National Library of Energy BETA

Sample records for alpha emitting isotopes

  1. Direct analysis of air filter samples for alpha emitting isotopes

    SciTech Connect (OSTI)

    Mohagheghi, A.H.; Ghanbari, F.; Ebara, S.B.; Enghauser, M.E. [Sandia National Labs., Albuquerque, NM (United States); Bakhtiar, S.N. [Westinghouse WIPP, Carlsbad, NM (United States)

    1997-04-01

    The traditional method for determination of alpha emitting isotopes on air filters has been to process the samples by radiochemical methods. However, this method is too slow for cases of incidents involving radioactive materials where the determination of personnel received dose is urgent. A method is developed to directly analyze the air filters taken from personal and area air monitors. The site knowledge is used in combination with alpha spectral information to identify isotopes. A mathematical function is developed to estimate the activity for each isotope. The strengths and weaknesses of the method are discussed.

  2. THE SPATIALLY RESOLVED H{alpha}-EMITTING WIND STRUCTURE OF P CYGNI

    SciTech Connect (OSTI)

    Balan, Aurelian; Tycner, C.; Zavala, R. T.; Benson, J. A.; Hutter, D. J.; Templeton, M. E-mail: c.tycner@cmich.ed E-mail: jbenson@nofs.navy.mi E-mail: matthewt@aavso.or

    2010-06-15

    High spatial resolution observations of the H{alpha}-emitting wind structure associated with the luminous blue variable star P Cygni were obtained with the Navy Prototype Optical Interferometer. These observations represent the most comprehensive interferometric data set on P Cyg to date. We demonstrate how the apparent size of the H{alpha}-emitting region of the wind structure of P Cyg compares between the 2005, 2007, and 2008 observing seasons and how this relates to the H{alpha} line spectroscopy. Using the data sets from 2005, 2007, and 2008 observing seasons, we fit a circularly symmetric Gaussian model to the interferometric signature from the H{alpha}-emitting wind structure of P Cyg. Based on our results, we conclude that the radial extent of the H{alpha}-emitting wind structure around P Cyg is stable at the 10% level. We also show how the radial distribution of the H{alpha} flux from the wind structure deviates from a Gaussian shape, whereas a two-component Gaussian model is sufficient to fully describe the H{alpha}-emitting region around P Cyg.

  3. Progress on Production of Alpha-emitting Radioisotopes for Cancer Therapy |

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    U.S. DOE Office of Science (SC) Progress on Production of Alpha-emitting Radioisotopes for Cancer Therapy Nuclear Physics (NP) NP Home About Research Facilities Science Highlights Benefits of NP Funding Opportunities Nuclear Science Advisory Committee (NSAC) Community Resources Contact Information Nuclear Physics U.S. Department of Energy SC-26/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-3613 F: (301) 903-3833 E: Email Us More Information » 07.01.12

  4. Lyman Alpha Emitting Galaxies at 2 < z < 3: Towards a Calibrated Probe of Dark Energy

    SciTech Connect (OSTI)

    Caryl Gronwall

    2012-12-03

    The goal of this project was to establish the physical properties of Ly{alpha} emitting galaxies from redshifts of 2 to 3 in order to better calibrate the use of LAEs as probes of the large scale structure of the universe for upcoming dark energy experiments, such as the Hobby Eberly Telescope Dark Energy Experiment (HETDEX). We have obtained narrow-band imaging of the Extended Chandra Deep Field South (ECDF-S) in two different narrow-band filters centered at Ly{alpha} at z=2.1 and 3.1. The resulting of samples of LAEs were used to determine the LAE luminosity function, equivalent width distribution and clustering properties (bias) of LAEs at these redshifts. While the results from the ECDF-S appear robust, they are based on a single field. To explore the effects of cosmic variance and galaxy environment on the physical properties of LAEs, we have also obtained narrow-band data at both redshifts (z = 2:1 and 3:1) in three additional fields (SDSS 1030+-05, the Extended Hubble Deep Field South, and CW 1255+01). The narrow-band imaging data has been reduced and LAE catalogs are being generated. We have calculated preliminary luminosity functions, equivalent width distributions, and clustering properties. We have also obtained follow-up spectroscopy in the optical (using VLT/FORS) and in the near-infrared (using Magellan/MMIRS). Since individual LAEs have too little S/N to enable meaningful fits for stellar population parameters, our previous work has analyzed stacked Spectral Energy Distributions (SEDs). SED fitting was performed on several subsets of LAEs selected by their rest-UV luminosity, UV spectral slope, Ly alpha luminosity, Equivalent Width, or rest-optical (IRAC) luminosity.

  5. Plutonium isotopic assay from alpha spectroscopy: A progress report

    SciTech Connect (OSTI)

    Baran, D.T.

    1995-12-31

    The Non-Destructive Assay (NDA) group at New Brunswick Laboratory (NBL) continues to develop and refine a computer program ALPHAFIT, a sophisticated peak-fitting routine for use in determining the isotopic abundances of Pu and U samples. The program uses up to seven parameters per peak fit and up to 12 peaks per region of interest to de-convolute typical complicated Pu a spectra. Preliminary results show decent fits for major peaks in the spectrum and calculated isotopic abundances of the major isotopes to {+-} 4%.

  6. Measurement and analysis of. cap alpha. particles emitted in reactions of /sup 12/C bombarding /sup 12/C, /sup 27/Al, and /sup nat/Ca

    SciTech Connect (OSTI)

    XIE Yuan-xiang; WU Guo-hua; ZHU Yong-tai; MIAO Rong-zhi; FONG En-pu; YIN Xu; MIAO He-bing; CAI Jing-xiang; SHEN Wen-qing; SUN Shu-ming

    1985-10-01

    The energy spectra and angular distributions of the ..cap alpha.. particles emitted in the reactions of 69.5 MeV /sup 12/C bombarding /sup 12/C, /sup 27/Al, and /sup nat/Ca have been measured and analyzed using the fast-particle exciton model. The contribution from the equilibrium and pre-equilibrium ..cap alpha.. emissions is calculated to be 89%, 81%, and 83% of the total ..cap alpha.. yields for the three reactions, respectively, where the pre-equilibrium ..cap alpha.. emissions are 11%, 14%, and 16%, respectively. A small contribution comes from other reaction mechanisms.

  7. Note: Real time optical sensing of alpha-radiation emitting radioactive aerosols based on solid state nuclear track detector

    SciTech Connect (OSTI)

    Kulkarni, A.; Bak, M. S. E-mail: moonsoo@skku.edu; Ha, S.; Joshirao, P.; Manchanda, V.; Kim, T. E-mail: moonsoo@skku.edu

    2015-06-15

    A sensitive radioactive aerosols sensor has been designed and developed. Its design guidance is based on the need for a low operational cost and reliable measurements to provide daily aerosol monitoring. The exposure of diethylene-glycol bis (allylcarbonate) to radiation causes modification of its physico-chemical properties like surface roughness and reflectance. In the present study, optical sensor based on the reflectance measurement has been developed with an aim to monitor real time presence of alpha radioactive aerosols emitted from thorium nitrate hydrate. The results shows that the fabricated sensor can detect 0.0157 kBq to 0.1572 kBq of radio activity by radioactive aerosols generated from (Th(NO{sub 3}){sub 4} ⋅ 5H{sub 2}O) at 0.1 ml/min flow rate. The proposed instrument will be helpful to monitor radioactive aerosols in/around a nuclear facility, building construction sites, mines, and granite polishing factories.

  8. RAPID DETERMINATION OF 237 NP AND PU ISOTOPES IN WATER BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY AND ALPHA SPECTROMETRY

    SciTech Connect (OSTI)

    Maxwell, S.; Jones, V.; Culligan, B.; Nichols, S.; Noyes, G.

    2010-06-23

    A new method that allows rapid preconcentration and separation of plutonium and neptunium in water samples was developed for the measurement of {sup 237}Np and Pu isotopes by inductively-coupled plasma mass spectrometry (ICP-MS) and alpha spectrometry; a hybrid approach. {sup 238}U can interfere with {sup 239}Pu measurement by ICP-MS as {sup 238}UH{sup +} mass overlap and {sup 237}Np via peak tailing. The method provide enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then moving Pu to DGA resin for additional removal of uranium. The decontamination factor for uranium from Pu is almost 100,000 and the decontamination factor for U from Np is greater than 10,000. This method uses stacked extraction chromatography cartridges and vacuum box technology to facilitate rapid separations. Preconcentration is performed using a streamlined calcium phosphate precipitation method. Purified solutions are split between ICP-MS and alpha spectrometry so that long and short-lived Pu isotopes can be measured successfully. The method allows for simultaneous extraction of 20 samples (including QC samples) in 4 to 6 hours, and can also be used for emergency response. {sup 239}Pu, {sup 242}Pu and {sup 237}Np were measured by ICP-MS, while {sup 236}Pu, {sup 238}Pu, and {sup 239}Pu were measured by alpha spectrometry.

  9. Isotopes

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Office of Science » Nuclear Physics » Isotopes Isotopes Isotopes produced at Los Alamos National Laboratory are saving lives, advancing cutting-edge research and keeping the U.S. safe. Get Expertise Eva Birnbaum (505) 665-7167 Email Wolfgang Runde (505) 667-3350 Email Isotope Production and Applications isotopes Isotopes produced at IPF are critical for medical diagnosis and disease treatment. These positron emission tomography images were made possible using isotopes produced at LANL.

  10. Isotopes

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Eva Birnbaum (505) 665-7167 Email Wolfgang Runde (505) 667-3350 Email Isotope Production and Applications isotopes Isotopes produced at IPF are critical for medical diagnosis and ...

  11. Alpha Radiation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Basics of Radiation Gamma Radiation and X-Rays Beta Radiation Alpha Radiation Irradiation Radioactive Contamination Definitions Detection Measurement Safety Around Radiation Sources Types of Radiation Exposure Managing Radiation Emergencies Basics of Radiation Characteristics of Alpha Radiation 1. Alpha radiation is not able to penetrate skin. 2. Alpha-emitting materials can be harmful to humans if the materials are inhaled, swallowed, or absorbed through open wounds. 3. A variety of instruments

  12. Stark broadening for diagnostics of the electron density in non-equilibrium plasma utilizing isotope hydrogen alpha lines

    SciTech Connect (OSTI)

    Yang, Lin; Tan, Xiaohua; Wan, Xiang; Chen, Lei; Jin, Dazhi; Qian, Muyang; Li, Gongping

    2014-04-28

    Two Stark broadening parameters including FWHM (full width at half maximum) and FWHA (full width at half area) of isotope hydrogen alpha lines are simultaneously introduced to determine the electron density of a pulsed vacuum arc jet. To estimate the gas temperature, the rotational temperature of the C{sub 2} Swan system is fit to 2500??100?K. A modified Boltzmann-plot method with b{sub i}-factor is introduced to determine the modified electron temperature. The comparison between results of atomic and ionic lines indicates the jet is in partial local thermodynamic equilibrium and the electron temperature is close to 13?000??400?K. Based on the computational results of Gig-Card calculation, a simple and precise interpolation algorithm for the discrete-points tables can be constructed to obtain the traditional n{sub e}-T{sub e} diagnostic maps of two Stark broadening parameters. The results from FWHA formula by the direct use of FWHM?=?FWHA and these from the diagnostic map are different. It can be attributed to the imprecise FWHA formula form and the deviation between FWHM and FWHA. The variation of the reduced mass pair due to the non-equilibrium effect contributes to the difference of the results derived from two hydrogen isotope alpha lines. Based on the Stark broadening analysis in this work, a corrected method is set up to determine n{sub e} of (1.10??0.08)??10{sup 21}?m{sup ?3}, the reference reduced mass ?{sub 0} pair of (3.30??0.82 and 1.65??0.41), and the ion kinetic temperature of 7900??1800?K.

  13. Anisotropic alpha decay from oriented odd-mass isotopes of some light actinides

    SciTech Connect (OSTI)

    Berggren, T. )

    1994-11-01

    Half-lives and anisotropies in the [alpha] decay of [sup 205,207,209]Rn, [sup 219]Rn, [sup 221]Fr, [sup 227,229]Pa, and [sup 229]U have been calculated using the reaction-theoretical formalism proposed by Jackson and Rhoades-Brown and adapted for axially symmetric deformed nuclei by Berggren and Olanders. The possibility of octupole deformation has been taken into account. In addition, a variant of triaxial octupole deformation has been considered tentatively in the case of [sup 227]Pa and [sup 229]Pa.

  14. Science on the Hill: Isotope research opens new possibilities for cancer

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    treatment Isotope research opens new possibilities for cancer treatment Isotope research opens new possibilities for cancer treatment A new study at LANL and in collaboration with Stanford Synchrotron Radiation Lightsource greatly improves scientists' understanding of the element actinium whose short offers opportunity for new alpha-emitting drugs to treat cancer. August 22, 2016 Molecule Hot cell facility Isotope research opens new possibilities for cancer treatment A new study at Los

  15. Treatment of HER2-Expressing Breast Cancer and Ovarian Cancer Cells With Alpha Particle-Emitting {sup 227}Th-Trastuzumab

    SciTech Connect (OSTI)

    Heyerdahl, Helen; Krogh, Cecilie; Borrebaek, Jorgen; Larsen, Asmund; Dahle, Jostein

    2011-02-01

    Purpose: To evaluate the cytotoxic effects of low-dose-rate alpha particle-emitting radioimmunoconjugate {sup 227}Th-p-isothiocyanato-benzyl-DOTA-trastuzumab ({sup 227}Th-trastuzumab [where DOTA is 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid]) internalized by breast and ovarian cancer cell lines in order to assess the potential of {sup 227}Th-trastuzumab as a therapeutic agent against metastatic cancers that overexpress the HER2 oncogene. Methods and Materials: Clonogenic survival and cell growth rates of breast cancer cells treated with {sup 227}Th-trastuzumab were compared with rates of cells treated with nonbinding {sup 227}Th-rituximab, cold trastuzumab, and X-radiation. Cell growth experiments were also performed with ovarian cancer cells. Cell-associated radioactivity was measured at several time points, and the mean radiation dose to cells was calculated. Results: SKBR-3 cells got 50% of the mean absorbed radiation dose from internalized activity and 50% from cell surface-bound activity, while BT-474 and SKOV-3 cells got 75% radiation dose from internalized activity and 25% from cell surface-bound activity. Incubation of breast cancer cells with 2.5 kBq/ml {sup 227}Th-trastuzumab for 1 h at 4{sup o}C, followed by washing, resulted in mean absorbed radiation doses of 2 to 2.5 Gy. A dose-dependent inhibition of cell growth and an increase in apoptosis were induced in all cell lines. Conclusions: Clinically relevant activity concentrations of {sup 227}Th-trastuzumab induced a specific cytotoxic effect in three HER2-expressing cell lines. The cytotoxic effect of {sup 227}Th-trastuzumab was higher than that of single-dose X-radiation (relative biological effectiveness = 1.2). These results warrant further studies of treatment of breast cancer and ovarian cancer with {sup 227}Th-trastuzumab.

  16. Behavior of intruder based states in light Bi and Tl isotopes: the study of {sup 187 Bi} {alpha} decay

    SciTech Connect (OSTI)

    Batchelder, J.C.; Zganjar, E.F.

    1997-01-01

    Intruder state excitation energies in odd-mass nuclei just outside a closed proton shell plotted versus neutron number generally exhibit parabola-shaped curves with minima near neutron mid-shells. The Bi isotopes, however, do not seem to follow this trend. Recent experiments performed at Argonne National Laboratory have identified the previously unobserved {sup 187}Bi ground state (h{sub 9/2}) to {sup 183}TI ground state s{sub 1/2} {alpha} transition. Its energy when combined with those of two earlier known transitions, namely {sup 187}Bi (h{sub 9/2}) {yields} {sup 183m}Tl (h{sub 9/2}) and {sup 187m}Bi (s{sub 1/2}) {yields} {sup 183}Tl(s{sub 1/2}), establishes the excitation energies of the {sup 183m}Tl and {sup 187m}Bi to be 620(20) keV and 110(20) keV, respectively. This value for {sup 187m}Bi is 80 keV lower than the excitation energy of the same intruder level in {sup 189}Bi. Implications of this result with respect to intruder-state systematics are discussed.

  17. Isolation and Puification of Uranium Isotopes for Measurement by Mass-Spectrometry (233, 234, 235, 236, 238U) and Alpha Spectrometry (232U)

    SciTech Connect (OSTI)

    Marinelli, R; Hamilton, T; Brown, T; Marchetti, A; Williams, R; Tumey, S

    2006-05-30

    This report describes a standardized methodology used by researchers from the Center for Accelerator Mass Spectrometry (CAMS) (Energy and Environment Directorate) and the Environmental Radiochemistry Group (Chemistry and Materials Science Directorate) at the Lawrence Livermore National Laboratory (LLNL) for the full isotopic analysis of uranium from solution. The methodology has largely been developed for use in characterizing the uranium composition of selected nuclear materials but may also be applicable to environmental studies and assessments of public, military or occupational exposures to uranium using in-vitro bioassay monitoring techniques. Uranium isotope concentrations and isotopic ratios are measured using a combination of Multi Collector Inductively Coupled Plasma Mass Spectrometry (MC ICP-MS), Accelerator Mass Spectrometry (AMS) and Alpha Spectrometry.

  18. The Use of Isotope Dilution Alpha Spectrometry and Liquid Scintillation Counting to Determine Radionuclides in Environmental Samples

    SciTech Connect (OSTI)

    Bylyku, Elida

    2009-04-19

    In Albania in recent years it has been of increasing interest to determine various pollutants in the environment and their possible effects on human health. The radiochemical procedure used to identify Pu, Am, U, Th, and Sr radioisotopes in soil, sediment, water, coal, and milk samples is described. The analysis is carried out in the presence of respective tracer solutions and combines the procedure for Pu analysis based on anion exchange, the selective method for Sr isolation based on extraction chromatography using Sr-Spec resin, and the application of the TRU-Spec column for separation of Am fraction. An acid digestion method has been applied for the decomposition of samples. The radiochemical procedure involves the separation of Pu from Th, Am, and Sr by anion exchange, followed by the preconcentration of Am and Sr by coprecipitation with calcium oxalate. Am is separated from Sr by extraction chromatography. Uranium is separated from the bulk elements by liquid-liquid extraction using UTEVA registered resin. Thin sources for alpha spectrometric measurements are prepared by microprecipitation with NdF3. Two International Atomic Energy Agency reference materials were analyzed in parallel with the samples.

  19. Background canceling surface alpha detector

    DOE Patents [OSTI]

    MacArthur, D.W.; Allander, K.S.; Bounds, J.A.

    1996-06-11

    A background canceling long range alpha detector which is capable of providing output proportional to both the alpha radiation emitted from a surface and to radioactive gas emanating from the surface. The detector operates by using an electrical field between first and second signal planes, an enclosure and the surface or substance to be monitored for alpha radiation. The first and second signal planes are maintained at the same voltage with respect to the electrically conductive enclosure, reducing leakage currents. In the presence of alpha radiation and radioactive gas decay, the signal from the first signal plane is proportional to both the surface alpha radiation and to the airborne radioactive gas, while the signal from the second signal plane is proportional only to the airborne radioactive gas. The difference between these two signals is proportional to the surface alpha radiation alone. 5 figs.

  20. Background canceling surface alpha detector

    DOE Patents [OSTI]

    MacArthur, Duncan W.; Allander, Krag S.; Bounds, John A.

    1996-01-01

    A background canceling long range alpha detector which is capable of providing output proportional to both the alpha radiation emitted from a surface and to radioactive gas emanating from the surface. The detector operates by using an electrical field between first and second signal planes, an enclosure and the surface or substance to be monitored for alpha radiation. The first and second signal planes are maintained at the same voltage with respect to the electrically conductive enclosure, reducing leakage currents. In the presence of alpha radiation and radioactive gas decay, the signal from the first signal plane is proportional to both the surface alpha radiation and to the airborne radioactive gas, while the signal from the second signal plane is proportional only to the airborne radioactive gas. The difference between these two signals is proportional to the surface alpha radiation alone.

  1. Alpha Backgrounds for HPGe Detectors in Neutrinoless Double-Beta Decay Experiments

    SciTech Connect (OSTI)

    Johnson, R. A. [University of Washington, Seattle; Burritt, T. H. [University of Washington, Seattle; Elliott, S. R. [Los Alamos National Laboratory (LANL); Gehman, V. M. [Los Alamos National Laboratory (LANL); Guiseppe, V.E. [University of South Dakota; Wilkerson, J. F. [UNC/Triangle Univ. Nucl. Lab, Durham, NC/ORNL

    2012-01-01

    The Majorana Experiment will use arrays of enriched HPGe detectors to search for the neutrinoless double-beta decay of 76Ge. Such a decay, if found, would show lepton-number violation and confirm the Majorana nature of the neutrino. Searches for such rare events are hindered by obscuring backgrounds which must be understood and mitigated as much as possible. A potentially important background contribution to this and other double-beta decay experiments could come from decays of alpha-emitting isotopes in the 232Th and 238U decay chains on or near the surfaces of the detectors. An alpha particle emitted external to an HPGe crystal can lose energy before entering the active region of the detector, either in some external-bulk material or within the dead region of the crystal. The measured energy of the event will only correspond to a partial amount of the total kinetic energy of the alpha and might obscure the signal from neutrinoless double-beta decay. A test stand was built and measurements were performed to quantitatively assess this background. We present results from these measurements and compare them to simulations using Geant4. These results are then used to measure the alpha backgrounds in an underground detector in situ. We also make estimates of surface contamination tolerances for double-beta decay experiments using solid-state detectors.

  2. light-emitting diode

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Cost The high-brightness, rapidly pulsed, multicolor light-emitting diode (LED) driver delivers lighting performance that exceeds that of conventional (laserarc-light) sources ...

  3. Isotope separation apparatus and method

    DOE Patents [OSTI]

    Feldman, Barry J.

    1985-01-01

    The invention relates to an improved method and apparatus for laser isotope separation by photodeflection. A molecular beam comprising at least two isotopes to be separated intersects, preferably substantially perpendicular to one broad side of the molecular beam, with a laser beam traveling in a first direction. The laser beam is reflected back through the molecular beam, preferably in a second direction essentially opposite to the first direction. Because the molecules in the beam occupy various degenerate energy levels, if the laser beam comprises chirped pulses comprising selected wavelengths, the laser beam will very efficiently excite substantially all unexcited molecules and will cause stimulated emission of substantially all excited molecules of a selected one of the isotopes in the beam which such pulses encounter. Excitation caused by first direction chirped pulses moves molecules of the isotope excited thereby in the first direction. Stimulated emission of excited molecules of the isotope is brought about by returning chirped pulses traveling in the second direction. Stimulated emission moves emitting molecules in a direction opposite to the photon emitted. Because emitted photons travel in the second direction, emitting molecules move in the first direction. Substantial molecular movement of essentially all the molecules containing the one isotope is accomplished by a large number of chirped pulse-molecule interactions. A beam corer collects the molecules in the resulting enriched divergent portions of the beam.

  4. Code System for Analyzing Ge and Alpha-Particle Detector Spectra.

    Energy Science and Technology Software Center (OSTI)

    1992-06-29

    Version 00 GRPANL (GRouP ANaLysis) is a suite of programs which analyzes and interprets regions of germanium and alpha-particle detector pulse-height spectra. GRPANL is the main peak-fitting program; the other programs included are used in conjunction with GRPANL. GRPANL is particularly useful for accurately deconvoluting and interpreting complex clusters of peaks in a spectrum. GRPANL fits peaks in specified regions of a gamma-ray, x-ray, or alpha-particle spectrum, calculates their energies and intensities, and optionally calculatesmore » the photon emission rates for the sample from which they were emitted. It can also identify and measure isotopes in a sample. GRPANL output can be immediately analyzed for quantitative isotopic assays or stored in an intermediate data file. The other programs are EDIGRP, LIBRY, and GEVAL. EDISRP (EDIt GRouP) creates and edits an analysis control file that contains input parameters and analysis options for spectral regions analyzed by GRPANL; users can repeat or modify an analysis without retyping input. LIBRY (LIBRarY) assembles and cross references selected nuclear decay scheme data and stores it in decay scheme data files for use by GRPANL and GEVAL. GEVAL (Gamma ray EVALuation) uses these data files along with GRPANL intermediate results to identify isotopes, calculate their abundance in a sample, and print the corresponding disintegration rates and abundances at counting and zero times.« less

  5. Isotope separation apparatus and method

    DOE Patents [OSTI]

    Cotter, Theodore P.

    1982-12-28

    The invention relates to a method and apparatus for laser isotope separation by photodeflection. A molecular beam comprising at least two isotopes to be separated intersects, preferable substantially perpendicular to one broad side of the molecular beam, with a laser beam traveling in a first direction. The laser beam is reflected back through the molecular beam, preferably in a second direction essentially opposite to the first direction. The laser beam comprises .pi.-pulses of a selected wavelength which excite unexcited molecules, or cause stimulated emission of excited molecules of one of the isotopes. Excitation caused by first direction .pi.-pulses moves molecules of the isotope excited thereby in the first direction. Stimulated emission of excited molecules of the isotope is brought about by returning .pi.-pulses traveling in the second direction. Stimulated emission moves emitting molecules in a direction opposite to the photon emitted. Because emitted photons travel in the second direction, emitting molecules move in the first direction. Substantial molecular movement is accomplished by a large number of .pi.-pulse-molecule interactions. A beam corer collects the molecules in the resulting enriched divergent portions of the beam.

  6. Light emitting ceramic device

    DOE Patents [OSTI]

    Valentine, Paul; Edwards, Doreen D.; Walker, Jr., William John; Slack, Lyle H.; Brown, Wayne Douglas; Osborne, Cathy; Norton, Michael; Begley, Richard

    2010-05-18

    A light-emitting ceramic based panel, hereafter termed "electroceramescent" panel, is herein claimed. The electroceramescent panel is formed on a substrate providing mechanical support as well as serving as the base electrode for the device. One or more semiconductive ceramic layers directly overlay the substrate, and electrical conductivity and ionic diffusion are controlled. Light emitting regions overlay the semiconductive ceramic layers, and said regions consist sequentially of a layer of a ceramic insulation layer and an electroluminescent layer, comprised of doped phosphors or the equivalent. One or more conductive top electrode layers having optically transmissive areas overlay the light emitting regions, and a multi-layered top barrier cover comprising one or more optically transmissive non-combustible insulation layers overlay said top electrode regions.

  7. Isotope Science

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Science and Production 35 years of experience in isotope production, processing, and applications. Llllll Committed to the safe and reliable production of radioisotopes, products, and services. Contact: Kevin John LANL Isotope Program Manager kjohn@lanl.gov 505-667-3602 Sponsored by the Department of Energy National Isotope Program http://www.nuclear.energy.gov/isotopes/nelsotopes2a.html Isotopes for Environmental Science Isotopes produced at Los Alamos National Laboratory are used as

  8. Methods for the synthesis and polymerization of .alpha.,.alpha.'-dihalo-p-xylenes

    DOE Patents [OSTI]

    Ferraris, John P.; Neef, Charles J.

    2002-07-30

    The present invention describes an improved method for the polymerization of .alpha.,.alpha.-dihalo-p-xylene's such as the .alpha.,.alpha.'-dihalo-2-methoxy-5-(2-ethylhexyloxy)-xylene's. The procedure for synthesis is based on the specific order of addition of reagents and the use of an anionic initiator that allows control of the molecular weight of the polymer. The molecular weight control allows processability of the polymer which is important for its utility in applications including in light-emitting-diodes, field effect transistors and photovoltaic devices.

  9. Isotopes Products

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Other isotopes that have recently shipped from LANL's isotope program include cadmium-109 (X-ray fluorescence sources), arsenic-72 (medical research), and sodium-22 (PET sources).

  10. Laser isotope purification of lead for use in semiconductor chip interconnects

    SciTech Connect (OSTI)

    Scheibner, K.; Haynam, C.; Worden, E.; Esser, B.

    1996-03-19

    Lead, used throughout the electronics industries, typically contains small amounts of radioactive {sup 210}Pb (a daughter product of the planets ubiquitous {sup 238}U) whose {sup 210}Po daughter emits an {alpha}-particle that is known to cause soft errors in electronic circuits. The {sup 210}Pb is not separable by chemical means. This paper describes the generic Atomic Vapor Laser Isotope Separation (AVLIS) process developed at the Lawrence Livermore National Laboratory (LLNL) over the last 20 years, with particular emphasis on recent efforts to develop the process physics and component technologies required to remove the offending {sup 210}Pb using lasers. We have constructed a developmental facility that includes a process laser development area and a test bed for the vaporizer and ion and product collectors. We will be testing much of the equipment and demonstrating pilot scale AVLIS on a surrogate material later this year. Detection of the very low alpha emission even from commercially available low-alpha lead is challenging. LLNL`s detection capabilities will be described. The goal of the development of lead purification technology is to demonstrate the capability in FY97, and to deploy a production machine capable of up to several MT/y of isotopically purified material, possible beginning in FY98.

  11. Laser isotope purification of lead for use in semiconductor chip interconnects

    SciTech Connect (OSTI)

    Scheibner, K.; Haynam, C.; Worden, E.; Esser, B.

    1996-02-01

    Lead, used throughout the electronics industries, typically contains small amounts of radioactive {sup 210}Pb (a daughter product of the planet`s ubiquitous {sup 210}U) whose {sup 210}Po daughter emits and {alpha}-particle that is known to cause soft errors in electronic circuits. The {sup 210}Pb is not easily separable by chemical means. This paper describes the generic Atomic Vapor Laser Isotope Separation (AVLIS) process developed at the Lawrence Livermore National Laboratory (LLNL) over the last 20 years, with particular emphasis on recent efforts to develop the process physics and component technologies required to remove the offending {sup 210}Pb using lasers. We have constructed a developmental facility that includes a process laser development area and a test bed for the vaporizer and ion and product collectors. We will be testing much of the equipment and demonstrating pilot-scale AVLIS on a surrogate material later this year. Detection of the very low alpha emission even from commercially available low-alpha lead is challenging. LLNL`s detection capabilities will be described. The goal of the development of lead purification technology is to demonstrate the capability in FY97, and to begin filling orders of up to several MT/y of isotopically purified material in FY98.

  12. Transport of Radioactive Material by Alpha Recoil

    SciTech Connect (OSTI)

    Icenhour, A.S.

    2005-05-19

    The movement of high-specific-activity radioactive particles (i.e., alpha recoil) has been observed and studied since the early 1900s. These studies have been motivated by concerns about containment of radioactivity and the protection of human health. Additionally, studies have investigated the potential advantage of alpha recoil to effect separations of various isotopes. This report provides a review of the observations and results of a number of the studies.

  13. Use of MCNPX for Alpha Spectrometry Simulations of a Continuous Air Monitor

    SciTech Connect (OSTI)

    Robert Hayes, Craig Marianno

    2007-01-01

    The purpose of this study was to determine if the alpha energy spectrum in a Passive Implanted Planar Silicon (PIPS) detector, as modeled by MCNPX [1], can be used to design a radon stripping algorithm for a continuous air monitor (CAM). This stripping algorithm would be employed to discriminate naturally occurring radioisotopes from the anthropogenic for nuclear safety -related applications. It is hoped that using an algorithm based on MCNPX simulations, the CAM will not be prone to false alarms when radon levels are dynamic as identified in other CAM systems [2,3]. This work is focused on the design of the next generation air particulate detector (NGAPD) for the United States Navy. The primary isotope of interest is Co-60. This radionuclide emits a beta with an average energy of 96 keV. Therefore, once deposited on the CAM filter, it will produce a beta continuum seen by the PIPS detector. In addition, as radon progeny is deposited on the air filter, these will give rise to characteristic alpha peaks and a beta continuum. This is primarily an issue in port-or land-based applications. Ultimately, measurement of a radon alpha spectrum is desired to predict the amount of beta activity which would be measured from the radon progeny decay chains. All excess beta activity could then be attributed to anthropogenic sources once the radon progeny contributions have been stripped out.

  14. Accelerator Production of {sup 225}Ac For Alpha-Immunotherapy

    SciTech Connect (OSTI)

    Weidner, J. W.; Nortier, F. M.; Bach, H. T.; John, K. D.; Couture, A.; Ullmann, J. L.; Fassbender, M. E.; Goff, G. S.; Taylor, W.; Valdez, F.; Wolfsberg, L. E.; Cisneros, M.; Dry, D.; Gallegos, M.; Gritzo, R.; Bitteker, L. J.; Wender, S.; Baty, R. S.

    2011-06-01

    {sup 225}Ac has tremendous potential for the treatment of metastatic cancer due to the four alpha-particles emitted during its decay to stable {sup 209}Bi. Additionally, it is one of the few alpha-emitters being considered for clinical trials. The anticipated {sup 225}Ac demand for these trials is expected to far exceed the annual worldwide supply of approximately 1,000 mCi/yr. Consequently, the DOE Office of Science has funded investigations into accelerator-based production of {sup 225}Ac. Existing {sup 232}Th(p,x){sup 225}Ac cross section data indicate that up to 480 mCi/day of {sup 225}Ac could be created by bombarding a thick target of natural thorium with 100 MeV protons at the Los Alamos Isotope Production Facility. To verify these predictions, experiments are underway at the Los Alamos Neutron Science Center to measure the {sup 232}Th(p,x){sup 225}Ac production cross sections for protons in the energy range 40-200 MeV, and at 800 MeV. For 800 MeV protons, preliminary results indicate that the {sup 225}Ac production cross section is 12.4{+-}0.6 mb and the {sup 225}Ra production cross section is 3.2{+-}0.2 mb. Moreover, preliminary results suggest that the {sup 227}Ac production cross section is 16{+-}1 mb. Experiments to measure these same cross sections at proton energies below 200 MeV are planned for the last half of calendar year 2010.

  15. Isotope separation

    DOE Patents [OSTI]

    Bartlett, Rodney J.; Morrey, John R.

    1978-01-01

    A method and apparatus is described for separating gas molecules containing one isotope of an element from gas molecules containing other isotopes of the same element in which all of the molecules of the gas are at the same electronic state in their ground state. Gas molecules in a gas stream containing one of the isotopes are selectively excited to a different electronic state while leaving the other gas molecules in their original ground state. Gas molecules containing one of the isotopes are then deflected from the other gas molecules in the stream and thus physically separated.

  16. Atmospheric Emitted Radiance Interferometer

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Gero, Jonathan; Ermold, Brian; Gaustad, Krista; Koontz, Annette; Hackel, Denny; Garcia, Raymond

    2005-01-01

    The atmospheric emitted radiance interferometer (AERI) is a ground-based instrument that measures the downwelling infrared radiance from the Earth’s atmosphere. The observations have broad spectral content and sufficient spectral resolution to discriminate among gaseous emitters (e.g., carbon dioxide and water vapor) and suspended matter (e.g., aerosols, water droplets, and ice crystals). These upward-looking surface observations can be used to obtain vertical profiles of tropospheric temperature and water vapor, as well as measurements of trace gases (e.g., ozone, carbon monoxide, and methane) and downwelling infrared spectral signatures of clouds and aerosols. The AERI is a passive remote sounding instrument, employing a Fourier transform spectrometer operating in the spectral range 3.3–19.2 μm (520–3020 cm-1) at an unapodized resolution of 0.5 cm-1 (max optical path difference of 1 cm). The extended-range AERI (ER-AERI) deployed in dry climates, like in Alaska, have a spectral range of 3.3–25.0 μm (400–3020 cm-1) that allow measurements in the far-infrared region. Typically, the AERI averages views of the sky over a 16-second interval and operates continuously.

  17. AVLIS enrichment of medical isotopes

    SciTech Connect (OSTI)

    Haynam, C.A.; Scheibner, K.F.; Stern, R.C.; Worden, E.F.

    1996-12-31

    Under the Sponsorship of the United states Enrichment Corporation (USEC), we are currently investigating the large scale separation of several isotopes of medical interest using atomic vapor isotope separation (AVLIS). This work includes analysis and experiments in the enrichment of thallium 203 as a precursor to the production of thallium 201 used in cardiac imaging following heart attacks, on the stripping of strontium 84 from natural strontium as precursor to the production of strontium 89, and on the stripping of lead 210 from lead used in integrated circuits to reduce the number of alpha particle induced logic errors.

  18. Isotope geochemistry

    SciTech Connect (OSTI)

    Cole, D.R.; Curtis, D.B.; DePaolo, D.J.; Gerlach, T.M.; Laul, J.C.; Shaw, H.; Smith, B.M.; Sturchio, N.C.

    1990-09-01

    This document represents the consensus of members of the ad hoc Committee on Isotope Geochemistry in the US Department of Energy; the committee is composed of researchers in isotope geochemistry from seven of the national laboratories. Information included in this document was presented at workshops at Lawrence Berkeley Laboratory (April 1989) and at Los Alamos National Laboratory (August 1989).

  19. Isotopes Products

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Isotopes Products Isotopes Products Isotopes produced at Los Alamos National Laboratory are saving lives, advancing cutting-edge research and keeping the U.S. safe. Products stress and rest Stress and rest Rb-82 PET images in a patient with dipyridamole stress-inducible lateral wall and apical ischemia. (http://www.fac.org.ar/scvc/llave/image/machac/machaci.htm#f2,3,4) Strontium-82 is supplied to our customers for use in Sr-82/Rb-82 generator technologies. The generators in turn are supplied to

  20. SciTech Connect: "light emitting diode"

    Office of Scientific and Technical Information (OSTI)

    light emitting diode" Find + Advanced Search Term Search Semantic Search Advanced Search All Fields: "light emitting diode" Semantic Semantic Term Title: Full Text:...

  1. Atomic line emission analyzer for hydrogen isotopes

    DOE Patents [OSTI]

    Kronberg, J.W.

    1993-03-30

    Apparatus for isotopic analysis of hydrogen comprises a low pressure chamber into which a sample of hydrogen is introduced and then exposed to an electrical discharge to excite the electrons of the hydrogen atoms to higher energy states and thereby cause the emission of light on the return to lower energy states, a Fresnel prism made at least in part of a material anomalously dispersive to the wavelengths of interest for dispersing the emitted light, and a photodiode array for receiving the dispersed light. The light emitted by the sample is filtered to pass only the desired wavelengths, such as one of the lines of the Balmer series for hydrogen, the wavelengths of which differ slightly from one isotope to another. The output of the photodiode array is processed to determine the relative amounts of each isotope present in the sample. Additionally, the sample itself may be recovered using a metal hydride.

  2. Atomic line emission analyzer for hydrogen isotopes

    DOE Patents [OSTI]

    Kronberg, James W.

    1993-01-01

    Apparatus for isotopic analysis of hydrogen comprises a low pressure chamber into which a sample of hydrogen is introduced and then exposed to an electrical discharge to excite the electrons of the hydrogen atoms to higher energy states and thereby cause the emission of light on the return to lower energy states, a Fresnel prism made at least in part of a material anomalously dispersive to the wavelengths of interest for dispersing the emitted light, and a photodiode array for receiving the dispersed light. The light emitted by the sample is filtered to pass only the desired wavelengths, such as one of the lines of the Balmer series for hydrogen, the wavelengths of which differ slightly from one isotope to another. The output of the photodiode array is processed to determine the relative amounts of each isotope present in the sample. Additionally, the sample itself may be recovered using a metal hydride.

  3. Atomic line emission analyzer for hydrogen isotopes

    DOE Patents [OSTI]

    Kronberg, J.W.

    1991-05-08

    Apparatus for isotopic analysis of hydrogen comprises a low pressure chamber into which a sample of hydrogen is introduced and then exposed to an electrical discharge to excite the electrons of the hydrogen atoms to higher energy states and thereby cause the emission of light on the return to lower energy states, a Fresnel prism made at least in part of a material anomalously dispersive to the wavelengths of interest for dispersing the emitted light, and a photodiode array for receiving the dispersed light. The light emitted by the sample is filtered to pass only the desired wavelengths, such as one of the lines of the Balmer series for hydrogen, the wavelengths of which differ slightly from one isotope to another. The output of the photodiode array is processed to determine the relative amounts of each isotope present in the sample. Additionally, the sample itself may be recovered using, a metal hydride.

  4. Infrared emitting device and method

    DOE Patents [OSTI]

    Kurtz, Steven R.; Biefeld, Robert M.; Dawson, L. Ralph; Howard, Arnold J.; Baucom, Kevin C.

    1997-01-01

    An infrared emitting device and method. The infrared emitting device comprises a III-V compound semiconductor substrate upon which are grown a quantum-well active region having a plurality of quantum-well layers formed of a ternary alloy comprising InAsSb sandwiched between barrier layers formed of a ternary alloy having a smaller lattice constant and a larger energy bandgap than the quantum-well layers. The quantum-well layers are preferably compressively strained to increase the threshold energy for Auger recombination; and a method is provided for determining the preferred thickness for the quantum-well layers. Embodiments of the present invention are described having at least one cladding layer to increase the optical and carrier confinement in the active region, and to provide for waveguiding of the light generated within the active region. Examples have been set forth showing embodiments of the present invention as surface- and edge-emitting light emitting diodes (LEDs), an optically-pumped semiconductor laser, and an electrically-injected semiconductor diode laser. The light emission from each of the infrared emitting devices of the present invention is in the midwave infrared region of the spectrum from about 2 to 6 microns.

  5. Destilaria Alpha | Open Energy Information

    Open Energy Info (EERE)

    Alpha Jump to: navigation, search Name: Destilaria Alpha Place: Claudio, Minas Gerais, Brazil Product: Brazil based ethanol producer. References: Destilaria Alpha1 This article...

  6. Blue light emitting thiogallate phosphor

    DOE Patents [OSTI]

    Dye, Robert C.; Smith, David C.; King, Christopher N.; Tuenge, Richard T.

    1998-01-01

    A crystalline blue emitting thiogallate phosphor of the formula RGa.sub.2 S.sub.4 :Ce.sub.x where R is selected from the group consisting of calcium, strontium, barium and zinc, and x is from about 1 to 10 atomic percent, the phosphor characterized as having a crystalline microstructure on the size order of from about 100 .ANG. to about 10,000 .ANG. is provided together with a process of preparing a crystalline blue emitting thiogallate phosphor by depositing on a substrate by CVD and resultant thin film electroluminescent devices including a layer of such deposited phosphor on an ordinary glass substrate.

  7. ISOTOPE SEPARATORS

    DOE Patents [OSTI]

    Bacon, C.G.

    1958-08-26

    An improvement is presented in the structure of an isotope separation apparatus and, in particular, is concerned with a magnetically operated shutter associated with a window which is provided for the purpose of enabling the operator to view the processes going on within the interior of the apparatus. The shutier is mounted to close under the force of gravity in the absence of any other force. By closing an electrical circuit to a coil mouated on the shutter the magnetic field of the isotope separating apparatus coacts with the magnetic field of the coil to force the shutter to the open position.

  8. I ISOTOPES

    Office of Legacy Management (LM)

    fl6-6 ' , WTELEEYNE I ISOTOPES i - ' 50<77 /,' y. 6 IWL-5025-473 SUBSURFACE URASIUM OJ: THE GROUNDS OF NL BEARINGS, ALBAh'Y Heyitt Iv. Jeter Douglas M. Eagleson Fred J. Frullo TELEDYNE ISOTOPES 50 VAK BUREN A\!EMJE WESTKOOD, NEK JERSEY 07675 7 Dcccmhcr 1953 Prepnrcd for NL f%carings/NL Tndustrics, Inc. 1130 CCVltrill AXr~lMIC Allmy, New York 12205 TABLE OF CONTEhTS 1.0 INTRODUCTION 2.0 METHODS 2.1 Soil Sampling 2.2 Sample Preparation 2.3 Analysis of Samples 3.0 RESULTS 4.0 SUMMARY REFERENCES

  9. Apparatus for detecting alpha radiation in difficult access areas

    DOE Patents [OSTI]

    Steadman, P.; MacArthur, D.W.

    1997-09-02

    An electrostatic alpha radiation detector for measuring alpha radiation emitted from inside an enclosure comprising an electrically conductive expandable electrode for insertion into the enclosure is disclosed. After insertion, the electrically conductive expandable electrode is insulated from the enclosure and defines a decay cavity between the electrically conductive expandable electrode and the enclosure so that air ions generated in the decay cavity are electrostatically captured by the electrically conductive expandable electrode and the enclosure when an electric potential is applied between the electrically conductive expandable electrode and the enclosure. Indicator means are attached to the electrically conductive expandable electrode for indicating an electrical current produced by generation of the air ions generated in the decay cavity by collisions between air molecules and the alpha particles emitted from the enclosure. A voltage source is connected between the indicator means and the electrically conductive enclosure for creating an electric field between the electrically conductive expandable electrode and the enclosure. 4 figs.

  10. Apparatus for detecting alpha radiation in difficult access areas

    DOE Patents [OSTI]

    Steadman, Peter; MacArthur, Duncan W.

    1997-09-02

    An electrostatic alpha radiation detector for measuring alpha radiation emitted from inside an enclosure comprising an electrically conductive expandable electrode for insertion into the enclosure. After insertion, the electrically conductive expandable electrode is insulated from the enclosure and defines a decay cavity between the electrically conductive expandable electrode and the enclosure so that air ions generated in the decay cavity are electrostatically captured by the electrically conductive expandable electrode and the enclosure when an electric potential is applied between the electrically conductive expandable electrode and the enclosure. Indicator means are attached to the electrically conductive expandable electrode for indicating an electrical current produced by generation of the air ions generated in the decay cavity by collisions between air molecules and the alpha particles emitted from the enclosure. A voltage source is connected between the indicator means and the electrically conductive enclosure for creating an electric field between the electrically conductive expandable electrode and the enclosure.

  11. Infrared emitting device and method

    DOE Patents [OSTI]

    Kurtz, S.R.; Biefeld, R.M.; Dawson, L.R.; Howard, A.J.; Baucom, K.C.

    1997-04-29

    The infrared emitting device comprises a III-V compound semiconductor substrate upon which are grown a quantum-well active region having a plurality of quantum-well layers formed of a ternary alloy comprising InAsSb sandwiched between barrier layers formed of a ternary alloy having a smaller lattice constant and a larger energy bandgap than the quantum-well layers. The quantum-well layers are preferably compressively strained to increase the threshold energy for Auger recombination; and a method is provided for determining the preferred thickness for the quantum-well layers. Embodiments of the present invention are described having at least one cladding layer to increase the optical and carrier confinement in the active region, and to provide for waveguiding of the light generated within the active region. Examples have been set forth showing embodiments of the present invention as surface- and edge-emitting light emitting diodes (LEDs), an optically-pumped semiconductor laser, and an electrically-injected semiconductor diode laser. The light emission from each of the infrared emitting devices of the present invention is in the midwave infrared region of the spectrum from about 2 to 6 microns. 8 figs.

  12. Broadband light-emitting diode

    DOE Patents [OSTI]

    Fritz, Ian J.; Klem, John F.; Hafich, Michael J.

    1998-01-01

    A broadband light-emitting diode. The broadband light-emitting diode (LED) comprises a plurality of III-V compound semiconductor layers grown on a semiconductor substrate, with the semiconductor layers including a pair of cladding layers sandwiched about a strained-quantum-well active region having a plurality of different energy bandgaps for generating light in a wavelength range of about 1.3-2 .mu.m. In one embodiment of the present invention, the active region may comprise a first-grown quantum-well layer and a last-grown quantum-well layer that are oppositely strained; whereas in another embodiment of the invention, the active region is formed from a short-period superlattice structure (i.e. a pseudo alloy) comprising alternating thin layers of InGaAs and InGaAlAs. The use a short-period superlattice structure for the active region allows different layers within the active region to be simply and accurately grown by repetitively opening and closing one or more shutters in an MBE growth apparatus to repetitively switch between different growth states therein. The broadband LED may be formed as either a surface-emitting LED or as an edge-emitting LED for use in applications such as chemical sensing, fiber optic gyroscopes, wavelength-division-multiplexed (WDM) fiber-optic data links, and WDM fiber-optic sensor networks for automobiles and aircraft.

  13. Broadband light-emitting diode

    DOE Patents [OSTI]

    Fritz, I.J.; Klem, J.F.; Hafich, M.J.

    1998-07-14

    A broadband light-emitting diode is disclosed. The broadband light-emitting diode (LED) comprises a plurality of III-V compound semiconductor layers grown on a semiconductor substrate, with the semiconductor layers including a pair of cladding layers sandwiched about a strained-quantum-well active region having a plurality of different energy bandgaps for generating light in a wavelength range of about 1.3--2 {micro}m. In one embodiment of the present invention, the active region may comprise a first-grown quantum-well layer and a last-grown quantum-well layer that are oppositely strained; whereas in another embodiment of the invention, the active region is formed from a short-period superlattice structure (i.e. a pseudo alloy) comprising alternating thin layers of InGaAs and InGaAlAs. The use a short-period superlattice structure for the active region allows different layers within the active region to be simply and accurately grown by repetitively opening and closing one or more shutters in an MBE growth apparatus to repetitively switch between different growth states therein. The broadband LED may be formed as either a surface-emitting LED or as an edge-emitting LED for use in applications such as chemical sensing, fiber optic gyroscopes, wavelength-divisionmultiplexed (WDM) fiber-optic data links, and WDM fiber-optic sensor networks for automobiles and aircraft. 10 figs.

  14. Quantum Dot Light Emitting Diode

    SciTech Connect (OSTI)

    Keith Kahen

    2008-07-31

    The project objective is to create low cost coatable inorganic light emitting diodes, composed of quantum dot emitters and inorganic nanoparticles, which have the potential for efficiencies equivalent to that of LEDs and OLEDs and lifetime, brightness, and environmental stability between that of LEDs and OLEDs. At the end of the project the Recipient shall gain an understanding of the device physics and properties of Quantum-Dot LEDs (QD-LEDs), have reliable and accurate nanocrystal synthesis routines, and have formed green-yellow emitting QD-LEDs with a device efficiency greater than 3 lumens/W, a brightness greater than 400 cd/m2, and a device operational lifetime of more than 1000 hours. Thus the aim of the project is to break the current cost-efficiency paradigm by creating novel low cost inorganic LEDs composed of inorganic nanoparticles.

  15. Quantum Dot Light Emitting Diode

    SciTech Connect (OSTI)

    Kahen, Keith

    2008-07-31

    The project objective is to create low cost coatable inorganic light emitting diodes, composed of quantum dot emitters and inorganic nanoparticles, which have the potential for efficiencies equivalent to that of LEDs and OLEDs and lifetime, brightness, and environmental stability between that of LEDs and OLEDs. At the end of the project the Recipient shall gain an understanding of the device physics and properties of Quantum-Dot LEDs (QD-LEDs), have reliable and accurate nanocrystal synthesis routines, and have formed green-yellow emitting QD-LEDs with a device efficiency greater than 3 lumens/W, a brightness greater than 400 cd/m{sup 2}, and a device operational lifetime of more than 1000 hours. Thus the aim of the project is to break the current cost-efficiency paradigm by creating novel low cost inorganic LEDs composed of inorganic nanoparticles.

  16. Porous light-emitting compositions

    DOE Patents [OSTI]

    Burrell, Anthony K.; McCleskey, Thomas Mark; Jia, Quanxi; Bauer, Eve; Mueller, Alexander H.

    2012-04-17

    Light-emitting devices are prepared by coating a porous substrate using a polymer-assisted deposition process. Solutions of metal precursor and soluble polymers having binding properties for metal precursor were coated onto porous substrates. The coated substrates were heated at high temperatures under a suitable atmosphere. The result was a substrate with a conformal coating that did not substantially block the pores of the substrate.

  17. White light-emitting organic electroluminescent devices

    DOE Patents [OSTI]

    Shiang, Joseph John; Duggal, Anil Raj; Parthasarathy, Gautam

    2006-06-20

    A light-emitting device comprises a light-emitting member, which comprises two electrodes, at least two organic electroluminescent ("EL") materials disposed between the electrodes, a charge blocking material disposed between the electrodes, and at least one photoluminescent ("PL") material. The light-emitting member emits electromagnetic ("EM") radiation having a first spectrum in response to a voltage applied across the two electrodes. The PL material absorbs a portion of the EM radiation emitted by the light-emitting member and emits EM radiation having second spectrum different than the first spectrum. Each of the organic EL materials emits EM radiation having a wavelength range selected from the group consisting of blue and red wavelength ranges.

  18. Visible light emitting vertical cavity surface emitting lasers

    DOE Patents [OSTI]

    Bryan, Robert P. (Boulder, CO); Olbright, Gregory R. (Boulder, CO); Lott, James A. (Albuquerque, NM); Schneider, Jr., Richard P. (Albuquerque, NM)

    1995-01-01

    A vertical cavity surface emitting laser that emits visible radiation is built upon a substrate, then having mirrors, the first mirror on top of the substrate; both sets of mirrors being a distributed Bragg reflector of either dielectrics or other materials which affect the resistivity or of semiconductors, such that the structure within the mirror comprises a plurality of sets, each having a thickness of .lambda./2n where n is the index of refraction of each of the sets; each of the mirrors adjacent to spacers which are on either side of an optically active bulk or quantum well layer; and the spacers and the optically active layer are from one of the following material systems: In.sub.z (Al.sub.y Ga.sub.1-y).sub.1-z P, InAlGaAs, AlGaAs, InGaAs, or AlGaP/GaP, wherein the optically active region having a length equal to m .lambda./2n.sub.eff where m is an integer and n.sub.eff is the effective index of refraction of the laser cavity, and the spacer layer and one of the mirrors being transmissive to radiation having a wavelength of .lambda./n, typically within the green to red portion of the visible spectrum.

  19. Visible light emitting vertical cavity surface emitting lasers

    DOE Patents [OSTI]

    Bryan, R.P.; Olbright, G.R.; Lott, J.A.; Schneider, R.P. Jr.

    1995-06-27

    A vertical cavity surface emitting laser that emits visible radiation is built upon a substrate, then having mirrors, the first mirror on top of the substrate; both sets of mirrors being a distributed Bragg reflector of either dielectrics or other materials which affect the resistivity or of semiconductors, such that the structure within the mirror comprises a plurality of sets, each having a thickness of {lambda}/2n where n is the index of refraction of each of the sets; each of the mirrors adjacent to spacers which are on either side of an optically active bulk or quantum well layer; and the spacers and the optically active layer are from one of the following material systems: In{sub z}(Al{sub y}Ga{sub 1{minus}y}){sub 1{minus}z}P, InAlGaAs, AlGaAs, InGaAs, or AlGaP/GaP, wherein the optically active region having a length equal to m {lambda}/2n{sub eff} where m is an integer and n{sub eff} is the effective index of refraction of the laser cavity, and the spacer layer and one of the mirrors being transmissive to radiation having a wavelength of {lambda}/n, typically within the green to red portion of the visible spectrum. 10 figs.

  20. Event counting alpha detector

    DOE Patents [OSTI]

    Bolton, R.D.; MacArthur, D.W.

    1996-08-27

    An electrostatic detector is disclosed for atmospheric radon or other weak sources of alpha radiation. In one embodiment, nested enclosures are insulated from one another, open at the top, and have a high voltage pin inside and insulated from the inside enclosure. An electric field is produced between the pin and the inside enclosure. Air ions produced by collision with alpha particles inside the decay volume defined by the inside enclosure are attracted to the pin and the inner enclosure. With low alpha concentrations, individual alpha events can be measured to indicate the presence of radon or other alpha radiation. In another embodiment, an electrical field is produced between parallel plates which are insulated from a single decay cavity enclosure. 6 figs.

  1. Event counting alpha detector

    DOE Patents [OSTI]

    Bolton, Richard D.; MacArthur, Duncan W.

    1996-01-01

    An electrostatic detector for atmospheric radon or other weak sources of alpha radiation. In one embodiment, nested enclosures are insulated from one another, open at the top, and have a high voltage pin inside and insulated from the inside enclosure. An electric field is produced between the pin and the inside enclosure. Air ions produced by collision with alpha particles inside the decay volume defined by the inside enclosure are attracted to the pin and the inner enclosure. With low alpha concentrations, individual alpha events can be measured to indicate the presence of radon or other alpha radiation. In another embodiment, an electrical field is produced between parallel plates which are insulated from a single decay cavity enclosure.

  2. Imaging alpha particle detector

    DOE Patents [OSTI]

    Anderson, David F.

    1985-01-01

    A method and apparatus for detecting and imaging alpha particles sources is described. A conducting coated high voltage electrode (1) and a tungsten wire grid (2) constitute a diode configuration discharge generator for electrons dislodged from atoms or molecules located in between these electrodes when struck by alpha particles from a source (3) to be quantitatively or qualitatively analyzed. A thin polyester film window (4) allows the alpha particles to pass into the gas enclosure and the combination of the glass electrode, grid and window is light transparent such that the details of the source which is imaged with high resolution and sensitivity by the sparks produced can be observed visually as well. The source can be viewed directly, electronically counted or integrated over time using photographic methods. A significant increase in sensitivity over other alpha particle detectors is observed, and the device has very low sensitivity to gamma or beta emissions which might otherwise appear as noise on the alpha particle signal.

  3. Imaging alpha particle detector

    DOE Patents [OSTI]

    Anderson, D.F.

    1980-10-29

    A method and apparatus for detecting and imaging alpha particles sources is described. A dielectric coated high voltage electrode and a tungsten wire grid constitute a diode configuration discharge generator for electrons dislodged from atoms or molecules located in between these electrodes when struck by alpha particles from a source to be quantitatively or qualitatively analyzed. A thin polyester film window allows the alpha particles to pass into the gas enclosure and the combination of the glass electrode, grid and window is light transparent such that the details of the source which is imaged with high resolution and sensitivity by the sparks produced can be observed visually as well. The source can be viewed directly, electronically counted or integrated over time using photographic methods. A significant increase in sensitivity over other alpha particle detectors is observed, and the device has very low sensitivity to gamma or beta emissions which might otherwise appear as noise on the alpha particle signal.

  4. Method for separating isotopes

    DOE Patents [OSTI]

    Jepson, B.E.

    1975-10-21

    Isotopes are separated by contacting a feed solution containing the isotopes with a cyclic polyether wherein a complex of one isotope is formed with the cyclic polyether, the cyclic polyether complex is extracted from the feed solution, and the isotope is thereafter separated from the cyclic polyether.

  5. Stable isotope studies

    SciTech Connect (OSTI)

    Ishida, T.

    1992-01-01

    The research has been in four general areas: (1) correlation of isotope effects with molecular forces and molecular structures, (2) correlation of zero-point energy and its isotope effects with molecular structure and molecular forces, (3) vapor pressure isotope effects, and (4) fractionation of stable isotopes. 73 refs, 38 figs, 29 tabs.

  6. {alpha} decay of {sup 180,181}Pb

    SciTech Connect (OSTI)

    Andreyev, A. N.; Antalic, S.; Saro, S.; Ackermann, D.; Comas, V. F.; Heinz, S.; Heredia, J. A.; Hessberger, F. P.; Khuyagbaatar, J.; Kojouharov, I.; Kindler, B.; Lommel, B.; Mann, R.; Cocolios, T. E.; Elseviers, J.; Huyse, M.; Duppen, P. Van; Venhart, M.; Franchoo, S.; Hofmann, S.

    2009-11-15

    A detailed {alpha}-decay study of the neutron-deficient isotope {sup 181}Pb has been performed in the complete fusion reaction {sup 40}Ca+{sup 144}Sm{yields}{sup 184}Pb* at the velocity filter SHIP (GSI, Darmstadt). In comparison with the literature, more precise data have been deduced for the I{sup {pi}}=(9/2{sup -}) ground state in this nucleus, which is presumably based on the neutron {nu}h{sub 9/2} spherical orbital. Improved {alpha}-decay data were also measured for {sup 180}Pb.

  7. Isotope separation by photochromatography

    DOE Patents [OSTI]

    Suslick, K.S.

    1975-10-03

    A photochromatographic method for isotope separation is described. An isotopically mixed molecular species is adsorbed on an adsorptive surface, and the adsorbed molecules are irradiated with radiation of a predetermined wavelength which will selectively excite desired isotopic species. Sufficient energy is transferred to the excited molecules to desorb them from the surface and thus separate them from the undesired isotopic species. The method is particularly applicable to the separation of hydrogen isotopes. (BLM)

  8. Isotope separation by photochromatography

    DOE Patents [OSTI]

    Suslick, Kenneth S.

    1977-01-01

    An isotope separation method which comprises physically adsorbing an isotopically mixed molecular species on an adsorptive surface and irradiating the adsorbed molecules with radiation of a predetermined wavelength which will selectively excite a desired isotopic species. Sufficient energy is transferred to the excited molecules to desorb them from the surface and thereby separate them from the unexcited undesired isotopic species. The method is particularly applicable to the separation of hydrogen isotopes.

  9. Green emitting phosphors and blends thereof

    DOE Patents [OSTI]

    Setlur, Anant Achyut; Siclovan, Oltea Puica; Nammalwar, Prasanth Kumar; Sathyanarayan, Ramesh Rao; Porob, Digamber G.; Chandran, Ramachandran Gopi; Heward, William Jordan; Radkov, Emil Vergilov; Briel, Linda Jane Valyou

    2010-12-28

    Phosphor compositions, blends thereof and light emitting devices including white light emitting LED based devices, and backlights, based on such phosphor compositions. The devices include a light source and a phosphor material as described. Also disclosed are phosphor blends including such a phosphor and devices made therefrom.

  10. Alpha detection in pipes using an inverting membrane scintillator

    SciTech Connect (OSTI)

    Kendrick, D.T.; Cremer, C.D.; Lowry, W.

    1995-10-01

    Characterization of surface alpha emitting contamination inside enclosed spaces such as piping systems presents an interesting radiological measurement challenge. Detection of these alpha particles from the exterior of the pipe is impossible since the alpha particles are completely absorbed by the pipe wall. Traditional survey techniques, using hand-held instruments, simply can not be used effectively inside pipes. Science and Engineering Associates, Inc. is currently developing an enhancement to its Pipe Explorer{trademark} system that will address this challenge. The Pipe Explorer{trademark} uses a unique sensor deployment method where an inverted tubular membrane is propagated through complex pipe runs via air pressure. The inversion process causes the membrane to fold out against the pipe wall, such that no part of the membrane drags along the pipe wall. This deployment methodology has been successfully demonstrated at several DOE sites to transport specially designed beta and gamma, scintillation detectors into pipes ranging in length up to 250 ft.

  11. Light emitting device having peripheral emissive region

    DOE Patents [OSTI]

    Forrest, Stephen R

    2013-05-28

    Light emitting devices are provided that include one or more OLEDs disposed only on a peripheral region of the substrate. An OLED may be disposed only on a peripheral region of a substantially transparent substrate and configured to emit light into the substrate. Another surface of the substrate may be roughened or include other features to outcouple light from the substrate. The edges of the substrate may be beveled and/or reflective. The area of the OLED(s) may be relatively small compared to the substrate surface area through which light is emitted from the device. One or more OLEDs also or alternatively may be disposed on an edge of the substrate about perpendicular to the surface of the substrate through which light is emitted, such that they emit light into the substrate. A mode expanding region may be included between each such OLED and the substrate.

  12. Organic light emitting devices for illumination

    DOE Patents [OSTI]

    Hack, Michael; Lu, Min-Hao Michael; Weaver, Michael S.

    2012-01-24

    An organic light emitting device an a method of obtaining illumination from such a device is provided. The device has a plurality of regions, each region having an organic emissive layer adapted to emit a different spectrum of light. The regions in combination emit light suitable for illumination purposes. The area of each region may be selected such that the device is more efficient than an otherwise equivalent device having regions of equal size. The regions may have an aspect ratio of at least about four. All parts of any given region may be driven at the same current.

  13. Organic light emitting devices for illumination

    DOE Patents [OSTI]

    Hack, Michael; Lu, Min-Hao Michael; Weaver, Michael S.

    2010-02-16

    An organic light emitting device is provided. The device has a plurality of regions, each region having an organic emissive layer adapted to emit a different spectrum of light. The regions in combination emit light suitable for illumination purposes. The area of each region may be selected such that the device is more efficient that an otherwise equivalent device having regions of equal size. The regions may have an aspect ratio of at least about four. All parts of any given region may be driven at the same current.

  14. Synthesis and characterization of lanthanum phosphate nanoparticles as carriers for 223Ra and 225Ra for targeted alpha therapy

    SciTech Connect (OSTI)

    Rojas Marin, Jessika V; Woodward, Jonathan; Chen, Nan; Rondinone, Adam Justin; Castano, Carlos H; Mirzadeh, Saed

    2015-01-01

    Introduction. Targeted alpha therapy (TAT) has the potential for killing specific tumor cells with minimum collateral damage to surrounding healthy tissue. Radionuclides such as 223Ra, 225Ra, and 225Ac are of special interest for radiotherapeutic applications as they emit multiple -particles during their decay. Utilizing appropriate carriers capable of retaining both the parent radioisotope as well as daughter products is important for the effective delivery of the radioisotope to the tumor site while mitigating global in vivo radiotoxicity. Methods. In this work, core and core+2 shells (NPs with 2 additional layers of cold LaPO4 deposited on the core surfaces) LaPO4 nanoparticles (NPs) were synthesized containing either 223Ra or 225Ra/225Ac and the retention of the parents and daughters within the NPs in vitro was investigated. Results. The NPs crystallized in rhabdophane phase with mean diameters of 3.4 and 6.3 nm for core and core+2 shells, respectively. The core LaPO 4 NPs retained up to 88% of 223Ra over 35 days. However, in the core+2 shell NPs, the retention of 223Ra and its daughter, 211Pb, was improved to > 99.9% over 27 days. Additionally, the retention of 225Ra/225Ac parents was > 99.98% and ~80% for the 221Fr and 213Bi daughters over 35 days for the core+2 shell NPs. Conclusions. These results suggest that LaPO4 NPs are potentially effective carriers of radium isotopes.

  15. Link Alpha K

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    k A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Key Plans: Building Floor Plans Key Request: Facilities Lock Shop

  16. Link Alpha U

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    u A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Unconscious Bias University/Hill Operations Center (Biosciences

  17. Link Alpha Y

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    y A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Year End Close

  18. Link Alpha Z

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    z A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Zimride Zip + 4 (Zip codes for Berkeley Lab)

  19. Link Alpha V

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    v A B C D E F G H I J K L M N O P Q R S T V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Vacation Policy Vanpool Commuting Program for Employees...

  20. Modeling of temporal behavior of isotopic exchange between gaseous hydrogen and palladium hydride power

    SciTech Connect (OSTI)

    Melius, C F; Foltz, G W

    1987-01-01

    A parametric rate-equation model is described which depicts the time dependent behavior of the isotopic exchange process occurring between the solid and gas phases in gaseous hydrogen (deuterium) flows through packed-powder palladium deuteride (hydride) beds. The exchange mechanism is assumed to be rate-limited by processes taking place on the surface of the powder. The fundamental kinetic parameter of the model is the isotopic exchange probability, p, which is the probability that an isotopic exchange event occurs during a collision of a gas phase atom with the surface. Isotope effects between the gas and solid phases are explicitly included in terms of the isotope separation factor, ..cap alpha... Results of the model are compared with recent experimental measurements of isotope exchange in the ..beta..-phase hydrogen/palladium system and, using a literature value of ..cap alpha.. = 2.4, a good description of the experimental data is obtained for p approx. 10/sup -7/. In view of the importance of the isotope effects in the hydrogen/palladium system and the range of ..cap alpha.. values reported for the ..beta..-phase in the literature, the sensitivity of the model results to a variation in the value of ..cap alpha.. is examined.

  1. Manus Water Isotope Investigation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    9 Manus Water Isotope Investigation Field Campaign Report JL Conroy D Noone KM Cobb March ... DOESC-ARM-15-079 Manus Water Isotope Investigation Field Campaign Report JL Conroy, ...

  2. Manus Water Isotope Investigation

    Office of Scientific and Technical Information (OSTI)

    ENERGY Office of Science DOESC-ARM-15-079 Manus Water Isotope Investigation Field ... DOESC-ARM-15-079 Manus Water Isotope Investigation Field Campaign Report JL Conroy, ...

  3. Stable blue phosphorescent organic light emitting devices

    DOE Patents [OSTI]

    Forrest, Stephen R.; Thompson, Mark; Giebink, Noel

    2014-08-26

    Novel combination of materials and device architectures for organic light emitting devices is provided. An organic light emitting device, is provided, having an anode, a cathode, and an emissive layer disposed between the anode and the cathode. The emissive layer includes a host and a phosphorescent emissive dopant having a peak emissive wavelength less than 500 nm, and a radiative phosphorescent lifetime less than 1 microsecond. Preferably, the phosphorescent emissive dopant includes a ligand having a carbazole group.

  4. Demonstration Assessment of Light-Emitting Diode (LED) Freezer...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Demonstration Assessment of Light-Emitting Diode (LED) Freezer Case Lighting Demonstration Assessment of Light-Emitting Diode (LED) Freezer Case Lighting This document is a report ...

  5. Studies of isotopic exchange between gaseous hydrogen and palladium hydride powder

    SciTech Connect (OSTI)

    Foltz, G.W.; Melius, C.F.

    1987-12-01

    A gas flow apparatus has been constructed and used to study the isotopic exchange reaction occurring between the solid and gas phases in hydrogen (deuterium) gas flows directed through packed-powder beds of ..beta..-phase palladium deuteride (hydride). Spontaneous Raman light scattering is employed to obtain a real-time analysis of the isotopic composition of the gas (H/sub 2/, D/sub 2/, HD) exiting from the bed. A parametric rate-equation model is described which depicts the time-dependent behavior of the isotopic exchange process. The exchange mechanism is assumed to be rate-limited by processes occurring on the surface of the powder. The fundamental kinetic parameter of the model is the isotopic exchange probability, p, which is the probability that an isotopic exchange event occurs during a collision of a gas-phase atom with the surface. Isotope effects between the gas and solid phases are explicitly included in terms of the isotope separation factor, ..cap alpha... Results of the model are compared with the experimental measurements and, using a literature value of ..cap alpha.. = 2.4, good agreement is obtained for p approx. = 10/sup -7/. In view of the importance of the isotope effects in the hydrogen/palladium system and the range of a values reported for the ..beta..-phase in the literature, the sensitivity of the model results to a variation in the value of ..cap alpha.. is examined.

  6. Generation of Radixenon Isotopes

    SciTech Connect (OSTI)

    McIntyre, Justin I.; Bowyer, Ted W.; Hayes, James C.; Heimbigner, Tom R.; Morris, Scott J.; Panisko, Mark E.; Pitts, W. K.; Pratt, Sharon L.; Reeder, Paul L.; Thomas, Charles W.

    2003-06-30

    Pacific Northwest National Laboratory has developed an automated system for separating Xe from air and can detect the following radioxenon isotopes, 131mXe, 133mXe, 133Xe, and 135Xe. This report details the techniques used to generate the various radioxenon isotopes that are used for the calibration of the detector as well as other isotopes that have the potential to interfere with the fission produced radioxenon isotopes. Fission production is covered first using highly enriched uranium followed by a description and results from an experiment to produce radioxenon isotopes from neutron activation of ambient xenon.

  7. ISOTOPE CONVERSION DEVICE

    DOE Patents [OSTI]

    Wigner, E.P.; Young, G.J.; Ohlinger, L.A.

    1957-12-01

    This patent relates to nuclear reactors of tbe type utilizing a liquid fuel and designed to convert a non-thermally fissionable isotope to a thermally fissionable isotope by neutron absorption. A tank containing a reactive composition of a thermally fissionable isotope dispersed in a liquid moderator is disposed within an outer tank containing a slurry of a non-thermally fissionable isotope convertible to a thermally fissionable isotope by neutron absorption. A control rod is used to control the chain reaction in the reactive composition and means are provided for circulating and cooling the reactive composition and slurry in separate circuits.

  8. Link Alpha Q

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    q A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Qualified Electrical Worker (QEW) Qualified Electrical Worker (QEW) Support Quality Assurance Quickbase (Electrical Safety Database)

  9. Side-emitting fiber optic position sensor

    DOE Patents [OSTI]

    Weiss, Jonathan D.

    2008-02-12

    A side-emitting fiber optic position sensor and method of determining an unknown position of an object by using the sensor. In one embodiment, a concentrated beam of light source illuminates the side of a side-emitting fiber optic at an unknown axial position along the fiber's length. Some of this side-illuminated light is in-scattered into the fiber and captured. As the captured light is guided down the fiber, its intensity decreases due to loss from side-emission away from the fiber and from bulk absorption within the fiber. By measuring the intensity of light emitted from one (or both) ends of the fiber with a photodetector(s), the axial position of the light source is determined by comparing the photodetector's signal to a calibrated response curve, look-up table, or by using a mathematical model. Alternatively, the side-emitting fiber is illuminated at one end, while a photodetector measures the intensity of light emitted from the side of the fiber, at an unknown position. As the photodetector moves further away from the illuminated end, the detector's signal strength decreases due to loss from side-emission and/or bulk absorption. As before, the detector's signal is correlated to a unique position along the fiber.

  10. SOURCES 4C : a code for calculating ([alpha],n), spontaneous fission, and delayed neutron sources and spectra.

    SciTech Connect (OSTI)

    Wilson, W. B.; Perry, R. T.; Shores, E. F.; Charlton, W. S.; Parish, Theodore A.; Estes, G. P.; Brown, T. H.; Arthur, Edward D. ,; Bozoian, Michael; England, T. R.; Madland, D. G.; Stewart, J. E.

    2002-01-01

    SOURCES 4C is a computer code that determines neutron production rates and spectra from ({alpha},n) reactions, spontaneous fission, and delayed neutron emission due to radionuclide decay. The code is capable of calculating ({alpha},n) source rates and spectra in four types of problems: homogeneous media (i.e., an intimate mixture of a-emitting source material and low-Z target material), two-region interface problems (i.e., a slab of {alpha}-emitting source material in contact with a slab of low-Z target material), three-region interface problems (i.e., a thin slab of low-Z target material sandwiched between {alpha}-emitting source material and low-Z target material), and ({alpha},n) reactions induced by a monoenergetic beam of {alpha}-particles incident on a slab of target material. Spontaneous fission spectra are calculated with evaluated half-life, spontaneous fission branching, and Watt spectrum parameters for 44 actinides. The ({alpha},n) spectra are calculated using an assumed isotropic angular distribution in the center-of-mass system with a library of 107 nuclide decay {alpha}-particle spectra, 24 sets of measured and/or evaluated ({alpha},n) cross sections and product nuclide level branching fractions, and functional {alpha}-particle stopping cross sections for Z < 106. The delayed neutron spectra are taken from an evaluated library of 105 precursors. The code provides the magnitude and spectra, if desired, of the resultant neutron source in addition to an analysis of the'contributions by each nuclide in the problem. LASTCALL, a graphical user interface, is included in the code package.

  11. Regioselective synthesis using the deuterium isotope effect

    SciTech Connect (OSTI)

    Miyano, M.

    1981-04-24

    Dehydration of 1a by various procedures invariably produced more exo olefin 2a than endo olefin 3a. This could be reversed by introduction of deuterium in the Me-21 group of the starting material. Thus, dehydration of 1b could afford more endo olefin 3b than exo olefin 2b due to the deuterium isotope effect. A regioselective synthesis of 18-oxoprogesterone (15a) from 3..beta..-hydroxypregn-5-en-20-one (5a) was carried out taking advantage of the deuterium isotope effect as depicted in Scheme I. The key steps were dehydration of 7b to predominantly endo olefin 9b and removal of the deuteriums from 18-oxoprogesterone-17..cap alpha..,21,21,21-d/sub 4/ (15b) to give 15a.

  12. Visible light surface emitting semiconductor laser

    DOE Patents [OSTI]

    Olbright, Gregory R.; Jewell, Jack L.

    1993-01-01

    A vertical-cavity surface-emitting laser is disclosed comprising a laser cavity sandwiched between two distributed Bragg reflectors. The laser cavity comprises a pair of spacer layers surrounding one or more active, optically emitting quantum-well layers having a bandgap in the visible which serve as the active optically emitting material of the device. The thickness of the laser cavity is m .lambda./2n.sub.eff where m is an integer, .lambda. is the free-space wavelength of the laser radiation and n.sub.eff is the effective index of refraction of the cavity. Electrical pumping of the laser is achieved by heavily doping the bottom mirror and substrate to one conductivity-type and heavily doping regions of the upper mirror with the opposite conductivity type to form a diode structure and applying a suitable voltage to the diode structure. Specific embodiments of the invention for generating red, green, and blue radiation are described.

  13. Link Alpha A

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    a A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z ABPDU (Advanced Biofuels Process Demonstration Unit) Accelerator Technology and Applied Physics Division (ATAP) Accident Report (Motor Vehicle) Accident Statistics Accident Statistics Archive Accommodations: Motels, Hotels and Housing for Visitors and Guests Accounts (new computer accounts) Accounts Payable (Disbursements)(processes payments and maintains records) Activity

  14. Link Alpha B

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    b A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Back-Up Dependent (Child & Elder) Care Program Backups for Computers Backups for PC and Mac (self-service using Carbonite) Badge Office BASE (Berkeley Accelerator Space Effects) BELLA (Berkeley Lab Laser Accelerator) Benefits Berkeley Center for Structural Biology(BCSB) Berkeley Lab 75th Anniversary Site Berkeley Lab Energy and Environmental Research Blog Berkeley Lab

  15. Link Alpha C

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    c A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Cafeteria: Laboratory Cafeteria menu Calendar Calendar of Events Calendaring FAQ Cancer & Carcinogens: Carcinogenic Potency Database Project Carbon Cycle 2.0 Careers Carpooling Catalog: Berkeley Lab Scientific and Technical Reports Catalog (1989 to present) Catastrophic Leave Sharing Catering CATS (Corrective Action Tracking System) CCSE: Center for Computational Sciences

  16. Link Alpha E

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    e A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Early Career Research Program Earth And Environmental Sciences Area eBuy (Firefox Recommended Browser) Ecology Department (EESA) Economic Impact Study ECR Ion Sources Educational Programs at the Lab EH&S Safety Training Electric Vehicle Charging Electrical Equipment Safety Program (EESP) Electrical Safety Manual Electrical Safety Program (PUB-3000 Chapter 8) Electrical

  17. Link Alpha F

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    f A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Facilities Division Facilities Lockshop Facilities Project Status Facilities Safety and Hazardous Waste Facilities Work Request Center Family Member Eligibility Verification Project FAQ on Computing Topics Financial Compliance Financial Management System (FMS 8.8 - FY14 and Prior) Financial Management System (FMS 9.2 - FY15+) Financial Management System (FMS) Help &

  18. Link Alpha G

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    g A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Gate Pass and Visitor Request Form (accessible only from onsite hosts) visitorpass.lbl.gov Gcal (Google Calendar) Gender Transition Guidelines, Workplace General Accounting Genome: DOE Joint Genome Institute Genomics: Visualization Tool for Alignments (VISTA) Geochemistry Department (EESA) Geophysics Department (EESA) GERT - General Employee Radiological Training (English)

  19. Link Alpha H

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    h A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Hands-on Universe (HOU) Program Harassment Prevention and Harassment Complaint Process HARP Hazard Management System (HMS) Hazardous Waste Requisition Health Services at the Lab (or call x6266) Heat Island Research Group Helios - harnessing the sun for a secure, sustainable, and prosperous future Help Desk (or call x4357) High Performance Computing Research Department Hire

  20. Link Alpha I

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    i A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Image Library Project Images - Release for Non-commercial Use Imaging and Distributed Computing Group (Home of the Whole Frog Project) Immigration Services Implicit Bias Improper Governmental Activities Reporting Incident Notification/Contact x6999 Indoor Air Quality Scientific Findings Resource Bank Indoor Air Quality, Inside Information Industrial Energy Analysis Industry

  1. Link Alpha J

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    j A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z JBEI: Joint BioEnergy Institute JCAP: Joint Center for Artificial Photosynthesis JDEM: The Joint Dark Energy Mission JGI: Joint Genome Institute Job Descriptions Job Hazards Analysis (JHA Help Center) Job Hazards Analysis (JHA Login page) Job Opening Request Jobs

  2. Link Alpha L

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    l A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z LabAlert - LabAlert Emergency Alerting Service Laboratory Counsel Laboratory Directed Research & Development Program (LDRD) Laboratory Property Review (LPR) Laboratory Support Services Lactation / Nursing Moms Lactation Accommodation Program Laser Ablation: Advanced Laser Technologies Lab Laser Management System (Laser Inventory) Laser Safety Web Page Lasers, Optical

  3. Link Alpha M

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    m A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Macintosh User Group (LBNL-MUG) Mail Services (Facilities Dep't.) Malware/Virus Protection and Prevention Mammary: Human Mammary Epithelial Cell (HMEC) Map: Berkeley Lab Global Talent Map Map: Lab Shuttle Bus Map Maps: Berkeley Lab Interactive Site Map Maps: Berkeley Lab Printable Site Map Massage Material Safety Data Sheets (Safety Data Sheets, SDS) Material Transfer

  4. Link Alpha N

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    n A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z National Health Survey NERSC: National Energy Research Scientific Computing Center Network Research Group New Employee Briefing New Employee Orientation & Training New Hire Request News Center News Releases: Subscribe to Lab News Email list Nobel Laureates Nondisclosure Agreements Notaries Public Nuclear Science Division (NSD) Nuclear Science: Relativistic Nuclear

  5. Link Alpha O

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    o A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Occurrence Reporting Off-site Storage Office of Contractor Assurance (OCA) Office of Institutional Assurance and Integrity (OIAI) Office of Planning and Strategic Development Office of Sponsored Projects and Industry Partnerships (OSPIP) - see OSPIP / IPO / OCFO Transition Office of the Chief Financial Officer (OCFO) Ombudsman - Technology Transfer / Innovation and

  6. Link Alpha R

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    r A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Radiation Protection Group (EH&S) Radiation Safety Committee Charter Radiation Safety Committee Members Receiving Recovery Act (American Recovery and Reinvestment Act) Recruitment Recycling (Waste Minimization) Reflective X-Ray Optics Renewable Energy Report Coordination Report Submission and Search Reporting Portal (Cognos) (FY15+) Reporting Portal (Cognos) Help &

  7. Link Alpha S

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    s A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Safety Advisory Committee Safety and Hazardous Waste (Facilities Division) Safety Awards Safety Concerns Safety Culture Improvement Safety Data Sheets (SDS) Safety Walkthrough Management Salary Ranges Salvage (Waste Minimization) Scientific Cluster Support Scientific Networking Division Scientific Programs Seaborg: Glenn Seaborg's Life & Contributions Search lab-wide web

  8. Link Alpha T

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    t A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Tax Services Technical Area Designation Technology Transfer Department (Innovation and Partnerships Office) Technology Transfer Ombudsman Telecommuting Telemetry Database Telephone Service Center Termination Termination Notification System (TNS) Today at Berkeley Lab Tours of Berkeley Lab for the Public Traffic Safety Training (Berkeley Lab Training) Transit Passes

  9. Link Alpha W

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    w A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z WageWorks Commuter Benefits for Lab Employees Walkthrough (Safety Management) Warehouse: see Off-site Storage Waste (Recycling and Composting) Waste Guide Waste Management Waste Minimization (Hazardous Waste) Weather Conditions at LBNL Web Job Order (WJO) Whistleblower Online Reporting Whistleblower Policy Windchill (Windchill Account Required, contact cad@lbl.gov) Windows

  10. Surface alpha clustering

    SciTech Connect (OSTI)

    Rotter, I.

    1983-05-01

    The problem of alpha decay is discussed on the basis of a theory which describes discrete and continuous states in a unified manner. A formula for numerical calculations is given in which configurational mixing as well as channel coupling is taken into account. The R-matrix approximation is shown to be justified if the width is spread over a small number of decay channels. Generally, renormalization of the wave function is necessary if a factorization of the width is assumed. The importance of channel coupling for the case of a small reduced width is discussed.

  11. HYDROGEN ISOTOPE TARGETS

    DOE Patents [OSTI]

    Ashley, R.W.

    1958-08-12

    The design of targets for use in the investigation of nuclear reactions of hydrogen isotopes by bombardment with accelerated particles is described. The target con struction eomprises a backing disc of a metal selected from the group consisting of molybdenunn and tungsten, a eoating of condensed titaniunn on the dise, and a hydrogen isotope selected from the group consisting of deuterium and tritium absorbed in the coatiag. The proeess for preparing these hydrogen isotope targets is described.

  12. Uranium Isotopic Assay Instrument

    SciTech Connect (OSTI)

    Anheier, Norman C.; Wojcik, Michael D.; Bushaw, Bruce A.

    2006-12-01

    The isotopic assay instrument under development at Pacific Northwest National Laboratory (PNNL) is capable of rapid prescreening to detect small and rare particles containing high concentrations of uranium in a heterogeneous sample. The isotopic measurement concept is based on laser vaporization of solid samples followed with sensitive isotope specific detection using either uranium atomic fluorescence emission or uranium atomic absorbance. Both isotopes are measured concurrently, following a single ablation laser pulse, using two external-cavity violet diode lasers. The simultaneous measurement of both isotopes enables the correlation of the fluorescence and absorbance signals on a shot-to-shot basis. This measurement approach demonstrated negligible channel crosstalk between isotopes. Rapid sample scanning provides high spatial resolution isotopic fluorescence and absorbance sample imagery of heterogeneous samples. Laser ablation combined with measurements of laser-induced fluorescence (LALIF) and through-plume laser absorbance (LAPLA) was applied to measure gadolinium isotope ratios in solid samples. Gadolinium has excitation wavelengths very close to the transitions of interest in uranium. Gadolinium has seven stable isotopes, and the natural 152Gd:160Gd ratio of 0.009 is in the range of what will be encountered for 235U:238U isotopic ratios. LAPLA measurements were demonstrated clearly using 152Gd (0.2% isotopic abundance) with a good signal-to-noise ratio. The ability to measure gadolinium abundances at this level indicates that measurements of 235U/238U isotopic ratios for natural (0.72%), depleted (0.25%), and low enriched uranium samples will be feasible.

  13. ARM - Measurement - Isotope ratio

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    govMeasurementsIsotope ratio ARM Data Discovery Browse Data Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Measurement : Isotope ratio Ratio of stable isotope concentrations. Categories Atmospheric State, Atmospheric Carbon Instruments The above measurement is considered scientifically relevant for the following instruments. Refer to the datastream (netcdf) file headers of each instrument for a list of all available measurements, including those

  14. Hybrid isotope separation scheme

    DOE Patents [OSTI]

    Maya, J.

    1991-06-18

    A method is described for yielding selectively a desired enrichment in a specific isotope including the steps of inputting into a spinning chamber a gas from which a scavenger, radiating the gas with a wave length or frequency characteristic of the absorption of a particular isotope of the atomic or molecular gas, thereby inducing a photochemical reaction between the scavenger, and collecting the specific isotope-containing chemical by using a recombination surface or by a scooping apparatus. 2 figures.

  15. Hybrid isotope separation scheme

    DOE Patents [OSTI]

    Maya, Jakob

    1991-01-01

    A method of yielding selectively a desired enrichment in a specific isotope including the steps of inputting into a spinning chamber a gas from which a scavenger, radiating the gas with a wave length or frequency characteristic of the absorption of a particular isotope of the atomic or molecular gas, thereby inducing a photochemical reaction between the scavenger, and collecting the specific isotope-containing chemical by using a recombination surface or by a scooping apparatus.

  16. Stable isotope enrichment

    ScienceCinema (OSTI)

    Egle, Brian

    2014-07-15

    Brian Egle is working to increase the nation's capacity to produce stable isotopes for use including medicine, industry and national security.

  17. Stable isotope enrichment

    SciTech Connect (OSTI)

    Egle, Brian

    2014-07-14

    Brian Egle is working to increase the nation's capacity to produce stable isotopes for use including medicine, industry and national security.

  18. PRINCIPAL ISOTOPE SELECTION REPORT

    SciTech Connect (OSTI)

    K. D. Wright

    1998-08-28

    Utilizing nuclear fuel to produce power in commercial reactors results in the production of hundreds of fission product and transuranic isotopes in the spent nuclear fuel (SNF). When the SNF is disposed of in a repository, the criticality analyses could consider all of the isotopes, some principal isotopes affecting criticality, or none of the isotopes, other than the initial loading. The selected set of principal isotopes will be the ones used in criticality analyses of the SNF to evaluate the reactivity of the fuel/waste package composition and configuration. This technical document discusses the process used to select the principal isotopes and the possible affect that these isotopes could have on criticality in the SNF. The objective of this technical document is to discuss the process used to select the principal isotopes for disposal criticality evaluations with commercial SNF. The principal isotopes will be used as supporting information in the ''Disposal Criticality Analysis Methodology Topical Report'' which will be presented to the United States Nuclear Regulatory Commission (NRC) when approved by the United States Department of Energy (DOE) Office of Civilian Radioactive Waste Management (OCRWM).

  19. Long range alpha particle detector

    DOE Patents [OSTI]

    MacArthur, D.W.; Wolf, M.A.; McAtee, J.L.; Unruh, W.P.; Cucchiara, A.L.; Huchton, R.L.

    1993-02-02

    An alpha particle detector capable of detecting alpha radiation from distant sources. In one embodiment, a high voltage is generated in a first electrically conductive mesh while a fan draws air containing air molecules ionized by alpha particles through an air passage and across a second electrically conductive mesh. The current in the second electrically conductive mesh can be detected and used for measurement or alarm. The detector can be used for area, personnel and equipment monitoring.

  20. Long range alpha particle detector

    DOE Patents [OSTI]

    MacArthur, Duncan W.; Wolf, Michael A.; McAtee, James L.; Unruh, Wesley P.; Cucchiara, Alfred L.; Huchton, Roger L.

    1993-01-01

    An alpha particle detector capable of detecting alpha radiation from distant sources. In one embodiment, a high voltage is generated in a first electrically conductive mesh while a fan draws air containing air molecules ionized by alpha particles through an air passage and across a second electrically conductive mesh. The current in the second electrically conductive mesh can be detected and used for measurement or alarm. The detector can be used for area, personnel and equipment monitoring.

  1. Price Quotes and Isotope Ordering

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Ordering Price Quotes and Isotope Ordering Isotopes produced at Los Alamos National Laboratory are saving lives, advancing cutting-edge research and keeping the U.S. safe. Isotope...

  2. Estimation of the time scale of last chance alpha emission using an atomic clock''

    SciTech Connect (OSTI)

    Gallamore, L.; Sarantites, D.G.; Charity, R.J.; Nicolis, N.G.; Sobotka, L.G. ); Beene, J.R.; Halbert, M.L.; Varner, R.L. )

    1994-02-01

    The probability of filling a [ital K]-vacancy, created on the incoming part of the collision, before [alpha]-particle emission is used to time the decay of Yb compound nuclei. These nuclei were produced in the fusion reaction 250 MeV [sup 60]Ni+[sup 100]Mo. In general the nuclear decays are too fast to be timed by this clock, however, [alpha]-particle emitting compound nucleus states have lifetimes sufficiently long for this technique to work when both the [alpha]-particle has low energy and the compound nucleus spin is large. This supports the existence of last, or near last, chance [alpha]-particle emission in the deexcitation of high spin compound nuclei.

  3. Link Alpha D

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    d A B C D E F G H I J K L M N O P Q R S T U V W Y Z Filter by alpha... A B C D E F G H I J K L M N O P Q R S T U V W Y Z Data Center Energy Management Data Management Research and Development Group Data Science and Technology Department Daughters and Sons to Work Day at the Lab Daylighting the New York Times Headquarters Building DC Power for Data Centers of the Future Demand Response Research Center Dental Plans: Phone & Contact Info for UC Dental Plans Directions on How to Get to the Lab

  4. Photochemical isotope separation

    DOE Patents [OSTI]

    Robinson, C.P.; Jensen, R.J.; Cotter, T.P.; Greiner, N.R.; Boyer, K.

    1987-04-28

    A process is described for separating isotopes by selective excitation of isotopic species of a volatile compound by tuned laser light. A highly cooled gas of the volatile compound is produced in which the isotopic shift is sharpened and defined. Before substantial condensation occurs, the cooled gas is irradiated with laser light precisely tuned to a desired wavelength to selectively excite a particular isotopic species in the cooled gas. The laser light may impart sufficient energy to the excited species to cause it to undergo photochemical reaction or even to photoionize. Alternatively, a two-photon irradiation may be applied to the cooled gas to induce photochemical reaction or photoionization. The process is particularly applicable to the separation of isotopes of uranium and plutonium. 8 figs.

  5. Laser isotope separation

    DOE Patents [OSTI]

    Robinson, C. Paul; Jensen, Reed J.; Cotter, Theodore P.; Boyer, Keith; Greiner, Norman R.

    1988-01-01

    A process and apparatus for separating isotopes by selective excitation of isotopic species of a volatile compound by tuned laser light. A highly cooled gas of the volatile compound is produced in which the isotopic shift is sharpened and defined. Before substantial condensation occurs, the cooled gas is irradiated with laser light precisely tuned to a desired wavelength to selectively excite a particular isotopic species in the cooled gas. The laser light may impart sufficient energy to the excited species to cause it to undergo photolysis, photochemical reaction or even to photoionize. Alternatively, a two-photon irradiation may be applied to the cooled gas to induce photolysis, photochemical reaction or photoionization. The process is particularly applicable to the separation of isotopes of uranium.

  6. Photochemical isotope separation

    DOE Patents [OSTI]

    Robinson, C. Paul; Jensen, Reed J.; Cotter, Theodore P.; Greiner, Norman R.; Boyer, Keith

    1987-01-01

    A process for separating isotopes by selective excitation of isotopic species of a volatile compound by tuned laser light. A highly cooled gas of the volatile compound is produced in which the isotopic shift is sharpened and defined. Before substantial condensation occurs, the cooled gas is irradiated with laser light precisely tuned to a desired wavelength to selectively excite a particular isotopic species in the cooled gas. The laser light may impart sufficient energy to the excited species to cause it to undergo photochemical reaction or even to photoionize. Alternatively, a two-photon irradiation may be applied to the cooled gas to induce photochemical reaction or photoionization. The process is particularly applicable to the separation of isotopes of uranium and plutonium.

  7. Laser isotope separation

    DOE Patents [OSTI]

    Robinson, C.P.; Reed, J.J.; Cotter, T.P.; Boyer, K.; Greiner, N.R.

    1975-11-26

    A process and apparatus for separating isotopes by selective excitation of isotopic species of a volatile compound by tuned laser light is described. A highly cooled gas of the volatile compound is produced in which the isotopic shift is sharpened and defined. Before substantial condensation occurs, the cooled gas is irradiated with laser light precisely tuned to a desired wavelength to selectively excite a particular isotopic species in the cooled gas. The laser light may impart sufficient energy to the excited species to cause it to undergo photolysis, photochemical reaction or even to photoionize. Alternatively, a two-photon irradiation may be applied to the cooled gas to induce photolysis, photochemical reaction or photoionization. The process is particularly applicable to the separation of isotopes of uranium.

  8. Gamma-Ray Library and Uncertainty Analysis: Passively Emitted Gamma Rays Used in Safeguards Technology

    SciTech Connect (OSTI)

    Parker, W

    2009-09-18

    Non-destructive gamma-ray analysis is a fundamental part of nuclear safeguards, including nuclear energy safeguards technology. Developing safeguards capabilities for nuclear energy will certainly benefit from the advanced use of gamma-ray spectroscopy as well as the ability to model various reactor scenarios. There is currently a wide variety of nuclear data that could be used in computer modeling and gamma-ray spectroscopy analysis. The data can be discrepant (with varying uncertainties), and it may difficult for a modeler or software developer to determine the best nuclear data set for a particular situation. To use gamma-ray spectroscopy to determine the relative isotopic composition of nuclear materials, the gamma-ray energies and the branching ratios or intensities of the gamma-rays emitted from the nuclides in the material must be well known. A variety of computer simulation codes will be used during the development of the nuclear energy safeguards, and, to compare the results of various codes, it will be essential to have all the {gamma}-ray libraries agree. Assessing our nuclear data needs allows us to create a prioritized list of desired measurements, and provides uncertainties for energies and especially for branching intensities. Of interest are actinides, fission products, and activation products, and most particularly mixtures of all of these radioactive isotopes, including mixtures of actinides and other products. Recent work includes the development of new detectors with increased energy resolution, and studies of gamma-rays and their lines used in simulation codes. Because new detectors are being developed, there is an increased need for well known nuclear data for radioactive isotopes of some elements. Safeguards technology should take advantage of all types of gamma-ray detectors, including new super cooled detectors, germanium detectors and cadmium zinc telluride detectors. Mixed isotopes, particularly mixed actinides found in nuclear reactor

  9. Method of making organic light emitting devices

    DOE Patents [OSTI]

    Shiang, Joseph John; Janora, Kevin Henry; Parthasarathy, Gautam; Cella, James Anthony; Chichak, Kelly Scott

    2011-03-22

    The present invention provides a method for the preparation of organic light-emitting devices comprising a bilayer structure made by forming a first film layer comprising an electroactive material and an INP precursor material, and exposing the first film layer to a radiation source under an inert atmosphere to generate an interpenetrating network polymer composition comprising the electroactive material. At least one additional layer is disposed on the reacted first film layer to complete the bilayer structure. The bilayer structure is comprised within an organic light-emitting device comprising standard features such as electrodes and optionally one or more additional layers serving as a bipolar emission layer, a hole injection layer, an electron injection layer, an electron transport layer, a hole transport layer, exciton-hole transporting layer, exciton-electron transporting layer, a hole transporting emission layer, or an electron transporting emission layer.

  10. Science on Tap - Isotopes

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Science on Tap - Isotopes Science on Tap - Isotopes WHEN: Jun 16, 2016 5:30 PM - 7:00 PM WHERE: UnQuarked Wine Room 145 Central Park Square, Los Alamos, New Mexico 87544 USA CONTACT: Linda Anderman (505) 665-9196 CATEGORY: Bradbury INTERNAL: Calendar Login Event Description Short presentation followed by lively interaction on the topic at hand. While isotopes are chemical elements (think periodic table), their varying numbers of neutrons mean they can be used in lots of different way. Join us

  11. Oxycarbonitride phosphors and light emitting devices using the same

    DOE Patents [OSTI]

    Li, Yuanqiang; Romanelli, Michael D.; Tian, Yongchi

    2015-12-22

    A family of oxycarbonitride phosphor compositions is provided. Also provided are light emitting devices incorporating the oxycarbonitride phosphor compositions.

  12. Atomic vapor laser isotope separation

    SciTech Connect (OSTI)

    Stern, R.C.; Paisner, J.A.

    1986-08-15

    The atomic vapor laser isotope separation (AVLIS) process for the enrichment of uranium is evaluated. (AIP)

  13. Plasma isotope separation methods

    SciTech Connect (OSTI)

    Grossman, M.W. ); Shepp, T.A. )

    1991-12-01

    Isotope separation has many important industrial, medical, and research applications. Large-scale processes have typically utilized complex cascade systems; for example, the gas centrifuge. Alternatively, high single-stage enrichment processes (as in the case of the calutron) are very energy intensive. Plasma-based methods being developed for the past 15 to 20 years have attempted to overcome these two drawbacks. In this review, six major types of isotope separation methods which involve plasma phenomena are discussed. These methods are: plasma centrifuge, AVLIS (atomic vapor laser isotope separation), ion wave, ICR (ion-cyclotron resonance), calutron, and gas discharge. The emphasis of this paper is to describe the plasma phenomena in these major categories. An attempt was made to include enough references so that more detailed study or evaluation of a particular method could readily be pursued. A brief discussion of isotope separation using mass balance concepts is also carried out.

  14. Synthesis and characterization of lanthanum phosphate nanoparticles as carriers for 223Ra and 225Ra for targeted alpha therapy

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Rojas, J. V.; Woodward, J. D.; Chen, N.; Rondinone, A. J.; Castano, C. H.; Mirzadeh, S.

    2015-03-19

    Targeted alpha therapy (TAT) has the potential for killing specific tumor cells with minimum collateral damage to surrounding healthy tissue. Radionuclides such as 223Ra, 225Ra, and 225Ac are of special interest for radiotherapeutic applications as they emit multiple -particles during their decay. Utilizing appropriate carriers capable of retaining both the parent radioisotope as well as daughter products is important for the effective delivery of the radioisotope to the tumor site while mitigating global in vivo radiotoxicity. Methods. In this work, core and core+2 shells (NPs with 2 additional layers of cold LaPO4 deposited on the core surfaces) LaPO4 nanoparticles (NPs)more » were synthesized containing either 223Ra or 225Ra/225Ac and the retention of the parents and daughters within the NPs in vitro was investigated. Results. The NPs crystallized in rhabdophane phase with mean diameters of 3.4 and 6.3 nm for core and core+2 shells, respectively. The core LaPO 4 NPs retained up to 88% of 223Ra over 35 days. However, in the core+2 shell NPs, the retention of 223Ra and its daughter, 211Pb, was improved to > 99.9% over 27 days. Additionally, the retention of 225Ra/225Ac parents was > 99.98% and ~80% for the 221Fr and 213Bi daughters over 35 days for the core+2 shell NPs. Conclusions. These results suggest that LaPO4 NPs are potentially effective carriers of radium isotopes.« less

  15. Chromium Isotope Fractionation During Reduction of Cr(VI) Under Saturated Flow Conditions

    SciTech Connect (OSTI)

    Jamieson-Hanes, Julia H.; Gibson, Blair D.; Lindsay, Matthew B.J.; Kim, Yeongkyoo; Ptacek, Carol J.; Blowes, David W.

    2012-10-25

    Chromium isotopes are potentially useful indicators of Cr(VI) reduction reactions in groundwater flow systems; however, the influence of transport on Cr isotope fractionation has not been fully examined. Laboratory batch and column experiments were conducted to evaluate isotopic fractionation of Cr during Cr(VI) reduction under both static and controlled flow conditions. Organic carbon was used to reduce Cr(VI) in simulated groundwater containing 20 mg L{sup -1} Cr(VI) in both batch and column experiments. Isotope measurements were performed on dissolved Cr on samples from the batch experiments, and on effluent and profile samples from the column experiment. Analysis of the residual solid-phase materials by scanning electron microscopy (SEM) and by X-ray absorption near edge structure (XANES) spectroscopy confirmed association of Cr(III) with organic carbon in the column solids. Decreases in dissolved Cr(VI) concentrations were coupled with increases in {delta}{sup 53}Cr, indicating that Cr isotope enrichment occurred during reduction of Cr(VI). The {delta}{sup 53}Cr data from the column experiment was fit by linear regression yielding a fractionation factor ({alpha}) of 0.9979, whereas the batch experiments exhibited Rayleigh-type isotope fractionation ({alpha} = 0.9965). The linear characteristic of the column {delta}{sup 53}Cr data may reflect the contribution of transport on Cr isotope fractionation.

  16. A micrometer-size movable light emitting area in a resonant tunneling light emitting diode

    SciTech Connect (OSTI)

    Pettinari, G., E-mail: giorgio.pettinari@cnr.it [School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD (United Kingdom); National Research Council (CNR), Institute for Photonics and Nanotechnologies (IFN-CNR), Via Cineto Romano 42, 00156 Roma (Italy); Balakrishnan, N.; Makarovsky, O.; Campion, R. P.; Patan, A. [School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD (United Kingdom)] [School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD (United Kingdom); Polimeni, A.; Capizzi, M. [CNISM-Dipartimento di Fisica, Sapienza Universit di Roma, P.le A. Moro 2, 00185 Roma (Italy)] [CNISM-Dipartimento di Fisica, Sapienza Universit di Roma, P.le A. Moro 2, 00185 Roma (Italy)

    2013-12-09

    We report on the fabrication of a micrometer-size movable light emitting area in a GaAs/AlAs quantum well resonant tunneling p-i-n diode. The spatial position of the micrometer-size light emitting area shifts linearly with increasing applied bias, up to 30??m for a bias increment of 0.2?V. Also, the simultaneous resonant tunneling injection of both electrons and holes into the quantum well states is achieved at specific positions of the diode, thus resulting in a tenfold increase of the electroluminescence intensity.

  17. Tunable, superconducting, surface-emitting teraherz source

    DOE Patents [OSTI]

    Welp, Ulrich; Koshelev, Alexei E.; Gray, Kenneth E.; Kwok, Wai-Kwong; Vlasko-Vlasov, Vitalii

    2009-10-27

    A compact, solid-state THz source based on the driven Josephson vortex lattice in a highly anisotropic superconductor such as Bi.sub.2Sr.sub.2CaCu.sub.2O.sub.8 that allows cw emission at tunable frequency. A second order metallic Bragg grating is used to achieve impedance matching and to induce surface emission of THz-radiation from a Bi.sub.2Sr.sub.2CaCu.sub.2O.sub.8 sample. Steering of the emitted THz beam is accomplished by tuning the Josephson vortex spacing around the grating period using a superimposed magnetic control field.

  18. Tunable, superconducting, surface-emitting teraherz source

    DOE Patents [OSTI]

    Welp, Ulrich; Koshelev, Alexei E.; Gray, Kenneth E.; Kwok, Wai-Kwong; Vlasko-Vlasov, Vitalii

    2010-05-11

    A compact, solid-state THz source based on the driven Josephson vortex lattice in a highly anisotropic superconductor such as Bi.sub.2Sr.sub.2CaCu.sub.2O.sub.8 that allows cw emission at tunable frequency. A second order metallic Bragg grating is used to achieve impedance matching and to induce surface emission of THz-radiation from a Bi.sub.2Sr.sub.2CaCu.sub.2O.sub.8 sample. Steering of the emitted THz beam is accomplished by tuning the Josephson vortex spacing around the grating period using a superimposed magnetic control field.

  19. Long wavelength vertical cavity surface emitting laser

    DOE Patents [OSTI]

    Choquette, Kent D.; Klem, John F.

    2005-08-16

    Selectively oxidized vertical cavity lasers emitting near 1300 nm using InGaAsN quantum wells are reported for the first time which operate continuous wave below, at and above room temperature. The lasers employ two n-type Al.sub.0.94 Ga.sub.0.06 As/GaAs distributed Bragg reflectors each with a selectively oxidized current aperture adjacent to the active region, and the top output mirror contains a tunnel junction to inject holes into the active region. Continuous wave single mode lasing is observed up to 55.degree. C.

  20. Transportation of medical isotopes

    SciTech Connect (OSTI)

    Nielsen, D.L.

    1997-11-19

    A Draft Technical Information Document (HNF-1855) is being prepared to evaluate proposed interim tritium and medical isotope production at the Fast Flux Test Facility (FFTF). This assessment examines the potential health and safety impacts of transportation operations associated with the production of medical isotopes. Incident-free and accidental impacts are assessed using bounding source terms for the shipment of nonradiological target materials to the Hanford Site, the shipment of irradiated targets from the FFTF to the 325 Building, and the shipment of medical isotope products from the 325 Building to medical distributors. The health and safety consequences to workers and the public from the incident-free transportation of targets and isotope products would be within acceptable levels. For transportation accidents, risks to works and the public also would be within acceptable levels. This assessment is based on best information available at this time. As the medical isotope program matures, this analysis will be revised, if necessary, to support development of a final revision to the Technical Information Document.

  1. Separation of sulfur isotopes

    DOE Patents [OSTI]

    DeWitt, Robert; Jepson, Bernhart E.; Schwind, Roger A.

    1976-06-22

    Sulfur isotopes are continuously separated and enriched using a closed loop reflux system wherein sulfur dioxide (SO.sub.2) is reacted with sodium hydroxide (NaOH) or the like to form sodium hydrogen sulfite (NaHSO.sub.3). Heavier sulfur isotopes are preferentially attracted to the NaHSO.sub.3, and subsequently reacted with sulfuric acid (H.sub.2 SO.sub.4) forming sodium hydrogen sulfate (NaHSO.sub.4) and SO.sub.2 gas which contains increased concentrations of the heavier sulfur isotopes. This heavy isotope enriched SO.sub.2 gas is subsequently separated and the NaHSO.sub.4 is reacted with NaOH to form sodium sulfate (Na.sub.2 SO.sub.4) which is subsequently decomposed in an electrodialysis unit to form the NaOH and H.sub.2 SO.sub.4 components which are used in the aforesaid reactions thereby effecting sulfur isotope separation and enrichment without objectionable loss of feed materials.

  2. An alpha–gamma coincidence spectrometer based on the Photon–Electron Rejecting Alpha Liquid Scintillation (PERALS®) system

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Cadieux, J. R.; Fugate, G. A.; King, III, G. S.

    2015-02-07

    Here, an alpha–gamma coincidence spectrometer has been developed for the measurement of selected actinide isotopes in the presence of high beta/gamma fields. The system is based on a PERALS® liquid scintillation counter for beta/alpha discrimination and was successfully tested with both high purity germanium and bismuth germanate, gamma-ray detectors using conventional analog electronics.

  3. Detecting alpha particles through scintillation in porous materials. Master`s thesis

    SciTech Connect (OSTI)

    Keillor, M.E.

    1994-12-01

    This thesis presents the results of a preliminary study of parameters essential to the development of a scintillation flow-cell detector with improved characteristics over existing cells. Such a detector with better than 10% alpha energy resolution could provide in situ capability to detect and identify important alpha-emitting radionuclides in dilute aqueous solutions. Gel-silica is a potential candidate that may provide the needed improvement in resolution while maintaining 100% detection efficiency; however, gel-silica with useful light output is yet to be developed. As a step toward realizing the system described, the dependence of alpha detection efficiency and intrinsic energy resolution on the phase dimensions in heterogeneous scintillation detectors is examined. Two main areas of this research are: (1) computer modeling of the geometric detection efficiency and intrinsic energy resolution in porous glass scintillation detectors, and (2) experiments designed to test model predictions and provide data on the detection of alphas in porous glass structures. Experimental emphasis is on alpha detection in gel-silica filled with liquid scintillant. Results show that phase dimensions must be considered in constructing a flow-cell detector for alpha spectroscopy, and that the dimensions available in gel-silica provide for excellent intrinsic energy resolution, as well as 100% detection efficiency.

  4. Workshop on Precision Measurements of $\\alpha_s$

    SciTech Connect (OSTI)

    Bethke, Siegfried; Hoang, Andre H.; Kluth, Stefan; Schieck, Jochen; Stewart, Iain W.; Aoki, S.; Beneke, M.; Bethke, S.; Blumlein, J.; Brambilla, N.; Brodsky, S.; /MIT, LNS

    2011-10-01

    These are the proceedings of the Workshop on Precision Measurements of {alpha}{sub s} held at the Max-Planck-Institute for Physics, Munich, February 9-11, 2011. The workshop explored in depth the determination of {alpha}{sub s}(m{sub Z}) in the {ovr MS} scheme from the key categories where high precision measurements are currently being made, including DIS and global PDF fits, {tau}-decays, electro-weak precision observables and Z-decays, event-shapes, and lattice QCD. These proceedings contain a short summary contribution from the speakers, as well as the lists of authors, conveners, participants, and talks.

  5. Isotope separation apparatus

    DOE Patents [OSTI]

    Arnush, Donald; MacKenzie, Kenneth R.; Wuerker, Ralph F.

    1980-01-01

    Isotope separation apparatus consisting of a plurality of cells disposed adjacent to each other in an evacuated container. A common magnetic field is established extending through all of the cells. A source of energetic electrons at one end of the container generates electrons which pass through the cells along the magnetic field lines. Each cell includes an array of collector plates arranged in parallel or in tandem within a common magnetic field. Sets of collector plates are disposed adjacent to each other in each cell. Means are provided for differentially energizing ions of a desired isotope by applying energy at the cyclotron resonant frequency of the desired isotope. As a result, the energized desired ions are preferentially collected by the collector plates.

  6. Electron emitting filaments for electron discharge devices

    DOE Patents [OSTI]

    Leung, K.N.; Pincosy, P.A.; Ehlers, K.W.

    1983-06-10

    Electrons are copiously emitted by a device comprising a loop-shaped filament made of lanthanum hexaboride. The filament is directly heated by an electrical current produced along the filament by a power supply connected to the terminal legs of the filament. To produce a filament, a diamond saw or the like is used to cut a slice from a bar made of lanthanum hexaboride. The diamond saw is then used to cut the slice into the shape of a loop which may be generally rectangular, U-shaped, hairpin-shaped, zigzag-shaped, or generally circular. The filaments provide high electron emission at a relatively low operating temperature, such as 1600/sup 0/C. To achieve uniform heating, the filament is formed with a cross section which is tapered between the opposite ends of the filament to compensate for nonuniform current distribution along the filament due to the emission of electrons from the filament.

  7. Electron emitting filaments for electron discharge devices

    DOE Patents [OSTI]

    Leung, Ka-Ngo; Pincosy, Philip A.; Ehlers, Kenneth W.

    1988-01-01

    Electrons are copiously emitted by a device comprising a loop-shaped filament made of lanthanum hexaboride. The filament is directly heated by an electrical current produced along the filament by a power supply connected to the terminal legs of the filament. To produce a filament, a diamond saw or the like is used to cut a slice from a bar made of lanthanum hexaboride. The diamond saw is then used to cut the slice into the shape of a loop which may be generally rectangular, U-shaped, hairpin-shaped, zigzag-shaped, or generally circular. The filaments provide high electron emission at a relatively low operating temperature, such as 1600.degree. C. To achieve uniform heating, the filament is formed with a cross section which is tapered between the opposite ends of the filament to compensate for non-uniform current distribution along the filament due to the emission of electrons from the filament.

  8. Photonic crystal surface-emitting lasers

    DOE Patents [OSTI]

    Chua, Song Liang; Lu, Ling; Soljacic, Marin

    2015-06-23

    A photonic-crystal surface-emitting laser (PCSEL) includes a gain medium electromagnetically coupled to a photonic crystal whose energy band structure exhibits a Dirac cone of linear dispersion at the center of the photonic crystal's Brillouin zone. This Dirac cone's vertex is called a Dirac point; because it is at the Brillouin zone center, it is called an accidental Dirac point. Tuning the photonic crystal's band structure (e.g., by changing the photonic crystal's dimensions or refractive index) to exhibit an accidental Dirac point increases the photonic crystal's mode spacing by orders of magnitudes and reduces or eliminates the photonic crystal's distributed in-plane feedback. Thus, the photonic crystal can act as a resonator that supports single-mode output from the PCSEL over a larger area than is possible with conventional PCSELs, which have quadratic band edge dispersion. Because output power generally scales with output area, this increase in output area results in higher possible output powers.

  9. Test chamber for alpha spectrometry

    DOE Patents [OSTI]

    Larsen, Robert P.

    1977-01-01

    Alpha emitters for low-level radiochemical analysis by measurement of alpha spectra are positioned precisely with respect to the location of a surface-barrier detector by means of a chamber having a removable threaded planchet holder. A pedestal on the planchet holder holds a specimen in fixed engagement close to the detector. Insertion of the planchet holder establishes an O-ring seal that permits the chamber to be pumped to a desired vacuum. The detector is protected against accidental contact and resulting damage.

  10. DEEP WATER ISOTOPIC CURRENT ANALYZER

    DOE Patents [OSTI]

    Johnston, W.H.

    1964-04-21

    A deepwater isotopic current analyzer, which employs radioactive isotopes for measurement of ocean currents at various levels beneath the sea, is described. The apparatus, which can determine the direction and velocity of liquid currents, comprises a shaft having a plurality of radiation detectors extending equidistant radially therefrom, means for releasing radioactive isotopes from the shaft, and means for determining the time required for the isotope to reach a particular detector. (AEC)

  11. Energy Savings Estimates of Light Emitting Diodes | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Estimates of Light Emitting Diodes Energy Savings Estimates of Light Emitting Diodes This report is an analysis of niche markets and applications for light emitting diodes (LEDs), undertaken on behalf of the U.S. Department of Energy nichefinalreport_january2011.pdf (677.78 KB) More Documents & Publications LED ADOPTION REPORT Energy Savings Potential of Solid-State Lighting in General Illumination Applications - Report 2010 U.S. Lighting Market Characterization

  12. Method for separating boron isotopes

    DOE Patents [OSTI]

    Rockwood, Stephen D.

    1978-01-01

    A method of separating boron isotopes .sup.10 B and .sup.11 B by laser-induced selective excitation and photodissociation of BCl.sub.3 molecules containing a particular boron isotope. The photodissociation products react with an appropriate chemical scavenger and the reaction products may readily be separated from undissociated BCl.sub.3, thus effecting the desired separation of the boron isotopes.

  13. Test Procedures for Integrated Light-Emitting Diode Lamps; Final...

    Broader source: Energy.gov (indexed) [DOE]

    Test Procedures for Integrated Light-Emitting Diode Lamps - Final Rule (532.58 KB) More Documents & Publications ISSUANCE 2015-06-25: Energy Conservation Program: Test Procedures ...

  14. Light-Emitting Diodes on Semipolar Bulk Gallium Nitride Substrate

    Broader source: Energy.gov [DOE]

    This project is producing high-efficiency semipolar light-emitting diodes (LEDs) on low-defect bulk gallium nitride (GaN) substrates.

  15. Light emitting device comprising phosphorescent materials for white light generation

    DOE Patents [OSTI]

    Thompson, Mark E.; Dapkus, P. Daniel

    2014-07-22

    The present invention relates to phosphors for energy downconversion of high energy light to generate a broadband light spectrum, which emit light of different emission wavelengths.

  16. Energy Savings Estimates of Light Emitting Diodes in Niche Lighting...

    Broader source: Energy.gov (indexed) [DOE]

    Estimates of Light Emitting Diodes in Niche Lighting Applications Prepared for: Building Technologies Program Office of Energy Efficiency and Renewable Energy U.S. Department of ...

  17. Supported palladium materials for isotope separation

    SciTech Connect (OSTI)

    Rutherford, W.M.; Ellis, R.E.; Abell, G.C.

    1988-01-21

    Several palladium packing materials were investigated for their suitability for use in the separation of hydrogen isotopes by displacement chromatography. The materials included palladium on Chromosorb and several formulations of palladium on commercially available alpha-alumina-based catalyst supports. All materials showed some degradation upon being subjected to repeated hydriding-dehydriding cycles; however, the degradation did not lead to unacceptably low permeability to gas flow. Dynamic performance of the packings was evaluated by displacement of deuterium with protium at several temperatures and flow rates. Isotopic exchange was generally rapid. However, high surface area packings (greater than 4 m/sup 2//g) yielded transition zones that were initially sharp, but had long ''tails'' at deuterium concentrations below 5%. Best results were obtained with a packing containing 48.2% palladium on Norton catalyst support No. SA5*21 (surface area = 0.33 m/sup 2//g). Improved performance was observed as the displacement temperature was increased to 80/sup 0/C from 22/sup 0/C. The slight decrease in equilibrium separation was more than offset by improved kinetics at the higher temperature. 19 figs., 6 tabs.

  18. Blue-emitting AlN:Eu{sup 2+} nitride phosphor for field emission displays

    SciTech Connect (OSTI)

    Hirosaki, N.; Xie, R.-J.; Inoue, K.; Sekiguchi, T.; Dierre, B.; Tamura, K.

    2007-08-06

    An Eu{sup 2+}-activated AlN phosphor was synthesized by firing the powder mixture of AlN, {alpha}-Si{sub 3}N{sub 4}, and Eu{sub 2}O{sub 3} at 2050 deg. C for 4 h under 1.0 MPa N{sub 2}. This nitride phosphor emits a strong blue color with the chromaticity coordinates of x=0.139 and y=0.106 at an accelerating voltage of 3 kV. The cathodoluminescence properties of AlN:Eu{sup 2+} was evaluated by utilizing it in the Spindt-type field emission display panel. It shows that the nitride phosphor exhibits higher brightness, higher color purity, lower saturation, and longer lifetime than the currently used Y{sub 2}SiO{sub 5}:Ce{sup 3+}, indicative of the suitability of the AlN:Eu{sup 2+} blue phosphor in field emission displays.

  19. AlphaWatt Ltd | Open Energy Information

    Open Energy Info (EERE)

    AlphaWatt Ltd Jump to: navigation, search Name: AlphaWatt Ltd Place: London, United Kingdom Zip: EC1V 4PY Sector: Solar Product: Solar project developer, plans to become an...

  20. Alpha buildings | Y-12 National Security Complex

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    buildings Alpha buildings Looking east to west at ground level, Y-12 building footers and utility lines continue to be constructed. The Alpha buildings are seen in the background

  1. Effects of emitted electron temperature on the plasma sheath

    SciTech Connect (OSTI)

    Sheehan, J. P.; Kaganovich, I. D.; Wang, H.; Raitses, Y.; Sydorenko, D.; Hershkowitz, N.

    2014-06-15

    It has long been known that electron emission from a surface significantly affects the sheath surrounding that surface. Typical fluid theory of a planar sheath with emitted electrons assumes that the plasma electrons follow the Boltzmann relation and the emitted electrons are emitted with zero energy and predicts a potential drop of 1.03T{sub e}/e across the sheath in the floating condition. By considering the modified velocity distribution function caused by plasma electrons lost to the wall and the half-Maxwellian distribution of the emitted electrons, it is shown that ratio of plasma electron temperature to emitted electron temperature significantly affects the sheath potential when the plasma electron temperature is within an order of magnitude of the emitted electron temperature. When the plasma electron temperature equals the emitted electron temperature the emissive sheath potential goes to zero. One dimensional particle-in-cell simulations corroborate the predictions made by this theory. The effects of the addition of a monoenergetic electron beam to the Maxwellian plasma electrons were explored, showing that the emissive sheath potential is close to the beam energy only when the emitted electron flux is less than the beam flux.

  2. Light emitting elastomer compositions and method of use

    DOE Patents [OSTI]

    McElhanon, James R.; Zifer, Thomas; Whinnery, LeRoy L.

    2004-11-23

    There is provided a light emitting device comprising a plurality of triboluminescent particles dispersed throughout an elastomeric body and activated by deforming the body in order to transfer mechanical energy to some portion of the particles. The light emitted by these mechanically excited particles is collected and directed into a light conduit and transmitted to a detector/indicator means.

  3. INTERACTIVE: How Much Carbon Do Countries Emit? | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    INTERACTIVE: How Much Carbon Do Countries Emit? INTERACTIVE: How Much Carbon Do Countries Emit? This interactive map is not viewable in your browser. Please view it in a modern browser. If you are using IE9, you can also view the interactive here

  4. Simulations of emission from microcavity tandem organic light-emitting diodes

    SciTech Connect (OSTI)

    Biswas, Rana; Xu, Chun; Zhao, Weijun; Liu, Rui; Shinar, Ruth; Shinar, Joseph

    2011-01-01

    Microcavity tandem organic light-emitting diodes (OLEDs) are simulated and compared to experimental results. The simulations are based on two complementary techniques: rigorous finite element solutions of Maxwell's equations and Fourier space scattering matrix solutions. A narrowing and blue shift of the emission spectrum relative to the noncavity single unit OLED is obtained both theoretically and experimentally. In the simulations, a distribution of emitting sources is placed near the interface of the electron transport layer tris(8-hydroxyquinoline) Al (Alq{sub 3}) and the hole transport layer (N,N'-bis(naphthalen-1-yl)-N,N'-bis(phenyl)benzidine) ({alpha}-NPB). Far-field electric field intensities are simulated. The simulated widths of the emission peaks also agree with the experimental results. The simulations of the 2-unit tandem OLEDs shifted the emission to shorter wavelength, in agreement with experimental measurements. The emission spectra's dependence on individual layer thicknesses also agreed well with measurements. Approaches to simulate and improve the light emission intensity from these OLEDs, in particular for white OLEDs, are discussed.

  5. Atmospheric Emitted Radiance Interferometer (AERI) Handbook

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Gero, Jonathan; Hackel, Denny; Garcia, Raymond

    2005-01-01

    The atmospheric emitted radiance interferometer (AERI) is a ground-based instrument that measures the downwelling infrared radiance from the Earth’s atmosphere. The observations have broad spectral content and sufficient spectral resolution to discriminate among gaseous emitters (e.g., carbon dioxide and water vapor) and suspended matter (e.g., aerosols, water droplets, and ice crystals). These upward-looking surface observations can be used to obtain vertical profiles of tropospheric temperature and water vapor, as well as measurements of trace gases (e.g., ozone, carbon monoxide, and methane) and downwelling infrared spectral signatures of clouds and aerosols.The AERI is a passive remote sounding instrument, employing a Fourier transform spectrometer operating in the spectral range 3.3–19.2 μm (520–3020 cm-1) at an unapodized resolution of 0.5 cm-1 (max optical path difference of 1 cm). The extended-range AERI (ER-AERI) deployed in dry climates, like in Alaska, have a spectral range of 3.3–25.0 μm (400–3020 cm-1) that allow measurements in the far-infrared region. Typically, the AERI averages views of the sky over a 16-second interval and operates continuously.

  6. Welding arc gap ionization device

    DOE Patents [OSTI]

    Schweikhardt, George M.

    1976-01-01

    An alpha emitting isotope is positioned near the tip of a TIG welding electrode so that the alpha radiation can provide an ionized path between the electrode and the workpiece.

  7. Efficient semiconductor light-emitting device and method

    DOE Patents [OSTI]

    Choquette, Kent D.; Lear, Kevin L.; Schneider, Jr., Richard P.

    1996-01-01

    A semiconductor light-emitting device and method. The semiconductor light-emitting device is provided with at least one control layer or control region which includes an annular oxidized portion thereof to channel an injection current into the active region, and to provide a lateral refractive index profile for index guiding the light generated within the device. A periodic composition grading of at least one of the mirror stacks in the device provides a reduced operating voltage of the device. The semiconductor light-emitting device has a high efficiency for light generation, and may be formed either as a resonant-cavity light-emitting diode (RCLED) or as a vertical-cavity surface-emitting laser (VCSEL).

  8. Efficient semiconductor light-emitting device and method

    DOE Patents [OSTI]

    Choquette, K.D.; Lear, K.L.; Schneider, R.P. Jr.

    1996-02-20

    A semiconductor light-emitting device and method are disclosed. The semiconductor light-emitting device is provided with at least one control layer or control region which includes an annular oxidized portion thereof to channel an injection current into the active region, and to provide a lateral refractive index profile for index guiding the light generated within the device. A periodic composition grading of at least one of the mirror stacks in the device provides a reduced operating voltage of the device. The semiconductor light-emitting device has a high efficiency for light generation, and may be formed either as a resonant-cavity light-emitting diode (RCLED) or as a vertical-cavity surface-emitting laser (VCSEL). 12 figs.

  9. ISOTOPE SEPARATING APPARATUS CONTROL

    DOE Patents [OSTI]

    Barnes, S.W.

    1959-08-25

    An improved isotope separating apparatus of the electromagnetic type, commonly referred to as a calutron, is described. Improvements in detecting and maintaining optimum position and focus of the ion beam are given. The calutron collector is provided with an additional electrode insulated from and positioned between the collecting pockets. The ion beams are properly positioned and focused until the deionizing current which flows from ground to this additional electrode ts a minimum.

  10. Laser isotope separation of erbium and other isotopes

    DOE Patents [OSTI]

    Haynam, Christopher A.; Worden, Earl F.

    1995-01-01

    Laser isotope separation is accomplished using at least two photoionization pathways of an isotope simultaneously, where each pathway comprises two or more transition steps. This separation method has been applied to the selective photoionization of erbium isotopes, particularly for the enrichment of .sup.167 Er. The hyperfine structure of .sup.167 Er was used to find two three-step photoionization pathways having a common upper energy level.

  11. Laser isotope separation of erbium and other isotopes

    DOE Patents [OSTI]

    Haynam, C.A.; Worden, E.F.

    1995-08-22

    Laser isotope separation is accomplished using at least two photoionization pathways of an isotope simultaneously, where each pathway comprises two or more transition steps. This separation method has been applied to the selective photoionization of erbium isotopes, particularly for the enrichment of {sup 167}Er. The hyperfine structure of {sup 167}Er was used to find two three-step photoionization pathways having a common upper energy level. 3 figs.

  12. Comparison of MCNP6 and experimental results for neutron counts, Rossi-{alpha}, and Feynman-{alpha} distributions

    SciTech Connect (OSTI)

    Talamo, A.; Gohar, Y.; Sadovich, S.; Kiyavitskaya, H.; Bournos, V.; Fokov, Y.; Routkovskaya, C.

    2013-07-01

    MCNP6, the general-purpose Monte Carlo N-Particle code, has the capability to perform time-dependent calculations by tracking the time interval between successive events of the neutron random walk. In fixed-source calculations for a subcritical assembly, the zero time value is assigned at the moment the neutron is emitted by the external neutron source. The PTRAC and F8 cards of MCNP allow to tally the time when a neutron is captured by {sup 3}He(n, p) reactions in the neutron detector. From this information, it is possible to build three different time distributions: neutron counts, Rossi-{alpha}, and Feynman-{alpha}. The neutron counts time distribution represents the number of neutrons captured as a function of time. The Rossi-a distribution represents the number of neutron pairs captured as a function of the time interval between two capture events. The Feynman-a distribution represents the variance-to-mean ratio, minus one, of the neutron counts array as a function of a fixed time interval. The MCNP6 results for these three time distributions have been compared with the experimental data of the YALINA Thermal facility and have been found to be in quite good agreement. (authors)

  13. Synthesis and characterization of lanthanum phosphate nanoparticles as carriers for 223Ra and 225Ra for targeted alpha therapy

    SciTech Connect (OSTI)

    Rojas, J. V.; Woodward, J. D.; Chen, N.; Rondinone, A. J.; Castano, C. H.; Mirzadeh, S.

    2015-03-19

    Targeted alpha therapy (TAT) has the potential for killing specific tumor cells with minimum collateral damage to surrounding healthy tissue. Radionuclides such as 223Ra, 225Ra, and 225Ac are of special interest for radiotherapeutic applications as they emit multiple -particles during their decay. Utilizing appropriate carriers capable of retaining both the parent radioisotope as well as daughter products is important for the effective delivery of the radioisotope to the tumor site while mitigating global in vivo radiotoxicity. Methods. In this work, core and core+2 shells (NPs with 2 additional layers of cold LaPO4 deposited on the core surfaces) LaPO4 nanoparticles (NPs) were synthesized containing either 223Ra or 225Ra/225Ac and the retention of the parents and daughters within the NPs in vitro was investigated. Results. The NPs crystallized in rhabdophane phase with mean diameters of 3.4 and 6.3 nm for core and core+2 shells, respectively. The core LaPO 4 NPs retained up to 88% of 223Ra over 35 days. However, in the core+2 shell NPs, the retention of 223Ra and its daughter, 211Pb, was improved to > 99.9% over 27 days. Additionally, the retention of 225Ra/225Ac parents was > 99.98% and ~80% for the 221Fr and 213Bi daughters over 35 days for the core+2 shell NPs. Conclusions. These results suggest that LaPO4 NPs are potentially effective carriers of radium isotopes.

  14. Stable isotope research pool inventory

    SciTech Connect (OSTI)

    Not Available

    1988-02-01

    This report contains a listing of electromagnetically separated stable isotopes which are available at the Oak Ridge National Laboratory for distribution for nondestructive research use on a loan basis. This inventory includes all samples of stable isotopes in the Research Materials Collection and does not designate whether a sample is out on loan or is in reprocessing. For some of the high-abundance, naturally occurring isotopes, larger amounts can be made available; for example, Ca-40 and Fe-56.

  15. Stable isotope research pool inventory

    SciTech Connect (OSTI)

    Not Available

    1982-01-01

    This report contains a listing of electromagnetically separated stable isotopes which are available for distribution within the United States for nondestructive research use from the Oak Ridge National Laboratory on a loan basis. This inventory includes all samples of stable isotopes in the Material Research Collection and does not designate whether a sample is out on loan or in reprocessing. For some of the high abundance naturally occurring isotopes, larger amounts can be made available; for example, Ca-40 and Fe-56.

  16. Stable isotope research pool inventory

    SciTech Connect (OSTI)

    Not Available

    1984-03-01

    This report contains a listing of electromagnetically separated stable isotopes which are available at the Oak Ridge National Laboratory for distribution for nondestructive research use on a loan basis. This inventory includes all samples of stable isotopes in the Research Materials Collection and does not designate whether a sample is out on loan or is in reprocessing. For some of the high abundance naturally occurring isotopes, larger amounts can be made available; for example, Ca-40 and Fe-56.

  17. RAPID FUSION METHOD FOR DETERMINATION OF PLUTONIUM ISOTOPES IN LARGE RICE SAMPLES

    SciTech Connect (OSTI)

    Maxwell, S.

    2013-03-01

    A new rapid fusion method for the determination of plutonium in large rice samples has been developed at the Savannah River National Laboratory (Aiken, SC, USA) that can be used to determine very low levels of plutonium isotopes in rice. The recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid, reliable radiochemical analyses for radionuclides in environmental and food samples. Public concern regarding foods, particularly foods such as rice in Japan, highlights the need for analytical techniques that will allow very large sample aliquots of rice to be used for analysis so that very low levels of plutonium isotopes may be detected. The new method to determine plutonium isotopes in large rice samples utilizes a furnace ashing step, a rapid sodium hydroxide fusion method, a lanthanum fluoride matrix removal step, and a column separation process with TEVA Resin� cartridges. The method can be applied to rice sample aliquots as large as 5 kg. Plutonium isotopes can be determined using alpha spectrometry or inductively-coupled plasma mass spectrometry (ICP-MS). The method showed high chemical recoveries and effective removal of interferences. The rapid fusion technique is a rugged sample digestion method that ensures that any refractory plutonium particles are effectively digested. The MDA for a 5 kg rice sample using alpha spectrometry is 7E-5 mBq g{sup -1}. The method can easily be adapted for use by ICP-MS to allow detection of plutonium isotopic ratios.

  18. Alpha

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    effect of Alfve ´ n waves and current drive in reversed-field pinches C. Litwin a) and S. C. Prager Department of Physics, University of Wisconsin, 1150 University Avenue, Madison, Wisconsin 53706 ͑Received 9 September 1997; accepted 5 December 1997͒ Circularly polarized Alfve ´ n waves give rise to an ␣-dynamo effect that can be exploited to drive parallel current. In a ''laminar'' magnetic the effect is weak and does not give rise to significant currents for realistic parameters ͑e.g.,

  19. Isotopically labeled compositions and method

    DOE Patents [OSTI]

    Schmidt, Jurgen G.; Kimball, David B.; Alvarez, Marc A.; Williams, Robert F.; Martinez, Rudolfo A.

    2011-07-12

    Compounds having stable isotopes .sup.13C and/or .sup.2H were synthesized from precursor compositions having solid phase supports or affinity tags.

  20. Advanced isotope separation

    SciTech Connect (OSTI)

    Not Available

    1982-05-04

    The Study Group briefly reviewed the technical status of the three Advanced Isotope Separation (AIS) processes. It also reviewed the evaluation work that has been carried out by DOE's Process Evaluation Board (PEB) and the Union Carbide Corporation-Nuclear Division (UCCND). The Study Group briefly reviewed a recent draft assessment made for DOE staff of the nonproliferation implications of the AIS technologies. The staff also very briefly summarized the status of GCEP and Advanced Centrifuge development. The Study Group concluded that: (1) there has not been sufficient progress to provide a firm scientific, technical or economic basis on which to select one of the three competing AIS processes for full-scale engineering development at this time; and (2) however, should budgetary restraints or other factors force such a selection, we believe that the evaluation process that is being carried out by the PEB provides the best basis available for making a decision. The Study Group recommended that: (1) any decisions on AIS processes should include a comparison with gas centrifuge processes, and should not be made independently from the plutonium isotope program; (2) in evaluating the various enrichment processes, all applicable costs (including R and D and sales overhead) and an appropriate discounting approach should be included in order to make comparisons on a private industry basis; (3) if the three AIS programs continue with limited resources, the work should be reoriented to focus only on the most pressing technical problems; and (4) if a decision is made to develop the Atomic Vapor Laser Isotope Separation process, the solid collector option should be pursued in parallel to alleviate the potential program impact of liquid collector thermal control problems.

  1. Chromatographic hydrogen isotope separation

    DOE Patents [OSTI]

    Aldridge, F.T.

    Intermetallic compounds with the CaCu/sub 5/ type of crystal structure, particularly LaNiCo/sub 4/ and CaNi/sub 5/, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation column. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale multi-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen cn produce large quantities of heavy water at an effective cost for use in heavy water reactors.

  2. ISOTOPE FRACTIONATION PROCESS

    DOE Patents [OSTI]

    Clewett, G.H.; Lee, DeW.A.

    1958-05-20

    A new method is described for isotopic enrichment of uranium. It has been found that when an aqueous acidic solution of ionic tetravalent uraniunn is contacted with chelate complexed tetravalent uranium, the U/sup 238/ preferentially concentrates in the complexed phase while U/sup 235/ concentrates in the ionic phase. The effect is enhanced when the chelate compound is water insoluble and is dissolved in a water-immiscible organic solvent. Cupferron is one of a number of sultable complexing agents, and chloroform is a suitable organic solvent.

  3. Chromatographic hydrogen isotope separation

    DOE Patents [OSTI]

    Aldridge, Frederick T.

    1981-01-01

    Intermetallic compounds with the CaCu.sub.5 type of crystal structure, particularly LaNiCo.sub.4 and CaNi.sub.5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation colum. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale mutli-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors.

  4. Alpha and gamma radioysis of nuclear solvent etxraction ligands used for An(III) and Ln(III) Separations

    SciTech Connect (OSTI)

    Stephen P. Mezyk; Bruce J. Mincher; Christian Ekberg; Gunnar Skarnemark

    2013-05-01

    The separation of the minor actinides from dissolved nuclear fuel remains a major challenge in developing large-scale waste separations processes. One important criterion is that all these processes must be robust under high acidity and radiation dose conditions. Here we have investigated the TRUEX ligand CMPO in dodecane, comparing the effects of gamma (60Co) with alpha irradiation using isotopic alpha sources (244Cm, 211At) experiments. The radiolytically-based CMPO decomposition efficiencies are approximately the same for both types of radiolysis, with the overall decomposition being significantly less when this formulation is irradiated in contact with aqueous acid.

  5. Demonstration Assessment of Light Emitting Diode (LED) Street...

    Energy Savers [EERE]

    Demonstration Assessment of Light Emitting Diode (LED) Street Lighting Host Site: City of Oakland, California Final Report prepared in support of the U.S. DOE Solid-State Lighting ...

  6. Demonstration Assessment of Light-Emitting Diode (LED) Roadway Lighting

    SciTech Connect (OSTI)

    Kinzey, B. R.; Myer, M. A.

    2009-11-01

    A U.S. Department of Energy Solid-State Lighting Gateway Report on a Demonstration Assessment of Light-Emitting Diode (LED) Roadway Lighting in Lija Loop, Portland, Oregon.

  7. Isotope Program Transportation | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Isotope Program Transportation Isotope Program Transportation Isotope Program Transportation (894.11 KB) More Documents & Publications Nuclear Fuel Storage and Transportation Planning Project Overview Section 180(c) Ad Hoc Working Group DOE Office of Nuclear Energy

  8. High gas flow alpha detector

    DOE Patents [OSTI]

    Bolton, R.D.; Bounds, J.A.; Rawool-Sullivan, M.W.

    1996-05-07

    An alpha detector for application in areas of high velocity gas flows, such as smokestacks and air vents. A plurality of spaced apart signal collectors are placed inside an enclosure, which would include smokestacks and air vents, in sufficient numbers to substantially span said enclosure so that gas ions generated within the gas flow are electrostatically captured by the signal collector means. Electrometer means and a voltage source are connected to the signal collectors to generate an electrical field between adjacent signal collectors, and to indicate a current produced through collection of the gas ions by the signal collectors. 4 figs.

  9. High gas flow alpha detector

    DOE Patents [OSTI]

    Bolton, Richard D.; Bounds, John A.; Rawool-Sullivan, Mohini W.

    1996-01-01

    An alpha detector for application in areas of high velocity gas flows, such as smokestacks and air vents. A plurality of spaced apart signal collectors are placed inside an enclosure, which would include smokestacks and air vents, in sufficient numbers to substantially span said enclosure so that gas ions generated within the gas flow are electrostatically captured by the signal collector means. Electrometer means and a voltage source are connected to the signal collectors to generate an electrical field between adjacent signal collectors, and to indicate a current produced through collection of the gas ions by the signal collectors.

  10. Identification of {gamma} rays from {sup 172}Au and {alpha} decays of {sup 172}Au, {sup 168}Ir, and {sup 164}Re

    SciTech Connect (OSTI)

    Hadinia, B.; Cederwall, B.; Andgren, K.; Baeck, T.; Johnson, A.; Khaplanov, A.; Wyss, R.; Page, R. D.; Grahn, T.; Paul, E. S.; Sandzelius, M.; Scholey, C.; Greenlees, P. T.; Jakobsson, U.; Jones, P. M.; Julin, R.; Juutinen, J.; Ketelhut, S.; Leino, M.; Nyman, M.

    2009-12-15

    The very neutron deficient odd-odd nucleus {sup 172}Au was studied in reactions of 342 and 348 MeV {sup 78}Kr beams with an isotopically enriched {sup 96}Ru target. The {alpha} decays previously reported for {sup 172}Au were confirmed and the decay chain extended down to {sup 152}Tm through the discovery of a new {alpha}-decaying state in {sup 164}Re[E{sub {alpha}}=5623(10) keV; t{sub 1/2}=864{sub -110}{sup +150} ms; b{sub {alpha}}=3(1)%]. Fine structure in these {alpha} decays of {sup 172}Au and {sup 168}Ir were identified. A new {alpha}-decaying state was also observed and assigned as the ground state in {sup 172}Au[E{sub {alpha}}=6762(10) keV; t{sub 1/2}=22{sub -5}{sup +6} ms]. This decay chain was also correlated down to {sup 152}Tm through previously reported {alpha} decays. Prompt {gamma} rays from excited states in {sup 172}Au have been identified using the recoil-decay tagging technique. The partial level scheme constructed for {sup 172}Au indicates that it has an irregular structure. Possible configurations of the {alpha}-decaying states in {sup 172}Au are discussed in terms of the systematics of nuclei in this region and total Routhian surface calculations.

  11. Nanoscale engineering boosts performance of quantum dot light emitting

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    diodes Quantum dot light emitting diodes Nanoscale engineering boosts performance of quantum dot light emitting diodes Quantum dots are nano-sized semiconductor particles whose emission color can be tuned by simply changing their dimensions. October 25, 2013 Postdoctoral researcher Young-Shin Park characterizing emission spectra of LEDs in the Los Alamos National Laboratory optical laboratory. Postdoctoral researcher Young-Shin Park characterizing emission spectra of LEDs in the Los Alamos

  12. Organic light emitting device structure for obtaining chromaticity stability

    DOE Patents [OSTI]

    Tung, Yeh-Jiun; Ngo, Tan

    2007-05-01

    The present invention relates to organic light emitting devices (OLEDs). The devices of the present invention are efficient white or multicolored phosphorescent OLEDs which have a high color stability over a wide range of luminances. The devices of the present invention comprise an emissive region having at least two emissive layers, with each emissive layer comprising a different host and emissive dopant, wherein at least one of the emissive dopants emits by phosphorescence.

  13. Organic light emitting device structures for obtaining chromaticity stability

    DOE Patents [OSTI]

    Tung, Yeh-Jiun; Lu, Michael; Kwong, Raymond C.

    2005-04-26

    The present invention relates to organic light emitting devices (OLEDs). The devices of the present invention are efficient white or multicolored phosphorescent OLEDs which have a high color stability over a wide range of luminances. The devices of the present invention comprise an emissive region having at least two emissive layers, with each emissive layer comprising a different host and emissive dopant, wherein at least one of the emissive dopants emits by phosphorescence.

  14. Demonstration Assessment of Light-Emitting Diode Parking Structure Lighting

    Office of Scientific and Technical Information (OSTI)

    at U.S. Department of Labor Headquarters (Technical Report) | SciTech Connect Demonstration Assessment of Light-Emitting Diode Parking Structure Lighting at U.S. Department of Labor Headquarters Citation Details In-Document Search Title: Demonstration Assessment of Light-Emitting Diode Parking Structure Lighting at U.S. Department of Labor Headquarters This report documents a solid-state lighting (SSL) technology demonstration at the parking structure of the U.S. Department of Labor (DOL)

  15. Phonon coherence in isotopic silicon superlattices

    SciTech Connect (OSTI)

    Frieling, R.; Radek, M.; Eon, S.; Bracht, H.; Wolf, D. E.

    2014-09-29

    Recent experimental and theoretical investigations have confirmed that a reduction in thermal conductivity of silicon is achieved by isotopic silicon superlattices. In the present study, non-equilibrium molecular dynamics simulations are performed to identify the isotope doping and isotope layer ordering with minimum thermal conductivity. Furthermore, the impact of isotopic intermixing at the superlattice interfaces on phonon transport is investigated. Our results reveal that the coherence of phonons in isotopic Si superlattices is prevented if interfacial mixing of isotopes is considered.

  16. Method of separating boron isotopes

    DOE Patents [OSTI]

    Jensen, Reed J.; Thorne, James M.; Cluff, Coran L.; Hayes, John K.

    1984-01-01

    A method of boron isotope enrichment involving the isotope preferential photolysis of (2-chloroethenyl)dichloroborane as the feed material. The photolysis can readily be achieved with CO.sub.2 laser radiation and using fluences significantly below those required to dissociate BCl.sub.3.

  17. Method of separating boron isotopes

    DOE Patents [OSTI]

    Jensen, R.J.; Thorne, J.M.; Cluff, C.L.

    1981-01-23

    A method of boron isotope enrichment involving the isotope preferential photolysis of (2-chloroethenyl)-dichloroborane as the feed material. The photolysis can readily by achieved with CO/sub 2/ laser radiation and using fluences significantly below those required to dissociate BCl/sub 3/.

  18. Stable isotope research pool inventory

    SciTech Connect (OSTI)

    Not Available

    1980-12-01

    This report contains a listing of electromagnetically separated stable isotopes which are available for distribution within the United States for non-destructive research use from the Oak Ridge National Laboratory on a loan basis. This inventory includes all samples of stable isotopes in the Materials Research Collection and does not designate whether a sample is out on loan or in reprocessing.

  19. 2014-05-16 Issuance: Test Procedures for Integrated Light-Emitting...

    Broader source: Energy.gov (indexed) [DOE]

    notice of proposed rulemaking regarding test procedures for integrated light-emitting ... to this document. 2014-05-16 Issuance: Test Procedures for Integrated Light-Emitting ...

  20. 2014-06-18 Issuance: Test Procedure for Integrated Light-Emitting...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    18 Issuance: Test Procedure for Integrated Light-Emitting Diode Lamps; Supplemental Notice of Proposed Rulemaking 2014-06-18 Issuance: Test Procedure for Integrated Light-Emitting ...

  1. Double Beta Decay in Xenon-136: Measuring the Neutrino-Emitting...

    Office of Scientific and Technical Information (OSTI)

    Title: Double Beta Decay in Xenon-136: Measuring the Neutrino-Emitting Mode and Searching for Majoron-Emitting Modes Authors: Herrin, Steven ; Stanford U., Phys. Dept. SLAC ...

  2. Heavy Isotopes Lead Materials Management Organization (LMMO)...

    Office of Scientific and Technical Information (OSTI)

    Heavy Isotopes Lead Materials Management Organization (LMMO) Update Citation Details In-Document Search Title: Heavy Isotopes Lead Materials Management Organization (LMMO) Update ...

  3. Isotopic Trends in Production of Superheavies

    SciTech Connect (OSTI)

    Antonenko, N.V.; Adamian, G.G.; Zubov, A.S.; Scheid, W.

    2005-11-21

    The isotopic trends are discussed for cold and hot fusion reactions leading to superheavies. The possibilities of production of new isotopes in incomplete fusion reactions are treated.

  4. Color tuning of light-emitting-diodes by modulating the concentration of red-emitting silicon nanocrystal phosphors

    SciTech Connect (OSTI)

    Barillaro, G. Strambini, L. M.

    2014-03-03

    Luminescent forms of nanostructured silicon have received significant attention in the context of quantum-confined light-emitting devices thanks to size-tunable emission wavelength and high-intensity photoluminescence, as well as natural abundance, low cost, and non-toxicity. Here, we show that red-emitting silicon nanocrystal (SiN) phosphors, obtained by electrochemical erosion of silicon, allow for effectively tuning the color of commercial light-emitting-diodes (LEDs) from blue to violet, magenta, and red, by coating the LED with polydimethylsiloxane encapsulating different SiN concentrations. High reliability of the tuning process, with respect to SiN fabrication and concentration, and excellent stability of the tuning color, with respect to LED bias current, is demonstrated through simultaneous electrical/optical characterization of SiN-modified commercial LEDs, thus envisaging exciting perspectives for silicon nanocrystals in the field of light-emitting applications.

  5. Isotope separation by laser means

    DOE Patents [OSTI]

    Robinson, C. Paul; Jensen, Reed J.; Cotter, Theodore P.; Greiner, Norman R.; Boyer, Keith

    1982-06-15

    A process for separating isotopes by selective excitation of isotopic species of a volatile compound by tuned laser light. A highly cooled gas of the volatile compound is produced in which the isotopic shift is sharpened and defined. Before substantial condensation occurs, the cooled gas is irradiated with laser light precisely tuned to a desired wavelength to selectively excite a particular isotopic species in the cooled gas. The laser light may impart sufficient energy to the excited species to cause it to undergo photochemical reaction or even to photoionize. Alternatively, a two-photon irradiation may be applied to the cooled gas to induce photochemical reaction or photoionization. The process is particularly applicable to the separation of isotopes of uranium and plutonium.

  6. Beta/alpha continuous air monitor

    DOE Patents [OSTI]

    Becker, Gregory K.; Martz, Dowell E.

    1989-01-01

    A single deep layer silicon detector in combination with a microcomputer, recording both alpha and beta activity and the energy of each pulse, distinguishing energy peaks using a novel curve fitting technique to reduce the natural alpha counts in the energy region where plutonium and other transuranic alpha emitters are present, and using a novel algorithm to strip out radon daughter contribution to actual beta counts.

  7. Beta/alpha continuous air monitor

    DOE Patents [OSTI]

    Becker, G.K.; Martz, D.E.

    1988-06-27

    A single deep layer silicon detector in combination with a microcomputer, recording both alpha and beta activity and the energy of each pulse, distinquishing energy peaks using a novel curve fitting technique to reduce the natural alpha counts in the energy region where plutonium and other transuranic alpha emitters are present, and using a novel algorithm to strip out radon daughter contribution to actual beta counts. 7 figs.

  8. Alternative methods for degradation studies by alpha radiolysis: tributyl phosphate and CMPO

    SciTech Connect (OSTI)

    Pearson, J.; Nilsson, M.; Miller, G.E.

    2013-07-01

    Solvent extraction separation processes used in the recycling of used nuclear fuel are susceptible to radiolytic damage from radioactive isotopes present in used fuel. Studying the respective effects on matter of both low linear energy transfer (LET) radiation such as gamma radiation and high LET such as alpha radiation will allow for accurate prediction and modeling of process performance losses with respect to dose. The effects of gamma radiation on solvent extraction ligands have been more extensively studied than the effects of alpha radiation due to the inherent difficulty in producing a sufficient and confluent dose of alpha particles within a sample without leaving the sample contaminated with long lived radioactive isotopes. We have developed a method for studying the effects of high LET radiation in situ via {sup 10}B activation and the high LET particles that result from the {sup 10}B(n,a){sup 7}Li reaction which follows. In this study we applied this method to organic solutions of tributyl phosphate (TBP) and CMPO (compound octylphenyl-N, N-diisobutyl-carbamoyl methyl phosphine oxide) representing the PUREX and TRUEX processes respectively. Rates of degradation of TBP and CMPO and their respective degradation products in the presence of both high and low LET radiation are presented and compared to values reported in the literature. Preliminary data appears to show decreased degradation of CMPO in the presence of an aqueous acidic phase, which agrees with other studies performed on TBP solutions. (authors)

  9. Alpha Renewable Energy | Open Energy Information

    Open Energy Info (EERE)

    Renewable Energy Jump to: navigation, search Name: Alpha Renewable Energy Place: Atlanta, Georgia Sector: Biomass Product: Manufacturer of biomass wood gas stoves and standalone...

  10. SHOE V.1.5 ALPHA

    Energy Science and Technology Software Center (OSTI)

    002913MLTPL00 Sandia Higher Order Elements (SHOE) v 0.5 alpha http://midas3.kitware.com/midas/folder/10328

  11. SU-E-J-03: A Comprehensive Comparison Between Alpha and Beta Emitters for Cancer Radioimmunotherapy

    SciTech Connect (OSTI)

    Huang, C.Y.; Guatelli, S; Oborn, B; Allen, B

    2014-06-01

    Purpose: The purpose of this study is to perform a comprehensive comparison of the therapeutic efficacy and cytotoxicity of alpha and beta emitters for Radioimmunotherapy (RIT). For each stage of cancer development, specific models were built for the separate objectives of RIT to be addressed:a) kill isolated cancer cells in transit in the lymphatic and vascular circulation,b) regress avascular cell clusters,c) regress tumor vasculature and tumors. Methods: Because of the nature of short range, high LET alpha and long energy beta radiation and heterogeneous antigen expression among cancer cells, the microdosimetric approach is essential for the RIT assessment. Geant4 based microdosimetric models are developed for the three different stages of cancer progression: cancer cells, cell clusters and tumors. The energy deposition, specific energy resulted from different source distribution in the three models was calculated separately for 4 alpha emitting radioisotopes ({sup 211}At, {sup 213}Bi, {sup 223}Ra and {sup 225}Ac) and 6 beta emitters ({sup 32}P, {sup 33}P, {sup 67}Cu, {sup 90}Y, {sup 131}I and {sup 177}Lu). The cell survival, therapeutic efficacy and cytotoxicity are determined and compared between alpha and beta emitters. Results: We show that internal targeted alpha radiation has advantages over beta radiation for killing isolated cancer cells, regressing small cell clusters and also solid tumors. Alpha particles have much higher dose specificity and potency than beta particles. They can deposit 3 logs more dose than beta emitters to single cells and solid tumor. Tumor control probability relies on deep penetration of radioisotopes to cancer cell clusters and solid tumors. Conclusion: The results of this study provide a quantitative understanding of the efficacy and cytotoxicity of RIT for each stage of cancer development.

  12. Light-emitting device with organic electroluminescent material and photoluminescent materials

    DOE Patents [OSTI]

    McNulty, Thomas Francis; Duggal, Anil Raj; Turner, Larry Gene; Shiang, Joseph John

    2005-06-07

    A light-emitting device comprises a light-emitting member, which comprises two electrodes and an organic electroluminescent material disposed between the electrodes, and at least one organic photoluminescent ("PL") material. The light-emitting member emits light having a first spectrum in response to a voltage applied across the two electrodes. The organic PL material absorbs a portion of the light emitted by the light-emitting member and emits light having second spectrum different than the first spectrum. The light-emitting device can include an inorganic PL material that absorbs another portion of the light emitted from the light-emitting member and emits light having a third spectrum different than both the first and the second spectra.

  13. Kinetic deuterium isotope effects on deamination and N-hydroxylation of cyclohexylamine by rabbit liver microsomes

    SciTech Connect (OSTI)

    Kurebayashi, H.

    1989-04-01

    Deuterium isotope effects on the kinetic parameters for deamination and N-hydroxylation of cyclohexylamine (CHA) catalyzed by rabbit liver microsomes with NADPH are investigated. Both reactions are inhibited by carbon monoxide and have the characteristics of typical cytochrome P450-dependent monooxygenase reactions. A small and significant deuterium isotope effect operates in the oxidative deamination of CHA. The apparent isotope effects, i.e., VH/VD and (V/K)H/(V/K)D ratios for deamination, are 1.75 and 1.8-2.3, respectively. On the basis of N-hydroxylation, the VH/VD and (V/K)H/(V/K)D ratios are 0.8-0.9. The N-hydroxylation rate of alpha-deuterated CHA (D-CHA) is somewhat higher than that of CHA. The increased increment of hydroxylamine formation seems to coincide with the decreased amount of deamination. Substitution of deuterium in the alpha-position of CHA results in metabolic switching of cytochrome P450 from deamination to N-hydroxylation with low deuterium isotope effects. The data are interpreted in terms of an initial one-electron abstraction from the nitrogen to form an aminium cation radical followed by recombination with iron-bound hydroxyl radical leading to N-hydroxylamine, or followed by alpha-carbon deprotonation to form a neutral carbon radical. The latter can lead to a carbinolamine intermediate for deamination by way of amine or recombination with nascent iron-bound hydroxyl radical. The relative rates of the reactions depend on the alpha-carbon deprotonation rates of amines.

  14. Container for hydrogen isotopes

    DOE Patents [OSTI]

    Solomon, David E.

    1977-01-01

    A container for the storage, shipping and dispensing of hydrogen isotopes such as hydrogen, deuterium, tritium, or mixtures of the same which has compactness, which is safe against fracture or accident, and which is reusable. The container consists of an outer housing with suitable inlet and outlet openings and electrical feed elements, the housing containing an activated sorber material in the form, for example, of titanium sponge or an activated zirconium aluminate cartridge. The gas to be stored is introduced into the chamber under conditions of heat and vacuum and will be retained in the sorber material. Subsequently, it may be released by heating the unit to drive off the stored gas at desired rates.

  15. Utilizing Isotopic Uranium Ratios in Groundwater Evaluations at FUSRAP Sites

    SciTech Connect (OSTI)

    Frederick, W.T.; Keil, K.G.; Rhodes, M.C.; Peterson, J.M.; MacDonell, M.M.

    2007-07-01

    The U.S. Army Corps of Engineers Buffalo District is evaluating environmental radioactive contamination at several Formerly Utilized Sites Remedial Action Program (FUSRAP) sites throughout New York, Pennsylvania, Ohio, and Indiana. The investigations follow the process defined in the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA). Groundwater data from the Niagara Falls Storage Site (NFSS) in Lewiston, New York were evaluated for isotopic uranium ratios, specifically uranium-234 versus uranium-238 (U- 234 and U-238, respectively), and the results were presented at Waste Management 2006. Since uranium naturally occurs in all groundwater, it can be difficult to distinguish where low-concentration impacts from past releases differ from the high end of a site-specific natural background range. In natural groundwater, the ratio of U-234 to U-238 exceeds 1 (unity) due to the alpha particle recoil effect, in which U-234 is preferentially mobilized to groundwater from adjacent rock or soil. This process is very slow and may take hundreds to thousands of years before a measurable increase is seen in the natural isotopic ratio. If site releases are the source of uranium being measured in groundwater, the U-234 to U-238 ratio is commonly closer to 1, which normally reflects FUSRAP-related, uranium-contaminated wastes and soils. This lower ratio occurs because not enough residence time has elapsed since the 1940's and 1950's for the alpha particle recoil effect to have significantly altered the contamination-derived ratio. An evaluation of NFSS-specific and regional groundwater data indicate that an isotopic ratio of 1.2 has been identified as a signature value to help distinguish natural groundwater, which may have a broad background range, from zones impacted by past releases. (authors)

  16. Laser separation of medical isotopes

    SciTech Connect (OSTI)

    Eerkens, J.W.; Puglishi, D.A.; Miller, W.H.

    1996-12-31

    There is an increasing demand for different separated isotopes as feed material for reactor and cyclotron-produced radioisotopes used by a fast-growing radiopharmaceutical industry. One new technology that may meet future demands for medical isotopes is molecular laser isotope separation (MLIS). This method was investigated for the enrichment of uranium in the 1970`s and 1980s by Los Alamos National Laboratory, Isotope Technologies, and others around the world. While South Africa and Japan have continued the development of MLIS for uranium and are testing pilot units, around 1985 the United States dropped the LANL MLIS program in favor of AVLIS (atomic vapor LIS), which uses electron-beam-heated uranium metal vapor. AVLIS appears difficult and expensive to apply to most isotopes of medical interest, however, whereas MLIS technology, which is based on cooled hexafluorides or other gaseous molecules, can be adapted more readily. The attraction of MLIS for radiopharmaceutical firms is that it allows them to operate their own dedicated separators for small-quantity productions of critical medical isotopes, rather than having to depend on large enrichment complexes run by governments, which are only optimal for large-quantity productions. At the University of Missouri, the authors are investigating LIS of molybdenum isotopes using MoF{sub 6}, which behaves in a way similar to UF{sub 6}, studied in the past.

  17. Stable isotope research pool inventory

    SciTech Connect (OSTI)

    Not Available

    1981-01-01

    This report contains a listing of electromagnetically separated stable isotopes which are available for distribution within the United States for non-destructive research use from the Oak Ridge National Laboratory on a loan basis. This inventory includes all samples of stable isotopes in the Materials Research Collection and does not designate whether a sample is out on loan or in reprocessing. For some of the high abundance naturally occurring isotopes, larger amounts can be made available; for example, Ca-40 and Fe-56.

  18. Stable isotope research pool inventory

    SciTech Connect (OSTI)

    Not Available

    1983-03-01

    This report contains a listing of electromagnetically separated stable isotopes which are available for distribution within the United States for non-destructive research use from the Oak Ridge National Laboratory on a loan basis. This inventory includes all samples of stable isotopes in the Materials Research Collection and does not designate whether a sample is out on loan or in reprocessing. For some of the high abundance naturally occurring isotopes, larger amounts can be made available; for example, Ca-40 and Fe-56.

  19. Compelling Research Opportunities using Isotopes

    SciTech Connect (OSTI)

    2009-04-23

    Isotopes are vital to the science and technology base of the US economy. Isotopes, both stable and radioactive, are essential tools in the growing science, technology, engineering, and health enterprises of the 21st century. The scientific discoveries and associated advances made as a result of the availability of isotopes today span widely from medicine to biology, physics, chemistry, and a broad range of applications in environmental and material sciences. Isotope issues have become crucial aspects of homeland security. Isotopes are utilized in new resource development, in energy from bio-fuels, petrochemical and nuclear fuels, in drug discovery, health care therapies and diagnostics, in nutrition, in agriculture, and in many other areas. The development and production of isotope products unavailable or difficult to get commercially have been most recently the responsibility of the Department of Energy's Nuclear Energy program. The President's FY09 Budget request proposed the transfer of the Isotope Production program to the Department of Energy's Office of Science in Nuclear Physics and to rename it the National Isotope Production and Application program (NIPA). The transfer has now taken place with the signing of the 2009 appropriations bill. In preparation for this, the Nuclear Science Advisory Committee (NSAC) was requested to establish a standing subcommittee, the NSAC Isotope Subcommittee (NSACI), to advise the DOE Office of Nuclear Physics. The request came in the form of two charges: one, on setting research priorities in the short term for the most compelling opportunities from the vast array of disciplines that develop and use isotopes and two, on making a long term strategic plan for the NIPA program. This is the final report to address charge 1. NSACI membership is comprised of experts from the diverse research communities, industry, production, and homeland security. NSACI discussed research opportunities divided into three areas: (1) medicine

  20. Laser separation of nitrogen isotopes by the IR+UV dissociation of ammonia molecules

    SciTech Connect (OSTI)

    Apatin, V M; Klimin, S A; Laptev, V B; Lokhman, V N; Ogurok, D D; Pigul'skii, S V; Ryabov, E A

    2008-08-31

    The separation of nitrogen isotopes is studied upon successive single-photon IR excitation and UV dissociation of ammonia molecules. The excitation selectivity was provided by tuning a CO{sub 2} laser to resonance with {sup 14}NH{sub 3} molecules [the 9R(30) laser line] or with {sup 15}NH{sub 3} molecules [the 9R(10) laser line]. Isotopic mixtures containing 4.8% and 0.37% (natural content) of the {sup 15}NH isotope were investigated. The dependences of the selectivity and the dissociation yield for each isotopic component on the buffer gas pressure (N{sub 2}, O{sub 2}, Ar) and the ammonia pressure were obtained. In the limit of low NH{sub 3} pressures (0.5-2 Torr), the dissociation selectivity {alpha}(15/14) for {sup 15}N was 17. The selectivity mechanism of the IR+UV dissociation is discussed and the outlook is considered for the development of the nitrogen isotope separation process based on this approach. (laser isotope separation)

  1. Tracing the transport of anthropogenic lead in the atmosphere and in soils using isotopic ratios

    SciTech Connect (OSTI)

    Erel, Y.; Veron, A.; Halicz, L.

    1997-11-01

    The isotopic composition of lead in aerosols and soils in Israel is used to characterize the sources of anthropogenic lead in the region, to ascertain the isotopic composition of natural, rock-derived lead in specific areas, and to determine rates of anthropogenic lead migration in soils. The isotopic composition of lead currently emitted from cars in Israel ({sup 206}Pb/{sup 207}Pb = 1.115 {+-} 2) is controlled by alkyl-lead produced in France and Germany. In addition to petrol-lead, two more sources of anthropogenic lead can be detected in sampled aerosols; the first one has low concentrations of lead ({approximately} ng/m{sup 3}) and {sup 206}Pb/{sup 207}Pb {approximately} 1.157, and is most likely lead, emitted in Turkey, that traveled across the eastern Mediterranean basin; the second type of aerosols contains a mixture of lead emitted in several countries including Turkey, Greece, and Ukraine ({sup 206}Pb/{sup 207}Pb value of 1.155-1.160; [Pb] {approximately}20-30 ng/m{sup 3}). Anthropogenic lead is more accessible for acid leaching than natural lead, therefore, it is more labile in the soil. The isotopic composition of lead in the acid-leached fraction of near-road soil profiles records the history of alkyl-lead emission in the country. Based on changes in the isotopic composition of lead with soil depth, it is estimated that anthropogenic lead migrates into the soil at approximately 0.5 cm/y. A soil profile from a relatively remote area is less contaminated by anthropogenic lead and displays a different distribution of lead isotopic values with depth. The isotopic composition of lead suggests that natural lead in soils developed on carbonate bedrock is derived from clays, either from the rock-residue (the clay fraction in the carbonate bedrock), or from airborne clay, but not from lead released from the carbonate fraction in the rock. 44 refs., 6 figs., 2 tabs.

  2. Apparatus and process for separating hydrogen isotopes

    DOE Patents [OSTI]

    Heung, Leung K; Sessions, Henry T; Xiao, Xin

    2013-06-25

    The apparatus and process for separating hydrogen isotopes is provided using dual columns, each column having an opposite hydrogen isotopic effect such that when a hydrogen isotope mixture feedstock is cycled between the two respective columns, two different hydrogen isotopes are separated from the feedstock.

  3. Method for laser induced isotope enrichment

    DOE Patents [OSTI]

    Pronko, Peter P.; Vanrompay, Paul A.; Zhang, Zhiyu

    2004-09-07

    Methods for separating isotopes or chemical species of an element and causing enrichment of a desired isotope or chemical species of an element utilizing laser ablation plasmas to modify or fabricate a material containing such isotopes or chemical species are provided. This invention may be used for a wide variety of materials which contain elements having different isotopes or chemical species.

  4. Simulation of mixed-host emitting layer based organic light emitting diodes

    SciTech Connect (OSTI)

    Riku, C.; Kee, Y. Y.; Ong, T. S.; Tou, T. Y.; Yap, S. S.

    2015-04-24

    ‘SimOLED’ simulator is used in this work to investigate the efficiency of the mixed-host organic light emitting devices (MH-OLEDs). Tris-(8-hydroxyquinoline) aluminum(3) (Alq{sub 3}) and N,N-diphenyl-N,N-Bis(3-methylphenyl)-1,1-diphenyl-4,4-diamine (TPD) are used as the electron transport layer (ETL) material and hole transport layer (HTL) material respectively, and the indium-doped tin oxide (ITO) and aluminum (Al) as anode and cathode. Three MH-OLEDs, A, B and C with the same structure of ITO / HTM (15 nm) / Mixed host (70 nm) / ETM (10 nm) /Al, are stimulated with ratios TPD:Alq{sub 3} of 3:5, 5:5, and 5:3 respectively. The Poole-Frenkel model for electron and hole mobilities is employed to compute the current density-applied voltage-luminance characteristics, distribution of the electric field, carrier concentrations and recombination rate.

  5. Raman scattering method and apparatus for measuring isotope ratios and isotopic abundances

    DOE Patents [OSTI]

    Harney, Robert C.; Bloom, Stewart D.

    1978-01-01

    Raman scattering is used to measure isotope ratios and/or isotopic abundances. A beam of quasi-monochromatic photons is directed onto the sample to be analyzed, and the resulting Raman-scattered photons are detected and counted for each isotopic species of interest. These photon counts are treated mathematically to yield the desired isotope ratios or isotopic abundances.

  6. Light-emitting block copolymers composition, process and use

    DOE Patents [OSTI]

    Ferraris, John P.; Gutierrez, Jose J.

    2006-11-14

    Generally, and in one form, the present invention is a composition of light-emitting block copolymer. In another form, the present invention is a process producing a light-emitting block copolymers that intends polymerizing a first di(halo-methyl) aromatic monomer compound in the presence of an anionic initiator and a base to form a polymer and contacting a second di(halo-methyl) aromatic monomer compound with the polymer to form a homopolymer or block copolymer wherein the block copolymer is a diblock, triblock, or star polymer. In yet another form, the present invention is an electroluminescent device comprising a light-emitting block copolymer, wherein the electroluminescent device is to be used in the manufacturing of optical and electrical devices.

  7. Flip-chip light emitting diode with resonant optical microcavity

    DOE Patents [OSTI]

    Gee, James M.; Bogart, Katherine H.A.; Fischer, Arthur J.

    2005-11-29

    A flip-chip light emitting diode with enhanced efficiency. The device structure employs a microcavity structure in a flip-chip configuration. The microcavity enhances the light emission in vertical modes, which are readily extracted from the device. Most of the rest of the light is emitted into waveguided lateral modes. Flip-chip configuration is advantageous for light emitting diodes (LEDs) grown on dielectric substrates (e.g., gallium nitride LEDs grown on sapphire substrates) in general due to better thermal dissipation and lower series resistance. Flip-chip configuration is advantageous for microcavity LEDs in particular because (a) one of the reflectors is a high-reflectivity metal ohmic contact that is already part of the flip-chip configuration, and (b) current conduction is only required through a single distributed Bragg reflector. Some of the waveguided lateral modes can also be extracted with angled sidewalls used for the interdigitated contacts in the flip-chip configuration.

  8. Oxycarbonitride phosphors and light emitting devices using the same

    DOE Patents [OSTI]

    Li, Yuanqiang; Romanelli, Michael Dennis; Tian, Yongchi

    2014-07-08

    Disclosed herein is a novel family of oxycarbonitride phosphor compositions and light emitting devices incorporating the same. Within the sextant system of M--Al--Si--O--N--C--Ln and quintuplet system of M--Si--O--N--C--Ln (M=alkaline earth element, Ln=rare earth element), the phosphors are composed of either one single crystalline phase or two crystalline phases with high chemical and thermal stability. In certain embodiments, the disclosed phosphor of silicon oxycarbonitrides emits green light at wavelength between 530-550 nm. In further embodiments, the disclosed phosphor compositions emit blue-green to yellow light in a wavelength range of 450-650 nm under near-UV and blue light excitation.

  9. Oxycarbonitride phosphors and light emitting devices using the same

    DOE Patents [OSTI]

    Li, Yuanqiang; Romanelli, Michael Dennis; Tian, Yongchi

    2013-10-08

    Disclosed herein is a novel family of oxycarbidonitride phosphor compositions and light emitting devices incorporating the same. Within the sextant system of M--Al--Si--O--N--C--Ln and quintuplet system of M--Si--O--N--C--Ln (M=alkaline earth element, Ln=rare earth element), the phosphors are composed of either one single crystalline phase or two crystalline phases with high chemical and thermal stability. In certain embodiments, the disclosed phosphor of silicon oxycarbidonitrides emits green light at wavelength between 530-550 nm. In further embodiments, the disclosed phosphor compositions emit blue-green to yellow light in a wavelength range of 450-650 nm under near-UV and blue light excitation.

  10. Close-packed array of light emitting devices

    DOE Patents [OSTI]

    Ivanov, Ilia N.; Simpson, John T.

    2013-04-09

    A close-packed array of light emitting diodes includes a nonconductive substrate having a plurality of elongate channels extending therethrough from a first side to a second side, where each of the elongate channels in at least a portion of the substrate includes a conductive rod therein. The conductive rods have a density over the substrate of at least about 1,000 rods per square centimeter and include first conductive rods and second conductive rods. The close-packed array further includes a plurality of light emitting diodes on the first side of the substrate, where each light emitting diode is in physical contact with at least one first conductive rod and in electrical contact with at least one second conductive rod.

  11. Light emitting ceramic device and method for fabricating the same

    DOE Patents [OSTI]

    Valentine, Paul; Edwards, Doreen D.; Walker Jr., William John; Slack, Lyle H.; Brown, Wayne Douglas; Osborne, Cathy; Norton, Michael; Begley, Richard

    2004-11-30

    A light-emitting ceramic based panel, hereafter termed "electroceramescent" panel, and alternative methods of fabrication for the same are claimed. The electroceramescent panel is formed on a substrate providing mechanical support as well as serving as the base electrode for the device. One or more semiconductive ceramic layers directly overlay the substrate, and electrical conductivity and ionic diffusion are controlled. Light emitting regions overlay the semiconductive ceramic layers, and said regions consist sequentially of a layer of a ceramic insulation layer and an electroluminescent layer, comprised of doped phosphors or the equivalent. One or more conductive top electrode layers having optically transmissive areas overlay the light emitting regions, and a multi-layered top barrier cover comprising one or more optically transmissive non-combustible insulation layers overlay said top electrode regions.

  12. Physics with isotopically controlled semiconductors

    SciTech Connect (OSTI)

    Haller, E. E.

    2010-07-15

    This paper is based on a tutorial presentation at the International Conference on Defects in Semiconductors (ICDS-25) held in Saint Petersburg, Russia in July 2009. The tutorial focused on a review of recent research involving isotopically controlled semiconductors. Studies with isotopically enriched semiconductor structures experienced a dramatic expansion at the end of the Cold War when significant quantities of enriched isotopes of elements forming semiconductors became available for worldwide collaborations. Isotopes of an element differ in nuclear mass, may have different nuclear spins and undergo different nuclear reactions. Among the latter, the capture of thermal neutrons which can lead to neutron transmutation doping, is the most prominent effect for semiconductors. Experimental and theoretical research exploiting the differences in all the properties has been conducted and will be illustrated with selected examples.

  13. Stable isotope research pool inventory

    SciTech Connect (OSTI)

    Not Available

    1985-02-01

    This report contains a listing of electromagnetically separated stable isotopes which are available at the Oak Ridge National Laboratory for distribution for non-destructive research use on a loan basis. This inventory includes all samples of stable isotopes in the Research Materials Collection and does not designate whether a sample is out on loan or is in reprocessing. For some of the high abundance naturally occurring isotopes, larger amounts can be made available; for example, /sup 40/Ca and /sup 56/Fe. All request for the loan of samples should be submitted with a summary of the purpose of the loan to: Isotope Distribution Office, Oak Ridge National Laboratory, P.O. Box X, Oak Ridge, Tennessee 37831. Requests from non-DOE contractors and from foreign institutions require DOE approval.

  14. Vertical-cavity surface-emitting laser device

    DOE Patents [OSTI]

    Hadley, G. Ronald; Lear, Kevin L.; Awyoung, Adelbert; Choquette, Kent D.

    1999-01-01

    A vertical-cavity surface-emitting laser device. The vertical-cavity surface-emitting laser (VCSEL) device comprises one or more VCSELs with each VCSEL having a mode-control region thereabout, with the mode-control region forming an optical cavity with an effective cavity length different from the effective cavity length within each VCSEL. Embodiments of the present invention can be formed as single VCSELs and as one- or two-dimensional arrays of VCSELs, with either an index-guided mode of operation or an index anti-guided mode of operation being defined by a sign of the difference in the two effective cavity lengths.

  15. Novel hybrid isotope separation scheme and apparatus

    DOE Patents [OSTI]

    Maya, Jakob

    1991-01-01

    A method of yielding selectively a desired enrichment in a specific isotope including the steps of inputting into a spinning chamber a gas from which the specific isotope is to be isolated, radiating the gas with frequencies characteristic of the absorption of a particular isotope of the atomic or molecular gas, thereby inducing a photoionization reaction of the desired isotope, and collecting the specific isotope ion by suitable ion collection means.

  16. Novel hybrid isotope separation scheme and apparatus

    DOE Patents [OSTI]

    Maya, J.

    1991-06-18

    A method is described for yielding selectively a desired enrichment in a specific isotope including the steps of inputting into a spinning chamber a gas from which the specific isotope is to be isolated, radiating the gas with frequencies characteristic of the absorption of a particular isotope of the atomic or molecular gas, thereby inducing a photoionization reaction of the desired isotope, and collecting the specific isotope ion by suitable ion collection means. 3 figures.

  17. [alpha]E-catenin is an autoinhibited molecule that coactivates...

    Office of Scientific and Technical Information (OSTI)

    alphaE-catenin is an autoinhibited molecule that coactivates vinculin Citation Details In-Document Search Title: alphaE-catenin is an autoinhibited molecule that coactivates ...

  18. Microscopic Study Of Alpha + N Bremsstrahlung From Effective...

    Office of Scientific and Technical Information (OSTI)

    Microscopic Study Of Alpha + N Bremsstrahlung From Effective And Realistic Inter-Nucleon Interactions Citation Details In-Document Search Title: Microscopic Study Of Alpha + N ...

  19. Microscopic Study Of Alpha + N Bremsstrahlung From Effective...

    Office of Scientific and Technical Information (OSTI)

    Of Alpha + N Bremsstrahlung From Effective And Realistic Inter-Nucleon Interactions Citation Details In-Document Search Title: Microscopic Study Of Alpha + N Bremsstrahlung ...

  20. Search For Hadronic Axions Emitted From The Sun

    SciTech Connect (OSTI)

    Ljubicic, A.; Kekez, D.; Krecak, Z.

    2007-10-26

    We made a search for hadronic axions, which could be emitted from the Sun in the axiobremsstrahlung process and absorbed in the HPGe detector by axioelectric effect. An upper limit on hadronic axion mass of 100 eV is obtained at the 95% confidence level.

  1. Photon extraction from nitride ultraviolet light-emitting devices

    DOE Patents [OSTI]

    Schowalter, Leo J; Chen, Jianfeng; Grandusky, James R

    2015-02-24

    In various embodiments, a rigid lens is attached to a light-emitting semiconductor die via a layer of encapsulant having a thickness insufficient to prevent propagation of thermal expansion mismatch-induced strain between the rigid lens and the semiconductor die.

  2. {alpha}-cluster structure and density waves in oblate nuclei...

    Office of Scientific and Technical Information (OSTI)

    BOSONS; CALCULATION METHODS; CARBON ISOTOPES; ELEMENTARY PARTICLES; EVEN-EVEN NUCLEI; FERMIONS; FUNCTIONS; HADRONS; ISOTOPES; KAONS; LIGHT NUCLEI; MATHEMATICAL MODELS; MATTER; ...

  3. Atomic line emission analyzer for hydrogen isotopes (Patent)...

    Office of Scientific and Technical Information (OSTI)

    Atomic line emission analyzer for hydrogen isotopes Title: Atomic line emission analyzer for hydrogen isotopes Apparatus for isotopic analysis of hydrogen comprises a low pressure ...

  4. Department of Energy's Isotope Development and Production for...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... The Isotope Program prices isotopes sold for medical and industrial applications to recover full cost. Isotopes sold for research and development are priced to recover direct costs ...

  5. Isotope production facility produces cancer-fighting actinium

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Cancer therapy gets a boost from new isotope Isotope production facility produces cancer-fighting actinium A new medical isotope project shows promise for rapidly producing major ...

  6. Isotope separation by photochromatography (Patent) | SciTech...

    Office of Scientific and Technical Information (OSTI)

    Patent: Isotope separation by photochromatography Citation Details In-Document Search Title: Isotope separation by photochromatography An isotope separation method which comprises ...

  7. Isotope specific resolution recovery image reconstruction in high resolution PET imaging

    SciTech Connect (OSTI)

    Kotasidis, Fotis A.; Angelis, Georgios I.; Anton-Rodriguez, Jose; Matthews, Julian C.; Reader, Andrew J.; Zaidi, Habib

    2014-05-15

    recovery image reconstruction. The benefits are expected to be more substantial for more energetic positron emitting isotopes such as Oxygen-15 and Rubidium-82.

  8. Tri Alpha Energy | Open Energy Information

    Open Energy Info (EERE)

    information indicates the company's goal is the commercialisation of plasma based nuclear fusion. References: Tri Alpha Energy1 This article is a stub. You can help OpenEI...

  9. Nuclear diagnostic for fast alpha particles

    DOE Patents [OSTI]

    Grisham, L.R.; Post, D.E. Jr.; Dawson, J.M.

    1983-11-23

    This invention relates generally to high energy confined plasmas and more particularly is directed to measuring the velocity distribution of confined energetic alpha particles resulting from deuterium-tritium fusion reactions in a confined energetic plasma.

  10. Alpha particles in effective field theory

    SciTech Connect (OSTI)

    Caniu, C.

    2014-11-11

    Using an effective field theory for alpha (?) particles at non-relativistic energies, we calculate the strong scattering amplitude modified by Coulomb corrections for a system of two ?s. For the strong interaction, we consider a momentum-dependent interaction which, in contrast to an energy dependent interaction alone [1], could be more useful in extending the theory to systems with more than two ? particles. We will present preliminary results of our EFT calculations for systems with two alpha particles.

  11. Preparation and properties of (R)-(-)-1-azabicyclo(2. 2. 2)oct-3-yl- (R)-(+)-alpha-hydroxy-alpha-(4-( sup 125 I)iodophenyl)-alpha-phenyl acetate and (R)-(-)-1-azabicyclo(2. 2. 2)oct-3-yl-(S)-(-)-alpha-hydroxy-alpha- (4-( sup 125 I)iodophenyl)-alpha-phenyl acetate as potential radiopharmaceuticals

    SciTech Connect (OSTI)

    Cohen, V.I.; Rzeszotarski, W.J.; Gibson, R.E.; Fan, L.H.; Reba, R.C. )

    1989-10-01

    rac-4-Nitrobenzilic acid was synthesized and resolved with quinidine and quinine to give the corresponding (R)- and (S)-salts. The resolved diastereomeric salts were converted to (R)- and (S)-4-nitrobenzilic acids and subsequent esterification gave their corresponding ethyl esters. Transesterification with (R)-(-)-3-quinuclidinol afforded (R)-(-)-1-azabicyclo(2.2.2)oct-3-yl-(R)-(+)-alpha-hydroxy-alpha- (4-nitrophenyl)-alpha-phenyl acetate and (R)-(-)-1-azabicyclo(2.2.2)oct-3-yl-(S)-(-)-alpha-hydroxy- alpha-(4-nitrophenyl)-alpha-phenyl acetate. After hydrogenation, the (R,R)- and (R,S)-amines were converted to the respective triazene derivatives. The triazene derivatives reacted with sodium ({sup 125}I)iodide to give (R)-(-)-1-azabicyclo(2.2.2)oct-3-yl-(R)-(+)- alpha-hydroxy-alpha-(4-({sup 125}I)iodophenyl)-alpha-phenyl acetate and (R)-(-)-1-azabicyclo(2.2.2)oct-3-yl-(S)-(-)-alpha-hydroxy- alpha-(4-(125I)iodophenyl)-alpha-phenyl acetate. The evaluation of their affinities to muscarinic acetylcholine receptors (MAcChR) shows that (R)-(-)-1-azabicyclo(2.2.2)oct-3-yl-(S)-(-)-alpha-hydroxy-alpha-(4- ({sup 125}I)iodophenyl)-alpha-phenyl acetate exhibits an affinity for the MAcChR from corpus striatum that is approximately threefold lower than that of (R)-(-)-1-azabicyclo(2.2.2)oct-3-yl-(R)-(+)-alpha-hydroxy-alpha-(4- ({sup 125}I)iodophenyl)-alpha-phenyl acetate.

  12. Structures of G [alpha [superscript i1

    SciTech Connect (OSTI)

    Johnston, Christopher A.; Willard, Francis S.; Jezyk, Mark R.; Fredericks, Zoey; Bodor, Erik T.; Jones, Miller B.; Blaesius, Rainer; Watts, Val J.; Harden, T. Kendall; Sondek, John; Ramer, J. Kevin; Siderovski, David P.

    2010-07-19

    Heterotrimeric G proteins are molecular switches that regulate numerous signaling pathways involved in cellular physiology. This characteristic is achieved by the adoption of two principal states: an inactive, GDP bound state and an active, GTP bound state. Under basal conditions, G proteins exist in the inactive, GDP bound state; thus, nucleotide exchange is crucial to the onset of signaling. Despite our understanding of G protein signaling pathways, the mechanism of nucleotide exchange remains elusive. We employed phage display technology to identify nucleotide state-dependent G{alpha} binding peptides. Herein, we report a GDP-selective G{alpha} binding peptide, KB-752, that enhances spontaneous nucleotide exchange of G{alpha}{sub i} subunits. Structural determination of the G{alpha}{sub i1}/peptide complex reveals unique changes in the G{alpha} switch regions predicted to enhance nucleotide exchange by creating a GDP dissociation route. Our results cast light onto a potential mechanism by which G{alpha} subunits adopt a conformation suitable for nucleotide exchange.

  13. Isotope specific arbitrary material sorter

    DOE Patents [OSTI]

    Barty, Christopher P.J.

    2015-12-08

    A laser-based mono-energetic gamma-ray source is used to provide a rapid and unique, isotope specific method for sorting materials. The objects to be sorted are passed on a conveyor in front of a MEGa-ray beam which has been tuned to the nuclear resonance fluorescence transition of the desired material. As the material containing the desired isotope traverses the beam, a reduction in the transmitted MEGa-ray beam occurs. Alternately, the laser-based mono-energetic gamma-ray source is used to provide non-destructive and non-intrusive, quantitative determination of the absolute amount of a specific isotope contained within pipe as part of a moving fluid or quasi-fluid material stream.

  14. Stable isotope research pool inventory

    SciTech Connect (OSTI)

    Not Available

    1986-08-01

    This report contains a listing of electromagnetically separated stable isotopes which are available at the Oak Ridge National Laboratory for distribution for nondestructive research use on a loan basis. This inventory includes all samples of stable isotopes in the Research Materials Collection and does not designate whether a sample is out on loan or is in reprocessing. For some of the high-abundance, naturally occurring isotopes, larger amounts can be made available; for example, Ca-40 and Fe-56. All requests for the loan of samples should be submitted with a summary of the purpose of the loan to: Iotope Distribution Office, Oak Ridge National Laboratory, P.O. Box X, Oak Ridge, Tennessee 37831. Requests from non-DOE contractors and from foreign institutions require DOE approval.

  15. Isotope geochronology of metamorphic processes

    SciTech Connect (OSTI)

    Ovchinnikov, L.N.; Voronovskiy, S.N.; Ovchinnikova, L.V.

    1986-05-01

    The long history of the earth and its crust is a history of uninterrupted and continuing transformation, making metamorphism the most common and most extensive geological process on this planet. Metamorphism has occurred in all epochs and is a factor in all endogenic processes: geodynamics, magmatism, and the action of intratelluric fluids. But it varies in scale, type, and mechanism, and is always combined with metasomatism - the chemical and mineral transformation of material. This paper discusses methodological principles of isotope dating, laws characterizing changes in indicator minerals, internal stability of isotopic systems, and interesting geological problems. 13 references.

  16. High extraction efficiency ultraviolet light-emitting diode

    DOE Patents [OSTI]

    Wierer, Jonathan; Montano, Ines; Allerman, Andrew A.

    2015-11-24

    Ultraviolet light-emitting diodes with tailored AlGaN quantum wells can achieve high extraction efficiency. For efficient bottom light extraction, parallel polarized light is preferred, because it propagates predominately perpendicular to the QW plane and into the typical and more efficient light escape cones. This is favored over perpendicular polarized light that propagates along the QW plane which requires multiple, lossy bounces before extraction. The thickness and carrier density of AlGaN QW layers have a strong influence on the valence subband structure, and the resulting optical polarization and light extraction of ultraviolet light-emitting diodes. At Al>0.3, thinner QW layers (<2.5 nm are preferred) result in light preferentially polarized parallel to the QW plane. Also, active regions consisting of six or more QWs, to reduce carrier density, and with thin barriers, to efficiently inject carriers in all the QWs, are preferred.

  17. Phosphorescent organic light emitting diodes with high efficiency and brightness

    DOE Patents [OSTI]

    Forrest, Stephen R; Zhang, Yifan

    2015-11-12

    An organic light emitting device including a) an anode; b) a cathode; and c) an emissive layer disposed between the anode and the cathode, the emissive layer comprising an organic host compound and a phosphorescent compound exhibiting a Stokes Shift overlap greater than 0.3 eV. The organic light emitting device may further include a hole transport layer disposed between the emissive layer and the anode; and an electron transport layer disposed between the emissive layer and the cathode. In some embodiments, the phosphorescent compound exhibits a phosphorescent lifetime of less than 10 .mu.s. In some embodiments, the concentration of the phosphorescent compound ranges from 0.5 wt. % to 10 wt. %.

  18. Vertical-cavity surface-emitting laser device

    DOE Patents [OSTI]

    Hadley, G.R.; Lear, K.L.; Awyoung, A.; Choquette, K.D.

    1999-05-11

    A vertical-cavity surface-emitting laser device is disclosed. The vertical-cavity surface-emitting laser (VCSEL) device comprises one or more VCSELs with each VCSEL having a mode-control region thereabout, with the mode-control region forming an optical cavity with an effective cavity length different from the effective cavity length within each VCSEL. Embodiments of the present invention can be formed as single VCSELs and as one- or two-dimensional arrays of VCSELs, with either an index-guided mode of operation or an index anti-guided mode of operation being defined by a sign of the difference in the two effective cavity lengths. 10 figs.

  19. Concave-hemisphere-patterned organic top-light emitting device

    DOE Patents [OSTI]

    Forrest, Stephen R; Slootsky, Michael; Lunt, Richard

    2014-01-21

    A first device is provided. The first device includes an organic light emitting device, which further comprises a first electrode, a second electrode, and an organic emissive layer disposed between the first and second electrode. Preferably, the second electrode is more transparent than the first electrode. The organic emissive layer has a first portion shaped to form an indentation in the direction of the first electrode, and a second portion shaped to form a protrusion in the direction of the second electrode. The first device may include a plurality of organic light emitting devices. The indentation may have a shape that is formed from a partial sphere, a partial cylinder, a pyramid, or a pyramid with a mesa, among others. The protrusions may be formed between adjoining indentations or between an indentation and a surface parallel to the substrate.

  20. Concave-hemisphere-patterned organic top-light emitting device

    DOE Patents [OSTI]

    Forrest, Stephen R.; Slootsky, Michael; Lunt, Richard

    2015-06-09

    A first device is provided. The first device includes an organic light emitting device, which further comprises a first electrode, a second electrode, and an organic emissive layer disposed between the first and second electrode. Preferably, the second electrode is more transparent than the first electrode. The organic emissive layer has a first portion shaped to form an indentation in the direction of the first electrode, and a second portion shaped to form a protrusion in the direction of the second electrode. The first device may include a plurality of organic light emitting devices. The indentation may have a shape that is formed from a partial sphere, a partial cylinder, a pyramid, or a pyramid with a mesa, among others. The protrusions may be formed between adjoining indentations or between an indentation and a surface parallel to the substrate.

  1. Organic light-emitting diodes from homoleptic square planar complexes

    DOE Patents [OSTI]

    Omary, Mohammad A

    2013-11-12

    Homoleptic square planar complexes [M(N.LAMBDA.N).sub.2], wherein two identical N.LAMBDA.N bidentate anionic ligands are coordinated to the M(II) metal center, including bidentate square planar complexes of triazolates, possess optical and electrical properties that make them useful for a wide variety of optical and electrical devices and applications. In particular, the complexes are useful for obtaining white or monochromatic organic light-emitting diodes ("OLEDs"). Improved white organic light emitting diode ("WOLED") designs have improved efficacy and/or color stability at high brightness in single- or two-emitter white or monochrome OLEDs that utilize homoleptic square planar complexes, including bis[3,5-bis(2-pyridyl)-1,2,4-triazolato]platinum(II) ("Pt(ptp).sub.2").

  2. Online Catalog of Isotope Products from DOE's National Isotope Development Center

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    The National Isotope Development Center (NIDC) interfaces with the User Community and manages the coordination of isotope production across the facilities and business operations involved in the production, sale, and distribution of isotopes. A virtual center, the NIDC is funded by the Isotope Development and Production for Research and Applications (IDPRA) subprogram of the Office of Nuclear Physics in the U.S. Department of Energy Office of Science. The Isotope subprogram supports the production, and the development of production techniques of radioactive and stable isotopes that are in short supply for research and applications. Isotopes are high-priority commodities of strategic importance for the Nation and are essential for energy, medical, and national security applications and for basic research; a goal of the program is to make critical isotopes more readily available to meet domestic U.S. needs. This subprogram is steward of the Isotope Production Facility (IPF) at Los Alamos National Laboratory (LANL), the Brookhaven Linear Isotope Producer (BLIP) facility at BNL, and hot cell facilities for processing isotopes at ORNL, BNL and LANL. The subprogram also coordinates and supports isotope production at a suite of university, national laboratory, and commercial accelerator and reactor facilities throughout the Nation to promote a reliable supply of domestic isotopes. The National Isotope Development Center (NIDC) at ORNL coordinates isotope production across the many facilities and manages the business operations of the sale and distribution of isotopes.

  3. Science with Beams of Radioactive Isotopes

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Pacifichem 2015 Pacifichem 2015 The International Chemical Congress of Pacific Basin Societies Science with Beams of Radioactive Isotopes (# 340) Honolulu, Hawaii, USA December 15-20, 2015 Science with Beams of Radioactive Isotopes (# 340) All of the elements that make up the periodic chart have been created from nuclear reactions. Many of the stable nuclei in the universe are daughters of unstable isotopes, and their true origin lies in the stellar reactions of these radioactive isotopes. Thus

  4. Isotopes for cancer and cardiac care

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Isotopes for cancer Isotopes for cancer and cardiac care Eva Birnbaum is interviewed on KSFR radio on the Lab's Isotope Program February 4, 2016 hot cell facility A worker uses remote manipulator arms to handle a highly radioactive target inside the Lab's radiochemistry hot cell facility. Isotopes from Los Alamos are used for the diagnosis of cardiac disease, for the calibration of PET scanners which in turn diagnose cancer, neurological disease, inflammatory diseases, trauma, and other

  5. Isotope Production in Light of Increasing Demand

    SciTech Connect (OSTI)

    Patton, B.

    2004-10-05

    This presentation is a part of the panel discussion on isotope production in light of increasing demand.

  6. Adoption of Light-Emitting Diodes in Common Lighting Applications

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Adoption of Light-Emitting Diodes in Common Lighting Applications Prepared for the U.S. Department of Energy Solid-State Lighting Program July 2015 Prepared by Navigant This page intentionally left blank i | P a g e Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government, nor any agency thereof, nor any of their employees, nor any of their contractors, subcontractors, or their employees, makes any

  7. Wide Area Thermal Processing of Light Emitting Materials

    SciTech Connect (OSTI)

    Duty, Chad E; Joshi, Pooran C; Jellison Jr, Gerald Earle; Angelini, Joseph Attilio; Sabau, Adrian S

    2011-10-01

    Laboratory laser materials synthesis of wide bandgap materials has been successfully used to create white light emitting materials (LEMs). This technology development has progressed to the exploration on design and construction of apparatus for wide area doping and phase transformation of wide bandgap material substrates. The objective of this proposal is to develop concepts for wide area doping and phase transformation based on AppliCote Associates, LLC laser technology and ORNL high density pulsed plasma arc technology.

  8. Organic light emitting device having multiple separate emissive layers

    DOE Patents [OSTI]

    Forrest, Stephen R. (Ann Arbor, MI)

    2012-03-27

    An organic light emitting device having multiple separate emissive layers is provided. Each emissive layer may define an exciton formation region, allowing exciton formation to occur across the entire emissive region. By aligning the energy levels of each emissive layer with the adjacent emissive layers, exciton formation in each layer may be improved. Devices incorporating multiple emissive layers with multiple exciton formation regions may exhibit improved performance, including internal quantum efficiencies of up to 100%.

  9. Laterally injected light-emitting diode and laser diode

    DOE Patents [OSTI]

    Miller, Mary A.; Crawford, Mary H.; Allerman, Andrew A.

    2015-06-16

    A p-type superlattice is used to laterally inject holes into an III-nitride multiple quantum well active layer, enabling efficient light extraction from the active area. Laterally-injected light-emitting diodes and laser diodes can enable brighter, more efficient devices that impact a wide range of wavelengths and applications. For UV wavelengths, applications include fluorescence-based biological sensing, epoxy curing, and water purification. For visible devices, applications include solid state lighting and projection systems.

  10. Electrically injected visible vertical cavity surface emitting laser diodes

    DOE Patents [OSTI]

    Schneider, R.P.; Lott, J.A.

    1994-09-27

    Visible laser light output from an electrically injected vertical cavity surface emitting laser (VSCEL) diode is enabled by the addition of phase-matching spacer layers on either side of the active region to form the optical cavity. The spacer layers comprise InAlP which act as charge carrier confinement means. Distributed Bragg reflector layers are formed on either side of the optical cavity to act as mirrors. 5 figs.

  11. Electrically injected visible vertical cavity surface emitting laser diodes

    DOE Patents [OSTI]

    Schneider, Richard P.; Lott, James A.

    1994-01-01

    Visible laser light output from an electrically injected vertical cavity surface emitting laser (VSCEL) diode is enabled by the addition of phase-matching spacer layers on either side of the active region to form the optical cavity. The spacer layers comprise InAlP which act as charge carrier confinement means. Distributed Bragg reflector layers are formed on either side of the optical cavity to act as mirrors.

  12. Alpha Channeling in Rotating Plasma with Stationary Waves

    SciTech Connect (OSTI)

    A. Fetterman and N.J. Fisch

    2010-02-15

    An extension of the alpha channeling effect to supersonically rotating mirrors shows that the rotation itself can be driven using alpha particle energy. Alpha channeling uses radiofrequency waves to remove alpha particles collisionlessly at low energy. We show that stationary magnetic fields with high n? can be used for this purpose, and simulations show that a large fraction of the alpha energy can be converted to rotation energy.

  13. Observable form of pulses emitted from relativistic collapsing objects

    SciTech Connect (OSTI)

    Frolov, Valeri P.; Lee, Hyun Kyu

    2005-02-15

    In this work, we discuss observable characteristics of the radiation emitted from a surface of a collapsing object. We study a simplified model in which a radiation of massless particles has a sharp in time profile, and it happens at the surface at the same moment of comoving time. Since the radiating surface has finite size the observed radiation will occur during some finite time. Its redshift and bending angle are affected by the strong gravitational field. We obtain a simple expression for the observed flux of the radiation as a function of time. To find an explicit expression for the flux we develop an analytical approximation for the bending angle and time delay for null rays emitted by a collapsing surface. In the case of the bending angle this approximation is an improved version of the earlier proposed Beloborodov-Leahy-approximation. For rays emitted at R>2R{sub g} the accuracy of the proposed improved approximations for the bending angle and time delay is of order (or less) than 2%-3%. By using this approximation we obtain an approximate analytical expression for the observed flux and study its properties.

  14. Observable Form of Pulses Emitted From Relativistic Collapsing Objects

    SciTech Connect (OSTI)

    Frolov, V.

    2005-01-28

    In this work, we discuss observable characteristics of the radiation emitted from a surface of a collapsing object. We study a simplified model in which a radiation of massless particles has a sharp in time profile and it happens at the surface at the same moment of comoving time. Since the radiating surface has finite size the observed radiation will occur during some finite time. Its redshift and bending angle are affected by the strong gravitational field. We obtain a simple expression for the observed flux of the radiation as a function of time. To find an explicit expression for the flux we develop an analytical approximation for the bending angle and time delay for null rays emitted by a collapsing surface. In the case of the bending angle this approximation is an improved version of the earlier proposed Beloborodov-Leahy-approximation. For rays emitted at R > 2R{sub g} the accuracy of the proposed improved approximations for the bending angle and time delay is of order (or less) than 2-3%. By using this approximation we obtain an approximate analytical expression for the observed flux and study its properties.

  15. Double Beta Decay in Xenon-136: Measuring the Neutrino-Emitting...

    Office of Scientific and Technical Information (OSTI)

    Double Beta Decay in Xenon-136: Measuring the Neutrino-Emitting Mode and Searching for Majoron-Emitting Modes Citation Details In-Document Search Title: Double Beta Decay in...

  16. High-Efficiency and Stable White Organic Light-Emitting Diode...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Efficiency and Stable White Organic Light-Emitting Diode Using a Single Emitter High-Efficiency and Stable White Organic Light-Emitting Diode Using a Single Emitter Lead Performer: ...

  17. Materials and architectures for efficient harvesting of singlet and triplet excitons for white light emitting OLEDs

    DOE Patents [OSTI]

    Thompson, Mark E; Forrest, Stephen

    2015-02-03

    The present invention relates to organic light emitting devices (OLEDs), and more specifically to OLEDS that emit light using a combination of fluorescent emitters and phosphorescent emitters for the efficient utilization of all of the electrically generated excitons.

  18. Development of bottom-emitting 1300 nm vertical-cavity surface...

    Office of Scientific and Technical Information (OSTI)

    Title: Development of bottom-emitting 1300 nm vertical-cavity surface-emitting lasers. No abstract prepared. Authors: Fish, M. A. 1 ; Serkland, Darwin Keith ; Guilfoyle, Peter S. ...

  19. Thin planar package for cooling an array of edge-emitting laser...

    Office of Scientific and Technical Information (OSTI)

    Thin planar package for cooling an array of edge-emitting laser diodes Title: Thin planar package for cooling an array of edge-emitting laser diodes A laser diode array is ...

  20. Isotope Cancer Treatment Research at LANL

    ScienceCinema (OSTI)

    Weidner, John; Nortier, Meiring

    2014-06-02

    Los Alamos National Laboratory has produced medical isotopes for diagnostic and imaging purposes for more than 30 years. Now LANL researchers have branched out into isotope cancer treatment studies. New results show that an accelerator-based approach can produce clinical trial quantities of actinium-225, an isotope that has promise as a way to kill tumors without damaging surrounding healthy cells.

  1. Isotope Cancer Treatment Research at LANL

    SciTech Connect (OSTI)

    Weidner, John; Nortier, Meiring

    2012-04-11

    Los Alamos National Laboratory has produced medical isotopes for diagnostic and imaging purposes for more than 30 years. Now LANL researchers have branched out into isotope cancer treatment studies. New results show that an accelerator-based approach can produce clinical trial quantities of actinium-225, an isotope that has promise as a way to kill tumors without damaging surrounding healthy cells.

  2. Dry phase reactor for generating medical isotopes

    DOE Patents [OSTI]

    Mackie, Thomas Rockwell; Heltemes, Thad Alexander

    2016-05-03

    An apparatus for generating medical isotopes provides for the irradiation of dry-phase, granular uranium compounds which are then dissolved in a solvent for separation of the medical isotope from the irradiated compound. Once the medical isotope is removed, the dissolved compound may be reconstituted in dry granular form for repeated irradiation.

  3. Highly efficient inverted top emitting organic light emitting diodes using a transparent top electrode with color stability on viewing angle

    SciTech Connect (OSTI)

    Kim, Jung-Bum; Lee, Jeong-Hwan; Moon, Chang-Ki; Kim, Jang-Joo, E-mail: jjkim@snu.ac.kr [Department of Materials Science and Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of)

    2014-02-17

    We report a highly efficient phosphorescent green inverted top emitting organic light emitting diode with excellent color stability by using the 1,4,5,8,9,11-hexaazatriphenylene-hexacarbonitrile/indium zinc oxide top electrode and bis(2-phenylpyridine)iridium(III) acetylacetonate as the emitter in an exciplex forming co-host system. The device shows a high external quantum efficiency of 23.4% at 1000?cd/m{sup 2} corresponding to a current efficiency of 110?cd/A, low efficiency roll-off with 21% at 10?000?cd/m{sup 2} and low turn on voltage of 2.4?V. Especially, the device showed very small color change with the variation of ?x?=?0.02, ?y?=?0.02 in the CIE 1931 coordinates as the viewing angle changes from 0 to 60. The performance of the device is superior to that of the metal/metal cavity structured device.

  4. High performance flexible top-emitting warm-white organic light-emitting devices and chromaticity shift mechanism

    SciTech Connect (OSTI)

    Shi, Hongying; Deng, Lingling; Chen, Shufen E-mail: wei-huang@njupt.edu.cn; Xu, Ying; Zhao, Xiaofei; Cheng, Fan; Huang, Wei E-mail: wei-huang@njupt.edu.cn; Jiangsu-Singapore Joint Research Center for Organic/Bio- Electronics and Information Displays and Institute of Advanced Materials, Nanjing University of Technology, Nanjing 211816

    2014-04-15

    Flexible warm-white top-emitting organic light-emitting devices (TEOLEDs) are fabricated onto PET substrates with a simple semi-transparent cathode Sm/Ag and two-color phosphors respectively doped into a single host material TCTA. By adjusting the relative position of the orange-red EML sandwiched between the blue emitting layers, the optimized device exhibits the highest power/current efficiency of 8.07 lm/W and near 13 cd/A, with a correlated color temperature (CCT) of 4105 K and a color rendering index (CRI) of 70. In addition, a moderate chromaticity variation of (-0.025, +0.008) around warm white illumination coordinates (0.45, 0.44) is obtained over a large luminance range of 1000 to 10000 cd/m{sup 2}. The emission mechanism is discussed via delta-doping method and single-carrier device, which is summarized that the carrier trapping, the exciton quenching, the mobility change and the recombination zone alteration are negative to color stability while the energy transfer process and the blue/red/blue sandwiched structure are contributed to the color stability in our flexible white TEOLEDs.

  5. New localized/delocalized emitting state of Eu2+ in orange-emitting hexagonal EuAl2O4

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Liu, Feng; Meltzer, Richard S.; Li, Xufan; Budai, John D.; Chen, Yu -Sheng; Pan, Zhengwei

    2014-11-18

    Eu2+-activated phosphors are being widely used in illuminations and displays. Some of these phosphors feature an extremely broad and red-shifted Eu2+ emission band; however, convincing explanation of this phenomenon is lacking. Here we report a new localized/delocalized emitting state of Eu2+ ions in a new hexagonal EuAl2O4 phosphor whose Eu2+ luminescence exhibits a very large bandwidth and an extremely large Stokes shift. At 77 K, two luminescent sites responsible for 550 nm and 645 nm broadband emissions are recognized, while at room temperature only the 645 nm emission band emits. The 645 nm emission exhibits a typical radiative lifetime ofmore » 1.27 μs and an unusually large Stokes shift of 0.92 eV. We identify the 645 nm emission as originating from a new type of emitting state whose composition is predominantly that of localized 4f65d character but which also contains a complementary component with delocalized conduction-band-like character. This investigation gives new insights into a unique type of Eu2+ luminescence in solids whose emission exhibits both a very large bandwidth and an extremely large Stokes shift.« less

  6. The Multi-Isotope Process (MIP) Monitor Project: FY13 Final Report

    SciTech Connect (OSTI)

    Meier, David E.; Coble, Jamie B.; Jordan, David V.; Mcdonald, Luther W.; Forrester, Joel B.; Schwantes, Jon M.; Unlu, Kenan; Landsberger, Sheldon; Bender, Sarah; Dayman, Kenneth J.; Reilly, Dallas D.

    2013-09-01

    The Multi-Isotope Process (MIP) Monitor provides an efficient approach to monitoring the process conditions in reprocessing facilities in support of the goal of “… (minimization of) the risks of nuclear proliferation and terrorism.” The MIP Monitor measures the distribution of the radioactive isotopes in product and waste streams of a nuclear reprocessing facility. These isotopes are monitored online by gamma spectrometry and compared, in near-real-time, to spectral patterns representing “normal” process conditions using multivariate analysis and pattern recognition algorithms. The combination of multivariate analysis and gamma spectroscopy allows us to detect small changes in the gamma spectrum, which may indicate changes in process conditions. By targeting multiple gamma-emitting indicator isotopes, the MIP Monitor approach is compatible with the use of small, portable, relatively high-resolution gamma detectors that may be easily deployed throughout an existing facility. The automated multivariate analysis can provide a level of data obscurity, giving a built-in information barrier to protect sensitive or proprietary operational data. Proof-of-concept simulations and experiments have been performed in previous years to demonstrate the validity of this tool in a laboratory setting for systems representing aqueous reprocessing facilities. However, pyroprocessing is emerging as an alternative to aqueous reprocessing techniques.

  7. Synthesis of peptide .alpha.-thioesters

    DOE Patents [OSTI]

    Camarero, Julio A.; Mitchell, Alexander R.; De Yoreo, James J.

    2008-08-19

    Disclosed herein is a new method for the solid phase peptide synthesis (SPPS) of C-terminal peptide .alpha. thioesters using Fmoc/t-Bu chemistry. This method is based on the use of an aryl hydrazine linker, which is totally stable to conditions required for Fmoc-SPPS. When the peptide synthesis has been completed, activation of the linker is achieved by mild oxidation. The oxidation step converts the acyl-hydrazine group into a highly reactive acyl-diazene intermediate which reacts with an .alpha.-amino acid alkylthioester (H-AA-SR) to yield the corresponding peptide .alpha.-thioester in good yield. A variety of peptide thioesters, cyclic peptides and a fully functional Src homology 3 (SH3) protein domain have been successfully prepared.

  8. Nuclear diagnostic for fast alpha particles

    DOE Patents [OSTI]

    Grisham, Larry R.; Post Jr., Douglass E.; Dawson, John M.

    1986-06-03

    Measurement of the velocity distribution of confined energetic alpha particles resulting from deuterium-tritium fusion reactions in a magnetically contained plasma is provided. The fusion plasma is seeded with energetic boron neutrals for producing, by means of the reaction .sup.10 B (.alpha.,n) .sup.13 N reaction, radioactive nitrogen nuclei which are then collected by a probe. The radioactivity of the probe is then measured by conventional techniques in determining the energy distribution of the alpha particles in the plasma. In a preferred embodiment, diborane gas (B.sub.2 H.sub.6) is the source of the boron neutrals to produce .sup.13 N which decays almost exclusively by positron emission with a convenient half-life of 10 minutes.

  9. Nuclear diagnostic for fast alpha particles

    DOE Patents [OSTI]

    Grisham, Larry R.; Post, Jr., Douglass E.; Dawson, John M.

    1986-01-01

    Measurement of the velocity distribution of confined energetic alpha particles resulting from deuterium-tritium fusion reactions in a magnetically contained plasma is provided. The fusion plasma is seeded with energetic boron neutrals for producing, by means of the reaction .sup.10 B (.alpha.,n) .sup.13 N reaction, radioactive nitrogen nuclei which are then collected by a probe. The radioactivity of the probe is then measured by conventional techniques in determining the energy distribution of the alpha particles in the plasma. In a preferred embodiment, diborane gas (B.sub.2 H.sub.6) is the source of the boron neutrals to produce .sup.13 N which decays almost exclusively by positron emission with a convenient half-life of 10 minutes.

  10. Alternating current long range alpha particle detector

    DOE Patents [OSTI]

    MacArthur, D.W.; McAtee, J.L.

    1993-02-16

    An alpha particle detector, utilizing alternating currents, which is capable of detecting alpha particles from distinct sources. The use of alternating currents allows use of simpler ac circuits which, in turn, are not susceptible to dc error components. It also allows the benefit of gas gain, if desired. In the invention, a voltage source creates an electric field between two conductive grids, and between the grids and a conductive enclosure. Air containing air ions created by collision with alpha particles is drawn into the enclosure and detected. In some embodiments, the air flow into the enclosure is interrupted, creating an alternating flow of ions. In another embodiment, a modulated voltage is applied to the grid, also modulating the detection of ions.

  11. Alternating current long range alpha particle detector

    DOE Patents [OSTI]

    MacArthur, Duncan W.; McAtee, James L.

    1993-01-01

    An alpha particle detector, utilizing alternating currents, whcih is capable of detecting alpha particles from distinct sources. The use of alternating currents allows use of simpler ac circuits which, in turn, are not susceptible to dc error components. It also allows the benefit of gas gain, if desired. In the invention, a voltage source creates an electric field between two conductive grids, and between the grids and a conductive enclosure. Air containing air ions created by collision with alpha particles is drawn into the enclosure and detected. In some embodiments, the air flow into the enclosure is interrupted, creating an alternating flow of ions. In another embodiment, a modulated voltage is applied to the grid, also modulating the detection of ions.

  12. Performance of an Alpha-IPEM.

    SciTech Connect (OSTI)

    Doyle, Barney Lee; McDaniel, Floyd Del; Rossi, Paolo; Auzelyte, Vaida; Mellon, Michael

    2005-07-01

    The ion photon emission microscope, or IPEM, is the first device that allows scientists to microscopically study the effects of single ions in air on semiconductors, microchips and even biological cells without having to focus the beam. Reported here is a prototype, the size of a conventional optical microscope, developed at Sandia. The alpha-IPEM, that employs alpha particles from a radioactive source, represents the first example of IBA imaging without an accelerator. The IPEM resolution is currently limited to 10 {micro}m, but we also report a gridded-phosphor approach that could improve this resolution to that of the optical microscope, or {approx} 1 {micro}m. Finally, we propose that a simple adaptation of the alpha-IPEM could be the only way to maintain the high utility of radiation effects microscopy into the future.

  13. Isotope hydrology of catchment basins: lithogenic and cosmogenic isotopic systems

    SciTech Connect (OSTI)

    Nimz, G. J., LLNL

    1998-06-01

    A variety of physical processes affect solute concentrations within catchment waters. The isotopic compositions of the solutes can indicate which processes have determined the observed concentrations. These processes together constitute the physical history of the water. Many solutes in natural waters are derived from the interaction between the water and the rock and/or soil within the system - these are termed `lithogenic` solutes. The isotopic compositions of these solutes provide information regarding rock-water interactions. Many other solutes have their isotopic compositions determined both within and outside of the catchment - i.e., in addition to being derived from catchment rock and soil, they are solutes that are also transported into the catchment. Important members of this group include solutes that have isotopic compositions produced by atomic particle interactions with other nuclides. The source of the atomic particles can be cosmic radiation (producing `cosmogenic` nuclides in the atmosphere and land surface), anthropogenic nuclear reactions (producing `thermonuclear` nuclides), or radioactive and fission decay of naturally-occurring elements, principally {sup 238}U (producing `in-situ` lithogenic nuclides in the deep subsurface). Current language usage often combines all of the atomic particle-produced nuclides under the heading `cosmogenic nuclides`, and for simplicity we will often follow that usage here, although always indicating which variety is being discussed. This paper addresses the processes that affect the lithogenic and cosmogenic solute concentrations in catchment waters, and how the isotopic compositions of the solutes can be used in integrative ways to identify these processes, thereby revealing the physical history of the water within a catchment system. The concept of a `system` is important in catchment hydrology. A catchment is the smallest landscape unit that can both participate in all of the aspects of the hydrologic cycle and

  14. Fan-less long range alpha detector

    DOE Patents [OSTI]

    MacArthur, D.W.; Bounds, J.A.

    1994-05-10

    A fan-less long range alpha detector is disclosed which operates by using an electrical field between a signal plane and the surface or substance to be monitored for air ions created by collisions with alpha radiation. Without a fan, the detector can operate without the possibility of spreading dust and potential contamination into the atmosphere. A guard plane between the signal plane and the electrically conductive enclosure and maintained at the same voltage as the signal plane, reduces leakage currents. The detector can easily monitor soil, or other solid or liquid surfaces. 2 figures.

  15. Fan-less long range alpha detector

    DOE Patents [OSTI]

    MacArthur, Duncan W.; Bounds, John A.

    1994-01-01

    A fan-less long range alpha detector which operates by using an electrical field between a signal plane and the surface or substance to be monitored for air ions created by collisions with alpha radiation. Without a fan, the detector can operate without the possibility of spreading dust and potential contamination into the atmosphere. A guard plane between the signal plane and the electrically conductive enclosure and maintained at the same voltage as the signal plane, reduces leakage currents. The detector can easily monitor soil, or other solid or liquid surfaces.

  16. Measuring SNM Isotopic Distributions using FRAM

    SciTech Connect (OSTI)

    Geist, William H.

    2015-12-02

    The first group of slides provides background information on the isotopic composition of plutonium. It is shown that 240Pu is the critical isotope in neutron coincidence/multiplicity counting. Next, response function analysis to determine isotopic composition is discussed. The isotopic composition can be determined by measuring the net peak counts from each isotope and then taking the ratio of the counts for each isotope relative to the total counts for the element. Then FRAM (Fixed energy Response function Analysis with Multiple efficiencies) is explained. FRAM can control data acquisition, automatically analyze newly acquired data, analyze previously acquired data, provide information on the quality of the analysis, and facilitate analysis in unusual situations (non-standard energy calibrations, gamma rays from non-SNM isotopes, poor spectra (within limits)).

  17. Laser ablation molecular isotopic spectrometry of carbon isotopes

    SciTech Connect (OSTI)

    Bol'shakov, Alexander A.; Jain, Jinesh; Russo, Richard E.; McIntyre, Dustin; Mao, Xianglei

    2015-08-28

    Quantitative determination of carbon isotopes using Laser Ablation Molecular Isotopic Spectrometry (LAMIS) is described. Optical emission of diatomic molecules CN and C2 is used in these measurements. Two quantification approaches are presented:empirical calibration of spectra using a set of reference standards and numerical fitting of a simulated spectrum to the experimental one. Formation mechanisms of C2 and CN in laser ablation plasma are briefly reviewed to provide insights for implementation of LAMIS measurements. A simulated spectrum of the 12C2 Swan system was synthesized using four constituents within 473.5–476.5 nm. Simulation included three branches of 12C2 (1-0), branches R(0-0) and R(1-1), and branch P(9-8) of 12C2. Spectral positions of the tail lines in R(0-0) and R(1-1) were experimentally measured, since they were not accurately known before. The Swan band (1-0) of the isotopologue 13C12C was also simulated. Fitting to the experimental spectrumyielded the ratio 13C/12C = 1.08% in a good agreement with measurements by isotope ratio mass spectrometry. LAMIS promises to be useful in coal, oil and shale exploration, carbon sequestration monitoring, and agronomy studies

  18. Recipient luminophoric mediums having narrow spectrum luminescent materials and related semiconductor light emitting devices and methods

    DOE Patents [OSTI]

    LeToquin, Ronan P; Tong, Tao; Glass, Robert C

    2014-12-30

    Light emitting devices include a light emitting diode ("LED") and a recipient luminophoric medium that is configured to down-convert at least some of the light emitted by the LED. In some embodiments, the recipient luminophoric medium includes a first broad-spectrum luminescent material and a narrow-spectrum luminescent material. The broad-spectrum luminescent material may down-convert radiation emitted by the LED to radiation having a peak wavelength in the red color range. The narrow-spectrum luminescent material may also down-convert radiation emitted by the LED into the cyan, green or red color range.

  19. Light collection optics for measuring flux and spectrum from light-emitting devices

    DOE Patents [OSTI]

    McCord, Mark A.; DiRegolo, Joseph A.; Gluszczak, Michael R.

    2016-05-24

    Systems and methods for accurately measuring the luminous flux and color (spectra) from light-emitting devices are disclosed. An integrating sphere may be utilized to directly receive a first portion of light emitted by a light-emitting device through an opening defined on the integrating sphere. A light collector may be utilized to collect a second portion of light emitted by the light-emitting device and direct the second portion of light into the integrating sphere through the opening defined on the integrating sphere. A spectrometer may be utilized to measure at least one property of the first portion and the second portion of light received by the integrating sphere.

  20. Benchmark of SCALE (SAS2H) isotopic predictions of depletion analyses for San Onofre PWR MOX fuel

    SciTech Connect (OSTI)

    Hermann, O.W.

    2000-02-01

    The isotopic composition of mixed-oxide (MOX) fuel, fabricated with both uranium and plutonium, after discharge from reactors is of significant interest to the Fissile Materials Disposition Program. The validation of the SCALE (SAS2H) depletion code for use in the prediction of isotopic compositions of MOX fuel, similar to previous validation studies on uranium-only fueled reactors, has corresponding significance. The EEI-Westinghouse Plutonium Recycle Demonstration Program examined the use of MOX fuel in the San Onofre PWR, Unit 1, during cycles 2 and 3. Isotopic analyses of the MOX spent fuel were conducted on 13 actinides and {sup 148}Nd by either mass or alpha spectrometry. Six fuel pellet samples were taken from four different fuel pins of an irradiated MOX assembly. The measured actinide inventories from those samples has been used to benchmark SAS2H for MOX fuel applications. The average percentage differences in the code results compared with the measurement were {minus}0.9% for {sup 235}U and 5.2% for {sup 239}Pu. The differences for most of the isotopes were significantly larger than in the cases for uranium-only fueled reactors. In general, comparisons of code results with alpha spectrometer data had extreme differences, although the differences in the calculations compared with mass spectrometer analyses were not extremely larger than that of uranium-only fueled reactors. This benchmark study should be useful in estimating uncertainties of inventory, criticality and dose calculations of MOX spent fuel.

  1. Solid-state radiation-emitting compositions and devices

    DOE Patents [OSTI]

    Ashley, Carol S.; Brinker, C. Jeffrey; Reed, Scott; Walko, Robert J.

    1992-01-01

    The invention relates to a composition for the volumetric generation of radiation, wherein a first substance functions as a source of exciting radiation, and a second substance interacts with the exciting radiation to provide a second radiation. The compositions comprise a porous substrate which is loaded with: a source of exciting radiation, a component capable of emitting radiation upon interaction with the exciting radiation, or both. Preferably, the composition is an aerogel substrate loaded with both a source of exciting radiation, such as tritium, and a component capable of interacting with the exciting radiation, e.g., a phosphor, to produce radiation of a second energy.

  2. Solid-state radiation-emitting compositions and devices

    DOE Patents [OSTI]

    Ashley, C.S.; Brinker, C.J.; Reed, S.; Walko, R.J.

    1992-08-11

    The invention relates to a composition for the volumetric generation of radiation, wherein a first substance functions as a source of exciting radiation, and a second substance interacts with the exciting radiation to provide a second radiation. The compositions comprise a porous substrate which is loaded with: a source of exciting radiation, a component capable of emitting radiation upon interaction with the exciting radiation, or both. Preferably, the composition is an aerogel substrate loaded with both a source of exciting radiation, such as tritium, and a component capable of interacting with the exciting radiation, e.g., a phosphor, to produce radiation of a second energy. 4 figs.

  3. High efficiency III-nitride light-emitting diodes

    DOE Patents [OSTI]

    Crawford, Mary; Koleske, Daniel; Cho, Jaehee; Zhu, Di; Noemaun, Ahmed; Schubert, Martin F; Schubert, E. Fred

    2013-05-28

    Tailored doping of barrier layers enables balancing of the radiative recombination among the multiple-quantum-wells in III-Nitride light-emitting diodes. This tailored doping enables more symmetric carrier transport and uniform carrier distribution which help to reduce electron leakage and thus reduce the efficiency droop in high-power III-Nitride LEDs. Mitigation of the efficiency droop in III-Nitride LEDs may enable the pervasive market penetration of solid-state-lighting technologies in high-power lighting and illumination.

  4. Poly (p-phenyleneneacetylene) light-emitting diodes

    DOE Patents [OSTI]

    Shinar, Joseph; Swanson, Leland S.; Lu, Feng; Ding, Yiwei; Barton, Thomas J.; Vardeny, Zeev V.

    1994-10-04

    Acetylene containing poly(p-phenyleneacetylene) (PPA) - based light-emitting diodes (LEDs) are provided. The LEDs are fabricated by coating a hole-injecting electrode, preferably an indium tin oxide (ITO) coated glass substrate, with a PPA polymer, such as a 2,5-dibutoxy or a 2,5-dihexoxy derivative of PPA, dissolved in an organic solvent. This is then followed by evaporating a layer of material capable of injecting electrons, such as Al or Al/Ca, onto the polymer to form a base electrode. This composition is then annealed to form efficient EL diodes.

  5. Poly (p-phenyleneacetylene) light-emitting diodes

    DOE Patents [OSTI]

    Shinar, J.; Swanson, L.S.; Lu, F.; Ding, Y.; Barton, T.J.; Vardeny, Z.V.

    1994-10-04

    Acetylene containing poly(p-phenyleneacetylene) (PPA) - based light-emitting diodes (LEDs) are provided. The LEDs are fabricated by coating a hole-injecting electrode, preferably an indium tin oxide (ITO) coated glass substrate, with a PPA polymer, such as a 2,5-dibutoxy or a 2,5-dihexoxy derivative of PPA, dissolved in an organic solvent. This is then followed by evaporating a layer of material capable of injecting electrons, such as Al or Al/Ca, onto the polymer to form a base electrode. This composition is then annealed to form efficient EL diodes. 8 figs.

  6. Fabrication of poly(p-phenyleneacetylene) light-emitting diodes

    DOE Patents [OSTI]

    Shinar, Joseph; Swanson, Leland S.; Lu, Feng; Ding, Yiwei

    1994-08-02

    Acetylene containing poly(p-phenyleneacetylene) (PPA) - based light-emitting diodes (LEDs) are provided. The LEDs are fabricated by coating a hole-injecting electrode, preferably an indium tin oxide (ITO) coated glass substrate, with a PPA polymer, such as a 2,5-dibutoxy or a 2,5-dihexoxy derivative of PPA, dissolved in an organic solvent. This is then followed by evaporating a layer of material capable of injecting electrons, such as A1 or A1/Ca, onto the polymer to form a base electrode. This composition is then annealed to form efficient EL diodes.

  7. Fabrication of poly(p-phenyleneacetylene) light-emitting diodes

    DOE Patents [OSTI]

    Shinar, J.; Swanson, L.S.; Lu, F.; Ding, Y.

    1994-08-02

    Acetylene-containing poly(p-phenyleneacetylene) (PPA)-based light-emitting diodes (LEDs) are provided. The LEDs are fabricated by coating a hole-injecting electrode, preferably an indium tin oxide (ITO) coated glass substrate, with a PPA polymer, such as a 2,5-dibutoxy or a 2,5-dihexoxy derivative of PPA, dissolved in an organic solvent. This is then followed by evaporating a layer of material capable of injecting electrons, such as Al or Al/Ca, onto the polymer to form a base electrode. This composition is then annealed to form efficient EL diodes. 8 figs.

  8. Organimetallic Fluorescent Complex Polymers For Light Emitting Applications

    DOE Patents [OSTI]

    Shi, Song Q.; So, Franky

    1997-10-28

    A fluorescent complex polymer with fluorescent organometallic complexes connected by organic chain spacers is utilized in the fabrication of light emitting devices on a substantially transparent planar substrate by depositing a first conductive layer having p-type conductivity on the planar surface of the substrate, depositing a layer of a hole transporting and electron blocking material on the first conductive layer, depositing a layer of the fluorescent complex polymer on the layer of hole transporting and electron blocking material as an electron transporting emissive layer and depositing a second conductive layer having n-type conductivity on the layer of fluorescent complex polymer.

  9. Analysis of hydrogen isotope mixtures

    DOE Patents [OSTI]

    Villa-Aleman, Eliel

    1994-01-01

    An apparatus and method for determining the concentrations of hydrogen isotopes in a sample. Hydrogen in the sample is separated from other elements using a filter selectively permeable to hydrogen. Then the hydrogen is condensed onto a cold finger or cryopump. The cold finger is rotated as pulsed laser energy vaporizes a portion of the condensed hydrogen, forming a packet of molecular hydrogen. The desorbed hydrogen is ionized and admitted into a mass spectrometer for analysis.

  10. Alpha particles diffusion due to charge changes

    SciTech Connect (OSTI)

    Clauser, C. F. Farengo, R.

    2015-12-15

    Alpha particles diffusion due to charge changes in a magnetized plasma is studied. Analytical calculations and numerical simulations are employed to show that this process can be very important in the pedestal-edge-SOL regions. This is the first study that presents clear evidence of the importance of atomic processes on the diffusion of alpha particles. A simple 1D model that includes inelastic collisions with plasma species, “cold” neutrals, and partially ionized species was employed. The code, which follows the exact particle orbits and includes the effect of inelastic collisions via a Monte Carlo type random process, runs on a graphic processor unit (GPU). The analytical and numerical results show excellent agreement when a uniform background (plasma and cold species) is assumed. The simulations also show that the gradients in the density of the plasma and cold species, which are large and opposite in the edge region, produce an inward flux of alpha particles. Calculations of the alpha particles flux reaching the walls or divertor plates should include these processes.

  11. Transformer Recharging with Alpha Channeling in Tokamaks

    SciTech Connect (OSTI)

    N.J. Fisch

    2009-12-21

    Transformer recharging with lower hybrid waves in tokamaks can give low average auxiliary power if the resistivity is kept high enough during the radio frequency (rf) recharging stage. At the same time, operation in the hot ion mode via alpha channeling increases the effective fusion reactivity. This paper will address the extent to which these two large cost saving steps are compatible. __________________________________________________

  12. Method of making nanocrystalline alpha alumina

    DOE Patents [OSTI]

    Siegel, Richard W.; Hahn, Horst; Eastman, Jeffrey A.

    1992-01-01

    Method of making selected phases of nanocrystalline ceramic materials. Various methods of controlling the production of nanocrystalline alpha alumina and titanium oxygen phases are described. Control of the gas atmosphere and use of particular oxidation treatments give rise to the ability to control the particular phases provided in the aluminum/oxygen and titanium/oxygen system.

  13. Rossi alpha Measurements and Calculations for HEU/Pb Core (Technical...

    Office of Scientific and Technical Information (OSTI)

    Rossi alpha Measurements and Calculations for HEUPb Core Citation Details In-Document Search Title: Rossi alpha Measurements and Calculations for HEUPb Core Rossi alpha ...

  14. Suppressing spectral diffusion of emitted photons with optical pulses

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Fotso, H. F.; Feiguin, A. E.; Awschalom, D. D.; Dobrovitski, V. V.

    2016-01-22

    In many quantum architectures the solid-state qubits, such as quantum dots or color centers, are interfaced via emitted photons. However, the frequency of photons emitted by solid-state systems exhibits slow uncontrollable fluctuations over time (spectral diffusion), creating a serious problem for implementation of the photon-mediated protocols. Here we show that a sequence of optical pulses applied to the solid-state emitter can stabilize the emission line at the desired frequency. We demonstrate efficiency, robustness, and feasibility of the method analytically and numerically. Taking nitrogen-vacancy center in diamond as an example, we show that only several pulses, with the width of 1more » ns, separated by few ns (which is not difficult to achieve) can suppress spectral diffusion. As a result, our method provides a simple and robust way to greatly improve the efficiency of photon-mediated entanglement and/or coupling to photonic cavities for solid-state qubits.« less

  15. Organic light-emitting devices using spin-dependent processes

    DOE Patents [OSTI]

    Vardeny, Z. Valy; Wohlgenannt, Markus

    2010-03-23

    The maximum luminous efficiency of organic light-emitting materials is increased through spin-dependent processing. The technique is applicable to all electro-luminescent processes in which light is produced by singlet exciton decay, and all devices which use such effects, including LEDs, super-radiant devices, amplified stimulated emission devices, lasers, other optical microcavity devices, electrically pumped optical amplifiers, and phosphorescence (Ph) based light emitting devices. In preferred embodiments, the emissive material is doped with an impurity, or otherwise modified, to increase the spin-lattice relaxation rate (i.e., decrease the spin-lattice time), and hence raise the efficiency of the device. The material may be a polymer, oligomer, small molecule, single crystal, molecular crystal, or fullerene. The impurity is preferably a magnetic or paramagnetic substance. The invention is applicable to IR, UV, and other electromagnetic radiation generation and is thus not limited to the visible region of the spectrum. The methods of the invention may also be combined with other techniques used to improve device performance.

  16. CX-000882: Categorical Exclusion Determination

    Office of Energy Efficiency and Renewable Energy (EERE)

    Separation of Alpha Emitting IsotopesCX(s) Applied: B3.6Date: 02/23/2010Location(s): Aiken, South CarolinaOffice(s): Environmental Management, Savannah River Operations Office

  17. Antibody-mediated reduction of .alpha.-ketoamides

    DOE Patents [OSTI]

    Schultz, Peter G.; Gallop, Mark A.

    1998-01-01

    Monoclonal antibodies raised against a 4-nitrophenyl phosphonate hapten catalyze the stereospecific reduction of an .alpha.-ketoamide to the corresponding .alpha.-hydroxyamide in the presence of an appropriate reducing agent.

  18. Antibody-mediated reduction of {alpha}-ketoamides

    DOE Patents [OSTI]

    Schultz, P.G.; Gallop, M.A.

    1998-06-09

    Monoclonal antibodies raised against a 4-nitrophenyl phosphonate hapten catalyze the stereospecific reduction of an {alpha}-ketoamide to the corresponding {alpha}-hydroxyamide in the presence of an appropriate reducing agent.

  19. Alpha Calutron tank | Y-12 National Security Complex

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Calutron tank Alpha Calutron tank The C-shaped alpha calutron tank, together with its emitters and collectors on the lower-edge door, was removed in a special drydock from the magnet for the recovery of uranium-235

  20. RAPID DETERMINATION OF ACTINIDES IN URINE BY INDUCTIVELY-COUPLED PLASMA MASS SPECTROMETRY AND ALPHA SPECTROMETRY: A HYBRID APPROACH

    SciTech Connect (OSTI)

    Maxwell, S.; Jones, V.

    2009-05-27

    A new rapid separation method that allows separation and preconcentration of actinides in urine samples was developed for the measurement of longer lived actinides by inductively coupled plasma mass spectrometry (ICP-MS) and short-lived actinides by alpha spectrometry; a hybrid approach. This method uses stacked extraction chromatography cartridges and vacuum box technology to facilitate rapid separations. Preconcentration, if required, is performed using a streamlined calcium phosphate precipitation. Similar technology has been applied to separate actinides prior to measurement by alpha spectrometry, but this new method has been developed with elution reagents now compatible with ICP-MS as well. Purified solutions are split between ICP-MS and alpha spectrometry so that long- and short-lived actinide isotopes can be measured successfully. The method allows for simultaneous extraction of 24 samples (including QC samples) in less than 3 h. Simultaneous sample preparation can offer significant time savings over sequential sample preparation. For example, sequential sample preparation of 24 samples taking just 15 min each requires 6 h to complete. The simplicity and speed of this new method makes it attractive for radiological emergency response. If preconcentration is applied, the method is applicable to larger sample aliquots for occupational exposures as well. The chemical recoveries are typically greater than 90%, in contrast to other reported methods using flow injection separation techniques for urine samples where plutonium yields were 70-80%. This method allows measurement of both long-lived and short-lived actinide isotopes. 239Pu, 242Pu, 237Np, 243Am, 234U, 235U and 238U were measured by ICP-MS, while 236Pu, 238Pu, 239Pu, 241Am, 243Am and 244Cm were measured by alpha spectrometry. The method can also be adapted so that the separation of uranium isotopes for assay is not required, if uranium assay by direct dilution of the urine sample is preferred instead

  1. Stable Isotope Enrichment Capabilities at ORNL

    SciTech Connect (OSTI)

    Egle, Brian; Aaron, W Scott; Hart, Kevin J

    2013-01-01

    The Oak Ridge National Laboratory (ORNL) and the US Department of Energy Nuclear Physics Program have built a high-resolution Electromagnetic Isotope Separator (EMIS) as a prototype for reestablishing a US based enrichment capability for stable isotopes. ORNL has over 60 years of experience providing enriched stable isotopes and related technical services to the international accelerator target community, as well as medical, research, industrial, national security, and other communities. ORNL is investigating the combined use of electromagnetic and gas centrifuge isotope separation technologies to provide research quantities (milligram to several kilograms) of enriched stable isotopes. In preparation for implementing a larger scale production facility, a 10 mA high-resolution EMIS prototype has been built and tested. Initial testing of the device has simultaneously collected greater than 98% enriched samples of all the molybdenum isotopes from natural abundance feedstock.

  2. METHOD AND APPARATUS FOR COLLECTING ISOTOPES

    DOE Patents [OSTI]

    Leyshon, W.E.

    1957-08-01

    A method and apparatus for collecting isotopes having a high vapor pressure, such as isotopes of mercury, in a calutron are described. Heretofore, the collected material would vaporize and escape from the ion receiver as fast as it was received. By making the receiver of pure silver, the mercury isotopes form a nonvolatile amalgam with the silver at the water cooled temperature of the receiver, and the mercury is thus retained.

  3. White top-emitting organic light-emitting diodes with solution-processed nano-particle scattering layers

    SciTech Connect (OSTI)

    Schaefer, Tim; Schwab, Tobias; Lenk, Simone; Gather, Malte C.

    2015-12-07

    A random scattering approach to enhance light extraction in white top-emitting organic light-emitting diodes (OLEDs) is reported. Through solution processing from fluorinated solvents, a nano-particle scattering layer (NPSL) can be deposited directly on top of small molecule OLEDs without affecting their electrical performance. The scattering length for light inside the NPSL is determined from transmission measurements and found to be in agreement with Mie scattering theory. Furthermore, the dependence of the light outcoupling enhancement on electron transport layer thickness is studied. Depending on the electron transport layer thickness, the NPSL enhances the external quantum efficiency of the investigated white OLEDs by between 1.5 and 2.3-fold. For a device structure that has been optimized prior to application of the NPSL, the maximum external quantum efficiency is improved from 4.7% to 7.4% (1.6-fold improvement). In addition, the scattering layer strongly reduces the undesired shift in emission color with viewing angle.

  4. Categorical Exclusion 4577: Lithium Isotope Separation & Enrichment...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lithium Isotope Separation & Enrichment Technologies (4577) Program or Field Office: Y-12 Site Office Location(s) (CityCountyState): Oak Ridge, Anderson County, Tennessee...

  5. Atomic vapor laser isotope separation process

    DOE Patents [OSTI]

    Wyeth, Richard W.; Paisner, Jeffrey A.; Story, Thomas

    1990-01-01

    A laser spectroscopy system is utilized in an atomic vapor laser isotope separation process. The system determines spectral components of an atomic vapor utilizing a laser heterodyne technique.

  6. Isotope production agreement benefits medical patients | National...

    National Nuclear Security Administration (NNSA)

    LLC (NSTec), and Henderson, Nevada-based Global Medical Isotope Systems, LLC (GMIS). ... Known primarily as the management and operations contractor for the Nevada National ...

  7. Method for isotope enrichment by photoinduced chemiionization

    DOE Patents [OSTI]

    Dubrin, James W.

    1985-01-01

    Isotope enrichment, particularly .sup.235 U enrichment, is achieved by irradiating an isotopically mixed vapor feed with radiant energy at a wavelength or wavelengths chosen to selectively excite the species containing a desired isotope to a predetermined energy level. The vapor feed if simultaneously reacted with an atomic or molecular reactant species capable of preferentially transforming the excited species into an ionic product by a chemiionization reaction. The ionic product, enriched in the desired isotope, is electrostatically or electromagnetically extracted from the reaction system.

  8. EIS-0249: Medical Isotopes Production Project

    Broader source: Energy.gov [DOE]

    This EIS evaluates the potential environmental impacts of a proposal to establish a production capability for molybdenum-99 (Mo-99) and related medical isotopes.

  9. Influences of wide-angle and multi-beam interference on the chromaticity and efficiency of top-emitting white organic light-emitting diodes

    SciTech Connect (OSTI)

    Deng, Lingling; Zhou, Hongwei; Chen, Shufen Liu, Bin; Wang, Lianhui; Shi, Hongying

    2015-02-28

    Wide-angle interference (WI) and multi-beam interference (MI) in microcavity are analyzed separately to improve chromaticity and efficiency of the top-emitting white organic light-emitting diodes (TWOLEDs). A classic electromagnetic theory is used to calculate the resonance intensities of WI and MI in top-emitting organic light-emitting diodes (TOLEDs) with influence factors (e.g., electrodes and exciton locations) being considered. The role of WI on the performances of TOLEDs is revealed through using ?-doping technology and comparing blue and red EML positions in top-emitting and bottom-emitting devices. The blue light intensity significantly increases and the chromaticity of TWOLEDs is further improved with the use of enhanced WI (the blue emitting layer moving towards the reflective electrode) in the case of a weak MI. In addition, the effect of the thicknesses of light output layer and carrier transport layers on WI and MI are also investigated. Apart from the microcavity effect, other factors, e.g., carrier balance and carrier recombination regions are considered to obtain TWOLEDs with high efficiency and improved chromaticity near white light equal-energy point.

  10. Uranium isotopes fingerprint biotic reduction

    SciTech Connect (OSTI)

    Stylo, Malgorzata; Neubert, Nadja; Wang, Yuheng; Monga, Nikhil; Romaniello, Stephen J.; Weyer, Stefan; Bernier-Latmani, Rizlan

    2015-04-20

    Knowledge of paleo-redox conditions in the Earth’s history provides a window into events that shaped the evolution of life on our planet. The role of microbial activity in paleo-redox processes remains unexplored due to the inability to discriminate biotic from abiotic redox transformations in the rock record. The ability to deconvolute these two processes would provide a means to identify environmental niches in which microbial activity was prevalent at a specific time in paleo-history and to correlate specific biogeochemical events with the corresponding microbial metabolism. Here, we demonstrate that the isotopic signature associated with microbial reduction of hexavalent uranium (U), i.e., the accumulation of the heavy isotope in the U(IV) phase, is readily distinguishable from that generated by abiotic uranium reduction in laboratory experiments. Thus, isotope signatures preserved in the geologic record through the reductive precipitation of uranium may provide the sought-after tool to probe for biotic processes. Because uranium is a common element in the Earth’s crust and a wide variety of metabolic groups of microorganisms catalyze the biological reduction of U(VI), this tool is applicable to a multiplicity of geological epochs and terrestrial environments. The findings of this study indicate that biological activity contributed to the formation of many authigenic U deposits, including sandstone U deposits of various ages, as well as modern, Cretaceous, and Archean black shales. In addition, engineered bioremediation activities also exhibit a biotic signature, suggesting that, although multiple pathways may be involved in the reduction, direct enzymatic reduction contributes substantially to the immobilization of uranium.

  11. Uranium isotopes fingerprint biotic reduction

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Stylo, Malgorzata; Neubert, Nadja; Wang, Yuheng; Monga, Nikhil; Romaniello, Stephen J.; Weyer, Stefan; Bernier-Latmani, Rizlan

    2015-04-20

    Knowledge of paleo-redox conditions in the Earth’s history provides a window into events that shaped the evolution of life on our planet. The role of microbial activity in paleo-redox processes remains unexplored due to the inability to discriminate biotic from abiotic redox transformations in the rock record. The ability to deconvolute these two processes would provide a means to identify environmental niches in which microbial activity was prevalent at a specific time in paleo-history and to correlate specific biogeochemical events with the corresponding microbial metabolism. Here, we demonstrate that the isotopic signature associated with microbial reduction of hexavalent uranium (U),more » i.e., the accumulation of the heavy isotope in the U(IV) phase, is readily distinguishable from that generated by abiotic uranium reduction in laboratory experiments. Thus, isotope signatures preserved in the geologic record through the reductive precipitation of uranium may provide the sought-after tool to probe for biotic processes. Because uranium is a common element in the Earth’s crust and a wide variety of metabolic groups of microorganisms catalyze the biological reduction of U(VI), this tool is applicable to a multiplicity of geological epochs and terrestrial environments. The findings of this study indicate that biological activity contributed to the formation of many authigenic U deposits, including sandstone U deposits of various ages, as well as modern, Cretaceous, and Archean black shales. In addition, engineered bioremediation activities also exhibit a biotic signature, suggesting that, although multiple pathways may be involved in the reduction, direct enzymatic reduction contributes substantially to the immobilization of uranium.« less

  12. Automatically processed alpha-track radon monitor

    DOE Patents [OSTI]

    Langner, G.H. Jr.

    1993-01-12

    An automatically processed alpha-track radon monitor is provided which includes a housing having an aperture allowing radon entry, and a filter that excludes the entry of radon daughters into the housing. A flexible track registration material is located within the housing that records alpha-particle emissions from the decay of radon and radon daughters inside the housing. The flexible track registration material is capable of being spliced such that the registration material from a plurality of monitors can be spliced into a single strip to facilitate automatic processing of the registration material from the plurality of monitors. A process for the automatic counting of radon registered by a radon monitor is also provided.

  13. Proceedings, High-Precision $\\alpha_s$ Measurements from LHC to FCC-ee

    SciTech Connect (OSTI)

    d'Enterria, David; Skands, Peter Z.

    2015-01-01

    This document provides a writeup of all contributions to the workshop on "High precision measurements of $\\alpha_s$: From LHC to FCC-ee" held at CERN, Oct. 12--13, 2015. The workshop explored in depth the latest developments on the determination of the QCD coupling $\\alpha_s$ from 15 methods where high precision measurements are (or will be) available. Those include low-energy observables: (i) lattice QCD, (ii) pion decay factor, (iii) quarkonia and (iv) $\\tau$ decays, (v) soft parton-to-hadron fragmentation functions, as well as high-energy observables: (vi) global fits of parton distribution functions, (vii) hard parton-to-hadron fragmentation functions, (viii) jets in $e^\\pm$p DIS and $\\gamma$-p photoproduction, (ix) photon structure function in $\\gamma$-$\\gamma$, (x) event shapes and (xi) jet cross sections in $e^+e^-$ collisions, (xii) W boson and (xiii) Z boson decays, and (xiv) jets and (xv) top-quark cross sections in proton-(anti)proton collisions. The current status of the theoretical and experimental uncertainties associated to each extraction method, the improvements expected from LHC data in the coming years, and future perspectives achievable in $e^+e^-$ collisions at the Future Circular Collider (FCC-ee) with $\\cal{O}$(1--100 ab$^{-1}$) integrated luminosities yielding 10$^{12}$ Z bosons and jets, and 10$^{8}$ W bosons and $\\tau$ leptons, are thoroughly reviewed. The current uncertainty of the (preliminary) 2015 strong coupling world-average value, $\\alpha_s(m_Z)$ = 0.1177 $\\pm$ 0.0013, is about 1\\%. Some participants believed this may be reduced by a factor of three in the near future by including novel high-precision observables, although this opinion was not universally shared. At the FCC-ee facility, a factor of ten reduction in the $\\alpha_s$ uncertainty should be possible, mostly thanks to the huge Z and W data samples available.

  14. Uranium molecular laser isotope separation

    SciTech Connect (OSTI)

    Jensen, R.J.; Sullivan, A.

    1982-01-01

    The Molecular Laser Isotope Separation program is moving into the engineering phase, and it is possible to determine in some detail the plant cost terms involved in the process economics. A brief description of the MLIS process physics is given as a motivation to the engineering and economics discussion. Much of the plant cost arises from lasers and the overall optical system. In the paper, the authors discuss lasers as operating units and systems, along with temporal multiplexing and Raman shifting. Estimates of plant laser costs are given.

  15. Hydrogen-isotope permeation barrier

    DOE Patents [OSTI]

    Maroni, Victor A.; Van Deventer, Erven H.

    1977-01-01

    A composite including a plurality of metal layers has a Cu-Al-Fe bronze layer and at least one outer layer of a heat and corrosion resistant metal alloy. The bronze layer is ordinarily intermediate two outer layers of metal such as austenitic stainless steel, nickel alloys or alloys of the refractory metals. The composite provides a barrier to hydrogen isotopes, particularly tritium that can reduce permeation by at least about 30 fold and possibly more below permeation through equal thicknesses of the outer layer material.

  16. Spatial periphery of lithium isotopes

    SciTech Connect (OSTI)

    Galanina, L. I. Zelenskaja, N. S.

    2013-12-15

    The spatial structure of lithium isotopes is studied with the aid of the charge-exchange and (t, p) reactions on lithium nuclei. It is shown that an excited isobaric-analog state of {sup 6}Li (0{sup +}, 3.56MeV) has a halo structure formed by a proton and a neutron, that, in the {sup 9}Li nucleus, there is virtually no neutron halo, and that {sup 11}Li is a Borromean nucleus formed by a {sup 9}Li core and a two-neutron halo manifesting itself in cigar-like and dineutron configurations.

  17. Solid-state radiation-emitting compositions and devices

    DOE Patents [OSTI]

    Ashley, Carol S.; Brinker, C. Jeffrey; Reed, Scott; Shepodd, Timothy J.; Leonard, Leroy E.; Ellefson, Robert E.; Gill, John T.; Walko, Robert J.; Renschler, Clifford L.

    1992-01-01

    The invention relates to a composition for the volumetric generation of radiation, wherein a first substance functions as a source of exciting radiation, and a second substance interacts with the exciting radiation to provide a second radiation. The compositions comprise a porous substrate which is loaded with: a source of exciting radiation, a component capable of emitting radiation upon interaction with the exciting radiation, or both. In the composition, a composite is formed from a carrier material and at least one of the source of the exciting radiation or the component which is capable of interacting with the exciting radiation. The composite is then employed for loading a porous substrate, preferably an aerogel substrate.

  18. Method of electroplating a conversion electron emitting source on implant

    DOE Patents [OSTI]

    Srivastava, Suresh C.; Gonzales, Gilbert R.; Adzic, Radoslav; Meinken, George E.

    2012-02-14

    Methods for preparing an implant coated with a conversion electron emitting source (CEES) are disclosed. The typical method includes cleaning the surface of the implant; placing the implant in an activating solution comprising hydrochloric acid to activate the surface; reducing the surface by H.sub.2 evolution in H.sub.2SO.sub.4 solution; and placing the implant in an electroplating solution that includes ions of the CEES, HCl, H.sub.2SO.sub.4, and resorcinol, gelatin, or a combination thereof. Alternatively, before tin plating, a seed layer is formed on the surface. The electroplated CEES coating can be further protected and stabilized by annealing in a heated oven, by passivation, or by being covered with a protective film. The invention also relates to a holding device for holding an implant, wherein the device selectively prevents electrodeposition on the portions of the implant contacting the device.

  19. Electrically pumped edge-emitting photonic bandgap semiconductor laser

    DOE Patents [OSTI]

    Lin, Shawn-Yu; Zubrzycki, Walter J.

    2004-01-06

    A highly efficient, electrically pumped edge-emitting semiconductor laser based on a one- or two-dimensional photonic bandgap (PBG) structure is described. The laser optical cavity is formed using a pair of PBG mirrors operating in the photonic band gap regime. Transverse confinement is achieved by surrounding an active semiconductor layer of high refractive index with lower-index cladding layers. The cladding layers can be electrically insulating in the passive PBG mirror and waveguide regions with a small conducting aperture for efficient channeling of the injection pump current into the active region. The active layer can comprise a quantum well structure. The quantum well structure can be relaxed in the passive regions to provide efficient extraction of laser light from the active region.

  20. Electroluminescence property of organic light emitting diode (OLED)

    SciTech Connect (OSTI)

    zdemir, Orhan; Kavak, Pelin; Saatci, A. Evrim; Gkdemir, F. P?nar; Menda, U. Deneb; Can, Nursel; Kutlu, Kubilay; Tekin, Emine; Pravadal?, Selin

    2013-12-16

    Transport properties of electrons and holes were investigated not only in a anthracene-containing poly(p-phenylene-ethynylene)- alt - poly(p-phenylene-vinylene) (PPE-PPV) polymer (AnE-PVstat) light emitting diodes (OLED) but also in an ITO/Ag/polymer/Ag electron and ITO/PEDOT:PSS/polymer/Au hole only devices. Mobility of injected carriers followed the Poole-Frenkel type conduction mechanism and distinguished in the frequency range due to the difference of transit times in admittance measurement. Beginning of light output took place at the turn-on voltage (or flat band voltage), 1.8 V, which was the difference of energy band gap of polymer and two barrier offsets between metals and polymer.

  1. Tunnel junction enhanced nanowire ultraviolet light emitting diodes

    SciTech Connect (OSTI)

    Sarwar, A. T. M. Golam; May, Brelon J.; Deitz, Julia I.; Grassman, Tyler J.; McComb, David W.; Myers, Roberto C.

    2015-09-07

    Polarization engineered interband tunnel junctions (TJs) are integrated in nanowire ultraviolet (UV) light emitting diodes (LEDs). A ∼6 V reduction in turn-on voltage is achieved by the integration of tunnel junction at the base of polarization doped nanowire UV LEDs. Moreover, efficient hole injection into the nanowire LEDs leads to suppressed efficiency droop in TJ integrated nanowire LEDs. The combination of both reduced bias voltage and increased hole injection increases the wall plug efficiency in these devices. More than 100 μW of UV emission at ∼310 nm is measured with external quantum efficiency in the range of 4–6 m%. The realization of tunnel junction within the nanowire LEDs opens a pathway towards the monolithic integration of cascaded multi-junction nanowire LEDs on silicon.

  2. Detection of alpha radiation in a beta radiation field

    DOE Patents [OSTI]

    Mohagheghi, Amir H.; Reese, Robert P.

    2001-01-01

    An apparatus and method for detecting alpha particles in the presence of high activities of beta particles utilizing an alpha spectrometer. The apparatus of the present invention utilizes a magnetic field applied around the sample in an alpha spectrometer to deflect the beta particles from the sample prior to reaching the detector, thus permitting detection of low concentrations of alpha particles. In the method of the invention, the strength of magnetic field required to adequately deflect the beta particles and permit alpha particle detection is given by an algorithm that controls the field strength as a function of sample beta energy and the distance of the sample to the detector.

  3. Alpha Particle Physics Experiments in the Tokamak Fusion Test Reactor

    SciTech Connect (OSTI)

    Budny, R.V.; Darrow, D.S.; Medley, S.S.; Nazikian, R.; Zweben, S.J.; et al.

    1998-12-14

    Alpha particle physics experiments were done on the Tokamak Fusion Test Reactor (TFTR) during its deuterium-tritium (DT) run from 1993-1997. These experiments utilized several new alpha particle diagnostics and hundreds of DT discharges to characterize the alpha particle confinement and wave-particle interactions. In general, the results from the alpha particle diagnostics agreed with the classical single-particle confinement model in magnetohydrodynamic (MHD) quiescent discharges. Also, the observed alpha particle interactions with sawteeth, toroidal Alfvn eigenmodes (TAE), and ion cyclotron resonant frequency (ICRF) waves were roughly consistent with theoretical modeling. This paper reviews what was learned and identifies what remains to be understood.

  4. Low Voltage, Low Power Organic Light Emitting Transistors for AMOLED Displays

    SciTech Connect (OSTI)

    McCarthy, M. A. [University of Florida, Gainesville; Liu, B. [University of Florida, Gainesville; Donoghue, E. P. [University of Florida, Gainesville; Kravchenko, Ivan I [ORNL; Kim, D. Y. [University of Florida, Gainesville; Reynolds, J. R. [University of Florida, Gainesville; So, Franky [University of Florida, Gainesville; Rinzler, A. G. [University of Florida, Gainesville

    2011-01-01

    Low voltage, low power dissipation, high aperture ratio organic light emitting transistors are demonstrated. The high level of performance is enabled by a carbon nanotube source electrode that permits integration of the drive transistor and the organic light emitting diode into an efficient single stacked device. Given the demonstrated performance, this technology could break the technical logjam holding back widespread deployment of active matrix organic light emitting displays at flat panel screen sizes.

  5. 2014-05-16 Issuance: Test Procedures for Integrated Light-Emitting Diode

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Lamps; Supplemental Notice of Proposed Rulemaking | Department of Energy 16 Issuance: Test Procedures for Integrated Light-Emitting Diode Lamps; Supplemental Notice of Proposed Rulemaking 2014-05-16 Issuance: Test Procedures for Integrated Light-Emitting Diode Lamps; Supplemental Notice of Proposed Rulemaking This document is a pre-publication Federal Register supplemental notice of proposed rulemaking regarding test procedures for integrated light-emitting diode lamps, as issued by the

  6. Red-Emitting Phosphors for Solid-State Lighting - Energy Innovation Portal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Industrial Technologies Industrial Technologies Electricity Transmission Electricity Transmission Advanced Materials Advanced Materials Find More Like This Return to Search Red-Emitting Phosphors for Solid-State Lighting Sandia National Laboratories Contact SNL About This Technology Publications: PDF Document Publication Market Sheet (851 KB) Technology Marketing SummarySandia has developed red-emitting phosphors that will help to transform the cold blue of many current light-emitting diodes

  7. Organic light-emitting device with a phosphor-sensitized fluorescent emission layer

    DOE Patents [OSTI]

    Forrest, Stephen; Kanno, Hiroshi

    2009-08-25

    The present invention relates to organic light emitting devices (OLEDs), and more specifically to OLEDS that emit light using a combination of fluorescent emitters and phosphorescent emitters. The emissive region of the devices of the present invention comprise at least one phosphor-sensitized layer which has a combined emission from a phosphorescent emitter and a fluorescent emitter. In preferred embodiments, the invention relates to white-emitting OLEDS (WOLEDs).

  8. Climate Change Update: Baseload Geothermal is One of the Lowest Emitting

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Technologies | Department of Energy Climate Change Update: Baseload Geothermal is One of the Lowest Emitting Energy Technologies Climate Change Update: Baseload Geothermal is One of the Lowest Emitting Energy Technologies June 26, 2013 - 11:53am Addthis Geothermal energy - energy derived from the heat of the earth - has the ability to produce electricity consistently around the clock, draws a small environmental footprint, and emits little or no greenhouse gases (GHG). Estimates of

  9. Complex-Energy Shell-Model Description of Alpha Decay

    SciTech Connect (OSTI)

    Id Betan, R.; Nazarewicz, Witold

    2011-01-01

    In his pioneering work of alpha decay, Gamow assumed that the alpha particle formed inside the nucleus tunnels through the barrier of the alpha-daughter potential. The corresponding metastable state can be viewed as a complex-energy solution of the time-independent Schroedinger equation with the outgoing boundary condition. The formation of the alpha cluster, missing in the original Gamow formulation, can be described within the R-matrix theory in terms of the formation amplitude. In this work, the alpha decay process is described by computing the formation amplitude and barrier penetrability in a large complex-energy configuration space spanned by the complex-energy eigenstates of the finite Woods-Saxon (WS) potential. The proper normalization of the decay channel is essential as it strongly modifies the alpha-decay spectroscopic factor. The test calculations are carried out for the ^{212}Po alpha decay.

  10. Environmental barrier material for organic light emitting device and method of making

    DOE Patents [OSTI]

    Graff, Gordon L [West Richland, WA; Gross, Mark E [Pasco, WA; Affinito, John D [Kennewick, WA; Shi, Ming-Kun [Richland, WA; Hall, Michael [West Richland, WA; Mast, Eric [Richland, WA

    2003-02-18

    An encapsulated organic light emitting device. The device includes a first barrier stack comprising at least one first barrier layer and at least one first polymer layer. There is an organic light emitting layer stack adjacent to the first barrier stack. A second barrier stack is adjacent to the organic light emitting layer stack. The second barrier stack has at least one second barrier layer and at least one second polymer layer. A method of making the encapsulated organic light emitting device is also provided.

  11. Energy Savings Estimates of Light Emitting Diodes in Niche Lighting Applications

    SciTech Connect (OSTI)

    none,

    2011-01-01

    This report is an analysis of niche markets and applications for light-emitting diodes (LEDs), undertaken on behalf of the U.S. Department of Energy.

  12. Energy Savings Estimates of Light Emitting Diodes in Niche Lighting Applications

    SciTech Connect (OSTI)

    None, None

    2008-09-01

    This report is an analysis of niche markets and applications for light-emitting diodes (LEDs), undertaken on behalf of the U.S. Department of Energy.

  13. High performance flexible top-emitting warm-white organic light...

    Office of Scientific and Technical Information (OSTI)

    TCTA. By adjusting the relative position of the orange-red EML sandwiched between the blue emitting layers, the optimized device exhibits the highest powercurrent efficiency of...

  14. Low-Cost Light-Emitting Diode Luminaire for General Illumination

    Broader source: Energy.gov [DOE]

    This project is demonstrating an efficient and stable white organic light-emitting diode (WOLED) using a single emitter on a planar glass substrate.

  15. Demonstration Assessment of Light-Emitting Diode (LED) Area Lights for a Commercial Garage

    SciTech Connect (OSTI)

    2008-11-01

    This U.S. Department of Energy GATEWAY Demonstration project studied the applicability of light-emitting diode (LED) luminaires for commercial parking garage applications.

  16. Utilizing Isotopic Uranium Ratios in Groundwater Evaluations at NFSS

    SciTech Connect (OSTI)

    Rhodes, M.C.; Keil, K.G.; Frederick, W.T.; Papura, T.R.; Leithner, J.S.; Peterson, J.M.; MacDonell, M.M.

    2006-07-01

    The U.S. Army Corps of Engineers (USACE) Buffalo District is currently evaluating environmental contamination at the Niagara Falls Storage Site (NFSS) under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) as part of its Formerly Utilized Sites Remedial Action Program (FUSRAP). The NFSS is located in the Town of Lewiston in western New York and has been used to store uranium-contaminated materials since 1944. Most of the radioactive materials are currently contained in an on-site structure, but past contamination remains in soil and groundwater. As a naturally occurring radionuclide, uranium is present in all groundwater. Because contamination levels at the site are quite low, it can be difficult to distinguish zones that have been impacted by the past releases from those at the high end of the natural background range. The differences in the isotopic ratio of uranium-234 (U-234) to uranium-238 (U-238) between natural groundwater systems and affected areas are being used in an innovative way to better define the nature and extent of groundwater contamination at NFSS. In natural groundwater, the ratio of U-234 to U-238 exceeds 1 due to the alpha particle recoil effect, in which U-234 is preferentially mobilized to groundwater from adjacent rock or soil. This process is very slow, and it can be hundreds to thousands of years before a measurable impact is seen in the isotopic ratio. Thus, as a result of the recoil effect, the ratio of U-234 to U-238 will be higher in natural groundwater than in contaminated groundwater. This means that if site releases were the source of the uranium being measured in groundwater at NFSS, the ratio of U-234 to U-238 would be expected to be very close to 1 (the same ratio that exists in wastes and soil at the site), because not enough time has elapsed for the alpha particle recoil effect to have significantly altered that ratio. From an evaluation of site and regional groundwater data, an isotopic ratio

  17. Efficient palladium isotope chromatograph for hydrogen (EPIC)

    SciTech Connect (OSTI)

    Embury, M.C.; Ellefson, R.E.; Melke, H.B. )

    1992-03-01

    The Efficient Palladium Isotope Chromatograph (EPIC) is a rapid cycling, computer-operated displacement chromatograph for the separation of hydrogen isotopes. EPIC incorporates several features that optimize product throughput and purity. This paper describes this palladium displacement chromatograph, the operations with protium and deuterium, and the design modifications for operation with tritium.

  18. Isotope separation by selective photodissociation of glyoxal

    DOE Patents [OSTI]

    Marling, John B.

    1976-01-01

    Dissociation products, mainly formaldehyde and carbon monoxide, enriched in a desired isotope of carbon, oxygen, or hydrogen are obtained by the selective photodissociation of glyoxal wherein glyoxal is subjected to electromagnetic radiation of a predetermined wavelength such that photon absorption excites and induces dissociation of only those molecules of glyoxal containing the desired isotope.

  19. Isotope mass spectrometry from 1968 to 1989

    SciTech Connect (OSTI)

    DeBievre, P. )

    1989-11-01

    The principal developments in isotope mass spectrometry are described with respect to instrument construction, detector technology, measurement precision, measurement accuracy, and reference materials. The increase in the application of isotope mass spectrometry is summarized, with special emphasis on its use in safeguards of nuclear materials. The future potential versus the present achievements of the field are discussed.

  20. Advanced Mass Spectrometers for Hydrogen Isotope Analyses

    SciTech Connect (OSTI)

    Chastagner, P.

    2001-08-01

    This report is a summary of the results of a joint Savannah River Laboratory (SRL) - Savannah River Plant (SRP) ''Hydrogen Isotope Mass Spectrometer Evaluation Program''. The program was undertaken to evaluate two prototype hydrogen isotope mass spectrometers and obtain sufficient data to permit SRP personnel to specify the mass spectrometers to replace obsolete instruments.

  1. iso-brochure-6-29-outside

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Our Capabilities Isotopes for Nuclear Medicine Isotopes for Fundamental Science We save lives * LANL is a major domestic supplier of the important diagnostic isotopes Sr-82 and Ge-68 and is researching methods to increase supply to meet the needs of the medical community. * The Isotope Program is actively researching the production of isotopes for therapeutic applications, including promising alpha-emitting radionuclides for targeted radiotherapy such as Ac-225. IPF integrates with researchers

  2. Plutonium Isotopes in the Terrestrial Environment at the Savannah...

    Office of Scientific and Technical Information (OSTI)

    Plutonium Isotopes in the Terrestrial Environment at the Savannah River Site, USA. A Long-Term Study Citation Details In-Document Search Title: Plutonium Isotopes in the ...

  3. Advances in Hydrogen Isotope Separation Using Thermal Cycling...

    Office of Environmental Management (EM)

    Hydrogen Isotope Separation Using Thermal Cycling Absorption Process (TCAP) Advances in Hydrogen Isotope Separation Using Thermal Cycling Absorption Process (TCAP) Presentation ...

  4. Manus Water Isotope Investigation Field Campaign Report (Program...

    Office of Scientific and Technical Information (OSTI)

    SciTech Connect Search Results Program Document: Manus Water Isotope Investigation Field Campaign Report Citation Details In-Document Search Title: Manus Water Isotope ...

  5. Review of hydrogen isotope permeability through materials (Technical...

    Office of Scientific and Technical Information (OSTI)

    Review of hydrogen isotope permeability through materials Citation Details In-Document Search Title: Review of hydrogen isotope permeability through materials You are accessing ...

  6. Expert Panel: Forecast Future Demand for Medical Isotopes | Department...

    Office of Environmental Management (EM)

    Though the cost of providing a reliable and diverse supply of isotopes for medical use may ... More Documents & Publications Final Report, NEAC Subcommittee for Isotope Research & ...

  7. Isotopic Analysis At Fenton Hill Hdr Geothermal Area (Goff, Et...

    Open Energy Info (EERE)

    Isotopic Analysis At Fenton Hill Hdr Geothermal Area (Goff, Et Al., 1981) Redirect page Jump to: navigation, search REDIRECT Isotopic Analysis- Fluid At Fenton Hill Hdr Geothermal...

  8. Device and method for separating oxygen isotopes

    DOE Patents [OSTI]

    Rockwood, Stephen D.; Sander, Robert K.

    1984-01-01

    A device and method for separating oxygen isotopes with an ArF laser which produces coherent radiation at approximately 193 nm. The output of the ArF laser is filtered in natural air and applied to an irradiation cell where it preferentially photodissociates molecules of oxygen gas containing .sup.17 O or .sup.18 O oxygen nuclides. A scavenger such as O.sub.2, CO or ethylene is used to collect the preferentially dissociated oxygen atoms and recycled to produce isotopically enriched molecular oxygen gas. Other embodiments utilize an ArF laser which is narrowly tuned with a prism or diffraction grating to preferentially photodissociate desired isotopes. Similarly, desired mixtures of isotopic gas can be used as a filter to photodissociate enriched preselected isotopes of oxygen.

  9. Selected Isotopes for Optimized Fuel Assembly Tags

    SciTech Connect (OSTI)

    Gerlach, David C.; Mitchell, Mark R.; Reid, Bruce D.; Gesh, Christopher J.; Hurley, David E.

    2008-10-01

    In support of our ongoing signatures project we present information on 3 isotopes selected for possible application in optimized tags that could be applied to fuel assemblies to provide an objective measure of burnup. 1. Important factors for an optimized tag are compatibility with the reactor environment (corrosion resistance), low radioactive activation, at least 2 stable isotopes, moderate neutron absorption cross-section, which gives significant changes in isotope ratios over typical fuel assembly irradiation levels, and ease of measurement in the SIMS machine 2. From the candidate isotopes presented in the 3rd FY 08 Quarterly Report, the most promising appear to be Titanium, Hafnium, and Platinum. The other candidate isotopes (Iron, Tungsten, exhibited inadequate corrosion resistance and/or had neutron capture cross-sections either too high or too low for the burnup range of interest.

  10. {alpha} decay and shape coexistence in the {alpha}-rotor model

    SciTech Connect (OSTI)

    Richards, J.D.; Bingham, C.R.; Nazarewicz, W.; Wauters, J.; Berggren, T.; Berggren, T.; Bingham, C.R.; Nazarewicz, W.; Nazarewicz, W.

    1997-09-01

    The particle-plus-rotor model was employed to study the fine structure seen in the {alpha} decay of even-even neutron-deficient nuclei in the Hg-Po region. The configuration mixing resulting from the shape coexistence between well-deformed prolate bands and spherical (or quasirotational oblate) structures in the daughter nuclei was considered. Experimental {alpha}-decay branching ratios are reproduced within one order of magnitude, except for the case of {sup 180}Hg, where the daughter nucleus {sup 176}Pt is expected to be triaxial in its ground state. The effect of configuration mixing on the relative intensities is discussed in detail, together with the sensitivity of results to the choice of the {alpha}-nucleus optical model parameters. {copyright} {ital 1997} {ital The American Physical Society}

  11. Atomic vapor laser isotope separation of lead-210 isotope

    DOE Patents [OSTI]

    Scheibner, Karl F.; Haynam, Christopher A.; Johnson, Michael A.; Worden, Earl F.

    1999-01-01

    An isotopically selective laser process and apparatus for removal of Pb-210 from natural lead that involves a one-photon near-resonant, two-photon resonant excitation of one or more Rydberg levels, followed by field ionization and then electrostatic extraction. The wavelength to the near-resonant intermediate state is counter propagated with respect to the second wavelength required to populate the final Rydberg state. This scheme takes advantage of the large first excited state cross section, and only modest laser fluences are required. The non-resonant process helps to avoid two problems: first, stimulated Raman Gain due to the nearby F=3/2 hyperfine component of Pb-207 and, second, direct absorption of the first transition process light by Pb-207.

  12. Atomic vapor laser isotope separation of lead-210 isotope

    DOE Patents [OSTI]

    Scheibner, K.F.; Haynam, C.A.; Johnson, M.A.; Worden, E.F.

    1999-08-31

    An isotopically selective laser process and apparatus for removal of Pb-210 from natural lead that involves a one-photon near-resonant, two-photon resonant excitation of one or more Rydberg levels, followed by field ionization and then electrostatic extraction. The wavelength to the near-resonant intermediate state is counter propagated with respect to the second wavelength required to populate the final Rydberg state. This scheme takes advantage of the large first excited state cross section, and only modest laser fluences are required. The non-resonant process helps to avoid two problems: first, stimulated Raman Gain due to the nearby F=3/2 hyperfine component of Pb-207 and, second, direct absorption of the first transition process light by Pb-207. 5 figs.

  13. DETERMINATION OF 237NP AND PU ISOTOPES IN LARGE SOIL SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

    SciTech Connect (OSTI)

    Maxwell, S.

    2010-07-26

    A new method for the determination of {sup 237}Np and Pu isotopes in large soil samples has been developed that provides enhanced uranium removal to facilitate assay by inductively coupled plasma mass spectrometry (ICP-MS). This method allows rapid preconcentration and separation of plutonium and neptunium in large soil samples for the measurement of {sup 237}Np and Pu isotopes by ICP-MS. {sup 238}U can interfere with {sup 239}Pu measurement by ICP-MS as {sup 238}UH{sup +} mass overlap and {sup 237}Np via {sup 238}U peak tailing. The method provides enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then transferring Pu to DGA resin for additional purification. The decontamination factor for removal of uranium from plutonium for this method is greater than 1 x 10{sup 6}. Alpha spectrometry can also be applied so that the shorter-lived {sup 238}Pu isotope can be measured successfully. {sup 239}Pu, {sup 242}Pu and {sup 237}Np were measured by ICP-MS, while {sup 236}Pu and {sup 238}Pu were measured by alpha spectrometry.

  14. Atomic vapor laser isotope separation

    SciTech Connect (OSTI)

    Stern, R.C.; Paisner, J.A.

    1985-11-08

    Atomic vapor laser isotope separation (AVLIS) is a general and powerful technique. A major present application to the enrichment of uranium for light-water power reactor fuel has been under development for over 10 years. In June 1985 the Department of Energy announced the selection of AVLIS as the technology to meet the nation's future need for the internationally competitive production of uranium separative work. The economic basis for this decision is considered, with an indicated of the constraints placed on the process figures of merit and the process laser system. We then trace an atom through a generic AVLIS separator and give examples of the physical steps encountered, the models used to describe the process physics, the fundamental parameters involved, and the role of diagnostic laser measurements.

  15. Apparatus for storing hydrogen isotopes

    DOE Patents [OSTI]

    McMullen, John W.; Wheeler, Michael G.; Cullingford, Hatice S.; Sherman, Robert H.

    1985-01-01

    An improved method and apparatus for storing isotopes of hydrogen (especially tritium) are provided. The hydrogen gas(es) is (are) stored as hydrides of material (for example uranium) within boreholes in a block of copper. The mass of the block is critically important to the operation, as is the selection of copper, because no cooling pipes are used. Because no cooling pipes are used, there can be no failure due to cooling pipes. And because copper is used instead of stainless steel, a significantly higher temperature can be reached before the eutectic formation of uranium with copper occurs, (the eutectic of uranium with the iron in stainless steel forming at a significantly lower temperature).

  16. Synthesis of alpha-amino acids

    DOE Patents [OSTI]

    Davis, Jr., Jefferson W.

    1983-01-01

    A method for synthesizing alpha amino acids proceding through novel intermediates of the formulas: R.sub.1 R.sub.2 C(OSOCl)CN, R.sub.1 R.sub.2 C(Cl)CN and [R.sub.1 R.sub.2 C(CN)O].sub.2 SO wherein R.sub.1 and R.sub.2 are each selected from hydrogen monovalent substituted and unsubstituted hydrocarbon radicals of 1 to 10 carbon atoms. The use of these intermediates allows the synthesis steps to be exothermic and results in an overall synthesis method which is faster than the snythesis methods of the prior art.

  17. Synthesis of alpha-amino acids

    DOE Patents [OSTI]

    Davis, Jr., Jefferson W.

    1983-01-01

    A method for synthesizing alpha amino acids proceeding through novel intermediates of the formulas: R.sub.1 R.sub.2 C(OSOCl)CN, R.sub.1 R.sub.2 C(Cl)CN and [R.sub.1 R.sub.2 C(CN)O].sub.2 SO wherein R.sub.1 and R.sub.2 are each selected from hydrogen monovalent substituted and unsubstituted hydrocarbon radicals of 1 to 12 carbon atoms. The use of these intermediates allows the synthesis steps to be exothermic and results in an overall synthesis method which is faster than the synthesis methods of the prior art.

  18. Synthesis of alpha-amino acids

    DOE Patents [OSTI]

    Davis, Jr., Jefferson W.

    1983-01-01

    A method for synthesizing alpha amino acids proceding through novel intermediates of the formulas: R.sub.1 R.sub.2 C(OSOCl)CN, R.sub.1 R.sub.2 C(Cl)CN and [R.sub.1 R.sub.2 C(CN)O].sub.2 SO wherein R.sub.1 and R.sub.2 are each selected from hydrogen monovalent substituted and unsubstituted hydrocarbon radicals of 1 to 12 carbon atoms. The use of these intermediates allows the synthesis steps to be exothermic and results in an overall synthesis method which is faster than the synthesis methods of the prior art.

  19. Nanocluster-based white-light-emitting material employing surface tuning

    DOE Patents [OSTI]

    Wilcoxon, Jess P.; Abrams, Billie L.; Thoma, Steven G.

    2007-06-26

    A method for making a nanocrystal-based material capable of emitting light over a sufficiently broad spectral range to appear white. Surface-modifying ligands are used to shift and broaden the emission of semiconductor nanocrystals to produce nanoparticle-based materials that emit white light.

  20. Method to generate high efficient devices which emit high quality light for illumination

    DOE Patents [OSTI]

    Krummacher, Benjamin C.; Mathai, Mathew; Choong, Vi-En; Choulis, Stelios A.

    2009-06-30

    An electroluminescent apparatus includes an OLED device emitting light in the blue and green spectrums, and at least one down conversion layer. The down conversion layer absorbs at least part of the green spectrum light and emits light in at least one of the orange spectra and red spectra.

  1. Simulated evolution of fluorophores for light emitting diodes

    SciTech Connect (OSTI)

    Shu, Yinan; Levine, Benjamin G.

    2015-03-14

    Organic light emitting diodes based on fluorophores with a propensity for thermally activated delayed fluorescence (TADF) are able to circumvent limitations imposed on device efficiency by spin statistics. Molecules with a propensity for TADF necessarily have two properties: a small gap between the lowest lying singlet and triplet excited states and a large transition dipole moment for fluorescence. In this work, we demonstrate the use of a genetic algorithm to search a region of chemical space for molecules with these properties. This algorithm is based on a flexible and intuitive representation of the molecule as a tree data structure, in which the nodes correspond to molecular fragments. Our implementation takes advantage of hybrid parallel graphics processing unit accelerated computer clusters to allow efficient sampling while retaining a reasonably accurate description of the electronic structure (in this case, CAM-B3LYP/6-31G{sup ??}). In total, we have identified 3792 promising candidate fluorophores from a chemical space containing 1.26 10{sup 6} molecules. This required performing electronic structure calculations on only 7518 molecules, a small fraction of the full space. Several novel classes of molecules which show promise as fluorophores are presented.

  2. Isotope separation by photoselective dissociative electron capture

    DOE Patents [OSTI]

    Stevens, C.G.

    1978-08-29

    Disclosed is a method of separating isotopes based on photoselective electron capture dissociation of molecules having an electron capture cross section dependence on the vibrational state of the molecule. A molecular isotope source material is irradiated to selectively excite those molecules containing a desired isotope to a predetermined vibrational state having associated therewith an electron capture energy region substantially non-overlapping with the electron capture energy ranges associated with the lowest vibration states of the molecules. The isotope source is also subjected to electrons having an energy corresponding to the non-overlapping electron capture region whereby the selectively excited molecules preferentially capture electrons and dissociate into negative ions and neutrals. The desired isotope may be in the negative ion product or in the neutral product depending upon the mechanism of dissociation of the particular isotope source used. The dissociation product enriched in the desired isotope is then separated from the reaction system by conventional means. Specifically, [sup 235]UF[sub 6] is separated from a UF[sub 6] mixture by selective excitation followed by dissociative electron capture into [sup 235]UF[sub 5]- and F. 2 figs.

  3. Isotope separation by photoselective dissociative electron capture

    DOE Patents [OSTI]

    Stevens, Charles G. [Pleasanton, CA

    1978-08-29

    A method of separating isotopes based on photoselective electron capture dissociation of molecules having an electron capture cross section dependence on the vibrational state of the molecule. A molecular isotope source material is irradiated to selectively excite those molecules containing a desired isotope to a predetermined vibrational state having associated therewith an electron capture energy region substantially non-overlapping with the electron capture energy ranges associated with the lowest vibration states of the molecules. The isotope source is also subjected to electrons having an energy corresponding to the non-overlapping electron capture region whereby the selectively excited molecules preferentially capture electrons and dissociate into negative ions and neutrals. The desired isotope may be in the negative ion product or in the neutral product depending upon the mechanism of dissociation of the particular isotope source used. The dissociation product enriched in the desired isotope is then separated from the reaction system by conventional means. Specifically, .sup.235 UF.sub.6 is separated from a UF.sub.6 mixture by selective excitation followed by dissociative electron capture into .sup.235 UF.sub.5 - and F.

  4. Run Spear Down Low-alpha Shutdown

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Spear Down Low-alpha Shutdown Maintenance / AP University Holidays Sep Oct S 1 Mar Apr May Jun Jul Aug 4/6/2012 SPEAR OPERATING SCHEDULE 2011-2012 2011 2012 Sep Oct Nov Dec Jan Feb 1 2 M 3 1 1 1 S 2 4 1 3 1 AP 2 2 2 W 5 2 4 2 AP AP 3 3 AP 1 3 T 3 5 3 4 1 4 2 4 1 6 4 F 2 7 5 2 1 5 3 1 5 2 T 1 6 4 S 3 8 5 3 7 5 4 1 6 3 2 6 4 2 6 8 5 S 4 9 6 8 6 low 2 7 4 3 7 5 3 7 5 9 MA MA 9 7 M 5 10 3 8 5 4 alpha 8 6 4 T 6 11 8 6 10 8 7 4 9 MA 6 5 9 MA AP 7 13 11 9 W 7 12 9 5 10 AP 7 6 AP 10 8 6 AP 10 AP 7 AP 13

  5. MFTF-. cap alpha. + T progress report

    SciTech Connect (OSTI)

    Nelson, W.D.

    1985-04-01

    Early in FY 1983, several upgrades of the Mirror Fusion Test Facility (MFTF-B) at Lawrence Livermore National Laboratory (LLNL) were proposed to the fusion community. The one most favorably received was designated MFTF-..cap alpha..+T. The engineering design of this device, guided by LLNL, has been a principal activity of the Fusion Engineering Design Center during FY 1983. This interim progress report represents a snapshot of the device design, which was begun in FY 1983 and will continue for several years. The report is organized as a complete design description. Because it is an interim report, some parts are incomplete; they will be supplied as the design study proceeds. As described in this report, MFTF-..cap alpha..+T uses existing facilities, many MFTF-B components, and a number of innovations to improve on the physics parameters of MFTF-B. It burns deuterium-tritium and has a central-cell Q of 2, a wall loading GAMMA/sub n/ of 2 MW/m/sup 2/ (with a central-cell insert module), and an availability of 10%. The machine is fully shielded, allows hands-on maintenance of components outside the vacuum vessel 24 h after shutdown, and has provisions for repair of all operating components.

  6. Performance checks with the Alpha Sentry CAM

    SciTech Connect (OSTI)

    Rodgers, J.C.

    1994-08-01

    Before a CAM is put into service, it must be calibrated. The flow meter and detector must be calibrated with an external flow meter to provide accurate flow data, and the detector must be calibrated to produce accurate DPM data. Both flow and DPM data enter into the calculation of the Derived Air Concentration exposure (DAC-hr) by the CAM software. The focus of this report is on methods for checking that the DAC-hr alarm functionality has been properly calibrated and available in installed CAM instruments. The process begins with detector calibration. In order to calibrate the detector, the Alpha Sentry CAM is placed in an off-line calibration mode and detector efficiency calibration is selected. The user is prompted to enter the calibration source DPM and place the source in the CAM head. Upon latching the filter door with the source in place, a count is automatically initiated and completed. From the count data and the user entered DPM data, an efficiency is determined in the Alpha Sentry Manager (ASM) and stored in non-volatile memory in the CAM head electronics. This source is typically a plated {sup 239}Pu or {sup 241}Am source diffused into a stainless steel planchet.

  7. The Multi-Isotope Process (MIP) Monitor Project: FY12 Progress and Accomplishments

    SciTech Connect (OSTI)

    Coble, Jamie B.; Orton, Christopher R.; Jordan, David V.; Schwantes, Jon M.; Bender, Sarah; Dayman, Kenneth J.; Unlu, Kenan; Landsberger, Sheldon

    2012-09-27

    The Multi-Isotope Process (MIP) Monitor, being developed at Pacific Northwest National Laboratory (PNNL), provides an efficient approach to monitoring the process conditions in reprocessing facilities in support of the goal of "...(minimization of) the risks of nuclear proliferation and terrorism." The MIP Monitor measures distributions of a suite of indicator (radioactive) isotopes present within product and waste streams of a nuclear reprocessing facility. These indicator isotopes are monitored on-line by gamma spectrometry and compared, in near-real-time, to spectral patterns representing "normal" process conditions using multivariate pattern recognition software. The monitor utilizes this multivariate analysis and gamma spectroscopy of reprocessing streams to detect small changes in the gamma spectrum, which may indicate changes in process conditions. Multivariate analysis methods common in chemometrics, such as principal component analysis (PCA) and partial least squares regression (PLS), act as pattern recognition techniques, which can detect small deviations from the expected, nominal condition. By targeting multiple gamma-emitting indicator isotopes, the MIP Monitor approach is compatible with the use of small, portable, relatively high-resolution gamma detectors that may be easily deployed throughout an existing facility. The automated multivariate analysis can provide a level of data obscurity, giving a built-in information barrier to protect sensitive or proprietary operational data. Proof-of-concept simulations and experiments have been performed in previous years to demonstrate the validity of this tool in a laboratory setting. Development of the MIP Monitor approach continues to evaluate the efficacy of the monitor for automated, real-time or near-real-time application. This report details follow-on research and development efforts sponsored by the U.S. Department of Energy Fuel Cycle Research and Development related to the MIP Monitor for fiscal year

  8. Isotope effects on desorption kinetics of hydrogen isotopes implanted into stainless steel by glow discharge

    SciTech Connect (OSTI)

    Matsuyama, M.; Kondo, M.; Noda, N.; Tanaka, M.; Nishimura, K.

    2015-03-15

    In a fusion device the control of fuel particles implies to know the desorption rate of hydrogen isotopes by the plasma-facing materials. In this paper desorption kinetics of hydrogen isotopes implanted into type 316L stainless steel by glow discharge have been studied by experiment and numerical calculation. The temperature of a maximum desorption rate depends on glow discharge time and heating rate. Desorption spectra observed under various experimental conditions have been successfully reproduced by numerical simulations that are based on a diffusion-limited process. It is suggested, therefore, that desorption rate of a hydrogen isotope implanted into the stainless steel is limited by a diffusion process of hydrogen isotope atoms in bulk. Furthermore, small isotope effects were observed for the diffusion process of hydrogen isotope atoms. (authors)

  9. Use of MCNPX for Alpha Spectrometry Simulations of a Continuous...

    Office of Scientific and Technical Information (OSTI)

    spectrum in a Passive Implanted Planar Silicon (PIPS) detector, as modeled by MCNPX 1, ... PROGENY; RADIOISOTOPES; RADON; SILICON Alpha Spectrometry, Continuous Air ...

  10. Probable new type of reaction mechanism: Double. cap alpha. direct...

    Office of Scientific and Technical Information (OSTI)

    Language: English Subject: 73 NUCLEAR PHYSICS AND RADIATION PHYSICS; BERYLLIUM 8; CLUSTER MODEL; BISMUTH 209 TARGET; CARBON 12 REACTIONS; MULTI-NUCLEON TRANSFER REACTIONS; ALPHA ...

  11. Constraining parity and charge-parity violating varying-alpha...

    Office of Scientific and Technical Information (OSTI)

    Constraining parity and charge-parity violating varying-alpha theory through laboratory experiments Citation Details In-Document Search Title: Constraining parity and charge-parity ...

  12. CXD 4605, Disposition Excess Equipment from Alpha 1 (4605)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Disposition Excess Equipment from Alpha 1 (4605) Y-12 Site Office Oak Ridge, Anderson County, Tennessee The proposed action is to characterize and disposition equipment that was...

  13. Carbonitride based phosphors and light emitting devices using the same

    DOE Patents [OSTI]

    Li, Yuanqiang; Tian, Yongchi; Romanelli, Michael Dennis

    2013-08-20

    Disclosed herein is a novel group of carbidonitride phosphors and light emitting devices which utilize these phosphors. In certain embodiments, the present invention is directed to a novel family of carbidonitride-based phosphors expressed as follows: Ca.sub.1-xAl.sub.x-xySi.sub.1-x+xyN.sub.2-x-xyC.sub.xy:A; (1) Ca.sub.1-x-zNa.sub.zM(III).sub.x-xy-zSi.sub.1-x+xy+zN.sub.2-x-xyC.sub.xy:- A; (2) M(II).sub.1-x-zM(I).sub.zM(III).sub.x-xy-zSi.sub.1-x+xy+zN.sub.2-x- -xyC.sub.xy:A; (3) M(II).sub.1-x-zM(I).sub.zM(III).sub.x-xy-zSi.sub.1-x+xy+zN.sub.2-x-xy-2w/- 3C.sub.xyO.sub.w-v/2H.sub.v:A; and (4) M(II).sub.1-x-zM(I).sub.zM(III).sub.x-xy-zSi.sub.1-x+xy+zN.sub.2-x-xy-2w/- 3-v/3C.sub.xyO.sub.wH.sub.v:A, (4a) wherein 0xy+z, and 0

  14. Red-emitting manganese-doped aluminum nitride phosphor

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Cherepy, Nerine J.; Payne, Stephen A.; Harvey, Nicholas M.; Aberg, Daniel; Seeley, Zachary M.; Holliday, Kiel S.; Tran, Ich C.; Zhou, Fei; Martinez, H. Paul; Demeyer, Jessica M.; et al

    2016-02-10

    Here, we report high efficiency luminescence with a manganese-doped aluminum nitride red-emitting phosphor under 254 nm excitation, as well as its excellent lumen maintenance in fluorescent lamp conditions, making it a candidate replacement for the widely deployed europium-doped yttria red phosphor. Solid-state reaction of aluminum nitride powders with manganese metal at 1900 °C, 10 atm N2 in a reducing environment results in nitrogen deficiency, as revealed diffuse reflectance spectra. When these powders are subsequently annealed in flowing nitrogen at 1650 °C, higher nitrogen content is recovered, resulting in white powders. Silicon was added to samples as an oxygen getter tomore » improve emission efficiency. NEXAFS spectra and DFT calculations indicate that the Mn dopant is divalent. From DFT calculations, the UV absorption band is proposed to be due to an aluminum vacancy coupled with oxygen impurity dopants, and Mn2+ is assumed to be closely associated with this site. In contrast with some previous reports, we find that the highest quantum efficiency with 254 nm excitation (Q.E. = 0.86 ± 0.14) is obtained in aluminum nitride with a low manganese doping level of 0.06 mol.%. The principal Mn2+ decay of 1.25 ms is assigned to non-interacting Mn sites, while additional components in the microsecond range appear with higher Mn doping, consistent with Mn clustering and resultant exchange coupling. Slower components are present in samples with low Mn doping, as well as strong afterglow, assigned to trapping on shallow traps followed by detrapping and subsequent trapping on Mn.« less

  15. Y-12 begins to separate lithium isotopes

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    begins to separate lithium isotopes During the years from 1946 through the early 1950s, Y-12 continued to expand as needed to meet the demand for a growing primary mission of...

  16. Atomic vapor laser isotope separation process

    DOE Patents [OSTI]

    Wyeth, R.W.; Paisner, J.A.; Story, T.

    1990-08-21

    A laser spectroscopy system is utilized in an atomic vapor laser isotope separation process. The system determines spectral components of an atomic vapor utilizing a laser heterodyne technique. 23 figs.

  17. AlphaSpectrum ASPECT analysis code for background correction & peak integration

    Energy Science and Technology Software Center (OSTI)

    2005-04-13

    The ASPECT code provides a means for rapid analysis of energy-resolved spectra obtained by multi-channel pulse-height analysis (MCA) during (or after) counting of alpha-emissions from a filter air sample (or other suitably prepared sample) utilizing a solid-state detector, or other detector having sufficient energy resolution indiviual radioisotope peaks indentified in a spectrum are fitted using a peak shape algorithm by non-linear least-square fitting procedures that minimize Chi-square differences between the data and a fitted peakmore » function. The code accomplishes the identification of all significant peaks present in the spectrum with automatic recalibration to the 7.68 Po-214 alpha peak from the Radon-222 decay chain, the subtraction of all radon progeny interference overlaps with lower energy peaks in the energy range of Pu-238, Am-241, Pu-239, and U-234/Th-232, and the integration of the counts in any peak identified for these transuranic radionuclides. The output is therefore in the form of isotope specific net transuranic CPM, DPM or concentration, available in near real-time during air sampling. In this "copyright" version, the assumption is made that the alpha spectra to be analyzed have been stored by unique name in sequential form: "FileName(i)", where "FileName" can be any name and i is the index number of the file saved (e.g., i = 1,2, ..., n). this format is one automatically generated by the alpha Environmental Continuous Air Monitor (ECAM), developed by Los Alamos National Laboratory, and manufactured by Canberra Industries, a Laboratory Industrial Partner for this technology. It is assumed in this version of the code that the alpha spectrum data are stored in a 256 channel spectrum, although a larger num ber of channels could be easily accommodated by small code changes. The ECAM data output format is RADNET compliant (an inidustry standard developed at Los Alamos), and include, in addition to a 256-channel alpha spectrum, data on the

  18. AlphaSpectrum ASPECT analysis code for background correction & peak integration

    Energy Science and Technology Software Center (OSTI)

    2005-04-13

    The ASPECT code provides a means for rapid analysis of energy-resolved spectra obtained by multi-channel pulse-height analysis (MCA) during (or after) counting of alpha-emissions from a filter air sample (or other suitably prepared sample) utilizing a solid-state detector, or other detector having sufficient energy resolution indiviual radioisotope peaks indentified in a spectrum are fitted using a peak shape algorithm by non-linear least-square fitting procedures that minimize Chi-square differences between the data and a fitted peakmorefunction. The code accomplishes the identification of all significant peaks present in the spectrum with automatic recalibration to the 7.68 Po-214 alpha peak from the Radon-222 decay chain, the subtraction of all radon progeny interference overlaps with lower energy peaks in the energy range of Pu-238, Am-241, Pu-239, and U-234/Th-232, and the integration of the counts in any peak identified for these transuranic radionuclides. The output is therefore in the form of isotope specific net transuranic CPM, DPM or concentration, available in near real-time during air sampling. In this "copyright" version, the assumption is made that the alpha spectra to be analyzed have been stored by unique name in sequential form: "FileName(i)", where "FileName" can be any name and i is the index number of the file saved (e.g., i = 1,2, ..., n). this format is one automatically generated by the alpha Environmental Continuous Air Monitor (ECAM), developed by Los Alamos National Laboratory, and manufactured by Canberra Industries, a Laboratory Industrial Partner for this technology. It is assumed in this version of the code that the alpha spectrum data are stored in a 256 channel spectrum, although a larger num ber of channels could be easily accommodated by small code changes. The ECAM data output format is RADNET compliant (an inidustry standard developed at Los Alamos), and include, in addition to a 256-channel alpha spectrum, data on the count

  19. Organic light emitting device architecture for reducing the number of organic materials

    DOE Patents [OSTI]

    D'Andrade, Brian; Esler, James

    2011-10-18

    An organic light emitting device is provided. The device includes an anode and a cathode. A first emissive layer is disposed between the anode and the cathode. The first emissive layer includes a first non-emitting organic material, which is an organometallic material present in the first emissive layer in a concentration of at least 50 wt %. The first emissive layer also includes a first emitting organic material. A second emissive layer is disposed between the first emissive layer and the cathode, preferably, in direct contact with the first emissive layer. The second emissive material includes a second non-emitting organic material and a second emitting organic material. The first and second non-emitting materials, and the first and second emitting materials, are all different materials. A first non-emissive layer is disposed between the first emissive layer and the anode, and in direct contact with the first emissive layer. The first non- emissive layer comprises the first non-emissive organic material.

  20. Environmental assessment: special isotope separation process selection

    SciTech Connect (OSTI)

    Not Available

    1986-04-01

    This Environmental Assessment (EA) evaluates the differences in potential environmental impacts between two plutonium Special Isotope Separation (SIS) technologies: Atomic Vapor Laser Isotope Separation (AVLIS) and Molecular Laser Isotope Separation (MLIS). Both SIS technologies use PuO/sub 2/ as feed; AVLIS converts feed to plutonium metal and MLIS converts feed to PuF/sub 6/. The AVLIS process uses laser energy to selectively photoionize and electrostatically separate plutonium isotopes from an atomic vapor stream. The MLIS process uses laser energy to selectively disassociate specific isotopes of plutonium in the form of PuF/sub 6/ molecules to create PuF/sub 5/ for collection and further processing. Both processes produce plutonium metal as their product. An evaluation of differences in potential environmental impacts attributed to the construction of an SIS facility, based on either technology, included a comparison of construction materials, land areas required, and the size of the design and construction workforce. The differences in potential environmental impacts from operating an SIS facility were also compared. No large differences in potential environmental impacts would be expected from the use of process chemicals. An AVLIS or an MLIS facility would produce operating effluents that would meet all applicable radiation, chemical, and hazardous waste standards and would be constructed to protect workers, the public and the environment. This EA has not revealed any significant differences in the potential environmental impacts that could occur as a result of deploying either the AVLIS or the MLIS Special Isotope Separation technology.

  1. Synthesis of alpha-amino acids

    DOE Patents [OSTI]

    Davis, J.W. Jr.

    1983-01-25

    A method is described for synthesizing alpha amino acids proceeding through novel intermediates of the formulas: R[sub 1]R[sub 2]C(OSOCl)CN, R[sub 1]R[sub 2]C(Cl)CN and [R[sub 1]R[sub 2]C(CN)O][sub 2]SO wherein R[sub 1] and R[sub 2] are each selected from hydrogen monovalent substituted and unsubstituted hydrocarbon radicals of 1 to 10 carbon atoms. The use of these intermediates allows the synthesis steps to be exothermic and results in an overall synthesis method which is faster than the synthesis methods of the prior art. No Drawings

  2. Use of LEU in the aqueous homogeneous medical isotope production reactor

    SciTech Connect (OSTI)

    Ball, R.M.

    1997-08-01

    The Medical Isotope Production Reactor (MIPR) is an aqueous solution of uranyl nitrate in water, contained in an aluminum cylinder immersed in a large pool of water which can provide both shielding and a medium for heat exchange. The control rods are inserted at the top through re-entrant thimbles. Provision is made to remove radiolytic gases and recombine emitted hydrogen and oxygen. Small quantities of the solution can be continuously extracted and replaced after passing through selective ion exchange columns, which are used to extract the desired products (fission products), e.g. molybdenum-99. This reactor type is known for its large negative temperature coefficient, the small amount of fuel required for criticality, and the ease of control. Calculation using TWODANT show that a 20% U-235 enriched system, water reflected can be critical with 73 liters of solution.

  3. High efficiency and brightness fluorescent organic light emitting diode by triplet-triplet fusion

    DOE Patents [OSTI]

    Forrest, Stephen; Zhang, Yifan

    2015-02-10

    A first device is provided. The first device further comprises an organic light emitting device. The organic light emitting device further comprises an anode, a cathode, and an emissive layer disposed between the anode and the cathode. The emissive layer may include an organic host compound and at least one organic emitting compound capable of fluorescent emission at room temperature. Various configurations are described for providing a range of current densities in which T-T fusion dominates over S-T annihilation, leading to very high efficiency fluorescent OLEDs.

  4. Demonstration Assessment of Light-Emitting Diode (LED) Post-Top Lighting at

    Office of Scientific and Technical Information (OSTI)

    Central Park in New York City (Technical Report) | SciTech Connect Demonstration Assessment of Light-Emitting Diode (LED) Post-Top Lighting at Central Park in New York City Citation Details In-Document Search Title: Demonstration Assessment of Light-Emitting Diode (LED) Post-Top Lighting at Central Park in New York City A review of five post-top light-emitting diode (LED) pedestrian luminaires installed in New York City's Central Park for possible replacement to the existing metal halide

  5. Metathesis process for preparing an alpha, omega-functionalized olefin

    DOE Patents [OSTI]

    Burdett, Kenneth A.; Mokhtarzadeh, Morteza; Timmers, Francis J.

    2010-10-12

    A cross-metathesis process for preparing an .alpha.,.omega.-functionalized olefin, such as methyl 9-decenoate, and an .alpha.-olefin having three or more carbon atoms, such as 1-decene. The process involves contacting in a first reaction zone an .alpha.-functionalized internal olefin, such as methyl oleate, and an .alpha.-olefinic monomer having three or more carbon atoms, such as 1-decene, with a first metathesis catalyst to prepare an effluent stream containing the .alpha.,.omega.-functionalized olefin, such as methyl 9-decenoate, an unfunctionalized internal olefin, such as 9-octadecene, unconverted reactant olefins, and optionally, an .alpha.,.omega.-difunctionalized internal olefinic dimer, such as dimethyl 9-octadecen-1,18-dioate; separating said effluent streams; then contacting in a second reaction zone the unfunctionalized internal olefin with ethylene in the presence of a second metathesis catalyst to obtain a second product effluent containing the .alpha.-olefinic monomer having three or more carbon atoms; and cycling a portion of the .alpha.-olefinic monomer stream(s) to the first zone.

  6. Method for using a yeast alpha-amylase promoter

    DOE Patents [OSTI]

    Gao, Johnway; Skeen, Rodney S.; Hooker, Brian S.; Anderson, Daniel B.

    2003-04-22

    The present invention provides the promoter clone discovery of an alpha-amylase gene of a starch utilizing yeast strain Schwanniomyces castellii. The isolated alpha-amylase promoter is an inducible promoter, which can regulate strong gene expression in starch culture medium.

  7. A simple procedure to prepare spherical {alpha}-alumina powders

    SciTech Connect (OSTI)

    Liu Hongyu [State Key Laboratory of Fine Chemicals, Dalian University of Technology, Dalian 116012 (China); Ning Guiling [State Key Laboratory of Fine Chemicals, Dalian University of Technology, Dalian 116012 (China)], E-mail: ninggl@dlut.edu.cn; Gan Zhihong; Lin Yuan [State Key Laboratory of Fine Chemicals, Dalian University of Technology, Dalian 116012 (China)

    2009-04-02

    Spherical {alpha}-alumina powders were prepared by the controlled hydrolysis of aluminum isopropoxide in a hydrolysis system consisting of octanol and acetonitrile. Diverse solvents to dissolve reactant formed diverse hydrolysis systems and affected particle shape of {alpha}-alumina powders. The precursors crystallized to {gamma}-alumina at 1000 deg. C and converted to {alpha}-alumina at 1150 deg. C without intermediate phases. The particle morphology of precursor was retained after it crystallized to {alpha}-alumina. The heating rate influenced the particle shape and the state of agglomeration during calcination process. The thermal properties of the precursors were characterized by thermal gravimetric and differential thermal analysis. X-ray diffraction technique was used to confirm the conversion of crystalline phase of alumina powders from amorphous to {alpha}-phase. Transmission electron microscopy was used to investigate the morphologies and size of the precursors and products.

  8. TRIFID (TRansuranic Isotopic Fraction Interrogation Device): A second generation plutonium isotopic analysis system

    SciTech Connect (OSTI)

    Fleissner, J G; Coressel, T W; Freier, D A; Macklin, L L

    1989-01-01

    The TRIFID (Transuranic Isotopic Fraction Interrogation Device) system is a second generation plutonium isotopic analysis system which incorporates many new and unique features in the area of isotopic data acquisition and isotopic analysis instrument consisting of a Canberra Series 95-MCA interfaced to a Compaq 386 computer. The entire TRIFID software package, including MCA communications and isotopic analysis routines, was developed using the C programming language. Extensive use has been made of user friendly screens and menus for ease of operation and training and to facilitate use by technical level operators. Automated TRIFID features provide for MCA/ADC setup and acquisition, spectral storage, isotopic analysis, and report generation. One unique feature of the TRIFID system design allows it to be pre-programed for an entire day's counting. The isotopic analysis module (EPICS) contains an expert system formalism which is used to detect and assay for spectral interferences, and to automatically adjust peak fitting constraints based on spectral intensity variations. A TRIFID system has been in operation in a production laboratory at the Rocky Flats Plant since September 1988. Marked decreases in training and hands-on operation time have been achieved in comparison to the older, preceding isotopic systems. 2 refs., 3 figs.

  9. Low-Cost Light-Emitting Diode Luminaire for General Illumination...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    organic light-emitting diode (WOLED) using a single emitter on a planar glass substrate. ... A single-doped WOLED that addresses manufacturing and performance issues can help meet the ...

  10. Diffusion injected multi-quantum well light-emitting diode structure

    SciTech Connect (OSTI)

    Riuttanen, L. Nyknen, H.; Svensk, O.; Suihkonen, S.; Sopanen, M.; Kivisaari, P.; Oksanen, J.; Tulkki, J.

    2014-02-24

    The attention towards light-emitting diode (LED) structures based on nanowires, surface plasmon coupled LEDs, and large-area high-power LEDs has been increasing for their potential in increasing the optical output power and efficiency of LEDs. In this work we demonstrate an alternative way to inject charge carriers into the active region of an LED, which is based on completely different current transport mechanism compared to conventional current injection approaches. The demonstrated structure is expected to help overcoming some of the challenges related to current injection with conventional structures. A functioning III-nitride diffusion injected light-emitting diode structure, in which the light-emitting active region is located outside the pn-junction, is realized and characterized. In this device design, the charge carriers are injected into the active region by bipolar diffusion, which could also be utilized to excite otherwise challenging to realize light-emitting structures.

  11. Adhesion in flexible organic and hybrid organic/inorganic light emitting device and solar cells

    SciTech Connect (OSTI)

    Yu, D.; Kwabi, D.; Akogwu, O.; Du, J.; Oyewole, O. K.; Tong, T.; Anye, V. C.; Rwenyagila, E.; Asare, J.; Fashina, A.; Soboyejo, W. O.

    2014-08-21

    This paper presents the results of an experimental study of the adhesion between bi-material pairs that are relevant to organic light emitting devices, hybrid organic/inorganic light emitting devices, organic bulk heterojunction solar cells, and hybrid organic/inorganic solar cells on flexible substrates. Adhesion between the possible bi-material pairs is measured using force microscopy (AFM) techniques. These include: interfaces that are relevant to organic light emitting devices, hybrid organic/inorganic light emitting devices, bulk heterojunction solar cells, and hybrid combinations of titanium dioxide (TiO{sub 2}) and poly(3-hexylthiophene). The results of AFM measurements are incorporated into the Derjaguin-Muller-Toporov model for the determination of adhesion energies. The implications of the results are then discussed for the design of robust organic and hybrid organic/inorganic electronic devices.

  12. Method and apparatus for improving the performance of light emitting diodes

    DOE Patents [OSTI]

    Lowery, Christopher H.; McElfresh, David K.; Burchet, Steve; Adolf, Douglas B.; Martin, James

    1996-01-01

    A method for increasing the resistance of a light emitting diode and other semiconductor devices to extremes of temperature is disclosed. During the manufacture of the light emitting diode, a liquid coating is applied to the light emitting die after the die has been placed in its lead frame. After the liquid coating has been placed on the die and its lead frames, a thermosetting encapsulant material is placed over the coating. The operation that cures the thermosetting material leaves the coating liquid intact. As the die and the encapsulant expand and contract at different rates with respect to changes in temperature, and as in known light emitting diodes the encapsulating material adheres to the die and lead frames, this liquid coating reduces the stresses that these different rates of expansion and contraction normally cause by eliminating the adherence of the encapsulating material to the die and frame.

  13. Demonstration Assessment of Light-Emitting Diode (LED) Post-Top...

    Office of Scientific and Technical Information (OSTI)

    at Central Park in New York City Citation Details In-Document Search Title: Demonstration Assessment of Light-Emitting Diode (LED) Post-Top Lighting at Central Park in New York ...

  14. Understanding Drooping Light Emitting Diodes CEEM | U.S. DOE Office of

    Office of Science (SC) Website

    Science (SC) Understanding Drooping Light Emitting Diodes CEEM Energy Frontier Research Centers (EFRCs) EFRCs Home Centers Research Science Highlights Highlight Archives News & Events Publications History Contact BES Home 04.27.12 Understanding Drooping Light Emitting Diodes CEEM Print Text Size: A A A FeedbackShare Page Scientific Achievement New calculations demonstrate that LED "droop" is dominated by multi-particle interactions. Droop occurs when increasing energy input

  15. Energy Savings Estimates of Light Emitting Diodes in Niche Lighting Applications

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Estimates of Light Emitting Diodes in Niche Lighting Applications Prepared for: Building Technologies Program Office of Energy Efficiency and Renewable Energy U.S. Department of Energy Prepared by: Navigant Consulting Inc. 1801 K Street, NW Suite 500 Washington DC, 20006 September 2008 * Department of Energy Washington, DC 20585 Energy Savings Estimates of Light Emitting Diodes in Niche Lighting Applications Released: September 2008 Revised: October 2008 This DOE report presents research

  16. Integration of photoactive and electroactive components with vertical cavity surface emitting lasers

    DOE Patents [OSTI]

    Bryan, Robert P.; Esherick, Peter; Jewell, Jack L.; Lear, Kevin L.; Olbright, Gregory R.

    1997-01-01

    A monolithically integrated optoelectronic device is provided which integrates a vertical cavity surface emitting laser and either a photosensitive or an electrosensitive device either as input or output to the vertical cavity surface emitting laser either in parallel or series connection. Both vertical and side-by-side arrangements are disclosed, and optical and electronic feedback means are provided. Arrays of these devices can be configured to enable optical computing and neural network applications.

  17. Integration of photoactive and electroactive components with vertical cavity surface emitting lasers

    DOE Patents [OSTI]

    Bryan, R.P.; Esherick, P.; Jewell, J.L.; Lear, K.L.; Olbright, G.R.

    1997-04-29

    A monolithically integrated optoelectronic device is provided which integrates a vertical cavity surface emitting laser and either a photosensitive or an electrosensitive device either as input or output to the vertical cavity surface emitting laser either in parallel or series connection. Both vertical and side-by-side arrangements are disclosed, and optical and electronic feedback means are provided. Arrays of these devices can be configured to enable optical computing and neural network applications. 9 figs.

  18. High-Efficiency and Stable White Organic Light-Emitting Diode Using a

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Single Emitter | Department of Energy and Stable White Organic Light-Emitting Diode Using a Single Emitter High-Efficiency and Stable White Organic Light-Emitting Diode Using a Single Emitter Lead Performer: Arizona State University - Tempe, AZ DOE Total Funding: $664,785 Cost Share: $170,547 Project Term: 10/1/2011 - 9/30/2015 Funding Opportunity: Solid State Lighting Core Technology Funding Opportunity Announcement (DE-FOA- 0000329) Project Objective This project will demonstrate an

  19. DOE Science Showcase - Light-emitting Diode (LED) Lighting Research | OSTI,

    Office of Scientific and Technical Information (OSTI)

    US Dept of Energy Office of Scientific and Technical Information Light-emitting Diode (LED) Lighting Research Light-emitting diode (LED) lighting is a type of solid-state lighting that uses a semiconductor to convert electricity to light. LED lighting products are beginning to appear in a wide variety of home, business, and industrial products such as holiday lighting, replacement bulbs for incandescent lamps, street lighting, outdoor area lighting and indoor ambient lighting. Over the past

  20. Antihydrogen Trapped in the ALPHA Experiment

    ScienceCinema (OSTI)

    None

    2011-04-25

    In 2010 the ALPHA collaboration succeeded in trapping antihydrogen atoms for the first time.[i]  Stored antihydrogen promises to be a unique tool for making high precision measurements of the structure of this first anti-atom. Achieving this milestone presented several substantial experimental challenges and this talk will describe how they were overcome.   The unique design features of the ALPHA apparatus will be explained.[ii]  These allow a high intensity positron source and an antiproton imaging detector similar to the one used in the ATHENA[iii] experiment to be combined with an innovative magnet design of the anti-atom trap. This seeks to minimise the perturbations to trapped charged particles which may cause particle loss and heating[iv].   The diagnostic techniques used to measure the diameter, number, density, and temperatures of both plasmas will be presented as will the methods developed to actively compress and cool of both plasma species to sizes and temperatures [v],[vi], [vii] where trapping attempts with a reasonable chance of success can be tried.   The results of the successful trapping experiments will be outlined as well as some subsequent experiments to improve the trapping rate and storage time. [i] 'Trapped antihydrogen' G.B. Andresen et al., Nature 468, 673 (2010) [ii]'A Magnetic Trap for Antihydrogen Confinement' W. Bertsche et al., Nucl. Instr. Meth. Phys. Res. A566, 746 (2006) [iii] Production and detection of cold antihydrogen atoms M.Amoretti et al., Nature 419, 456 (2002). [iv]' Antihydrogen formation dynamics in a multipolar neutral anti-atom trap' G.B. Andresen et al., Phys. Lett. B 685, 141 (2010) [v]' Evaporative Cooling of Antiprotons to Cryogenic Temperatures',                                   G.B. Andresen et al. Phys. Rev. Lett 105, 013003 (2010) [vi]'Compression of Antiproton Clouds for Antihydrogen Trapping' G. B. Andresen et al. Phys. Rev. Lett 100, 203401 (2008) [vii]  'Autoresonant

  1. Laser Isotope Separation Employing Condensation Repression

    SciTech Connect (OSTI)

    Eerkens, Jeff W.; Miller, William H.

    2004-09-15

    Molecular laser isotope separation (MLIS) techniques using condensation repression (CR) harvesting are reviewed and compared with atomic vapor laser isotope separation (AVLIS), gaseous diffusion (DIF), ultracentrifuges (UCF), and electromagnetic separations (EMS). Two different CR-MLIS or CRISLA (Condensation Repression Isotope Separation by Laser Activation) approaches have been under investigation at the University of Missouri (MU), one involving supersonic super-cooled free jets and dimer formation, and the other subsonic cold-wall condensation. Both employ mixtures of an isotopomer (e.g. {sup i}QF{sub 6}) and a carrier gas, operated at low temperatures and pressures. Present theories of VT relaxation, dimerization, and condensation are found to be unsatisfactory to explain/predict experimental CRISLA results. They were replaced by fundamentally new models that allow ab-initio calculation of isotope enrichments and predictions of condensation parameters for laser-excited and non-excited vapors which are in good agreement with experiment. Because of supersonic speeds, throughputs for free-jet CRISLA are a thousand times higher than cold-wall CRISLA schemes, and thus preferred for large-quantity Uranium enrichments. For small-quantity separations of (radioactive) medical isotopes, the simpler coldwall CRISLA method may be adequate.

  2. Diffusion in silicon isotope heterostructures

    SciTech Connect (OSTI)

    Silvestri, Hughes Howland

    2004-05-14

    The simultaneous diffusion of Si and the dopants B, P, and As has been studied by the use of a multilayer structure of isotopically enriched Si. This structure, consisting of 5 pairs of 120 nm thick natural Si and {sup 28}Si enriched layers, enables the observation of {sup 30}Si self-diffusion from the natural layers into the {sup 28}Si enriched layers, as well as dopant diffusion from an implanted source in an amorphous Si cap layer, via Secondary Ion Mass Spectrometry (SIMS). The dopant diffusion created regions of the multilayer structure that were extrinsic at the diffusion temperatures. In these regions, the Fermi level shift due to the extrinsic condition altered the concentration and charge state of the native defects involved in the diffusion process, which affected the dopant and self-diffusion. The simultaneously recorded diffusion profiles enabled the modeling of the coupled dopant and self-diffusion. From the modeling of the simultaneous diffusion, the dopant diffusion mechanisms, the native defect charge states, and the self- and dopant diffusion coefficients can be determined. This information is necessary to enhance the physical modeling of dopant diffusion in Si. It is of particular interest to the modeling of future electronic Si devices, where the nanometer-scale features have created the need for precise physical models of atomic diffusion in Si. The modeling of the experimental profiles of simultaneous diffusion of B and Si under p-type extrinsic conditions revealed that both species are mediated by neutral and singly, positively charged Si self-interstitials. The diffusion of As and Si under extrinsic n-type conditions yielded a model consisting of the interstitialcy and vacancy mechanisms of diffusion via singly negatively charged self-interstitials and neutral vacancies. The simultaneous diffusion of P and Si has been modeled on the basis of neutral and singly negatively charged self-interstitials and neutral and singly positively charged P

  3. Rossi alpha Measurements and Calculations for HEU/Pb Core (Technical...

    Office of Scientific and Technical Information (OSTI)

    Rossi alpha Measurements and Calculations for HEUPb Core Citation Details In-Document Search Title: Rossi alpha Measurements and Calculations for HEUPb Core You are accessing ...

  4. Apparatus for separating and recovering hydrogen isotopes

    DOE Patents [OSTI]

    Heung, Leung K.

    1994-01-01

    An apparatus for recovering hydrogen and separating its isotopes. The apparatus includes a housing bearing at least a fluid inlet and a fluid outlet. A baffle is disposed within the housing, attached thereto by a bracket. A hollow conduit is coiled about the baffle, in spaced relation to the baffle and the housing. The coiled conduit is at least partially filled with a hydride. The hydride can be heated to a high temperature and cooled to a low temperature quickly by circulating a heat transfer fluid in the housing. The spacing between the baffle and the housing maximizes the heat exchange rate between the fluid in the housing and the hydride in the conduit. The apparatus can be used to recover hydrogen isotopes (protium, deuterium and tritium) from gaseous mixtures, or to separate hydrogen isotopes from each other.

  5. ARM - Evaluation Product - LASSO Alpha 1 Data Bundles

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ProductsLASSO Alpha 1 Data Bundles ARM Data Discovery Browse Data Documentation Use the Data File Inventory tool to view data availability at the file level. Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Evaluation Product : LASSO Alpha 1 Data Bundles [ ARM research - evaluation data product ] The Alpha 1 release contains initial data bundles from the large-eddy simulation (LES) ARM Symbiotic Simulation and Observation (LASSO) workflow pilot

  6. Single and double grid long-range alpha detectors

    DOE Patents [OSTI]

    MacArthur, Duncan W.; Allander, Krag S.

    1993-01-01

    Alpha particle detectors capable of detecting alpha radiation from distant sources. In one embodiment, a voltage is generated in a single electrically conductive grid while a fan draws air containing air molecules ionized by alpha particles through an air passage and across the conductive grid. The current in the conductive grid can be detected and used for measurement or alarm. Another embodiment builds on this concept and provides an additional grid so that air ions of both polarities can be detected. The detector can be used in many applications, such as for pipe or duct, tank, or soil sample monitoring.

  7. Single and double grid long-range alpha detectors

    DOE Patents [OSTI]

    MacArthur, D.W.; Allander, K.S.

    1993-03-16

    Alpha particle detectors capable of detecting alpha radiation from distant sources. In one embodiment, a voltage is generated in a single electrically conductive grid while a fan draws air containing air molecules ionized by alpha particles through an air passage and across the conductive grid. The current in the conductive grid can be detected and used for measurement or alarm. Another embodiment builds on this concept and provides an additional grid so that air ions of both polarities can be detected. The detector can be used in many applications, such as for pipe or duct, tank, or soil sample monitoring.

  8. Selective flow path alpha particle detector and method of use

    DOE Patents [OSTI]

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore

    2002-01-01

    A method and apparatus for monitoring alpha contamination are provided in which ions generated in the air surrounding the item, by the passage of alpha particles, are moved to a distant detector location. The parts of the item from which ions are withdrawn can be controlled by restricting the air flow over different portions of the apparatus. In this way, detection of internal and external surfaces separately, for instance, can be provided. The apparatus and method are particularly suited for use in undertaking alpha contamination measurements during the commissioning operations.

  9. Isotopic abundance in atom trap trace analysis

    DOE Patents [OSTI]

    Lu, Zheng-Tian; Hu, Shiu-Ming; Jiang, Wei; Mueller, Peter

    2014-03-18

    A method and system for detecting ratios and amounts of isotopes of noble gases. The method and system is constructed to be able to measure noble gas isotopes in water and ice, which helps reveal the geological age of the samples and understand their movements. The method and system uses a combination of a cooled discharge source, a beam collimator, a beam slower and magneto-optic trap with a laser to apply resonance frequency energy to the noble gas to be quenched and detected.

  10. Laser isotope separation by multiple photon absorption

    DOE Patents [OSTI]

    Robinson, C. Paul; Rockwood, Stephen D.; Jensen, Reed J.; Lyman, John L.; Aldridge, III, Jack P.

    1987-01-01

    Multiple photon absorption from an intense beam of infrared laser light may be used to induce selective chemical reactions in molecular species which result in isotope separation or enrichment. The molecular species must have a sufficient density of vibrational states in its vibrational manifold that, is the presence of sufficiently intense infrared laser light tuned to selectively excite only those molecules containing a particular isotope, multiple photon absorption can occur. By this technique, for example, intense CO.sub.2 laser light may be used to highly enrich .sup.34 S in natural SF.sub.6 and .sup.11 B in natural BCl.sub.3.

  11. Laser isotope separation by multiple photon absorption

    DOE Patents [OSTI]

    Robinson, C. Paul; Rockwood, Stephen D.; Jensen, Reed J.; Lyman, John L.; Aldridge, III, Jack P.

    1977-01-01

    Multiple photon absorption from an intense beam of infrared laser light may be used to induce selective chemical reactions in molecular species which result in isotope separation or enrichment. The molecular species must have a sufficient density of vibrational states in its vibrational manifold that, in the presence of sufficiently intense infrared laser light tuned to selectively excite only those molecules containing a particular isotope, multiple photon absorption can occur. By this technique, for example, intense CO.sub.2 laser light may be used to highly enrich .sup.34 S in natural SF.sub.6 and .sup.11 B in natural BCl.sub.3.

  12. Laser isotope separation by multiple photon absorption

    DOE Patents [OSTI]

    Robinson, C.P.; Rockwood, S.D.; Jensen, R.J.; Lyman, J.L.; Aldridge, J.P. III.

    1987-04-07

    Multiple photon absorption from an intense beam of infrared laser light may be used to induce selective chemical reactions in molecular species which result in isotope separation or enrichment. The molecular species must have a sufficient density of vibrational states in its vibrational manifold that, is the presence of sufficiently intense infrared laser light tuned to selectively excite only those molecules containing a particular isotope, multiple photon absorption can occur. By this technique, for example, intense CO[sub 2] laser light may be used to highly enrich [sup 34]S in natural SF[sub 6] and [sup 11]B in natural BCl[sub 3]. 8 figs.

  13. Principles of isotope geology. Second edition

    SciTech Connect (OSTI)

    Faure, G.

    1986-01-01

    This is a text in isotope geology/geoscience that integrates material taught in various courses into a unified picture of the earth sciences. It presents an exposition of the principles used in the interpretation of isotopic data and shows how such interpretations apply to the solution of geological problems. References up to 1985 are included with chapters in this edition. New chapters on Sm-Nd, Lu-Hf Re-Os, and K-Ca decay schemes and cosmogenic radionuclides have been added. Data summaries and references have been expanded.

  14. Overview of the U.S. Department of Energy's Isotope Programs

    SciTech Connect (OSTI)

    Carty, J.

    2004-10-05

    This presentation provides an overview of the U.S. Department of Energy's Isotopes Program. The charter of the Isotope Programs covers the production and sale of radioactive and stable isotopes, associated byproducts, surplus materials, and related isotope services.

  15. Synthesis of rutherfordium isotopes in the {sup 238}U({sup 26}Mg, xn){sup 264-x}Rf reaction and study of their decay properties

    SciTech Connect (OSTI)

    Gates, J. M.; Garcia, M. A.; Dragojevic, I.; Folden, C. M. III; Nelson, S. L.; Nitsche, H.; Gregorich, K. E.; Stavsetra, L.; Sudowe, R.; Duellmann, Ch. E.; Dvorak, J.; Tuerler, A.; Eichler, R.; Loveland, W.; Pang, G. K.

    2008-03-15

    Isotopes of rutherfordium ({sup 258-261}Rf) were produced in irradiations of {sup 238}U targets with {sup 26}Mg beams. Excitation functions were measured for the 4n,5n, and 6n exit channels. Production of {sup 261}Rf in the 3n exit channel with a cross section of 28{sub -26}{sup +92} pb was observed. {alpha}-decay of {sup 258}Rf was observed for the first time with an {alpha}-particle energy of 9.05 {+-} 0.03 MeV and an {alpha}/total-decay branching ratio of 0.31 {+-} 0.11. In {sup 259}Rf, the electron capture/total-decay branching ratio was measured to be 0.15{+-}0.04. The measured half-lives for {sup 258}Rf, {sup 259}Rf, and {sup 260}Rf were 14.7{sub -1.0}{sup +1.2} ms, 2.5{sub -0.3}{sup +0.4} s, and 22.2{sub -2.4}{sup +3.0} ms, respectively, in agreement with literature data. The systematics of the {alpha}-decay Q-values and of the partial spontaneous fission half-lives were evaluated for even-even nuclides in the region of the N=152,Z=100 deformed shell. The influence of the N=152 shell on the {alpha}-decay Q-values for rutherfordium was observed to be similar to that of the lighter elements (96{<=}Z{<=}102). However, the N=152 shell does not stabilize the rutherfordium isotopes against spontaneous fission, as it does in the lighter elements (96{<=}Z{<=}102)

  16. Method for production of an isotopically enriched compound

    DOE Patents [OSTI]

    Watrous, Matthew G.

    2012-12-11

    A method is presented for producing and isolating an isotopically enriched compound of a desired isotope from a parent radionuclide. The method includes forming, or placing, a precipitate containing a parent radionuclide of the desired daughter isotope in a first reaction zone and allowing sufficient time for the parent to decay into the desired gaseous daughter radioisotope. The method further contemplates collecting the desired daughter isotope as a solid in a second reaction zone through the application of temperatures below the freezing point of the desired isotope to a second reaction zone that is connected to the first reaction zone. Specifically, a method is presented for producing isotopically enriched compounds of xenon, including the radioactive isotope Xe-131m and the stable isotope Xe-131.

  17. Motivation for New Measurements on 241, 242, 243Am Isotopes ...

    Office of Scientific and Technical Information (OSTI)

    Motivation for New Measurements on 241, 242, 243Am Isotopes Citation Details In-Document Search Title: Motivation for New Measurements on 241, 242, 243Am Isotopes The initial ...

  18. Ion laser isotope enrichment by photo-predissociation of formaldehyde

    DOE Patents [OSTI]

    Marling, John B.

    1977-06-17

    Enrichment of carbon, hydrogen and/or oxygen isotopes by means of isotopically selective photo-predissociation of formaldehyde is achieved by irradiation with a fixed frequency ion laser, specifically, a neon, cadmium, or xenon ion laser.

  19. Report of Survey of Oak Ridge Isotope Enrichment (Calutron) Facility...

    Office of Environmental Management (EM)

    Report of Survey of Oak Ridge Isotope Enrichment (Calutron) Facility Building 9204-3 Report of Survey of Oak Ridge Isotope Enrichment (Calutron) Facility Building 9204-3 The ...

  20. OSTIblog Articles in the High Flux Isotope Reactor Topic | OSTI...

    Office of Scientific and Technical Information (OSTI)

    High Flux Isotope Reactor Topic The NXS Class of 2014 by Kathy Chambers 19 Nov, 2014 in ... National Laboratory, High Flux Isotope Reactor, National School on Neutron and X-ray ...

  1. Physicist wins early-career award for isotope work

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Physicist wins early-career award for isotope work Physicist wins early-career award for ... of Los Alamos research in isotopes with important new medical advances," said Alan Bishop. ...

  2. Relativistic calculations of isotope shifts in highly charged ions

    SciTech Connect (OSTI)

    Tupitsyn, I.I.; Shabaev, V.M.; Crespo Lopez-Urrutia, J.R.; Soria Orts, R.; Ullrich, J.; Draganic, I.

    2003-08-01

    The isotope shifts of forbidden transitions in Be- and B-like argon ions are calculated. It is shown that only using the relativistic recoil operator can provide a proper evaluation of the mass isotope shift, which strongly dominates over the field isotope shift for the ions under consideration. Comparing the isotope shifts calculated with the current experimental uncertainties indicates very good perspectives for a first test of the relativistic theory of the recoil effect in middle-Z ions.

  3. Isotopic Analysis- Rock At Coso Geothermal Area (1984) | Open...

    Open Energy Info (EERE)

    Home Exploration Activity: Isotopic Analysis- Rock At Coso Geothermal Area (1984) Exploration Activity Details Location Coso Geothermal Area Exploration Technique...

  4. Cancer-fighting treatment gets boost from Isotope Production Facility

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Cancer-fighting treatment gets boost from Isotope Production Facility Cancer-fighting treatment gets boost from Isotope Production Facility New capability expands existing program, creates treatment product in quantity. April 13, 2012 Medical Isotope Work Moves Cancer Treatment Agent Forward Medical Isotope Work Moves Cancer Treatment Agent Forward - Los Alamos scientist Meiring Nortier holds a thorium foil test target for the proof-of-concept production experiments. Research indicates that it

  5. {alpha}-cluster states in N{ne}Z nuclei

    SciTech Connect (OSTI)

    Goldberg, V. Z.; Rogachev, G. V.

    2012-10-20

    The importance of studies of {alpha}-Cluster structure in N{ne}Z light nuclei is discussed. Spin-parity assignments for the low-lying levels in {sup 10}C are suggested.

  6. Alpha heating and burning plasmas in inertial confinement fusion

    SciTech Connect (OSTI)

    Betti, R.; Christopherson, A. R.; Spears, B. K.; Nora, R.; Bose, A.; Howard, J.; Woo, K. M.; Edwards, M. J.; Sanz, J.

    2015-06-01

    Estimating the level of alpha heating and determining the onset of the burning plasma regime is essential to finding the path towards thermonuclear ignition. In a burning plasma, the alpha heating exceeds the external input energy to the plasma. Using a simple model of the implosion, it is shown that a general relation can be derived, connecting the burning plasma regime to the yield enhancement due to alpha heating and to experimentally measurable parameters such as the Lawson ignition parameter. A general alpha-heating curve is found, independent of the target and suitable to assess the performance of all laser fusion experiments whether direct or indirect drive. The onset of the burning plasma regime inside the hot spot of current implosions on the National Ignition Facility requires a fusion yield of about 50 kJ.

  7. Methods of Using Alpha Channeling Together with Transformer Recharging...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Methods of Using Alpha Channeling Together with Transformer Recharging A tokamak current can be sustained using rf waves for transformer recharging at low density and high-Z with...

  8. NREL Releases Alpha-Version of MLife | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Releases Alpha-Version of MLife NREL Releases Alpha-Version of MLife February 24, 2012 - 11:38am Addthis This is an excerpt from the First Quarter 2012 edition of the Wind Program R&D Newsletter. Computer modeling and turbine simulations are important elements of the Department of Energy's (DOE's) Wind Program contributions to the industry's development of next-generation wind turbines. For more than two decades, DOE's National Renewable Energy Laboratory (NREL) has been developing advanced

  9. Producing Linear Alpha Olefins From Biomass - Energy Innovation Portal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Producing Linear Alpha Olefins From Biomass Great Lakes Bioenergy Research Center Contact GLBRC About This Technology Technology Marketing Summary Linear alpha olefins (LAOs) are valuable commodity chemicals traditionally derived from petroleum. They are versatile building blocks for making a range of chemical products like polyethylene, synthetic oils, plasticizers, detergents and oilfield fluids. Relying on fossil fuel to manufacture LAOs is problematic. Not only are the standard methods

  10. Labeled ALPHA4BETA2 ligands and methods therefor

    DOE Patents [OSTI]

    Mukherjee, Jogeshwar; Pichika, Ramaiah; Potkin, Steven; Leslie, Frances; Chattopadhyay, Sankha

    2013-02-19

    Contemplated compositions and methods are employed to bind in vitro and in vivo to an .alpha.4.beta.2 nicotinic acetylcholine receptor in a highly selective manner. Where such compounds are labeled, compositions and methods employing such compounds can be used for PET and SPECT analysis. Alternatively, and/or additionally contemplated compounds can be used as antagonists, partial agonists or agonists in the treatment of diseases or conditions associated with .alpha.4.beta..beta.2 dysfunction.

  11. Small-Molecule Inhibition of TNF-alpha

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Small-Molecule Inhibition of TNF-alpha Tumour necrosis factor is a polypeptide cytokine involved in inflammation and the acute phase response. TNF-alpha is present in larger quantities in persons with rheumatoid arthritis or Crohn's disease. Direct inhibition of TNF-a by the commercial biological agents etanercept (Enbrel), infliximab (Remicade), adalimumab (Humira), has produced significant advances in rheumatoid arthritis treatment and validated the extra-cellular inhibition of this

  12. Discovery of palladium, antimony, tellurium, iodine, and xenon isotopes

    SciTech Connect (OSTI)

    Kathawa, J.; Fry, C.; Thoennessen, M., E-mail: thoennessen@nscl.msu.edu

    2013-01-15

    Currently, thirty-eight palladium, thirty-eight antimony, thirty-nine tellurium, thirty-eight iodine, and forty xenon isotopes have been observed and the discovery of these isotopes is described here. For each isotope a brief synopsis of the first refereed publication, including the production and identification method, is presented.

  13. Synthesis and optical properties of cadmium selenide quantum dots for white light-emitting diode application

    SciTech Connect (OSTI)

    Xu, Xianmei; Wang, Yilin; Gule, Teri; Luo, Qiang [School of Chemistry and Chemical Engineering, Guangxi University, Nanning 53000 (China); Zhou, Liya, E-mail: zhouliyatf@163.com [School of Chemistry and Chemical Engineering, Guangxi University, Nanning 53000 (China); Gong, Fuzhong [School of Chemistry and Chemical Engineering, Guangxi University, Nanning 53000 (China)

    2013-03-15

    Highlights: ? Stable CdSe QDs were synthesized by the one-step and two-level process respectively. ? The fabricated white LEDs show good white balance. ? CdSe QDs present well green to yellow band luminescence. ? CdSe QDs displayed a broad excitation band. - Abstract: Yellow light-emitting cadmium selenide quantum dots were synthesized using one-step and two-step methods in an aqueous medium. The structural luminescent properties of these quantum dots were investigated. The obtained cadmium selenide quantum dots displayed a broad excitation band suitable for blue or near-ultraviolet light-emitting diode applications. White light-emitting diodes were fabricated by coating the cadmium selenide samples onto a 460 nm-emitting indium gallium nitrite chip. Both samples exhibited good white balance. Under a 20 mA working current, the white light-emitting diode fabricated via the one-step and two-step methods showed Commission Internationale de lclairage coordinates at (0.27, 0.23) and (0.27, 0.33), respectively, and a color rendering index equal to 41 and 37, respectively. The one-step approach was simpler, greener, and more effective than the two-step approach. The one-step approach can be enhanced by combining cadmium selenide quantum dots with proper phosphors.

  14. Isotope shifts and nuclear charge radii of krypton isotopes across the N =50 shell closure

    SciTech Connect (OSTI)

    Schuessler, H.A.; Alousi, A.; Evans, R.M.; Brieger, M.; Buchinger, F.; Li, Y.F. Foster Radiation Laboratory, McGill University, Montreal, Quebec )

    1990-09-10

    Optical isotope shifts have been measured in the 5{ital s}(3/2){sub 2}{sup 0}--5{ital p}(3/2){sub 2} transition in atomic krypton ({lambda}=760 nm) using collinear-fast-beam laser spectroscopy. Isotope shifts were determined for the short-lived neutron-rich isotopes {sup 88}Kr and {sup 90}Kr, as well as for all the stable isotopes between {ital A}=78 and 86, thus extending the data in this element, for the first time, beyond the {ital N}=50 shell closure. The deduced changes in the nuclear charge radii show a decrease of the charge radius with increasing neutron number below {ital N}=50, and a much more rapid increase above it. A preliminary interpretation of the results is given in terms of the droplet model.

  15. Preparation and synthetic application of {alpha}-phenylthioethylsamarium compound

    SciTech Connect (OSTI)

    Kasuga, Y.; Matsubara, S.; Utimoto, K. [Kyoto Univ. (Japan)

    1995-12-31

    Although samarium(II) iodide-mediated reaction of organohalides with carbonyl compounds has been applied to various organic syntheses, intermediary organosamarium species could be detected only when HMPA exists in the reaction system. The authors now report the detection of {alpha}-phenylthioethylsamarium compound in the absence of HMPA and application to diastereoselective reaction with aldehydes. A treatment of the organosamarium reagent, prepared from 1-chloroethyl phenyl sulfide and samarium(II) iodide, with D{sub 2}O afforded 1-deuterioethyl phenyl sulfide in 53% yield (82% D). The reagent reacted with aldehyde containing a stereogenic center at {alpha}-position to give {beta}-hydroxysulfide with high diastereoselectivity. Reaction using Barbier type procedure afforded the same results. These results suggest that {alpha}-phenylthioethylsamarium species is also generated in the Barbier type reaction. Configurational stability of {alpha}-thiosubstituted alkylmetal compounds seems to depend on the applied metal. Hoffmann Test indicated that the configuration of {alpha}-phenylthloethylsamarium compound is unchanged during the reaction with aldehyde, while that of {alpha}-alkylthioalkyllithium is unstable.

  16. Laser Isotope Enrichment for Medical and Industrial Applications

    SciTech Connect (OSTI)

    Leonard Bond

    2006-07-01

    Laser Isotope Enrichment for Medical and Industrial Applications by Jeff Eerkens (University of Missouri), Jay Kunze (Idaho State University), and Leonard Bond (Idaho National Laboratory) The principal isotope enrichment business in the world is the enrichment of uranium for commercial power reactor fuels. However, there are a number of other needs for separated isotopes. Some examples are: 1) Pure isotopic targets for irradiation to produce medical radioisotopes. 2) Pure isotopes for semiconductors. 3) Low neutron capture isotopes for various uses in nuclear reactors. 4) Isotopes for industrial tracer/identification applications. Examples of interest to medicine are targets to produce radio-isotopes such as S-33, Mo-98, Mo-100, W-186, Sn-112; while for MRI diagnostics, the non-radioactive Xe-129 isotope is wanted. For super-semiconductor applications some desired industrial isotopes are Si-28, Ga-69, Ge-74, Se-80, Te-128, etc. An example of a low cross section isotope for use in reactors is Zn-68 as a corrosion inhibitor material in nuclear reactor primary systems. Neutron activation of Ar isotopes is of interest in industrial tracer and diagnostic applications (e.g. oil-logging). . In the past few years there has been a sufficient supply of isotopes in common demand, because of huge Russian stockpiles produced with old electromagnetic and centrifuge separators previously used for uranium enrichment. Production of specialized isotopes in the USA has been largely accomplished using old ”calutrons” (electromagnetic separators) at Oak Ridge National Laboratory. These methods of separating isotopes are rather energy inefficient. Use of lasers for isotope separation has been considered for many decades. None of the proposed methods have attained sufficient proof of principal status to be economically attractive to pursue commercially. Some of the authors have succeeded in separating sulfur isotopes using a rather new and different method, known as condensation

  17. Rapid fusion method for the determination of refractory thorium and uranium isotopes in soil samples

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Maxwell, Sherrod L.; Hutchison, Jay B.; McAlister, Daniel R.

    2015-02-14

    Recently, approximately 80% of participating laboratories failed to accurately determine uranium isotopes in soil samples in the U.S Department of Energy Mixed Analyte Performance Evaluation Program (MAPEP) Session 30, due to incomplete dissolution of refractory particles in the samples. Failing laboratories employed acid dissolution methods, including hydrofluoric acid, to recover uranium from the soil matrix. The failures illustrate the importance of rugged soil dissolution methods for the accurate measurement of analytes in the sample matrix. A new rapid fusion method has been developed by the Savannah River National Laboratory (SRNL) to prepare 1-2 g soil sample aliquots very quickly, withmore » total dissolution of refractory particles. Soil samples are fused with sodium hydroxide at 600 ºC in zirconium crucibles to enable complete dissolution of the sample. Uranium and thorium are separated on stacked TEVA and TRU extraction chromatographic resin cartridges, prior to isotopic measurements by alpha spectrometry on cerium fluoride microprecipitation sources. Plutonium can also be separated and measured using this method. Batches of 12 samples can be prepared for measurement in <5 hours.« less

  18. Rapid fusion method for the determination of refractory thorium and uranium isotopes in soil samples

    SciTech Connect (OSTI)

    Maxwell, Sherrod L.; Hutchison, Jay B.; McAlister, Daniel R.

    2015-02-14

    Recently, approximately 80% of participating laboratories failed to accurately determine uranium isotopes in soil samples in the U.S Department of Energy Mixed Analyte Performance Evaluation Program (MAPEP) Session 30, due to incomplete dissolution of refractory particles in the samples. Failing laboratories employed acid dissolution methods, including hydrofluoric acid, to recover uranium from the soil matrix. The failures illustrate the importance of rugged soil dissolution methods for the accurate measurement of analytes in the sample matrix. A new rapid fusion method has been developed by the Savannah River National Laboratory (SRNL) to prepare 1-2 g soil sample aliquots very quickly, with total dissolution of refractory particles. Soil samples are fused with sodium hydroxide at 600 ºC in zirconium crucibles to enable complete dissolution of the sample. Uranium and thorium are separated on stacked TEVA and TRU extraction chromatographic resin cartridges, prior to isotopic measurements by alpha spectrometry on cerium fluoride microprecipitation sources. Plutonium can also be separated and measured using this method. Batches of 12 samples can be prepared for measurement in <5 hours.

  19. A New Kind of Column Materials for Gas Chromatographic Hydrogen Isotope Separation

    SciTech Connect (OSTI)

    Hara, M.; Shima, H.; Akamaru, S.; Abe, T.; Matsuyama, M.; Watanabe, K.

    2005-07-15

    A new kind of materials that can be applied to a gas chromatographic hydrogen isotope separation system was developed to reduce the amount of Pd-Pt alloy required for making the column and to improve the separation efficiency. Pd and Pt were deposited on {alpha}-Al{sub 2}O{sub 3} powder by using a barrel sputtering system. Prepared sample powder was characterized from surface morphology, element distributions on the surface, composition and crystallinity. The characterization showed that a uniform layer of Pd-Pt alloy with expected composition was formed on Al{sub 2}O{sub 3} particles. The crystallinity, however, was poor, but improved after annealing at 1073 K for 2 hours. The hydrogen absorbing behavior was also improved by the annealing. A separation column was prepared from the annealed powder and was subjected to experiments on hydrogen isotope separation. The column of annealed powder gave considerably good separation efficiency around room temperature, in spite that only 0.35 g of Pd-Pt was used for the column. The amount of Pd-Pt alloy used here should be compared to previous results, where 1.5 g of Pd-Pt powder was required for high separation efficiency. The new material was quite effective to reduce the amount of Pd-Pt alloy without compromising the separation efficiency and can give further improvement.

  20. Rapid fusion method for the determination of refractory thorium and uranium isotopes in soil samples

    SciTech Connect (OSTI)

    Maxwell, Sherrod L.; Hutchison, Jay B.; McAlister, Daniel R.

    2015-02-14

    Recently, approximately 80% of participating laboratories failed to accurately determine uranium isotopes in soil samples in the U.S Department of Energy Mixed Analyte Performance Evaluation Program (MAPEP) Session 30, due to incomplete dissolution of refractory particles in the samples. Failing laboratories employed acid dissolution methods, including hydrofluoric acid, to recover uranium from the soil matrix. The failures illustrate the importance of rugged soil dissolution methods for the accurate measurement of analytes in the sample matrix. A new rapid fusion method has been developed by the Savannah River National Laboratory (SRNL) to prepare 1-2 g soil sample aliquots very quickly, with total dissolution of refractory particles. Soil samples are fused with sodium hydroxide at 600 C in zirconium crucibles to enable complete dissolution of the sample. Uranium and thorium are separated on stacked TEVA and TRU extraction chromatographic resin cartridges, prior to isotopic measurements by alpha spectrometry on cerium fluoride microprecipitation sources. Plutonium can also be separated and measured using this method. Batches of 12 samples can be prepared for measurement in <5 hours.

  1. Strontium-isotope stratigraphy of Enewetak Atoll

    SciTech Connect (OSTI)

    Ludwig, K.R.; Halley, R.B.; Simmons, K.R.; Peterman, Z.E.

    1988-02-01

    /sup 87/Sr//sup 86/Sr ratios determined for samples from a 350 m core of Neogene lagoonal, shallow-water limestones from Enewetak Atoll display a remarkably informative trend. Like the recently published data for Deep Sea Drilling Project (DSDP) carbonates, /sup 87/Sr//sup 86/Sr at Enewetak increases monotonically but not smoothly from the early Miocene to the Pleistocene. The data show intervals of little or no change in /sup 87/Sr//sup 86/Sr, punctuated by sharp transitions to lower values toward greater core depths. The sharp transitions correlate with observed solution disconformities caused by periods of subaerial erosion, whereas the intervals of little or no change in /sup 87/Sr//sup 86/Sr correspond to intervals of rapid accumulation of shallow-water carbonate sediments. When converted to numerical ages using the published DSDP 590B trend, the best-resolved time breaks are at 282 m (12.3 to 18.2 Ma missing) and 121.6 m (3.0 to 5.3 Ma missing) below the lagoon floor. At Enewetak, Sr isotopes offer a stratigraphic resolution for these shallow-marine Neogene carbonates comparable to that of nannofossil zonation in deep-sea carbonates (0.3-3 m.y.). In addition, the correlation of times of Sr-isotope breaks at Enewetak with times of rapid Sr-isotope change in the DSDP 590B samples confirms the importance of sea-level changes in the evolution of global-marine Sr isotopes and shows that the Sr-isotope response to sea-level falls is rapid.

  2. {gamma}-ray production by proton and {alpha}-particle induced reactions on {sup 12}C, {sup 16}O, {sup 24}Mg, and Fe

    SciTech Connect (OSTI)

    Belhout, A.; Kiener, J.; Coc, A.; Duprat, J.; Engrand, C.; Fitoussi, C.; Gounelle, M.; Lefebvre-Schuhl, A.; Sereville, N. de; Tatischeff, V.; Thibaud, J.-P.; Chabot, M.; Hammache, F.; Benhabiles-Mezhoud, H.

    2007-09-15

    {gamma}-ray production cross sections for proton and {alpha}-particle interactions with {sup 12}C, {sup 16}O, {sup 24}Mg, and Fe have been measured in the energy range 5-25 MeV with proton beams and 5-40 MeV with {alpha}-particle beams. Isotopically pure foils of {sup 24}Mg and foils of natural isotopical composition of C, MgO, and Fe have been used. {gamma}-ray angular distributions were obtained with five high-purity Ge detectors with bismuth germanate Compton shields placed at angles of 45 deg. to 157.5 deg. Cross sections for more than 50 different {gamma}-ray transitions were extracted, and for many of them no data have been published before. Comparison of present data with data available in the literature shows mostly good to excellent agreement. In addition to the production cross sections, high-statistics, low-background line shapes of the 4.438 MeV {sup 12}C {gamma} ray from inelastic scattering off {sup 12}C and spallation of {sup 16}O were obtained. Comparison with nuclear reaction calculations shows that these data place interesting constraints on nuclear reaction models.

  3. Light emitting diode with high aspect ratio submicron roughness for light extraction and methods of forming

    DOE Patents [OSTI]

    Li, Ting

    2013-08-13

    The surface morphology of an LED light emitting surface is changed by applying a reactive ion etch (RIE) process to the light emitting surface. High aspect ratio, submicron roughness is formed on the light emitting surface by transferring a thin film metal hard-mask having submicron patterns to the surface prior to applying a reactive ion etch process. The submicron patterns in the metal hard-mask can be formed using a low cost, commercially available nano-patterned template which is transferred to the surface with the mask. After subsequently binding the mask to the surface, the template is removed and the RIE process is applied for time duration sufficient to change the morphology of the surface. The modified surface contains non-symmetric, submicron structures having high aspect ratio which increase the efficiency of the device.

  4. Light emitting diode with high aspect ratio submicron roughness for light extraction and methods of forming

    DOE Patents [OSTI]

    Li, Ting

    2011-04-26

    The surface morphology of an LED light emitting surface is changed by applying a reactive ion etch (RIE) process to the light emitting surface. High aspect ratio, submicron roughness is formed on the light emitting surface by transferring a thin film metal hard-mask having submicron patterns to the surface prior to applying a reactive ion etch process. The submicron patterns in the metal hard-mask can be formed using a low cost, commercially available nano-patterned template which is transferred to the surface with the mask. After subsequently binding the mask to the surface, the template is removed and the RIE process is applied for time duration sufficient to change the morphology of the surface. The modified surface contains non-symmetric, submicron structures having high aspect ratio which increase the efficiency of the device.

  5. Color stable white phosphorescent organic light emitting diodes with red emissive electron transport layer

    SciTech Connect (OSTI)

    Wook Kim, Jin; Yoo, Seung Il; Sung Kang, Jin; Eun Lee, Song; Kwan Kim, Young; Hwa Yu, Hyeong; Turak, Ayse; Young Kim, Woo

    2015-06-28

    We analyzed the performance of multi-emissive white phosphorescent organic light-emitting diodes (PHOLEDs) in relation to various red emitting sites of hole and electron transport layers (HTL and ETL). The shift of the recombination zone producing stable white emission in PHOLEDs was utilized as luminance was increased with red emission in its electron transport layer. Multi-emissive white PHOLEDs including the red light emitting electron transport layer yielded maximum external quantum efficiency of 17.4% with CIE color coordinates (−0.030, +0.001) shifting only from 1000 to 10 000 cd/m{sup 2}. Additionally, we observed a reduction of energy loss in the white PHOLED via Ir(piq){sub 3} as phosphorescent red dopant in electron transport layer.

  6. MONITORING SPENT NUCLEAR FUEL REPROCESSING CONDITIONS NON-DESTRUCTIVELY AND IN NEAR-REAL-TIME USING THE MULTI-ISOTOPE PROCESS (MIP) MONITOR

    SciTech Connect (OSTI)

    Orton, Christopher R.; Fraga, Carlos G.; Douglas, Matthew; Christensen, Richard; Schwantes, Jon M.

    2010-05-07

    Researchers from Pacific Northwest National Laboratory and The Ohio State University are working to develop a system for monitoring spent nuclear fuel reprocessing facilities on-line, nondestructively, and in near-real-time. This method, known as the Multi-Isotope Process (MIP) Monitor, is based upon the measurement of distribution patterns of a suite of indicator (radioactive) isotopes present within product and waste streams of a nuclear reprocessing facility. Signatures from these indicator isotopes are monitored on-line by gamma spectrometry and compared, in near-real-time, to patterns representing "normal" process conditions using multivariate pattern recognition software. By targeting gamma-emitting indicator isotopes, the MIP Monitor approach is compatible with the use of small, portable, high-resolution gamma detectors that may be easily deployed throughout an existing facility. In addition, utilization of a suite of radio-elements, including ones with multiple oxidation states, increases the likelihood that attempts to divert material via process manipulation would be detected. Proof-of-principle modeling exercises simulating changes in acid strength have been completed and the results are promising. Laboratory testing is currently under way and significant results are available. Recent experimental results, along with an overview of the method are presented.

  7. THE MULTI-ISOTOPE PROCESS (MIP) MONITOR: A NEAR-REAL-TIME, NON-DESTRUCTIVE, INDICATOR OF SPENT NUCLEAR FUEL REPROCESSING CONDITIONS

    SciTech Connect (OSTI)

    Schwantes, Jon M.; Orton, Christopher R.; Fraga, Carlos G.; Douglas, Matthew; Christensen, Richard

    2010-05-07

    Researchers from Pacific Northwest National Laboratory and The Ohio State University are working to develop a system for monitoring spent nuclear fuel reprocessing facilities on-line, non-destructively, and in near-real-time. This method, known as the Multi-Isotope Process (MIP) Monitor, is based upon the measurement of distribution patterns of a suite of indicator (radioactive) isotopes present within product and waste streams of a nuclear reprocessing facility. Signatures from these indicator isotopes are monitored on-line by gamma spectrometry and compared, in near-real-time, to patterns representing "normal" process conditions using multivariate pattern recognition software. By targeting gamma-emitting indicator isotopes, the MIP Monitor approach is compatible with the use of small, portable, high-resolution gamma detectors that may be easily deployed throughout an existing facility. In addition, utilization of a suite of radio-elements, including ones with multiple oxidation states, increases the likelihood that attempts to divert material via process manipulation would be detected. Proof-of-principle modeling exercises simulating changes in acid strength have been completed and the results are promising. Laboratory validation is currently under way and significant results are available. The latest experimental results, along with an overview of the method will be presented.

  8. Minimal Determinants for Binding Activated G alpha from the Structure of a G alpha i1-Peptide Dimer

    SciTech Connect (OSTI)

    Johnston,C.; Lobanova, E.; Shavkunov, A.; Low, J.; Ramer, J.; Blasesius, R.; Fredericks, Z.; willard, F.; Kuhlman, B.; et al.

    2006-01-01

    G-Proteins cycle between an inactive GDP-bound state and an active GTP-bound state, serving as molecular switches that coordinate cellular signaling. We recently used phage display to identify a series of peptides that bind G{alpha}subunits in a nucleotide-dependent manner [Johnston, C. A., Willard, F. S., Jezyk, M. R., Fredericks, Z., Bodor, E. T., Jones, M. B., Blaesius, R., Watts, V. J., Harden, T. K., Sondek, J., Ramer, J. K., and Siderovski, D. P. (2005) Structure 13, 1069-1080]. Here we describe the structural features and functions of KB-1753, a peptide that binds selectively to GDP{center_dot}AlF{sub 4{sup -}}- and GTP{gamma}S-bound states of G{alpha}{sup i} subunits. KB-1753 blocks interaction of G{alpha}{sub transducin} with its effector, cGMP phosphodiesterase, and inhibits transducin-mediated activation of cGMP degradation. Additionally, KB-1753 interferes with RGS protein binding and resultant GAP activity. A fluorescent KB-1753 variant was found to act as a sensor for activated G{alpha} in vitro. The crystal structure of KB-1753 bound to G{alpha}{sub i1}-GDP{center_dot}AlF{sub 4{sup -}} reveals binding to a conserved hydrophobic groove between switch II and 3 helices and, along with supporting biochemical data and previous structural analyses, supports the notion that this is the site of effector interactions for G{alpha}i subunits.

  9. Method of enhancing selective isotope desorption from metals

    DOE Patents [OSTI]

    Knize, Randall J. (Plainsboro, NJ); Cecchi, Joseph L. (Lawrenceville, NJ)

    1984-01-01

    A method of enhancing the thermal desorption of a first isotope of a diatomic gas from a metal comprises the steps of (a) establishing a partial pressure of a second isotope of the diatomic gas in vicinity of the metal; heating the metal to a temperature such that the first isotope is desorbed from the metal; and reducing the partial pressure of the desorbed first isotope while maintaining the partial pressure of the second isotope substantially constant. The method is especially useful for enhancing the desorption of tritium from the Zr-Al getter in a plasma confinement device.

  10. Enriching stable isotopes: Alternative use for Urenco technology

    SciTech Connect (OSTI)

    Rakhorst, H.; de Jong, P.G.T.; Dawson, P.D.

    1996-12-31

    The International Urenco Group utilizes a technologically advanced centrifuge process to enrich uranium in the fissionable isotope {sup 235}U. The group operates plants in the United Kingdom, the Netherlands, and Germany and currently holds a 10% share of the multibillion dollar world enrichment market. In the early 1990s, Urenco embarked on a strategy of building on the company`s uniquely advanced centrifuge process and laser isotope separation (LIS) experience to enrich nonradioactive isotopes colloquially known as stable isotopes. This paper summarizes the present status of Urenco`s stable isotopes business.

  11. Enhancing the emission directionality of organic light-emitting diodes by using photonic microstructures

    SciTech Connect (OSTI)

    Zhang, Shuyu; Turnbull, Graham A., E-mail: gat@st-andrews.ac.uk, E-mail: idws@st-andrews.ac.uk; Samuel, Ifor D. W., E-mail: gat@st-andrews.ac.uk, E-mail: idws@st-andrews.ac.uk [Organic Semiconductor Centre, SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom)] [Organic Semiconductor Centre, SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom)

    2013-11-18

    We report microstructured organic light-emitting diodes (OLEDs) with directional emission based on efficient solution-processable europium-OLEDs patterned by solvent assisted microcontact molding. The angle dependence of the light emission is characterized for OLEDs with square-array photonic crystals with periods between 275?nm and 335?nm. The microstructured devices have emission patterns strongly modified from the Lambertian emission of planar OLEDs and can approximately double the emitted power in a desired angle range in both s- and p-polarizations. The modified emission is attributed to light diffracted out of the waveguide modes of the OLEDs.

  12. Printed assemblies of ultrathin, microscale inorganic light emitting diodes for deformable and semitransparent displays

    DOE Patents [OSTI]

    Rogers, John A; Nuzzo, Ralph; Kim, Hoon-sik; Brueckner, Eric; Park, Sang Il; Kim, Rak Hwan

    2014-10-21

    Described herein are printable structures and methods for making, assembling and arranging electronic devices. A number of the methods described herein are useful for assembling electronic devices where one or more device components are embedded in a polymer which is patterned during the embedding process with trenches for electrical interconnects between device components. Some methods described herein are useful for assembling electronic devices by printing methods, such as by dry transfer contact printing methods. Also described herein are GaN light emitting diodes and methods for making and arranging GaN light emitting diodes, for example for display or lighting systems.

  13. New red phosphor for near-ultraviolet light-emitting diodes with high color-purity

    SciTech Connect (OSTI)

    Wang, Zhengliang; He, Pei; Wang, Rui; Zhao, Jishou; Gong, Menglian

    2010-02-15

    New red phosphors, Na{sub 5}Eu(MoO{sub 4}){sub 4} doped with boron oxide were prepared by the solid-state reaction. Their structure and photo-luminescent properties were investigated. With the introduction of boron oxide, the red emission intensity of the phosphors under 395 nm excitation is strengthened, with high color-purity (x = 0.673, y = 0.327). The single red light-emitting diode was obtained by combining InGaN chip with the red phosphor, bright red light can be observed by naked eyes from the red light-emitting diodes under a forward bias of 20 mA.

  14. THE ATOMIC WEIGHTS COMMISSION AND ISOTOPIC ABUNDANCE RATIO DETERMINATIONS.

    SciTech Connect (OSTI)

    HOLDEN, N.E.

    2005-08-07

    Following Thomson's discovery of stable isotopes in non-radioactive chemical elements, the derivation of atomic weight values from mass spectrometric measurements of isotopic abundance ratios moved very slowly. Forty years later, only 3 1/2 % of the recommended values were based on mass spectrometric measurements and only 38% in the first half century. It might be noted that two chemical elements (tellurium and mercury) are still based on chemical measurements, where the atomic weight value calculated from the relative isotopic abundance measurement either agrees with the value from the chemical measurement or the atomic weight value calculated from the relative isotopic abundance measurement falls within the uncertainty of the chemical measurement of the atomic weight. Of the 19 chemical elements, whose atomic weight is based on non-corrected relative isotopic abundance measurements, five of these are two isotope systems (indium, iridium, lanthanum, lutetium and tantalum) and one is a three-isotope system (oxygen).

  15. Method of preparing mercury with an arbitrary isotopic distribution

    DOE Patents [OSTI]

    Grossman, Mark W.; George, William A.

    1986-01-01

    This invention provides for a process for preparing mercury with a predetermined, arbitrary, isotopic distribution. In one embodiment, different isotopic types of Hg.sub.2 Cl.sub.2, corresponding to the predetermined isotopic distribution of Hg desired, are placed in an electrolyte solution of HCl and H.sub.2 O. The resulting mercurous ions are then electrolytically plated onto a cathode wire producing mercury containing the predetermined isotopic distribution. In a similar fashion, Hg with a predetermined isotopic distribution is obtained from different isotopic types of HgO. In this embodiment, the HgO is dissolved in an electrolytic solution of glacial acetic acid and H.sub.2 O. The isotopic specific Hg is then electrolytically plated onto a cathode and then recovered.

  16. Method of preparing mercury with an arbitrary isotopic distribution

    DOE Patents [OSTI]

    Grossman, M.W.; George, W.A.

    1986-12-16

    This invention provides for a process for preparing mercury with a predetermined, arbitrary, isotopic distribution. In one embodiment, different isotopic types of Hg[sub 2]Cl[sub 2], corresponding to the predetermined isotopic distribution of Hg desired, are placed in an electrolyte solution of HCl and H[sub 2]O. The resulting mercurous ions are then electrolytically plated onto a cathode wire producing mercury containing the predetermined isotopic distribution. In a similar fashion, Hg with a predetermined isotopic distribution is obtained from different isotopic types of HgO. In this embodiment, the HgO is dissolved in an electrolytic solution of glacial acetic acid and H[sub 2]O. The isotopic specific Hg is then electrolytically plated onto a cathode and then recovered. 1 fig.

  17. Green Light-Emitting Diode Makes Highly Efficient White Light; The Spectrum of Clean Energy Innovation (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2010-06-01

    Fact sheet describing NREL's green light emitting diode that can lead to higher efficiency white light used in indoor lighting applications.

  18. Demonstration Assessment of Light-Emitting Diode Roadway Lighting on the FDR Drive in New York, New York

    SciTech Connect (OSTI)

    Myer, Michael; Hazra, Oindrila; Kinzey, Bruce R.

    2011-12-01

    This a report about a field study of light-emitting diodes street lights by four different manufacturers installed on the FDR Drive in New York City, NY.

  19. Alpha-beta coordination method for collective search

    DOE Patents [OSTI]

    Goldsmith, Steven Y.

    2002-01-01

    The present invention comprises a decentralized coordination strategy called alpha-beta coordination. The alpha-beta coordination strategy is a family of collective search methods that allow teams of communicating agents to implicitly coordinate their search activities through a division of labor based on self-selected roles and self-determined status. An agent can play one of two complementary roles. An agent in the alpha role is motivated to improve its status by exploring new regions of the search space. An agent in the beta role is also motivated to improve its status, but is conservative and tends to remain aggregated with other agents until alpha agents have clearly identified and communicated better regions of the search space. An agent can select its role dynamically based on its current status value relative to the status values of neighboring team members. Status can be determined by a function of the agent's sensor readings, and can generally be a measurement of source intensity at the agent's current location. An agent's decision cycle can comprise three sequential decision rules: (1) selection of a current role based on the evaluation of the current status data, (2) selection of a specific subset of the current data, and (3) determination of the next heading using the selected data. Variations of the decision rules produce different versions of alpha and beta behaviors that lead to different collective behavior properties.

  20. Utility of extracting {alpha}-particle energy by waves

    SciTech Connect (OSTI)

    Fisch, N.J.; Herrmann, M.C.

    1994-05-01

    The utility of extracting {alpha}-particle power, and then diverting this power to fast fuel ions, is investigated. As power is diverted to fast ions and then to ions, a number of effects come into play, as the relative amounts of pressure taken up by electrons, fuel ions, and fast {alpha}-particles shift. In addition, if the {alpha}-particle power is diverted to fast fuel ions, there is an enhanced fusion reactivity because of the nonthermal component of the ion distribution. Some useful expressions for describing these effects are derived, and it is shown that fusion reactors with power density about twice what otherwise might be obtained can be contemplated, so long as a substantial amount of the {alpha}-particle power can be diverted. Interestingly, in this mode of operation, once the electron heat is sufficiently confined, further improvement in confinement is actually not desirable. A similar improvement in fusion power density can be obtained for advanced fuel mixtures such as D-He{sup 3}, where the power of both the energetic {alpha}-particles and the energetic protons might be diverted advantageously.

  1. Gross alpha analytical modifications that improve wastewater treatment compliance

    SciTech Connect (OSTI)

    Tucker, B.J.; Arndt, S.

    2007-07-01

    This paper will propose an improvement to the gross alpha measurement that will provide more accurate gross alpha determinations and thus allow for more efficient and cost-effective treatment of site wastewaters. To evaluate the influence of salts that may be present in wastewater samples from a potentially broad range of environmental conditions, two types of efficiency curves were developed, each using a thorium-230 (Th-230) standard spike. Two different aqueous salt solutions were evaluated, one using sodium chloride, and one using salts from tap water drawn from the Bergen County, New Jersey Publicly Owned Treatment Works (POTW). For each curve, 13 to 17 solutions were prepared, each with the same concentration of Th-230 spike, but differing in the total amount of salt in the range of 0 to 100 mg. The attenuation coefficients were evaluated for the two salt types by plotting the natural log of the counted efficiencies vs. the weight of the sample's dried residue retained on the planchet. The results show that the range of the slopes for each of the attenuation curves varied by approximately a factor of 2.5. In order to better ensure the accuracy of results, and thus verify compliance with the gross alpha wastewater effluent criterion, projects depending on gross alpha measurements of environmental waters and wastewaters should employ gross alpha efficiency curves prepared with salts that mimic, as closely as possible, the salt content of the aqueous environmental matrix. (authors)

  2. Hydrogen isotopic exchange over palladium metal

    SciTech Connect (OSTI)

    Carstens, D.H.W.; Encinias, P.D.

    1990-01-01

    We have recently developed the laser-Raman technique as a means of unambiguously measuring the partial pressures of all possible hydrogen isotopes in the gas phase. Using this technique we have investigated the hydrogen-deuterium exchange in a number of metals. This report presents detailed data for isotopic exchange in the palladium hydride system over the temperature range 26{degree}C to -100{degree}C at a pressure of 7 atm. First order kinetic rate constants and activation energies are summarized for the forward (hydride to deuteride) and reverse (deuteride to hydride) exchange processes. In addition, we have found that small amounts (100 ppm) of impurities in the exchange gases considerably slow the exchange kinetics with the effect increasing down the series CH{sub 4}, CO{sub 2}, H{sub 2}O, and CO. 9 refs., 4 figs., 1 tab.

  3. Quantifying uncertainty in stable isotope mixing models

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Davis, Paul; Syme, James; Heikoop, Jeffrey; Fessenden-Rahn, Julianna; Perkins, George; Newman, Brent; Chrystal, Abbey E.; Hagerty, Shannon B.

    2015-05-19

    Mixing models are powerful tools for identifying biogeochemical sources and determining mixing fractions in a sample. However, identification of actual source contributors is often not simple, and source compositions typically vary or even overlap, significantly increasing model uncertainty in calculated mixing fractions. This study compares three probabilistic methods, SIAR [Parnell et al., 2010] a pure Monte Carlo technique (PMC), and Stable Isotope Reference Source (SIRS) mixing model, a new technique that estimates mixing in systems with more than three sources and/or uncertain source compositions. In this paper, we use nitrate stable isotope examples (δ15N and δ18O) but all methods testedmore » are applicable to other tracers. In Phase I of a three-phase blind test, we compared methods for a set of six-source nitrate problems. PMC was unable to find solutions for two of the target water samples. The Bayesian method, SIAR, experienced anchoring problems, and SIRS calculated mixing fractions that most closely approximated the known mixing fractions. For that reason, SIRS was the only approach used in the next phase of testing. In Phase II, the problem was broadened where any subset of the six sources could be a possible solution to the mixing problem. Results showed a high rate of Type I errors where solutions included sources that were not contributing to the sample. In Phase III some sources were eliminated based on assumed site knowledge and assumed nitrate concentrations, substantially reduced mixing fraction uncertainties and lowered the Type I error rate. These results demonstrate that valuable insights into stable isotope mixing problems result from probabilistic mixing model approaches like SIRS. The results also emphasize the importance of identifying a minimal set of potential sources and quantifying uncertainties in source isotopic composition as well as demonstrating the value of additional information in reducing the uncertainty in calculated

  4. Optically pumped isotopic ammonia laser system

    DOE Patents [OSTI]

    Buchwald, Melvin I.; Jones, Claude R.; Nelson, Leonard Y.

    1982-01-01

    An optically pumped isotopic ammonia laser system which is capable of producing a plurality of frequencies in the middle infrared spectral region. Two optical pumping mechanisms are disclosed, i.e., pumping on R(J) and lasing on P(J) in response to enhancement of rotational cascade lasing including stimulated Raman effects, and, pumping on R(J) and lasing on P(J+2). The disclosed apparatus for optical pumping include a hole coupled cavity and a grating coupled cavity.

  5. Stable isotopic analyses in paleoclimatic reconstruction

    SciTech Connect (OSTI)

    Wigand, P.E.

    1995-09-01

    Most traditional paleoclimatic proxy data have inherent time lags between climatic input and system response that constrain their use in accurate reconstruction of paleoclimate chronology, scaling of its variability, and the elucidation of the processes that determine its impact on the biotic and abiotic environment. With the exception of dendroclimatology, and studies of short-lived organisms and pollen recovered from annually varved lacustrine sediments, significant periods of time ranging from years, to centuries, to millennia may intervene between climate change and its first manifestation in paleoclimatic proxy data records. Reconstruction of past climate through changes in plant community composition derived from pollen sequences and plant remains from ancient woodrat middens, wet environments and dry caves all suffer from these lags. However, stable isotopic analyses can provide more immediate indication of biotic response to climate change. Evidence of past physiological response of organisms to changes in effective precipitation as climate varies can be provided by analyses of the stable isotopic content of plant macrofossils from various contexts. These analyses consider variation in the stable isotopic (hydrogen, oxygen and carbon) content of plant tissues as it reflects (1) past global or local temperature through changes in meteoric (rainfall) water chemistry in the case of the first two isotopes, and (2) plant stress through changes in plant respiration/transpiration processes under differing water availability, and varying atmospheric CO, composition (which itself may actually be a net result of biotic response to climate change). Studies currently being conducted in the Intermountain West indicate both long- and short-term responses that when calibrated with modem analogue studies have the potential of revealing not only the timing of climate events, but their direction, magnitude and rapidity.

  6. Separation of uranium isotopes by chemical exchange

    DOE Patents [OSTI]

    Ogle, P.R. Jr.

    1974-02-26

    A chemical exchange method is provided for separating /sup 235/U from / sup 238/U comprising contacting a first phase containing UF/sub 6/ with a second phase containing a compound selected from the group consisting of NOUF/sub 6/, NOUF/sub 7/, and NO/sub 2/UF/sub 7/ until the U Fsub 6/ in the first phase becomes enriched in the /sup 235/U isotope. (Official Gazette)

  7. Quantifying uncertainty in stable isotope mixing models

    SciTech Connect (OSTI)

    Davis, Paul; Syme, James; Heikoop, Jeffrey; Fessenden-Rahn, Julianna; Perkins, George; Newman, Brent; Chrystal, Abbey E.; Hagerty, Shannon B.

    2015-05-19

    Mixing models are powerful tools for identifying biogeochemical sources and determining mixing fractions in a sample. However, identification of actual source contributors is often not simple, and source compositions typically vary or even overlap, significantly increasing model uncertainty in calculated mixing fractions. This study compares three probabilistic methods, SIAR [Parnell et al., 2010] a pure Monte Carlo technique (PMC), and Stable Isotope Reference Source (SIRS) mixing model, a new technique that estimates mixing in systems with more than three sources and/or uncertain source compositions. In this paper, we use nitrate stable isotope examples (?15N and ?18O) but all methods tested are applicable to other tracers. In Phase I of a three-phase blind test, we compared methods for a set of six-source nitrate problems. PMC was unable to find solutions for two of the target water samples. The Bayesian method, SIAR, experienced anchoring problems, and SIRS calculated mixing fractions that most closely approximated the known mixing fractions. For that reason, SIRS was the only approach used in the next phase of testing. In Phase II, the problem was broadened where any subset of the six sources could be a possible solution to the mixing problem. Results showed a high rate of Type I errors where solutions included sources that were not contributing to the sample. In Phase III some sources were eliminated based on assumed site knowledge and assumed nitrate concentrations, substantially reduced mixing fraction uncertainties and lowered the Type I error rate. These results demonstrate that valuable insights into stable isotope mixing problems result from probabilistic mixing model approaches like SIRS. The results also emphasize the importance of identifying a minimal set of potential sources and quantifying uncertainties in source isotopic composition as well as demonstrating the value of additional information in reducing the

  8. Quantifying uncertainty in stable isotope mixing models

    SciTech Connect (OSTI)

    Davis, Paul; Syme, James; Heikoop, Jeffrey; Fessenden-Rahn, Julianna; Perkins, George; Newman, Brent; Chrystal, Abbey E.; Hagerty, Shannon B.

    2015-05-19

    Mixing models are powerful tools for identifying biogeochemical sources and determining mixing fractions in a sample. However, identification of actual source contributors is often not simple, and source compositions typically vary or even overlap, significantly increasing model uncertainty in calculated mixing fractions. This study compares three probabilistic methods, SIAR [Parnell et al., 2010] a pure Monte Carlo technique (PMC), and Stable Isotope Reference Source (SIRS) mixing model, a new technique that estimates mixing in systems with more than three sources and/or uncertain source compositions. In this paper, we use nitrate stable isotope examples (δ15N and δ18O) but all methods tested are applicable to other tracers. In Phase I of a three-phase blind test, we compared methods for a set of six-source nitrate problems. PMC was unable to find solutions for two of the target water samples. The Bayesian method, SIAR, experienced anchoring problems, and SIRS calculated mixing fractions that most closely approximated the known mixing fractions. For that reason, SIRS was the only approach used in the next phase of testing. In Phase II, the problem was broadened where any subset of the six sources could be a possible solution to the mixing problem. Results showed a high rate of Type I errors where solutions included sources that were not contributing to the sample. In Phase III some sources were eliminated based on assumed site knowledge and assumed nitrate concentrations, substantially reduced mixing fraction uncertainties and lowered the Type I error rate. These results demonstrate that valuable insights into stable isotope mixing problems result from probabilistic mixing model approaches like SIRS. The results also emphasize the importance of identifying a minimal set of potential sources and quantifying uncertainties in source isotopic composition as well as demonstrating the value of additional information in reducing the

  9. Concerning the Facility for Rare Isotope Beams

    ScienceCinema (OSTI)

    Symons, James

    2013-05-29

    James Symons, Nuclear Science Division Director at Lawrence Berkeley Lab, and Daniela Leitner, head of operations at Berkeley Lab's 88-Inch Cyclotron, discuss major contributions to the new Facility for Rare Isotope Beams (FRIB) at Michigan State University, including ion source, which will based on the VENUS source built for the 88-Inch Cyclotron, and the GRETA gamma-ray detector now under construction there.

  10. ALPHA SPECTROMETRIC EVALUATION OF SRM-995 AS A POTENTIAL URANIUM/THORIUM DOUBLE TRACER SYSTEM FOR AGE-DATING URANIUM MATERIALS

    SciTech Connect (OSTI)

    Beals, D.

    2011-12-06

    Uranium-233 (t{sub 1/2} {approx} 1.59E5 years) is an artificial, fissile isotope of uranium that has significant importance in nuclear forensics. The isotope provides a unique signature in determining the origin and provenance of uranium-bearing materials and is valuable as a mass spectrometric tracer. Alpha spectrometry was employed in the critical evaluation of a {sup 233}U standard reference material (SRM-995) as a dual tracer system based on the in-growth of {sup 229}Th (t{sub 1/2} {approx} 7.34E3 years) for {approx}35 years following radiochemical purification. Preliminary investigations focused on the isotopic analysis of standards and unmodified fractions of SRM-995; all samples were separated and purified using a multi-column anion-exchange scheme. The {sup 229}Th/{sup 233}U atom ratio for SRM-995 was found to be 1.598E-4 ({+-} 4.50%) using recovery-corrected radiochemical methods. Using the Bateman equations and relevant half-lives, this ratio reflects a material that was purified {approx} 36.8 years prior to this analysis. The calculated age is discussed in contrast with both the date of certification and the recorded date of last purification.

  11. Promising Technology: Retrofit Lights to Light-Emitting Diodes in Refrigerators

    Broader source: Energy.gov [DOE]

    LEDs increase in efficacy at lower temperatures, in contrast with conventional fluorescents. The low temperatures in display cases, therefore, make this an attractive application of LEDs to reduce energy consumption. In addition to saving lighting energy, an LED retrofit can potentially reduce the cooling load in a display case because LEDs emit less heat than do fluorescent bulbs.

  12. Ultra-thin ohmic contacts for p-type nitride light emitting devices

    DOE Patents [OSTI]

    Raffetto, Mark; Bharathan, Jayesh; Haberern, Kevin; Bergmann, Michael; Emerson, David; Ibbetson, James; Li, Ting

    2012-01-03

    A semiconductor based Light Emitting Device (LED) can include a p-type nitride layer and a metal ohmic contact, on the p-type nitride layer. The metal ohmic contact can have an average thickness of less than about 25 .ANG. and a specific contact resistivity less than about 10.sup.-3 ohm-cm.sup.2.

  13. Isotopic noble gas signatures released from medical isotope production facilities - Simulations and measurements

    SciTech Connect (OSTI)

    Saey, Paul R.; Bowyer, Ted W.; Ringbom, Anders

    2010-09-09

    Journal article on the role that radioxenon isotopes play in confirming whether or not an underground explosion was nuclear in nature. Radioxenon isotopes play a major role in confirming whether or not an underground explosion was nuclear in nature. It is then of key importance to understand the sources of environmental radioxenon to be able to distinguish civil sources from those of a nuclear explosion. Based on several years of measurements, combined with advanced atmospheric transport model results, it was recently shown that the main source of radioxenon observations are strong and regular batch releases from a very limited number of medical isotope production facilities. This paper reviews production processes in different medical isotope facilities during which radioxenon is produced. Radioxenon activity concentrations and isotopic compositions are calculated for six large facilities. The results are compared with calculated signals from nuclear explosions. Further, the outcome is compared and found to be consistent with radioxenon measurements recently performed in and around three of these facilities. Some anomalies in measurements in which {sup 131m}Xe was detected were found and a possible explanation is proposed. It was also calculated that the dose rate of the releases is well below regulatory values. Based on these results, it should be possible to better understand, interpret and verify signals measured in the noble gas measurement systems in the International Monitoring of the Comprehensive Nuclear-Test-Ban Treaty.

  14. First AID (Atom counting for Isotopic Determination).

    SciTech Connect (OSTI)

    Roach, J. L.; Israel, K. M.; Steiner, R. E.; Duffy, C. J.; Roench, F. R.

    2002-01-01

    Los Alamos National Laboratory (LANL) has established an in vitro bioassay monitoring program in compliance with the requirements in the Code of Federal Regulations, 10 CFR 835, Occupational Radiation Protection. One aspect of this program involves monitoring plutonium levels in at-risk workers. High-risk workers are monitored using the ultra-sensitive Therrnal Ionization Mass Spectrometry (TIMS) technique to ensure compliance with DOE standards. TIMS is used to measure atom ratios of 239Pua nd 240Puw ith respect to a tracer isotope ('Pu). These ratios are then used to calculate the amount of 239Pu and 240Pup resent. This low-level atom counting technique allows the calculation of the concentration levels of 239Pu and 240Pu in urine for at risk workers. From these concentration levels, dose assessments can be made and worker exposure levels can be monitored. Detection limits for TIMS analysis are on the order of millions of atoms, which translates to activity levels of 150 aCi 239Pua nd 500 aCi for 240Pu. pCi for Our poster presentation will discuss the ultra-sensitive, low-level analytical technique used to measure plutonium isotopes and the data verification methods used for validating isotopic measurements.

  15. Hydrogen isotope separation utilizing bulk getters

    DOE Patents [OSTI]

    Knize, Randall J. (Los Angeles, CA); Cecchi, Joseph L. (Lawrenceville, NJ)

    1990-01-01

    Tritium and deuterium are separated from a gaseous mixture thereof, derived from a nuclear fusion reactor or some other source, by providing a casing with a bulk getter therein for absorbing the gaseous mixture to produce an initial loading of the getter, partially desorbing the getter to produce a desorbed mixture which is tritium-enriched, pumping the desorbed mixture into a separate container, the remaining gaseous loading in the getter being deuterium-enriched, desorbing the getter to a substantially greater extent to produce a deuterium-enriched gaseous mixture, and removing the deuterium-enriched mixture into another container. The bulk getter may comprise a zirconium-aluminum alloy, or a zirconium-vanadium-iron alloy. The partial desorption may reduce the loading by approximately fifty percent. The basic procedure may be extended to produce a multistage isotope separator, including at least one additional bulk getter into which the tritium-enriched mixture is absorbed. The second getter is then partially desorbed to produce a desorbed mixture which is further tritium-enriched. The last-mentioned mixture is then removed from the container for the second getter, which is then desorbed to a substantially greater extent to produce a desorbed mixture which is deuterium-enriched. The last-mentioned mixture is then removed so that the cycle can be continued and repeated. The method of isotope separation is also applicable to other hydrogen isotopes, in that the method can be employed for separating either deuterium or tritium from normal hydrogen.

  16. Hydrogen isotope separation utilizing bulk getters

    DOE Patents [OSTI]

    Knize, Randall J. (Los Angeles, CA); Cecchi, Joseph L. (Lawrenceville, NJ)

    1991-01-01

    Tritium and deuterium are separated from a gaseous mixture thereof, derived from a nuclear fusion reactor or some other source, by providing a casing with a bulk getter therein for absorbing the gaseous mixture to produce an initial loading of the getter, partially desorbing the getter to produce a desorbed mixture which is tritium-enriched, pumping the desorbed mixture into a separate container, the remaining gaseous loading in the getter being deuterium-enriched, desorbing the getter to a substantially greater extent to produce a deuterium-enriched gaseous mixture, and removing the deuterium-enriched mixture into another container. The bulk getter may comprise a zirconium-aluminum alloy, or a zirconium-vanadium-iron alloy. The partial desorption may reduce the loading by approximately fifty percent. The basic procedure may be extended to produce a multistage isotope separator, including at least one additional bulk getter into which the tritium-enriched mixture is absorbed. The second getter is then partially desorbed to produce a desorbed mixture which is further tritium-enriched. The last-mentioned mixture is then removed from the container for the second getter, which is then desorbed to a substantially greater extent to produce a desorbed mixture which is deuterium-enriched. The last-mentioned mixture is then removed so that the cycle can be continued and repeated. The method of isotope separation is also applicable to other hydrogen isotopes, in that the method can be employed for separating either deuterium or tritium from normal hydrogen.

  17. FILTR: Flash Isotope Library and Training Resource

    SciTech Connect (OSTI)

    Campbell, D; Trombino, D

    2007-07-26

    The subject of radiation detection is replete with complex concepts and challenging nomenclature. Furthermore, a daunting variety of radioactive isotopes may be encountered during the routine operation of a radiation detector. Individuals tasked with searching for illicit sources of radiation must remain vigilant while navigating through more frequently encountered mundane and legitimate radioactive sources. The Flash Isotope Library and Training Resource (FILTR) is being developed as an easily accessible and intuitive reference tool to manage the high volume of complex information required for this task. FILTR is an extended version of the Primary Utility for Nuclear Terminology (PUNT) software developed by the Counter Measures Test Beds group at Lawrence Livermore National Laboratory for the United States Secret Service. Authored in the Flash multimedia development environment, FILTR contains detailed information on potentially encountered isotopes as well as training on radiation and operational procedures. Reference material is organized to present critical information quickly while facilitating more in-depth investigation through an intuitive interface and engaging content. FILTR is being developed for a diverse audience of law enforcement organizations and government agencies and a wide range of skill sets from expert analysts to officers whose primary role is not radiation detection. Additionally, the wide compatibility of Flash content will allow FILTR to be readily accessible through the growing number of multi-media enabled electronic devices, including PDAs and cellular phones.

  18. Hydrogen isotope separation utilizing bulk getters

    DOE Patents [OSTI]

    Knize, R.J.; Cecchi, J.L.

    1991-08-20

    Tritium and deuterium are separated from a gaseous mixture thereof, derived from a nuclear fusion reactor or some other source, by providing a casing with a bulk getter therein for absorbing the gaseous mixture to produce an initial loading of the getter, partially desorbing the getter to produce a desorbed mixture which is tritium-enriched, pumping the desorbed mixture into a separate container, the remaining gaseous loading in the getter being deuterium-enriched, desorbing the getter to a substantially greater extent to produce a deuterium-enriched gaseous mixture, and removing the deuterium-enriched mixture into another container. The bulk getter may comprise a zirconium-aluminum alloy, or a zirconium-vanadium-iron alloy. The partial desorption may reduce the loading by approximately fifty percent. The basic procedure may be extended to produce a multistage isotope separator, including at least one additional bulk getter into which the tritium-enriched mixture is absorbed. The second getter is then partially desorbed to produce a desorbed mixture which is further tritium-enriched. The last-mentioned mixture is then removed from the container for the second getter, which is then desorbed to a substantially greater extent to produce a desorbed mixture which is deuterium-enriched. The last-mentioned mixture is then removed so that the cycle can be continued and repeated. The method of isotope separation is also applicable to other hydrogen isotopes, in that the method can be employed for separating either deuterium or tritium from normal hydrogen. 4 figures.

  19. U.S. Department of Energy Isotope Program

    SciTech Connect (OSTI)

    2015-06-23

    The National Isotope Development Center (NIDC) interfaces with the User Community and manages the coordination of isotope production across the facilities and business operations involved in the production, sale, and distribution of isotopes. A virtual center, the NIDC is funded by the Isotope Development and Production for Research and Applications (IDPRA) subprogram of the Office of Nuclear Physics in the U.S. Department of Energy Office of Science. PNNL’s Isotope Program operates in a multi-program category-2 nuclear facility, the Radiochemical Processing Laboratory (RPL), that contains 16 hot cells and 20 gloveboxes. As part of the DOE Isotope Program, the Pacific Northwest National Laboratory dispenses strontium-90, neptunium-237, radium-223, and thorium-227. PNNL’s Isotope Program uses a dedicated hot-cell for strontium-90 dispensing and a dedicated glovebox for radium-223 and thorium-227 dispensing. PNNL’s Isotope Program has access to state of the art analytical equipment in the RPL to support their research and production activities. DOE Isotope Program funded research at PNNL has advanced the application of automated radiochemistry for isotope such as zirconium-89 and astatine-211 in partnership with the University of Washington.

  20. Diffusional exchange of isotopes in a metal hydride sphere.

    SciTech Connect (OSTI)

    Wolfer, Wilhelm G.; Hamilton, John C.; James, Scott Carlton

    2011-04-01

    This report describes the Spherical Particle Exchange Model (SPEM), which simulates exchange of one hydrogen isotope by another hydrogen isotope in a spherical metal hydride particle. This is one of the fundamental physical processes during isotope exchange in a bed of spherical metal particles and is thus one of the key components in any comprehensive physics-based model of exchange. There are two important physical processes in the model. One is the entropy of mixing between the two isotopes; the entropy of mixing is increased by having both isotopes randomly placed at interstitial sites on the lattice and thus impedes the exchange process. The other physical process is the elastic interaction between isotope atoms on the lattice. The elastic interaction is the cause for {beta}-phase formation and is independent of the isotope species. In this report the coupled diffusion equations for two isotopes in the {beta}-phase hydride are solved. A key concept is that the diffusion of one isotope depends not only on its concentration gradient, but also on the concentration gradient of the other isotope. Diffusion rate constants and the chemical potentials for deuterium and hydrogen in the {beta}-phase hydride are reviewed because these quantities are essential for an accurate model of the diffusion process. Finally, a summary of some of the predictions from the SPEM model are provided.