National Library of Energy BETA

Sample records for air handling units

  1. Laboratory Air Handling Unit System 

    E-Print Network [OSTI]

    Cui, Y.; Liu, M.

    2001-01-01

    balance and moisture balance are given below for the entire building. iQ G26 + hQ G26 + hgQ G26 = rQ G26 + CQ G26 + eQ G26 + ehQ G26 + envQ G26 (1) Where Ge5 = = 2 1 , j jQQ G26 Ge5 = = 2 1 , j jQQ G26 Ge5 = = 2 1 , j jQQ G26 Ge5 = = 2 1 , j... jQQ G26 Ge5 = = 2 1 , j jQQ G26 Figure 1. Schematic diagram of air handling unit system for base system ehMMMM G26G26G26G26 ++= (2) Where Ge5 = = 2 1 , j jMM G26 Ge5 = = 2 1 , j jMM G26 ehWWWWWW G26G26G26G26...

  2. Supply Fan Control for Constant Air Volume Air Handling Units 

    E-Print Network [OSTI]

    Cho, Y.; Wang, G.; Liu, M.

    2007-01-01

    Since terminal boxes do not have a modulation damper in constant volume (CV) air handling unit (AHU) systems, zone reheat coils have to be modulated to maintain the space temperature with constant supply airflow. This conventional control sequence...

  3. An Integrated Air Handling Unit System for Large Commercial Buildings 

    E-Print Network [OSTI]

    Song, L.; Liu, M.

    2001-01-01

    This paper presents an integrated air handling unit system (OAHU) for large commercial buildings. The system introduces outside air into the interior section and circulates the return air to the exterior section. Detailed analytical models...

  4. Model-Based Diagnostics for Air-Handling Units Salsbury and Diamond 1 ModelModel--Based Diagnostics for Air Handling UnitsBased Diagnostics for Air Handling Units

    E-Print Network [OSTI]

    -Based Diagnostics for Air-Handling Units ­ Salsbury and Diamond 1 ModelModel--Based Diagnostics for Air Handling UnitsBased Diagnostics for Air Handling Units Tim Salsbury and Rick Diamond Lawrence Berkeley National Laboratory Berkeley, CA 94720 Introduction In most large air-conditioned buildings, air-handling units

  5. Economizer Applications in Dual-Duct Air-Handling Units 

    E-Print Network [OSTI]

    Joo, I.; Liu, M.

    2002-01-01

    for dual-fan, dual-duct air-handling units. The economizer has significant heating energy penalties for single-fan, dual-duct air-handling units. The penalties are higher than the cooling energy savings when the cold airflow is less than the hot airflow...

  6. Optimal Outside Air Control for Air Handling Units with Humidity Control 

    E-Print Network [OSTI]

    Wang, G.; Liu, M.

    2006-01-01

    Most air handling units (AHUs) in commercial buildings have the (air) economizer cycle to use outside air for free cooling under certain outside air conditions. Ideally the economizer cycle is enabled if outside air enthalpy is less than return air...

  7. The Office Air Handling Unit versus the Two Dedicated Air Handling Unit System 

    E-Print Network [OSTI]

    Song, L.; Liu, M.

    2002-01-01

    operation and control schedules. OAHU system Figure 1 shows the schematic of the OAHU system. The constant interior zone load is assumed. If the interior zone airflow ( ) is higher than the total outside air demand for the entire building... ( ), the OAHU system supplies minimum outside airflow to the building. Otherwise, the OAHU system supplies more outside air to decrease the mechanical cooling. Equation (2) and (3) present the optimal interior zone and exterior zone outside air intake...

  8. Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles 

    E-Print Network [OSTI]

    Xu, K.; Liu, M.; Wang, G.; Wang, Z.

    2007-01-01

    energy for fan, cooling and heating energy. In this paper a simple energy consumption model is established for AHU systems during the economizer and then a optimal supply air temperature control is developed to minimize the total cost of the mechanical...

  9. Automated Proactive Techniques for Commissioning Air-Handling Units

    SciTech Connect (OSTI)

    Katipamula, Srinivas ); Brambley, Michael R. ); Luskay, Larry

    2003-08-30

    Many buildings today use sophisticated building automation systems (BASs) to manage a wide and varied range of building systems. Although the capabilities of the BASs seem to have increased over time, many buildings still are not properly commissioned, operated or maintained. Lack of or improper commissioning, the inability of the building operators to grasp the complex controls, and lack of proper maintenance leads to inefficient operations and reduced lifetimes of the equipment. If regularly scheduled manual maintenance or re-commissioning practices are adopted, they can be expensive and time consuming. Automated proactive commissioning and diagnostic technologies address two of the main barriers to commissioning: cost and schedules. Automated proactive continuous commissioning tools can reduce both the cost and time associated with commissioning, as well as enhance the persistence of commissioning fixes. In the long run, automation even offers the potential for automatically correcting problems by reconfiguring controls or changing control algorithms dynamically. This paper will discuss procedures and processes that can be used to automate and continuously commission the economizer operation and outdoor-air ventilation systems of an air-handling unit.

  10. Using Product Specific Simulation Models in a Tool for Manual Commissioning of Air Handling Units 

    E-Print Network [OSTI]

    Eriksson, J.

    2003-01-01

    . Cetetherm IQHeat. Cetetherm. Ronneby. Sweden. 3. Portland Energy Conservation Inc. Methods for automated and continuous commissioning of build- ings. Air-Conditioning and refrigeraration technol- ogy institute, Arlington, Virginia. 4. T. Haasl, D... SPECIFIC SIMULATION MODELS IN A TOOL FOR MANUAL COMMISSIONING OF AIR HANDLING UNITS JÖRGEN ERIKSSON ĹF-INSTALLATION AB GOTHENBURG, SWEDEN ABSTRACT This short paper describes an outline of a tool for manual commissioning of air handling units...

  11. Performance Analysis of Dual-Fan, Dual-Duct Constant Volume Air-Handling Units 

    E-Print Network [OSTI]

    Joo, I. S.; Liu, M.

    2001-01-01

    Dual-fan, dual-duct air-handling units introduce outside air directly into the cooling duct and use two variable speed devices to independently maintain the static pressure of the hot and the cold air ducts. Analytical models have been developed...

  12. Optimal Airflow Control for Laboratory Air Handling Unit (LAHU) Systems 

    E-Print Network [OSTI]

    Cui, Y.; Liu, M.; Conger, K.

    2002-01-01

    the indoor air quality, This paper presents modeling, optimization procedures and optimal airflow control sequences....

  13. Feasibility Study of Developing a Virtual Chilled Water Flow Meter at Air Handling Unit Level 

    E-Print Network [OSTI]

    Song, L.; Swamy, A.; Shim, G.

    2011-01-01

    In this paper, a virtual Air handling unit (AHU) level water flow meter is explored by using a control valve as a measurement device. The flow through the valve is indirectly calculated using differential pressure over both the valve and its...

  14. From Modelica Models to Fault Diagnosis in Air Handling Units Raymond Sterling1

    E-Print Network [OSTI]

    Cengarle, MarĂ­a Victoria

    From Modelica Models to Fault Diagnosis in Air Handling Units Raymond Sterling1 , Peter Struss2 Engineering, Ryan Institute, NUI Galway, Ireland 2 Computer Science Department, Technische Universität München raymond.sterling@nuigalway.ie, struss@in.tum.de Abstract This paper presents a methodology for model

  15. Analysis of the Energy-Saving Potential of a Three-Rotary Wheel Fresh Air-Handling Unit 

    E-Print Network [OSTI]

    Hao, X.; Zhang, G.; Zou, S.; Liu, H.

    2006-01-01

    To evaluate the energy-saving potential of a proposed three-rotary wheel fresh air-handling unit (TRWFAHU), it is numerically simulated with weather data of Changsha by using a mathematical model. Compared with a conventional fresh air-handling unit...

  16. Optimal Control in Three-deck Multi-Zone Air-Handling Units: A Case-Study 

    E-Print Network [OSTI]

    Joo, I. S.; Song, L.; Liu, M.; Douglas, B.

    2008-01-01

    A multi-zone air-handling unit was popular several decades ago due to the convenience of small sized modular units, which were inexpensive to install and easily maintained in a mechanical room. The cost and convenience proved to be of little benefit...

  17. Uncertainty Analysis for a Virtual Flow Meter Using an Air-Handling Unit Chilled Water Valve

    SciTech Connect (OSTI)

    Song, Li; Wang, Gang; Brambley, Michael R.

    2013-04-28

    A virtual water flow meter is developed that uses the chilled water control valve on an air-handling unit as a measurement device. The flow rate of water through the valve is calculated using the differential pressure across the valve and its associated coil, the valve command, and an empirically determined valve characteristic curve. Thus, the probability of error in the measurements is significantly greater than for conventionally manufactured flow meters. In this paper, mathematical models are developed and used to conduct uncertainty analysis for the virtual flow meter, and the results from the virtual meter are compared to measurements made with an ultrasonic flow meter. Theoretical uncertainty analysis shows that the total uncertainty in flow rates from the virtual flow meter is 1.46% with 95% confidence; comparison of virtual flow meter results with measurements from an ultrasonic flow meter yielded anuncertainty of 1.46% with 99% confidence. The comparable results from the theoretical uncertainty analysis and empirical comparison with the ultrasonic flow meter corroborate each other, and tend to validate the approach to computationally estimating uncertainty for virtual sensors introduced in this study.

  18. Optimization Control Strategy for an Air Handling Unit with Dedicated Rotary Desiccant Dehumidification Wheel in Hot and Humid Climate 

    E-Print Network [OSTI]

    Watt, J.

    2013-01-01

    STRATEGY FOR AN AIR HANDLING UNIT WITH DEDICATED ROTARY DESICCANT DEHUMIDIFICATION WHEEL IN HOT & HUMID CLIMATE Jim Watt Montr?al, Qu?bec October 8, 2013 Outline ? Background ? Introduction?of?desiccant?dehumidification? process ? Mathematical...?Sorption?Process Model?calibration HCU1 HCU2 DB(?F) WB(?F) DB(?F) WB(?F) Inlet 52 52 50 50 Design?outlet 70 54.9 69 53.2 Model?outlet 70.7 55.1 69.7 53.5 Error 0.94% 0.42% 1.03% 0.47% DESCRIPTION?OF?DEDICATED?HUMIDITY? CONTROL?UNITS?(HCU) Run#?1?DESIGN R A W B C...

  19. Optimal Terminal Box Control for Single Duct Air-Handling Units 

    E-Print Network [OSTI]

    Cho, Y.; Vondal, J.; Wang, G.; Liu, M.

    2006-01-01

    Terminal boxes maintain room temperature by modulating supply air temperature and airflow in building HVAC systems. Terminal boxes with conventional control sequences often supply inadequate airflow to a conditioned space, resulting in occupant...

  20. Exploring Maximum Humidity Control and Energy Conservation Opportunities with Single Duct Single Zone Air-Handling Units 

    E-Print Network [OSTI]

    Zhou, J.; Wei, G.; Turner, W. D.; Deng, S.; Claridge, D.

    2006-01-01

    the outside air. However, it also involves major ductwork changes. 2.3 Variable speed control of supply airflow A variable speed drive (VFD) saves fan power by slowing down the fan speed and delivering less supply air to the conditioned space during... by adjusting the supply fan speed. However, if the space cooling load drops below the point where the supply airflow reaches the minimum flow required for proper ventilation, the supply air temperature has to be raised to keep the space temperature from...

  1. Development of an Online Expert Rule Based Automated fault Detection and Diagnostic (AFDD) Tool for Air Handling Units: Beta Test Results 

    E-Print Network [OSTI]

    Bruton, K.; Coakley, D.; O'Donovan, P.; Keane, M.; O'Sullivan, D.

    2013-01-01

    Units (AHU) in HVAC systems to rectify faulty operation. Studies have also demonstrated that continuous commissioning of building systems for optimum efficiency can yield savings of an average of over 20% of total energy cost. Automated Fault Detection...

  2. An Advanced Economizer Controller for Dual Duct Air Handling Systems - with a Case Application 

    E-Print Network [OSTI]

    Liu, M.; Claridge, D. E.

    1996-01-01

    Heating penalty is expected when economizers are applied to dual-duct air handling systems. The heating penalty can even be higher than the cooling savings when the hot air flow is higher than the cold air flow. To avoid the excessive heating...

  3. Transpired Solar Collector at NREL's Waste Handling Facility Uses Solar Energy to Heat Ventilation Air

    SciTech Connect (OSTI)

    2010-09-08

    The transpired solar collector was installed on NREL's Waste handling Facility (WHF) in 1990 to preheat ventilation air. The electrically heated WHF was an ideal candidate for the this technology - requiring a ventilation rate of 3,000 cubic feet per meter to maintain safe indoor conditions.

  4. Implementation of the Laboratory Air Handling Unit Systems (LAHU) 

    E-Print Network [OSTI]

    Cui, Y.; Liu, M.; Conger, K.

    2003-01-01

    The LAHU system has been designed, installed, and commissioned in a large university research building. This paper provides detailed information about the demonstration project, including the specific LAHU system mechanical design, optimal airflow...

  5. Self-correcting Controls for Air Handling Units

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Utility Resources News & Events Expand News & Events Skip navigation links Smart Grid Demand Response Energy Efficiency Emerging Technologies Current Research Portfolio...

  6. Automatic Continuous Commissioning of Measurement Instruments in Air Handling Units 

    E-Print Network [OSTI]

    Xiao, F.; Wang, S.

    2006-01-01

    -statistic and the Q-contribution plot. The fault isolation ability against typical component faults is improved using knowledge-based analysis. A novel condition-based adaptive scheme is developed to update the PCA models with the operation conditions for continuous...

  7. Self-correcting Controls for Air Handling Units

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,

  8. Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature? 

    E-Print Network [OSTI]

    Wei, G.; Turner, W. D.; Claridge, D.; Liu, M.

    2002-01-01

    The supply air temperature set point for a singleduct constant air volume air handling unit (AHU) system is often reset based on either return air temperature or outside air temperature in order to reduce simultaneous cooling and heating energy...

  9. UNITED STATES AIR FORCE OUTSIDE THE NATIONAL CAPITAL REGION

    E-Print Network [OSTI]

    program in order to reduce Federal employee's contribution to traffic congestion and air pollutionUNITED STATES AIR FORCE OUTSIDE THE NATIONAL CAPITAL REGION PUBLIC TRANSPORTATION BENEFIT PROGRAM): ____________ City (Residence): __________________________State: _______________ Zip Code: ________________ Air Force

  10. ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES

    SciTech Connect (OSTI)

    Sexton, L.; Hanks, D.; Degange, J.; Brant, H.; Hall, G.; Cable-Dunlap, P.; Anderson, B.

    2011-06-07

    Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear ES when used during unannounced inspections, design information verification, limited frequency unannounced access, and complementary access visits at bulk handling facilities. Analysis of technical features required for tamper indication and resistance will demonstrate the viability of successful application of the system in taking ES within a bulk handling location. Further exploration of putting this technology into practice is planned to include mapping uranium enrichment facilities for the identification of optimal for installation of air monitoring devices.

  11. An advanced economizer controller for dual-duct air-handling systems -- with a case application

    SciTech Connect (OSTI)

    Liu, M.; Claridge, D.E.; Park, B.Y.

    1997-12-31

    A heating penalty is expected when economizers are applied to dual-duct air-handling systems. The heating penalty can be even higher than the cooling savings when the hot airflow is higher than the cold airflow. To avoid the excessive heating penalty, advanced economizers are developed in this paper. The application of the advanced economizer has resulted in savings of $7,000/yr in one 95,000-ft{sup 2} (8,800-m{sup 2}) school building since 1993. The impacts of cold and hot deck settings on the energy consumption are also discussed.

  12. Proposal for the award of a contract for the supply, assembly and commissioning of air-handling installations for nine LEP surface buildings

    E-Print Network [OSTI]

    1986-01-01

    Proposal for the award of a contract for the supply, assembly and commissioning of air-handling installations for nine LEP surface buildings

  13. Transpired Solar Collector at NREL's Waste Handling Facility Uses Solar Energy to Heat Ventilation Air (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2010-09-01

    The transpired solar collector was installed on NREL's Waste handling Facility (WHF) in 1990 to preheat ventilation air. The electrically heated WHF was an ideal candidate for the this technology - requiring a ventilation rate of 3,000 cubic feet per meter to maintain safe indoor conditions.

  14. Domestic violence prevention effectiveness in the United States Air Force 

    E-Print Network [OSTI]

    Hall, Jennifer Michelle

    2005-08-29

    In 2000, the Department of Defense task force estimated roughly 8.8 in every 1,000 military children were victims of some form of maltreatment. In response to the rising incidence of child maltreatment in the military the United Stated Air Force...

  15. Eielson Air Force Base Operable Unit 2 baseline risk assessment

    SciTech Connect (OSTI)

    Lewis, R.E.; Jarvis, T.T.; Jarvis, M.R.; Whelan, G.

    1994-10-01

    Operable Unit 2 at Eielson Air Force Base (AFB) near Fairbanks, is one of several operable units characterized by petroleum, oil, and lubricant contamination, and by the presence of organic products floating at the water table, as a result of Air Force operations since the 1940s. The base is approximately 19,270 acres in size, and comprises the areas for military operations and a residential neighborhood for military dependents. Within Operable Unit 2, there are seven source areas. These source areas were grouped together primarily because of the contaminants released and hence are not necessarily in geographical proximity. Source area ST10 includes a surface water body (Hardfill Lake) next to a fuel spill area. The primary constituents of concern for human health include benzene, toluene, ethylbenzene, and xylenes (BTEX). Monitored data showed these volatile constituents to be present in groundwater wells. The data also showed an elevated level of trace metals in groundwater.

  16. Grain Handling and Transportation Policy in Canada: Implications for the United States

    SciTech Connect (OSTI)

    Nolan, James; Peterson, Steven K

    2015-01-01

    The grain handling and transportation system in Canada (GHTS) is currently going through a major transition, both with respect to handling and transportation. Historically, the system has pitted farmers against the railways with respect to securing individual fair shares of grain revenues. But with the removal of the single desk marketing and logistics function of the Canadian Wheat Board (CWB) in late 2012, a very interesting and potentially game-changing outcome is emerging with respect to the new functionality of the grain companies in the Canadian system. While historical awareness of rail s natural monopoly position in the grain handling system has kept that sector regulated (in several ways) for close to a century, we are now starting to see the effects of a less than competitive Canadian grain handling sector on revenue sharing, along with renewed movement in the industry with respect to buyouts and potential mergers. This overview will highlight some of the changes now occurring and how they are potentially going to interact or evolve as the system moves forward. For example, the on-going regulatory instrument used to regulate grain transportation rates in Canada (called the maximum revenue entitlement (MRE) or revenue cap) is under current debate because of the introduction a few months ago of a modification to an old regulatory instrument known as extended (or reciprocal) interswitching. As opposed to the revenue cap which is a direct intervention on monopoly behavior, extended interswitching is designed to encourage the major Canadian grain carriers to compete with one another and potentially seek out new traffic (Nolan and Skotheim, 2008). But the most intriguing aspect of extended interswitching is how it might allow a major rail carrier from the U.S. to solicit grain traffic in some areas of the Canadian grain transportation system.

  17. Evaluating Ozone Air Pollution Effects on Pines in the Western United States

    E-Print Network [OSTI]

    Evaluating Ozone Air Pollution Effects on Pines in the Western United States United States. Evaluating ozone air pollution effects on pines in the western United States. Gen. Tech. Rep. PSW­GTR­155. Historical and technical background is provided about ozone air pollution effects on ponderosa (Pinus

  18. Reducing Building Energy Costs Using Optimized Operation Strategies for Constant Volume Air Handling Systems 

    E-Print Network [OSTI]

    Liu, M.; Athar, A.; Reddy, A.; Claridge, D. E.; Haberl, J. S.; White, E.

    1994-01-01

    , they involve resetting the cooling deck or heating deck temperature according to the ambient temperature such that maximum energy efficiency can be achieved without compromising indoor air quality and comfort. Extended O&M Measures optimize system..., building energy consumption can be further reduced even after these traditional O&M measures are applied. This involves optimal adjusting of cold deck and hot deck settings according to the ambient temperature and organizing cold deck settings properly...

  19. China's international trade and air pollution in the United States

    E-Print Network [OSTI]

    2014-01-01

    boundary transport of air pollution (31) must confront theTransport of Asian air pollution to North America. Geophys2010) Hemispheric Transport of Air Pollution 2010 Executive

  20. Air pollution and childhood respiratory allergies in the United States

    E-Print Network [OSTI]

    Parker, JD; Akinbami, LJ; Woodruff, TJ

    2008-01-01

    GG. 2006. Ambient air pollution and asthma exacerbations inallergic symptoms and air pollution among a nationwideincreases in indices of air pollution have been found to

  1. Proposal for an Adsorption Solar-Driven Air-Conditioning Unit for Public Offices 

    E-Print Network [OSTI]

    Elsamni, O. A.; Sahmarani, K.J.; Obied, F. K.

    2010-01-01

    A simple prototype air conditioning unit driven entirely by solar energy is proposed aiming at replacing the conventional vapor compression air conditioning systems which are reasonable for the global warming. The proposed ...

  2. 2013 Data Update: Trends and Market Forces Shaping Small Community Air Service in the United States

    E-Print Network [OSTI]

    Wittman, M.D.

    2014-05-20

    This document is an update to MIT Small Community Air Service White Paper No. 1—Trends and Market Forces Shaping Small Community Air Service in the United States1. This report provides updated analysis and data appendices ...

  3. A Probability Extension of PCA to Detect and Diagnose Sensor Faults in Air Handling Units 

    E-Print Network [OSTI]

    Li, Z.

    2011-01-01

    Due to sensor faults, it is a challenge to successfully detect and diagnose component faults in HVAC systems. The Principal Component Analysis (PCA) method has become a popular method to tackle this problem in recent years, but PCA is not capable...

  4. Building Aautomation system embedded air-handling unit performance degradation detector 

    E-Print Network [OSTI]

    Song, L.; Wang, G.

    2014-01-01

    Acknowledgements Dr. Gang Wang University of Miami Dr. Mike Brambley PNNL Funding agencies: 1. PNNL (2011): Summer research. 2. ASHRAE (2011-2013): Developing standard procedures for filling climate data gaps for use in building performance monitoring and analysis...

  5. Impacts of Water Loop Management on Simultaneous Heating and Cooling in Coupled Control Air Handling Units 

    E-Print Network [OSTI]

    Guan, W.; Liu, M.; Wang, J.

    1998-01-01

    The impacts of the water loop management on the heating and cooling energy consumption are investigated by using model simulation. The simulation results show that the total thermal energy consumption can be increased by 24% for a typical AHU in San...

  6. A Specific Multi-channel Photon-Counting Unit for Air-Pollution Measurement

    E-Print Network [OSTI]

    Athens, University of

    A Specific Multi-channel Photon-Counting Unit for Air-Pollution Measurement Papageorgas P.1.g. confocal microscopy), air pollution optical measurements, laser sounding of the atmosphere for the in situ quantitative monitoring of up to five air pollutants simultaneously and one calibration channel

  7. A Novel Procedure to Determine Optimal Air Static Pressure Set-points and Reset Schedules in VAV Air Handling Units 

    E-Print Network [OSTI]

    Zhu, Y.; Liu, M.; Claridge, D. E.; Turner, W. D.; Powell, T.

    1998-01-01

    . The optimal schedules for the system with DDC controller can also have the low and high limits. A DDDFVAV system has two static pressure sensors. The VFD for hot deck and cold deck fans are controlled separately. Figure 1 shows the diagram of the box... schedules SP,, If the EMCS monitored airflow CFM, then SPo, will be: SP,, = SP,, If SP,, SPhi (10") The flow may be laminar flow when the flow rate is too low. So, the low limit SP,, has to be used. The high limit...

  8. Air-Cooled Stack Freeze Tolerance Freeze Failure Modes and Freeze Tolerance Strategies for GenDriveTM Material Handling Application Systems and Stacks Final Scientific Report

    SciTech Connect (OSTI)

    Hancock, David, W.

    2012-02-14

    Air-cooled stack technology offers the potential for a simpler system architecture (versus liquid-cooled) for applications below 4 kilowatts. The combined cooling and cathode air allows for a reduction in part count and hence a lower cost solution. However, efficient heat rejection challenges escalate as power and ambient temperature increase. For applications in ambient temperatures below freezing, the air-cooled approach has additional challenges associated with not overcooling the fuel cell stack. The focus of this project was freeze tolerance while maintaining all other stack and system requirements. Through this project, Plug Power advanced the state of the art in technology for air-cooled PEM fuel cell stacks and related GenDrive material handling application fuel cell systems. This was accomplished through a collaborative work plan to improve freeze tolerance and mitigate freeze-thaw effect failure modes within innovative material handling equipment fuel cell systems designed for use in freezer forklift applications. Freeze tolerance remains an area where additional research and understanding can help fuel cells to become commercially viable. This project evaluated both stack level and system level solutions to improve fuel cell stack freeze tolerance. At this time, the most cost effective solutions are at the system level. The freeze mitigation strategies developed over the course of this project could be used to drive fuel cell commercialization. The fuel cell system studied in this project was Plug Power's commercially available GenDrive platform providing battery replacement for equipment in the material handling industry. The fuel cell stacks were Ballard's commercially available FCvelocity 9SSL (9SSL) liquid-cooled PEM fuel cell stack and FCvelocity 1020ACS (Mk1020) air-cooled PEM fuel cell stack.

  9. Handling Pyrophoric Reagents

    SciTech Connect (OSTI)

    Alnajjar, Mikhail S.; Haynie, Todd O.

    2009-08-14

    Pyrophoric reagents are extremely hazardous. Special handling techniques are required to prevent contact with air and the resulting fire. This document provides several methods for working with pyrophoric reagents outside of an inert atmosphere.

  10. Technology assessment of vertical and horizontal air drilling potential in the United States. Final report

    SciTech Connect (OSTI)

    Carden, R.S.

    1993-08-18

    The objective of the research was to assess the potential for vertical, directional and horizontal air drilling in the United States and to evaluate the current technology used in air drilling. To accomplish the task, the continental United States was divided into drilling regions and provinces. The map in Appendix A shows the divisions. Air drilling data were accumulated for as many provinces as possible. The data were used to define the potential problems associated with air drilling, to determine the limitations of air drilling and to analyze the relative economics of drilling with air versus drilling mud. While gathering the drilling data, operators, drilling contractors, air drilling contractors, and service companies were contacted. Their opinion as to the advantages and limitations of air drilling were discussed. Each was specifically asked if they thought air drilling could be expanded within the continental United States and where that expansion could take place. The well data were collected and placed in a data base. Over 165 records were collected. Once in the data base, the information was analyzed to determine the economics of air drilling and to determine the limiting factors associated with air drilling.

  11. Air Transportation And Socioeconomic Connectivity In The United States Since Deregulation

    E-Print Network [OSTI]

    Tam, Ryan

    In light of ongoing threats to the viability of traditional airline business models and the provision of air service in the United States, this paper studies the fundamental interdependence of the national economy and the ...

  12. Impact of Air Transportation on Regional Economic and Social Connectivity in the United States

    E-Print Network [OSTI]

    Tam, Ryan

    This paper identifies some of the forces that influence the impact of air transportation on regional connectivity and economic productivity in the United States. In light of recent threats to the financial viability of the ...

  13. Development of models for series and parallel fan variable air volume terminal units 

    E-Print Network [OSTI]

    Furr, James C., Jr

    2007-09-17

    Empirical models of airflow output and power consumption were developed for series and parallel fan powered variable air volume terminal units at typical design pressure conditions. A testing procedure and experimental setup were developed to test...

  14. United States Air Force fighter jet maintenance Models : effectiveness of index policies

    E-Print Network [OSTI]

    Kessler, John M. (John Michael)

    2013-01-01

    As some of the most technically complex systems in the world, United States fighter aircraft require a complex logistics system to sustain their reliable operation and ensure that the day-to-day Air Force missions can be ...

  15. General Guidelines for the Disposal of Refrigerators, Freezers, and other Refrigeration Abandon or dispose of refrigerators, freezers, or window air conditioning units in

    E-Print Network [OSTI]

    Cina, Jeff

    not Abandon or dispose of refrigerators, freezers, or window air conditioning units in dumpsters or in common working and nonworking household refrigeration units (refrigerators, freezers, window air conditioning

  16. Room Temperature Control During Season Switchover with Single Duct Variable Air Volume System Without Reheat 

    E-Print Network [OSTI]

    Liu, C.; Deng, S.; Claridge, D. E.; Turner, W. D.; Bruner, H.

    2003-01-01

    The Langford “A” building houses the College of Architecture on TAMU campus. There are ten singleduct variable air volume (VAV) air-handling units (AHUs) without reheat serving the building. The local pneumatic thermostats modulate the dampers...

  17. NOISE CONTROL METHODS FOR A RECIPROCATING AIR COMPRESSOR USED IN FUEL CELL AUXILIARY POWER UNIT (APU)

    E-Print Network [OSTI]

    Carver, Jeffrey C.

    NOISE CONTROL METHODS FOR A RECIPROCATING AIR COMPRESSOR USED IN FUEL CELL AUXILIARY POWER UNIT What is Fuel Cell APU? Why use APU? To reduce overall noise levels in a fuel cell auxiliary power unit (APU) Main Components Foundation Power source Microphones Spectrum analyzer Stack of fuel cells

  18. Air pollution modelling using a graphics processing unit with CUDA

    E-Print Network [OSTI]

    Molnar, Ferenc; Meszaros, Robert; Lagzi, Istvan; 10.1016/j.cpc.2009.09.008

    2010-01-01

    The Graphics Processing Unit (GPU) is a powerful tool for parallel computing. In the past years the performance and capabilities of GPUs have increased, and the Compute Unified Device Architecture (CUDA) - a parallel computing architecture - has been developed by NVIDIA to utilize this performance in general purpose computations. Here we show for the first time a possible application of GPU for environmental studies serving as a basement for decision making strategies. A stochastic Lagrangian particle model has been developed on CUDA to estimate the transport and the transformation of the radionuclides from a single point source during an accidental release. Our results show that parallel implementation achieves typical acceleration values in the order of 80-120 times compared to CPU using a single-threaded implementation on a 2.33 GHz desktop computer. Only very small differences have been found between the results obtained from GPU and CPU simulations, which are comparable with the effect of stochastic tran...

  19. Air Quality Impacts of Distributed Energy Resources Implemented in the Northeastern United States

    E-Print Network [OSTI]

    Dabdub, Donald

    fine particulate matter (PM2.5) concentrations reach 3 g/m3 and are located off the coast of New JerseyAir Quality Impacts of Distributed Energy Resources Implemented in the Northeastern United States and Energy Program, National Fuel Cell Research Center, The Henry Samueli School of Engineering, University

  20. Sensitivity of air quality to potential future climate change and emissions in the United1 States and major cities2

    E-Print Network [OSTI]

    Nenes, Athanasios

    1 Sensitivity of air quality to potential future climate change and emissions in the United1 States and future air quality is compared for the years 2006-2010 and17 2048-2052 over the contiguous United States affected by changes in climate, land use and pollutant38 emissions [Weaver et al., 2009]. Predictions

  1. United States Office of Air and Radiation EPA 402-R-96-017 Environmental Protection Office of Solid Waste and

    E-Print Network [OSTI]

    United States Office of Air and Radiation EPA 402-R-96-017 Environmental Protection Office of Solid FOR RADIOACTIVELY CONTAMINATED SITES Prepared for U.S. Environmental Protection Agency Office of Air and Radiation Office of Radiation and Indoor Air Radiation Protection Division Center for Remediation Technology

  2. Retrofitting Inefficient Rooftop Air-Conditioning Units Reduces U.S. Navy Energy Use (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-04-01

    As part of the U.S. Navy's overall energy strategy, the National Renewable Energy Laboratory (NREL) partnered with the Naval Facilities Engineering Command (NAVFAC) to demonstrate market-ready energy efficiency measures, renewable energy generation, and energy systems integration. One such technology - retrofitting rooftop air-conditioning units with an advanced rooftop control system - was identified as a promising source for reducing energy use and costs, and can contribute to increasing energy security.

  3. The Next Generation Air Particle Detectors for the United States Navy

    SciTech Connect (OSTI)

    Robert Hayes and Craig Marianno

    2007-06-24

    Design and testing of the United States Navy’s next generation air particle detector (NGAPD) is presently underway. The NGAPD is intended for use in nuclear applications for the United States Navy and is being designed to detect airborne Co-60 with a reduction in false alarms and improved ease of use. Features being developed include gamma compensation, low maintenance, commercial off-the-shelf electronics, and spectrum simulation for quality assurance and functional testing applications. By supplying a spectrum simulator, the radon stripping algorithm can be running when a simulated anthropogenic source spectrum (e.g., from Co-60 or transuranics) is superimposed on the radon progeny spectrum. This will allow alarm levels to be tested when the air flow is running and the radon stripping algorithm is providing the instrument response output. Modern units evaluate source spectra with the air flow off and the radon spectrum absent thereby not testing the true system performance which comes out of the radon stripping algorithm. Testing results of the preliminary prototype show promise along with computer simulations of source spectra. Primary testing results taken to date include gamma compensation, thermal insults, vibration and spectrum simulation.

  4. Computer Security Incident Handling Guide

    E-Print Network [OSTI]

    Computer Security Incident Handling Guide Recommendationsof the National Institute of Standards Computer Security Division Information Technology Laboratory National Institute of Standards and Technology Gaithersburg, MD Tom Millar United States Computer Emergency Readiness Team National Cyber Security Division

  5. Optimal integrated design of air separation unit and gas turbine block for IGCC systems

    SciTech Connect (OSTI)

    Kamath, R.; Grossman, I.; Biegler, L.; Zitney, S.

    2009-01-01

    The Integrated Gasification Combined Cycle (IGCC) systems are considered as a promising technology for power generation. However, they are not yet in widespread commercial use and opportunities remain to improve system feasibility and profitability via improved process integration. This work focuses on the integrated design of gasification system, air separation unit (ASU) and the gas turbine (GT) block. The ASU supplies oxygen to the gasification system and it can also supply nitrogen (if required as a diluent) to the gas turbine block with minimal incremental cost. Since both GT and the ASU require a source of compressed air, integrating the air requirement of these units is a logical starting point for facility optimization (Smith et al., 1997). Air extraction from the GT can reduce or avoid the compression cost in the ASU and the nitrogen injection can reduce NOx emissions and promote trouble-free operation of the GT block (Wimer et al., 2006). There are several possible degrees of integration between the ASU and the GT (Smith and Klosek, 2001). In the case of 'total' integration, where all the air required for the ASU is supplied by the GT compressor and the ASU is expected to be an elevated-pressure (EP) type. Alternatively, the ASU can be 'stand alone' without any integration with the GT. In this case, the ASU operates at low pressure (LP), with its own air compressor delivering air to the cryogenic process at the minimum energy cost. Here, nitrogen may or may not be injected because of the energy penalty issue and instead, syngas humidification may be preferred. A design, which is intermediate between these two cases, involves partial supply of air by the gas turbine and the remainder by a separate air compressor. These integration schemes have been utilized in some IGCC projects. Examples include Nuon Power Plant at Buggenum, Netherlands (both air and nitrogen integration), Polk Power Station at Tampa, US (nitrogen-only integration) and LGTI at Plaquemine, US (stand-alone). However, there is very little information on systematic assessment of air extraction, nitrogen injection and configuration and operating conditions of the ASU and it is not clear which scheme is optimal for a given IGCC application. In this work, we address the above mentioned problem systematically using mixed-integer optimization. This approach allows the use of various objectives such as minimizing the investment and operating cost or SOx and NOx emissions, maximizing power output or overall efficiency or a weighted combination of these factors. A superstructure is proposed which incorporates all the integration schemes described above. Simplified models for ASU, gas turbine system and steam cycle are used which provide reasonable estimates for performance and cost (Frey and Zhu, 2006). The optimal structural configuration and operating conditions are presented for several case studies and it is observed that the optimal solution changes significantly depending on the specified objective.

  6. Optimal Integrated Design of Air Separation Unit and Gas Turbine Block for IGCC Systems

    SciTech Connect (OSTI)

    Ravindra S. Kamath; Ignacio E. Grossmann; Lorenz T. Biegler; Stephen E. Zitney

    2009-01-01

    The Integrated Gasification Combined Cycle (IGCC) systems are considered as a promising technology for power generation. However, they are not yet in widespread commercial use and opportunities remain to improve system feasibility and profitability via improved process integration. This work focuses on the integrated design of gasification system, air separation unit (ASU) and the gas turbine (GT) block. The ASU supplies oxygen to the gasification system and it can also supply nitrogen (if required as a diluent) to the gas turbine block with minimal incremental cost. Since both GT and the ASU require a source of compressed air, integrating the air requirement of these units is a logical starting point for facility optimization (Smith et al., 1997). Air extraction from the GT can reduce or avoid the compression cost in the ASU and the nitrogen injection can reduce NOx emissions and promote trouble-free operation of the GT block (Wimer et al., 2006). There are several possible degrees of integration between the ASU and the GT (Smith and Klosek, 2001). In the case of 'total' integration, where all the air required for the ASU is supplied by the GT compressor and the ASU is expected to be an elevated-pressure (EP) type. Alternatively, the ASU can be 'stand alone' without any integration with the GT. In this case, the ASU operates at low pressure (LP), with its own air compressor delivering air to the cryogenic process at the minimum energy cost. Here, nitrogen may or may not be injected because of the energy penalty issue and instead, syngas humidification may be preferred. A design, which is intermediate between these two cases, involves partial supply of air by the gas turbine and the remainder by a separate air compressor. These integration schemes have been utilized in some IGCC projects. Examples include Nuon Power Plant at Buggenum, Netherlands (both air and nitrogen integration), Polk Power Station at Tampa, US (nitrogen-only integration) and LGTI at Plaquemine, US (stand-alone). However, there is very little information on systematic assessment of air extraction, nitrogen injection and configuration and operating conditions of the ASU and it is not clear which scheme is optimal for a given IGCC application. In this work, we address the above mentioned problem systematically using mixed-integer optimization. This approach allows the use of various objectives such as minimizing the investment and operating cost or SOx and NOx emissions, maximizing power output or overall efficiency or a weighted combination of these factors. A superstructure is proposed which incorporates all the integration schemes described above. Simplified models for ASU, gas turbine system and steam cycle are used which provide reasonable estimates for performance and cost (Frey and Zhu, 2006). The optimal structural configuration and operating conditions are presented for several case studies and it is observed that the optimal solution changes significantly depending on the specified objective.

  7. Energy Savings and Economics of Advanced Control Strategies for Packaged Air-Conditioning Units with Gas Heat

    SciTech Connect (OSTI)

    Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

    2011-12-31

    Pacific Northwest National Laboratory (PNNL) with funding from the U.S. Department of Energy's Building Technologies Program (BTP) evaluated a number of control strategies that can be implemented in a controller, to improve the operational efficiency of the packaged air conditioning units. The two primary objectives of this research project are: (1) determine the magnitude of energy savings achievable by retrofitting existing packaged air conditioning units with advanced control strategies not ordinarily used for packaged units and (2) estimating what the installed cost of a replacement control with the desired features should be in various regions of the U.S. This document reports results of the study.

  8. Eielson Air Force Base operable unit 2 and other areas record of decision

    SciTech Connect (OSTI)

    Lewis, R.E.; Smith, R.M.

    1994-10-01

    This decision document presents the selected remedial actions and no action decisions for Operable Unit 2 (OU2) at Eielson Air Force Base (AFB), Alaska, chosen in accordance with state and federal regulations. This document also presents the decision that no further action is required for 21 other source areas at Eielson AFB. This decision is based on the administrative record file for this site. OU2 addresses sites contaminated by leaks and spills of fuels. Soils contaminated with petroleum products occur at or near the source of contamination. Contaminated subsurface soil and groundwater occur in plumes on the top of a shallow groundwater table that fluctuates seasonally. These sites pose a risk to human health and the environment because of ingestion, inhalation, and dermal contact with contaminated groundwater. The purpose of this response is to prevent current or future exposure to the contaminated groundwater, to reduce further contaminant migration into the groundwater, and to remediate groundwater.

  9. Operable Unit 1 remedial investigation report, Eielson Air Force Base, Alaska

    SciTech Connect (OSTI)

    Gilmore, T.J.; Fruland, R.M.; Liikala, T.L.

    1994-06-01

    This remedial investigation report for operable Unit 1 (OU-1) at Eielson Air Force Base presents data, calculations, and conclusions as to the nature and extent of surface and subsurface contamination at the eight source areas that make up OU-1. The information is based on the 1993 field investigation result and previous investigations. This report is the first in a set of three for OU-1. The other reports are the baseline risk assessment and feasibility study. The information in these reports will lead to a Record of Decision that will guide and conclude the environmental restoration effort for OU-1 at Eielson Air Force Base. The primary contaminants of concern include fuels and fuel-related contaminants (diesel; benzene, toluene, ethylbenzene, and xylene; total petroleum hydrocarbon; polycyclic aromatic hydrocarbons), maintenance-related solvents and cleaners (volatile chlorinated hydrocarbons such as trichloroothylene), polychlorinated biphenyls, and dichlorodiphenyltrichloroethane (DDT). The origins of contaminants of concern include leaks from storage tanks, drums and piping, and spills. Ongoing operations and past sitewide practices also contribute to contaminants of concern at OU-1 source areas. These include spraying mixed oil and solvent wastes on unpaved roads and aerial spraying of DDT.

  10. Uranium hexafluoride handling. Proceedings

    SciTech Connect (OSTI)

    Not Available

    1991-12-31

    The United States Department of Energy, Oak Ridge Field Office, and Martin Marietta Energy Systems, Inc., are co-sponsoring this Second International Conference on Uranium Hexafluoride Handling. The conference is offered as a forum for the exchange of information and concepts regarding the technical and regulatory issues and the safety aspects which relate to the handling of uranium hexafluoride. Through the papers presented here, we attempt not only to share technological advances and lessons learned, but also to demonstrate that we are concerned about the health and safety of our workers and the public, and are good stewards of the environment in which we all work and live. These proceedings are a compilation of the work of many experts in that phase of world-wide industry which comprises the nuclear fuel cycle. Their experience spans the entire range over which uranium hexafluoride is involved in the fuel cycle, from the production of UF{sub 6} from the naturally-occurring oxide to its re-conversion to oxide for reactor fuels. The papers furnish insights into the chemical, physical, and nuclear properties of uranium hexafluoride as they influence its transport, storage, and the design and operation of plant-scale facilities for production, processing, and conversion to oxide. The papers demonstrate, in an industry often cited for its excellent safety record, continuing efforts to further improve safety in all areas of handling uranium hexafluoride. Selected papers were processed separately for inclusion in the Energy Science and Technology Database.

  11. Scalability and Evolutionary Dynamics of Air Transportation Networks in the United States

    E-Print Network [OSTI]

    Bonnefoy, Philippe

    2007-09-21

    With the growing demand for air transportation and the limited ability to increase capacity at key points in the air transportation system, there are concerns that, in the future, the system will not scale to meet demand. ...

  12. Building Pressure Control in VAV System with Relief Air Fan 

    E-Print Network [OSTI]

    Pang, X.; Liu, M.; Zheng, B.

    2005-01-01

    Building Pressure Control in VAV Systems with Relief Air Fan Xiufeng Pang, Mingsheng Liu, PhD, P.E., Bin Zheng University of Nebraska, Lincoln—ESL 1110 So. 67 th St, Omaha, NE, 68182 Abstract Building pressure control is critical... to energy conservation and indoor air quality by preventing excessive infiltration or exfiltration. In the supply and the return/relief fan Air Handling Unit (AHU) system, better space pressurization can be achieved when return/relief fan operates...

  13. Compressed Gas Cylinder Safe Handling, Use and

    E-Print Network [OSTI]

    Saskatchewan, University of

    Compressed Gas Cylinder Safe Handling, Use and Storage 2012 Workplace Safety and Environmental Protection #12;i College/Unit: Workplace Safety and Environmental Protection Procedure Title: Compressed Gas................................................ 4 7 General Gas Cylinder Information

  14. A study of the housing of United States Air Force married personnel, 1953-1957 

    E-Print Network [OSTI]

    Goforth, Robert Gerald

    1958-01-01

    vill be answered in the study are: 1. What are the general housing conditions at maJor air bases7 2. What have personnel of the Army and Air Force done to help solve their housing problems 3. What are the housing requirements, assets... Force Bases. The Association was established to provi4e mutual aid and financial assistance for the purchase, erection, maintenance, opezstion, ani administration of low cost housing. All Strategic Air ~ personnel were urged to become members of ths...

  15. Control Humidity With Single-Duct, Single-Zone, Constant Air Volume System 

    E-Print Network [OSTI]

    Chen, H.; Deng, S.; Bruner, H. L.; Claridge, D. E.

    2000-01-01

    The lecture hall of the Richardson Petroleum Building at Texas A&M University is a large lecture hall, with a total floor area of approximately 2500 ft^2. The lecture hall was served by a constant air volume (CAV) air handling unit (AHU) which had...

  16. Economic and policy implications of urban air pollution in the United States, 1970 to 2000

    E-Print Network [OSTI]

    Yang, Trent, 1979-

    2004-01-01

    (cont.) over time as pollution levels change. Using these new models, we valued the economic benefit of reduced air pollution due to the Clean Air Act regulations to be over $7 trillion from 1970 to 2000, or 2.1% of aggregate ...

  17. Case Study: The Effective Use of an Extensive Logical rule Based Data Analytics Approach in Establishing Root Cause of Performance Issues in Widespread Deployments of Unitary Space Air Conditioning Units 

    E-Print Network [OSTI]

    Brady, N.

    2013-01-01

    Today a significant percentage of office spaces are air conditioned using widely deployed unitary systems, either Fan Coil Units (FCU) or Variable Air Volume (VAV) boxes, to achieve high degrees of air conditioned zonal control. However establishing...

  18. Report on Preliminary Engineering Study for Installation of an Air Cooled Steam Condenser at Brawley Geothermal Plant, Unit No. 1

    SciTech Connect (OSTI)

    1982-03-01

    The Brawley Geothermal Project comprises a single 10 MW nominal geothermal steam turbine-generator unit which has been constructed and operated by the Southern California Edison Company (SCE). Geothermal steam for the unit is supplied through contract by Union Oil Company which requires the return of all condensate. Irrigation District (IID) purchases the electric power generated and provides irrigation water for cooling tower make-up to the plant for the first-five years of operation, commencing mid-1980. Because of the unavailability of irrigation water from IID in the future, SCE is investigating the application and installation of air cooled heat exchangers in conjunction with the existing wet (evaporative) cooling tower with make-up based on use of 180 gpm (nominal) of the geothermal condensate which may be made available by the steam supplier.

  19. Effects of Air Pollution on Respiratory Disease Asthma, closely associated with air pollution, affects nearly 15 million people in the United States, one-third of them

    E-Print Network [OSTI]

    Schladow, S. Geoffrey

    Effects of Air Pollution on Respiratory Disease Asthma, closely associated with air pollution as a greater understanding of the types of air pollutants that cause the most harm. Seminal findings, supporting a proposed update to existing air quality standards. Air pollutant ozone causes childhood asthma

  20. Vacuum Vessel Remote Handling

    E-Print Network [OSTI]

    FIRE Vacuum Vessel and Remote Handling Overview B. Nelson, T. Burgess, T. Brown, H-M Fan, G. Jones #12;13 July 2002 Snowmass Review: FIRE Vacuum Vessel and Remote Handling 2 Presentation Outline · Vacuum Vessel - Design requirements - Design concept and features - Analysis to date - Status and summary

  1. Classifications, Social Contracts, Obligations, Civil Rights, and the Supreme Court: Sutton v. United Air Lines

    E-Print Network [OSTI]

    Turnbull, H. Rutherford

    2001-01-01

    assist the person to mitigate the effects of the disability. Fourth, what kind of civil rights protections can people with disabilities expect from law anid society today? That's a very current and controversial question. What does the United States... Supreme Court have to say in answer to these four questions? As one of the nation's three most powerful policy-making bodies (the president and Con- gress being the other two), the relevant views of a majority of the Court certainlv warrant our attention...

  2. United States Office of Radiation and EP A Environmental Protection Indoor Air August 1997

    Office of Legacy Management (LM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefield Municipal Gas &SCE-SessionsSouthReport for the WeldonB10081278 United States Government.EP A

  3. 3-50 A classroom is to be air-conditioned using window air-conditioning units. The cooling load is due to people, lights, and heat transfer through the walls and the windows. The number of 5-kW window air

    E-Print Network [OSTI]

    Bahrami, Majid

    3-19 3-50 A classroom is to be air-conditioned using window air-conditioning units. The cooling.17 3-51 The lighting energy consumption of a storage room is to be reduced by installing motion sensors lamps)(60 W/lamp )(3285 hours/year) = 4730 kWh/year Cost Savings = (Energy Savings)(Unit cost of energy

  4. United States Environmental Protection Agency Office of Radiation and Indoor Air (6608J) EPA 402-F-12-001 | September 2013 www.epa.gov/radiation/laws/190

    E-Print Network [OSTI]

    United States Environmental Protection Agency Office of Radiation and Indoor Air (6608J) EPA 402-F-12-001 | September 2013 www.epa.gov/radiation/laws/190 "Environmental Radiation Protection Standards discussion about whether to revise the Environmental Radiation Protection Standards for Nuclear Power

  5. CERTIFICATION OF WASTE GENERATOR SITES 2009 EPA WIPP RECERTIFICATION FACT SHEET United States Environmental Protection Agency | Office of Air and Radiation (6608J) | June 2009

    E-Print Network [OSTI]

    CERTIFICATION OF WASTE GENERATOR SITES 2009 EPA WIPP RECERTIFICATION FACT SHEET United States Environmental Protection Agency | Office of Air and Radiation (6608J) | June 2009 http://www.epa.gov/radiation/wipp to the Waste Isolation Pilot Plant (WIPP) is characterized by transuranic (TRU) waste generator sites operating

  6. PERFORMANCE ASSESSMENT 2009 EPA WIPP RECERTIFICATION FACT SHEET United States Environmental Protection Agency | Office of Air and Radiation (6608J) | June 2009

    E-Print Network [OSTI]

    PERFORMANCE ASSESSMENT 2009 EPA WIPP RECERTIFICATION FACT SHEET United States Environmental Protection Agency | Office of Air and Radiation (6608J) | June 2009 http://www.epa.gov/radiation/wipp the Waste Isolation Pilot Plant (WIPP) to the accessible environment over a 10,000-year period. The WIPP PA

  7. HYDROGEOLOGY 2009 EPA WIPP RECERTIFICATION FACT SHEET United States Environmental Protection Agency | Office of Air and Radiation (6608J) | June 2009

    E-Print Network [OSTI]

    HYDROGEOLOGY 2009 EPA WIPP RECERTIFICATION FACT SHEET United States Environmental Protection Agency | Office of Air and Radiation (6608J) | June 2009 http://www.epa.gov/radiation/wipp/index.html HYDROGEOLOGY as hydrogeology. WIPP hydrogeology Hydrogeologic studies for WIPP have been conducted to understand the rates

  8. WIPP TRANSURANIC WASTE INVENTORY 2009 EPA WIPP RECERTIFICATION FACT SHEET United States Environmental Protection Agency | Office of Air and Radiation (6608J) | June 2009

    E-Print Network [OSTI]

    WIPP TRANSURANIC WASTE INVENTORY 2009 EPA WIPP RECERTIFICATION FACT SHEET United States Environmental Protection Agency | Office of Air and Radiation (6608J) | June 2009 http://www.epa.gov/radiation/wipp/index.html WIPP TRANSURANIC WASTE INVENTORY How has the WIPP transuranic (TRU) waste inventory changed since

  9. MAGNESIUM OXIDE AN ENGINEERED BARRIER 2009 EPA WIPP RECERTIFICATION FACT SHEET United States Environmental Protection Agency | Office of Air and Radiation (6608J) | June 2009

    E-Print Network [OSTI]

    MAGNESIUM OXIDE ­ AN ENGINEERED BARRIER 2009 EPA WIPP RECERTIFICATION FACT SHEET United States Environmental Protection Agency | Office of Air and Radiation (6608J) | June 2009 http://www.epa.gov/radiation/wipp/index.html MAGNESIUM OXIDE ­ AN ENGINEERED BARRIER Why is MgO Used At WIPP? The U.S. Department of Energy (DOE

  10. Best Practice for Energy Efficient Cleanrooms: Fan-FilterUnits

    SciTech Connect (OSTI)

    Xu, Tengfang

    2005-06-15

    The HVAC systems in cleanrooms may use 50 percent or more of the total cleanroom energy use. Fan energy use accounts for a significant portion (e.g., over 50%) of the HVAC energy use in cleanrooms such as ISO Classes 3, 4, or 5. Three types of air-handling systems for recirculating airflows are commonly used in cleanrooms: (1) fan-tower systems with pressurized plenum, (2) ducted HEPA systems with distributed-fans, and (3) systems with fan-filter units. Because energy efficiency of the recirculation systems could vary significantly from system type to system type, optimizing aerodynamic performance in air recirculation systems appears to be a useful approach to improve energy efficiency in cleanrooms. Providing optimal airflows through careful planning, design and operation, including air change rate, airflow uniformity, and airflow speed, is important for controlling particle contamination in cleanrooms. In practice, the use of fan-filter units (FFUs) in the air-handling system is becoming more and more popular because of this type of system may offer a number of advantages. Often modular and portable than traditional recirculation airflow systems, FFUs are easier to install, and can be easily controlled and monitored to maintain filtration performance. Energy efficiency of air handling systems using fan-filter units can, however, be lower than their counterparts and may vary significantly from system to system because of the difference in energy performance, airflow paths, and the operating conditions of FFUs.

  11. The horizontal desalination unit described herein utilizes the humidification-dehumidification process to purify water using air as a carrier gas. The temperature required to drive the process is low enough that

    E-Print Network [OSTI]

    The horizontal desalination unit described herein utilizes the humidification enough that waste heat from a fuel combustion or solar collectors can be used. A unit in which air horizontal units, determine the efficiency of operation, and isolate ways of improving future units

  12. Direct-Expansion Air-Conditioning System Performance in Low Humidity Applications: A Case Study 

    E-Print Network [OSTI]

    Khattar, M. K.; Keebaugh, D.

    1987-01-01

    . Historic energy-use data and field-measured performance data are analyzed. The importance of certain design and operating parameters such as indoor airflow quantity, cooling coil apparatus dew-point temperature and the air-handling unit's fan operating...

  13. Application of WRF/Chem-MADRID for real-time air quality forecasting over the Southeastern United States

    E-Print Network [OSTI]

    Zhang, Yang

    States Ming-Tung Chuang a , Yang Zhang a,*, Daiwen Kang b a Air Quality Forecasting Lab, North Carolina on a three-dimensional air quality model provides a powerful tool to forecast air quality and advise, inaccuracies in simulated meteorological variables such as 2-m temperature, 10-m wind speed, and precipitation

  14. Updated greenhouse gas and criteria air pollutant emission factors and their probability distribution functions for electricity generating units

    SciTech Connect (OSTI)

    Cai, H.; Wang, M.; Elgowainy, A.; Han, J.

    2012-07-06

    Greenhouse gas (CO{sub 2}, CH{sub 4} and N{sub 2}O, hereinafter GHG) and criteria air pollutant (CO, NO{sub x}, VOC, PM{sub 10}, PM{sub 2.5} and SO{sub x}, hereinafter CAP) emission factors for various types of power plants burning various fuels with different technologies are important upstream parameters for estimating life-cycle emissions associated with alternative vehicle/fuel systems in the transportation sector, especially electric vehicles. The emission factors are typically expressed in grams of GHG or CAP per kWh of electricity generated by a specific power generation technology. This document describes our approach for updating and expanding GHG and CAP emission factors in the GREET (Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation) model developed at Argonne National Laboratory (see Wang 1999 and the GREET website at http://greet.es.anl.gov/main) for various power generation technologies. These GHG and CAP emissions are used to estimate the impact of electricity use by stationary and transportation applications on their fuel-cycle emissions. The electricity generation mixes and the fuel shares attributable to various combustion technologies at the national, regional and state levels are also updated in this document. The energy conversion efficiencies of electric generating units (EGUs) by fuel type and combustion technology are calculated on the basis of the lower heating values of each fuel, to be consistent with the basis used in GREET for transportation fuels. On the basis of the updated GHG and CAP emission factors and energy efficiencies of EGUs, the probability distribution functions (PDFs), which are functions that describe the relative likelihood for the emission factors and energy efficiencies as random variables to take on a given value by the integral of their own probability distributions, are updated using best-fit statistical curves to characterize the uncertainties associated with GHG and CAP emissions in life-cycle modeling with GREET.

  15. Solid waste handling

    SciTech Connect (OSTI)

    Parazin, R.J.

    1995-05-31

    This study presents estimates of the solid radioactive waste quantities that will be generated in the Separations, Low-Level Waste Vitrification and High-Level Waste Vitrification facilities, collectively called the Tank Waste Remediation System Treatment Complex, over the life of these facilities. This study then considers previous estimates from other 200 Area generators and compares alternative methods of handling (segregation, packaging, assaying, shipping, etc.).

  16. Sectional device handling tool

    DOE Patents [OSTI]

    Candee, Clark B. (Monroeville, PA)

    1988-07-12

    Apparatus for remotely handling a device in an irradiated underwater environment includes a plurality of tubular sections interconnected end-to-end to form a handling structure, the bottom section being adapted for connection to the device. A support section is connected to the top tubular section and is adapted to be suspended from an overhead crane. Each section is flanged at its opposite ends. Axially retractable bolts in each bottom flange are threadedly engageable with holes in the top flange of an adjacent section, each bolt being biased to its retracted position and retained in place on the bottom flange. Guide pins on each top flange cooperate with mating holes on adjacent bottom flanges to guide movement of the parts to the proper interconnection orientation. Each section carries two hydraulic line segments provided with quick-connect/disconnect fittings at their opposite ends for connection to the segments of adjacent tubular sections upon interconnection thereof to form control lines which are connectable to the device and to an associated control console.

  17. Air pollution and early deaths in the United States : attribution of PM?.? exposure to emissions species, time, location and sector

    E-Print Network [OSTI]

    Dedoussi, Irene Constantina

    2014-01-01

    Combustion emissions constitute the largest source of anthropogenic emissions in the US. They lead to the degradation of air quality and human health, by contributing to the formation of fine particulate matter (PM2 .5 ), ...

  18. Air Pollution Control Regulations: No. 13- Particulate Emissions from Fossil Fuel Fired Steam or Hot Water Generating Units (Rhode Island)

    Broader source: Energy.gov [DOE]

    The purpose of this regulation is to limit emissions of particulate matter from fossil fuel fired and wood-fired steam or hot water generating units.

  19. EMISSIONS TO AIR OPERATIONAL PROCEDURE

    E-Print Network [OSTI]

    Harman, Neal.A.

    PURPOSE: To minimise emissions and discharges to air from boilers, fume cupboards, air conditioning Act 1993. SCOPE: All air-conditioning and refrigeration equipment METHOD: Air-conditioning or fluorinated greenhouse gases (air conditioning units, refrigeration units etc.) 2. Several approved

  20. Source evaluation report phase 2 investigation: Limited field investigation. Final report: United States Air Force Environmental Restoration Program, Eielson Air Force Base, Alaska

    SciTech Connect (OSTI)

    Not Available

    1994-10-01

    This report describes the limited field investigation work done to address issues and answer unresolved questions regarding a collection of potential contaminant sources at Eielson Air Force Base (AFB), near Fairbanks, Alaska. These sources were listed in the Eielson AFB Federal Facility Agreement supporting the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) cleanup of the base. The limited field investigation began in 1993 to resolve all remaining technical issues and provide the data and analysis required to evaluate the environmental hazard associated with these sites. The objective of the limited field investigation was to allow the remedial project managers to sort each site into one of three categories: requiring remedial investigation/feasibility study, requiring interim removal action, or requiring no further remedial action.

  1. Unvented Drum Handling Plan

    SciTech Connect (OSTI)

    MCDONALD, K.M.

    2000-08-01

    This drum-handling plan proposes a method to deal with unvented transuranic drums encountered during retrieval of drums. Finding unvented drums during retrieval activities was expected, as identified in the Transuranic (TRU) Phase I Retrieval Plan (HNF-4781). However, significant numbers of unvented drums were not expected until excavation of buried drums began. This plan represents accelerated planning for management of unvented drums. A plan is proposed that manages unvented drums differently based on three categories. The first category of drums is any that visually appear to be pressurized. These will be vented immediately, using either the Hanford Fire Department Hazardous Materials (Haz. Mat.) team, if such are encountered before the facilities' capabilities are established, or using internal capabilities, once established. To date, no drums have been retrieved that showed signs of pressurization. The second category consists of drums that contain a minimal amount of Pu isotopes. This minimal amount is typically less than 1 gram of Pu, but may be waste-stream dependent. Drums in this category are assayed to determine if they are low-level waste (LLW). LLW drums are typically disposed of without venting. Any unvented drums that assay as TRU will be staged for a future venting campaign, using appropriate safety precautions in their handling. The third category of drums is those for which records show larger amounts of Pu isotopes (typically greater than or equal to 1 gram of Pu). These are assumed to be TRU and are not assayed at this point, but are staged for a future venting campaign. Any of these drums that do not have a visible venting device will be staged awaiting venting, and will be managed under appropriate controls, including covering the drums to protect from direct solar exposure, minimizing of container movement, and placement of a barrier to restrict vehicle access. There are a number of equipment options available to perform the venting. The preferred option is to use equipment provided by a commercial vendor during the first few years of retrieval and venting. This is based on a number of reasons. First, retrieval funding is uncertain. Using a commercial vendor will allow DOE-RL to avoid the investment and maintenance costs if retrieval is not funded. Second, when funding can be identified, retrieval will likely be performed with minimal initial throughput and intermittent operations. Again, costs can be saved by using contracted vendor services only as needed, rather than supporting Hanford equipment full time. When full-scale retrieval begins and the number of drums requiring venting increases significantly, then use of the Hanford container venting system (CVS) should be considered.

  2. Design Method for the Heating/Cooling Coil in the AHU Based on Fuzzy Logic - Part Two: Design of the Minimum Heat-Exchanging Unit 

    E-Print Network [OSTI]

    Zhang, J.; Chen, Y.; Liang, Z.

    2006-01-01

    Considering a heating/cooling coil with adjustable heat-exchange area, an unequal type is put forward in this paper. Aiming at the application of such heat exchanger in an air-handling unit, restriction conditions are given for the minimum heat...

  3. DISPOSAL CONTAINER HANDLING SYSTEM DESCRIPTION DOCUMENT

    SciTech Connect (OSTI)

    E. F. Loros

    2000-06-30

    The Disposal Container Handling System receives and prepares new disposal containers (DCs) and transfers them to the Assembly Transfer System (ATS) or Canister Transfer System (CTS) for loading. The system receives the loaded DCs from ATS or CTS and welds the lids. When the welds are accepted the DCs are termed waste packages (WPs). The system may stage the WP for later transfer or transfer the WP directly to the Waste Emplacement/Retrieval System. The system can also transfer DCs/WPs to/from the Waste Package Remediation System. The Disposal Container Handling System begins with new DC preparation, which includes installing collars, tilting the DC upright, and outfitting the container for the specific fuel it is to receive. DCs and their lids are staged in the receipt area for transfer to the needed location. When called for, a DC is put on a cart and sent through an airlock into a hot cell. From this point on, all processes are done remotely. The DC transfer operation moves the DC to the ATS or CTS for loading and then receives the DC for welding. The DC welding operation receives loaded DCs directly from the waste handling lines or from interim lag storage for welding of the lids. The welding operation includes mounting the DC on a turntable, removing lid seals, and installing and welding the inner and outer lids. After the weld process and non-destructive examination are successfully completed, the WP is either staged or transferred to a tilting station. At the tilting station, the WP is tilted horizontally onto a cart and the collars removed. The cart is taken through an air lock where the WP is lifted, surveyed, decontaminated if required, and then moved into the Waste Emplacement/Retrieval System. DCs that do not meet the welding non-destructive examination criteria are transferred to the Waste Package Remediation System for weld preparation or removal of the lids. The Disposal Container Handling System is contained within the Waste Handling Building System. This includes the primary hot cell bounded by the receiving area and WP transport exit air locks; and isolation doors at ATS, CTS, and Waste Package Remediation. The hot cell includes areas for welding, various staging, tilting, and WP transporter loading. There are associated operating galleries and equipment maintenance areas outside the hot cell. These areas operate concurrently to accommodate the DC/WP throughput rates and support system maintenance. The new DC preparation area is located in an unshielded structure. The handling equipment includes DC/WP bridge cranes, tilting stations, and horizontal transfer carts. The welding area includes DC/WP welders and staging stations. Welding operations are supported by remotely operated equipment including a bridge crane and hoists, welder jib cranes, welding turntables, and manipulators. WP transfer includes a transfer/decontamination and transporter load area. The transfer operations are supported by a remotely operated horizontal lifting system, decontamination system, decontamination and inspection manipulator, and a WP horizontal transfer cart. All handling operations are supported by a suite of fixtures including collars, yokes, lift beams, and lid attachments. Remote equipment is designed to facilitate decontamination and maintenance. Interchangeable components are provided where appropriate. Set-aside areas are included, as required, for fixtures and tooling to support off-normal and recovery operations. Semi-automatic, manual, and backup control methods support normal, maintenance, and recovery operations. The system interfaces with the ATS and CTS to provide empty and receive loaded DCs. The Waste Emplacement/Retrieval System interfaces are for loading/unloading WPs on/from the transporter. The system also interfaces with the Waste Package Remediation System for DC/WP repair. The system is housed, shielded, supported, and has ventilation boundaries by the Waste Handling Building (WHB). The system is ventilated by the WHB Ventilation System, which in conjunction with ventilation boundaries ensure that ai

  4. Reduction of air in-leakage and flue gas by-passing in the penthouse of Duke Power-Marshall Unit No. 4

    SciTech Connect (OSTI)

    Campbell, R.; Rush, T.

    1995-12-31

    After a year of operation, the penthouse was inspected and found to be {open_quotes}lightly dusted{close_quotes} with barely sufficient accumulation to show footprints. This is contrasted with previous five foot deep ash dunes. The savings in maintenance repairs are estimated at $65,000 for vacuuming that was not required, and $80,000 in maintenance personnel weld repairs. The history of repairs was such that vacuuming and weld repair costs were predictable, and before the IOSMEMBRANE{reg_sign} installation, always expected as recurring maintenance costs. The heat rate improvement of reducing air in-leakage is well known, and significant. The principal quantified savings are in reduced maintenance costs, more expedient repairs (reduced cool down time for repairs in the penthouse), and safety. The heat rate improvements, though not quantified yet, are expected to be significant. The success of the ISOMEMBRANE{reg_sign} on Unit No. 4 has resulted in similar plans for Unit No. 3 and other units in the Duke Power system.

  5. Contact-Handled and Remote-Handled Transuranic Waste Packaging

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2011-08-09

    Provides specific instructions for packaging and/or repackaging contact-handled transuranic (CH-TRU) and remote-handled transuranic (RH-TRU) waste in a manner consistent with DOE O 435.1, Radioactive Waste Management, DOE M 435.1-1 Chg 1, Radioactive Waste Management Manual, CH-TRU and RH-TRU waste transportation requirements, and Waste Isolation Pilot Plant (WIPP) programmatic requirements. Does not cancel/supersede other directives.

  6. Tritium handling in vacuum systems

    SciTech Connect (OSTI)

    Gill, J.T. [Monsanto Research Corp., Miamisburg, OH (United States). Mound Facility; Coffin, D.O. [Los Alamos National Lab., NM (United States)

    1986-10-01

    This report provides a course in Tritium handling in vacuum systems. Topics presented are: Properties of Tritium; Tritium compatibility of materials; Tritium-compatible vacuum equipment; and Tritium waste treatment.

  7. WEAR RESISTANT ALLOYS FOR COAL HANDLING EQUIPMENT

    E-Print Network [OSTI]

    Bhat, M.S.

    2011-01-01

    Proceedings of the Conference on Coal Feeding Systems, HeldWear Resistant Alloys for Coal Handling Equipment", proposalWear Resistant Alloys for Coal Handling Equi pment". The

  8. Handling and Packaging a Potentially Radiologically Contaminated...

    Office of Environmental Management (EM)

    Handling and Packaging a Potentially Radiologically Contaminated Patient Handling and Packaging a Potentially Radiologically Contaminated Patient The purpose of this procedure is...

  9. ETEC - Radioactive Handling Materials Facility (RMHF) Leachfield...

    Office of Environmental Management (EM)

    - Radioactive Handling Materials Facility (RMHF) Leachfield ETEC - Radioactive Handling Materials Facility (RMHF) Leachfield January 1, 2014 - 12:00pm Addthis US Department of...

  10. Life cycle air quality impacts of conventional and alternative light-duty transportation in the United States

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Tessum, Christopher W.; Hill, Jason D.; Marshall, Julian D.

    2014-12-30

    Commonly considered strategies for reducing the environmental impact of light-duty transportation include using alternative fuels and improving vehicle fuel economy. We evaluate the air quality-related human health impacts of 10 such options, including the use of liquid biofuels, diesel, and compressed natural gas (CNG) in internal combustion engines; the use of electricity from a range of conventional and renewable sources to power electric vehicles (EVs); and the use of hybrid EV technology. Our approach combines spatially, temporally, and chemically detailed life cycle emission inventories; comprehensive, fine-scale state-of-the-science chemical transport modeling; and exposure, concentration–response, and economic health impact modeling for ozonemore »(O3) and fine particulate matter (PM2.5). We find that powering vehicles with corn ethanol or with coal-based or “grid average” electricity increases monetized environmental health impacts by 80% or more relative to using conventional gasoline. Conversely, EVs powered by low-emitting electricity from natural gas, wind, water, or solar power reduce environmental health impacts by 50% or more. Consideration of potential climate change impacts alongside the human health outcomes described here further reinforces the environmental preferability of EVs powered by low-emitting electricity relative to gasoline vehicles.« less

  11. Life cycle air quality impacts of conventional and alternative light-duty transportation in the United States

    SciTech Connect (OSTI)

    Tessum, Christopher W.; Hill, Jason D.; Marshall, Julian D.

    2014-12-30

    Commonly considered strategies for reducing the environmental impact of light-duty transportation include using alternative fuels and improving vehicle fuel economy. We evaluate the air quality-related human health impacts of 10 such options, including the use of liquid biofuels, diesel, and compressed natural gas (CNG) in internal combustion engines; the use of electricity from a range of conventional and renewable sources to power electric vehicles (EVs); and the use of hybrid EV technology. Our approach combines spatially, temporally, and chemically detailed life cycle emission inventories; comprehensive, fine-scale state-of-the-science chemical transport modeling; and exposure, concentration–response, and economic health impact modeling for ozone (O3) and fine particulate matter (PM2.5). We find that powering vehicles with corn ethanol or with coal-based or “grid average” electricity increases monetized environmental health impacts by 80% or more relative to using conventional gasoline. Conversely, EVs powered by low-emitting electricity from natural gas, wind, water, or solar power reduce environmental health impacts by 50% or more. Consideration of potential climate change impacts alongside the human health outcomes described here further reinforces the environmental preferability of EVs powered by low-emitting electricity relative to gasoline vehicles.

  12. Uranium hexafluoride: A manual of good handling practices. Revision 7

    SciTech Connect (OSTI)

    NONE

    1995-01-01

    The United States Enrichment Corporation (USEC) is continuing the policy of the US Department of Energy (DOE) and its predecessor agencies in sharing with the nuclear industry their experience in the area of uranium hexafluoride (UF{sub 6}) shipping containers and handling procedures. The USEC has reviewed Revision 6 or ORO-651 and is issuing this new edition to assure that the document includes the most recent information on UF{sub 6} handling procedures and reflects the policies of the USEC. This manual updates the material contained in earlier issues. It covers the essential aspects of UF{sub 6} handling, cylinder filling and emptying, general principles of weighing and sampling, shipping, and the use of protective overpacks. The physical and chemical properties of UF{sub 6} are also described. The procedures and systems described for safe handling of UF{sub 6} presented in this document have been developed and evaluated during more than 40 years of handling vast quantities of UF{sub 6}. With proper consideration for its nuclear properties, UF{sub 6} may be safely handled in essentially the same manner as any other corrosive and/or toxic chemical.

  13. Safe Handling of Fresh Oranges 

    E-Print Network [OSTI]

    Scott, Amanda

    2008-09-05

    hands before and after handling food and after touching raw meat, changing a diaper, using the restroom, handling a pet or touching anything that could contaminate your hands. Then dry your hands with a paper towel. Wash and sanitize all the food... for raw meats and oranges, or wash and sanitize them between foods. This will prevent any patho- gens on the raw meat from being transferred to the oranges. Refrigerate leftover cut and/or peeled oranges within 2 hours. If they are left unrefrigerated...

  14. Investigation of Feasibility of All-Fresh Air Supply in an All-Air System 

    E-Print Network [OSTI]

    Wang, J.; Yan, Z.

    2006-01-01

    The feasibility of an all-fresh air supply in an all-air system is investigated in theory, and the problem of AHU-handling air in low efficiency in summer and winter conditions is analyzed. The air supply temperature is almost up to standards when a...

  15. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01

    integrated with an air conditioner unit and air/water heatan air conditioner unit and air/water heat exchanger Source:system and a standard air/water heat exchanger. Figure A-

  16. United_Cool_Air.pdf

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LIST OF APPLICABLEStatutoryin theNuclear Energy Research andofRod Beever

  17. Low Stress Cattle Handling in Dairy Environments 

    E-Print Network [OSTI]

    Villarino, Mario A.

    2009-05-04

    Using low-stress methods of handling dairy cattle is efficient in terms of time and labor. This publication explains how cattle's natural instincts affect their responses, and ways handlers can use that knowledge to make handling easier and less...

  18. Assessment of the Effect of Air Pollution Controls on Trends in Shortwave Radiation over the United States from 1995 through 2010 from Multiple Observation Networks

    SciTech Connect (OSTI)

    Gan, Chuen-Meei; Pleim, Jonathan; Mathur, Rohit; Hogrefe, Christian; Long, Charles N.; Xing, Jia; Roselle, Shawn; Wei, Chao

    2014-02-14

    Long term datasets of total (all-sky) and clear-sky downwelling shortwave (SW) radiation, cloud cover fraction (cloudiness) and aerosol optical depth (AOD) are analyzed together with aerosol concentration from several networks (e.g. SURFRAD, CASTNET, IMPROVE and ARM) in the United States (US). Seven states with varying climatology are selected to better understand the effect of aerosols and clouds on SW radiation. This analysis aims to test the hypothesis that the reductions in anthropogenic aerosol burden resulting from substantial reductions in emissions of sulfur dioxide and nitrogen oxides over the past 15 years across the US has caused an increase in surface SW radiation. We show that the total and clear-sky downwelling SW radiation from seven sites have increasing trends except Penn State which shows no tendency in clear-sky SW radiation. After investigating several confounding factors, the causes can be due to the geography of the site, aerosol distribution, heavy air traffic and increasing cloudiness. Moreover, we assess the relationship between total column AOD with surface aerosol concentration to test our hypothesis. In our findings, the trends of clear-sky SW radiation, AOD, and aerosol concentration from the sites in eastern US agree well with our hypothesis. However, the sites in western US demonstrate increasing AOD associated with mostly increasing trends in surface aerosol concentration. At these sites, the changes in aerosol burden and/or direct aerosol effects alone cannot explain the observed changes in SW radiation, but other factors need to be considered such as cloudiness, aerosol vertical profiles and elevated plumes.

  19. Unequal State Air Pollution: Adopting and Adapting to State Clean Air Policy

    E-Print Network [OSTI]

    Glasgow, Derek John

    2015-05-31

    context can limit its ability to regulate air pollution. These factors contribute to the unequal protection of air quality across the United States....

  20. Safe Handling of Fresh Cantaloupe 

    E-Print Network [OSTI]

    Scott, Amanda

    2008-09-05

    , using the restroom, handling a pet or touching anything that could contaminate your hands. Then dry your hands with a paper towel. Wash and sanitize all food preparation areas and utensils with a solution of 1 teaspoon chlo- rine bleach in 1 quart... of water. This includes your fruit/vegetable brush. Wash all whole cantaloupes thoroughly in a clean sink under clean, running water. Use a clean and sanitized fruit/vegetable brush to vigorously scrub the outside of the cantaloupe under running...

  1. Safe Handling of Fresh Tomatoes 

    E-Print Network [OSTI]

    Scott, Amanda

    2008-09-05

    before you eat or prepare them. Before handling fresh tomatoes, wash your hands with hot, soapy water for 20 seconds. Dry them with a paper towel. Wash and sanitize all food preparation areas and utensils with a solution of 1 teaspoon of chlo- rine..., soaps or bleach to wash fresh tomatoes. These chemicals may change the flavor and could be poisonous. When cutting or chopping tomatoes, use separate cutting boards and utensils for raw meats and fresh tomatoes, or wash and sanitize them between...

  2. Retrofit Air Preheat Economics 

    E-Print Network [OSTI]

    Goolsbee, J. A.

    1981-01-01

    Retrofit air preheat systems are the most reliable and efficient means to effect significant energy conservation for large existing industrial furnaces. Units can be quickly installed without a lengthy shutdown, and the furnace efficiency can...

  3. Transfer Area Mechanical Handling Calculation

    SciTech Connect (OSTI)

    B. Dianda

    2004-06-23

    This calculation is intended to support the License Application (LA) submittal of December 2004, in accordance with the directive given by DOE correspondence received on the 27th of January 2004 entitled: ''Authorization for Bechtel SAX Company L.L. C. to Include a Bare Fuel Handling Facility and Increased Aging Capacity in the License Application, Contract Number DE-AC28-01R W12101'' (Arthur, W.J., I11 2004). This correspondence was appended by further Correspondence received on the 19th of February 2004 entitled: ''Technical Direction to Bechtel SAIC Company L.L. C. for Surface Facility Improvements, Contract Number DE-AC28-OIRW12101; TDL No. 04-024'' (BSC 2004a). These documents give the authorization for a Fuel Handling Facility to be included in the baseline. The purpose of this calculation is to establish preliminary bounding equipment envelopes and weights for the Fuel Handling Facility (FHF) transfer areas equipment. This calculation provides preliminary information only to support development of facility layouts and preliminary load calculations. The limitations of this preliminary calculation lie within the assumptions of section 5 , as this calculation is part of an evolutionary design process. It is intended that this calculation is superseded as the design advances to reflect information necessary to support License Application. The design choices outlined within this calculation represent a demonstration of feasibility and may or may not be included in the completed design. This calculation provides preliminary weight, dimensional envelope, and equipment position in building for the purposes of defining interface variables. This calculation identifies and sizes major equipment and assemblies that dictate overall equipment dimensions and facility interfaces. Sizing of components is based on the selection of commercially available products, where applicable. This is not a specific recommendation for the future use of these components or their related manufacturer. A component produced by one manufacturer certainly varies dimensionally from a similar product produced by a different manufacturer. The internal envelope dimensions are dependent on the selection of the individual components. The external envelope dimensions, as well as, key interface dimensions are established within this calculation and are to be treated as bounding dimensions.

  4. CANISTER HANDLING FACILITY DESCRIPTION DOCUMENT

    SciTech Connect (OSTI)

    J.F. Beesley

    2005-04-21

    The purpose of this facility description document (FDD) is to establish requirements and associated bases that drive the design of the Canister Handling Facility (CHF), which will allow the design effort to proceed to license application. This FDD will be revised at strategic points as the design matures. This FDD identifies the requirements and describes the facility design, as it currently exists, with emphasis on attributes of the design provided to meet the requirements. This FDD is an engineering tool for design control; accordingly, the primary audience and users are design engineers. This FDD is part of an iterative design process. It leads the design process with regard to the flowdown of upper tier requirements onto the facility. Knowledge of these requirements is essential in performing the design process. The FDD follows the design with regard to the description of the facility. The description provided in this FDD reflects the current results of the design process.

  5.  Underfloor air distribution (UFAD) cost study: analysis of first cost tradeoffs in UFAD systems

    E-Print Network [OSTI]

    Webster, Tom; Benedek, Corinne; Bauman, Fred

    2006-01-01

    Energy Savings • Air Handling Savings • HVAC Churn • Tenantand Workstation Churn Qualitative Benefits: Benefits thatCarpeting Carpet selection Churn Waste per churn Usable life

  6. Appendix 5 Handling of Fourth-Year Appraisals Appendix 5 Handling of Fourth-Year Appraisals

    E-Print Network [OSTI]

    Talley, Lynne D.

    Appendix 5 Handling of Fourth-Year Appraisals App. 5-1 Appendix 5 ­ Handling of Fourth-Year Appraisals An appraisal is normally conducted in the fourth year of an Assistant-level candidate votes, click "Vote" to open the Department Vote form. #12;Appendix 5 Handling of Fourth-Year Appraisals

  7. " Million Housing Units, Final...

    U.S. Energy Information Administration (EIA) Indexed Site

    3 Air Conditioning in U.S. Homes, by Year of Construction, 2009" " Million Housing Units, Final" ,,"Year of Construction" ,"Total U.S.1 (millions)" ,,"Before 1940","1940 to...

  8. NOx control technology requirements under the United States 1990 Clean Air Act amendments compared to those in selected pacific rim countries. Report for September 1993-September 1994

    SciTech Connect (OSTI)

    Miller, C.A.; Hall, R.E.; Stern, R.D.

    1994-09-01

    The paper compares nitrogen oxide (NOx) control technology requirements under the U.S. 1990 Clean Air Act Amendments (CAAAs) with those in selected Pacific Rim countries. The CAAAs require reduction of NOx emissions under Titles I (requiring control of NOx from all source types for the purpose of attaining ambient air quality standards for NOx and ozone) and IV (requiring control of NOx from coal-fired utility boilers for the reduction of acid rain precursors). Title IV sets national emission standards for dry-bottom wall-fired and tangentially fired boilers based on low NOx burner technology, defined by EPA to include separated overfire air. Emission standards for other boiler types are to be promulgated by 1997. Title I controls, based on reductions necessary to reduce local and regional ambient levels of NOx and ozone, involve Reasonably Available Control Technology (RACT) as defined by EPA`s Office of Air Quality Planning and Standards; however, emission levels are set by the states according to local conditions. Technologies defined as RACT include low NOx burner technology, selective non-catalytic modifications, and selective catalytic reduction. These and other combustion modifications and flue gas treatment technologies are described.

  9. Inorganic hazardous air pollutants before and after a limestone flue gas desulfurization system as a function of <10 micrometer particle sizes and unit load

    SciTech Connect (OSTI)

    Maxwell, D.P.; Williams, W.A.; Flora, H.B. II [Radian Corp., Austin, TX (United States)

    1995-12-31

    Radian Corporation collected size-fractionated particulate samples from stack gas at a unit burning high sulfur coal with a venturi scrubber FGD system. Independent sample fractions were collected under high-load and low-load operating conditions and subjected to various techniques designed to measure the total composition and surface-extractable concentrations of selected trace elements. The relationships between unit load, particle-size distribution, total composition, and surface-extractable inorganic species are reported and compared to show the availability of trace elements relevant to potential health risks from flue gas particulate emissions.

  10. Hazardous Materials Handling High Pressure Cylinders

    E-Print Network [OSTI]

    Boynton, Walter R.

    NOT FILL CYLINDERS #12;The US Dept. of Labor, Occupational Safety Health Administration (OSHA) regulates do propose a risk,through proper handling,storage, use and filling the risk may be reduced

  11. User interface handles for web objects

    E-Print Network [OSTI]

    Pham, Hubert

    2013-01-01

    On the desktop, users are accustomed to having visible handles to objects that they can organize, share, and manipulate. Web applications today feature many loosely defined classes of such objects, like flight itineraries, ...

  12. United States Environmental Protection Agency | Office of Air and Radiation (6608J) | EPA 402-F-05-028 | October 2005 www.epa.gov/radiation/yucca

    E-Print Network [OSTI]

    for the disposal of spent nuclear fuel and high-level radioactive waste. The Yucca Mountain facility will only the transportation of waste currently stored at 126 locations across the United States to the facility and enforce of a nuclear waste facility. Passed legislation instructing the EPA to establish standards for a Yucca Mountain

  13. How emissions, climate, and land use change will impact mid-century air quality over the United States: a focus on effects at national parks

    E-Print Network [OSTI]

    Val Martin, M.

    We use a global coupled chemistry–climate–land model (CESM) to assess the integrated effect of climate, emissions and land use changes on annual surface O[subscript 3] and PM[subscript 2.5] in the United States with a focus ...

  14. Gamma Radiation Dose Rate in Air due to Terrestrial Radionuclides in Southern Brazil: Synthesis by Geological Units and Lithotypes Covered by the Serra do Mar Sul Aero-Geophysical Project

    SciTech Connect (OSTI)

    Bastos, Rodrigo O.; Appoloni, Carlos R. [Applied Nuclear Physics Laboratory-Department of Physics-CCE State University of Londrina Campus Universitario-Rodovia Celso Garcia Cid s/n, Cx. Postal 6001, CEP 86051-990, Londrina, PR (Brazil); Pinese, Jose P. P. [Department of Geosciences-CCE State University of Londrina Campus Universitario-Rodovia Celso Garcia Cid s/n, Cx. Postal 6001, CEP 86051-990, Londrina, PR (Brazil)

    2008-08-07

    The absorbed dose rates in air due to terrestrial radionuclides were estimated from aerial gamma spectrometric data for an area of 48,600 km{sup 2} in Southern Brazil. The source data was the Serra do Mar Sul Aero-Geophysical Project back-calibrated in a cooperative work among the Geological Survey of Brazil, the Geological Survey of Canada, and Paterson, Grant and Watson Ltd. The concentrations of eU (ppm), eTh (ppm) and K (%) were converted to dose rates in air (nGy{center_dot}h{sup -1}) by accounting for the contribution of each element's concentration. Regional variation was interpreted according to lithotypes and a synthesis was performed according to the basic geological units present in the area. Higher values of total dose were estimated for felsic igneous and metamorphic rocks, with average values varying up to 119{+-}24 nGy{center_dot}h{sup -1}, obtained by Anitapolis syenite body. Sedimentary, metasedimentary and metamafic rocks presented the lower dose levels, and some beach deposits reached the lowest average total dose, 18.5{+-}8.2 nGy{center_dot}h{sup -1}. Thorium gives the main average contribution in all geological units, the highest value being reached by the nebulitic gneisses of Atuba Complex, 71{+-}23 nGy{center_dot}h{sup -1}. Potassium presents the lowest average contribution to dose rate in 53 of the 72 units analyzed, the highest contribution being obtained by intrusive alkaline bodies (28{+-}12 nGy{center_dot}h{sup -1}). The general pattern of geographic dose distribution respects well the hypotheses on geo-physicochemical behavior of radioactive elements.

  15. Commercial Storage and Handling of Sorghum Grain. 

    E-Print Network [OSTI]

    Brown, Charles W.; Moore, Clarence A.

    1963-01-01

    relative humidity and relatively hot summer and cold winter temperatures. M7inter temperatures below freezing are common. Since harvest occurs from September through November, the temperature of new grain moving into storage is not high. Sorghum grain... a cross section of physical and economic conditions under which sorghum grain is produced, handled and stored were selected for study of storage and handling facilities and practices by commercial grain storage operators. The High Plains...

  16. Oxygen Handling and Cooling Options in High Temperature Electrolysis Plants

    SciTech Connect (OSTI)

    Manohar S. Sohal; J. Stephen Herring

    2008-07-01

    Idaho National Laboratory is working on a project to generate hydrogen by high temperature electrolysis (HTE). In such an HTE system, safety precautions need to be taken to handle high temperature oxygen at ~830°C. This report is aimed at addressing oxygen handling in a HTE plant.. Though oxygen itself is not flammable, most engineering material, including many gases and liquids, will burn in the presence of oxygen under some favorable physicochemical conditions. At present, an absolute set of rules does not exist that can cover all aspects of oxygen system design, material selection, and operating practices to avoid subtle hazards related to oxygen. Because most materials, including metals, will burn in an oxygen-enriched environment, hazards are always present when using oxygen. Most materials will ignite in an oxygen-enriched environment at a temperature lower than that in air, and once ignited, combustion rates are greater in the oxygen-enriched environment. Even many metals, if ignited, burn violently in an oxygen-enriched environment. However, these hazards do not preclude the operations and systems involving oxygen. Oxygen can be safely handled and used if all the materials in a system are not flammable in the end-use environment or if ignition sources are identified and controlled. In fact, the incidence of oxygen system fires is reported to be low with a probability of about one in a million. This report is a practical guideline and tutorial for the safe operation and handling of gaseous oxygen in high temperature electrolysis system. The intent is to provide safe, practical guidance that permits the accomplishment of experimental operations at INL, while being restrictive enough to prevent personnel endangerment and to provide reasonable facility protection. Adequate guidelines are provided to govern various aspects of oxygen handling associated with high temperature electrolysis system to generate hydrogen. The intent here is to present acceptable oxygen standards and practices for minimum safety requirements. A summary of operational hazards, along with oxygen safety and emergency procedures, are provided.

  17. B S P Course Course Name Cross Listed P 140 Energy and Environment (F, 4 units)

    E-Print Network [OSTI]

    Wildermuth, Mary C

    (alternate spring semesters, 3 units) P 103 Introduction to Hydrology (SP, 3 units) B P C106 Air Pollution (F, 3 units) EPS C180, ESPM C180 B S P 107 Climate Change Mitigation (SP, 3 units) P 108 Air Pollutant Air Pollution (F, 3 units) ESPM C180 P C181 Atmospheric Physics and Dynamics (3 units) GEOG C139 P C

  18. Studentnumber:Name:Degree: Unit:Unit:Unit:Unit

    E-Print Network [OSTI]

    Tobar, Michael

    Studentnumber:Name:Degree: Semester: Semester: Unit:Unit:Unit:Unit: Unit:Unit:Unit:Unit: Year the Undergraduate Degree Course Rules. Have you included units that will lead to at least one degree-specific major that the units you choose in first year will lead to at least one degree-specific major. It is a requirement

  19. Early Markets: Fuel Cells for Material Handling Equipment | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Early Markets: Fuel Cells for Material Handling Equipment Early Markets: Fuel Cells for Material Handling Equipment This fact sheet describes the use of hydrogen fuel cells to...

  20. Contact-Handled Transuranic Waste Authorized Methods for Payload...

    Office of Environmental Management (EM)

    Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH TRAMPAC) Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH TRAMPAC) This...

  1. RESCHEDULED: Webinar on Material Handling Fuel Cells for Building...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    RESCHEDULED: Webinar on Material Handling Fuel Cells for Building Electric Peak Shaving Applications RESCHEDULED: Webinar on Material Handling Fuel Cells for Building Electric Peak...

  2. LM Records Handling System-Fernald Historical Records System...

    Office of Environmental Management (EM)

    Fernald Historical Records System, Office of Legacy Management LM Records Handling System-Fernald Historical Records System, Office of Legacy Management LM Records Handling...

  3. Building Efficiency and Indoor Air Quality - You Can Have Both 

    E-Print Network [OSTI]

    Kettler, G. J.

    1998-01-01

    , and run around loops. These methods can be used on some packaged equipment but is normally provided on makeup air units and central air supply systems. These built up units offer opportunities to combine heat recovery, special filtration, humidity control...

  4. Study of an integrated appliance, the air conditioner/heat pump-heat recovery unit-water heater. Final report, November 1980

    SciTech Connect (OSTI)

    Tu, K.M.; Davies, A.; Fischler, S.

    1981-02-01

    Three integrated heat-pump - heat-recovery-unit - water-heater appliances were tested under various environmental conditions to measure the functional parameters and study the operating characteristics of these systems. It was found that the heat recovery, heat-recovery rate, and heat-recovery efficiency were dependent on the heat-recovery-unit's characteristics. The use of the heat-recovery unit in the system resulted in a reduced work load for the heat pump's compressor and slightly improved the heat-pump's performance. A computer simulation model of the integrated system was developed to study the interactions between several of the pertinent system variables on an hourly basis for selected situations and to estimate energy savings. Two alternative estimation methods that utilize five-degree temperature bin data were also developed. The estimate savings determined by using the alternative methods were about the same as those estimated using the hourly data. Conclusions were also reached concerning the use of water heaters with different tank capacities and on methods of increasing potential energy savings.

  5. Electrically Heated High Temperature Incineration of Air Toxics 

    E-Print Network [OSTI]

    Agardy, F. J.; Wilcox, J. B.

    1990-01-01

    In-Process Technology has placed a prototype of its patented, electrically heated, packed-bed air toxics oxidizer at a northern California chemical plant. This thermal oxidizer is capable of handling a wide range of chlorinated and non...

  6. Criminal provisions of the Clean Air Act Amendments of 1990 and their interface with the United States sentencing guidelines. Master's thesis

    SciTech Connect (OSTI)

    Bowen, W.P.

    1991-09-30

    The growing severity of our societal response to environmental misconduct is reflected, in part, by the criminalization of environmental wrongs by both state and Federal governments. Indeed, the recently enacted Clean Air Act Amendments of 1990 continue this trend, giving the Environmental Protection Agency, via the Department of Justice, significant new criminal enforcement tools. The importance attached to law enforcement of environmental laws is a relatively recent phenomenon and took a significant upswing in 1982 when the department of Justice created what is today the Environmental Crimes Section in what is now the Environment and Natural Resources Division, which section has grown steadily and now has over 25 attorneys who prosecute or assist in the prosecution of environmental crimes in the U.S.

  7. DOE handbook: Tritium handling and safe storage

    SciTech Connect (OSTI)

    1999-03-01

    The DOE Handbook was developed as an educational supplement and reference for operations and maintenance personnel. Most of the tritium publications are written from a radiological protection perspective. This handbook provides more extensive guidance and advice on the null range of tritium operations. This handbook can be used by personnel involved in the full range of tritium handling from receipt to ultimate disposal. Compliance issues are addressed at each stage of handling. This handbook can also be used as a reference for those individuals involved in real time determination of bounding doses resulting from inadvertent tritium releases. This handbook provides useful information for establishing processes and procedures for the receipt, storage, assay, handling, packaging, and shipping of tritium and tritiated wastes. It includes discussions and advice on compliance-based issues and adds insight to those areas that currently possess unclear DOE guidance.

  8. Automated system for handling tritiated mixed waste

    SciTech Connect (OSTI)

    Dennison, D.K.; Merrill, R.D.; Reitz, T.C.

    1995-03-01

    Lawrence Livermore National Laboratory (LLNL) is developing a semi system for handling, characterizing, processing, sorting, and repackaging hazardous wastes containing tritium. The system combines an IBM-developed gantry robot with a special glove box enclosure designed to protect operators and minimize the potential release of tritium to the atmosphere. All hazardous waste handling and processing will be performed remotely, using the robot in a teleoperational mode for one-of-a-kind functions and in an autonomous mode for repetitive operations. Initially, this system will be used in conjunction with a portable gas system designed to capture any gaseous-phase tritium released into the glove box. This paper presents the objectives of this development program, provides background related to LLNL`s robotics and waste handling program, describes the major system components, outlines system operation, and discusses current status and plans.

  9. Eastman, AP start on coal unit

    SciTech Connect (OSTI)

    1995-10-25

    Eastman Chemical and Air Products and Chemicals (AP) have started construction of a $214-million, coal-to-methanol demonstration unit at Eastmans site in Kingsport, TN. The project is part of the Department of Energy`s clean coal technology program and is receiving $93 million in federal support. The demonstration unit-which will have a methanol capacity of 260 tons/day-will use novel catalyst technology for converting coal-derived synthesis gas (syngas) to methanol. Unlike conventional technology that processes syngas through a fixed bed of dry catalyst particles, the liquid-phase methanol process converts the syngas in a single vessel containing catalysts suspended in mineral oil. The companies say the innovation allows the process to better able handle the gases from coal gasifiers and is more stable and reliable than existing processes. Eastman says it will use the methanol produced by the plant as a chemical feedstock. It currently uses methanol as an intermediate in making acetic anhydride and dimethyl terephthalate. In addition, the companies say the methanol will be evaluated as a feedstock in making methyl tert-butyl ether for reformulated fuels. Eastman also says it will evaluate coproducing dimethyl ether (DME) with the methanol. DME can be used as a fuel additive or blended with methanol for a chemical feedstock, according to Eastman.

  10. Zach Harmon Air Chemistry

    E-Print Network [OSTI]

    Toohey, Darin W.

    in the Troposphere Summary of Problem/Impact United States dependency on foreign oil and increased energy consumptionZach Harmon 810907207 Air Chemistry Natural Gas Production Impacts on levels of ozone administration to encourage fast growth to reduce dependency of foreign oil and be energy independent. It

  11. Handling Change Management using Temporal Active Repositories

    E-Print Network [OSTI]

    Gal, Avigdor

    Handling Change Management using Temporal Active Repositories Avigdor Gal and Opher Etzion and their management. In this paper we introduce an architecture of change man- agement using active temporal repositories. Flexible change management allows the support of information about past or future versions

  12. GUIDELINES FOR HANDLING HAZARDOUS CHEMICAL WASTE

    E-Print Network [OSTI]

    Tennessee, University of

    GUIDELINES FOR HANDLING HAZARDOUS CHEMICAL WASTE The proper management of hazardous waste and regulatory compliance are achieved: 1. Make sure that no hazardous materials are placed into regular solid in the departmental chemical hygiene plan (CHP) before you begin to use hazardous substances. 3. Make sure you know

  13. INTELLIGENT HANDLING OF WEATHER FORECASTS Stephan Kerpedjiev

    E-Print Network [OSTI]

    , discourse and semantic. They are based on a conceptual model underlying weather forecasts as well situations represented in the form of texts in NL, weather maps, data tables or combined information objectsINTELLIGENT HANDLING OF WEATHER FORECASTS Stephan Kerpedjiev I n s t i t u t e of Mathematics Acad

  14. Remote handling facility and equipment used for space truss assembly

    SciTech Connect (OSTI)

    Burgess, T.W.

    1987-01-01

    The ACCESS truss remote handling experiments were performed at Oak Ridge National Laboratory's (ORNL's) Remote Operation and Maintenance Demonstration (ROMD) facility. The ROMD facility has been developed by the US Department of Energy's (DOE's) Consolidated Fuel Reprocessing Program to develop and demonstrate remote maintenance techniques for advanced nuclear fuel reprocessing equipment and other programs of national interest. The facility is a large-volume, high-bay area that encloses a complete, technologically advanced remote maintenance system that first began operation in FY 1982. The maintenance system consists of a full complement of teleoperated manipulators, manipulator transport systems, and overhead hoists that provide the capability of performing a large variety of remote handling tasks. This system has been used to demonstrate remote manipulation techniques for the DOE, the Power Reactor and Nuclear Fuel Development Corporation (PNC) of Japan, and the US Navy in addition to the National Aeronautics and Space Administration. ACCESS truss remote assembly was performed in the ROMD facility using the Central Research Laboratory's (CRL) model M-2 servomanipulator. The model M-2 is a dual-arm, bilateral force-reflecting, master/slave servomanipulator which was jointly developed by CRL and ORNL and represents the state of the art in teleoperated manipulators commercially available in the United States today. The model M-2 servomanipulator incorporates a distributed, microprocessor-based digital control system and was the first successful implementation of an entirely digitally controlled servomanipulator. The system has been in operation since FY 1983. 3 refs., 2 figs.

  15. Methods for the Safe Storage, Handling, and Disposal of Pyrophoric Liquids and Solids in the Laboratory

    SciTech Connect (OSTI)

    Alnajjar, Mikhail S.; Quigley, David; Kuntamukkula, Murty; Simmons, Fred; Freshwater, David; Bigger, Samuel

    2011-01-01

    Due to the inherent nature of pyrophoric substances to ignite spontaneously upon exposure to air, special precautions must be taken to ensure their safe handling and use. Pyrophoric gases (such as diborane, dichloroborane, phosphine, etc.) are typically the easiest class of pyrophoric substances to handle since the gas can be plumbed directly to the application and used remotely. Pyrophoric solids and liquids, however, require the user to physically manipulate them when transferring them from one container to another. Failure to follow proper safety precautions could result in serious injury or unintended consequences to laboratory personnel.12 Because of this danger, pyrophorics should be handled only by experienced personnel. Users with limited experience must be trained on how to handle pyrophoric reagents and consult with a knowledgeable staff member prior to performing the experimental task. The purpose of this article is three fold: 1) to provide guidelines and general safety precautions to avoid accidents, 2) describe proper techniques on how to successfully handle, store, and dispose of pyrophoric liquids and solids, and 3) illustrate best practices for working with this class of reactants in a laboratory environment.

  16. Meteorological database for the United States

    E-Print Network [OSTI]

    Apte, M.G.

    2011-01-01

    to Indoor Air Meteorological Database for the United StatesUC-402 Meteorological Database for the United States M.G.Abstract A meteorological database has been developed to aid

  17. Powder handling for automated fuel processing

    SciTech Connect (OSTI)

    Frederickson, J.R.; Eschenbaum, R.C.; Goldmann, L.H.

    1989-04-09

    Installation of the Secure Automated Fabrication (SAF) line has been completed. It is located in the Fuel Cycle Plant (FCP) at the Department of Energy's (DOE) Hanford site near Richland, Washington. The SAF line was designed to fabricate advanced reactor fuel pellets and assemble fuel pins by automated, remote operation. This paper describes powder handling equipment and techniques utilized for automated powder processing and powder conditioning systems in this line. 9 figs.

  18. Improving Memory Error Handling Using Linux

    SciTech Connect (OSTI)

    Carlton, Michael Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Blanchard, Sean P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Debardeleben, Nathan A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-07-25

    As supercomputers continue to get faster and more powerful in the future, they will also have more nodes. If nothing is done, then the amount of memory in supercomputer clusters will soon grow large enough that memory failures will be unmanageable to deal with by manually replacing memory DIMMs. "Improving Memory Error Handling Using Linux" is a process oriented method to solve this problem by using the Linux kernel to disable (offline) faulty memory pages containing bad addresses, preventing them from being used again by a process. The process of offlining memory pages simplifies error handling and results in reducing both hardware and manpower costs required to run Los Alamos National Laboratory (LANL) clusters. This process will be necessary for the future of supercomputing to allow the development of exascale computers. It will not be feasible without memory error handling to manually replace the number of DIMMs that will fail daily on a machine consisting of 32-128 petabytes of memory. Testing reveals the process of offlining memory pages works and is relatively simple to use. As more and more testing is conducted, the entire process will be automated within the high-performance computing (HPC) monitoring software, Zenoss, at LANL.

  19. Human error contribution to nuclear materials-handling events

    E-Print Network [OSTI]

    Sutton, Bradley (Bradley Jordan)

    2007-01-01

    This thesis analyzes a sample of 15 fuel-handling events from the past ten years at commercial nuclear reactors with significant human error contributions in order to detail the contribution of human error to fuel-handling ...

  20. Strategy Guideline: Compact Air Distribution Systems

    SciTech Connect (OSTI)

    Burdick, A.

    2013-06-01

    This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  1. Canmet hydrocracking handles wide range of heavy crudes

    SciTech Connect (OSTI)

    Waugh, R.J.; Chambers, L.W.; Menzies, M.A.; Patmore, D.J.

    1983-03-01

    The track record of successful or realistic projections within industry over recent years has not exactly been outstanding. It almost seems that as the tools and methods that are available become more sophisticated, the less effective they are because of our inability to predict major events and their adverse impact on otherwise realistic projections. Crude oil sources, gravity and prices coupled with product type, demand and quality have all been affected. One thing that one can say with reasonable certainty is that there is no apparent reason to assume that the scene will stabilize in the near or mid-term future. Thus, the refiner is faced with continuing uncertainty as to crude source and product demand. He, therefore, has need to maintain flexibility in being able to process as wide a range of crudes and to produce as wide a range of products as possible. This paper postulates that the CANMET Hydrocracking Process can assist in achieving a greater degree of flexibility in refinery operation through its ability to handle a wide range of heavy feedstocks. The authors report new yield data for heavy feeds and the status of the previously announced demonstration unit. The unit is being designed on the basis of extensive data developed at the CANMET and Petro Canada laboratories in Ottawa and Calgary, Alberta, respectively. The paper concludes with a suggested modular application of CANMET hydrocracking to Athabasca Tar Sands development.

  2. Table HC15.7 Air-Conditioning Usage Indicators by Four Most...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    or More Units... 5.4 0.7 Q 0.5 Q Central Air-Conditioning Usage Air-Conditioned Floorspace (Square Feet)...

  3. Data Freshness and Overload Handling in Embedded Systems Thomas Gustafssona

    E-Print Network [OSTI]

    Data Freshness and Overload Handling in Embedded Systems Thomas Gustafssona and J¨orgen Hanssonb@sei.cmu.edu Abstract In this paper we consider data freshness and overload handling in embedded systems. The requirements on data management and overload handling are derived from an engine control software. Data items

  4. Air-to-air turbocharged air cooling versus air-to-water turbocharged air cooling

    SciTech Connect (OSTI)

    Moranne, J.-P.; Lukas, J.J.

    1984-01-01

    In Europe, turbocharged air in diesel engines used in on-road vehicles is cooled only by air. It is expected that by 1990, ten to twelve percent of European heavy trucks with diesel engines will cool turbocharged air by water. Air-to-air turbocharges air cooling is reviewed and the evolution of air-to-water turbocharged air cooling presented before the two systems are compared.

  5. Compatible and Cost-Effective Fault Diagnostic Solutions for...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Compatible and Cost-Effective Fault Diagnostic Solutions for Air Handling Unit-Variable Air Volume and Air Handling Unit-Constant Air Volume Systems - 2014 BTO Peer Review...

  6. Effectiveness of the Clean Air Act on SO? emissions from U.S. electric utilities : a detailed analysis of the influence of attainment status and unit-level characteristics on the reduction of SO? emissions from 1976 to 2002

    E-Print Network [OSTI]

    Dubroeucq, Florence

    2004-01-01

    The continuing degradation of air quality in the U.S. during the 1950s and 1960s has led to increasing federal regulations to control air pollution. The Clean Air Act Amendments of 1970 and 1977 were major pieces of ...

  7. System for handling and storing radioactive waste

    DOE Patents [OSTI]

    Anderson, J.K.; Lindemann, P.E.

    1982-07-19

    A system and method are claimed for handling and storing spent reactor fuel and other solid radioactive waste, including canisters to contain the elements of solid waste, storage racks to hold a plurality of such canisters, storage bays to store these racks in isolation by means of shielded doors in the bays. This system also includes means for remotely positioning the racks in the bays and an access tunnel within which the remotely operated means is located to position a rack in a selected bay. The modular type of these bays will facilitate the construction of additional bays and access tunnel extension.

  8. System for handling and storing radioactive waste

    DOE Patents [OSTI]

    Anderson, John K. (San Diego, CA); Lindemann, Paul E. (Escondido, CA)

    1984-01-01

    A system and method for handling and storing spent reactor fuel and other solid radioactive waste, including canisters to contain the elements of solid waste, storage racks to hold a plurality of such canisters, storage bays to store these racks in isolation by means of shielded doors in the bays. This system also includes means for remotely positioning the racks in the bays and an access tunnel within which the remotely operated means is located to position a rack in a selected bay. The modular type of these bays will facilitate the construction of additional bays and access tunnel extension.

  9. Handling Food and Supplies during Power Loss 

    E-Print Network [OSTI]

    Anding, Jenna

    2005-09-30

    or uncertain, reduce your risk of getting sick by buying food that doesn?t require refrigeration or prepara- tion. Suggested Food Handling Food and Supplies during Power Loss ? Ready-to-eat canned/pouched meats/meals (e.g., tuna, chicken, spaghetti... or gas commonly occurs during storms or other natural disasters. However, power loss may continue for weeks after the storm has passed, especially if an area has been damaged by floods or high winds. If you are in an area where power is limited...

  10. United Cool Air | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyThe U.S.Laclede GasEfficiency|Feed|Department ofInspector General -ofproviding theour

  11. Typical Problems of AHU and Air Movement in Buildings 

    E-Print Network [OSTI]

    2006-01-01

    of AHU and Air Typical Problems of AHU and Air Movement in Buildings Movement in Buildings TsinghuaTsinghua UniversityUniversityOct. 2006Oct. 2006 22 ???????? Supply More Than NeededSupply More Than Needed ???????? TP1: Oversize of fresh air supplyTP1...: Oversize of fresh air supply ???????? TP2: CAV serving big spaceTP2: CAV serving big space ???????? TP3: Continuously running in partial time occupied zonesTP3: Continuously running in partial time occupied zones ???????? Wrong Air Handling Process...

  12. The Clean Air Interstate Rule

    SciTech Connect (OSTI)

    Debra Jezouit; Frank Rambo

    2005-07-01

    On May 12, 2005, EPA promulgated the Clean Air Interstate Rule, which overhauls and expands the scope of air emissions trading programs in the eastern United States. The rule imposes statewide caps on emissions of nitrogen oxides and sulfur dioxide to be introduced in two phases, beginning in 2009. This article briefly explains the background leading up to the rule and summarizes its key findings and requirements. 2 refs., 1 fig., 1 tab.

  13. Automated control for coal handling operations at Bethlehem Steel, Burns Harbor Division

    SciTech Connect (OSTI)

    Zendzian, T.N. [Bethlehem Steel Corp., Chesterton, IN (United States). Burns Harbor Div.

    1997-12-31

    The Burns Harbor coal handling operation processes 7,200 tons of coal per day to supply two 82 oven, six meter batteries. The operations in coal handling are subdivided into three separate sections: the coal field and stacker reclaimer operation, the crushing and storage of coal, and the coal blending operation. In 1996 a supervisory system was developed and installed to fully automate all the operations and equipment in the coal handling unit, add additional instrumentation and logic controls to prevent coal contamination, and improve data collection and logging. The supervisory system is operated from a computer based workstation and is based on a distributed control philosophy utilizing programmable logic controllers, set point controllers, and man-machine interface displays. The previous control system for the coal handling operation consisted of a switchboard from which an operator controller the set up and running of the conveyor systems and equipment to stack, reclaim, and blend coal. The new supervisory system was installed in parallel with the original control system to safeguard continued operation during the system installation and commissioning. The original system still exists and can be operated in even of failure of the supervisory system.

  14. ASME PTC 47 - IGCC performance testing: Air separation issues

    SciTech Connect (OSTI)

    Smith, A.R.

    1998-07-01

    Air separation units have been incorporated into the designs of many gasification combined cycle projects worldwide for the supply of pressurized oxygen and nitrogen. Pressurized gaseous oxygen at a purity usually above 95% by volume is supplied to the gasification unit to partially oxidized a hydrocarbon feed to yield syngas. Nitrogen streams are used for purging and inerting purposes or for the reactor. Several facilities have incorporated integration of air and/or nitrogen streams between the gas turbine and the air separation unit to improve overall facility cost, power output and efficiency. Gasification processes that are based on air as the oxidant source may also require an air separation unit to supply pressurized nitrogen for inerting and dry fuel transport. This paper reports on the progress of PTC 47's air separation subcommittee in defining test measurement boundaries and performance parameter definitions for the testing of an air separation unit as a subsystem of the gasification combined cycle facility.

  15. CWS-Fired Residential Warm-Air Heating System

    SciTech Connect (OSTI)

    Balsavich, J.; Becker, F.E.; Smolensky, L.A.

    1989-07-01

    During the report period, work continued on the life-cycle testing, optimization and refining of the second-generation furnace assembly, which comprises all the major furnace components: The combustor, heat exchanger, and baghouse, as well as the auxiliary subsystems. The furnace has operated for about 90 hours, and has burned 1,000 pounds of CWS. During testing, the only maintenance that was performed on the system was to clean the bag filters to obtain ash samples for analysts. Concurrent with testing the second-generation furnace, fabrication and assembly of the third-generation furnace was completed, and a life-cycle testing and optimization process for this furnace has started. In contrast to the second-generation furnace, which was designed more as an experimental unit, the third-generation furnace is a stand-alone heating unit Incorporating the standard air handling system, blower, pump, and control box as part of the furnace. During the report period, the third-generation furnace operated for a total of 35 hours, and burned more than 300 pounds of CWS, with average tests lasting 6 hours. During the next quarter, life-cycle testing of the third-generation furnace will continue to identify areas needing further development.

  16. REAL-TIME OPTIMIZATION FOR AIR LIQUIDE GAS PIPELINES NETWORK

    E-Print Network [OSTI]

    Grossmann, Ignacio E.

    REAL-TIME OPTIMIZATION FOR AIR LIQUIDE GAS PIPELINES NETWORK Yash Puranik and Nick Sahinidis (CMU pipelines connecting air separation units and consumers Consumer Consumer O2 network N2 network #12

  17. Fuel handling system for a nuclear reactor

    DOE Patents [OSTI]

    Saiveau, James G. (Hickory Hills, IL); Kann, William J. (Park Ridge, IL); Burelbach, James P. (Glen Ellyn, IL)

    1986-01-01

    A pool type nuclear fission reactor has a core, with a plurality of core elements and a redan which confines coolant as a hot pool at a first end of the core separated from a cold pool at a second end of the core by the redan. A fuel handling system for use with such reactors comprises a core element storage basket located outside of the redan in the cold pool. An access passage is formed in the redan with a gate for opening and closing the passage to maintain the temperature differential between the hot pool and the cold pool. A mechanism is provided for opening and closing the gate. A lifting arm is also provided for manipulating the fuel core elements through the access passage between the storage basket and the core when the redan gate is open.

  18. Safety Enhancements for TRU Waste Handling - 12258

    SciTech Connect (OSTI)

    Cannon, Curt N. [Perma-Fix Northwest Richland, Inc., Richland, WA 99354 (United States)

    2012-07-01

    For years, proper Health Physics practices and 'As Low As Reasonably Achievable' (ALARA) principles have fostered the use of glove boxes or other methods of handling (without direct contact) high activities of radioactive material. The physical limitations of using glove boxes on certain containers have resulted in high-activity wastes being held in storage awaiting a path forward. Highly contaminated glove boxes and other remote handling equipment no longer in use have also been added to the growing list of items held for storage with no efficient method of preparation for proper disposal without creating exposure risks to personnel. This is especially true for wastes containing alpha-emitting radionuclides such as Plutonium and Americium that pose significant health risks to personnel if these Transuranic (TRU) wastes are not controlled effectively. Like any good safety program or root cause investigation PFNW has found that the identification of the cause of a negative change, if stopped, can result in a near miss and lessons learned. If this is done in the world of safety, it is considered a success story and is to be shared with others to protect the workers. PFNW believes that the tools, equipment and resources have improved over the past number of years but that the use of them has not progressed at the same rate. If we use our tools to timely identify the effect on the work environment and immediately following or possibly even simultaneously identify the cause or some of the causal factors, we may have the ability to continue to work rather than succumb to the start and stop-work mentality trap that is not beneficial in waste minimization, production efficiency or ALARA. (authors)

  19. Overview on Hydrate Coring, Handling and Analysis

    SciTech Connect (OSTI)

    Jon Burger; Deepak Gupta; Patrick Jacobs; John Shillinglaw

    2003-06-30

    Gas hydrates are crystalline, ice-like compounds of gas and water molecules that are formed under certain thermodynamic conditions. Hydrate deposits occur naturally within ocean sediments just below the sea floor at temperatures and pressures existing below about 500 meters water depth. Gas hydrate is also stable in conjunction with the permafrost in the Arctic. Most marine gas hydrate is formed of microbially generated gas. It binds huge amounts of methane into the sediments. Worldwide, gas hydrate is estimated to hold about 1016 kg of organic carbon in the form of methane (Kvenvolden et al., 1993). Gas hydrate is one of the fossil fuel resources that is yet untapped, but may play a major role in meeting the energy challenge of this century. In June 2002, Westport Technology Center was requested by the Department of Energy (DOE) to prepare a ''Best Practices Manual on Gas Hydrate Coring, Handling and Analysis'' under Award No. DE-FC26-02NT41327. The scope of the task was specifically targeted for coring sediments with hydrates in Alaska, the Gulf of Mexico (GOM) and from the present Ocean Drilling Program (ODP) drillship. The specific subjects under this scope were defined in 3 stages as follows: Stage 1: Collect information on coring sediments with hydrates, core handling, core preservation, sample transportation, analysis of the core, and long term preservation. Stage 2: Provide copies of the first draft to a list of experts and stakeholders designated by DOE. Stage 3: Produce a second draft of the manual with benefit of input from external review for delivery. The manual provides an overview of existing information available in the published literature and reports on coring, analysis, preservation and transport of gas hydrates for laboratory analysis as of June 2003. The manual was delivered as draft version 3 to the DOE Project Manager for distribution in July 2003. This Final Report is provided for records purposes.

  20. Laboratory Thin-Film Encapsulation of Air-Sensitive Organic Semiconductor Devices

    E-Print Network [OSTI]

    Subbarao, Samuel P.

    We present an approach, which is compatible with both glass and polymer substrates, to in-laboratory handling and intra-laboratory shipping of air-sensitive organic semiconductors. Encapsulation approaches are presented ...

  1. Analysis of Air Conditioning Effectiveness vs. Outdoor Conditions: Traditional Bins or Joint Frequency Bins? 

    E-Print Network [OSTI]

    Cohen, B. M.

    1998-01-01

    There are a number of methods used to estimate the effectiveness of air conditioning equipment in handling loads. Full hourly computer simulations are probably the most accurate, but lack flexibility and are more cumbersome ...

  2. NUMERICAL SIMULATIONS OF AIR FLOW AND HEAT TRANSFER VIA PDES Fei Cao, Luz Angelica Caudillo-Mata, Natalia Iwanski, Yong Li, Kamran Sadiq,

    E-Print Network [OSTI]

    by the air conditioning units (ACUs) with large scale fans into the plenum thereby pressurizing it of the air conditioning units; these are meant to extract (hot) air out of the room. Thus, equipment like

  3. DOE Requires Air-Con International to Cease Sales of Inefficient...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Penalty to Air-Con, International, requiring Air-Con to cease the sale of certain air-conditioning systems in the United States and proposing a civil penalty of 231,090 for sales...

  4. Air-Con International: Order (2010-SE-0301)

    Broader source: Energy.gov [DOE]

    DOE ordered Air-Con International, Inc. to pay a civil penalty of $10,000 after finding Air-Con had distributed in commerce in the U.S. central air conditioning units that were not in conformity with the applicable energy conservation standards. DOE also found that, while some units were exported, none of the units were properly marked as imports intended for exportation.

  5. Urenco`s experience of UF{sub 6} handling

    SciTech Connect (OSTI)

    Saelmans, F. [Urenco Almelo (Netherlands); Scane, C. [Urenco Capenhurst (United Kingdom); Christofzik, J. [Urenco Gronau (Germany)

    1991-12-31

    Urenco operates enrichment plants at three sites, Almelo (Netherlands), Capenhurst (United Kingdom) and Gronau (Germany). Current installed separative work capacity is 2,500 tSWpa. Since 1971, when the first pilot plants were built, enrichment production has totalled 18,000 tSW. During this last 20 years over 3,500 48 containers of UF{sub 6} have been fed to the plants, over 3,700 30 containers have been filled with product and delivered successfully to Urenco`s customers worldwide and over 3,000 48 containers of depleted tails have been filled and have either been returned to customers or retained for long term storage on site. The paper gives a brief outline of Urenco`s experience in handling UF{sub 6}: the equipment and methods used in receiving, feeding, filling, blending, liquid sampling, storing, moving on site and despatching of UF{sub 6} containers. Some of the difficulties experienced with UF{sub 6} containers are appended.

  6. Air-Side Energy Use Calculations for Four HVAC Systems: Dual Duct Constant Volume (DDCAV), Dual Duct Variable Volume (DDVAV), Constant Volume with Reheat (CAVRH), Variable Volume with Reheat (VAVRH), Four Pipe Fan Coil Unit (FC), Four Pipe Induction Unit (FI), and Single Zone (SZ) Systems, Revised June 2002 

    E-Print Network [OSTI]

    Haberl, J. S.; Bou-Saada, T. E.; Saman, N. F.

    2001-01-01

    This report contains engineering calculations for seven (7) air-side, heating, ventilating and air conditioning systems (HVAC) systems, including: dual duct constant volume (DDCAV), dual duct variable volume (DDVAV), ...

  7. Performance Evaluation of Radiant Cooling System Integrated with Air System under Different Operational Strategies

    SciTech Connect (OSTI)

    Khare, Vaibhav [Malaviya National Institute of Technology (MNIT), Jaipur, India; Khan, Yasin [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    The paper describes a parametric study developed to estimate the energy savings potential of a radiant cooling system installed in a commercial building in India. The study is based on numerical modeling of a radiant cooling system installed in an Information Technology (IT) office building sited in the composite climate of Hyderabad. To evaluate thermal performance and energy consumption, simulations were carried out using the ANSYS FLUENT and EnergyPlus softwares, respectively. The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption of a building using a conventional all-air system to determine the proportional energy savings. For proper handling of the latent load, a dedicated outside air system (DOAS) was used as an alternative to Fan Coil Unit (FCU). A comparison of energy consumption calculated that the radiant system was 17.5 % more efficient than a conventional all-air system and that a 30% savings was achieved by using a DOAS system compared with a conventional system. Computational Fluid Dynamics (CFD) simulation was performed to evaluate indoor air quality and thermal comfort. It was found that a radiant system offers more uniform temperatures, as well as a better mean air temperature range, than a conventional system. To further enhance the energy savings in the radiant system, different operational strategies were analyzed based on thermal analysis using EnergyPlus. The energy savings achieved in this parametric run were more than 10% compared with a conventional all-air system.

  8. BUILDING A UNITED STATES DATA BASE: POPULATIONS AT RISK TO ENVIRONMENTAL POLLUTION

    E-Print Network [OSTI]

    Sacks, Susan T.

    2014-01-01

    BUILDING A UNITED STATES DATA BASE: POPULATIONS AT RISK TOBUILDING A UNITED STATES DATA BASE: POPULATIONS AT RISK TOof an demographic integrated data base characteristics, air

  9. Central Characterization Program (CCP) Contact-Handled (CH) TRU...

    Office of Environmental Management (EM)

    and Waste Information SystemWaste Data System (WWISWDS) Data Entry Central Characterization Program (CCP) Contact-Handled (CH) TRU Waste Certification and Waste Information...

  10. Biodiesel Handling and Use Guide: Fourth Edition (Revised)

    SciTech Connect (OSTI)

    Not Available

    2009-01-01

    Intended for those who blend, distribute, and use biodiesel and its blends, this guide contains procedures for handling and using these fuels.

  11. Handling and Packaging a Potentially Radiologically Contaminated Patient

    Broader source: Energy.gov [DOE]

    The purpose of this procedure is to provide guidance to EMS care providers for properly handling and packaging potentially radiologically contaminated patients.

  12. LM Records Handling System (LMRHS01) - Rocky Flats Environmental...

    Energy Savers [EERE]

    Rocky Flats Environmental Records Database, Office of Legacy Management LM Records Handling System (LMRHS01) - Rocky Flats Environmental Records Database, Office of Legacy...

  13. Handbook for Handling, Storing, and Dispensing E85

    SciTech Connect (OSTI)

    Not Available

    2008-04-01

    Guidebook contains information about EPAct alternative fuels regulations for fleets, flexible fuel vehicles, E85 properties and specifications, and E85 handling and storage guidelines.

  14. LM Records Handling System (LMRHS01) - Energy Employees Occupational...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Employees Occupational Illness Compensation Program Act, Office of Legacy Management LM Records Handling System (LMRHS01) - Energy Employees Occupational Illness...

  15. LM Records Handling System (LMRHS01) - Electronic Records Keeping...

    Office of Environmental Management (EM)

    System (LMRHS01) - Electronic Records Keeping System, Office of Legacy Management, LM Records Handling System (LMRHS01) - Electronic Records Keeping System, Office of Legacy...

  16. Remote-Handled Transuranic Content Codes

    SciTech Connect (OSTI)

    Washington TRU Solutions

    2006-12-01

    The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC).1 The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: • A two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]). The site-specific letter designations for each of the sites are provided in Table 1. • A three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is “3.” The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Table 2 provides a brief description of each generic code. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code. If a site implements the administrative controls outlined in the RH-TRAMPAC and Appendix 2.4 of the RH-TRU Payload Appendices, the decay heat or FGGR limits based on a 10-day shipping period (rather than the standard 60-day shipping period) may be used as specified in an approved content code.

  17. " Million Housing Units, Final...

    U.S. Energy Information Administration (EIA) Indexed Site

    .2,7.1,4.4,2.6,1.3,3,6.8 "Central Warm-Air Furnace",19.1,4.6,5.5,3.6,2.2,1.2,0.6,1.4,3.5 "Heat Pump",9.8,1.4,2,2,1.4,1,0.6,1.3,0.9 "Built-In Electric Units",5.7,1.9,1.6,0.9,0.6,0.3...

  18. Innovative Evaporative and Thermally Activated Technologies Improve Air Conditioning; The Spectrum of Clean Energy Innovation (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2010-06-01

    Fact sheet describes NREL's work on a desiccant enhanced evaporative air conditioner (DEVap) that uses 90% less electricity than traditional air conditioning units.

  19. Measured Impacts of Air Conditioner Condenser Shading 

    E-Print Network [OSTI]

    Parker, D. S.; Barkaszi, S. F.; Sonne, J. K.

    1996-01-01

    A study has been conducted by the Florida Solar Energy Center (FSEC) to examine if space cooling energy savings can be achieved from shading of residential air conditioning (AC) condenser units. The investigation consisted of before...

  20. UNITED STATES NUCLEAR WASTE TECHNICAL REVIEW BOARD

    E-Print Network [OSTI]

    of Energy's (DOE) activities related to disposing of, packaging, and transporting high-level radioactive-complex sites; handling, transporting, processing, and storing the waste; and emplacing the waste undergroundUNITED STATES NUCLEAR WASTE TECHNICAL REVIEW BOARD 2300 Clarendon Boulevard, Suite 1300 Arlington

  1. SOFTWARE AGENTS IN HANDLING ABNORMAL SITUATIONS IN INDUSTRIAL PLANTS

    E-Print Network [OSTI]

    SOFTWARE AGENTS IN HANDLING ABNORMAL SITUATIONS IN INDUSTRIAL PLANTS Sami Syrjälä and Seppo Kuikka Institute of Automation and Control Department of Automation Tampere University of Technology. The abnormal situation handling in industrial plants is a challenging application area due to the complexity

  2. On Managing Temporal Information for Handling Durative Actions in LPG

    E-Print Network [OSTI]

    Gerevini, Alfonso E.

    On Managing Temporal Information for Handling Durative Actions in LPG Alfonso Gerevini, Alessandro Branze 38, 25123 Brescia, Italy fgerevini,saetti,serinag@ing.unibs.it Abstract. LPG is a recent planner good performance. This paper focuses on how LPG represents and manages temporal information to handle

  3. Handling Whiting Aboard Fishing Vessels JOSEPH J. L1CCIARDELLO

    E-Print Network [OSTI]

    Handling Whiting Aboard Fishing Vessels JOSEPH J. L1CCIARDELLO Introduction The same fundamental principles for handling fresh fish in general aboard fishing vessels apply to whiting. There- fore, this article will review the factors which influence the quality of fish aboard fishing boats and will offer re

  4. Optimizing Exception Handling in Workows using Activity Restructuring

    E-Print Network [OSTI]

    Gal, Avigdor

    range from halting a process, through attempts of activity reactivation, to an identi...cs of an exception, exception handling may range from halting a process, through attempts of activity reactivationOptimizing Exception Handling in Workows using Activity Restructuring Mati Golani1 , Avigdor Gal2 1

  5. Waxy crude oil handling in Nigeria; Practices, problems, and prospects

    SciTech Connect (OSTI)

    Ajienka, J.A.; Ikoku, C.U. (Dept. of Petroleum Engineering, Univ. of Port Harcourt, Choba, Port Harcourt (NG))

    1990-01-01

    With case studies, the practices, problems, and prospects of handling waxy crude oils in Nigeria are discussed. Using a rotational viscometer, the temperature dependence of rheological properties and thixotropy of these crudes were determined. Suggestions are given on how to improve handling practices. These suggestions include adequate screening and ranking of wax inhibitors, taking into account pour-point depression, viscosity, and yield value.

  6. Handling Complexity in GIS Interface Design GILBERTO CMARA

    E-Print Network [OSTI]

    Camara, Gilberto

    Handling Complexity in GIS Interface Design GILBERTO CÂMARA RICARDO CARTAXO MODESTO DE SOUZA a proposal for an interface for a GIS, which is aimed at handling the complexity of the different data models information systems, GIS interface design. 1 Introduction One of the most important concerns in GIS design

  7. Apparatus and method for handling magnetic particles in a fluid

    DOE Patents [OSTI]

    Holman, David A. (Richland, WA); Grate, Jay W. (West Richland, WA); Bruckner-Lea, Cynthia J. (Richland, WA)

    2000-01-01

    The present invention is an apparatus and method for handling magnetic particles suspended in a fluid, relying upon the known features of a magnetic flux conductor that is permeable thereby permitting the magnetic particles and fluid to flow therethrough; and a controllable magnetic field for the handling. The present invention is an improvement wherein the magnetic flux conductor is a monolithic porous foam.

  8. Dairy Manure Handling Systems and Equipment. 

    E-Print Network [OSTI]

    Sweeten, John M.

    1983-01-01

    Equipment Type System Tank Wagon, Surface spread' Tank Wagon , Surface spread' Tank Wagon, Soil injection' Irrigation , Stationary gun Irrigation , Traveling gun Irrigation, Traveling gun Nominal capacity 1,500 gal. 3,000 gal. 3,000 gal... wagon and 2000 It. haul distance labor. The total cost of pump, irrigation pipe, and traveling gun sprinkler is similar to the cost of a tank wagon system excluding the power unit (tractor) . Direct slurry irrigation systems can serve the dual...

  9. Air Quality

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room News Publications Traditional KnowledgeAgenda Agenda NERSC UserAgustin Mihi andAir Leaks inAir

  10. Control and Diagnostics for Rooftop Units - 2014 BTO Peer Review...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    This project aims to develop and validate cost-effective methods for rooftop air conditioning unit (RTU) coordination and diagnostics in small commercial buildings. To this...

  11. State and local compliance with Title I of the Clean Air Act. Hearing before the Subcommittee on Clean Air and Nuclear Regulation of the Committee on Environment and Public Works, United States Senate, One Hundred Third Congress, First Session, August 3, 1993

    SciTech Connect (OSTI)

    NONE

    1993-12-31

    The hearing addresses State and local compliance with Title I of The Clean Air Act. Implementation of the Act at local levels are examined, along with difficulties in meeting the clean air attainment goals. Statements of government, academic and industry officials are included along with documents submitted for the record.

  12. Handling effluent from nuclear thermal propulsion system ground tests

    SciTech Connect (OSTI)

    Shipers, L.R.; Allen, G.C.

    1992-09-09

    A variety of approaches for handling effluent from nuclear thermal propulsion system ground tests in an environmentally acceptable manner are discussed. The functional requirements of effluent treatment are defined and concept options are presented within the framework of these requirements. System concepts differ primarily in the choice of fission-product retention and waste handling concepts. The concept options considered range from closed cycle (venting the exhaust to a closed volume or recirculating the hydrogen in a closed loop) to open cycle (real time processing and venting of the effluent). This paper reviews the different methods to handle effluent from nuclear thermal propulsion system ground tests.

  13. NIOSH testimony on indoor air quality: Selected references before the Subcommittee on Superfund, Ocean and Water Protection, Committee on Environment and Public Works, United States Senate by J. Donald Millar, May 26, 1989

    SciTech Connect (OSTI)

    Not Available

    1989-09-01

    The National Institute for Occupational Safety and Health (NIOSH) has compiled the document in response to an increasing number of requests for information about indoor air quality (IAQ), including sick building syndrome. Included in the publication are: NIOSH Congressional testimony that describes the NIOSH IAQ investigations program and summarizes the results of NIOSH research and findings on IAQ problems, NIOSH guidance for conducting indoor air quality investigations, NIOSH journal article on evaluating building ventilation systems, and list of non-NIOSH publications on indoor air quality. As the Federal agency responsible for conducting research and making recommendations for occupational safety and health standards, NIOSH limits its IAQ activities to the occupational environment. The U.S. Environmental Protection Agency (EPA) also conducts an IAQ program and can be contacted for information regarding both occupational and non-occupational settings.

  14. Indoor unit for electric heat pump

    DOE Patents [OSTI]

    Draper, R.; Lackey, R.S.; Fagan, T.J. Jr.; Veyo, S.E.; Humphrey, J.R.

    1984-05-22

    An indoor unit for an electric heat pump is provided in modular form including a refrigeration module, an air mover module, and a resistance heat package module, the refrigeration module including all of the indoor refrigerant circuit components including the compressor in a space adjacent the heat exchanger, the modules being adapted to be connected to air flow communication in several different ways as shown to accommodate placement of the unit in various orientations. 9 figs.

  15. Hybrid Control Models of Next Generation Air Traffic Management ?

    E-Print Network [OSTI]

    Pappas, George J.

    Hybrid Control Models of Next Generation Air Traffic Management ? C. Tomlin, G. Pappas, J. Lygeros the overcrowding of large urban airports and the need to more efficiently handle larger numbers of aircraft malfunctions, ATC malfunctions (e.g. power failure), shifting winds (that cause changes in approach patterns

  16. Determining the Right Air Quality for Your Compressed Air System...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Applications Plant Air Air tools, general plant air Instrument Air Laboratories, paint spraying, powder coating, climate control Process Air Food and pharmaceutical process...

  17. Assessment of China's virtual air pollution transport embodied in trade by using a consumption-based emission inventory

    E-Print Network [OSTI]

    2015-01-01

    helps mitigate global air pollution, P. Natl. Acad. Sci.international trade and air pollution in the United States,of China’s virtual air pollution transport embodied in trade

  18. Promising Technology: High-Efficiency Rooftop Units

    Broader source: Energy.gov [DOE]

    High-efficiency rooftop air conditioning units (RTUs) can significantly reduce heating, cooling, and ventilation energy consumption. High efficiency RTUs incorporate variable speed controls to minimize fan and compressor energy while capturing and reusing heat, cold, and humidity from a building’s exhaust air.

  19. Printed on Recycled Paper United States

    E-Print Network [OSTI]

    the Clean Air Act, further tightening emission standards. The NOx standard is set at 0.6 gpm for cars1 Emission Facts Printed on Recycled Paper United States Environmental Protection Agency Air and Radiation EPA420-F-99-017 May 1999 Office of Mobile Sources The History of Reducing Tailpipe Emissions 1970

  20. T-625: Opera Frameset Handling Memory Corruption Vulnerability

    Broader source: Energy.gov [DOE]

    The vulnerability is caused due to an error when handling certain frameset constructs during page unloading and can be exploited to corrupt memory via a specially crafted web page.

  1. HANDLING UNCERTAINTY IN PRODUCTION ACTIVITY CONTROL USING PROACTIVE SIMULATION

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    HANDLING UNCERTAINTY IN PRODUCTION ACTIVITY CONTROL USING PROACTIVE SIMULATION Olivier CARDIN, Production Control, Manufacturing Systems, Proactive, Real-time. 1. INTRODUCTION In today's complex of a product. Real-word planning and scheduling problems are generally complex, constrained and multi

  2. IMPROVE Sample Handling Laboratory SOP 251, Version 2

    E-Print Network [OSTI]

    Fischer, Emily V.

    IMPROVE Sample Handling Laboratory SOP 251, Version 2 TI 251A: Box Cycles and Cartridge Orientation Date: July 17, 2013 Page 1 of 6 TI 251A Box Cycles and Cartridge Orientation Table ...............................................................................................................3 3.3 Proper Cartridge Orientation

  3. Breakthrough Video: Desiccant Enhanced Evaporative Air Conditioning

    SciTech Connect (OSTI)

    2012-01-01

    Researchers at the National Renewable Energy Laboratory (NREL) invented a breakthrough technology that improves air conditioning in a novel way—with heat. NREL combined desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90% less electricity and up to 80% less total energy than traditional air conditioning (AC). This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings.

  4. Cromer Cycle Air Conditioner: A Unique Air-Conditioner Desiccant Cycle to Enhance Dehumidification and Save Energy 

    E-Print Network [OSTI]

    Cromer, C. J.

    2000-01-01

    The Cromer cycle uses a desiccant to move moisture from the saturated air leaving an air conditioning (AC) cooling coil to the air returning to the AC unit from the conditioned space. This has the thermodynamic effect of reducing the overall energy...

  5. Compatible and Cost-Effective Fault Diagnostic Solutions for Air Handling

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative FuelsofProgram:Y-12Power,5Energy Works' Success Opens DoorsComparison of

  6. The Air-Fluorescence Yield

    E-Print Network [OSTI]

    F. Arqueros; F. Blanco; D. Garcia-Pinto; M. Ortiz; J. Rosado

    2008-07-30

    Detection of the air-fluorescence radiation induced by the charged particles of extensive air showers is a well-established technique for the study of ultra-high energy cosmic rays. Fluorescence telescopes provide a nearly calorimetric measure of the primary energy. Presently the main source of systematic uncertainties comes from our limited accuracy in the fluorescence yield, that is, the number of fluorescence photons emitted per unit of energy deposited in the atmosphere by the shower particles. In this paper the current status of our knowledge on the fluorescence yield both experimental an theoretical will be discussed.

  7. Ventilation Air Preconditioning Systems 

    E-Print Network [OSTI]

    Khattar, M.; Brandemuehl, M. J.

    1996-01-01

    Increased outside ventilation air requirements demand special attention to how that air will be conditioned. In winter, the incoming air may need preheating; in summer. the mixed air may be too humid for effective dehumidification. Part...

  8. Air Quality

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 OutreachProductswsicloudwsiclouddenDVA N C E D B L O O D S TA I N P A T T E R N AManaged bynuevo sistemaAir

  9. The Centers for Disease Control and Prevention's Vessel Sanitation Program is proud to bring to you

    E-Print Network [OSTI]

    ­ Ventilation ­ Air Conditioning #12;Air Handling Systems · Construction · Accessible · Inspection · Inspection port acceptable · Maintenance · Cleaning · Self-draining · No standing water #12;Air Conditioning Unit

  10. LM Records Handling System-Freedom of Information/Privacy Act...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Freedom of InformationPrivacy Act, Office of Legacy management LM Records Handling System-Freedom of InformationPrivacy Act, Office of Legacy management LM Records Handling...

  11. Measure Guideline: Air Sealing Mechanical Closets in Slab-On-Grade Homes

    SciTech Connect (OSTI)

    Dickson, B.

    2012-02-01

    This measure guideline describes covers two fundamental retrofit strategies for air sealing around air handling systems that are located within the living space in an enclosed closet: one in which all of the equipment is removed and being replaced, and a closet where the equipment is to remain and existing conditions are sealed. It includes the design and installation details necessary to effectively seal the air handler closet and central return system to maximize the efficiency and safety of the space conditioning system.

  12. Performance of VAV Fan Powered Terminal Units: Experimental Results and Models for Parallel Units 

    E-Print Network [OSTI]

    Furr, J.; O'Neal, D.; Davis, M.; Bryant, J.; Cramlet, A.

    2008-01-01

    Empirical models of airflow output, power consumption, and primary airflow were developed for parallel fan powered variable air volume terminal units at typical operating pres- sures. Both 8 in. (203 mm) and 12 in. (304 mm) primary air inlet terminal units... from three manufacturers were evaluated. Generalized models were developed from the experimental data with coefficients varying by size and manufacturer. Fan power and airflow data were collected at down- stream static pressures over a range from 0...

  13. Performance of VAV Fan Powered Terminal Units: Experimental Results and Models for Series Units 

    E-Print Network [OSTI]

    Furr, J.; O'Neal, D.; Davis, M.; Bryant, J.; Cramlet, A.

    2008-01-01

    Empirical models of airflow output and power consump- tion were developed for series fan powered variable air volume terminal units at typical operating pressures. Terminal units with 8 in. (203 mm) and 12 in. (304 mm) primary air inlets from three different... manufacturers were evaluated. Generalized models were developed from the experimental data with coef- ficients varying by size and manufacturer. Fan power and airflow data were collected at downstream static pressures of 0.25 w.g. (63 Pa). Upstream static...

  14. Arrival condition of spent fuel after storage, handling, and transportation

    SciTech Connect (OSTI)

    Bailey, W.J.; Pankaskie, P.J.; Langstaff, D.C.; Gilbert, E.R.; Rising, K.H.; Schreiber, R.E.

    1982-11-01

    This report presents the results of a study conducted to determine the probable arrival condition of spent light-water reactor (LWR) fuel after handling and interim storage in spent fuel storage pools and subsequent handling and accident-free transport operations under normal or slightly abnormal conditions. The objective of this study was to provide information on the expected condition of spent LWR fuel upon arrival at interim storage or fuel reprocessing facilities or at disposal facilities if the fuel is declared a waste. Results of a literature survey and data evaluation effort are discussed. Preliminary threshold limits for storing, handling, and transporting unconsolidated spent LWR fuel are presented. The difficulty in trying to anticipate the amount of corrosion products (crud) that may be on spent fuel in future shipments is also discussed, and potential areas for future work are listed. 95 references, 3 figures, 17 tables.

  15. Remote-Handled Low Level Waste Disposal Project Alternatives Analysis

    SciTech Connect (OSTI)

    David Duncan

    2010-10-01

    This report identifies, evaluates, and compares alternatives for meeting the U.S. Department of Energy’s mission need for management of remote-handled low-level waste generated by the Idaho National Laboratory and its tenants. Each alternative identified in the Mission Need Statement for the Remote-Handled Low-Level Waste Treatment Project is described and evaluated for capability to fulfill the mission need. Alternatives that could meet the mission need are further evaluated and compared using criteria of cost, risk, complexity, stakeholder values, and regulatory compliance. The alternative for disposal of remote-handled low-level waste that has the highest confidence of meeting the mission need and represents best value to the government is to build a new disposal facility at the Idaho National Laboratory Site.

  16. Metal-Air Batteries

    SciTech Connect (OSTI)

    Zhang, Jiguang; Bruce, Peter G.; Zhang, Gregory

    2011-08-01

    Metal-air batteries have much higher specific energies than most currently available primary and rechargeable batteries. Recent advances in electrode materials and electrolytes, as well as new designs on metal-air batteries, have attracted intensive effort in recent years, especially in the development of lithium-air batteries. The general principle in metal-air batteries will be reviewed in this chapter. The materials, preparation methods, and performances of metal-air batteries will be discussed. Two main metal-air batteries, Zn-air and Li-air batteries will be discussed in detail. Other type of metal-air batteries will also be described.

  17. Certification document for newly generated contact-handled transuranic waste

    SciTech Connect (OSTI)

    Box, W.D.; Setaro, J.

    1984-01-01

    The US Department of Energy has requested that all national laboratories handling defense waste develop and augment a program whereby all newly generated contact-handled transuranic (TRU) waste be contained, stored, and then shipped to the Waste Isolation Pilot Plant (WIPP) in accordance with the requirements set forth in WIPP-DOE-114. The program described in this report delineates how Oak Ridge National Laboratory intends to comply with these requirements and lists the procedures used by each generator to ensure that their TRU wastes are certifiable for shipment to WIPP.

  18. Evaluation of a New Remote Handling Design for High Throughput Annular Centrifugal Contactors

    SciTech Connect (OSTI)

    David H. Meikrantz; Troy G. Garn; Jack D. Law; Lawrence L. Macaluso

    2009-09-01

    Advanced designs of nuclear fuel recycling plants are expected to include more ambitious goals for aqueous based separations including; higher separations efficiency, high-level waste minimization, and a greater focus on continuous processes to minimize cost and footprint. Therefore, Annular Centrifugal Contactors (ACCs) are destined to play a more important role for such future processing schemes. Previous efforts defined and characterized the performance of commercial 5 cm and 12.5 cm single-stage ACCs in a “cold” environment. The next logical step, the design and evaluation of remote capable pilot scale ACCs in a “hot” or radioactive environment was reported earlier. This report includes the development of remote designs for ACCs that can process the large throughput rates needed in future nuclear fuel recycling plants. Novel designs were developed for the remote interconnection of contactor units, clean-in-place and drain connections, and a new solids removal collection chamber. A three stage, 12.5 cm diameter rotor module has been constructed and evaluated for operational function and remote handling in highly radioactive environments. This design is scalable to commercial CINC ACC models from V-05 to V-20 with total throughput rates ranging from 20 to 650 liters per minute. The V-05R three stage prototype was manufactured by the commercial vendor for ACCs in the U.S., CINC mfg. It employs three standard V-05 clean-in-place (CIP) units modified for remote service and replacement via new methods of connection for solution inlets, outlets, drain and CIP. Hydraulic testing and functional checks were successfully conducted and then the prototype was evaluated for remote handling and maintenance suitability. Removal and replacement of the center position V-05R ACC unit in the three stage prototype was demonstrated using an overhead rail mounted PaR manipulator. This evaluation confirmed the efficacy of this innovative design for interconnecting and cleaning individual stages while retaining the benefits of commercially reliable ACC equipment for remote applications in the nuclear industry. Minor modifications and suggestions for improved manual remote servicing by the remote handling specialists were provided but successful removal and replacement was demonstrated in the first prototype.

  19. Residential Forced Air System Cabinet Leakage and Blower Performance

    SciTech Connect (OSTI)

    Walker, Iain S.; Dickerhoff, Darryl J.; Delp, William W.

    2010-03-01

    This project evaluated the air leakage and electric power consumption of Residential HVAC components, with a particular focus on air leakage of furnace cabinets. Laboratory testing of HVAC components indicated that air leakage can be significant and highly variable from unit to unit ? indicating the need for a standard test method and specifying maximum allowable air leakage in California State energy codes. To further this effort, this project provided technical assistance for the development of a national standard for Residential HVAC equipment air leakage. This standard is being developed by ASHRAE and is called"ASHRAE Standard 193P - Method of test for Determining the Air Leakage Rate of HVAC Equipment". The final part of this project evaluated techniques for measurement of furnace blower power consumption. A draft test procedure for power consumption was developed in collaboration with the Canadian General Standards Board: CSA 823"Performance Standard for air handlers in residential space conditioning systems".

  20. Air temperature thresholds for indoor comfort and perceived air quality

    E-Print Network [OSTI]

    Zhang, Hui; Edward, Arens; Pasut, Wilmer

    2012-01-01

    in the Netherlands, Indoor Air 2, 127 – 136. BuildingPaliaga, G. (2009) Moving air for comfort. ASHRAE Journal,ventilation system on perceived air quality, Indoor Air

  1. Moving air for comfort

    E-Print Network [OSTI]

    Arens, Edward; Turner, Stephen; Zhang, Hui; Paliaga, Gwelen

    2009-01-01

    Brager, L. Zagreus. 2007, “Air movement preferences observed709-731. 9. Toftum, J. 2004. “Air movement – good or bad? ”Indoor Air 14, pp 40-45. 10. Gong, N. , K. Tham, A. Melikov,

  2. Feasibility of air capture

    E-Print Network [OSTI]

    Ranjan, Manya

    2010-01-01

    Capturing CO2 from air, referred to as Air Capture, is being proposed as a viable climate change mitigation technology. The two major benefits of air capture, reported in literature, are that it allows us to reduce the ...

  3. Method of preparing and handling chopped plant materials

    DOE Patents [OSTI]

    Bransby, David I. (2668 Wire Rd., Auburn, AL 36832)

    2002-11-26

    The method improves efficiency of harvesting, storage, transport, and feeding of dry plant material to animals, and is a more efficient method for harvesting, handling and transporting dry plant material for industrial purposes, such as for production of bioenergy, and composite panels.

  4. Structural acceptance criteria Remote Handling Building Tritium Extraction Facility

    SciTech Connect (OSTI)

    Mertz, G.

    1999-12-16

    This structural acceptance criteria contains the requirements for the structural analysis and design of the Remote Handling Building (RHB) in the Tritium Extraction Facility (TEF). The purpose of this acceptance criteria is to identify the specific criteria and methods that will ensure a structurally robust building that will safely perform its intended function and comply with the applicable Department of Energy (DOE) structural requirements.

  5. A NOVEL MATERIAL HANDLING TECHNOLOGY Witaya Wannasuphoprasit1

    E-Print Network [OSTI]

    Amaral, Luis A.N.

    COBOTS: A NOVEL MATERIAL HANDLING TECHNOLOGY Witaya Wannasuphoprasit1 Prasad Akella2 Michael 2 General Motors Corporation, Manufacturing Center, M/C: 480-109-163, Warren, MI 48090-9040 ABSTRACT, highlighted in this paper, is a solution to the so-called "inertia management" problem which arises frequently

  6. How the Forest handles stormwater: 15% surface water runoff

    E-Print Network [OSTI]

    Virginia Tech

    or contaminants present on the parking lot such as hydrocarbons, silt, salt, and nutrients, and deposits them1 #12;How the Forest handles stormwater: 15% surface water runoff 35% surface water detained or infiltrated 50% evapotranspiration In developed conditions: 5570% surface water runoff 15% surface water

  7. Handling Database Updates in Two-dimensional Temporal Logic

    E-Print Network [OSTI]

    Finger, Marcelo

    Handling Database Updates in Two-dimensional Temporal Logic Marcelo Finger y Department (Draft version 0.2) Abstract This paper deals with the description of the evolution of the understanding in database systems due to updates. For this purpose, we introduce a two-dimensional temporal logic

  8. Type Handling in a Fully Integrated Programming and Specification Language

    E-Print Network [OSTI]

    Leavens, Gary T.

    Type Handling in a Fully Integrated Programming and Specification Language Gregory Kulczycki of component-based software requires languages that integrate programming and specification features, and types are at the heart of this integration. Programming languages are not suited for specification, and specification

  9. Handling Advertisements of Unknown Quality in Search Advertising

    E-Print Network [OSTI]

    Olston, Christopher

    Handling Advertisements of Unknown Quality in Search Advertising Sandeep Pandey Christopher Olston@yahoo-inc.com Abstract We consider how a search engine should select advertisements to display with search results well the displayed advertisements appeal to users. The main difficulty stems from new ad- vertisements

  10. "Developing the infrastructure and skills needed to handle big data."

    E-Print Network [OSTI]

    Zhigilei, Leonid V.

    "Developing the infrastructure and skills needed to handle big data." Don Brown W.S. Calcott Engineering University of Virginia Charlottesville, VA 434.982.2074 Big Data Research Group Our research group and uncertain behaviors. Methodological interests in these areas include data- mining, simulation

  11. Family and Consumer Sciences Safe Handling and Preparation

    E-Print Network [OSTI]

    Fernandez, Eduardo

    Family and Consumer Sciences FSFCS100 Safe Handling and Preparation of Fish and Shellfish. Fish should have bright eyes that are clear and protruding. The skin should be bright and shiny, not "fishy." Gills should be pink or bright red and free of slime. Fresh fish steaks and fillets should

  12. Sampling device with a capped body and detachable handle

    DOE Patents [OSTI]

    Jezek, Gerd-Rainer (Orchard Park, NY)

    2000-01-01

    The apparatus is a sampling device having a pad for sample collection, a body which supports the pad, a detachable handle connected to the body and a cap which encloses and retains the pad and body to protect the integrity of the sample.

  13. Design package for fuel retrieval system fuel handling tool modification

    SciTech Connect (OSTI)

    TEDESCHI, D.J.

    1998-11-09

    This is a design package that contains the details for a modification to a tool used for moving fuel elements during loading of MCO Fuel Baskets for the Fuel Retrieval System. The tool is called the fuel handling tool (or stinger). This document contains requirements, development design information, tests, and test reports.

  14. Design package for fuel retrieval system fuel handling tool modification

    SciTech Connect (OSTI)

    TEDESCHI, D.J.

    1999-03-17

    This is a design package that contains the details for a modification to a tool used for moving fuel elements during loading of MCO Fuel Baskets for the Fuel Retrieval System. The tool is called the fuel handling tool (or stinger). This document contains requirements, development design information, tests, and test reports.

  15. Design Package for Fuel Retrieval System Fuel Handling Tool Modification

    SciTech Connect (OSTI)

    TEDESCHI, D.J.

    2000-03-27

    This is a design package that contains the details for a modification to a tool used for moving fuel elements during loading of MCO Fuel Baskets for the Fuel Retrieval System. The tool is called the fuel handling tool (or stinger). This document contains requirements, development design information, tests, and test reports.

  16. Integrated Ice Storage/Sprinkler HVAC System Sharply Cuts Energy Costs and Air-Distribution First Costs 

    E-Print Network [OSTI]

    Meckler, G.

    1986-01-01

    by distributing a small quantity (0.1 to 0.2 cfm/sq ft) of very dry, 40°F primary air. All dehumidification is handled by the ice-chilled primary air, which is distributed in variable, volume, determined by the space dehumidification requirement, to fan-coil...

  17. Primary zone air proportioner

    DOE Patents [OSTI]

    Cleary, Edward N. G. (San Diego, CA)

    1982-10-12

    An air proportioner is provided for a liquid hydrocarbon fueled gas turbine of the type which is convertible to oil gas fuel and to coal gas fuel. The turbine includes a shell for enclosing the turbine, an air duct for venting air in said shell to a gasifier, and a fuel injector for injecting gasified fuel into the turbine. The air proportioner comprises a second air duct for venting air from the air duct for mixing with fuel from the gasifier. The air can be directly injected into the gas combustion basket along with the fuel from the injector or premixed with fuel from the gasifier prior to injection by the fuel injector.

  18. Biological Air Emissions Control

    Office of Energy Efficiency and Renewable Energy (EERE)

    Air quality standards are becoming more stringent for the U.S. wood products industry. Emissions of volatile organic compounds (VOCs) and hazardous air pollutants (HAPs) (including methanol,...

  19. Chapter 21 Air Quality

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    are in the PortlandVancouver metro area where there are more industrial sources of air pollution and higher levels of traffic congestion that create more air emissions....

  20. University of Michigan Ann Arbor Campus Exterior Elements Design Review Committee

    E-Print Network [OSTI]

    Kamat, Vineet R.

    , materials, noise, etc. exhaust vents, cooling towers, air-handling and condensing units Page 1 of 2 #12

  1. Unit and student details Unit code Unit title

    E-Print Network [OSTI]

    Sekercioglu, Y. Ahmet

    Unit and student details Unit code Unit title If this is a group assignment, each student must submitted Has any part of this assessment been previously submitted as part of another unit/course? Yes not be copied. No part of this assignment has been previously submitted as part of another unit/course. I

  2. A geophysical shock and air blast simulator at the National Ignition...

    Office of Scientific and Technical Information (OSTI)

    of Publication: United States Language: English Subject: 46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 70 PLASMA PHYSICS AND FUSION TECHNOLOGY; AIR; ATMOSPHERIC...

  3. Unit Unit Desc Unit Unit Desc Program Program Desc OLD ACCOUNT FORMAT NEW ACCOUNT FORMAT

    E-Print Network [OSTI]

    Unit Unit Desc Unit Unit Desc Program Program Desc OLD ACCOUNT FORMAT NEW ACCOUNT FORMAT 001113 AP Old O/S A/P NonResCk 0000 General 000000 General #12;Unit Unit Desc Unit Unit Desc Program Program

  4. Testing and Economic Evaluation of a High Efficiency 10-ton Rooftop Air Conditioner 

    E-Print Network [OSTI]

    O'Neal, D. L.; Davis, M. A.

    2006-11-09

    In 1993, the U.S. Environmental Protection Agency initiated a project to design, build and demonstrate a high efficiency commercial rooftop air conditioning unit. The unit was designed by Hibberd Consulting of Westminster, Colorado, and was built...

  5. Portfolio management in the Air Force : current status and opportunities

    E-Print Network [OSTI]

    Morgan, Dave B

    2011-01-01

    There are hundreds of weapons programs, under the management of the United States Air Force worth billions of dollars. These programs are being developed to fulfill a need in the U.S. defense strategy. Bringing these weapon ...

  6. Development of an autonomous robotic air hockey player

    E-Print Network [OSTI]

    Vang, Bee, S.B. Massachusetts Institute of Technology

    2013-01-01

    Air hockey is a widely played sport in the United States and is expanding to other countries. It is usually played on a frictionless table between two or more people. The dependency of another individual makes it impossible ...

  7. Concepts studies for future intracity air transportation systems

    E-Print Network [OSTI]

    Joint DOT-NASA Civil Aviation Research and Development Policy Study.; United States. National Aeronautics and Space Administration; Massachusetts Institute of Technology. Flight Transportation Laboratory

    1970-01-01

    Summary: This report is concerned with describing the possible application of future air transportation systems within urban areas of the United States. The planning horizon extends to 1995 and the report focuses on the ...

  8. Air Pollution Spring 2010

    E-Print Network [OSTI]

    Pierce, Jeffrey

    ATS 555 Air Pollution Spring 2010 T Th 11:00 ­ 12:15, NESB 101 Instructor: Prof. Sonia Kreidenweis an understanding of types and sources of air pollution. 2. Examine concentrations of air pollutants and their effects on health and welfare. Review regulations governing air pollution. 3. Examine the meteorological

  9. Cromer Cycle Air Conditioner

    Office of Energy Efficiency and Renewable Energy (EERE)

    New Air Conditioning System Uses Desiccant to Transfer Moisture and Increase Efficiency and Capacity

  10. DEVELOPMENT OF A TAMPER RESISTANT/INDICATING AEROSOL COLLECTION SYSTEM FOR ENVIRONMENTAL SAMPLING AT BULK HANDLING FACILITIES

    SciTech Connect (OSTI)

    Sexton, L.

    2012-06-06

    Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity to collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI), Office of Nonproliferation and International Security (NIS), National Nuclear Security Administration (NNSA).

  11. GEOPHYSICAL RESEARCH LETTERS, VOL. 27, NO. 21, PAGES 3465-3468, NOVEMBER 1, 2000 Increasing background ozone in surface air

    E-Print Network [OSTI]

    Lin, C.-Y. Cynthia

    that an important consideration for pollution control strategies is the O3 back- ground present in surface air over background ozone in surface air over the United States C.-Y. Cynthia Lin, Daniel J. Jacob, J. William Munger in surface air over the United States from 1980 to 1998 is examined using monthly probability distributions

  12. Liquid class predictor for liquid handling of complex mixtures

    DOE Patents [OSTI]

    Seglke, Brent W. (San Ramon, CA); Lekin, Timothy P. (Livermore, CA)

    2008-12-09

    A method of establishing liquid classes of complex mixtures for liquid handling equipment. The mixtures are composed of components and the equipment has equipment parameters. The first step comprises preparing a response curve for the components. The next step comprises using the response curve to prepare a response indicator for the mixtures. The next step comprises deriving a model that relates the components and the mixtures to establish the liquid classes.

  13. Health physics considerations in UF{sub 6} handling

    SciTech Connect (OSTI)

    Bailey, J.C. [Norway Assoicates, Inc., Oak Ridge, TN (United States)

    1991-12-31

    Uranium is a radioactive substance that emits alpha particles and very small amounts of gamma radiation. Its daughter products emit beta and gamma radiation. In uranium handling operations these are the radiations one must consider. This presentation will review the characteristics of the radiations, the isotopes from which they originate, the growth and decay of the uranium daughter products, and some specific health physics practices dictated by these factors.

  14. AD : Airworthiness Directive ADC : Air Data Computer

    E-Print Network [OSTI]

    Ladkin, Peter B.

    Reference Unit LAND : Landing LATC : London Air Traffic Control L/D : Landing LIG : Landing Gear LOC and Test Panel NAV : Navigation NPA : Non Precision Approach NTSB : National Transportation Safety Board : Thrust Control Computer TCD : Ministry of Transport Civil Aviation Bureau Directive TFC : Traffic THR

  15. UNITED STEELWORKERS

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking With WIPP UPDATE:Administrationfollowing tableUNITED FERC

  16. United States

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirley Ann Jackson About1996HowFOAShowing YouNeedof EnergyMeeting - MarchUSPS:1 United States

  17. United States

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirley Ann Jackson About1996HowFOAShowing YouNeedof EnergyMeeting - MarchUSPS:1 United States7

  18. United States

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirley Ann Jackson About1996HowFOAShowing YouNeedof EnergyMeeting - MarchUSPS:1 United States78

  19. United States

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirley Ann Jackson About1996HowFOAShowing YouNeedof EnergyMeeting - MarchUSPS:1 United

  20. United States

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirley Ann Jackson About1996HowFOAShowing YouNeedof EnergyMeeting - MarchUSPS:1 UnitedDuke-4-E

  1. Indoor unit for electric heat pump

    DOE Patents [OSTI]

    Draper, Robert (Churchill, PA); Lackey, Robert S. (Pittsburgh, PA); Fagan, Jr., Thomas J. (Penn HIlls, PA); Veyo, Stephen E. (Murrysville, PA); Humphrey, Joseph R. (Grand Rapids, MI)

    1984-01-01

    An indoor unit for an electric heat pump is provided in modular form including a refrigeration module 10, an air mover module 12, and a resistance heat package module 14, the refrigeration module including all of the indoor refrigerant circuit components including the compressor 36 in a space adjacent the heat exchanger 28, the modules being adapted to be connected to air flow communication in several different ways as shown in FIGS. 4-7 to accommodate placement of the unit in various orientations.

  2. Air Pollution Impacts on Ecosystems and Biological Diversity

    E-Print Network [OSTI]

    Air Pollution Impacts on Ecosystems and Biological Diversity in the Eastern United States Threats CITATION Lovett, G.M., and T.H. Tear. 2008. Threats from Above: Air Pollution Impacts on Ecosystems and nitrogen pollution. © Eric Middelkoop/BigStockPhoto.com Botom: A newly hatched common loon chick is watched

  3. Air Conditioner Compressor Performance Model

    SciTech Connect (OSTI)

    Lu, Ning; Xie, YuLong; Huang, Zhenyu

    2008-09-05

    During the past three years, the Western Electricity Coordinating Council (WECC) Load Modeling Task Force (LMTF) has led the effort to develop the new modeling approach. As part of this effort, the Bonneville Power Administration (BPA), Southern California Edison (SCE), and Electric Power Research Institute (EPRI) Solutions tested 27 residential air-conditioning units to assess their response to delayed voltage recovery transients. After completing these tests, different modeling approaches were proposed, among them a performance modeling approach that proved to be one of the three favored for its simplicity and ability to recreate different SVR events satisfactorily. Funded by the California Energy Commission (CEC) under its load modeling project, researchers at Pacific Northwest National Laboratory (PNNL) led the follow-on task to analyze the motor testing data to derive the parameters needed to develop a performance models for the single-phase air-conditioning (SPAC) unit. To derive the performance model, PNNL researchers first used the motor voltage and frequency ramping test data to obtain the real (P) and reactive (Q) power versus voltage (V) and frequency (f) curves. Then, curve fitting was used to develop the P-V, Q-V, P-f, and Q-f relationships for motor running and stalling states. The resulting performance model ignores the dynamic response of the air-conditioning motor. Because the inertia of the air-conditioning motor is very small (H<0.05), the motor reaches from one steady state to another in a few cycles. So, the performance model is a fair representation of the motor behaviors in both running and stalling states.

  4. The PAMELA Storage and Control Unit M. Casolino a,*, F. Altamura a

    E-Print Network [OSTI]

    Morselli, Aldo

    The PAMELA Storage and Control Unit M. Casolino a,*, F. Altamura a , A. Basili a , M.P. De Pascale Galaxy in the form of high energy particles; in the same time it will measure the galactic, solar of the instrument ­ including data storage ­ are handled by the PAMELA Storage and Control Unit (PSCU), which

  5. Integrated Technology Air Cleaners (ITAC): Design and Evaluation

    SciTech Connect (OSTI)

    Fisk, William J.; Cohn, Sebastian; Destaillats, Hugo; Henzel, Victor; Sidheswaran, Meera; Sullivan, Douglas P.

    2013-09-13

    The primary objective of this project was to design, build, and test an air cleaner for residential use with the potential to substantially improve indoor air quality, or maintain indoor air quality unchanged, when outdoor air ventilation rates are reduced to save energy. Two air cleaners were designed and fabricated. The design targets for airflow rate, fan power, and projected cost were met. In short term laboratory studies, both units performed as expected; however, during field studies in homes, the formaldehyde removal performance of the air cleaners was much lower than expected. In subsequent laboratory studies, incomplete decomposition of some indoor air volatile organic compounds, with formaldehyde as a product of partial decomposition of volatile organic compounds, was confirmed as the explanation for the poor formaldehyde removal performance in the field studies. The amount of formaldehyde produced per unit of decomposition of other volatile organic compounds was substantially diminished by increasing the amount of catalyst on the filter and also by decreasing the air velocity. Together, these two measures reduced formaldehyde production, per unit destruction of other volatile organic compounds, by a factor of four, while increasing the removal efficiency of volatile organic compounds by a factor of 1.4. A company with a southern California office is conducting studies in conjunction with Lawrence Berkeley National Laboratory, with the goal of incorporating the ITAC catalytic air cleaning technology in their future commercial products.

  6. Feasibiltiy of Power and Particle Handling in an ST-FNSF and...

    Office of Scientific and Technical Information (OSTI)

    Feasibiltiy of Power and Particle Handling in an ST-FNSF and the Effects of Divertor Geometry Citation Details In-Document Search Title: Feasibiltiy of Power and Particle Handling...

  7. Failure Inferencing based Fast Rerouting for Handling Transient Link and Node Failures

    E-Print Network [OSTI]

    Nelakuditi, Srihari

    generation, propagation, and processing mechanisms. MPLS based approaches [5] handle transient failures1 Failure Inferencing based Fast Rerouting for Handling Transient Link and Node Failures Zifei network with high service availability. Unfortunately, in today's Internet, transient failures occur

  8. Current and historical trends in general aviation in the United States

    E-Print Network [OSTI]

    Shetty, Kamala Irene

    2012-01-01

    General aviation (GA) is an important component of aviation in the United States. In 2011, general aviation and air taxi operations represented 63% of all towered operations in the United States, while commercial aviation ...

  9. " Million Housing Units, Final...

    U.S. Energy Information Administration (EIA) Indexed Site

    " 1Total U.S. includes all primary occupied housing units in the 50 States and the District of Columbia. Vacant housing units, seasonal units, second homes, military...

  10. United States Environmental

    E-Print Network [OSTI]

    Al Faruque, Mohammad Abdullah

    Protect Your Family From Lead in Your Home United States Environmental Protection Agency United States Consumer Product Safety Commission United States Department of Housing and Urban Development

  11. Enhancing the use of coals by gas reburning-sorbent injection: Volume 3 -- Gas reburning-sorbent injection at Edwards Unit 1, Central Illinois Light Company. Final report

    SciTech Connect (OSTI)

    NONE

    1996-03-01

    Design work has been completed for a Gas Reburning-Sorbent Injection (GR-SI) system to reduce emissions of NO{sub x} and SO{sub 2} from a wall fired unit at Central Illinois Light Company`s Edwards Station Unit 1, located in Bartonville, Illinois. The goal of the project was to reduce emissions of NO{sub x} by 60%, from the as found baseline of 0.98 lb/MBtu and to reduce emissions of SO{sub 2} by 50%. Since the unit currently fires a blend of high sulfur Illinois coal and low sulfur Kentucky coal to meet an SO{sub 2} limit of 1.8 lb/MBtu, the goal at this site was amended to meeting this limit while increasing the fraction of high sulfur coal to 57% from the current 15% level. GR-SI requires injection of natural gas into the furnace at the level of the top burner row, creating a fuel-rich zone in which NO{sub x} formed in the coal zone is reduced to N{sub 2}. Recycled flue gas is used to increase the reburning fuel jet momentum, resulting in enhanced mixing. Recycled flue gas is also used to cool the top row of burners which would not be in service during GR operation. Dry hydrated lime sorbent is injected into the upper furnace to react with SO{sub 2}, forming solid CaSO{sub 4} and CaSO{sub 3}, which are collected by the ESP. The system was designed to inject sorbent at a rate corresponding to a calcium (sorbent) to sulfur (coal) molar ratio of 2.0. The SI system design was optimized with respect to gas temperature, injection air flow rate, and sorbent dispersion. Sorbent injection air flow is equal to 3% of the combustion air. The design includes modifications of the ESP, sootblowing, and ash handling systems.

  12. Natural ventilation possibilities for buildings in the United States

    E-Print Network [OSTI]

    Dean, Brian N. (Brian Nathan), 1974-

    2001-01-01

    In the United States, many of the commercial buildings built in the last few decades are completely mechanically air conditioned, without the capability to use natural ventilation. This habit has occurred in building designs ...

  13. Performance of ECM controlled VAV fan powered terminal units 

    E-Print Network [OSTI]

    Cramlet, Andrew Charles

    2009-05-15

    Empirical performance models of fan airflow, primary airflow and power consumption were developed for series and parallel variable air volume fan powered terminal units. An experimental setup and test procedure were created to test the terminal...

  14. Alternative Air Conditioning Technologies: Underfloor Air Distribution (UFAD)

    E-Print Network [OSTI]

    Webster, Tom

    2004-01-01

    Refrigerating, and Air-Conditioning Engineers, Inc, 1992.Refrigerating, and Air-Conditioning Engineers, Inc. , 1992.Refrigerating, and Air-Conditioning Engineers, Inc. , 1990.

  15. Energy and economic assessment of desiccant cooling systems coupled with single glazed air and hybrid PV/thermal solar collectors for applications in hot and humid climate

    SciTech Connect (OSTI)

    Beccali, Marco; Finocchiaro, Pietro; Nocke, Bettina

    2009-10-15

    This paper presents a detailed analysis of the energy and economic performance of desiccant cooling systems (DEC) equipped with both single glazed standard air and hybrid photovoltaic/thermal (PV/t) collectors for applications in hot and humid climates. The use of 'solar cogeneration' by means of PV/t hybrid collectors enables the simultaneous production of electricity and heat, which can be directly used by desiccant air handling units, thereby making it possible to achieve very energy savings. The present work shows the results of detailed simulations conducted for a set of desiccant cooling systems operating without any heat storage. System performance was investigated through hourly simulations for different systems and load combinations. Three configurations of DEC systems were considered: standard DEC, DEC with an integrated heat pump and DEC with an enthalpy wheel. Two kinds of building occupations were considered: office and lecture room. Moreover, three configurations of solar-assisted air handling units (AHU) equipped with desiccant wheels were considered and compared with standard AHUs, focusing on achievable primary energy savings. The relationship between the solar collector's area and the specific primary energy consumption for different system configurations and building occupation patterns is described. For both occupation patterns, sensitivity analysis on system performance was performed for different solar collector areas. Also, this work presents an economic assessment of the systems. The cost of conserved energy and the payback time were calculated, with and without public incentives for solar cooling systems. It is worth noting that the use of photovoltaics, and thus the exploitation of related available incentives in many European countries, could positively influence the spread of solar air cooling technologies (SAC). An outcome of this work is that SAC systems equipped with PV/t collectors are shown to have better performance in terms of primary energy saving than conventional systems fed by vapour compression chillers and coupled with PV cells. All SAC systems present good figures for primary energy consumption. The best performances are seen in systems with integrated heat pumps and small solar collector areas. The economics of these SAC systems at current equipment costs and energy prices are acceptable. They become more interesting in the case of public incentives of up to 30% of the investment cost (Simple Payback Time from 5 to 10 years) and doubled energy prices. (author)

  16. General Air Permits (Louisiana)

    Broader source: Energy.gov [DOE]

    Any source, including a temporary source, which emits or has the potential to emit any air contaminant requires an air permit. Facilities with potential emissions less than 5 tons per year of any...

  17. Viability of Existing INL Facilities for Dry Storage Cask Handling

    SciTech Connect (OSTI)

    Randy Bohachek; Charles Park; Bruce Wallace; Phil Winston; Steve Marschman

    2013-04-01

    This report evaluates existing capabilities at the INL to determine if a practical and cost effective method could be developed for opening and handling full-sized dry storage casks. The Idaho Nuclear Technology and Engineering Center (INTEC) CPP-603, Irradiated Spent Fuel Storage Facility, provides the infrastructure to support handling and examining casks and their contents. Based on a reasonable set of assumptions, it is possible to receive, open, inspect, remove samples, close, and reseal large bolted-lid dry storage casks at the INL. The capability can also be used to open and inspect casks that were last examined at the TAN Hot Shop over ten years ago. The Castor V/21 and REA-2023 casks can provide additional confirmatory information regarding the extended performance of low-burnup (<45 GWD/MTU) used nuclear fuel. Once a dry storage cask is opened inside CPP-603, used fuel retrieved from the cask can be packaged in a shipping cask, and sent to a laboratory for testing. Testing at the INL’s Materials and Fuels Complex (MFC) can occur starting with shipment of samples from CPP-603 over an on-site road, avoiding the need to use public highways. This reduces cost and reduces the risk to the public. The full suite of characterization methods needed to establish the condition of the fuel exists and MFC. Many other testing capabilities also exist at MFC, but when those capabilities are not adequate, samples can be prepared and shipped to other laboratories for testing. This report discusses how the casks would be handled, what work needs to be done to ready the facilities/capabilities, and what the work will cost.

  18. Viability of Existing INL Facilities for Dry Storage Cask Handling

    SciTech Connect (OSTI)

    Bohachek, Randy; Wallace, Bruce; Winston, Phil; Marschman, Steve

    2013-04-30

    This report evaluates existing capabilities at the INL to determine if a practical and cost effective method could be developed for opening and handling full-sized dry storage casks. The Idaho Nuclear Technology and Engineering Center (INTEC) CPP-603, Irradiated Spent Fuel Storage Facility, provides the infrastructure to support handling and examining casks and their contents. Based on a reasonable set of assumptions, it is possible to receive, open, inspect, remove samples, close, and reseal large bolted-lid dry storage casks at the INL. The capability can also be used to open and inspect casks that were last examined at the TAN Hot Shop over ten years ago. The Castor V/21 and REA-2023 casks can provide additional confirmatory information regarding the extended performance of low-burnup (<45 GWD/MTU) used nuclear fuel. Once a dry storage cask is opened inside CPP-603, used fuel retrieved from the cask can be packaged in a shipping cask, and sent to a laboratory for testing. Testing at the INL’s Materials and Fuels Complex (MFC) can occur starting with shipment of samples from CPP-603 over an on-site road, avoiding the need to use public highways. This reduces cost and reduces the risk to the public. The full suite of characterization methods needed to establish the condition of the fuel exists and MFC. Many other testing capabilities also exist at MFC, but when those capabilities are not adequate, samples can be prepared and shipped to other laboratories for testing. This report discusses how the casks would be handled, what work needs to be done to ready the facilities/capabilities, and what the work will cost.

  19. 327 Building liquid waste handling options modification project plan

    SciTech Connect (OSTI)

    Ham, J.E.

    1998-03-28

    This report evaluates the modification options for handling radiological liquid waste (RLW) generated during decontamination and cleanout of the 327 Building. The overall objective of the 327 Facility Stabilization Project is to establish a passively safe and environmentally secure configuration of the 327 Facility. The issue of handling of RLW from the 327 Facility (assuming the 34O Facility is not available to accept the RLW) has been conceptually examined in at least two earlier engineering studies (Parsons 1997a and Hobart l997). Each study identified a similar preferred alternative that included modifying the 327 Facility RLWS handling systems to provide a truck load-out station, either within the confines of the facility or exterior to the facility. The alternatives also maximized the use of existing piping, tanks, instrumentation, controls and other features to minimize costs and physical changes. An issue discussed in each study involved the anticipated volume of the RLW stream. Estimates ranged between 113,550 and 387,500 liters in the earlier studies. During the development of the 324/327 Building Stabilization/Deactivation Project Management Plan, the lower estimate of approximately 113,550 liters was confirmed and has been adopted as the baseline for the 327 Facility RLW stream. The goal of this engineering study is to reevaluate the existing preferred alternative and select a new preferred alternative, if appropriate. Based on the new or confirmed preferred alternative, this study will also provide a conceptual design and cost estimate for required modifications to the 327 Facility to allow removal of RLWS and treatment of the RLW generated during deactivation.

  20. CWS-Fired Residential Warm-Air Heating System. Quarterly report, February 1, 1989--April 30, 1989

    SciTech Connect (OSTI)

    Balsavich, J.; Becker, F.E.; Smolensky, L.A.

    1989-07-01

    During the report period, work continued on the life-cycle testing, optimization and refining of the second-generation furnace assembly, which comprises all the major furnace components: The combustor, heat exchanger, and baghouse, as well as the auxiliary subsystems. The furnace has operated for about 90 hours, and has burned 1,000 pounds of CWS. During testing, the only maintenance that was performed on the system was to clean the bag filters to obtain ash samples for analysts. Concurrent with testing the second-generation furnace, fabrication and assembly of the third-generation furnace was completed, and a life-cycle testing and optimization process for this furnace has started. In contrast to the second-generation furnace, which was designed more as an experimental unit, the third-generation furnace is a stand-alone heating unit Incorporating the standard air handling system, blower, pump, and control box as part of the furnace. During the report period, the third-generation furnace operated for a total of 35 hours, and burned more than 300 pounds of CWS, with average tests lasting 6 hours. During the next quarter, life-cycle testing of the third-generation furnace will continue to identify areas needing further development.

  1. The Technical and Economical Analysis of the Air-conditioning System Usage in Residential Buildings in Beijing 

    E-Print Network [OSTI]

    Sheng, G.; Xie, G.

    2006-01-01

    -conditioning units in residential buildings, and are using the central air-conditioning system in residential buildings. To determine the best air conditioning mode, a residential tower building with 22 layers was chosen for analysis. The advantages and disadvantages...

  2. Enhancing the use of coals by gas reburning-sorbent injection. Volume 3, Gas reburning-sorbent injection at Edwards Unit 1, Central Illinois Light Company

    SciTech Connect (OSTI)

    NONE

    1994-10-01

    Design work has been completed for a Gas Reburning-Sorbent Injection (GR-SI) system to reduce emissions of NO{sub x}, and SO{sub 2} from a wall fired unit. A GR-SI system was designed for Central Illinois Light Company`s Edwards Station Unit 1, located in Bartonville, Illinois. The unit is rated at 117 MW(e) (net) and is front wall fired with a pulverized bituminous coal blend. The goal of the project was to reduce emissions of NO{sub x} by 60%, from the ``as found`` baseline of 0.98 lb/MBtu (420 mg/MJ), and to reduce emissions of S0{sub 2} by 50%. Since the unit currently fires a blend of high sulfur Illinois coal and low sulfur Kentucky coal to meet an S0{sub 2} limit Of 1.8 lb/MBtu (770 mg/MJ), the goal at this site was amended to meeting this limit while increasing the fraction of high sulfur coal to 57% from the current 15% level. GR-SI requires injection of natural gas into the furnace at the level of the top burner row, creating a fuel-rich zone in which NO{sub x} formed in the coal zone is reduced to N{sub 2}. The design natural gas input corresponds to 18% of the total heat input. Burnout (overfire) air is injected at a higher elevation to burn out fuel combustible matter at a normal excess air level of 18%. Recycled flue gas is used to increase the reburning fuel jet momentum, resulting in enhanced mixing. Recycled flue gas is also used to cool the top row of burners which would not be in service during GR operation. Dry hydrated lime sorbent is injected into the upper furnace to react with S0{sub 2}, forming solid CaSO{sub 4} and CaSO{sub 3}, which are collected by the ESP. The SI system design was optimized with respect to gas temperature, injection air flow rate, and sorbent dispersion. Sorbent injection air flow is equal to 3% of the combustion air. The design includes modifications of the ESP, sootblowing, and ash handling systems.

  3. Uranium hexafluoride: Safe handling, processing, and transporting: Conference proceedings

    SciTech Connect (OSTI)

    Strunk, W.D.; Thornton, S.G. (eds.)

    1988-01-01

    This conference seeks to provide a forum for the exchange of information and ideas of the safety aspects and technical issue related to the handling of uranium hexafluoride. By allowing operators, engineers, scientists, managers, educators, and others to meet and share experiences of mutual concern, the conference is also intended to provide the participants with a more complete knowledge of technical and operational issues. The topics for the papers in the proceedings are widely varied and include the results of chemical, metallurgical, mechanical, thermal, and analytical investigations, as well as the developed philosophies of operational, managerial, and regulatory guidelines. Papers have been entered individually into EDB and ERA. (LTN)

  4. Duct Remediation Program: Material characterization and removal/handling

    SciTech Connect (OSTI)

    Beckman, T.d.; Davis, M.M.; Karas, T.M.

    1992-11-01

    Remediation efforts were successfully performed at Rocky Flats to locate, characterize, and remove plutonium holdup from process exhaust ducts. Non-Destructive Assay (NDA) techniques were used to determine holdup locations and quantities. Visual characterization using video probes helped determine the physical properties of the material, which were used for remediation planning. Assorted equipment types, such as vacuum systems, scoops, brushes, and a rotating removal system, were developed to remove specific material types. Personnel safety and material handling requirements were addressed throughout the project.

  5. Biodiesel Handling and Use Guide | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LISTStar Energy LLC Jump to:Greece:BajoBelpowerBiocar Jump to:BiodeselEslaHandling and

  6. Clean Air Bill 

    E-Print Network [OSTI]

    Her Majesty's Stationary Office

    1955-01-01

    The object of this Bill is to implement the principal recommendations in the Report of the Committee on Air Pollution

  7. on man, nature & air pollution

    E-Print Network [OSTI]

    Finlayson-Pitts, Barbara J

    2008-01-01

    on man, nature & air pollution About three decades ago, itand episodes of air pollution the following summer. Wetthe increase in air pollution. This hypothesis generated

  8. Termination unit

    DOE Patents [OSTI]

    Traeholt, Chresten [Frederiksberg, DK; Willen, Dag [Klagshamn, SE; Roden, Mark [Newnan, GA; Tolbert, Jerry C [Carrollton, GA; Lindsay, David [Carrollton, GA; Fisher, Paul W [Heiskell, TN; Nielsen, Carsten Thidemann [Jaegerspris, DK

    2014-01-07

    This invention relates to a termination unit comprising an end-section of a cable. The end section of the cable defines a central longitudinal axis and comprising end-parts of N electrical phases, an end-part of a neutral conductor and a surrounding thermally insulation envelope adapted to comprising a cooling fluid. The end-parts of the N electrical phases and the end-part of the neutral conductor each comprising at least one electrical conductor and being arranged in the cable concentrically around a core former with a phase 1 located relatively innermost, and phase N relatively outermost in the cable, phase N being surrounded by the neutral conductor, electrical insulation being arrange between neighboring electrical phases and between phase N and the neutral conductor, and wherein the end-parts of the neutral conductor and the electrical phases each comprise a contacting surface electrically connected to at least one branch current lead to provide an electrical connection: The contacting surfaces each having a longitudinal extension, and being located sequentially along the longitudinal extension of the end-section of the cable. The branch current leads being individually insulated from said thermally insulation envelope by individual electrical insulators.

  9. Small Units inside Large Units 8.1 Experimental units bigger than observational units

    E-Print Network [OSTI]

    Bailey, R. A.

    Chapter 8 Small Units inside Large Units 8.1 Experimental units bigger than observational units 8, but it is individual people that are measured. In general, suppose that there are m experimental units, each of which consists of k observational units, and that there are t treatments, each of which is applied

  10. Commercial Buildings High Performance Rooftop Unit Challenge

    SciTech Connect (OSTI)

    2011-12-16

    The U.S. Department of Energy (DOE) and the Commercial Building Energy Alliances (CBEAs) are releasing a new design specification for high performance rooftop air conditioning units (RTUs). Manufacturers who develop RTUs based on this new specification will find strong interest from the commercial sector due to the energy and financial savings.

  11. Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference

    E-Print Network [OSTI]

    Wechsler, Risa H.

    Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference Department: Chemical permit regulations are designed to track, record, and control air pollutants belonging to several on chemical classifications. This reference outlines major categories of air pollutants found at SLAC

  12. Dissemination and Presentation of High Resolution Air Pollution Data from Mobile Sensor Nodes

    E-Print Network [OSTI]

    Koutsoukos, Xenofon D.

    Dissemination and Presentation of High Resolution Air Pollution Data from Mobile Sensor Nodes method of air pollution monitoring in the United States includes sampling airborne pollutants hourly. Since pollution is highly location de- pendent, there is insufficient data to accurately evaluate air

  13. 2180, Page 1 International Refrigeration and Air Conditioning Conference at Purdue, July 14-17, 2014

    E-Print Network [OSTI]

    2180, Page 1 15th International Refrigeration and Air Conditioning Conference at Purdue, July 14 in Yashar and Lee (2013); they optimized the evaporator circuitry for a rooftop air- conditioning (RTU) unit;2180, Page 2 15th International Refrigeration and Air Conditioning Conference at Purdue, July 14-17, 2014

  14. Laboratory Performance Testing of Residential Window Air Conditioners

    SciTech Connect (OSTI)

    Winkler, J.; Booten, C.; Christensen, D.; Tomerlin, J.

    2013-03-01

    Window air conditioners are the dominant cooling product for residences, in terms of annual unit sales. They are inexpensive, portable and can be installed by the owner. For this reason, they are an attractive solution for supplemental cooling, for retrofitting air conditioning into a home which lacks ductwork, and for renters. Window air conditioners for sale in the United States are required to meet very modest minimum efficiency standards. Four window air conditioners' performance were tested in the Advanced HVAC Systems Laboratory on NREL's campus in Golden, CO. In order to separate and study the refrigerant system's performance, the unit's internal leakage pathways, the unit's fanforced ventilation, and the leakage around the unit resulting from installation in a window, a series of tests were devised that focused on each aspect of the unit's performance. These tests were designed to develop a detailed performance map to determine whole-house performance in different climates. Even though the test regimen deviated thoroughly from the industry-standard ratings test, the results permit simple calculation of an estimated rating for both capacity and efficiency that would result from a standard ratings test. Using this calculation method, it was found that the three new air conditioners' measured performance was consistent with their ratings. This method also permits calculation of equivalent SEER for the test articles. Performance datasets were developed across a broad range of indoor and outdoor operating conditions, and used them to generate performance maps.

  15. Advanced Aerodynamic Devices to Improve the Performance, Economics, Handling, and Safety of Heavy Vehicles

    SciTech Connect (OSTI)

    Robert J. Englar

    2001-05-14

    Research is being conducted at the Georgia Tech Research Institute (GTRI) to develop advanced aerodynamic devices to improve the performance, economics, stability, handling and safety of operation of Heavy Vehicles by using previously-developed and flight-tested pneumatic (blown) aircraft technology. Recent wind-tunnel investigations of a generic Heavy Vehicle model with blowing slots on both the leading and trailing edges of the trailer have been conducted under contract to the DOE Office of Heavy Vehicle Technologies. These experimental results show overall aerodynamic drag reductions on the Pneumatic Heavy Vehicle of 50% using only 1 psig blowing pressure in the plenums, and over 80% drag reductions if additional blowing air were available. Additionally, an increase in drag force for braking was confirmed by blowing different slots. Lift coefficient was increased for rolling resistance reduction by blowing only the top slot, while downforce was produced for traction increase by blowing only the bottom. Also, side force and yawing moment were generated on either side of the vehicle, and directional stability was restored by blowing the appropriate side slot. These experimental results and the predicted full-scale payoffs are presented in this paper, as is a discussion of additional applications to conventional commercial autos, buses, motor homes, and Sport Utility Vehicles.

  16. Performance Assessment for the Idaho National Laboratory Remote-Handled Low-Level Waste Disposal Facility

    SciTech Connect (OSTI)

    Annette L. Schafer; A. Jeffrey Sondrup; Arthur S. Rood

    2012-05-01

    This performance assessment for the Remote-Handled Low-Level Radioactive Waste Disposal Facility at the Idaho National Laboratory documents the projected radiological dose impacts associated with the disposal of low-level radioactive waste at the facility. This assessment evaluates compliance with the applicable radiological criteria of the U.S. Department of Energy and the U.S. Environmental Protection Agency for protection of the public and the environment. The calculations involve modeling transport of radionuclides from buried waste to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses are calculated for both offsite receptors and individuals who inadvertently intrude into the waste after site closure. The results of the calculations are used to evaluate the future performance of the low-level radioactive waste disposal facility and to provide input for establishment of waste acceptance criteria. In addition, one-factor-at-a-time, Monte Carlo, and rank correlation analyses are included for sensitivity and uncertainty analysis. The comparison of the performance assessment results to the applicable performance objectives provides reasonable expectation that the performance objectives will be met

  17. Air to Air Communication Protocol Arjan Durresi1

    E-Print Network [OSTI]

    Jain, Raj

    1 Air to Air Communication Protocol Arjan Durresi1 , Vamsi Paruchuri1 , Leonard Barolli2 and Raj. Louis, MO 63130, USA 314-935-4963, jain@cse.wustl.edu Abstract--We present Air to Air Communication (AAC........................................................2 3. AIR TO AIR COMMUNICATION..............................3 4. SIMULATIONS

  18. DEVELOPMENT OF AIR-TO-AIR HEAT PUMP SIMULATION PROGRAM WITH ADVANCED

    E-Print Network [OSTI]

    17, United States Code. ProQuest Information and Learning Company 300 North Zeeb Road P.O. Box 1346 Ann Arbor, MI 48106-1346 by ProQuest Information and Learning Company. #12;DEVELOPMENT OF AIR to write the acknowledgments. My family members are supportive all the way. My parents raised all of us

  19. Oil and Gas Air Heaters 

    E-Print Network [OSTI]

    Kou, G.; Wang, H.; Zhou, J.

    2006-01-01

    Most conventional air heaters adopt indirect heat transfer, which uses combustion gases to indirectly heat fresh air by heating surfaces to generate hot air used for material drying and dehumidification. We call them indirect air heaters. However...

  20. ORIGINAL ARTICLE Ambient Air Pollution

    E-Print Network [OSTI]

    Mulholland, James A.

    ORIGINAL ARTICLE Ambient Air Pollution and Cardiovascular Emergency Department Visits Kristi Busico ambient air pollutants and cardiovascular disease (CVD), the roles of the physicochemical components the relation between ambient air pollution and cardiovascular conditions using ambient air quality data

  1. Design & Engineering Services SPEAKMAN HYBRID ROOFTOP UNIT PERFORMANCE

    E-Print Network [OSTI]

    California at Davis, University of

    Design & Engineering Services SPEAKMAN HYBRID ROOFTOP UNIT PERFORMANCE: WESTERN COOLING CHALLENGE, and the National Renewable Energy Laboratory (NREL) conducted the physical laboratory tests at their facility for their contribution of the Air20 Quattro HCRS2500 hybrid rooftop unit used for evaluation, and is grateful to the US

  2. Design & Engineering Services AIRMAX HYBRID ROOFTOP UNIT PERFORMANCE: WESTERN

    E-Print Network [OSTI]

    California at Davis, University of

    Design & Engineering Services AIRMAX HYBRID ROOFTOP UNIT PERFORMANCE: WESTERN COOLING CHALLENGE. and the National Renewable Energy Laboratory (NREL) conducted the physical laboratory tests at their facility for their contribution of the Air20 Quattro HCRS2500 hybrid rooftop unit used for evaluation, and is grateful to the US

  3. The Cutting Edge of Modernity: Machine Tools in the United States and Germany 1930-1945

    E-Print Network [OSTI]

    Ristuccia, Cristiano A.; Tooze, J. Adam

    2004-06-16

    and that for December 1933.16 15 From 1930 the inventories also provided an increasing coverage on auxiliary metal-working plant equipment (heat treating, material handling, foundry equipment, finishing... into ovens), air compressors, oil extracting machines (from metal chips), parts washing machines, drying machines, pickling machines, tumbling barrels, sand blast equipment, spraying systems, portable welding outfits, portable tools (drills, grinders, power...

  4. Determining the Right Air Quality for Your Compressed Air System - Compressed Air Tip Sheet #5

    SciTech Connect (OSTI)

    2004-08-01

    BestPractices Program tip sheet discussing how to determine the right air quality for compressed air systems.

  5. Automated cassette-to-cassette substrate handling system

    DOE Patents [OSTI]

    Kraus, Joseph Arthur; Boyer, Jeremy James; Mack, Joseph; DeChellis, Michael; Koo, Michael

    2014-03-18

    An automated cassette-to-cassette substrate handling system includes a cassette storage module for storing a plurality of substrates in cassettes before and after processing. A substrate carrier storage module stores a plurality of substrate carriers. A substrate carrier loading/unloading module loads substrates from the cassette storage module onto the plurality of substrate carriers and unloads substrates from the plurality of substrate carriers to the cassette storage module. A transport mechanism transports the plurality of substrates between the cassette storage module and the plurality of substrate carriers and transports the plurality of substrate carriers between the substrate carrier loading/unloading module and a processing chamber. A vision system recognizes recesses in the plurality of substrate carriers corresponding to empty substrate positions in the substrate carrier. A processor receives data from the vision system and instructs the transport mechanism to transport substrates to positions on the substrate carrier in response to the received data.

  6. A Scintillator Purification Plant and Fluid Handling System for SNO+

    E-Print Network [OSTI]

    Ford, Richard J

    2015-01-01

    A large capacity purification plant and fluid handling system has been constructed for the SNO+ neutrino and double-beta decay experiment, located 6800 feet underground at SNOLAB, Canada. SNO+ is a refurbishment of the SNO detector to fill the acrylic vessel with liquid scintillator based on Linear Alkylbenzene (LAB) and 2 g/L PPO, and also has a phase to load natural tellurium into the scintillator for a double-beta decay experiment with 130Te. The plant includes processes multi-stage dual-stream distillation, column water extraction, steam stripping, and functionalized silica gel adsorption columns. The plant also includes systems for preparing the scintillator with PPO and metal-loading the scintillator for double-beta decay exposure. We review the basis of design, the purification principles, specifications for the plant, and the construction and installations. The construction and commissioning status is updated.

  7. A Scintillator Purification Plant and Fluid Handling System for SNO+

    E-Print Network [OSTI]

    Richard J. Ford; for the SNO+ Collaboration

    2015-06-29

    A large capacity purification plant and fluid handling system has been constructed for the SNO+ neutrino and double-beta decay experiment, located 6800 feet underground at SNOLAB, Canada. SNO+ is a refurbishment of the SNO detector to fill the acrylic vessel with liquid scintillator based on Linear Alkylbenzene (LAB) and 2 g/L PPO, and also has a phase to load natural tellurium into the scintillator for a double-beta decay experiment with 130Te. The plant includes processes multi-stage dual-stream distillation, column water extraction, steam stripping, and functionalized silica gel adsorption columns. The plant also includes systems for preparing the scintillator with PPO and metal-loading the scintillator for double-beta decay exposure. We review the basis of design, the purification principles, specifications for the plant, and the construction and installations. The construction and commissioning status is updated.

  8. Defense Remote Handled Transuranic Waste Cost/Schedule Optimization Study

    SciTech Connect (OSTI)

    Pierce, G.D. . Joint Integration Office); Beaulieu, D.H. ); Wolaver, R.W.; Carson, P.H. Corp., Boulder, CO )

    1986-11-01

    The purpose of this study is to provide the DOE information with which it can establish the most efficient program for the long management and disposal, in the Waste Isolation Pilot Plant (WIPP), of remote handled (RH) transuranic (TRU) waste. To fulfill this purpose, a comprehensive review of waste characteristics, existing and projected waste inventories, processing and transportation options, and WIPP requirements was made. Cost differences between waste management alternatives were analyzed and compared to an established baseline. The result of this study is an information package that DOE can use as the basis for policy decisions. As part of this study, a comprehensive list of alternatives for each element of the baseline was developed and reviewed with the sites. The principle conclusions of the study follow. A single processing facility for RH TRU waste is both necessary and sufficient. The RH TRU processing facility should be located at Oak Ridge National Laboratory (ORNL). Shielding of RH TRU to contact handled levels is not an economic alternative in general, but is an acceptable alternative for specific waste streams. Compaction is only cost effective at the ORNL processing facility, with a possible exception at Hanford for small compaction of paint cans of newly generated glovebox waste. It is more cost effective to ship certified waste to WIPP in 55-gal drums than in canisters, assuming a suitable drum cask becomes available. Some waste forms cannot be packaged in drums, a canister/shielded cask capability is also required. To achieve the desired disposal rate, the ORNL processing facility must be operational by 1996. Implementing the conclusions of this study can save approximately $110 million, compared to the baseline, in facility, transportation, and interim storage costs through the year 2013. 10 figs., 28 tabs.

  9. United Nations Programme on

    E-Print Network [OSTI]

    Schrijver, Karel

    United Nations Programme on Space Applications UNITED NATIONS UNITED NATIONS OFFICE FOR OUTER SPACE, Sputnik 1. Soon after that event, the Member States of the United Nations declared that space should and natural resources management. At the first United Nations Conference on the Exploration and Peaceful Uses

  10. Economizer control assembly for regulating the volume flow of outdoor ambient air

    SciTech Connect (OSTI)

    Michaels, D.D. Jr.

    1984-10-23

    An economizer assembly is disclosed wherein a sliding door is utilized for covering an outdoor ambient air opening allowing outdoor ambient air flow into a space to be conditioned. A motor shaft arrangement connected via a rotating drive rod is utilized to slidably displace the door to any position necessary to effectively regulate air flow. The utilization of this economizer control arrangement with a rooftop type air conditioning unit is further disclosed.

  11. ENHANCEMENT OF ENVIRONMENTAL SAMPLING THROUGH AN IMPROVED AIR MONITORING TECHNIQUE

    SciTech Connect (OSTI)

    Hanks, D.

    2010-06-07

    Environmental sampling (ES) is a key component of International Atomic Energy Agency (IAEA) safeguarding approaches throughout the world. Performance of ES (e.g. air, water, vegetation, sediments, soil and biota) supports the IAEAs mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a State and has been available since the introduction of safeguards strengthening measures approved by the IAEA Board of Governors (1992-1997). A recent step-change improvement in the gathering and analysis of air samples at uranium/plutonium bulk handling facilities is an important addition to the international nuclear safeguards inspector's toolkit. Utilizing commonly used equipment throughout the IAEA network of analytical laboratories for particle analysis, researchers are developing the next generation of ES equipment for air grab and constant samples. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) silicon substrate has been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. The new collection equipment will allow IAEA nuclear safeguards inspectors to develop enhanced safeguarding approaches for complicated facilities. This paper will explore the use of air monitoring to establish a baseline environmental signature of a particular facility that could be used for comparison of consistencies in declared operations. The implementation of air monitoring will be contrasted against the use of smear ES when used during unannounced inspections, design information verification, limited frequency unannounced access, and complementary access visits at bulk handling facilities. Technical aspects of the air monitoring device and the analysis of its environmental samples will demonstrate the essential parameters required for successful application of the system.

  12. High Level Waste Remote Handling Equipment in the Melter Cave Support Handling System at the Hanford Waste Treatment Plant

    SciTech Connect (OSTI)

    Bardal, M.A. [PaR Systems, Inc., Shoreview, MN (United States); Darwen, N.J. [Bechtel National, Inc., Richland, WA (United States)

    2008-07-01

    Cold war plutonium production led to extensive amounts of radioactive waste stored in tanks at the Department of Energy's (DOE) Hanford site. Bechtel National, Inc. is building the largest nuclear Waste Treatment Plant in the world located at the Department of Energy's Hanford site to immobilize the millions of gallons of radioactive waste. The site comprises five main facilities; Pretreatment, High Level Waste vitrification, Low Active Waste vitrification, an Analytical Lab and the Balance of Facilities. The pretreatment facilities will separate the high and low level waste. The high level waste will then proceed to the HLW facility for vitrification. Vitrification is a process of utilizing a melter to mix molten glass with radioactive waste to form a stable product for storage. The melter cave is designated as the High Level Waste Melter Cave Support Handling System (HSH). There are several key processes that occur in the HSH cell that are necessary for vitrification and include: feed preparation, mixing, pouring, cooling and all maintenance and repair of the process equipment. Due to the cell's high level radiation, remote handling equipment provided by PaR Systems, Inc. is required to install and remove all equipment in the HSH cell. The remote handling crane is composed of a bridge and trolley. The trolley supports a telescoping tube set that rigidly deploys a TR 4350 manipulator arm with seven degrees of freedom. A rotating, extending, and retracting slewing hoist is mounted to the bottom of the trolley and is centered about the telescoping tube set. Both the manipulator and slewer are unique to this cell. The slewer can reach into corners and the manipulator's cross pivoting wrist provides better operational dexterity and camera viewing angles at the end of the arm. Since the crane functions will be operated remotely, the entire cell and crane have been modeled with 3-D software. Model simulations have been used to confirm operational and maintenance functional and timing studies throughout the design process. Since no humans can go in or out of the cell, there are several recovery options that have been designed into the system including jack-down wheels for the bridge and trolley, recovery drums for the manipulator hoist, and a wire rope cable cutter for the slewer jib hoist. If the entire crane fails in cell, the large diameter cable reel that provides power, signal, and control to the crane can be used to retrieve the crane from the cell into the crane maintenance area. (authors)

  13. Molten salt coal gasification process development unit. Phase 1. Volume 2. Commercial plant study. Final report

    SciTech Connect (OSTI)

    Kohl, Arthur L.

    1980-05-01

    This report summarizes the results of a test program conducted on the Molten Salt Coal Gasification Process, which included the design, construction, and operation of a Process Development Unit (PDU). This process, coal is gasified by contacting it with air in a turbulent pool of molten sodium carbonate. Sulfur and ash are retained in the melt, and a small stream is continuously removed from the gasifier for regeneration of the salt. The process can handle a wide variety of feed materials, including highly caking coals, and produces a gas relatively free from tars and other impurities. The gasification step is carried out at approximately 1800/sup 0/F. The PDU was designed to process 1 ton per hour of coal at pressures up to 20 atm. It is a completely integrated facility including systems for feeding solids to the gasifier, regenerating sodium carbonate for reuse, and removing sulfur and ash in forms suitable for disposal. Five extended test runs were made. The observed product gas composition was quite close to that predicted on the basis of earlier small-scale tests and thermodynamic considerations. All plant systems were operated in an integrated manner. Test data and discussions regarding plant equipment and process performance are presented. The program also included a commercial plant study which showed the process to be attractive for use in a combined cycle, electric power plant. The report is presented in two volumes, Volume 1, PDU Operations, and Volume 2, Commercial Plant Study.

  14. China's international trade and air pollution in the United States

    E-Print Network [OSTI]

    2014-01-01

    be- tween production- and consumption-based emissions oftogether with the production- and consumption-based emis-in both production- and consumption-based emissions per

  15. UNITED STATES AIR FORCE LIEUTENANT COLONEL DAVID LEE WEIDE

    E-Print Network [OSTI]

    Maxwell, Bruce D.

    ), Schriever AFB, CO 10. Oct 05-May 07 Executive Officer, 50th Mission Support Group (AFSPC), Schriever AFB, CO

  16. United_CoolAir_Ex Parte Meeting Memo.pdf

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LIST OF APPLICABLEStatutoryin theNuclear Energy Research andofRod Beever

  17. Indoor Air Quality

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    In Focus For decades, teams of Berkeley Lab scientists have investigated the ways that indoor air quality affects human health-from cognitive ability to personal comfort...

  18. Personal continuous air monitor

    DOE Patents [OSTI]

    Morgan, Ronald G. (Los Alamos, NM); Salazar, Samuel A. (Albuquerque, NM)

    2000-01-01

    A personal continuous air monitor capable of giving immediate warning of the presence of radioactivity has a filter/detector head to be worn in the breathing zone of a user, containing a filter mounted adjacent to radiation detectors, and a preamplifier. The filter/detector head is connected to a belt pack to be worn at the waist or on the back of a user. The belt pack contains a signal processor, batteries, a multichannel analyzer, a logic circuit, and an alarm. An air pump also is provided in the belt pack for pulling air through the filter/detector head by way of an air tube.

  19. Solar Powered Radioactive Air Monitoring Stations

    SciTech Connect (OSTI)

    Barnett, J. M.; Bisping, Lynn E.; Gervais, Todd L.

    2013-10-30

    Environmental monitoring of ambient air for radioactive material is required as stipulated in the PNNL Site radioactive air license. Sampling ambient air at identified preferred locations could not be initially accomplished because utilities were not readily available. Therefore, solar powered environmental monitoring systems were considered as a possible option. PNNL purchased two 24-V DC solar powered environmental monitoring systems which consisted of solar panels, battery banks, and sampling units. During an approximate four month performance evaluation period, the solar stations operated satisfactorily at an on-site test location. They were subsequently relocated to their preferred locations in June 2012 where they continue to function adequately under the conditions found in Richland, Washington.

  20. Stirling engine with air working fluid

    DOE Patents [OSTI]

    Corey, John A. (North Troy, NY)

    1985-01-01

    A Stirling engine capable of utilizing air as a working fluid which includes a compact heat exchange module which includes heating tube units, regenerator and cooler positioned about the combustion chamber. This arrangement has the purpose and effect of allowing the construction of an efficient, high-speed, high power-density engine without the use of difficult to seal light gases as working fluids.

  1. Rating of Mixed Split Residential Air Conditioners 

    E-Print Network [OSTI]

    Domanski, P. A.

    1988-01-01

    require that manufac- turers derive cooling ratings for unitary systems by testing a sample of sufficient size to meet certain specified statistical confidence levels. For split unitary systems comprising an outdoor unit and an indoor coil assembly...(95), SEER, and recommended indoor volumetric flow rate of air, are publicly available. The procedure also assumee that the matched indoor section is available for inspection and evaluation of the indoor coil capacity and the indoor fan power...

  2. " Million Housing Units, Final...

    U.S. Energy Information Administration (EIA) Indexed Site

    2 Water Heating in U.S. Homes, by OwnerRenter Status, 2009" " Million Housing Units, Final" ,,,,"Housing Unit Type" ,,,,"Single-Family Units",,,,"Apartments in Buildings With"...

  3. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Forest and Range symposium dealing with this subject in the western United States, the papers presented address current ........................................................................................................................................ 1 Annosus Root Disease in Europe and the Southeastern United States: Occurrence, Research

  4. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Northeastern Forest Experiment Station research unit in New Hampshirein 1957, where he studied problemsof regenerationandthinning research unit at Warren, Pennsylvania, where he headed a program of research on problems related

  5. Unit 35 - Raster Storage

    E-Print Network [OSTI]

    Unit 35, CC in GIS; Peuquet, Donna

    1990-01-01

    in GIS - 1990 Page 8 Unit 35 - Raster Storage GIS to whichNCGIA Core Curriculum in GIS - 1990 Page 9 Unit 35 - RasterStorage UNIT 35 IMAGES NCGIA Core Curriculum in GIS - 1990

  6. Handling of Highly Radioactive Radiation Sources in a Hot Cell Using a Mechanically Driven Cell Crane - 13452

    SciTech Connect (OSTI)

    Klute, Stefan; Huber, Wolfgang-Bruno [Siempelkamp Nukleartechnik GmbH, Am Taubenfeld 25/1, 69123 Heidelberg (Germany)] [Siempelkamp Nukleartechnik GmbH, Am Taubenfeld 25/1, 69123 Heidelberg (Germany); Meyer, Franz [Nuclear Engineering Seibersdorf GmbH, 2444 Seibersdorf (Austria)] [Nuclear Engineering Seibersdorf GmbH, 2444 Seibersdorf (Austria)

    2013-07-01

    In 2010, Siempelkamp Nukleartechnik GmbH was awarded the contract for design and erection of a Hot Cell for handling and storage of highly radioactive radiation sources. This Hot Cell is part of a new hot cell laboratory, constructed for the NHZ (Neues Handhabungszentrum = New Handling Center) of the Nuclear Engineering Seibersdorf GmbH (NES). All incurring radioactive materials from Austria are collected in the NHZ, where they are safely conditioned and stored temporarily until their final storage. The main tasks of the NES include, apart from the collection, conditioning and storage of radioactive waste, also the reprocessing and the decontamination of facilities and laboratories originating from 45 years of research and development at the Seibersdorf site as well as the operation of the Hot Cell Laboratory [1]. The new Hot Cell Laboratory inside the NHZ consists of the following room areas: - One hot cell, placed in the center, for remote controlled, radiation protected handling of radioactive materials, including an integrated floor storage for the long-term temporary storage of highly radioactive radiation sources; - An anteroom for the loading and unloading of the hot cell; - One control room for the remote controlling of the hot cell equipment; - One floor storage, placed laterally to the hot cell, for burial, interim storage and removal of fissionable radioactive material in leak-proof packed units in 100 l drums. The specific design activity of the hot cell of 1.85 Pbq relating to 1-Me-Radiator including the integrated floor storage influences realization and design of the components used in the cell significantly. (authors)

  7. RESCHEDULED: Webinar on Material Handling Fuel Cells for Building Electric Peak Shaving Applications

    Broader source: Energy.gov [DOE]

    The Fuel Cell Technologies Office will present a live webinar entitled "Material Handling Fuel Cells for Building Electric Peak Shaving Applications".

  8. Remote-Handled Low-Level Waste (RHLLW) Disposal Project Code of Record

    SciTech Connect (OSTI)

    S.L. Austad, P.E.; L.E. Guillen, P.E.; C. W. McKnight, P.E.; D. S. Ferguson, P.E.

    2010-10-01

    The Remote-Handled Low-Level Waste Disposal Project addresses an anticipated shortfall in remote-handled LLW disposal capability following cessation of operations at the existing facility, which will continue until it is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of fiscal year 2015). Development of a new onsite disposal facility, the highest ranked alternative, will provide necessary remote handled LLW disposal capability and will ensure continuity of operations that generate remote-handled LLW. This report documents the Code of Record for design of a new LLW disposal capability.

  9. Abstract: Transactions and recoverable memories are pow-erful mechanisms for handling failures and manipulating

    E-Print Network [OSTI]

    Chen, Peter M.

    [Chen96]. Combined with an uninterruptible power supply, Rio provides persistent memory to applications]. Transactions are acclaimed widely as a powerful mechanism for handling failures. Transactions simplify pro

  10. Leads Tactical Air Control Party (TACP) and Air Support

    E-Print Network [OSTI]

    Stuart, Steven J.

    Air LiAison officer Leads Tactical Air Control Party (TACP) and Air Support Operations Center (ASOC) operations. Provides Command and Control, and Execution of Air, Space, and Cyber power. Primary advisor and advocate to the Ground Force Commander ensuring effective Air, Space, and Cyber power integration with US

  11. Appendix F. Air Permits Appendix F. Air Permits F-3

    E-Print Network [OSTI]

    Pennycook, Steve

    Appendix F. Air Permits #12;#12;Appendix F. Air Permits F-3 Table F.1. Air Permits at the Y-12 Chemical Process Operation 01-0020-21 554701 Air Bearing Operation 01-0020-05 554701 Special Processing Purification Facility #12;Oak Ridge Reservation F-4 Appendix F. Air Permits Table F.2. Oak Ridge National

  12. Appendix E. Air Permits Appendix E. Air Permits E-3

    E-Print Network [OSTI]

    Pennycook, Steve

    Appendix E. Air Permits #12;#12;Appendix E. Air Permits E-3 Table E.1. Air permits at the Y-12 Chemical Process Operation 01-0020-21 554701 Air Bearing Operation 01-0020-05 554701 Special Processing Operation 01-0020-68 554701 Disassembly and Storage Operation #12;Oak Ridge Reservation E-4 Appendix E. Air

  13. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Research Station General assigned to the Station's research unit studying the regeneration of California forests

  14. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture MIX: A Computer Program to Evaluate Forest Service, a research entomologist, is in charge of the unit developing improved technology for integrated management

  15. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Research Station General Programs: A Review of Cognitive and Behavioral Studies Introduction Recent wildfires in the Western United

  16. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Forest and Range to the Chaparral Prescribed Fire Research Unit, headquartered at Riverside, California. Publisher: Pacific

  17. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Research Station General is a Research Ecologist at the Station's Timber Management/Wildlife Habitat Interactions Unit, Redwood Sciences

  18. United States of Agriculture

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Research Station General scientist with the Station's Wildland Recreation and Urban Cultures Research Unit, 4955 Canyon Crest Drive

  19. United States Department of

    E-Print Network [OSTI]

    Kurapov, Alexander

    A United States Department of Agriculture Forest Service Pacific Northwest Research Station General, land management, carbon sequestration, carbon markets, United States. #12;ii Executive Summary

  20. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Intermountain Research Station General acrossthe United States provide estimates of the amount of erosion reductionon forest roadsfrom

  1. United States Department of

    E-Print Network [OSTI]

    94701 United States Department of Agriculture Forest Service Pacific Southwest Forest and Range of California, Berkeley, and a cooperator with the Research Unit. #12;Acknowledgments We especially acknowledge

  2. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Forest and Range to the Station's chaparral and related ecosystems research unit, with headquarters at Riverside, California. He

  3. United States Department of

    E-Print Network [OSTI]

    United States Department of California Oaks: A Bibliography Agriculture Forest Service Pacific forester in the Station's Forest Regeneration Research Unit, at Redding, California. He holds bachelor

  4. United States Department of

    E-Print Network [OSTI]

    Wang, Changlu

    United States Department of Agriculture Rural Business- Cooperative Service Research Report 157, concentration, globalization, agency theory Cooperatives in a Changing Global Food System United States

  5. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Research Station General is a supervisory research entomologist in the Station's Regeneration Insect Research Unit in Berkeley. W. WAYNE

  6. History of Air Conditioning

    Office of Energy Efficiency and Renewable Energy (EERE)

    We take it for granted but what would life be like without the air conditioner? Once considered a luxury, this invention is now an essential, allowing us to cool everything from homes, businesses, businesses, data centers, laboratories and other buildings vital to our daily lives. Explore this timeline to learn some of the key dates in the history of air conditioning.

  7. Recirculating electric air filter

    DOE Patents [OSTI]

    Bergman, W.

    1985-01-09

    An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  8. Compressed Air System Optimization 

    E-Print Network [OSTI]

    Aegerter, R.

    1999-01-01

    Several years ago I went to a gas station and noticed that my car's tires were low on air. I saw the gas station had an air compressor, but it cost a quarter to use the compressor. I paid my quarter and used the compressor. I realized...

  9. Recirculating electric air filter

    DOE Patents [OSTI]

    Bergman, Werner (Pleasanton, CA)

    1986-01-01

    An electric air filter cartridge has a cylindrical inner high voltage eleode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  10. Air and water cooled modulator

    DOE Patents [OSTI]

    Birx, Daniel L. (Oakley, CA); Arnold, Phillip A. (Livermore, CA); Ball, Don G. (Livermore, CA); Cook, Edward G. (Livermore, CA)

    1995-01-01

    A compact high power magnetic compression apparatus and method for delivering high voltage pulses of short duration at a high repetition rate and high peak power output which does not require the use of environmentally unacceptable fluids such as chlorofluorocarbons either as a dielectric or as a coolant, and which discharges very little waste heat into the surrounding air. A first magnetic switch has cooling channels formed therethrough to facilitate the removal of excess heat. The first magnetic switch is mounted on a printed circuit board. A pulse transformer comprised of a plurality of discrete electrically insulated and magnetically coupled units is also mounted on said printed board and is electrically coupled to the first magnetic switch. The pulse transformer also has cooling means attached thereto for removing heat from the pulse transformer. A second magnetic switch also having cooling means for removing excess heat is electrically coupled to the pulse transformer. Thus, the present invention is able to provide high voltage pulses of short duration at a high repetition rate and high peak power output without the use of environmentally unacceptable fluids and without discharging significant waste heat into the surrounding air.

  11. Air and water cooled modulator

    DOE Patents [OSTI]

    Birx, D.L.; Arnold, P.A.; Ball, D.G.; Cook, E.G.

    1995-09-05

    A compact high power magnetic compression apparatus and method are disclosed for delivering high voltage pulses of short duration at a high repetition rate and high peak power output which does not require the use of environmentally unacceptable fluids such as chlorofluorocarbons either as a dielectric or as a coolant, and which discharges very little waste heat into the surrounding air. A first magnetic switch has cooling channels formed therethrough to facilitate the removal of excess heat. The first magnetic switch is mounted on a printed circuit board. A pulse transformer comprised of a plurality of discrete electrically insulated and magnetically coupled units is also mounted on said printed board and is electrically coupled to the first magnetic switch. The pulse transformer also has cooling means attached thereto for removing heat from the pulse transformer. A second magnetic switch also having cooling means for removing excess heat is electrically coupled to the pulse transformer. Thus, the present invention is able to provide high voltage pulses of short duration at a high repetition rate and high peak power output without the use of environmentally unacceptable fluids and without discharging significant waste heat into the surrounding air. 9 figs.

  12. Self-actuating mechanical grapple for lifting and handling objects

    DOE Patents [OSTI]

    Hovis, Gregory L. (North Augusta, SC); Etheredge, Jr., Carl T. (Tuscaloosa, AL)

    2001-01-01

    A self-actuating mechanical grapple for lifting and handling an object includes a support housing with upper and lower portions and defining an internal recess. The lower portion of the housing includes a bottom opening which communicates with the recess. Preferably, two or three grapple jaws are provided, the first end portions of which are connected to the housing and the second end portions thereof remain free for engaging an object. The grapple jaws are pivotable between open and closed positions. An actuator member is slidably positioned in the recess for opening and closing the jaws, and includes a cam portion in operative engagement with the first end portions of the jaws in a manner to pivot the jaws when the actuator member moves axially relative to the housing. The actuator member includes a rotatable member with at least one contact member. A locking member or logic ring includes grooves defining open and closed positions of the jaws and is fixedly mounted to the internal surface of the housing and cooperates with the rotatable member. A plunger member is axially movable in the housing for contacting an object and includes at least one stud member for immovably engaging the contact member.

  13. A New Air Cerenkov Array at the South Pole

    E-Print Network [OSTI]

    Delaware, University of

    A New Air­ Ÿ Cerenkov Array at the South Pole J.E. Dickinson a J.R. Gill a S.P. Hart b;a G.C. Hill a a University of Leeds, Leeds LS2 9JT, United Kingdom b Amundsen­Scott South Pole Station, Antarctica c array of air­ Ÿ Cerenkov radiation detectors estab­ lished at the South Pole. VULCAN operates

  14. Air service to small communities-directions for the future : final report of the Workshop on Low/Medium Density Air Transportation

    E-Print Network [OSTI]

    Vittek, Joseph F.

    1974-01-01

    Introduction: In the decade between 1962 and 1972, certificated air service was deleted at about 250 points in the United States. In some of these cases, the service was no longer needed because of improved highway access ...

  15. An Innovative Approach for Data Collection and Handling to Enable Advancements in Micro Air Vehicle Persistent Surveillance 

    E-Print Network [OSTI]

    Goodnight, Ryan David

    2010-10-12

    as 50% - 62% of the total system mass.12,13 These considerations have led most MAV design teams to the conclusion that small, lightweight electric motors combined with micro-propellers are currently the ideal solution. Until recently, when rapid... is extremely susceptible to small variations in mass, are typically expected to be able to devote 12%-15% of the final system mass to a payload.12,13 With a target overall mass of 90 grams, this does not leave much room for the data acquisition hardware...

  16. Project Execution Plan for the Remote Handled Low-Level Waste Disposal Project

    SciTech Connect (OSTI)

    Danny Anderson

    2014-07-01

    As part of ongoing cleanup activities at the Idaho National Laboratory (INL), closure of the Radioactive Waste Management Complex (RWMC) is proceeding under the Comprehensive Environmental Response, Compensation, and Liability Act (42 USC 9601 et seq. 1980). INL-generated radioactive waste has been disposed of at RWMC since 1952. The Subsurface Disposal Area (SDA) at RWMC accepted the bulk of INL’s contact and remote-handled low-level waste (LLW) for disposal. Disposal of contact-handled LLW and remote-handled LLW ion-exchange resins from the Advanced Test Reactor in the open pit of the SDA ceased September 30, 2008. Disposal of remote-handled LLW in concrete disposal vaults at RWMC will continue until the facility is full or until it must be closed in preparation for final remediation of the SDA (approximately at the end of fiscal year FY 2017). The continuing nuclear mission of INL, associated ongoing and planned operations, and Naval spent fuel activities at the Naval Reactors Facility (NRF) require continued capability to appropriately dispose of contact and remote handled LLW. A programmatic analysis of disposal alternatives for contact and remote-handled LLW generated at INL was conducted by the INL contractor in Fiscal Year 2006; subsequent evaluations were completed in Fiscal Year 2007. The result of these analyses was a recommendation to the Department of Energy (DOE) that all contact-handled LLW generated after September 30, 2008, be disposed offsite, and that DOE proceed with a capital project to establish replacement remote-handled LLW disposal capability. An analysis of the alternatives for providing replacement remote-handled LLW disposal capability has been performed to support Critical Decision-1. The highest ranked alternative to provide this required capability has been determined to be the development of a new onsite remote-handled LLW disposal facility to replace the existing remote-handled LLW disposal vaults at the SDA. Several offsite DOE and commercial disposal options exist for contact-handled LLW; however, offsite disposal options are either not currently available (i.e., commercial disposal facilities), practical, or cost-effective for all remote-handled LLW streams generated at INL. Offsite disposal of all INL and tenant-generated remote-handled waste is further complicated by issues associated with transporting highly radioactive waste in commerce; and infrastructure and processing changes at the generating facilities, specifically NRF, that would be required to support offsite disposal. The INL Remote-Handled LLW Disposal Project will develop a new remote handled LLW disposal facility to meet mission-critical, remote-handled LLW disposal needs. A formal DOE decision to proceed with the project has been made in accordance with the requirements of National Environmental Policy Act (42 USC§ 4321 et seq.). Remote-handled LLW is generated from nuclear programs conducted at INL, including spent nuclear fuel handling and operations at NRF and operations at the Advanced Test Reactor. Remote-handled LLW also will be generated by new INL programs and from segregation and treatment (as necessary) of remote handled scrap and waste currently stored in the Radioactive Scrap and Waste Facility at the Materials and Fuels Complex.

  17. High efficiency novel window air conditioner

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Bansal, Pradeep

    2015-07-24

    This paper presents the technical development of a high efficiency window air conditioner. In order to achieve higher energy efficiency ratio (EER), the original capacity of the R410A unit was downgraded by replacing the original compressor with a lower capacity but higher EER compressor, while all heat exchangers and the chassis from the original unit were retained. The other subsequent major modifications included – the AC fan motor being replaced with a brushless high efficiency electronically commuted motor (ECM) motor, the capillary tube being replaced with a needle valve to better control the refrigerant flow and refrigerant set points, andmore »R410A being replaced with drop-in environmentally friendly binary mixture of R32 (85% molar concentration)/R125 (15% molar concentration). All these modifications resulted in significant EER enhancement of the modified unit.« less

  18. High efficiency novel window air conditioner

    SciTech Connect (OSTI)

    Bansal, Pradeep

    2015-07-24

    This paper presents the technical development of a high efficiency window air conditioner. In order to achieve higher energy efficiency ratio (EER), the original capacity of the R410A unit was downgraded by replacing the original compressor with a lower capacity but higher EER compressor, while all heat exchangers and the chassis from the original unit were retained. The other subsequent major modifications included – the AC fan motor being replaced with a brushless high efficiency electronically commuted motor (ECM) motor, the capillary tube being replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and R410A being replaced with drop-in environmentally friendly binary mixture of R32 (85% molar concentration)/R125 (15% molar concentration). All these modifications resulted in significant EER enhancement of the modified unit.

  19. 2. Unit Operation Dynamic simulation Unit operation

    E-Print Network [OSTI]

    Hong, Deog Ki

    flow heat exchanger . 2.3 Piping equipment Mixer, tee, pipe, gas pipe, valve, relief valve . 2 specification . 2.2 Heat transfer equipment Air cooler, cooler/heater, heat exchanger, fired heater LNG multi

  20. Air Resources: Prevention and Control of Air Contamination and...

    Broader source: Energy.gov (indexed) [DOE]

    limits and permitting and operational requirements for facilities that may contribute to air emissions. General air quality standards and standards for specific contaminants are...

  1. Abatement of Air Pollution: Prohibition of Air Pollution (Connecticut...

    Broader source: Energy.gov (indexed) [DOE]

    All air pollution not otherwise covered by these regulations is prohibited. Stationary sources which cause air pollution must be operated in accordance with all applicable...

  2. Abatement of Air Pollution: Hazardous Air Pollutants (Connecticut...

    Broader source: Energy.gov (indexed) [DOE]

    allowable stack concentrations and hazard limiting values for the emission of hazardous air pollutants. The regulations also discuss sampling procedures for hazardous air...

  3. Air Pollution Control Regulations: No. 7 - Emission of Air Contaminant...

    Broader source: Energy.gov (indexed) [DOE]

    with the enjoyment of life and property. The criteria for determining compliance is listed in the regulations, and is based on other air pollution and ambient air standards...

  4. Air ejector augmented compressed air energy storage system

    DOE Patents [OSTI]

    Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

    1980-01-01

    Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air pressure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

  5. Renewables and air quality

    SciTech Connect (OSTI)

    Wooley, D.R.

    2000-08-01

    The US heavy reliance on fossil fuels is a central obstacle to improving air quality and preventing catastrophic climate change. To solve this problem will require a combination of financial incentives and market rules that strongly encourage development of renewable energy resources to meet electric power demand. One promising policy option is to allow renewable energy resources to directly participate in air pollution emission trading mechanisms. Currently, the clean air benefits of renewable energy generally go unrecognized by regulators, under-appreciated by consumers and uncompensated by markets. Renewable energy is a key clean air alternative to conventional electricity generation, and the development of renewables could be stimulated by changes to the Clean Air Act's emissions trading programs. As Congress revisits clean air issues over the next several years, renewable energy representatives could push for statutory changes that reward the renewable energy industry for the air quality benefits it provides. By also becoming involved in key US Environmental Protection Agency (EPA) and state rule-making cases, the renewables industry could influence the structure of emissions trading programs and strengthen one of the most persuasive arguments for wind, solar and biomass energy development.

  6. Air Distribution Retrofit Strategies for Affordable Housing

    SciTech Connect (OSTI)

    Dentz, J.; Conlin, F.; Holloway, P.; Podorson, D.; Varshney, K.

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

  7. Lead Safety Awareness This Bulletin provides information on the safe handling of lead

    E-Print Network [OSTI]

    Lead Safety Awareness PURPOSE This Bulletin provides information on the safe handling of lead and lead compounds during use and storage. Improper handling of lead and lead compounds may impact operations at Department of Energy (DOE) facilities. BACKGROUND Lead is found in batteries, pipes, solder

  8. HANDLING," PACKAGING," TRANSPORTA-TION AND STORAGE OF ALSEP ARRAY E

    E-Print Network [OSTI]

    Rathbun, Julie A.

    HANDLING," PACKAGING," TRANSPORTA- TION AND STORAGE OF ALSEP ARRAY E FLIGHT HARDWARE AND SUPPORT related to preservation, packaging, handling, storing and shipping· Prepared by: {JJ. ../. -~, W. J. Lavin, Packaging, Transportation and Storage of ALSEP Array E Flight Hardware and Support Equipment TABLE

  9. Preliminary Hazard Analysis for the Remote-Handled Low-Level Waste Disposal Facility

    SciTech Connect (OSTI)

    Lisa Harvego; Mike Lehto

    2010-02-01

    The need for remote handled low level waste (LLW) disposal capability has been identified. A new onsite, remote-handled LLW disposal facility has been identified as the highest ranked alternative for providing continued, uninterrupted remote-handled LLW disposal capability for remote-handled LLW that is generated as part of the nuclear mission of the Idaho National Laboratory and from spent nuclear fuel processing activities at the Naval Reactors Facility. Historically, this type of waste has been disposed of at the Radioactive Waste Management Complex. Disposal of remote-handled LLW in concrete disposal vaults at the Radioactive Waste Management Complex will continue until the facility is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). This document supports the conceptual design for the proposed remote-handled LLW disposal facility by providing an initial nuclear facility hazard categorization and by identifying potential hazards for processes associated with onsite handling and disposal of remote-handled LLW.

  10. Preliminary Hazard Analysis for the Remote-Handled Low-Level Waste Disposal Project

    SciTech Connect (OSTI)

    Lisa Harvego; Mike Lehto

    2010-10-01

    The need for remote handled low level waste (LLW) disposal capability has been identified. A new onsite, remote-handled LLW disposal facility has been identified as the highest ranked alternative for providing continued, uninterrupted remote-handled LLW disposal capability for remote-handled LLW that is generated as part of the nuclear mission of the Idaho National Laboratory and from spent nuclear fuel processing activities at the Naval Reactors Facility. Historically, this type of waste has been disposed of at the Radioactive Waste Management Complex. Disposal of remote-handled LLW in concrete disposal vaults at the Radioactive Waste Management Complex will continue until the facility is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). This document supports the conceptual design for the proposed remote-handled LLW disposal facility by providing an initial nuclear facility hazard categorization and by identifying potential hazards for processes associated with onsite handling and disposal of remote-handled LLW.

  11. Preliminary Hazard Analysis for the Remote-Handled Low-Level Waste Disposal Facility

    SciTech Connect (OSTI)

    Lisa Harvego; Mike Lehto

    2010-05-01

    The need for remote handled low level waste (LLW) disposal capability has been identified. A new onsite, remote-handled LLW disposal facility has been identified as the highest ranked alternative for providing continued, uninterrupted remote-handled LLW disposal capability for remote-handled LLW that is generated as part of the nuclear mission of the Idaho National Laboratory and from spent nuclear fuel processing activities at the Naval Reactors Facility. Historically, this type of waste has been disposed of at the Radioactive Waste Management Complex. Disposal of remote-handled LLW in concrete disposal vaults at the Radioactive Waste Management Complex will continue until the facility is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). This document supports the conceptual design for the proposed remote-handled LLW disposal facility by providing an initial nuclear facility hazard categorization and by identifying potential hazards for processes associated with onsite handling and disposal of remote-handled LLW.

  12. Multi-Cue Pedestrian Classification With Partial Occlusion Handling Markus Enzweiler1

    E-Print Network [OSTI]

    Gavrila, Dariu M.

    Multi-Cue Pedestrian Classification With Partial Occlusion Handling Markus Enzweiler1 Angela for pedestrian classification with partial occlusion handling. The framework involves a set of component sets, with both partially occluded and non-occluded pedestrians, we obtain significant performance

  13. Handling Churn in a DHT Sean Rhea, Dennis Geels, Timothy Roscoe, and John Kubiatowicz

    E-Print Network [OSTI]

    Kubiatowicz, John D.

    Handling Churn in a DHT Sean Rhea, Dennis Geels, Timothy Roscoe, and John Kubiatowicz University Berkeley, California 94720 #12;Handling Churn in a DHT Sean Rhea, Dennis Geels, Timothy Roscoe, and John,geels,kubitron}@cs.berkeley.edu, troscoe@intel-research.net December 2003 Abstract This paper addresses the problem of churn--the continu

  14. Real-Time Deferrable Load Control: Handling the Uncertainties of Renewable Generation

    E-Print Network [OSTI]

    Low, Steven H.

    Real-Time Deferrable Load Control: Handling the Uncertainties of Renewable Generation Lingwen Gan to handle the un- certainties of renewable generation. It is expected that a large number of deferrable for the random fluctuations in renewable generation. Work on deferrable load control falls into two categories

  15. Agent-based Control for Material Handling Systems in In-House Logistics

    E-Print Network [OSTI]

    Agent-based Control for Material Handling Systems in In-House Logistics Towards Cyber-Physical Systems in In-House-Logistics Utilizing Realsize Evaluation of Agent-based Material Handling Technology Werthmann Intelligent Production and Logistics Systems BIBA ­ Bremer Institut für Produktion und Logistik

  16. Health Hazards in Indoor Air

    E-Print Network [OSTI]

    Logue, Jennifer M.

    2012-01-01

    Health Hazards in Indoor Air. In Proceedings of the 2010for VOCs from post-1990 indoor air concentration studies inUnion project on indoor air pollutants. Allergy, 2008. 63(

  17. Texas Clean Air Act (Texas)

    Broader source: Energy.gov [DOE]

    This Act is designed to safeguard the state's air resources from pollution by requiring the control and abatement of air pollution and emissions of air contaminants, consistent with the protection...

  18. Air heating system

    DOE Patents [OSTI]

    Primeau, John J. (19800 Seminole Rd., Euclid, OH 44117)

    1983-03-01

    A self-starting, fuel-fired, air heating system including a vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with the provision of heat exchanger and circuitry for cooling the condensed fluid output from the pump prior to its return to the vapor generator.

  19. The Air or Brayton Cycle Solvent Recovery System 

    E-Print Network [OSTI]

    Fox, B. J.

    1986-01-01

    it suitable for solvent recovery. Thi s unit util i zes ai r foil beari ngs. to recover the heat for useful purposes. It is easy Over the past several years they have sold. these for the air cycle system to return the solvent lean uni ts to condense... CYCLE SOLVENT RECOVERY SYSTEM Bryce J. Fox 3M Company St. Paul, ABSTRACT The required temperature and technique for condensing common industrial solvents from the exhaust air of drying ovens is explained. ?:The benefits of the Air Cycle...

  20. United States Air Force Air Logistics Centers : lean enterprise transformation and associated capabilities

    E-Print Network [OSTI]

    Cohen, Jessica L. (Jessica Lauren)

    2005-01-01

    Lean enterprise transformation entails a complementary set of initiatives and efforts executed over a substantial period of time, in a consistent and coordinated manner, at all levels of the enterprise. It builds upon ...

  1. Compressed Air Systems

    Broader source: Energy.gov [DOE]

    There are incentives for variable frequency drive screw compressors (10-40 HP), air receivers/tanks for load/no-load compressors, cycling refrigerated dryers (up to 200 CFM capacity), no-loss...

  2. Air conditioning system

    DOE Patents [OSTI]

    Lowenstein, Andrew; Miller, Jeffrey; Gruendeman, Peter; DaSilva, Michael

    2005-02-01

    An air conditioner comprises a plurality of plates arranged in a successively stacked configuration with portions thereof having a spaced apart arrangement, and defining between successive adjacent pairs of plates at the spaced apart portions a first and second series of discrete alternating passages wherein a first air stream is passed through the first series of passages and a second air stream is passed through the second series of passages; and said stacked configuration of plates forming integrally therewith a liquid delivery means for delivering from a source a sufficient quantity of a liquid to the inside surfaces of the first series of fluid passages in a manner which provides a continuous flow of the liquid from a first end to a second end of the plurality of plates while in contact with the first air stream.

  3. Guide to Air Sealing

    SciTech Connect (OSTI)

    2011-02-01

    Air sealing is one of the most cost-effective ways to improve the comfort and energy efficiency of your home. Hire a certified professional contractor for best results.

  4. Air bag restraint device

    DOE Patents [OSTI]

    Marts, D.J.; Richardson, J.G.

    1995-10-17

    A rear-seat air bag restraint device is disclosed that prevents an individual, or individuals, from continuing violent actions while being transported in a patrol vehicle`s rear seat without requiring immediate physical contact by the law enforcement officer. The air bag is activated by a control switch in the front seat and inflates to independently restrict the amount of physical activity occurring in the rear seat of the vehicle while allowing the officer to safely stop the vehicle. The air bag can also provide the officer additional time to get backup personnel to aid him if the situation warrants it. The bag is inflated and maintains a constant pressure by an air pump. 8 figs.

  5. Combustion Air Control 

    E-Print Network [OSTI]

    Hughart, C. L.

    1979-01-01

    to 100%. If the air and fuel controls are on automatic but the flue gas oxygen content cannot be lowered to 4% oxygen without the boiler smoking, burner problems may be suspected. The trouble may be traced to dirty or improperly assembled oil guns..., combustion air distribution problems, vaporizing steam control problems, oil viscosity, or flow control problems. It is very important to have all oil guns operating properly before proceeding with a combustion test. The minimum stack gas oxygen level you...

  6. Outdoor unit construction for an electric heat pump

    DOE Patents [OSTI]

    Draper, R.; Lackey, R.S.

    1984-09-11

    The outdoor unit for an electric heat pump is provided with an upper portion containing propeller fan means for drawing air through the lower portion containing refrigerant coil means in the form of four discrete coils connected together in a subassembly forming a W shape, the unit being provided with four adjustable legs which are retracted in shipment, and are adjusted on site to elevate the unit to a particular height suitable for the particular location in which the unit is installed. 4 figs.

  7. Outdoor unit construction for an electric heat pump

    DOE Patents [OSTI]

    Draper, Robert (Pittsburgh, PA); Lackey, Robert S. (Pittsburgh, PA)

    1984-01-01

    The outdoor unit for an electric heat pump is provided with an upper portion 10 containing propeller fan means 14 for drawing air through the lower portion 12 containing refrigerant coil means 16 in the form of four discrete coils connected together in a subassembly forming a W shape, the unit being provided with four adjustable legs 64 which are retracted in shipment, and are adjusted on site to elevate the unit to a particular height suitable for the particular location in which the unit is installed.

  8. UNITED STATES DEPARTMENT OF THE INTERIOR U.S. FIsH AND WILDLIFE SERVICII

    E-Print Network [OSTI]

    . FL 359 Manufacturers of equipment for the fish processing industries. FL 374 Freezing and canning Crab pot construction (Chesapeake Bay type). Freezing and canning king crab. Pasteurization of crab meat. Dungeness crab pots . Edible crabs of the United States . FL 498 Culture. handling

  9. UCHC Competency Checklist: ANNUAL Position Title: Registered Nurse, JDH Employee Name: Unit: Cancer Center

    E-Print Network [OSTI]

    Oliver, Douglas L.

    COMPETENCIES Alaris Pump-use of guardrails, secondary infusion tubing V LEVEL 3: UNIT SPECIFIC COMPETENCIES Alaris Pump ­ use of new chemotherapy administration tubing (Infusion RN) V, RD 5-FU Infusion Pump (Infusion RN) V Safe Handling of Hazardous Drugs ­ Proper PPE and Double Gloving B. DOCUMENTATION

  10. Development of a Laboratory Verified Single-Duct VAV System Model with Fan Powered Terminal Units Optimized Using Computational Fluid Dynamics 

    E-Print Network [OSTI]

    Davis, Michael A.

    2011-10-21

    Single Duct Variable Air Volume (SDVAV) systems use series and parallel Fan Powered Terminal Units to control the air flow in conditioned spaces. This research developed a laboratory verified model of SDVAV systems that ...

  11. Homeowner's Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet), Building America Case Study: Technology Solutions for Existing Homes, Building Technologies Office (BTO)

    SciTech Connect (OSTI)

    Not Available

    2013-06-01

    This fact sheet offers a step-by-step guide to proper installation of window air conditioning units, in order to improve efficiency and comfort for homeowners.

  12. ver the past fifty years, thousands of workers in the United States have handled plutonium. Of those workers, only about

    E-Print Network [OSTI]

    Massey, Thomas N.

    was thus a stable source of radiation for hundreds of years The Human Plutonium Injection Experiments 224 of the risk of plutonium to humans and much of the public's perceptions about the dangers of radioactive "Ionizing Radiation--It's Everywhere!" pages 24-25, for a discussion of radioac- tive half-life). Radium

  13. inAir: Sharing Indoor Air Quality Measurements and Visualizations

    E-Print Network [OSTI]

    Mankoff, Jennifer

    evidence has indicated that indoor air pollution within homes and other buildings can be worse than the outdoor air pollution in even the largest and most industrialized cities. For example, the California Air Resources Board estimates that indoor air pollutant levels are 25-62% greater than outside levels [4

  14. inAir: Sharing Indoor Air Quality Measurements and Visualizations

    E-Print Network [OSTI]

    Paulos, Eric

    the outdoor air pollution in even the largest and most industrialized cities. For example, the California Air evidence has indicated that indoor air pollution within homes and other buildings can be worse than Resources Board estimates that indoor air pollutant levels are 25-62% greater than outside levels [4

  15. Experimental Study in Energy Performance of Temperature and Humidity Independent Control System with Multiple Split Air-Conditioning System 

    E-Print Network [OSTI]

    Kawano,M.

    2014-01-01

    ? [k W h] E le ct ri c p o w e r co n su m p ti o n ? kW h /y e a r? 12,000 10,0 8,0 6,0 4,0 2,0 0 Outdoor air-conditioning unit Indoor unit Outdoor unit A Humidity Control unit Indoor unit Outdoor unit Outdoor air-conditioning unit A Humidity... Control unit Indoor unit Outdoor unit Developed system onventional system E le ct ri c p o w e r co n su m p ti o n ? kW h /m o n th ? 1,400 1,200 1,000 800 600 400 200 0 E le ct ri c p o w e r co n su m p ti o n ? kW h /m o n th ? 1,400 1,200 1,000 800...

  16. Proposal for Construction/Demonstration/Implementation of A Material Handling System

    SciTech Connect (OSTI)

    Jim Jnatt

    2001-08-24

    Vortec Corporation, the United States Enrichment Corporation (USEC) and DOE/Paducah propose to complete the technology demonstration and the implementation of the Material Handling System developed under Contract Number DE-AC21-92MC29120. The demonstration testing and operational implementation will be done at the Paducah Gaseous Diffusion Plant. The scope of work, schedule and cost for the activities are included in this proposal. A description of the facility to be constructed and tested is provided in Exhibit 1, attached. The USEC proposal for implementation at Paducah is presented in Exhibit 2, and the commitment letters from the site are included in Exhibit 3. Under our agreements with USEC, Bechtel Jacobs Corporation and DOE/Paducah, Vortec will be responsible for the construction of the demonstration facility as documented in the engineering design package submitted under Phase 4 of this contract on August 9, 2001. USEC will have responsibility for the demonstration testing and commercial implementation of the plant. The demonstration testing and initial commercial implementation of the technology will be achieved by means of a USEC work authorization task with the Bechtel Jacobs Corporation. The initial processing activities will include the processing of approximately 4,250 drums of LLW. Subsequent processing of LLW and TSCA/LLW will be done under a separate contract or work authorization task. To meet the schedule for commercial implementation, it is important that the execution of the Phase 4 project option for construction of the demonstration system be executed as soon as possible. The schedule we have presented herein assumes initiation of the construction phase by the end of September 2001. Vortec proposes to complete construction of the demonstration test system for an estimated cost of $3,254,422. This price is based on the design submitted to DOE/NETL under the Phase 4 engineering design deliverable (9 august 2001). The cost is subject to the assumptions and conditions identified in Section 6 of this proposal.

  17. Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers

    SciTech Connect (OSTI)

    Coles, Henry C.; Han, Taewon; Price, Phillip N.; Gadgil, Ashok J.; Tschudi, William F.

    2011-07-17

    There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: closed and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percent age of the recirculation air is make-up air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both closed and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups: (1) Outside - coupons sheltered, located near or at the supply air inlet, but located before any filtering, (2) Supply - starting just after initial air filtering continuing inside the plenums and ducts feeding the data center rooms, and (3) Inside located inside the data center rooms near the IT equipment. Each coupon was exposed for thirty days and then sent to a laboratory for a corrosion rate measurement analysis. The goal of this research was to investigate whether gaseous contamination is a concern for U.S. data center operators as it relates to the reliability of IT equipment. More specifically, should there be an increased concern if outside air for IT equipment cooling is used To begin to answer this question limited exploratory measurements of corrosion rates in operating data centers in various locations were undertaken. This study sought to answer the following questions: (1) What is the precision of the measurements (2) What are the approximate statistical distributions of copper and silver corrosion rates in the sampled data centers(3) To what extent are copper and silver corrosion measurements related (4) What is the relationship of corrosion rate measurements between outside-air cooled data centers compared to closed data centers (5) How do corrosivity measurements relate to IT equipment failure rates The data from our limited sample size suggests that most United States data center operators should not be concerned with environmental gaseous contamination causing high IT equipment failure rates even when using outside-air cooling. The research team recommends additional basic research on how environmental conditions, specifically gaseous contamination, affect electronic equipment reliability.

  18. PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED INTO A DWELLING

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED.peuportier@mines-paristech.fr, Tel.: +33 1 40 51 91 51 ABSTRACT An inverter-driven air-to-air heat pump model has been developped capacity air-to-air heat pump coupled with temperate air sources (crawlspace, attic, sunspace, heat

  19. Preliminary Safety Design Report for Remote Handled Low-Level Waste Disposal Facility

    SciTech Connect (OSTI)

    Timothy Solack; Carol Mason

    2012-03-01

    A new onsite, remote-handled low-level waste disposal facility has been identified as the highest ranked alternative for providing continued, uninterrupted remote-handled low-level waste disposal for remote-handled low-level waste from the Idaho National Laboratory and for nuclear fuel processing activities at the Naval Reactors Facility. Historically, this type of waste has been disposed of at the Radioactive Waste Management Complex. Disposal of remote-handled low-level waste in concrete disposal vaults at the Radioactive Waste Management Complex will continue until the facility is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). This preliminary safety design report supports the design of a proposed onsite remote-handled low-level waste disposal facility by providing an initial nuclear facility hazard categorization, by discussing site characteristics that impact accident analysis, by providing the facility and process information necessary to support the hazard analysis, by identifying and evaluating potential hazards for processes associated with onsite handling and disposal of remote-handled low-level waste, and by discussing the need for safety features that will become part of the facility design.

  20. Conceptual Safety Design Report for the Remote Handled Low-Level Waste Disposal Facility

    SciTech Connect (OSTI)

    Boyd D. Christensen

    2010-02-01

    A new onsite, remote-handled LLW disposal facility has been identified as the highest ranked alternative for providing continued, uninterrupted remote-handled LLW disposal for remote-handled LLW from the Idaho National Laboratory and for spent nuclear fuel processing activities at the Naval Reactors Facility. Historically, this type of waste has been disposed of at the Radioactive Waste Management Complex. Disposal of remote-handled LLW in concrete disposal vaults at the Radioactive Waste Management Complex will continue until the facility is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). This conceptual safety design report supports the design of a proposed onsite remote-handled LLW disposal facility by providing an initial nuclear facility hazard categorization, by identifying potential hazards for processes associated with onsite handling and disposal of remote-handled LLW, by evaluating consequences of postulated accidents, and by discussing the need for safety features that will become part of the facility design.

  1. Conceptual Safety Design Report for the Remote Handled Low-Level Waste Disposal Facility

    SciTech Connect (OSTI)

    Boyd D. Christensen

    2010-05-01

    A new onsite, remote-handled LLW disposal facility has been identified as the highest ranked alternative for providing continued, uninterrupted remote-handled LLW disposal for remote-handled LLW from the Idaho National Laboratory and for spent nuclear fuel processing activities at the Naval Reactors Facility. Historically, this type of waste has been disposed of at the Radioactive Waste Management Complex. Disposal of remote-handled LLW in concrete disposal vaults at the Radioactive Waste Management Complex will continue until the facility is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). This conceptual safety design report supports the design of a proposed onsite remote-handled LLW disposal facility by providing an initial nuclear facility hazard categorization, by identifying potential hazards for processes associated with onsite handling and disposal of remote-handled LLW, by evaluating consequences of postulated accidents, and by discussing the need for safety features that will become part of the facility design.

  2. NNSA, Air Force Complete Successful B61-12 Life Extension Program...

    National Nuclear Security Administration (NNSA)

    (NNSA) and United States Air Force completed the third development flight test of a non-nuclear B61-12 nuclear gravity bomb at Tonopah Test Range in Nevada on October...

  3. Saving Energy and Reducing Emissions from the Regeneration Air System of a Butane Dehydrogenation Plant 

    E-Print Network [OSTI]

    John, T. P.

    1998-01-01

    Texas Petrochemicals operates a butane dehydrogenation unit producing MTBE for reformulated gasoline that was originally constructed when energy was cheap and prior to environmental regulation. The process exhausts 900,000 pounds per hour of air...

  4. United States of Agriculture

    E-Print Network [OSTI]

    United States Department of Agriculture DESIGN: A Program to Create Data Forest Service Entry Research Work Unit at the Station's Forest Fire Laboratory, 4955 Canyon Crest Drive, Riverside, CA 92507

  5. United Sates Environmental Protection

    E-Print Network [OSTI]

    Bowen, James D.

    United Sates Environmental Protection Agency Office of Water (4305) EPA/823/B/95/003 August 1995 QUAL2E Windows Interface User's Guide #12;QUAL2E Windows Interface User's Guide United States

  6. United States of Agriculture

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Research Station General Observatory in Stinson Beach, Calif. Thomas E. Martin is Assistant Unit Leader--Wildlife at the U.S. Fish

  7. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Forest and Range, objectives, and targets and specific work plans for the field units--the National Forests and their Ranger

  8. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Northwest Research Station Research, and export from 1997 to 2010, for main world regions and the United States. Detailed tables by country

  9. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Peelflc Southwest Forest and Range that are expressed in tems familim to the user. Theboard footand cubic footare mdiriond units of measure, altlnough

  10. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Northeastern Research Station Research Paper-Central United States (Monserud and Ek 1977; Monserud 1987). This model was used within the framework of FOREST

  11. United States Department of

    E-Print Network [OSTI]

    #12;United States Department of Agriculture Forest Service Pacific Southwest Research Station for the Station's Wildland Recreation and the Urban Culture Research Work Unit, located at the Forest Fire

  12. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Usual Planting and Harvesting Dates for U.S. Field Crops million acres of barley were harvested in the United States (U.S.) during 1996. After reaching a peak

  13. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Northwest Research Station Research, import, and export from 1997 to 2010, for main world regions and the United States. Detailed tables

  14. air traffic the polytechnic school

    E-Print Network [OSTI]

    air traffic management the polytechnic school innovation.asu.edu #12;undergraduate degree program B.S., air traffic management Our undergraduate air traffic management program offers students exceptional training and state-of-the-art air traffic control simulators to enhance and reinforce classroom study. You

  15. Air Distribution Retrofit Strategies for Affordable Housing

    SciTech Connect (OSTI)

    Dentz, J.; Conlin, F.; Holloway, Parker; Podorson, David; Varshney, Kapil

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

  16. Aircraft vertical profiles of trace gas and aerosol pollution over the mid-Atlantic United States: Statistics and meteorological cluster

    E-Print Network [OSTI]

    Thompson, Anne

    measurements of O3, CO, SO2, and aerosol properties were made during summertime air pollution episodes over. Introduction [2] In 1992, in response to mounting air pollution prob- lems over the mid-Atlantic United States holistic, long-term air quality studies in the region and analyzing transboundary pollution transport

  17. United States Department of

    E-Print Network [OSTI]

    Estimated UseofWaterintheUnitedStatesin2005 Trends in estimated water use in the United States.L., Hutson, S.S., Linsey, K.S., Lovelace, J.K., and Maupin, M.A., 2009, Estimated use of water in the United

  18. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Forest and Range unit investigating measurement and analysis techniques for management planning, with headquarters in Berkeley, Calif. ELLIOT L. AMIDON is now assigned to the Station's unit at Arcata, Calif., that is studying

  19. United States of Agriculture

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Intermountain Research Station Research Research Station's Riparian-Stream Ecology and Management Research Work Unit at Boise, ID. He re- ceived with the Intermountain Research Station's Riparian-Stream Ecology and Man- agement Research Work Unit at the Forestry

  20. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Northeastern Research Station General Estimates for Forest Types of the United States James E. Smith Linda S. Heath Kenneth E. Skog Richard A forest types within 10 regions of the United States. Separate tables were developed for afforestation

  1. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service General Technical #12;- TH ,a geneticist, is assigned to the Station's research unit dyin etics of western forest trees, with headquarters in Berkeley, Berkeley. PAUL D. cal technician with the genetics research unit, isa forestry gra California, Berkeley

  2. United States Department of

    E-Print Network [OSTI]

    Clements, Craig

    United States Department of Agriculture Forest Service Intermountain Research Station Ogden, UT. He was project leader of the fire fundamentals research work unit from 1966 until 1979 and is currently project leader of the fire behavior research work unit at the fire sciences laboratory. RALPH A

  3. United States Department of

    E-Print Network [OSTI]

    Liebhold, Andrew

    United States Department of Agriculture Forest Service Northeastern Research Station Research Paper of the Eastern United States have been devastated by invasive pests. We used existing data to predict-quarter in total host density. Gypsy moth occupies only 23 percent of its potential range in the Eastern United

  4. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Forest and Range Thomas J. Mills Frederick W. Bratten #12;The Authors: are with the Station's research unit studying fire J. MILLS, a forest economist, is in charge of the unit. He earned degrees at Michigan State

  5. United States of Agriculture

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Research Station General,000 xylem resin samples of pine (Pinus) species and hybrids--largely from the western United States locations in the eastern and southern United States. Cover Image: Chapter 6, Figure 6-2. #12;Xylem

  6. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Forest and Range ecosystemsresearch unit located in Riverside. California. PAUL H. DUNN was project leader at that time and is now project leader of the atmospheric deposition research unit in Riverside. Calif. SUSAN C. BARRO

  7. United States Department of

    E-Print Network [OSTI]

    United States Department of Proceedings of the Agriculture Pacific Southwest Symposium on Social of Agriculture; 96 p. The growing demand for recreation at the wildland-urban interface throughout the United and the Urban Culture Research Unit headquartered at the Forest Fire Laboratory, 4955 Canyon Crest Dr

  8. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Pacific Southwest Research Station http. Arbaugh is a statistician with the Station's Atmospheric Deposition Effects Research Unit at Riverside and associate professor with the National Park Service Cooperative Park Studies Unit, College of Forest

  9. United States Department of

    E-Print Network [OSTI]

    Holberton, Rebecca L.

    United States Department of Agriculture Forest Service Northeastern Research Station General Technical Report NE-318 Atlas of Climate Change Effects in 150 Bird Species of the Eastern United States Service 359 Main Road Delaware, OH 43015 USA #12;United States Department of Agriculture Forest Service

  10. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Northeastern Research Station Research Paper NE-722 James E. Smith Linda S. Heath A Model of Forest Floor Carbon Mass for United States Forest contiguous United States. Manuscript received for publication 22 April 2002 #12;A Model of Forest Floor

  11. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Southern Research Station General Technical United States. In: Rauscher, H. Michael, and Kurt Johnsen, eds. Southern forest science: past, present Trends in the Southern United States Robert A. Mickler, James E. Smith, and Linda S. Heath1 Abstract

  12. UNITED STATES PARTMENT OF

    E-Print Network [OSTI]

    UNITED STATES PARTMENT OF lMMERCE J8l1CATION SEATTLE, WA IOVEMBER 1973 FISHERY FACTS-6 U. S of foreign fishing off United States coastal waters, and the aevelopment and enforce- ment of international;ABSTRACT Dungeness crabs, Cancer magister, occur in the inshore waters of t he west coast of the United

  13. United States Department of

    E-Print Network [OSTI]

    United States Department of Agriculture Forest Service Northeastern Research Station General reported in USDA Forest Service surveys for forests of the conterminous United States. Developed for use estimates are provided for regional tree-mass totals using summary forest statistics for the United States

  14. United States Nuclear Regulatory

    E-Print Network [OSTI]

    United States Nuclear Regulatory Commission United States Department of Energy United States.S. Nuclear Regulatory Commission Washington, DC 20555-0001 E-mail: DISTRIBUTION@nrc.gov Facsimile: 301; and Commission papers and their attachments. NRC publications in the NUREG series, NRC regulations, and Title 10

  15. Unit Testing Discussion C

    E-Print Network [OSTI]

    Massachusetts at Amherst, University of

    Unit Testing Discussion C #12;Unit Test public Method is smallest unit of code Input/output transformation Test if the method does what it claims Not exactly black box testing #12;Test if (actual result Expected Computed Input #12;Functionality Computation ­ Easy to test Time based Asynchronous interaction

  16. The Macroscopic Cortical Unit

    E-Print Network [OSTI]

    Penny, Will

    The Macroscopic Brain Will Penny Cortical Unit Neural Mass Model Cell Populations Differential Will Penny 21st April 2011 #12;The Macroscopic Brain Will Penny Cortical Unit Neural Mass Model Cell as formulated in David et al. (2006). #12;The Macroscopic Brain Will Penny Cortical Unit Neural Mass Model Cell

  17. Compressed air energy storage system

    DOE Patents [OSTI]

    Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

    1981-01-01

    An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

  18. Power Handling of the Bulk Tungsten Divertor Row at JET: First Measurements and Comparison to the GTM Thermal Model

    E-Print Network [OSTI]

    Power Handling of the Bulk Tungsten Divertor Row at JET: First Measurements and Comparison to the GTM Thermal Model

  19. Development of an Outdoor Concentrating Photovoltaic Module Testbed, Module Handling and Testing Procedures, and Initial Energy Production Results

    SciTech Connect (OSTI)

    Muller, M.

    2009-09-01

    This report addresses the various aspects of setting up a CPV testbed and procedures for handling and testing CPV modules.

  20. Installation and Operation of Sorbathene Solvent Vapor Recovery Units to Recover and Recycle Volatile Organic Compounds at Operating Sites within the Dow Chemical Company 

    E-Print Network [OSTI]

    Hall, T. L.; Larrinaga, L.

    1994-01-01

    hydrocarbons, chlorofluorocarbons (CFC's), chlorinated solvents, aromatics, and monomers. SORBATHENE units are now meeting air permit requirements for the abatement of VOC's such as benzene, acetone, trichloroethylene, trichlorofluoromethane, carbon...

  1. Model-Based Commissioning for Filters in Room Air Conditioners 

    E-Print Network [OSTI]

    Wang, F.; Yoshida, H.; Kitagawa, H.; Matsumoto, K.; Goto, K.

    2004-01-01

    This paper proposes a model that can estimate filter resistance. Two sorts of value are used as inputs to estimate filter resistance. One is the power consumed by the fan in the indoor unit and the other is the thermal performance. For the room air...

  2. Energy conservation by partial recirculation of peanut drying air

    SciTech Connect (OSTI)

    Young, J.H.

    1983-06-01

    Conventional, recirculating, and intermittent type peanut dryers were compared in a three-year study. Comparisons indicate that partial recirculation of peanut drying air may reduce energy consumption per unit of water removed by approximately 25% while also reducing required drying time and maintaining high quality.

  3. QUANTIFYING THE POTENTIAL IMPACTS OF ATMS ON AIR QUALITY Bruce Hellinga

    E-Print Network [OSTI]

    Hellinga, Bruce

    pollution. Currently, in the United States, motor vehicles release up to 90% of the carbon monoxide (CO); and more than 50% of the hazardous air pollutants [1]. Many of the air pollutants emitted by motor vehicles spatially and temporally correlated pollutant emissions on the basis of a drive mode elemental emissions sub

  4. Effect of a Radiant Panel Cooling System on Indoor Air Quality of a Conditioned Space 

    E-Print Network [OSTI]

    Mohamed, E.; Abdalla, K. N.

    2010-01-01

    This paper discusses the effect of a radiant cooling panel system on an indoor air quality (IAQ) of a conditioned space. In this study, ceiling radiant cooling panel, mechanical ventilation with fan coil unit (FCU) and 100% fresh air are used...

  5. Portable air monitoring laboratories

    SciTech Connect (OSTI)

    Ehntholt, D.J.; Beltis, K.J.; McCullough, J.E.; Valentine, J.R. [Arthur D. Little, Inc., Cambridge, MA (United States)

    1995-12-31

    Arthur D. Little, Inc. was contracted by the US Army to design, fabricate, test and deliver a series of portable air monitoring laboratories which could be used to detect trace levels of toxic chemicals on board cargo ships. The labs were designed to be completely self-sufficient, containing all supplies necessary for a 75-day mission, and to operate under rugged conditions. They were used to monitor for parts-per-billion concentrations of chemical agents in air and to provide information equivalent to high quality fixed laboratory analyses. The mission was successfully completed; independent design awards were received for the laboratories, and they were subsequently diverted to other uses.

  6. ARRA Material Handling Equipment Composite Data Products: Data Through Quarter 4 of 2012

    SciTech Connect (OSTI)

    Kurtz, J.; Sprik, S.; Ainscough, C.; Saur, G.; Post, M.; Peters, M.; Ramsden, T.

    2013-05-01

    This presentation from the U.S. Department of Energy's National Renewable Energy Laboratory includes American Recovery and Reinvestment Act (ARRA) fuel cell material handling equipment composite data products for data through the fourth quarter of 2012.

  7. ARRA Material Handling Equipment Composite Data Products: Data through Quarter 2 of 2012

    SciTech Connect (OSTI)

    Kurtz, J.; Sprik, S.; Ramsden, T.; Ainscough, C.; Saur, G.

    2012-10-01

    This presentation from the U.S. Department of Energy's National Renewable Energy Laboratory includes American Recovery and Reinvestment Act (ARRA) fuel cell material handling equipment composite data products for data through the second quarter of 2012.

  8. Bike Handling, Safety, Comfort, and Group Riding Bike and Build Workshop, June 4, 2004

    E-Print Network [OSTI]

    Stange, Katherine E.

    Handling for Safety Wear a Helmet Understand the physics of bicycle riding o How your bike stays upright "NO" · Menace with pump, or squirt water bottle · Better to stop than to crash (dogs usually lose

  9. Webinar: Analysis Using Fuel Cell Material Handling Equipment for Shaving Peak Building Energy

    Office of Energy Efficiency and Renewable Energy (EERE)

    Access the recording and download the presentation slides from the Fuel Cell Technologies Office webinar "Analysis Using Fuel Cell Material Handling Equipment (MHE) for Shaving Peak Building Energy" held on August 11, 2015.

  10. ARRA Material Handling Equipment Composite Data Products: Data through Quarter 2 of 2013

    SciTech Connect (OSTI)

    Kurtz, J.; Sprik, S.; Ainscough, C.; Saur, G.; Post, M.; Peters, M.

    2013-11-01

    This report includes 47 composite data products (CDPs) produced for American Recovery and Reinvestment Act (ARRA) fuel cell material handling equipment, with data through the second quarter of 2013.

  11. A MICROFLUIDIC MAGNETIC HYBRID ACTUATOR FOR ADVANCED HANDLING FUNCTIONS AT CELL RESOLUTION

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    A MICROFLUIDIC MAGNETIC HYBRID ACTUATOR FOR ADVANCED HANDLING FUNCTIONS-CNRS, Toulouse, FRANCE 2 Université de Toulouse, Toulouse, FRANCE *email : mfouet@laas.fr In microfluidics are usually integrated. Coils were thus integrated to microfluidic chips

  12. ARRA Material Handling Equipment Composite Data Products: Data Through Quarter 4 of 2013

    SciTech Connect (OSTI)

    Kurtz, J.; Sprik, S.; Peters, M.

    2014-06-01

    This report includes 47 composite data products (CDPs) produced for American Recovery and Reinvestment Act (ARRA) fuel cell material handling equipment, with data through the fourth quarter of 2013.

  13. LWR NUCLEAR FUEL BUNDLE DATA FOR USE IN FUEL BUNDLE HANDLING

    Office of Scientific and Technical Information (OSTI)

    LWR NUCLEAR FUEL BUNDLE DATA FOR USE IN FUEL BUNDLE HANDLING TOPICAL REPORT W. 8. Weihermilfer C. S. Allison Septem bet 1979 Work Performed, Under Contract EY-76-C- M - 1 8 3 0...

  14. Remote-Handled Low-Level Waste Disposal Project Code of Record

    SciTech Connect (OSTI)

    S.L. Austad, P.E.; L.E. Guillen, P.E.; C. W. McKnight, P.E.; D. S. Ferguson, P.E.

    2012-06-01

    The Remote-Handled Low-Level Waste (LLW) Disposal Project addresses an anticipated shortfall in remote-handled LLW disposal capability following cessation of operations at the existing facility, which will continue until it is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). Development of a new onsite disposal facility will provide necessary remote-handled LLW disposal capability and will ensure continuity of operations that generate remote-handled LLW. This report documents the Code of Record for design of a new LLW disposal capability. The report is owned by the Design Authority, who can authorize revisions and exceptions. This report will be retained for the lifetime of the facility.

  15. Remote-Handled Low-Level Waste Disposal Project Code of Record

    SciTech Connect (OSTI)

    S.L. Austad, P.E.; L.E. Guillen, P.E.; C. W. McKnight, P.E.; D. S. Ferguson, P.E.

    2011-01-01

    The Remote-Handled Low-Level Waste (LLW) Disposal Project addresses an anticipated shortfall in remote-handled LLW disposal capability following cessation of operations at the existing facility, which will continue until it is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). Development of a new onsite disposal facility, the highest ranked alternative, will provide necessary remote-handled LLW disposal capability and will ensure continuity of operations that generate remote-handled LLW. This report documents the Code of Record for design of a new LLW disposal capability. The report is owned by the Design Authority, who can authorize revisions and exceptions. This report will be retained for the lifetime of the facility.

  16. Remote-Handled Low-Level Waste Disposal Project Code of Record

    SciTech Connect (OSTI)

    Austad, S. L.; Guillen, L. E.; McKnight, C. W.; Ferguson, D. S.

    2015-04-01

    The Remote-Handled Low-Level Waste (LLW) Disposal Project addresses an anticipated shortfall in remote-handled LLW disposal capability following cessation of operations at the existing facility, which will continue until it is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). Development of a new onsite disposal facility will provide necessary remote-handled LLW disposal capability and will ensure continuity of operations that generate remote-handled LLW. This report documents the Code of Record for design of a new LLW disposal capability. The report is owned by the Design Authority, who can authorize revisions and exceptions. This report will be retained for the lifetime of the facility.

  17. Remote-Handled Low-Level Waste Disposal Project Code of Record

    SciTech Connect (OSTI)

    S.L. Austad, P.E.; L.E. Guillen, P.E.; C. W. McKnight, P.E.; D. S. Ferguson, P.E.

    2014-06-01

    The Remote-Handled Low-Level Waste (LLW) Disposal Project addresses an anticipated shortfall in remote-handled LLW disposal capability following cessation of operations at the existing facility, which will continue until it is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). Development of a new onsite disposal facility will provide necessary remote-handled LLW disposal capability and will ensure continuity of operations that generate remote-handled LLW. This report documents the Code of Record for design of a new LLW disposal capability. The report is owned by the Design Authority, who can authorize revisions and exceptions. This report will be retained for the lifetime of the facility.

  18. Remote-Handled Low-Level Waste Disposal Project Code of Record

    SciTech Connect (OSTI)

    S.L. Austad, P.E.; L.E. Guillen, P.E.; C. W. McKnight, P.E.; D. S. Ferguson, P.E.

    2012-04-01

    The Remote-Handled Low-Level Waste (LLW) Disposal Project addresses an anticipated shortfall in remote-handled LLW disposal capability following cessation of operations at the existing facility, which will continue until it is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). Development of a new onsite disposal facility will provide necessary remote-handled LLW disposal capability and will ensure continuity of operations that generate remote-handled LLW. This report documents the Code of Record for design of a new LLW disposal capability. The report is owned by the Design Authority, who can authorize revisions and exceptions. This report will be retained for the lifetime of the facility.

  19. Remote-Handled Low-Level Waste Disposal Project Code of Record

    SciTech Connect (OSTI)

    S.L. Austad, P.E.; L.E. Guillen, P.E.; C. W. McKnight, P.E.; D. S. Ferguson, P.E.

    2011-04-01

    The Remote-Handled Low-Level Waste (LLW) Disposal Project addresses an anticipated shortfall in remote-handled LLW disposal capability following cessation of operations at the existing facility, which will continue until it is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). Development of a new onsite disposal facility, the highest ranked alternative, will provide necessary remote-handled LLW disposal capability and will ensure continuity of operations that generate remote-handled LLW. This report documents the Code of Record for design of a new LLW disposal capability. The report is owned by the Design Authority, who can authorize revisions and exceptions. This report will be retained for the lifetime of the facility.

  20. Criticality Safety Evaluation Report for the Cold Vacuum Drying (CVD) Facilities Process Water Handling System

    SciTech Connect (OSTI)

    KESSLER, S.F.

    2000-08-10

    This report addresses the criticality concerns associated with process water handling in the Cold Vacuum Drying Facility. The controls and limitations on equipment design and operations to control potential criticality occurrences are identified.

  1. Construction and operation of replacement hazardous waste handling facility at Lawrence Berkeley Laboratory. Environmental Assessment

    SciTech Connect (OSTI)

    Not Available

    1992-09-01

    The US Department of Energy (DOE) has prepared an environmental assessment (EA), DOE/EA-0423, for the construction and operation of a replacement hazardous waste handling facility (HWHF) and decontamination of the existing HWHF at Lawrence Berkeley Laboratory (LBL), Berkeley, California. The proposed facility would replace several older buildings and cargo containers currently being used for waste handling activities and consolidate the LBL`s existing waste handling activities in one location. The nature of the waste handling activities and the waste volume and characteristics would not change as a result of construction of the new facility. Based on the analysis in the EA, DOE has determined that the proposed action would not constitute a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) of 1969, 42 USC. 4321 et seq. Therefore, an environmental impact statement is not required.

  2. High Efficiency Room Air Conditioner

    SciTech Connect (OSTI)

    Bansal, Pradeep

    2015-01-01

    This project was undertaken as a CRADA project between UT-Battelle and Geberal Electric Company and was funded by Department of Energy to design and develop of a high efficiency room air conditioner. A number of novel elements were investigated to improve the energy efficiency of a state-of-the-art WAC with base capacity of 10,000 BTU/h. One of the major modifications was made by downgrading its capacity from 10,000 BTU/hr to 8,000 BTU/hr by replacing the original compressor with a lower capacity (8,000 BTU/hr) but high efficiency compressor having an EER of 9.7 as compared with 9.3 of the original compressor. However, all heat exchangers from the original unit were retained to provide higher EER. The other subsequent major modifications included- (i) the AC fan motor was replaced by a brushless high efficiency ECM motor along with its fan housing, (ii) the capillary tube was replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and (iii) the unit was tested with a drop-in environmentally friendly binary mixture of R32 (90% molar concentration)/R125 (10% molar concentration). The WAC was tested in the environmental chambers at ORNL as per the design rating conditions of AHAM/ASHRAE (Outdoor- 95F and 40%RH, Indoor- 80F, 51.5%RH). All these modifications resulted in enhancing the EER of the WAC by up to 25%.

  3. A Review of Toxicity and Use and Handling Considerations for Guanidine, Guanidine Hydrochloride, and Urea.

    SciTech Connect (OSTI)

    Ertell, Katherine GB

    2006-03-27

    This is a technical report prepared for Oregon Sustainable Energy, LLC, under Agreement 06-19 with PNNL's Office of Small Business Programs. The request was to perform a review of the toxicity and safe handling of guanidine. The request was later amended to add urea. This report summarizes the toxicity data available in the scientific literature and provides an interpretation of the results and recommendations for handling these compounds.

  4. EIS-0453: Recapitalization of Infrastructure Supporting Naval Spent Nuclear Fuel Handling at the Idaho National Laboratory

    Broader source: Energy.gov [DOE]

    The Draft EIS evaluates the potential environmental impacts associated with recapitalizing the infrastructure needed to ensure the long-term capability of the Naval Nuclear Propulsion Program (NNPP) to support naval spent nuclear fuel handling capabilities provided by the Expended Core Facility (ECF). Significant upgrades are necessary to ECF infrastructure and water pools to continue safe and environmentally responsible naval spent nuclear fuel handling until at least 2060.

  5. Unit 51 - GIS Application Areas

    E-Print Network [OSTI]

    Unit 51, CC in GIS; Cowen, David; Ferguson, Warren

    1990-01-01

    51 - GIS APPLICATION AREAS UNIT 51 - GIS APPLICATION AREAS1990 Page 1 Unit 51 - GIS Application Areas Computers inyour students. UNIT 51 - GIS APPLICATION AREAS Compiled with

  6. Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York)

    Broader source: Energy.gov [DOE]

    These regulations establish emissions limits and permitting and operational requirements for facilities that may contribute to air emissions. General air quality standards and standards for...

  7. Canned Air in China

    E-Print Network [OSTI]

    Hacker, Randi

    2013-10-23

    Broadcast Transcript: Not that long ago, coal smoke made the air here in Beijing so caustic that your nasal passages were seared with each breath. Those were the good old days: Car ownership was limited to government officials and the rest...

  8. Modeling of ECM Controlled Series Fan-powered VAV Terminal Units 

    E-Print Network [OSTI]

    Yin, Peng

    2011-10-21

    Semi-empirical models for series fan-powered variable air volume terminal units (FPTUs) were developed based on models of the primary, plenum, fan airflow and the fan power consumption. The experimental setups and test procedures were developed...

  9. United Technologies Corporation: Achieving Competitive Excellence (ACE): Operating System Case Study

    E-Print Network [OSTI]

    Roth, George

    2010-11-30

    United Technologies Corporation (abbreviated UTC, NYSE ticker symbol UTX) is a large, industrial conglomerate that designs, manufactures, and services a broad range of products, ranging from air conditioners and elevators ...

  10. Compressed Air 101: Getting Compressed Air to Work 

    E-Print Network [OSTI]

    Burke, J. J.; Bessey, E. G.

    2003-01-01

    "Air compressors are a significant industrial energy user. Based on a survey (conducted by Oregon State University and the Bonneville Power Administration) of energy audit reports from 125 plants, air compressors account for roughly 10% of total...

  11. Vermont Air Pollution Control Regulations, Ambient Air Quality Standards (Vermont)

    Broader source: Energy.gov [DOE]

    The ambient air quality standards are based on the national ambient air quality standards. The Vermont standards are classified as primary and secondary standards and judged adequate to protect...

  12. Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics 

    E-Print Network [OSTI]

    Graham, E. L.

    1980-01-01

    Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

  13. Abatement of Air Pollution: The Clean Air Interstate Rule (CAIR...

    Broader source: Energy.gov (indexed) [DOE]

    may apply to fossil-fuel fired emission units, and describe nitrogen emission allocations that owners of such units must meet. The regulations also contain provisions for...

  14. DEVELOPMENT OF A HYDRONIC ROOFTOP UNIT -- HYPAK

    SciTech Connect (OSTI)

    Eric Lee; Dick Bourne; Mark Berman

    2004-03-25

    The majority of US commercial floor space is cooled by rooftop HVAC units (RTU's). RTU popularity derives chiefly from their low initial cost and relative ease of service access without disturbing building occupants. Unfortunately, current RTU's are inherently inefficient due to a combination of characteristics that unnecessarily increase cooling loads and energy use. Existing RTU's in the U.S. consume an estimated 2.4 quads annually. Inefficient RTU's create an estimated 3.5% of U.S. CO{sub 2} emissions, thus contributing significantly to global warming. Also, RTU's often fail to maintain adequate ventilation air and air filtration. This project was developed to evaluate the feasibility of a radically new ''HyPak'' RTU design that significantly and cost-effectively increases RTU performance and delivered air quality. The objective of the HyPak Project was to design, develop and test a hydronic RTU that provides a quantum improvement over conventional RTU performance. Our proposal targeted 60% and 50% reduction in electrical energy use by the HyPak RTU for dry and humid climates, respectively, when compared with a conventional unit.

  15. The investigation of exhaust powered, automotive air cycle air conditioning 

    E-Print Network [OSTI]

    Holley, James Andrew

    1978-01-01

    TEE INVESTIGATION OF EXHAUST POWERED, AUTOMOTIVE AIR CYCLE AIR CONDITIONING A Thesis James Andrew Holley Submitted to the Graduate College of Texas ASM University in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE... August 1978 Major SubJect: Mechanical Engineering THE INVESTIGATION OF EXHAUST POWERED, AUTOMOTIVE AIR CYCLE AIR CONDITIONING A Thesis hy James Andrew Holley Approved as to style and content by: Chairman of Committee) (Head of Departm nt) Memb e...

  16. Environmental Pollution Air Pollution Dispersion Practical Air Pollution Dispersion

    E-Print Network [OSTI]

    Moncrieff, John B.

    Environmental Pollution Air Pollution Dispersion 1 of 5 Practical ­ Air Pollution Dispersion in the lectures how such models can be used to explain observed concentrations of air pollutants in an area and to test `what-if' scenarios for pollution control and reduction. You will use the Gaussian Plume Model

  17. Social Media: Air Quality #SummerSafety

    E-Print Network [OSTI]

    than adults to the health effects caused by air pollution. http://cdc.gov/air/air_health.htm #SummerSafety Twitter: Children and teens may be more sensitive than adults to air pollution. http://cdc.gov/air/air Social Media: Air Quality #SummerSafety Please help the NWS spread these important safety

  18. United States Department of

    E-Print Network [OSTI]

    ..............................................................................2 Solid Waste Management .........................................................................3 ....................................................................................4 Solid Waste ManagementUnited States Department of Returns on InvestmentsAgriculture Forest Service in Management Sciences

  19. " Million Housing Units, Final...

    U.S. Energy Information Administration (EIA) Indexed Site

    3 Structural and Geographic Characteristics of U.S. Homes, by Year of Construction, 2009" " Million Housing Units, Final" ,,"Year of Construction" ,"Total U.S.1 (millions)"...

  20. Sustainable Energy --without the hot air David J.C. MacKay

    E-Print Network [OSTI]

    MacKay, David J.C.

    units. Energies are expressed as quan­ CONSUMPTION PRODUCTION Wind: 20 kWh/d Wave: 4 kWh/d Solar heating units that appear on household energy bills; and powers are expressed in kilowatt­hours per day (k1 Sustainable Energy -- without the hot air David J.C. MacKay Synopsis We have an addiction