  1. Monitoring of the Airport Calibration Pads at Walker Field, Grand Junction,

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on DeliciousMathematicsEnergyInterested Parties - WAPAEnergy6-09.docAERMOD-PRIME, UnitsMonisha ShahPennsylvania

  2. Airline Passengers' Satisfaction with Airports 

    E-Print Network [OSTI]

    Kim, Hyun Joo

    2012-02-14

    Airports are places where people have the potential to experience either satisfaction or frustration, and marketing and tourism scholars have argued that customer satisfaction is one of the primary goals of airports. However, few studies have...

  3. Congestion delays at hub airports

    E-Print Network [OSTI]

    St. George, Martin J.

    1986-01-01

    A deterministic model was developed to study the effects of inefficient scheduling on flight delays at hub airports. The model bases the delay calculation on published schedule data and on user-defined airport capacities. ...

  4. Philadelphia International Airport Apron Lighting: LED System...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Philadelphia International Airport Apron Lighting: LED System Performance in a Trial Installation Philadelphia International Airport Apron Lighting: LED System Performance in a...

  5. Emergence of secondary airports and dynamics of regional airport systems in the United States

    E-Print Network [OSTI]

    Bonnefoy, Philippe A

    2005-01-01

    With the growing demand for air transportation and limited capacity at major airports, there is a need to increase the capacity of airport systems at the metropolitan area level. The increased use of secondary airports has ...

  6. The impact of airline-airport relations on airport management decisions

    E-Print Network [OSTI]

    Cohen, Dayl Arlene

    1985-01-01

    Airlines, in the past, have had an important influence on airport operations through privileges granted them by the airport lease agreements. Airport administrators and sponsoring agencies have agreed to grant these ...

  7. Denver International Airport Photovoltaic System

    Broader source: Energy.gov [DOE]

    The Denver International Airport (DIA) features a 2-megawatt (MW) photovoltaic (PV) system. DIA also hosts to a second 1.6-MW system. Denver is a Solar America City.

  8. Airport Express Tsuen Wan Line

    E-Print Network [OSTI]

    Edward Rd East Lai King Mei Foo Nam Cheong Prince Edward Mongkok Yau Ma Tei Tsim Sha Tsui East International Airport Tsing Yi Ngau Tau Kok Clear Water Bay Road Chek Lap Kok Lung Cheung Rd Prince

  9. CyclePad Help System CyclePad License

    E-Print Network [OSTI]

    Forbus, Kenneth D.

    of Library Examples of Cycles Simple Steam Rankine Cycle Simple Refrigerator Cycle Basic Gas Turbine Cycle Steam Cycle with Reheat Combined Gas Turbine & Rankine Cycle Basic Engineering Thermodynamics Tables Turbine Compressor Pump Heater Cooler Heat Exchanger Throttle #12;CyclePad Help System 4 Splitter

  10. Implementing Solar Technologies at Airports

    SciTech Connect (OSTI)

    Kandt, A.; Romero, R.

    2014-07-01

    Federal agencies, such as the Department of Defense and Department of Homeland Security, as well as numerous private entities are actively pursuing the installation of solar technologies to help reduce fossil fuel energy use and associated emissions, meet sustainability goals, and create more robust or reliable operations. One potential approach identified for siting solar technologies is the installation of solar energy technologies at airports and airfields, which present a significant opportunity for hosting solar technologies due to large amounts of open land. This report focuses largely on the Federal Aviation Administration's (FAA's) policies toward siting solar technologies at airports.

  11. Airports and Bicycles: what are the obstacles and incentives for operators 1 to improve bicycle access?

    E-Print Network [OSTI]

    Orrick, Phyllis; Frick, Karen Trapenberg

    2013-01-01

    Bicycle Route to Seattle-Tacoma International Airport andRoute Options to Seattle-Tacoma International Airport.International Airport, Seattle-Tacoma International Airport,

  12. ST. LOUIS AIRPORT/ HAZELWOOD INTERIM

    E-Print Network [OSTI]

    processed at the downtown site from 1942 to 1957 under contracts to the Manhattan Engineering District (MED) and later the Atomic Energy Commission (AEC). The transfer of process residues from downtown to sites nearST. LOUIS AIRPORT/ HAZELWOOD INTERIM STORAGE/FUTURA COATINGS CO. MISSOURI EPA ID# MOD980633176 SITE

  13. Calibration Pad Assignments for Spectral Gamma (November 1985) | Department

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p a lCarib Energy (USA) LLCAdministration of theVersion 1.1Dataof

  14. Improving public transportation to Boston Logan International Airport

    E-Print Network [OSTI]

    Cao, Siyuan, M. Eng. Massachusetts Institute of Technology

    2013-01-01

    Boston Logan International Airport is the largest airport in New England and the 1 9 th busiest airport in the United States, serving 29.3 million passengers (arrivals and departures) in 2012. There are approximately 36,900 ...

  15. Tackling uncertainty in airport design : a real options approach

    E-Print Network [OSTI]

    Chambers, Richard-Duane

    2007-01-01

    The airport industry is changing. Once understood as stand-alone public infrastructures, many modern airports now operate within privatized multi-airport systems and contend with previously unknown competitive pressures. ...

  16. Notes 16. Analysis of tilting pad bearings 

    E-Print Network [OSTI]

    San Andres, Luis

    2010-01-01

    affecting tilting pad bearing force coefficients include elastic deformation of the bearing pads and pivots, thermal effects affecting the lubricant viscosity and film clearance, etc. [2,3]. ? Pad Pivot Journal Y X ? Journal speed NOTES 16... is assumed rigid. Journal motion perturbation analysis The bearing supports a static load with components { } YoXo WW , . At speed ?, the static load determines operation with the journal at its static equilibrium position ( YoXo ee ,). At equilibrium...

  17. Sandia Energy - Energy Storage Test Pad (ESTP)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Storage Test Pad (ESTP) Home Energy Permalink Gallery Evaluating Powerful Batteries for Modular Electric Grid Energy Storage Energy, Energy Storage, Energy Storage Systems, Energy...

  18. Siting Solar Photovoltaics at Airports: Preprint

    SciTech Connect (OSTI)

    Kandt, A.; Romero, R.

    2014-06-01

    Airports present a significant opportunity for hosting solar technologies due to their open land; based on a 2010 Federal Aviation Administration study, the US Department of Agriculture, and the US Fish and Wildlife Service, there's potential for 116,704 MW of solar photovoltaics (PV) on idle lands at US airports. PV has a low profile and likely low to no impact on flight operations. This paper outlines guidance for implementing solar technologies at airports and airfields, focusing largely on the Federal Aviation Administration's policies. The paper also details best practices for siting solar at airports, provides information on the Solar Glare Hazard Analysis Tool, and highlights a case study example where solar has been installed at an airport.

  19. Simulation Calibration Autotune Calibration

    E-Print Network [OSTI]

    Wang, Xiaorui "Ray"

    Calibration as Search #12;· EnergyPlus is a desktop app · Writes files during a simulation · Use RAMdisk (mm:ss) Data Size EnergyPlus Simulations 16 18:14 5 GB 64 32 18:19 11 GB 128 64 18:34 22 GB 256 128 18 ... #12;· EnergyPlus ­ 2-10 mins for an annual simulation !- ALL OBJECTS IN CLASS Version, 7.0; !- Version

  20. Multi-modal Transportation > Highway Transportation > Trucking > Railroad transportation > Public transit > Rural transportation > Rural transit > Freight pipeline transportation > Airport planning and development > Airport maintenance > Bicycle and pedes

    E-Print Network [OSTI]

    and development > Airport maintenance > Bicycle and pedestrian > Ports and waterways >>> Transportation operat and development > Airport maintenance > Bicycle and pedestrian > Ports and waterways >>> Transportation operations pipeline transportation > Airport planning and development > Airport maintenance > Bicycle and pedestrian

  1. SEP Success Story: "Green Launching Pad" Supports Clean Energy...

    Energy Savers [EERE]

    "Green Launching Pad" Supports Clean Energy Small Businesses SEP Success Story: "Green Launching Pad" Supports Clean Energy Small Businesses May 24, 2012 - 5:10pm Addthis Green...

  2. Exposure-Rate Calibration Using Large-Area Calibration Pads (September

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum12, 2015Executive Order 13514 Federal Leadership

  3. Modeling Airline Frequency Competition for Airport Congestion Mitigation

    E-Print Network [OSTI]

    Vaze, Vikrant

    Demand often exceeds capacity at congested airports. Airline frequency competition is partially responsible for the growing demand for airport resources. We propose a game-theoretic model for airline frequency competition ...

  4. Value of Options in Airport Expansion - Example of AICM

    E-Print Network [OSTI]

    Morgado, Frederico

    Investments decisions for airport capacity expansion are usually taken, either when demand exceeds the current capacity and the airport is working under congestion, or when current demand is expected to overcome current ...

  5. Analysis of aircraft surface motion at Boston Logan International Airport

    E-Print Network [OSTI]

    Alhanatis, Robert Elias

    The purpose of this thesis is to examine the nature of aircraft surface motion on the airport surface during normal operations. Twelve hours of radar data, gathered by MIT Lincoln Laboratories from Logan airport in Boston, ...

  6. Of airports and architecture : exercises in public form

    E-Print Network [OSTI]

    Fouad, Daniel James

    2006-01-01

    Airports as an architectural and urban typology typically lack physical and spatial integration with their urban context. Contrary to the city, airports have evolved into semi-autonomous spaces and products of political ...

  7. Airport quotas and peak hour pricing : theory and practice

    E-Print Network [OSTI]

    Odoni, Amedeo R.

    1976-01-01

    This report examines the leading theoretical studies not only of airport peak-hour pricing but also of the congestion costs associated with airport delays and presents a consistent formulation of both. The report also ...

  8. Moriarty Municipal Airport (0E0) Pavement Condition and Analysis

    E-Print Network [OSTI]

    Cal, Mark P.

    Airport Development Administrator New Mexico Aviation Division P.O. Box 9830 Albuquerque, NM 87119 tel .................................................................................................................Skid Resistance 13 ....................................................3. Airport Maintenance Completed Assuming No Maintenance 14 ...............Table 5. Predicted Pavement Conditions (PCI) Assuming

  9. Las Cruces International Airport (LRU) Pavement Condition and Analysis

    E-Print Network [OSTI]

    Cal, Mark P.

    , AICP Airport Development Administrator New Mexico Aviation Division P.O. Box 9830 Albuquerque, NM 87119 ........................................................................................................3. Airport Maintenance 14 .......................................4. Predicted Pavement Conditions Assuming No Maintenance 14 ...............Table 4. Predicted Pavement Conditions (PCI) Assuming

  10. Guidelines to improve airport preparedness against chemical and biological terrorism.

    SciTech Connect (OSTI)

    Edwards, Donna M.; Price, Phillip N. (Lawrence Berkeley National Laboratory, Berkeley, CA); Gordon, Susanna P.; Gadgil, Ashok (Lawrence Berkeley National Laboratory, Berkeley, CA)

    2005-05-01

    Guidelines to Improve Airport Preparedness Against Chemical and Biological Terrorism is a 100-page document that makes concrete recommendations on improving security and assessing vulnerable areas and helps its readers understand the nature of chemical and biological attacks. The report has been turned over to Airports Council International (ACI) and the American Association of Airport Executives (AAAE), two organizations that together represent the interests of thousands of airport personnel and facilities in the U.S. and around the world.

  11. Noise Load Management at Amsterdam Airport Schiphol

    E-Print Network [OSTI]

    Boucherie, Richard J.

    Noise Load Management at Amsterdam Airport Schiphol T.R. Meerburg , R.J. Boucherie , M.J.A.L. van objective is to guarantee safety, efficiency, and protection of the environment, that includes noise load contributes to the noise load at these points. If the cumulative load in an aviation year at an enforce- ment

  12. Airport ATC Communications: Procedures and Phraseology

    E-Print Network [OSTI]

    -four cleared for takeoff · Beech eight-delta-mike, after departure, turn left, and proceed direct to the Boiler runway 24 · ... takeoff from runway 10, turn left after takeoff, and fly direct to the BOILER VOR (pick, cleared to Chicago O'Hare Airport, via direct Boiler, victor-seven Chicago Heights, direct 6. King Air

  13. SEP Success Story: Green Launching Pad Taps Six More Companies...

    Energy Savers [EERE]

    Green Launching Pad Taps Six More Companies for Take-off SEP Success Story: Green Launching Pad Taps Six More Companies for Take-off April 29, 2011 - 9:58am Addthis Yesterday, U.S....

  14. A Computational Model for Tilting Pad Journal Bearings with Pad Flexibility 

    E-Print Network [OSTI]

    Li, Yingkun

    2015-07-17

    Tilting pad journal bearings (TPJBs) supporting rotors for high performance turbomachinery have undergone steady design improvements to satisfy more stringent operating conditions that include large specific loads due to smaller footprints, and high...

  15. One-time pad booster for Internet

    E-Print Network [OSTI]

    Geraldo A. Barbosa

    2007-04-11

    One-time pad encrypted files can be sent through Internet channels using current Internet protocols. However, the need for renewing shared secret keys make this method unpractical. This work shows how users can use a fast physical random generator based on fluctuations of a light field and the Internet channel to directly boost key renewals. The transmitted signals are deterministic but carries imprinted noise that cannot be eliminated by the attacker. Thus, a one-time pad for Internet can be made practical. Security is achieved without third parties and not relying on the difficulty of factoring numbers in primes. An informational fragility to be avoided is discussed. Information-theoretic analysis is presented and bounds for secure operation are determined.

  16. Uranium characterization at the St. Louis Airport Site

    SciTech Connect (OSTI)

    Schilk, A.J.; Hubbard, C.W.; Bowyer, T.W. [Pacific Northwest Lab., Richland, WA (United States); Reiman, R.T. [Technical Measurement Co., Boulder, CO (United States)

    1995-05-01

    In support of the Department of Energy/Office of Technology Development`s Expedited Site Characterization (ESC) project (coordinated by Ames Laboratory), the Pacific Northwest Laboratory demonstrated two complementary technologies at the St. Louis Airport (SLAP) site that have been designed and optimized for the rapid, in situ quantification of radionuclide contamination in surface soils. The sensors are optimized for the detection of high-energy beta particles or gamma rays emitted from the decay of specific radionuclides of interest. These technologies were demonstrated by measuring the beta and gamma fluxes at several locations within the SLAP site. Measurements were converted to average contamination levels, using detector calibrations performed with spiked samples (beta) or sealed sources (gamma). Additionally, subsurface activity levels were derived from discrete soil samples (provided by the ESC field crew) via gamma-ray spectrometry in a controlled laboratory setting. Since the beta and gamma sensor technologies are intrinsically sensitive to different types of radiation and activity distributions (i.e., surface and shallow subsurface, respectively), the data obtained from the two detectors provide complementary information about the distribution of the contamination. The results reported here suggest that a number of locations within the SLAP site have elevated levels of {sup 211}U, and the differences between the beta and gamma activities indicate that the contamination is largely located near the surface of the soil.

  17. Evolution and Development of Multi-Airport Systems: A Worldwide Perspective

    E-Print Network [OSTI]

    . This dynamic was driven by the entry of low-cost carriers seizing the opportunity of using existing airport, multi-airport systems have generally evolved through the construction of new high capacity airports, due

  18. EECBG Success Story: New San Antonio Airport Terminal Generating...

    Office of Environmental Management (EM)

    away and the team knew that a solar photovoltaic (PV) system at the airport would offer a highly visible location to showcase renewable energy technologies, help the city...

  19. Metal pad instabilities in liquid metal batteries

    E-Print Network [OSTI]

    Zikanov, Oleg

    2015-01-01

    A mechanical analogy is used to analyze the interaction between the magnetic field, electric current and deformation of interfaces in liquid metal batteries. It is found that, during charging or discharging, a sufficiently large battery is prone to instabilities of two types. One is similar to the metal pad instability known for aluminum reduction cells. Another type is new. It is related to the destabilizing effect of the Lorentz force formed by the azimuthal magnetic field induced by the base current and the current perturbations caused by the local variations of the thickness of the electrolyte layer.

  20. SEP Success Story: "Green Launching Pad" Supports Clean Energy...

    Broader source: Energy.gov (indexed) [DOE]

    New Hampshire Photographic Services A commercialization partnership funded by the State Energy Program - known as the Green Launching Pad program -- is a joint effort by the New...

  1. Prices by Sales Type, PAD District, and Selected States

    Gasoline and Diesel Fuel Update (EIA)

    AdministrationPetroleum Marketing Annual 1999 Table 39. No. 2 Distillate a Prices by Sales Type, PAD District, and Selected States b (Cents per Gallon Excluding Taxes)...

  2. Prices by Sales Type, PAD District, and Selected States

    U.S. Energy Information Administration (EIA) Indexed Site

    AdministrationPetroleum Marketing Annual 1998 Table 39. No. 2 Distillate a Prices by Sales Type, PAD District, and Selected States b (Cents per Gallon Excluding Taxes)...

  3. Vertical Protection Levels for a Local Airport Monitor for WAAS

    E-Print Network [OSTI]

    Stanford University

    they provide acceptable availability, even for a VAL of 10 m. INTRODUCTION The Local Airport Monitor (LAMVertical Protection Levels for a Local Airport Monitor for WAAS Jason Rife, Sam Pullen, Todd Walter development costs for the Local Area Augmentation System (LAAS) have motivated the investigation

  4. FAA Airport Categories Website | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTIONRobertsdale, AlabamaETEC GmbH JumpEllenville,PowerEvaporative CoolersExosunOpenExtremelyFAA Airport

  5. Building Airport Systems for the Next Generation Dealing with the uncertainties of airport development will require new strategies.

    E-Print Network [OSTI]

    Building Airport Systems for the Next Generation Dealing with the uncertainties of airport and passenger buildings, and most travelers know from experience the frequency of aircraft delays, missed skilled and smart people doing their best to make things better, why aren't we getting reasonable results

  6. WSU Professional & Academic Development (PAD) Seminar Series Winter 2015 Offerings

    E-Print Network [OSTI]

    Finley Jr., Russell L.

    for Interdisciplinary Development, Division of Research THU | APRIL 23, 2015 PAD Seminar ­ Conflict Management 1:00pmWSU Professional & Academic Development (PAD) Seminar Series Winter 2015 Offerings The offices this free career development seminar series for WSU faculty, chairs & directors, postdoctoral trainees

  7. Decentralized aircraft landing scheduling at single runway non-controlled airports 

    E-Print Network [OSTI]

    Ding, Yuanyuan

    2009-05-15

    to enhance the transportation capabilities of the small airports in the U.S.A., and distribute the high volume of air traffic at the hub airports to those small airports, which are mostly non-controlled airports. Currently, two major focus areas of research...

  8. Rotordynamic and thermal analyses of compliant flexure pivot tilting pad gas bearings 

    E-Print Network [OSTI]

    Sim, Kyu-Ho

    2009-05-15

    Rotordynamic and thermal analyses of compliant flexure pivot tilting pad gas bearings were performed. First, compliant flexure pivot tilting pad gas bearings with pad radial compliance (CFTPBs) were introduced and designed for high-speed oil...

  9. Measured and Predicted Rotor-Pad Transfer Functions for a Rocker-Pivot Tilting-Pad Journal Bearing 

    E-Print Network [OSTI]

    Wilkes, Jason Christopher

    2012-02-14

    applied to the shaft resulted in a shaft displacement of 25 microns (1 mil), the pad would displace radially 15 microns (0.6 mils), and the fluid film height would only decrease by 10 microns (0.4 mils). The consequence of this pad motion is that fluid...

  10. Rotordynamic coefficients for a load-between-pad, flexible-pivot tilting pad bearing at high loads 

    E-Print Network [OSTI]

    Hensley, John Eric

    2006-10-30

    The dynamic and static performance of a flexure-pivot tilting pad bearing is presented at a load between pad configuration for various load and speed combinations. A similar work performed on the same bearing at lower loads ranging from 0-1 MPa (0...

  11. Transfer passenger needs at airports : human factors in terminal design

    E-Print Network [OSTI]

    Brillembourg, Marie-Claire

    1982-01-01

    This thesis analyzes the needs of particular users of airport: transfer passengers. The object of this work has been to produce a set of design guidelines for terminals. these guidelines are framed upon a user-need survey ...

  12. Hydrogen Production and Dispensing Facility Opens at W. Va. Airport

    Broader source: Energy.gov [DOE]

    A hydrogen production and dispensing station constructed and operated with support from the Office of Fossil Energy's National Energy Technology Laboratory was officially opened Monday at the Yeager Airport in Charleston, W.Va.

  13. A survey of approaches to the airport slot allocation problem

    E-Print Network [OSTI]

    Cohen, Dayl Arlene

    1985-01-01

    Introduction: The allocation of slots at congested major commercial airports is one of the most difficult problems facing the aviation community today. The stakes involved are very large and the controversy generated by ...

  14. New MagViz Airport Liquid Analysis System Undergoes Testing

    ScienceCinema (OSTI)

    None

    2010-01-08

    LOS ALAMOS, New Mexico, December 16, 2008?An innovative application of a technology first used for medical imaging may enhance airport security if Los Alamos National Laboratory scientists are successful. Los Alamos technologists have adapted Magnetic Res

  15. DOE - Office of Legacy Management -- St Louis Airport Site Vicinity...

    Office of Legacy Management (LM)

    been removed from most of the properties and placed in temporary storage at the Hazelwood Interim Storage Site, also known as the Latty Avenue site. The St. Louis Airport Vicinity...

  16. Belen Alexander Municipal Airport (E80) Pavement Condition and Analysis

    E-Print Network [OSTI]

    Cal, Mark P.

    . Lucero, AICP Airport Development Administrator New Mexico Aviation Division P.O. Box 9830 Albuquerque, NM Assuming No Maintenance 13 ..........Table 4. Predicted Pavement Conditions (PCI) Assuming no Maintenance ..............................................................6. Maintenance and Rehabilitation (M&R) Schedule 20

  17. Raton Municipal Airport (RTN) Pavement Condition and Analysis

    E-Print Network [OSTI]

    Cal, Mark P.

    Airport Development Administrator New Mexico Aviation Division P.O. Box 9830 Albuquerque, NM 87119 tel No Maintenance 14 ...............Table 4. Predicted Pavement Conditions (PCI) Assuming no Maintenance After 2007 .......................................................6. Maintenance and Rehabilitation (M&R) Sche

  18. Clayton Municipal Airport (CAO) Pavement Condition and Analysis

    E-Print Network [OSTI]

    Cal, Mark P.

    Airport Development Administrator New Mexico Aviation Division P.O. Box 9830 Albuquerque, NM 87119 tel No Maintenance 13 .....................Table 4. Predicted Pavement Conditions (PCI) Assuming no Maintenance 14 for Runway 12-30 (2010) 20 .......................................................6. Maintenance

  19. Silver City Grant County Airport (SVC) Pavement Condition and Analysis

    E-Print Network [OSTI]

    Cal, Mark P.

    , AICP Airport Development Administrator New Mexico Aviation Division P.O. Box 9830 Albuquerque, NM 87119 No Maintenance 13 ...............Table 4. Predicted Pavement Conditions (PCI) Assuming no Maintenance After 2010 .......................................................6. Maintenance and Rehabilitation (M&R) Schedule 21

  20. Deming Municipal Airport (DMN) Pavement Condition and Analysis

    E-Print Network [OSTI]

    Cal, Mark P.

    Airport Development Administrator New Mexico Aviation Division P.O. Box 9830 Albuquerque, NM 87119 tel No Maintenance 16 2 #12;...............Table 4. Predicted Pavement Conditions (PCI) Assuming no Maintenance After

  1. Sierra Blanca Ruidoso Airport (SRR) Pavement Condition and Analysis

    E-Print Network [OSTI]

    Cal, Mark P.

    , AICP Airport Development Administrator New Mexico Aviation Division P.O. Box 9830 Albuquerque, NM 87119 No Maintenance 13 .................................Table 4. Predicted Pavement Conditions (PCI) Assuming no Maintenance 14 ..........................................Figure 7. Sierra Blanca Ruidoso (SRR) Predicted PCI

  2. Robust decision-support tools for airport surface traffic

    E-Print Network [OSTI]

    Carr, Francis R. (Francis Russell), 1976-

    2004-01-01

    Forecasts of departure demand are one of the driving inputs to tactical decision-support tools (DSTs) for airport surface traffic. While there are well-known results on average- or worst-case forecast uncertainty, it is ...

  3. Robust Decision-Support Tools for Airport Surface Traffic

    E-Print Network [OSTI]

    Carr, Francis R.

    Forecasts of departure demand are one of the driving inputs to tactical decision-support tools (DSTs) for airport surface traffic. While there are well-known results on average- or worst-case forecast uncertainty, it is ...

  4. Roswell International Air Center Airport (ROW) Pavement Condition and Analysis

    E-Print Network [OSTI]

    Cal, Mark P.

    Roswell International Air Center Airport (ROW) Pavement Condition and Analysis Submitted to: Jane M ................................................1. Conditions at Roswell International Air Center (ROW) 4 .................................Figure 1. Geographic Location of Roswell International Air Center (ROW) 4 ..............................Table 1

  5. Mitigating airport congestion : market mechanisms and airline response models

    E-Print Network [OSTI]

    Harsha, Pavithra

    2009-01-01

    Efficient allocation of scarce resources in networks is an important problem worldwide. In this thesis, we focus on resource allocation problems in a network of congested airports. The increasing demand for access to the ...

  6. Airport: Fly into either (SJC) San Jose International Airport (12.2 miles from CHM) or (SFO) San

    E-Print Network [OSTI]

    Geller, Michael R.

    Airport: Fly into either (SJC) San Jose International Airport (12.2 miles from CHM) or (SFO) San.9 miles from CHM) hotel@gardencourt.com Rev: 2/12 San Jose Fairmont Hotel San Jose 170 S. Market Street San Jose, CA 95113 Tel: 408-998-1900 | Fax: 408-287-1648 | Toll free: 866-540-4493 (12.6 miles from

  7. Experimental Investigation of the Padding Tower for Air Dehumidifier 

    E-Print Network [OSTI]

    Wang, J.; Liu, J.; Li, C.; Zhang, G.; An, S.

    2006-01-01

    of the liquid desiccant air conditioning. Of these design parameters, the framework of the padding tower, ratio of the air and the concentration of the inlet solution is largest through the tower, the temperature and effects of the dehumidifying capability...

  8. Experimental frequency-dependent rotordynamic coefficients for a load-on-pad, high-speed, flexible-pivot tilting-pad bearing 

    E-Print Network [OSTI]

    Rodriguez Colmenares, Luis Emigdio

    2004-09-30

    This thesis provides experimental frequency dependent stiffness and damping coefficient results for a high-speed, lightly loaded, flexible-pivot tilting-pad bearing, with a load-on-pad configuration. Test conditions include four shaft speeds (6000...

  9. Estimation and tactical allocation of airport capacity in the presence of uncertainty

    E-Print Network [OSTI]

    Ramanujam, Varun

    2012-01-01

    Major airports in the United States and around the world have seen an increase in congestion-related delays over the past few years. Because airport congestion is caused by an imbalance between available capacity and demand, ...

  10. Evaluation of strategies for reducing taxi-out emissions at airports

    E-Print Network [OSTI]

    Deonandan, Indira

    Aircraft taxiing on the surface contribute significantly to the fuel burn and emissions at airports. This paper is aimed at estimating the baseline fuel burn and emissions from taxi-out processes at airports, evaluating ...

  11. Unaffordable fare : the cost of public transportation for low-income commuters working at three airports

    E-Print Network [OSTI]

    Nadeau, Carey Anne

    2015-01-01

    For airport employers, making sure the many low-income people they employ as baggage handlers and retail salespeople, amongst others, can get to work ensures the continued efficient operations of the airport and the ...

  12. A Decision Support Tool for the Pushback Rate Control of Airport Departures

    E-Print Network [OSTI]

    Sandberg, Melanie J.

    Airport surface congestion control has the potential to mitigate the increase in taxi times and fuel burn at major airports. One possible class of congestion control strategies predicts the departure throughput, and ...

  13. Microfabricated Field Calibration Assembly

    Energy Innovation Portal (Marketing Summaries) [EERE]

    2013-03-19

    Reliable determination of the presence and/or quantity of a particular analyte in the field can be greatly enhanced if the analytical instrument is equipped with a time-of-use calibration standard. While proper calibration is necessary for reliability and accuracy, it can be challenging and cumbersome to provide such calibration in the field using conventional methods found in analytical laboratories....

  14. Pad polishing for rapid production of large flats

    SciTech Connect (OSTI)

    Berggren, R.R.; Schmell, R.A.

    1997-11-01

    Pad polishing is an efficient technique for polishing-out a ground surface and reaching a figure better than one wave, ready for completion with less than an hour on a planetary polisher. For the 350 mm square piece of BK-7, removal was one micrometer every 10 minutes. Polishing-out from a 5 micrometer grind took less than 3 hours, to a surface smoothness of one nm rms. Other tests verified that the pad leaves no unusual subsurface damage. Following completion on a pitch planetary polisher, surface finish is the same as obtained for conventional processing. Unlike pitch, the pad retains its surface figure, producing a uniform result when used on a production basis. Coupled with the speed of production and low capital cost of overarm machines, it provides a cost-effective approach.

  15. Double Eagle II Airport (AEG) Pavement Condition and Analysis

    E-Print Network [OSTI]

    Cal, Mark P.

    .........................................................7. Maintenance and Rehabilitation (M&R) Options 21 ...............Table 9. Current NMDOT-Aviation Airport Development Administrator New Mexico Aviation Division P.O. Box 9830 Albuquerque, NM 87119 tel No Maintenance 11 .....................Table 4. Predicted Pavement Conditions (PCI) Assuming no Maintenance 12

  16. Effort Reporting Professional and Academic Development (PAD) Seminar Series

    E-Print Network [OSTI]

    Finley Jr., Russell L.

    Effort Reporting Professional and Academic Development (PAD) Seminar Series Wednesday, March 2 of the top 100 American research universities. Dan Lodes is a director in Huron's Health and Education for research. The new system will be made available to departmental administrators for review purposes

  17. Roles of discontinuities in bio-inspired adhesive pads

    E-Print Network [OSTI]

    Chaudhury, Manoj K.

    Roles of discontinuities in bio-inspired adhesive pads Jun Young Chung and Manoj K. Chaudhury adhesion to various surfaces. Motivated by the adhesive microstructures of insects, we examine the behaviour of adhesion and crack propagation in patterned adhesive films. These films are made of silicone

  18. Efficacy of iPad iTunes U Electronic Curriculum in Emergency Medicine Education

    E-Print Network [OSTI]

    Wray, A.; Toohey, S.; Chakravarthy, B.; Wiechmann, W.; Anderson, C.

    2015-01-01

    effect of the learners’ curriculum satisfaction on knowledgeof iPad iTunes U Electronic Curriculum in Emergency Medicinea distance-learning curriculum; it is iPad based and

  19. Measurements of static loading characteristics of a Flexurepivot Tilt Pad Hydrodynamic Bearing 

    E-Print Network [OSTI]

    Walton, Nicholas Van Edward

    1995-01-01

    An experimental investigation examining the static loading characteristics of a four-pad, KMC FLEXUREPIVOT Tilt Pad Hydrodynamic Bearing is presented. Tests are conducted on the TRACE Fluid Film Bearing Element Test Rig for journal speeds ranging...

  20. Measurement of rotordynamic coefficients for a high-speed flexure pivot tilting-pad bearing(load between pad) configuration 

    E-Print Network [OSTI]

    Al-Ghasem, Adnan Mahmoud

    2005-08-29

    . ? ? ? ?? ? ? ? ?? ? ?? ?+ ?? ? ?? ? ? ? ?? ? ?? ?+ ?? ? ?? ? ? ? ?? ? ?? ?= ?? ? ?? ?? y x M M y x C C y x K K f f yy xy yy xy yy xy by bx && && & & In performing a stability analysis of high-speed machinery running on tilting-pad bearings, one would ask if the rotordynamic coefficients should be calculated at the synchronous...

  1. WACR Calibration Report

    SciTech Connect (OSTI)

    Mead, D

    2010-03-23

    Calibration report for the W-Band (95 GHz) ARM Cloud Radar performed for the ARM Climate Research Facility by ProSensing Inc.

  2. Integrating repositories with fuel cycles: The airport authority model

    SciTech Connect (OSTI)

    Forsberg, C. [Massachusetts Inst. of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139-4307 (United States)

    2012-07-01

    The organization of the fuel cycle is a legacy of World War II and the cold war. Fuel cycle facilities were developed and deployed without consideration of the waste management implications. This led to the fuel cycle model of a geological repository site with a single owner, a single function (disposal), and no other facilities on site. Recent studies indicate large economic, safety, repository performance, nonproliferation, and institutional incentives to collocate and integrate all back-end facilities. Site functions could include geological disposal of spent nuclear fuel (SNF) with the option for future retrievability, disposal of other wastes, reprocessing with fuel fabrication, radioisotope production, other facilities that generate significant radioactive wastes, SNF inspection (navy and commercial), and related services such as SNF safeguards equipment testing and training. This implies a site with multiple facilities with different owners sharing some facilities and using common facilities - the repository and SNF receiving. This requires a different repository site institutional structure. We propose development of repository site authorities modeled after airport authorities. Airport authorities manage airports with government-owned runways, collocated or shared public and private airline terminals, commercial and federal military facilities, aircraft maintenance bases, and related operations - all enabled and benefiting the high-value runway asset and access to it via taxi ways. With a repository site authority the high value asset is the repository. The SNF and HLW receiving and storage facilities (equivalent to the airport terminal) serve the repository, any future reprocessing plants, and others with needs for access to SNF and other wastes. Non-public special-built roadways and on-site rail lines (equivalent to taxi ways) connect facilities. Airport authorities are typically chartered by state governments and managed by commissions with members appointed by the state governor, county governments, and city governments. This structure (1) enables state and local governments to work together to maximize job and tax benefits to local communities and the state, (2) provides a mechanism to address local concerns such as airport noise, and (3) creates an institutional structure with large incentives to maximize the value of the common asset, the runway. A repository site authority would have a similar structure and be the local interface to any national waste management authority. (authors)

  3. Calibration method for spectroscopic systems

    DOE Patents [OSTI]

    Sandison, David R. (Edgewood, NM)

    1998-01-01

    Calibration spots of optically-characterized material placed in the field of view of a spectroscopic system allow calibration of the spectroscopic system. Response from the calibration spots is measured and used to calibrate for varying spectroscopic system operating parameters. The accurate calibration achieved allows quantitative spectroscopic analysis of responses taken at different times, different excitation conditions, and of different targets.

  4. Calibration method for spectroscopic systems

    DOE Patents [OSTI]

    Sandison, D.R.

    1998-11-17

    Calibration spots of optically-characterized material placed in the field of view of a spectroscopic system allow calibration of the spectroscopic system. Response from the calibration spots is measured and used to calibrate for varying spectroscopic system operating parameters. The accurate calibration achieved allows quantitative spectroscopic analysis of responses taken at different times, different excitation conditions, and of different targets. 3 figs.

  5. Sandia WIPP calibration traceability

    SciTech Connect (OSTI)

    Schuhen, M.D.; Dean, T.A.

    1996-05-01

    This report summarizes the work performed to establish calibration traceability for the instrumentation used by Sandia National Laboratories at the Waste Isolation Pilot Plant (WIPP) during testing from 1980-1985. Identifying the calibration traceability is an important part of establishing a pedigree for the data and is part of the qualification of existing data. In general, the requirement states that the calibration of Measuring and Test equipment must have a valid relationship to nationally recognized standards or the basis for the calibration must be documented. Sandia recognized that just establishing calibration traceability would not necessarily mean that all QA requirements were met during the certification of test instrumentation. To address this concern, the assessment was expanded to include various activities.

  6. Airport Modern: The Space between International Departures and Arrivals in Modern Korean National Imaginings

    E-Print Network [OSTI]

    Kim, Alice S.

    2013-01-01

    of National(ist) Journeys: Transcontinental Railroads, theAirport Modern: Transcontinental Railways to Transpacificreplaced colonial-era transcontinental railways in the

  7. Toward reducing impact induced brain injury: Lessons from a computational study of army and football helmet pads

    E-Print Network [OSTI]

    Moss, W C; Blackman, E G

    2012-01-01

    We use computational simulations to compare the impact response of different football and U.S. Army helmet pad materials. We conduct experiments to characterize the material response of different helmet pads. We simulate experimental helmet impact tests performed by the U.S. Army to validate our methods. We then simulate a cylindrical impactor striking different pads. The acceleration history of the impactor is used to calculate the Head Injury Criterion for each pad. We conduct sensitivity studies exploring the effects of pad composition, geometry, and material stiffness. We find that: (1) The football pad materials do not outperform the currently used military pad material in militarily-relevant impact scenarios; (2) Optimal material properties for a pad depend on impact energy; and (3) Thicker pads perform better at all velocities. Our analysis suggests that by using larger helmet shells with correspondingly thicker pads, impact-induced traumatic brain injury may be significantly reduced. Keywords: helmet,...

  8. Integrated calibration sphere and calibration step fixture for improved coordinate measurement machine calibration

    DOE Patents [OSTI]

    Clifford, Harry J. (Los Alamos, NM)

    2011-03-22

    A method and apparatus for mounting a calibration sphere to a calibration fixture for Coordinate Measurement Machine (CMM) calibration and qualification is described, decreasing the time required for such qualification, thus allowing the CMM to be used more productively. A number of embodiments are disclosed that allow for new and retrofit manufacture to perform as integrated calibration sphere and calibration fixture devices. This invention renders unnecessary the removal of a calibration sphere prior to CMM measurement of calibration features on calibration fixtures, thereby greatly reducing the time spent qualifying a CMM.

  9. Energy calibration via correlation

    E-Print Network [OSTI]

    Maier, Daniel

    2015-01-01

    The main task of an energy calibration is to find a relation between pulse-height values and the corresponding energies. Doing this for each pulse-height channel individually requires an elaborated input spectrum with an excellent counting statistics and a sophisticated data analysis. This work presents an easy to handle energy calibration process which can operate reliably on calibration measurements with low counting statistics. The method uses a parameter based model for the energy calibration and concludes on the optimal parameters of the model by finding the best correlation between the measured pulse-height spectrum and multiple synthetic pulse-height spectra which are constructed with different sets of calibration parameters. A CdTe-based semiconductor detector and the line emissions of an 241 Am source were used to test the performance of the correlation method in terms of systematic calibration errors for different counting statistics. Up to energies of 60 keV systematic errors were measured to be le...

  10. Review of EU airport energy interests and priorities with respect to ICT, energy efficiency and enhanced building operation 

    E-Print Network [OSTI]

    Costa, A.; Blanes, L. M.; Donnelly, C.; Keane, M. M.

    2012-01-01

    This paper gives an overview on EU airport energy interests and priorities with respect to ICT, energy efficiency and enhanced building operation. To achieve this objective the paper begins with an overview on airports role on energy consumption...

  11. The Integrated Airport: Building a Successful NextGen Testbed

    ScienceCinema (OSTI)

    Frederick-Recascino, Christina [Embry-Riddle Aeronautical University, Daytona Beach, Florida, United States]; Sweigard, Doug [Lockheed Martin Corporation]; Lester, Wade [ERAU

    2010-01-08

    This presentation will describe a unique public-private partnership - the Integrated Airport - that was created to engage in research and testing related to NextGen Technology deployment.  NextGen refers to the program that will be initiated to modernize the US National Airspace.  As with any major, multi-decade initiative, such as NextGen, integration of work efforts by multiple partners in the modernization is critical for success.  This talk will focus on the development of the consortium, how the consortium plans for NextGen initiatives, the series of technology demonstrations we have produced and plans for the future of NextGen testing and implementation. 

  12. Comprehensive Energy Management and CC® at DFW Airport 

    E-Print Network [OSTI]

    Kramer, L.

    2011-01-01

    Rent-A-Car Center 130,000 2004, 2010 Administration Building 81,000 2007 Terminal D 2,000,000 2008-2009 Energy Plaza (CUP) 41,000 tons of capacity 2008-2009 Terminal E 460,000 2010 North Business Center 52,000 2010 Energy Plaza (HVAC) 125,000 2010... International Airport Continuous Commissioning? International Conference for Enhanced Building Operations New York Marriott at the Brooklyn Bridge New York, NY Larry Kramer, P.E., LC, CEM October 20, 2011 Continuous Commissioning? of DFW International...

  13. Alternative Fuels Data Center: Atlanta Airport Converts Shuttles to CNG

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 OutreachProductswsicloudwsiclouddenDVA N C E D B L O O D S TA I NLoans The Oregon DepartmentAtlanta Airport

  14. Alternative Fuels Data Center: Propane Powers Airport Shuttles in New

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 OutreachProductswsicloudwsiclouddenDVA N C E D B L O O D S TA IMarylandOrleans Propane Powers Airport Shuttles

  15. Airport Drive, Missouri: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX ECoop IncIowaWisconsin: Energy ResourcesAir Quality Jump to:Airforce Wind FarmAirport

  16. Mitigating Runoff Contamination Due to DeIcing and Anti-Icing Operations at T.F.Green Airport

    E-Print Network [OSTI]

    Rhode Island, University of

    for the management of the wastewater that is generated. This responsibility is typically outlined in the airport's discharge permit. In Rhode Island, T.F. Green is the primary of six state airports supervised by the Rhode a solution or solutions to RIAC for TF Green Airport by investigating and analyzing different treatments

  17. Determining Pad-Wafer Contact using Dual Emission Laser Induced Fluorescence Caprice Gray1

    E-Print Network [OSTI]

    White, Robert D.

    energy required to break and re-order the chemical bonds on the glass substrate surface so thickness, asperity layer compressibility, surface roughness measurements and polishing pad rebound

  18. HowtoMentorGraduateStudents Professional and Academic Development (PAD) Seminar Series

    E-Print Network [OSTI]

    Finley Jr., Russell L.

    HowtoMentorGraduateStudents Professional and Academic Development (PAD) Seminar Series Friday Vice President for Research Compliance, Division of Research philc@wayne.edu David Rueda, Associate

  19. Table 40. No. 2 Diesel Fuel Prices by Sales Type, PAD District...

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    Information AdministrationPetroleum Marketing Annual 1999 191 Table 40. No. 2 Diesel Fuel Prices by Sales Type, PAD District, and Selected States (Cents per Gallon Excluding...

  20. Table 40. No. 2 Diesel Fuel Prices by Sales Type, PAD District...

    U.S. Energy Information Administration (EIA) Indexed Site

    Information AdministrationPetroleum Marketing Annual 1998 191 Table 40. No. 2 Diesel Fuel Prices by Sales Type, PAD District, and Selected States (Cents per Gallon Excluding...

  1. FCTO Consortia Overview (HyMARC and FC-PAD) Webinar

    Broader source: Energy.gov [DOE]

    Download the presentation slides from the Fuel Cell Technologies Office webinar "FCTO Consortia Overview (HyMARC and FC-PAD)" held on January 7, 2016.

  2. Table A1. Refiner/Reseller Motor Gasoline Prices by Grade, PAD...

    U.S. Energy Information Administration (EIA) Indexed Site

    Petroleum Marketing Annual 1999 401 Table A1. RefinerReseller Motor Gasoline Prices by Grade, PAD District and State, 1984-Present (Cents per Gallon Excluding Taxes) -...

  3. Table 31. Motor Gasoline Prices by Grade, Sales Type, PAD District...

    U.S. Energy Information Administration (EIA) Indexed Site

    Information AdministrationPetroleum Marketing Annual 1999 Table 31. Motor Gasoline Prices by Grade, Sales Type, PAD District, and State (Cents per Gallon Excluding Taxes) -...

  4. Table 31. Motor Gasoline Prices by Grade, Sales Type, PAD District...

    U.S. Energy Information Administration (EIA) Indexed Site

    Information AdministrationPetroleum Marketing Annual 1998 Table 31. Motor Gasoline Prices by Grade, Sales Type, PAD District, and State (Cents per Gallon Excluding Taxes) -...

  5. Table 42. Residual Fuel Oil Prices by PAD District and State

    U.S. Energy Information Administration (EIA) Indexed Site

    Information AdministrationPetroleum Marketing Annual 1999 203 Table 42. Residual Fuel Oil Prices by PAD District and State (Cents per Gallon Excluding Taxes) - Continued...

  6. Table 42. Residual Fuel Oil Prices by PAD District and State

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    Information AdministrationPetroleum Marketing Annual 1998 203 Table 42. Residual Fuel Oil Prices by PAD District and State (Cents per Gallon Excluding Taxes) - Continued...

  7. Los Alamos Shows Airport Security Technology at Work

    ScienceCinema (OSTI)

    Espy, Michelle; Schultz, Larry; Hunter, James

    2014-06-24

    Los Alamos scientists have advanced a Magnetic Resonance Imaging (MRI) technology that may provide a breakthrough for screening liquids at airport security. They've added low-power X-ray data to the mix, and as a result have unlocked a new detection technology. Funded in part by the Department of Homeland Security's Science and Technology Directorate, the new system is named MagRay. The goal is to quickly and accurately distinguish between liquids that visually appear identical. For example, what appears to be a bottle of white wine could potentially be nitromethane, a liquid that could be used to make an explosive. Both are clear liquids, one would be perfectly safe on a commercial aircraft, the other would be strictly prohibited. How to tell them apart quickly without error at an airport security area is the focus of Michelle Espy, Larry Schultz and their team. In this video, Espy and the MagRay team explain how the new technology works, how they've developed an easy operator interface, and what the next steps might be in transitioning this technology to the private sector.

  8. Experimentally Determine the Impact of Jacking-Oil Pockets on the Rotordynamic Characteristics of a Four-Pad, LBP, Tilting-Pad Journal Bearing 

    E-Print Network [OSTI]

    Kluitenberg, Matthew P

    2015-04-29

    Test results that examine the influence of jacking-oil ports on a tilting pad journal (TPJ) bearing are presented. The static and dynamic characteristics before and after adding jacking-oil ports are compared. The test ...

  9. A major cogeneration system goes in at JFK International Airport. Low-visibility privatization in a high-impact environment

    SciTech Connect (OSTI)

    Leibler, J.; Luxton, R.; Ostberg, P.

    1998-04-01

    This article describes the first major privatization effort to be completed at John F. Kennedy International Airport. The airport owner and operator, the Port Authority of New York and New Jersey, decided to seek private sector involvement in a capital-intensive project to expand and upgrade the airport`s heating and air conditioning facilities and construct a new cogeneration plant. Kennedy International Airport Cogeneration (KIAC) Partners, a partnership between Gas Energy Incorporated of New York and Community Energy Alternatives of New Jersey, was selected to develop an energy center to supply electricity and hot and chilled water to meet the airport`s growing energy demand. Construction of a 110 MW cogeneration plant, 7,000 tons of chilled water equipment, and 30,000 feet of hot water delivery piping started immediately. JFK Airport`s critical international position called for this substantial project to be developed almost invisibly; no interruption in heating and air conditioning service and no interference in the airport`s active operations could be tolerated. Commercial operation was achieved in February 1995.

  10. PADS: A Policy Architecture for Distributed Storage Systems Nalini Belaramani, Jiandan Zheng, Amol Nayate, Robert Soule,

    E-Print Network [OSTI]

    Grimm, Robert

    PADS: A Policy Architecture for Distributed Storage Systems Nalini Belaramani, Jiandan Zheng§, Amol for build- ing distributed storage systems. A policy architecture has two aspects. First, a common set for how policies, them- selves, should be specified. In the case of distributed storage systems, PADS

  11. The Bachelor of Public Management program requires the following courses: PAD 3003 Public Management and Administration

    E-Print Network [OSTI]

    Fernandez, Eduardo

    and in the use of quantitative and qualitative research designs. COMMUNICATION (Written Communication; Oral Process and Ethics PAD 4702 Quantitative Inquiry for Public Mangers PAD 4704 Research Methods in Public, and case studies that are grammatically correct and include a thesis statement, body and conclusion

  12. Uncertainty and calibration analysis

    SciTech Connect (OSTI)

    Coutts, D.A.

    1991-03-01

    All measurements contain some deviation from the true value which is being measured. In the common vernacular this deviation between the true value and the measured value is called an inaccuracy, an error, or a mistake. Since all measurements contain errors, it is necessary to accept that there is a limit to how accurate a measurement can be. The undertainty interval combined with the confidence level, is one measure of the accuracy for a measurement or value. Without a statement of uncertainty (or a similar parameter) it is not possible to evaluate if the accuracy of the measurement, or data, is appropriate. The preparation of technical reports, calibration evaluations, and design calculations should consider the accuracy of measurements and data being used. There are many methods to accomplish this. This report provides a consistent method for the handling of measurement tolerances, calibration evaluations and uncertainty calculations. The SRS Quality Assurance (QA) Program requires that the uncertainty of technical data and instrument calibrations be acknowledged and estimated. The QA Program makes some specific technical requirements related to the subject but does not provide a philosophy or method on how uncertainty should be estimated. This report was prepared to provide a technical basis to support the calculation of uncertainties and the calibration of measurement and test equipment for any activity within the Experimental Thermal-Hydraulics (ETH) Group. The methods proposed in this report provide a graded approach for estimating the uncertainty of measurements, data, and calibrations. The method is based on the national consensus standard, ANSI/ASME PTC 19.1.

  13. Long Gamma-Ray Bursts Calibrated by Pade Method and Constraints on Cosmological Models

    E-Print Network [OSTI]

    Jing Liu; Hao Wei

    2014-10-15

    Gamma-ray bursts (GRBs) are among the most powerful sources in the universe. In the recent years, GRBs have been proposed as a complementary probe to type Ia supernovae (SNIa). However, as is well known, there is a circularity problem in the use of GRBs to study cosmology. In this work, based on the Pad\\'e approximant, we propose a new cosmology-independent method to calibrate GRBs. We consider a sample consisting 138 long GRBs and obtain 79 calibrated long GRBs at high redshift $z>1.4$ (named Mayflower sample) which can be used to constrain cosmological models without the circularity problem. Then, we consider the constraints on several cosmological models with these 79 calibrated GRBs and other observational data. We show that GRBs are competent to be a complementary probe to the other well-established cosmological observations.

  14. Internet-Based Calibration of a Multifunction Calibrator

    SciTech Connect (OSTI)

    BUNTING BACA,LISA A.; DUDA JR.,LEONARD E.; WALKER,RUSSELL M.; OLDHAM,NILE; PARKER,MARK

    2000-12-19

    A new way of providing calibration services is evolving which employs the Internet to expand present capabilities and make the calibration process more interactive. Sandia National Laboratories and the National Institute of Standards and Technology are collaborating to set up and demonstrate a remote calibration of multijunction calibrators using this Internet-based technique that is becoming known as e-calibration. This paper describes the measurement philosophy and the Internet resources that can provide real-time audio/video/data exchange, consultation and training, as well as web-accessible test procedures, software and calibration reports. The communication system utilizes commercial hardware and software that should be easy to integrate into most calibration laboratories.

  15. Internet-based calibration of a multifunction calibrator

    SciTech Connect (OSTI)

    BUNTING BACA,LISA A.; DUDA JR.,LEONARD E.; WALKER,RUSSELL M.; OLDHAM,NILE; PARKER,MARK

    2000-04-17

    A new way of providing calibration services is evolving which employs the Internet to expand present capabilities and make the calibration process more interactive. Sandia National Laboratories and the National Institute of Standards and Technology are collaborating to set up and demonstrate a remote calibration of multifunction calibrators using this Internet-based technique that is becoming known as e-calibration. This paper describes the measurement philosophy and the Internet resources that can provide real-time audio/video/data exchange, consultation and training, as well as web-accessible test procedures, software and calibration reports. The communication system utilizes commercial hardware and software that should be easy to integrate into most calibration laboratories.

  16. Calibrated vapor generator source

    DOE Patents [OSTI]

    Davies, J.P.; Larson, R.A.; Goodrich, L.D.; Hall, H.J.; Stoddard, B.D.; Davis, S.G.; Kaser, T.G.; Conrad, F.J.

    1995-09-26

    A portable vapor generator is disclosed that can provide a controlled source of chemical vapors, such as, narcotic or explosive vapors. This source can be used to test and calibrate various types of vapor detection systems by providing a known amount of vapors to the system. The vapor generator is calibrated using a reference ion mobility spectrometer. A method of providing this vapor is described, as follows: explosive or narcotic is deposited on quartz wool, placed in a chamber that can be heated or cooled (depending on the vapor pressure of the material) to control the concentration of vapors in the reservoir. A controlled flow of air is pulsed over the quartz wool releasing a preset quantity of vapors at the outlet. 10 figs.

  17. Calibrated vapor generator source

    DOE Patents [OSTI]

    Davies, John P. (Idaho Falls, ID); Larson, Ronald A. (Idaho Falls, ID); Goodrich, Lorenzo D. (Shelley, ID); Hall, Harold J. (Idaho Falls, ID); Stoddard, Billy D. (Idaho Falls, ID); Davis, Sean G. (Idaho Falls, ID); Kaser, Timothy G. (Idaho Falls, ID); Conrad, Frank J. (Albuquerque, NM)

    1995-01-01

    A portable vapor generator is disclosed that can provide a controlled source of chemical vapors, such as, narcotic or explosive vapors. This source can be used to test and calibrate various types of vapor detection systems by providing a known amount of vapors to the system. The vapor generator is calibrated using a reference ion mobility spectrometer. A method of providing this vapor is described, as follows: explosive or narcotic is deposited on quartz wool, placed in a chamber that can be heated or cooled (depending on the vapor pressure of the material) to control the concentration of vapors in the reservoir. A controlled flow of air is pulsed over the quartz wool releasing a preset quantity of vapors at the outlet.

  18. Mesoscale hybrid calibration artifact

    SciTech Connect (OSTI)

    Tran, Hy D. (Albuquerque, NM); Claudet, Andre A. (Albuquerque, NM); Oliver, Andrew D. (Waltham, MA)

    2010-09-07

    A mesoscale calibration artifact, also called a hybrid artifact, suitable for hybrid dimensional measurement and the method for make the artifact. The hybrid artifact has structural characteristics that make it suitable for dimensional measurement in both vision-based systems and touch-probe-based systems. The hybrid artifact employs the intersection of bulk-micromachined planes to fabricate edges that are sharp to the nanometer level and intersecting planes with crystal-lattice-defined angles.

  19. Estimation of the economic relationship of an airport to the regional economy : a critical analysis

    E-Print Network [OSTI]

    Fortune, Stephen James

    1981-01-01

    In the past decade many major U.S. airports have encountered extensive opposition to plans for future growth and expansion from environmentalists and community groups who cite the noise and air pollution created and the ...

  20. Airport surface traffic optimization and simulation in the presence of uncertainties

    E-Print Network [OSTI]

    Lee, Hanbong

    2014-01-01

    Surface traffic congestion causes significant taxi delays and long queues for takeoffs at busy airports, increasing operational and environmental costs. These impacts may be mitigated by optimizing runway and taxiway ...

  1. Market-Based Alternatives for Managing Congestion at New York's LaGuardia Airport

    E-Print Network [OSTI]

    representatives and other members of the air transportation community. The first simulation placed participants been used at some airports, such as London Heathrow and Paris Charles de Gaulle, since the early 1970s

  2. Estimating current and future benefits of airport surface congestion management techniques

    E-Print Network [OSTI]

    Nakahara, Alex (Alex Hiroo)

    2012-01-01

    Air traffic is expected to continue to grow in the future and improved methods for dealing with the increased demand on the system need to be designed and implemented. One method for reducing surface congestion at airports ...

  3. Energy, Shading and Daylighting Analysis for the Austin Bergstrom International Airport Terminal 

    E-Print Network [OSTI]

    Holder, L. M. III; Holder, L. M. IV

    2002-01-01

    Our firm was under contract with the City of Austin, Texas to perform energy analysis and analysis of the daylighting potential within the New Austin Bergstrom International Airport Terminal. Design of the Passenger Terminal Facility for the New...

  4. Improved Approach to Lidar Airport Obstruction Surveying Using Full-Waveform Data

    E-Print Network [OSTI]

    Nowak, Robert

    . Parrish1 and Robert D. Nowak2 ABSTRACT Over the past decade, the National Oceanic and Atmospheric, or building that penetrates an airport's obstruction identification surfaces (OIS) (FAA 1996; FAA 2008

  5. A Study on the Effects of Unwanted Air Infiltration on Thermal Comfort at an Airport Terminal 

    E-Print Network [OSTI]

    Lander, B.; Wei, G.; Claridge, D.; Caeiro, J.

    2009-01-01

    the comfort levels that people have become accustomed to in public buildings. Airport terminal buildings, such as the one in this study, built before the current energy awareness that is prevalent today have many problems associated with air infiltration...

  6. DOE to Build Hydrogen Fuel Test Facility at West Virginia Airport

    Broader source: Energy.gov [DOE]

    The Office of Fossil Energy's National Energy Technology Laboratory today announced plans to construct and operate a hydrogen fuel production plant and vehicle fueling station at the Yeager Airport in Charleston, W.Va.

  7. Historical Material Analysis of DC745U Pressure Pads

    SciTech Connect (OSTI)

    Ortiz-Acosta, Denisse [Los Alamos National Laboratory

    2012-07-30

    As part of the Enhance Surveillance mission, it is the goal to provide suitable lifetime assessment of stockpile materials. This report is an accumulation of historical publication on the DC745U material and their findings. It is the intention that the B61 LEP program uses this collection of data to further develop their understanding and potential areas of study. DC745U is a commercially available silicone elastomer consisting of dimethyl, methyl-phenyl, and methyl-vinyl siloxane repeat units. Originally, this material was manufactured by Dow Corning as Silastic{reg_sign} DC745U at their manufacturing facility in Kendallville, IN. Recently, Dow Corning shifted this material to the Xiameter{reg_sign} brand product line. Currently, DC745U is available through Xiameter{reg_sign} or Dow Corning's distributor R. D. Abbott Company. DC745U is cured using 0.5 wt% vinyl-specific peroxide curing agent known as Luperox 101 or Varox DBPH-50. This silicone elastomer is used in numerous parts, including two major components (outer pressure pads and aft cap support) in the W80 and as pressure pads on the B61. DC745U is a proprietary formulation, thus Dow Corning provides limited information on its composition and properties. Based on past experience with Dow Corning, DC745U is at risk of formulation changes without notification to the costumer. A formulation change for DC745U may have a significant impact because the network structure is a key variable in determining material properties. The purpose of this report is to provide an overview of historical DC745U studies and identify gaps that need to be addressed in future work. Some of the previous studies include the following: 1. Spectroscopic characterization of raw gum stock. 2. Spectroscopic, thermal, and mechanical studies on cured DC745U. 3. Nuclear Magnetic Resonance (NMR) and solvent swelling studies on DC745U with different crosslink densities. 4. NMR, solvent swelling, thermal, and mechanical studies on thermally aged DC745U. 5. NMR, solvent swelling, thermal, and mechanical studies on radiolytically aged DC745U. Each area is reviewed and further work is suggested to improve our understanding of DC745U for systems engineering, surveillance, aging assessments, and lifetime assessment.

  8. Untappable key distribution system: a one-time-pad booster

    E-Print Network [OSTI]

    Geraldo A. Barbosa; Jeroen van de Graaf

    2015-07-08

    One-time-pad (OTP) encryption simply cannot be cracked, even by a quantum computer. The need of sharing in a secure way supplies of symmetric random keys turned the method almost obsolete as a standing-alone method for fast and large volume telecommunication. Basically, this secure sharing of keys and their renewal, once exhausted, had to be done through couriers, in a slow and costly process. This paper presents a solution for this problem providing a fast and unlimited renewal of secure keys: An untappable key distribution system is presented and detailed. This fast key distribution system utilizes two layers of confidentially protection: 1) Physical noise intrinsic to the optical channel that turn the coded signals into stealth signals and 2) Privacy amplification using a bit pool of refreshed entropy run after run, to eliminate any residual information. The resulting level of security is rigorously calculated and demonstrates that the level of information an eavesdropper could obtain is completely negligible. The random bit sequences, fast and securely distributed, can be used to encrypt text, data or voice.

  9. Micro-scale scratching by soft pad asperities in chemical-mechanical polishing

    E-Print Network [OSTI]

    Kim, Sanha, Ph. D. Massachusetts Institute of Technology

    2013-01-01

    In the manufacture of integrated circuits (IC) and micro-electromechanical systems (MEMS), chemical-mechanical polishing (CMP) is widely used for providing local and global planarization. In the CMP process, polishing pads, ...

  10. NavigatingInterdisciplinaryCareers Professional and Academic Development (PAD) Seminar Series

    E-Print Network [OSTI]

    Finley Jr., Russell L.

    NavigatingInterdisciplinaryCareers Professional and Academic Development (PAD) Seminar Series development and interdisciplinary research Strategies for multiple careers Strategies for tenure and promotion Klein, Faculty Fellow for Interdisciplinary Development, Division of Research and Professor

  11. WhattoDoasaNewFacultyMember Professional and Academic Development (PAD) Seminar Series

    E-Print Network [OSTI]

    Finley Jr., Russell L.

    WhattoDoasaNewFacultyMember Professional and Academic Development (PAD) Seminar Series Friday and your work among research, teaching, and service Seeking advice on teaching, research, setting up a new

  12. The Effect of Pad-asperity Curvature on Material Removal Rate in Chemical-mechanical Polishing

    E-Print Network [OSTI]

    Kim, Sanha

    In chemical-mechanical polishing (CMP), surface asperities of the polishing pad play a key role, for they transmit normal force and impart tangential motion to the hard, nano-scale abrasive particles in the slurry. It has ...

  13. Viscous-poroelastic interaction as mechanism to create adhesion in frogs' toe pads

    E-Print Network [OSTI]

    Tulchinsky, A

    2015-01-01

    The toe pads of frogs consist of soft hexagonal structures and a viscous liquid contained between and within the hexagonal structures. It has been hypothesized that this configuration creates adhesion by allowing for long range capillary forces, or alternatively, by allowing for exit of the liquid and thus improving contact of the toe pad. In this work we suggest interaction between viscosity and elasticity as a mechanism to create temporary adhesion, even in the absence of capillary effects or van der Waals forces. We initially illustrate this concept experimentally by a simplified configuration consisting of two surfaces connected by a liquid bridge and elastic springs. We then utilize poroelastic mixture theory and model frog's toe pads as an elastic porous medium, immersed within a viscous liquid and pressed against a rigid rough surface. The flow between the surface and the toe pad is modeled by the lubrication approximation. Inertia is neglected and analysis of the elastic-viscous dynamics yields a gove...

  14. Lift-off performance in flexure pivot pad and hybrid bearings 

    E-Print Network [OSTI]

    Mertz, David Hunter

    2009-05-15

    Three flexure pivot pad bearings (FPBs) with different preloads are evaluated for use in high performance applications by comparing them to a hybrid hydrostatic bearing (HHB). One application of these bearings is in turbopumps for liquid rocket...

  15. A Novel Computational Model for Tilting Pad Journal Bearings with Soft Pivot Stiffnesses 

    E-Print Network [OSTI]

    Tao, Yujiao 1988-

    2012-12-10

    A novel tilting pad journal bearing model including pivot flexibility as well as temporal fluid inertia effects on the thin film fluid flow aims to accurately predict the bearing forced performance. The predictive model also accounts for the thermal...

  16. Public Funding of Airport Incentives: The Efficacy of the Small Community Air Service Development Grant (SCASDG) Program

    E-Print Network [OSTI]

    Wittman, Michael D.

    2014-01-08

    As U.S. airlines began to restrict available domestic capacity at smaller airports in 2008 as a result of higher

  17. Atmospheric optical calibration system

    DOE Patents [OSTI]

    Hulstrom, Roland L. (Bloomfield, CO); Cannon, Theodore W. (Golden, CO)

    1988-01-01

    An atmospheric optical calibration system is provided to compare actual atmospheric optical conditions to standard atmospheric optical conditions on the basis of aerosol optical depth, relative air mass, and diffuse horizontal skylight to global horizontal photon flux ratio. An indicator can show the extent to which the actual conditions vary from standard conditions. Aerosol scattering and absorption properties, diffuse horizontal skylight to global horizontal photon flux ratio, and precipitable water vapor determined on a real-time basis for optical and pressure measurements are also used to generate a computer spectral model and for correcting actual performance response of a photovoltaic device to standard atmospheric optical condition response on a real-time basis as the device is being tested in actual outdoor conditions.

  18. Atmospheric optical calibration system

    DOE Patents [OSTI]

    Hulstrom, R.L.; Cannon, T.W.

    1988-10-25

    An atmospheric optical calibration system is provided to compare actual atmospheric optical conditions to standard atmospheric optical conditions on the basis of aerosol optical depth, relative air mass, and diffuse horizontal skylight to global horizontal photon flux ratio. An indicator can show the extent to which the actual conditions vary from standard conditions. Aerosol scattering and absorption properties, diffuse horizontal skylight to global horizontal photon flux ratio, and precipitable water vapor determined on a real-time basis for optical and pressure measurements are also used to generate a computer spectral model and for correcting actual performance response of a photovoltaic device to standard atmospheric optical condition response on a real-time basis as the device is being tested in actual outdoor conditions. 7 figs.

  19. ADEPT SCIENTIFIC ENDNOTE LANDESLIZENZ VEREINBARUNG Dies ist eine Vereinbarung zwischen Thomson ResearchSoft mit Hauptsitz in 2141 Palomar Airport Road, Suite 350,

    E-Print Network [OSTI]

    Ott, Albrecht

    ResearchSoft mit Hauptsitz in 2141 Palomar Airport Road, Suite 350, Carlsbad, CA 92009, USA vertreten durch

  20. Paper No. 11.05 1 A Half Century of Tapered-Pile Usage at the John F. Kennedy International Airport

    E-Print Network [OSTI]

    Horvath, John S.

    Paper No. 11.05 1 A Half Century of Tapered-Pile Usage at the John F. Kennedy International Airport. Kennedy International Airport (JFKIA) in New York City began in the late 1940s. Timber piles were used the well-known John F. Kennedy International Airport (JFKIA, originally named New York International

  1. Cost Benefit Analysis Modeling Tool for Electric vs. ICE Airport Ground Support Equipment – Development and Results

    SciTech Connect (OSTI)

    James Francfort; Kevin Morrow; Dimitri Hochard

    2007-02-01

    This report documents efforts to develop a computer tool for modeling the economic payback for comparative airport ground support equipment (GSE) that are propelled by either electric motors or gasoline and diesel engines. The types of GSE modeled are pushback tractors, baggage tractors, and belt loaders. The GSE modeling tool includes an emissions module that estimates the amount of tailpipe emissions saved by replacing internal combustion engine GSE with electric GSE. This report contains modeling assumptions, methodology, a user’s manual, and modeling results. The model was developed based on the operations of two airlines at four United States airports.

  2. Increased Efficiency with Model Based Calibration | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Calibration Increased Efficiency with Model Based Calibration Meeting future TIER 4 emission limits requires the integration of many new technology elements. deer09diewald.pdf...

  3. Thermal emission measurement and calibration

    E-Print Network [OSTI]

    Brown, Susannah (Susannah R.)

    2009-01-01

    This thesis details a measurement setup and experimental procedures for emittance measurements using a Fourier transform infrared spectrometer. We calibrate the FTIR measurement system using measurements of a blackbody ...

  4. STRATEGIC PLANNING FOR AIRPORT CAPACITY: An Appreciation of Australia's Process for Sydney1

    E-Print Network [OSTI]

    1 STRATEGIC PLANNING FOR AIRPORT CAPACITY: An Appreciation of Australia's Process for Sydney1 demonstrating by example the advantages of strategic planning as compared to traditional master planning. Strategic planning recognises that there is massive uncertainty in long-term forecasts, and consequently

  5. A Portable Low-Cost High Density Sensor Network for Air Quality at London Heathrow Airport

    E-Print Network [OSTI]

    Jackson, Sophie

    species: CO, NO, O3, SO2, NO2 (electrochemical (EC) at 2 s) CO2 and total VOCs (optical at 10 s). · Size stations outside LHR (all CO2, sizeA Portable Low-Cost High Density Sensor Network for Air Quality at London Heathrow Airport Olalekan

  6. Problem Statement: Airports need to achieve carbon neutral growth operating an enterprise

    E-Print Network [OSTI]

    for Rental Cars and Commercial Vehicles Convert Rental Cars from Gas to Hybrid 50% Rental Fleet to Hybrid 0. Alternatively Fueled Airport Access Taxis (e.g. Hybrids or Electric vehicles) Inhibiting Factors to Carbon annually) 0.63 17,400 Alternatively Fueled Taxis Convert Taxi Fleet to Hybrid [Control through MWAA

  7. Implementation of alternative bio-based fuels in aviation: The Clean Airports Program

    SciTech Connect (OSTI)

    Shauck, M.E.; Zanin, M.G.

    1997-12-31

    The Renewable Aviation Fuels Development Center at Baylor University in Waco, Texas, was designated, in March 1996, by the US Department of Energy (US DOE) as the national coordinator of the Clean Airports Program. This program, a spin-off of the Clean Cities Program, was initiated to increase the use of alternative fuels in aviation. There are two major fuels used in aviation today, the current piston engine aviation gasoline, and the current turbine engine fuel. The environmental impact of each of these fuels is significant. Aviation Gasoline (100LL), currently used in the General Aviation piston engine fleet, contributes 100% of the emissions containing lead in the USA today. In the case of the turbine engine fuel (Jet fuel), there are two major environmental impacts to be considered: the local, in the vicinity of the airports, and the global impact on climate change. The Clean Airports Program was established to promote the use of clean burning fuels in order to achieve and maintain clean air at and in the vicinities of airports through the use of alternative fuel-powered air and ground transportation vehicles.

  8. PREDICTION OF FOG EPISODES AT THE AIRPORT OF MADRID-BARAJAS USING DIFFERENT MODELING APPROACHES

    E-Print Network [OSTI]

    Politècnica de Catalunya, Universitat

    PREDICTION OF FOG EPISODES AT THE AIRPORT OF MADRID-BARAJAS USING DIFFERENT MODELING APPROACHES Meteorología (INM) has been investigating for some time the phenomena related to the formation of fog episodes between the development of fog and the establishment of katabatic flows in the region, generally under

  9. HumanWildlife Conflicts 2(2):240247, Fall 2008 Mammalian hazards at small airports in

    E-Print Network [OSTI]

    fence maintenance is vital for effective wildlife- strike management at small airports. Key words,000 hours of aircraft downtime each year and cost the civil aviation industry >$556 million annually (Cleary the inception of aviation 100 years ago (Sodhi 2002). Unfortunately, the probability of wildlife strikes

  10. Detection Probability Modeling for Airport Wind-Shear August 28, 2008

    E-Print Network [OSTI]

    Cho, John Y. N.

    Detection Probability Modeling for Airport Wind-Shear Sensors August 28, 2008 John Y. N. Cho Robert An objective wind-shear detection probability estimation model is developed for radar, lidar, and sensor combinations. The model includes effects of system sensitivity, site-specific wind-shear, clutter, and terrain

  11. Directions to the University of Connecticut Storrs Campus From Bradley International Airport

    E-Print Network [OSTI]

    Olshevsky, Vadim

    Directions to the University of Connecticut ­ Storrs Campus From Bradley International Airport on Connecticut Route 195 about 6 miles to the University. (You will come to the intersection of Rt. 195 and Rt of the exit ramp. Travel south on Connecticut Route 195 about 6 miles to the University. (You will come

  12. A Phase I Cultural Resources Survey of the Easterwood Airport Project in Central Brazos County, Texas 

    E-Print Network [OSTI]

    Moore, William

    2015-06-30

    An archaeological survey of 4.2 acre tract at Easterwood Airport in the city limits of College Station, Texas (central Brazos County) was conducted on May 10, 2002 by Brazos Valley Research Associates of Bryan, Texas. The Texas A&M University...

  13. Dynamic and Static Characteristics of a Rocker-Pivot, Tilting-Pad Bearing with 50% and 60% Offsets. 

    E-Print Network [OSTI]

    Kulhanek, Chris David

    2012-02-14

    the following characteristics: 5-pads, 101.6 mm (4.0 in) nominal diameter, .0814 - .0837 mm (.0032 - .0033 in) radial bearing clearance, .25 to .27 preload, 60.325 mm (2.375 in) axial pad length. Operating conditions included loads from 0 to 3101 kPa (450 psi...

  14. WorkingwithIndustry:WhyCollaborationsareImportant Professional and Academic Development (PAD) Seminar Series

    E-Print Network [OSTI]

    Finley Jr., Russell L.

    WorkingwithIndustry:WhyCollaborationsareImportant Professional and Academic Development (PAD) Seminar Series Tuesday, April 5, 2011 ­ 9:00 a.m. to 10:30 a.m. SOM Margherio Conference Center Discussion Topics: Collaborative research with industry and the implications for both sides What academic labs need

  15. 28 June, 2005 PADS 2005 1 Service Provisioning for HLA-based

    E-Print Network [OSTI]

    Teo, Yong-Meng

    Run-Time Infrastructure (RTI) Federation Management Declaration Management Object Management Ownership Level Architecture #12;28-Jun-05 3 28 June, 2005 PADS 2005 5 HLA/RTI: Communications Federate Code of Services Distributed Simulation over the Wide-Area- Network using IEEE HLA/RTI requires: Hardware

  16. Sun Ultra 80 SPEC CFP95 Sun Forte Inter-Array Padding for Data Localization

    E-Print Network [OSTI]

    Kasahara, Hironori

    Sun Ultra 80 SPEC CFP95 Sun Forte 5.5 Inter-Array Padding for Data Localization with Static for data localization to minimize cache conflict misses. In the evaluation on Sun Ultra 80 using SPEC CFP95, the OSCAR multigrain compiler gave us up to 5.5 times speedup against Sun Forte automatic paralleling

  17. Efficacy of iPad iTunes U Electronic Curriculum in Emergency Medicine Education

    E-Print Network [OSTI]

    Wray, A.; Toohey, S.; Chakravarthy, B.; Wiechmann, W.; Anderson, C.

    2015-01-01

    monthly modules would have increased In-Training Exam scoresmodules per month. Objectives: The primary outcome was improvement of In-TrainingTraining Exam Scores of those who consistently complete the iPad curriculum (defined by completion of >75% of modules)

  18. Self-calibrating multiplexer circuit

    DOE Patents [OSTI]

    Wahl, Chris P. (North Huntingdon, PA)

    1997-01-01

    A time domain multiplexer system with automatic determination of acceptable multiplexer output limits, error determination, or correction is comprised of a time domain multiplexer, a computer, a constant current source capable of at least three distinct current levels, and two series resistances employed for calibration and testing. A two point linear calibration curve defining acceptable multiplexer voltage limits may be defined by the computer by determining the voltage output of the multiplexer to very accurately known input signals developed from predetermined current levels across the series resistances. Drift in the multiplexer may be detected by the computer when the output voltage limits, expected during normal operation, are exceeded, or the relationship defined by the calibration curve is invalidated.

  19. Why some airport-rail links get built and others do not : the role of institutions, equity and financing

    E-Print Network [OSTI]

    Nickel, Julia, S.M. Massachusetts Institute of Technology

    2011-01-01

    The thesis seeks to provide an understanding of reasons for different outcomes of airport ground access projects. Five in-depth case studies (Hongkong, Tokyo-Narita, London- Heathrow, Chicago- O'Hare and Paris-Charles de ...

  20. A comparison of aircraft trajectory-based and aggregate queue-based control of airport taxi processes

    E-Print Network [OSTI]

    Lee, Hanbong

    There is significant potential to decrease fuel burn, emissions, and delays of aircraft at airports by optimizing surface operations. A simple surface traffic optimization approach is to hold aircraft back at the gates ...

  1. Using a Constant Volume Displacement Ventilation System to Create a Micro Climate in a Large Airport Terminal in Bangkok 

    E-Print Network [OSTI]

    Simmonds, P.; Gaw, W.

    1996-01-01

    In order to conserve energy and create a comfortable climate for both passengers and workers at a new large international airport in Thailand, a design concept was created where only the first 2m above the occupied zone is conditioned...

  2. Measurements Versus Predictions for the Static and Dynamic Characteristics of a Four-pad Rocker-pivot, Tilting-pad Journal Bearing 

    E-Print Network [OSTI]

    Tschoepe, David 1987-

    2012-08-16

    here, both codes do a decent job at predicting impedance coefficients. iv DEDICATION For my family, You don?t choose your family. They are God?s gift to you, as you are to them. ~Desmond Tutu v ACKNOWLEDGEMENTS First I... in the ?i? direction) [L/t2] Cij Direct and cross-coupled damping coefficients [F.t/L] ?Cij Uncertainty of direct and cross-coupled damping coefficients [F.t/L] Cb Radial bearing clearance [L] Cp Radial pad clearance [L] cp Lubricant specific heat...

  3. Estimating Traveler Populations at Airport and Cruise Terminals for Population Distribution and Dynamics

    SciTech Connect (OSTI)

    Jochem, Warren C; Sims, Kelly M; Bright, Eddie A; Urban, Marie L; Rose, Amy N; Coleman, Phil R; Bhaduri, Budhendra L

    2013-01-01

    In recent years, uses of high-resolution population distribution databases are increasing steadily for environmental, socioeconomic, public health, and disaster-related research and operations. With the development of daytime population distribution, temporal resolution of such databases has been improved. However, the lack of incorporation of transitional population, namely business and leisure travelers, leaves a significant population unaccounted for within the critical infrastructure networks, such as at transportation hubs. This paper presents two general methodologies for estimating passenger populations in airport and cruise port terminals at a high temporal resolution which can be incorporated into existing population distribution models. The methodologies are geographically scalable and are based on, and demonstrate how, two different transportation hubs with disparate temporal population dynamics can be modeled utilizing publicly available databases including novel data sources of flight activity from the Internet which are updated in near-real time. The airport population estimation model shows great potential for rapid implementation for a large collection of airports on a national scale, and the results suggest reasonable accuracy in the estimated passenger traffic. By incorporating population dynamics at high temporal resolutions into population distribution models, we hope to improve the estimates of populations exposed to or at risk to disasters, thereby improving emergency planning and response, and leading to more informed policy decisions.

  4. PAD, a computer-aided molecular model building system utilizing two-dimensional graphical input 

    E-Print Network [OSTI]

    White, William Gerald

    1980-01-01

    and an artist. CONTENTS CHAPTER I. BACKGROUND: INTERFACING COMPUTER AND CHEMIcT Graphical Input Hardware Evolution. . . . . Software Systems: Using the Hardware, , Chemical Applications. Program PAD xn Perspective. CHAPTER II. YATERIA' S AND METHODS... are used. The 2-D coordinates of each atom input by the user are stored permanently in XS and YS, after temporary storage in IX and IY. Arrays XS and YS are each 99 elements long, as are all other arrays storing information about input atoms; therefore...

  5. Universal Padding Schemes for RSA Jean-S ebastien Coron, Marc Joye, David Naccache, and Pascal Paillier

    E-Print Network [OSTI]

    International Association for Cryptologic Research (IACR)

    Universal Padding Schemes for RSA Jean-S#19;ebastien Coron, Marc Joye, David Naccache, and Pascal-sebastien.coron, marc.joye, david.naccache, pascal.paillierg@gemplus.com Abstract. A common practice to encrypt with RSA

  6. EFFECTS OF AN iPAD iBOOK ON READING COMPREHENSION, ELECTRODERMAL ACTIVITY, AND ENGAGEMENT FOR ADOLESCENTS WITH DISABILITIES

    E-Print Network [OSTI]

    Pollitt, Daniel Thomas

    2013-12-31

    textbooks. Leveraging media and interactive widgets, iBooks Author holds promise for delivering content to learners of all needs. However, little empirical research currently supports the iPad as a textbook. In this intervention study, 22 middle school...

  7. Spinning angle optical calibration apparatus

    DOE Patents [OSTI]

    Beer, Stephen K. (Morgantown, WV); Pratt, II, Harold R. (Morgantown, WV)

    1991-01-01

    An optical calibration apparatus is provided for calibrating and reproducing spinning angles in cross-polarization, nuclear magnetic resonance spectroscopy. An illuminated magnifying apparatus enables optical setting an accurate reproducing of spinning "magic angles" in cross-polarization, nuclear magnetic resonance spectroscopy experiments. A reference mark scribed on an edge of a spinning angle test sample holder is illuminated by a light source and viewed through a magnifying scope. When the "magic angle" of a sample material used as a standard is attained by varying the angular position of the sample holder, the coordinate position of the reference mark relative to a graduation or graduations on a reticle in the magnifying scope is noted. Thereafter, the spinning "magic angle" of a test material having similar nuclear properties to the standard is attained by returning the sample holder back to the originally noted coordinate position.

  8. Calibration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 OutreachProductswsicloudwsiclouddenDVA N C E D B LReports from the CloudGEGR-N Goods POCTBT Y-1259techniques for a

  9. Calibration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 OutreachProductswsicloudwsiclouddenDVA N C E D B LReports from the CloudGEGR-N Goods POCTBT Y-1259techniques for

  10. EA-2000: Proposed Land Transfer to Develop a General Aviation Airport at the East Tennessee Technology Park Heritage Center, Oak Ridge, Tennessee

    Broader source: Energy.gov [DOE]

    DOE is preparing an EA to assess potential environmental impacts of the proposed land transfer to the Metropolitan Knoxville Airport Authority for the development of a general aviation airport at the East Tennessee Technology Park Heritage Center, in Oak Ridge, Tennessee.

  11. Calibration of the IMB Detector

    SciTech Connect (OSTI)

    Becker-Szendy, R.; Bionta, R.M.; Bratton, C.B.; Casper, D.; Claus, R.; Cortez, B.; Dye, S.T.; Errede, S.; Foster, G.W.; Gajewski, W.; Ganezer, K.; Goldhaber, M.; Haines, T.J.; Halverson, P.G.; Hazen, E.; Jones, T.W.; Kielczewska, D.; Kropp, W.R.; Learned, J.G.; Losecco, J.M.; Matsuno, S.; /UC, Irvine /Michigan U. /Brookhaven /Boston U. /Hawaii U. /University Coll. London /Warsaw U. /Cleveland State U. /Notre Dame U. /Louisiana State U. /Maryland U. /AT-T Bell Labs, Holmdel /Illinois U., Urbana /Fermilab /LLNL, Livermore /New Mexico U. /SLAC /Adelaide U. /CERN /Cal State, Dominguez Hills

    2012-04-03

    The IMB detector (named after its founding institutions: University of California, Irvine, the University of Michigan and Brookhaven National Laboratory) collected data on a wide range of phenomena for over eight years. It was the first and the largest of the ring imaging water Cherenkov detectors. The detector consisted of 8000 metric tons of ultra-pure water instrumented with 2048 photomultiplier tubes (PMTs). The PMTs were placed on the roof, floor, and walls of the detector in a lattice of approximately 1 m spacing. It made measurements of contained events that ranged in energy from 15 MeV up to 1.5 GeV. This paper describes the calibration of the IMB detector. This procedure was accurate and stable over a wide range of physical variables. It was used with little change throughout the entire eight-year lifetime of the experiment. The IMB calibration is a model for future large-scale detectors that employ the water Cherenkov technique.

  12. iPad Price Guide -2015 Wi-Fi Only Wi-Fi/Cellular

    E-Print Network [OSTI]

    Burton, Geoffrey R.

    iPad Price Guide - 2015 Wi-Fi Only Wi-Fi/Cellular 16GB 64GB 128GB Wi-Fi Only Wi-Fi/Cellular 16GB 64, 5MP iSight Camera Available in Space Grey or Silver Capacity Wi-Fi Only £250 ex VAT £281 ex VAT Wi-Fi/Cellular in Space Grey or Silver Capacity Wi-Fi Only £187 ex VAT £219 ex VAT Wi-Fi/Cellular £266 ex VAT £297 ex VAT

  13. Table A1. Refiner/Reseller Motor Gasoline Prices by Grade, PAD District

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: AlternativeMonthly","10/2015"Monthly","10/2015" ,"Release7CubicthroughtheSeptember 24,4,630.22 Consumption Ratios PAD District

  14. Table A1. Refiner/Reseller Motor Gasoline Prices by Grade, PAD District

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: AlternativeMonthly","10/2015"Monthly","10/2015" ,"Release7CubicthroughtheSeptember 24,4,630.22 Consumption Ratios PAD District

  15. Table A1. Refiner/Reseller Motor Gasoline Prices by Grade, PAD District

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: AlternativeMonthly","10/2015"Monthly","10/2015" ,"Release7CubicthroughtheSeptember 24,4,630.22 Consumption Ratios PAD District

  16. Optical Calibration For Jefferson Lab HKS Spectrometer

    E-Print Network [OSTI]

    L. Yuan; L. Tang

    2005-11-04

    In order to accept very forward angle scattering particles, Jefferson Lab HKS experiment uses an on-target zero degree dipole magnet. The usual spectrometer optics calibration procedure has to be modified due to this on-target field. This paper describes a new method to calibrate HKS spectrometer system. The simulation of the calibration procedure shows the required resolution can be achieved from initially inaccurate optical description.

  17. Calibration by Optimization Without Using Derivatives

    E-Print Network [OSTI]

    2015-03-05

    Mar 5, 2015 ... The Bureau International des Poids et Mesures defines: The .... the functional relations specified by the calibrating function ˜fcal are preserved.

  18. Field Calibration Facilities for Environmental Measurement of...

    Office of Environmental Management (EM)

    October 2013) Field Calibration Facilities for Environmental Measurement of Radium, Thorium, and Potassium (October 2013) The first edition of this report, released in October...

  19. Calibration Guide Agilent Technologies ESA Spectrum Analyzers

    E-Print Network [OSTI]

    Anlage, Steven

    Calibration Guide Agilent Technologies ESA Spectrum Analyzers This manual provides documentation periodically. For the latest information about Agilent ESA Spectrum Analyzers, including firmware upgrades

  20. Bayesian Calibration in Dakota | ornl.gov

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    models, and particular implementations in Dakota. The talk will also present current research directions the Dakota team is pursuing for Bayesian calibration methods, including...

  1. Next Generation Calibration Models with Dimensional Modeling...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Decision Tree Based Control Model-Based Transient Calibration Optimization for Next Generation Diesel Engines An Accelerated Aging Method for Diesel Exhaust Aftertreatment Systems...

  2. Calibrations, Monopoles and Fuzzy Funnels

    E-Print Network [OSTI]

    Neil R. Constable; Neil D. Lambert

    2002-07-09

    We present new non-Abelian solitonic configurations in the low energy effective theory describing a collection of N parallel D1--branes. These configurations preserve 1/4, 1/8, 1/16 and 1/32 of the spacetime supersymmetry. They are solutions to a set of generalised Nahm's equations which are related to self-duality equations in eight dimensions. Our solutions represent D1--branes which expand into fuzzy funnel configurations ending on collections of intersecting D3--branes. Supersymmetry dictates that such intersecting D3--branes must lie on a calibrated three-surface of spacetime and we argue that the generalised Nahm's equations encode the data for the construction of magnetic monopoles on the relevant three-surfaces.

  3. Polarized Light Cues Underlie Compass Calibration in

    E-Print Network [OSTI]

    Phillips, John B.

    .e., geographic) directional system that provides the primary calibration reference for all of the compasses with respect to a common reference (13). Here, we show that the primary calibration reference is derived from of migration (6, 7, 14­16) but that the reverse is true once birds begin migration; that is, the magnetic

  4. Smooth Calibration, Leaky Forecasts, and Finite Recall

    E-Print Network [OSTI]

    Hart, Sergiu

    Smooth Calibration, Leaky Forecasts, and Finite Recall Sergiu Hart October 2015 SERGIU HART c 2015 ­ p. #12;Smooth Calibration, Leaky Forecasts, and Finite Recall Sergiu Hart Center for the Study of Rationality Dept of Mathematics Dept of Economics The Hebrew University of Jerusalem hart@huji.ac.il http://www.ma.huji.ac.il/hart

  5. ROBOT CALIBRATION USING LEAST-SQUARES AND

    E-Print Network [OSTI]

    Flanagan, Randy

    ROBOT CALIBRATION USING LEAST-SQUARES AND P OLAR-DEC OMP O SITION FILTERING Gregory Ioannldes 1-axis robotic manipulators. The method proposed by the authors is based on a least-square estimation of the Yaskawa Motoman Robot was calibrated. The measurements of the Cartesian coordinates of points were

  6. The Palomar Testbed Interferometer Calibrator Catalog

    E-Print Network [OSTI]

    G. T. van Belle; G. van Belle; M. J. Creech-Eakman; J. Coyne; A. F. Boden; R. L. Akeson; D. R. Ciardi; K. M. Rykoski; R. R. Thompson; B. F. Lane; for The PTI Collaboration

    2007-11-27

    The Palomar Testbed Interferometer (PTI) archive of observations between 1998 and 2005 is examined for objects appropriate for calibration of optical long-baseline interferometer observations - stars that are predictably point-like and single. Approximately 1,400 nights of data on 1,800 objects were examined for this investigation. We compare those observations to an intensively studied object that is a suitable calibrator, HD217014, and statistically compare each candidate calibrator to that object by computing both a Mahalanobis distance and a Principal Component Analysis. Our hypothesis is that the frequency distribution of visibility data associated with calibrator stars differs from non-calibrator stars such as binary stars. Spectroscopic binaries resolved by PTI, objects known to be unsuitable for calibrator use, are similarly tested to establish detection limits of this approach. From this investigation, we find more than 350 observed stars suitable for use as calibrators (with an additional $\\approx 140$ being rejected), corresponding to $\\gtrsim 95%$ sky coverage for PTI. This approach is noteworthy in that it rigorously establishes calibration sources through a traceable, empirical methodology, leveraging the predictions of spectral energy distribution modeling but also verifying it with the rich body of PTI's on-sky observations.

  7. A derivative standard for polarimeter calibration

    SciTech Connect (OSTI)

    Mulhollan, G.; Clendenin, J.; Saez, P. [and others

    1996-10-01

    A long-standing problem in polarized electron physics is the lack of a traceable standard for calibrating electron spin polarimeters. While several polarimeters are absolutely calibrated to better than 2%, the typical instrument has an inherent accuracy no better than 10%. This variability among polarimeters makes it difficult to compare advances in polarized electron sources between laboratories. The authors have undertaken an effort to establish 100 nm thick molecular beam epitaxy grown GaAs(110) as a material which may be used as a derivative standard for calibrating systems possessing a solid state polarized electron source. The near-bandgap spin polarization of photoelectrons emitted from this material has been characterized for a variety of conditions and several laboratories which possess well calibrated polarimeters have measured the photoelectron polarization of cathodes cut from a common wafer. Despite instrumentation differences, the spread in the measurements is sufficiently small that this material may be used as a derivative calibration standard.

  8. DFW Airport 

    E-Print Network [OSTI]

    Dennis, J. R.

    2011-01-01

    ? Rents ~2 million cars per year ? Total electric ? 7.7 million kWh annually 10 Continuous Commissioning? - Consolidated Rent-A-Car Center CC? Assessment/Implementation ? Excessive outside air ? Duct static pressure too high ? Economizer cycle... at t H o u rs (K W H ) RAC Electric Consumption Over $767,000 in Total Savings 18% reduction in annual average kWh 11 Continuous Commissioning? - Consolidated Rent-A-Car Center Results of CC Project 12 Continuous Commissioning...

  9. Closure Report for Corrective Action Unit 224: Decon Pad and Septic Systems, Nevada Test Site, Nevada

    SciTech Connect (OSTI)

    NSTec Environmental Restoration

    2007-10-01

    Corrective Action Unit (CAU) 224 is located in Areas 02, 03, 05, 06, 11, and 23 of the Nevada Test Site, which is situated approximately 65 miles northwest of Las Vegas, Nevada. CAU 224 is listed in the Federal Facility Agreement and Consent Order (FFACO) of 1996 as Decon Pad and Septic Systems and is comprised of the following nine Corrective Action Sites (CASs): CAS 02-04-01, Septic Tank (Buried); CAS 03-05-01, Leachfield; CAS 05-04-01, Septic Tanks (4)/Discharge Area; CAS 06-03-01, Sewage Lagoons (3); CAS 06-05-01, Leachfield; CAS 06-17-04, Decon Pad and Wastewater Catch; CAS 06-23-01, Decon Pad Discharge Piping; CAS 11-04-01, Sewage Lagoon; and CAS 23-05-02, Leachfield. The Nevada Division of Environmental Protection (NDEP)-approved corrective action alternative for CASs 02-04-01, 03-05-01, 06-03-01, 11-04-01, and 23-05-02 is no further action. As a best management practice, the septic tanks and distribution box were removed from CASs 02-04-01 and 11-04-01 and disposed of as hydrocarbon waste. The NDEP-approved correction action alternative for CASs 05-04-01, 06-05-01, 06-17-04, and 06-23-01 is clean closure. Closure activities for these CASs included removing and disposing of radiologically and pesticide-impacted soil and debris. CAU 224 was closed in accordance with the NDEP-approved CAU 224 Corrective Action Plan (CAP). The closure activities specified in the CAP were based on the recommendations presented in the CAU 224 Corrective Action Decision Document (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2005). This Closure Report documents CAU 224 closure activities. During closure activities, approximately 60 cubic yards (yd3) of mixed waste in the form of soil and debris; approximately 70 yd{sup 3} of sanitary waste in the form of soil, liquid from septic tanks, and concrete debris; approximately 10 yd{sup 3} of hazardous waste in the form of pesticide-impacted soil; approximately 0.5 yd{sup 3} of universal waste in the form of fluorescent light bulbs; and approximately 0.5 yd{sup 3} of low-level waste in the form of a radiologically impacted fire hose rack were generated, managed, and disposed of appropriately. Waste minimization techniques, such as the utilization of laboratory analysis and field screening to guide the extent of excavations, were employed during the performance of closure work.

  10. USENIX Association NSDI '09: 6th USENIX Symposium on Networked Systems Design and Implementation 59 PADS: A Policy Architecture for Distributed Storage Systems

    E-Print Network [OSTI]

    Dahlin, Michael D.

    PADS: A Policy Architecture for Distributed Storage Systems Nalini Belaramani, Jiandan Zheng§, Amol for build- ing distributed storage systems. A policy architecture has two aspects. First, a common set for how policies, them- selves, should be specified. In the case of distributed storage systems, PADS

  11. Calibrating page sized Gafchromic EBT3 films

    SciTech Connect (OSTI)

    Crijns, W.; Maes, F.; Heide, U. A. van der; Van den Heuvel, F. [Department of Radiation Oncology, University Hospitals Leuven, Herestraat 49, 3000 Leuven (Belgium); Department ESAT/PSI-Medical Image Computing, Medical Imaging Research Center, KU Leuven, Herestraat 49, 3000 Leuven (Belgium); Department of Radiation Oncology, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Radiation Oncology, University Hospitals Leuven, Herestraat 49, 3000 Leuven (Belgium)

    2013-01-15

    Purpose: The purpose is the development of a novel calibration method for dosimetry with Gafchromic EBT3 films. The method should be applicable for pretreatment verification of volumetric modulated arc, and intensity modulated radiotherapy. Because the exposed area on film can be large for such treatments, lateral scan errors must be taken into account. The correction for the lateral scan effect is obtained from the calibration data itself. Methods: In this work, the film measurements were modeled using their relative scan values (Transmittance, T). Inside the transmittance domain a linear combination and a parabolic lateral scan correction described the observed transmittance values. The linear combination model, combined a monomer transmittance state (T{sub 0}) and a polymer transmittance state (T{sub {infinity}}) of the film. The dose domain was associated with the observed effects in the transmittance domain through a rational calibration function. On the calibration film only simple static fields were applied and page sized films were used for calibration and measurements (treatment verification). Four different calibration setups were considered and compared with respect to dose estimation accuracy. The first (I) used a calibration table from 32 regions of interest (ROIs) spread on 4 calibration films, the second (II) used 16 ROIs spread on 2 calibration films, the third (III), and fourth (IV) used 8 ROIs spread on a single calibration film. The calibration tables of the setups I, II, and IV contained eight dose levels delivered to different positions on the films, while for setup III only four dose levels were applied. Validation was performed by irradiating film strips with known doses at two different time points over the course of a week. Accuracy of the dose response and the lateral effect correction was estimated using the dose difference and the root mean squared error (RMSE), respectively. Results: A calibration based on two films was the optimal balance between cost effectiveness and dosimetric accuracy. The validation resulted in dose errors of 1%-2% for the two different time points, with a maximal absolute dose error around 0.05 Gy. The lateral correction reduced the RMSE values on the sides of the film to the RMSE values at the center of the film. Conclusions: EBT3 Gafchromic films were calibrated for large field dosimetry with a limited number of page sized films and simple static calibration fields. The transmittance was modeled as a linear combination of two transmittance states, and associated with dose using a rational calibration function. Additionally, the lateral scan effect was resolved in the calibration function itself. This allows the use of page sized films. Only two calibration films were required to estimate both the dose and the lateral response. The calibration films were used over the course of a week, with residual dose errors Less-Than-Or-Slanted-Equal-To 2% or Less-Than-Or-Slanted-Equal-To 0.05 Gy.

  12. Jet energy calibration at the LHC

    E-Print Network [OSTI]

    Ariel Schwartzman

    2015-09-17

    Jets are one of the most prominent physics signatures of high energy proton proton (p-p) collisions at the Large Hadron Collider (LHC). They are key physics objects for precision measurements and searches for new phenomena. This review provides an overview of the reconstruction and calibration of jets at the LHC during its first Run. ATLAS and CMS developed different approaches for the reconstruction of jets, but use similar methods for the energy calibration. ATLAS reconstructs jets utilizing input signals from their calorimeters and use charged particle tracks to refine their energy measurement and suppress the effects of multiple p-p interactions (pileup). CMS, instead, combines calorimeter and tracking information to build jets from particle flow objects. Jets are calibrated using Monte Carlo (MC) simulations and a residual in situ calibration derived from collision data is applied to correct for the differences in jet response between data and Monte Carlo. Large samples of dijet, Z+jets, and photon+jet events at the LHC allowed the calibration of jets with high precision, leading to very small systematic uncertainties. Both ATLAS and CMS achieved a jet energy calibration uncertainty of about 1% in the central detector region and for jets with transverse momentum pT>100 GeV. At low jet pT, the jet energy calibration uncertainty is less than 4%, with dominant contributions from pileup, differences in energy scale between quark and gluon jets, and jet flavor composition.

  13. Heat transfer in ice hockey halls: measurements, energy analysis and analytical ice pad temperature profile

    E-Print Network [OSTI]

    Ferrantelli, Andrea

    2015-01-01

    We consider heat transfer processes in an ice hockey hall, during operating conditions, with a bottom-up approach based upon on-site measurements. Detailed temperature data of both the ice pad and the air above the ice rink are used for a heat balance calculation in the steady-state regime, which quantifies the impact of each single heat source. We solve the heat equation in the ice slab in transient regime, and obtain a general analytical formula for the temperature profile. This solution is then applied to the resurfacing process by using our measurements as (time-dependent) boundary conditions (b.c.), and compared to an analogous numerical computation with good agreement. Our analytical formula is given with implicit initial condition and b.c., therefore it can be used not only in ice halls, but in a large variety of engineering applications.

  14. Heat transfer in ice hockey halls: measurements, energy analysis and analytical ice pad temperature profile

    E-Print Network [OSTI]

    Andrea Ferrantelli; Klaus Viljanen

    2015-06-30

    We consider heat transfer processes in an ice hockey hall, during operating conditions, with a bottom-up approach based upon on-site measurements. Detailed temperature data of both the ice pad and the air above the ice rink are used for a heat balance calculation in the steady-state regime, which quantifies the impact of each single heat source. We solve the heat equation in the ice slab in transient regime, and obtain a general analytical formula for the temperature profile. This solution is then applied to the resurfacing process by using our measurements as (time-dependent) boundary conditions (b.c.), and compared to an analogous numerical computation with good agreement. Our analytical formula is given with implicit initial condition and b.c., therefore it can be used not only in ice halls, but in a large variety of engineering applications.

  15. Thermal neutron detection using a silicon pad detector and {sup 6}LiF removable converters

    SciTech Connect (OSTI)

    Barbagallo, Massimo; Cosentino, Luigi; Marchetta, Carmelo; Pappalardo, Alfio; Scire, Carlotta; Scire, Sergio; Schillaci, Maria; Vecchio, Gianfranco; Finocchiaro, Paolo; Forcina, Vittorio; Peerani, Paolo; Vaccaro, Stefano

    2013-03-15

    A semiconductor detector coupled with a neutron converter is a good candidate for neutron detection, especially for its compactness and reliability if compared with other devices, such as {sup 3}He tubes, even though its intrinsic efficiency is rather lower. In this paper we show a neutron detector design consisting of a 3 cm Multiplication-Sign 3 cm silicon pad detector coupled with one or two external {sup 6}LiF layers, enriched in {sup 6}Li at 95%, placed in contact with the Si active surfaces. This prototype, first characterized and tested at INFN Laboratori Nazionali del Sud and then at JRC Ispra, was successfully shown to detect thermal neutrons with the expected efficiency and an outstanding gamma rejection capability.

  16. Calibration of stormwater management model using flood extent data

    E-Print Network [OSTI]

    Han, Kunyeun; Kim, Youngjoo; Kim, Byunhyun; Famiglietti, James S; Sanders, Brett F

    2014-01-01

    publishing Calibration of stormwater management model usingin urbanised areas. the stormwater management model (SWMM)Issue WM1 Calibration of stormwater management model using ?

  17. Model-Based Transient Calibration Optimization for Next Generation...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Based Transient Calibration Optimization for Next Generation Diesel Engines Model-Based Transient Calibration Optimization for Next Generation Diesel Engines 2005 Diesel Engine...

  18. Digiquartz pressure transducer calibration test results

    SciTech Connect (OSTI)

    Bentzen, F.L.

    1980-12-01

    The safeguarding of strategic nuclear material in chemical fuel reprocessing plants requires the accurate determination of liquid level, which is translated to pressure through bubbler probes. To measure the pressure with sufficient accuracy requires transducers better than standard process units. The Paroscientific Inc. Digiquartz transducer meets the requirement when calibrated. Calibration was accomplished with an automatic data acquisition system using a Hewlett Packard 9825A computer and associated precision laboratory equipment and a Ruska DDR 6000 pressure calibrator. Data were taken from 0 to 15 psid over the range of 15 to 60/sup 0/C for 14 pressure transducers.

  19. Placement Optimization of Power Supply Pads Based on Locality Pingqiang Zhou, Vivek Mishra, and Sachin S. Sapatnekar

    E-Print Network [OSTI]

    Sapatnekar, Sachin

    Placement Optimization of Power Supply Pads Based on Locality Pingqiang Zhou, Vivek Mishra, and Sachin S. Sapatnekar Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, USA. {pingqiang, vivek, sachin}@umn.edu Abstract--This paper presents an efficient

  20. ANALYSIS OF THE SHEAR BEHAVIOR OF RAIL PAD ASSEMBLIES AS A COMPONENT OF THE CONCRETE SLEEPER FASTENING SYSTEM

    E-Print Network [OSTI]

    Barkan, Christopher P.L.

    Fastening System RAIL PAD ASSEMBLY LATERAL DISPLACEMENT FAILURE MODE AND EFFECT ANALYSIS (FMEA) INTRODUCTION life · FMEA is used to define, identify, evaluate and eliminate potential failures from the system · FMEA was used to guide the process of answering questions related to the component behavior and also

  1. PADS: A Policy Architecture for Distributed Storage Systems (Extended) Nalini Belaramani, Jiandan Zheng, Amol Nayate, Robert Soule,

    E-Print Network [OSTI]

    Grimm, Robert

    PADS: A Policy Architecture for Distributed Storage Systems (Extended) Nalini Belaramani, Jiandan architecture for build- ing distributed storage systems. A policy architecture has two aspects. First, a common, a structure for how policies, them- selves, should be specified. In the case of distributed storage systems

  2. Target-rate Tracking for Shale-gas Multi-well Pads by Scheduled Shut-ins

    E-Print Network [OSTI]

    Foss, Bjarne A.

    Target-rate Tracking for Shale-gas Multi-well Pads by Scheduled Shut-ins Brage R. Knudsen Bjarne, Yorktown Heights, NY, USA. Abstract: The recent success of shale-gas production relies on drilling of long caused by water accumulation in the wells. Shale-gas recovery requires a large number of wells in order

  3. Applying Calibration to Improve Uncertainty Assessment 

    E-Print Network [OSTI]

    Fondren, Mark Edward

    2013-08-02

    and its components, mainly calibration, are used for evaluating reliability. The system is general in the types of estimates and forecasts that it can monitor, including production, reserves, time, costs, and even quarterly earnings. Forecasts may...

  4. Ultraviolet laser calibration of drift chambers

    E-Print Network [OSTI]

    Elliott, Grant (Grant Andrew)

    2006-01-01

    We demonstrate the use of a focused ultraviolet laser as a track calibration source in drift chambers, and specifically in a small time projection chamber (TPC). Drift chambers such as TPCs reconstruct the trajectories of ...

  5. Calibration and Rating of Photovoltaics: Preprint

    SciTech Connect (OSTI)

    Emery, K.

    2012-06-01

    Rating the performance of photovoltaic (PV) modules is critical to determining the cost per watt, and efficiency is useful to assess the relative progress among PV concepts. Procedures for determining the efficiency for PV technologies from 1-sun to low concentration to high concentration are discussed. We also discuss the state of the art in primary and secondary calibration of PV reference cells used by calibration laboratories around the world. Finally, we consider challenges to rating PV technologies and areas for improvement.

  6. Calibration facility for environment dosimetry instruments

    SciTech Connect (OSTI)

    Bercea, Sorin; Celarel, Aurelia; Cenusa, Constantin [Horia Hulubei National Institute for Physics and Nuclear Engineering, 30 Reactorului St, Magurele, Jud Ilfov, P.O.B. MG-6, RO-077125 (Romania)

    2013-12-16

    In the last ten years, the nuclear activities, as well as the major nuclear events (see Fukushima accident) had an increasing impact on the environment, merely by contamination with radioactive materials. The most conferment way to quickly identify the presence of some radioactive elements in the environment, is to measure the dose-equivalent rate H. In this situation, information concerning the values of H due only to the natural radiation background must exist. Usually, the values of H due to the natural radiation background, are very low (?10{sup ?9} - 10{sup ?8} Sv/h). A correct measurement of H in this range involve a performing calibration of the measuring instruments in the measuring range corresponding to the natural radiation background lead to important problems due to the presence of the natural background itself the best way to overlap this difficulty is to set up the calibration stand in an area with very low natural radiation background. In Romania, we identified an area with such special conditions at 200 m dept, in a salt mine. This paper deals with the necessary requirements for such a calibration facility, as well as with the calibration stand itself. The paper includes also, a description of the calibration stand (and images) as well as the radiological and metrological parameters. This calibration facilities for environment dosimetry is one of the few laboratories in this field in Europe.

  7. Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Tonopah Airport, Nye County, Nevada

    SciTech Connect (OSTI)

    J. Engelbrecht; I. Kavouras; D Campbell; S. Campbell; S. Kohl, D. Shafer

    2008-08-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Tonopah Airport, Beatty, Rachel, Caliente, Pahranagat NWR, Crater Flat, and the Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

  8. Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Tonopah Airport, Nye County, Nevada

    SciTech Connect (OSTI)

    J. Engelbrecht; I. Kavouras; D. Campbell; S. Campbell; S. Kohl; D. Shafer

    2009-04-02

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Tonopah Airport, Beatty, Rachel, Caliente, Pahranagat NWR, Crater Flat, and the Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

  9. Calibration-free optical chemical sensors

    DOE Patents [OSTI]

    DeGrandpre, Michael D.

    2006-04-11

    An apparatus and method for taking absorbance-based chemical measurements are described. In a specific embodiment, an indicator-based pCO2 (partial pressure of CO2) sensor displays sensor-to-sensor reproducibility and measurement stability. These qualities are achieved by: 1) renewing the sensing solution, 2) allowing the sensing solution to reach equilibrium with the analyte, and 3) calculating the response from a ratio of the indicator solution absorbances which are determined relative to a blank solution. Careful solution preparation, wavelength calibration, and stray light rejection also contribute to this calibration-free system. Three pCO2 sensors were calibrated and each had response curves which were essentially identical within the uncertainty of the calibration. Long-term laboratory and field studies showed the response had no drift over extended periods (months). The theoretical response, determined from thermodynamic characterization of the indicator solution, also predicted the observed calibration-free performance.

  10. Calibration Monitoring for Sensor Calibration Interval Extension: Gaps in the Current Science Base

    SciTech Connect (OSTI)

    Coble, Jamie B.; Ramuhalli, Pradeep; Meyer, Ryan M.; Hashemian, Hash; Shumaker, Brent; Cummins, Dara

    2012-10-09

    Currently in the United States, periodic sensor recalibration is required for all safety-related sensors, typically occurring at every refueling outage, and it has emerged as a critical path item for shortening outage duration in some plants. International application of calibration monitoring has shown that sensors may operate for longer periods within calibration tolerances. This issue is expected to also be important as the United States looks to the next generation of reactor designs (such as small modular reactors and advanced concepts), given the anticipated longer refueling cycles, proposed advanced sensors, and digital instrumentation and control systems. Online monitoring (OLM) can be employed to identify those sensors that require calibration, allowing for calibration of only those sensors that need it. The U.S. Nuclear Regulatory Commission (NRC) accepted the general concept of OLM for sensor calibration monitoring in 2000, but no U.S. plants have been granted the necessary license amendment to apply it. This paper summarizes a recent state-of-the-art assessment of online calibration monitoring in the nuclear power industry, including sensors, calibration practice, and OLM algorithms. This assessment identifies key research needs and gaps that prohibit integration of the NRC-approved online calibration monitoring system in the U.S. nuclear industry. Several technical needs were identified, including an understanding of the impacts of sensor degradation on measurements for both conventional and emerging sensors; the quantification of uncertainty in online calibration assessment; determination of calibration acceptance criteria and quantification of the effect of acceptance criteria variability on system performance; and assessment of the feasibility of using virtual sensor estimates to replace identified faulty sensors in order to extend operation to the next convenient maintenance opportunity.

  11. A Review of Sensor Calibration Monitoring for Calibration Interval Extension in Nuclear Power Plants

    SciTech Connect (OSTI)

    Coble, Jamie B.; Meyer, Ryan M.; Ramuhalli, Pradeep; Bond, Leonard J.; Hashemian, Hash; Shumaker, Brent; Cummins, Dara

    2012-08-31

    Currently in the United States, periodic sensor recalibration is required for all safety-related sensors, typically occurring at every refueling outage, and it has emerged as a critical path item for shortening outage duration in some plants. Online monitoring can be employed to identify those sensors that require calibration, allowing for calibration of only those sensors that need it. International application of calibration monitoring, such as at the Sizewell B plant in United Kingdom, has shown that sensors may operate for eight years, or longer, within calibration tolerances. This issue is expected to also be important as the United States looks to the next generation of reactor designs (such as small modular reactors and advanced concepts), given the anticipated longer refueling cycles, proposed advanced sensors, and digital instrumentation and control systems. The U.S. Nuclear Regulatory Commission (NRC) accepted the general concept of online monitoring for sensor calibration monitoring in 2000, but no U.S. plants have been granted the necessary license amendment to apply it. This report presents a state-of-the-art assessment of online calibration monitoring in the nuclear power industry, including sensors, calibration practice, and online monitoring algorithms. This assessment identifies key research needs and gaps that prohibit integration of the NRC-approved online calibration monitoring system in the U.S. nuclear industry. Several needs are identified, including the quantification of uncertainty in online calibration assessment; accurate determination of calibration acceptance criteria and quantification of the effect of acceptance criteria variability on system performance; and assessment of the feasibility of using virtual sensor estimates to replace identified faulty sensors in order to extend operation to the next convenient maintenance opportunity. Understanding the degradation of sensors and the impact of this degradation on signals is key to developing technical basis to support acceptance criteria and set point decisions, particularly for advanced sensors which do not yet have a cumulative history of operating performance.

  12. Calibrating transport lines using LOCO techniques

    SciTech Connect (OSTI)

    Yves Roblin

    2011-09-01

    With the 12GeV upgrade underway at CEBAF, there is a need to re-characterize the beamlines after the modifications made to it to accommodate running at higher energies. We present a linear perturbation approach to calibrating the optics model of transport lines. This method is adapted from the LOCO method in use for storage rings. We consider the effect of quadrupole errors, dipole construction errors as well as beam position monitors and correctors calibrations. The ideal model is expanded to first order in Taylor series of the quadrupole errors. A set of difference orbits obtained by exciting the correctors along the beamline is taken, yielding the measured response matrix. An iterative procedure is invoked and the quadrupole errors as well as beam position monitors and corrector calibration factors are obtained. Here we present details of the method and results of first measurements at CEBAF in early 2011.

  13. Calibrated Hydrothermal Parameters, Barrow, Alaska, 2013

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Atchley, Adam; Painter, Scott; Harp, Dylan; Coon, Ethan; Wilson, Cathy; Liljedahl, Anna; Romanovsky, Vladimir

    A model-observation-experiment process (ModEx) is used to generate three 1D models of characteristic micro-topographical land-formations, which are capable of simulating present active thaw layer (ALT) from current climate conditions. Each column was used in a coupled calibration to identify moss, peat and mineral soil hydrothermal properties to be used in up-scaled simulations. Observational soil temperature data from a tundra site located near Barrow, AK (Area C) is used to calibrate thermal properties of moss, peat, and sandy loam soil to be used in the multiphysics Advanced Terrestrial Simulator (ATS) models. Simulation results are a list of calibrated hydrothermal parameters for moss, peat, and mineral soil hydrothermal parameters.

  14. The Fourth VLBA Calibrator Survey - VCS4

    E-Print Network [OSTI]

    L. Petrov; Y. Y. Kovalev; E. Fomalont; D. Gordon

    2005-10-24

    This paper presents the fourth extension to the Very Long Baseline Array (VLBA) Calibrator Survey, containing 258 new sources not previously observed with very long baseline interferometry (VLBI). This survey, based on three 24 hour VLBA observing sessions, fills remaining areas on the sky above declination -40 degrees where the calibrator density is less than one source within a 4 degree radius disk at any given direction. The share of these area was reduced from 4.6% to 1.9%. Source positions were derived from astrometric analysis of group delays determined at 2.3 and 8.6 GHz frequency bands using the Calc/Solve software package. The VCS4 catalogue of source positions, plots of correlated flux density versus projected baseline length, contour plots and fits files of naturally weighted CLEAN images, as well as calibrated visibility function files are available on the Web at http://gemini.gsfc.nasa.gov/vcs4 .

  15. Calibrated Hydrothermal Parameters, Barrow, Alaska, 2013

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Atchley, Adam; Painter, Scott; Harp, Dylan; Coon, Ethan; Wilson, Cathy; Liljedahl, Anna; Romanovsky, Vladimir

    2015-01-29

    A model-observation-experiment process (ModEx) is used to generate three 1D models of characteristic micro-topographical land-formations, which are capable of simulating present active thaw layer (ALT) from current climate conditions. Each column was used in a coupled calibration to identify moss, peat and mineral soil hydrothermal properties to be used in up-scaled simulations. Observational soil temperature data from a tundra site located near Barrow, AK (Area C) is used to calibrate thermal properties of moss, peat, and sandy loam soil to be used in the multiphysics Advanced Terrestrial Simulator (ATS) models. Simulation results are a list of calibrated hydrothermal parameters for moss, peat, and mineral soil hydrothermal parameters.

  16. MEMS packaging with etching and thinning of lid wafer to form lids and expose device wafer bond pads

    DOE Patents [OSTI]

    Chanchani, Rajen; Nordquist, Christopher; Olsson, Roy H; Peterson, Tracy C; Shul, Randy J; Ahlers, Catalina; Plut, Thomas A; Patrizi, Gary A

    2013-12-03

    In wafer-level packaging of microelectromechanical (MEMS) devices a lid wafer is bonded to a MEMS wafer in a predermined aligned relationship. Portions of the lid wafer are removed to separate the lid wafer into lid portions that respectively correspond in alignment with MEMS devices on the MEMS wafer, and to expose areas of the MEMS wafer that respectively contain sets of bond pads respectively coupled to the MEMS devices.

  17. Electric Ground Support Equipment Advanced Battery Technology Demonstration Project at the Ontario Airport

    SciTech Connect (OSTI)

    Tyler Gray; Jeremy Diez; Jeffrey Wishart; James Francfort

    2013-07-01

    The intent of the electric Ground Support Equipment (eGSE) demonstration is to evaluate the day-to-day vehicle performance of electric baggage tractors using two advanced battery technologies to demonstrate possible replacements for the flooded lead-acid (FLA) batteries utilized throughout the industry. These advanced battery technologies have the potential to resolve barriers to the widespread adoption of eGSE deployment. Validation testing had not previously been performed within fleet operations to determine if the performance of current advanced batteries is sufficient to withstand the duty cycle of electric baggage tractors. This report summarizes the work performed and data accumulated during this demonstration in an effort to validate the capabilities of advanced battery technologies. This report summarizes the work performed and data accumulated during this demonstration in an effort to validate the capabilities of advanced battery technologies. The demonstration project also grew the relationship with Southwest Airlines (SWA), our demonstration partner at Ontario International Airport (ONT), located in Ontario, California. The results of this study have encouraged a proposal for a future demonstration project with SWA.

  18. An Archaeological Survey for Suemaur Exploration & Production, LLC's Hoskins Mound-Olympia and Mckinley Prospects Well Pad Sites and Access Roads in Brazoria County Texas 

    E-Print Network [OSTI]

    Moore, William

    2015-07-30

    An archaeological survey of two proposed well pad sites and access roads in the Brazoria National Wildlife Refuge in south Brazoria County, Texas was performed by Brazos Valley Research Associates (BVRA) on February 5, ...

  19. An Archaeological Survey for Suemaur Exploration & Production, LLC's Hoskins Mound-Pocono Prospect Well Pad Site and Access Road in Brazoria County Texas 

    E-Print Network [OSTI]

    Moore, William

    2015-07-30

    An archaeological survey of a proposed well pad site and access road in the Brazoria National Wildlife Refuge in south Brazoria County, Texas was performed by Brazos Valley Research Associates (BVRA) on February 5, 2010. The area investigated...

  20. Crop physiology calibration in the CLM

    SciTech Connect (OSTI)

    Bilionis, I.; Drewniak, B. A.; Constantinescu, E. M.

    2015-04-15

    Farming is using more of the land surface, as population increases and agriculture is increasingly applied for non-nutritional purposes such as biofuel production. This agricultural expansion exerts an increasing impact on the terrestrial carbon cycle. In order to understand the impact of such processes, the Community Land Model (CLM) has been augmented with a CLM-Crop extension that simulates the development of three crop types: maize, soybean, and spring wheat. The CLM-Crop model is a complex system that relies on a suite of parametric inputs that govern plant growth under a given atmospheric forcing and available resources. CLM-Crop development used measurements of gross primary productivity (GPP) and net ecosystem exchange (NEE) from AmeriFlux sites to choose parameter values that optimize crop productivity in the model. In this paper, we calibrate these parameters for one crop type, soybean, in order to provide a faithful projection in terms of both plant development and net carbon exchange. Calibration is performed in a Bayesian framework by developing a scalable and adaptive scheme based on sequential Monte Carlo (SMC). The model showed significant improvement of crop productivity with the new calibrated parameters. We demonstrate that the calibrated parameters are applicable across alternative years and different sites.

  1. Calibration of the MACHO Photometry Database

    E-Print Network [OSTI]

    C. Alcock; R. A. Allsman; D. R. Alves; T. S. Axelrod; A. C. Becker; D. P. Bennett; K. H. Cook; A. J. Drake; K. C. Freeman; K. Griest; M. J. Lehner; S. L. Marshall; D. Minniti; B. A. Peterson; M. R. Pratt; C. A. Nelson; P. J. Quinn; C. W. Stubbs; W. Sutherland; A. B. Tomaney; D. L. Welch

    1999-09-14

    The MACHO Project is a microlensing survey that monitors the brightnesses of 60 million stars in the Large Magellanic Cloud (LMC), Small Magellanic Cloud, and Galactic bulge. Our database presently contains about 80 billion photometric measurements, a significant fraction of all astronomical photometry. We describe the calibration of MACHO two-color photometry and transformation to the standard Kron-Cousins V and R system. Calibrated MACHO photometry may be properly compared with all other observations on the Kron-Cousins standard system, enhancing the astrophysical value of these data. For 9 million stars in the LMC bar, independent photometric measurements of 20,000 stars with V photometry with published photometric sequences and new Hubble Space Telescope observations shows agreement. The current calibration zero-point uncertainty for the remainder of the MACHO photometry database is estimated to be +- 0.10 mag in V or R and +-0.04 mag in (V-R). We describe the first application of calibrated MACHO photometry data: the construction of a color-magnitude diagram used to calculate our experimental sensitivity to detect microlensing in the LMC.

  2. Jet energy calibration at the LHC

    E-Print Network [OSTI]

    Schwartzman, Ariel

    2015-01-01

    Jets are one of the most prominent physics signatures of high energy proton proton (p-p) collisions at the Large Hadron Collider (LHC). They are key physics objects for precision measurements and searches for new phenomena. This review provides an overview of the reconstruction and calibration of jets at the LHC during its first Run. ATLAS and CMS developed different approaches for the reconstruction of jets, but use similar methods for the energy calibration. ATLAS reconstructs jets utilizing input signals from their calorimeters and use charged particle tracks to refine their energy measurement and suppress the effects of multiple p-p interactions (pileup). CMS, instead, combines calorimeter and tracking information to build jets from particle flow objects. Jets are calibrated using Monte Carlo (MC) simulations and a residual in situ calibration derived from collision data is applied to correct for the differences in jet response between data and Monte Carlo. Large samples of dijet, Z+jets, and photon+jet e...

  3. Calibration of the Milagro Cosmic Ray Telescope

    E-Print Network [OSTI]

    Atkins, R; Berley, D; Chen, M L; Coyne, D G; Delay, R S; Dingus, B L; Dorfan, D E; Ellsworth, R W; Evans, D; Falcone, A D; Fleysher, L; Fleysher, R; Gisler, G; Goodman, J A; Haines, T J; Hoffman, C M; Hugenberger, S; Kelley, L A; Leonor, I; Macri, J R; McConnell, M; McCullough, J F; McEnery, J E; Miller, R S; Mincer, A I; Morales, M F; Némethy, P; Ryan, J M; Schneider, M; Shen, B; Shoup, A L; Sinnis, G; Smith, A J; Sullivan, G W; Thompson, T N; Tümer, T O; Wang, K; Wascko, M O; Westerhoff, S; Williams, D A; Yang, T; Yodh, G B

    1999-01-01

    The Milagro detector is an air shower array which uses the water Cherenkov technique and is capable of continuously monitoring the sky at energies near 1 TeV. The detector consists of 20000 metric tons of pure water instrumented with 723 photo-multiplier tubes (PMTs). The PMTs are arranged in a two-layer structure on a lattice of 3 m spacing covering 5000 $m^2$ area. The direction of the shower is determined from the relative timing of the PMT signals, necessitating a common time reference and amplitude slewing corrections to improve the time resolution. The calibration system to provide these consists of a pulsed laser driving 30 diffusing light sources deployed in the pond to allow cross-calibration of the PMTs. The system is capable of calibrating times and the pulse-heights from the PMTs using the time-over-threshold technique. The absolute energy scale is provided using single muons passing through the detector. The description of the calibration system of the Milagro detector and its prototype Milagrito...

  4. Calibration of the Milagro Cosmic Ray Telescope

    E-Print Network [OSTI]

    R. Atkins; W. Benbow; D. Berley; M. -L. Chen; D. G. Coyne; R. S. Delay; B. L. Dingus; D. E. Dorfan; R. W. Ellsworth; D. Evans; A. Falcone; L. Fleysher; R. Fleysher; G. Gisler; J. A. Goodman; T. J. Haines; C. M. Hoffman; S. Hugenberger; L. A. Kelley; I. Leonor; J. Macri; M. McConnell; J. F. McCullough; J. E. McEnery; R. S. Miller; A. I. Mincer; M. F. Morales; P. Nemethy; J. M. Ryan; M. Schneider; B. Shen; A. Shoup; G. Sinnis; A. J. Smith; G. W. Sullivan; T. N. Thompson; O. T. Tumer; K. Wang; M. O. Wascko; S. Westerhoff; D. A. Williams; T. Yang; G. B. Yodh

    1999-06-25

    The Milagro detector is an air shower array which uses the water Cherenkov technique and is capable of continuously monitoring the sky at energies near 1 TeV. The detector consists of 20000 metric tons of pure water instrumented with 723 photo-multiplier tubes (PMTs). The PMTs are arranged in a two-layer structure on a lattice of 3 m spacing covering 5000 $m^2$ area. The direction of the shower is determined from the relative timing of the PMT signals, necessitating a common time reference and amplitude slewing corrections to improve the time resolution. The calibration system to provide these consists of a pulsed laser driving 30 diffusing light sources deployed in the pond to allow cross-calibration of the PMTs. The system is capable of calibrating times and the pulse-heights from the PMTs using the time-over-threshold technique. The absolute energy scale is provided using single muons passing through the detector. The description of the calibration system of the Milagro detector and its prototype Milagrito will be presented.

  5. Crop physiology calibration in the CLM

    SciTech Connect (OSTI)

    Bilionis, I. [Argonne National Lab., IL (United States). Mathematics and Computer Science Div.; Drewniak, B. A. [Argonne National Lab., IL (United States). Environmental Science Div.; Constantinescu, E. M. [Argonne National Lab., IL (United States). Mathematics and Computer Science Div.

    2015-01-01

    Farming is using more of the land surface, as population increases and agriculture is increasingly applied for non-nutritional purposes such as biofuel production. This agricultural expansion exerts an increasing impact on the terrestrial carbon cycle. In order to understand the impact of such processes, the Community Land Model (CLM) has been augmented with a CLM-Crop extension that simulates the development of three crop types: maize, soybean, and spring wheat. The CLM-Crop model is a complex system that relies on a suite of parametric inputs that govern plant growth under a given atmospheric forcing and available resources. CLM-Crop development used measurements of gross primary productivity (GPP) and net ecosystem exchange (NEE) from AmeriFlux sites to choose parameter values that optimize crop productivity in the model. In this paper, we calibrate these parameters for one crop type, soybean, in order to provide a faithful projection in terms of both plant development and net carbon exchange. Calibration is performed in a Bayesian framework by developing a scalable and adaptive scheme based on sequential Monte Carlo (SMC). The model showed significant improvement of crop productivity with the new calibrated parameters. We demonstrate that the calibrated parameters are applicable across alternative years and different sites.

  6. Planck 2015 results. V. LFI calibration

    E-Print Network [OSTI]

    Ade, P A R; Ashdown, M; Aumont, J; Baccigalupi, C; Banday, A J; Barreiro, R B; Bartolo, N; Battaglia, P; Battaner, E; Benabed, K; Benoît, A; Benoit-Lévy, A; Bernard, J -P; Bersanelli, M; Bielewicz, P; Bock, J J; Bonaldi, A; Bonavera, L; Bond, J R; Borrill, J; Bouchet, F R; Bucher, M; Burigana, C; Butler, R C; Calabrese, E; Cardoso, J -F; Catalano, A; Chamballu, A; Christensen, P R; Colombi, S; Colombo, L P L; Crill, B P; Curto, A; Cuttaia, F; Danese, L; Davies, R D; Davis, R J; de Bernardis, P; de Rosa, A; de Zotti, G; Delabrouille, J; Dickinson, C; Diego, J M; Dole, H; Donzelli, S; Doré, O; Douspis, M; Ducout, A; Dupac, X; Efstathiou, G; Elsner, F; Enßlin, T A; Eriksen, H K; Fergusson, J; Finelli, F; Forni, O; Frailis, M; Franceschi, E; Frejsel, A; Galeotta, S; Galli, S; Ganga, K; Giard, M; Giraud-Héraud, Y; Gjerløw, E; González-Nuevo, J; Górski, K M; Gratton, S; Gregorio, A; Gruppuso, A; Hansen, F K; Hanson, D; Harrison, D L; Henrot-Versillé, S; Herranz, D; Hildebrandt, S R; Hivon, E; Hobson, M; Holmes, W A; Hornstrup, A; Hovest, W; Huffenberger, K M; Hurier, G; Jaffe, A H; Jaffe, T R; Juvela, M; Keihänen, E; Keskitalo, R; Kisner, T S; Knoche, J; Krachmalnicoff, N; Kunz, M; Kurki-Suonio, H; Lagache, G; Lähteenmäki, A; Lamarre, J -M; Lasenby, A; Lattanzi, M; Lawrence, C R; Leahy, J P; Leonardi, R; Lesgourgues, J; Levrier, F; Liguori, M; Lilje, P B; Linden-Vørnle, M; López-Caniego, M; Lubin, P M; Macías-Pérez, J F; Maggio, G; Maino, D; Mandolesi, N; Mangilli, A; Maris, M; Martin, P G; Martínez-González, E; Masi, S; Matarrese, S; McGehee, P; Meinhold, P R; Melchiorri, A; Mendes, L; Mennella, A; Migliaccio, M; Mitra, S; Montier, L; Morgante, G; Mortlock, D; Moss, A; Munshi, D; Murphy, J A; Naselsky, P; Nati, F; Natoli, P; Netterfield, C B; Nørgaard-Nielsen, H U; Novikov, D; Novikov, I; Paci, F; Pagano, L; Pajot, F; Paoletti, D; Partridge, B; Pasian, F; Patanchon, G; Pearson, T J; Peel, M; Perdereau, O; Perotto, L; Perrotta, F; Pettorino, V; Piacentini, F; Pierpaoli, E; Pietrobon, D; Pointecouteau, E; Polenta, G; Pratt, G W; Prézeau, G; Prunet, S; Puget, J -L; Rachen, J P; Rebolo, R; Reinecke, M; Remazeilles, M; Renzi, A; Rocha, G; Romelli, E; Rosset, C; Rossetti, M; Roudier, G; Rubiño-Martín, J A; Rusholme, B; Sandri, M; Santos, D; Savelainen, M; Scott, D; Seiffert, M D; Shellard, E P S; Spencer, L D; Stolyarov, V; Sutton, D; Suur-Uski, A -S; Sygnet, J -F; Tauber, J A; Tavagnacco, D; Terenzi, L; Toffolatti, L; Tomasi, M; Tristram, M; Tucci, M; Tuovinen, J; Türler, M; Umana, G; Valenziano, L; Valiviita, J; Van Tent, B; Vassallo, T; Vielva, P; Villa, F; Wade, L A; Wandelt, B D; Watson, R; Wehus, I K; Wilkinson, A; Yvon, D; Zacchei, A; Zonca, A

    2015-01-01

    We present a description of the pipeline used to calibrate the Planck Low Frequency Instrument (LFI) timelines into thermodynamic temperatures for the Planck 2015 data release, covering 4 years of uninterrupted operations. As in the 2013 data release, our calibrator is provided by the spin-synchronous modulation of the CMB dipole, exploiting both the orbital and solar components. Our 2015 LFI analysis provides an independent Solar dipole estimate in excellent agreement with that of HFI and within $1\\sigma$ (0.3 % in amplitude) of the WMAP value. This 0.3 % shift in the peak-to-peak dipole temperature from WMAP and a global overhaul of the iterative calibration code increases the overall level of the LFI maps by 0.45 % (30 GHz), 0.64 % (44 GHz), and 0.82 % (70 GHz) in temperature with respect to the 2013 Planck data release, thus reducing the discrepancy with the power spectrum measured by WMAP. We estimate that the LFI calibration uncertainty is at the level of 0.20 % for the 70 GHz map, 0.26 % for the 44 GHz...

  7. Beam calibration of radio telescopes with drones

    E-Print Network [OSTI]

    Chang, Chihway; Refregier, Alexandre; Amara, Adam; Glauser, Adrian; Casura, Sarah

    2015-01-01

    We present a multi-frequency far-field beam map for the 5m dish telescope at the Bleien Observatory measured using a commercially available drone. We describe the hexacopter drone used in this experiment, the design of the flight pattern, and the data analysis scheme. This is the first application of this calibration method to a single dish radio telescope in the far-field. The high signal-to-noise data allows us to characterise the beam pattern with high accuracy out to at least the 4th side-lobe. The resulting 2D beam pattern is compared with that derived from a more traditional calibration approach using an astronomical calibration source. We discuss the advantages of this method compared to other beam calibration methods. Our results show that this drone-based technique is very promising for ongoing and future radio experiments, where the knowledge of the beam pattern is key to obtaining high-accuracy cosmological and astronomical measurements.

  8. Crop physiology calibration in the CLM

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Bilionis, I.; Drewniak, B. A.; Constantinescu, E. M.

    2015-04-15

    Farming is using more of the land surface, as population increases and agriculture is increasingly applied for non-nutritional purposes such as biofuel production. This agricultural expansion exerts an increasing impact on the terrestrial carbon cycle. In order to understand the impact of such processes, the Community Land Model (CLM) has been augmented with a CLM-Crop extension that simulates the development of three crop types: maize, soybean, and spring wheat. The CLM-Crop model is a complex system that relies on a suite of parametric inputs that govern plant growth under a given atmospheric forcing and available resources. CLM-Crop development used measurementsmore »of gross primary productivity (GPP) and net ecosystem exchange (NEE) from AmeriFlux sites to choose parameter values that optimize crop productivity in the model. In this paper, we calibrate these parameters for one crop type, soybean, in order to provide a faithful projection in terms of both plant development and net carbon exchange. Calibration is performed in a Bayesian framework by developing a scalable and adaptive scheme based on sequential Monte Carlo (SMC). The model showed significant improvement of crop productivity with the new calibrated parameters. We demonstrate that the calibrated parameters are applicable across alternative years and different sites.« less

  9. Downstream hydraulic geometry relations: 2. Calibration and testing 

    E-Print Network [OSTI]

    Singh, Vijay P.; Yang, Chih Ted; Deng, Zhi-Qiang

    2003-12-04

    Using 456 data sets under bank-full conditions obtained from various sources, the geometric relations, derived in part 1 [ Singh et al., 2003 ], are calibrated and verified using the split sampling approach. The calibration of parameters shows...

  10. Definition of energy-calibrated spectra for national reachback

    SciTech Connect (OSTI)

    Kunz, Christopher L.; Hertz, Kristin L.

    2014-01-01

    Accurate energy calibration is critical for the timeliness and accuracy of analysis results of spectra submitted to National Reachback, particularly for the detection of threat items. Many spectra submitted for analysis include either a calibration spectrum using 137Cs or no calibration spectrum at all. The single line provided by 137Cs is insufficient to adequately calibrate nonlinear spectra. A calibration source that provides several lines that are well-spaced, from the low energy cutoff to the full energy range of the detector, is needed for a satisfactory energy calibration. This paper defines the requirements of an energy calibration for the purposes of National Reachback, outlines a method to validate whether a given spectrum meets that definition, discusses general source considerations, and provides a specific operating procedure for calibrating the GR-135.

  11. Test surfaces useful for calibration of surface profilometers

    SciTech Connect (OSTI)

    Yashchuk, Valeriy V; McKinney, Wayne R; Takacs, Peter Z

    2013-12-31

    The present invention provides for test surfaces and methods for calibration of surface profilometers, including interferometric and atomic force microscopes. Calibration is performed using a specially designed test surface, or the Binary Pseudo-random (BPR) grating (array). Utilizing the BPR grating (array) to measure the power spectral density (PSD) spectrum, the profilometer is calibrated by determining the instrumental modulation transfer.

  12. CALIBRATION OF PHOTOVOLTAIC MODULE PERFORMANCE MODELS USING MONITORED SYSTEM DATA

    E-Print Network [OSTI]

    CALIBRATION OF PHOTOVOLTAIC MODULE PERFORMANCE MODELS USING MONITORED SYSTEM DATA Clifford W Facilities Inc, Tokyo, Japan, hakuta22@ntt-f.co.jp ABSTRACT: Calibration of a photovoltaic module performance and validate methods to calibrate the Sandia Photovoltaic Array Performance Model and the California Energy

  13. NIST Measurement Services: Natural Gas Flow Calibration Service (NGFCS)

    E-Print Network [OSTI]

    NIST Measurement Services: Natural Gas Flow Calibration Service (NGFCS) NIST Special Publication of Standards and Technology #12;i Table of Contents for the Natural Gas Flowmeter Calibration Service (NGFCS;1 Abstract This document describes NIST's high pressure natural gas flow calibration service (NGFCS). Flow

  14. Microsoft PowerPoint - To NETL Albany Site from Eugene, Oregon Airport Directions.ppt [Compatibility Mode]

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration wouldMass map shines light on darkMicroorganismsnowReport ARM28 MarchEugene, Oregon Airport 1.

  15. Microsoft PowerPoint - To NETL Albany Site from Portland, Oregon Airport (PDX) Directions.ppt [Compatibility Mode]

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration wouldMass map shines light on darkMicroorganismsnowReport ARM28 MarchEugene, Oregon Airport

  16. Calibrations of a tritium extraction facility

    SciTech Connect (OSTI)

    Bretscher, M.M.; Oliver, B.M.; Farrar, H. IV

    1983-01-01

    A tritium extraction facility has been built for the purpose of measuring the absolute tritium concentration in neutron-irradiated lithium metal samples. Two independent calibration procedures have been used to determine what fraction, if any, of tritium is lost during the extraction process. The first procedure compares independently measured /sup 4/He and /sup 3/H concentrations from the /sup 6/Li(n,..cap alpha..)T reaction. The second procedure compared measured /sup 6/Li(n,..cap alpha..)T//sup 197/Au (n,..gamma..)/sup 198/Au thermal neutron reaction rate ratios with those obtained from Monte Carlo calculations using well-known cross sections. Both calibration methods show that within experimental errors (approx. 1.5%) no tritium is lost during the extraction process.

  17. Calibration method for video and radiation imagers

    DOE Patents [OSTI]

    Cunningham, Mark F. (Oak Ridge, TN); Fabris, Lorenzo (Knoxville, TN); Gee, Timothy F. (Oak Ridge, TN); Goddard, Jr., James S. (Knoxville, TN); Karnowski, Thomas P. (Knoxville, TN); Ziock, Klaus-peter (Clinton, TN)

    2011-07-05

    The relationship between the high energy radiation imager pixel (HERIP) coordinate and real-world x-coordinate is determined by a least square fit between the HERIP x-coordinate and the measured real-world x-coordinates of calibration markers that emit high energy radiation imager and reflect visible light. Upon calibration, a high energy radiation imager pixel position may be determined based on a real-world coordinate of a moving vehicle. Further, a scale parameter for said high energy radiation imager may be determined based on the real-world coordinate. The scale parameter depends on the y-coordinate of the moving vehicle as provided by a visible light camera. The high energy radiation imager may be employed to detect radiation from moving vehicles in multiple lanes, which correspondingly have different distances to the high energy radiation imager.

  18. Calibration of a SCARA robot manipulator 

    E-Print Network [OSTI]

    Brock, Timothy Boland

    1989-01-01

    ? the ? shelf equipment. One exception to this is the laser interferometer experiment which was primarily used as a verification tool. Micro computer based software was used for data analysis and parameter identification. Results of the calibration... between the calculated manipulator X ? positions and the actual manipulator X ? positions. Results of this verification test indicate that the parameters found using the stretched wire experiment could be used to predict the correct joint angles for any...

  19. Two Approaches to Calibration in Metrology

    SciTech Connect (OSTI)

    Campanelli, Mark

    2014-04-01

    Inferring mathematical relationships with quantified uncertainty from measurement data is common to computational science and metrology. Sufficient knowledge of measurement process noise enables Bayesian inference. Otherwise, an alternative approach is required, here termed compartmentalized inference, because collection of uncertain data and model inference occur independently. Bayesian parameterized model inference is compared to a Bayesian-compatible compartmentalized approach for ISO-GUM compliant calibration problems in renewable energy metrology. In either approach, model evidence can help reduce model discrepancy.

  20. RUNNING HEAD: THE FOSSIL CALIBRATION DATABASE Title: The Fossil Calibration Database, A New Resource for Divergence Dating

    E-Print Network [OSTI]

    Benton, Michael

    1 RUNNING HEAD: THE FOSSIL CALIBRATION DATABASE Title: The Fossil Calibration Database, A New Street NW, Washington, DC, 20059, USA; 19 Centre of Evolutionary and Ecological Studies, Marine Evolution continually lest they become obsolete. Here, we announce the Fossil Calibration Database (http

  1. The Fifth VLBA Calibrator Survey: VCS5

    E-Print Network [OSTI]

    Y. Y. Kovalev; L. Petrov; E. B. Fomalont; D. Gordon

    2006-11-21

    This paper presents the fifth part of the Very Long Baseline Array (VLBA) Calibrator Survey (VCS), containing 569 sources not observed previously with very long baseline interferometry in geodetic or absolute astrometry programs. This campaign has two goals: (i) to observe additional sources which, together with previous survey results, form a complete sample, (ii) to find new strong sources suitable as phase calibrators. This VCS extension was based on three 24-hour VLBA observing sessions in 2005. It detected almost all extragalactic flat-spectrum sources with correlated flux density greater than 200 mJy at 8.6 GHz above declination -30 degrees which were not observed previously. Source positions with milliarcsecond accuracy were derived from astrometric analysis of ionosphere-free combinations of group delays determined from the 2.3 GHz and 8.6 GHz frequency bands. The VCS5 catalog of source positions, plots of correlated flux density versus projected baseline length, contour plots and FITS files of naturally weighted CLEAN images, as well as calibrated visibility function files are available on the Web at http://vlbi.gsfc.nasa.gov/vcs5

  2. The Sixth VLBA Calibrator Survey: VCS6

    E-Print Network [OSTI]

    L. Petrov; Y. Y. Kovalev; E. B. Fomalont; D. Gordon

    2008-07-21

    This paper presents the sixth part to the Very Long Baseline Array (VLBA) Calibrator Survey. It contains the positions and maps of 264 sources of which 169 were not previously observed with very long baseline interferometry (VLBI). This survey, based on two 24 hour VLBA observing sessions, was focused on 1) improving positions of 95 sources from previous VLBA Calibrator surveys that were observed either with very large a priori position errors or were observed not long enough to get reliable positions and 2) observing remaining new flat-spectrum sources with predicted correlated flux density in the range 100-200 mJy that were not observed in previous surveys. Source positions were derived from astrometric analysis of group delays determined at the 2.3 and 8.6 GHz frequency bands using the Calc/Solve software package. The VCS6 catalogue of source positions, plots of correlated flux density versus projected baseline length, contour plots and fits files of naturally weighted CLEAN images, as well as calibrated visibility function files are available on the Web at http://vlbi.gsfc.nasa.gov/vcs6

  3. Calibration of a Thomson scattering diagnostic for fluctuation measurements

    SciTech Connect (OSTI)

    Stephens, H. D.; Borchardt, M. T.; Den Hartog, D. J.; Falkowski, A. F.; Holly, D. J.; O'Connell, R.; Reusch, J. A.

    2008-10-15

    Detailed calibrations of the Madison Symmetric Torus polychromator Thomson scattering system have been made suitable for electron temperature fluctuation measurements. All calibrations have taken place focusing on accuracy, ease of use and repeatability, and in situ measurements wherever possible. Novel calibration processes have been made possible with an insertable integrating sphere (ISIS), using an avalanche photodiode (APD) as a reference detector and optical parametric oscillator (OPO). Discussed are a novel in situ spatial calibration with the use of the ISIS, the use of an APD as a reference detector to streamline the APD calibration process, a standard dc spectral calibration, and in situ pulsed spectral calibration made possible with a combination of an OPO as a light source, the ISIS, and an APD used as a reference detector. In addition a relative quantum efficiency curve for the APDs is obtained to aid in uncertainty analysis.

  4. Branch cuts of Stokes wave on deep water. Part I: Numerical solution and Pad\\'e approximation

    E-Print Network [OSTI]

    Dyachenko, S A; Korotkevich, A O

    2015-01-01

    Complex analytical structure of Stokes wave for two-dimensional potential flow of the ideal incompressible fluid with free surface and infinite depth is analyzed. Stokes wave is the fully nonlinear periodic gravity wave propagating with the constant velocity. Simulations with the quadruple and variable precisions are performed to find Stokes wave with high accuracy and study the Stokes wave approaching its limiting form with $2\\pi/3$ radians angle on the crest. A conformal map is used which maps a free fluid surface of Stokes wave into the real line with fluid domain mapped into the lower complex half-plane. The Stokes wave is fully characterized by the complex singularities in the upper complex half-plane. These singularities are addressed by rational (Pad\\'e) interpolation of Stokes wave in the complex plane. Convergence of Pad\\'e approximation to the density of complex poles with the increase of the numerical precision and subsequent increase of the number of approximating poles reveals that the only singu...

  5. Tell President Obama About Coal River Mountain Coal River Mountain and the Heathrow Airport runway remind me how important it is to

    E-Print Network [OSTI]

    Hansen, James E.

    Tell President Obama About Coal River Mountain Coal River Mountain and the Heathrow Airport runway remind me how important it is to keep our eye on the ball. Coal River Mountain is the site of an absurdity. I learned about Coal River Mountain from students at Virginia Tech last fall. They were concerned

  6. PV Cell and Module Calibrations at NREL

    SciTech Connect (OSTI)

    Emery, Keith

    2012-10-22

    NREL has equipment to measure any conceivable cell or module technology. The lack of standards for low concentration modules complicates matters. Spectrally adjustable simulators are critical for more than three junctions. NREL's 10-channel fiber optic simulator has shown that the light can be set for each junction within 1% of what it would be under the reference spectrum for up to a five-junction cell. Uncertainty in module simulators dominated by spatial nonuniformity for calibration labs. Manufacturers can mitigate this error by using matched reference modules instead of cells.

  7. ARM - Evaluation Product - Calibrated KAZR Data

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Comments? WeDatastreamstps DocumentationAtlanticENA Contacts ENA RelatedProductsCalibrated KAZR Data ARM Data

  8. Method and apparatus for calibrating a particle emissions monitor

    DOE Patents [OSTI]

    Flower, William L. (Livermore, CA); Renzi, Ronald F. (Tracy, CA)

    1998-07-07

    The instant invention discloses method and apparatus for calibrating particulate emissions monitors, in particular, and sampling probes, in general, without removing the instrument from the system being monitored. A source of one or more specific metals in aerosol (either solid or liquid) or vapor form is housed in the instrument. The calibration operation is initiated by moving a focusing lens, used to focus a light beam onto an analysis location and collect the output light response, from an operating position to a calibration position such that the focal point of the focusing lens is now within a calibration stream issuing from a calibration source. The output light response from the calibration stream can be compared to that derived from an analysis location in the operating position to more accurately monitor emissions within the emissions flow stream.

  9. Method and apparatus for calibrating a particle emissions monitor

    DOE Patents [OSTI]

    Flower, W.L.; Renzi, R.F.

    1998-07-07

    The invention discloses a method and apparatus for calibrating particulate emissions monitors, in particular, sampling probes, and in general, without removing the instrument from the system being monitored. A source of one or more specific metals in aerosol (either solid or liquid) or vapor form is housed in the instrument. The calibration operation is initiated by moving a focusing lens, used to focus a light beam onto an analysis location and collect the output light response, from an operating position to a calibration position such that the focal point of the focusing lens is now within a calibration stream issuing from a calibration source. The output light response from the calibration stream can be compared to that derived from an analysis location in the operating position to more accurately monitor emissions within the emissions flow stream. 6 figs.

  10. Photometric Calibration of the Swift Ultraviolet/Optical Telescope

    E-Print Network [OSTI]

    Poole, T S; Page, M J; Landsman, W; Holland, S T; Roming, P; Kuin, N P M; Brown, P J; Gronwall, C; Hunsberger, S; Koch, S; Mason, K O; Schady, P; Berk, D Vanden; Blustin, A J; Boyd, P; Broos, P; Carter, M; Chester, M M; Cucchiara, A; Hancock, B; Huckle, H; Immler, S; Ivanushkina, M; Kennedy, T; Marshall, F; Morgan, A; Pandey, S; de Pasquale, M; Smith, P J; Still, M

    2007-01-01

    We present the photometric calibration of the Swift UltraViolet/Optical Telescope (UVOT) which includes: optimum photometric and background apertures, effective area curves, colour transformations, conversion factors for count rates to flux, and the photometric zero points (which are accurate to better than 4 per cent) for each of the seven UVOT broadband filters. The calibration was performed with observations of standard stars and standard star fields that represent a wide range of spectral star types. The calibration results include the position dependent uniformity, and instrument response over the 1600-8000A operational range. Because the UVOT is a photon counting instrument, we also discuss the effect of coincidence loss on the calibration results. We provide practical guidelines for using the calibration in UVOT data analysis. The results presented here supersede previous calibration results.

  11. Photometric Calibration of the Swift Ultraviolet/Optical Telescope

    E-Print Network [OSTI]

    T. S. Poole; A. A. Breeveld; M. J. Page; W. Landsman; S. T. Holland; P. Roming; N. P. M. Kuin; P. J. Brown; C. Gronwall; S. Hunsberger; S. Koch; K. O. Mason; P. Schady; D. Vanden Berk; A. J. Blustin; P. Boyd; P. Broos; M. Carter; M. M. Chester; A. Cucchiara; B. Hancock; H. Huckle; S. Immler; M. Ivanushkina; T. Kennedy; F. Marshall; A. Morgan; S. Pandey; M. de Pasquale; P. J. Smith; M. Still

    2007-11-09

    We present the photometric calibration of the Swift UltraViolet/Optical Telescope (UVOT) which includes: optimum photometric and background apertures, effective area curves, colour transformations, conversion factors for count rates to flux, and the photometric zero points (which are accurate to better than 4 per cent) for each of the seven UVOT broadband filters. The calibration was performed with observations of standard stars and standard star fields that represent a wide range of spectral star types. The calibration results include the position dependent uniformity, and instrument response over the 1600-8000A operational range. Because the UVOT is a photon counting instrument, we also discuss the effect of coincidence loss on the calibration results. We provide practical guidelines for using the calibration in UVOT data analysis. The results presented here supersede previous calibration results.

  12. Method for in-situ calibration of electrophoretic analysis systems

    DOE Patents [OSTI]

    Liu, Changsheng (State College, PA); Zhao, Hequan (State College, PA)

    2005-05-08

    An electrophoretic system having a plurality of separation lanes is provided with an automatic calibration feature in which each lane is separately calibrated. For each lane, the calibration coefficients map a spectrum of received channel intensities onto values reflective of the relative likelihood of each of a plurality of dyes being present. Individual peaks, reflective of the influence of a single dye, are isolated from among the various sets of detected light intensity spectra, and these can be used to both detect the number of dye components present, and also to establish exemplary vectors for the calibration coefficients which may then be clustered and further processed to arrive at a calibration matrix for the system. The system of the present invention thus permits one to use different dye sets to tag DNA nucleotides in samples which migrate in separate lanes, and also allows for in-situ calibration with new, previously unused dye sets.

  13. Calibrating Accelerometers Using an Electromagnetic Launcher

    SciTech Connect (OSTI)

    Erik Timpson

    2012-05-13

    A Pulse Forming Network (PFN), Helical Electromagnetic Launcher (HEML), Command Module (CM), and Calibration Table (CT) were built and evaluated for the combined ability to calibrate an accelerometer. The PFN has a maximum stored energy of 19.25 kJ bank and is fired by a silicon controlled rectifier (SCR), with appropriate safety precautions. The HEML is constructed out of G-10 fiberglass and is designed to accelerate 600 grams to 10 meters per second. The CM is microcontroller based running Arduino Software. The CM has a keypad input and 7 segment outputs of the bank voltage and desired voltage. After entering a desired bank voltage, the CM controls the charge of the PFN. When the two voltages are equal it allows the fire button to send a pulse to the SCR to fire the PFN and in turn, the HEML. The HEML projectile's tip hits a target that is held by the CT. The CT consists of a table to hold the PFN and HEML, a vacuum chuck, air bearing, velocity meter and catch pot. The Target is held with the vacuum chuck awaiting impact. After impact, the air bearing allows the target to fall freely for the velocity meter to get an accurate reading. A known acceleration is determined from the known change in velocity of the target. Thus, if an accelerometer was attached to the target, the measured value can be compared to the known value.

  14. Calibration curves for some standard Gap Tests

    SciTech Connect (OSTI)

    Bowman, A.L.; Sommer, S.C.

    1989-01-01

    The relative shock sensitivities of explosive compositions are commonly assessed using a family of experiments that can be described by the generic term ''Gap Test.'' Gap tests include a donor charge, a test sample, and a spacer, or gap, between two explosives charges. The donor charge, gap material, and test dimensions are held constant within each different version of the gap test. The thickness of the gap is then varied to find the value at which 50% of the test samples will detonate. The gap tests measure the ease with a high-order detonation can be established in the test explosive, or the ''detonability,'' of the explosive. Test results are best reported in terms of the gap thickness at the 50% point. It is also useful to define the shock pressure transmitted into the test sample at the detonation threshold. This requires calibrating the gap test in terms of shock pressure in the gap as a function of the gap thickness. It also requires a knowledge of the shock Hugoniot of the sample explosive. We used the 2DE reactive hydrodynamic code with Forest Fire burn rates for the donor explosives to calculate calibration curves for several gap tests. The model calculations give pressure and particle velocity on the centerline of the experimental set-up and provide information about the curvature and pulse width of the shock wave. 10 refs., 1 fig.

  15. Development of a Dynamic DOE Calibration Model | Department of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    model was developed. The model can be applied for calibration and control system optimization. p-22anderson.pdf More Documents & Publications Reducing the Particulate Emission...

  16. AV Presentation -Dowell Hall 206 Apple iPads are being used to control the switching of AV Signals between Sources to Displays.

    E-Print Network [OSTI]

    Minnesota, University of

    to stay powered on, but may go into sleep mode. Press the "Home" button to wake up, then finger slide approximately 1 minute to completely shut down, (Flashing Orange light on Prj). Wait for "Solid Orange" Light = Projector is now powered OFF. Press "Display 1 or 2" on iPad,,, Flashing Green Light on Prj

  17. AV Presentation -Dowell Hall 225 Apple iPads are being used to control the switching of AV Signals between Sources to Displays.

    E-Print Network [OSTI]

    Minnesota, University of

    to stay powered on, but may go into sleep mode. Press the "Home" button to wake up, then finger slide approximately 1 minute to completely shut down, (Flashing Orange light on Prj). Wait for "Solid Orange" Light = Projector is now powered OFF. Press "Display 1 or 2" on iPad,,, Flashing Green Light on Prj

  18. Fan and Pad Greenhouse Evaporative Cooling Systems1 R. A. Bucklin, J. D. Leary, D. B. McConnell, and E. G. Wilkerson2

    E-Print Network [OSTI]

    Hill, Jeffrey E.

    CIR1135 Fan and Pad Greenhouse Evaporative Cooling Systems1 R. A. Bucklin, J. D. Leary, D. B. Mc systems. Such high temperatures reduce crop quality and worker productivity. Evaporative cooling temperatures are important when dealing with evaporative cooling systems ­ dry bulb temperature and wet bulb

  19. NRAO's VLBA data calibration pipeline Lorant O. Sjouwerman, Amy J. Mioduszewski, Eric W. Greisen

    E-Print Network [OSTI]

    Sjouwerman, Loránt

    NRAO's VLBA data calibration pipeline Lorant O. Sjouwerman, Amy J. Mioduszewski, Eric W. Greisen VLBA data calibration pipeline is a 'runfile' which executes in AIPS using the VLBAUTIL procedures. The VLBA data calibration pipeline applies basic calibrations to the data and, to evaluate the calibration

  20. COS Calibration Requirements & Procedures Date: March 17, 2002

    E-Print Network [OSTI]

    Colorado at Boulder, University of

    COS Calibration Requirements & Procedures Date: March 17, 2002 Document Number: COS-01 Wilkinson, COS Instrument Scientist Date Reviewed By: Dennis Ebbets 2-15-01 Dr. Dennis Ebbets, COS Calibration Scientist, BASD Date Reviewed By: Jon A. Morse 2-1-01 Dr. Jon Morse, COS Project Scientist Date

  1. COS Calibration Requirements & Procedures Date: May 20, 2002

    E-Print Network [OSTI]

    Colorado at Boulder, University of

    COS Calibration Requirements & Procedures Date: May 20, 2002 Document Number: COS-01-0003 Revision, COS Instrument Scientist Date Reviewed By: Dennis Ebbets 2-15-01 Dr. Dennis Ebbets, COS Calibration Scientist, BASD Date Reviewed By: Jon A. Morse 2-1-01 Dr. Jon Morse, COS Project Scientist Date Approved By

  2. COS Prelaunch Calibration Data Date: March 13, 2008

    E-Print Network [OSTI]

    Colorado at Boulder, University of

    COS Prelaunch Calibration Data Date: March 13, 2008 Document Number: COS-01-0008 Revision: Revision A Contract No.: NAS5-98043 CDRL No.: AV-04 Prepared By: Dr. Erik Wilkinson 5/14/04 Dr. E. Wilkinson, COS Project Scientist, CU Date Reviewed By: Dr. Dennis Ebbets 5/14/04 Dr. D. Ebbets, COS Calibration Scientist

  3. Brookhaven National Laboratory meteorological services instrument calibration plan and procedures

    SciTech Connect (OSTI)

    Heiser .

    2013-02-16

    This document describes the Meteorological Services (Met Services) Calibration and Maintenance Schedule and Procedures, The purpose is to establish the frequency and mechanism for the calibration and maintenance of the network of meteorological instrumentation operated by Met Services. The goal is to maintain the network in a manner that will result in accurate, precise and reliable readings from the instrumentation.

  4. Calibrating Speed-Density Functions for ff SMesoscopic Traffic Simulation

    E-Print Network [OSTI]

    Bertini, Robert L.

    -line) · DynaMIT: Mesoscopic model to be calibrated - Disaggregate (microscopic) demand - Aggregate (macroscopic (2002), Balakrishna et al. (2007) · On-line - Adjustments in response to real-time data · Doan et al-level supply calibration with counts D d R f- Demand same as Ref #12;Case Study II: Lower Westchester County

  5. Eddy Currents and Magnetic Calibrations in LDX using a

    E-Print Network [OSTI]

    Eddy Currents and Magnetic Calibrations in LDX using a "Copper Plasma" D.P. Boyle, PPPL M.E. Mauel Calibrate magnetic diagnostics positions and gains Find eddy current decay times Copper Plasma Operation electronically Would be better to measure positions and total gains magnetically #12;Goal: Eddy Currents Magnetic

  6. VICARIOUS CALIBRATION OF GLOBAL PRECIPITATION MEASUREMENT MICROWAVE RADIOMETERS1

    E-Print Network [OSTI]

    Ruf, Christopher

    VICARIOUS CALIBRATION OF GLOBAL PRECIPITATION MEASUREMENT MICROWAVE RADIOMETERS1 Darren Mc of the TMI, WindSat, SSM/I F13 and SSM/I F14 microwave radiometers using data from the GPM Inter Terms-- Microwave radiometry, Calibration 1. INTRODUCTION The primary goal of NASA's Global

  7. CU-LASP Test Facilities ! and Instrument Calibration Capabilities"

    E-Print Network [OSTI]

    Mojzsis, Stephen J.

    ­ Computer-controlled monochromator for wavelength selection ­ Deuterium lamp is primary light source ­ 2°C #12;Calibration and Test Equipment 3 (CTE 3) · Characterization of detectors and detector modules;Total Solar Irradiance Radiometer Facility (TRF) · Total Solar Irradiance (TSI) instrument calibrations

  8. Fast Switching Phase Calibration: Effectiveness at Mauna Kea and Chajnantor

    E-Print Network [OSTI]

    Groppi, Christopher

    Fast Switching Phase Calibration: Effectiveness at Mauna Kea and Chajnantor M.A. Holdaway, Simon J We present estimates of how well fast switching phase calibration would perform at the Chajnantor, Chile, and Mauna Kea VLBA sites. Fast switching at Chajnantor would achieve better than 30 ffi r. m. s

  9. Absolute Calibration of a Large-diameter Light Source

    E-Print Network [OSTI]

    Brack, J T; Dorofeev, A; Gookin, B; Harton, J L; Petrov, Y; Rovero, A C

    2013-01-01

    A method of absolute calibration for large aperture optical systems is presented, using the example of the Pierre Auger Observatory fluorescence detectors. A 2.5 m diameter light source illuminated by an ultra--violet light emitting diode is calibrated with an overall uncertainty of 2.1 % at a wavelength of 365 nm.

  10. Automatic calibration of LDA measurement volume size Mark Saffman

    E-Print Network [OSTI]

    Saffman, Mark

    Automatic calibration of LDA measurement volume size Mark Saffman The problem of particle number the instrument measurement cross section are given. An automatic calibration method for determining unknown are difficult and have rarely been reported inthe liter- ature. A new method of automatically determining

  11. In Situ Jet Energy Calibration In Atlas Based On

    E-Print Network [OSTI]

    Hupkes, Hermen Jan

    In Situ Jet Energy Calibration In Atlas Based On Z+Jet Events By Hermen Jan Hupkes 252 Ge; IN SITU JET ENERGY CALIBRATION IN ATLAS BASED ON Z+JET EVENTS Hermen Jan Hupkes Mathematisch Instituut #12; #12; Contents 1 Introduction 1 2 The Atlas Detector 7 3 Jet Measurements in Atlas 11 3

  12. In Situ Jet Energy Calibration In Atlas Based On

    E-Print Network [OSTI]

    Hupkes, Hermen Jan

    In Situ Jet Energy Calibration In Atlas Based On Z+Jet Events By Hermen Jan Hupkes 252 Ge SITU JET ENERGY CALIBRATION IN ATLAS BASED ON Z+JET EVENTS Hermen Jan Hupkes Mathematisch Instituut #12;#12;Contents 1 Introduction 1 2 The Atlas Detector 7 3 Jet Measurements in Atlas 11 3

  13. Travel and Accommodations: Students will make their own travel arrangement and should plan flights to arrive on May 9th and leave on June 3rd.Students can take a taxi to the 92nd St. Y from the airport.The closest airport in LaGuardia.We will live and mee

    E-Print Network [OSTI]

    Bordenstein, Seth

    to arrive on May 9th and leave on June 3rd.Students can take a taxi to the 92nd St. Y from the airport for an optional fee. a contemporary art blitz - May 9th thru June 3rd, 2011 Course Description: This course week. Program Dates: May 9th ­ June 3rd 2011 Daily schedule to be announced. Contact: diane

  14. Public health assessment for St. Louis Airport, Hazelwood Interim Storage/Futura Coatings Company, St. Louis, St. Louis County, Missouri, Region 7. Cerclis No. MOD980633176. Preliminary report

    SciTech Connect (OSTI)

    Not Available

    1994-01-20

    The St. Louis Airport/Hazelwood Iterim Storage/Futura Coatings Company, a National Priorities List site, is in St. Louis County, Missouri. From 1946 to 1973, the site was used to store radioactive materials resulting from uranium processing. High levels of uranium, thorium, radium, and radon were detected in soil, groundwater, and air. The site is still being used to store radioactive materials. The Agency for Toxic Substances and Disease Registry considers the St. Louis Airport site to be an indeterminate public health hazard. Although there are emissions of radon and the presence of thorium in on-site air and off-site soils and the emission of radiation resulting from the presence of these materials is not currently considered a health hazard. At present conditions, the concentration of radon off-site is indistinguishable from background levels. However, in the past, these contaminants may have been present at levels of health concern.

  15. A Calibrated Computer Model for the Thermal Simulation of Courtyard Microclimates 

    E-Print Network [OSTI]

    Bagneid, A.; Haberl, J.

    2006-01-01

    This paper describes a calibrated stand-alone courtyard microclimate model. This model is considered to be the fIrst calibrated computer program for the simulation of courtyard microclimates. In order to accomplish this a calibrated simplif...

  16. Automatic Calibration of Freeway Models with Model-Based Fault Detection

    E-Print Network [OSTI]

    Dervisoglu, Gunes

    2012-01-01

    3 Automatic Freeway Model Calibration Procedure 3.1 FreewayR. Horowitz, and P. Varaiya. Automatic calibration of theAutomatic Calibration of Freeway Models with Model-Based

  17. Extending Sensor Calibration Intervals in Nuclear Power Plants

    SciTech Connect (OSTI)

    Coble, Jamie B.; Meyer, Ryan M.; Ramuhalli, Pradeep; Bond, Leonard J.; Shumaker, Brent; Hashemian, Hash

    2012-11-15

    Currently in the USA, sensor recalibration is required at every refueling outage, and it has emerged as a critical path item for shortening outage duration. International application of calibration monitoring, such as at the Sizewell B plant in UK, has shown that sensors may operate for eight years, or longer, within calibration tolerances. Online monitoring can be employed to identify those sensors which require calibration, allowing for calibration of only those sensors which need it. The US NRC accepted the general concept of online monitoring for sensor calibration monitoring in 2000, but no plants have been granted the necessary license amendment to apply it. This project addresses key issues in advanced recalibration methodologies and provides the science base to enable adoption of best practices for applying online monitoring, resulting in a public domain standardized methodology for sensor calibration interval extension. Research to develop this methodology will focus on three key areas: (1) quantification of uncertainty in modeling techniques used for calibration monitoring, with a particular focus on non-redundant sensor models; (2) accurate determination of acceptance criteria and quantification of the effect of acceptance criteria variability on system performance; and (3) the use of virtual sensor estimates to replace identified faulty sensors to extend operation to the next convenient maintenance opportunity.

  18. MESERAN Calibration for Low Level Organic Residues

    SciTech Connect (OSTI)

    Benkovich, M.G.

    2004-04-08

    Precision cleaning studies done at Honeywell Federal Manufacturing & Technologies (FM&T), the Kansas City Plant (KCP), and at other locations within the Department of Energy (DOE) Weapons complex over the last 30 years have depended upon results from MESERAN Evaporative Rate Analysis for detecting low levels of organic contamination. The characterization of the surface being analyzed is carried out by depositing a Carbon-14 tagged radiochemical onto the test surface and monitoring the rate at which the radiochemical disappears from the surface with a Geiger-Mueller counter. In the past, the total number of counts over a 2-minute span have been used to judge whether a surface is contaminated or not and semi-quantitatively to what extent. This technique is very sensitive but has not enjoyed the broad acceptance of a purely quantitative analysis. The work on this project developed calibrations of various organic contaminants typically encountered in KCP operations. In addition, a new analysis method was developed to enhance the ability of MESERAN Analyzers to detect organic contamination and yield quantitative data in the microgram and nanogram levels.

  19. Polarization imaging apparatus with auto-calibration

    DOE Patents [OSTI]

    Zou, Yingyin Kevin; Zhao, Hongzhi; Chen, Qiushui

    2013-08-20

    A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set, a first variable phase retarder (VPR) with its optical axis aligned 22.5.degree., a second variable phase retarder with its optical axis aligned 45.degree., a linear polarizer, a imaging sensor for sensing the intensity images of the sample, a controller and a computer. Two variable phase retarders were controlled independently by a computer through a controller unit which generates a sequential of voltages to control the phase retardations of the first and second variable phase retarders. A auto-calibration procedure was incorporated into the polarization imaging apparatus to correct the misalignment of first and second VPRs, as well as the half-wave voltage of the VPRs. A set of four intensity images, I.sub.0, I.sub.1, I.sub.2 and I.sub.3 of the sample were captured by imaging sensor when the phase retardations of VPRs were set at (0,0), (.pi.,0), (.pi.,.pi.) and (.pi./2,.pi.), respectively. Then four Stokes components of a Stokes image, S.sub.0, S.sub.1, S.sub.2 and S.sub.3 were calculated using the four intensity images.

  20. SSC and G-2 calorimeter and optical calibration. Progress report, September 15, 1992--September 14, 1993

    SciTech Connect (OSTI)

    Winn, D.R.

    1993-11-01

    This report discusses: Task A: G-2 Photomultiplier & Calibration Systems (BNL E821) and Task B: Optical Calorimeter R&D & Calibration for High Rates & Colliders.

  1. Stochastic Modeling of Overtime Occupancy and Its Application in Building Energy Simulation and Calibration

    E-Print Network [OSTI]

    Sun, Kaiyu

    2014-01-01

    Calibrated building energy simulation and its application inparameters in energy simulation of office buildings. EnergyApplication in Building Energy Simulation and Calibration

  2. Improvements in the Blackbody Calibration of Pyrgeometers (Presentation)

    SciTech Connect (OSTI)

    Reda, I.; Grobner, J.; Stoffel, T.; Myers, D.; Forgan, B.

    2008-03-01

    Pyrgeometers are used to measure the atmospheric longwave irradiance throughout the ARM program sites. Previous calibrations of pyrgeometers using ARM/Eppley/NREL blackbody were consistent, but introduced a difference in the historical clear sky measured irradiance. This difference was believed to be in the order of 12 W/m2. In this poster we show the improvements to the blackbody and calibration methodology by comparing our results to the results of a group of pyrgeometers that were recently calibrated against the World Infrared Standard Group, in the World Radiation Center, Davos/Switzerland.

  3. CALIBRATION OF SEISMIC ATTRIBUTES FOR RESERVOIR CHARACTERIZATION

    SciTech Connect (OSTI)

    Wayne D. Pennington; Horacio Acevedo; Aaron Green; Joshua Haataja; Shawn Len; Anastasia Minaeva; Deyi Xie

    2002-10-01

    The project, ''Calibration of Seismic Attributes for Reservoir Calibration,'' is now complete. Our original proposed scope of work included detailed analysis of seismic and other data from two to three hydrocarbon fields; we have analyzed data from four fields at this level of detail, two additional fields with less detail, and one other 2D seismic line used for experimentation. We also included time-lapse seismic data with ocean-bottom cable recordings in addition to the originally proposed static field data. A large number of publications and presentations have resulted from this work, including several that are in final stages of preparation or printing; one of these is a chapter on ''Reservoir Geophysics'' for the new Petroleum Engineering Handbook from the Society of Petroleum Engineers. Major results from this project include a new approach to evaluating seismic attributes in time-lapse monitoring studies, evaluation of pitfalls in the use of point-based measurements and facies classifications, novel applications of inversion results, improved methods of tying seismic data to the wellbore, and a comparison of methods used to detect pressure compartments. Some of the data sets used are in the public domain, allowing other investigators to test our techniques or to improve upon them using the same data. From the public-domain Stratton data set we have demonstrated that an apparent correlation between attributes derived along ''phantom'' horizons are artifacts of isopach changes; only if the interpreter understands that the interpretation is based on this correlation with bed thickening or thinning, can reliable interpretations of channel horizons and facies be made. From the public-domain Boonsville data set we developed techniques to use conventional seismic attributes, including seismic facies generated under various neural network procedures, to subdivide regional facies determined from logs into productive and non-productive subfacies, and we developed a method involving cross-correlation of seismic waveforms to provide a reliable map of the various facies present in the area. The Wamsutter data set led to the use of unconventional attributes including lateral incoherence and horizon-dependent impedance variations to indicate regions of former sand bars and current high pressure, respectively, and to evaluation of various upscaling routines. The Teal South data set has provided a surprising set of results, leading us to develop a pressure-dependent velocity relationship and to conclude that nearby reservoirs are undergoing a pressure drop in response to the production of the main reservoir, implying that oil is being lost through their spill points, never to be produced. Additional results were found using the public-domain Waha and Woresham-Bayer data set, and some tests of technologies were made using 2D seismic lines from Michigan and the western Pacific ocean.

  4. Calibrations of alpha Cen A & B

    E-Print Network [OSTI]

    P. Morel; J. Provost; Y. Lebreton; F. Thevenin; G. Berthomieu

    2000-10-10

    Detailed evolutionary models of the visual binary alpha Centauri, including pre main-sequence evolution, have been performed using the masses recently determined by Pourbaix et al. (1999). Models have been constructed using the CEFF equation of state, OPAL opacities, NACRE thermonuclear reaction rates and microscopic diffusion. A chi^2-minimization is performed to derive the most reliable set of modeling parameters wp={t_alpha Cen, Yi, [Fe/H]i, alpha A, alpha B}, where t alpha Cen is the age of the system, Yi the initial helium content, [Fe/H]i the initial metallicity and, alpha A and alpha B the convection parameters of the two components. Using the basic Bohm-Vitense (1958) mixing-length theory of convection, we derive wp BV={2710 Myr, 0.284,0.257, 1.53, 1.57}. We obtain a noticeably smaller age than estimated previously, in agreement with Pourbaix et al. (1999), mainly because of the larger masses. If convective core overshoot is considered we get wp ov={3530 Myr, 0.279,0.264,1.64,1.66}. The use of Canuto & Mazitelli (1991, 1992) convection theory leads to the set wp CM={4086 Myr, 0.271, 0.264, 0.964, 0.986}. Using the observational constraints adopted by Guenther & Demarque (2000), and the basic mixing-length theory, we obtain wp GD={5640 Myr, 0.300, 0.296, 1.86, 1.97} and surface lithium depletions close to their observed values. A seismological analysis of our calibrated models has been performed. The determination of large and small spacings between the frequencies of acoustic oscillations from seismic observations would help to discriminate between the models of alpha Cen computed with different masses and to confirm or rules out the new determination of masses.

  5. Setting up @MyHunter (Office365) -Apple iPhone, iPad, or iPod touch: 1. Tap Settings > Mail, Contacts, Calendars > Add Account.

    E-Print Network [OSTI]

    Qiu, Weigang

    Setting up @MyHunter (Office365) - Apple iPhone, iPad, or iPod touch: 1. Tap Settings > Mail.cuny.edu). 4. Tap Next on the upper-right corner of the screen. Your Apple device will try to find the settings it needs to set up your account. 5. If your Apple device can't find your settings automatically, you

  6. Calibration of a Hopkinson Bar with a Transfer Standard

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Bateman, Vesta I.; Leisher, William B.; Brown, Fred A.; Davie, Neil T.

    1993-01-01

    A program requirement for field test temperatures that are beyond the test accelerometer operational limits of ?30°?F and +150°?F required the calibration of accelerometers at high shock levels and at the temperature extremes of ?50°?F and +160°?F. The purposes of these calibrations were to insure that the accelerometers operated at the field test temperatures and to provide an accelerometer sensitivity at each test temperature. Because there is no National Institute of Standards and Technology traceable calibration capability at shock levels of 5,000–15,000 g for the temperature extremes of ?50°?F and +160°?F, a method for calibrating and certifying the Hopkinson barmore »with a transfer standard was developed. Time domain and frequency domain results are given that characterize the Hopkinson bar. The National Institute of Standards and Technology traceable accuracy for the standard accelerometer in shock is ±5%. The Hopkinson bar has been certified with an uncertainty of 6%.« less

  7. Calibration Analysis Software for the ATLAS Pixel Detector

    E-Print Network [OSTI]

    Stramaglia, Maria Elena; The ATLAS collaboration

    2015-01-01

    The calibration of the ATLAS Pixel detector at LHC fulfils two main purposes: to tune the front-end configuration parameters for establishing the best operational settings and to measure the tuning performance through a subset of scans. An analysis framework has been set up in order to take actions on the detector given the outcome of a calibration scan (e.g. to create a mask for disabling noisy pixels). The software framework to control all aspects of the Pixel detector scans and analyses is called Calibration Console. The introduction of a new layer, equipped with new Front End-I4 Chips, required an update the Console architecture. It now handles scans and scans analyses applied together to chips with different characteristics. An overview of the newly developed Calibration Analysis Software will be presented, together with some preliminary result.

  8. Calibrated Probabilistic Mesoscale Weather Field Forecasting: The Geostatistical Output Perturbation

    E-Print Network [OSTI]

    Raftery, Adrian

    Calibrated Probabilistic Mesoscale Weather Field Forecasting: The Geostatistical Output. This is typically not feasible for mesoscale weather prediction carried out locally by organizations without by simulating realizations of the geostatistical model. The method is applied to 48-hour mesoscale forecasts

  9. MICROWAVE RADIOMETER INTER-CALIBRATION: ALGORITHM DEVELOPMENT AND APPLICATION

    E-Print Network [OSTI]

    Ruf, Christopher

    MICROWAVE RADIOMETER INTER-CALIBRATION: ALGORITHM DEVELOPMENT AND APPLICATION by Rachael Ann 1.2.2 Microwave Remote Sensing............................................................................... 8 1.2.4 Spaceborne Microwave Radiometers: Roadmap to TRMM and GPM ...... 10 1.2.5 The Tropical

  10. Automatic calibration of modulated fractional-N frequency synthesizers

    E-Print Network [OSTI]

    McMahill, Dan

    2001-01-01

    The focus of this research has been the development of a low power, radio frequency transmitter architecture. Specifically, a technique for in service automatic calibration of a modulated phase locked loop (PLL) frequency ...

  11. Method and apparatus for calibrating a linear variable differential transformer

    DOE Patents [OSTI]

    Pokrywka, Robert J. (North Huntingdon, PA)

    2005-01-18

    A calibration apparatus for calibrating a linear variable differential transformer (LVDT) having an armature positioned in au LVDT armature orifice, and the armature able to move along an axis of movement. The calibration apparatus includes a heating mechanism with an internal chamber, a temperature measuring mechanism for measuring the temperature of the LVDT, a fixture mechanism with an internal chamber for at least partially accepting the LVDT and for securing the LVDT within the heating mechanism internal chamber, a moving mechanism for moving the armature, a position measurement mechanism for measuring the position of the armature, and an output voltage measurement mechanism. A method for calibrating an LVDT, including the steps of: powering the LVDT; heating the LVDT to a desired temperature; measuring the position of the armature with respect to the armature orifice; and measuring the output voltage of the LVDT.

  12. Advanced DOE-2 Calibration Procedures: A Technical Reference Manual 

    E-Print Network [OSTI]

    Bou-Saada, T. E.

    1994-01-01

    Center. Appendix A contains the data processing routines. Appendix B contains the final calibrated input file. Appendix C contains processing and column merging routines. Appendix D contains the SAS graphical routines. Appendix E contains a solar...

  13. Gas characterization system operation, maintenance, and calibration plan

    SciTech Connect (OSTI)

    Tate, D.D.

    1996-03-04

    This document details the responsibilities and requirements for operation, maintenance, and calibration of the Gas Characterization Systems (GCS) analytical instrumentation. It further, defines the division of responsibility between the Characterization Monitoring Development organization and Tank Farms Operations.

  14. Calibration of accelerometers on the 5000 g centrifuge

    SciTech Connect (OSTI)

    Rebarchik, F.N.

    1992-05-01

    This memorandum is a synopsis of the description and operation of the equipment used and the events occurring during the calibration of an accelerometer on the 5000 g centrifuge.

  15. Calibration of accelerometers on the 1000 g centrifuge

    SciTech Connect (OSTI)

    Rebarchik, F.N.

    1991-04-01

    This memorandum is a synopsis of the description and operation of the equipment used, and the events occurring during the calibration of an accelerometer on the 1000 G centrifuge. 2 refs., 1 tab.

  16. Laser calibration system for the CERES Time Projection Chamber

    E-Print Network [OSTI]

    Dariusz Miskowiec; Peter Braun-Munzinger

    2008-02-15

    A Nd:YAG laser was used to simulate charged particle tracks at known positions in the CERES Time Projection Chamber at the CERN SPS. The system was primarily developed to study the response of the readout electronics and to calibrate the electron drift velocity. Further applications were the determination of the gating grid transparency, the chamber position calibration, and long-term monitoring of drift properties of the gas in the detector.

  17. Gearbox Reliability Collaborative High-Speed Shaft Calibration

    SciTech Connect (OSTI)

    Keller, J.; McNiff, B.

    2014-09-01

    Instrumentation has been added to the high-speed shaft, pinion, and tapered roller bearing pair of the Gearbox Reliability Collaborative gearbox to measure loads and temperatures. The new shaft bending moment and torque instrumentation was calibrated and the purpose of this document is to describe this calibration process and results, such that the raw shaft bending and torque signals can be converted to the proper engineering units and coordinate system reference for comparison to design loads and simulation model predictions.

  18. Hydrologic calibration of paired watersheds using a MOSUM approach

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Ssegane, H.; Amatya, D. M.; Muwamba, A.; Chescheir, G. M.; Appelboom, T.; Tollner, E. W.; Nettles, J. E.; Youssef, M. A.; Birgand, F.; Skaggs, R. W.

    2015-01-09

    Paired watershed studies have historically been used to quantify hydrologic effects of land use and management practices by concurrently monitoring two neighboring watersheds (a control and a treatment) during the calibration (pre-treatment) and post-treatment periods. This study characterizes seasonal water table and flow response to rainfall during the calibration period and tests a change detection technique of moving sums of recursive residuals (MOSUM) to select calibration periods for each control-treatment watershed pair when the regression coefficients for daily water table elevation (WTE) were most stable to reduce regression model uncertainty. The control and treatment watersheds included 1–3 year intensively managedmore »loblolly pine (Pinus taeda L.) with natural understory, same age loblolly pine intercropped with switchgrass (Panicum virgatum), 14–15 year thinned loblolly pine with natural understory (control), and switchgrass only. Although monitoring during the calibration period spanned 2009 to 2012, silvicultural operational practices that occurred during this period such as harvesting of existing stand and site preparation for pine and switchgrass establishment may have acted as external factors, potentially shifting hydrologic calibration relationships between control and treatment watersheds. Results indicated that MOSUM was able to detect significant changes in regression parameters for WTE due to silvicultural operations. This approach also minimized uncertainty of calibration relationships which could otherwise mask marginal treatment effects. All calibration relationships developed using this MOSUM method were quantifiable, strong, and consistent with Nash–Sutcliffe Efficiency (NSE) greater than 0.97 for WTE and NSE greater than 0.92 for daily flow, indicating its applicability for choosing calibration periods of paired watershed studies.« less

  19. Abstract--A measurement calibration method is described in this paper. The proposed method identifies calibration models

    E-Print Network [OSTI]

    in state estima- tion. Measurement calibration at the substation is a labor intensive and costly process that is described in [2]-[3] is executed at individual substations by taking advantage of the redundancy provided

  20. Be production-rate calibration for the Arctic NICOLA S E. YOUNG,1,2

    E-Print Network [OSTI]

    Briner, Jason P.

    A 10 Be production-rate calibration for the Arctic NICOLA´ S E. YOUNG,1,2 * JOERG M. SCHAEFER,1 2013; Accepted 18 April 2013 ABSTRACT: We present a Baffin Bay 10 Be production-rate calibration published 10 Be calibration datasets to develop an Arctic 10 Be production rate. Our calibration comprises

  1. Geochemical information for sites contaminated with low-level radioactive wastes: II. St. Louis Airport Storage Site

    SciTech Connect (OSTI)

    Seeley, F.G.; Kelmers, A.D.

    1985-01-01

    The St. Louis Airport Storage Site (SLASS) became radioactively contaminated as a result of wastes that were being stored from operations to recover uranium from pitchblende ores in the 1940s and 1950s. The US Department of Energy is considering various remedial action options for the SLASS under the Formerly Utilized Site Remedial Action Program (FUSRAP). This report describes the results of geochemical investigations, carried out to support the FUSRAP activities and to aid in quantifying various remedial action options. Soil and groundwater samples from the site were characterized, and sorption ratios for uranium and radium and apparent concentration limit values for uranium were measured in soil/groundwater systems by batch contact methodology. The uranium and radium concentrations in soil samples were significantly above background near the old contaminated surface horizon (now at the 0.3/sup -/ to 0.9/sup -/m depth); the maximum values were 1566 ..mu..g/g and 101 pCi/g, respectively. Below about the 6/sup -/m depth, the concentrations appeared to be typical of those naturally present in soils of this area (3.8 +- 1.2 ..mu..g/g and 3.1 +- 0.6 pCi/g). Uranium sorption ratios showed stratigraphic trends but were generally moderate to high (100 to 1000 L/kg). The sorption isotherm suggested an apparent uranium concentration limit of about 200 mg/L. This relatively high solubility can probably be correlated with the carbonate content of the soil/groundwater systems. The lower sorption ratio values obtained from the sorption isotherm may have resulted from changes in the experimental procedure or the groundwater used. The SLASS appears to exhibit generally favorable behavior for the retardation of uranium solubilized from waste in the site. Parametric tests were conducted to estimate the sensitivity of uranium sorption and solubility to the pH and carbonate content of the system.

  2. Calibration of Seismic Attributes for Reservoir Characterization

    SciTech Connect (OSTI)

    Wayne D. Pennington

    2002-09-29

    The project, "Calibration of Seismic Attributes for Reservoir Characterization," is now complete. Our original proposed scope of work included detailed analysis of seismic and other data from two to three hydrocarbon fields; we have analyzed data from four fields at this level of detail, two additional fields with less detail, and one other 2D seismic line used for experimentation. We also included time-lapse seismic data with ocean-bottom cable recordings in addition to the originally proposed static field data. A large number of publications and presentations have resulted from this work, inlcuding several that are in final stages of preparation or printing; one of these is a chapter on "Reservoir Geophysics" for the new Petroleum Engineering Handbook from the Society of Petroleum Engineers. Major results from this project include a new approach to evaluating seismic attributes in time-lapse monitoring studies, evaluation of pitfalls in the use of point-based measurements and facies classifications, novel applications of inversion results, improved methods of tying seismic data to the wellbore, and a comparison of methods used to detect pressure compartments. Some of the data sets used are in the public domain, allowing other investigators to test our techniques or to improve upon them using the same data. From the public-domain Stratton data set we have demonstrated that an apparent correlation between attributes derived along 'phantom' horizons are artifacts of isopach changes; only if the interpreter understands that the interpretation is based on this correlation with bed thickening or thinning, can reliable interpretations of channel horizons and facies be made. From the public-domain Boonsville data set we developed techniques to use conventional seismic attributes, including seismic facies generated under various neural network procedures, to subdivide regional facies determined from logs into productive and non-productive subfacies, and we developed a method involving cross-correlation of seismic waveforms to provide a reliable map of the various facies present in the area. The Wamsutter data set led to the use of unconventional attributes including lateral incoherence and horizon-dependent impedance variations to indicate regions of former sand bars and current high pressure, respectively, and to evaluation of various upscaling routines. The Teal South data set has provided a surprising set of results, leading us to develop a pressure-dependent velocity relationship and to conclude that nearby reservoirs are undergoing a pressure drop in response to the production of the main reservoir, implying that oil is being lost through their spill points, never to be produced. Additional results were found using the public-domain Waha and Woresham-Bayer data set, and some tests of technologies were made using 2D seismic lines from Michigan and the western Pacific ocean.

  3. The DICE calibration project: design, characterization, and first results

    E-Print Network [OSTI]

    Regnault, N; Schahmanèche, K; Guillou, L Le; Antilogus, P; Astier, P; Barrelet, E; Betoule, M; Bongard, S; Cuillandre, J -C; Juramy, C; Pain, R; Rocci, P -F; Tisserand, P; Villa, F

    2015-01-01

    We describe the design, operation, and first results of a photometric calibration project, called DICE (Direct Illumination Calibration Experiment), aiming at achieving precise instrumental calibration of optical telescopes. The heart of DICE is an illumination device composed of 24 narrow-spectrum, high-intensity, light-emitting diodes (LED) chosen to cover the ultraviolet-to-near-infrared spectral range. It implements a point-like source placed at a finite distance from the telescope entrance pupil, yielding a flat field illumination that covers the entire field of view of the imager. The purpose of this system is to perform a lightweight routine monitoring of the imager passbands with a precision better than 5 per-mil on the relative passband normalisations and about 3{\\AA} on the filter cutoff positions. The light source is calibrated on a spectrophotometric bench. As our fundamental metrology standard, we use a photodiode calibrated at NIST. The radiant intensity of each beam is mapped, and spectra are m...

  4. Design, manufacture, and calibration of infrared radiometric blackbody sources

    SciTech Connect (OSTI)

    Byrd, D.A.; Michaud, F.D.; Bender, S.C.

    1996-04-01

    A Radiometric Calibration Station (RCS) is being assembled at the Los Alamos National Laboratories (LANL) which will allow for calibration of sensors with detector arrays having spectral capability from about 0.4-15 {mu}m. The configuration of the LANL RCS. Two blackbody sources have been designed to cover the spectral range from about 3-15 {mu}m, operating at temperatures ranging from about 180-350 K within a vacuum environment. The sources are designed to present a uniform spectral radiance over a large area to the sensor unit under test. The thermal uniformity requirement of the blackbody cavities has been one of the key factors of the design, requiring less than 50 mK variation over the entire blackbody surface to attain effective emissivity values of about 0.999. Once the two units are built and verified to the level of about 100 mK at LANL, they will be sent to the National Institute of Standards and Technology (NIST), where at least a factor of two improvement will be calibrated into the blackbody control system. The physical size of these assemblies will require modifications of the existing NIST Low Background Infrared (LBIR) Facility. LANL has constructed a bolt-on addition to the LBIR facility that will allow calibration of our large aperture sources. Methodology for attaining the two blackbody sources at calibrated levels of performance equivalent to present state of the art will be explained in the following.

  5. Padding with Compressed Air 

    E-Print Network [OSTI]

    Beals, C.

    2004-01-01

    , while the plant air pressure drops 9 psi to 79 psi. Four psi of the pressure drop is due to compressor setpoints, while the remaining fall in pressure is due to the increased airflow through the cleanup equipment and piping. Figure 3... pressure variations. Figure 3, depicts the proper application of dedicated storage with metered recovery. In this arrangement, the metering valve paces the airflow into the dedicated storage and prevents pressure variations from having Tanks Chemical...

  6. Learning from history: Adaptive calibration of 'tilting spine' fiber positioners

    E-Print Network [OSTI]

    Gilbert, James

    2015-01-01

    This paper discusses a new approach for determining the calibration parameters of independently-actuated optical fibers in multi-object astronomical fiber positioning systems. This work comes from the development of a new type of piezoelectric motor intended to enhance the 'tilting spine' fiber positioning technology originally created by the Australian Astronomical Observatory. Testing has shown that the motor's performance can vary depending on the fiber's location within its accessible field, meaning that an individual fiber is difficult calibrate with a one-time routine. Better performance has resulted from constantly updating calibration parameters based on the observed movements of the fiber during normal closed-loop positioning. Over time, location-specific historical data is amassed that can be used to better predict the results of a future fiber movement. This is similar to a technique previously proposed by the Australian Astronomical Observatory, but with the addition of location-specific learning....

  7. Universal calculation formula and calibration method in Fourier transform profilometry

    SciTech Connect (OSTI)

    Wen Yongfu; Li Sikun; Cheng Haobo; Su Xianyu; Zhang Qican

    2010-12-01

    We propose a universal calculation formula of Fourier transform profilometry and give a strict theoretical analysis about the phase-height mapping relation. As the request on the experimental setup of the universal calculation formula is unconfined, the projector and the camera can be located arbitrarily to get better fringe information, which makes the operation flexible. The phase-height calibration method under the universal condition is proposed, which can avoid measuring the system parameters directly. It makes the system easy to manipulate and improves the measurement velocity. A computer simulation and experiment are conducted to verify its validity. The calculation formula and calibration method have been applied to measure an object of 22.00 mm maximal height. The relative error of the measurement result is only 0.59%. The experimental results prove that the three-dimensional shape of tested objects can be reconstructed exactly by using the calculation formula and calibration method, and the system has better universality.

  8. System for characterizing semiconductor materials and photovoltaic devices through calibration

    DOE Patents [OSTI]

    Sopori, B.L.; Allen, L.C.; Marshall, C.; Murphy, R.C.; Marshall, T.

    1998-05-26

    A method and apparatus are disclosed for measuring characteristics of a piece of material, typically semiconductor materials including photovoltaic devices. The characteristics may include dislocation defect density, grain boundaries, reflectance, external LBIC, internal LBIC, and minority carrier diffusion length. The apparatus includes a light source, an integrating sphere, and a detector communicating with a computer. The measurement or calculation of the characteristics is calibrated to provide accurate, absolute values. The calibration is performed by substituting a standard sample for the piece of material, the sample having a known quantity of one or more of the relevant characteristics. The quantity measured by the system of the relevant characteristic is compared to the known quantity and a calibration constant is created thereby. 44 figs.

  9. System for characterizing semiconductor materials and photovoltaic devices through calibration

    DOE Patents [OSTI]

    Sopori, Bhushan L. (Denver, CO); Allen, Larry C. (Arvada, CO); Marshall, Craig (Littleton, CO); Murphy, Robert C. (Golden, CO); Marshall, Todd (Littleton, CO)

    1998-01-01

    A method and apparatus for measuring characteristics of a piece of material, typically semiconductor materials including photovoltaic devices. The characteristics may include dislocation defect density, grain boundaries, reflectance, external LBIC, internal LBIC, and minority carrier diffusion length. The apparatus includes a light source, an integrating sphere, and a detector communicating with a computer. The measurement or calculation of the characteristics is calibrated to provide accurate, absolute values. The calibration is performed by substituting a standard sample for the piece of material, the sample having a known quantity of one or more of the relevant characteristics. The quantity measured by the system of the relevant characteristic is compared to the known quantity and a calibration constant is created thereby.

  10. Calorimetric calibration of pyroelectric gamma-radiation detectors

    SciTech Connect (OSTI)

    Strakovskaya, R.Y.; Sras', A.G.

    1985-07-01

    A method has been devised for calibrating a pyroelectric dosimeter, which is based on comparing the readings obtained with it in a gamma-ray beam with the readings of an integral calorimeter under stationary conditions, with the latter previously calibrated from Joule heat. The calorimeter used was in the form of a closed shell, whose overall thermo-emf was independent of the spatial distribution of the heat sources in it, the value being proportional to the integral heat flux through the shell. Measurements were made not only with a quasiisotropic radiation field but also in directed fields. The overall error in calibrating the pyroelectric detectors by this method was less than or equal to plus or minus 10%.

  11. Interval estimation in calibration problems: an alternate approach 

    E-Print Network [OSTI]

    Quaino, Oscar Rodolfo

    1983-01-01

    measurement of the dependent varia- ble. This interval will depend upon the dependent variable and also on the outcome of the calibration experiment. For each unknown a state- ment is made in the sense that it belongs to the interval. Then he searches... is computed as 2 n , 1(yi ? y) Ss n ? 2 and will also be denoted by NSE. (2. 2) In the calibration problem, the classical estimator of x* given an obsezvation y* is y* ? b 0 x* bl Under the normality assumption x" is the NLE of x* (Graybill 1976...

  12. Corrective Action Investigation Plan for Corrective Action Unit 224: Decon Pad and Septic Systems Nevada Test Site, Nevada, Rev. No.: 0, with ROTC 1 and 2

    SciTech Connect (OSTI)

    David A. Strand

    2004-04-01

    This Corrective Action Investigation Plan (CAIP) contains project-specific information including facility descriptions, environmental sample collection objectives, and criteria for conducting site investigation activities at Corrective Action Unit (CAU) 224: Decon Pad and Septic Systems, Nevada Test Site (NTS), Nevada. This CAIP has been developed in accordance with the ''Federal Facility Agreement and Consent Order'' (FFACO) (1996) that was agreed to by the State of Nevada, the U.S. Department of Energy (DOE), and the U.S. Department of Defense (DoD). The NTS is approximately 65 miles (mi) northwest of Las Vegas, Nevada (Figure 1-1). Corrective Action Unit 224 is comprised of the nine Corrective Action Sites (CASs) listed below: 02-04-01, Septic Tank (Buried); 03-05-01, Leachfield; 05-04-01, Septic Tanks (4)/Discharge Area; 06-03-01, Sewage Lagoons (3); 06-05-01, Leachfield; 06-17-04, Decon Pad and Wastewater Catch; 06-23-01, Decon Pad Discharge Piping; 11-04-01, Sewage Lagoon; and 23-05-02, Leachfield. Corrective Action Sites 06-05-01, 06-23-01, and 23-05-02 were identified in the 1991 Reynolds Electrical & Engineering Co., Inc. (REECo) inventory (1991). The remaining sites were identified during review of various historical documents. Additional information will be obtained by conducting a corrective action investigation (CAI) prior to evaluating and selecting a corrective action alternative for each CAS. The CAI will include field inspections, radiological and geological surveys, and sample collection. Data will also be obtained to support investigation-derived waste (IDW) disposal and potential future waste management decisions.

  13. Class 1 Permit Modification Notification Addition of Structures within Technical Area 54, Area G, Pad 11, Dome 375 Los Alamos National Laboratory Hazardous Waste Facility Permit, July 2012

    SciTech Connect (OSTI)

    Vigil-Holterman, Luciana R.; Lechel, Robert A.

    2012-08-31

    The purpose of this letter is to notify the New Mexico Environment Department-Hazardous Waste Bureau (NMED-HWB) of a Class 1 Permit Modification to the Los Alamos National Laboratory (LANL) Hazardous Waste Facility Permit issued to the Department of Energy (DOE) and Los Alamos National Security, LLC (LANS) in November 2010. The modification adds structures to the container storage unit at Technical Area (TA) 54 Area G, Pad 11. Permit Section 3.1(3) requires that changes to the location of a structure that does not manage hazardous waste shall be changed within the Permit as a Class 1 modification without prior approval in accordance with Code of Federal Regulations, Title 40 (40 CFR), {section}270.42(a)(1). Structures have been added within Dome 375 located at TA-54, Area G, Pad 11 that will be used in support of waste management operations within Dome 375 and the modular panel containment structure located within Dome 375, but will not be used as waste management structures. The Class 1 Permit Modification revises Figure 36 in Attachment N, Figures; and Figure G.12-1 in Attachment G.12, Technical Area 54, Area G, Pad 11 Outdoor Container Storage Unit Closure Plan. Descriptions of the structures have also been added to Section A.4.2.9 in Attachment A, TA - Unit Descriptions; and Section 2.0 in Attachment G.12, Technical Area 54, Area G, Pad 11 Outdoor Container Storage Unit Closure Plan. Full description of the permit modification and the necessary changes are included in Enclosure 1. The modification has been prepared in accordance with 40 CFR {section}270.42(a)(l). This package includes this letter and an enclosure containing a description of the permit modification, text edits of the Permit sections, and the revised figures (collectively LA-UR-12-22808). Accordingly, a signed certification page is also enclosed. Three hard copies and one electronic copy of this submittal will be delivered to the NMED-HWB.

  14. COS G130M FUV Grating Calibration And Qualification Plan

    E-Print Network [OSTI]

    Colorado at Boulder, University of

    COS G130M FUV Grating Calibration And Qualification Plan Date: October 11, 1999 Document Number: COS-01-0002 Revision: Initial Release Contract No.: NAS5-98043 CDRL No. AV-02 Prepared By: S. Osterman, COS Optical Scientist, CU/CASA Date Reviewed By: E. Wilkinson, COS Instrument Scientist, CU/CASA Date

  15. COS G160M FUV Grating Calibration and Qualification Plan

    E-Print Network [OSTI]

    Colorado at Boulder, University of

    COS G160M FUV Grating Calibration and Qualification Plan Date: January 4, 2001 Document Number: COS-01-0005 Revision: Initial Release Contract No.: NAS5-98043 CDRL No. Prepared By: S. Osterman, COS Optical Scientist, CU/CASA Date Reviewed By: E. Wilkinson, COS Instrument Scientist, CU/CASA Date Approved

  16. COS G140L FUV Grating Calibration and Qualification Plan

    E-Print Network [OSTI]

    Colorado at Boulder, University of

    COS G140L FUV Grating Calibration and Qualification Plan Date: January 4, 2001 Document Number: COS-01-0004 Revision: Initial Release Contract No.: NAS5-98043 CDRL No. Prepared By: S. Osterman, COS Optical Scientist, CU/CASA Date Reviewed By: E. Wilkinson, COS Instrument Scientist, CU/CASA Date Approved

  17. Ultra Bright LED Light Injection Calibration System for MINOS

    E-Print Network [OSTI]

    B. Anderson; A. Anjomshoaa; P. Dervan; J. A. Lauber; J. Thomas

    1998-10-26

    We describe here a proposal for a light injection calibration system for the MINOS detectors based on ultra bright blue LEDs as the light source. We have shown that these LEDs are bright enough to span over two orders of magnitude in light intensity, commensurate with that expected in a single scintillator strip in the MINOS neutrino detectors.

  18. Calibrated Continuous-Time Sigma-Delta Modulators 

    E-Print Network [OSTI]

    Lu, Cho-Ying

    2010-07-14

    and SNR simulations vs. the number of iterations of the calibration scheme for PVT variations on the modulator .......................................................................................... 94 xiii? ? ? ? Page Fig. 4...-time ?? ADC with immunity to the process, voltage, temperature (PVT) variations by using capacitor ratios to determine the system coefficients, one of the critical issues of a continuous-time ?? ADC is its high sensitivity to the variations due...

  19. Bayesian Calibration of the Community Land Model using Surrogates

    SciTech Connect (OSTI)

    Ray, Jaideep; Hou, Zhangshuan; Huang, Maoyi; Sargsyan, K.; Swiler, Laura P.

    2015-01-01

    We present results from the Bayesian calibration of hydrological parameters of the Community Land Model (CLM), which is often used in climate simulations and Earth system models. A statistical inverse problem is formulated for three hydrological parameters, conditioned on observations of latent heat surface fluxes over 48 months. Our calibration method uses polynomial and Gaussian process surrogates of the CLM, and solves the parameter estimation problem using a Markov chain Monte Carlo sampler. Posterior probability densities for the parameters are developed for two sites with different soil and vegetation covers. Our method also allows us to examine the structural error in CLM under two error models. We find that accurate surrogate models can be created for CLM in most cases. The posterior distributions lead to better prediction than the default parameter values in CLM. Climatologically averaging the observations does not modify the parameters’ distributions significantly. The structural error model reveals a correlation time-scale which can potentially be used to identify physical processes that could be contributing to it. While the calibrated CLM has a higher predictive skill, the calibration is under-dispersive.

  20. Neutron calibration sources in the Daya Bay experiment

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Liu, J.; Carr, R.; Dwyer, D. A.; Gu, W. Q.; Li, G. S.; McKeown, R. D.; Qian, X.; Tsang, R. H. M.; Wu, F. F.; Zhang, C.

    2015-07-09

    We describe the design and construction of the low rate neutron calibration sources used in the Daya Bay Reactor Anti-neutrino Experiment. Such sources are free of correlated gamma-neutron emission, which is essential in minimizing induced background in the anti-neutrino detector. Thus, the design characteristics have been validated in the Daya Bay anti-neutrino detector.

  1. Sensor Localization and Camera Calibration using Low Power Cameras

    E-Print Network [OSTI]

    Savvides, Andreas

    Sensor Localization and Camera Calibration using Low Power Cameras Dimitrios Lymberopoulos, Andrew low-power imagers offer an information rich sensing modality that can detect fea- tures from a scene with a COTS camera module, similar to the one used in cellphones. To experiment with camera related sensor

  2. Micro-pixel accuracy centroid displacement estimation and detector calibration

    E-Print Network [OSTI]

    Masci, Frank

    Shao, Renaud Goullioud, and Bijan Nemati Jet Propulsion Laboratory, California Institute of Technology of the inter-pixel variations of pixel response functions can be conveniently expressed in terms of powers of spatial wave numbers using their Taylor series expansions. Calibrating up to the third order terms

  3. Cloud-Based Model Calibration Using OpenStudio: Preprint

    SciTech Connect (OSTI)

    Hale, E.; Lisell, L.; Goldwasser, D.; Macumber, D.; Dean, J.; Metzger, I.; Parker, A.; Long, N.; Ball, B.; Schott, M.; Weaver, E.; Brackney, L.

    2014-03-01

    OpenStudio is a free, open source Software Development Kit (SDK) and application suite for performing building energy modeling and analysis. The OpenStudio Parametric Analysis Tool has been extended to allow cloud-based simulation of multiple OpenStudio models parametrically related to a baseline model. This paper describes the new cloud-based simulation functionality and presents a model cali-bration case study. Calibration is initiated by entering actual monthly utility bill data into the baseline model. Multiple parameters are then varied over multiple iterations to reduce the difference between actual energy consumption and model simulation results, as calculated and visualized by billing period and by fuel type. Simulations are per-formed in parallel using the Amazon Elastic Cloud service. This paper highlights model parameterizations (measures) used for calibration, but the same multi-nodal computing architecture is available for other purposes, for example, recommending combinations of retrofit energy saving measures using the calibrated model as the new baseline.

  4. AN H-BAND SPECTROSCOPIC METALLICITY CALIBRATION FOR M DWARFS

    SciTech Connect (OSTI)

    Terrien, Ryan C.; Mahadevan, Suvrath; Bender, Chad F.; Deshpande, Rohit; Ramsey, Lawrence W.; Bochanski, John J., E-mail: rct151@psu.edu [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States)

    2012-03-10

    We present an empirical near-infrared (NIR) spectroscopic method for estimating M dwarf metallicities, based on features in the H band, as well as an implementation of a similar published method in the K band. We obtained R {approx} 2000 NIR spectra of a sample of M dwarfs using the NASA IRTF-SpeX spectrograph, including 22 M dwarf metallicity calibration targets that have FGK companions with known metallicities. The H-band and K-band calibrations provide equivalent fits to the metallicities of these binaries, with an accuracy of {+-}0.12 dex. We derive the first empirically calibrated spectroscopic metallicity estimate for the giant planet-hosting M dwarf GJ 317, confirming its supersolar metallicity. Combining this result with observations of eight other M dwarf planet hosts, we find that M dwarfs with giant planets are preferentially metal-rich compared to those that host less massive planets. Our H-band calibration relies on strongly metallicity-dependent features in the H band, which will be useful in compositional studies using mid- to high-resolution NIR M dwarf spectra, such as those produced by multiplexed surveys like SDSS-III APOGEE. These results will also be immediately useful for ongoing spectroscopic surveys of M dwarfs.

  5. Pressure Calibration by the Infrared Absorption Spectrum of Mineral Oil

    E-Print Network [OSTI]

    Collins, Gary S.

    Pressure Calibration by the Infrared Absorption Spectrum of Mineral Oil H. Child, Kenyon College effect is seen in the infrared absorption spectrum of mineral oil. The frequency of two peaks increases as pressure is applied to the mineral oil. At a pressure of about 1 kbar (100 MPa), both peaks are distinct

  6. CALIBRATION Parts Set version 8/10/99 STARDUST SPACECRAFT

    E-Print Network [OSTI]

    SOLAR PANELS PANEL STIFFENER PANEL STIFFENER WHIPPLE SHIELDWHIPPLE SHIELD SHIELD SPACERS SHIELD SPACERS-classroom use must be obtained from JPL Commercial Programs Office. #12;X X - Z PANEL REM STAR CAMERAS + Z PANEL X X CUT OUT PRINTING CALIBRATION STARDUST SPACECRAFT Scale Model Parts SHEET 2 + Y PANEL - Y PANEL

  7. Gearbox Reliability Collaborative High Speed Shaft Tapered Roller Bearing Calibration

    SciTech Connect (OSTI)

    Keller, J.; Guo, Y.; McNiff, B.

    2013-10-01

    The National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) is a project investigating gearbox reliability primarily through testing and modeling. Previous dynamometer testing focused upon acquiring measurements in the planetary section of the test gearbox. Prior to these tests, the strain gages installed on the planetary bearings were calibrated in a load frame.

  8. Using Utility Information to Calibrate Customer Demand Management Behavior Models

    E-Print Network [OSTI]

    Using Utility Information to Calibrate Customer Demand Management Behavior Models Murat Fahrio ­ Madison Report PSerc 99­06 June 10, 1999 Abstract In times of stress customers can help a utility by means be optimized if the utility can estimate the outage or substitution costs of its customers. This report

  9. Chronological information and uncertainty Radiocarbon dating & calibration -Paula Reimer

    E-Print Network [OSTI]

    Sengun, Mehmet Haluk

    uncertainty · Estimated ± 1 - 2 (± 8-32 years) · Measured off-line ± 0.2 (± 2) - ok in gas counting systems.17 (lab error multiplier) #12;14C calibration uncertainties Animation: M. Blaauw #12;Constant initial 14C interpol. Too much weight on individual dates? #12;Which age-depth model? 800 cm core 9 14 C dates

  10. The HAWC Gamma-Ray Observatory: Design, Calibration, and Operation

    E-Print Network [OSTI]

    Abeysekara, A U; Alvarez, C; Álvarez, J D; Arceo, R; Arteaga-Velázquez, J C; Solares, H A Ayala; Barber, A S; Baughman, B M; Bautista-Elivar, N; Belmont, E; BenZvi, S Y; Berley, D; Rosales, M Bonilla; Braun, J; Caballero-Lopez, R A; Caballero-Mora, K S; Carramiñana, A; Castillo, M; Cotti, U; Cotzomi, J; de la Fuente, E; De León, C; DeYoung, T; Hernandez, R Diaz; Díaz-Vélez, J C; Dingus, B L; DuVernois, M A; Ellsworth, R W; Fernandez, A; Fiorino, D W; Fraija, N; Galindo, A; Garfias, F; González, L X; González, M M; Goodman, J A; Grabski, V; Gussert, M; Hampel-Arias, Z; Hui, C M; Hüntemeyer, P; Imran, A; Iriarte, A; Karn, P; Kieda, D; Kunde, G J; Lara, A; Lauer, R J; Lee, W H; Lennarz, D; Vargas, H León; Linares, E C; Linnemann, J T; Longo, M; Luna-GarcIa, R; Marinelli, A; Martinez, H; Martinez, O; Martínez-Castro, J; Matthews, J A J; Miranda-Romagnoli, P; Moreno, E; Mostafá, M; Nava, J; Nellen, L; Newbold, M; Noriega-Papaqui, R; Oceguera-Becerra, T; Patricelli, B; Pelayo, R; Pérez-Pérez, E G; Pretz, J; Rivière, C; Rosa-González, D; Salazar, H; Salesa, F; Sanchez, F E; Sandoval, A; Santos, E; Schneider, M; Silich, S; Sinnis, G; Smith, A J; Sparks, K; Springer, R W; Taboada, I; Toale, P A; Tollefson, K; Torres, I; Ukwatta, T N; Villaseñor, L; Weisgarber, T; Westerhoff, S; Wisher, I G; Wood, J; Yodh, G B; Younk, P W; Zaborov, D; Zepeda, A; Zhou, H

    2013-01-01

    The High-Altitude Water Cherenkov Gamma Ray Observatory (HAWC) is under construction 4100 meters above sea level at Sierra Negra, Mexico. We describe the design and cabling of the detector, the characterization of the photomultipliers, and the timing calibration system. We also outline a next-generation detector based on the water Cherenkov technique.

  11. Revised absolute amplitude calibration of the LOPES experiment

    E-Print Network [OSTI]

    Link, K; Apel, W D; Arteaga-Velázquez, J C; Bähren, L; Bekk, K; Bertaina, M; Biermann, P L; Blümer, J; Bozdog, H; Brancus, I M; Cantoni, E; Chiavassa, A; Daumiller, K; de Souza, V; Di Pierro, F; Doll, P; Engel, R; Falcke, H; Fuchs, B; Gemmeke, H; Grupen, C; Haungs, A; Heck, D; Hiller, R; Hörandel, J R; Horneffer, A; Huber, D; Isar, P G; Kampert, K-H; Kang, D; Krömer, O; Kuijpers, J; ?uczak, P; Ludwig, M; Mathes, H J; Melissas, M; Morello, C; Oehlschläger, J; Palmieri, N; Pierog, T; Rautenberg, J; Rebel, H; Roth, M; Rühle, C; Saftoiu, A; Schieler, H; Schmidt, A; Schoo, S; Schröder, F G; Sima, O; Toma, G; Trinchero, G C; Weindl, A; Wochele, J; Zabierowski, J; Zensus, J A

    2015-01-01

    One of the main aims of the LOPES experiment was the evaluation of the absolute amplitude of the radio signal of air showers. This is of special interest since the radio technique offers the possibility for an independent and highly precise determination of the energy scale of cosmic rays on the basis of signal predictions from Monte Carlo simulations. For the calibration of the amplitude measured by LOPES we used an external source. Previous comparisons of LOPES measurements and simulations of the radio signal amplitude predicted by CoREAS revealed a discrepancy of the order of a factor of two. A re-measurement of the reference calibration source, now performed for the free field, was recently performed by the manufacturer. The updated calibration values lead to a lowering of the reconstructed electric field measured by LOPES by a factor of $2.6 \\pm 0.2$ and therefore to a significantly better agreement with CoREAS simulations. We discuss the updated calibration and its impact on the LOPES analysis results.

  12. Revised absolute amplitude calibration of the LOPES experiment

    E-Print Network [OSTI]

    K. Link; T. Huege; W. D. Apel; J. C. Arteaga-Velázquez; L. Bähren; K. Bekk; M. Bertaina; P. L. Biermann; J. Blümer; H. Bozdog; I. M. Brancus; E. Cantoni; A. Chiavassa; K. Daumiller; V. de Souza; F. Di Pierro; P. Doll; R. Engel; H. Falcke; B. Fuchs; H. Gemmeke; C. Grupen; A. Haungs; D. Heck; R. Hiller; J. R. Hörandel; A. Horneffer; D. Huber; P. G. Isar; K-H. Kampert; D. Kang; O. Krömer; J. Kuijpers; P. ?uczak; M. Ludwig; H. J. Mathes; M. Melissas; C. Morello; J. Oehlschläger; N. Palmieri; T. Pierog; J. Rautenberg; H. Rebel; M. Roth; C. Rühle; A. Saftoiu; H. Schieler; A. Schmidt; S. Schoo; F. G. Schröder; O. Sima; G. Toma; G. C. Trinchero; A. Weindl; J. Wochele; J. Zabierowski; J. A. Zensus

    2015-08-14

    One of the main aims of the LOPES experiment was the evaluation of the absolute amplitude of the radio signal of air showers. This is of special interest since the radio technique offers the possibility for an independent and highly precise determination of the energy scale of cosmic rays on the basis of signal predictions from Monte Carlo simulations. For the calibration of the amplitude measured by LOPES we used an external source. Previous comparisons of LOPES measurements and simulations of the radio signal amplitude predicted by CoREAS revealed a discrepancy of the order of a factor of two. A re-measurement of the reference calibration source, now performed for the free field, was recently performed by the manufacturer. The updated calibration values lead to a lowering of the reconstructed electric field measured by LOPES by a factor of $2.6 \\pm 0.2$ and therefore to a significantly better agreement with CoREAS simulations. We discuss the updated calibration and its impact on the LOPES analysis results.

  13. Bayesian calibration of the Community Land Model using surrogates

    SciTech Connect (OSTI)

    Ray, Jaideep; Hou, Zhangshuan; Huang, Maoyi; Swiler, Laura Painton

    2014-02-01

    We present results from the Bayesian calibration of hydrological parameters of the Community Land Model (CLM), which is often used in climate simulations and Earth system models. A statistical inverse problem is formulated for three hydrological parameters, conditional on observations of latent heat surface fluxes over 48 months. Our calibration method uses polynomial and Gaussian process surrogates of the CLM, and solves the parameter estimation problem using a Markov chain Monte Carlo sampler. Posterior probability densities for the parameters are developed for two sites with different soil and vegetation covers. Our method also allows us to examine the structural error in CLM under two error models. We find that surrogate models can be created for CLM in most cases. The posterior distributions are more predictive than the default parameter values in CLM. Climatologically averaging the observations does not modify the parameters' distributions significantly. The structural error model reveals a correlation time-scale which can be used to identify the physical process that could be contributing to it. While the calibrated CLM has a higher predictive skill, the calibration is under-dispersive.

  14. Calibrated Probabilistic Forecasting at the Stateline Wind Energy Center

    E-Print Network [OSTI]

    Washington at Seattle, University of

    Calibrated Probabilistic Forecasting at the Stateline Wind Energy Center: The Regime at wind energy sites are becoming paramount. Regime-switching space-time (RST) models merge meteorological forecast regimes at the wind energy site and fits a conditional predictive model for each regime

  15. Calibration of hydraulic and tracer tests in fractured media

    E-Print Network [OSTI]

    Politècnica de Catalunya, Universitat

    Calibration of hydraulic and tracer tests in fractured media represented by a DFN Model L. D. Donado, X. Sanchez-Vila, E. Ruiz* & F. J. Elorza** * Enviros Spain S.L. ** UPM #12;Fractured Media Water flows through fractures (matrix basically impervious ­ though relevant to transport) Fractures at all

  16. TDR calibration for the alternative landfill cover demonstration (ALCD)

    SciTech Connect (OSTI)

    Lopez, J.; Dwyer, S.F.; Swanson, J.N.

    1997-09-01

    The Alternative Landfill Cover Demonstration is a large scale field test that compares the performance of various landfill cover designs in dry environments. An important component of the comparison is the change in the moisture content of the soils throughout the different cover test plots. Time Domain Reflectometry (TDR) is the primary method for the measurement of the volumetric moisture content. Each of the covers is composed of layers of varying types and densities of soils. The probes are therefore calibrated to calculate the volumetric moisture content in each of the different soils in order to gain the optimum performance of the TDR system. The demonstration plots are constructed in two phases; a different probe is used in each phase. The probe that is used in Phase 1 is calibrated for the following soils: compacted native soil, uncompacted native soil, compacted native soil mixed with 6% sodium bentonite by weight, and sand. The probe that is used in Phase 2 is calibrated for the following soils: compacted native soil, uncompacted native soil, and sand. In addition, the probes are calibrated for the varying cable lengths of the TDR probes. The resulting empirically derived equations allow for the calculation of in-situ volumetric moisture content of all of the varying soils throughout the cover test plots in the demonstration.

  17. ARTICULATORY SPACE CALIBRATION IN 3D ELECTRO-MAGNETIC ARTICULOGRAPHY

    E-Print Network [OSTI]

    Johnson, Michael T.

    articulatory space. A bite plate record for a target subject is used to define the maxillary occlusal collected using NDI Wave Speech Research System for one pilot subject, and calibration results of articulatory kinematics and relationship to acoustics. Index Terms-- Electro-Magnetic Articulography

  18. A Calibration Bound for the M-Theory Fivebrane

    E-Print Network [OSTI]

    O. Baerwald; N. D. Lambert; P. C. West

    1999-08-13

    We construct a covariant bound on the energy-momentum of the M-fivebrane which is saturated by all supersymmetric configurations. This leads to a generalised notion of a calibrated geometry for M-fivebranes when the worldvolume gauge field is non-zero. The generalisation relevant for Dp-branes is also given.

  19. CMR Shuffler System: Passive Mode Calibration and Certification Report

    SciTech Connect (OSTI)

    Frame, Katherine C. [Los Alamos National Laboratory; Gomez, Cipriano D. [Retired CMR-OPS: OPERATIONS; Salazar, William R. [Los Alamos National Laboratory; Mayo, Douglas R. [Los Alamos National Laboratory; Vigil, Georgiana M. [Los Alamos National Laboratory; Crooks, William J. [Los Alamos National Laboratory; Stange, Sy [Los Alamos National Laboratory

    2012-07-20

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. As debris is removed from the vessels, material will be placed in waste drums. Far-field gamma ray assay will be used to determine when a drum is nearing a {sup 239}Pu equivalent mass of less than 200 g. The drum will then be assayed using a waste drum shuffler operated in passive mode using a neutron coincidence counting method for accountability. This report focuses on the testing and calibration of the CMR waste drum shuffler in passive mode operation. Initial testing was performed to confirm previously accepted measurement parameters. The system was then calibrated using a set of weapons grade Pu (WGPu, {sup 239}Pu > 93%) oxide standards placed inside a 55 gallon drum. The calibration data ranges from Pu mass of 0.5 g to 188.9 g. The CMR waste drum shuffler has been tested and calibrated in passive mode in preparation for safeguards accountability measurements of waste drums containing material removed from CVs for the CVD project.

  20. Confinement Vessel Assay System: Calibration and Certification Report

    SciTech Connect (OSTI)

    Frame, Katherine C. [Los Alamos National Laboratory; Bourne, Mark M. [Los Alamos National Laboratory; Crooks, William J. [Los Alamos National Laboratory; Evans, Louise [Los Alamos National Laboratory; Gomez, Cipriano [Retired CMR-OPS: OPERATIONS; Mayo, Douglas R. [Los Alamos National Laboratory; Miko, David K. [Los Alamos National Laboratory; Salazar, William R. [Los Alamos National Laboratory; Stange, Sy [Los Alamos National Laboratory; Vigil, Georgiana M. [Los Alamos National Laboratory

    2012-07-17

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of SNM in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of {le} 100-g {sup 239}Pu equivalent in a vessel for safeguards termination. The system was calibrated in three different mass regions (low, medium, and high) to cover the entire plutonium mass range that will be assayed. The low mass calibration and medium mass calibration were verified for material positioned in the center of an empty vessel. The systematic uncertainty due to position bias was estimated using an MCNPX model to simulate the response of the system to material localized at various points along the inner surface of the vessel. The background component due to cosmic ray spallation was determined by performing measurements of an empty vessel and comparing to measurements in the same location with no vessel present. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements of CVs before and after cleanout.

  1. Dependency of EBT2 film calibration curve on postirradiation time

    SciTech Connect (OSTI)

    Chang, Liyun, E-mail: liyunc@isu.edu.tw; Ding, Hueisch-Jy [Department of Medical Imaging and Radiological Sciences, I-Shou University, Kaohsiung 82445, Taiwan (China)] [Department of Medical Imaging and Radiological Sciences, I-Shou University, Kaohsiung 82445, Taiwan (China); Ho, Sheng-Yow [Department of Radiation Oncology, Chi Mei Medical Center, Liouying, Tainan 73657, Taiwan (China)] [Department of Radiation Oncology, Chi Mei Medical Center, Liouying, Tainan 73657, Taiwan (China); Lee, Tsair-Fwu [Medical Physics and Informatics Laboratory, Department of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung 80778, Taiwan (China)] [Medical Physics and Informatics Laboratory, Department of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung 80778, Taiwan (China); Chen, Pang-Yu, E-mail: pangyuchen@yahoo.com.tw [Department of Radiation Oncology, Sinlau Christian Hospital, Tainan 70142, Taiwan (China)] [Department of Radiation Oncology, Sinlau Christian Hospital, Tainan 70142, Taiwan (China)

    2014-02-15

    Purpose: The Ashland Inc. product EBT2 film model is a widely used quality assurance tool, especially for verification of 2-dimensional dose distributions. In general, the calibration film and the dose measurement film are irradiated, scanned, and calibrated at the same postirradiation time (PIT), 1-2 days after the films are irradiated. However, for a busy clinic or in some special situations, the PIT for the dose measurement film may be different from that of the calibration film. In this case, the measured dose will be incorrect. This paper proposed a film calibration method that includes the effect of PIT. Methods: The dose versus film optical density was fitted to a power function with three parameters. One of these parameters was PIT dependent, while the other two were found to be almost constant with a standard deviation of the mean less than 4%. The PIT-dependent parameter was fitted to another power function of PIT. The EBT2 film model was calibrated using the PDD method with 14 different PITs ranging from 1 h to 2 months. Ten of the fourteen PITs were used for finding the fitting parameters, and the other four were used for testing the model. Results: The verification test shows that the differences between the delivered doses and the film doses calculated with this modeling were mainly within 2% for delivered doses above 60 cGy, and the total uncertainties were generally under 5%. The errors and total uncertainties of film dose calculation were independent of the PIT using the proposed calibration procedure. However, the fitting uncertainty increased with decreasing dose or PIT, but stayed below 1.3% for this study. Conclusions: The EBT2 film dose can be modeled as a function of PIT. For the ease of routine calibration, five PITs were suggested to be used. It is recommended that two PITs be located in the fast developing period (1?6 h), one in 1 ? 2 days, one around a week, and one around a month.

  2. A Laser Range Scanner Designed for Minimum Calibration Complexity James Davis, Xing Chen

    E-Print Network [OSTI]

    Stanford University

    A Laser Range Scanner Designed for Minimum Calibration Complexity James Davis, Xing Chen Computer Graphics Lab, Stanford University {jedavis, xcchen}@graphics.stanford.edu Abstract Laser range scanners reduce the costs associated with calibration. 1 Introduction Laser triangulation scanners

  3. Algorithmic and implementation aspects of on-line calibration of Dynamic Traffic Assignment

    E-Print Network [OSTI]

    Huang, Enyang

    2010-01-01

    This thesis compares alternative and proposes new candidate algorithms for the online calibration of Dynamic Traffic Assignment (DTA). The thesis presents two formulations to on-line calibration: 1) The classical statespace ...

  4. Nash equilibrium in a game of calibration Omar Glonti, Peter Harremoes, Zaza Khechinashvili

    E-Print Network [OSTI]

    Topsøe, Flemming

    , a problem of calibration in a simple model of stock price development is treated. A quantitative method

  5. BATON ROUGE METRO AIRPORT

    E-Print Network [OSTI]

    Harms, Kyle E.

    STATE ID AND SURRENDER CERTIFICATE TO CASHIER ALONG WITH PARKING TICKET WHEN EXITING FROM LOT. PARKING WITH PARKING TICKET WHEN EXITING FROM LOT. PARKING SERVICES PROVIDED BY STANDARD PARKING, INC. 225-355-2978 Use STATE ID AND SURRENDER CERTIFICATE TO CASHIER ALONG WITH PARKING TICKET WHEN EXITING FROM LOT. PARKING

  6. Easterwood Airport - 15 

    E-Print Network [OSTI]

    Unknown

    2009-01-01

    175 200 225 250 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2 Mean (mm) De p t h ( c m) Fig. 16. Mean grain size graph for core 4B 26 Fig. 17. Stratigraphic transect profile #1. % Sand Mean Size 27 In transect #1 in the north... 125 150 175 200 225 250 0.00 0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 0.18 0.20 Mean (mm) Dep t h (cm) 25 26 Core: TXD-1D Particle Size Distribution 0.1 1 10 100 1000 Particle...

  7. La Guardia Airport Background

    E-Print Network [OSTI]

    , which was grandfathered in -- so most transcontinental and international flights use the area's other

  8. Relationship between morphologies and orientations of Cu{sub 6}Sn{sub 5} grains in Sn3.0Ag0.5Cu solder joints on different Cu pads

    SciTech Connect (OSTI)

    Tian, Yanhong, E-mail: tianyh@hit.edu.cn; Zhang, Rui; Hang, Chunjin; Niu, Lina; Wang, Chunqing

    2014-02-15

    The morphologies and orientations of Cu{sub 6}Sn{sub 5} intermetallic compounds in the Sn3.0Ag0.5Cu solder joints both on polycrystalline and single crystal Cu pads under different peak reflow temperatures and times above liquids were investigated. The relationship between Cu{sub 6}Sn{sub 5} grain orientations and morphologies was clarified. At the interface of Sn3.0Ag0.5Cu/polycrystalline Cu pad, scalloped Cu{sub 6}Sn{sub 5} intermetallic compounds formed at 250 °C and roof shape Cu{sub 6}Sn{sub 5} formed at 300 °C. Both scalloped Cu{sub 6}Sn{sub 5} and roof shape Cu{sub 6}Sn{sub 5} had a preferred orientation of (0001) plane being parallel to polycrystalline Cu pad surface. Besides, the percentage of large angle grain boundaries increased as the peak reflow temperature rose. At the interface of Sn3.0Ag0.5Cu/(111) single crystal Cu pad, the Cu{sub 6}Sn{sub 5} intermetallic compounds were mainly scallop-type at 250 °C and were prism type at 300 °C. The prismatic Cu{sub 6}Sn{sub 5} grains grew along the three preferred directions with the inter-angles of 60° on (111) single crystal Cu pad while along two perpendicular directions on (100) single crystal Cu pad. The orientation relationship between Cu{sub 6}Sn{sub 5} grains and the single crystal Cu pads was investigated by electron backscatter diffraction technology. In addition, two types of hollowed Cu{sub 6}Sn{sub 5} intermetallic compounds were found inside the joints of polycrystalline Cu pads. The long hexagonal Cu{sub 6}Sn{sub 5} strips were observed in the joints reflowing at 250 °C while the hollowed Cu{sub 6}Sn{sub 5} strips with the ‘?’ shape cross-sections appeared at 300 °C, which was attributed to the different grain growth rates of different Cu{sub 6}Sn{sub 5} crystal faces. - Highlights: • The orientation of interfacial Cu{sub 6}Sn{sub 5} grains was obtained by EBSD technology. • Two types of hollowed Cu{sub 6}Sn{sub 5} strips were found at different temperatures. • The formation mechanism of hollowed Cu{sub 6}Sn{sub 5} was elaborated based on Bravais law. • The relationship between Cu{sub 6}Sn{sub 5} grain orientations and morphologies was clarified.

  9. SOIL TEST CALIBRATION WORK IN SOUTHERN USA Leticia S. Sonon and Hailin Zhang

    E-Print Network [OSTI]

    SOIL TEST CALIBRATION WORK IN SOUTHERN USA Leticia S. Sonon and Hailin Zhang Introduction Sound soil test calibration is essential for successful fertilization program and crop production. It is essential that the results of soil tests be calibrated against crop responses from applications of the plant

  10. Using Parallel MCMC Sampling to Calibrate a Computer Model of a Geothermal Reservoir

    E-Print Network [OSTI]

    Fox, Colin

    Using Parallel MCMC Sampling to Calibrate a Computer Model of a Geothermal Reservoir by T. Cui, C. 686 ISSN 1178-360 #12;Using Parallel MCMC Sampling to Calibrate a Computer Model of a Geothermal of a geothermal field to achieve model `calibration' from measured well-test data. We explore three scenarios

  11. Calibrating the sensing-coil radius by feed-down from a harmonic reference

    E-Print Network [OSTI]

    Arpaia, Pasquale; Koster, Oliver; Russenschuck, Stephan; Severino, Giordana

    2015-01-01

    A method for calibrating the radius of rotating, harmonic sensing coils is proposed that allows relaxing constraints on alignment and field errors of the reference quadrupole magnet. Radius calibration considering roll angle misalignment between the measurement bench, the magnet, and the motor-drive unit is studied first. We then study the calibration error when

  12. PV Cell and Module Calibration Activities at NREL

    SciTech Connect (OSTI)

    Emery, K.; Anderberg, A.; Kiehl, J.; Mack, C.; Moriarty, T.; Ottoson, L.; Rummel, S.

    2005-11-01

    The performance of PV cells and modules with respect to standard reference conditions is a key indicator of progress of a given technology. This task provides the U.S. terrestrial PV community with the most accurate measurements that are technically possible in a timely fashion. The international module certification and accreditation program PVGap requires certification laboratories to maintain their calibration traceability path to groups like this one. The politics of a "world record" efficiency requires that an independent laboratory perform these measurements for credibility. Most manufacturers base their module peak watt rating upon standards and reference cells calibrated under this task. This task has been involved in reconciling disputes between manufacturers and their cell suppliers in terms of expected versus actual performance. This task has also served as a resource to the PV community for consultation on solar simulation, current versus voltage measurement instrumentation, measurement procedures and measurement artifacts.

  13. Wavelength calibration of the JWST-MIRI medium resolution spectrometer

    E-Print Network [OSTI]

    Martinez-Galarza, J R; Hernan-Caballero, A; Azzollini, R; Glasse, A; Kendrew, S; Brandl, B; Lahuis, F

    2010-01-01

    We present the wavelength and spectral resolution characterisation of the Integral Field Unit (IFU) Medium Resolution Spectrometer for the Mid-InfraRed Instrument (MIRI), to fly onboard the James Webb Space Telescope in 2014. We use data collected using the Verification Model of the instrument and develop an empirical method to calibrate properties such as wavelength range and resolving power in a portion of the spectrometer's full spectral range (5-28 microns). We test our results against optical models to verify the system requirements and combine them with a study of the fringing pattern in the instrument's detector to provide a more accurate calibration. We show that MIRI's IFU spectrometer will be able to produce spectra with a resolving power above R=2800 in the wavelength range 6.46-7.70 microns, and that the unresolved spectral lines are well fitted by a Gaussian profile.

  14. Liquid Argon Cryogenic Detector Calibration by Inelastic Scattering of Neutrons

    E-Print Network [OSTI]

    Sergey Polosatkin; Evgeny Grishnyaev; Alexander Dolgov

    2014-07-10

    A method for calibration of cryogenic liquid argon detector response to recoils with certain energy -8.2 keV - is proposed. The method utilizes a process of inelastic scattering of monoenergetic neutrons produced by fusion DD neutron generator. Features of kinematics of inelastic scattering cause sufficient (forty times) increase in count rate of useful events relative to traditional scheme exploited elastic scattering with the same recoil energy and compatible energy resolution. The benefits of the proposed scheme of calibration most well implemented with the use of tagged neutron generator as a neutron source that allows to eliminate background originated from casual coincidence of signals on cryogenic detector and additional detector of scattered neutrons.

  15. Paper II: Calibration of the Swift ultraviolet/optical telescope

    E-Print Network [OSTI]

    Breeveld, A A; Hoversten, E A; Koch, S; Landsman, W; Marshall, F E; Page, M J; Poole, T S; Roming, P; Smith, P J; Still, M; Yershov, V; Blustin, A J; Brown, P J; Gronwall, C; Holland, S T; Kuin, N P M; McGowan, K; Rosen, S; Boyd, P; Broos, P; Carter, M; Chester, M M; Hancock, B; Huckle, H; Immler, S; Ivanushkina, M; Kennedy, T; Mason, K O; Morgan, A N; Oates, S; de Pasquale, M; Schady, P; Siegel, M; Berk, D Vanden

    2010-01-01

    The Ultraviolet/Optical Telescope (UVOT) is one of three instruments onboard the Swift observatory. The photometric calibration has been published, and this paper follows up with details on other aspects of the calibration including a measurement of the point spread function with an assessment of the orbital variation and the effect on photometry. A correction for large scale variations in sensitivity over the field of view is described, as well as a model of the coincidence loss which is used to assess the coincidence correction in extended regions. We have provided a correction for the detector distortion and measured the resulting internal astrometric accuracy of the UVOT, also giving the absolute accuracy with respect to the International Celestial Reference System. We have compiled statistics on the background count rates, and discuss the sources of the background, including instrumental scattered light. In each case we describe any impact on UVOT measurements, whether any correction is applied in the st...

  16. Calibration of fluorescence resonance energy transfer in microscopy

    DOE Patents [OSTI]

    Youvan, Dougalas C.; Silva, Christopher M.; Bylina, Edward J.; Coleman, William J.; Dilworth, Michael R.; Yang, Mary M.

    2003-12-09

    Imaging hardware, software, calibrants, and methods are provided to visualize and quantitate the amount of Fluorescence Resonance Energy Transfer (FRET) occurring between donor and acceptor molecules in epifluorescence microscopy. The MicroFRET system compensates for overlap among donor, acceptor, and FRET spectra using well characterized fluorescent beads as standards in conjunction with radiometrically calibrated image processing techniques. The MicroFRET system also provides precisely machined epifluorescence cubes to maintain proper image registration as the sample is illuminated at the donor and acceptor excitation wavelengths. Algorithms are described that pseudocolor the image to display pixels exhibiting radiometrically-corrected fluorescence emission from the donor (blue), the acceptor (green) and FRET (red). The method is demonstrated on samples exhibiting FRET between genetically engineered derivatives of the Green Fluorescent Protein (GFP) bound to the surface of Ni chelating beads by histidine-tags.

  17. Calibration of fluorescence resonance energy transfer in microscopy

    DOE Patents [OSTI]

    Youvan, Douglas C. (San Jose, CA); Silva, Christopher M. (Sunnyvale, CA); Bylina, Edward J. (San Jose, CA); Coleman, William J. (Moutain View, CA); Dilworth, Michael R. (Santa Cruz, CA); Yang, Mary M. (San Jose, CA)

    2002-09-24

    Imaging hardware, software, calibrants, and methods are provided to visualize and quantitate the amount of Fluorescence Resonance Energy Transfer (FRET) occurring between donor and acceptor molecules in epifluorescence microscopy. The MicroFRET system compensates for overlap among donor, acceptor, and FRET spectra using well characterized fluorescent beads as standards in conjunction with radiometrically calibrated image processing techniques. The MicroFRET system also provides precisely machined epifluorescence cubes to maintain proper image registration as the sample is illuminated at the donor and acceptor excitation wavelengths. Algorithms are described that pseudocolor the image to display pixels exhibiting radiometrically-corrected fluorescence emission from the donor (blue), the acceptor (green) and FRET (red). The method is demonstrated on samples exhibiting FRET between genetically engineered derivatives of the Green Fluorescent Protein (GFP) bound to the surface of Ni chelating beads by histidine-tags.

  18. Model- and calibration-independent test of cosmic acceleration

    E-Print Network [OSTI]

    Marina Seikel; Dominik J. Schwarz

    2009-01-27

    We present a calibration-independent test of the accelerated expansion of the universe using supernova type Ia data. The test is also model-independent in the sense that no assumptions about the content of the universe or about the parameterization of the deceleration parameter are made and that it does not assume any dynamical equations of motion. Yet, the test assumes the universe and the distribution of supernovae to be statistically homogeneous and isotropic. A significant reduction of systematic effects, as compared to our previous, calibration-dependent test, is achieved. Accelerated expansion is detected at significant level (4.3 sigma in the 2007 Gold sample, 7.2 sigma in the 2008 Union sample) if the universe is spatially flat. This result depends, however, crucially on supernovae with a redshift smaller than 0.1, for which the assumption of statistical isotropy and homogeneity is less well established.

  19. Calibration of the HAO standard opal filter set. Technical note

    SciTech Connect (OSTI)

    Streete, J.L.

    1989-10-01

    Solar radiation attenuators called opal filters have been used for several decades to calibrate photographic film in instruments used to measure the brightness of the solar corona. The primary component used in fabricating these filters is opal glass. New measurements of the transmittance of the HAO fundamental standard set of opal filters were begun in September, 1988. Since nearly two decades had passed from the time of the last calibration measurements, there was concern that the transmittance of the filters might have changed. Another motivation for recalibrating the opal filters was the desire to know the transmittance values in spectral regions above and below those used in 1970. The spectral regions chosen were 450 nm, 550 nm, 650 nm and 800 nm. Comparisons of transmittance are made with the previous values, and new transmittance values are given.

  20. Absolute Efficiency Calibration of a Beta-Gamma Detector

    SciTech Connect (OSTI)

    Cooper, Matthew W.; Ely, James H.; Haas, Derek A.; Hayes, James C.; McIntyre, Justin I.; Lidey, Lance S.; Schrom, Brian T.

    2013-04-10

    Abstract- Identification and quantification of nuclear events such as the Fukushima reactor failure and nuclear explosions rely heavily on the accurate measurement of radioxenon releases. One radioxenon detection method depends on detecting beta-gamma coincident events paired with a stable xenon measurement to determine the concentration of a plume. Like all measurements, the beta-gamma method relies on knowing the detection efficiency for each isotope measured. Several methods are commonly used to characterize the detection efficiency for a beta-gamma detector. The most common method is using a NIST certified sealed source to determine the efficiency. A second method determines the detection efficiencies relative to an already characterized detector. Finally, a potentially more accurate method is to use the expected sample to perform an absolute efficiency calibration; in the case of a beta-gamma detector, this relies on radioxenon gas samples. The complication of the first method is it focuses only on the gamma detectors and does not offer a solution for determining the beta efficiency. The second method listed is not similarly constrained, however it relies on another detector to have a well-known efficiency calibration. The final method using actual radioxenon samples to make an absolute efficiency determination is the most desirable, but until recently it was not possible to produce all four isotopically pure radioxenon. The production, by University of Texas (UT), of isotopically pure radioxenon has allowed the beta-gamma detectors to be calibrated using the absolute efficiency method. The first four radioxenon isotope calibration will be discussed is this paper.

  1. Two-port microwave calibration at millikelvin temperatures

    SciTech Connect (OSTI)

    Ranzani, Leonardo; Spietz, Lafe; Aumentado, Jose [National Institute of Standards and Technology, Boulder, Colorado 80305 (United States); Popovic, Zoya [University of Colorado at Boulder, Boulder, Colorado 80309 (United States)

    2013-03-15

    In this work we introduce a system for 2-port microwave calibration at millikelvin temperatures operating at the coldest stage of a dilution refrigerator by use of an adapted thru-reflect-line algorithm. We show that this can be an effective tool for characterizing common 50 {Omega} microwave components with better than 0.1 dB accuracy at temperatures that are relevant to many current experiments in superconducting quantum information.

  2. Single View Point Omnidirectional Camera Calibration from Planar Grids

    E-Print Network [OSTI]

    Mei, Christopher

    to the approach comes from the precision reported, that is well adapted to outlier rejection (RANSAC) but less four F R2,T2 R1,T1 Rw,Tw Grid telecentric camera lens Mirror : a,b (or p) principal point, distortion distortion Camera skewness lens Fig. 1. Complete calibration pa- rameters F Grid Rw,Tw Mirror : a,b (or p

  3. MINOS Calibration and NA49 Hadronic Production Studies

    SciTech Connect (OSTI)

    Morse, Robert James

    2003-08-01

    An overview of the current status of the Main Injector Neutrino Oscillation Search (MINOS) is presented. MINOS is a long-baseline experiment with two detectors situated in North America. The near detector is based at the emission point of the NuMI beam at Fermilab, Chicago, the far detector is 735 km downstream in a disused iron mine in Soudan, Minnesota. A third detector, the calibration detector, is used to cross-calibrate these detectors by sampling different particle beams at CERN. A detailed description of the design and construction of the light-injection calibration system is included. Also presented are experimental investigations into proton-carbon collisions at 158 GeV/c carried out with the NA49 experiment at CERN. The NA49 experiment is a Time Projection Chamber (TPC) based experiment situated at CERN's North Area. It is a well established experiment with well known characteristics. The data gained from this investigation are to be used to parameterize various hadronic production processes in accelerator and atmospheric neutrino production. These hadronic production parameters will be used to improve the neutrino generation models used in calculating the neutrino oscillation parameters in MINOS.

  4. The Swift-UVOT ultraviolet and visible grism calibration

    E-Print Network [OSTI]

    Kuin, N P M; Breeveld, A A; Page, M J; James, C; Lamoureux, H; Mehdipour, M; Still, M; Yershov, V; Brown, P J; Carter, M; Mason, K O; Kennedy, T; Marshall, F; Roming, P W A; Siegel, M; Oates, S; Smith, P J; De Pasquale, M

    2015-01-01

    We present the calibration of the Swift UVOT grisms, of which there are two, providing low-resolution field spectroscopy in the ultraviolet and optical bands respectively. The UV grism covers the range 1700-5000 Angstrom with a spectral resolution of 75 at 2600 Angstrom for source magnitudes of u=10-16 mag, while the visible grism covers the range 2850-6600 Angstrom with a spectral resolution of 100 at 4000 Angstrom for source magnitudes of b=12-17 mag. This calibration extends over all detector positions, for all modes used during operations. The wavelength accuracy (1-sigma) is 9 Angstrom in the UV grism clocked mode, 17 Angstrom in the UV grism nominal mode and 22 Angstrom in the visible grism. The range below 2740 Angstrom in the UV grism and 5200 Angstrom in the visible grism never suffers from overlapping by higher spectral orders. The flux calibration of the grisms includes a correction we developed for coincidence loss in the detector. The error in the coincidence loss correction is less than 20%. The...

  5. Design of Experiments, Model Calibration and Data Assimilation

    SciTech Connect (OSTI)

    Williams, Brian J.

    2014-07-30

    This presentation provides an overview of emulation, calibration and experiment design for computer experiments. Emulation refers to building a statistical surrogate from a carefully selected and limited set of model runs to predict unsampled outputs. The standard kriging approach to emulation of complex computer models is presented. Calibration refers to the process of probabilistically constraining uncertain physics/engineering model inputs to be consistent with observed experimental data. An initial probability distribution for these parameters is updated using the experimental information. Markov chain Monte Carlo (MCMC) algorithms are often used to sample the calibrated parameter distribution. Several MCMC algorithms commonly employed in practice are presented, along with a popular diagnostic for evaluating chain behavior. Space-filling approaches to experiment design for selecting model runs to build effective emulators are discussed, including Latin Hypercube Design and extensions based on orthogonal array skeleton designs and imposed symmetry requirements. Optimization criteria that further enforce space-filling, possibly in projections of the input space, are mentioned. Designs to screen for important input variations are summarized and used for variable selection in a nuclear fuels performance application. This is followed by illustration of sequential experiment design strategies for optimization, global prediction, and rare event inference.

  6. An accurate continuous calibration system for high voltage current transformer

    SciTech Connect (OSTI)

    Tong Yue; Li Binhong [College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, Hubei Province (China)

    2011-02-15

    A continuous calibration system for high voltage current transformers is presented in this paper. The sensor of this system is based on a kind of electronic instrument current transformer, which is a clamp-shape air core coil. This system uses an optical fiber transmission system for its signal transmission and power supply. Finally the digital integrator and fourth-order convolution window algorithm as error calculation methods are realized by the virtual instrument with a personal computer. It is found that this system can calibrate a high voltage current transformer while energized, which means avoiding a long calibrating period in the power system and the loss of power metering expense. At the same time, it has a wide dynamic range and frequency band, and it can achieve a high accuracy measurement in a complex electromagnetic field environment. The experimental results and the on-site operation results presented in the last part of the paper, prove that it can reach the 0.05 accuracy class and is easy to operate on site.

  7. Annual Review of BPA-Funded Projects in Natural and Artificial Propagation of Salmonids, March 27-29, 1985, Holiday Inn Airport, Portland, Oregon.

    SciTech Connect (OSTI)

    United States. Bonneville Power Administration.

    1985-04-01

    The Fish and Wildlife Division of Bonneville Power Administration (BPA) hosted a meeting for contractors to present the results of fiscal year 1984 research conducted to implement the Northwest Power Planning Council's Fish and Wildlife Program. The meeting focused on those projects specifically related to natural and artificial propagation of salmonids. The presentations were held at the Holiday Inn Airport in Portland, Oregon, on March 27-29, 1985. This document contains abstracts of the presentations from that meeting. Section 1 contains abstracts on artificial propagation, fish health, and downstream migration, and Section 2 contains abstracts on natural propagation and habitat improvement. The abstracts are indexed by BPA Project Number and by Fish and Wildlife Program Measure. The registered attendees at the meeting are listed alphabetically in Appendix A and by affiliation in Appendix B.

  8. Corrective Action Decision Document/Closure Report for Corrective Action Unit 559: T Tunnel Compressor/Blower Pad, Nevada Test Site

    SciTech Connect (OSTI)

    NSTec Environmental Restoration

    2010-03-15

    This Corrective Action Decision Document (CADD)/Closure Report (CR) was prepared by the Defense Threat Reduction Agency (DTRA) for Corrective Action Unit (CAU) 559, T-Tunnel Compressor/Blower Pad. This CADD/CR is consistent with the requirements of the Federal Facility Agreement and Consent Order (FFACO) agreed to by the State of Nevada, the U.S. Department of Energy, and the U.S. Department of Defense. Corrective Action Unit 559 is comprised of one Corrective Action Site (CAS): • 12-25-13, Oil Stained Soil and Concrete The purpose of this CADD/CR is to provide justification and documentation supporting the recommendation for closure in place with use restrictions for CAU 559.

  9. Apparatus and method for field calibration of nuclear surface density gauges

    SciTech Connect (OSTI)

    Regimand, A.; Gilbert, A.B.

    1999-07-01

    Nuclear gauge density measurements are routinely used for compliance verification with specifications for road and construction projects. The density of construction materials is an important indicator of structural performance and quality. Due to speed of measurement, flexibility and accuracy, nuclear gauge density measurement methods are becoming the preferred standard around the world. Requirements dictate that gauges be verified or calibrated once every 12 to 18 months. Presently, there are no field portable devices available for verification of the gauge calibration. Also, the density references used for calibration of gauges, are large and not designed for field portability. Therefore, to meet the present standards, users are required to ship gauges back to a service facility for calibration. This paper presents results obtained by a newly developed device for field verification and calibration of nuclear density gauges from three different manufacturers. The calibrations obtained by this device are compared to the factory calibration methods and accuracies are reported for each gauge model.

  10. Risk assessment of the retrieval of transuranic waste: Pads 1, 2, and 4, Technical Area-54, Area G, Los Alamos National Laboratory

    SciTech Connect (OSTI)

    Wilbert, K.A.; Lyon, B.F.; Hutchison, J.; Holmes, J.A.; Legg, J.L.; Simek, M.P.; Travis, C.C.; Wollert, D.A.

    1995-05-01

    The Risk Assessment for the Retrieval of Transuranic Waste is a comparative risk assessment of the potential adverse human health effects resulting from exposure to contaminants during retrieval and post-retrieval aboveground storage operations of post-1970 earthen-covered transuranic waste. Two alternatives are compared: (1) Immediate Retrieval and (2) Delayed Retrieval. Under the Immediate Retrieval Alternative, retrieval of the waste is assumed to begin immediately, Under the Delayed Retrieval Alternative, retrieval is delayed 10 years. The current risk assessment is on Pads 1, 2, and 4, at Technical Area-54, Area-G, Los Alamos National Laboratory (LANL). Risks are assessed independently for three scenarios: (1) incident-free retrieval operations, (2) incident-free storage operations, and (3) a drum failure analysis. The drum failure analysis evaluates container integrity under both alternatives and assesses the impacts of potential drum failures during retrieval operations. Risks associated with a series of drum failures are potentially severe for workers, off-site receptors, and general on-site employees if retrieval is delayed 10 years and administrative and engineering controls remain constant. Under the Delayed Retrieval Alternative, an average of 300 drums out of 16,647 are estimated to fail during retrieval operations due to general corrosion, while minimal drums are predicted to fail under the Immediate Retrieval Alternative. The results of the current study suggest that, based on risk, remediation of Pads 1, 2, and 4 at LANL should not be delayed. Although risks from incident-free operations in the Delayed Retrieval Alternative are low, risks due to corrosion and drum failures are potentially severe.

  11. Adapting and calibration of existing wake models to meet the conditions inside offshore wind farms. Page 1 Adapting and calibration of existing wake models

    E-Print Network [OSTI]

    Adapting and calibration of existing wake models to meet the conditions inside offshore wind farms@emd.dk #12;Adapting and calibration of existing wake models to meet the conditions inside offshore wind farms inside offshore wind farms" has as purpose to improve the existing PARK models for calculating the wake

  12. Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. Calibrated Probabilistic Mesoscale Weather Field Forecasting: The Geostatist...

    E-Print Network [OSTI]

    Raftery, Adrian

    permission. Calibrated Probabilistic Mesoscale Weather Field Forecasting: The Geostatist... Yulia Gel; Adrian

  13. The M8 Power Calibration Experiment (M8CAL)

    SciTech Connect (OSTI)

    Robinson, W. R.; Bauer, T. H.

    1994-05-01

    The M8 calibration experiment was a series of 23 irradiations in TREAT performed to determine the relationship between the fission power generated in the TREAT core and the fission power generated in experiment fuel located in an in-core experiment vehicle and irradiated by core neutrons. The experiment was planned to provide the essential calibration information specifically needed for planning and analysis of the M8 test (and subsequent tests similar in geometry to M8) to be performed in the post-upgrade TREAT core. Irradiations were performed in TREAT cores loaded with a full-slotted (to optimize hodoscope performance) and with a half-slotted (to maximize energy deposition). Tests included a few selected low-power irradiations of fresh IFR-type U-Zr and U-Pu-Zr fuel pins supplemented by multiple irradiations of uranium-zirconium monitor wires ranging from low steady-state power to high-power maximal transients. This report describes the M8CAL test hardware, measurements, analysis assumptions, and methods used to deduce power coupling between the reactor and experiment fuel--including both absolute magnitudes and axial distributions. Power coupling results are reported for fresh IF fuel pins under high-power transient test conditions appropriate to the planned M8 transient test. In line with previous calibration data, measured dependence of power coupling on the specifics of each irradiation is also shown to correlate well with the in-core axial locations of the TREAT control rods. Estimates are made for maximal test fuel energy deposition capabilty in controlled transients.

  14. AMS Ground Truth Measurements: Calibration and Test Lines

    SciTech Connect (OSTI)

    Wasiolek, P.

    2013-11-01

    Airborne gamma spectrometry is one of the primary techniques used to define the extent of ground contamination after a radiological incident. Its usefulness was demonstrated extensively during the response to the Fukushima nuclear power plant (NPP) accident in March-May 2011. To map ground contamination a set of scintillation detectors is mounted on an airborne platform (airplane or helicopter) and flown over contaminated areas. The acquisition system collects spectral information together with the aircraft position and altitude every second. To provide useful information to decision makers, the count rate data expressed in counts per second (cps) needs to be converted to the terrestrial component of the exposure rate 1 m above ground, or surface activity of isotopes of concern. This is done using conversion coefficients derived from calibration flights. During a large scale radiological event, multiple flights may be necessary and may require use of assets from different agencies. However, as the production of a single, consistent map product depicting the ground contamination is the primary goal, it is critical to establish very early into the event a common calibration line. Such a line should be flown periodically in order to normalize data collected from different aerial acquisition systems and potentially flown at different flight altitudes and speeds. In order to verify and validate individual aerial systems, the calibration line needs to be characterized in terms of ground truth measurements. This is especially important if the contamination is due to short-lived radionuclides. The process of establishing such a line, as well as necessary ground truth measurements, is described in this document.

  15. Precession of the Equinoxes and the Calibration of Astronomical Epochs

    E-Print Network [OSTI]

    Burra G. Sidharth

    2011-02-03

    Astronomical observations were used as a marker for time and the Calendar from ancient times. A more subtle calibration of epochs is thrown up by an observation of the position of the solstices and equinoxes, because these points shift in the sky with the years resulting in the gradual shift of celestial longitudes $\\lambda$. Chronology based on such observations however needs to be backed up by hard evidence. We match both to take us back to $10,000$ B.C., the epi-paleolithic period, and the beginning of civilization itself.

  16. Precession of the Equinoxes and the Calibration of Astronomical Epochs

    E-Print Network [OSTI]

    Sidharth, Burra G

    2010-01-01

    Astronomical observations were used as a marker for time and the Calendar from ancient times. A more subtle calibration of epochs is thrown up by an observation of the position of the solstices and equinoxes, because these points shift in the sky with the years resulting in the gradual shift of celestial longitudes $\\lambda$. Chronology based on such observations however needs to be backed up by hard evidence. We match both to take us back to $10,000$ B.C., the epi-paleolithic period, and the beginning of civilization itself.

  17. Calibration and Measurement Uncertainty Estimation of Radiometric Data: Preprint

    SciTech Connect (OSTI)

    Habte, A.; Sengupta, M.; Reda, I.; Andreas, A.; Konings, J.

    2014-11-01

    Evaluating the performance of photovoltaic cells, modules, and arrays that form large solar deployments relies on accurate measurements of the available solar resource. Therefore, determining the accuracy of these solar radiation measurements provides a better understanding of investment risks. This paper provides guidelines and recommended procedures for estimating the uncertainty in calibrations and measurements by radiometers using methods that follow the International Bureau of Weights and Measures Guide to the Expression of Uncertainty (GUM). Standardized analysis based on these procedures ensures that the uncertainty quoted is well documented.

  18. An Improved Procedure for Developing Calibrated Hourly Simulation Models 

    E-Print Network [OSTI]

    Bou-Saada, T. E.; Haberl, J. S.

    1995-01-01

    . REFERENCES Abbas, M. 1993. Development of graphical indices for building energy data, M.S. Thesis, Energy Systems Rpt No. ESL-TH-93/12-02, Texas A&M University, College Station, TX. ASHRAE. 1991. ASHRAE handbook: 1991 HVAC applications volume. American... Support Office, University of Illinois Urbana-Champaign. Bou-Saada, T.E. 1994a. An improved procedure for developing a calibrated hourly simulation model of an electrically heated and cooled commercial building, M.S. Thesis, Energy Systems Rpt No. ESL- TH...

  19. Residential Vertical Geothermal Heat Pump System Models: Calibration to Data:

    SciTech Connect (OSTI)

    Thornton, Jeff W.; McDowell, T. P.; Shonder, John A; Hughes, Patrick; Pahud, D.; Hellstrom, G.

    1997-06-01

    A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.

  20. Residential vertical geothermal heat pump system models: Calibration to data

    SciTech Connect (OSTI)

    Thornton, J.W.; McDowell, T.P.; Shonder, J.A.; Hughes, P.J.; Pahud, D.; Hellstroem, G.A.J.

    1997-12-31

    A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.

  1. Active radiometer for self-calibrated furnace temperature measurements

    DOE Patents [OSTI]

    Woskov, Paul P. (Bedford, MA); Cohn, Daniel R. (Chestnut Hill, MA); Titus, Charles H. (Newtown Square, PA); Wittle, J. Kenneth (Chester Springs, PA); Surma, Jeffrey E. (Kennewick, WA)

    1996-01-01

    Radiometer with a probe beam superimposed on its field-of-view for furnace temperature measurements. The radiometer includes a heterodyne millimeter/submillimeter-wave receiver including a millimeter/submillimeter-wave source for probing. The receiver is adapted to receive radiation from a surface whose temperature is to be measured. The radiation includes a surface emission portion and a surface reflection portion which includes the probe beam energy reflected from the surface. The surface emission portion is related to the surface temperature and the surface reflection portion is related to the emissivity of the surface. The simultaneous measurement of surface emissivity serves as a real time calibration of the temperature measurement.

  2. Calibrating Building Energy Models Using Supercomputer Trained Machine Learning Agents

    SciTech Connect (OSTI)

    Sanyal, Jibonananda [ORNL] [ORNL; New, Joshua Ryan [ORNL] [ORNL; Edwards, Richard [ORNL] [ORNL; Parker, Lynne Edwards [ORNL] [ORNL

    2014-01-01

    Building Energy Modeling (BEM) is an approach to model the energy usage in buildings for design and retrofit purposes. EnergyPlus is the flagship Department of Energy software that performs BEM for different types of buildings. The input to EnergyPlus can often extend in the order of a few thousand parameters which have to be calibrated manually by an expert for realistic energy modeling. This makes it challenging and expensive thereby making building energy modeling unfeasible for smaller projects. In this paper, we describe the Autotune research which employs machine learning algorithms to generate agents for the different kinds of standard reference buildings in the U.S. building stock. The parametric space and the variety of building locations and types make this a challenging computational problem necessitating the use of supercomputers. Millions of EnergyPlus simulations are run on supercomputers which are subsequently used to train machine learning algorithms to generate agents. These agents, once created, can then run in a fraction of the time thereby allowing cost-effective calibration of building models.

  3. Sensor development and calibration for acoustic neutrino detection in ice

    E-Print Network [OSTI]

    Karg, Timo; Laihem, Karim; Semburg, Benjamin; Tosi, Delia

    2009-01-01

    A promising approach to measure the expected low flux of cosmic neutrinos at the highest energies (E > 1 EeV) is acoustic detection. There are different in-situ test installations worldwide in water and ice to measure the acoustic properties of the medium with regard to the feasibility of acoustic neutrino detection. The parameters of interest include attenuation length, sound speed profile, background noise level and transient backgrounds. The South Pole Acoustic Test Setup (SPATS) has been deployed in the upper 500 m of drill holes for the IceCube neutrino observatory at the geographic South Pole. In-situ calibration of sensors under the combined influence of low temperature, high ambient pressure, and ice-sensor acoustic coupling is difficult. We discuss laboratory calibrations in water and ice. Two new laboratory facilities, the Aachen Acoustic Laboratory (AAL) and the Wuppertal Water Tank Test Facility, have been set up. They offer large volumes of bubble free ice (3 m^3) and water (11 m^3) for the devel...

  4. The Calibration of the PEPPo Polarimeter for Electrons and Positrons

    SciTech Connect (OSTI)

    Adeyemi, Adeleke Hakeem [Hampton University, Hampton, VA (United States); Voutier, Eric J-.M. [Laboratoire de Physique Subatomique et Cosmologie, Grenoble (France)

    2013-06-01

    The PEPPo (Polarized Electrons for Polarized Positrons) experiment at Jefferson Laboratory investigated the polarization transfer from longitudinally polarized electrons to longitudinally polarized positrons, with the aim of developing this technology for a low energy (~MeV) polarized positron source. Polarization of the positrons was measured by means of a Compton transmission polarimeter where incoming positrons transfer their polarization into circularly polarized photons that were subsequently analyzed by a thick polarized iron target. The measurement of the transmitted photon flux with respect to the orientation of the target polarization (+-) or the helicity (+-) of the incoming leptons provided the measurement of their polarization. Similar measurements with a known electron beam were also performed for calibration purposes. This presentation will describe the apparatus and calibrations performed at the injector at the Jefferson Laboratory to measure positron polarization in the momentum range 3.2-6.2 MeV/c, specifically to quantify the positron analyzing power from electron experimental data measured over a comparable momentum range.

  5. Calibration of bremsstrahlung prefogged Kodak RAR 2492 film

    SciTech Connect (OSTI)

    Gorzen, D.F.; Armentrout, C.; Burek, A.; Bird, R.; Geddes, J.; Gerber, G. (KMS Fusion, Inc., Ann Arbor, MI (USA)); Rockett, P.D. (Sandia National Laboratory, Albuquerque, NM (USA))

    1990-10-01

    High-energy background radiation from PBFA II at Sandia National Laboratory introduces uncertainty regarding the effect of background fogging on the sensitivity of the x-ray film at soft x-ray energies. We have performed a calibration to determine how the sensitivity of the Kodak RAR 2492 film is affected by high-energy background radiation. To simulate the background radiation the film was fogged to various densities using a 10 keV bremsstrahlung spectrum. The film was then exposed to soft x-ray emission lines of Al {ital K}{alpha} and Ti {ital K}{alpha} selected by Bragg reflection from an electron bombardment source. The intensity of the x-ray flux was continuously monitored with a Si(Li) detector to eliminate error due to drift of the x-ray source's intensity. A microdensitometer with matched objectives was used to find the specular density of the exposed film. The results of the calibration are presented in the form of {ital D} vs log {ital l} for the various densities of the bremmstrahlung prefog exposures.

  6. Calibration and Characterization of the IceCube Photomultiplier Tube

    SciTech Connect (OSTI)

    IceCube Collaboration; Abbasi, R.; al., et

    2010-02-11

    Over 5,000 PMTs are being deployed at the South Pole to compose the IceCube neutrino observatory. Many are placed deep in the ice to detect Cherenkov light emitted by the products of high-energy neutrino interactions, and others are frozen into tanks on the surface to detect particles from atmospheric cosmic ray showers. IceCube is using the 10-inch diameter R7081-02 made by Hamamatsu Photonics. This paper describes the laboratory characterization and calibration of these PMTs before deployment. PMTs were illuminated with pulses ranging from single photons to saturation level. Parameterizations are given for the single photoelectron charge spectrum and the saturation behavior. Time resolution, late pulses and afterpulses are characterized. Because the PMTs are relatively large, the cathode sensitivity uniformity was measured. The absolute photon detection efficiency was calibrated using Rayleigh-scattered photons from a nitrogen laser. Measured characteristics are discussed in the context of their relevance to IceCube event reconstruction and simulation efforts.

  7. Halo Luminosity Function From Photometric Calibration of the Revised NLTT

    E-Print Network [OSTI]

    Andrew Gould; Juna A. Kollmeier; Julio Chaname; Samir Salim

    2004-12-30

    We calibrate the photographic photometry of the revised New Luyten Two-Tenths catalog (rNLTT) by matching 3448 rNLTT stars to the Sloan Digital Sky Survey (SDSS). The correction is linear in magnitude and goes from zero at V ~ 14 to 0.32 mag at V=19, in the sense that rNLTT was previously too bright. The correction implies that the underlying USNO-A2.0 photometry, on which rNLTT photometry is based, is non-linear. The new calibration somewhat improves the appearance of the (V,V-J) reduced proper motion diagram in the sense of better separation between disk and halo stars. We repeat Gould's analysis of 5000 halo stars in rNLTT. The most important change is to move the peak of the halo luminosity function about 0.5 mag dimmer, from M_V=10.5 to M_V=11, putting it into good agreement with the parallax-based determination of Dahn et al.

  8. A method for the extrapolation of calibration data of PTC 6 throat tap nozzles

    SciTech Connect (OSTI)

    Murdock, J.W. (Drexel Univ., Philadelphia, PA (USA)); Keyser, D.R. (Naval Air Development Center, Warminster, PA (USA))

    1990-01-01

    This paper describes a precise method for extrapolating the coefficient of discharge of PTC 6 throat tap nozzles using all or most of the calibration data. Numerical examples are given using actual calibration data to describe this method. Because this method permits the use of all calibration data at or above Reynolds numbers of 1,000,000 it is a clear improvement over the PTC 6 -1976 method which permits only the highest single point.

  9. Generator Dynamic Model Validation and Parameter Calibration Using Phasor Measurements at the Point of Connection

    SciTech Connect (OSTI)

    Huang, Zhenyu; Du, Pengwei; Kosterev, Dmitry; Yang, Steve

    2013-05-01

    Disturbance data recorded by phasor measurement units (PMU) offers opportunities to improve the integrity of dynamic models. However, manually tuning parameters through play-back events demands significant efforts and engineering experiences. In this paper, a calibration method using the extended Kalman filter (EKF) technique is proposed. The formulation of EKF with parameter calibration is discussed. Case studies are presented to demonstrate its validity. The proposed calibration method is cost-effective, complementary to traditional equipment testing for improving dynamic model quality.

  10. UNIVERSAL AUTO-CALIBRATION FOR A RAPID BATTERY IMPEDANCE SPECTRUM MEASUREMENT DEVICE

    SciTech Connect (OSTI)

    Jon P. Christophersen; John L. Morrison; William H. Morrison

    2014-03-01

    Electrochemical impedance spectroscopy has been shown to be a valuable tool for diagnostics and prognostics of energy storage devices such as batteries and ultra-capacitors. Although measurements have been typically confined to laboratory environments, rapid impedance spectrum measurement techniques have been developed for on-line, embedded applications as well. The prototype hardware for the rapid technique has been validated using lithium-ion batteries, but issues with calibration had also been identified. A new, universal automatic calibration technique was developed to address the identified issues while also enabling a more simplified approach. A single, broad-frequency range is used to calibrate the system and then scaled to the actual range and conditions used when measuring a device under test. The range used for calibration must be broad relative to the expected measurement conditions for the scaling to be successful. Validation studies were performed by comparing the universal calibration approach with data acquired from targeted calibration ranges based on the expected range of performance for the device under test. First, a mid-level shunt range was used for calibration and used to measure devices with lower and higher impedance. Next, a high excitation current level was used for calibration, followed by measurements using lower currents. Finally, calibration was performed over a wide frequency range and used to measure test articles with a lower set of frequencies. In all cases, the universal calibration approach compared very well with results acquired following a targeted calibration. Additionally, the shunts used for the automated calibration technique were successfully characterized such that the rapid impedance measurements compare very well with laboratory-scale measurements. These data indicate that the universal approach can be successfully used for onboard rapid impedance spectra measurements for a broad set of test devices and range of measurement conditions.

  11. Long Time Stability of the Energy Scale Calibration of a Quantum 2000

    E-Print Network [OSTI]

    Scheithauer, Uwe

    2015-01-01

    According to the international standard ISO 15472 the energy scale of an XPS instrument, type Physical Electronics Quantum 2000, was calibrated. It is shown, how the procedures of the ISO 15472 were adapted to the hardware and software design of the Quantum 2000. The long time stability of the energy scale calibration of the XPS instrument was investigated. The instrumented was operated with a satisfying energy scale calibration over a period of 8 years. All the time energy differences between certain peaks could be measured with the chosen precision of the energy scale calibration.

  12. A Fast Calibration System for SiPM Based Scintillator HCAL Detector

    E-Print Network [OSTI]

    Polak, I

    2015-01-01

    We report on latest version of the calibration and monitoring system developed for the scintillator tile hadroncalorimeter (AHCAL) for the ILC. System is based on original fast

  13. A Workflow for Parameter Calibration and and Model Validation in SST: Interim Report.

    SciTech Connect (OSTI)

    Pebay, Philippe Pierre; Wilke, Jeremiah J; Sargsyan, Khachik

    2014-12-01

    This brief report explains the method used for parameter calibration and model validation in SST/Macro and the set of tools and workflow developed for this purpose.

  14. Extending vaterite microviscometry to ex vivo blood vessels by serial calibration

    E-Print Network [OSTI]

    Shreim, Samir G.; Steward, Earl; Botvinick, Elliot L.

    2011-01-01

    stresses doing in our blood vessels? ” Ann. Biomed. Eng. 19(to ex vivo blood vessels by serial calibration Samir G.implications in vessel mechanics and mechanotransduction.

  15. Instructions for calibrating gamma detectors using the Canberra-Nuclear Data Genie Gamma Spectroscopy System

    SciTech Connect (OSTI)

    Brunk, J.L.

    1995-09-01

    A straight forward protocol provides a way to guide the calibration of a gamma detector for a particular geometry and material. Several programs have used the Low Level Gamma Counting Facility of the Health and Ecological Assessment Division of the Lawrence Livermore National Laboratory to count a variety of large environmental samples contained in several unique geometries. The equipment and calibration requirements needed to analyze these types of samples are explained. This document describes the calibration protocol that has been developed and describes how it is used to calibrate the detectors.

  16. A Local Ensemble Prediction System for Fog and Low Clouds: Construction, Bayesian Model Averaging Calibration, and Validation

    E-Print Network [OSTI]

    A Local Ensemble Prediction System for Fog and Low Clouds: Construction, Bayesian Model Averaging. Meteorologists face the challenge of supplying airport authorities with accurate forecasts of fog and cloud during their life cycle. To obtain accurate forecasts of fog and low clouds, the Code de Brouillard à l

  17. The Laser Calibration System of the ALICE Time Projection Chamber

    E-Print Network [OSTI]

    G. Renault; B. S. Nielsen; J. Westergaard; J. J. Gaardhøje

    2005-11-07

    A Large Ion Collider Experiment (ALICE) is the only experiment at the Large Hadron Collider (LHC) dedicated to the study of heavy ion collisions. The Time Projection Chamber (TPC) is the main tracking detector covering the pseudo rapidity range $|\\eta|laser system is to simulate ionizing tracks at predifined positions throughout the drift volume in order to monitor the TPC response to a known source. In particular, the alignment of the read-out chambers will be performed, and variations of the drift velocity due to drift field imperfections can be measured and used as calibration data in the physics data analysis. In this paper we present the design of the pulsed UV laser and optical system, together with the control and monitoring systems.

  18. Calibrating the Abaqus Crushable Foam Material Model using UNM Data

    SciTech Connect (OSTI)

    Schembri, Philip E.; Lewis, Matthew W.

    2014-02-27

    Triaxial test data from the University of New Mexico and uniaxial test data from W-14 is used to calibrate the Abaqus crushable foam material model to represent the syntactic foam comprised of APO-BMI matrix and carbon microballoons used in the W76. The material model is an elasto-plasticity model in which the yield strength depends on pressure. Both the elastic properties and the yield stress are estimated by fitting a line to the elastic region of each test response. The model parameters are fit to the data (in a non-rigorous way) to provide both a conservative and not-conservative material model. The model is verified to perform as intended by comparing the values of pressure and shear stress at yield, as well as the shear and volumetric stress-strain response, to the test data.

  19. THE ABSOLUTE CALIBRATION OF THE EUV IMAGING SPECTROMETER ON HINODE

    SciTech Connect (OSTI)

    Warren, Harry P.; Ugarte-Urra, Ignacio; Landi, Enrico

    2014-07-01

    We investigate the absolute calibration of the EUV Imaging Spectrometer (EIS) on Hinode by comparing EIS full-disk mosaics with irradiance observations from the EUV Variability Experiment on the Solar Dynamics Observatory. We also use extended observations of the quiet corona above the limb combined with a simple differential emission measure model to establish new effective area curves that incorporate information from the most recent atomic physics calculations. We find that changes to the EIS instrument sensitivity are a complex function of both time and wavelength. We find that the sensitivity is decaying exponentially with time and that the decay constants vary with wavelength. The EIS short wavelength channel shows significantly longer decay times than the long wavelength channel.

  20. Management of vacuum leak-detection processes, standards, and calibration

    SciTech Connect (OSTI)

    Wilson, N.G.

    1984-01-01

    Vacuum leak detection requires integrated management action to ensure the successful production of apparatus having required leak tightness. Implementation of properly planned, scheduled, and engineering procedures and test arrangements are an absolute necessity to prevent unexpected, impractical, technically inadequate, or unnecessarily costly incidents in leak-testing operations. The use of standard procedures, leak standards appropriate to the task, and accurate calibration systems or devices is necessary to validate the integrity of any leak-test procedure. In this paper, the need for implementing these practices is discussed using case histories of typical examples of large complex vacuum systems. Aggressive management practices are of primary importance throughout a project's life cycle to ensure the lowest cost; this includes successful leak testing of components. It should be noted that the opinions and conclusions expressed in this paper are those of the author and are not those of the Los Alamos National Laboratory or the Department of Energy.

  1. Active radiometer for self-calibrated furnace temperature measurements

    DOE Patents [OSTI]

    Woskov, P.P.; Cohn, D.R.; Titus, C.H.; Wittle, J.K.; Surma, J.E.

    1996-11-12

    A radiometer is described with a probe beam superimposed on its field-of-view for furnace temperature measurements. The radiometer includes a heterodyne millimeter/submillimeter-wave receiver including a millimeter/submillimeter-wave source for probing. The receiver is adapted to receive radiation from a surface whose temperature is to be measured. The radiation includes a surface emission portion and a surface reflection portion which includes the probe beam energy reflected from the surface. The surface emission portion is related to the surface temperature and the surface reflection portion is related to the emissivity of the surface. The simultaneous measurement of surface emissivity serves as a real time calibration of the temperature measurement. 5 figs.

  2. Bandpass calibration of a wideband spectrometer using pulse injection

    E-Print Network [OSTI]

    Patra, Nipanjana; Ekers, Ron; Roberts, Paul

    2015-01-01

    We present a novel time domain concept for determining the bandpass response of a system by injecting a nanosecond pulse and capturing the system voltage output. A pulse of sub-nanosecond duration contains all frequency components with constant amplitude up to 1~GHz. Hence, this method can accurately determine the system bandpass response to a broadband signal. A train of pulses are coherently accumulated providing very high signal-to-noise calibration. The basic concept is demonstrated using a pulse generator-accumulator setup realised in a Bedlam board which is a high speed digital signal processing unit. The same system was used at the Parkes Radio Telescope between 2--13 October 2013 and we demonstrate its powerful diagnostic capability. We also present some initial test data from this experiment.

  3. TA-55 Hot CMM Calibration Tolerance Analysis (U)

    SciTech Connect (OSTI)

    Montano, Joshua D. [Los Alamos National Laboratory

    2012-06-12

    The Hot Coordinate Measuring Machine (CMM), a Brown and Sharpe Xcel 765, has specifications listed by the manufacture of 4.5 + L/250 {micro}m for volumetric performance, 3.5 {micro}m for probing and 4.5 {micro}m for scanning. An upgrade was performed on the machine increasing its performance capability. This document reviews calibration data gathered after the upgrade over a five year period (2005-2010) and recommends a new specification of 3.0 + L/250 {micro}m for size, 3.3 {micro}m for probing, and 4.3 {micro}m for scanning. The new equations are an approximate 30% increase in accuracy for size and approximately 5% increase for probing and scanning.

  4. Asteroseismology and calibration of alpha Cen binary system

    E-Print Network [OSTI]

    Thévenin, F; Morel, P; Berthomieu, G; Bouchy, F; Carrier, F

    2002-01-01

    Using the oscillation frequencies of alpha Cen A recently discovered by Bouchy & Carrier, the available astrometric, photometric and spectroscopic data, we tried to improve the calibration of the visual binary system alpha Cen. With the revisited masses of Pourbaix et al. (2002) we do not succeed to obtain a solution satisfying all the seismic observational constraints. Relaxing the constraints on the masses, we have found an age t_alpha Cen=4850+-500 Myr, an initial helium mass fraction Y_i = 0.300+-0.008, and an initial metallicity (Z/X)_i=0.0459+-0.0019, with M_A=1.100+-0.006M_o and M_B=0.907+-0.006M_o for alpha Cen A&B.

  5. Asteroseismology and calibration of alpha Cen binary system

    E-Print Network [OSTI]

    F. Thevenin; J. Provost; P. Morel; G. Berthomieu; F. Bouchy; F. Carrier

    2002-06-17

    Using the oscillation frequencies of alpha Cen A recently discovered by Bouchy & Carrier, the available astrometric, photometric and spectroscopic data, we tried to improve the calibration of the visual binary system alpha Cen. With the revisited masses of Pourbaix et al. (2002) we do not succeed to obtain a solution satisfying all the seismic observational constraints. Relaxing the constraints on the masses, we have found an age t_alpha Cen=4850+-500 Myr, an initial helium mass fraction Y_i = 0.300+-0.008, and an initial metallicity (Z/X)_i=0.0459+-0.0019, with M_A=1.100+-0.006M_o and M_B=0.907+-0.006M_o for alpha Cen A&B.

  6. Spectral calibration in the mid-infrared: Challenges and solutions

    SciTech Connect (OSTI)

    Sloan, G. C. [Cornell University, Center for Radiophysics and Space Research, Ithaca, NY 14853-6801 (United States); Herter, T. L.; Houck, J. R. [Cornell University, Astronomy Department, Ithaca, NY 14853-6801 (United States); Charmandaris, V. [Department of Physics and ITCP, University of Crete, GR-71003, Heraklion (Greece); Sheth, K. [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903 (United States); Burgdorf, M., E-mail: sloan@isc.astro.cornell.edu [HE Space Operations, Flughafenallee 24, D-28199 Bremen (Germany)

    2015-01-01

    We present spectra obtained with the Infrared Spectrograph on the Spitzer Space Telescope of 33 K giants and 20 A dwarfs to assess their suitability as spectrophotometric standard stars. The K giants confirm previous findings that the strength of the SiO absorption band at 8 ?m increases for both later optical spectral classes and redder (B–V){sub 0} colors, but with considerable scatter. For K giants, the synthetic spectra underpredict the strengths of the molecular bands from SiO and OH. For these reasons, the assumed true spectra for K giants should be based on the assumption that molecular band strengths in the infrared can be predicted accurately from neither optical spectral class or color nor synthetric spectra. The OH bands in K giants grow stronger with cooler stellar temperatures, and they are stronger than predicted by synthetic spectra. As a group, A dwarfs are better behaved and more predictable than the K giants, but they are more likely to show red excesses from debris disks. No suitable A dwarfs were located in parts of the sky continuously observable from Spitzer, and with previous means of estimating the true spectra of K giants ruled out, it was necessary to use models of A dwarfs to calibrate spectra of K giants from observed spectral ratios of the two groups and then use the calibrated K giants as standards for the full database of infrared spectra from Spitzer. We also describe a lingering artifact that affects the spectra of faint blue sources at 24 ?m.

  7. Extending the Calibration of the ATLAS Hadronic Calorimeter to High Pt

    E-Print Network [OSTI]

    in 2007 will study pp collisions with energies of 7 TeV per beam. Many of the interesting physics studies will involve quark and gluon jets with energies of many TeV. To accurately measure such jets, the calorimeter must be calibrated over all energy ranges. This paper presents an overview of calibration techniques

  8. Behavior of Calibration Electrons in the Mu2e Tracking Chamber Devyn Shafera,b

    E-Print Network [OSTI]

    Gollin, George

    Behavior of Calibration Electrons in the Mu2e Tracking Chamber Devyn Shafera,b , George Gollina, University of Pennsylvania July 30, 2010 ABSTRACT The paper describes the simulation of calibration electrons and a description of methods of determining electron paths. The final objective of the project involves creating

  9. Supplementary details on Bayesian Calibration of Computer Marc C. Kennedy and Anthony O'Hagan

    E-Print Network [OSTI]

    O'Hagan, Tony

    Supplementary details on Bayesian Calibration of Computer Models Marc C. Kennedy and Anthony O in the Bayesian calibration methods of Kennedy and O'Hagan (2000), and we present a further example using data with the concepts and notation of Kennedy and O'Hagan (2000). We begin by deriving the posterior distribution

  10. A Configurable IC to Contol, Readout, and Calibrate an Array of Biosensors

    E-Print Network [OSTI]

    De Micheli, Giovanni

    A Configurable IC to Contol, Readout, and Calibrate an Array of Biosensors Sara S. Ghoreishizadeh bimolecular sensors as well as pH and temperature sensors for biosensor calibration. The IC supports both of the interface electronics, a unified circuit is designed for CV, CA and pH readout. The biosensors produce

  11. Calibration of a Parallel Robot Using Multiple Kinematic Closed Ali Nahvi, John M. Hollerbach

    E-Print Network [OSTI]

    Hollerbach, John M.

    ,he shoulder joint 2 Mechanism Kinematics The kinematic model is shown in Figure 2. A, (i=1,2,3,4) representsCalibration of a Parallel Robot Using Multiple Kinematic Closed Loops Ali Nahvi, John M. Hollerbach be kinematically calibrated using joint an- gle readings alone [l . By placement of the closed dit

  12. Calibration of Multi-Axis MEMS Force Sensors Using the Shape from Motion Method

    E-Print Network [OSTI]

    Sun, Yu

    Calibration of Multi-Axis MEMS Force Sensors Using the Shape from Motion Method Yu Sun, Keekyoung Inst. of Robotics and Intelligent Systems University of Toronto University of Minnesota Swiss Federal systems) capacitive force sensor with strict linearity and a new sensor calibration method for micro-sensors

  13. Calibration of Predicted Hourly Zone-Level Supply Air Flows with Measurements 

    E-Print Network [OSTI]

    Mihai, A.; Zmeureanu, R.

    2013-01-01

    The calibrated building energy models can be used for the verification and improvement of building operation. This paper proposes a bottom-up approach for the assisted calibration of a building energy model developed with eQuest program, and using...

  14. Gas Flowmeter Calibrations with the Working Gas Flow Standard NIST Special Publication 250-80

    E-Print Network [OSTI]

    Gas Flowmeter Calibrations with the Working Gas Flow Standard NIST Special Publication 250-80 John of Standards and Technology U. S. Department of Commerce #12;ii Table of Contents Gas Flowmeter Calibrations with the Working Gas Flow Standard .......................... i Abstract

  15. ON THE CALIBRATION OF SEISMIC ATTRIBUTES FOR RESERVOIR CHARACTERIZATION AND MONITORING

    E-Print Network [OSTI]

    ON THE CALIBRATION OF SEISMIC ATTRIBUTES FOR RESERVOIR CHARACTERIZATION AND MONITORING A brief, Colombia; ANASTASIA MINAEVA1 , Shell Exploration and Production Co., New Orleans, LA; SHAWN M. LEN1 , Ewen Technological University) In the DOE-sponsored project, "Calibration of Seismic Attributes for Reservoir

  16. On the antenna calibration of space radio instruments using the galactic background: General formulas

    E-Print Network [OSTI]

    California at Berkeley, University of

    and application to STEREO/WAVES, Radio Sci., 46, RS2008, doi:10.1029/2010RS004464. 1. Introduction [2] Radio apply these rela- tions to the antenna calibration of the STEREO/WAVES (S/WAVES) radio instrumentOn the antenna calibration of space radio instruments using the galactic background: General

  17. Calibration of the osmotic technique of controlling suction with respect to temperature using a miniature tensiometer

    E-Print Network [OSTI]

    Boyer, Edmond

    Calibration of the osmotic technique of controlling suction with respect to temperature using Geotechnical Journal 47 (2010) 359-365" #12;2 Abstract The osmotic technique was calibrated at various. Keywords: Suction control, osmotic technique, temperature effect, high-capacity tensiometer, poly

  18. Total Solar Irradiance Calibration Transfer Experiment/TIM Frequently Asked Questions

    E-Print Network [OSTI]

    Mojzsis, Stephen J.

    TCTE Total Solar Irradiance Calibration Transfer Experiment/TIM Frequently Asked Questions What is the purpose of the TCTE mission? The Total Solar Irradiance Calibration Transfer Experiment (TCTE to monitor changes in solar irradiance at the top of the Earth's atmosphere. TCTE will launch as one of five

  19. Multivariate calibration with single-index signal regression Paul H.C. Eilers a

    E-Print Network [OSTI]

    Marx, Brian D.

    February 2009 Keywords: Multivariate calibration P-splines Projection pursuit regression In general, linearity is assumed to hold in multivariate calibration, but this may not be true. Penalized signal. The higher-dimensional space is never explicitly constructed: it is implied by the kernel function. We

  20. Geological Calibration of Spallation Production Rates1 in the CRONUS-Earth Project2

    E-Print Network [OSTI]

    Borchers, Brian

    : cosmogenic nuclide, production rate, calibration, beryllium-10,28 aluminum-26, carbon-14, helium-3, chlorineGeological Calibration of Spallation Production Rates1 in the CRONUS-Earth Project2 Brian Borchersa. stone@ess.washington.edu26 Abstract27 Models of the production of cosmogenic nuclides typically

  1. 3D Pitot Tube Measurements and Calibration in the Wind Tunnel

    E-Print Network [OSTI]

    3D Pitot Tube Measurements and Calibration in the Wind Tunnel Center for Measurement Standards by CFD 9 #12;Copyright 2014 ITRI Omni-type 3D pitot tube Characterization of Pitot Tubes - Design of 3D.4) % · With grid No.4: T.I.= (1.7 to 4.4) % Grid-generated turbulent flow Calibration Facilities - Turbulence

  2. REVIEW OF SCIENTIFIC INSTRUMENTS 82, 033510 (2011) Calibrated cylindrical Mach probe in a plasma wind tunnel

    E-Print Network [OSTI]

    Brown, Michael R.

    2011-01-01

    wind tunnel X. Zhang,1,a) D. Dandurand,1 T. Gray,1 M. R. Brown,1 and V. S. Lukin2 1 Department probe is described along with an independent calibration procedure in a magnetized plasma wind tunnel calibration method based on magnetic time-of-flight in a magnetized wind tunnel is pre- sented and a particle

  3. Subwavenumber charge-coupled device spectrometer calibration using molecular iodine laser-induced fluorescence

    SciTech Connect (OSTI)

    Lambert, Joseph G. [Department of Physics, Drexel University, Philadelphia, Pennsylvania 19104 (United States); Hernandez-Diaz, Carlos; Williamson, J. Charles [Department of Chemistry, Willamette University, Salem, Oregon 97301 (United States)

    2010-01-15

    Spectrometers configured with charge-coupled devices (CCD) or other array-based detectors require calibration to convert from the pixel coordinate to a spectral coordinate. A CCD calibration method well suited for Raman spectroscopy has been developed based on the 514.5 nm Ar{sup +} laser-induced fluorescence (LIF) spectrum of room-temperature molecular iodine vapor. Over 360 primary and secondary I{sub 2} LIF calibration lines spanning 510-645 nm were identified as calibrant peaks using an instrumental resolution of 1 cm{sup -1}. Two instrument calibration functions were evaluated with these peaks: a second-order polynomial and a function derived from simple optomechanical considerations. The latter function provided better fitting characteristics. Calibration using I{sub 2} LIF was tested with measurements of both laser light scattering and Raman spectra. The I{sub 2} LIF reference spectra and the signal spectra were recorded simultaneously, with no cross talk, by separating the two signals spatially along the vertical axis of the CCD imager. In this way, every CCD image could be independently calibrated. An accuracy and a precision of {+-}0.05 cm{sup -1} were achieved with this calibration technique.

  4. Study of Calibration of Solar Radio Spectrometers and the quiet-Sun Radio Emission

    E-Print Network [OSTI]

    Tan, Chengming; Tan, Baolin; Fu, Qijun; Liu, Yuying; Xu, Guirong

    2015-01-01

    This work presents a systematic investigation of the influence of weather conditions on the calibration errors by using Gaussian fitness, least chi-square linear fitness and wavelet transform to analyze the calibration coefficients from observations of the Chinese Solar Broadband Radio Spectrometers (at frequency bands of 1.0-2.0 GHz, 2.6-3.8 GHz, and 5.2-7.6 GHz) during 1997-2007. We found that calibration coefficients are influenced by the local air temperature. Considering the temperature correction, the calibration error will reduce by about $10\\%-20\\%$ at 2800 MHz. Based on the above investigation and the calibration corrections, we further study the radio emission of the quiet-Sun by using an appropriate hybrid model of the quiet-Sun atmosphere. The results indicate that the numerical flux of the hybrid model is much closer to the observation flux than that of other ones.

  5. Extending and formalizing the energy signature method for calibrating simulations and illustrating with application for three California climates 

    E-Print Network [OSTI]

    Bensouda, Nabil

    2004-11-15

    for calibrated simulation in recent years (IPMVP 2001, Liu and Claridge 1998). They discussed potential uses for calibrated simulation, which include: ???? energy audits, to determine the potential savings from proposed retrofit measures; ???? energy...

  6. Determination of elemental impurities in plastic calibration standards using laser induced breakdown spectroscopy

    SciTech Connect (OSTI)

    McIntyre, D.; Ayyalasomayajula, K.; Jain, J.; Singh, J.; Yu-Yueh, F.

    2012-01-01

    Dual-energy computed tomography (CT) scanning is a rapidly emerging imaging technique employed in nondestructive evaluation of various materials. CT has been used for characterizing rocks and visualizing multiphase flow through rocks for over 25 years. The most common technique for dual-energy CT scanning relies on homogeneous calibration standards to produce the most accurate decoupled data. However, the use of calibration standards with impurities increases the probability of error in the reconstructed data and results in poor rock characterization. Laser-induced breakdown spectroscopy was used to determine impurity concentration in a set of commercially purchased calibration standards used in dual-energy scanning for material identification with coal samples. Two calibration models were developed by using univariate calibration with the internal ratio method and multiple linear regression. Seven elements (Al, Fe, Mg, Na, Ni, Sr, and Ti) were examined in five different samples containing varying amounts of each ion to compare calibration from univariate data analysis and from multivariate data analysis. The contaminant concentrations were also measured by a commercially available inductively coupled plasma optical emission spectroscopy instrument, and the data were used as a reference in developing calibration curves for a modified version of the single linear regression model and the multiple linear regression model.

  7. Facility for spectral irradiance and radiance responsivity calibrations using uniform sources

    SciTech Connect (OSTI)

    Brown, Steven W.; Eppeldauer, George P.; Lykke, Keith R

    2006-11-10

    Detectors have historically been calibrated for spectral power responsivity at the National Institute of Standards and Technology by using a lamp-monochromator system to tune the wavelength of the excitation source. Silicon detectors can be calibrated in the visible spectral region with combined standard uncertainties at the 0.1% level. However,uncertainties increase dramatically when measuring an instrument's spectral irradiance or radiance responsivity. We describe what we believe to be a new laser-based facility for spectral irradiance and radiance responsivity calibrations using uniform sources (SIRCUS) that was developed to calibrate instruments directly in irradiance or radiance mode with uncertainties approaching or exceeding those available for spectral power responsivity calibrations. In SIRCUS, the emission from high-power, tunable lasers is introduced into an integrating sphere using optical fibers, producing uniform, quasi-Lambertian, high-radiant-flux sources. Reference standard irradiance detectors, calibrated directly against national primary standards for spectral power responsivity and aperture area measurement,are used to determine the irradiance at a reference plane. Knowing the measurement geometry, the source radiance can be readily determined as well. The radiometric properties of the SIRCUS source coupled with state-of-the-art transfer standard radiometers whose responsivities are directly traceable to primary national radiometric scales result in typical combined standard uncertainties in irradiance and radiance responsivity calibrations of less than 0.1%. The details of the facility and its effect on primary national radiometric scales are discussed.

  8. Improved Multivariate Calibration Models for Corn Stover Feedstock and Dilute-Acid Pretreated Corn Stover

    SciTech Connect (OSTI)

    Wolfrum, E. J.; Sluiter, A. D.

    2009-01-01

    We have studied rapid calibration models to predict the composition of a variety of biomass feedstocks by correlating near-infrared (NIR) spectroscopic data to compositional data produced using traditional wet chemical analysis techniques. The rapid calibration models are developed using multivariate statistical analysis of the spectroscopic and wet chemical data. This work discusses the latest versions of the NIR calibration models for corn stover feedstock and dilute-acid pretreated corn stover. Measures of the calibration precision and uncertainty are presented. No statistically significant differences (p = 0.05) are seen between NIR calibration models built using different mathematical pretreatments. Finally, two common algorithms for building NIR calibration models are compared; no statistically significant differences (p = 0.05) are seen for the major constituents glucan, xylan, and lignin, but the algorithms did produce different predictions for total extractives. A single calibration model combining the corn stover feedstock and dilute-acid pretreated corn stover samples gave less satisfactory predictions than the separate models.

  9. CALIBRATING C-IV-BASED BLACK HOLE MASS ESTIMATORS

    SciTech Connect (OSTI)

    Park, Daeseong; Woo, Jong-Hak; Shin, Jaejin [Astronomy Program, Department of Physics and Astronomy, Seoul National University, Seoul 151-742 (Korea, Republic of); Denney, Kelly D., E-mail: pds2001@astro.snu.ac.kr, E-mail: woo@astro.snu.ac.kr, E-mail: jjshin@astro.snu.ac.kr, E-mail: kelly@dark-cosmology.dk [Dark Cosmology Centre, Niels Bohr Institute, Juliane Maries Vej 30, DK-2100 Copenhagen O (Denmark)

    2013-06-20

    We present the single-epoch black hole mass estimators based on the C IV {lambda}1549 broad emission line, using the updated sample of the reverberation-mapped active galactic nuclei and high-quality UV spectra. By performing multi-component spectral fitting analysis, we measure the C IV line widths (FWHM{sub C{sub IV}} and line dispersion, {sigma}{sub C{sub IV}}) and the continuum luminosity at 1350 A (L{sub 1350}) to calibrate the C-IV-based mass estimators. By comparing with the H{beta} reverberation-based masses, we provide new mass estimators with the best-fit relationships, i.e., M{sub BH}{proportional_to}L{sub 1350}{sup 0.50{+-}0.07}{sigma}{sub C{sub IV}{sup 2}} and M{sub BH}{proportional_to}L{sub 1350}{sup 0.52{+-}0.09} FWHM{sub C{sub IV}{sup 0.56{+-}0.48}}. The new C-IV-based mass estimators show significant mass-dependent systematic difference compared to the estimators commonly used in the literature. Using the published Sloan Digital Sky Survey QSO catalog, we show that the black hole mass of high-redshift QSOs decreases on average by {approx}0.25 dex if our recipe is adopted.

  10. Self-calibrated active pyrometer for furnace temperature measurements

    DOE Patents [OSTI]

    Woskov, Paul P. (Bedford, MA); Cohn, Daniel R. (Chestnuthill, MA); Titus, Charles H. (Newtown Square, PA); Surma, Jeffrey E. (Kennewick, WA)

    1998-01-01

    Pyrometer with a probe beam superimposed on its field-of-view for furnace temperature measurements. The pyrometer includes a heterodyne millimeter/sub-millimeter-wave or microwave receiver including a millimeter/sub-millimeter-wave or microwave source for probing. The receiver is adapted to receive radiation from a surface whose temperature is to be measured. The radiation includes a surface emission portion and a surface reflection portion which includes the probe beam energy reflected from the surface. The surface emission portion is related to the surface temperature and the surface reflection portion is related to the emissivity of the surface. The simultaneous measurement of surface emissivity serves as a real time calibration of the temperature measurement. In an alternative embodiment, a translatable base plate and a visible laser beam allow slow mapping out of interference patterns and obtaining peak values therefor. The invention also includes a waveguide having a replaceable end portion, an insulating refractory sleeve and/or a source of inert gas flow. The pyrometer may be used in conjunction with a waveguide to form a system for temperature measurements in a furnace. The system may employ a chopper or alternatively, be constructed without a chopper. The system may also include an auxiliary reflector for surface emissivity measurements.

  11. A calibration procedure to improve global rice yield simulations with EPIC

    SciTech Connect (OSTI)

    Xiong, Wei; Balkovic, Juraj; van der Velde, M.; Zhang, Xuesong; Izaurralde, Roberto C.; Skalsky, Rastislav; Lin, Erda; Mueller, Nathan; Obersteiner, Michael

    2014-02-01

    Crop models are increasingly used to assess impacts of climate change/variability and management practices on productivity and environmental performance of alternative cropping systems. Calibration is an important procedure to improve reliability of model simulations, especially for large area applications. However, global-scale crop model calibration has rarely been exercised due to limited data availability and expensive computing cost. Here we present a simple approach to calibrate Environmental Policy Integrated Climate (EPIC) model for a global implementation of rice. We identify four parameters (potential heat unit – PHU, planting density – PD, harvest index – HI, and biomass energy ratio – BER) and calibrate them regionally to capture the spatial pattern of reported rice yield in 2000. Model performance is assessed by comparing simulated outputs with independent FAO national data. The comparison demonstrates that the global calibration scheme performs satisfactorily in reproducing the spatial pattern of rice yield, particularly in main rice production areas. Spatial agreement increases substantially when more parameters are selected and calibrated, but with varying efficiencies. Among the parameters, PHU and HI exhibit the highest efficiencies in increasing the spatial agreement. Simulations with different calibration strategies generate a pronounced discrepancy of 5–35% in mean yields across latitude bands, and a small to moderate difference in estimated yield variability and yield changing trend for the period of 1981–2000. Present calibration has little effects in improving simulated yield variability and trends at both regional and global levels, suggesting further works are needed to reproduce temporal variability of reported yields. This study highlights the importance of crop models’ calibration, and presents the possibility of a transparent and consistent up scaling approach for global crop simulations given current availability of global databases of weather, soil, crop calendar, fertilizer and irrigation management information, and reported yield.

  12. Image plate characterization and absolute calibration to low kilo-electron-volt electrons

    SciTech Connect (OSTI)

    Busold, S.; Philipp, K.; Otten, A.; Roth, M.

    2014-11-15

    We report on the characterization of an image plate and its absolute calibration to electrons in the low keV energy range (1–30 keV). In our case, an Agfa MD4.0 without protection layer was used in combination with a Fuji FLA7000 scanner. The calibration data are compared to other published data and a consistent picture of the sensitivity of image plates to electrons is obtained, which suggests a validity of the obtained calibration up to 100 keV.

  13. Calibration of Time Of Flight Detectors Using Laser-driven Neutron Source

    E-Print Network [OSTI]

    S. R. Mirfayzi; S. Kar; H. Ahmed; A. G. Krygier; A. Green; A. Alejo; R. Clarke; R. R. Freeman; J. Fuchs; D. Jung; A. Kleinschmidt; J. T. Morrison; Z. Najmudin; H. Nakamura; P. Norreys; M. Oliver; M. Roth; L. Vassura; M. Zepf; M. Borghesi

    2015-06-15

    Calibration of three scintillators (EJ232Q, BC422Q and EJ410) in a time-of-flight (TOF) arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors are shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.

  14. Empirical Calibration of Hubble Space Telescope WFPC2 F606W and F814W Photometry

    E-Print Network [OSTI]

    Samir Salim; Andrew Gould

    1998-09-30

    Using the ground-based V and I photometry of a sample of stars from the Groth Strip, we obtain the first empirical calibration of the F606W and F814W Hubble Space Telescope WFPC2 filters for 0.5calibrations currently in use. Both calibrations are found to require corrections to zero points and color-terms.

  15. Simultaneously non-linear energy calibration of CMS calorimeters for single pions and electrons

    E-Print Network [OSTI]

    J. Damgov; V. Genchev; S. Cht. Mavrodiev

    2001-10-11

    CMS calorimeter energy calibration was done in the full CMS simulated geometry for the pseudorapidity region eta = 0. The samples of single pion events were generated with a set of incident energies from 5 GeV to 3 TeV and for single electrons from 5 to 500 GeV. The analysis of the simulated data shows that standard calibration using just sampling coefficients for calorimeter parts with different sampling ratio gives nonlinear calorimeter response. Non-linear calibration technique was applied simultaneously for pion and electron beams which is preparation for jets energy reconstruction. It improve calorimeter energy resolution for pions and restore the calorimeter linearity.

  16. Embedded calibration system for the DIII-D Langmuir probe analog fiber optic links

    SciTech Connect (OSTI)

    Watkins, J. G. [Sandia National Laboratories, Livermore, California (United States); Rajpal, R.; Mandaliya, H. [Institute for Plasma Research, Bhat, Gandhinagar, Gujarat (India); Watkins, M.; Boivin, R. L. [General Atomics, San Diego, California (United States)

    2012-10-15

    This paper describes a generally applicable technique for simultaneously measuring offset and gain of 64 analog fiber optic data links used for the DIII-D fixed Langmuir probes by embedding a reference voltage waveform in the optical transmitted signal before every tokamak shot. The calibrated data channels allow calibration of the power supply control fiber optic links as well. The array of fiber optic links and the embedded calibration system described here makes possible the use of superior modern data acquisition electronics in the control room.

  17. A precise in situ calibration of the RHIC H-Jet polarimeter

    SciTech Connect (OSTI)

    Poblaguev, A. A.

    2014-03-05

    Two new methods of calibration of the hydrogen jet target polarimeter (H-Jet) at RHIC are discussed. First method is based on the measurement of low amplitude signal time of fast particles penetrating through detector. The second, geometry based, method employs correlation between z-coordinate of the recoil proton and its kinetic energy. Both methods can be used for in situ calibration of the H-Jet polarimeter. These two methods are compared with a traditional calibration of the H-Jet which uses ?-sources.

  18. Balance Calibration – A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance.

    SciTech Connect (OSTI)

    Mike Stears

    2010-07-01

    Paper Title: Balance Calibration – A method for assigning a direct-reading uncertainty to an electronic balance. Intended Audience: Those who calibrate or use electronic balances. Abstract: As a calibration facility, we provide on-site (at the customer’s location) calibrations of electronic balances for customers within our company. In our experience, most of our customers are not using their balance as a comparator, but simply putting an unknown quantity on the balance and reading the displayed mass value. Manufacturer’s specifications for balances typically include specifications such as readability, repeatability, linearity, and sensitivity temperature drift, but what does this all mean when the balance user simply reads the displayed mass value and accepts the reading as the true value? This paper discusses a method for assigning a direct-reading uncertainty to a balance based upon the observed calibration data and the environment where the balance is being used. The method requires input from the customer regarding the environment where the balance is used and encourages discussion with the customer regarding sources of uncertainty and possible means for improvement; the calibration process becomes an educational opportunity for the balance user as well as calibration personnel. This paper will cover the uncertainty analysis applied to the calibration weights used for the field calibration of balances; the uncertainty is calculated over the range of environmental conditions typically encountered in the field and the resulting range of air density. The temperature stability in the area of the balance is discussed with the customer and the temperature range over which the balance calibration is valid is decided upon; the decision is based upon the uncertainty needs of the customer and the desired rigor in monitoring by the customer. Once the environmental limitations are decided, the calibration is performed and the measurement data is entered into a custom spreadsheet. The spreadsheet uses measurement results, along with the manufacturer’s specifications, to assign a direct-read measurement uncertainty to the balance. The fact that the assigned uncertainty is a best-case uncertainty is discussed with the customer; the assigned uncertainty contains no allowance for contributions associated with the unknown weighing sample, such as density, static charges, magnetism, etc. The attendee will learn uncertainty considerations associated with balance calibrations along with one method for assigning an uncertainty to a balance used for non-comparison measurements.

  19. A New Perspective for the Calibration of Computational Predictor Models.

    SciTech Connect (OSTI)

    Crespo, Luis Guillermo

    2014-11-01

    This paper presents a framework for calibrating computational models using data from sev- eral and possibly dissimilar validation experiments. The offset between model predictions and observations, which might be caused by measurement noise, model-form uncertainty, and numerical error, drives the process by which uncertainty in the models parameters is characterized. The resulting description of uncertainty along with the computational model constitute a predictor model. Two types of predictor models are studied: Interval Predictor Models (IPMs) and Random Predictor Models (RPMs). IPMs use sets to characterize uncer- tainty, whereas RPMs use random vectors. The propagation of a set through a model makes the response an interval valued function of the state, whereas the propagation of a random vector yields a random process. Optimization-based strategies for calculating both types of predictor models are proposed. Whereas the formulations used to calculate IPMs target solutions leading to the interval value function of minimal spread containing all observations, those for RPMs seek to maximize the models' ability to reproduce the distribution of obser- vations. Regarding RPMs, we choose a structure for the random vector (i.e., the assignment of probability to points in the parameter space) solely dependent on the prediction error. As such, the probabilistic description of uncertainty is not a subjective assignment of belief, nor is it expected to asymptotically converge to a fixed value, but instead it is a description of the model's ability to reproduce the experimental data. This framework enables evaluating the spread and distribution of the predicted response of target applications depending on the same parameters beyond the validation domain (i.e., roll-up and extrapolation).

  20. Limits of Predictability in Commuting Flows in the Absence of Data for Calibration

    E-Print Network [OSTI]

    Yang, Yingxiang

    The estimation of commuting flows at different spatial scales is a fundamental problem for different areas of study. Many current methods rely on parameters requiring calibration from empirical trip volumes. Their values ...

  1. The On-Orbit Calibrations for the Fermi Large Area Telescope

    SciTech Connect (OSTI)

    Abdo, Aous A.; /Naval Research Lab, Wash., D.C.; Ackermann, M.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Ajello, M.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Ampe, J.; /Naval Research Lab, Wash., D.C.; Anderson, B.; /UC, Santa Cruz; Atwood, W.B.; /UC, Santa Cruz; Axelsson, M.; /Stockholm U., OKC /Stockholm U.; Bagagli, R.; /INFN, Pisa; Baldini, L.; /INFN, Pisa; Ballet, J.; /DAPNIA, Saclay; Barbiellini, Guido; /INFN, Trieste /Trieste U.; Bartelt, J.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bastieri, Denis; /INFN, Padua /Padua U.; Baughman, B.M.; /Ohio State U.; Bechtol, K.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bederede, D.; /DAPNIA, Saclay; Bellardi, F.; /INFN, Pisa; Bellazzini, R.; /INFN, Pisa; Belli, F.; /Frascati /Rome U.,Tor Vergata; Berenji, B.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bisello, D.; /INFN, Padua /Padua U. /Garching, Max Planck Inst., MPE /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Ecole Polytechnique /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /INFN, Perugia /Perugia U. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /DAPNIA, Saclay /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /INFN, Pisa /INFN, Pisa /Bari U. /INFN, Bari /Ecole Polytechnique /Washington U., Seattle /INFN, Padua /Padua U. /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /IASF, Milan /IASF, Milan /Kalmar U. /Stockholm U., OKC /Royal Inst. Tech., Stockholm /DAPNIA, Saclay /ASDC, Frascati /INFN, Pisa /INFN, Perugia /Perugia U. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /George Mason U. /Naval Research Lab, Wash., D.C. /NASA, Goddard /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /DAPNIA, Saclay /NASA, Goddard /INFN, Perugia /Perugia U.; /more authors..

    2011-11-17

    The Large Area Telescope (LAT) on-board the Fermi Gamma-ray Space Telescope began its on-orbit operations on June 23, 2008. Calibrations, defined in a generic sense, correspond to synchronization of trigger signals, optimization of delays for latching data, determination of detector thresholds, gains and responses, evaluation of the perimeter of the South Atlantic Anomaly (SAA), measurements of live time, of absolute time, and internal and spacecraft boresight alignments. Here we describe on-orbit calibration results obtained using known astrophysical sources, galactic cosmic rays, and charge injection into the front-end electronics of each detector. Instrument response functions will be described in a separate publication. This paper demonstrates the stability of calibrations and describes minor changes observed since launch. These results have been used to calibrate the LAT datasets to be publicly released in August 2009.

  2. Calibration of Stochastic Convenience Yield Models For Crude Oil Using the Kalman Filter

    E-Print Network [OSTI]

    Vuik, Kees

    Calibration of Stochastic Convenience Yield Models For Crude Oil Using the Kalman Filter A physical bales of oil rather than future contracts. Should their be a sudden shock-situation wherein the de

  3. TweezPal Optical tweezers analysis and calibration software Natan Osterman1

    E-Print Network [OSTI]

    Osterman, Natan

    Keywords: laser tweezers, optical trapping, calibration CPC Library Classification: 3; 4.14; 18; 23; External routines/libraries used:- CPC Program Library subprograms used:- Nature of problem: Quick, robust

  4. The Chandra High Energy Transmission Grating: Design, Fabrication, Ground Calibration and Five Years in Flight

    E-Print Network [OSTI]

    Canizares, Claude R.

    Details of the design, fabrication, and ground and flight calibration of the High Energy Transmission Grating (HETG) on the Chandra X?Ray Observatory are presented after 5 years of flight experience. Specifics include the ...

  5. A STUDY OF PROPERTIES OF TYPE IA SUPERNOVA AND THE CALIBRATION OF MULTIBAND PHOTOMETRY 

    E-Print Network [OSTI]

    Bastola, Deepak 1988-

    2012-04-27

    The peak luminosity of Type Ia Supernova (SN) can be calibrated using a distance independent luminosity parameter called the decline rate parameter (?m15 (B) to get accurate distances to the galaxies. The photometry gathered from the telescopes...

  6. Optimal Extraction of Cosmological Information from Supernova Datain the Presence of Calibration Uncertainties

    SciTech Connect (OSTI)

    Kim, Alex G.; Miquel, Ramon

    2005-09-26

    We present a new technique to extract the cosmological information from high-redshift supernova data in the presence of calibration errors and extinction due to dust. While in the traditional technique the distance modulus of each supernova is determined separately, in our approach we determine all distance moduli at once, in a process that achieves a significant degree of self-calibration. The result is a much reduced sensitivity of the cosmological parameters to the calibration uncertainties. As an example, for a strawman mission similar to that outlined in the SNAP satellite proposal, the increased precision obtained with the new approach is roughly equivalent to a factor of five decrease in the calibration uncertainty.

  7. Fully automatic calibration of LIDAR and video streams from a vehicle

    E-Print Network [OSTI]

    Bileschi, Stanley M.

    This work describes a fully automatic technique to calibrate a geometric mapping between lidar and video feeds on a mobile ground-based platform. This data association is a crucial first step for any multi-modal scene ...

  8. On The Complexity Of Energy Efficient Pairwise Calibration In Embedded Sensors Huseyin Akcan

    E-Print Network [OSTI]

    Akcan, Huseyin

    advances in nanotechnology enabled the use of microelectromechanical systems (MEMS) in various appli integrated in microelectromechanical systems (MEMS) are getting in- creasingly common every day. The advances- cation areas. With the integration of various sensor devices into MEMS, autonomously calibrating

  9. Development of neural network calibration algorithms for multi-port pressure probes 

    E-Print Network [OSTI]

    Kinser Robert Eric

    1996-01-01

    mini-5-hole probe having a diameter of only 0.065" is calibrated and used to measure three dimensional velocity data about a delta wing model to demonstrate PROBENET's real world application....

  10. Formal Calibration Methodology for CFD Model Development to Support the Operation of Energy Efficient Buildings 

    E-Print Network [OSTI]

    Hajdukiewicz, M.; Keane, M.; O'Flynn, B.; O'Grady, W.

    2010-01-01

    . The work focuses on developing systematically calibrated CFD models for controlled environments that include clean rooms, health environments, pharmaceutical storage rooms and information and communication technology locations, utilizing wireless sensor...

  11. Designing and testing the neutron source deployment system and calibration plan for a dark matter detector

    E-Print Network [OSTI]

    Westerdale, Shawn (Shawn S.)

    2011-01-01

    In this thesis, we designed and tested a calibration and deployment system for the MiniCLEAN dark matter detector. The deployment system uses a computer controlled winch to lower a canister containing a neutron source into ...

  12. HYDROCARBON LIQUID FLOW CALIBRATION SERVICE NIST Special Publication 250-1039

    E-Print Network [OSTI]

    Magee, Joseph W.

    HYDROCARBON LIQUID FLOW CALIBRATION SERVICE NIST Special Publication 250-1039 T. T. Yeh, Jesús and Technology Laboratory National Institute of Standards and Technology Gaithersburg, MD 20899 #12;Hydrocarbon......................................... 3 4.0 Description of the Hydrocarbon Liquid Flow Standard

  13. Design of compact frequency synthesizer for self-calibration in RF circuits 

    E-Print Network [OSTI]

    Park, Sanghoon

    2005-11-01

    A compact frequency synthesizer based on a phase locked loop (PLL) is designed for the self-calibration in RF circuits. The main advantage of the presented frequency synthesizer is that it can be built in a small silicon ...

  14. Study on Groundwater Quality Parameter Variation Due to Temperature Change in Calibration Solution and Instrumentation

    E-Print Network [OSTI]

    Ma, Lena

    1. Title Study on Groundwater Quality Parameter Variation Due to Temperature Change in Calibration of Florida, Gainesville, FL 4. Abstract Measurement of groundwater quality parameters is essential shown that there is some variation in measured groundwater quality parameters when

  15. A Calibration Methodology for Retrofit Projects Using Short-Term Monitoring and Disaggregated Energy Use Data 

    E-Print Network [OSTI]

    Soebarto, V. I.; Degelman, L. O.

    1996-01-01

    This paper presents an improved methodology to calibrate energy simulation models to better represent the actual energy use breakdowns in existing buildings. The goal of this methodology is to help architects and engineers accurately determine...

  16. Reliability-based calibration of design seismic response spectra and structural acceptance criteria

    E-Print Network [OSTI]

    Baker, Jack W.

    Reliability-based calibration of design seismic response spectra and structural acceptance criteria: Earthquake engineering design requires an evaluation of the structure's reliability over future seismic loads alternate "explicit" check, which commonly specifies a design spectrum and associated structural response

  17. Behavioral modeling and digital calibration of pipeline analog to digital converters 

    E-Print Network [OSTI]

    Bilhan, Erkan

    2001-01-01

    This research focuses on digital calibration of pipeline analog to digital converters (ADCs) and also modeling of error sources and design parameters of pipeline ADCs. Modern applications such as communications systems require high resolution ADCs...

  18. A Systematic Methodology to Underpin the CC® Process Using Calibrated BES Models 

    E-Print Network [OSTI]

    White, G.; Keane, M.; Raftery, P.; Coakley, D.

    2011-01-01

    This paper describes a theoretical framework for utilizing whole building and reduced order calibrated BES models to underpin a systematic Continuous Commissioning® (CC®) process for building environmental optimisation and effective energy...

  19. Cross Calibration of Telescope Optical Throughput Efficiencies using Reconstructed Shower Energies for the Cherenkov Telescope Array

    E-Print Network [OSTI]

    Mitchell, A M W; Hofmann, W; Bernloehr, K

    2015-01-01

    For reliable event reconstruction of Imaging Atmospheric Cherenkov Telescopes (IACTs), calibration of the optical throughput efficiency is required. Within current facilities, this is achieved through the use of ring shaped images generated by muons. Here, a complementary approach is explored, achieving cross calibration of elements of IACT arrays through pairwise comparisons between telescopes, focussing on its applicability to the upcoming Cherenkov Telescope Array (CTA). Intercalibration of telescopes of a particular type using eventwise comparisons of shower image amplitudes has previously been demonstrated to recover the relative telescope optical responses. A method utilising the reconstructed energy as an alternative to image amplitude is presented, enabling cross calibration between telescopes of varying types within an IACT array. Monte Carlo studies for two plausible CTA layouts have shown that this calibration procedure recovers the relative telescope response efficiencies at the few percent level.

  20. Calibration Sets for Multiprimary Displays: Representation, Vi-sualization, and Applications

    E-Print Network [OSTI]

    Sharma, Gaurav

    . For instance, in organic light emitting diode (OLED) and other similar displays, where power is controlled and of alternative calibration strate- gies for multiprimary displays. For display technologies such as OLED, where

  1. Multivariate Calibration Models for Sorghum Composition using Near-Infrared Spectroscopy

    SciTech Connect (OSTI)

    Wolfrum, E.; Payne, C.; Stefaniak, T.; Rooney, W.; Dighe, N.; Bean, B.; Dahlberg, J.

    2013-03-01

    NREL developed calibration models based on near-infrared (NIR) spectroscopy coupled with multivariate statistics to predict compositional properties relevant to cellulosic biofuels production for a variety of sorghum cultivars. A robust calibration population was developed in an iterative fashion. The quality of models developed using the same sample geometry on two different types of NIR spectrometers and two different sample geometries on the same spectrometer did not vary greatly.

  2. Model Calibration and Optics Correction Using Orbit Response Matrix in the Fermilab Booster

    SciTech Connect (OSTI)

    Lebedev, V.A.; Prebys, E.; /Fermilab; Petrenko, A.V.; /Novosibirsk, IYF; Kopp, S.E.; McAteer, M.J.; /Texas U.

    2012-05-01

    We have calibrated the lattice model and measured the beta and dispersion functions in Fermilab's fast-ramping Booster synchrotron using the Linear Optics from Closed Orbit (LOCO) method. We used the calibrated model to implement ramped coupling, dispersion, and beta-beating corrections throughout the acceleration cycle, reducing horizontal beta beating from its initial magnitude of {approx}30% to {approx}10%, and essentially eliminating vertical beta-beating and transverse coupling.

  3. Absolute intensity calibration of the 32-channel heterodyne radiometer on experimental advanced superconducting tokamak

    SciTech Connect (OSTI)

    Liu, X.; Zhao, H. L.; Liu, Y. Li, E. Z.; Han, X.; Ti, A.; Hu, L. Q.; Zhang, X. D.; Domier, C. W.; Luhmann, N. C.

    2014-09-15

    This paper presents the results of the in situ absolute intensity calibration for the 32-channel heterodyne radiometer on the experimental advanced superconducting tokamak. The hot/cold load method is adopted, and the coherent averaging technique is employed to improve the signal to noise ratio. Measured spectra and electron temperature profiles are compared with those from an independent calibrated Michelson interferometer, and there is a relatively good agreement between the results from the two different systems.

  4. Design and calibration of a scanning tunneling microscope for large machined surfaces

    SciTech Connect (OSTI)

    Grigg, D.A.; Russell, P.E.; Dow, T.A.

    1988-12-01

    During the last year the large sample STM has been designed, built and used for the observation of several different samples. Calibration of the scanner for prope dimensional interpretation of surface features has been a chief concern, as well as corrections for non-linear effects such as hysteresis during scans. Several procedures used in calibration and correction of piezoelectric scanners used in the laboratorys STMs are described.

  5. Evaluation of Automated Model Calibration Techniques for Residential Building Energy Simulation

    SciTech Connect (OSTI)

    Robertson, J.; Polly, B.; Collis, J.

    2013-09-01

    This simulation study adapts and applies the general framework described in BESTEST-EX (Judkoff et al 2010) for self-testing residential building energy model calibration methods. BEopt/DOE-2.2 is used to evaluate four mathematical calibration methods in the context of monthly, daily, and hourly synthetic utility data for a 1960's-era existing home in a cooling-dominated climate. The home's model inputs are assigned probability distributions representing uncertainty ranges, random selections are made from the uncertainty ranges to define 'explicit' input values, and synthetic utility billing data are generated using the explicit input values. The four calibration methods evaluated in this study are: an ASHRAE 1051-RP-based approach (Reddy and Maor 2006), a simplified simulated annealing optimization approach, a regression metamodeling optimization approach, and a simple output ratio calibration approach. The calibration methods are evaluated for monthly, daily, and hourly cases; various retrofit measures are applied to the calibrated models and the methods are evaluated based on the accuracy of predicted savings, computational cost, repeatability, automation, and ease of implementation.

  6. Evaluation of Automated Model Calibration Techniques for Residential Building Energy Simulation

    SciTech Connect (OSTI)

    and Ben Polly, Joseph Robertson; Polly, Ben; Collis, Jon

    2013-09-01

    This simulation study adapts and applies the general framework described in BESTEST-EX (Judkoff et al 2010) for self-testing residential building energy model calibration methods. BEopt/DOE-2.2 is used to evaluate four mathematical calibration methods in the context of monthly, daily, and hourly synthetic utility data for a 1960's-era existing home in a cooling-dominated climate. The home's model inputs are assigned probability distributions representing uncertainty ranges, random selections are made from the uncertainty ranges to define "explicit" input values, and synthetic utility billing data are generated using the explicit input values. The four calibration methods evaluated in this study are: an ASHRAE 1051-RP-based approach (Reddy and Maor 2006), a simplified simulated annealing optimization approach, a regression metamodeling optimization approach, and a simple output ratio calibration approach. The calibration methods are evaluated for monthly, daily, and hourly cases; various retrofit measures are applied to the calibrated models and the methods are evaluated based on the accuracy of predicted savings, computational cost, repeatability, automation, and ease of implementation.

  7. Calibration of the Accuscan II In Vivo System for Whole Body Counting

    SciTech Connect (OSTI)

    Orval R. Perry; David L. Georgeson

    2011-08-01

    This report describes the April 2011 calibration of the Accuscan II HpGe In Vivo system for whole body counting. The source used for the calibration was a NIST traceable BOMAB manufactured by DOE as INL2006 BOMAB containing Eu-154, Eu-155, Eu-152, Sb-125 and Y-88 with energies from 27 keV to 1836 keV with a reference date of 11/29/2006. The actual usable energy range was 86.5 keV to 1597 keV on 4/21/2011. The BOMAB was constructed inside the Accuscan II counting 'tub' in the order of legs, thighs, abdomen, thorax/arms, neck, and head. Each piece was taped to the backwall of the counter. The arms were taped to the thorax. The phantom was constructed between the v-ridges on the backwall of the Accuscan II counter. The energy and efficiency calibrations were performed using the INL2006 BOMAB. The calibrations were performed with the detectors in the scanning mode. This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for whole body counting and verified in accordance with ANSI/HPS N13.30-1996 criteria.

  8. Planck 2015 results. VIII. High Frequency Instrument data processing: Calibration and maps

    E-Print Network [OSTI]

    Adam, R; Aghanim, N; Arnaud, M; Ashdown, M; Aumont, J; Baccigalupi, C; Banday, A J; Barreiro, R B; Bartolo, N; Battaner, E; Benabed, K; Benoît, A; Benoit-Lévy, A; Bernard, J -P; Bersanelli, M; Bertincourt, B; Bielewicz, P; Bonavera, L; Bond, J R; Borrill, J; Bouchet, F R; Boulanger, F; Bucher, M; Burigana, C; Calabrese, E; Cardoso, J -F; Catalano, A; Challinor, A; Chamballu, A; Chiang, H C; Christensen, P R; Clements, D L; Colombi, S; Colombo, L P L; Combet, C; Couchot, F; Coulais, A; Crill, B P; Curto, A; Cuttaia, F; Danese, L; Davies, R D; Davis, R J; de Bernardis, P; de Rosa, A; de Zotti, G; Delabrouille, J; Delouis, J -M; Désert, F -X; Diego, J M; Dole, H; Donzelli, S; Doré, O; Douspis, M; Ducout, A; Dupac, X; Efstathiou, G; Elsner, F; Enßlin, T A; Eriksen, H K; Falgarone, E; Fergusson, J; Finelli, F; Forni, O; Frailis, M; Fraisse, A A; Franceschi, E; Frejsel, A; Galeotta, S; Galli, S; Ganga, K; Ghosh, T; Giard, M; Giraud-Héraud, Y; Gjerløw, E; González-Nuevo, J; Górski, K M; Gratton, S; Gruppuso, A; Gudmundsson, J E; Hansen, F K; Hanson, D; Harrison, D L; Henrot-Versillé, S; Herranz, D; Hildebrandt, S R; Hivon, E; Hobson, M; Holmes, W A; Hornstrup, A; Hovest, W; Huffenberger, K M; Hurier, G; Jaffe, A H; Jaffe, T R; Jones, W C; Juvela, M; Keihänen, E; Keskitalo, R; Kisner, T S; Kneissl, R; Knoche, J; Kunz, M; Kurki-Suonio, H; Lagache, G; Lamarre, J -M; Lasenby, A; Lattanzi, M; Lawrence, C R; Jeune, M Le; Leahy, J P; Lellouch, E; Leonardi, R; Lesgourgues, J; Levrier, F; Liguori, M; Lilje, P B; Linden-Vørnle, M; López-Caniego, M; Lubin, P M; Macías-Pérez, J F; Maggio, G; Maino, D; Mandolesi, N; Mangilli, A; Martin, P G; Martínez-González, E; Masi, S; Matarrese, S; Mazzotta, P; McGehee, P; Melchiorri, A; Mendes, L; Mennella, A; Migliaccio, M; Mitra, S; Miville-Deschênes, M -A; Moneti, A; Montier, L; Moreno, R; Morgante, G; Mortlock, D; Moss, A; Mottet, S; Munshi, D; Murphy, J A; Naselsky, P; Nati, F; Natoli, P; Netterfield, C B; Nørgaard-Nielsen, H U; Noviello, F; Novikov, D; Novikov, I; Oxborrow, C A; Paci, F; Pagano, L; Pajot, F; Paoletti, D; Pasian, F; Patanchon, G; Pearson, T J; Perdereau, O; Perotto, L; Perrotta, F; Pettorino, V; Piacentini, F; Piat, M; Pierpaoli, E; Pietrobon, D; Plaszczynski, S; Pointecouteau, E; Polenta, G; Pratt, G W; Prézeau, G; Prunet, S; Puget, J -L; Rachen, J P; Reinecke, M; Remazeilles, M; Renault, C; Renzi, A; Ristorcelli, I; Rocha, G; Rosset, C; Rossetti, M; Roudier, G; Rusholme, B; Sandri, M; Santos, D; Sauvé, A; Savelainen, M; Savini, G; Scott, D; Seiffert, M D; Shellard, E P S; Spencer, L D; Stolyarov, V; Stompor, R; Sudiwala, R; Sutton, D; Suur-Uski, A -S; Sygnet, J -F; Tauber, J A; Terenzi, L; Toffolatti, L; Tomasi, M; Tristram, M; Tucci, M; Tuovinen, J; Valenziano, L; Valiviita, J; Van Tent, B; Vielva, P; Villa, F; Wade, L A; Wandelt, B D; Watson, R; Wehus, I K; Yvon, D; Zacchei, A; Zonca, A

    2015-01-01

    This paper describes the processing applied to the Planck High Frequency Instrument (HFI) cleaned, time-ordered information to produce photometrically calibrated maps in temperature and (for the first time) in polarization. The data from the 2.5 year full mission include almost five independent full-sky surveys. HFI observes the sky over a broad range of frequencies, from 100 to 857 GHz. To get the best accuracy on the calibration over such a large range, two different photometric calibration schemes have been used. The 545 and 857 GHz data are calibrated using models of planetary atmospheric emission. The lower frequencies (from 100 to 353 GHz) are calibrated using the time-variable cosmological microwave background dipole which we call the orbital dipole. This source of calibration only depends on the satellite velocity with respect to the solar system and permits an independent measurement of the amplitude of the CMB solar dipole (3364.5 +/- 0.8 \\mu K) which is 1\\sigma\\ higher than the WMAP measurement wit...

  9. Alternative Data Reduction Procedures for UVES: Wavelength Calibration and Spectrum Addition

    E-Print Network [OSTI]

    Rodger I. Thompson; Jill Bechtold; John H. Black; C. J. A. P. Martins

    2008-12-05

    This paper addresses alternative procedures to the ESO supplied pipeline procedures for the reduction of UVES spectra of two quasar spectra to determine the value of the fundamental constant mu = Mp/Me at early times in the universe. The procedures utilize intermediate product images and spectra produced by the pipeline with alternative wavelength calibration and spectrum addition methods. Spectroscopic studies that require extreme wavelength precision need customized wavelength calibration procedures beyond that usually supplied by the standard data reduction pipelines. An example of such studies is the measurement of the values of the fundamental constants at early times in the universe. This article describes a wavelength calibration procedure for the UV-Visual Echelle Spectrometer on the Very Large Telescope, however, it can be extended to other spectrometers as well. The procedure described here provides relative wavelength precision of better than 3E-7 for the long-slit Thorium-Argon calibration lamp exposures. The gain in precision over the pipeline wavelength calibration is almost entirely due to a more exclusive selection of Th/Ar calibration lines.

  10. Validation and Calibration of Nuclear Thermal Hydraulics Multiscale Multiphysics Models - Subcooled Flow Boiling Study

    SciTech Connect (OSTI)

    Anh Bui; Nam Dinh; Brian Williams

    2013-09-01

    In addition to validation data plan, development of advanced techniques for calibration and validation of complex multiscale, multiphysics nuclear reactor simulation codes are a main objective of the CASL VUQ plan. Advanced modeling of LWR systems normally involves a range of physico-chemical models describing multiple interacting phenomena, such as thermal hydraulics, reactor physics, coolant chemistry, etc., which occur over a wide range of spatial and temporal scales. To a large extent, the accuracy of (and uncertainty in) overall model predictions is determined by the correctness of various sub-models, which are not conservation-laws based, but empirically derived from measurement data. Such sub-models normally require extensive calibration before the models can be applied to analysis of real reactor problems. This work demonstrates a case study of calibration of a common model of subcooled flow boiling, which is an important multiscale, multiphysics phenomenon in LWR thermal hydraulics. The calibration process is based on a new strategy of model-data integration, in which, all sub-models are simultaneously analyzed and calibrated using multiple sets of data of different types. Specifically, both data on large-scale distributions of void fraction and fluid temperature and data on small-scale physics of wall evaporation were simultaneously used in this work’s calibration. In a departure from traditional (or common-sense) practice of tuning/calibrating complex models, a modern calibration technique based on statistical modeling and Bayesian inference was employed, which allowed simultaneous calibration of multiple sub-models (and related parameters) using different datasets. Quality of data (relevancy, scalability, and uncertainty) could be taken into consideration in the calibration process. This work presents a step forward in the development and realization of the “CIPS Validation Data Plan” at the Consortium for Advanced Simulation of LWRs to enable quantitative assessment of the CASL modeling of Crud-Induced Power Shift (CIPS) phenomenon, in particular, and the CASL advanced predictive capabilities, in general. This report is prepared for the Department of Energy’s Consortium for Advanced Simulation of LWRs program’s VUQ Focus Area.

  11. 1006 IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, VOL. 5, NO. 3, JUNE 2012 Inter-Calibration of Microwave Radiometers

    E-Print Network [OSTI]

    Ruf, Christopher

    . 3, JUNE 2012 Inter-Calibration of Microwave Radiometers Using the Vicarious Cold Calibration Double microwave radiometers is combined with the vicarious cold calibration method for calibrating an individual for conical scanning microwave radiometers and quantifies the improvement this method provides compared

  12. Calibration of a Neutron Hydroprobe for Moisture Measurements in Small-Diameter Steel-Cased Boreholes

    SciTech Connect (OSTI)

    Ward, Anderson L.; Wittman, Richard S.

    2009-08-01

    Computation of soil moisture content from thermalized neutron counts for the T-Farm Interim cover requires a calibration relationship but none exists for 2-in tubes. A number of calibration options are available for the neutron probe, including vendor calibration, field calibration, but none of these methods were deemed appropriate for the configuration of interest. The objective of this work was to develop a calibration relation for converting neutron counts measured in 2-in access tubes to soil water content. The calibration method chosen for this study was a computational approach using the Monte Carlo N-Particle Transport Code (MCNP). Model calibration was performed using field measurements in the Hanford calibration models with 6-in access tubes, in air and in the probe shield. The bet-fit model relating known water content to measured neutron counts was an exponential model that was essentially equivalent to that currently being used for 6-in steel cased wells. The MCNP simulations successfully predicted the neutron count rate for the neutron shield and the three calibration models for which data were collected in the field. However, predictions for air were about 65% lower than the measured counts . This discrepancy can be attributed to uncertainties in the configuration used for the air measurements. MCNP-simulated counts for the physical models were essentially equal to the measured counts with values. Accurate prediction of the response in 6-in casings in the three calibration models was motivation to predict the response in 2-in access tubes. Simulations were performed for six of the seven calibration models as well as 4 virtual models with the entire set covering a moisture range of 0 to 40%. Predicted counts for the calibration models with 2-in access tubes were 40 to 50% higher than in the 6-inch tubes. Predicted counts for water were about 60% higher in the 2-in tube than in the 6-in tube. The discrepancy between the 2-in and 6-in tube can be attributed to the smaller air gap between the probe and the 2-in access tube. The best-fit model relating volumetric water content to count ratio (CR) is of the form e^A x CR^B with A=0.3596 ± 0.0216 and B=0.4629 ± 0.0629 and r^2= 0.9998. It is recommended that the calibration function based on the count ratio, rather than raw counts, be used to avoid the effects of electronic noise in the probe that may arise due to the conditions at the time of measurement. These results suggest that the MCNP code can be used to extend calibrations for the neutron probe to different conditions including access tube size as well as composition without the need to construct additional physical models.

  13. Airports of the Future: The Development of Airport Systems

    E-Print Network [OSTI]

    and scope. This is the model for most successful manufacturers and service providers, such as Walmart

  14. Airport sustainability encompasses a wide variety of airport management and

    E-Print Network [OSTI]

    Minnesota, University of

    is to consider renewable energies. Solar photovoltaic (PV), which uses panels to absorb solar energy, is prob- ably the most commonly implemented type of renewable energy. Solar PV panels can be ground a cold winter climate, the efficiency of solar PV is high in Minnesota because of its many sunny days

  15. Hong Kong InternationalHong Kong International AirportAirport

    E-Print Network [OSTI]

    Prevedouros, Panos D.

    recyclingrecycling Mechanized food waste compostersMechanized food waste compostersMechanized food waste compostersMechanized food waste composters which reduce waste volume by up towhich reduce waste volume by up to 90

  16. Water Calibration Measurements for Neutron Radiography: Application to Water Content Quantification in Porous Media

    SciTech Connect (OSTI)

    Kang, Misun [ORNL; Bilheux, Hassina Z [ORNL; Voisin, Sophie [ORNL; Cheng, Chu-lin [University of Tennessee, Knoxville (UTK); Perfect, Edmund [University of Tennessee, Knoxville (UTK); Horita, Juske [Texas Tech University (TTU); Warren, Jeffrey [ORNL

    2013-04-01

    Using neutron radiography, the measurement of water thickness was performed using aluminum (Al) water calibration cells at the High Flux Isotope Reactor (HFIR) Cold-Guide (CG) 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA. Calibration of water thickness is an important step to accurately measure water contents in samples of interest. Neutron attenuation by water does not vary linearly with thickness mainly due to beam hardening and scattering effects. Transmission measurements for known water thicknesses in water calibration cells allow proper correction of the underestimation of water content due to these effects. As anticipated, strong scattering effects were observed for water thicknesses greater than 2 mm when the water calibration cells were positioned close to the face of the detector / scintillator (0 and 2.4 cm away, respectively). The water calibration cells were also positioned 24 cm away from the detector face. These measurements resulted in less scattering and this position (designated as the sample position) was used for the subsequent experimental determination of the neutron attenuation coefficient for water. Neutron radiographic images of moist Flint sand in rectangular and cylindrical containers acquired at the sample position were used to demonstrate the applicability of the water calibration. Cumulative changes in the water volumes within the sand columns during monotonic drainage determined by neutron radiography were compared with those recorded by direct reading from a burette connected to a hanging water column. In general, the neutron radiography data showed very good agreement with those obtained volumetrically using the hanging water-column method. These results allow extension of the calibration equation to the quantification of unknown water contents within other samples of porous media.

  17. A publication of the Airport Technical Assistance Program of the Center for Transportation Studies at the University of Minnesota Winter 2014 Vol. 14, No. 1 For more on the Fall Forum, including video highlights, see www.AirTAP.umn.edu.

    E-Print Network [OSTI]

    Amin, S. Massoud

    at the University of Minnesota Winter 2014 Vol. 14, No. 1 Briefings For more on the Fall Forum, including video department. That full-time staff is augmented with 28 heavy equipment operators in the winter who work got a look at how the airport handles the snow and ice that's part of a typical Minnesota winter

  18. built by airport authority for

    E-Print Network [OSTI]

    Ladkin, Peter B.

    on landing 3.1.1.3.1.1.3 low weight on each main gear wheel 3.1.1.3.1.1.1.3 condition of RWY surface 3 between consequences of design and behaviour expected by pilots 3.1.1.3.2.2 braking systems' logical design 3.1.1.3.2 speed brakes and thrust reverser deployment delayed 3.1.1.3 braking delayed 3

  19. Self-calibration of photometric redshift scatter in weak-lensing surveys

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Zhang, Pengjie; Pen, Ue -Li; Bernstein, Gary

    2010-06-11

    Photo-z errors, especially catastrophic errors, are a major uncertainty for precision weak lensing cosmology. We find that the shear-(galaxy number) density and density-density cross correlation measurements between photo-z bins, available from the same lensing surveys, contain valuable information for self-calibration of the scattering probabilities between the true-z and photo-z bins. The self-calibration technique we propose does not rely on cosmological priors nor parameterization of the photo-z probability distribution function, and preserves all of the cosmological information available from shear-shear measurement. We estimate the calibration accuracy through the Fisher matrix formalism. We find that, for advanced lensing surveys such as themore »planned stage IV surveys, the rate of photo-z outliers can be determined with statistical uncertainties of 0.01-1% for z galaxy distribution bias is likely the most dominant systematic error, whereby photo-z outliers have different redshift distributions and/or bias than non-outliers from the same bin. This bias affects all photo-z calibration techniques based on correlation measurements. As a result, galaxy bias variations of O(0.1) produce biases in photo-z outlier rates similar to the statistical errors of our method, so this galaxy distribution bias may bias the reconstructed scatters at several-? level, but is unlikely to completely invalidate the self-calibration technique.« less

  20. Calibrating Pyrgeometers Outdoors Independent from the Reference Value of the Atmospheric Longwave Irradiance

    SciTech Connect (OSTI)

    Reda, I.; Hickey, J. R.; Grobner, J.; Andreas, A.; Stoffel, T.

    2006-08-01

    In this article, we describe a method for the calibration of thermopile pyrgeometers in the absence of a reference for measurement of atmospheric longwave irradiance. This is referred to as the incoming longwave irradiance in this article. The method is based on an indoor calibration using a low-temperature blackbody source to obtain the calibration coefficients that determine the pyrgeometer's radiation characteristics. From these coefficients the outgoing irradiance of the pyrgeometer can be calculated. The pyrgeometer is then installed outdoors on an aluminum plate that is connected to a circulating temperature bath. By adjusting the temperature bath to the approximate value of the effective sky temperature, the pyrgeometer's body temperature is lowered changing the pyrgeometer's thermopile output. If the incoming longwave irradiance is stable, the slope of the outgoing irradiance versus the pyrgeometer's thermopile output is the outdoor net irradiance responsivity (RSnet), independent of the absolute value of the atmospheric longwave irradiance. The indoor calibration coefficients and the outdoor RSnet are then used in the pyrgeometer equation to calculate the incoming longwave irradiance. To evaluate this method, the calculated irradiance using the derived coefficients was compared to the irradiance measured using a pyrgeometer with direct traceability to the World Infrared Standard Group (WISG). This is maintained at the Physikalisch-Meteorologisches Observatorium Davos, World Radiation Center, Switzerland. Based on results from four pyrgeometers calibrations, this method suggests measurement agreement with the WISG to within +/- 3 W/m2 for all sky conditions.

  1. A likelihood method to cross-calibrate air-shower detectors

    E-Print Network [OSTI]

    H. P. Dembinski; B. Kégl; I. C. Mari?; M. Roth; D. Veberi?

    2015-03-31

    We present a detailed statistical treatment of the energy calibration of hybrid air-shower detectors, which combine a surface detector array and a fluorescence detector, to obtain an unbiased estimate of the calibration curve. The special features of calibration data from air showers prevent unbiased results, if a standard least-squares fit is applied to the problem. We develop a general maximum-likelihood approach, based on the detailed statistical model, to solve the problem. Our approach was developed for the Pierre Auger Observatory, but the applied principles are general and can be transferred to other air-shower experiments, even to the cross-calibration of other observables. Since our general likelihood function is expensive to compute, we derive two approximations with significantly smaller computational cost. In the recent years both have been used to calibrate data of the Pierre Auger Observatory. We demonstrate that these approximations introduce negligible bias when they are applied to simulated toy experiments, which mimic realistic experimental conditions.

  2. Demonstration of emulator-based Bayesian calibration of safety analysis codes: Theory and formulation

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Yurko, Joseph P.; Buongiorno, Jacopo; Youngblood, Robert

    2015-05-28

    System codes for simulation of safety performance of nuclear plants may contain parameters whose values are not known very accurately. New information from tests or operating experience is incorporated into safety codes by a process known as calibration, which reduces uncertainty in the output of the code and thereby improves its support for decision-making. The work reported here implements several improvements on classic calibration techniques afforded by modern analysis techniques. The key innovation has come from development of code surrogate model (or code emulator) construction and prediction algorithms. Use of a fast emulator makes the calibration processes used here withmore »Markov Chain Monte Carlo (MCMC) sampling feasible. This study uses Gaussian Process (GP) based emulators, which have been used previously to emulate computer codes in the nuclear field. The present work describes the formulation of an emulator that incorporates GPs into a factor analysis-type or pattern recognition-type model. This “function factorization” Gaussian Process (FFGP) model allows overcoming limitations present in standard GP emulators, thereby improving both accuracy and speed of the emulator-based calibration process. Calibration of a friction-factor example using a Method of Manufactured Solution is performed to illustrate key properties of the FFGP based process.« less

  3. Calibration of the Accuscan II In Vivo System for I-125 Thyroid Counting

    SciTech Connect (OSTI)

    Ovard R. Perry; David L. Georgeson

    2011-07-01

    This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-125 thyroid counting. The source used for the calibration was a DOE manufactured Am-241/Eu-152 source contained in a 22 ml vial BEA Am-241/Eu-152 RMC II-1 with energies from 26 keV to 344 keV. The center of the detector housing was positioned 64 inches from the vault floor. This position places the approximate center line of the detector housing at the center line of the source in the phantom thyroid tube. The energy and efficiency calibration were performed using an RMC II phantom (Appendix J). Performance testing was conducted using source BEA Am-241/Eu-152 RMC II-1 and Validation testing was performed using an I-125 source in a 30 ml vial (I-125 BEA Thyroid 002) and an ANSI N44.3 phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-125 and verified in accordance with ANSI/HPS N13.30-1996 criteria.

  4. Calibration of the Accuscan II In Vivo System for I-131 Thyroid Counting

    SciTech Connect (OSTI)

    Orval R. Perry; David L. Georgeson

    2011-07-01

    This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-131 thyroid counting. The source used for the calibration was an Analytics mixed gamma source 82834-121 distributed in an epoxy matrix in a Wheaton Liquid Scintillation Vial with energies from 88.0 keV to 1836.1 keV. The center of the detectors was position 64-feet from the vault floor. This position places the approximate center line of the detectors at the center line of the source in the thyroid tube. The calibration was performed using an RMC II phantom (Appendix J). Validation testing was performed using a Ba-133 source and an ANSI N44.3 Phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibrations including verification counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-131 and verified in accordance with ANSI/HPS N13.30-1996 criteria.

  5. A pulsed-laser calibration system for the laser backscatter diagnostics at the Omega laser

    SciTech Connect (OSTI)

    Neumayer, P; Sorce, C; Froula, D H; Rekow, V; Loughman, K; Knight, R; Glenzer, S H; Bahr, R; Seka, W

    2009-10-09

    A calibration system has been developed that allows a direct determination of the sensitivity of the laser backscatter diagnostics at the Omega laser. A motorized mirror at the target location redirects individual pulses of a mJ-class laser onto the diagnostic to allow the in-situ measurement of the local point response of the backscatter diagnostics. Featuring dual wavelength capability at the 2nd and 3rd harmonic of the Nd:YAG laser, both spectral channels of the backscatter diagnostics can be directly calibrated. In addition, channel cross-talk and polarization sensitivity can be determined. The calibration system has been employed repeatedly over the last two years and has enabled precise backscatter measurements of both stimulated Brillouin scattering and stimulated Raman scattering in gas-filled hohlraum targets that emulate conditions relevant to those in inertial confinement fusion targets.

  6. Kinematic calibration of Orthoglide-type mechanisms from observation of parallel leg motions

    E-Print Network [OSTI]

    Pashkevich, Anatoly; Wenger, Philippe

    2009-01-01

    The paper proposes a new calibration method for parallel manipulators that allows efficient identification of the joint offsets using observations of the manipulator leg parallelism with respect to the base surface. The method employs a simple and low-cost measuring system, which evaluates deviation of the leg location during motions that are assumed to preserve the leg parallelism for the nominal values of the manipulator parameters. Using the measured deviations, the developed algorithm estimates the joint offsets that are treated as the most essential parameters to be identified. The validity of the proposed calibration method and efficiency of the developed numerical algorithms are confirmed by experimental results. The sensitivity of the measurement methods and the calibration accuracy are also studied.

  7. Uncertainty Analysis of Spectral Irradiance Reference Standards Used for NREL Calibrations

    SciTech Connect (OSTI)

    Habte, A.; Andreas, A.; Reda, I.; Campanelli, M.; Stoffel, T.

    2013-05-01

    Spectral irradiance produced by lamp standards such as the National Institute of Standards and Technology (NIST) FEL-type tungsten halogen lamps are used to calibrate spectroradiometers at the National Renewable Energy Laboratory. Spectroradiometers are often used to characterize spectral irradiance of solar simulators, which in turn are used to characterize photovoltaic device performance, e.g., power output and spectral response. Therefore, quantifying the calibration uncertainty of spectroradiometers is critical to understanding photovoltaic system performance. In this study, we attempted to reproduce the NIST-reported input variables, including the calibration uncertainty in spectral irradiance for a standard NIST lamp, and quantify uncertainty for measurement setup at the Optical Metrology Laboratory at the National Renewable Energy Laboratory.

  8. COSMICFLOWS-2: I-BAND LUMINOSITY-H I LINEWIDTH CALIBRATION

    SciTech Connect (OSTI)

    Tully, R. Brent; Courtois, Helene M. [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States)

    2012-04-10

    In order to measure distances with minimal systematics using the correlation between galaxy luminosities and rotation rates it is necessary to adhere to a strict and tested recipe. We now derive a measure of rotation from a new characterization of the width of a neutral hydrogen line profile. Additionally, new photometry and zero-point calibration data are available. Particularly the introduction of a new linewidth parameter necessitates the reconstruction and absolute calibration of the luminosity-linewidth template. The slope of the new template is set by 267 galaxies in 13 clusters. The zero point is set by 36 galaxies with Cepheid or tip of the red giant branch distances. Tentatively, we determine H{sub 0} {approx} 75 km s{sup -1} Mpc{sup -1}. Distances determined using the luminosity-linewidth calibration will contribute to the distance compendium Cosmicflows-2.

  9. Flasher and muon-based calibration of the GCT telescopes proposed for the Cherenkov Telescope Array

    E-Print Network [OSTI]

    Brown, Anthony M; Chadwick, Paula M; Daniel, Michael; White, Richard

    2015-01-01

    The GCT is a dual-mirror Small-Sized-Telescope prototype proposed for the Cherenkov Telescope Array. Calibration of the GCT's camera is primarily achieved with LED-based flasher units capable of producing $\\sim4$ ns FWHM pulses of 400 nm light across a large dynamic range, from 0.1 up to 1000 photoelectrons. The flasher units are housed in the four corners of the camera's focal plane and illuminate it via reflection from the secondary mirror. These flasher units are adaptable to allow several calibration scenarios to be accomplished: camera flat-fielding, linearity measurements (up to and past saturation), and gain estimates from both single pe measurements and from the photon statistics at various high illumination levels. In these proceedings, the performance of the GCT flashers is described, together with ongoing simulation work to quantify the efficiency of using muon rings as an end-to-end calibration for the optical throughput of the GCT.

  10. Poster — Thur Eve — 42: Radiochromic film calibration for low-energy seed brachytherapy dose measurement

    SciTech Connect (OSTI)

    Morrison, H; Menon, G; Sloboda, R

    2014-08-15

    The purpose of this study was to investigate the accuracy of radiochromic film calibration procedures used in external beam radiotherapy when applied to I-125 brachytherapy sources delivering higher doses, and to determine any necessary modifications to achieve similar accuracy in absolute dose measurements. GafChromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 6 MV, 75 kVp and (?28 keV) I-125 photon sources. A custom phantom was used for the I-125 irradiations to obtain a larger film area with nearly constant dose to reduce the effects of film heterogeneities on the optical density (OD) measurements. RGB transmission images were obtained with an Epson 10000XL flatbed scanner, and calibration curves relating OD and dose using a rational function were determined for each colour channel and at each energy using a non-linear least square minimization method. Differences found between the 6 MV calibration curve and those for the lower energy sources are large enough that 6 MV beams should not be used to calibrate film for low-energy sources. However, differences between the 75 kVp and I-125 calibration curves were quite small; indicating that 75 kVp is a good choice. Compared with I-125 irradiation, this gives the advantages of lower type B uncertainties and markedly reduced irradiation time. To obtain high accuracy calibration for the dose range up to 35 Gy, two-segment piece-wise fitting was required. This yielded absolute dose measurement accuracy above 1 Gy of ?2% for 75 kVp and ?5% for I-125 seed exposures.

  11. Principles and applications of measurement and uncertainty analysis in research and calibration

    SciTech Connect (OSTI)

    Wells, C.V.

    1992-11-01

    Interest in Measurement Uncertainty Analysis has grown in the past several years as it has spread to new fields of application, and research and development of uncertainty methodologies have continued. This paper discusses the subject from the perspectives of both research and calibration environments. It presents a history of the development and an overview of the principles of uncertainty analysis embodied in the United States National Standard, ANSI/ASME PTC 19.1-1985, Measurement Uncertainty. Examples are presented in which uncertainty analysis was utilized or is needed to gain further knowledge of a particular measurement process and to characterize final results. Measurement uncertainty analysis provides a quantitative estimate of the interval about a measured value or an experiment result within which the true value of that quantity is expected to lie. Years ago, Harry Ku of the United States National Bureau of Standards stated that The informational content of the statement of uncertainty determines, to a large extent, the worth of the calibrated value.'' Today, that statement is just as true about calibration or research results as it was in 1968. Why is that true What kind of information should we include in a statement of uncertainty accompanying a calibrated value How and where do we get the information to include in an uncertainty statement How should we interpret and use measurement uncertainty information This discussion will provide answers to these and other questions about uncertainty in research and in calibration. The methodology to be described has been developed by national and international groups over the past nearly thirty years, and individuals were publishing information even earlier. Yet the work is largely unknown in many science and engineering arenas. I will illustrate various aspects of uncertainty analysis with some examples drawn from the radiometry measurement and calibration discipline from research activities.

  12. Principles and applications of measurement and uncertainty analysis in research and calibration

    SciTech Connect (OSTI)

    Wells, C.V.

    1992-11-01

    Interest in Measurement Uncertainty Analysis has grown in the past several years as it has spread to new fields of application, and research and development of uncertainty methodologies have continued. This paper discusses the subject from the perspectives of both research and calibration environments. It presents a history of the development and an overview of the principles of uncertainty analysis embodied in the United States National Standard, ANSI/ASME PTC 19.1-1985, Measurement Uncertainty. Examples are presented in which uncertainty analysis was utilized or is needed to gain further knowledge of a particular measurement process and to characterize final results. Measurement uncertainty analysis provides a quantitative estimate of the interval about a measured value or an experiment result within which the true value of that quantity is expected to lie. Years ago, Harry Ku of the United States National Bureau of Standards stated that ``The informational content of the statement of uncertainty determines, to a large extent, the worth of the calibrated value.`` Today, that statement is just as true about calibration or research results as it was in 1968. Why is that true? What kind of information should we include in a statement of uncertainty accompanying a calibrated value? How and where do we get the information to include in an uncertainty statement? How should we interpret and use measurement uncertainty information? This discussion will provide answers to these and other questions about uncertainty in research and in calibration. The methodology to be described has been developed by national and international groups over the past nearly thirty years, and individuals were publishing information even earlier. Yet the work is largely unknown in many science and engineering arenas. I will illustrate various aspects of uncertainty analysis with some examples drawn from the radiometry measurement and calibration discipline from research activities.

  13. Self-calibration of photometric redshift scatter in weak-lensing surveys

    SciTech Connect (OSTI)

    Zhang, Pengjie; Pen, Ue -Li; Bernstein, Gary

    2010-06-11

    Photo-z errors, especially catastrophic errors, are a major uncertainty for precision weak lensing cosmology. We find that the shear-(galaxy number) density and density-density cross correlation measurements between photo-z bins, available from the same lensing surveys, contain valuable information for self-calibration of the scattering probabilities between the true-z and photo-z bins. The self-calibration technique we propose does not rely on cosmological priors nor parameterization of the photo-z probability distribution function, and preserves all of the cosmological information available from shear-shear measurement. We estimate the calibration accuracy through the Fisher matrix formalism. We find that, for advanced lensing surveys such as the planned stage IV surveys, the rate of photo-z outliers can be determined with statistical uncertainties of 0.01-1% for z < 2 galaxies. Among the several sources of calibration error that we identify and investigate, the galaxy distribution bias is likely the most dominant systematic error, whereby photo-z outliers have different redshift distributions and/or bias than non-outliers from the same bin. This bias affects all photo-z calibration techniques based on correlation measurements. As a result, galaxy bias variations of O(0.1) produce biases in photo-z outlier rates similar to the statistical errors of our method, so this galaxy distribution bias may bias the reconstructed scatters at several-? level, but is unlikely to completely invalidate the self-calibration technique.

  14. Multivariate calibration techniques applied to NIRA (near infrared reflectance analysis) and FTIR (Fourier transform infrared) data

    SciTech Connect (OSTI)

    Long, C.L.

    1991-02-01

    Multivariate calibration techniques can reduce the time required for routine testing and can provide new methods of analysis. Multivariate calibration is commonly used with near infrared reflectance analysis (NIRA) and Fourier transform infrared (FTIR) spectroscopy. Two feasibility studies were performed to determine the capability of NIRA, using multivariate calibration techniques, to perform analyses on the types of samples that are routinely analyzed at this laboratory. The first study performed included a variety of samples and indicated that NIRA would be well-suited to perform analyses on selected materials properties such as water content and hydroxyl number on polyol samples, epoxy content on epoxy resins, water content of desiccants, and the amine values of various amine cure agents. A second study was performed to assess the capability of NIRA to perform quantitative analysis of hydroxyl numbers and water contents of hydroxyl-containing materials. Hydroxyl number and water content were selected for determination because these tests are frequently run on polyol materials and the hydroxyl number determination is time consuming. This study pointed out the necessity of obtaining calibration standards identical to the samples being analyzed for each type of polyol or other material being analyzed. Multivariate calibration techniques are frequently used with FTIR data to determine the composition of a large variety of complex mixtures. A literature search indicated many applications of multivariate calibration to FTIR data. Areas identified where quantitation by FTIR would provide a new capability are quantitation of components in epoxy and silicone resins, polychlorinated biphenyls (PCBs) in oils, and additives to polymers. 19 refs., 15 figs., 6 tabs.

  15. Calibrating DOE-2 to weather and non-weather-dependent loads for a commercial building 

    E-Print Network [OSTI]

    Bronson, John Douglas

    1992-01-01

    CALIBRATING DOE-2 TO WEATHER AND NON-WEATHER-DEPENDENT LOADS FOR A COMMERCIAL BUILDING A Thesis by JOHN DOUGLAS BRONSON Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements... for the degree of MASTER OF SCIENCE May 1992 Major Subject: Mechanical Engineering CALIBRATING DOE-2 TO WEATHER AND NON-WEATHER-DEPENDENT LOADS FOR A COMMERCIAL BUILDING A Thesis by JOHN DOUGLAS BRONSON Approved as to style and content by: M D~c Dennis...

  16. Improvements to the Rocky Flats Metrology Laboratories Velocity Meter Calibration System

    SciTech Connect (OSTI)

    Abercrombie, K.R.

    1992-03-12

    The Rocky Flats Standards Laboratory has undertaken a project to improve calibration of air velocity meters by reducing the uncertainty of the Velocity Meter Calibration System. The project was accomplished by analyzing the governing equation in order to determine which areas within the system contributed most to the overall system uncertainty. Then, based upon this new analysis, new components were selected to replace the components identified in the analysis. Finally, the system was re-evaluated to determine the new systematic uncertainty for the system.

  17. Characterization and calibration of 8-channel E-band heterodyne radiometer system for SST-1 tokamak

    SciTech Connect (OSTI)

    Siju, Varsha; Kumar, Dharmendra; Shukla, Praveena; Pathak, S. K. [Institute for Plasma Research, Bhat, Gandhinagar, Gujarat 382428 (India)] [Institute for Plasma Research, Bhat, Gandhinagar, Gujarat 382428 (India)

    2014-05-15

    An 8-channel E-band heterodyne radiometer system (74–86 GHz) is designed, characterized, and calibrated to measure the radial electron temperature profile by measuring Electron Cyclotron Emission spectrum at SST-1 Tokamak. The developed radiometer has a noise equivalent temperature of 1 eV and sensitivity of 5 × 10{sup 9} V/W. In order to precisely measure the absolute value of electron temperature, a calibration measurement of the radiometer system is performed using hot-cold Dicke switch method, which confirms the system linearity.

  18. Method and system for calibrating acquired spectra for use in spectral analysis

    DOE Patents [OSTI]

    Reber, Edward L. (Idaho Falls, ID); Rohde, Kenneth W. (Idaho Falls, ID); Blackwood, Larry G. (Bozeman, MT)

    2010-09-14

    A method for calibrating acquired spectra for use in spectral analysis includes performing Gaussian peak fitting to spectra acquired by a plurality of NaI detectors to define peak regions. A Na and annihilation doublet may be located among the peak regions. A predetermined energy level may be applied to one of the peaks in the doublet and a location of a hydrogen peak may be predicted based on the location of at least one of the peaks of the doublet. Control systems for calibrating spectra are also disclosed.

  19. In situ calibration of an infrared imaging video bolometer in the Large Helical Device

    SciTech Connect (OSTI)

    Mukai, K., E-mail: mukai.kiyofumi@LHD.nifs.ac.jp; Peterson, B. J. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292 (Japan); Pandya, S. N.; Sano, R. [The Graduate University for Advance Studies, 322-6 Oroshi-cho, Toki 509-5292 (Japan)

    2014-11-15

    The InfraRed imaging Video Bolometer (IRVB) is a powerful diagnostic to measure multi-dimensional radiation profiles in plasma fusion devices. In the Large Helical Device (LHD), four IRVBs have been installed with different fields of view to reconstruct three-dimensional profiles using a tomography technique. For the application of the measurement to plasma experiments using deuterium gas in LHD in the near future, the long-term effect of the neutron irradiation on the heat characteristics of an IRVB foil should be taken into account by regular in situ calibration measurements. Therefore, in this study, an in situ calibration system was designed.

  20. Calibration and Use of the Canberra iSolo 300G

    SciTech Connect (OSTI)

    Smith, T; Graham, C L; Sundsmo, T; Shingleton, K L

    2010-11-24

    This procedure provides instructions for the calibration and use of the Canberra iSolo Low Background Alpha/Beta Counting System (iSolo) that is used for counting air filters and swipe samples. This detector is capable of providing radioisotope identification (e.g., it can discriminate between radon daughters and plutonium). This procedure includes step-by-step instructions for: (1) Performing periodic or daily 'Background' and 'Efficiency QC' checks; (2) Setting-up the iSolo for counting swipes and air filters; (3) Counting swipes and air filters for alpha and beta activity; and (4) Annual calibration.