National Library of Energy BETA

Sample records for annual pv shipments

  1. Annual Transportation Report for Radioactive Waste Shipments to and from the Nevada Test Site, Fiscal Year 2009

    SciTech Connect (OSTI)

    U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office

    2010-02-01

    In February 1997, the U.S. Department of Energy (DOE), Nevada Operations Office (now known as the Nevada Site Office) issued the Mitigation Action Plan which addressed potential impacts described in the “Final Environmental Impact Statement for the Nevada Test Site and Off-Site Locations in the State of Nevada” (DOE/EIS 0243). The DOE, Nevada Operations Office committed to several actions, including the preparation of an annual report, which summarizes waste shipments to and from the Nevada Test Site (NTS) Radioactive Waste Management Site (RWMS) at Area 5 and Area 3. Since 2006, the Area 3 RWMS has been in cold stand-by. This document satisfies requirements regarding low-level radioactive waste (LLW) and mixed low-level radioactive waste (MLLW) transported to and from the NTS during FY 2009. In addition, this document provides shipment, volume, and route information on transuranic (TRU) waste shipped from the NTS to the Idaho National Laboratory, near Idaho Falls, Idaho.

  2. NREL/SCE High Penetration PV Integration Project: FY13 Annual Report

    SciTech Connect (OSTI)

    Mather, B. A.; Shah, S.; Norris, B. L.; Dise, J. H.; Yu, L.; Paradis, D.; Katiraei, F.; Seguin, R.; Costyk, D.; Woyak, J.; Jung, J.; Russell, K.; Broadwater, R.

    2014-06-01

    In 2010, the National Renewable Energy Laboratory (NREL), Southern California Edison (SCE), Quanta Technology, Satcon Technology Corporation, Electrical Distribution Design (EDD), and Clean Power Research (CPR) teamed to analyze the impacts of high penetration levels of photovoltaic (PV) systems interconnected onto the SCE distribution system. This project was designed specifically to benefit from the experience that SCE and the project team would gain during the installation of 500 megawatts (MW) of utility-scale PV systems (with 1-5 MW typical ratings) starting in 2010 and completing in 2015 within SCE's service territory through a program approved by the California Public Utility Commission (CPUC). This report provides the findings of the research completed under the project to date.

  3. Enabling Broad Adoption of Distributed PV-storage systems Via Supervisory Planning & Control

    E-Print Network [OSTI]

    DeForest, Nicholas

    2014-01-01

    of distributed PV-storage systems via supervisory planning &of distributed PV-storage systems via supervisory planning &control for PV-storage systems increases the annual energy

  4. PV Value®

    Office of Energy Efficiency and Renewable Energy (EERE)

    PV Value® is a free solar PV Valuation tool that answers the question of "How much is solar PV worth" and is compliant with the Uniform Standards of Professional Appraisal Practice. It is available for and being used by real estate appraisers, realtors, homeowners, commercial building owners, home builders, solar installers, green raters, insurance companies, and mortgage lenders in all 50 states along with D.C. and Puerto Rico. PV Value® allows for the calculation of both the cost and income approach to value and was endorsed by the largest appraiser trade organization, the "Appraisal Institute," as an innovative approach to valuing solar assets.

  5. Fsica V 2014 NOTURNO Cdigo Nome PV-1 PV-2 PV-3 PV-4 PV-5 PV-6 P-1 P-2 Mdia Freq. SUB

    E-Print Network [OSTI]

    Ribas, Roberto Vicençotto

    Física V ­ 2014 NOTURNO Código Nome PV-1 PV-2 PV-3 PV-4 PV-5 PV-6 P-1 P-2 Média Freq. SUB 5484455

  6. Sandia Energy - PV Value®

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and PV industry sales staff. For appraisers, the inputs specific to PV in the Residential Green and Energy Efficient Addendum can be used as inputs to PV Value. Valuing a PV...

  7. Supported PV module assembly

    SciTech Connect (OSTI)

    Mascolo, Gianluigi; Taggart, David F.; Botkin, Jonathan D.; Edgett, Christopher S.

    2013-10-15

    A supported PV assembly may include a PV module comprising a PV panel and PV module supports including module supports having a support surface supporting the module, a module registration member engaging the PV module to properly position the PV module on the module support, and a mounting element. In some embodiments the PV module registration members engage only the external surfaces of the PV modules at the corners. In some embodiments the assembly includes a wind deflector with ballast secured to a least one of the PV module supports and the wind deflector. An array of the assemblies can be secured to one another at their corners to prevent horizontal separation of the adjacent corners while permitting the PV modules to flex relative to one another so to permit the array of PV modules to follow a contour of the support surface.

  8. LNG shipments in 1994 set records

    SciTech Connect (OSTI)

    1996-01-15

    Worldwide LNG shipments by ocean-going vessels in 1994 increased to 1,619 voyages, according to an LNG shipping industry statistical annual. LNG Log 20 published the recently compiled 1994 data in the last quarter of 1995. The publication is from the Society of International Gas Tanker and Terminal Operators Ltd., London. The year`s total was 8.8% more than for 1993 and the most in 35 years of records. The trips were made and the vessels loaded and discharged without report of serious safety or environmental incident, says the publication. Of the voyages completed during the year, 596 were to European receiving terminals (up 2.8% over 1993), and 1,003 went to the Far East (an increase of 10.7%); shipments to the US, however, dropped to 20, from 32 in 1993. This paper shows that the 1,619 voyages represent 3.6 million nautical miles logged by 78 vessels active during the year. These ships pumped ashore record annual volumes of approximately 144.3 million cu m of LNG, 110.1 million cu m (76.3%) of which went to Far Eastern customers. The paper also summarizes containment systems in use in 1994 and since LNG began to be shipped in 1959.

  9. Energy 101: Solar PV

    SciTech Connect (OSTI)

    2011-01-01

    Solar photovoltaic (PV) systems can generate clean, cost-effective power anywhere the sun shines. This video shows how a PV panel converts the energy of the sun into renewable electricity to power homes and businesses.

  10. Energy 101: Solar PV

    Office of Energy Efficiency and Renewable Energy (EERE)

    Solar photovoltaic (PV) systems can generate clean, cost-effective power anywhere the sun shines. This video shows how a PV panel converts the energy of the sun into renewable electricity to power...

  11. Energy 101: Solar PV

    ScienceCinema (OSTI)

    None

    2013-05-29

    Solar photovoltaic (PV) systems can generate clean, cost-effective power anywhere the sun shines. This video shows how a PV panel converts the energy of the sun into renewable electricity to power homes and businesses.

  12. Accelerating PV Cost Effectiveness Through Systems Design, Engineering, and Quality Assurance: Phase I Annual Technical Report, 4 November 2004 - 3 November 2005

    SciTech Connect (OSTI)

    Botkin, J.

    2006-07-01

    During Phase I of this PV Manufacturing R&D subcontract, PowerLight Corporation has made significant progress toward the reduction of installed costs for commercial-scale, rooftop PV systems. PowerLight has worked to reduce operating costs by improving long-term reliability and performance through the development of more sophisticated tools used in system design and monitoring. Additionally, PowerLight has implemented design improvements with the goal of reducing cost while maintaining and/or improving product quality. As part of this effort, PowerLight also modified manufacturing and shipping processes to accommodate these design changes, streamline material flow, reduce cost, and decrease waste streams. During Phase II of this project, PowerLight plans to continue this work with the goal of reducing system cost and improving system performance.

  13. Annual Transportation Report for Radioactive Waste Shipments...

    National Nuclear Security Administration (NNSA)

    which routes transporters used to reach the NTS. These reports may be found on the Internet at http:www.nv.doe.govemprogramsenvironmentwastemanagementquarterlyrepo...

  14. City of Shasta Lake Electric Utility- PV Rebate Program

    Broader source: Energy.gov [DOE]

    City of Shasta Lake Electric Utility is providing rebates to their customers for the purchase of photovoltaic (PV) systems. The rebate levels will decrease annually over the life of the program. ...

  15. Impact of Soiling and Pollution on PV Generation Performance

    Broader source: Energy.gov [DOE]

    This 5-page technical letter addresses air pollution effects on PV performance by quantifying, based on a literature search, the average annual loss due to soiling, the impact of cleaning, and a recommended cleaning schedule.

  16. Info for Shipment Requests -------Original Message --------

    E-Print Network [OSTI]

    Movileanu, Liviu

    , Certified, etc. and insure it as well). Please note: Any prepaid shipment with label can be placed

  17. Waste shipment engineering data management plan

    SciTech Connect (OSTI)

    Marquez, D.L.

    1995-05-01

    This plan documents current data management practices and future data management improvements for TWRS Waste Shipment Engineering.

  18. Stabilized PV system

    DOE Patents [OSTI]

    Dinwoodie, Thomas L. (Piedmont, CA)

    2002-12-17

    A stabilized PV system comprises an array of photovoltaic (PV) assemblies mounted to a support surface. Each PV assembly comprises a PV module and a support assembly securing the PV module to a position overlying the support surface. The array of modules is circumscribed by a continuous, belt-like perimeter assembly. Cross strapping, extending above, below or through the array, or some combination of above, below and through the array, secures a first position along the perimeter assembly to at least a second position along the perimeter assembly thereby stabilizing the array against wind uplift forces. The first and second positions may be on opposite sides on the array.

  19. PERFORMANCE ASSESSMENT OF PV MODULES RELATIONSHIP BETWEEN STC RATING AND FIELD PERFORMANCE

    E-Print Network [OSTI]

    Sites, James R.

    PERFORMANCE ASSESSMENT OF PV MODULES ­ RELATIONSHIP BETWEEN STC RATING AND FIELD PERFORMANCE Marko USA ABSTRACT PV module field performance can be assessed by annual effective efficiency and module performance ratio and present results for six PV modules at two locations and different tilts. Results

  20. EFFECTIVE EFFICIENCY AND PERFORMANCE RATIO AS ENERGY RATING SYSTEM FOR PV MODULES Marko Topic1

    E-Print Network [OSTI]

    Sites, James R.

    EFFECTIVE EFFICIENCY AND PERFORMANCE RATIO AS ENERGY RATING SYSTEM FOR PV MODULES Marko Topic1 USA ABSTRACT: PV module energy rating assessment can be expressed by an annual effective efficiency approaches are presented: (i) a more accurate one with hourly averaged data over a year and a model of PV

  1. Fire resistant PV shingle assembly

    SciTech Connect (OSTI)

    Lenox, Carl J.

    2012-10-02

    A fire resistant PV shingle assembly includes a PV assembly, including PV body, a fire shield and a connection member connecting the fire shield below the PV body, and a support and inter-engagement assembly. The support and inter-engagement assembly is mounted to the PV assembly and comprises a vertical support element, supporting the PV assembly above a support surface, an upper interlock element, positioned towards the upper PV edge, and a lower interlock element, positioned towards the lower PV edge. The upper interlock element of one PV shingle assembly is inter-engageable with the lower interlock element of an adjacent PV shingle assembly. In some embodiments the PV shingle assembly may comprise a ventilation path below the PV body. The PV body may be slidably mounted to the connection member to facilitate removal of the PV body.

  2. PV PLANNER A DESIGN AND

    E-Print Network [OSTI]

    Delaware, University of

    PV PLANNER A DESIGN AND ANALYSIS TOOL FOR BUILDING INTEGRATED SOLAR ELECTRIC SYSTEMS FINAL Center for Energy and Environmental Policy University of Delaware December 2006 #12;#12;PV...............................................................................................................................1 1.2 PV Planner: An Overview

  3. 1 1.07 1 500 5297.01 0.07 v PV Qa Q i ...

    E-Print Network [OSTI]

    Owner

    2015-09-24

    Sep 24, 2015 ... CPT PV. = = = = -. 4. Calculate the accumulated value of an annuity immediate with annual payments of 600 for the next. 25 years using an ...

  4. Removing nuclear waste, one shipment at a time

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Removing nuclear waste, one shipment at a time Removing nuclear waste, one shipment at a time The Lab's 1,000th shipment of transuranic waste recently left Los Alamos, on its way...

  5. PV performance modeling workshop summary report.

    SciTech Connect (OSTI)

    Stein, Joshua S.; Tasca, Coryne Adelle (SRA International, Inc., Fairfax, VA); Cameron, Christopher P.

    2011-05-01

    During the development of a solar photovoltaic (PV) energy project, predicting expected energy production from a system is a key part of understanding system value. System energy production is a function of the system design and location, the mounting configuration, the power conversion system, and the module technology, as well as the solar resource. Even if all other variables are held constant, annual energy yield (kWh/kWp) will vary among module technologies because of differences in response to low-light levels and temperature. A number of PV system performance models have been developed and are in use, but little has been published on validation of these models or the accuracy and uncertainty of their output. With support from the U.S. Department of Energy's Solar Energy Technologies Program, Sandia National Laboratories organized a PV Performance Modeling Workshop in Albuquerque, New Mexico, September 22-23, 2010. The workshop was intended to address the current state of PV system models, develop a path forward for establishing best practices on PV system performance modeling, and set the stage for standardization of testing and validation procedures for models and input parameters. This report summarizes discussions and presentations from the workshop, as well as examines opportunities for collaborative efforts to develop objective comparisons between models and across sites and applications.

  6. Portsmouth Site Delivers First Radioactive Waste Shipment to...

    Office of Environmental Management (EM)

    Portsmouth Site Delivers First Radioactive Waste Shipment to Disposal Facility in Texas Portsmouth Site Delivers First Radioactive Waste Shipment to Disposal Facility in Texas...

  7. Research of PV Application on

    E-Print Network [OSTI]

    Netoff, Theoden

    Research of PV Application on UMore Park Community Design Arch 8563:Getting Blow the Surface Xiaoyu Liu #12;Getting Blow Surface: PV opportunity on the UMore Park 2 Research of PV application on U More community on the aspect of PV application. There are four parts in this report: (1) Introduction of UMore

  8. WIPP - Shipment & Disposal Information

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefieldSulfateSciTechtail.Theory ofDidDevelopmentat LENA|UpcomingVisit UsNews ThisPrivacy Act QuickShipment

  9. Grid integrated distributed PV (GridPV).

    SciTech Connect (OSTI)

    Reno, Matthew J.; Coogan, Kyle

    2013-08-01

    This manual provides the documentation of the MATLAB toolbox of functions for using OpenDSS to simulate the impact of solar energy on the distribution system. The majority of the functions are useful for interfacing OpenDSS and MATLAB, and they are of generic use for commanding OpenDSS from MATLAB and retrieving information from simulations. A set of functions is also included for modeling PV plant output and setting up the PV plant in the OpenDSS simulation. The toolbox contains functions for modeling the OpenDSS distribution feeder on satellite images with GPS coordinates. Finally, example simulations functions are included to show potential uses of the toolbox functions. Each function in the toolbox is documented with the function use syntax, full description, function input list, function output list, example use, and example output.

  10. Open PV Project: Unlocking PV Installation Data (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2012-04-01

    This brochure summarizes the Open PV Project, a collaborative effort of government, industry, and the public to compile a comprehensive database of PV installations in the United States. The brochure outlines the purpose and history of the project as well as the main capabilities and benefits of the online Open PV tool. The brochure also introduces how features of the tool are used, and it describes the sources and characteristics of Open PV's data and data collection processes.

  11. Ukiah Utilities- PV Buydown Program

    Broader source: Energy.gov [DOE]

    Through Ukiah Utilities’ PV Buydown Program, residential and commercial customers are eligible for a $1.40-per-watt AC rebate on qualifying grid-connected PV systems up to a maximum system size of...

  12. Sandia Energy - PV Systems Reliability

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Home Stationary Power Energy Conversion Efficiency Solar Energy Photovoltaics PV Systems Reliability PV Systems ReliabilityCoryne Tasca2015-05-08T03:40:54+00:00 Sandia...

  13. Solar PV and Glare Factsheet

    Broader source: Energy.gov [DOE]

    A common misconception about solar photovoltaic (PV) panels is that they inherently cause or create "too much" glare, posing a nuisance to neighbors and a safety risk for pilots. While solar PV systems can produce glare, light absorption - rather than reflection - is central to the function of solar PV panels. This fact sheet describes the basic issues surrounding glare from solar PV panels, the new Federal Aviation Administration guidance, and the implications for local governments.

  14. Testing for PV Reliability (Presentation)

    SciTech Connect (OSTI)

    Kurtz, S.; Bansal, S.

    2014-09-01

    The DOE SUNSHOT workshop is seeking input from the community about PV reliability and how the DOE might address gaps in understanding. This presentation describes the types of testing that are needed for PV reliability and introduces a discussion to identify gaps in our understanding of PV reliability testing.

  15. Characterizing Shading Losses on Partially Shaded PV Systems (Presentation)

    SciTech Connect (OSTI)

    Deline, C.

    2010-09-23

    Presentation on shaded PV power loss, practical issues with modeling shaded PV, and methods of implementing partially shaded PV modeling.

  16. Berkeley Program Offers New Option for Financing Residential PV Systems

    E-Print Network [OSTI]

    Bolinger, Mark A

    2009-01-01

    Vehicle for Residential PV Installations: Opportunities andfor Financing Residential PV Systems Mark Bolinger, Lawrencefor residential photovoltaic (PV) systems. Though financing

  17. Removing nuclear waste, one shipment June 26, 2012

    E-Print Network [OSTI]

    shipments that have been transported to WIPP this year. #12;- 2 - A milestone to be proud of Laboratory

  18. Full Steam Ahead for PV in US Homes?

    E-Print Network [OSTI]

    Bolinger, Mark A

    2009-01-01

    Full Steam Ahead for PV in US Homes? Mark Bolinger, Galenutility-scale photovoltaic (PV) installations in the yearsimplications for PV rebate program administrators, PV system

  19. Overseas shipments of 48Y cylinders

    SciTech Connect (OSTI)

    Tanaka, R.T.; Furlan, A.S. [Cameco Corp., Port Hope, Ontario (Canada)

    1991-12-31

    This paper describes experiences with two incidents of overseas shipments of uranium hexafluoride (UF{sub 6}) cylinders. The first incident involved nine empty UF{sub 6} cylinders in enclosed sea containers. Three UF{sub 6} cylinders broke free from their tie-downs and damaged and contaminated several sea containers. This paper describes briefly how decontamination was carried out. The second incident involved a shipment of 14 full UF{sub 6} cylinders. Although the incident did not cause an accident, the potential hazard was significant. The investigation of the cause of the near accident is recounted. Recommendations to alleviate future similar incidents for both cases are presented.

  20. Outdoor PV Degradation Comparison

    SciTech Connect (OSTI)

    Jordan, D. C.; Smith, R. M.; Osterwald, C. R.; Gelak, E.; Kurtz, S. R.

    2011-02-01

    As photovoltaic (PV) penetration of the power grid increases, it becomes vital to know how decreased power output; may affect cost over time. In order to predict power delivery, the decline or degradation rates must be determined; accurately. At the Performance and Energy Rating Testbed (PERT) at the Outdoor Test Facility (OTF) at the; National Renewable Energy Laboratory (NREL) more than 40 modules from more than 10 different manufacturers; were compared for their long-term outdoor stability. Because it can accommodate a large variety of modules in a; limited footprint the PERT system is ideally suited to compare modules side-by-side under the same conditions.

  1. Sandia Energy - PV Publications

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II)Geothermal Energy &WaterNew CREWOnline Abstracts andPV

  2. Idaho, Navy, DOE agree on shipments to, from INEL

    SciTech Connect (OSTI)

    Tompkins, B.

    1995-12-01

    This report describes aspects of a legal agreement between the U.S. Navy, the state of Idaho, and the United States Department of Energy (US DOE) regarding shipments of radioactive wastes. The agreement will allow for the shipment of 244 spent fuel shipments from the Fort St Vrain facility in Colorado, if a repository or interim storage facility outside Idaho is open and accepting spent fuel from INEL. The number of shipments to the INEL will be limited to 1133, instead of the 1940 originally planned. The Navy will be allowed 575 total shipments through the year 2035.

  3. Public information circular for shipments of irradiated reactor fuel

    SciTech Connect (OSTI)

    1996-07-01

    This circular provides information on shipment of spent fuel subject to regulation by US NRC. It provides a brief description of spent fuel shipment safety and safeguards requirement of general interest, a summary of data for 1979-1995 highway and railway shipments, and a listing, by State, of recent highway and railway shipment routes. The enclosed route information reflects specific NRC approvals that have been granted in response to requests for shipments of spent fuel. This publication does not constitute authority for carriers or other persons to use the routes described to ship spent fuel, other categories of nuclear waste, or other materials.

  4. Radiation Center and TRIGA Report Annual Report

    E-Print Network [OSTI]

    2 Monthly Summary of Liquid Effluent Releases to the Sanitary Sewer 33 V 3 Annual Summary of Liquid Survey Data 30 Radioactive Material Shipments 31 References 31 Part VI--Work Summary 50 Teaching 50 Waste Generated and Transferred 34 V 4 Monthly Summary of Gaseous Effluent Releases 35 V 5 Annual

  5. PV ENERGY ROI Tracks Efficiency Gains

    E-Print Network [OSTI]

    PV ENERGY ROI Tracks Efficiency Gains the state of PV today E nergy payback time (EPBT) is the time it takes for a photovoltaic (PV) system to produce all the energy used through- out its life cycle. A short, current com- mercial PV technologies "pay back" the energy used in only six months to two years (depending

  6. Rooftop Solar PV & Firefighter Safety

    Office of Energy Efficiency and Renewable Energy (EERE)

    Solar photovoltaic (PV) installations have experienced significant growth in recent years. Due to technological innovations and cost reductions, solar energy is a viable option for an increasing number of residences and businesses across the United States. Rooftop solar is considered safe – to date there has been no documented case of death from the electric shock, chemical burn or conventional fire caused by a solar panel; however, as more buildings install rooftop solar systems, the likelihood increases that fires will occur on buildings with solar, making it critical for firefighters to receive comprehensive solar education and training. This SolarOPs fact sheet gives a brief overview of typical solar PV installations, addresses the major hazards and risks to firefighters, discusses fire safety in Germany (the country with the most installed solar PV per capita), and suggests recommendations and resources to ensure that first responders are prepared to fight fires on homes and buildings with rooftop solar PV.

  7. Turlock Irrigation District- PV Rebate

    Office of Energy Efficiency and Renewable Energy (EERE)

    Turlock Irrigation District (TID) offers an incentive program to their customers who install solar photovoltaic (PV) systems. In keeping with the terms of the California Solar Initiative, the inc...

  8. Scenes for Chancellors Report- PV 

    E-Print Network [OSTI]

    Unknown

    2011-08-17

    Syringopeptin (syp) and syringomycin (syr) are major necrosis-inducing lipodepsipeptide phytotoxins produced by P. syringae pv. syringae. This report demonstrates that syringopeptin production is activated by plant signal ...

  9. Construction of Ag Building- PV 

    E-Print Network [OSTI]

    Unknown

    2011-08-17

    Pseudomonas syringae pv. syringae strain B728a (P.s.s. B728a) is an economically significant plant pathogen that is capable of successful epiphytic colonization of leaf surfaces. Although the virulence factors associated ...

  10. Pressure-equalizing PV assembly and method

    DOE Patents [OSTI]

    Dinwoodie, Thomas L.

    2004-10-26

    Each PV assembly of an array of PV assemblies comprises a base, a PV module and a support assembly securing the PV module to a position overlying the upper surface of the base. Vents are formed through the base. A pressure equalization path extends from the outer surface of the PV module, past the PV module, to and through at least one of the vents, and to the lower surface of the base to help reduce wind uplift forces on the PV assembly. The PV assemblies may be interengaged, such as by interengaging the bases of adjacent PV assemblies. The base may include a main portion and a cover and the bases of adjacent PV assemblies may be interengaged by securing the covers of adjacent bases together.

  11. PV module mounting method and mounting assembly

    DOE Patents [OSTI]

    Lenox, Carl J.S.; Johnson, Kurt M.

    2013-04-23

    A method for mounting PV modules to a deck includes selecting PV module layout pattern so that adjacent PV module edges are spaced apart. PV mounting and support assemblies are secured to the deck according to the layout pattern using fasteners extending into the deck. The PV modules are placed on the PV mounting and support assemblies. Retaining elements are located over and secured against the upper peripheral edge surfaces of the PV modules so to secure them to the deck with the peripheral edges of the PV modules spaced apart from the deck. In some examples a PV module mounting assembly, for use on a shingled deck, comprises flashing, a base mountable on the flashing, a deck-penetrating fastener engageable with the base and securable to the deck so to secure the flashing and the base to the shingled deck, and PV module mounting hardware securable to the base.

  12. Connecticut Rooftop Solar PV Permitting Guide

    Broader source: Energy.gov [DOE]

    The Connecticut Rooftop Solar PV Permitting Guide is a compilation of best practices and resources for solar PV permitting. The guide includes a summary of current codes and regulations affecting solar PV, best practices for streamlining the municipal permitting process, and tools to assist municipalities in creating a streamlined permit process for residential solar PV. Resources include a solar PV permit application, a structural review worksheet, an inspection checklist, and a model solar zoning ordinance.

  13. PSCAD Modules Representing PV Generator

    SciTech Connect (OSTI)

    Muljadi, E.; Singh, M.; Gevorgian, V.

    2013-08-01

    Photovoltaic power plants (PVPs) have been growing in size, and the installation time is very short. With the cost of photovoltaic (PV) panels dropping in recent years, it can be predicted that in the next 10 years the contribution of PVPs to the total number of renewable energy power plants will grow significantly. In this project, the National Renewable Energy Laboratory (NREL) developed a dynamic modeling of the modules to be used as building blocks to develop simulation models of single PV arrays, expanded to include Maximum Power Point Tracker (MPPT), expanded to include PV inverter, or expanded to cover an entire PVP. The focus of the investigation and complexity of the simulation determines the components that must be included in the simulation. The development of the PV inverter was covered in detail, including the control diagrams. Both the current-regulated voltage source inverter and the current-regulated current source inverter were developed in PSCAD. Various operations of the PV inverters were simulated under normal and abnormal conditions. Symmetrical and unsymmetrical faults were simulated, presented, and discussed. Both the three-phase analysis and the symmetrical component analysis were included to clarify the understanding of unsymmetrical faults. The dynamic model validation was based on the testing data provided by SCE. Testing was conducted at SCE with the focus on the grid interface behavior of the PV inverter under different faults and disturbances. The dynamic model validation covers both the symmetrical and unsymmetrical faults.

  14. DOE Shipment Activities: What We Accomplished and a Look Forward...

    Office of Environmental Management (EM)

    Accomplished and a Look Forward Presented by Stephen O'Connor, Director of Office of Packaging and Transportation. DOE Shipment Activities: What We Accomplished and a Look Forward...

  15. Enhancements to System for Tracking Radioactive Waste Shipments...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    features are new mapping tools, multi-mode, two-way communication that automatically switches between terrestrial and satellite, in-depth shipment reporting, event alerts and a...

  16. Naval Spent Fuel Rail Shipment Accident Exercise Objectives

    Office of Environmental Management (EM)

    NAVAL SPENT FUEL RAIL SHIPMENT ACCIDENT EXERCISE OBJECTIVES * Familiarize stakeholders with the Naval spent fuel ACCIDENT EXERCISE OBJECTIVES Familiarize stakeholders with the...

  17. DOE Shipment Activities: What We Accomplished and a Look Forward

    Office of Environmental Management (EM)

    wims.arc.fiu.eduwims 5 Plans for future shipments. . . * Waste Incidental to Reprocessing (WIR) Draft Evaluation for WVDP Melter * Depleted Uranium Oxide (DUO) from...

  18. PV technology differences and discrepancies in modelling between...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    sensitivity and limitations of present and alternative PV models The sensitivity and limitations of present and alternative PV models Steve Ransome - Independent PV Consultant,...

  19. Federal Tax Incentives for PV: Potential Implications for Program Design

    E-Print Network [OSTI]

    Wiser, Ryan; Bolinger, Mark

    2006-01-01

    Forthcoming. “EPAct 2005’s PV Tax Credits: What Are TheyAssumptions • Installed PV system costs exhibit economies ofFederal Tax Incentives for PV Potential Implications for

  20. User Shipments | Stanford Synchrotron Radiation Lightsource

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired SolarAbout /Two0 - 19PortalStatusUserUserHome ContactUserShipments

  1. Comparison of Pyranometers vs. PV Reference Cells for Evaluation of PV Array Performance

    SciTech Connect (OSTI)

    Dunn, L.; Gostein, M.; Emery, K.

    2012-09-01

    As the photovoltaics (PV) industry has grown, the need for accurately monitoring the solar resource of PV power plants has increased. Historically, the PV industry has relied on thermopile pyranometers for irradiance measurements, and a large body of historical irradiance data taken with pyranometers exists. However, interest in PV reference devices is increasing. In this paper, we discuss why PV reference devices are better suited for PV applications, and estimate the typical uncertainties in irradiance measurements made with both pyranometers and PV reference devices. We assert that the quantity of interest in monitoring a PV power plant is the equivalent irradiance under the IEC 60904-3 reference solar spectrum that would produce the same electrical response in the PV array as the incident solar radiation. For PV-plant monitoring applications, we find the uncertainties in irradiance measurements of this type to be on the order of +/-5% for thermopile pyranometers and +/-2.4% for PV reference devices.

  2. Webinar: Evaluating Roof Structures for Solar PV

    Office of Energy Efficiency and Renewable Energy (EERE)

    This webinar provides an overview of Connecticut's Structural Review Worksheet for Residential Rooftop Solar PV Systems. The webinar explains how the worksheet should be used and common concerns with wind and dead loads for rooftop solar PV.

  3. City of Healdsburg- PV Incentive Program

    Broader source: Energy.gov [DOE]

    Through the City of Healdsburg's PV Buy-down Program, residential and commercial customers are eligible for rebate on qualifying grid-connected PV systems. In keeping with SB1, (the California...

  4. PV prospects: thinPV prospects: thin--film cellsfilm cells Si cell costs

    E-Print Network [OSTI]

    Pulfrey, David L.

    1 PV prospects: thinPV prospects: thin--film cellsfilm cells LECTURE 8 · Si cell costs · optimizing://www.solarbuzz.com/Moduleprices.htm #12;6 Cost of PV modulesCost of PV modules The lowest retail price for a multicrystalline silicon

  5. PV Fact Sheets Argument B1Some people state that "The external costs of PV electricity

    E-Print Network [OSTI]

    PV Fact Sheets Argument B1Some people state that "The external costs of PV electricity is much shows the external costs for current PV systems at Southern and Central European locations in addition to other costs". For current PV installations in South-Europe the external costs are about 0.15 per k

  6. November 21, 2000 PV Lesson Plan 3 PV Array Generating Electricity

    E-Print Network [OSTI]

    Oregon, University of

    November 21, 2000 PV Lesson Plan 3 ­ PV Array Generating Electricity Prepared for the Oregon in Arrays: Solar Cells Generating Electricity Lesson Plan Content: In this lesson, students will learn about electricity. Objectives: Students will learn to use a tool called PV WATTS to calculate the output of PV

  7. PV Controls Utility-Scale Demonstration Project

    SciTech Connect (OSTI)

    O'Neill, Barbara; Gevorgian, Vahan

    2015-10-14

    This presentation provides a high-level overview of the utility-scale PV controls demonstration project.

  8. PV Odds & Ends by John Wiles

    E-Print Network [OSTI]

    Johnson, Eric E.

    PV Odds & Ends by John Wiles Sponsored by the U.S. Department of Energy There are two primary wiring methods for connecting PV modules together--using exposed single-conductor cables, and using conduits. Each dictates a different grounding method, but in either case, PV modules must always

  9. INTEGRATION OF PV IN DEMAND RESPONSE

    E-Print Network [OSTI]

    Perez, Richard R.

    INTEGRATION OF PV IN DEMAND RESPONSE PROGRAMS Prepared by Richard Perez et al. NREL subcontract the case that distributed PV generation deserves a substantial portion of the credit allotted to demand response programs. This is because PV generation acts as a catalyst to demand response, markedly enhancing

  10. Solar Resource and PV Systems Performance

    E-Print Network [OSTI]

    Solar Resource and PV Systems Performance at Selected Test Sites Prepared for the U.S. Department Subtask 11.1 Deliverables 2 and 4: Report on Solar Resource and PV Systems Performance at Selected Test agency thereof. #12;1 Solar Resource and PV Systems Performance at Selected Test Sites Contents 1

  11. PV-Modultechnik am ISFH Marc Kntges

    E-Print Network [OSTI]

    1 PV-Modultechnik am ISFH Marc Köntges Entwicklung Messen Prüfen Forschung 90°C #12;2 Aufbau eines. Schulte-Huxel, et al., IEEE J-PV, DOI: 10.1109/JPHOTOV.2012.2208096, 2012 Prozess bringt ganze in PV-Modullaminaten 90°C #12;Lichtsimulation Zellgap · Streulicht aus Zellzwischenraum wird teilweise

  12. Approaches To Integrating A HIgh Penertration Of Solar PV and CPV Onto The Electrical Grid

    E-Print Network [OSTI]

    Hill, Steven Craig

    2013-01-01

    improvements in cell efficiency Map of the continental US with filled contours indicated annual average direct normal solarsolar PV industry in conjunction with the continued improvement in efficiency of multijunction cellssolar cells . 123  Figure A.14 Efficiency histograms of last 5 generations of terrestrial cells   125  Figure A.15 Planned improvement 

  13. Grid Integrated Distributed PV (GridPV) Version 2.

    SciTech Connect (OSTI)

    Reno, Matthew J.; Coogan, Kyle

    2014-12-01

    This manual provides the documentation of the MATLAB toolbox of functions for using OpenDSS to simulate the impact of solar energy on the distribution system. The majority of the functio ns are useful for interfacing OpenDSS and MATLAB, and they are of generic use for commanding OpenDSS from MATLAB and retrieving information from simulations. A set of functions is also included for modeling PV plant output and setting up the PV plant in th e OpenDSS simulation. The toolbox contains functions for modeling the OpenDSS distribution feeder on satellite images with GPS coordinates. Finally, example simulations functions are included to show potential uses of the toolbox functions. Each function i n the toolbox is documented with the function use syntax, full description, function input list, function output list, example use, and example output.

  14. Estimating carbon emissions from less-than-truckload (LTL) shipments

    E-Print Network [OSTI]

    Veloso de Aguiar, Guilherme

    2014-01-01

    Less-than-truckload (LTL) is a $32-billion sector of the trucking industry that focuses on moving smaller shipments, typically with weights between 100 and 10,000 pounds, that do not require a full trailer to be moved. ...

  15. "TRU" Success: SRS Recovery Act Prepares to Complete Shipment...

    Broader source: Energy.gov (indexed) [DOE]

    Act Prepares to Complete Shipment of More Than 5,000 Cubic Meters of Nuclear Waste to WIPP More Documents & Publications TRUPACT-III Quick Facts EIS-0026-SA-06: Supplement...

  16. How sharp are PV measures?

    E-Print Network [OSTI]

    A. Jencova; S. Pulmannova

    2007-01-11

    Properties of sharp observables (normalized PV measures) in relation to smearing by a Markov kernel are studied. It is shown that for a sharp observable $P$ defined on a standard Borel space, and an arbitrary observable $M$, the following properties are equivalent: (a) the range of $P$ is contained in the range of $M$; (b) $P$ is a function of $M$; (c) $P$ is a smearing of $M$.

  17. PV output smoothing with energy storage.

    SciTech Connect (OSTI)

    Ellis, Abraham; Schoenwald, David Alan

    2012-03-01

    This report describes an algorithm, implemented in Matlab/Simulink, designed to reduce the variability of photovoltaic (PV) power output by using a battery. The purpose of the battery is to add power to the PV output (or subtract) to smooth out the high frequency components of the PV power that that occur during periods with transient cloud shadows on the PV array. The control system is challenged with the task of reducing short-term PV output variability while avoiding overworking the battery both in terms of capacity and ramp capability. The algorithm proposed by Sandia is purposely very simple to facilitate implementation in a real-time controller. The control structure has two additional inputs to which the battery can respond. For example, the battery could respond to PV variability, load variability or area control error (ACE) or a combination of the three.

  18. NRELs PV Tools on the Web: Open PV Project

    Energy Savers [EERE]

    NREL's PV Tools on the Web: The OpenPV Project NREL TAP Webinar Ted Quinby March 24, 2010 National Renewable Energy Laboratory Innovation for Our Energy Future Overview National...

  19. Performance of Mismatched PV Systems With Submodule Integrated Converters

    SciTech Connect (OSTI)

    Olalla, C; Deline, C; Maksimovic, D

    2014-01-01

    Mismatch power losses in photovoltaic (PV) systems can be reduced by the use of distributed power electronics at the module or submodule level. This paper presents an experimentally validated numerical model that can be used to predict power production with distributed maximum power point tracking (DMPPT) down to the cell level. The model allows the investigations of different DMPPT architectures, as well as the impact of conversion efficiencies and power constraints. Results are presented for annual simulations of three representative partial shading scenarios and two scenarios where mismatches are due to aging over a period of 25 years. It is shown that DMPPT solutions that are based on submodule integrated converters offer 6.9-11.1% improvements in annual energy yield relative to a baseline centralized MPPT scenario.

  20. Hybrid photovoltaic/thermal (PV/T) solar systems simulation with Simulink/Matlab

    SciTech Connect (OSTI)

    da Silva, R.M.; Fernandes, J.L.M.

    2010-12-15

    The purpose of this work consists in thermodynamic modeling of hybrid photovoltaic-thermal (PV/T) solar systems, pursuing a modular strategy approach provided by Simulink/Matlab. PV/T solar systems are a recently emerging solar technology that allows for the simultaneous conversion of solar energy into both electricity and heat. This type of technology present some interesting advantages over the conventional ''side-by-side'' thermal and PV solar systems, such as higher combined electrical/thermal energy outputs per unit area, and a more uniform and aesthetical pleasant roof area. Despite the fact that early research on PV/T systems can be traced back to the seventies, only recently it has gained a renewed impetus. In this work, parametric studies and annual transient simulations of PV/T systems are undertaken in Simulink/Matlab. The obtained results show an average annual solar fraction of 67%, and a global overall efficiency of 24% (i.e. 15% thermal and 9% electrical), for a typical four-person single-family residence in Lisbon, with p-Si cells, and a collector area of 6 m{sup 2}. A sensitivity analysis performed on the PV/T collector suggests that the most important variable that should be addressed to improve thermal performance is the photovoltaic (PV) module emittance. Based on those results, some additional improvements are proposed, such as the use of vacuum, or a noble gas at low-pressure, to allow for the removal of PV cells encapsulation without air oxidation and degradation, and thus reducing the PV module emittance. Preliminary results show that this option allows for an 8% increase on optical thermal efficiency, and a substantial reduction of thermal losses, suggesting the possibility of working at higher fluid temperatures. The higher working temperatures negative effect in electrical efficiency was negligible, due to compensation by improved optical properties. The simulation results are compared with experimental data obtained from other authors and perform reasonably well. The Simulink modeling platform has been mainly used worldwide on simulation of control systems, digital signal processing and electric circuits, but there are very few examples of application to solar energy systems modeling. This work uses the modular environment of Simulink/Matlab to model individual PV/T system components, and to assemble the entire installation layout. The results show that the modular approach strategy provided by Matlab/Simulink environment is applicable to solar systems modeling, providing good code scalability, faster developing time, and simpler integration with external computational tools, when compared with traditional imperative-oriented programming languages. (author)

  1. National solar technology roadmap: Concentrator PV

    SciTech Connect (OSTI)

    Friedman, Dan

    2007-06-01

    This roadmap addresses high-concentration (>10x) photovoltaic (PV) systems, incorporating high-efficiency III-V or silicon cells, trackers, and reflective or refractive optics.

  2. Integrating Solar PV in Utility System Operations

    E-Print Network [OSTI]

    Mills, A.

    2014-01-01

    costs with constant nuclear in the high-PV scenario partly because of the large decrease in curtailment of renewable energy,

  3. Integrating Solar PV in Utility System Operations

    E-Print Network [OSTI]

    Mills, A.

    2014-01-01

    2007a, “Evaluating the Limits of Solar Photovoltaics (PV) infor Short-Term Variability of Solar Power. Lawrence Berkeleyand Medium Term Operational Solar Radiation Forecasts in the

  4. Updating Interconnection Screens for PV System Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Abraham Ellis, Roger Hill Sandia National Laboratories Tom Key, Kristen Nicole, Jeff Smith Electric Power Research Institute Updating Interconnection Screens for PV System...

  5. CPS Energy- Solar PV Rebate Program

    Broader source: Energy.gov [DOE]

    CPS Energy, San Antonio's municipal utility, offers rebates to customers who install solar photovoltaic (PV) systems on their homes, schools, or businesses. There are four rebate "tiers" available...

  6. Ensuring Quality of PV Modules: Preprint

    SciTech Connect (OSTI)

    Kurtz, S.; Wohlgemuth, J.; Hacke, P.; Kempe, M.; Sample, T.; Yamamichi, M.; Kondo, M.; Doi, T.; Otani, K.; Amano, J.

    2011-07-01

    Photovoltaic (PV) customers need to have confidence in the PV modules they purchase. Currently, no test can quantify a module's lifetime with confidence, but stress tests are routinely used to differentiate PV product designs. We suggest that the industry would be strengthened by using the wisdom of the community to develop a single set of tests that will help customers quantify confidence in PV products. This paper evaluates the need for quality assurance (QA) standards and suggests a path for creating these. Two types of standards are needed: 1) QA of the module design and 2) QA of the manufacturing process.

  7. PV AND GRID RELIABILITY: AVAILABILITY OF PV POWER DURING CAPACITY SHORTFALLS

    E-Print Network [OSTI]

    Perez, Richard R.

    PV AND GRID RELIABILITY: AVAILABILITY OF PV POWER DURING CAPACITY SHORTFALLS Richard Perez events caused by high, localized demand and inability for the grid operators to deliver local power at photovoltaic (PV) power availability during major summer 1999-2000 power outages in the United States. We

  8. PV Systems | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX ECoop Inc Jump to:Newberg,Energy LLC Jump to:3 of Mason County Jump to:EiwaSwedenPV

  9. Kailun PV | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LISTStar2-0057-EAInvervar Hydro JumpHuari Silicon MaterialJuncoKSKKailun PV Jump to:

  10. NREL: Photovoltaics Research - PV News

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformationJessework usesof EnergyY-12Working withPhoto of1855JohnScienceNancyNewsPV

  11. Sandia Energy - PV Program Disclaimer

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II)Geothermal Energy &WaterNew CREWOnline Abstracts andPV ModelingProgram

  12. Berkeley Program Offers New Option for Financing Residential PV Systems

    E-Print Network [OSTI]

    Bolinger, Mark A

    2009-01-01

    financing does not reduce the high up-front cost of PV, byto PV owners, including long- term, fixed-cost, attractivecost over some portion of the system’s life, financing can certainly make PV

  13. Federal Tax Incentives for PV: Potential Implications for Program Design

    E-Print Network [OSTI]

    Wiser, Ryan; Bolinger, Mark

    2006-01-01

    encourage demand for PV and value/cost/tax-efficiency of PBIAssumptions • Installed PV system costs exhibit economies ofPV above historical (pre-EPAct) levels • Recent increase in module costs (

  14. Summary Review of Advanced Inverter Technologies for Residential PV Systems

    E-Print Network [OSTI]

    Summary Review of Advanced Inverter Technologies for Residential PV Systems This report summarizes current and emerging standards for residential PV systems and identifies the status of emerging inverter................................................................................................ 7 3. Grid-Connected PV inverters available in US

  15. Solar PV Permitting and Safety Training Webinar

    Broader source: Energy.gov [DOE]

    This webinar provides training on two permitting resources for municipal inspectors; a prescriptive process for building inspectors and a guidance document for permitting for PV for electrical inspectors. The webinar also runs through a number of key code articles in Massachusetts 2014 electrical code and examines a variety of safety hazards commonly found during or after solar PV installations.

  16. Draft Transcript on Municipal PV Systems

    Office of Energy Efficiency and Renewable Energy (EERE)

    Webinar on navigating the legal, tax, and finance issues associated with the installation of Municipal PV Systems. The following agenda was developed based on Pat Boylston's experience assisting municipalities with their PV projects and the requests for information that the Solar America City technical team leads have received from many of the 25 Solar America Cities since the April 2008 meeting in Tucson.

  17. Pipe overpack container for trasuranic waste storage and shipment

    DOE Patents [OSTI]

    Geinitz, Richard R. (Arvada, CO); Thorp, Donald T. (Broomfield, CO); Rivera, Michael A. (Boulder, CO)

    1999-01-01

    A Pipe Overpack Container for transuranic waste storage and shipment. The system consists of a vented pipe component which is positioned in a vented, insulated 55 gallon steel drum. Both the vented pipe component and the insulated drum are capable of being secured to prevent the contents from leaving the vessel. The vented pipe component is constructed of 1/4 inch stainless steel to provide radiation shielding. Thus, allowing shipment having high Americium-241 content. Several Pipe Overpack Containers are then positioned in a type B, Nuclear Regulatory Commission (NRC) approved, container. In the current embodiment, a TRUPACT-II container was employed and a maximum of fourteen Pipe Overpack Containers were placed in the TRUPACT-II. The combination received NRC approval for the shipment and storage of transuranic waste.

  18. Smart-Grid Ready PV Inverter with Utility Communication

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    standards, operations center visibility and management, and optimized coordination of smart PV inverters with existing distribution control devices. Smart-Grid Ready PV Inverter...

  19. An Analysis of Residential PV System Price Differences between...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    PV System Price Differences between the United States and Germany Residential photovoltaic (PV) systems were twice as expensive in the United States as in Germany (median of...

  20. Full Steam Ahead for PV in US Homes?

    E-Print Network [OSTI]

    Bolinger, Mark A

    2009-01-01

    state, local, and utility rebate programs targeting solar –implications for PV rebate program administrators, PV systemReduce the Size of the Rebates They Provide Without

  1. SunShot Presentation PV Module Reliabity Workshop Opening Session...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Presentation PV Module Reliabity Workshop Opening Session SunShot Presentation PV Module Reliabity Workshop Opening Session This PowerPoint slide deck was originally presented at...

  2. Low Cost High Concentration PV Systems for Utility Power Generation...

    Broader source: Energy.gov (indexed) [DOE]

    Residential and Utility Solar Power Generating Systems SunPower,Low Cost Thin Film Building-Integrated PV Systems Low Cost High Concentration PV Systems for Utility Power...

  3. Kauai, Hawaii: Solar Resource Analysis and High-Penetration PV...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Kauai, Hawaii: Solar Resource Analysis and High-Penetration PV Potential Kauai, Hawaii: Solar Resource Analysis and High-Penetration PV Potential This study looks at the technical...

  4. Department of Veterans Affairs, FONSI - Rooftop solar PV power...

    Energy Savers [EERE]

    Rooftop solar PV power at Calverton National Cemetery Department of Veterans Affairs, FONSI - Rooftop solar PV power at Calverton National Cemetery An Environmental Assessment (EA)...

  5. PV Performance and Reliability Validation Capabilities at Sandia...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    PV Performance and Reliability Validation Capabilities at Sandia National Laboratories PV Performance and Reliability Validation Capabilities at Sandia National Laboratories This...

  6. Air Shipment of Spent Nuclear Fuel from Romania to Russia

    SciTech Connect (OSTI)

    Igor Bolshinsky; Ken Allen; Lucian Biro; Alexander Buchelnikov

    2010-10-01

    Romania successfully completed the world’s first air shipment of spent nuclear fuel transported in Type B(U) casks under existing international laws and without shipment license special exceptions when the last Romanian highly enriched uranium (HEU) spent nuclear fuel was transported to the Russian Federation in June 2009. This air shipment required the design, fabrication, and licensing of special 20 foot freight containers and cask tiedown supports to transport the eighteen TUK 19 shipping casks on a Russian commercial cargo aircraft. The new equipment was certified for transport by road, rail, water, and air to provide multi modal transport capabilities for shipping research reactor spent fuel. The equipment design, safety analyses, and fabrication were performed in the Russian Federation and transport licenses were issued by both the Russian and Romanian regulatory authorities. The spent fuel was transported by truck from the VVR S research reactor to the Bucharest airport, flown by commercial cargo aircraft to the airport at Yekaterinburg, Russia, and then transported by truck to the final destination in a secure nuclear facility at Chelyabinsk, Russia. This shipment of 23.7 kg of HEU was coordinated by the Russian Research Reactor Fuel Return Program (RRRFR), as part of the U.S. Department of Energy Global Threat Reduction Initiative (GTRI), in close cooperation with the Rosatom State Atomic Energy Corporation and the International Atomic Energy Agency, and was managed in Romania by the National Commission for Nuclear Activities Control (CNCAN). This paper describes the planning, shipment preparations, equipment design, and license approvals that resulted in the safe and secure air shipment of this spent nuclear fuel.

  7. The Impact of Retail Rate Structures on the Economics ofCustomer-Sited PV: A Study of Commercial Installations inCalifornia

    SciTech Connect (OSTI)

    Wiser, Ryan; Mills, Andrew; Barbose, Galen; Golove, William

    2007-06-01

    We analyze the impact of retail rate design on the economics of grid-connected commercial photovoltaic (PV) systems in California. The analysis is based on 15-minute interval building load and PV production data for 24 commercial PV installations in California, spanning a diverse set of building load shapes and geographic locations. We derive the annual bill savings per kWh generated for each PV system, under each of 21 distinct retail rates currently offered by the five largest utilities in California. We identify and explain variation in the value of bill savings attributable to differences in the structure of demand and energy charges across rates, as well as variation attributable to other factors, such as the size of the PV system relative to building load, the specific shape of the PV production profile, and the customer load profile. We also identify the optimal rate for each customer, among those rates offered as alternatives to one another, and show how the decision is driven in large measure by the size of the PV system relative to building load. The findings reported here may be of value to regulators and utilities responsible for designing retail rates, as well as to customers and PV retailers who have a need to estimate the prospective bill savings of PV systems.

  8. THE IMPACT OF CITY-LEVEL PERMITTING PROCESSES ON RESIDENTIAL PV INSTALLATION PRICES AND DEVELOPMENT TIMES

    E-Print Network [OSTI]

    Dong, Changgui

    2014-01-01

    The installed price of photovoltaic (PV) systems hasprice and development time of residential photovoltaic (PV)

  9. Terawatt Challenge for Thin-Film PV

    SciTech Connect (OSTI)

    Zweibel, K.

    2005-08-01

    The evolution of PV into one of the world's largest industries is not going to happen without major unforeseen problems. However, this study attempts to address the obvious ones, so that we can put aside the mythology of PV (for example, that it is only ''boutique power'' or that one must pave the world with it to be useful) and get on with changing the world's energy infrastructure. With the years of rapid market growth now under way in PV, the author is sure this will not be the last effort to understand the real potential and pitfalls of meeting the Challenge.

  10. (Eigen Phoneme Space (Phoneme Vector : PV)

    E-Print Network [OSTI]

    Takiguchi, Tetsuya

    ) (Phoneme Vector : PV) Fig. 1 (EPS) /a/ /i/ · · · PCA (EPS) 2.2 PCA PCA i Si Si = 1 N N t=1 (xi t - ¯xi )(xi (6) #12;Fig. 2 Phoneme Vector (PV) extraction (6) yt (Q×M) yt PCA y t y t = V T (yt - ¯y) (7) V = [1 , 2 , · · · , R ] R Fig. 2 3 3.1 DCT PCA MFCC PCA PV 32 16 32 (Q) 5 21 2 ATR A-SET 2,620 54 HMM 1

  11. Composite Variable Formulations for Express Shipment Service Network Design

    E-Print Network [OSTI]

    Gendron, Bernard

    · Cynthia Barnhart · Keith A. Ware Department of Management, United States Air Force Academy, Colorado, Kentucky 40223 In this paper we describe a new approach to solving the express shipment service net- work design problem. Conventional polyhedral methods for network design and network loading problems do

  12. Benchmarking Soft Costs for PV Systems in the United States (Presentation)

    SciTech Connect (OSTI)

    Ardani, K.

    2012-06-01

    This paper presents results from the first U.S. based data collection effort to quantify non-hardware, business process costs for PV systems at the residential and commercial scales, using a bottom-up approach. Annual expenditure and labor hour productivity data are analyzed to benchmark business process costs in the specific areas of: (1) customer acquisition; (2) permitting, inspection, and interconnection; (3) labor costs of third party financing; and (4) installation labor.

  13. Measured Performance of California Buydown Program Residential PV Systems

    E-Print Network [OSTI]

    Measured Performance of California Buydown Program Residential PV Systems Kurt Scheuermann a proposal to monitor in-field performance of photovoltaic (PV) and hybrid PV/small wind systems funded collected from fourteen PV systems from mid-February through September, 2000. In December 2000 and January

  14. Solar Works! In Seattle: Introduction to Solar Electric (PV)

    Office of Energy Efficiency and Renewable Energy (EERE)

    Presentation slides from residential PV workshop. Also covers general solar resource assessment, siting and financial incentives.

  15. Energy 101: Solar PV | Department of Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    on www.youtube.com, or enable JavaScript if it is disabled in your browser. Description Solar photovoltaic (PV) systems can generate clean, cost-effective power anywhere the sun...

  16. Sandia Energy - Evaluating Rooftop Strength for PV

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    for PVcwdd2015-09-30T16:55:16+00:00 Confirming the Strength of Residential Roof Structures for Solar Installations Test Setup Photo Test Setup The solar photovoltaic (PV)...

  17. City of Lompoc Utilities- PV Rebate Program

    Broader source: Energy.gov [DOE]

    City of Lompoc Utilities provides rebates to its electric customers who purchase and install photovoltaic (PV) systems. The rebate is $1.00 per watt-AC. The incentive amount may not exceed 50% the...

  18. Distributed PV Permitting and Inspection Processes

    Broader source: Energy.gov [DOE]

    This presentation summarizes case studies of the time and cost involved in the distributed PV permitting and inspection process in three Solar America Cities, Austin, Portland, and Salt Lake City.

  19. PV Module Reliability Research (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-06-01

    This National Center for Photovoltaics sheet describes the capabilities of its PV module reliability research. The scope and core competencies and capabilities are discussed and recent publications are listed.

  20. PV1 model verification and validation

    E-Print Network [OSTI]

    Fuller, Frank H.

    1981-01-01

    The purpose of this document is 1) to describe, in detail, the theoretic foundation on which PV1 is based, 2) indicate the manner in which its theoretical foundation has been translated into a practical, useful tool for ...

  1. Sandia Energy - PV Reliability & Performance Model

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Model PV Reliability & Performance ModelTara Camacho-Lopez2015-06-01T20:13:00+00:00 This Web Demo model is a simplified "player" version of the Photovoltaic Reliability Performance...

  2. Solar Energy International Solar PV 101 Training

    Broader source: Energy.gov [DOE]

    Solar Energy International is offering a five-day training that provides an overview of the three basic PV system applications, primarily focusing on grid-direct systems. The goal of the course is...

  3. Austin Energy- Commercial Solar PV Incentive Program

    Broader source: Energy.gov [DOE]

    In order to qualify for this program, PV modules must be new and be listed on the California Energy Commission's Go Solar web site. In addition, all solar panels must have a 20-year manufacturer ...

  4. Merced Irrigation District- PV Buydown Program

    Broader source: Energy.gov [DOE]

    Merced Irrigation District (MID) offers its residential, commercial and non-profit customers a rebate for installing solar electric photovoltaic (PV) systems on their homes and offices. For 2015,...

  5. Plumas-Sierra REC- PV Rebate Program

    Broader source: Energy.gov [DOE]

    Plumas-Sierra REC offers an incentive for its customers to install photovoltaic (PV) systems on homes and businesses. Rebates are available for qualifying systems between one kilowatt (kW) and 25...

  6. SMUD- PV Residential Retrofit Buy-Down

    Broader source: Energy.gov [DOE]

    The incentive can be paid directly to the customer or the installer. PV equipment listed on the CEC Approved Equipment list is eligible for incentives: http://www.gosolarcalifornia.org/equipment...

  7. PV System Energy Evaluation Method (Presentation)

    SciTech Connect (OSTI)

    Kurtz, S.

    2014-01-01

    This presentation describes a comparison of the "predicted" energy (based on historical weather data) with the "expected" energy (based on the measured weather data) to determine whether a PV system is performing as modeled in order to verify the accuracy of a model. A key factor in defining this energy test is determining the test boundary so that weather variations are not inadvertently included in what is considered to be PV system performance.

  8. Power losses in PV arrays due to variations in the I-V characteristics of PV modules

    E-Print Network [OSTI]

    Heinemann, Detlev

    Power losses in PV arrays due to variations in the I-V characteristics of PV modules Wolfgang Damm-V characteristics of the 36 individual modules of a PV generator at the University of Oldenburg were measured the basis for the calculations of the mismatch losses due to series and parallel connection of PV modules

  9. Updating Technical Screens for PV Interconnection: Preprint

    SciTech Connect (OSTI)

    Coddington, M.; Ellis, A.; Lynn, K.; Razon, A.; Key, T.; Kroposki, B.; Mather, B.; Hill, R.; Nicole, K.; Smith, J.

    2012-08-01

    Solar photovoltaics (PV) is the dominant type of distributed generation (DG) technology interconnected to electric distribution systems in the United States, and deployment of PV systems continues to increase rapidly. Considering the rapid growth and widespread deployment of PV systems in United States electric distribution grids, it is important that interconnection procedures be as streamlined as possible to avoid unnecessary interconnection studies, costs, and delays. Because many PV interconnection applications involve high penetration scenarios, the process needs to allow for a sufficiently rigorous technical evaluation to identify and address possible system impacts. Existing interconnection procedures are designed to balance the need for efficiency and technical rigor for all DG. However, there is an implicit expectation that those procedures will be updated over time in order to remain relevant with respect to evolving standards, technology, and practical experience. Modifications to interconnection screens and procedures must focus on maintaining or improving safety and reliability, as well as accurately allocating costs and improving expediency of the interconnection process. This paper evaluates the origins and usefulness of the capacity penetration screen, offers potential short-term solutions which could effectively allow fast-track interconnection to many PV system applications, and considers longer-term solutions for increasing PV deployment levels in a safe and reliable manner while reducing or eliminating the emphasis on the penetration screen.

  10. Performance Modeling of an Air-Based Photovoltaic/Thermal (PV/T) Collector

    SciTech Connect (OSTI)

    Casey, R. D.; Brandemuehl, M. J.; Merrigan, T.; Burch, J.

    2010-01-01

    This paper studies a collector design that utilizes unglazed photovoltaic/thermal (PV/T) collectors preheating air for glazed air heating modules. The performance modeling of these collectors is examined both individually and in series. For each collector type, a dynamic, finite difference, first-law model has been created using literature correlations for friction. The models were compared to performance data, calibrating the models by scaling of friction terms for best fit. The calibrated models generally agree well with the experimental data; even during sudden changes to ambient conditions. The root mean square error between the unglazed PV/T model and experiment results for the useful thermal energy gain and the outlet air temperature are 7.12 W/m{sup 2} and 1.07 C, respectively. The annual source energy performance of the building-integrated PV/T (BIPV/T) array is then simulated for residential applications in seven climate zones of the United States of America. The performance of the BIPV/T array is characterized by the amount of net electrical energy and useful thermal energy produced. The useful thermal energy is defined as the amount of energy offset by the BIPV/T system for water heating and space conditioning. A BIPV/T system composed 87.5% of PV modules, and 12.5% of glazed air heating modules, offsets the same amount of source energy as a roof-mounted PV system of the same area. This array composition increases the thermal energy gain by 47% over a BIPV/T array composed solely of PV modules.

  11. PVGIS approach for assessing the performances of the first PV grid-connected power plant in Morocco

    E-Print Network [OSTI]

    Barhdadi, Abdelfettah

    2012-01-01

    In this paper, we apply the PVGIS method for estimating the performance of the first grid-connected PV micro-power plant in Morocco. PVGIS approach provides analysis and assessment of in-site solar energy resources and predicts with good accuracy the potential of PV systems in term of electricity production. We find that annual total power generation of the micro-power is slightly higher than that initially expected at the installation stage and actually measured. The yearly predicted and measured power production values agree to about 2 %. However, individual monthly production can have larger discrepancy.

  12. Photovoltaic (PV) Pricing Trends: Historical, Recent, and Near-Term Projections

    E-Print Network [OSTI]

    Feldman, David

    2014-01-01

    Utility-Scale Photovoltaic (PV) System Prices in the Unitedphotovoltaic (PV) systems has soared in recent years, driven by declining PV prices

  13. Do PV Systems Increase Residential Selling Prices If So, How Can Practitioners Estimate This Increase?

    E-Print Network [OSTI]

    Hoen, Ben

    2013-01-01

    underlying net installation costs for PV systems between newfrom electricity cost savings after PV system installationannual electricity cost savings associated with PV they are

  14. Holdover inoculum of Pseudomonas syringae pv. alisalensis from broccoli raab causes disease in subsequent plantings

    E-Print Network [OSTI]

    Cintas, N A; Koike, S T; Bunch, R A; Bull, C T

    2006-01-01

    by Pseudomonas syringae pv. alisalensis in California. Plantof Pseudo- monas syringae pv. alisalensis. (Abstr. ) Phyto-2004. Pseudomonas syringae pv. alisalensis and Pseudomonas

  15. Analyzing and simulating the variability of solar irradiance and solar PV powerplants

    E-Print Network [OSTI]

    Lave, Matthew S.

    2012-01-01

    Analysis of Distributed PV, American Solar Energy Society,Simulating the Reduction in PV Powerplant Variability due to8] T. Hoff, R. Perez, Modeling PV Fleet Output Variability,

  16. An efficient method for visualization and growth of fluorescent Xanthomonas oryzae pv. oryzae in planta.

    E-Print Network [OSTI]

    Han, Sang-Wook; Park, Chang-Jin; Lee, Sang-Won; Ronald, Pamela C

    2008-01-01

    Background Xanthomonas oryzae pv. oryzae, a yellow-pigmentedsativa L. ) plants. X. oryzae pv. oryzae infection can causetropical Asia [1]. X. oryzae pv. oryzae infects rice leaves

  17. A Wavelet-Based Variability Model (WVM) for Solar PV Power Plants

    E-Print Network [OSTI]

    Lave, Matthew; Kleissl, Jan; Stein, Joshua S

    2013-01-01

    Power characteristics of PV ensembles: experiences from theproduction of 100 grid connected PV systems distributed overHoff and R. Perez, "Modeling PV Fleet Output Variability,"

  18. Designing PV Incentive Programs to Promote System Performance: A Review of Current Practice

    E-Print Network [OSTI]

    Barbose, Galen; Wiser, Ryan; Bolinger, Mark

    2006-01-01

    Dan. 2006. Best Practices in PV Rebate Programs: Helpingprogram staff. Designing PV Incentive Programs to PromoteGroup), Mike Taylor Designing PV Incentive Programs to

  19. Designing PV Incentive Programs to Promote Performance: A Review of Current Practice

    E-Print Network [OSTI]

    Barbose, Galen; Wiser, Ryan; Bolinger, Mark

    2007-01-01

    DESIGNING PV INCENTIVE PROGRAMS TO PROMOTE SYSTEMcustomer-sited photovoltaic (PV) systems, provided throughface to ensuring that their PV systems perform well, and the

  20. Photovoltaic (PV) Pricing Trends: Historical, Recent, and Near-Term Projections

    E-Print Network [OSTI]

    Feldman, David

    2014-01-01

    all. Super monocrystalline PV modules are currently the mostBloomberg New Energy Finance. PV Market Outlook, Q1 2012 (Solar Photovoltaic Industry: Solar PV industry outlook and

  1. Quantitative Measurements of Xanthomonas Oryzae pv. Oryzae Distribution in Rice Using Fluorescent-Labeling

    E-Print Network [OSTI]

    Nozue, Kazunari; Park, Chang-Jin; Ronald, Pamela C

    2011-01-01

    of Xanthomonas Oryzae pv. Oryzae Distribution in Rice Usingstrains of Xanthomonas oryzae pv. oryzae (Xoo), the casualKeywords Xanthomonas oryzae pv. oryzae, GFP, Oryza sativa .

  2. A Wavelet-Based Variability Model (WVM) for Solar PV Power Plants

    E-Print Network [OSTI]

    Lave, Matthew; Kleissl, Jan; Stein, Joshua S

    2013-01-01

    Model (WVM) for Solar PV Power Plants Matthew Lave, Jansimulating solar photovoltaic (PV) power plant output giventhe power output of a solar photovoltaic (PV) plant was

  3. Sandia Energy - PV Arc-Fault and Ground Fault Detection and Mitigation...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Program Home Stationary Power Energy Conversion Efficiency Solar Energy Photovoltaics PV Systems Reliability PV Arc-Fault and Ground Fault Detection and Mitigation Program PV...

  4. DOE High Performance Concentrator PV Project

    SciTech Connect (OSTI)

    McConnell, R.; Symko-Davies, M.

    2005-08-01

    Much in demand are next-generation photovoltaic (PV) technologies that can be used economically to make a large-scale impact on world electricity production. The U.S. Department of Energy (DOE) initiated the High-Performance Photovoltaic (HiPerf PV) Project to substantially increase the viability of PV for cost-competitive applications so that PV can contribute significantly to both our energy supply and environment. To accomplish such results, the National Center for Photovoltaics (NCPV) directs in-house and subcontracted research in high-performance polycrystalline thin-film and multijunction concentrator devices with the goal of enabling progress of high-efficiency technologies toward commercial-prototype products. We will describe the details of the subcontractor and in-house progress in exploring and accelerating pathways of III-V multijunction concentrator solar cells and systems toward their long-term goals. By 2020, we anticipate that this project will have demonstrated 33% system efficiency and a system price of $1.00/Wp for concentrator PV systems using III-V multijunction solar cells with efficiencies over 41%.

  5. AIR SHIPMENT OF SPENT NUCLEAR FUEL FROM THE BUDAPEST RESEARCH REACTOR

    SciTech Connect (OSTI)

    Dewes, J.

    2014-02-24

    The shipment of spent nuclear fuel is usually done by a combination of rail, road or sea, as the high activity of the SNF needs heavy shielding. Air shipment has advantages, e.g. it is much faster than any other shipment and therefore minimizes the transit time as well as attention of the public. Up to now only very few and very special SNF shipments were done by air, as the available container (TUK6) had a very limited capacity. Recently Sosny developed a Type C overpack, the TUK-145/C, compliant with IAEA Standard TS-R-1 for the VPVR/M type Skoda container. The TUK-145/C was first used in Vietnam in July 2013 for a single cask. In October and November 2013 a total of six casks were successfully shipped from Hungary in three air shipments using the TUK-145/C. The present paper describes the details of these shipments and formulates the lessons learned.

  6. Packaging and Transportation for Offsite Shipment of Materials of National Security Interests

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2015-04-20

    The Order establishes requirements and responsibilities for ensuring the safety of packaging and transportation for offsite shipments of Materials of National Security Interest.

  7. Large-Scale PV Integration Study

    SciTech Connect (OSTI)

    Lu, Shuai; Etingov, Pavel V.; Diao, Ruisheng; Ma, Jian; Samaan, Nader A.; Makarov, Yuri V.; Guo, Xinxin; Hafen, Ryan P.; Jin, Chunlian; Kirkham, Harold; Shlatz, Eugene; Frantzis, Lisa; McClive, Timothy; Karlson, Gregory; Acharya, Dhruv; Ellis, Abraham; Stein, Joshua; Hansen, Clifford; Chadliev, Vladimir; Smart, Michael; Salgo, Richard; Sorensen, Rahn; Allen, Barbara; Idelchik, Boris

    2011-07-29

    This research effort evaluates the impact of large-scale photovoltaic (PV) and distributed generation (DG) output on NV Energy’s electric grid system in southern Nevada. It analyzes the ability of NV Energy’s generation to accommodate increasing amounts of utility-scale PV and DG, and the resulting cost of integrating variable renewable resources. The study was jointly funded by the United States Department of Energy and NV Energy, and conducted by a project team comprised of industry experts and research scientists from Navigant Consulting Inc., Sandia National Laboratories, Pacific Northwest National Laboratory and NV Energy.

  8. Updating Interconnection Screens for PV System Integration

    SciTech Connect (OSTI)

    Coddington, M.; Mather, B.; Kroposki, B.; Lynn, K.; Razon, A.; Ellis, A.; Hill, R.; Key, T.; Nicole, K.; Smith, J.

    2012-02-01

    This white paper evaluates the origins and usefulness of the capacity penetration screen, offer short-term solutions which could effectively allow fast-track interconnection to many PV system applications, and considers longer-term solutions for increasing PV deployment levels in a safe and reliable manner while reducing or eliminating the emphasis on the penetration screen. Short-term and longer-term alternatives approaches are offered as examples; however, specific modifications to screening procedures should be discussed with stakeholders and must ultimately be adopted by state and federal regulatory bodies.

  9. International PV QA Task Force's Proposed Comparative Rating System for PV Modules: Preprint

    SciTech Connect (OSTI)

    Wohlgemuth, J.; Kurtz, S.

    2014-10-01

    The International PV Quality Assurance Task Force is developing a rating system that provides comparative information about the relative durability of PV modules. Development of accelerated stress tests that can provide such comparative information is seen as a major step toward being able to predict PV module service life. This paper will provide details of the ongoing effort to determine the format of such an overall module rating system. The latest proposal is based on using three distinct climate zones as defined in IEC 60721-2-1 for two different mounting systems. Specific stresses beyond those used in the qualification tests are being developed for each of the selected climate zones.

  10. U.S. Aims for Zero-Energy: Support for PV on New Homes

    E-Print Network [OSTI]

    Barbose, Galen; Wiser, Ryan; Bolinger, Mark

    2006-01-01

    solar photovoltaic (PV) adoption, new homes have a number ofenergy funds for encouraging PV adoption in new, market-ratePV as an option is that PV adoption is contingent on each

  11. Breakout Session: A Look Ahead: PV Manufacturing in 10 Years

    Broader source: Energy.gov [DOE]

    The global PV manufacturing landscape has undergone significant changes in the past decade, from geographic and economic changes in the supply chain to a significant increase in PV module...

  12. Energy Efficiency First, Zero Energy Ready Homes, and Solar PV...

    Office of Environmental Management (EM)

    Energy Efficiency First, Zero Energy Ready Homes, and Solar PV Updates Energy Efficiency First, Zero Energy Ready Homes, and Solar PV Updates April 29, 2015 11:00AM to 12:30PM MDT...

  13. Photovoltaic (PV) Pricing Trends: Historical, Recent, and Near-Term

    E-Print Network [OSTI]

    Photovoltaic (PV) Pricing Trends: Historical, Recent, and Near-Term Projections November 2012 #12;Photovoltaic (PV) Pricing Trends: Historical, Recent, and Near-Term Projections David Feldman1 , Galen Barbose2........................................................................................................................................... 1 2. Historical and Recent Reported Prices

  14. Berkeley Program Offers New Option for Financing Residential PV Systems

    E-Print Network [OSTI]

    Bolinger, Mark A

    2009-01-01

    Clean Energy States Alliance, titled “Property Tax Assessments as a Finance Vehicle for Residential PV Installations: Opportunities and Potential

  15. The Economic Value of PV and Net Metering to Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim

    2010-01-01

    distributed photovoltaics (PV) adoption. Though specificadoption. In the long-run, however, this variation in the value of PV

  16. Personeelsvereniging Technische Universiteit Eindhoven DOE MEE met de PV !!

    E-Print Network [OSTI]

    Franssen, Michael

    Personeelsvereniging Technische Universiteit Eindhoven DOE MEE met de PV !! Eindhoven 12 maart 2012 Het bestuur van de PV is dringend op zoek naar verjonging en nieuwe invulling van de volgende rollen Aanspreekpunt voor activiteiten Exacte invulling van de functie, mogelijk in duo, in overleg met het PV bestuur

  17. Informations et rservations : ce.pv-holidays.com

    E-Print Network [OSTI]

    Arleo, Angelo

    Informations et réservations : ce.pv-holidays.com * Offre valable pour tout séjour de 7 nuits détails sur ce.pv-holidays.com. Offre valable sur l'hébergement seul (hors frais de dossier, prestations cumulable avec votre remise partenaire, toute offre promotionnelle ou réductions. PV-CPDistribution, Société

  18. Results from measurements on the PV-VENT systems

    E-Print Network [OSTI]

    Results from measurements on the PV-VENT systems at Lundebjerg Solar Energy Centre Denmark Danish from measurements on the PV-VENT systems at Lundebjerg Søren Østergaard Jensen Solar Energy Centre with (Jensen, 2000a) Solar Energy Centre Denmark's (Danish Technological Institute) measuring work in the PV

  19. Dynamic Interactions of PV units in Low Volatge Distribution Systems

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Dynamic Interactions of PV units in Low Volatge Distribution Systems M. J. Hossain, J. Lu Griffith. Abstract--Photovoltaic (PV) units along with other distributed energy resources (DERs) are located close, robust control, stability. I. Introduction The integration level of PV units in low and medium voltage

  20. A GUIDE TO PHOTOVOLTAIC (PV) SYSTEM DESIGN AND INSTALLATION

    E-Print Network [OSTI]

    CALIFORNIA ENERGY COMMISSION A GUIDE TO PHOTOVOLTAIC (PV) SYSTEM DESIGN AND INSTALLATION JUNE 2001 500-01-020 CONSULTANTREPORT Gray Davis, Governor #12;PV Installation Guide June 2001 Page 1 A GUIDE TO PHOTOVOLTAIC (PV) SYSTEM DESIGN AND INSTALLATION Prepared for: California Energy Commission Energy Technology

  1. Experience Curves and Solar PV Fred Heutte, Senior Policy Associate

    E-Print Network [OSTI]

    resources costs as being ranges rather than fixed values. It is evident that the question of future solar PV for transmission expansion. Consequently, the future estimated cost projection for solar PV has been a point for solar PV should be dramatically changed "downward" going forward (i.e., significantly less of a cost

  2. High Resolution PV Power Modeling for Distribution Circuit Analysis

    SciTech Connect (OSTI)

    Norris, B. L.; Dise, J. H.

    2013-09-01

    NREL has contracted with Clean Power Research to provide 1-minute simulation datasets of PV systems located at three high penetration distribution feeders in the service territory of Southern California Edison (SCE): Porterville, Palmdale, and Fontana, California. The resulting PV simulations will be used to separately model the electrical circuits to determine the impacts of PV on circuit operations.

  3. Performance and Analysis of Photovoltaic (PV)Technologies

    E-Print Network [OSTI]

    Performance and Analysis of Photovoltaic (PV)Technologies at Selected Sites This report presents performance data from grid-connected PV systems located on Hawai`i Island, Maui, and O`ahu. Data was collected from PV systems produced by different manufacturers using a variety of technologies. The report

  4. Aalborg Universitet Remote and Centralized Monitoring of PV Power Plants

    E-Print Network [OSTI]

    Sera, Dezso

    Aalborg Universitet Remote and Centralized Monitoring of PV Power Plants Kopacz, Csaba; Spataru., & Kerekes, T. (2014). Remote and Centralized Monitoring of PV Power Plants. In Proceedings of the 14th from vbn.aau.dk on: juli 04, 2015 #12;Remote and Centralized Monitoring of PV Power Plants Csaba Kopacz

  5. Standardizing Appraisals for PV Installations Geoffrey T. Klise1

    E-Print Network [OSTI]

    Standardizing Appraisals for PV Installations Geoffrey T. Klise1 , Jamie L. Johnson2 , and Sandra K Gorda, FL, 33980, USA 3 Adomatis Appraisal Services, Punta Gorda, FL, 33951, USA ABSTRACT -- As PV to value the PV system as part of a property sale or re-finance. Proper valuation techniques as applied

  6. Performance Studies of PV: an Onthefly Modelchecker for

    E-Print Network [OSTI]

    Performance Studies of PV: an On­the­fly Model­checker for LTL­X Featuring Selective Caching 2001 Abstract We present an enumerative model­checker PV that uses a new partial order reduction al as with selective state caching very straightfor­ ward. We present a thorough evaluation of PV in terms of several

  7. SUPPLEMENTARY METHODS Strategies for microbial opsin expression in PV

    E-Print Network [OSTI]

    Schnitzer, Mark

    SUPPLEMENTARY METHODS Strategies for microbial opsin expression in PV::Cre mice. The simplest approach for microbial opsin expression in PV::Cre mice takes advantage of a cassette consisting of three) that can be excised by Cre recombinase in those PV neurons that express Cre. This approach has been used

  8. Modelling PV Deployment: A Tool Developed at CEEP to

    E-Print Network [OSTI]

    Delaware, University of

    Modelling PV Deployment: A Tool Developed at CEEP to Explore the Delaware Market Energy-3098 Website: http://ceep.udel.edu #12;Modeling PV Deployment: A Tool Developed at CEEP to Explore the Delaware..............................................................................................................................2 3. CEEP's Solar PV Diffusion Model Overview

  9. Report on PV Test Sites and Test Prepared for the

    E-Print Network [OSTI]

    Report on PV Test Sites and Test Protocols Prepared for the U.S. Department of Energy Office`i Distributed Energy Resource Technologies for Energy Security Revised Task 8 Deliverable PV Test Sites and Test. #12;1 Report on PV Test Sites and Test Protocols Table of Contents 1. Introduction

  10. PV MODULE PERFORMANCE AFTER 30 YEARS WITHOUT WASHING Frank Vignola

    E-Print Network [OSTI]

    Oregon, University of

    1 PV MODULE PERFORMANCE AFTER 30 YEARS WITHOUT WASHING Frank Vignola Josh Peterson Rich Kessler of a Solarex 40 watt mono crystalline PV module is examined after 30 years in use without washing. After photovoltaic (PV) modules? As the mod- ules are often on roof tops or situated out of the way, it often takes

  11. VADE-MECUM DE LA VORTICITE POTENTIELLE Dfinition (PV) P=

    E-Print Network [OSTI]

    Legras, Bernard

    VADE-MECUM DE LA VORTICITE POTENTIELLE Définition (PV) P= rot u2 Unité 1PVU = 106 K kg1 m2 s1 Pour les mouvements inviscides et adiabatiques, la PV est conservée pour chaque particule. Forme 102 s1 . La PV croît en magnitude vers les pôles. Ceci est dû à la croissance de |f| vers les pôles

  12. Distribution System Analysis Tools for Studying High Penetration of PV

    E-Print Network [OSTI]

    Distribution System Analysis Tools for Studying High Penetration of PV with Grid Support Features Electric Energy System #12;#12;Distribution System Analysis Tools for Studying High Penetration of PV project titled "Distribution System Analysis Tools for Studying High Penetration of PV with Grid Support

  13. pV3 Programmer's Guide Client Side & Concentrator Programming

    E-Print Network [OSTI]

    Peraire, Jaime

    pV3 Programmer's Guide Rev. 2.05 Client Side & Concentrator Programming Bob Haimes Massachusetts.I.T., and USER agrees to preserve same. 2 #12;Contents 1 Introduction 6 2 pV3 in the Message Passing Environment 7 2.1 Using PVM Message Passing with the Simulation . . . . . . . . . . . . . . . . . . . . 7 2.2 pV

  14. Role of Polycrystalline Thin-Film PV Technologies in Competitive PV Module Markets: Preprint

    SciTech Connect (OSTI)

    von Roedern, B.; Ullal, H. S.

    2008-05-01

    This paper discusses the developments in thin-film PV technologies and provides an outlook on future commercial module efficiencies achievable based on today's knowledge about champion cell performance.

  15. Solar Photovoltaic (PV) System Permit Application Checklist

    Office of Energy Efficiency and Renewable Energy (EERE)

    The Permit Application Checklist is intended to be used as a best management practice when establishing local government requirements for residential and commercial solar photovoltaic (PV) system permits. Local governments may modify this checklist to accommodate their local ordinances, code requirements, and permit procedures.

  16. Transforming PV Installations Toward Dispatchable, Schedulable...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    B C N A B C N A B C N A B C N Ai n Bi n Ci n Aout Bout Cout A B C N A B C N Transforming PV insTallaTions Toward disPaTchable, schedulable energy soluTions MIChAEl MIllS-PrICE,...

  17. Analysis and Design of Smart PV Module 

    E-Print Network [OSTI]

    Mazumdar, Poornima

    2012-12-10

    the individual dc-dc converters and control the output AC voltages directly, thus becoming a true plug and power energy system. Such a concept is ideal for curved surfaces such as building integrated PV (BIPV) system applications where gradients of insolation...

  18. PV Solar Site Assessment (Milwaukee High School)

    Broader source: Energy.gov [DOE]

    The purpose of this assessment is to provide site-specific information on how a solar electric (also referred to as a photovoltaic, or PV) system would perform at your location, including information on estimated physical size, rated output, energy production, costs, financial incentives and mounting options. Site assessors are required to present unbiased information and may not recommend contractors or products.

  19. 2 IAEI NEWS September . October 2011 www.iaei.org perspectives on pv

    E-Print Network [OSTI]

    Johnson, Eric E.

    2 IAEI NEWS September . October 2011 www.iaei.org perspectives on pv www.iaei.org September . October 2011 IAEI NEWS 3 perspectives on pv P hotovoltaic (PV) power systems have PV modules and PV arrays will be supplied to local loads and to the con- nected utility grid. There are two areas of PV systems that deserve

  20. Mathematical Modeling for CostMathematical Modeling for Cost Optimization of PV RecyclingOptimization of PV Recycling

    E-Print Network [OSTI]

    Bergman, Keren

    Mathematical Modeling for CostMathematical Modeling for Cost Optimization of PV Recycling of plants Capital costs to open up a recycling center 4 #12;Time Horizon for PV Recycling Infrastructure 5 cost $189K System optimal cost $1079K 11 #12;PV Recycling ­Cost Optimization 1. Where is the optimized

  1. The Effect of PV Array Size and Battery Size on the Economics of PV/Diesel/Battery Hybrid RAPS Systems

    E-Print Network [OSTI]

    The Effect of PV Array Size and Battery Size on the Economics of PV/Diesel/Battery Hybrid RAPS WA 6150 Abstract This paper focuses on pv/diesel/battery hybrid RAPS systems meeting loads above 50 kWh. INTRODUCTION A diesel hybrid system, incorporating a battery and inverter, can often provide power at a lower

  2. Ensuring Safe Shipment of Hazardous Materials | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n cEnergyNatural GasDepartmentApril 13,truck carries a waste shipment from

  3. Hanford Shipment Arrives Safely At Waste Isolation Pilot Plant

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would likeUniverse (Journalvivo Low-Dose Low34October 201422T Office36ZHanford Shipment

  4. Milestone reached: Waste shipment leaves Los Alamos National Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformationJessework uses concrete7 Assessment ofLana7, atScienceWaste shipment leaves

  5. On the pure virtual braid group $PV_3$

    E-Print Network [OSTI]

    Bardakov, V G; Vershinin, V V; Wu, J

    2009-01-01

    In this article, we investigate various properties of the pure virtual braid group PV_3. From its canonical presentation, we obtain a free product decomposition of PV_3. As a consequence, we show that PV_3 is residually torsion free nilpotent, which implies that the set of finite type invariants in the sense of Goussarov-Polyak-Viro is complete for virtual pure braids with three strands. Moreover we prove that the presentation of PV_3 is aspherical. Finally we determine the cohomology ring and the associated graded Lie algebra of PV_3.

  6. 2001 annual report 2001 annual report

    E-Print Network [OSTI]

    New Mexico, University of

    2001 annual report 2001 annual report 2001 annual report 2001 annual report 2001 annual report 2001 annual report 2001 annual report 2001 annual reportelectrical & computer engineering 2001 annual report the university of new mexico department of 2001 annual report 2001 annual report 2001 annual report 2001 annual

  7. Materials Testing for PV Module Encapsulation

    SciTech Connect (OSTI)

    Jorgensen, G.; Terwilliger, K.; Glick, S.; Pern, J.; McMahon, T.

    2003-05-01

    Important physical properties of materials used in PV module packaging are presented. High-moisture-barrier, high-resistivity, adhesion-promoting coatings on polyethyl-ene terephthalate (PET) films have been fabricated and characterized for use in PV module application and com-pared to standard polymer backsheet materials. Ethylene vinyl acetate (EVA) and an encapsulant replacement for EVA are studied for their water vapor transmission rate (WVTR) and adhesion properties. WVTR, at test conditions up to 85C/100% relative humidity (RH), and adhesion val-ues are measured before and after filtered xenon arc lamp ultraviolet (UV) exposure and damp heat exposure at 85C/85% RH. Water ingress is quantified by weight gain and embedded humidity sensors.

  8. Cascaded Microinverter PV System for Reduced Cost

    SciTech Connect (OSTI)

    Bellus, Daniel R.; Ely, Jeffrey A.

    2013-04-29

    In this project, a team led by Delphi will develop and demonstrate a novel cascaded photovoltaic (PV) inverter architecture using advanced components. This approach will reduce the cost and improve the performance of medium and large-sized PV systems. The overall project objective is to develop, build, and test a modular 11-level cascaded three-phase inverter building block for photovoltaic applications and to develop and analyze the associated commercialization plan. The system will be designed to utilize photovoltaic panels and will supply power to the electric grid at 208 VAC, 60 Hz 3-phase. With the proposed topology, three inverters, each with an embedded controller, will monitor and control each of the cascade sections, reducing costs associated with extra control boards. This report details the final disposition on this project.

  9. AIR SHIPMENT OF HIGHLY ENRICHED URANIUM SPENT NUCLEAR FUEL FROM ROMANIA AND LIBYA

    SciTech Connect (OSTI)

    Christopher Landers; Igor Bolshinsky; Ken Allen; Stanley Moses

    2010-07-01

    In June 2009 Romania successfully completed the world’s first air shipment of highly enriched uranium (HEU) spent nuclear fuel transported in Type B(U) casks under existing international laws and without special exceptions for the air transport licenses. Special 20-foot ISO shipping containers and cask tiedown supports were designed to transport Russian TUK 19 shipping casks for the Romanian air shipment and the equipment was certified for all modes of transport, including road, rail, water, and air. In December 2009 Libya successfully used this same equipment for a second air shipment of HEU spent nuclear fuel. Both spent fuel shipments were transported by truck from the originating nuclear facilities to nearby commercial airports, were flown by commercial cargo aircraft to a commercial airport in Yekaterinburg, Russia, and then transported by truck to their final destinations at the Production Association Mayak facility in Chelyabinsk, Russia. Both air shipments were performed under the Russian Research Reactor Fuel Return Program (RRRFR) as part of the U.S. National Nuclear Security Administration (NNSA) Global Threat Reduction Initiative (GTRI). The Romania air shipment of 23.7 kg of HEU spent fuel from the VVR S research reactor was the last of three HEU fresh and spent fuel shipments under RRRFR that resulted in Romania becoming the 3rd RRRFR participating country to remove all HEU. Libya had previously completed two RRRFR shipments of HEU fresh fuel so the 5.2 kg of HEU spent fuel air shipped from the IRT 1 research reactor in December made Libya the 4th RRRFR participating country to remove all HEU. This paper describes the equipment, preparations, and license approvals required to safely and securely complete these two air shipments of spent nuclear fuel.

  10. Annual Report: Photovoltaic Subcontract Program FY 1990

    SciTech Connect (OSTI)

    Summers, K. A.

    1991-03-01

    This report summarizes the progress of the Photovoltaic (PV) Subcontract Program of the Solar Energy Research Institute (SERI) from October 1, 1989 through September 30, 1990. The PV Subcontract Program is responsible for managing the subcontracted portion of SERI's PV Advanced Research and Development Project. In fiscal year 1990, this included more than 54 subcontracts with a total annualized funding of approximately $11.9 million. Approximately two-thirds of the subcontracts were with universities at a total funding of nearly $3.3 million. The six technical sections of the report cover the main areas of the subcontract program: the Amorphous Silicon Research Project, Polycrystalline Thin Films, Crystalline Silicon Materials Research, High-Efficiency Concepts, the New Ideas Program, and the University Participation Program. Technical summaries of each of the subcontracted programs provide a discussion of approaches, major accomplishments in FY 1990, and future research directions. Another section introduces the PVMaT project and reports on its progress.

  11. Real Power and Reactive Power Control of a Three-Phase Single-Stage-PV System and PV voltage Stability

    SciTech Connect (OSTI)

    Li, Huijuan; Xu, Yan; Adhikari, Sarina; Rizy, D Tom; Li, Fangxing; Irminger, Philip

    2012-01-01

    Grid-connected photovoltaic (PV) systems with power electronic interfaces can provide both real and reactive power to meet power system needs with appropriate control algorithms. This paper presents the control algorithm design for a three-phase single-stage grid-connected PV inverter to achieve either maximum power point tracking (MPPT) or a certain amount of real power injection, as well as the voltage/var control. The switching between MPPT control mode and a certain amount of real power control mode is automatic and seamless. Without the DC-to-DC booster stage, PV DC voltage stability is an important issue in the control design especially when the PV inverter is operating at maximum power point (MPP) with voltage/var control. The PV DC voltage collapse phenomenon and its reason are discussed. The method based on dynamic correction of the PV inverter output is proposed to ensure PV DC voltage stability. Simulation results of the single-stage PV system during system disturbances and fast solar irradiation changes confirm that the proposed control algorithm for single-stage PV inverters can provide appropriate real and reactive power services and ensure PV DC voltage stability during dynamic system operation and atmospheric conditions.

  12. A two-genome microarray for the rice pathogens Xanthomonas oryzae pv. oryzae and X. oryzae pv. oryzicola and its use in the discovery of a difference in their regulation of hrp genes.

    E-Print Network [OSTI]

    2008-01-01

    of Xanthomonas oryzae pv. oryzae hrp Genes in XOM2, a Novelin Xanthomonas oryzae pv. oryzae. Journal of bacteriologyrice by Xanthomonas oryzae pv. oryzicola. Mol Plant-Microbe

  13. Extensions of models of PV Jan Kraj'icek \\Lambda

    E-Print Network [OSTI]

    Krajíèek, Jan

    Extensions of models of PV Jan Kraj'iŸcek \\Lambda Mathematical Institute and Institute of Computer Science Academy of Sciences of the Czech Republic Abstract We prove that certain models of PV in which NP 6` P=poly have a \\Pi b 1 ­elementary extension to a model of (PV and) NP 6` coNP=poly. If S2 proves

  14. Power Systems Engineering Research Center Modeling, Analysis and Deployment of High PV

    E-Print Network [OSTI]

    Van Veen, Barry D.

    Power Systems Engineering Research Center Modeling, Analysis and Deployment of High PV Penetration with field measurements. The model corresponds to an actual PV and DAS installation by Arizona Public Service and about 125 rooftop residential PV systems and two large scale PV systems. The total installed PV capacity

  15. The following contribution was presented at the 28. European PV Solar Energy Conference and Exhibition

    E-Print Network [OSTI]

    The following contribution was presented at the 28. European PV Solar Energy Conference, Paris, France, 30th Sep. -3rd Oct. 2013, 4DO.2.1 1 IMPACT OF TRANSPORTATION ON SILICON WAFER-BASED PV: Before a PV module is integrated into a PV system it has to be handled and transported. This part of a PV

  16. EXECUTIVE SUMMARY: RETHINKING STANDBY & FIXED COST CHARGES REGULATORY & RATE DESIGN PATHWAYS TO DEEPER SOLAR PV COST

    E-Print Network [OSTI]

    PV technology, however, PV-specific charges will negatively impact the solar PV cost reduction goals TO DEEPER SOLAR PV COST REDUCTIONS The Current Terrain In recent years, electric utilities have experienced business models almost exclusively to the rapid growth of distributed solar PV. This focus has led

  17. Keywords: Photovoltaic System, fault-tolerance, recon-figurable PV panel

    E-Print Network [OSTI]

    Pedram, Massoud

    1 Keywords: Photovoltaic System, fault-tolerance, recon- figurable PV panel Photovoltaic (PV and the advancement of PV device technologies. PV systems have been widely deployed in electric vehicles, homes, power plants, and satellites. The output power of a PV cell (also called solar cell) is dependent on the solar

  18. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim

    2010-01-01

    distributed photovoltaics (PV) adoption. 1 Though specificfor supporting distributed PV adoption. 11 Though specificin distributed PV, which could thwart broader adoption. Many

  19. Global Solar Photovoltaic (PV) Installation Market to be Propelled...

    Open Energy Info (EERE)

    Global Solar Photovoltaic (PV) Installation Market to be Propelled by Greater Concerns over Carbon Footprint Home > Groups > Renewable Energy RFPs John55364's picture Submitted by...

  20. Transforming PV Installations toward Dispatchable, Schedulable Energy Solutions

    Office of Energy Efficiency and Renewable Energy (EERE)

    Advanced Energy (AE) will address three important needs in the further deployment of photovoltaic (PV) systems: 1) demonstrating and commercializing a new anti-islanding method utilizing Phasor...

  1. Smart-Grid Ready PV Inverters with Utility Communication

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    INTEGRATION Smart-Grid Ready PV Inverters with Utility Communication Electric Power Research Institute Brian Seal, Tom Key, Aminul Huque, Lindsey Rogers Technical Contact Brian...

  2. Instrumentation for Evaluating PV System Performance Losses from Snow: Preprint

    SciTech Connect (OSTI)

    Marion, B.; Rodriguez, J.; Pruett, J.

    2009-04-01

    Describes the use of a pyranometer with a heater and a digital camera to determine losses related to snow for PV systems located at National Renewable Energy Laboratory.

  3. NREL: News - NREL Releases Report Describing Guidelines for PV...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Printable Version News Release NR-1615 NREL Releases Report Describing Guidelines for PV Manufacturer Quality Assurance International task force aims to toughen standards,...

  4. NREL: News - NREL Supports China PV Investment and Financing...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Newsroom Bookmark and Share Printable Version News Release NR-2115 NREL Supports China PV Investment and Financing Alliance to Open Capital for Solar Deployment May 14, 2015 The...

  5. High?Penetration PV with Advanced Power Conditioning Systems

    Office of Energy Efficiency and Renewable Energy (EERE)

    Virginia Polytechnic Institute and State University (VT) is evaluating the impacts of high photovoltaic (PV) penetration and methods to manage any impacts with improved power conditioning equipment.

  6. Solar America Initiative (SAI) PV Technology Incubator Program: Preprint

    SciTech Connect (OSTI)

    Keyes, B.; Symko-Davies, M.; Mitchell, R.; Ullal H.; von Roedern, B.; Greene, L.; Stephens, S.

    2008-05-01

    The SAI PV Technology Incubator Program is designed to accelerate technologies/prodesses that have successfully demonstrated a proof-of-concept/process in a laboratory.

  7. Water Impacts of High Solar PV Electricity Penetration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Water Impacts of High Solar PV Electricity Penetration Jordan Macknick and Stuart Cohen National Renewable Energy Laboratory (NREL) Technical Report NRELTP-6A20-63011 September...

  8. Estimating Rooftop Suitability for PV: A Review of Methods, Patents...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    For researchers looking to understand the market potential of rooftop-installed photovoltaics (PV) in particular, understanding the amount and characteristics of rooftop space...

  9. Sandia Energy - Sandia Will Host PV Bankability Workshop at Solar...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Will Host PV Bankability Workshop at Solar Power International (SPI) 2013 Home Renewable Energy Energy Facilities Grid Integration Partnership News Distribution Grid Integration...

  10. Sandia Energy - PV Performance Modeling Collaborative's New and...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Modeling & Simulation Solar Newsletter Photovoltaic Systems Evaluation Laboratory (PSEL) PV Performance Modeling Collaborative's New and Improved Website Is Launched Previous Next...

  11. Sandia Energy - Sandia to host PV Bankability workshop at Solar...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    host PV Bankability workshop at Solar Power International (SPI) 2013 Home Renewable Energy Energy Events Workshops News & Events Solar Conferences Seminars & Conferences Sandia to...

  12. NREL Supports China PV Investment and Financing Alliance to Open...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Supports China PV Investment and Financing Alliance to Open Capital for Solar Deployment May 14, 2015 The Energy Department's National Renewable Energy Laboratory (NREL) and the...

  13. Maricopa Assn. of Governments - PV and Solar Domestic Water Heating...

    Broader source: Energy.gov (indexed) [DOE]

    necessary electricalbuilding permits for residential (single-family) and commercial PV systems. These procedures are a part of the MAG Building Code Standards. The standards...

  14. PV Arc Fault Detector Challenges Due to Module Frequency Response...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    This poster does not contain any proprietary or confidential information. Introduction PV system arc faults have led to a number of rooftop fires which have caused significant...

  15. Strategic Sequencing for State Distributed PV Policies: A Quantitative...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    in spurring the development of customer-sited distributed generation (DG), in particular solar photovoltaic (PV) markets. Prompted by that interest, this analysis examines the use...

  16. Development of a Dispatchable PV Peak Shainv System. PV: Bonus Program - Phase 1 Report. Volume 1

    SciTech Connect (OSTI)

    1995-10-01

    This report summarizes the work performed by Delmarva Power and Light and its subcontractors in Phase 1 of the US Department of Energy's PV:BONUS Program. The purpose of the program is to develop products and systems for buildings which utilize photovoltaic (N) technology. Beginning with a cooperative research effort with the University of Delaware's Center for Energy and Environmental Policy Research Delmarva Power developed and demonstrated the concept of Dispatchable PV Peak Shaving. This concept and the system which resulted horn the development work are unique from other grid-connected PV systems because it combines a PV, battery energy storage, power conversion and control technologies into an integrated package. Phase 1 began in July 1993 with the installation of a test and demonstration system at Delmarva's Northern Division General Office building near Newark, Delaware. Following initial testing throughout the summer and fall of 1993, significant modifications were made under an amendment to the DOE contract. Work on Phase 1 concluded in the early spring of 1995. Significant progress towards the goal of commercializing the system was made during Phase 1, and is summarized. Based on progress in Phase 1, a proposal to continue the work in Phase 2 was submitted to the US DOE in May 1995. A contract amendment and providing funds for the Phase 2 work is expected in July 1995.

  17. Zhonghuite PV Technology Co | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page| Open Energy Information Serbia-EnhancingEtGeorgia:Illinois:WizardYates County,Zena, New York:ShuqimengZhonghuite PV

  18. Integrating Solar PV in Utility System Operations

    SciTech Connect (OSTI)

    Mills, A.; Botterud, A.; Wu, J.; Zhou, Z.; Hodge, B-M.; Heany, M.

    2013-10-31

    This study develops a systematic framework for estimating the increase in operating costs due to uncertainty and variability in renewable resources, uses the framework to quantify the integration costs associated with sub-hourly solar power variability and uncertainty, and shows how changes in system operations may affect these costs. Toward this end, we present a statistical method for estimating the required balancing reserves to maintain system reliability along with a model for commitment and dispatch of the portfolio of thermal and renewable resources at different stages of system operations. We estimate the costs of sub-hourly solar variability, short-term forecast errors, and day-ahead (DA) forecast errors as the difference in production costs between a case with “realistic” PV (i.e., subhourly solar variability and uncertainty are fully included in the modeling) and a case with “well behaved” PV (i.e., PV is assumed to have no sub-hourly variability and can be perfectly forecasted). In addition, we highlight current practices that allow utilities to compensate for the issues encountered at the sub-hourly time frame with increased levels of PV penetration. In this analysis we use the analytical framework to simulate utility operations with increasing deployment of PV in a case study of Arizona Public Service Company (APS), a utility in the southwestern United States. In our analysis, we focus on three processes that are important in understanding the management of PV variability and uncertainty in power system operations. First, we represent the decisions made the day before the operating day through a DA commitment model that relies on imperfect DA forecasts of load and wind as well as PV generation. Second, we represent the decisions made by schedulers in the operating day through hour-ahead (HA) scheduling. Peaking units can be committed or decommitted in the HA schedules and online units can be redispatched using forecasts that are improved relative to DA forecasts, but still imperfect. Finally, we represent decisions within the operating hour by schedulers and transmission system operators as real-time (RT) balancing. We simulate the DA and HA scheduling processes with a detailed unit-commitment (UC) and economic dispatch (ED) optimization model. This model creates a least-cost dispatch and commitment plan for the conventional generating units using forecasts and reserve requirements as inputs. We consider only the generation units and load of the utility in this analysis; we do not consider opportunities to trade power with neighboring utilities. We also do not consider provision of reserves from renewables or from demand-side options. We estimate dynamic reserve requirements in order to meet reliability requirements in the RT operations, considering the uncertainty and variability in load, solar PV, and wind resources. Balancing reserve requirements are based on the 2.5th and 97.5th percentile of 1-min deviations from the HA schedule in a previous year. We then simulate RT deployment of balancing reserves using a separate minute-by-minute simulation of deviations from the HA schedules in the operating year. In the simulations we assume that balancing reserves can be fully deployed in 10 min. The minute-by-minute deviations account for HA forecasting errors and the actual variability of the load, wind, and solar generation. Using these minute-by-minute deviations and deployment of balancing reserves, we evaluate the impact of PV on system reliability through the calculation of the standard reliability metric called Control Performance Standard 2 (CPS2). Broadly speaking, the CPS2 score measures the percentage of 10-min periods in which a balancing area is able to balance supply and demand within a specific threshold. Compliance with the North American Electric Reliability Corporation (NERC) reliability standards requires that the CPS2 score must exceed 90% (i.e., the balancing area must maintain adequate balance for 90% of the 10-min periods). The combination of representing DA forecast errors in the

  19. Hunan Huayuan PV | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LISTStar2-0057-EA JumpDuimen RiverScoring ToolHuaihua Power Group Co Ltd Jump to:PV

  20. Teksun PV Manufacturing Inc | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX ECoop Inc JumpHeter BatterySolarfinMarketMemberI PLLC JumpJumpTecnosignalTeksun PV

  1. Tokyo Electron PV | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX ECoop Inc JumpHeterInformation PolicyTinna Group Jump to:Tokuyama CorporationPV Jump

  2. Solar PV Incentive Programs | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankADVANCED MANUFACTURINGEnergy BillsNo.Hydrogen4Energy SmoothEquipment CertificationSolarSoft CostsPV

  3. The Open PV Project | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Financing ToolInternational Affairs,Department of Energy The FinalThisTheThe Open PV Project

  4. All Solar PV | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LIST OFAMERICA'S FUTURE.EnergyWoodenDateSA JumpSolar PV Jump to: navigation,

  5. Gansu PV Co Ltd | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LIST OFAMERICA'SHeavy ElectricalsFTL Solar JumpNetworkingGAOHGWTianjinJieyuanPV Co Ltd

  6. Generation PV Inc | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LIST OFAMERICA'SHeavy ElectricalsFTL SolarGate Solar Jump to:GenDriveMining ActPV Inc

  7. Sandia Energy - PV Modeling & Analysis

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II)Geothermal Energy &WaterNew CREWOnline Abstracts andPV Modeling &

  8. Sandia Energy - PV Value®

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II)Geothermal Energy &WaterNew CREWOnline AbstractsSystems ReliabilityPV

  9. Safety evaluation for packaging 222-S laboratory cargo tank for onetime type B material shipment

    SciTech Connect (OSTI)

    Nguyen, P.M.

    1994-08-19

    The purpose of this Safety Evaluation for Packaging (SEP) is to evaluate and document the safety of the onetime shipment of bulk radioactive liquids in the 222-S Laboratory cargo tank (222-S cargo tank). The 222-S cargo tank is a US Department of Transportation (DOT) MC-312 specification (DOT 1989) cargo tank, vehicle registration number HO-64-04275, approved for low specific activity (LSA) shipments in accordance with the DOT Title 49, Code of Federal Regulations (CFR). In accordance with the US Department of Energy, Richland Operations Office (RL) Order 5480.1A, Chapter III (RL 1988), an equivalent degree of safety shall be provided for onsite shipments as would be afforded by the DOT shipping regulations for a radioactive material package. This document demonstrates that this packaging system meets the onsite transportation safety criteria for a onetime shipment of Type B contents.

  10. Recovery Act Funding Leads to Record Year for Transuranic Waste Shipments

    Broader source: Energy.gov [DOE]

    With the help of American Recovery and Reinvestment Act funding, the Waste Isolation Pilot Plant (WIPP) received the most transuranic waste shipments in a single year since waste operations began...

  11. Packaging and Transportation for Offsite Shipment of Materials of National Security Interest

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2010-12-20

    The purpose of this Order is to make clear that the packaging and transportation of all offsite shipments of materials of national security interest for DOE must be conducted in accordance with DOT and Nuclear Regulatory Commission (NRC) regulations that would be applicable to comparable commercial shipments, except where an alternative course of action is identified in this Order. Supersedes DOE O 461.1A.

  12. Realisation of the full potential of PV Extract of report from workgroup 4 in EU's PV Technology Platform by Peter Ahm.

    E-Print Network [OSTI]

    Realisation of the full potential of PV Extract of report from workgroup 4 in EU's PV Technology. Realisation of the full potential of PV as an important and integral part of our energy supply to those that use it. There is thus an imperative to facilitate and promote education on PV

  13. Analyzing and simulating the variability of solar irradiance and solar PV powerplants

    E-Print Network [OSTI]

    Lave, Matthew S.

    2012-01-01

    We appreciate funding from the DOE High Solar PV PenetrationWe appreciate funding from the DOE High Solar PV PenetrationWe appreciate funding from the DOE High Solar PV Penetration

  14. Comparison Between TRNSYS Software Simulation and PV F-Chart Program on Photovoltaic System 

    E-Print Network [OSTI]

    Haberl, J. S.; Baltazar, J. C.; Mao, C.

    2012-01-01

    This report covers the comparisons of Photovoltaic System by TRNSYS simulation and PV F-Chart program to test TRNSYS simulation accuracy. The report starts with the Photovoltaic (PV) (PV) System introduction in Section one which is followed...

  15. Step-Stress Accelerated Degradation Testing (SSADT) for Photovoltaic (PV) Devices and Cells (Presentation)

    SciTech Connect (OSTI)

    Lee, J.; Elmore, R.; Suh, C.; Jones, W.

    2010-10-01

    Presentation on step-stress accelerated degradation testing (SSADT) for photovoltaics (PV). Developed are a step-stress degradation test (SSADT) for PV reliability tests and a lifetime prediction model for PV products.

  16. City of Anaheim This page outlines solar PV incentives, financing mechanisms, permitting process, and

    E-Print Network [OSTI]

    City of Anaheim This page outlines solar PV incentives, financing mechanisms, permitting process Apply for local permits Install your PV system Arrange for your PV system to be interconnected to your

  17. U.S. Aims for Zero-Energy: Support for PV on New Homes

    E-Print Network [OSTI]

    Barbose, Galen; Wiser, Ryan; Bolinger, Mark

    2006-01-01

    Approved Figure 1. Relative Cost of PV on New, Market-Rateretrofits. The higher cost of PV on individual or smallables Buy-Dow n Program: Cost of PV on New Homes Compared to

  18. New Berkeley Lab Report Tracks a Decade of PV Installed Cost Trends

    E-Print Network [OSTI]

    Barbose, Galen

    2009-01-01

    Tracks a Decade of PV Installed Cost Trends Galen Barbose,in total average PV installed costs since 1998 appears to beNew York) exempted PV hardware costs from state sales tax

  19. Approaches To Integrating A HIgh Penertration Of Solar PV and CPV Onto The Electrical Grid

    E-Print Network [OSTI]

    Hill, Steven Craig

    2013-01-01

    for peaking or base load generation and PV cost. The paper1) the break-even cost of PV is unacceptably high unless PVlarge scale PV inverters due to the cost of energy storage

  20. The Economic Value of PV and Net Metering to Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim

    2010-01-01

    for which TOU Rate is Least Cost PV Penetration Level PG&E (Monthly Netting costs from distributed PV generally suggestsavoided T&D capacity costs from distributed PV have derived

  1. Shaking Up the Residential PV Market: Implications of Recent Changes to the ITC

    E-Print Network [OSTI]

    Bolinger, Mark

    2008-01-01

    Empirical Investigation of PV Cost Trends, and Implicationspart of the cost of supporting residential PV to the federal56% of the installed cost of a commercial PV system, 12 are

  2. Enabling Broad Adoption of Distributed PV-storage systems Via Supervisory Planning & Control

    E-Print Network [OSTI]

    DeForest, Nicholas

    2014-01-01

    impact of wide-spread PV adoption for utilities, by creatingEnabling broad adoption of distributed PV-storage systemsEnabling broad adoption of distributed PV-storage systems

  3. Ectopic expression of rice Xa21 overcomes developmentally controlled resistance to Xanthomonas oryzae pv. oryzae.

    E-Print Network [OSTI]

    2010-01-01

    of Xanthomonas oryzae pv. oryzae AvrXa21 and implicationsto Xanthomonas oryzae pv. oryzae Chang-Jin Park a , Sang-Wonreceptor XA21 Xanthomonas oryzae pv. oryzae a b s t r a c t

  4. Genome sequence and rapid evolution of the rice pathogen Xanthomonas oryzae pv. oryzae PXO99A.

    E-Print Network [OSTI]

    2008-01-01

    relationships among X. oryzae pv. oryzae (Xoo) strains PXO99MAFF311018, and X. oryzae pv. oryzicola (Xoc) strain BLS256biology of Xanthomonas oryzae pv. oryzae and approaches to

  5. U.S. Aims for Zero-Energy: Support for PV on New Homes

    E-Print Network [OSTI]

    Barbose, Galen; Wiser, Ryan; Bolinger, Mark

    2006-01-01

    Figure 1. Relative Cost of PV on New, Market-Rate Homesfor Zero-Energy: Support for PV on New Homes Galen Barbose,segment for solar photovoltaic (PV) adoption, new homes have

  6. Exploring the Economic Value of EPAct 2005's PV Tax Credits

    E-Print Network [OSTI]

    Bolinger, Mark A

    2010-01-01

    to support a greater number PV systems at the reduced grantEconomic Value of EPAct 2005’s PV Tax Credits Mark Bolingerfor grid-connected photovoltaics (PV) in the US has grown

  7. New Berkeley Lab Report Tracks a Decade of PV Installed Cost Trends

    E-Print Network [OSTI]

    Barbose, Galen

    2009-01-01

    Thus, even if large commercial PV installations continue tojoined by utility-scale PV), the removal of the cap on theLab Report Tracks a Decade of PV Installed Cost Trends Galen

  8. Exploring the Economic Value of EPAct 2005's PV Tax Credits

    E-Print Network [OSTI]

    Bolinger, Mark; Wiser, Ryan; Ing, Edwin

    2006-01-01

    Exploring the Economic Value of EPAct 2005’s PV Tax CreditsEconomic Value of EPAct 2005’s PV Tax Credits Mark Bolingerfor grid-connected photovoltaics (PV) in the US has grown

  9. BRST Invariant PV Regularization of SUSY Yang-Mills and SUGRA

    E-Print Network [OSTI]

    Gaillard, Mary K

    2012-01-01

    September 2011 BRST Invariant PV Regularization of SUSYemployer. ii BRST INVARIANT PV REGULARIZATION OF SUSY YANG-a number of years on Pauli-Villars (PV) regu- larization of

  10. Do PV Systems Increase Residential Selling Prices If So, How Can Practitioners Estimate This Increase?

    E-Print Network [OSTI]

    Hoen, Ben

    2013-01-01

    No. DE-AC02-05CH11231. Do PV Systems Increase Residentialimpacts of photovoltaic (PV) energy systems on home salesthat existing homes with PV systems sold for a premium over

  11. Shaking Up the Residential PV Market: Implications of Recent Changes to the ITC

    E-Print Network [OSTI]

    Bolinger, Mark

    2008-01-01

    Shaking Up the Residential PV Market: Implications of Recentfor commercial photovoltaic (PV) systems from 10% to 30% of2005’s solar tax credits on PV system owners, in light of

  12. The Economic Value of PV and Net Metering to Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim

    2010-01-01

    a Substantial Benefit of Solar PV”, The Electricity Journal,2008. MRW & Associates. “Solar PV and Retail Rate Design”,The Economic Value of PV and Net Metering to Residential

  13. Approaches To Integrating A HIgh Penertration Of Solar PV and CPV Onto The Electrical Grid

    E-Print Network [OSTI]

    Hill, Steven Craig

    2013-01-01

    100] A Study of Dispersed PV Generation on the PSO Systempaper .pdf [148] Solar PV Carousel Trackers For BuildingBOS in an Optimized 3.5 MW PV installation Maon, J. et al.

  14. Approaches To Integrating A HIgh Penertration Of Solar PV and CPV Onto The Electrical Grid

    E-Print Network [OSTI]

    Hill, Steven Craig

    2013-01-01

    63  Off?Grid (Stand?Alone) PV Power System not well established. OFF-GRID (STAND-ALONE) PV POWER SYSTEMvariability characteristics of off-grid PV power systems and

  15. Oxynitride Thin Film Barriers for PV Packaging

    SciTech Connect (OSTI)

    Glick, S. H.; delCueto, J. A.; Terwilliger, K. M.; Jorgensen, G. J.; Pankow, J. W.; Keyes, B. M.; Gedvilas, L. M.; Pern, F. J.

    2005-11-01

    Dielectric thin-film barrier and adhesion-promoting layers consisting of silicon oxynitride materials (SiOxNy, with various stoichiometry) were investigated. For process development, films were applied to glass (TCO, conductive SnO2:F; or soda-lime), polymer (PET, polyethylene terephthalate), aluminized soda-lime glass, or PV cell (a-Si, CIGS) substrates. Design strategy employed de-minimus hazard criteria to facilitate industrial adoption and reduce implementation costs for PV manufacturers or suppliers. A restricted process window was explored using dilute compressed gases (3% silane, 14% nitrous oxide, 23% oxygen) in nitrogen (or former mixtures, and 11.45% oxygen mix in helium and/or 99.999% helium dilution) with a worst-case flammable and non-corrosive hazard classification. Method employed low radio frequency (RF) power, less than or equal to 3 milliwatts per cm2, and low substrate temperatures, less than or equal to 100 deg C, over deposition areas less than or equal to 1000 cm2. Select material properties for barrier film thickness (profilometer), composition (XPS/FTIR), optical (refractive index, %T and %R), mechanical peel strength and WVTR barrier performance are presented.

  16. Grid-tied PV battery systems.

    SciTech Connect (OSTI)

    Barrett, Keith Phillip; Gonzalez, Sigifredo; Hund, Thomas D.

    2010-09-01

    Grid tied PV energy smoothing was implemented by using a valve regulated lead-acid (VRLA) battery as a temporary energy storage device to both charge and discharge as required to smooth the inverter energy output from the PV array. Inverter output was controlled by the average solar irradiance over the previous 1h time interval. On a clear day the solar irradiance power curve is offset by about 1h, while on a variable cloudy day the inverter output power curve will be smoothed based on the average solar irradiance. Test results demonstrate that this smoothing algorithm works very well. Battery state of charge was more difficult to manage because of the variable system inefficiencies. Testing continued for 30-days and established consistent operational performance for extended periods of time under a wide variety of resource conditions. Both battery technologies from Exide (Absolyte) and East Penn (ALABC Advanced) proved to cycle well at a Partial state of charge over the time interval tested.

  17. Impact of residential PV adoption on Retail Electricity Rates

    SciTech Connect (OSTI)

    Cai, DWH; Adlakha, S; Low, SH; De Martini, P; Chandy, KM

    2013-11-01

    The price of electricity supplied from home rooftop photo voltaic (PV) solar cells has fallen below the retail price of grid electricity in some areas. A number of residential households have an economic incentive to install rooftop PV systems and reduce their purchases of electricity from the grid. A significant portion of the costs incurred by utility companies are fixed costs which must be recovered even as consumption falls. Electricity rates must increase in order for utility companies to recover fixed costs from shrinking sales bases. Increasing rates will, in turn, result in even more economic incentives for customers to adopt rooftop PV. In this paper, we model this feedback between PV adoption and electricity rates and study its impact on future PV penetration and net-metering costs. We find that the most important parameter that determines whether this feedback has an effect is the fraction of customers who adopt PV in any year based solely on the money saved by doing so in that year, independent of the uncertainties of future years. These uncertainties include possible changes in rate structures such as the introduction of connection charges, the possibility of PV prices dropping significantly in the future, possible changes in tax incentives, and confidence in the reliability and maintainability of PV. (C) 2013 Elsevier Ltd. All rights reserved.

  18. The PV Song As first performed at the Cambridge GEFD

    E-Print Network [OSTI]

    Cambridge, University of

    The PV Song As first performed at the Cambridge GEFD Summer School, Friday 22 Sept 2006 RevisedLennon-McCartney-Nielsen-Wagner-McIntyre Lyrics by Nick Hall and John Thuburn The PV Song First performed at the Cambridge GEFD Summer School

  19. Encouraging PV Adoption in New Market-Rate Residential Construction: A Critical Review of Program Experiences to Date

    E-Print Network [OSTI]

    Barbose, Galen; Wiser, Ryan; Bolinger, Mark

    2006-01-01

    ENCOURAGING PV ADOPTION IN NEW MARKET-RATE RESIDENTIALAs a market segment for PV adoption, new homes have a numberPV as an option is that PV adoption then becomes contingent

  20. Status of High Performance PV: Polycrystalline Thin-Film Tandems

    SciTech Connect (OSTI)

    Symko-Davies, M.

    2005-02-01

    The High-Performance Photovoltaic (HiPerf PV) Project was initiated by the U.S. Department of Energy to substantially increase the viability of photovoltaics (PV) for cost-competitive applications so that PV can contribute significantly to our energy supply and our environment. The HiPerf PV Project aims at exploring the ultimate performance limits of existing PV technologies, approximately doubling their sunlight-to-electricity conversion efficiencies during its course. This work includes bringing thin-film cells and modules toward 25% and 20% efficiencies, respectively, and developing multijunction concentrator cells and modules able to convert more than one-third of the sun's energy to electricity (i.e., 33% efficiency). This paper will address recent accomplishments of the NREL in-house research effort involving polycrystalline thin-film tandems, as well as the research efforts under way in the subcontracted area.

  1. Physical Effects of Distributed PV Generation on California's Distribution System

    E-Print Network [OSTI]

    Cohen, Michael A

    2015-01-01

    Deployment of high-penetration photovoltaic (PV) power is expected to have a range of effects -- both positive and negative -- on the distribution grid. The magnitude of these effects may vary greatly depending upon feeder topology, climate, PV penetration level, and other factors. In this paper we present a simulation study of eight representative distribution feeders in three California climates at PV penetration levels up to 100\\%, supported by a unique database of distributed PV generation data that enables us to capture the impact of PV variability on feeder voltage and voltage regulating equipment. When comparing the influence of feeder location (i.e. climate) versus feeder type on outcomes, we find that location more strongly influences the incidence of reverse power flow, reductions in peak loading and the presence of voltage excursions. On the other hand, we find that feeder characteristics more strongly influence the magnitude of loss reduction and changes in voltage regulator operations. We find th...

  2. Annual Transportation Report for Radioactive Waste Shipments to and from the Nevada Test Site

    National Nuclear Security Administration (NNSA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefield Municipal GasAdministration Medal01 Sandia4) AugustA. Geographic Available for sale to the public

  3. FORM EIA-63B ANNUAL PHOTOVOLTAIC CELL/MODULE SHIPMENTS REPORT INSTRUCTIONS

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet) Wyoming Dry Natural GasNatural GasEIA lowers 2015Values shown for3 CELL/MODULE

  4. A Wavelet-Based Variability Model (WVM) for Solar PV Power Plants

    E-Print Network [OSTI]

    Lave, Matthew; Kleissl, Jan; Stein, Joshua S

    2013-01-01

    Model (WVM) for Solar PV Power Plants Matthew Lave, Jansolar photovoltaic (PV) power plant output given a singleproduce a simulated power plant output. The WVM is validated

  5. Analyzing and simulating the variability of solar irradiance and solar PV powerplants

    E-Print Network [OSTI]

    Lave, Matthew S.

    2012-01-01

    Models of diffuse solar radiation, Renew Energ, 33 (2008) [solar irradiance for analyzing areally- totalized PV systems, Sol Energsolar irradiance for analyzing areally- totalized PV systems, Sol Energ

  6. Utility Scale PV Perspective on SunShot Progress and Opportunities...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Utility Scale PV Perspective on SunShot Progress and Opportunities Utility Scale PV Perspective on SunShot Progress and Opportunities These slides correspond to a presentation...

  7. Linkage to Previous International PV Module QA Task Force Workshops; Proposal for Rating System (Presentation)

    SciTech Connect (OSTI)

    Kurtz, S.; Wohlgemuth, J.; Sample, T.; Yamamichi, M.; Kondo, M.

    2013-05-01

    This presentation gives the historical background of the creation of the International PV QA Task Force as an introduction to the PV Module Reliability Workshop.

  8. Pseudomonas syringae pv. syringae Uses Proteasome Inhibitor Syringolin A to Colonize from Wound Infection

    E-Print Network [OSTI]

    Pseudomonas syringae pv. syringae Uses Proteasome Inhibitor Syringolin A to Colonize from Wound syringae pv. syringae Uses Proteasome Inhibitor Syringolin A to Colonize from Wound Infection Sites. PLo

  9. DRAFT - DOE O 461.1C, Packaging and Transportation for Offsite Shipment of Materials of National Security Interest

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    The Order establishes requirements and responsibilities for ensuring the safety of packaging and transportation for offsite shipments of Materials of National Security Interest.

  10. Analytical Improvements in PV Degradation Rate Determination

    SciTech Connect (OSTI)

    Jordan, D. C.; Kurtz, S. R.

    2011-02-01

    As photovoltaic (PV) penetration of the power grid increases, it becomes vital to know how decreased power output may affect cost over time. In order to predict power delivery, the decline or degradation rates must be determined accurately. For non-spectrally corrected data several complete seasonal cycles (typically 3-5 years) are required to obtain reasonably accurate degradation rates. In a rapidly evolving industry such a time span is often unacceptable and the need exists to determine degradation rates accurately in a shorter period of time. Occurrence of outliers and data shifts are two examples of analytical problems leading to greater uncertainty and therefore to longer observation times. In this paper we compare three methodologies of data analysis for robustness in the presence of outliers, data shifts and shorter measurement time periods.

  11. Innovations in Wind and Solar PV Financing

    SciTech Connect (OSTI)

    Cory, K.; Coughlin, J.; Jenkin, T.; Pater, J.; Swezey, B.

    2008-02-01

    There is growing national interest in renewable energy development based on the economic, environmental, and security benefits that these resources provide. Historically, greater development of our domestic renewable energy resources has faced a number of hurdles, primarily related to cost, regulation, and financing. With the recent sustained increase in the costs and associated volatility of fossil fuels, the economics of renewable energy technologies have become increasingly attractive to investors, both large and small. As a result, new entrants are investing in renewable energy and new business models are emerging. This study surveys some of the current issues related to wind and solar photovoltaic (PV) energy project financing in the electric power industry, and identifies both barriers to and opportunities for increased investment.

  12. Kauai Island Utility Co-op (KIUC) PV integration study.

    SciTech Connect (OSTI)

    Ellis, Abraham; Mousseau, Tom

    2011-08-01

    This report investigates the effects that increased distributed photovoltaic (PV) generation would have on the Kauai Island Utility Co-op (KIUC) system operating requirements. The study focused on determining reserve requirements needed to mitigate the impact of PV variability on system frequency, and the impact on operating costs. Scenarios of 5-MW, 10-MW, and 15-MW nameplate capacity of PV generation plants distributed across the Kauai Island were considered in this study. The analysis required synthesis of the PV solar resource data and modeling of the KIUC system inertia. Based on the results, some findings and conclusions could be drawn, including that the selection of units identified as marginal resources that are used for load following will change; PV penetration will displace energy generated by existing conventional units, thus reducing overall fuel consumption; PV penetration at any deployment level is not likely to reduce system peak load; and increasing PV penetration has little effect on load-following reserves. The study was performed by EnerNex under contract from Sandia National Laboratories with cooperation from KIUC.

  13. Optimal Solar PV Arrays Integration for Distributed Generation

    SciTech Connect (OSTI)

    Omitaomu, Olufemi A; Li, Xueping

    2012-01-01

    Solar photovoltaic (PV) systems hold great potential for distributed energy generation by installing PV panels on rooftops of residential and commercial buildings. Yet challenges arise along with the variability and non-dispatchability of the PV systems that affect the stability of the grid and the economics of the PV system. This paper investigates the integration of PV arrays for distributed generation applications by identifying a combination of buildings that will maximize solar energy output and minimize system variability. Particularly, we propose mean-variance optimization models to choose suitable rooftops for PV integration based on Markowitz mean-variance portfolio selection model. We further introduce quantity and cardinality constraints to result in a mixed integer quadratic programming problem. Case studies based on real data are presented. An efficient frontier is obtained for sample data that allows decision makers to choose a desired solar energy generation level with a comfortable variability tolerance level. Sensitivity analysis is conducted to show the tradeoffs between solar PV energy generation potential and variability.

  14. 3-Port Single-Stage PV & Battery Converter Improves Efficiency and Cost in Combined PV/Battery Systems

    SciTech Connect (OSTI)

    Bundschuh, Paul

    2013-03-23

    Due to impressive cost reductions in recent years, photovoltaic (PV) generation is now able to produce electricity at highly competitive prices, but PV’s inherent intermittency reduces the potential value of this energy. The integration of battery storage with PV will be transformational by increasing the value of solar. Utility scale systems will benefit by firming intermittency including PV ramp smoothing, grid support and load shifting, allowing PV to compete directly with conventional generation. For distributed grid-tied PV adding storage will reduce peak demand utility charges, as well as providing backup power during power grid failures. The largest long term impact of combined PV and battery systems may be for delivering reliable off-grid power to the billions of individuals globally without access to conventional power grids, or for billions more that suffer from daily power outages. PV module costs no longer dominate installed PV system costs. Balance-of-System (BOS) costs including the PV inverter and installation now contribute the majority of installed system costs. Battery costs are also dropping faster than installation and battery power converter systems. In each of these separate systems power converters have become a bottleneck for efficiency, cost and reliability. These bottlenecks are compounded in hybrid power conversion systems that combine separate PV and battery converters. Hybrid power conversion systems have required multiple power converters hardware units and multiple power conversion steps adding to efficiency losses, product and installation costs, and reliability issues. Ideal Power Converters has developed and patented a completely new theory of operation for electronic power converters using its indirect EnergyPacket Switching™ topology. It has established successful power converter products for both PV and battery systems, and its 3-Port Hybrid Converter is the first product to exploit the topology’s capability for the industry’s first single-stage multi-port hybrid power converter. This unique low cost approach eliminates the hybrid power conversion bottlenecks when integrating batteries into PV systems. As result this product will significantly accelerate market adoption of these systems.

  15. Air Shipment of Highly Enriched Uranium Spent Nuclear Fuel from Romania

    SciTech Connect (OSTI)

    K. J. Allen; I. Bolshinsky; L. L. Biro; M. E. Budu; N. V. Zamfir; M. Dragusin

    2010-07-01

    Romania safely air shipped 23.7 kilograms of Russian origin highly enriched uranium (HEU) spent nuclear fuel from the VVR S research reactor at Magurele, Romania, to the Russian Federation in June 2009. This was the world’s first air shipment of spent nuclear fuel transported in a Type B(U) cask under existing international laws without special exceptions for the air transport licenses. This shipment was coordinated by the Russian Research Reactor Fuel Return Program (RRRFR), part of the U.S. Department of Energy Global Threat Reduction Initiative (GTRI), in cooperation with the Romania National Commission for Nuclear Activities Control (CNCAN), the Horia Hulubei National Institute of Physics and Nuclear Engineering (IFIN-HH), and the Russian Federation State Corporation Rosatom. The shipment was transported by truck to and from the respective commercial airports in Romania and the Russian Federation and stored at a secure nuclear facility in Russia where it will be converted into low enriched uranium. With this shipment, Romania became the 3rd country under the RRRFR program and the 14th country under the GTRI program to remove all HEU. This paper describes the work, equipment, and approvals that were required to complete this spent fuel air shipment.

  16. Research Reactor Preparations for the Air Shipment of Highly Enriched Uranium from Romania

    SciTech Connect (OSTI)

    K. J. Allen; I. Bolshinsky; L. L. Biro; M. E. Budu; N. V. Zamfir; M. Dragusin; C. Paunoiu; M. Ciocanescu

    2010-03-01

    In June 2009 two air shipments transported both unirradiated (fresh) and irradiated (spent) Russian-origin highly enriched uranium (HEU) nuclear fuel from two research reactors in Romania to the Russian Federation for conversion to low enriched uranium. The Institute for Nuclear Research at Pitesti (SCN Pitesti) shipped 30.1 kg of HEU fresh fuel pellets to Dimitrovgrad, Russia and the Horia Hulubei National Institute of Physics and Nuclear Engineering (IFIN-HH) shipped 23.7 kilograms of HEU spent fuel assemblies from the VVR S research reactor at Magurele, Romania, to Chelyabinsk, Russia. Both HEU shipments were coordinated by the Russian Research Reactor Fuel Return Program (RRRFR) as part of the U.S. Department of Energy Global Threat Reduction Initiative (GTRI), were managed in Romania by the National Commission for Nuclear Activities Control (CNCAN), and were conducted in cooperation with the Russian Federation State Corporation Rosatom and the International Atomic Energy Agency. Both shipments were transported by truck to and from respective commercial airports in Romania and the Russian Federation and stored at secure nuclear facilities in Russia until the material is converted into low enriched uranium. These shipments resulted in Romania becoming the 3rd country under the RRRFR program and the 14th country under the GTRI program to remove all HEU. This paper describes the research reactor preparations and license approvals that were necessary to safely and securely complete these air shipments of nuclear fuel.

  17. PV Validation and Bankability Workshop: San Jose, California

    SciTech Connect (OSTI)

    Granata, J.; Howard, J.

    2011-12-01

    This report is a collaboration between Sandia National Laboratories, the National Renewable Energy Laboratory, and the Florida Solar Energy Center (FSEC). The report provides feedback from the U.S. Department of Energy's (DOE) Solar Program PV Validation and Bankability Workshop in San Jose, California on August 31, 2011. It focuses on the current state of PV in the United States, private funding to fund U.S. PV industry growth, roles and functions of the regional test center program, and ways to improve the current validation and bankability practices.

  18. ENERGY-10 PV: Photovoltaics, A New Capability (Preprint)

    SciTech Connect (OSTI)

    Balcomb, J.D.; Hayter, S.J.; Weaver, N.L.

    2001-02-16

    This is one of two companion papers that describe the ENERGY-10 PV design-tool computer simulation program. The other paper is titled ''Hourly Simulation of Grid-Connected PV Systems Using Realistic Building Loads.'' While this paper focuses on the implementation method, the companion paper focuses on the PV aspects of the program. The case study in this paper is a residential building application, whereas the case study in the companion paper is a commercial application with an entirely different building load characteristic. Together, they provide a balanced view.

  19. Identifying Critical Pathways to High-Performance PV: Preprint

    SciTech Connect (OSTI)

    Symko-Davies, M.; Noufi, R.; Kurtz, S.

    2002-05-01

    This conference paper describes the High-Performance Photovoltaic (HiPerf PV)Project was initiated by the U.S. Department of Energy to substantially increase the viability of photovoltaics (PV) for cost-competitive applications so that PV can contribute significantly to our energy supply and our environment in the 21st century. To accomplish this, the NCPV directs in-house and subcontracted research in high-performance polycrystalline thin-film and multijunction concentrator devices. Details of the subcontractor and in-house progress will be described toward identifying critical pathways of 25% polycrystalline thin-film tandem cells and developing multijunction concentrator modules to 33%.

  20. 66 IAEI NEWS September.October 2004 www.iaei.org PERSPECTIVES ON PV

    E-Print Network [OSTI]

    Johnson, Eric E.

    66 IAEI NEWS September.October 2004 www.iaei.org PERSPECTIVES ON PV A t first glance, the obvious answer is: Photovol- taic (PV) systems are no different from other electrical power systems critical is grounding PV systems? Let us examine the various features of PV systems that relate

  1. 80 IAEI NEWS May . June 2012 www.iaei.org Microinverters and ac Pv Modules

    E-Print Network [OSTI]

    Johnson, Eric E.

    80 IAEI NEWS May . June 2012 www.iaei.org Microinverters and ac Pv Modules M icroinverters and AC PV modules are becom- ing very common in residential and small commercial PV systems. See photos 1 and 2. They have even been used in PV systems rated at 60 kW and above. They have some common features

  2. 28 IAEI NEWS May.June 2005 www.iaei.org PERSPECTIVES ON PV

    E-Print Network [OSTI]

    Johnson, Eric E.

    28 IAEI NEWS May.June 2005 www.iaei.org PERSPECTIVES ON PV #12;www.iaei.org May.June 2005 IAEI NEWS 29 PERSPECTIVES ON PV I nspectors are more and more frequently faced with permitting or inspecting PV-qualified people are installing many excellent, code-compliant PV systems, others are designing and installing

  3. 18 IAEI NEWS November.December 2004 www.iaei.org PERSPECTIVES ON PV

    E-Print Network [OSTI]

    Johnson, Eric E.

    18 IAEI NEWS November.December 2004 www.iaei.org PERSPECTIVES ON PV Photo 1. Framed PV modules A series of articles on photovoltaic (PV) power systems and the National Electrical Code by John Wiles Stalking the Elusive and Somewhat Strange PV System #12;www.iaei.org November.December 2004 IAEI NEWS 19

  4. Robust control strategy for PV system integration in distribution systems M.J. Hossain a,

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Robust control strategy for PV system integration in distribution systems M.J. Hossain a, , T t s " Robust control provides flexible photovoltaic (PV) accommodations. " A robust PV control can significantly enhance the penetration level. " The change in volatile PV generations is considered

  5. 12 IAEI NEWS July.August 2004 www.iaei.org PERSPECTIVES ON PV

    E-Print Network [OSTI]

    Johnson, Eric E.

    12 IAEI NEWS July.August 2004 www.iaei.org PERSPECTIVES ON PV A series of articles on photovoltaic (PV) power systems and the National Electrical Code Single Conductor Exposed Cables! Not In My or commercial PV installation. Yes, PV systems have some unusual wiring meth- ods allowed by the Code. However

  6. PV i Undervisningen EFP 33033-0174 Version 02 2 PA Energy A/S

    E-Print Network [OSTI]

    PV i Undervisningen EFP 33033-0174 Version 02 2 PA Energy A/S Bilag 7.6 European Survey of PV Education and Training #12;PV i Undervisningen EFP 33033-0174 Version 02 3 PA Energy A/S European Survey of PV Education and Training Med den voksende interesse for og relevans af vedvarende

  7. Do PV Systems Increase Residential Selling Prices If So, How Can Practitioners Estimate This Increase?

    E-Print Network [OSTI]

    Hoen, Ben

    2013-01-01

    of Photovoltaic Energy Systems on Residential Selling Pricesof photovoltaic (PV) energy systems on home sales prices.

  8. CREATING DYNAMIC EQUIVALENT PV CIRCUIT MODELS WITH IMPEDANCE SPECTROSCOPY FOR ARC FAULT MODELING

    E-Print Network [OSTI]

    CREATING DYNAMIC EQUIVALENT PV CIRCUIT MODELS WITH IMPEDANCE SPECTROSCOPY FOR ARC FAULT MODELING ® (NEC® ) requires new photovoltaic (PV) systems on or penetrating a building to include a listed arc of the arcing frequencies through PV components despite the potential for modules and other PV components

  9. Modeling and Simulation of Solar PV Arrays under Changing Illumination Conditions

    E-Print Network [OSTI]

    Lehman, Brad

    Modeling and Simulation of Solar PV Arrays under Changing Illumination Conditions Dzung D Nguyen shadows (a passing cloud) on the output power of solar PV arrays. Each solar array is composed of a matrix of a shaded solar PV array as well as the PV output power. The model is also able to simulate and compute

  10. PV-PPV: Parameter Variability Aware, Automatically Extracted, Nonlinear Time-Shifted Oscillator Macromodels

    E-Print Network [OSTI]

    Roychowdhury, Jaijeet

    Impact of residential PV adoption on Retail Electricity Rates Desmond W.H. Cai a,n , Sachin Adlakha of Technology, 1200 E. California Blvd., Pasadena, CA 91106, USA H I G H L I G H T S Households who install PV to adopt PV. We find that this feedback has significant impact on PV uptake only in later years. Utility

  11. Multiple Jets as PV Staircases: The Phillips Effect and the Resilience of Eddy-Transport Barriers

    E-Print Network [OSTI]

    Cambridge, University of

    Multiple Jets as PV Staircases: The Phillips Effect and the Resilience of Eddy-Transport Barriers D 2007) ABSTRACT A review is given that focuses on why the sideways mixing of potential vorticity (PV. PV mixing often produces a sideways layering or banding of the PV distribution and therefore

  12. Parametric Study of PV Arc-Fault Generation Methods and Analysis of Conducted DC Spectrum

    E-Print Network [OSTI]

    Parametric Study of PV Arc-Fault Generation Methods and Analysis of Conducted DC Spectrum Jay photovoltaic (PV) direct current (DC) arc- fault detectors use the frequency content of the PV system to detect by different PV arcs in the field. In this investigation, we (a) discuss the differences in establishing

  13. PV Derived Data for Predicting Performance; NREL (National Renewable Energy Laboratory)

    SciTech Connect (OSTI)

    Marion, Bill

    2015-09-14

    A method is described for providing solar irradiance data for modeling PV performance by using measured PV performance data and back-solving for the unknown direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI), which can then be used to model the performance of PV systems of any size, PV array tilt, or PV array azimuth orientation. Ideally situated for using the performance data from PV modules with micro-inverters, the PV module operating current is used to determine the global tilted irradiance (GTI), and a separation model is then used to determine the DNI and DHI from the GTI.

  14. Interconnecting PV on New York City's Secondary Network Distribution System

    SciTech Connect (OSTI)

    Anderson, K.; Coddington, M.; Burman, K.; Hayter, S.; Kroposki, B.; Watson, A.

    2009-12-01

    This study describes technical assistance provided by NREL to help New York City and Con Edison improve the interconnection of distributed PV systems on a secondary network distribution system.

  15. Full Steam Ahead for PV in US Homes?

    SciTech Connect (OSTI)

    Bolinger, Mark A; Barbose, Galen; Wiser, Ryan

    2009-01-15

    In October 2008, the United States Congress extended both the residential and commercial solar investment tax credits (ITCs) for an unprecedented eight years, lifted the $2,000 cap on the residential credit, removed the prohibition on utility use of the commercial credit, and eliminated restrictions on the use of both credits in conjunction with the Alternative Minimum Tax. These significant changes, which apply to systems placed in service on or after January 1, 2009, will increase the value of the solar credits for residential system owners in particular, and are likely--in conjunction with state, local, and utility rebate programs targeting solar--to spur significant growth in residential, commercial, and utility-scale photovoltaic (PV) installations in the years ahead. This article focuses specifically on the residential credit, describing three areas in which removal of the $2,000 cap on the residential ITC will have significant implications for PV rebate program administrators, PV system owners, and the PV industry.

  16. Instrumentation for Evaluating PV System Performance Losses from Snow

    SciTech Connect (OSTI)

    Marion, B.; Rodriguez, J.; Pruett, J.

    2009-01-01

    When designing a photovoltaic (PV) system for northern climates, the prospective installation should be evaluated with respect to the potentially detrimental effects of snow preventing solar radiation from reaching the PV cells. The extent to which snow impacts performance is difficult to determine because snow events also increase the uncertainty of the solar radiation measurement, and the presence of snow needs to be distinguished from other events that can affect performance. This paper describes two instruments useful for evaluating PV system performance losses from the presence of snow: (1) a pyranometer with a heater to prevent buildup of ice and snow, and (2) a digital camera for remote retrieval of images to determine the presence of snow on the PV array.

  17. AEP SWEPCO - SMART Source Solar PV Program | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Amount Residential: 1.50watt DC Non-residential: 1.20watt DC Provider Smart Source PV Program Southwestern Electric Power Company (SWEPCO) offers rebates to customers that...

  18. Giant Leap Forward Toward Quality Assurance of PV Modules (Presentation)

    SciTech Connect (OSTI)

    Kurtz, S.; Wohlgemuth, J.; Sample, T.; Yamamichi, M.

    2012-03-01

    The presentation describes the composition of and motivation for the International PV QA Task Force, then describes the presentations and discussion that occurred at the workshop on Feb. 29th, 2012.

  19. Integrating Solar PV into Energy Services Performance Contracts...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    can use performance contracts to finance the purchase of a commercial-scale rooftop PV system with limited to no upfront cost, and a series of suggested best practices for...

  20. Interconnecting PV on New York City's Secondary Network Distribution System

    SciTech Connect (OSTI)

    K. Anderson; M. Coddington; K. Burman; S. Hayter; B. Kroposki; and A. Watson

    2009-11-30

    The U.S. Department of Energy (DOE) has teamed with cities across the country through the Solar America Cities (SAC) partnership program to help reduce barriers and accelerate implementation of solar energy. The New York City SAC team is a partnership between the City University of New York (CUNY), the New York City Mayor s Office of Long-term Planning and Sustainability, and the New York City Economic Development Corporation (NYCEDC).The New York City SAC team is working with DOE s National Renewable Energy Laboratory (NREL) and Con Edison, the local utility, to develop a roadmap for photovoltaic (PV) installations in the five boroughs. The city set a goal to increase its installed PV capacity from1.1 MW in 2005 to 8.1 MW by 2015 (the maximum allowed in 2005). A key barrier to reaching this goal, however, is the complexity of the interconnection process with the local utility. Unique challenges are associated with connecting distributed PV systems to secondary network distribution systems (simplified to ���¢��������networks���¢������� in this report). Although most areas of the country use simpler radial distribution systems to distribute electricity, larger metropolitan areas like New York City typically use networks to increase reliability in large load centers. Unlike the radial distribution system, where each customer receives power through a single line, a network uses a grid of interconnected lines to deliver power to each customer through several parallel circuits and sources. This redundancy improves reliability, but it also requires more complicated coordination and protection schemes that can be disrupted by energy exported from distributed PV systems. Currently, Con Edison studies each potential PV system in New York City to evaluate the system s impact on the network, but this is time consuming for utility engineers and may delay the customer s project or add cost for larger installations. City leaders would like to streamline this process to facilitate faster, simpler, and less expensive distributed PV system interconnections. To assess ways to improve the interconnection process, NREL conducted a four-part study with support from DOE. The NREL team then compiled the final reports from each study into this report. In Section 1���¢��������PV Deployment Analysis for New York City���¢��������we analyze the technical potential for rooftop PV systems in the city. This analysis evaluates potential PV power production in ten Con Edison networks of various locations and building densities (ranging from high density apartments to lower density single family homes). Next, we compare the potential power production to network loads to determine where and when PV generation is most likely to exceed network load and disrupt network protection schemes. The results of this analysis may assist Con Edison in evaluating future PV interconnection applications and in planning future network protection system upgrades. This analysis may also assist other utilities interconnecting PV systems to networks by defining a method for assessing the technical potential of PV in the network and its impact on network loads. Section 2���¢��������A Briefing for Policy Makers on Connecting PV to a Network Grid���¢��������presents an overview intended for nontechnical stakeholders. This section describes the issues associated with interconnecting PV systems to networks, along with possible solutions. Section 3���¢��������Technical Review of Concerns and Solutions to PV Interconnection in New Y

  1. Taunton Municipal Lighting Plant- Residential PV Rebate Program

    Office of Energy Efficiency and Renewable Energy (EERE)

    Customers of Taunton Municipal Lighting Plant (TMLP) may be eligible for a $1.50/watt rebate on solar photovoltaic (PV) installations, up to a maximum rebate of $4,500. The system must be installed...

  2. Loan Guarantees for Three California PV Solar Plants Expected...

    Broader source: Energy.gov (indexed) [DOE]

    Tempe, Arizona, is sponsoring all three projects and will supply them with Cd-Te thin film solar PV modules -- also known as solar panels -- from a new Mesa, Arizona,...

  3. DOE-LPO-MiniReport_PV_v10

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    fastest growing sector of the solar industry. Today, utility-scale PV solar has the capacity to produce more than 8,100 MW of electricity - which is enough clean energy to power...

  4. Tucson's Solar Experience: Developing PV with RFPs and PPAs

    Office of Energy Efficiency and Renewable Energy (EERE)

    This presentation was given January 15, 2013, by Bruce Plenk, Solar Coordinator for the City of Tucson, Arizona, as part of the CommRE Developing PV Projects With RFPs and PPAs webinar.

  5. Plug and Play Solar PV for American Homes

    Office of Energy Efficiency and Renewable Energy (EERE)

    The Fraunhofer Center for Sustainable Energy Systems (CSE) will develop a new plug-and-play PV system that self-checks for proper installation and safety and communicates with the local utility and...

  6. Economic Analysis of a Brackish Water Photovoltaic-Operated (BWRO-PV) Desalination System: Preprint

    SciTech Connect (OSTI)

    Al-Karaghouli, A.; Kazmerski, L. L.

    2010-10-01

    The photovoltaic (PV)-powered reverse-osmosis (RO) desalination system is considered one of the most promising technologies in producing fresh water from both brackish and sea water, especially for small systems located in remote areas. We analyze the economic viability of a small PV-operated RO system with a capacity of 5 m3/day used to desalinate brackish water of 4000 ppm total dissolve solids, which is proposed to be installed in a remote area of the Babylon governorate in the middle of Iraq; this area possesses excellent insolation throughout the year. Our analysis predicts very good economic and environmental benefits of using this system. The lowest cost of fresh water achieved from using this system is US $3.98/ m3, which is very reasonable compared with the water cost reported by small-sized desalination plants installed in rural areas in other parts of the world. Our analysis shows that using this small system will prevent the release annually of 8,170 kg of CO2, 20.2 kg of CO, 2.23 kg of CH, 1.52 kg of particulate matter, 16.41 kg of SO2, and 180 kg of NOx.

  7. Time-dependent first-principles approaches to PV materials

    SciTech Connect (OSTI)

    Miyamoto, Yoshiyuki

    2013-12-10

    Computational scheme for designing photovoltaic (PV) materials is presented. First-principles electron dynamics of photo-excitation and subsequent electron-hole splitting is performed based on the time-dependent density functional theory. Photo-induced enhancement of dipole moment was observed in a polar crystal and a donor-acceptor molecular pair. These experiences will pave a way to design PV material from first-principles simulations.

  8. Microgrid-Ready Solar PV; NREL (National Renewable Energy Laboratory)

    SciTech Connect (OSTI)

    2015-07-01

    Designing new solar projects to be 'microgrid-ready' enables the U.S. DoD, other federal agencies, and the private sector to plan future microgrid initiatives to utilize solar PV as a generating resource. This fact sheet provides background information with suggested language for several up-front considerations that can be added to a solar project procurement or request for proposal (RFP) that will help ensure that PV systems are built for future microgrid connection.

  9. Public information circular for shipments of irradiated reactor fuel. Revision 9

    SciTech Connect (OSTI)

    Not Available

    1993-03-01

    This circular has been prepared to provide information on the shipment of irradiated reactor fuel (spent fuel) subject to regulation by the Nuclear Regulatory Commission (NRC), and to meet the requirements of Public Law 96--295. The report provides a brief description of NRC authority for certain aspects of transporting spent fuel. It provides descriptive statistics on spent fuel shipments regulated by the NRC from 1979 to 1992. It also lists detailed highway and railway segments used within each state from October 1, 1987 through December 31, 1992.

  10. Continuing Developments in PV Risk Management: Strategies, Solutions, and Implications

    SciTech Connect (OSTI)

    Lowder, T.; Mendelsohn, M.; Speer, B.; Hill, R.

    2013-02-01

    As the PV industry matures, successful risk management practices will become more imperative to ensure investor confidence, control costs, and facilitate further growth. This report discusses several key aspects of risk management during the commercial- and utility-scale project life cycle, from identification of risks, to the process of mitigating and allocating those risks among project parties, to transferring those risks through insurance. The report also explores novel techniques in PV risk management, options to offload risks onto the capital markets, and innovative insurance policies (namely warranty policies) that address risks unique to the PV sector. One of the major justifications for robust risk management in the PV industry is the cost-reduction opportunities it affords. If the PV industry can demonstrate the capability to successfully manage its risks, thereby inspiring confidence in financiers, it may be able to obtain a lower cost of capital in future transactions. A lower cost of capital translates to a lower cost of energy, which will in turn enhance PV?s competitiveness at a time when it will have to rely less on subsidies to support its market penetration.

  11. How Can We Make PV Modules Safer?: Preprint

    SciTech Connect (OSTI)

    Wohlgemuth, J. H.; Kurtz, S. R.

    2012-06-01

    Safety is a prime concern for the photovoltaics (PV) industry. As a technology deployed on residential and commercial buildings, it is critical that PV not cause damage to the buildings nor harm the occupants. Many of the PV systems on buildings are of sufficiently high voltage (300 to 600 Volts dc) that they may present potential hazards. These PV systems must be safe in terms of mechanical damage (nothing falls on someone), shock hazard (no risk of electrical shock when touching an exposed circuit element), and fire (the modules neither cause nor promote a fire). The present safety standards (IEC 61730 and UL 1703) do a good job of providing for design rules and test requirements for mechanical, shock, and spread of flame dangers. However, neither standard addresses the issue of electrical arcing within a module that can cause a fire. To make PV modules, they must be designed, built, and installed with an emphasis on minimizing the potential for open circuits and ground faults. This paper provides recommendations on redundant connection designs, robust mounting methods, and changes to the safety standards to yield safer PV modules.

  12. Lightweight PV Inverters: Dual Bi-Directional IGBTs Modules Enables Breakthrough PV Inverter Using Current Modulation Topology

    SciTech Connect (OSTI)

    2012-01-30

    Solar ADEPT Project: PV inverters convert DC power generated by modules into usable AC power. IPC’s initial 30kW 94lb. PV inverter reduces the weight of comparable 30kW PV inverters by 90%—reducing the cost of materials, manufacturing, shipping, and installation. With ARPA-E support, new bi-directional silicon power switches will be developed, commercialized, and utilized in IPC’s next-generation PV inverter. With these components, IPC will produce 100kW inverters that weight less than 100lb., reducing the weight of conventional 3,000lb. 100kW inverters by more than 95%. The new power switches will cut IPC’s $/W manufacturing cost in half, as well as further reduce indirect shipping and installation costs.

  13. The Present, Mid-Term, and Long-Term Supply Curves for Tellurium; and Updates in the Results from NREL's CdTe PV Module Manufacturing Cost Model (Presentation)

    SciTech Connect (OSTI)

    Woodhouse, M.; Goodrich, A.; Redlinger, M.; Lokanc, M.; Eggert, R.

    2013-09-01

    For those PV technologies that rely upon Te, In, and Ga, first-order observations and calculations hint that there may be resource constraints that could inhibit their successful deployment at a SunShot level. These are only first-order approximations, however, and the possibility for an expansion in global Te, In, and Ga supplies needs to be considered in the event that there are upward revisions in their demand and prices.In this study, we examine the current, mid-term, and long-term prospects of Tellurium (Te) for use in PV. We find that the current global supply base of Te would support <10 GW of annual traditional CdTe PV manufacturing production. But as for the possibility that the supply base for Te might be expanded, after compiling several preliminary cumulative availability curves we find that there may be significant upside potential in the supply base for this element - principally vis a vis increasing demand and higher prices. Primarily by reducing the Tellurium intensity in manufacturing and by increasing the recovery efficiency of Te in Cu refining processes, we calculate that it may prove affordable to PV manufacturers to expand the supply base for Te such that 100 GW, or greater, of annual CdTe PV production is possible in the 2030 - 2050 timeframe.

  14. Flat Plate PV Module Eligibility Listing Procedure Updated 6/2/14 Senate Bill 1 (SB1) defines the solar incentive programs for California, and flat plate PV

    E-Print Network [OSTI]

    Flat Plate PV Module Eligibility Listing Procedure Updated 6/2/14 Senate Bill 1 (SB1) defines the solar incentive programs for California, and flat plate PV modules 1 must be listed on the SB1 for adding PV modules to the SB1 list is as follows: 1 . Data submitted to the Energy Commission

  15. Radioactive materials released from nuclear power plants. Volume 11: Annual report, 1990

    SciTech Connect (OSTI)

    Tichler, J.; Doty, K.; Congemi, J. [Brookhaven National Lab., Upton, NY (United States)

    1993-10-01

    Releases of radioactive materials in airborne and liquid effluents from commercial light water reactors during 1990 have been compiled and reported. Data on solid waste shipments as well as selected operating information have been included. This report supplements earlier annual reports issued by the former Atomic Energy Commission and the Nuclear Regulatory Commission. The 1990 release data are summarized in tabular form. Data covering specific radionuclides are summarized.

  16. Transportation impact analysis for the shipment of low specific activity nitric acid. Revisison 1

    SciTech Connect (OSTI)

    Green, J.R.

    1995-05-16

    This is in support of the Plutonium-Uranium Extraction (PUREX) Facility Low Specific Activity (LSA) Nitric Acid Shipment Environmental Assessment. It analyzes potential toxicological and radiological risks associated with transportation of PUREX Facility LSA Nitric Acid from the Hanford Site to Portsmouth VA, Baltimore MD, and Port Elizabeth NJ.

  17. United States Home Information Center | Customer Support | Site Map Track Shipments

    E-Print Network [OSTI]

    Bartholdi III, John J.

    United States Home Information Center | Customer Support | Site Map Search Track Shipments Detailed your detailed tracking results (optional) Enter your email, submit up to three email addresses | Service Info | About FedEx | Investor Relations | Careers | fedex.com Terms of Use | Privacy Policy

  18. United States Home Information Center | Customer Support | Site Map Track Shipments

    E-Print Network [OSTI]

    Bartholdi III, John J.

    United States Home Information Center | Customer Support | Site Map Search Track Shipments Detailed results (optional) Enter your email, submit up to three email addresses (separated by commas), add yourEx | Investor Relations | Careers | fedex.com Terms of Use | Privacy Policy This site is protected by copyright

  19. Rice Snl6, a cinnamoyl-CoA reductase-like gene family member, is required for NH1-mediated immunity to Xanthomonas oryzae pv. oryzae.

    E-Print Network [OSTI]

    Bart, Rebecca S; Chern, Mawsheng; Vega-Sánchez, Miguel E; Canlas, Patrick; Ronald, Pamela C

    2010-01-01

    Immunity to Xanthomonas oryzae pv. oryzae Rebecca S. Bartpathogen, Xanthomonas oryzae pv. oryzae (Xoo), constitutiveagainst Xanthomonas oryzae pv. oryzae in Rice. Molecular

  20. The Xanthomonas oryzae pv. oryzae PhoPQ two-component system is required for AvrXA21 activity, hrpG expression, and virulence.

    E-Print Network [OSTI]

    2008-01-01

    against Xanthomonas oryzae pv. oryzae in Korea. Kor. J.the Xanthomonas campestris pv. campestris lipopolysaccharidein Xanthomonas oryzae pv. oryzae re- quired for AvrXa21

  1. PV Cell and Module Calibration Activities at NREL

    SciTech Connect (OSTI)

    Emery, K.; Anderberg, A.; Kiehl, J.; Mack, C.; Moriarty, T.; Ottoson, L.; Rummel, S.

    2005-11-01

    The performance of PV cells and modules with respect to standard reference conditions is a key indicator of progress of a given technology. This task provides the U.S. terrestrial PV community with the most accurate measurements that are technically possible in a timely fashion. The international module certification and accreditation program PVGap requires certification laboratories to maintain their calibration traceability path to groups like this one. The politics of a "world record" efficiency requires that an independent laboratory perform these measurements for credibility. Most manufacturers base their module peak watt rating upon standards and reference cells calibrated under this task. This task has been involved in reconciling disputes between manufacturers and their cell suppliers in terms of expected versus actual performance. This task has also served as a resource to the PV community for consultation on solar simulation, current versus voltage measurement instrumentation, measurement procedures and measurement artifacts.

  2. Recent developments in high-efficiency PV cells

    SciTech Connect (OSTI)

    Deb, S.

    2000-05-22

    Enormous progress has been made in recent years on a number of photovoltaic (PV) materials and devices in terms of conversion efficiencies. Ultrahigh-efficiency (>30{percent}) PV cells have been fabricated from gallium arsenide (GaAs) and its ternary alloys such as gallium indium phosphide (GaInP{sub 2}). The high-efficiency GaAs-based solar cells are being produced on a commercial scale, particularly for space applications. Efficiencies in the range of 18{percent} to 24{percent} have been achieved in traditional silicon-based devices fabricated from both multicrystalline and single-crystal materials. Major advances in efficiency have also been made on various thin-film solar cells based on amorphous silicon (aSi:H), copper gallium indium diselenide (CIGS), and cadmium telluride materials. This paper gives a brief overview of the recent progress in PV cell efficiencies based on these materials and devices.

  3. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim R.

    2012-01-01

    would be the least-cost option, across PV-to-load ratios,the overall cost-effectiveness of distributed PV for anthe value or cost-effectiveness of distributed PV from the

  4. Encouraging PV Adoption in New Market-Rate Residential Construction: A Critical Review of Program Experiences to Date

    E-Print Network [OSTI]

    Barbose, Galen; Wiser, Ryan; Bolinger, Mark

    2006-01-01

    retrofits. The higher cost of PV on individual or smallcan easily roll the cost of the PV system into theiral. analyzed project cost data for PV systems funded through

  5. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim R.

    2012-01-01

    greater support for PV adoption among high usage customers.customer adoption of distributed photovoltaics (PV), but hasadoption. In the long-run, however, large differences in the compensation provided for distributed PV

  6. Marker-exchange mutagenesis and complementation strategies for the Gram-negative bacteria Xanthomonas oryzae pv. oryzae.

    E-Print Network [OSTI]

    Lee, Sang-Won; Ronald, P C

    2006-01-01

    of a Xanthomonas oryzae pv. oryzae flagellar operon region2002) The Xanthomonas oryzae pv. lozengeoryzae raxP and raxQsystem in xanthomonas oryzae pv. oryzae required for AvrXa21

  7. Designing PV Incentive Programs to Promote Performance: A Review of Current Practice in the U.S.

    E-Print Network [OSTI]

    Barbose, Galen; Wiser, Ryan; Bolinger, Mark

    2008-01-01

    with Large-scale Implementation of Domestic PV Systems andwith Large PV Systems on Buildings in Japan. Progress inPerformance of Grid-connected PV Systems on Buildings in

  8. Metabolomic and transcriptomic analysis of the rice response to the bacterial blight pathogen Xanthomonas oryzae pv. oryzae.

    E-Print Network [OSTI]

    2010-01-01

    system in Xanthomonas oryzae pv. oryzae required for AvrXa212002). The Xanthomonas oryzae pv. lozengeoryzae raxP andPf1 against Xanthomo- nas oryzae pv. oryzae in rice leaves.

  9. Encouraging PV Adoption in New Market-Rate Residential Construction: A Critical Review of Program Experiences to Date

    E-Print Network [OSTI]

    Barbose, Galen; Wiser, Ryan; Bolinger, Mark

    2006-01-01

    ENCOURAGING PV ADOPTION IN NEW MARKET-RATE RESIDENTIALdeployment of photovoltaics (PV) in new, market-rate homes,the new home market for PV. feature in new developments

  10. Metabolomic and transcriptomic analysis of the rice response to the bacterial blight pathogen Xanthomonas oryzae pv. oryzae

    E-Print Network [OSTI]

    2010-01-01

    system in Xanthomonas oryzae pv. oryzae required for AvrXa212002). The Xanthomonas oryzae pv. lozengeoryzae raxP andPf1 against Xanthomo- nas oryzae pv. oryzae in rice leaves.

  11. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim R.

    2012-01-01

    Rate Structures on Real PV Systems. Preprint, Nationaland the Economics of Solar PV: Could Mandatory Time- of-UsePricing Beneficial to Solar PV in New York City? Prepared

  12. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim

    2010-01-01

    Rate Structures on Real PV Systems. NREL/CP-670-42923.Pricing Beneficial to Solar PV in New York City? PreparedSubstantial Benefit of Solar PV. ” The Electricity Journal,

  13. Time series power flow analysis for distribution connected PV generation.

    SciTech Connect (OSTI)

    Broderick, Robert Joseph; Quiroz, Jimmy Edward; Ellis, Abraham; Reno, Matthew J.; Smith, Jeff; Dugan, Roger

    2013-01-01

    Distributed photovoltaic (PV) projects must go through an interconnection study process before connecting to the distribution grid. These studies are intended to identify the likely impacts and mitigation alternatives. In the majority of the cases, system impacts can be ruled out or mitigation can be identified without an involved study, through a screening process or a simple supplemental review study. For some proposed projects, expensive and time-consuming interconnection studies are required. The challenges to performing the studies are twofold. First, every study scenario is potentially unique, as the studies are often highly specific to the amount of PV generation capacity that varies greatly from feeder to feeder and is often unevenly distributed along the same feeder. This can cause location-specific impacts and mitigations. The second challenge is the inherent variability in PV power output which can interact with feeder operation in complex ways, by affecting the operation of voltage regulation and protection devices. The typical simulation tools and methods in use today for distribution system planning are often not adequate to accurately assess these potential impacts. This report demonstrates how quasi-static time series (QSTS) simulation and high time-resolution data can be used to assess the potential impacts in a more comprehensive manner. The QSTS simulations are applied to a set of sample feeders with high PV deployment to illustrate the usefulness of the approach. The report describes methods that can help determine how PV affects distribution system operations. The simulation results are focused on enhancing the understanding of the underlying technical issues. The examples also highlight the steps needed to perform QSTS simulation and describe the data needed to drive the simulations. The goal of this report is to make the methodology of time series power flow analysis readily accessible to utilities and others responsible for evaluating potential PV impacts.

  14. Testing of Packaging Materials for Improved PV Module Reliability

    SciTech Connect (OSTI)

    Jorgensen, G. J.; Terwilliger, K. M.; Kempe, M. D.; McMahon, T. J.

    2005-02-01

    A number of candidate alternative encapsulant and soft backsheet materials have been evaluated in terms of their suitability for photovoltaic (PV) module packaging applications. Relevant properties, including interfacial adhesion and moisture transport, have been measured as a function of damp-heat (85 C/85% relative humidity) exposure. Based on these tests, promising new encapsulants with improved properties have been identified. Backsheets prepared by industry and at NREL have been found to provide varying levels of moisture ingress protection. To achieve significantly improved products, further development of these candidates is ongoing. The relative effectiveness of various packaging strategies to protect PV devices has also been investigated.

  15. Building-integrated PV -- Analysis and US market potential

    SciTech Connect (OSTI)

    Frantzis, L.; Hill, S.; Teagan, P.; Friedman, D. [Arthur D. Little, Inc., Cambridge, MA (United States)

    1994-12-31

    Arthur D Little, Inc., in conjunction with Solar Design Associates, conducted a study for the US Department of Energy (DOE), Office of Building Technologies (OBT) to determine the market potential for building-integrated photovoltaics (BIPV). This study defines BIPV as two types of applications: (1) where the PV modules are an integral part of the building, often serving as the exterior weathering skin, and (2) the PV modules are mounted on the existing building exterior. Both of these systems are fully integrated with the energy usage of the building and have potential for significant market penetration in the US.

  16. Outdoor PV Module Degradation of Current-Voltage Parameters: Preprint

    SciTech Connect (OSTI)

    Smith, R. M.; Jordan, D. C.; Kurtz, S. R.

    2012-04-01

    Photovoltaic (PV) module degradation rate analysis quantifies the loss of PV power output over time and is useful for estimating the impact of degradation on the cost of energy. An understanding of the degradation of all current-voltage (I-V) parameters helps to determine the cause of the degradation and also gives useful information for the design of the system. This study reports on data collected from 12 distinct mono- and poly-crystalline modules deployed at the National Renewable Energy Laboratory (NREL) in Golden, Colorado. Most modules investigated showed < 0.5%/year decrease in maximum power due to short-circuit current decline.

  17. Toward integrated PV panels and power electronics using printing technologies

    SciTech Connect (OSTI)

    Ababei, Cristinel; Yuvarajan, Subbaraya; Schulz, Douglas L.

    2010-07-15

    In this paper, we review the latest developments in the area of printing technologies with an emphasis on the fabrication of control-embedded photovoltaics (PV) with on-board active and passive devices. We also review the use of power converters and maximum power point tracking (MPPT) circuits with PV panels. Our focus is on the investigation of the simplest implementations of such circuits in view of their integration with solar cells using printing technologies. We see this concept as potentially enabling toward further cost reduction. Besides a discussion as to feasibility, we shall also present some projections and guidelines toward possible integration. (author)

  18. Selecting Solar: Insights into Residential Photovoltaic (PV) Quote Variation

    SciTech Connect (OSTI)

    Davidson, Carolyn; Margolis, Robert

    2015-10-01

    Before investing in a system, a prospective PV customer must not only have initial concept 'buy in,' but also be able to evaluate the tradeoffs associated with different system parameters. Prospective customers might need to evaluate disparate costs for each system attribute by comparing multiple bids. The difficulty of making such an evaluation with limited information can create a cognitive barrier to proceeding with the investment. This analysis leverages recently available data from EnergySage, an online solar marketplace, to offer the first data-driven characterization of quote variation faced by prospective PV customers, lending early insight into the decisions customers face once they have initial buy-in.

  19. Modular Power Converters for PV Applications

    SciTech Connect (OSTI)

    Ozpineci, Burak; Tolbert, Leon M

    2012-05-01

    This report describes technical opportunities to serve as parts of a technological roadmap for Shoals Technologies Group in power electronics for PV applications. There are many different power converter circuits that can be used for solar inverter applications. The present applications do not take advantage of the potential for using common modules. We envision that the development of a power electronics module could enable higher reliability by being durable and flexible. Modules would have fault current limiting features and detection circuits such that they can limit the current through the module from external faults and can identify and isolate internal faults such that the remaining modules can continue to operate with only minimal disturbance to the utility or customer. Development of a reliable, efficient, low-cost, power electronics module will be a key enabling technology for harnessing more power from solar panels and enable plug and play operation. Power electronics for computer power supplies, communication equipment, and transportation have all targeted reliability and modularity as key requirements and have begun concerted efforts to replace monolithic components with collections of common smart modules. This is happening on several levels including (1) device level with intelligent control, (2) functional module level, and (3) system module. This same effort is needed in power electronics for solar applications. Development of modular units will result in standard power electronic converters that will have a lower installed and operating cost for the overall system. These units will lead to increased adaptability and flexibility of solar inverters. Incorporating autonomous fault current limiting and reconfiguration capabilities into the modules and having redundant modules will lead to a durable converter that can withstand the rigors of solar power generation for more than 30 years. Our vision for the technology roadmap is that there is no need for detailed design of new power converters for each new application or installation. One set of modules and controllers can be pre-developed and the only design question would be how many modules need to be in series or parallel for the specific power requirement. Then, a designer can put the modules together and add the intelligent reconfigurable controller. The controller determines how many modules are connected, but it might also ask for user input for the specific application during setup. The modules include protection against faults and can reset it, if necessary. In case of a power device failure, the controller reconfigures itself to continue limited operation until repair which might be as simple as taking the faulty module out and inserting a new module. The result is cost savings in design, maintenance, repair, and a grid that is more reliable and available. This concept would be a perfect fit for the recently announced funding opportunity announcement (DE-FOA-0000653) on Plug and Play Photovoltaics.

  20. Interline Photovoltaic (I-PV) power system - A novel concept of power flow control and management

    E-Print Network [OSTI]

    Khadkikar, Vinod

    This paper presents a new system configuration for a large-scale Photovoltaic (PV) power system with multi-line transmission/distribution networks. A PV power plant is reconfigured in a way that two adjacent power system ...

  1. Analyzing and simulating the variability of solar irradiance and solar PV powerplants

    E-Print Network [OSTI]

    Lave, Matthew S.

    2012-01-01

    the limits of solar photovoltaics (PV) in traditionalpenetrations of solar photovoltaics (PV) into an electricSolar Radiation Climatology in the Design of Photovoltaic Systems, Practical Handbook of Photovoltaics:

  2. Breakout Session: Getting in the Loop: PV Hardware Recycling and Sustainability

    Broader source: Energy.gov [DOE]

    As PV system installations continue to ramp up across the United States, the process for handling used and expired PV modules in the next  20-30 years would benefit from serious planning and...

  3. Dynamic Model Validation of PV Inverters Under Short-Circuit Conditions: Preprint

    SciTech Connect (OSTI)

    Muljadi, E.; Singh, M.; Bravo, R.; Gevorgian, V.

    2013-03-01

    Photovoltaic (PV) modules have dramatically decreased in price in the past few years, spurring the expansion of photovoltaic deployment. Residential and commercial rooftop installations are connected to the distribution network; large-scale installation PV power plants (PVPs) have benefited from tax incentives and the low cost of PV modules. As the level penetration of PV generation increases, the impact on power system reliability will also be greater. Utility power system planners must consider the role of PV generation in power systems more realistically by representing PV generation in dynamic stability analyses. Dynamic models of PV inverters have been developed in the positive sequence representation. NREL has developed a PV inverter dynamic model in PSCAD/EMTDC. This paper validates the dynamic model with an actual hardware bench test conducted by Southern California Edison's Distributed Energy Resources laboratory. All the fault combinations -- symmetrical and unsymmetrical -- were performed in the laboratory. We compare the simulation results with the bench test results.

  4. Shaking Up the Residential PV Market: Implications of Recent Changes to the ITC

    E-Print Network [OSTI]

    Bolinger, Mark

    2008-01-01

    credit. Case Studies of State Support for Renewable EnergyPV Market Case Studies of State Support for Renewable EnergyPV Market Case Studies of State Support for Renewable Energy

  5. Characterization of the Pseudomonas syringae pv. tomato AvrRpt2 protein: demonstration of secretion and

    E-Print Network [OSTI]

    Characterization of the Pseudomonas syringae pv. tomato AvrRpt2 protein: demonstration of secretion Pseudomonas syringae pv. tomato strain DC3000 (Pst DC3000) expressing avrRpt2 is speci®cally recognized

  6. Comparative Genomics of Multiple Strains of Pseudomonas cannabina pv. alisalensis, a Potential

    E-Print Network [OSTI]

    Dangl, Jeff

    Comparative Genomics of Multiple Strains of Pseudomonas cannabina pv. alisalensis, a Potential cannabina pv. alisalensis, a Potential Model Pathogen of Both Monocots and Dicots. PLoS ONE 8(3): e59366

  7. Approaches To Integrating A HIgh Penertration Of Solar PV and CPV Onto The Electrical Grid

    E-Print Network [OSTI]

    Hill, Steven Craig

    2013-01-01

    significant growth in the solar market beyond the 2,300 MWthe concentrated solar PV market. The proven flat panels leading market success in the installation of solar PV

  8. DOE Request for Information (RFI) DE-FOA-0000153 PV Manufacturing Initiative: Summary Report, February 2010

    SciTech Connect (OSTI)

    Not Available

    2010-02-01

    This document sums up results of the PV Manufacturing Request for Information (RFI), DE-FOA-0000153, which supports the PV Manufacturing Initiative, launched by DOE Solar Energy Technologies Program.

  9. Interline photovoltaic (I-PV) power plants for voltage unbalance compensation

    E-Print Network [OSTI]

    Moawwad, Ahmed

    This paper proposes a stationary-frame control method for voltage unbalance compensation using Interline Photovoltaic (I-PV) power system. I-PV power systems are controlled to compensate voltage unbalance autonomously. The ...

  10. Shaking Up the Residential PV Market: Implications of Recent Changes to the ITC

    E-Print Network [OSTI]

    Bolinger, Mark

    2008-01-01

    pay for a PV system’s solar renewable energy certificates (Efficiency and Renewable Energy, Solar Energy Technologiessolar Shaking Up the Residential PV Market Case Studies of State Support for Renewable

  11. Resonance in Optimal Perturbation Evolution. Part II: Effects of a Nonzero Mean PV Gradient

    E-Print Network [OSTI]

    de Vries, Hylke

    Resonance in Optimal Perturbation Evolution. Part II: Effects of a Nonzero Mean PV Gradient H. DE (PV) perturbations and the surface edge wave plays a key role in the surface dynamics (e.g. De Vries

  12. September 16 ESTAP Webinar: Optimizing the Benefits of a PV with...

    Office of Environmental Management (EM)

    6 ESTAP Webinar: Optimizing the Benefits of a PV with Battery Storage System September 16 ESTAP Webinar: Optimizing the Benefits of a PV with Battery Storage System August 30, 2013...

  13. Failure and Degradation Modes of PV Modules in a Hot Dry Climate...

    Office of Environmental Management (EM)

    Failure and Degradation Modes of PV Modules in a Hot Dry Climate: Results After 12 to 26 Years of Field Exposure Failure and Degradation Modes of PV Modules in a Hot Dry Climate:...

  14. Analyzing the Stability ofAnalyzing the Stability of --Carotene and PVCarotene and PV--1919

    E-Print Network [OSTI]

    Petta, Jason

    Analyzing the Stability ofAnalyzing the Stability of --Carotene and PVCarotene and PV--1919 nanoparticles #12;Goals of Second ProjectGoals of Second Project Study of PVStudy of PV--1919 --Determine

  15. Climatically Diverse Data Set for Flat-Plate PV Module Model Validations (Presentation)

    SciTech Connect (OSTI)

    Marion, B.

    2013-05-01

    Photovoltaic (PV) module I-V curves were measured at Florida, Colorado, and Oregon locations to provide data for the validation and development of models used for predicting the performance of PV modules.

  16. Berkeley Program Offers New Option for Financing Residential PV Systems

    SciTech Connect (OSTI)

    Bolinger, Mark A

    2008-07-06

    Readily accessible credit has often been cited as a necessary ingredient to open up the market for residential photovoltaic (PV) systems. Though financing does not reduce the high up-front cost of PV, by spreading that cost over some portion of the system's life, financing can certainly make PV systems more affordable. As a result, a number of states have, in the past, set up special residential loan programs targeting the installation of renewable energy systems and/or energy-efficiency improvements and often featuring low interest rates, longer terms and no-hassle application requirements. Historically, these loan programs have had mixed success (particularly for PV), for a variety of reasons, including a historical lack of homeowner interest in PV, a lack of program awareness, a reduced appeal in a low-interest-rate environment, and a tendency for early PV adopters to be wealthy and not in need of financing. Some of these barriers have begun to fade. Most notably, homeowner interest in PV has grown in some states, particularly those that offer solar rebates. The passage of the Energy Policy Act of 2005 (EPAct 2005), however, introduced one additional roadblock to the success of low-interest PV loan programs: a residential solar investment tax credit (ITC), subject to the Federal government's 'anti-double-dipping' rules. Specifically, the residential solar ITC--equal to 30% of the system's tax basis, capped at $2000--will be reduced or offset if the system also benefits from what is known as 'subsidized energy financing', which is likely to include most government-sponsored low-interest loan programs. Within this context, it has been interesting to note the recent flurry of announcements from a number of U.S cities concerning a new type of PV financing program. Led by the city of Berkeley, Calif., these cities propose to offer their residents the ability to finance the installation of a PV system using increased property tax assessments, rather than a more-traditional credit vehicle, to recover both system and administrative costs. This approach has a number of features that should appeal to PV owners, including long-term, fixed-cost, attractive financing; loans that are tied to the tax capacity of the property rather than to the owner's credit standing; a repayment obligation that transfers along with the sale of the property; and a potential ability to deduct the repayment obligation from federal taxable income as part of the local property tax deduction. For these reasons, Berkeley's program, which was first announced on October 23, 2007, has received considerable nationwide attention in both the trade and general press. Since the announcement, cities from throughout California and the broader U.S. have expressed keen interest in the possibility of replicating this type of program. In California alone, the cities of Santa Cruz, Santa Monica and Palm Desert are all reportedly considering similar programs, while the city of San Francisco has recently announced its own program, portions of which closely parallel Berkeley's approach. In addition, a bill (AB 811) that would authorize all cities in California, not just charter cities like Berkeley, to create this type of program was approved by the California General Assembly on January 29 and is currently under consideration in the State Senate. A similar bill in Colorado (HB 1350) was signed into law on May 28. Elsewhere, the city of Tucson, Arizona has also considered this financing approach.

  17. Junction Evolution During Fabrication of CdS/CdTe Thin-film PV Solar Cells (Presentation)

    SciTech Connect (OSTI)

    Gessert, T. A.

    2010-09-01

    Discussion of the formation of CdTe thin-film PV junctions and optimization of CdTe thin-film PV solar cells.

  18. The Economic Value of PV and Net Metering to Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim

    2010-01-01

    The Market Value and Cost of Solar Photovoltaic ElectricityTransmission Cost is a Substantial Benefit of Solar PV”, The

  19. Rethinking Standby & Fixed Cost Charges: Regulatory & Rate Design Pathways to Deeper Solar PV Cost Reductions

    Broader source: Energy.gov [DOE]

    While solar PV's impact on utilities has been frequently discussed the past year, little attention has been paid to the potentially impact posed by solar PV-specific rate designs (often informally referred to as solar "fees" or "taxes") upon non-hardware "soft" cost reductions. In fact, applying some rate designs to solar PV customers could potentially have a large impact on the economics of PV systems.

  20. Designing PV Incentive Programs to Promote System Performance: A Review of Current Practice

    E-Print Network [OSTI]

    Barbose, Galen; Wiser, Ryan; Bolinger, Mark

    2006-01-01

    Solar Rebate Program Solar & Small Wind Incentive ProgramSolar Electric and Wind Program (Small PV Program) **

  1. Regolamento_Meccanica_L3-PV-POLIMI.doc UNIVERSIT DEGLI STUDI DI PAVIA

    E-Print Network [OSTI]

    Segatti, Antonio

    Regolamento_Meccanica_L3-PV-POLIMI.doc UNIVERSITÃ? DEGLI STUDI DI PAVIA FACOLTÃ? di Ingegneria Classe

  2. Distributed Solar PV for Electricity System Resiliency: Policy and Regulatory Considerations (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2014-11-01

    Distributed Solar PV systems have the potential of increasing the grid's resiliency to unforeseen events, such as extreme weather events and attacks. This paper presents the role that distributed PV can play in electric grid resiliency, introduces basic system design requirements and options, and discusses the regulatory and policy options for supporting the use of distributed PV for the purpose of increased electricity resiliency.

  3. A methodology for optimal sizing of autonomous hybrid PV/wind system

    E-Print Network [OSTI]

    Boyer, Edmond

    A methodology for optimal sizing of autonomous hybrid PV/wind system S. Diaf 1* , D. Diaf2 , M paper presents a methodology to perform the optimal sizing of an autonomous hybrid PV/wind system system reliability requirements, with the lowest value of levelised cost of energy. Modelling a hybrid PV/wind

  4. 78 IAEI NEWS September.October 2006 www.iaei.org penetrating pv questions from inspectors

    E-Print Network [OSTI]

    Johnson, Eric E.

    78 IAEI NEWS September.October 2006 www.iaei.org penetrating pv questions from inspectors B ased several calls and e-mails a week and sometimes several calls a day from inspectors looking at PV plans or inspecting PV systems. The questions that they pose are always challenging because most of the inspectors

  5. agronomie: agriculture and environment Dtection d'Erwinia chrysanthemi pv dianthicola

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    agronomie: agriculture and environment Détection d'Erwinia chrysanthemi pv dianthicola par le test — L'indexage des boutures d'œillet vis-à-vis d'Erwinia chrysanthemi pv dianthicola (Ech son exploitation à grande échelle sont discutés sur le plan technique. Erwinia chrysanthemi pv

  6. QUANTIFYING RESIDENTIAL PV ECONOMICS IN THE US PAYBACK vs. CASH FLOW

    E-Print Network [OSTI]

    Perez, Richard R.

    QUANTIFYING RESIDENTIAL PV ECONOMICS IN THE US --- PAYBACK vs. CASH FLOW DETERMINATION OF FAIR by prospective PV owners. Contrasting this measure with another financial gauge -- life-cycle cash flow -- the paper discusses why payback may not be the most appropriate measure for residential PV applications

  7. RETI Phase 1B Final Report Update NET SHORT RECALCULATION AND NEW PV ASSUMPTIONS

    E-Print Network [OSTI]

    RETI Phase 1B Final Report Update NET SHORT RECALCULATION AND NEW PV ASSUMPTIONS With Revisions distributed photovoltaic (PV) installations in the Report is unclear and perhaps misleading. At the direction-generation is required. The CEC forecast assumed that 1,082 GWh will be self-generated by consumers from new PV

  8. 80 IAEI NEWS March.April 2008 www.iaei.org COMMON PV CODE VIOLATIONS

    E-Print Network [OSTI]

    Johnson, Eric E.

    80 IAEI NEWS March.April 2008 www.iaei.org COMMON PV CODE VIOLATIONS by John Wiles A s we move into 2008, the PV industry continues to grow by leaps and bounds. New module and inverter manufacturers are entering the industry, and the number of individuals and organizations install- ing PV systems is growing

  9. EVALUATION OF PV GENERATION CAPICITY CREDIT FORECAST ON DAY-AHEAD UTILITY MARKETS

    E-Print Network [OSTI]

    Perez, Richard R.

    EVALUATION OF PV GENERATION CAPICITY CREDIT FORECAST ON DAY-AHEAD UTILITY MARKETS Richard Perez predict the effective capacity of grid-connected PV power plants. The predicted and actual utility peak load reduction performance of PV power plants are compared for two case studies: ConEdison in New York

  10. PUBLISHED VERSION Workshop on performance variations in H ion sources 2012: PV H12

    E-Print Network [OSTI]

    PUBLISHED VERSION Workshop on performance variations in H ion sources 2012: PV H12 M. P. Stockli, D://dx.doi.org/10.1063/1.4792832 #12;Workshop on performance variations in H ion sources 2012: PV H12 M. P. Stockli Sources 2012: PV H- 120F * M. P. Stocklia , D. Fairclothb , W. Krausc , A. Andod , D. S. Bollingere , S

  11. SOLAR ENERGY (conditionally accepted 1/2010) QUANTIFYING PV POWER OUTPUT VARIABILITY

    E-Print Network [OSTI]

    Perez, Richard R.

    SOLAR ENERGY (conditionally accepted 1/2010) QUANTIFYING PV POWER OUTPUT VARIABILITY Thomas E power output variability from a fleet of photovoltaic (PV) systems, ranging from a single central station to a set of distributed PV systems. The approach demonstrates that the relative power output

  12. BATTERY-POWERED, ELECTRIC-DRIVE VEHICLES PROVIDING BUFFER STORAGE FOR PV CAPACITY VALUE

    E-Print Network [OSTI]

    Perez, Richard R.

    BATTERY-POWERED, ELECTRIC-DRIVE VEHICLES PROVIDING BUFFER STORAGE FOR PV CAPACITY VALUE Steven applications, batteries can serve to provide firm peak-shaving for distributed PV installations. To date, however, the use of batteries from parked electric- drive vehicles (EDV) to provide buffer storage for PV

  13. Evidence for Interhemispheric Processing of Inputs From the Hands in Human S2 and PV

    E-Print Network [OSTI]

    Krubitzer, Leah A.

    Evidence for Interhemispheric Processing of Inputs From the Hands in Human S2 and PV ELIZABETH S2 and PV. J Neurophysiol 85: 2236­2244, 2001. In the present investigation, we identified cortical somatosensory (S2) and the parietal ventral (PV) areas, was significantly larger for bilateral stimulation than

  14. TOWARDS A MEANINGFUL STANDARD FOR PV ARRAY INSTALLATION IN AUSTRALIA. T. Spooner O. Arteaga M. Calais

    E-Print Network [OSTI]

    TOWARDS A MEANINGFUL STANDARD FOR PV ARRAY INSTALLATION IN AUSTRALIA. T. Spooner O. Arteaga M@eng.murdoch.edu.au ABSTRACT: Photovoltaic (PV) arrays have been installed for many years in a very wide range of applications of a standard for PV array installation. This paper discusses important safety issues with respect to the design

  15. Environmental impacts of large-scale grid-connected ground-mounted PV installations

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Environmental impacts of large-scale grid-connected ground-mounted PV installations Antoine Beylota-scale ground-mounted PV installations by considering a life-cycle approach. The methodology is based. Mobile PV installations with dual-axis trackers show the largest impact potential on ecosystem quality

  16. VALIDATION OF PV PERFORMANCE MODELS USING SATELLITE-BASED IRRADIANCE MEASUREMENTS: A CASE STUDY

    E-Print Network [OSTI]

    Perez, Richard R.

    VALIDATION OF PV PERFORMANCE MODELS USING SATELLITE-BASED IRRADIANCE MEASUREMENTS: A CASE STUDY Clean Power Research Kirkland, WA e-mail: aparkins@cleanpower.com ABSTRACT Photovoltaic (PV) system and existing PV systems under a wide variety of environmental conditions. Ground based meteorological

  17. IEEE TRANSACTIONS ON POWER ELECTRONICS 1 A Hybrid Power Control Concept for PV Inverters with Reduced

    E-Print Network [OSTI]

    Kerekes, Tamas

    IEEE TRANSACTIONS ON POWER ELECTRONICS 1 Letters A Hybrid Power Control Concept for PV Inverters- cept for grid-connected Photovoltaic (PV) inverters. The control strategy is based on either a Maximum on the instantaneous available power from the PV panels. The essence of the proposed concept lies in the selection

  18. Aalborg Universitet Stability Analysis for Isolated AC Microgrids Based on PV-Active Generators

    E-Print Network [OSTI]

    Vasquez, Juan Carlos

    Aalborg Universitet Stability Analysis for Isolated AC Microgrids Based on PV-Active Generators for Isolated AC Microgrids Based on PV-Active Generators. In Proceedings of the 2015 IEEE Energy Conversion.aau.dk on: november 29, 2015 #12;Stability Analysis for Isolated AC Microgrids Based on PV-Active Generators

  19. Why Are Residential PV Prices in Germany So Much Lower Than in the United States?

    E-Print Network [OSTI]

    .S. installers, to collect data on residential PV soft costs ­ Comprehensively reviewed public and private consultant data relevant to the cost structure of residential PV in Germany · Focus is the preWhy Are Residential PV Prices in Germany So Much Lower Than in the United States? A Scoping

  20. DOE Request for Information (RFI) DE-FOA-0000153 PV Manufacturing Initiative

    SciTech Connect (OSTI)

    none,

    2010-02-01

    This draft report summarizes the results of the U.S. Department of Energy PV Manufacturing Request for Information (RFI), DE-FOA-0000153, that was released in September 2009. The PV Manufacturing Initiative is intended to help facilitate the development of a strong PV manufacturing industry in the United States.

  1. Aalborg Universitet On the Impact of Partial Shading on PV Output Power

    E-Print Network [OSTI]

    Sera, Dezso

    Aalborg Universitet On the Impact of Partial Shading on PV Output Power Sera, Dezso; Baghzouz version (APA): Sera, D., & Baghzouz, Y. (2008). On the Impact of Partial Shading on PV Output Power from vbn.aau.dk on: juli 06, 2015 #12;On the Impact of Partial Shading on PV Output Power DEZSO SERA

  2. Genomic Plasticity Enables Phenotypic Variation of Pseudomonas syringae pv. tomato DC3000

    E-Print Network [OSTI]

    Myers, Chris

    Genomic Plasticity Enables Phenotypic Variation of Pseudomonas syringae pv. tomato DC3000 Zhongmeng of a genomic anomaly in the region of 4.7 to 4.9 Mb of the Pseudomonas syringae pv. tomato (Pst) DC3000 genome in P. syringae. Citation: Bao Z, Stodghill PV, Myers CR, Lam H, Wei H-L, et al. (2014) Genomic

  3. Optimal Perturbations in the Eady Model: Resonance versus PV Unshielding H. DE VRIES

    E-Print Network [OSTI]

    de Vries, Hylke

    Optimal Perturbations in the Eady Model: Resonance versus PV Unshielding H. DE VRIES Institute August 2004) ABSTRACT Using a nonmodal decomposition technique based on the potential vorticity (PV, such that the initial surface potential temperature (PT) is zero. These nonmodal structures are used as PV building

  4. Impact of increased penetration of wind and PV solar resources on the

    E-Print Network [OSTI]

    Stoltz, Brian M.

    Impact of increased penetration of wind and PV solar resources on the bulk power system Vijay;Wind and PV solar grid interface · Modern wind turbine generators are typically rated between 1.5 MW through a power electronic converter 3 #12;Wind and PV solar grid interface 4 Schematic of Type 3 wind

  5. Response to Xanthomonas campestris pv. vesicatoria in Tomato Involves Regulation of Ethylene Receptor

    E-Print Network [OSTI]

    Klee, Harry J.

    Response to Xanthomonas campestris pv. vesicatoria in Tomato Involves Regulation of Ethylene ethylene's role in plant response to virulent and avirulent strains of Xanthomonas campestris pv overexpressing a wild-type NR cDNA were infected with virulent X. campestris pv. vesicatoria. Like the Nr mutant

  6. CONTINUOUS ROLL-TO-ROLL SERPENTINE DEPOSITION FOR HIGH THROUGHPUT a-Si PV MANUFACTURING

    E-Print Network [OSTI]

    Deng, Xunming

    CONTINUOUS ROLL-TO-ROLL SERPENTINE DEPOSITION FOR HIGH THROUGHPUT a-Si PV MANUFACTURING M. Izu, H. When this technique is incorporated into a continuous roll- to-roll PV manufacturing process a number of advantages in a fully automated high throughput PV module production plant [l-18

  7. Genome Sequence of Xanthomonas arboricola pv. Corylina, Isolated from Turkish Filbert in Colorado

    E-Print Network [OSTI]

    Boucher, Christina

    Genome Sequence of Xanthomonas arboricola pv. Corylina, Isolated from Turkish Filbert in Colorado pv. corylina. To our knowledge, this is the first published ge- nome of this pathovar of X, Zerillo MM, Snelling J, Boucher C, Tisserat N. 2013. Genome sequence of Xanthomonas arboricola pv

  8. INTELLIGENT PERFORMANCE CHECK OF PV SYSTEM OPERATION BASED ON SATELLITE DATA

    E-Print Network [OSTI]

    Heinemann, Detlev

    INTELLIGENT PERFORMANCE CHECK OF PV SYSTEM OPERATION BASED ON SATELLITE DATA A. Drews* , J. Betcke of a fully automated service for performance check and error detection for photovoltaic (PV) systems by daily surveillance. Malfunctions of a grid-connected PV system, e.g. drop out of single module strings

  9. Put-Call Parity (Castelli, 1877) C = P + S -PV(X). (19)

    E-Print Network [OSTI]

    Lyuu, Yuh-Dauh

    Put-Call Parity (Castelli, 1877) C = P + S - PV(X). (19) · Consider the portfolio of one short European call, one long European put, one share of stock, and a loan of PV(X). · All options are assumed - S + PV(X). c 2010 Prof. Yuh-Dauh Lyuu, National Taiwan University Page 185 #12;The Proof (continued

  10. FAILURE DETECTION ROUTINE FOR GRID CONNECTED PV SYSTEMS AS PART OF THE PVSAT-2 PROJECT

    E-Print Network [OSTI]

    Heinemann, Detlev

    FAILURE DETECTION ROUTINE FOR GRID CONNECTED PV SYSTEMS AS PART OF THE PVSAT-2 PROJECT S. Stettler1.stettler@enecolo.ch, tel. +41 44 994 9001, fax. +41 44 994 9005 ABSTRACT: Identification of energy losses in PV systems up automatically analysing the performance of PV systems and, in case of a malfunction, determining possible causes

  11. THE DEVELOPMENT AND COMMERCIALIZATION OF SOLAR PV TECHNOLOGY IN THE OIL Jonatan Pinksea,b

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    THE DEVELOPMENT AND COMMERCIALIZATION OF SOLAR PV TECHNOLOGY IN THE OIL INDUSTRY Jonatan Pinksea regarding solar PV technology investments, a renewable energy technology that has seen explosive growth towards the development and commercialization of solar PV technology. To investigate this, a multiple case

  12. Fraunhofer-Center fr Silizium-Photovoltaik CSP INTERPRETATION OF CELL FRACTURE IN PV

    E-Print Network [OSTI]

    © Fraunhofer-Center für Silizium-Photovoltaik CSP INTERPRETATION OF CELL FRACTURE IN PV MODULES stability of PV modules" #12;© Fraunhofer-Center für Silizium-Photovoltaik CSP Agenda Motivation of busbar (processing) Along busbar (operation wind, snow,...) Cracked cells in a PV Module after

  13. PV Interconnection Risk Analysis through Distribution System Impact Signatures and Feeder Zones

    E-Print Network [OSTI]

    PV Interconnection Risk Analysis through Distribution System Impact Signatures and Feeder Zones Grid Integration Sandia National Laboratories Albuquerque, NM, USA Abstract-- High penetrations of PV reliability problems. In order to improve the interconnection study process, the use of feeder zones and PV

  14. Remote performance check and automated failure identification for grid-connected PV systems

    E-Print Network [OSTI]

    Heinemann, Detlev

    Remote performance check and automated failure identification for grid-connected PV systems cloudy skies. This determines the quality of the PV simulation and finally the period of time, satellite data, PVSAT-2 1. Introduction Failure-free operation of grid-connected photovoltaic (PV) systems

  15. pV3 Batch User's Reference Manual for use with the following workstations

    E-Print Network [OSTI]

    Peraire, Jaime

    pV3 Batch User's Reference Manual Rev. 2.05 for use with the following workstations: Compaq ALPHAs. 2 #12;Contents 1 Introduction 4 2 pV3 Batch Server 5 2.1 Batch Server Startup.4 Advanced Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3 pV3 Post

  16. THERMOMECHANICS OF PV MODULES INCLUDING THE VISCOELASTICITY OF EVA Ulrich Eitner1,

    E-Print Network [OSTI]

    THERMOMECHANICS OF PV MODULES INCLUDING THE VISCOELASTICITY OF EVA Ulrich Eitner1, *, Matthias by a comparison to displacement experiments where the thermomechanical deformation of solar cells in a PV laminate in the cell distance is 170µm. Keywords: PV module, Encapsulation, Simulation, Reliability, Mechanics 1

  17. OUTDOOR PV PERFORMANCE EVALUATION OF THREE DIFFERENT MODELS: SINGLE-DIODE, SAPM AND LOSS FACTOR MODEL

    E-Print Network [OSTI]

    OUTDOOR PV PERFORMANCE EVALUATION OF THREE DIFFERENT MODELS: SINGLE-DIODE, SAPM AND LOSS FACTOR.steveransome.com ABSTRACT: This study examines the accuracy and value of three different PV module performance modeling. The equivalent circuit diode models (e.g., PVsyst, PV*SOL, CEC, etc.) are popular, but include technology

  18. The PV Formula Justified Theorem 1 For a certain cash flow C1, C2, . . . , Cn,

    E-Print Network [OSTI]

    Lyuu, Yuh-Dauh

    Prix pour essai de LA FONDATION P&V Au-delà du déclin 1 Prix pour essai de LA FONDATION P&V Au FONDATION P&V Au-delà du déclin 2 - démontrer comment la société peut réinvestir le champ de l

  19. The figure shows the current energy pay back time for PV

    E-Print Network [OSTI]

    The figure shows the current energy pay back time for PV systems using different cell technologies and installed either in Central Europe or Southern Europe. Argument B1 PV Fact Sheets Technology improvements: Manufacturing a PV system consumes more energy than it ever produces in its life time." The fact is

  20. Measuring PV System Series Resistance Without Full IV Curves Joshua S. Stein1

    E-Print Network [OSTI]

    Measuring PV System Series Resistance Without Full IV Curves Joshua S. Stein1 , Shawn McCaslin2 resistance of the PV module, string, or array that does not require measuring a full IV curve and current, which can be readily obtained using standard PV monitoring equipment; measured short circuit

  1. Design and Evaluation of a Modular Resonant Switched Capacitors Equalizer for PV Panels

    E-Print Network [OSTI]

    Design and Evaluation of a Modular Resonant Switched Capacitors Equalizer for PV Panels Shmuel (Sam of shaded panels in a serially connected PV array. The proposed solution is based on a modular approach module was designed for 185W PV panels and was found to boost the maximum available power by about 50

  2. PV Output Variability Modeling Using Satellite Imagery and Neural Matthew J. Reno1,2

    E-Print Network [OSTI]

    PV Output Variability Modeling Using Satellite Imagery and Neural Networks Matthew J. Reno1, Albuquerque, NM, USA Abstract -- Variability and ramp rates of PV systems are increasingly important to understand and model for grid stability as PV penetration levels rise. Using satellite imagery to identify

  3. A Uniform PV Framework for Balanced Dynamics vertical structure of the troposphere

    E-Print Network [OSTI]

    Muraki, David J.

    A Uniform PV Framework for Balanced Dynamics vertical structure of the troposphere surface & vertical displacement surface QG: balanced dynamics & uniform PV with vertical structure surface pressure & thickness vis-`a-vis 500 hPa vorticity & geopotential http://grads.iges.org 2 #12;PV Structure of the Lower

  4. Genome-Wide Identification of Transcriptional Start Sites in the Plant Pathogen Pseudomonas syringae pv. tomato

    E-Print Network [OSTI]

    Myers, Chris

    syringae pv. tomato str. DC3000 Melanie J. Filiatrault1,2 *, Paul V. Stodghill1,2 , Christopher R. Myers3 identified 59-ends of transcripts for the plant pathogen Pseudomonas syringae pv. tomato str. DC3000. Citation: Filiatrault MJ, Stodghill PV, Myers CR, Bronstein PA, Butcher BG, et al. (2011) Genome

  5. PV INVERTER PERFORMANCE AND RELIABILITY: WHAT IS THE ROLE OF THE IGBT?

    E-Print Network [OSTI]

    PV INVERTER PERFORMANCE AND RELIABILITY: WHAT IS THE ROLE OF THE IGBT? Robert Kaplar 1 , Reinhard the role of component failures in PV performance and reliability. Although there is no consensus these electronic components and to determine the underlying causes of inverter failures. The typical PV inverter

  6. Pseudomonas syringae pv. actinidiae (PSA) Isolates from Recent Bacterial Canker of Kiwifruit Outbreaks Belong to

    E-Print Network [OSTI]

    Guttman, David S.

    Pseudomonas syringae pv. actinidiae (PSA) Isolates from Recent Bacterial Canker of Kiwifruit fruit (Actinidia deliciosa and A. chinensis) caused by Pseudomonas syringae pv. actinidiae (PSA, Taratufolo MC, Cai R, Almeida NF, et al. (2012) Pseudomonas syringae pv. actinidiae (PSA) Isolates from

  7. PV Microinverter Testbed for Interoperability Jimmy E. Quiroz, Sigifredo Gonzalez, and Joshua S. Stein

    E-Print Network [OSTI]

    PV Microinverter Testbed for Interoperability Jimmy E. Quiroz, Sigifredo Gonzalez, and Joshua S in residential photovoltaic (PV) systems is increasing. This is due to the potential performance advantages that module mismatch and shading has on the power production of a PV system. While these attributes can have

  8. APPLICATION OF THE pV3 COPROCESSING VISUALIZATION ENVIRONMENT TO 3D UNSTRUCTURED MESH CALCULATIONS

    E-Print Network [OSTI]

    Peraire, Jaime

    APPLICATION OF THE pV3 CO­PROCESSING VISUALIZATION ENVIRONMENT TO 3­D UNSTRUCTURED MESH Moffett Field, CA 94035 barth@nas.nasa.gov (415) 604­6740 Introduction The pV3 visualization system­domain. The Visualization System pV3[2] is a complete distributed CFD­style visualization package. It is new, but builds

  9. Silicon Oxynitride Thin Film Barriers for PV Packaging (Poster)

    SciTech Connect (OSTI)

    del Cueto, J. A.; Glick, S. H.; Terwilliger, K. M.; Jorgensen, G. J.; Pankow, J. W.; Keyes, B. M.; Gedvilas, L. M.; Pern, F. J.

    2006-10-03

    Dielectric, adhesion-promoting, moisture barriers comprised of silicon oxynitride thin film materials (SiOxNy with various material stoichiometric compositions x,y) were applied to: 1) bare and pre-coated soda-lime silicate glass (coated with transparent conductive oxide SnO2:F and/or aluminum), and polymer substrates (polyethylene terephthalate, PET, or polyethylene napthalate, PEN); plus 2) pre- deposited photovoltaic (PV) cells and mini-modules consisting of amorphous silicon (a-Si) and copper indium gallium diselenide (CIGS) thin-film PV technologies. We used plasma enhanced chemical vapor deposition (PECVD) process with dilute silane, nitrogen, and nitrous oxide/oxygen gas mixtures in a low-power (< or = 10 milliW per cm2) RF discharge at ~ 0.2 Torr pressure, and low substrate temperatures < or = 100(degrees)C, over deposition areas ~ 1000 cm2. Barrier properties of the resulting PV cells and coated-glass packaging structures were studied with subsequent stressing in damp-heat exposure at 85(degrees)C/85% RH. Preliminary results on PV cells and coated glass indicate the palpable benefits of the barriers in mitigating moisture intrusion and degradation of the underlying structures using SiOxNy coatings with thicknesses in the range of 100-200 nm.

  10. Impact of PV forecasts uncertainty in batteries management in microgrids

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Impact of PV forecasts uncertainty in batteries management in microgrids Andrea Michiorri Arthur-based battery schedule optimisation in microgrids in presence of network constraints. We examine a specific case production forecast algorithm is used in combination with a battery schedule optimisation algorithm. The size

  11. Smart Grid Inverters for High-Penetration PV Applications

    E-Print Network [OSTI]

    Smart Grid Inverters for High- Penetration PV Applications Hawai`i Natural Energy Institute of recognized energy industry leaders working to develop enhanced capability smart inverters and to demonstrate by deploying and evaluating smart inverters on operating utility distribution feeders in two locations

  12. Performance and Analysis of Photovoltaic (PV)Technologies

    E-Print Network [OSTI]

    Performance and Analysis of Photovoltaic (PV)Technologies at Selected Sites This report presents As part of Cooperative Agreement No. DE-EE0003507 Under Task 3.1: Photovoltaic Systems September 2014`i at Manoa #12;Performance and Analysis of Different Photovoltaic Technologies at Selected Sites Prepared

  13. SunShot Presentation PV Module Reliabity Workshop Opening Session

    Office of Energy Efficiency and Renewable Energy (EERE)

    This PowerPoint slide deck was originally presented at the opening session of the 2013 NREL PV Module Reliability Workshop on Feb. 26-27, 2013 in Golden, CO. It provides an overview of the DOE SunShot initiative, discusses systems integration and technology validation activities, and highlighted the goals and key agenda items for the workshop.

  14. Minnesota Power- Solar-Electric (PV) Rebate Program

    Office of Energy Efficiency and Renewable Energy (EERE)

    Minnesota Power offers a rebate of $1,000 per kilowatt (kW) DC for grid-connected solar-electric (PV) systems, with a maximum award of $20,000 per customer or 60% installed costs per customer. This...

  15. IRRADIANCE MAPS APPLIED FOR THE PERFORMANCE ASSESSMENT OF PV SYSTEMS

    E-Print Network [OSTI]

    Heinemann, Detlev

    FEDERAL STATE OF SAXONY 1 Institute of Electrical Engineering,University of Applied Sciences (FH energy yield of a PV system,methods based on irradiance maps published by weather services or others of the irradiance data has been done by checking a set of monthly energy yield data of well-running grid

  16. November 21, 2000 PV Lesson Plan 1 Solar Cells

    E-Print Network [OSTI]

    Oregon, University of

    November 21, 2000 PV Lesson Plan 1 ­ Solar Cells Prepared for the Oregon Million Solar Roofs High School Gary Grace ­ South Eugene High School In Schools #12;1 Solar Cells Lesson Plan Content: In this lesson, students are introduced to the basic physics and chemistry behind the operation of a solar cell

  17. Integrating PV into Performance Contracts: Barriers and Trends

    E-Print Network [OSTI]

    Delaware, University of

    Project (REPP) discuss the theory of bundling PV with energy efficiency in performance contracts "ESCOs are businesses that develop, install, and finances projects designed to improve energy efficiency it is consumed, solar energy has been championed as a response to looming concerns of resource depletion, air

  18. PV SOLAR RESOURCE GUIDE FOR RURAL DISTRIBUTORS IN TN Introduction

    E-Print Network [OSTI]

    McCarthy, John F.

    April 2013 Asa Roy PV SOLAR RESOURCE GUIDE FOR RURAL DISTRIBUTORS IN TN #12;1 Introduction experience with solar power. Research and interviews with the Tennessee's Green Power Providers Program, Green Power Providers Coordinators at several urban distributors, and solar installers in Tennessee

  19. Utility Scale Solar PV Cost Steven SimmonsSteven Simmons

    E-Print Network [OSTI]

    to 2020 (DOE) Energy Department Announces $12 million to Accelerate Record Breaking Solar Cell Efficiency Nuclear Generating Station. 4 #12;6/19/2013 3 EVEN MORE SUNNY HEADLINES New solar panels glisten6/19/2013 1 Utility Scale Solar PV Cost Steven SimmonsSteven Simmons Northwest Power

  20. Selecting Solar. Insights into Residential Photovoltaic (PV) Quote Variation

    SciTech Connect (OSTI)

    Davidson, Carolyn; Margolis, Robert

    2015-10-01

    This analysis leverages available data from EnergySage, an online solar marketplace, to offer the first data-driven characterization of quote variation faced by prospective PV customers, lending early insight into the decisions customers face once they have initial buy-in.

  1. November 21, 2000 PV Lesson Plan 2 Solar Electric Arrays

    E-Print Network [OSTI]

    Oregon, University of

    . (Solar irradiance is electromagnetic energy from the sun. Electromagnetic energy from other sources such as lamps can also be used by solar cells to generate electricity if the energy of the photons is highNovember 21, 2000 PV Lesson Plan 2 ­ Solar Electric Arrays Prepared for the Oregon Million Solar

  2. EPJ Photovoltaics 2, 20301 (2011) www.epj-pv.org

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    2011-01-01

    EPJ Photovoltaics 2, 20301 (2011) www.epj-pv.org DOI: 10.1051/epjpv/2011001 c Owned by the authors, published by EDP Sciences, 2011 EPJ PhotovoltaicsEPJ Photovoltaics Geometrical optimization and electrical online: 1 April 2011 Abstract This article investigates the optimal efficiency of a photovoltaic system

  3. ELUCIDATING THE DIFFERENCES BETWEEN ONSITE AND OFFSITE SHIPMENT OF RADIOACTIVE MATERIALS

    SciTech Connect (OSTI)

    Loftin, B.; Watkins, R.

    2013-06-19

    Federal regulations stipulate how radioactive materials are transported within the United States. However, the Department of Energy, under Department of Energy Order, has the authority to operate, within the boundaries of their physical site, to other stipulations. In many cases the DOE sites have internal reviews for onsite transfers that rival reviews performed by the regulatory authorities for offsite shipments. Most of the differences are in the level or type of packaging that is required, but in some cases it may be in the amount and type of material that is allowed to be transferred. This paper will describe and discuss those differences and it will discuss ways to effectively align the onsite rules for transferring materials with those for offsite shipment.

  4. A rationale for maintaining the double containment requirement for plutonium shipments

    SciTech Connect (OSTI)

    Channell, James K.; Anastas, George

    2003-12-31

    Current U.S. Nuclear Regulatory Commission (NRC) transportation regulations (10 CFR 71.63 (b)) require that all shipments containing more than 20 curies of plutonium must be transported in packages that provide double containment. On April 30, 2002 the NRC issued a proposed rule that would eliminate §71.63(b) and the double containment requirement. NRC’s reasons for proposing elimination of §71.63(b) are: (1) compatibility with International Atomic Energy Agency Transportation Safety Standards (which do not have the requirement); (2) the current rule is inconsistent with the A1/A2 system since it applies only to plutonium; (3) double containment causes a heavier package and results in higher transportation costs; (4) the separate inner containment results in additional radiation exposure; and (5) while there would be additional protection from a separate inner container in an accident; this type of approach is not “risk informed nor performance based.” The Environmental Evaluation Group (EEG) has been a proponent of the double containment requirement for the Waste Isolation Pilot Plant (WIPP) shipments for twenty years. This requirement affects shipments to WIPP much more than any other current or planned shipping campaign because reactor fuel elements, metal or metal alloy, and vitrified high-level waste are exempt from §71.63(b). EEG submitted comments on the Proposed Rule on July 26, 2002 (Appendix C). This report is an update and expansion of the July 26, 2002 comments. Actual WIPP experience with shipments in the double contained TRUPACT-II package is used to respond to NRC arguments for deletion of §71.63(b) and offers a rationale for maintaining the current requirement.

  5. Solar PV Manufacturing Cost Model Group: Installed Solar PV System Prices (Presentation)

    SciTech Connect (OSTI)

    Goodrich, A. C.; Woodhouse, M.; James, T.

    2011-02-01

    EERE's Solar Energy Technologies Program is charged with leading the Secretary's SunShot Initiative to reduce the cost of electricity from solar by 75% to be cost competitive with conventional energy sources without subsidy by the end of the decade. As part of this Initiative, the program has funded the National Renewable Energy Laboratory (NREL) to develop module manufacturing and solar PV system installation cost models to ensure that the program's cost reduction targets are carefully aligned with current and near term industry costs. The NREL cost analysis team has leveraged the laboratories' extensive experience in the areas of project finance and deployment, as well as industry partnerships, to develop cost models that mirror the project cost analysis tools used by project managers at leading U.S. installers. The cost models are constructed through a "bottoms-up" assessment of each major cost element, beginning with the system's bill of materials, labor requirements (type and hours) by component, site-specific charges, and soft costs. In addition to the relevant engineering, procurement, and construction costs, the models also consider all relevant costs to an installer, including labor burdens and overhead rates, supply chain costs, and overhead and materials inventory costs, and assume market-specific profits.

  6. Experimental comparison of PV-smoothing controllers using distributed generators

    SciTech Connect (OSTI)

    Johnson, Jay Dean; Ellis, Abraham; Denda, Atsushi; Morino, Kimio; Hawkins, John N.; Arellano, Brian; Shinji, Takao; Ogata, Takao; Tadokoro, Masayuki

    2014-02-01

    The power output variability of photovoltaic systems can affect local electrical grids in locations with high renewable energy penetrations or weak distribution or transmission systems. In those rare cases, quick controllable generators (e.g., energy storage systems) or loads can counteract the destabilizing effects by compensating for the power fluctuations. Previously, control algorithms for coordinated and uncoordinated operation of a small natural gas engine-generator (genset) and a battery for smoothing PV plant output were optimized using MATLAB/Simulink simulations. The simulations demonstrated that a traditional generation resource such as a natural gas genset in combination with a battery would smooth the photovoltaic output while using a smaller battery state of charge (SOC) range and extending the life of the battery. This paper reports on the experimental implementation of the coordinated and uncoordinated controllers to verify the simulations and determine the differences in the controllers. The experiments were performed with the PNM PV and energy storage Prosperity site and a gas engine-generator located at the Aperture Center at Mesa Del Sol in Albuquerque, New Mexico. Two field demonstrations were performed to compare the different PV smoothing control algorithms: (1) implementing the coordinated and uncoordinated controls while switching off a subsection of the PV array at precise times on successive clear days, and (2) comparing the results of the battery and genset outputs for the coordinated control on a high variability day with simulations of the coordinated and uncoordinated controls. It was found that for certain PV power profiles the SOC range of the battery may be larger with the coordinated control, but the total amp-hours through the battery-which approximates battery wear-will always be smaller with the coordinated control.

  7. Integrating High Penetrations of PV into Southern California: Year 2 Project Update; Preprint

    SciTech Connect (OSTI)

    Mather, B.; Neal, R.

    2012-08-01

    Southern California Edison (SCE) is well into a five-year project to install a total of 500 MW of distributed photovoltaic (PV) energy within its utility service territory. Typical installations to date are 1-3 MW peak rooftop PV systems that interconnect to medium-voltage urban distribution circuits or larger (5 MW peak) ground-mounted systems that connect to medium-voltage rural distribution circuits. Some of the PV system interconnections have resulted in distribution circuits that have a significant amount of PV generation compared to customer load, resulting in high-penetration PV integration scenarios. The National Renewable Energy Laboratory (NREL) and SCE have assembled a team of distribution modeling, resource assessment, and PV inverter technology experts in order to investigate a few of the high-penetration PV distribution circuits. Currently, the distribution circuits being studied include an urban circuit with a PV penetration of approximately 46% and a rural circuit with a PV penetration of approximately 60%. In both cases, power flow on the circuit reverses direction, compared to traditional circuit operation, during periods of high PV power production and low circuit loading. Research efforts during year two of the five-year project were focused on modeling the distribution system level impacts of high-penetration PV integrations, the development and installation of distribution circuit data acquisition equipment appropriate for quantifying the impacts of high-penetration PV integrations, and investigating high-penetration PV impact mitigation strategies. This paper outlines these research efforts and discusses the following activities in more detail: the development of a quasi-static time-series test feeder for evaluating high-penetration PV integration modeling tools; the advanced inverter functions being investigated for deployment in the project's field demonstration and a power hardware-in-loop test of a 500-kW PV inverter implementing a limited set of advanced inverter functions.

  8. Sensitivity of Rooftop PV Projections in the SunShot Vision Study to Market Assumptions

    SciTech Connect (OSTI)

    Drury, E.; Denholm, P.; Margolis, R.

    2013-01-01

    The SunShot Vision Study explored the potential growth of solar markets if solar prices decreased by about 75% from 2010 to 2020. The SolarDS model was used to simulate rooftop PV demand for this study, based on several PV market assumptions--future electricity rates, customer access to financing, and others--in addition to the SunShot PV price projections. This paper finds that modeled PV demand is highly sensitive to several non-price market assumptions, particularly PV financing parameters.

  9. Solar Photovoltaic Economic Development: Building and Growing a Local PV Industry, August 2011 (Book)

    SciTech Connect (OSTI)

    Not Available

    2011-08-01

    The U.S. photovoltaic (PV) industry is forecast to grow, and it represents an opportunity for economic development and job creation in communities throughout the United States. This report helps U.S. cities evaluate economic opportunities in the PV industry. It serves as a guide for local economic development offices in evaluating their community?s competitiveness in the solar PV industry, assessing the viability of solar PV development goals, and developing strategies for recruiting and retaining PV companies to their areas.

  10. Literature Review of Uncertainty of Analysis Methods (PV F-Chart Program), Report to the Texas Commission on Environmental Quality 

    E-Print Network [OSTI]

    Haberl, J. S.; Cho, S.

    2004-01-01

    This report reviews the reported uncertainty of the PV F-Chart analysis method by reviewing the published related accuracy of PV F-Chart analysis versus measured data, PV F-Chart predictions versus other methods, and PV F-Chart predictions versus...

  11. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim

    2010-01-01

    which TOU Rate is Least Cost PV-to-Load Ratio PGE (N=118)which TOU Rate is Least Cost PV-to-Load Ratio South facingfor which TOU rate is Least Cost PV-to-Load Ratio PV-to-Load

  12. ON THE PURE VIRTUAL BRAID GROUP PV3 V. G.BARDAKOV, R. MIKHAILOV, V. V. VERSHININ, AND J. WU

    E-Print Network [OSTI]

    Wu, Jie

    ON THE PURE VIRTUAL BRAID GROUP PV3 V. G.BARDAKOV, R. MIKHAILOV, V. V. VERSHININ, AND J. WU Abstract. We investigate various properties of the pure virtual braid group PV3. Out of its presentation, we get a free product decomposition of PV3. As a consequence, we show that PV3 is residually torsion

  13. Within the free troposphere, PV is conserved by frictionless, adiabatic motion. However, friction and diabatic processes in the

    E-Print Network [OSTI]

    Plant, Robert

    Within the free troposphere, PV is conserved by frictionless, adiabatic motion. However, friction and diabatic processes in the boundary layer can create or destroy PV. PV is generated in the warm PV anomaly above the low centre, confined in the vertical but spread in the horizontal. This shape

  14. Quantify Degradation Rates and Mechanisms of PV Modules and Systems Installed in Florida Through Comprehensive Experimental and Theoretical Analysis (Poster)

    SciTech Connect (OSTI)

    Sorloaica-Hickman, N.; Davis, K.; Kurtz, S.; Jordan, D.

    2011-02-01

    The economic viability of photovoltaic (PV) technologies is inextricably tied to both the electrical performance and degradation rate of the PV systems, which are the generators of electrical power in PV systems. Over the past 15 years, performance data have been collected on numerous PV systems installed throughout the state of Florida and will be presented.

  15. A PV Dynamics for Rotating Shallow Water on the Sphere search for a balance dynamics on the full sphere

    E-Print Network [OSTI]

    Muraki, David J.

    A PV Dynamics for Rotating Shallow Water on the Sphere search for a balance dynamics on the full vorticity (PV) geometric obstacle: local Rossby number singular at Equator, 1 #12;rSW on the Full Sphere r2 gH0 !-1/2 1 Balanced Dynamics PV Inversion on a Hemisphere, McIntyre/Norton 1999 landmark for PV

  16. Calmodulin-like proteins from Arabidopsis and tomato are involved in host defense against Pseudomonas syringae pv. tomato

    E-Print Network [OSTI]

    Huang, Ching-Tsan

    Pseudomonas syringae pv. tomato David Chiasson, Sophia K. Ekengren, Gregory B. Martin, Stephanie L Dobney

  17. J. Adv. Model. Earth Syst., Vol. 2, Art. #8, 19 pp. Adiabatic Rearrangement of Hollow PV Towers

    E-Print Network [OSTI]

    Schubert, Wayne H.

    J. Adv. Model. Earth Syst., Vol. 2, Art. #8, 19 pp. Adiabatic Rearrangement of Hollow PV Towers potential vorticity (PV). is structure has been referred to as a hollow PV tower. e sign reversal of the radial gradient of PV satis es the Charney-Stern necessary condition for combined barotropic

  18. PG&E Plans for 500 MW of PV

    Office of Energy Efficiency and Renewable Energy (EERE)

    PG&E has developed a plan to install 500 MW of PV by the year 2015. The plan calls for 250 MW to be acquired through Power Purchase Agreements (PPA) and the other 250 MW to be purchased and owned by the utility. PG&E presented the plan at a public forum on April 27, 2009. A copy of the power point presentation is attached.

  19. Designing Auction-Based PV Incentives | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum Based| Department8, 20153Danielthrough theKDesertDesigning Auction-Based PV

  20. Measurement uncertainty analysis techniques applied to PV performance measurements

    SciTech Connect (OSTI)

    Wells, C.

    1992-10-01

    The purpose of this presentation is to provide a brief introduction to measurement uncertainty analysis, outline how it is done, and illustrate uncertainty analysis with examples drawn from the PV field, with particular emphasis toward its use in PV performance measurements. The uncertainty information we know and state concerning a PV performance measurement or a module test result determines, to a significant extent, the value and quality of that result. What is measurement uncertainty analysis It is an outgrowth of what has commonly been called error analysis. But uncertainty analysis, a more recent development, gives greater insight into measurement processes and tests, experiments, or calibration results. Uncertainty analysis gives us an estimate of the I interval about a measured value or an experiment's final result within which we believe the true value of that quantity will lie. Why should we take the time to perform an uncertainty analysis A rigorous measurement uncertainty analysis: Increases the credibility and value of research results; allows comparisons of results from different labs; helps improve experiment design and identifies where changes are needed to achieve stated objectives (through use of the pre-test analysis); plays a significant role in validating measurements and experimental results, and in demonstrating (through the post-test analysis) that valid data have been acquired; reduces the risk of making erroneous decisions; demonstrates quality assurance and quality control measures have been accomplished; define Valid Data as data having known and documented paths of: Origin, including theory; measurements; traceability to measurement standards; computations; uncertainty analysis of results.

  1. www.iaei.org May.June 2006 IAEI NEWS 85 THE 15-MINUTE PV SYSTEM INSPECTION

    E-Print Network [OSTI]

    Johnson, Eric E.

    www.iaei.org May.June 2006 IAEI NEWS 85 THE 15-MINUTE PV SYSTEM INSPECTION by John Wiles The 15-minuteThe 15-minute PV System InspectionPV System Inspection CaCan You? Should You?n You? Should You? The 15-minuteThe 15-minute PV System InspectionPV System Inspection CaCan You? Should You?n You? Should

  2. Exploring the Economic Value of EPAct 2005's PV Tax Credits

    SciTech Connect (OSTI)

    Bolinger, Mark A; Wiser, Ryan; Ing, Edwin

    2009-08-01

    This CESA - LBNL Case Study examines how much economic value do new and expanded federal tax credits really provide to PV system purchasers, and what implications might they hold for state/utility PV grant programs. The report begins with a discussion of the taxability of PV grants and their interaction with federal credits, as this issue significantly affects the analysis that follows. We then calculate the incremental value of EPAct's new and expanded credits for PV systems of different sizes, and owned by different types of entities. The report concludes with a discussion of potential implications for purchasers of PV systems, as well as for administrators of state/utility PV programs. The market for grid-connected photovoltaics (PV) in the US has grown dramatically in recent years, driven in large part by PV grant or 'buy-down' programs in California, New Jersey, and many other states. The recent announcement of a new 11-year, $3.2 billion PV program in California suggests that state policy will continue to drive even faster growth over the next decade. Federal policy has also played a role, primarily by providing commercial PV systems access to tax benefits, including accelerated depreciation (5-year MACRS schedule) and a business energy investment tax credit (ITC). Since the signing of the Energy Policy Act of 2005 (EPAct) on August 8, the federal government has begun to play a much more significant role in supporting both commercial and residential PV systems. Specifically, EPAct increased the federal ITC for commercial PV systems from 10% to 30% of system costs, and also created a new 30% ITC (capped at $2000) for residential solar systems. Both changes went into effect on January 1, 2006, for an initial period of two years, and in late 2006 were extended for an additional year. Unless extended further, the new residential ITC will expire, and the 30% commercial ITC will revert back to 10%, on January 1, 2009. How much economic value do these new and expanded federal tax credits really provide to PV system purchasers? And what implications might they hold for state/utility PV grant programs? Using a generic (i.e., non-state-specific) cash flow model, this report explores these questions.1 We begin with a discussion of the taxability of PV grants and their interaction with federal credits, as this issue significantly affects the analysis that follows. We then calculate the incremental value of EPAct's new and expanded credits for PV systems of different sizes, and owned by different types of entities. We conclude with a discussion of potential implications for purchasers of PV systems, as well as for administrators of state/utility PV programs.

  3. AN EVALUATION OF PYROLYSIS OIL PROPERTIES AND CHEMISTRY AS RELATED TO PROCESS AND UPGRADE CONDITIONS WITH SPECIAL CONSIDERATION TO PIPELINE SHIPMENT

    SciTech Connect (OSTI)

    Bunting, Bruce G; Boyd, Alison C

    2012-01-01

    One factor limiting the development of commercial biomass pyrolysis is challenges related to the transportation of the produced pyrolysis oil. The oil has different chemical and physical properties than crude oil, including more water and oxygen and has lower H/C ratio, higher specific gravity and density, higher acidity, and lower energy content. These differences could limit its ability to be transported by existing petroleum pipelines. Pyrolysis oil can also be treated, normally by catalytic hydrodeoxygenation, and approaches crude oil and petroleum condensates at higher severity levels. This improvement also results in lower liquid yield and high hydrogen consumption. Biomass resources for pyrolysis are expected to become plentiful and widely distributed in the future, mainly through the use of crop residuals and growing of energy crops such as perennial grasses, annual grasses, and woody crops. Crude oil pipelines are less well distributed and, when evaluated on a county level, could access about 18% of the total biomass supply. States with high potential include Texas, Oklahoma, California, and Louisiana. In this study, published data on pyrolysis oil was compiled into a data set along with bio-source source material, pyrolysis reactor conditions, and upgrading conditions for comparison to typical crude oils. Data of this type is expected to be useful in understanding the properties and chemistry and shipment of pyrolysis oil to refineries, where it can be further processed to fuel or used as a source of process heat.

  4. Evaluation of PV performance models and their impact on project risk.

    SciTech Connect (OSTI)

    Stein, Joshua S.; Hansen, Clifford W.; Cameron, Christopher P.

    2010-12-01

    Photovoltaic systems are often priced in $/W{sub p}, where Wp refers to the DC power rating of the modules at Standard Test Conditions (1000 W/m{sup 2}, 25 C cell temperature) and $ refers to the installed cost of the system. However, the true value of the system is in the energy it will produce in kWhs, not the power rating. System energy production is a function of the system design and location, the mounting configuration, the power conversion system, and the module technology, as well as the solar resource. Even if all other variables are held constant, the annual energy yield (kWh/kW{sup p}) will vary among module technologies because of differences in response to low-light levels and temperature. Understanding energy yield is a key part of understanding system value. System performance models are used during project development to estimate the expected output of PV systems for a given design and location. Performance modeling is normally done by the system designer/system integrator. Often, an independent engineer will also model system output during a due diligence review of a project. A variety of system performance models are available. The most commonly used modeling tool for project development and due diligence in the United States is probably PVsyst, while those seeking a quick answer to expected energy production may use PVWatts. In this paper, we examine the variation in predicted energy output among modeling tools and users and compare that to measured output.

  5. Annual Reports

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 OutreachProductswsicloudwsiclouddenDVA N C E D B L O O D S TAPropaneandAn319 125 U.S.812AnnualFinalAnnual

  6. Annual Report

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on DeliciousMathematics And StatisticsProgram ManagerCorridor Designations inEnergy 4 Report AnnualAnnual Planning09

  7. Annual Report

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p a l De p u t yWaste |4 2014 Annual Planning Summary for the2011 Annual

  8. Packaging and Transportation for Offsite Shipment of Materials of National Security Interest

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2016-01-05

    The Order establishes requirements and responsibilities for ensuring the safety of packaging and transportation for offsite shipments of Materials of National Security Interest. DOE Order 461.1C received a significant number of major and suggested comments the first time it was reviewed in RevCom. As a result of the number of comments received, the OPI have a second RevCom review. This revision of DOE O 461.1C incorporates changes which resulted from the comment resolution process of the initial draft.

  9. Packaging and Transportation for Offsite Shipment of Materials of National Security Interests

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2015-09-25

    The Order establishes requirements and responsibilities for ensuring the safety of packaging and transportation for offsite shipments of Materials of National Security Interest. DOE Order 461.1C received a significant number of major and suggested comments the first time it was reviewed in RevCom. As a result of the number of comments received, the OPI have a second RevCom review. This revision of DOE O 461.1C incorporates changes which resulted from the comment resolution process of the initial draft.

  10. Advanced development of PV encapsulants. Annual subcontract report, 30 December 1992--31 March 1994

    SciTech Connect (OSTI)

    Holley, W.; Agro, S.; Galica, J.; Thoma, L.; White, R.; Yorgensen, R. [Springborn Labs., Inc., Enfield, CT (United States)

    1994-11-01

    This report describes work under Phase II of a Photovoltaic Manufacturing Technology project to conduct laboratory problem definition with an emphasis on controlled aging studies to evaluate the influence of various compositional, processing, and operating parameters on ethylene vinyl acetate (EVA) discoloration. In support of future accelerated UV aging studies (AAS) of coupon-sized EVA laminates, an Atlas xenon arc Ci35A Weather-Ometer was procured, installed, and calibrated for temperature and irradiance. In preparing for the AAS studies, UV-visible spectroscopy measurements were performed on various types of low-iron glass, representive of materials used for module superstrates. It was discovered that the transmission spectra of some of the grades in the UV region from 250 to 400 nm was significantly different. Older grades of Solatex and solite, and StarPhire 'cut off' well below 290 nm, while newer grades of Solatex and Solite, and StarPhire and Airphire greatly reduce the UV transmittance between 280 and 330 nm. Controlled aging studies are presently underway at 0.55 W/m2, 340 nm, and 100 degrees C, and we expect comparative data on yellowing to be available soon.

  11. Photovoltaics (PV) as an Eligible Measure in Residential PACE Programs: Benefits and Challenges (Fact Sheet)

    SciTech Connect (OSTI)

    Coughlin, J.

    2010-06-01

    Property Assessed Clean Energy (PACE) financing is one of several new financial models broadening access to clean energy by addressing the barrier of initial capital cost. The majority of the PACE programs in the market today include PV as an eligible measure. PV appeals to homeowners as a way to reduce utility bills, self-generate sustainable power, increase energy independence and demonstrate a commitment to the environment. If substantial state incentives for PV exist, PV projects can be economic under PACE, especially when partnered with good net metering policies. At the same time, PV is expensive relative to other eligible measures with a return on investment horizon that might exceed program targets. This fact sheet reviews the benefits and potential challenges of including PV in PACE programs.

  12. NREL Annual Environmental Performance Reports (Annual Site Environment...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    NREL Annual Environmental Performance Reports (Annual Site Environmental Reports) NREL Annual Environmental Performance Reports (Annual Site Environmental Reports) Every year NREL...

  13. SAPC Best Practices in PV System Installation: Version 1.0, March...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Authority Sydney Roberts, SouthFace Benjamin Shih, Moody's Chris Sommerfeld, Sunrun Jeff Spies, Quick Mount PV Josh Sturtevant, Distributed Sun Teresa W. Zhang, PhD,...

  14. PV Supply Chain and Cross-Cutting Technologies: Upcoming Funding Opportunity

    SciTech Connect (OSTI)

    Not Available

    2008-10-01

    Summarizes the Solar Program's upcoming funding opportunity, called PV Supply Chain and Cross-Cutting Technologies, which is expected to be open by the end of October 2008.

  15. Sustainable and Holistic Integration of Energy Storage and Solar PV (SHINES) Funding Opportunity

    Office of Energy Efficiency and Renewable Energy (EERE)

    The Sustainable and Holistic Integration of Energy Storage and Solar PV (SHINES) solution as envisioned by SunShot will have the following features:

  16. THE IMPACT OF CITY-LEVEL PERMITTING PROCESSES ON RESIDENTIAL PV INSTALLATION PRICES AND DEVELOPMENT TIMES

    E-Print Network [OSTI]

    Dong, Changgui

    2014-01-01

    Renewable Energy Council (13) Sunrun. 2011. The Impact ofSan Francisco, CA: Sunrun (14) Tong, J. 2012. NationwideTong, 2012); earlier, Sunrun (2011) reported PV installation

  17. Technology Choices for the PV Industry: A Comparative Life Cycle Assessment

    E-Print Network [OSTI]

    Boyd, Sarah; Dornfeld, David A

    2005-01-01

    2000), “Environmental Life Cycle Assessment of Solar HomePV INDUSTRY: A Comparative Life Cycle Assessment Sarah Boydinput-output life cycle assessment (EIOLCA) to capture both

  18. Property Tax Assessments as a Finance Vehicle for Residential PV Installations: Opportunities and Potential Limitations

    E-Print Network [OSTI]

    Bolinger, Mark

    2008-01-01

    for Renewable Energy ability to finance the installation offor Renewable Energy loans to finance their PV system (orany subsidized energy financing used to finance the system.

  19. Pyranometers and Reference Cells: Part 2: What Makes the Most Sense for PV Power Plants?; Preprint

    SciTech Connect (OSTI)

    Meydbray, J.; Riley, E.; Dunn, L.; Emery, K.; Kurtz, S.

    2012-10-01

    As described in Part 1 of this two-part series, thermopile pyranometers and photovoltaic (PV) reference cells can both be used to measure irradiance; however, there are subtle differences between the data that are obtained. This two-part article explores some implications of uncertainty and subtleties of accurately measuring PV efficiency in the field. Part 2 of the series shows how reference cells can be used to more confidently predict PV performance, but how this could best be accomplished if historic irradiance data could be available in PV-technology-specific formats.

  20. Precursor Report of Data Needs and Recommended Practices for PV Plant Availability Operations and Maintenance Reporting.

    SciTech Connect (OSTI)

    Hill, Roger R.; Klise, Geoffrey Taylor; Balfour, John R.

    2015-01-01

    Characterizing the factors that affect reliability of a photovoltaic (PV) power plant is an important aspect of optimal asset management. This document describes the many factors that affect operation and maintenance (O&M) of a PV plant, identifies the data necessary to quantify those factors, and describes how data might be used by O&M service providers and others in the PV industry. This document lays out data needs from perspectives of reliability, availability, and key performance indicators and is intended to be a precursor for standardizing terminology and data reporting, which will improve data sharing, analysis, and ultimately PV plant performance.

  1. Designing PV Incentive Programs to Promote System Performance: A Review of Current Practice

    E-Print Network [OSTI]

    Barbose, Galen; Wiser, Ryan; Bolinger, Mark

    2006-01-01

    communication with New York State Energy Research andSolar Pioneer Program New York Energy $mart PV IncentivePower Authority (LIPA) New York State Energy Research and

  2. Partially Shaded Operation of a Grid-Tied PV System: Preprint

    SciTech Connect (OSTI)

    Deline, C.

    2009-06-01

    This paper presents background and experimental results from a single-string grid-tied PV system, operated under a variety of shading conditions.

  3. An Analysis of Residential PV System Price Differences Between the United States and Germany

    E-Print Network [OSTI]

    Seel, Joachim

    2014-01-01

    A levelized cost of electricity (LCoE) analysis based on thePV system prices could reduce LCoE assumptions: 25-year life

  4. Holdover inoculum of Pseudomonas syringae pv. alisalensis from broccoli raab causes disease in subsequent plantings

    E-Print Network [OSTI]

    Cintas, N A; Koike, S T; Bunch, R A; Bull, C T

    2006-01-01

    alisalensis from Broccoli Raab Causes Disease in Subsequentalisalensis from broccoli raab causes disease in subsequentsyringae pv. maculicola causes bacterial spot on many

  5. Approaches To Integrating A HIgh Penertration Of Solar PV and CPV Onto The Electrical Grid

    E-Print Network [OSTI]

    Hill, Steven Craig

    2013-01-01

    FERC) and the National Electrical Regulatory Corporation (Of Solar PV and CPV Onto The Electrical Grid By Steven Craig24  Electrical, Controls & 

  6. Community Renewable Energy Success Stories Webinar: Developing PV Projects with RFPs and PPAs (text version)

    Broader source: Energy.gov [DOE]

    Below is the text version of the webinar titled "Developing PV Projects with RFPS and PPAS," originally presented on January 15, 2013.

  7. Do PV Systems Increase Residential Selling Prices If So, How Can Practitioners Estimate This Increase?

    E-Print Network [OSTI]

    Hoen, Ben

    2013-01-01

    National Laboratory’s Photovoltaic System Valuation Model –of the Effects of Photovoltaic Energy Systems on Residentialimpacts of photovoltaic (PV) energy systems on home sales

  8. Analyzing and simulating the variability of solar irradiance and solar PV powerplants

    E-Print Network [OSTI]

    Lave, Matthew S.

    2012-01-01

    Distributed PV, American Solar Energy Society, Denver, CO,of distance, Submitted to Solar Energy, (2011). [8] T. Hoff,Variability, Submitted to Solar Energy, (2011). [9] J.

  9. Defining a Technical Basis for Confidence in PV Investments - A Pathway to Service Life Prediction (Presentation)

    SciTech Connect (OSTI)

    Kurtz, S.; Wohlgemuth, J.; Kempe, M.; Bosco, N.; Hacke, P.; Jordan, D.; Miller, D.

    2013-09-01

    Four levels of accelerated test standards for PV modules are described in the context of how the community can most quickly begin using these.

  10. Approaches To Integrating A HIgh Penertration Of Solar PV and CPV Onto The Electrical Grid

    E-Print Network [OSTI]

    Hill, Steven Craig

    2013-01-01

    million acres of ideal solar potential, mostly west of thethe potential issues facing rooftop solar installations.investigate the potential conflicts of floating solar PV on

  11. Present experience of NRI REZ with preparation of spent nuclear fuel shipment to Russian Federation

    SciTech Connect (OSTI)

    Svitak, F.; Broz, V.; Hrehor, M.; Marek, M.; Novosad, P.; Podlaha, J.; Rychecky, J. [Nuclear Research Institute Rez plc, Husinec 130, CZ-25068 (Czech Republic)

    2008-07-15

    The Nuclear Research Institute Rez plc (NRI) jointed the Russian Research Reactor Fuel Return (RRRFR) programme under the US-Russian Global Threat Reduction Initiative (GTRI) initiative and started the preparation of the spent nuclear fuel (SNF) shipment from the LVR-15 research reactor back to the Russian Federation (RF). The transport of 16 SKODA VPVR/M casks with EK-10, IRT-2M 80 %, and IRT-2M 36% fuel types is planned for the autumn of 2007. The paper describes the experience gained so far during the preparatory works for the SNF shipment (facility equipment modification, cask licenses) and the actual preparation of the SNF for transport, in particular its checking, repacking in a hot cell, loading into the VPVR/M casks, drying, manipulation, completion of the transport documentation, etc., including its transport to the SNF storage facility at the NRI before it is shipped to the RF. The paper also briefly describes a regulatory framework for these activities with a focus on legislative and methodological aspects of the return of vitrified waste back to the Czech Republic. (author)

  12. Measurement uncertainty analysis techniques applied to PV performance measurements

    SciTech Connect (OSTI)

    Wells, C.

    1992-10-01

    The purpose of this presentation is to provide a brief introduction to measurement uncertainty analysis, outline how it is done, and illustrate uncertainty analysis with examples drawn from the PV field, with particular emphasis toward its use in PV performance measurements. The uncertainty information we know and state concerning a PV performance measurement or a module test result determines, to a significant extent, the value and quality of that result. What is measurement uncertainty analysis? It is an outgrowth of what has commonly been called error analysis. But uncertainty analysis, a more recent development, gives greater insight into measurement processes and tests, experiments, or calibration results. Uncertainty analysis gives us an estimate of the I interval about a measured value or an experiment`s final result within which we believe the true value of that quantity will lie. Why should we take the time to perform an uncertainty analysis? A rigorous measurement uncertainty analysis: Increases the credibility and value of research results; allows comparisons of results from different labs; helps improve experiment design and identifies where changes are needed to achieve stated objectives (through use of the pre-test analysis); plays a significant role in validating measurements and experimental results, and in demonstrating (through the post-test analysis) that valid data have been acquired; reduces the risk of making erroneous decisions; demonstrates quality assurance and quality control measures have been accomplished; define Valid Data as data having known and documented paths of: Origin, including theory; measurements; traceability to measurement standards; computations; uncertainty analysis of results.

  13. Zhejiang Cineng PV Science Technology Co Ltd | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page| Open Energy Information Serbia-EnhancingEtGeorgia:Illinois:WizardYates County,Zena, New York: EnergyLakeCineng PV

  14. PV vs. Solar Water Heating- Simple Solar Payback

    Broader source: Energy.gov [DOE]

    Solar energy systems hang their hats on payback. Financial payback is as tangible as money in your bank account, while other types of payback—like environmental externalities—are not usually calculated in dollars. There’s no doubt that photovoltaic (PV) and solar hot water (SHW) systems will pay you back. Maybe not as quickly as you’d like, but all systems will significantly offset their cost over their lifetimes. Here we’ll try to answer: Which system will give the quickest return on investment (ROI)?

  15. Decays of Charmed Mesons to PV Final States

    E-Print Network [OSTI]

    Bhubanjyoti Bhattacharya; Jonathan L. Rosner

    2008-12-16

    New data on the decays of the charmed particles $D^0$, $D^+$, and $D_s$ to $PV$ final states consisting of a light pseudoscalar meson $P$ and a light vector meson $V$ are analyzed. Following the same methods as in a previous analysis of $D \\to PP$ decays, one can test flavor symmetry, extract key key amplitudes, and obtain information on relative strong phases. Analyses are performed for Cabibbo-favored decays and then extended to predict properties of singly- and doubly-Cabibbo-suppressed processes.

  16. Kauai, Hawaii: Solar Resource Analysis and High Penetration PV Potential

    SciTech Connect (OSTI)

    Helm, C.; Burman, K.

    2010-04-01

    Overview of the solar resource assessment conducted by the National Renewable Energy Laboratory (NREL) in cooperation with Kauai Island Utility Cooperative (KIUC) in Hawaii to determine the technical feasibility of increasing the contribution of solar renewable energy generation on the island of Kauaii through the use of photovoltaic (PV) arrays. The analysis, which was performed using a custom version of NREL's In My Back Yard (IMBY) software tool, showed that there is potential to generate enough energy to cover the peak load as reported for Kauai in 2007.

  17. New Barrier Coating Materials for PV Module Backsheets: Preprint

    SciTech Connect (OSTI)

    Barber, G. D.; Jorgensen, G. J.; Terwilliger, K.; Glick, S. H.; Pern, J.; McMahon, T. J.

    2002-05-01

    This conference paper describes the high moisture barrier high resistivity coatings on polyethylene terepthalate (PET) have been fabricated and characterized for use in PV module back sheet applications. These thin film barriers exhibit water vapor transmission rates (WVTR) as low as 0.1 g/m2-day at 37.8 C and have shown excellent adhesion (> 10 N/mm) to both ethylene vinyl acetate (EVA) and PET even after filtered xenon arc lamp UV exposure. The WVTR and adhesion values for this construction are compared to and shown to be superior to candidate polymeric backsheet materials.

  18. Shanghai JTU PV Technology Co Ltd | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page| Open Energy Information Serbia-Enhancing Capacity for Low EmissionTianhong Silicon MaterialNewHuiyang NewJTU PV

  19. Inner Mongolia Dunan PV power | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QAsource History View NewTexas: Energy ResourcesOrder at 8, 13 (Vt.Infinifuel BiodieselfDunan PV power Jump to:

  20. Masdar PV GmbH | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX ECoop Inc Jump to: navigation, searchScotland Jump to:MarshallMaryville UtilitiesPV GmbH

  1. PvT Capital Gmbh | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX ECoop Inc Jump to:Newberg,Energy LLCALLETE Inc dEAPrysmianPvT Capital Gmbh Jump to:

  2. PV Validation and Bankability Workshop | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankADVANCED MANUFACTURINGEnergy Bills andOrder 422.1, CONDUCT P - .Energy 5PV Validation and Bankability

  3. PV Validation and Bankability Workshop | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankADVANCED MANUFACTURINGEnergy Bills andOrder 422.1, CONDUCT P - .Energy 5PV Validation and

  4. Jinzhou Prime Solar PV Technology Co Ltd | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LISTStar2-0057-EAInvervar Hydro JumpHuari Silicon Material Co Ltd Jump to:CenturyPV

  5. Siemens PV Technology now Konarka | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX ECoop Inc JumpHeter Battery Technology CoWanping HydropowerYongxiangPV Technology now

  6. BIOHAUS PV Handels GmbH | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmental Jump to:EAandAmminex AAustria Geothermal RegionAvraPáginasSolarBBBFCLandsBIOHAUS PV

  7. Yangrui PV Technology Fujian Co Ltd | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX ECoop IncIowa (UtilityMichigan) Jump to: Name:XinjiangPuping Electric PowerYangrui PV

  8. Sandia Energy - PV Performance Modeling Collaborative's New and

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II)Geothermal Energy &WaterNew CREWOnline Abstracts andPV Modeling

  9. Sandia Energy - Sandia PV Team Publishes Book Chapter

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II)Geothermal EnergyRenewable EnergyWAvesLawrenceImpactsPV Team Publishes

  10. 2010 ANNUAL RESEARCH REPORT 2010 ANNUAL RESEARCH REPORT 2010 ANNUAL RESEARCH REPORT RESEARCH REPORT2010ANNUAL RESEARCH REPORT2010ANNUAL RESEARCH REPORT

    E-Print Network [OSTI]

    Hill, Jeffrey E.

    2010 ANNUAL RESEARCH REPORT 2010 ANNUAL RESEARCH REPORT 2010 ANNUAL RESEARCH REPORT RESEARCH REPORT2010ANNUAL RESEARCH REPORT2010ANNUAL RESEARCH REPORT 2010 ANNUAL RESEARCH REPORT 2010 ANNUAL RESEARCH REPORT 2010 ANNUAL RESEARCH REPORT RESEARCH REPORT2010ANNUAL RESEARCH REPORT2010ANNUAL RESEARCH REPORT

  11. Electricity Rate Structures and the Economics of Solar PV: Could Mandatory Time-of-Use Rates Undermine California’s Solar Photovoltaic Subsidies?

    E-Print Network [OSTI]

    Borenstein, Severin

    2007-01-01

    distribution of possible solar PV costs, so for about halfbelow the range of solar PV costs. . e g a r e v a n o , r eare data on the cost of installing solar PV systems because

  12. Electricity Rate Structures and the Economics of Solar PV: Could Mandatory Time-of-Use Rates Undermine California’s Solar Photovoltaic Subsidies?

    E-Print Network [OSTI]

    Borenstein, Severin

    2007-01-01

    of possible solar PV costs, so for about half of this samplebelow the range of solar PV costs. . e g a r e v a n o , r es cost of ?nancing. This cost of PV power should then be

  13. Electricity Rate Structures and the Economics of Solar PV: Could Mandatory Time-of-Use Rates Undermine California’s Solar Photovoltaic Subsidies?

    E-Print Network [OSTI]

    Borenstein, Severin

    2007-01-01

    Wohlgemuth, “E?ects of soiling on PV module and radiometerand the Economics of Solar PV: Could Mandatory Time-of-Useand the Economics of Solar PV: Could Mandatory Time-of-Use

  14. OsWRKY62 is a negative regulator of basal and Xa21-mediated defense against Xanthomonas oryzae pv. oryzae in rice.

    E-Print Network [OSTI]

    2008-01-01

    to Xanthomonas ory- zae pv. oryzae in rice, encodes an LRRto Xanthomonas oryzae pv. oryzae. Plant J. 43, Chern, M. ,of Xantho- monas oryzae pv. oryzae AvrXa21 and implications

  15. Purification of soluble and active RaxH, a transmembrane histidine protein kinase from Xanthomonas oryzae pv. oryzae required for AvrXa21 activity.

    E-Print Network [OSTI]

    Stolov, Avital; Valverde, Angel; Ronald, Pamela; Burdman, Saul

    2007-01-01

    to multiple Xanthomonas oryzae pv. oryzae isolates insystem in Xanthomonas oryzae pv. oryzae required for AvrXa21genes from Xanthomonas oryzae pv. oryzae. Mol. Plant–Microbe

  16. Future of Grid-Tied PV Business Models: What Will Happen When PV Penetration on the Distribution Grid is Significant? Preprint

    SciTech Connect (OSTI)

    Graham, S.; Katofsky, R.; Frantzis, L.; Sawyer, H.; Margolis, R.

    2008-05-01

    Eventually, distributed PV will become a more significant part of the generation mix. When this happens, it is expected that utilities will have to take on a more active role in the placement, operation and control of these systems. There are operational complexities and concerns of revenue erosion that will drive utilities into greater involvement of distributed PV and will create new business models. This report summarizes work done by Navigant Consulting Inc. for the National Renewable Energy Laboratory as part of the Department of Energy's work on Renewable System Integration. The objective of the work was to better understand the structure of these future business models and the research, development and demonstration (RD&D) required to support their deployment. This report describes potential future PV business models in terms of combinations of utility ownership and control of the PV assets, and the various relationships between end-users and third-party owners.

  17. Solar San Diego: The Impact of Binomial Rate Structures on Real PV Systems; Preprint

    SciTech Connect (OSTI)

    VanGeet, O.; Brown, E.; Blair, T.; McAllister, A.

    2008-05-01

    There is confusion in the marketplace regarding the impact of solar photovoltaics (PV) on the user's actual electricity bill under California Net Energy Metering, particularly with binomial tariffs (those that include both demand and energy charges) and time-of-use (TOU) rate structures. The City of San Diego has extensive real-time electrical metering on most of its buildings and PV systems, with interval data for overall consumption and PV electrical production available for multiple years. This paper uses 2007 PV-system data from two city facilities to illustrate the impacts of binomial rate designs. The analysis will determine the energy and demand savings that the PV systems are achieving relative to the absence of systems. A financial analysis of PV-system performance under various rate structures is presented. The data revealed that actual demand and energy use benefits of binomial tariffs increase in summer months, when solar resources allow for maximized electricity production. In a binomial tariff system, varying on- and semi-peak times can result in approximately $1,100 change in demand charges per month over not having a PV system in place, an approximate 30% cost savings. The PV systems are also shown to have a 30%-50% reduction in facility energy charges in 2007.

  18. Literature Review of the Effects of UV Exposure on PV Modules

    Broader source: Energy.gov [DOE]

    This PowerPoint presentation, originally presented at the NREL 2013 PV Module Reliability Workshop on Feb. 26-27, 2013 in Denver, CO, presents the literature review of the effects of prolonged UV exposure of PV modules, with a particular emphasis on UV exposure testing using artificial light sources, including fluorescent, Xenon, and metal halide lamps.

  19. Optimal Design of Hybrid Energy System with PV/ Wind Turbine/ Storage: A Case Study

    E-Print Network [OSTI]

    Wierman, Adam

    Optimal Design of Hybrid Energy System with PV/ Wind Turbine/ Storage: A Case Study Rui Huang with photovoltaic (PV) arrays, wind turbines, and battery storage is designed based on empirical weather and load with renewable resources such as solar and wind power, supplemented with battery storage in a case study. One

  20. Energy and Society (ER100/PP184/ER200/PP284) Topics: PV, Wind, environmental justice

    E-Print Network [OSTI]

    Kammen, Daniel M.

    above to the average residential electricity rates in each of these cities. In which cities is electricity from PV equal to or cheaper than retail rates? [2 points] GRADUATE STUDENTS ONLY: Concerning Rate (¢/kWh) 16.5 19.2 10.30 12.3 PV electricity is more expensive than residential rates in Detroit