  1. Position paper -- Tank ventilation system design air flow rates

    SciTech Connect (OSTI)

    Goolsby, G.K.

    1995-01-04T23:59:59.000Z

    The purpose of this paper is to document a project position on required ventilation system design air flow rates for the waste storage tanks currently being designed by project W-236A, the Multi-Function Waste Tank Facility (MWTF). The Title 1 design primary tank heat removal system consists of two systems: a primary tank vapor space ventilation system; and an annulus ventilation system. At the conclusion of Title 1 design, air flow rates for the primary and annulus ventilation systems were 960 scfm and 4,400 scfm, respectively, per tank. These design flow rates were capable of removing 1,250,000 Btu/hr from each tank. However, recently completed and ongoing studies have resulted in a design change to reduce the extreme case heat load to 700,000 Btu/hr. This revision of the extreme case heat load, coupled with results of scale model evaporative testing performed by WHC Thermal Hydraulics, allow for a reduction of the design air flow rates for both primary and annulus ventilation systems. Based on the preceding discussion, ICF Kaiser Hanford Co. concludes that the design should incorporate the following design air flow rates: Primary ventilation system--500 scfm maximum and Annulus ventilation system--1,100 scfm maximum. In addition, the minimum air flow rates in the primary and annulus ventilation systems will be investigated during Title 2 design. The results of the Title 2 investigation will determine the range of available temperature control using variable air flows to both ventilation systems.

  2. THE EFFECTS OF ENERGY-EFFICIENT VENTILATION RATES ON INDOOR AIR QUALITY AT AN OHIO ELEMENTARY SCHOOL

    E-Print Network [OSTI]

    Berk, J.V.

    2013-01-01T23:59:59.000Z

    ENERGY-EFFICIENT VENTILATION RATES ON INDOOR AIR QUALITY AT AN OHIOENERGY~EFFICIENT VENTILATION RATES ON INDOOR AIR QUALITY AT AN OHIOenergy conservation opportunities i.n ten elementary schools. 1 Fairmoor Elementary School in Columbus • Ohio

  3. air ventilation rate: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Requirements University of California eScholarship Repository Summary: typical existing house. Designed passive ventilation systemsPassive Ventilation by Constant Area Vents to...

  4. Ventilation Air Preconditioning Systems

    E-Print Network [OSTI]

    Khattar, M.; Brandemuehl, M. J.

    1996-01-01T23:59:59.000Z

    simply and cost-effectively with a dual path arrangement that treats and controls the ventilation air independently of the recirculation air. The Electric Power Research Institute (EPRI)--the nonprofit R&D arm of the electric utility industry... particular type of application. EPRI is developing variations of the dual path concept to meet different reeofit and new construction markets. Figure 6. Ventilation Air Conditioner as a Separate Unit EPRVCALMAC System: Separate Unit for Ventilation Air...

  5. Quantitative relationship of sick building syndrome symptoms with ventilation rates

    E-Print Network [OSTI]

    Fisk, William J.

    2009-01-01T23:59:59.000Z

    P. Miettinen (1995). "Ventilation rate in office buildings2005). Outdoor air ventilation and work- related symptoms inand Q. H. Lei (2006). "Ventilation and performance in office

  6. Impact of Independently Controlling Ventilation Rate per Person and Ventilation

    E-Print Network [OSTI]

    1 Impact of Independently Controlling Ventilation Rate per Person and Ventilation Rate per Floor Impact of Independently Controlling Ventilation Rate per Person and Ventilation Rate per Floor Area

  7. Equivalence in Ventilation and Indoor Air Quality

    SciTech Connect (OSTI)

    Sherman, Max; Walker, Iain; Logue, Jennifer

    2011-08-01T23:59:59.000Z

    We ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum ventilation rates without taking into account the impact of those rates on IAQ. Innovative ventilation management is often a desirable element of reducing energy consumption or improving IAQ or comfort. Variable ventilation is one innovative strategy. To use variable ventilation in a way that meets standards, it is necessary to have a method for determining equivalence in terms of either ventilation or indoor air quality. This study develops methods to calculate either equivalent ventilation or equivalent IAQ. We demonstrate that equivalent ventilation can be used as the basis for dynamic ventilation control, reducing peak load and infiltration of outdoor contaminants. We also show that equivalent IAQ could allow some contaminants to exceed current standards if other contaminants are more stringently controlled.

  8. Final Report Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores in California: predicted indoor air quality and energy consumption using a matrix of ventilation scenarios

    E-Print Network [OSTI]

    Apte, Michael G.

    2013-01-01T23:59:59.000Z

    Air cleaning and local ventilation near strong sources bothair cleaning, and local ventilation may be needed at reducedremoval, air cleaning, and local ventilation may be the best

  9. INDOOR AIR QUALITY AND ENERGY EFFICIENT VENTILATION RATES AT A NEW YORK CITY ELEMENTARY SCHOOL

    E-Print Network [OSTI]

    Young, Rodger A.

    2013-01-01T23:59:59.000Z

    To determine the yearly ventilation-heating load for thecalculations of ventilation heating load 25 in variousexi~ting school heating and ventilation conditions. It must

  10. Air Distribution Effectiveness for Different Mechanical Ventilation

    E-Print Network [OSTI]

    LBNL-62700 Air Distribution Effectiveness for Different Mechanical Ventilation Systems Max H Effectiveness for Different Mechanical Ventilation Systems Max H. Sherman and Iain S. Walker Lawrence Berkeley National Laboratory, USA ABSTRACT The purpose of ventilation is to dilute indoor contaminants

  11. Impact of Independently Controlling Ventilation Rate per Person and Ventilation Rate per Floor Area on Perceived Air Quality, Sick Building Symptoms and Decision Making

    E-Print Network [OSTI]

    Maddalena, Randy

    2014-01-01T23:59:59.000Z

    REFRIGERATING AND AIR CONDITIONING ENGINEERS, 103, 244-255.Heating, Refrigerating, and Air Conditioning Engineers, Inc.REFRIGERATING AND AIR CONDITIONING ENGINEERS, 113(2), 466.

  12. THE EFFECTS OF ENERGY-EFFICIENT VENTILATION RATES ON INDOOR AIR QUALITY AT AN OHIO ELEMENTARY SCHOOL

    E-Print Network [OSTI]

    Berk, J.V.

    2013-01-01T23:59:59.000Z

    To determine the ventilation~heating load for the 2778calculations of ventilation~heating load 19 in variousthrough heating, cooling, and ventilation (see Figure l).

  13. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    SciTech Connect (OSTI)

    Rudd, A.; Bergey, D.

    2014-02-01T23:59:59.000Z

    Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

  14. Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems

    E-Print Network [OSTI]

    Sherman, Max H.

    2008-01-01T23:59:59.000Z

    6 th AIVC Conference “Ventilation Strategies and MeasurementAir Infiltration and Ventilation Centre, U.K. 1985REFERENCES ASHRAE. 2007. “Ventilation for Acceptable Indoor

  15. Equivalence in Ventilation and Indoor Air Quality

    E-Print Network [OSTI]

    Sherman, Max

    2012-01-01T23:59:59.000Z

    Equivalence in Ventilation and Indoor Air Quality M. H.have a method for determining equivalence in terms of eitherwe need to establish an equivalence principle that allows

  16. Air exchange effectiveness of conventional and task ventilation for offices

    SciTech Connect (OSTI)

    Fisk, W.J.; Faulkner, D.; Prill, R.J.

    1991-12-01T23:59:59.000Z

    Air quality and comfort complaints within large buildings are often attributed to air distribution problems. We define three air exchange effectiveness parameters related to air distribution. The first two indicate the indoor air flow pattern (i.e., the extent of short circuiting, mixing, or displacement flow) for an entire building or region. The third parameter is most useful for assessments of the spatial variability of ventilation. We also define the air diffusion effectiveness which indicates the air flow pattern within specific rooms or sections of buildings. The results of measurements of these parameters in US office buildings by the authors and other researchers are reviewed. Almost all measurements indicate very limited short circuiting or displacement flow between locations of air supply and removal. However, a moderate degree of short circuiting is evident from a few measurements in rooms with heated supply air. The results of laboratory-based measurements by the authors are consistent with the field data. Our measurements in office buildings do indicate that ventilation rates can vary substantially between indoor locations, probably due to variation in air supply rates between locations rather than variation in the indoor air flow patterns. One possible method of improving air distribution is to employ task ventilation with air supplied closer to the occupant`s breathing zone. We have evaluated two task ventilation systems in a laboratory setting. During most operating conditions, these systems did not provide a region of substantially increased ventilation where occupants breath. However, both systems are capable of providing substantially enhanced ventilation at the breathing zone under some operating conditions. Therefore, task ventilation is a potential option for using ventilation air more effectively.

  17. Air exchange effectiveness of conventional and task ventilation for offices

    SciTech Connect (OSTI)

    Fisk, W.J.; Faulkner, D.; Prill, R.J.

    1991-12-01T23:59:59.000Z

    Air quality and comfort complaints within large buildings are often attributed to air distribution problems. We define three air exchange effectiveness parameters related to air distribution. The first two indicate the indoor air flow pattern (i.e., the extent of short circuiting, mixing, or displacement flow) for an entire building or region. The third parameter is most useful for assessments of the spatial variability of ventilation. We also define the air diffusion effectiveness which indicates the air flow pattern within specific rooms or sections of buildings. The results of measurements of these parameters in US office buildings by the authors and other researchers are reviewed. Almost all measurements indicate very limited short circuiting or displacement flow between locations of air supply and removal. However, a moderate degree of short circuiting is evident from a few measurements in rooms with heated supply air. The results of laboratory-based measurements by the authors are consistent with the field data. Our measurements in office buildings do indicate that ventilation rates can vary substantially between indoor locations, probably due to variation in air supply rates between locations rather than variation in the indoor air flow patterns. One possible method of improving air distribution is to employ task ventilation with air supplied closer to the occupant's breathing zone. We have evaluated two task ventilation systems in a laboratory setting. During most operating conditions, these systems did not provide a region of substantially increased ventilation where occupants breath. However, both systems are capable of providing substantially enhanced ventilation at the breathing zone under some operating conditions. Therefore, task ventilation is a potential option for using ventilation air more effectively.

  18. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy

    SciTech Connect (OSTI)

    Sidheswaran, Meera; Destaillats, Hugo; Sullivan, Douglas P.; Fisk, William J.

    2010-10-27T23:59:59.000Z

    Approximately ten percent of the energy consumed in U.S. commercial buildings is used by HVAC systems to condition outdoor ventilation air. Reducing ventilation rates would be a simple and broadly-applicable energy retrofit option, if practical counter measures were available that maintained acceptable concentrations of indoor-generated air pollutants. The two general categories of countermeasures are: 1) indoor pollutant source control, and 2) air cleaning. Although pollutant source control should be used to the degree possible, source control is complicated by the large number and changing nature of indoor pollutant sources. Particle air cleaning is already routinely applied in commercial buildings. Previous calculations indicate that particle filtration consumes only 10percent to 25percent of the energy that would otherwise be required to achieve an equivalent amount of particle removal with ventilation. If cost-effective air cleaning technologies for volatile organic compounds (VOCs) were also available, outdoor air ventilation rates could be reduced substantially and broadly in the commercial building stock to save energy. The research carried out in this project focuses on developing novel VOC air cleaning technologies needed to enable energy-saving reductions in ventilation rates. The minimum required VOC removal efficiency to counteract a 50percent reduction in ventilation rate for air cleaning systems installed in the HVAC supply airstream is modest (generally 20percent or less).

  19. Ventilation and Air Quality in Indoor Ice Skating Arenas Chunxin Yang, Ph.D.1

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    Ventilation and Air Quality in Indoor Ice Skating Arenas Chunxin Yang, Ph.D.1 Philip Demokritou, and the operation strategy of the ventilation system are significant contributing factors to the indoor air quality exchange rate, air distribution method, and ventilation control strategies on the IAQ in an arena. With CFD

  20. Heating, Ventilating, and Air-Conditioning: Recent Advances in Diagnostics and Controls to Improve Air-Handling System Performance

    E-Print Network [OSTI]

    Wray, Craig P.

    2008-01-01T23:59:59.000Z

    Heating, Ventilating, and Air-Conditioning: Recent Advancesthe energy efficiency of many heating, ventilating, and air-system, which delivers heating, cooling, and ventilation air

  1. Risk Factors in Heating, Ventilating, and Air-Conditioning Systems for Occupant Symptoms in

    E-Print Network [OSTI]

    Mendell, M.J.; Lei-Gomez, Q.; Mirer, A.; Seppanen, O.; Brunner, G.

    2007-01-01T23:59:59.000Z

    LBNL-61870 Risk Factors in Heating, Ventilating, and Air-for Occupant Symptoms in Heating, Ventilating, and Air-uncertain. Characteristics of heating, ventilating, and air-

  2. BUILDING VENTILATION AND INDOOR AIR QUALITY PROGRAM. CHAPTER FROM ENERGY AND ENVIRONMENT DIVISION ANNUAL REPORT 1978

    E-Print Network [OSTI]

    Cairns, Elton J.

    2011-01-01T23:59:59.000Z

    occupants. The heating, ventilation and air conditioning (third of the heating, ventilation, and air conditioning (see Fig. 1) Heating ventilation and air conditioning (HVAC)

  3. Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems

    E-Print Network [OSTI]

    Wetter, Michael

    2010-01-01T23:59:59.000Z

    for Building Heating, Ventilation and Air-Conditioningfor Building Heating, Ventilation and Air-Conditioningfor building heating, ventilation and air con- ditioning

  4. Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems

    E-Print Network [OSTI]

    Sherman, Max H.

    2008-01-01T23:59:59.000Z

    In Review J. Indoor Air) 2007 LBNL-63193 Tarantola, Albert,Gas Measurement to Determine Air Movements in a House,Measurement Techniques”, Air Infiltration and Ventilation

  5. Indoor Air Quality and Ventilation in Residential Deep Energy Retrofits

    SciTech Connect (OSTI)

    Less, Brennan; Walker, Iain

    2014-06-01T23:59:59.000Z

    Because airtightening is a significant part of Deep Energy Retrofits (DERs), concerns about ventilation and Indoor Air Quality (IAQ) have emerged. To investigate this, ventilation and IAQ were assessed in 17 non-smoking California Deep Energy Retrofit homes. Inspections and surveys were used to assess household activities and ventilation systems. Pollutant sampling performed in 12 homes included six-day passive samples of nitrogen dioxide (NO2), formaldehyde and air exchange rate (AER); time-resolved data loggers were used to measure particle counts. Half of the homes provided continuous mechanical ventilation. Despite these homes being twice as airtight (3.0 and 7.6 ACH50, respectively), their median AER was indistinguishable from naturally vented homes (0.36 versus 0.37 hr--1). Numerous problems were found with ventilation systems; however, pollutant levels did not reach levels of concern in most homes. Ambient NO2 standards were exceeded in some gas cooking homes that used legacy ranges with standing pilots, and in Passive House-style homes without range hoods exhausted to outside. Cooking exhaust systems were installed and used inconsistently. The majority of homes reported using low-emitting materials, and formaldehyde levels were approximately half those in conventional new CA homes (19.7 versus 36 ?g/m3), with emissions rates nearly 40percent less (12.3 versus 20.6 ?g/m2/hr.). Presence of air filtration systems led to lower indoor particle number concentrations (PN>0.5: 8.80E+06 PN/m3 versus 2.99E+06; PN>2.5: 5.46E+0.5 PN/m3 versus 2.59E+05). The results indicate that DERs can provide adequate ventilation and IAQ, and that DERs should prioritize source control, particle filtration and well-designed local exhaust systems, while still providing adequate continuous ventilation.

  6. Equivalence in Ventilation and Indoor Air Quality

    E-Print Network [OSTI]

    Sherman, Max

    2012-01-01T23:59:59.000Z

    event, the intermittent ventilation equations of Sherman,of the energy impact of ventilation and associated financialReview of Residential Ventilation Technologies. Berkeley,

  7. Equivalence in Ventilation and Indoor Air Quality

    E-Print Network [OSTI]

    Sherman, Max

    2012-01-01T23:59:59.000Z

    the use of mechanical ventilation systems in the same way asand operating ventilation systems with variable amounts ofto determine the ventilation system’s operation. We presume

  8. Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems

    SciTech Connect (OSTI)

    Sherman, Max; Sherman, Max H.; Walker, Iain S.

    2008-05-01T23:59:59.000Z

    The purpose of ventilation is dilute or remove indoor contaminants that an occupant is exposed to. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. Most US homes have central HVAC systems, which tend to mix the air thus the indoor conditions between zones. Different types of ventilation systems will provide different amounts of exposure depending on the effectiveness of their air distribution systems and the location of sources and occupants. This paper will report on field measurements using a unique multi-tracer measurement system that has the capacity to measure not only the flow of outdoor air to each zone, but zone-to-zone transport. The paper will derive seven different metrics for the evaluation of air distribution. Measured data from two homes with different levels of natural infiltration will be used to evaluate these metrics for three different ASHRAE Standard 62.2 compliant ventilation systems. Such information can be used to determine the effectiveness of different systems so that appropriate adjustments can be made in residential ventilation standards such as ASHRAE Standard 62.2.

  9. STATE OF CALIFORNIA INDOOR AIR QUALITY AND MECHANICAL VENTILATION

    E-Print Network [OSTI]

    STATE OF CALIFORNIA INDOOR AIR QUALITY AND MECHANICAL VENTILATION CEC- CF-6R-MECH-05 (Revised 08 Ventilation (Page 1 of 7) Site Address: Enforcement Agency: Permit Number: 2008 Residential Compliance Forms August 2009 Ventilation for Indoor Air Quality (IAQ): All dwelling units shall meet the requirements

  10. Final Report Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores in California: predicted indoor air quality and energy consumption using a matrix of ventilation scenarios

    E-Print Network [OSTI]

    Apte, Michael G.

    2013-01-01T23:59:59.000Z

    evaluation of displacement ventilation and dedicated outdoorB, Carlson N (2009). Ventilation requirements in a retailof Intermittent Ventilation for Providing Acceptable Indoor

  11. Room air stratification in combined chilled ceiling and displacement ventilation systems.

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred; Tully, Brad; Rimmer, Julian

    2012-01-01T23:59:59.000Z

    nodal model for displacement ventilation and chilled ceiling2002. Displacement ventilation in non- industrial premises.ceiling/displacement ventilation hybrid air conditioning

  12. Assessment of Indoor Air Quality Benefits and Energy Costs of Mechanical Ventilation

    E-Print Network [OSTI]

    Logue, J.M.

    2012-01-01T23:59:59.000Z

    Energy Costs of Mechanical Ventilation KEMA-XENERGY.2004.Offermann, F. J.2009. Ventilation and indoor air quality intowards meeting residential ventilation needs. Berkeley, CA,

  13. AIR FLOW MODELING IN DEEP WELLS: APPLICATION TO MINING VENTILATION

    E-Print Network [OSTI]

    Johansson, Karl Henrik

    AIR FLOW MODELING IN DEEP WELLS: APPLICATION TO MINING VENTILATION E. WITRANT1, K.H. JOHANSSON2. Introduction Traditionally, the control of large-scale systems, such as mining ventilation, has been performed to the preliminary design of the global system and automation devices. Mining ventilation provides for an interesting

  14. AIR FLOW MODELING IN DEEP WELLS: APPLICATION TO MINING VENTILATION

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    AIR FLOW MODELING IN DEEP WELLS: APPLICATION TO MINING VENTILATION E. WITRANT1, K.H. JOHANSSON2, the control of large-scale systems, such as mining ventilation, has been performed locally with decentralized of the global system and automation devices. Mining ventilation provides for an interesting exam- ple

  15. OCCUPANT-GENERATED CO2 AS AN INDICATOR OF VENTILATION RATE

    E-Print Network [OSTI]

    Turiel, Isaac

    2012-01-01T23:59:59.000Z

    ln mechanical ventilation systems are often inconvenientlywas conducted, the ventilation system mixes outside air withon a day when the ventilation system was in the all-outside-

  16. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy ? FY11 Final Report

    SciTech Connect (OSTI)

    Sidheswaran, Meera; Destaillats, Hugo; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William J.

    2011-10-31T23:59:59.000Z

    The research carried out in this project focuses on developing novel volatile organic compounds (VOCs) air cleaning technologies needed to enable energy-saving reductions in ventilation rates. we targeted a VOC air cleaning system that could enable a 50% reduction in ventilation rates. In a typical commercial HVAC system that provides a mixture of recirculated and outdoor air, a VOC air cleaner in the supply airstream must have a 15% to 20% VOC removal efficiency to counteract a 50% reduction in outdoor air supply.

  17. Equivalence in Ventilation and Indoor Air Quality

    E-Print Network [OSTI]

    Sherman, Max

    2012-01-01T23:59:59.000Z

    dryers, and other local ventilation. ? Occupant activitiesventilation such as that provided by economizers or intermittent locallocal kitchen and bath exhausts, but a large part of the standard focuses on the continuous mechanical whole-house ventilation.

  18. Preconditioning Outside Air: Cooling Loads from Building Ventilation

    E-Print Network [OSTI]

    Kosar, D.

    1998-01-01T23:59:59.000Z

    HVAC equipment manufacturers, specifiers and end users interacting in the marketplace today are only beginning to address the series of issues promulgated by the increased outside air requirements in ASHRAE Standard 62- 1989, "Ventilation...

  19. Capture and Use of Coal Mine Ventilation Air Methane

    SciTech Connect (OSTI)

    Deborah Kosmack

    2008-10-31T23:59:59.000Z

    CONSOL Energy Inc., in conjunction with MEGTEC Systems, Inc., and the U.S. Department of Energy with the U.S. Environmental Protection Agency, designed, built, and operated a commercial-size thermal flow reversal reactor (TFRR) to evaluate its suitability to oxidize coal mine ventilation air methane (VAM). Coal mining, and particularly coal mine ventilation air, is a major source of anthropogenic methane emissions, a greenhouse gas. Ventilation air volumes are large and the concentration of methane in the ventilation air is low; thus making it difficult to use or abate these emissions. This test program was conducted with simulated coal mine VAM in advance of deploying the technology on active coal mine ventilation fans. The demonstration project team installed and operated a 30,000 cfm MEGTEC VOCSIDIZER oxidation system on an inactive coal mine in West Liberty, WV. The performance of the unit was monitored and evaluated during months of unmanned operation at mostly constant conditions. The operating and maintenance history and how it impacts the implementation of the technology on mine fans were investigated. Emission tests showed very low levels of all criteria pollutants at the stack. Parametric studies showed that the equipment can successfully operate at the design specification limits. The results verified the ability of the TFRR to oxidize {ge}95% of the low and variable concentration of methane in the ventilation air. This technology provides new opportunities to reduce greenhouse gas emissions by the reduction of methane emissions from coal mine ventilation air. A large commercial-size installation (180,000 cfm) on a single typical mine ventilation bleeder fan would reduce methane emissions by 11,000 to 22,100 short tons per year (the equivalent of 183,000 to 366,000 metric tonnes carbon dioxide).

  20. Air Distribution Effectiveness for Residential Mechanical Ventilation: Simulation and Comparison of Normalized Exposures

    SciTech Connect (OSTI)

    Petithuguenin, T.D.P.; Sherman, M.H.

    2009-05-01T23:59:59.000Z

    The purpose of ventilation is to dilute indoor contaminants that an occupant is exposed to. Even when providing the same nominal rate of outdoor air, different ventilation systems may distribute air in different ways, affecting occupants' exposure to household contaminants. Exposure ultimately depends on the home being considered, on source disposition and strength, on occupants' behavior, on the ventilation strategy, and on operation of forced air heating and cooling systems. In any multi-zone environment dilution rates and source strengths may be different in every zone and change in time, resulting in exposure being tied to occupancy patterns.This paper will report on simulations that compare ventilation systems by assessing their impact on exposure by examining common house geometries, contaminant generation profiles, and occupancy scenarios. These simulations take into account the unsteady, occupancy-tied aspect of ventilation such as bathroom and kitchen exhaust fans. As most US homes have central HVAC systems, the simulation results will be used to make appropriate recommendations and adjustments for distribution and mixing to residential ventilation standards such as ASHRAE Standard 62.2.This paper will report on work being done to model multizone airflow systems that are unsteady and elaborate the concept of distribution matrix. It will examine several metrics for evaluating the effect of air distribution on exposure to pollutants, based on previous work by Sherman et al. (2006).

  1. ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality in Low- Rise Residential Buildings - Building America Top Innovation ASHRAE Standard 62.2. Ventilation and...

  2. Energy analysis of a personalized ventilation system in a cold climate: influence of the supplied air temperature

    E-Print Network [OSTI]

    Schiavon, Stefano; Melikov, Arsen

    2008-01-01T23:59:59.000Z

    potential of personalized ventilation system in the tropics.a chair-based personalized ventilation system. Building andedged-mounted task ventilation system. Indoor Air, Vol. 14 (

  3. A Survey and Critical Review of the Literature on Indoor Air Quality, Ventilation and Health Symptoms in Schools

    E-Print Network [OSTI]

    Daisey, Joan M.

    2010-01-01T23:59:59.000Z

    is experiencing IAQ and ventilation problems, and relatedis experiencing IAQ and ventilation problems, and relatedof air quality and ventilation problems in California

  4. An Index for Evaluation of Air Quality Improvement in Rooms with Personalized Ventilation Based on Occupied Density and Normalized Concentration

    E-Print Network [OSTI]

    Schiavon, Stefano; Melikov, Arsen; Cermak, Radim; De Carli, Michele; Li, Xianting

    2007-01-01T23:59:59.000Z

    Journal of heating, Ventilation and Refrigeration Research,on Cold Climate, Heating, Ventilation and Air-Conditioning,

  5. Room air stratification in combined chilled ceiling and displacement ventilation systems.

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred; Tully, Brad; Rimmer, Julian

    2012-01-01T23:59:59.000Z

    Environments. Proceedings of Indoor Air 2005: 10 thInternational Conference on Indoor Air Quality and Climate,displacement ventilation hybrid air conditioning system-

  6. Transpired Solar Collector at NREL's Waste Handling Facility Uses Solar Energy to Heat Ventilation Air (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2010-09-01T23:59:59.000Z

    The transpired solar collector was installed on NREL's Waste handling Facility (WHF) in 1990 to preheat ventilation air. The electrically heated WHF was an ideal candidate for the this technology - requiring a ventilation rate of 3,000 cubic feet per meter to maintain safe indoor conditions.

  7. A web based CBR system for heating ventilation and air conditioning systems sales support

    E-Print Network [OSTI]

    Watson, Ian

    A web based CBR system for heating ventilation and air conditioning systems sales support D describes the implementation of a case-based reasoning (CBR) system to support heating ventilation and air. Introduction Western Air is a distributor of heating ventilation and air conditioning (HVAC) systems

  8. OCCUPANT-GENERATED CO2 AS AN INDICATOR OF VENTILATION RATE

    E-Print Network [OSTI]

    Turiel, Isaac

    2012-01-01T23:59:59.000Z

    1977. 7. Hunt, C.M. , "Ventilation Measurements in theJ. , and Hollowell, C.D. , Ventilation on Indoor Quality inThe Effect of Reduced Ventilation on Indoor Air Quality And

  9. Are Ventilation Filters Degrading Indoor Air Quality in California Classrooms?

    SciTech Connect (OSTI)

    Fisk, William J.; Destaillats, H.; Apte, M.G.; Destaillats,, Hugo; Fisk, Michael G. Apte and William J.

    2008-10-01T23:59:59.000Z

    Heating, ventilating, and cooling classrooms in California consume substantial electrical energy. Indoor air quality (IAQ) in classrooms affects studenthealth and performance. In addition to airborne pollutants that are emitted directly by indoor sources and those generated outdoors, secondary pollutants can be formed indoors by chemical reaction of ozone with other chemicals and materials. Filters are used in nearly all classroom heating, ventilation and air?conditioning (HVAC) systems to maintain energy-efficient HVAC performance and improve indoor air quality; however, recent evidence indicates that ozone reactions with filters may, in fact, be a source of secondary pollutants. This project quantitatively evaluated ozone deposition in HVAC filters and byproduct formation, and provided a preliminary assessment of the extent towhich filter systems are degrading indoor air quality. The preliminary information obtained will contribute to the design of subsequent research efforts and the identification of energy efficient solutions that improve indoor air quality in classrooms and the health and performance of students.

  10. A Survey and Critical Review of the Literature on Indoor Air Quality, Ventilation and Health Symptoms in Schools

    E-Print Network [OSTI]

    Daisey, Joan M.

    2010-01-01T23:59:59.000Z

    rate over- estimates the local ventilation rate of occupied1992); no local exhaust ventilation for photocopiers that

  11. Should Title 24 Ventilation Requirements Be Amended to include an Indoor Air Quality Procedure?

    SciTech Connect (OSTI)

    Dutton, Spencer M.; Mendell, Mark J.; Chan, Wanyu R.

    2013-05-13T23:59:59.000Z

    Minimum outdoor air ventilation rates (VRs) for buildings are specified in standards, including California?s Title 24 standards. The ASHRAE ventilation standard includes two options for mechanically-ventilated buildings ? a prescriptive ventilation rate procedure (VRP) that specifies minimum VRs that vary among occupancy classes, and a performance-based indoor air quality procedure (IAQP) that may result in lower VRs than the VRP, with associated energy savings, if IAQ meeting specified criteria can be demonstrated. The California Energy Commission has been considering the addition of an IAQP to the Title 24 standards. This paper, based on a review of prior data and new analyses of the IAQP, evaluates four future options for Title 24: no IAQP; adding an alternate VRP, adding an equivalent indoor air quality procedure (EIAQP), and adding an improved ASHRAE-like IAQP. Criteria were established for selecting among options, and feedback was obtained in a workshop of stakeholders. Based on this review, the addition of an alternate VRP is recommended. This procedure would allow lower minimum VRs if a specified set of actions were taken to maintain acceptable IAQ. An alternate VRP could also be a valuable supplement to ASHRAE?s ventilation standard.

  12. Worker productivity and ventilation rate in a call center: Analyses of time-series data for a group of workers

    SciTech Connect (OSTI)

    Fisk, William J.; Price, Phillip; Faulkner, David; Sullivan, Douglas; Dibartolomeo, Dennis; Federspiel, Cliff; Liu, Gang; Lahiff, Maureen

    2002-01-01T23:59:59.000Z

    In previous studies, increased ventilation rates and reduced indoor carbon dioxide concentrations have been associated with improvements in health at work and increased performance in work-related tasks. Very few studies have assessed whether ventilation rates influence performance of real work. This paper describes part one of a two-part analysis from a productivity study performed in a call center operated by a health maintenance organization. Outside air ventilation rates were manipulated, indoor air temperatures, humidities, and carbon dioxide concentrations were monitored, and worker performance data for advice nurses, with 30-minute resolution, were analyzed via multivariate linear regression to look for an association of performance with building ventilation rate, or with indoor carbon dioxide concentration (which is related to ventilation rate per worker). Results suggest that the effect of ventilation rate on worker performance in this call center was very small (probably less than 1%) or nil, over most of the range of ventilation rate experienced during the study (roughly 12 L s{sup -1} to 48 L s{sup -1} per person). However, there is some evidence suggesting performance improvements of 2% or more when the ventilation rate per person is very high, as indicated by indoor CO{sub 2} concentrations exceeding outdoor concentrations by less than 75 ppm.

  13. Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems

    E-Print Network [OSTI]

    Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems Michael Wetter available Modelica library for building heating, ventilation and air conditioning systems. The library development is focused on the develop- ment of models for building heating, ventilation and air

  14. Air flow and particle control with different ventilation systems in a classroom

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    Air flow and particle control with different ventilation systems in a classroom Sture Holmberg, Ph@mit.edu Phone: +1-617-253-7714, Fax: +1-617-2536152 Abstract Most ventilation and air conditioning systems. For displacement ventilation systems, designers normally assume that all pollutants follow the buoyant air flow

  15. Final Report Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores in California: predicted indoor air quality and energy consumption using a matrix of ventilation scenarios

    E-Print Network [OSTI]

    Apte, Michael G.

    2013-01-01T23:59:59.000Z

    irritant effects. For energy models, we estimated buildingreduced outdoor air VRs. The energy models estimate that, inof commercial building energy models. The study assessed the

  16. Field Test of Room-to-Room Distribution of Outside Air with Two Residential Ventilation Systems

    SciTech Connect (OSTI)

    Hendron, R.; Anderson, R.; Barley, D.; Rudd, A.; Townsend, A.; Hancock, E.

    2008-08-01T23:59:59.000Z

    Uniform distribution of outside air is one way to ensure that residential dilution ventilation systems will provide a known amount of fresh air to all rooms.

  17. Modeling indoor exposures to VOCs and SVOCs as ventilation rates vary

    E-Print Network [OSTI]

    Parthasarathy, Srinandini

    2013-01-01T23:59:59.000Z

    J. 2008. Analysis of ventilation data from the United StatesASHRAE Standard 62.1-2010, Ventilation for Acceptable Indoorto VOCs and   SVOCs as ventilation rates vary   Srinandini 

  18. Prediction of Room Air Diffusion for Reduced Diffuser Flow Rates 

    E-Print Network [OSTI]

    Gangisetti, Kavita

    2011-02-22T23:59:59.000Z

    and analytical tool for investigating ventilation inside the system and thus to increase thermal comfort and improve indoor air quality. The room air supply diffuser flow rates can be reduced for less loading with the help of a variable air volume unit...

  19. AUTOMATIC VARIABLE VENTILATION CONTROL SYSTEMS BASED ON AIR QUALITY DETECTION

    E-Print Network [OSTI]

    Turiel, Isaac

    2011-01-01T23:59:59.000Z

    saon Automatic Variable Ventilation Control Systems Based onL Kusuda, "Control Ventilation to Conserve Energy While t·79-3 Automatic variable ventilation control systems based on

  20. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy

    E-Print Network [OSTI]

    Sidheswaran, Meera

    2010-01-01T23:59:59.000Z

    VOCs substitute for ventilation in commercial buildings? ."Gorfain J (2008). Analysis of ventilation data from the U.S.Commercial Building Ventilation Energy Meera Sidheswaran,

  1. AUTOMATIC VARIABLE VENTILATION CONTROL SYSTEMS BASED ON AIR QUALITY DETECTION

    E-Print Network [OSTI]

    Turiel, Isaac

    2011-01-01T23:59:59.000Z

    SUt1t1ARY Mechanical ventilation systems usually provide aof any 02 based ventilation system is that a ventilationwith type of ventilation system~ weather conditions, and

  2. AUTOMATIC VARIABLE VENTILATION CONTROL SYSTEMS BASED ON AIR QUALITY DETECTION

    E-Print Network [OSTI]

    Turiel, Isaac

    2011-01-01T23:59:59.000Z

    ~saon Automatic Variable Ventilation Control Systems Based79-3 Automatic variable ventilation control systems based onof automatic variable ventilation control systems, result in

  3. The Ocean's Memory of the Atmosphere: Residence-Time and Ventilation-Rate Distributions of Water Masses

    E-Print Network [OSTI]

    Primeau, Francois W; Holzer, Mark

    2006-01-01T23:59:59.000Z

    in steady state. Local ventilation rates for non- steadyrespec- tively. The local ventilation fluxes regardless ofmaps of ventilation The residence-time-partitioned, local

  4. Cost effective combined axial fan and throttling valve control of ventilation rate

    E-Print Network [OSTI]

    Sengun, Mehmet Haluk

    Cost effective combined axial fan and throttling valve control of ventilation rate C.J. Taylor 1 P with Proportional-Integral-Plus (PIP) control of ventilation rate in mechanically ventilated agricultural buildings ventilation. The new combined fan/valve configuration is compared with a commercially available PID

  5. CAN SORBENT-BASED GAS PHASE AIR CLEANING FOR VOCS SUBSTITUTE FOR VENTILATION IN COMMERCIAL BUILDINGS?

    SciTech Connect (OSTI)

    Fisk, William; Fisk, William J.

    2007-08-01T23:59:59.000Z

    This paper reviews current knowledge about the suitability of sorbent-based air cleaning for removing volatile organic compounds (VOCs) from the air in commercial buildings, as needed to enable reductions in ventilation rates and associated energy savings. The principles of sorbent air cleaning are introduced, criteria are suggested for sorbent systems that can counteract indoor VOC concentration increases from reduced ventilation, major findings from research on sorbent performance for this application are summarized, and related priority research needs are identified. Major conclusions include: sorbent systems can remove a broad range of VOCs with moderate to high efficiency, sorbent technologies perform effectively when challenged with VOCs at the low concentrations present indoors, and there is a large uncertainty about the lifetime and associated costs of sorbent air cleaning systems when used in commercial buildings for indoor VOC control. Suggested priority research includes: experiments to determine sorbent system VOC removal efficiencies and lifetimes considering the broad range and low concentration of VOCs indoors; evaluations of in-situ regeneration of sorbents; and an updated analysis of the cost of sorbent air cleaning relative to the cost of ventilation.

  6. Assessment of organic compound exposures, thermal comfort parameters, and HVAC system-driven air exchange rates in public school portable classrooms in California

    E-Print Network [OSTI]

    Shendell, Derek Garth

    2010-01-01T23:59:59.000Z

    exposures and heating, ventilation, and air conditioningexposures and heating, ventilation, and air conditioningexposures and heating, ventilation, and air conditioning

  7. BUILDING VENTILATION AND INDOOR AIR QUALITY PROGRAM. CHAPTER FROM ENERGY AND ENVIRONMENT DIVISION ANNUAL REPORT 1978

    E-Print Network [OSTI]

    Cairns, Elton J.

    2011-01-01T23:59:59.000Z

    ventilation rates established by various state and localVentilation requirements are currently set by state and localventilation rates are specified in the various building codes adopted by state and local

  8. An ASAE/CSAE Meeting Presentation Paper Number: 044177 Comparison of Direct vs. Indirect Ventilation Rate

    E-Print Network [OSTI]

    Kentucky, University of

    Ventilation Rate Determination for Manure Belt Laying Hen Houses Hong Li Hongwei Xin Yi Liang Graduate. Direct measurement of ventilation rate in livestock housing can be a formidable task due a potentially viable, more flexible alternative to estimating ventilation rate. The reliability of CO2 balance

  9. Submitted to Building and Environment ON ESTIMATION OF MULTIZONE VENTILATION RATES

    E-Print Network [OSTI]

    LBL-25772 Submitted to Building and Environment ON ESTIMATION OF MULTIZONE VENTILATION RATES FROM techniques are becoming widely used to measure the ventilation rates in buildings. As more detailed describes tech- niques for improving tracer-gas derived ventilation data using physical knowledge about

  10. Hospital ventilation standards and energy conservation: chemical contamination of hospital air. Final report

    SciTech Connect (OSTI)

    Rainer, D.; Michaelsen, G.S.

    1980-03-01T23:59:59.000Z

    In an era of increasing energy conservation consciousness, a critical reassessment of the validity of hospital ventilation and thermal standards is made. If current standards are found to be excessively conservative, major energy conservation measures could be undertaken by rebalancing and/or modification of current HVAC systems. To establish whether or not reducing ventilation rates would increase airborne chemical contamination to unacceptable levels, a field survey was conducted to develop an inventory and dosage estimates of hospital generated airborne chemical contaminants to which patients, staff, and visitors are exposed. The results of the study are presented. Emphasis is on patient exposure, but an examination of occupational exposure was also made. An in-depth assessment of the laboratory air environment is documented. Housekeeping products used in survey hospitals, hazardous properties of housekeeping chemicals and probable product composition are discussed in the appendices.

  11. Adjudication Concerning the Contract for the Maintenance of Pipework and Heating, Ventilating and Air-Conditioning Installations

    E-Print Network [OSTI]

    1971-01-01T23:59:59.000Z

    Adjudication Concerning the Contract for the Maintenance of Pipework and Heating, Ventilating and Air-Conditioning Installations

  12. Adjudication of a Contract for the Maintenance of Pipework and Heating, Ventilating and Air-Conditioning Installations

    E-Print Network [OSTI]

    1977-01-01T23:59:59.000Z

    Adjudication of a Contract for the Maintenance of Pipework and Heating, Ventilating and Air-Conditioning Installations

  13. Proposed Adjudication of the Contract for the Heating, Ventilating and Air Conditioning Installations for the ISR Buildings

    E-Print Network [OSTI]

    1968-01-01T23:59:59.000Z

    Proposed Adjudication of the Contract for the Heating, Ventilating and Air Conditioning Installations for the ISR Buildings

  14. Numerical Analysis of the Channel Wheel Fresh Air Ventilator Under Frosting Conditions

    E-Print Network [OSTI]

    Gao, B.; Dong, Z.; Cheng, Z.; Luo, E.

    2006-01-01T23:59:59.000Z

    As new equipment, the channel wheel fresh air ventilator has become increasingly popular in recent years. However, when such equipment is operated under low ambient temperature in the freezing area in winter, the formation of frost on the outdoor...

  15. Demand Controlled Ventilation and Classroom Ventilation

    E-Print Network [OSTI]

    Fisk, William J.

    2014-01-01T23:59:59.000Z

    to districts for ventilation, heating, and cooling.   Thus G is the gas use for heating ventilation  air, G i  is the air  gas use for heating ventilation air  the time elapsed 

  16. Evaluation of an Incremental Ventilation Energy Model for Estimating Impacts of Air Sealing and Mechanical Ventilation

    E-Print Network [OSTI]

    Logue, Jennifer M.

    2014-01-01T23:59:59.000Z

    Calculation 8th Edition, Air Conditioning Contractors ofArlington, VA, Air-Conditioning, Heating and RefrigerationRefrigerating and Air Conditioning Engineers. Standard 136.

  17. A simplified model for estimating population-scale energy impacts of building envelope air-tightening and mechanical ventilation retrofits

    SciTech Connect (OSTI)

    Logue, J. M.; Turner, W. J.N.; Walker, I. S.; Singer, B. C.

    2015-01-01T23:59:59.000Z

    Changing the air exchange rate of a home (the sum of the infiltration and mechanical ventilation airflow rates) affects the annual thermal conditioning energy. Large-scale changes to air exchange rates of the housing stock can significantly alter the residential sector's energy consumption. However, the complexity of existing residential energy models is a barrier to the accurate quantification of the impact of policy changes on a state or national level. The Incremental Ventilation Energy (IVE) model developed in this study combines the output of simple air exchange models with a limited set of housing characteristics to estimate the associated change in energy demand of homes. The IVE model was designed specifically to enable modellers to use existing databases of housing characteristics to determine the impact of ventilation policy change on a population scale. The IVE model estimates of energy change when applied to US homes with limited parameterisation are shown to be comparable to the estimates of a well-validated, complex residential energy model.

  18. Demand Controlled Ventilation and Classroom Ventilation

    E-Print Network [OSTI]

    Fisk, William J.

    2014-01-01T23:59:59.000Z

    2 -based demand controlled ventilation using ASHRAE Standardoptimizing energy use and ventilation. ASHRAE TransactionsWJ, Grimsrud DT, et al. 2011. Ventilation rates and health:

  19. Demand Controlled Ventilation and Classroom Ventilation

    E-Print Network [OSTI]

    Fisk, William J.

    2014-01-01T23:59:59.000Z

    use of demand control ventilation systems in general officedemand controlled  ventilation systems, Dennis DiBartolomeo the demand controlled ventilation system increased the rate 

  20. Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems

    E-Print Network [OSTI]

    Sherman, Max H.

    2008-01-01T23:59:59.000Z

    credit for different air distribution methods can be given.Measured Air Distribution Effectiveness for Residential4   Distribution metric

  1. Energy and air quality implications of passive stack ventilation in residential buildings

    E-Print Network [OSTI]

    Energy and air quality implications of passive stack ventilation in residential buildings Laboratory is an equal opportunity employer. #12;Energy and air quality implications of passive stack in residential buildings and compliance is normally achieved with fully mechanical whole-house systems; however

  2. Should Title 24 Ventilation Requirements Be Amended to

    E-Print Network [OSTI]

    Should Title 24 Ventilation Requirements Be Amended to include an Indoor Air Quality Procedure Ventilation Requirements Be Amended to include an Indoor Air Quality Procedure? William J. Fisk, Spencer M Berkeley, CA 94720 May 10, 2013 ABSTRACT Minimum outdoor air ventilation rates (VRs) for buildings

  3. Healthy Zero Energy Buildings (HZEB) Program - Cross-Sectional Study of Contaminant Levels, Source, Strengths, and Ventilation Rates in Retail Stores

    SciTech Connect (OSTI)

    Chan, Wanyu R.; Sidheswaran, Meera; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William

    2014-02-01T23:59:59.000Z

    This field study measured ventilation rates and indoor air quality parameters in 21 visits to retail stores in California. The data was collected to guide the development of new, science-based commercial building ventilation rate standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. Data collection occurred between September 2011 and March 2013. Three types of stores participated in this study: grocery stores, furniture/hardware stores, and apparel stores. Ventilation rates and indoor air contaminant concentrations were measured on a weekday, typically between 9 am and 6 pm. Ventilation rates measured using a tracer gas decay method exceeded the minimum requirement of California’s Title 24 Standard in all but one store. Even though there was adequate ventilation according to Title 24, concentrations of formaldehyde, acetaldehyde, and acrolein exceeded the most stringent chronic health guidelines. Other indoor air contaminants measured included carbon dioxide (CO{sub 2}), carbon monoxide (CO), ozone (O{sub 3}), and particulate matter (PM). Concentrations of CO{sub 2} were kept low by adequate ventilation, and were assumed low also because the sampling occurred on a weekday when retail stores were less busy. CO concentrations were also low. The indoor-outdoor ratios of O{sub 3} showed that the first-order loss rate may vary by store trade types and also by ventilation mode (mechanical versus natural). Analysis of fine and ultrafine PM measurements showed that a substantial portion of the particle mass in grocery stores with cooking-related emissions was in particles less than 0.3 ?m. Stores without cooking as an indoor source had PM size distributions that were more similar indoors and outdoors. The whole-building emission rates of volatile organic compounds (VOCs) and PM were estimated from the measured ventilation rates and indoor and outdoor contaminant concentrations. Mass balance models were then used to determine the ventilation rates, filtration strategies, or source reductions needed to maintain indoor contaminant concentrations below reference levels. Several scenarios of potential concern were considered: (i) formaldehyde levels in furniture/hardware stores, (ii) contaminants associated with cooking (e.g., PM, acrolein, and acetaldehyde) in grocery stores, and (iii) outdoor contaminants (e.g., PM and O{sub 3}) impacting stores that use natural ventilation. Estimated formaldehyde emission rates suggest that retail stores would need to ventilate at levels far exceeding the current Title 24 requirement to lower indoor concentrations below California’s stringent formaldehyde reference level. Given the high costs of providing ventilation but only modest chronic health benefit is expected, effective source control is an attractive alternative, as demonstrated by some retail stores in this study. Predictions showed that grocery stores need MERV 13 air filters, instead of MERV 8 filters that are more commonly used, to maintain indoor PM at levels that meet the chronic health standards for PM. Exposure to acrolein is a potential health concern in grocery stores, and should be addressed by increasing the use of kitchen range hoods or improving their contaminant removal efficiency. In stores that rely on natural ventilation, indoor PM can be a health concern if the stores are located in areas with high outdoor PM. This concern may be addressed by switching to mechanical ventilation when the outdoor air quality is poor, while continuing natural ventilation when outdoor air quality is good.

  4. Air change effectiveness in laboratory tests of combined chilled ceiling and displacement ventilation.

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred; Tully, Brad; Rimmer, Julian

    2011-01-01T23:59:59.000Z

    for Displacement Ventilation. Atlanta: ASHRAE. ISO. 1993.ceiling and displacement ventilation systems. Energy andceiling and displacement ventilation systems. Submitted to

  5. Assessment of Indoor Air Quality Benefits and Energy Costs of Mechanical Ventilation

    SciTech Connect (OSTI)

    Logue, J.M.; Price, P.N.; Sherman, M.H.; Singer, B.C.

    2011-07-01T23:59:59.000Z

    Intake of chemical air pollutants in residences represents an important and substantial health hazard. Sealing homes to reduce air infiltration can save space conditioning energy, but can also increase indoor pollutant concentrations. Mechanical ventilation ensures a minimum amount of outdoor airflow that helps reduce concentrations of indoor emitted pollutants while requiring some energy for fan(s) and thermal conditioning of the added airflow. This work demonstrates a physics based, data driven modeling framework for comparing the costs and benefits of whole-house mechanical ventilation and applied the framework to new California homes. The results indicate that, on a population basis, the health benefits from reduced exposure to indoor pollutants in New California homes are worth the energy costs of adding mechanical ventilation as specified by ASHRAE Standard 62.2.This study determines the health burden for a subset of pollutants in indoor air and the costs and benefits of ASHRAE's mechanical ventilation standard (62.2) for new California homes. Results indicate that, on a population basis, the health benefits of new home mechanical ventilation justify the energy costs.

  6. Healthy Zero Energy Buildings (HZEB) Program Interim Report on Cross Sectional Study of Contaminant Levels, Source Strengths, and Ventilation Rates in Retail Stores

    E-Print Network [OSTI]

    Chan, Wanyu R.

    2014-01-01T23:59:59.000Z

    Refrigerating, and Air Conditioning Engineers, Inc. Bennett,Ventilating, and Air Conditioning Survey of Small and MediumRefrigerating and Air- Conditioning Engineers (ASHRAE,

  7. air quality ventilation: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    dynamics in the South Coast Air Basin of California. It has also been modified to model pollution in South Korea, Mexico Manohar, Rajit 107 Predicting Air Quality: Current Status...

  8. The Histoty of Ventilation and Air Conditioning is CERN Up to Date with the latest Technological Developments?

    E-Print Network [OSTI]

    Kühnl-Kinel, J

    2000-01-01T23:59:59.000Z

    The invention of ventilation cannot be ascribed to a certain date. It started with simple aeration when man brought fire into his abode and continued through different stages including air cooling using ice to finally arrive at the time when ventilation and air conditioning has become an essential part of our life and plays an important role in human evolution. This paper presents the history of ventilation and air conditioning, explains the key constraints over the centuries, and shows its influence on everyday life. Some examples of previous air-conditioning plants are described and different approaches to the way of calculation of ventilation systems discussed. It gives an overview of the Heating, Ventilation and Air Conditioning (HVAC) installations at CERN and points out their particularities. It also compares them with the latest technological developments in the field as well as showing the new trends that are being applied at CERN.

  9. Reduceret energiforbrug til ventilation af bygninger

    E-Print Network [OSTI]

    Reduceret energiforbrug til ventilation af bygninger hvori der systematisk er valgt lav. 23. November 2007 #12;#12;Reduced energy use for ventilation of buildings through selection of low ventilation rate on perceived quality of air polluted by different materials, small ­ scale and full ­ scale

  10. Changing ventilation rates in U.S. offices: Implications for health, work performance, energy, and associated economics

    SciTech Connect (OSTI)

    Fisk, William; Black, Douglas; Brunner, Gregory

    2011-07-01T23:59:59.000Z

    This paper provides quantitative estimates of benefits and costs of providing different amounts of outdoor air ventilation in U.S. offices. For four scenarios that modify ventilation rates, we estimated changes in sick building syndrome (SBS) symptoms, work performance, short-term absence, and building energy consumption. The estimated annual economic benefits were $13 billion from increasing minimum ventilation rates (VRs) from 8 to 10 L/s per person, $38 billion from increasing minimum VRs from 8 to 15 L/s per person, and $33 billion from increasing VRs by adding outdoor air economizers for the 50% of the office floor area that currently lacks economizers. The estimated $0.04 billion in annual energy-related benefits of decreasing minimum VRs from 8 to 6.5 L/s per person are very small compared to the projected annual costs of $12 billion. Benefits of increasing minimum VRs far exceeded energy costs while adding economizers yielded health, performance, and absence benefits with energy savings.

  11. Ventilation during air breathing and in response to hypercapnia in 5 and 16 month-old mdx and C57 mice

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Ventilation during air breathing and in response to hypercapnia in 5 and 16 month-old mdx and C57-37 #12;Ventilation during air breathing and in response to hypercapnia in 5 and 16 month-old mdx and C57), and minute ventilation (VE) were measured, using whole-body plethysmography, during air breathing

  12. BUILDING VENTILATION AND INDOOR AIR QUALITY PROGRAM. CHAPTER FROM ENERGY AND ENVIRONMENT DIVISION ANNUAL REPORT 1978

    E-Print Network [OSTI]

    Cairns, Elton J.

    2011-01-01T23:59:59.000Z

    and in new "energy-efficient design" hospitals. Developmentenergy-efficient ventilation standards and ventilation designs

  13. Air Flow Distribution in a Mechanically-Ventilated High-Rise Residential Building* Richard C. Diamond and Helmut E. Feustel

    E-Print Network [OSTI]

    Diamond, Richard

    energy efficiency in public housing as part of a utility's Demand Side Management (DSM) Program of the supply ventilation register for each corridor. The building is exposed on all sides to the windAir Flow Distribution in a Mechanically-Ventilated High-Rise Residential Building* Richard C

  14. Developing evidence-based prescriptive ventilation rate standards for commercial buildings in California: a proposed framework

    SciTech Connect (OSTI)

    Mendell, Mark J.; Fisk, William J.

    2014-02-01T23:59:59.000Z

    Background - The goal of this project, with a focus on commercial buildings in California, was to develop a new framework for evidence-based minimum ventilation rate (MVR) standards that protect occupants in buildings while also considering energy use and cost. This was motivated by research findings suggesting that current prescriptive MVRs in commercial buildings do not provide occupants with fully safe and satisfactory indoor environments. Methods - The project began with a broad review in several areas ? the diverse strategies now used for standards or guidelines for MVRs or for environmental contaminant exposures, current knowledge about adverse human effects associated with VRs, and current knowledge about contaminants in commercial buildings, including their their presence, their adverse human effects, and their relationships with VRs. Based on a synthesis of the reviewed information, new principles and approaches are proposed for setting evidence-based VRs standards for commercial buildings, considering a range of human effects including health, performance, and acceptability of air. Results ? A review and evaluation is first presented of current approaches to setting prescriptive building ventilation standards and setting acceptable limits for human contaminant exposures in outdoor air and occupational settings. Recent research on approaches to setting acceptable levels of environmental exposures in evidence-based MVR standards is also described. From a synthesis and critique of these materials, a set of principles for setting MVRs is presented, along with an example approach based on these principles. The approach combines two sequential strategies. In a first step, an acceptable threshold is set for each adverse outcome that has a demonstrated relationship to VRs, as an increase from a (low) outcome level at a high reference ventilation rate (RVR, the VR needed to attain the best achievable levels of the adverse outcome); MVRs required to meet each specific outcome threshold are estimated; and the highest of these MVRs, which would then meet all outcome thresholds, is selected as the target MVR. In a second step, implemented only if the target MVR from step 1 is judged impractically high, costs and benefits are estimated and this information is used in a risk management process. Four human outcomes with substantial quantitative evidence of relationships to VRs are identified for initial consideration in setting MVR standards. These are: building-related symptoms (sometimes called sick building syndrome symptoms), poor perceived indoor air quality, and diminished work performance, all with data relating them directly to VRs; and cancer and non-cancer chronic outcomes, related indirectly to VRs through specific VR-influenced indoor contaminants. In an application of step 1 for offices using a set of example outcome thresholds, a target MVR of 9 L/s (19 cfm) per person was needed. Because this target MVR was close to MVRs in current standards, use of a cost/benefit process seemed unnecessary. Selection of more stringent thresholds for one or more human outcomes, however, could raise the target MVR to 14 L/s (30 cfm) per person or higher, triggering the step 2 risk management process. Consideration of outdoor air pollutant effects would add further complexity to the framework. For balancing the objective and subjective factors involved in setting MVRs in a cost-benefit process, it is suggested that a diverse group of stakeholders make the determination after assembling as much quantitative data as possible.

  15. BUILDING VENTILATION AND INDOOR AIR QUALITY PROGRAM. CHAPTER FROM ENERGY AND ENVIRONMENT DIVISION ANNUAL REPORT 1978

    E-Print Network [OSTI]

    Cairns, Elton J.

    2011-01-01T23:59:59.000Z

    The first section on the Ventilation Program, funded by thea large study on hospital ventilation require- ments.iii Ventilation Program C. D. Hollowell, A. Anaclerio, D. W.

  16. Commissioning Residential Ventilation Systems: A Combined Assessment of Energy and Air Quality Potential Values

    E-Print Network [OSTI]

    Turner, William J.N.

    2014-01-01T23:59:59.000Z

    through dynamic control of ventilation systems. Energy andcontinuous mechanical ventilation systems a mean annualcompliant ASHRAE 62.2 ventilation system. Table 12: Average

  17. Risk Factors in Heating, Ventilating, and Air-Conditioning Systems for Occupant Symptoms in

    E-Print Network [OSTI]

    Mendell, M.J.; Lei-Gomez, Q.; Mirer, A.; Seppanen, O.; Brunner, G.

    2007-01-01T23:59:59.000Z

    for building ventilation systems." Retrieved December 15,of moisture and ventilation system contamination in U.S.installed in office ventilation systems on workers' health

  18. Air change effectiveness in laboratory tests of combined chilled ceiling and displacement ventilation.

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred; Tully, Brad; Rimmer, Julian

    2011-01-01T23:59:59.000Z

    and displacement ventilation systems. Energy and Buildings,and displacement ventilation systems. Submitted to HVAC&R (and displacement ventilation system. According to Novoselac

  19. Energy and air quality implications of passive stack ventilation in residential buildings

    E-Print Network [OSTI]

    Mortensen, Dorthe Kragsig

    2011-01-01T23:59:59.000Z

    tighter, designed ventilation systems are more frequentlyof passive stack ventilation systems. They have been usedto having a good ventilation system and therefore also to

  20. Room air stratification in combined chilled ceiling and displacement ventilation systems.

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred; Tully, Brad; Rimmer, Julian

    2012-01-01T23:59:59.000Z

    and displacement ventilation systems. HVAC&R Research, 12 (and displacement ventilation system. ASHRAE RP-1438 Finalof Displacement Ventilation System—Experimental and

  1. BUILDING VENTILATION AND INDOOR AIR QUALITY PROGRAM. CHAPTER FROM ENERGY AND ENVIRONMENT DIVISION ANNUAL REPORT 1978

    E-Print Network [OSTI]

    Cairns, Elton J.

    2011-01-01T23:59:59.000Z

    of automatic variable ventilation control systems based onof automatic variable ventilation control systems, The Johnbe developed. Automatic Variable Ventilation Control Systems

  2. HOSPITAL VENTILATION STANDARDS AND ENERGY CONSERVATION: CHEMICAL CONTAMINATION OF HOSPITAL AIR. FINAL REPORT.

    E-Print Network [OSTI]

    Rainer, David

    2012-01-01T23:59:59.000Z

    open bench top local exhaust ventilation, The OSHA standardsuch as local ex- haust ventilation when properly applied,

  3. Measuring Outdoor Air Intake Rates into Existing Building

    SciTech Connect (OSTI)

    Fisk, William; Sullivan, Douglas; Cohen, Sebastian; Han, Hwataik

    2009-04-16T23:59:59.000Z

    Practical and accurate technologies are needed for continuously measuring and controlling outdoor air (OA) intake rates in commercial building heating, ventilating, and air conditioning (HVAC) systems. This project evaluated two new measurement approaches. Laboratory experiments determined that OA flow rates were measurable with errors generally less than 10 percent using electronic air velocity probes installed between OA intake louver blades or at the outlet face of louvers. High accuracy was maintained with OA flow rates as low as 15 percent of the maximum for the louvers. Thus, with this measurement approach HVAC systems do not need separate OA intakes for minimum OA supply. System calibration parameters are required for each unique combination of louver type and velocity sensor location but calibrations are not necessary for each system installation. The research also determined that the accuracy of measuring OA flow rates with velocity probes located in the duct downstream of the intake louver was not improved by installing honeycomb airflow straighteners upstream of the probes. Errors varied with type of upstream louver, were as high as 100 percent, and were often greater than 25 percent. In conclusion, use of electronic air velocity probes between the blades of OA intake louvers or at the outlet face of louvers is a highly promising means of accurately measuring rates of OA flow into HVAC systems. The use of electronic velocity probes downstream of airflow straighteners is less promising, at least with the relatively small OA HVAC inlet systems employed in this research.

  4. DEMAND CONTROLLED VENTILATION AND CLASSROOM VENTILATION

    SciTech Connect (OSTI)

    Fisk, William J.; Mendell, Mark J.; Davies, Molly; Eliseeva, Ekaterina; Faulkner, David; Hong, Tienzen; Sullivan, Douglas P.

    2014-01-06T23:59:59.000Z

    This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling. Major findings included: ? The single-location carbon dioxide sensors widely used for demand controlled ventilation frequently have large errors and will fail to effectively control ventilation rates (VRs).? Multi-location carbon dioxide measurement systems with more expensive sensors connected to multi-location sampling systems may measure carbon dioxide more accurately.? Currently-available optical people counting systems work well much of the time but have large counting errors in some situations. ? In meeting rooms, measurements of carbon dioxide at return-air grilles appear to be a better choice than wall-mounted sensors.? In California, demand controlled ventilation in general office spaces is projected to save significant energy and be cost effective only if typical VRs without demand controlled ventilation are very high relative to VRs in codes. Based on the research, several recommendations were developed for demand controlled ventilation specifications in the California Title 24 Building Energy Efficiency Standards.The research on classroom ventilation collected data over two years on California elementary school classrooms to investigate associations between VRs and student illness absence (IA). Major findings included: ? Median classroom VRs in all studied climate zones were below the California guideline, and 40percent lower in portable than permanent buildings.? Overall, one additional L/s per person of VR was associated with 1.6percent less IA. ? Increasing average VRs in California K-12 classrooms from the current average to the required level is estimated to decrease IA by 3.4percent, increasing State attendance-based funding to school districts by $33M, with $6.2 M in increased energy costs. Further VR increases would provide additional benefits.? Confirming these findings in intervention studies is recommended. ? Energy costs of heating/cooling unoccupied classrooms statewide are modest, but a large portion occurs in relatively few classrooms.

  5. Heating, Ventilating, and Air-Conditioning: Recent Advances in Diagnostics and Controls to Improve Air-Handling System Performance

    E-Print Network [OSTI]

    Wray, Craig P.

    2008-01-01T23:59:59.000Z

    step in designing a ventilation system is determining theto shut down the ventilation system for a period of timeperiod with the ventilation system off (e.g. , at least 6

  6. Proposal for the award of a contract for the design, supply, installation and commissioning of an HVAC (Heating, Ventilation and Air Conditioning) system for Building 3862

    E-Print Network [OSTI]

    2014-01-01T23:59:59.000Z

    Proposal for the award of a contract for the design, supply, installation and commissioning of an HVAC (Heating, Ventilation and Air Conditioning) system for Building 3862

  7. Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel

    E-Print Network [OSTI]

    2012-01-01T23:59:59.000Z

    Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel

  8. Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure

    E-Print Network [OSTI]

    2012-01-01T23:59:59.000Z

    Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure

  9. Proposal for the award of two service contracts for the operation, maintenance and other work relating to the heating, ventilation, air-conditioning and plumbing facilities at CERN

    E-Print Network [OSTI]

    2011-01-01T23:59:59.000Z

    Proposal for the award of two service contracts for the operation, maintenance and other work relating to the heating, ventilation, air-conditioning and plumbing facilities at CERN

  10. A survey and critical review of the literature on indoor air quality, ventilation and health symptoms in schools

    SciTech Connect (OSTI)

    Daisey, J.M. [Lawrence Berkeley National Lab., CA (United States). Energy and Environment Div.; Angell, W.J. [Univ. of Minnesota, St. Paul, MN (United States)

    1998-03-01T23:59:59.000Z

    A survey and critical review were undertaken of existing published literature and reports on indoor air quality (IAQ), ventilation, and IAQ- and building-related health problems in schools, including California schools. Over 450 relevant publications were obtained and reviewed, including papers published in the archival peer-reviewed scientific literature, proceedings of scientific meetings, government reports, 77 NIOSH Health Hazard Evaluation Reports (HHER) and 70 reports on investigations of problem schools in California. Most of the reviewed literature was for complaint or problem schools. The types of health symptoms reported in schools were very similar to those defined as sick building syndrome (SBS) symptoms, although this may be due, at least in part, to the type of health symptom questionnaires used. Some of the symptoms, e.g., wheezing, are indicative of asthma. In the studies in which complaint and noncomplaint buildings or areas were compared, complaint buildings generally had higher rates of health symptoms.

  11. Commissioning of a Coupled Earth Tube and Natural Ventilation System at the Design Phase

    E-Print Network [OSTI]

    Yoshida, H.; Pan, S.; Zheng, M.

    2007-01-01T23:59:59.000Z

    Natural ventilation airflow rate is generally calculated using indoor and outdoor temperature difference without consideration of thermal interaction between the ventilated air and the room in simple analytical method based on pressure balance...

  12. Cooling airflow design tool for displacement ventilation.

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred

    2009-01-01T23:59:59.000Z

    Tool for Displacement Ventilation: User Notes 2|Page 5.air  temperature.   Ventilation effectiveness is equivalent for Displacement  Ventilation (Chen and Glicksman 2003).  

  13. Ventilating Existing Homes in the US Air Infiltration Review. 2010;31(2)

    E-Print Network [OSTI]

    mechanical ventilation fan leads to reductions in other measures, such as adding insulation. This has led

  14. Energy saving strategies with personalized ventilation in tropics

    E-Print Network [OSTI]

    Schiavon, Stefano; Melikov, Arsen; Chandra Sekhar, Chandra Sekhar

    2010-01-01T23:59:59.000Z

    integrated personalized ventilation for minimizing crossMelikov, Personalized ventilation, Indoor Air, vol. 14 (to personalized and mixing ventilation, Indoor Air 14 (

  15. Inverse Design Methods for Indoor Ventilation Systems Using1 CFD-Based Multi-Objective Genetic Algorithm2

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    use efficiency are three important29 indices for heating, ventilation and air-conditioning (HVAC1 Inverse Design Methods for Indoor Ventilation Systems Using1 CFD-Based Multi equilibrium and require ventilation rates of12 a space to design ventilation systems for the space

  16. Rating of Mixed Split Residential Air Conditioners

    E-Print Network [OSTI]

    Domanski, P. A.

    1988-01-01T23:59:59.000Z

    A methodology is presented for rating the performance of mixed, split residential air conditioners. The method accounts for the impact on system performance of the indoor evaporator, expansion device and fan; three major components that are likely...

  17. Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

    E-Print Network [OSTI]

    Sherman, Max H.

    2011-01-01T23:59:59.000Z

    with a detailed heating, ventilation, and air conditioning (well as ventilation systems integrated into heating (naturalventilation standards, including American Society of Heating,

  18. Impacts of Mixing on Acceptable Indoor Air Quality in Homes

    E-Print Network [OSTI]

    have central heating, ventilation, and air conditioning systems, which tend to mix the air; thus of Mixing on Acceptable Indoor Air Quality in Homes ABSTRACT Ventilation reduces occupant exposure to indoor different dilution rates and contaminant source strengths. The total ventilation rate is the most important

  19. Meeting Residential Ventilation Standards

    E-Print Network [OSTI]

    ventilation standards, including American Society of Heating, Refrigerating, and Air-conditioning EngineersLBNL 4591E Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems (ASHRAE) Standard 62.2, specify continuous operation of a defined mechanical ventilation system to provide

  20. Ventilation efficiencies of a desk-edge-mounted task ventilation system

    E-Print Network [OSTI]

    Faulkner, David; Fisk, William J.; Sullivan, Douglas P.; Lee, Seung Min

    2002-01-01T23:59:59.000Z

    DESK-EDGE-MOUNTED TASK VENTILATION SYSTEM D Faulkner * , WJthe effectiveness of a task ventilation system with an airthe desk. The task ventilation system provided outside air,

  1. The Impact of CO2-Based Demand-Controlled Ventilation on Energy Consumptions for Air Source Heat Pumps in Schools

    E-Print Network [OSTI]

    AlRaees, N.; Nassif, N.

    2013-01-01T23:59:59.000Z

    There have been increasingly growing concerns for many years over the quality of the air inside buildings and the associated energy use. The CO2-based demand-controlled ventilation DCV offers a great opportunity to reduce energy consumption in HVAC...

  2. ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality...

    Broader source: Energy.gov (indexed) [DOE]

    ensured dilution is dependent on an effective base standard for whole-house and spot ventilation. This is why the ASHRAE 62.2 residential ventilation standard is critical to...

  3. Airflow Simulation and Energy Analysis in Ventilated Room with a New Type of Air Conditioning

    E-Print Network [OSTI]

    Liu, D.; Tang, G.; Zhao, F.

    2006-01-01T23:59:59.000Z

    Airflow simulation in one ventilated room with radiant heating and natural ventilation has been carried out. Three cases are compared: the closed room, the room with full openings, and the room with small openings. The radiator heating room...

  4. Methodology for the evaluation of natural ventilation in buildings using a reduced-scale air model

    E-Print Network [OSTI]

    Walker, Christine E. (Christine Elaine)

    2006-01-01T23:59:59.000Z

    Commercial office buildings predominantly are designed to be ventilated and cooled using mechanical systems. In temperate climates, passive ventilation and cooling techniques can be utilized to reduce energy consumption ...

  5. Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems

    E-Print Network [OSTI]

    Wetter, Michael

    2010-01-01T23:59:59.000Z

    to a strati?ed thermal energy storage Figure 5: Model ofsystem with thermal energy storage. (to model ventilation

  6. CASANZ Conference Linking Air Pollution, Science, Policy and Management -Newcastle, NSW Australia 23-27 Nov 2003 Page 1 of 5

    E-Print Network [OSTI]

    Kentucky, University of

    CASANZ Conference ­ Linking Air Pollution, Science, Policy and Management - Newcastle, NSW related to ventilation rate changes. Keywords: Chicken, Ventilation, Air Quality, Poultry. 1. Introduction about the industry's impact on local and regional air quality. Quantitative estimates are also required

  7. Formaldehyde as a Basis for Residential Ventilation Rates1 M.H. Sherman (MHSherman@lbl.gov) and A.T. Hodgson (ATHodgson@lbl.gov)

    E-Print Network [OSTI]

    LBNL-49577 Formaldehyde as a Basis for Residential Ventilation Rates1 M.H. Sherman (MHSherman, houses in the U.S. have been ventilated by passive infiltration in combination with active window opening to reduce infiltration, and the use of windows for ventilation also may have decreased due to a number

  8. Worker productivity and ventilation rate in a call center: Analyses of time-series data for a group of registered nurses

    SciTech Connect (OSTI)

    Fisk, William J.; Price, Phillip; Faulkner, David; Sullivan, Douglas; Dibartolomeo, Dennis

    2003-08-01T23:59:59.000Z

    We investigated the relationship of ventilation rates with the performance of advice nurses working in a call center. Ventilation rates were manipulated; temperatures, humidities, and CO{sub 2} concentrations were monitored; and worker performance data, with 30-minute resolution, were collected. Multivariate linear regression was used to investigate the association of worker performance with indoor minus outdoor CO{sub 2} concentration (which increases with decreasing ventilation rate per worker) and with building ventilation rate. Results suggest that the effect of ventilation rate on worker performance in this call center was very small (probably less than 1%) or nil, over most of the range of ventilation rate (roughly 12 L s{sup -1} to 48 L s{sup -1} per person). However, there is some evidence of worker performance improvements of 2% or more when the indoor CO{sub 2} concentration exceeded the outdoor concentration by less than 75 ppm.

  9. Infiltration in ASHRAE's Residential Ventilation Standards

    E-Print Network [OSTI]

    Sherman, Max

    2008-01-01T23:59:59.000Z

    of  the effective natural ventilation rate with weather to  Residential  Ventilation  Requirements”.  LBNL  57236.  and  M.H.   Sherman  "Ventilation  Behavior  and  Household 

  10. An Index for Evaluation of Air Quality Improvement in Rooms with Personalized Ventilation Based on Occupied Density and Normalized Concentration

    E-Print Network [OSTI]

    Schiavon, Stefano; Melikov, Arsen; Cermak, Radim; De Carli, Michele; Li, Xianting

    2007-01-01T23:59:59.000Z

    potential of personalized ventilation system in the tropics.edge mounted task ventilation system. Proceedings of Indoorwith a total-volume ventilation system. The index is applied

  11. A Survey and Critical Review of the Literature on Indoor Air Quality, Ventilation and Health Symptoms in Schools

    E-Print Network [OSTI]

    Daisey, Joan M.

    2010-01-01T23:59:59.000Z

    between seasons and ventilation systems, Proceedings ofto Old school: ventilation system, one constructed prior toall had mechanical ventilation systems of some type. C 0

  12. BUILDING VENTILATION AND INDOOR AIR QUALITY PROGRAM. CHAPTER FROM ENERGY AND ENVIRONMENT DIVISION ANNUAL REPORT 1978

    E-Print Network [OSTI]

    Cairns, Elton J.

    2011-01-01T23:59:59.000Z

    heat exchangers; additional subcontract activities consisting of: • field survey of current practices in enforcement of ventilation regulations; COMMERCIAL ENERGY CONSUMPTION DATA (

  13. Lee, K.S., Zhang, T., Jiang, Z., and Chen, Q. 2009. "Comparison of airflow and contaminant distributions in rooms with traditional displacement ventilation and under-floor air distribution systems,"

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    systems had higher ventilation performance than the mixing one under cooling mode as well as under heating distributions in rooms with traditional displacement ventilation and under-floor air distribution systems with traditional displacement ventilation and under-floor air distribution systems Kisup Lee* Tengfei Zhang, Ph

  14. Sensor-based demand controlled ventilation

    SciTech Connect (OSTI)

    De Almeida, A.T. [Universidade de Coimbra (Portugal). Dep. Eng. Electrotecnica; Fisk, W.J. [Lawrence Berkeley National Lab., CA (United States)

    1997-07-01T23:59:59.000Z

    In most buildings, occupancy and indoor pollutant emission rates vary with time. With sensor-based demand-controlled ventilation (SBDCV), the rate of ventilation (i.e., rate of outside air supply) also varies with time to compensate for the changes in pollutant generation. In other words, SBDCV involves the application of sensing, feedback and control to modulate ventilation. Compared to ventilation without feedback, SBDCV offers two potential advantages: (1) better control of indoor pollutant concentrations; and (2) lower energy use and peak energy demand. SBDCV has the potential to improve indoor air quality by increasing the rate of ventilation when indoor pollutant generation rates are high and occupants are present. SBDCV can also save energy by decreasing the rate of ventilation when indoor pollutant generation rates are low or occupants are absent. After providing background information on indoor air quality and ventilation, this report provides a relatively comprehensive discussion of SBDCV. Topics covered in the report include basic principles of SBDCV, sensor technologies, technologies for controlling air flow rates, case studies of SBDCV, application of SBDCV to laboratory buildings, and research needs. SBDCV appears to be an increasingly attractive technology option. Based on the review of literature and theoretical considerations, the application of SBDCV has the potential to be cost-effective in applications with the following characteristics: (a) a single or small number of dominant pollutants, so that ventilation sufficient to control the concentration of the dominant pollutants provides effective control of all other pollutants; (b) large buildings or rooms with unpredictable temporally variable occupancy or pollutant emission; and (c) climates with high heating or cooling loads or locations with expensive energy.

  15. Energy Code Enforcement Training Manual : Covering the Washington State Energy Code and the Ventilation and Indoor Air Quality Code.

    SciTech Connect (OSTI)

    Washington State Energy Code Program

    1992-05-01T23:59:59.000Z

    This manual is designed to provide building department personnel with specific inspection and plan review skills and information on provisions of the 1991 edition of the Washington State Energy Code (WSEC). It also provides information on provisions of the new stand-alone Ventilation and Indoor Air Quality (VIAQ) Code.The intent of the WSEC is to reduce the amount of energy used by requiring energy-efficient construction. Such conservation reduces energy requirements, and, as a result, reduces the use of finite resources, such as gas or oil. Lowering energy demand helps everyone by keeping electricity costs down. (It is less expensive to use existing electrical capacity efficiently than it is to develop new and additional capacity needed to heat or cool inefficient buildings.) The new VIAQ Code (effective July, 1991) is a natural companion to the energy code. Whether energy-efficient or not, an homes have potential indoor air quality problems. Studies have shown that indoor air is often more polluted than outdoor air. The VIAQ Code provides a means of exchanging stale air for fresh, without compromising energy savings, by setting standards for a controlled ventilation system. It also offers requirements meant to prevent indoor air pollution from building products or radon.

  16. Adventitious ventilation: a new definition for an old mode?

    E-Print Network [OSTI]

    Schiavon, Stefano

    2014-01-01T23:59:59.000Z

    Refrigeration and Air-Conditioning Engineers (ASHRAEof ventilation and air- conditioning system types in officeto natural ventilation, air conditioning, with or without

  17. Energy-saving strategies with personalized ventilation in cold climates

    E-Print Network [OSTI]

    Schiavon, Stefano; Melikov, Arsen

    2009-01-01T23:59:59.000Z

    Journal of heating, Ventilation and Refrigeration Research,on Cold Climate, Heating, Ventilation and Air-Conditioning,Ventilation Effectiveness, Federation of European Heating

  18. Energy saving strategies with personalized ventilation in tropics

    E-Print Network [OSTI]

    Schiavon, Stefano; Melikov, Arsen; Chandra Sekhar, Chandra Sekhar

    2010-01-01T23:59:59.000Z

    of a personalized ventilation system in the tropics, in:edged-mounted task ventilation system, Indoor Air, Vol. 14 (a chair-based personalized ventilation system, Building and

  19. Energy-saving strategies with personalized ventilation in cold climates

    E-Print Network [OSTI]

    Schiavon, Stefano; Melikov, Arsen

    2009-01-01T23:59:59.000Z

    potential of personalized ventilation system in the tropics,edged-mounted task ventilation system, Indoor Air, Vol. 14 (a chair-based personalized ventilation system, Building and

  20. air change rate: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Rydhof 2 Traffic-related air pollution exposures and changes in heart rate variability in Mexico City: A panel study MIT - DSpace Summary: Abstract Background While air pollution...

  1. air change rates: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Rydhof 2 Traffic-related air pollution exposures and changes in heart rate variability in Mexico City: A panel study MIT - DSpace Summary: Abstract Background While air pollution...

  2. Energy and air quality implications of passive stack ventilation in residential buildings

    E-Print Network [OSTI]

    Mortensen, Dorthe Kragsig

    2011-01-01T23:59:59.000Z

    scaling the passive stack diameter with house size (floora single-story house ventilated by a passive stack with andTable 1: Passive stack diameters scaling with house size

  3. Ventilation Model

    SciTech Connect (OSTI)

    V. Chipman

    2002-10-05T23:59:59.000Z

    The purpose of the Ventilation Model is to simulate the heat transfer processes in and around waste emplacement drifts during periods of forced ventilation. The model evaluates the effects of emplacement drift ventilation on the thermal conditions in the emplacement drifts and surrounding rock mass, and calculates the heat removal by ventilation as a measure of the viability of ventilation to delay the onset of peak repository temperature and reduce its magnitude. The heat removal by ventilation is temporally and spatially dependent, and is expressed as the fraction of heat carried away by the ventilation air compared to the fraction of heat produced by radionuclide decay. One minus the heat removal is called the wall heat fraction, or the remaining amount of heat that is transferred via conduction to the surrounding rock mass. Downstream models, such as the ''Multiscale Thermohydrologic Model'' (BSC 2001), use the wall heat fractions as outputted from the Ventilation Model to initialize their post-closure analyses. The Ventilation Model report was initially developed to analyze the effects of preclosure continuous ventilation in the Engineered Barrier System (EBS) emplacement drifts, and to provide heat removal data to support EBS design. Revision 00 of the Ventilation Model included documentation of the modeling results from the ANSYS-based heat transfer model. The purposes of Revision 01 of the Ventilation Model are: (1) To validate the conceptual model for preclosure ventilation of emplacement drifts and verify its numerical application in accordance with new procedural requirements as outlined in AP-SIII-10Q, Models (Section 7.0). (2) To satisfy technical issues posed in KTI agreement RDTME 3.14 (Reamer and Williams 2001a). Specifically to demonstrate, with respect to the ANSYS ventilation model, the adequacy of the discretization (Section 6.2.3.1), and the downstream applicability of the model results (i.e. wall heat fractions) to initialize post-closure thermal models (Section 6.6). (3) To satisfy the remainder of KTI agreement TEF 2.07 (Reamer and Williams 2001b). Specifically to provide the results of post-test ANSYS modeling of the Atlas Facility forced convection tests (Section 7.1.2). This portion of the model report also serves as a validation exercise per AP-SIII.10Q, Models, for the ANSYS ventilation model. (4) To further satisfy KTI agreements RDTME 3.01 and 3.14 (Reamer and Williams 2001a) by providing the source documentation referred to in the KTI Letter Report, ''Effect of Forced Ventilation on Thermal-Hydrologic Conditions in the Engineered Barrier System and Near Field Environment'' (Williams 2002). Specifically to provide the results of the MULTIFLUX model which simulates the coupled processes of heat and mass transfer in and around waste emplacement drifts during periods of forced ventilation. This portion of the model report is presented as an Alternative Conceptual Model with a numerical application, and also provides corroborative results used for model validation purposes (Section 6.3 and 6.4).

  4. Commissioning Residential Ventilation Systems: A Combined Assessment of Energy and Air Quality Potential Values

    E-Print Network [OSTI]

    Turner, William J.N.

    2014-01-01T23:59:59.000Z

    Washinton D.C. , Air Conditioning Contractors of America.Refrigeration and Air Conditioning Engineers. ASHRAE 2009a.Refrigerating, and Air-Conditioning Engineers. ASHRAE 2009b.

  5. Impact of a task-ambient ventilation system on perceived air quality

    E-Print Network [OSTI]

    2008-01-01T23:59:59.000Z

    Comfort, perceived air quality, and work performance in aperception of indoor air quality during immediate and longerassessments of indoor air-quality in five European

  6. 16 P R O G R E S S R E S E a R c h & D i S c O v E R y Nu-Air Ventilation Systems began nearly three

    E-Print Network [OSTI]

    Brownstone, Rob

    three decades ago designing and manufacturing heat recovery ventilation (HRV) systems--vital pieceLeft)JulioMilitzerandBrianGibbon SandorFizli sector: Heating and ventilation Mission: Nu-Air is an important supplier of air exchanger16 P R O G R E S S R E S E a R c h & D i S c O v E R y Nu-Air Ventilation Systems began nearly

  7. Optimization of Occupancy Based Demand Controlled Ventilation in Residences

    SciTech Connect (OSTI)

    Mortensen, Dorthe K.; Walker, Iain S.; Sherman, Max H.

    2011-05-01T23:59:59.000Z

    Although it has been used for many years in commercial buildings, the application of demand controlled ventilation in residences is limited. In this study we used occupant exposure to pollutants integrated over time (referred to as 'dose') as the metric to evaluate the effectiveness and air quality implications of demand controlled ventilation in residences. We looked at air quality for two situations. The first is that typically used in ventilation standards: the exposure over a long term. The second is to look at peak exposures that are associated with time variations in ventilation rates and pollutant generation. The pollutant generation had two components: a background rate associated with the building materials and furnishings and a second component related to occupants. The demand controlled ventilation system operated at a low airflow rate when the residence was unoccupied and at a high airflow rate when occupied. We used analytical solutions to the continuity equation to determine the ventilation effectiveness and the long-term chronic dose and peak acute exposure for a representative range of occupancy periods, pollutant generation rates and airflow rates. The results of the study showed that we can optimize the demand controlled airflow rates to reduce the quantity of air used for ventilation without introducing problematic acute conditions.

  8. Duct Systems in large commercial buildings: Physical characterization, air leakage, and heat conduction gains

    E-Print Network [OSTI]

    Fisk, W.J.

    2011-01-01T23:59:59.000Z

    fabricators of heating, ventilation, and air conditioningof Building Heating, Ventilation, Air Conditioning, and

  9. LBNL-XXXXX | Logue et al., Evaluation of an Incremental Ventilation Energy Model for Estimating Impacts of Air Sealing and Mechanical Ventilation

    E-Print Network [OSTI]

    LBNL-XXXXX | Logue et al., Evaluation of an Incremental Ventilation Energy Model for Estimating. Turner, Iain S. Walker, and Brett C. Singer Environmental Energy Technologies Division June 2012 LBNL-5796E #12;LBNL-XXXXX | Logue et al., Evaluation of an Incremental Ventilation Energy Model

  10. RESIDENTIAL VENTILATION AND ENERGY CHARACTERISTICS*

    E-Print Network [OSTI]

    RESIDENTIAL VENTILATION AND ENERGY CHARACTERISTICS* Max Sherman Nance Matson Energy Performance Berkeley, California The role of ventilation in the housing stock is to provide fresh air and to dilute to provide this ventilation service, either directly for moving the air or indirectly for conditioning

  11. Developing evidence-based prescriptive ventilation rate standards for commercial buildings in California: a proposed framework

    E-Print Network [OSTI]

    Mendell, Mark J.

    2014-01-01T23:59:59.000Z

    Refrigerating, and Air Conditioning Engineers, Inc. ASHRAE.Refrigerating and Air- Conditioning Engineers, Inc. ASHRAE.Refrigerating and Air-Conditioning Engineers, Inc. Beko Gl,

  12. Energy Efficient Process Heating: Managing Air Flow Kevin Carpenter and Kelly Kissock

    E-Print Network [OSTI]

    Kissock, Kelly

    temperature and decreased combustion gas mass flow rate. The method for calculating savings from preheating flow include minimizing combustion air, preheating combustion air, minimizing ventilation air from minimizing combustion air accounts for improvement in efficiency from increased combustion

  13. Advanced Controls for Residential Whole-House Ventilation Systems

    SciTech Connect (OSTI)

    Turner, William; Walker, Iain; Sherman, Max

    2014-08-01T23:59:59.000Z

    Whole-house ventilation systems are becoming commonplace in new construction, remodeling/renovation, and weatherization projects, driven by combinations of specific requirements for indoor air quality (IAQ), health and compliance with standards, such as ASHRAE 62.2. Ventilation systems incur an energy penalty on the home via fan power used to drive the airflow, and the additional space-conditioning load associated with heating or cooling the ventilation air. Finding a balance between IAQ and energy use is important if homes are to be adequately ventilated while not increasing the energy burden. This study used computer simulations to examine RIVEC the Residential Integrated Ventilation Controller - a prototype ventilation controller that aims to deliver whole-house ventilation rates that comply with ventilation standards, for the minimum use of energy. Four different whole-house ventilation systems were simulated, both with and without RIVEC, so that the energy and IAQ results could be compared. Simulations were conducted for 13 US climate zones, three house designs, and three envelope leakage values. The results showed that the RIVEC controller could typically return ventilation energy savings greater than 40percent without compromising long-term chronic or short-term acute exposures to relevant indoor contaminants. Critical and average peak power loads were also reduced as a consequence of using RIVEC.

  14. Ventilation Systems Operating Experience Review for Fusion Applications

    SciTech Connect (OSTI)

    Cadwallader, Lee Charles

    1999-12-01T23:59:59.000Z

    This report is a collection and review of system operation and failure experiences for air ventilation systems in nuclear facilities. These experiences are applicable for magnetic and inertial fusion facilities since air ventilation systems are support systems that can be considered generic to nuclear facilities. The report contains descriptions of ventilation system components, operating experiences with these systems, component failure rates, and component repair times. Since ventilation systems have a role in mitigating accident releases in nuclear facilities, these data are useful in safety analysis and risk assessment of public safety. An effort has also been given to identifying any safety issues with personnel operating or maintaining ventilation systems. Finally, the recommended failure data were compared to an independent data set to determine the accuracy of individual values. This comparison is useful for the International Energy Agency task on fusion component failure rate data collection.

  15. HOSPITAL VENTILATION STANDARDS AND ENERGY CONSERVATION: A SUMMARY OF THE LITERATURE WITH CONCLUSIONS AND RECOMMENDATIONS, FY 78 FINAL REPORT

    E-Print Network [OSTI]

    DeRoos, R.L.

    2011-01-01T23:59:59.000Z

    to prelude higher ventilation heating or cooling. InRequirements: --The ventilation, heating, air conditioning,and comfort. --The ventilation, heating, air conditioning,

  16. Temperature stratification and air change effectiveness in a high cooling load office with two heat source heights in a combined chilled ceiling and displacement ventilation system

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred; Tully, Brad; Rimmer, Julian

    2012-01-01T23:59:59.000Z

    ceiling and displacement ventilation system. Submitted toceiling and displacement ventilation system. Submitted toceiling and displacement ventilation systems, Energy Build.

  17. Physical features of small disperse coal dust fraction transportation and structurization processes in iodine air filters of absorption type in ventilation systems at nuclear power plants

    E-Print Network [OSTI]

    Ledenyov, Oleg P; Poltinin, P Ya; Fedorova, L I

    2012-01-01T23:59:59.000Z

    The research on the physical features of transportation and structurization processes by the air-dust aerosol in the granular filtering medium with the cylindrical coal adsorbent granules in an air filter of the adsorption type in the heating ventilation and cooling (HVAC) system at the nuclear power plant is completed. The physical origins of the coal dust masses distribution along the absorber with the granular filtering medium with the cylindrical coal granules during the air-dust aerosol intake process in the near the surface layer of absorber are researched. The quantitative technical characteristics of air filtering elements, which have to be considered during the optimization of air filters designs for the application in the ventilation systems at the nuclear power plants, are obtained.

  18. Saving Energy and Improving IAQ through Application of Advanced Air Cleaning Technologies

    E-Print Network [OSTI]

    Saving Energy and Improving IAQ through Application of Advanced Air Cleaning Technologies Table 1 equipment and people from particles. Criteria for Air Cleaning Reducing ventilation rates to save energy, we may be able use air cleaning systems and reduce rates of ventilation (i.e., reduce rates

  19. DOE ZERH Webinar: Ventilation and Filtration Strategies with Indoor airPLUS

    Broader source: Energy.gov [DOE]

    The Indoor airPLUS qualification, a prerequisite for Zero Energy Ready Homes, offers an important platform to improve the indoor air quality (IAQ) in high-performance homes.  A critical aspect of...

  20. Ventilation efficiencies and thermal comfort results of a desk-edge-mounted task ventilation system

    E-Print Network [OSTI]

    Faulkner, D.; Fisk, W.J.; Sullivan, D.P.; Lee, S.M.

    2003-01-01T23:59:59.000Z

    EDGE-MOUNTED TASK VENTILATION SYSTEM D Faulkner, WJ Fisk, DPDESK-EDGE-MOUNTED TASK VENTILATION SYSTEM D Faulkner * , WJcomfort of a task ventilation system with an air supply

  1. Energy efficient indoor VOC air cleaning with activated carbon fiber (ACF) filters Meera A. Sidheswaran a

    E-Print Network [OSTI]

    to reduce the energy required for heating and cooling of ventilation air by 35% to almost 50%. Ó 2011 Keywords: Activated carbon fiberVolatile organic compoundIndoor pollutantEnergy efficient ventilation a b allow reduced rates and energy consumption for outdoor air ventilation. We evaluated the use of ACF

  2. Advanced control strategies for heating, ventilation, air-conditioning, and refrigeration systems—An overview: Part I: Hard control

    SciTech Connect (OSTI)

    D. Subbaram Naidu; Craig G. Rieger

    2011-02-01T23:59:59.000Z

    A chronological overview of the advanced control strategies for heating, ventilation, air-conditioning, and refrigeration (HVAC&R) is presented in this article. The overview focuses on hard-computing or control techniques, such as proportional-integral-derivative, optimal, nonlinear, adaptive, and robust; soft-computing or control techniques, such as neural networks, fuzzy logic, genetic algorithms; and on the fusion or hybrid of hard- and soft-control techniques. Thus, it is to be noted that the terminology “hard” and “soft” computing/control has nothing to do with the “hardware” and “software” that is being generally used. Part I of a two-part series focuses on hard-control strategies, and Part II focuses on softand fusion-control in addition to some future directions in HVAC&R research. This overview is not intended to be an exhaustive survey on this topic, and any omission of other works is purely unintentional.

  3. Multifamily Ventilation Retrofit Strategies

    SciTech Connect (OSTI)

    Ueno, K.; Lstiburek, J.; Bergey, D.

    2012-12-01T23:59:59.000Z

    In multifamily buildings, central ventilation systems often have poor performance, overventilating some portions of the building (causing excess energy use), while simultaneously underventilating other portions (causing diminished indoor air quality). BSC and Innova Services Corporation performed a series of field tests at a mid-rise test building undergoing a major energy audit and retrofit, which included ventilation system upgrades.

  4. Infiltration Effects on Residential Pollutant Concentrations for Continuous and Intermittent Mechanical Ventilation Approaches

    E-Print Network [OSTI]

    Sherman, Max

    2010-01-01T23:59:59.000Z

    P. (2002). Technical Note AIVC 57: Residential Ventilation.Air Infiltration and Ventilation Center (AIVC) Edwards, R.Related to Residential Ventilation Requirements. Berkeley,

  5. Optimization of the Fin Heat Pipe for Ventilating and Air Conditioning with a Genetic Algorithm

    E-Print Network [OSTI]

    Qian, J.; Sun, D.; Li, G.

    2006-01-01T23:59:59.000Z

    This paper illustrates that use of a heat pipe as a heat-reclaiming device can significantly influence the air-conditioning system. It analyzes the heat transfer model of the uniform annular fin heat pipe under the condition of air conditioning...

  6. Optimization of the Fin Heat Pipe for Ventilating and Air Conditioning with a Genetic Algorithm 

    E-Print Network [OSTI]

    Qian, J.; Sun, D.; Li, G.

    2006-01-01T23:59:59.000Z

    This paper illustrates that use of a heat pipe as a heat-reclaiming device can significantly influence the air-conditioning system. It analyzes the heat transfer model of the uniform annular fin heat pipe under the condition of air conditioning...

  7. Does Mixing Make Residential Ventilation More Effective?

    SciTech Connect (OSTI)

    Sherman, Max; Walker, Iain

    2010-08-16T23:59:59.000Z

    Ventilation dilutes or removes indoor contaminants to reduce occupant exposure. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. The total ventilation rate is the most important factor in determining the exposure of occupants to given sources, but the zone- specific distribution of exhaust and supply air, and the mixing of ventilation air can have significant roles. Different types of ventilation systems will provide different amounts of mixing depending on several factors such as air leakage through the building envelope, air distribution systems and the location of sources and occupants. This paper reports recent results of investigations to determine the impact that air mixing has on exposures of residential occupants to prototypical contaminants of concern. Evaluations of existing field measurements and simulations reported in the literature are combined with new analyses to provide an integrated overview of the topic. The results show that for extreme cases additional mixing can be a significant factor but for typical homes looking at average exposures mixing is not helpful and can even make exposures worse.

  8. Application of CO{sub 2}-based demand-controlled ventilation using ASHRAE Standard 62: Optimizing energy use and ventilation

    SciTech Connect (OSTI)

    Schell, M.B. [Engelhard Sensor Technologies, Santa Barbara, CA (United States); Turner, S.; Shim, R.O. [Chelsea Group, Ltd., Delray Beach, FL (United States)

    1998-12-31T23:59:59.000Z

    CO{sub 2}-based demand-controlled ventilation (DCV), when properly applied in spaces where occupancies vary below design occupancy, can reduce unnecessary overventilation while implementing target per-person ventilation rates. A recent interpretation of ANSI/ASHRAE Standard 62-1989, Interpretation 1C 62-1989-27, has affirmed that carbon dioxide (CO{sub 2})-based demand-controlled ventilation (DCV) systems can use CO{sub 2} as an occupancy indicator to modulate ventilation below the maximum total outdoor air intake rate while still maintaining the required ventilation rate per person, provided that certain conditions are met. This paper, co-written by the author of the interpretation, provides guidelines on the application of CO{sub 2}-based DCV. In addition, a method is presented that allows reasonable estimates of the actual ventilation rate per person being effectively delivered to the space, based on comparing predicted CO{sub 2} ventilation levels with CO{sub 2} levels logged in an occupied space. Finally, a model is presented to evaluate various CO{sub 2}-based DCV strategies to predict their delivery of target per-person ventilation rates within the lag times required by the standard.

  9. The International Journal of Ventilation

    E-Print Network [OSTI]

    California at Davis, University of

    air quality and reducing energy required for heating, cooling, and ventilation. One application. Introduction Heating, cooling and ventilation can account for 50 percent of total building energy useThe International Journal of Ventilation Volume 12 Number 4 ISSN 1473 - 3315 March 2014 Contents

  10. Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems

    E-Print Network [OSTI]

    Wetter, Michael

    2010-01-01T23:59:59.000Z

    Austria, September 2006. Modelica As- sociation and Arsenalsystems. The ?exibility of Modelica has been T room in [° C]lss. AirConditioning - a Modelica li- o brary for dynamic

  11. Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems

    E-Print Network [OSTI]

    Wetter, Michael

    2010-01-01T23:59:59.000Z

    a model with prescribed heat input into the medium, i.e. ,heat and towers. The air inlet temperature is obtained from an inputan input signal. There is also a constant effectiveness heat

  12. Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

    SciTech Connect (OSTI)

    Sherman, Max H.; Walker, Iain S.

    2011-04-01T23:59:59.000Z

    Existing ventilation standards, including American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE) Standard 62.2, specify continuous operation of a defined mechanical ventilation system to provide minimum ventilation, with time-based intermittent operation as an option. This requirement ignores several factors and concerns including: other equipment such as household exhaust fans that might incidentally provide ventilation, negative impacts of ventilation when outdoor pollutant levels are high, the importance of minimizing energy use particularly during times of peak electricity demand, and how the energy used to condition air as part of ventilation system operation changes with outdoor conditions. Dynamic control of ventilation systems can provide ventilation equivalent to or better than what is required by standards while minimizing energy costs and can also add value by shifting load during peak times and reducing intake of outdoor air contaminants. This article describes the logic that enables dynamic control of whole-house ventilation systems to meet the intent of ventilation standards and demonstrates the dynamic ventilation system control concept through simulations and field tests of the Residential Integrated Ventilation-Energy Controller (RIVEC).

  13. HOSPITAL VENTILATION STANDARDS AND ENERGY CONSERVATION: A SUMMARY OF THE LITERATURE WITH CONCLUSIONS AND RECOMMENDATIONS, FY 78 FINAL REPORT

    E-Print Network [OSTI]

    DeRoos, R.L.

    2011-01-01T23:59:59.000Z

    on the premise that current hospital ventilation standardsand ,ventilation rates based on the premise of reducing

  14. Quantification of the relationship between pulmonary ventilation rate and vapor contaminant concentration in exposure profiles

    E-Print Network [OSTI]

    Horbal, Terrence Myron

    1982-01-01T23:59:59.000Z

    Concentration in Exposure Profiles (August 1982) Terrence Myron Horbal, B. S. University of New Haven Chairman of Advisory Committee: Harry J. Suggs It is believed that present methods used to ascertain worker exposure to airborne contaminants do not... must often function within an environment contaminated with airborne emissions. Air- borne contaminants can be of two types: gases or vapors which are completely dispersed in the air, and suspended solid particles or liquid droplets in the air...

  15. A novel target-type low pressure drop bidirectional optoelectronic air flow sensor for infant artificial ventilation: Measurement principle and static calibration

    SciTech Connect (OSTI)

    Saccomandi, Paola; Schena, Emiliano; Silvestri, Sergio [Faculty of Biomedical Engineering, University Campus Bio-Medico, Via Alvaro del Portillo, 21, 00128 Rome (Italy)

    2011-02-15T23:59:59.000Z

    An optoelectronic target-type volumetric air flow-rate transducer for bidirectional measurements is presented. The sensor is composed of a T-shaped target and two nominally identical LED-photodiode couples which are operated in differential mode. The sensitive surfaces of the photodiodes are differentially shadowed by the deflection of the target, which in turn depends on the gas flow-rate. The principle of operation is described in mathematical terms and the design parameters have been optimized in order to obtain the highest sensitivity along with minimal pressure drop and reduced dimensions. The sensor is placed in a 20 mm diameter hose and was tested with air flow-rate in the typical temperature range of mechanical ventilation between 20 and 40 deg. C. The theoretical model was validated through experiments carried out in the volumetric flow range from -7.0 to +7.0 l min{sup -1}. The nonlinear behavior allows sensitivities equal to 0.6 V l{sup -1} min for flow rates ranging from -2.0 to +2.0 l min{sup -1}, equal to 2.0 V l{sup -1} min for flow rates ranging from -3.0 to -2.0 l min{sup -1} and from +2.0 to +3.0 l min{sup -1}, up to 5.7 V l{sup -1} min at higher flow rates ranging from -7.0 to -3.0 l min{sup -1} and from +3.0 to +7.0 l min{sup -1}. The linear range extends from 3.0 to 7.0 l min{sup -1} with constant sensitivity equal to 5.7 V l{sup -1} min. The sensor is able to detect a flow-rate equal to 1.0 l min{sup -1} with a sensitivity of about 400 mV l{sup -1} min. The differential nature of the output minimizes the influence of the LEDs' power supply variations and allows to obtain a repeatability in the order of 3% of full scale output. The small pressure drop produced by the sensor placed in-line the fluid stream, of about 2.4 Pa at 7 l min{sup -1}, corresponds to a negligible fluid dynamic resistance lower than 0.34 Pa l{sup -1} min.

  16. Ventilation Based on ASHRAE 62.2

    E-Print Network [OSTI]

    Indoor Ventilation Based on ASHRAE 62.2 Arnold Schwarzenegger Governor California Energy Commission Ventilation (ASHRAE 62.2) Minimum Best Practices Guide - Exhaust-Only Ventilation Introduction: The California/ASHRAE Standard 62.2-2007, Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ASHRAE

  17. STATE OF CALIFORNIA MECHANICAL VENTILATION AND REHEAT

    E-Print Network [OSTI]

    STATE OF CALIFORNIA MECHANICAL VENTILATION AND REHEAT CEC-MECH-3C (Revised 08/09) CALIFORNIA ENERGY COMMISSION MECHANICAL VENTILATION AND REHEAT MECH-3C PROJECT NAME DATE MECHANICAL VENTILATION §121(b)2 REHEAT'D V.A. Max of D or G Design Ventilation Air cfm 50% of Design Zone Supply cfm B x 0.4 cfm/ft˛ Max

  18. Why We Ventilate

    SciTech Connect (OSTI)

    Logue, Jennifer M.; Sherman, Max H.; Price, Phil N.; Singer, Brett C.

    2011-09-01T23:59:59.000Z

    It is widely accepted that ventilation is critical for providing good indoor air quality (IAQ) in homes. However, the definition of"good" IAQ, and the most effective, energy efficient methods for delivering it are still matters of research and debate. This paper presents the results of work done at the Lawrence Berkeley National Lab to identify the air pollutants that drive the need for ventilation as part of a larger effort to develop a health-based ventilation standard. First, we present results of a hazard analysis that identified the pollutants that most commonly reach concentrations in homes that exceed health-based standards or guidelines for chronic or acute exposures. Second, we present results of an impact assessment that identified the air pollutants that cause the most harm to the U.S. population from chronic inhalation in residences. Lastly, we describe the implications of our findings for developing effective ventilation standards.

  19. air infiltration rates: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    into the wire with a maximum rate of rise ... Jadidian, Jouya 212 Estimating Energy Savings in Compressed Air Systems Texas A&M University - TxSpace Summary: -load power...

  20. Temperature stratification and air change effectiveness in a high cooling load office with two heat source heights in a combined chilled ceiling and displacement ventilation system

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred; Tully, Brad; Rimmer, Julian

    2012-01-01T23:59:59.000Z

    and displacement ventilation system. Submitted to Energy andand displacement ventilation system. Submitted to Energy andand displacement ventilation systems, Energy Build. 34 (

  1. A study of time-dependent responses of a mechanical displacement ventilation (DV) system and an underfloor air distribution (UFAD) system : building energy performance of the UFAD system

    E-Print Network [OSTI]

    Yu, Jong Keun

    2010-01-01T23:59:59.000Z

    Displacement Ventilation system . . . . . . . . . . 1.1.2responses of mechanical Displacement Ventilation system 2.1of Displacement Ventilation Systems . Experi- mental and

  2. Ventilation Model Report

    SciTech Connect (OSTI)

    V. Chipman; J. Case

    2002-12-20T23:59:59.000Z

    The purpose of the Ventilation Model is to simulate the heat transfer processes in and around waste emplacement drifts during periods of forced ventilation. The model evaluates the effects of emplacement drift ventilation on the thermal conditions in the emplacement drifts and surrounding rock mass, and calculates the heat removal by ventilation as a measure of the viability of ventilation to delay the onset of peak repository temperature and reduce its magnitude. The heat removal by ventilation is temporally and spatially dependent, and is expressed as the fraction of heat carried away by the ventilation air compared to the fraction of heat produced by radionuclide decay. One minus the heat removal is called the wall heat fraction, or the remaining amount of heat that is transferred via conduction to the surrounding rock mass. Downstream models, such as the ''Multiscale Thermohydrologic Model'' (BSC 2001), use the wall heat fractions as outputted from the Ventilation Model to initialize their post-closure analyses. The Ventilation Model report was initially developed to analyze the effects of preclosure continuous ventilation in the Engineered Barrier System (EBS) emplacement drifts, and to provide heat removal data to support EBS design. Revision 00 of the Ventilation Model included documentation of the modeling results from the ANSYS-based heat transfer model. Revision 01 ICN 01 included the results of the unqualified software code MULTIFLUX to assess the influence of moisture on the ventilation efficiency. The purposes of Revision 02 of the Ventilation Model are: (1) To validate the conceptual model for preclosure ventilation of emplacement drifts and verify its numerical application in accordance with new procedural requirements as outlined in AP-SIII-10Q, Models (Section 7.0). (2) To satisfy technical issues posed in KTI agreement RDTME 3.14 (Reamer and Williams 2001a). Specifically to demonstrate, with respect to the ANSYS ventilation model, the adequacy of the discretization (Section 6.2.3.1), and the downstream applicability of the model results (i.e. wall heat fractions) to initialize post-closure thermal models (Section 6.6). (3) To satisfy the remainder of KTI agreement TEF 2.07 (Reamer and Williams 2001b). Specifically to provide the results of post-test ANSYS modeling of the Atlas Facility forced convection tests (Section 7.1.2). This portion of the model report also serves as a validation exercise per AP-SIII.10Q, Models, for the ANSYS ventilation model. (4) To asses the impacts of moisture on the ventilation efficiency.

  3. Particle deposition in ventilation ducts

    SciTech Connect (OSTI)

    Sippola, Mark R.

    2002-09-01T23:59:59.000Z

    Exposure to airborne particles is detrimental to human health and indoor exposures dominate total exposures for most people. The accidental or intentional release of aerosolized chemical and biological agents within or near a building can lead to exposures of building occupants to hazardous agents and costly building remediation. Particle deposition in heating, ventilation and air-conditioning (HVAC) systems may significantly influence exposures to particles indoors, diminish HVAC performance and lead to secondary pollutant release within buildings. This dissertation advances the understanding of particle behavior in HVAC systems and the fates of indoor particles by means of experiments and modeling. Laboratory experiments were conducted to quantify particle deposition rates in horizontal ventilation ducts using real HVAC materials. Particle deposition experiments were conducted in steel and internally insulated ducts at air speeds typically found in ventilation ducts, 2-9 m/s. Behaviors of monodisperse particles with diameters in the size range 1-16 {micro}m were investigated. Deposition rates were measured in straight ducts with a fully developed turbulent flow profile, straight ducts with a developing turbulent flow profile, in duct bends and at S-connector pieces located at duct junctions. In straight ducts with fully developed turbulence, experiments showed deposition rates to be highest at duct floors, intermediate at duct walls, and lowest at duct ceilings. Deposition rates to a given surface increased with an increase in particle size or air speed. Deposition was much higher in internally insulated ducts than in uninsulated steel ducts. In most cases, deposition in straight ducts with developing turbulence, in duct bends and at S-connectors at duct junctions was higher than in straight ducts with fully developed turbulence. Measured deposition rates were generally higher than predicted by published models. A model incorporating empirical equations based on the experimental measurements was applied to evaluate particle losses in supply and return duct runs. Model results suggest that duct losses are negligible for particle sizes less than 1 {micro}m and complete for particle sizes greater than 50 {micro}m. Deposition to insulated ducts, horizontal duct floors and bends are predicted to control losses in duct systems. When combined with models for HVAC filtration and deposition to indoor surfaces to predict the ultimate fates of particles within buildings, these results suggest that ventilation ducts play only a small role in determining indoor particle concentrations, especially when HVAC filtration is present. However, the measured and modeled particle deposition rates are expected to be important for ventilation system contamination.

  4. Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

    E-Print Network [OSTI]

    2012-01-01T23:59:59.000Z

    Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

  5. Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating Ventilation and Air Conditioning (HVAC) system for the HIE-ISOLDE infrastructure

    E-Print Network [OSTI]

    2012-01-01T23:59:59.000Z

    Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating Ventilation and Air Conditioning (HVAC) system for the HIE-ISOLDE infrastructure

  6. H.N. Knudsen, P. Wargocki and J. Vondruskova (2006) "Effect of ventilation on perceived quality of air polluted

    E-Print Network [OSTI]

    2006-01-01T23:59:59.000Z

    rate. This applies both for the data collected in small-scale and in full-scale experiments significance. These experiments should be carried out under realistic full- scale conditions. Keywords: Human responses to IAQ 1 Introduction Good perceived indoor air quality can be obtained by a low

  7. Ventilating characteristics of a recirculating air-curtain laboratory exhaust hood

    E-Print Network [OSTI]

    Janes, Dale Floyd

    1978-01-01T23:59:59.000Z

    on either side of the hood were energized, it was impossible to obtain any semblance of uniformity in the air-curtain velocity across the hood front. The blastgates in the supply ducts on either side of the hood were adjusted within their operating range... in Project "n~ 30 The recording voltage meter was energized at the beginning of a data run, the hour was indicated on the chart and the meter was allowed to continue recording throughout the day. Continuous moni- toring of the voltage was desired...

  8. A scale model study of displacement ventilation with chilled ceilings

    E-Print Network [OSTI]

    Holden, Katherine J. A. (Katherine Joan Adrienne)

    1995-01-01T23:59:59.000Z

    Displacement ventilation is a form of air-conditioning which provides good air quality and some energy savings. The air quality is better than for a conventional mixed ventilation system. The maximum amount of cooling that ...

  9. Commissioning Residential Ventilation Systems: A Combined Assessment of

    E-Print Network [OSTI]

    Commissioning Residential Ventilation Systems: A Combined Assessment of Energy and Air Quality ventilation systems are being installed in new California homes. Few measurements are available of commissioning residential whole- house ventilation systems that are intended to comply

  10. Room air stratification in combined chilled ceiling and displacement ventilation systems.

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred; Tully, Brad; Rimmer, Julian

    2012-01-01T23:59:59.000Z

    0 and 73 W/m 2 [0-23.1 Btu/(h ft 2 )](based on radiant panelbetween 0 and 28 W/m 2 [0-8.9 Btu/(h ft 2 )] (based on roomand 76 W/m 2 (97.8 and 239.7 Btu/(h ft 2 )), DV airflow rate

  11. Modeling indoor exposures to VOCs and SVOCs as ventilation rates vary

    E-Print Network [OSTI]

    Parthasarathy, Srinandini

    2013-01-01T23:59:59.000Z

    Particle deposition and resuspension are modeled as a first-The deposition and resuspension rate constants, as well as

  12. Measuring OutdoorAir Intake Rates Using Electronic Velocity Sensors at Louvers and Downstream of Airflow Straighteners

    SciTech Connect (OSTI)

    Fisk, William; Sullivan, Douglas; Cohen, Sebastian; Han, Hwataik

    2008-10-01T23:59:59.000Z

    Practical and accurate technologies are needed for continuously measuring and controlling outdoor air (OA) intake rates in commercial building heating, ventilating, and air conditioning (HVAC) systems. This project evaluated two new measurement approaches. Laboratory experiments determined that OA flow rates were measurable with errors generally less than 10percent using electronic air velocity probes installed between OA intake louver blades or at the outlet face of louvers. High accuracy was maintained with OA flow rates as low as 15percent of the maximum for the louvers. Thus, with this measurement approach HVAC systems do not need separate OA intakes for minimum OA supply. System calibration parameters are required for each unique combination of louver type and velocity sensor location but calibrations are not necessary for each system installation. The research also determined that the accuracy of measuring OA flow rates with velocity probes located in the duct downstream of the intake louver was not improved by installing honeycomb airflow straighteners upstream of the probes. Errors varied with type of upstream louver, were as high as 100percent, and were often greater than 25percent. In conclusion, use of electronic air velocity probes between the blades of OA intake louvers or at the outlet face of louvers is a highly promising means of accurately measuring rates of OA flow into HVAC systems. The use of electronic velocity probes downstream of airflow straighteners is less promising, at least with the relatively small OA HVAC inlet systems employed in this research.

  13. Natural Ventilation for Energy Savings in California Commercial Buildings

    E-Print Network [OSTI]

    2014-01-01T23:59:59.000Z

    heating, ventilating and air conditioning survey of small2004) Workplace air-conditioning and health servicesventilating, and air-conditioning applications. Bauman, F. ,

  14. Ventilative cooling

    E-Print Network [OSTI]

    Graça, Guilherme Carrilho da, 1972-

    1999-01-01T23:59:59.000Z

    This thesis evaluates the performance of daytime and nighttime passive ventilation cooling strategies for Beijing, Shanghai and Tokyo. A new simulation method for cross-ventilated wind driven airflow is presented . This ...

  15. The Effects of Air Permeability, Background Ventilation and Lifestyle on Energy Performance, Indoor Air Quality and Risk of Condensation in Domestic Buildings

    E-Print Network [OSTI]

    Hashemi, Arman; Khatami, Narguess

    2015-04-08T23:59:59.000Z

    : London, UK, 2005. 34. EST. Energy Efficient Ventilation in Dwellings—A Guide for Specifiers: GPG268; Energy Saving Trust: London, UK, 2006. © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed...

  16. Scale model studies of displacement ventilation

    E-Print Network [OSTI]

    Okutan, Galip Mehmet

    1995-01-01T23:59:59.000Z

    Displacement ventilation is an air conditioning method that provides conditioned air to indoor environments with the goal to improve air quality while reducing energy consumption. This study investigates the performance ...

  17. Design of a Natural Ventilation System in the Dunhuang Museum

    E-Print Network [OSTI]

    Zhang, Y.; Guan, W.

    2006-01-01T23:59:59.000Z

    Fresh air and good air quality can be obtained by a natural ventilation system, to fulfill the requirement of near natural conditions for the psychological health of mankind. A natural ventilation system is an ecological, energy saving system...

  18. Study on Influencing Factors of Night Ventilation in Office Rooms

    E-Print Network [OSTI]

    Wang, Z.; Sun, X.

    2006-01-01T23:59:59.000Z

    A mathematical and physical model on night ventilation is set up. The fields of indoor air temperature, air velocity and thermal comfort are simulated using Airpak software. Some main influencing factors of night ventilation in office rooms...

  19. Improve Indoor Air Quality, Energy Consumption and Building Performance: Leveraging Technology to Improve All Three

    E-Print Network [OSTI]

    Wiser, D.

    2011-01-01T23:59:59.000Z

    in the most efficient way possible. However, maintaining optimum indoor air quality often seems to be in conflict with minimizing operating and energy costs. Conventional wisdom says the best IAQ strategy involves increasing ventilation rates. But outdoor air...

  20. Hysteresis effects in hybrid building ventilation

    E-Print Network [OSTI]

    Flynn, Morris R.

    = Heating, ventilation & air conditioning Buildings and energy consumption #12;· Notwithstanding this energy-breeze, displacement ventilation dissipate internal heat gains e.g. from kitchen stove · Wintertime: Spaces filledHysteresis effects in hybrid building ventilation Morris R. Flynn Dept. of Mechanical & Aerospace

  1. DEMAND CONTROLLED VENTILATION AND CLASSROOM VENTILATION

    E-Print Network [OSTI]

    Fisk, William J.

    2014-01-01T23:59:59.000Z

    for demand controlled ventilation in commercial buildings.The energy costs of classroom ventilation and some financialEstimating potential benefits of increased ventilation

  2. Impact of Residential Mechanical Ventilation on Energy Cost and Humidity Control

    SciTech Connect (OSTI)

    Martin, E.

    2014-01-01T23:59:59.000Z

    The DOE Building America program has been conducting research leading to cost effective high performance homes since the early 1990's. Optimizing whole house mechanical ventilation as part of the program's systems engineered approach to constructing housing has been an important subject of the program's research. Ventilation in residential buildings is one component of an effective, comprehensive strategy for creation and maintenance of a comfortable and healthy indoor air environment. The study described in this white paper is based on building energy modeling with an important focus on the indoor humidity impacts of ventilation. The modeling tools used were EnergyPlus version 7.1 (E+) and EnergyGauge USA (EGUSA). Twelve U.S. cities and five climate zones were represented. A total of 864 simulations (2*2*3*3*12= 864) were run using two building archetypes, two building leakage rates, two building orientations, three ventilation systems, three ventilation rates, and twelve climates.

  3. CONFIDENTIAL: DO NOT QUOTE 1 Equivalence in Ventilation and

    E-Print Network [OSTI]

    CONFIDENTIAL: DO NOT QUOTE 1 Equivalence in Ventilation and Indoor Air Quality M. H. Sherman, I ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum

  4. A. Buonomano, M. Sherman, USA: Analysis of residential hybrid ventilation performance in U.S. climates 1 Intern. Symposium on Building and Ductwork Air tightness

    E-Print Network [OSTI]

    passive ventilation systems to meet ASHRAE 62.2 requirements as a step in the process for optimizing hybrid ventilation systems. A brief review of the literature with reference to the passive and hybrid ventilation systems in residential building is presented. The review focuses on key aspects of ventilation

  5. Ventilation Model

    SciTech Connect (OSTI)

    H. Yang

    1999-11-04T23:59:59.000Z

    The purpose of this analysis and model report (AMR) for the Ventilation Model is to analyze the effects of pre-closure continuous ventilation in the Engineered Barrier System (EBS) emplacement drifts and provide heat removal data to support EBS design. It will also provide input data (initial conditions, and time varying boundary conditions) for the EBS post-closure performance assessment and the EBS Water Distribution and Removal Process Model. The objective of the analysis is to develop, describe, and apply calculation methods and models that can be used to predict thermal conditions within emplacement drifts under forced ventilation during the pre-closure period. The scope of this analysis includes: (1) Provide a general description of effects and heat transfer process of emplacement drift ventilation. (2) Develop a modeling approach to simulate the impacts of pre-closure ventilation on the thermal conditions in emplacement drifts. (3) Identify and document inputs to be used for modeling emplacement ventilation. (4) Perform calculations of temperatures and heat removal in the emplacement drift. (5) Address general considerations of the effect of water/moisture removal by ventilation on the repository thermal conditions. The numerical modeling in this document will be limited to heat-only modeling and calculations. Only a preliminary assessment of the heat/moisture ventilation effects and modeling method will be performed in this revision. Modeling of moisture effects on heat removal and emplacement drift temperature may be performed in the future.

  6. HOSPITAL VENTILATION STANDARDS AND ENERGY CONSERVATION: A SUMMARY OF THE LITERATURE WITH CONCLUSIONS AND RECOMMENDATIONS, FY 78 FINAL REPORT

    E-Print Network [OSTI]

    DeRoos, R.L.

    2011-01-01T23:59:59.000Z

    the largest problem facing the ventilation engineer; sourcesthe heating and ventilation was already a problem. 6 In thethe hospital odor problem with regards to ventilation rates.

  7. Project title: Natural ventilation, solar heating and integrated low-energy building design

    E-Print Network [OSTI]

    2009-07-10T23:59:59.000Z

    greenhouse gas emissions from office buildings CMI E-Newsletter Issue 7 BP announces funding for CMI project on integrated low-energy building design No air conditioning, no sweat! Sustainable Building Design: Application Of Natural Ventilation Short... , such as China, where new buildings are being constructed at a rate far in excess of the level of development in developed countries, and where energy is relatively expensive. More Information For further information, please visit the Natural Ventilation...

  8. INDOOR AIR QUALITY MEASUREMENTS IN ENERGY EFFICIENT BUILDINGS

    E-Print Network [OSTI]

    Hollowell, C.D.

    2011-01-01T23:59:59.000Z

    incorporating energy efficient designs. Indoor air qualityincorporating energy efficient designs. In the future, theenergy efficient ventilation standards and ventilation designs

  9. Air temperature thresholds for indoor comfort and perceived air quality

    E-Print Network [OSTI]

    Zhang, Hui; Edward, Arens; Pasut, Wilmer

    2012-01-01T23:59:59.000Z

    in the Netherlands, Indoor Air 2, 127 – 136. BuildingPaliaga, G. (2009) Moving air for comfort. ASHRAE Journal,ventilation system on perceived air quality, Indoor Air

  10. Sensitivity of Tropical Cyclone Intensity to Ventilation in an Axisymmetric Model

    E-Print Network [OSTI]

    Tang, Brian

    The sensitivity of tropical cyclone intensity to ventilation of cooler, drier air into the inner core is examined using an axisymmetric tropical cyclone model with parameterized ventilation. Sufficiently strong ventilation ...

  11. Optimal decision making in ventilation control Andrew Kusiak*, Mingyang Li

    E-Print Network [OSTI]

    Kusiak, Andrew

    by heating, ventilating and air- conditioning (HVAC) systems. According to published statistics, HVAC systemsOptimal decision making in ventilation control Andrew Kusiak*, Mingyang Li Department of Mechanical Accepted 24 July 2009 Available online 15 August 2009 Keywords: Ventilation Air quality Multi

  12. Modeling buoyancy-driven airflow in ventilation shafts

    E-Print Network [OSTI]

    Ray, Stephen D. (Stephen Douglas)

    2012-01-01T23:59:59.000Z

    Naturally ventilated buildings can significantly reduce the required energy for cooling and ventilating buildings by drawing in outdoor air using non-mechanical forces. Buoyancy-driven systems are common in naturally ...

  13. Evaluation of Ventilation Strategies in New Construction Multifamily Buildings

    SciTech Connect (OSTI)

    Maxwell, S.; Berger, D.; Zuluaga, M.

    2014-07-01T23:59:59.000Z

    In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the 'fresh' air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the 'normal leakage paths through the building envelope' disappear. CARB researchers have found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. Product performance data are based on laboratory tests, and the assumption is that products will perform similarly in the field. Proper application involves matching expected performance at expected building pressures, but there is no guarantee that those conditions will exist consistently in the finished building. This research effort, which included several weeks of building pressure monitoring, sought to provide field validation of system performance. The performance of four substantially different strategies for providing make-up air to apartments was evaluated.

  14. Spatial analysis of air pollution and cancer incidence rates in Haifa Bay, Israel Ori Eitan a

    E-Print Network [OSTI]

    Spatial analysis of air pollution and cancer incidence rates in Haifa Bay, Israel Ori Eitan with historically high air pollution levels. This work tests whether persistent spatial patterns of metrics of chronic exposure to air pollutants are associated with the observed patterns of cancer incidence rates

  15. ASHRAE and residential ventilation

    SciTech Connect (OSTI)

    Sherman, Max H.

    2003-10-01T23:59:59.000Z

    In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality creates health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the logical place to provide leadership. This leadership has been demonstrated most recently by the publication of the first nationally recognized standard on ventilation in homes, ASHRAE Standard 62.2-2003, which builds on work that has been part of ASHRAE for many years and will presumably continue. Homeowners and occupants, which includes virtually all of us, will benefit from the application of Standard 62.2 and use of the top ten list. This activity is exactly the kind of benefit to society that the founders of ASHRAE envisioned and is consistent with ASHRAE's mission and vision. ASHRAE members should be proud of their Society for taking leadership in residential ventilation.

  16. Test Plan to Evaluate the Relationship Among IAQ, Comfort, Moisture, and Ventilation in Humid Climates

    SciTech Connect (OSTI)

    Widder, Sarah H.; Martin, Eric

    2013-03-15T23:59:59.000Z

    This experimental plan describes research being conducted by Pacific Northwest National Laboratory (PNNL), in coordinatation with Florida Solar Energy Center (FSEC), Florida HERO, and Lawrence Berkeley National Laboratory (LBNL) to evaluate the impact of ventilation rate on interior moisture levels, temperature distributions, and indoor air contaminant concentrations. Specifically, the research team will measure concentrations of indoor air contaminants, ventilation system flow rates, energy consumption, and temperature and relative humidity in ten homes in Gainesville, FL to characterize indoor pollutant levels and energy consumption associated with the observed ventilation rates. PNNL and FSEC have collaboratively prepared this experimental test plan, which describes background and context for the proposed study; the experimental design; specific monitoring points, including monitoring equipment, and sampling frequency; key research questions and the associated data analysis approach; experimental logistics, including schedule, milestones, and team member contact information; and clearly identifies the roles and responsibilities of each team in support of project objectives.

  17. Industrial Ventilation Statistics Confirm Energy Savings Opportunity

    E-Print Network [OSTI]

    Litomisky, A.

    2006-01-01T23:59:59.000Z

    is based on installed on-demand ventilation systems, where sensors and PLC are installed with each system, so data is easily collected. Another critical factor for effective dust collecting is proper air velocities in duct system. Having measured air... velocities at drops and at the main ducts of existing classical industrial ventilation designs in 90 factories, 130 systems, and 1000 drops, we have found that only a minimum of air velocities are in the recommended range. There is a striking dichotomy...

  18. Laser Sheet Light Flow Visualization For Evaluating Room Air Flows From

    E-Print Network [OSTI]

    ;Introduction Forced air heating and cooling systems and whole house ventilation systems deliver air

  19. Carbon-dioxide-controlled ventilation study

    SciTech Connect (OSTI)

    McMordie, K.L.; Carroll, D.M.

    1994-05-01T23:59:59.000Z

    The In-House Energy Management (IHEM) Program has been established by the U.S. Department of Energy to provide funds to federal laboratories to conduct research on energy-efficient technology. The Energy Sciences Department of Pacific Northwest Laboratory (PNL) was tasked by IHEM to research the energy savings potential associated with reducing outdoor-air ventilation of buildings. By monitoring carbon dioxide (CO{sub 2}) levels in a building, outdoor air provided by the heating, ventilating, and air-conditioning (HVAC) system can be reduced to the percentage required to maintain satisfactory CO{sub 2} levels rather than ventilating with a higher outdoor-air percentage based on an arbitrary minimum outdoor-air setting. During summer months, warm outdoor air brought into a building for ventilation must be cooled to meet the appropriate cooling supply-air temperature, and during winter months, cold outdoor air must be heated. By minimizing the amount of hot or cold outdoor air brought into the HVAC system, the supply air requires less cooling or heating, saving energy and money. Additionally, the CO{sub 2} levels in a building can be monitored to ensure that adequate outdoor air is supplied to a building to maintain air quality levels. The two main considerations prior to implementing CO{sub 2}-based ventilation control are its impact on energy consumption and the adequacy of indoor air quality (IAQ) and occupant comfort. To address these considerations, six portable CO{sub 2} monitors were placed in several Hanford Site buildings to estimate the adequacy of office/workspace ventilation. The monitors assessed the potential for reducing the flow of outdoor-air to the buildings. A candidate building was also identified to monitor various ventilation control strategies for use in developing a plan for implementing and assessing energy savings.

  20. air kerma rate: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    compressed air with pressure regulators to purge control cabinets. Finally, a review of compressor technologies with typical cfm, pressure ranges, and price... Herron, D. J. 414...

  1. air kerma rates: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    compressed air with pressure regulators to purge control cabinets. Finally, a review of compressor technologies with typical cfm, pressure ranges, and price... Herron, D. J. 414...

  2. Risk Factors in Heating, Ventilating, and Air-Conditioning Systemsfor Occupant Symptoms in U.S. Office Buildings: the EPA BASE Study

    SciTech Connect (OSTI)

    Mendell, M.J.; Lei-Gomez, Q.; Mirer, A.; Seppanen, O.; Brunner, G.

    2006-10-01T23:59:59.000Z

    Nonspecific building-related symptoms among occupants of modern office buildings worldwide are common and may be associated with important reductions in work performance, but their etiology remains uncertain. Characteristics of heating, ventilating, and air-conditioning (HVAC) systems in office buildings that increase risk of indoor contaminants or reduce effectiveness of ventilation may cause adverse exposures and subsequent increase in these symptoms among occupants. We analyzed data collected by the U.S. EPA from a representative sample of 100 large U.S. office buildings--the Building Assessment and Survey Evaluation (BASE) study--using multivariate logistic regression models with generalized estimating equations adjusted for potential personal and building confounders. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) for associations between seven building-related symptom outcomes and selected HVAC system characteristics. Among factors of HVAC design or configuration: Outdoor air intakes less than 60 m above the ground were associated with approximately doubled odds of most symptoms assessed. Sealed (non-operable) windows were associated with increases in skin and eye symptoms (ORs= 1.9, 1.3, respectively). Outdoor air intake without an intake fan was associated with an increase in eye symptoms (OR=1.7). Local cooling coils were associated with increased headache (OR=1.5). Among factors of HVAC condition, maintenance, or operation: the presence of humidification systems in good condition was associated with an increase in headache (OR=1.4), whereas the presence of humidification systems in poor condition was associated with increases in fatigue/difficulty concentrating, as well as upper respiratory symptoms (ORs=1.8, 1.5). No regularly scheduled inspections for HVAC components was associated with increased eye symptoms, cough and upper respiratory symptoms (ORs=2.2, 1.6, 1.5). Less frequent cleaning of cooling coils or drip pans was associated with increased headache (OR=1.6). Fair or poor condition of duct liner was associated with increased upper respiratory symptoms (OR=1.4). Most of the many potential risk factors assessed here had not been investigated previously, and associations found with single symptoms may have been by chance, including several associations that were the reverse of expected. Risk factors newly identified in these analyses that deserve attention include outdoor air intakes less than 60 m above the ground, lack of operable windows, poorly maintained humidification systems, and lack of scheduled inspection for HVAC systems. Infrequent cleaning of cooling coils and drain pans were associated with increases in several symptoms in these as well as prior analyses of BASE data. Replication of these findings is needed, using more objective measurements of both exposure and health response. Confirmation of the specific HVAC factors responsible for increased symptoms in buildings, and development of prevention strategies could have major public health and economic benefits worldwide.

  3. Seasonal Variation in Monthly Average Air Change Rates Using Passive Tracer Gas Measurements

    E-Print Network [OSTI]

    Hansen, René Rydhof

    of indoor air pollution sources. Concurrently, great efforts are made to make buildings energy efficient 1970s, while less attention has been paid to IAQ. Insufficient venting of indoor air pollutantsSeasonal Variation in Monthly Average Air Change Rates Using Passive Tracer Gas Measurements Marie

  4. Worker performance and ventilation in a call center: Analyses of work performance data for registered nurses

    SciTech Connect (OSTI)

    Federspiel, C.C.; Fisk, W.J.; Price, P.N.; Liu, G.; Faulkner, D.; Dibartolomeo, D.L.; Sullivan, D.P.; Lahiff, M.

    2004-05-01T23:59:59.000Z

    We investigated the relationship between ventilation rates and individual work performance in a call center, and controlled for other factors of the indoor environment. We randomized the position of the outdoor air control dampers, and measured ventilation rate, differential (indoor minus outdoor) carbon dioxide ({Delta}CO{sub 2}) concentration, supply air velocity, temperature, humidity, occupant density, degree of under-staffing, shift length, time of day, and time required to complete two different work performance tasks (talking with clients and post-talk wrap-up to process information). {Delta}CO{sub 2} concentrations ranged from 13 to 611 ppm. We used multi-variable regression to model the association between the predictors and the responses. We found that agents performed talk tasks fastest when the ventilation rate was highest, but that the relationship between talk performance and ventilation was not strong or monotonic. We did not find a statistically significant association between wrap-up performance and ventilation rate. Agents were slower at the wrap-up task when the temperature was high (>25.4 C). Agents were slower at wrap-up during long shifts and when the call center was under-staffed.

  5. Validation of CFD Simulations for Natural Ventilation , Camille Allocca1

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    1 Validation of CFD Simulations for Natural Ventilation Yi Jiang1 , Camille Allocca1 , and Qingyan ventilation, which may provide occupants with good indoor air quality and a high level of thermal comfort-driven and buoyancy-drive natural ventilation. The validation of the CFD models used the experimental data of wind

  6. MINING VENTILATION CONTROL: A NEW INDUSTRIAL CASE FOR WIRELESS AUTOMATION

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    % of the energy consumed by the mining process goes into the ventilation (including heating the air). It is clearMINING VENTILATION CONTROL: A NEW INDUSTRIAL CASE FOR WIRELESS AUTOMATION E. Witrant1, A. D This paper serves as an introduction to Special Session on Ventilation Control in Large-Scale Systems. We de

  7. Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-11-01T23:59:59.000Z

    The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent). The original ventilation design for the project was provided by a local engineer and consisted of a single large heat recovery ventilator (HRV) located in a mechanical room in the basement with a centralized duct system providing supply air to the main living space and exhausting stale air from the single bathroom in each apartment. This design was deemed to be far too costly to install and operate for several reasons: the large central HRV was oversized and the specified flows to each apartment were much higher than the ASHRAE 62.2 rate; an extensive system of ductwork, smoke and fire dampers, and duct chases were specified; ductwork required a significant area of dropped ceilings; and the system lacked individual ventilation control in the apartments

  8. Prediction of Room Air Diffusion for Reduced Diffuser Flow Rates

    E-Print Network [OSTI]

    Gangisetti, Kavita

    2011-02-22T23:59:59.000Z

    With the ever-increasing availability of high performance computing facilities, numerical simulation through Computational Fluid Dynamics (CFD) is increasingly used to predict the room air distribution. CFD is becoming an important design...

  9. air flow rates: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 41 Overheat Instability in an Ascending Moist Air Flow as a Mechanism of Hurricane Formation...

  10. air flow rate: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 41 Overheat Instability in an Ascending Moist Air Flow as a Mechanism of Hurricane Formation...

  11. Summary of Workshop: Barriers to Energy Efficient Residential Ventilation

    E-Print Network [OSTI]

    Sherman, Max

    2008-01-01T23:59:59.000Z

    quality problems. Traditionally residential ventilation wasquality problems such as moisture. Residential ventilationventilation air is only one way of tackling the R H problem

  12. Buoyancy-Driven Ventilation of Hydrogen from Buildings: Laboratory Test and Model Validation

    SciTech Connect (OSTI)

    Barley, C. D.; Gawlik, K.

    2009-05-01T23:59:59.000Z

    Passive, buoyancy-driven ventilation is one approach to limiting hydrogen concentration. We explored the relationship between leak rate, ventilation design, and hydrogen concentrations.

  13. Midlevel ventilation's constraint on tropical cyclone intensity

    E-Print Network [OSTI]

    Tang, Brian Hong-An

    2010-01-01T23:59:59.000Z

    Midlevel ventilation, or the flux of low-entropy air into the inner core of a tropical cyclone (TC), is a hypothesized mechanism by which environmental vertical wind shear can constrain a TC's intensity. An idealized ...

  14. Midlevel Ventilation's Constraint on Tropical Cyclone Intensity

    E-Print Network [OSTI]

    Tang, Brian Hong-An

    Midlevel ventilation, or the flux of low-entropy air into the inner core of a tropical cyclone (TC), is a hypothesized mechanism by which environmental vertical wind shear can constrain a tropical cyclone’s intensity. An ...

  15. Floor-supply displacement ventilation system

    E-Print Network [OSTI]

    Kobayashi, Nobukazu, 1967-

    2001-01-01T23:59:59.000Z

    Research on indoor environments has received more attention recently because reports of symptoms and other health complaints related to indoor environments have been increasing. Heating, ventilating, and air-conditioning ...

  16. Development of a Residential Integrated Ventilation Controller

    SciTech Connect (OSTI)

    Staff Scientist; Walker, Iain; Sherman, Max; Dickerhoff, Darryl

    2011-12-01T23:59:59.000Z

    The goal of this study was to develop a Residential Integrated Ventilation Controller (RIVEC) to reduce the energy impact of required mechanical ventilation by 20percent, maintain or improve indoor air quality and provide demand response benefits. This represents potential energy savings of about 140 GWh of electricity and 83 million therms of natural gas as well as proportional peak savings in California. The RIVEC controller is intended to meet the 2008 Title 24 requirements for residential ventilation as well as taking into account the issues of outdoor conditions, other ventilation devices (including economizers), peak demand concerns and occupant preferences. The controller is designed to manage all the residential ventilation systems that are currently available. A key innovation in this controller is the ability to implement the concept of efficacy and intermittent ventilation which allows time shifting of ventilation. Using this approach ventilation can be shifted away from times of high cost or high outdoor pollution towards times when it is cheaper and more effective. Simulations, based on the ones used to develop the new residential ventilation requirements for the California Buildings Energy code, were used to further define the specific criteria and strategies needed for the controller. These simulations provide estimates of the energy, peak power and contaminant improvement possible for different California climates for the various ventilation systems. Results from a field test of the prototype controller corroborate the predicted performance.

  17. Infiltration in ASHRAE's Residential Ventilation Standards

    SciTech Connect (OSTI)

    Sherman, Max

    2008-10-01T23:59:59.000Z

    The purpose of ventilation is to dilute or remove indoor contaminants that an occupant could be exposed to. It can be provided by mechanical or natural means. ASHRAE Standards including standards 62, 119, and 136 have all considered the contribution of infiltration in various ways, using methods and data from 20 years ago. The vast majority of homes in the United States and indeed the world are ventilated through natural means such as infiltration caused by air leakage. Newer homes in the western world are tight and require mechanical ventilation. As we seek to provide acceptable indoor air quality at minimum energy cost, it is important to neither over-ventilate norunder-ventilate. Thus, it becomes critically important to correctly evaluate the contribution infiltration makes to both energy consumption and equivalent ventilation. ASHRAE Standard 62.2 specifies how much mechanical ventilation is considered necessary to provide acceptable indoor air quality, but that standard is weak on how infiltration can contribute towards meeting the total requirement. In the past ASHRAE Standard 136 was used to do this, but new theoretical approaches and expanded weather data have made that standard out of date. This article will describe how to properly treat infiltration as an equivalent ventilation approach and then use new data and these new approaches to demonstrate how these calculations might be done both in general and to update Standard 136.

  18. Demand Controlled Ventilation for Improved Humidity Control

    E-Print Network [OSTI]

    Rogers, J. K.

    1996-01-01T23:59:59.000Z

    Demand Controlled Ventilation for Improved Humidity Control James K. Rogers, P.E. One Blacksmith Road Chelmsford, Massachusetts ABSTRACT Recently introduced technology makes it possible to continuously monitor for humidity in numerous... is brought in for ventilation. The high "latent load" inherent in this hot, humid outside air is often the reason for installing excess chiller capacity and the cause of peak power demands. Recent concerns over poor indoor air quality (IAQ) due...

  19. Oceanic ventilation and biogeochemical cycling: Understanding the physical mechanisms that produce realistic distributions of tracers and

    E-Print Network [OSTI]

    Matsumoto, Katsumi

    Oceanic ventilation and biogeochemical cycling: Understanding the physical mechanisms that produce circulation support different rates of ventilation, which in turn produce different distributions. Matsumoto, J. L. Sarmiento, R. D. Slater, and P. S. Swathi (2004), Oceanic ventilation and biogeochemical

  20. Why We Ventilate

    E-Print Network [OSTI]

    Logue, Jennifer M.

    2012-01-01T23:59:59.000Z

    source emission rate of acrolein in residential indoor air.Exposure Acetaldehyde Acrolein Benzene Butadiene, 1,3-Acute Exposure Concerns Acrolein Chloroform Carbon Monoxide

  1. Air Exchange Rates in New Energy-Efficient Manufactured Housing

    E-Print Network [OSTI]

    Hadley, D. L.; Bailey, S. A.

    1990-01-01T23:59:59.000Z

    . The RCDP homes appear to be slightly tighter than the CP-1 homes, and significantly tighter than the CP-2 home sample. Table 3 Manufactured Homes Air Leakage Test Results ELA (in2) ACH -50 Mean St. Dev Mean St. Dev RCDP 94 29 6.0 1.6 CP-2 130 41 9...

  2. Proceedings of the Intern. Conference on Passive and Low Energy Architecture (PLEA), Toulouse (2002) 577 Cost efficiency of ventilation systems

    E-Print Network [OSTI]

    Gieseler, Udo D. J.

    2002-01-01T23:59:59.000Z

    ) 577 Cost efficiency of ventilation systems for low-energy buildings with earth-to-air heat exchange residential low-energy building are simulated for different ventilation systems with earth-to-air heat, simulation 1 Author to whom correspondence should be addressed. 1) VENTILATION SYSTEMS Ventilation systems

  3. Value impact analysis of Generic Issue 143, Availability of Heating, Ventilation, Air Conditioning (HVAC) and Chilled Water Systems

    SciTech Connect (OSTI)

    Daling, P.M.; Marler, J.E.; Vo, T.V.; Phan, H.; Friley, J.R. [Pacific Northwest Lab., Richland, WA (United States)

    1993-11-01T23:59:59.000Z

    This study evaluates the values (benefits) and impacts (costs) associated with potential resolutions to Generic Issue 143, ``Availability of HVAC and Chilled Water Systems.`` The study identifies vulnerabilities related to failures of HVAC, chilled water, and room cooling systems; develops estimates of room heatup rates and safety-related equipment vulnerabilities following losses of HVAC/room cooler systems; develops estimates of the core damage frequencies and public risks associated with failures of these systems; develops three proposed resolution strategies to this generic issue; and performs a value/impact analysis of the proposed resolutions. Existing probabilistic risk assessments for four representative plants, including one plant from each vendor, form the basis for the core damage frequency and public risk calculations. Both internal and external events were considered. It was concluded that all three proposed resolution strategies exceed the $1,000/person-rem cost-effectiveness ratio. Additional evaluations were performed to develop ``generic`` insights on potential design-related and configuration-related vulnerabilities and potential high-frequency ({approximately}1E-04/RY) accident sequences that involve failures of HVAC/room cooling functions. It was concluded that, although high-frequency accident sequences may exist at some plants, these high-frequency sequences are plant-specific in nature or have been resolved through hardware and/or operational changes. The plant-specific Individual Plant Examinations are an effective vehicle for identification and resolution of these plant-specific anomalies and hardware configurations.

  4. ENERGY ANALYSISF FOR WORKSHOPS WITH FLOOR-SUPPLY DISPLACEMENT VENTILATION UNDER THE U.S. CLIMATES

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    1 ENERGY ANALYSISF FOR WORKSHOPS WITH FLOOR-SUPPLY DISPLACEMENT VENTILATION UNDER THE U.S. CLIMATES ventilation systems are better than mixing ventilation systems. The benefits include indoor air quality. This research compared the energy use of a floor-supply displacement ventilation system in a large industrial

  5. Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

    E-Print Network [OSTI]

    Sherman, Max H.

    2011-01-01T23:59:59.000Z

    2007. Review of residential ventilation technologies. HVAC&Rof intermittent ventilation for providing acceptable indoorResidential Integrated Ventilation Controller. Energy

  6. Lobe-based Estimating Ventilation and Perfusion from 3D CT scans of the Lungs

    E-Print Network [OSTI]

    Warren, Joe

    Lobe-based Estimating Ventilation and Perfusion from 3D CT scans of the Lungs Travis McPhail Joe are the ventilation (air flow) and perfusion (blood flow) in the patient's lungs. Given the flow of air and blood as possible. The current state of the art technology for assessing the ventilation in a patient's lungs

  7. Diagnostics and Measurements of Infiltration and Ventilation Systems in High-Rise Apartment Buildings

    E-Print Network [OSTI]

    Diamond, Richard

    Diagnostics and Measurements of Infiltration and Ventilation Systems in High-Rise Apartment without compromising air quality? We have been studying the air flows and ventilation systems in high systems that are neither efficient nor deliver satisfactory ventilation. Frequent problems include

  8. On The Valuation of Infiltration towards Meeting Residential Ventilation Needs

    SciTech Connect (OSTI)

    Sherman, Max H.

    2008-09-01T23:59:59.000Z

    The purpose of ventilation is dilute or remove indoor contaminants that an occupant is exposed to. It can be provided by mechanical or natural means. In most homes, especially existing homes, infiltration provides the dominant fraction of the ventilation. As we seek to provide acceptable indoor air quality at minimum energy cost, it is important to neither over-ventilate nor under-ventilate. Thus, it becomes critically important to correctly evaluate the contribution infiltration makes to both energy consumption and equivalent ventilation. ASHRAE Standards including standards 62, 119, and 136 have all considered the contribution of infiltration in various ways, using methods and data from 20 years ago.

  9. Estimated costs of ventilation systems complying with the HUD ventilation standard for manufactured homes

    SciTech Connect (OSTI)

    Miller, J.D.; Conner, C.C.

    1993-11-01T23:59:59.000Z

    At the request of the US Department of Housing and Urban Development (HUD), the Pacific Northwest Laboratory estimated the material, labor, and operating costs for ventilation equipment needed for compliance with HUD`s proposed revision to the ventilation standard for manufactured housing. This was intended to bound the financial impacts of the ventilation standard revision. Researchers evaluated five possible prototype ventilation systems that met the proposed ventilation requirements. Of those five, two systems were determined to be the most likely used by housing manufacturers: System 1 combines a fresh air duct with the existing central forced-air system to supply and circulate fresh air to conditioned spaces. System 2 uses a separate exhaust fan to remove air from the manufactured home. The estimated material and labor costs for these two systems range from $200 to $300 per home. Annual operating costs for the two ventilation systems were estimated for 20 US cities. The estimated operating costs for System 1 ranged from $55/year in Las Vegas, Nevada, to $83/year in Bismarck, North Dakota. Operating costs for System 2 ranged from a low of $35/year in Las Vegas to $63/year in Bismarck. Thus, HUD`s proposed increase in ventilation requirements will add less than $100/year to the energy cost of a manufactured home.

  10. Experimental Study of Ventilation Performance in Laboratories with Chemical Spills

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    1 Experimental Study of Ventilation Performance in Laboratories with Chemical Spills Mingang Chemical spills occur frequently in laboratories. The current ventilation code for laboratories recommends a ventilation rate of 12 ACH for maintaining a safe laboratory environment. On the other hand, the energy saving

  11. SURFACE CIRCULATION AND VENTILATION Lynne D. Talley(1)

    E-Print Network [OSTI]

    Talley, Lynne D.

    SURFACE CIRCULATION AND VENTILATION Lynne D. Talley(1) , Rana Fine(2) , Rick Lumpkin (3) , Nikolai by high frequency radars. Ventilation and upwelling processes connect the surface layer and underlying quantitative information on formation rates and residence times, and compelling evidence of decadal ventilation

  12. Recommended Ventilation Strategies for Energy-Efficient Production Homes

    SciTech Connect (OSTI)

    Roberson, J.; Brown, R.; Koomey, J.; Warner, J.; Greenberg, S.

    1998-12-01T23:59:59.000Z

    This report evaluates residential ventilation systems for the U.S. Environmental Protection Agency's (EPA's) ENERGY STAR{reg_sign} Homes program and recommends mechanical ventilation strategies for new, low-infiltration, energy-efficient, single-family, ENERGY STAR production (site-built tract) homes in four climates: cold, mixed (cold and hot), hot humid, and hot arid. Our group in the Energy Analysis Department at Lawrence Berkeley National Lab compared residential ventilation strategies in four climates according to three criteria: total annualized costs (the sum of annualized capital cost and annual operating cost), predominant indoor pressure induced by the ventilation system, and distribution of ventilation air within the home. The mechanical ventilation systems modeled deliver 0.35 air changes per hour continuously, regardless of actual infiltration or occupant window-opening behavior. Based on the assumptions and analysis described in this report, we recommend independently ducted multi-port supply ventilation in all climates except cold because this strategy provides the safety and health benefits of positive indoor pressure as well as the ability to dehumidify and filter ventilation air. In cold climates, we recommend that multi-port supply ventilation be balanced by a single-port exhaust ventilation fan, and that builders offer balanced heat-recovery ventilation to buyers as an optional upgrade. For builders who continue to install forced-air integrated supply ventilation, we recommend ensuring ducts are airtight or in conditioned space, installing a control that automatically operates the forced-air fan 15-20 minutes during each hour that the fan does not operate for heating or cooling, and offering ICM forced-air fans to home buyers as an upgrade.

  13. Direct retrieval of stratospheric CO2 infrared cooling rate profiles from AIRS data

    E-Print Network [OSTI]

    Liou, K. N.

    of heating and cooling may be warranted. The largest infrared cooling takes place in the stratosphereDirect retrieval of stratospheric CO2 infrared cooling rate profiles from AIRS data D. R. Feldman,1 infrared cooling rate profiles, originally developed by Liou and Xue (1988) through application

  14. Saving energy and improving IAQ through application of advanced air cleaning technologies

    SciTech Connect (OSTI)

    Fisk, W.J; Destaillats, H.; Sidheswaran, M.A.

    2011-03-01T23:59:59.000Z

    In the future, we may be able use air cleaning systems and reduce rates of ventilation (i.e., reduce rates of outdoor air supply) to save energy, with indoor air quality (IAQ) remaining constant or even improved. The opportunity is greatest for commercial buildings because they usually have a narrower range of indoor pollutant sources than homes. This article describes the types of air cleaning systems that will be needed in commercial buildings.

  15. ASHRAE's Residential Ventilation Standard: Exegesis of Proposed Standard 62.2

    E-Print Network [OSTI]

    Sherman, M.

    2000-01-01T23:59:59.000Z

    In February 2000, ASHRAE's Standard Project Committee on "Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings", SPC 62.2P7 recommended ASHRAE's first complete standard on residential ventilation for public review...

  16. ASHRAE's Residential Ventilation Standard: Exegesis of Proposed Standard 62.2 

    E-Print Network [OSTI]

    Sherman, M.

    2000-01-01T23:59:59.000Z

    In February 2000, ASHRAE's Standard Project Committee on "Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings", SPC 62.2P7 recommended ASHRAE's first complete standard on residential ventilation ...

  17. air void system: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    18 Ventilation Air Preconditioning Systems Texas A&M University - TxSpace Summary: with individual functions, with the ventilation coil optimized for moisture removal and the...

  18. Ventilation and Infiltration in High-Rise Apartment Buildings Richard C. Diamond, Helmut E. Feustel and Darryl J. Dickerhoff

    E-Print Network [OSTI]

    Diamond, Richard

    1 Ventilation and Infiltration in High-Rise Apartment Buildings Richard C. Diamond, Helmut E to characterize the ventilation rates for the individual apartments. Parametric simulations were performed flow simulations suggest that the ventilation to the individual units varies considerably

  19. Traffic-related air pollution exposures and changes in heart rate variability in Mexico City: A panel study

    E-Print Network [OSTI]

    2013-01-01T23:59:59.000Z

    participated in the Mexico City Air Pollution Campaign [33].as part of the Mexico City Air Pollution Campaign. In 2004,pollution, PM 2.5 , Ozone, Heart rate variability, Mexico

  20. ENERGY IMPACTS OF VARIOUS RESIDENTIAL MECHANICAL VENTILATION STRATEGIES

    E-Print Network [OSTI]

    Vieira, R.; Parker, D.; Lixing, G.; Wichers, M.

    ENERGY IMPACTS OF VARIOUS RESIDENTIAL MECHANICAL VENTILATION STRATEGIES Robin K. Vieira, Buildings. Research Division Director Danny S. Parker Principal Research Scientist Lixing Gu Principal Research Engineer Michael Wichers... into the homes. Many of these strategies utilize the central air handler fan from the HVAC system to ventilate when the system runs. Controllers can be purchased to force the air to enter for minimum periods of time or to shut off outside air dampers after...

  1. Indoor-Outdoor Air Leakage of Apartments and Commercial Buildings

    E-Print Network [OSTI]

    Price, P.N.

    2011-01-01T23:59:59.000Z

    pathways other than a ventilation system. The term C in thepathways other than a ventilation system. Air flow acrossInfiltration and Ventilation Systems in High-Rise Apartment

  2. Development of a Residential Integrated Ventilation Controller

    E-Print Network [OSTI]

    Walker, Iain

    2013-01-01T23:59:59.000Z

    Comparative Evaluation of Ventilation Systems. ” ASHRAEChimneys for Residential Ventilation. ” AIVC 25 Conference.1995. “Controlled Ventilation Options for Builders. ” Energy

  3. Proposal for the award of a contract for the design, supply, installation and commissioning of a ventilation and air conditioning system for the ECN3 experimental area and the TCC8 and GHN300 service tunnels and for the dismantling of the existing system

    E-Print Network [OSTI]

    2014-01-01T23:59:59.000Z

    Proposal for the award of a contract for the design, supply, installation and commissioning of a ventilation and air conditioning system for the ECN3 experimental area and the TCC8 and GHN300 service tunnels and for the dismantling of the existing system

  4. Does Mixing Make Residential Ventilation More Effective?

    E-Print Network [OSTI]

    Sherman, Max

    2011-01-01T23:59:59.000Z

    Mechanical Ventilation Systems. ” Int. J. Ventilation, 6(4),Residential Mechanical Ventilation Systems. ” ASHRAE HVAC&Rfor Extension of Ventilation System Tracer Gas Testing. ”

  5. Performance of ventilators for noninvasive positive pressure ventilation in children

    E-Print Network [OSTI]

    Boyer, Edmond

    1 Performance of ventilators for noninvasive positive pressure ventilation in children Brigitte title: ventilators for noninvasive ventilation Supports and grants: The research of Brigitte Fauroux;2 Abstract The aim of the study was to evaluate the performance characteristics of all the ventilators

  6. A study of time-dependent responses of a mechanical displacement ventilation (DV) system and an underfloor air distribution (UFAD) system : building energy performance of the UFAD system

    E-Print Network [OSTI]

    Yu, Jong Keun

    2010-01-01T23:59:59.000Z

    climates, annual electricity consumption of UFAD is alwaysso the cooling electricity consumption has become importantsummers, the electricity consumption for air conditioning

  7. Premium Ventilation Package Testing Short-Term Monitoring Report Task 7

    E-Print Network [OSTI]

    Premium Ventilation Package Testing Short-Term Monitoring Report ­ Task 7 Review Draft Submittal. 00038702 RTU AirCarePlus & Premium Ventilation Program COTR - Jack Callahan (503) 230-4496 / jmcallahan Ventilation Package Testing PECI Short-Term Monitoring Report ­ Task 7 REVIEW DRAFT: 9/14/2009 2 Table

  8. Floor-Supply Displacement Ventilation in a Small Office Nobukazu Kobayashi

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    1 Floor-Supply Displacement Ventilation in a Small Office Nobukazu Kobayashi Building Technology Displacement ventilation . Computational fluid dynamics . Experimental measurements . Floor supply . Indoor air ventilation system using computational-fluid-dynamics (CFD). The experiment was carried out in a full

  9. A simplified approach to describe complex diffusers in displacement ventilation for CFD simulations

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    A simplified approach to describe complex diffusers in displacement ventilation for CFD simulations to improve indoor air quality while simultaneously reduce energy demand, displacement ventilation is becom ent ventilation usin g com putational fluid dynamics (CFD) is challenging due to the com plexity

  10. Midlevel Ventilation's Constraint on Tropical Cyclone Intensity BRIAN TANG AND KERRY EMANUEL

    E-Print Network [OSTI]

    Emanuel, Kerry A.

    Midlevel Ventilation's Constraint on Tropical Cyclone Intensity BRIAN TANG AND KERRY EMANUEL ventilation, or the flux of low-entropy air into the inner core of a tropical cyclone (TC), is a hy to assess how ventilation affects tropical cyclone intensity via two possible pathways: the first through

  11. Particle transport in low-energy ventilation systems. Part 1: theory of steady states

    E-Print Network [OSTI]

    Bolster, Diogo

    , such as that pro- vided by a conventional overhead heating, ventilating and air-conditioning system, is mixingParticle transport in low-energy ventilation systems. Part 1: theory of steady states Introduction of this energy is spent on ventilation of buildings with summer time cooling account for almost 10% of the US

  12. PIERS ONLINE, VOL. 5, NO. 7, 2009 637 Ventilation Efficiency and Carbon Dioxide (CO2) Concentration

    E-Print Network [OSTI]

    Halgamuge, Malka N.

    inadequate ventilation. The American Society of Heating,Refrigerating and Air Conditioning Engineers (ASHRAEPIERS ONLINE, VOL. 5, NO. 7, 2009 637 Ventilation Efficiency and Carbon Dioxide (CO2) Concentration is approximately 400 parts per million. In this study, we investigate the relationship between ventilation

  13. Natural Ventilation in Buildings: Measurement in a Wind Tunnel and Numerical Simulation with Large Eddy Simulation

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    save energy consumed by the heating, ventilating, and air- conditioning systems in a building1 Natural Ventilation in Buildings: Measurement in a Wind Tunnel and Numerical Simulation@purdue.edu Abstract Natural ventilation in buildings can create a comfortable and healthy indoor environment, and can

  14. Controllability and invariance of monotone systems for robust ventilation automation in buildings

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Controllability and invariance of monotone systems for robust ventilation automation in buildings [2] and control [3] of Heating, Ventilating and Air Conditioning (HVAC) systems leads to an improved comfort for the users and a reduction of energy consumption. Compared to traditional ceiling ventilation

  15. `Individual Ventilated Caging System' & `Animal Cage Changing Station' Page 1 NATIONAL INSTITUTE OF IMMUNOLOGY

    E-Print Network [OSTI]

    Bhalla, Upinder S.

    `Individual Ventilated Caging System' & `Animal Cage Changing Station' Page 1 NATIONAL INSTITUTE: (1) `Individual Ventilated Caging System' & (2) `Animal Cage Changing Station' Director, NII ­ New Document (Rs) 1 Individual Ventilated Caging System (Annexure-A) Air Handling Unit = 15 Nos. Animal

  16. DEMAND CONTROLLED VENTILATION AND CLASSROOM VENTILATION

    E-Print Network [OSTI]

    Fisk, William J.

    2014-01-01T23:59:59.000Z

    Refrigerating, and Air Conditioning Engineers, Inc. ---.Refrigerating and Air-Conditioning Engineers, Inc. ASTM.Refrigerating, and Air Conditioning Engineers, Inc. , 213-

  17. Demand Controlled Ventilation and Classroom Ventilation

    E-Print Network [OSTI]

    Fisk, William J.

    2014-01-01T23:59:59.000Z

    Refrigerating, and Air Conditioning Engineers, Inc. ---.Refrigerating and Air-Conditioning Engineers, Inc. ASTM.Refrigerating, and Air Conditioning Engineers, Inc. , 213-

  18. Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

    E-Print Network [OSTI]

    Sherman, Max H.

    2011-01-01T23:59:59.000Z

    Dynamic Control of Ventilation Systems M.H. Sherman and I.S.a defined mechanical ventilation system to provide minimumair as part of ventilation system operation changes with

  19. Key Factors in Displacement Ventilation Systems for Better IAQ

    E-Print Network [OSTI]

    Wang, X.; Chen, J.; Li, Y.; Wang, Z.

    2006-01-01T23:59:59.000Z

    This paper sets up a mathematical model of three-dimensional steady turbulence heat transfer in an air-conditioned room of multi-polluting heat sources. Numerical simulation helps identify key factors in displacement ventilation systems that affect...

  20. Ventilation Effectiveness Research at UT-Typer Lab Houses

    Broader source: Energy.gov (indexed) [DOE]

    Ventilation Effectiveness Research at UT-Tyler Lab Houses Source Of Outside Air, Distribution, Filtration Armin Rudd Twin (almost) Lab Houses at UT-Tyler House 2: Unvented attic,...

  1. Key Factors in Displacement Ventilation Systems for Better IAQ 

    E-Print Network [OSTI]

    Wang, X.; Chen, J.; Li, Y.; Wang, Z.

    2006-01-01T23:59:59.000Z

    This paper sets up a mathematical model of three-dimensional steady turbulence heat transfer in an air-conditioned room of multi-polluting heat sources. Numerical simulation helps identify key factors in displacement ventilation systems that affect...

  2. Natural ventilation possibilities for buildings in the United States

    E-Print Network [OSTI]

    Dean, Brian N. (Brian Nathan), 1974-

    2001-01-01T23:59:59.000Z

    In the United States, many of the commercial buildings built in the last few decades are completely mechanically air conditioned, without the capability to use natural ventilation. This habit has occurred in building designs ...

  3. Building Science- Ventilation

    Broader source: Energy.gov [DOE]

    This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question Ť"What are the best ventilation techniques"

  4. Ventilation for an enclosure of a gas turbine and related method

    DOE Patents [OSTI]

    Schroeder, Troy Joseph (Mauldin, SC); Leach, David (Simpsonville, SC); O'Toole, Michael Anthony (Greenfield Center, NY)

    2002-01-01T23:59:59.000Z

    A ventilation scheme for a rotary machine supported on pedestals within an enclosure having a roof, end walls and side walls with the machine arranged parallel to the side walls, includes ventilation air inlets located in a first end wall of the enclosure; a barrier wall located within the enclosure, proximate the first end wall to thereby create a plenum chamber. The barrier wall is constructed to provide a substantially annular gap between the barrier wall and a casing of the turbine to thereby direct ventilation air axially along the turbine; one or more ventilation air outlets located proximate a second, opposite end wall on the roof of the enclosure. In addition, one or more fans are provided for pulling ventilating air into said plenum chamber via the ventilation air inlets.

  5. Oxidation rate of K-Basin spent nuclear fuel in moist air

    SciTech Connect (OSTI)

    Abrefah, J.; Buchanan, H.C.; Marschman, S.C.

    1998-06-01T23:59:59.000Z

    Experiments have been conducted by Pacific Northwest National Laboratory to determine the oxidation rate of damaged/corroded N-Reactor fuel material in moist air. Five SNF pieces (with regular geometrical shapes) sectioned from a damaged element stored in the K-West Basin were oxidized in flowing air containing moisture. The SNF oxidation behavior in moist air at a temperature of 198 C can best be fitted by parabolic oxidation kinetics. A linear rate equation gave the best fit to the oxidation data at 250 C and above. The results within the temperature range studied, therefore, show a transition from parabolic oxidation kinetics to linear oxidation kinetics. The transition temperature is somewhere between 198 C and 250 C. The tests at approximately 300 C gave results that were very different from the other tests at temperatures of 198 C, 250 C, and 349 C. The SNF sample weight change at this temperature showed erratic behavior. Visual examination indicated the sample fragmented into small pieces and powder as a result of rapid oxidation and hydration. Additional tests at temperatures close to 300 C (i.e., 300 {+-} 10 C) are recommended in order to fully understand the oxidation behavior of the damaged/corroded SNF samples in moist air at about 300 C.

  6. Building America Case Study: Evaluation of Ventilation Strategies in New Construction Multifamily Buildings, New York, New York (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-09-01T23:59:59.000Z

    In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the 'fresh' air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the 'normal leakage paths through the building envelope' disappear. CARB researchers have found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. Product performance data are based on laboratory tests, and the assumption is that products will perform similarly in the field. Proper application involves matching expected performance at expected building pressures, but there is no guarantee that those conditions will exist consistently in the finished building. This research effort, which included several weeks of building pressure monitoring, sought to provide field validation of system performance. The performance of four substantially different strategies for providing make-up air to apartments was evaluated.

  7. Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

    E-Print Network [OSTI]

    Sherman, Max H.

    2011-01-01T23:59:59.000Z

    Rudd. 2007. Review of residential ventilation technologies.2009. EISG Final Report: Residential Integrated VentilationDesign and Operation of Residential Cooling Systems. Proc.

  8. A survey of air flow models for multizone structures

    SciTech Connect (OSTI)

    Feustel, H.E.; Dieris, J.

    1991-03-01T23:59:59.000Z

    Air flow models are used to simulate the rates of incoming and outgoing air flows for a building with known leakage under given weather and shielding conditions. Additional information about the flow paths and air-mass flows inside the building can only by using multizone air flow models. In order to obtain more information on multizone air flow models, a literature review was performed in 1984. A second literature review and a questionnaire survey performed in 1989, revealed the existence of 50 multizone air flow models, all developed since 1966, two of which are still under development. All these programs use similar flow equations for crack flow but differ in the versatility to describe the full range of flow phenomena and the algorithm provided for solving the set of nonlinear equations. This literature review was found that newer models are able to describe and simulate the ventilation systems and interrelation of mechanical and natural ventilation. 27 refs., 2 figs., 1 tab.

  9. Indoor Air Quality Assessment of the San Francisco Federal Building

    SciTech Connect (OSTI)

    Apte, Michael; Bennett, Deborah H.; Faulkner, David; Maddalena, Randy L.; Russell, Marion L.; Spears, Michael; Sullivan, Douglas P; Trout, Amber L.

    2008-07-01T23:59:59.000Z

    An assessment of the indoor air quality (IAQ) of the San Francisco Federal Building (SFFB) was conducted on May 12 and 14, 2009 at the request of the General Services Administration (GSA). The purpose of the assessment was for a general screening of IAQ parameters typically indicative of well functioning building systems. One naturally ventilated space and one mechanically ventilated space were studied. In both zones, the levels of indoor air contaminants, including CO2, CO, particulate matter, volatile organic compounds, and aldehydes, were low, relative to reference exposure levels and air quality standards for comparable office buildings. We found slightly elevated levels of volatile organic compounds (VOCs) including two compounds often found in"green" cleaning products. In addition, we found two industrial solvents at levels higher than typically seen in office buildings, but the levels were not sufficient to be of a health concern. The ventilation rates in the two study spaces were high by any standard. Ventilation rates in the building should be further investigated and adjusted to be in line with the building design. Based on our measurements, we conclude that the IAQ is satisfactory in the zone we tested, but IAQ may need to be re-checked after the ventilation rates have been lowered.

  10. Effect of Ventilation Strategies on

    E-Print Network [OSTI]

    1 Effect of Ventilation Strategies on Residential Ozone Levels Iain S. Walker ventilation used to reduce concentrations of indoor-generated pollutants. When assessing the effect of deliberate ventilation on occupant health one should consider not only

  11. Performance Assessment of Photovoltaic Attic Ventilator Fans

    Broader source: Energy.gov [DOE]

    A case study of photovoltaic attic ventilator fans was conducted on an occupied single family home in Central Florida. Two fans were installed at mid-summer in an instrumented home where attic air temperature, meteorological conditions and space cooling electric power were measured. The home already had an attic radiant barrier, but still experienced attic air temperatures in excess of 130oF.

  12. Chemical response of methane/air diffusion flames to unsteady strain rate

    SciTech Connect (OSTI)

    Im, H.G.; Chen, J.H. [Sandia National Labs., Livermore, CA (United States); Chen, J.Y. [Univ. of California, Berkeley, CA (United States). Dept. of Mechanical Engineering

    1998-03-01T23:59:59.000Z

    Effects of unsteady strain rate on the response of methane/air diffusion flames are studied. The authors use the finite-domain opposed flow configuration in which the nozzle exit velocity is imposed as a function of time. The GRI mechanism v2.11 is used for the detailed methane/air chemistry. The response of individual species to monochromatic oscillation in strain rate with various frequencies reveals that the fluctuation of slow species, such as CO and NO{sub x}, is more rapidly suppressed as the flow time scale decreases. It is also observed that the maximum CO concentration is very insensitive to the variation in the scalar dissipation rate. An extinction event due to an abrupt imposition of high strain rates is also simulated by an impulsive velocity with various frequencies. For a fast impulse, a substantial overshoot in NO{sub 2} concentration is observed after extinction. Finally, the overall fuel burning rate shows a nonmonotonic response to the variation in characteristic unsteady time scale, while the emission indices for NO{sub x} shows monotonic decay in response as frequency is increased.

  13. Using a Constant Volume Displacement Ventilation System to Create a Micro Climate in a Large Airport Terminal in Bangkok

    E-Print Network [OSTI]

    Simmonds, P.; Gaw, W.

    1996-01-01T23:59:59.000Z

    Using a Constant Volume Displacement Ventilation System to Create a Micro Climate in a Large Airport Terminal in Bangkok Peter Simmonds Flack + Kurtz New York Abstract In order to conserve energy and create a comfortable climate for both.... CF'D analysis was used to investigate the effectiveness of a displacement ventilation system. A displacement ventilation system pours ventilation air into a space across the floor. The temperature difference between the supply air and the room...

  14. Experiments measuring particle deposition from fully developed turbulent flow in ventilation ducts

    SciTech Connect (OSTI)

    Sippola, Mark R.; Nazaroff, William W.

    2003-08-01T23:59:59.000Z

    Particle deposition in ventilation ducts influences particle exposures of building occupants and may lead to a variety of indoor air quality concerns. Experiments have been performed in a laboratory to study the effects of particle size and air speed on deposition rates of particles from turbulent air flows in galvanized steel and internally insulated ducts with hydraulic diameters of 15.2 cm. The duct systems were constructed of materials typically found in commercial heating, ventilating and air conditioning (HVAC) systems. In the steel duct system, experiments with nominal particle sizes of 1, 3, 5, 9 and 16 {micro}m were conducted at each of three nominal air speeds: 2.2, 5.3 and 9.0 m/s. In the insulated duct system, deposition rates of particles with nominal sizes of 1, 3, 5, 8 and 13 {micro}m were measured at nominal air speeds of 2.2, 5.3 and 8.8 m/s. Fluorescent techniques were used to directly measure the deposition velocities of monodisperse fluorescent particles to duct surfaces (floor, wall and ceiling) at two straight duct sections where the turbulent flow profile was fully developed. In steel ducts, deposition rates were higher to the duct floor than to the wall, which were, in turn, greater than to the ceiling. In insulated ducts, deposition was nearly the same to the duct floor, wall and ceiling for a given particle size and air speed. Deposition to duct walls and ceilings was greatly enhanced in insulated ducts compared to steel ducts. Deposition velocities to each of the three duct surface orientations in both systems were found to increase with increasing particle size or air velocity over the ranges studied. Deposition rates measured in the current experiments were in general agreement with the limited observations of similar systems by previous researchers.

  15. Ventilation Behavior and Household Characteristics in New California Houses

    E-Print Network [OSTI]

    Price, Phillip N.; Sherman, Max H.

    2006-01-01T23:59:59.000Z

    pollutant sources get more ventilation. • Except householdshealth issues motivate ventilation behavior. • Security andQuality, IAQ, mechanical ventilation systems, ventilation

  16. Field study of exhaust fans for mitigating indoor air quality problems: Final report

    SciTech Connect (OSTI)

    Grimsrud, D.T.; Szydlowski, R.F.; Turk, B.H.

    1986-09-01T23:59:59.000Z

    Residential ventilation in the United States housing stock is provided primarily by infiltration, the natural leakage of outdoor air into a building through cracks and holes in the building shell. Since ventilation is the dominant mechanism for control of indoor pollutant concentrations, low infiltration rates caused fluctuation in weather conditions may lead to high indoor pollutant concentrations. Supplemental mechanical ventilation can be used to eliminate these periods of low infiltration. This study examined effects of small continuously-operating exhaust fan on pollutant concentrations and energy use in residences.

  17. Lau, J. and Chen, Q. 2007. "Floor-supply displacement ventilation for workshops," Building and Environment, 42(4), 1718-1730.

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    of the heating, ventilating and air-conditioning (HVAC) systems used in U.S. buildings are mixing ventilation1 Lau, J. and Chen, Q. 2007. "Floor-supply displacement ventilation for workshops," Building and Environment, 42(4), 1718-1730. FLOOR-SUPPLY DISPLACEMENT VENTILATION FOR WORKSHOPS Josephine Lau and Qingyan

  18. Automatic Verification of Wireless Control in a Mining Ventilation Maria D. Di Benedetto1, Alessandro D'Innocenzo1, Emmanuele Serra1, Emmanuel Witrant2

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Automatic Verification of Wireless Control in a Mining Ventilation System Maria D. Di Benedetto1 control problem for a mine ventilation system. Ventilation control is essential for the control for the so called secondary ventilation system that ensures air flow in the chambers of the mine where

  19. Assessment of organic compound exposures, thermal comfort parameters, and HVAC system-driven air exchange rates in public school portable classrooms in California

    E-Print Network [OSTI]

    Shendell, Derek Garth

    2010-01-01T23:59:59.000Z

    reported one or more ventilation problems, and the variousfraction experience ventilation and IAQ problems, and healthoff. Thus, the problem of inadequate ventilation appeared to

  20. Impacts of Mixing on Acceptable Indoor Air Quality in Homes

    SciTech Connect (OSTI)

    Sherman, Max H.; Walker, Iain I.

    2010-01-01T23:59:59.000Z

    Ventilation reduces occupant exposure to indoor contaminants by diluting or removing them. In a multi-zone environment such as a house, every zone will have different dilution rates and contaminant source strengths. The total ventilation rate is the most important factor in determining occupant exposure to given contaminant sources, but the zone-specific distribution of exhaust and supply air and the mixing of ventilation air can play significant roles. Different types of ventilation systems will provide different amounts of mixing depending on several factors such as air leakage, air distribution system, and contaminant source and occupant locations. Most U.S. and Canadian homes have central heating, ventilation, and air conditioning systems, which tend to mix the air; thus, the indoor air in different zones tends to be well mixed for significant fractions of the year. This article reports recent results of investigations to determine the impact of air mixing on exposures of residential occupants to prototypical contaminants of concern. We summarize existing literature and extend past analyses to determine the parameters than affect air mixing as well as the impacts of mixing on occupant exposure, and to draw conclusions that are relevant for standards development and for practitioners designing and installing home ventilation systems. The primary conclusion is that mixing will not substantially affect the mean indoor air quality across a broad population of occupants, homes, and ventilation systems, but it can reduce the number of occupants who are exposed to extreme pollutant levels. If the policy objective is to minimize the number of people exposed above a given pollutant threshold, some amount of mixing will be of net benefit even though it does not benefit average exposure. If the policy is to minimize exposure on average, then mixing air in homes is detrimental and should not be encouraged. We also conclude that most homes in the US have adequate mixing already, but that new, high-performance homes may require additional mixing. Also our results suggest that some differentiation should be made in policies and standards for systems that provide continuous exhaust, thereby reducing relative dose for occupants overall.

  1. Recommended Changes to Specifications for Demand Controlled Ventilation in California's Title 24 Building Energy Efficiency Standards

    SciTech Connect (OSTI)

    Fisk, William J.; Sullivan, Douglas P.; Faulkner, David

    2010-04-08T23:59:59.000Z

    In demand-controlled ventilation (DCV), rates of outdoor air ventilation are automatically modulated as occupant density varies. The objective is to keep ventilation rates at or above design specifications and code requirements and also to save energy by avoiding excessive ventilation rates. DCV is most often used in spaces with highly variable and sometime dense occupancy. In almost all cases, carbon dioxide (CO{sub 2}) sensors installed in buildings provide the signal to the ventilation rate control system. People produce and exhale CO{sub 2} as a consequence of their normal metabolic processes; thus, the concentrations of CO{sub 2} inside occupied buildings are higher than the concentrations of CO{sub 2} in the outdoor air. The magnitude of the indoor-outdoor CO{sub 2} concentration difference decreases as the building's ventilation rate per person increases. The difference between the indoor and outdoor CO{sub 2} concentration is also a proxy for the indoor concentrations of other occupant-generated bioeffluents, such as body odors. Reviews of the research literature on DCV indicate a significant potential for energy savings, particularly in buildings or spaces with a high and variable occupancy. Based on modeling, cooling energy savings from applications of DCV are as high as 20%. With support from the California Energy Commission and the U.S. Department of Energy, the Lawrence Berkeley National Laboratory has performed research on the performance of CO{sub 2} sensing technologies and optical people counters for DCV. In addition, modeling was performed to evaluate the potential energy savings and cost effectiveness of using DCV in general office spaces within the range of California climates. The above-described research has implications for the specifications pertaining to DCV in section 121 of the California Title 24 Standard. Consequently, this document suggests possible changes in these specifications based on the research findings. The suggested changes in specifications were developed in consultation with staff from the Iowa Energy Center who evaluated the accuracy of new CO{sub 2} sensors in laboratory-based research. In addition, staff of the California Energy Commission, and their consultants in the area of DCV, provided input for the suggested changes in specifications.

  2. Impacts of Mixing on Acceptable Indoor Air Quality in Homes

    E-Print Network [OSTI]

    Sherman, Max H.

    2010-01-01T23:59:59.000Z

    local mean ages of air in buildings for characterizing ventilationof local exhaust increases average whole-house ventilation

  3. Integrated Demand Controlled Ventilation for Single Duct VAV System with Conference Rooms

    E-Print Network [OSTI]

    Yu, Y.; Liu, M.; Cho, Y.; Xu, K.

    2007-01-01T23:59:59.000Z

    Single duct variable air volume (VAV) systems are widely used in office buildings to achieve energy savings. It supplies proper amount of conditioned air to satisfy both the load and the ventilation requirements of each individual zone. To obtain...

  4. Effects of air oxidation on the dissolution rate of LWR spent fuel

    SciTech Connect (OSTI)

    Gray, W.J.; Thomas, L.E.; Einziger, R.E.

    1992-11-01T23:59:59.000Z

    Dissolution rates for air-oxidized spent fuel were measured in flowthrough tests. Results from two types of specimens, separated grains and multigrain particles, both in oxidized (U[sub 4]O[sub 9+x]) and unoxidized (UO[sub 2]) conditions indicated only minor effects of oxidation on the surface-area-normalized rates. Similar results were obtained for unirradiated specimens in three different oxidation states (UO[sub 2], U[sub 3]O[sub 7], and U[sub 3]O[sub 8]). These observations have important practical implications for disposal of spent fuel in a geologic repository as well as implications regarding the oxidative dissolution mechanism of UO[sub 2] fuel.

  5. Measure Guideline: Selecting Ventilation Systems for Existing Homes

    SciTech Connect (OSTI)

    Aldrich, R.

    2014-02-01T23:59:59.000Z

    This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

  6. Mixed-Mode Ventilation and Building Retrofits

    E-Print Network [OSTI]

    Brager, Gail; Ackerly, Katie

    2010-01-01T23:59:59.000Z

    Page 15 Mixed-Mode Ventilation and Building RetrofitsEngineers. 2000. Mixed-mode ventilation. CIBSE ApplicationsMichael. 2000. Hybrid Ventilation Systems: An Arup Approach

  7. Design methods for displacement ventilation: Critical review.

    E-Print Network [OSTI]

    Schiavon, Stefano

    2006-01-01T23:59:59.000Z

    Displacement ventilation in non-industrial premises, REHVADisplacement ventilation in non-industrial premises, REHVAof displacement ventilation in non-industrial premises. The

  8. Infiltration in ASHRAE's Residential Ventilation Standards

    E-Print Network [OSTI]

    Sherman, Max

    2008-01-01T23:59:59.000Z

    often need mechanical ventilation systems to meet current about mechanical ventilation systems but has a default unbalanced mechanical ventilation systems change  the 

  9. Design of an Overmoded-Waveguide Directional Antenna for Use in In-Building Ventilation Duct Wireless Networks

    E-Print Network [OSTI]

    Stancil, Daniel D.

    -to-design wireless net- works with better coverage is to use heating, ventilation, and air conditioning (HVAC) ductsDesign of an Overmoded-Waveguide Directional Antenna for Use in In-Building Ventilation Duct ventilation ducts. We obtain experimentally the element size and spacing of a reflector and driven element

  10. This booklet has been developed to serve as an aid in selecting a laboratory fume hood ventilation system.

    E-Print Network [OSTI]

    Farritor, Shane

    as an aid in selecting a laboratory fume hood ventilation system. The information is intended to be unbiased consider the whole picture -- the laboratory space, the building's ventilation system, the hood's location Ventilation System Components and Accessories Remote Blowers 13 Blower Sizing 14 Air Volume 14 Static Pressure

  11. A New Empirical Model for Predicting Single-Sided, Wind-Driven Natural Ventilation in Buildings

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    A New Empirical Model for Predicting Single-Sided, Wind-Driven Natural Ventilation in Buildings-sided natural ventilation is difficult due to the bi-directional flow at the opening and the complex flow around buildings. A new empirical model was developed that can predict the mean ventilation rate and fluctuating

  12. Field Study of Exhaust Fans for Mitigating Indoor Air Quality Problems: Final Report to Bonneville Power Administration

    E-Print Network [OSTI]

    Grimsrud, David T.

    2009-01-01T23:59:59.000Z

    solution to ventilation problem in some situations [TurielIndoor Air Quality Problem. - BPA Ventilation - Air Qualityventilation on indoor air Quality and to develop energy conserving strategies to mitigate potential problems

  13. Recovering Energy From Ventilation and Process Airstreams

    E-Print Network [OSTI]

    Cheney, W. A.

    RECOVERING ENERGY FROM VENTILATION AND PROCESS AIRSTREAMS Heat Exchangers and contaminant Recovery William A. Cheney united Air Specialists, Inc. Cincinnati, Ohio The high cost of energy has prompted industry to look for new ways to reduce... 17-19, 1986 CONTAMINANT RECOVERY The ability to capture waste energy from an airstream, while simultaneously condensing hydrocarbon vapors, is a rela tively new technique in the heat-recovery market. In this process, high concentra tions...

  14. Ventilation Behavior and Household Characteristics in NewCalifornia Houses

    SciTech Connect (OSTI)

    Price, Phillip N.; Sherman, Max H.

    2006-02-01T23:59:59.000Z

    A survey was conducted to determine occupant use of windows and mechanical ventilation devices; barriers that inhibit their use; satisfaction with indoor air quality (IAQ); and the relationship between these factors. A questionnaire was mailed to a stratified random sample of 4,972 single-family detached homes built in 2003, and 1,448 responses were received. A convenience sample of 230 houses known to have mechanical ventilation systems resulted in another 67 completed interviews. Some results are: (1) Many houses are under-ventilated: depending on season, only 10-50% of houses meet the standard recommendation of 0.35 air changes per hour. (2) Local exhaust fans are under-utilized. For instance, about 30% of households rarely or never use their bathroom fan. (3) More than 95% of households report that indoor air quality is ''very'' or ''somewhat'' acceptable, although about 1/3 of households also report dustiness, dry air, or stagnant or humid air. (4) Except households where people cook several hours per week, there is no evidence that households with significant indoor pollutant sources get more ventilation. (5) Except households containing asthmatics, there is no evidence that health issues motivate ventilation behavior. (6) Security and energy saving are the two main reasons people close windows or keep them closed.

  15. Indoor Air Quality in 24 California Residences Designed as High Performance Green Homes

    E-Print Network [OSTI]

    Less, Brennan

    2012-01-01T23:59:59.000Z

    Gas furnace Air-to-air heat pump Gas fireplace (primarywith their air-to-air heat pumps, such as nighttimeSystem Type None Air-to-air heat pump Night ventilative

  16. Ventilation technologies scoping study

    SciTech Connect (OSTI)

    Walker, Iain S.; Sherman, Max H.

    2003-09-30T23:59:59.000Z

    This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the needs of California, determining residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and level of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  17. The effects of strain rate and curvature on surface density function transport in turbulent premixed methane-air and hydrogen-air flames: A comparative study

    SciTech Connect (OSTI)

    Chakraborty, N. [Engineering Department, University of Liverpool, Brownlow Hill, Liverpool L69 3GH (United Kingdom); Hawkes, E.R. [School of Photovoltaic and Renewable Energy Engineering, University of New South Wales, Sydney, NSW 2052 (Australia); Chen, J.H. [Combustion Research Facility, Sandia National Laboratories, Livermore, CA 94551 (United States); Cant, R.S. [Engineering Department, Cambridge University, Trumpington Street, Cambridge CB2 1PZ (United Kingdom)

    2008-07-15T23:59:59.000Z

    The effects of tangential strain rate and curvature on the surface density function (SDF) and on source terms within the SDF transport equation are studied for lean methane-air and hydrogen-air flames using two-dimensional direct numerical simulations with detailed chemistry. A positive correlation is observed between the SDF and the tangential strain rate, and this is explained in terms of the interaction between the local tangential strain rate and the dilatation rate due to heat release. Curvature is also seen to affect the SDF through the curvature response of both tangential strain rate and dilatation rate on a given flame isosurface. Strain rate and curvature are found to have an appreciable effect on several terms of the SDF transport equation. The SDF straining term in both methane and hydrogen flames is correlated positively with tangential strain rate, as expected, and is also correlated negatively with curvature. For methane flames, the SDF propagation term is found to correlate negatively with flame curvature toward the reactant side of the flame and positively toward the product side. By contrast, for hydrogen flames the SDF propagation term is negatively correlated with curvature throughout the flame brush. The variation of the SDF curvature term with local flame curvature for both methane and hydrogen flames is found to be nonlinear due to the additional stretch induced by the tangential diffusion component of the displacement speed. Physical explanations are provided for all of these effects, and the modeling implications are considered in detail. (author)

  18. Variation in rectal temperature, respiratory rate, and pulse rate of cattle as related to variations in solar radiation, air temperature, wind velocity, and vapor pressure

    E-Print Network [OSTI]

    Quazi, Mohammad Fazlur Rahim

    1955-01-01T23:59:59.000Z

    VARIATION IN RECTAL TEMPERATURE, RESPIRATORY RATE, AND PULSE RATE GF CATTLE AS RELATED TO VARIATIONS IN SOLAR RADIATION, AIR TEMPERATURE, WIND VELOCITY, AND VAPOR PRESSURE A Dissertation By Mohammad Fazlur Rahim Quazi Approved as to style... Dissertation By Mohammad Fazlur Rahim tyiazi Submitted to the Graduate School of the Agricultural and Mechanical College of Texas in partial fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY May 1955 Major Subject: Genetics ? ?4...

  19. Innovative Energy Efficient Industrial Ventilation

    E-Print Network [OSTI]

    Litomisky, A.

    2005-01-01T23:59:59.000Z

    factories, we found striking dichotomy between the classical “static” design of ventilation systems and constantly changing workflow and business demands. Using data from real factories, we are able to prove that classical industrial ventilation design...

  20. Modeling particle loss in ventilation ducts

    SciTech Connect (OSTI)

    Sippola, Mark R.; Nazaroff, William W.

    2003-04-01T23:59:59.000Z

    Empirical equations were developed and applied to predict losses of 0.01-100 {micro}m airborne particles making a single pass through 120 different ventilation duct runs typical of those found in mid-sized office buildings. For all duct runs, losses were negligible for submicron particles and nearly complete for particles larger than 50 {micro}m. The 50th percentile cut-point diameters were 15 {micro}m in supply runs and 25 {micro}m in return runs. Losses in supply duct runs were higher than in return duct runs, mostly because internal insulation was present in portions of supply duct runs, but absent from return duct runs. Single-pass equations for particle loss in duct runs were combined with models for predicting ventilation system filtration efficiency and particle deposition to indoor surfaces to evaluate the fates of particles of indoor and outdoor origin in an archetypal mechanically ventilated building. Results suggest that duct losses are a minor influence for determining indoor concentrations for most particle sizes. Losses in ducts were of a comparable magnitude to indoor surface losses for most particle sizes. For outdoor air drawn into an unfiltered ventilation system, most particles smaller than 1 {micro}m are exhausted from the building. Large particles deposit within the building, mostly in supply ducts or on indoor surfaces. When filters are present, most particles are either filtered or exhausted. The fates of particles generated indoors follow similar trends as outdoor particles drawn into the building.

  1. AIR SEALING Seal air leaks and save energy!

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    AIR SEALING Seal air leaks and save energy! W H A T I S A I R L E A K A G E ? Ventilation is fresh air that enters a house in a controlled manner to exhaust excess moisture and reduce odors and stuffiness. Air leakage, or infiltration, is outside air that enters a house uncontrollably through cracks

  2. CO2 MONITORING FOR DEMAND CONTROLLED VENTILATION IN COMMERCIAL BUILDINGS

    SciTech Connect (OSTI)

    Fisk, William J.; Sullivan, Douglas P.; Faulkner, David; Eliseeva, Ekaterina

    2010-03-17T23:59:59.000Z

    Carbon dioxide (CO{sub 2}) sensors are often deployed in commercial buildings to obtain CO{sub 2} data that are used, in a process called demand-controlled ventilation, to automatically modulate rates of outdoor air ventilation. The objective is to keep ventilation rates at or above design specifications and code requirements and also to save energy by avoiding excessive ventilation rates. Demand controlled ventilation is most often used in spaces with highly variable and sometime dense occupancy. Reasonably accurate CO{sub 2} measurements are needed for successful demand controlled ventilation; however, prior research has suggested substantial measurement errors. Accordingly, this study evaluated: (a) the accuracy of 208 CO{sub 2} single-location sensors located in 34 commercial buildings, (b) the accuracy of four multi-location CO{sub 2} measurement systems that utilize tubing, valves, and pumps to measure at multiple locations with single CO{sub 2} sensors, and (c) the spatial variability of CO{sub 2} concentrations within meeting rooms. The field studies of the accuracy of single-location CO{sub 2} sensors included multi-concentration calibration checks of 90 sensors in which sensor accuracy was checked at multiple CO{sub 2} concentrations using primary standard calibration gases. From these evaluations, average errors were small, -26 ppm and -9 ppm at 760 and 1010 ppm, respectively; however, the averages of the absolute values of error were 118 ppm (16%) and 138 ppm (14%), at concentrations of 760 and 1010 ppm, respectively. The calibration data are generally well fit by a straight line as indicated by high values of R{sup 2}. The Title 24 standard specifies that sensor error must be certified as no greater than 75 ppm for a period of five years after sensor installation. At 1010 ppm, 40% of sensors had errors greater than {+-}75 ppm and 31% of sensors has errors greater than {+-}100 ppm. At 760 ppm, 47% of sensors had errors greater than {+-}75 ppm and 37% of sensors had errors greater than {+-}100 ppm. A significant fraction of sensors had errors substantially larger than 100 ppm. For example, at 1010 ppm, 19% of sensors had an error greater than 200 ppm and 13% of sensors had errors greater than 300 ppm. The field studies also included single-concentration calibration checks of 118 sensors at the concentrations encountered in the buildings, which were normally less than 500 ppm during the testing. For analyses, these data were combined with data from the calibration challenges at 510 ppm obtained during the multi-concentration calibration checks. For the resulting data set, the average error was 60 ppm and the average of the absolute value of error was 154 ppm. Statistical analyses indicated that there were statistically significant differences between the average accuracies of sensors from different manufacturers. Sensors with a 'single lamp single wavelength' design tended to have a statistically significantly smaller average error than sensors with other designs except for 'single lamp dual wavelength' sensors, which did not have a statistically significantly lower accuracy. Sensor age was not consistently a statistically significant predictor of error.

  3. 3, 805826, 2006 Ventilation under

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    OSD 3, 805­826, 2006 Ventilation under global warming A. Gnanadesikan et al. Title Page Abstract ocean ventilation change under global warming? A. Gnanadesikan 1 , J. L. Russell 2 , and F. Zeng 3 1­826, 2006 Ventilation under global warming A. Gnanadesikan et al. Title Page Abstract Introduction

  4. Measure Guideline: Ventilation Cooling

    SciTech Connect (OSTI)

    Springer, D.; Dakin, B.; German, A.

    2012-04-01T23:59:59.000Z

    The purpose of this measure guideline on ventilation cooling is to provide information on a cost-effective solution for reducing cooling system energy and demand in homes located in hot-dry and cold-dry climates. This guideline provides a prescriptive approach that outlines qualification criteria, selection considerations, and design and installation procedures.

  5. Assessment of Indoor Air Quality Benefits and Energy Costs of

    E-Print Network [OSTI]

    Assessment of Indoor Air Quality Benefits and Energy Costs of Mechanical Ventilation J.M.Logue1,P Quality Benefits and Energy Costs of Mechanical Ventilation LBNL-4945E Disclaimer This document.H. Sherman, B.C. Singer, Assessment of Indoor Air Quality Benefits and Energy Costs of Mechanical Ventilation

  6. Building ventilation : a pressure airflow model computer generation and elements of

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Building ventilation : a pressure airflow model computer generation and elements of validation H when heating a residential building, approximately 30% of the energy loss is due to air renewal[1. Thus in tropical climates, natural ventilation affects essentially the inside comfort by favouring

  7. Ventilation | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative JC3 RSS SeptemberRenewable Energy,Geothermal3: RedAbout(Brochure),Ventilation

  8. Ventilation Behavior and Household Characteristics in New California Houses

    E-Print Network [OSTI]

    Price, Phillip N.; Sherman, Max H.

    2006-01-01T23:59:59.000Z

    IAQ, mechanical ventilation systems, ventilation standards,to have mechanical ventilation systems resulted in anotherhave and use mechanical ventilation systems; and what is the

  9. Equivalence in Ventilation and Indoor Air Quality

    E-Print Network [OSTI]

    Sherman, Max

    2012-01-01T23:59:59.000Z

    environment: PM 2.5 , acrolein, and formaldehyde. There isAcetaldehyde  Acrolein  Benzene  Formaldehyde  Naphthalene that total are PM 2.5 , acrolein, formaldehyde, and ozone.

  10. Heating, Ventilation and Air Conditioning Efficiency

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy ChinaofSchaefer To:Department of Energy CompletingPresented By: WALTER E. JOHNSTON, PE

  11. Heating, Ventilation and Air Conditioning Efficiency

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking of Blythe Solar Power ProjectHawai'iPresented By: WALTER E. JOHNSTON, PE

  12. Reference dosimetry at the Australian Synchrotron's imaging and medical beamline using free-air ionization chamber measurements and theoretical predictions of air kerma rate and half value layer

    SciTech Connect (OSTI)

    Crosbie, Jeffrey C.; Rogers, Peter A. W. [Department of Obstetrics and Gynaecology, University of Melbourne, The Royal Women's Hospital, Parkville, Victoria 3052 (Australia); Stevenson, Andrew W. [CSIRO Materials Science and Engineering, Clayton, Victoria 3169 (Australia); Hall, Christopher J. [Imaging and Medical Beamline, Australian Synchrotron, Clayton, Victoria 3168 (Australia); Lye, Jessica E. [Australian Radiation Protection and Nuclear Safety Agency, Yallambie, Victoria 3085 (Australia); Nordstroem, Terese [KTH Royal Institute of Technology, Stockholm SE-100 44 (Sweden); Midgley, Stewart M. [School of Physics, Monash University, Clayton, Victoria 3800 (Australia); Lewis, Robert A. [Department of Medical Imaging and Radiation Sciences, Monash University, Clayton, Victoria 3800 (Australia)

    2013-06-15T23:59:59.000Z

    Purpose: Novel, preclinical radiotherapy modalities are being developed at synchrotrons around the world, most notably stereotactic synchrotron radiation therapy and microbeam radiotherapy at the European Synchrotron Radiation Facility in Grenoble, France. The imaging and medical beamline (IMBL) at the Australian Synchrotron has recently become available for preclinical radiotherapy and imaging research with clinical trials, a distinct possibility in the coming years. The aim of this present study was to accurately characterize the synchrotron-generated x-ray beam for the purposes of air kerma-based absolute dosimetry. Methods: The authors used a theoretical model of the energy spectrum from the wiggler source and validated this model by comparing the transmission through copper absorbers (0.1-3.0 mm) against real measurements conducted at the beamline. The authors used a low energy free air ionization chamber (LEFAC) from the Australian Radiation Protection and Nuclear Safety Agency and a commercially available free air chamber (ADC-105) for the measurements. The dimensions of these two chambers are different from one another requiring careful consideration of correction factors. Results: Measured and calculated half value layer (HVL) and air kerma rates differed by less than 3% for the LEFAC when the ion chamber readings were corrected for electron energy loss and ion recombination. The agreement between measured and predicted air kerma rates was less satisfactory for the ADC-105 chamber, however. The LEFAC and ADC measurements produced a first half value layer of 0.405 {+-} 0.015 and 0.412 {+-} 0.016 mm Cu, respectively, compared to the theoretical prediction of 0.427 {+-} 0.012 mm Cu. The theoretical model based upon a spectrum calculator derived a mean beam energy of 61.4 keV with a first half value layer of approximately 30 mm in water. Conclusions: The authors showed in this study their ability to verify the predicted air kerma rate and x-ray attenuation curve on the IMBL using a simple experimental method, namely, HVL measurements. The HVL measurements strongly supports the x-ray beam spectrum, which in turn has a profound effect on x-ray dosimetry.

  13. Final Report Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores in California: predicted indoor air quality and energy consumption using a matrix of ventilation scenarios

    E-Print Network [OSTI]

    Apte, Michael G.

    2013-01-01T23:59:59.000Z

    MG. (2010). Balancing energy conservation and occupant needsReport   Balancing energy conservation and occupant needs Report Balancing energy conservation and occupant needs in

  14. Final Report Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores in California: predicted indoor air quality and energy consumption using a matrix of ventilation scenarios

    E-Print Network [OSTI]

    Apte, Michael G.

    2013-01-01T23:59:59.000Z

    20Climate%20Zones. Emmerich, S.J. , T. McDowell. (2005). “and the United States (Emmerich and McDowell, 2005; ASHRAE,motion. As described by Emmerich and McDowell (2005), “The

  15. Lightweight ventilated facade prototype: acoustic performance evaluation when the ventilation surface of

    E-Print Network [OSTI]

    Boyer, Edmond

    Lightweight ventilated facade prototype: acoustic performance evaluation when the ventilation Conference 23-27 April 2012, Nantes, France 3801 #12;1. INTRODUCTION Lightweight ventilated facades cavity is almost totally open, fully ventilated and not very wide. Therefore, its contribution

  16. Air distribution effectiveness with stratified air distribution systems

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    1 Air distribution effectiveness with stratified air distribution systems Kisup Lee* Zheng Jiang, Ph.D Qingyan Chen, Ph.D. Student Member ASHRAE Fellow ASHRAE ABSTRACT Stratified air distribution systems such as Traditional Displacement Ventilation (TDV) and Under- Floor Air Distribution (UFAD

  17. Particulate Air Pollution, Ambulatory Heart Rate Variability, and Cardiac Arrhythmia in Retirement Community Residents with Coronary Artery Disease

    E-Print Network [OSTI]

    Bartell, Scott M.; Longhurst, John; Tjoa, Thomas; Sioutas, Constantinos; Delfino, Ralph J.

    2013-01-01T23:59:59.000Z

    in association with air pollution and air temperature amongvariability with traffic and air pollution in patients withParticulate matter air pollution and cardiovascular disease:

  18. Particulate Air Pollution, Ambulatory Heart Rate Variability, and Cardiac Arrhythmia in Retirement Community Residents with Coronary Artery Disease

    E-Print Network [OSTI]

    Bartell, Scott M.; Longhurst, John; Tjoa, Thomas; Sioutas, Constantinos; Delfino, Ralph J.

    2013-01-01T23:59:59.000Z

    in association with air pollution and air temperature amongvariability with traffic and air pollution in patients withMS, Dockery DW. 2010. Air pollution and the triggering of

  19. Particulate air pollution, ambulatory heart rate variability, and cardiac arrhythmia in retirement community residents with coronary artery disease.

    E-Print Network [OSTI]

    Bartell, Scott M; Longhurst, John; Tjoa, Thomas; Sioutas, Constantinos; Delfino, Ralph J

    2013-01-01T23:59:59.000Z

    in association with air pollution and air temperature amongvariability with traffic and air pollution in patients withParticulate matter air pollution and cardiovascular disease:

  20. Noninvasive Positive Pressure Ventilation in the Emergency

    E-Print Network [OSTI]

    Noninvasive Positive Pressure Ventilation in the Emergency Department Mei-Ean Yeow, MDa , Jairo I, 1411 East 31st Street, Oakland, CA 94602-1018, USA Noninvasive ventilation is defined as the provision ventilators consist of both negative and positive pressure ventilators. Because negative pressure ventilation

  1. Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences

    SciTech Connect (OSTI)

    Hoeschele, M.A.; D.A. Springer

    2008-06-18T23:59:59.000Z

    The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the reheat coil adds additional heat to maintain the supply air temperature close to the return air temperature (100% latent cooling). Project Outcomes Key Phase II objectives were to develop a pre-production version of the system and to demonstrate its performance in an actual house. The system was first tested in the laboratory and subsequently underwent field-testing at a new house in Gainesville, Florida. Field testing began in 2006 with monitoring of a 'conventional best practices' system that included a two stage air conditioner and Energy Star dehumidifier. In September 2007, the I-HVCD components were installed for testing. Both systems maintained uniform indoor temperatures, but indoor RH control was considerably better with the I-HVCD system. The daily variation from average indoor humidity conditions was less than 2% for the I-HVCD vs. 5-7% for the base case system. Data showed that the energy use of the two systems was comparable. Preliminary installed cost estimates suggest that production costs for the current I-HVCD integrated design would likely be lower than for competing systems that include a high efficiency air conditioner, dehumidifier, and fresh air ventilation system. Project Benefits This project verified that the I-HVCD refrigeration compacts are compact (for easy installation and retrofit) and can be installed with air conditioning equipment from a variety of manufacturers. Project results confirmed that the system can provide precise indoor temperature and RH control under a variety of climate conditions. The I-HVCD integrated approach offers numerous benefits including integrated control, easier installation, and reduced equipment maintenance needs. Work completed under this project represents a significant step towards product commercialization. Improved indoor RH control and fresh air ventilation are system attributes that will become increasingly important in the years ahead as building envelopes improve and sensible cooling loads continue to fall. Technologies like I-HVCD will be instrumental in meeting goals set by Building America

  2. Estimating changes in ocean ventilation from early 1990s CFC-12 and late 2000s SF6 measurements

    E-Print Network [OSTI]

    Waugh, Darryn W.

    Estimating changes in ocean ventilation from early 1990s CFC-12 and late 2000s SF6 measurements constrain the rates and pathways of ocean ventilation and act as proxies for biogeochemically relevant gases such as CO2 and oxygen. Various techniques have deduced changes in ocean ventilation over decadal timescales

  3. Particle deposition in ventilation ducts: Connectors, bends anddeveloping flow

    SciTech Connect (OSTI)

    Sippola, Mark R.; Nazaroff, William W.

    2004-03-01T23:59:59.000Z

    In ventilation duct flow the turbulent flow profile is commonly disturbed or not fully developed and these conditions are likely to influence particle deposition to duct surfaces. Particle deposition rates at eight S-connectors, in two 90{sup o} duct bends and in two ducts where the turbulent flow profile was not fully developed were measured in a laboratory duct system with both galvanized steel and internally insulated ducts with hydraulic diameters of 15.2 cm. In the steel duct system, experiments with nominal particle diameters of 1, 3, 5, 9 and 16 {micro}m were conducted at each of three nominal air speeds: 2.2, 5.3 and 9.0 m/s. In the insulated duct system, deposition of particles with nominal diameters of 1, 3, 5, 8 and 13 {micro}m was measured at nominal air speeds of 2.2, 5.3 and 8.8 m/s. Fluorescent techniques were used to directly measure the deposition velocities of monodisperse fluorescent particles to duct surfaces. Deposition at S-connectors, in bends and in straight ducts with developing turbulence was often greater than deposition in straight ducts with fully developed turbulence for equal particle sizes, air speeds and duct surface orientations. Deposition rates at all locations were found to increase with an increase in particle size or air speed. High deposition rates at S-connectors resulted from impaction and these rates were nearly independent of the orientation of the S-connector. Deposition rates in the two 90{sup o} bends differed by more than an order of magnitude in some cases, probably because of the difference in turbulence conditions at the bend inlets. In straight steel ducts where the turbulent flow profile was developing, the deposition enhancement relative to fully developed turbulence generally increased with air speed and decreased with downstream distance from the duct inlet. This enhancement was greater at the duct ceiling and wall than at the duct floor. In insulated ducts, deposition enhancement was less pronounced overall than in steel ducts. Trends that were observed in steel ducts were present, but weaker, in insulated ducts.

  4. Study of natural ventilation design by integrating the multi-zone model with CFD simulation

    E-Print Network [OSTI]

    Tan, Gang, 1974-

    2005-01-01T23:59:59.000Z

    Natural ventilation is widely applied in sustainable building design because of its energy saving, indoor air qualify and indoor thermal environment improvement. It is important for architects and engineers to accurately ...

  5. Laboratory Ventilation SafetyLaboratory Ventilation Safety J. Scott WardJ. Scott Ward

    E-Print Network [OSTI]

    Farritor, Shane

    Laboratory Ventilation SafetyLaboratory Ventilation Safety J. Scott WardJ. Scott Ward #12;In 1925. Labconco CorporationLabconco Corporation #12;Laboratory VentilationLaboratory Ventilation #12;Laboratory Ventilation ProductsLaboratory Ventilation Products #12;History of Fume HoodsHistory of Fume Hoods Thomas

  6. A study of the air flow rates and their effects on bin drying sorghum grain with unheated air in South Texas

    E-Print Network [OSTI]

    Aldred, William H

    1956-01-01T23:59:59.000Z

    with the foot storage spoon use not availablo to hold their grain for s mors favorable market. Furthermore, only a limited amount of a~nial storage vss available at that time, These oonditions disolosed the need for infox- mstion consuming pxoesdurss.../ustment of the air flow to the desired rates was controlled bp two sliding gates in the latexal ss shown in Figure 5. Bzxcyle ports were installed in each bin at two levels ? one foot. from the bottom snd halfway between the bottom and the toy, This per- mitted...

  7. Ventilation | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov. Are you sure you wantJoin us for|Idahothe NewUtility-Scale Solar throughVentilation

  8. Smart Ventilation - RIVEC

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOriginEducationVideo »UsageSecretary ofSmall BusinessSecondary Ventilation Activity Inputs

  9. Natural vs. mechanical ventilation and cooling.

    E-Print Network [OSTI]

    Brager, Gail; Alspach, Peter; Nall, Daniel H.

    2011-01-01T23:59:59.000Z

    the drawbacks of each type of ventilation system helps theThe benefits of natural ventilation for occupants in com-In the strictest sense, “ventilation” refers to the exchange

  10. RATES

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Planning & Projects Power Marketing Rates You are here: SN Home page > Power Marketing > RATES Rates and Repayment Services Rates Current Rates FY 15 PRR worksheet (PDF - 31K) FY...

  11. TECHNICAL BASIS FOR VENTILATION REQUIREMENTS IN TANK FARMS OPERATING SPECIFICATIONS DOCUMENTS

    SciTech Connect (OSTI)

    BERGLIN, E J

    2003-06-23T23:59:59.000Z

    This report provides the technical basis for high efficiency particulate air filter (HEPA) for Hanford tank farm ventilation systems (sometimes known as heating, ventilation and air conditioning [HVAC]) to support limits defined in Process Engineering Operating Specification Documents (OSDs). This technical basis included a review of older technical basis and provides clarifications, as necessary, to technical basis limit revisions or justification. This document provides an updated technical basis for tank farm ventilation systems related to Operation Specification Documents (OSDs) for double-shell tanks (DSTs), single-shell tanks (SSTs), double-contained receiver tanks (DCRTs), catch tanks, and various other miscellaneous facilities.

  12. Reverse ventilation--perfusion mismatch

    SciTech Connect (OSTI)

    Palmaz, J.C.; Barnett, C.A.; Reich, S.B.; Krumpe, P.E.; Farrer, P.A.

    1984-01-01T23:59:59.000Z

    Patients having lobar airway obstruction or consolidation usually have decreases of both ventilation and perfusion on lung scans. We report three patients in whom hypoxic vasoconstriction was apparently incomplete, resulting in a ''reversed'' ventilation-perfusion mismatch. Perfusion of the hypoxic lobe on the radionuclide scan was associated with metabolic alkalosis, pulmonary venous and pulmonary arterial hypertension in these patients.

  13. Building America Webinar: Ventilation in Multifamily Buildings...

    Energy Savers [EERE]

    Ventilation in Multifamily Buildings Building America Webinar: Ventilation in Multifamily Buildings This webinar was presented by research team Consortium for Advanced Residential...

  14. FAQS Qualification Card - Confinement Ventilation and Process...

    Office of Environmental Management (EM)

    Confinement Ventilation and Process Gas Treatment FAQS Qualification Card - Confinement Ventilation and Process Gas Treatment A key element for the Department's Technical...

  15. Retrofit Ventilation Strategies in Multifamily Buildings Webinar...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Retrofit Ventilation Strategies in Multifamily Buildings Webinar Retrofit Ventilation Strategies in Multifamily Buildings Webinar Slides from the Building America webinar on...

  16. Solar Ventilation Preheating Resources and Technologies | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Ventilation Preheating Resources and Technologies Solar Ventilation Preheating Resources and Technologies Photo of a dark brown perforated metal wall is pictured on the side of an...

  17. RATES

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    RATES Rates Document Library SNR Rates Process Calendar (PDF - 171K) Procedures Informal Process Transmission Action Items List (PDF - 144K) Power Action Item List updated on...

  18. Assessment of Pollutant Spread from a Building Basement with three Ventilation Systems

    E-Print Network [OSTI]

    Koffi, Juslin

    2010-01-01T23:59:59.000Z

    Ventilation aims at providing a sufficient air renewal for ensuring a good indoor air quality (IAQ), yet building energy policies are leading to adapting various ventilation strategies minimising energy losses through air renewal. A recent IAQ evaluation campaign in French dwellings shows important pollution of living spaces by VOCs such as formaldehyde, acetaldehyde or hexanal, particularly in buildings equipped with a garage. Besides, radon emission from soil is a subject of concern in many countries. Several studies are done to understand its release mode and deal with the spread of this carcinogen gas. This paper aims to experimentally assess a contaminant spread from a house basement using mechanical exhaust and balanced ventilation systems, and natural ventilation.

  19. Particulate Air Pollution, Ambulatory Heart Rate Variability, and Cardiac Arrhythmia in Retirement Community Residents with Coronary Artery Disease

    E-Print Network [OSTI]

    Bartell, Scott M.; Longhurst, John; Tjoa, Thomas; Sioutas, Constantinos; Delfino, Ralph J.

    2013-01-01T23:59:59.000Z

    with traffic and air pollution in patients with coronary2009. A panel study of air pollution in subjects with heartcardia triggered by air pollution in patients with coronary

  20. Traffic-related air pollution exposures and changes in heart rate variability in Mexico City: A panel study

    E-Print Network [OSTI]

    2013-01-01T23:59:59.000Z

    to traffic-related air pollution and the risk of coronaryof particulate air pollution. Environ Health Perspect 2001,between ambient air pollution and daily mortality among

  1. Particulate air pollution, ambulatory heart rate variability, and cardiac arrhythmia in retirement community residents with coronary artery disease.

    E-Print Network [OSTI]

    Bartell, Scott M; Longhurst, John; Tjoa, Thomas; Sioutas, Constantinos; Delfino, Ralph J

    2013-01-01T23:59:59.000Z

    with traffic and air pollution in patients with coronary2009. A panel study of air pollution in subjects with heartcardia triggered by air pollution in patients with coronary

  2. Good ventilation is important

    E-Print Network [OSTI]

    by excess moisture. Because people spend about 90% of their time inside, indoor air pollution can actually be a bigger health risk than pollution in the air outside, even in crowded cities and industrial areas. 2, irritating pollutants, and potentially dangerous gases like carbon monoxide and radon. Well

  3. Natural Ventilation Applications in Hot-humid Climate: A Preliminary Design for the College of Design at NTUST 

    E-Print Network [OSTI]

    Lin, M. T.; Wei, H. Y.; Lin, Y. J.; Wu, H. F.; Liu, P. H.

    2010-01-01T23:59:59.000Z

    to create a comfortable architectural environment, especially in a hot, humid climate such as that of Taiwan. However, the air currents of urban wind fields are unpredictable and whimsical. The conventional architectural design process does not employ... the effectiveness of using natural ventilation for comfort, several factors have a strong impact on ventilation design schemes, namely objective analysis of the climatic profile, urban blocks and wind effects, and ventilation routes. These factors not only...

  4. Cardiac gated ventilation

    SciTech Connect (OSTI)

    Hanson, C.W. III [Hospital of the Univ. of Pennsylvania, Philadelphia, PA (United States). Dept. Anesthesia; Hoffman, E.A. [Univ. of Iowa College of Medicine, Iowa City, IA (United States). Div. of Physiologic Imaging

    1995-12-31T23:59:59.000Z

    There are several theoretic advantages to synchronizing positive pressure breaths with the cardiac cycle, including the potential for improving distribution of pulmonary and myocardial blood flow and enhancing cardiac output. The authors evaluated the effects of synchronizing respiration to the cardiac cycle using a programmable ventilator and electron beam CT (EBCT) scanning. The hearts of anesthetized dogs were imaged during cardiac gated respiration with a 50 msec scan aperture. Multi slice, short axis, dynamic image data sets spanning the apex to base of the left ventricle were evaluated to determine the volume of the left ventricular chamber at end-diastole and end-systole during apnea, systolic and diastolic cardiac gating. The authors observed an increase in cardiac output of up to 30% with inspiration gated to the systolic phase of the cardiac cycle in a non-failing model of the heart.

  5. RATES

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Marketing > RATES RATES Current Rates Past Rates 2006 2007 2008 2009 2010 2011 2012 Rates Schedules Power CV-F13 CPP-2 Transmissions CV-T3 CV-NWT5 PACI-T3 COTP-T3 CV-TPT7 CV-UUP1...

  6. Traffic-related air pollution exposures and changes in heart rate variability in Mexico City: A panel study

    E-Print Network [OSTI]

    2013-01-01T23:59:59.000Z

    variability with traffic and air pollution in patients withAtherosclerosis and Air Pollution (MESA Air). Am J Epidemiolto traffic-related air pollution and the risk of coronary

  7. Experimental Evaluation of Ventilation Systems in a Single-Family Dwelling

    E-Print Network [OSTI]

    Koffi, Juslin; Akoua, Jean-Jacques

    2010-01-01T23:59:59.000Z

    The French regulation on residential building ventilation relies on an overall and continuous air renewal. The fresh air should enter the building through the "habitable rooms" while the polluted air is extracted in the service rooms. In this way, internal air is drained from the lowest polluted rooms to the highest polluted ones. However, internal pressure equilibrium and air movements in buildings result from the combined effects ventilation system and parameters such as wind, temperature difference or doors opening. This paper aims to analyse the influence of these parameters on pollutant transfer within buildings. In so doing, experiments are carried out using tracer gas release for representing pollution sources in an experimental house. Mechanical exhaust, balanced and natural ventilation systems are thus tested. Results show the followings: - For all cases, internal doors' opening causes the most important pollutant spread. - When doors are closed, the best performances are obtained with balanced venti...

  8. Literature Review of Displacement Ventilation 

    E-Print Network [OSTI]

    Cho, S.; Im, P.; Haberl, J. S.

    2005-01-01T23:59:59.000Z

    . Energy Systems Laboratory, Texas A&M University System Page 9 IV. REFERENCES Chen, Q., Glicksman, L.R., Yuan, X., Hu, S. Yang, X. 1999. Performance evaluation and development of design guidelines for displacement ventilation, Final report... testing, and a tracer gas (CO 2 ) step-up procedure. Alamdari, F., Butler, D.J.G., Grigg, P.F., Shaw, M. R. 1998. Chilled ceilings and displacement ventilation. Renewable Energy, Vol. 15, Issues 1-4, pp. 300-305. Abstract: Displacement ventilation...

  9. anthropometry air displacement: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ventilation (DV) system and an underfloor air distribution (UFAD) system : building energy performance of the UFAD system. Open Access Theses and Dissertations Summary: ??As...

  10. Laboratory Ventilation Management Ralph Stuart, CHO

    E-Print Network [OSTI]

    Pawlowski, Wojtek

    Laboratory Ventilation Management Program Ralph Stuart, CHO Ellen Sweet, Laboratory Ventilation Specialist Cornell Department of Environmental Health and Safety 3/29/2013 #12;Laboratory Ventilation.1.2 Design and Construction Standards 10 7.1.3 Carbon Dioxide Ventilation Effectiveness Protocol 10 7.2 Job

  11. Formaldehyde Transfer in Residential Energy Recovery Ventilators

    E-Print Network [OSTI]

    ;1. INTRODUCTION Mechanical ventilation systems were once considered unnecessary for single-family, US homes

  12. Literature Review of Displacement Ventilation

    E-Print Network [OSTI]

    Cho, S.; Im, P.; Haberl, J. S.

    Performance Evaluation and Design Guidelines for Displacement Ventilation” by Chen and Clicksman (2003), were used to begin the literature search. Their references include papers, articles, and web sites presenting major contributions to the understanding...

  13. Deep-Sea Coral Evidence for Rapid Change in Ventilation of the Deep North Atlantic

    E-Print Network [OSTI]

    Adkins, Jess F.

    Deep-Sea Coral Evidence for Rapid Change in Ventilation of the Deep North Atlantic 15,400 Years Ago radiocarbon and thorium-230 dates from benthic coral species reveal that the ventilation rate of the North to interstadials of longer dura- tion (5). One problem has been that the time resolution of sediments is limited

  14. Building America Case Study: Selecting Ventilation Systems for Existing Homes (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-12-01T23:59:59.000Z

    This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

  15. Indoor-Atmospheric Radon-Related Radioactivity Affected by a Change of Ventilation Strategy

    E-Print Network [OSTI]

    Kobayashi, T

    2006-01-01T23:59:59.000Z

    The present author has kept observation for concentrations of atmospheric radon, radon progeny and thoron progeny for several years at the campus of Fukushima Medical University. Accidentally, in the midst of an observation term, i.e., February 2005, the facility management group of the university changed a strategy for the manner of ventilation, probably because of a recession: (I) tidy everyday ventilation of 7:30-24:00 into (II) shortened weekday ventilation of 8:00-21:00 with weekend halts. This change of ventilation manner brought a clear alteration for the concentrations of radon-related natural radioactivity in indoor air. The present paper concerns an investigation of the effect of the ventilation strategy on the indoor-atmospheric radon-related radioactivity.

  16. Optimization of Occupancy Based Demand Controlled Ventilation in Residences

    E-Print Network [OSTI]

    Mortensen, Dorthe K.

    2012-01-01T23:59:59.000Z

    of intermittent ventilation for providing acceptable indoor253. CEN, EN15665: Ventilation for buildings - Determiningcriteria for residential ventilation systems, 2009. CEN,

  17. Summary of Workshop: Barriers to Energy Efficient Residential Ventilation

    E-Print Network [OSTI]

    Sherman, Max

    2008-01-01T23:59:59.000Z

    Improved controls for ventilation systems, including betterEfficient Residential Ventilation Held on January 10, 2008Consumers Manufacturers / Ventilation Industry Public Sector

  18. On The Valuation of Infiltration towards Meeting Residential Ventilation Needs

    E-Print Network [OSTI]

    Sherman, Max H.

    2008-01-01T23:59:59.000Z

    Related to Residential Ventilation Requirements”. LBNLP.N. and M.H. Sherman "Ventilation Behavior and HouseholdReview of Residential Ventilation Technologies”, LBNL 57730.

  19. Advanced Controls and Sustainable Systems for Residential Ventilation

    E-Print Network [OSTI]

    1 Advanced Controls and Sustainable Systems for Residential Ventilation William J.N. Turner & Iain..................................................................................................................... 8 Residential Ventilation Standards..........................................................................................9 Passive and Hybrid Ventilation

  20. CO2 MONITORING FOR DEMAND CONTROLLED VENTILATION IN COMMERCIAL BUILDINGS

    E-Print Network [OSTI]

    Fisk, William J.

    2010-01-01T23:59:59.000Z

    use of demand control ventilation systems in general officethe demand controlled ventilation system increased the ratedemand controlled ventilation systems will, because of poor

  1. Optimization of Occupancy Based Demand Controlled Ventilation in Residences

    E-Print Network [OSTI]

    Mortensen, Dorthe K.

    2012-01-01T23:59:59.000Z

    for residential ventilation systems, 2009. CEN, EN15251:The demand controlled ventilation system operated at a lowthe whole house ventilation system that implicitly assumes

  2. On The Valuation of Infiltration towards Meeting Residential Ventilation Needs

    E-Print Network [OSTI]

    Sherman, Max H.

    2008-01-01T23:59:59.000Z

    from steady mechanical ventilation system. For the case ofbecause unbalanced mechanical ventilation systems change theoften need mechanical ventilation systems to meet current

  3. Advanced Controls and Sustainable Systems for Residential Ventilation

    E-Print Network [OSTI]

    Turner, William J.N.

    2014-01-01T23:59:59.000Z

    through dynamic control of ventilation systems. Energy andcontinuous mechanical ventilation systems a mean annualcompliant ASHRAE 62.2 ventilation system. Table 12: Average

  4. Classroom HVAC: Improving ventilation and saving energy -- field study plan

    E-Print Network [OSTI]

    Apte, Michael G.; Faulkner, David; Hodgson, Alfred T.; Sullivan, Douglas P.

    2004-01-01T23:59:59.000Z

    in this study. Classroom HVAC: Improving Ventilation andV8doc.sas.com/sashtml. Classroom HVAC: Improving VentilationBerkeley, CA 94720. Classroom HVAC: Improving Ventilation

  5. Particle deposition from turbulent flow: Review of published research and its applicability to ventilation ducts in commercial buildings

    SciTech Connect (OSTI)

    Sippola, Mark R.; Nazaroff, William W.

    2002-06-01T23:59:59.000Z

    This report reviews published experimental and theoretical investigations of particle deposition from turbulent flows and considers the applicability of this body of work to the specific case of particle deposition from flows in the ducts of heating, ventilating and air conditioning (HVAC) systems. Particle deposition can detrimentally affect the performance of HVAC systems and it influences the exposure of building occupants to a variety of air pollutants. The first section of this report describes the types of HVAC systems under consideration and discusses the components, materials and operating parameters commonly found in these systems. The second section reviews published experimental investigations of particle deposition rates from turbulent flows and considers the ramifications of the experimental evidence with respect to HVAC ducts. The third section considers the structure of turbulent airflows in ventilation ducts with a particular emphasis on turbulence investigations that have been used as a basis for particle deposition models. The final section reviews published literature on predicting particle deposition rates from turbulent flows.

  6. Infiltration Effects on Residential Pollutant Concentrations for Continuous and Intermittent Mechanical Ventilation Approaches

    SciTech Connect (OSTI)

    Sherman, Max; Logue, Jennifer; Singer, Brett

    2010-06-01T23:59:59.000Z

    The prevailing residential ventilation standard in North America, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 62.2, specifies volumetric airflow requirements as a function of the overall size of the home and the number of bedrooms, assumes a fixed, minimal amount of infiltration, and requires mechanical ventilation to achieve the remainder. The standard allows for infiltration credits and intermittent ventilation patterns that can be shown to provide comparable performance. Whole-house ventilation methods have a substantial effect on time-varying indoor pollutant concentrations. If alternatives specified by Standard 62.2, such as intermittent ventilation, are used, short-term pollutant concentrations could exceed acute health standards even if chronic health standards are met.The authors present a methodology for comparing ASHRAE- and non-ASHRAE-specified ventilation scenarios on relative indoor pollutant concentrations. We use numerical modeling to compare the maximum time-averaged concentrations for acute exposure relevant (1-hour, 8-hour, 24-hour ) and chronic exposure relevant (1-year) time periods for four different ventilation scenarios in six climates with a range of normalized leakage values. The results suggest that long-term concentrations are the most important metric for assessing the effectiveness of whole-house ventilation systems in meeting exposure standards and that, if chronic health exposure standards are met, acute standards will also be met.

  7. Energy and first costs analysis of displacement and mixing ventilation systems for U.S. buildings and climates

    E-Print Network [OSTI]

    Hu, ShiPing, 1970-

    1999-01-01T23:59:59.000Z

    In the past two decades, displacement ventilation has been increasingly used in Scandinavia and Western Europe to improve indoor air quality and to save energy. By using a detailed computer simulation method, this study ...

  8. Comparison of Two Ventilation Systems in a Chinese Commercial Kitchen 

    E-Print Network [OSTI]

    Wan, X.; Yu, L.; Hou, H.

    2006-01-01T23:59:59.000Z

    ICEBO2006, Shenzhen, China HVAC Technologies for Energy Efficiency, Vol. IV-7-4 Comparison of Two Ventilation Systems in a Chinese Commercial Kitchen Xiongfeng Wan Likui Yu Huabo Hou Master Associate professor Master... viscosity; ? represents thermal expansion coefficient of air; T0 represents temperature of a reference point; T represents temperature; i represents gravity acceleration in i-direction. And the effective viscosity, eff? , equals the sum...

  9. Availability Analysis of the Ventilation Stack CAM Interlock System

    E-Print Network [OSTI]

    Young, J

    2000-01-01T23:59:59.000Z

    Ventilation Stack Continuous Air Monitor (CAM) Interlock System failure modes, failure frequencies, and system availability have been evaluated for the RPP. The evaluation concludes that CAM availability is as high as assumed in the safety analysis and that the current routine system surveillance is adequate to maintain this availability credited in the safety analysis, nor is such an arrangement predicted to significantly improve system availability.

  10. Residential ventilation standards scoping study

    SciTech Connect (OSTI)

    McKone, Thomas E.; Sherman, Max H.

    2003-10-01T23:59:59.000Z

    The goals of this scoping study are to identify research needed to develop improved ventilation standards for California's Title 24 Building Energy Efficiency Standards. The 2008 Title 24 Standards are the primary target for the outcome of this research, but this scoping study is not limited to that timeframe. We prepared this scoping study to provide the California Energy Commission with broad and flexible options for developing a research plan to advance the standards. This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the ventilation needs of California residences, determining the bases for setting residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and corresponding levels of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  11. 7-111 A Carnot heat engine is used to drive a Carnot refrigerator. The maximum rate of heat removal from the refrigerated space and the total rate of heat rejection to the ambient air are to be determined.

    E-Print Network [OSTI]

    Bahrami, Majid

    7-42 7-111 A Carnot heat engine is used to drive a Carnot refrigerator. The maximum rate of heat removal from the refrigerated space and the total rate of heat rejection to the ambient air are to be determined. Assumptions The heat engine and the refrigerator operate steadily. Analysis (a) The highest

  12. Summary of Workshop: Barriers to Energy Efficient Residential Ventilation

    E-Print Network [OSTI]

    Sherman, Max

    2008-01-01T23:59:59.000Z

    for whole-house ventilation, local exhaust ventilation,by mechanical ventilation. Standard 62.2 also requires localVentilation • Mechanical system meeting Section 4 or 'other methods" when approved by LDP • Local

  13. Optical People Counting for Demand Controlled Ventilation: A Pilot Study of Counter Performance

    SciTech Connect (OSTI)

    Fisk, William J.; Sullivan, Douglas

    2009-12-26T23:59:59.000Z

    This pilot scale study evaluated the counting accuracy of two people counting systems that could be used in demand controlled ventilation systems to provide control signals for modulating outdoor air ventilation rates. The evaluations included controlled challenges of the people counting systems using pre-planned movements of occupants through doorways and evaluations of counting accuracies when naive occupants (i.e., occupants unaware of the counting systems) passed through the entrance doors of the building or room. The two people counting systems had high counting accuracy accuracies, with errors typically less than 10percent, for typical non-demanding counting events. However, counting errors were high in some highly challenging situations, such as multiple people passing simultaneously through a door. Counting errors, for at least one system, can be very high if people stand in the field of view of the sensor. Both counting system have limitations and would need to be used only at appropriate sites and where the demanding situations that led to counting errors were rare.

  14. Sorbent-Based Gas Phase Air Cleaning for VOCs in CommercialBuildings

    SciTech Connect (OSTI)

    Fisk, William J.

    2006-05-01T23:59:59.000Z

    This paper provides a review of current knowledge about the suitability of sorbent-based air cleaning for removing volatile organic compounds (VOCs) from the air in commercial buildings as needed to enable reductions in ventilation rates and associated energy savings. The fundamental principles of sorbent air cleaning are introduced, criteria are suggested for sorbent systems that can counteract indoor VOC concentration increases from reduced ventilation, major findings from research on sorbent performance for this application are summarized, novel sorbent technologies are described, and related priority research needs are identified. Major conclusions include: sorbent systems can remove a broad range of VOCs with moderate to high efficiency, sorbent technologies perform effectively when challenged with VOCs at the low concentrations present indoors, and there is a large uncertainty about the lifetime and associated costs of sorbent air cleaning systems when used in commercial buildings for indoor VOC control. Suggested priority research includes: experiments to determine sorbent system VOC removal efficiencies and lifetimes considering the broad range and low concentration of VOCs indoors; evaluations of in-situ regeneration of sorbents; and an updated analysis of the cost of sorbent air cleaning relative to the cost of ventilation.

  15. SIMPLIFIED METHODS FOR COMBINING MECHANICAL VENTILATION AND NATURAL INFILTRATION

    E-Print Network [OSTI]

    Modera, M.

    2011-01-01T23:59:59.000Z

    of Heating and Ventilating, Royal Institute of Technology,Heating and Ventilating The Royal Institute of Technology

  16. Ventilation-Synchronous Magnetic Resonance Microscopy of Pulmonary Structure and Ventilation in

    E-Print Network [OSTI]

    Ventilation-Synchronous Magnetic Resonance Microscopy of Pulmonary Structure and Ventilation helium (3 He) gas to acquire images that dem- onstrate pulmonary vasculature and ventilated airways of these structures relative to the less vascular surrounding tissues. A constant- flow ventilator was developed

  17. We compared the efficacy of positive pressure ventilation (PPV) vs negative pressure ventilation (NPV) in providing

    E-Print Network [OSTI]

    Shadmehr, Reza

    the rationale for the use ofintermittent assisted ventilation is based on the premise that it alleviates muscleWe compared the efficacy of positive pressure ventilation (PPV) vs negative pressure ventilationEMG), minute ventilation (VE),tidal volume (VT), and end-tidal CO (etCOĂ during 15 minutes of PPV and NPV

  18. Building America Webinar: Retrofit Ventilation Strategies in...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Strategies in Multifamily Buildings Webinar Building America Webinar: Retrofit Ventilation Strategies in Multifamily Buildings Webinar This webinar, presented by...

  19. Integrated Technology Air Cleaners (ITAC): Design and Evaluation

    SciTech Connect (OSTI)

    Fisk, William J.; Cohn, Sebastian; Destaillats, Hugo; Henzel, Victor; Sidheswaran, Meera; Sullivan, Douglas P.

    2013-09-13T23:59:59.000Z

    The primary objective of this project was to design, build, and test an air cleaner for residential use with the potential to substantially improve indoor air quality, or maintain indoor air quality unchanged, when outdoor air ventilation rates are reduced to save energy. Two air cleaners were designed and fabricated. The design targets for airflow rate, fan power, and projected cost were met. In short term laboratory studies, both units performed as expected; however, during field studies in homes, the formaldehyde removal performance of the air cleaners was much lower than expected. In subsequent laboratory studies, incomplete decomposition of some indoor air volatile organic compounds, with formaldehyde as a product of partial decomposition of volatile organic compounds, was confirmed as the explanation for the poor formaldehyde removal performance in the field studies. The amount of formaldehyde produced per unit of decomposition of other volatile organic compounds was substantially diminished by increasing the amount of catalyst on the filter and also by decreasing the air velocity. Together, these two measures reduced formaldehyde production, per unit destruction of other volatile organic compounds, by a factor of four, while increasing the removal efficiency of volatile organic compounds by a factor of 1.4. A company with a southern California office is conducting studies in conjunction with Lawrence Berkeley National Laboratory, with the goal of incorporating the ITAC catalytic air cleaning technology in their future commercial products.

  20. Procedures and Standards for Residential Ventilation System

    E-Print Network [OSTI]

    1 Procedures and Standards for Residential Ventilation System Commissioning: An Annotated and by the California Energy Commission under Pier Contract 500-08-061. Key terms: residential, ventilation.C. and C.P. Wray. 2013. Procedures and Standards for Residential Ventilation System Commissioning

  1. Humidity Implications for Meeting Residential Ventilation Requirements

    E-Print Network [OSTI]

    1 LBNL-62182 Humidity Implications for Meeting Residential Ventilation Requirements Iain S. Walker for Meeting Residential Ventilation Requirements ABSTRACT In 2003 ASHRAE approved the nation's first residential ventilation standard, ASHRAE Standard 62.2. Because meeting this standard can significantly change

  2. Experimental Determination of ETS Particle Deposition in a Low Ventilation Room

    SciTech Connect (OSTI)

    Xu, M.; Nematollahi, M.; Sextro, R.G.; Gadgil, A.J.; Nazaroff, W.W.

    1993-05-01T23:59:59.000Z

    Deposition on indoor surfaces is an important removal mechanism for tobacco smoke particles. We report measurements of deposition rates of environmental tobacco smoke particles in a room-size chamber. The deposition rates were determined from the changes in measured concentrations by correcting for the effects of coagulation and ventilation. The air flow turbulent intensity parameter was determined independently by measuring the air velocities in the chamber. Particles with diameters smaller than 0.25 {micro}m coagulate to form larger particles of sizes between 0.25-0.5 {micro}m. The effect of coagulation on the particles larger than 0.5 {micro}m was found to be negligible. Comparison between our measurements and calculations using Crump and Seinfeld's theory showed smaller measured deposition rates for particles from 0.1 to 0.3 {micro}m in diameter and greater measured deposition rates for particles larger than 0.6 {micro}m at three mixing intensities. Comparison of Nazaroff and Cass model for natural convection flow showed good agreement with the measurements for particles larger than 0.1 {micro}m in diameter, however, measured deposition rates exceeded model prediction by a factor of approximately four for particles in size range 0.05-0.1 {micro}m diameter. These results were used to predict deposition of sidestream smoke particles on interior surfaces. Calculations predict that in 10 hours after smoking one cigarette, 22% of total sidestream particles by mass will deposit on interior surfaces at 0.03 air change per hour (ACH), 6% will deposit at 0.5 ACH, and 3% will deposit at 1 ACH.

  3. Recirculation of Factory Heat and Air to Reduce Energy Consumption

    E-Print Network [OSTI]

    Thiel, G. R.

    1983-01-01T23:59:59.000Z

    the energy cost of make-up air, without sacrificing in-plant air quality. Source-capture Ventilation employs engineered sys tems that confine airborne contaminants at their point of origin, before they can escape into plant air (Figures 3, 4... the workers' breathing zones or the general plant air, they can achieve virtually 100% elimination of airborne pollutants. But they entail the expense of enclosure and/or hooding and duct systems. General ventilation, though simpler and often less costly...

  4. Utilization of coal mine ventilation exhaust as combustion air in gas-fired turbines for electric and/or mechanical power generation. Semi-annual topical report, June 1995--August 1995

    SciTech Connect (OSTI)

    NONE

    1995-12-01T23:59:59.000Z

    Methane emitted during underground coal mining operations is a hazard that is dealt with by diluting the methane with fresh air and exhausting the contaminated air to the atmosphere. Unfortunately this waste stream may contain more than 60% of the methane resource from the coal, and in the atmosphere the methane acts as a greenhouse gas with an effect about 24.5 times greater than CO{sub 2}. Though the waste stream is too dilute for normal recovery processes, it can be used as combustion air for a turbine-generator, thereby reducing the turbine fuel requirements while reducing emissions. Preliminary analysis indicates that such a system, built using standard equipment, is economically and environmentally attractive, and has potential for worldwide application.

  5. Impacts of Mixing on Acceptable Indoor Air Quality in Homes

    E-Print Network [OSTI]

    , and contaminant source and occupant locations. Most U.S. and Canadian homes have central heating, ventilation Ventilation reduces occupant exposure to indoor contaminants by diluting or removing them. In a multi. The total ventilation rate is the most important factor in determining occupant exposure to given

  6. Dry Transfer Facility #1 - Ventilation Confinement Zoning Analysis

    SciTech Connect (OSTI)

    K.D. Draper

    2005-03-23T23:59:59.000Z

    The purpose of this analysis is to establish the preliminary Ventilation Confinement Zone (VCZ) for the Dry Transfer Facility (DTF). The results of this document is used to determine the air quantities for each VCZ that will eventually be reflected in the development of the Ventilation Flow Diagrams. The calculations contained in this document were developed by D and E/Mechanical-HVAC and are intended solely for the use of the D and E/Mechanical-HVAC department in its work regarding the HVAC system for the Dry Transfer Facility. Yucca Mountain Project personnel from the D and E/Mechanical-HVAC department should be consulted before use of the calculation for purposes other than those stated herein or used by individuals other than authorized personnel in D and E/Mechanical-HVAC department.

  7. Acceptance test report, 241-AW air inlet filter station pressure decay test

    SciTech Connect (OSTI)

    Tuck, J.A.

    1996-02-21T23:59:59.000Z

    This is the acceptance test report for pressure decay tests performed on newly-installed 241-AW Tank Farm primary ventilation system air inlet filter stations.

  8. air-conditioning equipment lorentz: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Topic Index 1 Smart School Symposium Heating Ventilation and Air Conditioning Session Energy Storage, Conversion and Utilization Websites Summary: Smart School Symposium Heating...

  9. Air Leakage and Air Transfer Between Garage and Living Space

    SciTech Connect (OSTI)

    Rudd, A.

    2014-09-01T23:59:59.000Z

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  10. Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-02-01T23:59:59.000Z

    Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems - a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms - were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

  11. In this study we investigate whether limb movements hinder or assist lung ventilation during turtle locomotion. A peculiar

    E-Print Network [OSTI]

    Brainerd, Elizabeth

    In this study we investigate whether limb movements hinder or assist lung ventilation during turtle). The rigid turtle shell contains a relatively fixed volume, thereby causing the air within the lungs and amphibians, forcing air into the lungs under positive pressure, but numerous experimental investigations have

  12. Field-Evaluation of Alternative HVAC Strategies to Meet Ventilation, Comfort and Humidity Control Criteria at Three Full-Serve Restaurants

    E-Print Network [OSTI]

    Yborra, S. C.; Spears, J. W.

    2000-01-01T23:59:59.000Z

    Lighting and ventilation represent the majority of the air conditioning loads in office buildings in hot humid climates. Use of motion sensors is one way to minimize the energy used for these loads. This paper describes the methods used...

  13. A Model for Evaluation of Life-Cycle Energy Savings of Occupancy Sensors for Control of Lighting and Ventilation in Office Buildings 

    E-Print Network [OSTI]

    Degelman, L. O.

    2000-01-01T23:59:59.000Z

    Lighting and ventilation represent the majority of the air conditioning loads in office buildings in hot humid climates. Use of motion sensors is one way to minimize the energy used for these loads. This paper describes the methods used...

  14. Field-Evaluation of Alternative HVAC Strategies to Meet Ventilation, Comfort and Humidity Control Criteria at Three Full-Serve Restaurants 

    E-Print Network [OSTI]

    Yborra, S. C.; Spears, J. W.

    2000-01-01T23:59:59.000Z

    Lighting and ventilation represent the majority of the air conditioning loads in office buildings in hot humid climates. Use of motion sensors is one way to minimize the energy used for these loads. This paper describes the methods used...

  15. A Model for Evaluation of Life-Cycle Energy Savings of Occupancy Sensors for Control of Lighting and Ventilation in Office Buildings

    E-Print Network [OSTI]

    Degelman, L. O.

    2000-01-01T23:59:59.000Z

    Lighting and ventilation represent the majority of the air conditioning loads in office buildings in hot humid climates. Use of motion sensors is one way to minimize the energy used for these loads. This paper describes the methods used...

  16. Solar Ventilation Preheating Resources and Technologies

    Broader source: Energy.gov [DOE]

    This page provides a brief overview of solar ventilation preheating (SVP) technologies supplemented by specific information to apply SVP within the Federal sector.

  17. Development of a Residential Integrated Ventilation Controller

    E-Print Network [OSTI]

    Walker, Iain

    2013-01-01T23:59:59.000Z

    systems such as those sold by Honeywell, and Aprilaire. Forin the world. Honeywell (http://yourhome.honeywell.com/US/Products/Ventilation/ ) Honeywell makes a line of economy

  18. Experimental Study of the Floor Radiant Cooling System Combined with Displacement Ventilation

    E-Print Network [OSTI]

    Ren, Y.; Li, D.; Zhang, Y.

    2006-01-01T23:59:59.000Z

    and developed measures for preventing it. The dry air layer near the floor formed by a displacement ventilation system can effectively prevent dews on the surface of the floor in the wet and hot days in summer. In addition, for the sake of the displacement...

  19. Laboratory Performance Testing of Residential Window Air Conditioners

    SciTech Connect (OSTI)

    Winkler, J.; Booten, C.; Christensen, D.; Tomerlin, J.

    2013-03-01T23:59:59.000Z

    Window air conditioners are the dominant cooling product for residences, in terms of annual unit sales. They are inexpensive, portable and can be installed by the owner. For this reason, they are an attractive solution for supplemental cooling, for retrofitting air conditioning into a home which lacks ductwork, and for renters. Window air conditioners for sale in the United States are required to meet very modest minimum efficiency standards. Four window air conditioners' performance were tested in the Advanced HVAC Systems Laboratory on NREL's campus in Golden, CO. In order to separate and study the refrigerant system's performance, the unit's internal leakage pathways, the unit's fanforced ventilation, and the leakage around the unit resulting from installation in a window, a series of tests were devised that focused on each aspect of the unit's performance. These tests were designed to develop a detailed performance map to determine whole-house performance in different climates. Even though the test regimen deviated thoroughly from the industry-standard ratings test, the results permit simple calculation of an estimated rating for both capacity and efficiency that would result from a standard ratings test. Using this calculation method, it was found that the three new air conditioners' measured performance was consistent with their ratings. This method also permits calculation of equivalent SEER for the test articles. Performance datasets were developed across a broad range of indoor and outdoor operating conditions, and used them to generate performance maps.

  20. Natural Ventilation | Department of Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency VisitSilver Toyota1Resourceloading newNatural Ventilation

  1. Ventilation Behavior and Household Characteristics in New California Houses

    E-Print Network [OSTI]

    Price, Phillip N.; Sherman, Max H.

    2006-01-01T23:59:59.000Z

    and Mechanical Ventilation: Use of Local Exhaust Fans:pollutants. Large ventilation fans can cause local thermallocal contaminants such as those from kitchen and bathroom activities, then minimum building ventilation

  2. External Authorities and Peers Laboratory Ventilation Management Program

    E-Print Network [OSTI]

    Pawlowski, Wojtek

    External Authorities and Peers Laboratory Ventilation Management Program Guidance Document External Authorities and Peers This group encompasses external groups who do not manage laboratory ventilation systems to laboratory ventilation management. Roles Responsibilities Tracking Indicator Laboratory science peers

  3. HVAC EFFICIENCY BUSINESS CASE DEMAND CONTROL KITCHEN VENTILATION

    E-Print Network [OSTI]

    California at Davis, University of

    HVAC EFFICIENCY BUSINESS CASE DEMAND CONTROL KITCHEN VENTILATION Selecting, financing ventilation (DCKV) for kitchen exhaust hoods. Implementation can be relatively simple in either new of demand control kitchen ventilation (DCKV) in many small, medium, and large kitchen exhaust hood

  4. RESEARCH ARTICLE Open Access Noninvasive ventilation reduces energy

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    RESEARCH ARTICLE Open Access Noninvasive ventilation reduces energy expenditure in amyotrophic with a shift of the burden of ventilation to extradiaphragmatic inspiratory muscles, including neck muscles prognostic value. We hypothesized that noninvasive ventilation (NIV) would relieve inspiratory neck muscles

  5. ENERGY IMPACTS OF VARIOUS RESIDENTIAL MECHANICAL VENTILATION STRATEGIES 

    E-Print Network [OSTI]

    Vieira, R.; Parker, D.; Lixing, G.; Wichers, M.

    2008-01-01T23:59:59.000Z

    . Enthalpy recovery ventilation units tend to use more energy overall - despite the heat recovery - than supply or exhaust only ventilation systems, due to using twice as much fan energy. This paper presents simulation results for eight ventilation strategies...

  6. Traffic-related air pollution exposures and changes in heart rate variability in Mexico City: A panel study

    E-Print Network [OSTI]

    Shields, Kyra Naumoff

    Abstract Background While air pollution exposures have been linked to cardiovascular outcomes, the contribution from acute gas and particle traffic-related pollutants remains unclear. Using a panel study design with repeated ...

  7. Hybrid Ventilation Optimization and Control Research and Development...

    Energy Savers [EERE]

    Hybrid Ventilation Optimization and Control Research and Development Hybrid Ventilation Optimization and Control Research and Development Lead Performer: Massachusetts Institute of...

  8. Ventilation System to Improve Savannah River Site's Liquid Waste...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Ventilation System to Improve Savannah River Site's Liquid Waste Operations Ventilation System to Improve Savannah River Site's Liquid Waste Operations August 28, 2014 - 12:00pm...

  9. Case Study - The Challenge: Improving Ventilation System Energy...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Ventilation System Energy Efficiency in a Textile Plant Case Study - The Challenge: Improving Ventilation System Energy Efficiency in a Textile Plant This case study examines how...

  10. Workers Remove Glove Boxes from Ventilation at Hanford's Plutonium...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Remove Glove Boxes from Ventilation at Hanford's Plutonium Finishing Plant Workers Remove Glove Boxes from Ventilation at Hanford's Plutonium Finishing Plant January 28, 2015 -...

  11. Critical Question #2: What are the Best Practices for Ventilation...

    Energy Savers [EERE]

    2: What are the Best Practices for Ventilation Specific to Multifamily Buildings? Critical Question 2: What are the Best Practices for Ventilation Specific to Multifamily...

  12. Summer Infiltration/Ventilation Test Results from the FRTF Laboratory...

    Energy Savers [EERE]

    Summer InfiltrationVentilation Test Results from the FRTF Laboratory Summer InfiltrationVentilation Test Results from the FRTF Laboratory This presentation was delivered at the...

  13. Literature Review on Underfloor Air Distribution (UFAD) Systems

    E-Print Network [OSTI]

    Im, P.; Cho, S.; Haberl, J. S.

    2006-01-10T23:59:59.000Z

    ) ..................................................... 6 3.5. Task Ventilation Systems ................................................................................. 7 3.6. Recommendations from Experiences.............................................................. 8 IV. SUMMARY... transactions and journal papers are main sources about the UFAD systems. (More than 100 papers found) Elsevier Literature Search Engine: Keyword: Displacement Ventilation (26 papers found) Keyword: UnderFloor Air Distribution (2 papers found) Center...

  14. E-Print Network 3.0 - apheis project air Sample Search Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to supply rooms with air that is "conditioned"--that is, heated or cooled... by the heating, ventilation, and air conditioning (HVAC) equipment--and to recirculate or return...

  15. E-Print Network 3.0 - air-distribution systems interactions Sample...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    system designer does not know how to design the best air distribution method for an ice rink. Ice rink... of the effectiveness of ventilation system and air distribution method....

  16. Flywheel Cooling: A Cooling Solution for Non Air-Conditioned Buildings

    E-Print Network [OSTI]

    Abernethy, D.

    of evaroration, ventilation and air circulation. These systems are rroviding low-cost cooling for distribution centers, warehouses, and other non air-conditioned industrial assembly rlants with little or no internal 10iids. . The eva[lorative roof cooling...

  17. Sensor for Individual Burner Control of Coal Firing Rate, Fuel-Air Ratio and Coal Fineness Correlation

    SciTech Connect (OSTI)

    R. Demler

    2006-04-01T23:59:59.000Z

    Accurate, cost-efficient monitoring instrumentation has long been considered essential to the operation of power plants. Nonetheless, for the monitoring of coal flow, such instrumentation has been sorely lacking and technically difficult to achieve. With more than half of the electrical power in the United States currently supplied by coal, energy generated by this resource is critical to the US economy. The demand for improvement in this area has only increased as a result of the following two situations: First, deregulation has produced a heightened demand for both reduced electrical cost and improved grid connectivity. Second, environmental concerns have simultaneously resulted in a need for both increased efficiency and reduced carbon and NOx emissions. A potential approach to addressing both these needs would be improvement in the area of combustion control. This would result in a better heat rate, reduced unburned carbon in ash, and reduced NOx emissions. However, before feedback control can be implemented, the ability to monitor coal flow to the burners in real-time must be established. While there are several ''commercially available'' products for real-time coal flow measurement, power plant personnel are highly skeptical about the accuracy and longevity of these systems in their current state of development. In fact, following several demonstration projects of in-situ coal flow measurement systems in full scale utility boilers, it became obvious that there were still many unknown influences on these instruments during field applications. Due to the operational environment of the power plant, it has been difficult if not impossible to sort out what parameters could be influencing the various probe technologies. Additionally, it has been recognized for some time that little is known regarding the performance of coal flow splitters, even where rifflers are employed. Often the coal flow distribution from these splitters remains mal-distributed. There have been mixed results in the field using variable orifices in coal pipes. Development of other coal flow control devices has been limited. An underlying difficulty that, to date, has hindered the development of an accurate instrument for coal flow measurements is the fact that coal flow is characterized by irregular temporal and spatial variation. However, despite the inherent complexity of the dynamic system, the system is in fact deterministic. Therefore, in principle, the coal flow can be deduced from the dynamics it exhibits. Nonetheless, the interactions are highly nonlinear, rendering standard signal processing approaches, which rely on techniques such as frequency decomposition, to be of little value. Foster-Miller, Inc. has developed a methodology that relates the complex variation in such systems to the information of interest. This technology will be described in detail in Section 2. A second concern regarding the current measurement systems is installation, which can be labor-intensive and cost-prohibitive. A process that does not require the pulverizer to be taken off line would be highly desirable. Most microwave and electrostatic methods require drilling up to 20 holes in the pipe, all with a high degree of precision so as to produce a proper alignment of the probes. At least one electrostatic method requires a special spool piece to be fitted into each existing coal pipe. Overall, these procedures are both difficult and very expensive. An alternative approach is pursued here, namely the development of an instrument that relies on an acoustic signal captured by way of a commercial accelerometer. The installation of this type of sensor is both simpler and less invasive than other techniques. An accelerometer installed in a pipe wall need not penetrate through the wall, which means that the system may be able to remain on line during the installation. Further, due to the fact that the Dynamical Instruments technology, unlike other systems, does not rely on uniformity of the air or coal profile, the installation location need not be on a long, straight run

  18. Inspection and Gamma-Ray Dose Rate Measurements of the Annulus of the VSC-17 Concrete Spent Nuclear Fuel Storage Cask

    SciTech Connect (OSTI)

    P. L. Winston

    2007-09-01T23:59:59.000Z

    The air cooling annulus of the Ventilated Storage Cask (VSC)-17 spent fuel storage cask was inspected using a Toshiba 7 mm (1/4”) CCD video camera. The dose rates observed in the annular space were measured to provide a reference for the activity to which the camera(s) being tested were being exposed. No gross degradation, pitting, or general corrosion was observed.

  19. The integration of engineering and architecture: A perspective on natural ventilation for the new San Francisco Federal Building

    SciTech Connect (OSTI)

    McConahey, Erin; Haves, Philip; Christ, Tim

    2002-05-31T23:59:59.000Z

    A description of the in-progress design of a new Federal Office Building for San Francisco is used to illustrate a number of issues arising in the design of large, naturally ventilated office buildings. These issues include the need for an integrated approach to design involving the architects, mechanical and structural engineers, lighting designers and specialist simulation modelers. In particular, the use of natural ventilation, and the avoidance of air-conditioning, depends on the high degree of exposed thermal mass made possible by the structural scheme and by the minimization of solar heat gains while maintaining the good daylighting that results from optimization of the fagade. Another issue was the need for a radical change in interior space planning in order to enhance the natural ventilation; all the individual enclosed offices are located along the central spine of each floorplate rather than at the perimeter. The role of integration in deterring the undermining of the design through value engineering is discussed. The comfort criteria for the building were established based on the recent extension to the ASHRAE comfort standard based on the adaptive model for naturally ventilated buildings. The building energy simulation program EnergyPlus was used to compare the performance of different natural ventilation strategies. The results indicate that, in the San Francisco climate, wind-driven ventilation provides sufficient nocturnal cooling to maintain comfortable conditions and that external chimneys do not provide significant additional ventilation at times when it when it would be beneficial.

  20. Evaluation of Ultra-Violet Photocatalytic Oxidation for Indoor AirApplications

    SciTech Connect (OSTI)

    Hodgson, A.T.; Sullivan, D.P.; Fisk, W.J.

    2006-02-01T23:59:59.000Z

    Acceptable indoor air quality in office buildings may be achieved with less energy by combining effective air cleaning systems for volatile organic compounds (VOCs) with particle filtration then by relying solely on ventilation. For such applications, ultraviolet photocatalytic oxidation (UVPCO) systems are being developed for VOC destruction. An experimental evaluation of a UVPCO system is reported. The evaluation was unique in that it employed complex mixtures of VOCs commonly found in office buildings at realistically low concentrations. VOC conversion efficiencies varied over a broad range, usually exceeded 20%, and were as high as {approx}80%. Conversion efficiency generally diminished with increased air flow rate. Significant amounts of formaldehyde and acetaldehyde were produced due to incomplete mineralization. The results indicate that formaldehyde and acetaldehyde production rates may need to be reduced before such UVPCO systems can be deployed safely in occupied buildings.

  1. Classroom HVAC: Improving ventilation and saving energy -- field study plan

    SciTech Connect (OSTI)

    Apte, Michael G.; Faulkner, David; Hodgson, Alfred T.; Sullivan, Douglas P.

    2004-10-14T23:59:59.000Z

    The primary goals of this research effort are to develop, evaluate, and demonstrate a very practical HVAC system for classrooms that consistently provides classrooms (CRs) with the quantity of ventilation in current minimum standards, while saving energy, and reducing HVAC-related noise levels. This research is motivated by the public benefits of energy efficiency, evidence that many CRs are under-ventilated, and public concerns about indoor environmental quality in CRs. This document provides a summary of the detailed plans developed for the field study that will take place in 2005 to evaluate the energy and IAQ performance of a new classroom HVAC technology. The field study will include measurements of HVAC energy use, ventilation rates, and IEQ conditions in 10 classrooms with the new HVAC technology and in six control classrooms with a standard HVAC system. Energy use and many IEQ parameters will be monitored continuously, while other IEQ measurements will be will be performed seasonally. Continuously monitored data will be remotely accessed via a LonWorks network. Instrument calibration plans that vary with the type of instrumentation used are established. Statistical tests will be employed to compare energy use and IEQ conditions with the new and standard HVAC systems. Strengths of this study plan include the collection of real time data for a full school year, the use of high quality instrumentation, the incorporation of many quality control measures, and the extensive collaborations with industry that limit costs to the sponsors.

  2. Measuring Residential Ventilation System Airflows: Part 1 Laboratory

    E-Print Network [OSTI]

    1 Measuring Residential Ventilation System Airflows: Part 1 ­ Laboratory Evaluation of Airflow: residential, mechanical ventilation, measurement, ASHRAE 62.2, flow hood ABSTRACT Building codes increasingly require tighter homes and mechanical ventilation per ASHRAE Standard 62.2. These ventilation flows must

  3. THE MECHANICS OF LUNG TISSUE UNDER HIGH-FREQUENCY VENTILATION

    E-Print Network [OSTI]

    Lewis, Mark

    THE MECHANICS OF LUNG TISSUE UNDER HIGH-FREQUENCY VENTILATION MARKUS R. OWEN AND MARK A. LEWIS SIAM­1761 Abstract. High-frequency ventilation is a radical departure from conventional lung ventilation question concerns ventilator-induced damage to the lung tissue, and a clear protocol for the most effective

  4. THE MECHANICS OF LUNG TISSUE UNDER HIGH-FREQUENCY VENTILATION

    E-Print Network [OSTI]

    THE MECHANICS OF LUNG TISSUE UNDER HIGH-FREQUENCY VENTILATION MARKUS R. OWEN AND MARK A. LEWIS Abstract. High frequency ventilation is a radical departure from conventional lung ventilation question concerns ventilator induced damage to the lung tissue, and a clear protocol for the most effective

  5. Building America Webinar: Multifamily Ventilation Strategies and Compartmentalization Requirements

    Broader source: Energy.gov [DOE]

    The webinar will focus on key challenges in multifamily ventilation and strategies to address these challenges.

  6. RECOMMENDED VENTILATION STRATEGIES FOR ENERGY-EFFICIENT PRODUCTION HOMES

    E-Print Network [OSTI]

    -port exhaust ventilation fan, and that builders offer balanced heat- recovery ventilation to buyersLBNL-40378 UC-000 RECOMMENDED VENTILATION STRATEGIES FOR ENERGY-EFFICIENT PRODUCTION HOMES Judy A of Energy under Contract No. DE-AC03-76SF00098. #12;i Abstract This report evaluates residential ventilation

  7. Evaluation of an Incremental Ventilation Energy Model for Estimating Impacts of Air Sealing and Mechanical Ventilation

    E-Print Network [OSTI]

    Logue, Jennifer M.

    2014-01-01T23:59:59.000Z

    weather files for representative cities within each climatewas modeled in the representative city for each of the sevenclimate zones and representative cities were used: 2A hot/

  8. Evaluation of an Incremental Ventilation Energy Model for Estimating Impacts of Air Sealing and Mechanical Ventilation

    E-Print Network [OSTI]

    Logue, Jennifer M.

    2014-01-01T23:59:59.000Z

    associated change in energy demand of homes. The IVE modelmodels that calculate energy demand by solving a series ofand (b) the change in energy demand resulting in a change in

  9. Building Efficiency and Indoor Air Quality - You Can Have Both

    E-Print Network [OSTI]

    Kettler, G. J.

    1998-01-01T23:59:59.000Z

    Providing ventilation for acceptable indoor air quality per ASHRAE Standard 62-1989 does not require large increases in utility costs. Building efficiency does not have to be sacrificed for a healthy building. The ASHRAE 62- 1989 requirement...

  10. Optimising the Fresh Air Economiser

    E-Print Network [OSTI]

    Biship, R.

    2013-01-01T23:59:59.000Z

    , S., ?Economizers in Air Handling Systems?, CED Engineering Course M01-014, Stony Point New York, 2000. Moser, D., ?Free Cooling: Don?t Let Savings Slip Away?, Portland Energy Conservation Inc., published in Building Operating Management.... New Zealand, Standard NZS 4303:1990, Ventilation for Acceptable Indoor Air Quality, Standards Association of New Zealand, Wellington. Portland Energy Conservation Inc., from Functional Testing Guide on website: (http...

  11. Tunnel ventilation effectiveness in fire scenarios 

    E-Print Network [OSTI]

    Colella, Francesco; Rein, Guillermo; Carvel, Ricky O; Torero, Jose L

    2010-01-01T23:59:59.000Z

    Throughout most of a tunnel network the ventilation behaviour may be approximated with a simple 1D flow model. However, there are some important - but relatively small - regions of the tunnel that require CFD analysis. The multi-scale model...

  12. A Ventilation Index for Tropical Cyclones

    E-Print Network [OSTI]

    Tang, Brian

    An important environmental control of both tropical cyclone intensity and genesis is vertical wind shear. One hypothesized pathway by which vertical shear affects tropical cyclones is midlevel ventilation—or the flux of ...

  13. Performance Assessment of Photovoltaic Attic Ventilator Fans 

    E-Print Network [OSTI]

    Parker, D. S.; Sherwin, J. R.

    2000-01-01T23:59:59.000Z

    has long been identified as a method to abate such heat gains. We present test results from using the photovoltaic (PV) attic ventilator fans in a test home to assess impact on attic and cooling energy performance....

  14. Development of a Residential Integrated Ventilation Controller

    E-Print Network [OSTI]

    Walker, Iain

    2013-01-01T23:59:59.000Z

    and Ventilation Center. Emmerich, S.J, Dols, W.S. , “LoopDA:8 Int. IPBSA Conf. (2003) Emmerich S.J. Nabinger, S. J. “53484. Wallace, L. A. , Emmerich, S. J. , and Howard-Reed,

  15. May 1999 LBNL -42975 ASHRAE'S RESIDENTIAL VENTILATION

    E-Print Network [OSTI]

    May 1999 LBNL - 42975 ASHRAE'S RESIDENTIAL VENTILATION STANDARD: EXEGESIS OF PROPOSED STANDARD 62 standard. 1 Max Sherman is a Senior Scientist at LBNL and the group leader of its Energy Performance

  16. Performance Assessment of Photovoltaic Attic Ventilator Fans

    E-Print Network [OSTI]

    Parker, D. S.; Sherwin, J. R.

    2000-01-01T23:59:59.000Z

    has long been identified as a method to abate such heat gains. We present test results from using the photovoltaic (PV) attic ventilator fans in a test home to assess impact on attic and cooling energy performance....

  17. Disposable colorimetric carbon dioxide detector use as an indicator of a patent airway during noninvasive mask ventilation

    E-Print Network [OSTI]

    Leone, T A; Lange, A; Rich, W; Finer, N N

    2006-01-01T23:59:59.000Z

    During Noninvasive Mask Ventilation Tina A. Leone, Allisonduring bag and mask ventilation and en- courage others toposi- tive pressure ventilation in preterm babies ventilated

  18. Literature review supporting assessment of potential radionuclides in the 291-Z exhaust ventilation

    SciTech Connect (OSTI)

    Mahoney, L.A.; Ballinger, M.Y.; Jette, S.J.; Thomas, L.M. Glissmeyer, J.A. [Pacific Northwest Lab., Richland, WA (United States); Davis, W.E. [Westinghouse Hanford Co., Richland, WA (United States)

    1994-08-01T23:59:59.000Z

    This literature review was prepared to support a study conducted by Pacific Northwest Laboratory to assess the potential deposition and resuspension of radionuclides in the 291-Z ventilation exhaust building located in the 200 West Area of the US Department of Energy`s Hanford Project near Richland, Washington. The filtered ventilation air from three of the facilities at the Plutonium Finishing Plant (PFP) complex are combined together in the 291-Z building before discharge through a common stack. These three facilities contributing filtered exhaust air to the discharge stream are (1) the PFP, also known as the Z-Plant or 234-5Z, (2) the Plutonium Reclamation Facility (PRF or 236-Z), and (3), the Waste Incinerator Building (WIB or 232-Z). The 291-Z building houses the exhaust fans that pull air from the 291-Z central collection plenum and exhausts the air to the stack. Section 2.0 of this report is a description of the physical characteristic of the ventilation system from the High Efficiency Particulate Air (HEPA) filters to the exhaust stack. A description of the processes performed in the facilities that are vented through 291-Z is given in Section 3.0. The description focuses on the chemical and physical forms of potential aerosols given off from the unit operations. A timeline of the operations and events that may have affected the deposition of material in the ventilation system is shown. Aerosol and radiation measurements taken in previous studies are also discussed. Section 4.0 discusses the factors that influence particle deposition and adhesion. Mechanisms of attachment and resuspension are covered with specific attention to the PFP ducts. Conclusions and recommendations are given in Section 5.0.

  19. Outside Air Ventilation Controller - Building America Top Innovation...

    Energy Savers [EERE]

    about this Top Innovation. See an example of this Top Innovation in action. Find more case studies of Building America projects across the country that are implementing outside...

  20. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy

    E-Print Network [OSTI]

    Sidheswaran, Meera

    2010-01-01T23:59:59.000Z

    calcination temperature." Applied Catalysis B-EnvironmentalOXYGEN AVAILABILITY." Applied Catalysis 20(1-2): 15- Benne,ambient temperature." Applied Catalysis B-Environmental 81(

  1. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy

    E-Print Network [OSTI]

    Sidheswaran, Meera

    2010-01-01T23:59:59.000Z

    scrubbed with potassium iodide scrubbers preceding each DNPHWaters Sep-pak Ozone scrubber). The concentration valueusing potassium iodide scrubbers (Waters Sep-pak Ozone

  2. Smart School Symposium Heating Ventilation and Air Conditioning Session

    E-Print Network [OSTI]

    California at Davis, University of

    · The presentation will cover the following topic; Typical school Building Load Profiles Typically HVAC Equipment that we can understand the load profiles as well as all the operating characteristics · For this, ASHRAE and secondary) · Schools have a unique building load profile · They are different than other buildings like

  3. Outside Air Ventilation Controller - Building America Top Innovation |

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2:Introduction toManagementOPAM PolicyOfEnergyOutreach to Multifamily Landlords

  4. Heating, Ventilation, and Air Conditioning Projects | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently20,000 RussianBy: Thomas P. D'Agostino,GlenLearning andDesign inImage of13-Energy

  5. Heating Ventilation and Air Conditioning Efficiency | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy ChinaofSchaefer To:Department of Energy Completing

  6. Heating Ventilation and Air Conditioning Efficiency | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122Commercial602 1,39732on Armed Services U.S.Health, Safety, &ofHeating

  7. Control of the microclimate around the head with opposing jet local ventilation

    E-Print Network [OSTI]

    Liu, Chonghui; Higuchi, Hiroshi; Arens, Edward; Zhang, Hui Ph.D

    2009-01-01T23:59:59.000Z

    of opposing jet local ventilation. AIAA 2009 Region I-NEImpact of a task-ambient ventilation system on perceived airefficiency for personalized ventilation application. Healthy

  8. Created: July, 2014 Laboratory Safety Design Guide Section 3 Laboratory Ventilation

    E-Print Network [OSTI]

    Queitsch, Christine

    Created: July, 2014 Laboratory Safety Design Guide Section 3 ­ Laboratory Ventilation 3-1 Section 3 LABORATORY VENTILATION Contents A. Scope .................................................................................................................3-2 B. General Laboratory Ventilation

  9. Relationship of SBS-symptoms and ventilation system type in office buildings

    E-Print Network [OSTI]

    Seppanen, O.; Fisk, W.J.

    2002-01-01T23:59:59.000Z

    SBS-SYMPTOMS AND VENTILATION SYSTEM TYPE IN OFFICE BUILDINGSSBS-SYMPTOMS AND VENTILATION SYSTEM TYPE IN OFFICE BUILDINGSabout the associations of ventilation system types in office

  10. Procedures and Standards for Residential Ventilation System Commissioning: An Annotated Bibliography

    E-Print Network [OSTI]

    Stratton, J. Chris

    2014-01-01T23:59:59.000Z

    Residential Mechanical Ventilation Systems”. CAN/CSA-F326-of Domestic Ventilation Systems”. International EnergyPassive Stack Ventilation Systems: Design and Installation”.

  11. Infiltration Effects on Residential Pollutant Concentrations for Continuous and Intermittent Mechanical Ventilation Approaches

    E-Print Network [OSTI]

    Sherman, Max

    2010-01-01T23:59:59.000Z

    of whole-house ventilation systems in meeting exposurefor residential ventilation system design is the Americanand operating ventilation systems with variable amounts of

  12. Performance testing of a floor-based, occupant-controlled office ventilation system

    E-Print Network [OSTI]

    Bauman, Fred; Johnston, L.; Zhang, H.; Arens, Edward A

    1991-01-01T23:59:59.000Z

    a room ment ventilation systems." ASHRAE Transactions, Vol.95, Part 2. ence, Ventilation System Performance, 18-21Fountain. 1990. "A ventilation systems in office rooms."

  13. Association of ventilation system type with SBS symptoms in office workers

    E-Print Network [OSTI]

    Seppanen, Olli; Fisk, William J.

    2001-01-01T23:59:59.000Z

    Evaluation of Swedish ventilation systems” Building andP. (1995) “Type of ventilation system in office buildingsEvaluation of ventilation system materials as sources of

  14. Energy and Cost Associated with Ventilating Office Buildings in a Tropical Climate

    E-Print Network [OSTI]

    Rim, Donghyun; Schiavon, Stefano; Nazaroff, William W

    2015-01-01T23:59:59.000Z

    heating and cooling energy demand in Switzer- land. Energyorder: 1) ventilation energy demand; 2) ventilation energythe study. Ventilation energy demand Fig 2A summarizes the

  15. Infiltration as Ventilation: Weather-Induced Dilution

    E-Print Network [OSTI]

    Sherman, Max H.

    2014-01-01T23:59:59.000Z

    Refrigerating and Air Conditioning Engineers. ASHRAERefrigerating and Air Conditioning Engineers. ASTM, StandardRefrigerating and Air-Conditioning Engineers (ASHRAE) is the

  16. Multi-dimensional Meta-analysis for Assessment of Relationships between Asthma Rates and Particulate Air Pollution

    E-Print Network [OSTI]

    J. I. Brand; M. S. Hallbeck; S. M. Ryan

    2001-01-18T23:59:59.000Z

    Multi-dimensional meta-analysis (MDMA) is an innovative technique for investigating complex scientific problems influenced by "external" factors, such as social, medical, economic, political or climatic trends. MDMA extends traditional meta-analysis by identifying significant data from diverse and independent disciplines ("orthogonal dimensions") and incorporating truth tables and non-parametric analysis methods in the interpretation protocol. In this paper, we outline the methodology of MDMA. We then demonstrates how to apply the method to a specific problem: the relationship between asthma and air particulates. The conclusions from the example show that the further reduction of atmospheric particulate levels is not necessarily the answer to the increasing asthma incidence. This example also demonstrates the strength of this method of analysis for complex problems.

  17. Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California: Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure

    E-Print Network [OSTI]

    Mendell, Mark

    2014-01-01T23:59:59.000Z

    EUI) predicted with building energy models created using theusing EPA model ? Health benefits of reduced energy usage (

  18. Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California: Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure

    E-Print Network [OSTI]

    Mendell, Mark

    2014-01-01T23:59:59.000Z

    Achieving IAQ and Energy Conservation Goals with ASHRAEBalancing energy conservation and occupant needs in  500-99-013 Balancing energy conservation and occupant needs

  19. Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California: Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure

    E-Print Network [OSTI]

    Mendell, Mark

    2014-01-01T23:59:59.000Z

    affect IAQ negatively (health + productivity) InappropriateIAQ standards that support occupant comfort, health, productivity, and

  20. Comparison of heating and cooling energy consumption by HVAC system with mixing and displacement air distribution for a restaurant dining area in different climates

    SciTech Connect (OSTI)

    Zhivov, A.M. [International Air Technologies, Inc., Savoy, IL (United States); Rymkevich, A.A. [St. Petersburg Academy of Refrigeration and Food Technology (Russian Federation). Dept. of Refrigeration Machines and Air-Conditioning Systems

    1998-12-31T23:59:59.000Z

    Different ventilation strategies to improve indoor air quality and to reduce HVAC system operating costs in a restaurant with nonsmoking and smoking areas and a bar are discussed in this paper. A generic sitting-type restaurant is used for the analysis. Prototype designs for the restaurant chain with more than 200 restaurants in different US climates were analyzed to collect the information on building envelope, dining area size, heat and contaminant sources and loads, occupancy rates, and current design practices. Four constant air volume HVAC systems wit h a constant and variable (demand-based) outdoor airflow rate, with a mixing and displacement air distribution, were compared in five representative US climates: cold (Minneapolis, MN); Maritime (Seattle, WA); moderate (Albuquerque, NM); hot-dry (Phoenix, AZ); and hot-humid (Miami, FL). For all four compared cases and climatic conditions, heating and cooling consumption by the HVAC system throughout the year-round operation was calculated and operation costs were compared. The analysis shows: Displacement air distribution allows for better indoor air quality in the breathing zone at the same outdoor air supply airflow rate due to contaminant stratification along the room height. The increase in outdoor air supply during the peak hours in Miami and Albuquerque results in an increase of both heating and cooling energy consumption. In other climates, the increase in outdoor air supply results in reduced cooling energy consumption. For the Phoenix, Minneapolis, and Seattle locations, the HVAC system operation with a variable outdoor air supply allows for a decrease in cooling consumption up to 50% and, in some cases, eliminates the use of refrigeration machines. The effect of temperature stratification on HVAC system parameters is the same for all locations; displacement ventilation systems result in decreased cooling energy consumption but increased heating consumption.

  1. Assessment of Energy Savings Potential from the Use of Demand Controlled Ventilation in General Office Spaces in California

    SciTech Connect (OSTI)

    Hong, Tianzhen; Fisk, William

    2010-01-01T23:59:59.000Z

    A prototypical office building meeting the prescriptive requirements of the 2008 California building energy efficiency standards (Title 24) was used in EnergyPlus simulations to calculate the energy savings potential of demand controlled ventilation (DCV) in five typical California climates per three design occupancy densities and two minimum ventilation rates. The assumed minimum ventilation rates in offices without DCV, based on two different measurement methods employed in a large survey, were 38 and 13 L/s per occupant. The results of the life cycle cost analysis show DCV is cost effective for office spaces if the typical minimum ventilation rate without DCV is 38 L/s per person, except at the low design occupancy of 10.8 people per 100 m2 in climate zones 3 (north coast) and 6 (south Coast). DCV was not found to be cost effective if the typical minimum ventilation rate without DCV is 13 L/s per occupant, except at high design occupancy of 21.5 people per 100 m2 in climate zones 14 (desert) and 16 (mountains). Until the large uncertainties about the base case ventilation rates in offices without DCV are reduced, the case for requiring DCV in general office spaces will be a weak case. Under the Title 24 Standards office occupant density of 10.8 people per 100 m2, DCV becomes cost effective when the base case minimum ventilation rate is greater than 42.5, 43.0, 24.0, 19.0, and 18.0 L/s per person for climate zone 3, 6, 12, 14, and 16 respectively.

  2. Particle deposition in ventilation ducts

    E-Print Network [OSTI]

    Sippola, Mark R.

    2002-01-01T23:59:59.000Z

    and An Evaluation of Thermophoretic Deposition Rates C.1of estimated thermophoretic deposition velocities, v th+ ,of estimated thermophoretic deposition velocities, v th+ ,

  3. Computer Simulation of Cooling Effect of Wind Tower on Passively Ventilated Building 

    E-Print Network [OSTI]

    Seryak, J.; Kissock, J. K.

    2002-01-01T23:59:59.000Z

    Traditional buildings are cooled and ventilated by mechanically induced drafts. Natural ventilation aspires to cool and ventilate a building by natural means, such as cross ventilation or wind towers, without mechanical equipment. A simple computer...

  4. MODELING VENTILATION SYSTEM RESPONSE TO FIRE

    SciTech Connect (OSTI)

    Coutts, D

    2007-04-17T23:59:59.000Z

    Fires in facilities containing nuclear material have the potential to transport radioactive contamination throughout buildings and may lead to widespread downwind dispersal threatening both worker and public safety. Development and implementation of control strategies capable of providing adequate protection from fire requires realistic characterization of ventilation system response which, in turn, depends on an understanding of fire development timing and suppression system response. This paper discusses work in which published HEPA filter data was combined with CFAST fire modeling predictions to evaluate protective control strategies for a hypothetical DOE non-reactor nuclear facility. The purpose of this effort was to evaluate when safety significant active ventilation coupled with safety class passive ventilation might be a viable control strategy.

  5. NBSIR 79-1911 Procedures for Testing, Rating,

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    is developed for heat engine-driven air-to-air heat pump systems. The procedures are classified according; heat pump; heating and cooling equipment; heating, ventilating and air conditioning. iii #12 of Engine-Driven Heat Pump Systems B. R. Maxwell NO#QT RM Building Thermal and Service Systems Division

  6. Design of a Natural Ventilation System in the Dunhuang Museum 

    E-Print Network [OSTI]

    Zhang, Y.; Guan, W.

    2006-01-01T23:59:59.000Z

    that also meets architectural standards. Natural ventilation design methods are presented in this paper. A natural ventilation system is designed in the DunHuang museum. Thermal dynamic simulation and CFD simulation were analyzed in the exhibition hall...

  7. Analyzing Ventilation Effects of Different Apartment Styles by CFD

    E-Print Network [OSTI]

    Li, X.; Wang, L.; Ye, Z.

    2006-01-01T23:59:59.000Z

    in different directions have distinct ventilation environments. By compare the velocity fields of each apartment in four directions, results show that the apartment in the east has favorable ventilation effects. There are some disadvantages of other apartments...

  8. Application Study on Combined Ventilation System of Improving IAQ

    E-Print Network [OSTI]

    Hu, S.; Li, G.; Zhang, C.; Ye, B.

    2006-01-01T23:59:59.000Z

    A type of combined ventilating system is put forward in this paper. Through CFD simulation and testing of contaminant concentrations in a prototype residential room, the results demonstrate that the new ventilating system is advantageous...

  9. GASTRIC REFLUX IN MECHANICALLY VENTILATED GASTRIC FED ICU PATIENTS

    E-Print Network [OSTI]

    Schallom, Marilyn

    2013-08-31T23:59:59.000Z

    in ventilated patients is a major cause of ventilator associated pneumonia (VAP). Guidelines that recommend head of bed (HOB) elevation greater than 30? to prevent reflux, aspiration and VAP conflict with guidelines to prevent pressure ulcers which recommend HOB...

  10. Natural ventilation : design for suburban houses in Thailand

    E-Print Network [OSTI]

    Tantasavasdi, Chalermwat, 1971-

    1998-01-01T23:59:59.000Z

    Natural Ventilation is the most effective passive cooling design strategy for architecture in hot and humid climates. In Thailand, natural ventilation has been the most essential element in the vernacular architecture such ...

  11. Study of natural ventilation in buildings with large eddy simulation

    E-Print Network [OSTI]

    Jiang, Yi, 1972-

    2002-01-01T23:59:59.000Z

    With the discovery of many economic, environmental, and health problems in sealed and mechanically ventilated buildings, the concept of natural ventilation has been revived. "Buildings that breathe" have become more and ...

  12. Control of the microclimate around the head with opposing jet local ventilation

    E-Print Network [OSTI]

    Liu, Chonghui; Higuchi, Hiroshi; Arens, Edward; Zhang, Hui Ph.D

    2009-01-01T23:59:59.000Z

    of opposing jet local ventilation. AIAA 2009 Region I-NEHead with Opposing Jet Local Ventilation Chonghui Liu 1,* ,

  13. Indoor Air Quality in 24 California Residences Designed as High-Performance Homes

    SciTech Connect (OSTI)

    Less, Brennan; Mullen, Nasim; Singer, Brett; Walker, Iain

    2015-01-01T23:59:59.000Z

    Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California. Although the mechanically vented homes were six times as airtight as non-mechanically ventilated homes (medians of 1.1 and 6.1 ACH50, n=11 and n=8, respectively), their use of mechanical ventilation systems and possibly window operation meant their median air exchange rates were almost the same (0.30 versus 0.32 hr-1, n=8 and n=8, respectively). Pollutant levels were also similar in vented and unvented homes. These similarities were achieved despite numerous observed faults in complex mechanical ventilation systems. More rigorous commissioning is still recommended. Cooking exhaust systems were used inconsistently and several suffered from design flaws. Failure to follow best practices led to IAQ problems in some cases. Ambient nitrogen dioxide standards were exceeded or nearly so in four homes that either used gas ranges with standing pilots, or in Passive House-style homes that used gas cooking burners without venting range hoods. Homes without active particle filtration had particle count concentrations approximately double those in homes with enhanced filtration. The majority of homes reported using low-emitting materials; consistent with this, formaldehyde levels were approximately half those in conventional, new CA homes built before 2008. Emissions of ultrafine particles (with diameters <100 nm) were dramatically lower on induction electric cooktops, compared with either gas or resistance electric models. These results indicate that high performance homes can achieve acceptable and even exceptional IAQ by providing adequate general mechanical ventilation, using low-emitting materials, providing mechanical particle filtration, incorporating well-designed exhaust ventilation for kitchens and bathrooms, and educating occupants to use the kitchen and bath ventilation.

  14. Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Cooling Season Energy and Moisture Levels

    SciTech Connect (OSTI)

    Parker, D.; Kono, J.; Vieira, R.; Fairey, P.; Sherwin, J.; Withers, C.; Hoak, D.; Beal, D.

    2014-05-01T23:59:59.000Z

    Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

  15. STATE OF CALIFORNIA DEMAND CONTROL VENTILATION SYSTEMS ACCEPTANCE

    E-Print Network [OSTI]

    STATE OF CALIFORNIA DEMAND CONTROL VENTILATION SYSTEMS ACCEPTANCE CEC-MECH-6A (Revised 08/09) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF ACCEPTANCE MECH-6A NA7.5.5 Demand Control Ventilation Systems DEMAND CONTROL VENTILATION SYSTEMS ACCEPTANCE CEC-MECH-6A (Revised 08/09) CALIFORNIA ENERGY COMMISSION

  16. Contribution of Gular Pumping to Lung Ventilation in Monitor

    E-Print Network [OSTI]

    Brainerd, Elizabeth

    Contribution of Gular Pumping to Lung Ventilation in Monitor Lizards Tomasz Owerkowicz,1 * Colleen that lizards are subject to a speed- dependent axial constraint that prevents effective lung ventilation during locomotion, varanids use a positive pressure gular pump to assist lung ventilation. Disabling the gular pump

  17. Care of a cardiac pt on mechanical ventilation

    E-Print Network [OSTI]

    Kay, Mark A.

    Care of a cardiac pt on mechanical ventilation CVICU New Hires Orientation Day 2 Winnie Yung, RN, MN #12;Outline · Physiology of breathing · Terminology · Intubation · Mode of mechanical ventilation· Mode of mechanical ventilation · Nursing care of a vented pt · Nursing care of a vented single

  18. Improved Wireless Performance from Mode Scattering in Ventilation Ducts

    E-Print Network [OSTI]

    Stancil, Daniel D.

    Improved Wireless Performance from Mode Scattering in Ventilation Ducts Benjamin E. Henty, PA 15230. henty@eirp.org and stancil@cmu.edu Abstract Ventilation ducts are a convenient present in a ventilation duct T-junction and note with some surprise that improvement in the performance

  19. Estimating ventilation time scales using overturning stream functions

    E-Print Network [OSTI]

    Döös, Kristofer

    Estimating ventilation time scales using overturning stream functions Bijoy Thompson & Jonas for estimating ventilation time scales from overturning stream functions is proposed. The stream function may describing an ide- alized semi-enclosed ocean basin ventilated through a narrow strait over a sill

  20. Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings

    E-Print Network [OSTI]

    Mountziaris, T. J.

    Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings Tom Rogg REU Student are important considerations in building design. Incorporation of a combination of passive ventilation systems of the National Science Foundation. Research Objectives · To provide proof of concept that a passive ventilation