Sample records for ami advanced metering

  1. Energy Theft in the Advanced Metering Infrastructure

    E-Print Network [OSTI]

    McDaniel, Patrick Drew

    of the smart grid is an advanced metering infrastructure (AMI). AMI replaces the analog meters, but that current AMI devices introduce a myriad of new vectors for achieving it. Key words: AMI, Smart meter currently deployed smart-meters, and attempt to identify root causes of existing vulnerabilities. Theft

  2. E-Print Network 3.0 - advanced metering techniques Sample Search...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    in the Advanced Metering Infrastructure Stephen McLaughlin, Dmitry Podkuiko... of the smart grid is an advanced metering infrastructure (AMI). AMI replaces the analog meters......

  3. Multi-vendor Penetration Testing in the Advanced Metering Infrastructure

    E-Print Network [OSTI]

    McDaniel, Patrick Drew

    Infrastructure (AMI) is changing the way electric energy is produced, priced, and consumed. The introduction,mcdaniel}@cse.psu.edu Abstract - The advanced metering infrastructure (AMI) is revolutionizing electrical grids. Intelligent AMI we develop an archetypal attack tree approach to guide penetration testing across multiple

  4. Efficient and Secure Wireless Communications for Advanced Metering Infrastructure in Smart Grids

    E-Print Network [OSTI]

    Qiu, Robert Caiming

    1 Efficient and Secure Wireless Communications for Advanced Metering Infrastructure in Smart Grids metering infrastructure (AMI) [3] is a key task in smart grid [6] [4]. In such a system, each power user is equipped with a smart meter with the capability of two- way communications, which can monitor the power

  5. Energy Secretary Chu Announces Five Million Smart Meters Installed...

    Office of Environmental Management (EM)

    metering infrastructure (AMI), distribution automation technologies, new electricity pricing programs, and advanced monitoring equipment for the transmission system. The goal...

  6. A Scalable Communication Architecture for Advanced Metering Infrastructure

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    , Communication Architecture, Inter-connecting Overlays. I. INTRODUCTION In AMI system, smart meters measure of data is collected from each smart meter every 15 minutes [Bernaudo et al 2010]. In addition, meter data, the connection from the MDMSs to smart meters following the client-server model as normally to be compatible

  7. Ellsworth Air Force Base Advanced Metering Project

    Broader source: Energy.gov [DOE]

    Presentation covers the Ellsworth Air Force Base Advanced Metering project and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

  8. A Framework for Evaluating Intrusion Detection Architectures in Advanced Metering Infrastructures

    E-Print Network [OSTI]

    Sanders, William H.

    -security Risk Management Process (RMP) tailored to smart grids [2]. In this paper we leverage information from1 A Framework for Evaluating Intrusion Detection Architectures in Advanced Metering Infrastructures] and apply them to the specific case of AMI networks in which asset owners are evaluating the use of an IDS

  9. Assessment of Demand Response and Advanced Metering

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    #12;#12;2008 Assessment of Demand Response and Advanced Metering Staff Report Federal Energy metering penetration and potential peak load reduction from demand response have increased since 2006. Significant activity to promote demand response or to remove barriers to demand response occurred at the state

  10. Second thoughts now on advanced metering

    SciTech Connect (OSTI)

    NONE

    2009-05-15T23:59:59.000Z

    The problem with AMI is that the costs are relatively well-known, but many of the expected benefits are yet to be proven. This is particularly true about the residential sector.

  11. AMI FW UPGRADEABILITY TEST PROCEDURE AND SECURITY ASSESSMENT

    SciTech Connect (OSTI)

    Snyder, Isabelle B [ORNL] [ORNL

    2014-01-01T23:59:59.000Z

    The National Institute of Standards and Technology (NIST) is producing NISTIR 7823 to define test requirements for Smart Meter upgradability. The term Smart Meter refers specifically to advanced electric meters being deployed to enhance management of electricity distribution for residential and industrial consumers. The underlying functional and security requirements for Smart Meter upgradability are specified in NEMA standard SG-AMI 1-2009. The purpose of NISTIR 7823 is to describe conformance test requirements that may be used voluntarily by testers and/or test laboratories to determine whether Smart Meters and Upgrade Management Systems conform to the requirements of NEMA SG-AMI 1-2009.

  12. CSEM WP 105 Dynamic Pricing, Advanced Metering and

    E-Print Network [OSTI]

    California at Berkeley. University of

    CSEM WP 105 Dynamic Pricing, Advanced Metering and Demand Response in Electricity Markets Severin Pricing, Advanced Metering, and Demand Response in Electricity Markets Severin Borenstein Michael Jaske energy crisis and potential solutions for the future. This work was sponsored by the William and Flora

  13. Value creation and value capture of advanced electricity meter information

    E-Print Network [OSTI]

    Oesterlin, Ulf

    2011-01-01T23:59:59.000Z

    Advanced or smart metering has been a hot topic in the electricity community for several years. Despite the excitement about the technology, few business cases are actually able to justify the investment cost. One reason ...

  14. Monitoring Advanced Metering Infrastructures with Amilyzer

    E-Print Network [OSTI]

    Sanders, William H.

    -way communications between smart meters and utility control centers. They are a key component of the smart grid mechanisms are part of communication standards such as the ANSI #12;C12.22. While those protective measures detecting intrusions in IT environments have been developed and evaluated. Through the Trustworthy Cyber

  15. A game theory model for electricity theft detection and privacy-aware control in AMI systems

    E-Print Network [OSTI]

    Cardenas, Alvaro A.

    We introduce a model for the operational costs of an electric distribution utility. The model focuses on two of the new services that are enabled by the Advanced Metering Infrastructure (AMI): (1) the fine-grained anomaly ...

  16. Advanced accelerator simulation research: miniaturizing accelerators from kilometers to meters

    E-Print Network [OSTI]

    Geddes, Cameron Guy Robinson

    Advanced accelerator simulation research: miniaturizing accelerators from kilometers to meters W: Advanced accelerator research is aimed at finding new technologies that can dramatically reduce the size and cost of future high-energy accelerators. Supercomputing is already playing a dramatic and critical role

  17. Meters

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: VegetationEquipment Surfaces andMapping theEnergy StorageAdvancedMetamaterials Researchsc 620 Meters ~

  18. Advanced Metering Infrastructure Security Considerations | Department of

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustionImprovement3-- ------------------------------ChapterJuly 2014 AdvancedEnergy Materials

  19. Designing and Operating Through Compromise: Architectural Analysis of CKMS for the Advanced Metering Infrastructure

    SciTech Connect (OSTI)

    Duren, Mike [Sypris Electronics, LLC] [Sypris Electronics, LLC; Aldridge, Hal [ORNL] [ORNL; Abercrombie, Robert K [ORNL] [ORNL; Sheldon, Frederick T [ORNL] [ORNL

    2013-01-01T23:59:59.000Z

    Compromises attributable to the Advanced Persistent Threat (APT) highlight the necessity for constant vigilance. The APT provides a new perspective on security metrics (e.g., statistics based cyber security) and quantitative risk assessments. We consider design principals and models/tools that provide high assurance for energy delivery systems (EDS) operations regardless of the state of compromise. Cryptographic keys must be securely exchanged, then held and protected on either end of a communications link. This is challenging for a utility with numerous substations that must secure the intelligent electronic devices (IEDs) that may comprise complex control system of systems. For example, distribution and management of keys among the millions of intelligent meters within the Advanced Metering Infrastructure (AMI) is being implemented as part of the National Smart Grid initiative. Without a means for a secure cryptographic key management system (CKMS) no cryptographic solution can be widely deployed to protect the EDS infrastructure from cyber-attack. We consider 1) how security modeling is applied to key management and cyber security concerns on a continuous basis from design through operation, 2) how trusted models and key management architectures greatly impact failure scenarios, and 3) how hardware-enabled trust is a critical element to detecting, surviving, and recovering from attack.

  20. Advanced Metering Implementations - A Perspective from Federal Sector

    SciTech Connect (OSTI)

    Eaarni, Shankar

    2014-08-11T23:59:59.000Z

    Federal mandate (EPACT 2005) requires that federal buildings install advanced electrical meters-meters capable of providing data at least daily and measuring the consumption of electricity at least hourly. This work presents selected advanced metering implementations to understand some of the existing practices related to data capture and to understand how the data is being translated into information and knowledge that can be used to improve building energy and operational performance to meet federal energy reduction mandates. This study highlights case studies to represent some of the various actions that are being taken based on the data that are being collected to improve overall energy performance of these buildings. Some of these actions include- individualized tenant billing and energy forecasting, benchmarking, identifying energy conservation measures, measurement and verification.

  1. The practical equity implications of advanced metering infrastructure

    SciTech Connect (OSTI)

    Felder, Frank A.

    2010-07-15T23:59:59.000Z

    Reductions in advanced metering costs and the efficiency benefits of dynamic pricing make a compelling case to adopt both, particularly for industrial and commercial facilities. Regulators should seriously consider such policies for residential households as well. Regulators can take meaningful steps to mitigate, if not entirely offset, the possibility that some low-income ratepayers may have higher electricity bills with AM and DP. (author)

  2. Unlocking the potential for efficiency and demand response through advanced metering

    E-Print Network [OSTI]

    Levy, Roger; Herter, Karen; Wilson, John

    2004-01-01T23:59:59.000Z

    Advanced Metering, Demand Response, and Dynamic Pricing. Ēfor Efficiency and Demand Response through Advanced Meteringenergy efficiency and demand response programs. Without

  3. Reconciling Security Protection and Monitoring Requirements in Advanced Metering Infrastructures

    E-Print Network [OSTI]

    Sanders, William H.

    , and intrusion detection. In particular, encrypted messages preclude the use of most intrusion detection between the confidentiality requirements for protecting sensitive AMI traffic through encryption, and the monitoring necessary for full inspection of this traffic. The way to reconcile those conflicting requirements

  4. Advanced computational simulation of flow phenomena associated with orifice meters

    SciTech Connect (OSTI)

    Freitas, C.J. [Southwest Research Inst., San Antonio, TX (United States)

    1995-12-31T23:59:59.000Z

    This paper presents and discusses results from a series of computational fluid dynamics (CFD) simulations of fluid flow phenomena associated with orifice meters. These simulations were performed using a new, state-of-the-art CFD code developed at Southwest Research Institute. This code is based on new techniques designed to take advantage of parallel computers to increase computational performance and fidelity of simulation results. This algorithm uses a domain decomposition strategy to create grid systems for very complex geometries composed of simpler geometric subregions, allowing for the accurate representation of the fluid flow domain. The domain decomposition technique maps naturally to parallel computer architectures. Here, the concept of message-passing is used to create a parallel algorithm, using the Parallel Virtual Machine (PVM) library. This code is then used to simulate the flow through an orifice meter run consisting of an orifice with a beta ratio of 0.5 and air flowing at a Reynolds number of 91,100. The work discussed in this paper is but the first step in developing a Virtual Metering Research Facility to support research, analysis, and formulation of new standards for metering.

  5. Security Analysis of Selected AMI Failure Scenarios Using Agent Based Game Theoretic Simulation

    SciTech Connect (OSTI)

    Abercrombie, Robert K [ORNL] [ORNL; Schlicher, Bob G [ORNL] [ORNL; Sheldon, Frederick T [ORNL] [ORNL

    2014-01-01T23:59:59.000Z

    Information security analysis can be performed using game theory implemented in dynamic Agent Based Game Theoretic (ABGT) simulations. Such simulations can be verified with the results from game theory analysis and further used to explore larger scale, real world scenarios involving multiple attackers, defenders, and information assets. We concentrated our analysis on the Advanced Metering Infrastructure (AMI) functional domain which the National Electric Sector Cyber security Organization Resource (NESCOR) working group has currently documented 29 failure scenarios. The strategy for the game was developed by analyzing five electric sector representative failure scenarios contained in the AMI functional domain. From these five selected scenarios, we characterize them into three specific threat categories affecting confidentiality, integrity and availability (CIA). The analysis using our ABGT simulation demonstrates how to model the AMI functional domain using a set of rationalized game theoretic rules decomposed from the failure scenarios in terms of how those scenarios might impact the AMI network with respect to CIA.

  6. Amy Ross

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-Series to someone by E-mail ShareRed Cross Blood DriveoverCarbonAmy Ross Amy

  7. Advanced Metering Plan for Monitoring Energy and Potable Water Use in PNNL EMS4 Buildings

    SciTech Connect (OSTI)

    Pope, Jason E.; Olson, Norman J.; Berman, Marc J.; Schielke, Dale R.

    2011-08-17T23:59:59.000Z

    This updated Advanced Metering Plan for monitoring whole building energy use in Pacific Northwest National Laboratory (PNNL) EMS4 buildings on the PNNL campus has been prepared in accordance with the requirements of the Energy Policy Act of 2005 (EPAct 2005), Section 103, U.S. Department of Energy (DOE) Order 430.2B, and Metering Best Practices, A Guide to Achieving Utility Resource Efficiency, Federal Energy Management Program, October 2007 (Sullivan et al. 2007). The initial PNNL plan was developed in July 2007 (Olson 2007), updated in September 2008 (Olson et al. 2008), updated in September 2009 (Olson et al. 2009), and updated again in August 2010 (Olson et al. 2010).

  8. "Utility Characteristics",,,,,,"Number AMR- Automated Meter Reading",,,,,"Number AMI- Advanced Metering Infrastructure",,,,,"Non AMR/AMI Meters",,,,,"Total Numbers of Meters",,,,,"Energy Served - AMI (MWh)"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ <Information Administration (EIA) 103. Relative Standard Errors for7. Average Prices1.5.Energy

  9. "Utility Characteristics",,,,,,"Number AMR- Automated Meter Reading",,,,,"Number AMI- Advanced Metering Infrastructure",,,,,"Non AMR/AMI Meters1",,,,,"Total Numbers of Meters",,,,,"Energy Served - AMI (MWh)"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ <Information Administration (EIA) 103. Relative Standard Errors for7. Average

  10. "Utility Characteristics",,,,,,"Number AMR- Automated Meter Reading",,,,,"Number AMI- Advanced Metering Infrastructure",,,,,"Energy Served - AMI (MWh)"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ <Information Administration (EIA) 103. Relative Standard Errors for7. Average Prices1.5.Energy Served

  11. Cost benefit analysis for the implementation of smart metering...

    Open Energy Info (EERE)

    Categories: Smart Grid Projects Smart Grid Projects in Europe Smart Grid Projects - Smart Meter and AMI Smart Grid Projects - Home application Smart Grid Projects - Customer...

  12. Microsoft Word - AMI White paper final 013108 _2_.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    on how to use policy to overcome barriers to advanced metering and demand response. * Requirement that all Federal Buildings be equipped with advanced metering. Both...

  13. Ami - The Chemist's Amanuensis

    E-Print Network [OSTI]

    Brooks, Brian; Thorn, Adam; Smith, Matthew; Matthews, Peter; Chen, Shaoming; O'Steen, Ben; Adams, Sam; Townsend, Joseph A; Murray-Rust, Peter

    2011-07-04T23:59:59.000Z

    for chemists to use computers in the lab. The goal was to build a prototype next-generation information assistant ďnatural user interfaceĒ for scientists working at the lab bench. The limitations of paper lab notebooks are well recorded, and the Chemistry... and is already showing huge potential in robotics14. It has enormous potential for Ami; positioning a Kinect in a fume cupboard could give the user new ways to interact with the computer, and help in monitoring the environment. Ami Ė The Chemist...

  14. Long Island Smart Metering Pilot Project

    SciTech Connect (OSTI)

    None

    2012-03-30T23:59:59.000Z

    The Long Island Power Authority (LIPA) Smart Meter Pilots provided invaluable information and experience for future deployments of Advanced Metering Infrastructure (AMI), including the deployment planned as part of LIPA‚??s Smart Grid Demonstration Project (DE-OE0000220). LIPA will incorporate lessons learned from this pilot in future deployments, including lessons relating to equipment performance specifications and testing, as well as equipment deployment and tracking issues. LIPA ultimately deployed three AMI technologies instead of the two that were originally contemplated. This enabled LIPA to evaluate multiple systems in field conditions with a relatively small number of meter installations. LIPA experienced a number of equipment and software issues that it did not anticipate, including issues relating to equipment integration, ability to upgrade firmware and software ‚??over the air‚?Ě (as opposed to physically interacting with every meter), and logistical challenges associated with tracking inventory and upgrade status of deployed meters. In addition to evaluating the technology, LIPA also piloted new Time-of-Use (TOU) rates to assess customer acceptance of time-differentiated pricing and to evaluate whether customers would respond by adjusting their activities from peak to non-peak periods. LIPA developed a marketing program to educate customers who received AMI in the pilot areas and to seek voluntary participation in TOU pricing. LIPA also guaranteed participating customers that, for their initial year on the rates, their electricity costs under the TOU rate would not exceed the amount they would have paid under the flat rates they would otherwise enjoy. 62 residential customers chose to participate in the TOU rates, and every one of them saved money during the first year. 61 of them also elected to stay on the TOU rate ‚?? without the cost guarantee ‚?? at the end of that year. The customer who chose not to continue on the rate was also the one who achieved the greatest savings. However, after the first year, the customer in question installed equipment that would have made TOU rates a more costly option than the residential flat rate. During the second year, all but one customer saved money. That customer increased usage during peak hours, and as a result saw an increase in annual costs (as compared to the flat rate) of $24.17. The results were less clear for commercial customers, which LIPA attributes to rate design issues that it will take into account for future deployments. LIPA views this pilot as a complete success. Not only is LIPA better prepared for a larger deployment of AMI, but it is confident that residential customers will accept AMI and TOU rates and shift their energy consumption from peak to non-peak periods in response to pricing. On a larger scale, this will benefit LIPA and all of its customers by potentially lowering peak demand when energy costs are highest.

  15. The SNL100-02 blade : advanced core material design studies for the Sandia 100-meter blade.

    SciTech Connect (OSTI)

    Griffith, Daniel

    2013-11-01T23:59:59.000Z

    A series of design studies are performed to investigate the effects of advanced core materials and a new core material strategy on blade weight and performance for large blades using the Sandia 100-meter blade designs as a starting point. The initial core material design studies were based on the SNL100-01 100- meter carbon spar design. Advanced core material with improved performance to weight was investigated with the goal to reduce core material content in the design and reduce blade weight. A secondary element of the core study was to evaluate the suitability of core materials from natural, regrowable sources such as balsa and recyclable foam materials. The new core strategy for the SNL100-02 design resulted in a design mass of 59 tons, which is a 20% reduction from the most recent SNL100-01 carbon spar design and over 48% reduction from the initial SNL100-00 all-glass baseline blade. This document provides a description of the final SNL100-02 design, includes a description of the major design modifications, and summarizes the pertinent blade design information. This document is also intended to be a companion document to the distribution of the NuMAD blade model files for SNL100-02 that are made publicly available.

  16. NREL: Biomass Research - Amie Sluiter

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Center in Golden, Colorado. Research Interests Amie Sluiter began research in the biomass-to-ethanol field in 1996. She joined the Biomass Analysis Technologies team to...

  17. Net Metering

    Broader source: Energy.gov [DOE]

    In April 2008, Kentucky enacted legislation that expanded its net metering law by requiring utilities to offer net metering to customers that generate electricity with photovoltaic (PV), wind,...

  18. Net Metering

    Broader source: Energy.gov [DOE]

    NOTE: Kauai Island Electric Cooperative's (KIUC) net metering program has reached its capacity and has implemented a Net Energy Metering Pilot Program.

  19. Failure Impact Analysis of Key Management in AMI Using Cybernomic Situational Assessment (CSA)

    SciTech Connect (OSTI)

    Abercrombie, Robert K [ORNL] [ORNL; Sheldon, Frederick T [ORNL] [ORNL; Hauser, Katie R [ORNL] [ORNL; Lantz, Margaret W [ORNL] [ORNL; Mili, Ali [New Jersey Insitute of Technology] [New Jersey Insitute of Technology

    2013-01-01T23:59:59.000Z

    In earlier work, we presented a computational framework for quantifying the security of a system in terms of the average loss a stakeholder stands to sustain as a result of threats to the system. We named this system, the Cyberspace Security Econometrics System (CSES). In this paper, we refine the framework and apply it to cryptographic key management within the Advanced Metering Infrastructure (AMI) as an example. The stakeholders, requirements, components, and threats are determined. We then populate the matrices with justified values by addressing the AMI at a higher level, rather than trying to consider every piece of hardware and software involved. We accomplish this task by leveraging the recently established NISTR 7628 guideline for smart grid security. This allowed us to choose the stakeholders, requirements, components, and threats realistically. We reviewed the literature and selected an industry technical working group to select three representative threats from a collection of 29 threats. From this subset, we populate the stakes, dependency, and impact matrices, and the threat vector with realistic numbers. Each Stakeholder s Mean Failure Cost is then computed.

  20. AMI Communication Requirements to Implement Demand-Response: Applicability of Hybrid Spread Spectrum Wireless

    SciTech Connect (OSTI)

    Hadley, Mark D.; Clements, Samuel L.; Carroll, Thomas E.

    2011-09-30T23:59:59.000Z

    While holistically defining the smart grid is a challenge, one area of interest is demand-response. In 2009, the Department of Energy announced over $4 billion in grant and project funding for the Smart Grid. A significant amount of this funding was allotted to utilities for cost sharing projects to deploy Smart Grid technologies, many of whom have deployed and are deploying advanced metering infrastructure (AMI). AMI is an enabler to increase the efficiency of utilities and the bulk power grid. The bulk electrical system is unique in that it produces electricity as it is consumed. Most other industries have a delay between generation and consumption. This aspect of the power grid means that there must be enough generation capacity to meet the highest demand whereas other industries could over produce during off-peak times. This requires significant investment in generation capacity to cover the few days a year of peak consumption. Since bulk electrical storage doesn't yet exist at scale another way to curb the need for new peak period generation is through demand-response; that is to incentivize consumers (demand) to curtail (respond) electrical usage during peak periods. Of the various methods proposed for enabling demand-response, this paper will focus on the communication requirements for creating an energy market using transactional controls. More specifically, the paper will focus on the communication requirements needed to send the peak period notices and receive the response back from the consumers.

  1. Net Metering

    Broader source: Energy.gov [DOE]

    The Indiana Utility Regulatory Commission (IURC) adopted rules for net metering in September 2004, requiring the state's investor-owned utilities (IOUs) to offer net metering to all electric...

  2. Net Metering

    Broader source: Energy.gov [DOE]

    In Massachusetts, the state's investor-owned utilities must offer net metering. Municipal utilities are not obligated to offer net metering, but they may do so voluntarily. (There are no electric...

  3. PHY and MAC Layer Design of Hybrid Spread Spectrum Based Smart Meter Network

    SciTech Connect (OSTI)

    Kuruganti, Phani Teja [ORNL] [ORNL

    2012-01-01T23:59:59.000Z

    The smart grid is a combined process of revitalizing the traditional power grid applications and introducing new applications to improve the efficiency of power generation, transmission and distribution. This can be achieved by leveraging advanced communication and networking technologies. Therefore the selection of the appropriate communication technology for different smart grid applications has been debated a lot in the recent past. After comparing different possible technologies, a recent research study has arrived at a conclusion that the 3G cellular technology is the right choice for distribution side smart grid applications like smart metering, advanced distribution automation and demand response management system. In this paper, we argue that the current 3G/4G cellular technologies are not an appropriate choice for smart grid distribution applications and propose a Hybrid Spread Spectrum (HSS) based Advanced Metering Infrastructure (AMI) as one of the alternatives to 3G/4G technologies. We present a preliminary PHY and MAC layer design of a HSS based AMI network and evaluate their performance using matlab and NS2 simulations. Also, we propose a time hierarchical scheme that can significantly reduce the volume of random access traffic generated during blackouts and the delay in power outage reporting.

  4. AMI&SMARTMETERING 48 METERING INTERNATIONAL ISSUE 1 2010

    E-Print Network [OSTI]

    Catholic University of Chile (Universidad Católica de Chile)

    , transmission and distribution of electricity ­ all provided by private companies. The state acts as both their rights and responsibilities. The generation of electricity has been established as a free competition to regulation by the authorities: the price of electricity for distribution companies' regulated clients, i

  5. 2008 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Smart Meters, Rates and the Customer

    E-Print Network [OSTI]

    © 2008 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Smart Meters, OR #12;2 SDG&E Smart Meter Goals · Install AMI/smart metering for all SDG&E electric and gas business're starting to recreate our relationship with customers and transform our company #12;Smart Meter Business

  6. Amy Finkelstein: 2012 John Bates Clark Medalist

    E-Print Network [OSTI]

    Levin, Jonathan

    Amy Finkelstein is the 2012 recipient of the John Bates Clark Medal from the American Economic Association. The core concerns of Amy's research program have been insurance markets and health care. She has addressed whether ...

  7. Metering Approaches

    Broader source: Energy.gov [DOE]

    Metering approaches vary depending on facility design and intended purpose (e.g., administrative offices, laboratory, warehouse, etc.). No one approach fits all applications. In fact, different...

  8. Net Metering

    Broader source: Energy.gov [DOE]

    Net metering is available to customers who generate electricity using solar, wind, hydroelectric, geothermal, biomass, biogas, combined heat and power (CHP) or fuel cell technologies. The ACC has...

  9. Net Metering

    Broader source: Energy.gov [DOE]

    Missouri enacted legislation in June 2007 (S.B. 54)* requiring all electric utilities -- investor-owned utilities, municipal utilities and electric cooperatives -- to offer net metering to...

  10. Net Metering

    Broader source: Energy.gov [DOE]

    New Jersey's net-metering rules apply to all residential, commercial and industrial customers of the state's investor-owned utilities and energy suppliers (and certain competitive municipal...

  11. Net Metering

    Broader source: Energy.gov [DOE]

    Net metering has been available in Oklahoma since 1988 under Oklahoma Corporation Commission (OCC) Order 326195. The OCC's rules require investor-owned utilities and electric cooperatives under...

  12. Net Metering

    Broader source: Energy.gov [DOE]

    Wyoming enacted legislation in February 2001 that established statewide net metering. The law applies to investor-owned utilities, electric cooperatives and irrigation districts. Eligible...

  13. Net Metering

    Broader source: Energy.gov [DOE]

    In October 2009, the Regulatory Commission of Alaska (RCA) approved net metering regulations. These rules were finalized and approved by the lieutenant governor in January 2010 and became...

  14. Net Metering

    Broader source: Energy.gov [DOE]

    '''''NOTE: Legislation enacted in 2011 and 2012 (S.B. 1652, H.B. 3036, and S.B. 3811) has changed several aspects of net metering in Illinois. For customers in competitive classes as of July 1,...

  15. Net Metering

    Broader source: Energy.gov [DOE]

    The North Carolina Utilities Commission (NCUC) requires the stateís three investor-owned utilities -- Duke Energy, Progress Energy and Dominion North Carolina Power -- to make net metering...

  16. Net Metering

    Broader source: Energy.gov [DOE]

    New Hampshire requires all utilities selling electricity in the state to offer net metering to customers who own or operate systems up to one megawatt (1 MW) in capacity that generate electricity...

  17. Net Metering

    Broader source: Energy.gov [DOE]

    Montana's net-metering law, enacted in July 1999, applies to all customers of investor-owned utilities. Systems up to 50 kilowatts (kW) in capacity that generate electricity using solar, wind or...

  18. Net Metering

    Broader source: Energy.gov [DOE]

    Net metering in West Virginia is available to all retail electricity customers. System capacity limits vary depending on the customer type and electric utility type, according to the following...

  19. Net Metering

    Broader source: Energy.gov [DOE]

    California's net-metering law originally took effect in 1996 and applies to all utilities with one exception*. The law has been amended numerous times since its enactment, most recently by AB 327...

  20. Net Metering

    Broader source: Energy.gov [DOE]

    Washington's net-metering law applies to systems up to 100 kilowatts (kW) in capacity that generate electricity using solar, wind, hydro, biogas from animal waste, or combined heat and power...

  1. Net Metering

    Broader source: Energy.gov [DOE]

    In Delaware, net metering is available to any customer that generates electricity using solar, wind or hydro resources, anaerobic digesters, or fuel cells capable of being powered by renewable...

  2. Net Metering

    Broader source: Energy.gov [DOE]

    Note: The program web site listed above links to the Maryland Public Service Commission's Net Metering Working Group page, which contains a variety of information resources related to the ongoing...

  3. Net Metering

    Broader source: Energy.gov [DOE]

    In April 2001, Arkansas enacted legislation (HB 2325) directing the Arkansas Public Service Commission (PSC) to establish net-metering rules for certain renewable-energy systems.* The PSC approved...

  4. Net Metering

    Broader source: Energy.gov [DOE]

    In the District of Columbia (DC), net metering is currently available to residential and commercial customer-generators with systems powered by renewable-energy sources, combined heat and power ...

  5. Net Metering

    Broader source: Energy.gov [DOE]

    The Public Service Commission of Wisconsin (PSC) issued an order on January 26, 1982 requiring all regulated utilities to file tariffs allowing net metering to customers that generate electricity...

  6. Net Metering

    Broader source: Energy.gov [DOE]

    Iowa's statutes do not explicitly authorize the Iowa Utilities Board (IUB) to mandate net metering, but this authority is implicit through the board's enforcement of PURPA and Iowa Code ß 476.41 '...

  7. Net Metering

    Broader source: Energy.gov [DOE]

    North Dakota's net-metering policy, adopted in 1991 by the state Public Service Commission (PSC), applies to renewable-energy systems and combined heat and power (CHP) systems up to 100 kilowatts ...

  8. Net Metering

    Broader source: Energy.gov [DOE]

    Oregon has established separate net-metering programs for the state's primary investor-owned utilities (PGE and PacifiCorp), and for its municipal utilities and electric cooperatives.

  9. Net Metering

    Broader source: Energy.gov [DOE]

    Utah law requires their only investor-owned utility, Rocky Mountain Power (RMP), and most electric cooperatives* to offer net metering to customers who generate electricity using solar energy, wind...

  10. Net Metering

    Broader source: Energy.gov [DOE]

    Net metering is available to all "qualifying facilities" (QFs), as defined by the federal Public Utility Regulatory Policies Act of 1978 (PURPA)*, which pertains to systems up to 80 megawatts (MW)...

  11. Net Metering

    Broader source: Energy.gov [DOE]

    [http://nebraskalegislature.gov/FloorDocs/101/PDF/Final/LB436.pdf LB 436], signed in May 2009, established statewide net metering rules for all electric utilities in Nebraska. The rules apply to...

  12. Net Metering

    Broader source: Energy.gov [DOE]

    '''''Note: H.F. 729, enacted in May 2013, includes many changes to Minnesota's net metering law. These changes are described above, but most will not take effect until rules are implemented at the...

  13. Net Metering

    Broader source: Energy.gov [DOE]

    '''''Note: In March 2011, Virginia enacted HB 1983, which increased the residential net-metering limit to 20 kW. However, residential facilities with a capacity of greater than 10 kW must pay a...

  14. Net Metering

    Broader source: Energy.gov [DOE]

    Connecticut's two investor-owned utilities -- Connecticut Light and Power Company (CL&P) and United Illuminating Company (UI) -- are required to provide net metering to customers that generate...

  15. Net Metering

    Broader source: Energy.gov [DOE]

    '''''The MPSC is reviewing state interconnection and net metering policies in [http://efile.mpsc.state.mi.us/efile/viewcase.php?casenum=15919&submit.x=... Case U-15919].'''''...

  16. Net Metering

    Broader source: Energy.gov [DOE]

    In March 2008, the Florida Public Service Commission (PSC) adopted rules for net metering and interconnection for renewable-energy systems up to two megawatts (MW) in capacity. The PSC rules apply...

  17. Net Metering

    Broader source: Energy.gov [DOE]

    Rhode Island allows net metering for systems up to five megawatts (MW) in capacity that are designed to generate up to 100% of the electricity that a home or other facility uses. Systems that...

  18. Net Metering

    Broader source: Energy.gov [DOE]

    Nevada's original net-metering law for renewable-energy systems was enacted in 1997 and amended in 2001, 2003, 2005 and 2007. Systems up to one megawatt (MW) in capacity that generate electricity...

  19. Net Metering

    Broader source: Energy.gov [DOE]

    [http://www.leg.state.co.us/clics/clics2009a/csl.nsf/fsbillcont3/571064D8... Senate Bill 51] of April 2009 made several changes, effective September 1, 2009, to the state's net metering rules for...

  20. PowerChoice Residential Customer Response to TOU Rates

    E-Print Network [OSTI]

    Peters, Jane S.

    2010-01-01T23:59:59.000Z

    had advanced meters (smart meters) installed. These metersinfrastructure (AMI or Smart Meter) options Ė meters capablecontinue introducing smart meters, amenable to TOU pricing,

  1. Faces of Science: Amy Clarke

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation ProposedUsing ZirconiaPolicy andExsolutionFES6FY 2011 OIG(SC) 2FY98Bauer March 4, 2015Amy

  2. AMIE (ACRF MJO Investigation Experiment)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLasDelivered¬ČPNGExperience4AJ01) (See95TI07)Operations2 Print258 PrintSOLIAMERICA'SnewsFlashAMIE

  3. Saturation meter

    DOE Patents [OSTI]

    Gregurech, S.

    1984-08-01T23:59:59.000Z

    A saturation meter for use in a pressurized water reactor plant comprising a differential pressure transducer having a first and second pressure sensing means and an alarm. The alarm is connected to the transducer and is preset to activate at a level of saturation prior to the formation of a steam void in the reactor vessel.

  4. Technologie Smart metering Technologie Smart metering

    E-Print Network [OSTI]

    Technologie Smart metering Technologie Smart metering 29Bulletin 9/2014 Innovative Dienste mit intelligenten Stromz√§hlern Standby- und K√ľhlger√§teverbrauch aus Smart-Meter-Daten Smart Meter erm√∂glichen weit, kommunikationsf√§higen Stromz√§hlern, fort. Smart Meter erm√∂glichen eine effizi- entere Rechnungsstellung, da sie Mess

  5. TO: ALL STUDENTS FROM: Amy S. Kelso

    E-Print Network [OSTI]

    Howitt, Ivan

    MEMORANDUM TO: ALL STUDENTS FROM: Amy S. Kelso Senior Associate General Counsel DATE: October 5" is legal protection for creative intellectual works, which is broadly interpreted to cover any tangible

  6. Advanced Metering - Using advanced Metering to Improve Building Performance

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergy Cooperation |South ValleyASGovLtr.pdfAboutSheet, April 20142-021FossilJanuaryFacilities

  7. Addressing Energy Demand through Demand Response: International Experiences and Practices

    E-Print Network [OSTI]

    Shen, Bo

    2013-01-01T23:59:59.000Z

    27 Smart Meter and Advanced Metering Infrastructure (AMI)may be insufficient. Most smart meters and their supportingcommon for these new ďsmartĒ meters to read data every half-

  8. Meters Roads N Streams

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: VegetationEquipment Surfaces andMapping theEnergy StorageAdvancedMetamaterials Researchsc 620 Meters ~0

  9. Metering | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    the federal sector has lagged in metering applications. It is not uncommon to find one meter serving hundreds of federal facilities. These master meters make it very difficult to...

  10. Kansas- Net Metering

    Broader source: Energy.gov [DOE]

    Kansas adopted the Net Metering and Easy Connection Act in May 2009 (see K.S.A. 66-1263 through 66-1271), establishing net metering for customers of investor-owned utilities in Kansas. Net metering...

  11. E-Print Network 3.0 - activity meters Sample Search Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Testing in the Advanced Metering Infrastructure Summary: . The activities of a smart meter are coordinated by its Microcontroller Unit (MCU). The majority of work...

  12. "YEAR","MONTH","STATE","UTILITY CODE","UTILITY NAME","NUMBER OF RESIDENTIAL AMR METERS","NUMBER OF COMMERCIAL AMR METERS","NUMBER OF INDUSTRIAL AMR METERS","NUMBER OF TRANSPORTATION AMR METERS","TOTAL NUMBER OF AMR METERS","NUMBER OF RESIDENTIAL AMI METERS","NUMBER OF COMMERCIAL AMI METERS","NUMBER OF INDUSTRIAL AMI METERS","NUMBER OF TRANSPORTATION AMI METERS","TOTAL NUMBER OF AMI METERS","RESIDENTIAL ENERGY SERVED THRU AMI METERS (MWh)","COMMERCIAL ENERGY SERVED THRU AMI METERS (MWh)","INDUSTRIAL ENERGY SERVED THRU AMI METERS (MWh)","TRANSPORTATION ENERGY SERVED THRU AMI METERS (MWh)","TOTAL ENERGY SERVED THRU AMI METERS (MWh)"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ <Information Administration (EIA) 103. Relative Standard Errors for7.

  13. "YEAR","MONTH","STATE","UTILITY CODE","UTILITY NAME","NUMBER OF RESIDENTIAL AMR METERS","NUMBER OF COMMERCIAL AMR METERS","NUMBER OF INDUSTRIAL AMR METERS","NUMBER OF TRANSPORTATION AMR METERS","TOTAL NUMBER OF AMR METERS","NUMBER OF RESIDENTIAL AMI METERS","NUMBER OF COMMERCIAL AMI METERS","NUMBER OF INDUSTRIAL AMI METERS","NUMBER OF TRANSPORTATION AMI METERS","TOTAL NUMBER OF AMI METERS","RESIDENTIAL ENERGY SERVED THRU AMI METERS (MWh)","COMMERCIAL ENERGY SERVED THRU AMI METERS (MWh)","INDUSTRIAL ENERGY SERVED THRU AMI METERS (MWh)","TRANSPORTATION ENERGY SERVED THRU AMI METERS (MWh)","TOTAL ENERGY SERVED THRU AMI METERS (MWh)"

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ <Information Administration (EIA) 103. Relative Standard Errors

  14. AMIS Training Material 1 Institutional Research and Planning October 2012

    E-Print Network [OSTI]

    Farritor, Shane

    AMIS Training Material 1 Institutional Research and Planning October 2012 University of Nebraska Panel" #12;AMIS Training Material 2 Institutional Research and Planning October 2012 University of Nebraska-Lincoln Page 2 of 9 Change View by: "Category" to "Small Icons" #12;AMIS Training Material 3

  15. SMOOTH ERGODIC THEORY AMIE WILKINSON

    E-Print Network [OSTI]

    Wilkinson, Amie

    is ergodic. The argument relies on the Ergodic Theorem for invertible transformations, the density of continuous functions among integrable functions, and the existence of stable and unstable foliations their founda- tional ergodic theorems. The study of ergodic properties of smooth systems saw an advance

  16. SMOOTH ERGODIC THEORY AMIE WILKINSON

    E-Print Network [OSTI]

    Wilkinson, Amie

    is ergodic. The argument relies on the Ergodic Theorem for invertible transformations, the density of continuous functions among integrable functions, and the existence of stable and unstable foliations of smooth systems saw an advance in the work of Hadamard and E. Hopf in the 1930's their study of geodesic

  17. Capacity Analysis of a Wireless Backhaul for Metering in the Smart Grid

    E-Print Network [OSTI]

    Namboodiri, Vinod

    in the maintenance of the supply-demand balance around the clock and the resulting reliability improvement. By improving the communication infrastructure, a vital ingredient for the Smart Grid, a more reliable approach. With the introduction of AMI technology, two-way communication between a smart meter (SM) and the control center

  18. Net Metering Rules (Arkansas)

    Broader source: Energy.gov [DOE]

    The Net Metering Rules are promulgated under the authority of the Arkansas Public Service Commission. These rules are created to establish rules for net energy metering and interconnection. These...

  19. Propeller Flow Meter

    E-Print Network [OSTI]

    Enciso, Juan; Santistevan, Dean; Hla, Aung K.

    2007-10-01T23:59:59.000Z

    Propeller flow meters are commonly used to measure water flow rate. They can also be used to estimate irrigation water use. This publication explains how to select, install, read and maintain propeller flow meters....

  20. Progress Energy- Net Metering

    Broader source: Energy.gov [DOE]

    In August 2009, the South Carolina Public Service Commission issued an order mandating net metering be made available by the regulated electric utilities; the order incorporates a net metering...

  1. SRP- Net Metering

    Broader source: Energy.gov [DOE]

    Salt River Project (SRP) modified an existing net-metering program for residential and commercial customers in November 2013. Net metering is now available to customers who generate electricity...

  2. LADWP- Net Metering (California)

    Broader source: Energy.gov [DOE]

    LADWP allows its customers to net meter their photovoltaic (PV), wind, and hybrid systems with a capacity of not more than one megawatt. LADWP will provide the necessary metering equipment unless...

  3. Utility Metering- AGL Resources

    Broader source: Energy.gov [DOE]

    Presentationógiven at the Spring 2013 Federal Utility Partnership Working Group (FUPWG) meetingódiscusses AGL Resources metering, including interruptible rate customers, large users, and meeting federal metering goals.

  4. Economics of Energy Metering

    E-Print Network [OSTI]

    Duncan, J. D.

    1979-01-01T23:59:59.000Z

    history of industrial usage and their mechanical simplicity. The Flow Technology Group divided orifice meters into three basic types -- Class A, B, and C. Class A meters are the ultimate current technology can provide. Their overall accuracy is ~l... cost for a Class A orifice is $45,000, excluding the computer cost. Class B meters have an accuracy of +2%. The transmitter analog outputs are usually recorded on charts. These meters are used for utilities accounting and non critical production...

  5. AmiGO: online access to ontology and annotation data

    SciTech Connect (OSTI)

    Carbon, Seth; Ireland, Amelia; Mungall, Christopher J.; Shu, ShengQiang; Marshall, Brad; Lewis, Suzanna

    2009-01-15T23:59:59.000Z

    AmiGO is a web application that allows users to query, browse, and visualize ontologies and related gene product annotation (association) data. AmiGO can be used online at the Gene Ontology (GO) website to access the data provided by the GO Consortium; it can also be downloaded and installed to browse local ontologies and annotations. AmiGO is free open source software developed and maintained by the GO Consortium.

  6. Amy B. Demagistris | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehiclesTankless orA BRIEF HISTORYAgencyLocal CommunityEnergyAmy B.

  7. ARM - ARM MJO Investigation Experiment (AMIE)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert SouthwestTechnologies |NovemberARMContactsARM Engineering and Related Links amie.png

  8. AMI (Smart Grid Project) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160 East 300 SouthWater Rights,InformationWind Energy Jump to: navigation,AMI (Smart

  9. Metering and the New Federal Requirements of Energy Policy Act 2005

    E-Print Network [OSTI]

    Ream, A.; Verdict, M.

    2006-01-01T23:59:59.000Z

    agencies to meter electricity use in all federal buildings by Oct. 1, 2012 using advanced meters or metering devices that provide data at least daily. Six months after the enactment of EPAct, DOEís Federal Energy Management Program, or FEMP... Station, Texas ABSTRACT Section 103 of the Energy Policy Act of 2005 (EPAct 2005) (1) mandates the installation of meters and advanced electric meters on all Federal Buildings by 2012 using guidelines developed by the US Department of Energy...

  10. AMIS-Training Material iReport Training Part 2

    E-Print Network [OSTI]

    Farritor, Shane

    AMIS- Training Material iReport Training ­Part 2 (iReport-3.0.0) Topic: Parameters · Open a report- Training Material · Open the `Document structure' Page 2 of 7 6/27/2008 Institutional Research and Planning University of Nebraska-Lincoln #12;AMIS- Training Material · Right click on `Parameters' > Add > Parameter

  11. E-Print Network 3.0 - amy trigger system Sample Search Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    -installed operating system and software license agreement screens When an AMI instance boots for the first time... Industry Application Platform AMI you can begin using the...

  12. Net Metering Webinar

    Broader source: Energy.gov [DOE]

    Part of the Tribal Renewable Energy Webinar Series, this webinar will focus on the services provided by utility net metering and their importance in making projects cost effective.

  13. Energy Metering Audit Procedure

    E-Print Network [OSTI]

    Whitaker, W. S.

    Energy Meterilg Audtt Procedure Wiliam S Whitaker Engineering Specialist T X E INC. laPorte Texas INTROOUCI'ION This paper describes the recent audit of the utility distriooticn meters in a petrochanica1 plant. These meters measure the steam..., cx:ndensate, natural gas, water, nitrogen and air flCMS to the different process units within the plant. This audit started as an attellPt to resolve discrepan::ies between the 650 PSIG steam distriootion and supply meters. Theoretically the sum...

  14. DC attenuation meter

    DOE Patents [OSTI]

    Hargrove, Douglas L.

    2004-09-14T23:59:59.000Z

    A portable, hand-held meter used to measure direct current (DC) attenuation in low impedance electrical signal cables and signal attenuators. A DC voltage is applied to the signal input of the cable and feedback to the control circuit through the signal cable and attenuators. The control circuit adjusts the applied voltage to the cable until the feedback voltage equals the reference voltage. The "units" of applied voltage required at the cable input is the system attenuation value of the cable and attenuators, which makes this meter unique. The meter may be used to calibrate data signal cables, attenuators, and cable-attenuator assemblies.

  15. Meter Expansion Plan Existing Multi-Space Meter

    E-Print Network [OSTI]

    Duchowski, Andrew T.

    Meter Expansion Plan 11 35 9 7 10 20 12 11 12 46 23 15 15 60 23 Existing Multi-Space Meter Split Regulations 136 New Multi-Space Meter Visitor Only New Multi-Space Meter Split Regulations KEY 97 Updated 7/8/13 11 5 #12;HAVE.HAVE. UNION DR. 1 2 3 4 5 New Multi-space Meter After: 5 Meter Spaces Regulations

  16. Net Metering Resources

    Broader source: Energy.gov [DOE]

    State net metering policies allow customers to produce onsite electricity and sell excess generation to the utility at a set price, which creates an incentive for private investment in distributed...

  17. Guam- Net Metering

    Broader source: Energy.gov [DOE]

    Guam's Public Utilities Commission (PUC) reviewed net metering and interconnection during a regular meeting in February 2009 (Docket 08-10). Please contact the [http://www.guampuc.com/ Guam PUC]...

  18. Avista Utilities- Net Metering

    Broader source: Energy.gov [DOE]

    Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has developed a net...

  19. WOOD STREET METERED LOT

    E-Print Network [OSTI]

    Dai, Yang

    LOT E1 LOT O WOOD STREET METERED LOT LOT W5 LOT C4 LOT B4 LOT L LOT M MARSHFIELDAVENUE PAULINASTREET Clinical Sciences Building UI Hospital Wood Street Station Clinical Sciences North Grand Grounds Garden

  20. Ashland Electric- Net Metering

    Broader source: Energy.gov [DOE]

    In 1996, Ashland adopted a net-metering program that includes simple interconnection guidelines. The program encourages the adoption of renewable-energy systems by committing the city to purchase,...

  1. Idaho Power- Net Metering

    Broader source: Energy.gov [DOE]

    Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has developed a net...

  2. Puerto Rico- Net Metering

    Broader source: Energy.gov [DOE]

    Puerto Rico enacted net-metering legislation in August 2007, allowing customers of Puerto Rico Electric Power Authority (PREPA) to use electricity generated by solar, wind or "other" renewable...

  3. Net Metering (Ontario, Canada)

    Broader source: Energy.gov [DOE]

    Ontario's net metering regulation allows you to send electricity generated from renewable sources to the electrical grid for a credit toward your energy costs. Here's how it works. Your utility...

  4. West Virginia Property Tax Briefing Paper Amy Higginbotham

    E-Print Network [OSTI]

    Mohaghegh, Shahab

    West Virginia Property Tax Briefing Paper By Amy Higginbotham Arzu Sen Dr. Tami Gurley-Calvez Bureau of Business and Economic Research College of Business and Economics West Virginia University 2009 ...........................................................................................................................1 History of the West Virginia Property Tax

  5. Washington City Power- Net Metering

    Broader source: Energy.gov [DOE]

    Washington City adopted a net-metering program, including interconnection procedures, in January 2008.* Net metering is available to residential and commercial customers that generate electricity...

  6. Neutron dose equivalent meter

    DOE Patents [OSTI]

    Olsher, Richard H. (Los Alamos, NM); Hsu, Hsiao-Hua (Los Alamos, NM); Casson, William H. (Los Alamos, NM); Vasilik, Dennis G. (Los Alamos, NM); Kleck, Jeffrey H. (Menlo Park, CA); Beverding, Anthony (Foster City, CA)

    1996-01-01T23:59:59.000Z

    A neutron dose equivalent detector for measuring neutron dose capable of accurately responding to neutron energies according to published fluence to dose curves. The neutron dose equivalent meter has an inner sphere of polyethylene, with a middle shell overlying the inner sphere, the middle shell comprising RTV.RTM. silicone (organosiloxane) loaded with boron. An outer shell overlies the middle shell and comprises polyethylene loaded with tungsten. The neutron dose equivalent meter defines a channel through the outer shell, the middle shell, and the inner sphere for accepting a neutron counter tube. The outer shell is loaded with tungsten to provide neutron generation, increasing the neutron dose equivalent meter's response sensitivity above 8 MeV.

  7. Efficient Metering Schemes with Pricing

    E-Print Network [OSTI]

    Stinson, Douglas

    Efficient Metering Schemes with Pricing Barbara Masucci Dipartimento di Informatica ed Applicazioni and Pinkas [7] introduced metering schemes. They proposed metering schemes in which any server is able and proposed metering schemes with pricing. In their schemes any server is able to construct a proof which

  8. E-Print Network 3.0 - automatic watering based Sample Search...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    a central receiving point via a fixed base... agencies, water utilities, AMR, automatic meter reading, AMI, advanced metering infrastructure, smart... on a 15minute interval...

  9. CX-002832: Categorical Exclusion Determination | Department of...

    Broader source: Energy.gov (indexed) [DOE]

    and Kalispell by extendingexpanding the existing AMI (advanced metering infrastructure (smart meter)) system. DOCUMENT(S) AVAILABLE FOR DOWNLOAD CX-002832.pdf More Documents &...

  10. 2010 U.S. Smart Grid Vendor Ecosystem Report on the companies...

    Broader source: Energy.gov (indexed) [DOE]

    Smart Grid vendor ecosystem is an increasingly interdependent web of companies. Vendors of Advanced Metering Infrastructure (AMI) products (meters, communication units, and related...

  11. Outage Detection in Power Distribution Networks with Optimally-Deployed Power Flow Sensors

    E-Print Network [OSTI]

    Zhao, Yue

    . When two-way communications from the operator and the smart meters are available, AMI polling has been deployed real-time power flow sensors and that of load estimates via Advanced Metering Infrastructure (AMI

  12. Duke Energy- Net Metering

    Broader source: Energy.gov [DOE]

    In August 2009, the South Carolina Public Service Commission issued an [http://dms.psc.sc.gov/pdf/matters/F05030FC-E19A-9225-B838F72EDF4557DC.pdf] order mandating net metering be made available by...

  13. Elbow mass flow meter

    DOE Patents [OSTI]

    McFarland, Andrew R. (College Station, TX); Rodgers, John C. (Santa Fe, NM); Ortiz, Carlos A. (Bryan, TX); Nelson, David C. (Santa Fe, NM)

    1994-01-01T23:59:59.000Z

    Elbow mass flow meter. The present invention includes a combination of an elbow pressure drop generator and a shunt-type mass flow sensor for providing an output which gives the mass flow rate of a gas that is nearly independent of the density of the gas. For air, the output is also approximately independent of humidity.

  14. Abstract--A methodology to evaluate the installation of new electricity metering technologies in a developing country is

    E-Print Network [OSTI]

    Dixon, Juan

    customer database, identifying a particular urban zone in which, under certain assumptions, smart metering. Although smart metering would provide benefits to all society, customers originating these benefits would only perceive a small part of them. Index Terms-- Demand Response, Advanced Metering, Smart Meters

  15. DRAFT NISTIR 7823 Advanced Metering Infrastructure

    E-Print Network [OSTI]

    to Jim Foti, Nelson Hastings, and Marianne Swanson of NIST, Victoria Pillitteri of Booz Allen Hamilton

  16. Flow metering valve

    DOE Patents [OSTI]

    Blaedel, Kenneth L. (Dublin, CA)

    1985-01-01T23:59:59.000Z

    An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

  17. Flow metering valve

    DOE Patents [OSTI]

    Blaedel, K.L.

    1983-11-03T23:59:59.000Z

    An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

  18. Michael Van Vliet and Amy Todd, `02 Santo Domingo, Dominican Republic

    E-Print Network [OSTI]

    Michael Van Vliet and Amy Todd, `02 Santo Domingo, Dominican Republic In July of 2001, Amy Todd in the capitol of the Dominican Republic, Santo Domingo, we were immediately overcome and shocked by the poverty

  19. Montana Electric Cooperatives- Net Metering

    Broader source: Energy.gov [DOE]

    The Montana Electric Cooperatives' Association (MECA) adopted model interconnection guidelines in 2001 and a revised net-metering policy in September 2008. Net metering is available in whole or...

  20. Rocky Mountain Power- Net Metering

    Broader source: Energy.gov [DOE]

    Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has a net-metering...

  1. SCE&G- Net Metering

    Broader source: Energy.gov [DOE]

    In August 2009, the South Carolina Public Service Commission issued an order mandating net metering be made available by the regulated electric utilities; the order incorporates a net metering...

  2. Dimensionality of the USDA Food Security Index Amy G. Froelich

    E-Print Network [OSTI]

    Froelich, Amy G.

    Dimensionality of the USDA Food Security Index Amy G. Froelich Helen H. Jensen Iowa State University DRAFT: November 21, 2002 Report prepared under USDA Economic Research Service cooperative the first Food Security Supplement (Module) designed to measure the amount of food insecurity and hunger

  3. Cubic Lithium Nitride Amy Lazicki1,2

    E-Print Network [OSTI]

    Islam, M. Saif

    Cubic Lithium Nitride to 200 GPa Amy Lazicki1,2 Choong-Shik Yoo1, Warren Pickett2, Richard electrolyte material for lithium-based batteries ∑ possible hydrogen storage material Thrust of this research ≠ differences between the XRS and PDOS are indications of the presence of core-hole interactions (excitons

  4. TO: ALL UNIVERSITY FACULTY AND STAFF FROM: Amy S. Kelso,

    E-Print Network [OSTI]

    Howitt, Ivan

    MEMORANDUM TO: ALL UNIVERSITY FACULTY AND STAFF FROM: Amy S. Kelso, Senior Associate General Counsel DATE: October 5, 2012 SUBJECT: Copyright Infringement Reminder Digital file sharing technology has works, which is broadly interpreted to cover any tangible expression of an idea. Text (including email

  5. Berkeley Emeriti Amy Block Joy, Ph.D.

    E-Print Network [OSTI]

    Alvarez-Cohen, Lisa

    ; journal articles and books follow. Amy Block Joy, PhD, has authored plenty of material as an academic The Faculty Club It is not unusual for academics to author books; in fact, it's expected. Conduct the research. Dr. Joy's academic roots are in Berkeley. She received her BA in Biochemistry and Bacteriology (with

  6. Portable wastewater flow meter

    DOE Patents [OSTI]

    Hunter, Robert M. (320 S. Wilson Ave., Bozeman, MT 59715)

    1999-02-02T23:59:59.000Z

    A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under fill pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

  7. Portable wastewater flow meter

    DOE Patents [OSTI]

    Hunter, Robert M. (320 S. Wilson Ave., Bozeman, MT 59715)

    1990-01-01T23:59:59.000Z

    A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under full pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

  8. Reports on Initial Results of Smart Grid Investment Grant Projects...

    Energy Savers [EERE]

    and time-based rates; adding advanced voltage and volt-ampere reactive (VAR) optimization (VVO) technologies; and installing advanced metering infrastructure (AMI). For more...

  9. City of Brenham- Net Metering

    Broader source: Energy.gov [DOE]

    In September 2010, the City of Brenham passed an ordinance adopting net metering and interconnection procedures. Customer generators up to 10 megawatts (MW) are eligible to participate, although...

  10. O&M Metering Guidance

    Broader source: Energy.gov (indexed) [DOE]

    URL links, and references - Improved document "readability" - Added information regarding water 4 | FEDERAL ENERGY MANAGEMENT PROGRAM femp.energy.gov O&M and Metering Guidance...

  11. Net Metering (New Brunswick, Canada)

    Broader source: Energy.gov [DOE]

    The NB Power Net Metering program provides customers with the option to connect their own environmentally sustainable generation unit to NB Power's distribution system. The program allows customers...

  12. advanced reprocessing system: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Zoran 40 An Overview on Advance Metering System CiteSeer Summary: Abstract The term "Smart meter " typically refers to an electrical meter, but the term is also starting to be...

  13. 2,279 METERS BOUYANT POLYOLEFIN MOORING LINE

    E-Print Network [OSTI]

    2,279 METERS BOUYANT POLYOLEFIN MOORING LINE 4,900 METERS NYLON LINE, CONTINUOUS 700 METERS KEO 1: DATE: DATE: MOORING: SCOPE: NOAA-PMEL-KE 1.4:1 TC5 METERS 700 METERS WIRE ROPE FAIRING TO 500 METERS TC10 METERS 50 METERS 25 METERS TC TC 75 METERS TC 100 METERS TP 150 METERS TC 200 METERS TC 300 METERS

  14. Wavelength meter having elliptical wedge

    DOE Patents [OSTI]

    Hackel, Richard P. (Livermore, CA); Feldman, Mark (Livermore, CA)

    1992-01-01T23:59:59.000Z

    A wavelength meter is disclosed which can determine the wavelength of a laser beam from a laser source within an accuracy range of two parts in 10.sup.8. The wavelength meter has wedge having an elliptically shaped face to the optical path of the laser source and includes interferometer plates which form a vacuum housing.

  15. Wavelength meter having elliptical wedge

    DOE Patents [OSTI]

    Hackel, R.P.; Feldman, M.

    1992-12-01T23:59:59.000Z

    A wavelength meter is disclosed which can determine the wavelength of a laser beam from a laser source within an accuracy range of two parts in 10[sup 8]. The wavelength meter has wedge having an elliptically shaped face to the optical path of the laser source and includes interferometer plates which form a vacuum housing. 7 figs.

  16. Gerson Recinos Onramp Metering System

    E-Print Network [OSTI]

    Kachroo, Pushkin

    Gerson Recinos Onramp Metering System Using Arduino and Processing Overview­ For this project I built an Onramp Metering System using Arduino and Processing. The Microcontroller used was Arduino (based on Atmel168) and the programming languages were Processing and Wiring (derivative

  17. Impact of orifice metering uncertainties

    SciTech Connect (OSTI)

    Stuart, J.W. (Pacific Gas and Electric Co., San Francisco, CA (USA))

    1990-12-01T23:59:59.000Z

    In a recent utility study, attributed 38% of its unaccounted-for UAF gas to orifice metering uncertainty biasing caused by straightening vanes. How this was determined and how this applied to the company's orifice meters is described. Almost all (97%) of the company's UAF gas was found to be attributed to identifiable accounting procedures, measurement problems, theft and leakage.

  18. Microsoft PowerPoint - 6_AMY_JOHNSON_MMSS 2014 AJohnson UUSA...

    National Nuclear Security Administration (NNSA)

    Lessons Learned Associated with Obtaining License for a New Enrichment Plant Amy Johnson, URENCO USA URENCO USA History June to June - Combined License (COL) approval to production...

  19. Advances

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD)ProductssondeadjustsondeadjustAbout the BuildingInnovation PortalScienceScripting forAdvances in

  20. Valley Electric Association- Net Metering

    Broader source: Energy.gov [DOE]

    The Board of Directors for Valley Electric Association (VEA) approved net metering in April 2008. The rules apply to systems up to 30 kW, though owners of larger systems may be able to negotiate...

  1. Grays Harbor PUD- Net Metering

    Broader source: Energy.gov [DOE]

    Grays Harbor PUD's net-metering program differs slightly from what is required by Washington state law in that Grays Harbor PUD reimburses customers for net excess generation (NEG), at the end of...

  2. Austin Energy- Net Metering (Texas)

    Broader source: Energy.gov [DOE]

    Austin Energy, the municipal utility of Austin Texas, offers net metering for renewable energy systems up to 20 kilowatts (kW) to its non-residential retail electricity customers. The definition of...

  3. Electric Metering | Department of Energy

    Office of Environmental Management (EM)

    has installed meters in the James Forrestal Building that will enable DOE to measure electricity use and costs in its headquarters facility. You may explore this data further by...

  4. START USING THE NEW ONLINE METER

    E-Print Network [OSTI]

    Singh, Jaswinder Pal

    START USING THE NEW ONLINE METER REQUEST FORM TOOL CAS login Logging in with your Princeton Net and convenient way for departments to send outgoing metered mail with Mail Services! The new Online Meter Request

  5. Healthcare Energy Metering Guidance (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2011-07-01T23:59:59.000Z

    This brochure is intended to help facility and energy managers plan and prioritize investments in energy metering. It offers healthcare-specific examples of metering applications, benefits, and steps that other health systems can reproduce. It reflects collaborative input from the U.S. Department of Energy national laboratories and the health system members of the DOE Hospital Energy Alliance's Benchmarking and Measurement Project Team.

  6. Gamma radiation field intensity meter

    DOE Patents [OSTI]

    Thacker, L.H.

    1995-10-17T23:59:59.000Z

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode. 4 figs.

  7. Gamma radiation field intensity meter

    DOE Patents [OSTI]

    Thacker, L.H.

    1994-08-16T23:59:59.000Z

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode. 4 figs.

  8. Gamma radiation field intensity meter

    DOE Patents [OSTI]

    Thacker, Louis H. (Knoxville, TN)

    1995-01-01T23:59:59.000Z

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode.

  9. Gamma radiation field intensity meter

    DOE Patents [OSTI]

    Thacker, Louis H. (Knoxville, TN)

    1994-01-01T23:59:59.000Z

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode.

  10. AMIS (Smart Grid Project) (Traun, Austria) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160 East 300 SouthWater Rights,InformationWind Energy Jump to: navigation,AMI

  11. Amy LaFountain | Photosynthetic Antenna Research Center

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD)ProductssondeadjustsondeadjustAbout theOFFICEAmes Laboratory Site Sustainability PlanFalconAmmarofAmy

  12. DVS5.2 METERS 8 METERS OCR507, STOR-X DATA LOGGER

    E-Print Network [OSTI]

    DVS5.2 METERS 10 METERS 8 METERS OCR507, STOR-X DATA LOGGER 16" BATTERY HOUSING TC INVERTED5 METERS 1" SAS INDUCTIVE CABLE BREAKOUT RADAR REFLECTOR OS PAPA RECOVERY HANDLE 1 METER-SBE 37 MICROCAT TC HUMIDITY (FLEX) CTD/GTD/O2 4 METERS WETLabs FLNTUSB FLUOROMETER DOUBLE NUT AND TORQUE ALL LOAD CELL NUTS

  13. VISITOR PARKING Pay station parking meters are available around

    E-Print Network [OSTI]

    temporary parking needs. Daily scratch-off permits are available in advance from Parking Services. LOT METER PAY STATION RATES (SUMMER RATES MAY BE DISCOUNTED) HOW DO I GET A PERMIT? When parking on campus, a CSM parking permit is required Monday through Friday, from 7AM until 5 PM. Permits authorize parking

  14. BPA Metering Servicesź Editing and Estimating Procedures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Editing and Estimating Interval Data 1. Introduction This section defines the meter interval data editing and estimation techniques performed by BPA's Metering Services...

  15. Smart Meter Company Boosting Production, Workforce | Department...

    Broader source: Energy.gov (indexed) [DOE]

    Smart Meter Company Boosting Production, Workforce Smart Meter Company Boosting Production, Workforce September 30, 2010 - 10:53am Addthis Kevin Craft What does this mean for me?...

  16. BBEE Public Utility Conference Call

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and what their track records are. Leveraging Smart GridAMI Some utilities involved in smart grid and investing in advanced metering infrastructure (AMI) see BBEE as a natural...

  17. Assessing the Impacts of Wind Integration in the Western Provinces Amy Sopinka

    E-Print Network [OSTI]

    Victoria, University of

    Assessing the Impacts of Wind Integration in the Western Provinces by Amy Sopinka B.A., Queen the Impacts of Wind Integration in the Western Provinces by Amy Sopinka B.A., Queen's University, 1992 M and utilize high levels of renewable energy technology, such as wind power, depends upon the composition

  18. Role of AmiA in the Morphological Transition of Helicobacter pylori and in Immune Escape

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Role of AmiA in the Morphological Transition of Helicobacter pylori and in Immune Escape Catherine¬ī Paris-Sud, Orsay, France The human gastric pathogen Helicobacter pylori is responsible for peptic ulcers, Werts C, et al. (2006) Role of AmiA in the morphological transition of Helicobacter pylori and in immune

  19. AN ELECTRICAL OXYGEN-TEMPERATURE METER

    E-Print Network [OSTI]

    426 AN ELECTRICAL OXYGEN-TEMPERATURE METER FOR FISHERY BIOLOGISTS SEP 2 1196: vuUiJo HIM. . SPECIAL and Wildlife, Daniel H. Janzen, Director AN ELECTRICAL OXYGEN-TEMPERATURE METER FOR FISHERY BIOLOGISTS -temperature meter 11 Maintenance and trouble -shooting 12 #12;AN ELECTRICAL OXYGEN-TEMPERATURE METER

  20. Hardware Metering: A Survey Farinaz Koushanfar

    E-Print Network [OSTI]

    Chapter 1 Hardware Metering: A Survey Farinaz Koushanfar Abstract This chapter provides the first comprehensive overview of hard- ware integrated circuits (IC) protection by metering. Hardware metering, or IC metering refers to mechanisms, methods, and protocols that enable track- ing of the ICs post

  1. meter:alittlelonger kilometer:alittlemore

    E-Print Network [OSTI]

    Yard Meter meter:alittlelonger thanayard mile kilometer kilometer:alittlemore thanhalfamile gramM1000000 gigaG1000000000 COMMONPREFIXES 1 8765432 9 161514131211101 8765432 9 16151413121110 cm Yard Meter meter:alittlelonger thanayard mile kilometer kilometer:alittlemore thanhalfamile gram

  2. 2,270 METERS BOUYANT POLYOLEFIN MOORING LINE

    E-Print Network [OSTI]

    2,270 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METER LENGTH NYLON STIFFENER APPLIED TO 1" NYLON 3/4" SAS EYE INTO EYE SPLICE ACOUSTIC RELEASE 20 METERS 1 1/8" NYLON 5/8" SAS 5/8" SAS 3/4" SAS .5 METER CHAIN 697.4 METERS 7/16" WIRE ROPE 7.1 METERS 10 METERS 37.1 METERS 75 METERS 100 METERS 125 METERS 225

  3. Precision metering of germinated seeds

    E-Print Network [OSTI]

    Elliot, Gregory Lawrence

    1990-01-01T23:59:59.000Z

    actuated by an electrical solenoid was used to mechanically capture individual seeds. Air was used to eject the seeds from the system. A new single file device employing dilution flow was tested at rates as high as ten seeds per second. It produced... distribution was found to adequately represent the data. The metering system was tested at ejection rates ranging from 1. 3 to 4. 5 seeds per second, with most tests at rates between two and three seeds per second. The performance of the metering system...

  4. Station design using orifice meters

    SciTech Connect (OSTI)

    Upp, E.L. (Daniel Industries, Inc., Houston, TX (United States))

    1992-07-01T23:59:59.000Z

    This paper reports that proper meter station design using gas orifice meters must include consideration of a number of factors to minimize operation and maintenance problems while obtaining the best accuracy over the life of the station. A station should provide accuracy, be safe, functional, economical and free of undue maintenance. It should comply with all codes, reports and specifications but most of all it should be able to comply with terms set forth in the contract. All measuring stations should be designed with considerations of growth or reductions in volume. It should be attractive and built to last for many years.

  5. advanced in-core monitoring: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    T. 94 An Overview on Advance Metering System CiteSeer Summary: Abstract The term "Smart meter " typically refers to an electrical meter, but the term is also starting to be...

  6. [Article 1 of 7: Motivates and Includes the Consumer

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and include the consumer exist. Some examples include advanced two-way metering (AMI), demand response (DR), and distributed energy resources (DER). A common misconception is...

  7. South Mississippi Electric Power Association Smart Grid Project (Mississippi)

    Broader source: Energy.gov [DOE]

    South Mississippi Electric Power Associationís (SMEPA) smart grid project involves the deployment of advanced metering infrastructure (AMI) and covers the Generation and Transmission (G&T)...

  8. Pacific Northwest Smart Grid Demonstration Project SUCCESS STORIES

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    400,000 metered customers INVESTMENT IN PNWSGDP: * 2.1 million HIGHLIGHTS: * Demand response program * Distribution Voltage Reduciton * Advanced AMI communicatons net- work *...

  9. 2,309 METERS BOUYANT POLYOLEFIN MOORING LINE

    E-Print Network [OSTI]

    2,309 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METER LENGTH NYLON STIFFENER APPLIED TO 1" NYLON EYE INTO EYE SPLICE 20 METERS 1 1/8" NYLON 697.4 METERS 7/16" WIRE ROPE 36.1 METERS TC inverted35 METERS 40 METERS 700 METERS 3/4" SAS, Wrench tighten. ** 3/4" SAS WITH BUSHING, Wrench tighten. ** .5

  10. Electrical Metering Equipment and Sensors Appendix D -Electrical Metering Equipment and Sensors

    E-Print Network [OSTI]

    Appendix D ­ Electrical Metering Equipment and Sensors #12;D.1 Appendix D - Electrical Metering schedules, and view system status from the convenience of a standard web-browser. D.2 Metering Data Logger

  11. Meters

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas Conchas recovery challenge fund LasDubeyChallengeMetal & Alloyand RP-1 Agreement

  12. Government Program Briefing: Smart Metering

    Office of Energy Efficiency and Renewable Energy (EERE)

    This document is adapted and updated from a memo delivered to the City Council of New Orleans, the office of the Mayor of New Orleans, the Chairperson of the Citizen Stakeholders Group (New Orleans Energy Task Force) and the U.S. Department of Energy (DOE) Project Officer in March 2008. This briefing piece provides an overview of the benefits, costs, and challenges of smart metering.

  13. Government Program Briefing: Smart Metering

    SciTech Connect (OSTI)

    Doris, E.; Peterson, K.

    2011-09-01T23:59:59.000Z

    This document is adapted and updated from a memo delivered to the City Council of New Orleans, the office of the Mayor of New Orleans, the Chairperson of the Citizen Stakeholders Group (New Orleans Energy Task Force) and the U.S. Department of Energy (DOE) Project Officer in March 2008. This briefing piece provides an overview of the benefits, costs, and challenges of smart metering.

  14. Electric Metering | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehicles ¬Ľ AlternativeUpDrain-Water Heat RecoveryEarnedElectric Metering

  15. ARM MJO Investigation Experiment on Gan Island (AMIE-Gan) Science Plan

    SciTech Connect (OSTI)

    Long, CL; Del Genio, A; Deng, M; Fu, X; Gustafson, W; Houze, R; Jakob, C; Jensen, M; Johnson, R; Liu, X; Luke, E; May, P; McFarlane, S; Minnis, P; Schumacher, C; Vogelmann, A; Wang, Y; Webster, P; Xie, S; Zhang, C

    2011-04-11T23:59:59.000Z

    The overarching campaign, which includes the ARM Mobile Facility 2 (AMF2) deployment in conjunction with the Dynamics of the Madden-Julian Oscillation (DYNAMO) and the Cooperative Indian Ocean experiment on intraseasonal variability in the Year 2011 (CINDY2011) campaigns, is designed to test several current hypotheses regarding the mechanisms responsible for Madden-Julian Oscillation (MJO) initiation and propagation in the Indian Ocean area. The synergy between the proposed AMF2 deployment with DYNAMO/CINDY2011, and the corresponding funded experiment on Manus, combine for an overarching ARM MJO Investigation Experiment (AMIE) with two components: AMF2 on Gan Island in the Indian Ocean (AMIE-Gan), where the MJO initiates and starts its eastward propagation; and the ARM Manus site (AMIE-Manus), which is in the general area where the MJO usually starts to weaken in climate models. AMIE-Gan will provide measurements of particular interest to Atmospheric System Research (ASR) researchers relevant to improving the representation of MJO initiation in climate models. The framework of DYNAMO/CINDY2011 includes two proposed island-based sites and two ship-based locations forming a square pattern with sonde profiles and scanning precipitation and cloud radars at both island and ship sites. These data will be used to produce a Variational Analysis data set coinciding with the one produced for AMIE-Manus. The synergy between AMIE-Manus and AMIE-Gan will allow studies of the initiation, propagation, and evolution of the convective cloud population within the framework of the MJO. As with AMIE-Manus, AMIE-Gan/DYNAMO also includes a significant modeling component geared toward improving the representation of MJO initiation and propagation in climate and forecast models. This campaign involves the deployment of the second, marine-capable, AMF; all of the included measurement systems; and especially the scanning and vertically pointing radars. The campaign will include sonde launches at a rate of eight per day for the duration of the deployment. The increased sonde launches for the entire period matches that of the AMIE-Manus campaign and makes possible a far more robust Variational Analysis forcing data set product for the entire campaign, and thus better capabilities for modeling studies and synergistic research using the data from both AMIE sites.

  16. Metered Mail Form International Mail Only

    E-Print Network [OSTI]

    Palmeri, Thomas

    Metered Mail Form International Mail Only Charge to Department USPS First Class Mail International International Metered Mail Form and must be kept separate from all other domestic mail. · International mail

  17. Heating Energy Meter Validation for Apartments

    E-Print Network [OSTI]

    Cai, B.; Li, D.; Hao, B.

    2006-01-01T23:59:59.000Z

    Household heat metering is the core of heating system reform. Because of many subjective and objective factors, household heat metering has not been put into practice to a large extent in China. In this article, the research subjects are second...

  18. City of St. George- Net Metering

    Broader source: Energy.gov [DOE]

    The St. George City Council adopted a [http://www.sgcity.org/wp/power/NetMeteringPolicy.pdf net-metering program for area utilities], including interconnection procedures, in October 2005.* The...

  19. Long Island Power Authority- Net Metering

    Broader source: Energy.gov [DOE]

    : Note: In October 2012 the LIPA Board of Trustees adopted changes to the utility's net metering tariff that permit remote net metering for non-residential solar and wind energy systems, and farm...

  20. A restructuring agenda for developing competitive retail electric markets that is based on a low-cost, real-time, smart-kilowatt-hour meter adapter

    SciTech Connect (OSTI)

    Chasek, N.E.

    1997-12-31T23:59:59.000Z

    This paper proposes six agenda items that should expedite a politically smooth transition into a most efficient economically viable market-driven public power system. The agenda would introduce: the virtual marketplace for retail electric power, smart meters, smart meter readers, near-real-time load balancing and load apportionment, advanced supply and demand or commodity-style pricing, and reliability metering.

  1. Metering Schemes for General Access Structures

    E-Print Network [OSTI]

    Stinson, Douglas

    Metering Schemes for General Access Structures Barbara Masucci Dipartimento di Informatica ed, Canada E­mail: dstinson@cacr.math.uwaterloo.ca Abstract A metering scheme is a method by which an audit time frame. In this paper we construct metering schemes for more general access structures, which

  2. A PHOTOELECTRIC CURRENT METER Marine Biological Laboratory!

    E-Print Network [OSTI]

    330 A PHOTOELECTRIC CURRENT METER Marine Biological Laboratory! WOODS HOLE, MASS. SPECIAL CURRENT METER by H. C. Boyar Fishery Research Biologist Bureau of Commercial Fisheries Biological. March 1960 #12;#12;TABLE OF CONTENTS Page Introduction 1 Description and operation of the meter

  3. Newport Power Meter Drivers CD Installation Software

    E-Print Network [OSTI]

    Kleinfeld, David

    Newport Power Meter Drivers CD Installation Software Version 2.3.1 Revision Date: October 16, 2008 IMPORTANT NOTES: The USB drivers on your CD must be installed before the Newport Power Meter is connected to your PC (via USB cable). Manual: The latest manuals for the Newport Power Meters can be found

  4. THE ELECTRICAL RESISTIVITY METER IN FISHERY INVESTIGATIONS

    E-Print Network [OSTI]

    THE ELECTRICAL RESISTIVITY METER IN FISHERY INVESTIGATIONS I Marine Biological Laboratory! WOODS RESISTIVITY METER IN FISHERY INVESTIGATIONS By Robert E. Lennon Fishery Research Biologist Appalachian Sport) BiblioKiMpliy : p. ]!. 1. Electric meters. 2. Water--Analysis. 3. Electric fishing. I. Title. ( Series

  5. Metered Mail Form Domestic Mail Only

    E-Print Network [OSTI]

    Palmeri, Thomas

    Metered Mail Form Domestic Mail Only For USPS Mail Only Charge to Department First Class Mail Media Meter Form. · All outgoing USPS Mail that needs postage should be kept separate from all other mail already be sealed prior to being metered. Failure to properly seal this type of mail could result

  6. Smart Meter Security Infrastructure: Some Observations

    E-Print Network [OSTI]

    Ladkin, Peter B.

    to infer otherwise-private life-style details of the Smart Meter user. 2 An attacker who can issue on the capa- bility of the device, such an attacker can reset a Smart Meter, cut off electricity supply, access Smart Grid nodes via the Smart Meter, or pretend electricity use that is other than the actual use

  7. Privacy-Preserving Smart Metering Alfredo Rial

    E-Print Network [OSTI]

    Bernstein, Phil

    Privacy-Preserving Smart Metering Alfredo Rial K.U.Leuven, ESAT/COSIC & IBBT Leuven, Belgium General Terms Security Keywords Billing, Smart metering, Cryptographic Protocol, Verifiable Computing 1 of smart meter data for more accurate forecasting, Permission to make digital or hard copies of all or part

  8. 2,275 METERS BOUYANT POLYOLEFIN MOORING LINE

    E-Print Network [OSTI]

    2,275 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METERS NYLON STIFFENER 3/4" SAS .5 M 1/2" CHAIN 3" GLASS BALL FLOATS on 2.5 M Chain ACOUSTIC RELEASE 20 METERS 1 1/8" NYLON 5/8" SAS 5/8" SAS 3/4" SAS .5 METER CHAIN 5/8" SAS 2 METER CHAIN 697.4 METERS 7/16" WIRE ROPE SONTEK7 METERS 10 METERS 8.3 METERS TV

  9. 2,279 METERS BOUYANT POLYOLEFIN MOORING LINE

    E-Print Network [OSTI]

    2,279 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METERS NYLON STIFFENER 3/4" SAS .5 M 1/2" CHAIN 5 SPLICE 6 ea.17" GLASS BALL FLOATS ACOUSTIC RELEASE 20 METERS 1 1/8" NYLON 5/8" SAS 5/8" SAS 3/4" SAS .5 METER CHAIN 5/8" SAS 2 METER CHAIN TC INVERTED5 METERS 697.4 METERS WIRE ROPE SONTEK7 METERS 10 METERS 8

  10. Melodic cues to meter 1 Running Head: MELODIC CUES TO METER

    E-Print Network [OSTI]

    Ahmad, Sajjad

    Melodic cues to meter 1 Running Head: MELODIC CUES TO METER The Role of Melodic and Temporal Cues in Perceiving Musical Meter Erin E. Hannon Cornell University Joel S. Snyder Cornell University Tuomas Eerola-569-4326 Tel: 905-828-5415 E-mail: eeh5@cornell.edu #12;Melodic cues to meter 2 Abstract A number of different

  11. ANALYSIS OF HIGH PRESSURE TESTS ON WET GAS FLOW METERING WITH A VENTURI METER

    E-Print Network [OSTI]

    ANALYSIS OF HIGH PRESSURE TESTS ON WET GAS FLOW METERING WITH A VENTURI METER P. Gajan , Q, 64018 Pau cedex, France pierre.gajan@onera.fr Abstract This work deals with the flow metering of wet gas on the CEESI facilities are presented. They are performed at 75 bars with 0.6 beta ratio Venturi meter

  12. PQMII POWER QUALITY METER INSTRUCTION MANUAL 11 PQMII Power Quality Meter

    E-Print Network [OSTI]

    Meyers, Steven D.

    #12;#12;#12;PQMII POWER QUALITY METER ­ INSTRUCTION MANUAL 1­1 PQMII Power Quality Meter Chapter 1 Multilin PQMII Power Quality Meter is an ideal choice for continuous monitoring of a single or three-phase system. It provides metering for current, voltage, real power, reactive power, apparent power, energy use

  13. Ramp meters on trial: Evidence from the Twin Cities metering holiday

    E-Print Network [OSTI]

    Levinson, David M.

    Ramp meters on trial: Evidence from the Twin Cities metering holiday David Levinson a,*, Lei Zhang; accepted 15 December 2004 Abstract Ramp meters in the Twin Cities have been the subject of a recent test metering for several representative freeways during the afternoon peak period. Seven performance measures

  14. Microsoft Word - CX-Paisley_Meter_08Aug2013.doc

    Broader source: Energy.gov (indexed) [DOE]

    inspect SVEC's metering support installations, and install and test a new revenue meter. The new revenue meter would be installed in a fiberglass enclosure and would be wired...

  15. Cameras, PwrMeter,and MultiMeter rfi August 27, 1999 5 FIGURE 3: Power meter birdie with door closed.

    E-Print Network [OSTI]

    Cameras, PwrMeter,and MultiMeter rfi August 27, 1999 5 FIGURE 3: Power meter birdie with door closed. Fri Aug 27 23:17:58 1999 phil #12; Cameras, PwrMeter,and MultiMeter rfi August 27, 1999 4 FIGURE 2. Power meter, multimeter birdies with door closed. Fri Aug 27 23:14:06 1999 phil #12; Cameras, PwrMeter

  16. Farmington Electric Utility System- Net Metering

    Broader source: Energy.gov [DOE]

    Net metering rules developed by the New Mexico Public Regulation Commission (PRC) apply to the state's investor-owned utilities and electric cooperatives. Municipal utilities, which are not...

  17. Structured Security Testing in the Smartgrid Patrick McDaniel and Stephan McLaughlin

    E-Print Network [OSTI]

    McDaniel, Patrick Drew

    (AMI) is changing the way electric energy is produced, priced, and consumed. The introduction of the tree are the attacks necessary for energy fraud. The final attribute of the tree is the conjunctions,smclaugh}@cse.psu.edu Abstract--The advanced metering infrastructure (AMI) is revolutionizing electrical grids. Intelligent AMI

  18. Proton recoil scintillator neutron rem meter

    DOE Patents [OSTI]

    Olsher, Richard H. (Los Alamos, NM); Seagraves, David T. (Los Alamos, NM)

    2003-01-01T23:59:59.000Z

    A neutron rem meter utilizing proton recoil and thermal neutron scintillators to provide neutron detection and dose measurement. In using both fast scintillators and a thermal neutron scintillator the meter provides a wide range of sensitivity, uniform directional response, and uniform dose response. The scintillators output light to a photomultiplier tube that produces an electrical signal to an external neutron counter.

  19. Operations and Maintenance Savings from Advanced Metering Infrastructure - Initial Results

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l L d F SSales LLCDiesel Engines |OpenEnergy 8Operations U.S.

  20. 2010 Assessment of Demand Response and Advanced Metering - Staff Report |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up from theDepartment( Sample of ShipmentSimulation, Analysisof annualDepartmentOffice

  1. Category:Smart Grid Projects - Advanced Metering Infrastructure | Open

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectricEnergyCTBarreis aCallahanWind FarmAddSRML Map FilesEnergy Information

  2. US Recovery Act Smart Grid Projects - Advanced Metering Infrastructure |

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to:Seadov PtyInformation UC 19-6-401 et seq. - UtahAsiaEnviroFuels LLCOpen Energy

  3. BEAMFORMING MAXIMIZES THE MISO COMPOUND CAPACITY Ami Wiesel, Yonina C. Eldar and Shlomo Shamai (Shitz)

    E-Print Network [OSTI]

    Eldar, Yonina

    BEAMFORMING MAXIMIZES THE MISO COMPOUND CAPACITY Ami Wiesel, Yonina C. Eldar and Shlomo Shamai for exploiting this multiple in- put single output (MISO) channel are space time coding, and beamforming (BF]. The capacity achieving transmit technique in MISO chan- nels with additive Gaussian noise is signaling using

  4. BBuulllleettiinnJUNE 2009 DR. AMY WRIGHT NAMED FAU RESEARCHER OF THE YEAR

    E-Print Network [OSTI]

    Fernandez, Eduardo

    BBuulllleettiinnJUNE 2009 DR. AMY WRIGHT NAMED FAU RESEARCHER OF THE YEAR Florida Atlantic Wright was selected for her breakthrough work in the category of Professor, Sponsored/ Project-Oriented work. Dr. Wright's research focuses on the discovery of novel marine natural products that have utility

  5. Amy G. Froelich Ph.D. in Statistics 10/00

    E-Print Network [OSTI]

    Froelich, Amy G.

    Amy G. Froelich Education Ph.D. in Statistics 10/00 University of Illinois at Urbana-Champaign Highest University Honors - Bronze Tablet Professional Employment Associate Professor 8/08 - present Department of Statistics, Iowa State University Faculty Member 8/06 - present Master of School Mathematics

  6. Centralized route recovery based on multi-hop wakeup time estimation for wireless sensor networks with ultra low duty cycles

    E-Print Network [OSTI]

    Bahk, Saewoong

    of smart-meters that are interconnected to construct meshed wireless sensor networks. A smart meter data from each smart-meter are gathered into concentrators, and delivered to AMI (Advanced Metering Infrastructure) server through PLC (Power Line Communication) or public wireless networks. Since the smart-meter

  7. City of New Orleans- Net Metering

    Broader source: Energy.gov [DOE]

    In May 2007, the New Orleans City Council adopted net-metering rules that are similar to rules adopted by the Louisiana Public Service Commission (PSC) in November 2005. The City Council's rules...

  8. Hydro-Quťbec Net Metering (Quebec, Canada)

    Broader source: Energy.gov [DOE]

    In line with Hydro-Quťbec's commitment to the environment and sustainable development, Hydro-Quťbec is supporting self-generation with a new rate offering: the net metering option. This option...

  9. Murray City Power- Net Metering Pilot Program

    Broader source: Energy.gov [DOE]

    Under a pilot program, Murray City Power offers net metering to customers that generate electricity using photovoltaic (PV), wind-electric or hydroelectric systems with a maximum capacity of 10...

  10. U.S. Virgin Islands- Net Metering

    Broader source: Energy.gov [DOE]

    In February 2007, the U.S. Virgin Islands Public Services Commission approved a limited net-metering program for residential and commercial photovoltaic (PV), wind-energy or other renewable energy...

  11. Working With Your Utility to Obtain Metering Services

    Broader source: Energy.gov [DOE]

    Presentationógiven at the Spring 2013 Federal Utility Partnership Working Group (FUPWG) meetingócovers the government metering requirement, the U.S. Department of Defense (DoD) metering directive, and customer metering services available from utilities.

  12. You Can Justify Meters for Your Energy Conservation Program

    E-Print Network [OSTI]

    Rusnak, J. J.

    1981-01-01T23:59:59.000Z

    Meters don't save energy' This statement has often concluded a meeting or terminated a budget request leaving the metering proponent feeling frustrated. Such a statement is technically correct when meters are evaluated in the same way as equipment...

  13. Use Meters to Put Teeth into Your Conservation Programs

    E-Print Network [OSTI]

    Hayes, J. W.; Rusnak, J. J.

    1980-01-01T23:59:59.000Z

    is effective flow metering, but that is a difficult job even in more traditional applications. The problem is compounded by the fact that traditional metering concepts are inadequate for the unique problems presented by retro-metering for in...

  14. 2,279 METERS BOUYANT POLYOLEFIN MOORING LINE

    E-Print Network [OSTI]

    2,279 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METERS NYLON STIFFENER 3/4" SAS .5 M 1/2" CHAIN 5 SPLICE 17" GLASS BALL FLOATS 5/8" SAS 5/8" SAS 3 TON SWIVEL ACOUSTIC RELEASE 20 METERS 1 1/8" NYLON 5/8" SAS 5/8" SAS 3/4" SAS .5 METER CHAIN 5/8" SAS 2 METER CHAIN .5 METER CHAIN 3/4" SAS WITH BUSHING TC

  15. Breast Tissue Parameter Identification for a Nonlinear Constitutive Model Petr Jordan, Amy E. Kerdok, Simona Socrate, Robert D. Howe

    E-Print Network [OSTI]

    Breast Tissue Parameter Identification for a Nonlinear Constitutive Model Petr Jordan, Amy E modulus, bulk modulus, prestretch, locking stretch, and relative permeability), we solve the inverse, locking stretch, and bulk modulus increase while the relative permeability decreases with pathological

  16. Portland Advancing Green Image With Solar Installs | Department...

    Broader source: Energy.gov (indexed) [DOE]

    Portland Advancing Green Image With Solar Installs Portland Advancing Green Image With Solar Installs February 22, 2010 - 12:10pm Addthis Laura Smoyer checks the net-metering...

  17. INSTRUCTION MANUAL digital pH/mV meter

    E-Print Network [OSTI]

    Kleinfeld, David

    INSTRUCTION MANUAL model 701A digital pH/mV meter /r^ ORION RESEARCH #12;contents Introduction 1 701A digital pH/mV meter is the ideal meter for all research and precision measurements with pH and chemical sensing electrodes. In both the absolute and relative mV modes, the meter covers a range of ¬Ī 1999

  18. Monitoring Massive Appliances by a Minimal Number of Smart Meters

    E-Print Network [OSTI]

    Wang, Yongcai

    56 Monitoring Massive Appliances by a Minimal Number of Smart Meters YONGCAI WANG, XIAOHONG HAO. This article presents a framework for deploying a minimal number of smart meters to accurately track the ON of required smart meters is studied by an entropy-based approach, which qualifies the impact of meter

  19. SOLVENT DISPERSION AND FLOW METER CALCULATION RESULTS

    SciTech Connect (OSTI)

    Nash, C.; Fondeur, F.; Peters, T.

    2013-06-21T23:59:59.000Z

    Savannah River National Laboratory (SRNL) found that the dispersion numbers for the six combinations of CSSX:Next Generation Solvent (NGS) ďblendĒ and pure NGS versus salt solution, caustic wash, and strip aqueous solutions are all good. The dispersion numbers are indications of processability with centrifugal contactors. A comparison of solvent physical and thermal properties shows that the Intekô solvent flow meter in the plant has a reading biased high versus calibrated flow when NGS is used, versus the standard CSSX solvent. The flow meter, calibrated for CSSX solvent, is predicted to read 2.8 gpm of NGS in a case where the true flow of NGS is 2.16 gpm.

  20. Liquid metal Flow Meter - Final Report

    SciTech Connect (OSTI)

    Andersen C, Hoogendoom S, Hudson B, Prince J, Teichert K, Wood J, Chase K

    2007-01-30T23:59:59.000Z

    Measuring the flow of liquid metal presents serious challenges. Current commercially-available flow meters use ultrasonic, electromagnetic, and other technologies to measure flow, but are inadequate for liquid metal flow measurement because of the high temperatures required by most liquid metals. As a result of the reactivity and high temperatures of most liquid metals, corrosion and leakage become very serious safety concerns. The purpose of this project is to develop a flow meter for Lockheed Martin that measures the flow rate of molten metal in a conduit.

  1. Draft-O-Meter | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat Pump Models |Conduct, Parent(CRADA and DOWDepartmentDraft-O-Meter Draft-O-Meter

  2. Algorithms for revenue metering and their evaluation

    E-Print Network [OSTI]

    Martinez-Lagunes, Rodrigo

    2000-01-01T23:59:59.000Z

    conditions are well accepted among the metering community. But in recent years, due to the increase of non-linear loads, the presence of harmonics in the current and voltage waveforms in the power network has increased notably, and in the future years...

  3. NATL Grid Map 50-Meter Grid

    E-Print Network [OSTI]

    Slatton, Clint

    NATL-east NATL Grid Map 50-Meter Grid Locations in NATL can be specified by reference to a grid intervals. Each gridline intersection ("grid point") is identified by its two gridlines (e.g., E5). Each 50x50-m block formed by the gridlines is identified by the grid point in its northwest corner (e

  4. Laser Power Meter Large, bright, backlit LCD

    E-Print Network [OSTI]

    Woodall, Jerry M.

    Laser Power Meter FEATURES ¬∑ Large, bright, backlit LCD display ¬∑ Digital accuracy with analog-like movement for laser tuning ¬∑ Works with thermopile and optical sensors ¬∑ Intuitive button-driven user COMPATIBILITY ¬∑ PowerMax¬ģ thermal sensors ¬∑ Optical sensors FieldMaxII-TO Coherent Laser Measurement and Control

  5. Self-Organization of a Mesh Hierarchy for Smart Grid Monitoring in Outage Scenarios

    E-Print Network [OSTI]

    Tague, Patrick

    communication infrastructure in the smart grid is not robust for data collection from smart meters during/generating elements in the smart environment to a gateway. We envision this gateway to be a smart meter. The collection of smart-meters and collectors form the smart grid Advanced Metering Infrastructure (AMI) [1

  6. AMIS (Smart Grid Project) (Vöcklabruck, Austria) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartmentAUDIT REPORTOpenWende NewSowitec doWinvestFlumeFinalAIRMaster+AMIS (Smart Grid

  7. AMI System Security Requirements - v1_01-1 | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustionImprovement3 Beryllium-Associated6-05.pdf AL2006-05.pdfAMI System Security Requirements -

  8. Fuel cell membrane hydration and fluid metering

    DOE Patents [OSTI]

    Jones, Daniel O. (Glenville, NY); Walsh, Michael M. (Fairfield, CT)

    2003-01-01T23:59:59.000Z

    A hydration system includes fuel cell fluid flow plate(s) and injection port(s). Each plate has flow channel(s) with respective inlet(s) for receiving respective portion(s) of a given stream of reactant fluid for a fuel cell. Each injection port injects a portion of liquid water directly into its respective flow channel. This serves to hydrate at least corresponding part(s) of a given membrane of the corresponding fuel cell(s). The hydration system may be augmented by a metering system including flow regulator(s). Each flow regulator meters an injecting at inlet(s) of each plate of respective portions of liquid into respective portion(s) of a given stream of fluid by corresponding injection port(s).

  9. Resonant speed meter for gravitational wave detection

    E-Print Network [OSTI]

    Atsushi Nishizawa; Seiji Kawamura; Masa-aki Sakagami

    2008-05-01T23:59:59.000Z

    Gravitational-wave detectors have been well developed and operated with high sensitivity. However, they still suffer from mirror displacement noise. In this paper, we propose a resonant speed meter, as a displacement noise-canceled configuration based on a ring-shaped synchronous recycling interferometer. The remarkable feature of this interferometer is that, at certain frequencies, gravitational-wave signals are amplified, while displacement noises are not.

  10. Two-Meter Temperature Surveys for Geothermal Exploration Project...

    Open Energy Info (EERE)

    Two-Meter Temperature Surveys for Geothermal Exploration Project at NAS Fallon Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Two-Meter...

  11. The Need for Essential Consumer Protections: Smart metering proposals...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    metering proposals and the move to time-based pricing. August 2010 The Need for Essential Consumer Protections: Smart metering proposals and the move to time-based pricing. August...

  12. ARRA Program Celebrates Milestone 600,000 Smart Meter Installations...

    Broader source: Energy.gov (indexed) [DOE]

    ARRA Program Celebrates Milestone 600,000 Smart Meter Installations ARRA Program Celebrates Milestone 600,000 Smart Meter Installations April 17, 2012 - 3:09pm Addthis On April 11,...

  13. Wireless Electricity Metering of Miscellaneous and Electronic Devices in Buildings

    E-Print Network [OSTI]

    Culler, David E.

    Wireless Electricity Metering of Miscellaneous and Electronic Devices in Buildings, University of California, Berkeley, USA Abstract- Miscellaneous and electronic devices hundreds of miscellaneous and electronic devices where metered for several months

  14. Secretary Chu Announces Two Million Smart Grid Meters Installed...

    Energy Savers [EERE]

    Two Million Smart Grid Meters Installed Nationwide Secretary Chu Announces Two Million Smart Grid Meters Installed Nationwide August 31, 2010 - 12:00am Addthis Columbus, OH - At an...

  15. Microsoft Word - CX -Lewis County PUD metering_.doc

    Broader source: Energy.gov (indexed) [DOE]

    of meter data at 5 minute intervals is required of BPA Slice customers to perform power scheduling. In order to provide this data, BPA needs to install meter equipment by January...

  16. Author's personal copy Ramp metering and freeway bottleneck capacity

    E-Print Network [OSTI]

    Levinson, David M.

    ; Hall and Agyemang-Duah, 1991; Banks, 1991a,b). The two-capacity hypothesis argues that metering can

  17. Shared Signals: Using Existing Facility Meters for Energy Savings Verification

    E-Print Network [OSTI]

    McBride, J. R.; Bohmer, C. J.; Price, S. D.; Carlson, K.; Lopez, J.

    energy conservation projects. (2) These guidelines provide monitoring and verification options that have different levels of accuracy and cost. They are specifically designed for energy savings performance contracts and are designed to provide... with a fair degree of accuracy. The costs of using existing meters are often not as clear. Obviously, if an existing meter is used, the costs of purchasing new metering equipment is avoided. However, using an existing meter is not free of costs...

  18. Advanced Demand Side Management for the Future Smart Grid Using Mechanism Design

    E-Print Network [OSTI]

    Wong, Vincent

    meter. All smart meters are connected to not only the power grid but also a communication infrastructure. This allows two-way communication among smart meters and the utility company. We analytically model each user1 Advanced Demand Side Management for the Future Smart Grid Using Mechanism Design Pedram Samadi

  19. RIS-M-2254 ON A RADIOCHROMIC DYE DOSE METER

    E-Print Network [OSTI]

    RIS√?-M-2254 ON A RADIOCHROMIC DYE DOSE METER Arne Miller and William L. McLaughlin Abstract. Radiochromic dye dose meters made of polyvinyl butyral (PVB) with hexa(hydroxyethyl)pararosaniline cyanide (HPR results and outlines plans for further research on this dose meter. Currently the response is found

  20. ONE GEV BEAM ACCELERATION IN A ONE METER LONG

    E-Print Network [OSTI]

    ONE GEV BEAM ACCELERATION IN A ONE METER LONG PLASMA CELL A Proposal to the Stanford Linear. A single SLC bunch is used to both induce wakefields in the one meter long plasma and to witness that are needed to apply high-gradient plasma wakefield acceleration to large scale accelerators. The one meter

  1. Model 1918-C Hand-held Optical Meter

    E-Print Network [OSTI]

    Kleinfeld, David

    Model 1918-C Hand-held Optical Meter Start Up Guide #12;Start Up Guide 1 First printing 2006 © 2006, including safety precautions and start up procedures, needed to get your new optical meter up and running the use and operation of the optical meter is included in the complete User's Manual. The complete User

  2. Math for Poets and Drummers The Mathematics of Meter

    E-Print Network [OSTI]

    Hall, Rachel W.

    Math for Poets and Drummers The Mathematics of Meter Rachel Hall Saint Joseph's University 5600 a number of problems that are explored in class. In English and Spanish, the rhythm, or meter, of a piece- speare are written in the meter called iambic pentameter: five pairs of alternating unstressed

  3. Arnold Schwarzenegger TIME-OF-USE WATER METER EFFECTS

    E-Print Network [OSTI]

    Arnold Schwarzenegger Governor TIME-OF-USE WATER METER EFFECTS ON CUSTOMER WATER USE; Master Meter Ed Amelung; Southern California Edison Company ­ Matt Garcia, Curtis DeWoody, and James · Transportation TimeofUse Water Meter Impacts on Customer Water Use is the final report for the project 500 07022

  4. Smart Meter Deployment Optimization for Efficient Electrical Appliance State Monitoring

    E-Print Network [OSTI]

    Wang, Yongcai

    Smart Meter Deployment Optimization for Efficient Electrical Appliance State Monitoring Xiaohong approaches generally require large-scale smart sensor/meter networks, and thus suffer from the high to optimize the smart meter deployments to track the on/off states of the massive electrical appliances

  5. HOMOMORPHIC PRIMITIVES FOR A PRIVACY-FRIENDLY SMART METERING ARCHITECTURE

    E-Print Network [OSTI]

    Hellebrand, Sybille

    HOMOMORPHIC PRIMITIVES FOR A PRIVACY-FRIENDLY SMART METERING ARCHITECTURE Benjamin Vetter1 , Osman.lastname}@haw-hamburg.de, {firstname.lastname}@uni-paderborn.de Keywords: PET for smart metering, homomorphic MACs, homomorphic encryption Abstract: We propose a privacy-friendly smart metering architecture which is yet flexible enough

  6. Optimal Privacy-Preserving Energy Management for Smart Meters

    E-Print Network [OSTI]

    Reisslein, Martin

    Optimal Privacy-Preserving Energy Management for Smart Meters Lei Yang, Xu Chen, Junshan Zhang Abstract--Smart meters, designed for information collection and system monitoring in smart grid, report a tradeoff between the smart meter data privacy and the electricity bill. In general, a major challenge

  7. Security and Smart Metering Sophia Kaplantzis and Y. Ahmet Sekercioglu

    E-Print Network [OSTI]

    Sekercioglu, Y. Ahmet

    Security and Smart Metering Sophia Kaplantzis and Y. Ahmet S¬łekercioglu Department of Electrical the transmission network, to the suppliers back office. It encompasses concepts such as smart metering, smart does this threat translate to smart metering applications? In this article, we focus on the security

  8. Privacy Preserving Smart Metering System Based Retail Level Electricity Market

    E-Print Network [OSTI]

    Franchetti, Franz

    1 Privacy Preserving Smart Metering System Based Retail Level Electricity Market Cory Thoma, Tao Cui, Student Member, IEEE, Franz Franchetti, Member, IEEE Abstract--Smart metering systems multi-party compu- tation (SMC) based privacy preserving smart metering system. Using the proposed SMC

  9. Secure Multiparty Computation Based Privacy Preserving Smart Metering System

    E-Print Network [OSTI]

    Franchetti, Franz

    Secure Multiparty Computation Based Privacy Preserving Smart Metering System Cory Thoma Information Ave. Pittsburgh, PA 15213 Email: {tcui,franzf}@ece.cmu.edu Abstract--Smart metering systems provide privacy preserving protocol for smart meter based load management. Using SMC and a proper designed

  10. Smart Meter Aware Domestic Energy Trading Agents Nicola Capodieci

    E-Print Network [OSTI]

    Aiello, Marco

    Smart Meter Aware Domestic Energy Trading Agents Nicola Capodieci University of Modena and RE illustrate an implementation includ- ing the interfacing with a physical Smart Meter and provide initial--Intelligent agents, Multiagent systems General Terms Design, Economy Keywords Energy trade, agents, smart meter 1

  11. Embedded Cyber-Physical Anomaly Detection in Smart Meters

    E-Print Network [OSTI]

    Embedded Cyber-Physical Anomaly Detection in Smart Meters Massimiliano Raciti, Simin Nadjm vulnerabilities that arise from deployment of local cyber-physical attacks at a smart metering location at destabilisation. In this paper we study a smart metering device that uses a trusted platform for storage

  12. Leveraging smart meter data to recognize home appliances Markus Weiss+#

    E-Print Network [OSTI]

    Leveraging smart meter data to recognize home appliances Markus Weiss+# , Adrian Helfenstein -- The worldwide adoption of smart meters that measure and communicate residential electricity consumption gives demand. In this paper we present an infrastructure and a set of algorithms that make use of smart meters

  13. Security Architecture of Smart Metering Systems Natasa Zivic1

    E-Print Network [OSTI]

    Boyer, Edmond

    Security Architecture of Smart Metering Systems Natasa Zivic1 and Christoph Ruland1 1 University.Zivic, Christoph.Ruland}@uni-siegen.de Abstract. The main goals of smart metering are the reduction of costs dynamically the power generation and distribution to the requested energy by smart grids. Metering devices

  14. Amy Ross

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD)ProductssondeadjustsondeadjustAbout theOFFICEAmes Laboratory Site Sustainability

  15. OTRA-THS MAC to reduce Power Outage Data Collection Latency in a smart meter network

    SciTech Connect (OSTI)

    Garlapati, Shravan K [ORNL] [ORNL; Kuruganti, Phani Teja [ORNL] [ORNL; Buehrer, Richard M [ORNL] [ORNL; Reed, Jeffrey H [ORNL] [ORNL

    2014-01-01T23:59:59.000Z

    The deployment of advanced metering infrastructure by the electric utilities poses unique communication challenges, particularly as the number of meters per aggregator increases. During a power outage, a smart meter tries to report it instantaneously to the electric utility. In a densely populated residential/industrial locality, it is possible that a large number of smart meters simultaneously try to get access to the communication network to report the power outage. If the number of smart meters is very high of the order of tens of thousands (metropolitan areas), the power outage data flooding can lead to Random Access CHannel (RACH) congestion. Several utilities are considering the use of cellular network for smart meter communications. In 3G/4G cellular networks, RACH congestion not only leads to collisions, retransmissions and increased RACH delays, but also has the potential to disrupt the dedicated traffic flow by increasing the interference levels (3G CDMA). In order to overcome this problem, in this paper we propose a Time Hierarchical Scheme (THS) that reduces the intensity of power outage data flooding and power outage reporting delay by 6/7th, and 17/18th when compared to their respective values without THS. Also, we propose an Optimum Transmission Rate Adaptive (OTRA) MAC to optimize the latency in power outage data collection. The analysis and simulation results presented in this paper show that both the OTRA and THS features of the proposed MAC results in a Power Outage Data Collection Latency (PODCL) that is 1/10th of the 4G LTE PODCL.

  16. Smart-Metering for Monitoring Building Power Distribution Network using Instantaneous Phasor Computations of Electrical Signals

    E-Print Network [OSTI]

    K.R., Krishnanand

    2013-01-01T23:59:59.000Z

    efficient operation of a smart meter network . in IndustrialGood standards for smart meters . in European EnergyHardware development for Smart Meter based innovations . in

  17. Weak measurements with a qubit meter

    E-Print Network [OSTI]

    Shengjun Wu; Klaus MÝlmer

    2009-11-13T23:59:59.000Z

    We derive schemes to measure the so-called weak values of quantum system observables by coupling of the system to a qubit meter system. We highlight, in particular, the meaning of the imaginary part of the weak values, and show how it can be measured directly on equal footing with the real part of the weak value. We present compact expressions for the weak value of single qubit observables and of product observables on qubit pairs. Experimental studies of the results are suggested with cold trapped ions.

  18. Smart Meters | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating Solar PowerstoriesNrelPartnerTypePonsa, Mallorca:upGuidebook Jump to:SmarrMeters Home

  19. Federal Metering Requirements | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPCofConstructionofFYOxideof1 DOEFederalIncentives forMetering

  20. Power Metering Project | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in3.pdfEnergyDepartment ofOil'sof Energy Jun Luof EmergencyMetering Project Power

  1. Metering Technology Corporation | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: Energy Resources Jump to:46 -Energieprojekte GmbH Jump to: navigation,Metalysis Jump to:Dec 2005TananaMetering

  2. Investigations of Possible Low-Level Temperature and Moisture Anomalies During the AMIE Field Campaign on Manus Island

    SciTech Connect (OSTI)

    Long, CN; Holdridge, DJ

    2012-11-19T23:59:59.000Z

    This document discusses results stemming from the investigation of near-surface temperature and moisture ďodditiesĒ that were brought to light as part of the Atmospheric Radiation Measurement (ARM) Madden-Julian Oscillation (MJO) Investigation Experiment (AMIE), Dynamics of the Madden-Julian Oscillation (DYNAMO), and Cooperative Indian Ocean experiment on intraseasonal variability in the Year 2011 (CINDY2011) campaigns.

  3. 2,363 METERS BOUYANT 7/8" POLYOLEFIN MOORING LINE

    E-Print Network [OSTI]

    2,363 METERS BOUYANT 7/8" POLYOLEFIN MOORING LINE 10 METER LENGTH NYLON STIFFENER APPLIED TO TOP OF 1" NYLON EYE INTO EYE SPLICE 20 METERS 1 1/8" NYLON 697.4 METERS 7/16" WIRE ROPE 35 METERS 40 METERS 700 METERS 3/4" SAS, Wrench tighten. ** 3/4" SAS WITH BUSHING, Wrench tighten. ** .5 METER 1/2" CHAIN

  4. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    SciTech Connect (OSTI)

    Darghouth, Naim; Barbose, Galen; Wiser, Ryan

    2010-03-30T23:59:59.000Z

    Net metering has become a widespread policy in the U.S. for supporting distributed photovoltaics (PV) adoption. Though specific design details vary, net metering allows customers with PV to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption - in effect, compensating the PV generation at retail electricity rates (Rose et al. 2009). While net metering has played an important role in jump-starting the residential PV market in the U.S., challenges to net metering policies have emerged in a number of states and contexts, and alternative compensation methods are under consideration. Moreover, one inherent feature of net metering is that the value of the utility bill savings it provides to customers with PV depends heavily on the structure of the underlying retail electricity rate, as well as on the characteristics of the customer and PV system. Consequently, the value of net metering - and the impact of moving to alternative compensation mechanisms - can vary substantially from one customer to the next. For these reasons, it is important for policymakers and others that seek to support the development of distributed PV to understand both how the bill savings varies under net metering, and how the bill savings under net metering compares to other possible compensation mechanisms. To advance this understanding, we analyze the bill savings from PV for residential customers of California's two largest electric utilities, Pacific Gas and Electric (PG&E) and Southern California Edison (SCE). The analysis is based on hourly load data from a sample of 215 residential customers located in the service territories of the two utilities, matched with simulated hourly PV production for the same time period based on data from the nearest of 73 weather stations in the state.

  5. Method and apparatus for reading meters from a video image

    DOE Patents [OSTI]

    Lewis, Trevor J. (Irwin, PA); Ferguson, Jeffrey J. (North Huntingdon, PA)

    1997-01-01T23:59:59.000Z

    A method and system to enable acquisition of data about an environment from one or more meters using video images. One or more meters are imaged by a video camera and the video signal is digitized. Then, each region of the digital image which corresponds to the indicator of the meter is calibrated and the video signal is analyzed to determine the value indicated by each meter indicator. Finally, from the value indicated by each meter indicator in the calibrated region, a meter reading is generated. The method and system offer the advantages of automatic data collection in a relatively non-intrusive manner without making any complicated or expensive electronic connections, and without requiring intensive manpower.

  6. Test procedures help ensure accuracy of orifice meters

    SciTech Connect (OSTI)

    Fillman, C.R. [Coastal Flow Measurement, Inc., Houston, TX (United States)

    1996-07-01T23:59:59.000Z

    Orifice meter measurement with a chart recorder has been a standard in the petroleum industry for years. The meter consists of the plate/tube and recorder, requires minimal maintenance and can accurately measure a wide range of flow rates. It must be routinely tested to ensure sustained accuracy. The orifice meter measures differential pressure, static pressure, and temperature. However, the accuracy of the measurement is only as good as the calibration devices used in the test. A typical meter test consists of meter calibration, orifice plate inspection, quality of gas tests, and documentation (test report) to verify the data. The paper describes 19 steps that a gas technician can follow to conduct a thorough meter test.

  7. 2,349 METERS BOUYANT 7/8" POLYOLEFIN MOORING LINE

    E-Print Network [OSTI]

    2,349 METERS BOUYANT 7/8" POLYOLEFIN MOORING LINE 10 METER LENGTH NYLON STIFFENER APPLIED TO 1" NYLON EYE INTO EYE SPLICE 697.4 METERS 7/16" WIRE ROPE 40 METERS 700 METERS 3/4" SAS, Wrench tighten. ** 3/4" SAS WITH BUSHING, Wrench tighten. ** .5 METER 1/2" CHAIN 5 TON SWIVEL INDUCTIVE CABLE BREAKOUT

  8. Basic DC Meter Design ECE 2100 Circuit Analysis Laboratory

    E-Print Network [OSTI]

    Miller, Damon A.

    Basic DC Meter Design ECE 2100 Circuit Analysis Laboratory updated 8 January 2008 Pre-Laboratory Assignment 1. Design an ammeter with full scale current IFS equal to 5 mA using a meter movement rated at 0.5 mA and 100 mV. 2. Design a voltmeter with a full scale voltage VFS equal to 10 V using the meter

  9. Smart Metering and Electricity Demand: Technology, Economics and International Experience

    E-Print Network [OSTI]

    Brophy Haney, A; Jamasb, Tooraj; Pollitt, Michael G.

    www.eprg.group.cam.ac.uk E P R G W O R K IN G P A P E R Abstract Smart Metering and Electricity Demand: Technology, Economics and International Experience EPRG Working Paper EPRG0903 Cambridge Working Paper in Economics 0905 Aoife... Brophy Haney, Tooraj Jamasb and Michael G. Pollitt In recent years smart metering of electricity demand has attracted attention around the world. A number of countries and regions have started deploying new metering systems; and many others have...

  10. Deployment of High Resolution Real-Time Distribution Level Metering on Maui: Preprint

    SciTech Connect (OSTI)

    Bank, J.

    2013-01-01T23:59:59.000Z

    In order to support the ongoing Maui Smart Grid demonstration project advanced metering has been deployed at the distribution transformer level in Maui Electric Company's Kihei Circuit on the Island of Maui. This equipment has been custom designed to provide accurately time-stamped Phasor and Power Quality data in real time. Additionally, irradiance sensors have been deployed at a few selected locations in proximity to photovoltaic (PV) installations. The received data is being used for validation of existing system models and for impact studies of future system hardware. Descriptions of the hardware and its installation, and some preliminary metering results are presented. Real-time circuit visualization applications for the data are also under development.

  11. Maritime Electric- Net Metering (Prince Edward Island, Canada)

    Broader source: Energy.gov [DOE]

    In December 2005 The Renewable Energy Act and associated Regulations came into effect. A Government policy objective incorporated in the Act was the introduction of net metering for...

  12. Wavelength meter having single mode fiber optics multiplexed inputs

    DOE Patents [OSTI]

    Hackel, R.P.; Paris, R.D.; Feldman, M.

    1993-02-23T23:59:59.000Z

    A wavelength meter having a single mode fiber optics input is disclosed. The single mode fiber enables a plurality of laser beams to be multiplexed to form a multiplexed input to the wavelength meter. The wavelength meter can provide a determination of the wavelength of any one or all of the plurality of laser beams by suitable processing. Another aspect of the present invention is that one of the laser beams could be a known reference laser having a predetermined wavelength. Hence, the improved wavelength meter can provide an on-line calibration capability with the reference laser input as one of the plurality of laser beams.

  13. Optimization Online - A Security Framework for Smart Metering with ...

    E-Print Network [OSTI]

    Cristina Rottondi

    2011-12-05T23:59:59.000Z

    Dec 5, 2011 ... Abstract: The increasing diffusion of Automatic Meter Reading (AMR) has raised many concerns about the protection of personal data related to†...

  14. Scotia Energy Electricity- Net Metering Program (Nova Scotia, Canada)

    Broader source: Energy.gov [DOE]

    Nova Scotia Power Inc. Net Metering allows residential and commercial customers to connect small, renewable energy generating units to the provincial power grid.

  15. Pantex installs new meters to help to reduce energy consumption...

    National Nuclear Security Administration (NNSA)

    installs new meters to help to reduce energy consumption | National Nuclear Security Administration Facebook Twitter Youtube Flickr RSS People Mission Managing the Stockpile...

  16. Wavelength meter having single mode fiber optics multiplexed inputs

    DOE Patents [OSTI]

    Hackel, Richard P. (Livermore, CA); Paris, Robert D. (San Ramon, CA); Feldman, Mark (Pleasanton, CA)

    1993-01-01T23:59:59.000Z

    A wavelength meter having a single mode fiber optics input is disclosed. The single mode fiber enables a plurality of laser beams to be multiplexed to form a multiplexed input to the wavelength meter. The wavelength meter can provide a determination of the wavelength of any one or all of the plurality of laser beams by suitable processing. Another aspect of the present invention is that one of the laser beams could be a known reference laser having a predetermined wavelength. Hence, the improved wavelength meter can provide an on-line calibration capability with the reference laser input as one of the plurality of laser beams.

  17. Metering Best Practices: A Guide to Achieving Utility Resource...

    Broader source: Energy.gov (indexed) [DOE]

    Policy Act of 2005. mbpg.pdf More Documents & Publications Operations & Maintenance Best Practices Guide: Chapter 8 Guidance for Electric Metering in Federal Buildings...

  18. Achieving Differential Privacy of Data Disclosure in the Smart Grid

    E-Print Network [OSTI]

    Wang, Yu

    -grained usage data collection. For example, smart metering data could reveal highly accurate real-time home. Index Terms--Smart Grid, Smart Meter, Privacy, Differential Privacy, Data Disclosure I. INTRODUCTION With the rapid development of the advanced meter infras- tructure (AMI) [1] as part of a move to smart grids

  19. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    E-Print Network [OSTI]

    Darghouth, Naim Richard

    2013-01-01T23:59:59.000Z

    Study: The Economic Cost of Net-Metering in Maryland: WhoEnergy (DSIRE), 2010. Map of Net Metering Policies [WWWdocuments/summarymaps/Net_Metering_map.ppt De Jonghe, C. ,

  20. Shallow (2-meter) temperature surveys in Colorado

    SciTech Connect (OSTI)

    Zehner, Richard E.

    2012-02-01T23:59:59.000Z

    Citation Information: Originator: Geothermal Development Associates, Reno, Nevada Publication Date: 2012 Title: Colorado 2m Survey Edition: First Publication Information: Publication Place: Reno Nevada Publisher: Geothermal Development Associates, Reno, Nevada Description: Shallow temperature surveys are useful in early-stage geothermal exploration to delineate surface outflow zones, with the intent to identify the source of upwelling, usually a fault. Detailed descriptions of the 2-meter survey method and equipment design can be found in Coolbaugh et al. (2007) and Sladek et al. (2007), and are summarized here. The survey method was devised to measure temperature as far below the zone of solar influence as possible, have minimal equilibration time, and yet be portable enough to fit on the back of an all-terrain vehicle (ATV); Figure 2). This method utilizes a direct push technology (DPT) technique where 2.3 m long, 0.54Ē outer diameter hollow steel rods are pounded into the ground using a demolition hammer. Resistance temperature devices (RTD) are then inserted into the rods at 2-meter depths, and allowed to equilibrate for one hour. The temperatures are then measured and recorded, the rods pulled out of the ground, and re-used at future sites. Usually multiple rods are planted over the course of an hour, and then the sampler returns back to the first station, measures the temperatures, pulls the rods, and so on, to eliminate waiting time. At Wagon Wheel Gap, 32 rods were planted around the hot springs between June 20 and July 1, 2012. The purpose was to determine the direction of a possible upflow fault or other structure. Temperatures at 1.5m and 2m depths were measured and recorded in the attribute table of this point shapefile. Several anomalous temperatures suggest that outflow is coming from a ~N60W striking fault or shear zone that contains the quartz-fluorite-barite veins of the adjacent patented mining claims. It should be noted that temperatures at 2m depth vary according to the amount of solar heating from above, as well as possible geothermal heating from below. Spatial Domain: Extent: Top: 4490310.560635 m Left: 150307.008238 m Right: 433163.213617 m Bottom: 4009565.915398 m Contact Information: Contact Organization: Geothermal Development Associates, Reno, Nevada Contact Person: Richard ďRickĒ Zehner Address: 3740 Barron Way City: Reno State: NV Postal Code: 89511 Country: USA Contact Telephone: 775-737-7806 Spatial Reference Information: Coordinate System: Universal Transverse Mercator (UTM) WGSí1984 Zone 13N False Easting: 500000.00000000 False Northing: 0.00000000 Central Meridian: -105.00000000 Scale Factor: 0.99960000 Latitude of Origin: 0.00000000 Linear Unit: Meter Datum: World Geodetic System 1984 (WGS í1984) Prime Meridian: Greenwich Angular Unit: Degree Digital Form: Format Name: Shape file

  1. Recent developments in orifice meter and flow conditioner research

    SciTech Connect (OSTI)

    LaNasa, P.J. [CPL and Associates, Houston, TX (United States)

    1995-12-31T23:59:59.000Z

    In 1969 concerns were raised regarding the validity of the orifice meter`s coefficient of discharge uncertainty. An effort to resolve these concerns resulted in an internationally supported research project which produced a new sharp-edged concentric orifice meter empirical database and coefficient of discharge equation. However, the new empirical database and coefficient of discharge equation did not account for all of the differences being encountered in orifice metering. And in 1986, as a derivative of the coefficient of discharge equation research, questions were raised regarding the influences of installation effects on the orifice meter`s coefficient of discharge. The 1986 EC research data indicated that the flow conditioner and straight pipe installation requirements of the flow measurement standards were inadequate to prevent biasing of the orifice meter`s coefficient of discharge by flow disturbances generated from upstream piping elements. Data generated from 1990 through 1993 by GRI sponsored SWRI and NIST research confirmed the original EC biasing and further identified differential pressure tap radial position sensitivity and velocity profile and swirl angle theory deficiencies. Current research is continuing to define installation effects influences and identify possible solutions.

  2. Securing Energy Metering Software with Automatic Source Code Correction

    E-Print Network [OSTI]

    Neves, Nuno

    of energy production have been fostering the monitoring and analy- sis of electricity consumption be used for instance to store and access real-time and/or historical consumption data, plot this data and electronic electricity meters. Smart meters have processing and communication abilities, which enable novel

  3. Slide 1

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    event data * Collect asset management data AMI Technologies - How They Fit AMI Interface Smart Meter Communications Home Area Network Load Control Devices DER Smart Meter Local...

  4. Parity meter for charge qubits: an efficient quantum entangler

    E-Print Network [OSTI]

    B. Trauzettel; A. N. Jordan; C. W. J. Beenakker; M. Buttiker

    2006-04-26T23:59:59.000Z

    We propose a realization of a charge parity meter based on two double quantum dots alongside a quantum point contact. Such a device is a specific example of the general class of mesoscopic quadratic quantum measurement detectors previously investigated by Mao et al. [Phys. Rev. Lett. 93, 056803 (2004)]. Our setup accomplishes entangled state preparation by a current measurement alone, and allows the qubits to be effectively decoupled by pinching off the parity meter. Two applications of the parity meter are discussed: the measurement of Bell's inequality in charge qubits and the realization of a controlled NOT gate.

  5. Chevron facility focused on commercial orifice-meter research

    SciTech Connect (OSTI)

    Jones, E.H.; Ferguson, K.R.

    1987-07-27T23:59:59.000Z

    Research to determine the accuracy of commercial orifice meters for custody-transfer measurement has indicated that high-volume gas meters can be flow-proven while in such service. The research further yielded more accurate orifice-meter discharge coefficient equations (at Reynolds numbers greater than 4,000,000) than current equations of the International Standards Organization (ISO) and the American Petroleum Institute (API). These are partial findings of a major study conducted by Chevron Oil Field Research Co. at its Venice, La., calibration facility.

  6. Advanced monitoring of machining operations

    E-Print Network [OSTI]

    Teti, Roberto; Jemielniak, Krzysztof; O'Donnell, Garret; Dornfeld, David

    2010-01-01T23:59:59.000Z

    technology achievement; (ii) smart sensors integration; (iii) Ambient Intelligence (AmI) in manufac- turing; (iv) strengthening the European Sensor System Suppliers (SMEs)

  7. 25 years ago: the official farewell to the meter

    E-Print Network [OSTI]

    Thomas Schucker

    2008-10-20T23:59:59.000Z

    On october 21st 1983 took place in S\\`evres on the western outskirts of Paris the official funeral of the meter. With it the notion of distance as a physical observable was buried.

  8. Smart Meters Helping Oklahoma Consumers Save Hundreds During...

    Broader source: Energy.gov (indexed) [DOE]

    meters give consumers real-time information on how their energy use affects their energy costs. With a two-tiered pricing system, you get a discount during lower usage...

  9. Development Of 2-Meter Soil Temperature Probes And Results Of...

    Open Energy Info (EERE)

    Meter Soil Temperature Probes And Results Of Temperature Survey Conducted At Desert Peak, Nevada, Usa Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference...

  10. Down to the Meter: Localized Vehicle Pollution Matters

    E-Print Network [OSTI]

    Houston, Douglas; Wu, Jun; Ong, Paul; Winer, Arthur

    2006-01-01T23:59:59.000Z

    Near-Roadway Vehicle Pollution,Ē American Journal of Publicfor Vehicle-Related Air Pollution Exposure in Minority andMeter: Localized Vehicle Pollution Matters B Y D O U G L A S

  11. Smart Meters Offer 'Instant Gratification;' Help Houston Homeowners...

    Broader source: Energy.gov (indexed) [DOE]

    Diorio explains to KPRC Local 2 News how much she's saved with her recently installed smart meter, which allows her to see her savings in real time. Houston resident Ruth...

  12. Demand Response and Smart Metering Policy Actions Since the Energy...

    Broader source: Energy.gov (indexed) [DOE]

    This report represents a review of policy developments on demand response and other related areas such as smart meters and smart grid. It has been prepared by the Demand Response...

  13. LM to Meet Energy Metering Goals Through Enhanced Data Collection...

    Broader source: Energy.gov (indexed) [DOE]

    goals related to energy usage and metering. The first goal states that LM should reduce energy use intensity (EUI) by 30 percent by fiscal year (FY) 2020, as compared to the FY...

  14. NREL: Energy Storage - BLAST for Behind-the-Meter Applications...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lite (BLAST-BTM Lite) provides a quick, user-friendly tool to size behind-the-meter energy storage devices used on site by utility customers for facility demand charge...

  15. Helping New Hampshire Achieve Its 25 x 25 Goal Renewable Energy Incentives, Energy Metering, and

    E-Print Network [OSTI]

    Lotko, William

    ........................................................................ 21 5. ENERGY CONSERVATION: SMART METERING.........Helping New Hampshire Achieve Its 25 x 25 Goal Renewable Energy Incentives, Energy Metering............................................................ 12 3. RENEWABLE ENERGY: PRODUCTION INCENTIVES................................... 14 3.1 NET METERING

  16. Insights from Smart Meters: The Potential for Peak-Hour Savings from Behavior-Based Programs

    E-Print Network [OSTI]

    Todd, Annika

    2014-01-01T23:59:59.000Z

    2014. †Insights†from†Smart† Meters:†The†Potential†for†Peak†available data captured by smart meters and other sources,series Insights from Smart Meters. DRAFT Ė DO NOT CIRCULATE

  17. Metering and Calibration in LoanSTAR Buildings

    E-Print Network [OSTI]

    O'Neal, D. L.; Bryant, J. A.; Turner, W. D.; Glass, M. G.

    1990-01-01T23:59:59.000Z

    or many stories away from each other. Power measurements across multiple panels can increase costs dramatically. Buildings often have multiple electrical feeds or feed additional buildings. Asbestos is found in many chilled and hot water piping... installed before 1970. Installation of thermal metering requires asbestos abatement. The cost to remove the asbestos may be too high to justify the thermal metering. (6) Timely installation of equipment requires an intensive coordination effort during...

  18. E-Print Network 3.0 - automated seepage meters Sample Search...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    there exists less information on the mechanism An automated dye-dilution based seepage meter... , Woods Hole, Massachusetts 02543 Abstract We designed an automated seepage meter...

  19. Design and development of digital smart meter network for distribution system.

    E-Print Network [OSTI]

    Rahman, Md. M

    2011-01-01T23:59:59.000Z

    ??"The main objective of this study is to design and develop smart meter network to investigate the requirements of an efficient and reliable smart meterÖ (more)

  20. Smart-Metering for Monitoring Building Power Distribution Network using Instantaneous Phasor Computations of Electrical Signals

    E-Print Network [OSTI]

    K.R., Krishnanand

    2013-01-01T23:59:59.000Z

    Smart-Metering for Monitoring Building Power Distributionimplementable for smart-meters for a building. Eachcontrol node of a building so as to make smart decisions.

  1. Compensated count-rate circuit for radiation survey meter

    DOE Patents [OSTI]

    Todd, Richard A. (Powell, TN)

    1981-01-01T23:59:59.000Z

    A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for counting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensated circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.

  2. Compensated count-rate circuit for radiation survey meter

    DOE Patents [OSTI]

    Todd, R.A.

    1980-05-12T23:59:59.000Z

    A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for couting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensation circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.

  3. Plug-in privacy for Smart Metering billing

    E-Print Network [OSTI]

    Jawurek, Marek; Kerschbaum, Florian

    2010-01-01T23:59:59.000Z

    Smart Metering is a concept that allows to collect fine-grained consumption profiles from customers by replacing traditional electricity meters with Smart Meters in customers' households. The recorded consumption profile is the basis for the calculation of time-dependent tariffs but also allows deduction of the inhabitant's personal schedules and habits. The current reporting of such consumption profiles only protects this data from 3rd parties but falls short to protect the customer's privacy from illegitimate abuse by the supplier itself. We propose a privacy-preserving profile reporting protocol that enables billing for time-dependent tariffs without disclosing the actual data of the consumption profile to the supplier. Our approach relies on a zero-knowledge proof based on Pedersen Commitments performed by a plug-in privacy component that is put into the communication link between Smart Meter and supplier's back-end systems and requires no change to Smart Meter hardware and only little change to the softw...

  4. Net Metering and Interconnection Procedures-- Incorporating Best Practices

    SciTech Connect (OSTI)

    Jason Keyes, Kevin Fox, Joseph Wiedman, Staff at North Carolina Solar Center

    2009-04-01T23:59:59.000Z

    State utility commissions and utilities themselves are actively developing and revising their procedures for the interconnection and net metering of distributed generation. However, the procedures most often used by regulators and utilities as models have not been updated in the past three years, in which time most of the distributed solar facilities in the United States have been installed. In that period, the Interstate Renewable Energy Council (IREC) has been a participant in more than thirty state utility commission rulemakings regarding interconnection and net metering of distributed generation. With the knowledge gained from this experience, IREC has updated its model procedures to incorporate current best practices. This paper presents the most significant changes made to IREC√?¬?√?¬Ę√?¬?√?¬?√?¬?√?¬?s model interconnection and net metering procedures.

  5. Microwave Pickup on the Crawford Hill 7-meter Jeff McMahon

    E-Print Network [OSTI]

    Microwave Pickup on the Crawford Hill 7-meter Telescope Jeff McMahon Project Advisor: Suzanne-Meter Telescope The Crawford Hill 7-meter telescope located at Bell labs in Holmdel, New Jersey is being considered for use in the CapMAP project. This antenna is a 7-meter offset Cassegrain reflector antenna

  6. EVALUATING EFFECTIVENESS OF RAMP Evidence from the twin cities ramp meter shut-off

    E-Print Network [OSTI]

    Levinson, David M.

    Chapter 9 EVALUATING EFFECTIVENESS OF RAMP METERS Evidence from the twin cities ramp meter shut-625-6354 Abstract: Ramp meters in the Twin Cities have been turned off for eight weeks in Fall 2000 in an experiment representative freeways during the afternoon peak period. Several performance measures for ramp metering

  7. Active fault creep variations at Chihshang, Taiwan, revealed by creep meter monitoring, 19982001

    E-Print Network [OSTI]

    Lee, Jian-Cheng

    Active fault creep variations at Chihshang, Taiwan, revealed by creep meter monitoring, 1998] The daily creep meter data recorded at Chihshang in 1998­2001 are presented. The Chihshang creep meter similar annual shortening rates: 16.2 mm at the Tapo site (comprising two connected creep meters) and 15

  8. Differentially Private Smart Metering with Battery Michael Backes1,2

    E-Print Network [OSTI]

    Differentially Private Smart Metering with Battery Recharging Michael Backes1,2 and Sebastian meters to take fine-grained readings of energy usage. These smart meters enable flexible time- of to a min- imum. 1 Introduction The energy industry has recently begun using smart meters to take fine

  9. P\\procedure\\EU#7 Page 1 of 2 TITLE: PROCEDURE FOR RECORDING AND TRANSMITTING METER READINGS

    E-Print Network [OSTI]

    Fernandez, Eduardo

    P\\procedure\\EU#7 Page 1 of 2 TITLE: PROCEDURE FOR RECORDING AND TRANSMITTING METER READINGS FOR NEW METER SETS, METER REPLACEMENTS AND WHEN THE ACCOUNTABILITY FOR THE METERS USAGE CHANGES OBJECTIVE AND PURPOSE: To provide a timely and accurate method of capturing meter readings when a meter is changed out

  10. Entropy Meters and the Entropy of Non-extensive Systems

    E-Print Network [OSTI]

    Elliott H. Lieb; Jakob Yngvason

    2014-03-30T23:59:59.000Z

    In our derivation of the second law of thermodynamics from the relation of adiabatic accessibility of equilibrium states we stressed the importance of being able to scale a system's size without changing its intrinsic properties. This leaves open the question of defining the entropy of macroscopic, but unscalable systems, such as gravitating bodies or systems where surface effects are important. We show here how the problem can be overcome, in principle, with the aid of an `entropy meter'. An entropy meter can also be used to determine entropy functions for non-equilibrium states and mesoscopic systems.

  11. Testing the 2-element 4-wire delta watthour meter

    E-Print Network [OSTI]

    Grasshoff, Lynn Howard

    1950-01-01T23:59:59.000Z

    G THE 2-ELE!KHT $&&ZRE DELTA VATTHSUR METER A Thesis Suboitted to the Faculty of' the Agricultural and Mechanical College of Texas in Part:"':ulfl1nent of j. ho Rsquiransnto for th- Degree of Master o Science Ma)or Sub]sets Electrical Enginosring... Bv Lynn Hovard Grasshof f Juno l'-J)Q LCKNOWLEDCd~T The author wishes to express his appreciation to llr. M. C. Fowler& ltxnager& Southwestern District, Bangamo Electric Company, i' or making available the neoessary test equipment, meters...

  12. Connector-induced offsets in optical fiber power meters

    SciTech Connect (OSTI)

    Vayshenker, Igor; Li Xiaoyu; Keenan, Darryl A

    2006-08-20T23:59:59.000Z

    We discuss issues related to calibration of optical fiber power meters. The power readings may vary when using various types of fiber connectors, or even the same type of connectors made by different vendors. We study the connector effects by calibrating four types of optical fiber power meters using six different fiber connectors from four vendors at three wavelengths. We found variations of as much as 12% due to the different reflection properties of the detector windows, connectors, and detectors. We also compared connector measurement results with the data obtained by using open beams.

  13. Commercial Buildings Partnership Projects - Metered Data Format and Delivery

    SciTech Connect (OSTI)

    Katipamula, Srinivas

    2010-11-16T23:59:59.000Z

    A number of the Commercial Building Partnership Projects (CBPs) will require metering, monitoring, data analysis and verification of savings after the retrofits are complete. Although monitoring and verification (M&V) agents are free to use any metering and monitoring devices that they chose, the data they collect should be reported to Pacific Northwest National Laboratory (PNNL) in a standard format. PNNL will store the data collected in its CBP database for further use by PNNL and U.S. Department of Energy. This document describes the data storage process and the deliver format of the data from the M&V agents.

  14. E-Print Network 3.0 - advanced methods properties Sample Search...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    EXCELLENTIA CoLumbIA ENgINEErINg290 Summary: on the nanoscale--one-billionth of a meter. Aron Pinczuk's research projects employ advanced optics methods... --be they...

  15. 1. From the Mail Services website, (www.princeton.edu/mail) click on Metered Mail to access the Meter Request Form.

    E-Print Network [OSTI]

    Singh, Jaswinder Pal

    1. From the Mail Services website, (www.princeton.edu/mail) click on Metered Mail to access the Meter Request Form. 2. Log in using your Princeton NetID and password. The system will pre the drop-down menu. To enter a new chartstring, click "Create New." Online Meter Request Form A step

  16. Note: A real-time beam current density meter

    SciTech Connect (OSTI)

    Liu Junliang; Yu Deyang; Ruan Fangfang; Xue Yingli; Wang Wei [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China)

    2013-03-15T23:59:59.000Z

    We have developed a real-time beam current density meter for charged particle beams. It measures the mean current density by collimating a uniform and large diameter primary beam. The suppression of the secondary electrons and the deflection of the beam were simulated, and it was tested with a 105 keV Ar{sup 7+} ion beam.

  17. The Statewide Benefits Of Net-Metering In California

    E-Print Network [OSTI]

    Kammen, Daniel M.

    on the costs and benefits of NEM to the Governor and Legislature. 4 Id. 5 California Solar Future: Growing to the total, "bundled" energy rate, which includes not only the cost of generation, but transmission of 2013 3 See Net Energy Metering Cost-Effectiveness Evaluation, Energy and Environmental Economics, Inc

  18. ParkingMeter: Balancing Energy Savings and Service Availability

    E-Print Network [OSTI]

    Kravets, Robin

    ParkingMeter: Balancing Energy Savings and Service Availability Riccardo Crepaldi University of Illinois at Urbana Champaign rcrepal2@illinois.edu Ryan Welsh University of Illinois at Urbana Champaign rjwelsh2@illinois.edu Robin H. Kravets University of Illinois at Urbana Champaign rhk@illinois

  19. Personal energy metering Simon Hay, Andrew Rice and Andy Hopper

    E-Print Network [OSTI]

    Cambridge, University of

    based on energy and usage data collected over the course of a year. We also studied the addi- tionalPersonal energy metering Simon Hay, Andrew Rice and Andy Hopper {sjeh3,acr31,ah12}@cam.ac.uk Computer Laboratory, University of Cambridge 1 Introduction Every day each of us consumes a significant

  20. Privacy-friendly Energy-metering via Homomorphic Encryption

    E-Print Network [OSTI]

    Jacobs, Bart

    Privacy-friendly Energy-metering via Homomorphic Encryption Flavio D. Garcia and Bart Jacobs and consumption is one of the goals. Accurate usage data is important for such a better match. So-called smart by the utility sector. For instance, in April 2009 the Senate in the Netherlands has refused to pass a bill

  1. Hydrostatic bearings for a turbine fluid flow metering device

    DOE Patents [OSTI]

    Fincke, J.R.

    1982-05-04T23:59:59.000Z

    A rotor assembly fluid metering device has been improved by development of a hydrostatic bearing fluid system which provides bearing fluid at a common pressure to rotor assembly bearing surfaces. The bearing fluid distribution system produces a uniform film of fluid between bearing surfaces and allows rapid replacement of bearing fluid between bearing surfaces, thereby minimizing bearing wear and corrosion. 3 figs.

  2. Hydrostatic bearings for a turbine fluid flow metering device

    DOE Patents [OSTI]

    Fincke, James R. (Rigby, ID)

    1982-01-01T23:59:59.000Z

    A rotor assembly fluid metering device has been improved by development of a hydrostatic bearing fluid system which provides bearing fluid at a common pressure to rotor assembly bearing surfaces. The bearing fluid distribution system produces a uniform film of fluid between bearing surfaces and allows rapid replacement of bearing fluid between bearing surfaces, thereby minimizing bearing wear and corrosion.

  3. AMIE (ARM MJO Investigation Experiment): Observations of the Madden-Julian Oscillation for Modeling Studies Science Plan

    SciTech Connect (OSTI)

    Long, C; Del Genio, A; Gustafson, W; Houze, R; Jakob, C; Jensen, M; Klein, S; Leung, L Ruby; Liu, X; Luke, E; May, P; McFarlane, S; Minnis, P; Schumacher, C; Vogelmann, A; Wang, Y; Wu, X; Xie, S

    2010-03-22T23:59:59.000Z

    Deep convection in the tropics plays an important role in driving global circulations and the transport of energy from the tropics to the mid-latitudes. Understanding the mechanisms that control tropical convection is a key to improving climate modeling simulations of the global energy balance. One of the dominant sources of tropical convective variability is the Madden-Julian Oscillation (MJO), which has a period of approximately 30Ė60 days. There is no agreed-upon explanation for the underlying physics that maintain the MJO. Many climate models do not show well-defined MJO signals, and those that do have problems accurately simulating the amplitude, propagation speed, and/or seasonality of the MJO signal. Therefore, the MJO is a very important modeling target for the ARM modeling community geared specifically toward improving climate models. The ARM MJO Investigation Experiment (AMIE) period coincides with a large international MJO initiation field campaign called CINDY2011 (Cooperative Indian Ocean experiment on intraseasonal variability in the Year 2011) that will take place in and around the Indian Ocean from October 2011 to January 2012. AMIE, in conjunction with CINDY2011 efforts, will provide an unprecedented data set that will allow investigation of the evolution of convection within the framework of the MJO. AMIE observations will also complement the long-term MJO statistics produced using ARM Manus data and will allow testing of several of the current hypotheses related to the MJO phenomenon. Taking advantage of the expected deployment of a C-POL scanning precipitation radar and an ECOR surface flux tower at the ARM Manus site, we propose to increase the number of sonde launches to eight per day starting in about mid-October of the field experiment year, which is climatologically a period of generally suppressed conditions at Manus and just prior to the climatologically strongest MJO period. The field experiment will last until the end of the MJO season (typically March), affording the documentation of conditions before, during, and after the peak MJO season. The increased frequency of sonde launches throughout the experimental period will provide better diurnal understanding of the thermodynamic profiles, and thus a better representation within the variational analysis data set. Finally, a small surface radiation and ceilometer system will be deployed at the PNG Lombrum Naval Base about 6 km away from the ARM Manus site in order to provide some documentation of scale variability with respect to the representativeness of the ARM measurements.

  4. Soil pH and the Home Landscape or Garden 1 Amy L. Shober, Christine Wiese, and Geoffrey C. Denny2

    E-Print Network [OSTI]

    Jawitz, James W.

    SL 256 Soil pH and the Home Landscape or Garden 1 Amy L. Shober, Christine Wiese, and Geoffrey C. Denny2 1. This document is SL 256, one of a series of the Soil and Water Science Department, Florida. Shober, assistant professor, Soil and Water Science Department, Gulf Coast Research and Education Center

  5. Poverty of the Stimulus? A Rational Approach Amy Perfors1 (perfors@mit.edu), Joshua B. Tenenbaum1 (jbt@mit.edu),

    E-Print Network [OSTI]

    Tenenbaum, Josh

    Poverty of the Stimulus? A Rational Approach Amy Perfors1 (perfors@mit.edu), Joshua B. Tenenbaum1, MIT; 2 Department of Psychology, University of Chicago Abstract The Poverty of the Stimulus (Po that these generalizations can best be explained by innate knowledge, known as the argument from the Poverty of the Stimulus

  6. Proceedings of Power Systems 03: Distributed Generation and Advanced Metering 2002 Wichita State University

    E-Print Network [OSTI]

    Pressure Natural Gas CNG Compressed Natural Gas L/HHV Low /High Heating Value SCFM Standard Cubic Feet per

  7. Dead-time compensation for a logarithmic display rate meter

    DOE Patents [OSTI]

    Larson, John A. (Aurora, IL); Krueger, Frederick P. (Aurora, IL)

    1988-09-20T23:59:59.000Z

    An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events.

  8. Clustering of Meter-wave Luminous Objects toward Monoceros

    E-Print Network [OSTI]

    Shuji Deguchi; Kazutaka Koike

    2008-11-19T23:59:59.000Z

    A distribution of the meter-wave luminous objects, which are bright at frequency 74 MHz (a wavelength of 4 m) but not detectable at 1.4 GHz (21 cm) in the VLA surveys, shows a notable concentration in a scale of a few degrees toward Monoceros [(l, b)=(225, 4)]. We argue that it is a part of giant radio relics associated with a nearby cluster of galaxies with cz~2400$ km s^{-1} centered on the spiral galaxy NGC 2377. The angular separation of these objects from the clustering center is consistent with the separation of distant relics to the cluster center if scaled by distance. This fact implies that the concentrations of meter-wave luminous objects can be used as a tracer of the structure of the Local Supercluster and it's vicinity.

  9. Dead-time compensation for a logarithmic display rate meter

    DOE Patents [OSTI]

    Larson, J.A.; Krueger, F.P.

    1987-10-05T23:59:59.000Z

    An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events. 5 figs.

  10. Smart Meter Privacy: A Utility-Privacy Framework

    E-Print Network [OSTI]

    Rajagopalan, S Raj; Mohajer, Soheil; Poor, H Vincent

    2011-01-01T23:59:59.000Z

    End-user privacy in smart meter measurements is a well-known challenge in the smart grid. The solutions offered thus far have been tied to specific technologies such as batteries or assumptions on data usage. Existing solutions have also not quantified the loss of benefit (utility) that results from any such privacy-preserving approach. Using tools from information theory, a new framework is presented that abstracts both the privacy and the utility requirements of smart meter data. This leads to a novel privacy-utility tradeoff problem with minimal assumptions that is tractable. Specifically for a stationary Gaussian Markov model of the electricity load, it is shown that the optimal utility-and-privacy preserving solution requires filtering out frequency components that are low in power, and this approach appears to encompass most of the proposed privacy approaches.

  11. Hydrostatic bearings for a turbine fluid flow metering device

    DOE Patents [OSTI]

    Fincke, J.R.

    1980-05-02T23:59:59.000Z

    A rotor assembly fluid metering device has been improved by development of a hydrostatic bearing fluid system which provides bearing fluid at a common pressure to rotor assembly bearing surfaces. The bearing fluid distribution system produces a uniform film of fluid distribution system produces a uniform film of fluid between bearing surfaces and allows rapid replacement of bearing fluid between bearing surfaces, thereby minimizing bearing wear and corrosion.

  12. Naval Undersea Warfare Center Division Newport utilities metering, Phase 1

    SciTech Connect (OSTI)

    Carroll, D.M.

    1992-11-01T23:59:59.000Z

    Pacific Northwest Laboratory developed this report for the US Navy's Naval Undersea Warfare Center Division Newport, Rhode Island (NUWC). The purpose of the report was to review options for metering electricity and steam used in the NUWC compound, and to make recommendations to NUWC for implementation under a follow-on project. An additional NUWC concern is a proposed rate change by the servicing utility, Newport Electric, which would make a significant shift from consumption to demand billing, and what effect that rate change would have on the NUWC utility budget. Automated, remote reading meters are available which would allow NUWC to monitor its actual utility consumption and demand for both the entire NUWC compound and by end-use in individual buildings. Technology is available to perform the meter reads and manipulate the data using a personal computer with minimal staff requirement. This is not meant to mislead the reader into assuming that there is no requirement for routine preventive maintenance. All equipment requires routine maintenance to maintain its accuracy. While PNL reviewed the data collected during the site visit, however, it became obvious that significant opportunities exist for reducing the utility costs other than accounting for actual consumption and demand. Unit costs for both steam and electricity are unnecessarily high, and options are presented in this report for reducing them. Additionally, NUWC has an opportunity to undertake a comprehensive energy resource management program to significantly reduce its energy demand, consumption, and costs.

  13. Naval Undersea Warfare Center Division Newport utilities metering, Phase 1

    SciTech Connect (OSTI)

    Carroll, D.M.

    1992-11-01T23:59:59.000Z

    Pacific Northwest Laboratory developed this report for the US Navy`s Naval Undersea Warfare Center Division Newport, Rhode Island (NUWC). The purpose of the report was to review options for metering electricity and steam used in the NUWC compound, and to make recommendations to NUWC for implementation under a follow-on project. An additional NUWC concern is a proposed rate change by the servicing utility, Newport Electric, which would make a significant shift from consumption to demand billing, and what effect that rate change would have on the NUWC utility budget. Automated, remote reading meters are available which would allow NUWC to monitor its actual utility consumption and demand for both the entire NUWC compound and by end-use in individual buildings. Technology is available to perform the meter reads and manipulate the data using a personal computer with minimal staff requirement. This is not meant to mislead the reader into assuming that there is no requirement for routine preventive maintenance. All equipment requires routine maintenance to maintain its accuracy. While PNL reviewed the data collected during the site visit, however, it became obvious that significant opportunities exist for reducing the utility costs other than accounting for actual consumption and demand. Unit costs for both steam and electricity are unnecessarily high, and options are presented in this report for reducing them. Additionally, NUWC has an opportunity to undertake a comprehensive energy resource management program to significantly reduce its energy demand, consumption, and costs.

  14. Design of high pressure metering and regulating stations

    SciTech Connect (OSTI)

    Rehler, D.A. [Oklahoma Natural Gas Co., Enid, OK (United States)

    1995-12-01T23:59:59.000Z

    Metering and regulating stations effectively serve as the cash registers of the natural gas industry. While the potential for lost revenue resulting from improper design is a serious consideration, it is not the only one. The potential exists for problems such as excessive noise levels, inaccurate reflection of lost and unaccounted-for gas, and numerous potentially hazardous situations. The best time to limit the potential for problems is during the design process. This, together with the critical nature of these stations, dictates that proper design is imperative. Proper design of metering and regulating stations is a constantly changing and extremely complicated subject. There are virtually an infinite number of situations that the designer can encounter in evaluating his design. In view of this, it is impossible to develop a cookbook method of designing these stations that covers all possible situations. The emphasis of this paper is to briefly touch on the major aspects of metering and regulating station design. Steps involved in station design are: 1. Collection of data on the proposed station. 2. Determination of piping configuration. 3. Selection of measurement equipment. 4. Selection of pressure regulating and overpressure protection equipment. 5. Communication of the final design to field personnel.

  15. 100 Meter Time of Flight System for Transmission Experiments Michael Rapp, Yaron Danon, Robert Block

    E-Print Network [OSTI]

    Danon, Yaron

    100 Meter Time of Flight System for Transmission Experiments Michael Rapp, Yaron Danon, Robert of the detectors was chosen to take advantage of the neutron beam geometry at the detector location, 100 meters

  16. E-Print Network 3.0 - automatic survey meter Sample Search Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    at Amherst Collection: Environmental Sciences and Ecology 5 An Agent Based Simulation of Smart Metering TechnologyAdoption Summary: on the utility, to a 12;high-technology meter...

  17. How Would You Use a Smart Meter to Manage Your Energy Use? |...

    Broader source: Energy.gov (indexed) [DOE]

    Would You Use a Smart Meter to Manage Your Energy Use? How Would You Use a Smart Meter to Manage Your Energy Use? May 19, 2011 - 7:30am Addthis On Monday, Andrea told you about...

  18. Feasibility of the design of dual-lane ramp meters in Texas

    E-Print Network [OSTI]

    Butorac, Marc Allen

    2012-06-07T23:59:59.000Z

    As recurrent congestion and the number of vehicles on urban freeways in Texas have increased, the ability to effectively meter traffic using single-lane ramp meters has deteriorated. Other state departments of transportation experiencing similar...

  19. 1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. HIGH-ACCURACY LASER POWER AND ENERGY METER CALIBRATION SYSTEM . . . . . . . . 2

    E-Print Network [OSTI]

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. HIGH-ACCURACY LASER POWER AND ENERGY METER CALIBRATION SYSTEM . . . . . . . . 2 2.1 Calibration

  20. Video game console usage and national energy consumption: Results from a field-metering study

    E-Print Network [OSTI]

    Desroches, Louis-Benoit

    2013-01-01T23:59:59.000Z

    with their free energy audit program. Meters were installedinstalled as part of an energy audit program. Users may be

  1. Status of Net Metering: Assessing the Potential to Reach Program Caps (Poster)

    SciTech Connect (OSTI)

    Heeter, J.; Bird, L.; Gelman, R.

    2014-10-01T23:59:59.000Z

    Several states are addressing the issue of net metering program caps, which limit the total amount of net metered generating capacity that can be installed in a state or utility service territory. In this analysis, we examine net metering caps to gain perspective on how long net metering will be available in various jurisdictions under current policies. We also surveyed state practices and experience to understand important policy design considerations.

  2. Status of Net Metering: Assessing the Potential to Reach Program Caps

    SciTech Connect (OSTI)

    Heeter, J.; Gelman, R.; Bird, L.

    2014-09-01T23:59:59.000Z

    Several states are addressing the issue of net metering program caps, which limit the total amount of net metered generating capacity that can be installed in a state or utility service territory. In this analysis, we examine net metering caps to gain perspective on how long net metering will be available in various jurisdictions under current policies. We also surveyed state practices and experience to understand important policy design considerations.

  3. United States- Land Based and Offshore Annual Average Wind Speed at 100 Meters

    Broader source: Energy.gov [DOE]

    Full-size, high resolution version of the 100-meter land-based and offshore wind speed resource map.

  4. Effects of geometric scaling on static pressure measurements in orifice flow-meters

    E-Print Network [OSTI]

    Sarker, Arunava

    2012-06-07T23:59:59.000Z

    . (Mech) University of Mysore, India Chair of Advisory Committee: Dr. G. L. Morrison It is estimated that there are over one million orifice meters in operation today in the United States of America. . The accuracy of these meters.... It is estimated that there are over one million orifice meters in operation today in the United States of America. The accuracy of these meters is such that uncertainties of millions of dollars a year result from their use [1]. The basic idea employed...

  5. Missing Data Handling for Meter Data Management System Ru-Sen Jeng1

    E-Print Network [OSTI]

    Chen, Ling-Jyh

    Missing Data Handling for Meter Data Management System Ru-Sen Jeng1 , Chien-Yu Kuo1 , Yao-hua Ho1, Academia Sinica ABSTRACT We study the meter data management systems (MDMS) with a fo- cus on missing data meter data manage- ment systems. Categories and Subject Descriptors H.4.2 [Information Systems

  6. Meter as Mechanism: A Neural Network that Learns Metrical Michael Gasser, Douglas Eck and Robert Port

    E-Print Network [OSTI]

    Gasser, Michael

    Meter as Mechanism: A Neural Network that Learns Metrical Patterns Michael Gasser, Douglas Eck that apparently underlies both music and some examples of speech production is meter. Yet detailed measurements of pulses that conform to particular meters. In addition, beginning with an initial state with no biases

  7. Feeling Music: Integration of Auditory and Tactile Inputs in Musical Meter Perception

    E-Print Network [OSTI]

    Wang, Xiaoqin

    Feeling Music: Integration of Auditory and Tactile Inputs in Musical Meter Perception Juan Huang1 are integrated in humans performing a musical meter recognition task. Subjects discriminated between two types coherent meter percepts, and 3) Simultaneously presented bimodal inputs where the two channels contained

  8. Detecting Meter in Recorded Music Joseph E. Flannick, Rachel W. Hall, and Robert Kelly

    E-Print Network [OSTI]

    Hall, Rachel W.

    Detecting Meter in Recorded Music Joseph E. Flannick, Rachel W. Hall, and Robert Kelly Dept) to identify the primary rhythmic content of pieces of popular music. The meter of such pieces is deter- mined of energy bursts in each band. We found that the meters of the pieces we analyzed were characterized

  9. Broadband precision wavelength meter based on a stepping FabryProt interferometer

    E-Print Network [OSTI]

    Rehse, Steven J.

    Broadband precision wavelength meter based on a stepping Fabry­Pérot interferometer T. J. Scholl. INTRODUCTION Wavelength meters based on Michelson or Fizeau inter- ferometers have long been the standard a more general laser wavelength meter in which the FP ring pattern was employed to compare

  10. Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal Dutta

    E-Print Network [OSTI]

    Dutta, Prabal

    Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal}@eecs.umich.edu culler@cs.berkeley.edu Abstract AC power meters require both voltage and current to be sampled physical proximity and fed into a single power metering de- vice. In this paper, we explore the viability

  11. Behavioral/Systems/Cognitive Selective Neuronal Entrainment to the Beat and Meter

    E-Print Network [OSTI]

    Behavioral/Systems/Cognitive Selective Neuronal Entrainment to the Beat and Meter Embedded Fundamental to the experience of music, beat and meter perception refers to the perception of periodicities the spontaneous building of beat and meter hypothesized to emerge from the selective entrainment of neuronal

  12. Metering Plan: Monitoring Energy and Potable Water Use in PNNL EMS4 Buildings

    SciTech Connect (OSTI)

    Pope, Jason E.

    2012-07-25T23:59:59.000Z

    This Plan presents progress toward the metering goals shared by all national laboratories and discusses PNNL's contemporary approach to the installation of new meters. In addition, the Plan discusses the data analysis techniques with which PNNL is working to mature using endless data streams made available as a result of increased meter deployment.

  13. RIS-M-2243 THE RADIOCHROMIC DYE FILM DOSE METER AS A POSSIBLE TEST OF PARTICLE

    E-Print Network [OSTI]

    RIS√?-M-2243 THE RADIOCHROMIC DYE FILM DOSE METER AS A POSSIBLE TEST OF PARTICLE TRACK THEORY Johnny-film radlochromlc dye cyanide plastic dose meter to Ionizing radiation of electrons and heavy charged particles - 1. INTRODUCTION The radiochromic dye cyanide film dose meter has been investigated as a pos- sible

  14. TRACKING THE "ODD": METER INFERENCE IN A CULTURALLY DIVERSE MUSIC CORPUS

    E-Print Network [OSTI]

    TRACKING THE "ODD": METER INFERENCE IN A CULTURALLY DIVERSE MUSIC CORPUS Andre Holzapfel New York, containing a variety of meter types. We demonstrate that by adapting the model to specific styles, we can track beats and down- beats in odd meter types like 9/8 or 7/8 with an accuracy significantly improved

  15. C-Meter: A Framework for Performance Analysis of Computing Clouds

    E-Print Network [OSTI]

    Iosup, Alexandru

    C-Meter: A Framework for Performance Analysis of Computing Clouds Nezih Yigitbasi, Alexandru Iosup virtualization and network communications overheads. To address these issues, we have designed and implemented C-Meter of computing clouds. Then, we present the architecture of the C-Meter framework and discuss several resource

  16. Too expensive to meter: The influence of transaction costs in transportation and

    E-Print Network [OSTI]

    Odlyzko, Andrew M.

    Too expensive to meter: The influence of transaction costs in transportation and communication in their homes electrical energy too cheap to meter, ... It is not too much to expect that our children will know to age. Strauss' expression "too cheap to meter" has entered the lexicon as a catch

  17. Infants Prefer the Musical Meter of Their Own Culture: A Cross-Cultural Comparison

    E-Print Network [OSTI]

    Ahmad, Sajjad

    Infants Prefer the Musical Meter of Their Own Culture: A Cross-Cultural Comparison Gaye Soley to determine whether cultural background would influence their preferences for musical meter. In Experiment 1, American infants preferred Western over Balkan meter, whereas Turkish infants, who were familiar with both

  18. DESIGN OF INTELLIGENT CONDUCTIVITY METER BASED ON MSP430F149

    E-Print Network [OSTI]

    DESIGN OF INTELLIGENT CONDUCTIVITY METER BASED ON MSP430F149 Yaoguang Wei, Jianqing Wang, Daoliang are agriculture information technology. dliangl@cau.edu.cn Abstract: An intelligent conductivity meter based on MSP430F149 microcontroller was proposed in this paper. The intelligent conductive meter was composed

  19. DEVELOPMENT OF ONE METER-LONG LITHIUM PLASMA SOURCE AND EXCIMER MODE REDUCTION FOR PLASMA WAKEFIELD

    E-Print Network [OSTI]

    DEVELOPMENT OF ONE METER-LONG LITHIUM PLASMA SOURCE AND EXCIMER MODE REDUCTION FOR PLASMA WAKEFIELD 94720 K. Marsh, P. Muggli, S. Wang, and C. Joshi, UCLA, Los Angeles, CA 90024 Abstract A one meter long reduction. 1 INTRODUCTION A one-meter long plasma source has been constructed which will permit

  20. Neighborhood Watch: Security and Privacy Analysis of Automatic Meter Reading Systems

    E-Print Network [OSTI]

    Xu, Wenyuan

    Neighborhood Watch: Security and Privacy Analysis of Automatic Meter Reading Systems Ishtiaq Rouf gruteser@winlab.rutgers.edu ABSTRACT Research on smart meters has shown that fine-grained en- ergy usage data poses privacy risks since it allows inferences about activities inside the home. While smart meter

  1. Finding Meter in Music Using an Autocorrelation Phase Matrix and Shannon Douglas Eck

    E-Print Network [OSTI]

    Eck, Doug

    Finding Meter in Music Using an Autocorrelation Phase Matrix and Shannon Entropy Douglas Eck. This approach yields a good model for predicting the meter of a piece of music. Finally we can use the phase information in the matrix to align a can- didate meter with music, making it possible to perform beat

  2. meters in CO2 euthanasia chambers. All CO2 euthanasia chambers in both

    E-Print Network [OSTI]

    Bushman, Frederic

    meters in CO2 euthanasia chambers. All CO2 euthanasia chambers in both the facilities and laboratories will need flow meters. ULAR is currently in the process of identifying a cost-effective, accurate, and durable flow meter to install in all of the CO2 chambers in all of the vivaria. When a specific model

  3. A Scalable Soft Spot Analysis Methodology for Compound Noise Effects in Nano-meter Circuits

    E-Print Network [OSTI]

    California at San Diego, University of

    A Scalable Soft Spot Analysis Methodology for Compound Noise Effects in Nano-meter Circuits Chong@ece.ucsd.edu ABSTRACT Circuits using nano-meter technologies are becoming increasingly vulnerable to signal interference methodology to study the vulnerability of digital ICs exposed to nano-meter noise and transient soft errors

  4. Principle and implementations of a refracto-nephelo-turbidi-meter for

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    1 Principle and implementations of a refracto-nephelo-turbidi-meter for seawater measurements B of physical oceanography requires a compact high-resolution in-situ salino-turbidi-meter to measure these two the requirements and challenges of refracto-turbidi-meter design from their measurement principles and correlations

  5. Design study of 8 meter monolithic mirror UV/optical space telescope H. Philip Stahl

    E-Print Network [OSTI]

    Sirianni, Marco

    Design study of 8 meter monolithic mirror UV/optical space telescope H. Philip Stahl NASA Marshall Space Flight Center, Huntsville, AL 35812 ABSTRACT The planned Ares V launch vehicle with its 10 meter to 8 meter class monolithic primary mirror telescope to Sun-Earth L2 using an Ares V. Specific

  6. Behavioral/Systems/Cognitive Tagging the Neuronal Entrainment to Beat and Meter

    E-Print Network [OSTI]

    Behavioral/Systems/Cognitive Tagging the Neuronal Entrainment to Beat and Meter Sylvie Nozaradan,1 (BRAMS), Universite¬ī de Montre¬īal, Quebec C.P. 6128 H3C 3J7, Canada Feeling the beat and meter to the beat frequency. Most importantly, we found that meter imagery elicits an additional frequency tuned

  7. A model of the VU (volume-unit) meter, with speech applications Bryce Lobdell

    E-Print Network [OSTI]

    Allen, Jont

    A model of the VU (volume-unit) meter, with speech applications Bryce Lobdell Jont Allen Beckman Institute, University of Illinois Urbana, IL 61801 (October 11, 2006) Running title: volume unit meter usage ABSTRACT The Volume Unit (VU) meter, used in speech research prior to the ad- vent of computers and modern

  8. Gemini: A Non-Invasive, Energy-Harvesting True Power Meter Bradford Campbell and Prabal Dutta

    E-Print Network [OSTI]

    Dutta, Prabal

    Gemini: A Non-Invasive, Energy-Harvesting True Power Meter Bradford Campbell and Prabal Dutta,prabal}@umich.edu Abstract--Power meters are critical for submetering loads in residential and commercial settings, but high by proposing non-invasive meters that easily clip onto a wire, or stick onto a circuit breaker, to perform

  9. Too expensive to meter: The influence of transaction costs in transportation and

    E-Print Network [OSTI]

    Odlyzko, Andrew M.

    Too expensive to meter: The influence of transaction costs in transportation and communication to meter, ... It is not too much to expect that our children will know of great periodic regional famines to meter'' has entered the lexicon as a catch­phrase for technological promises that have gone unfulfilled

  10. Reference Directions for a Sound Level Meter , M.R. Vaabenb

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    0 and 90 Reference Directions for a Sound Level Meter E. Aflaloa , M.R. Vaabenb , P. Pourtaua , D the requirements of the IEC 61672 standard on sound level meters taking into account noise incidence from level meter must be pointed at the source according to standard IEC 60651. The purpose of the paper

  11. Evaluating Government's Policies on Promoting Smart Metering Diffusion in Retail Electricity Markets via

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    Evaluating Government's Policies on Promoting Smart Metering Diffusion in Retail Electricity on promoting smart metering in the U.K. retail electricity market. We break down the policy into four possible recommendations for the energy mar- ket is the adoption of smart metering technology, which, in addition

  12. eMeter: An interactive energy monitor In this work, we propose an interactive load monitoring

    E-Print Network [OSTI]

    level. Therefore, we extended the capabilities of a smart elec- tricity meter and developed a mobile interfaces Merging smart meters and mobile devices Timely consumption feedback and guidance with re- spectComp 2009, Sep 30 ­ Oct 3, 2009, Orlando, FL, USA #12;household once smart meters are introduced. We wanted

  13. A Distortion-Theoretic Perspective for Redundant Metering Security in a Smart Grid

    E-Print Network [OSTI]

    Kundur, Deepa

    A Distortion-Theoretic Perspective for Redundant Metering Security in a Smart Grid Mustafa El--In a smart grid environment some customers employ third-party meters and terminals for integrity verification of the smart meter power measurements reported by the electric utility company. We address the security issues

  14. VentureBeat Smart meters could breathe life into flagging chip market

    E-Print Network [OSTI]

    Lu, Chenyang

    VentureBeat Smart meters could breathe life into flagging chip market April 1, 2009 | Camille Ricketts Even as the downturn dries up cleantech capital, smart-meter makers continue to do quite well, and major utilities like PG&E jumping on board, it looks like the smart-meter industry will hold strong

  15. AgSec: Secure and Efficient CDMA-based Aggregation for Smart Metering Systems

    E-Print Network [OSTI]

    Namboodiri, Vinod

    AgSec: Secure and Efficient CDMA-based Aggregation for Smart Metering Systems Navid Alamatsaz-based data aggregation method provides access to all the data of all the smart meters in the root node, which in this case is the Utility Center, while keeping the smart metering data secure. The efficiency

  16. SMART METER PRIVACY USING A RECHARGEABLE BATTERY: MINIMIZING THE RATE OF INFORMATION LEAKAGE

    E-Print Network [OSTI]

    Khisti, Ashish

    SMART METER PRIVACY USING A RECHARGEABLE BATTERY: MINIMIZING THE RATE OF INFORMATION LEAKAGE David. INTRODUCTION Deployments of smart electricity meters to residential homes con- tinue unabated around the world resources. Smart meters are essential to coordinate the desired charging and discharg- ing of the batteries

  17. Designing Privacy-preserving Smart Meters with Low-cost Microcontrollers

    E-Print Network [OSTI]

    Shenoy, Prashant

    Designing Privacy-preserving Smart Meters with Low-cost Microcontrollers Andres Molina Microsoft Research Cambridge Abstract. Smart meters that track fine-grained electricity usage and implement smart meter deployment is that fine-grained usage data indirectly reveals detailed information about

  18. Tracking States of Massive Electrical Appliances by Lightweight Metering and Sequence Decoding

    E-Print Network [OSTI]

    Wang, Yongcai

    to track the on/off states of N appliances by deploying only m smart meters on the power load tree, where m demonstrate some interesting structures of the problem. Keywords Energy auditing, Smart meter, Deployment smart meter networks, and thus suffer from the high deploy- ment, maintenance and data collection costs

  19. Social Network of Smart-Metered Homes and SMEs for Grid-based Renewable Energy Exchange

    E-Print Network [OSTI]

    Steels, Luc

    Social Network of Smart-Metered Homes and SMEs for Grid-based Renewable Energy Exchange Ioana G system on top of smart metering and social web technologies. This is achieved using a framework to connect dynamic, context-aware, heterogeneous virtual and real entities on the Internet of Smart Meters

  20. The Coldest Cubic Meter in the Known Universe

    E-Print Network [OSTI]

    Jonathan Ouellet

    2014-10-14T23:59:59.000Z

    CUORE is a 741 kg array of TeO2 bolometers that will search for the neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso in Italy, where it will begin taking data in 2015. The CUORE cryostat will cool several metric tonnes of material to below 1 K and the CUORE detector itself will operate at a typical temperature of 10 mK. At this temperature, the CUORE detector will be the coldest contiguous cubic meter in the known Universe.

  1. Meter-baseline tests of sterile neutrinos at Daya Bay

    E-Print Network [OSTI]

    Y. Gao; D. Marfatia

    2013-05-07T23:59:59.000Z

    We explore the sensitivity of an experiment at the Daya Bay site, with a point radioactive source and a few meter baseline, to neutrino oscillations involving one or more eV mass sterile neutrinos. We find that within a year, the entire 3+2 and 1+3+1 parameter space preferred by global fits can be excluded at the 3\\sigma level, and if an oscillation signal is found, the 3+1 and 3+2 scenarios can be distinguished from each other at more than the 3\\sigma level provided one of the sterile neutrinos is lighter than 0.5 eV.

  2. Portable Liquid Flow Metering for Energy Conservation Programs

    E-Print Network [OSTI]

    Miles, F. J.

    1982-01-01T23:59:59.000Z

    .c. jJ = 0.5 3. PERMANENT PRESSURE LOSS: PPL o = 72" w.c. See Table 3 4. HORSEPOWER REQUIRED TO MAKE UP PERMANENT PRESSURE LOSS: HP o = GPM x PPLo x SP. Gr. 38,000* (600) (72 )(1. 0) 38,000 HP o = 1.14 HP * Constant corrects for units...-7, 1982 TABLE 3 PERMANENT PRESSURE LOSS (PPL o ) FOR ORIFICE METERS 140 120 100 80 60 40 20 0 00?? '0 0.2 0.3 0.4 0.5 0.6 07 Beta ratio (d/Dl CONCLUSIONS Ultrasonic flowmetering offers an effec tive way to measure liquids in energy...

  3. The Coldest Cubic Meter in the Known Universe

    E-Print Network [OSTI]

    Ouellet, Jonathan

    2014-01-01T23:59:59.000Z

    CUORE is a 741 kg array of TeO2 bolometers that will search for the neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso in Italy, where it will begin taking data in 2015. The CUORE cryostat will cool several metric tonnes of material to below 1 K and the CUORE detector itself will operate at a typical temperature of 10 mK. At this temperature, the CUORE detector will be the coldest contiguous cubic meter in the known Universe.

  4. MSET modeling of Crystal River-3 venturi flow meters.

    SciTech Connect (OSTI)

    Bockhorst, F. K.; Gross, K. C.; Herzog, J. P.; Wegerich, S. W.

    1998-01-05T23:59:59.000Z

    The analysis of archived Crystal River-3 feedwater flow data reveals a slow and steady degradation of the flow meter measurements during the 1992/1993 operating cycle. MSET can reliably estimate the true flow rate and quantify the degree of departure between the indicated signal and the true flow rate with high accuracy. The MSET computed flow rate could, in principle, be used to provide an improved estimate of the reactor power and hence avoid the revenue loss associated with derating the reactor based on a faulty feedwater flow rate indication.

  5. EPAct 2005 Metering Guidance Overview | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: TopEnergy DOEDealingVehicle1:EnergyDecemberof Energy87:EPAct 2005 Metering

  6. O&M Metering Guidance | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAXBalanced ScorecardReactor Technology Subcommittee of NEACSummaryO&M Metering

  7. BPA Metering Services¬ź Editing and Estimating Procedures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD)ProductssondeadjustsondeadjustAboutScience Program CumulusA t iBudget2/4/139/4/2012 BnotMetering

  8. Smart Meter Investments Support Rural Economy in Arkansas

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment of Energy U.S. DepartmentCommitmentGovernmentSmart Cities - 1 SmartSmart Meter

  9. Cyprus Smart metering demo (Smart Grid Project) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating Solar Power Basics (The following text isRica NRELPower Comm JumpCyprus Smart metering

  10. CHARACTERIZATION OF THE ADVANCED RADIOGRAPHIC CAPABILITY FRONT END ON NIF

    SciTech Connect (OSTI)

    Haefner, C; Heebner, J; Dawson, J; Fochs, S; Shverdin, M; Crane, J K; Kanz, V K; Halpin, J; Phan, H; Sigurdsson, R; Brewer, W; Britten, J; Brunton, G; Clark, W; Messerly, M J; Nissen, J D; Nguyen, H; Shaw, B; Hackel, R; Hermann, M; Tietbohl, G; Siders, C W; Barty, C J

    2009-07-15T23:59:59.000Z

    We have characterized the Advanced Radiographic Capability injection laser system and demonstrated that it meets performance requirements for upcoming National Ignition Facility fusion experiments. Pulse compression was achieved with a scaled down replica of the meter-scale grating ARC compressor and sub-ps pulse duration was demonstrated at the Joule-level.

  11. Meter scale plasma source for plasma wakefield experiments

    SciTech Connect (OSTI)

    Vafaei-Najafabadi, N.; Shaw, J. L.; Marsh, K. A.; Joshi, C.; Hogan, M. J. [Department of Electrical Engineering, University of California Los Angeles, Los Angeles, CA 90095 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States)

    2012-12-21T23:59:59.000Z

    High accelerating gradients generated by a high density electron beam moving through plasma has been used to double the energy of the SLAC electron beam [1]. During that experiment, the electron current density was high enough to generate its own plasma without significant head erosion. In the newly commissioned FACET facility at SLAC, the peak current will be lower and without pre-ionization, head erosion will be a significant challenge for the planned experiments. In this work we report on our design of a meter scale plasma source for these experiments to effectively avoid the problem of head erosion. The plasma source is based on a homogeneous metal vapor gas column that is generated in a heat pipe oven [2]. A lithium oven over 30 cm long at densities over 10{sup 17} cm{sup -3} has been constructed and tested at UCLA. The plasma is then generated by coupling a 10 TW short pulse Ti:Sapphire laser into the gas column using an axicon lens setup. The Bessel profile of the axicon setup creates a region of high intensity that can stretch over the full length of the gas column with approximately constant diameter. In this region of high intensity, the alkali metal vapor is ionized through multi-photon ionization process. In this manner, a fully ionized meter scale plasma of uniform density can be formed. Methods for controlling the plasma diameter and length will also be discussed.

  12. The magnetic flywheel flow meter: Theoretical and experimental contributions

    SciTech Connect (OSTI)

    Buchenau, D., E-mail: d.buchenau@hzdr.de; Galindo, V.; Eckert, S. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, Bautzner LandstraŖe 400, 01328 Dresden (Germany)

    2014-06-02T23:59:59.000Z

    The development of contactless flow meters is an important issue for monitoring and controlling of processes in different application fields, like metallurgy, liquid metal casting, or cooling systems for nuclear reactors and transmutation machines. Shercliff described in his book ďThe Theory of Electromagnetic Flow Measurement, Cambridge University Press, 1962Ē a simple and robust device for contact-less measurements of liquid metal flow rates which is known as magnetic flywheel. The sensor consists of several permanent magnets attached on a rotatable soft iron plate. This arrangement will be placed closely to the liquid metal flow to be measured, so that the field of the permanent magnets penetrates into the fluid volume. The flywheel will be accelerated by a Lorentz force arising from the interaction between the magnetic field and the moving liquid. Steady rotation rates of the flywheel can be taken as a measure for the mean flow rate inside the fluid channel. The present paper provides a detailed theoretical description of the sensor in order to gain a better insight into the functional principle of the magnetic flywheel. Theoretical predictions are confirmed by corresponding laboratory experiments. For that purpose, a laboratory model of such a flow meter was built and tested on a GaInSn-loop under various test conditions.

  13. Quantum Metrology: Towards an alternative definition for the meter

    E-Print Network [OSTI]

    Ioannis P. Zois

    2012-03-05T23:59:59.000Z

    The motivation for this article came from an attempt to give an alternative definition for the meter, the SI unit for measuring length. As a starting point towards this goal, in this piece of work we present the underlying theory behind our approach which uses ideas from quantum field theory and noncommutative geometry, in particular the notion of an odd K-cycle which is based on the Dirac operator (and its inverse, the Dirac propagator). Using (the perhaps more familiar) physics terminology, the key point in our strategy is this: instead of measuring length directly in space-time we measure the "algebraic (spectral) length" in the space of the corresponding quantum states of some particle (fermion) acted upon by the Dirac propagator. This approach shares the spirit of the unanimus vote of the 24th General Conference of Standards and Measures (21st October 2011) in Serves, France for the redefinition of the fundamental units using Planck's constant.

  14. Photoelastic stress analysis on a Phoenix 7. 9-meter blade

    SciTech Connect (OSTI)

    Musial, W.D.; Jenks, M.D.; Osgood, R.M.; Johnson, J.A.

    1991-10-01T23:59:59.000Z

    Photoelastic tests were conducted on the Phoenix 7.9-meter blade to develop the basic methodology for locating critical strain areas on full-scale composite structures. Under relatively low elastic loading the strain fields over various regions on the blade planform were documented with 35mm photographs under different loading conditions at the Solar Energy Research Institute (SERI) Structural Test Facility (STF). Strain concentrations were easily located and quantified. Principal strain magnitudes and directions were determined at the highest strain areas using separator gages. Results were compared to measured operating loads. This experiment demonstrated the value of experimental stress analysis using the photoelastic technique for the evaluation of composite blade designs. 9 refs., 6 figs., 3 tabs.

  15. Mooring Motion Bias of Point-Doppler Current Meter Measurements Paul Freitag, Michael McPhaden, Chris Meinig, Patricia Plimpton

    E-Print Network [OSTI]

    Mooring Motion Bias of Point-Doppler Current Meter Measurements Paul Freitag, Michael Mc). Until 1998 the moorings were instrumented with mechanical current meters (MCMs, either Vector Averaging Current Meters (VACM) or Vector Measuring Current Meters (VMCM)). Comparison with nearby subsurface 150 k

  16. Meter Damage: Many customers have questions about who is responsible for repair to the electrical service at their homes. These pages may help to answer

    E-Print Network [OSTI]

    Rose, Annkatrin

    Meter Damage: Many customers have questions about who is responsible for repair. weather head stack meter base connectors house knob weather head connectors mast clamp stack meter base meter meter #12; Let's start with definitions: Meter base: This is the metal box mounted

  17. NIST Special Publication 1039r1 Liquid Flow Meter Calibrations with the

    E-Print Network [OSTI]

    NIST Special Publication 1039r1 Liquid Flow Meter Calibrations with the 0.1 L/s and the 2.5 L Publication 1039r1 Liquid Flow Meter Calibrations with the 0.1 L/s and the 2.5 L/s Piston Provers Jodie G. Technol. Spec. Publ. 1039r1, 55 pages (December 2013) CODEN: NSPUE2 #12;Liquid Flow Meter Calibrations

  18. A study of the coherent structures and installation effects in an orifice flow meter

    E-Print Network [OSTI]

    Pattabhi, Srikanth

    2012-06-07T23:59:59.000Z

    . Errors on the order of approximately 250 millions of dollar per year have been estimated for the natural gas industry. The urgent need to improve the accuracy has fueled basic research in the area of orifice flow meters. The objectives of this present... study were to analyze the coherent structures present in an orifice flow meter, and to examine the effect of a flow conditioner placed upstream of the orifice plate on the flow meter's accuracy, The coherent structures were measured by performing...

  19. Prison Industries Metering at the Texas Department of Criminal Justice: Two Years of Operational Experience

    E-Print Network [OSTI]

    Bryant, J.; McBride, J.; Merka, T.

    2003-01-01T23:59:59.000Z

    PRISON INDUSTRIES METERING AT THE TEXAS DEPARTMENT OF CRIMINAL JUSTICE: TWO YEARS OF OPERATIONAL EXPERIENCE John A. Bryant John R. McBride Tom Merka Assistant Professor Chief Executive Officer Director of Utilities & Energy Texas A... in the use of energy metering to promote cost-effective prison operation. REFERENCES 1. John A. Bryant, John McBride, Tom Merka, ?State-of-the-Art Energy Sub-metering Texas Department of Criminal Justice Industries,? Proceedings of the 1st...

  20. Uncertainty Analysis for a Virtual Flow Meter Using an Air-Handling Unit Chilled Water Valve

    SciTech Connect (OSTI)

    Song, Li; Wang, Gang; Brambley, Michael R.

    2013-04-28T23:59:59.000Z

    A virtual water flow meter is developed that uses the chilled water control valve on an air-handling unit as a measurement device. The flow rate of water through the valve is calculated using the differential pressure across the valve and its associated coil, the valve command, and an empirically determined valve characteristic curve. Thus, the probability of error in the measurements is significantly greater than for conventionally manufactured flow meters. In this paper, mathematical models are developed and used to conduct uncertainty analysis for the virtual flow meter, and the results from the virtual meter are compared to measurements made with an ultrasonic flow meter. Theoretical uncertainty analysis shows that the total uncertainty in flow rates from the virtual flow meter is 1.46% with 95% confidence; comparison of virtual flow meter results with measurements from an ultrasonic flow meter yielded anuncertainty of 1.46% with 99% confidence. The comparable results from the theoretical uncertainty analysis and empirical comparison with the ultrasonic flow meter corroborate each other, and tend to validate the approach to computationally estimating uncertainty for virtual sensors introduced in this study.

  1. Now that we have smart meters, what do we do with them?

    SciTech Connect (OSTI)

    NONE

    2010-01-15T23:59:59.000Z

    For years, electric utilities have been dreaming about the day when they would have smart meters on customers' premises. However, there have always been lingering doubts among some consumer advocates and critics of the smart metering schemes about their cost-effectiveness. An issue that is beginning to become noticed is that installing smart meters and introducing variable pricing will accomplish very little unless the price signals are communicated to consumers and -- more important -- to energy-using devices beyond the meter. Since consumers are unlikely to sit around watching variable prices and adjusting consumption or thermostat settings, ways must be found for the price signals to automatically and directly communicate with devices,.

  2. E-Print Network 3.0 - automatic meter reading Sample Search Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Collection: Computer Technologies and Information Sciences 23 Private Memoirs of a Smart Meter Andres Molina-Markham, Prashant Shenoy, Kevin Fu, Emmanuel Cecchet, and David...

  3. Experience in the Application of Single-Beam Ultrasonic Flow Meters for Turbines

    SciTech Connect (OSTI)

    Krasilnikov, A. M.; Dmitriev, S. G. [Joint-Stock Company 'Research Institute for Power Constructions' (Russian Federation); Karyakin, V. A. [Zagorsk Hydroelectric Pumped Storage Power Plant (Russian Federation)

    2002-03-15T23:59:59.000Z

    Experience in the use of ultrasonic flow meters at the Bratskaya and Vilyuiskaya HPP is described. The article is of interest to field engineers.

  4. REPORT ON RFI DE-FOA-000753: High-Accuracy Hydrogen Meters1

    E-Print Network [OSTI]

    , Savannah River National Lab; Nha Nguyen Senior Engineer Advisor, Office of International Policy not have to operate under the fueling environment. There are three basic meter types, gravimetric

  5. Genetic fuzzy logic approach to local ramp metering control using microscopic traffic simulation.

    E-Print Network [OSTI]

    Yu, Xue Feng

    2009-01-01T23:59:59.000Z

    ??Ramp metering, one of the most effective solutions for improving motorway traffic flows, is playing increasingly important role in traffic management systems. Because of itsÖ (more)

  6. An analysis of an application of radioactive ionization for gas flow metering

    E-Print Network [OSTI]

    Lam, Carroll Frank

    2012-06-07T23:59:59.000Z

    fulfillment of the requirements for ths legree of MASTER OF SC1ENCE May 1959 Major Subject: Electrical Engines x ing AN ANALYSIS OF AN APPLICATION OF RADIOACTIVE IONIZATION FOR l 1 '~, '1 1 ', '1 ' 1 1 "1 g 1 n \\ '& \\ GAS FLOW METERING A...'s Apparatus Z. An Ezperimental Flow Meter . 3. Mark I Meter and Test Equipment 4. Electrical Circuit 5. Current vs. Flow Rate Curve for Mark I Meter. . . . . . . . . . . . . 6. Current vs. Flow Rate for DifferentSource Spacings. . . . . . . . . . 7...

  7. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    E-Print Network [OSTI]

    Darghouth, Naim Richard

    2013-01-01T23:59:59.000Z

    The Private and Public Economies of Renewable Electricityprivate sector, began to push for deregulation in the electricityprivate customer value of behind-the-meter PV generation, as potential customers most often will consider the value of avoided electricity

  8. Flow meter evaluation for U.S. Navy Public Works Center, San Diego, California

    SciTech Connect (OSTI)

    Chvala, W.D. Jr.; McMordie, K.L.; Szydlowski, R.F.

    1995-06-01T23:59:59.000Z

    The U.S. Navy Public Works Center San Diego (PWCSD) was concerned about the accuracy of various flow meters on steam and compressed air lines serving Naval facilities in San Diego, California. The flow meters had experienced various inconsistencies that had not been resolved prior to July 1993. Pacific Northwest Laboratory, Richland, Washington, evaluated the operation of 10 out of 79 steam and compressed air flow meters at PWCSD. The evaluation was limited to analysis of historical information and review of existing operating procedures. On-site investigation of the flow meters was limited to external observations of the flow-sensing equipment and a check of the flow computer program. PNL did not remove installed sensing equipment (i.e., flow meters or temperature or pressure sensors) to evaluate existing condition or check calibration. Although many of the flow meter errors can be traced to improperly normalized readings and to meters improperly compensated for temperature and pressure, lack of regular maintenance, including proper calibration, was evidenced throughout this study. A strict calibration schedule should be established for all steam and air flow meters, including calibration of the temperature sensor, pressure sensor, and flow turbine. It is recommended that the most crucial flow meters (such as the 10 evaluated in this study) be calibrated yearly. The remaining 69 flow meters could be placed on a staggered, biyearly calibration schedule. Calibration should be done by qualified personnel only. Improper calibration is often worse than no calibration at all. An outside firm is recommended to be contracted with to perform all maintenance and calibration on flow meters at the Naval facilities. Use of an outside firm would better facilitate regular, reliable calibration while removing liability for damaged parts.

  9. Ash level meter for a fixed-bed coal gasifier

    DOE Patents [OSTI]

    Fasching, George E. (Morgantown, WV)

    1984-01-01T23:59:59.000Z

    An ash level meter for a fixed-bed coal gasifier is provided which utilizes the known ash level temperature profile to monitor the ash bed level. A bed stirrer which travels up and down through the extent of the bed ash level is modified by installing thermocouples to measure the bed temperature as the stirrer travels through the stirring cycle. The temperature measurement signals are transmitted to an electronic signal process system by an FM/FM telemetry system. The processing system uses the temperature signals together with an analog stirrer position signal, taken from a position transducer disposed to measure the stirrer position to compute the vertical location of the ash zone upper boundary. The circuit determines the fraction of each total stirrer cycle time the stirrer-derived bed temperature is below a selected set point, multiplies this fraction by the average stirrer signal level, multiplies this result by an appropriate constant and adds another constant such that a 1 to 5 volt signal from the processor corresponds to a 0 to 30 inch span of the ash upper boundary level. Three individual counters in the processor store clock counts that are representative of: (1) the time the stirrer temperature is below the set point (500.degree. F.), (2) the time duration of the corresponding stirrer travel cycle, and (3) the corresponding average stirrer vertical position. The inputs to all three counters are disconnected during any period that the stirrer is stopped, eliminating corruption of the measurement by stirrer stoppage.

  10. Quantum noise of non-ideal Sagnac speed meter interferometer with asymmetries

    E-Print Network [OSTI]

    S. L. Danilishin; C. Graef; S. S. Leavey; J. Hennig; E. A. Houston; D. Pascucci; S. Steinlechner; J. Wright; S. Hild

    2014-12-02T23:59:59.000Z

    The speed meter concept has been identified as a technique that can potentially provide laser-interferometric measurements at a sensitivity level which surpasses the Standard Quantum Limit (SQL) over a broad frequency range. As with other sub-SQL measurement techniques, losses play a central role in speed meter interferometers and they ultimately determine the quantum noise limited sensitivity that can be achieved. So far in the literature, the quantum noise limited sensitivity has only been derived for lossless or lossy cases using certain approximations (for instance that the arm cavity round trip loss is small compared to the arm cavity mirror transmission). In this article we present a generalised, analytical treatment of losses in speed meters that allows accurate calculation of the quantum noise limited sensitivity of Sagnac speed meters with arm cavities. In addition, our analysis allows us to take into account potential imperfections in the interferometer such as an asymmetric beam splitter or differences of the reflectivities of the two arm cavity input mirrors. Finally,we use the examples of the proof-of-concept Sagnac speed meter currently under construction in Glasgow and a potential implementation of a Sagnac speed meter in the Einstein Telescope (ET) to illustrate how our findings affect Sagnac speed meters with meter- and kilometre-long baselines.

  11. MODEL-DRIVEN ANALYTICS OF ENERGY METER DATA IN SMART HOMES

    E-Print Network [OSTI]

    Shenoy, Prashant

    MODEL-DRIVEN ANALYTICS OF ENERGY METER DATA IN SMART HOMES A Dissertation Presented by SEAN BARKER administrative tasks, to Tyler Trafford for frequent technical support, and to my past and present labmates Barker 2014 All Rights Reserved #12;MODEL-DRIVEN ANALYTICS OF ENERGY METER DATA IN SMART HOMES

  12. Silver Spring signs deal to make Sacramento meters smart June 23, 2009 | Camille Ricketts

    E-Print Network [OSTI]

    Lu, Chenyang

    GreenBeat Silver Spring signs deal to make Sacramento meters smart June 23, 2009 | Camille Ricketts Silver Spring Networks, one of the major players in the smart meter space, announced today that it signed a deal with the Sacramento Municipal Utility District to deploy a wireless network connecting smart

  13. Trinity College Green Week 2012 Energy Competition Win a Domestic Energy Meter

    E-Print Network [OSTI]

    O'Mahony, Donal E.

    Trinity College Green Week 2012 Energy Competition ­ Win a Domestic Energy Meter As part of College Green Week the "e3" programme and Director of Buildings Office is promoting an energy related would you like to win a domestic whole house energy meter as part of Trinity College Green Week 2012

  14. Response of a slotted plate flow meter to horizontal two phase flow

    E-Print Network [OSTI]

    Muralidharan, Vasanth

    2005-02-17T23:59:59.000Z

    meter is always better in performance and accuracy than the standard orifice plate flow meter. This study is primarily based on how a slotted plate responds to horizontal two-phase flow with air and water being used as the working fluids. The plates...

  15. Unaccounted-for gas project. Measurement Task Force (orifice meter studies). Volume 2B. Final report

    SciTech Connect (OSTI)

    Godkin, B.J.; Robertson, J.D.; Wlasenko, R.G.; Cowgill, R.M.; Grinstead, J.R.

    1990-06-01T23:59:59.000Z

    The study was aimed at determining unaccounted-for (UAF) gas volumes resulting from operating Pacific Gas and Electric Co.'s transmission and distribution systems during 1987. Activities and methods are described and results are presented for research conducted on orifice meter accuracy. The Measurement Task Force determined that orifice metering inaccuracies were the largest single contributor to 1987 UAF.

  16. Power Line Carrier (PLC) Signal Analysis of Smart Meters for Outlier Detection

    E-Print Network [OSTI]

    Akella, Srinivas

    Power Line Carrier (PLC) Signal Analysis of Smart Meters for Outlier Detection Rakesh Rao Dept-- A method for identifying outliers among a set of smart meters by using the power line carrier (PLC) signal strength is presented in this paper. The broad goal is to use the PLC signal as a predictor of transmission

  17. Amy Courtney: Freewheelin' Farm

    E-Print Network [OSTI]

    Rabkin, Sarah

    2010-01-01T23:59:59.000Z

    with some specific educational programs, with Food What?!program based at UCSCís Life Lab Garden Classroom. Other cultural and educational

  18. Scientist profile: Amy Bauer

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administrationcontroller systemsBi (2) Sr (2)Science HighlightAlanExchangeOffice of ScienceScientist

  19. ARM - AMIE Field Campaign

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLasDelivered¬ČPNGExperience4AJ01) (See95TI07)Operations2AP-XPSAPS50 -IssuegovFieldOverview

  20. Sandia National Laboratories: AMI

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 -the Mid-Infrared0 ResourceAwardsSafeguardsEngineers Wind EnergyAMF3 Sierra

  1. Speed Meter As a Quantum Nondemolition Measuring Device for Force

    E-Print Network [OSTI]

    F. Ya. Khalili; Yu. Levin

    1996-03-26T23:59:59.000Z

    Quantum noise is an important issue for advanced LIGO. Although it is in principle possible to beat the Standard Quantum Limit (SQL), no practical recipe has been found yet. This paper dicusses quantum noise in the context of speedmeter-a devise monitoring the speed of the testmass. The scheme proposed to overcome SQL in this case might be more practical than the methods based on monitoring position of the testmass.

  2. Advanced Combustion

    SciTech Connect (OSTI)

    Holcomb, Gordon R. [NETL

    2013-03-11T23:59:59.000Z

    The activity reported in this presentation is to provide the mechanical and physical property information needed to allow rational design, development and/or choice of alloys, manufacturing approaches, and environmental exposure and component life models to enable oxy-fuel combustion boilers to operate at Ultra-Supercritical (up to 650{degrees}C & between 22-30 MPa) and/or Advanced Ultra-Supercritical conditions (760{degrees}C & 35 MPa).

  3. Experimental test results presented for field-damaged orifice meter plates

    SciTech Connect (OSTI)

    Teyssandier, R.G.; Chisman, W.E.

    1984-04-30T23:59:59.000Z

    Tests demonstrate that, unlike other types of meters, there is minimal loss of accuracy with orifice meters even when operational excursions are such that severe damage occurs. Both flange taps and pipe taps effectively have the same general pattern in that the actual coefficient increases with increasing permanent deformation. Of the two types of orifice tap, these data indicate that flange-tapped orifices may be less susceptible to severe deformation. This is probably caused by changes in the local pressure gradients in the vicinity of the plate. Since pipe taps are at such a large distance from the plate, these changes are probably not noticeable due to the turbulent mixing that takes place. With orifice meters, visual inspection of the plates after severe operation is recommended, to tell the user if the plate is beyond specifications. With other types of meters (i.e., other than differential meters) recalibration is the only method of determining if the meter has been affected. Where damage is apparent, the plate (or the meter if it is not of the differential type) should be immediately replaced.

  4. Metered Evaporator for Tokamak Wall Conditioning --- Inventor(s): Charles

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: VegetationEquipment Surfaces andMapping theEnergy StorageAdvancedMetamaterials Research

  5. Aggregate Net Metering Opportunities for Local Governments | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top Five EERE Blog Posts1-034 Advance| Department ofthe StateAgenda_2015

  6. Electricit de France's study of the acoustic scintillation flow meter results in expanding its range and sensitivity

    E-Print Network [OSTI]

    Paris-Sud XI, Universitť de

    for the next generation of acoustic scintillation flow meters. 1. Background For EDF's hydraulic power division, turbine flow metering represents a high stake issue as it involves a significant amount of knowhow, work

  7. Instrument Qualification of Custom Fabricated Water Activity Meter for Hot Cell Use

    SciTech Connect (OSTI)

    McCoskey, Jacob K.

    2014-01-22T23:59:59.000Z

    This report describes a custom fabricated water activity meter and the results of the qualification of this meter as described in the laboratory test plan LAB-PLN-11-00012, Testing and Validation of an Enhanced Acquisition and Control System. It was calibrated against several NaOH solutions of varying concentrations to quantify the accuracy and precision of the instrument at 20 įC and 60 įC. Also, a schematic and parts list of the equipment used to make the water activity meter will be presented in this report.

  8. DREAM: DiffeRentially privatE smArt Metering

    E-Print Network [OSTI]

    Acs, Gergely

    2012-01-01T23:59:59.000Z

    This paper presents a new privacy-preserving smart metering system. Our scheme is private under the differential privacy model and therefore provides strong and provable guarantees. With our scheme, an (electricity) supplier can periodically collect data from smart meters and derive aggregated statistics while learning only limited information about the activities of individual households. For example, a supplier cannot tell from a user's trace when he watched TV or turned on heating. Our scheme is simple, efficient and practical. Processing cost is very limited: smart meters only have to add noise to their data and encrypt the results with an efficient stream cipher.

  9. Advanced Combustion

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD)ProductssondeadjustsondeadjustAbout the Building TechnologiesS1!4T opAddress:AdolphusAdvanced Energy

  10. Advanced Vehicle Testing & Evaluation

    Broader source: Energy.gov (indexed) [DOE]

    Provide benchmark data for advanced technology vehicles Develop lifecycle cost data for production vehicles utilizing advanced power trains Provide fleet...

  11. A model of the VU (volume-unit) meter, with speech applications Bryce E. Lobdell and Jont B. Allen

    E-Print Network [OSTI]

    Allen, Jont

    A model of the VU (volume-unit) meter, with speech applications Bryce E. Lobdell and Jont B. Allen October 2006; accepted 12 October 2006 The Volume-Unit VU meter, used in speech research prior. There are no known software implementations of this meter, which meet the 1954 ASA standard and provide

  12. Smart Meter Aggregation via Secret-Sharing George Danezis, Cdric Fournet, Markulf Kohlweiss, Santiago Zanella-Bguelin

    E-Print Network [OSTI]

    Danezis, George

    Smart Meter Aggregation via Secret-Sharing George Danezis, Cédric Fournet, Markulf Kohlweiss,fournet,markulf,santiago}@microsoft.com ABSTRACT We design and prototype protocols for processing smart- meter readings while preserving user by adapting to our setting efficient secret-sharing-based secure multi-party computation tech- niques. Meter

  13. Monjolo: An Energy-Harvesting Energy Meter Architecture Samuel DeBruin, Bradford Campbell, and Prabal Dutta

    E-Print Network [OSTI]

    Dutta, Prabal

    Monjolo: An Energy-Harvesting Energy Meter Architecture Samuel DeBruin, Bradford Campbell 48109 {sdebruin,bradjc,prabal}@eecs.umich.edu ABSTRACT Conventional AC power meters perform at least two distinct func- tions: power conversion, to supply the meter itself, and energy me- tering, to measure

  14. Private Memoirs of a Smart Meter Andres Molina-Markham, Prashant Shenoy, Kevin Fu, Emmanuel Cecchet, and David Irwin

    E-Print Network [OSTI]

    Shenoy, Prashant

    Private Memoirs of a Smart Meter Andr¬īes Molina-Markham, Prashant Shenoy, Kevin Fu, Emmanuel,shenoy,kevinfu,cecchet,irwin}@cs.umass.edu Abstract Household smart meters that measure power consumption in real-time at fine granularities are the foundation of a future smart electricity grid. However, the widespread deployment of smart meters has serious

  15. Traffic Equilibration: The Case of the Twin Cities Ramp Meter Shut Off David Levinson1and Atif Sheikh2

    E-Print Network [OSTI]

    Levinson, David M.

    Traffic Equilibration: The Case of the Twin Cities Ramp Meter Shut Off David Levinson1and Atif Sheikh2 Abstract In Fall 2000, more than 430 ramp meters in the Twin Cities metropolitan area were shut down in order to evaluate the effectiveness of the metering system. This shutdown disturbed normal

  16. Advanced LIGO

    E-Print Network [OSTI]

    The LIGO Scientific Collaboration

    2014-11-17T23:59:59.000Z

    The Advanced LIGO gravitational wave detectors are second generation instruments designed and built for the two LIGO observatories in Hanford, WA and Livingston, LA. The two instruments are identical in design, and are specialized versions of a Michelson interferometer with 4 km long arms. As in initial LIGO, Fabry-Perot cavities are used in the arms to increase the interaction time with a gravitational wave, and power recycling is used to increase the effective laser power. Signal recycling has been added in Advanced LIGO to improve the frequency response. In the most sensitive frequency region around 100 Hz, the design strain sensitivity is a factor of 10 better than initial LIGO. In addition, the low frequency end of the sensitivity band is moved from 40 Hz down to 10 Hz. All interferometer components have been replaced with improved technologies to achieve this sensitivity gain. Much better seismic isolation and test mass suspensions are responsible for the gains at lower frequencies. Higher laser power, larger test masses and improved mirror coatings lead to the improved sensitivity at mid- and high- frequencies. Data collecting runs with these new instruments are planned to begin in mid-2015.

  17. Have You Used an Electric Meter to Measure Your Energy Use? ...

    Broader source: Energy.gov (indexed) [DOE]

    of fun to put actual numbers to the various items in your home. Have you used an electric meter to measure your energy use? Tell us about your experience. Each Thursday, you have...

  18. NREL: Wind Research - New 100-Meter Map Keeps Pace with Growing...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    New 100-Meter Map Keeps Pace with Growing Wind Technology An illustrated map of the United States shows the average wind speeds of land-based and offshore wind speed The new 100-m...

  19. Evaluation of a Close Coupled Slotted Orifice, Electrical Impedance, and Swirl Flow Meters for Multiphase Flow

    E-Print Network [OSTI]

    Cevik, Muhammet

    2013-09-11T23:59:59.000Z

    homogenized flow for several pipe diameters downstream of the plate. This characteristic provides a homogeneous mixture at the inlet of the swirl meter, and impedance probe for gas volume fraction measurement (GVF). In order to evaluate the performance...

  20. Use of Rapid Temperature Measurements at a 2-Meter Depth to Augment...

    Open Energy Info (EERE)

    Measurements at a 2-Meter Depth to Augment Deeper Temperature Gradient Drilling Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Use of Rapid...

  1. High Resolution Study of Micro-Meter Particle Detachment and Resuspension on Different Surfaces

    E-Print Network [OSTI]

    Kassab, Asmaa 1983-

    2012-08-16T23:59:59.000Z

    In an effort to understand the resuspension phenomena, interactions of spherical micro-meter particles (glass beads (GB) and Stainless steel (SS)) were investigated experimentally on different surfaces (glass, ceramic, hardwood, metal and chemical...

  2. Deployment of Behind-The-Meter Energy Storage for Demand Charge...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Deployment of Behind-The- Meter Energy Storage for Demand Charge Reduction J. Neubauer and M. Simpson Technical Report NRELTP-5400-63162 January 2015 NREL is a national laboratory...

  3. Microsoft Word - Ross-Lexington No1 Meter project-CX .doc

    Broader source: Energy.gov (indexed) [DOE]

    Action: Ross-Lexington No. 1 Meter Project Budget Information: Work Order 00220904 Task 1 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B3.1 Onsite and...

  4. Assessment of TexSIM capabilities for analyzing freeway ramp metering

    E-Print Network [OSTI]

    Neerudu, Venugopal R

    2012-06-07T23:59:59.000Z

    capabilities. The purposes of this study were to calibrate the TEXSIM model for various traffic facilities and to assess its capabilities of freeway simulation with various ramp metering strategies. Due to lack of suitable field data, the TEXSIM model...

  5. Metering and Monitoring Approaches for Verifying Energy Savings from Energy Conservation Retrofits: Experiences from the Field

    E-Print Network [OSTI]

    McBride, J. R.; Bohmer, C. J.; Lippman, R. H.

    METERING AND MONITORING APPROACHES FOR VERIFYING ENERGY SAVINGS FROM ENERGY CONSERVATION RETROFITS: EXPERIENCES FROM THE FIELD John R. McBride Charles J. Bohmer Roger H. Lippman Senior Scientist Senior Instrumentation Senior Instrumentation... drying process that operates at a constant energy level on a constant schedule are examples of this class of load. Engineering calculations without in-field metering and monitoring may be sufficient for this project class. Next in complexity...

  6. The effects between two slotted plate flow meter under single, two, three components flow condition

    E-Print Network [OSTI]

    Park, Sang Hyan

    2005-02-17T23:59:59.000Z

    THE INTERACTION BETWEEN A TWO SLOTTED PLATE FLOW METER UNDER ONE, TWO, OR THREE COMPONENT FLOW CONDITIONS A Thesis by SANG HYUN PARK Submitted to the Office of Graduate Studies of Texas A&M University in partial... fulfillment of the requirements for the degree of MASTER OF SCIENCE December 2004 Major Subject: Mechanical Engineering THE INTERACTION BETWEEN A TWO SLOTTED PLATE FLOW METER UNDER ONE, TWO, OR THREE COMPONENT FLOW...

  7. Sub-metering to Electricity Use in Large-scale Commercial Buildings

    E-Print Network [OSTI]

    Yuan, W.

    2006-01-01T23:59:59.000Z

    ;?#0;? Practice??Project example #0;?#0;? Use of data??Analysis Software Sub-metering and statistics to electricity use in commercial buildings 8 Method of sub-metering Whole electric power consumption of a building Hvac system Heating Circulating pump Oter... systems and equipments Equipments on Socket Special function room Electrically driven heating equipment Chiller Fan of cooling tower Chilled pump cooling pump Air hand unit Fresh air hand unit Fan coil unit Air conditioner Heating water system drinking...

  8. Evaluation of a slotted orifice plate flow meter using horizontal two phase flow

    E-Print Network [OSTI]

    Flores, Anita Elena

    2000-01-01T23:59:59.000Z

    EVALUATION OF A SLOTTED ORIFICE PLATE FLOW METER USING HORIZONTAL TWO PHASE FLOW A Thesis by ANITA ELENA FLORES Submitted to the Office of Graduate Studies of Texas ARM University in partial fulfillment of the requirements for the degree... of MASTER OF SCIENCE December 2000 Major Subject: Mechanical Engineering EVALUATION OF A SLOTTED ORIFICE PLATE FLOW METER USING HORIZONTAL TWO PHASE FLOW A Thesis by ANITA ELENA FLORES Submitted to Texas A&M University in partial fulfillment...

  9. A field example of a gas orifice meter with debris-ridden liquid in mist flow

    SciTech Connect (OSTI)

    Chisholm, J.L.; Mooney, C.V. [Texas A and M Univ., Kingsville, TX (United States); Datta-Barua, L.; Feldmann, R.J.

    1995-12-31T23:59:59.000Z

    A field example of debris-ridden liquids in an orifice meter is presented in this paper. Flow conditions in gas pipelines containing hydrocarbon liquids and particulate matter are discussed. Known effects on measurement of the presence of these materials in orifice meters is presented. By definition, gas measurement is accurate if performed on a clean and dry flow stream. This paper demonstrates the importance of removing as much liquid and debris as possible prior to measurement.

  10. Why Insertion Turbine Meters are Replacing Orifice Plates for Steam Flow Measurement

    E-Print Network [OSTI]

    Rusnak, J. J.

    1983-01-01T23:59:59.000Z

    WHY INSERTION TURBINE MBTBRS A E REPLACING ORIFICE PLATES FOR STEAM FLOW MEASURE ENT J. J. Rusnak Engineering Measurements Company Longmont, Colorado ABSTRACT Flow measurement is a complex and application related discipline. It borders... to be instrumented quickly, economically and without dis rupting production; and further, these meters had to be accurate in order to be useful in making energy saving decisions. Thus, the entry of the insertion turbine meter for steam in 1975. Since then it has...

  11. Constructing a Merged Cloud-Precipitation Radar Dataset for Tropical Convective Clouds during the DYNAMO/AMIE Experiment at Addu Atoll

    SciTech Connect (OSTI)

    Feng, Zhe; McFarlane, Sally A.; Schumacher, Courtney; Ellis, Scott; Comstock, Jennifer M.; Bharadwaj, Nitin

    2014-05-16T23:59:59.000Z

    To improve understanding of the convective processes key to the Madden-Julian-Oscillation (MJO) initiation, the Dynamics of the MJO (DYNAMO) and Atmospheric Radiation Measurement MJO Investigation Experiment (AMIE) collected four months of observations from three radars, the S-band Polarization Radar (S-Pol), the C-band Shared Mobile Atmospheric Research & Teaching Radar (SMART-R), and Ka-band Zenith Radar (KAZR) on Addu Atoll in the tropical Indian Ocean. This study compares the measurements from the S-Pol and SMART-R to those from the more sensitive KAZR in order to characterize the hydrometeor detection capabilities of the two scanning precipitation radars. Frequency comparisons for precipitating convective clouds and non-precipitating high clouds agree much better than non-precipitating low clouds for both scanning radars due to issues in ground clutter. On average, SMART-R underestimates convective and high cloud tops by 0.3 to 1.1 km, while S-Pol underestimates cloud tops by less than 0.4 km for these cloud types. S-Pol shows excellent dynamic range in detecting various types of clouds and therefore its data are well suited for characterizing the evolution of the 3D cloud structures, complementing the profiling KAZR measurements. For detecting non-precipitating low clouds and thin cirrus clouds, KAZR remains the most reliable instrument. However, KAZR is attenuated in heavy precipitation and underestimates cloud top height due to rainfall attenuation 4.3% of the time during DYNAMO/AMIE. An empirical method to correct the KAZR cloud top heights is described, and a merged radar dataset is produced to provide improved cloud boundary estimates, microphysics and radiative heating retrievals.

  12. Cyber Security & Smart Grid

    E-Print Network [OSTI]

    Shapiro, J.

    2011-01-01T23:59:59.000Z

    Cyber Security & Smart Grid Jonathan Shapiro Texas Institute The Clean Air Through Energy Efficiency (CATEE) Conference Cyber Security & Smart Grid ESL-KT-11-11-23 CATEE 2011, Dallas, Texas, Nov. 7 ? 9, 2011 Cyber Security and The Smart... and communication protocols. ESL-KT-11-11-23 CATEE 2011, Dallas, Texas, Nov. 7 ? 9, 2011 Smart Grid Systems ?Current Cyber Security Issues ? Advanced Metering Infrastructure (AMI) Security ? The wireless devices are used in the smart meters located...

  13. Using Wireless Power Meters to Measure Energy Use of Miscellaneous and Electronic Devices in Buildings

    SciTech Connect (OSTI)

    UC Berkeley, Berkeley, CA USA; Brown, Richard; Lanzisera, Steven; Cheung, Hoi Ying (Iris); Lai, Judy; Jiang, Xiaofan; Dawson-Haggerty, Stephen; Taneja, Jay; Ortiz, Jorge; Culler, David

    2011-05-24T23:59:59.000Z

    Miscellaneous and electronic devices consume about one-third of the primary energy used in U.S. buildings, and their energy use is increasing faster than other end-uses. Despite the success of policies, such as Energy Star, that promote more efficient miscellaneous and electronic products, much remains to be done to address the energy use of these devices if we are to achieve our energy and carbon reduction goals. Developing efficiency strategies for these products depends on better data about their actual usage, but very few studies have collected field data on the long-term energy used by a large sample of devices due to the difficulty and expense of collecting device-level energy data. This paper describes the development of an improved method for collecting device-level energy and power data using small, relatively inexpensive wireless power meters. These meters form a mesh network based on Internet standard protocols and can form networks of hundreds of metering points in a single building. Because the meters are relatively inexpensive and do not require manual data downloading, they can be left in the field for months or years to collect long time-series energy use data. In addition to the metering technology, we also describe a field protocol used to collect comprehensive, robust data on the miscellaneous and electronic devices in a building. The paper presents sample results from several case study buildings, in which all the plug-in devices for several homes were metered, and a representative sample of several hundred plug-in devices in a commercial office building were metered for several months.

  14. Development of the prototype Munitions Case Moisture Meter, Model ORNL-1

    SciTech Connect (OSTI)

    Agouridis, D.C.; Gayle, T.M.; Griest, W.H.

    1993-02-24T23:59:59.000Z

    There is a great need for a rapid and simple means of determining the moisture content in combustible cartridge case (ccc) munitions. Previous studies have demonstrated that accumulation of moisture in ccc rounds, such as the M829, leads to softening of the case wall and weakening of the adhesive joint. Moisture in the ccc can lead to incomplete combustion of the case upon firing the round. Currently, there are no facile methods for measuring the moisture content. A prototype portable meter for non-destructive and rapid estimation of moisture in ccc has been developed. The Munitions Case Moisture Meter Model ORNL-1 demonstrates the feasibility of developing an instrument based on the moisture dependence of dielectric properties, to measure moisture in ccc munitions in storage and in the field. These instruments are simple, inexpensive, lightweight, portable, low-power battery operated, and intrinsically safe. They provide nondestructive, noninvasive, and rapid measurements. Calibration data for the prototype are not available at this time. Therefore, calibration of the meter and the development of a scale reading directly moisture content in munitions rounds could not be completed. These data will be supplied by the US Army from its tests of the meter with actual munitions. However, experimental results on empty cccs in laboratory conditions demonstrate satisfactory performance of the instrument. Additional work is needed to bring the prototype to its optimum usefulness and accuracy for field measurements. This includes: Calibration of the meter scale with full-up munitions; Data and evaluation procedures to adjust the performance of the meter for different environmental conditions such as temperature and humidity; and Studies of the dielectric properties of moist ccc materials, as a function of frequency and temperature, are needed for adjustment of the meter for optimal performance.

  15. Development of the prototype Munitions Case Moisture Meter, Model ORNL-1. Final report

    SciTech Connect (OSTI)

    Agouridis, D.C.; Gayle, T.M.; Griest, W.H.

    1993-02-24T23:59:59.000Z

    There is a great need for a rapid and simple means of determining the moisture content in combustible cartridge case (ccc) munitions. Previous studies have demonstrated that accumulation of moisture in ccc rounds, such as the M829, leads to softening of the case wall and weakening of the adhesive joint. Moisture in the ccc can lead to incomplete combustion of the case upon firing the round. Currently, there are no facile methods for measuring the moisture content. A prototype portable meter for non-destructive and rapid estimation of moisture in ccc has been developed. The Munitions Case Moisture Meter Model ORNL-1 demonstrates the feasibility of developing an instrument based on the moisture dependence of dielectric properties, to measure moisture in ccc munitions in storage and in the field. These instruments are simple, inexpensive, lightweight, portable, low-power battery operated, and intrinsically safe. They provide nondestructive, noninvasive, and rapid measurements. Calibration data for the prototype are not available at this time. Therefore, calibration of the meter and the development of a scale reading directly moisture content in munitions rounds could not be completed. These data will be supplied by the US Army from its tests of the meter with actual munitions. However, experimental results on empty cccs in laboratory conditions demonstrate satisfactory performance of the instrument. Additional work is needed to bring the prototype to its optimum usefulness and accuracy for field measurements. This includes: Calibration of the meter scale with full-up munitions; Data and evaluation procedures to adjust the performance of the meter for different environmental conditions such as temperature and humidity; and Studies of the dielectric properties of moist ccc materials, as a function of frequency and temperature, are needed for adjustment of the meter for optimal performance.

  16. Demand Reductions from the Application of Advanced Metering Infrastructure, Pricing Programs, and Customer-Based Systems - Intial Results

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergy CooperationRequirements Matrix U.S. Department of Energy | December 2012 Table of Contents

  17. Analysis and methodology for measuring oxygen concentration in liquid sodium with a plugging meter

    SciTech Connect (OSTI)

    Nollet, B. K.; Hvasta, M.; Anderson, M. [Univ. of Wisconsin-Madison, 1500 Engineering Dr., Madison, WI 53706 (United States)

    2012-07-01T23:59:59.000Z

    Oxygen concentration in liquid sodium is a critical measurement in assessing the potential for corrosion damage in sodium-cooled fast reactors (SFRs). There has been little recent work on sodium reactors and oxygen detection. Thus, the technical expertise dealing with oxygen measurements within sodium is no longer readily available in the U.S. Two methods of oxygen detection that have been investigated are the plugging meter and the galvanic cell. One of the overall goals of the Univ. of Wisconsin's sodium research program is to develop an affordable, reliable galvanic cell oxygen sensor. Accordingly, attention must first be dedicated to a well-known standard known as a plugging meter. Therefore, a sodium loop has been constructed on campus in effort to develop the plugging meter technique and gain experience working with liquid metal. The loop contains both a galvanic cell test section and a plugging meter test section. Consistent plugging results have been achieved below 20 [wppm], and a detailed process for achieving effective plugging has been developed. This paper will focus both on an accurate methodology to obtain oxygen concentrations from a plugging meter, and on how to easily control the oxygen concentration of sodium in a test loop. Details of the design, materials, manufacturing, and operation will be presented. Data interpretation will also be discussed, since a modern discussion of plugging data interpretation does not currently exist. (authors)

  18. 3rd International symposium on fluid flow measurement effects of acoustic noise on orifice meters

    SciTech Connect (OSTI)

    Norman, R.; Graham, P.; Drew, W.A. [Engineering Research Station, Newcastle Upon Tyne (United Kingdom)

    1995-12-31T23:59:59.000Z

    It is known that in-pipe acoustic noise can cause errors in orifice plate metering. The international metering community voted this topic as the highest priority for further research during a {open_quotes}working{close_quotes} held at N.T.I.S. in 1983. Most published work to date has been concerned with periodic, low frequency noise or pulsations, as encountered on reciprocating compressor installations where errors or their side effects may be readily noticed. Many orifice metering locations are, however, subject to high frequency noise emanating from control valves and centrifugal compressors. High frequency in-pipe noise is seldom suspected as a source of metering error and consequently it is a neglected topic. Square root error, which stems form the non-linear flow-differential pressure relationship of an orifice plate, has been well researched for low frequencies but the work has not been extended to high frequencies. To investigate this topic, high pressure studies at the British Gas Bishop Auckland Test Facility were carried out with a noise source (a pressure drop across a ball valve) and a 600 mm 0.4 {beta} orifice meter. These studies identified the effect of high frequency acoustic noise on orifice plate accuracy.

  19. Optical position meters analyzed in the non-inertial reference frames

    E-Print Network [OSTI]

    Sergey P. Tarabrin; Alexander A. Seleznyov

    2008-09-03T23:59:59.000Z

    In the framework of General Relativity we develop a method for analysis of the operation of the optical position meters in their photodetectors proper reference frames. These frames are non-inertial in general due to the action of external fluctuative forces on meters test masses, including detectors. For comparison we also perform the calculations in the laboratory (globally inertial) reference frame and demonstrate that for certain optical schemes laboratory-based analysis results in unmeasurable quantities, in contrast to the detector-based analysis. We also calculate the response of the simplest optical meters to weak plane gravitational waves and fluctuative motions of their test masses. It is demonstrated that for the round-trip meter analysis in both the transverse-traceless (TT) and local Lorentz (LL) gauges produces equal results, while for the forward-trip meter corresponding results differ in accordance with different physical assumptions (e.g. procedure of clocks synchronization) implicitly underlying the construction of the TT and LL gauges.

  20. Results mixed from pulsating flow tests of orifice-plate meters

    SciTech Connect (OSTI)

    Arasi, J.A. (Phillips Petroleum Co., Tananger (Norway))

    1992-10-05T23:59:59.000Z

    This paper reports that laboratory tests on several commercially available orifice-plate meters for use in pulsating flow indicate that none yields acceptable accuracy. These tests suggested, however, that if the objective of monitoring pulsating flow is to indicate or quantify pulsation magnitudes for comparisons, then at least two instruments are acceptable. Use of such meters, particularly in low flow rate gathering systems, can be a viable alternative to attempting to reduce the intensity (amplitude and frequency) of pulsation by expensive installation and maintenance of chokes and bottles. Phillips Petroleum Co. set out to find a meter that would be sensitive enough to measure pulsating hydrocarbon flows with acceptable accuracy using the orifice plate. Several orifice measurement systems were simultaneously investigated at the Southwest Research Institute, San Antonio (SwRI).

  1. Thirty-meter digital elevation models (DEMs) produced by the U.S. Geological Survey (USGS) are widely available and com-

    E-Print Network [OSTI]

    Abstract Thirty-meter digital elevation models (DEMs) produced by the U.S. Geological Survey (USGS, and slope classes gen- erated from sample 10-meter drainage-enforced (DE) DEMs and 30-meter DEMs. We found increasing resolution from 30 meters to 10 me- ters, particularly in flatter terrain; (2) streams and HU

  2. Meter Eligibility Listing Procedure Updated 6/2/14 The California Solar Initiative (CSI) is for all market segments with the exception of New

    E-Print Network [OSTI]

    Meter Eligibility Listing Procedure Updated 6/2/14 The California Solar on the accuracy of the meter there are two different routes to eligibility listing: Nonrevenue grade meters: 1. The meter must be selfcertified by the manufacturer to an accuracy of +/ 5%. 2. Fill out

  3. Monitoring the Thermal Power of Nuclear Reactors with a Prototype Cubic Meter Antineutrino Detector

    E-Print Network [OSTI]

    A. Bernstein; N. S. Bowden; A. Misner; T. Palmer

    2008-04-30T23:59:59.000Z

    In this paper, we estimate how quickly and how precisely a reactor's operational status and thermal power can be monitored over hour to month time scales, using the antineutrino rate as measured by a cubic meter scale detector. Our results are obtained from a detector we have deployed and operated at 25 meter standoff from a reactor core. This prototype can detect a prompt reactor shutdown within five hours, and monitor relative thermal power to three percent within seven days. Monitoring of short-term power changes in this way may be useful in the context of International Atomic Energy Agency's (IAEA) Reactor Safeguards Regime, or other cooperative monitoring regimes.

  4. Constancy of built-in luminance meter measurements in diagnostic displays

    SciTech Connect (OSTI)

    Silosky, M., E-mail: michael.silosky@ucdenver.edu; Marsh, R. M. [Department of Radiology, University of Colorado, School of Medicine Aurora, Colorado 80045 (United States)] [Department of Radiology, University of Colorado, School of Medicine Aurora, Colorado 80045 (United States)

    2013-12-15T23:59:59.000Z

    Purpose: Liquid crystal displays used to interpret medical images are often equipped with built-in luminance meters to evaluate luminance response and Grayscale Standard Display Function conformance. This work evaluates agreement between luminance reported by the built-in meters and external measurements. Methods: The white level luminance was measured using a built-in meter and an external meter for 93 primary review workstations (Models MFGD 3420 and MDCG 3120-CB) with between 117 and 49?336 backlight hours (BLH). Measured luminance values were compared viat-test for displays with less than 25?000 BLH and those with more than 25?000 BLH. Bias between meters was also evaluated. Changes in luminance uniformity with increasing backlight hours were explored by determining the maximum luminance deviation (MLD) for subsets of these displays with less than 800 BLH and greater than 35?000 BLH. Results: The mean difference between built-in and external luminance measurements was 5.84% and 38.92% for displays with less than 25?000 and greater than 25?000 BLH, respectively, with a statistically significant difference in the means (p < 0.001). For displays with low BLH, a statistically significant bias was observed (p < 0.001) between built-in and external measurements. A high degree of correlation was observed between measurements made with two separate external meters (r = 0.999). The mean MLD was 9.5% and 11.2% for MDCG 3120-CB displays with less than 800 and greater than 35?000 BLH, respectively. The difference in the mean values was not statistically significant (p < 0.001). Conclusions: Disagreement between the white level luminance measured using the built-in and external meter increased with BLH. Consequently, reliance on values reported by the built-in luminance meter may result in a reduction in image contrast with time. Recommendations have been proposed regarding luminance response testing and corrective action for failing displays.

  5. Currents and waters of the upper 1200 meters of the southwestern Gulf of Mexico

    E-Print Network [OSTI]

    Vasquez de la Cerda, Alberto Mariano

    1975-01-01T23:59:59.000Z

    CURRENTS AND WATERS OF THE UPPER 1200 METERS OF THE SOUTHWESTERN GULF OF MEXICO A Thesis by ALBERTO MARIANO VAZQUEZ DE LA CERDA Submitted to the Graduate College of Texas A&M University in partial fulfillment of the requirement for the degree... of MASTER OF SCIENCE August 1975 Major Subject: Oceanography CURRENTS AND WATERS OF THE UPPER 1200 METERS OF THE SOUTHWESTERN GULF OP MEXICO A Thesis by ALBERTO MARIANO VAZ0UEZ DE LA CERDA Approved as to style and content by: , , l (Chairman...

  6. Thermal Energy Measurement with Tangential Paddlewheel Flow Meters: Summary of Experimental Results and in-situ Diagnostics

    E-Print Network [OSTI]

    Haberl, J. S.; Watt, J. B.

    1994-01-01T23:59:59.000Z

    paddlewheel flow meters, and several new methods for in-situ diagnostic measures for ascertaining whether or not a flow meter is experiencing fluctuating flow conditions or if a flow meter is suffering a degraded signal due to shaft wear. INTRODUCTION Flow... section where it passes across the candidate sensor that is placed in the inter-changeable test section, through the orifice plate and finally into the is combined with Btu meter the threshold can be much higher than the published threshold of the flow...

  7. Bio-Rad Laboratories q u a l i t y c o n t r o l Meter TraxTM

    E-Print Network [OSTI]

    Rodriguez, Carlos

    Bio-Rad Laboratories q u a l i t y c o n t r o l Meter TraxTM Control #12;q u a l i t y c o n t r o l Meter TraxTM Control Quality Control Meter TraxTM is an ideal quality control for point-of-care meters. It is available in easy-to-use dropper bottles and has assigned values for many meters

  8. Evaluation of convection-permitting model simulations of cloud populations associated with the Madden-Julian Oscillation using data collected during the AMIE/DYNAMO field campaign

    SciTech Connect (OSTI)

    Hagos, Samson M.; Feng, Zhe; Burleyson, Casey D.; Lim, Kyo-Sun; Long, Charles N.; Wu, Di; Thompson, Gregory

    2014-11-12T23:59:59.000Z

    Regional cloud permitting model simulations of cloud populations observed during the 2011 ARM Madden Julian Oscillation Investigation Experiment/ Dynamics of Madden-Julian Experiment (AMIE/DYNAMO) field campaign are evaluated against radar and ship-based measurements. Sensitivity of model simulated surface rain rate statistics to parameters and parameterization of hydrometeor sizes in five commonly used WRF microphysics schemes are examined. It is shown that at 2 km grid spacing, the model generally overestimates rain rate from large and deep convective cores. Sensitivity runs involving variation of parameters that affect rain drop or ice particle size distribution (more aggressive break-up process etc) generally reduce the bias in rain-rate and boundary layer temperature statistics as the smaller particles become more vulnerable to evaporation. Furthermore significant improvement in the convective rain-rate statistics is observed when the horizontal grid-spacing is reduced to 1 km and 0.5 km, while it is worsened when run at 4 km grid spacing as increased turbulence enhances evaporation. The results suggest modulation of evaporation processes, through parameterization of turbulent mixing and break-up of hydrometeors may provide a potential avenue for correcting cloud statistics and associated boundary layer temperature biases in regional and global cloud permitting model simulations.

  9. Market Technical Analysis for the iMarket Meter Data Management System

    E-Print Network [OSTI]

    Lowe, Patrick

    2005-12-16T23:59:59.000Z

    Based on recent success with Swiftís iMarket Meter Data Management System (MDMS) product in the Southwest Power Pool (SPP), additional wholesale energy markets need to be analyzed to determine the feasibility of marketing and selling the MDMS...

  10. Radiation dose-rate meter using an energy-sensitive counter

    DOE Patents [OSTI]

    Kopp, Manfred K. (Oak Ridge, TN)

    1988-01-01T23:59:59.000Z

    A radiation dose-rate meter is provided which uses an energy-sensitive detector and combines charge quantization and pulse-rate measurement to monitor radiation dose rates. The charge from each detected photon is quantized by level-sensitive comparators so that the resulting total output pulse rate is proportional to the dose-rate.

  11. An investigation of effects of flow conditioning on straight tube Coriolis meter

    E-Print Network [OSTI]

    Shukla, Shashank

    2009-05-15T23:59:59.000Z

    Coriolis meter, despite being very accurate in single phase conditions, fails to accurately measure two-phase flows. It poses a complex fluid-structure interaction problem in case of two-phase operation; there is a scarcity of theoretical models...

  12. Probabilistic Forecast Calibration Using ECMWF and GFS Ensemble Reforecasts. Part I: Two-Meter Temperatures

    E-Print Network [OSTI]

    Hamill, Tom

    Probabilistic Forecast Calibration Using ECMWF and GFS Ensemble Reforecasts. Part I: Two-Meter Temperatures RENATE HAGEDORN European Centre for Medium-Range Weather Forecasts, Reading, United Kingdom THOMAS for Medium-Range Weather Forecasts (ECMWF) produced a reforecast dataset for a 2005 version of their ensemble

  13. Embedded Firmware Diversity for Smart Electric Meters Stephen McLaughlin, Dmitry Podkuiko, Adam Delozier

    E-Print Network [OSTI]

    McDaniel, Patrick Drew

    .g., consumer-generated wind and solar energy. Smart meters are the consumer conduit to the grid. Re- placing in use today and hundreds of millions more to be deployed in the next few years. These low-cost ( $50 systems offers substantial benefits for society; increased efficien- cies and information availability can

  14. Economic Implications of Net Metering for Stationary and Motor Vehicle Fuel Cell Systems in California

    E-Print Network [OSTI]

    Kammen, Daniel M.

    PWP-092 Economic Implications of Net Metering for Stationary and Motor Vehicle Fuel Cell Systems emissions, and petroleum use from motor vehicles, fuel cell vehicles (FCVs) could also act as distributed Fuel Cell Systems in California January 31, 2002 Dr. Timothy E. Lipman Ms. Jennifer L. Edwards Prof

  15. Electrical Usage Profiling The roll out of Smart Meters between now and 2020 will allow

    E-Print Network [OSTI]

    Aickelin, Uwe

    Electrical Usage Profiling The roll out of Smart Meters between now and 2020 will allow greatly increased analysis of a household's electricity usage and allow customised interventions in order in order to explore flexibility during the early evening peak usage time (4pm to 8pm). For each household

  16. HeatProbe: A Thermal-based Power Meter for Accounting Disaggregated Electricity Usage

    E-Print Network [OSTI]

    Ouhyoung, Ming

    HeatProbe: A Thermal-based Power Meter for Accounting Disaggregated Electricity Usage Bo-Jhang Ho1 Technology Innovation, Academia Sinica 128, Sec. 2, Academia Rd., Taipei 115, Taiwan {cwyou, mschen}@citi.sinica.edu.tw ABSTRACT To promote energy-saving behavior, disaggregating elec- tricity usage is critical for increasing

  17. 1128 volume 27 number 12 december 2009 nature biotechnology square meter per day of algae containing

    E-Print Network [OSTI]

    Cai, Long

    1128 volume 27 number 12 december 2009 nature biotechnology square meter per day of algae, such as triglycerides from algae or cellulosic biomass from higher plants, as feedstocks for biofuel production. The algal program sought to develop high-oil-content algae that grow at very fast rates. In our report

  18. Optimal Integration of Renewable Energy Resources in Data Centers with Behind-the-Meter Renewable Generator

    E-Print Network [OSTI]

    Mohsenian-Rad, Hamed

    1 Optimal Integration of Renewable Energy Resources in Data Centers with Behind-the-Meter Renewable-- Renewable energy resources, such as wind and solar power, are rapidly becoming generation technologies-temporal variations, the integration of renewable energy resources is usually very challenging. Some of the previously

  19. Micro-meter Crack Response to Rock Blast Vibrations, Wind Gusts & Weather Effects

    E-Print Network [OSTI]

    Micro-meter Crack Response to Rock Blast Vibrations, Wind Gusts & Weather Effects C. H. Dowding,1 effects. These measurements substantiate the conservancy of the 12.5 mm/s (0.5 in./s) blasting vibration blasting. Measurements in this case study now extend weather effects to include wind. While it has been

  20. Energy-Harvesting Thermoelectric Sensing for Unobtrusive Water and Appliance Metering

    E-Print Network [OSTI]

    Dutta, Prabal

    in homes and buildings pro- vides a promising technique for addressing the unmaintain- able energy's energy footprint. A myriad of sensor designs and systems collect data on partic- ular building aspects Introduction Detailed energy metering in buildings allows homeown- ers, tenants, and building managers