Powered by Deep Web Technologies
Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Noise analysis of single-qumode Gaussian operations using continuous-variable cluster states  

E-Print Network (OSTI)

We consider measurement-based quantum computation that uses scalable continuous-variable cluster states with a one-dimensional topology. The physical resource, known here as the dual-rail quantum wire, can be generated using temporally multiplexed offline squeezing and linear optics or by using a single optical parametric oscillator. We focus on an important class of quantum gates, specifically Gaussian unitaries that act on single modes, which gives universal quantum computation when supplemented with multi-mode operations and photon-counting measurements. The dual-rail wire supports two routes for applying single-qumode Gaussian unitaries: the first is to use traditional one-dimensional quantum-wire cluster-state measurement protocols. The second takes advantage of the dual-rail quantum wire in order to apply unitaries by measuring pairs of qumodes called macronodes. We analyze and compare these methods in terms of the suitability for implementing single-qumode Gaussian measurement-based quantum computation.

Rafael N. Alexander; Seiji C. Armstrong; Ryuji Ukai; Nicolas C. Menicucci

2014-10-13T23:59:59.000Z

2

Supplement analysis for continued operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore. Volume 2: Comment response document  

SciTech Connect

The US Department of Energy (DOE), prepared a draft Supplement Analysis (SA) for Continued Operation of Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratories, Livermore (SNL-L), in accordance with DOE`s requirements for implementation of the National Environmental Policy Act of 1969 (NEPA) (10 Code of Federal Regulations [CFR] Part 1021.314). It considers whether the Final Environmental Impact Statement and Environmental Impact Report for Continued Operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore (1992 EIS/EIR) should be supplement3ed, whether a new environmental impact statement (EIS) should be prepared, or no further NEPA documentation is required. The SA examines the current project and program plans and proposals for LLNL and SNL-L, operations to identify new or modified projects or operations or new information for the period from 1998 to 2002 that was not considered in the 1992 EIS/EIR. When such changes, modifications, and information are identified, they are examined to determine whether they could be considered substantial or significant in reference to the 1992 proposed action and the 1993 Record of Decision (ROD). DOE released the draft SA to the public to obtain stakeholder comments and to consider those comments in the preparation of the final SA. DOE distributed copies of the draft SA to those who were known to have an interest in LLNL or SNL-L activities in addition to those who requested a copy. In response to comments received, DOE prepared this Comment Response Document.

NONE

1999-03-01T23:59:59.000Z

3

AUTHORIZATION TO CONTINUE OPERATION OF  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Contract Competition] Contract Competition] AUTHORIZATION TO CONTINUE OPERATION OF THE_[insert the name of the laboratory/site/facility]___ UNDER A MANAGEMENT AND OPERATING CONTRACT The _[insert the name of the laboratory/site/facility]_ is currently managed and operated by _[insert the name of the contractor]_ for the Department of Energy under a Management and Operating (M&O) contract as defined in Federal Acquisition Regulation (FAR) Subpart 17.6. The current contract and the determination authorizing the M&O form of contract expire on _[insert the expiration date]_. _[In one or two sentences, briefly describe the laboratory/site/facility mission]_. A new contract is currently being procured by the DOE _[insert DOE office name]_, under Request for Proposals (RFP) number _[insert RFP number]_. The resultant

4

AUTHORIZATION TO CONTINUE OPERATION OF  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Non-competitive Extension] Non-competitive Extension] AUTHORIZATION TO CONTINUE OPERATION OF THE_[insert the name of the laboratory/site/facility]___ UNDER A MANAGEMENT AND OPERATING CONTRACT The _[insert the name of the laboratory/site/facility]_ is currently managed and operated by _[insert the name of the contractor]_ for the Department of Energy under DOE contract _[insert contract number]._This contract is a Management and Operating (M&O) contract as defined in Federal Acquisition Regulation (FAR) Subpart 17.6. The current contract and the determination authorizing the M&O form of contract expire on _[insert the expiration date]_. A non-competitive extension is currently being pursued in accordance with FAR 6.301. [In one or two sentences, briefly describe the

5

Continuity of Operations Plan (COOP)  

NLE Websites -- All DOE Office Websites (Extended Search)

You are here: DOE-ID Home > COOP Continuity of Operations Plan (COOP) Call-In Number: 1-208-526-COOP (2667) or 1-877-DOE-DOE1 (1-877-363-3631) Wait for recording to start then Dial 382: If you are directed or forced to evacuate your current location to an alternate site, please contact us as soon as possible to advise us that you are safe and with a means of contacting you. This toll free or local number can be used by employees or their families to report their whereabouts or the whereabouts of another DOE-ID employee. Email Check-In: In addition to the call-in number, employees and families can report their status via a email check-in system. To access the email please click here. The email based check in system should only be used by DOE ID Employees.

6

The Case for Continuing RHIC Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

2 2 Drafted by Steve Vigdor Revised with extensive feedback from RHIC user and support community 9/2/2012 The Case for Continuing RHIC Operations 1 The Case for Continuing RHIC Operations Table of Contents 1. The Case in a Nutshell ........................................................................................................................... 2 2. Hot QCD Matter: RHIC's Intellectual Challenges and Greatest Hits To Date ....................................... 4 3. Recent Breakthroughs and RHIC's Versatility Inform the Path Forward .............................................. 5 4. Unanticipated Intellectual Connections ............................................................................................. 16 5. Cold QCD Matter Studies at RHIC ....................................................................................................... 18

7

Supplement Analysis for the Final Environmental Impact Statement for the Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapon Components  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

D D E P A R T M E N T O F E N E R G Y U N I T E D S T A T E S O F A M E R I C A SUPPLEMENT ANALYSIS FOR THE FINAL ENVIRONMENTAL IMPACT STATEMENT FOR THE CONTINUED OPERATION OF THE PANTEX PLANT AND ASSOCIATED STORAGE OF NUCLEAR WEAPON COMPONENTS DOE/EIS-0225/SA-03 United States Department of Energy National Nuclear Security Administration Pantex Site Operations P.O. Box 30030 Amarillo, Texas 79120-0030 February 2003 i Summary The U.S. Department of Energy's (DOE's) National Environmental Policy Act (NEPA) Implementing Procedures at 10 CFR 1021.330(d) require evaluation of its site-wide environmental impact statements (EISs) at least every 5 years by preparation of a supplement analysis (SA), as provided in 10 CFR 1021.314. Based on the SA, a determination is made as to whether the existing EIS remains

8

Continuous Air Monitor Operating Experience Review  

SciTech Connect

Continuous air monitors (CAMs) are used to sense radioactive particulates in room air of nuclear facilities. CAMs alert personnel of potential inhalation exposures to radionuclides and can also actuate room ventilation isolation for public and environmental protection. This paper presents the results of a CAM operating experience review of the DOE Occurrence Reporting and Processing System (ORPS) database from the past 18 years. Regulations regarding these monitors are briefly reviewed. CAM location selection and operation are briefly discussed. Operating experiences reported by the U.S. Department of Energy and in other literature sources were reviewed to determine the strengths and weaknesses of these monitors. Power losses, human errors, and mechanical issues cause the majority of failures. The average “all modes” failure rate is 2.65E-05/hr. Repair time estimates vary from an average repair time of 9 hours (with spare parts on hand) to 252 hours (without spare parts on hand). These data should support the use of CAMs in any nuclear facility, including the National Ignition Facility and the international ITER experiment.

L. C. Cadwallader; S. A. Bruyere

2008-09-01T23:59:59.000Z

9

Continuity of Operations at Bonneville Power Administration, IG-0781 |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Continuity of Operations at Bonneville Power Administration, Continuity of Operations at Bonneville Power Administration, IG-0781 Continuity of Operations at Bonneville Power Administration, IG-0781 In the event of a major disruption to its nonnal operations, Bonneville must be prepared to continue its essential functions, particularly its power scheduling, tra~lsmission scheduling, and system operations. In this regard, Bonneville is required to follow Federal Preparedness Circular 65 (FPC 65), as prescribed by the Department of Homeland Security's Federal Emergency Management Agency. Under FPC 65, agencies are to develop viable contingency plans. The Circular also provides a number of key steps that agencies should take for continuity of operations. Specifically, it recommends that each agency: ( I ) prepare alternate operating facilities; (2)

10

DOE/EIS-0157-SA-01; Supplement Analysis for Continued Operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Oakland Operations Office, Oakland, California Oakland Operations Office, Oakland, California 6833/(0(17 $1$/<6,6 147 &RQWLQXHG 2SHUDWLRQ RI /DZUHQFH /LYHUPRUH 1DWLRQDO /DERUDWRU\ DQG 6DQGLD 1DWLRQDO /DERUDWRULHV /LYHUPRUH 9ROXPH , 0DLQ 5HSRUW March 1999 DOE/EIS-0157-SA-01 6833/(0(17 $1$/<6,6 147 &RQWLQXHG 2SHUDWLRQ RI /DZUHQFH /LYHUPRUH 1DWLRQDO /DERUDWRU\ DQG 6DQGLD 1DWLRQDO /DERUDWRULHV /LYHUPRUH 9ROXPH , 0DLQ 5HSRUW March 1999 DOE/EIS-0157-SA-01 Supplement Analysis March 1999 iii CONTENTS NOTATION......................................................................................................................... vii SUMMARY......................................................................................................................... S-1 1 INTRODUCTION..........................................................................................................

11

Continuous Operation of Foamed Emulsion Bioreactors Treating Toluene Vapors  

E-Print Network (OSTI)

.interscience.wiley.com). DOI: 10.1002/bit.20619 Abstract: Continuous operation of a new bioreactor for air pollution control Periodicals, Inc. Keywords: VOC control; biofilter; air pollution control; toluene; biologically activated biofilters and biotrickling filters for the treatment of air pollutants such as toluene. Ã? 2005 Wiley

12

Relativistic Heavy Ion Collider | The Case for Continuing Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

The Case for Continuing RHIC Operations The Case for Continuing RHIC Operations The Relativistic Heavy Ion Collider (RHIC) - the nation's only remaining particle collider, located at Brookhaven National Laboratory - has made a series of landmark discoveries and continuing breakthroughs in science and technology. One major accomplishment has been RHIC's ability to recreate and study in detail a type of matter that last existed at the beginning of the universe to better understand the strongest force in nature - the force that holds together the fundamental particles that make up 99 percent of visible matter in the universe today, everything from stars to planets to people. In addition to giving us a new way to explore and understand the nature of the early universe and the force that holds together ordinary matter, research at RHIC has revealed stunning

13

DOE/EIS-0157-SA-01; Supplement Analysis for Continued Operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Analysis Analysis S-1 March 1999 Findings ♦ This supplement analysis evaluated a set of new and modified projects and proposals and other new information and concluded that no supplementation of the 1992 EIS/EIR for Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratories (SNL), Livermore, is needed. Either the projected impacts are within the bounds of the 1992 EIS/EIR, the impacts were anticipated by mitigation measures established in the 1992 EIS/EIR, or the incremental differences in impacts are not significant. ♦ While proposed increases in administrative limits for radioactive materials at LLNL might slightly increase radiological releases during accidents, the resulting consequences are expected to remain essentially the same as described in the 1992

14

Analysis of the BATSE Continuous MER data  

E-Print Network (OSTI)

The CGRO/BATSE database includes many types of data such as the 16-channel continuous background or medium energy resolution burst data (CONT and MER data types). We have calculated some four hundred burst's medium energy resolution spectra and Principal Component Analysis has been applied. We found five components can describe GRBs' spectra.

P. Veres; I. Horvath; L. G. Balazs

2005-10-11T23:59:59.000Z

15

Continuity of Operations (COOP) Implementation Plan | U.S. DOE...  

Office of Science (SC) Website

methods to safeguard personnel, records, and facilities, and ensures the capability to conduct functions at an office of convenience, Alternate Operating Facility (AOF), or...

16

EIS-0225: Continued Operation of the Pantex Plant and Associated Storage of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

25: Continued Operation of the Pantex Plant and Associated 25: Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapon Components EIS-0225: Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapon Components Summary This EIS evaluates the potential environemental impact of a proposal to continue operation of the Pantex Plant and associated storage of nuclear weapon components. Alternatives considered include: (1) Continuing nuclear weapon operations involving assembly and disassembly of nuclear weapons at the Pantex Plant; (2) implementing facility projects, including upgrades and construction consistent with conducting these operations; and (3) continuing to provide interim pit storage at the Pantex Plant and increasing the storage level from 12,000 to 20,000 pits.

17

EIS-0380: Site-Wide Environmental Impact Statement for Continued Operation of the Los Alamos National Laboratory, New Mexico  

Energy.gov (U.S. Department of Energy (DOE))

This Site-Wide EIS evaluates the continued operation of the Los Alamos National Laboratory (LANL). NNSA identified and assessed three alternatives for continued operation of LANL: (1) No Action, (2) Reduced Operations, and (3) Expanded Operations.

18

EIS-0238: Continued Operation of the Los Alamos National Laboratory, Los  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

238: Continued Operation of the Los Alamos National 238: Continued Operation of the Los Alamos National Laboratory, Los Alamos, New Mexico EIS-0238: Continued Operation of the Los Alamos National Laboratory, Los Alamos, New Mexico Summary This EIS evaluates the potential environmental impacts of a proposal to continue operating the Los Alamos National Laboratory (LANL) located in Los Alamos County, in north-central New Mexico. DOE has identified and assessed four alternatives for the operation of LANL: (1) No Action, (2) Expanded Operations, (3) Reduced Operations, and (4) Greener. Expanded Operations is DOE's Preferred Alternative, with the exception that DOE would only implement pit manufacturing at a level of 20 pits per year. Public Comment Opportunities None available at this time. Documents Available for Download

19

EIS-0380: Site-Wide Environmental Impact Statement for Continued Operation  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

380: Site-Wide Environmental Impact Statement for Continued 380: Site-Wide Environmental Impact Statement for Continued Operation of the Los Alamos National Laboratory, New Mexico EIS-0380: Site-Wide Environmental Impact Statement for Continued Operation of the Los Alamos National Laboratory, New Mexico Summary This Site-Wide EIS evaluates the continued operation of the Los Alamos National Laboratory (LANL). NNSA identified and assessed three alternatives for continued operation of LANL: (1) No Action, (2) Reduced Operations, and (3) Expanded Operations. Public Comment Opportunities No public comment opportunities available at this time. Documents Available for Download May 20, 2013 EIS-0380: Mitigation Action Plan Annual Report Los Alamos National Laboratory Site-Wide Environmental Impact Statement Fiscal Year 2012 Mitigation Action Plan Annual Report

20

Analysis of accidents during flashing operations  

E-Print Network (OSTI)

occurred at intersections under flashing operation compared to those operating in the normal mode. A statistical analysis was conducted to determine the safety of flashing signal operation. No significant increases in accidents or accident severity were...

Obermeyer, Michael Edward

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Local Gaussian operations can enhance continuous-variable entanglement distillation  

E-Print Network (OSTI)

Entanglement distillation is a fundamental building block in long-distance quantum communication. Though known to be useless on their own for distilling Gaussian entangled states, local Gaussian operations may still help to improve non-Gaussian entanglement distillation schemes. Here we show that by applying local squeezing operations, both the performance and the efficiency of existing distillation protocols can be enhanced. We derive the optimal enhancement through local Gaussian unitaries, which can be obtained even in the most natural scenario when Gaussian mixed entangled states are shared after their distribution through a lossy-fiber communication channel.

ShengLi Zhang; Peter van Loock

2011-03-23T23:59:59.000Z

22

Local Gaussian operations can enhance continuous-variable entanglement distillation  

SciTech Connect

Entanglement distillation is a fundamental building block in long-distance quantum communication. Though known to be useless on their own for distilling Gaussian entangled states, local Gaussian operations may still help to improve non-Gaussian entanglement distillation schemes. Here we show that by applying local squeezing operations both the performance and the efficiency of existing distillation protocols can be enhanced. We find that such an enhancement through local Gaussian unitaries can be obtained even when the initially shared Gaussian entangled states are mixed, as, for instance, after their distribution through a lossy-fiber communication channel.

Zhang Shengli; Loock, Peter van [Optical Quantum Information Theory Group, Max Planck Institute for the Science of Light, Guenther-Scharowsky-Strasse 1/Bau 26, DE-91058 Erlangen (Germany); Institute of Theoretical Physics I, Universitaet Erlangen-Nuernberg, Staudtstrasse 7/B2, DE-91058 Erlangen (Germany)

2011-12-15T23:59:59.000Z

23

Operational Analysis of Multiregional Nuclear Reactor Kinetics  

Science Journals Connector (OSTI)

......Operational Analysis of Multiregional Nuclear Reactor Kinetics NASSAR H. S. HAIDAR...analytically for a multiregional nuclear reactor whose subregions are of arbitrary...Operational Analysis of Multiregional Nuclear Reactor Kinetics NASSAU H. S. HAIDAR......

NASSAR H. S. HAIDAR

1983-05-01T23:59:59.000Z

24

ANALYTICAL PARAMETRIC CYCLE ANALYSIS OF CONTINUOUS ROTATING DETONATION  

E-Print Network (OSTI)

ANALYTICAL PARAMETRIC CYCLE ANALYSIS OF CONTINUOUS ROTATING DETONATION EJECTOR-AUGMENTED ROCKET. Donald Wilson for showing me how interesting the topic of continuous detonation is for the application to thank Eric Braun for providing some insights and advice on the physics of continuous detonation. His

Texas at Arlington, University of

25

EIS-0348: Continued Operation of Lawrence Livermore National Laboratory and Supplement Stockpile Stewardship and Management  

Energy.gov (U.S. Department of Energy (DOE))

This EIS analyzes DOE's decision to continue operation of Lawrence Livermore National Laboratory (LLNL) is critical to National Nuclear Security Administration’s Stockpile Stewardship Program and to preventing the spread and use of nuclear weapons worldwide.

26

Nonlinearity and noise modeling of operational transconductance amplifiers for continuous time analog filters  

E-Print Network (OSTI)

A general framework for performance optimization of continuous-time OTA-C (Operational Transconductance Amplifier-Capacitor) filters is proposed. Efficient procedures for evaluating nonlinear distortion and noise valid for any filter of arbitrary...

Ramachandran, Arun

2006-08-16T23:59:59.000Z

27

Analysis Paralysis-Developing A Business Continuity Plan  

E-Print Network (OSTI)

years · Built Bombs at Rocky Flats for 9 years · UCAR/ NCAR: ­ Safety Director ­ Event ServicesAnalysis Paralysis-Developing A Business Continuity Plan Steve Sadler, UCAR Director of Safety and Site Services #12;Getting to Know A Business Continuity Survivor · Health, Environment and Safety

28

EIS-0426: Site-Wide Environmental Impact Statement for Continued Operation  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6: Site-Wide Environmental Impact Statement for Continued 6: Site-Wide Environmental Impact Statement for Continued Operation of the Department of Energy / National Nuclear Security Administration Nevada National Security Site and Off-Site Locations in the State of Nevada EIS-0426: Site-Wide Environmental Impact Statement for Continued Operation of the Department of Energy / National Nuclear Security Administration Nevada National Security Site and Off-Site Locations in the State of Nevada Summary This Site-Wide EIS evaluates the potential environmental impacts of proposed alternatives for continued management and operation of the Nevada National Security Site (NNSS) (formerly known as the Nevada Test Site) and other U.S. Department of Energy/National Nuclear Security Administration (DOE/NNSA)-managed sites in Nevada.

29

Project Analysis Standard Operating Procedure  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

EVM project analysis is to provide consistent and timely insight to project status in order to enable timely, effective management decisions. In conjunction with conducting...

30

Tank Farm Operations Surveillance Automation Analysis  

SciTech Connect

The Nuclear Operations Project Services identified the need to improve manual tank farm surveillance data collection, review, distribution and storage practices often referred to as Operator Rounds. This document provides the analysis in terms of feasibility to improve the manual data collection methods by using handheld computer units, barcode technology, a database for storage and acquisitions, associated software, and operational procedures to increase the efficiency of Operator Rounds associated with surveillance activities.

MARQUEZ, D.L.

2000-12-21T23:59:59.000Z

31

Modal Analysis for Grid Operation  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Presenter: Ning Zhou Pacific Northwest National Laboratory ning.zhou@pnnl.gov 27/28 June 2013 Washington, DC DOE/OE Transmission Reliability Program Past Oscillation Event - 1996/08/10 [bitmap version 1100 1200 1300 1400 1500 15:42:03 15:48:51 15:47:36 Power (MW) August 10, 1996 Western Power System Breakup California-Oregon Intertie Time Domain ~ -3.1% < ~3.5% Damping ~ 8.4% Early Warning ~6 minutes Freq Domain Project Objective  Ways to Improve Damping - Power System Stabilizer (PSS): parameters pre-tuned based on off-line scenarios - Reactive Support: locations pre-selected based on off-line scenarios - Adjustment of Operator Controllable Variables : operator actions determined with the on-line scenarios  Objective of this Project:

32

Employee Job Task Analysis (EJTA) PIA, Richland Operations Office...  

NLE Websites -- All DOE Office Websites (Extended Search)

Employee Job Task Analysis (EJTA) PIA, Richland Operations Office Employee Job Task Analysis (EJTA) PIA, Richland Operations Office Employee Job Task Analysis (EJTA) PIA, Richland...

33

Justification for Continued Operation of the SRS Saltstone Facility (Z-Area)  

SciTech Connect

Saltstone Production and Disposal Facilities (Z-Area) are a part of the Defense Waste Processing Facilities (DWPF). Z-Area facilities are just one segment of an integrated waste management and disposal system located at the Savannah River Site (SRS). The bases for the Justification of Continuing Operations (JCO) of the Saltstone Production and Disposal Facilities (Z-Area) at SRS are provided.

Wagner, W.A.

1999-01-20T23:59:59.000Z

34

THE BISHOP-PHELPS-BOLLOBAS PROPERTY FOR OPERATORS BETWEEN SPACES OF CONTINUOUS FUNCTIONS  

E-Print Network (OSTI)

THE BISHOP-PHELPS-BOLLOB´AS PROPERTY FOR OPERATORS BETWEEN SPACES OF CONTINUOUS FUNCTIONS MAR´IA D accurate version of the above theorem. In 2008, M. D. Acosta, R. M. Aron, D. Garc´ia and M. Maestre by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded

Martín, Miguel

35

EIS-0157: Site-wide for Continued Operation of Lawrence Livermore/Sandia National Laboratory, Livermore  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy prepared this environmental impact statement to analyze the potential environmental impacts of the continued operation of Lawrence Livermore National Laboratory and Sandia National Laboratory - Livermore, including programmatic enhancements and facility modifications to occur over the subsequent 10-year term that are pursuant to research and development missions established for the Laboratories by Congress and the President.

36

Graphical description of local Gaussian operations for continuous-variable weighted graph states  

E-Print Network (OSTI)

The form of a local Clifford (LC, also called local Gaussian (LG)) operation for the continuous-variable (CV) weighted graph states is presented in this paper, which is the counterpart of the LC operation of local complementation for qubit graph states. The novel property of the CV weighted graph states is shown, which can be expressed by the stabilizer formalism. It is distinctively different from the qubit weighted graph states, which can not be expressed by the stabilizer formalism. The corresponding graph rule, stated in purely graph theoretical terms, is described, which completely characterizes the evolution of CV weighted graph states under this LC operation. This LC operation may be applied repeatedly on a CV weighted graph state, which can generate the infinite LC equivalent graph states of this graph state. This work is an important step to characterize the LC equivalence class of CV weighted graph states.

Jing Zhang

2008-10-08T23:59:59.000Z

37

Development of a hybrid margin angle controller for HVDC continuous operation  

SciTech Connect

The objective of this paper is to present a new hybrid margin angle control method for HVDC continuous operation under AC system fault conditions. For stable continuous operation of HVDC systems, the margin angle controller must be designed to maintain the necessary margin angle to avoid commutation failures. The proposed method uses the open loop margin angle controller (MAC) as the basic controller, and adds output from the closed loop MAC to correct the control angle. A fast voltage detection algorithm is used for open loop control, and margin angle reference correction using harmonics detection for closed loop control are also developed. The combination of open and closed loop control provides quick responses when faults occur with stable and speedy recovery after fault clearance. The effectiveness of the developed controller is confirmed through EMTP digital simulations and also with the experiments using an analogue simulator.

Sato, M. [Kansai Electric Power Co., Osaka (Japan)] [Kansai Electric Power Co., Osaka (Japan); Yamaji, K. [Shikoku Electric Power Co., Takamatsu (Japan)] [Shikoku Electric Power Co., Takamatsu (Japan); Sekita, M. [Electric Power Development Co., Tokyo (Japan)] [Electric Power Development Co., Tokyo (Japan); Amano, M.; Nishimura, M.; Konishi, H.; Oomori, T. [Hitachi, Ltd. (Japan)] [Hitachi, Ltd. (Japan)

1996-11-01T23:59:59.000Z

38

Mitigation Monitoring and Reporting Program for continued operation of Lawrence Livermore National Laboratory  

SciTech Connect

A Mitigation Monitoring and Reporting Program, required by the California Environmental Quality Act, was developed by UC as part of the Final EIS/EIR process. This document describing the program is a companion to the Final Environmental Impact Statement/Environmental Impact Report (EIS/EIR) for the Continued Operation of Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratories, Livermore (SNL, Livermore). The Final EIS/EIR analyzes the potential environmental impacts of the proposed action, which for the purposes of NEPA is: continued operation, including near-term (within 5 to 1 0 years) proposed projects, of LLNL and SNL, Livermore. The proposed action for the EIR is the renewal of the contract between DOE and UC for UC`s continued operation and management of LLNL. The Mitigation Monitoring and Reporting Program is for implementing and monitoring progress of measures taken to mitigate the significant impacts of the proposed action. A complete description of the impacts and proposed mitigations is in Section 5 of Volume I of the Final EIS/EIR. This report summarizes the mitigation measures, identifies the responsible party at the Laboratory for implementing the mitigation measure, states when monitoring will be implemented, when the mitigation measure will be in place and monitoring completed, and who will verify that the mitigation measure was implemented.

Not Available

1992-08-01T23:59:59.000Z

39

Hazard Analysis Reports for Nuclear Explosive Operations  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NA-STD-3016-2006 NA-STD-3016-2006 May 2006 DOE LIMITED STANDARD HAZARD ANALYSIS REPORTS FOR NUCLEAR EXPLOSIVE OPERATIONS U.S. Department of Energy AREA SAFT Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. NOT MEASUREMENT SENSITIVE ii Available on the Department of Energy Technical Standards Program web site at http://www.eh.doe.gov/techstds/ DOE-NA-STD-3016-2006 iii FORWARD This Department of Energy (DOE)/National Nuclear Security Administration (NNSA) technical standard is approved for use by the Assistant Deputy Administrator for Military Application and Stockpile Operations (NA-12), and is available for use to prepare Nuclear Explosive Operation (NEO) Hazard Analysis Reports (HARs) as required by 10 CFR 830, "Nuclear Safety Management." This Standard is

40

EIS-0238-S1: Supplemental Environmental Impact Statement to the Final Site-Wide Environmental Impact Statement for Continued Operation of the Los Alamos National Laboratory, New Mexico  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy (DOE), Albuquerque Operations Office, has prepared a Supplemental Analysis (SA) to determine if the Site-Wide Environmental Impact Statement for Continued Operations of Los Alamos National Laboratory (SWEIS) adequately addresses the environmental effects of a proposal for modifying current methods utilized to receive and manage certain offsite unwanted radioactive sealed sources at Los Alamos National Laboratory or if additional documentation under the National Environmental Policy Act (NEPA) is needed.

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Room temperature continuous wave operation of quantum cascade lasers with 12.5% wall plug efficiency  

SciTech Connect

An InP based quantum cascade laser heterostructure emitting at 4.6 {mu}m was grown with gas-source molecular beam epitaxy. The wafer was processed into a conventional double-channel ridge waveguide geometry with ridge widths of 19.7 and 10.6 {mu}m without semi-insulating InP regrowth. An uncoated, narrow ridge device with a 4.8 mm cavity length was epilayer down bonded to a diamond submount and exhibits 2.5 W maximum output power with a wall plug efficiency of 12.5% at room temperature in continuous wave operation.

Bai, Y.; Slivken, S.; Darvish, S. R.; Razeghi, M. [Center for Quantum Devices, Department of Electrical Engineering and Computer Science, Northwestern University, Evanston, Illinois 60208 (United States)

2008-07-14T23:59:59.000Z

42

Draft Site-Wide EIS on the Continued Operation of the Los Alamos National Laboratory  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Responsible Agency: U.S. Department of Energy (DOE) Responsible Agency: U.S. Department of Energy (DOE) Cooperating Agency: Incorporated County of Los Alamos Title: Draft Site-Wide Environmental Impact Statement on the Continued Operation of the Los Alamos National Laboratory, Los Alamos, New Mexico Contact: For further information, or to submit comments concerning this Draft Site-Wide Environmental Impact Statement (SWEIS), contact: Corey Cruz, Project Manager U.S. DOE, Albuquerque Operations Office P.O. Box 5400, Albuquerque, NM 87185 Telephone: 1-800-898-6623 Fax: 505-845-6392 For general information on DOE's National Environmental Policy Act (NEPA) process, contact: Carol Borgstrom, Director Office of NEPA Policy and Assistance (EH-42) U.S. DOE, 1000 Independence Avenue, SW, Washington, DC 20585 Telephone: 202-586-4600 or leave a message at 1-800-472-2756

43

Anaerobic digestion of wool scouring wastewater in a digester operated semi-continuously for biomass retention  

Science Journals Connector (OSTI)

An anaerobic digester, operated semi-continuously in order to retain high concentrations of biomass in the digester, was used to treat wool scouring wastewater. At a space load of 9·9 kg COD m?3 day ?1 (hydraulic retention time, 2·8 days) >56% of the COD and >47% of the grease were removed. At these efficiencies, this rate was estimated to be at least 2·5·3· times greater than that which would be achieved in a continuously stirred digester. Preliminary studies of enzymatic pretreatment of the scouring effluent showed that significantly improved treatment rates and/or efficiencies could be achieved—i.e. >70% removal of both the COD and grease at a space load of 12 kg COD m?3 day?1. It is unlikely that any substancial levels of flocculation would develop in this system and it is expected that the moderate use of polyelectrolytes would be required to help maintain the VSS concentration in the reactor.

R.G. Cail; J.P. Barford; R. Lichacz

1986-01-01T23:59:59.000Z

44

Solar bimodal mission and operational analysis  

SciTech Connect

Recent interest by both government and industry has prompted evaluation of a solar bimodal upper stage for propulsion/power applications in Earth orbit. The solar bimodal system provides an integral propulsion and power system for the orbit transfer and on-orbit phases of a satellite mission. This paper presents an initial systems evaluation of a solar bimodal system used to place satellite payloads for Geosynchronous Earth Orbit (GEO), High Earth Orbit (HEO-Molniya class), and Mid Earth Orbit (GPS class) missions with emphasis on the GEO mission. The analysis was performed as part of the Operational Effectiveness and Cost Comparison Study (OECS) sponsored by Phillips Laboratory (PL). The solar bimodal concept was investigated on a mission operational and performance basis for on-orbit power levels ranging from less than 1 kWe to 20 kWe. Atlas IIAS, Delta 7920, and Titan IV launch vehicles were considered for injecting the solar bimodal upper stage and payload into initial orbits ranging from Low Earth Orbit (LEO) (185{times}185 km circular) to higher apogee altitudes (185{times}18,500 km elliptical). The influences of engine thrust, power level, trip time, staging altitude, and thermal storage charge-discharge characteristics on the mission payload capability were developed. {copyright} {ital 1996 American Institute of Physics.}

Frye, P. [Rockwell Aerospace, Rocketdyne Division, Canoga Park, California (United States); Law, G. [The Aerospace Corporation, El Segundo, California (United States)

1996-03-01T23:59:59.000Z

45

Environmental Impact Statement and Environmental Impact Report for Continued Operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Summary-1992.html[6/24/2011 3:44:58 PM] Summary-1992.html[6/24/2011 3:44:58 PM] EXECUTIVE SUMMARY The U.S. Department of Energy (DOE) and the Regents of the University of California (UC) propose the continued operation, including near-term (within 5 to 10 years) proposed projects, of the Lawrence Livermore National Laboratory (LLNL). In addition, DOE proposes the continued operation, including near-term proposed projects, of Sandia National Laboratories, Livermore (SNL, Livermore). Continued operation plus proposed projects at the two Laboratories is needed so that the research and development missions established by Congress and the President can continue to be supported. As provided and encouraged by the National Environmental Policy Act (NEPA) and the California Environmental Quality Act (CEQA), DOE and UC have prepared this document as a joint Environmental Impact Statement (EIS) and

46

Motor current signature analysis for determining operational readiness of motor-operated valves (MOVs)  

SciTech Connect

Motor current signature analysis (MCSA) is a novel diagnostic process for condition monitoring of electric-motor-driven mechanical equipment (e.g., pumps, motor-operated valves, compressors, and processing machinery). The MCSA process identifies, characterizes, and trends over time the instantaneous load variations of mechanical equipment in order to diagnose changes in the condition of the equipment (e.g., due to degradation or service wear), which, if allowed to continue, may lead to failure. It monitors the instantaneous variations (noise content) in the electric current flowing through the power leads to the electric motor that drives the equipment. The motor itself thereby acts as a transducer, sensing both large and small, long-term and rapid, mechanical load variations and converting them to variations in the induced current generated in the motor windings. This motor current noise signature is detected, amplified, and further processed as needed to examine its time domain and frequency domain (spectral) characteristics. The operational principles of MCSA and the nonintrusive data collection apparatus and procedure used with MOVs will be described. Data collected from MOVs in both laboratory and in-plant environments will also be shown to illustrate the ability of MCSA to ''see'' the detailed inner workings of the valve and operator and thus to detect degraded performance at an incipient stage. (Set of 18 vugraphs)

Kryter, R.C.; Haynes, H.D.

1987-01-01T23:59:59.000Z

47

An analysis of nuclear power plant operating costs: A 1995 update  

SciTech Connect

Over the years real (inflation-adjusted) O&M cost have begun to level off. The objective of this report is to determine whether the industry and NRC initiatives to control costs have resulted in this moderation in the growth of O&M costs. Because the industry agrees that the control of O&M costs is crucial to the viability of the technology, an examination of the factors causing the moderation in costs is important. A related issue deals with projecting nuclear operating costs into the future. Because of the escalation in nuclear operating costs (and the fall in fossil fuel prices) many State and Federal regulatory commissions are examining the economics of the continued operation of nuclear power plants under their jurisdiction. The economics of the continued operation of a nuclear power plant is typically examined by comparing the cost of the plants continued operation with the cost of obtaining the power from other sources. This assessment requires plant-specific projections of nuclear operating costs. Analysts preparing these projections look at past industry-wide cost trends and consider whether these trends are likely to continue. To determine whether these changes in trends will continue into the future, information about the causal factors influencing costs and the future trends in these factors are needed. An analysis of the factors explaining the moderation in cost growth will also yield important insights into the question of whether these trends will continue.

NONE

1995-04-21T23:59:59.000Z

48

Columbia River System Operation Review : Final Environmental Impact Statement, Appendix T (Second Continued Volume): Comments & Responses.  

SciTech Connect

This is Appendix T (second continued volume) giving public comments and responses to the final environmental impact statement for the Columbia River System.

Columbia River System Operation Review (U.S.)

1995-11-01T23:59:59.000Z

49

Wavelet based analysis of circuit breaker operation  

E-Print Network (OSTI)

to operate at all. M H Yard DC + Yard DC _ Control DC + Control DC _ 52X TC CC 52Y Close Initiate Trip Initiate 52a 52Y/a 52a 52Y/b 52X/a 52Y/b 9 Coming from an operator in the control house, SCADA, relay, or other source...

Ren, Zhifang Jennifer

2004-09-30T23:59:59.000Z

50

Simulation on Operating Conditions of Chemical Looping Combustion of Methane in a Continuous Bubbling Fluidized-Bed Process  

Science Journals Connector (OSTI)

Simulation on Operating Conditions of Chemical Looping Combustion of Methane in a Continuous Bubbling Fluidized-Bed Process ... Lyon, R. K.; Cole, J. A. Combust. ... Industrial & Engineering Chemistry Research (1996), 35 (7), 2469-2472 CODEN: IECRED; ISSN:0888-5885. ...

Djamila Brahimi; Jeong-Hoo Choi; Pil Sang Youn; Young-Wook Jeon; Sang Done Kim; Ho-Jung Ryu

2012-01-04T23:59:59.000Z

51

EIS-0147: Continued Operation of the K-,L-, and P- Reactors, Savannah River Site, Aiken, South Carolina  

Energy.gov (U.S. Department of Energy (DOE))

This environmental impact statement (EIS) analyzes the environmental impacts of the proposed action, which is to continue operation of K-, L-, and P-Reactors at the Savannah River Site (SRS) to ensure the capability to produce nuclear materials, and to produce nuclear materials as necessary for United States defense and nondefense programs.

52

On the operator action analysis to reduce operational risk in research reactors  

Science Journals Connector (OSTI)

Abstract Human errors during operation and the resulting increase in operational risk are major concerns for nuclear reactors, just as they are for all industries. Additionally, human reliability analysis together with probabilistic risk analysis is a key element in reducing operational risk. The purpose of this paper is to analyze human reliability using appropriate methods for the probabilistic representation and calculation of human error to be used alongside probabilistic risk analysis in order to reduce the operational risk of the reactor operation. We present a technique for human error rate prediction and standardized plant analysis risk. Human reliability methods have been utilized to quantify different categories of human errors, which have been applied extensively to nuclear power plants. The Tehran research reactor is selected here as a case study, and after consultation with reactor operators and engineers human errors have been identified and adequate performance shaping factors assigned in order to calculate accurate probabilities of human failure.

Ramin Barati; Saeed Setayeshi

2014-01-01T23:59:59.000Z

53

Alternative fulfillment operations and vendor analysis  

E-Print Network (OSTI)

This thesis describes the development of quantitative methods to strategically plan the SKU make-up and operational aspects of Amazon's Alternative Fulfillment Sites (AFS). AFSs are smaller Fulfillment Centers (FCs) that ...

Ogundele, Tope (Temitope)

2013-01-01T23:59:59.000Z

54

Sketch Map Analysis Using GIS Buffer Operation  

Science Journals Connector (OSTI)

We developed a method to analyze sketch maps by GIS, and applied it to an actual case ... using buffer operation was more effective for sketch map analyses than other methods, such as the ... micro-genetic cognit...

Kohei Okamoto; Kei-ichi Okunuki…

2005-01-01T23:59:59.000Z

55

Statistical pert analysis using integral operators  

E-Print Network (OSTI)

of Optimization Algorithm. IV CONCLUSIONS AND SUMMARY. 23 25 27 BIBLIOGRAPHY' 29 VITA. 30 vi LIST OF FIGURES Figure Page 2. 1 Activities In Parallel. 2. 2 Activities In Series. 2. 3 2. 4 Wheatstone Bridge Double Wheatstone Bridge. 10 10 2. 5...] extended Hartley and Wortham's method by developing integral operators for activities in double wheatstone bridges and in different types of crise-crosses. Ringer [8] also developed integral operators for activities whose completion times...

Ohlendorf, Curtis Gilbert

1969-01-01T23:59:59.000Z

56

A Toolbox of Hamilton-Jacobi Solvers for Analysis of Nondeterministic Continuous and  

E-Print Network (OSTI)

A Toolbox of Hamilton-Jacobi Solvers for Analysis of Nondeterministic Continuous and Hybrid Systems- plications in the analysis of nondeterministic continuous and hybrid sys- tems. Unfortunately, analytic infrastructure. In this paper we describe the first publicly available toolbox for approx- imating the solution

Mitchell, Ian

57

TVA's Shawnee Fossil Plant Unit 6 sets new record for continuous operation  

SciTech Connect

Tennessee Valley Authority's Shawnee Fossil Plant Unit 6 recently set a new 1,093 day continuous run record. The 10 top practices at Shawnee for achieving high performance are discussed.

Peltier, R.

2008-02-15T23:59:59.000Z

58

EIS-0018: Continued Operation of Los Alamos Scientific Laboratory Site, Los Alamos, New Mexico  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy prepared this statement to assesses the potential cumulative environmental impacts associated with current, known future, and continuing activities at the Los Alamos Scientific Laboratory site.

59

The Business and Technical Case for Continuous Commissioning for Enhanced Building Operations  

E-Print Network (OSTI)

2000. 1.1 Where It All Began The CC engineering process was developed by the ESL, starting in 1991. Continuous Comissioning evolved from the comprehensive monitoring and savings verification program for a successful $96 million energy loan...

Verdict, M.

2006-01-01T23:59:59.000Z

60

Motor current signature analysis method for diagnosing motor operated devices  

DOE Patents (OSTI)

A motor current noise signature analysis method and apparatus for remotely monitoring the operating characteristics of an electric motor-operated device such as a motor-operated valve. Frequency domain signal analysis techniques are applied to a conditioned motor current signal to distinctly identify various operating parameters of the motor driven device from the motor current signature. The signature may be recorded and compared with subsequent signatures to detect operating abnormalities and degradation of the device. This diagnostic method does not require special equipment to be installed on the motor-operated device, and the current sensing may be performed at remote control locations, e.g., where the motor-operated devices are used in accessible or hostile environments.

Haynes, Howard D. (Kingston, TN); Eissenberg, David M. (Oak Ridge, TN)

1990-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Assessing the operational life of flexible printed boards intended for continuous flexing applications : a case study.  

SciTech Connect

Through the vehicle of a case study, this paper describes in detail how the guidance found in the suite of IPC (Association Connecting Electronics Industries) publications can be applied to develop a high level of design assurance that flexible printed boards intended for continuous flexing applications will satisfy specified lifetime requirements.

Beck, David Franklin

2011-01-01T23:59:59.000Z

62

A discounted-cost continuous-time flexible manufacturing and operator scheduling model solved by deconvexification over time  

SciTech Connect

A discounted-cost, continuous-time, infinite-horizon version of a flexible manufacturing and operator scheduling model is solved. The solution procedure is to convexify the discrete operator-assignment constraints to obtain a linear program, and then to regain the discreteness and obtain an approximate manufacturing schedule by deconvexification of the solution of the linear program over time. The strong features of the model are the accommodation of linear inequality relations among the manufacturing activities and the discrete manufacturing scheduling, whereas the weak features are intra-period relaxation of inventory availability constraints, and the absence of inventory costs, setup times, and setup charges.

Eaves, B.C.; Rothblum, U.G.

1990-08-01T23:59:59.000Z

63

ATM 1053 I B LSP OPERATIONAL HAZARD ANALYSIS  

E-Print Network (OSTI)

to incorporate those changes in hardware and operations that have occurred since the original release. All identified thro1 ghout the operational life cycle of the LSP Experiments; (1) :Lanufacturing and Assembly, (2 1 thru 5 are provided to clarify the hardware flow. Philosophy - This analysis has been performed

Rathbun, Julie A.

64

Houston LDAR II network: design, operation, and performance analysis  

E-Print Network (OSTI)

HOUSTON LDAR II NETWORK: DESIGN, OPERATION, AND PERFORMANCE ANALYSIS A Dissertation by BRANDON LEE ELY Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree... of DOCTOR OF PHILOSOPHY August 2008 Major Subject: Atmospheric Sciences HOUSTON LDAR II NETWORK: DESIGN, OPERATION, AND PERFORMANCE ANALYSIS A Dissertation by BRANDON LEE ELY Submitted to the Office of Graduate Studies of Texas A...

Ely, Brandon Lee

2008-10-10T23:59:59.000Z

65

Meeting the reactor operator's information needs using functional analysis  

SciTech Connect

Since the accident at Three Mile Island, many ideas have been proposed for assisting the reactor operator during emergency situations. However, some of the suggested remedies do not alleviate an important shortcoming of the TMI control room: the operators were not presented with the information they needed in a manner which would allow prompt diagnosis of the problem. To address this problem, functional analysis is being applied at the LOFT facility to ensure that the operator's information needs are being met in his procedures and graphic displays. This paper summarizes the current applications of functional analysis at LOFT.

Nelson, W.R.; Clark, M.T.

1980-01-01T23:59:59.000Z

66

Volume II - Accident and Operational Safety Analysis Handbook  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

208-2012 208-2012 July 2012 DOE HANDBOOK Accident and Operational Safety Analysis Volume II: Operational Safety Analysis Techniques U.S. Department of Energy Washington, D.C. 20585 NOT MEASUREMENT SENSITIVE DOE-HDBK-1208-2012 i ACKNOWLEDGEMENTS This Department of Energy (DOE) Accident and Operational Safety Analysis Handbook was prepared under the sponsorship of the DOE Office of Health Safety and Security (HSS), Office of Corporate Safety Programs, and the Energy Facility Contractors Operating Group (EFCOG), Industrial Hygiene and Safety Sub-group of the Environmental Health and Safety Working Group. The preparers would like to gratefully acknowledge the authors whose works are referenced in this document, and the individuals who provided valuable technical insights and/or specific

67

Continuous Commissioning®  

E-Print Network (OSTI)

Continuous Commissioning? for Existing Buildings D. E. Claridge, P.E., Ph.D., FASHRAE Professor, Department of Mechanical Engineering Director, Energy Systems Laboratory Continuous Commissioning? and CC? are registered trademarks of the Texas... Commissioning Building Has ? Satisfied Occupants ? Comfortable Conditions ? Operational Issues Resolved ? Operating Staff Trained ? Reduced Operating Cost ? Saving from 10% to 20%+ over baseline total cost ? ROI of 40%+ ? Breakeven investment...

Culp, C.; Claridge, D. E.

2011-01-01T23:59:59.000Z

68

Environmental analysis of the operation of Oak Ridge National Laboratory (X-10 site)  

SciTech Connect

An environmental analysis of the operation of the Oak Ridge National Laboratory (ORNL) facilities in Bethel Valley and Melton Valley was conducted to present to the public information concerning the extent to which recognizable effects, or potential effects, on the environment may occur. The analysis addresses current operations of the ORNL X-10 site and completed operations that may continue to have residual effects. Solid wastes from ORNL operations at the Y-12 site which are transported to the X-10 site for burial (e.g., Biology Division animal wastes) are included as part of X-10 site operation. Socioeconomic effects are associated primarily with the communities where employees live and with the Knoxville Bureau of Economic Analysis economic area as a whole. Therefore, ORNL employees at both Y-12 and X-10 sites are included in the ORNL socioeconomic impact analysis. An extensive base of environmental data was accumulated for this report. Over 80 reports related to ORNL facilities and/or operations are cited as well as many open-literature citations. Environmental effects of the operation of ORNL result from operational discharges from the onsite facilities; construction and/or modification of facilities, transportation to and from the site of persons, goods and services; socioeconomic impacts to the local, regional, and general population; and accidental discharges if they should occur. Operational discharges to the environnment are constrained by federal, state, and local regulations and by criteria established by the US Department of Energy to minimize adverse impacts. It is the purpose of this document to evaluate the operation of the ORNL insofar as impacts beyond the site boundary may occur or have the potential for occurrence.

Boyle, J.W.; Blumberg, R.; Cotter, S.J.

1982-11-01T23:59:59.000Z

69

A reliability analysis of electrical power plant operation data  

E-Print Network (OSTI)

A RELIABILITY ANALYSIS QF ELECTRICAL POWER PLANT OPERATION DATA A Thesis by RANDALL KEITH SPQERI Submitted to the Graduate College of Texas A&M University in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE January... 1970 Ma]or Subject: Statistics A RELIABILITY ANALYSIS QF ELECTRICAL POWER PLANT OPERATION DATA A Thesis by RANDALL KEITH SPOERI Approved as to style and content by; (Cha o o itt ) Head of Department) Member) ( ember) January 1970 9:idM9...

Spoeri, Randall Keith

2012-06-07T23:59:59.000Z

70

MANGO – Modal Analysis for Grid Operation: A Method for Damping Improvement through Operating Point Adjustment  

SciTech Connect

Small signal stability problems are one of the major threats to grid stability and reliability in the U.S. power grid. An undamped mode can cause large-amplitude oscillations and may result in system breakups and large-scale blackouts. There have been several incidents of system-wide oscillations. Of those incidents, the most notable is the August 10, 1996 western system breakup, a result of undamped system-wide oscillations. Significant efforts have been devoted to monitoring system oscillatory behaviors from measurements in the past 20 years. The deployment of phasor measurement units (PMU) provides high-precision, time-synchronized data needed for detecting oscillation modes. Measurement-based modal analysis, also known as ModeMeter, uses real-time phasor measurements to identify system oscillation modes and their damping. Low damping indicates potential system stability issues. Modal analysis has been demonstrated with phasor measurements to have the capability of estimating system modes from both oscillation signals and ambient data. With more and more phasor measurements available and ModeMeter techniques maturing, there is yet a need for methods to bring modal analysis from monitoring to actions. The methods should be able to associate low damping with grid operating conditions, so operators or automated operation schemes can respond when low damping is observed. The work presented in this report aims to develop such a method and establish a Modal Analysis for Grid Operation (MANGO) procedure to aid grid operation decision making to increase inter-area modal damping. The procedure can provide operation suggestions (such as increasing generation or decreasing load) for mitigating inter-area oscillations.

Huang, Zhenyu; Zhou, Ning; Tuffner, Francis K.; Chen, Yousu; Trudnowski, Daniel J.; Diao, Ruisheng; Fuller, Jason C.; Mittelstadt, William A.; Hauer, John F.; Dagle, Jeffery E.

2010-10-18T23:59:59.000Z

71

This message has been concurred and approved by the Director of the Emergency Operations Training Academy and by the Continuity Programs Manager  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

66 on DOE 2011 Continuity of Operations (COOP) 66 on DOE 2011 Continuity of Operations (COOP) Awareness Briefing Available to Contractors For each contract requiring or involving responsibility for work or operations at DOE/NNSA sites/facilities that support or perform essential functions/activities that directly support National Essential Functions (NEF), Mission Essential Functions (MEF), Primary Mission Essential Functions (PMEF), or Essential Supporting Activities (ESA), the Contractor Requirements Document (CRD) DOE Order 150.1, Continuity Programs, sets forth the contractor's responsibility to establish and maintain a Continuity of Operations (COOP) program. This CRD requires the contractor and its applicable subcontractors to conduct an annual COOP awareness briefing for all members of its contractor workforce who perform

72

This message has been concurred and approved by the Director of the Emergency Operations Training Academy and by the Continuity Programs Manager  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

to Policy Flash 2010-74 on DOE 2010 Continuity of Operations (COOP) to Policy Flash 2010-74 on DOE 2010 Continuity of Operations (COOP) Awareness Briefing Available to Contractors For each contract requiring or involving responsibility for work or operations at DOE/NNSA sites or facilities that support or perform essential functions/activities that directly support National Essential Functions (NEF), Mission Essential Functions (MEF), Primary Mission Essential Functions (PMEF), or Essential Supporting Activities (ESA) the Contractor Requirements Document (CRD) DOE Order 150.1, Continuity Programs, sets forth the contractor responsibility for a Continuity of Operations (COOP) Program. This CRD requires the contractor and its applicable subcontractors to conduct annual COOP awareness briefing for all its contractor workforce who perform essential functions/activities that directly

73

Sample Business Plan Framework 1: A program seeking to continue operations in the post-grant period as a not-for-profit (NGO) entity  

Energy.gov (U.S. Department of Energy (DOE))

U.S. Department of Energy Better Buildings Neighborhood Program: Sample Business Plan Framework 1: A program seeking to continue operations in the post-grant period as a not-for-profit (NGO) entity.

74

Continuous Energy Management of the HVAC&R System in an Office Building System Operation and Energy Consumption for the Eight Years after Building Completion  

E-Print Network (OSTI)

The authors continuously studied the energy consumption of a heating, ventilating, air- conditioning and refrigerating (HVAC&R) system in an office for the operation of the system in terms of its expected performance. A fault in the system control...

Akashi, Y.; Shinozaki, M.; Kusuda, R.; Ito, S.

2006-01-01T23:59:59.000Z

75

Analysis and Modeling of Ground Operations at Hub Airports  

E-Print Network (OSTI)

constraint in the departure process at busy airports like Boston Logan International airport. For example1 Analysis and Modeling of Ground Operations at Hub Airports Kari Andersson1 , Francis Carr2 , Eric Feron3 and William D. Hall4 Abstract: Building simple and accurate models of hub airports can

Feron, Eric

76

Silicon avalanche photodiode operation and lifetime analysis for small satellites  

E-Print Network (OSTI)

Silicon avalanche photodiodes (APDs) are sensitive to operating temperature fluctuations and are also susceptible to radiation flux expected in satellite-based quantum experiments. We introduce a low power voltage adjusting mechanism to overcome the effects of in-orbit temperature fluctuations. We also present data on the performance of Si APDs after irradiation (gamma-ray and proton beam). Combined with an analysis of expected orbital irradiation, we propose that a Si APD in a 400 km equatorial orbit may operate beyond the lifetime of the satellite.

Tan, Yue Chuan; Cheng, Cliff; Ling, Alexander

2013-01-01T23:59:59.000Z

77

Silicon avalanche photodiode operation and lifetime analysis for small satellites  

E-Print Network (OSTI)

Silicon avalanche photodiodes (APDs) are sensitive to operating temperature fluctuations and are also susceptible to radiation flux expected in satellite-based quantum experiments. We introduce a low power voltage adjusting mechanism to overcome the effects of in-orbit temperature fluctuations. We also present data on the performance of Si APDs after irradiation (gamma-ray and proton beam). Combined with an analysis of expected orbital irradiation, we propose that a Si APD in a 400 km equatorial orbit may operate beyond the lifetime of the satellite.

Yue Chuan Tan; Rakhitha Chandrasekara; Cliff Cheng; Alexander Ling

2013-06-28T23:59:59.000Z

78

Final Environmental Impact Statement and Environmental Impact Report for continued operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore. Executive summary  

SciTech Connect

The US Department of Energy (DOE) and the Regents of the University of California (UC) propose the continued operation, including near-term proposed projects, of the Lawrence Livermore National Laboratory (LLNL). In addition, DOE proposes the continued operation, including near-term proposed projects, of Sandia National Laboratories, Livermore (SNL, Livermore). Continued operation plus proposed projects at the two Laboratories is needed so that the research and development missions established by Congress and the President can continue to be supported. As provided and encouraged by the National Environmental Policy Act (NEPA) and the California Environmental Quality Act (CEQA), DOE and UC have prepared this document as a joint Environmental Impact Statement (EIS) and Environmental Impact Report (EIR) to analyze the impacts of the proposed action. In addition, this document discusses a no action alternative for continuing operations at FY 1992 funding levels without further growth, a modification of operations alternative focused on specific adverse environmental impacts of operations or facilities, and a shutdown and decommissioning alternative. This document also examines the alternative of UC discontinuing its management of LLNL after the current contract expires on September 30, 1992. The environmental documentation process provides information to the public, government agencies, and decision makers about the environmental impacts of implementing the proposed and alternative actions. In addition, this environmental documentation identifies alternatives and possible ways to reduce or prevent environmental impacts. A list of the issues raised through the EIS/EIR scoping process is presented.

Not Available

1992-08-01T23:59:59.000Z

79

Environmental Quality Information Analysis Center (EQIAC) operating procedures handbook  

SciTech Connect

The Operating Procedures Handbook of the Environmental Quality Information Analysis Center (EQIAC) is intended to be kept current as EQIAC develops and evolves. Its purpose is to provide a comprehensive guide to the mission, infrastructure, functions, and operational procedures of EQIAC. The handbook is a training tool for new personnel and a reference manual for existing personnel. The handbook will be distributed throughout EQIAC and maintained in binders containing current dated editions of the individual sections. The handbook will be revised at least annually to reflect the current structure and operational procedures of EQIAC. The EQIAC provides information on environmental issues such as compliance, restoration, and environmental monitoring do the Air Force and DOD contractors.

Walsh, T.E. (Florida Univ., Gainesville, FL (United States)); Das, S. (Oak Ridge National Lab., TN (United States))

1992-08-01T23:59:59.000Z

80

Analysis of the structural continuity in twinned crystals in terms of pseudo-eigensymmetry of crystallographic orbits  

Science Journals Connector (OSTI)

A general approach to the analysis of structural continuity in twins is presented and applied to the known twins in melilite.

Marzouki, M.A.

2013-10-18T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

An analysis of repository waste-handling operations  

SciTech Connect

This report has been prepared to document the operational analysis of waste-handling facilities at a geologic repository for high-level nuclear waste. The site currently under investigation for the geologic repository is located at Yucca Mountain, Nye County, Nevada. The repository waste-handling operations have been identified and analyzed for the year 2011, a steady-state year during which the repository receives spent nuclear fuel containing the equivalent of 3000 metric tons of uranium (MTU) and defense high-level waste containing the equivalent of 400 MTU. As a result of this analysis, it has been determined that the waste-handling facilities are adequate to receive, prepare, store, and emplace the projected quantity of waste on an annual basis. In addition, several areas have been identified where additional work is required. The recommendations for future work have been divided into three categories: items that affect the total waste management system, operations within the repository boundary, and the methodology used to perform operational analyses for repository designs. 7 refs., 48 figs., 11 tabs.

Dennis, A.W.

1990-09-01T23:59:59.000Z

82

Continued Evaluation of the Pulse-Echo Ultrasonic Instrument for Critical Velocity Determination during Hanford Tank Waste Transfer Operations  

SciTech Connect

Laboratory (PNNL) conducted an extensive evaluation of the ability of three ultrasonic instruments to detect critical velocity for a broad range of simulated Hanford nuclear waste streams containing particles with mean particle sizes of >50 microns. Evaluations were perform using the pipe loop at the Process Development Laboratory – East (PDL-E) at PNNL that was designed and built to evaluate the pipeline plugging issue during slurry transfer operations at the Hanford Waste Treatment Plant. In 2011 the ability of the ultrasonic PulseEcho system to detect critical velocity continued to be evaluated using the PDL-E flow loop and new simulants containing high-density particles with a mean particle size of < 15 microns. The PDL-E flow loop was modified for the 2011 testing to include a new test section that contained 5-MHz and 10-MHz ultrasonic transducers non-invasively mounted to schedule 40 pipe. The test section also contained reference instrumentation to facilitate direct comparison of the real-time PulseEcho transducer responses with experimentally observed critical velocities. This paper presents the results from the 2011 PulseEcho evaluation using a variety of simulated Hanford nuclear waste streams that were selected to encompass the expected high-level waste feed properties.

Denslow, Kayte M.; Bontha, Jagannadha R.; Adkins, Harold E.; Jenks, Jeromy WJ; Burns, Carolyn A.; Schonewill, Philip P.; Hopkins, Derek F.; Thien, Michael G.; Wooley, Theodore A.

2012-04-01T23:59:59.000Z

83

Job Task Analysis: Building Operations Professional; February - December 2014  

SciTech Connect

This report describes the process for and results of a comprehensive job task analysis of Building Operations Professionals. This study was performed by Professional Testing on behalf of the National Renewable Energy Laboratory (NREL). The competency (domains, tasks and associated knowledge) list, which defines the work performed by practitioners, was initially developed by a representative panel of practitioners during a meeting held on February 10-12, 2014 in Orlando Florida. Following the identification of the job tasks and associated knowledge and skills, a validation survey was conducted of the finding of the JTA and the results of the validation study were reviewed by a representative panel of practitioners during a conference call held on May 30, 2014. The committee finalized the JTA and examination blueprints for the Building Operations Professional credential scheme based on the survey results.

Woodley, C. D.

2015-01-01T23:59:59.000Z

84

Continuity Programs  

Directives, Delegations, and Requirements

The order provides requirements and responsibilities to ensure that the Department is ready to respond promptly, efficiently, and effectively to a continuity event involving facilities, activities, or operations. Cancels DOE O 150.1.

2014-03-31T23:59:59.000Z

85

Continuity Programs  

Directives, Delegations, and Requirements

The order provides requirements and responsibilities to ensure that the Department is ready to respond promptly, efficiently, and effectively to a continuity event involving facilities, activities, or operations. No cancellation. Canceled by DOE O 150.1A.

2008-05-08T23:59:59.000Z

86

Final Site-Wide Environmental Impact Statement for the Continued Operation of the Los Alamos National Laboratory, Los Alamos, New Mexico (05/2008)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2 2 Section 3 (pages 3-562 through 3-1089) and Section 4 Final Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory, Los Alamos, New Mexico DOE/EIS-0380 May 2008 Reader's Guide This Comment Response Document (CRD) for the Final Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory, Los Alamos, New Mexico (LANL SWEIS or SWEIS) consists of four sections: * Chapter 1 - Overview of the Public Comment Process This section describes the public comment process for the Draft LANL SWEIS; the format

87

Final Site-Wide Environmental Impact Statement for the Continued Operation of the Los Alamos National Laboratory, Los Alamos, New Mexico (05/2008)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2 * Book 1 2 * Book 1 Appendices A through H Final Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory, Los Alamos, New Mexico DOE/EIS-0380 May 2008 iii COVER SHEET Responsible Agency: U.S. Department of Energy (DOE) National Nuclear Security Administration (NNSA) Title: Final Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory, Los Alamos, New Mexico (SWEIS) (DOE/EIS-0380) Location: Los Alamos, New Mexico For additional information or for copies of the SWEIS, contact: Elizabeth Withers, EIS Document Manager NNSA Service Center - Albuquerque

88

Final Site-Wide Environmental Impact Statement for the Continued Operation of the Los Alamos National Laboratory, Los Alamos, New Mexico (05/2008)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 1 Sections 1, 2, and 3 (pages 3-1 through 3-561) Final Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory, Los Alamos, New Mexico DOE/EIS-0380 May 2008 Reader's Guide This Comment Response Document (CRD) for the Final Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory, Los Alamos, New Mexico (LANL SWEIS or SWEIS) consists of four sections: * Chapter 1 - Overview of the Public Comment Process This section describes the public comment process for the Draft LANL SWEIS; the format

89

Hazardous-waste analysis plan for LLNL operations  

SciTech Connect

The Lawrence Livermore National Laboratory is involved in many facets of research ranging from nuclear weapons research to advanced Biomedical studies. Approximately 80% of all programs at LLNL generate hazardous waste in one form or another. Aside from producing waste from industrial type operations (oils, solvents, bottom sludges, etc.) many unique and toxic wastes are generated such as phosgene, dioxin (TCDD), radioactive wastes and high explosives. One key to any successful waste management program must address the following: proper identification of the waste, safe handling procedures and proper storage containers and areas. This section of the Waste Management Plan will address methodologies used for the Analysis of Hazardous Waste. In addition to the wastes defined in 40 CFR 261, LLNL and Site 300 also generate radioactive waste not specifically covered by RCRA. However, for completeness, the Waste Analysis Plan will address all hazardous waste.

Roberts, R.S.

1982-02-12T23:59:59.000Z

90

FREEWAY PERFORMANCE MEASUREMENT SYSTEM (PeMS): AN OPERATIONAL ANALYSIS TOOL  

E-Print Network (OSTI)

and calibrate simulation models. The paper describes the use of PeMS in conducting operational analysis from case studies on conducting freeway operational analyses, bottleneck identification, Level and researchers in conducting freeway operational analyses, bottleneck identification, determining the Level

Varaiya, Pravin

91

Safety analysis, 200 Area, Savannah River Plant: Separations area operations  

SciTech Connect

The nev HB-Line, located on the fifth and sixth levels of Building 221-H, is designed to replace the aging existing HB-Line production facility. The nev HB-Line consists of three separate facilities: the Scrap Recovery Facility, the Neptunium Oxide Facility, and the Plutonium Oxide Facility. There are three separate safety analyses for the nev HB-Line, one for each of the three facilities. These are issued as supplements to the 200-Area Safety Analysis (DPSTSA-200-10). These supplements are numbered as Sup 2A, Scrap Recovery Facility, Sup 2B, Neptunium Oxide Facility, Sup 2C, Plutonium Oxide Facility. The subject of this safety analysis, the, Plutonium Oxide Facility, will convert nitrate solutions of {sup 238}Pu to plutonium oxide (PuO{sub 2}) powder. All these new facilities incorporate improvements in: (1) engineered barriers to contain contamination, (2) barriers to minimize personnel exposure to airborne contamination, (3) shielding and remote operations to decrease radiation exposure, and (4) equipment and ventilation design to provide flexibility and improved process performance.

Perkins, W.C.; Lee, R.; Allen, P.M.; Gouge, A.P.

1991-07-01T23:59:59.000Z

92

Operating Experience and Teardown Analysis for Engines Operated on Biodiesel Blends (B20)  

SciTech Connect

In this study, eight engines and fuel systems were removed from trucks operating on B20 or diesel. Results indicate little difference in operational and maintenance costs between the B20- and diesel.

Fraer, R.; Dinh, H.; Proc, K.; McCormick, R. L.; Chandler, K.; Buchholz, B.

2005-11-01T23:59:59.000Z

93

Final Environmental Impact Statement and Environmental Impact Report for continued operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore. Volume 4, Comments and responses  

SciTech Connect

This Environmental Impact Statement/Environmental Impact Report (EIS/EIR) is prepared pursuant to the National Environmental Policy Act (NEPA) and the California Environmental Quality Act (CEQA). This document analyzes the potential environmental impacts of the proposed action: continued operation, including near-term (within 5 to 10 years) proposed projects, of Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratories, Livermore (SNL, Livermore). Additionally, this document analyzes a no action alternative involving continuing operations at FY 1992 funding levels without further growth, a modification of operations alternative to reduce adverse environmental impacts of operations or facilities, and a shutdown and decommissioning alternative of UC discontinuing its management of LLNL after the current contract expires on September 30, 1992. This document assesses the environmental impacts of the Laboratories` operations on air and water quality, geological and ecological systems, occupational and public health risks, prehistoric and historic resources, endangered species, floodplains and wetlands, socioeconomic resources, hazardous waste management, site contamination, and other environmental issues. The EIS/EIR is divided into five volumes and two companion reports. This volume contains copies of the written comments and transcripts of individual statements at the public hearing and the responses to them.

Not Available

1992-08-01T23:59:59.000Z

94

Final Environmental Impact Statement and Environmental Impact Report for continued operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore. Volume 1, Text  

SciTech Connect

This Environmental Impact Statement/Environmental Impact Report (EIS/EIR) is prepared pursuant to the National Environmental Policy Act (NEPA) and the California Environmental Quality Act (CEQA). This document analyzes the potential environmental impacts of the proposed action: continued operation, including near-term (within 5 to 10 years) proposed projects, of Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratories, Livermore (SNL, Livermore). Additionally, this document analyzes a no action alternative involving continuing operations at FY 1992 funding levels without further growth, a modification of operations alternative to reduce adverse environmental impacts of operations or facilities, and a shutdown and decommissioning alternative of UC discontinuing its management of LLNL after the current contract expires on September 30, 1992. This document assesses the environmental impacts of the Laboratories` operations on air and water quality, geological and ecological systems, occupational and public health risks, prehistoric and historic resources, endangered species, floodplains and wetlands, socioeconomic resources, hazardous waste management, site contamination, and other environmental issues. The EIS/EIR is divided into five volumes and two companion reports. This volume contains the Final EIS/EIR, which in part relies on the detailed information in the appendices, and comprehensively discusses the proposed action, the alternatives, and the existing conditions and impacts of the proposed action and the alternatives.

Not Available

1992-08-01T23:59:59.000Z

95

Final Environmental Impact Statement and Environmental Impact Report for continued operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore. Volume 3, Appendices F--M  

SciTech Connect

This Environmental Impact Statement/Environmental Impact Report (EIS/EIR) is prepared pursuant to the National Environmental Policy Act (NEPA) and the California Environmental Quality Act (CEQA). This document analyzes the potential environmental impacts of the proposed action: continued operation, including near-term (within 5 to 10 years) proposed projects, of Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratories, Livermore (SNL, Livermore). Additionally, this document analyzes a no action alternative involving continuing operations at FY 1992 funding levels without further growth, a modification of operations alternative to reduce adverse environmental impacts of operations or facilities, and a shutdown and decommissioning alternative of UC discontinuing its management of LLNL after the current contract expires on September 30, 1992. This document assesses the environmental impacts of the Laboratories` operations on air and water quality, geological and ecological systems, occupational and public health risks, prehistoric and historic resources, endangered species, floodplains and wetlands, socioeconomic resources, hazardous waste management, site contamination, and other environmental issues. The EIS/EIR is divided into five volumes and two companion reports. This volume contains the Final EIS/EIR technical appendices F through M. Appendix L has been revised to reflect public information activities since publication of the Draft EIS/EIR. These appendices provide technical support for the analyses in Volume 1 and also provide additional information and references.

Not Available

1992-08-01T23:59:59.000Z

96

Final Environmental Impact Statement/Environmental Impact Report for continued operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore. Volume 2, Appendices A--D  

SciTech Connect

This Environmental Impact Statement/Environmental Impact Report (EIS/EIR) is prepared pursuant to the National Environmental Policy Act (NEPA) and the California Environmental Quality Act (CEQA). This document analyzes the potential environmental impacts of the proposed action: continued operation, including near-term (within 5 to 10 years) proposed projects, of Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratories, Livermore (SNL, Livermore). Additionally, this document analyzes a no action alternative involving continuing operations at FY 1992 funding levels without further growth, a modification of operations alternative to reduce adverse environmental impacts of operations or facilities, and a shutdown and decommissioning alternative of UC discontinuing its management of LLNL after the current contract expires on September 30, 1992. This document assesses the environmental impacts of the Laboratories` operations on air and water quality, geological and ecological systems, occupational and public health risks, prehistoric and historic resources, endangered species, floodplains and wetlands, socioeconomic resources, hazardous waste management, site contamination, and other environmental issues. The EIS/EIR is divided into five volumes and two companion reports. This volume contains the Final EIS/EIR technical appendices which provide technical support for the analyses in Volume 1 and also provide additional information and references.

Not Available

1992-08-01T23:59:59.000Z

97

High Performance Class-AB Output Stage Operational Amplifiers for Continuous-time Sigma-delta ADC  

E-Print Network (OSTI)

One of the most critical blocks in a wide-band continuous time sigma delta (CTSD) analog-to-digital converter (ADC) is the loop filter. For most loop filter topologies, the performance of the filter depends largely on the performance...

Krishnan, Lakshminarasimhan

2012-10-19T23:59:59.000Z

98

Operation of terahertz quantum-cascade lasers at 164 K in pulsed mode and at 117 K in continuous-wave mode.  

SciTech Connect

We report the demonstration of a terahertz quantum-cascade laser that operates up to 164 K in pulsed mode and 117 K in continuous-wave mode at approximately 3.0 THz. The active region was based on a resonant-phonon depopulation scheme and a metal-metal waveguide was used for modal confinement. Copper to copper thermocompression wafer bonding was used to fabricate the waveguide, which displayed improved thermal properties compared to a previous indium-gold bonding method.

Kumar, Sushil (Massachusetts Institute of Technology, Cambridge, MA); Williams, Benjamin S. (Massachusetts Institute of Technology, Cambridge, MA); Hu, Qing (Massachusetts Institute of Technology, Cambridge, MA); Reno, John Louis

2005-04-01T23:59:59.000Z

99

Thermal analysis of an innovative heat pump operated desalination plant  

SciTech Connect

Sea and brackish water desalination can contribute to solve the problem of fresh water shortage in many and regions of the world. Nowadays most of the installed desalination plants employ distillation processes, like Multistage Flash (MSF), Multi effect Distillation (MED) and Vapor Compression (VC). VC process is called Mechanical Vapor Compression (MVC) when it employs a mechanical compressor, while it is called Thermal Compression when it employs a steam-ejector compressor. In this paper a new distillation plant for the treatment of sea water for drinking water purposes is presented. The most innovative feature of this system is the use of a heat pump as part of the desalting unit. The use of the heat pump in the proposed system enables desalting water evaporation and steam condensation at the same temperature, unlike conventional VC desalting systems where a steam compression stage is necessary. A thermal analysis of the heat pump-operated desalination (HPD) plant and a comparison between the HPD and a conventional MVC plant is presented, in order to determine the main advantages and disadvantages of the new system.

Site, V.D. [National Research Council of Italy, Rome (Italy)

1995-12-31T23:59:59.000Z

100

Draft Site-wide Environmental Impact Statement for Continued Operation of Lawrence Livermore National Laboratory and Supplemental Stockpile Stewardship and Management Programmatic Environmental Impact Statement  

SciTech Connect

This ''Site-wide Environmental Impact Statement for Continued Operation of Lawrence Livermore National Laboratory and Supplemental Stockpile Stewardship and Management Programmatic Environmental Impact Statement'' (LLNL SW/SPEIS) describes the purpose and need for agency action for the continued operation of LLNL and analyzes the environmental impacts of these operations. The primary purpose of continuing operation of LLNL is to provide support for the National Nuclear Security Administration's (NNSA's) nuclear weapons stockpile stewardship missions. LLNL, located about 40 miles east of San Francisco, California, is also needed to support other U.S. Department of Energy (DOE) programs and Federal agencies such as the U.S. Department of Defense, Nuclear Regulatory Commission, U.S. Environmental Protection Agency (EPA), and the newly established U.S. Department of Homeland Security. This LLNL SW/SPEIS analyzes the environmental impacts of reasonable alternatives for ongoing and foreseeable future operations, facilities, and activities at LLNL. The reasonable alternatives include the No Action Alternative, Proposed Action, and the Reduced Operation Alternative. The major decision to be made by DOE/NNSA is to select one of the alternatives for the continued operation of the LLNL. As part of the Proposed Action, DOE/NNSA is considering: using additional materials including plutonium on the National Ignition Facility (NIF); increasing the administrative limit for plutonium in the Superblock, which includes the Plutonium Facility, the Tritium Facility, and the Hardened Engineering Test Building; conducting the Integrated Technology Project, using laser isotope separation to provide material for Stockpile Stewardship experiments, in the Plutonium Facility; increasing the material-at-risk limit for the Plutonium Facility; and increasing the Tritium Facility material-at-risk. A discussion of these issues is presented in Section S.5.2, Proposed Action. The ''National Environmental Policy Act'' (NEPA) establishes environmental policy, sets goals, and provides means for implementing the policy. NEPA contains provisions to ensure that Federal agencies adhere to the letter and spirit of the Act. The key provision requires preparation of an environmental impact statement on ''major Federal actions significantly affecting the quality of the human environment'' (40 ''Code of Federal Regulations'' [CFR] {section}1502.3). NEPA ensures that environmental information is available to public officials and citizens before decisions are made and actions are taken (40 CFR {section}1500.1[b]). DOE has a policy to prepare sitewide environmental impact statements documents for certain large, multiple-facility sites such as LLNL (10 CFR {section}1021.330). In August 1992, DOE released the ''Final Environmental Impact Statement and Environmental Impact Report for Continued Operations of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore'' (LLNL EIS/EIR). A Record of Decision (ROD) (58 ''Federal Register'' [FR] 6268) was issued in January 1993. With the passage of more than 10 years since the publication of the 1992 LLNL EIS/EIR (DOE/EIS-0157) and because of proposed modifications to existing projects and new programs, NNSA determined that it was appropriate to prepare a new LLNL SW/SPEIS.

N /A

2004-02-27T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

The Use of Operational Research and Systems Analysis in Decision Making in Unilever  

Science Journals Connector (OSTI)

...Use of Operational Research and Systems Analysis in Decision Making in Unilever...investment and withdrawal problems. Systems analysis helps us to study the long-term...current information and we have computer based financial models to enable...

1977-01-01T23:59:59.000Z

102

Technical information report: Plasma melter operation, reliability, and maintenance analysis  

SciTech Connect

This document provides a technical report of operability, reliability, and maintenance of a plasma melter for low-level waste vitrification, in support of the Hanford Tank Waste Remediation System (TWRS) Low-Level Waste (LLW) Vitrification Program. A process description is provided that minimizes maintenance and downtime and includes material and energy balances, equipment sizes and arrangement, startup/operation/maintence/shutdown cycle descriptions, and basis for scale-up to a 200 metric ton/day production facility. Operational requirements are provided including utilities, feeds, labor, and maintenance. Equipment reliability estimates and maintenance requirements are provided which includes a list of failure modes, responses, and consequences.

Hendrickson, D.W. [ed.

1995-03-14T23:59:59.000Z

103

NREL: Energy Analysis - Distributed Generation Energy Technology Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Operations and Maintenance Costs Operations and Maintenance Costs Transparent Cost Database Button The following charts indicate recent operations and maintenance (O&M) cost estimates for distributed generation (DG) renewable energy technologies. The charts provide a compilation of available national-level cost data from a variety of sources. Costs in your specific location will vary. The red horizontal lines represent the first standard deviation of the mean. The U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP) sponsored the distributed generation data used within these charts. If you are seeking utility-scale technology operations and maintenance estimates, please visit the Transparent Cost Database website for NREL's information regarding vehicles, biofuels, and electricity generation.

104

Collection and Analysis of Reservoir Data from Testing and Operation...  

Open Energy Info (EERE)

Reservoir Data from Testing and Operation of the Raft River 5 MW Power Plant Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Proceedings: Collection...

105

Environmental Impact Statement and Environmental Impact Report for Continued Operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1-1992/01eis0157_rg.html[6/24/2011 4:00:49 PM] 1-1992/01eis0157_rg.html[6/24/2011 4:00:49 PM] READER'S GUIDE The Final EIS/EIR is organized to assist the reader's understanding of the complex operations at Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore. Organization of Documents The EIS/EIR is divided into five volumes and two companion reports: Volume I. This volume contains the Final EIS/EIR, which in part relies on the detailed information in the appendices, and comprehensively discusses the proposed action, the alternatives, and the existing conditions and impacts of the proposed action and the alternatives. Volume II. This volume contains the Final EIS/EIR technical appendices which provide technical support for the analyses in Volume I and also provide additional information and references. Appendix E was originally identified in

106

Sensitivity Analysis of Optimal Operation of an Activated Sludge Process Model for Economic Controlled Variable Selection  

E-Print Network (OSTI)

Sensitivity Analysis of Optimal Operation of an Activated Sludge Process Model for Economic operation conducted on an activated sludge process model based on the test-bed benchmark simulation model no structure that leads to optimal economic operation, while promptly rejecting disturbances at lower layers

Skogestad, Sigurd

107

DOE/EIS-0380: 2008 Site-Wide Environmental Impact Statement for the Continued Operation of Los Alamos National Laboratory Mitigation Action Plan (December 2008)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Title: Title: 2008 Site-Wide Environmental Impact Statement for the Continued Operation of Los Alamos National Laboratory (DOE/EIS 0380) Mitigation Action Plan U.S. Department of Energy Date: December 2008 Los Alamos National Laboratory, an affirmative action/equal opportunity employer, is operated by the Los Alamos National Security, LLC for the National Nuclear Security Administration of the U.S. Department of Energy under contract DE-AC52-06NA25396. By acceptance of this article, the publisher recognizes that the U.S. Government retains a nonexclusive, royalty-free license to publish or reproduce the published form of this contribution, or to allow others to do so, for U.S. Government purposes. Los Alamos National Laboratory requests that the publisher identify this

108

OPERATIONAL MODAL ANALYSIS AND WAVELET TRANSFORMATION FOR DAMAGE IDENTIFICATION IN WIND TURBINE BLADES  

E-Print Network (OSTI)

OPERATIONAL MODAL ANALYSIS AND WAVELET TRANSFORMATION FOR DAMAGE IDENTIFICATION IN WIND TURBINE-frequency modes. KEYWORDS : Wind Turbine Blades, Debonding, Wavelet Transformation, Operational Modal Analysis. INTRODUCTION While failure can happen in any structural component of the wind turbine, one of the most common

Paris-Sud XI, Université de

109

4.6 MATLAB Laboratory Experiment Purpose: This experiment presents the frequency domain analysis of continuous-time  

E-Print Network (OSTI)

4.6 MATLAB Laboratory Experiment Purpose: This experiment presents the frequency domain analysis of continuous-time linear systems using MATLAB. The impulse, step, sinusoidal, and exponential responses. In addition, MATLAB will be used to perform the partial fraction expansion and to find the inverse Laplace

Gajic, Zoran

110

International Microwave Power Institute 127 ANALYSIS OF OPERATIONAL REGIMES  

E-Print Network (OSTI)

for microwave heating. KEY WORDS: Electric field, dissipated power, micro- wave power, model, permittivity heating systems oper ating at 915 MHz is a standard feature protecting the magnetron from reflections LOAD E. Eves and V. Yakovlev Reflections, electric field and dissipated power of a 915 MHz water load

Yakovlev, Vadim

111

Environmental Impact Statement and Environmental Impact Report for Continued Operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Laborat... Laborat... file:///I|/Data%20Migration%20Task/EIS-0157-FEIS-03-1992/05eis0157_f.html[6/27/2011 9:57:50 AM] APPENDIX F ECOLOGY AND BIOLOGICAL ASSESSMENT This appendix contains two major sections. Section F.1 is a discussion of the ecological characteristics at the LLNL Livermore site, LLNL Site 300, and SNL, Livermore (referred to collectively as the study sites); and presents information and data on the flora and fauna in the upland areas (see Appendix G for a detailed analysis of wetlands at the study sites). This section focuses on the biological features of LLNL Site 300 because this 7000-acre site is largely undeveloped and represents the most biologically diverse area under study. In contrast, the LLNL Livermore site and SNL, Livermore are developed areas that provide only marginal wildlife habitat because of the high degree of human activity and the few

112

Process analysis of margarine and tablespread crystallization operations  

E-Print Network (OSTI)

54 56 59 60 63 96 114 139 vn LIST OF TABLES Table Page 1. Conversion table to equipment settings from statistical coded units, 18 2. Response surface design in coded units for margarine and tablespread crystallization operations. 20 3... such as rheology, fIuid dynamics, and crystallization kinetics, and are not unique to equipment geometry or scale. CHAPTER II LITERATURE REVIEW Review of prior knowledge for this study has concentrated on three primary areas; margarine manufacture, rheology...

Garfield, Gary Charles

2012-06-07T23:59:59.000Z

113

POWER GRID DYNAMICS: ENHANCING POWER SYSTEM OPERATION THROUGH PRONY ANALYSIS  

SciTech Connect

Prony Analysis is a technique used to decompose a signal into a series consisting of weighted complex exponentials and promises to be an effi cient way of recognizing sensitive lines during faults in power systems such as the U.S. Power grid. Positive Sequence Load Flow (PSLF) was used to simulate the performance of a simple two-area-four-generator system and the reaction of the system during a line fault. The Dynamic System Identifi cation (DSI) Toolbox was used to perform Prony analysis and use modal information to identify key transmission lines for power fl ow adjustment to improve system damping. The success of the application of Prony analysis methods to the data obtained from PSLF is reported, and the key transmission line for adjustment is identifi ed. Future work will focus on larger systems and improving the current algorithms to deal with networks such as large portions of the Western Electricity Coordinating Council (WECC) power grid.

Ray, C.; Huang, Z.

2007-01-01T23:59:59.000Z

114

Final Site-wide Environmental Impact Statement for Continued Operation of Lawrence Livermore National Laboratory and Supplemental Stockpile Stewardship and Management Programmatic Environmental Impact Statement  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

I I Chapters 1 through 12 Prepared by: COVER SHEET RESPONSIBLE AGENCY: U.S. Department of Energy (DOE) National Nuclear Security Administration TITLE: Final Site-wide Environmental Impact Statement for Continued Operation of Lawrence Livermore National Laboratory and Supplemental Stockpile Stewardship and Management Programmatic Environmental Impact Statement (DOE/EIS-0348 and DOE/EIS-0236-S3) CONTACT: For further information on this EIS, For general information on the DOE Call: 1-877-388-4930, or contact National Environmental Policy Act (NEPA) process, write or call: Thomas Grim Carol Borgstrom, Director Livermore Site Office Document Manager Office of NEPA Policy and Compliance NNSA (EH-42) 7000 East Avenue U.S. Department of Energy

115

Final Site-wide Environmental Impact Statement for Continued Operation of Lawrence Livermore National Laboratory and Supplemental Stockpile Stewardship and Management Programmatic Environmental Impact Statement  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Summary Summary Prepared by: COVER SHEET RESPONSIBLE AGENCY: U.S. Department of Energy (DOE) National Nuclear Security Administration TITLE: Final Site-wide Environmental Impact Statement for Continued Operation of Lawrence Livermore National Laboratory and Supplemental Stockpile Stewardship and Management Programmatic Environmental Impact Statement (DOE/EIS-0348 and DOE/EIS-0236-S3) CONTACT: For further information on this EIS, For general information on the DOE Call: 1-877-388-4930, or contact National Environmental Policy Act (NEPA) process, write or call: Thomas Grim Carol Borgstrom, Director Livermore Site Office Document Manager Office of NEPA Policy and Compliance NNSA (EH-42) 7000 East Avenue U.S. Department of Energy MS L-293 1000 Independence Avenue, SW

116

Final Site-wide Environmental Impact Statement for Continued Operation of Lawrence Livermore National Laboratory and Supplemental Stockpile Stewardship and Management Programmatic Environmental Impact Statement  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

III III Appendix E through P Prepared by: COVER SHEET RESPONSIBLE AGENCY: U.S. Department of Energy (DOE) National Nuclear Security Administration TITLE: Final Site-wide Environmental Impact Statement for Continued Operation of Lawrence Livermore National Laboratory and Supplemental Stockpile Stewardship and Management Programmatic Environmental Impact Statement (DOE/EIS-0348 and DOE/EIS-0236-S3) CONTACT: For further information on this EIS, For general information on the DOE Call: 1-877-388-4930, or contact National Environmental Policy Act (NEPA) process, write or call: Thomas Grim Carol Borgstrom, Director Livermore Site Office Document Manager Office of NEPA Policy and Compliance NNSA (EH-42) 7000 East Avenue U.S. Department of Energy

117

Final Site-wide Environmental Impact Statement for Continued Operation of Lawrence Livermore National Laboratory and Supplemental Stockpile Stewardship and Management Programmatic Environmental Impact Statement  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

II II Appendix A through D Prepared by: COVER SHEET RESPONSIBLE AGENCY: U.S. Department of Energy (DOE) National Nuclear Security Administration TITLE: Final Site-wide Environmental Impact Statement for Continued Operation of Lawrence Livermore National Laboratory and Supplemental Stockpile Stewardship and Management Programmatic Environmental Impact Statement (DOE/EIS-0348 and DOE/EIS-0236-S3) CONTACT: For further information on this EIS, For general information on the DOE Call: 1-877-388-4930, or contact National Environmental Policy Act (NEPA) process, write or call: Thomas Grim Carol Borgstrom, Director Livermore Site Office Document Manager Office of NEPA Policy and Compliance NNSA (EH-42) 7000 East Avenue U.S. Department of Energy

118

2013 Annual Workforce Analysis and Staffing Plan Report- Savannah River Operations Office  

Energy.gov (U.S. Department of Energy (DOE))

Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities.

119

2012 Annual Workforce Analysis and Staffing Plan Report- Richland Operations Office  

Energy.gov (U.S. Department of Energy (DOE))

Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities.

120

2012 Annual Workforce Analysis and Staffing Plan Report- Idaho Operations Office  

Energy.gov (U.S. Department of Energy (DOE))

Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities.

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

2011 Annual Workforce Analysis and Staffing Plan Report- Savannah River Operations Office  

Energy.gov (U.S. Department of Energy (DOE))

Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities.

122

2011 Annual Workforce Analysis and Staffing Plan Report- Richland Operations Office  

Energy.gov (U.S. Department of Energy (DOE))

Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities.

123

2011 Annual Workforce Analysis and Staffing Plan Report- Idaho Operations Office  

Energy.gov (U.S. Department of Energy (DOE))

Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities.

124

2013 Annual Workforce Analysis and Staffing Plan Report- Idaho Operations Office  

Energy.gov (U.S. Department of Energy (DOE))

Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities.

125

2014 Annual Workforce Analysis and Staffing Plan Report- Idaho Operations Office  

Energy.gov (U.S. Department of Energy (DOE))

Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities.

126

2012 Annual Workforce Analysis and Staffing Plan Report- Savannah River Operations Office  

Energy.gov (U.S. Department of Energy (DOE))

Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities.

127

2013 Annual Workforce Analysis and Staffing Plan Report- Richland Operations Office  

Energy.gov (U.S. Department of Energy (DOE))

Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities.

128

2014 Annual Workforce Analysis and Staffing Plan Report- Richland Operations Office  

Energy.gov (U.S. Department of Energy (DOE))

Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities.

129

2014 Annual Workforce Analysis and Staffing Plan Report- Savannah River Operations Office  

Energy.gov (U.S. Department of Energy (DOE))

Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities.

130

2010 Annual Workforce Analysis and Staffing Plan Report- Savannah River Operations Office  

Energy.gov (U.S. Department of Energy (DOE))

Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities.

131

Preliminary analysis of fission gas behavior and fuel response during an LMFBR operational transient  

SciTech Connect

This summary presents results obtained from a preliminary analysis of gas behavior and oxide fuel response during an LMFBR operational transient. The DiMelfi and Deitrich model is extrapolated to operational transient regimes to delineate brittle versus ductile fuel response modes. All pertinent parameters necessary for application of the DiMelfi and Deitrich model were obtained from the LIFE-3 code.

Liu, Y.Y.

1983-01-01T23:59:59.000Z

132

Receiver Operating Characteristic Analysis for Detecting Explosives-related Threats  

SciTech Connect

The Department of Homeland Security (DHS) and the Transportation Security Administration (TSA) are interested in developing a standardized testing procedure for determining the performance of candidate detection systems. This document outlines a potential method for judging detection system performance as well as determining if combining the information from a legacy system with a new system can signi��������cantly improve performance. In this document, performance corresponds to the Neyman-Pearson criterion applied to the Receiver Operating Characteristic (ROC) curves of the detection systems in question. A simulation was developed to investigate how the amount of data provided by the vendor in the form of the ROC curve e�������¤ects the performance of the combined detection system. Furthermore, the simulation also takes into account the potential e�������¤ects of correlation and how this information can also impact the performance of the combined system.

Mark E. Oxley; Alexander M. Venzin

2012-11-14T23:59:59.000Z

133

Analysis of continuously rotating quadrupole focusing channels using generalized Courant-Snyder theory  

SciTech Connect

By extending the recently developed generalized Courant-Snyder theory for coupled transverse beam dynamics, we have constructed the Gaussian beam distribution and its projections with arbitrary mode emittance ratios. The new formulation has been applied to a continuously rotating quadrupole focusing channel because the basic properties of this channel are known theoretically and could also be investigated experimentally in a compact setup such as the linear Paul trap configuration. The new formulation retains a remarkably similar mathematical structure to the original Courant-Snyder theory, and thus, provides a powerful theoretical tool to investigate coupled transverse beam dynamics in general and more complex linear focusing channels.

Chung, Moses [Accelerator Physics Center, Fermi National Accelerator Laboratory, Batavia, Illinois 60510 (United States)] [Accelerator Physics Center, Fermi National Accelerator Laboratory, Batavia, Illinois 60510 (United States); Qin, Hong [Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543 (United States) [Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543 (United States); Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Gilson, Erik P.; Davidson, Ronald C. [Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543 (United States)] [Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543 (United States)

2013-08-15T23:59:59.000Z

134

Data Collection for Class-8 Long-Haul Operations and Fuel Economy Analysis  

NLE Websites -- All DOE Office Websites (Extended Search)

Long-Haul Long-Haul Operations and Fuel Economy Analysis A s part of a long-term study sponsored by the U.S. Department of Energy (DOE) Office of Vehicle Technologies (OVT), the Oak Ridge National Laboratory (ORNL) in conjunction with a number of industry partners (Michelin Americas Research Company - Michelin), have collected data and information related to Class-8 heavy truck long-haul operations in real-world

135

Geographic and Operational Site Parameters List (GOSPL) for the 2004 Composite Analysis  

SciTech Connect

This report briefly describes each of the key data fields, including the source(s) of data, and provides the resulting inputs to be used for the 2004 Composite Analysis. A master spreadsheet termed the Geographic and Operational Site Parameters List (GOSPL) was assembled to facilitate the generation of keyword input files containing general information on each waste site, its operational/disposal history, and its environmental settings (past, current, and future).

Last, George V.; Nichols, William E.; Kincaid, Charles T.

2004-07-01T23:59:59.000Z

136

Collection and Analysis of Reservoir Data from Testing and Operation of the  

Open Energy Info (EERE)

Collection and Analysis of Reservoir Data from Testing and Operation of the Collection and Analysis of Reservoir Data from Testing and Operation of the Raft River 5 MW Power Plant Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Conference Proceedings: Collection and Analysis of Reservoir Data from Testing and Operation of the Raft River 5 MW Power Plant Details Activities (1) Areas (1) Regions (0) Abstract: The Raft River 5 MW power plant will be on-line some time this spring. During testing of the supply and injection system prior to plant start-up and during testing of the plant itself, data can be collected and used to calibrate computer models, refine predicted drawdowns and interference effects, monitor changing temperatures, and recalculate reservoir parameters. Analytic methods have been used during reservoir testing at Raft River to calculate reservoir coefficients. However,

137

Continuous time random walk analysis of solute transport in fractured porous media  

SciTech Connect

The objective of this work is to discuss solute transport phenomena in fractured porous media, where the macroscopic transport of contaminants in the highly permeable interconnected fractures can be strongly affected by solute exchange with the porous rock matrix. We are interested in a wide range of rock types, with matrix hydraulic conductivities varying from almost impermeable (e.g., granites) to somewhat permeable (e.g., porous sandstones). In the first case, molecular diffusion is the only transport process causing the transfer of contaminants between the fractures and the matrix blocks. In the second case, additional solute transfer occurs as a result of a combination of advective and dispersive transport mechanisms, with considerable impact on the macroscopic transport behavior. We start our study by conducting numerical tracer experiments employing a discrete (microscopic) representation of fractures and matrix. Using the discrete simulations as a surrogate for the 'correct' transport behavior, we then evaluate the accuracy of macroscopic (continuum) approaches in comparison with the discrete results. However, instead of using dual-continuum models, which are quite often used to account for this type of heterogeneity, we develop a macroscopic model based on the Continuous Time Random Walk (CTRW) framework, which characterizes the interaction between the fractured and porous rock domains by using a probability distribution function of residence times. A parametric study of how CTRW parameters evolve is presented, describing transport as a function of the hydraulic conductivity ratio between fractured and porous domains.

Cortis, Andrea; Cortis, Andrea; Birkholzer, Jens

2008-06-01T23:59:59.000Z

138

ANALYSIS OF EMERGING NDE TECHNIQUES: METHODS FOR EVALUATING AND IMPLEMENTING CONTINUOUS ONLINE MONITORING  

SciTech Connect

One of the goals of the program for the proactive management of materials degradation (PMMD) is to manage proactively the in-service degradation of metallic components in aging NPPs. As some forms of degradation, such as stress corrosion cracking, are characterized by a long initiation time followed by a rapid growth phase, new inspection or monitoring technologies may be required. New nondestructive evaluation (NDE) techniques that may be needed include techniques to find stress corrosion cracking (SCC) precursors, on-line monitoring techniques to detect cracks as they initiate and grow, as well as advances in NDE technologies. This paper reports on the first part of the development of a methodology to determine the effectiveness of these emerging NDE techniques for managing metallic degradation. This methodology will draw from experience derived from evaluating techniques that have "emerged" in the past. The methodology will follow five stages: a definition of inspection parameters, a technical evaluation, laboratory testing, round robin testing, and the design of a performance demonstration program. This methodology will formalize the path taken for previous techniques and set a predictable course for future NDE techniques. This paper then applies the expert review section of the methodology to the acoustic emission technique to evaluate the use of acoustic emission in performing continuous online monitoring of reactor components.

Cumblidge, Stephen E.; Doctor, Steven R.; Bond, Leonard J.; Taylor, Theodore T.; Lupold, Timothy R.; Hull, Amy; Malik, Shah

2009-08-05T23:59:59.000Z

139

Process hazards analysis (PrHA) program, bridging accident analyses and operational safety  

SciTech Connect

Recently the Final Safety Analysis Report (FSAR) for the Plutonium Facility at Los Alamos National Laboratory, Technical Area 55 (TA-55) was revised and submitted to the US. Department of Energy (DOE). As a part of this effort, over seventy Process Hazards Analyses (PrHAs) were written and/or revised over the six years prior to the FSAR revision. TA-55 is a research, development, and production nuclear facility that primarily supports US. defense and space programs. Nuclear fuels and material research; material recovery, refining and analyses; and the casting, machining and fabrication of plutonium components are some of the activities conducted at TA-35. These operations involve a wide variety of industrial, chemical and nuclear hazards. Operational personnel along with safety analysts work as a team to prepare the PrHA. PrHAs describe the process; identi fy the hazards; and analyze hazards including determining hazard scenarios, their likelihood, and consequences. In addition, the interaction of the process to facility systems, structures and operational specific protective features are part of the PrHA. This information is rolled-up to determine bounding accidents and mitigating systems and structures. Further detailed accident analysis is performed for the bounding accidents and included in the FSAR. The FSAR is part of the Documented Safety Analysis (DSA) that defines the safety envelope for all facility operations in order to protect the worker, the public, and the environment. The DSA is in compliance with the US. Code of Federal Regulations, 10 CFR 830, Nuclear Safety Management and is approved by DOE. The DSA sets forth the bounding conditions necessary for the safe operation for the facility and is essentially a 'license to operate.' Safely of day-to-day operations is based on Hazard Control Plans (HCPs). Hazards are initially identified in the PrI-IA for the specific operation and act as input to the HCP. Specific protective features important to worker safety are incorporated so the worker can readily identify the safety parameters of the their work. System safety tools such as Preliminary Hazard Analysis, What-If Analysis, Hazard and Operability Analysis as well as other techniques as necessary provide the groundwork for both determining bounding conditions for facility safety, operational safety, and day-to-clay worker safety.

Richardson, J. A. (Jeanne A.); McKernan, S. A. (Stuart A.); Vigil, M. J. (Michael J.)

2003-01-01T23:59:59.000Z

140

Analysis of Variable Speed Optimization Operation Effect of Different?type Pumps in Jiangdu Pumping Station  

Science Journals Connector (OSTI)

The following paper puts forward 45 combination schemes of different?type pumps in different daily?average heads and operation loads in Jiangdu Pumping Station. Based on every scheme the minimum electricity consumption cost selected as the objective function this paper gives the results of variable speed optimal operations with dynamic planning methods in both considering time?sharing electricity prices and not simultaneously it gives the results of fixed speed conventional operation considering time?sharing electricity prices. Then according to the unit energy consumption cost the paper gives comparison analysis of the effect of different?type pumps in variable speed optimization operation the conclusions can offer decision?making bases for optimization research of pumping stations considering time?sharing electricity prices and tide levels of Yangtze River and offer references for transformation and economical operation of large and medium?size pumping stations.

Qiu Jinxian; Cheng Jilin; Luo Jinyao; Zhang Rentian; Zhang Lihua; Gong Yi

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

2011 Annual Workforce Analysis and Staffing Plan Report - Idaho Operations Office  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

January 19~ 2012 Subject: Annual Workforce Analysis and Staffing Plan Report for Calendar Year 2011 (OS-DM-12-004) To: Karen L. Boardman, Chairperson Federal Technical Capability Panel National Nuclear Security Administration Reference: Memorandum, Karen Boardman to Distribution, "Annual Workforce Analysis and Staffing Plan Report for Calendar Year 2011," dated October 13,2011 In accordance with direction in the reference, the Department of Energy, Idaho Operations Office (DOE-ID) performed a workforce analysis and developed an Annual Workforce Analysis and Staffing Report. The Report is hereby submitted for the Federal Technical Capability Program (FTCP) review and incorporation into the FTCP Annual Report to the Secretary.

142

Ex post power economic analysis of record of decision operational restrictions at Glen Canyon Dam.  

SciTech Connect

On October 9, 1996, Bruce Babbitt, then-Secretary of the U.S. Department of the Interior signed the Record of Decision (ROD) on operating criteria for the Glen Canyon Dam (GCD). Criteria selected were based on the Modified Low Fluctuating Flow (MLFF) Alternative as described in the Operation of Glen Canyon Dam, Colorado River Storage Project, Arizona, Final Environmental Impact Statement (EIS) (Reclamation 1995). These restrictions reduced the operating flexibility of the hydroelectric power plant and therefore its economic value. The EIS provided impact information to support the ROD, including an analysis of operating criteria alternatives on power system economics. This ex post study reevaluates ROD power economic impacts and compares these results to the economic analysis performed prior (ex ante) to the ROD for the MLFF Alternative. On the basis of the methodology used in the ex ante analysis, anticipated annual economic impacts of the ROD were estimated to range from approximately $15.1 million to $44.2 million in terms of 1991 dollars ($1991). This ex post analysis incorporates historical events that took place between 1997 and 2005, including the evolution of power markets in the Western Electricity Coordinating Council as reflected in market prices for capacity and energy. Prompted by ROD operational restrictions, this analysis also incorporates a decision made by the Western Area Power Administration to modify commitments that it made to its customers. Simulated operations of GCD were based on the premise that hourly production patterns would maximize the economic value of the hydropower resource. On the basis of this assumption, it was estimated that economic impacts were on average $26.3 million in $1991, or $39 million in $2009.

Veselka, T. D.; Poch, L. A.; Palmer, C. S.; Loftin, S.; Osiek, B; Decision and Information Sciences; Western Area Power Administration

2010-07-31T23:59:59.000Z

143

Technoeconomic Analysis of Biofuel Production and Biorefinery Operation Utilizing Geothermal Energy  

Science Journals Connector (OSTI)

Technoeconomic Analysis of Biofuel Production and Biorefinery Operation Utilizing Geothermal Energy ... A technoeconomic study is conducted to assess the feasibility of integrating geothermal energy into a biorefinery for biofuel production. ... Geothermal energy is utilized in the refinery to generate process steam for gasification and steam-methane reforming in addition to providing excess electricity via the organic Rankine cycle. ...

Sudhanya Banerjee; Jordan A. Tiarks; Maciej Lukawski; Song-Charng Kong; Robert C. Brown

2013-02-28T23:59:59.000Z

144

Periodic orbit analysis of a system with continuous symmetry - a tutorial  

E-Print Network (OSTI)

Dynamical systems with translational or rotational symmetry arise frequently in studies of spatially extended physical systems, such as Navier-Stokes flows on periodic domains. In these cases, it is natural to express a state of the fluid in terms of a Fourier series truncated to a finite number of modes. Here we study a 4-dimensional two-mode SO(2)-equivariant model of this type, the smallest possible truncation that retains the symmetry while remaining high-dimensional enough to allow for chaotic dynamics. A crucial step in analysis of such a system is symmetry reduction. We use the model to illustrate different symmetry-reduction schemes. Its relative equilibria are conveniently determined by rewriting the dynamics in terms of a symmetry-invariant polynomial basis. However, for study of chaotic dynamics, the `method of slices', applicable also to very high-dimensional problems, is preferable. We show that a Poincar\\'e section within the `slice' can be used to further reduce this flow to what is for all practical purposes a unimodal map. This enables us to systematically determine all relative periodic orbits and their symbolic dynamics up to any desired period. We then compute several dynamical averages using relative periodic orbits and discuss the convergence of such computations.

Nazmi Burak Budanur; Daniel Borrero-Echeverry; Predrag Cvitanovi?

2014-11-12T23:59:59.000Z

145

EIS-0026-SA-07: Supplement Analysis | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7: Supplement Analysis EIS-0026-SA-07: Supplement Analysis Waste Isolation Pilot Plant Site-Wide Operations, Carlsbad Field Office The Proposed Action is to continue the...

146

Sampling and analysis plan for the site characterization of the waste area Grouping 1 groundwater operable unit at Oak Ridge National Laboratory  

SciTech Connect

Waste Area Grouping (WAG) 1 at Oak Ridge National Laboratory (ORNL) includes all of the former ORNL radioisotope research, production, and maintenance facilities; former waste management areas; and some former administrative buildings. Site operations have contaminated groundwater, principally with radiological contamination. An extensive network of underground pipelines and utilities have contributed to the dispersal of contaminants to a known extent. In addition, karst geology, numerous spills, and pipeline leaks, together with the long and varied history of activities at specific facilities at ORNL, complicate contaminant migration-pathway analysis and source identification. To evaluate the extent of contamination, site characterization activity will include semiannual and annual groundwater sampling, as well as monthly water level measurements (both manual and continuous) at WAG 1. This sampling and analysis plan provides the methods and procedures to conduct site characterization for the Phase 1 Remedial Investigation of the WAG 1 Groundwater Operable Unit.

NONE

1994-11-01T23:59:59.000Z

147

Analysis of photovoltaic module energy output under operating conditions in South Africa  

SciTech Connect

South Africa does not have any industry standard methodology to evaluate photovoltaic (PV) modules for energy production. The aim of this study is to characterize the energy production of PV modules deployed outdoors at the University of Port Elizabeth (UPE), Summerstrand, South Africa with the view of facilitating such a standard. The system developed for this study was designed to monitor the energy production of seven PV modules under normal operating conditions. An analysis of energy production of three of the PV modules under test, while operating under prevailing outdoor conditions, is given. Measured energy output is also compared with that predicted using an energy model.

Dyk, E.E. van; Meyer, E.L.; Scott, B.J.; O`Connor, D.A.; Wessels, J.B. [Univ. of Port Elizabeth (South Africa). Dept. of Physics

1997-12-31T23:59:59.000Z

148

Introduction to continuous emission monitoring programs. Final report  

SciTech Connect

This document provides a general introduction to continuous emission monitoring for those persons not previously involved in this field. Information is presented on continuous opacity monitoring, as well as instrumental and alternative monitoring techniques for SO2 and NOx (i.e., continuous wet-chemical measurement methods and fuel sampling and analysis methods). This document presents an outline and review of the fundamental concepts, terminology, and procedures used in a continuous emission monitoring program. Also presented are selected technical details necessary to understand the operation of emission monitors, the use of continuous emission monitoring data by air pollution control agencies, and references to other available documents which provide additional information.

Peeler, J.W.

1983-01-01T23:59:59.000Z

149

Office of Analysis and Evaluation of Operational Data 1989 annual report, Power reactors  

SciTech Connect

The annual report of the US Nuclear Regulatory Commission's Office for Analysis and Evaluation of Operational Data (AEOD) is devoted to the activities performed during 1989. The report is published in two separate parts. This document, NUREG-1272, Vol. 4, No. 1, covers power reactors and presents an overview of the operating experience of the nuclear power industry from the NRC perspective, including comments about the trends of some key performance measures. The report also includes the principal findings and issues identified in AEOD studies over the past year and summarizes information from such sources as licensee event reports, diagnostic evaluations, and reports to the NRC's Operations Center. This report also compiles the status of staff actions resulting from previous Incident Investigation Team (IIT) reports. 16 figs., 9 tabs.

None

1990-07-01T23:59:59.000Z

150

2012 Annual Workforce Analysis and Staffing Plan Report - Idaho Operations Office  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4, 2013 4, 2013 Subject: Annual Workforce Analysis and Staffing Plan Report for Calendar Year 2012 (EM-NSPD-13-003) To: Karen L. Boardman, Chairman Federal Technical Capability Panel National Nuclear Security Administration Reference: Memorandum, Karen Boardman to Distribution, "Annual Workforce Analysis and Staffing Plan Report for Calendar Year 2012," dated October 24, 2012 In accordance with direction in the reference, the Department of Energy, Idaho Operations Office (DOE-ID) performed a workforce analysis and developed an Annual Workforce Analysis and Staffing Report. The Report is herby submitted for the Federal Technical Capability Program (FTCP) review and incorporation into the FTCP Annual Report to the Secretary. Questions may be addressed to the DOE-ID FTCP Agent, Mark C. Brown at (208) 526-

151

Report to the US Nuclear Regulatory Commission on Analysis and Evaluation of Operational Data, 1986  

SciTech Connect

This annual report of the US Nuclear Regulatory Commission's Office for Analysis and Evaluation of Operational Data (AEOD) is devoted to the activities performed during calendar year 1986. Comments and observations are provided on operating experience at nuclear power plants and other NRC licensees, including results from selected AEOD studies; summaries of abnormal occurrences involving US nuclear plants; reviews of licensee event reports and their quality, reactor scram experience from 1984 to 1986, engineered safety features actuations, and the trends and patterns analysis program; and assessments of nonreactor and medical misadministration events. In addition, the report provides the year-end status of all recommendations included in AEOD studies, and listings of all AEOD reports issued from 1980 through 1986.

none,

1987-05-01T23:59:59.000Z

152

Analysis of Operation TEAPOT nuclear test BEE radiological and meteorological data  

SciTech Connect

This report describes the Weather Service Nuclear Support Office (WSNSO) analyses of the radiological and meteorological data collected for the BEE nuclear test of Operation TEAPOT. Inconsistencies in the radiological data and their resolution are discussed. The methods of normalizing the radiological data to a standard time and estimating fallout-arrival times are presented. The meteorological situations on event day and the following day are described. A comparison of the WSNSO fallout analysis with an analysis performed in the 1950's is presented. The radiological data used to derive the WSNSO fallout pattern are tabulated in an appendix.

Quinn, V.E.

1986-08-01T23:59:59.000Z

153

Analysis of operation TEAPOT nuclear test ZUCCHINI radiological and meterological data  

SciTech Connect

This report describes the Weather Service Nuclear Support Office (WSNSO) analyses of the radiological and meteorological data collected for the ZUCCHINI nuclear test of Operation TEAPOT. Inconsistencies in the radiological data and their resolution are discussed. The methods of normalizing the radiological data to a standard time and estimating fallout-arrival times are presented. The meteorological situations on event day and the following day are described. A comparison of the WSNSO fallout analysis with an analysis performed in the 1950's is presented. The radiological data used to derive the WSNSO 1986 fallout pattern are tabulated in an appendix.

Quinn, V.E.

1987-03-01T23:59:59.000Z

154

Numerical analysis of docking operation between service vessels and offshore wind turbines  

Science Journals Connector (OSTI)

Abstract Offshore renewable wind energy market is expected to expand dramatically in the next 5–10 years. Reduction of downtime is crucial to the competitiveness of this new sector. One important part of the research efforts is the evaluation of operational limits (weather limits) of different vessel/access concepts for transportation of maintenance personnel, equipment, and spare parts to the offshore wind turbines. This paper gives a brief description of possible types of service vessel and access system. It presents methodologies for numerical analysis of docking operation by an active motion compensated access device and a simple fender. The proposed frequency–domain approach to the analysis of docking operation with fender is new and highly efficient compared to time–domain simulation. The methods have been applied to two vessel/access concepts in this paper and they can be used in docking operability assessments for a variety of vessels that employ an active motion compensated device or a fender as access system to offshore wind turbines.

MingKang Wu

2014-01-01T23:59:59.000Z

155

Continual Learning  

Energy.gov (U.S. Department of Energy (DOE))

Continual Learning is a change initiative which is used to help develop and grow a learning culture within DOE.

156

Operational analysis of an innovative wind powered reverse osmosis system installed in the Canary Islands  

Science Journals Connector (OSTI)

This paper presents an operational analysis of the prototype of an innovative fully autonomous wind powered desalination system. The system consists of a wind farm, made up of two wind turbines and a flywheel, which operates in isolation from the conventional power grids and which supplies the energy needs of a group of eight reverse osmosis (RO) modules throughout the complete desalination process (from the pumping of sea water to the storage of the product water), as well as the energy requirements of the control subsystems. The analysis of the electrical and hydraulic results obtained from this prototype, installed on the island of Gran Canaria in the Canarian Archipelago, shows the technical feasibility of the system design and the automatic operational strategy programmed for it. Amongst other tasks, the automatic operational strategy controls the number of RO plants that have to be connected or disconnected at any given moment in order to match the variable wind energy supply. The results obtained thus far have not revealed any significant variation in the level of quality or average volume of the product water, nor any physical deterioration to the main components of the system as a result of the start-ups and shut-downs required as a result of the variations in the wind energy supply or oscillations of the electrical parameters of voltage and frequency. In conclusion, the system under analysis can be applied to sea water desalination, both on a small and large scale, in coastal regions with a scarcity of water for domestic and/or agricultural use but with wind energy resources.

J.A. Carta; J. González; V. Subiela

2003-01-01T23:59:59.000Z

157

Process systems engineering of continuous pharmaceutical manufacturing  

E-Print Network (OSTI)

Continuous manufacturing offers a number of operational and financial benefits to pharmaceutical companies. This research examines the critical blending step for continuous pharmaceutical manufacturing and the characteristics ...

Abel, Matthew J

2010-01-01T23:59:59.000Z

158

Flexibility and operability analysis of a HEN-integrated natural gas expander plant  

Science Journals Connector (OSTI)

In the heat-exchanger network (HEN) literature, synthesis, design, and flexibility analyses of \\{HENs\\} are done independently from processes to which \\{HENs\\} are integrated. Such analyses are made mostly based on nominal operating conditions at which the HEN's source- and target-stream properties are evaluated. However, terminal-stream properties of \\{HENs\\} depend upon temperatures, pressures, and compositions of the process connected to the HEN. In this work, flexibility and operability issues of a HEN are investigated with rigorous simulations using the process flowsheet simulator HYSYS for a HEN-integrated natural gas turbo-expander plant (TEP) operating under ethane-recovery mode. The contribution of this work is threefold. First, the HEN-plant interactions are exemplified via the process flowsheet simulator. Second, flexibility and operability issues are tackled using the optimization capability of the flowsheet simulator. Third, for highly energy-integrated complex plants like the TEP, the difficulties or impossibilities of automated HEN synthesis and flexibility analysis with process flowsheet simulators are demonstrated.

Alp Er S. Konukman; Ugur Akman

2005-01-01T23:59:59.000Z

159

Analysis of the Impact of Balancing Area Cooperation on the Operation of WECC and the Compounding Effect of Wind and Solar Generation  

SciTech Connect

It is the intent of this analysis to examine the operational benefits of increased cooperation between a large number of WECC operating regions.

Jordan, G.; Piwko, D.

2013-02-01T23:59:59.000Z

160

Analysis of nonlinear dynamics of a cantilever beam-rigid-body MEMS gyroscope using a continuation method  

E-Print Network (OSTI)

The nonlinear dynamics of a microbeam-rigid body gyroscope are investigated by using a continuation method. To study the nonlinear dynamics of the system, the Lagrangian of the system is discretized and the reduced-order model is obtained. By using the continuation method, the frequency-response curves are computed and the stability of response is determined.

Lajimi, Seyed Amir Mousavi

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

An operational analysis of protected-permitted lead-lag left-turn phasing  

E-Print Network (OSTI)

Chair of Advisory Committee: Dr. Daniel B. Fambro This thesis documents an operational analysis of a special type of protected- permitted lead-lag left-turn phasing sequence developed and used by traffic engineers in Dallas, Texas. This phasing, known... as the Dallas phasing, does not follow existing standards for left-turn phasing set forth in the Manual for Uniform Trajfic Control Devices (MUTCD). The objective of this research was to determine whether existing left-turn models can be used to analyze...

Gaston, Gilmer D

2012-06-07T23:59:59.000Z

162

Supplement Analysis for the System Operation Review EIS (DOE/EIS-0170/SA-1)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

20, 2002 20, 2002 REPLY TO ATTN OF: KEC-4 SUBJECT: Supplement Analysis for the System Operation Review EIS (DOE/EIS-0170/SA-1) Anthony G. White - PGPL-5 Public Utility Specialist and Secretary, United States Entity Proposed Action: Non-Treaty Storage Agreement (NTSA) - Contract Extension, Contract Number DE-MS79- 90BP92754. Proposed By: Bonneville Power Administration (BPA) and B.C. Hydro and Power Authority (BC Hydro). Location: British Columbia, Canada. Description of the Proposed Action: BPA and BC Hydro propose to extend the existing NTSA for a period of one year. Analysis: On July 5, 1990, BPA and BC Hydro signed the NTSA, which expanded the amount of non- Treaty storage space available in Canada and extended the then-existing agreement from 1993 to

163

High-Performance Computing for Real-Time Grid Analysis and Operation  

SciTech Connect

Power grids worldwide are undergoing an unprecedented transition as a result of grid evolution meeting information revolution. The grid evolution is largely driven by the desire for green energy. Emerging grid technologies such as renewable generation, smart loads, plug-in hybrid vehicles, and distributed generation provide opportunities to generate energy from green sources and to manage energy use for better system efficiency. With utility companies actively deploying these technologies, a high level of penetration of these new technologies is expected in the next 5-10 years, bringing in a level of intermittency, uncertainties, and complexity that the grid did not see nor design for. On the other hand, the information infrastructure in the power grid is being revolutionized with large-scale deployment of sensors and meters in both the transmission and distribution networks. The future grid will have two-way flows of both electrons and information. The challenge is how to take advantage of the information revolution: pull the large amount of data in, process it in real time, and put information out to manage grid evolution. Without addressing this challenge, the opportunities in grid evolution will remain unfulfilled. This transition poses grand challenges in grid modeling, simulation, and information presentation. The computational complexity of underlying power grid modeling and simulation will significantly increase in the next decade due to an increased model size and a decreased time window allowed to compute model solutions. High-performance computing is essential to enable this transition. The essential technical barrier is to vastly increase the computational speed so operation response time can be reduced from minutes to seconds and sub-seconds. The speed at which key functions such as state estimation and contingency analysis are conducted (typically every 3-5 minutes) needs to be dramatically increased so that the analysis of contingencies is both comprehensive and real time. An even bigger challenge is how to incorporate dynamic information into real-time grid operation. Today’s online grid operation is based on a static grid model and can only provide a static snapshot of current system operation status, while dynamic analysis is conducted offline because of low computational efficiency. The offline analysis uses a worst-case scenario to determine transmission limits, resulting in under-utilization of grid assets. This conservative approach does not necessarily lead to reliability. Many times, actual power grid scenarios are not studied, and they will push the grid over the edge and resulting in outages and blackouts. This chapter addresses the HPC needs in power grid analysis and operations. Example applications such as state estimation and contingency analysis are given to demonstrate the value of HPC in power grid applications. Future research directions are suggested for high performance computing applications in power grids to improve the transparency, efficiency, and reliability of power grids.

Huang, Zhenyu; Chen, Yousu; Chavarría-Miranda, Daniel

2013-10-31T23:59:59.000Z

164

Office for Analysis and Evaluation of Operational Data 1996 annual report. Volume 10, Number 1: Reactors  

SciTech Connect

This annual report of the US Nuclear Regulatory Commission`s Office for Analysis and Evaluation of Operational Data (AEOD) describes activities conducted during 1996. The report is published in three parts. NUREG-1272, Vol. 10, No. 1, covers power reactors and presents an overview of the operating experience of the nuclear power industry from the NRC perspective, including comments about trends of some key performance measures. The report also includes the principal findings and issues identified in AEOD studies over the past year and summarizes information from such sources as licensee event reports and reports to the NRC`s Operations Center. NUREG-1272, Vol. 10, No. 2, covers nuclear materials and presents a review of the events and concerns during 1996 associated with the use of licensed material in nonreactor applications, such as personnel overexposures and medical misadministrations. Both reports also contain a discussion of the Incident Investigation Team program and summarize both the Incident Investigation Team and Augmented Inspection Team reports. Each volume contains a list of the AEOD reports issued from CY 1980 through 1996. NUREG-1272, Vol. 10, No. 3, covers technical training and presents the activities of the Technical Training Center in support of the NRC`s mission in 1996.

NONE

1997-12-01T23:59:59.000Z

165

Office for Analysis and Evaluation of Operational Data 1990 annual report  

SciTech Connect

The annual report of the US Nuclear Regulatory Commission's Office for Analysis and Evaluation of Operational Data (AEOD) is devoted to the activities performed during 1990. The report is published in two separate parts. This document NUREG-1272, Vol. 5, No. 1, covers power reactors and presents an overview of the operating experience of the nuclear power industry from the NRC perspective, including comments about the trends of some key performance measures. The report also includes the principal findings and issues identified in AEOD studies over the past year and summarizes information from such sources as licensee event reports, diagnostic evaluations, and reports to the NRC's Operations Center. NUREG-1272, Vol.5, No. 2, covers nonreactors and presents a review of the events and concerns during 1990 associated with the use of licensed material in nonreactor applications, such as personnel overexposures and medical misadministrations. The reports contain a discussion of the Incident Investigation Team program and summarize the Incident Investigation Team and Augmented Inspection Team reports for that group of licensees. Each volume contains a list of the AEOD reports issued for 1980 through 1990. 9 figs., 8 tabs.

None

1991-07-01T23:59:59.000Z

166

Running time variability and resource allocation : a data-driven analysis of high-frequency bus operations  

E-Print Network (OSTI)

Running time variability is one of the most important factors determining service quality and operating cost of high-frequency bus transit. This research aims to improve performance analysis tools currently used in the bus ...

Sánchez-Martínez, Gabriel Eduardo

2013-01-01T23:59:59.000Z

167

Final Site-Wide Environmental Impact Statement for the Continued Operation of the Los Alamos National Laboratory, Los Alamos, New Mexico (05/2008)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

I I MAJOR MATERIAL DISPOSAL AREA REMEDIATION, CANYON CLEANUPS, AND OTHER CONSENT ORDER ACTIONS I-1 Implementing the Consent Order NNSA intends to implement actions necessary to comply with the Compliance Order on Consent (Consent Order) regardless of decisions it makes on other actions analyzed in the LANL SWEIS. Actions associated with implementing the Consent Order are included in the Expanded Operations Alternative; however, their implementation is not contingent on other actions that are part of that alternative. APPENDIX I MAJOR MATERIAL DISPOSAL AREA REMEDIATION, CANYON CLEANUPS, AND OTHER CONSENT ORDER ACTIONS Los Alamos National Laboratory (LANL) conducts operations in support of the National Nuclear Security Administration (NNSA), a semi-autonomous administration within the U.S. Department

168

Alertness, performance and off-duty sleep on 8-hour and 12-hour night shifts in a simulated continuous operations control room setting  

SciTech Connect

A growing number of nuclear power plants in the United States have adopted routine 12-hr shift schedules. Because of the potential impact that extended work shifts could have on safe and efficient power plant operation, the U.S. Nuclear Regulatory Commission funded research on 8-hr and 12-hr shifts at the Human Alertness Research Center (HARC) in Boston, Massachusetts. This report describes the research undertaken: a study of simulated 8-hr and 12-hr work shifts that compares alertness, speed, and accuracy at responding to simulator alarms, and relative cognitive performance, self-rated mood and vigor, and sleep-wake patterns of 8-hr versus 12-hr shift workers.

Baker, T.L. [Institute for Circadian Physiology, Boston, MA (United States)

1995-04-01T23:59:59.000Z

169

Continuous Flow Liquid Microjunction Surface Sampling Probe Connected On-line with HPLC/MS for Spatially Resolved Analysis of Small Molecules and Proteins  

SciTech Connect

RATIONALE: A continuous flow liquid microjunction surface sampling probe extracts soluble material from surfaces for direct ionization and detection by MS. Demonstrated here is the on-line coupling of such a probe with HPLC/MS enabling extraction, separation and detection of small molecules and proteins from surfaces in a spatially resolved (~0.5 mm diameter spots) manner. Methods: A continuous flow liquid microjunction surface sampling probe was connected to a 6-port, 2-position valve for extract collection and injection to an HPLC column. A QTRAP 5500 hybrid triple quadrupole linear ion trap equipped with a Turbo V ion source operated in positive ESI mode was used for all experiments. System operation was tested with extraction, separation and detection of propranolol and associated metabolites from drug dosed tissues and proteins from dried sheep blood spots on paper. Results: Confirmed in the tissue were the parent drug and two different hydroxypropranolol glucuronides. The mass spectrometric response for these compounds from different locations in the liver showed an increase with increasing extraction time (5, 20 and 40 s extractions). For on-line separation and detection/identification of extracted proteins from dried sheep blood spots, two major protein peaks dominated the chromatogram and could be correlated with the expected masses for the hemoglobin and chains. Conclusions: Spatially resolved sampling, separation, and detection of small molecules and proteins from surfaces can be accomplished using a continuous flow liquid microjunction surface sampling probe coupled on-line with HPLC/MS detection.

Van Berkel, Gary J [ORNL; Kertesz, Vilmos [ORNL

2013-01-01T23:59:59.000Z

170

Amended NOI to Prepare an EIS for the Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapon Components  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

61 61 Federal Register / Vol. 60, No. 121 / Friday, June 23, 1995 / Notices operating facilities primarily or inherently devoted to religious instruction or worship, or engaging in any form of religious proselytization; and (7) providing a direct benefit to (a) a business organized for profit, (b) a labor union, (c) a partisan political organization, (d) a nonprofit organization that fails to comply with the restrictions contained in section 501(c) of the Internal Revenue Code of 1986, or (e) an organization engaged in the religious activities described in paragraph (6) above, unless Corporation assistance is not used to support those religious activities. Eligible Applicants Governors may apply on behalf of the following eligible entities: non-profit organizations, states, subdivisions of

171

Analysis of a transformer-less, multi-level DC-DC converter for HVDC operation  

SciTech Connect

HVDC systems require DC step up and DC step down units. The traditional approach is the application of twelve-pulse thyristor bridges with transformers. The developments of fast switching IGBT devices permit the development of transformer-less, multi-level converters. A multi-level circuit was suggested by Limpaecher. This paper presents a detailed simulation of the proposed circuit together with the analysis of its performance. The converter consists of a set of capacitors, air core inductors and solid state switches arranged in a ladder network. In the step-up mode, the closing of solid state switches resonantly charges the capacitors in parallel through an air-cored inductor. Then solid state switches resonantly charges the capacitors in parallel through an air-cored inductor. Then solid state switches connect the capacitors in series and discharge them through an air-core inductor to the load. In the step-down mode the capacitors are charged in series and discharged in parallel. The circuit has three modes of operation in each cycle: charge, inversion, and discharge. The circuit operation is analyzed in each mode using SPICE simulations. The selection of the components is discussed and output voltage regulation is analyzed. The results show that the proposed circuit promises significant reduction of losses, because of the zero current switching. The investment cost is reduced because of the elimination of transformers.

Karady, G.G.; Devarajan, S. [Arizona State Univ., Tempe, AZ (United States)

1998-12-31T23:59:59.000Z

172

TravInfo Evaluation (Technology Element) Traveler Information Center (TIC) Study: Operator Response Time Analysis  

E-Print Network (OSTI)

Traveler Information Center (TIC) Study Operator Inte$aceTraveler Information Center (TIC) Study Operator ZnterjizceInformation Center (TIC) Study (Technology Evaluation

Miller, Mark A.; Loukakos, Dimitri

2000-01-01T23:59:59.000Z

173

Economic Analysis of a Brackish Water Photovoltaic-Operated (BWRO-PV) Desalination System: Preprint  

SciTech Connect

The photovoltaic (PV)-powered reverse-osmosis (RO) desalination system is considered one of the most promising technologies in producing fresh water from both brackish and sea water, especially for small systems located in remote areas. We analyze the economic viability of a small PV-operated RO system with a capacity of 5 m3/day used to desalinate brackish water of 4000 ppm total dissolve solids, which is proposed to be installed in a remote area of the Babylon governorate in the middle of Iraq; this area possesses excellent insolation throughout the year. Our analysis predicts very good economic and environmental benefits of using this system. The lowest cost of fresh water achieved from using this system is US $3.98/ m3, which is very reasonable compared with the water cost reported by small-sized desalination plants installed in rural areas in other parts of the world. Our analysis shows that using this small system will prevent the release annually of 8,170 kg of CO2, 20.2 kg of CO, 2.23 kg of CH, 1.52 kg of particulate matter, 16.41 kg of SO2, and 180 kg of NOx.

Al-Karaghouli, A.; Kazmerski, L. L.

2010-10-01T23:59:59.000Z

174

EIS-0225-SA-05: Supplement Analysis | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Analysis Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapon Components, Texas This SA will enable DOE's NNSA to determine whether the existing...

175

Office for Analysis and Evaluation of Operational Data. Annual report, 1994-FY 95  

SciTech Connect

The United States Nuclear Regulatory Commission`s Office for Analysis and Evaluation of Operational Data (AEOD) has published reports of its activities since 1984. The first report covered January through June of 1984, and the second report covered July through December 1984. Since those first two semiannual reports, AEOD has published annual reports of its activities from 1985 through 1993. Beginning with the report for 1986, AEOD Annual Reports have been published as NUREG-1272. Beginning with the report for 1987, NUREG-1272 has been published in two parts, No. 1 covering power reactors and No. 2 covering nonreactors (changed to {open_quotes}nuclear materials{close_quotes} with the 1993 report). The 1993 AEOD Annual Report was NUREG-1272, Volume 8. AEOD has changed its annual report from a calendar year to a fiscal year report to be consistent with the NRC Annual Report and to conserve staff resources. NUREG-1272, Volume 9, No. 1 and No. 2, therefore, are combined calendar year 1994 (1994) and fiscal year 1995 (FY 95) reports which describe activities conducted between January 1, 1994, and September 30, 1995. Certain data which have historically been reported on a calendar year basis, however, are complete through calendar year 1995. Throughout this report, whenever information is presented for fiscal year 1995, it is designated as FY 95 data. Calendar year information is always designated by the four digits of the calendar year. This report, NUREG-1272, Volume 9, No. 1, covers power reactors and presents an overview of the operating experience of the nuclear power industry from the NRC perspective. NUREG-1272, Vol. 9, No. 2, covers nuclear materials and presents a review of the events and concerns associated with the use of licensed material in non-power reactor applications. A new part has been added, NUREG-1272, Volume 9, No. 3, which covers technical training and presents the activities of the Technical Training Center in FY 95 in support of the NRC`s mission.

none,

1996-07-01T23:59:59.000Z

176

Work Domain Analysis of a Predecessor Sodium-cooled Reactor as Baseline for AdvSMR Operational Concepts  

SciTech Connect

This report presents the results of the Work Domain Analysis for the Experimental Breeder Reactor (EBR-II). This is part of the phase of the research designed to incorporate Cognitive Work Analysis in the development of a framework for the formalization of an Operational Concept (OpsCon) for Advanced Small Modular Reactors (AdvSMRs). For a new AdvSMR design, information obtained through Cognitive Work Analysis, combined with human performance criteria, can and should be used in during the operational phase of a plant to assess the crew performance aspects associated with identified AdvSMR operational concepts. The main objective of this phase was to develop an analytical and descriptive framework that will help systems and human factors engineers to understand the design and operational requirements of the emerging generation of small, advanced, multi-modular reactors. Using EBR-II as a predecessor to emerging sodium-cooled reactor designs required the application of a method suitable to the structured and systematic analysis of the plant to assist in identifying key features of the work associated with it and to clarify the operational and other constraints. The analysis included the identification and description of operating scenarios that were considered characteristic of this type of nuclear power plant. This is an invaluable aspect of Operational Concept development since it typically reveals aspects of future plant configurations that will have an impact on operations. These include, for example, the effect of core design, different coolants, reactor-to-power conversion unit ratios, modular plant layout, modular versus central control rooms, plant siting, and many more. Multi-modular plants in particular are expected to have a significant impact on overall OpsCon in general, and human performance in particular. To support unconventional modes of operation, the modern control room of a multi-module plant would typically require advanced HSIs that would provide sophisticated operational information visualization, coupled with adaptive automation schemes and operator support systems to reduce complexity. These all have to be mapped at some point to human performance requirements. The EBR-II results will be used as a baseline that will be extrapolated in the extended Cognitive Work Analysis phase to the analysis of a selected advanced sodium-cooled SMR design as a way to establish non-conventional operational concepts. The Work Domain Analysis results achieved during this phase have not only established an organizing and analytical framework for describing existing sociotechnical systems, but have also indicated that the method is particularly suited to the analysis of prospective and immature designs. The results of the EBR-II Work Domain Analysis have indicated that the methodology is scientifically sound and generalizable to any operating environment.

Ronald Farris; David Gertman; Jacques Hugo

2014-03-01T23:59:59.000Z

177

Eigenvalue Analysis of a DFIG Based Wind Power System under Different Modes of Operations  

Science Journals Connector (OSTI)

This chapter discussed the various mode of operation of the Doubly Fed Induction Generator (DFIG) based wind farm system. The impact ... on the different modes of operation for the DFIG based wind generation syst...

Y. Mishra; S. Mishra; Fangxing Li; Z. Y. Dong

2010-01-01T23:59:59.000Z

178

A Posteriori Analysis of Adaptive Multiscale Operator Decomposition Methods for Multiphysics Problems  

SciTech Connect

This project was concerned with the accurate computational error estimation for numerical solutions of multiphysics, multiscale systems that couple different physical processes acting across a large range of scales relevant to the interests of the DOE. Multiscale, multiphysics models are characterized by intimate interactions between different physics across a wide range of scales. This poses significant computational challenges addressed by the proposal, including: (1) Accurate and efficient computation; (2) Complex stability; and (3) Linking different physics. The research in this project focused on Multiscale Operator Decomposition methods for solving multiphysics problems. The general approach is to decompose a multiphysics problem into components involving simpler physics over a relatively limited range of scales, and then to seek the solution of the entire system through some sort of iterative procedure involving solutions of the individual components. MOD is a very widely used technique for solving multiphysics, multiscale problems; it is heavily used throughout the DOE computational landscape. This project made a major advance in the analysis of the solution of multiscale, multiphysics problems.

Donald Estep; Michael Holst; Simon Tavener

2010-02-08T23:59:59.000Z

179

Nonlinear dynamics analysis of a membrane Stirling engine: Starting and stable operation  

E-Print Network (OSTI)

This paper presents the work devoted to the study of the operation of a miniaturized membrane Stirling engine. Indeed, such an engine relies on the dynamic coupling of the motion of two membranes to achieve a prime mover Stirling thermodynamic cycle. The modelling of the system introduces the large vibration amplitudes of the membrane as well as the nonlinear dissipative effects associated to the fluid flow within the engine. The nonlinearities are expressed as polynomial functions with quadratic and cubic terms. This paper displays the stability analysis to predict the starting of the engine and the instability problem which leads to the steady state behaviour. The centre manifold - normal form theory is used to obtain the simplest expression for the limit cycle amplitudes. The approach allows the reduction of the number of equations of the original system in order to obtain a simplified system, without loosing the dynamics of the original system as well as the contributions of non-linear terms. The model in...

Formosa, Fabien

2013-01-01T23:59:59.000Z

180

LoanSTAR Monitoring and Analysis Program: Presentation Summary of the State Capitol Complex Building Operation and Maintenance Field Test  

E-Print Network (OSTI)

requests, only 58% to 95% of AHUs identified in earlier report were shut off S. F. Austin Whole Building Electricity & Chilled Water Consumption Over 600 kW reduction when AHUs and lights turned off L.B. Johnson Whole Building Electricity & Chilled Water...LoanSTAR Monitoring and Analysis Program Presentation Summary of the State Capitol Complex Building Operation and Maintenance Field Test Presented to the State Purchasing and General Services Commission By the Monitoring Analysis Task E Dr. W. D...

Turner, W. D.; Houcek, J. K.; Liu, M.; Claridge, D. E.

1993-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Extension of Comment Period on the Draft Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory, Los Alamos, NM (DOE/EIS-0380) (08/31/06)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

10 Federal Register 10 Federal Register / Vol. 71, No. 169 / Thursday, August 31, 2006 / Notices Coordinator, at the address and phone number listed above. Issued at Washington, DC on August 24, 2006. Carol Matthews, Acting Advisory Committee Management Officer. [FR Doc. 06-7304 Filed 8-30-06; 8:45 am] BILLING CODE 6450-01-P DEPARTMENT OF ENERGY National Nuclear Security Administration Extension of Comment Period on the Draft Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory, Los Alamos, NM AGENCY: U.S. Department of Energy (DOE), National Nuclear Security Administration (NNSA). ACTION: Notice of comment period extension. SUMMARY: On July 7, 2006, NNSA published a Notice of Availability for the Draft Site-wide Environmental

182

Analysis of the Impact of Balancing Area Cooperation on the Operation of the Western Interconnection with Wind and Solar Generation (Presentation)  

SciTech Connect

This presentation describes the analysis of the impact of balancing area cooperation on the operation of the Western Interconnection with wind and solar generation, including a discussion of operating reserves, ramping, production simulation, and conclusions.

Milligan, M.; Lew, D.; Jordan, G.; Piwko, R.; Kirby, B.; King, J.; Beuning, S.

2011-05-01T23:59:59.000Z

183

Statistical analysis of operational reliability for electric pump units CN 60–180 of VVER-1000 reactors with root estimation methods  

Science Journals Connector (OSTI)

We consider the problem of processing statistical data obtained during the operation of pumping units CN 60–180 operating as standard equipment of the VVER-1000 reactors. Data for analysis was taken from the indu...

A. V. Antonov; V. A. Chepurko; N. G. Zyulyaeva…

2010-07-01T23:59:59.000Z

184

Design, Construction, Transportation, Operation and Post-Occupancy Analysis for the Texas A&M Solar Decathlon House  

E-Print Network (OSTI)

This paper describes the design, construction, transportation, operation and post occupancy analysis of the 2007 Texas A&M Solar Decathlon House (TAMU SD house). The TAMU SD house was developed to be a modular house that could grow into varying...

Malhotra, M.; Ramirez, E.; Im, P.; Cho, S.; Canez, J.; Haberl, J.; Schaider, N.; Fisk, P.; Feigenbaum, L.

185

Systems Modeling and Analysis Industrial Engineers are interested in optimizing the design and operation of complex systems  

E-Print Network (OSTI)

and operation of complex systems composed of people and machines using information, materials and energySystems Modeling and Analysis Industrial Engineers are interested in optimizing the design to produce goods and services. Analyzing such systems with information-driven models is an essential step

Dyer, Bill

186

Both construction and operations continue to increase  

NLE Websites -- All DOE Office Websites (Extended Search)

of these young girls was Gladys Owens who is prominently featured in the famous Ed Westcott photograph of the "Calutron Girls." She is the person in the right foreground. Gladys...

187

Microsoft Word - Environmental Document for Continued Operation...  

National Nuclear Security Administration (NNSA)

(enter East Gate on Greenville Road), and the following websites: DOE website: http:www.doeal.govlso Laboratory website: https:www-envirinfo.llnl.govenviroRecent.php -30-...

188

Analysis of potential impacts to resident fish from Columbia River System Operation alternatives  

Science Journals Connector (OSTI)

The US Army Corps of Engineers, the US Bureau of Reclamation, and the Bonneville Power Administration initiated the Columbia River System Operation Review...

David R. Geist; Lance W. Vail; Daniel J. Epstein

189

Survey Results and Analysis of the Cost and Efficiency of Various Operating Hydrogen Fueling Stations  

SciTech Connect

Existing Hydrogen Fueling Stations were surveyed to determine capital and operational costs. Recommendations for cost reduction in future stations and for research were developed.

Cornish, John

2011-03-05T23:59:59.000Z

190

Continuous Flow Multi-Step Organic Synthesis  

E-Print Network (OSTI)

Using continuous flow techniques for multi-step synthesis enables multiple reaction steps to be combined into a single continuous operation. In this mini-review we discuss the current state of the art in this field and ...

Webb, Damien

191

Life Cycle cost Analysis of Waste Heat Operated Absorption Cooling Systems for Building HVAC Applications  

E-Print Network (OSTI)

was used to calculate the PWC of the system for annual operating hours of 8760 and the same is compared with the electric based vapour compression chiller (VCRS) of same capacity. The life cycle cost (LCC) of waste heat operated absorption chiller...

Saravanan, R.; Murugavel, V.

2010-01-01T23:59:59.000Z

192

An adaptive simulation model for analysis of nuclear material shipping operations  

SciTech Connect

Los Alamos has developed an advanced simulation environment designed specifically for nuclear materials operations. This process-level simulation package, the Process Modeling System (ProMoS), is based on high-fidelity material balance criteria and contains intrinsic mechanisms for waste and recycle flows, contaminant estimation and tracking, and material-constrained operations. Recent development efforts have focused on coupling complex personnel interactions, personnel exposure calculations, and stochastic process-personnel performance criteria to the material-balance simulation. This combination of capabilities allows for more realistic simulation of nuclear material handling operations where complex personnel interactions are required. They have used ProMoS to assess fissile material shipping performance characteristics at the Los Alamos National Laboratory plutonium facility (TA-55). Nuclear material shipping operations are ubiquitous in the DOE complex and require the largest suite of varied personnel interacting in a well-timed manner to accomplish the task. They have developed a baseline simulation of the present operations and have estimated the operational impacts and requirement of the pit production mission at TA-55 as a result of the SSM-PEIS. Potential bottlenecks have been explored and mechanisms for increasing operational efficiency are identified.

Boerigter, S.T.; Sena, D.J.; Fasel, J.H.

1998-12-31T23:59:59.000Z

193

Reliability analysis of urban gas transmission and distribution system based on FMEA and correlation operator  

Science Journals Connector (OSTI)

In order to improve the safety management of urban gas transmission and distribution system, failure mode and effects analysis (FMEA) was used to construct the reliability analysis ... the risk priority number (R...

Su Li; Weiguo Zhou

2014-12-01T23:59:59.000Z

194

Impact of a Revised Analysis Algorithm on an Operational Data Assimilation System  

Science Journals Connector (OSTI)

The improvement of analysis and data assimilation techniques can have a large impact, as shown here in the context of the Canadian global and regional data assimilation systems. Both of these systems utilize the same analysis component that was ...

Herschel L. Mitchell; Clément Chouinard; Cécilien Charette; Richard Hogue; Steven J. Lambert

1996-06-01T23:59:59.000Z

195

CAMEA ESS - The Continuous Angle Multi-Energy Analysis Indirect Geometry Spectrometer for the European Spallation Source  

E-Print Network (OSTI)

The CAMEA ESS neutron spectrometer is designed to achieve a high detection efficiency in the horizontal scattering plane, and to maximize the use of the long pulse European Spallation Source. It is an indirect geometry time-of-flight spectrometer that uses crystal analysers to determine the final energy of neutrons scattered from the sample. Unlike other indirect gemeotry spectrometers CAMEA will use ten concentric arcs of analysers to analyse scattered neutrons at ten different final energies, which can be increased to 30 final energies by use of prismatic analysis. In this report we will outline the CAMEA instrument concept, the large performance gain, and the potential scientific advancements that can be made with this instrument.

Freeman, P G; Markó, M; Bertelsen, M; Larsen, J; Christensen, N B; Lefmann, K; Jacobsen, J; Niedermayer, Ch; Juranyi, F; Ronnow, H M

2014-01-01T23:59:59.000Z

196

The Operation Management and Energy Consumption Analysis of the District Cooling System  

E-Print Network (OSTI)

Based on the investigation of the district cooling system of the Zhongguancun Square in Beijing, we thoroughly analyzed the process of its operation management and the main factors that affect energy consumption. The basis was provided...

Xu, Q.; Li, D.; Xu, W.

2006-01-01T23:59:59.000Z

197

Entropic analysis of a dual-mode scramjet engine for system performance/operability enhancement .  

E-Print Network (OSTI)

??"Recent analytical advances in understanding the performance range (thermodynamic spectrum) for air-breathing engines based upon fundamental second-law considerations have clarified scramjet and ramjet operation, performance,… (more)

Tackett, Regan, 1978-

2007-01-01T23:59:59.000Z

198

Trav Info Evaluation ( Technology Element ) Traveler Information Center ( TIC ) Study: Operator Interface Analysis - Phase III  

E-Print Network (OSTI)

and evaluator visits to the TIC. The objective of this workthe different aspects of the TIC working environment. Thecontribute to or hinder the TIC operatorÕs job performance.

Miller, Mark; Loukakos, Dimitri

1998-01-01T23:59:59.000Z

199

Observation and analysis of departure operations at Boston Logan International Airport  

E-Print Network (OSTI)

In order to support the development of improved methods for departure operations, the flow constraints and their causalities --primarily responsible for inefficiencies and delays-- need to be identified. This thesis is an ...

Idris, Husni Rifat

2001-01-01T23:59:59.000Z

200

Observation and Analysis of Departure Planning Operations at Boston Logan International Airport  

E-Print Network (OSTI)

The Departure Planner (DP) is a concept for a decision-aiding tool that is aimed at improving the departure operations performance at major congested airports. In order to support the development of the DP tool, the flow ...

Idris, Husni R.

2011-10-14T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Network Operation and Maintenance System of Meticulous Management Based on Data Analysis  

Science Journals Connector (OSTI)

Due to rapid development of the domestic communication industry, energy consumption on network operation and maintenance has become one of the ... s crucial for us to develop an intelligent system for data analys...

Qi-Te Wang; Ke-Bin Jia; Ye Yuan; Yu-Xin Song

2014-01-01T23:59:59.000Z

202

Surface Spectral Albedo Intensive Operational Period at the ARM SGP Site in august 2002: Results, Analysis, and Future Plans  

NLE Websites -- All DOE Office Websites (Extended Search)

Spectral Albedo Intensive Operational Period Spectral Albedo Intensive Operational Period at the ARM SGP Site in August 2002: Results, Analysis, and Future Plans A. P. Trishchenko and Y. Luo Canada Centre for Remote Sensing Ottawa, Ontario, Canada M. C. Cribb and Z. Li University of Maryland College Park, Maryland K. Hamm University of Oklahoma Norman, Oklahoma Introduction A surface spectral albedo Intensive Operational Period (IOP) at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site was conducted during August 14-19, 2002, to meet the ARM Program need in a detailed knowledge of surface boundary conditions for atmospheric radiation studies. We measured surface spectral albedos/reflectances for several representative surface types and made a survey of landcover types over an area of approximately 10 km x 10 km centered

203

Report to the US Nuclear Regulatory Commission on analysis and evaluation of operational data - 1987: Power reactors  

SciTech Connect

This annual report of the US Nuclear Regulatory Commission's Office for Analysis and Evaluation of Operational Data (AEOD) is devoted to the activities performed during 1987. The report is published in two volumes. NUREG-1272, Vol. 2, No. 1, covers Power Reactors and presents an overview of the operating experience of the nuclear power industry, with comments regarding the trends of some key performance measures. The report also includes the principal findings and issues identified in AEOD studies over the past year, and summarizes information from Licensee Event Reports, the NRC's Operations Center, and Diagnostic Evaluations. NUREG-1272, Vol. 2, No. 2, covers Nonreactors and presents a review of the nonreactors events and misadministration reports that were reported in 1987 and a brief synopsis of AEOD studies published in 1987. Each volume contains a list of the AEOD Reports issued for 1980-1987.

none,

1988-10-01T23:59:59.000Z

204

Joint-Frequency Bins versus Conventional Bin Weather Data in Analysis of HVAC System Operation  

E-Print Network (OSTI)

Often in simplified energy analysis the use of bin weather data is employed for a more time efficient and better organized analysis than using the full 8760-hour annual weather data. It has been suggested that joint-frequency bins be used instead...

Jones, A.; Baltazar, J. C.; Claridge, D. E.

205

Simulation of a continuous rotary dissolver  

SciTech Connect

This paper describes the simulation of a rotating, multistage chemical reactor that dissolves spent nuclear fuel for reprocessing in a breeder cycle. The continuous, time-dependent process model of a dissolver was developed using the Advanced Continuous Simulation Language (ACSL) to calculate various temperatures and the masses of the chemical constituents of the solution in each stage. The Gear integration algorithm (Gear 1971) was used to accommodate the stiff dynamics. An arrangement of interacting discrete sections was employed to cause fresh fuel to be added and dissolver rotations to occur at appropriate times. By changing various constants, the model can simulate the effect of different fuel compositions and operational scenarios. The model code is a valuable tool for analysis of the performance of the dissolution system and has been instrumental in its design. 5 refs., 7 figs.

Carnal, C.L.; Hardy, J.E.; Lewis, B.E.

1989-01-01T23:59:59.000Z

206

Impact of Operational Practices on Rail Line Capacity: A Simulation Analysis  

E-Print Network (OSTI)

@illinois.edu, yclai@ntu.edu.tw, cbarkan@illinois.edu ABSTRACT Long-term demand for freight and passenger is critical for cost-effective planning of new capacity. A key aspect of this is the effect of heterogeneous conducted to evaluate the effectiveness of various operational changes to reduce delays. The trade

Barkan, Christopher P.L.

207

Threshold analysis with fault-tolerant operations for nonbinary quantum error correcting codes  

E-Print Network (OSTI)

possibility of catastrophic spread of errors which might render the error correction techniques ineffective. Hence, in this thesis we concentrate on how various operations can be carried out fault-tolerantly so that the errors are not propagated in the same...

Kanungo, Aparna

2005-11-01T23:59:59.000Z

208

Ensemble operational air quality assessments in Europe Improving modeling platforms with statistical analysis  

E-Print Network (OSTI)

Ensemble operational air quality assessments in Europe ­ Improving modeling platforms. For regional air quality, seven regional modeling teams combine state-of-the-art atmospheric modeling the ensemble or a unique model. Keywords: Air quality, modeling system, ensemble approach, validation

Paris-Sud XI, Université de

209

A Complexity Science-Based Framework for Global Joint Operations Analysis to Support Force Projection: LDRD Final Report.  

SciTech Connect

The military is undergoing a significant transformation as it modernizes for the information age and adapts to address an emerging asymmetric threat beyond traditional cold war era adversaries. Techniques such as traditional large-scale, joint services war gaming analysis are no longer adequate to support program evaluation activities and mission planning analysis at the enterprise level because the operating environment is evolving too quickly. New analytical capabilities are necessary to address modernization of the Department of Defense (DoD) enterprise. This presents significant opportunity to Sandia in supporting the nation at this transformational enterprise scale. Although Sandia has significant experience with engineering system of systems (SoS) and Complex Adaptive System of Systems (CASoS), significant fundamental research is required to develop modeling, simulation and analysis capabilities at the enterprise scale. This report documents an enterprise modeling framework which will enable senior level decision makers to better understand their enterprise and required future investments.

Lawton, Craig R.

2015-01-01T23:59:59.000Z

210

Concrete Security Analysis of CTR-OFB and CTR-CFB Modes of Operation  

Science Journals Connector (OSTI)

In [1...], they gave the notions of security for the symmetric encryption and provided a concrete security analysis of the XOR, CTR, and CBC schemes. Among the three schemes, the CTR scheme achieves the best conc...

Jaechul Sung; Sangjin Lee; Jongin Lim…

2002-01-01T23:59:59.000Z

211

Annals of Operations Research 30 (1991) 169-186 169 ASYMPTOTIC ANALYSIS OF STOCHASTIC PROGRAMS  

E-Print Network (OSTI)

. c,5J.C. Baltzer A.G. Scientific Publishing Company #12;170 A. Shapiro / Asymptotic analysis Alexander SHAPIRO Department of Mathematics and Applied Mathematics. Uniuersitv of South Africa. Pretoria

Shapiro, Alex

212

Analysis of efficiency of control of operation conditions of air gas cooling devices at compressor stations  

Science Journals Connector (OSTI)

Based on calculations of energy consumption by air gas cooling devices, an analysis has been made of the efficiency of the methods of control of temperature conditions of the transported gas. Two types of air ...

A. V. Krupnikov; A. D. Vanyashov; I. A. Yanvarev

2010-05-01T23:59:59.000Z

213

Analysis of operating data related to power and flow distribution in a PWR  

E-Print Network (OSTI)

The analysis of the effects of the uncertainties associated with temperature and power measurements in the Connecticut Yankee Reactor leads to the evaluation of the uncertainty associated with the effective flow factor. ...

Herbin, Henry Christophe

1974-01-01T23:59:59.000Z

214

Analysis, Design, and Operation of a Spherical Inverted-F Antenna  

E-Print Network (OSTI)

This thesis presents the analysis, design, and fabrication of a spherical inverted-F antenna (SIFA). The SIFA consists of a spherically conformal rectangular patch antenna recessed into a quarter section of a metallic sphere. The sphere acts as a...

McDonald, Jacob J.

2010-07-14T23:59:59.000Z

215

CERTS 2012 Program Review - Modal Analysis for Grid Operations (MANGO) - Henry Huang, PNNL  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Henry Huang, Ning Zhou, Ruisheng Diao, Frank Tuffner Dan Trudnowski (Montana Tech) Pacific Northwest National Laboratory zhenyu.huang@pnnl.gov 12/13 June 2011 Washington, DC OE Transmission Reliability Internal Review Past Oscillation Event - 1996/08/10 [bitmap version 1100 1200 1300 1400 1500 15:42:03 15:48:51 15:47:36 Power (MW) August 10, 1996 Western Power System Breakup California-Oregon Intertie Time Domain ~ -3.1% < ~3.5% Damping ~ 8.4% Early Warning ~6 minutes Freq Domain Project Objective  Ways to Improve Damping - Power System Stabilizer (PSS): parameters pre-tuned based on off-line scenarios - Reactive Support: locations pre-selected based on off-line scenarios - Operating Point Adjustment: operator actions determined with the on-line

216

Semiclassical analysis for a Schrödinger operator with a U(2) artificial gauge: the periodic case  

E-Print Network (OSTI)

We consider a Schr\\"odinger operator with a Hermitian 2x2 matrix-valued potential which is lattice periodic and can be diagonalized smoothly on the whole $R^n.$ In the case of potential taking its minimum only on the lattice, we prove that the well-known semiclassical asymptotic of first band spectrum for a scalar potential remains valid for our model.

Abderemane Morame; Francoise Truc

2014-01-24T23:59:59.000Z

217

Deutsch-Jozsa algorithm for continuous variables  

E-Print Network (OSTI)

We present an idealized quantum continuous variable analog of the Deutsch-Jozsa algorithm which can be implemented on a perfect continuous variable quantum computer. Using the Fourier transformation and XOR gate appropriate for continuous spectra we show that under ideal operation to infinite precision that there is an infinite reduction in number of query calls in this scheme.

Arun K. Pati; Samuel L. Braunstein

2002-07-18T23:59:59.000Z

218

Supplement Analysis of Site-Specific and Programmatic Environmental Impact Statements: Operational and Engineering Modifications, Regulatory Review, and Socioeconomic Variation  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DISCLAIMER DISCLAIMER This document has been approved for distribution to the public. All information classified by the Department of Energy Strategic Petroleum Reserve as Sensitive Unclassified Information has been removed from this document. DOE/SPR/EIS-0075-SA01 SUPPLEMENT ANALYSIS OF SITE-SPECIFIC AND PROGRAMMATIC ENVIRONMENTAL IMPACT STATEMENTS: OPERATIONAL AND ENGINEERING MODIFICATIONS, REGULATORY REVIEW, AND SOCIOECONOMIC VARIATION U.S. Department of Energy Strategic Petroleum Reserve 900 Commerce Road East New Orleans, Louisiana 70123 March 2004 Prepared for the U. S. Department of Energy Strategic Petroleum Reserve Project Management Office under Contract No. DE-AC96-93PO92207 DynMcDermott Petroleum Operations Company 850 South Clearview Parkway

219

Analysis of radiation exposure for troop observers, Exercise Desert Rock VI, Operation Teapot. Final report 1 Mar-15 Jul 80  

SciTech Connect

The radiation doses to troop observers and volunteer observers for Exercise Desert Rock VI are reconstructed for each applicable shot of Operation Teapot (1955). Initial neutron and gamma radiation doses are determined from transport codes ATR4 and ATR4.1. Residual radiation contours and decay rates are established through a new automated procedure that utilizes raw data in regression analysis to fit space-time models. Troop operations data are combined with the radiological data to determine integrated dose. Uncertainties are calculated for each parameter. The volunteers received the highest observer--1.6 rem gamma and 4.5 rem neutron. The highest dose received by troop observers was 1.4 rem gamma and 1.4 rem neutron at Shot Tesla.

Goetz, J.; McGahan, J.; Kaul, D.; Weitz, R.; Klemm, J.

1980-07-15T23:59:59.000Z

220

Preliminary Accident Analysis for Construction and Operation of the Chornobyl New Safety Confinement  

SciTech Connect

Analysis of potential exposure of personal and population during construction and exploitation of the New Safe Confinement was made. Scenarios of hazard event development were ranked. It is shown, that as a whole construction and exploitation of the NSC are in accordance with actual radiation safety norms of Ukraine.

Batiy, Valeriy; Rubezhansky, Yruiy; Rudko, Vladimir; shcherbin, vladimir; Yegorov, V; Schmieman, Eric A.; Timmins, Douglas C.

2005-08-08T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Analysis of radiation exposure for naval personnel at Operation Ivy. Technical report  

SciTech Connect

The radiological environments are reconstructed for eighteen ships and the residence islands of Enewetak, Kwajalein, and Bikini Atolls that received fallout following Shots MIKE and KING during Operation IVY (November 1952). Secondary (late-time) fallout from Shot MIKE was the primary contributor to the low-level radiation encountered on the majority of the ships and atolls; only the M/V HORIZON received primary (early-time) fallout from this event. Fallout from Shot KING was minimal. From the reconstructed operations and radiological environments, equivalent personnel film badge doses are calculated and compared with available dosimetry data for fourteen of the ships. Calculated doses for the majority of the ships are in good agreement with the film badge data; however, for three of the participating destroyers (DDEs), calculated doses are significantly lower than the dosimetry data indicates. Calculated mean doses for typical shipboard personnel range from a high of 0.062 rem on the HORIZON to a low of 0.001 rem on the SPENCER F. BAIRD; for island-based personnel, calculated mean doses are less than 0.06 rem.

Thomas, C.; Goetz, J.; Stuart, J.; Klemm, J.

1983-03-15T23:59:59.000Z

222

A Dynamic Performance Analysis on CANDU Fuel Handling System for Operational Improvement  

SciTech Connect

The dynamic performance of the Fueling Machine (F/M) Heavy Water (D{sub 2}O) supply system for Wolsong Nuclear Power Plant (NPP) was evaluated using Modular Modeling System (MMS) computer code. Parametric study has been carried out to investigate the effects of dual common set pressure and the position change rate of series valve on the dynamic behavior of common header pressure and common bleed valve position during the mode changes of supply pressure. The results show that the introduction of the series valve position demand curve and the dual common header set pressure is effective to attenuate the overshoot of common header pressure during mode changes. This does not lead any adverse effects on the system performance of supply pressure control and heavy water supply to F/M during the mode changes. The dynamic evaluation results of the F/M D{sub 2}O supply system will be used for the new control system parameter settings and help to relieve system operators' burdens during the system operation. (authors)

Jeong Mann Kim; Byung Ryul Jung [Korea Power Engineering Company, Inc, 360 9 Mabuk Dong, Giheung-gu Yongin-si, Gyeonggi-do 449-713 (Korea, Republic of); Wan Kyu Park [Korea Hydro and Nuclear Power Company, 167 Samseong-dong, Kangnam-gu, Seoul 135-791 (Korea, Republic of)

2002-07-01T23:59:59.000Z

223

Analysis of radiation exposure, Task Force RAZOR. Exercise Desert Rock VI, Operation Teapot. Technical report  

SciTech Connect

The radiation dose to Task Force RAZOR personnel participating in Shot Apple II of Operation Teapot, Exercise Desert Rock VI, is reconstructed. Task force personnel were exposed to initial radiation while in their vehicles or in trenches at the time of Apple II detonation. They were also exposed to residual radiation during their subsequent manuever and during an inspection of the equipment display area. The calculated total gamma doses to fully-participating Task Force RAZOR personnel range from about 0.8 rem to 1.8 rem. The highest dose was received by personnel of the armored infantry platoon on right flank nearest ground zero. Internal radiation dose commitments to maximally exposed personnel inside vehicles are estimated to be about 0.4 rem to the thyroid, 0.003 rem to the whole body, and 0.002 rem to the bone.

Edwards, R.; Goetz, J.; Klemm, J.

1983-07-15T23:59:59.000Z

224

Experimental analysis of a diesel engine operating in Diesel–Ethanol Dual-Fuel mode  

Science Journals Connector (OSTI)

Abstract The use of engines is necessary to keep the world moving. Such engines are fed mainly by fossil fuels, among these, the diesel. The operation and the behavior of engines in different thermodynamic cycles, with common fossil fuels, it is still challenging but, in general, it has well known and documented data. On the other hand, for alternative fuels, there is still demand of experimental data, particularly considering that it is desirable, most of the times, the use of a system with dual mode (reversible). Such systems are called Dual-Fuel, it brings a greater degree of freedom, but imply in technological challenges. In this paper we used an engine operating with single cylinder direct injection diesel and port ethanol injection system in Dual-Fuel mode with a 100% electronically controlled calibration. The methodology applied was, once the engine calibration was given to achieve the best specific fuel consumption or the MBT (Maximum Brake Torque) in each load condition, to gradually substitute the diesel oil by ethanol in compliance with the requirements established. Comparisons were made among working conditions considering the rate of diesel substitution and the energy indicated efficiency. Initially, the flow structure in the combustion chamber was tested in both ‘quiescent’ and high “swirl” modes. Compression ratios were adjusted at 3 different levels: 14:1, 16:1 and 17:1. It was tested two injectors, the first one of 35 g/s and another of 45 g/s. Regarding pressure diesel injection, 4 levels were investigated namely 800, 1000, 1200 and 1400 bar.

Roberto Freitas Britto Jr.; Cristiane Aparecida Martins

2014-01-01T23:59:59.000Z

225

Probabilistic analysis and operational data in response to NUREG-0737, Item II. K. 3. 2 for Westinghouse NSSS plants. [Modifications to reduce LOCA due to stuck-open power-operated relief valve  

SciTech Connect

This report describes various modifications to Westinghouse plants since TMI and, using probabilistic analysis via event trees, estimates the effect of the post-TMI changes, including an automatic (PORV) (power operated relief valve) isolation concept identified in NUREG-0731 item II.K.3.1. The requested safety valve operational data is included as an appendix. A significant reduction in the frequency of a small break LOCA, due to a stuck open PORV has already been achieved by the modifications made subsequent to TMI. Domestic Westinghouse operating plant data (based on 181 reactor years of operation) has been collected and evaluated. An auto block valve closure system has been evaluated. The analysis is generally applicable to all Westinghouse plants which have incorporated the post-TMI hardware and procedural changes relative to stuck-open PORVs.

Wood, D.C.; Gottshall, C.L.

1981-02-01T23:59:59.000Z

226

Assessing the Impacts of Reduced Noise Operations of Wind Turbines on Neighbor Annoyance: A Preliminary Analysis in Vinalhaven, Maine  

E-Print Network (OSTI)

Noise Operations of Wind Turbines on Neighbor Annoyance: ANoise Operations of Wind Turbines on Neighbor Annoyance: A

Hoen, Ben

2010-01-01T23:59:59.000Z

227

Office for Analysis and Evaluation of Operational Data 1996 annual report. Volume 10, Number 3: Technical training  

SciTech Connect

This annual report of the US Nuclear Regulatory Commission`s Office for Analysis and Evaluation of Operational Data (AEOD) describes activities conducted during 1996. The report is published in three parts. NUREG-1272, Vol. 10, No. 1, covers power reactors and presents an overview of the operating experience of the nuclear power industry from the NRC perspective, including comments about trends of some key performance measures. The report also includes the principal findings and issues identified in AEOD studies over the past year and summarizes information from such sources as licensee event reports and reports to the NRC`s Operations Center. NUREG-1272, Vol. 10, No. 2, covers nuclear materials and presents a review of the events and concerns during 1996 associated with the use of licensed material in nonreactor applications, such as personnel overexposures and medical misadministrations. Both reports also contain a discussion of the Incident Investigation Team program and summarize both the Incident Investigation Team and Augmented Inspection Team reports. Each volume contains a list of the AEOD reports issued from CY 1980 through 1996. NUREG-1272, Vol. 10, No. 3, covers technical training and presents the activities of the Technical Training Center in support of the NRC`s mission in 1996.

NONE

1997-12-01T23:59:59.000Z

228

Office for Analysis and Evaluation of Operational Data 1992 annual report: Power reactors. Volume 7, No. 1  

SciTech Connect

The annual report of the US Nuclear Regulatory Commission`s Office for Analysis and Evaluation of Operational Data (AEOD) is devoted to the activities performed during 1992. The report is published in two separate parts. NUREG-1272, Vol. 7, No. 1, covers power reactors and presents an overview of the operating experience of the nuclear power industry from the NRC perspective, including comments about the trends of some key performance, measures. The report also includes the principal findings and issues identified in AEOD studies over the past year, and summarizes information from such sources as licensee event report% diagnostic evaluations, and reports to the NRC`s Operations Center. The reports contain a discussion of the Incident Investigation Team program and summarize the Incident Investigation Team and Augmented Inspection Team reports for that group of licensees. NUREG-1272, Vol. 7, No. 2, covers nonreactors and presents a review of the events and concerns during 1992 associated with the use of licensed material in nonreactor applications, such as personnel overexposures and medical misadministrations. Each volume contains a list of the AEOD reports issued for 1984--1992.

none,

1993-07-01T23:59:59.000Z

229

Experimental performance analysis of a solar assisted ground source heat pump system under different heating operation modes  

Science Journals Connector (OSTI)

Abstract This paper presents an experimental study on the influence of operation modes on the heating performance of a solar assisted ground source heat pump system (SAGSHPS). Through experiments conducted in January, the characteristics of the SAGSHPS were investigated under different heating operation modes. The results indicate that the solar thermal could be used to accelerate the soil recovery when the heat pump unit is turned off, but the duration of solar use to recharge boreholes should be optimized according to the water temperature in the solar heat storage water tank to avoid unnecessary power consumption of the circulation pump. In addition, the solar heat storage water tank is beneficial for the stable operation of the SAGSHPS. The volumetric flow rate in the water tank has a significant impact on the electricity consumption of the SAGSHPS. From comprehensive analysis of the integral effect of the SAGSHPS under different modes, the mode in which the water tank is connected with the ground heat exchangers (GHES) in series is the recommended mode for the SAGSHPS in the coldest month in Dalian.

Lanhua Dai; Sufen Li; Lin DuanMu; Xiangli Li; Yan Shang; Ming Dong

2015-01-01T23:59:59.000Z

230

Dynamic Analysis of Hybrid Energy Systems under Flexible Operation and Variable Renewable Generation -- Part I: Dynamic Performance Analysis and Part II: Dynamic Cost  

SciTech Connect

Dynamic analysis of hybrid energy systems (HES) under flexible operation and variable renewable generation is considered in order to better understand various challenges and opportunities associated with the high system variability arising from the integration of renewable energy into the power grid. Unique consequences are addressed by devising advanced HES solutions in which multiple forms of energy commodities, such as electricity and chemical products, may be exchanged. Dynamic models of various unit operations are developed and integrated within two different HES options. One HES option, termed traditional, produces electricity only and consists of a primary heat generator (PHG) (e.g., a small modular reactor), a steam turbine generator, a wind farm, and a battery storage. The other HES option, termed advanced, includes not only the components present in the traditional option but also a chemical plant complex to repurpose excess energy for non-electricity services, such as for the production of chemical goods (e.g., transportation fuel). In either case, a given HES is connected to the power grid at a point of common coupling and requested to deliver a certain electricity generation profile as dictated by a regional power grid operator based on a predicted demand curve. Dynamic analysis of these highly-coupled HES are performed to identify their key dynamical properties and limitations and to prescribe solutions for best managing and mitigating the high variability introduced from incorporating renewable energy into the energy mix. A comparative dynamic cost analysis is also conducted to determine best HES options. The cost function includes a set of metrics for computing fixed costs, such as fixed operations and maintenance (O&M) and overnight capital costs, and also variable operational costs, such as cost of variability, variable O&M cost, and cost of environmental impact, together with revenues. Assuming different options for implementing PHG (e.g., natural gas, coal, nuclear), preliminary results identify the level of renewable penetration at which a given advanced HES option (e.g., a nuclear hybrid) becomes increasingly more economical than a traditional electricity-only generation solution. Conditions are also revealed under which carbon resources may be better utilized as carbon sources for chemical production rather than as combustion material for electricity generation.

Humberto E. Garcia; Amit Mohanty; Wen-Chiao Lin; Robert S. Cherry

2013-04-01T23:59:59.000Z

231

Laser Ablation Sampling of Materials Directly into the Formed Liquid Microjunction of a Continuous Flow Surface Sampling Probe/Electrospray Ionization Emitter for Mass Spectral Analysis and Imaging  

SciTech Connect

Transmission geometry laser ablation directly into a formed liquid microjunction of a continuous flow liquid microjunction surface sampling probe/electrospray ionization emitter was utilized for molecular and elemental detection and mass spectrometry imaging. The ability to efficiently capture and ionize ablated material was demonstrated by the detection of various small soluble n-mers of polyaniline and silver ion solvent clusters formed from laser ablation of electropolymerized polyaniline and silver thin films, respectively. In addition, analysis of surfaces that contain soluble components was accomplished by coating or laminating the sample with an insoluble film to enable liquid junction formation without directly extracting material from the surface. The ability to perform mass spectrometry imaging at a spatial resolution of about 50 m was illustrated by using laminated inked patterns on a microscope slide. In general, these data demonstrate at least an order of magnitude signal enhancement compared to the non-contact, laser ablation droplet capture-based surface sampling/ionization approaches that have been previously presented.

Ovchinnikova, Olga S [ORNL] [ORNL; Lorenz, Matthias [ORNL] [ORNL; Kertesz, Vilmos [ORNL] [ORNL; Van Berkel, Gary J [ORNL] [ORNL

2013-01-01T23:59:59.000Z

232

Long-term Analysis of Gear Loads in Fixed Offshore Wind Turbines Considering Ultimate Operational Loadings  

Science Journals Connector (OSTI)

Abstract The long-term extreme value analysis of gear transmitted load due to the main shaft torque is presented. Two methods, the multibody simulations (MBS) and a simplified method, are demonstrated for the gear transmitted load calculation. The simplified method is verified by the MBS results. The long-term extreme value of the gear transmitted load for wind speeds from the cut-in to the cut-out values is calculated by the simplified method from the long-term distribution of the main shaft torque. Three statistical methods for long-term extreme value analysis of the main shaft torque in the offshore wind turbines are presented. They are then used to predict the extreme value of the gear transmitted load. An alternative approach, the design state or the environmental contour method is proposed and verified by the full long-term results. The methods are exemplified by a 5 MW gearbox case study. The results of this paper are the basis for further work in Ultimate Limit State (ULS) gear design.

Amir R. Nejad; Zhen Gao; Torgeir Moan

2013-01-01T23:59:59.000Z

233

Analysis of radiation exposure for naval units of Operation CROSSROADS. Volume 1. Basic report. Technical report  

SciTech Connect

External radiation doses are reconstructed for crews of support and target ships of Joint Task Force One at Operation CROSSROADS, 1946. Volume I describes the reconstruction methodology, which consists of modeling the radiation environment, to include the radioactivity of lagoon water, target ships, and support ship contamination; retracing ship paths through this environment; and calculating the doses to shipboard personnel. The USS RECLAIMER, a support ship, is selected as a representative ship to demonstrate this methodology. Doses for all other ships are summarized. Volume II (Appendix A) details the results for target ship personnel. Volume III (Appendix B) details the results for support ship personnel. Calculated doses for more than 36,000 personnel aboard support ships while at Bikini range from zero to 1.7 rem. Of those approximately 34,000 are less than 0.5 rem. From the models provided, doses due to target ship reboarding and doses accrued after departure from Bikini can be calculated, based on the individual circumstances of exposure.

Weitz, R.; Thomas, C.; Klemm, J.; Stuart, J.; Knowles, M.

1982-03-03T23:59:59.000Z

234

ADVANTG Shielding Analysis for Closure Operations in an Open-Mode Repository  

SciTech Connect

en-mode repository concepts could require worker entry into access drifts after placement of fuel casks in order to perform activities related to backfill, plug emplacement, routine maintenance, or performance confirmation. An ideal emplacement-drift shielding configuration would minimize dose to workers while maximizing airflow through the emplacement drifts. This paper presents a preliminary investigation of the feasibility and effectiveness of radiation shielding concepts that could be employed to facilitate worker operations in an open-mode repository. The repository model for this study includes pressurized-water reactor fuel assemblies (60 GWd/MTU burnup, 40 year post-irradiation cooldown) in packages of 32 assemblies. The closest fuel packages are 5 meters from dosimetry voxels in the access drift. The unshielded dose to workers in the access drift is 73.7 rem/hour. Prior work suggests that open-mode repository concepts similar to this one would require 15 m3/s of ventilation airflow. Shielding concepts considered here include partial concrete plugs, labyrinthine shields, and stainless steel photon attenuator grids. Maximum dose to workers in the access drift was estimated for each shielding concept using MCNP5 with variance reduction parameters generated by ADVANTG. Because airflow through the shielding is important for open-mode repositories, a semi-empirical estimate of the head loss due to each shielding configuration was also calculated. Airflow and shielding performance vary widely among the proposed shielding configurations. Although the partial plug configuration had the best airflow performance, it allowed dose rates 1500 greater than the specified target. Labyrinthine shielding concepts yield doses on the order of 1 mrem/hour with configurations that impose 3 to 11 J/kg head loss. Adding 1 cm lead lining to the airflow channels of labyrinthine designs further reduces the worker dose by 65% to 95%. Photon-attenuator concepts may reduce worker dose to as low as 29 mrem/hour with head loss on the order of 1.9 J/kg.

Bevill, Aaron M [ORNL] [ORNL; Radulescu, Georgeta [ORNL] [ORNL; Scaglione, John M [ORNL] [ORNL; Howard, Rob L [ORNL] [ORNL

2013-01-01T23:59:59.000Z

235

Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit-1: Analysis of core damage frequency from internal events during mid-loop operations. Appendix I, Volume 2, Part 5  

SciTech Connect

Traditionally, probabilistic risk assessments (PRA) of severe accidents in nuclear power plants have considered initiating events potentially occurring only during full power operation. Some previous screening analyses that were performed for other modes of operation suggested that risks during those modes were small relative to full power operation. However, more recent studies and operational experience have implied that accidents during low power and shutdown could be significant contributors to risk. During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Lab. (BNL) and Sandia National Labs. (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this volume of the report is to document the approach utilized in the level-1 internal events PRA for the Surry plant, and discuss the results obtained. A phased approach was used in the level-1 program. In phase 1, which was completed in Fall 1991, a coarse screening analysis examining accidents initiated by internal events (including internal fire and flood) was performed for all plant operational states (POSs). The objective of the phase 1 study was to identify potential vulnerable plant configurations, to characterize (on a high, medium, or low basis) the potential core damage accident scenarios, and to provide a foundation for a detailed phase 2 analysis.

Chu, T.L.; Musicki, Z.; Kohut, P.; Yang, J.; Bozoki, G.; Hsu, C.J.; Diamond, D.J. [Brookhaven National Lab., Upton, NY (United States); Bley, D.; Johnson, D. [PLG Inc., Newport Beach, CA (United States); Holmes, B. [AEA Technology, Dorset (United Kingdom)] [and others

1994-06-01T23:59:59.000Z

236

Assessing the Impacts of Reduced Noise Operations of Wind Turbines on Neighbor Annoyance: A Preliminary Analysis in Vinalhaven, Maine  

E-Print Network (OSTI)

of Reduced Noise Operations of Wind Turbines on Neighborof Reduced Noise Operations of Wind Turbines on NeighborWind Speed (m/s) 3 Turbines (in operation at the time) Noise

Hoen, Ben

2010-01-01T23:59:59.000Z

237

Regulatory analysis for amendments to regulations for the environmental review for renewal of nuclear power plant operating licenses. Final report  

SciTech Connect

This regulatory analysis provides the supporting information for a proposed rule that will amend the Nuclear Regulatory Commission`s environmental review requirements for applications for renewal of nuclear power plant operating licenses. The objective of the proposed rulemaking is to improve regulatory efficiency by providing for the generic evaluation of certain environmental impacts associated with nuclear plant license renewal. After considering various options, the staff identified and analyzed two major alternatives. With Alternative A, the existing regulations would not be amended. This option requires that environmental reviews be performed under the existing regulations. Alternative B is to assess, on a generic basis, the environmental impacts of renewing the operating license of individual nuclear power plants, and define the issues that will need to be further analyzed on a case-by-case basis. In addition, Alternative B removes from NRC`s review certain economics-related issues. The findings of this assessment are to be codified in 10 CFR 51. The staff has selected Alternative B as the preferred alternative.

NONE

1996-05-01T23:59:59.000Z

238

Bohmian Mechanics with Discrete Operators  

E-Print Network (OSTI)

A deterministic Bohmian mechanics for operators with continuous and discrete spectra is presented. Randomness enters only through initial conditions. Operators with discrete spectra are incorporated into Bohmian mechanics by associating with each operator a continuous variable in which a finite range of the continuous variable correspond to the same discrete eigenvalue. In this way Bohmian mechanics can handle the creation and annihilation of particles. Examples are given and generalizations are discussed.

R. A. Hyman; Shane A. Caldwell; Edward Dalton

2004-01-02T23:59:59.000Z

239

Continuous-wave, pair-pumped laser  

SciTech Connect

We report room-temperature operation of what we believe is the first continuous-wave laser that relies exclusively on cooperative upconversion by coupled ion pairs to achieve population inversion.

Xie, P.; Rand, S.C. (Department of Electrical Engineering and Computer Science, University of Michigan, 1301 Beal Avenue, Ann Arbor, MI (USA))

1990-08-01T23:59:59.000Z

240

Notice of Availability of the Draft Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory, Los Alamos, NM (DOE/EIS-0380D) (07/07/06)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

638 Federal Register 638 Federal Register / Vol. 71, No. 130 / Friday, July 7, 2006 / Notices 1 Northern Natural Gas Company, 115 FERC ¶ 61,254 (2006). 1 Pinnacle West Capital Corp., 115 FERC ¶ 61,292 (2006). DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. RP06-332-000] Northern Natural Gas Company; Notice of Technical Conference June 28, 2006. The Federal Energy Regulatory Commission will convene a technical conference regarding Northern Natural Gas Company's proposal to adjust the boundary of its Operational Zones ABC and EF to the Iowa/Minnesota border in order to provide that delivery points in northern Iowa currently located in Operational Zone EF be moved to Operational Zone ABC, and delivery points in southwestern Minnesota currently located in Operational Zone

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Power system operation risk analysis considering charging load self-management of plug-in hybrid electric vehicles  

Science Journals Connector (OSTI)

Abstract Many jurisdictions around the world are supporting the adoption of electric vehicles through incentives and the deployment of a charging infrastructure to reduce greenhouse gas emissions. Plug-in hybrid electric vehicles (PHEVs), with offer mature technology and stable performance, are expected to gain an increasingly larger share of the consumer market. The aggregated effect on power grid due to large-scale penetration of \\{PHEVs\\} needs to be analyzed. Nighttime-charging which typically characterizes \\{PHEVs\\} is helpful in filling the nocturnal load valley, but random charging of large PHEV fleets at night may result in new load peaks and valleys. Active response strategy is a potentially effective solution to mitigate the additional risks brought by the integration of PHEVs. This paper proposes a power system operation risk analysis framework in which charging load self-management is used to control system operation risk. We describe an interactive mechanism between the system and \\{PHEVs\\} in conjunction with a smart charging model is to simulate the time series power consumption of PHEVs. The charging load is managed with adjusting the state transition boundaries and without violating the users’ desired charging constraints. The load curtailment caused by voltage or power flow violation after outages is determined by controlling charging power. At the same time, the system risk is maintained under an acceptable level through charging load self-management. The proposed method is implemented using the Roy Billinton Test System (RBTS) and several PHEV penetration levels are examined. The results show that charging load self-management can effectively balance the extra risk introduced by integration of \\{PHEVs\\} during the charging horizon.

Zhe Liu; Dan Wang; Hongjie Jia; Ned Djilali

2014-01-01T23:59:59.000Z

242

Microsoft Word - supplement Analysis SWEIS82302.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

38SA2 38SA2 Supplement Analysis Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory Modification of Management Methods for Transuranic Waste Characterization at Los Alamos National Laboratory August 13, 2002 Department of Energy National Nuclear Security Administration Los Alamos Site Office Supplement Analysis for the SWEIS Page 1 August 13, 2002 Introduction This Supplement Analysis (SA) has been prepared to determine if the Site-Wide Environmental Impact Statement for Continued Operations of Los Alamos National Laboratory (SWEIS) (DOE/EIS-0238) adequately addresses the environmental effects of a waste management proposal for installing and operating modular units for the

243

Assessing the Impacts of Reduced Noise Operations of Wind Turbines on Neighbor Annoyance: A Preliminary Analysis in Vinalhaven, Maine  

E-Print Network (OSTI)

only self-reported wind and turbine sound levels were used.Noise Operations of Wind Turbines on Neighbor Annoyance: ANoise Operations of Wind Turbines on Neighbor Annoyance: A

Hoen, Ben

2010-01-01T23:59:59.000Z

244

Continuity Program | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Continuity Program | National Nuclear Security Administration Continuity Program | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Continuity Program Home > About Us > Our Programs > Emergency Response > Continuity Program Continuity Program NNSA develops and implements the policy of the United States to maintain a comprehensive and effective continuity capability composed of an

245

Confirmatory Sampling and Analysis Plan for the Lower East Fork Poplar Creek operable unit, Oak Ridge, Tennessee  

SciTech Connect

On December 21, 1989, the EPA placed the US Department of Energy`s (DOE`s) Oak Ridge Reservation (ORR) on the National Priorities List (NPL). On January 1, 1992, a Federal Facilities Agreement (FFA) between the DOE Field Office in Oak Ridge (DOE-OR), EPA Region IV, and the Tennessee Department of Environment and Conservation (TDEC) went into effect. This FFA establishes the procedural framework and schedule by which DOE-OR will develop, coordinate, implement and monitor environmental restoration activities on the ORR in accordance with applicable federal and state environmental regulations. The DOE-OR Environmental Restoration Program for the ORR addresses the remediation of areas both within and outside the ORR boundaries. This sampling and analysis plan focuses on confirming the cleanup of the stretch of EFPC flowing from Lake Reality at the Y-12 Plant through the City of Oak Ridge, to Poplar Creek on the ORR and its associated floodplain. Both EFPC and its floodplain have been contaminated by releases from the Y-12 Plant since the mid-1950s. Because the EFPC site-designated as an ORR operable unit (OU) under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) is included on the NPL, its remediation must follow the specific procedures mandated by CERCLA, as amended by the Superfund Amendments and Reauthorization Act in 1986.

NONE

1996-04-01T23:59:59.000Z

246

Federal Energy Management Program: Continuous Change Institutional Change  

NLE Websites -- All DOE Office Websites (Extended Search)

Continuous Change Continuous Change Institutional Change Principle to someone by E-mail Share Federal Energy Management Program: Continuous Change Institutional Change Principle on Facebook Tweet about Federal Energy Management Program: Continuous Change Institutional Change Principle on Twitter Bookmark Federal Energy Management Program: Continuous Change Institutional Change Principle on Google Bookmark Federal Energy Management Program: Continuous Change Institutional Change Principle on Delicious Rank Federal Energy Management Program: Continuous Change Institutional Change Principle on Digg Find More places to share Federal Energy Management Program: Continuous Change Institutional Change Principle on AddThis.com... Sustainable Buildings & Campuses Operations & Maintenance

247

Exergy Analysis and Operational Efficiency of a Horizontal Ground Source Heat Pump System Operated in a Low-Energy Test House under Simulated Occupancy Conditions  

SciTech Connect

This paper presents data, analyses, measures of performance, and conclusions for a ground-source heat pump (GSHP) providing space conditioning to a 345m2 house whose envelope is made of structural insulated panels (SIP). The entire thermal load of this SIP house with RSI-3.7 (RUS-21) walls, triple pane windows with a U-factor of 1.64 W/m2 K (0.29 Btu/h ft2 oF) and solar heat gain coefficient (SHGC) of 0.25, a roof assembly with overall thermal resistance of about RSI-8.8 (RUS-50) and low leakage rates of 0.74 ACH at 50Pa was satisfied with a 2.16-Ton (7.56 kW) GSHP unit consuming negligible (9.83kWh) auxiliary heat during peak winter season. The highest and lowest heating COP achieved was 4.90 (October) and 3.44 (February), respectively. The highest and lowest cooling COP achieved was 6.09 (April) and 3.88 (August). These COPs are calculated on the basis of the total power input (including duct, ground loop, and control power losses ). The second Law (Exergy) analysis provides deep insight into how systemic inefficiencies are distributed among the various GSHP components. Opportunities for design and further performance improvements are identified. Through Exergy analysis we provide a true measure of how closely actual performance approaches the ideal, and it unequivocally identifies, better than energy analysis does, the sources and causes of lost work, the root cause of system inefficiencies.

Ally, Moonis Raza [ORNL; Baxter, Van D [ORNL; Munk, Jeffrey D [ORNL; Gehl, Anthony C [ORNL

2012-01-01T23:59:59.000Z

248

EIS-0426: Site-Wide Environmental Impact Statement for Continued...  

Office of Environmental Management (EM)

Site-Wide Environmental Impact Statement for Continued Operation of the Department of Energy National Nuclear Security Administration Nevada National Security Site and Off-Site...

249

Atomizing, continuous, water monitoring module  

DOE Patents (OSTI)

A system for continuously analyzing volatile constituents of a liquid is described. The system contains a pump for continuously pumping the liquid to be tested at a predetermined flow rate into an extracting container through a liquid directing tube having an orifice at one end and positioned to direct the liquid into the extracting container at a flow rate sufficient to atomize the liquid within the extracting container. A continuous supply of helium carrier gas at a predetermined flow rate is directed through a tube into the extracting container and co-mingled with the atomized liquid to extract the volatile constituents contained within the atomized liquid. The helium containing the extracted volatile constituents flows out of the extracting container into a mass spectrometer for an analysis of the volatile constituents of the liquid. 3 figs.

Thompson, C.V.; Wise, M.B.

1997-07-08T23:59:59.000Z

250

Sandia National Laboratories: Third Annual Continuous Reliability...  

NLE Websites -- All DOE Office Websites (Extended Search)

analysis of U.S. wind fleet performance based on aggregated fleet reliability data and includes operational statistics, availability time accounting, and top contributors...

251

EPA Notice of Availability of the Site-wide Continued Operation of Lawrence Livermore National Laboratory and Stockpile Stewardship and Management, Implementation (DOE/EIS-0348/DOE/EIS-0236-S3)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

08 08 Federal Register / Vol. 70, No. 82 / Friday, April 29, 2005 / Notices beneficial uses of dredged materials (i.e., wetlands restoration in Dorchester County, MD). EPA expressed environmental concerns over the remaining three alternatives (i.e., the proposed multiple new Confined Disposal Facilities in the Patapsco River, the Poplar Island Environmental Restoration Project expansion and the Large Island Restoration Middle Bay). EPA recommended that continued use of Open Water Placement in Virginia include the already designated NorfolkOcean Disposal Site given its available capacity. Rating EC1 EIS No. 20050053, ERP No. D-CGD- E03013-00, Compass Port and Deepwater Port License Application, To Construct a Liquefied Natural Gas (LNG) Receiving, Storage and

252

Guide to good practices for continuing training  

SciTech Connect

The purpose of this Guide to Good Practices for Continuing Training is to provide contractor training organizations with information and methods useful in the development and implementation of a continuing training program. DOE Order 5480.18A, ``Accreditation of Performance-Based Training for Category A Reactors and Nuclear Facilities,`` and DOE Order 5480.20, ``Personnel Selection, Qualification and Training Requirements at DOE Reactor and Non-reactor Nuclear Facilities`` Chapter 1, Paragraph 7, require each facility to design and implement a continuing training program. Continuing training is necessary to ensure that facility personnel continually improve their ability to operate and maintain their facility in a safe and reliable manner. Continuing training also should enhance the professionalism of these individuals and should make them aware of the possible consequences of misoperation.

Not Available

1993-02-01T23:59:59.000Z

253

Thermodynamics with Continuous Information Flow  

Science Journals Connector (OSTI)

We provide a unified thermodynamic formalism describing information transfers in autonomous as well as nonautonomous systems described by stochastic thermodynamics. We demonstrate how information is continuously generated in an auxiliary system and then transferred to a relevant system that can utilize it to fuel otherwise impossible processes. Indeed, while the joint system satisfies the second law, the entropy balance for the relevant system is modified by an information term related to the mutual information rate between the two systems. We show that many important results previously derived for nonautonomous Maxwell demons can be recovered from our formalism and use a cycle decomposition to analyze the continuous information flow in autonomous systems operating at a steady state. A model system is used to illustrate our findings.

Jordan M. Horowitz and Massimiliano Esposito

2014-07-28T23:59:59.000Z

254

APPROVAL TO CONTINUE SPONSORSHIP OF  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Competition Competition APPROVAL TO CONTINUE SPONSORSHIP OF THE_[insert the name of the laboratory/site/facility]___ AS A FEDERALLY FUNDED RESEARCH AND DEVELOPMENT CENTER The _[insert the name of the laboratory/site/facility]_ is a Department of Energy (DOE) Federally Funded Research and Development Center (FFRDC) managed and operated by _[insert the name of the contractor]_ under DOE Contract _[insert contract number]_. The current contract, which serves as the sponsoring agreement, expires [insert date]. _[insert one or two sentences briefly describing the laboratory/site/facility mission]_. Federal Acquisition Regulation (FAR) 35.017-4 provides for the Head of the sponsoring Agency to approve the continuance of the sponsorship of the FFRDC.

255

Fractions continues Michel Waldschmidt  

E-Print Network (OSTI)

´erentes oeuvres d'art, 2 appara^it aussi dans des oeuvres artistiques persanes. 2 #12;Figure 1. Fraction continue

Waldschmidt, Michel

256

Operations Information  

NLE Websites -- All DOE Office Websites (Extended Search)

Standards BPA Operations Information (OPI) Transmission Services operates and plans for regional and national system needs. Transmission Services coordinates system operation and...

257

Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1. Volume 5: Analysis of core damage frequency from seismic events during mid-loop operations  

SciTech Connect

In 1989 the US Nuclear Regulatory Commission (NRC) initiated an extensive program to examine carefully the potential risks during low-power and shutdown operations. The program included two parallel projects, one at Brookhaven National Laboratory studying a pressurized water reactor (Surry Unit 1) and the other at Sandia National Laboratories studying a boiling water reactor (Grand Gulf). Both the Brookhaven and Sandia projects have examined only accidents initiated by internal plant faults--so-called ``internal initiators.`` This project, which has explored the likelihood of seismic-initiated core damage accidents during refueling shutdown conditions, is complementary to the internal-initiator analyses at Brookhaven and Sandia. This report covers the seismic analysis at Surry Unit 1. All of the many systems modeling assumptions, component non-seismic failure rates, and human error rates that were used in the internal-initiator study at Surry have been adopted here, so that the results of the two studies can be as comparable as possible. Both the Brookhaven study and this study examine only two shutdown plant operating states (POSs) during refueling outages at Surry, called POS 6 and POS 10, which represent mid-loop operation before and after refueling, respectively. This analysis has been limited to work analogous to a level-1 seismic PRA, in which estimates have been developed for the core-damage frequency from seismic events during POSs 6 and 10. The results of the analysis are that the core-damage frequency of earthquake-initiated accidents during refueling outages in POS 6 and POS 10 is found to be low in absolute terms, less than 10{sup {minus}6}/year.

Budnitz, R.J. [Future Resources Associates, Inc., Berkeley, CA (United States); Davis, P.R. [PRD Consulting (United States); Ravindra, M.K.; Tong, W.H. [EQE International, Inc., Irvine, CA (United States)

1994-08-01T23:59:59.000Z

258

Equipment Operational Requirements  

SciTech Connect

The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

2009-06-11T23:59:59.000Z

259

Engineering Design, Construction, Operation and Analysis of the 2007 Texas A&M University Solar Decathlon House  

E-Print Network (OSTI)

This report presents the design, construction, and operation of a 100% solar-powered house from an engineering perspective. This includes energy simulation results, selection of systems, design of systems, assembly of systems, integration between...

Ramirez, E. J.

260

Engineering Design, Construction, Operation and Analysis of the 2007 Texas A&M University Solar Decathlon House  

E-Print Network (OSTI)

This report presents the design, construction, and operation of a 100% solar-powered house from an engineering perspective. This includes energy simulation results, selection of systems, design of systems, assembly of systems, integration between...

Ramirez, Eduardo

2008-06-10T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

An Analysis of the health impacts from PM and NOx emissions resulting from train operations in the Alameda Corridor, CA  

E-Print Network (OSTI)

2009). Estimating PM and NOx Train Emissions in the AlamedaAuthority. Number of Trains Running on the Alameda Corridor.x emissions resulting from train operations in the Alameda

Sangkapichai, Mana; Saphores, Jean-Daniel M; Ogunseitan, Oladele; Ritchie, Stephen G.; You, Soyoung Iris; Lee, Gunwoo

2010-01-01T23:59:59.000Z

262

Nickel-based superalloy operating temperature determination via analysis of gamma/gamma' microstructure and coating/base material interdiffusion  

E-Print Network (OSTI)

The average operating temperature of RENÉ N5® high pressure turbine blades was evaluated via [gamma]/[gamma]' microstructure and coating/base metal interdiffusion methods. The [gamma]' volume fraction was measured by point ...

Ham, Wendy D. (Wendy Decker)

2005-01-01T23:59:59.000Z

263

Ensemble Kalman Filter and 4D-Var Intercomparison with the Japanese Operational Global Analysis and Prediction System  

Science Journals Connector (OSTI)

The local ensemble transform Kalman filter (LETKF) is implemented and assessed with the experimental operational system at the Japanese Meteorological Agency (JMA). This paper describes the details of the LETKF system and verification of ...

Takemasa Miyoshi; Yoshiaki Sato; Takashi Kadowaki

2010-07-01T23:59:59.000Z

264

OESYS : a simulation tool for non-conventional energy applications analysis : theoretical and operational description with user documentation  

E-Print Network (OSTI)

A method is developed for assessing both the operational and economic performance of variable mixes of energy conversion technologies within their specific service environments. This method is incorporated into OESYS ...

Dinwoodie, Thomas L.

1980-01-01T23:59:59.000Z

265

Travinfo Evaluation (technology Element) Traveler Information Center (tic) Study: Operator Interface Component-phase Iv: Institutional Analysis  

E-Print Network (OSTI)

Objective: a. Looking back on TIC operations from the timestart of your tenure at the TIC), what do you feel are theorganization such as the TIC? b. Do you have any remaining

Miller, Mark; Loukakos, Dimitri

1998-01-01T23:59:59.000Z

266

A Robust Four-Fluid Transient Flow Simulator as an Analysis and Decision Making Tool for Dynamic Kill Operation  

E-Print Network (OSTI)

The worst scenario of drilling operation is blowout which is uncontrolled flow of formation fluid into the wellbore. Blowouts result in environmental damage with potential risk of injuries and fatalities. Although not all blowouts result in disaster...

Haghshenas, Arash

2013-04-24T23:59:59.000Z

267

Performance analysis of supply and return fans for HVAC systems under different operating strategies of economizer dampers  

Science Journals Connector (OSTI)

HVAC systems and associated equipment consume a relatively large fraction of total building energy consumption, a significant portion of which is attributed to fan operation. The operation of economizer dampers when installed can cause high energy consumption in fans if they are not functioning in proper and optimal manner. This will mainly be due to the potential high pressure drops through those dampers and associated high total pressures that should be developed by supply and/or return fans. It is then necessary to ensure that a proper strategy to operate optimally the economizer dampers is implemented with minimum fan energy use. The paper examines several operation strategies of the economizer dampers and investigates their effects on the performance of both the supply and return fans in HVAC system. It also discusses a new operating strategy for economizer dampers that can lead to lower fan energy use. The strategies are evaluated by simulations for a typically existing HVAC system. Several factors such as the building locations, system characteristics, resistance in the duct where the dampers are installed, supply air temperature and economizer control, and minimum ventilation requirements are also considered during the evaluations. The results show that the way of the economizer dampers been controlled has a significant effect on fan performance and its energy use. The proposed strategy if properly implemented can provide fan energy saving in the range of 5–30%, depending mainly on the number of hours when the system operates in the free cooling mode, damper characteristics, and minimum outdoor air.

Nabil Nassif

2010-01-01T23:59:59.000Z

268

Cleaning Up the Hanford River Corridor and Improving Site Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

operations * Continue River Corridor cleanup, including remediation of 618-10 Burial Ground * Continue Plutonium Finishing Plant deactivation, decommissioning and demolition *...

269

Rankine cycle leak detection via continuous monitoring  

SciTech Connect

Rankine cycle power plants operate on a closed cycle in which heat is transferred from a high temperature reservoir to a low temperature sink while performing useful work. leaks in this cycle cause the loss of working fluid and/or corrosion of the power plant. Both of these constitute a loss of capital assets. A severe leak can reduce the efficiency of the cycle to the extent of creating an operating loss. PNL is undertaking the development of continuous monitoring techniques to protect rankine cycle plants from such losses. The location of these continuous monitors on an organic rankine cycle is described and shown schematically.

Kindle, Cecil H.

1982-10-08T23:59:59.000Z

270

Pantex continues community outreach | National Nuclear Security  

National Nuclear Security Administration (NNSA)

continues community outreach | National Nuclear Security continues community outreach | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex continues community outreach Pantex continues community outreach Posted By Office of Public Affairs Pantexans showed their community spirit last week when employees, along with their families and friends, volunteered their time at two local

271

An analysis of processing methods and a comparison of operational efficiencies in ten Texas broiler processing plants  

E-Print Network (OSTI)

of labor utilisation in either small dressing plants or in large commercial plants. Hurst (1946) made a study of 13 farmer cooperatives in the eastern' midwestern and southern states ~ He follnd that 23i2 broilers were processed per man houri From his... operations oou14 increase the average farm output from 10, 000 to 20~000 ducks per year. smacker and Scanlan (1950) studie4 the operation of 48 I'arm and small commercial processing plants in the north- eastern states. Their findings Indicate...

Gardner, Frederick Albert

2012-06-07T23:59:59.000Z

272

Continuous sulfur removal process  

DOE Patents (OSTI)

A continuous process for the removal of hydrogen sulfide from a gas stream using a membrane comprising a metal oxide deposited on a porous support is disclosed. 4 figures.

Jalan, V.; Ryu, J.

1994-04-26T23:59:59.000Z

273

2011 Annual Workforce Analysis and Staffing Plan Report - Richland  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Richland Richland Operations Office 2011 Annual Workforce Analysis and Staffing Plan Report - Richland Operations Office Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Individual site summaries developed at the end of each year are a basis for DOE Federal Technical Capability Panel reporting to the Secretary of Energy summarizing DOE's federal technical capabilities for defense nuclear facility safety assurance. 2011 Annual Workforce Analysis and Staffing Plan Report - RL

274

XSophe-Sophe-XeprView®. A computer simulation software suite (v. 1.1.3) for the analysis of continuous wave EPR spectra  

Science Journals Connector (OSTI)

The XSophe-Sophe-XeprView® computer simulation software suite enables scientists to easily determine spin Hamiltonian parameters from isotropic, randomly oriented and single crystal continuous wave electron paramagnetic resonance (CW EPR) spectra from radicals and isolated paramagnetic metal ion centers or clusters found in metalloproteins, chemical systems and materials science. \\{XSophe\\} provides an X-windows graphical user interface to the Sophe programme and allows: creation of multiple input files, local and remote execution of Sophe, the display of sophelog (output from Sophe) and input parameters/files. Sophe is a sophisticated computer simulation software programme employing a number of innovative technologies including; the Sydney \\{OPera\\} HousE (SOPHE) partition and interpolation schemes, a field segmentation algorithm, the mosaic misorientation linewidth model, parallelization and spectral optimisation. In conjunction with the SOPHE partition scheme and the field segmentation algorithm, the SOPHE interpolation scheme and the mosaic misorientation linewidth model greatly increase the speed of simulations for most spin systems. Employing brute force matrix diagonalization in the simulation of an EPR spectrum from a high spin Cr(III) complex with the spin Hamiltonian parameters ge=2.00, D=0.10 cm?1, E/D=0.25, Ax=120.0, Ay=120.0, Az=240.0×10?4 cm?1 requires a SOPHE grid size of N=400 (to produce a good signal to noise ratio) and takes 229.47 s. In contrast the use of either the SOPHE interpolation scheme or the mosaic misorientation linewidth model requires a SOPHE grid size of only N=18 and takes 44.08 and 0.79 s, respectively. Results from Sophe are transferred via the Common Object Request Broker Architecture (CORBA) to \\{XSophe\\} and subsequently to XeprView® where the simulated CW EPR spectra (1D and 2D) can be compared to the experimental spectra. Energy level diagrams, transition roadmaps and transition surfaces aid the interpretation of complicated randomly oriented CW EPR spectra and can be viewed with a web browser and an OpenInventor scene graph viewer.

Graeme R. Hanson; Kevin E. Gates; Christopher J. Noble; Mark Griffin; Anthony Mitchell; Simon Benson

2004-01-01T23:59:59.000Z

275

The physical and chemical state of Westinghouse Phosphoric Acid Fuel Cell assemblies after long term operation: Surface and near-surface analysis  

SciTech Connect

An attempt was made to correlate performance losses with materials compatibility and compositional changes in Phosphoric Acid Fuel Cell (PAFC) electrode assemblies as a function of operation time. Westinghouse PAFC stacks were run under a constant operating regime and portions of some of the single cells were analysed after stack operation for 5000 hrs and for 16,000 hrs along with appropriate reference samples. The PAFC assemblies were disassembled, sectioned where appropriate and analyzed using scanning and transmission electron microscopy (SEM and TEM), Rutherford backscattering spectroscopy (RBS), electron microprobe analysis (EMP), and x-ray photoelectron spectroscopy (XPS). The profiles of the Pt catalyst in both the anode and the cathode layer did not show any preferential loss or peaking. The most pronounced change in cell composition detected following stack operation for 5000 and for 16,000 hours was the increase in Pt/C ratio, that was related to loss of carbon from the cathode electrocatalyst. In contrast, the anode catalyst layer maintains the same ratio of Pt/C following 16,000 hours of operation. The loss of carbon is thought to occur by an electrochemical mechanism and is enhanced at the higher potentials experienced by the air cathode in the fuel cell. In addition, TEM results clearly demonstrate the well recognized phenomenon of Pt particle agglomeration in the cathode catalyst layer, which is seen to be quite substantial after 5000 hours of stack operation. The mechanical integrity of the assemblies was found to be quite satisfactory after 5000 hours, but much less so after 16,000 hours. Questions regarding carbon and Pt corrosion, Pt migration, and the mechanical and physical integrity of the PAFC structures are addressed and are all postulated to be contributing to the observed cell performance losses. 10 refs., 17 figs.

Paffett, M.T.; Hutchinson, W.; Farr, J.D.; Papin, P.; Beery, J.G.; Gottesfeld, S. (Los Alamos National Lab., NM (USA)); Feret, J. (Westinghouse Electric Corp., Pittsburgh, PA (USA))

1990-01-01T23:59:59.000Z

276

Analysis of radiation exposure for Naval personnel at Operation Castle. Technical report, 1 January 1983-31 January 1984  

SciTech Connect

Film-badge doses are reconstructed for sixteen ships and the residence islands of Enewetak and Kwajalein Atolls resulting from the six nuclear detonations comprising Operation CASTLE (March-May 1954). Fallout from Shots BRAVO and ROMEO was the major source of contamination on most of the ships and islands. Varying amounts of fallout from Shots UNION, YANKEE, and NECTAR contributed somewhat to the total doses of the shipboard and island-based personnel; no fallout was experienced as a result of Shot KOON. Shipboard personnel received additional exposure from hulls and salt water piping systems that had become contaminated from operating in the radioactive waters of Bikini Lagoon. From the reconstructed radiation environments, both topside and below, an equivalent film badge dose is calculated and compared to actual dosimetry data. Agreement is very good during badged periods when the ships received significant fallout. When topside intensities were not documented, generally late in the operation when intensity levels were low, agreement is not as good. Calculated ship contamination doses of significance are in excellent agreement with limited available dosimetry data. Calculated average doses for shipboard personnel range from a low of 0.19 rem for the crew of the USS LST-825 to a high of 3.56 rem for the crew of the USS PHILIP. Average doses on the residence islands of Enewetak and Kwajalein Atolls are 1.09 rem and 0.32 rem, respectively.

Thomas, C.; Goetz, J.; Klemm, J.; Weitz, R.

1984-02-28T23:59:59.000Z

277

DOE Oak Ridge Operations managers  

NLE Websites -- All DOE Office Websites (Extended Search)

Oak Ridge Operations managers As the last few articles have shown, the period immediately following the end of World War II was one of constant and continuing change for Oak Ridge....

278

Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Analysis of core damage frequency from internal floods during mid-loop operations. Volume 4  

SciTech Connect

The major objective of the Surry internal flood analysis was to provide an improved understanding of the core damage scenarios arising from internal flood-related events. The mean core damage frequency of the Surry plant due to internal flood events during mid-loop operations is 4.8E-06 per year, and the 5th and 95th percentiles are 2.2E-07 and 1.8E-05 per year, respectively. Some limited sensitivity calculations were performed on three plant improvement options. The most significant result involves modifications of intake-level structure on the canal, which reduced core damage frequency contribution from floods in mid-loop by about 75%.

Kohut, P. [Brookhaven National Lab., Upton, NY (United States)

1994-07-01T23:59:59.000Z

279

TESTING AND PERFORMANCE ANALYSIS OF NASA 5 CM BY 5 CM BI-SUPPORTED SOLID OXIDE ELECTROLYSIS CELLS OPERATED IN BOTH FUEL CELL AND STEAM ELECTROLYSIS MODES  

SciTech Connect

A series of 5 cm by 5 cm bi-supported Solid Oxide Electrolysis Cells (SOEC) were produced by NASA for the Idaho National Laboratory (INL) and tested under the INL High Temperature Steam Electrolysis program. The results from the experimental demonstration of cell operation for both hydrogen production and operation as fuel cells is presented. An overview of the cell technology, test apparatus and performance analysis is also provided. The INL High Temperature Steam Electrolysis laboratory has developed significant test infrastructure in support of single cell and stack performance analyses. An overview of the single cell test apparatus is presented. The test data presented in this paper is representative of a first batch of NASA's prototypic 5 cm by 5 cm SOEC single cells. Clearly a significant relationship between the operational current density and cell degradation rate is evident. While the performance of these cells was lower than anticipated, in-house testing at NASA Glenn has yielded significantly higher performance and lower degradation rates with subsequent production batches of cells. Current post-test microstructure analyses of the cells tested at INL will be published in a future paper. Modification to cell compositions and cell reduction techniques will be altered in the next series of cells to be delivered to INL with the aim to decrease the cell degradation rate while allowing for higher operational current densities to be sustained. Results from the testing of new batches of single cells will be presented in a future paper.

R. C. O'Brien; J. E. O'Brien; C. M. Stoots; X. Zhang; S. C. Farmer; T. L. Cable; J. A. Setlock

2011-11-01T23:59:59.000Z

280

A Continuity Theorem for Stinespring's Dilation  

E-Print Network (OSTI)

We show a continuity theorem for Stinespring's dilation: two completely positive maps between arbitrary C*-algebras are close in cb-norm iff we can find corresponding dilations that are close in operator norm. The proof establishes the equivalence of the cb-norm distance and the Bures distance for completely positive maps. We briefly discuss applications to quantum information theory.

Kretschmann, Dennis; Werner, Reinhard F

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

DOE/EIS-0075-SA-02: Operational and Engineering Modifications and Regulatory Review Supplemental Analysis of Site-Specific and Programmatic Environmental Impact Statements (September 2009)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

SPR-EIS-0075-SA-02 SPR-EIS-0075-SA-02 SUPPLEMENT ANALYSIS OF SITE-SPECIFIC AND PROGRAMMATIC ENVIRONMENTAL IMPACT STATEMENTS: OPERATIONAL AND ENGINEERING MODIFICATIONS, AND REGULATORY REVIEW U.S. Department of Energy Strategic Petroleum Reserve 900 Commerce Road East New Orleans, Louisiana 70123 September 2009 DOE/SPR/EIS-0075-SA02 Page 3 of 51 Prepared for the U. S. Department of Energy Strategic Petroleum Reserve Project Management Office under Contract No. DE-AC96-03PO92207 DynMcDermott Petroleum Operations Company 850 South Clearview Parkway New Orleans, Louisiana 70123 Page 4 of 51 DOE/SPR/EIS-0075-SA02 Table of Contents I. Introduction .......................................................................................................... 6

282

Voluntary Protection Program Onsite Review, Livermore Operations- January 2012  

Energy.gov (U.S. Department of Energy (DOE))

Evaluation to determine whether the Livermore Operations is continuing to perform at a level deserving DOE-VPP Star recognition.

283

Voluntary Protection Program Onsite Review, Los Alamos Operations- November 2011  

Energy.gov (U.S. Department of Energy (DOE))

Evaluation to determine whether Los Alamos Operations is continuing to perform at a level deserving DOE-VPP Star recognition.

284

2012 Workforce Analysis and Staffing Plan Report Memo, Guidance and Template  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy Federal Technical Capability Order, DOE O 426.1, requires that managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards.

285

2014 Workforce Analysis and Staffing Plan Report Memo, Guidance and Template  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy Federal Technical Capability Order, DOE O 426.1, requires that managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards.

286

2013 Workforce Analysis and Staffing Plan Report Memo, Guidance and Template  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy Federal Technical Capability Order, DOE 0 426.1, requires that managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards.

287

Analysis of radiation exposure, Third Marine Corps Provisional Atomic Exercise Brigade. Exercise Desert Rock VI, Operation Teapot. Technical report  

SciTech Connect

The radiation dose is reconstructed for 3d MCPAEB personnel participating in exercises involving helicopter-lifted assaults in conjunction with Shot Bee of Operation Teapot, Exercise Desert Rock VI. Brigade personnel were exposed to initial radiation while in trenches at the time of the Shot Bee detonation. They were also exposed to residual radiation from an earlier test shot (Shot Turk) during their subsequent maneuvers and to residual radiation from Shot Bee during an inspection of equipment displays. The calculated total gamma doses to the bulk of the participating troops range from about 0.57-0.85 rem.

Goetz, J.; Klemm, J.; Ortlieb, E.

1984-02-15T23:59:59.000Z

288

EIS-0225-SA-05: Supplement Analysis Determination | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Analysis Determination Analysis Determination EIS-0225-SA-05: Supplement Analysis Determination Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapon Components DOE's NNSA Production Office Pantex has prepared a SA to determine whether the Final Environmental Impact Statement for the Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapon Components, also known as the Site-Wide Environmental Impact Statement, adequately addresses the environmental impacts of continued Pantex Plant operations, or if additional documentation under NEPA is needed. EIS-0225-SA-05-Determination-2013.pdf More Documents & Publications EIS-0225-SA-05: Supplement Analysis 2013 Annual Planning Summary for the NNSA Production Office EIS-0225-SA-03: Supplement Analysis

289

A Multi-Scale Analysis Scheme on Abelian Groups with an Application to Operators Dual to Hill's Equation  

E-Print Network (OSTI)

We present an abstract multiscale analysis scheme for matrix functions $(H_{\\varepsilon}(m,n))_{m,n\\in \\mathfrak{T}}$, where $\\mathfrak{T}$ is an Abelian group equipped with a distance $|\\cdot|$. This is an extension of the scheme developed by Damanik and Goldstein for the special case $\\mathfrak{T} = \\mathbb{Z}^\

David Damanik; Michael Goldstein; Milivoje Lukic

2014-09-28T23:59:59.000Z

290

JAPANESE REACTOR SAGA CONTINUES  

Science Journals Connector (OSTI)

NUCLEAR POWER: Japanese engineers fight to regain control; Congress reviews U.S. nuclear plant practices ... RADIATION CONCERNS continued to heighten last week at Japan’s Fukushima Daiichi Nuclear Power Station, which suffered catastrophic damage from the March 11 earthquake and tsunami. ...

JEFF JOHNSON

2011-04-04T23:59:59.000Z

291

Drilling continues upward momentum  

SciTech Connect

This paper discusses how the drilling recovery that began during the second half of 1989 is continuing into 1990. On top of this, the Iraqi invasion of Kuwait has caused disarray in oil markets, driving up oil prices, and disrupting access to oil supplies. Potentially, this upheaval could lead to an upward spike in worldwide drilling activity.

Moritis, G.

1990-09-24T23:59:59.000Z

292

DSM CONTINUES PORTFOLIO SHIFT  

Science Journals Connector (OSTI)

DSM CONTINUES PORTFOLIO SHIFT ... THE DUTCH specialty chemicals company DSM closed out 2010 with two transactions intended to sharpen its focus on the life and materials sciences. ... The announcements came just days after DSM signed an agreement to sell its elastomers business to Lanxess. ...

MICHAEL MCCOY

2011-01-03T23:59:59.000Z

293

2013 (COOP) Continuity of Operations Awareness Annual Training  

Energy.gov (U.S. Department of Energy (DOE))

Date: Must be completed by September 30, 2013.Time: Online (30-45 min)Registration link: DOE/NNSA employees can access OLC directly through ESS. Others need to use the OLC link

294

Analysis of operations and cyber security policies for a system of cooperating Flexible Alternating Current Transmission System (FACTS) devices.  

SciTech Connect

Flexible Alternating Current Transmission Systems (FACTS) devices are installed on electric power transmission lines to stabilize and regulate power flow. Power lines protected by FACTS devices can increase power flow and better respond to contingencies. The University of Missouri Rolla (UMR) is currently working on a multi-year project to examine the potential use of multiple FACTS devices distributed over a large power system region in a cooperative arrangement in which the FACTS devices work together to optimize and stabilize the regional power system. The report describes operational and security challenges that need to be addressed to employ FACTS devices in this way and recommends references, processes, technologies, and policies to address these challenges.

Phillips, Laurence R.; Tejani, Bankim; Margulies, Jonathan; Hills, Jason L.; Richardson, Bryan T.; Baca, Micheal J.; Weiland, Laura

2005-12-01T23:59:59.000Z

295

Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1. Volume 2, Part 1C: Analysis of core damage frequency from internal events for plant operational State 5 during a refueling outage, Main report (Sections 11--14)  

SciTech Connect

This document contains the accident sequence analysis of internally initiated events for Grand Gulf, Unit 1 as it operates in the Low Power and Shutdown Plant Operational State 5 during a refueling outage. The report documents the methodology used during the analysis, describes the results from the application of the methodology, and compares the results with the results from two full power analyses performed on Grand Gulf.

Whitehead, D. [Sandia National Labs., Albuquerque, NM (United States); Darby, J. [Science and Engineering Associates, Inc., Albuquerque, NM (United States); Yakle, J. [Science Applications International Corp., Albuquerque, NM (United States)] [and others

1994-06-01T23:59:59.000Z

296

The Countdown Continues INSIDE  

NLE Websites -- All DOE Office Websites (Extended Search)

1, 1996 1, 1996 Number 11 The Countdown Continues INSIDE 2 University Close-Up: Elmhurst College 4 DOE Reviews DZero Upgrade 5 Griffing Appointed ES&H Head 10 Laboratory Adopts More Efficient Payroll System Only a month remains before fixed-target experiments will resume at Fermilab. As the days dwindle down to a precious few, experi- menters and staff throughout the Laboratory scramble to get ready. The last issue of FermiNews reported on countdown activities for the Accelerator and Computing Divisions and the Facilities Engineering Services Section. For this issue the Research Division, the Physics Section and five of the 10 experiments f continued on page 6 Photo by Reidar Hahn described their down-to-the-wire preparations. "It's nip and tuck in terms of building the

297

Continuous Fiber Ceramic Composites  

SciTech Connect

Fiber-reinforced ceramic composites demonstrate the high-temperature stability of ceramics--with an increased fracture toughness resulting from the fiber reinforcement of the composite. The material optimization performed under the continuous fiber ceramic composites (CFCC) included a series of systematic optimizations. The overall goals were to define the processing window, to increase the robustinous of the process, to increase process yield while reducing costs, and to define the complexity of parts that could be fabricated.

None

2002-09-01T23:59:59.000Z

298

Towards a methodology for the systematic analysis and design of efficient chemical processes: Part 1. From unit operations to elementary process functions  

Science Journals Connector (OSTI)

A successful intensification of a chemical process requires a holistic view of the process and a systematic debottlenecking, which is obtained by identifying and eliminating the main transport resistances that limit the overall process performance and thus can be considered as rate determining steps on the process level. In this paper, we will suggest a new approach that is not based on the classical unit operation concept, but on the analysis of the basic functional principles that are encountered in chemical processes. A review on the history of chemical engineering in general and more specifically on the development of the unit operation concept underlines the outstanding significance of this concept in chemical and process engineering. The unit operation concept is strongly linked with the idea of thinking in terms of apparatuses, using technology off the shelf. The use of such “ready solutions” is of course convenient in the analysis and design of chemical processes; however, it can also be a problem since it inherently reduces the possibilities of process intensification measures. Therefore, we break with the tradition of thinking in terms of “unit apparatuses” and suggest a new, more rigorous function-based approach that focuses on the underlying fundamental physical and chemical processes and fluxes. For this purpose, we decompose the chemical process into so-called functional modules that fulfill specific tasks in the course of the process. The functional modules itself can be further decomposed and represented by a linear combination of elementary process functions. These are basis vectors in thermodynamic state space. Within this theoretical framework we can individually examine possible process routes and identify resistances in individual process steps. This allows us to analyze and propose possible options for the intensification of the considered chemical process.

Hannsjörg Freund; Kai Sundmacher

2008-01-01T23:59:59.000Z

299

EPR-Steering measure for two-mode continuous variable states  

E-Print Network (OSTI)

Steering is a manifestation of quantum correlations that embodies the Einstein-Podolsky-Rosen (EPR) paradox. While there have been recent attempts to quantify steering, continuous variable systems remained elusive. We introduce a steering measure for two-mode continuous variable systems that is valid for arbitrary states. The measure is based on the violation of an optimized variance test for the EPR paradox, and admits a computable and experimentally friendly lower bound only depending on the second moments of the state, which reduces to a recently proposed quantifier of steerability by Gaussian measurements. We further show that Gaussian states are extremal with respect to our measure, minimizing it among all continuous variable states with fixed second moments. As a byproduct of our analysis, we generalize and relate well-known EPR-steering criteria. Finally an operational interpretation is provided, as the proposed measure is shown to quantify the optimal guaranteed key rate in semi-device independent qua...

Kogias, Ioannis

2014-01-01T23:59:59.000Z

300

EPR-Steering measure for two-mode continuous variable states  

E-Print Network (OSTI)

Steering is a manifestation of quantum correlations that embodies the Einstein-Podolsky-Rosen (EPR) paradox. While there have been recent attempts to quantify steering, continuous variable systems remained elusive. We introduce a steering measure for two-mode continuous variable systems that is valid for arbitrary states. The measure is based on the violation of an optimized variance test for the EPR paradox, and admits a computable and experimentally friendly lower bound only depending on the second moments of the state, which reduces to a recently proposed quantifier of steerability by Gaussian measurements. We further show that Gaussian states are extremal with respect to our measure, minimizing it among all continuous variable states with fixed second moments. As a byproduct of our analysis, we generalize and relate well-known EPR-steering criteria. Finally an operational interpretation is provided, as the proposed measure is shown to quantify the optimal guaranteed key rate in semi-device independent quantum key distribution.

Ioannis Kogias; Gerardo Adesso

2014-11-03T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Preliminary experimental analysis of a small-scale prototype SWRO desalination plant, designed for continuous adjustment of its energy consumption to the widely varying power generated by a stand-alone wind turbine  

Science Journals Connector (OSTI)

Abstract Given the significant water-energy problems associated with many remote and arid areas of the planet, most studies, projects and developments of installations for the production of fresh water using desalination technologies powered by renewable energy sources have focussed on small-scale stand-alone systems. The most commonly used energy sources have been solar photovoltaic and wind and the most widely applied desalination technology that of reverse osmosis (RO). Most of the systems use batteries as a means of mass energy storage and the RO plants normally operate at constant pressure and flow rate. This paper presents a small-scale prototype SWRO (seawater reverse osmosis) desalination plant designed to continuously adapt its energy consumption to the variable power supplied by a wind turbine (WT), dispensing with mass energy storage in batteries and proposing the use of a supercapacitor bank as a dynamic regulation system. A description is given of the tests performed to date with the SWRO desalination plant connected to the conventional grid while controlling the number of pressure vessels that are connected/disconnected to/from the system and regulating their operating pressures and flow rates (within predetermined admissible limits) to maintain a constant permeate recovery rate and adapt the energy consumption of the plant to a widely varying simulated wind energy supply. One of the most important conclusions that can be drawn from the studies undertaken is the feasibility of adapting the consumption of the prototype of the SWRO desalination plant to widely varying WT-generated power. Despite using various time interval lengths in which it was assumed that the WT output power remained constant, a perfect fit was not obtained between the theoretical WT-generated power and the power consumed by the SWRO desalination plant, nor was it possible to maintain a constant permeate recovery rate at each instant.

José A. Carta; Jaime González; Pedro Cabrera; Vicente J. Subiela

2015-01-01T23:59:59.000Z

302

Ohio incinerator battle continues  

SciTech Connect

Waste Technologies Industries (WTI; East Liverpool, Ohio) is trying to wing what it hopes will be its final battle in a 13-year, $160 million war with the government, and community and environmental groups. The company since 1980 has sought EPA approval to operate a hazardous waste incinerator in East Liverpool, Ohio. WTI late last year conducted a pre-test burn, or shakedown, during which the incinerator burned certain types of hazardous waste. The test demonstrates the incinerator's performance under normal operating conditions, Regulatory authorities, including EPA and the Ohio Environmental Protection Agency (OEPA), monitored activity during the shakedown, which was limited to 720 hours of operation. In accordance with RCRA requirements, the company in March conducted a trial burn to demonstrate that the incinerator meets permit standards. WTI's permit specifies three performance parameters the incinerator must meet -- particulate and hydrogen chloride emissions limits, and destruction removal efficiencies (DREs).

Melody, M.

1993-05-01T23:59:59.000Z

303

Rational analysis of mass, momentum, and heat transfer phenomena in liquid storage tanks under realistic operating conditions: 1. Basic formulation  

SciTech Connect

This paper presents a computer code that analyses the performance of storage tanks using water as the working fluid. The new aspects of the authors work include the following items: (a) the transient Navier-Stokes equations are expressed in two-dimensional Cartesian and cylindrical coordinates, under the assumption of the Boussinesq approximation, (b) the effective viscosity and thermal diffusivity are evaluated by using a simplified form of the Deardorff turbulence model, (c) the energy equation is solved over a domain which includes the tank and a large portion of the surrounding soil, (d) some properly defined source terms have been introduced in the governing equations to describe inlet/outlet devices inside the tank, and localized friction losses, and (e) the boundary conditions are time-dependent to correctly describe the daily heat exchanges between tank, solar collectors and heat pumps for space conditioning. The Finite Differences (FD) technique and an improved formulation of the Marker and Cell (MAC) method are used to solve the conservation equations. Comparisons with literature studies indicate discrepancies between 0.02 and 0.5%. The results of several tests simulating realistic operating conditions will be shown in the second part of the paper.

Parrini, F.; Vitale, S.; Alabiso, M. (ENEL-Italian National Electricity Board-CRTN, Milan (Italy)); Castellano, L. (MATEC S.r.l., Milan (Italy))

1992-08-01T23:59:59.000Z

304

Analysis of radiation exposure for naval units of Operation Crossroads. Volume 2. (Appendix A) target ships. Technical report  

SciTech Connect

External radiation doses are reconstructed for crews of support and target ships of Joint Task Force One at Operation CROSSROADS, 1946. Volume I describes the reconstruction methodology, which consists of modeling the radiation environment, to include the radioactivity of lagoon water, target ships, and support ship contamination; retracing ship paths through this environment; and calculating the doses to shipboard personnel. The USS RECLAIMER, a support ship, is selected as a representative ship to demonstrate this methodology. Doses for all other ships are summarized. Volume II (Appendix A) details the results for target ship personnel. Volume III (Appendix B) details the results for support ship personnel. Calculated doses for more than 36,000 personnel aboard support ships while at Bikini range from zero to 1.7 rem. Of those, approximately 34,000 are less than 0.5 rem. From the models provided, doses due to target ship reboarding and doses accrued after departure from Bikini can be calculated, based on the individual circumstances of exposure.

Weitz, R.; Thomas, C.; Klemm, J.; Stuart, J.; Knowles, M.

1982-03-03T23:59:59.000Z

305

Analysis of radiation exposure for naval units of Operation Crossroads. Volume 3. (Appendix B) support ships. Technical report  

SciTech Connect

External radiation doses are reconstructed for crews of support and target ships of Joint Task Force One at Operation CROSSROADS, 1946. Volume I describes the reconstruction methodology, which consists of modeling the radiation environment, to include the radioactivity of lagoon water, target ships, and support ship contamination; retracing ship paths through this environment; and calculating the doses to shipboard personnel. The USS RECLAIMER, a support ship, is selected as a representative ship to demonstrate this methodology. Doses for all other ships are summarized. Volume II (Appendix A) details the results for target ship personnel. Volume III (Appendix B) details the results for support ship personnel. Calculated doses for more than 36,000 personnel aboard support ships while at Bikini range from zero to 1.7 rem. Of those approximately 34,000 are less than 0.5 rem. From the models provided, doses due to target ship reboarding and doses accrued after departure from Bikini can be calculated, based on the individual circumstances of exposure.

Weitz, R.; Thomas, C.; Klemm, J.; Stuart, J.; Knowles, M.

1982-03-03T23:59:59.000Z

306

Operations | National Nuclear Security Administration  

NLE Websites -- All DOE Office Websites (Extended Search)

| National Nuclear Security Administration | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Operations Home > About Us > Our Programs > Emergency Response > Responding to Emergencies > Operations Operations NNSA's Emergency Response Operations program acts as the headquarters command and control, functioning as the coordinating focal point for all

307

Operations | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

| National Nuclear Security Administration | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Operations Home > About Us > Our Programs > Emergency Response > Responding to Emergencies > Operations Operations NNSA's Emergency Response Operations program acts as the headquarters command and control, functioning as the coordinating focal point for all

308

Continuous Thermophilic Composting  

Science Journals Connector (OSTI)

...between 120 and 160 F. MATERIALS AND METHODS The composting...Figure 1 is a sectional diagram of the pilot plant and...addition and removal of material. During operation...problems connected with materials handling, and the value of the...

K. L. Schulze

1962-03-01T23:59:59.000Z

309

Business continuity planning for a U.S. supply chain  

E-Print Network (OSTI)

The research objective was to provide a directional sense of some key considerations for business continuity planning (BCP) specific to a company's downstream distribution operations in the U.S. This was achieved via a ...

Chee, Arthur K. L. (Arthur Kuan Loong)

2014-01-01T23:59:59.000Z

310

Embedding Continuous Commissioning in an Energy Efficiency Retrofit Program  

E-Print Network (OSTI)

his paper presents a case study where Continuous Commissioning (CC), a process that optimizes the HVAC system operation and controls to reduce the building energy consumption and improve comfort, was embedded as one Energy Cost Reduction Measure...

Martinez, J. T.; Claridge, D.; Baltazar-Cervantes, J. C.; Turner, W. D.; Wei, G.; Verdict, M.

2006-01-01T23:59:59.000Z

311

OPERATIONS (OPS)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

OPS) OPS) OBJECTIVE OPS.1 The formality and discipline of operations is adequate to conduct work safely and programs are in place to maintain this formality and discipline. (CR 13) Scope: The Conduct of Operations Program was evaluated during the recent KE Basin FTS ORR and was found to be adequately implemented. Based on this result and the subsequent program enhancements, the scope of the review is to be limited to the SWS operating and maintenance evolutions. Criteria * Programmatic elements of conduct of operations are in place for SWS operations. (DOE Order 5480.19) * The SWS operations personnel adequately demonstrate the principles of conduct of operations requirements during the shift performance period. (DOE Order 5480.19)

312

Continuing Education and Training Needs of the Southern Forest Industry.  

E-Print Network (OSTI)

of individuals. One group consisted of 177 industry exec utives who make decisions regarding the continuing ed ucation and training needs of their company personnel. Executives were selected from 58 wood-based companies operating in 14 southern states... of individuals. One group consisted of 177 industry exec utives who make decisions regarding the continuing ed ucation and training needs of their company personnel. Executives were selected from 58 wood-based companies operating in 14 southern states...

Thomas, John K.; Albrecht, Don E.; Lee, J. Charles; Klinoff, Roger

1985-01-01T23:59:59.000Z

313

Three-dimensional Numerical Analysis on Blade Response of Vertical Axis Tidal Current Turbine Under Operational Condition  

SciTech Connect

Tidal power as a large-scale renewable source of energy has been receiving significant attention recently because of its advantages over the wind and other renewal energy sources. The technology used to harvest energy from tidal current is called a tidal current turbine. Though some of the principles of wind turbine design are applicable to tidal current turbines, the design of latter ones need additional considerations like cavitation damage, corrosion etc. for the long-term reliability of such turbines. Depending up on the orientation of axis, tidal current turbines can be classified as vertical axis turbines or horizontal axis turbines. Existing studies on the vertical axis tidal current turbine focus more on the hydrodynamic aspects of the turbine rather than the structural aspects. This paper summarizes our recent efforts to study the integrated hydrodynamic and structural aspects of the vertical axis tidal current turbines. After reviewing existing methods in modeling tidal current turbines, we developed a hybrid approach that combines discrete vortex method -finite element method that can simulate the integrated hydrodynamic and structural response of a vertical axis turbine. This hybrid method was initially employed to analyze a typical three-blade vertical axis turbine. The power coefficient was used to evaluate the hydrodynamic performance, and critical deflection was considered to evaluate the structural reliability. A sensitivity analysis was also conducted with various turbine height-to-radius ratios. The results indicate that both the power output and failure probability increase with the turbine height, suggesting a necessity for optimal design. An attempt to optimize a 3-blade vertical axis turbine design with hybrid method yielded a ratio of turbine height to radius (H/R) about 3.0 for reliable maximum power output.

Li, Ye; Karri, Naveen K.; Wang, Qi

2014-04-30T23:59:59.000Z

314

Distillation by repeated measurements: Continuous spectrum case  

SciTech Connect

Repeated measurements on one part of a bipartite system strongly affect the other part that is not measured, the dynamics of which is regulated by an effective contracted evolution operator. When the spectrum of this operator is discrete, the nonmeasured system is driven into a pure state, irrespective of the initial state, provided that the spectrum satisfies certain conditions. We show here that, even in the case of continuous spectrum, an effective distillation can occur under rather general conditions. We confirm it by applying our formalism to a simple model.

Bellomo, Bruno; Compagno, Giuseppe [CNISM and Dipartimento di Scienze Fisiche ed Astronomiche, Universita di Palermo, via Archirafi 36, IT-90123 Palermo (Italy); Nakazato, Hiromichi [Department of Physics, Waseda University, Tokyo 169-8555 (Japan); Yuasa, Kazuya [Waseda Institute for Advanced Study, Waseda University, Tokyo 169-8050 (Japan)

2010-12-15T23:59:59.000Z

315

Agencies plan continued DOE landfill remediation  

NLE Websites -- All DOE Office Websites (Extended Search)

Agencies plan continued DOE landfill remediation Agencies plan continued DOE landfill remediation The U.S. Department of Energy (DOE), Idaho Department of Environmental Quality and U.S. Environmental Protection Agency have released a planning document that specifies how DOE will continue to remediate a landfill containing hazardous and transuranic waste at DOE's Idaho Site located in eastern Idaho. The Phase 1 Remedial Design/Remedial Action Work Plan for Operable Unit 7-13/14 document was issued after the September 2008 Record of Decision (ROD) and implements the retrieval of targeted waste at the Subsurface Disposal Area (SDA) within the Radioactive Waste Management Complex (RWMC). The SDA began receiving waste in 1952 and contains radioactive and chemical waste in approximately 35 acres of disposal pits, trenches and soil vaults.

316

Japan's Triple Disaster The Continuing News Story  

E-Print Network (OSTI)

Japan's Triple Disaster The Continuing News Story Dennis Normile Japan News Bureau Chief November not pragmatic." -Fumihiko Imamura #12;18 News Of The Week Does Japan Need Nuclear Power? #12;19 News & Analysis "People lost trust in TEPCO and the energy policy itself." -Shunsuke Managi #12;20 News Of The Week Japan

Napp, Nils

317

Performance analysis of regenerative organic Rankine cycle (RORC) using the pure working fluid and the zeotropic mixture over the whole operating range of a diesel engine  

Science Journals Connector (OSTI)

Abstract A regenerative organic Rankine cycle (RORC) system is designed to recover the exhaust heat of a diesel engine, and the influence of the intermediate pressure (the pressures at which the steam is extracted from the expander) on performance parameters such as net power output, thermal efficiency and mass flow rate of the working fluid are analyzed. The organic working fluids under investigation are \\{R245fa\\} and the zeotropic mixture isopentane/R245fa (in a 0.7/0.3 mol fraction). Based on initial calculations of RORC system performance, the intermediate pressure is set to 1.15 MPa for the RORC system when using isopentane/R245fa (in a 0.7/0.3 mol fraction) as the working fluid, and 1.2 MPa when using \\{R245fa\\} as the working fluid. A performance analysis of the RORC system using the two different working fluids is then conducted over the whole operating range of a diesel engine. The results show that the zeotropic mixture isopentane/R245fa (in a 0.7/0.3 mol fraction) performs better. Finally, a combined diesel engine and RORC system is defined to evaluate the performance improvement of such a combined system over the whole operating range. Results show that, for the combined system, a 10.54% improvement in power output and a 9.55% improvement in fuel economy can be achieved at the engine’s rated condition.

Jian Zhang; Hongguang Zhang; Kai Yang; Fubin Yang; Zhen Wang; Guangyao Zhao; Hao Liu; Enhua Wang; Baofeng Yao

2014-01-01T23:59:59.000Z

318

SPEAR Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Interface 1113 N. Kurita J. Langton Vacuum TSP's 1120 J. Corbett A. Terebilo MATLAB Applications - Basics 1121 F. Rafael Booster Kicker Upgrade, Operation Manual 1121...

319

operations center  

National Nuclear Security Administration (NNSA)

1%2A en Operations Center http:nnsa.energy.govaboutusourprogramsemergencyoperationscounterterrorismoperationscenter

...

320

EIS-0238-SA-01: Supplement Analysis | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8-SA-01: Supplement Analysis 8-SA-01: Supplement Analysis EIS-0238-SA-01: Supplement Analysis Continued Operations of Los Alamos National Laboratory The Department of Energy (DOE), Albuquerque Operations Office, has prepared a Supplemental Analysis (SA) to determine if the Site-Wide Environmental Impact Statement for Continued Operations of Los Alamos National Laboratory (SWEIS) adequately addresses the environmental effects of a proposal for modifying current methods utilized to receive and manage certain offsite unwanted radioactive sealed sources at Los Alamos National Laboratory or if additional documentation under the National Environmental Policy Act (NEPA) is needed.The proposal is entitled Offsite Source Recovery Project (OSRP). DOE/EIS-0238, Department of Energy, Albuquerque Operations Office,

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Spatial Analysis of Contaminants in 200 West Area Groundwater in Support of the 200-ZP-1 Operable Unit Pre-Conceptual Remedy Design  

SciTech Connect

This report documents a preliminary spatial and geostatistical analysis of the distribution of several contaminants of interest (COIs) in groundwater within the unconfined aquifer beneath the 200 West Area of the Hanford Site. The contaminant plumes of interest extend within the 200-ZP-1 and 200-UP-1 groundwater operable units. The COIs included in the PNNL study were carbon tetrachloride (CTET), technetium-99 (Tc-99), iodine-129 (I-129), chloroform, plutonium, uranium, trichloroethylene (TCE), and nitrate. The project included three tasks. Task 1 involved the development of a database that includes all relevant depth-discrete data on the distribution of COIs in the study area. The second task involved a spatial analysis of the three-dimensional (3D) distribution of data for the COIs in the study area. The main focus of the task was to determine if sufficient data are available for geostatistical mapping of the COIs in 3D. Task 3 involved the generation of numerical grids of the concentration of CTET, chloroform, and Tc-99.

Murray, Christopher J.; Bott, Yi-Ju

2008-12-30T23:59:59.000Z

322

Storage Ring Operation Modes  

NLE Websites -- All DOE Office Websites (Extended Search)

Longitudinal bunch profile and Up: APS Storage Ring Parameters Longitudinal bunch profile and Up: APS Storage Ring Parameters Previous: Source Parameter Table Storage Ring Operation Modes Standard Operating Mode, top-up Fill pattern: 102 mA in 24 singlets (single bunches) with a nominal current of 4.25 mA and a spacing of 153 nanoseconds between singlets. Lattice configuration: Low emittance lattice with effective emittance of 3.1 nm-rad and coupling of 1%. Bunch length (rms): 33.5 ps. Refill schedule: Continuous top-up with single injection pulses occurring at a minimum of two minute intervals, or a multiple of two minute intervals. Special Operating Mode - 324 bunches, non top-up Fill pattern: 102 mA in 324 uniformly spaced singlets with a nominal single bunch current of 0.31 mA and a spacing of 11.37 nanoseconds between singlets.

323

Nuclear radiation electronic gear (continued)  

Science Journals Connector (OSTI)

Nuclear radiation electronic gear (continued) ... Examines nuclear instrumentation available from several major U.S. manufacturers. ... Nuclear / Radiochemistry ...

S. Z. Lewin

1961-01-01T23:59:59.000Z

324

A Novel, Web-Driven Continuous Mining Steven J. Schafrik  

E-Print Network (OSTI)

A Novel, Web-Driven Continuous Mining Simulator By Steven J. Schafrik and Michael Karmis Department geometry of operations as well as other constraints. This paper presents WebConSim, a newly developed, Web underground and open-pit mining operations. OBJECTIVES AND DESIGN OF THE NEW WEB- BASED SIMULATOR One

325

Operations Research and Systems Analysis  

Science Journals Connector (OSTI)

...Introduction of more rapid depreciation for...redistribution. Modeling this situation called...development of an automated computer-based...usually called modeling today), problem...was to produce a rapid flow of theoretical...the theory of simulation is im-portant...

Hugh J. Miser

1980-07-04T23:59:59.000Z

326

Design operators  

E-Print Network (OSTI)

Design operators is a thesis that investigates the nature and characteristics of the design process by examining the interaction of computation with architectural design. The effects of the introduction of these media in ...

Dritsas, Stylianos, 1978-

2004-01-01T23:59:59.000Z

327

Business Operations  

Office of Energy Efficiency and Renewable Energy (EERE)

The Office of Business Operations is the central organization for all Office of Energy Efficiency and Renewable Energy (EERE) business products, processes, and systems. The three main offices of...

328

Operating Costs  

Directives, Delegations, and Requirements

This chapter is focused on capital costs for conventional construction and environmental restoration and waste management projects and examines operating cost estimates to verify that all elements of the project have been considered and properly estimated.

1997-03-28T23:59:59.000Z

329

Design of hot extrusion molding device for the continuous production of pharmaceutical tablets  

E-Print Network (OSTI)

Currently, pharmaceutical tablets are manufactured in large batch operations that have inefficiencies associated with the stopping, re-configuration and testing between batches. Continuous manufacturing has the potential ...

Zampierollo, Giorgio (Giorgio Romano)

2010-01-01T23:59:59.000Z

330

Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Analysis of core damage frequency from internal events during mid-loop operations, Appendices A--D. Volume 2, Part 2  

SciTech Connect

During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the Potential risks during low Power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the Plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this report is to document the approach utilized in the Surry plant and discuss the results obtained. A parallel report for the Grand Gulf plant is prepared by SNL. This study shows that the core-damage frequency during mid-loop operation at the Surry plant is comparable to that of power operation. We recognize that there is very large uncertainty in the human error probabilities in this study. This study identified that only a few procedures are available for mitigating accidents that may occur during shutdown. Procedures written specifically for shutdown accidents would be useful. This document, Volume 2, Pt. 2 provides appendices A through D of this report.

Chu, T.L.; Musicki, Z.; Kohut, P. [Brookhaven National Lab., Upton, NY (United States)] [and others

1994-06-01T23:59:59.000Z

331

Performance Analysis of AODV and DSDV Protocols Using RPGM Model for Application in Co-operative Ad-Hoc Mobile Robots  

Science Journals Connector (OSTI)

With the advancement in communication technology, the robotic researchers started to think in the direction of developing the co-operative mobile robot. These robots can co-operate with each other in ... in infra...

Rajesh P. Barnwal; Arnab Thakur

2012-01-01T23:59:59.000Z

332

DOE/EIS-0238, Site-Wide Environmental Impact Statement for Continued  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE/EIS-0238, Site-Wide Environmental Impact Statement for DOE/EIS-0238, Site-Wide Environmental Impact Statement for Continued Operation of the Los Alamos National Laboratory (1999) DOE/EIS-0238, Site-Wide Environmental Impact Statement for Continued Operation of the Los Alamos National Laboratory (1999) DOE proposes to continue operating the Los Alamos National Laboratory (LANL) located in Los Alamos County, in north-central New Mexico. DOE has identified and assessed four alternatives for the operation of LANL: (1) No Action, (2) Expanded Operations, (3) Reduced Operations, and (4) Greener. Expanded Operations is DOE's Preferred Alternative, with the exception that DOE would only implement pit manufacturing at a level of 20 pits per year. DOE/EIS-0238, Site-Wide Environmental Impact Statement for Continued Operation of the Los Alamos National Laboratory (1999)

333

Argon and neon plasma columns in continuous surface wave microwave discharge at atmospheric pressure  

Science Journals Connector (OSTI)

In this paper the results of experimental investigations of a surface wave sustained discharge during continuous mode of operation are given. The surfaguide based microwave plasma torch operated at frequency of 2...

D. Czylkowski; M. Jasi?ski; J. Mizeraczyk; Z. Zakrzewski

2006-10-01T23:59:59.000Z

334

Integration of Continuous Commissioning as a Measure in LoanSTAR and Energy Services Contracts  

E-Print Network (OSTI)

Continuous Commissioning (CC) is a process that resolves operating problems, optimizes the HVAC system operation and controls to reduce building energy consumption and improve comfort based on current building conditions and requirements...

Wei, G.; Zhou, J.; Turner, D.

335

Infrastructure and Operations | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Operations | National Nuclear Security Administration Operations | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Infrastructure and Operations Home > About Us > Our Operations > Infrastructure and Operations Infrastructure and Operations NNSA's missions require a secure production and laboratory infrastructure meeting immediate and long term needs. The Associate Administrator for

336

EVALUATION OF SPRING OPERATED RELIEF VALVE MAINTENANCE INTERVALS AND EXTENSION OF MAINTENANCE TIMES USING A WEIBULL ANALYSIS WITH MODIFIED BAYESIAN UPDATING  

SciTech Connect

The Savannah River Site (SRS) spring operated pressure relief valve (SORV) maintenance intervals were evaluated using an approach provided by the American Petroleum Institute (API RP 581) for risk-based inspection technology (RBI). In addition, the impact of extending the inspection schedule was evaluated using Monte Carlo Simulation (MCS). The API RP 581 approach is characterized as a Weibull analysis with modified Bayesian updating provided by SRS SORV proof testing experience. Initial Weibull parameter estimates were updated as per SRS's historical proof test records contained in the Center for Chemical Process Safety (CCPS) Process Equipment Reliability Database (PERD). The API RP 581 methodology was used to estimate the SORV's probability of failing on demand (PFD), and the annual expected risk. The API RP 581 methodology indicates that the current SRS maintenance plan is conservative. Cost savings may be attained in certain mild service applications that present low PFD and overall risk. Current practices are reviewed and recommendations are made for extending inspection intervals. The paper gives an illustration of the inspection costs versus the associated risks by using API RP 581 Risk Based Inspection (RBI) Technology. A cost effective maintenance frequency balancing both financial risk and inspection cost is demonstrated.

Harris, S.; Gross, R.; Mitchell, E.

2011-01-18T23:59:59.000Z

337

BOREAS Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Study Area Operations/Thompson Airport (NSA-Ops) Study Area Operations/Thompson Airport (NSA-Ops) NSA Operations (NSA-Ops) The Keewatin Air Hanger: site of BOREAS Ops 1994 Dr. Piers Sellers working in Ops, 1994 BOREAS "Air Force" The NASA C-130 The University of Wyoming King Air The NASA Helicopter The NRC Twin Otter The NCAR Electra The Ontario Chieftain Back to the BOREAS Photo Page Index Other Sites: NSA Photos ||NSA-BP Photos | NSA-Fen Photos | NSA-OA Photos | NSA-OBS Photos | NSA-OJP Photos | NSA-UBS Photos | NSA-YJP Photos | NSA-Ops Photos SSA Photos || SSA-Airport Photos | SSA-Fen Photos | SSA-Mix Photos | SSA-OA Photos | SSA-OBS Photos | SSA-OJP Photos | SSA-YA Photos | SSA-YJP Photos | SSA-Ops Photos | ORNL DAAC Home || ORNL Home || NASA || Privacy, Security, Notices || Data Citation || Rate Us || Help |

338

SSA Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Area Operations (SSA-Ops) Area Operations (SSA-Ops) "BOREAS Ops" was located at the Snodrifters Lodge, in Candle Lake, Saskatchewan. Radiosonde balloon launch at Ops The NASA Helicopter lands at Ops A meeting at the Snodrifter's Lodge Release of a radiosonde at the SSA operations center in Candle Lake. Back to the BOREAS Photo Page Index Other Sites: NSA Photos ||NSA-BP Photos | NSA-Fen Photos | NSA-OA Photos | NSA-OBS Photos | NSA-OJP Photos | NSA-UBS Photos | NSA-YJP Photos | NSA-Ops Photos SSA Photos || SSA-Airport Photos | SSA-Fen Photos | SSA-Mix Photos | SSA-OA Photos | SSA-OBS Photos | SSA-OJP Photos | SSA-YA Photos | SSA-YJP Photos | SSA-Ops Photos | ORNL DAAC Home || ORNL Home || NASA || Privacy, Security, Notices || Data Citation || Rate Us || Help | User Services - Tel: +1 (865) 241-3952 or E-mail: uso@daac.ornl.gov

339

Continual Learning | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Continual Learning Continual Learning Continual Learning Continual Learning Workshops Continual Learning is a change initiative which is used to help develop and grow a learning culture within DOE. The purpose of Continual Learning is to improve the professional development of our federal workforce. In an effort to support this initiative, HC-20 offers 3 instructional workshops, located under additional information, to assist employees and supervisors with employee development. These workshops are full of helpful tips and tricks for identifying low cost/no cost training, creating a high-quality IDP and assist supervisors with their responsibilities with employee development. Employees and supervisor are encouraged to attend these workshops and let us (HC-20) help you as we promote a learning

340

Institute of Nuclear Power Operations 1994 annual report  

SciTech Connect

This annual report highlights the activities of the Institute of Nuclear Power Operations. The topics of the report include the president and chairmen`s joint message, overview of programs serving as the foundation for most of its activities, performance indicators for the US nuclear utility industry, and INPO`s 1994 financial reports and rosters. INPO has four technical cornerstone programs that serve as the foundation for most of its activities. (1) Evaluations of nuclear power plants operated by member utilities are conducted on a regularly scheduled basis. (2) INPO supports its member utilities in their work to achieve and maintain accreditation of training programs. (3) Events analysis programs identify and communicate lessons learned from plant events so utilities can take action to prevent similar events at their plants. (4) INPO helps members improve in nuclear operations areas through assistance programs and other activities that continually evolve to meet the changing needs of the nuclear industry

NONE

1994-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

DOE/EIS-0225-SA-04: Supplement Analysis for the Final Environmental Impact Statement for the Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapon Components (October 2008)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

i i Table of Contents List of Figures ...............................................................................................................................................ii List of Tables ................................................................................................................................................ii List of Acronyms .........................................................................................................................................iii Metric Conversion Chart..............................................................................................................................iv Chapter 1 Introduction .........................................................................................................................

342

Continuous Change Institutional Change Principle  

Energy.gov (U.S. Department of Energy (DOE))

Because it takes time to establish institutional change, Federal agencies need multiyear plans that continuously work to achieve, reinforce, and improve significant and persistent sustainability...

343

Mercury Continuous Emmission Monitor Calibration  

SciTech Connect

Mercury continuous emissions monitoring systems (CEMs) are being implemented in over 800 coal-fired power plant stacks throughput the U.S. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor calibrators/generators. These devices are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 and vacated by a Federal appeals court in early 2008 required that calibration be performed with NIST-traceable standards. Despite the vacature, mercury emissions regulations in the future will require NIST traceable calibration standards, and EPA does not want to interrupt the effort towards developing NIST traceability protocols. The traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued a conceptual interim traceability protocol for elemental mercury calibrators. The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The EPA traceability protocol document is divided into two separate sections. The first deals with the qualification of calibrator models by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the calibrators that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma/mass spectrometry (ID/ICP/MS) performed by NIST in Gaithersburg, MD. The outputs of mercury calibrators are compared to one another using a nesting procedure which allows direct comparison of one calibrator with another at specific concentrations and eliminates analyzer variability effects. The qualification portion of the EPA interim traceability protocol requires the vendors to define calibrator performance as affected by variables such as pressure, temperature, line voltage, and shipping. In 2007 WRI developed and conducted a series of simplified qualification experiments to determine actual calibrator performance related to the variables defined in the qualification portion of the interim protocol.

John Schabron; Eric Kalberer; Ryan Boysen; William Schuster; Joseph Rovani

2009-03-12T23:59:59.000Z

344

Substation Operation  

Science Journals Connector (OSTI)

... THIS book is intended to help the workman to understand the principles of substation operation. It is a good attempt at giving somewhat advanced technical knowledge in such ... ." We are told not to use water to put out a fire at a substation before the station has been made completely " dead." The reason given for this ...

1925-08-01T23:59:59.000Z

345

Operation Diagnostics: Use of Visualization Techniques and Operation  

NLE Websites -- All DOE Office Websites (Extended Search)

Operation Diagnostics: Use of Visualization Techniques and Operation Operation Diagnostics: Use of Visualization Techniques and Operation Patterns to Verify and Optimize Dynamic Building and System Operation Speaker(s): Oliver Baumann Date: December 7, 2004 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Peng Xu Building automation systems (BAS) and building energy management systems (BEMS) have been used in modern edifices for the last 2 decades. These systems measure, process, and monitor a huge amount of data to operate the building and systems more or less properly. Often, the data is only used to signal failures or break-downs of systems or components. Further information of the data to analyze and diagnose the building operation is not used due to the lack of analysis methods and tools. Within the Operation Diagnostics, different visualization techniques are applied to

346

Distribution of Wind Power Forecasting Errors from Operational Systems (Presentation)  

SciTech Connect

This presentation offers new data and statistical analysis of wind power forecasting errors in operational systems.

Hodge, B. M.; Ela, E.; Milligan, M.

2011-10-01T23:59:59.000Z

347

Current drive operation in a tokamak  

Science Journals Connector (OSTI)

Three modes of current drive operation in a tokamak — continuous, cyclic, and rfinitiated-are ... A model design of a saturable iron core tokamak for current drive experiments is also presented.

O. Mitarai; A. Hirose

1985-12-01T23:59:59.000Z

348

EIS-0225-SA-01: Supplement Analysis | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1: Supplement Analysis 1: Supplement Analysis EIS-0225-SA-01: Supplement Analysis Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapon Components - AL-R8 Sealed Insert Container This SA is submitted according to the requirements for determining the need for supplemental EISs (10 CFR 1021.3(4) in DOE's regulations for NEPA implementation. This SA specifically addresses the issue of another type of container for the pit repackaging system. DOE/EIS-0225, Supplement Analysis for Final Environmental Impact Statement for the Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapon Components - AL-R8 Sealed Insert Container (August 1998) More Documents & Publications EIS-0225-SA-03: Supplement Analysis EIS-0225-SA-04: Supplement Analysis

349

EIS-0157-SA-01: Supplement Analysis | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EIS-0157-SA-01: Supplement Analysis EIS-0157-SA-01: Supplement Analysis EIS-0157-SA-01: Supplement Analysis Continued Operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore, Oakland Operations Office, Oakland, California Volume I: Main Report This supplement analysis (SA) was prepared in accordance with the requirements of the National Environmental Policy Act of 1969 (NEPA). It considers whether the Final Environmental Impact Statement and Environmental Impact Report for Continued Operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore (DOE 1992), hereafter referred to as the "1992 EIS/EIR," should be supplemented, a new environmental impact statement (EIS) should be prepared, or no further NEPA documentation is required. The main body of this SA focuses on the

350

Effect analysis of Reliability, Availability, Maintainability and Safety (RAMS ) Parameters in design and operation of Dynamic Positioning (DP) systems in floating offshore structures.  

E-Print Network (OSTI)

?? The objective of this thesis is to identify, which hazards and failures in operation process will affect Reliability, Availability, Maintainability and Safety of floating… (more)

Ebrahimi, Ali

2010-01-01T23:59:59.000Z

351

2011 Annual Workforce Analysis and Staffing Plan Report - EM Consolidated  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EM EM Consolidated Business Center 2011 Annual Workforce Analysis and Staffing Plan Report - EM Consolidated Business Center Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Individual site summaries developed at the end of each year are a basis for DOE Federal Technical Capability Panel reporting to the Secretary of Energy summarizing DOE's federal technical capabilities for defense nuclear facility safety assurance. 2011 Annual Workforce Analysis and Staffing Plan Report - EMCBC

352

2010 Annual Workforce Analysis and Staffing Plan Report - EM Consolidated  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EM EM Consolidated Business Center 2010 Annual Workforce Analysis and Staffing Plan Report - EM Consolidated Business Center Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Individual site summaries developed at the end of each year are a basis for DOE Federal Technical Capability Panel reporting to the Secretary of Energy summarizing DOE's federal technical capabilities for defense nuclear facility safety assurance. 2010 Annual Workforce Analysis and Staffing Plan Report - EMCBC

353

2012 Annual Workforce Analysis and Staffing Plan Report - EM Consolidated  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EM EM Consolidated Business Center 2012 Annual Workforce Analysis and Staffing Plan Report - EM Consolidated Business Center Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Individual site summaries developed at the end of each year are a basis for DOE Federal Technical Capability Panel reporting to the Secretary of Energy summarizing DOE's federal technical capabilities for defense nuclear facility safety assurance. 2012 Annual Workforce Analysis and Staffing Plan Report - EMCBC

354

Operation Poorman  

SciTech Connect

The objectives of Operation Poorman were to design and build a portable seismic system and to set up and use this system in a cold-weather environment. The equipment design uses current technology to achieve a low-power, lightweight system that is configured into three modules. The system was deployed in Alaska during wintertime, and the results provide a basis for specifying a mission-ready seismic verification system.

Pruvost, N.; Tsitouras, J.

1981-03-18T23:59:59.000Z

355

Report on System operation A background report prepared by the Nordel Operation  

E-Print Network (OSTI)

.................................................................................................................... 3 2 COOPERATION AND PRINCIPLES AGREED IN SYSTEM OPERATION AGREEMENT REGARDING POWER SHORTAGE will further improve the system security. Training of operation people is continuously important to be able in System Operation Agreement regarding power shortage and disturbance situations 2.1 Purpose of the System

356

Emergency Operations Training Academy | National Nuclear Security  

National Nuclear Security Administration (NNSA)

Operations Training Academy | National Nuclear Security Operations Training Academy | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Emergency Operations Training Academy Home > About Us > Our Programs > Emergency Response > Training > Emergency Operations Training Academy Emergency Operations Training Academy Rotating image showing pictures of Classroom, Online and Hands on trainings

357

Aerial survey of Bay Area continues through Saturday | National Nuclear  

National Nuclear Security Administration (NNSA)

of Bay Area continues through Saturday | National Nuclear of Bay Area continues through Saturday | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Aerial survey of Bay Area continues through Saturday Aerial survey of Bay Area continues through Saturday Posted By Office of Public Affairs NNSA Blog This week, a NNSA helicopter has been flying at a low-level altitude over

358

NNSA Continues Emergency Training in Taiwan | National Nuclear Security  

National Nuclear Security Administration (NNSA)

Continues Emergency Training in Taiwan | National Nuclear Security Continues Emergency Training in Taiwan | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > Media Room > Press Releases > NNSA Continues Emergency Training in Taiwan Press Release NNSA Continues Emergency Training in Taiwan Dec 20, 2013 WASHINGTON, D.C. - Under the auspices of the American Institute in Taiwan

359

2010 Annual Workforce Analysis and Staffing Plan Report - Richland  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2010 Annual Workforce Analysis and Staffing Plan Report - Richland 2010 Annual Workforce Analysis and Staffing Plan Report - Richland Operations Office 2010 Annual Workforce Analysis and Staffing Plan Report - Richland Operations Office Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Individual site summaries developed at the end of each year are a basis for DOE Federal Technical Capability Panel reporting to the Secretary of Energy summarizing DOE's federal technical capabilities for defense nuclear facility safety assurance.

360

2012 Annual Workforce Analysis and Staffing Plan Report - Richland  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2 Annual Workforce Analysis and Staffing Plan Report - Richland 2 Annual Workforce Analysis and Staffing Plan Report - Richland Operations Office 2012 Annual Workforce Analysis and Staffing Plan Report - Richland Operations Office Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Individual site summaries developed at the end of each year are a basis for DOE Federal Technical Capability Panel reporting to the Secretary of Energy summarizing DOE's federal technical capabilities for defense nuclear facility safety assurance.

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

JAPAN’S STRUGGLES CONTINUE  

Science Journals Connector (OSTI)

JAPAN EXPERIENCED progress and setbacks last week in its continuing struggle to recover from the devastating March 11 earthquake and tsunami. Frontline workers at the crippled Fukushima Daiichi Nuclear Power Station again risked their lives to tame ...

BRITT ERICKSON; JEFF JOHNSON; JEAN-FRANÇOIS TREMBLAY

2011-03-28T23:59:59.000Z

362

23 Optimization for Continuous Shortest  

E-Print Network (OSTI)

23 Optimization for Continuous Shortest Paths in Transportation J. Miguel Díaz-Báñez CONTENTS 23.1 Introduction and Motivation .................................................................... 497 23.2 Basic Terminology and Definitions......................................................... 499 23.3 Covering Short

Díaz-Báñez, José Miguel

363

Diesel prices continue to increase  

U.S. Energy Information Administration (EIA) Indexed Site

Diesel prices continue to increase The U.S. retail price for on-highway diesel fuel rose to its highest average since September at 3.95 a gallon. That's up 4.7 cents from a week...

364

Diesel prices continue to increase  

U.S. Energy Information Administration (EIA) Indexed Site

Diesel prices continue to increase The U.S. average retail price for on-highway diesel fuel rose to 3.91 a gallon on Monday. That's up 7-tenths of a penny from a week ago, based...

365

Diesel prices continue to increase  

U.S. Energy Information Administration (EIA) Indexed Site

Diesel prices continue to increase The U.S. average retail price for on-highway diesel fuel rose to 3.98 a gallon. That's up 2.6 cents from a week ago, based on the weekly price...

366

Reactor operation safety information document  

SciTech Connect

The report contains a reactor facility description which includes K, P, and L reactor sites, structures, operating systems, engineered safety systems, support systems, and process and effluent monitoring systems; an accident analysis section which includes cooling system anomalies, radioactive materials releases, and anticipated transients without scram; a summary of onsite doses from design basis accidents; severe accident analysis (reactor core disruption); a description of operating contractor organization and emergency planning; and a summary of reactor safety evolution. (MB)

Not Available

1990-01-01T23:59:59.000Z

367

Continuous space-time transformations  

E-Print Network (OSTI)

We prove that every continuous map acting on the four-dimensional Minkowski space and preserving light cones in one direction only is either a Poincar\\'e similarity, that is, a product of a Lorentz transformation and a dilation, or it is of a very special degenerate form. In the presence of the continuity assumption the main tool in the proof is a basic result from the homotopy theory of spheres.

Clément de Seguins Pazzis; Peter Šemrl

2015-02-04T23:59:59.000Z

368

Unsteady-state material balance model for a continuous rotary dissolver  

SciTech Connect

The unsteady-state continuous rotary dissolver material balance code (USSCRD) is a useful tool with which to study the performance of the rotary dissolver under a wide variety of operating conditions. The code does stepwise continuous material balance calculations around each dissolver stage and the digester tanks. Output from the code consists of plots and tabular information on the stagewise concentration profiles of UO{sub 2}, PuO{sub 2}, fission products, Pu(NO{sub 3}){sub 4}, UO{sub 2}(NO{sub 3}){sub 2}, fission product nitrates, HNO{sub 3}, H{sub 2}O, stainless steel, total particulate, and total fuel in pins. Other information about material transfers, stagewise liquid volume, material inventory, and dissolution performance is also provided. This report describes the development of the code, its limitations, key operating parameters, usage procedures, and the results of the analysis of several sets of operating conditions. Of primary importance in this work was the estimation of the steady-state heavy metal inventory in a 0.5-t/d dissolver drum. Values ranging from {similar_to}12 to >150 kg of U + Pu were obtained for a variety of operating conditions. Realistically, inventories are expected to be near the lower end of this range. Study of the variation of operating parameters showed significant effects on dissolver product composition from intermittent solids feed. Other observations indicated that the cycle times for the digesters and shear feed should be closely coupled in order to avoid potential problems with off-specification product. 19 references, 14 tables.

Lewis, B.E.

1984-09-01T23:59:59.000Z

369

EIS-0225-SA-04: Supplement Analysis | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5-SA-04: Supplement Analysis 5-SA-04: Supplement Analysis EIS-0225-SA-04: Supplement Analysis Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapon Components This second 5-Year update SA fulfills DOE's requirement to review the SWEIS at least every 5 years as required by 10 CFR 1021.330(d). This SA accomplishes that requirement by comparing the information presented in the SWEIS with changes and proposed changes, through 2011, in the environment and Pantex Plant missions, activities, programs, and impacts. DOE/EIS-0225-SA-04: Supplement Analysis for the Final Environmental Impact Statement for the Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapon Components (October 2008) More Documents & Publications EIS-0225-SA-05: Supplement Analysis

370

Survey your options: Continuous emissions monitoring  

SciTech Connect

In the US the public`s growing concern for air quality over the last twenty-five years has led to a complex patchwork of federal, state and local regulations aimed at controlling the emissions of pollutants from manufacturing facilities, power plants and municipal waste-incineration facilities. Like a shadow on the heels of a sprinter, the continuous emissions monitoring (CEM) industry has developed as a direct result of these regulations. In just two and a half decades, the CEM market has grown from a few specialized instrument firms to a billion-dollar business today--a remarkable feat considering there were few true CEM systems in existence prior to the enactment of the original US Clean Air Act of 1970. Despite the emergence of so many vendors offering so many different monitoring techniques, operators still face a host of complex issues when trying to select the right CEM. For facilities operating in today`s competitive, highly regulated environment, cost and performance pressures are stronger than ever. These pressures have forced CEM developers toward innovation to improve performance while containing capital and plant operating costs. This article provides an overview of the current status of CEM systems, and provides a glimpse at some of the new developments that will affect future monitoring configurations. Noteworthy new techniques include continuous emissions monitoring using Fourier Transform Infrared (FTIR) analyzers, laser-based opacity monitors, and the growing use of software-based, predictive CEMs. Also discussed is a new approach that overcomes the problems associated with measuring SO{sub 2} in fluegas streams downstream of NOx-reduction systems that use ammonia or urea injection.

White, J.R. [KVB/Analect, Irvine, CA (United States)

1995-07-01T23:59:59.000Z

371

Analysis of the operational reliability of a power-generating unit with a BN-600 reactor during the period 1980–1993  

Science Journals Connector (OSTI)

The high quality of the design and the additional improvements to separate units of the main equipment and systems at the initial stage of operation (first main circulation pump, steam generators, safety and c...

N. N. Oshkanov; A. G. Sheinkman; P. P. Govorov

1994-03-01T23:59:59.000Z

372

Testing robot controllers using constraint programming and continuous integration  

Science Journals Connector (OSTI)

AbstractContext Testing complex industrial robots (CIRs) requires testing several interacting control systems. This is challenging, especially for robots performing process-intensive tasks such as painting or gluing, since their dedicated process control systems can be loosely coupled with the robot’s motion control. Objective Current practices for validating \\{CIRs\\} involve manual test case design and execution. To reduce testing costs and improve quality assurance, a trend is to automate the generation of test cases. Our work aims to define a cost-effective automated testing technique to validate CIR control systems in an industrial context. Method This paper reports on a methodology, developed at ABB Robotics in collaboration with SIMULA, for the fully automated testing of \\{CIRs\\} control systems. Our approach draws on continuous integration principles and well-established constraint-based testing techniques. It is based on a novel constraint-based model for automatically generating test sequences where test sequences are both generated and executed as part of a continuous integration process. Results By performing a detailed analysis of experimental results over a simplified version of our constraint model, we determine the most appropriate parameterization of the operational version of the constraint model. This version is now being deployed at ABB Robotics’s CIR testing facilities and used on a permanent basis. This paper presents the empirical results obtained when automatically generating test sequences for \\{CIRs\\} at ABB Robotics. In a real industrial setting, the results show that our methodology is not only able to detect reintroduced known faults, but also to spot completely new faults. Conclusion Our empirical evaluation shows that constraint-based testing is appropriate for automatically generating test sequences for \\{CIRs\\} and can be faithfully deployed in an industrial context.

Morten Mossige; Arnaud Gotlieb; Hein Meling

2015-01-01T23:59:59.000Z

373

Schrödinger operators on armchair nanotubes. II  

E-Print Network (OSTI)

We consider the Schr\\"odinger operator with a periodic potential on quasi-1D models of armchair single-wall nanotubes. The spectrum of this operator consists of an absolutely continuous part (intervals separated by gaps) plus an infinite number of eigenvalues with infinite multiplicity. We describe the absolutely continuous spectrum of the Schr\\"odinger operator: 1) the multiplicity, 2) endpoints of the gaps, they are given by periodic or antiperiodic eigenvalues or resonances (branch points of the Lyapunov function), 3) resonance gaps, where the Lyapunov function is non-real. We determine the asymptotics of the gaps at high energy.

Andrey Badanin; Jochen Brüning; Evgeny Korotyaev

2007-07-26T23:59:59.000Z

374

Continuing Development of Models Based on Spherical Geodesic Grids  

E-Print Network (OSTI)

Continuing Development of Models Based on Spherical Geodesic Grids Ross Heikes, Joon-Hee Jung, C to finite-difference operators 3) Some numerical results from an aqua-planet simulation #12;Part1: Geodesic -- array based The geodesic grid can be mapped to a set of square arrays. 1 3 4 5 6 7 8 9 10 11 12 13 14 15

Collett Jr., Jeffrey L.

375

Post-doc: Modelling & Control of Continuous Reactors  

E-Print Network (OSTI)

development in mechatronics and microsystems, sustainable industrial processes, transportation systems scope is a demonstration of continuous reactors with in-line analytics for fine chemical production for improvement of operation and actuation and will provide data for sensor development and control guidelines. 4

Langendoen, Koen

376

Continuous PEPA queues: individual behaviour in continuous queueing networks  

Science Journals Connector (OSTI)

The PEPA Queues formalism augments queueing networks with customers that have behavioural characteristics defined in the popular stochastic process algebra, PEPA. Networks of PEPA Queues suffer from the traditional state space explosion that affects ... Keywords: ODEs, PEPA, continuous approximation, queueing networks

Ashok Argent-Katwala; Jeremy T. Bradley

2007-10-01T23:59:59.000Z

377

Ethics and continuing engineering education  

Science Journals Connector (OSTI)

The paper discusses the importance of ethics to engineers within a stakeholder approach. The role of ethics and continuing engineering education and training is developed with reference to professional codes and rules of conduct. A schematic framework is constructed to emphasise the various ingredients and outcomes of the continuing engineering education and ethics processes. Management has a moral duty to ensure that these are effectively provided, whilst at the same time to become role models. The importance of environmental awareness, responsibility and training is highlighted in relation to the technological and business scenario.

Alan Stainer

1997-01-01T23:59:59.000Z

378

Uncertainty in Particle Number Modal Analysis during Transient Operation of Compressed Natural Gas, Diesel, and Trap-Equipped Diesel Transit Buses  

Science Journals Connector (OSTI)

A number of recent studies have examined the mass- and number-weighted particulate emissions from diesel engines and vehicles, chiefly using laboratory tests under steady-state vehicle or engine operation. ... However, there remains little fundamental data on the relationships between vehicle operating mode (cruise, idle, acceleration, decelera tion) and ultrafine particle emissions, both for diesel and especially for diesel alternatives. ... The number of ELPI data points measured for individual test cycles ranged from 120 to 1000, depending on the recorded ELPI time resolution and overall length of the driving cycle (?10?35 min). ...

Britt A. Holmén; Yingge Qu

2004-03-10T23:59:59.000Z

379

Office of Headquarters Security Operations  

Energy.gov (U.S. Department of Energy (DOE))

The Office of Headquarters Security Operations strengthens national security by protecting personnel, facilities, property, classified information, and sensitive unclassified information for DOE Headquarters facilities in the National Capital Area under normal and abnormal (i.e., emergency) conditions; managing access authorization functions for Headquarters; ensuring that executives and dignitaries are fully protected, and supporting efforts to ensure the continuity of government in all circumstances as mandated by Presidential Decision Directive.

380

Business Operations | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Business Operations Business Operations Business Operations The Office of Business Operations is the central organization for all Office of Energy Efficiency and Renewable Energy (EERE) business products, processes, and systems. The three main offices of Business Operations - Office of Budget, Office of Business Services, and Office of Information and Business Management - and their managers are outlined in the Business Operations organization chart. Offices Image of the Department of Energy Forrestal building in DC. Office of Budget The Office of Budget provides information that informs policy development and program planning, including basic market and economic data relevant to EERE's programs, market and economic analysis, estimation of the public benefits of EERE's programs, evaluation of past program performance and

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Diesel prices continue to rise  

U.S. Energy Information Administration (EIA) Indexed Site

Diesel prices continue to rise The U.S. average retail price for on-highway diesel fuel rose to 4.16 a gallon on Monday. That's up 5.3 cents from a week ago, based on the weekly...

382

Continuous-wave organic dye lasers and methods  

DOE Patents (OSTI)

An organic dye laser produces a continuous-wave (cw) output without any moving parts (e.g., without using flowing dye streams or spinning discs of solid-state dye media to prevent photobleaching) and with a pump beam that is stationary with respect to the organic dye medium. The laser's resonant cavity, organic dye medium, and pump beam are configured to excite a lasing transition over a time scale longer than the associated decay lifetimes in the organic dye medium without photobleaching the organic dye medium. Because the organic dye medium does not photobleach when operating in this manner, it may be pumped continuously so as to emit a cw output beam. In some examples, operation in this manner lowers the lasing threshold (e.g., to only a few Watts per square centimeter), thereby facilitating electrical pumping for cw operation.

Shapira, Ofer; Chua, Song-Liang; Zhen, Bo; Lee, Jeongwon; Soljacic, Marin

2014-09-16T23:59:59.000Z

383

A Retrospective Analysis of Risk Factors of Central Nervous System Metastases in Operable Breast Cancer: Different Survival by Biological Subtype and Ki67 Overexpression.  

Science Journals Connector (OSTI)

...Antonio, TX P4-17-11: Central Nervous System Involvement and Clinical Outcome, Review...cancer infiltrates into central nervous system (CNS) with the incidence of 10-20...122 patients received irradiation or operation, and 118 died. While major cause of...

M. Ishihara; H. Mukai; M. Onozawa; K. Nihei; T. Shimada; N. Wada; and S. Nagai

2009-12-15T23:59:59.000Z

384

Maximum likelihood continuity mapping for fraud detection  

SciTech Connect

The author describes a novel time-series analysis technique called maximum likelihood continuity mapping (MALCOM), and focuses on one application of MALCOM: detecting fraud in medical insurance claims. Given a training data set composed of typical sequences, MALCOM creates a stochastic model of sequence generation, called a continuity map (CM). A CM maximizes the probability of sequences in the training set given the model constraints, CMs can be used to estimate the likelihood of sequences not found in the training set, enabling anomaly detection and sequence prediction--important aspects of data mining. Since MALCOM can be used on sequences of categorical data (e.g., sequences of words) as well as real valued data, MALCOM is also a potential replacement for database search tools such as N-gram analysis. In a recent experiment, MALCOM was used to evaluate the likelihood of patient medical histories, where ``medical history`` is used to mean the sequence of medical procedures performed on a patient. Physicians whose patients had anomalous medical histories (according to MALCOM) were evaluated for fraud by an independent agency. Of the small sample (12 physicians) that has been evaluated, 92% have been determined fraudulent or abusive. Despite the small sample, these results are encouraging.

Hogden, J.

1997-05-01T23:59:59.000Z

385

H-coal pilot plant. Phase II. Construction. Phase III. Operation. Annual report No. 3  

SciTech Connect

At the request of DOE Oak Ridge, ASFI agreed to assume responsibility for completion of Plant construction in December, 1979, at which time Badger Plants' on-site work was ended. This construction effort consisted of electric heat tracing and insulation of piping and instrumentation. At the close of the reporting period the work was completed, or was projected to be completed, within the ASFI budgeted amounts and by dates that will not impact Plant operations. Engineering design solutions were completed for problems encountered with such equipment as the High Pressure Letdown Valves; Slurry Block Valves; Slurry Pumps; the Bowl Mill System; the Dowtherm System; and the Ebullating Pump. A Corrosion Monitoring Program was established. With the exception of Area 500, the Antisolvent Deashing Unit, all operating units were commissioned and operated during the reporting period. Coal was first introduced into the Plant on May 29, 1980, with coal operations continuing periodically through September 30, 1980. The longest continuous coal run was 119 hours. A total of 677 tons of Kentucky No. 11 Coal were processed during the reporting period. The problems encountered were mechanical, not process, in nature. Various Environmental and Health programs were implemented to assure worker safety and protection and to obtain data from Plant operations for scientific analysis. These comprehensive programs will contribute greatly in determining the acceptability of long term H-Coal Plant operations.

Not Available

1981-02-04T23:59:59.000Z

386

EIS-0238-SA-04: Supplement Analysis | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4: Supplement Analysis 4: Supplement Analysis EIS-0238-SA-04: Supplement Analysis Continued Operation of Los Alamos National Laboratory: Recovery and Storage of Strontium-90 (Sr-90) Fueled Radioisotope Thermal Electric Generators at Los Alamos National Laboratory This SA specifically compares key impact assessment parameters of this proposal to the offsite source recovery program evaluated in the SWEIS and a subsequent SA that evaluated a change to the approach of a portion of the recovery program. It also provides an explanation of any differences between the Proposed Action and activities described in the previous SWEIS and SA analyses. DOE/EIS-0238, Supplement Analysis Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory: Recovery and

387

EIS-0225-SA-02: Final Supplement Analysis | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2: Final Supplement Analysis 2: Final Supplement Analysis EIS-0225-SA-02: Final Supplement Analysis Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapons Components Hazardous Waste Treatment and Processing Facility This SA specifically addresses the issue of housing liquid processes in a separate building, the elimination of forklift airlocks and overhead hoists from the main HWTPF, the handling of classified material, and the construction of a ramp instead of a shipping dock. DOE/EIS-0225, Final Supplement Analysis for the Final Environmental Impact Statement for the Continued Operation of the Pantex Plant and Associated Storage of Nuclear Weapons Components Hazardous Waste Treatment and Processing Facility (January 2000) More Documents & Publications

388

Continuous Diagnostics Advisor | Open Energy Information  

Open Energy Info (EERE)

Continuous Diagnostics Advisor Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Continuous Diagnostics Advisor AgencyCompany Organization: Johnson Controls Sector:...

389

Advisory Committee Recommends Continued Investment in Jefferson...  

NLE Websites -- All DOE Office Websites (Extended Search)

Advisory Committee Recommends Continued Investment in Jefferson Lab fellowship This aerial view of the Continuous Electron Beam Accelerator Facility shows the footprint of the...

390

Advisory Committee Recommends Continued Investment in Jefferson...  

NLE Websites -- All DOE Office Websites (Extended Search)

Advisory Committee Recommends Continued Investment in Jefferson Lab This aerial view of the Continuous Electron Beam Accelerator Facility shows the footprint of the accelerator and...

391

Best Practices for Continuing Training  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE-HDBK-1118-99 Reaffirmed January 2014 Superseding DOE-STD-1060-93 February 1993 DOE HANDBOOK BEST PRACTICES FOR CONTINUING TRAINING U.S. Department of Energy AREA TRNG Washington, D.C. 20585 NOT MEASUREMENT SENSITIVE This document has been reproduced from the best available copy. Available to DOE and DOE contractors from ES&H Technical Information Services, U.S. Department of Energy, (800) 473-4375, fax: (301) 903-9823. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 605-6000. DOE HDBK-1118-99 Errata January 2014 Table of Changes Page/Section Change Page 0 Best Practices for Continuing Training Page i/Section 2

392

Plant-life extension planning for an operating LMFBR  

SciTech Connect

The study concluded that continued EBR-II operation is certainly feasible for well beyond 10 more years, and that continued demonstration of the unique inherent safety and operability features of a pool-type liquid-metal-cooled reactor and the demonstration of a reasonable operating lifetime are very important and will provide invaluable information for the design and development of the next generation nuclear power plants.

King, R.W.

1985-01-01T23:59:59.000Z

393

EIS-0238-SA-02: Supplement Analysis  

Energy.gov (U.S. Department of Energy (DOE))

Continued Operation of Los Alamos National Laboratory: Modification of Management Methods for Transuranic Waste Characterization at Los Alamos National Laboratory

394

EIS-0225-SA-03: Supplement Analysis  

Energy.gov (U.S. Department of Energy (DOE))

Continued Operation of the National Nuclear Security Administration, Pantex Plant and Associated Storage of Nuclear Weapon Components

395

DOE-ID Operations Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

18, 2013 18, 2013 DOE-ID Operations Summary For the Period September 30, 2013 through October 31, 2013 EDITOR'S NOTE: The following is a summary of contractor operations at the Idaho National Laboratory, managed by DOE- Idaho Operations Office. It has been compiled in response to a request from stakeholders for more information on health, safety and environmental incidents at DOE facilities in Idaho. It also includes a brief summary of accomplishments at the Site. POC -Danielle Miller, (208) 526-5709. Advanced Mixed Waste Treatment Project (AMWTP) October 15, 2013: A manager at the Advanced Mixed Waste Treatment Project (AMWTP) determined that the AMWTP Safety Analysis process required review due to an operational trend of fire/combustion events in the Treatment Facility (TF) box lines. Safety analysis for the TF is

396

2010 Workforce Analysis and Staffing Plan Report Memo, Guidance and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0 Workforce Analysis and Staffing Plan Report Memo, Guidance and 0 Workforce Analysis and Staffing Plan Report Memo, Guidance and Template 2010 Workforce Analysis and Staffing Plan Report Memo, Guidance and Template The Department of Energy Federal Technical Capability Order, DOE 0 426.1, requires that managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Memo and Workforce Analysis Guidance for FR, SSO, STSM & TQP Template-2010.docx Description TEMPLATE More Documents & Publications 2010 Annual Workforce Analysis and Staffing Plan Report - Carlsbad Field

397

2011 Workforce Analysis and Staffing Plan Report Memo, Guidance and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 Workforce Analysis and Staffing Plan Report Memo, Guidance and 1 Workforce Analysis and Staffing Plan Report Memo, Guidance and Template 2011 Workforce Analysis and Staffing Plan Report Memo, Guidance and Template The Department of Energy Federal Technical Capability Order, DOE 0 426.1, requires that managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Memo and Workforce Analysis Guidance for FR, SSO, STSM & TQP Template-2011.docx Description TEMPLATE More Documents & Publications 2012 Workforce Analysis and Staffing Plan Report Memo, Guidance and

398

2012 Workforce Analysis and Staffing Plan Report Memo, Guidance and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Workforce Analysis and Staffing Plan Report Memo, Guidance and Workforce Analysis and Staffing Plan Report Memo, Guidance and Template 2012 Workforce Analysis and Staffing Plan Report Memo, Guidance and Template The Department of Energy Federal Technical Capability Order, DOE O 426.1, requires that managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Memo and Workforce Analysis Guidance for FR, SSO, STSM & TQP Template-2012.docx Description TEMPLATE More Documents & Publications 2010 Workforce Analysis and Staffing Plan Report Memo, Guidance and

399

2013 Workforce Analysis and Staffing Plan Report Memo, Guidance and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3 Workforce Analysis and Staffing Plan Report Memo, Guidance and 3 Workforce Analysis and Staffing Plan Report Memo, Guidance and Template 2013 Workforce Analysis and Staffing Plan Report Memo, Guidance and Template The Department of Energy Federal Technical Capability Order, DOE 0 426.1, requires that managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Memo and Workforce Analysis Guidance for FR, SSO, STSM & TQP Template-2013.docx Description TEMPLATE More Documents & Publications 2012 Workforce Analysis and Staffing Plan Report Memo, Guidance and

400

Formal Specification of Operating System Operations  

E-Print Network (OSTI)

Formal Specification of Operating System Operations Dan Zhou Department of Computer Science.black@nist.gov This paper describes the development of a formal specification for a secure operating system architecture operations. We also provide a uniform environment for system commands that change the security state

Black, Paul E.

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Twenty Years of Tevatron Operation  

Science Journals Connector (OSTI)

The superconducting Tevatron accelerator at Fermi National Accelerator Laboratory (Fermilab) has surpassed twenty years of operation. The Tevatron is still the highest energy particle accelerator in the world and will remain so until the commissioning of the LHC in Europe later this decade. The Tevatron has operated in a Fixed Target mode accelerating a proton beam into stationary targets/detectors as well as a Colliding Beam mode continuously colliding counter rotating beams of protons and antiprotons. Upon completion the Tevatron cryogenic system became the world’s largest helium refrigeration system. In 1993 the Tevatron cryogenic system was given the designation of International Historic Mechanical Engineering Landmark by the American Society of Mechanical Engineers. The operational history experiences and statistics of the Tevatron with an emphasis on the cryogenic system is presented. Improvements upgrades and current challenges of the cryogenic system are discussed.

J. C. Theilacker

2004-01-01T23:59:59.000Z

402

Geological structures from downward continuation of gravity anomalies  

E-Print Network (OSTI)

operator and two grid spacings (2 and 4 km), the depth to the upper surface of the source is about 4 km, with the center of' mass located at about 8 km. Comparison of these results with those for a sphere yield a density contrast of 0. 3 g/cc . Both... km 18. Downward-continuation residual gravity map and profile at the depth of 6 km. Contours in mGals. Grid spacing 4 km by 4 km 19. Downward-continuation residual gravity map and profile at the depth of 8 km. Contours in mGals. Grid spacing 4 km...

Yao, Chia-Chi George

2012-06-07T23:59:59.000Z

403

Headquarters Security Operations | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Headquarters Security Operations Headquarters Security Operations Headquarters Security Operations Mission The Office of Headquarters Security Operations strengthens national security by protecting personnel, facilities, property, classified information, and sensitive unclassified information for DOE Headquarters facilities in the National Capital Area under normal and abnormal (i.e., emergency) conditions; managing access authorization functions; ensuring that executives and dignitaries are fully protected, and supporting efforts to ensure the continuity of government in all circumstances as mandated by Presidential Decision Directive. The Office is the database owner for the principal personnel security information processing activities of the Department and personnel security administrative review process.

404

Rational analysis of mass, momentum, and heat transfer phenomena in liquid storage tanks under realistic operating conditions: 2. Application to a feasibility study  

Science Journals Connector (OSTI)

This is the second part of a two-part paper that deals with modelling the thermal performances of storage tanks of liquid water coupled with solar-assisted heatpump systems. The computer code THESTA, described in detail in the first part, has been applied to compare configurations which differ from one another in the distribution and thickness of the insulating panels. These numerical experiments show very clearly the capability of the code in simulating realistic operating conditions. The validity of the present release is also discussed. The results obtained have been assumed to be a reliable theoretical support to the definition of the features of the storage device of a pilot plant.

F. Parrini; S. Vitale; L. Castellano

1992-01-01T23:59:59.000Z

405

###Operating Principles published 411.pdf  

NLE Websites -- All DOE Office Websites (Extended Search)

Analysis of operating principles with S-system models Yun Lee 1 , Po-Wei Chen 1 , Eberhard O. Voit ⇑ The Wallace H. Coulter Department of Biomedical Engineering, Georgia Tech and Emory University, 313 Ferst Drive, Suite 4103, Atlanta, GA 30332-0535, United States a r t i c l e i n f o Article history: Available online 4 March 2011 Keywords: Biochemical Systems Theory Design principle Heat stress Operating principle S-system Trehalose a b s t r a c t Operating principles address general questions regarding the response dynamics of biological systems as we observe or hypothesize them, in comparison to a priori equally valid alternatives. In analogy to design principles, the question arises: Why are some operating strategies encountered more frequently than others and in what sense might they be superior? It is at this point impossible to study operation prin- ciples in complete generality,

406

REAL TIME SYSTEM OPERATIONS 2006-2007  

SciTech Connect

The Real Time System Operations (RTSO) 2006-2007 project focused on two parallel technical tasks: (1) Real-Time Applications of Phasors for Monitoring, Alarming and Control; and (2) Real-Time Voltage Security Assessment (RTVSA) Prototype Tool. The overall goal of the phasor applications project was to accelerate adoption and foster greater use of new, more accurate, time-synchronized phasor measurements by conducting research and prototyping applications on California ISO's phasor platform - Real-Time Dynamics Monitoring System (RTDMS) -- that provide previously unavailable information on the dynamic stability of the grid. Feasibility assessment studies were conducted on potential application of this technology for small-signal stability monitoring, validating/improving existing stability nomograms, conducting frequency response analysis, and obtaining real-time sensitivity information on key metrics to assess grid stress. Based on study findings, prototype applications for real-time visualization and alarming, small-signal stability monitoring, measurement based sensitivity analysis and frequency response assessment were developed, factory- and field-tested at the California ISO and at BPA. The goal of the RTVSA project was to provide California ISO with a prototype voltage security assessment tool that runs in real time within California ISO?s new reliability and congestion management system. CERTS conducted a technical assessment of appropriate algorithms, developed a prototype incorporating state-of-art algorithms (such as the continuation power flow, direct method, boundary orbiting method, and hyperplanes) into a framework most suitable for an operations environment. Based on study findings, a functional specification was prepared, which the California ISO has since used to procure a production-quality tool that is now a part of a suite of advanced computational tools that is used by California ISO for reliability and congestion management.

Eto, Joseph H.; Parashar, Manu; Lewis, Nancy Jo

2008-08-15T23:59:59.000Z

407

(sanitary) landfill operator  

Science Journals Connector (OSTI)

(sanitary) landfill operator, Müllkippenbetreiber m, Mülldeponiebetreiber, Kippenbetreiber, Deponiebetreiber

2014-08-01T23:59:59.000Z

408

The Joint Institute for Strategic Energy Analysis is operated by the Alliance for Sustainable Energy, LLC, on behalf of the U.S. Department of Energy's  

E-Print Network (OSTI)

of the INL- JISEA Workshop on Nuclear Hybrid Energy Systems Mark Antkowiak and Mark Ruth National Renewable 80401 303-275-3000 · www.jisea.org Contract No. DE-AC36-08GO28308 Summary Report of the INL- JISEA by the Joint Institute for Strategic Energy Analysis (JISEA) and the Idaho National Laboratory (INL

409

Operations Directorate (OPS Directorate)  

NLE Websites -- All DOE Office Websites (Extended Search)

Operations Directorate (OPS Directorate) Operations Directorate (OPS Directorate) Purpose A group chartered by the Associate Laboratory Director for the Advanced Photon Source that includes the responsible Division Directors and other appropriate APS operations personnel. The Operations Directorate collectively coordinates operating decisions that affect the facility as a whole and establishes both long- and short-term schedules, including scheduled maintenance and facility improvement periods. The Operations Directorate is the APS forum in which decisions regarding operations are discussed: These include, but are not limited to: Safety issues related to operations Operational Schedule Global operating parameters within the defined and approved operational and safety envelopes, such as energy, maximum circulating beam

410

Hermitian Young operators  

SciTech Connect

Starting from conventional Young operators, we construct Hermitian operators which project orthogonally onto irreducible representations of the (special) unitary group.

Keppeler, Stefan, E-mail: stefan.keppeler@uni-tuebingen.de [Mathematisches Institut, Universität Tübingen, Auf der Morgenstelle 10, 72076 Tübingen (Germany)] [Mathematisches Institut, Universität Tübingen, Auf der Morgenstelle 10, 72076 Tübingen (Germany); Sjödahl, Malin, E-mail: malin.sjodahl@thep.lu.se [Department of Astronomy and Theoretical Physics, Lund University, Sölvegatan 14A, 223 62 Lund (Sweden)] [Department of Astronomy and Theoretical Physics, Lund University, Sölvegatan 14A, 223 62 Lund (Sweden)

2014-02-15T23:59:59.000Z

411

Do Multielement Visual Tracking and Visual Search Draw Continuously on the Same Visual Attention Resources?  

E-Print Network (OSTI)

the attentional operating characteristic (AOC) method to determine whether both tasks draw continuously tasks were mutually exclusive. In fact, the AOC for tracking and search is similar to that for tracking

412

Air Pollution Control Regulations: No. 6- Continuous Emissions Monitors and Opacity Monitors (Rhode Island)  

Energy.gov (U.S. Department of Energy (DOE))

Stationary sources, including fossil fuel fired steam or hot water generating units, may be required to install and operate a continuous emissions monitoring system equipped with an opacity monitor...

413

Fact #719: March 19, 2012 Nearly 14% of New Car Sales have Continuously Variable Transmissions  

Energy.gov (U.S. Department of Energy (DOE))

Continuously variable transmissions (CVT) offer an infinite number of gear ratios that allow the engine to operate near peak efficiency throughout a wide range of vehicle speeds which improves fuel...

414

Lessons and Measures Learned from Continuous Commissioning(SM) of Central Chilled/Hot Water Systems  

E-Print Network (OSTI)

water and hot water system operation. It can be performed before, during, or after building side continuous commissioning. Successful central chilled/hot water system CC not only results in improved production and distribution, but also achieves...

Deng, S.; Turner, W. D.; Claridge, D. E.; Bruner, H.; Chen, H.; Wei, G.

2001-01-01T23:59:59.000Z

415

Magnetic Schrödinger operators on armchair nanotubes  

E-Print Network (OSTI)

We consider the Schr\\"odinger operator with a periodic potential on a quasi 1D continuous periodic model of armchair nanotubes in $\\R^3$ in a uniform magnetic field (with amplitude $B\\in \\R$), which is parallel to the axis of the nanotube. The spectrum of this operator consists of an absolutely continuous part (spectral bands separated by gaps) plus an infinite number of eigenvalues with infinite multiplicity. We describe all eigenfunctions with the same eigenvalue including compactly supported. We describe the spectrum as a function of $B$. For some specific potentials we prove an existence of gaps independent on the magnetic field. If $B\

Evgeny Korotyaev; Andrey Badanin

2008-04-01T23:59:59.000Z

416

Operations research and systems analysis of geopressured-geothermal energy in Louisiana. Final report for the period June 1, 1978-August 31, 1979  

SciTech Connect

The primary purpose was to provide a projection of the probable future contribution of the geopressured-geothermal energy resource in Louisiana to the overall energy requirements of the nation. A number of associated objectives were emphasized: namely, development of the tools and methodology for performing economic analyses, application of these tools to specific prospects about which adequate resource assessments have been made, identification of the impediments to resource development, and socio-economic analysis of the impact of development of the resource on these specific prospects. An overview of the geopressured-geothermal resource activities in Louisiana is provided first, followed by a detailed discussion and review of the achievements of this project. Finally the major conclusions and findings of this project with respect to commercial viability, impediments, and social and economic impact are presented, and recommendations are made for future systems analysis work.

Johnson, A.E. Jr.

1980-11-01T23:59:59.000Z

417

Use of continuous emission monitoring in the electric utility industry. Paper 81. 48. 3  

SciTech Connect

Steam electric generating plants are subject to continuous monitoring regulations. Reliable emission data are recorded to be reported to regulatory agencies. The continuous monitor is being used as a diagnostic tool for optimizing operation of control equipment also. Monitored data identify the magnitude, duration, and time of any emissions exceeding compliance standards so that corrective actions may be taken.

Van Gieson, J.

1981-01-01T23:59:59.000Z

418

Theoretical modeling and analysis of mechanical impact driven and frequency up-converted piezoelectric energy harvester for low-frequency and wide-bandwidth operation  

Science Journals Connector (OSTI)

Abstract Vibration energy harvesters are capable of generating significant amount of power at higher frequencies rather than generating at low frequencies. Moreover, as low frequency vibrations (1–30 Hz) around the ambient environment are discursive in nature, resonance based power generators are limited to use within this low frequency range. In this paper, a mechanical impact driven and frequency up-converted wide-bandwidth piezoelectric vibration energy harvester has been proposed and demonstrated theoretically and experimentally. It converts low frequency environmental vibrations into high frequency vibration by mechanical impact. A low frequency flexible driving beam with horizontally extended tip mass, upon excitation, hits two high frequency rigid piezoelectric generating beams at the same time causing a change in the driving beam's effective stiffness that allows the device to offer approximately 180% increased ?3 dB bandwidth and more than 62% of the maximum power generation within the remaining operating frequency range as well. The overall bandwidth is 7.5 Hz within 7–14.5 Hz frequency range generating a minimum peak power of 233 ?W. A maximum of 378 ?W peak power from one generating beam is achieved under 6 ms?2 acceleration at the resonant frequency of 14.5 Hz. Output of both generating beams connected in series produces 734 ?W peak power under the same operating condition with the corresponding power density 38.8 ?W cm?3. The experimental results show some discrepancy with the theoretical results due to mechanical loss during impact and the process variations in the beam formation and assembling. The theoretical and experimental results reveal that the proposed configuration has the potential of powering small portable, handheld wireless smart devices from low frequency, specially human motion related vibrations.

Miah A. Halim; Jae Y. Park

2014-01-01T23:59:59.000Z

419

Testing quantum contextuality of continuous-variable states  

SciTech Connect

We investigate the violation of noncontextuality by a class of continuous-variable states, including variations of entangled coherent states and a two-mode continuous superposition of coherent states. We generalize the Kochen-Specker (KS) inequality discussed by Cabello [A. Cabello, Phys. Rev. Lett. 101, 210401 (2008)] by using effective bidimensional observables implemented through physical operations acting on continuous-variable states, in a way similar to an approach to the falsification of Bell-Clauser-Horne-Shimony-Holt inequalities put forward recently. We test for state-independent violation of KS inequalities under variable degrees of state entanglement and mixedness. We then demonstrate theoretically the violation of a KS inequality for any two-mode state by using pseudospin observables and a generalized quasiprobability function.

McKeown, Gerard; Paternostro, Mauro [School of Mathematics and Physics, Queen's University, Belfast, BT7 1NN (United Kingdom); Paris, Matteo G. A. [Dipartimento di Fisica, Universita degli Studi di Milano, I-20133 Milan (Italy); Consorzio Nazionale Italiano di Struttura della Materia, Udr Milano, I-20133 Milan (Italy)

2011-06-15T23:59:59.000Z

420

Implementation of Energy Efficiency Measures and Continuous Commissioning  

NLE Websites -- All DOE Office Websites (Extended Search)

Implementation of Energy Efficiency Measures and Continuous Commissioning Implementation of Energy Efficiency Measures and Continuous Commissioning in Two High-tech Buildings in Silicon Valley Speaker(s): Yaolin Lin Date: September 7, 2010 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Mark Levine Continuous commissioning on existing buildings aims at resolving building mechanical system operation problems, improving system reliability, improving occupants' thermal comfort, increasing building energy efficiency, minimizing retrofit cost, and achieving energy savings at the same time. Dr. Lin will present the implementation of energy efficiency measures on two high-tech buildings in Silicon Valley, California. A total saving of 16,000,000kWh/yr in electricity was achieved and confirmed by measurements from 23 power meters throughout the two buildings. Saving of

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Hierarchical clustering using correlation metric and spatial continuity constraint  

DOE Patents (OSTI)

Large data sets are analyzed by hierarchical clustering using correlation as a similarity measure. This provides results that are superior to those obtained using a Euclidean distance similarity measure. A spatial continuity constraint may be applied in hierarchical clustering analysis of images.

Stork, Christopher L.; Brewer, Luke N.

2012-10-02T23:59:59.000Z

422

Analysis of RHIC beam dump pre-fires  

SciTech Connect

It has been speculated that the beam may cause instability of the RHIC Beam Abort Kickers. In this study, we explore the available data of past beam operations, the device history of key modulator components, and the radiation patterns to examine the correlations. The RHIC beam abort kicker system was designed and built in the 90's. Over last decade, we have made many improvements to bring the RHIC beam abort kicker system to a stable operational state. However, the challenge continues. We present the analysis of the pre-fire, an unrequested discharge of kicker, issues which relates to the RHIC machine safety and operational stability.

Zhang, W.; Ahrens, L.; Fischer, W.; Hahn, H.; Mi, J.; Sandberg, J.; Tan, Y.

2011-03-28T23:59:59.000Z

423

EIS-0238-SA-05: Supplement Analysis | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5: Supplement Analysis 5: Supplement Analysis EIS-0238-SA-05: Supplement Analysis Continued Operation of Los Alamos National Laboratory: Proposed Horizontal Expansion of the Restricted Airspace up to 5,000 feet at Los Alamos National Laboratory The DOE's National Nuclear Security Administration (NNSA) is not proposing to expand the horizontal dimensions of the existing 5,000-foot restricted airspace zone above LANL to include the southeast portion of TA-33 and the eastern portion of TA-54 in response to recent revised threat analyses. Operations at TA-33 and TA-54 would continue to be the same as those that are currently ongoing. Rather, security considerations have changed since the event of 9/11/01 and DOE has identified the need to expand LANL's 5,000-foot restriction to aircraft flights horizontally to include these

424

2011 Annual Workforce Analysis and Staffing Plan Report - NNSA HQ |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2011 Annual Workforce Analysis and Staffing Plan Report - NNSA HQ 2011 Annual Workforce Analysis and Staffing Plan Report - NNSA HQ 2011 Annual Workforce Analysis and Staffing Plan Report - NNSA HQ Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Individual site summaries developed at the end of each year are a basis for DOE Federal Technical Capability Panel reporting to the Secretary of Energy summarizing DOE's federal technical capabilities for defense nuclear facility safety assurance. 2011 Annual Workforce Analysis and Staffing Plan Report - NA-SH

425

2012 Annual Workforce Analysis and Staffing Plan Report - NNSA HQ |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Annual Workforce Analysis and Staffing Plan Report - NNSA HQ Annual Workforce Analysis and Staffing Plan Report - NNSA HQ 2012 Annual Workforce Analysis and Staffing Plan Report - NNSA HQ Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Individual site summaries developed at the end of each year are a basis for DOE Federal Technical Capability Panel reporting to the Secretary of Energy summarizing DOE's federal technical capabilities for defense nuclear facility safety assurance. 2012 Annual Workforce Analysis and Staffing Plan Report - NA-SH

426

PEPCO Comments on Special Environmental Analysis For Actions Taken Under  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

PEPCO Comments on Special Environmental Analysis For Actions Taken PEPCO Comments on Special Environmental Analysis For Actions Taken Under U.S. Department of Energy Emergency Orders Regarding Operation of the Potomac River Generating Station in Alexandria, Virginia PEPCO Comments on Special Environmental Analysis For Actions Taken Under U.S. Department of Energy Emergency Orders Regarding Operation of the Potomac River Generating Station in Alexandria, Virginia Docket No. EO-05-01. Order No. 202-07-02: Potomac Electric Power Company ("Pepco") has reviewed the Special Environmental Analysis ("SEA") referenced above, dated November, 2006, and is providing the following brief comments for your consideration as the Department of Energy ("DOE") continues to evaluate the operating status of the Potomac River

427

Continuous magnetic separator and process  

DOE Patents (OSTI)

A continuous magnetic separator and process for separating a slurry comprising magnetic particles into a clarified stream and a thickened stream. The separator has a container with a slurry inlet, an overflow outlet for the discharge of the clarified slurry stream, and an underflow outlet for the discharge of a thickened slurry stream. Magnetic particles in the slurry are attracted to, and slide down, magnetic rods within the container. The slurry is thus separated into magnetic concentrate and clarified slurry. Flow control means can be used to control the ratio of the rate of magnetic concentrate to the rate of clarified slurry. Feed control means can be used to control the rate of slurry feed to the slurry inlet.

Oder, Robin R. (Export, PA); Jamison, Russell E. (Lower Burrell, PA)

2008-04-22T23:59:59.000Z

428

GARS Operations Newsletter G  

NLE Websites -- All DOE Office Websites (Extended Search)

October, 2011 October, 2011 GARS Operations Newsletter G l o b a l a n d R e g i o n a l S o l u t i o n s D i r e c t o r a t e V OLUME 2 , ISSUE 2 October is National Fire Safety Month Did you know that Fire Prevention Week was established to commemorate the Great Chicago Fire, the tragic 1871 conflagration that killed more than 250 people, left 100,000 homeless, destroyed more than 17,400 structures and burned more than 2,000 acres. The fire began on October 8, but continued into and did most of its damage on October 9, 1871. According to popular legend, the fire broke out after a cow - belonging to Mrs. Catherine O'Leary - kicked over a lamp, setting first the barn, then the whole city on fire. While the Great Chicago Fire was the best-known blaze to start during this fiery two-day stretch,

429

Drilling operations change gear  

SciTech Connect

Predicts that several technological developments (e.g. measurement-while-drilling tools, computer data-gathering systems, improved drill bits, muds, downhole mud motors, and more efficient rigs) will have a major effect on drilling operations in the not-too-distant future. While several companies manufacture MWD systems and most can boast of successful runs, the major problem with the MWD system is cost. Manufacturers continue to make advances in both turbine and positive displacement mud motors. As the life span of downhole mud motors improves, these motors can economically compete with a rotary rig in drilling certain straight-hole intervals. Prototype bit designs include the use of lasers, electronic beams, flames, sparks, explosives, rocket exhaust, chains, projectiles, abrasive jets, and high-pressure erosion. Because drilling fluids are taking a large share of the drilling budget, mud engineers are trying to optimize costs, while maintaining well bore stability and increasing penetration rates. Many companies are taking the strategy of designing the simplest mud program possible and increasing additives only as needed. Air and foam drilling techniques are gaining attention. Concludes that as crude oil prices increase and the rig count begins to rebound, attention will once again turn to drilling technology and methodology.

Moore, S.D.

1982-08-01T23:59:59.000Z

430

Measured Performance and Analysis of Ground Source Heat Pumps for Space Conditioning and for Water Heating in a Low-Energy Test House Operated under Simulated Occupancy Conditions  

SciTech Connect

In this paper we present measured performance and efficiency metrics of Ground Source Heat Pumps (GSHPs) for space conditioning and for water heating connected to a horizontal ground heat exchanger (GHX) loop. The units were installed in a 345m2 (3700ft2) high-efficiency test house built with structural insulated panels (SIPs), operated under simulated occupancy conditions, and located in Oak Ridge, Tennessee (USA) in US Climate Zone 4 . The paper describes distinctive features of the building envelope, ground loop, and equipment, and provides detailed monthly performance of the GSHP system. Space conditioning needs of the house were completely satisfied by a nominal 2-ton (7.0 kW) water-to-air GSHP (WA-GSHP) unit with almost no auxiliary heat usage. Recommendations for further improvement through engineering design changes are identified. The comprehensive set of data and analyses demonstrate the feasibility and practicality of GSHPs in residential applications and their potential to help achieve source energy and greenhouse gas emission reduction targets set under the IECC 2012 Standard.

Ally, Moonis Raza [ORNL] [ORNL; Munk, Jeffrey D [ORNL] [ORNL; Baxter, Van D [ORNL] [ORNL; Gehl, Anthony C [ORNL] [ORNL

2012-01-01T23:59:59.000Z

431

EIS-0380-SA-02: Supplement Analysis | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

-SA-02: Supplement Analysis -SA-02: Supplement Analysis EIS-0380-SA-02: Supplement Analysis Transport and Storage of High-Activity Sealed Sources From Uruguay and Other Locations This supplement analysis (SA) was prepared to assess whether there are substantial changes, or significant new circumstances or information, relevant to environmental concerns associated with continuing the National Nuclear Security Administration's (NNSA's) activities to recover and manage high-activity beta/gamma sealed sources relative to analysis in the Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory, Los Alamos, New Mexico (LANL SWEIS) and other relevant National Environmental Policy Act (NEPA) reviews. This SA analyzes an aspect of the Off-Site Source Recovery Project (OSRP) that was not

432

Continuous wave laser irradiation of explosives  

SciTech Connect

Quantitative measurements of the levels of continuous wave (CW) laser light that can be safely applied to bare explosives during contact operations were obtained at 532 nm, 785 nm, and 1550 nm wavelengths. A thermal camera was used to record the temperature of explosive pressed pellets and single crystals while they were irradiated using a measured laser power and laser spot size. A visible light image of the sample surface was obtained before and after the laser irradiation. Laser irradiation thresholds were obtained for the onset of any visible change to the explosive sample and for the onset of any visible chemical reaction. Deflagration to detonation transitions were not observed using any of these CW laser wavelengths on single crystals or pressed pellets in the unconfined geometry tested. Except for the photochemistry of DAAF, TATB and PBX 9502, all reactions appeared to be thermal using a 532 nm wavelength laser. For a 1550 nm wavelength laser, no photochemistry was evident, but the laser power thresholds for thermal damage in some of the materials were significantly lower than for the 532 nm laser wavelength. No reactions were observed in any of the studied explosives using the available 300 mW laser at 785 nm wavelength. Tables of laser irradiance damage and reaction thresholds are presented for pressed pellets of PBX9501, PBX9502, Composition B, HMX, TATB, RDX, DAAF, PETN, and TNT and single crystals of RDX, HMX, and PETN for each of the laser wavelengths.

McGrane, Shawn D.; Moore, David S.

2010-12-01T23:59:59.000Z

433

Catalyst immobilization techniques for continuous flow synthesis  

E-Print Network (OSTI)

Catalytic processes are ubiquitous in both research and industrial settings. As continuous flow processes continue to gain traction in research labs and fine and pharmaceutical chemical processes, new opportunities exist ...

Nagy, Kevin David

2012-01-01T23:59:59.000Z

434

Systems of Insulation Resistance Continuous Measurement  

Science Journals Connector (OSTI)

In this chapter several methods of continuous measurement of insulation resistance in AC IT systems are described. ... source is explained. Another method of continuous insulation resistance measurement is imposi...

Piotr Olszowiec

2013-01-01T23:59:59.000Z

435

Systems of Insulation Resistance Continuous Measurement  

Science Journals Connector (OSTI)

In this chapter several methods of continuous measurement of insulation resistance in AC IT systems are described. ... source is explained. Another method of continuous insulation resistance measurement is imposi...

Piotr Olszowiec

2014-01-01T23:59:59.000Z

436

JLF Conduct of Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Jupiter Laser Facility (JLF) Conduct Of Operations The Conduct of Operations is a set of procedures and guidelines that are put in place to ensure operational safety and security...

437

Acquisition and Project Management Continuous Improvement Presentation...  

Office of Environmental Management (EM)

Occupational Safety Performance Voluntary Protection Program Onsite Review, Safeguards and Security - August 2012 Report on Acquisition and Project Management Continuous...

438

Analysis  

NLE Websites -- All DOE Office Websites (Extended Search)

Analysis Analysis of Short-Bunch Production with the APS Booster and a Bunch Compressor Michael Borland, AOD/OAG ∗ August 8, 2003 1 Abstract There is significant interest among x-ray scientists in short-pulse x-rays. The x-rays from the APS ring, although very bright, are produced by an electron bunch with an rms length of more than 30 ps. Typically, it is only a linear accelerator that can produce a very short bunch. An idea was brought to my attention by Glenn Decker that might allow us to produce a short bunch using the APS booster. This idea involves extracting the beam from the booster at 3 to 4 GeV, while it is still relatively short, then compressing it with a magnetic bunch compressor. In this note, we present a preliminary analysis of this idea, along with the related idea of using a nonequilibrium beam from the APS photoinjector. 2 Background We will begin with an examination of the ideal result

439

TYPE OF OPERATION  

Office of Legacy Management (LM)

Owner c:ontacted Owner c:ontacted TYPE OF OPERATION ----------------_ jJ Research & Development 0 Production scale testing Cl Pilot Scale 0 Bench Scale Process i Theoretical Studies Sample & Analysis B Production 0 Disposal/Storage $r Prime 0 Subcontract& 0 Purchase Order 0 Facility Type 0 Manufacturing 0 University 0 Research Organization a Other information (i.e., cost + fixed fern, unit price,' time & mate ~r~~-r~~tf~-_~_-_~-~f-~~J~ d ial, etc)_kl/Jlfits ---- -7---- -- Contract/Purchase Order # w?@7-e?-b $ 6, i;,_~~~~~----------------- - ----- C_O!!IF!KXYE-PEELEg: -lTlL-/L?~J --------------------------- OWNERSHXP: AEWHEC AEC/HED' GOVT GB' JT SiXiRACTOR CONiRkCiGR WEE LEAs_EE a!!!%? IEEE!? --------_ ..---LEASED ._ OWNED LANDS BUILDINGS EQUIPMENT

440

TYPE OF OPERATION  

Office of Legacy Management (LM)

3!NEEi_S1 3!NEEi_S1 past: -~~~-~~~~~-~~~---------- current: ------------_------------- Owner contacted q yes g no; if ye=, date contacted TYPE OF OPERATION --~~__--~-~~~---- 5 Research & Development 5 Facility Type 0 Production scale testing c1 Pilot Scale 0 Bench Scale Process z Theareti cal Studi es Sample Sr Analysis 0 Production D Disposal/Storage TYPE OF CONTRACT ---------------- 0 Manufacturing 0 University 0 Research Clrganization B Government Cpanaored Faci 1 i ty 0 Other ~~---~~---_--~~-----_ a Prime 13 Subcontract& D PurcSase Order 0 Other information (i.e., cost + fixed fee, unit price, time & material, +z) ----_----------------------- Cantract/Purchaae Order #-d-z=&-/) -2_7~-------------Is_------------ PERIOD: CONTRACTING I%~(?) - 1465

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Heat Transfer Operators Associated with Quantum Operations  

E-Print Network (OSTI)

Any quantum operation applied on a physical system is performed as a unitary transformation on a larger extended system. If the extension used is a heat bath in thermal equilibrium, the concomitant change in the state of the bath necessarily implies a heat exchange with it. The dependence of the average heat transferred to the bath on the initial state of the system can then be found from the expectation value of a hermitian operator, which is named as the heat transfer operator (HTO). The purpose of this article is the investigation of the relation between the HTOs and the associated quantum operations. Since, any given quantum operation on a system can be realized by different baths and unitaries, many different HTOs are possible for each quantum operation. On the other hand, there are also strong restrictions on the HTOs which arise from the unitarity of the transformations. The most important of these is the Landauer erasure principle. This article is concerned with the question of finding a complete set of restrictions on the HTOs that are associated with a given quantum operation. An answer to this question has been found only for a subset of quantum operations. For erasure operations, these characterizations are equivalent to the generalized Landauer erasure principle. For the case of generic quantum operations however, it appears that the HTOs obey further restrictions which cannot be obtained from the entropic restrictions of the generalized Landauer erasure principle.

Ç. Aksak; S. Turgut

2011-04-14T23:59:59.000Z

442

Spectrum of the volume integral operator of electromagnetic scattering  

E-Print Network (OSTI)

Spectrum of the volume integral operator of the three-dimensional electromagnetic scattering is analyzed. The operator has both continuous essential spectrum, which dominates at lower frequencies, and discrete eigenvalues, which spread out at higher ones. The explicit expression of the operator's symbol provides exact outline of the essential spectrum for any inhomogeneous anisotropic scatterer with Holder continuous constitutive parameters. Geometrical bounds on the location of discrete eigenvalues are derived for various physical scenarios. Numerical experiments demonstrate good agreement between the predicted spectrum of the operator and the eigenvalues of its discretized version.

Neil V. Budko; Alexander B. Samokhin

2005-05-04T23:59:59.000Z

443

Using Whole-Building Electric Load Data in Continuous or Retro-Commissioning  

SciTech Connect

Whole-building electric load data can often reveal problems with building equipment or operations. In this paper, we present methods for analyzing 15-minute-interval electric load data. These methods allow building operators, energy managers, and commissioning agents to better understand a building's electricity consumption over time and to compare it to other buildings, helping them to 'ask the right questions' to discover opportunities for electricity waste elimination, energy efficiency, peak load management, and demand response. For example: Does the building use too much energy at night, or on hot days, or in the early evening? Knowing the answer to questions like these can help with retro-commissioning or continuous commissioning. The methods discussed here can also be used to assess how building energy performance varies with time. Comparing electric load before and after fixing equipment or changing operations can help verify that the fixes have the intended effect on energy consumption. Analysis methods discussed in this paper include: ways to graphically represent electric load data; the definition of various parameters that characterize facility electricity loads; and a regression-based electricity load model that accounts for both time of week and outdoor air temperature. The methods are illustrated by applying them to data from commercial buildings. We demonstrate the ability to recognize changes in building operation, and to quantify changes in energy performance. Some key findings are: 1) Plotting time series electric load data is useful for understanding electricity consumption patterns and changes to those patterns, but results may be misleading if data from different time intervals are not weather-normalized. 2) Parameter plots can highlight key features of electric load data and may be easier to interpret than plots of time series data themselves. 3) A time-of-week indicator variable (as compared to time-of-day and day-of-week indicator variables) improves the accuracy of regression models of electric load. 4) A piecewise linear and continuous outdoor air temperature dependence can be derived without the use of a change-point model (which would add complexity to the modeling algorithm) or assumptions about when structural changes occur (which could introduce inaccuracy). 5) A model that includes time-of-week and temperature dependence can be used for weather normalization and can determine whether the building is unusually temperature-sensitive, which can indicate problems with HVAC operation.

Price, Phillip N.; Mathieu, Johanna L.; Kiliccote, Sila; Piette, Mary Ann

2011-07-01T23:59:59.000Z

444

Continuous cofinal maps on ultrafilters Natasha Dobrinen  

E-Print Network (OSTI)

An ultrafilter U on a countable base has continuous Tukey reductions if when- ever an ultrafilter V is Tukey continuous Tukey reductions is inherited under Tukey reducibility. In particular, if U is Tukey reducible to a p-point then U has continuous Tukey reductions. In the second part, we show that any count- able

Dobrinen, Natasha

445

Analysis of accident sequences and source terms at treatment and storage facilities for waste generated by US Department of Energy waste management operations  

SciTech Connect

This report documents the methodology, computational framework, and results of facility accident analyses performed for the US Department of Energy (DOE) Waste Management Programmatic Environmental Impact Statement (WM PEIS). The accident sequences potentially important to human health risk are specified, their frequencies assessed, and the resultant radiological and chemical source terms evaluated. A personal-computer-based computational framework and database have been developed that provide these results as input to the WM PEIS for the calculation of human health risk impacts. The WM PEIS addresses management of five waste streams in the DOE complex: low-level waste (LLW), hazardous waste (HW), high-level waste (HLW), low-level mixed waste (LLMW), and transuranic waste (TRUW). Currently projected waste generation rates, storage inventories, and treatment process throughputs have been calculated for each of the waste streams. This report summarizes the accident analyses and aggregates the key results for each of the waste streams. Source terms are estimated, and results are presented for each of the major DOE sites and facilities by WM PEIS alternative for each waste stream. Key assumptions in the development of the source terms are identified. The appendices identify the potential atmospheric release of each toxic chemical or radionuclide for each accident scenario studied. They also discuss specific accident analysis data and guidance used or consulted in this report.

Mueller, C.; Nabelssi, B.; Roglans-Ribas, J.; Folga, S.; Policastro, A.; Freeman, W.; Jackson, R.; Mishima, J.; Turner, S.

1996-12-01T23:59:59.000Z

446

Voluntary Protection Program Onsite Review, Tank Farm Operations Contract- November 2010  

Energy.gov (U.S. Department of Energy (DOE))

Evaluation to determine whether the Tank Farm Operations Contract is continuing to perform at a level deserving DOE-VPP Star recognition.

447

Plan for Operating in the Event of a Lapse in Appropriations  

Directives, Delegations, and Requirements

The order established plans and procedures for continuing operations during a lapse in appropriations. Cancels DOE O 137.1A

2011-09-30T23:59:59.000Z

448

Negative-potential operation of TMX-Upgrade  

SciTech Connect

A tandem-mirror configuration can be created by combining hot electron end-cell plasmas with neutral-beam pumping. A region of large negative potential formed in each end cell confines electrons in the central cell. The requirement of charge neutrality causes the central-cell potential to become negative with respect to ground in order to equate ion loss to electron loss. Start-up and formation of the axial potential distribution, neutral-beam pumping, hot electron feed, electron-cyclotron-resonance heating (ECRH) power requirements, and stability are discussed in general terms. Each of these considerations impose constraints on the operation of TMX as a negative machine. The start-up requirements and scenario are also presented. Work on the design and analysis of negative tandems is continuing. The status of work to date is presented here with problem areas for future work identified.

Poulsen, P.; Allen, S.L.; Baldwin, D.E.

1982-04-06T23:59:59.000Z

449

Simulated Energy Savings Comparison Between Two Continuous Commissioning® Methods Applied to a Retrofitted Office Building  

E-Print Network (OSTI)

The 8 th International Conference for Enhanced Building Operations (ICEBO 2008) October 20-22, 2008, Berlin, Germany Simulated Energy Savings Comparison Between Two Continuous Commissioning ? Methods Applied to a Retrofitted Office Building... and the cold and hot 1 ESL-IC-08-10-30 Proceedings of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 The 8 th International Conference for Enhanced Building Operations (ICEBO 2008) October 20...

Texas A& M Campus Building CC® Team

450

2011 Annual Workforce Analysis and Staffing Plan Report - Pacific Northwest  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 Annual Workforce Analysis and Staffing Plan Report - Pacific 1 Annual Workforce Analysis and Staffing Plan Report - Pacific Northwest Site Office 2011 Annual Workforce Analysis and Staffing Plan Report - Pacific Northwest Site Office Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Individual site summaries developed at the end of each year are a basis for DOE Federal Technical Capability Panel reporting to the Secretary of Energy summarizing DOE's federal technical capabilities for defense nuclear facility safety assurance.

451

2012 Annual Workforce Analysis and Staffing Plan Report - Pacific Northwest  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2 Annual Workforce Analysis and Staffing Plan Report - Pacific 2 Annual Workforce Analysis and Staffing Plan Report - Pacific Northwest Site Office 2012 Annual Workforce Analysis and Staffing Plan Report - Pacific Northwest Site Office Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Individual site summaries developed at the end of each year are a basis for DOE Federal Technical Capability Panel reporting to the Secretary of Energy summarizing DOE's federal technical capabilities for defense nuclear facility safety assurance.

452

2010 Annual Workforce Analysis and Staffing Plan Report - Pacific Northwest  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0 Annual Workforce Analysis and Staffing Plan Report - Pacific 0 Annual Workforce Analysis and Staffing Plan Report - Pacific Northwest Site Office 2010 Annual Workforce Analysis and Staffing Plan Report - Pacific Northwest Site Office Managers perform an annual workforce analysis of their organization and develop staffing plans that identify technical capabilities and positions they need to ensure safe operation of defense nuclear facilities. This workforce analysis process continues to cover technical capability needs to address defense nuclear facility and related operational hazards. Individual site summaries developed at the end of each year are a basis for DOE Federal Technical Capability Panel reporting to the Secretary of Energy summarizing DOE's federal technical capabilities for defense nuclear facility safety assurance.

453

Feebates: A Legislative Option to Encourage Continuous Improvements to  

Open Energy Info (EERE)

Feebates: A Legislative Option to Encourage Continuous Improvements to Feebates: A Legislative Option to Encourage Continuous Improvements to Automobile Efficiency Jump to: navigation, search Tool Summary Name: Feebates: A Legislative Option to Encourage Continuous Improvements to Automobile Efficiency Agency/Company /Organization: Rocky Mountain Institute Focus Area: Standards - Incentives - Policies - Regulations Topics: Best Practices Website: www.rmi.org/Knowledge-Center/Library/T08-09_FeebatesLegislativeOption The purpose of this paper is to provide information about feebates. This paper discusses: what a feebate is, why Rocky Mountain Institute (RMI) believes a feebate is a valuable tool, recent analysis that RMI had done on feebates, what the current status of the feebate is, and how the feebate could interact with existing laws.

454

Mission Operations & Data Systems  

E-Print Network (OSTI)

Mission Operations & Data Systems The LASP Mission Operations & Data Systems (MO&DS) group staffs and instruments. Operational software acts like the health systems in a body, ensuring that temperature, energy. The software monitors the health of on-board systems; anything unusual is flagged and sent to mission operators

Mojzsis, Stephen J.

455

ARM - SGP Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Operations Operations SGP Related Links Facilities and Instruments Central Facility Boundary Facility Extended Facility Intermediate Facility Radiometric Calibration Facility Geographic Information ES&H Guidance Statement Operations Science Field Campaigns Visiting the Site Fact Sheet Images Information for Guest Scientists Contacts SGP Operations Routine Operations SGP central facility offices. SGP central facility offices. The overwhelming majority of the measurements with the highest priority, on which the existing experimental designs are based, are regular routine observations, as specified in the ARM Program Plan, 1990 (U.S. Department of Energy 1990). Scientifically and logistically, routine operations also serve as the basis and background for all nonroutine operations, including

456

Guide to good practices for continuing training. [Contains a decision tree for training  

SciTech Connect

The purpose of this Guide to Good Practices for Continuing Training is to provide contractor training organizations with information and methods useful in the development and implementation of a continuing training program. DOE Order 5480.18A, Accreditation of Performance-Based Training for Category A Reactors and Nuclear Facilities,'' and DOE Order 5480.20, Personnel Selection, Qualification and Training Requirements at DOE Reactor and Non-reactor Nuclear Facilities'' Chapter 1, Paragraph 7, require each facility to design and implement a continuing training program. Continuing training is necessary to ensure that facility personnel continually improve their ability to operate and maintain their facility in a safe and reliable manner. Continuing training also should enhance the professionalism of these individuals and should make them aware of the possible consequences of misoperation.

Not Available

1993-02-01T23:59:59.000Z

457

DEVELOPMENT, INSTALLATION AND OPERATION OF THE MPC&A OPERATIONS MONITORING (MOM) SYSTEM AT THE JOINT INSTITUTE FOR NUCLEAR RESEARCH (JINR) DUBNA, RUSSIA  

SciTech Connect

The Material Protection, Control and Accounting (MPC&A) Operations Monitoring (MOM) systems handling at the International Intergovernmental Organization - Joint Institute for Nuclear Research (JINR) is described in this paper. Category I nuclear material (plutonium and uranium) is used in JINR research reactors, facilities and for scientific and research activities. A monitoring system (MOM) was installed at JINR in April 2003. The system design was based on a vulnerability analysis, which took into account the specifics of the Institute. The design and installation of the MOM system was a collaborative effort between JINR, Brookhaven National Laboratory (BNL) and the U.S. Department of Energy (DOE). Financial support was provided by DOE through BNL. The installed MOM system provides facility management with additional assurance that operations involving nuclear material (NM) are correctly followed by the facility personnel. The MOM system also provides additional confidence that the MPC&A systems continue to perform effectively.

Kartashov,V.V.; Pratt,W.; Romanov, Y.A.; Samoilov, V.N.; Shestakov, B.A.; Duncan, C.; Brownell, L.; Carbonaro, J.; White, R.M.; Coffing, J.A.

2009-07-12T23:59:59.000Z

458

Facilities Operations, Planning, and Engineering Services  

E-Print Network (OSTI)

Facilities Operations, Planning, and Design Engineering Services Energy Management & Water and In- house Engineering Mechanical Electrical Engineering Data Analysis Construction Services In Conservation Capital Project-Bldg Systems Review Commissioning BSL3/DLAM Engineer Building Systems Engineering

McLaughlin, Richard M.

459

DOE-ID Operations Summary  

NLE Websites -- All DOE Office Websites (Extended Search)

June 5, 2013 June 5, 2013 DOE-ID Operations Summary For the Period May 16, through May 30, 2013 EDITOR'S NOTE: The following is a summary of contractor operations at the Idaho National Laboratory, managed by DOE- Idaho Operations Office. It has been compiled in response to a request from stakeholders for more information on health, safety and environmental incidents at DOE facilities in Idaho. It also includes a brief summary of accomplishments at the Site. POC - Shannon Brennan, DOE-ID, (208) 526-3993. Advanced Mixed Waste Treatment Project (AMWTP) [No items to Report] Idaho Cleanup Project (ICP) May 15 - 30, 2013: CH2M-WG Idaho, LLC discovered three instances of new information at the Integrated Waste Treatment Unit (IWTU) which have the potential to impact the nuclear safety analysis

460

EIA - AEO2010 - U.S. nuclear power plants: Continued life or replacement  

Gasoline and Diesel Fuel Update (EIA)

U.S. nuclear power plants: continued life or replacement after 60? U.S. nuclear power plants: continued life or replacement after 60? Annual Energy Outlook 2010 with Projections to 2035 U.S. nuclear power plants: Continued life or replacement after 60? Background Nuclear power plants generate approximately 20 percent of U.S. electricity, and the plants in operation today are often seen as attractive assets in the current environment of uncertainty about future fossil fuel prices, high construction costs for new power plants (particularly nuclear plants), and the potential enactment of GHG regulations. Existing nuclear power plants have low fuel costs and relatively high power output. However, there is uncertainty about how long they will be allowed to continue operating. The nuclear industry has expressed strong interest in continuing the operation of existing nuclear facilities, and no particular technical issues have been identified that would impede their continued operation. Recent AEOs had assumed that existing nuclear units would be retired after 60 years of operation (the initial 40-year license plus one 20-year license renewal). Maintaining the same assumption in AEO2010, with the projection horizon extended to 2035, would result in the retirement of more than one-third of existing U.S. nuclear capacity between 2029 and 2035. Given the uncertainty about when existing nuclear capacity actually will be retired, EIA revisited the assumption for the development of AEO2010 and modified it to allow the continued operation of all existing U.S. nuclear power plants through 2035 in the Reference case.

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Continuous Processing of High Thermal Conductivity Polyethylene...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Processing of High Thermal Conductivity Polyethylene Fibers and Sheets Continuous Processing of High Thermal Conductivity Polyethylene Fibers and Sheets Massachusetts Institute of...

462

Theoretical Ecology: Continued growth and success  

E-Print Network (OSTI)

EDITORIAL Theoretical Ecology: Continued growth and successof areas in theoretical ecology. Among the highlights areyear represent theoretical ecology from around the world: 20

Hastings, Alan

2010-01-01T23:59:59.000Z

463

College of Emergency Operations | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emergency Operations Emergency Operations College of Emergency Operations College of Emergency Operations Vision The Emergency Operations Training Academy (EOTA) will be recognized as the model technical training provider for DOE emergency operations personnel, while expanding its customer base to include other designated government and private-sector national and international organizations that require professional training, education, and vocational services. In this expanded role, the Academy will be a vital training asset for DOE and the nation. Roles Provide training analysis, development, and delivery support to the Office of Emergency Operations (NA-40), act in an advisory role in training oriented initiatives, provide access to emergency management/response training throughout the DOE/NNSA complex, support outreach via

464

Supplement Analysis of the 2005 Site-Wide EIS  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

U.S. Department of Energy U.S. Department of Energy National Nuclear Security Administration Livermore Site Office Livermore, California SUPPLEMENT ANALYSIS of the 2005 Final Site-wide Environmental Impact Statement For Continued Operation of Lawrence Livermore National Laboratory Volume I: Main Report AUGUST 2011 DOE/EIS-0348-SA-03 i CONTENTS NOTATION.............................................................................................................................. v SUMMARY...........................................................................................................................S-1 1.0 INTRODUCTION ......................................................................................................... 1-1 1.1 Purpose and Need............................................................................................

465

Qubit-Programmable Operations on Quantum Light Fields  

E-Print Network (OSTI)

Engineering quantum operations is one of the main abilities we need for developing quantum technologies and designing new fundamental tests. Here we propose a scheme for realising a controlled operation acting on a travelling quantum field, whose functioning is determined by an input qubit. This study introduces new concepts and methods in the interface of continuous- and discrete-variable quantum optical systems.

Marco Barbieri; Nicolò Spagnolo; Franck Ferreyrol; Rémi Blandino; Brian J. Smith; Rosa Tualle-Brouri

2014-12-01T23:59:59.000Z

466

National Aeronautics and Space Administration Human Exploration & Operations  

E-Print Network (OSTI)

)/Ground Operations. · Continue strong momentum on Commercial activities. · Conduct remaining launches in LaunchNational Aeronautics and Space Administration Human Exploration & Operations Reorganization Status capabilities to conduct NASA's aeronautics and space activities. 6. Share NASA with the public, educators

Waliser, Duane E.

467

Stability Analysis of Continuous-Time Macroeconometic Systems  

E-Print Network (OSTI)

+ 2 flog(Q #3; e y 4 + P #3; e y 11 ) #0; log(Q #3; + P #3; )#0; #12; 2 y 7 + (#12; 2 #0; #12; 3 )Dy 5 #0; y 1 g (2.15) D 2 y 2 = #0; 3 Dy 2 + 4 #26; 1 #12; 6 log " (Q #3; ) #0;#12; 6 #0; #12; 5 (K #3; ) #0;#12; 6 (Q #3; ) #0;#12; 6 e #0;#12; 6 y 4 #0...; #21; 2 ) + #12; 8 ] #27; (2.17) D 2 y 4 = #0; 7 Dy 4 + 8 #26; log " 1#0; #12; 9 (q #3; p #3; =p #3; i ) #12; 10 e #12; 10 (y 5 +y 14 ) 1#0; #12; 9 (q #3; p #3; =p #3; i ) #12; 10 # + log (C #3; e y 1 + g #3; (Q #3; e y 4 + P #3; e y 11 ) +K #3; e y 3...

Barnett, William A.; He, Yijun

1999-01-01T23:59:59.000Z

468

The simulation and analysis of continuous single product manufacturing systems  

E-Print Network (OSTI)

production un1t in the process. The purpose of the subroutine 1s to relay to the mainline program what the production 1s during the current t1me interval from that particular production unit. The subroutine determines the level of production by using a one... production un1t in the process. The purpose of the subroutine 1s to relay to the mainline program what the production 1s during the current t1me interval from that particular production unit. The subroutine determines the level of production by using a one...

Snyder, Theodore Robert

2012-06-07T23:59:59.000Z

469

First all-sky search for continuous gravitational waves from unknown sources in binary systems  

E-Print Network (OSTI)

We present the first results of an all-sky search for continuous gravitational waves from unknown spinning neutron stars in binary systems using LIGO and Virgo data. Using a specially developed analysis program, the TwoSpect ...

Aggarwal, Nancy

470

A Single Continuous Function as a Model for Fast Rise Exponential Decay Gamma-Ray Bursts.  

E-Print Network (OSTI)

??A quantitative analysis was performed on a sample of Fast-Rise Exponential-Decay gamma-ray bursts using a continuous fitting function. The data were obtained from the Large… (more)

Logue, Daniel B

2006-01-01T23:59:59.000Z

471

Risk Evaluation of Warehouse Operations Using Fuzzy FMEA  

Science Journals Connector (OSTI)

Warehouse processes in supply chain operations contain risks which lead to a poor supply chain performance. Therefore, risk analysis in warehouse operations is a critical issue to increase both the supply chain e...

Alp Ustundag

2012-01-01T23:59:59.000Z

472

CONDUCT OF OPERATIONS (CO)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CONDUCT OF OPERATIONS (CO) CONDUCT OF OPERATIONS (CO) OBJECTIVE TA-55 SST Facility NNSA ORR Implementation Plan 1 1 CO.1 The formality and discipline of operations is adequate to conduct work safely and programs are inplace to maintain this formality and discipline. (Core Requirement 13) Criteria 1. Programmatic elements of conduct of operations are in place for TA-55 SST operations. 2. The TA-55 SST operations personnel adequately demonstrate the principles of conduct ofoperations requirements during the shift performance period. Approach Record Reviews: Review procedures and other facility documents to verify compliance with conduct of operations principles. Interviews: Interview a sampling of the TA-55 SST associated personnel to validate their understanding of the conduct of operations principles (e.g., procedure usage,

473

Cluster States for Continuous-Variable Multipartite Entanglement  

E-Print Network (OSTI)

We introduce a new class of continuous-variable (CV) multipartite entangled states, the CV cluster states, which might be generated from squeezing and kerr-like interaction. The entanglement properties of these states are studied in terms of classical communication and local operations. The quantum teleportation network with cluster states is investigated. The graph states as the general forms of cluster states are presented, which may be used to generate CV Greenberger-Horne-Zeilinger states by simply local measurements and classical communication. A chain for one-dimensional example of cluster states can be readily experimentally produced only with squeezed light and beamsplitters.

Jing Zhang

2005-01-20T23:59:59.000Z

474

Method and apparatus for chemically altering fluids in continuous flow  

DOE Patents (OSTI)

The present invention relates to a continuous flow fluid reactor for chemically altering fluids. The reactor operates on standard frequency (50 to 60 Hz) electricity. The fluid reactor contains particles that are energized by the electricity to form a corona throughout the volume of the reactor and subsequently a non-equilibrium plasma that interacts with the fluid. Particles may form a fixed bed or a fluid bed. Electricity may be provided through electrodes or through an inductive coil. Fluids include gases containing exhaust products and organic fuels requiring oxidation.

Heath, William O. (Richland, WA); Virden, Jr., Judson W. (Richland, WA); Richardson, R. L. (West Richland, WA); Bergsman, Theresa M. (Richland, WA)

1993-01-01T23:59:59.000Z

475

Method and apparatus for chemically altering fluids in continuous flow  

DOE Patents (OSTI)

The present invention relates to a continuous flow fluid reactor for chemically altering fluids. The reactor operates on standard frequency (50 to 60 Hz) electricity. The fluid reactor contains particles that are energized by the electricity to form a corona throughout the volume of the reactor and subsequently a non-equilibrium plasma that interacts with the fluid. Particles may form a fixed bed or a fluid bed. Electricity may be provided through electrodes or through an inductive coil. Fluids include gases containing exhaust products and organic fuels requiring oxidation. 4 figures.

Heath, W.O.; Virden, J.W. Jr.; Richardson, R.L.; Bergsman, T.M.

1993-10-19T23:59:59.000Z

476

BPAT Operational Analysis DSO216 Report  

NLE Websites -- All DOE Office Websites (Extended Search)

as 24, no matter when in the hour the action occurred.) 4709 4626 4543 4709 Installed Wind Capacity (as of the end of each month) Report Created On: 1052012 at 11:15 AM BPAT...

477

MULTISCALE ANALYSIS AND LOCALIZATION OF RANDOM OPERATORS  

E-Print Network (OSTI)

it was observed in light waves in an experiment conducted by Wiersma et al [WiBLR]. Anderson localization

478

Performance Indicators and Analysis of Operations Information  

Directives, Delegations, and Requirements

To identify, monitor, and analyze data that measures the Environment, Safety and Health (ES&H) performance of facilities, programs, and organizations. Cancels DOE 5480.26

1995-09-27T23:59:59.000Z

479

Performance Indicators and Analysis of Operations Information  

Directives, Delegations, and Requirements

To identify, monitor, and analyze data that measures the Environment, Safety and Health (ES&H) performance of facilities, programs, and organization. Cancels DOE 5480.26. Chg 1, 10-26-95.

1995-09-27T23:59:59.000Z

480

Operational analysis of the Port City Stockyards  

E-Print Network (OSTI)

CAs ~ ~ se ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ aes XF; %+~cia FaidXLtim Pgeyl8eal Peel, Q, tg gtediyaHe The Bcm6aes Reedc48 bg PerL CiLP AeehymCN. . . . . . '. . . VXs ~8 Op?SQ4g IS PUFF CiLF SLOCBEp852Sesse ~ ~ ~ ~ s ~ ~ s 5RX%44 RBCOipLSsssee ~ see ~ ~ ss... ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 00 Ibudc of oammiscden Arms bP volume. of bocdnessc Port Cia ShOCCCeyarlep 1951 55 ~ 0 0 ~ 0 ~ ~ 0 ~ 0 ~ ~ ~ ~ ~ 0 ~ 0 0 ~ ~ ~ 0 ~ ~ ~ 0. 0 ~, , Salable receipts of Xivestecgc M Pert City StWgir4sc- bty Pears} 19IhC 550t ~ 0 ~ 0 ~ ~ 00 ~ 00 ~ 0...

Smith, Houston Edward

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "analysis continued operation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Vector Zonal Operations for Spatiotemporal Analysis  

E-Print Network (OSTI)

cubic map algebra to handle raster spatiotemporal data, which turns two-dimensional cells into three- dimensional cubes by adding the time dimension. With spatiotemporal cubes, locations, zones, and neighborhoods can be defined in cubic form (Figure 2...-1). The cubic CM extends raster square cells into cubes. Figure 2-1a illustrates how a local sum function can be performed with two spatiotemporal cubic layers. Here each cube has a values and the result cube will have a new value by adding two cubes together...

Xu, Tingting

2009-12-11T23:59:59.000Z

482

Transforming Commercial Building Operations  

NLE Websites -- All DOE Office Websites (Extended Search)

Transforming Commercial Building Operations Transforming Commercial Building Operations Transforming Commercial Building Operations Ron Underhill Pacific Northwest National Laboratory ronald.underhill@pnnl.gov (509)375-9765 April 4, 2013 2 | Building Technologies Office eere.energy.gov * Most buildings are not commissioned (Cx) before occupancy, including HVAC and lighting systems * Buildings often are poorly operated and maintained leading to significant energy waste of 5 to 20%, even when they have building automation systems (BASs)

483

Transforming Commercial Building Operations  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Transforming Commercial Building Operations Transforming Commercial Building Operations Transforming Commercial Building Operations Ron Underhill Pacific Northwest National Laboratory ronald.underhill@pnnl.gov (509)375-9765 April 4, 2013 2 | Building Technologies Office eere.energy.gov * Most buildings are not commissioned (Cx) before occupancy, including HVAC and lighting systems * Buildings often are poorly operated and maintained leading to significant energy waste of 5 to 20%, even when they have building automation systems (BASs)

484

Quantum Operations and Measurement  

E-Print Network (OSTI)

the Stinespring dilation form of E . 6 #12; II: operator­sum representation E(#) = Tr env # U(## # env )U

Seevinck, Michiel

485

Challenge # 3 ? Operational Issues  

Energy.gov (U.S. Department of Energy (DOE))

Fernando Preto presentation on May 9, 2012, at the Pyrolysis Oil Workshop on Challenge #3 Operational Issues.

486

Operations and maintenance philosophy  

SciTech Connect

This Operations and Maintenance (O&M) Philosophy document is intended to establish a future O&M vision, with an increased focus on minimizing worker exposure, ensuring uninterrupted retrieval operations, and minimizing operation life-cycle cost. It is intended that this document would incorporate O&M lessons learned into on-going and future project upgrades.

DUNCAN, G.P.

1999-10-28T23:59:59.000Z

487

Operating System Resource Management  

E-Print Network (OSTI)

Operating System Resource Management Date: Monday, September 27, 2010 Time: 2:00 ­ 3:00 pm Location allocation and de-allocation by an operating system of processor cores, memory pages, and various types constrained. This talk will propose a scheme for addressing the operating system resource management problem

488

Energy Harvesting Communications with Continuous Energy Arrivals  

E-Print Network (OSTI)

Energy Harvesting Communications with Continuous Energy Arrivals Burak Varan Kaya Tutuncuoglu Aylin--This work considers an energy harvesting transmit- ter that gathers a continuous flow of energy from intermittent sources, thus relaxing the modeling assumption of discrete amounts of harvested energy present

Yener, Aylin

489

CONTINUOUS COFINAL MAPS ON ULTRAFILTERS NATASHA DOBRINEN  

E-Print Network (OSTI)

continuous cofinal maps if whenever an ultrafilter V is Tukey reducible to U, then there is a monotone of supporting continuous cofinal maps is inherited under Tukey reducibility. Second, we show that countable of the first part. Thus, if U is Tukey reducible to a countable iter- ation of Fubini products of p

Dobrinen, Natasha

490

National Security Technology Incubator Operations Plan  

SciTech Connect

This report documents the operations plan for developing the National Security Technology Incubator (NSTI) program for southern New Mexico. The NSTI program will focus on serving businesses with national security technology applications by nurturing them through critical stages of early development. The NSTI program is being developed as part of the National Security Preparedness Project (NSPP), funded by Department of Energy (DOE)/National Nuclear Security Administration (NNSA). The operation plan includes detailed descriptions of the structure and organization, policies and procedures, scope, tactics, and logistics involved in sustainable functioning of the NSTI program. Additionally, the operations plan will provide detailed descriptions of continuous quality assurance measures based on recommended best practices in incubator development by the National Business Incubation Association (NBIA). Forms that assist in operations of NSTI have been drafted and can be found as an attachment to the document.

None

2008-04-30T23:59:59.000Z

491

Long term performance of 137 stack gas continuous emission monitors  

SciTech Connect

Performance data were obtained on 137 monitors representing a total operating time of 1,600,000 hours. The monitors were classified as follows: 74 NO/sub x/, 37 SO/sub 2/, 7 combination NO/sub x//SO/sub 2/, 8 O/sub 2/, and 11 opacity. Results show that data processor failure accounted for 84% of O/sub 2/, 74% of the opacity, and 61% of the combination SO/sub 2//NO/sub x/ continuous emission monitor malfunctions. Each of these three types of moniters had the same average malfunction time (17 hours). Data from one source, a refinery, estimated operation, calibration, and maintenance costs to be $70,000/yr/monitor. (JMT)

Hebert, R.P. (Scott Environmental Tech., Inc., San Bernardino, CA); Mitchell, W.J.

1983-02-01T23:59:59.000Z

492

Hybrid method of deterministic and probabilistic approaches for continuous energy neutron transport problem  

SciTech Connect

This paper presents a new hybrid method of continuous energy Monte Carlo (MC) and multi-group Method of Characteristics (MOC). For a continuous energy neutron transport analysis, the hybrid method employs a continuous energy MC for resonance energy range to treat the resonances accurately and a multi-group MOC for high and low energy ranges for efficiency. Numerical test with a model problem confirms that the hybrid method can produce consistent results with the reference continuous energy MC-only calculation as well as multi-group MOC-only calculation. (authors)

Lee, H.; Lee, D. [Ulsan National Institute of Science and Technology UNIST, gil 50, Eonyang-eup, Ulju-gun, Ulsan, 689-798 (Korea, Republic of)

2013-07-01T23:59:59.000Z

493

Photon number density operator iE^?A^  

Science Journals Connector (OSTI)

A photon number density operator proportional to the dot product of the electric field and the vector potential is introduced as an alternative to the Mandel operator. In the Lorentz gauge it is the time component of the four-vector obtained by contracting the electromagnetic field tensor with the vector potential. Its other components can be interpreted as a current-density vector, and these number and current-density operators satisfy a continuity equation. The photon density operators introduced here are all products of operators that satisfy Maxwell’s equations and whose Lorentz and gauge transformation properties are well known.

M. Hawton and T. Melde

1995-05-01T23:59:59.000Z

494