Powered by Deep Web Technologies
Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Comprehensive air monitoring plan: general monitoring report  

DOE Green Energy (OSTI)

Recommendations are provided for general monitoring of hydrogen sulfide (H/sub 2/S) in ambient air in parts of Colusa, Lake, Mendocino, Napa, and Sonoma counties potentially impacted by emissions from geothermal development projects in the Geysers-Calistoga Known Geothermal Resource Area. Recommendations for types, placement, performance guidelines, and criteria and procedure for triggering establishment and termination of CAMP monitoring equipment were determined after examination of four factors: population location; emission sources; meteorological considerations; and data needs of permitting agencies and applicants. Three alternate financial plans were developed. Locations and equipment for immediate installation are recommended for: two air quality stations in communities where the State ambient air quality standard for H/sub 2/S has been exceeded; three air quality trend stations to monitor progress in reduction of H/sub 2/S emissions; two meteorological observation stations to monitor synoptic wind flow over the area; and one acoustic radar and one rawinsonde station to monitor air inversions which limit the depth of the mixing layer.

Not Available

1980-03-31T23:59:59.000Z

2

NETL: Ambient Monitoring - Steubenville Comprehensive Air Monitoring  

NLE Websites -- All DOE Office Websites (Extended Search)

Steubenville Comprehensive Air Monitoring Project (SCAMP) Steubenville Comprehensive Air Monitoring Project (SCAMP) The National Ambient Air Quality Standards for airborne fine particles (PM2.5) are based on the mass of PM2.5 measured at outdoor monitoring stations; however, most people spend the majority of their time indoors. In order to fully understand the relationship between ambient PM2.5 and human health effects, it is important to define how ambient PM2.5 concentrations and compositions compare to those actually breathed by humans during normal daily activities. The objective of SCAMP is to measure the concentrations of PM2.5 and other potential air pollutants at ambient monitoring stations in and around Steubenville, OH, and relate them to the pollutant concentrations in air that is actually breathed by people living in the area. Steubenville was chosen by DOE for this study because of the ability to integrate its results with those of the UORVP, and also because Steubenville was one of the six cities where correlations between ambient PM2.5 mass and adverse health effects had been noted. These correlations had been cited by EPA as one of the primary justifications for its 1997 ambient PM2.5 standards. Complete characterization of the relationships between ambient PM2.5 and human exposure, including the chemical components of PM2.5 at various locations, will provide a comprehensive database for use in subsequent epidemiological studies, long-range transport studies, and State Implementation Program development. CONSOL Energy is the primary performer of SCAMP, and will provide the necessary coordination and data integration between the various components of the study.

3

Alpha-environmental continuous air monitor inlet  

DOE Patents (OSTI)

A wind deceleration and protective shroud that provides representative samples of ambient aerosols to an environmental continuous air monitor (ECAM) has a cylindrical enclosure mounted to an input on the continuous air monitor, the cylindrical enclosure having shrouded nozzles located radially about its periphery. Ambient air flows, often along with rainwater flows into the nozzles in a sampling flow generated by a pump in the continuous air monitor. The sampling flow of air creates a cyclonic flow in the enclosure that flows up through the cylindrical enclosure until the flow of air reaches the top of the cylindrical enclosure and then is directed downward to the continuous air monitor. A sloped platform located inside the cylindrical enclosure supports the nozzles and causes any moisture entering through the nozzle to drain out through the nozzles.

Rodgers, John C. (Santa Fe, NM)

2003-01-01T23:59:59.000Z

4

Renewable Energy Monitoring Evaluation Terms of Reference | Open Energy  

Open Energy Info (EERE)

Renewable Energy Monitoring Evaluation Terms of Reference Renewable Energy Monitoring Evaluation Terms of Reference Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Renewable Energy Monitoring Evaluation Terms of Reference Agency/Company /Organization: World Bank Sector: Energy Focus Area: Renewable Energy Topics: Policies/deployment programs Website: web.worldbank.org/WBSITE/EXTERNAL/TOPICS/EXTENERGY2/EXTRENENERGYTK/0,, References: Renewable Energy Monitoring Evaluation Terms of Reference[1] Resources Design of a Monitoring and Evaluation Plan Audit of Solar Home Systems Project Mid-term Review Panel for Solar Home Systems Project Socio-Economic Survey of the Photovoltaic Pilot Project References ↑ "Renewable Energy Monitoring Evaluation Terms of Reference" Retrieved from "http://en.openei.org/w/index.php?title=Renewable_Energy_Monitoring_Evaluation_Terms_of_Reference&oldid=329154"

5

Zone based indoor mobile air pollution monitoring  

Science Conference Proceedings (OSTI)

Pollution is one of the main problems that humans are suffering from. Moreover air pollution is one of the hardest to escape. Although human spend most of their time indoor, most of the previous pollution monitoring studies focused on outdoor air monitoring. ... Keywords: indoor pollution, mobile sensing, nfc

Noura Alhakbani, Eiman Kanjo

2013-09-01T23:59:59.000Z

6

Room air monitor for radioactive aerosols  

DOE Patents (OSTI)

A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-pre The U.S. Government has rights in this invention pursuant to Contract No. DE-AC04-76DP03533 between the Department of Energy and Rockwell International Corporation.

Balmer, David K. (Broomfield, CO); Tyree, William H. (Boulder, CO)

1989-04-11T23:59:59.000Z

7

Room air monitor for radioactive aerosols  

DOE Patents (OSTI)

A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-preamplifier combination. 2 figs.

Balmer, D.K.; Tyree, W.H.

1987-03-23T23:59:59.000Z

8

Committee on Monitoring Research Terms of Reference  

E-Print Network (OSTI)

The Council is, therefore, developing an overall proposal for monitoring the progress of research within NOAA. The four key elements of the new monitoring strategy are: To link research milestones with activities in the Program Operating Plans of the goal and program teams, the Annual Operating Plans of the Line Offices and the performance objectives of the NOAA strategic plan; To regularly evaluate the quality, relevance, and value of NOAA’s research, both internally in NOAA, and by external review teams; To use a NOAA-wide database to track research accomplishments, and the outcomes in society that result from them; To track the financial reporting of research activities across the Agency. Because monitoring of research in NOAA is proposed to be systematic and ongoing, it is appropriate to establish a permanent Committee of the Research Council for that purpose. The NOAA Executive Panel endorsed such a Committee. Definitions Research and development are defined as:

unknown authors

2007-01-01T23:59:59.000Z

9

Solar Powered Radioactive Air Monitoring Stations  

SciTech Connect

Environmental monitoring of ambient air for radioactive material is required as stipulated in the PNNL Site radioactive air license. Sampling ambient air at identified preferred locations could not be initially accomplished because utilities were not readily available. Therefore, solar powered environmental monitoring systems were considered as a possible option. PNNL purchased two 24-V DC solar powered environmental monitoring systems which consisted of solar panels, battery banks, and sampling units. During an approximate four month performance evaluation period, the solar stations operated satisfactorily at an on-site test location. They were subsequently relocated to their preferred locations in June 2012 where they continue to function adequately under the conditions found in Richland, Washington.

Barnett, J. M.; Bisping, Lynn E.; Gervais, Todd L.

2013-10-30T23:59:59.000Z

10

Tritium Room Air Monitor Operating Experience Review  

SciTech Connect

Monitoring the breathing air in tritium facility rooms for airborne tritium is a radiological safety requirement and a best practice for personnel safety. Besides audible alarms for room evacuation, these monitors often send signals for process shutdown, ventilation isolation, and cleanup system actuation to mitigate releases and prevent tritium spread to the environment. Therefore, these monitors are important not only to personnel safety but also to public safety and environmental protection. This paper presents an operating experience review of tritium monitor performance on demand during small (1 mCi to 1 Ci) operational releases, and intentional airborne inroom tritium release tests. The tritium tests provide monitor operation data to allow calculation of a statistical estimate for the reliability of monitors annunciating in actual tritium gas airborne release situations. The data show a failure to operate rate of 3.5E-06/monitor-hr with an upper bound of 4.7E-06, a failure to alarm on demand rate of 1.4E-02/demand with an upper bound of 4.4E-02, and a spurious alarm rate of 0.1 to 0.2/monitor-yr.

L. C. Cadwallader; B. J. Denny

2008-09-01T23:59:59.000Z

11

Monitoring Air Fluoride (F-) Concentration around ALUAR Smelter in ...  

Science Conference Proceedings (OSTI)

About this Abstract. Meeting, 2011 TMS Annual Meeting & Exhibition. Symposium , Aluminum Reduction Technology. Presentation Title, Monitoring Air Fluoride ...

12

Continuous Air Monitor Operating Experience Review  

Science Conference Proceedings (OSTI)

Continuous air monitors (CAMs) are used to sense radioactive particulates in room air of nuclear facilities. CAMs alert personnel of potential inhalation exposures to radionuclides and can also actuate room ventilation isolation for public and environmental protection. This paper presents the results of a CAM operating experience review of the DOE Occurrence Reporting and Processing System (ORPS) database from the past 18 years. Regulations regarding these monitors are briefly reviewed. CAM location selection and operation are briefly discussed. Operating experiences reported by the U.S. Department of Energy and in other literature sources were reviewed to determine the strengths and weaknesses of these monitors. Power losses, human errors, and mechanical issues cause the majority of failures. The average “all modes” failure rate is 2.65E-05/hr. Repair time estimates vary from an average repair time of 9 hours (with spare parts on hand) to 252 hours (without spare parts on hand). These data should support the use of CAMs in any nuclear facility, including the National Ignition Facility and the international ITER experiment.

L. C. Cadwallader; S. A. Bruyere

2008-09-01T23:59:59.000Z

13

Continuous air monitor filter changeout apparatus  

DOE Patents (OSTI)

An apparatus and corresponding method for automatically changing out a filter cartridge in a continuous air monitor. The apparatus includes: a first container sized to hold filter cartridge replacements; a second container sized to hold used filter cartridges; a transport insert connectively attached to the first and second containers; a shuttle block, sized to hold the filter cartridges that is located within the transport insert; a transport driver mechanism means used to supply a motive force to move the shuttle block within the transport insert; and, a control means for operating the transport driver mechanism.

Rodgers, John C. (Santa Fe, NM)

2008-07-15T23:59:59.000Z

14

Abatement of Air Pollution: Air Pollution Control Equipment and Monitoring Equipment Operation (Connecticut)  

Energy.gov (U.S. Department of Energy (DOE))

These regulations contain instructions for the operation and monitoring of air pollution control equipment, as well as comments on procedures in the event of equipment breakdown, failure, and...

15

Performance assessment on continuous air monitors under real operating conditions  

Science Conference Proceedings (OSTI)

In the nuclear industry, workers may be exposed to artificial radioactive aerosols. These aerosols are generally composed of particles with a diameter measuring between 0.1 {mu}m and 10 {mu}m. To protect workers in nuclear facilities, monitors that continuously measure radioactivity in the air are used. The main function of the monitor is to provide real-time measurement of activity concentration. Measurement of aerosol activity concentration can be affected by a number of factors specific to the aerosols and the instrument. The first part of the article will present the general operating principles of continuous air monitors (CAMs) and inherent measurement difficulties, as well as the main standard tests. The second section describes the experimental ICARE facility The ICARE facility generates standard artificial and natural radioactive aerosols for calibrating continuous air monitors under real operating conditions. (authors)

Monsanglant-Louvet, C.; Liatimi, N.; Gensdarmes, F. [Inst. of Radioprotection and Nuclear Safety- IRSN, Saclay (France)

2011-07-01T23:59:59.000Z

16

Concepts for Environmental Radioactive Air Sampling and Monitoring  

SciTech Connect

Environmental radioactive air sampling and monitoring is becoming increasingly important as regulatory agencies promulgate requirements for the measurement and quantification of radioactive contaminants. While researchers add to the growing body of knowledge in this area, events such as earthquakes and tsunamis demonstrate how nuclear systems can be compromised. The result is the need for adequate environmental monitoring to assure the public of their safety and to assist emergency workers in their response. Two forms of radioactive air monitoring include direct effluent measurements and environmental surveillance. This chapter presents basic concepts for direct effluent sampling and environmental surveillance of radioactive air emissions, including information on establishing the basis for sampling and/or monitoring, criteria for sampling media and sample analysis, reporting and compliance, and continual improvement.

Barnett, J. M.

2011-11-04T23:59:59.000Z

17

Air Pollution Background Monitoring over the Former Soviet Union: Fifteen Years of Observations  

Science Conference Proceedings (OSTI)

Regular air pollution observations in background areas over the former Soviet Union (FSU) were started in the 1980s. The air background monitoring network consisted of 16 stations working under the Integrated Monitoring (IM) Program. Several air ...

Sergey G. Paramonov

1998-10-01T23:59:59.000Z

18

Air Monitoring of Emissions from the Fukushima Daiichi Reactor  

SciTech Connect

In response to the disasters in Japan on March 11, 2011, and the subsequent emissions from Fukushima-Daiichi, we monitored the air near Los Alamos using four air-monitoring systems: the standard AIRNET samplers, the standard rad-NESHAP samplers, the NEWNET system, and high-volume air samplers. Each of these systems has advantages and disadvantages. In combination, they provide a comprehensive set of measurements of airborne radionuclides near Los Alamos during the weeks following March 11. We report air-monitoring measurements of the fission products released from the Fukushima-Daiichi nuclear-power-plant accident in 2011. Clear gamma-spectrometry peaks were observed from Cs-134, Cs-136, Cs-137, I-131, I132, Te-132, and Te-129m. These data, together with measurements of other radionuclides, are adequate for an assessment and assure us that radionuclides from Fukushima Daiichi did not present a threat to human health at or near Los Alamos. The data demonstrate the capabilities of the Los Alamos air-monitoring systems.

McNaughton, Michael [Los Alamos National Laboratory; Allen, Shannon P. [Los Alamos National Laboratory; Archuleta, Debra C. [Los Alamos National Laboratory; Brock, Burgandy [Los Alamos National Laboratory; Coronado, Melissa A. [Los Alamos National Laboratory; Dewart, Jean M. [Los Alamos National Laboratory; Eisele, William F. Jr. [Los Alamos National Laboratory; Fuehne, David P. [Los Alamos National Laboratory; Gadd, Milan S. [Los Alamos National Laboratory; Green, Andrew A. [Los Alamos National Laboratory; Lujan, Joan J. [Los Alamos National Laboratory; MacDonell, Carolyn [Los Alamos National Laboratory; Whicker, Jeffrey J. [Los Alamos National Laboratory

2012-06-12T23:59:59.000Z

19

Monitoring radioactive xenon gas in room air using activated charcoal  

SciTech Connect

A method for monitoring room air for radioactive xenon gas is described. It uses activated charcoal vials, a vacuum source and a well-type scintillation counter. The method may be adapted for detection and identification of any radioactive gas excluding those with ultra-short half-lives. Sampling room air during xenon-133 ({sup 133}Xe) ventilation lung studies was performed using this technique. The results show that low concentrations of {sup 133}Xe in room air can be reliably detected and that staff exposure to {sup 133}Xe at this institution was within ICRP recommendations.

Langford, J.; Thompson, G. (Princess Margaret Hospital for Children, Perth (Australia) Sir Charles Gairdner Hospital, Perth (Australia))

1990-03-01T23:59:59.000Z

20

Flexible in-lined reference monitor certification: challenges and future directions  

Science Conference Proceedings (OSTI)

Over the last few years, in-lined reference monitors (IRM's) have gained much popularity as successful security enforcement mechanisms. Aspect-oriented programming (AOP) provides one elegant paradigm for implementing IRM frameworks. There is a ... Keywords: aspect-oriented programming, in-lined reference monitors, runtime verification, static verification

Meera Sridhar; Kevin W. Hamlen

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

References  

NLE Websites -- All DOE Office Websites (Extended Search)

Analysis Analysis Analysis - Home Analytical Dashboards Computerized Accident Incident Reporting and Recordkeeping System (CAIRS) Corporate Safety Analysis Trends Daily Occurrence Reports Electrical Safety Occurrences Final Occurrence Reports Access System Login Lessons Learned and Best Practices Occurrence Reporting and Processing System (ORPS) Operating Experience Committee Operating Experience Level 1, 2, and 3 Documents Operating Experience Summaries Radiation Exposure Monitoring Systems (REMS) Safety Bulletins Safety and Health Alerts Safety Basis Information System (SBIS) Suspect/Counterfeit Items and Defective Items (SCI/DI) References HSS Logo References DOE O 210.2A, DOE Corporate Operating Experience Program (Apr 08, 2011) DOE O 210.2 Crosswalk DOE O 231.1B, Environment, Safety and Health Reporting (Jun 27, 2011)

22

News and Update: Sensors Continually Monitor Water and Air Quality  

Science Conference Proceedings (OSTI)

An Initial Microstructural Analysis of A36 Steel from WTC Building 7 by J.R. Barnett, R.R. ... a system of sensors developed by the U.S. Department of Energy's Sandia ... The system is designed to continually monitor water or air, in- situ, so sample ... to develop a program to train water utilities to assess system vulnerabilities.

23

NETL: News Release - Energy Department Expands Air Monitoring Efforts to  

NLE Websites -- All DOE Office Websites (Extended Search)

September 11, 2000 September 11, 2000 Energy Department Expands Air Monitoring Efforts to Deep South The Energy Department is expanding its efforts to collect data on microscopic airborne particles to the deep South. The department will award Southern Research Institute (SRI), Birmingham, AL, a $750,000 contract to augment an air monitoring station in Alabama with new capabilities to study fine particulate matter called PM2.5. The term stands for particulate matter with a diameter less than 2.5 micrometers, or about 1/30th the width of a human hair. The effort is intended to assist the Environmental Protection Agency (EPA), state agencies and the energy industry in gauging the level and sources of the tiny particles which are now regulated under new federal air quality standards.

24

Automatic electrochemical ambient air monitor for chloride and chlorine  

DOE Patents (OSTI)

An electrochemical monitoring system has been provided for determining chloride and chlorine in air at levels of from about 10-1000 parts per billion. The chloride is determined by oxidation to chlorine followed by reduction to chloride in a closed system. Chlorine is determined by direct reduction at a platinum electrode in 6 M H.sub.2 SO.sub.4 electrolyte. A fully automated system is utilized to (1) acquire and store a value corresponding to electrolyte-containing impurities, (2) subtract this value from that obtained in the presence of air, (3) generate coulometrically a standard sample of chlorine mixed with air sample, and determine it as chlorine and/or chloride, and (4) calculate, display, and store for permanent record the ratio of the signal obtained from the air sample and that obtained with the standard.

Mueller, Theodore R. (Oak Ridge, TN)

1976-07-13T23:59:59.000Z

25

Calibration of Nondispersive Infrared CO2 Analyzers with CO2-in-Air Reference Gases  

Science Conference Proceedings (OSTI)

A set of eight CO2-in-air secondary standard calibration gases has been established by NOAA/Geophysical Monitoring for Climatic Change (GMCC) for use in its global CO2 monitoring program. Use of these gases obviates the need for pressure ...

W. D. Komhyr; T. B. Harris; L. S. Waterman

1985-03-01T23:59:59.000Z

26

ENHANCEMENT OF ENVIRONMENTAL SAMPLING THROUGH AN IMPROVED AIR MONITORING TECHNIQUE  

SciTech Connect

Environmental sampling (ES) is a key component of International Atomic Energy Agency (IAEA) safeguarding approaches throughout the world. Performance of ES (e.g. air, water, vegetation, sediments, soil and biota) supports the IAEAs mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a State and has been available since the introduction of safeguards strengthening measures approved by the IAEA Board of Governors (1992-1997). A recent step-change improvement in the gathering and analysis of air samples at uranium/plutonium bulk handling facilities is an important addition to the international nuclear safeguards inspector's toolkit. Utilizing commonly used equipment throughout the IAEA network of analytical laboratories for particle analysis, researchers are developing the next generation of ES equipment for air grab and constant samples. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) silicon substrate has been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. The new collection equipment will allow IAEA nuclear safeguards inspectors to develop enhanced safeguarding approaches for complicated facilities. This paper will explore the use of air monitoring to establish a baseline environmental signature of a particular facility that could be used for comparison of consistencies in declared operations. The implementation of air monitoring will be contrasted against the use of smear ES when used during unannounced inspections, design information verification, limited frequency unannounced access, and complementary access visits at bulk handling facilities. Technical aspects of the air monitoring device and the analysis of its environmental samples will demonstrate the essential parameters required for successful application of the system.

Hanks, D.

2010-06-07T23:59:59.000Z

27

NETL: Ambient Monitoring - Air Quality Database and Analytical Tool  

NLE Websites -- All DOE Office Websites (Extended Search)

Database and Analytical Tool for Air Quality in the Upper Ohio River Valley Database and Analytical Tool for Air Quality in the Upper Ohio River Valley Advanced Technology Systems, Inc. with Ohio University and Texas A&M University - Kingsville as subcontractors, will develop a state-of-the-art, scalable and robust computer application for NETL to manage the extensive data sets resulting from the DOE-sponsored ambient air monitoring programs in the upper Ohio River valley region. Efforts will be made to include, to the greatest extent possible, ambient air data collected by other agencies in the upper Ohio River valley region, such as U.S. EPA, Pennsylvania Department of Environmental Protection (PA-DEP), West Virginia Division of Environmental Protection (WV-DEP), Ohio EPA, and the Allegheny County Health Department (ACHD). Although emphasis will be placed on data collected in the upper Ohio River valley region, the computer application developed under this Agreement will be designed, to the greatest extent possible, to access data collected at NETL-sponsored ambient air monitoring sites outside the region, such as sites operated by the Tennessee Valley Authority in the Great Smoky Mountains (under DOE Interagency Agreement DE-AI26-98FT40406) and by Southern Research Institute in North Birmingham, AL (under DOE Cooperative Agreement DE-FC26-00NT40770). The data base and analytical tool development effort will also be coordinated, to the greatest extent possible, with similar tools being developed for use by U.S. EPA. This will ensure that the database and analytical tools produced under this Agreement will be readily accessible to a wide variety of stakeholders.

28

Calculation of SY tank annulus continuous air monitor readings after postulated leak scenarios  

Science Conference Proceedings (OSTI)

The objective of this work was to determine whether or not a continuous air monitor (CAM) monitoring the annulus of one of the SY Tanks would be expected to alarm after three postulated leak scenarios. Using data and references provided by Lockheed Martin`s Tank Farm personnel, estimated CAM readings were calculated at specific times after the postulated scenarios might have occurred. Potential CAM readings above background at different times were calculated for the following leak scenarios: Leak rate of 0.01 gal/min; Leak rate of 0.03 gal/min (best estimate of the maximum probable leak rate from a single-shell tank); and Leak of 73 gal (equivalent to a {1/4}-in. leak on the floor of the annulus). The equation used to make the calculations along with descriptions and/or explanations of the terms are included, as is a list of the assumptions and/or values used for the calculations.

Kenoyer, J.L.

1998-08-01T23:59:59.000Z

29

Reference Manual for On-Line Monitoring of Water Chemistry and Corrosion: 1998 Update  

Science Conference Proceedings (OSTI)

Corrosion in steam generating plants is reportedly responsible for over $6 billion each year in additional operating, maintenance, and replacement power costs. Consequently, the utility industry constantly seeks cost-effective methods of avoiding, controlling, and monitoring corrosion. Information in this updated reference manual should help utilities select the most appropriate instrumentation for on-line monitoring of water chemistry and corrosion in power plant systems.

1999-05-05T23:59:59.000Z

30

A rugged continuous air monitor for sampling radionuclides  

E-Print Network (OSTI)

A new rugged continuous air monitor (CAM) for sampling radionuclide has been developed. The sampler was designed for analyzing aerosols from occupied environments of laboratories and samples extracted from stacks and ducts. Experiments were conducted to characterize the collection efficiency of the aerosol sampler system and to characterize the uniformity of particulate deposition on the filter surface as affected by variations in particle size and sampler flow rates. An experimental parametric analysis was conducted to determine the best internal geometric flow configuration, in order to achieve optimum aerosol collection. The results showed that at a flow rate of 56.6 L/min, 90% of 10 []m aerodynamic diameter (AD) aerosol particles penetrated through the sampler. The 10% loss was attributed to particle impaction at the location where the aerosol stream is turned from the vertical direction and then enters a 4 mm gap between a sampler filter and a planar detector, both of which are horizontally oriented. The cut point for the sampler was 20 []m AD. Uniformity of aerosol collection on the filter, as characterized by the coefficient of variation of the areal density deposits, was less than 10% for 10 []m AD aerosol particles. The sampler sealing integrity with respect to air leaks was tested by placing the sampler in a pressurized container and operating the sampler with the pressure in the container higher than that in the sampler for in-leakage, and with the pressure in the container less than that in the sampler for out-leakage. The pressure inside the container did not exceed 10 inches of water. For in-leakage tests, sulfur hexafluoride (SF?) was diluted with air and released into the container, external to the sampler. The ratio of the SF? concentration in the sampler to the SF? concentration in the container was calculated to characterize the integrity of the sampler system. For pressure differences of 5 and 10 inches of water, the in-leakage was 0.03% and 0.02%, respectively. The same procedure was repeated for out-leakage except that the diluted SF? was released into the sampler. The leakage results for this procedure were 0.04% and 0.02% for pressure differences of 5 and 10 inches of water, respectively.

Martinez, Joseph Thaddeus

2002-01-01T23:59:59.000Z

31

Distributed GIS for Monitoring and Modeling Urban Air Quality  

E-Print Network (OSTI)

The progress of technology has made the measurement of air quality and the simulation of complex air pollution models both feasible and cost-effective. However, there is a long way to go in terms of facilitating widespread ...

Yeang, Chen-Hsiang, 1969-

32

A Remote-Sensing Method of Selecting Reference Stations for Evaluating Urbanization Effect on Surface Air Temperature Trends  

Science Conference Proceedings (OSTI)

In the global lands, the bias of urbanization effects still exits in the surface air temperature series of many city weather stations to a certain extent. Reliable reference climate stations need to be selected for the detection and correction of ...

Yuyu Ren; Guoyu Ren

2011-07-01T23:59:59.000Z

33

REFERENCES  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

205.1B 205.1B Approved 05-16-2011 Page 1 REFERENCES 1. INTRODUCTION 2. . Includes a list of sources cited in the directive and additional information sources to assist in implementing DOE Order 205.1B, Cyber Security Program. FEDERAL LAWS AND REGULATIONS a. Public Law (P.L.) 93-579, Privacy Act of 1974, as amended [Title 5 United States Code (U.S.C.) Section 552a]. . b. P.L. 104-106, Division E, Clinger Cohen Act (CCA) (formerly Information Technology Management Reform Act of 1996. c. P.L. 106-65, "National Defense Authorization Act [Section 3212(d)], enacted October 1999. d. P.L. 107-347, Title III, Federal Information Security Management Act of 2002 (FISMA), enacted December 2002. 3. OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULARS. Located at http://www.whitehouse.gov/omb/circulars_default/.

34

Real-Time In-Situ Water (& Air) Field Monitor  

2 Managed by UT-Battelle Presentation_namefor the U.S. Department of Energy The Problem: Environmental impact of VOCs and high cost of monitoring

35

Monitoring System Used to Optimize Compressed Air System Efficiency, Cut Costs  

E-Print Network (OSTI)

In 1994, Thomson Consumer Electronics (RCA), an international manufacturer of electronics equipment purchased a UtillTRACK® Monitoring System for a plant in Indianapolis, Indiana. The system monitored gas and electric meters, substations, main feeders, and major equipment and systems including compressed air. For the compressed air system, monitored data included compressor amps, electrical demand and consumption, pressure and airflow. The resulting UtiliTRACK® reports and graphs showed a significant variation in system efficiency depending upon the demand for air (day of week, time of day, production schedule) and which compressor or compressors were operating. By working with the boiler plant operators and making minor modifications to the existing compressor controls, the operating sequence was modified to maintain high system efficiency under all operating conditions. Monitored data after the changes were made showed a 20% reduction in compressed air system operating costs.

Holmes, W. A.

1998-04-01T23:59:59.000Z

36

Technical Basis for Work Place Air Monitoring for the Plutonium Finishing Plan (PFP)  

SciTech Connect

This document establishes the basis for the Plutonium Finishing Plant's (PFP) work place air monitoring program in accordance with the following requirements: Title 10, Code of Federal Regulations (CFR), Part 835 ''Occupational Radiation Protection''; Hanford Site Radiological Control Manual (HSRCM-1); HNF-PRO-33 1, Work Place Air Monitoring; WHC-SD-CP-SAR-021, Plutonium Finishing Plant Final Safety Analysis Report; and Applicable recognized national standards invoked by DOE Orders and Policies.

JONES, R.A.

1999-10-06T23:59:59.000Z

37

MAQS: a personalized mobile sensing system for indoor air quality monitoring  

Science Conference Proceedings (OSTI)

Most people spend more than 90% of their time indoors; indoor air quality (IAQ) influences human health, safety, productivity, and comfort. This paper describes MAQS, a personalized mobile sensing system for IAQ monitoring. In contrast with existing ... Keywords: air quality sensing, location based service, smartphone

Yifei Jiang; Kun Li; Lei Tian; Ricardo Piedrahita; Xiang Yun; Omkar Mansata; Qin Lv; Robert P. Dick; Michael Hannigan; Li Shang

2011-09-01T23:59:59.000Z

38

Technical basis and evaluation criteria for an air sampling/monitoring program  

Science Conference Proceedings (OSTI)

Air sampling and monitoring programs at DOE facilities need to be reviewed in light of revised requirements and guidance found in, for example, DOE Order 5480.6 (RadCon Manual). Accordingly, the Oak Ridge National Laboratory (ORNL) air monitoring program is being revised and placed on a sound technical basis. A draft technical basis document has been written to establish placement criteria for instruments and to guide the ``retrospective sampling or real-time monitoring`` decision. Facility evaluations are being used to document air sampling/monitoring needs, and instruments are being evaluated in light of these needs. The steps used to develop this program and the technical basis for instrument placement are described.

Gregory, D.C.; Bryan, W.L.; Falter, K.G.

1993-06-01T23:59:59.000Z

39

Air Pollution Control Regulations: No. 6- Continuous Emissions Monitors and Opacity Monitors (Rhode Island)  

Energy.gov (U.S. Department of Energy (DOE))

Stationary sources, including fossil fuel fired steam or hot water generating units, may be required to install and operate a continuous emissions monitoring system equipped with an opacity monitor...

40

Dynamic Control of Lab Air Change Rates using Multiplexed IEQ Monitoring  

NLE Websites -- All DOE Office Websites (Extended Search)

Dynamic Control of Lab Air Change Rates using Multiplexed IEQ Monitoring Dynamic Control of Lab Air Change Rates using Multiplexed IEQ Monitoring Speaker(s): Gordon P. Sharp Date: October 14, 2005 - 12:00pm Location: Bldg. 90 Many aspects of a lab are monitored today in real time such as HVAC equipment operation and lab airflow quantities. However, the quality of lab room airflow or more specifically, the indoor environmental quality (IEQ) performance of a lab, beyond just temperature or perhaps humidity, is rarely monitored due to sensor cost and calibration issues. This is unfortunate, since detailed IEQ monitoring data can be used to substantially reduce lab energy consumption, increase lab safety and with some additional analysis, this data can be used to perform effective continuous commissioning. This presentation discusses a new type of real

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Analysis of historical residential air-conditioning equipment sizing using monitored data  

SciTech Connect

Monitored data were analyzed to determine whether residential air conditioners in the Pacific Northwest historically have been sized properly to meet or slightly exceed actual cooling requirements. Oversizing air-conditioning equipment results in a loss of efficiency because of increased cycling and also lowers humidity control. On the other hand, the penalty of undersizing air-conditioning equipment may be some loss of comfort during extremely hot weather. The monitored data consist of hourly space-conditioning electrical energy use and internal air temperature data collected during the past 7 years from 75 residences in the Pacific Northwest. These residences are equipped with central air conditioners or heat pumps. The periods with the highest cooling energy use were analyzed for each site. A standard industry sizing methodology was used for each site to determine a sizing estimate. Both the sizing recommendation based on Manual J and peak monitored loads are compared to the capacity of the installed equipment for each site to study how the actual capacity differed from both the estimate of proper sizing and from actual demands. Characteristics of the maximum cooling loads are analyzed here to determine which conditions put the highest demand on the air conditioner. Specifically, internal air temperature data are used to determine when the highest cooling loads occur, at constant thermostat settings or when the thermostat was set down. This analysis of monitored data also provides insight into the extent that occupant comfort may be affected by undersizing air conditioners. The findings of this research indicate that cooling equipment historically has often but not always been oversized beyond industry-recommended levels. However, some occupants in homes with undersized, properly sized, and, in rare occasions, even oversized cooling equipment appear to suffer because the cooling equipment cannot always provide adequate cooling. Key findings are summarized.

Lucas, R.G.

1993-02-01T23:59:59.000Z

42

Environmental continuous air monitor inlet with combined preseparator and virtual impactor  

DOE Patents (OSTI)

An inlet for an environmental air monitor is described wherein a pre-separator interfaces with ambient environment air and removes debris and insects commonly associated with high wind outdoors and a deflector plate in communication with incoming air from the pre-separator stage, that directs the air radially and downward uniformly into a plurality of accelerator jets located in a manifold of a virtual impactor, the manifold being cylindrical and having a top, a base, and a wall, with the plurality of accelerator jets being located in the top of the manifold and receiving the directed air and accelerating directed air, thereby creating jets of air penetrating into the manifold, where a major flow is deflected to the walls of the manifold and extracted through ports in the walls. A plurality of receiver nozzles are located in the base of the manifold coaxial with the accelerator jets, and a plurality of matching flow restrictor elements are located in the plurality of receiver nozzles for balancing and equalizing the total minor flow among all the plurality of receiver nozzles, through which a lower, fractional flow extracts large particle constituents of the air for collection on a sample filter after passing through the plurality of receiver nozzles and the plurality of matching flow restrictor elements.

Rodgers, John C. (Santa Fe, NM)

2007-06-19T23:59:59.000Z

43

ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES  

SciTech Connect

Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear ES when used during unannounced inspections, design information verification, limited frequency unannounced access, and complementary access visits at bulk handling facilities. Analysis of technical features required for tamper indication and resistance will demonstrate the viability of successful application of the system in taking ES within a bulk handling location. Further exploration of putting this technology into practice is planned to include mapping uranium enrichment facilities for the identification of optimal for installation of air monitoring devices.

Sexton, L.; Hanks, D.; Degange, J.; Brant, H.; Hall, G.; Cable-Dunlap, P.; Anderson, B.

2011-06-07T23:59:59.000Z

44

Reference Upper-Air Observations for Climate: Rationale, Progress, and Plans  

Science Conference Proceedings (OSTI)

While the global upper-air observing network has provided useful observations for operational weather forecasting for decades, its measurements lack the accuracy and long-term continuity needed for understanding climate change. Consequently, the ...

Dian J. Seidel; Franz H. Berger; Franz Immler; Michael Sommer; Holger Vömel; Howard J. Diamond; John Dykema; David Goodrich; William Murray; Thomas Peterson; Douglas Sisterson; Peter Thorne; Junhong Wang

2009-03-01T23:59:59.000Z

45

Reference Handbook for Site-Specific Assessment of Subsurface Vapor Intrusion to Indoor Air  

Science Conference Proceedings (OSTI)

Subsurface vapor intrusion is only one of several possible sources for volatile and semi-volatile chemicals in indoor air. This report provides guidance on the site-specific assessment of the significance of subsurface vapor intrusion into indoor air. Topics covered include theoretical considerations, sampling and analysis considerations, recommended strategies and procedures, interpretive tools, mitigation measures, and suggestions for future research. This document reflects a comprehensive understandin...

2005-03-28T23:59:59.000Z

46

Data Quality Objectives Supporting Radiological Air Emissions Monitoring for the PNNL Site  

Science Conference Proceedings (OSTI)

Pacific Northwest National Laboratory (PNNL) is in the process of developing a radiological air monitoring program for the PNNL Site that is distinct from that of the nearby Hanford Site. The original DQO (PNNL-19427) considered radiological emissions at the PNNL Site from Physical Sciences Facility (PSF) major emissions units. This first revision considers PNNL Site changes subsequent to the implementation of the original DQO. A team was established to determine how the PNNL Site changes would continue to meet federal regulations and address guidelines developed to monitor air emissions and estimate offsite impacts of radioactive material operations. The result is an updated program to monitor the impact to the public from the PNNL Site. The team used the emission unit operation parameters and local meteorological data as well as information from the PSF Potential-to-Emit documentation and Notices of Construction submitted to the Washington State Department of Health (WDOH). The locations where environmental monitoring stations would most successfully characterize the maximum offsite impacts of PNNL Site emissions from the three PSF buildings with major emission units were determined from these data. Three monitoring station locations were determined during the original revision of this document. This first revision considers expanded Department of Energy operations south of the PNNL Site and relocation of the two offsite, northern monitoring stations to sites near the PNNL Site fenceline. Inclusion of the southern facilities resulted in the proposal for a fourth monitoring station in the southern region. The southern expansion added two minor emission unit facilities and one diffuse emission unit facility. Relocation of the two northern stations was possible due to the use of solar power, rather than the previous limitation of the need for access to AC power, at these more remote locations. Addendum A contains all the changes brought about by the revision 1 considerations. This DQO report also updates the discussion of the Environmental Monitoring Plan for the PNNL Site air samples and how existing Hanford Site monitoring program results could be used. This document of Data Quality Objectives (DQOs) was prepared based on the U.S. Environmental Protection Agency (EPA) Guidance on Systematic Planning Using the Data Quality Objectives Process, EPA, QA/G4, 2/2006 (EPA 2006) as well as several other published DQOs.

Barnett, J. M.; Meier, Kirsten M.; Snyder, Sandra F.; Fritz, Brad G.; Poston, Theodore M.; Antonio, Ernest J.

2012-11-12T23:59:59.000Z

47

Creating Climate Reference Datasets: CARDS Workshop on Adjusting Radiosonde Temperature Data for Climate Monitoring  

Science Conference Proceedings (OSTI)

Homogeneous upper-air temperature time series are necessary for climate change detection and attribution.About 20 participants met at the National Climatic Data Center in Asheville, North Carolina on 11-12 October 2000 to discuss methods of ...

Melissa Free; Imke Durre; Enric Aguilar; Dian Seidel; Thomas C. Peterson; Robert E. Eskridge; James K. Luers; David Parker; Margaret Gordon; John Lanzante; Stephen Klein; John Christy; Steven Schroeder; Brian Soden; Larry M. McMillin; Elizabeth Weatherhead

2002-06-01T23:59:59.000Z

48

Reference Design Description and Cost Evaluation for Compressed Air Energy Storage Systems  

Science Conference Proceedings (OSTI)

Compressed-air energy storage (CAES) is a valuable solution for mitigating the current challenges of renewable-power variability, facilitating higher renewable penetration levels, enhancing grid reliability, and improving the utilization of transmission and generation assets. However, capital costs play a critical role in evaluating the overall CAES value proposition, at least relative to direct-market revenues (energy and ancillary services). Although the first U.S. CAES plant in Alabama was built at co...

2011-12-21T23:59:59.000Z

49

Comprehensive Technical Report, General Electric Direct-Air-Cycle Aircraft Nuclear Propulsion Program, Program Summary and References  

SciTech Connect

This is one of twenty-one volumes sumarizing the Aircraft Nuclear Propulsion Program of the General Electric Company. This volume discusses the background to the General Electric program, and summarizes the various direct-air-cycle nuclear test assemblies and power plants that were developed. Because of the requirements of high performance, low weight, and small size, vast improvements in existing technology were required to meet the flight objectives. The technological progress achieved during the program is also summarized. The last appendix contains a compilation of the abstracts, tables of contents, and reference lists of the other twenty volumes.

Thornton, G.; Rothstein, A.J.

1962-06-28T23:59:59.000Z

50

A Proof Carrying Code Framework for Inlined Reference Monitors in Java Bytecode  

E-Print Network (OSTI)

We propose a light-weight approach for certification of monitor inlining for sequential Java bytecode using proof-carrying code. The goal is to enable the use of monitoring for quality assurance at development time, while minimizing the need for post-shipping code rewrites as well as changes to the end-host TCB. Standard automaton-based security policies express constraints on allowed API call/return sequences. Proofs are represented as JML-style program annotations. This is adequate in our case as all proofs generated in our framework are recognized in time polynomial in the size of the program. Policy adherence is proved by comparing the transitions of an inlined monitor with those of a trusted "ghost" monitor represented using JML-style annotations. At time of receiving a program with proof annotations, it is sufficient for the receiver to plug in its own trusted ghost monitor and check the resulting verification conditions, to verify that inlining has been performed correctly, of the correct policy. We ha...

Dam, Mads

2010-01-01T23:59:59.000Z

51

New and Emerging Technologies for Real-Time Air and Surface Beryllium Monitoring  

Science Conference Proceedings (OSTI)

In this study, five emerging technologies were identified for real-time monitoring of airborne beryllium: Microwave-Induced Plasma Spectroscopy (MIPS), Aerosol Beam-Focused Laser-Induced Plasma Spectroscopy (ABFLIPS), Laser-Induced Breakdown Spectroscopy (LIBS), Surfaced-Enhanced Raman Scattering (SERS) Spectroscopy, and Micro-Calorimetric Spectroscopy (CalSpec). Desired features of real-time air beryllium monitoring instrumentation were developed from the Y-12 CBDPP. These features were used as guidelines for the identification of potential technologies as well as their unique demonstrated capability to provide real-time monitoring of similar materials. However, best available technologies were considered, regardless of their ability to comply with the desired features. None of the five technologies have the capability to measure the particle size of airborne beryllium. Although reducing the total concentration of airborne beryllium is important, current literature suggests that reducing or eliminating the concentration of respirable beryllium is critical for worker health protection. Eight emerging technologies were identified for surface monitoring of beryllium. CalSpec, MIPS, SERS, LIBS, Laser Ablation, Absorptive Stripping Voltametry (ASV), Modified Inductively Coupled Plasma (ICP) Spectroscopy, and Gamma BeAST. Desired features of real-time surface beryllium monitoring were developed from the Y-12 CBDPP. These features were used as guidelines for the identification of potential technologies. However, the best available technologies were considered regardless of their ability to comply with the desired features.

Phifer, B.E. Jr.; Churnetski, E.L.; Cooke, L.E.; Reed, J.J.; Howell, M.L.; Smith, V.D.

2001-09-01T23:59:59.000Z

52

Developing a monitoring and verification plan with reference to the Australian Otway CO2 pilot project  

Science Conference Proceedings (OSTI)

The Australian Cooperative Research Centre for Greenhouse Gas Technologies (CO2CRC) is currently injecting 100,000 tons of CO{sub 2} in a large-scale test of storage technology in a pilot project in southeastern Australia called the CO2CRC Otway Project. The Otway Basin, with its natural CO{sub 2} accumulations and many depleted gas fields, offers an appropriate site for such a pilot project. An 80% CO{sub 2} stream is produced from a well (Buttress) near the depleted gas reservoir (Naylor) used for storage (Figure 1). The goal of this project is to demonstrate that CO{sub 2} can be safely transported, stored underground, and its behavior tracked and monitored. The monitoring and verification framework has been developed to monitor for the presence and behavior of CO{sub 2} in the subsurface reservoir, near surface, and atmosphere. This monitoring framework addresses areas, identified by a rigorous risk assessment, to verify conformance to clearly identifiable performance criteria. These criteria have been agreed with the regulatory authorities to manage the project through all phases addressing responsibilities, liabilities, and to assure the public of safe storage.

Dodds, K.; Daley, T.; Freifeld, B.; Urosevic, M.; Kepic, A.; Sharma, S.

2009-05-01T23:59:59.000Z

53

Compendium of selected references on air emissions; health, risk, and valuation research; and environmental externalities  

Science Conference Proceedings (OSTI)

In preparing to develop a cost-benefit methodology that could be applied to potential projects abroad involving new coal-fired power plants that make use of US clean coal technologies, the author reviewed a wide variety of reference sources. These are listed in this publication. Before this review, the author had conducted a number of literature searches that identified source material in the newly rediscovered field of environmental externalities and related topics that might also be of value to other energy and environmental researchers. Those sources that appeared to be appropriate but that the author was unable to review are also listed in this document. Thus, this document serves as a comprehensive compendium of source material on these subjects, arranged alphabetically within categories.

Szpunar, C.B.

1992-07-01T23:59:59.000Z

54

Monitoring and evaluation of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached houses in Austin, Texas  

SciTech Connect

The US DOE initiated this project to evaluate the performance of an air conditioner retrofit program in Austin, Texas. The City's Austin's Resource Management Department pursued this project to quantify the retrofit effect of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached homes. If successfully implemented, this retrofit program could help defer construction of a new power plant which is a major goal of this department. The project compares data collected from 12 houses during two cooling seasons under pre-retrofit and then post-retrofit air conditioner units. The existing low-efficiency air conditioners were monitored during the 1987 cooling season, replaced during the 1987--88 heating season with new, smaller sized, high-efficiency units, and then monitored again during the 1988 cooling season. Results indicated that the air conditioner retrofits reduce the annual air conditioner electric consumption and peak electric demand by an average of 38%. When normalized to the nominal capacity of the air conditioner, average demand savings were 1.12 W/ft{sup 2} and estimated annual energy savings were 1.419 kWh/ft{sup 2}. Individual air conditioner power requirements were found to be a well defined function of outdoor temperature as expected. In the absence of detailed data, estimates of the peak demand reductions of new air conditioners can be made from the manufacturer's specifications. Air conditioner energy consumption proved to be strongly linear as a function of the outdoor temperature as expected when taken as an aggregate. No noticeable differences in the diversity factor of the air conditioner usage were found. Analysis of the retrofit effect using PRISM yields estimates of the reduction in normalized annual consumption (NAC) and annual cooling consumption of 12% and 30%. 2 refs., 11 figs., 17 tabs.

Burns, R.; Hough, R.E. (Fleming (W.S.) and Associates, Inc., Syracuse, NY (United States))

1991-10-01T23:59:59.000Z

55

Use of MCNPX for Alpha Spectrometry Simulations of a Continuous Air Monitor  

Science Conference Proceedings (OSTI)

The purpose of this study was to determine if the alpha energy spectrum in a Passive Implanted Planar Silicon (PIPS) detector, as modeled by MCNPX [1], can be used to design a radon stripping algorithm for a continuous air monitor (CAM). This stripping algorithm would be employed to discriminate naturally occurring radioisotopes from the anthropogenic for nuclear safety -related applications. It is hoped that using an algorithm based on MCNPX simulations, the CAM will not be prone to false alarms when radon levels are dynamic as identified in other CAM systems [2,3]. This work is focused on the design of the next generation air particulate detector (NGAPD) for the United States Navy. The primary isotope of interest is Co-60. This radionuclide emits a beta with an average energy of 96 keV. Therefore, once deposited on the CAM filter, it will produce a beta continuum seen by the PIPS detector. In addition, as radon progeny is deposited on the air filter, these will give rise to characteristic alpha peaks and a beta continuum. This is primarily an issue in port-or land-based applications. Ultimately, measurement of a radon alpha spectrum is desired to predict the amount of beta activity which would be measured from the radon progeny decay chains. All excess beta activity could then be attributed to anthropogenic sources once the radon progeny contributions have been stripped out.

Robert Hayes, Craig Marianno

2007-01-01T23:59:59.000Z

56

Air Quality  

NLE Websites -- All DOE Office Websites (Extended Search)

What We Monitor & Why » What We Monitor & Why » Air Quality Air Quality To preserve our existing wilderness-area air quality, LANL implements a conscientious program of air monitoring. April 12, 2012 Real-time data monitoring for particulate matter An air monitoring field team member tests one of LANL's tapered element oscillating microbalance samplers, which collects real-time particulate matter data. Contact Environmental Communication & Public Involvement P.O. Box 1663 MS M996 Los Alamos, NM 87545 (505) 667-0216 Email LANL monitors air quality 24 hours a day, 365 days a year. Why we monitor air LANL monitors many different pathways in order to assess their impact on workers, the public, animals, and plants. We monitor the air around the Laboratory to ensure our operations are not affecting the air of nearby

57

Ambient air monitoring during the 2011 Las Conchas wildland fire near Los Alamos, U.S.A.  

SciTech Connect

Air monitoring data collected during the Las Conchas fire near the Los Alamos National Laboratory during 2011 are presented. Data included are for selected radionuclides and selected metals found in particulate matter. None of these analytes were seen at levels which exceeded any state or federal standards.

Green, Andrew A. [Los Alamos National Laboratory; Schlemann, Shea A. [Los Alamos Technical Associates; Young, Daniel L. [Los Alamos National Laboratory

2012-08-31T23:59:59.000Z

58

Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Tonopah Airport, Nye County, Nevada  

SciTech Connect

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Tonopah Airport, Beatty, Rachel, Caliente, Pahranagat NWR, Crater Flat, and the Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

J. Engelbrecht; I. Kavouras; D. Campbell; S. Campbell; S. Kohl; D. Shafer

2009-04-02T23:59:59.000Z

59

Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Pahranagat National Wildlife Refuge, Lincoln County, Nevada  

SciTech Connect

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Pahranagat NWR, Beatty, Rachel, Caliente, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data on completion of the site's sampling program.

J. Engelbrecht; I. Kavouras; D. Campbell; S. Campbell; S. Kohl; D. Shafer

2009-04-02T23:59:59.000Z

60

Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Crater Flat, Nye County, Nevada  

SciTech Connect

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) (cover page figure) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

J. Engelbrecht; I. Kavouras; D. Campbell; S.Campbell; S. Kohl; D. Shafer

2009-04-02T23:59:59.000Z

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Tonopah Airport, Nye County, Nevada  

Science Conference Proceedings (OSTI)

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Tonopah Airport, Beatty, Rachel, Caliente, Pahranagat NWR, Crater Flat, and the Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

J. Engelbrecht; I. Kavouras; D Campbell; S. Campbell; S. Kohl, D. Shafer

2008-08-01T23:59:59.000Z

62

Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Crater Flat, Nye County, Nevada  

Science Conference Proceedings (OSTI)

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) (cover page figure) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

J. Engelbrecht; I. Kavouras; D. Campbell; S. Campbell; S. Kohl; D. Shafer

2008-08-01T23:59:59.000Z

63

Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Pahranagat National Wildlife Refuge, Lincoln County, Nevada  

Science Conference Proceedings (OSTI)

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Pahranagat NWR, Beatty, Rachel, Caliente, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data on completion of the site's sampling program.

J. Englebrecht; I. Kavouras; D. Campbell; S. Campbell; S. Kohl; D. Shafer

2008-08-01T23:59:59.000Z

64

Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Caliente, Lincoln County, Nevada  

Science Conference Proceedings (OSTI)

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

J. Englebrecht; I. Kavouras; D. Campbell; S. Campbell; S. Kohl; D. Shafer

2008-08-01T23:59:59.000Z

65

Tonopah Test Range Air Monitoring: CY2012 Meteorological, Radiological, and Airborne Particulate Observations  

SciTech Connect

In 1963, the Atomic Energy Commission (AEC), predecessor to the US Department of Energy (DOE), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range (NAFR)). Operation Roller Coaster consisted of four tests in which chemical explosions were detonated in the presence of nuclear devices to assess the dispersal of radionuclides and evaluate the effectiveness of storage structures to contain the ejected radionuclides. These tests resulted in dispersal of plutonium over the ground surface downwind of the test ground zero. Three tests, Clean Slate 1, 2, and 3, were conducted on the TTR in Cactus Flat; the fourth, Double Tracks, was conducted in Stonewall Flat on the NTTR. DOE is working to clean up and close all four sites. Substantial cleaned up has been accomplished at Double Tracks and Clean Slate 1. Cleanup of Clean Slate 2 and 3 is on the DOE planning horizon for some time in the next several years. The Desert Research Institute installed two monitoring stations, number 400 at the Sandia National Laboratories Range Operations Center and number 401 at Clean Slate 3, in 2008 and a third monitoring station, number 402 at Clean Slate 1, in 2011 to measure radiological, meteorological, and dust conditions. The primary objectives of the data collection and analysis effort are to (1) monitor the concentration of radiological parameters in dust particles suspended in air, (2) determine whether winds are re-distributing radionuclides or contaminated soil material, (3) evaluate the controlling meteorological conditions if wind transport is occurring, and (4) measure ancillary radiological, meteorological, and environmental parameters that might provide insight to the above assessments. The following observations are based on data collected during CY2012. The mean annual concentration of gross alpha and gross beta is highest at Station 400 and lowest at Station 401. This difference may be the result of using filter media at Station 400 with a smaller pore size than the media used at the other two stations. Average annual gamma exposure at Station 401 is slightly greater than at Station 400 and 402. Average annual gamma exposure at all three TTR stations are in the upper range to slightly higher than values reported for the CEMP stations surrounding the TTR. At higher wind speeds, the saltation counts are greater at Station 401 than at Station 402 while the suspended particulate concentrations are greater at Station 402 than at Statin 401. Although these observations seem counterintuitive, they are likely the result of differences in the soil material present at the two sites. Station 401 is located on an interfluve elevated above two adjacent drainage channels where the soil surface is likely to be composed of coarser material. Station 402 is located in finer sediments at the playa edge and is also subject to dust from a dirt road only 500 m to the north. During prolonged high wind events, suspended dust concentrations at Station 401 peaked with the initial winds then decreased whereas dust concentrations at Station 402 peaked with each peak in the wind speed. This likely reflects a limited PM10 source that is quickly expended at Station 401 relative to an abundant PM10 source at Station 402. In CY2013, to facilitate comparisons between radiological analyses of collected dust, the filter media at all three stations will be standardized. In addition, a sequence of samples will be collected at Station 400 using both types of filter media to enable development of a mathematical relationship between the results derived from the two filter types. Additionally, having acquired approximately four years of observations at Stations 400 and 401 and a year of observations at Station 402, a period-of-record analysis of the radiological and airborne dust conditions will be undertaken.

Mizell, Steve A; Nikolich, George; Shadel, Craig; McCurdy, Greg; Miller, Julianne J

2013-07-01T23:59:59.000Z

66

Community Environmental Monitoring Program (CEMP) Data related to Air, Soil, and Water Monitoring around the Nevada Test Site  

DOE Data Explorer (OSTI)

The Community Environmental Monitoring Program (CEMP) is a network of 29 monitoring stations located in communities surrounding and downwind of the Nevada Test Site (NTS) that monitor the airborne environment for manmade radioactivity that could result from NTS activities. The network stations, located in Nevada, Utah, and California are comprised of instruments that collect a variety of environmental radiological and meteorological data. The emphasis of the CEMP is to monitor airborne radioactivity and weather conditions, and make the results available to the public. Instrumentation that records these data is connected to a datalogger, and real-time radiation levels or weather conditions can immediately and easily be seen on a display at each station. These data are transmitted via direct or wireless internet connection, landline or cellular phone, or satellite transmission to DRI's Western Regional Climate Center in Reno, Nevada, and are updated as frequently as every 10 minutes on the World Wide Web at http://www.cemp.dri.edu. DOE and DRI also publish the results of the monitoring program and distribute these reports throughout the network community. The reports provide summaries of average values for each station and the entire network, and show deviations from the expected range values. [Copied from the CEMP website (Introduction) at http://www.cemp.dri.edu/cemp/moreinfo.html

67

U.S. Climate Reference Network Soil Moisture and Temperature Observations  

Science Conference Proceedings (OSTI)

The U.S. Climate Reference Network (USCRN) is a network of climate-monitoring stations maintained and operated by the National Oceanic and Atmospheric Administration (NOAA) to provide climate-science-quality measurements of air temperature and ...

Jesse E. Bell; Michael A. Palecki; C. Bruce Baker; William G. Collins; Jay H. Lawrimore; Ronald D. Leeper; Mark E. Hall; John Kochendorfer; Tilden P. Meyers; Tim Wilson; Howard J. Diamond

2013-06-01T23:59:59.000Z

68

Air Pollution (Illinois)  

Energy.gov (U.S. Department of Energy (DOE))

This article states regulations for monitoring air pollution, methods for permit applications, emission limitations for pollutants and air quality standards.

69

Air pollutant monitoring for the East Bay Children's Respiratory Health Study  

SciTech Connect

This report describes the methodology and presents the summary results of the air pollutant monitoring program conducted by Lawrence Berkeley National Laboratory in support of the East Bay Children's Respiratory Health Study. The full study is examining the effects of chronic exposure to traffic-related pollutants on respiratory health among 3rd and 4th grade children attending ten neighborhood elementary schools in the San Francisco East Bay Area (Hayward, San Leandro and Oakland, CA). The demographically similar schools are located at varying distances from the I-880 and CA-92 freeways. Several schools were selected because they are located within 300 m in the predominant downwind direction (east) from either of the freeways. Measurements of multiple pollutants were made outdoors at the schools over 1-2 week intervals for 14 weeks in spring and eight weeks in fall 2001 using a custom-designed and validated package of commercially available monitoring equipment. Particulate matter was sampled over all hours (24 h per day) or during schools hours only with battery-operated programmable pumps and inlet devices for PM{sub 10} and PM{sub 2.5}. These pumps were modified to allow for up to 10 days of continuous operation. Fine particle mass and black carbon (BC) were determined from the collected filters. Nitrogen oxides (NO{sub x} and NO{sub 2}) were measured with passive samplers. Carbon monoxide (CO) was measured continuously with an electrochemical sensor. Gasoline-related volatile organic compounds (VOCs) were measured with passive samplers during three 4-week intervals in spring 2001 and two 4-week periods in early 2002. All samplers were deployed in a metal cabinet located outside at each school. Ranges of study average pollutant concentrations (all-hours) at the ten individual schools were: NO{sub x}, 33-68 ppb; NO{sub 2}, 19-31 ppb; PM{sub 10} mass, 27-32 {micro}g/m{sup 3}; PM{sub 2.5} mass, 12-15 {micro}g/m{sup 3}; and BC associated with PM{sub 2.5}, 0.6-1.0 {micro}g/m{sup 3}. Although statistical analysis of the data is yet to be performed, some general observations can be made. Absolute pollutant levels varied by season and week, but the simultaneous sampling design allowed for comparisons of concentrations among schools during each interval. Pollutant concentrations at each school were normalized to the sampling period averages among all schools. The normalized concentrations were generally consistent at each school throughout the entire study, suggesting that measured differences represent ongoing conditions and chronic exposures in the vicinities of the schools. Substantially elevated concentrations of NO{sub x}, NO{sub 2}, and BC, and somewhat elevated concentrations of PM{sub 2.5} were observed at one school located less than 100 meters to the east of I-880. Normalized concentrations of NO{sub x}, NO{sub 2}, and BC were also higher at the three other ''nearby and downwind'' schools relative to those located far from any freeway or other major traffic source. An ancillary monitoring program was implemented to examine the correlation between school-based pollutant measurements and measurements throughout the neighborhoods adjacent to three of the schools. Volunteer households were obtained from among the families of participating schoolchildren. Concentrations of NO{sub x} and NO{sub 2} were measured with passive samplers outside the homes of these volunteers during one of two 1-week periods in spring 2002. Simultaneous measurements were conducted at all ten of the schools and a central monitoring station during each week. The neighborhoods surrounding two schools were predominantly upwind of the I-880 freeway, while the neighborhood surrounding the other school was downwind from I-880. The overall distribution of concentrations observed for the residences near the downwind school appeared to be substantially higher than the regional background concentrations. The variability observed within the neighborhoods appeared to be, at least in part, explained by the proximity of individual residences to the freeway or

Singer, Brett C.; Hotchi, Toshifumi; Hodgson, Alfred T.

2002-11-01T23:59:59.000Z

70

INFLUENCE OF TEMPERATURE ON THE CORROSION POTENTIAL OF THE 241-AN-102 MULTI PROBE CORROSION MONITORING SYSTEM SECONDARY REFERENCE ELECTRODES  

SciTech Connect

A test program using 241-AN-102 waste simulants and metallic secondary reference electrodes similar to those used on the 241-AN-102 MPCMS was performed to characterize the relationship between temperature and secondary reference electrode open-circuit corrosion potential. This program showed that the secondary reference electrodes can be used to make tank and tank steel corrosion potential measurements, but that a correction factor of approximately 2 mV per degree Celsius of temperature difference must be applied, where temperature difference is defined as the difference between tank temperature at the time of measurement and 30 C, the average tank temperature during the first several months of 241-AN-102 MPCMS operation (when the corrosion potentials of the secondary reference electrodes were being recorded relative to the primary reference electrodes).

EDGEMON GL; TAYLOR TM

2008-09-30T23:59:59.000Z

71

Monitoring Air Quality from Space: The Case for the Geostationary Platform  

Science Conference Proceedings (OSTI)

Air quality (AQ) is defined by the atmospheric composition of gases and particulates near the Earth's surface. This composition depends on local emissions of pollutants, chemistry, and transport processes; it is highly variable in space and time. Key ...

W. A. Lahoz; V.-H. Peuch; J. Orphal; J.-L. Attié; K. Chance; X. Liu; D. Edwards; H. Elbern; J.-M. Flaud; M. Claeyman; L. El Amraoui

2012-02-01T23:59:59.000Z

72

Automatic monitoring of selected indoor air parameters at three apartment complexes  

SciTech Connect

The impact of three different ventilation systems on the temperature and humidity of three similar apartment complexes is investigated in this study. Each complex has six apartments. The ventilation systems are: natural ventilation, mechanical exhaust ventilation, and mechanical supply and exhaust ventilation. The computer controlled data collection system measures the ventilation rate, relative humidity, indoor air temperature, wind speed, wind direction, outdoor temperature, and humidity. The air change rate depends mainly on the habits of the tenants. The mean air change rate of the houses was between 0.1 to 0.8 ac/h. Great daily variation of the air exchange was observed in the data. Negative correlation between relative humidity and ventilation was very significant in 27 out of 47 cases. Only two cases had very significant positive correlation between ventilation and humidity. Mechanical supply and exhaust ventilation have the greatest variation in ventilation/relative humidity relations.

Savolainen, T.; Raunemaa, T (Univ. of Kuopio (Finland)); Wellman, K. (Technical Research Centre of Finland, Helsinki (Finland))

1989-01-01T23:59:59.000Z

73

Vapor concentration monitor  

DOE Patents (OSTI)

An apparatus for monitoring the concentration of a vapor, such as heavy water, having at least one narrow bandwidth in its absorption spectrum, in a sample gas such as air. The air is drawn into a chamber in which the vapor content is measured by means of its radiation absorption spectrum. High sensitivity is obtained by modulating the wavelength at a relatively high frequency without changing its optical path, while high stability against zero drift is obtained by the low frequency interchange of the sample gas to be monitored and of a reference sample. The variable HDO background due to natural humidity is automatically corrected.

Bayly, John G. (Deep River, CA); Booth, Ronald J. (Deep River, CA)

1977-01-01T23:59:59.000Z

74

Estimation of a semi-physical GLBE model using dual EnKF learning algorithm coupled with a sensor network design strategy: Application to air field monitoring  

Science Conference Proceedings (OSTI)

In this paper, we present the fusion of two complementary approaches for modeling and monitoring the spatio-temporal behavior of a fluid flow system. We also propose a mobile sensor deployment strategy to produce the most accurate estimate of the true ... Keywords: Air field monitoring, Grey-box modeling, Model fusion, Sensor network design

Gilles Roussel, Laurent Bourgois, Mohammed Benjelloun, Gilles Delmaire

2013-10-01T23:59:59.000Z

75

The use of electrochemical sensors for monitoring urban air quality in low-cost, high-density networks.  

E-Print Network (OSTI)

electrolyte reservoirs for increased long-term baseline stability, and larger integral batteries allowing operation for in excess of 3 months without intervention. In this case sensors were sealed with rubber O-rings on the bottom of the enclosure behind a... The use of electrochemical sensors for monitoring urban air quality in low-cost, high-density networks. M. I. Mead1*, O.A.M. Popoola1, G. B. Stewart1, P. Landshoff3, M. Calleja2, M. Hayes2, J. J. Baldovi1, T. F. Hodgson1, M. W. McLeod1, J. Dicks4...

Mead, M I; Popoola, O A M; Stewart, G B; Landshoff, P; Calleja, M; Hayes, M; Baldovi, J J; Hodgson, T F; McLeod, M W; Dicks, J; Lewis, A; Cohen, J; Baron, R; Saffell, J R; Jones, R L

76

Environmental baseline monitoring in the area of general crude oil - Department of Energy Pleasant Bayou Number 1 - a geopressured-geothermal test well, 1978. Volume III. Appendix II. Air quality monitoring, Radian Corporation, Austin, Texas. Annual report  

DOE Green Energy (OSTI)

The air monitoring program, instrument types, and bag sampling program are described in each of five quarterly reports. The operating statistics for each of the major subsystems contained in the monitoring station are presented. National ambient air quality standards are presented for criteria pollutants and the monthly statistics for the monitoring station for the month are displayed. Daily averages, maximum daily five-minute averages retained in the data base as well as the times of occurrence, the five largest averages, and the diurnal variation of various recording times are tabulated. (MHR)

Gustavson, T.C.

1979-01-01T23:59:59.000Z

77

REFERENCES CITED IN: Draft Technical Report: Considerations Related to Post-Closure Monitoring Of Uranium In-Situ  

E-Print Network (OSTI)

, 2008, Cogema Mining, Inc, and Petrotek Engineering Corp. ML081060131. http://www.wise- uranium://www.wiley.com/WileyCDA/ Crow Butte 2000. Mine Unit 1 Restoration Report, Crow Butte Uranium Project. Submitted to NRC January Of Uranium In-Situ Leach/In-Situ Recovery (ISL/ISR) Sites. How to obtain the references: Most

78

Los Alamos Air Monitoring Data Related to the Fukushima Daiichi Reactor  

SciTech Connect

In response to the disasters in Japan on March 11, 2011, Los Alamos National Laboratory (LANL) is collecting air data and analyzing the data for fission products. At present, we report preliminary data from three high-volume air samplers and one stack sampler. Iodine-131 (I-131) is not optimally measured by our standard polypropylene filters. In addition to the filter data, we have one measurement obtained from a charcoal cartridge. These data, together with measurements of other radionuclides are adequate for a preliminary assessment and assure us that radionuclides from Fukushima Daiichi do not present a threat to human health at or near Los Alamos.

McNaughton, Michael [Los Alamos National Laboratory

2011-01-01T23:59:59.000Z

79

Real-time air quality monitoring through mobile sensing in metropolitan areas  

Science Conference Proceedings (OSTI)

Traditionally, pollution measurements are performed using expensive equipment at fixed locations or dedicated mobile equipment laboratories. This is a coarse-grained and expensive approach where the pollution measurements are few and far in-between. ... Keywords: air quality, mobile sensing, participatory sensing, pollution, social networks, urban sensing

Srinivas Devarakonda, Parveen Sevusu, Hongzhang Liu, Ruilin Liu, Liviu Iftode, Badri Nath

2013-08-01T23:59:59.000Z

80

Monitoring the Performance of a Residential Central Air Conditioner under Degraded Conditions on a Test Bench  

E-Print Network (OSTI)

This report presents the measured degradation in performance of a residential air conditioning system operating under degraded conditions. Experiments were conducted using a R-22 threeton split-type cooling system with a short-tube orifice expansion device. Results are presented here for a series of tests in which the various commonly occurring degraded conditions were simulated on a test bench. At present, very little information is available which quantifies the performance of a residential cooling system operating under degraded conditions. Degraded performance measurements can provide information which could help electric utilities evaluate the potential impact of systemwide maintenance programs. This report also discuss the development of a diagnostic procedure based on measurement of refrigerant and air side temperatures.

Palani, M.; O'Neal, D. L.; Haberl, J. S.

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Air Monitoring Modeling of Radioactive Releases During Proposed PFP Complex Demolition Activities  

Science Conference Proceedings (OSTI)

This report is part of the planning process for the demolition of the 234-5Z, 236-Z, 242-Z, and 291-Z-1 structures at the Plutonium Finishing Plant (PFP) facilities on the Hanford Site. Pacific Northwest National Laboratory (PNNL) supports the U.S. Department of Energy (DOE) and the CH2M HILL Plateau Remediation Company (CHPRC) demolition planning effort by making engineering estimates of potential releases for various potential demolition alternatives. This report documents an analysis considering open-air demolition using standard techniques. It does not document any decisions about the decommissioning approaches; it is expected that this report will be revisited as demolition plans are finalized.

Napier, Bruce A.; Droppo, James G.; Rishel, Jeremy P.

2011-01-24T23:59:59.000Z

82

Air Monitoring Network at Tonopah Test Range: Network Description, Capabilities, and Analytical Results  

SciTech Connect

During the period April to June 2008, at the behest of the Department of Energy (DOE), National Nuclear Security Administration, Nevada Site Office (NNSA/NSO); the Desert Research Institute (DRI) constructed and deployed two portable environmental monitoring stations at the Tonopah Test Range (TTR) as part of the Environmental Restoration Project Soils Activity. DRI has operated these stations since that time. A third station was deployed in the period May to September 2011. The TTR is located within the northwest corner of the Nevada Test and Training Range (NTTR), and covers an area of approximately 725.20 km2 (280 mi2). The primary objective of the monitoring stations is to evaluate whether and under what conditions there is wind transport of radiological contaminants from Soils Corrective Action Units (CAUs) associated with Operation Roller Coaster on TTR. Operation Roller Coaster was a series of tests, conducted in 1963, designed to examine the stability and dispersal of plutonium in storage and transportation accidents. These tests did not result in any nuclear explosive yield. However, the tests did result in the dispersal of plutonium and contamination of surface soils in the surrounding area.

Hartwell William T.,Daniels Jeffrey,Nikolich George,Shadel Craig,Giles Ken,Karr Lynn,Kluesner Tammy

2012-01-01T23:59:59.000Z

83

Air Monitoring Network at Tonopah Test Range: Network Description and Capabilities  

SciTech Connect

During the period April to June 2008, at the behest of the U.S. Department of Energy (DOE) National Nuclear Security Administration, Nevada Site Office (NNSA/NSO); the Desert Research Institute (DRI) constructed and deployed two portable environmental monitoring stations at the Tonopah Test Range (TTR) as part of the Environmental Restoration Project Soils Sub-Project. The TTR is located within the boundaries of the Nevada Test and Training Range (NTTR) near the northern edge, and covers an area of approximately 725.20 km2 (179,200 acres). The primary objective of the monitoring stations is to evaluate whether and under what conditions there is wind transport of radiological contaminants from one of the three Soil Sub-Project Corrective Action Units (CAUs) associated with Operation Roller Coaster on TTR. Operation Roller Coaster was a series of tests, conducted in 1963, designed to examine the stability and dispersal of plutonium in storage and transportation accidents. These tests did not result in any nuclear explosive yield. However, the tests did result in the dispersal of plutonium and contamination of surface soils in the surrounding area.

Jeffrey Tappen; George Nikolich; Ken Giles; David Shafer; Tammy Kluesner

2010-05-18T23:59:59.000Z

84

A sensor management architecture concept for monitoring emissions from open-air demil operations.  

Science Conference Proceedings (OSTI)

Sandia National Laboratories, CA proposed a sensor concept to detect emissions from open-burning/open-detonation (OB/OD) events. The system would serve two purposes: (1) Provide data to demilitarization operations about process efficiency, allowing process optimization for cleaner emissions and higher efficiency. (2) Provide data to regulators and neighboring communities about materials dispersing into the environment by OB/OD operations. The proposed sensor system uses instrument control hardware and data visualization software developed at Sandia National Laboratories to link together an array of sensors to monitor emissions from OB/OD events. The suite of sensors would consist of various physical and chemical detectors mounted on stationary or mobile platforms. The individual sensors would be wirelessly linked to one another and controlled through a central command center. Real-time data collection from the sensors, combined with integrated visualization of the data at the command center, would allow for feedback to the sensors to alter operational conditions to adjust for changing needs (i.e., moving plume position, increased spatial resolution, increased sensitivity). This report presents a systems study of the problem of implementing a sensor system for monitoring OB/OD emissions. The goal of this study was to gain a fuller understanding of the political, economic, and technical issues for developing and fielding this technology.

Johnson, Michael M.; Robinson, Jerry D.; Stoddard, Mary Clare; Horn, Brent A.; Lipkin, Joel; Foltz, Greg W.

2005-09-01T23:59:59.000Z

85

Data Quality Objectives Supporting Radiological Air Emissions Monitoring for the Marine Sciences Laboratory, Sequim Site  

Science Conference Proceedings (OSTI)

This document of Data Quality Objectives (DQOs) was prepared based on the U.S. Environmental Protection Agency (EPA) Guidance on Systematic Planning Using the Data Quality Objectives Process, EPA, QA/G4, 2/2006 (EPA 2006), as well as several other published DQOs. The intent of this report is to determine the necessary steps required to ensure that radioactive emissions to the air from the Marine Sciences Laboratory (MSL) headquartered at the Pacific Northwest National Laboratory’s Sequim Marine Research Operations (Sequim Site) on Washington State’s Olympic Peninsula are managed in accordance with regulatory requirements and best practices. The Sequim Site was transitioned in October 2012 from private operation under Battelle Memorial Institute to an exclusive use contract with the U.S. Department of Energy, Office of Science, Pacific Northwest Site Office.

Barnett, J. M.; Meier, Kirsten M.; Snyder, Sandra F.; Antonio, Ernest J.; Fritz, Brad G.; Poston, Theodore M.

2012-12-27T23:59:59.000Z

86

Twelve Months of Air Quality Monitoring at Ash Meadows National Wildlife Refuge, Southwestern Rural Nevada, U.S.A (EMSI April 2007)  

SciTech Connect

The one year of air quality monitoring data collected at the Ash Meadows National Wildlife Refuge (NWR) was the final part of the air quality "Scoping Studies" for the Environmental Monitoring Systems Initiative (EMSI) in southern and central Nevada. The objective of monitoring at Ash Meadows was to examine aerosol and meteorological data, seasonal trends in aerosol and meteorological parameters as well as to examine evidence for long distance transport of some constituents. The 9,307 hectare refuge supports more than 50 springs and 24 endemic species, including the only population of the federally listed endangered Devil’s Hole pupfish (Cyprinodon diabolis) (U.S. Fish and Wildlife Service, 1990). Ash Meadows NWR is located in a Class II air quality area, and the aerosol measurements collected with this study are compared to those of Interagency Monitoring of Protected Visual Environments (IMPROVE) sites. Measurements taken at Ash Meadows NWR over a period of 12 months provide new baseline air quality and meteorological information for rural southwestern Nevada, specifically Nye County and the Amargosa Valley.

Engelbrecht, Johann P; Shafer, David S; Campbell, Dave; Campbell, Scott; McCurdy, Greg; Kohl, Steven D; Nikolich, George; Sheetz, Larry

2011-08-01T23:59:59.000Z

87

DOE/NV/26383-LTR2008-01 Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Caliente, Lincoln County, Nevada  

Science Conference Proceedings (OSTI)

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

J. Engelbrecht; I. Kavouras; D. Campbell; S. Campbell; S. Kohl; D. Shafer

2009-04-02T23:59:59.000Z

88

Manual on indoor air quality  

Science Conference Proceedings (OSTI)

This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues.

Diamond, R.C.; Grimsrud, D.T.

1983-12-01T23:59:59.000Z

89

NETL: IEP - Air Quality Research  

NLE Websites -- All DOE Office Websites (Extended Search)

Home > Technologies > Coal & Power Systems > Innovations for Existing Plants > Air Quality Research Home > Technologies > Coal & Power Systems > Innovations for Existing Plants > Air Quality Research Innovations for Existing Plants Air Quality Research Ambient Monitoring Emissions Characterization Predictive Modeling & Evaluation Health Effects Regulatory Drivers Air Quality Research Reference Shelf The NETL Air Quality Research program is designed to resolve the scientific uncertainties associated with the atmospheric formation, distribution, and chemical transformation of pollutant emissions from today's coal-fired power plants, and to obtain a realistic assessment of the human health impacts of these emissions. Results of this research will help the DOE Office of Fossil Energy address policy questions regarding coal plant emissions and provide guidance for future emissions control R&D programs at

90

Feasibility of air capture  

E-Print Network (OSTI)

Capturing CO2 from air, referred to as Air Capture, is being proposed as a viable climate change mitigation technology. The two major benefits of air capture, reported in literature, are that it allows us to reduce the ...

Ranjan, Manya

2010-01-01T23:59:59.000Z

91

Prediction and Monitoring of Clear-Air Turbulence: An Evaluation of the Applicability of the Rawinsonde System  

Science Conference Proceedings (OSTI)

The ability to sense turbulent layers in the free atmosphere is a fundamental requirement necessary for further progress in the area of clear air turbulence (CAT) prediction. Results from an investigation of the applicability of rawinsonde (RW) ...

John L. Keller

1981-06-01T23:59:59.000Z

92

Comparison of Near-field and Far-field Air Monitoring of Plutonium-contaminated Soils from the Tonopah Test Range, Nevada  

SciTech Connect

Operation Roller Coaster, a series of nuclear material dispersal experiments, resulted in three areas (Clean Slates 1, 2, and 3) of widespread surface soil plutonium (Pu) contamination on the Tonopah Test Range (TTR), located 225 miles northwest of Las Vegas, Nevada. The State's Division of Environmental Protection raised concerns that dispersal of airborne Pu particles from the sites could result in undetected deposition further downwind that the background monitoring stations. Air monitoring data from different distances from the Clean Slate sites but during the same period of time were compared. From the available data, there is no indication that airborne PM10 particles are being transported to the farther distance,however, the data are statistically insufficient to conclude whether there is a difference in transport of respirable Pu particles to the closer verses the farther sites from the Clean Slate sites.

John L. Bowen; David S. Shafer

2001-05-01T23:59:59.000Z

93

Oklahoma Clean Air Act (Oklahoma)  

Energy.gov (U.S. Department of Energy (DOE))

This legislation establishes the authority for the Oklahoma Department of Environmental Quality to administer programs to maintain and monitor air quality across Oklahoma. The Department monitors...

94

Climate Reference Network Daily01 Product | Data.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Daily01 Product Daily01 Product Agriculture Community Menu DATA APPS EVENTS DEVELOPER STATISTICS COLLABORATE ABOUT Agriculture You are here Data.gov » Communities » Agriculture » Data Climate Reference Network Daily01 Product Dataset Summary Description The U.S. Climate Reference Network is designed specifically to monitor national climate change with best scientific practice and adherence to the accepted principles of climate observations. USCRN daily temperature mean, maximum, and minimum, daily precipitation, daily global solar radiation, and daily average surface infrared temperature data are available in the Daily01 file set for all stations in the network. Daily mean, maximum, and minimum relative humidity are available for most stations. Tags {"Climate Reference Network",USCRN,CRN,"air temperature",temperature,precipitation,"global solar radiation"," surface temperature","surface infrared temperature","relative humidity","natural resources",water,air,"soil "}

95

References - CECM  

E-Print Network (OSTI)

help · annotate · Contents Next: About this document Up: RamanujanModular Equations, Previous: Sources · [Annotate] · [Shownotes]. References.

96

Selected References  

Science Conference Proceedings (OSTI)

...R. Paura, Laser Weld Quality Monitoring, Welding Fundamentals and Processes, Vol 6A, ASM Handbook, ASM International, 2011, p 595â??605...

97

Environmental Quality: Air (Louisiana)  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Environmental Quality regulates air quality in Louisiana. The Department has an established a fee system for funding the monitoring, investigation and other activities required...

98

Reference Tools  

NLE Websites -- All DOE Office Websites (Extended Search)

Reference Tools Current Greenhouse Gas Concentrations Name that compound: The numbers game for CFCs, HFCs, HCFCs, and Halons Conversion Tables and More Glossary Acronyms CDIAC's...

99

A post-occupancy monitored evaluation of the dimmable lighting, automated shading, and underfloor air distribution system in The New York Times Building  

NLE Websites -- All DOE Office Websites (Extended Search)

23E 23E A Post-Occupancy Monitored Evaluation of the Dimmable Lighting, Automated Shading, and Underfloor Air Distribution System in The New York Times Building E.S. Lee, L.L. Fernandes, B. Coffey, A. McNeil, R. Clear Lawrence Berkeley National Laboratory T. Webster, F. Bauman, D. Dickerhoff, D. Heinzerling, T. Hoyt University of California Berkeley Windows and Envelope Materials Group Building Technology and Urban Systems Department Environmental Energy Technologies Division January 2013 ! 2 Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the University of California, nor any of their employees, makes any warranty,

100

Continuous Emissions Monitoring Guidelines  

Science Conference Proceedings (OSTI)

Since the 2002 update of this manual, the Environmental Protection Agency (EPA) has been extremely active in its efforts to expand continuous emissions monitoring (CEM) requirements through a variety of regulatory instruments. Additional monitoring requirements have resulted from EPA's Clean Air Interstate Rule and Cross-State Air Pollution Rule. EPA attempted to impose mercury (Hg) monitoring requirements in its now-vacated Clean Air Mercury Rule. Most recently, EPA has proposed mercury, particulate mat...

2011-12-20T23:59:59.000Z

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

New Reference Standards for Digital Mammography  

Science Conference Proceedings (OSTI)

New Reference Standards for Digital Mammography. ... The NIST 100 kV tungsten anode x-ray unit and the Ritz primary standard free-air ionization ...

2013-03-13T23:59:59.000Z

102

Reference Shelf  

NLE Websites -- All DOE Office Websites (Extended Search)

Reference Shelf Reference Shelf Reference Shelf Find reference sources Questions? 505-667-5809 Email Biography Biographies of Women in Science Biography.com Marquis Who's Who NobelPrize.org Nobel Prize Internet Archive Calculators Currency Converter OnlineConversion.com Wolfram|Alpha Computational Knowledge Engine Dictionaries Oxford English Dictionary Merriam-Webster Dictionary DOD Dictionary of Military Terms Encyclopedias Britannica Online Columbia Encyclopedia Wikipedia Grants & Funding DOE Office of Science Grants & Contracts National Science Foundation National Institutes of Health Grants.Gov FedBizOpps.gov Los Alamos Info Los Alamos County Los Alamos Historical Society University of New Mexico - Los Alamos Campus Maps Atlapedia Online Perry-Casteneda Library Map Collection U.S. Gazetteer

103

Aluminum reference electrode  

DOE Patents (OSTI)

A stable reference electrode for use in monitoring and controlling the process of electrolytic reduction of a metal. In the case of Hall cell reduction of aluminum, the reference electrode comprises a pool of molten aluminum and a solution of molten cryolite, Na.sub.3 AlF.sub.6, wherein the electrical connection to the molten aluminum does not contact the highly corrosive molten salt solution. This is accomplished by altering the density of either the aluminum (decreasing the density) or the electrolyte (increasing the density) so that the aluminum floats on top of the molten salt solution.

Sadoway, Donald R. (Belmont, MA)

1988-01-01T23:59:59.000Z

104

Aluminum reference electrode  

DOE Patents (OSTI)

A stable reference electrode is described for use in monitoring and controlling the process of electrolytic reduction of a metal. In the case of Hall cell reduction of aluminum, the reference electrode comprises a pool of molten aluminum and a solution of molten cryolite, Na[sub 3]AlF[sub 6], wherein the electrical connection to the molten aluminum does not contact the highly corrosive molten salt solution. This is accomplished by altering the density of either the aluminum (decreasing the density) or the electrolyte (increasing the density) so that the aluminum floats on top of the molten salt solution. 1 fig.

Sadoway, D.R.

1988-08-16T23:59:59.000Z

105

STANDARD REFERENCE  

E-Print Network (OSTI)

The profession is strongly urged to use the standard reference on the financial framework in the EU, concerning endorsed IFRS in order to give a clear message to the market and to users of financial statements in and outside the EU.

unknown authors

2005-01-01T23:59:59.000Z

106

Radionuclide Air Emission Report for 2008  

E-Print Network (OSTI)

Fugitive Air Emissions of Radionuclides from Diffuse SourcesHazardous Air Pollutants (Radionuclides), Availability ofLBNL to Revise Its Radionuclide NESHAP Monitoring Approach,”

Wahl, Linnea

2009-01-01T23:59:59.000Z

107

air_water.cdr  

Office of Legacy Management (LM)

12/2011 12/2011 Air Monitoring Groundwater Monitoring Surface Water Monitoring A continuously operating air monitoring network was in place from 1986 through 2000 for the Weldon Spring Site Remedial Action Project (WSSRAP) to measure levels of gamma radiation, radioactive dust particles, radon gas, and asbestos. With remediation of contaminated materials essentially complete and measurements indistinguishable from background, the U.S. Department of Energy (DOE) ceased perimeter and offsite air monitoring as of December 31, 2000. Groundwater has been routinely monitored at the site since 1986. Separate groundwater monitoring programs were established for the Chemical Plant and Quarry sites because of geographic separation and differences in the hydrogeologic features that influence

108

Aire Valley Environmental | Open Energy Information  

Open Energy Info (EERE)

search Name Aire Valley Environmental Place United Kingdom Product Leeds-based waste-to-energy project developer. References Aire Valley Environmental1 LinkedIn...

109

China-GHG Monitoring | Open Energy Information  

Open Energy Info (EERE)

form form View source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit with form History Facebook icon Twitter icon » China-GHG Monitoring (Redirected from GIZ-China GHG Monitoring) Jump to: navigation, search Name China - GHG Monitoring Agency/Company /Organization German Agency for International Cooperation (GIZ), Center for Clean Air Policy Partner on behalf of the Federal Ministry for the Environment, Nature Conservation and Nuclear Safety (BMU) Sector Energy Focus Area Energy Efficiency Topics Low emission development planning Program Start 2011 Program End 2014 Country China Eastern Asia References GTZ in the People's Republic of China[1] Overview The project aims to develop capacities for a GHG-Monitoring system and an

110

Strategic Petroleum Reserve annual environmental monitoring report, 1983  

Science Conference Proceedings (OSTI)

Progress made in the monitoring and inspection program for the Strategic Petroleum Reserve during 1983 is reported. The following sites were monitored: Bayou Choctau, Bryan Mound, St. James Terminal, Sulfur Mines, Weeks Island and West Hackberry. Discussion is presented under the headings: air quality monitoring; oil spills and NPDES compliance; and water quality monitoring. The discussion on water quality monitoring is by far the most extensive. Surface waters from the sites previously mentioned were sampled and monitored for general water quality (except for St. James Terminal where there is a lack of potentially impacted surface waters). The following parameters were measured: pH value; salinity; total suspended particulates; temperature; dissolved oxygen; biochemical oxygen demand; oil and grease; and general observations. 12 references, 6 figures. (DMC)

Not Available

1984-03-31T23:59:59.000Z

111

Subject: References:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Subject: Subject: References: DEAR 970.3102-2 Compensation for personal services DEAR 970.5204-13 Allowable costs and fixed-fee (Management and operating contracts) DEAR 970.5204-14 Allowable costs and fixed-fee (support contracts) When is this ~\.cquisition Letter (AL) Effective? This AL is effective 10 days from the date of issuance. This gui~ce supersedes any previous statutory cap on executive compensation. Existing contracts need to be reviewed to determine whether contract terms and conditions are consistent with the guidance in this AL, or whether contract modifications are necessary. When Does this AL Expire? This AL remain;; in effect until superseded or canceled. Whom do you Contact for More Information? Contact the Office of Procurement and Assistance Policy, for questions pertaining to the

112

NISTIR 7799, Continuous Monitoring Reference Model ...  

Science Conference Proceedings (OSTI)

... also like to thank the United States Chief Information Officer Council's Information ... subsystems and therefore acts as an aggregation database (it is ...

2013-04-25T23:59:59.000Z

113

Subsurface Knowledge Reference Page | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Subsurface Knowledge Reference Page Subsurface Knowledge Reference Page Subsurface Knowledge Reference Page The below listing provides additional references related to Subsurface & Groundwater Remediation. The references are categorized by documents types (e.g., Strategic Plans, Groundwater Plume Map Booklets, etc.) and under each "document type", there is a list of documents and/or hyperlinks to a reference. The Subsurface Knowledge Reference Page will continue to reflect additional information as it is identified. Strategic Plans Scientific Opportunities to Reduce Risk in Groundwater and Soil Remediation Scientific Opportunities for Monitoring at Environmental Remediation Sites (SOMERS) Groundwater Plume Map Booklets Groundwater Contamination and Treatment at Department of Energy Sites -

114

SolarAire LLC | Open Energy Information  

Open Energy Info (EERE)

SolarAire LLC Place Folsom, California Sector Solar Product Developing a solar thermal air conditioning unit. References SolarAire LLC1 LinkedIn Connections CrunchBase Profile...

115

DunoAir | Open Energy Information  

Open Energy Info (EERE)

DunoAir Jump to: navigation, search Name DunoAir Place Hessen, Germany Zip 6865 VX Sector Wind energy Product Doorwerth-based wind project developer. References DunoAir1 LinkedIn...

116

air_water.cdr  

Office of Legacy Management (LM)

Office of Legacy Management Weldon Spring Site Air and Water Monitoring 32008 This fact sheet provides information at Weldon Spring, Missouri. This site is managed by the U.S....

117

What We Monitor & Why  

NLE Websites -- All DOE Office Websites (Extended Search)

by monitoring wildlife, plants, water quality, and air quality. June 27, 2012 Raft Trip: rafts on the Rio Grande Workers prepare for the annual Fall sampling campaign on the...

118

NEWTON's Physics References  

NLE Websites -- All DOE Office Websites (Extended Search)

Physics References Do you have a great physics reference link? Please click our Ideas page. Featured Reference Links: Physics Links Physics Links from AAPT See the American...

119

NEWTON's Chemistry References  

NLE Websites -- All DOE Office Websites (Extended Search)

Chemistry References Do you have a great chemistry reference link? Please click our Ideas page. Featured Reference Links: Steve Marsden's Chemistry Resources Steve Marsden's...

120

NETL: Carbon Storage - Reference Shelf  

NLE Websites -- All DOE Office Websites (Extended Search)

Carbon Storage > Reference Shelf Carbon Storage > Reference Shelf Carbon Storage Reference Shelf Below are links to Carbon Storage Program documents and reference materials. Each of the 10 categories has a variety of documents posted for easy access to current information - just click on the category link to view all related materials. RSS Icon Subscribe to the Carbon Storage RSS Feed. Carbon Storage Collage 2012 Carbon Utilization and Storage Atlas IV Carbon Sequestration Project Portfolio DOE/NETL Carbon Dioxide Capture and Storage RD&D Roadmap Public Outreach and Education for Carbon Storage Projects Carbon Storage Technology Program Plan Carbon Storage Newsletter Archive Impact of the Marcellus Shale Gas Play on Current and Future CCS Activities Site Screening, Selection, and Initial Characterization for Storage of CO2 in Deep Geologic Formations Carbon Storage Systems and Well Management Activities Monitoring, Verification, and Accounting of CO2 Stored in Deep Geologic Formations

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Long life reference electrode  

DOE Patents (OSTI)

An external, reference electrode is provided for long term use with a high temperature, high pressure system. The electrode is arranged in a vertical, electrically insulative tube with an upper portion serving as an electrolyte reservoir and a lower portion in electrolytic communication with the system to be monitored. The lower end portion includes a flow restriction such as a porous plug to limit the electrolyte release into the system. A piston equalized to the system pressure is fitted into the upper portion of the tube to impart a small incremental pressure to the electrolyte. The piston is selected of suitable size and weight to cause only a slight flow of electrolyte through the porous plug into the high pressure system. This prevents contamination of the electrolyte but is of such small flow rate that operating intervals of a month or more can be achieved. 2 figs.

Yonco, R.M.; Nagy, Z.

1989-04-04T23:59:59.000Z

122

Materials Reference Books  

Science Conference Proceedings (OSTI)

Materials Science Reference Books. ... The Smithells Metals Reference Book Brandis and Brook; Butterworth-Heinemann; Published 1992; ISBN ...

2010-10-05T23:59:59.000Z

123

Development of a Low-Cost Particulate Matter Monitor  

NLE Websites -- All DOE Office Websites (Extended Search)

could also be applied to ventilation control for better indoor air quality with lower energy expenditure, monitoring airplane cabin air quality and improving industrial...

124

Microfabricated fuel heating value monitoring device  

DOE Patents (OSTI)

A microfabricated fuel heating value monitoring device comprises a microfabricated gas chromatography column in combination with a catalytic microcalorimeter. The microcalorimeter can comprise a reference thermal conductivity sensor to provide diagnostics and surety. Using microfabrication techniques, the device can be manufactured in production quantities at a low per-unit cost. The microfabricated fuel heating value monitoring device enables continuous calorimetric determination of the heating value of natural gas with a 1 minute analysis time and 1.5 minute cycle time using air as a carrier gas. This device has applications in remote natural gas mining stations, pipeline switching and metering stations, turbine generators, and other industrial user sites. For gas pipelines, the device can improve gas quality during transfer and blending, and provide accurate financial accounting. For industrial end users, the device can provide continuous feedback of physical gas properties to improve combustion efficiency during use.

Robinson, Alex L. (Albuquerque, NM); Manginell, Ronald P. (Albuquerque, NM); Moorman, Matthew W. (Albuquerque, NM)

2010-05-04T23:59:59.000Z

125

Air Pollution Control Rules (West Virginia)  

Energy.gov (U.S. Department of Energy (DOE))

The listed rules were enacted as directed by the Air Pollution Control Act. Together, these rules guide the monitoring, permitting and compliance enforcement of air quality in the state.

126

Quality Reference Samples  

Science Conference Proceedings (OSTI)

Peer-reviewed fats and oils related performance-based control samples for lab quality assurance and quality control. Quality Reference Samples Certified Reference Materials (CRM) aocs certified Certified Reference Materials chemists CRM fat fats lab labo

127

COSY INFINITY Reference Manual  

E-Print Network (OSTI)

7.2, user's refer- ence manual. Technical Report CERN/LEP-COSY INFINITY Reference Manual M. Berz J I July 1990COSY INFlNlTY REFERENCE MANUAL * Martin Berz Accelerator and

Berz, M.

2010-01-01T23:59:59.000Z

128

Shift Reference Manual  

E-Print Network (OSTI)

BERKELEY Shift Reference Manual Akash Deshpande Aleks Göllü1055-1425 S HIFT Reference Manual PRCS project SHIC versionThis is a reference manual for S HIFT . It presents its

Deshpande, Akash; Gollu, Aleks; Semenzato, Luigi

1997-01-01T23:59:59.000Z

129

NEWTON's Computer Science References  

NLE Websites -- All DOE Office Websites (Extended Search)

Computer Science References Do you have a great computer reference link? Please click our Ideas page. Featured Reference Links: w3schools.com w3schools.com The site, w3schools.com,...

130

Compressed Air Energy Storage Act (Kansas)  

Energy.gov (U.S. Department of Energy (DOE))

This act lays out regulations for the local authorities related to site selection, design, operation and monitoring for underground storage of compressed air.

131

Radionuclide Air Emission Report for 2007  

E-Print Network (OSTI)

for Emissions of Radionuclides Other Than Radon FromHazardous Air Pollutants (Radionuclides), Availability ofLBNL to Revise Its Radionuclide NESHAP Monitoring Approach,”

Wahl, Linnea

2008-01-01T23:59:59.000Z

132

References: See Enclosure 1  

E-Print Network (OSTI)

a. Reissues DoD 4140.65-M (Reference (a)) in accordance with the authority in DoD Directive 5134.12 (Reference (b)) to establish guidance for the issuance, use, and disposal of wood packaging material (WPM) in compliance with International Standards for Phytosanitary Measures (ISPM) Number 15 (Reference (c)). When used as an adjective in this Manual, Reference (c) will be referred to as “ISPM No. 15.” b. Issues WPM procedures to:

unknown authors

2012-01-01T23:59:59.000Z

133

CONTAM Applications References  

Science Conference Proceedings (OSTI)

... Axley, J. (1999). Passive Ventilation for Residential Air Quality Control. ASHRAE Transactions 105(2). Musser, A. (2000). ... ASHRAE (1999). ...

134

Monitor Worldwide  

NLE Websites -- All DOE Office Websites (Extended Search)

NRC guidance on the need for integration of performance assessment and data collection NUREG-1573 Monitor Scientific Monitoring Monitoring * Two distinct situations - A proposed...

135

BROOKHAVEN NATIONAL LABORATORY ENVIRONMENTAL MONITORING PLAN  

Science Conference Proceedings (OSTI)

Triennial update that describes the BNL Environmental Monitoring Program for all media (air, surface water, ground water, etc.) in accordance with DOE ORDER 5400.5

DAUM,M.; DORSCH,WM.; FRY,J.; GREEN,T.; LEE,R.; NAIDU,J.; PAQUETTE,D.; SCARPITTA,S.; SCHROEDER,G.

1999-09-22T23:59:59.000Z

136

Identification and Tracking of Polluted Air Masses in the South-Central Coast Air Basin  

Science Conference Proceedings (OSTI)

Canister samples of air taken during the South-Central Coast Cooperative Air Monitoring Program (SCCCAMP) 1985 field study program were analyzed for concentrations of over 50 hydrocarbons as well as chlorofluorocarbons (CFCs), carbon monoxide, ...

G. E. Moore; S. G. Douglas; R. C. Kessler; J. P. Killus

1991-05-01T23:59:59.000Z

137

NETL: Reference Shelf - Techline Archive  

NLE Websites -- All DOE Office Websites (Extended Search)

NETL Oil & Natural Gas Technologies Reference Shelf NETL Oil & Natural Gas Technologies Reference Shelf Archive Reports 2012: December, 2012 Final Project Report DE-NT0006554 GIS- and Web-based Water Resource Geospatial Infrastructure for Oil Shale Development [PDF-14.6MB] November, 2012 Final Project Report 08121-2902-02 Technologies of the Future for Pipeline Monitoring and Inspection [PDF-2.47MB] November, 2012 Final Project Report 07122-22 Petrophysical Studies of Unconventional Gas Reservoirs Using High-resolution Rock Imaging [PDF-27.7MB] November, 2012 Final Project Report 08122-35 The Environmentally Friendly Drilling Systems Program [PDF-4.33] October, 2012 Final Project Report DE-FE0003537 Next Generation Surfactants for Improved Chemical Flooding Technology [PDF-1.91MB] October, 2012 Final Project Report 08123-02 Field Demonstration of Alkaline Surfactant Polymer Floods in Mature Oil Reservoirs Brookshire Dome, Texas [PDF-5.06MB]

138

NPP References and Summaries  

NLE Websites -- All DOE Office Websites (Extended Search)

Full references and selected summaries (in alphabetical order of first author name by data set): Chinese Forests NPP Data Set References Gao, Q. and X.S. Zhang (1997) A simulation...

139

Standard Reference Data  

Science Conference Proceedings (OSTI)

... The National Standard Reference Data System (NSRDS-NBS) provides access to the quantitative data of physical sciences, critically evaluated ...

2013-09-19T23:59:59.000Z

140

Data center reference lists  

Science Conference Proceedings (OSTI)

Data Center Publications. Use the following form to retrieve a list of references to critical compilations, databases, reviews ...

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Standard Reference Materials  

Science Conference Proceedings (OSTI)

... Inn, KGW, Liggett, WS, and Hutchinson, JMR (1984), "The National Bureau of Standards Rocky Flats Soil Standard Reference Material," Nuclear ...

142

Wind Turbine Drivetrain Condition Monitoring - An Overview  

DOE Green Energy (OSTI)

This paper provides an overview of wind turbine drivetrain condition monitoring based on presentations from a condition monitoring workshop organized by the National Renewable Energy Laboratory in 2009 and on additional references.

Sheng, S; Veers, P.

2011-10-01T23:59:59.000Z

143

Chemical Reference Data Group Homepage  

Science Conference Proceedings (OSTI)

Chemical Reference Data Group. Welcome. The Chemical Reference Data Group compiles, evaluates, correlates and measures ...

2013-07-10T23:59:59.000Z

144

Workshop on indoor air quality research needs  

Science Conference Proceedings (OSTI)

Workshop participants report on indoor air quality research needs including the monitoring of indoor air quality, report of the instrumentation subgroup of indoor air quality, health effects, and the report of the control technology session. Risk analysis studies addressing indoor environments were also summarized. (DLS)

Not Available

1980-01-01T23:59:59.000Z

145

International Energy Outlook - Chapter References  

Gasoline and Diesel Fuel Update (EIA)

Chapter References Chapter References International Energy Outlook 2004 Chapter References World Energy and Economic Outlook 1. D.F. Barnes et al., “Tackling the Rural Energy Problem in Developing Countries,” Finance & Development, Vol. 34, No. 2 (June 1997), pp. 11-15. 2. A. Kirby, “Russia’s Climate Tussle Spins On,” BBC News Online (December 4, 2003). 3. A.C. Revkin, “Into Thin Air: Kyoto Accord May Not Die (or Matter),” The New York Times (December 4, 2003), p. A6. 4. The White House, Office of the Press Secretary, “President Announces Clear Skies & Global Climate Change Initiatives” (Press Release, February 14, 2002), web site www.whitehouse.gov/news/ releases/2002/02/20020214-5.html. 5. Energy Information Administration, Annual Energy Outlook 2004, DOE/EIA-0383(2004) (Washington, DC, January 2004); and Global Insight, Inc., World Overview (Lexington, MA, September 2003). India’s GDP growth rates were adjusted downward, based on the judgment of EIA analysts.

146

Ga Air Compressor, Ga Air Compressor Products, Ga Air ...  

U.S. Energy Information Administration (EIA)

Ga Air Compressor, You Can Buy Various High Quality Ga Air Compressor Products from Global Ga Air Compressor Suppliers and Ga Air Compressor ...

147

ITS 1.5 Reference Manual  

E-Print Network (OSTI)

This reference manual consists of two parts. The first (sections 1 through 6) is intended for those who are either interested in the ITS 1.5 time sharing monitor for its own sake or who wish to write machine language ...

Eastlake, D.

1969-07-01T23:59:59.000Z

148

ITS 1.5 Reference Manual  

E-Print Network (OSTI)

This reference manual consists of two parts. The first (sections 1 through 6) is intended for those who are either interested in the ITS 1.5 time sharing monitor for its own sake or who wish to write machine language ...

Eastlake, D.

1968-06-01T23:59:59.000Z

149

High frequency reference electrode  

DOE Patents (OSTI)

A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or halo'' at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes.

Kronberg, J.W.

1991-03-05T23:59:59.000Z

150

High frequency reference electrode  

DOE Patents (OSTI)

A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or halo' at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes. 4 figs.

Kronberg, J.W.

1994-05-31T23:59:59.000Z

151

High frequency reference electrode  

DOE Patents (OSTI)

A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or "halo" at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes.

Kronberg, James W. (Aiken, SC)

1994-01-01T23:59:59.000Z

152

Engineering Task Plan for Standard Hydrogen Monitoring System Operation  

DOE Green Energy (OSTI)

Tanks that are known or suspected to retain and occasionally release flammable gases are equipped with Standard Hydrogen Monitoring System (SHMS) cabinets. These cabinets contain Whittaker{trademark} electrochemical cells and may also have a gas chromatograph (GC) and/or a Bruel and Kjaer infrared photo-acoustic multi-gas monitor (B&K). The GC and B&K will be referred to collectively as ''analytical instruments'' in this document. Using these instruments, a tank can be monitored for hydrogen, helium, ammonia, methane, and nitrous oxide. Air from the tank vent header (for actively ventilated tanks) or dome space (for passively ventilated tanks) is drawn continuously through the monitoring instruments via a sample pump. This monitoring is performed to track the gas release behavior of selected waste storage tanks and to help identify any potentially serious gas release behavior. Vapor grab samples may be obtained from the SHMS as well and analyzed with a mass spectrometer to obtain concentration data about hydrogen and other gases. This document describes the requirements for the operation, maintenance, calibration, and data collection for the Standard Hydrogen Monitoring System. Additionally, this document defines who is responsible for the various tasks.

MCCAIN, D.J.

1999-11-11T23:59:59.000Z

153

Best practice techniques for environmental radiological monitoring  

E-Print Network (OSTI)

/Medium Volume Air Sampling (HVAS/MVAS). #12;Science Report Best Practice Techniques for Environmental Community FSA: Food Standards Agency H2O2: Hydrogen peroxide HPA: Health Protection Agency HVAS/MVAS: High/monitoring type code Terrestrial dose rate monitoring T1 Air passive shades and HVAS/MVAS T2 Wet, dry, total

154

Optical voltage reference  

DOE Patents (OSTI)

An optical voltage reference for providing an alternative to a battery source. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function.

Rankin, R.; Kotter, D.

1992-12-31T23:59:59.000Z

155

Optical voltage reference  

DOE Patents (OSTI)

An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

Rankin, R.; Kotter, D.

1994-04-26T23:59:59.000Z

156

Monitoring Jobs on Hopper  

NLE Websites -- All DOE Office Websites (Extended Search)

Monitoring Jobs Monitoring Jobs Monitoring Jobs Monitoring Edison Batch Jobs The batch system provides the command to monotor your jobs. We are listing the commands commonly used to submit and monitor the jobs. For more informaiton please refer to the man pages of these commands. Job Commands Command Description qsub batch_script Submits batch script to the queue. The output of qsub will be a jobid qdel jobid Deletes a job from the queue qhold jobid Puts a job on hold in the queue. qrls jobid Releases a job from hold. qalter [options] jobid Change attributes of submitted job. (See below.) qmove new_queue jobid Move job to new queue. Remember, the new queue must be one of the submission queues (premium, regular, or low) qstat -a Lists jobs in submission order (more useful than qstat without options) Also takes -u and -f [jobid]> options

157

APPENDIX B: REFERENCES  

NLE Websites -- All DOE Office Websites (Extended Search)

2010 Appendix B: References Bloomfield, K., J.N. Moore, and R.M. Neilson Jr. 2003. Geothermal Energy Reduces Greenhouse Gases. Geothermal Research Council. GRC Bulletin, April...

158

The Conniver Reference Manual  

E-Print Network (OSTI)

This manual is an introduction and reference to the latest version of the Conniver programming language, an AI language wit general control and data-base structures.

McDermott, Drew V.

1972-05-01T23:59:59.000Z

159

NEWTON's References About Mathematics  

NLE Websites -- All DOE Office Websites (Extended Search)

Please click our Ideas page. Featured Reference Links: Free Math Video Lectures Mathematics Online Courses View 100s of free instructional math videos. FreeVideoLectures...

160

Device for monitoring cell voltage  

SciTech Connect

A device for monitoring a rechargeable battery having a number of electrically connected cells includes at least one current interruption switch for interrupting current flowing through at least one associated cell and a plurality of monitoring units for detecting cell voltage. Each monitoring unit is associated with a single cell and includes a reference voltage unit for producing a defined reference threshold voltage and a voltage comparison unit for comparing the reference threshold voltage with a partial cell voltage of the associated cell. The reference voltage unit is electrically supplied from the cell voltage of the associated cell. The voltage comparison unit is coupled to the at least one current interruption switch for interrupting the current of at least the current flowing through the associated cell, with a defined minimum difference between the reference threshold voltage and the partial cell voltage.

Doepke, Matthias (Garbsen, DE); Eisermann, Henning (Edermissen, DE)

2012-08-21T23:59:59.000Z

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

NEWTON's Botany References  

NLE Websites -- All DOE Office Websites (Extended Search)

Botany References Botany References Do you have a great botany reference link? Please click our Ideas page. Featured Reference Links: Dave's Garden - Plant Database Dave's Garden - Plant Database Visit Dave's Garden with information and photos for 185,359 different plants! United States Department of Agriculture Plant Database USDA PLANTS Database The PLANTS Database provides standardized information about the vascular plants, mosses, liverworts, hornworts, and lichens of the U.S. and its territories. Search over 40,000 plant images of US plants. Botany.com Botany.com Botany.com offers an encyclopedia of flowers and plants and resources to help people learn how to identify any different kinds of plants. Plant Kingdom This is a good reference for looking at the plant kingdom.

162

NEWTON's General Science References  

NLE Websites -- All DOE Office Websites (Extended Search)

General Science References General Science References Do you have a great general science reference link? Please click our Ideas page. Featured Reference Links: First.gov Science and Technology First.gov Science and Technology This site, sponsered by the US Government provides reference links to topics on science, telecommunications, computers, research agencies, and news. NASA Science NASA Science NASA Science, is a website sponsered by NASA, that supplies resources for understanding our world and the world above. Topics include earth science, heliophysics, the planets, astrophysics and much more. There is also an educator page! Nobel Laueate Listings and Stories Nobel Laueate Listings and Stories See the official site for the Nobel Prize, and read biographies about all of the Nobel Laureates, and there life changing discoveries and accomplishments.

163

Compressed Air 101: Getting Compressed Air to Work  

E-Print Network (OSTI)

"Air compressors are a significant industrial energy user. Based on a survey (conducted by Oregon State University and the Bonneville Power Administration) of energy audit reports from 125 plants, air compressors account for roughly 10% of total plant energy use. Furthermore, air compression is inefficient with up to 95% of compressor power dissipated as heat. Thus even minor improvements in system operation, control strategies, and efficiency can yield large energy savings and significant non-energy or productivity benefits from reliable compressed air. Compressed air is often called the ""fourth utility"" in industrial facilities after electricity, natural gas, and water. It provides motive power for machinery, cooling, materials handling, and hand tools. It is a safe, flexible, and powerful resource, but one that is seldom run for low operating costs or best productivity. Learning the basics of compressed air systems represents the beginning of both reducing energy costs and enjoying the productive benefits of reliable compressed air. Compressed air management systems, including a system approach to managing demand, stabilizing pressure, reducing leaks and compressor controls, can allow the industrial end user to save 20% - 50% of their air compressor electricity usage. The monitoring capabilities of compressed air management systems provide a useful tool through power, pressure and flow trending to maintain both the energy savings and increased system reliability. More efficiently managed compressed air systems are less costly to maintain and have less impact on the environment. The most important issues of industrial compressed air in relation to energy efficiency and management are: 1. Compressed air is an essential industrial utility; 2. Compressing air is a fundamentally inefficient energy transformation process; 3. Optimal operation of compressed air systems in industrial plants is seldom a priority and adequate management infonnation is rare, resulting in negative impacts on production and even less efficiency."

Burke, J. J.; Bessey, E. G.

2003-05-01T23:59:59.000Z

164

NISTIR 6458 Characterization of the Inlet Combustion Air in  

E-Print Network (OSTI)

NISTIR 6458 Characterization of the Inlet Combustion Air in NIST's Reference Spray Combustion January 2000 #12;ii Contents page Introduction 1 Reference Spray Combustion Facility 3 Numerical;1 Characterization of the Inlet Combustion Air in NIST's Reference Spray Combustion Facility: Effect of Vane Angle

Magee, Joseph W.

165

Wilderness Preservation : a Reference Handbook  

E-Print Network (OSTI)

Preservation: A Reference Handbook By Kenneth A. RossenbergPreservation: A Reference Handbook. Santa Barbara: ABC-CLIO,Preservation: A Reference Handbook is a comprehensive

Zimmer, Peter

1996-01-01T23:59:59.000Z

166

FY 2002 Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project  

SciTech Connect

This document is an integrated monitoring plan for the groundwater project and contains: well and constituent lists for monitoring required by the Atomic Energy Act of 1954 and its implementing orders (''surveillance monitoring''); other, established monitoring plans by reference; and a master well/ constituent/frequency matrix for the entire Hanford Site.

Hartman, Mary J; Dresel, P Evan; Lindberg, Jon W; Newcomer, Darrell R; Thornton, Edward C

2001-10-31T23:59:59.000Z

167

FY 2002 Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project  

SciTech Connect

This document is an integrated monitoring plan for the groundwater project and contains: well and constituent lists for monitoring required by the Atomic Energy Act of 1954 and its implementing orders ("surveillance monitoring"); other, established monitoring plans by reference; and a master well/ constituent/frequency matrix for the entire Hanford Site.

Hartman, Mary J.; Dresel, P Evan; Lindberg, Jonathan W.; Newcomer, Darrell R.; Thornton, Edward C.

2001-10-31T23:59:59.000Z

168

NETL: Oil & Natural Gas Technologies Reference Shelf - Presentation  

NLE Websites -- All DOE Office Websites (Extended Search)

Mapping Study to Characterize NSCR Performance on a Natural Gas-Fueled Engine Mapping Study to Characterize NSCR Performance on a Natural Gas-Fueled Engine Mapping Study to Characterize NSCR Performance on a Natural Gas-Fueled Engine Authors: Mohamed Toema (speaker), Sarah Nuss-Warren, and Kirby S. Chapman, Kansas State University National Gas Machinery Laboratory; James McCarthy and Thomas McGrath, Innovative Environmental Solutions Inc. Venue: ASME Internal Combustion Engine Division 2009 Spring Technical Conference, May 3–6, Milwaukee, WI. http://www.asmeconferences.org/ICES09/index.cfm [external site]. Abstract: The researchers are conducting a project to characterize pollutant emissions performance of field gas-fired four-stroke cycle rich burn engines equipped with non-selective catalytic reduction (NSCR) technology. Engine emissions and operating parameters are being monitored on three engines over an extended period. In addition, a mapping study was conducted on one engine. The NSCR was operated at various controlled air-to-fuel (AF) ratios while emission measurements were conducted and engine operating parameters monitored. NOx, CO, and oxygen were measured using both EPA reference method technology and the portable analyzer used in the long-term study. In the mapping study, ammonia, formaldehyde, CO, NOx, and speciated hydrocarbon emissions were recorded in real-time using an extractive FTIR system. This paper focuses on the engine mapping phase. The mapping tests demonstrated a trade-off between NOx emissions and CO, ammonia, and hydrocarbon emissions. Richer engine operation (lower AF) decreases NOx emissions at the expense of higher CO, ammonia, and hydrocarbons. Leaner operation has the opposite effect. The results to date of the semi-continuous monitoring are presented in a separate paper.

169

DUS II SOIL GAS SAMPLING AND AIR INJECTION TEST RESULTS  

Science Conference Proceedings (OSTI)

Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected VOC soil gas concentrations during ASVE. Five (5) SVE wells that were located closest to the air injection wells were used as monitoring points during the air sparging tests. The air sparging tests lasted 48 hours. Soil gas sample results indicate that sparging did not affect VOC concentrations in four of the five sparging wells, while results from one test did show an increase in soil gas concentrations.

Noonkester, J.; Jackson, D.; Jones, W.; Hyde, W.; Kohn, J.; Walker, R.

2012-09-20T23:59:59.000Z

170

A New Method for Calibrating Reference and Field Pyranometers  

Science Conference Proceedings (OSTI)

A simple method for calibrating reference pyranometers is described. Called the alternate method, it requires monitoring of direct irradiance and diffuse and global irradiance voltages without the need for a calibrated diffuse pyranometer. The ...

Bruce W. Forgan

1996-06-01T23:59:59.000Z

171

Environmental monitoring at Argonne National Laboratory. Annual report for 1983  

Science Conference Proceedings (OSTI)

The results of the environmental monitoring program at Argonne National Laboratory for 1983 are presented and discussed. To evaluate the effect of Argonne operations on the environment, measurements were made for a variety of radionuclides in air, surface water, soil, grass, bottom sediment, and milk; for a variety of chemical constituents in air, surface water, ground water, and Argonne effluent water; and of the environmental penetrating radiation dose. Sample collections and measurements were made at the site boundary and off the Argonne site for comparison purposes. Some on-site measurements were made to aid in the interpretation of the boundary and off-site data. The potential radiation dose to off-site population groups is also estimated. The results of the program are interpreted in terms of the sources and origin of the radioactive and chemical substances (natural, fallout, Argonne, and other) and are compared with applicable environmental quality standards. 19 references, 8 figures, 49 tables.

Golchert, N.W.; Duffy, T.L.; Sedlet, J.

1984-03-01T23:59:59.000Z

172

Continuous Air Monitor Operating Experience Review  

Science Conference Proceedings (OSTI)

Tritium, Safety, and Environment / Eighteenth Topical Meeting on the Technology of Fusion Energy (Part 1)

L. C. Cadwallader; S. A. Bruyere

173

Beta/alpha continuous air monitor  

DOE Patents (OSTI)

A single deep layer silicon detector in combination with a microcomputer, recording both alpha and beta activity and the energy of each pulse, distinquishing energy peaks using a novel curve fitting technique to reduce the natural alpha counts in the energy region where plutonium and other transuranic alpha emitters are present, and using a novel algorithm to strip out radon daughter contribution to actual beta counts. 7 figs.

Becker, G.K.; Martz, D.E.

1988-06-27T23:59:59.000Z

174

Air Pollution Control (Oklahoma) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Pollution Control (Oklahoma) Air Pollution Control (Oklahoma) Air Pollution Control (Oklahoma) < Back Eligibility Agricultural Fuel Distributor Industrial Investor-Owned Utility Local Government Municipal/Public Utility Rural Electric Cooperative State/Provincial Govt Systems Integrator Tribal Government Utility Savings Category Buying & Making Electricity Program Info State Oklahoma Program Type Environmental Regulations Provider Environmental Quality This chapter enumerates primary and secondary ambient air quality standards and the significant deterioration increments. Significant deterioration refers to an increase in ambient air pollution above a baseline plus a specific increment allowed for one of three classes of areas. It is required for potential sources of air contaminants to register with the

175

References to Astrophysics Papers  

NLE Websites -- All DOE Office Websites (Extended Search)

References to Astrophysics Papers References to Astrophysics Papers References to Astrophysics Papers Edward Tufte claims the most common number of references to scientific papers is zero. My five papers in astrophysics published from 1992 to 1996 continue to receive citations. Major ones are listed below. Mineo, S.; Rappaport, S.; Steinhorn, B.; Levine, A.; Gilfanov, M.; Pooley, D., 2013, The Astrophysical Journal, Volume 771, Issue 2, article id. 133, 12 pp. Spatially Resolved Star Formation Image and the Ultraluminous X-Ray Source Population in NGC 2207/IC 2163 Junqueira, T. C.; Lépine, J. R. D.; Braga, C. A. S.; Barros, D. A 2013, Astronomy & Astrophysics, Volume 550, id.A91. A new model for gravitational potential perturbations in disks of spiral galaxies. An application to our Galaxy.

176

NEWTON's References About Mathematics  

NLE Websites -- All DOE Office Websites (Extended Search)

Math References Math References Do you have a great math reference link? Please click our Ideas page. Featured Reference Links: Steve Marsden's Chemistry Resources Discovery Education's Mathematics Guide Discovery Educators have provided a Mathematics Guide for Educators. Included are numerous links to sites that touch on almost every mathematic topic that you are interested in. The Ultimate Math Portal The Ultimate Math Portal Whether you are confused by multiplication, need extra practice with geometry proofs, find yourself struggling to understand logarithms, or you just want to know more about pi, you are sure to find what you need with this great list of math facts and resources. MathIsFun.com MathIsFun.com Here, math is explained in easy language, for your students to understand. Plus, there are puzzles, games, quizzes, worksheets and a forum for more exploration. This site is designed for K-12 kids, teachers and parents to enjoy.

177

NEWTON's Material Science References  

NLE Websites -- All DOE Office Websites (Extended Search)

Material Science References Material Science References Do you have a great material science reference link? Please click our Ideas page. Featured Reference Links: Materials Research Society Materials Research Society The Materials Research Society has assembled many resources in its Materials Science Enthusiasts site. This site has information for the K-12 audience, general public, and materials science professionals. Material Science nanoHUB nanHUB.org is the place for nanotechnology research, education, and collaboration. There are Simulation Programs, Online Presentations, Courses, Learning Modules, Podcasts, Animations, Teaching Materials, and more. (Intened for high school and up) Materials Science Resources on the Web Materials Science Resources on the Web This site gives a good general introduction into material science. Sponsered by Iowa State, it talks about what material science is, ceramics and composites, and other topics.

178

NEWTON's Molecular Biology References  

NLE Websites -- All DOE Office Websites (Extended Search)

Molecular Biology References Molecular Biology References Do you have a great reference link? Please click our Ideas page. Featured Reference Links: The Vitual Museum of Bacteria The Vitual Museum of Bacteria Visit the virtual museum of bacteria to learn more about bacteria and germs! This site brings together many links on bacteria, bacteriology, and related topics available on the web. It also provides crystal-clear information about many aspects of bacteria. The American Society of Cell Biology Cell Biology Educational Resources This site, sponsered by the American Society of Cell Biology, provides additional web links to everything from, general educational sites, to biology course materials, to teaching tools and more. National Center for Biotechnology Information National Center for Biotechnology Information

179

Transforming Definitions of Reference  

E-Print Network (OSTI)

“Four components of reference service: 1. Instruct the reader in the ways of the library. 2. Assist readers in solving their inquiries. 3. Aid the reader in the selection of good works. 4. Promote the library within the community.” Green, S.S. (1876). Personal relations between librarian and readers. American Library Journal, 1, 74-81. 1943 “Reference work. 1. That phase of library work which is directly concerned with assistance to readers in securing information and in using the resources of the library in study and research. 2. The work of a reference department.” American Library Association. Committee on Library Terminology. (1943). A.L.A. glossary of library terms, with a selection of terms in related fields. Chicago: American Library Association. 1982 “Reference transaction An information contact which involves the use, recommendation, interpretation, or instruction in the use of one or more information sources, or knowledge of such

unknown authors

2008-01-01T23:59:59.000Z

180

References - Energy Information Administration  

U.S. Energy Information Administration (EIA)

References 1.En ergy In for ma tion Ad min istra tion. Natu ral Gas Pro - duc tive Ca pac ity for the Lower 48 States 1980 through 1991 . DOE/EIA- 0542 (Wash ing ton ...

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

LLSIM Reference Manual  

E-Print Network (OSTI)

A program that simulates a Digital Equipment Corporation PDP-11 computer and many of its peripherals on the AI Laboratory Time Sharing System (ITS) is described from a user's reference point of view. This simulator has ...

Eastlake, Donald

1971-12-01T23:59:59.000Z

182

MIT Scheme Reference Manual  

E-Print Network (OSTI)

MIT Scheme is an implementation of the Scheme programming language that runs on many popular workstations. The MIT Scheme Reference Manual describes the special forms, procedures, and datatypes provided by the ...

Hanson, Chris

1991-01-01T23:59:59.000Z

183

LLSIM Reference Manual  

E-Print Network (OSTI)

A program that simulates a Digital Equipment Corporation PDP-11 computer and many of its peripherals on the AI Laboratory Time Sharing System (ITS) is described from a user's reference point of view. This simulator has ...

Eastlake, Donald E.

1972-02-01T23:59:59.000Z

184

Technical Reference OVERVIEW  

NLE Websites -- All DOE Office Websites (Extended Search)

and the ENERGY STAR Score in the United States and Canada Page 1 Parking and the ENERGY STAR Score in the United States and Canada Technical Reference OVERVIEW The ENERGY STAR...

185

• Temperature Compensated ReferenceMonitors 3.0 V (MC34164–3) or 5.0 V (MC34164–5) Power Supplies • Precise Comparator Thresholds Guaranteed Over Temperature • Comparator Hysteresis Prevents Erratic Reset • Reset Output Capable of Sinking in Excess of  

E-Print Network (OSTI)

The MC34164 series are undervoltage sensing circuits specifically designed for use as reset controllers in portable microprocessor based systems where extended battery life is required. These devices offer the designer an economical solution for low voltage detection with a single external resistor. The MC34164 series features a bandgap reference, a comparator with precise thresholds and built–in hysteresis to prevent erratic reset operation, an open collector reset output capable of sinking in excess of 6.0 mA, and guaranteed operation down to 1.0 V input with extremely low standby current. These devices are packaged in 3–pin TO–226AA, 8–pin SO–8 and Micro8? surface mount packages. Applications include direct monitoring of the 3.0 or 5.0 V MPU/logic power supply used in appliance, automotive, consumer, and industrial equipment.

Micro Surface; Mount Packages

2001-01-01T23:59:59.000Z

186

Engineering task plan for standard hydrogen monitoring system operation  

DOE Green Energy (OSTI)

Tanks that are known or suspected to retain and occasionally release flammable gases are equipped with Standard Hydrogen Monitoring System (SHMS) cabinets. These cabinets contain Whittaker{trademark} electrochemical cells and may also have a gas chromatograph (GC) and/or a Bruel and Kjaer infrared photo-acoustic multi-gas monitor (B and K). The GC and B and K will be referred to collectively as ''analytical instruments'' in this document. Using these instruments, a tank can be monitored for hydrogen, ammonia, methane, and nitrous oxide. Air from the tank vent header (for actively ventilated tanks) or dome space (for passively ventilated tanks) is drawn continuously through the monitoring instruments via a sample pump. This monitoring is performed to track the gas release behavior of selected waste storage tanks and to help identify any potentially serious gas release behavior. Vapor grab samples are obtained from the SHMS as well and are analyzed with a mass spectrometer to obtain concentration data about hydrogen and other gases.

MCCAIN, D.J.

1999-06-02T23:59:59.000Z

187

Case Study 12 - Airflow and Indoor Air Quality Models of DOE ...  

Science Conference Proceedings (OSTI)

... Air Quality Models of DOE Reference Commercial Buildings. ... are intended to simultaneously reduce building energy consumption while maintaining ...

188

Dynamic Control of Lab Air Change Rates using Multiplexed IEQ...  

NLE Websites -- All DOE Office Websites (Extended Search)

commissioning. This presentation discusses a new type of real time, multiplexed facility monitoring technology. Packets of air and data are routed through a unique, hollow...

189

Air Products Chemicals Inc | Open Energy Information  

Open Energy Info (EERE)

Air Products Chemicals Inc Air Products Chemicals Inc Jump to: navigation, search Name Air Products & Chemicals Inc Place Allentown, Pennsylvania Zip 18195 Sector Hydro, Hydrogen, Services Product A global supplier of merchant hydrogen with a portfolio of products, services and solutions providing gases, performance materials and chemical intermediates. References Air Products & Chemicals Inc[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Air Products & Chemicals Inc is a company located in Allentown, Pennsylvania . References ↑ "Air Products & Chemicals Inc" Retrieved from "http://en.openei.org/w/index.php?title=Air_Products_Chemicals_Inc&oldid=341937

190

Clean Air Act | Open Energy Information  

Open Energy Info (EERE)

Clean Air Act Clean Air Act Jump to: navigation, search Statute Name Clean Air Act Year 1970 Url CAA.jpg Description Congress passed the CAA in 1970 in order to combat air pollution in the United States and protect the health and general welfare of United States citizens against air pollutants. References CAA[1] Federal Oil and Gas[2] Contents 1 Introduction 2 Title I Air Pollution Prevention 3 Title II Emission Standards for Moving Sources 4 Title III General Provisions 5 Title IV Acid Deposition Control 6 Title V Permits 7 Title VI Stratospheric Ozone Protection 8 References Introduction The Clean Air Act was enacted by congress in 1990. Since then only minor changes have been made. The act is just a law ensuring that the EPA will follow certain guidelines and definitions for protecting and improving the

191

Overview of Strategies for Making Connections Between Transportation, Land Use and Air Quality  

E-Print Network (OSTI)

Land Use Regulation : Designing Parking Policies to Reduce Automotive PollutionLand Use, Air Quality Connection deals with the mobile monitoring of pollutionLand Use, Air Quality Connection The Comprehensive Behavior Alternative approach views air pollution

Shirazi, Elham; Taylor, Brian

2004-01-01T23:59:59.000Z

192

Clean Air Act. Revision 5  

SciTech Connect

This Reference Book contains a current copy of the Clean Air Act, as amended, and those regulations that implement the statute and appear to be most relevant to DOE activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. This Reference Book has been completely revised and is current through February 15, 1994.

Not Available

1994-02-15T23:59:59.000Z

193

Multizone infiltration monitoring system  

DOE Green Energy (OSTI)

A multizone infiltration monitoring system (MIMS) using a single tracer gas has been developed. MIMS measures zonal infiltration and exfiltration as well as interzonal air movement rates. The system has been used at the 4-zone test house at the SERI interim field site, and this paper presents preliminary results. The present system can determine zonal infiltration rates, and the results show significant differences in infiltration rates for the various zones.

Wortman, D.N.; Burch, J.; Judkoff, R.

1982-06-01T23:59:59.000Z

194

Colorado Air Pollutant Emission Notice (APEN) Form | Open Energy...  

Open Energy Info (EERE)

Form Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Reference Material: Colorado Air Pollutant Emission Notice (APEN) Form Details Activities (0) Areas (0) Regions...

195

Colorado Construction Air Permit Application | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Reference Material: Colorado Construction Air Permit Application Details Activities (0) Areas (0) Regions (0)...

196

Quality Assurance REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Quality Assurance Quality Assurance Qualification Standard DOE-STD-1150-2002 July 2012 Reference Guide The Functional Area Qualification Standard References Guides are developed to assist operators, maintenance personnel, and the technical staff in the acquisition of technical competence and qualification within the Technical Qualification Program. Please direct your questions or comments related to this document to the Office of Leadership and Career Management, Technical Qualification Program (TQP) Manager, Albuquerque Complex. This page is intentionally blank. Table of Contents i FIGURES ....................................................................................................................................... ii TABLES ........................................................................................................................................ iii

197

Multifunctional reference electrode  

DOE Patents (OSTI)

A multifunctional, low mass reference electrode of a nickel tube, thermocouple means inside the nickel tube electrically insulated therefrom for measuring the temperature thereof, a housing surrounding the nickel tube, an electrolyte having a fixed sulfide ion activity between the housing and the outer surface of the nickel tube forming the nickel/nickel sulfide/sulfide half-cell are described. An ion diffusion barrier is associated with the housing in contact with the electrolyte. Also disclosed is a cell using the reference electrode to measure characteristics of a working electrode.

Redey, L.; Vissers, D.R.

1981-12-30T23:59:59.000Z

198

TERMS OF REFERENCE  

E-Print Network (OSTI)

Act 2002 (the Act), hereby makes a reference to the CC for an investigation into the supply or acquisition of PH in the UK. 2. The OFT has reasonable grounds for suspecting that a feature or a combination of features of the market or markets for the supply or acquisition of PH prevents, restricts or distorts competition. 3. For the purposes of this reference, PH means privately funded healthcare services. These are services provided to patients via private facilities/clinics including private patient units, through the services of consultants, medical and clinical

John Fingleton

2012-01-01T23:59:59.000Z

199

RADIATION MONITORING  

E-Print Network (OSTI)

of Monitoring for Radiation Protection of Workers" in ICRPNo. 9, in "Advances in Radiation Protection and Dosimetry inDosimetry f o r Stray Radiation Monitoring on the CERN S i t

Thomas, R.H.

2010-01-01T23:59:59.000Z

200

Grain Moisture Air-Oven Reference Methods in the United ...  

Science Conference Proceedings (OSTI)

... Sunflower ground 50/50 with celite None (for moisture cor? rection of crude oil results Icing Mix Powder Triticale ? 16 % Lasagna ...

2012-11-15T23:59:59.000Z

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Environmental Monitoring Plan: Environmental Monitoring Section. Appendix A, Procedures  

Science Conference Proceedings (OSTI)

This document presents information about the environmental monitoring program at Lawrence Livermore National Laboratory. Topics discussed include: air sampling; air tritium calibrations; storm water discharge; non-storm water discharge; sampling locations; ground water sampling; noise and blast forecasting; analytical laboratory auditing; document retention; procedure writing; quality assurance programs for sampling; soil and sediment sampling; sewage sampling; diversion facility tank sampling; vegetation and foodstuff sampling; and radiological dose assessments.

NONE

1995-02-01T23:59:59.000Z

202

High Efficiency Particulate Air Filters  

NLE Websites -- All DOE Office Websites (Extended Search)

High Efficiency Particulate Air (HEPA) Filters High Efficiency Particulate Air (HEPA) Filters Home Standards DOE Workshops Nuclear Air Cleaning Conference Proceedings Qualified Filter List News Items Related Sites HEPA Related Lessons Learned Contact Us HSS Logo High Efficiency Particulate Air Filters The HEPA Filter web site provides a forum for informing and reporting department-wide activities related to filtration and ventilation issues with special reference to the High Efficiency Particulate Air (HEPA) Filters' use, inspection, and testing. This site contains essentials of DOE HEPA filter test program, procedures, requirements and quality assurance aspects applicable to HEPA filters used in DOE facilities. This site contains information about the DOE-accepted Filter Test Facility and its management, operation and quality assuranceprogram.

203

Radwaste Desk Reference  

Science Conference Proceedings (OSTI)

This volume of the Radwaste Desk Reference contains fundamental practical and regulatory information on the transportation of radioactive waste. Because its information is based entirely on industry practice, the work can serve as an extensive how-to manual for both the newcomer and the experienced radwaste professional.

2011-07-28T23:59:59.000Z

204

EPRI HVDC Reference Book  

Science Conference Proceedings (OSTI)

This report is actually Chapter 17 of the EPRI HVDC Reference Book and describes a variety of simulation tools for high-voltage direct current (HVDC) systems. Modeling and simulation of HVDC systems is essential in the planning, engineering, designing, and operating stages of an HVDC system.

2008-04-15T23:59:59.000Z

205

AltAir Fuels | Open Energy Information  

Open Energy Info (EERE)

Sector Renewable Energy Product Seattle-based developer of projects for the production of jet fuel from renewable and sustainable oils. References AltAir Fuels1 LinkedIn...

206

Overview - WIPP Effluent Monitoring  

NLE Websites -- All DOE Office Websites (Extended Search)

Overview of the WIPP Effluent Monitoring Program Compliance with Title 40 CFR Part 191, Subpart A Environmental Standards for Management and Storage L. Frank-Supka, D. J. Harward, S. C. Casey May 2005 INTRODUCTION This document provides an overview of the effluent air monitoring activities at the Waste Isolation Pilot Plant (WIPP), in Carlsbad, New Mexico. The WIPP Effluent Monitoring Program is designed to comply with the U.S. Environmental Protection Agency (EPA) radiation protection standards for management and storage of spent nuclear fuel, high-level radioactive waste and transuranic (TRU)-waste at the WIPP. The standards issued by the EPA are contained in Title 40 Code of Federal Regulations (CFR), Part 191, Subpart A. The standards require the

207

Positional reference system for ultraprecision machining  

DOE Patents (OSTI)

A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of position interferometers and part contour description data inputs to calculate error components for each axis of movement and output them to corresponding axis drives with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

Arnold, Jones B. (Knoxville, TN); Burleson, Robert R. (Clinton, TN); Pardue, Robert M. (Knoxville, TN)

1982-01-01T23:59:59.000Z

208

Positional reference system for ultraprecision machining  

DOE Patents (OSTI)

A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of positions interferometers and part contour description data input to calculate error components for each axis of movement and output them to corresponding axis driven with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

1980-09-12T23:59:59.000Z

209

Idaho National Laboratory Environmental Monitoring Plan  

SciTech Connect

This plan describes environmental monitoring as required by U.S. Department of Energy (DOE) Order 450.1, “Environmental Protection Program,” and additional environmental monitoring currently performed by other organizations in and around the Idaho National Laboratory (INL). The objective of DOE Order 450.1 is to implement sound stewardship practices that protect the air, water, land, and other natural and cultural resources that may be impacted by DOE operations. This plan describes the organizations responsible for conducting environmental monitoring across the INL, the rationale for monitoring, the types of media being monitored, where the monitoring is conducted, and where monitoring results can be obtained. This plan presents a summary of the overall environmental monitoring performed in and around the INL without duplicating detailed information in the various monitoring procedures and program plans currently used to conduct monitoring.

Joanne L. Knight

2008-04-01T23:59:59.000Z

210

Idaho National Laboratory Site Environmental Monitoring Plan  

SciTech Connect

This plan describes environmental monitoring as required by U.S. Department of Energy (DOE) Order 450.1, “Environmental Protection Program,” and additional environmental monitoring currently performed by other organizations in and around the Idaho National Laboratory (INL). The objective of DOE Order 450.1 is to implement sound stewardship practices that protect the air, water, land, and other natural and cultural resources that may be impacted by DOE operations. This plan describes the organizations responsible for conducting environmental monitoring across the INL, the rationale for monitoring, the types of media being monitored, where the monitoring is conducted, and where monitoring results can be obtained. This plan presents a summary of the overall environmental monitoring performed in and around the INL without duplicating detailed information in the various monitoring procedures and program plans currently used to conduct monitoring.

Joanne L. Knight

2012-08-01T23:59:59.000Z

211

Idaho National Laboratory Site Environmental Monitoring Plan  

Science Conference Proceedings (OSTI)

This plan describes environmental monitoring as required by U.S. Department of Energy (DOE) Order 450.1, “Environmental Protection Program,” and additional environmental monitoring currently performed by other organizations in and around the Idaho National Laboratory (INL). The objective of DOE Order 450.1 is to implement sound stewardship practices that protect the air, water, land, and other natural and cultural resources that may be impacted by DOE operations. This plan describes the organizations responsible for conducting environmental monitoring across the INL, the rationale for monitoring, the types of media being monitored, where the monitoring is conducted, and where monitoring results can be obtained. This plan presents a summary of the overall environmental monitoring performed in and around the INL without duplicating detailed information in the various monitoring procedures and program plans currently used to conduct monitoring.

Joanne L. Knight

2010-10-01T23:59:59.000Z

212

Evaluation of Passive Monitors for Measuring Indoor Radon and Formaldehyde  

Science Conference Proceedings (OSTI)

Passive monitors for indoor air pollutants can furnish a cost-effective alternative to larger, more sophisticated, active monitors. In this study, three passive radon monitors provided sufficient accuracy and precision to support their use in utility measurement programs. However, the marginal performance of a passive formaldehyde monitor indicated the need for a vigorous quality assurance program to quantify its performance.

1988-12-01T23:59:59.000Z

213

NEWTON's Botany References  

NLE Websites -- All DOE Office Websites (Extended Search)

Botany References Botany References Do you have a great botany video? Please click our Ideas page. Featured Videos: AOL News AOL News - Botany Videos AOL news provides hundreds of botany videos from around the world. View informational and instructional videos as well as interviews about the latest botany topics and discoveries. NeoK12 Plant Videos NeoK12 - Every Plant Topic Imaginable Explore videos encompassing every category dealing with plants. Learn about photosynthesis, plant evolution, reproduction, and many more plant related videos. Fungus Image Fungi Videos BBC Nature provides informational videos about fugni and other organisms. Learn and explore a wide variety of topics concerning the fungus kingdom. Other Botany Videos: Botany Videos for Kids Look at various botany videos geared towards a younger audience.

214

Buenos Aires, Argentina: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Buenos Aires, Argentina: Energy Resources Buenos Aires, Argentina: Energy Resources Jump to: navigation, search Equivalent URI DBpedia GeoNames ID 3435910 This article is a stub. You can help OpenEI by expanding it. Buenos Aires is the capital of Argentina. Contents 1 Registered Networking Organizations in Buenos Aires, Argentina 2 Registered Policy Organizations in Buenos Aires, Argentina 3 Registered Energy Companies in Buenos Aires, Argentina 4 References Registered Networking Organizations in Buenos Aires, Argentina Asociacion Argentina de Energia Eolica Registered Policy Organizations in Buenos Aires, Argentina Proyecto de Energias Renovables en Mercados Rurales Registered Energy Companies in Buenos Aires, Argentina Dalkia Argentina References Retrieved from "http://en.openei.org/w/index.php?title=Buenos_Aires,_Argentina&oldid=270464"

215

NIST Standard Reference Simulation Website  

Science Conference Proceedings (OSTI)

... simulations, that can be treated similar to "standard reference data ... techniques and compiled by NIST under the Standards Reference Data Program. ...

2013-08-27T23:59:59.000Z

216

Reference Undulator Measurement Results  

SciTech Connect

The LCLS reference undulator has been measured 22 times during the course of undulator tuning. These measurements provide estimates of various statistical errors. This note gives a summary of the reference undulator measurements and it provides estimates of the undulator tuning errors. We measured the reference undulator many times during the tuning of the LCLS undulators. These data sets give estimates of the random errors in the tuned undulators. The measured trajectories in the reference undulator are stable and straight to within {+-}2 {micro}m. Changes in the phase errors are less than {+-}2 deg between data sets. The phase advance in the cell varies by less than {+-}2 deg between data sets. The rms variation between data sets of the first integral of B{sub x} is 9.98 {micro}Tm, and the rms variation of the second integral of B{sub x} is 17.4 {micro}Tm{sup 2}. The rms variation of the first integral of B{sub y} is 6.65 {micro}Tm, and the rms variation of the second integral of B{sub y} is 12.3 {micro}Tm{sup 2}. The rms variation of the x-position of the fiducialized beam axis is 35 {micro}m in the final production run This corresponds to an rms uncertainty in the K value of {Delta}K/K = 2.7 x 10{sup -5}. The rms variation of the y-position of the fiducialized beam axis is 4 {micro}m in the final production run.

Wolf, Z

2011-08-18T23:59:59.000Z

217

MATLAB r ? / R Reference  

E-Print Network (OSTI)

I wrote the first version of this reference during the Spring 2007 semester, as I learned R while teaching my course “MAT400, Modeling & Simulation ” at the University of Maine. The course covers population and epidemiological modeling, including deterministic and stochastic models in discrete and continuous time, along with spatial models. Half of the class meetings are in a regular classroom, and half are in a computer lab where students work through modeling & simulation exercises. When I taught earlier versions of the course, it was based on Matlab only. In Spring 2007, some biology graduate students in the class who had learned R in statistics courses asked if they could use R in my class as well, and I said yes. My colleague Bill Halteman was a great help as I frantically learned R to stay ahead of the class. As I went, every time I learned how to do something in R for the course, I added it to this reference, so that I wouldn’t forget it later. Some items took a huge amount of time searching for a simple way to do what I wanted, but at the end of the semester, I was pleasantly surprised that almost everything I do in Matlab had an equivalent in R. I was also inspired to do this after seeing the “R for Octave Users” reference written by Robin Hankin. This reference is organized into general categories. There is also a Matlab index and an R index at the end, which should make it easy to look up a command you know in one of the languages and learn

David Hiebeler

2008-01-01T23:59:59.000Z

218

Atmospheric CO2 From Flask Air Samples at 10 Sites in the SIO Air Sampling  

NLE Websites -- All DOE Office Websites (Extended Search)

Flask Air Samples, SIO Network Flask Air Samples, SIO Network Atmospheric CO2 From Flask Air Samples at 10 Sites in the SIO Air Sampling Network Scripps Institution of Oceanography Monitoring Sites Scripps Institution of Oceanography Monitoring Sites Mauna Loa, Hawaii Mauna Loa weekly average CO2 concentrations derived from continuous air samples Barrow, Alaska American Samoa South Pole Daily average CO2 concentrations derived from continuous air samples Alert, NWT, Canada Cape Kumukahi Christmas Island Baring Head Kermadec Island La Jolla Pier La Jolla Pier weekly average CO2 concentrations derived from continuous air samples PDF Documentation available as Atmospheric Carbon Dioxide Concentrations at 10 Locations Spanning Latitudes 82°N to 90°S, (NDP-001a) For information on calibration and some additional literature, go to

219

Reflred - Monitor  

Science Conference Proceedings (OSTI)

... power bumps due to weather conditions affecting the electrical supply), so use with caution. Be careful when mixing monitor and time data in the ...

220

Air Resources: Prevention and Control of Air Contamination and Air  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Resources: Prevention and Control of Air Contamination and Air Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York) Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York) < Back Eligibility Agricultural Fuel Distributor Industrial Institutional Investor-Owned Utility Local Government Multi-Family Residential Municipal/Public Utility Nonprofit Rural Electric Cooperative Schools State/Provincial Govt Transportation Tribal Government Utility Program Info State New York Program Type Environmental Regulations Provider NY Department of Environmental Conservation These regulations establish emissions limits and permitting and operational

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Prev'air: An Operational Forecasting and Mapping System for Air Quality in Europe  

Science Conference Proceedings (OSTI)

The current state of the art in three-dimensional chemistry-transport models allows them to be considered as mature and reliable enough to be combined with observations networks for implementing integrated air quality monitoring systems over ...

Laurence Rouil; Cécile Honoré; Bertrand Bessagnet; Laure Malherbe; Frédérik Meleux; Robert Vautard; Matthias Beekmann; Jean-Marie Flaud; Anne Dufour; Daniel Martin; Aline Peuch; Vincent-Henri Peuch; Christian Elichegaray; Nathalie Poisson; Laurent Menut

2009-01-01T23:59:59.000Z

222

A SURVEY OF INSTRUMENTATION USED FOR MONITORING METALS IN WATER  

E-Print Network (OSTI)

references. bJarrell -Ash, Instrumentation Lab . , Perkin£ sample, Jarrell-Ash, Instrumentation Labs. , Perkin Elmer,this room A Survey of Instrumentation Used for Monitoring

Quinby-Hunt, M.S.

2011-01-01T23:59:59.000Z

223

Coal data: A reference  

SciTech Connect

This report, Coal Data: A Reference, summarizes basic information on the mining and use of coal, an important source of energy in the US. This report is written for a general audience. The goal is to cover basic material and strike a reasonable compromise between overly generalized statements and detailed analyses. The section ``Supplemental Figures and Tables`` contains statistics, graphs, maps, and other illustrations that show trends, patterns, geographic locations, and similar coal-related information. The section ``Coal Terminology and Related Information`` provides additional information about terms mentioned in the text and introduces some new terms. The last edition of Coal Data: A Reference was published in 1991. The present edition contains updated data as well as expanded reviews and additional information. Added to the text are discussions of coal quality, coal prices, unions, and strikes. The appendix has been expanded to provide statistics on a variety of additional topics, such as: trends in coal production and royalties from Federal and Indian coal leases, hours worked and earnings for coal mine employment, railroad coal shipments and revenues, waterborne coal traffic, coal export loading terminals, utility coal combustion byproducts, and trace elements in coal. The information in this report has been gleaned mainly from the sources in the bibliography. The reader interested in going beyond the scope of this report should consult these sources. The statistics are largely from reports published by the Energy Information Administration.

Not Available

1995-02-01T23:59:59.000Z

224

Airlift mission monitoring and dynamic rescheduling  

Science Conference Proceedings (OSTI)

We describe the Flight Manager Assistant (FMA), a prototype system, designed to support real-time management of airlift operations at the USAF Air Mobility Command (AMC). In current practice, AMC flight managers are assigned to manage individual air ... Keywords: Collaboration, Dynamic schedule repair, Execution monitoring, Mediation, Scheduling

David E. Wilkins; Stephen F. Smith; Laurence A. Kramer; Thomas J. Lee; Timothy W. Rauenbusch

2008-03-01T23:59:59.000Z

225

Thermal storage HVAC system retrofit provides economical air conditioning  

Science Conference Proceedings (OSTI)

This article describes an EMS-controlled HVAC system that meets the ventilation and cooling needs of an 18,000-seat indoor ice hockey arena. The Buffalo Memorial Auditorium (affectionately referred to as the Aud) was built in 1937 under the Works Project Administration of the federal government. Its original configuration included a 12,000-seat arena with an ice skating rink. By the late 1980s, the city was unsuccessfully attempting to attract events and tenants to the auditorium, which lacked air conditioning and other modern amenities. Thus, it was decided to renovate the facility to make it marketable. The first phase of the renovation included installing an air-conditioning system in the arena and repairing the existing building systems that were inoperable because of deferred maintenance. After considering the existing conditions (such as size of the space, intermittent usage, construction restrictions, operating budgets and the limited operations staff), the engineering team designed an innovative HVAC system. The system's features include: a carbon dioxide monitoring device that controls the intake of outside air; an ice storage system that provides chilled water and shifts electrical demand to off-peak hours; and a design that uses the building mass as a heat sink. A new energy management system (EMS) determines building cooling needs based on the type of event, ambient conditions and projected audience size. Then, it selects the most economical method to obtain the desired arena temperature.

Smith, S.F. (Wendel Engineers, P.C., Buffalo, NY (United States))

1993-03-01T23:59:59.000Z

226

Air-Microfluidics: Towards Lab-on-a-Chip Systems for Low-Cost Air-Quality  

NLE Websites -- All DOE Office Websites (Extended Search)

Air-Microfluidics: Towards Lab-on-a-Chip Systems for Low-Cost Air-Quality Air-Microfluidics: Towards Lab-on-a-Chip Systems for Low-Cost Air-Quality Monitoring Speaker(s): Igor Paprotny Date: November 12, 2013 - 12:00pm - 1:00pm Location: 90-3122 Seminar Host/Point of Contact: Lara Gundel Air-microfluidic devices that monitor particles suspended in air, as opposed to liquids, can dramatically reduce the size and cost of future air-quality sensors. The use of microelectromechanical systems (MEMS) technologies and wafer-scale integration permits the inclusion of many different sensors onto a small footprint. Benefits of air-microfluidics are many. For example, air-microfluidic lab-on-a-chip devices can be used as portable sensors for tracking individual exposure to airborne pollutants. Such sensors will enable linking exposure and biometric information to

227

Technical Reference OVERVIEW  

NLE Websites -- All DOE Office Websites (Extended Search)

Parking and the ENERGY STAR Score in the United States and Canada Page 1 Parking and the ENERGY STAR Score in the United States and Canada Page 1 Parking and the ENERGY STAR Score in the United States and Canada Technical Reference OVERVIEW The ENERGY STAR score provides a fair assessment of the energy performance of a property relative to its peers, taking into account the climate, weather, and business activities at the property. Parking areas are not eligible to earn the ENERGY STAR score. However, because parking is a common amenity at other commercial building types (i.e., office and hotels), the ENERGY STAR score does make adjustments to accommodate for the presence of parking.

228

Tank characterization reference guide  

Science Conference Proceedings (OSTI)

Characterization of the Hanford Site high-level waste storage tanks supports safety issue resolution; operations and maintenance requirements; and retrieval, pretreatment, vitrification, and disposal technology development. Technical, historical, and programmatic information about the waste tanks is often scattered among many sources, if it is documented at all. This Tank Characterization Reference Guide, therefore, serves as a common location for much of the generic tank information that is otherwise contained in many documents. The report is intended to be an introduction to the issues and history surrounding the generation, storage, and management of the liquid process wastes, and a presentation of the sampling, analysis, and modeling activities that support the current waste characterization. This report should provide a basis upon which those unfamiliar with the Hanford Site tank farms can start their research.

De Lorenzo, D.S.; DiCenso, A.T.; Hiller, D.B.; Johnson, K.W.; Rutherford, J.H.; Smith, D.J. [Los Alamos Technical Associates, Kennewick, WA (United States); Simpson, B.C. [Westinghouse Hanford Co., Richland, WA (United States)

1994-09-01T23:59:59.000Z

229

Nuclear Science References Database  

E-Print Network (OSTI)

The Nuclear Science References (NSR) database together with its associated Web interface, is the world's only comprehensive source of easily accessible low- and intermediate-energy nuclear physics bibliographic information for more than 210,000 articles since the beginning of nuclear science. The weekly-updated NSR database provides essential support for nuclear data evaluation, compilation and research activities. The principles of the database and Web application development and maintenance are described. Examples of nuclear structure, reaction and decay applications are specifically included. The complete NSR database is freely available at the websites of the National Nuclear Data Center http://www.nndc.bnl.gov/nsr and the International Atomic Energy Agency http://www-nds.iaea.org/nsr.

B. Pritychenko; E. B?ták; B. Singh; J. Totans

2013-02-27T23:59:59.000Z

230

Relay contact monitoring system  

Science Conference Proceedings (OSTI)

A switching system for switching on and off heating and air conditioning units in an environmental control system. The switching system includes a thermostat and a relay conductively coupled to the thermostat. The relay has a contact, which is responsive to a change signal for changing its position. The system further includes a programmable monitor having predetermined positions stored in a memory. The monitor is conductively coupled to the contact and to the thermostat for continually determining the position of the contact, and for sending a change signal to the relay for switching the position of the contact, as needed, to be in conformance with a predetermined position stored in the memory. 3 figs.

Mehta, V.

1994-01-11T23:59:59.000Z

231

Radiation monitor reporting requirements  

SciTech Connect

Within High-Level Waste Management (HLWM), CAMs and VAMPs are currently considered Class B equipment, therefore, alarm conditions associated with the CAMs and VAMPs result in an Unusual Occurrence or Off-Normal notification and subsequent occurrence reporting. Recent equipment difficulties associated with Continuous Air Monitors (CAMs) and Victoreen Area Radiation Monitors (VAMPs) have resulted in a significant number of notification reports. These notification have the potential to decrease operator sensitivity to the significance of specific CAM and VAMP failures. Additionally, the reports are extremely costly and are not appropriate as a means for tracking and trending equipment performance. This report provides a technical basis for a change in Waste Management occurrence reporting categorization for specific CAM and VAMP failure modes.

Bates, W.F.

1993-12-10T23:59:59.000Z

232

Energy and American Society : a Reference Handbook  

E-Print Network (OSTI)

American Society: A Reference Handbook By E. Willard MillerSOCIETY: A REFERENCE HANDBOOK (Contemporary World IssuesSOCIETY: A REFERENCE HANDBOOK is an important reference work

Li, Haipeng

1996-01-01T23:59:59.000Z

233

Weld Monitor  

NLE Websites -- All DOE Office Websites (Extended Search)

Monitoring of Laser Beam Welding Monitoring of Laser Beam Welding Using Infrared Weld Emissions P. G. Sanders, J. S. Keske, G. Kornecki, and K. H. Leong Technology Development Division Argonne National Laboratory Argonne, IL 60439 USA The submitted manuscript has been authorized by a contractor of the U. S. Government under contract No. W-31-109-ENG-38. Accordingly, the U. S. Government retains a non-exclusive, royalty-free license to publish or reproduce the published form of this contribution, or allow others to do so, for U. S. Government purposes. Abstract A non-obtrusive, pre-aligned, solid-state device has been developed to monitor the primary infrared emissions during laser welding. The weld monitor output is a 100-1000 mV signal that depends on the beam power and weld characteristics. The DC level of this signal is related to weld

234

Radioactivity Standard Reference Material Program  

Science Conference Proceedings (OSTI)

... Summary: The Standard Reference Materials Program of the National Institute of Standards and Technology (NIST) provides science, industry, and ...

2013-03-27T23:59:59.000Z

235

Molecular diagnostics: harmonization through reference ...  

Science Conference Proceedings (OSTI)

... GeT-RM: Genetic Testing Reference Materials Coordination Program; HSS: Department of Health and Human Services; IRMM: Institute for ...

2012-10-09T23:59:59.000Z

236

NIST Standard Reference Database 23  

Science Conference Proceedings (OSTI)

... 6 Sample MATLAB Code.....53 B ... the IIR and ASHRAE reference states ... in slightly different values than ...

2011-01-03T23:59:59.000Z

237

Chemistry Standard Reference Materials Portal  

Science Conference Proceedings (OSTI)

... Bombings. photo of Gulf of Mexico crude oil SRM NIST Releases Gulf of Mexico Crude Oil Reference Material. canine officer ...

2013-09-19T23:59:59.000Z

238

Reference: Revised Tariff Sheet  

E-Print Network (OSTI)

Company (TrAILCo), a revised tariff sheet to correct the FERC Form No. 1 line reference in TrAILCo’s formula rate. Pursuant to the authority delegated to the Director, Division of Electric Power Regulation- East, under 18 C.F.R. § 375.307, your submittal filed in the above referenced docket is accepted for filing, effective May 17, 2010, as requested. 1 Notice of the filing was published in the Federal Register, with comments, protests, or interventions due on or before June 3, 2010. No protests or adverse comments were filed. American Municipal Power, Inc. and PJM Interconnection, LLC filed timely motions to intervene. Notices of intervention and unopposed timely filed motions to intervene are granted pursuant to Rule 214 of the Commission’s Rules of Practice and Procedure (18 C.F.R. § 385.214). Any opposed or untimely filed motion to intervene is governed by the provisions of Rule 214. This acceptance for filing shall not be construed as constituting approval of any rate, charge, classification or any rule, regulation, or practice affecting such rate or 1

Stephen Angle Esq; Dear Mr. Angle; Jignasa P. Gadani

2010-01-01T23:59:59.000Z

239

Sensor Characteristics Reference Guide  

Science Conference Proceedings (OSTI)

The Buildings Technologies Office (BTO), within the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), is initiating a new program in Sensor and Controls. The vision of this program is: • Buildings operating automatically and continuously at peak energy efficiency over their lifetimes and interoperating effectively with the electric power grid. • Buildings that are self-configuring, self-commissioning, self-learning, self-diagnosing, self-healing, and self-transacting to enable continuous peak performance. • Lower overall building operating costs and higher asset valuation. The overarching goal is to capture 30% energy savings by enhanced management of energy consuming assets and systems through development of cost-effective sensors and controls. One step in achieving this vision is the publication of this Sensor Characteristics Reference Guide. The purpose of the guide is to inform building owners and operators of the current status, capabilities, and limitations of sensor technologies. It is hoped that this guide will aid in the design and procurement process and result in successful implementation of building sensor and control systems. DOE will also use this guide to identify research priorities, develop future specifications for potential market adoption, and provide market clarity through unbiased information

Cree, Johnathan V.; Dansu, A.; Fuhr, P.; Lanzisera, Steven M.; McIntyre, T.; Muehleisen, Ralph T.; Starke, M.; Banerjee, Pranab; Kuruganti, T.; Castello, C.

2013-04-01T23:59:59.000Z

240

LAI References and Summaries  

NLE Websites -- All DOE Office Websites (Extended Search)

Cart Sign In/Register Quick Data Search Help icon Go NASA Meatball Cart Sign In/Register Quick Data Search Help icon Go NASA Meatball No JAVASCRIPT Capabilities. This site will not function without JavaScript. Please use the Web Product Tree. or anonymous FTP at ftp://daac.ornl.gov/data. Global Leaf Area Index Data from Field Measurements, 1932-2000 References and summaries for literature on leaf area index (reviews, methodology, etc.) Barclay, H. J. (1998) Conversion of total leaf area to projcted leaf area in lodgepole pine and Douglas-fir. Tree PHysiology 18, 185-193. Summary It is noted that three distinct definitions of leaf area index (LAI) in the literature have no predictable relationship with each other. Conversion factors were derived, from total LAI to projected LAI of horizontal leaves and to projected LAI for inclined leaves of lodgepole pine and coastal Douglas-fir, enabling comparison of results from different studies. An algorithm was derived to allow determination of these factors based on twig angles and the angles that the foliage subtends with the twig. The conversion factor was more sensitive to differences in vertical angles of the twigs than to twig rotation or foliar arrangement on the twig.

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Benchmark Monitoring: Retired Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Completed Batch Jobs Completed Parallel Jobs Usage Reports Hopper Benchmark Monitoring Edison Benchmark Monitoring Carver Benchmark Monitoring Benchmark Monitoring: Retired Systems...

242

Rooftop Unitary Air Conditioner with Integral Dedicated Outdoor Air System  

SciTech Connect

Energy use of rooftop and other unitary air-conditioners in commercial applications accounts for about 1 quad (10{sup 15} Btu) of primary energy use annually in the U.S. [Reference 7]. The realization that this cooling equipment accounts for the majority of commercial building cooled floorspace and the majority also of commercial building energy use has spurred development of improved-efficiency equipment as well as development of stricter standards addressing efficiency levels. Another key market driver affecting design of rooftop air-conditioning equipment has been concern regarding comfort and the control of humidity. Trends for increases in outdoor air ventilation rates in certain applications, and the increasing concern about indoor air quality problems associated with humidity levels and moisture in buildings points to a need for improved dehumidification capability in air-conditioning equipment of all types. In many cases addressing this issue exacerbates energy efficiency, and vice versa. The integrated dedicated outdoor air system configuration developed in this project addresses both energy and comfort/humidity issues.

Tiax Llc

2006-02-28T23:59:59.000Z

243

AirShares EU Carbon Allowances Fund | Open Energy Information  

Open Energy Info (EERE)

AirShares EU Carbon Allowances Fund AirShares EU Carbon Allowances Fund Jump to: navigation, search Name AirShares EU Carbon Allowances Fund Place New York, New York Zip 10170 Product AirShares is a commodity pool for exchange-traded futures contracts for EUAs. References AirShares EU Carbon Allowances Fund[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. AirShares EU Carbon Allowances Fund is a company located in New York, New York . References ↑ "AirShares EU Carbon Allowances Fund" Retrieved from "http://en.openei.org/w/index.php?title=AirShares_EU_Carbon_Allowances_Fund&oldid=341942" Categories: Clean Energy Organizations Companies Organizations Stubs What links here Related changes

244

Capillary reference half-cell  

DOE Patents (OSTI)

The present invention is a reference half-cell electrode wherein intermingling of test fluid with reference fluid does not affect the performance of the reference half-cell over a long time. This intermingling reference half-cell may be used as a single or double junction submersible or surface reference electrode. The intermingling reference half-cell relies on a capillary tube having a first end open to reference fluid and a second end open to test fluid wherein the small diameter of the capillary tube limits free motion of fluid within the capillary to diffusion. The electrode is placed near the first end of the capillary in contact with the reference fluid. The method of operation of the present invention begins with filling the capillary tube with a reference solution. After closing the first end of the capillary, the capillary tube may be fully submerged or partially submerged with the second open end inserted into test fluid. Since the electrode is placed near the first end of the capillary, and since the test fluid may intermingle with the reference fluid through the second open end only by diffusion, this intermingling capillary reference half-cell provides a stable voltage potential for long time periods. 11 figs.

Hall, S.H.

1996-02-13T23:59:59.000Z

245

reference | OpenEI Community  

Open Energy Info (EERE)

98 98 Varnish cache server Home Groups Community Central Green Button Applications Developer Utility Rate FRED: FRee Energy Database More Public Groups Private Groups Features Groups Blog posts Content Stream Documents Discussions Polls Q & A Events Notices My stuff Energy blogs 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142235098 Varnish cache server reference Home Jweers's picture Submitted by Jweers(83) Contributor 7 August, 2013 - 18:23 New Robust References! citation citing developer formatting reference Semantic Mediawiki wiki Check out the new Reference Form. Adding a reference object to OpenEI using this form is the most complete way to cite a reference. After providing the name of your reference, the form will ask for your document

246

Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project  

SciTech Connect

Groundwater is monitored at the Hanford Site to fulfill a variety of state and federal regulations, including the Atomic Energy Act of 1954; the Resource Conservation and Recovery Act of 1976; the Comprehensive Environmental Response, Compensation, and Liability Act of 1980; and Washington Administrative Code. Separate monitoring plans are prepared for various requirements, but sampling is coordinated and data are shared among users to avoid duplication of effort. The U.S. Department of Energy manages these activities through the Hanford Groundwater Monitoring Project. This document is an integrated monitoring plan for the groundwater project. It documents well and constituent lists for monitoring required by the Atomic Energy Act of 1954 and its implementing orders; includes other, established monitoring plans by reference; and appends a master well/constituent/ frequency matrix for the entire site. The objectives of monitoring fall into three general categories: plume and trend tracking, treatment/ storage/disposal unit monitoring, and remediation performance monitoring. Criteria for selecting Atomic Energy Act of 1954 monitoring networks include locations of wells in relation to known plumes or contaminant sources, well depth and construction, historical data, proximity to the Columbia River, water supplies, or other areas of special interest, and well use for other programs. Constituent lists were chosen based on known plumes and waste histories, historical groundwater data, and, in some cases, statistical modeling. Sampling frequencies were based on regulatory requirements, variability of historical data, and proximity to key areas. For sitewide plumes, most wells are sampled every 3 years. Wells monitoring specific waste sites or in areas of high variability will be sampled more frequently.

MJ Hartman; PE Dresel; JW Lindberg; DR Newcomer; EC Thornton

2000-10-18T23:59:59.000Z

247

Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project  

SciTech Connect

Groundwater is monitored at the Hanford Site to fulfill a variety of state and federal regulations, including the Atomic Energy Act of 1954 the Resource Conservation and Recovery Act of 1976 the Comprehensive Environmental Response, Compensation, and Liability Act of 1980; and Washington Administrative Code. Separate monitoring plans are prepared for various requirements, but sampling is coordinated and data are shared among users to avoid duplication of effort. The US Department of Energy manages these activities through the Hanford Groundwater Monitoring Project. This document is an integrated monitoring plan for the groundwater project. It documents well and constituent lists for monitoring required by the Atomic Energy Act of 1954 and its implementing orders; includes other, established monitoring plans by reference; and appends a master well/constituent/frequency matrix for the entire site. The objectives of monitoring fall into three general categories plume and trend tracking, treatment/storage/disposal unit monitoring, and remediation performance monitoring. Criteria for selecting Atomic Energy Act of 1954 monitoring networks include locations of wells in relation to known plumes or contaminant sources, well depth and construction, historical data, proximity to the Columbia River, water supplies, or other areas of special interest, and well use for other programs. Constituent lists were chosen based on known plumes and waste histories, historical groundwater data, and, in some cases, statistical modeling. Sampling frequencies were based on regulatory requirements, variability of historical data, and proximity to key areas. For sitewide plumes, most wells are sampled every 3 years. Wells monitoring specific waste sites or in areas of high variability will be sampled more frequently.

Newcomer, D.R.; Thornton, E.C.; Hartman, M.J.; Dresel, P.E.

1999-10-06T23:59:59.000Z

248

Underbalanced drilling with air offers many pluses  

Science Conference Proceedings (OSTI)

A pressure overbalance during conventional drilling can cause significant fluid filtrate invasion and lost circulation. Fluid invasion into the formation can lead to formation damage, high mud costs, a need for expensive completions, and well productivity impairment. Because underbalanced drilling creates a natural tendency for fluid and gas to flow from the formation to the borehole, successful underbalanced drilling depends upon the appropriate selection of circulating fluid. The use of a compressible fluid in the circulating system, referred to as air drilling, lowers the downhole pressure, allowing drilling into and beyond these sensitive formations. The paper discusses the equipment needed; well control; downhole air requirements; air drilling techniques using dry air, air-mist, stable foam, stiff foam, and aerated-fluid; downhole fires; directional air drilling; and well completions.

Shale, L. [Baker Hughes Inteq, Houston, TX (United States)

1995-06-26T23:59:59.000Z

249

PDSF Monitoring  

NLE Websites -- All DOE Office Websites (Extended Search)

PDSF Monitoring PDSF Monitoring The plot below is a measure of the read and write rates a single user would experience via the PDSF batch system. Jobs are submitted sequentially every hour to the debug queue. If a jobs doesn't finish in 8 minutes, it is killed and a -1 rate is written out. The read rates are calculated by copying a directory containing 2 files totaling 274 MB from the eliza directories to the $TMPDIR on the node running the job. The write rates are calculated by untarring a tarball on the eliza directories. The write rates are typically around a factor of two slower than the read rates, because the data still has to travel to the compute node and then back to the eliza for writing. The I/O rates are taken from the ganglia monitoring and serve as a measure of the amount of

250

Air Pollution Control Program (South Dakota) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Pollution Control Program (South Dakota) Air Pollution Control Program (South Dakota) Air Pollution Control Program (South Dakota) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State South Dakota Program Type Siting and Permitting Provider South Dakota Department of Environment and Natural Resources South Dakota's Air Pollution Control Program is intended to maintain air quality standards through monitoring the ambient air quality throughout the

251

Air Showers and Geomagnetic Field  

E-Print Network (OSTI)

The influence of the geomagnetic field on the development of air showers is studied. The well known International Geomagnetic Reference Field was included in the AIRES air shower simulation program as an auxiliary tool to allow calculating very accurate estimations of the geomagnetic field given the geographic coordinates, altitude above sea level and date of a given event. Our simulations indicate that the geomagnetic deflections alter significantly some shower observables like, for example, the lateral distribution of muons in the case of events with large zenith angles (larger than 75 degrees). On the other hand, such alterations seem not to be important for smaller zenith angles. Global observables like total numbers of particles or longitudinal development parameters do not present appreciable dependences on the geomagnetic deflections for all the cases that were studied.

A. Cillis; S. J. Sciutto

1999-07-31T23:59:59.000Z

252

Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis  

SciTech Connect

This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants.

MULKEY, C.H.

1999-07-06T23:59:59.000Z

253

REFERENCE: INSPECTORS: DATE OF REPORT:  

E-Print Network (OSTI)

SITE: Installations for monitoring and controlling radioactive discharges and for surveillance of the environment in Lithuania during normal operations of the Ignalina nuclear power plant

Ignalina Nuclear; Power Plant; Mr S. Van Der Stricht; Mr V. Tanner; Mr P. Beuseling; Mr Y-h; Bouget France; Ms A. Godeanu Metz (trainee; Y-h Bouget; A. Godeanu Metz; P. Beuseling

2005-01-01T23:59:59.000Z

254

Investigating the association between birth weight and complementary air pollution metrics: a cohort study  

E-Print Network (OSTI)

land use regression models for traffic-related air pollution.air pollution metrics, for pregnancy-long exposures (a) Landpollution were used (measurements from ambient monitoring stations, predictions from land

Laurent, Olivier; Wu, Jun; Li, Lianfa; Chung, Judith; Bartell, Scott

2013-01-01T23:59:59.000Z

255

Numerical Simulations of the Meteorological and Dispersion Conditions during an Air Pollution Episode over Athens, Greece  

Science Conference Proceedings (OSTI)

In this study a summer air pollution episode from 6 to 8 August 1994 over Athens, Greece, is investigated through advanced atmospheric modeling. This episode was reported from the air quality monitoring network, as well as from research aircraft ...

V. Kotroni; G. Kallos; K. Lagouvardos; M. Varinou; R. Walko

1999-04-01T23:59:59.000Z

256

Monitor 1979  

SciTech Connect

The status, improvements, and accomplishments of the Monitor remote-handling system previously reported are updated. It also outlines the goals for the future to improve the efficiency and speed of remote-maintenance operations at the Clinton P. Anderson Meson Physics Facility (LAMPF).

Grisham, D.L.; Ekberg, E.L.; Lambert, J.E.; Meyer, R.E.; Stroik, P.J.; Wickham, M.D.

1979-01-01T23:59:59.000Z

257

Monitoring well  

DOE Patents (OSTI)

A monitoring well is described which includes: a conduit defining a passageway, the conduit having a proximal and opposite, distal end; a coupler connected in fluid flowing relationship with the passageway; and a porous housing borne by the coupler and connected in fluid flowing relation thereto. 8 figs.

Hubbell, J.M.; Sisson, J.B.

1999-06-29T23:59:59.000Z

258

Monitoring well  

DOE Patents (OSTI)

A monitoring well including a conduit defining a passageway, the conduit having a proximal and opposite, distal end; a coupler connected in fluid flowing relationship with the passageway; and a porous housing borne by the coupler and connected in fluid flowing relation thereto.

Hubbell, Joel M. (Idaho Falls, ID); Sisson, James B. (Idaho Falls, ID)

1999-01-01T23:59:59.000Z

259

Tips: References | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

References References Tips: References April 11, 2012 - 9:03am Addthis Tips: References The following resources were used to develop the Energy Savers Guide: Tips on Saving Money and Energy at Home: Alternative Fuels and Advanced Vehicles Data Center American Council for an Energy-Efficient Economy Cool Roof Rating Council Database of State Incentives for Renewables & Efficiency (DSIRE) DOE Building America DOE Building Technologies Program DOE Building Technologies Program, 2010 Buildings Energy Databook DOE Energy Information Administration Residential Energy Consumption Survey DOE/EPA Fuel Economy Guide DOE Federal Energy Management Program DOE Office of Electricity Delivery and Energy Reliability ENERGY STAR® Green Roofs for Healthy Cities National Renewable Energy Laboratory

260

References | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog References Home > About Us > Our Programs > Nuclear Security > Nuclear Materials Management &...

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

FAQS Reference Guide – Facility Representative  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the October 2010 edition of DOE-STD-1151-2010, Facility Representative Functional Area Qualification Standard.

262

FAQS Reference Guide – Criticality Safety  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the April 2009 edition of DOE-STD-1173-2009, Criticality Safety Functional Area Qualification Standard.

263

OpenEI - Technical Reference  

Open Energy Info (EERE)

http:en.openei.orgdatasetstaxonomyterm8710 en Technical Reference and Technical Database for Hydrogen Compatibility of Materials http:en.openei.orgdatasetsnode927...

264

FAQS Reference Guide- Chemical Processing  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the February 2010 edition of DOE-STD-1176-2010, Chemical Processing Functional Area Qualification Standard.

265

Chemistry Standard Reference Data Portal  

Science Conference Proceedings (OSTI)

... photo of Gulf of Mexico crude oil SRM NIST Releases Gulf of Mexico Crude Oil Reference Material. 11MML036_nanotubes_srm_CS ...

2013-09-19T23:59:59.000Z

266

FAQS Reference Guide – Waste Management  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the January 2003 edition of DOE-STD-1159-2003, Waste Management Functional Area Qualification Standard.

267

FAQS Reference Guide – Environmental Restoration  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the November 2002 edition of DOE-STD-1157-2002, Environmental Restoration Functional Area Qualification Standard.

268

FAQS Reference Guide – Environmental Compliance  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide addresses the competency statements in the June 2011 edition of DOE-STD-1156-2011, Environmental Compliance Functional Area Qualification Standard.

269

Linear air-fuel sensor development  

DOE Green Energy (OSTI)

The electrochemical zirconia solid electrolyte oxygen sensor, is extensively used for monitoring oxygen concentrations in various fields. They are currently utilized in automobiles to monitor the exhaust gas composition and control the air-to-fuel ratio, thus reducing harmful emission components and improving fuel economy. Zirconia oxygen sensors, are divided into two classes of devices: (1) potentiometric or logarithmic air/fuel sensors; and (2) amperometric or linear air/fuel sensors. The potentiometric sensors are ideally suited to monitor the air-to-fuel ratio close to the complete combustion stoichiometry; a value of about 14.8 to 1 parts by volume. This occurs because the oxygen concentration changes by many orders of magnitude as the air/fuel ratio is varied through the stoichiometric value. However, the potentiometric sensor is not very sensitive to changes in oxygen partial pressure away from the stoichiometric point due to the logarithmic dependence of the output voltage signal on the oxygen partial pressure. It is often advantageous to operate gasoline power piston engines with excess combustion air; this improves fuel economy and reduces hydrocarbon emissions. To maintain stable combustion away from stoichiometry, and enable engines to operate in the excess oxygen (lean burn) region several limiting-current amperometric sensors have been reported. These sensors are based on the electrochemical oxygen ion pumping of a zirconia electrolyte. They typically show reproducible limiting current plateaus with an applied voltage caused by the gas diffusion overpotential at the cathode.

Garzon, F. [Los Alamos National Lab., NM (United States); Miller, C. [General Motors, Flint, MI (United States). GM/Delphi E. Division

1996-12-14T23:59:59.000Z

270

Definition: Line Transformer Monitors | Open Energy Information  

Open Energy Info (EERE)

Transformer Monitors Transformer Monitors Jump to: navigation, search Dictionary.png Line Transformer Monitors Transformer Monitoring System can monitor different aspects of transformers, including oil levels and multiple temperatures within the transformer. This allows for analysis of the health of either individual key power transformers or multiple power transformers networked in the system. For example, the transformer monitors provide transformer oil dissolved gas analysis (DGA), oil temperature, ambient temperature, and moisture in oil measurements. These measurements are made in relation to transformer load.[1] Related Terms transformer, system, transformer References ↑ https://www.smartgrid.gov/category/technology/line_transformer_monitors [[Cat LikeLike UnlikeLike You like this.Sign Up to see what your friends like.

271

Air Leakage of Furnaces and Air Handlers  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Leakage of Furnaces and Air Handlers Air Leakage of Furnaces and Air Handlers Title Air Leakage of Furnaces and Air Handlers Publication Type Journal Article LBNL Report Number LBNL-5553E Year of Publication 2010 Authors Walker, Iain S., Mile Lubliner, Darryl J. Dickerhoff, and William W. Delp Journal 2010 ACEEE Summer Study on Energy Efficiency in Buildings The Climate for efficiency is now Date Published 08/2010 Abstract In recent years, great strides have been made in reducing air leakage in residential and to a lesser extent small commercial forced air duct systems. Several authorities have introduced low leakage limits for thermal distribution systems; for example, the State of California Energy Code for Buildings gives credit for systems that leak less than 6% of the total air flow at 25 Pa.

272

US South Coast Air Quality Management District SCAQMD | Open Energy  

Open Energy Info (EERE)

South Coast Air Quality Management District SCAQMD South Coast Air Quality Management District SCAQMD Jump to: navigation, search Name US South Coast Air Quality Management District (SCAQMD) Place Diamond Bar, California Zip CA 91765 Product String representation "The SCAQMD's Te ... nate emissions." is too long. References US South Coast Air Quality Management District (SCAQMD)[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. US South Coast Air Quality Management District (SCAQMD) is a company located in Diamond Bar, California . References ↑ "US South Coast Air Quality Management District (SCAQMD)" Retrieved from "http://en.openei.org/w/index.php?title=US_South_Coast_Air_Quality_Management_District_SCAQMD&oldid=352623

273

1984 environmental monitoring report  

Science Conference Proceedings (OSTI)

The environmental monitoring program has been designed to ensure that BNL facilities operate such that the applicable environmental standards and effluent control requirements have been met. A listing, as required by DOE Order 5484.1 of BNL facilities, of environmental agencies and permits is provided in the Environmental Program Information Section 3.0, Table B. Since the aquifer underlying Long Island has been designated a ''sole source'' aquifer, the Environmental Protection Agency (EPA) Drinking Water Standards have been used in the assessment of ground water data. However, the limits prescribed in the regulations are not directly applicable to the monitoring well data since (1) the standards apply to a community water supply system, i.e., one serving more than 25 individuals, and (2) the standards represent an annual average concentration. Since the monitoring wells are not components of the Laboratory's water supply system, the EPA drinking water standards are employed as reference criteria to which the surveillance well data is compared. The standards also serve as guidance levels for any appropriate remedial action. 36 refs., 9 figs., 40 tabs.

Day, L.E.; Miltenberger, R.P.; Naidu, J.R. (eds.)

1985-04-01T23:59:59.000Z

274

reference case | OpenEI  

Open Energy Info (EERE)

reference case reference case Dataset Summary Description This dataset comes from the Energy Information Administration (EIA), and is part of the 2011 Annual Energy Outlook Report (AEO2011). This dataset is table 1, and contains only the reference case. The dataset uses quadrillion BTUs, and quantifies the energy prices using U.S. dollars. The data is broken down into total production, imports, exports, consumption, and prices for energy types. Source EIA Date Released April 26th, 2011 (3 years ago) Date Updated Unknown Keywords 2011 AEO consumption EIA export import production reference case total energy Data application/vnd.ms-excel icon AEO2011: Total Energy Supply, Disposition, and Price Summary - Reference Case (xls, 112.8 KiB) Quality Metrics Level of Review Peer Reviewed

275

Tritium monitor  

DOE Patents (OSTI)

A system for continuously monitoring the concentration of tritium in an aqueous stream. The system pumps a sample of the stream to magnesium-filled combustion tube which reduces the sample to extract hydrogen gas. The hydrogen gas is then sent to an isotope separation device where it is separated into two groups of isotopes: a first group of isotopes containing concentrations of deuterium and tritium, and a second group of isotopes having substantially no deuterium and tritium. The first group of isotopes containing concentrations of deuterium and tritium is then passed through a tritium detector that produces an output proportional to the concentration of tritium detected. Preferably, the detection system also includes the necessary automation and data collection equipment and instrumentation for continuously monitoring an aqueous stream.

Chastagner, Philippe (Augusta, GA)

1994-01-01T23:59:59.000Z

276

Tritium monitor  

DOE Patents (OSTI)

A system is described for continuously monitoring the concentration of tritium in an aqueous stream. The system pumps a sample of the stream to magnesium-filled combustion tube which reduces the sample to extract hydrogen gas. The hydrogen gas is then sent to an isotope separation device where it is separated into two groups of isotopes: a first group of isotopes containing concentrations of deuterium and tritium, and a second group of isotopes having substantially no deuterium and tritium. The first group of isotopes containing concentrations of deuterium and tritium is then passed through a tritium detector that produces an output proportional to the concentration of tritium detected. Preferably, the detection system also includes the necessary automation and data collection equipment and instrumentation for continuously monitoring an aqueous stream. 1 fig.

Chastagner, P.

1994-06-14T23:59:59.000Z

277

Tritium monitor  

DOE Patents (OSTI)

This invention is comprised of a system for continuously monitoring the concentration of tritium in an aqueous stream. The system pumps a sample of the stream to magnesium-filled combustion tube which reduces the sample to extract hydrogen gas. The hydrogen gas is then sent to an isotope separation device where it is separated into two groups of isotopes: a first group of isotopes containing concentrations of deuterium and tritium, and a second group of isotopes having substantially no deuterium and tritium. The first group of isotopes containing concentrations of deuterium and tritium is then passed through a tritium detector that produces an output proportional to the concentration of tritium detected. Preferably, the detection system also includes the necessary automation and data collection equipment and instrumentation for continuously monitoring an aqueous stream.

Chastagner, P.

1992-12-31T23:59:59.000Z

278

Compressed Air Energy Storage Demonstration Newsletter  

Science Conference Proceedings (OSTI)

The Compressed Air Energy Storage (CAES) Demonstration Project includes the phased planning, engineering design, construction, demonstration, and performance monitoring of two CAES plants. One plant will be a system rated at 300 MWs for up to 10 hours with a below-ground reservoir for bulk energy air storage, and the other will be a system rated at 15 MWs for 2 hours with above-ground air vessel/piping. This is a critical technology demonstration project that is necessary to enable higher penetration of ...

2011-04-21T23:59:59.000Z

279

5 CCR 1001-5 Colorado Stationary Source Permitting and Air Pollution...  

Open Energy Info (EERE)

5 Colorado Stationary Source Permitting and Air Pollution Control Emission Notice Requirements Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Reference Material: 5...

280

Metal-Air Batteries  

Science Conference Proceedings (OSTI)

Metal-air batteries have much higher specific energies than most currently available primary and rechargeable batteries. Recent advances in electrode materials and electrolytes, as well as new designs on metal-air batteries, have attracted intensive effort in recent years, especially in the development of lithium-air batteries. The general principle in metal-air batteries will be reviewed in this chapter. The materials, preparation methods, and performances of metal-air batteries will be discussed. Two main metal-air batteries, Zn-air and Li-air batteries will be discussed in detail. Other type of metal-air batteries will also be described.

Zhang, Jiguang; Bruce, Peter G.; Zhang, Gregory

2011-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

FAQS Reference Guide - Transportation and Traffic Management...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

FAQS Reference Guide - Transportation and Traffic Management FAQS Reference Guide - Transportation and Traffic Management This reference guide addresses the competency statements...

282

NETL: Coal & Power Systems Reference Shelf  

NLE Websites -- All DOE Office Websites (Extended Search)

Reference Shelf Coal & Power Systems Reference Shelf Below are links to recent Strategic Center for Coal (SCC) related documents and reference materials. Each technology area...

283

A Reference Software Architecture to Support Unmanned Aircraft Integration in the National Airspace System  

Science Conference Proceedings (OSTI)

This paper outlines an architecture that provides data and software services to enable a set of Unmanned Aircraft (UA) platforms to operate in a wide range of air domains which may include terminal, en route, oceanic and tactical. The architecture allows ... Keywords: Reference architecture, Sense and Avoid, Service Oriented Architecture, Testbed, Unmanned Air vehicle

Curtis W. Heisey; Adam G. Hendrickson; Barbara J. Chludzinski; Rodney E. Cole; Mark Ford; Larry Herbek; Magnus Ljungberg; Zakir Magdum; D. Marquis; Alexander Mezhirov; John L. Pennell; Ted A. Roe; Andrew J. Weinert

2013-01-01T23:59:59.000Z

284

Geomagnetic Field and Air Shower Simulations  

E-Print Network (OSTI)

The influence of the geomagnetic field on the development of air showers is studied. The well known International Geomagnetic Reference Field was included in the AIRES air shower simulation program as an auxiliary tool to allow calculating very accurate estimations of the geomagnetic field given the geographic coordinates, altitude above sea level and date of a given event. Some test simulations made for representative cases indicate that some quantities like the lateral distribution of muons experiment significant modifications when the geomagnetic field is taken into account.

A. Cillis; S. J. Sciutto

1997-12-30T23:59:59.000Z

285

AIRS Subpixel Cloud Characterization Using MODIS Cloud Products  

Science Conference Proceedings (OSTI)

The Moderate Resolution Imaging Spectroradiometer (MODIS) and the Atmospheric Infrared Sounder (AIRS) measurements from the Earth Observing System's (EOS's) Aqua satellite enable improved global monitoring of the distribution of clouds. MODIS is ...

Jun Li; W. Paul Menzel; Fengying Sun; Timothy J. Schmit; James Gurka

2004-08-01T23:59:59.000Z

286

Retrieval of Cloud Microphysical Properties from MODIS and AIRS  

Science Conference Proceedings (OSTI)

The Moderate Resolution Imaging Spectroradiometer (MODIS) and the Atmospheric Infrared Sounder (AIRS) measurements from the NASA Earth Observing System Aqua satellite enable global monitoring of the distribution of clouds during day and night. ...

Jun Li; Hung-Lung Huang; Chian-Yi Liu; Ping Yang; Timothy J. Schmit; Heli Wei; Elisabeth Weisz; Li Guan; W. Paul Menzel

2005-10-01T23:59:59.000Z

287

Stack Monitor Operating Experience Review  

Science Conference Proceedings (OSTI)

Stack monitors are used to sense radioactive particulates and gases in effluent air being vented from rooms of nuclear facilities. These monitors record the levels and types of effluents to the environment. This paper presents the results of a stack monitor operating experience review of the U.S. Department of Energy (DOE) Occurrence Reporting and Processing System (ORPS) database records from the past 18 years. Regulations regarding these monitors are briefly described. Operating experiences reported by the U.S. DOE and in engineering literature sources were reviewed to determine the strengths and weaknesses of these monitors. Electrical faults, radiation instrumentation faults, and human errors are the three leading causes of failures. A representative “all modes” failure rate is 1E-04/hr. Repair time estimates vary from an average repair time of 17.5 hours (with spare parts on hand) to 160 hours (without spare parts on hand). These data should support the use of stack monitors in any nuclear facility, including the National Ignition Facility and the international ITER project.

L. C. Cadwallader; S. A. Bruyere

2009-05-01T23:59:59.000Z

288

Benzene Monitor System report  

Science Conference Proceedings (OSTI)

Two systems for monitoring benzene in aqueous streams have been designed and assembled by the Savannah River Technology Center, Analytical Development Section (ADS). These systems were used at TNX to support sampling studies of the full-scale {open_quotes}SRAT/SME/PR{close_quotes} and to provide real-time measurements of benzene in Precipitate Hydrolysis Aqueous (PHA) simulant. This report describes the two ADS Benzene Monitor System (BMS) configurations, provides data on system operation, and reviews the results of scoping tests conducted at TNX. These scoping tests will allow comparison with other benzene measurement options being considered for use in the Defense Waste Processing Facility (DWPF) laboratory. A report detailing the preferred BMS configuration statistical performance during recent tests has been issued under separate title: Statistical Analyses of the At-line Benzene Monitor Study, SCS-ASG-92-066. The current BMS design, called the At-line Benzene Monitor (ALBM), allows remote measurement of benzene in PHA solutions. The authors have demonstrated the ability to calibrate and operate this system using peanut vials from a standard Hydragard{trademark} sampler. The equipment and materials used to construct the ALBM are similar to those already used in other applications by the DWPF lab. The precision of this system ({+-}0.5% Relative Standard Deviation (RSD) at 1 sigma) is better than the purge & trap-gas chromatograpy reference method currently in use. Both BMSs provide a direct measurement of the benzene that can be purged from a solution with no sample pretreatment. Each analysis requires about five minutes per sample, and the system operation requires no special skills or training. The analyzer`s computer software can be tailored to provide desired outputs. Use of this system produces no waste stream other than the samples themselves (i.e. no organic extractants).

Livingston, R.R.

1992-10-12T23:59:59.000Z

289

Continuous emission monitor for incinerators  

Science Conference Proceedings (OSTI)

This paper describes the development of Fourier transform infrared (FTIR) spectroscopy to continuous monitoring of incinerator emissions. Fourier transform infrared spectroscopy is well suited to this application because it can identify and quantify selected target analytes in a complex mixture without first separating the components in the mixture. Currently, there is no on-stream method to determine the destruction of hazardous substances, such as benzene, or to continuously monitor for hazardous products of incomplete combustion (PICs) in incinerator exhaust emissions. This capability is especially important because of Federal regulations in the Clean Air Act of 1990, which requires the monitoring of air toxics (Title III), the Resource Conservation and Recovery Act (RCRA), and the Toxic Substances Control Act (TSCA). An on-stream continuous emission monitor (CEM) that can differentiate species in the ppm and ppb range and can calculate the destruction and removal efficiency (DRE) could be used to determine the safety and reliability of incinerators. This information can be used to address reasonable public concern about incinerator safety and aid in the permitting process.

Demirgian, J.

1992-01-01T23:59:59.000Z

290

Continuous emission monitor for incinerators  

Science Conference Proceedings (OSTI)

This paper describes the development of Fourier transform infrared (FTIR) spectroscopy to continuous monitoring of incinerator emissions. Fourier transform infrared spectroscopy is well suited to this application because it can identify and quantify selected target analytes in a complex mixture without first separating the components in the mixture. Currently, there is no on-stream method to determine the destruction of hazardous substances, such as benzene, or to continuously monitor for hazardous products of incomplete combustion (PICs) in incinerator exhaust emissions. This capability is especially important because of Federal regulations in the Clean Air Act of 1990, which requires the monitoring of air toxics (Title III), the Resource Conservation and Recovery Act (RCRA), and the Toxic Substances Control Act (TSCA). An on-stream continuous emission monitor (CEM) that can differentiate species in the ppm and ppb range and can calculate the destruction and removal efficiency (DRE) could be used to determine the safety and reliability of incinerators. This information can be used to address reasonable public concern about incinerator safety and aid in the permitting process.

Demirgian, J.

1992-07-01T23:59:59.000Z

291

SRNL - Natural Attenuation Monitor  

NLE Websites -- All DOE Office Websites (Extended Search)

Natural Attenuation Monitor covers Natural Attenuation Monitor Published by the US DOE Monitored Natural Attenuation and Enhanced Attenuation for Chlorinated Solvents Technology...

292

Comparison of Pyranometers vs. PV Reference Cells for Evaluation of PV Array Performance  

DOE Green Energy (OSTI)

As the photovoltaics (PV) industry has grown, the need for accurately monitoring the solar resource of PV power plants has increased. Historically, the PV industry has relied on thermopile pyranometers for irradiance measurements, and a large body of historical irradiance data taken with pyranometers exists. However, interest in PV reference devices is increasing. In this paper, we discuss why PV reference devices are better suited for PV applications, and estimate the typical uncertainties in irradiance measurements made with both pyranometers and PV reference devices. We assert that the quantity of interest in monitoring a PV power plant is the equivalent irradiance under the IEC 60904-3 reference solar spectrum that would produce the same electrical response in the PV array as the incident solar radiation. For PV-plant monitoring applications, we find the uncertainties in irradiance measurements of this type to be on the order of +/-5% for thermopile pyranometers and +/-2.4% for PV reference devices.

Dunn, L.; Gostein, M.; Emery, K.

2012-09-01T23:59:59.000Z

293

1982 environmental monitoring report  

SciTech Connect

The environmental levels of radioactivity and other pollutants found in the vicinity of BNL during 1982 are summarized in this report. As an aid in the interpretation of the data, the amounts of radioactivity and other pollutants released in airborne and liquid effluents from Laboratory facilities to the environment are also indicated. The environmental data include external radiation levels; radioactive air particulates; tritium concentrations; the amounts and concentrations of radioactivity in and the water quality of the stream into which liquid effluents are released; the concentrations of radioactivity in biota from the stream; the concentrations of radioactivity in and the water quality of ground waters underlying the Laboratory; and concentrations of radioactivity in milk samples obtained in the vicinity of the Laboratory. 30 references, 9 figures, 18 tables.

Day, L.E.; Naidu, J.R. (eds.)

1983-04-01T23:59:59.000Z

294

1981 environmental monitoring report  

SciTech Connect

The environmental levels of radioactivity and other pollutants found in the vicinity of BNL during 1981 are summarized in this report. As an aid in the interpretation of the data, the amounts of radioactivity and other pollutants released in airborne and liquid effluents from Laboratory facilities to the environment are also indicated. The environmental data includes external radiation levels; radioactive air particulates; tritium and iodine concentrations; the amounts and concentrations of radioactivity in and the water quality of the stream into which liquid effluents are released; the concentrations of radioactivity in sediments and biota from the stream; the concentrations of radioactivity in and the water quality of ground waters underlying the Laboratory; and concentrations of radioactivity in milk samples obtained in the vicinity of the Laboratory. 28 references, 9 figures, 20 tables.

Naidu, J.R.; Olmer, L.L. (eds.)

1982-04-01T23:59:59.000Z

295

Mixed waste characterization reference document  

SciTech Connect

Waste characterization and monitoring are major activities in the management of waste from generation through storage and treatment to disposal. Adequate waste characterization is necessary to ensure safe storage, selection of appropriate and effective treatment, and adherence to disposal standards. For some wastes characterization objectives can be difficult and costly to achieve. The purpose of this document is to evaluate costs of characterizing one such waste type, mixed (hazardous and radioactive) waste. For the purpose of this document, waste characterization includes treatment system monitoring, where monitoring is a supplement or substitute for waste characterization. This document establishes a cost baseline for mixed waste characterization and treatment system monitoring requirements from which to evaluate alternatives. The cost baseline established as part of this work includes costs for a thermal treatment technology (i.e., a rotary kiln incinerator), a nonthermal treatment process (i.e., waste sorting, macronencapsulation, and catalytic wet oxidation), and no treatment (i.e., disposal of waste at the Waste Isolation Pilot Plant (WIPP)). The analysis of improvement over the baseline includes assessment of promising areas for technology development in front-end waste characterization, process equipment, off gas controls, and monitoring. Based on this assessment, an ideal characterization and monitoring configuration is described that minimizes costs and optimizes resources required for waste characterization.

1997-09-01T23:59:59.000Z

296

Technical Reference | OpenEI  

Open Energy Info (EERE)

Reference Reference Dataset Summary Description Technical Reference for Hydrogen Compatibility of Materials Source Sandia National Laboratories Date Released June 03rd, 2010 (4 years ago) Date Updated September 27th, 2012 (2 years ago) Keywords Compatibility of Materials hydrogen NREL Sandia Technical Database Technical Reference Data application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon 1100_cia85_ten_fra_fat.xlsx (xlsx, 60.9 KiB) application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon 1100_san10_fra_fat.xlsx (xlsx, 58.5 KiB) application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon 1100_san10b_fra_fat.xlsx (xlsx, 59.4 KiB) application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon 1100_san11_fra_fat.xlsx (xlsx, 48.4 KiB)

297

Tips: References | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips: References Tips: References Tips: References April 11, 2012 - 9:03am Addthis Tips: References The following resources were used to develop the Energy Savers Guide: Tips on Saving Money and Energy at Home: Alternative Fuels and Advanced Vehicles Data Center American Council for an Energy-Efficient Economy Cool Roof Rating Council Database of State Incentives for Renewables & Efficiency (DSIRE) DOE Building America DOE Building Technologies Program DOE Building Technologies Program, 2010 Buildings Energy Databook DOE Energy Information Administration Residential Energy Consumption Survey DOE/EPA Fuel Economy Guide DOE Federal Energy Management Program DOE Office of Electricity Delivery and Energy Reliability ENERGY STAR® Green Roofs for Healthy Cities National Renewable Energy Laboratory

298

Learning to resolve bridging references  

Science Conference Proceedings (OSTI)

We use machine learning techniques to find the best combination of local focus and lexical distance features for identifying the anchor of mereological bridging references. We find that using first mention, utterance distance, and lexical distance computed ...

Massimo Poesio; Rahul Mehta; Axel Maroudas; Janet Hitzeman

2004-07-01T23:59:59.000Z

299

FAQS Reference Guide –Radiation Protection  

Energy.gov (U.S. Department of Energy (DOE))

This reference guide has been developed to address the competency statements in the December 2003 edition of DOE-STD-1174-2003, Radiation Protection Functional Area Qualification Standard.

300

References  

E-Print Network (OSTI)

In analyzing the ACS photometry of the primary WD stars, Bohlin & Gilliland (2004) found a 2.5 % contribution to the predicted integrated HRC count rates due to the F660N filter transmission rise at the shortest wavelength of the tabulation. Following discussions with G. Hartig, the tabulated value of 0.00604 at 2500 Å was deemed a spurious artifact of the measurement procedure (Leviton et al. 1998a, Leviton et al. 1998b). The ACS filters generally use colored glass substrates to block short wavelengths and are not subject to the kind of UV leak that is indicated by the original data supplied by the IDT. The signal transmitted by the filter at 2500 Å in the lab measurement process was probably dominated by stray light from longer wavelengths. Even though for normal stellar continua, similar errors for other filters are less than 0.5 % of the predicted count rate, all UV transmittance curves with a similar suspicious rise in the UV are corrected to values typical of the nearest measured values. Table 1 lists all of the changes that are implemented in Synphot as a result of this investigation. These changes are also reflected in the ETC

F. R. Boffi; R. C. Bohlin

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

References  

Science Conference Proceedings (OSTI)

... LIBES96. Don Libes, Writing CGI Scripts in Tcl, Proceedings of Tcl/Tk Workshop 96, Monterey, CA, July 10-13, 1996. LUB95. ...

302

References  

Science Conference Proceedings (OSTI)

... LIBES. Don Libes, Writing CGI Scripts in Tcl, Proceedings of Tcl/Tk Workshop 96, Monterey, CA, July 10-13, 1996. URL: http://www.nist.gov/msid. ...

303

References  

Science Conference Proceedings (OSTI)

..., ASM International, 2009, p 625â??658ASM Handbook, Vol 22A, Fundamentals of Modeling for Metals ProcessingHeat-Transfer Equations,...

304

References  

E-Print Network (OSTI)

Nowadays, lots of solar panels are installed. A major disadvantage of normal Si-based solar cells is that if one solar cell is shaded, the total energy produced by the string of solar cells is lost. Reducing the efficiency of the total system. In resent years, a new technology has been introduced, using thin film solar cells integrated into roofing. Although partial shading doesn't affect this technique as much as Si-based solar cells, the shaded solar cells do not contribute to the energy production. Some years ago a special kind of robot has been developed that automatically mows the lawn. The goal of this thesis is to build an automatic solar panel cleaning robot using a “robomow ” or other robotic vehicle. This robot has to be adapted for use on solar panels, and of course, has its own solar

unknown authors

2007-01-01T23:59:59.000Z

305

References  

E-Print Network (OSTI)

Contribution of residential wood combustion to hourly winter aerosol in Northern Sweden determined by positive matrix factorization

P. Krecl; E. Hedberg Larsson; J. Ström; C. Johansson; Wood Combustion

2008-01-01T23:59:59.000Z

306

Reference:  

E-Print Network (OSTI)

Operator Corporation (CAISO), revised tariff sheets to define the circumstances under which Metered Subsystem resources can use its Reliability Must Run (RMR) units for load following purposes. 1 Specifically, the CAISO revised Section 4.9.13.2 (Load-Following or Non Load-Following Election) of the MRTU Tariff to reflect that an MSS Operator may designate RMR units as load following, and that load following RMR units must be available to the CAISO for dispatch up to the maximum net dependable capacity specified in the RMR contract. The CAISO tariff provides that if the CAISO does not dispatch an RMR load following resource for local reliability needs, the MSS Operator will have the opportunity to participate in the CAISO markets as any other non-RMR load following unit subject to Section 30.5.2.5 (Supply Bids for Metered Subsystems). The revised tariff sheets are accepted for filing to become effective upon implementation of MRTU. 2 1 Load following is typically defined as the use of generation to meet the hour-tohour and daily variations in system load. 2 On March 26, 2008, the Commission issued an order granting the CAISO’s motion to modify the effective date of the MRTU Tariff based on a representation that due to delays in the implementation of MRTU, the March 31, 2008 effective20080612-3013 FERC PDF (Unofficial) 06/12/2008 Docket No. ER06-615-014-2-This filing was noticed on October 10, 2007, with comments, protests, or motions

Bird Llp; Bradley R. Miliauskas

2008-01-01T23:59:59.000Z

307

References  

E-Print Network (OSTI)

Why are estimates of global isoprene emissions so similar (and why is this not so for monoterpenes)?

A. Arneth; R. K. Monson; G. Schurgers; Ü. Niinemets; P. I. Palmer

2008-01-01T23:59:59.000Z

308

References  

Science Conference Proceedings (OSTI)

... Edwards (eds.). 1995. SEER Cancer Statistics Review, 1973-1992: Tables and Graphs. NIH Publication No. 96-2789. Bethesda ...

1998-08-17T23:59:59.000Z

309

References  

Science Conference Proceedings (OSTI)

... Histogram Imaging", Analytical Chemistry 63(4 ... A. (1982) FUNDAMENTALS OF INTERACTIVE ... THE IMAGE PROCESSING HANDBOOK, CRC Press ...

310

References  

Science Conference Proceedings (OSTI)

... 1951) 3277-3278. [24] 'CRC Handbook of Chemistry and Physics' (CRC Press, Boca Raton, FL, 1987). [25] Thomas, JJ ...

2006-06-15T23:59:59.000Z

311

References  

NLE Websites -- All DOE Office Websites (Extended Search)

problem. In: The Second Annual International Conference on Computational Molecular Biology, (Istrail, S, Pevzner, P, Waterman, M, eds) pp. 285-292. ACM New York. Y. Xu, D. Xu,...

312

References  

NLE Websites -- All DOE Office Websites (Extended Search)

Gene-Specific Fragments for Microarrays. In "Currents in Computational Molecular Biology", edited by S. Miyano, R. Shamir and T. Takagi. Universal Academy Press, Inc. Tokyo,...

313

References  

E-Print Network (OSTI)

Los algoritmos evolutivos (AE) son técnicas de optimización basadas en los principios de evolución natural [7]. Aunque los AEs han sido utilizados en solucionar muchos problemas de optimización de manera exitosa, el rendimiento de ellos (medido en tiempo consumido y calidad de la solución producida) depende de la selección adecuada de los parámetros del AE: Operadores genéticos, probabilidades de aplicación de los mismos, tamaño de la población, esquema de selección, etc. Es mas, el proceso de jar tales parámetros es considerado un proceso que consume mucho tiempo [10]. Tomando en cuenta la importancia de este proceso, muchos trabajos de investigación han tratado de manejarlo de diversas maneras [4]. Algunos trabajos han tratado de determinar el valor apropiado de dichos parámetros mediante experimentación extensiva de los mismos en la solución de un conjunto de funciones previamente prede nido [3, 11], o mediante un análisis teórico [5, 1, 9]. Otro conjunto de trabajos, llamados Adaptación de Parámetros (AP), han tratado de eliminar el proceso de selección de parámetros mediante la adaptación de los mismos al tiempo que el algoritmo evolutivo esta siendo ejecutado [2, 8, 13, 9, 12, 6]. En este proyecto se plantea una solución al problema de jar los parámetros mediante técnicas de auto adaptación de parámetros (Meta-evolución). Con tal n, se pretende extender el Algoritmo Evolutivo de Auto Adaptación Híbrida (HAEA por sus siglas en ingles) propuesto por Gomez en [6], de tal manera que no solamente adapte las probabilidades de los operadores genéticos sino los siguientes parámetros: Tamaño de población, mecanismos de selección y operadores genéticos.

Definición Del Problema; A. E. Eiben; R. Hinterding

2007-01-01T23:59:59.000Z

314

References  

E-Print Network (OSTI)

Application An approved SLAC Energized Electrical Work Request and Approval Permit (EEW) is required for all work at SLAC where the work includes assembly, disassembly, or re-arrangement of components while they are energized. Work below 50 volts, as well as testing, troubleshooting, and voltage measuring, are exempt from the required permit per National Fire Protection Association (NFPA) 70E 2004 Edition, Article 130.1(A)(3), provided that adequate work practices and personal protective equipment are used.

unknown authors

2005-01-01T23:59:59.000Z

315

References  

Science Conference Proceedings (OSTI)

... EN, Nagy, G., and Franklin, WR, 'Cracking, Damage, and Fracture in Four ... 05, 'Test Method for the Chemical Shrinkage of Hydraulic Cement Paste ...

2006-08-08T23:59:59.000Z

316

References  

U.S. Energy Information Administration (EIA)

Energy Statistics, ... 8 Elisson, H, and Elvers, E (2001), “Cut-off sampling and estimation,” Statistics Canada International Symposium Series – Proce ...

317

References  

E-Print Network (OSTI)

continuous speech recognition. IEEE Transactions on Pattern Analysis and Machine Intelligence, PAMI-5(2), March 1983. [6] Doug Beeferman, Adam Berger, and John Lafferty. A model of lexical

Steven Abney Functional Elements; Licensing Presented To Glow; J. Bach; T. C. Bell; I. H. Witten; J. L. Bentley; D. D. Sleator; R. E. Tarjan

1989-01-01T23:59:59.000Z

318

TANGO ARRAY An Air Shower Experiment in Buenos Aires  

E-Print Network (OSTI)

A new Air Shower Observatory has been constructed in Buenos Aires during 1999, and commissioned and set in operation in 2000. The observatory consists of an array of four water \\v{C}erenkov detectors, enclosing a geometrical area of $\\sim$ 30.000 m$^{2}$, and is optimized for the observation of cosmic rays in the ``knee'' energy region. The array detects $\\sim$ 250 to $\\sim$ 1500 showers/day, depending on the selected triggering condition. In this paper, the design and construction of the array, and the automatic system for data adquisition, daily calibration, and monitoring, are described. Also, the Monte Carlo simulations performed to develop a shower database, as well as the studies performed using the database to estimate the response and the angular and energy resolutions of the array, are presented in detail.

P. Bauleo; C. Bonifazi; A. Filevich; A. Reguera

2001-04-20T23:59:59.000Z

319

Primary zone air proportioner  

SciTech Connect

An air proportioner is provided for a liquid hydrocarbon fueled gas turbine of the type which is convertible to oil gas fuel and to coal gas fuel. The turbine includes a shell for enclosing the turbine, an air duct for venting air in said shell to a gasifier, and a fuel injector for injecting gasified fuel into the turbine. The air proportioner comprises a second air duct for venting air from the air duct for mixing with fuel from the gasifier. The air can be directly injected into the gas combustion basket along with the fuel from the injector or premixed with fuel from the gasifier prior to injection by the fuel injector.

Cleary, Edward N. G. (San Diego, CA)

1982-10-12T23:59:59.000Z

320

Air Pollution Control (Indiana)  

Energy.gov (U.S. Department of Energy (DOE))

This legislation establishes the Department of Environmental Management and the Air Pollution Control Board, which are tasked with the prevention, abatement, and control of air pollution by all...

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

INTEC Groundwater Monitoring Report 2006  

SciTech Connect

This report summarizes 2006 perched water and groundwater monitoring activities at the Idaho Nuclear Technology and Engineering Center (INTEC) located at the Idaho National Laboratory (INL). During 2006, groundwater samples were collected from a total of 22 Snake River Plain Aquifer (SRPA) monitoring wells, plus six aquifer wells sampled for the Idaho CERCLA Disposal Facility (ICDF) monitoring program. In addition, perched water samples were collected from 21 perched wells and 19 suction lysimeters. Groundwater and perched water samples were analyzed for a suite of radionuclides and inorganic constituents. Laboratory results in this report are compared to drinking water maximum contaminant levels (MCLs). Such comparison is for reference only and it should be noted that the Operable Unit 3-13 Record of Decision does not require that perched water comply with drinking water standards.

J. R. Forbes S. L. Ansley M. Leecaster

2007-02-01T23:59:59.000Z

322

Definition: Equipment Condition Monitor | Open Energy Information  

Open Energy Info (EERE)

Condition Monitor Condition Monitor Jump to: navigation, search Dictionary.png Equipment Condition Monitor A monitoring device that automatically measures and communicates equipment characteristics that are related to the "health" and maintenance of the equipment. These characteristics can include, but are not limited to temperature, dissolved gas, and loading. These devices can automatically generate alarm signals if conditions exceed preset thresholds.[1] Related Terms sustainability References ↑ https://www.smartgrid.gov/category/technology/equipment_condition_monitor [[C LikeLike UnlikeLike You like this.Sign Up to see what your friends like. ategory: Smart Grid Definitions|Template:BASEPAGENAME]] Retrieved from "http://en.openei.org/w/index.php?title=Definition:Equipment_Condition_Monitor&oldid=502601"

323

1985 environmental monitoring report  

Science Conference Proceedings (OSTI)

The environmental monitoring program is designed to determine that BNL facilities operate such that the applicable environmental standards and effluent control requirements have been met. The data were evaluated using the appropriate environmental regulatory criteria. The environmental levels of radioactivity and other pollutants found in the vicinity of BNL during 1985 are summarized in this report. Detailed data are not included in the main body of the report, but are tabulated and presented in Appendix D. The environmental data include external radiation levels; radioactive air particulates; tritium concentrations; the amounts and concentrations of radioactivity in and the water quality of the stream into which liquid effluents are released; the water quality of the potable supply wells; the concentrations of radioactivity in biota from the stream; the concentrations of radioactivity in and the water quality of ground waters underlying the Laboratoy; concentrations of radioactivity in milk samples obtained in the vicinity of the Laboratory; and the 1984 strontium-90 data which was not available for inclusion in the 1984 Environmental Monitoring Report. In 1985, the results of the surveillance program demonstraed that the Laboratory has operated within the applicable environmental standards.

Day, L.E.; Miltenberger, R.P.; Naidu, J.R. (eds.)

1986-04-01T23:59:59.000Z

324

Monitoring, Verification, and Accounting Archived Projects  

NLE Websites -- All DOE Office Websites (Extended Search)

Archived Projects Archived Projects Ambient PM 2.5 Air Sampling & Analysis - The Upper Ohio River Valley Project ATS-Chester Engineers / Desert Research Institute 9/15/1998 Steubenville Comprehensive Air Monitoring Program CONSOL Energy Inc. / Wells Cargo / Air Quality Sciences, Inc. / Wheeling Jesuit University / Saint Vincent College / Franciscan University of Steubenville / Optimal Technologies Inc. / Harvard School of Public Health / Ohio University 3/8/2000 National Carbon Sequestration Database and Geographical Information System (NATCARB) University of Kansas Center for Research 9/27/2000 Environmental Regulatory Analysis Argonne National Laboratory 1/15/2003 Direct Measurement of Mercury Reactions in Coal Power Plant Plumes Electric Power Research Institute / Frontier

325

Microfabricated BTU monitoring device for system-wide natural gas monitoring.  

SciTech Connect

The natural gas industry seeks inexpensive sensors and instrumentation to rapidly measure gas heating value in widely distributed locations. For gas pipelines, this will improve gas quality during transfer and blending, and will expedite accurate financial accounting. Industrial endusers will benefit through continuous feedback of physical gas properties to improve combustion efficiency during use. To meet this need, Sandia has developed a natural gas heating value monitoring instrument using existing and modified microfabricated components. The instrument consists of a silicon micro-fabricated gas chromatography column in conjunction with a catalytic micro-calorimeter sensor. A reference thermal conductivity sensor provides diagnostics and surety. This combination allows for continuous calorimetric determination with a 1 minute analysis time and 1.5 minute cycle time using air as a carrier gas. This system will find application at remote natural gas mining stations, pipeline switching and metering stations, turbine generators, and other industrial user sites. Microfabrication techniques will allow the analytical components to be manufactured in production quantities at a low per-unit cost.

Einfeld, Wayne; Manginell, Ronald Paul; Robinson, Alex Lockwood; Moorman, Matthew Wallace

2005-11-01T23:59:59.000Z

326

Monitoring, Verification and Reporting: Improving Compliance Within Energy  

Open Energy Info (EERE)

Monitoring, Verification and Reporting: Improving Compliance Within Energy Monitoring, Verification and Reporting: Improving Compliance Within Energy Efficient Programs Jump to: navigation, search Tool Summary Name: Monitoring, Verification and Reporting: Improving Compliance Within Energy Efficient Programs Agency/Company /Organization: International Energy Agency Sector: Energy Focus Area: Energy Efficiency Topics: GHG inventory, Policies/deployment programs Resource Type: Guide/manual Website: www.iea.org/papers/pathways/monitoring.pdf Monitoring, Verification and Reporting: Improving Compliance Within Energy Efficient Programs Screenshot References: Monitoring, Verification and Reporting: Improving Compliance Within Energy Efficient Programs[1] This document includes: A brief overview of MVE in the context of S&L programmes.

327

Compressed Air Energy Storage (CAES) Demonstration Newsletter, April 2013  

Science Conference Proceedings (OSTI)

The Compressed Air Energy Storage (CAES) demonstration project includes the phased planning, engineering design, construction, demonstration and performance monitoring of two CAES plants. These plants are envisioned to be the following: 1) a system rated at 300 MWs for up to 10 hours with a below-ground reservoir for bulk energy air storage and 2) a system rated at 15 MWs for 2 hours with above-ground air vessel/piping.This is a critical technology demonstration project, necessary to ...

2013-04-25T23:59:59.000Z

328

Compressed Air Energy Storage Demonstration Newsletter, October 2013  

Science Conference Proceedings (OSTI)

The Compressed Air Energy Storage (CAES) demonstration project includes the phased planning, engineering design, construction, demonstration and performance monitoring of two CAES plants. These plants are envisioned to be the following: 1) a system rated at 300 MWs for up to 10 hours with a below-ground reservoir for bulk energy air storage and 2) a system rated at 15 MWs for 2 hours with above-ground air vessel/piping.This is a critical technology demonstration project, necessary to ...

2013-10-30T23:59:59.000Z

329

Compressed Air Energy Storage (CAES) Demonstration Newsletter, July 2013  

Science Conference Proceedings (OSTI)

The Compressed Air Energy Storage (CAES) demonstration project includes the phased planning, engineering design, construction, demonstration and performance monitoring of two CAES plants. These plants are envisioned to be the following: 1) a system rated at 300 MWs for up to 10 hours with a below-ground reservoir for bulk energy air storage and 2) a system rated at 15 MWs for 2 hours with above-ground air vessel/piping.This is a critical technology demonstration project, necessary to ...

2013-07-29T23:59:59.000Z

330

NETL: Air Quality III Conference  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Quality III Conference - September 12, 2002 Air Quality III Conference - September 12, 2002 Table of Contents Disclaimer Papers and Presentations Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government or any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

331

Verification of clear-air turbulence forecasts June 2002, KNMI  

E-Print Network (OSTI)

to increase potential energy. Under these conditions turbulence will increase in intensity until different weather conditions. It often occurs in relatively clear skies and is then referred to as clear-airVerification of clear-air turbulence forecasts A. Overeem June 2002, KNMI Technisch rapport #12

Stoffelen, Ad

332

Ris Energy Report 6 References Reference list for Chapter 3  

E-Print Network (OSTI)

. (2007). Lessons learned from recent promotion strategies for electricity from renewables in EU countries. Report on progress in renewable electricity. Brussels. (Com(2006) 849 final). 6. Danish Energy authority. References for Chapter 5 1. Brahic, C. (2007). Europe postpones decision on car emissions. New

333

Document Number Q0029500 References  

Office of Legacy Management (LM)

References References 7.0 References 10 CFR 1021. U.S. Department of Energy, "National Environmental Policy Act Implementing Procedures," Code of Federal Regzilations, January 1,2003. 10 CFR 1022. U.S. Department of Energy, "Compliance with Floodplain/Wetlands Environmental Review Requirements," Code ofFederal Regulations, January 1,2003. 33 CFR 323. Corps of Engineers, Department of the Army, "Permits for Discharges of Dredged or Fill Material Into Waters of the United States," Code ofFederal Reglllations, July 1,2002. 40 CFR 192. U.S. Environmental Protection Agency, "Health and Environmental Protection Standards for Uranium and Thorium Mill Tailings," Code of FederalReglrlations, July 1,2002. 40 CFR 230. U.S. Environmental Protection Agency, "Section 404(b)(l) Guidelines for

334

Microsoft Word - references.doc  

Office of Legacy Management (LM)

References May 2005 References May 2005 2004 Site Environmental Report R-1 References Facemire, D. F., S. I. Guttman, D. R. Osborne, and R. H. Sperger, 1990, "Biological and Ecological Site Characterization of the Feed Materials Production Center," FMPC-SUB 018, prepared for Westinghouse Materials Co. of Ohio, Cincinnati, OH. GeoSyntec, 1996, "Impacted Material Placement Plan, On-site Disposal Facility," 20100-PL-007, Revision 3, PCN 2, Prepared for the Fernald Environmental Management Project, DOE, Fernald Area Office, Cincinnati, OH, March. International Commission on Radiological Protection (ICRP), 1994a, "Human Respiratory Tract Model for Radiation Protection," ICRP Publication 66. International Commission on Radiological Protection (ICRP), 1994b, "Protection Against Radon-222

335

Chassis Dynamometer Testing Reference Document  

NLE Websites -- All DOE Office Websites (Extended Search)

Chassis Dynamometer Testing Chassis Dynamometer Testing Reference Document Downloadable Dynamometer Database www.transportation.anl.gov/D3/ Argonne, IL July, 2013 Henning Lohse-Busch, Ph.D. Kevin Stutenberg, Mike Duoba, Eric Rask, Forrest Jehlik and Glenn Keller Advanced Powertrain Research Facility Overview  This is a reference document explaining the facility and processes used to generate the data available from Argonne National Laboratory's (ANL) Downloadable Dynamometer Database (D 3 ).  Content - Advanced Powertrain Research Facility (APRF) - Chassis Dynamometer Testing Basics - Overview of Classic Drive Cycles - Test Condition and Test Sequences - Data Acquisition System and General Instrumentation Overview

336

MOISTURE MONITOR TESTING AND CALIBRATION  

SciTech Connect

ABS>Electrolytic moisture monitors which continuously analyze the moisture content of gases are commercially available. After a period of operation, these instruments may give erroneous readings, frequently because of damage to the electrolytic cell. A gas with a known and reproducible moisture content within the operating range would be useful for making operational response tests on these monltors and for checking their calibration. A paired- hydrate system of a chemical compound exhibits a water vapor pressure that is constant at a constant temperature. ff an unreactive gas is allowed to equilibrate with a paired-hydrate system, the moisture content of the gas is determined by the vapor pressure of the hydrate pair, the total pressure, and the temperature. Hydrated magnesium perchlorate was prepared which contained between four and six moles of water per mole of perchlorate. This material was pulverized lightly then packed into a stainless steel column and 100 cc/minute of air at atmospheric pressure was passed through the bed. The exit air from the column was analyzed with a moisture monitor. A gas residence time of two minutes in the column was found to be sufficient for establishing moisture equilibrium in the exit flow. The moisture content of the exit air was found to vary from 34 to 70 ppm by volume as the temperature of the paired-hydrate system varied from 20 to 28 un. Concent 85% C. Other paired-hydrate systems can extend this range to higher moisture levels. (auth)

Montgomery, C.D.; Googin, J.M.; Phillips, L.R.

1963-03-14T23:59:59.000Z

337

Blue LED for RS Monitor  

E-Print Network (OSTI)

Abstract We report on a design of RS gain monitor system based on blue LED. Gain of each RS PMT is monitored by a LED, which is mounted in front of the PMT window in its _-metal shield. The blue LED well simulates scintillation light with its short pulse and wavelength. The LED is as small as 3 mmOE. The light yield is stable and has small temperature dependence. These are nice properties to install in present RS system with small modification and to operate without air conditioning. In this note we will present outline of our design and test results which demonstrate its desirable properties. 1 Introduction RS gain monitor has been carried out with K_2 events at E787. They are sat- isfactory to monitor long and medium term stability but it is not satisfactory to monitor short term stability and to check PMT and related electronics quickly and frequently. These capabilities are important to reduce setup time and loss time in long E949 run. For these purpose triggerable and stable light source is required at RS system. We consider two types of monitoring system. One is the system which consists of one light source and its light distribution network, such as a Xe lamp with a optical fiber network. It has the advantage that light intensity of the source itself can be monitored and be corrected. But, practically, it is not easy to estimate light output of individual fiber correctly by checking light source and to handle optical fibers, and we have to think out a solution how we introduce lights to RS or its PMT. Also the system is rather expensive and it will take long time to

unknown authors

2000-01-01T23:59:59.000Z

338

Controlling intake of uranium in the workplace: Applications of biokinetic modeling and occupational monitoring data  

Science Conference Proceedings (OSTI)

This report provides methods for interpreting and applying occupational uranium monitoring data. The methods are based on current international radiation protection guidance, current information on the chemical toxicity of uranium, and best available biokinetic models for uranium. Emphasis is on air monitoring data and three types of bioassay data: the concentration of uranium in urine; the concentration of uranium in feces; and the externally measured content of uranium in the chest. Primary Reference guidance levels for prevention of chemical effects and limitation of radiation effects are selected based on a review of current scientific data and regulatory principles for setting standards. Generic investigation levels and immediate action levels are then defined in terms of these primary guidance levels. The generic investigation and immediate actions levels are stated in terms of radiation dose and concentration of uranium in the kidneys. These are not directly measurable quantities, but models can be used to relate the generic levels to the concentration of uranium in air, urine, or feces, or the total uranium activity in the chest. Default investigation and immediate action levels for uranium in air, urine, feces, and chest are recommended for situations in which there is little information on the form of uranium taken into the body. Methods are prescribed also for deriving case-specific investigation and immediate action levels for uranium in air, urine, feces, and chest when there is sufficient information on the form of uranium to narrow the range of predictions of accumulation of uranium in the main target organs for uranium: kidneys for chemical effects and lungs for radiological effects. In addition, methods for using the information herein for alternative guidance levels, different from the ones selected for this report, are described.

Leggett, Richard Wayne [ORNL; Eckerman, Keith F [ORNL; McGinn, Wilson [ORNL; Meck, Dr. Robert A. [U.S. Nuclear Regulatory Commission

2012-01-01T23:59:59.000Z

339

Energy Basics: Solar Air Heating  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

EERE: Energy Basics Solar Air Heating Solar air heating systems use air as the working fluid for absorbing and transferring solar energy. Solar air collectors (devices to heat air...

340

Underground Transmission Systems Reference Book  

Science Conference Proceedings (OSTI)

The Underground Transmission Systems Reference Book covers all stages of cable system design and operation, from initial planning studies to failure analysis. It contains contributions from many of the industry's experts and represents practices from all parts of the United States.

1993-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

The HOL Light System REFERENCE  

E-Print Network (OSTI)

This volume is the reference manual for the HOL Light system. In contrast to the Tutorial, it is mainly intended for reference purposes, though some readers will find it productive to browse through it as part of the learning process. The main entries for the reference manual are generated from the same database that is used by the online HOL Light help system. The entries that follow provide documentation on essentially all the pre-defined ML variable bindings in the HOL Light system. These include: general-purpose functions, such as ML functions for list processing, arithmetic, input/output, and interface configuration; functions for processing the types and terms of the HOL logic and for using the subgoal package; primitive and derived forward inference rules; tactics and tacticals; and pre-proved built-in theorems. The manual entries for these ML identifiers are divided into two chapters. The first chapter is an alphabetical sequence of manual entries for all ML identifiers in the system except those identifiers that are bound to theorems (or pairs of theorems, etc.) The theorems are listed in the second chapter, roughly grouped into sections based on subject matter. Our documentation does not cover basic functions in the OCaml toplevel, such as addition, string concatenation etc. In fact, relatively few native OCaml functions are used, and those are all documented in the Objective CAML Reference Manual:

Tom Melham; Larry Paulson The Typeset

2013-01-01T23:59:59.000Z

342

Isokinetic air sampler  

DOE Patents (OSTI)

An isokinetic air sampler includes a filter, a holder for the filter, an air pump for drawing air through the filter at a fixed, predetermined rate, an inlet assembly for the sampler having an inlet opening therein of a size such that isokinetic air sampling is obtained at a particular wind speed, a closure for the inlet opening and means for simultaneously opening the closure and turning on the air pump when the wind speed is such that isokinetic air sampling is obtained. A system incorporating a plurality of such samplers provided with air pumps set to draw air through the filter at the same fixed, predetermined rate and having different inlet opening sizes for use at different wind speeds is included within the ambit of the present invention as is a method of sampling air to measure airborne concentrations of particulate pollutants as a function of wind speed.

Sehmel, George A. (Richland, WA)

1979-01-01T23:59:59.000Z

343

Climate Reference Network Soilsip01 Product | Data.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Soilsip01 Product Soilsip01 Product Agriculture Community Menu DATA APPS EVENTS DEVELOPER STATISTICS COLLABORATE ABOUT Agriculture You are here Data.gov » Communities » Agriculture » Data Climate Reference Network Soilsip01 Product Dataset Summary Description The U.S. Climate Reference Network is designed specifically to monitor national climate change with best scientific practice and adherence to the accepted principles of climate observations. USCRN hourly soil moisture and soil temperature data are available in the Soilsip01 file set for all stations in the network which are equipped with soil sensors, and have completed an evaluation process currently lasting 240 days from installation. Tags {"Climate Reference Network",USCRN,CRN,"soil moisture","soil temperature","natural resources","environment "}

344

Routine Radiological Environmental Monitoring Plan, Volume 2 Appendices  

SciTech Connect

Supporting material for the plan includes: QUALITY ASSURANCE, ANALYSIS, AND SAMPLING PLAN FOR NTS AIR; QUALITY ASSURANCE, ANALYSIS, AND SAMPLING PLAN FOR WATER ON AND OFF THE NEVADA TEST SITE; QUALITY ASSURANCE, ANALYSIS, AND SAMPLING PLAN FOR NTS BIOTA; QUALITY ASSURANCE, ANALYSIS, AND SAMPLING PLAN FOR DIRECT RADIATION MONITORING; DATA QUALITY OBJECTIVES PROCESS; VADOSE ZONE MONITORING PLAN CHECKLIST.

Bechtel Nevada

1998-12-31T23:59:59.000Z

345

Monitoring-based HVAC Commissioning of an Existing Office  

E-Print Network (OSTI)

LBNL-5940E Monitoring-based HVAC Commissioning of an Existing Office Building for Energy Efficiency thereof or The Regents of the University of California. #12;1 Monitoring-based HVAC Commissioning@lbl.gov, Tel: 1-510-486-4921 Abstract The performance of Heating, Ventilation and Air Conditioning (HVAC

346

Development of a Computer Heating Monitoring System and Its Applications  

E-Print Network (OSTI)

This paper develops a computer heating monitoring system, introduces the components and principles of the monitoring system, and provides a study on its application to residential building heating including analysis of indoor and outdoor air temperature, heating index and energy savings. The results show that the current heating system has a great potential for energy conservation.

Chen, H.; Li, D.; Shen, L.

2006-01-01T23:59:59.000Z

347

Double Shell Tank (DST) Monitor and Control Subsystem Specification  

Science Conference Proceedings (OSTI)

This specification revises the performance requirements and provides references to the requisite codes and standards to be applied during design of the Double-Shell Tank (DST) Monitor and Control Subsystem that supports the first phase of Waste Feed Delivery.

BAFUS, R.R.

2000-11-03T23:59:59.000Z

348

FEMP Technology Brief: Boiler Combustion Control and Monitoring System |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Boiler Combustion Control and Monitoring Boiler Combustion Control and Monitoring System FEMP Technology Brief: Boiler Combustion Control and Monitoring System October 7, 2013 - 9:12am Addthis This composite photo shows technicians observing operation at the monitoring station and making subsequent fine adjustments on combustion system controls Technical staff are making boiler adjustments with the control and monitoring system. Photo courtesy of the Department of Defense's Environmental Security Technology Certification Program. Technology Description A novel combustion control system, along with gas sensors, sets the opening of fuel and air inlets based on flue-gas concentrations. Continuous feedback from measurements of oxygen, carbon monoxide, and nitrogen oxide concentrations enable the control system

349

STATEMENT OF CONSIDERATIONS REQUEST BY AIR LIQUIDE AMERICA, L.P. FOR AN ADVANCED WAIVER OF  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

LIQUIDE AMERICA, L.P. FOR AN ADVANCED WAIVER OF LIQUIDE AMERICA, L.P. FOR AN ADVANCED WAIVER OF PATENT RIGHTS UNDER DOE COOPERATIVE AGREEMENT NO. DE-FC36- 00CH11030; ENTITLED "TUNABLE DIODE LASER SENSORS FOR HARSH COMBUSTION ENVIRONMENTS"; W(A)-04-025; CH-1194 As set out in the attached waiver petition, Air Liquide America, L.P. (ALA) has requested an advanced waiver of domestic and foreign patent rights for all subject inventions made under the above-identified cooperative agreement by its employees. Referring to item 2 of ALA's waiver petition, the purpose of this agreement encompasses the design and evaluation of a multiple gas species diode laser sensor for high temperature harsh industrial process monitoring applications. The work under the agreement is expected to take place over a period of about four years at a total cost of $1,169,529. ALA is

350

Design of a particulate-monitoring network for the Y-12 plant  

SciTech Connect

An Air Quality Monitoring Network Design (AQMND) with multiple objectives is being developed for the Y-12 Plant production facilities. The objectives are: Y-12 facility surveillance; monitoring the transport of Y-12 generated airborne effluents towards either the Oak Ridge National Laboratory or the developed region of the City of Oak Ridge; and monitoring population exposure in residential areas close to the Y-12 Plant. A two step design process was carried out, using the Air Quality Monitor Network Design Model (AQMND) previously used for the Oak Ridge National Laboratory network. In the first step of the design we used existing air quality monitor locations, subjectively designated locations, and grid intersections as a set of potential monitor sites. The priority sites from the first step (modified to account for terrain and accessibility), and subjectively designated sites, were used as the potential monitor sites for the second step of the process which produced the final design recommendations for the monitor network.

Hougland, E.S.; Oakes, T.W.; Underwood, J.N.

1982-01-01T23:59:59.000Z

351

Clean Cities: Clean Cities Reference Materials  

NLE Websites -- All DOE Office Websites (Extended Search)

Reference Materials to Reference Materials to someone by E-mail Share Clean Cities: Clean Cities Reference Materials on Facebook Tweet about Clean Cities: Clean Cities Reference Materials on Twitter Bookmark Clean Cities: Clean Cities Reference Materials on Google Bookmark Clean Cities: Clean Cities Reference Materials on Delicious Rank Clean Cities: Clean Cities Reference Materials on Digg Find More places to share Clean Cities: Clean Cities Reference Materials on AddThis.com... Coordinator Basics Clean Cities Program Structure Reference Materials Technical Support Fundraising Redesignation Outreach Education & Webinars Meetings Reporting Contacts Clean Cities Reference Materials Use these reference materials-including quick-reference documents, publications, websites, and the Clean Cities Coalition Wiki-to develop

352

Urban land use, air toxics and public health: Assessing hazardous exposures at the neighborhood scale  

Science Conference Proceedings (OSTI)

Land use data are increasingly understood as important indicators of potential environmental health risk in urban areas where micro-scale or neighborhood level hazard exposure data are not routinely collected. This paper aims to offer a method for estimating the distribution of air toxics in urban neighborhoods using land use information because actual air monitoring data rarely exist at this scale. Using Geographic Information System spatial modeling tools, we estimate air toxics concentrations across neighborhoods in New York City and statistically compare our model with the US Environmental Protection Agency's National Air Toxic Assessment and air monitoring data across three NYC neighborhoods. We conclude that land use data can act as a good proxy for estimating neighborhood scale air toxics, particularly in the absence of monitoring data. In addition, the paper suggests that land use data can expand the reach of environmental impact assessments that routinely exclude analyses of potential exposures to urban air toxics at the neighborhood scale.

Corburn, Jason [Columbia University, Graduate School of Architecture, Planning and Preservation and School of International and Public Affairs, 400 Avery Hall, 1172 Amsterdam Ave. New York, NY 10027 (United States)]. E-mail: jtc2105@columbia.edu

2007-03-15T23:59:59.000Z

353

Class B monitoring program handbook for southeastern sites with data based on INIT2 software (applicable to heating season)  

DOE Green Energy (OSTI)

This document provides reference information on eight residences located in the southern part of the US which are being monitored under the Class B Passive Solar Monitoring Program. This handbook provides reference information on the sites and basic test conditions for the 1982-1983 winter heating season using software which is identified as INIT2. The manual is intended for use in data analysis work but is limited to this period of time because of basic differences in the control software and the related instrumentation system. This document is separated into individual sections for each site. The following information is provided for each site: (a) Site summary providing information on the structure, the passive solar features, the auxiliary heating system, and other related data; (b) Floor layouts with the sensor locations, etc.; (c) The One Time Value Log which records the results of field tests and calculations to determine the thermal characteristics, air infiltration rate, and other reference data; (d) The Analog/Digital Channel Log which provides calibration data; (e) The Status Channel Log which defines various event sensors; and (f) Program listings as used during the specified time periods during the heating season. Appendix A provides a summary of photographs which have been provided separately as part of the site documentation.

Gustashaw, D. H.

1983-07-01T23:59:59.000Z

354

V-090: Adobe Flash Player / AIR Multiple Vulnerabilities | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0: Adobe Flash Player / AIR Multiple Vulnerabilities 0: Adobe Flash Player / AIR Multiple Vulnerabilities V-090: Adobe Flash Player / AIR Multiple Vulnerabilities February 13, 2013 - 12:14am Addthis PROBLEM: Adobe Flash Player / AIR Multiple Vulnerabilities PLATFORM: Adobe Flash Player versions 11.5.502.149 and prior for Windows and Macintosh Adobe Flash Player versions 11.2.202.262 and prior for Linux Adobe Flash Player versions 11.1.115.37 and prior for Android 4.x Adobe Flash Player versions 11.1.111.32 and prior for Android 3.x and 2.x Adobe AIR versions 3.5.0.1060 and prior Adobe AIR versions 3.5.0.1060 SDK and prior ABSTRACT: Multiple vulnerabilities have been reported in Adobe Flash Player and AIR. REFERENCE LINKS: Vulnerability identifier: APSB13-05 Secunia Advisory SA52166 CVE-2013-0637 CVE-2013-0638 CVE-2013-0639

355

Projected compliance with the PM2.5 National Ambient Air Quality Standards. Final report  

SciTech Connect

In 1997, the State of Maryland had no available ambient Federal Reference Method data on particulate matter less than 2.5 microns in aerodynamic diameter (PM2.5) but did have annual ambient data for particulate matter smaller than 10 microns (PM10) at twenty-four sites. The PM10 data was analyzed in conjunction with local annual and seasonal ZIP code-level emission inventories and with speciated PM2.5 data from four nearby monitors in the IMPROVE network (located in the national parks and wilderness areas) in an effort to predict annual average and seasonal high PM2.5 concentrations at the twenty-four PM10 monitor sites operated from 1992 to 1996. All seasonal high concentrations were predicted to be below the 24-hour PM2.5 National Ambient Air Quality Standard (NAAQS) at the sites operated in Maryland between 1992 and 1996. A geographic analysis of the emission inventories was also performed to evaluate the impact of PM2.5 emissions from Maryland`s power plants on fourteen monitor locations that were predicted to have a reading exceeding the annual NAAQS for any year.

Walsh, K.; Gardner, R.

1999-02-01T23:59:59.000Z

356

Building Technologies Office: Commercial Reference Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Reference Commercial Reference Buildings to someone by E-mail Share Building Technologies Office: Commercial Reference Buildings on Facebook Tweet about Building Technologies Office: Commercial Reference Buildings on Twitter Bookmark Building Technologies Office: Commercial Reference Buildings on Google Bookmark Building Technologies Office: Commercial Reference Buildings on Delicious Rank Building Technologies Office: Commercial Reference Buildings on Digg Find More places to share Building Technologies Office: Commercial Reference Buildings on AddThis.com... About Take Action to Save Energy Activities 179d Tax Calculator Advanced Energy Design Guides Advanced Energy Retrofit Guides Building Energy Data Exchange Specification Buildings Performance Database Data Centers Energy Asset Score

357

FAQS Reference Guide - Transportation and Traffic Management...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Transportation and Traffic Management FAQS Reference Guide - Transportation and Traffic Management This reference guide addresses the competency statements in the September 2002...

358

MHK Reference Model: Relevance to Computer Simulation  

NLE Websites -- All DOE Office Websites (Extended Search)

July 9 th , 2012 SAND Number: 2012-5508P MHK Reference Model: Relevance to Computer Simulation Reference Model Partners Oregon State University NNMREC University of...

359

Category:Water References | Open Energy Information  

Open Energy Info (EERE)

Water References Jump to: navigation, search Pages in category "Water References" This category contains only the following page. A Assessment and Mapping of the Riverine...

360

References and Notes for Astatine ( At )  

Science Conference Proceedings (OSTI)

... Version References and Notes for Astatine ( At ). Ref. ID, Reference, M64a, R. McLaughlin, J. Opt. Soc. Am. 54, 965 (1964).

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

The Consumption of Reference Resources  

E-Print Network (OSTI)

Under the operational restriction of the U(1)-superselection rule, states that contain coherences between eigenstates of particle number constitute a resource. Such resources can be used to facilitate operations upon systems that otherwise cannot be performed. However, the process of doing this consumes reference resources. We show this explicitly for an example of a unitary operation that is forbidden by the U(1)-superselection rule.

G. A. White; J. A. Vaccaro; H. M. Wiseman

2008-11-22T23:59:59.000Z

362

HANFORD WASTE MINERALOGY REFERENCE REPORT  

Science Conference Proceedings (OSTI)

This report lists the observed mineral phases present in the Hanford tanks. This task was accomplished by performing a review of numerous reports that used experimental techniques including, but not limited to: x-ray diffraction, polarized light microscopy, scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, electron energy loss spectroscopy, and particle size distribution analyses. This report contains tables that can be used as a quick reference to identify the crystal phases observed in Hanford waste.

DISSELKAMP RS

2010-06-29T23:59:59.000Z

363

HANFORD WASTE MINEROLOGY REFERENCE REPORT  

Science Conference Proceedings (OSTI)

This report lists the observed mineral phase phases present in the Hanford tanks. This task was accomplished by performing a review of numerous reports using experimental techniques including, but not limited to: x-ray diffraction, polarized light microscopy, scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, electron energy loss spectroscopy, and particle size distribution analyses. This report contains tables that can be used as a quick reference to identify the crystal phases present observed in Hanford waste.

DISSELKAMP RS

2010-06-18T23:59:59.000Z

364

Microgrid cyber security reference architecture.  

SciTech Connect

This document describes a microgrid cyber security reference architecture. First, we present a high-level concept of operations for a microgrid, including operational modes, necessary power actors, and the communication protocols typically employed. We then describe our motivation for designing a secure microgrid; in particular, we provide general network and industrial control system (ICS)-speci c vulnerabilities, a threat model, information assurance compliance concerns, and design criteria for a microgrid control system network. Our design approach addresses these concerns by segmenting the microgrid control system network into enclaves, grouping enclaves into functional domains, and describing actor communication using data exchange attributes. We describe cyber actors that can help mitigate potential vulnerabilities, in addition to performance bene ts and vulnerability mitigation that may be realized using this reference architecture. To illustrate our design approach, we present a notional a microgrid control system network implementation, including types of communica- tion occurring on that network, example data exchange attributes for actors in the network, an example of how the network can be segmented to create enclaves and functional domains, and how cyber actors can be used to enforce network segmentation and provide the neces- sary level of security. Finally, we describe areas of focus for the further development of the reference architecture.

Veitch, Cynthia K.; Henry, Jordan M.; Richardson, Bryan T.; Hart, Derek H.

2013-07-01T23:59:59.000Z

365

Vermont Air Pollution Control Regulations, Ambient Air Quality...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ambient Air Quality Standards (Vermont) Vermont Air Pollution Control Regulations, Ambient Air Quality Standards (Vermont) Eligibility Utility Agricultural Investor-Owned Utility...

366

Vsd Oil Free Air Compressor, Vsd Oil Free Air Compressor ...  

U.S. Energy Information Administration (EIA)

Vsd Oil Free Air Compressor, You Can Buy Various High Quality Vsd Oil Free Air Compressor Products from Global Vsd Oil Free Air Compressor Suppliers ...

367

China Ga Air Compressor, China Ga Air Compressor Products ...  

U.S. Energy Information Administration (EIA)

China Ga Air Compressor, China Ga Air Compressor Suppliers and Manufacturers Directory - Source a Large Selection of Ga Air Compressor Products at ...

368

Oil Free Vsd Air Compressor, Oil Free Vsd Air Compressor ...  

U.S. Energy Information Administration (EIA)

Oil Free Vsd Air Compressor, You Can Buy Various High Quality Oil Free Vsd Air Compressor Products from Global Oil Free Vsd Air Compressor Suppliers ...

369

Screw Type Ac Air Compressor Manufacturers, Screw Type Ac Air ...  

U.S. Energy Information Administration (EIA)

Screw Type Ac Air Compressor, Screw Type Ac Air Compressor Manufacturers & Suppliers Directory - Find here Screw Type Ac Air Compressor Traders, ...

370

Radon Monitoring Results BPA Residential Weatherization Program, Report Number 1.  

SciTech Connect

In October 1984, the Bonneville Power Administration (BPA) began offering free radon monitoring to participants of its regionwide Residential Weatherization Program. The purpose of the radon monitoring is to provide information to participating homeowners or consumers on the average radon concentrations within their residences. This radon concentration information and other information on indoor air quality (IAQ) is provided to assist homeowners on their decision to install ''house-tightening'' weatherization measures. This radon report will present background information on why BPA decided to offer radon monitoring, the procedures used for monitoring, the extent of BPA radon monitoring in the region, and results of this monitoring. Subsequent BPA radon monitoring reports will be produced on a quarterly basis which will include a brief narrative on the radon monitoring and provide a summary of the radon data received to date.

United States. Bonneville Power Administration.

1986-01-01T23:59:59.000Z

371

Reference Inflow Characterization for River Resource Reference Model (RM2)  

DOE Green Energy (OSTI)

Sandia National Laboratory (SNL) is leading an effort to develop reference models for marine and hydrokinetic technologies and wave and current energy resources. This effort will allow the refinement of technology design tools, accurate estimates of a baseline levelized cost of energy (LCoE), and the identification of the main cost drivers that need to be addressed to achieve a competitive LCoE. As part of this effort, Oak Ridge National Laboratory was charged with examining and reporting reference river inflow characteristics for reference model 2 (RM2). Published turbulent flow data from large rivers, a water supply canal and laboratory flumes, are reviewed to determine the range of velocities, turbulence intensities and turbulent stresses acting on hydrokinetic technologies, and also to evaluate the validity of classical models that describe the depth variation of the time-mean velocity and turbulent normal Reynolds stresses. The classical models are found to generally perform well in describing river inflow characteristics. A potential challenge in river inflow characterization, however, is the high variability of depth and flow over the design life of a hydrokinetic device. This variation can have significant effects on the inflow mean velocity and turbulence intensity experienced by stationary and bottom mounted hydrokinetic energy conversion devices, which requires further investigation, but are expected to have minimal effects on surface mounted devices like the vertical axis turbine device designed for RM2. A simple methodology for obtaining an approximate inflow characterization for surface deployed devices is developed using the relation umax=(7/6)V where V is the bulk velocity and umax is assumed to be the near-surface velocity. The application of this expression is recommended for deriving the local inflow velocity acting on the energy extraction planes of the RM2 vertical axis rotors, where V=Q/A can be calculated given a USGS gage flow time-series and stage vs. cross-section area rating relationship.

Neary, Vincent S [ORNL

2011-12-01T23:59:59.000Z

372

Air Conditioning and lungs  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Conditioning and lungs Name: freeman Status: NA Age: NA Location: NA Country: NA Date: Around 1993 Question: What affect does air conditioning have upon the lungs of the...

373

Forest Monitoring for Action (FORMA) | Open Energy Information  

Open Energy Info (EERE)

Forest Monitoring for Action (FORMA) Forest Monitoring for Action (FORMA) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Forest Monitoring for Action (FORMA) Agency/Company /Organization: Center for Global Development Sector: Land, Climate Focus Area: Forestry Topics: GHG inventory, Resource assessment Resource Type: Maps Website: www.cgdev.org/section/initiatives/_active/forestmonitoringforactionfor Cost: Free Forest Monitoring for Action (FORMA) Screenshot References: FORMA[1] "Forest Monitoring for Action (FORMA) uses freely available satellite data to generate rapidly updated online maps of tropical forest clearing, providing useful information for local and national forest conservation programs, as well as international efforts to curb greenhouse gas emissions by paying to keep forests intact."

374

UN-REDD Workshop: Monitoring, Assessment and Verification | Open Energy  

Open Energy Info (EERE)

UN-REDD Workshop: Monitoring, Assessment and Verification UN-REDD Workshop: Monitoring, Assessment and Verification Jump to: navigation, search Tool Summary LAUNCH TOOL Name: UN-REDD Workshop: Monitoring, Assessment and Verification Agency/Company /Organization: United Nations Environment Programme, Food and Agriculture Organization of the United Nations, United Nations Development Programme Sector: Land Focus Area: Forestry Topics: GHG inventory, Policies/deployment programs, Resource assessment Resource Type: Workshop Website: www.un-redd.org/UNREDDProgramme/InternationalSupport/MeasurementReport UN-REDD Workshop: Monitoring, Assessment and Verification Screenshot References: UN-REDD Workshop: Monitoring, Assessment and Verification[1] Background "The specific objectives of the workshop were to develop a roadmap with

375

INSTRUMENTATION FOR ENVIRONMENTAL MONITORING  

E-Print Network (OSTI)

ENVIRONMENTAL MONITORING R. D. McLaughlin, M. S. Hunt, D. L.ENVIRONMENTAL MONITORING R. D. McLaughlin, M. S. Hunt, D. L.

McLaughlin, R.D.

2010-01-01T23:59:59.000Z

376

Method of monitoring CO concentrations in hydrogen feed to a PEM fuel cell  

DOE Green Energy (OSTI)

The CO concentration in the H.sub.2 feed stream to a PEM fuel cell stack is monitored by measuring current and/or voltage behavior patterns from a PEM-probe communicating with the reformate feed stream. Pattern recognition software may be used to compare the current and voltage patterns from the PEM-probe to current and voltage telltale outputs determined from a reference cell similar to the PEM-probe and operated under controlled conditions over a wide range of CO concentrations in the H.sub.2 fuel stream. The PEM-probe is intermittently purged of any CO build-up on the anode catalyst (e.g., by (1) flushing the anode with air, (2) short circuiting the PEM-probe, or (3) reverse biasing the PEM-probe) to keep the PEM-probe at peak performance levels.

Grot, Stephen Andreas (Rochester, NY); Meltser, Mark Alexander (Pittsford, NY); Gutowski, Stanley (Pittsford, NY); Neutzler, Jay Kevin (Rochester, NY); Borup, Rodney Lynn (East Rochester, NY); Weisbrod, Kirk (Los Alamos, NM)

2000-01-01T23:59:59.000Z

377

APPENDIX. TERMS OF REFERENCE Terms of Reference for the 41st Northeast Stock Assessment Workshop  

E-Print Network (OSTI)

projection) using the same configurations as those used in the 2004 SAW Southern Demersal Working Group (WG) assessment update. 2. Estimate biological reference points derived by yield and SSB per recruit analysis and by stock-recruitment modeling, following the procedures adopted by the 2002 Working Group on Re-Evaluation of Biological Reference Points for New England Groundfish. 3. Consider the recommendations of the MAFMC Science and Statistical Committee (SSC) 2001 peer review of the summer flounder Overfishing Definition in developing the analyses described in TOR 2. The major recommendations were to explore other proxies (besides Fmax) to FMSY, to continue stock-recruitment model development as additional stock-recruit estimates become available, and to monitor and utilize new data on the population dynamics of summer flounder (e.g., age, growth, and maturity) as they become available. 4. Review, evaluate and report on the status of the SARC/Working Group research recommendations offered in previous SARC and WG reviewed assessments. B. Bluefish- ASMFC Technical Committee/Assessment Subcommittee 1. Evaluate adequacy, appropriateness and uncertainty of fishery-dependent and fisheryindependent

Woods Hole; A. Summer; Flounder Saw; Southern Demersal

2005-01-01T23:59:59.000Z

378

Emergency Responder Radioactive Material Quick Reference Sheet...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Transportation Emergency Preparedness Program (TEPP) Emergency Responder Radioactive Material Quick Reference Sheet...

379

Indoor air radon  

SciTech Connect

This review concerns primarily the health effects that result from indoor air exposure to radon gas and its progeny. Radon enters homes mainly from the soil through cracks in the foundation and other holes to the geologic deposits beneath these structures. Once inside the home the gas decays (half-life 3.8 d) and the ionized atoms adsorb to dust particles and are inhaled. These particles lodge in the lung and can cause lung cancer. The introduction to this review gives some background properties of radon and its progeny that are important to understanding this public health problem as well as a discussion of the units used to describe its concentrations. The data describing the health effects of inhaled radon and its progeny come both from epidemiological and animal studies. The estimates of risk from these two data bases are consistent within a factor of two. The epidemiological studies are primarily for hard rock miners, although some data exist for environmental exposures. The most complete studies are those of the US, Canadian, and Czechoslovakian uranium miners. Although all studies have some deficiencies, those of major importance include uranium miners in Saskatchewan, Canada, Swedish iron miners, and Newfoundland fluorspar miners. These six studies provide varying degrees of detail in the form of dose-response curves. Other epidemiological studies that do not provide quantitative dose-response information, but are useful in describing the health effects, include coal, iron ore and tin miners in the UK, iron ore miners in the Grangesburg and Kiruna, Sweden, metal miners in the US, Navajo uranium miners in the US, Norwegian niobian and magnitite miners, South African gold and uranium miners, French uranium miners, zinc-lead miners in Sweden and a variety of small studies of environmental exposure. An analysis of the epidemiological studies reveals a variety of interpretation problem areas.172 references.

Cothern, C.R.

1990-01-01T23:59:59.000Z

380

PVWatts Version 1 Technical Reference  

DOE Green Energy (OSTI)

The NREL PVWatts(TM) calculator is a web application developed by the National Renewable Energy Laboratory (NREL) that estimates the electricity production of a grid-connected photovoltaic system based on a few simple inputs. PVWatts combines a number of sub-models to predict overall system performance, and makes several hidden assumptions about performance parameters. This technical reference details the individual sub-models, documents assumptions and hidden parameters, and explains the sequence of calculations that yield the final system performance estimation.

Dobos, A. P.

2013-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Air Pollution- Local Air Quality (Ontario, Canada)  

Energy.gov (U.S. Department of Energy (DOE))

The Air Pollution regulation administered by the Ministry of the Environment enforces compliance to the standards set in the Ontario law. The law is phased in, with portions taking effect in 2010,...

382

New Robust References! | OpenEI Community  

Open Energy Info (EERE)

New Robust References! New Robust References! Home > Groups > OpenEI Community Central Jweers's picture Submitted by Jweers(83) Contributor 7 August, 2013 - 18:23 citation citing developer formatting reference Semantic Mediawiki wiki Check out the new Reference Form. Adding a reference object to OpenEI using this form is the most complete way to cite a reference. After providing the name of your reference, the form will ask for your document type. Depending on what you choose, it will ask for the information necessary to build the proper MLA citation for the reference. This citation is then available semantically as a property of the reference and can be embedded in other pages! The Cite template was developed to help with this. You can site a reference by including {{Cite|Asimov's Story|I,_Robot}}, where I,_Robot

383

1983 environmental monitoring report  

Science Conference Proceedings (OSTI)

The environmental levels of radioactivity and other pollutants found in the vicinity of BNL during 1983 are summarized. The amounts of radioactivity and other pollutants released in airborne and liquid effluents from Laboratory facilities to the environment are also indicated. The environmental data includes external radiation levels; radioactivity of air particulates; tritium concentrations; the amounts and concentrations of radioactivity in and the water quality of the stream into which liquid effluents are released; the concentrations of radioactivity in biota from the stream; the concentrations of radioactivity in and the water quality of ground waters underlying the Laboratory; and concentrations of radioactivity in milk samples obtained in the vicinity of the Laboratory. The amounts of radioactivity released in airborne and liquid effluents from laboratory facilities to the environment were within allowable standards as stipulated in DOE Order 5480.1. Other pollutants, such as metals, organic compounds, etc., in the effluents released from the Laboratory were well below federal, state and local standards as applied to site specific conditions. 34 references, 9 figures, 17 tables.

Day, L.E.; Naidu, J.R. (eds.)

1984-06-01T23:59:59.000Z

384

Thin Air Breathing  

NLE Websites -- All DOE Office Websites (Extended Search)

Thin Air Breathing Thin Air Breathing Name: Amy Location: N/A Country: N/A Date: N/A Question: Why is it hard to breathe in thin air? What health dangers do mountain climbers face at high altitudes? Replies: Among the obvious dangers of losing ones footing, the oxygen available in the air is considerable less at higher altitudes. If I recall correctly, 21% of the atmosphere at standard temperature and pressure at sea level is composed of oxygen. This is less at higher altitudes. One can lose consciousness and even die in an oxygen deficient environment with changes from oxygen content to lower than 19.5%. This can unfortunate effect can occur within minutes. Dr. Myron The air is not really thin at high altitudes. The problem is that air pressure is lower. As altitude increases, air pressure decreases. In order for your lungs to fill with air, the air pressure in your lungs has to be less than the pressure of the air outside your lungs. Air moves from areas of higher pressure to lower pressure. As your diaphragm (the muscle that separates your chest cavity from your abdominal cavity) moves downward, the size of your chest cavity increases. This decreases the pressure in your chest and air flows in. When the diaphragm is up, it puts pressure on the chest cavity and the pressure in the lungs is greater than outside the lungs. Air flows out. This is an example of Boyle's Law. The movement of the diaphragm is controlled by the brainstem. Anyway-the reason that it is harder for some people to breathe at higher altitudes is that the air pressure differences aren't as great between the inside of the lungs and outside.

385

Modern Performance Monitoring  

Science Conference Proceedings (OSTI)

Today's diverse and decentralized computer world demands new thinking about performance monitoring and analysis.

Mark Purdy

2006-02-01T23:59:59.000Z

386

Control Measure Title Reference Number *  

E-Print Network (OSTI)

exhaustive search for emissions reductions to use in meeting federal Clean Air Act requirements for this 2008 PM2.5 Plan. Chapter 6 details the District’s process for developing control measures for reducing emissions of primary PM2.5 and PM2.5 precursors. This Appendix presents the product of this process: a master list of all candidate control measure ideas identified and evaluated for this plan. After assembling Appendix I, the District then screened the candidate measures into several categories: high priority measures to be implemented in the years immediately following plan adoption; measures that might be implemented in future years to allow for expected technology development; and those measures that require further study to identify when they could be implemented and what reductions they could achieve. Candidate control measure descriptions in Appendix I have the following major components:! Title and Number

unknown authors

2008-01-01T23:59:59.000Z

387

Microwave Plasma Monitoring System For Real-Time Elemental Analysis  

NLE Websites -- All DOE Office Websites (Extended Search)

Microwave Plasma Monitoring System For Real-Time Elemental Analysis Microwave Plasma Monitoring System For Real-Time Elemental Analysis Microwave Plasma Monitoring System For Real-Time Elemental Analysis The invention apparatus can also be used to monitor for the presence of halogens, sulfur and silicon. Available for thumbnail of Feynman Center (505) 665-9090 Email Microwave Plasma Monitoring System For Real-Time Elemental Analysis There has been invented a process for analyzing ambient air in a microwave induced plasma without use of an additional carrier gas. There has also been invented an apparatus for analyzing ambient air, other sample gas, or nebulized and desolvated liquids wherein a novel arrangement of plasma gas and sample gas conduits is used to enhance dependability of the plasma. This apparatus embodiment of the invention has a concentric arrangement of

388

FAA Air Traffic Organization Safety Management | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

FAA Air Traffic Organization Safety Management FAA Air Traffic Organization Safety Management FAA Air Traffic Organization Safety Management September 20, 2012 Presenter: Mark DeNicuolo, Manager Performance and Analyses Air Traffic Organization Safety and Technical Training Federal Aviation Administration Topics Covered: En Route centers handle 40.5 million aircraft per year FAA/contract towers handle: - 51.2 million airport operations - 39 million instrument operations 732 million passenger enplanements Over 5,000 civil, public-use airports Approximately 33,300 ATO employees - More than 15,000 air traffic controllers - More than 7,000 technicians and engineers 21 ARTCCs, 513 ATCTs, 17 FSSs, 3 AFSSs FAA Air Traffic Organization Safety Management More Documents & Publications FAQS Reference Guide - Aviation Manager

389

Clean Air and Climate Protection Software 2009 | Open Energy Information  

Open Energy Info (EERE)

Clean Air and Climate Protection Software 2009 Clean Air and Climate Protection Software 2009 Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Clean Air and Climate Protection Software 2009 Focus Area: Low Carbon Communities Topics: Opportunity Assessment & Screening Website: www.icleiusa.org/tools/cacp-2009/cacp-software-2009/ Equivalent URI: cleanenergysolutions.org/content/clean-air-and-climate-protection-soft CACP 2009 is a one-stop emissions management tool that calculates and tracks emissions and reductions of greenhouse gases (carbon dioxide, methane, nitrous oxide) and criteria air pollutants (NOx, SOx, carbon monoxide, volatile organic compounds, PM10, PM 2.5) associated with electricity, fuel use, and waste disposal. References Retrieved from "http://en.openei.org/w/index.php?title=Clean_Air_and_Climate_Protection_Software_2009&oldid=51434

390

Compressed Air Energy Storage (CAES) | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Compressed Air Energy Storage (CAES) Jump to: navigation, search Contents 1 Introduction 2 Technology Description 3 Plants 4 References Introduction Compressed air energy storage (CAES) is a way to store energy that is generated at night and deliver the energy during the day to meet peak demand. This is performed by compressing air and storing it during periods of excess electricity and expanding the air through a turbine when electricity is needed. Technology Description Diabatic Diabatic compressed air energy storage is what the two existing compressed air energy storage facilities currently employ. This method is

391

CRYSTALLINE CERAMIC WASTE FORMS: REFERENCE FORMULATION REPORT  

Science Conference Proceedings (OSTI)

The research conducted in this work package is aimed at taking advantage of the long term thermodynamic stability of crystalline ceramics to create more durable waste forms (as compared to high level waste glass) in order to reduce the reliance on engineered and natural barrier systems. Durable ceramic waste forms that incorporate a wide range of radionuclides have the potential to broaden the available disposal options and to lower the storage and disposal costs associated with advanced fuel cycles. Assemblages of several titanate phases have been successfully demonstrated to incorporate radioactive waste elements, and the multiphase nature of these materials allows them to accommodate variation in the waste composition. Recent work has shown that they can be successfully produced from a melting and crystallization process. The objective of this report is to explain the design of ceramic host systems culminating in a reference ceramic formulation for use in subsequent studies on process optimization and melt property data assessment in support of FY13 melter demonstration testing. The waste stream used as the basis for the development and testing is a combination of the projected Cs/Sr separated stream, the Trivalent Actinide - Lanthanide Separation by Phosphorous reagent Extraction from Aqueous Komplexes (TALSPEAK) waste stream consisting of lanthanide fission products, the transition metal fission product waste stream resulting from the transuranic extraction (TRUEX) process, and a high molybdenum concentration with relatively low noble metal concentrations. In addition to the combined CS/LN/TM High Mo waste stream, variants without Mo and without Mo and Zr were also evaluated. Based on the results of fabricating and characterizing several simulated ceramic waste forms, two reference ceramic waste form compositions are recommended in this report. The first composition targets the CS/LN/TM combined waste stream with and without Mo. The second composition targets with CS/LN/TM combined waste stream with Mo and Zr removed. Waste streams that contain Mo must be produced in reducing environments to avoid Cs-Mo oxide phase formation. Waste streams without Mo have the ability to be melt processed in air. A path forward for further optimizing the processing steps needed to form the targeted phase assemblages is outlined in this report. Processing modifications including melting in a reducing atmosphere, and controlled heat treatment schedules are anticipated to improve the targeted elemental partitioning.

Brinkman, K.; Fox, K.; Marra, J.

2012-05-15T23:59:59.000Z

392

NETL: Gasification Systems Reference Shelf  

NLE Websites -- All DOE Office Websites (Extended Search)

Shelf Shelf Gasification Systems Reference Shelf TABLE OF CONTENTS Brochures Conferences and Workshops Gasification Systems Projects National Map Gasification Systems Projects and Performers Gasification Systems Project Portfolio Gasifipedia Multi-phase Flow with Interphase eXchange (MFIX) Patents Program Presentations Project Information Projects Summary Table by State Solicitations Systems and Industry Analyses Studies Technical Presentations & Papers Technology Readiness Assessment (Comprehensive Report | Overview Report) Video, Images & Photos Gasification Plant Databases CD Icon Request Gasification Technologies Information on a CD. Gasification RSS Feed Subscribe to the Gasification RSS Feed to follow website updates. LinkedIn DOE Gasification Program Group Subscribe to the LinkedIn DOE Gasification Program group for more information and discussion.

393

The Nuclear Science References Database  

E-Print Network (OSTI)

The Nuclear Science References (NSR) database together with its associated Web interface, is the world's only comprehensive source of easily accessible low- and intermediate-energy nuclear physics bibliographic information for more than 210,000 articles since the beginning of nuclear science. The weekly-updated NSR database provides essential support for nuclear data evaluation, compilation and research activities. The principles of the database and Web application development and maintenance are described. Examples of nuclear structure, reaction and decay applications are specifically included. The complete NSR database is freely available at the websites of the National Nuclear Data Center http://www.nndc.bnl.gov/nsr and the International Atomic Energy Agency http://www-nds.iaea.org/nsr.

Pritychenko, B; Singh, B; Totans, J

2013-01-01T23:59:59.000Z

394

NUCLEAR SCIENCE REFERENCES CODING MANUAL  

Science Conference Proceedings (OSTI)

This manual is intended as a guide for Nuclear Science References (NSR) compilers. The basic conventions followed at the National Nuclear Data Center (NNDC), which are compatible with the maintenance and updating of and retrieval from the Nuclear Science References (NSR) file, are outlined. The NSR database originated at the Nuclear Data Project (NDP) at Oak Ridge National Laboratory as part of a project for systematic evaluation of nuclear structure data.1 Each entry in this computer file corresponds to a bibliographic reference that is uniquely identified by a Keynumber and is describable by a Topic and Keywords. It has been used since 1969 to produce bibliographic citations for evaluations published in Nuclear Data Sheets. Periodic additions to the file were published as the ''Recent References'' issues of Nuclear Data Sheets prior to 2005. In October 1980, the maintenance and updating of the NSR file became the responsibility of the NNDC at Brookhaven National Laboratory. The basic structure and contents of the NSR file remained unchanged during the transfer. In Chapter 2, the elements of the NSR file such as the valid record identifiers, record contents, and text fields are enumerated. Relevant comments regarding a new entry into the NSR file and assignment of a keynumber are also given in Chapter 2. In Chapter 3, the format for keyword abstracts is given followed by specific examples; for each TOPIC, the criteria for inclusion of an article as an entry into the NSR file as well as coding procedures are described. Authors preparing Keyword abstracts either to be published in a Journal (e.g., Nucl. Phys. A) or to be sent directly to NNDC (e.g., Phys. Rev. C) should follow the illustrations in Chapter 3. The scope of 1See W.B.Ewbank, ORNL-5397 (1978). the literature covered at the NNDC, the categorization into Primary and Secondary sources, etc., is discussed in Chapter 4. Useful information regarding permitted character sets, recommended abbreviations, etc., is given in the Appendices. The NSR database has been in existence for decades, and responsibility for its upkeep has passed through many hands. Those familiar with the contents of NSR will note that not all of the formats and conventions discussed in this manual have always been adhered to. In recent years, however, these conventions have been followed fairly consistently, and it is expected that the preparation of new entries will follow these guidelines. The most up-to-date information about NSR contents and policies can be found at the NSR web site: http://www.nndc.bnl.gov/nsr. This manual is an update to BNL-NCS-51800 (Rev. 08/96) by S. Ramavataram and C.L. Dunford. Discussions with Mark Kellett of the IAEA are gratefully acknowledged, as are comments and suggestions from the NNDC staff and members of the U.S. Nuclear Data Program. This manuscript has been authored by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH1-886 with the U.S.Department of Energy.

WINCHELL,D.F.

2007-04-01T23:59:59.000Z

395

Influence of seasonal variations on ambient air quality in Al Jahra governorate, in the state of Kuwait  

Science Conference Proceedings (OSTI)

This work analyzes the air pollution yearlong hourly mean continuous data from one of the monitoring station located at the top of polyclinic in Al-Jahra city in the State of Kuwait. The measurements cover major pollutants such as carbon monoxide, methane, ... Keywords: Al-Jahra, air pollution, continuous monitoring, seasonal variations, traffic

Raslan Alenezi

2011-02-01T23:59:59.000Z

396

Dehumidification and cooling loads from ventilation air  

SciTech Connect

The importance of controlling humidity in buildings is cause for concern, in part, because of indoor air quality problems associated with excess moisture in air-conditioning systems. But more universally, the need for ventilation air has forced HVAC equipment (originally optimized for high efficiency in removing sensible heat loads) to remove high moisture loads. To assist cooling equipment and meet the challenge of larger ventilation loads, several technologies have succeeded in commercial buildings. Newer technologies such as subcool/reheat and heat pipe reheat show promise. These increase latent capacity of cooling-based systems by reducing their sensible capacity. Also, desiccant wheels have traditionally provided deeper-drying capacity by using thermal energy in place of electrical power to remove the latent load. Regardless of what mix of technologies is best for a particular application, there is a need for a more effective way of thinking about the cooling loads created by ventilation air. It is clear from the literature that all-too-frequently, HVAC systems do not perform well unless the ventilation air loads have been effectively addressed at the original design stage. This article proposes an engineering shorthand, an annual load index for ventilation air. This index will aid in the complex process of improving the ability of HVAC systems to deal efficiently with the amount of fresh air the industry has deemed useful for maintaining comfort in buildings. Examination of typical behavior of weather shows that latent loads usually exceed sensible loads in ventilation air by at least 3:1 and often as much as 8:1. A designer can use the engineering shorthand indexes presented to quickly assess the importance of this fact for a given system design. To size those components after they are selected, the designer can refer to Chapter 24 of the 1997 ASHRAE Handbook--Fundamentals, which includes separate values for peak moisture and peak temperature.

Harriman, L.G. III [Mason-Grant, Portsmouth, NH (United States); Plager, D. [Quantitative Decision Support, Portsmouth, NH (United States); Kosar, D. [Gas Research Inst., Chicago, IL (United States)

1997-11-01T23:59:59.000Z

397

A Reference Design for Residential Energy Gateways: Development and  

NLE Websites -- All DOE Office Websites (Extended Search)

A Reference Design for Residential Energy Gateways: Development and A Reference Design for Residential Energy Gateways: Development and Implications Speaker(s): Daniel Arnold Date: October 28, 2011 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Janie Page Recent advances in communications, policy, and the installation of smart meters in residences across America has opened the realm of the residence to the possibility of advanced electrical load monitoring and control. With no concrete standards or roadmaps governing communications and capabilities, a fractured market of Gateways, IHDs (In Home Displays), load control switches, and smart appliances has emerged in an attempt to take advantage of this burgeoning opportunity. What results from this mixture is a lack of interoperability amongst products, which limits consumer

398

Air Pollution Project: Scenario  

NLE Websites -- All DOE Office Websites (Extended Search)

Project Summary HELP Index Summary Scenario Internet Links Student Pages SubjectContent Area: ScienceChemistry, Environment - Air Pollution Target Audience: High school chemistry...

399

Air Resources Board  

E-Print Network (OSTI)

The Air Resources Board (the Board or ARB) will conduct a public hearing at the time and place noted below to consider amendments to the Verifkztion

unknown authors

2003-01-01T23:59:59.000Z

400

Air Resources Board  

E-Print Network (OSTI)

The Air Resources Board (the Board or ARB) will conduct a public hearing at the time and place noted below to consider amendments to the Verification

unknown authors

2003-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Movements in air conditioning.  

E-Print Network (OSTI)

??Movements in Air Conditioning is a collection of poems that explores the obstacles inherent in creating a new sense of home in a country that… (more)

Hitt, Robert D. (Robert David)

2013-01-01T23:59:59.000Z

402

Adsorption air conditioner  

DOE Patents (OSTI)

A solar powered air conditioner using the adsorption process is constructed with its components in a nested cylindrical array for compactness and ease of operation.

Rousseau, Jean L. I. (Redondo Beach, CA)

1979-01-01T23:59:59.000Z

403

Indoor Air Quality Group  

Science Conference Proceedings (OSTI)

... CONTAM has been used at NIST to study the indoor air quality impacts of HVAC systems in single-family residential buildings, ventilation in large ...

2011-10-31T23:59:59.000Z

404

Room Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

of Superefficient Room Air Conditioners year month keywords appliance energy efficiency energy efficiency incentives Market Transformation standards url https isswprod lbl gov...

405

Air Pollution Controls  

Energy.gov (U.S. Department of Energy (DOE))

Various statutes within the Wisconsin Legislative Documents relate to air pollution control. These statutes describe zoning, permitting, and emissions regulations for hazardous and non-hazardous...

406

Forced air fireplace furnace  

Science Conference Proceedings (OSTI)

The design of heating system for buildings including a fireplace with an open front hearth for burning firewood, a chimney extending from the upper portion of the hearth, a metal firebox being open in the front and closed on the sides and back, a plenum chamber within and surrounding the sides and back of the metal firebox and the chimney lower portion, a horizontal heat distribution chamber positioned in the building attic and communicating at one end with the plenum chamber is described. An air distribution duct connects to the other end of the air distributing chamber, the duct extending to discharge heated air to a place in the building remote from the fireplace. A fan is placed in the horizontal air distributing chamber, and a return air duct extends from selected place in the building and communicates with the plenum chamber lower portion so that the fan draws air through the return air duct, through the plenum chamber around the firebox where the air is heated, through the horizontal distribution chamber, and out through the distribution duct for circulation of the heated air within the building.

Bruce, R.W.; Gorman, R.E.

1980-10-28T23:59:59.000Z

407

NETL: Ambient Monitoring - Contribution of Semi-volatile Organic Material  

NLE Websites -- All DOE Office Websites (Extended Search)

Semi-volatile Organics in PM Semi-volatile Organics in PM This project is a cooperative effort between Brigham Young University (BYU) and researchers from the DOE-NETL Office of Science and and Engineering Research to determine the contribution of semi-volatile particulate organic compounds (SVOC) to total ambient suspended fine particulate mass at the NETL-Pittsburgh air monitoring facility. Project funding comes from DOE‘s University Coal Research (UCR) program. The hypothesis of the project is that fine particulate mass will be significantly under-determined in urban environments using single filter samplers such as the PM2.5 Federal Reference Method (FRM) because of the loss of semi-volatile organic compounds (SVOC) from the particles during sampling and storage. It is postulated that fine particulate mass, including the semi-volatile fine particulate organic species, are an appropriate surrogate for the components of fine particles which are associated with observed mortality and morbidity effects in epidemiological studies. Further, it is postulated that the most important fraction of the semi-volatile organic material with respect to exacerbation of health problems will be semi-volatile secondary compounds formed from reactions of volatile organic material with ozone and nitrogen oxides. Under-determination of these semi-volatile species will tend to over emphasize the importance of non-volatile fine particulate components such as sulfate or may reduce the significance of correlations with measured health effects.

408

Generating Referring Expressions that Involve Gradable Properties  

Science Conference Proceedings (OSTI)

This article examines the role of gradable properties in referring expressions from the perspective of natural language generation. First, we propose a simple semantic analysis of vague descriptions (i.e., referring expressions that contain gradable ...

Kees van Deemter

2006-06-01T23:59:59.000Z

409

Forecasting with Reference to a Specific Climatology  

Science Conference Proceedings (OSTI)

Seasonal forecasts are most commonly issued as anomalies with respect to some multiyear reference period. However, different seasonal forecasting centers use different reference periods. This paper shows that for near-surface temperature, ...

Emily Wallace; Alberto Arribas

2012-11-01T23:59:59.000Z

410

Continuous aqueous tritium monitor  

DOE Patents (OSTI)

An apparatus for a selective on-line determination of aqueous tritium concentration is disclosed. A moist air stream of the liquid solution being analyzed is passed through a permeation dryer where the tritium and moisture and selectively removed to a purge air stream. The purge air stream is then analyzed for tritium concentration, humidity, and temperature, which allows computation of liquid tritium concentration.

McManus, Gary J. (Idaho Falls, ID); Weesner, Forrest J. (Idaho Falls, ID)

1989-05-30T23:59:59.000Z

411

Environment/Climate Standard Reference Materials Portal  

Science Conference Proceedings (OSTI)

... more. Reference Materials and Standards for Fossil Fuels, Electric Utility Emissions, and Coal Combustion By-Products ...

2012-12-27T23:59:59.000Z

412

SPC/E Water Reference Calculations  

Science Conference Proceedings (OSTI)

SPC/E Water Reference Calculations - Ewald Summation. In ... 5. Sample Configurations of SPC/E Water Molecules. Four ...

2013-09-16T23:59:59.000Z

413

NIST Standard Reference Material/SRM product  

Science Conference Proceedings (OSTI)

*. Bookmark and Share. How do I order/price a NIST Standard Reference Material/SRM product? Ordering information is ...

2012-11-26T23:59:59.000Z

414

Bioscience & Health Standard Reference Materials Portal  

Science Conference Proceedings (OSTI)

... Our goal is to develop advanced measurement tools and standards for measuring ... see all Bioscience & Health Standard Reference Materials ...

2013-08-08T23:59:59.000Z

415

Evaluation of Methods to Identify Boiler Air Inleakage Sources  

Science Conference Proceedings (OSTI)

The information contained in this technical update report represents a first-of-a-kind study to evaluate different methods used to identify boiler air inleakage. The study begins to outline the cost and benefits of using those different methods in addition to describing their application. The collection and assemblage of this information will provide a reference for plant engineering and management personnel as their units experience the problems associated with boiler air inleakage. Through the use of t...

2011-09-23T23:59:59.000Z

416

Application of an SVM-based regression model to the air quality study at local scale in the Avilés urban area (Spain)  

Science Conference Proceedings (OSTI)

The objective of this study is to build a regression model of air quality by using the support vector machine (SVM) technique in the Aviles urban area (Spain) at local scale. Hazardous air pollutants or toxic air contaminants refer to any substance that ... Keywords: Air quality, Machine learning, Pollutant substances, Support vector regression

A. SuáRez SáNchez; P. J. GarcíA Nieto; P. Riesgo FernáNdez; J. J. Del Coz DíAz; F. J. Iglesias-RodríGuez

2011-09-01T23:59:59.000Z

417

ILC cryogenic systems reference design  

SciTech Connect

A Global Design Effort (GDE) began in 2005 to study a TeV scale electron-positron linear accelerator based on superconducting radio-frequency (RF) technology, called the International Linear Collider (ILC). In early 2007, the design effort culminated in a reference design for the ILC, closely based on the earlier TESLA design. The ILC will consist of two 250 GeV linacs, which provide positron-electron collisions for high energy physics research. The particle beams will be accelerated to their final energy in superconducting niobium RF cavities operating at 2 kelvin. At a length of about 12 km each, the main linacs will be the largest cryogenic systems in the ILC. Positron and electron sources, damping rings, and beam delivery systems will also have a large number and variety of other superconducting RF cavities and magnets, which require cooling at liquid helium temperatures. Ten large cryogenic plants with 2 kelvin refrigeration are envisioned to cool the main linacs and the electron and positron sources. Three smaller cryogenic plants will cool the damping rings and beam delivery system components predominately at 4.5 K. This paper describes the cryogenic systems concepts for the ILC.

Peterson, T.J.; Geynisman, M.; Klebaner, A.; Theilacker, J.; /Fermilab; Parma, V.; Tavian, L.; /CERN

2008-01-01T23:59:59.000Z

418

Argon Purification Reference and Recommendation  

Science Conference Proceedings (OSTI)

This engineering note is a reference for future consideration on the purification of argon. The original concern was for the possibility of argon contamination from components in the cryostats over long-term storage. An argon purification system could also be useful for purifying the contents of the argon dewar. The general conclusion is that most of the systems researched are too expensive at this time, but the recommended choice would be Centorr Furnaces. There were three basic types of purification systems which were to be considered. The first was the molecular sieve. This method would have been the preferred one, because it was claimed that it could purify liquid argon, removing liquid oxygen from the argon. However, none of the commercial companies researched provided this type of purification for use with liquid argon. Most companies said that this type of purification was impossible, and tests at IB-4 confirmed this. The second system contained a copper oxide to remove gaseous oxygen from argon gas. The disadvantage of this system wass that the argon had to be heated to a gas, and then cooled back down to liquid. The third system was similar to the second, except that it used tungsten or another material like titanium. This system also needed to heat the argon to gas, however the advantage of this system was that it supposedly removed all contaminants, that is, everything except for inert gases. Of the three systems, the third is the type manufactured by Centorr Furnaces, which uses a titanium charge.

Wu, J.; /Fermilab

1991-05-23T23:59:59.000Z

419

MathCAD model for the estimation of cost and main characteristics of air-cushion vehicles in the preliminary design stage  

E-Print Network (OSTI)

In the naval architecture terminology, the term ACV (Air Cushion Vehicle) refers to this category of vehicles, in which a significant portion of the weight (or all the weight) is supported by forces arising from air pressures ...

Gougoulidis, Georgios

2005-01-01T23:59:59.000Z

420

Form PI-1 General Application for Air Preconstruction Permit | Open Energy  

Open Energy Info (EERE)

General Application for Air Preconstruction Permit General Application for Air Preconstruction Permit Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Reference Material: Form PI-1 Air Preconstruction Permit Details Activities (0) Areas (0) Regions (0) Abstract: Unavailable Author(s): Unknown Published: Texas Commission on Environmental Quality, Date Unknown Document Number: Unavailable DOI: Unavailable Source: View Original Document Retrieved from "http://en.openei.org/w/index.php?title=Form_PI-1_General_Application_for_Air_Preconstruction_Permit&oldid=631449" Category: Reference Materials What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 1863640201

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Reference framework for E-participation projects  

Science Conference Proceedings (OSTI)

Accommodating the various requirements from distinct perspectives in e-participation calls for a holistic engineering approach for e-participation systems analysis and design. This paper presents research results towards a reference framework for e-participation ... Keywords: E-participation, reference framework, reference model

Sabrina Scherer; Maria A. Wimmer

2011-08-01T23:59:59.000Z

422

2006 LANL Radionuclide Air Emissions Report  

SciTech Connect

This report describes the impacts from emissions of radionuclides at Los Alamos National Laboratory (LANL) for calendar year 2006. This report fulfills the requirements established by the Radionuclide National Emissions Standards for Hazardous Air Pollutants (Rad-NESHAP). This report is prepared by LANL's Rad-NESHAP compliance team, part of the Environmental Protection Division. The information in this report is required under the Clean Air Act and is being reported to the U.S. Environmental Protection Agency (EPA). The highest effective dose equivalent (EDE) to an off-site member of the public was calculated using procedures specified by the EPA and described in this report. LANL's EDE was 0.47 mrem for 2006. The annual limit established by the EPA is 10 mrem per year. During calendar year 2006, LANL continuously monitored radionuclide emissions at 28 release points, or stacks. The Laboratory estimates emissions from an additional 58 release points using radionuclide usage source terms. Also, LANL uses a network of air samplers around the Laboratory perimeter to monitor ambient airborne levels of radionuclides. To provide data for dispersion modeling and dose assessment, LANL maintains and operates meteorological monitoring systems. From these measurement systems, a comprehensive evaluation is conducted to calculate the EDE for the Laboratory. The EDE is evaluated as any member of the public at any off-site location where there is a residence, school, business, or office. In 2006, this location was the Los Alamos Airport Terminal. The majority of this dose is due to ambient air sampling of plutonium emitted from 2006 clean-up activities at an environmental restoration site (73-002-99; ash pile). Doses reported to the EPA for the past 10 years are shown in Table E1.

David P. Fuehne

2007-06-30T23:59:59.000Z

423

Recirculating electric air filter  

DOE Patents (OSTI)

An electric air filter cartridge has a cylindrical inner high voltage eleode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

Bergman, Werner (Pleasanton, CA)

1986-01-01T23:59:59.000Z

424

Portable oven air circulator  

DOE Patents (OSTI)

A portable air circulating apparatus for use in cooking ovens which is used to create air currents in the oven which transfer heat to cooking foodstuffs to promote more rapid and more uniform cooking or baking, the apparatus including a motor, fan blade and housing of metallic materials selected from a class of heat resistant materials.

Jorgensen, Jorgen A. (Bloomington, MN); Nygren, Donald W. (Minneapolis, MN)

1983-01-01T23:59:59.000Z

425

Corrosion monitoring apparatus  

DOE Patents (OSTI)

A corrosion monitoring device in an aqueous system which includes a formed crevice and monitoring the corrosion of the surfaces forming the crevice by the use of an a-c electrical signal.

Isaacs, Hugh S. (Shoreham, NY); Weeks, John R. (Stony Brook, NY)

1980-01-01T23:59:59.000Z

426

Portal radiation monitor  

DOE Patents (OSTI)

A portal radiation monitor combines 0.1% FAR with high sensitivity to special nuclear material. The monitor utilizes pulse shape discrimination, dynamic compression of the photomultiplier output and scintillators sized to maintain efficiency over the entire portal area.

Kruse, Lyle W. (Albuquerque, NM)

1985-01-01T23:59:59.000Z

427

Metropolitan New York in the greenhouse: Air quality and health effects  

SciTech Connect

A variety of potential effects on human health resulting from climate change have been identified in several assessments. According to an international panel{sup 1} they include direct effects of extreme temperatures on cardiovascular deaths, secondary effects due to vector-borne diseases or crop yields, and tertiary effects such as those that might arise from conflicts over freshwater supplies. To this fist we add the secondary effects of increased air pollution, which may result either directly from climate change or indirectly from increased air conditioning loads and the corresponding pollutant emissions from electric utilities. Higher ozone concentrations have been linked to increased ambient temperatures by both theory and observations of monitoring data. A similar association with particulate matter has been limited to observations, thus far. The pollution-heat linkage has been recognized before` but health effects have not been evaluated in terms of predictions of the joint effects of both agents. This paper has been prepared in two sections. First, we discuss the ozone situation with special reference to the Northeast Corridor and New York. In the second section, we present estimates of the health effects of climate change on New York and discuss some mitigation options.

Kleinman, L.I.; Lipfert, F.

1996-01-01T23:59:59.000Z

428

Meeting the Air Leakage  

NLE Websites -- All DOE Office Websites (Extended Search)

Meeting the Air Leakage Meeting the Air Leakage Requirements of the 2012 IECC The U.S. Department of Energy (DOE) recognizes the enormous potential that exists for improving the energy efficiency, safety and comfort of homes. The newest edition of the International Energy Conservation Code ® (IECC) (2012) sets the bar higher for energy efficiency, and new air sealing requirements are one of the key new provisions. This guide is a resource for understanding the new air leakage requirements in the 2012 IECC and suggestions on how these new measures can be met. It also provides information from Building America's Air Sealing Guide, Best Practices and case studies on homes that are currently meeting the provisions. The 2012 IECC and a few International Residential Code (IRC) requirements are referenced throughout the guide.

429

Energy Crossroads: Ventilation, Infiltration & Indoor Air Quality |  

NLE Websites -- All DOE Office Websites (Extended Search)

Ventilation, Infiltration & Indoor Air Quality Ventilation, Infiltration & Indoor Air Quality Suggest a Listing Air Infiltration and Ventilation Centre (AIVC) The AIVC fulfills its objectives by providing a range of services and facilities which include: Information, Technical Analysis, Technical Interchange, and Coordination. American Conference of Governmental Industrial Hygienists (ACGIH) The ACGIH offers high quality technical publications and learning opportunities. Americlean Services Corp. (ASC) ASC is a certified SBA 8(a) engineering/consulting firm specializing in HVAC contamination detection, abatement, and monitoring. In addition to highly professional ductwork cleaning and HVAC cleaning services, ASC offers a wide range of other engineering/ consulting/ management services

430

Compressed Air Energy Storage Demonstration Newsletter, July 2011  

Science Conference Proceedings (OSTI)

The Compressed Air Energy Storage (CAES) demonstration project includes the phased planning, engineering design, construction, demonstration and performance monitoring of two CAES plants. These plants are envisioned to be the following: 1) a system rated at 300 MWs for up to 10 hours with a below-ground reservoir for bulk energy air storage and 2) a system rated at 15 MWs for 2 hours with above-ground air vessel/piping. This is a critical technology demonstration project, necessary to enable higher penet...

2011-07-31T23:59:59.000Z

431

Compressed Air Energy Storage Demonstration Newsletter, October 2011  

Science Conference Proceedings (OSTI)

The Compressed Air Energy Storage (CAES) demonstration project includes the phased planning, engineering design, construction, demonstration and performance monitoring of two CAES plants. These plants are envisioned to be the following: 1) a system rated at 300 MWs for up to 10 hours with a below-ground reservoir for bulk energy air storage and 2) a system rated at 15 MWs for 2 hours with above-ground air vessel/piping. This is a critical technology demonstration project, necessary to enable higher penet...

2011-10-24T23:59:59.000Z

432

Compressed Air Energy Storage Demonstration Newsletter, January 2012  

Science Conference Proceedings (OSTI)

The Compressed Air Energy Storage (CAES) demonstration project includes the phased planning, engineering design, construction, demonstration and performance monitoring of two CAES plants. These plants are envisioned to be the following: 1) a system rated at 300 MWs for up to 10 hours with a below-ground reservoir for bulk energy air storage and 2) a system rated at 15 MWs for 2 hours with above-ground air vessel/piping. This is a critical technology demonstration project, necessary to enable higher penet...

2012-01-30T23:59:59.000Z

433

Commercial Reference Buildings | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Commercial Reference Buildings Jump to: navigation, search DOE developed Commercial Reference Buildings which provide descriptions for whole building analysis using EnergyPlus. There are 16 building types and three categories that apply to all building types. The commercial reference buildings were developed across 16 reference locations. Contents 1 Building Types 2 Construction Categories 3 Climate Zones Used to Create Reference Buildings 4 References Building Types DOE developed 16 Commercial Reference Building Types[1] , which represent approximately 70% of the commercial buildings in the U.S. [2]. Whole

434

Template:Reference | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Template Edit History Facebook icon Twitter icon » Template:Reference Jump to: navigation, search This is the Reference template. To define/cite a new reference using CSE citation format, please use the Reference form. Parameters Name - The name or title of the reference material Document_type - The type of reference material (allowable values) InfographicType - The type of infographic if Info Grahpic/Map/Chart is the selected Document_type ThesisDissertation - Determines thesis or dissertation (Thesis/Dissertation) Authors - Comma delimited list of people who authored the reference material (required for Books, Conference Papers and Proceedings, Journal

435

Form:Reference | Open Energy Information  

Open Energy Info (EERE)

Form Form Edit History Facebook icon Twitter icon » Form:Reference Jump to: navigation, search Input the title of a Reference below. If the reference already exists, you will be able to edit its information. Add/Edit Reference The text entered into this field will be used as the name of the reference; for example, the title of a book or name of the journal article. Example references Claritas Rise, Mars- Pre-Tharsis Magmatism? An Improved Equilibrium-Kinetics Speciation Algorithm For Redox Reactions In Variably Saturated Subsurface Flow Systems True-Temperature Determination Of Geothermal Reservoirs ... further results This form and reference requirements are based on the Council of Science Editors (CSE) (author-date) citation style. For more details about this

436

International Council for Local Environmental Initiatives (ICLEI) Clean Air  

Open Energy Info (EERE)

International Council for Local Environmental Initiatives (ICLEI) Clean Air International Council for Local Environmental Initiatives (ICLEI) Clean Air and Climate Protection Software Tools Jump to: navigation, search Tool Summary Name: International Council for Local Environmental Initiatives (ICLEI) Clean Air and Climate Protection Software Tools Agency/Company /Organization: International Council for Local Environmental Initiatives Sector: Climate Focus Area: - Waste to Energy, Buildings, Greenhouse Gas, Offsets and Certificates, Transportation Phase: Determine Baseline, Evaluate Options, Develop Goals, Prepare a Plan Resource Type: Software/modeling tools User Interface: Desktop Application Website: www.icleiusa.org/action-center/tools/cacp-software Cost: Paid References: CACP Software 2009[1] Local Government Operations Protocol[2]

437

The NIST Standard Reference Photometer for Ozone ...  

Science Conference Proceedings (OSTI)

... Upgrade and Inter-comparison of the US Environmental Protection Agencies ... FR, Proceedings of the Air and Waste Management Association's 97th ...

2012-10-02T23:59:59.000Z

438

Draft NISTIR 7924, Reference Certificate Policy  

Science Conference Proceedings (OSTI)

... securely, each communicating part of the network may have ... modules, shall be protected from theft, loss, and 3 ... 5.1.3 Power and Air Conditioning 31 ...

2013-04-25T23:59:59.000Z

439

Synergistic Use of MODIS and AIRS in a Variational Retrieval of Cloud Parameters  

Science Conference Proceedings (OSTI)

The Moderate Resolution Imaging Spectroradiometer (MODIS) and the Atmospheric Infrared Sounder (AIRS) measurements from the Earth Observing System's (EOS's) Aqua satellite enable global monitoring of the distribution of clouds. MODIS is able to ...

Jun Li; W. Paul Menzel; Wenjian Zhang; Fengying Sun; Timothy J. Schmit; James J. Gurka; Elisabeth Weisz

2004-11-01T23:59:59.000Z

440

Estimation of Meteorological Parameters for Air Quality Management: Coupling of Sodar Data with Simple Numerical Models  

Science Conference Proceedings (OSTI)

In this paper an attempt is made to couple sodar data and simple numerical models to calculate the wind field and the boundary layer parameters that are relevant to air quality monitoring and studies. For this purpose, a diagnostic, mass-...

Dimitrios Melas; Giulia Abbate; Dias Haralampopoulos; Alexandros Kelesidis

2000-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Compressed Air Audits: A Holistic Approach -Addressing the Air System as a Whole  

E-Print Network (OSTI)

First, consider the Independent Auditor. Plant management should consider using an independent auditor without ties to equipment sales who has experience with a variety of manufacturing facilities and can provide strong references documenting proven energy savings. The quality and comprehensiveness of manufacturing facilities, and therefore audits, vary widely and it is important to consider experience. Compressed Air Technologies has audited nearly 200 manufacturing facilities since our inception in 1996. Compressed Air Technologies is the preferred air energy services provider for Georgia Pacific Corporation, INVISTA Chemicals and a primary energy partner with KRAFT Foods, among others. Compressed Air Technologies has no OEM affiliation of any kind and will provide recommendations that are system-neutral and commercially impartial. Compressed Air Technologies (CAT) is an international energy reduction and system optimization services corporation. CAT is a totally independent business structure with no ties or affiliations with any air compressor manufacturers -we are free of OEM restrictions. Our strict adherence to an independent approach related to compressed air and gas system assessments allows for unbiased commentary and recommendations, regardless of the brand or equipment type currently utilized in your plant. The majority of our competitors have either 1) equipment to sell and/or,2) existing equipment on the site to protect. In both situations, the interests of the client is not the paramount issue. Independent auditors should have no obvious or hidden agenda. CAT compressed air audit services are in essence, holistic. The analysis of your facility compressed air and gases systems is all-inclusive and consists of an engineered assessment beginning at the air compressor equipment area inside your facility and finishing at point-of-use consumption points. CAT engineers utilize a variety of instruments to collect data from all critical, relevant areas of the compressed air and gas systems. From air compressor blow off loss to the cost of the always present distribution/ piping system leaks, each individual loss or inefficiency is measured, analyzed, quantified and catalogued. CAT engineers then compile all of the collected data to create a total current profile report of your facility operations including an assigned cost to each discovered inefficiency. A typical audit results in identification of 25 to 60 percent or more in total system operational waste, which includes energy costs, maintenance costs, and all matters related to operating your compressed gas systems. It is not unusual to discover half of what you pay for compressed air operations is wasted due to inefficient utilization and operation of this important utility.

Shaver, D.

2011-01-01T23:59:59.000Z

442

Consultation for the H/sub 2/S and meteorological monitoring program of the Ente Nazionale per l'Energia Electtrica (ENEL). Final report  

DOE Green Energy (OSTI)

Assistance in setting up a program for monitoring air quality in the vicinity of geothermal development in Larderello's vapor-dominated fields is reviewed. (MHR)

Ruff, R.E.; Cavanagh, L.A.; Collis, R.T.H.

1980-05-01T23:59:59.000Z

443

Seismic Imaging and Monitoring  

SciTech Connect

I give an overview of LANL's capability in seismic imaging and monitoring. I present some seismic imaging and monitoring results, including imaging of complex structures, subsalt imaging of Gulf of Mexico, fault/fracture zone imaging for geothermal exploration at the Jemez pueblo, time-lapse imaging of a walkway vertical seismic profiling data for monitoring CO{sub 2} inject at SACROC, and microseismic event locations for monitoring CO{sub 2} injection at Aneth. These examples demonstrate LANL's high-resolution and high-fidelity seismic imaging and monitoring capabilities.

Huang, Lianjie [Los Alamos National Laboratory

2012-07-09T23:59:59.000Z

444

Seismic Imaging and Monitoring  

SciTech Connect

I give an overview of LANL's capability in seismic imaging and monitoring. I present some seismic imaging and monitoring results, including imaging of complex structures, subsalt imaging of Gulf of Mexico, fault/fracture zone imaging for geothermal exploration at the Jemez pueblo, time-lapse imaging of a walkway vertical seismic profiling data for monitoring CO{sub 2} inject at SACROC, and microseismic event locations for monitoring CO{sub 2} injection at Aneth. These examples demonstrate LANL's high-resolution and high-fidelity seismic imaging and monitoring capabilities.

Huang, Lianjie [Los Alamos National Laboratory

2012-07-09T23:59:59.000Z

445

Independent Oversight Assessment of Environmental Monitoring at the Idaho National Laboratory Site, May 2010  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Assessment of Assessment of Environmental Monitoring at the Idaho National Laboratory Site May 2010 Office of Independent Oversight Office of Health, Safety and Security Office of Health, Safety and Security HSS Independent Oversight Abbreviations i Executive Summary iii 1 Introduction 1 2 Positive Attributes 3 3 Program Enhancements 5 4 INL Site Environmental Monitoring Program 7 4.1 Overall Assessment 7 4.2 Crosscutting Concerns and Recommendations 7 4.3 Media-Specific Perspectives and Recommendations 11 4.3.1 Air Monitoring 11 4.3.2 Liquid Effluent Monitoring 12 4.3.3 Soil Monitoring 12 4.3.4 Agricultural Products and Game Animals Monitoring 13

446

Future Perfect Partnering with California Air Resources Board (CARB) | Open  

Open Energy Info (EERE)

Future Perfect Partnering with California Air Resources Board (CARB) Future Perfect Partnering with California Air Resources Board (CARB) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Future Perfect Partnering with California Air Resources Board (CARB) Agency/Company /Organization: Future Perfect Sector: Climate Focus Area: GHG Inventory Development, Greenhouse Gas Topics: GHG inventory, Low emission development planning, -LEDS Resource Type: Case studies/examples, Training materials Complexity/Ease of Use: Advanced Website: www.gpstrategiesltd.com/divisions/future-perfect/ Language: English References: Future Perfect Partnering with California Air Resources Board (CARB)[1] Logo: Future Perfect Partnering with California Air Resources Board (CARB) In the winter of 2008, Future Perfect (FP) began collaborating with the

447

Regulations of the Arkansas Operating Air Permit Program (Arkansas) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Regulations of the Arkansas Operating Air Permit Program (Arkansas) Regulations of the Arkansas Operating Air Permit Program (Arkansas) Regulations of the Arkansas Operating Air Permit Program (Arkansas) < Back Eligibility Commercial Construction Fuel Distributor Industrial Investor-Owned Utility Retail Supplier Utility Program Info State Arkansas Program Type Environmental Regulations Siting and Permitting Provider Department of Environmental Quality The Regulations of the Arkansas Air Operating Program are adopted in accordance with the provisions of Part UU of the Arkansas Water and Air Pollution Control Act, Arkansas Code Annotated 8-4-101, and will be referred to in this description as "program", "regulations" and "regulation No. 26". The regulations are intended to meet the requirements of title of

448

Field Monitoring Protocol: Heat Pump Water Heaters  

SciTech Connect

This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

Sparn, B.; Earle, L.; Christensen, D.; Maguire, J.; Wilson, E.; Hancock, E.

2013-02-01T23:59:59.000Z

449

Abatement of Air Pollution: Prohibition of Air Pollution (Connecticut...  

Open Energy Info (EERE)

DEEP Air Management Department Department of Energy and Environmental Protection Division Environmental Protection Division; Bureau of Air Management Address 79 Elm Street Place...

450

Air ejector augmented compressed air energy storage system  

DOE Patents (OSTI)

Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air pressure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

1980-01-01T23:59:59.000Z

451

Abatement of Air Pollution: Prohibition of Air Pollution (Connecticut)  

Energy.gov (U.S. Department of Energy (DOE))

All air pollution not otherwise covered by these regulations is prohibited. Stationary sources which cause air pollution must be operated in accordance with all applicable emissions standards and...

452

Study of the Influence of Air Supply Temperature on Air Distribution in the Run-through Large Space Architecture  

E-Print Network (OSTI)

The article introduces the concept and features of run-through large space. By using CFD technology, the paper simulates a velocity field and temperature field in the important air conditioned zone of China's science and technology museum (new museum) under winter operating conditions. At the same time, the indoor air flow regulations are summarized according to the simulation results. On the above basis, a new solution for airflow control of the connection in a run-through large space is put forward. The conclusion of this paper will offer guidance and reference for the air conditioning design of homogeneous architecture.

Tian, Z.; Zhang, J.; Zhu, M.; He, J.

2006-01-01T23:59:59.000Z

453

Air Shower Simulations  

SciTech Connect

Air shower simulations are a vital part of the design of air shower experiments and the analysis of their data. We describe the basic features of air showers and explain why numerical simulations are the appropriate approach to model the shower simulation. The CORSIKA program, the standard simulation program in this field, is introduced and its features, performance and limitations are discussed. The basic principles of hadronic interaction models and some gerneral simulation techniques are explained. Also a brief introduction to the installation and use of CORSIKA is given.

Alania, Marco; Gomez, Adolfo V. Chamorro [Centro de Tecnologias de Informacion y Comunicaciones, Universidad Nacional de Ingenieria, Lima (Peru); Araya, Ignacio J. [Departamento de Astronomia y Astrofisica, Pontificia Universidad Catolica de Chile, Av. Vicuna Mackenna 4860, Santiago (Chile); Huerta, Humberto Martinez; Flores, Alejandra Parra [Facultad de Ciencias Fisico Matematicas, Benemerita Universidad Autonoma de Puebla, Puebla (Mexico); Knapp, Johannes [School of Physics and Astronomy, University of Leeds, Leeds LS2 9JT (United Kingdom)

2009-04-30T23:59:59.000Z

454

Air heating system  

DOE Patents (OSTI)

A self-starting, fuel-fired, air heating system including a vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with the provision of heat exchanger and circuitry for cooling the condensed fluid output from the pump prior to its return to the vapor generator.

Primeau, John J. (19800 Seminole Rd., Euclid, OH 44117)

1983-03-01T23:59:59.000Z

455

Environmental Monitoring Plan  

Science Conference Proceedings (OSTI)

This Environmental Monitoring Plan was written to fulfill the requirements of Department of Energy (DOE) Order 5400.1 and DOE Environmental Regulatory Guide DOE/EH 0173T. This Plan documents the background, organizational structure, and methods used for effluent monitoring and environmental surveillance at Sandia National Laboratories/California. The design, rationale, and historical results of the environmental monitoring system are discussed in detail. Throughout the Plan, recommendations for improvements to the monitoring system are made. This revision to the Environmental Monitoring Plan was written to document the changes made to the Monitoring Program during 1992. Some of the data (most notably the statistical analyses of past monitoring data) has not been changed.

Holland, R.C. [Science Applications International Corp., San Diego, CA (United States)

1993-07-01T23:59:59.000Z

456

Solar and Thermal Radiation Errors on Upper-Air Radiosonde Temperature Measurements  

Science Conference Proceedings (OSTI)

Atmospheric temperature and humidity profiles are important for weather prediction, but climate change has increased the interest in upper-air observations asking for very high-quality reference measurements. This paper discusses an experimental ...

R. Philipona; A. Kräuchi; G. Romanens; G. Levrat; P. Ruppert; E. Brocard; P. Jeannet; D. Ruffieux; B. Calpini

2013-10-01T23:59:59.000Z

457

Solar and Thermal Radiation Errors on Upper-Air Radiosonde Temperature Measurements  

Science Conference Proceedings (OSTI)

Atmospheric temperature and humidity profiles are important for weather prediction, but climate change has increased the interest in upper-air observations asking for very high quality reference measurements. Here we show an experimental approach ...

R. Philipona; A. Kräuchi; G. Romanens; G. Levrat; P. Ruppert; E. Brocard; P. Jeannet; D. Ruffieux; B. Calpini

458

Urbanization Effects on Observed Surface Air Temperature Trends in North China  

Science Conference Proceedings (OSTI)

A dataset of 282 meteorological stations including all of the ordinary and national basic/reference surface stations of north China is used to analyze the urbanization effect on surface air temperature trends. These stations are classified into ...

Guoyu Ren; Yaqing Zhou; Ziying Chu; Jiangxing Zhou; Aiying Zhang; Jun Guo; Xuefeng Liu

2008-03-01T23:59:59.000Z

459

Oxygen sensor for monitoring gas mixtures containing hydrocarbons  

DOE Patents (OSTI)

A gas sensor measures O.sub.2 content of a reformable monitored gas containing hydrocarbons H.sub.2 O and/or CO.sub.2, preferably in association with an electrochemical power generation system. The gas sensor has a housing communicating with the monitored gas environment and carries the monitored gas through an integral catalytic hydrocarbon reforming chamber containing a reforming catalyst, and over a solid electrolyte electrochemical cell used for sensing purposes. The electrochemical cell includes a solid electrolyte between a sensor electrode that is exposed to the monitored gas, and a reference electrode that is isolated in the housing from the monitored gas and is exposed to a reference gas environment. A heating element is also provided in heat transfer communication with the gas sensor. A circuit that can include controls operable to adjust operations via valves or the like is connected between the sensor electrode and the reference electrode to process the electrical signal developed by the electrochemical cell. The electrical signal varies as a measure of the equilibrium oxygen partial pressure of the monitored gas. Signal noise is effectively reduced by maintaining a constant temperature in the area of the electrochemical cell and providing a monitored gas at chemical equilibria when contacting the electrochemical cell. The output gas from the electrochemical cell of the sensor is fed back into the conduits of the power generating system.

Ruka, Roswell J. (Pittsburgh, PA); Basel, Richard A. (Pittsburgh, PA)

1996-01-01T23:59:59.000Z

460

Oxygen sensor for monitoring gas mixtures containing hydrocarbons  

DOE Patents (OSTI)

A gas sensor measures O{sub 2} content of a reformable monitored gas containing hydrocarbons, H{sub 2}O and/or CO{sub 2}, preferably in association with an electrochemical power generation system. The gas sensor has a housing communicating with the monitored gas environment and carries the monitored gas through an integral catalytic hydrocarbon reforming chamber containing a reforming catalyst, and over a solid electrolyte electrochemical cell used for sensing purposes. The electrochemical cell includes a solid electrolyte between a sensor electrode that is exposed to the monitored gas, and a reference electrode that is isolated in the housing from the monitored gas and is exposed to a reference gas environment. A heating element is also provided in heat transfer communication with the gas sensor. A circuit that can include controls operable to adjust operations via valves or the like is connected between the sensor electrode and the reference electrode to process the electrical signal developed by the electrochemical cell. The electrical signal varies as a measure of the equilibrium oxygen partial pressure of the monitored gas. Signal noise is effectively reduced by maintaining a constant temperature in the area of the electrochemical cell and providing a monitored gas at chemical equilibria when contacting the electrochemical cell. The output gas from the electrochemical cell of the sensor is fed back into the conduits of the power generating system. 4 figs.

Ruka, R.J.; Basel, R.A.

1996-03-12T23:59:59.000Z

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Feature - Lithium-air Batteries  

NLE Websites -- All DOE Office Websites (Extended Search)

Develop Lithium-Air Battery Li-air Li-air batteries hold the promise of increasing the energy density of Li-ion batteries by as much as five to 10 times. But that potential will...

462

Clean coal reference plants: Atmospheric CFB. Topical report, Task 1  

Science Conference Proceedings (OSTI)

The Clean Coal Technology Demonstration Program is a government and industry cofunded technology development effort to demonstrate a new generation of innovative coal utilization processes in a series of full-scale facilities. The goal of the program is to provide the US energy marketplace with a number of advanced, more efficient and environmentally responsive coal-using technologies. The Morgantown Energy Technology Center (METC) has the responsibility for monitoring the CCT Projects within certain technology categories, which correspond to the center`s areas of technology development, including atmospheric fluidized bed combustion, pressurized fluidized bed combustion, integrated gasification combined cycle, mild gasification, and industrial applications. A measure of success in the CCT program will be the commercial acceptance of the new technologies being demonstrated. The dissemination of project information to potential users is being accomplished by producing a series of reference plant designs which will provide the users a basis for the selection of technologies applicable to their future energy requirements. As a part of DOE`s monitoring and evaluation of the CCT Projects, Gilbert/Commonwealth (G/C) has been contracted to assist in this effort by producing the design of a commercial size Reference Plant, utilizing technologies developed in the CCT Program. This report, the first in a series, describes the design of a 400 MW electric power plant, utilizing an atmospheric pressure, circulating fluidized bed combustor (ACFB) similar to the one which was demonstrated at Colorado-Ute`s Nucla station, funded in Round 1 of the CCT Program. The intent of the reference plant design effort was to portray a commercial power plant with attributes considered important to the utility industry. The logical choice for the ACFB combustor was Pyropower since they supplied the ACFB for the Nucla Project.

Rubow, L.N.; Harvey, L.E.; Buchanan, T.L.; Carpenter, R.G.; Hyre, M.R.; Zaharchuk, R.

1992-06-01T23:59:59.000Z

463

Literature Review on Underfloor Air Distribution (UFAD) Systems  

E-Print Network (OSTI)

Various sources and search engines were used to find the technical research and literature by using specific keywords to search for the relevant reports or browsing through the list of documents. First, the 227 of references from the book “Underfloor Air Distribution (UFAD) Design Guide” by Fred S. Bauman were used to start searching literature. His references include papers, articles, and web references presenting major contributions to the understanding and development of UFAD technology and design. Other literature search methods were utilized. Below is the list of sources.

Im, P.; Cho, S.; Haberl, J. S.

2006-01-10T23:59:59.000Z

464

Continuous aqueous tritium monitor  

DOE Patents (OSTI)

An apparatus for a selective on-line determination of aqueous tritium concentration is disclosed. A moist air stream of the liquid solution being analyzed is passed through a permeation dryer where the tritium and moisture are selectively removed to a purge air stream. The purge air stream is then analyzed for tritium concentration, humidity, and temperature, which allows computation of liquid tritium concentration. 2 figs.

McManus, G.J.; Weesner, F.J.

1987-10-19T23:59:59.000Z

465

Portfolio Manager Technical Reference: Thermal Conversion Factors...  

NLE Websites -- All DOE Office Websites (Extended Search)

able to monitor electricity consumption on a continuous basis. Based on your particular energy suppliers and onsite systems, you may have a variety of different meter types that...

466

Commercial Reference Buildings | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Buildings » Research Projects » Commercial Reference Buildings » Research Projects » Commercial Reference Buildings Commercial Reference Buildings The U.S. Department of Energy (DOE), in conjunction with three of its national laboratories, developed commercial reference buildings, formerly known as commercial building benchmark models. These reference buildings play a critical role in the program's energy modeling software research by providing complete descriptions for whole building energy analysis using EnergyPlus simulation software. There are 16 building types that represent approximately 70% of the commercial buildings in the U.S., according to the report published by the National Renewable Energy Laboratory titled U.S. Department of Energy Commercial Reference Building Models of the National Building Stock. These

467

Existing Commercial Reference Buildings Constructed Before 1980 |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Existing Commercial Reference Buildings Constructed Before 1980 Existing Commercial Reference Buildings Constructed Before 1980 Existing Commercial Reference Buildings Constructed Before 1980 The files on this page contain commercial reference building models for existing buildings constructed before 1980, organized by building type and location. These U.S. Department of Energy (DOE) reference buildings are complete descriptions for whole building energy analysis. You can also return to a summary of building types and climate zones and information about other building vintages. These files are updated regularly. There are two versions of these files on this page. Version 1.3_5.0 was updated September 27, 2010 and Version 1.4_7.2 was updated November 13, 2012. You can also view related resources: an archive of past reference buildings files

468

Air Carrier Flight Operations  

E-Print Network (OSTI)

Most air carriers operate under a system of prioritized goals including safety, customer service (on-time departures and arrivals) and operating economics. The flight operations department is responsible for the safe and ...

Midkif, Alan H.

469

AIR RESOURCES BOARD Acknowledgements  

E-Print Network (OSTI)

This report was prepared with the assistance and support from other agencies, divisions and offices of the Air Resources Board, and private firms. Staff would especially like to thank the following individuals for their assistance in developing this proposed pathway:

Green Wastes; Green Wastes; Richard Corey; Deputy Executive Officer; Cynthia Marvin Chief; Michael Waugh Chief; Kamal Ahuja; Brian Helmowski; Wes Ingram; Ray Asregadoo (arb; Juliet Bohn (hwma; Richard Boyd (arb; Alicia Chakrabarthy (ebmud; Steven Cliff (arb; Kevin Dickison (ebmud; Jacques Franco (calrecycle

2012-01-01T23:59:59.000Z

470

Breathing zone air sampler  

DOE Patents (OSTI)

A sampling apparatus is provided which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.

Tobin, John (Bethel Park, PA)

1989-01-01T23:59:59.000Z

471

Retrofitting Air Conditioning and Duct Systems in Hot, Dry Climates  

SciTech Connect

This technical report describes CARB's work with Clark County Community Resources Division in Las Vegas, Nevada, to optimize procedures for upgrading cooling systems on existing homes in the area to implement health, safety, and energy improvements. Detailed monitoring of five AC systems showed that three of the five systems met or exceeded air flow rate goals.

Shapiro, C.; Aldrich, R.; Arena, L.

2012-07-01T23:59:59.000Z

472

Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles  

E-Print Network (OSTI)

Most air handling units (AHUs) in commercial buildings have an air economizer cycle for free cooling under certain outside air conditions. During the economizer cycle, the outside air and return air dampers are modulated to seek mixing air temperature at supply air temperature setpoint. Mechanical cooling is always required when outside air temperature is higher than the supply air temperature setpoint. Generally the supply air temperature setpoint is set at 55°F for space humidity control. Actually the dehumidification is not necessary when outside air dew point is less than 55°F. Meanwhile the space may have less cooling load due to envelope heat loss and/or occupant schedule. These provide an opportunity to use higher supply air temperature to reduce or eliminate mechanical cooling and terminal box reheat. On the other hand the higher supply air temperature will require higher air flow as well as higher fan power. Therefore the supply air temperature has to be optimized to minimize the combined energy for fan, cooling and heating energy. In this paper a simple energy consumption model is established for AHU systems during the economizer and then a optimal supply air temperature control is developed to minimize the total cost of the mechanical cooling and the fan motor power. This paper presents AHU system energy modeling, supply air temperature optimization, and simulated energy savings.

Xu, K.; Liu, M.; Wang, G.; Wang, Z.

2007-01-01T23:59:59.000Z

473

Air Quality | Open Energy Information  

Open Energy Info (EERE)

Air Quality Jump to: navigation, search Retrieved from "http:en.openei.orgwindex.php?titleAirQuality&oldid612070" Category: NEPA Resources...

474

Energy efficiency in military housing: Monitoring to support revitalization guidebook  

Science Conference Proceedings (OSTI)

Oak Ridge National Laboratory is working with the US Army, the US Air Force, and the US Department of Energy to develop a guidebook to be used by architectural and engineering firms in the design phases of military family housing revitalization projects. The purpose of the guidebook is to ensure that energy efficiency is properly addressed in revitalization projects. Monitoring space-heating and cooling energy used in houses both before and after they are revitalized is necessary in order to assess the amount of energy saved by the revitalization process. Three different methods of conducting monitoring experiments are discussed, as well as the methods of data analysis to be used. Houses will be monitored individually using standard gas and electric meters to obtain heating and cooling data for the houses. The authors recommend conducting monitoring programs at Altus Air Force Base, Oklahoma, and Fort Monmouth, New Jersey, because of their project schedules and potential for savings. They do not recommend doing any monitoring at Malmstrom Air Force Base, Montana, because of the relatively small savings that they expect revitalization to accomplish there. They do not recommend seeking out alternative sites for monitoring because of the time required to become familiar with the installation and also because revitalization schedules at alternative sites may be no better than those at the sites they inspected.

Levins, W.P.; Ternes, M.P.

1994-11-01T23:59:59.000Z

475

FREE AIR PRESSURE MEASUREMENTS  

SciTech Connect

Indenter gages, Wiancko gages, and interferometer gages were used to measure air overpressure vs time at essentially ground level stations for both the surface (S) and undprground (U) atomic explosions. For the S Burst several instruments were placed on a line extending from an overpressure region of 13 psi to a region of less than one psi. The air measurements for the U Burst ranged from 32 to 2 psi. (D. L.G.)

Howard, W.J.; Jones, R.D.

1952-02-19T23:59:59.000Z

476

EMERGENCY MANAGEMENT QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emergency Emergency Management Qualification Standard Reference Guide JUNE 2009 Table of Contents i LIST OF FIGURES ...................................................................................................................... ii LIST OF TABLES ........................................................................................................................ ii ACRONYMS .................................................................................................................................. i PURPOSE...................................................................................................................................... 1 SCOPE ...........................................................................................................................................

477

FACILITY MAINTENANCE MANAGEMENT QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Facility Facility Maintenance Management Qualification Standard Reference Guide NOVEMBER 2009 Table of Contents i FIGURES...................................................................................................................................... iv TABLES........................................................................................................................................ iv ACRONYMS ................................................................................................................................. v PURPOSE...................................................................................................................................... 1 SCOPE ...........................................................................................................................................

478

ENVIRONMENTAL COMPLIANCE QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Environmental Environmental Compliance Qualification Standard Reference Guide DECEMBER 2011 Table of Contents i LIST OF FIGURES ..................................................................................................................... iii LIST OF TABLES ....................................................................................................................... iii ACRONYMS ................................................................................................................................ iv PURPOSE ...................................................................................................................................... 1 SCOPE ........................................................................................................................................... 1

479

ENVIRONMENTAL RESTORATION QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Restoration Qualification Standard Reference Guide NOVEMBER 2009 i Table of Contents i FIGURES...................................................................................................................................... iv TABLES........................................................................................................................................ iv ACRONYMS ................................................................................................................................. v PURPOSE...................................................................................................................................... 1 SCOPE ...........................................................................................................................................

480

CRITICALITY SAFETY QUALIFICATION STANDARD REFERENCE GUIDE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Criticality Criticality Safety Qualification Standard Reference Guide APRIL 2011 This page is intentionally blank. Table of Contents i FIGURES ...................................................................................................................................... iii PURPOSE ...................................................................................................................................... 1 SCOPE ........................................................................................................................................... 1 PREFACE ...................................................................................................................................... 1 ACKNOWLEDGEMENTS ......................................................................................................... 2

Note: This page contains sample records for the topic "air monitoring reference" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.