National Laboratory City Berkeley Abstract This article summarizes our study of the price elasticity of demand1 for home appliances, including refrigerators, clothes washers and dishwashers. In the context of increasingly stringent appliance standards, we are interested in what kind of impact the increased manufacturing costs caused by higher efficiency requirements will have on appliance sales. We chose to study this particular set of appliances because data for the elasticity calculation was more readily available for refrigerators, clothes washers, and dishwashers than for other appliances. We begin with a review of the existing economics literature describing the impact of economic variables on the sale of durable goods. We then describe the market for home appliances and changes in it over the past 20 years. We conclude with summary and interpretation of the results of our regression analysis and present estimates of the price elasticity of demand for the three appliances.

463

Effect of rib spacing on heat transfer and friction in a rotating two-pass rectangular (AR=1:2) channel  

E-Print Network [OSTI]

The research focuses on testing the heat transfer enhancement in a channel for different spacing of the rib turbulators. Those ribs are put on the surface in the two pass rectangular channel with an aspect ratio of AR=1:2. The cross section...

Liu, Yao-Hsien

2006-10-30T23:59:59.000Z

464

A 5-1/2-dimensional theory for fast and accurate evaluation of the cyclotron resonance heating using a real-space wave representation  

SciTech Connect (OSTI)

The cyclotron resonance heating rate in a plasma has been evaluated so far from a five-dimensional (5D) quasilinear model because the 6D evaluation is prohibitively expensive. However, the quasilinear approach as applied to the cyclotron resonance heating has fundamental difficulties in evaluating the net effect from a large number of coupled wave modes (leading to strong spatial wave inhomogeneity) since the theory is built on the Fourier space wave representation, and does not include the regular nonlinear particle dynamics within a resonance passing event since the theory is based on the unperturbed orbit theory. A new 5-1/2D theory is formulated for evaluation of a more accurate resonant particle dynamics using the real-space wave representation, which overcomes the shortcomings of the quasilinear cyclotron resonance heating theories by reproducing the 6D physics at the 5D computing speed.

Park, Gunyoung; Chang, C. S. [Courant Institute of Mathematical Sciences, New York University, New York, New York 10012 and National Fusion Research Center, Daejeon 305-333 (Korea, Republic of); Courant Institute of Mathematical Sciences, New York University, New York, New York 10012 (United States) and Department of Physics, Korea Advanced Institute of Science and Technology, Daejeon 305-701 (Korea, Republic of)

2007-05-15T23:59:59.000Z

465

Developing Anthropogenic Heating Profiles for Urban Areas Across the United States  

E-Print Network [OSTI]

and approximate state-wide fuel efficiency. Heat added by buildings take into account electricity (e.g., AC systems, appliances) and heating fuel usage. The building component relies on both population and climate, as heating and cooling degree days are proportional to the amount of heating fuel and electricity used

Hall, Sharon J.

466

Cooking Appliance Use in California Homes - Data Collected from a  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Cooking Appliance Use in California Homes - Data Collected from a Cooking Appliance Use in California Homes - Data Collected from a Web-Based Survey Title Cooking Appliance Use in California Homes - Data Collected from a Web-Based Survey Publication Type Report LBNL Report Number LBNL-5028E Year of Publication 2011 Authors Klug, Victoria L., Agnes B. Lobscheid, and Brett C. Singer Date Published August 2011 Publisher Lawrence Berkeley National Laboratory City Berkeley, CA Keywords Range Hood Test Facility Abstract Cooking of food and use of natural gas cooking burners generate pollutants that can have substantial impacts on residential indoor air quality. The extent of these impacts depends on cooking frequency, duration and specific food preparation activities in addition to the extent to which exhaust fans or other ventilation measures (e.g. windows) are used during cooking. With the intent of improving our understanding of indoor air quality impacts of cooking-related pollutants, we created, posted and advertised a web-based survey about cooking activities in residences. The survey included questions similar to those in California's Residential Appliance Saturation Survey (RASS), relating to home, household and cooking appliance characteristics and weekly patterns of meals cooked. Other questions targeted the following information not captured in the RASS: (1) oven vs. cooktop use, the number of cooktop burners used and the duration of burner use when cooking occurs, (2) specific cooking activities, (3) the use of range hood or window to increase ventilation during cooking, and (4) occupancy during cooking. Specific cooking activity questions were asked about the prior 24 hours with the assumption that most people are able to recollect activities over this time period. We examined inter-relationships among cooking activities and patterns and relationships of cooking activities to household demographics. We did not seek to obtain a sample of respondents that is demographically representative of the California population but rather to inexpensively gather information from homes spanning ranges of relevant characteristics including the number of residents and presence or absence of children. This report presents the survey, the responses obtained, and limited analysis of the results.

467

Buying an Appliance this Holiday Season? ENERGY STAR Products will Save You  

Broader source: Energy.gov (indexed) [DOE]

Buying an Appliance this Holiday Season? ENERGY STAR Products will Buying an Appliance this Holiday Season? ENERGY STAR Products will Save You Money and Energy All Year! Buying an Appliance this Holiday Season? ENERGY STAR Products will Save You Money and Energy All Year! December 12, 2012 - 11:40am Addthis When shopping for appliances or electronics for the holidays, look for the ENERGY STAR® and EnergyGuide labels. | Photo by Dennis Schroeder, NREL 22090. When shopping for appliances or electronics for the holidays, look for the ENERGY STAR® and EnergyGuide labels. | Photo by Dennis Schroeder, NREL 22090. Erin Connealy Communications Specialist, Office of Energy Efficiency and Renewable Energy How can I participate? Look for the ENERGY STAR® label to find energy-efficient appliances. It's the holiday season, which is a perfect time to find a great deal on

468