Powered by Deep Web Technologies
Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

E-Print Network 3.0 - air infiltration rates Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Walls: Computational Fluid Dynamics Investigations Results Summary: that conduction heat loss (or gain) through walls is independent of air infiltration heat loss (or gain)....

2

Reduce Air Infiltration in Furnaces  

Broader source: Energy.gov [DOE]

This tip sheet describes how to save process heating energy and costs by reducing air infiltration in industrial furnaces; tips include repairing leaks and increasing insulation.

3

PFT Air Infiltration Measurement Technique | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

PFT Air Infiltration Measurement Technique PFT Air Infiltration Measurement Technique PFT Air Infiltration Measurement Technique April 2, 2012 - 3:11pm Addthis The Brookhaven National Laboratory developed the PFT (PerFluorocarbon tracer gas) technique to measure changes over time when determining a building's air-infiltration rate. The Brookhaven National Laboratory developed the PFT (PerFluorocarbon tracer gas) technique to measure changes over time when determining a building's air-infiltration rate. What does this mean for me? You can save 5%-30% on your energy bill by making upgrades following a home energy assessment. A professional energy auditor may use the PFT air infiltration measurement technique to find out where your home has air leaks, though a blower door test is more commonly used.

4

Energy Crossroads: Ventilation, Infiltration & Indoor Air Quality |  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ventilation, Infiltration & Indoor Air Quality Ventilation, Infiltration & Indoor Air Quality Suggest a Listing Air Infiltration and Ventilation Centre (AIVC) The AIVC fulfills its objectives by providing a range of services and facilities which include: Information, Technical Analysis, Technical Interchange, and Coordination. American Conference of Governmental Industrial Hygienists (ACGIH) The ACGIH offers high quality technical publications and learning opportunities. Americlean Services Corp. (ASC) ASC is a certified SBA 8(a) engineering/consulting firm specializing in HVAC contamination detection, abatement, and monitoring. In addition to highly professional ductwork cleaning and HVAC cleaning services, ASC offers a wide range of other engineering/ consulting/ management services

5

Reduce Air Infiltration in Furnaces (English/Chinese) (Fact Sheet)  

SciTech Connect (OSTI)

Chinese translation of the Reduce Air Infiltration in Furnaces fact sheet. Provides suggestions on how to improve furnace energy efficiency. Fuel-fired furnaces discharge combustion products through a stack or a chimney. Hot furnace gases are less dense and more buoyant than ambient air, so they rise, creating a differential pressure between the top and the bottom of the furnace. This differential, known as thermal head, is the source of a natural draft or negative pressure in furnaces and boilers. A well-designed furnace (or boiler) is built to avoid air leakage into the furnace or leakage of flue gases from the furnace to the ambient. However, with time, most furnaces develop cracks or openings around doors, joints, and hearth seals. These openings (leaks) usually appear small compared with the overall dimensions of the furnace, so they are often ignored. The negative pressure created by the natural draft (or use of an induced-draft fan) in a furnace draws cold air through the openings (leaks) and into the furnace. The cold air becomes heated to the furnace exhaust gas temperature and then exits through the flue system, wasting valuable fuel. It might also cause excessive oxidation of metals or other materials in the furnaces. The heat loss due to cold air leakage resulting from the natural draft can be estimated if you know four major parameters: (1) The furnace or flue gas temperature; (2) The vertical distance H between the opening (leak) and the point where the exhaust gases leave the furnace and its flue system (if the leak is along a vertical surface, H will be an average value); (3) The area of the leak, in square inches; and (4) The amount of operating time the furnace spends at negative pressure. Secondary parameters that affect the amount of air leakage include these: (1) The furnace firing rate; (2) The flue gas velocity through the stack or the stack cross-section area; (3) The burner operating conditions (e.g., excess air, combustion air temperature, and so on). For furnaces or boilers using an induced-draft (ID) fan, the furnace negative pressure depends on the fan performance and frictional losses between the fan inlet and the point of air leakage. In most cases, it would be necessary to measure or estimate negative pressure at the opening. The amount of air leakage, the heat lost in flue gases, and their effects on increased furnace or boiler fuel consumption can be calculated by using the equations and graphs given in Industrial Furnaces (see W. Trinks et al., below). Note that the actual heat input required to compensate for the heat loss in flue gases due to air leakage would be greater than the heat contained in the air leakage because of the effect of available heat in the furnace. For a high-temperature furnace that is not maintained properly, the fuel consumption increase due to air leakage can be as high as 10% of the fuel input.

Not Available

2011-10-01T23:59:59.000Z

6

Infiltration and indoor air quality in a sample of passive-solar and super-insulated houses  

SciTech Connect (OSTI)

Infiltration rates and indoor air quality were measured in 16 solar and super insulated houses in California. In this area careful construction can, at reasonable cost, reduce infiltration to 0.2 to 0.5 air changes per hour (40 to 100 ft/sup 3//min). To evaluate possible indoor air quality problems at these low infiltration rates, levels of three pollutants were monitored in early 1982 during weather cold enough to encourage occupants to keep their windows closed. NO/sub 2/, formaldehyde, and radon were measured using inexpensive, passive monitors. The blower door infiltration measurements are described and relationships between relevant building and occupant characteristics and observed levels of pollutants are discussed. These levels are also compared to current standards; implications for housing design and construction techniques are discussed, and further research needs are suggested.

Wagner, B.S,; Rosenfeld, A.H.

1982-06-01T23:59:59.000Z

7

E-Print Network 3.0 - air infiltration Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Walls: Computational Fluid Dynamics Investigations Results Summary: that conduction heat loss (or gain) through walls is independent of air infiltration heat loss (or gain)....

8

Accumulation and replacement of exchangeable sodium in soils of Southeast Texas under turfgrass and its effect on soil infiltration rate  

E-Print Network [OSTI]

in soils of this area. This study assessed the degree of Na accumulation on cation exchange sites as affected by gypsum treatments in soils that support turfgrass (bermudagrass) and the response of soil infiltration rate to different rates of gypsum...

Aydemir, Salih

2012-06-07T23:59:59.000Z

9

Effect of room air recirculation delay on the decay rate of tracer gas  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Effect of room air recirculation delay on the decay rate of tracer gas Effect of room air recirculation delay on the decay rate of tracer gas concentration Title Effect of room air recirculation delay on the decay rate of tracer gas concentration Publication Type Journal Article Year of Publication 2007 Authors Lorenzetti, David M., Astrid H. Kristoffersen, and Ashok J. Gadgil Journal Indoor Air Pagination 7 Keywords recirculating ventilation, tracer decay rate Abstract Tracer gas measurements are used to estimate the flow rate of fresh air into a room or building. These methods commonly account for the decay of tracer gas concentration as the result of ventilation air supply and infiltration, using a well-mixed model of the space. Some researchers also have considered the effect of leakage in the ventilation ductwork. This paper considers the effect of recirculation through ventilation ducts on the calculated fresh air supply rate. Transport delay in the ducts can significantly alter the time evolution of tracer concentration, and hence alter the estimated air change rate.

10

Ventilating Existing Homes in the US Air Infiltration Review. 2010;31(2)  

E-Print Network [OSTI]

.energy.gov/buildings/building_america/)). In these new homes it was relatively simple to include air retarders in walls, floors or ceilings and to seal this in existing homes, however, presents a significantly tougher challenge. Air sealing has historically (e.g., in US DOE weatherization programs: http://apps1.eere.energy.gov/weatherization/wxtech_air_sealing

11

IMPACT OF REDUCED INFILTRATION AND VENTILATION ON INDOOR AIR QUALITY IN RESIDENTIAL BUILDINGS  

E-Print Network [OSTI]

Critical Analysis of Nitrogen Dioxide Air Quality Standards.contaminants-. ;--- ---- nitrogen dioxide from gas stoves,buildings: nitrogen dioxide (N02), formaldehyde (HCHO), and

Hollowell, Craig D.

2011-01-01T23:59:59.000Z

12

Effect of room air recirculation delay on the decay rate of tracer gas  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Effect of room air recirculation delay on the decay rate of tracer gas Effect of room air recirculation delay on the decay rate of tracer gas Title Effect of room air recirculation delay on the decay rate of tracer gas Publication Type Conference Proceedings Year of Publication 2004 Authors Kristoffersen, Astrid H., Ashok J. Gadgil, and David M. Lorenzetti Conference Name 9th International Conference on Air Distribution in Rooms - RoomVent 2004, Pagination pp 6 Date Published September 5-8, 2 Conference Location Coimbra, Portugal Abstract Tracer gas measurements are commonly used to estimate the fresh air exchange rate in a room or building. Published tracer decay methods account for fresh air supply, infiltration, and leaks in ductwork. However, the time delay associated with a ventilation system recirculating tracer back to the room also affects the decay rate. We present an analytical study of tracer gas decay in a well-mixed, mechanically-ventilated room with recirculation. The analysis shows that failing to account for delays can lead to under- or over-estimates of the fresh air supply, depending on whether the decay rate calculation includes the duct volume

13

An Air-Flow Rate Regulator  

Science Journals Connector (OSTI)

A circuit that automatically maintains a constant airflow rate (1.2 l/min) is described. The device is used in an A3-5 aerosol-particle counter.

V. K. Kovalevskii; E. V. Pokrovskii

2001-03-01T23:59:59.000Z

14

The Measured Energy Impact of Infiltration in an Outdoor Test Cell  

E-Print Network [OSTI]

of these studies quantified energy loss reduction under a variety of outdoor weather conditions. The energy performance was investigated in an outdoor test cell with different leakage configurations and air flow rates under both infiltration and exfiltration...

Liu, M.; Claridge, D. E.

15

CANCELLED: Mechanism of Human Responses to Ventilation Rates and Air  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

CANCELLED: Mechanism of Human Responses to Ventilation Rates and Air CANCELLED: Mechanism of Human Responses to Ventilation Rates and Air Temperature Speaker(s): Henry Willem Date: July 2, 2010 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Max Sherman (THIS SEMINAR TO BE RESCHEDULED.) Sustainability of the built-environment must be achieved in parallel with the sustenance of occupants' health and comfort. Actions to conserve energy and resources require much forethought and careful consideration due to possible consequences on the human aspects. Thus, many extensive works in the recent decades have focused on identifying the associations between indoor environment and human responses. Results have shown moderate to strong implications of thermal and indoor air quality factors on the prevalence and intensity of sick

16

Health Relevant Outdoor Air Change Rates in Homes  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Health Relevant Outdoor Air Change Rates in Homes Health Relevant Outdoor Air Change Rates in Homes Speaker(s): Jan Sundell Date: February 6, 2003 - 12:00pm Location: Bldg. 90 The Damp Building and Health (DBH) study started as a cross-sectional questionnaire study of all 14000 children, 1-6 years of age in Värmland, Sweden. The response rate on the questionnaire (year 2001) was 79%, meaning that basic data exists on almost 12,000 children and their homes. In a second step a case-control study on 200 sick (wheezing, asthma, excema), and 200 healthy children, extensive measurements in the home, as well as clinical examinations of the children has been conducted during 2002. Ventilation has been measured with a passive tracer gas method during one week. The results will be presented in this seminar-- seemingly sick

17

Effect of Outside Air Ventilation Rate on Volatile Organic Compound  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Outside Air Ventilation Rate on Volatile Organic Compound Outside Air Ventilation Rate on Volatile Organic Compound Concentrations in a Call Center Title Effect of Outside Air Ventilation Rate on Volatile Organic Compound Concentrations in a Call Center Publication Type Journal Article Year of Publication 2003 Authors Hodgson, Alfred T., David Faulkner, Douglas P. Sullivan, Dennis L. DiBartolomeo, Marion L. Russell, and William J. Fisk Journal Atmospheric Environment Volume 37 Start Page Chapter Pagination 5517-5528 Abstract A study of the relationship between outside air ventilation rate and concentrations of volatile organic compounds (VOCs) generated indoors was conducted in a call center office building. The building, with two floors and a floor area of 4,600 m2, was located in the San Francisco Bay Area, CA. Ventilation rates were manipulated with the building's four air handling units (AHUs). VOC concentrations in the AHU returns were measured on seven days during a 13-week period. VOC emission factors were determined for individual zones on days when they were operating at near steady-state conditions. The emission factor data were subjected to principal component (PC) analysis to identify groups of co-varying compounds. Potential sources of the PC vectors were ascribed based on information from the literature supporting the associations. Two vectors with high loadings of compounds including formaldehyde, 2,2,4-trimethyl-1,3- pentanediol monoisobutyrate, decamethylcyclopentasiloxane (d5 siloxane), and isoprene likely identified occupant-related sources. One vector likely represented emissions from building materials. Another vector represented emissions of solvents from cleaning products. The relationships between indoor minus outdoor VOC concentrations and ventilation rate were qualitatively examined for eight VOCs. Of these, acetaldehyde and hexanal, which were likely associated with material sources, and d5 siloxane exhibited general trends of higher concentrations at lower ventilation rates. For other compounds, the operation of the building and variations in pollutant generation and removal rates apparently combined to obscure the inverse relationship between VOC concentrations and ventilation. This result emphasizes the importance of utilizing source control measures, in addition to adequate ventilation, to limit concentrations of VOCs of concern in office buildings

18

Relationship between formation water rate, equivalent penetration rate and volume flow rate of air in air drilling  

Science Journals Connector (OSTI)

Formation water invasion is the most troublesome problem associated with air drilling. However, it is not economical to apply mist drilling when only a small amount of water flows into wellbore from formation dur...

Wang Kexiong; Zhang Laibin; Jiang Hongwei

2007-12-01T23:59:59.000Z

19

B-Doped Graphene as Catalyst To Improve Charge Rate of Lithium–Air Battery  

Science Journals Connector (OSTI)

B-Doped Graphene as Catalyst To Improve Charge Rate of Lithium–Air Battery ... The lithium–air battery as an energy storage technology can be used in electric vehicles due to its large energy density, while its poor rate capability limits its practical usage under large current density. ... According to first-principles thermodynamics calculation, we predict B-doped graphene can be a potential catalyst to improve the charge rate of lithium–air battery. ...

Xiaodong Ren; Jinzhen Zhu; Fuming Du; Jianjun Liu; Wenqing Zhang

2014-09-10T23:59:59.000Z

20

Seasonal Variation in Monthly Average Air Change Rates Using Passive Tracer Gas Measurements  

E-Print Network [OSTI]

of indoor air pollution sources. Concurrently, great efforts are made to make buildings energy efficient 1970s, while less attention has been paid to IAQ. Insufficient venting of indoor air pollutantsSeasonal Variation in Monthly Average Air Change Rates Using Passive Tracer Gas Measurements Marie

Hansen, René Rydhof

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Prediction of Room Air Diffusion for Reduced Diffuser Flow Rates  

E-Print Network [OSTI]

modeling at the air supply device (ASHRAE Research Project RP -1009, ?Simplified Diffuser Boundary Conditions for Numerical Room Airflow Models, 2001) 2.2.4 Box model Nielsen (1989, 1992) proposed the box method with an imaginary box near.... Nielsen (1989, 13 1992). Results obtained from the box method are in good agreement with the measured data. Figure 5 Methods for momentum modeling in front of an air supply device (ASHRAE RP -1009, ?Simplified Diffuser Boundary Conditions...

Gangisetti, Kavita

2011-02-22T23:59:59.000Z

22

Effect of outside air ventilation rate on VOC concentrations and emissions  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Effect of outside air ventilation rate on VOC concentrations and emissions Effect of outside air ventilation rate on VOC concentrations and emissions in a call center Title Effect of outside air ventilation rate on VOC concentrations and emissions in a call center Publication Type Conference Proceedings Year of Publication 2002 Authors Hodgson, Alfred T., David Faulkner, Douglas P. Sullivan, Dennis L. DiBartolomeo, Marion L. Russell, and William J. Fisk Conference Name Proceedings of the Indoor Air 2002 Conference, Monterey, CA Volume 2 Pagination 168-173 Publisher Indoor Air 2002, Santa Cruz, CA Abstract A study of the relationship between outside air ventilation rate and concentrations of VOCs generated indoors was conducted in a call center. Ventilation rates were manipulated in the building's four air handling units (AHUs). Concentrations of VOCs in the AHU returns were measured on 7 days during a 13- week period. Indoor minus outdoor concentrations and emission factors were calculated. The emission factor data was subjected to principal component analysis to identify groups of co-varying compounds based on source type. One vector represented emissions of solvents from cleaning products. Another vector identified occupant sources. Direct relationships between ventilation rate and concentrations were not observed for most of the abundant VOCs. This result emphasizes the importance of source control measures for limiting VOC concentrations in buildings

23

Dynamic Control of Lab Air Change Rates using Multiplexed IEQ Monitoring  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Dynamic Control of Lab Air Change Rates using Multiplexed IEQ Monitoring Dynamic Control of Lab Air Change Rates using Multiplexed IEQ Monitoring Speaker(s): Gordon P. Sharp Date: October 14, 2005 - 12:00pm Location: Bldg. 90 Many aspects of a lab are monitored today in real time such as HVAC equipment operation and lab airflow quantities. However, the quality of lab room airflow or more specifically, the indoor environmental quality (IEQ) performance of a lab, beyond just temperature or perhaps humidity, is rarely monitored due to sensor cost and calibration issues. This is unfortunate, since detailed IEQ monitoring data can be used to substantially reduce lab energy consumption, increase lab safety and with some additional analysis, this data can be used to perform effective continuous commissioning. This presentation discusses a new type of real

24

Effects of airflow infiltration on the thermal performance of internally  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Effects of airflow infiltration on the thermal performance of internally Effects of airflow infiltration on the thermal performance of internally insulated ducts Title Effects of airflow infiltration on the thermal performance of internally insulated ducts Publication Type Journal Article Year of Publication 2000 Authors Levinson, Ronnen M., William W. Delp, Darryl J. Dickerhoff, and Mark P. Modera Journal Energy and Buildings Volume 32 Pagination 345-354 Keywords building design, Heat Island Abstract Air flowing through a supply duct infiltrates perviously faced, porous, internal duct insulation, degrading its thermal performance. Encapsulating the insulation's air-facing surface with an impervious barrier prevents infiltration, increasing the capacity of the conditioned supply air to heat or cool the space to which it is delivered. This study determined the air-speed dependence of the thermal conductivity of fiberglass insulation by measuring the inlet-to-outlet temperature drop of heated air flowing through a long, insulated flexible duct. The conductivity of a flexible duct's low-density, internal, fiberglass-blanket insulation increased with the square of the duct air speed, rising by 140% as the duct air speed increased from 0 to 15 m s-1. At air speeds recommended for branch ducts, the conductivity of such insulation would increase by 6% above its still-air value in a residential system and by 16% in a commercial system. Results partially agreed with those reported by an earlier study. Simulations indicate that encapsulating the air-stream surface of internal fiberglass duct insulation with an impervious barrier increases the effectiveness with which a duct delivers the thermal capacity of supply air by 0.15%-0.9% in typical duct systems.

25

High-rate HMDSO-based coatings in open air using atmospheric-pressure plasma jet  

Science Journals Connector (OSTI)

This work deals with the high-rate and dust-free formation of carbon-containing silicon oxide (SiOC) coatings in open air without substrate heating using an atmospheric-pressure (AP) plasma jet. The AP plasma was excited by a 13.56-MHz radio frequency (RF) power. Hexamethyldisiloxane and oxygen (O2) were used as the source gases. By optimizing the O2 flow rate and RF power, SiOC films were readily fabricated at deposition rates higher than 100 nm/s without suffering from particulate contaminations of the film surface. Additionally, an inorganic SiO2-like film exhibiting O/Si atomic ratio of approximately 2 was obtained at a deposition rate of ~ 13 nm/s, the value of which is still greater than those obtained in other AP plasma sources. Further systematic studies are needed to see if good-quality inorganic SiO2-like films can be obtained with higher rates.

H. Kakiuchi; K. Higashida; T. Shibata; H. Ohmi; T. Yamada; K. Yasutake

2012-01-01T23:59:59.000Z

26

INDOOR AIR QUALITY AND ENERGY EFFICIENT VENTILATION RATES AT A NEW YORK CITY ELEMENTARY SCHOOL  

E-Print Network [OSTI]

UC-95d INDOOR AIR QUALITY AND ENERGY EFFICIENT VENTILATIONVentilation on Indoor Air Quality and Energy Use in Schoo s,EEB~Vent INDOOR AIR QUALITY AND ENERGY EFFICIENT VENTILATION

Young, Rodger A.

2013-01-01T23:59:59.000Z

27

A review of fatigue crack growth rates for offshore steels in air and seawater environments  

SciTech Connect (OSTI)

A literature review of fatigue crack growth rates (FCGR) has been performed for steels in air and seawater environments, either free corroding or with applied cathodic protection potentials of {minus}850 and {minus}1050/{minus}1100 mV Ag/AgCl. In all cases a more precise description of cracking was obtained using a bi-linear growth law rather than the more conventional Paris Law. Recommendations were made for mean and design values of the constants C and m on a piece-wise basis suitable for use in fracture mechanics analyses of structures. An effect of R-ratio was observed, and separate recommendations were made for high and low R-ratios to cater for as-welded, and post weld heat treated joints with low mean stress levels.

King, R.N. [Failure Control Ltd., Cranleigh (United Kingdom); Stacey, A.; Sharp, J.V. [Health and Safety Executive, London (United Kingdom). Offshore Safety Div.

1996-12-01T23:59:59.000Z

28

CO2 tracer gas concentration decay method for measuring air change rate  

Science Journals Connector (OSTI)

Abstract The measure of air change rate (ACR) in building is a difficult and usually expensive task. The tracer gas method is the reference technique but its implementation is difficult and the interpretation of results is not straightforward. In the present work, the concentration decay method by multiple CO2 transmitters is experimentally validated in the case of cross-ventilation. It is observed that in-situ CO2 transmitters lead to ACR values in good agreement with reference measurements obtained from mechanically controlled values. Whereas multiple transmitters in different sampling positions show the imperfect mixing, a sensor located at the outlet or an averaged value of all sensors can provide an accurate measure of the ACR. Moreover, the spatial variation of CO2 concentration can be used to assess the ventilation efficiency in the test chamber. Different measures and calculation methods are discussed, and the uncertainty analysis of each method is carried out.

Shuqing Cui; Michaël Cohen; Pascal Stabat; Dominique Marchio

2015-01-01T23:59:59.000Z

29

AIR-EARTH INTERFACE MODEL FOR RESTORING RIPARIAN HABITATS1 Robert M . Dixon2  

E-Print Network [OSTI]

(AEI) Model involves four interrelated and interacting AEI processes--desertification, infiltration denudes, smooths, and seals the air-earth interface to inhibit infiltration and revegetation processes

Standiford, Richard B.

30

A prediction of energy savings resulting from building infiltration control  

E-Print Network [OSTI]

, temperature ('C) Indoor, or room, temperature of building ('C) Temperature of exterior surface of a building wall, window or roof ( C) Sol-air temperature for a wall or other building surface ('C) Interchangeable with T, Difference between building room... infiltration Designating airflow into a building surface Maximum model Minimum Interaction heat transfer calculation model N North Pressure Surface South sa Sol-air Room tot Total CHAPTER I INTRODUCTION 1. 1 OBJECTIVES Heating and cooling...

McWatters, Kenneth Rob

1995-01-01T23:59:59.000Z

31

The air dose rate around the Fukushima Dai-ichi Nuclear Power Plant: its spatial characteristics and temporal changes until December 2012  

Science Journals Connector (OSTI)

Abstract Distribution maps of air dose rates around the Fukushima Dai-ichi Nuclear Power Plant were constructed using the results of measurement obtained from approximately 6500 locations (at most) per measurement period. The measurements were conducted 1 m above the ground using survey meters in flat and spatially open locations. Spatial distribution and temporal change of the air dose rate in the area were revealed by examining the resultant distribution maps. The observed reduction rate of the air dose rate over the 18 months between June 2011 and December 2012 was greater than that calculated from radioactive decay of radiocesium by 10% in relative percentage except decontaminated sites. This 10% difference in the reduction of the air dose rate can be explained by the mobility of radiocesium in the depth direction. In the region where the air dose rate was lower than 0.25 ?Sv h?1 on June 2011, the reduction of the air dose rate was observed to be smaller than that of the other dose rate regions, and it was in fact smaller than the reduction rate caused by radioactive decay alone. In contrast, the reduction rate was larger in regions with higher air dose rates. In flat and spatially open locations, no significant difference in the reduction tendency of air dose rates was observed among different land use classifications (rice fields, farmland, forests, and building sites).

Satoshi Mikami; Takeshi Maeyama; Yoshifumi Hoshide; Ryuichi Sakamoto; Shoji Sato; Naotoshi Okuda; Tetsuro Sato; Hiroshi Takemiya; Kimiaki Saito

2014-01-01T23:59:59.000Z

32

Effects of Sounds From Seismic Air Guns on Fish Behavior and Catch Rates  

Science Journals Connector (OSTI)

Seismic surveys are performed to explore for oil ... Concerns have been raised about the impacts of seismic air gun emissions on marine life, and fishermen in particular claim that seismic surveys have a serious ...

Svein Løkkeborg; Egil Ona; Aud Vold; Are Salthaug

2012-01-01T23:59:59.000Z

33

VOL. II, NO.6 WATER RESOURCES RESEARCH DECEMBER 1975 Factors Influencing Infiltration and Sediment Production of  

E-Print Network [OSTI]

VOL. II, NO.6 WATER RESOURCES RESEARCH DECEMBER 1975 Factors Influencing Infiltration and Sediment. College Station. Texas 77843 Simulated rainfall was used to study infiltration rates and sedimentIOn rates and sediment production of the various soils are largely controlled by extent and surface

Ahmad, Sajjad

34

Nanosecond discharge in air at atmospheric pressure as an x-ray source with high pulse repetition rates  

SciTech Connect (OSTI)

The properties of x-ray radiation and runaway electrons produced using a nanosecond volume discharge are examined. X-ray radiation at a pulse repetition rate of 3 kHz was obtained time in a gas diode filled with air at atmospheric pressure. The current pulse width (FWHM) for runaway electrons generated in the gas diode was {approx}100 ps. A prepulse was observed on an oscilloscope trace of the main runaway electron beam current.

Tarasenko, Victor F. [Institute of High Current Electronics, Siberian Branch of the Russian Academy of Sciences, Tomsk 634021, pr. Akademicheskii 2/3 (Russian Federation)

2006-02-20T23:59:59.000Z

35

Predicting Residential Air Exchange Rates from Questionnaires and Meteorology: Model Evaluation in Central North Carolina  

Science Journals Connector (OSTI)

The capability of the LBL, LBLX, and SF models could help reduce the AER uncertainty in air pollution exposure models used to develop exposure metrics for health studies. ... The parameters for the low-income homes were estimated using measurements from the Ohio Weatherization Program, which included residences with household incomes below 125% of the poverty guideline (14). ...

Michael S. Breen; Miyuki Breen; Ronald W. Williams; Bradley D. Schultz

2010-11-11T23:59:59.000Z

36

Rainwater Harvesting: Soil Storage and Infiltration System  

E-Print Network [OSTI]

A soil storage and infiltration system collects rainfall runoff from the roofs of buildings and directs it underground where it infiltrates the soil. Such a system conserves water and protects it from surface pollution. This publication describes...

Mechell, Justin; Lesikar, Bruce J.

2008-08-11T23:59:59.000Z

37

Acoustic Building Infiltration Measurement System (ABIMS)  

Broader source: Energy.gov [DOE]

The Acoustic Building Infilitration Measurement System project is developing an acoustic method of measuring the infiltration of a building envelope.

38

The effect of an enclosure retrofit on air leakage rates for a multi-unit residential case-study building  

Science Journals Connector (OSTI)

Abstract This paper presents a relatively new, simple and robust, method for air leakage testing. A thirteen-story multi-unit residential building was tested for air leakage before and after an enclosure retrofit. The building suites had a pre-retrofit NLA50 average of 6.77 cm2/m2 and an average post-retrofit NLA50 of 2.82 cm2/m2—a 58% betterment. The effect of the retrofit on air leakage rates was assessed and compared to other multi-unit residential buildings across Canada and USA. The case study building was significantly tighter than other multi-unit residential buildings included in published studies. Recommendations were made for field-testing procedures in order to maximize the potential for accurate measured flow characteristics. Field-testing for air-tightness needs to be standardized in order for useful comparative results to be generated in order to inform future research and operational considerations for the multi-unit residential building stock across North America.

Robin Urquhart; Russell Richman; Graham Finch

2015-01-01T23:59:59.000Z

39

MEMOIRS OF A LEAK: Infiltrating Research for a Quarter of a Century  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

MEMOIRS OF A LEAK: Infiltrating Research for a Quarter of a Century MEMOIRS OF A LEAK: Infiltrating Research for a Quarter of a Century Speaker(s): Max Sherman Date: November 16, 2000 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: David Faulkner Infiltration is the (usually uncontrolled) flow of air through leaks in the building envelope, driven by natural and mechanical pressures. Before the oil crises, there was not a lot of interest in infiltration. For houses and other envelope-dominated buildings, however, infiltration typically accounted for all of their ventilation needs and 1/3-1/2 of their space-conditioning load. Starting in the mid-70s there was a realization that this important problem was not well understood, but represented an important energy-saving opportunity. Research institutions around the world

40

Corrosion product identification and relative rates of corrosion of candidate metals in an irradiated air-steam environment  

SciTech Connect (OSTI)

Previously reported work by others indicates that dicopper trihydroxide nitrate, Cu{sub 2}NO{sub 3}(OH){sub 3}, forms on copper and copper alloys subjected to irradiated moist air near room temperature. We have performed experiments over a range of temperature and humidity, and have found that this species is formed at temperatures up to at least 150{degree}C if low to intermediate relative humidities are present. At 150{degree}C and 100% relative humidity, only Cu{sub 2}O and CuO were observed. The relative general corrosion rates of the copper materials tested in 1-month experiments at dose rates of 0.7 and 2.0 kGy/h were Cu > 70/30 Cu--Ni > Al-bronze. High-nickel alloy 825 showed no observable corrosion. 29 refs., 4 tabs.

Reed, D.T.; Swayambunathan, V.; Tani, B.S. (Argonne National Lab., IL (USA)); Van Konynenburg, R.A. (Lawrence Livermore National Lab., CA (USA))

1989-11-03T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Infiltration Effects on Residential Pollutant Concentrations for Continuous  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Infiltration Effects on Residential Pollutant Concentrations for Continuous Infiltration Effects on Residential Pollutant Concentrations for Continuous and Intermittent Mechanical Ventilation Approaches Title Infiltration Effects on Residential Pollutant Concentrations for Continuous and Intermittent Mechanical Ventilation Approaches Publication Type Journal Article LBNL Report Number LBNL-3978E Year of Publication 2011 Authors Sherman, Max H., Jennifer M. Logue, and Brett C. Singer Journal HVAC&R Research Volume 17 Issue 2 Pagination 159 Publisher Lawrence Berkeley National Laboratory Keywords resave Abstract The prevailing residential ventilation standard in North America, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 62.2, specifies volumetric airflow requirements as a function of the overall size of the home and the number of bedrooms, assumes a fixed, minimal amount of infiltration, and requires mechanical ventilation to achieve the remainder. The standard allows for infiltration credits and intermittent ventilation patterns that can be shown to provide comparable performance. Whole-house ventilation methods have a substantial effect on time-varying indoor pollutant concentrations. If alternatives specified by Standard 62.2, such as intermittent ventilation, are used, short-term pollutant concentrations could exceed acute health standards even if chronic health standards are met.The authors present a methodology for comparing ASHRAE- and non-ASHRAE-specified ventilation scenarios on relative indoor pollutant concentrations. We use numerical modeling to compare the maximum time-averaged concentrations for acute exposure relevant (1-hour, 8-hour, 24-hour ) and chronic exposure relevant (1-year) time periods for four different ventilation scenarios in six climates with a range of normalized leakage values. The results suggest that long-term concentrations are the most important metric for assessing the effectiveness of whole-house ventilation systems in meeting exposure standards and that, if chronic health exposure standards are met, acute standards will also be met.

42

INFILTRATION MEASUREMENTS IN AUDIT AND RETROFIT PROGRAMS  

E-Print Network [OSTI]

Energy Agency (IEA) Energy Audit Workshop, Elsinore,13-15, 1981. (IEA) Energy Audit INFILTRATION MEASUREMENTS INThe first is an energy audit to determine economically

Grimsrud, D.T.

2014-01-01T23:59:59.000Z

43

RATES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Planning & Projects Planning & Projects Power Marketing Rates You are here: SN Home page > Power Marketing > RATES Rates and Repayment Services Rates Current Rates Power Revenue Requirement Worksheet (FY 2014) (Oct 2013 - Sep 2014) (PDF - 30K) PRR Notification Letter (Sep 27, 2013) (PDF - 959K) FY 2012 FP% True-Up Calculations(PDF - 387K) Variable Resource Scheduling Charge FY12-FY16 (October 1, 2012) PRR Forecast FY14-FY17 (May 23, 2013) (PDF - 100K) Forecasted Transmission Rates (May 2013) (PDF - 164K) Past Rates 2013 2012 2011 2010 2009 Historical CVP Transmission Rates (April 2013) (PDF - 287K) Rate Schedules Power - CV-F13 - CPP-2 Transmission - CV-T3 - CV-NWT5 - PACI-T3 - COTP-T3 - CV-TPT7 - CV-UUP1 Ancillary - CV-RFS4 - CV-SPR4 - CV-SUR4 - CV-EID4 - CV-GID1 Federal Register Notices - CVP, COTP and PACI

44

RATES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Marketing > RATES Marketing > RATES RATES Current Rates Past Rates 2006 2007 2008 2009 2010 2011 2012 Rates Schedules Power CV-F13 CPP-2 Transmissions CV-T3 CV-NWT5 PACI-T3 COTP-T3 CV-TPT7 CV-UUP1 Ancillary CV-RFS4 CV-SPR4 CV-SUR4 CV-EID4 CV-GID1 Future and Other Rates SNR Variable Resource Scheduling Charge FY12-FY16 (October 1, 2012) SNR Rates Process Calendar (PDF - 171K) Procedures Informal Process Transmission Action Items List (PDF - 144K) Power Action Item List updated on 4-27-10 (PDF - 155K) Power Action Item List (Quick links to relevant documents) Formal Process Rates Brochure (01/11/2011) (PDF - 900K) Appendix A - Federal Register Notice (01/03/2011) (PDF - 8000K) Appendix B - Central Valley Project Power Repayment Study (PDF - 22,322K) Appendix C - Development of the CVP Cost of Service Study (PDF - 2038K)

45

Recessed light fixtures: Infiltration energy loss  

SciTech Connect (OSTI)

This article reports that a recent study revealed that fluorescent bulbs can reduce convective energy losses by 15--65% as compared to incandescent bulbs. Recessed light fixtures are commonly installed in offices and homes. However, a problem arises in homes when the fixtures are set in the ceiling such that the top of the light fixture is exposed to the unconditioned air in the attic. Because some air flow is necessary around the light to avoid overheating, the manufacturers do not make all the fixtures leak tight, only those that are rated for lower wattage bulbs. The need for cooling the fixture may conflict with some building efficiency codes.

Bennett, S.M.; Perez-Blanco, H. (Pennsylvania State Univ., University Park, PA (United States))

1994-06-01T23:59:59.000Z

46

The effect of various cropping systems upon the stability of aggregates: the rate of water infiltration, and the organic matter content of three soil conditions in the Texas Blacklands.  

E-Print Network [OSTI]

for 50 years had more than 75 percent oi' its mass made up of soil granules tbs siss of grains of sand and bits of clay" ~ These small soil granules ars not resistant to the impact of rainfall and vhsn they break dovn? both vater and air lanes... the averages are baseg Tabes 2, Analysis of mricnncs of stable a~tea 0, 20 ssc snd larger in the ccnrfoee her of soil, Rsanirsd ~ of Saene of ccsriatien frasdon Sea of ~s Haan ayah toeni, 01, 05 6 090 35 124e0$085 5o6cc. 3a33 Corot sorn lsgnss ~i oem...

Quintero, Angel H

1951-01-01T23:59:59.000Z

47

RATES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

RATES RATES Rates Document Library SNR Rates Process Calendar (PDF - 171K) Procedures Informal Process Transmission Action Items List (PDF - 144K) Power Action Item List updated on 4-27-10 (PDF - 155K) Power Action Item List (Quick links to relevant documents) Formal Process Rates Brochure (01/11/2011) (PDF - 900K) Appendix A - Federal Register Notice (01/03/2011) (PDF - 8000K) Appendix B - Central Valley Project Power Repayment Study (PDF - 22,322K) Appendix C - Development of the CVP Cost of Service Study (PDF - 2038K) Appendix D - Western Transmission System Facilities Map (PDF - 274K) Appendix E - Estimated FY12 FP and BR Customer (PDF - 1144K) Appendix F - Forecasted Replacements and Additions FY11 - FY16 (PDF - 491K) Appendix G - Definitions (PDF - 1758K) Appendix H - Acronyms (PDF - 720K)

48

Particulate air pollution, ambulatory heart rate variability, and cardiac arrhythmia in retirement community residents with coronary artery disease.  

E-Print Network [OSTI]

air pollution in patients with coronary artery disease. Environ Healthair pollution on cardiac arrhythmia: the APACR Study. Environ Healthair pollution and air temperature among myocardial infarction survivors. Environ Health

Bartell, Scott M; Longhurst, John; Tjoa, Thomas; Sioutas, Constantinos; Delfino, Ralph J

2013-01-01T23:59:59.000Z

49

ANEMOS: A computer code to estimate air concentrations and ground deposition rates for atmospheric nuclides emitted from multiple operating sources  

SciTech Connect (OSTI)

This code estimates concentrations in air and ground deposition rates for Atmospheric Nuclides Emitted from Multiple Operating Sources. ANEMOS is one component of an integrated Computerized Radiological Risk Investigation System (CRRIS) developed for the US Environmental Protection Agency (EPA) for use in performing radiological assessments and in developing radiation standards. The concentrations and deposition rates calculated by ANEMOS are used in subsequent portions of the CRRIS for estimating doses and risks to man. The calculations made in ANEMOS are based on the use of a straight-line Gaussian plume atmospheric dispersion model with both dry and wet deposition parameter options. The code will accommodate a ground-level or elevated point and area source or windblown source. Adjustments may be made during the calculations for surface roughness, building wake effects, terrain height, wind speed at the height of release, the variation in plume rise as a function of downwind distance, and the in-growth and decay of daughter products in the plume as it travels downwind. ANEMOS can also accommodate multiple particle sizes and clearance classes, and it may be used to calculate the dose from a finite plume of gamma-ray-emitting radionuclides passing overhead. The output of this code is presented for 16 sectors of a circular grid. ANEMOS can calculate both the sector-average concentrations and deposition rates at a given set of downwind distances in each sector and the average of these quantities over an area within each sector bounded by two successive downwind distances. ANEMOS is designed to be used primarily for continuous, long-term radionuclide releases. This report describes the models used in the code, their computer implementation, the uncertainty associated with their use, and the use of ANEMOS in conjunction with other codes in the CRRIS. A listing of the code is included in Appendix C.

Miller, C.W.; Sjoreen, A.L.; Begovich, C.L.; Hermann, O.W.

1986-11-01T23:59:59.000Z

50

Aerogel composites using chemical vapor infiltration  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Aerogel composites using chemical vapor infiltration Aerogel composites using chemical vapor infiltration Title Aerogel composites using chemical vapor infiltration Publication Type Journal Article Year of Publication 1995 Authors Hunt, Arlon J., Michael R. Ayers, and Wanqing Cao Journal Journal of Non-Crystalline Solids Volume 185 Pagination 227-232 Abstract A new method to produce novel composite materials based on the use of aerogels as a starting material is described. Using chemical vapor infiltration, a variety of solid materials were thermally deposited into the open pore structure of aerogel. The resulting materials possess new and unusual properties including photoluminescence, magnetism and altered optical properties. An important characteristic of this preparation process is the very small size of the deposits that gives rise to new behaviors. Silicon deposits exhibit photoluminescence, indicating quantum confinement. Two or more phases may be deposited simultaneously and one or both chemically or thermally reacted to produce new structures.

51

Summer Infiltration/Ventilation Test Results from the FRTF Laboratory...  

Broader source: Energy.gov (indexed) [DOE]

Summer InfiltrationVentilation Test Results from the FRTF Laboratory Summer InfiltrationVentilation Test Results from the FRTF Laboratory This presentation was delivered at the...

52

AN INTERCOMPARISON OF TRACER GASES USED FOR AIR INFILTRATION MEASUREMENTS  

E-Print Network [OSTI]

Janssen, A.N. Pearman, Honeywell, Inc. , Minneapolis, MN,gas. TABLE Z Research Group Honeywell Princeton LBL LBL LBL

Grimsrud, D.T.

2011-01-01T23:59:59.000Z

53

Analysis Method for Nitrogen Dioxide Rapid Air Monitor Uptake rate (ml/min)= 0.5102 x temp (C) + 18.697  

E-Print Network [OSTI]

Analysis Method for Nitrogen Dioxide Rapid Air Monitor Uptake rate (ml/min)= 0.5102 x temp (°C of the atmospheric concentration of Nitrogen Dioxide using the mass of nitrite on the sampler is made as follows: 6s3

Short, Daniel

54

Measurements of Ice Crystal Growth Rates in Air at -5C and -10C K. G. Libbrecht and H. M. Arnold  

E-Print Network [OSTI]

Measurements of Ice Crystal Growth Rates in Air at -5C and -10C K. G. Libbrecht and H. M. Arnold to: kgl@caltech.edu Abstract. We present experiments investigating the growth of ice crystals from produce large morphological changes at all scales. One popular example of this phenomenon is the formation

Libbrecht, Kenneth G.

55

Effect of air flow rate and fuel moisture on the burning behaviours of biomass and simulated municipal solid wastes in packed beds  

Science Journals Connector (OSTI)

Combustion of biomass and municipal solid wastes is one of the key areas in the global cleaner energy strategy. But there is still a lack of detailed and systematically theoretical study on the packed bed burning of biomass and municipal solid wastes. The advantage of theoretical study lies in its ability to reveal features of the detailed structure of the burning process inside a solid bed, such as reaction zone thickness, combustion staging, rates of individual sub-processes, gas emission and char burning characteristics. These characteristics are hard to measure by conventional experimental techniques. In this paper, mathematical simulations as well as experiments have been carried out for the combustion of wood chips and the incineration of simulated municipal solid wastes in a bench-top stationary bed and the effects of primary air flow rate and moisture level in the fuel have been assessed over wide ranges. It is found that volatile release as well as char burning intensifies with an increase in the primary air flow until a critical point is reached where a further increase in the primary air results in slowing down of the combustion process; a higher primary airflow also reduces the char fraction burned in the final char-burning-only stage, shifts combustion in the bed to a more fuel-lean environment and reduces CO emission at the bed top; an increase in the moisture level in the fuel produces a higher flame front temperature in the bed at low primary air flow rates.

Y.B Yang; V.N Sharifi; J Swithenbank

2004-01-01T23:59:59.000Z

56

Building America Technology Solutions for New and Existing Homes: Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate  

Broader source: Energy.gov [DOE]

This project investigates the impact of air infiltration and ventilation on space cooling and moisture in residential buildings; research was conducted in two identical laboratory homes in the hot-humid climate over the cooling season.

57

Infiltration in ASHRAE's Residential Ventilation Standards  

E-Print Network [OSTI]

of both indoor air quality and energy.   References  ASHRAE both indoor air quality and building energy consumption.  acceptable indoor air quality at minimum energy cost, it is

Sherman, Max

2008-01-01T23:59:59.000Z

58

Role of osteopontin in hepatic neutrophil infiltration during alcoholic steatohepatitis  

SciTech Connect (OSTI)

Alcoholic liver disease (ALD) is a major complication of heavy alcohol (EtOH) drinking and is characterized by three progressive stages of pathology: steatosis, steatohepatitis, and fibrosis/cirrhosis. Alcoholic steatosis (AS) is the initial stage of ALD and consists of fat accumulation in the liver accompanied by minimal liver injury. AS is known to render the hepatocytes increasingly sensitive to toxicants such as bacterial endotoxin (LPS). Alcoholic steatohepatitis (ASH), the second and rate-limiting step in the progression of ALD, is characterized by hepatic fat accumulation, neutrophil infiltration, and neutrophil-mediated parenchymal injury. However, the pathogenesis of ASH is poorly defined. It has been theorized that the pathogenesis of ASH involves interaction of increased circulating levels of LPS with hepatocytes being rendered highly sensitive to LPS due to heavy EtOH consumption. We hypothesize that osteopontin (OPN), a matricellular protein (MCP), plays an important role in the hepatic neutrophil recruitment due to its enhanced expression during the early phase of ALD (AS and ASH). To study the role of OPN in the pathogenesis of ASH, we induced AS in male Sprague-Dawley rats by feeding EtOH-containing Lieber-DeCarli liquid diet for 6 weeks. AS rats experienced extensive fat accumulation and minimal liver injury. Moderate induction in OPN was observed in AS group. ASH was induced by feeding male Sprague-Dawley rats EtOH-containing Lieber-DeCarli liquid diet for 6 weeks followed by LPS injection. The ASH rats had substantial neutrophil infiltration, coagulative oncotic necrosis, and developed higher liver injury. Significant increases in the hepatic and circulating levels of OPN was observed in the ASH rats. Higher levels of the active, thrombin-cleaved form of OPN in the liver in ASH group correlated remarkably with hepatic neutrophil infiltration. Finally, correlative studies between OPN and hepatic neutrophil infiltration was corroborated in a simple rat peritoneal model where enhanced peritoneal fluid neutrophil infiltration was noted in rats injected OPN intraperitoneally. Taken together these data indicate that OPN expression induced during ASH may play a significant role in the pathogenesis of ASH by stimulating neutrophil transmigration.

Apte, Udayan M. [Department of Pathobiology, College of Veterinary Medicine, Texas A and M University, MS4467, College Station, TX 77843-4467 (United States); Banerjee, Atrayee [Department of Pathobiology, College of Veterinary Medicine, Texas A and M University, MS4467, College Station, TX 77843-4467 (United States); McRee, Rachel [Department of Pathobiology, College of Veterinary Medicine, Texas A and M University, MS4467, College Station, TX 77843-4467 (United States); Wellberg, Elizabeth [Department of Pathobiology, College of Veterinary Medicine, Texas A and M University, MS4467, College Station, TX 77843-4467 (United States); Ramaiah, Shashi K. [Department of Pathobiology, College of Veterinary Medicine, Texas A and M University, MS4467, College Station, TX 77843-4467 (United States)]. E-mail: sramaiah@cvm.tamu.edu

2005-08-22T23:59:59.000Z

59

Sensor for Individual Burner Control of Coal Firing Rate, Fuel-Air Ratio and Coal Fineness Correlation  

SciTech Connect (OSTI)

Accurate, cost-efficient monitoring instrumentation has long been considered essential to the operation of power plants. Nonetheless, for the monitoring of coal flow, such instrumentation has been sorely lacking and technically difficult to achieve. With more than half of the electrical power in the United States currently supplied by coal, energy generated by this resource is critical to the US economy. The demand for improvement in this area has only increased as a result of the following two situations: First, deregulation has produced a heightened demand for both reduced electrical cost and improved grid connectivity. Second, environmental concerns have simultaneously resulted in a need for both increased efficiency and reduced carbon and NOx emissions. A potential approach to addressing both these needs would be improvement in the area of combustion control. This would result in a better heat rate, reduced unburned carbon in ash, and reduced NOx emissions. However, before feedback control can be implemented, the ability to monitor coal flow to the burners in real-time must be established. While there are several ''commercially available'' products for real-time coal flow measurement, power plant personnel are highly skeptical about the accuracy and longevity of these systems in their current state of development. In fact, following several demonstration projects of in-situ coal flow measurement systems in full scale utility boilers, it became obvious that there were still many unknown influences on these instruments during field applications. Due to the operational environment of the power plant, it has been difficult if not impossible to sort out what parameters could be influencing the various probe technologies. Additionally, it has been recognized for some time that little is known regarding the performance of coal flow splitters, even where rifflers are employed. Often the coal flow distribution from these splitters remains mal-distributed. There have been mixed results in the field using variable orifices in coal pipes. Development of other coal flow control devices has been limited. An underlying difficulty that, to date, has hindered the development of an accurate instrument for coal flow measurements is the fact that coal flow is characterized by irregular temporal and spatial variation. However, despite the inherent complexity of the dynamic system, the system is in fact deterministic. Therefore, in principle, the coal flow can be deduced from the dynamics it exhibits. Nonetheless, the interactions are highly nonlinear, rendering standard signal processing approaches, which rely on techniques such as frequency decomposition, to be of little value. Foster-Miller, Inc. has developed a methodology that relates the complex variation in such systems to the information of interest. This technology will be described in detail in Section 2. A second concern regarding the current measurement systems is installation, which can be labor-intensive and cost-prohibitive. A process that does not require the pulverizer to be taken off line would be highly desirable. Most microwave and electrostatic methods require drilling up to 20 holes in the pipe, all with a high degree of precision so as to produce a proper alignment of the probes. At least one electrostatic method requires a special spool piece to be fitted into each existing coal pipe. Overall, these procedures are both difficult and very expensive. An alternative approach is pursued here, namely the development of an instrument that relies on an acoustic signal captured by way of a commercial accelerometer. The installation of this type of sensor is both simpler and less invasive than other techniques. An accelerometer installed in a pipe wall need not penetrate through the wall, which means that the system may be able to remain on line during the installation. Further, due to the fact that the Dynamical Instruments technology, unlike other systems, does not rely on uniformity of the air or coal profile, the installation location need not be on a long, straight run

R. Demler

2006-04-01T23:59:59.000Z

60

Traffic-related air pollution exposures and changes in heart rate variability in Mexico City: A panel study  

E-Print Network [OSTI]

carbon monoxide (CO), nitrogen dioxide (NO 2 ), nitrogeninfrared; NO 2 : Nitrogen dioxide; NO x : Nitrogen oxides; OLack of effect of nitrogen dioxide exposure on heart rate

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Window annual energy rating systems: What they tell us about residential window design and selection  

SciTech Connect (OSTI)

Residential window annual energy rating systems have been developed in Canada and the US. These systems combine window properties of solar heat gain coefficient, U-factor, and air-infiltration into a single number representative of the energy performance for each of the heating season and the cooling season. These systems provide a simple means for designers to select the best energy performing window for low-rise residential buildings over the heating and cooling seasons. The two systems, which rank windows in the same order, give different information on optimum window design and selection than just a simple U-factor comparison. These systems show the importance of a high window SHGC in cold climates and a low SHGC in hot climates. The impact of window air infiltration is surprisingly small relative to the solar heat gain and heat conduction losses.

Carpenter, S.C.; McGowan, A.G.; Miller, S.R. [Enermodal Engineering Ltd., Kitchener, Ontario (Canada)

1998-12-31T23:59:59.000Z

62

Winter Infiltration Results from the FRTF Laboratory  

Broader source: Energy.gov (indexed) [DOE]

Florida Florida Winter Infiltration Results from the FRTF Laboratory Building America Stakeholders Meeting Austin, TX March 1-2, 2012 Philip Fairey FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida Project Objectives Under side-by-side, in situ controlled conditions: * Measure effectiveness of various energy retrofit improvements * Produce high-quality empirical data set useful for home energy simulation verification. FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida * Two identical side-by-side 1536 ft 2 , concrete block, slab-on-grade residences * Single pane fenestration, evenly distributed * No concrete block wall insulation

63

Air Pollution  

Science Journals Connector (OSTI)

Both natural processes and human activities contribute to air pollution, with the combustion of fossil fuels being the largest anthropogenic source of air pollutants. Adverse health effects (above all respiratory and cardiovascular complications), damage to crops, natural vegetation and materials, reduced visibility and changed radiation balance of the atmosphere are the major consequences of high concentrations of air pollutants. Technical fixes can sharply reduce emissions from large stationary sources and lower the rates of automotive emissions, but the rising number of vehicles and longer time spent on the road will call for more radical solutions to traffic-generated photochemical smog now present in all major urban areas.

V. Smil

2001-01-01T23:59:59.000Z

64

The Measured Energy Impact of Infiltration Under Dynamic Conditions  

E-Print Network [OSTI]

, the heat transfer process is a complicated non-linear process, and neither the temperature nor the air flow rate is constant. Therefore, the validity of the steady-state methodology should be proved for dynamic condition. As a preliminary step, dynamic...

Liu, M.; Claridge, D. E.

65

Summer Infiltration/Ventilation Test Results from the FRTF Laboratory  

Broader source: Energy.gov (indexed) [DOE]

Summer InfiltrationVentilation Test Results from the FRTF Laboratory Building America Technical Review Meeting April 29-30, 2013 A Research Institute of the University of Central...

66

Impact of Infiltration and Ventilation on Measured Space Conditioning...  

Broader source: Energy.gov (indexed) [DOE]

Hot-humid PERFORMANCE DATA Costs for reducing infiltration and incorporating mechanical ventilation in buildings will vary greatly depending on the condition and...

67

Assessment of organic compound exposures, thermal comfort parameters, and HVAC system-driven air exchange rates in public school portable classrooms in California  

E-Print Network [OSTI]

no no, y e s - only HVAC filters: sizes, when changed 68%n=2) (n=19) 100% no 95% no Current HVAC air filter was notoriginal When HVAC air filter was last changed (reported as

Shendell, Derek Garth

2010-01-01T23:59:59.000Z

68

The effects of aeration time for various airflow rates on the properties of the effluent air from grain aerated in storage  

E-Print Network [OSTI]

Specific Enthalpy of Interstice Air in Relation to Aeration Time when Cooling a Mass of Grain in Storage. . . . . . . 28 Specific Enthalpy of Interstice Air in Relation to Aeration Time when Cooling a Mass of Grain in Storage. . . . . . . 29 Specific... Enthalpy of Interstice Air in Relation to Aeration Time when Cooling a Mass of Grain in Storage. . . . . . . 30 17 Specific Enthalpy of Interstice Air in Relation to Aeration Time when Cooling a Mass of Grain in Storage. . . . . . . 31 18. Cooling Time...

Miller, John Allen

1965-01-01T23:59:59.000Z

69

Sr-90 Immobilization by Infiltration of a Ca-Citrate-PO{sub 4} Solution into the Hanford 100-N Area Vadose Zone  

SciTech Connect (OSTI)

This project was initiated to develop a strategy for infiltration of a Ca-citrate-PO{sub 4} solution in order to precipitate apatite [Ca{sub 6}(PO{sub 4}){sub 10}(OH){sub 2}] in desired locations in the vadose zone for Sr-90 remediation. Laboratory experiments have demonstrated that infiltration of a Ca-citrate-PO{sub 4} solution into sediments at low and high water saturation results in citrate biodegradation and formation of apatite. The citrate biodegradation rate was relatively uniform, in spite of the spatial variability of sediment microbial biomass, likely because of microbial transport processes that occur during solution infiltration. The precipitate was characterized as hydroxyapatite, and the Sr-90 substitution into apatite was shown to have an incorporation half-life of 5.5 to 16 months. One and two dimensional (1-D and 2-D) laboratory infiltration experiments quantified the spatial distribution of apatite that formed during solution infiltration. Slow infiltration in 2-D experiments at low water saturation show the apatite precipitate concentrated in the upper third of the infiltration zone. More rapid 1-D infiltration studies show the apatite precipitate concentrated at greater depth. (authors)

Szecsody, J.E.; Fruchter, J.S.; Burns, C.A.; Rockhold, M.L.; Oostrom, M.; Williams, M.D.; Vermeul, V.R. [Pacific Northwest National Laboratory, Richland, WA (United States)

2008-07-01T23:59:59.000Z

70

Studies in the Respiratory and Carbohydrate Metabolism of Plant Tissues. IV. The Relation between the Rate of Carbon Dioxide Production in Potato Tubers in Air Following Anaerobic Conditions, and the Accompanying Changes in Lactic Acid Content and Sugar Concentration  

Science Journals Connector (OSTI)

...Following Anaerobic Conditions, and the Accompanying Changes in Lactic Acid Content and Sugar Concentration J. Barker A. F. El Saifi In part III of this series data were presented for the changes in air following periods of anaerobiosis in the rate of production...

1953-01-01T23:59:59.000Z

71

Geothermal: Sponsored by OSTI -- Water infiltration and intermittent...  

Office of Scientific and Technical Information (OSTI)

Water infiltration and intermittent flow in rough-walled fractures Geothermal Technologies Legacy Collection HelpFAQ | Site Map | Contact Us | Admin Log On HomeBasic Search About...

72

Air Conditioning  

Science Journals Connector (OSTI)

Air Conditioning ... CHEMISTS and engineers use air conditioning as a valuable tool in more than two hundred industries. ... Air conditioning is a tool with many facets. ...

MARGARET INGELS

1938-02-10T23:59:59.000Z

73

Cleaning Products and Air Fresheners: Emissions and Resulting Concentrations of Glycol Ethers and Terpenoids  

E-Print Network [OSTI]

with realistic air-exchange and product usage rates, theand total rate of air freshener product volatilization (26, 589-597. Cleaning Product and Air Freshener Emissions (

Singer, Brett C.; Destaillat, Hugo; Hodgson, Alfred T.; Nazaroff, William W.

2005-01-01T23:59:59.000Z

74

Procedure for determining the rate of penetration of melts into materials of capillary porosity  

Science Journals Connector (OSTI)

A procedure is proposed for determining the rate of infiltration of melts into porous materials from the change in the electrical resistance of the latter.

M. A. Sherstobitov; S. I. Popel'…

1965-08-01T23:59:59.000Z

75

PROPOSED RESEARCH AGENDA FOR ACHIEVING INDOOR AIR QUALITY SUPPORTING HEALTH AND  

E-Print Network [OSTI]

1 PROPOSED RESEARCH AGENDA FOR ACHIEVING INDOOR AIR QUALITY SUPPORTING HEALTH AND COMFORT IN HIGHLY efficient buildings; Research priorities; Effort; Indoor air quality; Ventilation 1 INTRODUCTION Buildings Group, Lawrence Berkeley National Laboratory, USA 3 VentGuide, the Netherlands 4 Air Infiltration

76

Use of thermal data to estimate infiltration, Yucca Mountain, Nevada  

SciTech Connect (OSTI)

Temperature and pressure monitoring in a vertical borehole in Pagany Wash, Yucca Mountain, Nevada, measured disruptions of the natural gradients associated with the February, 1998, El Nino precipitation events. The temperature and pressure disruptions indicated infiltration and percolation through the 12.1 m of Pagany Wash alluvium and deep percolation to greater than 35.2 m into the Yucca Mountain Tuff.

LeCain, Gary D.; Kurzmack, Mark

2001-04-29T23:59:59.000Z

77

AirTAP BriefingsA publication of the AirTAP program of the Center for Transportation Studies at the University of Minnesota Setting rates and charges can be one of  

E-Print Network [OSTI]

to another airport in the surrounding area. However, setting rates and charges does provide an opportunity for each airport is to develop a policy handbook. A policy handbook is defined as "an approved document for establishing and adjusting rents and fees" (AAAE Rates and Charges Workshop, 2000). The policy handbook serves

Minnesota, University of

78

Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Cooling Season Energy and Moisture Levels  

SciTech Connect (OSTI)

Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

Parker, D.; Kono, J.; Vieira, R.; Fairey, P.; Sherwin, J.; Withers, C.; Hoak, D.; Beal, D.

2014-05-01T23:59:59.000Z

79

Compressed Air  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

BPA Utility Reimbursement Programs for Compressed Air Projects Customer Proposal Template Measurement & Verification Plan for Compressed Air CA 2006-15 A template for utilities to...

80

Fuel consumption rate in a heat-powered unit analyzed as a function of the temperature and consumption ratio of the air  

Science Journals Connector (OSTI)

An analysis of fuel consumption for a heat-powered unit in the ... of ceramic materials is given. The heat consumption rate is analyzed as a function of ... generating the working medium, and of the consumption r...

N. A. Tyutin

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Appendix B Surface Infiltration and Aquifer Test Data  

Office of Legacy Management (LM)

B B Surface Infiltration and Aquifer Test Data This page intentionally left blank Infiltration Tests This page intentionally left blank 0 50 100 150 200 250 300 350 400 450 TIME (MIN) 200 250 TIME (MIN) 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 TIME (MIN) zoo 800 1000 TIME (MIN) 0 150 300 450 600 750 , 900 1050 1200 1350 1500 1650 1800 TIME (MIN) TIME (MIN) 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 TIME (MIN) INF-8 TEST I 300 400 TIME (MIN) INF-8 TEST 2 200 250 300 TIME (MIN) 200 250 TIME (MIN) zoo 800 1000 TIME (MIN) 0 50 100 150 200 250 300 350 400 450 500 550 600 TIME (MIN) 0 50 100 150 200 250 300 350 400 450 500 550 600 TIME (MIN) September 1997 Alluvial Aquifer Tests This page intentionally left blank - - - - - - - - - - - - - - -

82

Synthesis and Stability of a Nanoparticle-Infiltrated Solid Oxide Fuel Cell Electrode  

E-Print Network [OSTI]

Nanoparticle-Infiltrated Solid Oxide Fuel Cell Electrode Talinfiltrated into SOFC (Solid Oxide Fuel Cell) electrodes can

Sholklapper, Tal Z.; Radmilovic, Velimir; Jacobson, Craig P.; Visco, Steven J.; De Jonghe, Lutgard C.

2006-01-01T23:59:59.000Z

83

Infiltration and evaporation of small hydrocarbon spills at gas stations  

Science Journals Connector (OSTI)

Abstract Small gasoline spills frequently occur at gasoline dispensing stations. We have developed a mathematical model to estimate both the amount of gasoline that infiltrates into the concrete underneath the dispensing stations and the amount of gasoline that evaporates into the typically turbulent atmosphere. Our model shows that the fraction of infiltrated gasoline can exceed the fraction that evaporates from the sessile droplets. Infiltrated gasoline then evaporates and is slowly released to the atmosphere via slow diffusive transport in pores. Tentative experiments show that our theoretical approach captures observed experimental trends. Predictions based on independently estimated model parameters roughly describe the experimental data, except for the very slow vapor release at the end of Stage II evaporation. Our study suggests that, over the lifespan of a gas station, concrete pads underneath gas dispensing stations accumulate significant amounts of gasoline, which could eventually break through into underlying soil and groundwater. Our model also shows that lifetimes of spilled gasoline droplets on concrete surfaces are on the order of minutes or longer. Therefore contamination can be carried away by foot traffic or precipitation runoff. Regulations and guidelines typically do not address subsurface and surface contaminations due to chronic small gasoline spills, even though these spills could result in non-negligible human exposure to toxic and carcinogenic gasoline compounds.

Markus Hilpert; Patrick N. Breysse

2014-01-01T23:59:59.000Z

84

Building Technologies Office: Energy-Efficient Window Air Conditioner  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy-Efficient Window Energy-Efficient Window Air Conditioner Ratings Research Project to someone by E-mail Share Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Facebook Tweet about Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Twitter Bookmark Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Google Bookmark Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Delicious Rank Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Digg Find More places to share Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on

85

IMPACT OF REDUCED INFILTRATION AND VENTILATION ON INDOOR AIR QUALITY IN RESIDENTIAL BUILDINGS  

E-Print Network [OSTI]

urea-formaldehyde foam insulation, and radon from variousand urea-formaldehyde foam insulation have recently otherformaldehyde (UF) based foam insulation materials because of

Hollowell, Craig D.

2011-01-01T23:59:59.000Z

86

Effects of Cu and Ga additions to Nb/sub 3/Sn superconductors prepared by infiltration process  

SciTech Connect (OSTI)

The effects of Cu and Ga additions on the superconducting properties of infiltration-processed Nb/sub 3/Sn have been studied. The addition of Cu to the Sn improves the overall critical current density J/sub c/ at entire fields, which is considered to result from the enhancement in Nb/sub 3/Sn growth rate. J/sub c/ of 8 x 10/sup 4/ A/cm/sup 2/ at 4.2 K and 12 T has been obtained for the specimen infiltrated with Sn-20at%Cu alloy. The Ga addition has been found to improve J/sub c/ at high magnetic fields, which is probably a consequence of an increase in the upper critical field H/sub c2/. However, at lower fields J/sub c/ is somewhat lower than that of the specimens without Ga.

Kumakura, H.; Togano, K.; Tachikawa, K.

1981-01-01T23:59:59.000Z

87

Energy savings and cost-effectiveness of heat exchanger use as an indoor air quality mitigation measure in the BPA weatherization program  

Science Journals Connector (OSTI)

The Bonneville Power Administration (BPA) has proposed a ten year program to encourage the weatherization of electrically heated homes in the Pacific Northwest. The purpose of this program is to reduce residential electrical energy demand for space heating. If air infiltration rates are reduced by employing house tightening measures, indoor air quality mitigation measures may be required in residences with significant sources of indoor air contaminants. The use of residential air-to-air heat exchangers has been proposed as a possible strategy to assure that indoor air quality is not substantially degraded by house tightening. We examine the energy impact and cost effectiveness of heat exchanger utilization in tightened homes in the BPA region. Significant energy savings are predicted if homes are tightened and heat exchangers are utilized. From the homeowner's perspective, the results of our economic analysis indicate that, at the relatively low residential electric rates in the BPA region, the use of heat exchangers in existing homes that are tightened is not economically viable. On the other hand, from the utility perspective, it may be cost effective to use heat exchangers in the weatherization program if the marginal cost to the utility is compared with the cost of conserved energy.

Isaac Turiel; William J. Fisk; Mark Seedall

1983-01-01T23:59:59.000Z

88

(1) AGGELIDES, S., YOUNGS, E.G., 1978 -The dependance of the parameters in the Green and Ampt infiltration equation on the initial water content in draining and wetting states.  

E-Print Network [OSTI]

for infiltration through a surface seal permitting transient parameters below the seal ; ASAE Publication Advances measurement of air entry value and hydraulic conductivity of soil as significant parameters in flow system, p.1753-1757. (20) BRIDGE, B.J., SILBURN, DM., 1995 ­Methods for obtaining surface seal hydraulic

Paris-Sud XI, Université de

89

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California: Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure  

E-Print Network [OSTI]

5 III. Current ASHRAE 62.1 Indoor Air Quality Procedure (satisfied with indoor air quality in office buildings inthe U.S. in taking indoor air quality seriously, in the same

Mendell, Mark

2014-01-01T23:59:59.000Z

90

Air Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

What We Monitor & Why » What We Monitor & Why » Air Quality Air Quality To preserve our existing wilderness-area air quality, LANL implements a conscientious program of air monitoring. April 12, 2012 Real-time data monitoring for particulate matter An air monitoring field team member tests one of LANL's tapered element oscillating microbalance samplers, which collects real-time particulate matter data. Contact Environmental Communication & Public Involvement P.O. Box 1663 MS M996 Los Alamos, NM 87545 (505) 667-0216 Email LANL monitors air quality 24 hours a day, 365 days a year. Why we monitor air LANL monitors many different pathways in order to assess their impact on workers, the public, animals, and plants. We monitor the air around the Laboratory to ensure our operations are not affecting the air of nearby

91

TECHNICAL BASIS DOCUMENT NO. 1: CLIMATE AND INFILTRATION  

SciTech Connect (OSTI)

For the past 20 years, extensive field, laboratory, and modeling investigations have been performed at Yucca Mountain, which have led to the development of a number of conceptual models of infiltration and climate for the Yucca Mountain region around the repository site (Flint, A.L. et al. 2001; Wang and Bodvarsson 2003). Evaluating the amount of infiltrating water entering the subsurface is important, because this water may affect the percolation flux, which, in turn, controls seepage into the waste emplacement drifts and radionuclide transport from the repository to the water table. Forecasting of climatic data indicates that during the next 10,000 years at Yucca Mountain, the present-day climate should persist for 400 to 600 years, followed by a warmer and much wetter monsoon climate for 900 to 1,400 years, and by a cooler and wetter glacial-transition climate for the remaining 8,000 to 8,700 years. The analysis of climatic forecasting indicates that long-term climate conditions are generally predictable from a past climate sequence, while short-term climate conditions and weather predictions may be more variable and uncertain. The use of past climate sequences to bound future climate sequences involves several types of uncertainties, such as (1) uncertainty in the timing of future climate, (2) uncertainty in the methodology of climatic forecasting, and (3) uncertainty in the earth's future physical processes. Some of the uncertainties of the climatic forecasting are epistemic (reducible) and aleatoric (irreducible). Because of the size of the model domain, INFIL treats many flow processes in a simplified manner. For example, uptake of water by roots occurs according to the ''distributed model'', in which available water in each soil layer is withdrawn in proportion to the root density in that layer, multiplied by the total evapotranspirative demand. Runoff is calculated simply as the excess of precipitation over a sum of infiltration and water storage in the root zone. More significantly, water movement throughout the soil profile is treated according to the bucket model, in which the amount of water that moves down from one layer to the next is equal to the mass of water in excess of field capacity in the upper layer. The development of a numerical model of infiltration involves a number of abstractions and simplifications to represent the complexity of environmental conditions at Yucca Mountain, such as the arid climate, mountain-type topography, heterogeneous soils and fractured rock, and irregular soil-rock interface.

NA

2004-05-01T23:59:59.000Z

92

Impact of Infiltration and Ventilation on Measured Space Conditioning...  

Energy Savers [EERE]

to provide needed ventilation under drier summer and winter conditions and reduce the air introduced during periods of peak space conditioning. For more information, see the...

93

Effect of Saline Waste Solution Infiltration Rates on Uranium Retention and Spatial Distribution in Hanford Sediments  

E-Print Network [OSTI]

EM/GJ1302-2006, Stoller Hanford Office, Richland, WA. 2006.BY tank farms. CH2M Hill, Hanford Group. Inc. : Richland, WAT. E. ; Kincaid, C. T. Hanford soil inventory model (SIM)

2008-01-01T23:59:59.000Z

94

Effect of Saline Waste Solution Infiltration Rates on Uranium Retention and Spatial Distribution in Hanford Sediments  

E-Print Network [OSTI]

Characterization of vadose zone sediment: Borehole 299-E33-of contaminated Hanford sediments. Environmental Science andU(VI)-contaminated Hanford sediment. Geochimica Cosmochimica

2008-01-01T23:59:59.000Z

95

Transportation Rates For Fishery Products  

E-Print Network [OSTI]

express (Railway Express Agency), and motor carriers. Air transporta- tion and water transportation 2 Rail-freight rates 2 Rail-express rates 3 Motor-carrier rates 3 Protective-service charges 4 used in sample 7 2. Rail-express rate index: Routes used in sample 7 3. Motor-carrier rate index

96

Improvement of SOFC Electrodes through Catalyst Infiltration & Control of Cr Volatilization from FeCr Components  

SciTech Connect (OSTI)

This presentation discusses the improvement of SOFC electrodes through catalyst infiltration and control of Cr volatilization from FeCr components.

Visco, S.J.; Jacobson, C.; Kurokawa, H.; Sholklapper, T.; Lu, C.; De Jonghe, L.

2005-01-28T23:59:59.000Z

97

Factors governing the performance and stability of solid oxide fuel cell cathodes prepared by infiltration.  

E-Print Network [OSTI]

??Infiltration method, developed at the University of Pennsylvania, is a unique analytical platform for investigating the effect of material properties and electrode microstructure on the… (more)

Küngas, Rainer

2012-01-01T23:59:59.000Z

98

Opals infiltrated with a stimuli-responsive hydrogel for ethanol vapor sensing  

Science Journals Connector (OSTI)

We report on a novel class of optical materials for ethanol vapor sensing, based on polystyrene opals infiltrated with an innovative stimuli-responsive hydrogel. We describe the...

Pernice, Riccardo; Adamo, Gabriele; Stivala, Salvatore; Parisi, Antonino; Busacca, Alessandro C; Spigolon, Dario; Sabatino, Maria Antonietta; D’Acquisto, Leonardo; Dispenza, Clelia

2013-01-01T23:59:59.000Z

99

A Prediction of Energy Savings Resulting from Building Infiltration Control  

E-Print Network [OSTI]

, working to reduce or increase it. This study uses simulation to evaluate the potential energy impact of the interaction when several different strategies for controlling air leakage direction and velocity in building envelope components are implemented...

McWatters, K.; Claridge, D. E.; Liu, M.

1996-01-01T23:59:59.000Z

100

On the infiltration of rain water through the soil with runo# of the excess water  

E-Print Network [OSTI]

On the infiltration of rain water through the soil with runo# of the excess water Iacopo Borsi '' Viale Morgagni 67/A, 50134 Firenze, Italy Abstract This paper deals with the modelling of the rain water infiltration through the soil above the aquifer in case of runo# of the excess water. The main feature

Fasano, Antonio

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Rating of Mixed Split Residential Air Conditioners  

E-Print Network [OSTI]

by the indoor fan, the indoor fan is characterized by its power needed to provide this CFM, and the expansion device is characterized by its restrictiveness to the refrigerant flow (explained later). A computer model of a heat pump was used in this study.... The structure of HPSIM is modular. The model consists of 41 subprograms for heat pump component simulation, heat transfer, fluid mechan- ics, and fluid property calculation. The program totals approximately 5000 Fortran statements. UncL -'< Fig. 2...

Domanski, P. A.

1988-01-01T23:59:59.000Z

102

Melt Infiltrated Ceramic Composites (Hipercomp) for Gas Turbine Engine Applications  

SciTech Connect (OSTI)

This report covers work performed under the Continuous Fiber Ceramic Composites (CFCC) program by GE Global Research and its partners from 1994 through 2005. The processing of prepreg-derived, melt infiltrated (MI) composite systems based on monofilament and multifilament tow SiC fibers is described. Extensive mechanical and environmental exposure characterizations were performed on these systems, as well as on competing Ceramic Matrix Composite (CMC) systems. Although current monofilament SiC fibers have inherent oxidative stability limitations due to their carbon surface coatings, the MI CMC system based on multifilament tow (Hi-Nicalon ) proved to have excellent mechanical, thermal and time-dependent properties. The materials database generated from the material testing was used to design turbine hot gas path components, namely the shroud and combustor liner, utilizing the CMC materials. The feasibility of using such MI CMC materials in gas turbine engines was demonstrated via combustion rig testing of turbine shrouds and combustor liners, and through field engine tests of shrouds in a 2MW engine for >1000 hours. A unique combustion test facility was also developed that allowed coupons of the CMC materials to be exposed to high-pressure, high-velocity combustion gas environments for times up to {approx}4000 hours.

Gregory Corman; Krishan Luthra

2005-09-30T23:59:59.000Z

103

Fabrication of superconducting wire using organometallic precursors and infiltration  

SciTech Connect (OSTI)

Organometallic precursors from naphthenic acid and metal nitrates were used for the synthesis of YBCO oxide superconducting compounds. The characteristics of metal naphthenates as organometallic precursors were investigated by IR spectra, viscosity measurements, and infiltration. 123 superconducting compound obtained from 123 naphthenate showed a Tc of 90{degree}K and a rather dense and elongated microstructure. Also, the melting behavior of Ba-cuprates which were used for 123 making was studied. A low-temperature melting process was developed to fabricate silver-sheathed superconducting wire with the powder-in-tube method; flowing argon gas is introduced to the system at 930-945{degree}C to reduce the melting temperature of the 123 compound without silver sheath melting. It resulted in a 90{degree}K Tc superconducting core with dense and locally aligned microstructure. SEM-EDS and XRD analysis, 4-probe resistance and Jc measurements, and carbon-content determinations were carried out to characterize the microstructure, grain alignment, and superconducting properties of the samples.

Lee, Y.J.

1991-01-01T23:59:59.000Z

104

Infiltration Testing of Homes in the Houston Gulf Coast Area  

E-Print Network [OSTI]

Air Changes per Hour (ACH) are determined by construction and weather conditions. In this test, it was found that the ACH is equal to .59 plus .07 for every year of age the home has. The higher ACH values for age are due to deterioration...

Howel, E. S.

1990-01-01T23:59:59.000Z

105

Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate, Cocoa, Florida (Fact Sheet)  

SciTech Connect (OSTI)

Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season. ?

Not Available

2014-04-01T23:59:59.000Z

106

Bos > AIR  

E-Print Network [OSTI]

The advent of air travel has produced a building typology completely new to the 20th century. The outdated planning of regions for airports render most existing airports as isolated, autonomous instances in the urban ...

Lee, Kevin Young

2014-01-01T23:59:59.000Z

107

Air Cooling Technology for Power Electronic Thermal Control  

Broader source: Energy.gov (indexed) [DOE]

Characterization Platform * Air flow rate control * High accuracy heat transfer measurement * Velocity field characterization * Automated control and data acquisition...

108

detonation rate  

Science Journals Connector (OSTI)

detonation rate, detonation velocity, velocity of detonation, V.O.D., detonating velocity, rate of detonation, detonating rate ? Detonationsgeschwindigkeit f

2014-08-01T23:59:59.000Z

109

Olive oil Mill Wastewater properties change during infiltration through clay soils  

Science Journals Connector (OSTI)

Olive oil Mill Wastewaters (OMW), are stored in clay basins in the region of Sfax (Tunisia). Field permeability measurements showed that the clay is not completely impermeable and its structure can be modified by the infiltration of OMW. Analysis of chemical composition of soil revealed the presence of phenolic compounds resulting from the percolation of OMW. An infiltration filled with clay and submerged with OMW at a height of 1.5 m was used to study the composition change of the support as OMW percolates through the clay. Compared to the raw OMW, infiltrated effluent showed a decease of its polluting load.

Adel Kharroubi; Raja Jarboui; Habib Abida; Emna Ammar

2011-01-01T23:59:59.000Z

110

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California: Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure  

E-Print Network [OSTI]

control should be the first priority instead of dilution of pollutants by ventilation or by cleaning the air.air quality, could better provide healthful indoor environments, and also reward designers and owners who control indoor pollutantsair quality, could better document healthful indoor environments, and also reward designers and owners who control indoor pollutants

Mendell, Mark

2014-01-01T23:59:59.000Z

111

Air Resources: Prevention and Control of Air Contamination and Air  

Broader source: Energy.gov (indexed) [DOE]

Air Resources: Prevention and Control of Air Contamination and Air Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York) Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York) < Back Eligibility Agricultural Fuel Distributor Industrial Institutional Investor-Owned Utility Local Government Multi-Family Residential Municipal/Public Utility Nonprofit Rural Electric Cooperative Schools State/Provincial Govt Transportation Tribal Government Utility Program Info State New York Program Type Environmental Regulations Provider NY Department of Environmental Conservation These regulations establish emissions limits and permitting and operational

112

Toward High Performance Thermoset/Carbon Nanotube Sheet Nanocomposites via Resistive Heating Assisted Infiltration and Cure  

Science Journals Connector (OSTI)

Thermoset/carbon nanotube (CNT) sheet nanocomposites were successfully fabricated by resistive heating assisted infiltration and cure (RHAIC) of the polymer matrix resin. Resistive heating takes advantage of the electrical and thermal conductivity of CNTs ...

Jae-Woo Kim; Godfrey Sauti; Emilie J. Siochi; Joseph G. Smith; Russell A. Wincheski; Roberto J. Cano; John W. Connell; Kristopher E. Wise

2014-10-17T23:59:59.000Z

113

Laboratory Testing of Aerosol for Enclosure Air Sealing  

SciTech Connect (OSTI)

Space conditioning energy use can be significantly reduced by addressing uncontrolled infiltration and exfiltration through the envelope of a building. A process for improving the air tightness of a building envelope by sealing shell leaks with an aerosol sealing technology is presented. Both retrofit and new construction applications are possible through applying this process either in attics and crawlspaces or during rough-in stage.

Harrington, C.; Modera, M.

2012-05-01T23:59:59.000Z

114

Obsidian Hydration Rates  

Science Journals Connector (OSTI)

...OBSIDIAN HYDRATION RATE FOR KLAMATH BASIN OF CALIFORNIA AND OREGON...as the material is excreted, falls through the air, and dries...Friedman. Table 1 presents two new groups of hydra-tion readings for...the true age is believed to fall (3). The Snaketown age is...

Clement W. Meighan

1970-10-02T23:59:59.000Z

115

Long Duration Tests of Room Air Filters in Cigarette Smokers' Homes  

Science Journals Connector (OSTI)

Long Duration Tests of Room Air Filters in Cigarette Smokers' Homes ... Between 15 and 40 cigarettes were smoked daily by several smokers in each home. ... Emissions from PM sources in homes may cause much higher concentrations than outdoor PM that infiltrates into the home (18, 42?45. ...

Stuart Batterman; Christopher Godwin; Chunrong Jia

2005-08-06T23:59:59.000Z

116

About the Ratings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2008 Ratings Changes 2008 Ratings Changes EPA's "New" Fuel Economy Ratings Video about EPA's New Fuel Economy Ratings Windows Media Video (6.8 MB) Quicktime Video (7.8 MB) Text Version EPA changed the way it estimates fuel economy starting with the 2008 model year. This "new" way of estimating fuel economy supplements the previous method by incorporating the effects of Faster speeds and acceleration Air conditioner use Colder outside temperatures What else do I need to know about the "new" ratings? The tests lower MPG estimates for most vehicles. View old/new MPG ratings for a specific vehicle The actual mileage you get will still vary based on your driving habits, traffic conditions, and other factors. All MPG estimates in Find-a-Car have been converted to the new

117

E-Print Network 3.0 - air monitoring adjacent Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: ventilation rate on perceived quality of air polluted by different materials, small - scale and full - scale... the ventilation required for acceptable indoor air...

118

Biochemotherapy of metastatic malignant melanoma. Predictive value of tumour-infiltrating lymphocytes  

E-Print Network [OSTI]

Summary The therapeutic efficacy of biochemotherapy in metastatic malignant melanoma still carries a low remission rate, but with some durable responses. It would therefore be of considerable importance if patients with a high probability of responding could be identified using predictive tests. The response to interferon-alpha (IFN-?) correlates with the occurrence of CD4 + lymphocytes identified by fine-needle aspirates from melanoma metastases (Håkansson et al, 1996). The present investigation studies a possible correlation between tumourinfiltrating CD4 + lymphocytes in malignant melanoma metastases and the therapeutic effect of biochemotherapy. A total of 25 patients with systemic and 16 with regional metastatic melanoma were analysed before initiation of biochemotherapy (cis-platinum 30 mg/m2 d.1–3, DTIC 250 mg/m2 d.1–3 i.v. and IFN-?2b 10 million IU s.c. 3 days a week, q. 28d.). A monoclonal antibody, anti-CD4, was used to identify tumourinfiltrating lymphocytes in fine-needle aspirates before start of treatment. The presence of these lymphocytes was correlated to response, time to progression and overall survival. A statistically significant correlation (P = 0.01) was found between the occurrence of CD4 + lymphocytes and tumour regression during biochemotherapy in patients with systemic disease. Out of 14 patients with moderate to high numbers of infiltrating CD4 + lymphocytes, 12 achieved tumour regression. In contrast, among patients with low numbers of these cells in metastatic lesions, 8 out of 11 had progressive disease. We also found a significantly longer time to progression (P < 0.003) and overall survival (P < 0.01) among patients with moderate to high numbers of these cells compared to patients with low numbers of these cells before

A Håkansson; B Gustafsson; L Krys; B Hjelmqvist; B Rettrup; L Håkansson

119

The effects of gasification feedstock chemistries on the infiltration of slag into the porous high chromia refractory and their reaction products  

Science Journals Connector (OSTI)

Abstract Synthetic slags with compositions representative of carbonaceous feedstock derived from coal and petroleum coke were infiltrated into 90%Cr2O3–10%Al2O3 refractory material with a temperature gradient induced along the penetration direction of the slag. Experiments were conducted with a hot-face temperature of 1723 K (1450 °C) in a CO/CO2 gas mixture with a ratio of 1.8, which corresponded to an approximate oxygen partial pressure of 10?8 atm. Interactions between the slags and the refractory produced solid-solution spinel layers on the top interfaces of the refractory samples, whose chemistries reflected the compositions of major constituents of the starting slags. FeCr2O4 formed when samples were infiltrated with slag composition rich in FeO, which was typical for coals derived from eastern USA. (Mg,Fe)Cr2O4 formed when samples were infiltrated with slags, containing considerable concentrations of both MgO and FeO that were common in western US coals. In slags resulted from substituting 50% (by weight) of the coal feedstock by petcoke, similar solid solution phases formed as the pure coal counterparts, but with addition of V2O3, which originated from the petcoke feedstock. The chromium spinel layers, to a reasonable extent, limited infiltration by hindering the slag from flowing into the porous microstructure of the refractory and the formation mechanisms of the product layers were discussed. The Fe(Cr,V)2O4 layer that formed in the presence of petcoke ash exhibited an uneven morphology. As compared to the FeO rich slags, MgO rich slags penetrated further beyond the protective layers and into the refractory. Both of these phenomena could lead to increased refractory spallation rates in actual gasification conditions.

Tetsuya Kenneth Kaneko; Jingxi Zhu; Nathan Howell; Peter Rozelle; Seetharaman Sridhar

2014-01-01T23:59:59.000Z

120

Lithium-Air Battery: High Performance Cathodes for Lithium-Air Batteries  

SciTech Connect (OSTI)

BEEST Project: Researchers at Missouri S&T are developing an affordable lithium-air (Li-Air) battery that could enable an EV to travel up to 350 miles on a single charge. Today’s EVs run on Li-Ion batteries, which are expensive and suffer from low energy density compared with gasoline. This new Li-Air battery could perform as well as gasoline and store 3 times more energy than current Li-Ion batteries. A Li-Air battery uses an air cathode to breathe oxygen into the battery from the surrounding air, like a human lung. The oxygen and lithium react in the battery to produce electricity. Current Li-Air batteries are limited by the rate at which they can draw oxygen from the air. The team is designing a battery using hierarchical electrode structures to enhance air breathing and effective catalysts to accelerate electricity production.

None

2010-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Microsoft Word - Poster Abstract_2010_GATech_LSM-Infiltrated LSCF Cathodes.docx  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and Interfaces and Interfaces in LSM-Infiltrated LSCF Cathodes Wentao Qin, Mingfei Liu, Matthew E. Lynch, Jong-jin Choi and Meilin Liu Center for Innovative Fuel Cell and Battery Technologies School of Materials Science and Engineering Georgia Institute of Technology 771 Ferst Dr., Atlanta, GA 30332-0245 Telephone: 404-894-6114 Email: meilin.liu@mse.gatech.edu Recent studies suggest that the stability and performance of a porous La x Sr 1-x Co y Fe 1-y O 3- (LSCF) cathode may be enhanced by the infiltration of a thin-film La x Sr 1-x MnO 3- (LSM) coating. However, the mechanism of the observed enhancement is still unknown. This poster will present our recent findings in microanalyses of the structure, composition, and morphology of the LSM and LSCF surfaces as well as the LSM/LSCF interfaces in LSM-infiltrated LSCF cathodes. Results indicate that a

122

Rate Schedules  

Broader source: Energy.gov [DOE]

One of the major responsibilities of Southeastern is to design, formulate, and justify rate schedules. Repayment studies prepared by the agency determine revenue requirements and appropriate rate...

123

Air Leakage of Furnaces and Air Handlers  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Air Leakage of Furnaces and Air Handlers Air Leakage of Furnaces and Air Handlers Title Air Leakage of Furnaces and Air Handlers Publication Type Journal Article LBNL Report Number LBNL-5553E Year of Publication 2010 Authors Walker, Iain S., Mile Lubliner, Darryl J. Dickerhoff, and William W. Delp Journal 2010 ACEEE Summer Study on Energy Efficiency in Buildings The Climate for efficiency is now Date Published 08/2010 Abstract In recent years, great strides have been made in reducing air leakage in residential and to a lesser extent small commercial forced air duct systems. Several authorities have introduced low leakage limits for thermal distribution systems; for example, the State of California Energy Code for Buildings gives credit for systems that leak less than 6% of the total air flow at 25 Pa.

124

Rates - WAPA-137 Rate Order  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

WAPA-137 Rate Order WAPA-137 Rate Order 2009 CRSP Management Center Customer Rates Second Step Presentation from the June 25, 2009, Customer Meeting Handout Materials from the June 25, 2009, Customer Meeting Customer Comment Letters ATEA CREDA Farmington ITCA AMPUA Rate Adjustment Information The second step of WAPA-137 SLCA/IP Firm Power, CRSP Transmission and Ancillary Services rate adjustment. FERC Approval of Rate Order No. WAPA-137 Notice Of Filing for Rate Order No. WAPA-137 Published Final FRN for Rate Order No. WAPA-137 Letter to Customers regarding the published Notice of Extension of Public Process for Rate Order No. WAPA-137 Published Extension of Public Process for Rate Order No. WAPA-137 FRN Follow-up Public Information and Comment Forum Flier WAPA-137 Customer Meetings and Rate Adjustment Schedule

125

Engineering report single-shell tank farms interim measures to limit infiltration through the vadose zone  

SciTech Connect (OSTI)

Identifies, evaluates and recommends interim measures for reducing or eliminating water sources and preferential pathways within the vadose zone of the single-shell tank farms. Features studied: surface water infiltration and leaking water lines that provide recharge moisture, and wells that could provide pathways for contaminant migration. An extensive data base, maps, recommended mitigations, and rough order of magnitude costs are included.

HAASS, C.C.

1999-10-14T23:59:59.000Z

126

Parametric analysis of a 1-D infiltration model for Yucca Mountain  

SciTech Connect (OSTI)

Hydrogeological properties of the formations at Yucca Mountain have been previously characterized by log-normal distributions. Different realizations of the randomly described formation may assume different hydrological behaviors, and different property variations may exert influences of different significance levels. This study presents a parametric sensitivity and uncertainty analyses of steady-state infiltration through a representative column of the formations at Yucca Mountain.

Xiang, Yangyong; Mishra, S.

1996-08-01T23:59:59.000Z

127

Metal-Air Batteries  

SciTech Connect (OSTI)

Metal-air batteries have much higher specific energies than most currently available primary and rechargeable batteries. Recent advances in electrode materials and electrolytes, as well as new designs on metal-air batteries, have attracted intensive effort in recent years, especially in the development of lithium-air batteries. The general principle in metal-air batteries will be reviewed in this chapter. The materials, preparation methods, and performances of metal-air batteries will be discussed. Two main metal-air batteries, Zn-air and Li-air batteries will be discussed in detail. Other type of metal-air batteries will also be described.

Zhang, Jiguang; Bruce, Peter G.; Zhang, Gregory

2011-08-01T23:59:59.000Z

128

Air Pollution Control  

Science Journals Connector (OSTI)

Petroleum and chemical processes are responsible for many emissions both into the air. Most relevant emissions into the air are nitrous oxides (NOx), sulfur oxides ... compounds (VOC).The major cause of all air pollution

Alireza Bahadori

2014-01-01T23:59:59.000Z

129

Hickam Air Force Base  

Broader source: Energy.gov [DOE]

Hickam Air Force Base spans 2,850 acres in Honolulu, Hawaii. The military base is home to the 15th Airlift Wing, the Hawaii Air National Guard, and the Pacific Air Forces headquarters.

130

OLYMPIC AIR QUALITY QUESTIONABLE  

Science Journals Connector (OSTI)

OLYMPIC AIR QUALITY QUESTIONABLE ... Athletes GOING FOR GOLD worry about Beijing’s air ... Atmospheric chemists say the air quality during the Beijing Games literally rests on which direction the winds blow. ...

RACHEL PETKEWICH

2008-07-28T23:59:59.000Z

131

Air Quality and Pollution  

Science Journals Connector (OSTI)

Air quality refers to the physical, chemical, and biological characteristics of air, both in outside space and in enclosed ... other non?industrial working places, and residencies. Air pollution is the abnormal ...

Zoran Marmut

2008-01-01T23:59:59.000Z

132

Primary zone air proportioner  

DOE Patents [OSTI]

An air proportioner is provided for a liquid hydrocarbon fueled gas turbine of the type which is convertible to oil gas fuel and to coal gas fuel. The turbine includes a shell for enclosing the turbine, an air duct for venting air in said shell to a gasifier, and a fuel injector for injecting gasified fuel into the turbine. The air proportioner comprises a second air duct for venting air from the air duct for mixing with fuel from the gasifier. The air can be directly injected into the gas combustion basket along with the fuel from the injector or premixed with fuel from the gasifier prior to injection by the fuel injector.

Cleary, Edward N. G. (San Diego, CA)

1982-10-12T23:59:59.000Z

133

E-Print Network 3.0 - air vents discharge Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1519 6.2. Compressed air energy storage... and discharge rates for many cycles. Indeed, the high cycling...

134

Preliminary Analysis of U.S. Residential Air Leakage Database v.2011  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Preliminary Analysis of U.S. Residential Air Leakage Database v.2011 Preliminary Analysis of U.S. Residential Air Leakage Database v.2011 Title Preliminary Analysis of U.S. Residential Air Leakage Database v.2011 Publication Type Conference Proceedings LBNL Report Number LBNL-5552E Year of Publication 2011 Authors Chan, Wanyu R., and Max H. Sherman Conference Name 2011 32nd AIVC Conference and 1st TightVent Conference: Towards Optimal Airtightness Performance Date Published 10/2011 Conference Location Brussels, Belgium. Keywords air leakage, blower door, fan pressurization measurements, infiltration Abstract Air leakage and other diagnostic measurements are being added to LBNL's Residential Diagnostics Database (ResDB). We describe the sources of data that amount to more than 80,000 blower door measurements. We present summary statistics of selected parameters, such as floor area and year built. We compare the house characteristics of new additions to ResDB with prior data. Distributions of normalized leakage are computed for income-qualified homes that were weatherized, homes that were participants of various residential energy efficiency programs, and new constructions built between 2006 and 2011. Further work is underway to relate air leakage to house characteristics utilizing the full database for predictive modeling of air infiltration and to support studies of energy efficiency. Current status of ResDB can be found at http://resdb.lbl.gov/.

135

Air Tightness of New U.S. Houses: A Preliminary Report  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Tightness of New U.S. Houses: A Preliminary Report Tightness of New U.S. Houses: A Preliminary Report Title Air Tightness of New U.S. Houses: A Preliminary Report Publication Type Report LBNL Report Number LBNL-48671 Year of Publication 2002 Authors Sherman, Max H., and Nance Matson Abstract Most dwellings in the United States are ventilated primarily through leaks in the building shell (i.e., infiltration) rather than by whole-house mechanical ventilation systems. Consequently, quantification of envelope air-tightness is critical to determining how much energy is being lost through infiltration and how much infiltration is contributing toward ventilation requirements. Envelope air tightness and air leakage can be determined from fan pressurization measurements with a blower door. Tens of thousands of unique fan pressurization measurements have been made of U.S. dwellings over the past decades. LBNL has collected the available data on residential infiltration into its Residential Diagnostics Database, with support from the U.S. Department of Energy. This report documents the envelope air leakage section of the LBNL database, with particular emphasis on new construction. The work reported here is an update of similar efforts carried out a decade ago, which used available data largely focused on the housing stock, rather than on new construction. The current effort emphasizes shell tightness measurements made on houses soon after they are built. These newer data come from over two dozen datasets, including over 73,000 measurements spread throughout a majority of the U.S. Roughly one-third of the measurements are for houses identified as energy-efficient through participation in a government or utility program. As a result, the characteristics reported here provide a quantitative estimate of the impact that energy-efficiency programs have on envelope tightness in the US, as well as on trends in construction.

136

Rate schedule  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Firm Power Service Provided by Rate/Charges Firm Power Service Provided by Rate/Charges Rate/Charges Effective Through (or until superceded) Firm Sales (SLIP-F9) Composite Rate SLIP 29.62 mills/kWh 9/30/2015 Demand Charge SLIP $5.18/kW-month 9/30/2015 Energy Charge SLIP 12.19 mills/kWh 9/30/2015 Cost Recovery Charge (CRC) SLIP 0 mills/kWh 9/30/2015 Transmission Service Provided by Current Rates effective10/12 - 9/15 (or until superceded) Rate Schedule Effective Through Firm Point-to-Point Transmission (SP-PTP7) CRSP $1.14 per kW-month $13.69/kW-year $0.00156/kW-hour $0.04/kW-day $0.26/kW-week 10/1/2008-9/30/2015 Network Integration Transmission (SP-NW3) CRSP see rate schedule 10/1/2008-9/30/2015 Non-Firm Point-to-Point Transmission (SP-NFT6) CRSP see rate schedule 10/1/2008-9/30/2015 Ancillary Services Provided by Rate Rate Schedule

137

7-29 A coal-burning power plant produces 300 MW of power. The amount of coal consumed during a one-day period and the rate of air flowing through the furnace are to be determined.  

E-Print Network [OSTI]

7-11 7-29 A coal-burning power plant produces 300 MW of power. The amount of coal consumed during The heating value of the coal is given to be 28,000 kJ/kg. Analysis (a) The rate and the amount of heat inputs'tQQ The amount and rate of coal consumed during this period are kg/s48.33 s360024 kg10893.2 MJ/kg28 MJ101.8 6

Bahrami, Majid

138

Pore-Level Modeling of Carbon Dioxide Infiltrating the Ocean Floor  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Infiltrating the Ocean Floor Infiltrating the Ocean Floor Grant S. Bromhal, Duane H. Smith, US DOE, National Energy Technology Laboratory, Morgantown, WV 26507-0880; M. Ferer, Department of Physics, West Virginia University, Morgantown, WV 26506-6315 Ocean sequestration of carbon dioxide is considered to be a potentially important method of reducing greenhouse gas emissions (US DOE, 1999). Oceans are currently the largest atmospheric carbon dioxide sink; and certainly, enough storage capacity exists in the oceans to hold all of the CO 2 that we can emit for many years. Additionally, technologies exist that allow us to pump liquid CO 2 into the oceans at depths between one and two kilometers for extended periods of time and five times that deep for shorter durations. The biggest unknown in the ocean sequestration process, however, is the fate and

139

Lattice Boltzmann simulations on the role of channel structure for reactive capillary infiltration  

E-Print Network [OSTI]

It is widely recognized that the structure of porous media is of relevance for a variety of mechanical and physical phenomena. The focus of the present work is on capillarity, a pore-scale process occurring at the micron scale. We attempt to characterize the influence of pore shape for capillary infiltration by means of Lattice Boltzmann simulations in 2D. This problem is far from being trivial since, for example, round shapes tend to minimize the surface, but solid edges are subjected to pinning, altering strongly capillary infiltration. Another source of complexity comes into play by considering reactive boundaries leading to surface growth and ultimately to pore closure. The systems under investigation consist of single channels with different simplified morphologies: namely, periodic profiles with sinusoidal, step-shaped and zig-zag walls, as well as constrictions and expansions with rectangular, convex and concave steps. The simulations show that the optimal configuration for the pore structure arises fr...

Sergi, Danilo; Leidi, Tiziano; Ortona, Alberto

2014-01-01T23:59:59.000Z

140

Green infrastructure life cycle assessment: A bio-infiltration case study  

Science Journals Connector (OSTI)

This paper presents life cycle assessment (LCA) as a methodology to evaluate environmental, economic, and social performance of green infrastructure stormwater control measures (SCMs). A case study examining a bio-infiltration rain garden at the Villanova University Campus is offered to demonstrate this methodology. The scope of this analysis is cradle to grave benefits and impacts of green infrastructure. Metrics used in this case study to evaluate benefits and impacts include carbon footprint (global warming potential), acidification potential, human health cancer impact, human health non-cancer impact, respiratory effects, eutrophication potential, ozone depletion potential, eco-toxicity, smog formation potential, labor impacts, and life cycle economic costs. Results of this bio-infiltration rain garden case study show that the construction phase is the main contributing life cycle phase for all adverse environmental impacts, as well as total life cycle cost and labor impacts. The majority of these construction phase environmental impacts are attributed to the use of silica sand as a soil amendment for the rain garden media and the use of bark mulch to provide ground cover, repress invasive vegetation, and establish target vegetation. The bio-infiltration rain garden operation phase was found to provide significant avoided environmental impacts relative to the construction phase impacts. These avoided impacts are attributed to urban forest benefits from rain garden vegetation, benefits due to stormwater runoff pollutant treatment by the practice, and benefits to combined sewer systems due to reduced stormwater volume through infiltration and evapo-transpiration. Consideration of multiple rain garden decommissioning phase scenarios makes a case to support the onsite reuse on rain garden media at the end of the practice life.

Kevin M. Flynn; Robert G. Traver

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Air Pollution Spring 2010  

E-Print Network [OSTI]

and control. 6. Examine regional and global air pollution issues. Prerequisite: CHEM 113 and (MATH 261 or MATHATS 555 Air Pollution Spring 2010 T Th 11:00 ­ 12:15, NESB 101 Instructor: Prof. Sonia Kreidenweis an understanding of types and sources of air pollution. 2. Examine concentrations of air pollutants

142

A dual pore carbon aerogel based air cathode for a highly rechargeable lithium-air battery  

Science Journals Connector (OSTI)

Abstract Cathode structure plays a vital role in lithium-air battery for that it can provide space for discharged products accommodation and free path for oxygen, e? and Li+ transport. However, pore blockage, cathode passivation and degradation all result in low discharge rates and poor cycling capability. To get rid of these predicaments, a novel highly conductive dual pore carbon aerogel based air cathode is fabricated to construct a lithium-air battery, which exhibits 18 to 525 cycles in the LiTFSI/sulfolane electrolyte at a current density varying from 1.00 mA cm?2 to 0.05 mA cm?2, accompanied by a high energy efficiency of 78.32%. We postulate that the essence lies in that the as-prepared air cathode inventively create a suitable tri-phase boundary reaction zone, facilitating oxygen and Li+ diffusion in two independant pore channels, thus realizing a relative higher discharge rate capability, lower pore blockage and cathode passivation. Further, pore structure, carbon loading, rate capability, discharge depth and the air's effect are exploited and coordinated, targeting for a high power and reversible lithium-air battery. Such nano-porous carbon aerogel air cathode of novel dual pore structure and material design is expected to be an attractive alternative for lithium-air batteries and other lithium based batteries.

Fang Wang; Yang-Hai Xu; Zhong-Kuan Luo; Yan Pang; Qi-Xing Wu; Chun-Sheng Liang; Jing Chen; Dong Liu; Xiang-hua Zhang

2014-01-01T23:59:59.000Z

143

Air Electrode Design for Sustained High Power Operation of Li/air Batteries  

SciTech Connect (OSTI)

The rapid development of portable electronic devices increasingly requires much more energy to support advanced functions. However, currently available batteries do not meet the high energy requirement of these devices. Metal/air batteries, especially Li/air batteries, have a much higher specific energy than most other available batteries, but their power rate is limited by the accumulation of reaction products in the air electrode. Several approaches to improve the power rate of Li/air batteries have been analyzed in this work, including adjustment of air electrode porosity and catalyst reactivity distributions to minimize diffusion limitations and maximize air electrode material utilization. An interconnected dual pore system (one catalyzed and one noncatalyzed) is proposed to improve oxygen transport into the inner regions of the air electrode, but this approach alone cannot supply high power for long term applications. A time-release multiple catalyst approach is analyzed to provide temporal release of reactivity in the air electrode. When coupled with the dual pore configuration and catalysts with high reactivities, the time-release catalyst concept can extend the duration of higher powers to longer times, and result in maximum utilization of air electrode materials.

Williford, Ralph E.; Zhang, Jiguang

2009-08-31T23:59:59.000Z

144

Utility Rate Discounts | Open Energy Information  

Open Energy Info (EERE)

Discounts Discounts Jump to: navigation, search A few electric utilities offer rate discounts to encourage residential energy efficiency. For homes that meet certain energy efficiency criteria, such as those established by the federal Energy Star program, the owner or tenant is awarded a percentage discount on each month’s electric bill. [1] Contents 1 Utility Rate Discount Incentives 2 References Utility Rate Discount Incentives CSV (rows 1 - 14) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Cleco Power - Power Miser New Home Program (Louisiana) Utility Rate Discount Louisiana Residential Building Insulation Central Air conditioners Clothes Washers Comprehensive Measures/Whole Building Doors Duct/Air sealing Furnaces Heat pumps

145

Healthy Air Act (Maryland)  

Broader source: Energy.gov [DOE]

The Maryland Healthy Air Act was developed with the purpose of bringing Maryland into attainment with the National Ambient Air Quality Standards (NAAQS) for ozone and fine particulate matter by the...

146

Air and Water Pollution  

Science Journals Connector (OSTI)

Air Pollution.... Many pollutants enter our bodies through the air we breathe at 13,000 l/day ... to quantitatively understand the basic environmental physics of pollution. This chapter covers the foll...

David Hafemeister

2014-01-01T23:59:59.000Z

147

Aesculap, Inc. Air Products  

E-Print Network [OSTI]

Aesculap, Inc. Air Products Air Products Foundation Alaric Compliance Services, LLC Alvin H. Butz & Herger, Inc. Sodexo Campus Services Sodexo Inc. and Affiliates Stupp Bros., Inc. Sugarbush Products, Inc

Napier, Terrence

148

Solid oxide fuel cells having porous cathodes infiltrated with oxygen-reducing catalysts  

DOE Patents [OSTI]

Solid-oxide fuel cells include an electrolyte and an anode electrically coupled to a first surface of the electrolyte. A cathode is provided, which is electrically coupled to a second surface of the electrolyte. The cathode includes a porous backbone having a porosity in a range from about 20% to about 70%. The porous backbone contains a mixed ionic-electronic conductor (MIEC) of a first material infiltrated with an oxygen-reducing catalyst of a second material different from the first material.

Liu, Meilin; Liu, Ze; Liu, Mingfei; Nie, Lifang; Mebane, David Spencer; Wilson, Lane Curtis; Surdoval, Wayne

2014-08-12T23:59:59.000Z

149

A loss-based, magnetic field sensor implemented in a ferrofluid infiltrated microstructured polymer optical fiber  

SciTech Connect (OSTI)

We report an in-fiber magnetic field sensor based on magneto-driven optical loss effects, while being implemented in a ferrofluid infiltrated microstructured polymer optical fiber. We demonstrate that magnetic field flux changes up to 2000 gauss can be detected when the magnetic field is applied perpendicular to the fiber axis. In addition, the sensor exhibits high polarization sensitivity for the interrogated wavelengths, providing the possibility of both field flux and direction measurements. The underlying physical and guidance mechanisms of this sensing transduction are further investigated using spectrophotometric, light scattering measurements, and numerical simulations, suggesting photonic Hall effect as the dominant physical, transducing mechanism.

Candiani, A. [Foundation for Research and Technology-Hellas (FORTH), Institute of Electronic Structure and Laser (IESL), Heraklion 70013 Greece (Greece); Department of Information Engineering (DII), University of Parma, Parma 43124 (Italy); Argyros, A.; Leon-Saval, S. G.; Lwin, R. [Institute of Photonics and Optical Science (IPOS), School of Physics, The University of Sydney, Sydney (Australia); Selleri, S. [Department of Information Engineering (DII), University of Parma, Parma 43124 (Italy); Pissadakis, S., E-mail: pissas@iesl.forth.gr [Foundation for Research and Technology-Hellas (FORTH), Institute of Electronic Structure and Laser (IESL), Heraklion 70013 Greece (Greece)

2014-03-17T23:59:59.000Z

150

Building America Whole-House Solutions for New Homes: Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings, Upstate New York  

Broader source: Energy.gov [DOE]

In this project, the Consortium for Advanced Residential Buildings team sought to create a well-documented design and implementation strategy for air sealing in low-rise multifamily buildings that would assist in compliance with new building infiltration requirements of the 2012 IECC.

151

Minimize Compressed Air Leaks  

Broader source: Energy.gov [DOE]

This tip sheet outlines a strategy for compressed air leak detection and provides a formula for cost savings calculations.

152

Air Products effective way  

E-Print Network [OSTI]

PE O A e s a b O T A O ENNST Overview Air Products effective way standard me Departm Shipping has recently y of shipping eans. Air Pro ontainer that es of this pro onduct mark eep accelera eep the cost tilize widely a earch and m m visited Air er needs wer model was cr m approache ms

Demirel, Melik C.

153

Determining the Right Air Quality for Your Compressed Air System  

Broader source: Energy.gov [DOE]

This tip sheet outlines the main factors for determining the right air quality for compressed air systems.

154

Test and Reconstruction of Air Conditioning System in a Hotel Lobby  

E-Print Network [OSTI]

Two air conditioning systems are equipped in a hotel lobby. It is found from the field test that the actual air rate is 40% and 16% of the nominal value, respectively, of the two systems, which is far lower than the design requirement. The air rate...

Wang, G.; Hu, Y.; Hu, S.; Chen, Q.

2006-01-01T23:59:59.000Z

155

Thin Air Breathing  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Thin Air Breathing Thin Air Breathing Name: Amy Location: N/A Country: N/A Date: N/A Question: Why is it hard to breathe in thin air? What health dangers do mountain climbers face at high altitudes? Replies: Among the obvious dangers of losing ones footing, the oxygen available in the air is considerable less at higher altitudes. If I recall correctly, 21% of the atmosphere at standard temperature and pressure at sea level is composed of oxygen. This is less at higher altitudes. One can lose consciousness and even die in an oxygen deficient environment with changes from oxygen content to lower than 19.5%. This can unfortunate effect can occur within minutes. Dr. Myron The air is not really thin at high altitudes. The problem is that air pressure is lower. As altitude increases, air pressure decreases. In order for your lungs to fill with air, the air pressure in your lungs has to be less than the pressure of the air outside your lungs. Air moves from areas of higher pressure to lower pressure. As your diaphragm (the muscle that separates your chest cavity from your abdominal cavity) moves downward, the size of your chest cavity increases. This decreases the pressure in your chest and air flows in. When the diaphragm is up, it puts pressure on the chest cavity and the pressure in the lungs is greater than outside the lungs. Air flows out. This is an example of Boyle's Law. The movement of the diaphragm is controlled by the brainstem. Anyway-the reason that it is harder for some people to breathe at higher altitudes is that the air pressure differences aren't as great between the inside of the lungs and outside.

156

Use of Air2Air Technology to Recover Fresh-Water from the Normal Evaporative Cooling Loss at Coal-Based Thermoelectric Power Plants  

SciTech Connect (OSTI)

This program was undertaken to build and operate the first Air2Air{trademark} Water Conservation Cooling Tower at a power plant, giving a validated basis and capability for water conservation by this method. Air2Air{trademark} water conservation technology recovers a portion of the traditional cooling tower evaporate. The Condensing Module provides an air-to-air heat exchanger above the wet fill media, extracting the heat from the hot saturated moist air leaving in the cooling tower and condensing water. The rate of evaporate water recovery is typically 10%-25% annually, depending on the cooling tower location (climate).

Ken Mortensen

2009-06-30T23:59:59.000Z

157

Residential Forced Air System Cabinet Leakage and Blower Performance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Residential Forced Air System Cabinet Leakage and Blower Performance Residential Forced Air System Cabinet Leakage and Blower Performance Title Residential Forced Air System Cabinet Leakage and Blower Performance Publication Type Report LBNL Report Number LBNL-3383E Year of Publication 2010 Authors Walker, Iain S., Darryl J. Dickerhoff, and William W. Delp Publisher Lawrence Berkeley National Laboratory City Berkeley Keywords air flow measurement, air leakage, blower power measurement, blowers, energy performance of buildings group, forced air systems, furnaces, indoor environment department, other, public interest energy research (pier) program, residential hvac Abstract This project evaluated the air leakage and electric power consumption of Residential HVAC components, with a particular focus on air leakage of furnace cabinets. Laboratory testing of HVAC components indicated that air leakage can be significant and highly variable from unit to unit - indicating the need for a standard test method and specifying maximum allowable air leakage in California State energy codes. To further this effort, this project provided technical assistance for the development of a national standard for Residential HVAC equipment air leakage. This standard is being developed by ASHRAE and is called "ASHRAE Standard 193P - Method of test for Determining the Air Leakage Rate of HVAC Equipment". The final part of this project evaluated techniques for measurement of furnace blower power consumption. A draft test procedure for power consumption was developed in collaboration with the Canadian General Standards Board: CSA 823 "Performance Standard for air handlers in residential space conditioning systems".

158

NREL: Photovoltaics Research - Photovoltaic Energy Ratings Methods  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Photovoltaic Energy Ratings Methods Validation Photovoltaic Energy Ratings Methods Validation The Photovoltaic (PV) Engineering group at NREL validates energy ratings methods by standards committees to establish an energy rating methodology. We are evaluating techniques to account for the impact on PV performance from variations in the spectral distribution of solar radiation. Two types of methods were evaluated for correcting the short-circuit current of PV modules for variations in the solar spectrum under clear skies: (1) empirical relationships based on air mass, and (2) use of spectral irradiance models and PV module spectral response data. Methods of the first type were the Sandia National Laboratories absolute air-mass function, or f(AMa), and the CREST air-mass function, or f(AM). The second

159

Environmental Quality: Air (Louisiana)  

Broader source: Energy.gov [DOE]

The Department of Environmental Quality regulates air quality in Louisiana. The Department has an established a fee system for funding the monitoring, investigation and other activities required...

160

Air-Quality Regulations  

Science Journals Connector (OSTI)

n...Federal, state and/or local regulations constructed for the purpose of protecting air quality, e.g., low volatile organic compounds...

Jan W. Gooch

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Air-quality regulations  

Science Journals Connector (OSTI)

n....Federal, state and/or local regulations constructed for the purpose of protecting air quality, e.g., low volatile organic compounds...

2007-01-01T23:59:59.000Z

162

Use of Personal-Indoor-Outdoor Sulfur Concentrations to Estimate the Infiltration Factor and Outdoor Exposure Factor for Individual Homes and Persons  

Science Journals Connector (OSTI)

Use of Personal-Indoor-Outdoor Sulfur Concentrations to Estimate the Infiltration Factor and Outdoor Exposure Factor for Individual Homes and Persons ...

Lance Wallace; Ron Williams:?

2005-05-12T23:59:59.000Z

163

Improving Air Conditioner and Heat Pump Modeling  

Broader source: Energy.gov (indexed) [DOE]

Improving Air-Conditioner Improving Air-Conditioner and Heat Pump Modeling Building America Stakeholders Meeting Jon Winkler March 2, 2012 2 * How do you recommend the most cost-effective A/C? Simple Question 3 Solution Whole-House Simulation Tool A/C Information * SEER 13 * SEER 14 * SEER 15 * SEER 16 * SEER 17 * SEER 18 * SEER 21 Annualized Cooling Cost (Energy + Equipment) 4 Background * Power, capacity and SHR vary with: o Outdoor temperature o Entering wetbulb o Air mass flow rate o Part load ratio Power Sensible Capacity Latent Capacity * How to accurately and easily model A/C performance? 5 Background: Model Development * A/C modeling utilizes two types of input o Rated values (capacity, efficiency, etc.) o Performance curves Capacity 1 / Efficiency 6 Background: Manufacturer's Data

164

Combustion Safety for Appliances Using Indoor Air (Fact Sheet)  

SciTech Connect (OSTI)

This measure guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate measure guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

Not Available

2014-05-01T23:59:59.000Z

165

Air quality in the Carlsbad cavern  

SciTech Connect (OSTI)

The air quality in the Carlsbad Cavern has been investigated, but there are no reports on radon progeny and aerosols. The purpose of this experiment was to determine the activity size distribution of radon progeny and the air exchange rate inside the Cavern. Teams from ITRI and New Mexico Institute of Mining and Technology (NMT) conducted the field study in July 1994. The ITRI graded diffusion battery (GDB) was used to determine the activity size distribution, progeny concentration, equilibrium factor, and unattached fraction of the radon progeny. The design, calibration, and performance of the GDB have been described. For this study, each stage of the GDB contained one stainless steel screen, with the mesh sizes arranged in a series of 30, 50, 145, 200, and 635 mesh from the air inlet to the outlet. A 47-nm type A/E glass fiber filter was used to collect all particles that penetrated the screens. The flow rate was 5 L/min. The average ventilation rate in the cavern is 0.0026 V/hr. Our results showed that the cavern atmosphere may be quite different from other underground environments. The atmosphere in the summer is stable and relatively free of airborne particles, partly due to the extremely slow air exchange rate.

Cheng, Yung-Seng; Chen, Tou-Rong [Tsing-Hua Univ. (Taiwan, Province of China); Wasiolek, P.T. [New Mexico Institute of Mining and Technology, Socorro, NM (United States)

1994-11-01T23:59:59.000Z

166

Analysis of Air Leakage Measurements from Residential  

E-Print Network [OSTI]

that are rated for energy efficiency have normalized leakage values that are, on average, 30% lower than non% of the total energy consumption by US households, and air leakage is estimated to account for 30 to 50 homes. This work enables software tools such as Home Energy Saver to more reliably predict the energy

167

International MODIS and AIRS processing package: AIRS products and applications  

E-Print Network [OSTI]

International MODIS and AIRS processing package: AIRS products and applications Elisabeth Weisz presented and discussed in this paper demonstrate that the IMAPP AIRS retrieval product is rigorously parameters from the operational AIRS L2 product and data from other instruments. Keywords: AIRS, IMAPP

Li, Jun

168

Clean air act and National Ambient Air Quality Standards (NAAQS)  

E-Print Network [OSTI]

Clean air act and National Ambient Air Quality Standards (NAAQS) Ozone: Sources/Environmental Effects Particulates (PM): Sources/Environmental Effects #12;National Ambient Air Quality Standards (NAAQS) The Clean Air Act requires EPA to set National Ambient Air Quality Standards for pollutants considered

Weber, Rodney

169

Air Exchange Rates in New Energy-Efficient Manufactured Housing  

E-Print Network [OSTI]

During the 1989-1990 heating season, Pacific Northwest Laboratory, for the Bonneville Power Administration, measured the ventilation characteristics of 139 newly constructed energy-efficient manufactured homes and a control sample of 35 newer...

Hadley, D. L.; Bailey, S. A.

1990-01-01T23:59:59.000Z

170

Compressed Air System Optimization  

E-Print Network [OSTI]

Several years ago I went to a gas station and noticed that my car's tires were low on air. I saw the gas station had an air compressor, but it cost a quarter to use the compressor. I paid my quarter and used the compressor. I realized...

Aegerter, R.

171

Recirculating electric air filter  

DOE Patents [OSTI]

An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

Bergman, W.

1985-01-09T23:59:59.000Z

172

Portable oven air circulator  

DOE Patents [OSTI]

A portable air circulating apparatus for use in cooking ovens which is used to create air currents in the oven which transfer heat to cooking foodstuffs to promote more rapid and more uniform cooking or baking, the apparatus including a motor, fan blade and housing of metallic materials selected from a class of heat resistant materials.

Jorgensen, Jorgen A. (Bloomington, MN); Nygren, Donald W. (Minneapolis, MN)

1983-01-01T23:59:59.000Z

173

Factors Analysis on Safety of Indoor Air Quality  

E-Print Network [OSTI]

inhabitants of two healthy buildings. He discovered that the rate of inhabitant with sick building symptom was 7.12%? 14.9% for a building with fresh air input of 34 m3/(h? p), however, 11%? 14.5% for another building with fresh air input of 85 m3/(h? p...

Luo, Q.; Liu, Z.; Xiong, J.

2006-01-01T23:59:59.000Z

174

Meeting the Air Leakage  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Meeting the Air Leakage Meeting the Air Leakage Requirements of the 2012 IECC The U.S. Department of Energy (DOE) recognizes the enormous potential that exists for improving the energy efficiency, safety and comfort of homes. The newest edition of the International Energy Conservation Code ® (IECC) (2012) sets the bar higher for energy efficiency, and new air sealing requirements are one of the key new provisions. This guide is a resource for understanding the new air leakage requirements in the 2012 IECC and suggestions on how these new measures can be met. It also provides information from Building America's Air Sealing Guide, Best Practices and case studies on homes that are currently meeting the provisions. The 2012 IECC and a few International Residential Code (IRC) requirements are referenced throughout the guide.

175

Air and water cooled modulator  

DOE Patents [OSTI]

A compact high power magnetic compression apparatus and method for delivering high voltage pulses of short duration at a high repetition rate and high peak power output which does not require the use of environmentally unacceptable fluids such as chlorofluorocarbons either as a dielectric or as a coolant, and which discharges very little waste heat into the surrounding air. A first magnetic switch has cooling channels formed therethrough to facilitate the removal of excess heat. The first magnetic switch is mounted on a printed circuit board. A pulse transformer comprised of a plurality of discrete electrically insulated and magnetically coupled units is also mounted on said printed board and is electrically coupled to the first magnetic switch. The pulse transformer also has cooling means attached thereto for removing heat from the pulse transformer. A second magnetic switch also having cooling means for removing excess heat is electrically coupled to the pulse transformer. Thus, the present invention is able to provide high voltage pulses of short duration at a high repetition rate and high peak power output without the use of environmentally unacceptable fluids and without discharging significant waste heat into the surrounding air.

Birx, Daniel L. (Oakley, CA); Arnold, Phillip A. (Livermore, CA); Ball, Don G. (Livermore, CA); Cook, Edward G. (Livermore, CA)

1995-01-01T23:59:59.000Z

176

Air and water cooled modulator  

DOE Patents [OSTI]

A compact high power magnetic compression apparatus and method are disclosed for delivering high voltage pulses of short duration at a high repetition rate and high peak power output which does not require the use of environmentally unacceptable fluids such as chlorofluorocarbons either as a dielectric or as a coolant, and which discharges very little waste heat into the surrounding air. A first magnetic switch has cooling channels formed therethrough to facilitate the removal of excess heat. The first magnetic switch is mounted on a printed circuit board. A pulse transformer comprised of a plurality of discrete electrically insulated and magnetically coupled units is also mounted on said printed board and is electrically coupled to the first magnetic switch. The pulse transformer also has cooling means attached thereto for removing heat from the pulse transformer. A second magnetic switch also having cooling means for removing excess heat is electrically coupled to the pulse transformer. Thus, the present invention is able to provide high voltage pulses of short duration at a high repetition rate and high peak power output without the use of environmentally unacceptable fluids and without discharging significant waste heat into the surrounding air. 9 figs.

Birx, D.L.; Arnold, P.A.; Ball, D.G.; Cook, E.G.

1995-09-05T23:59:59.000Z

177

Geochemical and geophysical responses during the infiltration of fresh water into the contaminated saprolite of the Oak Ridge Integrated  

E-Print Network [OSTI]

saprolite of the Oak Ridge Integrated Field Research Challenge site, Tennessee A. Revil,1,2 Y. Wu,3 M 2013; accepted 19 June 2013; published 12 August 2013. [1] At the Oak Ridge Integrated Field Research the infiltration of fresh water into the contaminated saprolite of the Oak Ridge Integrated Field Research

Hubbard, Susan

178

Ash melting behavior and slag infiltration into alumina refractory simulating co-gasification of coal and biomass  

Science Journals Connector (OSTI)

Abstract In the present study melting behavior of ashes from German brown coal and biomass (wheat straw) as well as from two artificial mixtures of both has been investigated. The four fuel samples were ashed at 450 °C over a period of 26 h. Ash fusion tests and all other measurements have been executed under reducing atmosphere, simulating gasification conditions. The ash melting and wetting properties have been studied for ash cylinders placed onto an alumina refractory at temperatures up to 1600 °C. Optical microscopy and SEM/EDX studies have been performed to analyze the infiltration of slag into the refractory and related progression. For the ash fusion behavior and surface wetting of the refractory clear distinctions from pure ashes have been detected for the blend with 50 wt.% biomass addition due to the formation of eutectics. From optical microscopy and SEM/EDX images of the sections different infiltration properties and mechanisms have been identified. The qualitative infiltration depth and deceleration of slag infiltration by a formation of solid phases have been provided by FactSage™ calculations. In these calculations the contact zone between the two materials has been reconstructed by a stepwise change in the amounts of ash and refractory. The experimental results are very well reflected in this model. Finally, the obtained results suggest low corrosive biomass amounts for co-use in the present gasifier types designed for pure coal.

Guanjun Zhang; Markus Reinmöller; Mathias Klinger; Bernd Meyer

2015-01-01T23:59:59.000Z

179

Microstructure and characteristics of the metalceramic composite (MgCa-HA/TCP) fabricated by liquid metal infiltration  

E-Print Network [OSTI]

in calcium phosphate bioceramics. Recently metal matrix composites (MMC), consisting of an adequate ceramicMicrostructure and characteristics of the metal­ceramic composite (MgCa-HA/TCP) fabricated and characteristics of the metal­ ceramic composite (MgCa-HA/TCP) fabricated by liquid metal infiltration. J Biomed

Zheng, Yufeng

180

Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles  

E-Print Network [OSTI]

Air Handling Unit Supply Air Temperature Optimization during Economizer Cycles Gang Wang, Zhan Wang, Ke Xu and Mingsheng Liu University of Nebraska – Lincoln Omaha, Nebraska, USA ABSTRACT Most air handling units (AHUs) in commercial...

Xu, K.; Liu, M.; Wang, G.; Wang, Z.

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Rates & Repayment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Environmental Review-NEPA Financial Data Operations Planning & Projects Power Marketing Rates Rate Adjustments Transmission Ancillary Services Rates WAPA-137 Rate Order Environmental Review-NEPA Financial Data Operations Planning & Projects Power Marketing Rates Rate Adjustments Transmission Ancillary Services Rates WAPA-137 Rate Order Rates and Repayment Services Rates Current and Historical Rate Information Collbran Power Rates CRSP Power Rates CRSP Transmission System Rates CRSP Management Center interest rates Falcon-Amistad Power Rates Provo River Power Rates Rio Grande Power Rates Seedskadee Power Rates SLCA/IP Power Rates Rate Schedules & Supplemental Rate Information Current Rates for Firm Power, Firm & Non-firm Transmission Service, & Ancillary Services Current Transmission & Ancillary Services Rates Tariffs Components of the SLCA/IP Existing Firm Power Rate Cost Recovery Charge (CRC) Page MOA Concerning the Upper Colorado River Basin

182

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers  

SciTech Connect (OSTI)

There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: closed and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percent age of the recirculation air is make-up air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both closed and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups: (1) Outside - coupons sheltered, located near or at the supply air inlet, but located before any filtering, (2) Supply - starting just after initial air filtering continuing inside the plenums and ducts feeding the data center rooms, and (3) Inside located inside the data center rooms near the IT equipment. Each coupon was exposed for thirty days and then sent to a laboratory for a corrosion rate measurement analysis. The goal of this research was to investigate whether gaseous contamination is a concern for U.S. data center operators as it relates to the reliability of IT equipment. More specifically, should there be an increased concern if outside air for IT equipment cooling is used To begin to answer this question limited exploratory measurements of corrosion rates in operating data centers in various locations were undertaken. This study sought to answer the following questions: (1) What is the precision of the measurements (2) What are the approximate statistical distributions of copper and silver corrosion rates in the sampled data centers(3) To what extent are copper and silver corrosion measurements related (4) What is the relationship of corrosion rate measurements between outside-air cooled data centers compared to closed data centers (5) How do corrosivity measurements relate to IT equipment failure rates The data from our limited sample size suggests that most United States data center operators should not be concerned with environmental gaseous contamination causing high IT equipment failure rates even when using outside-air cooling. The research team recommends additional basic research on how environmental conditions, specifically gaseous contamination, affect electronic equipment reliability.

Coles, Henry C.; Han, Taewon; Price, Phillip N.; Gadgil, Ashok J.; Tschudi, William F.

2011-07-17T23:59:59.000Z

183

Sources for Pu in near surface air  

SciTech Connect (OSTI)

This paper provides evidence that most of the Pu in the near surface air today is due to resuspension. Vertical and particle size distribution in near surface air over a period of three years were measured. The seasonal variations of Pu in air and the influence of meteorological parameters on these variations are shown. Samples were taken before the Chernobyl accident in an area where only Pu fallout from the atmospheric nuclear tests of the early sixties occurs. The comparison of the behavior of Pu with other trace elements, which were also measured, showed similar behavior of Pu and elements like Ca, Ti and Fe in near surface air. This confirms that most Pu is resuspended because the main source for these elements in air is the soil surface. Resuspension factors and resuspension rate are estimated for all measured elements. A resuspension factor of 0.8 X 10(-8) m-1 and a resuspension rate of 0.09 X 10(-9) s-1 is calculated for Pu.

Hartmann, G.; Thom, C.; Baechmann, K.

1989-01-01T23:59:59.000Z

184

Air ejector augmented compressed air energy storage system  

DOE Patents [OSTI]

Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air pressure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

1980-01-01T23:59:59.000Z

185

Abatement of Air Pollution: Prohibition of Air Pollution (Connecticut)  

Broader source: Energy.gov [DOE]

All air pollution not otherwise covered by these regulations is prohibited. Stationary sources which cause air pollution must be operated in accordance with all applicable emissions standards and...

186

Air transducers with high acoustic impedance  

Science Journals Connector (OSTI)

High?Z air transducers evolved from several industrial transducers. These predecessors include (a) acoustic emission and angle?beam NDT contact transducers; (b) flowmeter transducers for high?pressure methane hot refinery gases and corrosive flare gases; and (c) transducer arrays for monitoring hot corrosive gases flowing at Mach 0.1 in smokestacks of ?3–13 m. This peculiar ancestry accounts for their unusual high?acoustic?impedance construction. By not employing low?Z air?backed radiating membranes transducer bandwidth response time and sensitivity are sacrificed. The solid robust construction however offers some compensating features: tolerance to wide ranges in pressure and temperature including rapid rates of change (thermal shock depressurization); corrosion resistance; operable with standard lab equipment without bias voltage; mounting options where the transducer forms part of the pressure boundary or where it is outside the pressure boundary. Clamp?on air flow applications at one bar include small wind tunnels and plastic pipes. Acoustically isolated pairs measure secondary flow components (crossflow circulation) in a plane perpendicular to the pipe axis. Flow applications include gases such as air mild steam (pending) or other hot pressurized or corrosive fluids. Air?coupled measurements of transmission characteristics of wood or other low?density solids and air?ranging are readily demonstrated with the low?Z transducers.

Lawrence C. Lynnworth

1998-01-01T23:59:59.000Z

187

Air Pollution and Health Effects  

Science Journals Connector (OSTI)

The quality of the air we breathe is still a major concern to human health. Notwithstanding the air pollution mitigation efforts that have been pursued since ... be attributed to the effects of urban outdoor air

Ana Isabel Miranda; Joana Valente…

2014-01-01T23:59:59.000Z

188

Air Quality (Nova Scotia, Canada)  

Broader source: Energy.gov [DOE]

Nova Scotia Environment is responsible for monitoring the air quality in the province, as well as administering fines and permits relating to air quality. The Air Quality Regulations state...

189

Global air quality and climate  

E-Print Network [OSTI]

CRITICAL REVIEW Global air quality and climatewz Arlene M.determine regional air quality and can alter climate.to-continental scale air quality. Reducing the O 3 precursor

2012-01-01T23:59:59.000Z

190

Air heating system  

DOE Patents [OSTI]

A self-starting, fuel-fired, air heating system including a vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with the provision of heat exchanger and circuitry for cooling the condensed fluid output from the pump prior to its return to the vapor generator.

Primeau, John J. (19800 Seminole Rd., Euclid, OH 44117)

1983-03-01T23:59:59.000Z

191

E-Print Network 3.0 - air flow excitation Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

the upstream air pressure does not change the Mach number but does increase the mass flow rate through the wind... measurable penetration of helium ... Source: Buckley, Steven G. -...

192

Common Excess Air Trends in Industrial Boilers with Single-Point Positioning Control and Strategies to Optimize Efficiency  

E-Print Network [OSTI]

. This results in higher excess air levels at medium and low fire, yielding poorer efficiencies. Although boilers are potentially more efficient at reduced firing rates, high excess air levels limit their part-load efficiency air control in boilers and methods to quantify both boiler efficiency as a function of excess air

Kissock, Kelly

193

PROJECT TITLE: Evaluation of Seed and Fertilizer Opener Configurations for Optimizing Seed and Fertilizer Placement in Simultaneous, Single-Pass Operations with Air Drills under  

E-Print Network [OSTI]

to which crop root penetration is achieved. Root penetration measured after harvest for two air drill. These evaluations were conducted using the `Concord' air drill with seeding rate and overall fertilizer rate (70

Maxwell, Bruce D.

194

Maintaining System Air Quality | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Maintaining System Air Quality Maintaining System Air Quality This tip sheet discusses how to maintain air quality in compressed air systems through proper use of equipment....

195

Compressed Air Systems | Department of Energy  

Energy Savers [EERE]

Maintenance Strategies for Compressed Air Systems Remove Condensate with Minimal Air Loss Stabilizing System Pressure Compressed Air Training Compressed Air Systems Tools...

196

Compressed Air Storage Strategies | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Storage Strategies Compressed Air Storage Strategies This tip sheet briefly discusses compressed air storage strategies. COMPRESSED AIR TIP SHEET 9 Compressed Air Storage...

197

Air Quality Rules (North Carolina)  

Broader source: Energy.gov [DOE]

This is a comprehensive air quality rule for North Carolina that includes ambient air quality standards, emission control standards, monitoring and reporting requirements, and permitting procedures...

198

Ambient Air Quality Standards (Iowa)  

Broader source: Energy.gov [DOE]

These regulations set statewide ambient air quality standards for various contaminants. The state code follows the regulations set forth in the National Primary and Secondary Ambient Air Quality...

199

Padding with Compressed Air  

E-Print Network [OSTI]

We commonly find plants using padding to transport liquids or light solids short distances from tankers into storage tanks. Padding can wreck havoc in compressed air systems with limited storage, undersized cleanup equipment (dryers and filters...

Beals, C.

2004-01-01T23:59:59.000Z

200

Traffic air quality index  

Science Journals Connector (OSTI)

Abstract Vehicle emissions are responsible for a considerable share of urban air pollution concentrations. The traffic air quality index (TAQI) is proposed as a useful tool for evaluating air quality near roadways. The TAQI associates air quality with the equivalent emission from traffic sources and with street structure (roadway structure) as anthropogenic factors. The paper presents a method of determining the TAQI and defines the degrees of harmfulness of emitted pollution. It proposes a classification specifying a potential threat to human health based on the TAQI value and shows an example of calculating the TAQI value for real urban streets. It also considers the role that car traffic plays in creating a local UHI.

Zbigniew Bagie?ski

2015-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Ventilation Air Preconditioning Systems  

E-Print Network [OSTI]

Ventilation Air Preconditioning Systems Mukesh Khattar Michael J. Brandemuehl Manager, Space Conditioning and Refrigeration Associate Professor Customer Systems Group Joint Center for Energy Management Electric Power Research Institute Campus... costs, the small, modular nature of the system allows great flexibility for fitting into retrofit geometries and saves space in new construction. Moreover, a single chiller can serve multiple air-handling units-in stark contrast to packaged...

Khattar, M.; Brandemuehl, M. J.

1996-01-01T23:59:59.000Z

202

Integrated Technology Air Cleaners (ITAC): Design and Evaluation  

SciTech Connect (OSTI)

The primary objective of this project was to design, build, and test an air cleaner for residential use with the potential to substantially improve indoor air quality, or maintain indoor air quality unchanged, when outdoor air ventilation rates are reduced to save energy. Two air cleaners were designed and fabricated. The design targets for airflow rate, fan power, and projected cost were met. In short term laboratory studies, both units performed as expected; however, during field studies in homes, the formaldehyde removal performance of the air cleaners was much lower than expected. In subsequent laboratory studies, incomplete decomposition of some indoor air volatile organic compounds, with formaldehyde as a product of partial decomposition of volatile organic compounds, was confirmed as the explanation for the poor formaldehyde removal performance in the field studies. The amount of formaldehyde produced per unit of decomposition of other volatile organic compounds was substantially diminished by increasing the amount of catalyst on the filter and also by decreasing the air velocity. Together, these two measures reduced formaldehyde production, per unit destruction of other volatile organic compounds, by a factor of four, while increasing the removal efficiency of volatile organic compounds by a factor of 1.4. A company with a southern California office is conducting studies in conjunction with Lawrence Berkeley National Laboratory, with the goal of incorporating the ITAC catalytic air cleaning technology in their future commercial products.

Fisk, William J.; Cohn, Sebastian; Destaillats, Hugo; Henzel, Victor; Sidheswaran, Meera; Sullivan, Douglas P.

2013-09-13T23:59:59.000Z

203

Air Cooling | Open Energy Information  

Open Energy Info (EERE)

Cooling Cooling Jump to: navigation, search Dictionary.png Air Cooling: Air cooling is commonly defined as rejecting heat from an object by flowing air over the surface of the object, through means of convection. Air cooling requires that the air must be cooler than the object or surface from which it is expected to remove heat. This is due to the second law of thermodynamics, which states that heat will only move spontaneously from a hot reservoir (the heat sink) to a cold reservoir (the air). Other definitions:Wikipedia Reegle Air Cooling Air Cooling Diagram of Air Cooled Condenser designed by GEA Heat Exchangers Ltd. (http://www.gea-btt.com.cn/opencms/opencms/bttc/en/Products/Air_Cooled_Condenser.html) Air cooling is limited on ambient temperatures and typically require a

204

AIR SEALING Seal air leaks and save energy!  

E-Print Network [OSTI]

AIR SEALING Seal air leaks and save energy! W H A T I S A I R L E A K A G E ? Ventilation is fresh at stopping air leakage. It is critical to seal all holes and seams between these sheet goods with durable air that enters a house in a controlled manner to exhaust excess moisture and reduce odors

Oak Ridge National Laboratory

205

inAir: Sharing Indoor Air Quality Measurements and Visualizations  

E-Print Network [OSTI]

evidence has indicated that indoor air pollution within homes and other buildings can be worse than the outdoor air pollution in even the largest and most industrialized cities. For example, the California Air Resources Board estimates that indoor air pollutant levels are 25-62% greater than outside levels [4

Mankoff, Jennifer

206

Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference  

E-Print Network [OSTI]

permit regulations are designed to track, record, and control air pollutants belonging to severalAir Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference Department: Chemical on chemical classifications. This reference outlines major categories of air pollutants found at SLAC

Wechsler, Risa H.

207

Analysis of air leakage measurements of US houses  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Buildings 66 (2013) 616-625 Buildings 66 (2013) 616-625 Contents lists available at ScienceDirect Energy and Buildings j o u r n a l h o m e p a g e : w w w . e l s e v i e r . c o m / l o c a t e / e n b u i l d Analysis of air leakage measurements of US houses Wanyu R. Chan ∗ , Jeffrey Joh, Max H. Sherman Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory, One Cyclotron Road, Mailstop 90R3058, Berkeley, CA 94720, USA a r t i c l e i n f o Article history: Received 8 November 2012 Received in revised form 4 March 2013 Accepted 16 July 2013 Keywords: Blower door Fan pressurization test Normalized leakage Air infiltration Building envelope airtightness a b s t r a c t Building envelope airtightness is important for residential energy use, occupant health and comfort. We analyzed the air leakage measurements of 134,000 single-family detached homes in US, using normalized

208

A Survey: Indoor Air Quality in Schools  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3 3 A Survey: Indoor Air Quality in Schools We recently undertook a survey and critical review of the published literature on indoor air quality (IAQ), ventilation, and IAQ- and building-related health problems in schools, particularly those in the state of California. The survey's objectives included identifying the most commonly reported building-related health symptoms involving schools, and assembling and evaluating existing measurement data on key indoor air pollutants most likely to be related to these symptoms. The review also summarizes existing measurements of ventilation rates in schools and information on the causes of IAQ and health problems in schools. Most of the literature we reviewed (more than 450 articles and reports) dealt with complaint or problem schools. Among the papers were

209

PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED INTO A DWELLING  

E-Print Network [OSTI]

PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED.peuportier@mines-paristech.fr, Tel.: +33 1 40 51 91 51 ABSTRACT An inverter-driven air-to-air heat pump model has been developped capacity air-to-air heat pump coupled with temperate air sources (crawlspace, attic, sunspace, heat

Paris-Sud XI, Université de

210

Utility Rate Discount | Open Energy Information  

Open Energy Info (EERE)

Discount Discount Jump to: navigation, search A few electric utilities offer rate discounts to encourage residential energy efficiency. For homes that meet certain energy efficiency criteria, such as those established by the federal Energy Star program, the owner or tenant is awarded a percentage discount on each month’s electric bill. [1] Utility Rate Discount Incentives CSV (rows 1 - 14) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Cleco Power - Power Miser New Home Program (Louisiana) Utility Rate Discount Louisiana Residential Building Insulation Central Air conditioners Clothes Washers Comprehensive Measures/Whole Building Doors Duct/Air sealing Furnaces Heat pumps Water Heaters Windows Yes Dominion North Carolina Power - Energy Saver Home Plus (North Carolina) Utility Rate Discount North Carolina Residential Water Heaters

211

New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy ? FY11 Final Report  

SciTech Connect (OSTI)

The research carried out in this project focuses on developing novel volatile organic compounds (VOCs) air cleaning technologies needed to enable energy-saving reductions in ventilation rates. we targeted a VOC air cleaning system that could enable a 50% reduction in ventilation rates. In a typical commercial HVAC system that provides a mixture of recirculated and outdoor air, a VOC air cleaner in the supply airstream must have a 15% to 20% VOC removal efficiency to counteract a 50% reduction in outdoor air supply.

Sidheswaran, Meera; Destaillats, Hugo; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William J.

2011-10-31T23:59:59.000Z

212

EMISSIONS TO AIR OPERATIONAL PROCEDURE  

E-Print Network [OSTI]

EMISSIONS TO AIR OPERATIONAL PROCEDURE Swansea University Estates Services Singleton Park Swansea to Air Department: Estates and Facilities Site: All Author: Ambreen Jahangir Approved by: Mark Durdin PURPOSE: To minimise emissions and discharges to air from boilers, fume cupboards, air conditioning

Harman, Neal.A.

213

Air Quality | Open Energy Information  

Open Energy Info (EERE)

Retrieved from "http:en.openei.orgwindex.php?titleAirQuality&oldid612070" Category: NEPA Resources...

214

Development of a Web-Based, Emissions Reduction Calculator for Storm Water/Infiltration Sanitary Sewage Separation  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China 1 DEVELOPMENT OF A WEB-BASED, EMISSIONS REDUCTION CALCULATOR FOR STORM WATER/INFILTRATION SANITARY SEWAGE SEPARATION Zi Liu, Ph.D. Research Engineer Energy Systems Laboratory Charles Culp, Ph.D., P.... Professor Department of Civil Engineering Bahman Yazdani, P.E., CEM. Assc. Director Energy Systems Laboratory Texas A&M University ABSTRACT This paper presents the procedures developed to calculate the electricity savings and emissions...

Liu, Z.; Haberl, J. S.; Brumbelow, K.; Culp, C.; Gilman, D.; Yazdani, B.

2006-01-01T23:59:59.000Z

215

Compressed air energy storage system  

DOE Patents [OSTI]

An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

1981-01-01T23:59:59.000Z

216

Air Charter Services  

Broader source: Energy.gov (indexed) [DOE]

42.2 (April 2012) 42.2 (April 2012) 1 Documentation and Approval of Federally Funded International Travel (Fly America Act-Open Skies Agreement) Overview This section provides guidance to DOE Contracting Officers, Contracting Officer Representatives, and Program Officials on documentation and approval of federally funded international travel by Federal contractors and subcontractors in accordance with FAR 52.247-63 PREFERENCE FOR U.S.-FLAG AIR CARRIERS (JUNE 2003), 49 U.S.C. §40118 (Fly America Act) and the Open Skies Agreements as amended. Background Contracts that include FAR clause 52.247-63, PREFERENCE FOR U.S.-FLAG AIR CARRIERS (JUNE 2003) as prescribed in FAR 47.405 require that, if available, the Contractor (and subcontractors), in performing work under the contract, shall use U.S.-flag air carriers for

217

air_water.cdr  

Office of Legacy Management (LM)

12/2011 12/2011 Air Monitoring Groundwater Monitoring Surface Water Monitoring A continuously operating air monitoring network was in place from 1986 through 2000 for the Weldon Spring Site Remedial Action Project (WSSRAP) to measure levels of gamma radiation, radioactive dust particles, radon gas, and asbestos. With remediation of contaminated materials essentially complete and measurements indistinguishable from background, the U.S. Department of Energy (DOE) ceased perimeter and offsite air monitoring as of December 31, 2000. Groundwater has been routinely monitored at the site since 1986. Separate groundwater monitoring programs were established for the Chemical Plant and Quarry sites because of geographic separation and differences in the hydrogeologic features that influence

218

On the maximum pressure rise rate in boosted HCCI operation  

E-Print Network [OSTI]

This paper explores the combined effects of boosting, intake air temperature, trapped residual gas fraction, and dilution on the Maximum Pressure Rise Rate (MPRR) in a boosted single cylinder gasoline HCCI engine with ...

Wildman, Craig B.

219

Air-flow regulation system for a coal gasifier  

DOE Patents [OSTI]

An improved air-flow regulator for a fixed-bed coal gasifier is provided which allows close air-flow regulation from a compressor source even though the pressure variations are too rapid for a single primary control loop to respond. The improved system includes a primary controller to control a valve in the main (large) air supply line to regulate large slow changes in flow. A secondary controller is used to control a smaller, faster acting valve in a secondary (small) air supply line parallel to the main line valve to regulate rapid cyclic deviations in air flow. A low-pass filter with a time constant of from 20 to 50 seconds couples the output of the secondary controller to the input of the primary controller so that the primary controller only responds to slow changes in the air-flow rate, the faster, cyclic deviations in flow rate sensed and corrected by the secondary controller loop do not reach the primary controller due to the high frequency rejection provided by the filter. This control arrangement provides at least a factor of 5 improvement in air-flow regulation for a coal gasifier in which air is supplied by a reciprocating compressor through a surge tank.

Fasching, George E. (Morgantown, WV)

1984-01-01T23:59:59.000Z

220

E-Print Network 3.0 - acid combustion rate Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

air flows are established to provide local and overall... content, and the combustion gas heat loss rate. ... Source: Columbia University - Waste-to-Energy Research and Technology...

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

RADIONUCLIDE DISPERSION RATES BY AEOLIAN, FLUVIAL, AND POROUS MEDIA TRANSPORT  

SciTech Connect (OSTI)

Radionuclide transport was measured from high grade uranium ore boulders near the Nopal I Site, Chihuahua, Mexico. High grade uranium ore boulders were left behind after removal of a uranium ore stockpile at the Prior High Grade Stockpile (PHGS). During the 25 years when the boulder was present, radionuclides were released and transported by sheetflow during precipitation events, wind blown resuspension, and infiltration into the unsaturated zone. In this study, one of the boulders was removed, followed by grid sampling of the surrounding area. Measured gamma radiation levels in three dimensions were used to derive separate dispersion rates by the three transport mechanisms.

J. Walton; P. Goodell; C. Brashears; D. French; A. Kelts

2005-07-11T23:59:59.000Z

222

Ventilation System Effectiveness and Tested Indoor Air Quality Impacts  

SciTech Connect (OSTI)

Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

Rudd, A.; Bergey, D.

2014-02-01T23:59:59.000Z

223

Impacts of Mixing on Acceptable Indoor Air Quality in Homes  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Impacts of Mixing on Acceptable Indoor Air Quality in Homes Impacts of Mixing on Acceptable Indoor Air Quality in Homes Title Impacts of Mixing on Acceptable Indoor Air Quality in Homes Publication Type Journal Article LBNL Report Number LBNL-3048E Year of Publication 2010 Authors Sherman, Max H., and Iain S. Walker Journal HVAC & Research Journal Keywords air distribution, indoor air quality, mechanical ventilation, mixing, other, resave, residential ventilation, ventilation effectiveness Abstract Ventilation reduces occupant exposure to indoor contaminants by diluting or removing them. In a multi-zone environment such as a house, every zone will have different dilution rates and contaminant source strengths. The total ventilation rate is the most important factor in determining occupant exposure to given contaminant sources, but the zone-specific distribution of exhaust and supply air and the mixing of ventilation air can play significant roles. Different types of ventilation systems will provide different amounts of mixing depending on several factors such as air leakage, air distribution system, and contaminant source and occupant locations. Most U.S. and Canadian homes have central heating, ventilation, and air conditioning systems, which tend to mix the air; thus, the indoor air in different zones tends to be well mixed for significant fractions of the year. This article reports recent results of investigations to determine the impact of air mixing on exposures of residential occupants to prototypical contaminants of concern. We summarize existing literature and extend past analyses to determine the parameters than affect air mixing as well as the impacts of mixing on occupant exposure, and to draw conclusions that are relevant for standards development and for practitioners designing and installing home ventilation systems. The primary conclusion is that mixing will not substantially affect the mean indoor air quality across a broad population of occupants, homes, and ventilation systems, but it can reduce the number of occupants who are exposed to extreme pollutant levels. If the policy objective is to minimize the number of people exposed above a given pollutant threshold, some amount of mixing will be of net benefit even though it does not benefit average exposure. If the policy is to minimize exposure on average, then mixing air in homes is detrimental and should not be encouraged. We also conclude that most homes in the US have adequate mixing already, but that new, high-performance homes may require additional mixing. Also our results suggest that some differentiation should be made in policies and standards for systems that provide continuous exhaust, thereby reducing relative dose for occupants overall

224

Sticking with air  

SciTech Connect (OSTI)

A decision to replace more than 300 aging damper actuators at Independence Plant in Newark, Arkensas forced Entergy to make a choice between pneumatic and electric actuator designs. The dampers route air flow through separate dedicated compartments to ensure proper firing of pulverised coal. The reasons that pneumatics was chosen are discussed in this article. 4 figs.

Coker, S.N. [Entergy (US). Independence Plant

2005-06-01T23:59:59.000Z

225

The air plasma spraying  

Science Journals Connector (OSTI)

The air plasma spraying is characterized by using of a compressed air as a plasma forming gas. Here is shown the application of benefits of the present technology compared with other spraying process. The creation of the present process was possible due to a reliable plasma torch and certain condition of heating and deposition of powder materials on a work. Plasma torch develops a power up to 50 kW and can work during 14 hours without replacement of a cathode and during 25 hours as for an anode what is acceptable for industrial application. When spraying of coatings a minimum waste of alloying elements is attained with slight increase of oxygen in coating which is comparable with argon plasma spraying in the open. In certain cases the air plasma spraying allows to obtain more perfect coatings and at high performance. The present method finds large application at restoration and strengthening of machine parts, at forming of components etc. The air plasma spraying provides high quality coatings at low cost of components.

Valery S. Klubnikin

1993-01-01T23:59:59.000Z

226

Canned Air in China  

E-Print Network [OSTI]

Broadcast Transcript: Not that long ago, coal smoke made the air here in Beijing so caustic that your nasal passages were seared with each breath. Those were the good old days: Car ownership was limited to government officials and the rest...

Hacker, Randi

2013-10-23T23:59:59.000Z

227

Quantitative Imaging and Microlocalization of Boron-10 in Brain Tumors and Infiltrating Tumor Cells by SIMS Ion Microscopy: Relevance to Neutron Capture Therapy  

Science Journals Connector (OSTI)

...Imaging and Microlocalization of Boron-10 in Brain Tumors and Infiltrating...on the selective accumulation of boron-10 in tumor cells relative to the contiguous...evaluate the microdistribution of boron-10 from p-boronophenylalanine (BPA...

Duane R. Smith; Subhash Chandra; Rolf F. Barth; Weilian Yang; Darrel D. Joel; Jeffrey A. Coderre

2001-11-15T23:59:59.000Z

228

Chlorite Dissolution Rates  

SciTech Connect (OSTI)

Spreadsheets provides measured chlorite rate data from 100 to 300C at elevated CO2. Spreadsheet includes derived rate equation.

Carroll, Susan

2013-07-01T23:59:59.000Z

229

Chlorite Dissolution Rates  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Spreadsheets provides measured chlorite rate data from 100 to 300C at elevated CO2. Spreadsheet includes derived rate equation.

Carroll, Susan

230

Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics  

E-Print Network [OSTI]

Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

Graham, E. L.

1980-01-01T23:59:59.000Z

231

Compressed Air 101: Getting Compressed Air to Work  

E-Print Network [OSTI]

"Air compressors are a significant industrial energy user. Based on a survey (conducted by Oregon State University and the Bonneville Power Administration) of energy audit reports from 125 plants, air compressors account for roughly 10% of total...

Burke, J. J.; Bessey, E. G.

232

Vermont Air Pollution Control Regulations, Ambient Air Quality Standards (Vermont)  

Broader source: Energy.gov [DOE]

The ambient air quality standards are based on the national ambient air quality standards. The Vermont standards are classified as primary and secondary standards and judged adequate to protect...

233

Power Rate Cases (pbl/rates)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Choices (2003-06) Power Function Review (PFR) Firstgov Power Rate Cases BPA's wholesale power rates are set to recover its costs and repay the U.S. Treasury for the Federal...

234

Environmental Pollution Air Pollution Dispersion Practical Air Pollution Dispersion  

E-Print Network [OSTI]

Environmental Pollution Air Pollution Dispersion 1 of 5 Practical ­ Air Pollution Dispersion in the lectures how such models can be used to explain observed concentrations of air pollutants in an area and to test `what-if' scenarios for pollution control and reduction. You will use the Gaussian Plume Model

Moncrieff, John B.

235

Reducing Your Leak Rate Without Repairing Leaks  

E-Print Network [OSTI]

out of a thirteen-minute cycle, which meant they sat idle 76.9 percent of the time. We decided to divide the pneumatic circuit on each machine into two circuits, install an automatic solenoid valve, and program the PLC to shut the air off.... In this case, we decided to install an automatic solenoid valve at each position, and program the PLC to shut the air off to the position when it wasn?t operating. This reduced the leak rate by approximately 1100 scfm from 1500 scfm to 400 scfm. ...

Beals, C.

2005-01-01T23:59:59.000Z

236

Air Conditioning | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Conditioning Conditioning Air Conditioning July 1, 2012 - 6:28pm Addthis Air conditioners cost U.S. homeowners more than $11 billion each year, and regular maintenance can keep your air conditioner running efficiently. | Photo courtesy of ©iStockphoto/JaniceRichard Air conditioners cost U.S. homeowners more than $11 billion each year, and regular maintenance can keep your air conditioner running efficiently. | Photo courtesy of ©iStockphoto/JaniceRichard How does it work? An air conditioner uses energy -- usually electricity -- to transfer heat from the interior of your home to the relatively warm outside environment. Two-thirds of all homes in the United States have air conditioners. Air conditioners use about 5% of all the electricity produced in the United States, at an annual cost of more than $11 billion to homeowners. As a

237

Louisiana Air Control Law (Louisiana)  

Broader source: Energy.gov [DOE]

This law states regulations for air quality control and states the powers and duties of the secretary of environmental quality. It provides information about permits and licenses, air quality...

238

Air Pollution Indicator: PM10  

Science Journals Connector (OSTI)

As one of natural elements, clean air is essential to human beings’ survival. ... , almost all economic and social activities emit air pollutants, especially such sectors as power and ... and international commun...

Hezhong Tian; Yimeng Liu

2014-01-01T23:59:59.000Z

239

Air Liquide- Biogas & Fuel Cells  

Broader source: Energy.gov [DOE]

Presentation about Air Liquide's biogas technologies and integration with fuel cells. Presented by Charlie Anderson, Air Liquide, at the NREL/DOE Biogas and Fuel Cells Workshop held June 11-13, 2012, in Golden, Colorado.

240

Solar Heating and Air Conditioning  

Science Journals Connector (OSTI)

...given of the status of solar fired air conditioning...to an approach to cool storage in solar air conditioning systems...an assessment of cool storage for reducing peak electrical...rolling cylinder thermal energy storage device for compact...

1980-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Compressed Air Audits using AIRMaster  

E-Print Network [OSTI]

Air compressors are a significant industrial energy user and therefore a prime target for industrial energy audits. The project goal was to develop a software tool, AIRMaster, and supporting methodology for performing compressed air system audits...

Wheeler, G. M.; McGill, R. D.; Bessey, E. G.; Vischer, K.

242

Fundamentals of Compressed Air Systems  

Broader source: Energy.gov [DOE]

Find out how a compressed air system works and the benefits of optimal compressed air system performance. This initial class demonstrates how to compute the current cost of your plant's compressed...

243

Roadway tunnel air quality models  

Science Journals Connector (OSTI)

Roadway tunnel air quality models ... Analysis of 13 tunnel studies quantifies the decline since 1961 in benzo[a]pyrene emitted into the air per km of travel by U.S. road vehicles. ...

Tai Y. Chang; Sara J. Rudy

1990-05-01T23:59:59.000Z

244

Simulation of air and mist drilling for geothermal wells  

SciTech Connect (OSTI)

An improved method for calculating downhole temperatures, pressures, fluid densities and velocities during air drilling has been developed. The basic equations of fluid flow for a gas with cuttings and mist are presented along with a numerical method for their solution. Several applications of this calculational method are given, showing the effect of flow rate and standpipe pressures in typical air and mist drilling situations. 8 refs.

Mitchell, R.F.

1981-01-01T23:59:59.000Z

245

Compressed Air System Control Strategies  

Broader source: Energy.gov [DOE]

This tip sheet briefly discusses compressed air system control strategies as a means to improving and maintaining system performance.

246

Compressed Air Energy Storage System  

E-Print Network [OSTI]

/expanders are crucial for the economical viability of a Compressed Air Energy Storage (CAES) system such as the

Farzad A. Shirazi; Mohsen Saadat; Bo Yan; Perry Y. Li; Terry W. Simon

247

Analyzing Your Compressed Air System  

Broader source: Energy.gov [DOE]

This tip sheet outlines the process to analyze industrial compressed air systems and ensure proper system configuration.

248

Air Leaks in Unexpected Places  

Broader source: Energy.gov [DOE]

Sealing air leaks will help to decrease heating and cooling costs and make your home more comfortable.

249

AIR QUALITY REPORT SPARKS CONTROVERSY  

Science Journals Connector (OSTI)

AIR QUALITY REPORT SPARKS CONTROVERSY ... The National Commission on Air Quality delivered its eagerly awaited report to Congress today, and reaction from industry and environmental groups is expected to be both swift and sharp. ... Created under the 1977 Clean Air Act, the commission was charged with assessing the effectiveness of the law, and recommending changes where the law falls short of achieving the goal of improving the nation's air quality. ...

1981-03-02T23:59:59.000Z

250

Air-Lift design theory  

Science Journals Connector (OSTI)

1. Employing graphical relationships between height of lift of the emulsion, depth of shaft, and specific air ra...

P. R. Khlopenkov

1970-10-01T23:59:59.000Z

251

The Viscosity of Air  

Science Journals Connector (OSTI)

The viscosity of air has been remeasured with the rotating cylinder apparatus used by Day and Bleakney. All of the constants have been redetermined, and especial attention has been given to the corrections to the simple theory. The value obtained at 22°C is ?=1.8243±0.0045 c.g.s. units. This raises the oil drop value of e to 4.796 e.s.u. It is shown in the appendix that a correction must be applied for the opening between the suspended cylinder and the guard cylinders, and also a correction must be applied for the moment of inertia of the air carried around by the cylinder when determining its moment of inertia. Neglect of these corrections has introduced some additional uncertainty into other work.

W. V. Houston

1937-10-01T23:59:59.000Z

252

FLUIDIC: Metal Air Recharged  

SciTech Connect (OSTI)

Fluidic, with the help of ARPA-E funding, has developed and deployed the world's first proven high cycle life metal air battery. Metal air technology, often used in smaller scale devices like hearing aids, has the lowest cost per electron of any rechargeable battery storage in existence. Deploying these batteries for grid reliability is competitive with pumped hydro installations while having the advantages of a small footprint. Fluidic's battery technology allows utilities and other end users to store intermittent energy generated from solar and wind, as well as maintain reliable electrical delivery during power outages. The batteries are manufactured in the US and currently deployed to customers in emerging markets for cell tower reliability. As they continue to add customers, they've gained experience and real world data that will soon be leveraged for US grid reliability.

Friesen, Cody

2014-03-07T23:59:59.000Z

253

FLUIDIC: Metal Air Recharged  

ScienceCinema (OSTI)

Fluidic, with the help of ARPA-E funding, has developed and deployed the world's first proven high cycle life metal air battery. Metal air technology, often used in smaller scale devices like hearing aids, has the lowest cost per electron of any rechargeable battery storage in existence. Deploying these batteries for grid reliability is competitive with pumped hydro installations while having the advantages of a small footprint. Fluidic's battery technology allows utilities and other end users to store intermittent energy generated from solar and wind, as well as maintain reliable electrical delivery during power outages. The batteries are manufactured in the US and currently deployed to customers in emerging markets for cell tower reliability. As they continue to add customers, they've gained experience and real world data that will soon be leveraged for US grid reliability.

Friesen, Cody

2014-04-02T23:59:59.000Z

254

Air Pollution & Health in Rapidly Developing Countries  

E-Print Network [OSTI]

For example, “Air Pollution and Health – Studies in theAssessment of Air Pollution and Health” is illustrative inReview: Air Pollution & Health in Rapidly Developing

Bucher, Scott

2005-01-01T23:59:59.000Z

255

California Air Resources Board | Open Energy Information  

Open Energy Info (EERE)

Air Resources Board Jump to: navigation, search Logo: California Air Resources Board Name: California Air Resources Board Place: Sacramento, California Website: http:...

256

113 air quality control station [n  

Science Journals Connector (OSTI)

envir. (Facility for measurement of air pollution; ? air quality network/system );s estación [f] de medición de la calidad del aire (? red de ev...

2010-01-01T23:59:59.000Z

257

ORIGINAL ARTICLE Ambient Air Pollution  

E-Print Network [OSTI]

supporting an association between am- bient air pollution and cardiovascular health, much re- mains health effects of ambient air pollution in Atlanta being undertaken by this Emory investi- gative teamORIGINAL ARTICLE Ambient Air Pollution and Cardiovascular Emergency Department Visits Kristi Busico

Mulholland, James A.

258

PROPOSED RESEARCH AGENDA FOR ACHIEVING INDOOR AIR QUALITY SUPPORTING HEALTH AND  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

PROPOSED RESEARCH AGENDA FOR ACHIEVING PROPOSED RESEARCH AGENDA FOR ACHIEVING INDOOR AIR QUALITY SUPPORTING HEALTH AND COMFORT IN HIGHLY ENERGY EFFICIENT BUILDINGS Pawel Wargocki 1* , Max Sherman 2 , Willem de Gids 3 , Peter Wouters 4 , Francis Allard 5 , Remi Carrie 6 , Paolo Carrer 7 , and Stylianos Kephalopolous 8 1 International Centre for Indoor Environment and Energy, DTU Civil Engineering, Technical University of Denmark 2 Residential Building Systems Group, Lawrence Berkeley National Laboratory, USA 3 VentGuide, the Netherlands 4 Air Infiltration and Ventilation Centre, Belgium 5 University of La Rochelle, France 6 International Network for Information on Ventilation, Belgium 7 The University of Milan, Italy 8 Joint Research Centre, Ispra, Italy ABSTRACT Research topics that need to be addressed so that the future highly energy efficient buildings do not compromise

259

Air Pollution Control Regulations: No. 22 - Air Toxics (Rhode Island) |  

Broader source: Energy.gov (indexed) [DOE]

Air Pollution Control Regulations: No. 22 - Air Toxics (Rhode Air Pollution Control Regulations: No. 22 - Air Toxics (Rhode Island) Air Pollution Control Regulations: No. 22 - Air Toxics (Rhode Island) < Back Eligibility Commercial Industrial Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Program Info State Rhode Island Program Type Siting and Permitting Provider Department of Environmental Management Permits are required to construct, install, or modify any stationary source which has the potential to increase emissions of a listed toxic air contaminant by an amount greater than the minimum quantity for that contaminant. Minimum quantities are specified in Table III of these regulations. Permits will be granted based in part on the impact of the projected emissions of the stationary source on acceptable ambient levels

260

Cooling energy efficiency and classroom air environment of a school building operated by the heat recovery air conditioning unit  

Science Journals Connector (OSTI)

Abstract The recently-built school buildings have adopted novel heat recovery ventilator and air conditioning system. Heat recovery efficiency of the heat recovery facility and energy conservation ratio of the air conditioning unit were analytically modeled, taking the ventilation networks into account. Following that, school classroom displacement ventilation and its thermal stratification and indoor air quality indicated by the CO2 concentration have been numerically modeled concerning the effects of delivering ventilation flow rate and supplying air temperature. Numerical results indicate that the promotion of mechanical ventilation rate can simultaneously boost the dilution of indoor air pollutants and the non-uniformity of indoor thermal and pollutant distributions. Subsequent energy performance analysis demonstrates that classroom energy demands for ventilation and cooling could be reduced with the promotion of heat recovery efficiency of the ventilation facility, and the energy conservation ratio of the air conditioning unit decreases with the increasing temperatures of supplying air. Fitting correlations of heat recovery ventilation and cooling energy conservation have been presented.

Yang Wang; Fu-Yun Zhao; Jens Kuckelkorn; Di Liu; Li-Qun Liu; Xiao-Chuan Pan

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Air Risk Information Support Center  

SciTech Connect (OSTI)

The Air Risk Information Support Center (Air RISC) was initiated in early 1988 by the US Environmental Protection Agency`s (EPA) Office of Health and Environmental Assessment (OHEA) and the Office of Air Quality Planning and Standards (OAQPS) as a technology transfer effort that would focus on providing information to state and local environmental agencies and to EPA Regional Offices in the areas of health, risk, and exposure assessment for toxic air pollutants. Technical information is fostered and disseminated by Air RISCs three primary activities: (1) a {open_quotes}hotline{close_quotes}, (2) quick turn-around technical assistance projects, and (3) general technical guidance projects. 1 ref., 2 figs.

Shoaf, C.R.; Guth, D.J. [Environmental Protection Agency, Washington, DC (United States)

1990-12-31T23:59:59.000Z

262

Laboratory Performance Testing of Residential Window Air Conditioners  

SciTech Connect (OSTI)

Window air conditioners are the dominant cooling product for residences, in terms of annual unit sales. They are inexpensive, portable and can be installed by the owner. For this reason, they are an attractive solution for supplemental cooling, for retrofitting air conditioning into a home which lacks ductwork, and for renters. Window air conditioners for sale in the United States are required to meet very modest minimum efficiency standards. Four window air conditioners' performance were tested in the Advanced HVAC Systems Laboratory on NREL's campus in Golden, CO. In order to separate and study the refrigerant system's performance, the unit's internal leakage pathways, the unit's fanforced ventilation, and the leakage around the unit resulting from installation in a window, a series of tests were devised that focused on each aspect of the unit's performance. These tests were designed to develop a detailed performance map to determine whole-house performance in different climates. Even though the test regimen deviated thoroughly from the industry-standard ratings test, the results permit simple calculation of an estimated rating for both capacity and efficiency that would result from a standard ratings test. Using this calculation method, it was found that the three new air conditioners' measured performance was consistent with their ratings. This method also permits calculation of equivalent SEER for the test articles. Performance datasets were developed across a broad range of indoor and outdoor operating conditions, and used them to generate performance maps.

Winkler, J.; Booten, C.; Christensen, D.; Tomerlin, J.

2013-03-01T23:59:59.000Z

263

Low-friction coatings for air bearings in fuel cell air compressors  

SciTech Connect (OSTI)

In an effort to reduce fuel consumption and emissions, hybrid vehicles incorporating fuel cell systems are being developed by automotive manufacturers, their suppliers, federal agencies (specifically, the US Department of Energy) and national laboratories. The fuel cell system will require an air management subsystem that includes a compressor/expander. Certain components in the compressor will require innovative lubrication technology in order to reduce parasitic energy losses and improve their reliability and durability. One such component is the air bearing for air turbocompressors designed and fabricated by Meruit, Inc. Argonne National Laboratory recently developed a carbon-based coating with low friction and wear attributes; this near-frictionless-carbon (NFC) coating is a potential candidate for use in turbocompressor air bearings. The authors present here an evaluation of the Argonne coating for air compressor thrust bearings. With two parallel 440C stainless steel discs in unidirectional sliding contact, the NFC reduced the frictional force four times and the wear rate by more than two orders of magnitude. Wear mechanism on the uncoated surface involved oxidation and production of iron oxide debris. Wear occurred on the coated surfaces primarily by a polishing mechanism.

Ajayi, O. O.; Fenske, G. R.; Erdemir, A.; Woodford, J.; Sitts, J.; Elshot, K.; Griffey, K.

2000-01-06T23:59:59.000Z

264

Urban and Regional Air Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

equipment equipment Urban and Regional Air Quality Research in this area is concerned with regional air quality issues such as: Controlling nitrogen oxides (NOx) and volatile organic compounds, to manage tropospheric ozone pollution. Hazardous air pollutants: using science to base standards on rigorously studied risks. Air quality and climate: how does climate influence air quality at a regional or local level? Current modeling practices often do not capture variations in pollutants such as ozone-they represent a limited sample of the diverse meteorology and human behavior that affect air pollution. Improved modeling of regional air quality will help understand variability, reveal patterns of behavior, and pollutant transport issues. Controlled experiments in lab and field can help validate improved models.

265

Control of water infiltration into near surface LLW (low level waste) disposal units: Annual report, October 1985-September 1986  

SciTech Connect (OSTI)

In the humid eastern part of the United States, trench covers have, in general, failed to prevent some of the incident precipitation from percolating downward to buried wastes. It is the purpose of the present work to investigate and demonstrate a procedure or technique that will control water infiltration to buried wastes regardless of above or below ground disposal. Results to date show the proposed procedure to be very promising and are applicable to shallow land burial as well as above ground disposal (e.g., Tumulus). In essence, the technique combines engineered or positive control of run-off, along with a vegetative cover, and is named ''bioengineering management''. To investigate control of infiltration, lysimeters are being used to make complete water balance measurements. The studies have been underway at the Maxey Flats, Kentucky, low-level waste disposal facility for the past three seasonal years. When the original Maxey Flats site closure procedure is followed, it is necessary to pump large amounts of water out of the lysimeters to prevent the water table from rising closer than 2 meters from the surface. Using the bioengineering management procedure, no pumping is required. As a result of the encouraging initial findings in the rather small-scale lysimeters at Maxey Flats, a large-scale facility for demonstration of the bioengineering management technique has been constructed at Beltsville, Maryland. This facility is now operational with the demonstration and data collection underway. 6 refs., 15 figs.

Schulz, R.K.; Ridky, R.W.; O'Donnell, E.

1987-04-01T23:59:59.000Z

266

Infiltrating a thin or single layer opal with an atomic vapour: sub-doppler signals and crystal optics  

E-Print Network [OSTI]

Artificial thin glass opals can be infiltrated with a resonant alkali-metal vapour, providing novel types of hybrid systems. The reflection at the interface between the substrate and the opal yields a resonant signal, which exhibits sub-Doppler structures in linear spectroscopy for a range of oblique incidences. This result is suspected to originate in an effect of the three-dimensional confinement of the vapour in the opal interstices. It is here extended to a situation where the opal is limited to a few or even a single layer opal film, which is a kind of bidimensional grating. We have developed a flexible one-dimensional layered optical model, well suited for a Langmuir-Blodgett opal. Once extended to the case of a resonant infiltration, the model reproduces quick variations of the lineshape with incidence angle or polarization. Alternately, for an opal limited to a single layer of identical spheres, a three-dimensional numerical calculation was developed. It predicts crystalline anisotropy, which is demon...

Moufarej, Elias; Zabkov, Ilya; Laliotis, Athanasios; Ballin, Philippe; Klimov, Vasily; Bloch, Daniel

2014-01-01T23:59:59.000Z

267

Clean Air Act | Department of Energy  

Office of Environmental Management (EM)

Clean Air Act Clean Air Act The primary law governing the Department of Energy (DOE) air pollution control activities is the Clean Air Act (CAA). This law defines the role of the...

268

Measurement Methods to Determine Air Leakage Between Adjacent Zones  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Measurement Methods to Determine Air Leakage Between Adjacent Zones Measurement Methods to Determine Air Leakage Between Adjacent Zones Title Measurement Methods to Determine Air Leakage Between Adjacent Zones Publication Type Report LBNL Report Number LBNL-5887E Year of Publication 2012 Authors Hult, Erin L., Darryl J. Dickerhoff, and Phillip N. Price Date Published 09/2012 Keywords infiltration, leakage, residential ventilation Abstract Air leakage between adjacent zones of a building can lead to indoor air quality and energy efficiency concerns, however there is no existing standard for measuring inter-zonal leakage.In this study, synthesized data and field measurements are analyzed in order to explore the uncertainty associated with different methods for collecting and analyzing fan pressurization measurements to calculate inter- zone leakage. The best of the measurement and analysis methods was a method that uses two blower doors simultaneously based on the methods of Herrlin and Modera (1988) to determine the inter-zone leakage to within 16% of the inter-zone leakage flow at 4Pa, over the range of expected conditions for a house and attached garage. Methods were also identified that use a single blower door to determine the inter-zone leakage to within 30% of its value. The test configuration selected can have a large impact on the uncertainty of the results and there are testing configurations and methods that should definitely be avoided. The most rigorous calculation method identified assumes a fixed value for the pressure exponent for the interface between the two zones (rather than determining the interface pressure exponent from the measured data) and then uses an optimization routine to fit a single set of air leakage coefficients and pressure exponents for each of three wall interfaces using both pressurization and depressurization data. Multiple pressure station tests have much less uncertainty than single pressure station approaches. Analyses of field data sets confirm a similar level of variation between test methods as was expected from the analysis of synthesized data sets and confirm the selection of specific test methods to reduce experimental uncertainty.

269

An automobile air conditioner design model  

SciTech Connect (OSTI)

A computer program has been developed to predict the steady-state performance of vapor compression automobile air conditioners and heat pumps. The code is based on the residential heat pump model developed at the Oak Ridge National Laboratory (ORNL). Most calculations are based on fundamental physical principles, in conjunction with generalized correlations available in the research literature. Automobile air conditioning components that can be specified as input to the program include open and hermetic compressors; finned tube condensers; finned tube and plate-fin style evaporators; thermostatic expansion valves (TXV), capillary tube, and short tube expansion devices; refrigerant mass; and evaporator pressure regulator and all interconnecting tubing. Pressure drop, heat transfer rates, and latent capacity ratio for the new plate-fin evaporator submodel are shown to agree well with laboratory data. The program can be used with a variety of refrigerants, including R-134a.

Kyle, D M; Mei, V C; Chen, F C

1992-12-01T23:59:59.000Z

270

Fine and Ultrafine Particle Decay Rates in Multiple Homes  

Science Journals Connector (OSTI)

All homes exchange indoor air with outdoor air at a certain base rate dependent on the construction quality of the home and on indoor–outdoor temperature and pressure differences. ... A number of multiple-home studies have measured indoor particle concentrations, but few have been able to determine the rates of particle removal for individual homes under normal living conditions. ... Therefore continuous measurements from this study of FP and UFP in 74 homes in Edmonton Canada were analyzed to determine these rates of removal in each home during week-long measurement periods in summer and winter. ...

Lance Wallace; Warren Kindzierski; Jill Kearney; Morgan MacNeill; Marie-Ève Héroux; Amanda J. Wheeler

2013-10-21T23:59:59.000Z

271

Electrocatalysts for Nonaqueous Lithium–Air Batteries:...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Electrocatalysts for Nonaqueous Lithium–Air Batteries: Status, Challenges, and Perspective. Electrocatalysts for Nonaqueous Lithium–Air Batteries: Status, Challenges,...

272

Remove Condensate with Minimal Air Loss  

Broader source: Energy.gov [DOE]

This tip sheet outlines several condensate removal methods as part of maintaining compressed air system air quality.

273

Safeguarding indoor air quality  

SciTech Connect (OSTI)

California has created and implemented the first state program devoted exclusively to the investigation of nonindustrial indoor air quality. The program is responsible for promoting and conducting research on the determining factors of healthful indoor environments and is structured to obtain information about emission sources, ventilation effects, indoor concentrations, human activity patterns, exposures, health risks, control measures and public policy options. Data are gathered by a variety of methods, including research conducted by staff members, review of the available scientific literature, participation in technical meetings, contractual agreements with outside agencies, cooperative research projects with other groups and consultation with experts. 23 references, 1 figure, 1 table.

Sexton, K.; Wesolowski, J.J.

1985-01-01T23:59:59.000Z

274

STUDY OF FROST GROWTH ON HEAT EXCHANGERS USED AS OUTDOOR COILS IN AIR SOURCE HEAT PUMP SYSTEMS  

E-Print Network [OSTI]

STUDY OF FROST GROWTH ON HEAT EXCHANGERS USED AS OUTDOOR COILS IN AIR SOURCE HEAT PUMP SYSTEMS OF FROST GROWTH ON HEAT EXCHANGERS USED AS OUTDOOR COILS IN AIR SOURCE HEAT PUMP SYSTEMS Dissertation . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 3.5.3 Air Side Heat Transfer Rates . . . . . . . . . . . . . . . . . . 43 3.5.4 Fluid Side Heat

275

Abatement of Air Pollution: Hazardous Air Pollutants (Connecticut)  

Broader source: Energy.gov [DOE]

These regulations describe maximum allowable stack concentrations and hazard limiting values for the emission of hazardous air pollutants. The regulations also discuss sampling procedures for...

276

Exploring the consequences of climate change for indoor air quality  

Science Journals Connector (OSTI)

Climate change will affect the concentrations of air pollutants in buildings. The resulting shifts in human exposure may influence public health. Changes can be anticipated because of altered outdoor pollution and also owing to changes in buildings effected in response to changing climate. Three classes of factors govern indoor pollutant levels in occupied spaces: (a) properties of pollutants; (b) building factors, such as the ventilation rate; and (c) occupant behavior. Diversity of indoor conditions influences the public health significance of climate change. Potentially vulnerable subpopulations include not only the young and the infirm but also those who lack resources to respond effectively to changing conditions. Indoor air pollutant levels reflect the sum of contributions from indoor sources and from outdoor pollutants that enter with ventilation air. Pollutant classes with important indoor sources include the byproducts of combustion, radon, and volatile and semivolatile organic compounds. Outdoor pollutants of special concern include particulate matter and ozone. To ensure good indoor air quality it is important first to avoid high indoor emission rates for all pollutants and second to ensure adequate ventilation. A third factor is the use of air filtration or air cleaning to achieve further improvements where warranted.

William W Nazaroff

2013-01-01T23:59:59.000Z

277

System and method for determining an ammonia generation rate in a three-way catalyst  

SciTech Connect (OSTI)

A system according to the principles of the present disclosure includes a rate determination module, a storage level determination module, and an air/fuel ratio control module. The rate determination module determines an ammonia generation rate in a three-way catalyst based on a reaction efficiency and a reactant level. The storage level determination module determines an ammonia storage level in a selective catalytic reduction (SCR) catalyst positioned downstream from the three-way catalyst based on the ammonia generation rate. The air/fuel ratio control module controls an air/fuel ratio of an engine based on the ammonia storage level.

Sun, Min; Perry, Kevin L; Kim, Chang H

2014-12-30T23:59:59.000Z

278

Engineering analysis and economic impacts of air pollution abatement strategies for cotton gins  

E-Print Network [OSTI]

conveying rate of 1. 9 m'/kg (30 fr'/Ib). Seed cotton entering the ginning system will typically have a higher moisture content. 9. All the other fan systems will have a conveying rate of at least 1. 6 m'/kg (25 ft'/lb). 10. Since bash fans convey only... about 385 kg (850 lb) of material, the air flow was likely to be underestimated if a 1. 6 m'/kg (25 fr'/lb) conveying rate is used. Hence, the amount of air flow for trash fans was found after estimating all the rest of the process air flows...

Ramaiyer, Anantharaman

2012-06-07T23:59:59.000Z

279

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE  

Broader source: Energy.gov (indexed) [DOE]

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing October 6, 2010 - 10:08am Addthis DOE testing in support of the ENERGY STAR program has revealed that an Electrolux Gibson air conditioner (model GAH105Q2T1) and an Equator clothes washer (model EZ 3720 CEE), both of which claimed ENERGY STAR ratings, do not meet the ENERGY STAR requirements. Specifically, the test results for the Electrolux Gibson model show that, when tested in accordance with DOE's test procedures, it consumed 6.1 percent more energy than the Energy Star requirement. Test results for the Equator model show that it exceeds Energy Star's water factor requirements by 12.3 percent.

280

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE  

Broader source: Energy.gov (indexed) [DOE]

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing October 6, 2010 - 10:08am Addthis DOE testing in support of the ENERGY STAR program has revealed that an Electrolux Gibson air conditioner (model GAH105Q2T1) and an Equator clothes washer (model EZ 3720 CEE), both of which claimed ENERGY STAR ratings, do not meet the ENERGY STAR requirements. Specifically, the test results for the Electrolux Gibson model show that, when tested in accordance with DOE's test procedures, it consumed 6.1 percent more energy than the Energy Star requirement. Test results for the Equator model show that it exceeds Energy Star's water factor requirements by 12.3 percent.

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Air Liquide - Biogas & Fuel Cells  

Broader source: Energy.gov (indexed) [DOE]

Liquide - Biogas & Fuel Cells Hydrogen Energy Biogas Upgrading Technology 12 June 2012 Charlie.Anderson@airliquide.com 2 Air Liquide, world leader in gases for industry,...

282

Nebraska Air Quality Regulations (Nebraska)  

Broader source: Energy.gov [DOE]

These regulations, promulgated by the Department of Environmental Quality, contain provisions pertaining to ambient air quality standards, pollution source operating permits, emissions reporting,...

283

Global air quality and climate  

E-Print Network [OSTI]

Chemistry and Climate Model Intercomparison Project (ACCMIP;of chemistry–climate models with RCP emissions thus projectto project air quality responses to future climate change

2012-01-01T23:59:59.000Z

284

Air Force Renewable Energy Programs  

Broader source: Energy.gov [DOE]

Presentation covers Air Force Renewable Energy Programs and is given at the Spring 2011 Federal Utility Partnership Working Group (FUPWG) meeting.

285

High temperature electrochemical corrosion rate probes for combustion environments  

SciTech Connect (OSTI)

Electrochemical corrosion rate probes have been constructed and tested along with mass loss coupons in an air plus water vapor and a N2/O2/CO2 plus water vapor environment. Temperatures ranged from 200? to 700?C. Results show that electrochemical corrosion rates for ash-covered mild steel are a function of time, temperature and process environment. Correlation between the electrochemical and mass loss corrosion rates was poor.

Covino, Bernard S., Jr.; Bullard, Sophie J.; Cramer, Stephen D.; Holcomb, Gordon R.; Ziomek-Moroz, Margaret; Eden, David A. (Intercorr International Inc.); Kane, Russell D. (Intercorr International Inc.); Eden, Dawn C. (Intercorr International Inc.)

2004-01-01T23:59:59.000Z

286

Reactive Air Aluminization  

SciTech Connect (OSTI)

Ferritic stainless steels and other alloys are of great interest to SOFC developers for applications such as interconnects, cell frames, and balance of plant components. While these alloys offer significant advantages (e.g., low material and manufacturing cost, high thermal conductivity, and high temperature oxidation resistance), there are challenges which can hinder their utilization in SOFC systems; these challenges include Cr volatility and reactivity with glass seals. To overcome these challenges, protective coatings and surface treatments for the alloys are under development. In particular, aluminization of alloy surfaces offers the potential for mitigating both evaporation of Cr from the alloy surface and reaction of alloy constituents with glass seals. Commercial aluminization processes are available to SOFC developers, but they tend to be costly due to their use of exotic raw materials and/or processing conditions. As an alternative, PNNL has developed Reactive Air Aluminization (RAA), which offers a low-cost, simpler alternative to conventional aluminization methods.

Choi, Jung-Pyung; Chou, Y. S.; Stevenson, Jeffry W.

2011-10-28T23:59:59.000Z

287

rates | OpenEI  

Open Energy Info (EERE)

rates rates Dataset Summary Description This dataset, compiled by NREL and Ventyx, provides average residential, commercial and industrial electricity rates by zip code for both investor owned utilities (IOU) and non-investor owned utilities. Note: the file includes average rates for each utility, but not the detailed rate structure data found in the database available via the zip-code look-up feature on the OpenEI Utilities page (http://en.openei.org/wiki/Gateway:Utilities). The data was released by NREL/Ventyx in February 2011. Source NREL and Ventyx Date Released February 24th, 2012 (2 years ago) Date Updated Unknown Keywords electric rates rates US utilities Data text/csv icon IOU rates by zipcode (csv, 1.7 MiB) text/csv icon Non-IOU rates by zipcode (csv, 2.1 MiB)

288

Laser sheet light flow visualization for evaluating room air flowsfrom Registers  

SciTech Connect (OSTI)

Forced air heating and cooling systems and whole house ventilation systems deliver air to individual rooms in a house via supply registers located on walls ceilings or floors; and occasionally less straightforward locations like toe-kicks below cabinets. Ideally, the air velocity out of the registers combined with the turbulence of the flow, vectoring of air by register vanes and geometry of register placement combine to mix the supply air within the room. A particular issue that has been raised recently is the performance of multiple capacity and air flow HVAC systems. These systems vary the air flow rate through the distribution system depending on the system load, or if operating in a ventilation rather than a space conditioning mode. These systems have been developed to maximize equipment efficiency, however, the high efficiency ratings do not include any room mixing effects. At lower air flow rates, there is the possibility that room air will be poorly mixed, leading to thermal stratification and reduced comfort for occupants. This can lead to increased energy use as the occupants adjust the thermostat settings to compensate and parts of the conditioned space have higher envelope temperature differences than for the well mixed case. In addition, lack of comfort can be a barrier to market acceptance of these higher efficiency systems To investigate the effect on room mixing of reduced air flow rates requires the measurement of mixing of supply air with room air throughout the space to be conditioned. This is a particularly difficult exercise if we want to determine the transient performance of the space conditioning system. Full scale experiments can be done in special test chambers, but the spatial resolution required to fully examine the mixing problem is usually limited by the sheer number of thermal sensors required. Current full-scale laboratory testing is therefore severely limited in its resolution. As an alternative, we used a water-filled scale model of a room in which whole-field supply air mixing maps of two vertical planes were measured using a Planar Laser-Induced Fluorescence (PLIF) measurement technique. Water marked with fluorescent dye was used to simulate the supply airflow; and the resulting concentrations within the water filled model show how the supply air mixes with the room air and are an analog for temperature (for thermal loads) or fresh air (for ventilation). In addition to performing experiments over a range of flow rates, we also changed register locations and examined the effects for both heating and cooling operation by changing the water density (simulating air density changes due to temperature changes) using dissolved salt.

Walker, Iain S.; Claret, Valerie; Smith, Brian

2006-04-01T23:59:59.000Z

289

Reply to "Commentary: Assessment of past infiltration fluxes through Yucca Mountain on the basis of the secondary mineral record-is it a viable methodology?", by Y.V. Dublyansky and S.Z. Smirnov  

E-Print Network [OSTI]

infiltration fluxes through Yucca Mountain on the basis ofdata for the unsaturated zone at Yucca Mountain (Nevada).AMR U0085, Yucca Mountain Nuclear Waste Disposal Project,

Sonnenthal, Eric; Xu, Tianfu; Bodvarrson, Gudmundur

2005-01-01T23:59:59.000Z

290

Control of water infiltration into near surface low-level waste disposal units. Final report on field experiments at a humid region site, Beltsville, Maryland  

SciTech Connect (OSTI)

This study`s objective was to assess means for controlling water infiltration through waste disposal unit covers in humid regions. Experimental work was carried out in large-scale lysimeters 21.34 m x 13.72 m x 3.05 m (70 ft x 45 ft x 10 ft) at Beltsville, Maryland. Results of the assessment are applicable to disposal of low-level radioactive waste (LLW), uranium mill tailings, hazardous waste, and sanitary landfills. Three kinds of waste disposal unit covers or barriers to water infiltration were investigated: (1) resistive layer barrier, (2) conductive layer barrier, and (3) bioengineering management.

Schulz, R.K.; Ridky, R.W.; O`Donnell, E.

1997-09-01T23:59:59.000Z

291

Thermal efficiency of single-pass solar air collector  

SciTech Connect (OSTI)

Efficiency of a finned single-pass solar air collector was studied. This paper presents the experimental study to investigate the effect of solar radiation and mass flow rate on efficiency. The fins attached at the back of absorbing plate to improve the thermal efficiency of the system. The results show that the efficiency is increased proportional to solar radiation and mass flow rate. Efficiency of the collector archived steady state when reach to certain value or can be said the maximum performance.

Ibrahim, Zamry; Ibarahim, Zahari; Yatim, Baharudin [School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor Darul Ehsan (Malaysia); Ruslan, Mohd Hafidz [Solar Energy Research Institute (SERI), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor Darul Ehsan (Malaysia)

2013-11-27T23:59:59.000Z

292

An air line carries air at 800 kPa and 80C. An Air line ~ O O C insulated tank initially contains 20C air at a  

E-Print Network [OSTI]

An air line carries air at 800 kPa and 80°C. An Air line ~ O O C insulated tank initially contains 20°C air at a pressure of 90kPa. The valve is opened, and air flows into the tank. Determine the final temperature of the air in the tank and the mass of air that enters the tank if the valve is left

Huang, Haimei

293

Heat balance for two commercial broiler barns with solar preheated ventilation air  

Science Journals Connector (OSTI)

In temperate climatic zones, solar air heaters can reduce heating loads, and increase winter ventilation rates thereby improving inside air quality and livestock performance without additional fuel input. A heat balance was carried out to measure bird heat production under field conditions on two commercial broiler barns to evaluate the impact of solar heated ventilation air on bird performance, and identify strategies to reduce winter heating load. Located 40 km east of Montreal, Canada, the experimental broiler barns were identically built with three floors housing 6500 birds per floor in an all-in all-out fashion. Equipped with solar air pre-heaters over their fresh air inlets, the barns were instrumented to monitor inlet, inside and outside air conditions, ventilation rate and heating system operating time. The effects on bird performance were observed from November 2007 to March 2009 by alternating their operation between the barns. The measured sensible and total heat productions of 4.5 W and 8.4 W, respectively, for 1 kg birds corresponded to laboratory measured values. Bird performance was not affected by the solar air pre-heaters which increased the ventilation rate above normal during only 20% of the daytime period. Room air temperature stratification resulted in 20–40 kW of heat losses during the winter, representing 25% of the total natural gas heat load. Because inside air moved directly to the fans, large and rapid increases in ventilation inlet air temperature, produced by the solar air pre-heaters, resulted in further heat losses equivalent to 15% of the solar energy recovered. Sustainable energy management in livestock barns requiring heating should incorporate an air mixing system to eliminate air temperature stratification and improve fan flows.

Sébastien Cordeau; Suzelle Barrington

2010-01-01T23:59:59.000Z

294

Air Leakage of US Homes: Regression Analysis and Improvements from Retrofit  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Leakage of US Homes: Regression Analysis and Improvements from Retrofit Leakage of US Homes: Regression Analysis and Improvements from Retrofit Title Air Leakage of US Homes: Regression Analysis and Improvements from Retrofit Publication Type Report LBNL Report Number LBNL-5966E Year of Publication 2012 Authors Chan, Wanyu R., Jeffrey Joh, and Max H. Sherman Date Published 08/2012 Keywords air infiltration, blower door, fan pressurization measurements, retrofit, weatherization Abstract LBNL Residential Diagnostics Database (ResDB) contains blower door measurements and other diagnostic test results of homes in United States. Of these, approximately 134,000 single-family detached homes have sufficient information for the analysis of air leakage in relation to a number of housing characteristics. We performed regression analysis to consider the correlation between normalized leakage and a number of explanatory variables: IECC climate zone, floor area, height, year built, foundation type, duct location, and other characteristics. The regression model explains 68% of the observed variability in normalized leakage. ResDB also contains the before and after retrofit air leakage measurements of approximately 23,000 homes that participated in weatherization assistant programs (WAPs) or residential energy efficiency programs. The two types of programs achieve rather similar reductions in normalized leakage: 30% for WAPs and 20% for other energy programs.

295

Measure Guideline: Combustion Safety for Natural Draft Appliances Using Indoor Air  

SciTech Connect (OSTI)

This measure guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate measure guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

Brand, L.

2014-04-01T23:59:59.000Z

296

Historical Interest Rates  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Current and Historical Interest Rates Current and Historical Interest Rates The table lists interest rates, from the project's inception through the present, for all projects with repayment supervised by the CRSP MC. The latest available interest rate is used for all future interest rate calculations. The Amistad-Falcon, Collbran, Provo River, and Rio Grande Projects are all assigned the average daily "Yield Rate" calculated by the U.S. Treasury, on an annual basis, for Treasury bonds having terms of 15 years or more remaining to maturity. The calculated yield rate is rounded to the nearest one-eighth of one percent. The yield rate is based upon the bond's interest rate, as well as its market value. The Colorado River Storage Project and its participating projects, Dolores and Seedskadee, are assigned the average daily "Coupon Rate," annualized for the same U.S. Treasury bonds used in "Yield Rate" calculations. The coupon rate is the interest rate that the bond carries upon its face.

297

Inhalation intake of ambient air pollution in California's South Coast Air Basin  

E-Print Network [OSTI]

the impacts on air pollution and health of urban areaas a proxy for air pollution health effects (Bennett etFuel combustion, air pollution exposure, and health: The

Marshall, Julian D.; Granvold, Patrick W.; Hoats, Abigail S.; McKone, Thomas E.; Deakin, Elizabeth; Nazaroff, William W.

2006-01-01T23:59:59.000Z

298

Biomass Control in Waste Air Biotrickling Filters by Protozoan Predation  

E-Print Network [OSTI]

Biomass Control in Waste Air Biotrickling Filters by Protozoan Predation Huub H. J. Cox, Marc A as a means of biomass control. Wet biomass for- mation in 23.6-L reactors over a 77-day period was reduced in the biotrickling filter enriched with protozoa. The lower rate of biomass accumulation after the addi- tion

299

Retrofitting Air Conditioning and Duct Systems in Hot, Dry Climates  

SciTech Connect (OSTI)

This technical report describes CARB's work with Clark County Community Resources Division in Las Vegas, Nevada, to optimize procedures for upgrading cooling systems on existing homes in the area to implement health, safety, and energy improvements. Detailed monitoring of five AC systems showed that three of the five systems met or exceeded air flow rate goals.

Shapiro, C.; Aldrich, R.; Arena, L.

2012-07-01T23:59:59.000Z

300

Cost Analysis Rate Settin  

E-Print Network [OSTI]

Cost Analysis and Rate Settin for Animal Research Facilities #12;#12;Cost Analysis and Rate ... .. . ...................... . . . ................................. . .... 7 Chapter 2 Preparation for Cost Analysis ......................................................... 9 Chapter 3 Assignment of Costs to Animal Research Facility Cost Centers

Baker, Chris I.

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Switching Surges and Air Insulation  

Science Journals Connector (OSTI)

...research-article Switching Surges and Air Insulation B. Jones Some thirteen years ago...reduction was noticed in the strength of air insulation when subjected to slowly rising positive...collected in high voltage laboratories. Insulation against switching surges is now seen...

1973-01-01T23:59:59.000Z

302

Protective supplied breathing air garment  

DOE Patents [OSTI]

A breathing air garment for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap.

Childers, Edward L. (Lakewood, CO); von Hortenau, Erik F. (Golden, CO)

1984-07-10T23:59:59.000Z

303

Protective supplied breathing air garment  

DOE Patents [OSTI]

A breathing air garment is disclosed for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap. 17 figs.

Childers, E.L.; Hortenau, E.F. von.

1984-07-10T23:59:59.000Z

304

Definition: Dynamic Capability Rating System | Open Energy Information  

Open Energy Info (EERE)

Capability Rating System Capability Rating System Jump to: navigation, search Dictionary.png Dynamic Capability Rating System Dynamic capability rating adjusts the thermal rating of power equipment based on factors such as air temperature, wind speed, and solar radiation to reflect actual operating conditions. These systems are primarily used on high capacity or critical power system elements such as transmission lines and large power transformers.[1] Related Terms transmission lines, Dynamic capability rating, thermal rating, power, solar radiation, rating, transmission line, transformer References ↑ https://www.smartgrid.gov/category/technology/dynamic_capability_rating_system [[Category LikeLike UnlikeLike You like this.Sign Up to see what your friends like. : Smart Grid Definitions|Template:BASEPAGENAME]]

305

Proceedings: Indoor Air 2005 REACTIONS BETWEEN OZONE AND BUILDING PRODUCTS: IMPACT ON  

E-Print Network [OSTI]

Proceedings: Indoor Air 2005 2118 REACTIONS BETWEEN OZONE AND BUILDING PRODUCTS: IMPACT ON PRIMARY of reactions of ozone on building products and on their emissions in indoor air. For this purpose, 12 building products were exposed to ozone in a dedicated experimental setup. The measured ozone removal rate

Paris-Sud XI, Université de

306

High Efficiency Particulate Air Filters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

High Efficiency Particulate Air (HEPA) Filters High Efficiency Particulate Air (HEPA) Filters Home Standards DOE Workshops Nuclear Air Cleaning Conference Proceedings Qualified Filter List News Items Related Sites HEPA Related Lessons Learned Contact Us HSS Logo High Efficiency Particulate Air Filters The HEPA Filter web site provides a forum for informing and reporting department-wide activities related to filtration and ventilation issues with special reference to the High Efficiency Particulate Air (HEPA) Filters' use, inspection, and testing. This site contains essentials of DOE HEPA filter test program, procedures, requirements and quality assurance aspects applicable to HEPA filters used in DOE facilities. This site contains information about the DOE-accepted Filter Test Facility and its management, operation and quality assuranceprogram.

307

NETL: IEP - Air Quality Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Home > Technologies > Coal & Power Systems > Innovations for Existing Plants > Air Quality Research Home > Technologies > Coal & Power Systems > Innovations for Existing Plants > Air Quality Research Innovations for Existing Plants Air Quality Research Ambient Monitoring Emissions Characterization Predictive Modeling & Evaluation Health Effects Regulatory Drivers Air Quality Research Reference Shelf The NETL Air Quality Research program is designed to resolve the scientific uncertainties associated with the atmospheric formation, distribution, and chemical transformation of pollutant emissions from today's coal-fired power plants, and to obtain a realistic assessment of the human health impacts of these emissions. Results of this research will help the DOE Office of Fossil Energy address policy questions regarding coal plant emissions and provide guidance for future emissions control R&D programs at

308

air conditioner | OpenEI  

Open Energy Info (EERE)

air conditioner air conditioner Dataset Summary Description View 2010 energy efficiency data from AeroSys Inc, Coaire, Cold Point, First Operations, LG Electronics, Nordyne, and Quietside manufacturers. Data includes cooling capacity, cooling performance, heating capacity, and heating performance. Spreadsheet was created by combining the tables in pdf files that are included in the zip file. Source Energy Applicance Data - United States Federal Trade Commission, www.ftc.gov Date Released Unknown Date Updated Unknown Keywords air conditioner central air conditioner efficiency efficient energy heat pump Data application/vnd.ms-excel icon 2010_CentralAC_All.xls (xls, 82.4 KiB) application/zip icon 2010CentralAirConditioner.zip (zip, 398.2 KiB) Quality Metrics Level of Review Some Review

309

Air Force Renewable Energy Programs  

Broader source: Energy.gov (indexed) [DOE]

1 1 Ken Gray P.E. HQ AFCESA /CENR Air Force Renewable Energy Programs April, 2011 FUPWG "Make Energy a Consideration in All We Do" I n t e g r i t y - S e r v i c e - E x c e l l e n c e THINK GREEN, BUILD GREEN, Topics  Air Force Energy Use  Air Force Facility Energy Center  Current RE Generation  Project Development System  Programmed RE Generation FY11-13  Goal Achievement 2 I n t e g r i t y - S e r v i c e - E x c e l l e n c e THINK GREEN, BUILD GREEN, Air Force 2010 Energy Use The Air Force spent approximately $8.2 billion for energy in 2010; an increase of 22% from 2009 Energy Cost and Consumption Trends Energy Cost Breakdown Aviation 79% Facilities 17% 3 Aviation 84% Facilities 12% Vehicles & Equipment

310

Air Leakage and Air Transfer Between Garage and Living Space  

SciTech Connect (OSTI)

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

Rudd, A.

2014-09-01T23:59:59.000Z

311

Vermont Air Pollution Control Regulations, Major Stationary Sources and Major Modifications (Vermont)  

Broader source: Energy.gov [DOE]

This section of the air quality standards applies to all major sources and major modifications and outlines the required control technology to achieve the most stringent emission rate. Emission...

312

E-Print Network 3.0 - air methane vam Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Reagents Methane (99.99 v.%, Air Products and Chemicals, Inc.) and propane (99.0 v.%, Praxair) were used... of carbon catalyst activation on the rate of methane decomposition...

313

E-Print Network 3.0 - air cooled slagging Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

to fouling from slag and fly ash deposition. Slagging... of steam. In creased boiler size is associated with increased air flow, fuel, and ash transport rates which... of fuel...

314

Quantitative Imaging and Microlocalization of Boron-10 in Brain Tumors and Infiltrating Tumor Cells by SIMS Ion Microscopy: Relevance to Neutron Capture Therapy  

Science Journals Connector (OSTI)

...Tumors and Infiltrating Tumor Cells by SIMS Ion MicroscopyRelevance to Neutron Capture...of boron delivery agents. However, the SIMS-based technique of ion microscopy (14...these analytes are strong indicators that SIMS matrix effects 8 are minimal and that the...

Duane R. Smith; Subhash Chandra; Rolf F. Barth; Weilian Yang; Darrel D. Joel; Jeffrey A. Coderre

2001-11-15T23:59:59.000Z

315

Use of Personal-Indoor-Outdoor Sulfur Concentrations to Estimate the Infiltration Factor and Outdoor Exposure Factor for Individual Homes and Persons  

Science Journals Connector (OSTI)

Use of Personal-Indoor-Outdoor Sulfur Concentrations to Estimate the Infiltration Factor and Outdoor Exposure Factor for Individual Homes and Persons ... Indoor?outdoor comparisons of sulfur concentrations thus provide a direct way to estimate Finf for each individual home. ... Of 36 homes, 22 had intercepts not significantly different from zero, indicating no apparent source of sulfur in the home. ...

Lance Wallace; Ron Williams

2005-01-26T23:59:59.000Z

316

Quantification of Lower Extremity Muscle Fat Infiltration in Pediatric Patients with Spina Bifida using Water-Fat MRI Houchun Harry Hu1  

E-Print Network [OSTI]

Quantification of Lower Extremity Muscle Fat Infiltration in Pediatric Patients with Spina Bifida , Vicente Gilsanz1 , and Tishya A. L. Wren3 1 Radiology, Children's Hospital Los Angeles, Los Angeles. Methods ­ Five pediatric patients with spina bifida (3F, 2M, age: 13.4±1.0 years, all Hispanic) were

Southern California, University of

317

Analysis of a Dedicated Outdoor Air System and Low Temperature Supply Air Conditioning System  

E-Print Network [OSTI]

This paper presents the principles and the characteristics of a dedicated outdoor air system (DOAS) and low temperature supply air system. DOAS is offered based on the demands of indoor air quality and the low temperature supply air system...

Guang, L.; Li, R.

2006-01-01T23:59:59.000Z

318

Dynamic modeling of an integrated air-to-air heat pump using Modelica  

Science Journals Connector (OSTI)

Heat pump systems have gained significant market shares in Europe recently. The control strategy is an asset for the efficient operation of these thermodynamic systems; especially with compact integrated components. The predictive control, which allows fast system stabilization, is based on the description of the system physical behavior. Thus, dynamic modeling is needed for the development of such control. The model has to represent the system response to usual external perturbations met during current operation such as the variation of air temperature and air mass flow rate. The aim of this paper is to present a dynamic model of a thermodynamic system developed in the Dymola environment, which is an object-oriented modeling environment. The heat-pump components are created separately as individual objects, and then connected to form the system. The model of each component is described and the responses to different perturbations are detailed. Simulation results are compared to test results in order to validate the model.

S. Mortada; A. Zoughaib; D. Clodic; C. Arzano-Daurelle

2012-01-01T23:59:59.000Z

319

Supply Fan Control for Constant Air Volume Air Handling Units  

E-Print Network [OSTI]

Since terminal boxes do not have a modulation damper in constant volume (CV) air handling unit (AHU) systems, zone reheat coils have to be modulated to maintain the space temperature with constant supply airflow. This conventional control sequence...

Cho, Y.; Wang, G.; Liu, M.

2007-01-01T23:59:59.000Z

320

2011 Air Quality Regulations Report | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air Quality Regulations Report 2011 Air Quality Regulations Report 2011 Air Quality Regulations Report120111.pdf More Documents & Publications 2011:...

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Evaluation of a Combined Ultraviolet Photocatalytic Oxidation(UVPCO)/Chemisorbent Air Cleaner for Indoor Air Applications  

SciTech Connect (OSTI)

We previously reported that gas-phase byproducts of incomplete oxidation were generated when a prototype ultraviolet photocatalytic oxidation (UVPCO) air cleaner was operated in the laboratory with indoor-relevant mixtures of VOCs at realistic concentrations. Under these conditions, there was net production of formaldehyde and acetaldehyde, two important indoor air toxicants. Here, we further explore the issue of byproduct generation. Using the same UVPCO air cleaner, we conducted experiments to identify common VOCs that lead to the production of formaldehyde and acetaldehyde and to quantify their production rates. We sought to reduce the production of formaldehyde and acetaldehyde to acceptable levels by employing different chemisorbent scrubbers downstream of the UVPCO device. Additionally, we made preliminary measurements to estimate the capacity and expected lifetime of the chemisorbent media. For most experiments, the system was operated at 680-780 m{sup 3}/h (400-460 cfm). A set of experiments was conducted with common VOCs introduced into the UVPCO device individually and in mixture. Compound conversion efficiencies and the production of formaldehyde and acetaldehyde were determined by comparison of compound concentrations upstream and downstream of the reactor. There was general agreement between compound conversions efficiencies determined individually and in the mixture. This suggests that competition among compounds for active sites on the photocatalyst surface will not limit the performance of the UVPCO device when the total VOC concentration is low. A possible exception was the very volatile alcohols, for which there were some indications of competitive adsorption. The results also showed that formaldehyde was produced from many commonly encountered VOCs, while acetaldehyde was generated by specific VOCs, particularly ethanol. The implication is that formaldehyde concentrations are likely to increase when an effective UVPCO air cleaner is used in buildings containing typical VOC sources. The magnitude of the expected increase will depend upon a number of interrelated factors. Series of experiments were conducted to determine if the oxidizer, sodium permanganate (NaMnO{sub 4}{center_dot}H{sub 2}O), has sufficient reaction rates and capacity to counteract formaldehyde and acetaldehyde production and enable a 50 % reduction in building ventilation rate without net increases in indoor aldehyde concentrations. A commercially produced filter element and two laboratory-fabricated media beds containing NaMnO{sub 4}{center_dot}H{sub 2}O chemisorbent media were evaluated. The effectiveness of a device for removal of formaldehyde, acetaldehyde and other VOCs was determined by measurement of concentrations immediately upstream and downstream of the device. In some experiments, conversion efficiencies and byproduct generation by the UVPCO device also were determined. Six experiments were conducted with the commercial filter element installed downstream of the UVPCO reactor. Eleven experiments were conducted with a single panel media bed (30 cm by 61 cm by 2.5 cm deep) installed downstream of the UVPCO reactor; in these, the effects of temperature and air residence time on conversion efficiency were examined. Two experiments were conducted with a four-panel, folded, media bed (approximately four times the size of the single panel bed) installed downstream of the reactor. Because the commercial unit contained activated carbon as an additional component, it was effective at removing lower volatility compounds that typically have low oxidation rates in the UVPCO reactor. The filter element also met the minimum efficiency objective for formaldehyde. However, the removal of acetaldehyde was less than required. The air residence time in the single panel bed was not optimized as the removal efficiencies for both formaldehyde and acetaldehyde were strongly inversely related to the air flow rate through the device. In addition, the acetaldehyde removal efficiency decreased to less than 10% with extended use of the device. The fold

Hodgson, Alfred T.; Destaillats, Hugo; Hotchi, Toshifumi; Fisk,William J.

2007-02-01T23:59:59.000Z

322

Activation of Air and Utilities in the National Ignition Facility  

SciTech Connect (OSTI)

Detailed 3-D modeling of the NIF facility is developed to accurately simulate the radiation environment within the NIF. Neutrons streaming outside the NIF Target Chamber will activate the air present inside the Target Bay and the Ar gas inside the laser tubes. Smaller levels of activity are also generated in the Switchyard air and in the Ar portion of the SY laser beam path. The impact of neutron activation of utilities located inside the Target Bay is analyzed for variety of shot types. The impact of activating TB utilities on dose received by maintenance personnel post-shot is analyzed. The current NIF facility model includes all important features of the Target Chamber, shielding system, and building configuration. Flow of activated air from the Target Bay is controlled by the HVAC system. The amount of activated Target Bay air released through the stack is very small and does not pose significant hazard to personnel or the environment. Activation of Switchyard air is negligible. Activation of Target Bay utilities result in a manageable dose rate environment post high yield (20 MJ) shots. The levels of activation generated in air and utilities during D-D and THD shots are small and do not impact work planning post shots.

Khater, H; Pohl, B; Brererton, S

2010-04-08T23:59:59.000Z

323

Central Air Conditioning | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Central Air Conditioning Central Air Conditioning Central Air Conditioning May 30, 2012 - 8:01pm Addthis Central air conditioners circulate cool air through a system of supply and return ducts. | Photo courtesy of ©iStockphoto/DonNichols. Central air conditioners circulate cool air through a system of supply and return ducts. | Photo courtesy of ©iStockphoto/DonNichols. What does this mean for me? Central air conditioning systems are thermostatically controlled and convenient to use. Central air conditioning systems must be installed properly to operate efficiently. Central air conditioning systems can share ductwork with your heating system. Central air conditioners circulate cool air through a system of supply and return ducts. Supply ducts and registers (i.e., openings in the walls,

324

Tips: Sealing Air Leaks | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Sealing Air Leaks Sealing Air Leaks Tips: Sealing Air Leaks May 16, 2013 - 5:03pm Addthis Sources of Air Leaks in Your Home. Areas that leak air into and out of your home cost you a lot of money. The areas listed in the illustration are the most common sources of air leaks. Sources of Air Leaks in Your Home. Areas that leak air into and out of your home cost you a lot of money. The areas listed in the illustration are the most common sources of air leaks. Air leaks can waste a lot of your energy dollars. One of the quickest energy-- and money-saving tasks you can do is caulk, seal, and weather strip all seams, cracks, and openings to the outside. Tips for Sealing Air Leaks Test your home for air tightness. On a windy day, carefully hold a lit incense stick or a smoke pen next to your windows, doors, electrical

325

Tips: Sealing Air Leaks | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tips: Sealing Air Leaks Tips: Sealing Air Leaks Tips: Sealing Air Leaks May 16, 2013 - 5:03pm Addthis Sources of Air Leaks in Your Home. Areas that leak air into and out of your home cost you a lot of money. The areas listed in the illustration are the most common sources of air leaks. Sources of Air Leaks in Your Home. Areas that leak air into and out of your home cost you a lot of money. The areas listed in the illustration are the most common sources of air leaks. Air leaks can waste a lot of your energy dollars. One of the quickest energy-- and money-saving tasks you can do is caulk, seal, and weather strip all seams, cracks, and openings to the outside. Tips for Sealing Air Leaks Test your home for air tightness. On a windy day, carefully hold a lit incense stick or a smoke pen next to your windows, doors, electrical

326

Room Air Conditioners | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Room Air Conditioners Room Air Conditioners Room Air Conditioners July 1, 2012 - 5:35pm Addthis A window air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/kschulze. A window air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/kschulze. What does this mean for me? Room air conditioners are less expensive and disruptive to install than central air conditioning systems. Room air conditioners can be a cost-effective alternative to central air conditioning systems. How does it work? Room air conditioners work by cooling one part of your home. Room or window air conditioners cool rooms rather than the entire home or business. If they provide cooling only where they're needed, room air conditioners are less expensive to operate than central units, even though

327

Air Pollution and Epigenetics: Recent Findings  

Science Journals Connector (OSTI)

The health effects of ambient air pollution are well-described, but less is known ... , microRNA, and DNA methylation; along with air pollutant keywords: air pollution, benzo[a]pyrene, nitrogen dioxide, ozone...1

Carrie V. Breton; Amy N. Marutani

2014-03-01T23:59:59.000Z

328

DunoAir | Open Energy Information  

Open Energy Info (EERE)

DunoAir Jump to: navigation, search Name: DunoAir Place: Hessen, Germany Zip: 6865 VX Sector: Wind energy Product: Doorwerth-based wind project developer. References: DunoAir1...

329

Inertial impaction air sampling device  

DOE Patents [OSTI]

An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

Dewhurst, K.H.

1987-12-10T23:59:59.000Z

330

ENVITEC shows off air technologies  

SciTech Connect (OSTI)

The ENVITEC International Trade Fair for Environmental Protection and Waste Management Technologies, held in June in Duesseldorf, Germany, is the largest air pollution exhibition in the world and may be the largest environmental technology show overall. Visitors saw thousands of environmental solutions from 1,318 companies representing 29 countries and occupying roughly 43,000 square meters of exhibit space. Many innovations were displayed under the category, ``thermal treatment of air pollutants.`` New technologies include the following: regenerative thermal oxidizers; wet systems for removing pollutants; biological scrubbers;electrostatic precipitators; selective adsorption systems; activated-coke adsorbers; optimization of scrubber systems; and air pollution monitors.

McIlvaine, R.W.

1995-08-01T23:59:59.000Z

331

Inertial impaction air sampling device  

DOE Patents [OSTI]

An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry.

Dewhurst, Katharine H. (13150 Wenonah SE. Apt. 727, Albuquerque, NM 87123)

1990-01-01T23:59:59.000Z

332

Inertial impaction air sampling device  

DOE Patents [OSTI]

An inertial impactor is designed which is to be used in an air sampling device for collection of respirable size particles in ambient air. The device may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

Dewhurst, K.H.

1990-05-22T23:59:59.000Z

333

Air pollution kills. So what? Air quality engineering to improve public health  

E-Print Network [OSTI]

9/14/12 1 Air pollution kills. So what? Air quality engineering to improve public health;9/14/12 5 Health benefits from reducing PM2.5 "Each 10 µg m-3 elevation in fine particle air pollution;9/14/12 2 Air Quality Engineering H Air Quality Engineering H #12;9/14/12 3 Really? Air pollution

Levinson, David M.

334

WearAir: Expressive T-shirts for Air Quality Sensing Sunyoung Kim and Eric Paulos  

E-Print Network [OSTI]

are less proactively concerned with air quality. AIR POLLUTANT: VOLATILE ORGANIC COMPOUNDS Different types of air pollutants contribute to air quality in different locations: Ozone, CO, NOx and VOCs are major contributors to outdoor air pollution; and particulate matters, VOCs, carbon monoxide and lead are common air

Mankoff, Jennifer

335

Degradation characteristics of air cathode in zinc air fuel cells  

Science Journals Connector (OSTI)

Abstract The zinc air fuel cell (ZAFC) is a promising candidate for electrical energy storage and electric vehicle propulsion. However, its limited durability has become a major obstacle for its successful commercialization. In this study, 2-cell stacks, 25 cm² cells and three-electrode half-cells are constructed to experimentally investigate the degradation characteristics of the air cathode. The results of electrochemical tests reveal that the peak power density for the 25 cm2 cell with a new air cathode is 454 mW cm?2, which is twice as the value of the used air cathode. The electrochemical impedance analysis shows that both the charge transfer resistance and the mass transfer resistance of the used air cathodes have increased, suggesting that the catalyst surface area and gas diffusion coefficient have decreased significantly. Additionally, the microstructure and morphology of the catalytic layer (CL) and gas diffusion layer (GDL) are characterized by scanning electron microscopes (SEM). SEM results confirm that the micropores in CL and GDL of the used air cathode are seriously clogged, and many catalyst particles are lost. Therefore, the performance degradation is mainly due to the clogging of micropores and loss of catalyst particles. Furthermore, hypotheses of degradation mechanism and mitigation strategies for GDL and CL are discussed briefly.

Ze Ma; Pucheng Pei; Keliang Wang; Xizhong Wang; Huachi Xu; Yongfeng Liu; Guanlin peng

2015-01-01T23:59:59.000Z

336

The effect of density and lint percentage on the resistance of cottonseed to air flow  

E-Print Network [OSTI]

to air flov (air fl. ow dovnvard). . 28 LIST VF TABLKS Table Page I. Values of C and n for the Equation, V ~ CP II. Data for Acid Delinted Seed Density 31. 85 pounds per cubic foot 37 III. Data for Nachine-Delknted Seed Density 26. 6 pounds per.... As these graphs were plotted on logarithmic paper, the relation between air flow rate and pressure drop may be expressed by equations of the form, V w CP ? where "V" is velocity of air flow in feet per minute (sometimes expressed es cubic feet per minute per...

Brashears, Alan Dale

2012-06-07T23:59:59.000Z

337

Simulation of air and mist drilling for geothermal wells  

SciTech Connect (OSTI)

An air drilling model has been developed that accounts for cuttings and mist. Comparison of the model results with previous work shows this model to be more conservative. The equations developed are simple enough to be used in hand calculations, but the full capability of the model is more easily obtained with a computer program. Studies with the model show that volume requirements and standpipe pressures are significantly different for mist drilling compared with air drilling. An improved method for calculating downhole temperatures, pressures, fluid densities, and velocities during air drilling has been developed. Improvements on previous methods include the following. A fully transient thermal analysis of the wellbore and formation is used to determine the flowing temperatures. The effects of flow acceleration are included explicitly in the calculation. The slip velocity between the gas and the cuttings is determined by the use of a separate momentum equation for the cuttings. The possibility of critical flow in the wellbore is tested and appropriate changes in the volume flow rate and standpipe pressure are made automatically. The standpipe and flowing pressures are predicted. The analysis is conservative. The effect of the cuttings on the wellbore flow will tend to overpredict the required volume flow rates. In this paper, the basic equations of fluid flow for a gas with cuttings and mist are presented along with a numerical method for their solution. Several applications of this calculational method are given, showing the effect of flow rate and standpipe pressure in typical air and mist drilling situations.

Mitchell, R.F.

1983-11-01T23:59:59.000Z

338

Effective Rate Period  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Fiscal Year 2014 Fiscal Year 2014 Effective Rate Period As of Beginning of the FY 10/01/2013 - 09/30/2014 Mid-Year Changes (if applicable) 10/01/2013 - 09/30/2014 Power Rates Annual Revenue Requirement Rate Schedule Power Revenue Requirement $73,441,557 CV-F13 Base Resource Revenue Requirement $69,585,875 First Preference Revenue Requirement $3,855,682

339

Integrated Technology Air Cleaners (ITAC): Design and Evaluation  

E-Print Network [OSTI]

of particle air filtration technologies." Indoor Air 12(4):2011a). New air cleaning technologies for reduced commercialnumber 2 Integrated technology air cleaner High efficiency

Fisk, William J.

2014-01-01T23:59:59.000Z

340

Are Ventilation Filters Degrading Indoor Air Quality in California Classrooms?  

E-Print Network [OSTI]

air conditioning  IAQ: Indoor air quality  LBNL: Lawrence Degrading Indoor Air Quality in California Classrooms? HDEGRADING INDOOR AIR QUALITY IN CALIFORNIA CLASSROOMS?

Fisk, Michael G. Apte and William J.

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

LCC Guidance Rates  

Broader source: Energy.gov [DOE]

Notepad text file provides the LCC guidance rates in a numbered format for the various regions throughout the U.S.

342

Draft Tiered Rate Methodology  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

year's weather and other specific factors are removed from the loads of irrigated agriculture. ( ) "Irrigation Rate Mitigation" means the form of a discount by BPA to...

343

Heart Rate Artifact Suppression.  

E-Print Network [OSTI]

??Motion artifact strongly corrupts heart rate measurements in current pulse oximetry systems. In many, almost any motion will greatly diminish the system’s ability to extract… (more)

Dickson, Christopher

2012-01-01T23:59:59.000Z

344

Residential Solar Valuation Rates  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Residential Solar Valuation Rates Karl R. Rbago Rbago Energy LLC 1 The Ideal Residential Solar Tariff Fair to the utility and non-solar customers Fair compensation to...

345

Rapidly Equilibrating Micrometer Film Sampler for Priority Pollutants in Air  

Science Journals Connector (OSTI)

The results were used to calculate the average mass transfer coefficient (50.5 m/day) and generate contour maps that provide guidance in choosing an appropriate EVA sampler for a particular study based on film thickness, deployment time, and the log KOA of the anlayte. ... diffusion and was independent of wind velocity. ... The effect of outside wind speed on PUF disk sampling rates was evaluated by exposing polyurethane foam (PUF) disks to a PCB-contaminated air stream in a wind tunnel over air velocities 0-1.75 m/s. ...

Susan Genualdi; Tom Harner

2012-06-17T23:59:59.000Z

346

Re-Commissioning of a VAV Air-Distribution System  

E-Print Network [OSTI]

P_setpoint=cte Supply circuit Fresh air circuit Extraction Group Atrium Bs1 south 3100 m?/h Return circuit BLOC B BLOC C VAV box 250 to 450 Pa 32 m fire cut-off valve silencer V& : air flow rate - m?/h Mechanized register regulation valve grille PAF Legend Figure 2... box manufacturer, this minimum pressure is around 250 Pa. The calculation, which is presented by Figure 4, shows that, with such a value, the pressure is acceptable in all rooms connected to this AHU. The same calculation shows that the connection...

Andre, P.; Silva, C. A.; Fonseca, N.; Hannay, J.; Lebrun, J.; Lacote, P.

2004-01-01T23:59:59.000Z

347

Radionuclide Air Emissions Report for 2012  

E-Print Network [OSTI]

Air Emissions Annual Reports for DOE Sites,” memo tooffices providing guidance for report preparation (March 22,470E-2012 Radionuclide Air Emission Report for Prepared by

Wahl, Linnea

2014-01-01T23:59:59.000Z

348

Covered Product Category: Room Air Conditioners | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Specifications website. Buying Energy-Efficient Room Air Conditioners When buying room air conditioners directly from commercial sources, choose models that are ENERGY...

349

Aire Valley Environmental | Open Energy Information  

Open Energy Info (EERE)

search Name: Aire Valley Environmental Place: United Kingdom Product: Leeds-based waste-to-energy project developer. References: Aire Valley Environmental1 This article...

350

Air Quality Modeling's Brave New World  

Science Journals Connector (OSTI)

Air Quality Modeling's Brave New World ... A new generation of software systems is set to tackle regional and multipollutant air quality issues. ...

Elaine L. Appleton

2011-06-07T23:59:59.000Z

351

Colorado Air Pollution Control Division - Construction Permits...  

Open Energy Info (EERE)

Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Colorado Air Pollution Control Division - Construction Permits Forms and Air Pollutant Emission...

352

Energy performance of underfloor air distribution systems  

E-Print Network [OSTI]

loss of control of the supply air temperature from the loss of control of the  supply air temperature from the 

Bauman, Fred; Webster, Tom; Linden, Paul; Buhl, Fred

2007-01-01T23:59:59.000Z

353

EML Surface Air Sampling Program, 1990--1993 data  

SciTech Connect (OSTI)

Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory`s Surface Air Sampling Program (SASP) during 1990--1993, with the exception of April 1993, indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the sampling and analytical techniques that were used to collect and measure them. The occasional detection of {sup 137}Cs in some air filter samples may have resulted from resuspension of previously deposited debris. Following the April 6, 1993 accident and release of radionuclides into the atmosphere at a reprocessing plant in the Tomsk-7 military nuclear complex located 16 km north of the Siberian city of Tomsk, Russia, weekly air filter samples from Barrow, Alaska; Thule, Greenland and Moosonee, Canada were selected for special analyses. The naturally occurring radioisotopes that the authors measure, {sup 7}Be and {sup 210}Pb, continue to be detected in most air filter samples. Variations in the annual mean concentrations of {sup 7}Be at many of the sites appear to result primarily from changes in the atmospheric production rate of this cosmogenic radionuclide. Short-term variations in the concentrations of {sup 7}Be and {sup 210}Pb continued to be observed at many sites at which weekly air filter samples were analyzed. The monthly gross gamma-ray activity and the monthly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb measured at sampling sites in SASP during 1990--1993 are presented. The weekly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb for samples collected during 1990--1993 are given for 17 sites.

Larsen, R.J.; Sanderson, C.G.; Kada, J.

1995-11-01T23:59:59.000Z

354

Mountain Air | Open Energy Information  

Open Energy Info (EERE)

Air Air Jump to: navigation, search Name Mountain Air Facility Mountain Air Sector Wind energy Facility Type Commercial Scale Wind Facility Status In Service Owner Terna Energy Developer Terna Energy Energy Purchaser Idaho Power Location Hammett ID Coordinates 42.98719519°, -115.3985024° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.98719519,"lon":-115.3985024,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

355

Missouri Air Conservation Law (Missouri)  

Broader source: Energy.gov [DOE]

This law's purpose is to maintain the purity of the air resources of the state to protect the health, general welfare and physical property of the people, maximum employment and the full industrial...

356

Kansas Air Quality Regulations (Kansas)  

Broader source: Energy.gov [DOE]

All new air contaminant emission sources or alterations to emission sources that are required to be reported shall be in compliance with all applicable emission control regulations at the time that...

357

Natural Air-Conditioning Systems  

Science Journals Connector (OSTI)

Recent research in summer air conditioning utilizing natural sources of coolness* are discussed. These systems are classified according to the sources of coolness, the modes of heat transfer and airflow, and t...

Mehdi N. Bahadori

1986-01-01T23:59:59.000Z

358

ARM - Lesson Plans: Air Pressure  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

activity to work. It is important that students work carefully and slowly. A break in the seal between the cup and card allows air into the cup, causing the water to fall. Note: If...

360

Gas temperature profiles at different flow rates and heating rates suffice to estimate kinetic parameters for fluidised bed combustion  

SciTech Connect (OSTI)

Experimental work on estimation kinetic parameters for combustion was conducted in a bench-scale fluidised bed (FB: 105x200mm). Combustion medium was obtained by using an electrical heater immersed into the bed. The ratio of heating rate (kJ/s) to molar flow rate of air (mol/s) regulated by a rheostat so that the heat of combustion (kJ/mol) can be synthetically obtained by an electrical power supply for relevant O{sub 2}-feedstock concentration (C{sub 0}). O{sub 2}-restriction ratio ({beta}) was defined by the ratio of O{sub 2}-feedstock concentration to O{sub 2}-air concentration (C{sub O{sub 2}-AIR}) at prevailing heating rates. Compressed air at further atmospheric pressure ({approx_equal}102.7kPa) entered the bed that was alumina particles (250{mu}m). Experiments were carried out at different gas flow rates and heating rates. FB was operated with a single charge of (1300g) particles for obtaining the T/T{sub 0} curves, and than C/C{sub 0} curves. The mathematical relationships between temperature (T) and conversion ratio (X) were expressed by combining total energy balance and mass balance in FB. Observed surface reaction rate constants (k{sub S}) was obtained from the combined balances and proposed model was also tested for these kinetic parameters (frequency factor: k{sub 0}, activation energy: E{sub A}, and reaction order: n) obtained from air temperature measurements. It was found that the model curves allow a good description of the experimental data. Thus, reaction rate for combustion was sufficiently expressed. (author)

Suyadal, Y. [Faculty of Engineering, Department of Chemical Engineering, Ankara University, 06100-Tandogan, Ankara (Turkey)

2006-07-15T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

The relationship of metabolic rate to rate of gain in young beef cattle  

E-Print Network [OSTI]

reaches maturity. %1th tl ls ln mind, an attempt has been made to determine whether metabolic rat;e has any relationship to rate of gain ln young beef cattle. REVIEVi OF LITERATVRE It is generally known that the thyroid gland has an impoztant... that of the thyroidoctomized animal decreased to about 1300 calories per square . . . etor pcr day at tho age o'f eight morths, at wi;1ch level it re- mained dto age forty months. The volu. . . e of air inhaled pe. minute is less in t?ie thyroidectomized ar. i. . . al...

Burns, Kenneth Harold

2012-06-07T23:59:59.000Z

362

Numerical simulation of air/H2 combustion processes in a scramjet turbulent flow  

Science Journals Connector (OSTI)

The aim of this work is to develop a numerical approach, based on the Favre's averaged Navier-Stokes equations coupled with a turbulence model and with a complex finite rate Air/Hydrogen combustion kinetic model to simulate the unsteady axisymetric supersonic hydrogen-air mixing processes. The main application is dedicated to the scramjet hypersonic air-breathing propulsion engine. To achieve this goal the Spalart-Allmaras turbulence model (SA) with correction terms to model the compressibility effects and the complete finite rate chemistry model of Jachimowsky involving 13 species and 153 reactions have been implemented in a finite volume code.

Y. Burtschell; S. Seror; J.D. Parisse; D. Zeitoun

2008-01-01T23:59:59.000Z

363

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... ACS MEMBER RATES "Situations Wanted" advertisements will be classified by the chemical held designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2000-02-21T23:59:59.000Z

364

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... ACS MEMBER RATES "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

1997-03-24T23:59:59.000Z

365

Common Air Conditioner Problems | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Common Air Conditioner Problems Common Air Conditioner Problems Common Air Conditioner Problems May 30, 2012 - 6:41pm Addthis A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. What does this mean for me? You can eliminate the most common air conditioner problems before hiring an air conditioning technician. You can do some air conditioner maintenance and repair tasks yourself. One of the most common air conditioning problems is improper operation. If your air conditioner is on, be sure to close your home's windows and outside doors. For room air conditioners, isolate the room or a group of connected rooms as much as possible from the rest of your home.

366

Common Air Conditioner Problems | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Common Air Conditioner Problems Common Air Conditioner Problems Common Air Conditioner Problems May 30, 2012 - 6:41pm Addthis A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. What does this mean for me? You can eliminate the most common air conditioner problems before hiring an air conditioning technician. You can do some air conditioner maintenance and repair tasks yourself. One of the most common air conditioning problems is improper operation. If your air conditioner is on, be sure to close your home's windows and outside doors. For room air conditioners, isolate the room or a group of connected rooms as much as possible from the rest of your home.

367

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy  

Broader source: Energy.gov (indexed) [DOE]

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy Efficiency Standard YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy Efficiency Standard October 11, 2012 - 4:10pm Addthis The U.S. Department of Energy's Office of Enforcement issued a Notice of Noncompliance Determination (Notice) on October 11, 2012, to YMGI Group, LLC (YMGI) regarding through-the-wall split system central air conditioner basic model TTWC-18K-31B. DOE enforcement testing revealed that this model operates at a Seasonal Energy Efficiency Rating (SEER) of 8.3. The current federal standard requires that through-the-wall split system central air conditioners operate at a SEER of 12 or greater. Addthis Related Articles Four Central Air Conditioners Determined Noncompliant With Energy

368

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy Efficiency Standard YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy Efficiency Standard October 11, 2012 - 4:10pm Addthis The U.S. Department of Energy's Office of Enforcement issued a Notice of Noncompliance Determination (Notice) on October 11, 2012, to YMGI Group, LLC (YMGI) regarding through-the-wall split system central air conditioner basic model TTWC-18K-31B. DOE enforcement testing revealed that this model operates at a Seasonal Energy Efficiency Rating (SEER) of 8.3. The current federal standard requires that through-the-wall split system central air conditioners operate at a SEER of 12 or greater. Addthis Related Articles Four Central Air Conditioners Determined Noncompliant With Energy

369

Assessment of Indoor Air Quality Benefits and Energy Costs of Mechanical Ventilation  

SciTech Connect (OSTI)

Intake of chemical air pollutants in residences represents an important and substantial health hazard. Sealing homes to reduce air infiltration can save space conditioning energy, but can also increase indoor pollutant concentrations. Mechanical ventilation ensures a minimum amount of outdoor airflow that helps reduce concentrations of indoor emitted pollutants while requiring some energy for fan(s) and thermal conditioning of the added airflow. This work demonstrates a physics based, data driven modeling framework for comparing the costs and benefits of whole-house mechanical ventilation and applied the framework to new California homes. The results indicate that, on a population basis, the health benefits from reduced exposure to indoor pollutants in New California homes are worth the energy costs of adding mechanical ventilation as specified by ASHRAE Standard 62.2.This study determines the health burden for a subset of pollutants in indoor air and the costs and benefits of ASHRAE's mechanical ventilation standard (62.2) for new California homes. Results indicate that, on a population basis, the health benefits of new home mechanical ventilation justify the energy costs.

Logue, J.M.; Price, P.N.; Sherman, M.H.; Singer, B.C.

2011-07-01T23:59:59.000Z

370

Measuring rates of outdoor airflow into HVAC systems  

SciTech Connect (OSTI)

During the last few years, new technologies have been introduced for measuring the flow rates of outside air into HVAC systems. This document describes one particular technology for measuring these airflows, a system and a related protocol developed to evaluate this and similar measurement technologies under conditions without wind, and the results of our evaluations. We conclude that the measurement technology evaluated can provide a reasonably accurate measurement of OA flow rate over a broad range of flow, without significantly increasing airflow resistance.

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.; Delp, Woody

2002-10-01T23:59:59.000Z

371

Momentum rate probe for use with two-phase flows S. G. Bush,a)  

E-Print Network [OSTI]

of flows including nuclear reactor coolant streams, refrigerants in heating-ventilating air flow rates of these flows span a wide range of values, from those in nuclear power plant cooling systems, through supercritical diesel fuel injection, heating-ventilating and air-conditioning HVAC

Panchagnula, Mahesh

372

Energy audit case studies II—air conditioning (cooling) systems  

Science Journals Connector (OSTI)

This paper discusses a novel methodology for determination of the efficiencies of each segment in a centralized air conditioning (A/C) plant. The methodology is useful analytical tool in energy audit where it can be used for decision support for evolution of energy conservation measures and techno-economic evaluation of the various options. The procedure is applied to three A/C plants of capacity range from 50 to 500 TR. Losses in chilled air ducts and cycling losses in the refrigerant circuit are identified to be the major causes for decrease in the efficiency and capacity under rating of the systems. Effective controls and insulation of air ducts: have been shown to be the most cost effective solutions to improve the energy efficiency of the A/C plants. The generalized experimental data on overall performance of sixteen A/C plants is also provided.

M Siddhartha Bhatt

2000-01-01T23:59:59.000Z

373

2007-2009 Power Rate Adjustments (pbl/rates)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Function Review (PFR) Firstgov FY 2007 2009 Power Rate Adjustments BPA's 2007-2009 Wholesale Power Rate Schedules and General Rate Schedule Provisions (GRSPs) took effect on...

374

Analysis of air pollution and greenhouse gases  

SciTech Connect (OSTI)

The current objective of the project Analysis of Air Pollution and Greenhouse Gases'' is to develop a study of emissions and emission sources that could easily be linked to models of economic activity. Initial studies were conducted to evaluate data currently available linking activity rates and emissions estimates. The emissions inventory developed for the National Acid Precipitation Assessment Program (NAPAP) presents one of the most comprehensive data sets, and was chosen for our initial studies, which are described in this report. Over 99% of the SO{sub 2} emissions, 98% of the NO{sub x} emission and 57% of the VOC emissions from area sources are related to fuel combustion. The majority of emission from these sources are generated by the transportation sector. Activity rates for area sources are not archived with the NAPAP inventory; alternative derivations of these data will be part of the future activities of this project. The availability and completeness of the fuel heat content data in the NAPAP inventory were also studied. Approximately 10% of the SO{sub 2} emissions, 13% of the NO{sub x} emissions and 46% of the VOC emissions are generated by sources with unavailable data for fuel heat content. Initial estimates of pollutant emission rate per unit fuel heat content. Initial estimates of pollutant emission rate per unit fuel heat content were generated. Future studies for this project include the derivation of activity rates for area sources, improved explanations for the default fuel parameters defined in the NAPAP inventory and the development of links to data bases of economic activity.

Benkovitz, C.M.

1992-03-01T23:59:59.000Z

375

Efficiency Ratings for the Daiken AC (Americas), Inc.  

E-Print Network [OSTI]

Efficiency Ratings for the Daiken AC (Americas), Inc. Altherma Air-to-Water Source Heat Pump System Description Model No. Capacity (tons) Space Heating Space Cooling SEER Water Heating Efficiency (E.F.)1 CEC Listing Date Heating Combined Hydronic HSPF E.F. Split Altherma LT ERLQ036

376

Introduction Air Quality and Nitrogen Dioxide  

E-Print Network [OSTI]

- Global update 2005. Primary sources of air pollutants include combustion products from power generationIntroduction Air Quality and Nitrogen Dioxide Air pollution can be defined as "the presence effects to man and/or the environment". (DEFRA) "Clean air is considered to be a basic requirement

377

INDOOR AIR QUALITY QUESTIONNAIRE HUMAN RESOURCES  

E-Print Network [OSTI]

INDOOR AIR QUALITY QUESTIONNAIRE HUMAN RESOURCES FORM Risk and Compliance | One Washington Square THE AIR QUALITY ISSUE AND LOCATION Name: Date: Department: Phone No: Work Location: Suspected Air Quality, humidity, drafts, stagnant air, odors)? Is there a history of flooding or water damage? If so, please list

Eirinaki, Magdalini

378

AIR QUALITY: Control Enters New Phase  

Science Journals Connector (OSTI)

AIR QUALITY: Control Enters New Phase ... Federal enforcement of air pollution is about to enter a new, more technically sophisticated, phase. ... Now air pollution control moves into the criteria and standards period, when numbers eventually will be the basis for enforcement and the country becomes zoned into 32 air quality regions. ...

1968-08-05T23:59:59.000Z

379

Indoor air quality bill opposed by EPA  

Science Journals Connector (OSTI)

Indoor air quality bill opposed by EPA ... Sen. George J. Mitchell (D.-Me.) has introduced a bill to protect the quality of indoor air. ... According to J. Craig Potter, assistant EPA administrator for air and radiation, the "Indoor Air Quality Act of 1987," S. 1629, is a bill whose time has not yet arrived. ...

LOIS EMBER

1987-12-07T23:59:59.000Z

380

Continuous Air Monitor Operating Experience Review  

SciTech Connect (OSTI)

Continuous air monitors (CAMs) are used to sense radioactive particulates in room air of nuclear facilities. CAMs alert personnel of potential inhalation exposures to radionuclides and can also actuate room ventilation isolation for public and environmental protection. This paper presents the results of a CAM operating experience review of the DOE Occurrence Reporting and Processing System (ORPS) database from the past 18 years. Regulations regarding these monitors are briefly reviewed. CAM location selection and operation are briefly discussed. Operating experiences reported by the U.S. Department of Energy and in other literature sources were reviewed to determine the strengths and weaknesses of these monitors. Power losses, human errors, and mechanical issues cause the majority of failures. The average “all modes” failure rate is 2.65E-05/hr. Repair time estimates vary from an average repair time of 9 hours (with spare parts on hand) to 252 hours (without spare parts on hand). These data should support the use of CAMs in any nuclear facility, including the National Ignition Facility and the international ITER experiment.

L. C. Cadwallader; S. A. Bruyere

2008-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

OpenEI - rates  

Open Energy Info (EERE)

U.S. Electric Utility U.S. Electric Utility Companies and Rates: Look-up by Zipcode (Feb 2011) http://en.openei.org/datasets/node/899 This dataset, compiled by NREL and Ventyx, provides average residential, commercial and industrial electricity rates by zip code for both investor owned utilities (IOU) and non-investor owned utilities. Note: the file includes average rates for each utility, but not the detailed rate structure data found in the database available via the zip-code look-up feature on the OpenEI Utilities page (http://en.openei.org/wiki/Gateway:Utilities). The data was released by NREL/Ventyx in February 2011.

382

Water Rate Escalations  

Broader source: Energy.gov [DOE]

Federal agencies need accurate water cost escalation rates to perform life cycle cost analyses for water efficiency projects to meet Executive Order 13514 and Energy Independence and Security Act...

383

Before a Rate Case  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

is made up of two processes. The first part of the IBR is the Integrated Program Review (IPR), which will address proposed program costs prior to their inclusion in a rate case,...

384

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted "advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202. ...

2002-04-15T23:59:59.000Z

385

Tiered Rate Methodology  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rate Period limit. This 23 exception is limited for the duration of this TRM to the first ten requesting utilities that 24 BP-12-A-03 Section 4 Page 46 meet the size threshold and...

386

Stocking Rate Decisions  

E-Print Network [OSTI]

to predict potential forage shortfalls, determine the im- pact of the decision on finances and other ranch re- sources, and make any necessary adjustments before the forage resource is harmed or financial problems occur. Through adequate planning and periodic... rates with limited knowledge of future forage and market conditions. But they can use past records, experience and range surveys to make realistic projections of forage and market conditions (Figure 3). Then, the planned stock- ing rate should...

White, Larry D.; McGinty, Allan

1999-02-15T23:59:59.000Z

387

On Thermonuclear Reaction Rates  

E-Print Network [OSTI]

Nuclear reactions govern major aspects of the chemical evolution od galaxies and stars. Analytic study of the reaction rates and reaction probability integrals is attempted here. Exact expressions for the reaction rates and reaction probability integrals for nuclear reactions in the case of nonresonant, modified nonresonant, screened nonresonant and resonant cases are given. These are expressed in terms of H-functions, G-functions and in computable series forms. Computational aspects are also discussed.

H. J. Haubold; A. M. Mathai

1996-12-02T23:59:59.000Z

388

Tips: Air Ducts | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air Ducts Air Ducts Tips: Air Ducts June 24, 2013 - 7:23pm Addthis Air Ducts: Out of Sight, Out of Mind. The unsealed ducts in your attic and crawlspaces lose air, and uninsulated ducts lose heat -- wasting energy and money. Air Ducts: Out of Sight, Out of Mind. The unsealed ducts in your attic and crawlspaces lose air, and uninsulated ducts lose heat -- wasting energy and money. Your air ducts are one of the most important systems in your home, and if the ducts are poorly sealed or insulated they are likely contributing to higher energy bills. Your home's duct system is a branching network of tubes in the walls, floors, and ceilings; it carries the air from your home's furnace and central air conditioner to each room. Ducts are made of sheet metal, fiberglass, or other materials.

389

Air Breathing Direct Methanol Fuel Cell  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Air Breathing Direct Methanol Fuel Cell Air Breathing Direct Methanol Fuel Cell Air Breathing Direct Methanol Fuel Cell An air breathing direct methanol fuel cell is provided with a membrane electrode assembly, a conductive anode assembly that is permeable to air and directly open to atmospheric air, and a conductive cathode assembly that is permeable to methanol and directly contacting a liquid methanol source. Available for thumbnail of Feynman Center (505) 665-9090 Email Air Breathing Direct Methanol Fuel Cell An air breathing direct methanol fuel cell is provided with a membrane electrode assembly, a conductive anode assembly that is permeable to air and directly open to atmospheric air, and a conductive cathode assembly that is permeable to methanol and directly contacting a liquid methanol

390

Chapter 22: Compressed Air Evaluation Protocol  

SciTech Connect (OSTI)

Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: high-efficiency/variable speed drive (VSD) compressor replacing modulating compressor; compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.

Benton, N.

2014-11-01T23:59:59.000Z

391

Chapter 3 - The Science of Air Pollution  

Science Journals Connector (OSTI)

Abstract Air pollution is defined in various ways, with an introduction to numerous air pollutants in this chapter. The evolution of air pollution science, engineering, and technologies is discussed. The distinction between particulate matter and gaseous air pollutants is made. Particles are described physically, especially with regard to the importance of aerodynamic diameter in terms of human health effects. Stationary and mobile sources of air pollution are discussed, as well as the physical and chemical processes involved in chemical transformation and environmental fate. Air pollution engineering's evolution is considered. The chapter discusses in detail the development of air quality standards and the emergence of laws and regulations to address air pollution. The chapter concludes with a timeline of how air pollution has been perceived over history and how air pollution may change in the future.

Daniel Vallero

2014-01-01T23:59:59.000Z

392

Cat Heart Rate Monitoring  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Cat Heart Rate Monitoring Cat Heart Rate Monitoring Name: Shakti Status: student Grade: 9-12 Location: TX Country: USA Date: Summer 2010 Question: What is the best way to find a cat's heart rate using a stethoscope? Because I have tried to hear their heart beat but their purring is all I can hear. If I shouldn't use a stethoscope, then what should I use? Replies: Hi Shakti! If you want to use a stethoscope, the trick is to get your cat to stop purring. Two good ways that I have found to help stop the purring 1. Cover their nose (generally cats don't like this and will stop purring) or 2. Put on the tap to drip or lightly stream water (also, they generally don't like this and will stop purring). Alternatively, you can get their heart rate from feeling their pulse. A good place to try to feel a pulse is right where the leg attaches to the abdomen - in an area called the inguinal region. Now granted there are some heart conditions that will cause an animals pulse and their heart rates don't match up, and it's hard to feel if you have a fat cat, but it's a good place to try if you are really trying to get a heart rate in a healthy kitty!

393

Lessons learned in modeling Underfloor Air Distribution system  

E-Print Network [OSTI]

Underfloor Air Distribution (UFAD) Design Guide. Atlanta:for design cooling loads in underfloor air distribution (

Lee, Kwang Ho; Schiavon, Stefano; Webster, Tom; Bauman, Fred; Feng, Jingjuan; Hoyt, Tyler

2011-01-01T23:59:59.000Z

394

October 2001 - September 2006 Wholesale Power Rates (rates/previous...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

October 2001 - September 2006 The 2002 Wholesale Power Rate Schedules (base rates) for the FY 2002-2006 rate period were originally established in May 2000 during the WP-02 Rate...

395

Considering Air Density in Wind Power Production  

E-Print Network [OSTI]

In the wind power production calculations the air density is usually considered as constant in time. Using the CIPM-2007 equation for the density of moist air as a function of air temperature, air pressure and relative humidity, we show that it is worth taking the variation of the air density into account, because higher accuracy can be obtained in the calculation of the power production for little effort.

Farkas, Zénó

2011-01-01T23:59:59.000Z

396

Considering Air Density in Wind Power Production  

E-Print Network [OSTI]

In the wind power production calculations the air density is usually considered as constant in time. Using the CIPM-2007 equation for the density of moist air as a function of air temperature, air pressure and relative humidity, we show that it is worth taking the variation of the air density into account, because higher accuracy can be obtained in the calculation of the power production for little effort.

Zénó Farkas

2011-03-11T23:59:59.000Z

397

Analysis of Air Leakage Measurements of US Houses  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Air Leakage Measurements of US Houses Air Leakage Measurements of US Houses Title Analysis of Air Leakage Measurements of US Houses Publication Type Journal Article Year of Publication 2013 Authors Chan, Wanyu R., Jeffrey Joh, and Max H. Sherman Journal Energy and Buildings Start Page 616 Pagination 616-625 Date Published 08/2013 Abstract Building envelope airtightness is important for residential energy use, occupant health and comfort. Weanalyzed the air leakage measurements of 134,000 single-family detached homes in US, using normalizedleakage (NL) as the metric. Weatherization assistance programs (WAPs) and residential energy efficiencyprograms contributed most of the data. We performed regression analyses to examine the relationshipbetween NL and various house characteristics. Explanatory variables that are correlated with NL includeyear built, climate zone, floor area, house height, and whether homes participated in WAPs or if theyare energy efficiency rated homes. Foundation type and whether ducts are located outside or inside theconditioned space are also found to be useful parameters for predicting NL. We developed a regressionmodel that explains approximately 68% of the observed variability across US homes. Of these variablesconsidered, year built and climate zone are the two that have the largest influence on NL. The regressionmodel can be used to predict air leakage values for individual homes, and distributions for groups ofhomes, based on their characteristics. Using RECS 2009 data, the regression model predicts 90% of UShouses have NL between 0.22 and 1.95, with a median of 0.67.

398

High Energy Efficiency Air Conditioning  

SciTech Connect (OSTI)

This project determined the performance of a new high efficiency refrigerant, Ikon B, in a residential air conditioner designed to use R-22. The refrigerant R-22, used in residential and small commercial air conditioners, is being phased out of production in developed countries beginning this year because of concerns regarding its ozone depletion potential. Although a replacement refrigerant, R-410A, is available, it operates at much higher pressure than R-22 and requires new equipment. R-22 air conditioners will continue to be in use for many years to come. Air conditioning is a large part of expensive summer peak power use in many parts of the U.S. Previous testing and computer simulations of Ikon B indicated that it would have 20 - 25% higher coefficient of performance (COP, the amount of cooling obtained per energy used) than R-22 in an air-cooled air conditioner. In this project, a typical new R-22 residential air conditioner was obtained, installed in a large environmental chamber, instrumented, and run both with its original charge of R-22 and then with Ikon B. In the environmental chamber, controlled temperature and humidity could be maintained to obtain repeatable and comparable energy use results. Tests with Ikon B included runs with and without a power controller, and an extended run for several months with subsequent analyses to check compatibility of Ikon B with the air conditioner materials and lubricant. Baseline energy use of the air conditioner with its original R-22 charge was measured at 90 deg F and 100 deg F. After changeover to Ikon B and a larger expansion orifice, energy use was measured at 90 deg F and 100 deg F. Ikon B proved to have about 19% higher COP at 90 deg F and about 26% higher COP at 100 deg F versus R-22. Ikon B had about 20% lower cooling capacity at 90 deg F and about 17% lower cooling capacity at 100 deg F versus R-22 in this system. All results over multiple runs were within 1% relative standard deviation (RSD). All of these values agree well with previous results and computer simulations of Ikon B performance versus R-22. The lower cooling capacity of Ikon B is not a concern unless a particular air conditioner is near its maximum cooling capacity in application. Typically, oversized A/C systems are installed by contractors to cover contingencies. In the extended run with Ikon B, which lasted about 4.5 months at 100 deg F ambient temperature and 68% compressor on time, the air conditioner performed well with no significant loss of energy efficiency. Post-run analysis of the refrigerant, compressor lubricant oil, compressor, compressor outlet tubing, and the filter/dryer showed minor effects but nothing that was considered significant. The project was very successful. All objectives were achieved, and the performance of Ikon B indicates that it can easily be retrofitted into R-22 air conditioners to give 15 - 20% energy savings and a 1 - 3 year payback of retrofit costs depending on location and use. Ikon B has the potential to be a successful commercial product.

Edward McCullough; Patrick Dhooge; Jonathan Nimitz

2003-12-31T23:59:59.000Z

399

U.S. Air Force Fact Sheet Air Force Reserve Officer Training Corps  

E-Print Network [OSTI]

for the Air Force. Personnel and Resources Air Force Reserve Officer Training Corps (ROTC) includes fourU.S. Air Force Fact Sheet Air Force Reserve Officer Training Corps Mission Develop Quality Leaders Reserve Officer Training Corps is the largest and oldest source of commissioned officers for the Air Force

Su, Xiao

400

AIRS Version 6 Release Level 2 Product User Guide AIRS/AMSU/HSB Version 6  

E-Print Network [OSTI]

AIRS Version 6 Release Level 2 Product User Guide Page 1 AIRS/AMSU/HSB Version 6 Level 2 Product Questions to: http://airs.jpl.nasa.gov/AskAirs #12;AIRS Version 6 Release Level 2 Product User Guide Page 2............................................................................................. 7 1.1 EXAMPLE: LEVEL 2 PHYSICAL RETRIEVAL PRODUCT FILE NAMES

Waliser, Duane E.

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

NAQSAT National Air Quality Site Assessment Tool NAQSAT National Air Quality Site Assessment Tool  

E-Print Network [OSTI]

NAQSAT National Air Quality Site Assessment Tool NAQSAT National Air Quality Site Assessment Tool Air Quality Assessment Tool For Livestock Producers & Advisors #12;NAQSAT The National Air Quality Dairymen National Air Quality Site Assessment Tool Benefits for Producers · Voluntarily and securely assess

402

Numerical Analysis of a Cold Air Distribution System  

E-Print Network [OSTI]

Cold air distribution systems may reduce the operating energy consumption of air-conditioned air supply system and improve the outside air volume percentages and indoor air quality. However, indoor temperature patterns and velocity field are easily...

Zhu, L.; Li, R.; Yuan, D.

2006-01-01T23:59:59.000Z

403

An integrated perspective on assessing agricultural air quality  

E-Print Network [OSTI]

An integrated perspective on assessing agricultural air quality Viney P. Aneja* Department. In this paper, we summarise an integrated assessment framework for studying the agricultural air quality issues air quality; air emissions; air pollution; ammonia; animal feeding operations; biogeochemical cycles

Niyogi, Dev

404

A dynamic model for air-based photovoltaic thermal systems working under real operating conditions  

Science Journals Connector (OSTI)

Abstract In this paper a dynamic model suitable for simulating real operating conditions of air-based photovoltaic thermal (PVT) systems is presented. The performance of the model is validated by using the operational data collected from the building integrated photovoltaic (PVT) systems installed in two unique buildings. The modelled air outlet temperature and electrical power match very well with the experimental data. In Solar Decathlon house PVT, the average (RMS) error in air outlet temperatures was 4.2%. The average (RMS) error in electrical power was also 4.2%. In the Sustainable Buildings Research Centre PVT, the average errors (RMS) of PV and air temperatures were 3.8% and 2.2%, respectively. The performance of the PVT system under changing working condition is also analysed in this paper. The analysis includes the effect of ambient air temperature, air inlet temperature, air flow rate and solar irradiation on thermal, electrical, first law and second law efficiencies. Both the thermal and the 1st law efficiencies almost linearly increased with the increase of the ambient temperature. However, the PVT electrical efficiency and the second law efficiency decreased with the increase of the ambient temperature. All efficiencies expect the second law efficiency decreased with increase of the PVT air inlet temperature. The second law efficiency first increased and then reduced. With increasing the air flow rate all the efficiencies increased. The electrical and second law efficiencies become less sensitive when the air flow rate exceeded 300 l/s. Both the thermal and the 1st law efficiencies decreased while the electrical efficiency and the second law efficiency increased with the increase of the solar irradiation. The efficiencies found to be very sensitive for low level of solar irradiations. At about 400 W m?2 irradiation efficiencies became less sensitive.

M. Imroz Sohel; Zhenjun Ma; Paul Cooper; Jamie Adams; Robert Scott

2014-01-01T23:59:59.000Z

405

AIR POLLUTION: Diesel Fuel Culprits  

Science Journals Connector (OSTI)

AIR POLLUTION: Diesel Fuel Culprits ... Low-molecular-weight components aren't necessarily the true culprits of diesel fuel pollution, although they do contribute to it, according to Hertha Skala, assistant director of research, and her coworkers F. G. Padrta and P. C. Samson at Universal Oil Products. ... At the first national symposium on heterogeneous catalysis for control of air pollution, sponsored by Philadelphia's Franklin Institute, Mrs. Skala identified five different classes of oxygenated hydrocarbons found over the full molecular-weight range of diesel fuel components. ...

1968-12-02T23:59:59.000Z

406

Optimising the Fresh Air Economiser  

E-Print Network [OSTI]

Optimising the Fresh Air Economiser Rob Bishop Technical Director Energy Solutions Ltd. Wellington New Zealand ABSTRACT This paper proposes using measurements of CO2 to infer the amount of Outside Air (OA) ventilation delivered to a... and the number of occupants only, but since 2004 has also included a value based on the floor area of the space. In New Zealand, the ventilation code is based on ASHRAE Standard 62:1989 (with local amendments), and has not been updated to include the area...

Biship, R.

2013-01-01T23:59:59.000Z

407

Upper Great Plains Rates information  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rates and Repayment Services Rates and Repayment Services Rates 2010 Firm Power Rate (effective January 1, 2010) Rate Adjustments 2010 Firm Power Rate Adjustment 2009 Firm Power Rate Adjustment IS Rate Adjustments Rate Adjustment Process Rate Orders Signed, December 23, 2009 (16kb pdf) Announcements Firm Electric Service Customer Letter - Preliminary Review of Drought Adder Component, June 27, 2013 (74kb pdf) Customer Letter - Final Notice of Drought Adder Component, October 2, 2013 (68kb pdf) Integrated System (IS) Rates 2014 IS Rates Customer Information Meeting Presentation, October 15, 2013 (611kb pdf) Customer Letter - Notification of 2014 Rates, September 13, 2013 (160kb pdf) 2014 Transmission and Ancillary Services Rate Calculation and 2012 Rate True-up Calculation (4.9mb pdf) 2013 IS Rates

408

Rates of evaporation from swimming pools in active use  

SciTech Connect (OSTI)

The rates of water evaporation from indoor and outdoor swimming pools in active use have been measured and compared with evaporation rates from unoccupied pools and with values calculated by the equation W = (95 + 0.425 v) (pw-pa)Y, where W is evaporation rate, lb/h ft{sup 2}; v is air velocity at water surface, ft/min.; pw is saturation vapor pressure at water temperature, in. Hg; pa is saturation vapor pressure at air dewpoint, in. Hg; and Y is latent heat at pool temperature, Btu/lb. In undisturbed pools, evaporation rates were measured and found to be 74% of the rates obtained by use of the equation. Rates of evaporation from pools in active use increase with the number of swimmers, rising 40--70% above the rates from a quiet water surface. Measurements of evaporation from a pool in use by 15--20 swimmers per 1,000 ft{sup 2} were found to average 26% higher than the rate calculated by the equation.

Smith, C.C.; Loef, G.O.G. [Colorado State Univ., Fort Collins, CO (United States). Solar Energy Applications Lab.; Jones, R.W. [Dept. of Energy, Golden, CO (United States)

1998-10-01T23:59:59.000Z

409

National primary standard for the unit of air kerma, air kerma rate, exposure, exposure rate, and x- and gamma-ray energy flux  

Science Journals Connector (OSTI)

According to the recommendations of the International Commission on Radiation Units and Measurements (ICRU) [2], as well as government decrees of the Russian Federation [3...], at present the basic physical quant...

A. V. Oborin; A. Yu. Villevalde; S. G. Trofimchuk

2012-11-01T23:59:59.000Z

410

BCP Annual Rate Process  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2013 BCP Annual Rate Process 2013 BCP Annual Rate Process Informal Process Rate Activity Schedule (doc) Informal Customer Meeting Thursday March 6, 2013 at 10:30 A.M. Conf Rms 3&4 Informal Customer Meeting Presentation (Pdf) PRS Executive Summary (Mar 07, 2013) (Pdf) FY2014 Final Ten Year Operating Plan PRS Executive Summary (PDF) FORM for Foreign Visits (doc) Formal Process Initial Federal Register Notice (pdf) Public Information Forum March 27,2013 at 10:30 A.M. Conf Rms3&4 Customer Meeting Presentation PIF Presentation (PPT) Presentation Details (pdf) Reclamation Fund Status Report PIF PRS Executive Summary (pdf) PIF Transcripts (PDF) Visitor Center Cost Analysis Questions - Responses Public Comment Forum April 10, 2013 at 10:30 A.M. Conf Rms3&4 PCF Transcripts Customer Letters

411

Multiple System Rate Process  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DSW Multiple System Transmission Rate Process DSW Multiple System Transmission Rate Process Federal Register Notice Withdrawing Rate Proposal (PDF) Formal Process Extension Federal Register Notice (PDF) Customer Savings Under Various MSTR (XLS) Public Information Forum March 29, 2005 Customer Meeting Overview (Power Point) Customer Meeting Overview (PDF) Customer Meeting Transcript (PDF) Public Comment Forum April 6, 2005 Customer Meeting Transcript (PDF) Response Letter 5-17-05 (PDF) Customer Letters Tonopah ID-5/25/05 (PDF) APS-5/26/05 (PDF) SRP-5/27/05 (PDF) RSLynch-6/1/05 (PDF) KRSaline-6/1/05 (PDF) Formal Process Federal Register Notice (Word) Federal Register Notice (PDF) Brochure (Word) Appendices to Brochure: A B C D E1 E2 F1 F2 GH Public Information Forum July 14, 2004 Customer Meeting Overview (Power Point)

412

Air Sealing Your Home | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air Sealing Your Home Air Sealing Your Home Air Sealing Your Home November 26, 2013 - 6:22pm Addthis Save on heating and cooling costs by checking for air leaks in common trouble spots in your home. Save on heating and cooling costs by checking for air leaks in common trouble spots in your home. What does this mean for me? Save money and energy by air sealing your house. Caulking and weatherstripping are simple, effective ways of sealing air leaks in your home. Reducing the amount of air that leaks in and out of your home is a cost-effective way to cut heating and cooling costs, improve durability, increase comfort, and create a healthier indoor environment. Caulking and weatherstripping are two simple and effective air-sealing techniques that offer quick returns on investment, often one year or less. Caulk is

413

Maintaining Your Air Conditioner | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Maintaining Your Air Conditioner Maintaining Your Air Conditioner Maintaining Your Air Conditioner June 18, 2013 - 6:20pm Addthis Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. What does this mean for me? Regular maintenance keeps your air conditioner running as efficiently as possible. Maintaining your air conditioner will save you money by extending the unit's life. An air conditioner's filters, coils, and fins require regular maintenance for the unit to function effectively and efficiently throughout its years of service. Neglecting necessary maintenance ensures a steady decline in air conditioning performance while energy use steadily increases.

414

Maintaining Your Air Conditioner | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Maintaining Your Air Conditioner Maintaining Your Air Conditioner Maintaining Your Air Conditioner June 18, 2013 - 6:20pm Addthis Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. What does this mean for me? Regular maintenance keeps your air conditioner running as efficiently as possible. Maintaining your air conditioner will save you money by extending the unit's life. An air conditioner's filters, coils, and fins require regular maintenance for the unit to function effectively and efficiently throughout its years of service. Neglecting necessary maintenance ensures a steady decline in air conditioning performance while energy use steadily increases.

415

Exergy efficiency of a counterflow air/air heat exchanger with vapour condensation  

Science Journals Connector (OSTI)

The exergy efficiency of a counterflow hot moist air/...?1 for the temperature and humidity ratio of hot moist air respectively are considered. Constant ambient air conditions of 20°C and 0.01 kg·kg?1 were assume...

J. Jilek; J. H. Young

1993-01-01T23:59:59.000Z

416

Review: Clearing the Air: The Health and Economic Damages of Air Pollution in China  

E-Print Network [OSTI]

the assessment of air pollution and its health and economiclargest source of health damages of air pollution in China,to air pollution, and the economic evaluations of health

Lee, Joseph

2009-01-01T23:59:59.000Z

417

Air quality, infant mortality, and the Clean Air Act of 1970  

E-Print Network [OSTI]

We examine the effects of total suspended particulates (TSPs) air pollution on infant health using the air quality improvements induced by the 1970 Clean Air Act Amendments (CAAA). This legislation imposed strict regulations ...

Chay, Kenneth Y.

2003-01-01T23:59:59.000Z

418

Urban Air Quality Management: Detecting and Improving Indoor Ambient Air Quality  

Science Journals Connector (OSTI)

Current air pollution management and air quality control are primarily focused on outdoor and ... which act as public spaces, contaminated indoor air could be public health hazards. In Singapore ... spend a subst...

T. L. Tan; Gissella B. Lebron

2011-01-01T23:59:59.000Z

419

Oil and Gas Air Heaters  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Heating technologies for energy efficiency Vol.III-1-2 Oil and Gas Air Heaters1 Guangxiao Kou Hanqing Wang Jiemin Zhou Doctoral Ph.D Ph.D Candidate Professor Professor Hunan University of Technology Hunan...

Kou, G.; Wang, H.; Zhou, J.

2006-01-01T23:59:59.000Z

420

AN IMPROVED AIR-ENGINE  

Science Journals Connector (OSTI)

...bottom of the reverser heater; a cooler, composed...opposite, and the cold chamber above the...and over again. In operation, the alternate raising...mass of air in the cold chamber above the...surface of the reverser heater, thereby becoming...contrary, withstand bad weather and parasites, and...

1889-08-16T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Air Capture Introduction and Overview  

E-Print Network [OSTI]

first." It is much cheaper to capture CO2 from the flue gas of a coal power plant than from ambient air largely eliminated centralized sources of CO2 emissions, especially at coal and natural gas power plants of a facility that captures CO2 from the flue gas of a coal power plant, keeping all possible assumptions

422

Air pollution control: Indoor hazards  

Science Journals Connector (OSTI)

... the need for further study of the health effects of indoor air pollution, ranging from radon emitted by building materials to the second-hand effects of cigarette smoke, and the ... overlooked in research on the health effects of environmental pollutants. In some cases,such as radon, the report says that there is an "urgent need" to study such health ...

David Dickson

1981-09-10T23:59:59.000Z

423

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2002-03-04T23:59:59.000Z

424

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

1999-10-25T23:59:59.000Z

425

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted"advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2002-12-23T23:59:59.000Z

426

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19067-1612. ...

1997-04-07T23:59:59.000Z

427

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements wilt be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2003-09-15T23:59:59.000Z

428

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted"advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2002-03-25T23:59:59.000Z

429

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

1999-08-16T23:59:59.000Z

430

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2000-06-12T23:59:59.000Z

431

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted"advertisements wilt be classified by the chemical field designated by the members, if not designated, placement will be determined by the first word of the text submitted. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Road, Suite 202, Wayne, PA 19087-1612. ...

2002-05-27T23:59:59.000Z

432

Advertising Rate Information  

Science Journals Connector (OSTI)

Advertising Rate Information ... "Situations Wanted" advertisements will be classified by the chemical field designated by the members. ... State ACS membership status and mail advertisements to: Chemical & Engineering News, Classified Advertising, 676 East Swedesford Koad, Suite 202, Wayne, PA 19087-1612. ...

1998-04-20T23:59:59.000Z

433

AIR FORCE SPECIAL WEAPONS CENTER  

Office of Legacy Management (LM)

HEADQUARTERS aII?y HEADQUARTERS aII?y 9 AIR FORCE SPECIAL WEAPONS CENTER 1 AIR FORCE SYSTEMS COMMAND . - KlRTlAND AIR FORCE BASE, NEW MEXICO - k FINAL REPORT O N AIR FORCE PARTICIPATION PROJECT RULISON .1 O c t o b e r 1969 P r e p a r e d by : CONT INENTAL TEST D I V I S ION DIRECTORATE OF NUCLEAR FIELD OPERATIONS This page intentionally left blank INDEX AIR FORCE PARTICIPATION I N PROJECT RULISON FINAL REPORT PARAGRAPH BASIC REPORT SUBJECT R e f e r e n c e s PAGE 2 G e n e r a l 1 3 P l a n n i n g 3 4 Command a n d C o n t r o l 5 O p e r a t i o n s , G r a n d ' J u n c t i o n M u n i c i p a l A i r p o r t . . ' A i r O p e r a t i o n s C e n t e r , He1 i c o p t e r P a d / ' 7.. - . M a t e r i e l : ' 8 M e d i c a l 1 9 R a d - S a f e C r a s h - R e s c u e S e c u r i t y 2 1 C o m m u n i c a t i o n s ~ d m i n i s t r a t ' i o n Summary ATTACHMENTS ATTACHMENT SUBJECI' 1 F r a g O r d e r 69-1 ( ~ r o j ' e c t RULISON) , AFSWC D

434

Air Pollution Control (Oklahoma) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air Pollution Control (Oklahoma) Air Pollution Control (Oklahoma) Air Pollution Control (Oklahoma) < Back Eligibility Agricultural Fuel Distributor Industrial Investor-Owned Utility Local Government Municipal/Public Utility Rural Electric Cooperative State/Provincial Govt Systems Integrator Tribal Government Utility Savings Category Buying & Making Electricity Program Info State Oklahoma Program Type Environmental Regulations Provider Environmental Quality This chapter enumerates primary and secondary ambient air quality standards and the significant deterioration increments. Significant deterioration refers to an increase in ambient air pollution above a baseline plus a specific increment allowed for one of three classes of areas. It is required for potential sources of air contaminants to register with the

435

Soot formation in aerodynamically strained methane-air and ethylene-air diffusion flames with chloromethane addition  

SciTech Connect (OSTI)

The effects of chloromethane (CH{sub 3}Cl) addition on soot inception in methane-air and ethylene-air counterflow diffusion flames were investigated by varying the concentrations of chloromethane and nitrogen in the fuel stream. Experiments showed a monotonic increase in the critical sooting stretch rate for methane-air flames when methane was replaced by chloromethane, while ethylene and chloromethane flames exhibited a larger sooting tendency than flames under comparable conditions and burning either ethylene or chloromethane alone. For the conditions investigated, the critical sooting stretch rates of methane-chloromethane-nitrogen flames were shown to be primarily a function of the chloromethane loading in the fuel stream. The structure of these flames was modeled using detailed chemistry and transport. Modeling results suggested that the enhancement of soot formation in ethylene-chloromethane flames may be a combined result of increased concentrations of C{sub 2} species and chlorinated C{sub 1} radicals (CH{sub 2}Cl and CHCl). A large rate of the reactions among these species may be the first steps in the molecular growth processes, which leads to the inception of soot particles. (author)

Leylegian, J.C. [ATK GASL NY Operations, 77 Raynor Avenue, Ronkonkoma, NY 11779-6648 (United States)

2008-01-15T23:59:59.000Z

436

E-Print Network 3.0 - air-to-air heat pumps Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

conditions... data on the seasonal performance of air-to-air residential heat pump systems. The purpose of this paper... of operation 10, 197778, the Control House ......

437

BaP Air Quality Modelling Simulation Using CMAQ Air Quality Modelling System  

Science Journals Connector (OSTI)

Air Quality Modelling has become an essential tool to ... in the atmosphere by using last generation of air quality dispersion models with the inclusion of the...

R San José; JL Pérez; M Callen; JM López; A Mastral

2013-01-01T23:59:59.000Z

438

Compressed Air Energy Savings: SAV-AIR Monitor and Control System and the PNW Compressed Air Challenge  

E-Print Network [OSTI]

This paper presents the results from two compressed air programs supported by the Northwest Energy Efficiency Alliance (Alliance) over the last five years. In 1997 the Alliance funded the Northwest regional version of the Compressed Air Challenge...

Anderson, K. J.; Annen, B.; Scott, S.

439

Indoor-outdoor air leakage of apartments and commercial buildings.  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Indoor-outdoor air leakage of apartments and commercial buildings. Indoor-outdoor air leakage of apartments and commercial buildings. Title Indoor-outdoor air leakage of apartments and commercial buildings. Publication Type Report Year of Publication 2006 Authors Price, Phillip N., Arman Shehabi, Wanyu R. Chan, and Ashok J. Gadgil Publisher Lawrence Berkeley National Laboratory Abstract We compiled and analyzed available data concerning indoor-outdoor air leakage rates and building leakiness parameters for commercial buildings and apartments. We analyzed the data, and reviewed the related literature, to determine the current state of knowledge of the statistical distribution of air exchange rates and related parameters for California buildings, and to identify significant gaps in the current knowledge and data. Very few data were found from California buildings, so we compiled data from other states and some other countries. Even when data from other developed countries were included, data were sparse and few conclusive statements were possible. Little systematic variation in building leakage with construction type, building activity type, height, size, or location within the u.s. was observed. Commercial buildings and apartments seem to be about twice as leaky as single-family houses, per unit of building envelope area. Although further work collecting and analyzing leakage data might be useful, we suggest that a more important issue may be the transport of pollutants between units in apartments and mixed-use buildings, an under-studied phenomenon that may expose occupants to high levels of pollutants such as tobacco smoke or dry cleaning fumes.

440

The investigation of exhaust powered, automotive air cycle air conditioning  

E-Print Network [OSTI]

Pressure Ratio Net Power Test Apparatus Available Turbocompressors Turbine and Compressor Wheels Mounted to Shaft Turbocompressor Mounted. to Exhaust Line Total System Test Rig Full Throttle Performance Curves Subscript 'c' Corrected Results 13 13... an automotive air cycle unit which employed a rotary- vaned compressor. The prototype unit developed. cooling over various engine speeds because of the compressor being a positive displacement type which developed fairly high pressures on the order of 40 psia...

Holley, James Andrew

1978-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet)  

SciTech Connect (OSTI)

Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems - a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms - were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

Not Available

2014-02-01T23:59:59.000Z

442

Healthy Zero Energy Buildings (HZEB) Program Interim Report on Cross Sectional Study of Contaminant Levels, Source Strengths, and Ventilation Rates in Retail Stores  

E-Print Network [OSTI]

levels within a commercial retail building. Indoor Air, 18,and Ventilation Rates in Retail Stores  Wanyu R.  Chan, exchange rates of the nine retail stores estimated from the

Chan, Wanyu R.

2014-01-01T23:59:59.000Z

443

Mechanical Air Distribution and Interacting Relationships  

E-Print Network [OSTI]

housing is much tighter today than in 1965 when this article was written. Early last year several counties in central Florida were put on alert for having high concentrations of radon. Infiltration causes radon gas to enter through cracks... in the floor slab and hollow concrete block walls, etc. This has been cited many times by research papers, TV and the local news papers alerting the public of itsf dagger and need for detection and mitigation . Indoor radon concentration is believed...

Tooley, J. J.; Moyer, N. A.

1989-01-01T23:59:59.000Z

444

Rail Coal Transportation Rates  

U.S. Energy Information Administration (EIA) Indexed Site

reports reports Coal Transportation Rates to the Electric Power Sector With Data through 2010 | Release Date: November 16, 2012 | Next Release Date: December 2013 | Correction Previous editions Year: 2011 2004 Go Figure 1. Deliveries from major coal basins to electric power plants by rail, 2010 Background In this latest release of Coal Transportation Rates to the Electric Power Sector, the U.S. Energy Information Administration (EIA) significantly expands upon prior versions of this report with the incorporation of new EIA survey data. Figure 1. Percent of total U.S. rail shipments represented in data figure data Previously, EIA relied solely on data from the U.S. Surface Transportation Board (STB), specifically their confidential Carload Waybill Sample. While valuable, due to the statistical nature of the Waybill data,

445

Plant Tumor Growth Rates  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Plant Tumor Growth Rates Plant Tumor Growth Rates Name: Gina and Maria Location: N/A Country: N/A Date: N/A Question: We are doing a science fair project on if B. Carotene, Green tea, and Grape Seed Extract helps plants against the crown gall disease. We injected sunflowers with agrobacterium tum. one week ago (Sun. Feb. 27, 2000). Our questions is how long will it take for the tumors to grow? We scratched the surface of the stems and injected the agrobacterium in the wound. Also which do you think, in your opinion, will do the best, if any? Our science fair is April 13, do you think we'll have growth before then, atleast enough time to do our conclusion and results? Thank you, any information you forward will be very helpful. Replies: Sunflowers form galls relatively quickly. I usually get them in two weeks at least. Good luck.

446

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Jan. '99 to Feb. '99: -1.7% Feb. '98 to Feb. '99: +19.8% YTD '98 to YTD '99: +15.0% 4,100 4,400 4,700 5,000 5,300 5,600 5,900 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons U.S. Distillate Fuel Sales 2011 2012 2013 Adjusted Growth Rates* Jul '13 to Aug '13: 2.5% Aug '12 to Aug '13: -1.3% YTD '12 to YTD '13: 1.5% 300 400 500 600 700 800 900 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons U.S. Residual Fuel Sales 2011 2012 2013 Adjusted Growth Rates* Jul '13 to Aug '13: -0.8%

447

Detecting Air Leaks | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Detecting Air Leaks Detecting Air Leaks Detecting Air Leaks September 27, 2012 - 6:39pm Addthis For a thorough and accurate measurement of air leakage in your home, hire a qualified technician to conduct an energy assessment, particularly a blower door test. For a thorough and accurate measurement of air leakage in your home, hire a qualified technician to conduct an energy assessment, particularly a blower door test. You may already know where some air leakage occurs in your home, such as an under-the-door draft, but you'll need to find the less obvious gaps to properly air seal your home. For a thorough and accurate measurement of air leakage in your home, hire a qualified technician to conduct an energy assessment, particularly a blower door test. A blower door test, which depressurizes a home, can

448

Improving Regional Air Quality with Wind Power  

Wind Powering America (EERE)

Improving Regional Air Quality with Improving Regional Air Quality with Wind Power National Renewable Energy Laboratory Improving Regional Air Quality with Wind Power National Renewable Energy Laboratory * Clean Air Act (CAA) framework * Air quality challenges * CAA policies as market drivers * Met. Wash. Council of Governments (MWCOG) case study * Environmental Protection Agency (EPA) guidance on State Implementation Plan (SIP) credit for EERE * Model SIP documentation for wind purchases * Related marketing innovations Overview Overview * CAA requires regional air quality plans (SIPs) * "Window of opportunity" - Revised SIPs required by 2006/2007 to meet new 8-hour ozone and PM standards - August 2004 EPA guidance and NREL model SIP documentation for wind purchases Clean Air Act Framework Clean Air Act Framework

449

Air-Conditioning Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air-Conditioning Basics Air-Conditioning Basics Air-Conditioning Basics August 16, 2013 - 1:59pm Addthis Air conditioning is one of the most common ways to cool homes and buildings. How Air Conditioners Work Air conditioners employ the same operating principles and basic components as refrigerators. Refrigerators use energy (usually electricity) to transfer heat from the cool interior of the refrigerator to the relatively warm surroundings; likewise, an air conditioner uses energy to transfer heat from the interior space to the relatively warm outside environment. An air conditioner uses a cold indoor coil called the evaporator. The condenser, a hot outdoor coil, releases the collected heat outside. The evaporator and condenser coils are serpentine tubing surrounded by aluminum fins. This tubing is usually made of copper.

450

Clean Air Act Amendments of 1990  

E-Print Network [OSTI]

Congress is currently debating amendments to the Clean Air Act which would strengthen and enhance the current Clean Air Act. The bill would guarantee a reduction of 10 million tons of sulfur dioxide from 1980 levels; would sharply reduce pollutants...

Hanneschlager, R. E.

451

Environmental History of Air Pollution and Protection  

Science Journals Connector (OSTI)

Concerns about air pollution have a long and complex history. Complaints ... of ancient Athens and Rome. But urban air quality worsened considerably during the Industrial Revolution, ... Despite the tangible natu...

Stephen Mosley

2014-01-01T23:59:59.000Z

452

Ambient Air Quality Criteria (Manitoba, Canada)  

Broader source: Energy.gov [DOE]

The Manitoba Ambient Air Quality Criteria schedule lists maximum time-based pollutant concentration levels for the protection and preservation of ambient air quality within the Province of Manitoba...

453

A New Approach to Industrial Air Conditioning  

E-Print Network [OSTI]

-dryer Systems Division, has marketed industrial drying machinery. These heat reactivated dryers can handle latent loads in industrial air conditioning systems. Through waste heat conservation, air conditioning costs can be reduced 25 to 50%, with applications...

Gravenstreter, T.

1982-01-01T23:59:59.000Z

454

Evolution of US air cargo productivity  

E-Print Network [OSTI]

This thesis provides an overview of the US air cargo industry since airline deregulation in 1978, including a brief overview of the historical evolution of air cargo transport in the US from the early 1900s until the late ...

Donatelli, David J

2012-01-01T23:59:59.000Z

455

Advanced Management of Compressed Air Systems  

Broader source: Energy.gov [DOE]

Find out how a compressed air system works and the benefits of optimal compressed air system performance. This training is designed to help end users as well as industry solution providers learn...

456

EVENT CLOUDS : lighter than air architectural structures  

E-Print Network [OSTI]

EVENT CLOUD is a versatile covering system that allows events to happen independently to weather conditions. It consists of a lighter than air pneumatic structure, filled either with helium or hot air, that covers spaces ...

Peydro Duclos, Ignacio

2014-01-01T23:59:59.000Z

457

Air America: Upholding the Airmen's Bond  

E-Print Network [OSTI]

. Ed Adams, Air America, Conducted rescue operations in Laos and South Vietnam Mr. Marius Burke, Air America, Conducted rescue operations in Laos and South Vietnam Mr. Robert Grealy, CIA, Retired Senior

Kilgard, Michael P.

458

Adverse Health Effects of Air Pollution  

E-Print Network [OSTI]

on clean air: ? 2007: Encouraging energy efficiencies, no more coal plants ? 2009: Retrofitting old coal plants and old diesel engines ? 2011: Disclosure of ?fracking? fluids injected below ground ? Alliance with Texas Business for Clean Air ? Financed...

Haley, R. W.

2011-01-01T23:59:59.000Z

459

Indoor air pollution: a public health perspective  

Science Journals Connector (OSTI)

...control tobacco smoke or gas adsorbers, air filters, and electrostatic tion by-products...ventilation air; formaldehyde sorbant filters Behavioral adjustment: Reduction in human...monitoring equipment, and performance of HVAC systems Table 4. Components of comprehensive...

JD Spengler; K Sexton

1983-07-01T23:59:59.000Z

460

Protective supplied-breathing-air garment  

DOE Patents [OSTI]

A breathing-air garment for isolating a wearer from hostile environments containing toxins or irritants is disclosed. The garment includes a suit and a separate head-protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air-delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air-delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit sealed with an adhesive sealing flap.

Childers, E.L.; von Hortenau, E.F.

1982-05-28T23:59:59.000Z

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Air pollution: Clean up our skies  

Science Journals Connector (OSTI)

... SLCPs cause poor air quality and are responsible for respiratory and cardiovascular diseases. Particulate matter in the atmosphere ... . Particulate matter in the atmosphere is the leading environmental cause of ill health, and air ...

Julia Schmale; Drew Shindell; Erika von Schneidemesser; Ilan Chabay; Mark Lawrence

2014-11-19T23:59:59.000Z

462

Adjusted Growth Rates* Jan.  

U.S. Energy Information Administration (EIA) Indexed Site

Adjusted Adjusted Growth Rates* Jan. '99 to Feb. '99: -1.7% Feb. '98 to Feb. '99: +19.8% YTD '98 to YTD '99: +15.0% U.S. Distillate Fuel Sales 3,000 3,500 4,000 4,500 5,000 5,500 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1998 1999 2000 Adjusted Growth Rates* Dec '99 to Jan '00: -7.4% Jan '99 to Jan '00: -0.1% YTD '99 to YTD '00: -0.1% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1998 1999 2000 Adjusted Growth Rates* Dec '99 to Jan '00: -16.8% Jan '99 to Jan '00: -3.2% YTD '99 to YTD '00: -3.2% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1998 1999 2000 Adjusted Growth Rates* Dec '99 to Jan '00: -9.3% Jan '99 to Jan '00: +3.5% YTD '99 to YTD '00: +3.5% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul

463

Air-shower detection of ultrahigh-energy muons and neutrinos  

Science Journals Connector (OSTI)

We explore the possibility for production of air showers by ultrahigh-energy muons and neutrinos. Such showers must be produced both in the Earth's crust and in the atmosphere. Because of the strong absorption in the Earth the rate of upward-going showers generated by a limiting model of cosmological neutrino flux may be, however, low compared with the background of nearly horizontal muon-generated air showers.

Todor Stanev and H. P. Vankov

1989-09-01T23:59:59.000Z

464

An Evaluation of Steady-State Dehumidification Characteristics of Residential Central Air Conditioners, Final Report  

E-Print Network [OSTI]

of 1973, and the passsage oflegislation requiring development of mandatory minimum efficiency standards for new central air conditioners (and other appliances),manufacturers have been improving the efficiency of central air conditioners dramatically... is for the standard ARI rating conditions (95 F outdoor, 80 F indoor dry bulb, and 67 F indoorwet bulb temperatures). There is not a strong correlation between efficiency (as measured in SEER) and SHR. Both linear and quadraticcorrelations were attempted for the data...

O'Neal, D. L.; Chan, N.; Somasundaram, S.; Katipamula, S.

1987-01-01T23:59:59.000Z

465

Rate Adjustments and Public Involvement  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rate Adjustments and Public Involvement Documents Rate Adjustments and Public Involvement Documents CRSP Transmission 9/16/2013 WAPA-161 FRN, CRSP transmission and ancillary services rates extension Letter announcing two-year extension to CRSP transmission and ancillary services rates Letter announcing revised CRSP transmission rates for FY 2014 Accompanying calculation table for FY 2014 CRSP transmission rate letter Letter announcing revised CRSP transmission rates for FY 2013 Letter announcing revised CRSP transmission rates for FY 2012 Letter announcing revised CRSP transmission rates for FY 2011 Letter announcing revised CRSP transmission rates for FY 2010 SLCA/IP 9/16/2013 WAPA-161 FRN, SLCA/IP firm power rate extension Letter announcing two-year extension to SLCA/IP firm power rate SLCA/IP Tentative Rate Adjustment Schedule

466

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

June '99 to July '99: -5.4% June '99 to July '99: -5.4% July '98 to July '99: +3.3% YTD '98 to YTD '99: +6.3% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* June '99 to July '99: -0.5% July '98 to July '99: -0.4% YTD '98 to YTD '99: +1.1% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* June '99 to July '99: +0.5% July '98 to July '99: +1.0% YTD '98 to YTD '99: -0.3% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* June '99 to July '99: +1.5% July '98 to July '99: +10.2% YTD '98 to YTD '99: +7.2%

467

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Nov '99 to Dec '99: +5.3% Nov '99 to Dec '99: +5.3% Dec '98 to Dec '99: +8.7% YTD '98 to YTD '99: +5.0% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Nov '99 to Dec '99: +6.0% Dec '98 to Dec '99: +4.5% YTD '98 to YTD '99: +1.3% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Nov '99 to Dec '99: +2.4% Dec '98 to Dec '99: +3.0% YTD '98 to YTD '99: +0.9% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Nov '99 to Dec '99: +32.3% Dec '98 to Dec '99: +2.0% YTD '98 to YTD '99: +5.5%

468

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

July '99 to Aug. '99: +4.7% July '99 to Aug. '99: +4.7% Aug. '98 to Aug. '99: +1.3% YTD '98 to YTD '99: +4.7% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* July '99 to Aug. '99: -1.9% Aug. '98 to Aug. '99: -0.4% YTD '98 to YTD '99: +0.9% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* July '99 to Aug. '99: -0.1% Aug. '98 to Aug. '99: -1.4% YTD '98 to YTD '99: -0.7% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* July '99 to Aug. '99: +22.3% Aug. '98 to Aug. '99: +21.1%

469

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Aug '99 to Sep '99: +4.9% Aug '99 to Sep '99: +4.9% Sep '98 to Sep '99: +4.7% YTD '98 to YTD '99: +4.7% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Aug '99 to Sep '99: -2.4% Sep '98 to Sep '99: +0.4% YTD '98 to YTD '99: +1.3% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Aug '99 to Sep '99: -2.1% Sep '98 to Sep '99: +4.6% YTD '98 to YTD '99: 0.0% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Aug '99 to Sep '99: +7.3% Sep '98 to Sep '99: +8.4% YTD '98 to YTD '99: +8.3%

470

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Oct '99 to Nov '99: +0.1% Oct '99 to Nov '99: +0.1% Nov '98 to Nov '99: +5.5% YTD '98 to YTD '99: +4.5% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Oct '99 to Nov '99: -0.7% Nov '98 to Nov '99: +1.7% YTD '98 to YTD '99: +1.1% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Oct '99 to Nov '99: +2.5% Nov '98 to Nov '99: +6.0% YTD '98 to YTD '99: +0.8% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Oct '99 to Nov '99: +9.7% Nov '98 to Nov '99: +2.2% YTD '98 to YTD '99: +6.2%

471

Adjusted Growth Rates*  

U.S. Energy Information Administration (EIA) Indexed Site

Sep '99 to Oct '99: +3.9% Sep '99 to Oct '99: +3.9% Oct '98 to Oct '99: +2.3% YTD '98 to YTD '99: +4.4% U.S. Motor Gasoline Sales 8,000 9,000 10,000 11,000 12,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Sep '99 to Oct '99: -0.2% Oct '98 to Oct '99: -0.9% YTD '98 to YTD '99: +1.0% U.S. Kerosene-Type Jet Fuel Sales 1,500 1,600 1,700 1,800 1,900 2,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Sep '99 to Oct '99: -1.9% Oct '98 to Oct '99: -0.7% YTD '98 to YTD '99: +0.4% U.S. Propane Sales 600 800 1,000 1,200 1,400 1,600 1,800 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Millions of Gallons 1997 1998 1999 Adjusted Growth Rates* Sep '99 to Oct '99: -2.1% Oct '98 to Oct '99: -6.4% YTD '98 to YTD '99: +6.6%

472

Compressed Air Energy Storage for Offshore  

E-Print Network [OSTI]

transmitting peak power levels. A solution to these issues is a novel high-efficiency compressed air energy

Perry Y. Li; Eric Loth; Terrence W. Simon; James D. Van De Ven; Stephen E. Crane

2011-01-01T23:59:59.000Z

473

Preventive Maintenance Strategies for Compressed Air Systems  

Broader source: Energy.gov [DOE]

This tip sheet discusses preventive maintenance strategies for compressed air systems to avoid high equipment repair and replacement costs.

474

Capturing Carbon Dioxide From Air  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Capturing Carbon Dioxide From Air Capturing Carbon Dioxide From Air Klaus S. Lackner (kl2010@columbia.edu; 212-854-0304) Columbia University 500 West 120th Street New York, NY 10027 Patrick Grimes (pgrimes@worldnet.att.net; 908-232-1134) Grimes Associates Scotch Plains, NJ 07076 Hans-J. Ziock (ziock@lanl.gov; 505-667-7265) Los Alamos National Laboratory P.O.Box 1663 Los Alamos, NM 87544 Abstract The goal of carbon sequestration is to take CO 2 that would otherwise accumulate in the atmosphere and put it in safe and permanent storage. Most proposed methods would capture CO 2 from concentrated sources like power plants. Indeed, on-site capture is the most sensible approach for large sources and initially offers the most cost-effective avenue to sequestration. For distributed, mobile sources like cars, on-board capture at affordable cost would not be

475

Clean Air Act, Section 309  

Broader source: Energy.gov (indexed) [DOE]

CLEAN AIR ACT § 309* CLEAN AIR ACT § 309* §7609. Policy review (a) The Administrator shall review and comment in writing on the environmental impact of any matter relating to duties and responsibilities granted pursuant to this chapter or other provisions of the authority of Administrator, contained in any (1) legislation proposed by any Federal department or agency, (2) newly authorized Federal projects for construction and any major Federal agency action (other than a project for construction) to which section 4332(2)(C) of this title applies, and (3) proposed regulations published by any department or agency of the Federal Government. Such written comment shall be made public at the conclusion of any such review. (b) In the event the Administrator determines that any such legislation, action, or regulation

476

NETL: Air Quality III Conference  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Air Quality III Conference - September 12, 2002 Air Quality III Conference - September 12, 2002 Table of Contents Disclaimer Papers and Presentations Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government or any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

477

Airvest's Breath of Fresh Air  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

7 7 The Cutting Edge: Airvest's Breath of Fresh Air Spray booths are a common sight in the industrial sector. Designed to remove pollutants during industrial processes such as spray painting or welding, a booth is a rectangular enclosure open on one side where the worker stands, and equipped on the opposite wall with a fan and filter arrangement to suck away the dirty air. The full-size mannequin in these photographs simulates a worker in a spray booth facing the exhaust filters. In experiments designed by LBL researcher Ashok Gadgil, smoke was released in front of the mannequin to simulate the spraying of paint in the booth. The photo on the left shows the spray booth during standard operation. The smoke-representing a pollutant-is entrained in the eddy that forms in

478

A diffusion approximation approach to stochastic modeling of air conditioning type loads  

E-Print Network [OSTI]

that the air conditioning unit is on and off. In the followino equations, TNIN and TNAX are the lower and upper limit temperatures of the thermostat deadband and To is the outside temperature. Gi 2Gw To Tw Cw Ci $ QeXt To - outside temperature Tw - wall... temperature Ti - inside temperature Gw ? thermal conductance of wall Gi - thermal conductance of air Cw - thermal capacitance of wall Ci ? thermal capacitance of air Qe - rated capacity of cooling unit Xt - zero-one process describing the switching...

Roy, Teresa Henryka

1981-01-01T23:59:59.000Z

479

October 1996 - September 2001 Wholesale Power Rates (rates/previous...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

affecting a specific power purchase. For more specific information see: 1996 Final Wholesale Power and Transmission Rate Schedules: Power Rates (PDF, 84 pages, 188 kb) Ancillary...

480

Making Li-air batteries rechargeable: material challenges. |...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Li-air batteries rechargeable: material challenges. Making Li-air batteries rechargeable: material challenges. Abstract: A Li-air battery could potentially provide three to five...

Note: This page contains sample records for the topic "air infiltration rates" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Health effects of air pollution: some historical notes.  

E-Print Network [OSTI]

that was his first air pollution health effects committeeand direction of air pollution health effects research inof community air pollution, including health ef- fects, has

Whittenberger, J L

1989-01-01T23:59:59.000Z

482

Assessments of biofuel sustainability: air pollution and health impacts  

E-Print Network [OSTI]

Sustainability: Air Pollution and Health Impacts By Chi-and indirect air-pollution and health impacts throughout theparticularly air pollution and health impacts. In this

Tsao, Chi-Chung

2012-01-01T23:59:59.000Z

483

High-Efficiency Window Air Conditioners - Building America Top...  

Broader source: Energy.gov (indexed) [DOE]

Window Air Conditioners - Building America Top Innovation This photo shows a window air conditioning unit in place in a window frame. Window air conditioners are inexpensive,...

484

New indicator approaches for effective urban air quality management  

Science Journals Connector (OSTI)

Measurements of urban air quality at monitoring stations in developed countries have frequently involved the criteria gaseous pollutants, particulates, hazardous air pollutants, perceived air quality and relev...

Peter J. Peterson; W. Peter Williams

1999-12-01T23:59:59.000Z

485

2011: Air Quality Regulations Report | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

: Air Quality Regulations Report 2011: Air Quality Regulations Report 2011 Air Quality Regulations ReportA120911.pdf More Documents & Publications 2011...

486

HVAC Cabinet Air Leakage Test Method - Building America Top Innovation...  

Energy Savers [EERE]

their air sealing practices to reduce the amount of air leaking at ducts and duct boots, testing showed that distribution systems still leaked at air handlers and furnace...

487

Building America Top Innovations 2014 Profile: HVAC Cabinet Air...  

Energy Savers [EERE]

their air sealing practices to reduce the amount of air leaking at ducts and duct boots, testing showed that distribution systems still leaked at air handlers and furnace...

488

A comparison between two underfloor air distribution (UFAD) design tools  

E-Print Network [OSTI]

TWO UNDERFLOOR AIR DISTRIBUTION (UFAD) DESIGN TOOLS Bin CHENunderfloor air distribution (UFAD) design tools (ASHRAE RP-air distribution (UFAD), Cooling load, Design tool, HVAC

Chen, Bin; Schiavon, Stefano; Bauman, Fred S; Chen, Qingyan

2014-01-01T23:59:59.000Z

489

Fact Sheet: Isothermal Compressed Air Energy Storage (October...  

Broader source: Energy.gov (indexed) [DOE]

Isothermal Compressed Air Energy Storage (October 2012) Fact Sheet: Isothermal Compressed Air Energy Storage (October 2012) SustainX will demonstrate an isothermal compressed air...

490

Comparing air quality impacts of hydrogen and gasoline  

E-Print Network [OSTI]

Protection Agency, 2006. Air Quality System (AQS). USpathways on urban air quality. International Journal ofchanges in urban air quality. Only primary pollutants

Sperling, Dan; Wang, Guihua; Ogden, Joan M.

2008-01-01T23:59:59.000Z

491

INDOOR AIR QUALITY MEASUREMENTS IN ENERGY EFFICIENT BUILDINGS  

E-Print Network [OSTI]

of Engineering, Coordinating Committee of Air QualityStandards: Air Quality and Automobile Emission Control, Vol.of ilitrogen Dioxide Air Quality Standards. Paper tlo. 76-

Hollowell, C.D.

2011-01-01T23:59:59.000Z

492

Control of Computer Room Air Conditioning using IT Equipment Sensors  

E-Print Network [OSTI]

control routine to adjust setpoints for supply air temperaturecontrol routine to adjust setpoints for supply air temperaturesupply air temperature is provided. The fan-speed control

Bell, Geoffrey C.

2010-01-01T23:59:59.000Z

493

Hybrid and Advanced Air Cooling | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Hybrid and Advanced Air Cooling Hybrid and Advanced Air Cooling Hybrid and Advanced Air Cooling presentation at the April 2013 peer review meeting held in Denver, Colorado....

494

Making Compressed Air System Decisions  

E-Print Network [OSTI]

. Today, modern, high quality manufacturing facilities require a more scientific approach. Many manufacturing processes require strict controls over compressed air pressure, temperature and purity levels. Competitive pressures also force manufacturers...-lubricated cylinder designs. Reciprocating compressor designs remained the standard for industry until the mid 1970s. During the late 1960s and early 1970s, material and manufacturing advances led to the development of 219 Ingersoll-Rand Co. Davidson, N...

Porri, R. E.

495

Mold: An Indoor Air Pollutant  

E-Print Network [OSTI]

threat. Molds are fungi that produce microscopic cells called spores. Mold spores are present everywhere both outdoors and indoors and spread easily through the air. The most common ?problem? mold in indoor environments is Stachybotrys atra (also called S... is kept dry and clean, and efforts are made to reduce the level of mold spores entering the home. Controlling moisture. To control mold for good, you must solve any moisture problems in your home. Because there are mold spores everywhere, and mold grows...

Harris, Janie

2002-07-08T23:59:59.000Z

496

Physiological responses to air pollutants G. Halbwachs  

E-Print Network [OSTI]

Physiological responses to air pollutants G. Halbwachs Zentrum fur Umwelt- und Naturschutz of fumigation experiments on young plants could be utilized for inter- preting some effects when air pollution of the interaction between air pollution and the forest ecosystem, where not only emission stress is at hand

Boyer, Edmond

497

Air Chemistry and Pollution Spring 2014  

E-Print Network [OSTI]

ATOC 3500 Air Chemistry and Pollution Spring 2014 Meeting: T/Th, 12:30 ­ 1:45 am; Duane G1B25 in the news; for example, the quality of the air we breathe directly affects our health. In addition to mitigate the effects of air pollution. Finally, we examine some recent examples of atmospheric chemical

Toohey, Darin W.

498

Scottish Air Pollution and Health Workshop  

E-Print Network [OSTI]

Scottish Air Pollution and Health Workshop Session 4 Joint Research Policy Needs and Interactions needs and how can we work together effectively on these to reduce the adverse effects of air pollution together effectively on these to reduce the adverse effects of air pollution in Scotland. Modelling

499

Strategy Guideline: Compact Air Distribution Systems  

SciTech Connect (OSTI)

This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

Burdick, A.

2013-06-01T23:59:59.000Z

500

NOAA Air Resources Laboratory Quarterly Activity Report  

E-Print Network [OSTI]

and Hawaii Meteorological Grids for NCEP Atmospheric Turbulence and Diffusion Division 18. Climate 19. Air for Europe convention on Long-Range Transport of Air Pollution. o.russell.bullock@noaa.gov 3. CarbonNOAA Air Resources Laboratory Quarterly Activity Report (January ­ March 2008) Contents Highlights