Powered by Deep Web Technologies
Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles  

E-Print Network (OSTI)

Most air handling units (AHUs) in commercial buildings have an air economizer cycle for free cooling under certain outside air conditions. During the economizer cycle, the outside air and return air dampers are modulated to seek mixing air temperature at supply air temperature setpoint. Mechanical cooling is always required when outside air temperature is higher than the supply air temperature setpoint. Generally the supply air temperature setpoint is set at 55°F for space humidity control. Actually the dehumidification is not necessary when outside air dew point is less than 55°F. Meanwhile the space may have less cooling load due to envelope heat loss and/or occupant schedule. These provide an opportunity to use higher supply air temperature to reduce or eliminate mechanical cooling and terminal box reheat. On the other hand the higher supply air temperature will require higher air flow as well as higher fan power. Therefore the supply air temperature has to be optimized to minimize the combined energy for fan, cooling and heating energy. In this paper a simple energy consumption model is established for AHU systems during the economizer and then a optimal supply air temperature control is developed to minimize the total cost of the mechanical cooling and the fan motor power. This paper presents AHU system energy modeling, supply air temperature optimization, and simulated energy savings.

Xu, K.; Liu, M.; Wang, G.; Wang, Z.

2007-01-01T23:59:59.000Z

2

Supply Fan Control for Constant Air Volume Air Handling Units  

E-Print Network (OSTI)

Since terminal boxes do not have a modulation damper in constant volume (CV) air handling unit (AHU) systems, zone reheat coils have to be modulated to maintain the space temperature with constant supply airflow. This conventional control sequence causes a significant amount of reheat and constant fan power under partial load conditions. Variable Frequency Drives (VFDs) can be installed on these constant air volume systems. The fan speed can be modulated based on the maximum zone load. This paper present the procedure to control the supply fan speed and analyzes the thermal performance and major fan energy and thermal energy savings without expensive VAV retrofit through the actual system operation.

Cho, Y.; Wang, G.; Liu, M.

2007-01-01T23:59:59.000Z

3

Economizer Applications in Dual-Duct Air-Handling Units  

E-Print Network (OSTI)

This paper provides analytical tools and engineering methods to evaluate the feasibility of the economizer for dual-duct air-handling units. The results show that the economizer decreases cooling energy consumption without heating energy penalties for dual-fan, dual-duct air-handling units. The economizer has significant heating energy penalties for single-fan, dual-duct air-handling units. The penalties are higher than the cooling energy savings when the cold airflow is less than the hot airflow. Detailed engineering analyses are required to evaluate the feasibility of the economizer for single-fan, dual-duct systems.

Joo, I.; Liu, M.

2002-01-01T23:59:59.000Z

4

Proposal for the award of a contract for the supply, installation and modification of air-handling systems for the LHC  

E-Print Network (OSTI)

This document concerns the award of a contract for the supply, installation and modification of air-handling systems for the LHC. The Finance Committee is invited to agree to the negotiation of a contract with AMEC SPIE (DE), the lowest bidder after realignment, for the supply, installation and modification of air-handling systems for the LHC for a total amount of 8 222 490 euros (12 511 396 Swiss francs), not subject to revision. The rate of exchange used is that stipulated in the tender.

2004-01-01T23:59:59.000Z

5

Ash Handling System Maintenance Guide  

Science Conference Proceedings (OSTI)

This Ash Handling System Maintenance Guide provides fossil plant maintenance personnel with current maintenance information on this system. This guide will assist plant maintenance personnel in improving the reliability and reducing the maintenance costs for the ash handling system.

2005-12-23T23:59:59.000Z

6

WASTE HANDLING BUILDING ELECTRICAL SYSTEM DESCRIPTION DOCUMENT  

SciTech Connect

The Waste Handling Building Electrical System performs the function of receiving, distributing, transforming, monitoring, and controlling AC and DC power to all waste handling building electrical loads. The system distributes normal electrical power to support all loads that are within the Waste Handling Building (WHB). The system also generates and distributes emergency power to support designated emergency loads within the WHB within specified time limits. The system provides the capability to transfer between normal and emergency power. The system provides emergency power via independent and physically separated distribution feeds from the normal supply. The designated emergency electrical equipment will be designed to operate during and after design basis events (DBEs). The system also provides lighting, grounding, and lightning protection for the Waste Handling Building. The system is located in the Waste Handling Building System. The system consists of a diesel generator, power distribution cables, transformers, switch gear, motor controllers, power panel boards, lighting panel boards, lighting equipment, lightning protection equipment, control cabling, and grounding system. Emergency power is generated with a diesel generator located in a QL-2 structure and connected to the QL-2 bus. The Waste Handling Building Electrical System distributes and controls primary power to acceptable industry standards, and with a dependability compatible with waste handling building reliability objectives for non-safety electrical loads. It also generates and distributes emergency power to the designated emergency loads. The Waste Handling Building Electrical System receives power from the Site Electrical Power System. The primary material handling power interfaces include the Carrier/Cask Handling System, Canister Transfer System, Assembly Transfer System, Waste Package Remediation System, and Disposal Container Handling Systems. The system interfaces with the MGR Operations Monitoring and Control System for supervisory monitoring and control signals. The system interfaces with all facility support loads such as heating, ventilation, and air conditioning, office, fire protection, monitoring and control, safeguards and security, and communications subsystems.

S.C. Khamamkar

2000-06-23T23:59:59.000Z

7

Air-Cooled Stack Freeze Tolerance Freeze Failure Modes and Freeze Tolerance Strategies for GenDriveTM Material Handling Application Systems and Stacks Final Scientific Report  

Science Conference Proceedings (OSTI)

Air-cooled stack technology offers the potential for a simpler system architecture (versus liquid-cooled) for applications below 4 kilowatts. The combined cooling and cathode air allows for a reduction in part count and hence a lower cost solution. However, efficient heat rejection challenges escalate as power and ambient temperature increase. For applications in ambient temperatures below freezing, the air-cooled approach has additional challenges associated with not overcooling the fuel cell stack. The focus of this project was freeze tolerance while maintaining all other stack and system requirements. Through this project, Plug Power advanced the state of the art in technology for air-cooled PEM fuel cell stacks and related GenDrive material handling application fuel cell systems. This was accomplished through a collaborative work plan to improve freeze tolerance and mitigate freeze-thaw effect failure modes within innovative material handling equipment fuel cell systems designed for use in freezer forklift applications. Freeze tolerance remains an area where additional research and understanding can help fuel cells to become commercially viable. This project evaluated both stack level and system level solutions to improve fuel cell stack freeze tolerance. At this time, the most cost effective solutions are at the system level. The freeze mitigation strategies developed over the course of this project could be used to drive fuel cell commercialization. The fuel cell system studied in this project was Plug Power's commercially available GenDrive platform providing battery replacement for equipment in the material handling industry. The fuel cell stacks were Ballard's commercially available FCvelocity 9SSL (9SSL) liquid-cooled PEM fuel cell stack and FCvelocity 1020ACS (Mk1020) air-cooled PEM fuel cell stack.

Hancock, David, W.

2012-02-14T23:59:59.000Z

8

WASTE HANDLING BUILDING VENTILATION SYSTEM DESCRIPTION DOCUMENT  

SciTech Connect

The Waste Handling Building Ventilation System provides heating, ventilation, and air conditioning (HVAC) for the contaminated, potentially contaminated, and uncontaminated areas of the Monitored Geologic Repository's (MGR) Waste Handling Building (WHB). In the uncontaminated areas, the non-confinement area ventilation system maintains the proper environmental conditions for equipment operation and personnel comfort. In the contaminated and potentially contaminated areas, in addition to maintaining the proper environmental conditions for equipment operation and personnel comfort, the contamination confinement area ventilation system directs potentially contaminated air away from personnel in the WHB and confines the contamination within high-efficiency particulate air (HEPA) filtration units. The contamination confinement areas ventilation system creates airflow paths and pressure zones to minimize the potential for spreading contamination within the building. The contamination confinement ventilation system also protects the environment and the public by limiting airborne releases of radioactive or other hazardous contaminants from the WHB. The Waste Handling Building Ventilation System is designed to perform its safety functions under accident conditions and other Design Basis Events (DBEs) (such as earthquakes, tornadoes, fires, and loss of the primary electric power). Additional system design features (such as compartmentalization with independent subsystems) limit the potential for cross-contamination within the WHB. The system provides status of important system parameters and equipment operation, and provides audible and/or visual indication of off-normal conditions and equipment failures. The Waste Handling Building Ventilation System confines the radioactive and hazardous material within the building such that the release rates comply with regulatory limits. The system design, operations, and maintenance activities incorporate ALARA (as low as is reasonably achievable) principles to maintain personnel radiation doses to all occupational workers below regulatory limits and as low as is reasonably achievable. The Waste Handling Building Ventilation System interfaces with the Waste Handling Building System by being located within the WHB and by maintaining specific pressures, temperatures, and humidity within the building. The system also depends on the WHB for water supply. The system interfaces with the Site Radiological Monitoring System for continuous monitoring of the exhaust air; the Waste Handling Building Fire Protection System for detection of fire and smoke; the Waste Handling Building Electrical System for normal, emergency, and standby power; and the Monitored Geologic Repository Operations Monitoring and Control System for monitoring and control of the system.

P.A. Kumar

2000-06-21T23:59:59.000Z

9

Automatic Continuous Commissioning of Measurement Instruments in Air Handling Units  

E-Print Network (OSTI)

This paper presents a robust strategy based on a condition-based adaptive statistical method for automatic commissioning of measurement instruments typically employed in air-handling units (AHU). The multivariate statistic method, principal component analysis (PCA), is adopted and modified to monitor the air handling process. Two PCA models are built corresponding to the heat balance and pressure-flow balance of the air-handling process. Sensor faults can be detected and isolated using the Q-statistic and the Q-contribution plot. The fault isolation ability against typical component faults is improved using knowledge-based analysis. A novel condition-based adaptive scheme is developed to update the PCA models with the operation conditions for continuous online application. A commissioning tool is developed to implement the strategy. Simulation tests and field tests in a building in Hong Kong were conducted to validate the automatic commissioning strategy for typical AHU. The integration of the tool with a building management system (BMS) and its application is demonstrated.

Xiao, F.; Wang, S.

2006-01-01T23:59:59.000Z

10

DISPOSAL CONTAINER HANDLING SYSTEM DESCRIPTION DOCUMENT  

Science Conference Proceedings (OSTI)

The Disposal Container Handling System receives and prepares new disposal containers (DCs) and transfers them to the Assembly Transfer System (ATS) or Canister Transfer System (CTS) for loading. The system receives the loaded DCs from ATS or CTS and welds the lids. When the welds are accepted the DCs are termed waste packages (WPs). The system may stage the WP for later transfer or transfer the WP directly to the Waste Emplacement/Retrieval System. The system can also transfer DCs/WPs to/from the Waste Package Remediation System. The Disposal Container Handling System begins with new DC preparation, which includes installing collars, tilting the DC upright, and outfitting the container for the specific fuel it is to receive. DCs and their lids are staged in the receipt area for transfer to the needed location. When called for, a DC is put on a cart and sent through an airlock into a hot cell. From this point on, all processes are done remotely. The DC transfer operation moves the DC to the ATS or CTS for loading and then receives the DC for welding. The DC welding operation receives loaded DCs directly from the waste handling lines or from interim lag storage for welding of the lids. The welding operation includes mounting the DC on a turntable, removing lid seals, and installing and welding the inner and outer lids. After the weld process and non-destructive examination are successfully completed, the WP is either staged or transferred to a tilting station. At the tilting station, the WP is tilted horizontally onto a cart and the collars removed. The cart is taken through an air lock where the WP is lifted, surveyed, decontaminated if required, and then moved into the Waste Emplacement/Retrieval System. DCs that do not meet the welding non-destructive examination criteria are transferred to the Waste Package Remediation System for weld preparation or removal of the lids. The Disposal Container Handling System is contained within the Waste Handling Building System. This includes the primary hot cell bounded by the receiving area and WP transport exit air locks; and isolation doors at ATS, CTS, and Waste Package Remediation. The hot cell includes areas for welding, various staging, tilting, and WP transporter loading. There are associated operating galleries and equipment maintenance areas outside the hot cell. These areas operate concurrently to accommodate the DC/WP throughput rates and support system maintenance. The new DC preparation area is located in an unshielded structure. The handling equipment includes DC/WP bridge cranes, tilting stations, and horizontal transfer carts. The welding area includes DC/WP welders and staging stations. Welding operations are supported by remotely operated equipment including a bridge crane and hoists, welder jib cranes, welding turntables, and manipulators. WP transfer includes a transfer/decontamination and transporter load area. The transfer operations are supported by a remotely operated horizontal lifting system, decontamination system, decontamination and inspection manipulator, and a WP horizontal transfer cart. All handling operations are supported by a suite of fixtures including collars, yokes, lift beams, and lid attachments. Remote equipment is designed to facilitate decontamination and maintenance. Interchangeable components are provided where appropriate. Set-aside areas are included, as required, for fixtures and tooling to support off-normal and recovery operations. Semi-automatic, manual, and backup control methods support normal, maintenance, and recovery operations. The system interfaces with the ATS and CTS to provide empty and receive loaded DCs. The Waste Emplacement/Retrieval System interfaces are for loading/unloading WPs on/from the transporter. The system also interfaces with the Waste Package Remediation System for DC/WP repair. The system is housed, shielded, supported, and has ventilation boundaries by the Waste Handling Building (WHB). The system is ventilated by the WHB Ventilation System, which in conjunction with ventilation boundaries ensure that ai

E. F. Loros

2000-06-30T23:59:59.000Z

11

A plug and play framework for an HVAC air handling unit and temperature sensor auto recognition technique.  

E-Print Network (OSTI)

??A plug and play framework for an HVAC air handling unit control system is proposed in this study. This is the foundation and the first… (more)

Zhou, Xiaohui

2010-01-01T23:59:59.000Z

12

CARRIER/CASK HANDLING SYSTEM DESCRIPTION DOCUMENT  

Science Conference Proceedings (OSTI)

The Carrier/Cask Handling System receives casks on railcars and legal-weight trucks (LWTs) (transporters) that transport loaded casks and empty overpacks to the Monitored Geologic Repository (MGR) from the Carrier/Cask Transport System. Casks that come to the MGR on heavy-haul trucks (HHTs) are transferred onto railcars before being brought into the Carrier/Cask Handling System. The system is the interfacing system between the railcars and LWTs and the Assembly Transfer System (ATS) and Canister Transfer System (CTS). The Carrier/Cask Handling System removes loaded casks from the cask transporters and transfers the casks to a transfer cart for either the ATS or CTS, as appropriate, based on cask contents. The Carrier/Cask Handling System receives the returned empty casks from the ATS and CTS and mounts the casks back onto the transporters for reshipment. If necessary, the Carrier/Cask Handling System can also mount loaded casks back onto the transporters and remove empty casks from the transporters. The Carrier/Cask Handling System receives overpacks from the ATS loaded with canisters that have been cut open and emptied and mounts the overpacks back onto the transporters for disposal. If necessary, the Carrier/Cask Handling System can also mount empty overpacks back onto the transporters and remove loaded overpacks from them. The Carrier/Cask Handling System is located within the Carrier Bay of the Waste Handling Building System. The system consists of cranes, hoists, manipulators, and supporting equipment. The Carrier/Cask Handling System is designed with the tooling and fixtures necessary for handling a variety of casks. The Carrier/Cask Handling System performance and reliability are sufficient to support the shipping and emplacement schedules for the MGR. The Carrier/Cask Handling System interfaces with the Carrier/Cask Transport System, ATS, and CTS as noted above. The Carrier/Cask Handling System interfaces with the Waste Handling Building System for building structures and space allocations. The Carrier/Cask Handling System interfaces with the Waste Handling Building Electrical System for electrical power.

E.F. Loros

2000-06-23T23:59:59.000Z

13

Cask system design guidance for robotic handling  

SciTech Connect

Remote automated cask handling has the potential to reduce both the occupational exposure and the time required to process a nuclear waste transport cask at a handling facility. The ongoing Advanced Handling Technologies Project (AHTP) at Sandia National Laboratories is described. AHTP was initiated to explore the use of advanced robotic systems to perform cask handling operations at handling facilities for radioactive waste, and to provide guidance to cask designers regarding the impact of robotic handling on cask design. The proof-of-concept robotic systems developed in AHTP are intended to extrapolate from currently available commercial systems to the systems that will be available by the time that a repository would be open for operation. The project investigates those cask handling operations that would be performed at a nuclear waste repository facility during cask receiving and handling. The ongoing AHTP indicates that design guidance, rather than design specification, is appropriate, since the requirements for robotic handling do not place severe restrictions on cask design but rather focus on attention to detail and design for limited dexterity. The cask system design features that facilitate robotic handling operations are discussed, and results obtained from AHTP design and operation experience are summarized. The application of these design considerations is illustrated by discussion of the robot systems and their operation on cask feature mock-ups used in the AHTP project. 11 refs., 11 figs.

Griesmeyer, J.M.; Drotning, W.D.; Morimoto, A.K.; Bennett, P.C.

1990-10-01T23:59:59.000Z

14

Optimal Outside Air Control for Air Handling Units with Humidity Control  

E-Print Network (OSTI)

Most air handling units (AHUs) in commercial buildings have the (air) economizer cycle to use outside air for free cooling under certain outside air conditions. Ideally the economizer cycle is enabled if outside air enthalpy is less than return air enthalpy. During the economizer cycle, outside air flow is modulated to seek mixed air temperature at a supply air temperature set point. Since the outside air may be dry during the economizer cycle, humidification is required for AHUs with humidity control. As a result, the economizer cycle saves cooling energy but requires excessive steam for humidification. Therefore the economizer cycle may not be economical. An optimal outside air control method is developed to minimize the total cost of mechanical cooling and steam humidification. The impacts of chilled water price, steam price, and space minimum humidity set point are analyzed. Finally the optimal outside air control zones are presented on a psychrometric chart under differential energy price ratios and minimum indoor humidity set points.

Wang, G.; Liu, M.

2006-01-01T23:59:59.000Z

15

Determining Critical Pressure and Duct Leakage in VAV Air-Handling Units  

NLE Websites -- All DOE Office Websites (Extended Search)

Determining Critical Pressure and Duct Leakage in VAV Air-Handling Units Determining Critical Pressure and Duct Leakage in VAV Air-Handling Units Speaker(s): Clifford Federspiel Date: December 3, 2003 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Nance Matson Fans for moving air in buildings use a significant amount of energy. It is well known that fan energy use in variable-air-volume (VAV) systems can be reduced by resetting the supply duct pressure. The standard way to reset duct pressure is by controlling the most-open terminal damper to a nearly open position. Most systems can't measure terminal damper positions, so pressures are either not reset at all or use ad hoc resetting strategies that are configured sub-optimally. In this seminar I will describe a new method of determining the critical supply duct pressure for VAV systems.

16

Zoned heating and air conditioning system  

SciTech Connect

This patent describes a zoned heating and air conditioning system comprising: a central air handling system with an air heating means and an air cooling means and a blower connected to an air duct system; thermostats each have heating and cooling set points, respectively associated with and located in different zones of a building; dampers respectively associated with each building zone positioned in the air duct system. Each damper has an open position allowing air into the respective zone from the duct system and a closed position; relay means for connecting one thermostat to the air handling system upon a call for heating or cooling by one thermostat and disconnecting all other thermostats by connecting one thermostat's connections between the thermostat and air handling system. Only one thermostat is connected to the air handling system at a time and the relay means disconnects one thermostat from the air handling system after one thermostat is satisified; and damper actuating means for unlocking each damper in one building zone responsive actuated by a respective zone thermostat connected to the air handling system by the relay means. The damper actuates means including a damper solenoid for each damper located adjacent each damper and connected to a respective zone thermostat. It unlocks each damper in one building zone responsive to being actuated by the respective zone thermostat and unlocks the dampers in one building zone when one thermostat is actuated while preventing the dampers in another thermostat's building zone from unlocking.

Beachboard, S.A.

1987-06-16T23:59:59.000Z

17

Performance Analysis of Dual-Fan, Dual-Duct Constant Volume Air-Handling Units  

E-Print Network (OSTI)

Dual-fan, dual-duct air-handling units introduce outside air directly into the cooling duct and use two variable speed devices to independently maintain the static pressure of the hot and the cold air ducts. Analytical models have been developed to compare fan power and thermal energy consumption of dualfan, dual-duct constant volume air-handling units with single-fan, dual-duct constant volume airhandling units. This study shows that the dual-fan, dual-duct system uses less fan power and less thermal energy during winter, and uses more thermal energy during summer. Thermal energy performance can be significantly improved if the thermal energy penalty can be decreased or eliminated.

Joo, I. S.; Liu, M.

2001-01-01T23:59:59.000Z

18

LM Records Handling System (LMRHS01) - Rocky Flats Environmental...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

here Home LM Records Handling System (LMRHS01) - Rocky Flats Environmental Records Database, Office of Legacy Management LM Records Handling System (LMRHS01) - Rocky Flats...

19

LM Records Handling System (LMRHS01) - Electronic Records Keeping...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Publications LM Records Handling System (LMRHS01) - Rocky Flats Environmental Records Database, Office of Legacy Management LM Records Handling System (LMRHS01) - Energy Employees...

20

Water Management in Ash-Handling Systems  

Science Conference Proceedings (OSTI)

In 1980, EPA proposed revisions to the effluent standards and guidelines for fly ash and bottom ash transport systems. This review of utility practices provides a comprehensive account of the operation of and problems experienced in wet handling of bottom and fly ash and suggests areas for further research.

1987-08-24T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Self-Correcting HVAC Controls: Algorithms for Sensors and Dampers in Air-Handling Units  

SciTech Connect

This report documents the self-correction algorithms developed in the Self-Correcting Heating, Ventilating and Air-Conditioning (HVAC) Controls project funded jointly by the Bonneville Power Administration and the Building Technologies Program of the U.S. Department of Energy. The algorithms address faults for temperature sensors, humidity sensors, and dampers in air-handling units and correction of persistent manual overrides of automated control systems. All faults considered create energy waste when left uncorrected as is frequently the case in actual systems.

Fernandez, Nicholas; Brambley, Michael R.; Katipamula, Srinivas

2009-12-31T23:59:59.000Z

22

LM Records Handling System-Fernald Historical Records System...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Management, LM Records Handling System (LMRHS01) - Rocky Flats Environmental Records Database, Office of Legacy Management Energy.gov Careers & Internships For Staff & Contractors...

23

Analysis of the Energy-Saving Potential of a Three-Rotary Wheel Fresh Air-Handling Unit  

E-Print Network (OSTI)

To evaluate the energy-saving potential of a proposed three-rotary wheel fresh air-handling unit (TRWFAHU), it is numerically simulated with weather data of Changsha by using a mathematical model. Compared with a conventional fresh air-handling unit, TRWFAHU can save 10.2% of primary energy and greatly decrease the energy consumption of chiller. If waste heat is available for regenerating the desiccant, the system can achieve greater energy savings. It is feasible to improve indoor air quality (IAQ) by increasing ventilation while without increasing energy consumption.

Hao, X.; Zhang, G.; Zou, S.; Liu, H.

2006-01-01T23:59:59.000Z

24

System for handling and storing radioactive waste  

DOE Patents (OSTI)

A system and method for handling and storing spent reactor fuel and other solid radioactive waste, including canisters to contain the elements of solid waste, storage racks to hold a plurality of such canisters, storage bays to store these racks in isolation by means of shielded doors in the bays. This system also includes means for remotely positioning the racks in the bays and an access tunnel within which the remotely operated means is located to position a rack in a selected bay. The modular type of these bays will facilitate the construction of additional bays and access tunnel extension.

Anderson, John K. (San Diego, CA); Lindemann, Paul E. (Escondido, CA)

1984-01-01T23:59:59.000Z

25

System for handling and storing radioactive waste  

DOE Patents (OSTI)

A system and method are claimed for handling and storing spent reactor fuel and other solid radioactive waste, including canisters to contain the elements of solid waste, storage racks to hold a plurality of such canisters, storage bays to store these racks in isolation by means of shielded doors in the bays. This system also includes means for remotely positioning the racks in the bays and an access tunnel within which the remotely operated means is located to position a rack in a selected bay. The modular type of these bays will facilitate the construction of additional bays and access tunnel extension.

Anderson, J.K.; Lindemann, P.E.

1982-07-19T23:59:59.000Z

26

ENDTOEND REQUEST HANDLING IN DISTRIBUTED VIDEOONDEMAND SYSTEMS  

E-Print Network (OSTI)

that adequate storage and stream handling capacities are present at the servers in the remote clusters. In addition, the remote sites act as sources of supplemental request handling capacity minimizing overall service is delivered only when the local cluster can­ not handle the load. Between the two remote clusters

Mundur, Padma

27

Investigation of Feasibility of All-Fresh Air Supply in an All-Air System  

E-Print Network (OSTI)

The feasibility of an all-fresh air supply in an all-air system is investigated in theory, and the problem of AHU-handling air in low efficiency in summer and winter conditions is analyzed. The air supply temperature is almost up to standards when a heat recovery unit is fixed in the air conditioning system.

Wang, J.; Yan, Z.

2006-01-01T23:59:59.000Z

28

ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES  

SciTech Connect

Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear ES when used during unannounced inspections, design information verification, limited frequency unannounced access, and complementary access visits at bulk handling facilities. Analysis of technical features required for tamper indication and resistance will demonstrate the viability of successful application of the system in taking ES within a bulk handling location. Further exploration of putting this technology into practice is planned to include mapping uranium enrichment facilities for the identification of optimal for installation of air monitoring devices.

Sexton, L.; Hanks, D.; Degange, J.; Brant, H.; Hall, G.; Cable-Dunlap, P.; Anderson, B.

2011-06-07T23:59:59.000Z

29

Fuel handling system for a nuclear reactor  

DOE Patents (OSTI)

A pool type nuclear fission reactor has a core, with a plurality of core elements and a redan which confines coolant as a hot pool at a first end of the core separated from a cold pool at a second end of the core by the redan. A fuel handling system for use with such reactors comprises a core element storage basket located outside of the redan in the cold pool. An access passage is formed in the redan with a gate for opening and closing the passage to maintain the temperature differential between the hot pool and the cold pool. A mechanism is provided for opening and closing the gate. A lifting arm is also provided for manipulating the fuel core elements through the access passage between the storage basket and the core when the redan gate is open.

Saiveau, James G. (Hickory Hills, IL); Kann, William J. (Park Ridge, IL); Burelbach, James P. (Glen Ellyn, IL)

1986-01-01T23:59:59.000Z

30

Reagent Storage and Handling for SCR and SNCR Systems  

Science Conference Proceedings (OSTI)

As utilities move to post-combustion nitrogen oxides (NOx) control technologies, the need to understand reagent storage and handling requirements for these systems increases. This report reviews various approaches to the storage and handling of anhydrous ammonia, aqueous ammonia, and urea. Systems that convert urea to ammonia also are included.

2002-05-30T23:59:59.000Z

31

Feasibility Study of Developing a Virtual Chilled Water Flow Meter at Air Handling Unit Level  

E-Print Network (OSTI)

In this paper, a virtual Air handling unit (AHU) level water flow meter is explored by using a control valve as a measurement device. The flow through the valve is indirectly calculated using differential pressure over both the valve and its associated coil and valve stem position. Thus, the non-intrusive virtual flow meter introduced in this paper provides a solution to one of the measurement barriers and challenges: a low cost, reliable energy metering system at the AHU level. Mathematical models were built and the preliminary experiments were conducted to investigate the feasibility of the virtual flow meter applications. As a result, the valve flow meter can be a cost effective means for water flow measurements at the AHU and thus provides an effective index for detecting and diagnosing the AHU operation faults.

Song, L.; Swamy, A.; Shim, G.

2011-01-01T23:59:59.000Z

32

MERCURY HANDLING FOR THE TARGET SYSTEM FOR A MUON COLLIDER  

E-Print Network (OSTI)

Cryostat 1. Remote handling The high radiation levels and presence of hazardous, ac- tivated mercury vaporsMERCURY HANDLING FOR THE TARGET SYSTEM FOR A MUON COLLIDER Van Graves , ORNL, Oak Ridge, TN 37830 placement within the Shielding Module in a remote environment. · Providing double containment of the mercury

McDonald, Kirk

33

Handling effluent from nuclear thermal propulsion system ground tests  

SciTech Connect

A variety of approaches for handling effluent from nuclear thermal propulsion system ground tests in an environmentally acceptable manner are discussed. The functional requirements of effluent treatment are defined and concept options are presented within the framework of these requirements. System concepts differ primarily in the choice of fission-product retention and waste handling concepts. The concept options considered range from closed cycle (venting the exhaust to a closed volume or recirculating the hydrogen in a closed loop) to open cycle (real time processing and venting of the effluent). This paper reviews the different methods to handle effluent from nuclear thermal propulsion system ground tests.

Shipers, L.R.; Allen, G.C.

1992-09-09T23:59:59.000Z

34

Strategy Guideline: Compact Air Distribution Systems  

SciTech Connect

This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

Burdick, A.

2013-06-01T23:59:59.000Z

35

Transpired Solar Collector at NREL's Waste Handling Facility Uses Solar Energy to Heat Ventilation Air  

Energy.gov (U.S. Department of Energy (DOE))

Revised fact sheet describes the transpired solar collector that was installed on NREL's Waste handling Facility (WHF) in 1990 to preheat ventilation air. The electrically heated WHF was an ideal candidate for this technology - requiring a ventilation rate of 3,000 cubic feet per meter to maintain safe indoor conditions.

36

Method and system rapid piece handling  

DOE Patents (OSTI)

The advent of high-speed fabric cutters has made necessary the development of automated techniques for the collection and sorting of garment pieces into collated piles of pieces ready for assembly. The present invention enables a new method for such handling and sorting of garment parts, and to apparatus capable of carrying out this new method. The common thread is the application of computer-controlled shuttling bins, capable of picking up a desired piece of fabric and dropping it in collated order for assembly. Such apparatus with appropriate computer control relieves the bottleneck now presented by the sorting and collation procedure, thus greatly increasing the overall rate at which garments can be assembled.

Spletzer, Barry L. (9504 Arvilla, NE, Albuquerque, NM 87111)

1996-01-01T23:59:59.000Z

37

Exploring Maximum Humidity Control and Energy Conservation Opportunities with Single Duct Single Zone Air-Handling Units  

E-Print Network (OSTI)

Humidity control for single-duct single-zone (SDSZ) constant volume air handling units is known to be a challenge. The operation of these systems is governed by space temperature only. Under mild weather conditions, discharge air temperature can get much higher than the space dew point and the dehumidification capability of the system is diminished. Buildings served by this type of air handler often experience exceptionally high humidity levels under humid weather conditions. Many potential solutions and improvements exist. However, these solutions require system modifications or upgrades and therefore are less attractive to some facility owners. A Critical Humidity Control Program (CHCP) was developed to change the normal control sequence of the air-handling units during high humidity periods to help improve the moisture removal capability of the system. The program was not designed to solve the problem completely, but the overall humidity levels can be lowered and controlled within a reasonably low range (58% - 65%) for a significant part of the high humidity seasons. This approach is relatively easy to implement and does not require any hardware changes. This paper also summarizes various potential solutions to improve humidity control for SDSZ units. The advantages and disadvantages for each solution are compared.

Zhou, J.; Wei, G.; Turner, W. D.; Deng, S.; Claridge, D.

2006-01-01T23:59:59.000Z

38

Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature?  

E-Print Network (OSTI)

The supply air temperature set point for a singleduct constant air volume air handling unit (AHU) system is often reset based on either return air temperature or outside air temperature in order to reduce simultaneous cooling and heating energy consumption. Both reset strategies make engineering sense as long as the reset schedules are reasonable. Quite often the decision to use one over the other is made with the assumption that they will all achieve some sorts of energy savings. However, the impact of these two strategies on AHU energy consumption could be very different. A comparison of these two commonly used supply air temperature reset strategies for a single-duct constant air volume system is presented in this paper. It is shown that from either the building energy consumption or building comfort point of view, the reset strategy based on outside air temperature is inherently better than that based on return air temperature. Significant amount of heating energy savings can be achieved by switching from return air temperature based reset to outside air temperature based reset. The reset strategy can also benefit variable air volume (VAV) AHUs. An improved supply air temperature set point reset control strategy is proposed by combining and staging the outside air and return air temperature based resets.

Wei, G.; Turner, W. D.; Claridge, D.; Liu, M.

2002-01-01T23:59:59.000Z

39

Handling Global Conditions in Parameterized System Verification  

Science Conference Proceedings (OSTI)

We consider symbolic verification for a class of parameterized systems, where a system consists of a linear array of processes, and where an action of a process may in general be guarded by both local conditions restricting the state of the process about ...

Parosh Aziz Abdulla; Ahmed Bouajjani; Bengt Jonsson; Marcus Nilsson

1999-07-01T23:59:59.000Z

40

Determining Critical Pressure and Duct Leakage in VAV Air-Handling...  

NLE Websites -- All DOE Office Websites (Extended Search)

for moving air in buildings use a significant amount of energy. It is well known that fan energy use in variable-air-volume (VAV) systems can be reduced by resetting the supply...

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Air heating system  

DOE Patents (OSTI)

A self-starting, fuel-fired, air heating system including a vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with the provision of heat exchanger and circuitry for cooling the condensed fluid output from the pump prior to its return to the vapor generator.

Primeau, John J. (19800 Seminole Rd., Euclid, OH 44117)

1983-03-01T23:59:59.000Z

42

Optimizing Ash Handling - SmartAshTM System Evaluation  

Science Conference Proceedings (OSTI)

High ash levels in electrostatic precipitator (ESP) hoppers are notorious for increasing particulate matter (PM) emissions and plume opacity. Conventional means of monitoring hopper ash levels and fly ash handling system performance have been time-consuming and problematic. Neundorfer, Inc., has developed a fly ash conveying system-monitoring package (SmartAshSystem) that provides improved monitoring of fly ash removal process parameters and provides graphical depictions of ash system performance. Additi...

2007-11-21T23:59:59.000Z

43

Status of ITER neutral beam cell remote handling system  

E-Print Network (OSTI)

The ITER neutral beam cell will contain up to three heating neutral beams and one diagnostic neutral beam, and four upper ports. Though manual maintenance work is envisaged within the cell, when containment is breached, or the radiological protection is removed the maintenance must be conducted remotely. This maintenance constitutes the removal and replacement of line replaceable units, and their transport to and from a cask docked to the cell. A design of the remote handling system has been prepared to concept level which this paper describes including the development of a beam line transporter, beam source remote handling equipment, upper port remote handling equipment and equipment for the maintenance of the neutral shield. This equipment has been developed complete the planned maintenance tasks for the components of the neutral beam cell and to have inherent flexibility to enable as yet unforeseen tasks and recovery operations to be performed.

Sykes, N; Choi, C-H; Crofts, O; Crowe, R; Damiani, C; Delavalle, S; Meredith, L; Mindham, T; Raimbach, J; Tesini, A; Van Uffelen, M

2013-01-01T23:59:59.000Z

44

Compressed Air System Maintenance Guide  

Science Conference Proceedings (OSTI)

The "Compressed Air System Maintenance Guide" provides fossil plant personnel with information on the operation and maintenance of the compressed air system. The contents of this guide will assist personnel in improving performance of the compressed air system, reducing maintenance costs, and increasing air system reliability.

2002-11-27T23:59:59.000Z

45

CLASSIFICATION OF THE MGR WASTE HANDLING BUILDING ELECTRICAL SYSTEM  

SciTech Connect

The purpose of this analysis is to document the Quality Assurance (QA) classification of the Monitored Geologic Repository (MGR) waste handling building electrical system structures, systems and components (SSCs) performed by the MGR Safety Assurance Department. This analysis also provides the basis for revision of YMP/90-55Q, Q-List (YMP 1998). The Q-List identifies those MGR SSCs subject to the requirements of DOE/RW-0333P, ''Quality Assurance Requirements and Description'' (QARD) (DOE 1998).

S.E. Salzman

1999-08-31T23:59:59.000Z

46

Development and implementation of automated radioactive materials handling systems  

SciTech Connect

Material handling of radioactive and hazardous materials has forced the need to pursue remotely operated and robotic systems in light of operational safety concerns. Manual maneuvering, repackaging, overpacking and inspecting of containers which store radioactive and hazardous materials is the present mode of operation at the Department of Energy (DOE) Fernald Environmental Management Project (FEMP) in Fernald Ohio. The manual methods are unacceptable in the eyes of concerned site workers and influential community oversight committees. As an example to respond to the FEMP material handling needs, design efforts have been initiated to provide a remotely operated system to repackage thousands of degradated drums containing radioactive Thorium: Later, the repackaged Thorium will be shipped offsite to a predesignated repository again requiring remote operation.

Jacoboski, D.L.

1992-12-01T23:59:59.000Z

47

A sensor-based automation system for handling nuclear materials  

Science Conference Proceedings (OSTI)

An automated system is being developed for handling large payloads of radioactive nuclear materials in an analytical laboratory. The automation system performs unpacking and repacking of payloads from shipping and storage containers, and delivery of the payloads to the stations in the laboratory. The system uses machine vision and force/torque sensing to provide sensor-based control of the automation system in order to enhance system safety, flexibility, and robustness, and achieve easy remote operation. The automation system also controls the operation of the laboratory measurement systems and the coordination of them with the robotic system. Particular attention has been given to system design features and analytical methods that provide an enhanced level of operational safety. Independent mechanical gripper interlock and tool release mechanisms were designed to prevent payload mishandling. An extensive Failure Modes and Effects Analysis of the automation system was developed as a safety design analysis tool.

Drotning, W.; Kimberly, H.; Wapman, W.; Darras, D. [and others

1997-03-01T23:59:59.000Z

48

Coal- and Ash-Handling Systems Reliability Conference and Workshop Proceedings  

Science Conference Proceedings (OSTI)

This report presents papers, discussion summaries, and conclusions from an EPRI workshop on reliability problems with coal- and ash-handling systems in power plants. Held in October 1980 in St. Louis, the workshop covered yard and in-plant coal handling, frozen coal, fugitive dust, fly ash handling, bottom ash handling, and ash disposal.

1981-08-01T23:59:59.000Z

49

Handling Overload Conditions In High Performance Trustworthy Information Retrieval Systems  

E-Print Network (OSTI)

Web search engines retrieve a vast amount of information for a given search query. But the user needs only trustworthy and high-quality information from this vast retrieved data. The response time of the search engine must be a minimum value in order to satisfy the user. An optimum level of response time should be maintained even when the system is overloaded. This paper proposes an optimal Load Shedding algorithm which is used to handle overload conditions in real-time data stream applications and is adapted to the Information Retrieval System of a web search engine. Experiment results show that the proposed algorithm enables a web search engine to provide trustworthy search results to the user within an optimum response time, even during overload conditions.

Ramachandran, Sumalatha; Paulraj, Sujaya; Ramaraj, Vetriselvi

2010-01-01T23:59:59.000Z

50

Modelling and simulation of high capacity waterside container handling systems at deep-sea terminals  

Science Conference Proceedings (OSTI)

Current handling systems at deep-sea container terminals run into their physical limits and new methods of handling containers are needed to deal with the ever-growing container shipping volumes. We present a domain specific simulation model of high ... Keywords: adjustable simulation model, container handling system, container workflow, productivity improvement, quay crane concepts

F. Geldof; B. C. van Haarlem; W. Lock; E. E. Roubtsova

2008-04-01T23:59:59.000Z

51

Environments for Remote Teaching in Embedded Systems Courses Christian Trodhandl Thomas Handl Markus Proske Bettina Weiss  

E-Print Network (OSTI)

Environments for Remote Teaching in Embedded Systems Courses Christian Tr¨odhandl Thomas Handl points for discussion at the workshop: How to handle remote access? In a distance lab with a limited/2, 1040 Vienna, Austria {troedhandl,handl,proske,bw}@ecs.tuwien.ac.at 1 Introduction Embedded systems lab

52

Computer controlled air conditioning systems  

SciTech Connect

This patent describes an improvement in a computer controlled air conditioning system providing for circulation of air through an air conditioned house in contact with concrete walls requiring a humidity within a critical range. The improvement consists of: a computer for processing sensed environmental input data including humidity and oxygen to produce output control signals for affecting the humidity of the air in the house; provision for an air flow circulation path through the house in contact with the concrete walls; sensing responsive to the amount of oxygen in the house for providing input signals to the computer; mixing for combining with the air in the house a variable amount of fresh atmospheric air to supply fresh oxygen; and humidity modifying means for modifying the humidity of the air flowing in the flow path responsive to the control signals.

Dumbeck, R.F.

1986-02-04T23:59:59.000Z

53

Uncertainty Analysis for a Virtual Flow Meter Using an Air-Handling Unit Chilled Water Valve  

SciTech Connect

A virtual water flow meter is developed that uses the chilled water control valve on an air-handling unit as a measurement device. The flow rate of water through the valve is calculated using the differential pressure across the valve and its associated coil, the valve command, and an empirically determined valve characteristic curve. Thus, the probability of error in the measurements is significantly greater than for conventionally manufactured flow meters. In this paper, mathematical models are developed and used to conduct uncertainty analysis for the virtual flow meter, and the results from the virtual meter are compared to measurements made with an ultrasonic flow meter. Theoretical uncertainty analysis shows that the total uncertainty in flow rates from the virtual flow meter is 1.46% with 95% confidence; comparison of virtual flow meter results with measurements from an ultrasonic flow meter yielded anuncertainty of 1.46% with 99% confidence. The comparable results from the theoretical uncertainty analysis and empirical comparison with the ultrasonic flow meter corroborate each other, and tend to validate the approach to computationally estimating uncertainty for virtual sensors introduced in this study.

Song, Li; Wang, Gang; Brambley, Michael R.

2013-04-28T23:59:59.000Z

54

Octant 1 boom extension The JET remote handling system has been used  

E-Print Network (OSTI)

Octant 1 boom extension Background The JET remote handling system has been used since 1998 to maintain and modify components inside the torus. The efficiency of in-vessel remote handling activities study Remote handling Top: The Octant 1 boom prior to being extended Bottom: The fully assembled

55

Optimal Terminal Box Control for Single Duct Air-Handling Units  

E-Print Network (OSTI)

Terminal boxes maintain room temperature by modulating supply air temperature and airflow in building HVAC systems. Terminal boxes with conventional control sequences often supply inadequate airflow to a conditioned space, resulting in occupant discomfort, or provide excessive airflow that wastes significant reheat energy. In this study, an optimal terminal box airflow control sequence was developed to improve indoor ventilation and reduce energy consumption. The developed control sequence was applied in an office building air conditioning system. Improvements in indoor thermal comfort and energy reduction were verified through measurement. The results show that the optimal control sequence can stably maintain thermal environment, satisfy comfort standards and reduce energy consumption compared to the conventional control sequence.

Cho, Y.; Vondal, J.; Wang, G.; Liu, M.

2006-01-01T23:59:59.000Z

56

Air ejector augmented compressed air energy storage system  

DOE Patents (OSTI)

Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air pressure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

1980-01-01T23:59:59.000Z

57

An Innovative Approach for Data Collection and Handling to Enable Advancements in Micro Air Vehicle Persistent Surveillance  

E-Print Network (OSTI)

The success of unmanned aerial vehicles (UAV) in the Iraq and Afghanistan conflicts has led to increased interest in further digitalization of the United States armed forces. Although unmanned systems have been a tool of the military for several decades, only recently have advances in the field of Micro-Electro-Mechanical Systems (MEMS) technology made it possible to develop systems capable of being transported by an individual soldier. These miniature unmanned systems, more commonly referred to as micro air vehicles (MAV), are envisioned by the Department of Defense as being an integral part of maintaining America?s military superiority. As researchers continue to make advances in the miniaturization of flight hardware, a new problem with regard to MAV field operations is beginning to present itself. To date, little work has been done to determine an effective means of collecting, analyzing, and handling information that can satisfy the goal of using MAVs as tools for persistent surveillance. Current systems, which focus on the transmission of analog video streams, have been very successful on larger UAVs such as the RQ-11 Raven but have proven to be very demanding of the operator. By implementing a new and innovative data processing methodology, currently existing hardware can be adapted to effectively present critical information with minimal user input. Research currently being performed at Texas A&M University in the areas of attitude determination and image processing has yielded a new application of photographic projection. By replacing analog video with spatially aware high-resolution images, the present MAV handheld ground control stations (GCS) can be enhanced to reduce the number of functional manpower positions required during operation. Photographs captured by an MAV can be displayed above pre-existing satellite imagery to give an operator a lasting reference to the location of objects in his vicinity. This newly generated model also increases the functionality of micro air vehicles by allowing for target tracking and energy efficient perch and stare capabilities, both essential elements of persistent surveillance.

Goodnight, Ryan David

2009-08-01T23:59:59.000Z

58

Data-driven modeling and simulation framework for material handling systems in coal mines  

Science Conference Proceedings (OSTI)

In coal mining industry, discrete-event simulation has been widely used to support decisions in material handling system (MHS) to achieve premiums on revenues. However, the conventional simulation modeling approach requires extensive expertise of simulation ... Keywords: Coal mining, Data-driven modeling, Decision making, Material handling system

Chao Meng; Sai Srinivas Nageshwaraniyer; Amir Maghsoudi; Young-Jun Son; Sean Dessureault

2013-03-01T23:59:59.000Z

59

Transpired Solar Collector at NREL's Waste Handling Facility Uses Solar Energy to Heat Ventilation Air (Fact Sheet) (Revised), Federal Energy Management Program (FEMP)  

NLE Websites -- All DOE Office Websites (Extended Search)

Highlights Highlights System Size 300 ft 2 transpired solar collector Energy Production About 125 Btu/hr/ft 2 (400 W/m 2 ) of heat delivery under ideal conditions (full sun) Installation Date 1990 Motivation Provide solar-heated ventilation air to offset some of the heating with conventional electric resistance heaters Annual Savings 14,310 kWh (49 million Btu/yr) or about 26% of the energy required to heat the facility's ventilation air System Details Components Black, 300 ft 2 corrugated aluminum transpired solar collector with a porosity of 2%; bypass damper; two-speed 3000 CFM vane axial supply fan; electric duct heater; thermostat controller Storage None Loads 188 million Btu/year (55,038 kWh/year) winter average to heat 1,300 ft 2 Waste Handling Facility

60

Transpired Solar Collector at NREL's Waste Handling Facility Uses Solar Energy to Heat Ventilation Air (Fact Sheet) (Revised), Federal Energy Management Program (FEMP)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Highlights Highlights System Size 300 ft 2 transpired solar collector Energy Production About 125 Btu/hr/ft 2 (400 W/m 2 ) of heat delivery under ideal conditions (full sun) Installation Date 1990 Motivation Provide solar-heated ventilation air to offset some of the heating with conventional electric resistance heaters Annual Savings 14,310 kWh (49 million Btu/yr) or about 26% of the energy required to heat the facility's ventilation air System Details Components Black, 300 ft 2 corrugated aluminum transpired solar collector with a porosity of 2%; bypass damper; two-speed 3000 CFM vane axial supply fan; electric duct heater; thermostat controller Storage None Loads 188 million Btu/year (55,038 kWh/year) winter average to heat 1,300 ft 2 Waste Handling Facility

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Optimization of Trajectories for the Cask and Plug Remote Handling System in Tokamak  

E-Print Network (OSTI)

May 2011 Optimization of Trajectories for the Cask and Plug Remote Handling System in Tokamak Building and Hot Cell Fusion for Energy Grant: F4E-GRT-276-01 (MS-RH) | April.2011-Oct.2011 o Partners| Project IST (F4E ­ ITER) #12;May 2011 Optimization of Trajectories for the Cask and Plug Remote Handling

Ribeiro,Isabel

62

Conceptual study on Flexible Guidance and Docking system for ITER Remote Handling  

E-Print Network (OSTI)

1 Conceptual study on Flexible Guidance and Docking system for ITER Remote Handling Transport Cask divertors and blanket modules from the Tokamak Building to the Hot Cell Building o Addressed topics for ITER Remote Handling Transport Cask o Publications from IST team: · Isabel Ribeiro, Pedro Lima, Pedro

Ribeiro,Isabel

63

Magnus air turbine system  

DOE Patents (OSTI)

A Magnus effect windmill for generating electrical power is disclosed. A large nacelle-hub mounted pivotally (in Azimuth) atop a support tower carries, in the example disclosed, three elongated barrels arranged in a vertical plane and extending symmetrically radially outwardly from the nacelle. The system provides spin energy to the barrels by internal mechanical coupling in the proper sense to cause, in reaction to an incident wind, a rotational torque of a predetermined sense on the hub. The rotating hub carries a set of power take-off rollers which ride on a stationary circular track in the nacelle. Shafts carry the power, given to the rollers by the wind driven hub, to a central collector or accumulator gear assembly whose output is divided to drive the spin mechanism for the Magnus barrels and the main electric generator. A planetary gear assembly is interposed between the collector gears and the spin mechanism functioning as a differential which is also connected to an auxiliary electric motor whereby power to the spin mechanism may selectively be provided by the motor. Generally, the motor provides initial spin to the barrels for start-up after which the motor is braked and the spin mechanism is driven as though by a fixed ratio coupling from the rotor hub. During high wind or other unusual conditions, the auxiliary motor may be unbraked and excess spin power may be used to operate the motor as a generator of additional electrical output. Interposed between the collector gears of the rotating hub and the main electric generator is a novel variable speed drive-fly wheel system which is driven by the variable speed of the wind driven rotor and which, in turn, drives the main electric generator at constant angular speed. Reference is made to the complete specification for disclosure of other novel aspects of the system such as, for example, the aerodynamic and structural aspects of the novel Magnus barrels as well as novel gearing and other power coupling combination apparatus of the invention. A reading of the complete specification is recommended for a full understanding of the principles and features of the disclosed system.

Hanson, Thomas F. (24204 Heritage La., Newhall, CA 91321)

1982-01-01T23:59:59.000Z

64

Improved intake air filtration systems  

SciTech Connect

This report comprises the results of a project sponsored by the Pipeline Research Committee of the American Gas Association (Improved Intake Air Filtration Systems). The quality of the inlet air consumed by pipeline gas turbines plays a significant role in the performance, maintenance, and economy of turbine operations. The airborne contaminants may cause degradation of compressor blades and hot gas path components, primarily by erosion, corrosion, and fouling. Machines in the pipeline fleet have a typical average loss of 3.5% in output, chiefly caused by fouling of the gas turbine compressor. It also showed that: Air contamination could be significantly reduced by the use of more efficient air filtration systems, especially through the reduction of the quantity of smaller particles ingested.'' Filters which incorporated electrostatically charged fibers (achieved through the use of triboelectric [TE] effects) offered the most promising means for developing an improvement over paper media. The purpose of this program was to validate the use of new technology for self-cleaning air inlet filtration on gas turbine pumping applications. An approach utilizing triboelectrification of fabric filters was examined by testing to determine the penetration (efficiency), cleanability, pressure drop vs flow, and dust-holding capacity of seven pairs of filter cartridges: six fabric and one paper.

Lawson, C.C. (Lawson (Calvin C.), North Wildwood, NJ (United States))

1991-09-01T23:59:59.000Z

65

High Level Waste Remote Handling Equipment in the Melter Cave Support Handling System at the Hanford Waste Treatment Plant  

SciTech Connect

Cold war plutonium production led to extensive amounts of radioactive waste stored in tanks at the Department of Energy's (DOE) Hanford site. Bechtel National, Inc. is building the largest nuclear Waste Treatment Plant in the world located at the Department of Energy's Hanford site to immobilize the millions of gallons of radioactive waste. The site comprises five main facilities; Pretreatment, High Level Waste vitrification, Low Active Waste vitrification, an Analytical Lab and the Balance of Facilities. The pretreatment facilities will separate the high and low level waste. The high level waste will then proceed to the HLW facility for vitrification. Vitrification is a process of utilizing a melter to mix molten glass with radioactive waste to form a stable product for storage. The melter cave is designated as the High Level Waste Melter Cave Support Handling System (HSH). There are several key processes that occur in the HSH cell that are necessary for vitrification and include: feed preparation, mixing, pouring, cooling and all maintenance and repair of the process equipment. Due to the cell's high level radiation, remote handling equipment provided by PaR Systems, Inc. is required to install and remove all equipment in the HSH cell. The remote handling crane is composed of a bridge and trolley. The trolley supports a telescoping tube set that rigidly deploys a TR 4350 manipulator arm with seven degrees of freedom. A rotating, extending, and retracting slewing hoist is mounted to the bottom of the trolley and is centered about the telescoping tube set. Both the manipulator and slewer are unique to this cell. The slewer can reach into corners and the manipulator's cross pivoting wrist provides better operational dexterity and camera viewing angles at the end of the arm. Since the crane functions will be operated remotely, the entire cell and crane have been modeled with 3-D software. Model simulations have been used to confirm operational and maintenance functional and timing studies throughout the design process. Since no humans can go in or out of the cell, there are several recovery options that have been designed into the system including jack-down wheels for the bridge and trolley, recovery drums for the manipulator hoist, and a wire rope cable cutter for the slewer jib hoist. If the entire crane fails in cell, the large diameter cable reel that provides power, signal, and control to the crane can be used to retrieve the crane from the cell into the crane maintenance area. (authors)

Bardal, M.A. [PaR Systems, Inc., Shoreview, MN (United States); Darwen, N.J. [Bechtel National, Inc., Richland, WA (United States)

2008-07-01T23:59:59.000Z

66

Welding Robot and Remote Handling System for the Yucca Mountain Waste Package Closure System  

SciTech Connect

In preparation for the license application and construction of a repository for housing the nation's spent nuclear fuel and high-level waste in Yucca Mountain, the Idaho National Laboratory (INL) has been charged with preparing a mock-up of a full-scale prototype system for sealing the waste packages (WP). Three critical pieces of the closure room include two PaR Systems TR4350 Telerobotic Manipulators and a PaR Systems XR100 Remote Handling System (RHS). The TR4350 Manipulators are 6-axis programmable robots that will be used to weld the WP lids and purge port cap as well as conduct nondestructive examinations. The XR100 Remote Handling System is a 4-axis programmable robot that will be used to transport the WP lids and process tools to the WP for operations and remove equipment for maintenance. The welding and RHS robots will be controlled using separate PaR 5/21 CIMROC Controllers capable of complex motion control tasks. A tele-operated PaR 4350 Manipulator will also be provided with the XR100 Remote Handling System. It will be used for maintenance and associated activities within the closure room. (authors)

Barker, M.E.; Holt, T.E.; LaValle, D.R. [PaR Systems, Inc., Shoreview, MN (United States); Pace, D.P.; Croft, K.M.; Shelton-Davis, C.V. [Battelle Energy Alliance, LLC/Idaho National Laboratory, Idaho Falls, ID (United States)

2008-07-01T23:59:59.000Z

67

Dynamical Control in Large-Scale Material Handling Systems through Agent Technology  

Science Conference Proceedings (OSTI)

Delayed arrivals, missing tag codes, flight changes, break-downs, etc. are some of the factors, which make the environment of airport baggage handling systems (BHS) extremely dynamic. Pre-scheduling and optimization is not an option, as identity, destination, ...

Kasper Hallenborg; Yves Demazeau

2006-12-01T23:59:59.000Z

68

DEVELOPMENT OF A TAMPER RESISTANT/INDICATING AEROSOL COLLECTION SYSTEM FOR ENVIRONMENTAL SAMPLING AT BULK HANDLING FACILITIES  

SciTech Connect

Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity to collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI), Office of Nonproliferation and International Security (NIS), National Nuclear Security Administration (NNSA).

Sexton, L.

2012-06-06T23:59:59.000Z

69

Air distribution effectiveness with stratified air distribution systems  

E-Print Network (OSTI)

, Ph.D Qingyan Chen, Ph.D. Student Member ASHRAE Fellow ASHRAE ABSTRACT Stratified air distribution distribution systems has been taken into consideration by the ASHRAE standards through the air distribution effectiveness. For example, Table 6-1 of ANSI/ASHRAE Standard 62.1-2004 (ASHRAE 2004) defines the minimum

Chen, Qingyan "Yan"

70

EBR-II argon cooling system restricted fuel handling I and C upgrade  

SciTech Connect

The instrumentation and control of the Argon Cooling System (ACS) restricted fuel handling control system at Experimental Breeder Reactor II (EBR-II) is being upgraded from a system comprised of many discrete components and controllers to a computerized system with a graphical user interface (GUI). This paper describes the aspects of the upgrade including reasons for the upgrade, the old control system, upgrade goals, design decisions, philosophies and rationale, and the new control system hardware and software.

Start, S.E.; Carlson, R.B.; Gehrman, R.L. [Argonne National Lab., Idaho Falls, ID (United States). Engineering Div.

1995-06-01T23:59:59.000Z

71

Compressed air energy storage system  

DOE Patents (OSTI)

An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

1981-01-01T23:59:59.000Z

72

Air Products Hydrogen Energy Systems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Products Hydrogen Energy Systems Air Products Hydrogen Energy Systems Hydrogen Infrastructure Air Products Hydrogen Energy Systems More Documents & Publications Quadrennial...

73

Remote Shopping Robot System for Fresh Foods Method of handling foods  

E-Print Network (OSTI)

Remote Shopping Robot System for Fresh Foods ­ Method of handling foods ­ Tetsuo TOMIZAWA, Akihisa a mobile manipulator as a teleoperated tool for accessing and manipulating remote objects. A human uses the system to select and buy fresh foods of a super market from a remote location via the Internet. We

Ohya, Akihisa

74

Mercury Handling for the Target System for a Muon Collider  

Science Conference Proceedings (OSTI)

The baseline target concept for a Muon Collider or Neutrino Factory is a free-stream mercury jet being impacted by an 8-GeV proton beam. The target is located within a 20-T magnetic field, which captures the generated pions that are conducted to a downstream decay channel. Both the mercury and the proton beam are introduced at slight downward angles to the magnetic axis. A pool of mercury serves as a receiving reservoir for the mercury and a dump for the unexpended proton beam. The impact energy of the remaining beam and jet are substantial, and it is required that splashes and waves be controlled in order to minimize the potential for interference of pion production at the target. Design issues discussed in this paper include the nozzle, splash mitigation in the mercury pool, the mercury containment vessel, and the mercury recirculation system.

Graves, Van B [ORNL; Mcdonald, K [Princeton University; Kirk, H. [Brookhaven National Laboratory (BNL); Weggel, Robert [Particle Beam Laser, Inc.; Souchlas, Nicholas [Particle Beam Laser, Inc.; Sayed, H [Brookhaven National Laboratory (BNL); Ding, X [University of California, Los Angeles

2012-01-01T23:59:59.000Z

75

Industrial Compressed Air System Energy Efficiency Guidebook.  

DOE Green Energy (OSTI)

Energy efficient design, operation and maintenance of compressed air systems in industrial plants can provide substantial reductions in electric power and other operational costs. This guidebook will help identify cost effective, energy efficiency opportunities in compressed air system design, re-design, operation and maintenance. The guidebook provides: (1) a broad overview of industrial compressed air systems, (2) methods for estimating compressed air consumption and projected air savings, (3) a description of applicable, generic energy conservation measures, and, (4) a review of some compressed air system demonstration projects that have taken place over the last two years. The primary audience for this guidebook includes plant maintenance supervisors, plant engineers, plant managers and others interested in energy management of industrial compressed air systems.

United States. Bonneville Power Administration.

1993-12-01T23:59:59.000Z

76

Analysis of a Dedicated Outdoor Air System and Low Temperature Supply Air Conditioning System  

E-Print Network (OSTI)

This paper presents the principles and the characteristics of a dedicated outdoor air system (DOAS) and low temperature supply air system. DOAS is offered based on the demands of indoor air quality and the low temperature supply air system is offered based on the demands of saving energy. The two systems are very similar, which is analyzed in this paper. Using actual engineering, we compute the air flow rate, cold load and energy consumption in detail, and provide some good conclusions.

Guang, L.; Li, R.

2006-01-01T23:59:59.000Z

77

Remote Handled Transuranic Sludge Retrieval Transfer And Storage System At Hanford  

SciTech Connect

This paper describes the systems developed for processing and interim storage of the sludge managed as remote-handled transuranic (RH-TRU). An experienced, integrated CH2M HILL/AFS team was formed to design and build systems to retrieve, interim store, and treat for disposal the K West Basin sludge, namely the Sludge Treatment Project (STP). A system has been designed and is being constructed for retrieval and interim storage, namely the Engineered Container Retrieval, Transfer and Storage System (ECRTS).

Raymond, Rick E. [CH2M HILL Plateau Remediation Company, Richland, WA (United States); Frederickson, James R. [AREVA, Avignon (France); Criddle, James [AREVA, Avignon (France); Hamilton, Dennis [CH2M HILL Plateau Remediation Company, Richland, WA (United States); Johnson, Mike W. [CH2M HILL Plateau Remediation Company, Richland, WA (United States)

2012-10-18T23:59:59.000Z

78

Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer  

DOE Patents (OSTI)

This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.

Chastgner, P.

1991-05-08T23:59:59.000Z

79

Remote Handling Equipment for a High-Level Waste Waste Package Closure System  

SciTech Connect

High-level waste will be placed in sealed waste packages inside a shielded closure cell. The Idaho National Laboratory (INL) has designed a system for closing the waste packages including all cell interior equipment and support systems. This paper discusses the material handling aspects of the equipment used and operations that will take place as part of the waste package closure operations. Prior to construction, the cell and support system will be assembled in a full-scale mockup at INL.

Kevin M. Croft; Scott M. Allen; Mark W. Borland

2006-04-01T23:59:59.000Z

80

Packaged air cleaning systems tame desert dust storms in Oman  

SciTech Connect

Vast storms created when cold, northwesterly air masses slam into hot, southwesterly monsoons, moving lethargically over the Sudan and Red Sea, generate swift downdrafts that strike the ground and deflect forward in a powerful, swirling air stream up to 500 km long. As the wind moves along the ground, it churns up particles ranging in size from 80 to 2000 micrometers. This churning also kicks up particles in the 0.1 to 80 micrometer range, and these may rise to heights of 500 m or more, the smaller of which remain suspended for hours. These conditions made it imperative to protect the blades and internal mechanisms of the gas turbines in use at Yibal, Sultanate of Oman. Each of the gas turbines is equipped with a packaged intake air cleaning system. Because no single air filter has been designed to handle effectively the extremely high concentrations of particulates encountered during storms, the AAF air filters are multistage filtration systems. These systems are discussed.

1980-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

The Dynamics of Air Transportation System Transition  

E-Print Network (OSTI)

Both U.S. and European Air Transportation Systems face substantial challenges in transforming to meet future demand. This paper uses a feedback model to identify

Mozdzanowska, Aleksandra

82

Advanced Manufacturing Office: Compressed Air Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

training and other resources Training Calendar Events Calendar Tools Tools to Assess Your Energy System AIRMaster+ Tool Scorecards and Simple Calculators Compressed Air Scorecard...

83

TITLE III EVALUATION REPORT FOR THE MATERIAL AND PERSONNEL HANDLING SYSTEM  

Science Conference Proceedings (OSTI)

This Title III Evaluation Report (TER) provides the results of an evaluation that was conducted on the Material and Personnel Handling System. This TER has been written in accordance with the ''Technical Document Preparation Plan for the Mined Geologic Disposal System Title III Evaluation Reports'' (BA0000000-01717-4600-00005 REV 03). The objective of this evaluation is to provide recommendations to ensure consistency between the technical baseline requirements, baseline design, and the as-constructed Material and Personnel Handling System. Recommendations for resolving discrepancies between the as-constructed system, the technical baseline requirements, and the baseline design are included in this report. Cost and Schedule estimates are provided for all recommended modifications.

T. A. Misiak

1998-05-21T23:59:59.000Z

84

Interface between the SAM data handling system and CDF experiment V. Bartsch 1 , A. Baranovski 2 , D. Benjamin 3 , K. Genser 2 , S. Hsu 3 ,  

E-Print Network (OSTI)

data handling because files which are already present at remote sites are analysed first. This howeverInterface between the SAM data handling system and CDF experiment software V. Bartsch 1 , A at Fermilab has recently changed its data handling system. The old data handling system called DFC (Data File

85

Robust telerobotics - an integrated system for waste handling, characterization and sorting  

Science Conference Proceedings (OSTI)

The Mixed Waste Management Facility (MWMF) at the Lawrence Livermore National Laboratory was designed to serve as a national testbed to demonstrate integrated technologies for the treatment of low-level organic mixed waste at a pilot-plant scale. Pilot-scale demonstration serves to bridge the gap between mature, bench-scale proven technologies and full-scale treatment facilities by providing the infrastructure needed to evaluate technologies in an integrated, front-end to back-end facility. Consistent with the intent to focus on technologies that are ready for pilot scale deployment, the front-end handling and feed preparation of incoming waste material has been designed to demonstrate the application of emerging robotic and remotely operated handling systems. The selection of telerobotics for remote handling in MWMF was made based on a number of factors - personnel protection, waste generation, maturity, cost, flexibility and extendibility. Telerobotics, or shared control of a manipulator by an operator and a computer, provides the flexibility needed to vary the amount of automation or operator intervention according to task complexity. As part of the telerobotics design effort, the technical risk of deploying the technology was reduced through focused developments and demonstrations. The work involved integrating key tools (1) to make a robust telerobotic system that operates at speeds and reliability levels acceptable to waste handling operators and, (2) to demonstrate an efficient operator interface that minimizes the amount of special training and skills needed by the operator. This paper describes the design and operation of the prototype telerobotic waste handling and sorting system that was developed for MWMF.

Couture, S.A.; Hurd, R.L.; Wilhelmsen, K.C.

1997-01-01T23:59:59.000Z

86

Rooftop Unitary Air Conditioner with Integral Dedicated Outdoor Air System  

SciTech Connect

Energy use of rooftop and other unitary air-conditioners in commercial applications accounts for about 1 quad (10{sup 15} Btu) of primary energy use annually in the U.S. [Reference 7]. The realization that this cooling equipment accounts for the majority of commercial building cooled floorspace and the majority also of commercial building energy use has spurred development of improved-efficiency equipment as well as development of stricter standards addressing efficiency levels. Another key market driver affecting design of rooftop air-conditioning equipment has been concern regarding comfort and the control of humidity. Trends for increases in outdoor air ventilation rates in certain applications, and the increasing concern about indoor air quality problems associated with humidity levels and moisture in buildings points to a need for improved dehumidification capability in air-conditioning equipment of all types. In many cases addressing this issue exacerbates energy efficiency, and vice versa. The integrated dedicated outdoor air system configuration developed in this project addresses both energy and comfort/humidity issues.

Tiax Llc

2006-02-28T23:59:59.000Z

87

Technology gap analysis on sodium-cooled reactor fuel handling system supporting advanced burner reactor development.  

Science Conference Proceedings (OSTI)

The goals of the Global Nuclear Energy Partnership (GNEP) are to expand the use of nuclear energy to meet increasing global energy demand in an environmentally sustainable manner, to address nuclear waste management issues without making separated plutonium, and to address nonproliferation concerns. The advanced burner reactor (ABR) is a fast reactor concept which supports the GNEP fuel cycle system. Since the integral fast reactor (IFR) and advanced liquid-metal reactor (ALMR) projects were terminated in 1994, there has been no major development on sodium-cooled fast reactors in the United States. Therefore, in support of the GNEP fast reactor program, the history of sodium-cooled reactor development was reviewed to support the initiation of this technology within the United States and to gain an understanding of the technology gaps that may still remain for sodium fast reactor technology. The fuel-handling system is a key element of any fast reactor design. The major functions of this system are to receive, test, store, and then load fresh fuel into the core; unload from the core; then clean, test, store, and ship spent fuel. Major requirements are that the system must be reliable and relatively easy to maintain. In addition, the system should be designed so that it does not adversely impact plant economics from the viewpoints of capital investment or plant operations. In this gap analysis, information on fuel-handling operating experiences in the following reactor plants was carefully reviewed: EBR-I, SRE, HNPF, Fermi, SEFOR, FFTF, CRBR, EBR-II, DFR, PFR, Rapsodie, Phenix, Superphenix, KNK, SNR-300, Joyo, and Monju. The results of this evaluation indicate that a standardized fuel-handling system for a commercial fast reactor is yet to be established. However, in the past sodium-cooled reactor plants, most major fuel-handling components-such as the rotatable plug, in-vessel fuel-handling machine, ex-vessel fuel transportation cask, ex-vessel sodium-cooled storage, and cleaning stations-have accumulated satisfactory construction and operation experiences. In addition, two special issues for future development are described in this report: large capacity interim storage and transuranic-bearing fuel handling.

Chikazawa, Y.; Farmer, M.; Grandy, C.; Nuclear Engineering Division

2009-03-01T23:59:59.000Z

88

Estimation of tritium and helium inventory in the tritium handling system in Korea  

Science Conference Proceedings (OSTI)

In Korea, the Wolsong Tritium Removal Facility (WTRF) is under construction to reduce the amount of tritium present in the moderator and coolant of the CANDU type Wolsong nuclear power plants. Recently, a study on the tritium handling system for recovery of the tritium collected from the WTRF was started. Some tritium would enter the steel of the container walls and subsequently decay to helium. This helium can deteriorate the mechanical properties of the material of the tritium handling system. To evaluate the tritium and helium inventory in the stainless steel wall of this system, the time-dependent diffusion equation was developed, solved and the results are presented in this paper. These results were compared to previous work that evaluated the tritium inventory in the stainless steel wall of 50-L tritium containers. Tritium and helium concentration profiles and the corresponding inventories were evaluated with respect to the various parameters such as exposure time, temperature, and partial pressure. After 24 years, the helium inventory in the wall of the tritium handling system exceeds the tritium inventory. (authors)

Yook, D.; Lee, S.; Lee, K. [Dept. of Nuclear Eng., KAIST, 373-1, Kusong-dong, Yusong-gu, Daejon 305-701 (Korea, Republic of); Song, K. M.; Shon, S. H. [KEPRI, 103-16 Munji-Dong, Yuseong-Gu, Daejeon, 305-380 (Korea, Republic of)

2008-07-15T23:59:59.000Z

89

Troubleshooting the residential air conditioning system  

Science Conference Proceedings (OSTI)

In order to effectively diagnose problems in a residential air conditioning system, the technician should develop and follow a logical step-by-step troubleshooting procedure. A list of problems, along with possible causes and solutions, that a technician may encounter when servicing a residential air conditioner is presented.

Puzio, H. [Sussex County Vocational Technical School, Sparta, NJ (United States)

1996-01-01T23:59:59.000Z

90

Interim report spent nuclear fuel retrieval system fuel handling development testing  

Science Conference Proceedings (OSTI)

Fuel handling development testing was performed in support of the Fuel Retrieval System (FRS) Sub-Project at the Hanford Site. The project will retrieve spent nuclear fuel, clean and remove fuel from canisters, repackage fuel into baskets, and load fuel into a multi-canister overpack (MCO) for vacuum drying and interim dry storage. The FRS is required to retrieve basin fuel canisters, clean fuel elements sufficiently of uranium corrosion products (or sludge), empty fuel from canisters, sort debris and scrap from whole elements, and repackage fuel in baskets in preparation for MCO loading. The purpose of fuel handling development testing was to examine the systems ability to accomplish mission activities, optimization of equipment layouts for initial process definition, identification of special needs/tools, verification of required design changes to support performance specification development, and validation of estimated activity times/throughput. The test program was set up to accomplish this purpose through cold development testing using simulated and prototype equipment; cold demonstration testing using vendor expertise and systems; and graphical computer modeling to confirm feasibility and throughput. To test the fuel handling process, a test mockup that represented the process table was fabricated and installed. The test mockup included a Schilling HV series manipulator that was prototypic of the Schilling Hydra manipulator. The process table mockup included the tipping station, sorting area, disassembly and inspection zones, fuel staging areas, and basket loading stations. The test results clearly indicate that the Schilling Hydra arm cannot effectively perform the fuel handling tasks required unless it is attached to some device that can impart vertical translation, azimuth rotation, and X-Y translation. Other test results indicate the importance of camera locations and capabilities, and of the jaw and end effector tool design. 5 refs., 35 figs., 3 tabs.

Ketner, G.L.; Meeuwsen, P.V.; Potter, J.D.; Smalley, J.T.; Baker, C.P.; Jaquish, W.R.

1997-06-01T23:59:59.000Z

91

Handling Pyrophoric Reagents  

SciTech Connect

Pyrophoric reagents are extremely hazardous. Special handling techniques are required to prevent contact with air and the resulting fire. This document provides several methods for working with pyrophoric reagents outside of an inert atmosphere.

Alnajjar, Mikhail S.; Haynie, Todd O.

2009-08-14T23:59:59.000Z

92

Energy Efficiency in Compressed Air Systems  

E-Print Network (OSTI)

Energy use in compressed air systems accounts for typically 10% of the total industrial electricity consumption. It also accounts for close to 99% of the CO2 footprint of an air compressor and approximately 80% of the life cycle costs of a compressor, over its lifetime. Considering these facts, it is sometimes surprising to see the lack of attention to compressed air systems in industry. This paper attempts to create awareness as to how a great deal of energy can be saved through a conscious process of selection and use of compressed air systems, bringing substantial benefits in economics and the environment. It also attempts to highlight the relative importance of energy savings over the costs of investments made in energy saving features and processes.

Hingorani, A.; Pavlov, A.

2010-01-01T23:59:59.000Z

93

Numerical Analysis of a Cold Air Distribution System  

E-Print Network (OSTI)

Cold air distribution systems may reduce the operating energy consumption of air-conditioned air supply system and improve the outside air volume percentages and indoor air quality. However, indoor temperature patterns and velocity field are easily non-uniform so that residents usually feel uncomfortable. The distribution of indoor airflow by cold air distribution is researched in this paper. We study indoor air distribution under different low temperature air supply conditions by numerical simulation. The simulated results agree well with the experiments.

Zhu, L.; Li, R.; Yuan, D.

2006-01-01T23:59:59.000Z

94

A Sentinel Approach to Fault Handling in Multi-Agent Systems  

E-Print Network (OSTI)

Fault handling in Multi-Agent Systems (MAS) is not much addressed in current research. Normally, it is considered difficult to address in detail and often well covered by traditional methods, relying on the underlying communication and operating system. In this paper it is shown that this is not necessarily true, at least not with the assumptions on applications we have made. These assumptions are a massive distribution of computing components, a heterogeneous underlying infrastructure (in terms of hardware, software and communication methods), an emerging configuration, possibly different parties in control of sub-systems, and real-time demands in parts of the system. The key problem is that while a MAS is modular and therefore should be a good platform for building fault tolerant systems, it is also non-deterministic, making it difficult to guarantee a specific behaviour, especially in fault situations. Our proposal is to introduce sentinels to guard certain functionality and to pro...

Staffan Hgg Department; Staffan Hägg

1996-01-01T23:59:59.000Z

95

Energy efficiency improvements in Chinese compressed air systems  

E-Print Network (OSTI)

air system assessments and energy audits based on a systemaudit. These compressed air system assessments may be conducted by compressor manufacturers/distributors or energy

McKane, Aimee; Li, Li; Li, Yuqi; Taranto, T.

2008-01-01T23:59:59.000Z

96

Air Products Hydrogen Energy Systems  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Kiczek,Edward F. [KICZEKEF@airproducts.com] Kiczek,Edward F. [KICZEKEF@airproducts.com] Sent: Monday, April 18, 2011 7:40 PM To: Gopstein, Avi (S4) Subject: Hydrogen Infrastructure Latest Advancements Attachments: Air Products Written Comments to 2011 2012 AB118 Investment Plan.pdf Follow Up Flag: Follow up Flag Status: Flagged Categories: QTR Transparency Avi, You may recall we met in DC when the McKinsey team from Germany came to discuss the EU study on hydrogen infrastructure. At that time I mention a significant advance in infrastructure that would be announced soon. Attached is our testimony to the California Energy Commission on deploying that technology. We were awarded the project to build 9 stations in southern California with the backing of

97

End-To-End Request Handling In Distributed Video-On-Demand Systems  

E-Print Network (OSTI)

In this paper we provide an end-to-end analysis of a distributed Video-on-Demand system consisting of a hierarchy of server clusters and networks. We develop an analytical framework for remote service by combining two critical subsystems, the storage and the network subsystems. We use this framework to analyze different request handling policies that maximize throughput. We show that the results of our end-to-end analysis are scalable and may be used to predict system performance when the demand changes and the system size is scaled up. The relative performance order of different request handling policies remains the same, with the policy that uses retrials at more than one resource exhibiting better performance than other policies. Keywords: Network and Resource Management, Distributed VoD. 1 INTRODUCTION The focus of this paper is to conduct an end-to-end analysis that provides insight into efficient operation of a hierarchical Video-on-Demand (VoD) system. Two issues dealt in this...

Padmavathi Mundur; Robert Simon; Arun Sood

1999-01-01T23:59:59.000Z

98

Safety System Oversight Assessment of the Los Alamos National Laboratory Weapons Engineering Tritium Facility Tritium Gas Handling System  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Site Visit Report Site Visit Report Safety System Oversight Assessment of the Los Alamos National Laboratory Weapons Engineering Tritium Facility Tritium Gas Handling System INTRODUCTION AND OVERVIEW This report documents the results of the Office of Health, Safety and Security's (HSS) review of a safety system oversight (SSO) assessment of the Los Alamos National Laboratory (LANL) Weapons Engineering Tritium Facility (WETF) tritium gas handling system (TGHS). The assessment evaluated the TGHS's ability to perform as required by safety bases and other applicable requirements. The assessment was sponsored by the U.S. Department of Energy (DOE) Los Alamos Site Office (LASO) and was conducted October 25 - November 5, 2010. LASO was the overall lead organization for the evaluation, which included independent

99

Advanced Overfire Air system and design  

DOE Green Energy (OSTI)

The objective of the proposed project is to design, install and optimize a prototype advanced tangential OFA air system on two mass feed stoker boilers that can burn coal, biomass and a mixture of these fuels. The results will be used to develop a generalized methodology for retrofit designs and optimization of advanced OFA air systems. The advanced OFA system will reduce particulate and NOx emissions and improve overall efficiency by reducing carbon in the ash and excess oxygen. The advanced OFA will also provide capabilities for carrying full load and improved load following and transitional operations.

Gene berkau

2004-07-30T23:59:59.000Z

100

Improving Energy Efficiency of Compressed Air System Based on System Audit  

E-Print Network (OSTI)

can cover the maximum system demand. The similar successfulsized to meet the maximum plant air demand. Few air systems

Shanghai, Hongbo Qin; McKane, Aimee

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Room Temperature Control During Season Switchover with Single Duct Variable Air Volume System Without Reheat  

E-Print Network (OSTI)

The Langford “A” building houses the College of Architecture on TAMU campus. There are ten singleduct variable air volume (VAV) air-handling units (AHUs) without reheat serving the building. The local pneumatic thermostats modulate the dampers of VAV boxes to maintain room temperature at their setpoints. The thermostat action is switched from direct acting (DA) to reverse acting (RA) when the season changes from fall to winter and vice versa from winter to spring, based on the out side air temperature, when season changes. This results in various parts of the building ether too cold or too hot during the season change. This paper presents that the thermostat action will be switched according to cooling loads or discharge air temperature, instead of outside air temperature. For the interior zone, thermostat action does not need to be switched at all. The comfort is improved and savings is achieved by the new control scheme. Because some air-handling units (AHUs) serve both interior and exterior zones, this system never worked as intended. The system must be modified to have zone reheat and the AHUs discharge air temperature is set below dew point for humidity control.

Liu, C.; Deng, S.; Claridge, D. E.; Turner, W. D.; Bruner, H.

2003-01-01T23:59:59.000Z

102

Improving Energy Efficiency of Compressed Air System Based on System Audit  

E-Print Network (OSTI)

50 compressed air system energy audits completed by Shanghai50 compressed air system energy audits completed by Shanghaiof compressed air energy audits conducted by the Shanghai

Shanghai, Hongbo Qin; McKane, Aimee

2008-01-01T23:59:59.000Z

103

A Globally Distributed System for Job, Data, and Information Handling for High Energy Physics  

SciTech Connect

The computing infrastructures of the modern high energy physics experiments need to address an unprecedented set of requirements. The collaborations consist of hundreds of members from dozens of institutions around the world and the computing power necessary to analyze the data produced surpasses already the capabilities of any single computing center. A software infrastructure capable of seamlessly integrating dozens of computing centers around the world, enabling computing for a large and dynamical group of users, is of fundamental importance for the production of scientific results. Such a computing infrastructure is called a computational grid. The SAM-Grid offers a solution to these problems for CDF and DZero, two of the largest high energy physics experiments in the world, running at Fermilab. The SAM-Grid integrates standard grid middleware, such as Condor-G and the Globus Toolkit, with software developed at Fermilab, organizing the system in three major components: data handling, job handling, and information management. This dissertation presents the challenges and the solutions provided in such a computing infrastructure.

Garzoglio, Gabriele; /DePaul U.

2005-12-01T23:59:59.000Z

104

Optimal control of a bleed air temperature regulation system.  

E-Print Network (OSTI)

??This thesis investigates temperature control of an aircraft engine bleed air system, aiming at reducing ram air usage to reduce fuel consumption while maintaining fast… (more)

Shang, Lan

2007-01-01T23:59:59.000Z

105

CFD Simulation and Analysis of the Combined Evaporative Cooling and Radiant Ceiling Air-conditioning System  

E-Print Network (OSTI)

Due to such disadvantages as large air duct and high energy consumption of the current all- outdoor air evaporative cooling systems used in the dry region of Northwest China, as well as the superiority of the ceiling cooling system in improving thermal comfort and saving energy, a combined system is presented in this paper. It combines an evaporative cooling system with ceiling cooling, in which the evaporative cooling system handles the entire latent load and one part of the sensible loads, and the ceiling cooling system deals with the other part of sensible loads in the air-conditioned zone, so that the condensation on radiant panels and the insufficiency of cooling capacity can be avoided. The cooling water at 18? used in the cooling coils of ceiling cooling system can be ground water, tap water or the cooled water from cooling towers in the summer. This new air-conditioning system and existing all- outdoor air evaporative cooling system are applied to a project in the city of Lanzhou. Energy consumption analysis of the building is carried out using the energy consumption code. Velocity and temperature distribution in the air-conditioned zone is computed using CFD. According to the results, the energy consumption and indoor human thermal comfort of both systems are then compared. It is concluded that the new system occupies less building space, reduces energy consumption, improves indoor human thermal comfort and saves initial investment.

Xiang, H.; Yinming, L.; Junmei, W.

2006-01-01T23:59:59.000Z

106

Forced Air Systems in High Performance Homes  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

FORCED AIR SYSTEMS IN FORCED AIR SYSTEMS IN HIGH PERFORMANCE HOMES Iain Walker (LBNL) Building America Meeting 2013 What are the issues? 1. Sizing  When is too small too small? 2. Distribution  Can we get good mixing at low flow? 3. Performance  Humidity Control  Part load efficiency  Blowers & thermal losses Sizing  Part-load - not an issue with modern equipment  Careful about predicted loads - a small error becomes a big problem for tightly sized systems  Too Low Capacity = not robust  Extreme vs. design days  Change in occupancy  Party mode  Recovery from setback Sizing  Conventional wisdom - a good envelope = easy to predict and not sensitive to indoor conditions  But..... Heating and cooling become discretionary - large variability depending on occupants

107

Design and realization of a microfluidic system for dielectrophoretic colloidal handling  

Science Conference Proceedings (OSTI)

Precise spatial localization of colloids is required to fully exploit the potential of colloidal handling in a microfluidic channel. In this work, we present the fabrication and integration of a new type of microfluidic chip that can provide such tools. ... Keywords: Colloidal handling, Dielectrophoresis, Microfluidics, Photopatternable silicones

T. Honegger; K. Berton; T. Pinedo-Rivera; D. Peyrade

2009-04-01T23:59:59.000Z

108

Neural network control for an intelligent air handler in an air-conditioning system.  

E-Print Network (OSTI)

??Many commercial air-conditioning systems in hot and humid areas like Singapore are operated throughout the year. There are two main classifications for these systems: the… (more)

Zhang, Qi.

2008-01-01T23:59:59.000Z

109

Criticality Safety Evaluation Report for the Cold Vacuum Drying (CVD) Facilities Process Water Handling System  

SciTech Connect

This report addresses the criticality concerns associated with process water handling in the Cold Vacuum Drying Facility. The controls and limitations on equipment design and operations to control potential criticality occurrences are identified.

KESSLER, S.F.

2000-08-10T23:59:59.000Z

110

Indoor Air Quality Impacts of Residential HVAC Systems ...  

Science Conference Proceedings (OSTI)

Page 1. NISTIR 5559 Indoor Air Quality Impacts of Residential HVAC Systems Phase 11.AReport: Baseline and Preliminary Simulations ...

1997-09-03T23:59:59.000Z

111

Proposal for Construction/Demonstration/Implementation of A Material Handling System  

SciTech Connect

Vortec Corporation, the United States Enrichment Corporation (USEC) and DOE/Paducah propose to complete the technology demonstration and the implementation of the Material Handling System developed under Contract Number DE-AC21-92MC29120. The demonstration testing and operational implementation will be done at the Paducah Gaseous Diffusion Plant. The scope of work, schedule and cost for the activities are included in this proposal. A description of the facility to be constructed and tested is provided in Exhibit 1, attached. The USEC proposal for implementation at Paducah is presented in Exhibit 2, and the commitment letters from the site are included in Exhibit 3. Under our agreements with USEC, Bechtel Jacobs Corporation and DOE/Paducah, Vortec will be responsible for the construction of the demonstration facility as documented in the engineering design package submitted under Phase 4 of this contract on August 9, 2001. USEC will have responsibility for the demonstration testing and commercial implementation of the plant. The demonstration testing and initial commercial implementation of the technology will be achieved by means of a USEC work authorization task with the Bechtel Jacobs Corporation. The initial processing activities will include the processing of approximately 4,250 drums of LLW. Subsequent processing of LLW and TSCA/LLW will be done under a separate contract or work authorization task. To meet the schedule for commercial implementation, it is important that the execution of the Phase 4 project option for construction of the demonstration system be executed as soon as possible. The schedule we have presented herein assumes initiation of the construction phase by the end of September 2001. Vortec proposes to complete construction of the demonstration test system for an estimated cost of $3,254,422. This price is based on the design submitted to DOE/NETL under the Phase 4 engineering design deliverable (9 august 2001). The cost is subject to the assumptions and conditions identified in Section 6 of this proposal.

Jim Jnatt

2001-08-24T23:59:59.000Z

112

Project Plan 7930 Cell G PaR Remote Handling System Replacement  

Science Conference Proceedings (OSTI)

For over 40 years the US Department of Energy (DOE) and its predecessors have made Californium-252 ({sup 252}Cf) available for a wide range of industries including medical, nuclear fuels, mining, military and national security. The Radiochemical Engineering Development Center (REDC) located within the Oak Ridge National Laboratory (ORNL) processes irradiated production targets from the High Flux Isotope Reactor (HFIR). Operations in Building 7930, Cell G provide over 70% of the world's demand for {sup 252}Cf. Building 7930 was constructed and equipped in the mid-1960s. Current operations for {sup 252}Cf processing in Building 7930, Cell G require use of through-the-wall manipulators and the PaR Remote Handling System. Maintenance and repairs for the manipulators is readily accomplished by removal of the manipulator and relocation to a repair shop where hands-on work can be performed in glove boxes. Contamination inside cell G does not currently allow manned entry and no provisions were created for a maintenance area inside the cell. There has been no maintenance of the PaR system or upgrades, leaving operations vulnerable should the system have a catastrophic failure. The Cell G PaR system is currently being operated in a run to failure mode. As the manipulator is now 40+ years old there is significant risk in this method of operation. In 2006 an assessment was completed that resulted in recommendations for replacing the manipulator operator control and power centers which are used to control and power the PaR manipulator in Cell G. In mid-2008 the chain for the bridge drive failed and subsequent examinations indicated several damaged links (see Figure 1). To continue operations the PaR manipulator arm is being used to push and pull the bridge as a workaround. A retrieval tool was fabricated, tested and staged inside Cell G that will allow positioning of the bridge and manipulator arm for removal from the cell should the PaR system completely fail. A fully functioning and reliable Par manipulator arm is necessary for uninterrupted {sup 252}Cf operations; a fully-functioning bridge is needed for the system to function as intended.

Kinney, Kathryn A [ORNL

2009-10-01T23:59:59.000Z

113

Modeling and construction of a computer controlled air conditioning system.  

E-Print Network (OSTI)

??As energy efficient devices become more necessary, it is desired to increase the efficiency of air conditioning systems. Current systems use on/off control, where the… (more)

Frink, Brandon S.

2007-01-01T23:59:59.000Z

114

Integrated Ice Storage/Sprinkler HVAC System Sharply Cuts Energy Costs and Air-Distribution First Costs  

E-Print Network (OSTI)

Integrated ice thermal storage/sprinkler HVAC systems developed and applied by the author in several commercial applications shift a major portion of electric utility demand to cheaper off-peak hours, while also reducing significantly the first cost of distribution ductwork. Savings of up to 80% in primary duct and air handler costs (compared to a traditional all-air HVAC system) partially offset the first cost of ice storage equipment, which in turn permits a 50% reduction in utility energy costs for air conditioning in some facilities. The basic ice storage/sprinkler HVAC system is described as well as optional subsystems, such as cogeneration, that are cost-effective under certain conditions. The system's design parameters, psychrometric process, and thermodynamic characteristics are presented and two installations are described, a 223,000-sq ft shopping center and a 150,000-sq ft, two-story retail store. Reductions in the size and first cost of primary air-handling equipment and ductwork are achieved by distributing a small quantity (0.1 to 0.2 cfm/sq ft) of very dry, 40°F primary air. All dehumidification is handled by the ice-chilled primary air, which is distributed in variable, volume, determined by the space dehumidification requirement, to fan-coil induction terminal units. The primary air is mixed with fan-induced room air in the terminals prior to distribution to the space at a constant volume. The fan-induction terminals contain cooling coils connected to the integrated sprinkler system, which circulates chilled water from the central plant through the coils when additional sensible cooling is required. This chilled water is at a thermodynamically efficient elevated temperature (58-68°F), since it handles sensible cooling load only.

Meckler, G.

1986-01-01T23:59:59.000Z

115

Solar air heating system for combined DHW and space heating  

E-Print Network (OSTI)

Solar air heating system for combined DHW and space heating solar air collector PV-panel fannon-return valve DHW tank mantle cold waterhot water roof Solar Energy Centre Denmark Danish Technological Institute SEC-R-29 #12;Solar air heating system for combined DHW and space heating Søren �stergaard Jensen

116

The Feasibility Analysis of a New Air-Conditioning System  

Science Conference Proceedings (OSTI)

This paper presents a new modular solar refrigeration and liquid desiccant air conditioning system composed by adsorption refrigeration system, liquid desiccant system and roof cold radiation. The feasibility and beneficial of this new system are analyzed ... Keywords: liquid desiccant, modular solar refrigeration, new air conditioning system, roof cold radiation, technical and economic feasibility analysis

Jinggang Wang; Meixia Du; Xiaoxia Gao; Jin Zhao; Zhenjiang Yin; Yi Man

2009-12-01T23:59:59.000Z

117

Residential Forced Air System Cabinet Leakage and Blower Performance  

NLE Websites -- All DOE Office Websites (Extended Search)

Residential Forced Air System Cabinet Leakage and Blower Performance Residential Forced Air System Cabinet Leakage and Blower Performance Title Residential Forced Air System Cabinet Leakage and Blower Performance Publication Type Report LBNL Report Number LBNL-3383E Year of Publication 2010 Authors Walker, Iain S., Darryl J. Dickerhoff, and William W. Delp Publisher Lawrence Berkeley National Laboratory City Berkeley Keywords air flow measurement, air leakage, blower power measurement, blowers, energy performance of buildings group, forced air systems, furnaces, indoor environment department, other, public interest energy research (pier) program, residential hvac Abstract This project evaluated the air leakage and electric power consumption of Residential HVAC components, with a particular focus on air leakage of furnace cabinets. Laboratory testing of HVAC components indicated that air leakage can be significant and highly variable from unit to unit - indicating the need for a standard test method and specifying maximum allowable air leakage in California State energy codes. To further this effort, this project provided technical assistance for the development of a national standard for Residential HVAC equipment air leakage. This standard is being developed by ASHRAE and is called "ASHRAE Standard 193P - Method of test for Determining the Air Leakage Rate of HVAC Equipment". The final part of this project evaluated techniques for measurement of furnace blower power consumption. A draft test procedure for power consumption was developed in collaboration with the Canadian General Standards Board: CSA 823 "Performance Standard for air handlers in residential space conditioning systems".

118

Subsonic Tests of a Flush Air Data Sensing System Applied to a Fixed-Wing Micro Air Vehicle  

Science Conference Proceedings (OSTI)

Flush air data sensing (FADS) systems have been successfully tested on the nose tip of large manned/unmanned air vehicles. In this paper we investigate the application of a FADS system on the wing leading edge of a micro (unmanned) air vehicle (MAV) ... Keywords: Extended minimum resource allocating neural networks, Fault accommodation, Flush air data sensing systems, Micro (unmanned) air vehicle

Ihab Samy; Ian Postlethwaite; Dawei Gu

2009-03-01T23:59:59.000Z

119

Transportation and handling environment  

SciTech Connect

The elements of the environment relating to transportation and handling include temperature, solar radiation, precipitation, humidity, pressure, shock, and vibration. While each of these deserves consideration, the latter two, shock and vibration, are perhaps the least understood. The report discusses all of these elements, but concentrates largely on shock and vibration. Emphasis is upon the necessity of understanding both the product and the environment. To that end, descriptions of the environment which have been derived statistically are discussed. Land, sea, and air transport are considered. Current knowledge of the handling environment is indicated.

Gens, M.B.

1972-09-01T23:59:59.000Z

120

Control Humidity With Single-Duct, Single-Zone, Constant Air Volume System  

E-Print Network (OSTI)

The lecture hall of the Richardson Petroleum Building at Texas A&M University is a large lecture hall, with a total floor area of approximately 2500 ft^2. The lecture hall was served by a constant air volume (CAV) air handling unit (AHU) which had no reheat coil. This resulted in high room humidity levels although the room temperature was satisfied for part load conditions, especially when there was very little sensible load from the room. This paper presents Continuous Commissioning efforts (CC), which turned this inefficient, humid lecture hall into a comfortable learning environment. This case study also explores other possibilities to solve the humidity control problem with single-duct, single-zone constant air volume systems.

Chen, H.; Deng, S.; Bruner, H. L.; Claridge, D. E.

2000-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Heating, ventilation and air conditioning systems  

DOE Green Energy (OSTI)

A study is made of several outstanding issues concerning the commercial development of environmental control systems for electric vehicles (EVs). Engineering design constraints such as federal regulations and consumer requirements are first identified. Next, heating and cooling loads in a sample automobile are calculated using a computer model available from the literature. The heating and cooling loads are then used as a basis for estimating the electrical consumption that is to be expected for heat pumps installed in EVs. The heat pump performance is evaluated using an automobile heat pump computer model which has been developed recently at Oak Ridge National Laboratory (ORNL). The heat pump design used as input to the model consists of typical finned-tube heat exchangers and a hermetic compressor driven by a variable-speed brushless dc motor. The simulations suggest that to attain reasonable system efficiencies, the interior heat exchangers that are currently installed as automobile air conditioning will need to be enlarged. Regarding the thermal envelope of the automobile itself, calculations are made which show that considerable energy savings will result if steps are taken to reduce {open_quote}hot soak{close_quote} temperatures and if the outdoor air ventilation rate is well controlled. When these changes are made, heating and cooling should consume less than 10% of the total stored electrical energy for steady driving in most U.S. climates. However, this result depends strongly upon the type of driving: The fraction of total power for heating and cooling ({open_quote}range penalty{close_quote}) increases sharply for driving scenarios having low average propulsion power, such as stop-and-go driving.

Kyle, D.M. [Oak Ridge National Lab., TN (United States); Sullivan, R.A. [Dept. of Energy, Washington, DC (United States)

1993-02-01T23:59:59.000Z

122

WEAR RESISTANT ALLOYS FOR COAL HANDLING EQUIPMENT  

E-Print Network (OSTI)

Proceedings of the Conference on Coal Feeding Systems, HeldWear Resistant Alloys for Coal Handling Equipment", proposalWear Resistant Alloys for Coal Handling Equi pment". The

Bhat, M.S.

2011-01-01T23:59:59.000Z

123

December 2005 PREVENTING AND HANDLING  

E-Print Network (OSTI)

, and remote access servers. NIST SP 800-61, Computer Security Incident Handling Guide, describes the fourDecember 2005 PREVENTING AND HANDLING MALWARE INCIDENTS: HOW TO PROTECT INFORMATION TECHNOLOGY SYSTEMS FROM MALICIOUS CODE AND SOFTWARE PREVENTING AND HANDLING MALWARE INCIDENTS: HOW TO PROTECT

124

Using Modelica for Physical Modeling of Air-Conditioning Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Using Modelica for Physical Modeling of Air-Conditioning Systems Using Modelica for Physical Modeling of Air-Conditioning Systems Speaker(s): Jonas Eborn Date: August 23, 2007 - 12:00pm Location: 90-4133 Seminar Host/Point of Contact: Michael Wetter The Air Conditioning library is a commercial Modelica library for the steady-state and transient simulation of air conditioning systems using both compact micro-channel heat exchangers as well as fin-and-tube type heat exchangers. Currently it is mostly used by automotive OEMs and suppliers that need high-accuracy system level models to evaluate energy efficiency of systems developed under the pressure of reduced design cycle times. The library also has applications in other areas, including aircraft cooling systems and residential air-conditioning. The Air Conditioning library contains published correlations for heat and mass transfer and

125

Closed-loop air cooling system for a turbine engine  

DOE Patents (OSTI)

Method and apparatus are disclosed for providing a closed-loop air cooling system for a turbine engine. The method and apparatus provide for bleeding pressurized air from a gas turbine engine compressor for use in cooling the turbine components. The compressed air is cascaded through the various stages of the turbine. At each stage a portion of the compressed air is returned to the compressor where useful work is recovered.

North, William Edward (Winter Springs, FL)

2000-01-01T23:59:59.000Z

126

A new guide for commissioning air handling systems: Using a model functional test  

E-Print Network (OSTI)

or a transmitter at the RTD. Subject to moderate self-temperature detector (RTD) Nearly linear over a wide rangeresistance compared to a RTD, so lead wire resistance errors

Haasl, Tudi; Sellers, David; Friedman, Hannah; Piette, Mary Ann; Bourassa, Norman; Gillespie, Ken

2002-01-01T23:59:59.000Z

127

Energy efficiency improvements in Chinese compressed air systems  

E-Print Network (OSTI)

Air Systems, Paper #071 Energy efficiency improvements into increase industrial energy efficiency. As a result, morein use. Over time, energy efficiency decreases and the cost

McKane, Aimee; Li, Li; Li, Yuqi; Taranto, T.

2008-01-01T23:59:59.000Z

128

Current Research on Building Energy Systems and Air Cleaning...  

NLE Websites -- All DOE Office Websites (Extended Search)

Program Development Contact Us Department Contacts Media Contacts Current Research on Building Energy Systems and Air Cleaning by Visible-Photocatalytic Oxidation (Visible-PCO)...

129

Innovative Systems for Solar Air Conditioning of Buildings  

E-Print Network (OSTI)

Solar air conditioning is an attractive technology to achieve comfortable room conditions, especially in hot and sunny climates. In particular air conditioning systems based on sorption technologies offer several advantages as they can be designed for a high efficient utilization of solar thermal energy. To show the today's and near future potential innovative solar cooling and air conditioning systems are discussed which are well adapted to the utilization of solar energy. The system performance of each air conditioning system is evaluated under Abu Dhabi design conditions.

Kessling, W.; Peltzer, M.

2004-01-01T23:59:59.000Z

130

Using Modelica for Physical Modeling of Air-Conditioning Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

and ready-to-use models for all relevant components of automotive air conditioning systems like condenser, evaporator, compressor, expansion devices and accumulatorreceiver...

131

Using Single-Camera 3-D Imaging to Guide Material Handling Robots in a Nuclear Waste Package Closure System  

SciTech Connect

Nuclear reactors for generating energy and conducting research have been in operation for more than 50 years, and spent nuclear fuel and associated high-level waste have accumulated in temporary storage. Preparing this spent fuel and nuclear waste for safe and permanent storage in a geological repository involves developing a robotic packaging system—a system that can accommodate waste packages of various sizes and high levels of nuclear radiation. During repository operation, commercial and government-owned spent nuclear fuel and high-level waste will be loaded into casks and shipped to the repository, where these materials will be transferred from the casks into a waste package, sealed, and placed into an underground facility. The waste packages range from 12 to 20 feet in height and four and a half to seven feet in diameter. Closure operations include sealing the waste package and all its associated functions, such as welding lids onto the container, filling the inner container with an inert gas, performing nondestructive examinations on welds, and conducting stress mitigation. The Idaho National Laboratory is designing and constructing a prototype Waste Package Closure System (WPCS). Control of the automated material handling is an important part of the overall design. Waste package lids, welding equipment, and other tools must be moved in and around the closure cell during the closure process. These objects are typically moved from tool racks to a specific position on the waste package to perform a specific function. Periodically, these objects are moved from a tool rack or the waste package to the adjacent glovebox for repair or maintenance. Locating and attaching to these objects with the remote handling system, a gantry robot, in a loosely fixtured environment is necessary for the operation of the closure cell. Reliably directing the remote handling system to pick and place the closure cell equipment within the cell is the major challenge.

Rodney M. Shurtliff

2005-09-01T23:59:59.000Z

132

Conserve Energy by Optimizing Air Compressor System  

E-Print Network (OSTI)

There are many opportunities to conserve energy within an Industrial Plant without adversely impacting the operation or production. Many of these represent only relatively small savings, when compared to the overall utility bill; however, one major benefit of energy conservation is that the resultant savings in dollars goes directly to “the bottom line” as increased profits. To generate the same amount of profit dollars as an effective energy conservation project can generate, in cost avoidance, the plant would have to substantially increase the product shipments. This is not always possible; however, conserving energy is nearly always possible. How should one begin an energy conservation program within a major Industrial Plant? The same as any other task—one step at a time. This paper addresses one of the many small projects available within many industries—the plant air compressing systems. It outlines how one industrial plant was able to reduce the utility bill by approximately $50,000 per year just within the compressor plant alone.

Williams, V. A.

1985-05-01T23:59:59.000Z

133

Indoor Air Quality Primer for HVAC System Design  

Science Conference Proceedings (OSTI)

Heating, ventilating, and air conditioning (HVAC) systems are major energy users in commercial and institutional buildings. Increased ventilation for acceptable indoor air quality (IAQ), besides increasing energy use, may result in unacceptably high indoor humidity, particularly in humid climates and/or applications requiring high ventilation rates. This report analyzes how increased ventilation affects the dehumidification capabilities of air conditioning systems in three applications -- offices, retail...

2002-02-21T23:59:59.000Z

134

Air conditioning system with supplemental ice storing and cooling capacity  

DOE Patents (OSTI)

The present air conditioning system with ice storing and cooling capacity can generate and store ice in its pipe assembly or in an ice storage tank particularly equipped for the system, depending on the type of the air conditioning system. The system is characterized in particular in that ice can be produced and stored in the air conditioning system whereby the time of supplying cooled air can be effectively extended with the merit that the operation cycle of the on and off of the compressor can be prolonged, extending the operation lifespan of the compressor in one aspect. In another aspect, ice production and storage in great amount can be performed in an off-peak period of the electrical power consumption and the stored ice can be utilized in the peak period of the power consumption so as to provide supplemental cooling capacity for the compressor of the air conditioning system whereby the shift of peak and off-peak power consumption can be effected with ease. The present air conditioning system can lower the installation expense for an ice-storing air conditioning system and can also be applied to an old conventional air conditioning system.

Weng, Kuo-Lianq (Taichung, TW); Weng, Kuo-Liang (Taichung, TW)

1998-01-01T23:59:59.000Z

135

Direct Digital Control in Air Conditioning Systems for Energy Efficiency  

E-Print Network (OSTI)

With the rapid development of Intelligent Buildings (IB), the Building Automation System (BAS) has come to control and manage the equipment in the building more and more scientifically, economically and rationally, which can not only raise the function and the level of the building, but also save energy. At present, air-conditioning design in internal commercial buildings is becoming more complex and enormous. The proportion of air conditioning systems in the whole building is getting larger. In order to control and manage the air-conditioning systems effectively and take full use of energy-saving technology, we apply computer control to the system of air automation control. This paper discusses direct digital control (DDC) in the air conditioning system in buildings.

Liu, W.; Ye, A.; Li, D.

2006-01-01T23:59:59.000Z

136

Compressed Air Audits: A Holistic Approach -Addressing the Air System as a Whole  

E-Print Network (OSTI)

First, consider the Independent Auditor. Plant management should consider using an independent auditor without ties to equipment sales who has experience with a variety of manufacturing facilities and can provide strong references documenting proven energy savings. The quality and comprehensiveness of manufacturing facilities, and therefore audits, vary widely and it is important to consider experience. Compressed Air Technologies has audited nearly 200 manufacturing facilities since our inception in 1996. Compressed Air Technologies is the preferred air energy services provider for Georgia Pacific Corporation, INVISTA Chemicals and a primary energy partner with KRAFT Foods, among others. Compressed Air Technologies has no OEM affiliation of any kind and will provide recommendations that are system-neutral and commercially impartial. Compressed Air Technologies (CAT) is an international energy reduction and system optimization services corporation. CAT is a totally independent business structure with no ties or affiliations with any air compressor manufacturers -we are free of OEM restrictions. Our strict adherence to an independent approach related to compressed air and gas system assessments allows for unbiased commentary and recommendations, regardless of the brand or equipment type currently utilized in your plant. The majority of our competitors have either 1) equipment to sell and/or,2) existing equipment on the site to protect. In both situations, the interests of the client is not the paramount issue. Independent auditors should have no obvious or hidden agenda. CAT compressed air audit services are in essence, holistic. The analysis of your facility compressed air and gases systems is all-inclusive and consists of an engineered assessment beginning at the air compressor equipment area inside your facility and finishing at point-of-use consumption points. CAT engineers utilize a variety of instruments to collect data from all critical, relevant areas of the compressed air and gas systems. From air compressor blow off loss to the cost of the always present distribution/ piping system leaks, each individual loss or inefficiency is measured, analyzed, quantified and catalogued. CAT engineers then compile all of the collected data to create a total current profile report of your facility operations including an assigned cost to each discovered inefficiency. A typical audit results in identification of 25 to 60 percent or more in total system operational waste, which includes energy costs, maintenance costs, and all matters related to operating your compressed gas systems. It is not unusual to discover half of what you pay for compressed air operations is wasted due to inefficient utilization and operation of this important utility.

Shaver, D.

2011-01-01T23:59:59.000Z

137

Acceptance Test Report for 241-U compressed air system  

SciTech Connect

This Acceptance Test Report (ATR) documents the results of acceptance testing of a newly upgraded compressed air system at 241-U Farm. The system was installed and the test successfully performed under work package 2W-92-01027.

Freeman, R.D.

1994-10-20T23:59:59.000Z

138

Intelligent Control of Heating, Ventilating and Air Conditioning Systems  

Science Conference Proceedings (OSTI)

This paper proposed a simulation-optimization energy saving strategy for heating, ventilating and air conditioning (HVAC) systems' condenser water loop through intelligent control of single speed cooling towers' components. An analysis of system components ...

Patrick Low Kie; Lau Bee Theng

2009-07-01T23:59:59.000Z

139

Bulk materials storage handling and transportation  

Science Conference Proceedings (OSTI)

This book contains papers on bulk materials storage, handling, and transportation. Topic areas covered include: mechanical handling; pneumatic conveying; transportation; freight pipeliners; storage and discharge systems; integrated handling systems; automation; environment and sampling; feeders and flow control; structural design; large mobile machines; and grain handling.

Not Available

1983-01-01T23:59:59.000Z

140

Monsanto/Mound Laboratory Engineering Development of Tritium-Handling Systems  

SciTech Connect

Mound Laboratory (Mound) has, during the past four years, been actively involved in the development of methods to contain and control tritium during its processing and to recover it from waste streams. Initial bench-scale research was directed mainly toward removal of tritium from gaseous effluent streams and from laboratory liquid wastes. The gaseous effluent investigation has progressed through the developmental stage and has been implemented in routine operations. A test laboratory embodying many of the results of the research phase has been designed and construction has been completed. As the program at Mound has progressed, the scope of the effort has been expanded to include research concerned with handling not only gaseous tritium but also tritiated liquids. A program is presently under way to investigate the detritiation of aqueous wastes encountered in the fuel cycle of the commercial power reactor industry.

Bixel, J. C.; Lamberger, P. H.

1976-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Residential Forced Air System Cabinet Leakage and Blower Performance  

SciTech Connect

This project evaluated the air leakage and electric power consumption of Residential HVAC components, with a particular focus on air leakage of furnace cabinets. Laboratory testing of HVAC components indicated that air leakage can be significant and highly variable from unit to unit ? indicating the need for a standard test method and specifying maximum allowable air leakage in California State energy codes. To further this effort, this project provided technical assistance for the development of a national standard for Residential HVAC equipment air leakage. This standard is being developed by ASHRAE and is called"ASHRAE Standard 193P - Method of test for Determining the Air Leakage Rate of HVAC Equipment". The final part of this project evaluated techniques for measurement of furnace blower power consumption. A draft test procedure for power consumption was developed in collaboration with the Canadian General Standards Board: CSA 823"Performance Standard for air handlers in residential space conditioning systems".

Walker, Iain S.; Dickerhoff, Darryl J.; Delp, William W.

2010-03-01T23:59:59.000Z

142

Consolidated Air Mobility Planning System (CAMPS): An Air Mobility Planning and  

E-Print Network (OSTI)

, the initial development of CAMPS was concluded and primary maintenance responsibility was turned over for Transportation Analysis (CTA) Research Areas Aviation Safety Air Traffic Management Analysis Data, Statistical Analysis Highway Safety Intelligent Transportation Systems Logistics Management Supply Chain Management

143

Prev'air: An Operational Forecasting and Mapping System for Air Quality in Europe  

Science Conference Proceedings (OSTI)

The current state of the art in three-dimensional chemistry-transport models allows them to be considered as mature and reliable enough to be combined with observations networks for implementing integrated air quality monitoring systems over ...

Laurence Rouil; Cécile Honoré; Bertrand Bessagnet; Laure Malherbe; Frédérik Meleux; Robert Vautard; Matthias Beekmann; Jean-Marie Flaud; Anne Dufour; Daniel Martin; Aline Peuch; Vincent-Henri Peuch; Christian Elichegaray; Nathalie Poisson; Laurent Menut

2009-01-01T23:59:59.000Z

144

Inverter control systems in the residential heat pump air conditioner  

SciTech Connect

A compressor capacity control with an inverter has been considered from the viewpoint of high energy saving in a refrigerating cycle. However, the system has not been put into practical use because of high initial cost, technical problems of electronic parts, and complexity of system control. In this connection, we developed the new inverter-controlled heat-pump air conditioner by using the latest electronics and refrigeration technology. This paper discusses the trend of energy saving in air conditioners in Japan and the objectives of developing the inverter controlled air conditioner. It also discusses the following items with respect to the inverter controlled air conditioner and the effects of employing an inverter: 1. Inverter for air conditioning; 2. Refrigeration cycle; 3. Air conditioner control with inverter.

Shimma, Y.; Tateuchi, T.; Suglura, H.

1985-01-01T23:59:59.000Z

145

Comparison of Zone Cooling Load for Radiant and All-Air Conditioning Systems  

E-Print Network (OSTI)

Load for Radiant and Air Conditioning Systems. ProceedingsRefrigerating and Air Conditioning Engineers Inc. Babiak,of European Heating ahd Air-Conditioning Associations. CEN (

Feng, Jingjuan; Schiavon, Stefano; Bauman, Fred

2012-01-01T23:59:59.000Z

146

Research on Fuzzy Regulation Strategies in the Constant Air Volume Air Conditioning System  

E-Print Network (OSTI)

The energy consumption of the constant air volume (CAV) system largely depends on the regulation strategies. Although some air conditioning systems are equipped with automatic regulation devices, others lack effective regulation strategies. To avoid wasting energy and presenting simple regulation methods, fuzzy regulation strategies for CAV systems are studied in this research. A CAV system of an office building is modeled and simulated with the Designer's Simulation Toolkit (DeST). The operating parameters are calculated based on the instantaneous load obtained from simulation. The operation of the system is divided into five stages according to different conception of “cold” or “hot” in different seasons. The relationship between the outdoor air temperature and the fresh air volume, and the supply air temperature is presented in the form of fuzzy rules. Then the building is simulated under different load conditions and the operating parameters are obtained from fuzzy reasoning. Finally, the effect of fuzzy strategies on energy consumption is analyzed and compared with the effects of the operating parameters obtained from simulation. The results show that energy consumption using a fuzzy regulation strategy is close to the energy consumption of knowing the exact load of the building, while the fuzzy regulation strategy can largely simplify the regulation of the air conditioning system.

Bai, T.; Zhang, J.; Ning, N.; Tong, K.; Wu, Y.; Wang, H.

2006-01-01T23:59:59.000Z

147

Scalability of the air transportation system and development of multi-airport systems : a worldwide perspective  

E-Print Network (OSTI)

With the growing demand for air transportation and the limited ability to increase capacity at some key points in the air transportation system, there are concerns that in the future the system will not scale to meet demand. ...

Bonnefoy, Philippe A

2008-01-01T23:59:59.000Z

148

FMAC: Coal-Handling Maintenance Guide  

Science Conference Proceedings (OSTI)

The Coal Handling System Maintenance Guide provides fossil plant maintenance personnel with current maintenance information on this system. This report will assist plant maintenance personnel in improving the reliability of and reducing the maintenance costs for the coal handling system.

2006-12-22T23:59:59.000Z

149

Reducing Air-Conditioning System Energy Using a PMV Index  

E-Print Network (OSTI)

The control system of central air-conditioning, based on PMV, not only improves thermal comfort but also reduces system energy consumption. A new thermal comfort degree softsensor model is built via use of the CMAC neural network nonlinear calibration function. It can realize on-line detection of thermal comfort. At the same time it can also realize real-time control of central air-conditioning system based on PMV. Simulation results demonstrate the simplicity and effectiveness of the presented method.

Li, H.; Zhang, Q.

2006-01-01T23:59:59.000Z

150

HVAC System Design Strategies to Address Indoor Air Quality Standards  

Science Conference Proceedings (OSTI)

This report describes strategies that can be employed in the design and operation of heating, ventilating, and air conditioning (HVAC) systems to address the ASHRAE Standard 62 "Ventilation for Acceptable Indoor Air Quality" requirements. The report examines a wide variety of approaches to meeting the standard and their impact on energy consumption, occupant comfort, and other factors.

1999-12-09T23:59:59.000Z

151

AirCore: An Innovative Atmospheric Sampling System  

Science Conference Proceedings (OSTI)

This work describes the AirCore, a simple and innovative atmospheric sampling system. The AirCore used in this study is a 150-m-long stainless steel tube, open at one end and closed at the other, that relies on positive changes in ambient ...

Anna Karion; Colm Sweeney; Pieter Tans; Timothy Newberger

2010-11-01T23:59:59.000Z

152

Test results of lithium pool-air reaction suppression systems  

Science Conference Proceedings (OSTI)

Engineered reaction suppression systems were demonstrated to be effective in suppressing lithium pool-air reactions for lithium quantities up to 100 kg. Lithium pool-air reaction suppression system tests were conducted to evaluate suppression system effectiveness for potential use in fusion facilities in mitigating consequences of postulated lithium spills. Small-scale perforated and sacrificial cover plate suppression systems with delayed inert gas purging proved effective in controlling the lithium-air interaction for lithium quantities near 15 kg at initial temperatures up to 450/sup 0/C. A large-scale suppression system with a sacrificial cover, a diverter plate, an inert gas atmosphere, and remotely retrievable catch pans proved effective in controlling lithium pool-air interaction for a 100-kg lithium discharge at an initial temperature of 550/sup 0/C. This suppression system limited the maximum pool temperature to about 600/sup 0/C less than that expected for a similar lithium pool-air reaction without a suppression system. Lithium aerosol release from this large-scale suppression system was a factor of about 10,000 less than that expected for a lithium pool-air reaction with no suppression system. Remote retrieval techniques for lithium cleanup, such as (1) in-place lithium siphoning and overhead crane dismantling, and (2) lithium catch pan removal by use of an overhead crane, were demonstrated as part of this large-scale test.

Jeppson, D.W.

1987-02-01T23:59:59.000Z

153

Remote Handling of Cryogenic Targets for the Omega Laser System (A23039)  

E-Print Network (OSTI)

Proc. Of The 8th Int. Top. Mtg On Robotics And Remote Systems, Pittsburgh, Pennsylvania, April 1999, To Be PublishedInternational Topical Meeting on Robotics and Remote Systems Pittsburgh Pennsylvania, US, 1999932764927

Silke, G.W.

1999-04-25T23:59:59.000Z

154

The Air or Brayton Cycle Solvent Recovery System  

E-Print Network (OSTI)

The required temperature and technique for condensing common industrial solvents from the exhaust air of drying ovens is explained. The benefits of the Air Cycle for this application are discussed. The operation of the 8000 CFM Air Cycle Solvent Recovery System developed by the AiResearch Manufacturing Company of California under contract to the Department of Energy is discussed. Performance data for the recovery of solvents from an industrial drying oven is presented. The advantages of the "free spindle" arrangement as an alternate to the present gear drive are explained. The simple method for adjusting and controlling the turbine exhaust temperature for the "free spindle" arrangement is explained. The application of the Air Cycle for condensing solvent vapors from inert atmosphere ovens and from activated carbon desorbed with nitrogen is also described. Relative merits of the Air Cycle System compared with other available methods of solvent recovery are discussed.

Fox, B. J.

1986-06-01T23:59:59.000Z

155

A systems analysis of scheduled air transportation networks  

E-Print Network (OSTI)

This work establishes the conditions for airline system design building from submodels of smaller aspects of air transportation. The first three sections develop submodels which then are combined in extensive numerical ...

Swan, William M.

1979-01-01T23:59:59.000Z

156

Longevity of Duct Tape in Residential Air Distribution Systems...  

NLE Websites -- All DOE Office Websites (Extended Search)

Longevity of Duct Tape in Residential Air Distribution Systems: 1-D, 2-D, and 3-D Joints Speaker(s): Bass Abushakra Date: July 30, 2002 - 12:00pm Location: Bldg. 90 Seminar Host...

157

Residential Air-Conditioning System with Smart-Grid Functionality.  

E-Print Network (OSTI)

??This thesis sets forth a novel intelligent residential air-conditioning (A/C) system controller that provides optimal thermal comfort and electricity cost trade-offs for a household resident… (more)

Thomas, Auswin George

2012-01-01T23:59:59.000Z

158

Evaluating passenger delays in the US domestic air transportation system  

E-Print Network (OSTI)

A fundamental component of any National Airspace System (NAS) performance evaluation is the cost impact of air traffic delays, and more generally capacity limitations, on the traveling passengers. In previous research it ...

Umang, Nitish

2010-01-01T23:59:59.000Z

159

Modeling of a Signal Processing System for Aircraft Air Data...  

NLE Websites -- All DOE Office Websites (Extended Search)

Modeling of a Signal Processing System for Aircraft Air Data Instrumentation Speaker(s): Thomas John Rohloff Date: September 21, 1998 - 12:00pm Location: 90-3148 Seminar HostPoint...

160

Concepts studies for future intracity air transportation systems  

E-Print Network (OSTI)

Summary: This report is concerned with describing the possible application of future air transportation systems within urban areas of the United States. The planning horizon extends to 1995 and the report focuses on the ...

Joint DOT-NASA Civil Aviation Research and Development Policy Study.; United States. National Aeronautics and Space Administration; Massachusetts Institute of Technology. Flight Transportation Laboratory

1970-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Evaluation of an Air Pollution Analysis System for Complex Terrain  

Science Conference Proceedings (OSTI)

This paper describes results from a study to evaluate components of an operational air quality modeling system for complex terrain. In particular, the Cinder Cone Butte (CCB) “modeler's dataset” is used to evaluate the current technique for ...

D. G. Ross; D. G. Fox

1991-07-01T23:59:59.000Z

162

An integrated multi-model approach for air quality assessment: Development and evaluation of the OSCAR Air Quality Assessment System  

Science Conference Proceedings (OSTI)

This paper reports on the development and evaluation of a new modelling system for studying air quality on local scales. A multi-model approach has been adopted to develop the OSCAR Air Quality Modelling System to conduct assessments at different levels ... Keywords: Air quality, Model evaluation, Modelling system, Nitrogen oxides, OSCAR, Particulate matter

Ranjeet S. Sokhi; Hongjun Mao; Srinivas T. G. Srimath; Shiyuan Fan; Nutthida Kitwiroon; Lakhumal Luhana; Jaakko Kukkonen; Mervi Haakana; Ari Karppinen; K. Dick van den Hout; Paul Boulter; Ian S. McCrae; Steinar Larssen; Karl I. Gjerstad; Roberto San José; John Bartzis; Panagiotis Neofytou; Peter van den Breemer; Steve Neville; Anu Kousa; Blanca M. Cortes; Ingrid Myrtveit

2008-03-01T23:59:59.000Z

163

Pressure Regain Strategies for Existing Air Distribution Systems  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pressure Regain Strategies for Pressure Regain Strategies for Existing Air Distribution Systems Arlan Burdick IBACOS, Inc. Pressure Regain Strategies for Existing Air Distribution Systems Problem Statement Thermal enclosure upgrades can reduce peak loads by 50%. If the furnace is right-sized for this new peak load and the ducts are not modified or replaced, the resulting airflows at the supply registers will be significantly reduced. -Will the outlets meet industry standards for performance? - Should they be replaced to achieve good room air mixing? - Should the end of the duct be modified to improve airflow characteristics? Pressure Regain Strategies for Existing Air Distribution Systems Expected Results We expect to find a cost-effective solution to gaining proper airflow to a room without completely replacing

164

Starter systems designed for efficient air/gas comsumption  

Science Conference Proceedings (OSTI)

This paper examines engine starting systems designed by Pow-R-Quik. Pow-R-Quik's most recent product line includes several models that are designed to start most diesel and natural gas engines. Pow-R-Quick also offers air starting systems for a wide range of gas turbine applications. The model DS16, air or gas starter, is designed for engines with a displacement up to 500 cid diesel and up to 1000 cid natural gas. The DS60 model is also an air or gas operated starter with specially designed heavy duty bearings for maximum performance. To prove out starter durability and performance, Pow-R-Quik has installed three fully instrumented diesel engine test cells. The number of starts that can be achieved ranges from zero to 99,000. The system can be set to regulate the air for low or high pressure starts, control the lubricant, etc.

Not Available

1985-05-01T23:59:59.000Z

165

Retrofitting Air Conditioning and Duct Systems in Hot, Dry Climates  

SciTech Connect

This technical report describes CARB's work with Clark County Community Resources Division in Las Vegas, Nevada, to optimize procedures for upgrading cooling systems on existing homes in the area to implement health, safety, and energy improvements. Detailed monitoring of five AC systems showed that three of the five systems met or exceeded air flow rate goals.

Shapiro, C.; Aldrich, R.; Arena, L.

2012-07-01T23:59:59.000Z

166

Mound Laboratory's Air Surveillance System  

SciTech Connect

A comprehensive air surveillance system was developed. The system includes surveillance of the source, transport conditions, and concentration at the receptor sites. An unusual aspect of the system is the implementation of off-site sampling programs through local governmental agencies. Background levels of radioactivity are routinely determined.

Carfagno, D. G.

1974-12-31T23:59:59.000Z

167

DEVELOPMENT OF AN AIR?CYCLE ENVIRONMENTAL CONTROL SYSTEM FOR AUTOMOTIVE APPLICATIONS.  

E-Print Network (OSTI)

??An air?cycle air conditioning system, using a typical automotive turbocharger as the core of the system, was designed and tested. Effects on engine performance were… (more)

Forster, Christopher James

2009-01-01T23:59:59.000Z

168

Air-Microfluidics: Towards Lab-on-a-Chip Systems for Low-Cost Air-Quality  

NLE Websites -- All DOE Office Websites (Extended Search)

Air-Microfluidics: Towards Lab-on-a-Chip Systems for Low-Cost Air-Quality Air-Microfluidics: Towards Lab-on-a-Chip Systems for Low-Cost Air-Quality Monitoring Speaker(s): Igor Paprotny Date: November 12, 2013 - 12:00pm - 1:00pm Location: 90-3122 Seminar Host/Point of Contact: Lara Gundel Air-microfluidic devices that monitor particles suspended in air, as opposed to liquids, can dramatically reduce the size and cost of future air-quality sensors. The use of microelectromechanical systems (MEMS) technologies and wafer-scale integration permits the inclusion of many different sensors onto a small footprint. Benefits of air-microfluidics are many. For example, air-microfluidic lab-on-a-chip devices can be used as portable sensors for tracking individual exposure to airborne pollutants. Such sensors will enable linking exposure and biometric information to

169

Performance comparison between air and liquid residential solar heating systems  

SciTech Connect

Comparisons of system performance for the flat plate liquid-heating system in CSU Solar House I, the evacuated-tube collector system in Solar House I, and the flat plate air-heating system in CSU Solar House II are described for selected months of the 1976 and 1977 heating seasons. Only space and domestic water heating data are compared. The flat plate air- and liquid-heating collectors operating with complete heating systems have nearly equal efficiencies when based upon solar flux while the collector fluids are flowing, but approximately 40% more energy is collected during a heating season with the air-heating system because the air system operates over a longer period of the day. On the basis of short-term data, the evacuated tube collector array on Solar House I is about 27% more efficient than the flat plate air-heating collector array on Solar House II based on gross roof area occupied by the collectors and manifolds.

Karaki, S.; Duff, W.S.; Loef, G.O.G.

1978-01-01T23:59:59.000Z

170

Impacts of Static Pressure Reset on VAV System Air Leakage, Fan Power and Thermal Energy - Part 2: Case Demonstration for a Typical Climate System  

E-Print Network (OSTI)

In Part 1 of this paper, the theoretical models, integrating the fan airflow, fan head, air leakage factors, are developed to analyze the impacts of the static pressure reset on both pressure dependent and pressure independent terminal boxes. In this part, a simulated air handling unit (AHU) system in Omaha NE is used to demonstrate the energy savings performance in one typical climate year. This AHU system has a static pressure reset system and two constant static pressure systems, one having pressure dependent terminal boxes and one having pressure independent terminal boxes. These simulated systems were compared mainly on the basis of fan power energy consumption and thermal energy consumption in totally a year. The example presents a good agreement with the theoretical model and simulation results. It was also shown that static pressure reset provides a promising and challenging way for the energy performance in VAV system.

Liu, M.; Zheng, K.; Wu, L.; Wang, Z.; Johnson, C.

2007-01-01T23:59:59.000Z

171

Air-flow regulation system for a coal gasifier  

DOE Patents (OSTI)

An improved air-flow regulator for a fixed-bed coal gasifier is provided which allows close air-flow regulation from a compressor source even though the pressure variations are too rapid for a single primary control loop to respond. The improved system includes a primary controller to control a valve in the main (large) air supply line to regulate large slow changes in flow. A secondary controller is used to control a smaller, faster acting valve in a secondary (small) air supply line parallel to the main line valve to regulate rapid cyclic deviations in air flow. A low-pass filter with a time constant of from 20 to 50 seconds couples the output of the secondary controller to the input of the primary controller so that the primary controller only responds to slow changes in the air-flow rate, the faster, cyclic deviations in flow rate sensed and corrected by the secondary controller loop do not reach the primary controller due to the high frequency rejection provided by the filter. This control arrangement provides at least a factor of 5 improvement in air-flow regulation for a coal gasifier in which air is supplied by a reciprocating compressor through a surge tank.

Fasching, George E. (Morgantown, WV)

1984-01-01T23:59:59.000Z

172

ANALYSIS OF DEDICATED OUTDOOR AIR SYSTEMS FOR ...  

Science Conference Proceedings (OSTI)

... Baseline: The baseline system modeled included Water Source Heat Pumps (WSHPs) with a Cooling Tower and a Boiler serving the common loop. ...

173

Vehicle Transient Air Conditioning Analysis: Model Development& System Optimization Investigations  

DOE Green Energy (OSTI)

The National Renewable Energy Laboratory (NREL) has developed a transient air conditioning (A/C) system model using SINDA/FLUINT analysis software. It captures all the relevant physics of transient A/C system performance, including two-phase flow effects in the evaporator and condenser, system mass effects, air side heat transfer on the condenser/evaporator, vehicle speed effects, temperature-dependent properties, and integration with a simplified cabin thermal model. It has demonstrated robust and powerful system design optimization capabilities. Single-variable and multiple variable design optimizations have been performed and are presented. Various system performance parameters can be optimized, including system COP, cabin cool-down time, and system heat load capacity. This work presents this new transient A/C system analysis and optimization tool and shows some high-level system design conclusions reached to date. The work focuses on R-134a A/C systems, but future efforts will modify the model to investigate the transient performance of alternative refrigerant systems such as carbon dioxide systems. NREL is integrating its transient air conditioning model into NRELs ADVISOR vehicle system analysis software, with the objective of simultaneously optimizing A/C system designs within the overall vehicle design optimization.

Hendricks, T. J.

2001-06-01T23:59:59.000Z

174

Variables optimization of building air conditioning system  

Science Conference Proceedings (OSTI)

A heating and climatizer system based on selective absorption of solar energy by a selective collector. The experimental study shows that the performance of this system depends on several variables: the nature of the colporteur fluid, the flow of the ... Keywords: heating and climatisation, modelation and optimization, solar energy

Marius-Constantin Popescu; Cornelia Aida Bulucea; Gheorghe Manolea; Cristian Vladu

2009-10-01T23:59:59.000Z

175

Engine cooling system air venting arrangement with buoyant air purge valve  

Science Conference Proceedings (OSTI)

An air vent arrangement is described for the cooling system of an automotive type engine having a radiator with a coolant inlet. The engine has coolant passages communicating with the radiator through an outlet essentially horizontally disposed, tubing connecting the radiator inlet and coolant outlet, and a thermostat in the outlet horizontally movable to open and closed positions. A horizontally disposed air bleed bypass passage is located vertically above the thermostat connecting the coolant outlet to a portion of the tubing downstream of the thermostat bypassing the same when the thermostat is in a closed position for bleeding air from the cooling system. The bypass passage has a valve therein moveable between a position blocking flow of coolant through the same and a second position opening the passage permitting the bleed of air therethrough. The valve is buoyant and constructed and arranged to pivot from a non flowblocking air bleed position into a flow blocking position in response to flow of coolant into the bypass passage acting thereagainst.

Schnizlein, M.E.

1987-02-17T23:59:59.000Z

176

A Numerical Daily Air Quality Forecast System for The Pacific Northwest  

Science Conference Proceedings (OSTI)

A real-time photochemical air quality forecast system has been implemented for the Puget Sound region to support public awareness of air quality issues. The Air Indicator Report for Public Access and Community Tracking (AIRPACT) forecast system ...

Joseph Vaughan; Brian Lamb; Chris Frei; Rob Wilson; Clint Bowman; Cristiana Figueroa-Kaminsky; Sally Otterson; Mike Boyer; Cliff Mass; Mark Albright; Jane Koenig; Alice Collingwood; Mike Gilroy; Naydene Maykut

2004-04-01T23:59:59.000Z

177

Energy and air emission implications of a decentralized wastewater system  

NLE Websites -- All DOE Office Websites (Extended Search)

and air emission implications of a decentralized wastewater system and air emission implications of a decentralized wastewater system Title Energy and air emission implications of a decentralized wastewater system Publication Type Journal Article Year of Publication 2012 Authors Shehabi, Arman, Jennifer R. Stokes, and Arpad Horvath Journal Environmental Research Letters Volume 7 Issue 2 Abstract Both centralized and decentralized wastewater systems have distinct engineering, financial and societal benefits. This paper presents a framework for analyzing the environmental effects of decentralized wastewater systems and an evaluation of the environmental impacts associated with two currently operating systems in California, one centralized and one decentralized. A comparison of energy use, greenhouse gas emissions and criteria air pollutants from the systems shows that the scale economies of the centralized plant help lower the environmental burden to less than a fifth of that of the decentralized utility for the same volume treated. The energy and emission burdens of the decentralized plant are reduced when accounting for high-yield wastewater reuse if it supplants an energy-intensive water supply like a desalination one. The centralized facility also reduces greenhouse gases by flaring methane generated during the treatment process, while methane is directly emitted from the decentralized system. The results are compelling enough to indicate that the life-cycle environmental impacts of decentralized designs should be carefully evaluated as part of the design process.

178

AirTec System Co Ltd | Open Energy Information  

Open Energy Info (EERE)

AirTec System Co Ltd AirTec System Co Ltd Jump to: navigation, search Name AirTec System Co Ltd Place Suwon, Gyeonggi-do, Korea (Republic) Product Korean wireless communications equipment vendor; as of January 2008, established a Green Energy Business Division as a PV project developer. Coordinates 37.281368°, 127.013077° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":37.281368,"lon":127.013077,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

179

Energy Conservation of Air Conditioning Systems in Large Public Buildings  

E-Print Network (OSTI)

Analyzing the actuality of the large-scale public buildings' energy consumption, we know that most of them run not only in low efficiency, but also in high energy consumption. According to the characteristics of the building, we should proceed with the heating characteristics of the exterior -protected construction, the set value of the temperature of the air-conditioning, the lectotype of the Central air-conditioning system, the regulation and the modification of the transmission and distribution system, the use of the new energy and the daily management or the method of adjustment and control, and so on , so we can make the air-conditioning system run efficiently. Analyzing and comparing the large-scale public buildings' energy consumption with each other, some pointed improvement measures are proposed further. According to the study and analysis, even though large-scale public buildings consume a great of energy, there exists a huge potential for energy conservation.

Liu, P.; Li, D.

2006-01-01T23:59:59.000Z

180

A deterministic air quality forecasting system for Torino urban area, Italy  

Science Conference Proceedings (OSTI)

An urban air quality forecasting system for Torino city has been developed, within the EU funded project FUMAPEX, to support the prevention and management of urban air pollution episodes. The proposed forecasting system is designed to provide stakeholders ... Keywords: Air quality forecasting, Air quality management, Chemical transport models, Urban air pollution, Urban meteorology

S. Finardi; R. De Maria; A. D'Allura; C. Cascone; G. Calori; F. Lollobrigida

2008-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Appendix A: Handling of Federal  

Gasoline and Diesel Fuel Update (EIA)

and selected State legislation and regulation in the AEO This page inTenTionally lefT blank 177 U.S. Energy Information Administration | Assumptions to the Annual Energy Outlook 2012 Appendix A: Handling of Federal and selected State legislation and regulation in the AEO Legislation Brief description AEO handling Basis Residential sector A. National Appliance Energy Conservation Act of 1987 Requires Secretary of Energy to set minimum efficiency standards for 10 appliance categories with periodic updates Included for categories represented in the AEO residential sector forecast. Public Law 100-12. a. Room air conditioners Sets standards for room air conditioners in 2014. Require new purchases of room air conditioners to meet the standard. Federal Register Notice

182

Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems  

SciTech Connect

The purpose of ventilation is dilute or remove indoor contaminants that an occupant is exposed to. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. Most US homes have central HVAC systems, which tend to mix the air thus the indoor conditions between zones. Different types of ventilation systems will provide different amounts of exposure depending on the effectiveness of their air distribution systems and the location of sources and occupants. This paper will report on field measurements using a unique multi-tracer measurement system that has the capacity to measure not only the flow of outdoor air to each zone, but zone-to-zone transport. The paper will derive seven different metrics for the evaluation of air distribution. Measured data from two homes with different levels of natural infiltration will be used to evaluate these metrics for three different ASHRAE Standard 62.2 compliant ventilation systems. Such information can be used to determine the effectiveness of different systems so that appropriate adjustments can be made in residential ventilation standards such as ASHRAE Standard 62.2.

Sherman, Max; Sherman, Max H.; Walker, Iain S.

2008-05-01T23:59:59.000Z

183

Air Distribution Effectiveness for Different MechanicalVentilation Systems  

SciTech Connect

The purpose of ventilation is to dilute indoor contaminants that an occupant is exposed to. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. Most US homes have central HVAC systems, which tend to mix conditions between zones. Different types of ventilation systems will provide different amounts of dilution depending on the effectiveness of their air distribution systems and the location of sources and occupants. This paper will report on work being done to both model the impact of different systems and measurements using a new multi-tracer measurement system that has the capacity to measure not only the flow of outdoor air to each zone, but zone-to-zone transport. The ultimate objective of this project is to determine the effectiveness of different systems so that appropriate adjustments can be made in residential ventilation standards such as ASHRAE Standard 62.2.

Sherman, Max H.; Walker, Iain S.

2007-08-01T23:59:59.000Z

184

Effect of System and Air Contaminants on PEMFC Performance and Durability (Presentation)  

DOE Green Energy (OSTI)

This presentation summarizes Effect of System and Air Contaminants on PEMFC Performance and Durability.

Dinh, H.

2010-06-11T23:59:59.000Z

185

Criticality safety evaluation report for the cold vacuum drying facility's process water handling system  

SciTech Connect

This report addresses the criticality concerns associated with process water handling in the Cold Vacuum Drying Facility. The controls and limitations on equipment design and operations to control potential criticality occurrences are identified.

NELSON, J.V.

1999-05-12T23:59:59.000Z

186

Modeling of a Signal Processing System for Aircraft Air Data  

NLE Websites -- All DOE Office Websites (Extended Search)

Modeling of a Signal Processing System for Aircraft Air Data Modeling of a Signal Processing System for Aircraft Air Data Instrumentation Speaker(s): Thomas John Rohloff Date: September 21, 1998 - 12:00pm Location: 90-3148 Seminar Host/Point of Contact: Joan M. Daisey The velocity, attitude and altitude of flight vehicles have typically been measured with booms that extend from the vehicle surface out into the flow field. However, this arrangement was found to be unacceptable for certain flight applications. Instrumentation was therefore developed by other researchers to measure the flight parameters using an array of pressure measurements located on the surface of the vehicle. The relationship between these pressure measurements and the air data is a complex non-linear function that is not easily described with simple aerodynamic

187

Commissioning and Diagnosis of VAV Air-Conditioning Systems  

E-Print Network (OSTI)

This paper presents a fault detection and diagnosis (FDD) strategy based on system knowledge, qualitative states and object-oriented statistical process control (SPC) models for typical pressure-independent variable air volume (VAV) air-conditioning systems. Eight FDD schemes are built to detect the eleven pre-defined VAV faults using the qualitative and quantitative FDD approaches within the strategy at two steps. The ten hard faults, which would affect the system operation, are analyzed at Step 1. The soft fault, which would not affect the basic system operation but would impact the supervisory controls, is analyzed at Step 2. The strategy is tested and validated on typical VAV systems involving multiple faults, both in simulation and in-situ tests. A software package is developed as a BMS-assisted automatic commissioning tool based on the FDD strategy. Off-line tests were conducted in both the simulated building and the real building.

Qin, J.; Wang, S.; Chan, C.; Xiao, F.

2006-01-01T23:59:59.000Z

188

Solar powered desiccant air conditioning system. Final report  

DOE Green Energy (OSTI)

A solar-powered desiccant air conditioning system using silica gel has been developed, and modifications to the existing unit and additional testing are proposed to demonstrate the feasibility of the unit. Conversion from a rotating bed to a fixed bed of silica gel is proposed. Some general plans for commercialization are briefly discussed. (LEW)

Not Available

1981-07-24T23:59:59.000Z

189

Thermal storage HVAC system retrofit provides economical air conditioning  

Science Conference Proceedings (OSTI)

This article describes an EMS-controlled HVAC system that meets the ventilation and cooling needs of an 18,000-seat indoor ice hockey arena. The Buffalo Memorial Auditorium (affectionately referred to as the Aud) was built in 1937 under the Works Project Administration of the federal government. Its original configuration included a 12,000-seat arena with an ice skating rink. By the late 1980s, the city was unsuccessfully attempting to attract events and tenants to the auditorium, which lacked air conditioning and other modern amenities. Thus, it was decided to renovate the facility to make it marketable. The first phase of the renovation included installing an air-conditioning system in the arena and repairing the existing building systems that were inoperable because of deferred maintenance. After considering the existing conditions (such as size of the space, intermittent usage, construction restrictions, operating budgets and the limited operations staff), the engineering team designed an innovative HVAC system. The system's features include: a carbon dioxide monitoring device that controls the intake of outside air; an ice storage system that provides chilled water and shifts electrical demand to off-peak hours; and a design that uses the building mass as a heat sink. A new energy management system (EMS) determines building cooling needs based on the type of event, ambient conditions and projected audience size. Then, it selects the most economical method to obtain the desired arena temperature.

Smith, S.F. (Wendel Engineers, P.C., Buffalo, NY (United States))

1993-03-01T23:59:59.000Z

190

Direct methanol/air fuel cells: Systems considerations  

DOE Green Energy (OSTI)

Successful operation of a direct methanol/air fuel cell system depends upon appropriate integration of the fuel cell components and accommodation of the need for heat and mass transfer within the system. The features of the system that must be considered separately and in an interactive fashion are: (1) the physical state of the fuel feed stream, (2) electrode characteristics, (3) characteristics of the electrolyte, (4) product water removal, (5) heat transfer into our out of the stack, and (6) methanol loss modes. The operating temperature and pressure will be determined, to a large extent, by these features. An understanding of the component features and their interactions is necessary for initial system considerations for direct methanol/air fuel cells.

Huff, J.R.

1990-01-01T23:59:59.000Z

191

ENERGY STAR Building Upgrade Manual Chapter 8: Air Distribution Systems |  

NLE Websites -- All DOE Office Websites (Extended Search)

8: Air Distribution 8: Air Distribution Systems Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In This Section Campaigns Commercial building design Communications resources Energy management guidance Financial resources Portfolio Manager Products and purchasing Recognition Research and reports Service and product provider (SPP) resources Success stories Target Finder

192

Closed loop air cooling system for combustion turbines  

DOE Patents (OSTI)

Convective cooling of turbine hot parts using a closed loop system is disclosed. Preferably, the present invention is applied to cooling the hot parts of combustion turbine power plants, and the cooling provided permits an increase in the inlet temperature and the concomitant benefits of increased efficiency and output. In preferred embodiments, methods and apparatus are disclosed wherein air is removed from the combustion turbine compressor and delivered to passages internal to one or more of a combustor and turbine hot parts. The air cools the combustor and turbine hot parts via convection and heat is transferred through the surfaces of the combustor and turbine hot parts.

Huber, David John (North Canton, OH); Briesch, Michael Scot (Orlando, FL)

1998-01-01T23:59:59.000Z

193

Closed loop air cooling system for combustion turbines  

DOE Patents (OSTI)

Convective cooling of turbine hot parts using a closed loop system is disclosed. Preferably, the present invention is applied to cooling the hot parts of combustion turbine power plants, and the cooling provided permits an increase in the inlet temperature and the concomitant benefits of increased efficiency and output. In preferred embodiments, methods and apparatus are disclosed wherein air is removed from the combustion turbine compressor and delivered to passages internal to one or more of a combustor and turbine hot parts. The air cools the combustor and turbine hot parts via convection and heat is transferred through the surfaces of the combustor and turbine hot parts. 1 fig.

Huber, D.J.; Briesch, M.S.

1998-07-21T23:59:59.000Z

194

Air Toxics Control by Wet Flue Gas Desulfurization Systems  

Science Conference Proceedings (OSTI)

This report provides an update on three tasks associated with the EPRI project, Air Toxics Control by Wet Flue Gas Desulfurization (FGD) Systems. The first task is an investigation of the factors that influence and control the oxidation-reduction potential (ORP) at which a limestone forced oxidation FGD system operates. Both a literature review and a numerical analysis of full-scale wet FGD data were conducted. Results from this task are presented and discussed in Section 2 of the ...

2012-12-31T23:59:59.000Z

195

CLASSIFICATION OF THE MGR SITE COMPRESSED AIR SYSTEM  

SciTech Connect

The purpose of this analysis is to document the Quality Assurance (QA) classification of the Monitored Geologic Repository (MGR) site compressed air system structures, systems and components (SSCs) performed by the MGR Safety Assurance Department. This analysis also provides the basis for revision of YMP/90-55Q, Q-List (YMP 1998). The Q-List identifies those MGR SSCs subject to the requirements of DOE/RW-0333P, ''Quality Assurance Requirements and Description'' (QARD) (DOE 1998).

J.A. Ziegler

1999-08-31T23:59:59.000Z

196

Service center to test solar air-conditioning system  

Science Conference Proceedings (OSTI)

Field testing of an advanced solar-powered air-conditioning system developed under the joint Saudi Arabia-US Agreement for Cooperation in the Field of solar Energy (SOLERAS) will be conducted in Arizona over a three-phase 34-month perod. Participants in the program and their contribution are cited. The solar-Rankine alternative to conventional systems using electricity or fossil fuels. (DCK)

Not Available

1980-02-14T23:59:59.000Z

197

Economical Analysis of the Cold Air Distribution System: A Case Study  

E-Print Network (OSTI)

In this paper, we briefly introduce the super cold air distribution technique. By comparing the schemes of two air conditioning systems, including a modified air conditioning system, this paper analyzes the technique parameters and the economics of the cold air distribution system in detail. The detailed analysis includes the air quality, comfort index, initial cost, life cost, static recycle period, and dynamic recycle period. The advantages and trends of super cold air distribution systems in the future are pointed out. The economical analysis and technical comparison is based on real data. The conclusion is useful for the design of super cold air conditioning systems of large shops and office buildings.

Zhou, Z.; Xu, W.; Li, J.; Zhao, J.; Niu, L.

2006-01-01T23:59:59.000Z

198

Uranium hexafluoride handling. Proceedings  

SciTech Connect

The United States Department of Energy, Oak Ridge Field Office, and Martin Marietta Energy Systems, Inc., are co-sponsoring this Second International Conference on Uranium Hexafluoride Handling. The conference is offered as a forum for the exchange of information and concepts regarding the technical and regulatory issues and the safety aspects which relate to the handling of uranium hexafluoride. Through the papers presented here, we attempt not only to share technological advances and lessons learned, but also to demonstrate that we are concerned about the health and safety of our workers and the public, and are good stewards of the environment in which we all work and live. These proceedings are a compilation of the work of many experts in that phase of world-wide industry which comprises the nuclear fuel cycle. Their experience spans the entire range over which uranium hexafluoride is involved in the fuel cycle, from the production of UF{sub 6} from the naturally-occurring oxide to its re-conversion to oxide for reactor fuels. The papers furnish insights into the chemical, physical, and nuclear properties of uranium hexafluoride as they influence its transport, storage, and the design and operation of plant-scale facilities for production, processing, and conversion to oxide. The papers demonstrate, in an industry often cited for its excellent safety record, continuing efforts to further improve safety in all areas of handling uranium hexafluoride. Selected papers were processed separately for inclusion in the Energy Science and Technology Database.

Not Available

1991-12-31T23:59:59.000Z

199

System transition : dynamics of change in the US air transportation system  

E-Print Network (OSTI)

The US Air Transportation System is currently facing a number of challenges including an increasing demand for travel and growing environmental requirements. In order to successfully meet future needs, the system will need ...

Mozdzanowska, Aleksandra L. (Aleksandra Ludmila), 1979-

2008-01-01T23:59:59.000Z

200

Effectiveness of Shading Air-Cooled Condensers of Air-Conditioning Systems  

E-Print Network (OSTI)

In air-conditioning (A/C) systems with air-cooled condensers, the condensing unit has to be kept in the open for easy access to outdoor air in order to efficiently dissipate heat. During daytime, the solar radiation falling on the surfaces of the condenser and the high ambient temperatures can be detrimental for the energy performance. The effectiveness of shading the condensing unit to mitigate this adverse impact is investigated in this paper. A limiting analysis compares the performance of several A/C systems with ideal shade to those with ideal solar heat gain. The comparison is based on a theoretical model and data from equipment catalogs. The theoretical increase in the coefficient of performance (COP) due to shading is found to be within 2.5%. Furthermore, this small improvement in ideal efficiency decreases at higher ambient temperatures, when enhancements to efficiency are more needed. The actual efficiency improvement due to shading is not expected to exceed 1%, and the daily energy savings will be lower.

ElSherbini, A.; Maheshwari, G. P.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Metering Air Compressor Systems for Efficiency: A Progress Report  

E-Print Network (OSTI)

Air compressors have energy efficiency quantified as SCFM/BHP. However, this efficiency fluctuates over a broad range based on the loading of the compressor. When multiple compressors operate with varying loads, as in a central plant, the overall system efficiency is totally unknown. With funding from California Energy Commission under the PIER Program, we spent considerable effort over the past few years to develop system efficiency for air compressor central plants. The system efficiency was termed CASE Index, which varies from 0 to about 320, and has the units of SCF/KWH. The procedure we developed, involved metering of input (KWH) and output (SCFM), in and out of the central plant. After the initial beta testing of the procedure, as more and more compressor professionals started to use the procedure and as more metering equipments entered the picture, some metering complications were encountered. These problems were dealt with and the procedure developed under this project can produce reliable data. This paper also presents the system efficiencies we have recorded so far and the opportunities they indicate. The data shows a wide range, from a low 82 to about 250 on a 0 to 320 scale. This confirms our expectations of large energy efficiency improvement potential in compressed air systems.

Joseph, B.

2005-01-01T23:59:59.000Z

202

Fuel Cell Systems Sensors Air Management Benchmarking Modeling  

NLE Websites -- All DOE Office Websites (Extended Search)

Systems Systems F u e l P r o c e s s o r Sensors Air Management Benchmarking Modeling Patrick Davis Patrick Davis Targets and Status 50 kWe (net) Integrated Fuel Cell Power System 5000 2000 1000 Hours Durability 45 125 275 $/kW Cost (including H2 storage) 650 500 400 W/L Power density (w/o H2 stor) Operating on direct hydrogen 5000 2000 1000 Hours Durability 45 125 325 $/kW Cost 325 250 140 W/L Power density Operating on Tier 2 gasoline containing 30 ppm sulfur, average 2010 2005 2003 status Units Characteristics Projects Fuel Cell Power Systems Analysis ANL NREL TIAX Directed Technologies, Inc. TIAX TIAX * Fuel Cell Systems Analysis * Fuel Cell Vehicle Systems Analysis * Cost Analyses of Fuel Cell Stacks/ Systems * DFMA Cost Estimates of Fuel Cell/ Reformer Systems at Low, Medium, & High Production Rates * Assessment of Fuel Cell Auxiliary

203

Detailed Field Evaluation of a Cold Air Distribution System: Volumes 1 and 2  

Science Conference Proceedings (OSTI)

When following report recommendations, the system investigated in this study would provide significant energy consumption savings over conventional 55 degrees F supply air systems. Reduced duct size requirements, moreover, promise greater system design flexibility without sacrificing space comfort conditions or indoor air quality. Demonstrating the viability of cold air distribution systems, the report includes suggestions for improving system performance and overall efficiency.

1990-02-01T23:59:59.000Z

204

Identifying Efficiency Degrading Faults in Split Air Conditioning Systems  

E-Print Network (OSTI)

Studies estimate that as much as 50% of packaged air conditioning systems operate in faulty conditions that degrade system efficiency. Common faults include: under- and over-charged systems (too much or too little refrigerant), faulty expansions valves (stuck valves, valve hunting, poorly tuned valve controllers), and fouled evaporators and condensers. Furthermore, air conditioning systems can often be adjusted to improve efficiency while continuing to meet cooling loads (adjusting system pressures, decreasing superheat setpoints). This study presents the design of a low cost device that can non-invasively measure system operating conditions, diagnose faults, estimate potential energy savings, and provide recommendations on how the system should be adjusted or repaired. Using eight external temperature measurements, the device potentially can detect and diagnose up to ten faults commonly found in HVAC systems. Steady state temperatures are compared to threshold values obtained from literature and HVAC manufacturers to detect and determine the severity of faults and subsequent reductions in coefficient of performance. Preliminary tests reveal the potential for the device to detect and diagnose common efficiency-degrading faults in HVAC systems.

Terrill, T. J.; Brown, M. L.; Cheyne, R. W. Jr.; Cousins, A. J.; Daniels, B. P.; Erb, K. L.; Garcia, P. A.; Leutermann, M. J.; Nel, A. J.; Robert, C. L.; Widger, S. B.; Williams, A. G.; Rasmussen, B. P.

2013-01-01T23:59:59.000Z

205

High Technology Centrifugal Compressor for Commercial Air Conditioning Systems  

Science Conference Proceedings (OSTI)

R&D Dynamics, Bloomfield, CT in partnership with the State of Connecticut has been developing a high technology, oil-free, energy-efficient centrifugal compressor called CENVA for commercial air conditioning systems under a program funded by the US Department of Energy. The CENVA compressor applies the foil bearing technology used in all modern aircraft, civil and military, air conditioning systems. The CENVA compressor will enhance the efficiency of water and air cooled chillers, packaged roof top units, and other air conditioning systems by providing an 18% reduction in energy consumption in the unit capacity range of 25 to 350 tons of refrigeration The technical approach for CENVA involved the design and development of a high-speed, oil-free foil gas bearing-supported two-stage centrifugal compressor, CENVA encompassed the following high technologies, which are not currently utilized in commercial air conditioning systems: Foil gas bearings operating in HFC-134a; Efficient centrifugal impellers and diffusers; High speed motors and drives; and System integration of above technologies. Extensive design, development and testing efforts were carried out. Significant accomplishments achieved under this program are: (1) A total of 26 builds and over 200 tests were successfully completed with successively improved designs; (2) Use of foil gas bearings in refrigerant R134a was successfully proven; (3) A high speed, high power permanent magnet motor was developed; (4) An encoder was used for signal feedback between motor and controller. Due to temperature limitations of the encoder, the compressor could not operate at higher speed and in turn at higher pressure. In order to alleviate this problem a unique sensorless controller was developed; (5) This controller has successfully been tested as stand alone; however, it has not yet been integrated and tested as a system; (6) The compressor successfully operated at water cooled condensing temperatures Due to temperature limitations of the encoder, it could not be operated at air cooled condensing temperatures. (7) The two-stage impellers/diffusers worked well separately but combined did not match well.

Ruckes, John

2006-04-15T23:59:59.000Z

206

Monitoring System Used to Optimize Compressed Air System Efficiency, Cut Costs  

E-Print Network (OSTI)

In 1994, Thomson Consumer Electronics (RCA), an international manufacturer of electronics equipment purchased a UtillTRACK® Monitoring System for a plant in Indianapolis, Indiana. The system monitored gas and electric meters, substations, main feeders, and major equipment and systems including compressed air. For the compressed air system, monitored data included compressor amps, electrical demand and consumption, pressure and airflow. The resulting UtiliTRACK® reports and graphs showed a significant variation in system efficiency depending upon the demand for air (day of week, time of day, production schedule) and which compressor or compressors were operating. By working with the boiler plant operators and making minor modifications to the existing compressor controls, the operating sequence was modified to maintain high system efficiency under all operating conditions. Monitored data after the changes were made showed a 20% reduction in compressed air system operating costs.

Holmes, W. A.

1998-04-01T23:59:59.000Z

207

Propane gas: Handle with care  

SciTech Connect

Because of its chemical composition and combustion properties, this liquefied petroleum (LP) gas can be mixed with air and used as a direct replacement for natural gas with no burner or process equipment modifications. One major and growing use of propane is as a vehicle fuel. Growing industrial use of propane also has prompted the National Fire Protection Association (NFPA) to issue new codes. NFPA standard 58-95, Storing and Handling of Liquefied Petroleum Gases, stresses the need to adhere to safe work and handling practices whenever propane is involved. All employees directly handling the gas should be formally trained and certified, and recertified annually. Although the code applies only to those directly handling propane or operating propane equipment such as portable cylinder filling stations, all employees working around or with propane or other LP gases should understand the characteristics of LP gas and be aware of basic safe handling practices. The paper discusses what LP gas is, special safety concerns, the care required in refilling cylinders, and cylinder inspection.

Fernald, D. [Plant Systems, Inc., Berea, OH (United States)

1996-04-01T23:59:59.000Z

208

Modeling System Development for the Evaluation of Dynamic Air Quality  

NLE Websites -- All DOE Office Websites (Extended Search)

Modeling System Development for the Evaluation of Dynamic Air Quality Modeling System Development for the Evaluation of Dynamic Air Quality Impacts of DER Speaker(s): Robert Van Buskirk Date: January 30, 2003 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Kristina LaCommare A critical challenge for the atmospheric sciences is to understand the anthropogenic impacts on atmospheric chemistry over spatial scales ranging from the urban to the regional, and ultimately to the global, and over corresponding time scales ranging from minutes to weeks and ultimately annual trends. A similar challenge for energy policymakers is to integrate an understanding of impact dynamics into the economic dynamics of energy supply and demand. The challenges of dynamic analysis of emissions impacts from the energy sector have substantially increased with a new

209

D-Zero Instrument Air System Humidity Transmitter Evaluation  

SciTech Connect

This report shows the findings that resulted in the purchase of the optimum dew point hygrometer for use in the D-Zero instrument air system (see diagram 2 on page 9). The hygrometer will monitor the air syste m to insure that the dew point level does not go above the normal operating output of the driers (this precise value will be determined during initial system start-up). The following criteria was used in the evaluation: (1) Long term durability; (2) Minimum calibration; (3) Indicate a dew point level down to -40 C accurately; (4) Designed to work in a low humidity region; (5) Minimum maintenance; (6) Fast response time; and (7) Lowest cost provided all other criteria is met.

Serges, T.J.; /Fermilab

1988-07-15T23:59:59.000Z

210

Handling historical information on protected-area systems and coverage. An information system for the Natura 2000 European context  

Science Conference Proceedings (OSTI)

Protected-area coverage is an internationally-recognized surrogate indicator for measuring biodiversity conservation. To measure trends in biodiversity conservation over time, historical records on protected-area boundaries are needed. Protected-area ... Keywords: Biodiversity indicators, Conservation databases, Historical trends, Information systems (IS), Natura 2000, Protected areas, Protected-area boundaries, Protected-area coverage

Arnald Marcer; Víctor Garcia; Agustí Escobar; Xavier Pons

2010-08-01T23:59:59.000Z

211

Sensitivity of forced air distribution system efficiency to climate, duct location, air leakage and insulation  

E-Print Network (OSTI)

Location, Air Leakage and Insulation Iain S. Walker Energy4 Duct Insulation, Location and Leakageinsulation

Walker, Iain

2001-01-01T23:59:59.000Z

212

Liquid over-feeding air conditioning system and method  

DOE Patents (OSTI)

A refrigeration air conditioning system utilizing a liquid over-feeding operation is described. A liquid refrigerant accumulator-heat exchanger is placed in the system to provide a heat exchange relationship between hot liquid refrigerant discharged from condenser and a relatively cool mixture of liquid and vaporous refrigerant discharged from the evaporator. This heat exchange relationship substantially sub-cools the hot liquid refrigerant which undergoes little or no evaporation across the expansion device and provides a liquid over-feeding operation through the evaporator for effectively using 100 percent of evaporator for cooling purposes and for providing the aforementioned mixture of liquid and vaporous refrigerant. 1 figure.

Mei, V.C.; Chen, F.C.

1993-09-21T23:59:59.000Z

213

Liquid over-feeding air conditioning system and method  

DOE Patents (OSTI)

A refrigeration air conditioning system utilizing a liquid over-feeding operation is described. A liquid refrigerant accumulator-heat exchanger is placed in the system to provide a heat exchange relationship between hot liquid refrigerant discharged from condenser and a relatively cool mixture of liquid and vaporous refrigerant discharged from the evaporator. This heat exchange relationship substantially sub-cools the hot liquid refrigerant which undergoes little or no evaporation across the expansion device and provides a liquid over-feeding operation through the evaporator for effectively using 100 percent of evaporator for cooling purposes and for providing the aforementioned mixture of liquid and vaporous refrigerant.

Mei, Viung C. (Oak Ridge, TN); Chen, Fang C. (Knoxville, TN)

1993-01-01T23:59:59.000Z

214

Smart Operations of Air-Conditioning and Lighting Systems in Government Buildings for Peak Power Reduction  

E-Print Network (OSTI)

During the summer 2007 smart operation strategies for air-conditioning (A/C) and lighting systems were developed and tested in a number of governmental buildings in Kuwait as one of the solutions to reduce the national peak demand for electrical power that commonly occur around 15:00 h. The working hours for these building are generally between 07:00 and 14:00 h and their peak demand exceeds 600 MW. The smart operation strategies implemented in these buildings included pre-closing treatment (PCT) between 13:00 and 14:00 h and time-of-day control (TDC) after 14:00 h. Also de-lamping was carried out in some of the buildings to readjust the higher than recommended illumination levels. This paper presents the achievements of implementing these smart operations strategies in Justice Palace Complex (JPC) as a case study. The peak load of this building was 3700 kW. The achievements are summarized as an all time saving of 22 kW by de-lamping, an additional saving of 27 kW through TDC of lighting, direct savings between 13:00 and 22:00 h by closing supply and return air fans of 52 air-handling units with a connected load 400 kW, and an additional saving of 550 kW during the same period by optimizing the cooling production and distribution. In conclusion project achieved an overall reduction in power demand of around 20% between 13:00 to 17:00 h and reduction ranging from 7% to 15% between 17:00 to 20:00 h.

Al-Hadban, Y.; Maheshwari, G. P.; Al-Nakib, D.; Al-Mulla, A.; Alasseri, R.

2008-10-01T23:59:59.000Z

215

Incident Handling Activities  

Science Conference Proceedings (OSTI)

[an error occurred while processing this directive] Incident Handling Activities. Since 1989 the National Institute of Standards ...

216

Vacuum Vessel Remote Handling  

E-Print Network (OSTI)

FIRE Vacuum Vessel and Remote Handling Overview B. Nelson, T. Burgess, T. Brown, H-M Fan, G. Jones #12;13 July 2002 Snowmass Review: FIRE Vacuum Vessel and Remote Handling 2 Presentation Outline · Remote Handling - Maintenance Approach & Component Classification - In-Vessel Transporter - Component

217

Improving Energy Efficiency of Compressed Air System Based on System Audit  

E-Print Network (OSTI)

plan, formulate energy efficiency goals and adopt energyGO-102004-1926 [3] Energy Efficiency and Market Potential ofImproving Energy Efficiency of Compressed Air System Based

Shanghai, Hongbo Qin; McKane, Aimee

2008-01-01T23:59:59.000Z

218

TECHNOLOGY DEVELOPMENT AND DEPLOYMENT OF SYSTEMS FOR THE RETRIEVAL AND PROCESSING OF REMOTE-HANDLED SLUDGE FROM HANFORD K-WEST FUEL STORAGE BASIN  

SciTech Connect

In 2011, significant progress was made in developing and deploying technologies to remove, transport, and interim store remote-handled sludge from the 105-K West Fuel Storage Basin on the Hanford Site in south-central Washington State. The sludge in the 105-K West Basin is an accumulation of degraded spent nuclear fuel and other debris that collected during long-term underwater storage of the spent fuel. In 2010, an innovative, remotely operated retrieval system was used to successfully retrieve over 99.7% of the radioactive sludge from 10 submerged temporary storage containers in the K West Basin. In 2011, a full-scale prototype facility was completed for use in technology development, design qualification testing, and operator training on systems used to retrieve, transport, and store highly radioactive K Basin sludge. In this facility, three separate systems for characterizing, retrieving, pretreating, and processing remote-handled sludge were developed. Two of these systems were successfully deployed in 2011. One of these systems was used to pretreat knockout pot sludge as part of the 105-K West Basin cleanup. Knockout pot sludge contains pieces of degraded uranium fuel ranging in size from 600 {mu}m to 6350 {mu}m mixed with pieces of inert material, such as aluminum wire and graphite, in the same size range. The 2011 pretreatment campaign successfully removed most of the inert material from the sludge stream and significantly reduced the remaining volume of knockout pot product material. Removing the inert material significantly minimized the waste stream and reduced costs by reducing the number of transportation and storage containers. Removing the inert material also improved worker safety by reducing the number of remote-handled shipments. Also in 2011, technology development and final design were completed on the system to remove knockout pot material from the basin and transport the material to an onsite facility for interim storage. This system is scheduled for deployment in 2012. The prototype facility also was used to develop technology for systems to retrieve remote-handled transuranic sludge smaller than 6350 {mu}m being stored in underwater containers. After retrieving the sludge, the system will be used to load and transport the sludge for interim storage. During 2011, full-scale prototype systems were developed and tested to a Technology Readiness Level 6 as defined by U.S. Department of Energy standards. This system is scheduled for deployment in 2013. Operations also are scheduled for completion in 2014.

RAYMOND RE

2011-12-27T23:59:59.000Z

219

Hybrid membrane--PSA system for separating oxygen from air  

Science Conference Proceedings (OSTI)

A portable, non-cryogenic, oxygen generation system capable of delivering oxygen gas at purities greater than 98% and flow rates of 15 L/min or more is described. The system consists of two major components. The first component is a high efficiency membrane capable of separating argon and a portion of the nitrogen content from air, yielding an oxygen-enriched permeate flow. This is then fed to the second component, a pressure swing adsorption (PSA) unit utilizing a commercially available, but specifically formulated zeolite compound to remove the remainder of the nitrogen from the flow. The system is a unique gas separation system that can operate at ambient temperatures, for producing high purity oxygen for various applications (medical, refining, chemical production, enhanced combustion, fuel cells, etc . . . ) and represents a significant advance compared to current technologies.

Staiger, Chad L. (Albuquerque, NM); Vaughn, Mark R. (Albuquerque, NM); Miller, A. Keith (Albuquerque, NM); Cornelius, Christopher J. (Blackburg, VA)

2011-01-25T23:59:59.000Z

220

Residential Forced Air System Cabinet Leakage and Blower Performance  

E-Print Network (OSTI)

easy air sealing .such that the efficacy of air sealing is  determined by the inlet that prevents easy air sealing DeltaQ The DeltaQ test 

Walker, Iain S.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Residential Forced Air System Cabinet Leakage and Blower Performance  

E-Print Network (OSTI)

Residential ACM Manual, Section  3.12.5 Duct/Air Handler Residential ACM Manual, Section 3.12.5 Duct/Air  Handler leakage of air handlers for the purposes of the ACM.  Based 

Walker, Iain S.

2010-01-01T23:59:59.000Z

222

Residential Forced Air System Cabinet Leakage and Blower Performance  

E-Print Network (OSTI)

CA.   CEC (2008b).  Residential Alternative Calculation Standard for Air Handlers in Residential Space Conditioning of Standards Options for Residential Air Handler Fans.   

Walker, Iain S.

2010-01-01T23:59:59.000Z

223

Nuclear Maintenance Applications Center: Nuclear Fuel Handling Equipment Application and Maintenance Guide: Fuel Handling Equipment Guide  

Science Conference Proceedings (OSTI)

Fuel handling is a critical task during a nuclear power plant refueling outage. The proper operation of fuel handling equipment (such as fuel handling machines, fuel upending machines, fuel transfer carriages, and fuel elevators) is important to a successful refueling outage and to preparing fuel for eventual disposal.BackgroundThe fuel handling system contains the components used to move fuel from the time that the new fuel is received until the spent fuel ...

2013-12-13T23:59:59.000Z

224

Experimental Investigation on the Operation Performance of a Liquid Desiccant Air-conditioning System  

E-Print Network (OSTI)

A large share of energy consumption is taken by an air-conditioning system. It worsens the electricity load of the power network. Therefore, more and more scholars are paying attention to research on new types of air-conditioning systems that are energy- saving and environment-friendly. A liquid desiccant air conditioning system is among them, as it has a tremendous ability for power storage and low requirements for heat resources. Heat with low temperatures, such as excess heat, waste heat, and solar power, is suitable for the liquid desiccant air-conditioning system. The feasibility and economical efficiency of the system are studied in this experimental research. The result shows that when the temperature of the regeneration is about 80?, the thermodynamic coefficient of the system is about 0.6, and the supply air temperature of the air-conditioning system remains stable at 21?, the air-conditioning system can meet human comfort levels.

Liu, J.; Wang, J.; Wu, Z.; Gu, W.; Zhang, G.

2006-01-01T23:59:59.000Z

225

Energy studies on central and variable refrigerant flow air-conditioning systems  

Science Conference Proceedings (OSTI)

Air-conditioning is a major contributor to energy end-use in commercial buildings. Different types of airconditioning systems are installed in commercial buildings including packaged systems

2012-01-01T23:59:59.000Z

226

Sitraer 7 (2008) LXIV-LXXIV TECHNOLOGY ROADMAP FOR THE FUTURE AIR TRANSPORT SYSTEM  

E-Print Network (OSTI)

Sitraer 7 (2008) LXIV- LXXIV LXIV TECHNOLOGY ROADMAP FOR THE FUTURE AIR TRANSPORT SYSTEM BEING and the operation of aircraft within a future air transportation system achieving these objectives. The conclusion Universität Berlin Department of Aeronautics and Astronautics Chair of Flight Guidance and Air Transportation

Berlin,Technische Universität

227

Electrical applications for air conditioning and refrigeration systems  

Science Conference Proceedings (OSTI)

Electrical troubleshooting is possibly the most neglected area of maintaining air conditioning and refrigeration equipment. This text explains and illustrates methods for troubleshooting the full spectrum of electrical or electronic circuits of these systems. Comprehensive sections offer coverage of electrical fundamentals, single-phase electric motors, three-phase motors, control devices, electrical control circuits, use of schematic diagrams in troubleshooting, ice makers, solid state electronics, and basic electronic controls. The author`s clear, concise coverage of controls enables one to quickly understand both how a specific type of control works, and how it is used in the system. The reader will find a wealth of useful instructions for making operational checks and troubleshooting for proper operation. The book is conveniently divided into application-specific units, making it easy to quickly find information specific to a particular job at hand.

Langley, B.C.

1999-09-01T23:59:59.000Z

228

An Analysis of the Dynamics of the US Commercial Air Transportation System  

E-Print Network (OSTI)

Major trends in the airline industry are analyzed to highlight key dynamics that govern the US domestic air transportation system. The hypothesis is that air travel supply and demand equilibriums, a reliance on outside ...

Tam, Ryan

229

Air-Cooled Condensers in Next-Generation Conversion Systems Geothermal...  

Open Energy Info (EERE)

Air-Cooled Condensers in Next-Generation Conversion Systems Geothermal Lab Call Project Jump to: navigation, search Last modified on July 22, 2011. Project Title Air-Cooled...

230

Linking the Eta Model with the Community Multiscale Air Quality (CMAQ) Modeling System to Build a National Air Quality Forecasting System  

Science Conference Proceedings (OSTI)

NOAA and the U.S. Environmental Protection Agency (EPA) have developed a national air quality forecasting (AQF) system that is based on numerical models for meteorology, emissions, and chemistry. The AQF system generates gridded model forecasts ...

Tanya L. Otte; George Pouliot; Jonathan E. Pleim; Jeffrey O. Young; Kenneth L. Schere; David C. Wong; Pius C. S. Lee; Marina Tsidulko; Jeffery T. McQueen; Paula Davidson; Rohit Mathur; Hui-Ya Chuang; Geoff DiMego; Nelson L. Seaman

2005-06-01T23:59:59.000Z

231

Model Based Sensor System for Temperature Measurement in R744 Air Conditioning Systems  

E-Print Network (OSTI)

The goal is the development of a novel principle for the temperature acquisition of refrigerants in CO2 air conditioning systems. The new approach is based on measuring the temperature inside a pressure sensor, which is also needed in the system. On the basis of simulative investigations of different mounting conditions functional relations between measured and medium temperature will be derived.

Reitz, Sven; Schneider, Peter

2008-01-01T23:59:59.000Z

232

Enhancing CIMOSA with Exception Handling  

E-Print Network (OSTI)

CIMOSA (Open System Architecture for CIM) [2], an architecture for the modelling of manufacturing applications, does not provide a facility for exception definition and handling. Exceptions, traditionally associated to programming language and operating systems, are necessary in all types of languages, including specification languages. Our contribution consists of the enhancement of the CIMOSA model with a complete facility and methodology for the specification of the system behaviour in case of exception.

Messina Pleinevaux Swiss; S. Messina; P. Pleinevaux

1996-01-01T23:59:59.000Z

233

Compressed Air 101: Getting Compressed Air to Work  

E-Print Network (OSTI)

"Air compressors are a significant industrial energy user. Based on a survey (conducted by Oregon State University and the Bonneville Power Administration) of energy audit reports from 125 plants, air compressors account for roughly 10% of total plant energy use. Furthermore, air compression is inefficient with up to 95% of compressor power dissipated as heat. Thus even minor improvements in system operation, control strategies, and efficiency can yield large energy savings and significant non-energy or productivity benefits from reliable compressed air. Compressed air is often called the ""fourth utility"" in industrial facilities after electricity, natural gas, and water. It provides motive power for machinery, cooling, materials handling, and hand tools. It is a safe, flexible, and powerful resource, but one that is seldom run for low operating costs or best productivity. Learning the basics of compressed air systems represents the beginning of both reducing energy costs and enjoying the productive benefits of reliable compressed air. Compressed air management systems, including a system approach to managing demand, stabilizing pressure, reducing leaks and compressor controls, can allow the industrial end user to save 20% - 50% of their air compressor electricity usage. The monitoring capabilities of compressed air management systems provide a useful tool through power, pressure and flow trending to maintain both the energy savings and increased system reliability. More efficiently managed compressed air systems are less costly to maintain and have less impact on the environment. The most important issues of industrial compressed air in relation to energy efficiency and management are: 1. Compressed air is an essential industrial utility; 2. Compressing air is a fundamentally inefficient energy transformation process; 3. Optimal operation of compressed air systems in industrial plants is seldom a priority and adequate management infonnation is rare, resulting in negative impacts on production and even less efficiency."

Burke, J. J.; Bessey, E. G.

2003-05-01T23:59:59.000Z

234

A study of pressure losses in residential air distribution systems  

Science Conference Proceedings (OSTI)

An experimental study was conducted to evaluate the pressure drop characteristics of residential duct system components that are either not available or not thoroughly (sometimes incorrectly) described in existing duct design literature. The tests were designed to imitate cases normally found in typical residential and light commercial installations. The study included three different sizes of flexible ducts, under different compression configurations, splitter boxes, supply boots, and a fresh air intake hood. The experimental tests conformed to ASHRAE Standard 120P--''Methods of Testing to Determine Flow Resistance of HVAC Air Ducts and Fittings''. The flexible duct study covered compressibility and bending effects on the total pressure drop, and the results showed that the available published references tend to underestimate the effects of compression in flexible ducts that can increase pressure drops by up to a factor of nine. The supply boots were tested under different configurations including a setup where a flexible duct elbow connection was considered as an integral part of the supply boot. The supply boots results showed that diffusers can increase the pressure drop by up to a factor of two in exit fittings, and the installation configuration can increase the pressure drop by up to a factor of five. The results showed that it is crucial for designers and contractors to be aware of the compressibility effects of the flexible duct, and the installation of supply boots and diffusers.

Abushakra, Bass; Walker, Iain S.; Sherman, Max H.

2002-07-01T23:59:59.000Z

235

Analysis of Energy Saving in a Clean Room Air-conditioning System  

E-Print Network (OSTI)

To address the issue of the substantial energy cost and operating cost of an all-return air system for a clean room, we changed the former system to a 2nd return air system. With the newest building energy simulation program, Energy Plus, we simulated and compared the summer energy consuming conditions of the two systems. Results prove the superiority of the 2nd return air system, and the validity of the simulation. Also, the air system energy performance in summer was illustrated with typical meteorological hour-to-hour data.

Liu, S.; Liu, J.; Pei, J.; Wang, M.

2006-01-01T23:59:59.000Z

236

Solar liquid-desiccant air-conditioning system. Final report  

DOE Green Energy (OSTI)

A design for a closed, diurnal, intermittent absorption chiller for passive solar air-conditioning using liquid sorbents has been constructed and tested. LiBr-H/sub 2/O will not work with this design because of its low vapor pressure at the temperature available. The approach has possibilities using the 2 LiBr-ZrBr-CH/sub 3/OH or H/sub 2/O-NH/sub 3/ sorbent refrigerant pairs. The use of H/sub 2/O-NH/sub 3/ appears to be the better candidate because of the lower solution viscosity and less cycle weight, through tank volumes and collector requirements are similar. Further study of other refrigerant pairs such as S-Thiocyanate-ammonia is indicated, however, the difficulties encountered in construction and low potential coefficient of performance, and thus large collection area needed, makes commercialization of such a system doubtful in the foreseeable future.

Not Available

237

The Effect of Pressure Difference Control on Hydraulic Stability in a Variable Flow Air Conditioning System  

E-Print Network (OSTI)

This paper analyzes the effects of different pressure difference control methods on hydraulic stability in a variable flow air conditioning system when it is applied to different air conditioning water systems. According to control method and water system, it can be divided into direct return system pass-by control, direct return system terminal control, reversed return system pass-by control and reversed return system terminal control. The results indicate that reversed return system terminal control has the best hydraulic stability.

Zhang, Z.; Fu, Y.; Chen, Y.

2006-01-01T23:59:59.000Z

238

Smart Operations of Air-Conditioning and Lighting Systems in a Government Buildings for Peak Power Reduction  

E-Print Network (OSTI)

This paper presents the achievements of implementing smart operations strategies for air-conditioning (A/C) and lighting systems in Justice Palace Complex (JPC), Kuwait during the summer 2007. The peak load of this building was 3700 kW. The achievements are summarized as direct savings between 13:00 and 22:00 h by closing supply and return air fans of 52 air-handling units with a connected load 400 kW, and an additional saving of 550 kW during the same period by optimizing the cooling production and distribution. Also an all time saving of 22 kW by de-lamping, and additional saving of 27 kW through TDC of lighting were achieved. In conclusion project achieved an overall reduction in power demand of around 20% between 13:00 to 17:00 h and reduction ranging from 7% to 15% between 17:00 to 20:00 h.

Al-Hadban, Y.; Maheshwari, G. P.; Al-Nakib, D.; Al-Mulla, A.; Alasseri, R.

2010-01-01T23:59:59.000Z

239

A non-contact end-effector for the handling of garments  

Science Conference Proceedings (OSTI)

In order to handle a material with either a delicate surface or an air permeable structure, a novel nozzle was designed and developed. This nozzle utilises the phenomena of the radial air outflow. It is envisaged that this new nozzle will handle materials ... Keywords: End-effector, Fabric, Garment, Gripper, Handling

Babur Ozcelik; Fehmi Erzincanli

2002-07-01T23:59:59.000Z

240

An overview of solar assisted air-conditioning system application in small office buildings in Malaysia  

Science Conference Proceedings (OSTI)

In many regions of the world especially tropical weather in Malaysia, the demand for cooling of indoor air is growing due to increasing comfort expectations and increasing cooling loads. Air-conditioning, the most common cooling mechanism for providing ... Keywords: Malaysian climatic conditions, absorption chiller, evacuated tube solar collector, high energy consumption, peak load demand, solar assisted air conditioning system, solar energy

Lim Chin Haw; Kamaruzzaman Sopian; Yusof Sulaiman

2009-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

COMPRESSED-AIR ENERGY STORAGE SYSTEMS FOR STAND-ALONE OFF-GRID PHOTOVOLTAIC MODULES  

E-Print Network (OSTI)

-storage materials, flywheels, pumped hydro (PH), superconducting magnetic energy storage (SMES) and compressed airCOMPRESSED-AIR ENERGY STORAGE SYSTEMS FOR STAND-ALONE OFF-GRID PHOTOVOLTAIC MODULES Dominique, USA ABSTRACT In this work, a low-cost, low-volume, low-maintenance, small-scale compressed-air energy

Deymier, Pierre

242

Active improvement of air-conditioning system energy consumption with adaptive thermal comfort approach.  

E-Print Network (OSTI)

??The MSc research project aims to suggest improvements to building air-conditioning control systems, to reduce energy consumption while maintaining the comfort level of the occupants.… (more)

Muhammad Saleh, Muhammad Fadzli

2013-01-01T23:59:59.000Z

243

Superheat control for air conditioning and refrigeration systems: Simulation and experiments.  

E-Print Network (OSTI)

??Ever since the invention of air conditioning and refrigeration in the late nineteenth century, there has been tremendous interest in increasing system efficiency to reduce… (more)

Otten, Richard J.

2010-01-01T23:59:59.000Z

244

Dynamic modeling and global optimal operation of multizone variable air volume HVAC systems.  

E-Print Network (OSTI)

??Energy conservation and indoor environment concerns have motivated extensive research on various aspects of control of Heating, Ventilating and Air-Conditioning (HVAC) and building systems. The… (more)

Zheng, Guo Rong

1997-01-01T23:59:59.000Z

245

Analysis of the Energy Consumption of VAV System in Different Supply Air Control Strategies  

Science Conference Proceedings (OSTI)

Variable air volume (VAV) system has been widely applied due to its characteristics of eminent energy saving and thermal comfort. Because of its above characteristics, sophisticated automatic control systems are required to support its operation. While ... Keywords: VAV A/C system, supply air control strategy, energy consumption analysis

Junjie Guo, Xiangxin Cheng

2012-07-01T23:59:59.000Z

246

2010 Manufacturing Readiness Assessment Update to the 2008 Report for Fuel Cell Stacks and Systems for the Backup Power and Material Handling Equipment Markets  

NLE Websites -- All DOE Office Websites (Extended Search)

Manufacturing Readiness Manufacturing Readiness Assessment Update to the 2008 Report for Fuel Cell Stacks and Systems for the Backup Power and Material Handling Equipment Markets Doug Wheeler DJW Technology Michael Ulsh National Renewable Energy Laboratory Technical Report NREL/TP-5600-53046 August 2012 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 15013 Denver West Parkway Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308 2010 Manufacturing Readiness Assessment Update to the 2008 Report for Fuel Cell Stacks and Systems for the Backup Power

247

Heat transfer pathways in underfloor air distribution (UFAD) systems  

E-Print Network (OSTI)

displacement venti- lation. ASHRAE Transactions 105(1):298–309. ASHRAE Transactionsunderfloor air supply plenums. ASHRAE Trans- actions 112(2).

Bauman, F.; Jin, H.; Webster, T.

2006-01-01T23:59:59.000Z

248

Environmental policymaking for air transportation : toward an emissions trading system.  

E-Print Network (OSTI)

??Aviation is at a turning point. Considerable improvements in aircraft emissions efficiencies are expected through technological improvements, air traffic management, and managerial strategies. But global… (more)

De Serres, Martine.

2007-01-01T23:59:59.000Z

249

Simulation of energy performance of underfloor air distribution (UFAD) systems  

E-Print Network (OSTI)

energy consumption and the peak demand were calculated usingand also in the reduction of peak demand HVAC annual energymeasure to reduce peak demand. Key words Underfloor air

2009-01-01T23:59:59.000Z

250

Air source heat pump system for drying application  

Science Conference Proceedings (OSTI)

This paper investigates the performance of an air source heat pump for drying purpose. In order to evaluate the performance analysis; a simulation study has been done. The results of simulation of heat pump dryer for different evaporator temperatures ... Keywords: air source heat pump, coefficient of performance (COP), condenser temperature and compressor work, dryer, evaporator temperature

R. Daghigh; M. H. Ruslan; A. Zaharim; K. Sopian

2010-10-01T23:59:59.000Z

251

Fault Diagnosis of an Air-Conditioning System Using LS-SVM  

Science Conference Proceedings (OSTI)

This paper describes fault diagnosis of an air-conditioning system for improving reliability and guaranteeing the thermal comfort and energy saving. To achieve this goal, we proposed a technique which is model based fault diagnosis technique. Here, a ... Keywords: Air-Conditioning System, FDD, LS-SVM, Residuals generator

Mahendra Kumar; I. N. Kar

2009-12-01T23:59:59.000Z

252

Impact of the Variable Refrigerant Volume Air Conditioning System on Building Energy Efficiency  

E-Print Network (OSTI)

The application of the variable refrigerant volume multi-zone air conditioning systems has met with mixed results since the publication of the Design Standard for Energy Efficiency of Public Buildings. This paper analyzes the characteristics of the variable refrigerant volume multi-zone air conditioning system, and discusses the advantages of its application.

Zhu, H.

2006-01-01T23:59:59.000Z

253

A Computer-Controlled Continuous Air Drying and Flask Sampling System  

Science Conference Proceedings (OSTI)

A computer-controlled continuous air drying and flask sampling system has been developed and is discussed here. This system is set up for taking air samples automatically at remote places. Twenty glass flasks can be connected one by one or in ...

R. E. M. Neubert; L. L. Spijkervet; J. K. Schut; H. A. Been; H. A. J. Meijer

2004-04-01T23:59:59.000Z

254

Intelligent Residential Air-Conditioning System with Smart-Grid Functionality  

E-Print Network (OSTI)

1 Intelligent Residential Air-Conditioning System with Smart-Grid Functionality Auswin George residential air-conditioning (A/C) system controller that has smart grid functionality. The qualifier, conditional on anticipated retail energy prices. The term "smart- grid functionality" means that retail energy

Tesfatsion, Leigh

255

Air Distribution Systems and Cross-Infection Risk in the Hospital Sector  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Distribution Systems and Cross-Infection Risk in the Hospital Sector Air Distribution Systems and Cross-Infection Risk in the Hospital Sector Speaker(s): Peter V. Nielsen Date: November 28, 2012 - 12:00pm Location: 90-4133 Seminar Host/Point of Contact: Rongxin Yin We protect ourselves from airborne cross-infection in the indoor environment by supplying fresh air to the room by natural or mechanical ventilation. The air is distributed in the room according to different principles as e.g. mixing ventilation, downward ventilation, displacement ventilation, etc. A large amount of air is supplied to the room to ensure dilution of airborne infection. The talk discusses both the macroenvironment and the microenvironment. The macroenvironment is the conditions created by the air distribution system, and the microenvironment is the conditions created by the local flow around persons in combination

256

Register Closing Effects on Forced Air Heating System Performance  

E-Print Network (OSTI)

Air Handler Power - Climate Zone 16 48 hr avg 24 hr avg FarAverage Gas Power - Climate Zone 16 48 hr avg 24 hr avg NearAverage Gas Power - Climate Zone 16 48 hr avg Near Registers

Walker, Iain S.

2003-01-01T23:59:59.000Z

257

Air cooled turbine component having an internal filtration system  

DOE Patents (OSTI)

A centrifugal particle separator is provided for removing particles such as microscopic dirt or dust particles from the compressed cooling air prior to reaching and cooling the turbine blades or turbine vanes of a turbine engine. The centrifugal particle separator structure has a substantially cylindrical body with an inlet arranged on a periphery of the substantially cylindrical body. Cooling air enters centrifugal particle separator through the separator inlet port having a linear velocity. When the cooling air impinges the substantially cylindrical body, the linear velocity is transformed into a rotational velocity, separating microscopic particles from the cooling air. Microscopic dust particles exit the centrifugal particle separator through a conical outlet and returned to a working medium.

Beeck, Alexander R. (Orlando, FL)

2012-05-15T23:59:59.000Z

258

Air Pollution Control Systems for Stack and Process Emissions  

Science Conference Proceedings (OSTI)

Strict environmental regulations at the federal and local levels require that industrial facilities control emissions of particulates, nitrogen oxides (NOx), sulfur dioxide (SO2), volatile organic compounds (VOCs), and hazardous air pollutants. To comply with regulations, industries must either modify the processes or fuels they use to limit the generation of air pollutants, or remove the pollutants from the process gas streams before release into the atmosphere. This report provides a comprehensive disc...

2001-03-30T23:59:59.000Z

259

Test and Reconstruction of Air Conditioning System in a Hotel Lobby  

E-Print Network (OSTI)

Two air conditioning systems are equipped in a hotel lobby. It is found from the field test that the actual air rate is 40% and 16% of the nominal value, respectively, of the two systems, which is far lower than the design requirement. The air rate of the outlets varies greatly, and the coefficient of uniformity is 129.1% and 111.6% respectively of the two systems. Air distribution in the lobby is bad and thermal comfort is poor. Moreover, sharp reduction of return air makes portions of fresh air increase, which will lead to high energy consumption. Reconstruction is carried out to improve the thermal environment with the assistance of the CFD method. First, the original system is simulated by CFD method to verify the CFD method and propose modification suggestions. Then air conditioning load and air rate of the lobby is recalculated and duct redesigned. Simulation results show that the air distribution and thermal comfort of the improved scheme can meet the design requirement. The reconstructed system has been running for about two years and has shown good performance.

Wang, G.; Hu, Y.; Hu, S.; Chen, Q.

2006-01-01T23:59:59.000Z

260

Energy and economic assessment of desiccant cooling systems coupled with single glazed air and hybrid PV/thermal solar collectors for applications in hot and humid climate  

SciTech Connect

This paper presents a detailed analysis of the energy and economic performance of desiccant cooling systems (DEC) equipped with both single glazed standard air and hybrid photovoltaic/thermal (PV/t) collectors for applications in hot and humid climates. The use of 'solar cogeneration' by means of PV/t hybrid collectors enables the simultaneous production of electricity and heat, which can be directly used by desiccant air handling units, thereby making it possible to achieve very energy savings. The present work shows the results of detailed simulations conducted for a set of desiccant cooling systems operating without any heat storage. System performance was investigated through hourly simulations for different systems and load combinations. Three configurations of DEC systems were considered: standard DEC, DEC with an integrated heat pump and DEC with an enthalpy wheel. Two kinds of building occupations were considered: office and lecture room. Moreover, three configurations of solar-assisted air handling units (AHU) equipped with desiccant wheels were considered and compared with standard AHUs, focusing on achievable primary energy savings. The relationship between the solar collector's area and the specific primary energy consumption for different system configurations and building occupation patterns is described. For both occupation patterns, sensitivity analysis on system performance was performed for different solar collector areas. Also, this work presents an economic assessment of the systems. The cost of conserved energy and the payback time were calculated, with and without public incentives for solar cooling systems. It is worth noting that the use of photovoltaics, and thus the exploitation of related available incentives in many European countries, could positively influence the spread of solar air cooling technologies (SAC). An outcome of this work is that SAC systems equipped with PV/t collectors are shown to have better performance in terms of primary energy saving than conventional systems fed by vapour compression chillers and coupled with PV cells. All SAC systems present good figures for primary energy consumption. The best performances are seen in systems with integrated heat pumps and small solar collector areas. The economics of these SAC systems at current equipment costs and energy prices are acceptable. They become more interesting in the case of public incentives of up to 30% of the investment cost (Simple Payback Time from 5 to 10 years) and doubled energy prices. (author)

Beccali, Marco; Finocchiaro, Pietro; Nocke, Bettina [Universita degli Studi di Palermo, Palermo (Italy)

2009-10-15T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

FUEL HANDLING MECHANISM  

DOE Patents (OSTI)

A remotely operable handling device specifically adapted for the handling of vertically disposed fuel rods in a nuclear reactor was developed. The device consists essentially of an elongated tubular member having a gripping device at the lower end of the pivoted jaw type adapted to grip an enlarged head on the upper end of the workpiece. The device includes a sensing element which engages the enlarged head and is displaced to remotely indicate when the workpiece is in the proper position to be engaged by the jaws.

Koch, L.J.; Hutter, E.

1960-02-01T23:59:59.000Z

262

SLUG HANDLING DEVICES  

DOE Patents (OSTI)

A device is described for handling fuel elements of a neutronic reactor. The device consists of two concentric telescoped contalners that may fit about the fuel element. A number of ratchet members, equally spaced about the entrance to the containers, are pivoted on the inner container and spring biased to the outer container so thnt they are forced to hear against and hold the fuel element, the weight of which tends to force the ratchets tighter against the fuel element. The ratchets are released from their hold by raising the inner container relative to the outer memeber. This device reduces the radiation hazard to the personnel handling the fuel elements.

Gentry, J.R.

1958-09-16T23:59:59.000Z

263

An inlet air washer/chiller system for combined cycle planet repowering  

Science Conference Proceedings (OSTI)

A conditioning method to achieve increased output at any relative humidity condition is an air washer and absorption chiller arrangement. At elevated temperatures and low humidity, the air washer operates as an evaporative cooler without the chiller in operation. In this mode, the air washer will give similar results as a media type evaporative cooler at a fraction of the pressure loss. In the air washer plus chiller operating mode the chiller maintains cooling effectiveness of the air washer during periods of high relative humidity. This makes such a system very appropriate anywhere relative humidity is high. Many combined cycle plants utilize supplemental firing of the heat recovery steam generators to offset the loss of gas turbine power at high ambient temperatures. This paper shows that in contrast to supplementary firing, the combination air washer/chiller system can generate power more efficiently and at lower cost.

Sengupta, U.; Soroka, G. (Bechtel Power Corp., Gaithersburg, MD (USA))

1989-01-01T23:59:59.000Z

264

Assessment of Advanced Air Purification Technologies: Filtration and Hybrid Systems for Residential and Commercial Applications  

Science Conference Proceedings (OSTI)

Indoor air contaminants, such as microorganisms, allergens, environmental tobacco smoke, and volatile organic compounds, can cause health- and productivity-related problems for the occupants of the indoor space. Children, elderly adults, and people with deficient immune systems are especially likely to be affected by contaminated air. There are three primary measures to control indoor air contamination. The first is to eliminate the contaminant source. The second is to control ventilation within the spac...

2003-01-20T23:59:59.000Z

265

Oxygen Handling and Cooling Options in High Temperature Electrolysis Plants  

DOE Green Energy (OSTI)

Idaho National Laboratory is working on a project to generate hydrogen by high temperature electrolysis (HTE). In such an HTE system, safety precautions need to be taken to handle high temperature oxygen at ~830°C. This report is aimed at addressing oxygen handling in a HTE plant.. Though oxygen itself is not flammable, most engineering material, including many gases and liquids, will burn in the presence of oxygen under some favorable physicochemical conditions. At present, an absolute set of rules does not exist that can cover all aspects of oxygen system design, material selection, and operating practices to avoid subtle hazards related to oxygen. Because most materials, including metals, will burn in an oxygen-enriched environment, hazards are always present when using oxygen. Most materials will ignite in an oxygen-enriched environment at a temperature lower than that in air, and once ignited, combustion rates are greater in the oxygen-enriched environment. Even many metals, if ignited, burn violently in an oxygen-enriched environment. However, these hazards do not preclude the operations and systems involving oxygen. Oxygen can be safely handled and used if all the materials in a system are not flammable in the end-use environment or if ignition sources are identified and controlled. In fact, the incidence of oxygen system fires is reported to be low with a probability of about one in a million. This report is a practical guideline and tutorial for the safe operation and handling of gaseous oxygen in high temperature electrolysis system. The intent is to provide safe, practical guidance that permits the accomplishment of experimental operations at INL, while being restrictive enough to prevent personnel endangerment and to provide reasonable facility protection. Adequate guidelines are provided to govern various aspects of oxygen handling associated with high temperature electrolysis system to generate hydrogen. The intent here is to present acceptable oxygen standards and practices for minimum safety requirements. A summary of operational hazards, along with oxygen safety and emergency procedures, are provided.

Manohar S. Sohal; J. Stephen Herring

2008-07-01T23:59:59.000Z

266

Economic Analysis of a Waste Water Resource Heat Pump Air-Conditioning System in North China  

E-Print Network (OSTI)

This paper describes the situation of waste water resource in north China and the characteristics and styles of a waste water resource heat pump system, and analyzes the economic feasibility of a waste water resource heat pump air-conditioning system including investment, operating fee and pay-back time. The results show that waste water resource heat pump air-conditioning system has a low investment, low operating fee and short payback time.

Chen, H.; Li, D.; Dai, X.

2006-01-01T23:59:59.000Z

267

Solar air conditioning system using desiccant wheel technology  

Science Conference Proceedings (OSTI)

The electrical energy consumption in Malaysia has increased sharply in the past few years. Modern energy efficient technologies are desperately needed for the national energy policy. In this paper, a new design of desiccant cooling is being developed ... Keywords: air-conditioning, desiccant cooling, solar thermal energy, solid desiccant

Arfidian Rachman; Sohif Mat; Taib Iskandar; M. Yahya; Azami Zaharim; Kamaruzzaman Sopian

2010-10-01T23:59:59.000Z

268

Measure Guideline: Air Sealing Mechanical Closets in Slab-On-Grade Homes  

Science Conference Proceedings (OSTI)

This measure guideline describes covers two fundamental retrofit strategies for air sealing around air handling systems that are located within the living space in an enclosed closet: one in which all of the equipment is removed and being replaced, and a closet where the equipment is to remain and existing conditions are sealed. It includes the design and installation details necessary to effectively seal the air handler closet and central return system to maximize the efficiency and safety of the space conditioning system.

Dickson, B.

2012-02-01T23:59:59.000Z

269

Numerical simulation of hydraulic shock in a water pumping system protected by air  

Science Conference Proceedings (OSTI)

Air may be efficiently used in water pumping system protection from hydraulic shock, due to its elasticity. The paper presents the results regarding the extreme pressures in the discharge duct of a pumping installation, obtained by numerical simulation ... Keywords: air chamber, biphasic flow, dissolution, hydraulic shock, pumping installation

Anca Constantin; Claudiu Stefan Nitescu

2010-10-01T23:59:59.000Z

270

Performance simulation of R410A air conditioning system with variable speeds  

Science Conference Proceedings (OSTI)

With the implementation of "Montreal protocol on substances that deplete the ozone layer", HCFCs especially R22 will be phased out. R410A (R32/R125,50/50wt%), as one alternative of R22, is a promising refrigerant for air conditioning ... Keywords: R410A, air conditioning, electronic expansion valve, performance, refrigerants, system simulation, variable speeds

Zaoxiao Zhang; Yongzhang Yu; Leping Zhang

2004-12-01T23:59:59.000Z

271

MAQS: a personalized mobile sensing system for indoor air quality monitoring  

Science Conference Proceedings (OSTI)

Most people spend more than 90% of their time indoors; indoor air quality (IAQ) influences human health, safety, productivity, and comfort. This paper describes MAQS, a personalized mobile sensing system for IAQ monitoring. In contrast with existing ... Keywords: air quality sensing, location based service, smartphone

Yifei Jiang; Kun Li; Lei Tian; Ricardo Piedrahita; Xiang Yun; Omkar Mansata; Qin Lv; Robert P. Dick; Michael Hannigan; Li Shang

2011-09-01T23:59:59.000Z

272

Testing and evaluation aspects of integration of unmanned air systems into the national air space  

Science Conference Proceedings (OSTI)

Current developments show that the integration of Unmanned Aerial Systems (UAS) into the National Airspace System (NAS) is a process that will inevitably happen. Arguably, it may be viewed as one of the key milestones in the history of aviation. Whereas ... Keywords: NAS integration, modeling and simulation, test and evaluation, unmanned aerial systems, verification and validation

Mauricio Castillo-Effen; Nikita Visnevski

2010-09-01T23:59:59.000Z

273

Residential Forced Air System Cabinet Leakage and Blower Performance  

E-Print Network (OSTI)

in Residential Space Conditioning  Systems.   Canadian in residential space conditioning systems”.   Keywords: in residential space conditioning systems”. This standard

Walker, Iain S.

2010-01-01T23:59:59.000Z

274

Hybrid membrane--PSA system for separating oxygen from air ...  

The system is a unique gas separation system that ... Energy Innovation ... Sandia National Laboratories - Visit the Intellectual Property Management and ...

275

Comparative Study Between Air-Cooled and Water-Cooled Condensers of the Air-Conditioning Systems  

E-Print Network (OSTI)

The weather in Kuwait is very dry where the dry-bulb temperature exceeds the wet-bulb temperature more than 20oC in most of the summer months. Thus, the air-conditioning (A/C) system with the water-cooled (WC) condensers is expected to perform more efficiently than with the air-cooled (AC) condensers. This fact was behind the idea of a field study conducted in one of the major hospital in Kuwait during a summer season to investigate the performance of WC and AC systems in terms of peak power and energy consumptions. The cooling capacities for WC and AC systems were 373 and 278 tons-of- refrigeration, respectively. It was found that for the same cooling production, the peak power demand and the daily energy consumption of the WC system were 45 and 32% less than that of the AC system, respectively. The maximum reduction in the power demand coincided with the peak power demand period of the utilities i.e. between 14:00 and 17:00 hr, thereby offering a maximum advantage of peak power saving.

Maheshwari, G. P.; Mulla Ali, A. A.

2004-01-01T23:59:59.000Z

276

Recommendations for cask features for robotic handling from the Advanced Handling Technology Project  

SciTech Connect

This report describes the current status and recent progress in the Advanced Handling Technology Project (AHTP) initiated to explore the use of advanced robotic systems and handling technologies to perform automated cask handling operations at radioactive waste handling facilities, and to provide guidance to cask designers on the impact of robotic handling on cask design. Current AHTP tasks have developed system mock-ups to investigate robotic manipulation of impact limiters and cask tiedowns. In addition, cask uprighting and transport, using computer control of a bridge crane and robot, were performed to demonstrate the high speed cask transport operation possible under computer control. All of the current AHTP tasks involving manipulation of impact limiters and tiedowns require robotic operations using a torque wrench. To perform these operations, a pneumatic torque wrench and control system were integrated into the tool suite and control architecture of the gantry robot. The use of captured fasteners is briefly discussed as an area where alternative cask design preferences have resulted from the influence of guidance for robotic handling vs traditional operations experience. Specific robotic handling experiences with these system mock-ups highlight a number of continually recurring design principles: (1) robotic handling feasibility is improved by mechanical designs which emphasize operation with limited dexterity in constrained workspaces; (2) clearances, tolerances, and chamfers must allow for operations under actual conditions with consideration for misalignment and imprecise fixturing; (3) successful robotic handling is enhanced by including design detail in representations for model-based control; (4) robotic handling and overall quality assurance are improved by designs which eliminate the use of loose, disassembled parts. 8 refs., 15 figs.

Drotning, W.

1991-02-01T23:59:59.000Z

277

Analytical modeling of a hydraulically-compensated compressed-air energy-storage system  

Science Conference Proceedings (OSTI)

A computer program was developed to calculate the dynamic response of a hydraulically-compensated compressed air energy storage (CAES) system, including the compressor, air pipe, cavern, and hydraulic compensation pipe. The model is theoretically based on the two-fluid model in which the dynamics of each phase are presented by its set of conservation equations for mass and momentum. The conservation equations define the space and time distribution of pressure, void fraction, air saturation, and phase velocities. The phases are coupled by two interface equations. The first defines the rate of generation (or dissolution) of gaseous air in water and can include the effects of supersaturation. The second defines the frictional shear coupling (drag) between the gaseous air and water as they move relative to each other. The relative motion of the air and water is, therefore, calculated and not specified by a slip or drift-velocity correlation. The total CASE system is represented by a nodal arrangement. The conservation equations are written for each nodal volume and are solved numerically. System boundary conditions include the air flow rate, atmospheric pressure at the top of the compensation pipe, and air saturation in the reservoir. Initial conditions are selected for velocity and air saturation. Uniform and constant temperature (60/sup 0/F) is assumed. The analytical model was used to investigate the dynamic response of a proposed system.Investigative calculations considered high and low water levels, and a variety of charging and operating conditions. For all cases investigated, the cavern response to air-charging, was a damped oscillation of pressure and flow. Detailed results are presented. These calculations indicate that the Champagne Effect is unlikely to cause blowout for a properly designed CAES system.

McMonagle, C.A.; Rowe, D.S.

1982-12-01T23:59:59.000Z

278

Engineering Design Example CompressedCompressed--Air System for a Manufacturing PlantAir System for a Manufacturing Plant  

E-Print Network (OSTI)

to operate C/A tools: Compressor and piping layoutCompressor and piping layout Air supply circumferentially: · Estimate the load [cfm] based on current and future demand. · Size the compressor(s). · Size the pipes so*1.35=1900 cfm. · Centrifugal or reciprocating compressor may be chosen (later). From handbooks: P kk /)1

Kostic, Milivoje M.

279

A Field Air-Exclusion System for Measuring the Effects of Air Pollutants on Crops  

Science Conference Proceedings (OSTI)

In two years of field testing, an electronically regulated prototype proved more realistic for southwestern conditions than conventional systems for exposing plants to controlled amounts of pollutants. A mobile version of the experimental system, developed on the basis of the test results, is transportable to remote sites.

1985-08-12T23:59:59.000Z

280

Promising future energy storage systems: Nanomaterial based systems, Zn-air and electromechanical batteries  

SciTech Connect

Future energy storage systems will require longer shelf life, higher duty cycles, higher efficiency, higher energy and power densities, and be fabricated in an environmentally conscious process. This paper describes several possible future systems which have the potential of providing stored energy for future electric and hybrid vehicles. Three of the systems have their origin in the control of material structure at the molecular level and the subsequent nanoengineering into useful device and components: aerocapacitors, nanostructure multilayer capacitors, and the lithium ion battery. The zinc-air battery is a high energy density battery which can provide vehicles with long range (400 km in autos) and be rapidly refueled with a slurry of zinc particles and electrolyte. The electromechanical battery is a battery-sized module containing a high-speed rotor integrated with an iron-less generator mounted on magnetic bearings and housed in an evacuated chamber.

Koopman, R.; Richardson, J.

1993-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Air-Cooled Condensers in Next-Generation Conversion Systems Geothermal Lab  

Open Energy Info (EERE)

Air-Cooled Condensers in Next-Generation Conversion Systems Geothermal Lab Air-Cooled Condensers in Next-Generation Conversion Systems Geothermal Lab Call Project Jump to: navigation, search Last modified on July 22, 2011. Project Title Air-Cooled Condensers in Next-Generation Conversion Systems Project Type / Topic 1 Laboratory Call for Submission of Applications for Research, Development and Analysis of Geothermal Technologies Project Type / Topic 2 Air-Cooling Project Description As the geothermal industry moves to use geothermal resources that are more expensive to develop, there will be increased incentive to use more efficient power plants. Because of increasing demand on finite supplies of water, this next generation of more efficient plants will likely need to reject heat sensibly to the ambient (air-cooling). This will be especially true in western states having higher grade Enhanced Geothermal Systems (EGS) resources, as well as most hydrothermal resources. If one had a choice, an evaporative heat rejection system would be selected because it would provide both cost and performance advantages. The evaporative system, however, consumes a significant amount of water during heat rejection that would require makeup. Though they use no water, air-cooling systems have higher capital costs, reduced power output (heat is rejected at a higher temperature), lower power sales due to higher parasitics (fan power), and greater variability in power output (because of large variation in the dry-bulb temperature).

282

Modeling Air–Land–Sea Interactions Using the Integrated Regional Model System in Monterey Bay, California  

Science Conference Proceedings (OSTI)

The air–land–sea interaction in the vicinity of Monterey Bay, California, is simulated and investigated using a new Integrated Regional Model System (I-RMS). This new model realistically resolves coastal processes and submesoscale features that ...

Yu-Heng Tseng; Shou-Hung Chien; Jiming Jin; Norman L. Miller

2012-04-01T23:59:59.000Z

283

Air Distribution Systems and Cross-Infection Risk in the Hospital...  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Distribution Systems and Cross-Infection Risk in the Hospital Sector Speaker(s): Peter V. Nielsen Date: November 28, 2012 - 12:00pm Location: 90-4133 Seminar HostPoint of...

284

Avionics and control system development for mid-air rendezvous of two unmanned aerial vehicles  

E-Print Network (OSTI)

A flight control system was developed to achieve mid-air rendezvous of two unmanned aerial vehicles (UAVs) as a part of the Parent Child Unmanned Aerial Vehicle (PCUAV) project at MIT and the Draper Laboratory. A lateral ...

Park, Sanghyuk, 1973-

2004-01-01T23:59:59.000Z

285

A Comparative Study for the Air Distribution System of a Cleanroom...  

NLE Websites -- All DOE Office Websites (Extended Search)

A Comparative Study for the Air Distribution System of a Cleanroom with High Cooling Load and Airborne Molecular Sources Speaker(s): Shih-Cheng Hu Date: June 20, 2008 - 12:00pm...

286

Complexity within the Air Force acquisition system gaining insight from a theory of collapse  

E-Print Network (OSTI)

Joseph Tainter's theory of societal collapse is applied in an examination of the U.S. Air Force's aircraft acquisition system in order to gain insight into the enterprise's lagging performance. Theories of collapse at both ...

Marticello, Daniel Nicholas, Jr

2012-01-01T23:59:59.000Z

287

Analysis of a Retrofitted Thermal Energy Storage Air-conditioning System of a Marine Museum.  

E-Print Network (OSTI)

??Thermal energy storage(TES) air-conditioning system is a electrical load management technology with great potential to shift load from peak to off-peak utility periods. TES is… (more)

Yu, Po-wen

2005-01-01T23:59:59.000Z

288

Energy Department Releases Study of Electricity System Ahead of Proposed EPA Air Quality Standards  

Energy.gov (U.S. Department of Energy (DOE))

In anticipation of forthcoming Environmental Protection Agency proposals for clean air standards, DOE released a new report examining the potential impact those proposed standards could have on the reliability of our nation’s energy systems.

289

2010 Manufacturing Readiness Assessment Update to the 2008 Report for Fuel Cell Stacks and Systems for the Backup Power and Materials Handling Equipment Markets  

DOE Green Energy (OSTI)

In 2008, the National Renewable Energy Laboratory (NREL), under contract to the US Department of Energy (DOE), conducted a manufacturing readiness assessment (MRA) of fuel cell systems and fuel cell stacks for back-up power and material handling applications (MHE). To facilitate the MRA, manufacturing readiness levels (MRL) were defined that were based on the Technology Readiness Levels previously established by the US Department of Energy (DOE). NREL assessed the extensive existing hierarchy of MRLs developed by Department of Defense (DoD) and other Federal entities, and developed a MRL scale adapted to the needs of the Fuel Cell Technologies Program (FCTP) and to the status of the fuel cell industry. The MRL ranking of a fuel cell manufacturing facility increases as the manufacturing capability transitions from laboratory prototype development through Low Rate Initial Production to Full Rate Production. DOE can use MRLs to address the economic and institutional risks associated with a ramp-up in polymer electrolyte membrane (PEM) fuel cell production. In 2010, NREL updated this assessment, including additional manufacturers, an assessment of market developments since the original report, and a comparison of MRLs between 2008 and 2010.

Wheeler, D.; Ulsh, M.

2012-08-01T23:59:59.000Z

290

A Comparative Study for the Air Distribution System of a Cleanroom with  

NLE Websites -- All DOE Office Websites (Extended Search)

A Comparative Study for the Air Distribution System of a Cleanroom with A Comparative Study for the Air Distribution System of a Cleanroom with High Cooling Load and Airborne Molecular Sources Speaker(s): Shih-Cheng Hu Date: June 20, 2008 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Tim Xu With rapid change of production line in Taiwan IT Industries; increased productivity/flexibility in the same cleanroom space is required urgently. We have systematically compared two cleanroom ventilation systems i.e. conventional and ceiling return system. The wall return system has fixed location of Fan filter unit (FFU), return air shaft/wall and dry coiling coil. The ceiling return system with a specially designed Fan Filter Dry Coil Unit (FFDCU) installed just above a production tool with high heat/particle sources. For a wall return system, reduced flexibility and

291

Effect of a Radiant Panel Cooling System on Indoor Air Quality of a Conditioned Space  

E-Print Network (OSTI)

This paper discusses the effect of a radiant cooling panel system on an indoor air quality (IAQ) of a conditioned space. In this study, ceiling radiant cooling panel, mechanical ventilation with fan coil unit (FCU) and 100% fresh air are used. Temperature sensors are located at different locations inside the conditioned space in order to sense dry bulb temperatures, relative humidity to compare it with standard ASHRAE comfort values. The present investigation indicates that the radiant cooling system not only improves the indoor air quality but also reduces the building energy consumption in the conditioned space.

Mohamed, E.; Abdalla, K. N.

2010-01-01T23:59:59.000Z

292

Variable Speed Drive Volumetric Tracking (VSDVT) for Airflow Control in Variable Air Volume (VAV) Systems  

E-Print Network (OSTI)

An airflow control method has been developed for variable air volume (VAV) systems. This airflow control method is named VSD volumetric tracking (VSDVT) since both the supply and return airflows are determined using signals of the variable speed drives (VSD) instead of the flow stations. Its performance is studied and compared with the fan tracking (FT) method using model simulations. The VSDVT maintains a constant building pressure and the required outside airflow under all load conditions, reduces the annual return air fan energy by up to 50%, and the annual supply air fan energy by up to 30%. This paper presents the VSDVT method, the system models, and the simulation results.

Liu, M.

2002-01-01T23:59:59.000Z

293

Literature Review on Underfloor Air Distribution (UFAD) Systems  

E-Print Network (OSTI)

Various sources and search engines were used to find the technical research and literature by using specific keywords to search for the relevant reports or browsing through the list of documents. First, the 227 of references from the book “Underfloor Air Distribution (UFAD) Design Guide” by Fred S. Bauman were used to start searching literature. His references include papers, articles, and web references presenting major contributions to the understanding and development of UFAD technology and design. Other literature search methods were utilized. Below is the list of sources.

Im, P.; Cho, S.; Haberl, J. S.

2006-01-10T23:59:59.000Z

294

Theoretical Study of a Novel Control Method of VAV Air-conditioning System Based on MATLAB  

E-Print Network (OSTI)

The main purpose of this study is to put forward a novel nonlinear feedback control strategy on controlling indoor air temperature by variable air volume. A dynamic model of a typical room for a VAV air-conditioning system is established. The performance of the novel control strategy is investigated. Simulation of the controlling air temperature, on which the novel strategy is adopted, was carried out based on MATLAB in the VAV system. In order to show that the novel control strategy outperforms conventional PID control, a comparison is made between the performance of conventional PID and the novel nonlinear feedback control strategy. The results show that nonlinear feedback control strategy outperforms a conventional PID control system in terms of celerity, stability and other aspects.

Shi, Z.; Hu, S.; Wang, G.; Li, A.

2006-01-01T23:59:59.000Z

295

Experimental Evaluation of a Downsized Residential Air Distribution System: Comfort and Ventilation Effectiveness  

SciTech Connect

Good air mixing not only improves thermal comfort Human thermal comfort is the state of mind that expresses satisfaction with the surrounding environment, according to ASHRAE Standard 55. Achieving thermal comfort for most occupants of buildings or other enclosures is a goal of HVAC design engineers. but also enhances ventilation effectiveness by inducing uniform supply-air diffusion. In general, the performance of an air distribution system in terms of comfort and ventilation effectiveness is influenced by the supply air temperature, velocity, and flow rate, all of which are in part dictated by the HVAC (Heating Ventilation Air Conditioning) In the home or small office with a handful of computers, HVAC is more for human comfort than the machines. In large datacenters, a humidity-free room with a steady, cool temperature is essential for the trouble-free system as well as the thermal load attributes. Any potential deficiencies associated with these design variables can be further exacerbated by an improper proximity of the supply and return outlets with respect to the thermal and geometrical characteristics of the indoor space. For high-performance houses, the factors influencing air distribution performance take on an even greater significance because of a reduced supply-air design flow rate resulting from downsized HVAC systems.

Jalalzadeh-Azar, A. A.

2007-01-01T23:59:59.000Z

296

Quantitative evaluation of air-filtration systems in use at asbestos abatement sites: Research in progress  

Science Conference Proceedings (OSTI)

High Efficiency Particulate Air (HEPA) filtration systems serve as the principal engineering control to remove asbestos particulate from airstreams at abatement projects. However, little quantitative information is available on the integrity of these air-filtration systems in preventing asbestos fiber release into outdoor air or adjacent building areas, potentially exposing occupants. A study is in progress to assess the performance of HEPA filtration systems in use at asbestos abatement projects to determine each systems operating particle-removal efficiency, percent concentration, and decontamination factor. The asbestos-fiber concentration in the inlet and discharge air of each filtration system will be determined by isokinetic air sampling. Each isokinetic air sample collected will be analyzed using transmission electron microscopy. In addition, in-place aerosol performance testing will be conducted according to procedures outlined in ANSI/ASME N510-1980. The test method utilizes a polydispersed dioctyl phthalate aerosol (generated by Laskin nozzles) and a photometric light-scattering mass-concentration detector as the measuring device.

Powers, T.J.; Cain, W.C.; Wilmoth, R.C.; Kominsky, J.R.; Brownlee, J.A.

1989-01-01T23:59:59.000Z

297

Sensitivity of forced air distribution system efficiency to climate, duct location, air leakage and insulation  

Science Conference Proceedings (OSTI)

This study was performed in order to find suitable efficiency and leakage specifications for Energy Star duct systems and provide recommendations on duct insulation specifications. This analysis looks at a typical house, with a selection of duct locations, climates, duct insulation (R-value), and duct leakage. A set of calculations were performed with reduced capacity and airflow to look at the effect of variable capacity systems. This was done to address concerns regarding the increased efficiency of multi-capacity equipment due to good part load performance and how these efficiency gains may be offset by increased duct losses. The duct system efficiencies were calculated using the procedures in proposed ASHRAE Standard 152P ''Method of Test for Determining the Design and Seasonal Efficiencies of Residential Thermal Distribution Systems'' (ASHRAE 1999). This proposed ASHRAE Standard can be used to calculate duct efficiency for both design and seasonal weather conditions. In this report, the seasonal efficiencies are used for most of the analysis because they are the most appropriate for estimating energy consumption in buildings. The effects at peak conditions are examined for changing duct insulation in order to provide preliminary estimates of the potential responses to time of use pricing. The study was performed in two parts. The first part focused on duct leakage and the second part on duct insulation. The HVAC systems in the two parts share many attributes, however, they differ in detail and so are treated separately here. All the calculation results are summarized in tables in the Appendix, and specific results are given in the text.

Walker, Iain

2001-09-01T23:59:59.000Z

298

Solid handling valve  

DOE Patents (OSTI)

The present invention is directed to a solids handling valve for use in combination with lock hoppers utilized for conveying pulverized coal to a coal gasifier. The valve comprises a fluid-actuated flow control piston disposed within a housing and provided with a tapered primary seal having a recessed seat on the housing and a radially expandable fluid-actuated secondary seal. The valve seals are highly resistive to corrosion, erosion and abrasion by the solids, liquids, and gases associated with the gasification process so as to minimize valve failure.

Williams, William R. (Morgantown, WV)

1979-01-01T23:59:59.000Z

299

Air Conditioning with Magnetic Refrigeration : An Efficient, Green Compact Cooling System Using Magnetic Refrigeration  

SciTech Connect

BEETIT Project: Astronautics is developing an air conditioning system that relies on magnetic fields. Typical air conditioners use vapor compression to cool air. Vapor compression uses a liquid refrigerant to circulate within the air conditioner, absorb the heat, and pump the heat out into the external environment. Astronautics’ design uses a novel property of certain materials, called “magnetocaloric materials”, to achieve the same result as liquid refrigerants. These magnetocaloric materials essentially heat up when placed within a magnetic field and cool down when removed, effectively pumping heat out from a cooler to warmer environment. In addition, magnetic refrigeration uses no ozone-depleting gases and is safer to use than conventional air conditioners which are prone to leaks.

None

2010-09-01T23:59:59.000Z

300

Geothermal Systems are a Breath of Fresh Air for Illinois School District |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Geothermal Systems are a Breath of Fresh Air for Illinois School Geothermal Systems are a Breath of Fresh Air for Illinois School District Geothermal Systems are a Breath of Fresh Air for Illinois School District May 24, 2010 - 11:01am Addthis Each classroom has a geothermal unit installed. Although large, the units blend into surroundings and don’t produce excess noise. | Photo Courtesy of Sterling Public Schools Each classroom has a geothermal unit installed. Although large, the units blend into surroundings and don't produce excess noise. | Photo Courtesy of Sterling Public Schools Lindsay Gsell Superintendent Tad Everett had two priorities when deciding on a new system to replace the aging oil-based boiler heating and cooling systems for the seven schools in his district: improving learning environments and saving

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Geothermal Systems are a Breath of Fresh Air for Illinois School District |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Geothermal Systems are a Breath of Fresh Air for Illinois School Geothermal Systems are a Breath of Fresh Air for Illinois School District Geothermal Systems are a Breath of Fresh Air for Illinois School District May 24, 2010 - 11:01am Addthis Each classroom has a geothermal unit installed. Although large, the units blend into surroundings and don’t produce excess noise. | Photo Courtesy of Sterling Public Schools Each classroom has a geothermal unit installed. Although large, the units blend into surroundings and don't produce excess noise. | Photo Courtesy of Sterling Public Schools Lindsay Gsell Superintendent Tad Everett had two priorities when deciding on a new system to replace the aging oil-based boiler heating and cooling systems for the seven schools in his district: improving learning environments and saving

302

Sectional device handling tool  

DOE Patents (OSTI)

Apparatus for remotely handling a device in an irradiated underwater environment includes a plurality of tubular sections interconnected end-to-end to form a handling structure, the bottom section being adapted for connection to the device. A support section is connected to the top tubular section and is adapted to be suspended from an overhead crane. Each section is flanged at its opposite ends. Axially retractable bolts in each bottom flange are threadedly engageable with holes in the top flange of an adjacent section, each bolt being biased to its retracted position and retained in place on the bottom flange. Guide pins on each top flange cooperate with mating holes on adjacent bottom flanges to guide movement of the parts to the proper interconnection orientation. Each section carries two hydraulic line segments provided with quick-connect/disconnect fittings at their opposite ends for connection to the segments of adjacent tubular sections upon interconnection thereof to form control lines which are connectable to the device and to an associated control console.

Candee, Clark B. (Monroeville, PA)

1988-07-12T23:59:59.000Z

303

Improving the efficiency of residential air-distribution systems in California, Phase 1  

Science Conference Proceedings (OSTI)

This report describes the results of the first phase of a multiyear research project. The project`s goal is to investigate ways to improve the efficiency of air-distribution systems in detached, single-family residences in California. First-year efforts included: A survey of heating, ventilating, and air conditioning (HVAC) contractors in California. A 31-house field study of distribution-system performance based on diagnostic measurements. Development of an integrated air-flow and thermal-simulation tool for investigating residential air-distribution system performance. Highlights of the field results include the following: Building envelopes for houses built after 1979 appear to be approximately 30% tighter. Duct-system tightness showed no apparent improvement in post-1979 houses. Distribution-fan operation added an average of 0.45 air changes per hour (ACH) to the average measured rate of 0.24 ACH. The simulation tool developed is based on DOE-2 for the thermal simulations and on MOVECOMP, an air-flow network simulation model, for the duct/house leakage and flow interactions. The first complete set of simulations performed (for a ranch house in Sacramento) indicated that the overall heating-season efficiency of the duct systems was approximately 65% to 70% and that the overall cooling-season efficiency was between 60% and 75%. The wide range in cooling-season efficiency reflects the difference between systems with attic return ducts and those with crawl-space return ducts, the former being less efficient. The simulations also indicated that the building envelope`s UA-value, a measurement of thermoconductivity, did not have a significant impact on the overall efficiency of the air-distribution system.

Modera, M.; Dickerhoff, D.; Jansky, R.; Smith, B.

1992-06-01T23:59:59.000Z

304

Improving Control of a Dual-Duct Single-Fan Variable Air Volume Systems  

E-Print Network (OSTI)

This paper discusses improved control strategies for dual-duct single-fan variable air volume (VAV) systems. Common control strategy for supply air volume modulation is evaluated, and an improved air volume control strategy that maintains separate cold and hot air duct static pressure set points is presented. The paper also explores the interactions between the cold and hot deck temperatures and duct static pressures, and discusses the impact of non-ideal deck temperature settings on duct static pressures and overall system energy consumption. To compensate the negative impact of non-ideal cold and hot deck temperature set points, the authors propose using real-time duct static pressure readings as feedback signals to fine-tune the deck temperature set points. These new control schemes can reduce simultaneous cooling and heating while reducing fan power consumption.

Wei, G.; Martinez, J.; Minihan, T.; Brundidge, T.; Claridge, D. E.; Turner, W. D.

2003-01-01T23:59:59.000Z

305

Conceptual design of air-core superconducting power transformer for cable transmission system  

Science Conference Proceedings (OSTI)

The air-core superconducting transformer, which has a large magnetizing current, has been proposed as a power transformer that has the function as a shunt reactor. In this paper, the basic design procedure for the air-core superconducting transformer is presented. By using this procedure, 500/{radical}(3kV)--66/{radical}(3kV)--300 MVA single phase air-core transformer is designed for a model cable transmission system. Then, the performance of this transformer in the model cable transmission system is analyzed, and it is confirmed that the air-core superconducting transformer can function as a shunt reactor in addition to the principal as a power transformer.

Yamaguchi, Hiroshi; Sato, Yukihiko; Kataoka, Teruo [Tokyo Inst. of Tech. (Japan). Dept. of Electrical and Electronic Engineering

1996-04-01T23:59:59.000Z

306

Energy and Air Emission Implications of a Decentralized Wastewater System  

E-Print Network (OSTI)

water supply like desalination. The centralized facilitywater demand met through desalination would increase thewater is supplied through desalination. While septic systems

Shehabi, Arman

2013-01-01T23:59:59.000Z

307

Characterization of air recirculation in multiple fan ventilation systems.  

E-Print Network (OSTI)

??Booster fans, large underground fans, can increase the volumetric efficiency of ventilation systems by helping to balance the pressure and quantity distribution throughout a mine,… (more)

Wempen, Jessica Michelle

2012-01-01T23:59:59.000Z

308

Improving the Performance of Air-Conditioning Systems in an ASEAN Climate  

E-Print Network (OSTI)

This paper describes an analysis of air conditioning performance under hot and humid tropical climate conditions appropriate to the Association of South East Asian Nations (ASEAN) countries. This region, with over 280 million people, has one of the fastest economic and energy consumption growth rates in the world. The work reported here is aimed at estimating the conservation potential derived from good design and control of air conditioning systems in commercial buildings.

Busch, J. F.; Warren, M. L.

1988-01-01T23:59:59.000Z

309

The Impact of Forced Air System Blowers on Furnace Performance and Utility  

NLE Websites -- All DOE Office Websites (Extended Search)

The Impact of Forced Air System Blowers on Furnace Performance and Utility The Impact of Forced Air System Blowers on Furnace Performance and Utility Loads Speaker(s): Bert Phillips Date: November 7, 2003 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: James Lutz Bert Phillips will talk about the impact of forced air system blower performance on furnace or heating performance and on utility loads, and what can be done to reduce blower power requirements. He will also briefly discuss a ground source heat pump monitoring study that he just finished. Mr. Phillips is a registered Professional Engineer in three Canadian provinces and part owner of UNIES Ltd., an engineering firm in Winnipeg, Manitoba (60 miles straight north of the North Dakota/Minnesota border). He does research and HVAC system design and investigates

310

Effect of System and Air Contaminants on PEMFC Performance and Durability  

NLE Websites -- All DOE Office Websites (Extended Search)

Dinh Dinh (PI) National Renewable Energy Laboratory October 1, 2009 Effect of System and Air Contaminants on PEMFC Performance and Durability This presentation does not contain any proprietary, confidential, or otherwise restricted information Objectives To assist the DOE Fuel Cell Technologies (FCT) Program in meeting cost, durability, and performance targets in the areas of fuel cell systems. The effort is focused on system-derived contaminants, but has a small component addressing "gaps" in the area of air contaminants. Premise System-derived contaminants can have negative effect on fuel cell performance. Current density (A/cm 2 ) 0.0 0.2 0.4 0.6 0.8 1.0 1.2 g ( SHE ) Average cell voltage after air oxidation exposure Average cell voltage as measured in vehicle

311

Preliminary design package for residential heating/cooling system--Rankine air conditioner redesign  

DOE Green Energy (OSTI)

This report contains a summary of the preliminary redesign and development of a marketable single-family heating and cooling system. The objectives discussed are the interim design and schedule status of the Residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.

Not Available

1978-12-01T23:59:59.000Z

312

Energy Performance Comparison of Heating and Air Conditioning Systems for Multi-Family Residential Buildings  

SciTech Connect

The type of heating, ventilation and air conditioning (HVAC) system has a large impact on the heating and cooling energy consumption in multifamily residential buildings. This paper compares the energy performance of three HVAC systems: a direct expansion (DX) split system, a split air source heat pump (ASHP) system, and a closed-loop water source heat pump (WSHP) system with a boiler and an evaporative fluid cooler as the central heating and cooling source. All three systems use gas furnace for heating or heating backup. The comparison is made in a number of scenarios including different climate conditions, system operation schemes and applicable building codes. It is found that with the minimum code-compliant equipment efficiency, ASHP performs the best among all scenarios except in extremely code climates. WSHP tends to perform better than the split DX system in cold climates but worse in hot climates.

Wang, Weimin; Zhang, Jian; Jiang, Wei; Liu, Bing

2011-07-31T23:59:59.000Z

313

Issues and Factors of Train Air-conditioning System Design and Operation  

E-Print Network (OSTI)

Like a moving building, a train's outer meteorologic parameter will change a lot with the local meteorologic parameter on the way. In this paper, we put forward the design method of the typical design period and some dynamic energy-saving ways to solve the problem. These methods consider the dynamic changes of the outer environment when the train is moving, which will supply the theoretical basis for the calculation of the dynamic load and real-time running and regulation of the train's air-conditioning. Modifications to the air-conditioning system and some advanced air conditioning systems are introduced, which are helpful for system optimization. In this paper, based on analysis of the characteristics of the air - conditioning system in foreign high speed passenger cars and demands for its acceleration, developing trends for air - conditioning systems for high speed passenger cars are pointed out and some advice is put forward. Above all, we should not only satisfy the comfort need of the passengers, but also succeed in saving energy.

Liu, P.; Li, D.

2006-01-01T23:59:59.000Z

314

Thermal comfort and perceived air quality of a PEC system.  

E-Print Network (OSTI)

W. , Gong, N. 2007. Thermal performance of a personalizedRESULTS 1. Whole-body thermal sensation and comfort withthe PEC system Whole-body thermal sensation and comfort are

Arens, Edward; Zhang, Hui; Pasut, Wilmer

2011-01-01T23:59:59.000Z

315

Controlled air injection for a fuel cell system  

DOE Patents (OSTI)

A method and apparatus for injecting oxygen into a fuel cell reformate stream to reduce the level of carbon monoxide while preserving the level of hydrogen in a fuel cell system.

Fronk, Matthew H. (Honeove Falls, NY)

2002-01-01T23:59:59.000Z

316

Airborne Particulate Matter in HVAC Systems and its Influence on Indoor Air Quality  

E-Print Network (OSTI)

This paper first reviews the mechanisms governing movement of PMs in HVAC systems. Then, the basic equations governing PM deposition in ducts are introduced and investigations on airborne PMs distribution in HVAC systems are reviewed. The influence of PMs on indoor air quality and effectiveness of corresponding controlling measures is discussed extensively in the paper. Finally, recommendations for further research are given.

Fu, Z.; Li, N.; Wang, H.

2006-01-01T23:59:59.000Z

317

The Australian Air Quality Forecasting System. Part I: Project Description and Early Outcomes  

Science Conference Proceedings (OSTI)

The Australian Air Quality Forecasting System (AAQFS) is the culmination of a 3-yr project to develop a numerical primitive equation system for generating high-resolution (1–5 km) short-term (24–36 h) forecasts for the Australian coastal cities ...

M. E. Cope; G. D. Hess; S. Lee; K. Tory; M. Azzi; J. Carras; W. Lilley; P. C. Manins; P. Nelson; L. Ng; K. Puri; N. Wong; S. Walsh; M. Young

2004-05-01T23:59:59.000Z

318

Inertial-Dissipation Air-Sea Flux Measurements: A Prototype System Using Realtime Spectral Computations  

Science Conference Proceedings (OSTI)

A prototype system for the measurement and computation of air–sea fluxes in realtime was tested in the Humidity Exchange Over the Sea (HEXOS) main experiment, HEXMAX. The system used a sonic anemometer/thermometer for wind speed, surface stress ...

C. W. Fairall; J. B. Edson; S. E. Larsen; P. G. Mestayer

1990-06-01T23:59:59.000Z

319

Abstract: Air, Thermal and Water Management for PEM Fuel Cell Systems  

DOE Green Energy (OSTI)

PEM fuel cells are excellent candidates for transportation applications due to their high efficiencies. PEM fuel cell Balance of Plant (BOP) components, such as air, thermal, and water management sub-systems, can have a significant effect on the overall system performance, but have traditionally not been addressed in research and development efforts. Recognizing this, the U.S. Department of Energy and Honeywell International Inc. are funding an effort that emphasizes the integration and optimization of air, thermal and water management sub-systems. This effort is one of the major elements to assist the fuel cell system developers and original equipment manufacturers to achieve the goal of an affordable and efficient power system for transportation applications. Past work consisted of: (1) Analysis, design, and fabrication of a motor driven turbocompressor. (2) A systematic trade study to select the most promising water and thermal management systems from five different concepts (absorbent wheel humidifier, gas to gas membrane humidifier, porous metal foam humidifier, cathode recycle compressor, and water injection pump.) This presentation will discuss progress made in the research and development of air, water and thermal management sub-systems for PEM fuel cell systems in transportation applications. More specifically, the presentation will discuss: (1) Progress of the motor driven turbocompressor design and testing; (2) Progress of the humidification component selection and testing; and (3) Progress of the thermal management component preliminary design. The programs consist of: (1) The analysis, design, fabrication and testing of a compact motor driven turbocompressor operating on foil air bearings to provide contamination free compressed air to the fuel cell stack while recovering energy from the exhaust streams to improve system efficiency. (2) The analysis, design, fabrication and testing of selected water and thermal management systems and components to improve system efficiency and reduce packaging size.

Mark K. Gee

2008-10-01T23:59:59.000Z

320

Alternate Air Delivery Systems for Hot and Humid Climates  

E-Print Network (OSTI)

Carter & Burgess first began using triple deck multi-zone units, in place of traditional VAV systems, on the Texas State Capitol restoration. Since the completion of that project design in early 1991, our firm has now used triple deck multi-zone units in the Harris County Criminal Courts Building in Houston, one of the most hot and humid climates in the United States, as well as in several other facilities. This paper will discuss the adoption of ASHRAE 62, its effects on VAV systems, and how triple deck multi-zone units offer an alternative system to cooling in hot and humid climates. We recommend all design firms add triple deck multizone units to their repertoire of design solutions.

Wallace, M.

1996-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Total environmental warming impact (TEWI) calculations for alternative automative air-conditioning systems  

SciTech Connect

The Montreal Protocol phase-out of chlorofluorocarbons (CFCs) has required manufacturers to develop refrigeration and air-conditioning systems that use refrigerants that can not damage stratospheric ozone. Most refrigeration industries have adapted their designs to use hydrochlorofluorocarbon (HCFC) or hydrofluorocarbon (HFC) refrigerants; new automobile air- conditioning systems use HFC-134a. These industries are now being affected by scientific investigations of greenhouse warming and questions about the effects of refrigerants on global warming. Automobile air-conditioning has three separate impacts on global warming; (1) the effects of refrigerant inadvertently released to the atmosphere from accidents, servicing, and leakage; (2) the efficiency of the cooling equipment (due to the emission of C0{sub 2} from burning fuel to power the system); and (3) the emission of C0{sub 2} from burning fuel to transport the system. The Total Equivalent Warming Impact (TEWI) is an index that should be used to compare the global warming effects of alternative air-conditioning systems because it includes these contributions from the refrigerant, cooling efficiency, and weight. This paper compares the TEWI of current air-conditioning systems using HFC-134a with that of transcritical vapor compression system using carbon dioxide and systems using flammable refrigerants with secondary heat transfer loops. Results are found to depend on both climate and projected efficiency of C0{sub 2}systems. Performance data on manufacturing prototype systems are needed to verify the potential reductions in TEWI. Extensive field testing is also required to determine the performance, reliability, and ``serviceability`` of each alternative to HFC-134a to establish whether the potential reduction of TEWI can be achieved in a viable consumer product.

Sand, J.R.; Fischer, S.K.

1997-01-01T23:59:59.000Z

322

On the Contribution of Compressed Air Systems to Energy Efficiency Targets  

NLE Websites -- All DOE Office Websites (Extended Search)

On the Contribution of Compressed Air Systems to Energy Efficiency Targets On the Contribution of Compressed Air Systems to Energy Efficiency Targets - A Function-Based Bottom-Up Approach Speaker(s): Patrick Plötz Date: May 4, 2012 - 2:00pm Location: 90-4133 Seminar Host/Point of Contact: Sanaee Iyama Achieving current EU energy targets as stipulated in the energy service directive and in the energy strategy for 2020 implies substantial efficiency improvements across a variety of industrial end-uses. The achievable saving potential of an end-use depends considerably on the age structure of the existing stock and on the technology definition, i.e. whether a product approach, an extended product approach or a system-approach is used. Within this context, important ErP studies on air compressors are in preparation. In this paper, we address the possible

323

A triple hot-wire system for indoor air flow measurements  

SciTech Connect

The application of a home made, triple hot-wire system in indoor air flow measurements is presented. Both the anemometer and sensor have been developed at Athens University with the aim to provide a reliable, research tool of reasonable cost, simple construction, and satisfactory performance. All three velocity components above a threshold of 10 cm s{sup {minus}1} can be measured. The system is also equipped with two thermometers for measuring the mean and fluctuating air temperature and for providing a means of temperature compensation of the hot wires` signal. After evaluation of the system in the laboratory, it was used in the measurement of the velocity profile of flows driven by the temperature difference between two internal zones. The implied accuracy of the method allows for its integration with measurements of air volume exchange rates between internal zones, as estimated by tracer gas techniques.

Papadopoulos, K.H.; Soilemes, A.T.; Helmis, C.G.; Santamouris, M.; Dascalaki, E. [Univ. of Athens (Greece); Asimakopoulos, D.N. [Univ. of Athens (Greece)]|[National Observatory of Athens (Greece). Inst. of Meteorology and Physics of the Atmospheric Environment; Argiriou, A. [National Observatory of Athens (Greece). Inst. of Meteorology and Physics of the Atmospheric Environment

1996-08-01T23:59:59.000Z

324

Method and apparatus for operating a self-starting air heating system  

DOE Patents (OSTI)

A self-starting, fuel fired, air heating system including a fuel burner fired vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser and heating the air. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with a method and apparatus which on start-up prevents the vapor generator's vapor output from being conducted to the turbine until a predetermined pressure differential has been achieved. However, after the vapor flow is once permitted, it cannot again be prevented until after the fuel burner has been shut off and restarted.

Heinrich, Charles E. (Mentor, OH)

1983-12-06T23:59:59.000Z

325

An Air-Launched Atmospheric Sounding System (ALMET)  

Science Conference Proceedings (OSTI)

This article describes a system to provide standard atmospheric soundings in remote oceanic regions. Deployed from an aircraft, the expendable unit descends to within 15 m of the ocean surface on a parachute and then releases a 500-g balloon and ...

Michael A. Bellmore; D. Ray Booker; Ken Winter

1994-02-01T23:59:59.000Z

326

THE IMPACT OF AIR POLLUTION CONTROL SYSTEM DESIGN ON  

E-Print Network (OSTI)

). Therefore, without cooling the flue gas, significant quantities of mercury will pass through the particulate, page 4824. Licata, A., et al, June 1994, "An Economic Alternative to Controlling Acid Gases, Mercury electrostatic precipitator combination. -Selective Non-Catalytic Reduction System to reduce nitrogen oxide

Columbia University

327

Simulations of sizing and comfort improvements for residential forced-air heating and cooling systems  

SciTech Connect

In many parts of North America residential HVAC systems are installed outside conditioned space. This leads to significant energy losses and poor occupant comfort due to conduction and air leakage losses from the air distribution ducts. In addition, cooling equipment performance is sensitive to air flow and refrigerant charge that have been found to be far from manufacturers specifications in most systems. The simulation techniques discussed in this report were developed in an effort to provide guidance on the savings potentials and comfort gains that can be achieved by improving ducts (sealing air leaks) and equipment (correct air-flow and refrigerant charge). The simulations include the complex air flow and thermal interactions between duct systems, their surroundings and the conditioned space. They also include cooling equipment response to air flow and refrigerant charge effects. Another key aspect of the simulations is that they are dynamic to account for cyclic losses from the HVAC system and the effect of cycle length on energy and comfort performance. To field test the effect of changes to residential HVAC systems requires extensive measurements to be made for several months for each condition tested. This level of testing is often impractical due to cost and time limitations. Therefore the Energy Performance of Buildings Group at LBNL developed a computer simulation tool that models residential HVAC system performance. This simulation tool has been used to answer questions about equipment downsizing, duct improvements, control strategies and climate variation so that recommendations can be made for changes in residential construction and HVAC installation techniques that would save energy, reduce peak demand and result in more comfortable homes. Although this study focuses on California climates, the simulation tool could easily be applied to other climates. This report summarizes the simulation tool and discusses the significant developments that allow the use of this tool to perform detailed residential HVAC system simulations. The simulations have been verified by comparison to measured results in several houses over a wide range of weather conditions and HVAC system performance. After the verification was completed, more than 350 cooling and 450 heating simulations were performed. These simulations covered a range of HVAC system performance parameters and California climate conditions (that range from hot dry deserts to cold mountain regions). The results of the simulations were used to show the large increases in HVAC system performance that can be attained by improving the HVAC duct distribution systems and by better sizing of residential HVAC equipment. The simulations demonstrated that improved systems can deliver improved heating or cooling to the conditioned space, maintain equal or better comfort while reducing peak demand and the installed equipment capacity (and therefore capital costs).

Walker, I.S.; Degenetais, G.; Siegel, J.A.

2002-05-01T23:59:59.000Z

328

The Technical and Economical Analysis of the Air-conditioning System Usage in Residential Buildings in Beijing  

E-Print Network (OSTI)

In this paper, we show that the air-conditioning usage in residential buildings in Beijing grows rapidly in relation to the development of civil construction. More and more people are not satisfied with the current style of only using split air-conditioning units in residential buildings, and are using the central air-conditioning system in residential buildings. To determine the best air conditioning mode, a residential tower building with 22 layers was chosen for analysis. The advantages and disadvantages of the central air-conditioning system and the residential multi-unit air-conditioning equipment system and the LiBr absorption chiller were compared based on calculating the first-cost and the annual cost (according to providing cooling 90 days annually). The predicted results show the economical feasibility of using the refrigerating units in air-conditioning systems in Beijing region, and point out the developing directions for the future.

Sheng, G.; Xie, G.

2006-01-01T23:59:59.000Z

329

Research on Automatically Identification of Diagonal Air-flow Branches of Complex Ventilation System of Coal Mines  

Science Conference Proceedings (OSTI)

air-flow branches identification and stability analysis is one of the core contents of stability and reliability theory of mine ventilation system. This current paper takes deeply research on diagonal air-flow branches. Limitations of the path method ... Keywords: diagonal air-flow branch, path collection, path method, node-position method

Feng Cai, Zegong Liu

2012-07-01T23:59:59.000Z

330

A comparative assessment of alternative combustion turbine inlet air cooling system  

SciTech Connect

Interest in combustion turbine inlet air cooling (CTAC) has increased during the last few years as electric utilities face increasing demand for peak power. Inlet air cooling increases the generating capacity and decreases the heat rate of a combustion turbine during hot weather when the demand for electricity is generally the greatest. Several CTAC systems have been installed, but the general applicability of the concept and the preference for specific concepts is still being debated. Concurrently, Rocky Research of Boulder City, Nevada has been funded by the U.S. Department of Energy to conduct research on complex compound (ammoniated salt) chiller systems for low-temperature refrigeration applications.

Brown, D.R.; Katipamula, S.; Konynenbelt, J.H.

1996-02-01T23:59:59.000Z

331

Indoor Air Nuclear, Biological, and Chemical Health Modeling and Assessment System  

SciTech Connect

Indoor air quality effects on human health are of increasing concern to public health agencies and building owners. The prevention and treatment of 'sick building' syndrome and the spread of air-borne diseases in hospitals, for example, are well known priorities. However, increasing attention is being directed to the vulnerability of our public buildings/places, public security and national defense facilities to terrorist attack or the accidental release of air-borne biological pathogens, harmful chemicals, or radioactive contaminants. The Indoor Air Nuclear, Biological, and Chemical Health Modeling and Assessment System (IA-NBC-HMAS) was developed to serve as a health impact analysis tool for use in addressing these concerns. The overall goal was to develop a user-friendly fully functional prototype Health Modeling and Assessment system, which will operate under the PNNL FRAMES system for ease of use and to maximize its integration with other modeling and assessment capabilities accessible within the FRAMES system (e.g., ambient air fate and transport models, water borne fate and transport models, Physiologically Based Pharmacokinetic models, etc.). The prototype IA-NBC-HMAS is designed to serve as a functional Health Modeling and Assessment system that can be easily tailored to meet specific building analysis needs of a customer. The prototype system was developed and tested using an actual building (i.e., the Churchville Building located at the Aberdeen Proving Ground) and release scenario (i.e., the release and measurement of tracer materials within the building) to ensure realism and practicality in the design and development of the prototype system. A user-friendly "demo" accompanies this report to allow the reader the opportunity for a "hands on" review of the prototype system's capability.

Stenner, Robert D.; Hadley, Donald L.; Armstrong, Peter R.; Buck, John W.; Hoopes, Bonnie L.; Janus, Michael C.

2001-03-01T23:59:59.000Z

332

Indoor Air Nuclear, Biological, and Chemical Health Modeling and Assessment System  

SciTech Connect

Indoor air quality effects on human health are of increasing concern to public health agencies and building owners. The prevention and treatment of 'sick building' syndrome and the spread of air-borne diseases in hospitals, for example, are well known priorities. However, increasing attention is being directed to the vulnerability of our public buildings/places, public security and national defense facilities to terrorist attack or the accidental release of air-borne biological pathogens, harmful chemicals, or radioactive contaminants. The Indoor Air Nuclear, Biological, and Chemical Health Modeling and Assessment System (IA-NBC-HMAS) was developed to serve as a health impact analysis tool for use in addressing these concerns. The overall goal was to develop a user-friendly fully functional prototype Health Modeling and Assessment system, which will operate under the PNNL FRAMES system for ease of use and to maximize its integration with other modeling and assessment capabilities accessible within the FRAMES system (e.g., ambient air fate and transport models, water borne fate and transport models, Physiologically Based Pharmacokinetic models, etc.). The prototype IA-NBC-HMAS is designed to serve as a functional Health Modeling and Assessment system that can be easily tailored to meet specific building analysis needs of a customer. The prototype system was developed and tested using an actual building (i.e., the Churchville Building located at the Aberdeen Proving Ground) and release scenario (i.e., the release and measurement of tracer materials within the building) to ensure realism and practicality in the design and development of the prototype system. A user-friendly "demo" accompanies this report to allow the reader the opportunity for a "hands on" review of the prototype system's capability.

Stenner, Robert D.; Hadley, Donald L.; Armstrong, Peter R.; Buck, John W.; Hoopes, Bonnie L.; Janus, Michael C.

2001-03-01T23:59:59.000Z

333

Performance Assessment of a Variable Refrigerant Flow Heat Pump Air Conditioning System  

Science Conference Proceedings (OSTI)

Variable refrigerant flow (VRF) technology uses smart integrated controls, variable speed drives, and refrigerant piping to provide energy efficiency, flexible operation, ease of installation, low noise, zone control, and comfort through all-electric technology. This report describes and documents the construction, performance, and application of a heat pump air conditioning system that uses VRF technology8212the Daikin VRV system. This variable refrigerant volume (VRV) system is manufactured by Daikin I...

2008-12-17T23:59:59.000Z

334

REMOTE HANDLING ARRANGEMENTS  

DOE Patents (OSTI)

A means for handling remotely a sample pellet to be irradiated in a nuclear reactor is proposed. It is comprised essentially of an inlet tube extending through the outer shield of the reactor and being inclined so that its outer end is at a higher elevation than its inner end, an outlet tube extending through the outer shield being inclined so that its inner end is at a higher elevation than its outer end, the inner ends of these two tubes being interconnected, and a straight tube extending through the outer shield and into the reactor core between the inlet and outlet tubes and passing through the juncture of said inner ends. A rod-like member is rotatably and slidely operated within the central straight tube and has a receptacle on its inner end for receiving a sample pellet from the inlet tube. The rod member is operated to pick up a sample pellet from the inlet tube, carry the sample pellet into the irradiating position within the core, and return to the receiving position where it is rotated to dump the irradiated pellet into the outlet tube by which it is conveyed by gravity to the outside of the reactor. Stop members are provided in the inlet tube, and electrical operating devices are provided to control the sequence of the operation automatically.

Ginns, D.W.

1958-04-01T23:59:59.000Z

335

ALTERNATE HIGH EFFICIENCY PARTICULATE AIR (HEPA) FILTRATION SYSTEM  

SciTech Connect

In Phase IIA of this project, CeraMem has further developed and scaled up ceramic HEPA filters that are appropriate for use on filtration of vent gas from HLW tanks at DOE sites around the country. This work included procuring recrystallized SiC monoliths, developing membrane and cement materials, and defining a manufacturing process for the production of prototype full sizes HEPA filters. CeraMem has demonstrated that prototype full size filters can be manufactured by producing 9 full size filters that passed DOP aerosol testing at the Oak Ridge Filter Test Facility. One of these filters was supplied to the Savannah River Technical Center (SRTC) for process tests using simulated HLW tank waste. SRTC has reported that the filter was regenerable (with some increase in pressure drop) and that the filter retained its HEPA retention capability. CeraMem has also developed a Regenerable HEPA Filter System (RHFS) design and acceptance test plan that was reviewed by DOE personnel. The design and acceptance test plan form the basis of the system proposal for follow-on work in Phase IIB of this project.

Bruce Bishop; Robert Goldsmith; Karsten Nielsen; Phillip Paquette

2002-08-16T23:59:59.000Z

336

Application of the VRV Air-Conditioning System Heat Recovery Series in Interior Zone and Analysis of its Energy Saving  

E-Print Network (OSTI)

To reduce the energy consumption of air conditioning systems, we can use the VRV air conditioning system to supply cold loads in the winter for rooms in the construction inner zone where cold loads need to be supplied. The VRV air-conditioning system of variable frequency technology can achieve the effect of energy conservation. In this article, we analyze the application of the VRV air conditioning system heat recovery series in the construction inner zone and its energy saving characteristics via a project example.

Zhang, Q.; Li, D.; Zhang, J.

2006-01-01T23:59:59.000Z

337

Improve Compressed Air System Performance with AIRMaster+, Software Tools for Industry, Industrial Technologies Program (ITP) (Fact Sheet)  

SciTech Connect

This fact sheet describes how the Industrial Technologies Program AIRMaster+ software tool can help industrial plants optimize compressed air system efficiency.

2008-12-01T23:59:59.000Z

338

Development of standardized air-blown coal gasifier/gas turbine concepts for future electric power systems  

Science Conference Proceedings (OSTI)

The objective of this study is to develop standardized air blown fixed bed gasification hot gas cleanup integrated gasifier combined cycle (IGCC) systems.

Sadowski, R.S.; Brown, M.J.; Hester, J.C.; Harriz, J.T.; Ritz, G.J.

1991-02-01T23:59:59.000Z

339

Management processes in U.S. air traffic management modernization : a study of global navigation satellite system development  

E-Print Network (OSTI)

This thesis investigates organization and management issues associated with the Federal Aviation Administration's (FAA) efforts to modernize the nation's Air Traffic Management (ATM) system. Focus is placed specifically ...

Sandvig, John H.

1994-01-01T23:59:59.000Z

340

History of remote handling at LAMPF  

SciTech Connect

A portable remote-handling system (Monitor) has been developed for performing remote maintenance on radioactive experimental facilities at the Clinton P. Anderson Meson Physics Facility (LAMPF). This system has been continually improved since its implementation in 1976. The present system has performed highly sophisticated tasks in improving and maintaining the LAMPF experimental facility. Unlike conventional hot-cell remote-handling technology, the Monitor system is portable and highly flexible, thereby allowing quick response to unforeseen tasks with minimal planning and/or special tooling. In addition to performing routine maintenance and repairs, the Monitor system is capable of performing major revisions and improvements to current facilities, keeping pace with new experimental requirements.

Grisham, D.L.; Lambert, J.E.

1982-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Validation of the RVACS (Reactor Vessel Auxiliary Cooling System)/RACS (Reactor Air Cooling System) model in SASSYS-1  

SciTech Connect

The SASSYS-1 LMR systems analysis code contains a model for transient analysis of heat removal by a RVACS (Reactor Vessel Auxiliary Cooling System) or a RACS (Reactor Air Cooling System) in an LMR (Liquid Metal Reactor). This model has been validated by comparisons of model predictions with experimental data from a large scale RVACS/RACS simulation experiment performed at Argonne National Laboratory. 4 refs., 1 fig.

Dunn, F.E.

1987-01-01T23:59:59.000Z

342

Dual Path HVAC System Demonstration in School: Leveraging Thermal Energy Storage and Cold Air Distribution to Enhance System Perform ance in a Florida Elementary School  

Science Conference Proceedings (OSTI)

This document reports on a novel dual-path, low-temperature air distribution system demonstrated in a Florida elementary school. This system addresses high humidity levels and indoor air quality problems normally found in schools due to their large ventilation requirements, especially in humid climates. The dual-path system is also integrated with synergistic use of thermal energy storage and low-temperature air distribution, reduced energy use, and initial cost. The field data confirmed that the system ...

2002-10-21T23:59:59.000Z

343

Analysis System for Measurement of CO2 Mixing Ratios in Flask Air Samples  

Science Conference Proceedings (OSTI)

A system for measuring the concentration of CO2 in flask air samples from the NOAA/CMDL worldwide flask sampling network is described. Up to 180 samples per day can he analyzed using a nondispersive infrared CO2 analyzer. All data acquisition and ...

Kirk W. Thoning; Thomas J. Conway; Ni Zhang; Duane Kitzis

1995-12-01T23:59:59.000Z

344

Environmental turbulent mixing controls on air-water gas exchange in marine and aquatic systems  

E-Print Network (OSTI)

climatically important trace gas fluxes on regional and global scales, yet the magnitude of the transfer-generated turbulence in a shallow tidal sea, Nature, 400, 251­254. Raymond, P. A., and J. J. Cole (2001), Gas exchangeEnvironmental turbulent mixing controls on air-water gas exchange in marine and aquatic systems

Ho, David

345

Dynamical Aspects of Wintertime Cold-Air Pools in an Alpine Valley System  

Science Conference Proceedings (OSTI)

This study presents high-resolution numerical simulations in order to examine the dynamical mechanisms controlling the persistence of wintertime cold-air pools in an Alpine valley system. First, a case study of a cold-pool episode is conducted, ...

Günther Zängl

2005-09-01T23:59:59.000Z

346

Integrative path planning and motion control for handling large components  

Science Conference Proceedings (OSTI)

For handling large components a large workspace and high precision are required. In order to simplify the path planning for automated handling systems, this task can be divided into global, regional and local motions. Accordingly, different types of ... Keywords: integrative production, motion control, path planning, robotic assembly application

Rainer Müller; Martin Esser; Markus Janssen

2011-12-01T23:59:59.000Z

347

Biodiesel Handling and Use Guide | Open Energy Information  

Open Energy Info (EERE)

Biodiesel Handling and Use Guide Biodiesel Handling and Use Guide Jump to: navigation, search Tool Summary Name: Biodiesel Handling and Use Guide Agency/Company /Organization: National Renewable Energy Laboratory Focus Area: Fuels & Efficiency Topics: Best Practices Website: www.nrel.gov/vehiclesandfuels/npbf/pdfs/43672.pdf This document is a guide for those who blend, store, distribute, and use biodiesel. It is intended to help fleets, individual users, blenders, distributors, and those involved in related activities understand procedures for handling and using biodiesel fuels. How to Use This Tool This tool is most helpful when using these strategies: Avoid - Cut the need for travel Shift - Change to low-carbon modes Improve - Enhance infrastructure & policies Learn more about the avoid, shift, improve framework for limiting air

348

In-Plant Ash-Handling Reference Manual  

Science Conference Proceedings (OSTI)

Despite problems with ash-handling systems that have led to failures in electrostatic precipitators, there has been no extensive reference manual for specifying, operating, and maintaining such systems. The comprehensive manual compiled in this study serves as a reference for every phase of boiler bottom ash- and fly ash-handling systems design and operation as well as a primer for those unfamiliar with these systems.

1986-12-01T23:59:59.000Z

349

THE DEVELOPMENT OF PROTECTIVE EQUIPMENT FOR NUCLEAR DECONTAMINATION SYSTEMS  

SciTech Connect

BS>A review of various types of protective equipment used in connection with radioactive decontamination systems is presented. A description of decontamination areas, decontamination methods, laundry techniques, active waste handling, protective suits, air hose systems, control room systems, clean air supplies, routine maintenance and emergency systems, mobile units, disposable suit techniques, respirators and air line masks, and high velocity cooling systems is given. (C.E.S.)

Thorne, A.C.

1963-06-01T23:59:59.000Z

350

The use of air as a natural tracer infractured hydrothermal systems, Los Azufres, Mexico, case study  

DOE Green Energy (OSTI)

Injection of atmospheric air mixed with cold water has been occurring since 1982 at the Los Azufres geothermal field. Several chemical and thermodynamical evidences show that air injection into this fractured hydrothermal system could be considered as a long term natural tracer test. Nitrogen and Argon separated from the air mixture migrate, under the action of the induced injection-extraction gradient, from reinjection sectors to production zones following preferential paths closely related to high permeability conduits. A coarse numerical estimation of the average permeability tensor existing at Tejamaniles, the southern sector, explains the unsuccessful recovery of the artificial tracer tests performed in past years: the anisotropic nature of the fractured volcanic rock would demand considerably quantities of tracer in order to be detected at the producing wells, especially when fluid extraction was low. At the same time concentrations of calcium, cesium, chloride, potassium, rubidium and sodium, are increasing in the liquid produced by the oldest wells of this field's sector.

Mario Cesar Sudrez Arriaga; Hector Gutierrez Puente, Josefina Moreno Ochoa

1991-01-01T23:59:59.000Z

351

New fault locating system for air-insulated substations using optical current detector  

Science Conference Proceedings (OSTI)

This paper deals with a newly developed fault locating system. This fault locating system helps to shorten the time required for restoration of service after the occurrence of a busbar fault in an air-insulated distribution substation. Recent optical and electronic technologies allow highly accurate and compact fault locating system, which consists of optical current detectors using Faraday effect and a fault locating processor employing digital data processing technique. The fault location is made by discriminating the direction of zero-sequence currents. Through various tests and field operations it has been confirmed that the system has sufficient performance for practical application.

Yoshida, Y.; Kawazoe, S. (Kansai Electric Power Co., Inc., Osaka (Japan)); Ibuki, K.; Yamada, K.; Ochi, N. (Mitsubishi Electric Corp., Amagasaki, Hyogo (Japan). Itami Works)

1992-10-01T23:59:59.000Z

352

Start-Up of Air Conditioning Systems After Periods of Shutdown (Humidity Considerations)  

E-Print Network (OSTI)

In many cases the single most important energy conservation measure that can be taken is to turn equipment off when it is not needed. In the case of air conditioning, this generally means turning it off when occupants leave and turning it back on in time to have the space comfortable when they return. In humid climates special problems are often encountered when a system is restarted after a period of shutdown. The temperature and humidity in the space rises during the period of shutdown. Unfortunately the latent load required to bring the space back to comfort conditions is usually much higher than the sensible load. Most methods of control are ill suited for this duty. This paper examines the response of various types of air conditioning systems during this recovery period and makes recommendations for system designers.

Todd, T. R.

1986-01-01T23:59:59.000Z

353

The Experimentation System Design and Experimental Study of the Air-Conditioning by Desiccant Type Using Solar Energy  

E-Print Network (OSTI)

Using a special solar air heater to gain heat power for regenerating an adsorption desiccant wheel made by composite silica gel, a desiccant air-conditioning experimentation system was designed and manufactured. Combining the advantage of measure and control by “PLC” and the software of “Kingview”, the whole year's operating results of this system was tested and analysed. The results indicate this system can keep the indoor air temperature range at 26±2°C and the relative humidity range being 50-70% under the low electricity cost on the whole year in the south of China region when the special solar air heater can offer flux air heating up to 60°C. In this paper some ideas are offered in order to facilitate the availability for air-conditioning using low grade energy, for example, solar energy and surplus or waste heat energy in the industrial process.

Zhuo, X.; Ding, J.; Yang, X.; Chen, S.; Yang, J.

2006-01-01T23:59:59.000Z

354

Assuring safety through operational approval : challenges in assessing and approving the safety of systems-level changes in air transportation  

E-Print Network (OSTI)

To improve capacity and efficiency of the air transportation system, a number of new systems-level changes have been proposed. Key aspects of the proposed changes are combined functionality across technology and procedures ...

Weibel, Roland E. (Roland Everett)

2010-01-01T23:59:59.000Z

355

Modeling of an adiabatic packed bed brine-air contactor for use in a solar energy driven food processing system  

Science Conference Proceedings (OSTI)

A mathematical model was developed for a packed bed brine-air contacting system which has applications in a solar energy driven food processing system. The model considers mass transfer resistances of both phases, but neglects the heat transfer resistance of the liquid phase. It takes into account the large heat effects associated with water absorption into and desorption from the brine. A computational method was also developed to calculate the minimum air flow rate which would prevent a pinch. A packed bed brine-air contactor was built, and experiments were conducted for a range of brine and air conditions. Good agreement between the computed and experimental results warrants use of the model to design and optimize the packed bed water stripping process. A periodic-flow packed bed heat regenerator was built to recover heat from the exit air of the contactor so as to improve the energy efficiency of the system. It was possible to preheat the inlet air to a temperature close to that of the exit air. The inlet air, however, during its passage through the regenerator picked up the condensate deposited from the exit air. This led to a decrease in the driving potential to mass transfer in the contactor. Optimization studies show that using a combined solar driven boiler and air assisted packed bed water stripper would be more economical than using a solar driven boiler alone or using flat plate solar collectors to drive the water stripper.

Biswal, R.N.

1983-01-01T23:59:59.000Z

356

Biodiesel Handling and Use Guidelines  

DOE Green Energy (OSTI)

This document is a field guide for end-users, distributors, and those involved in related activities. These guidelines cover fuel use and handling issues that could be anticipated or encountered in the field.

Tyson, S.

2001-09-05T23:59:59.000Z

357

Module Development and Simulation of the Variable Refrigerant Flow Air Conditioning System under Cooling Conditions in Energyplus  

E-Print Network (OSTI)

As a high-efficiency air conditioning scheme, the variable refrigerant flow (VRF) air-conditioning system is finding its way into medium-sized office buildings. Based on a generic dynamic building energy simulation environment, EnergyPlus, a new module is developed and the energy usage of the VRF system is investigated. This paper compares the energy consumption of the VRF system with that of two conventional air-conditioning systems, namely, the variable air volume (VAV) system and the fan-coil plus fresh air (FPFA) system. A generic office building is used to accommodate the different types of heating, ventilating, and air conditioning (HVAC) systems. Our objective is to examine the energy consumption of the VRF system applied to office buildings and make suggestions for evaluating and making decisions on HVAC systems in the early stages of building design. Simulation results show that the energy-saving potential of the VRF system is expected to achieve 22.2 percent and 11.7 percent, compared to the VAV system and the FPFA system, respectively. An energy-usage breakdown of electricity end-users in various systems is also presented.

Zhou, Y.; Wu, J.; Wang, R.; Shiochi, S.

2006-01-01T23:59:59.000Z

358

AQUIS: A PC-based air quality and permit information system  

SciTech Connect

The Air Quality Utility Information System (AQUIS) was developed to calculate and track emissions, permits, and related information. The system runs on IBM-compatible personal computers using dBASE IV. AQUIS tracks more than 900 data items distributed among various source categories and allows the user to enter specific information on permit control devices, stacks, and related regulatory requirements. The system is currently operating at seven US Air Force Materiel Command facilities, large industrial operations involved in the repair and maintenance of aircraft. Environmental management personnel are responsible for the compliance status of as many as l,000 sources at each facility. The usefulness of the system has been enhanced by providing a flexible reporting capability that permits users who are unfamiliar with database structure to design and prepare reports containing specified information. In addition to the standard six pollutants, AQUIS calculates compound-specific emissions and allows users to enter their own emission estimates. This capability will be useful in developing air toxics inventories and control plans.

Smith, A.E.; Huber, C.C.; Tschanz, J. [Argonne National Lab., IL (United States); Ryckman, J.S. Jr. [Air Force Air Materiel Command, Wright-Patterson AFB, OH (United States)

1992-09-01T23:59:59.000Z

359

FY 1977 Progress report, Compressed air energy storage advanced systems analysis.  

DOE Green Energy (OSTI)

The goal of the Compressed Air Energy Storage (CAES) Advanced Systems Analysis task is to accelerate the development of new technologies that will reduce the consumption of natural gas and oil. The immediate overall objectives of this program are to: (1) provide a screening cost assessment for thermal energy storage (TES) systems that are suitable for CAES applications; (2) establish the potential fuel savings of hybrid CAES cycles that incorporate TES for recovery of the heat of compression and estimate the economic incentive for using TES in CAES systems; and (3) investigate modified CAES cycles that eliminate the use of gas and oil by the use of alternative fuels.

Kreid, D.K.; McKinnon, M.A.

1978-03-01T23:59:59.000Z

360

Direct-contact air/molten salt heat exchange for solar-thermal systems  

DOE Green Energy (OSTI)

Heat exchangers employing direct contact between molten draw salt and air were studied for use in solar industrial process heat (IPH) systems. Direct-contact systems consisting of a fin-tube preheater and a spray or packed column were compared to conventional heat exchangers. Direct contact reduced the IPH system cost by 5% to 10%. The direct-contact heat exchangers cost only 15% to 30% as much as comparable conventional exchangers. However, the rate of salt degradation by CO/sup 2/ and H/sub 2/O must be determined to see if it is acceptable.

Wright, J.D.; d'Agincourt, C.

1982-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

LiCl Dehumidifier LiBr absorption chiller hybrid air conditioning system with energy recovery  

SciTech Connect

This invention relates to a hybrid air conditioning system that combines a solar powered LiCl dehumidifier with a LiBr absorption chiller. The desiccant dehumidifier removes the latent load by absorbing moisture from the air, and the sensible load is removed by the absorption chiller. The desiccant dehumidifier is coupled to a regenerator and the desiccant in the regenerator is heated by solar heated hot water to drive the moisture therefrom before being fed back to the dehumidifier. The heat of vaporization expended in the desiccant regenerator is recovered and used to partially preheat the driving fluid of the absorption chiller, thus substantially improving the overall COP of the hybrid system.

Ko, Suk M. (Huntsville, AL)

1980-01-01T23:59:59.000Z

362

Aiding Air Force budget analysis with expert system tools and techniques  

SciTech Connect

A system to capture US Air Force financial expertise is currently under development. To accomplish its mission of costing Air Force programs, the Director of the Budget utilizes the services of budget analysts. Analysts are required to prepare three cost exercises during the year: the Program Objective Memorandum (POM), the Budget Estimation Submission (BES), and the President's Budget (PB). Additionally, during budget calls and budget execution, analysts must make decisions regarding funding obligations and outlays. Analysis and modification of outlay projection plans require the use of operational and procedural heuristics. These problem-solving steps followed by analysts are being used to develop a prototype. Information regarding the prototype, the tool, and its capabilities are presented. Additional features of the program are described including integration with existing information management systems.

Hardee, H.K.; Jones, K.A.; Morris, J.D.; Emrich, M.L.; Ali, H.

1987-09-14T23:59:59.000Z

363

Cascade Reverse Osmosis Air Conditioning System: Cascade Reverse Osmosis and the Absorption Osmosis Cycle  

SciTech Connect

BEETIT Project: Battelle is developing a new air conditioning system that uses a cascade reverse osmosis (RO)-based absorption cycle. Analyses show that this new cycle can be as much as 60% more efficient than vapor compression, which is used in 90% of air conditioners. Traditional vapor-compression systems use polluting liquids for a cooling effect. Absorption cycles use benign refrigerants such as water, which is absorbed in a salt solution and pumped as liquid—replacing compression of vapor. The refrigerant is subsequently separated from absorbing salt using heat for re-use in the cooling cycle. Battelle is replacing thermal separation of refrigerant with a more efficient reverse osmosis process. Research has shown that the cycle is possible, but further investment will be needed to reduce the number of cascade reverse osmosis stages and therefore cost.

None

2010-09-01T23:59:59.000Z

364

Boiler Upgrades and Decentralizing Steam Systems Save Water and Energy at Naval Air Station Oceana  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Location at NAS Oceana. Location at NAS Oceana. by these changes, including bachelor housing, hangers, the galley, office buildings, the chapel, and maintenance facilities. This ESPC also included installing ground source heat pumps in three buildings, adding digital control systems to increase heating, ventilation and air conditioning (HVAC) efficiency, efficient lighting retrofits, and other water conservation measures. These other water conservation measures include over 5,000 water efficient domestic fixtures, includ- ing faucets, showerheads, and toilets

365

Low-Fuel Compressed Air Energy Storage System Development and Preliminary Evaluation  

Science Conference Proceedings (OSTI)

Compressed air energy storage (CAES) is a valuable solution for mitigating the current challenges of renewable power variability, facilitating future higher renewable penetration levels, enhancing grid reliability and improving the utilization of transmission and existing generation assets. Fuel-based CAES systems are subject to future natural gas price volatility and potential carbon dioxide (CO2) emission charges. Low-Fuel CAES (LFCAES) is a potential near-term technology that captures and stores heat ...

2010-12-17T23:59:59.000Z

366

Impact of cool storage air-conditioning in commercial sector on power system operation in Thailand  

SciTech Connect

The results are presented from an investigation into the potential application for cool storage air-conditioning, and the resultant beneficial impact on power system operation in Thailand is discussed. Field assessment through interviews with decision makers in the identified customer groups produces results that show good potential for cool storage application. Results from a computer program used to calculate power production cost and other characteristics show that substantial benefits would also accrue to the generating utility.

Surapong, C.; Bundit, L. [Asian Inst. of Tech., Bangkok (Thailand)

1997-05-01T23:59:59.000Z

367

Boiler Upgrades and Decentralizing Steam Systems Save Water and Energy at Naval Air Station Oceana  

NLE Websites -- All DOE Office Websites (Extended Search)

Location at NAS Oceana. Location at NAS Oceana. by these changes, including bachelor housing, hangers, the galley, office buildings, the chapel, and maintenance facilities. This ESPC also included installing ground source heat pumps in three buildings, adding digital control systems to increase heating, ventilation and air conditioning (HVAC) efficiency, efficient lighting retrofits, and other water conservation measures. These other water conservation measures include over 5,000 water efficient domestic fixtures, includ- ing faucets, showerheads, and toilets

368

New Automotive Air Conditioning System Simulation Tool Developed in MATLAB/Simulink  

DOE Green Energy (OSTI)

Further improvements in vehicle fuel efficiency require accurate evaluation of the vehicle's transient total power requirement. When operated, the air conditioning (A/C) system is the largest auxiliary load on a vehicle; therefore, accurate evaluation of the load it places on the vehicle's engine and/or energy storage system is especially important. Vehicle simulation software, such as 'Autonomie,' has been used by OEMs to evaluate vehicles' energy performance. A transient A/C simulation tool incorporated into vehicle simulation models would also provide a tool for developing more efficient A/C systems through a thorough consideration of the transient A/C system performance. The dynamic system simulation software Matlab/Simulink was used to develop new and more efficient vehicle energy system controls. The various modeling methods used for the new simulation tool are described in detail. Comparison with measured data is provided to demonstrate the validity of the model.

Kiss, T.; Chaney, L.; Meyer, J.

2013-07-01T23:59:59.000Z

369

Improving Energy Efficiency in Pharmaceutical ManufacturingOperations -- Part I: Motors, Drives and Compressed Air Systems  

Science Conference Proceedings (OSTI)

In Part I of this two-part series, we focus on efficient use of motors, drives and pumps, both for process equipment and compressed air systems. Pharmaceutical manufacturing plants in the U.S. spend nearly $1 billion each year for the fuel and electricity they need to keep their facilities running (Figure 1, below). That total that can increase dramatically when fuel supplies tighten and oil prices rise, as they did last year. Improving energy efficiency should be a strategic goal for any plant manager or manufacturing professional working in the drug industry today. Not only can energy efficiency reduce overall manufacturing costs, it usually reduces environmental emissions, establishing a strong foundation for a corporate greenhouse-gas-management program. For most pharmaceutical manufacturing plants, Heating, Ventilation and Air Conditioning (HVAC) is typically the largest consumer of energy, as shown in Table 1 below. This two-part series will examine energy use within pharmaceutical facilities, summarize best practices and examine potential savings and return on investment. In this first article, we will focus on efficient use of motors, drives and pumps, both for process equipment and compressed air systems. Part 2, to be published in May, will focus on overall HVAC systems, building management and boilers.

Galitsky, Christina; Chang, Sheng-chien; Worrell, Ernst; Masanet,Eric

2006-04-01T23:59:59.000Z

370

The Earth-Coupled or Geothermal Heat Pump Air Conditioning System  

E-Print Network (OSTI)

As utility costs have risen despite political campaign promises and energy conserving measures implemented by the utility companies such as alternative fuel use (coal and nuclear), co-generation, etc., homeowners have begun to search for effective methods of reducing their electricity bills. In some cases homeowners are faced with utility bills That are approaching the cost of their mortgage payments. For those with fixed incomes, such as the elderly or those looking forward to retirement in the near future, this has become an alarming reality. Virtually every homeowner would like to reduce his utility bill but the question is, what items should he address in order to have a significant impact on his electricity costs? According to Houston Lighting h Power Company, 50% of an electricity bill can be attributed to the air conditioning system, and another 15-20% to the hot water heating system. Therefore, to dramatically reduce utility costs one should look first at these two "energy gulpers" and next at proper home insulation, window coverings, etc. The other electrical appliances in the home use relatively minor amounts of electricity compared to the air conditioning and hot water heating system. This paper will describe the geothermal heat pump and the desuperheater as the latest developments in energy efficient air conditioning and water heating.

Wagers, H. L.; Wagers, M. C.

1985-01-01T23:59:59.000Z

371

Air thermosiphon solar heating system: the Jones house, Santa Fe, New Mexico  

DOE Green Energy (OSTI)

A hybrid passive/active solar heating system, featuring a passive air thermosiphon loop, is described. Heated air is supplied to a rock storage bin, coupled with blower-driven air distribution to the house. The house, of 246 m/sup 2/ (2650 ft/sup 2/) heated area and located in Santa Fe, New Mexico, also includes a greenhouse located under the planar collector array. Architectural features and construction details of the house, the solar collector, storage, and distribution system are presented. Representative results of three months of monitoring by the Los Alamos Scientific Laboratory of collector, rock bin, and greenhouse temperatures, as well as outside ambient temperature and insolation, are reported and discussed. Data recorded hourly since the system was placed in operation in early February 1978, show temperatures in the rock bin in excess of 71/sup 0/C (160/sup 0/F) and in the collector absorber mesh in excess of 93/sup 0/C (200/sup 0/F). Delivery temperatures from the charged bin, without auxiliary boost, range from 38 to 54/sup 0/C (100 to 130/sup 0/F).

Hunn, B.D.; Jones, M.M.

1978-01-01T23:59:59.000Z

372

Analysis of the AirTouch automatic vehicle location system's ability to locate moving vehicles  

E-Print Network (OSTI)

Automatic vehicle location systems are becoming more prevalent in diverse transportation applications. Their ability to locate vehicles can assist in locating emergency and public transit vehicles for better real-time dispatching as well as recovering stolen vehicles. Because many applications require traveling vehicles, this thesis focused on the AirTouch system's ability to accurately locate a moving vehicle. Recent AirTouch vehicle location system reports were compiled and analyzed to distinguish what factors tend to affect the accuracy of the readings. Based on the results of the reports, two sites were selected to minimize the external effects that could create inaccurate readings. Six speeds were selected ranging from 0 to 80 kmph (O to 50 mph) in 16 kmph (10 mph) increments. Each velocity was tested 20 times at each site. The location readings were compared to differential Global Positioning System (dGPS) readings which currently provide the most accurate location readings available for civilian use. The dGPS readings were also collected at each test site. It was discovered that one site produced more accurate readings compared to the other site. In addition, the longitude differences accounted for most of the error in the readings. Finally, more error was prevalent in the readings associated with the vehicle's direction of travel as opposed to readings perpendicular to the direction of travel. Based on the data analysis, it was impossible to conclude if velocity affected the accuracy of the AirTouch system. The results of this thesis have suggested that the AirTouch system does decrease in accuracy as the velocity increases among traveling vehicles. However, in one case, the accuracy of the stationary readings were less accurate compared to the non-stationary readings. At 80 kmph (50 mph), AirTouch had an approximate inaccuracy of 50 meters (164 feet). When the data was adjusted for human error, this approximate inaccuracy decreased to 33 meters (107 feet). For transit services, these averages are appropriate. When dispatching a transit vehicle, two-way communication between dispatcher and driver can verify the vehicle's exact location. Furthermore, when a customer needs to know where a vehicle is and when it should arrive, 33 to 50 meters (107 to 164 feet) is sufficient for the customers' needs.

Henry, Tracy Lynn

1995-01-01T23:59:59.000Z

373

Storage/Handling | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

StorageHandling StorageHandling Records Management Procedures for Storage, Transfer & Retrieval of Records from the Washington National Records Center (WNRC) or Legacy Management...

374

T-625: Opera Frameset Handling Memory Corruption Vulnerability | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5: Opera Frameset Handling Memory Corruption Vulnerability 5: Opera Frameset Handling Memory Corruption Vulnerability T-625: Opera Frameset Handling Memory Corruption Vulnerability May 18, 2011 - 3:05pm Addthis PROBLEM: A vulnerability has been reported in Opera, which can be exploited by malicious people to compromise a user's system. PLATFORM: Opera versions prior to 11.11 ABSTRACT: The vulnerability is caused due to an error when handling certain frameset constructs during page unloading and can be exploited to corrupt memory via a specially crafted web page. reference LINKS: Secunia Advisory: SA44611 Opera Knowledge Base Opera 11.11 for Windows Opera Download Opera Mobile IMPACT ASSESSMENT: High Discussion: Framesets allow web pages to hold other pages inside them. Certain frameset constructs are not handled correctly when the page is unloaded, causing a

375

V-217: Microsoft Windows NAT Driver ICMP Packet Handling Denial...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

SCUSSION: The vulnerability is caused due to an error within the Windows NAT Driver when handling ICMP packets and can be exploited to cause the system to stop responding IMPACT:...

376

Energy Basics: Solar Air Heating  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

EERE: Energy Basics Solar Air Heating Solar air heating systems use air as the working fluid for absorbing and transferring solar energy. Solar air collectors (devices to heat air...

377

A genetic rule weighting and selection process for fuzzy control of heating, ventilating and air conditioning systems  

Science Conference Proceedings (OSTI)

In this paper, we propose the use of weighted linguistic fuzzy rules in combination with a rule selection process to develop accurate fuzzy logic controllers dedicated to the intelligent control of heating, ventilating and air conditioning systems concerning ... Keywords: BEMS, building energy management system, FLC, fuzzy logic controller, Fuzzy logic controllers, GA, genetic algorithm, Genetic algorithms, HVAC systems, HVAC, heating, ventilating, and air conditioning, KB, knowledge base, PMV, predicted mean vote index for thermal comfort, Rule selection, Weighted fuzzy rules

Rafael Alcalá; Jorge Casillas; Oscar Cordón; Antonio González; Francisco Herrera

2005-04-01T23:59:59.000Z

378

Influencing Factors on Energy Consumption of Air Conditioning System in Railway Passenger Station Based on Orthogonal Experiment  

Science Conference Proceedings (OSTI)

Orthogonal experiment was used to analyze the energy consumption of air conditioning system, which belongs to four typical passenger stations in four regions, including severe cold region, cold region, hot summer and cold winter region, hot summer and ... Keywords: Railway Passenger Station, Orthogonal Experiment, Air Conditioning Energy Consumption, Energy Conservation

Weiwu Ma; Liqing Li; Suoying He; Jia Cheng; Guijie Huang; Chenn Q. Zhou

2012-01-01T23:59:59.000Z

379

Air core poloidal magnetic field system for a toroidal plasma producing device  

DOE Patents (OSTI)

A poloidal magnetics system for a plasma producing device of toroidal configuration is provided that reduces both the total volt-seconds requirement and the magnitude of the field change at the toroidal field coils. The system utilizes an air core transformer wound between the toroidal field (TF) coils and the major axis outside the TF coils. Electric current in the primary windings of this transformer is distributed and the magnetic flux returned by air core windings wrapped outside the toroidal field coils. A shield winding that is closely coupled to the plasma carries a current equal and opposite to the plasma current. This winding provides the shielding function and in addition serves in a fashion similar to a driven conducting shell to provide the equilibrium vertical field for the plasma. The shield winding is in series with a power supply and a decoupling coil located outside the TF coil at the primary winding locations. The present invention requires much less energy than the usual air core transformer and is capable of substantially shielding the toroidal field coils from poloidal field flux.

Marcus, Frederick B. (Clinton, TN)

1978-01-01T23:59:59.000Z

380

Evaluation of a residential solar air heating system. Interim progress report, August 1976--May 1977. [Comparison of air-type and liquid-type collectors  

SciTech Connect

The comparative performance of Solar House II collectors (air heater) and Solar House I collectors (liquid heater) is presented. In the 1976 comparison year, there is no conclusive evidence that either system provides a greater fraction of the seasonal load. Both systems were designed to provide approximately 75 percent of the annual space and water heating load, and the design targets are reasonably achieved. In February, 1976, the air system provided 65 percent of the total requirement while the liquid system provided 76 percent. In March, based on a few days of data, the performance was substantially the same. In April the air system provided a greater fraction of solar heat to the total need, but the use of the heat was different, more being used for domestic water heating in Solar House I than in Solar House II. The data for 1977 have not yet been fully analyzed for both solar houses and therefore, a complete comparison cannot be made. At this stage in the evaluations, it can be stated that either system can be designed to achieve the target fraction of the total annual heat requirements. (WHK)

Karaki, S.

1977-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Distribution System Audits, Leak Detection, and Repair: Kirtland Air Force Base Leak Detection and Repair Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Best Management Practice Best Management Practice Case Study #3 Distribution System Audits, Leak Detection, and Repair Kirtland Air Force Base - Leak Detection and Repair Program Overview Kirtland Air Force Base (AFB) performed an award winning leak detection and repair program in 2006. The results of the project are saving Kirtland AFB 179 million gallons each year, which is over 16% of the total water use at the base. Kirtland AFB is located on 52,000 acres, southeast and adjacent to Albuquerque, New Mexico. The area is a high altitude desert, only receiving about 8 inches of rain each year. Kirtland AFB draws water from an under- ground aquifer via seven production wells through- out the base. The base also has access to water from the City of Albuquerque. The underground water

382

Distribution System Audits, Leak Detection, and Repair: Kirtland Air Force Base Leak Detection and Repair Program  

NLE Websites -- All DOE Office Websites (Extended Search)

Best Management Practice Best Management Practice Case Study #3 Distribution System Audits, Leak Detection, and Repair Kirtland Air Force Base - Leak Detection and Repair Program Overview Kirtland Air Force Base (AFB) performed an award winning leak detection and repair program in 2006. The results of the project are saving Kirtland AFB 179 million gallons each year, which is over 16% of the total water use at the base. Kirtland AFB is located on 52,000 acres, southeast and adjacent to Albuquerque, New Mexico. The area is a high altitude desert, only receiving about 8 inches of rain each year. Kirtland AFB draws water from an under- ground aquifer via seven production wells through- out the base. The base also has access to water from the City of Albuquerque. The underground water

383

Building Energy Software Tools Directory: DD4M Air Duct Design  

NLE Websites -- All DOE Office Websites (Extended Search)

friction, constant velocity and or static regain procedures to design air ducts for air conditioning, heating, ventilation and materials handling. Allows 1000 duct sections...

384

ESS 2012 Peer Review - Modular Undersea Compressed Air Energy Storage (UCAES) System - James Kesseli, Brayton Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

solar.energy.gov/sunshot/csp.html solar.energy.gov/sunshot/csp.html ENERGY STORAGE SYSTEMS: Sept. 27, 2012 Modular Undersea Compressed Air Energy Storage (UCAES) System Bill Caruso www.BraytonEnergy.com Brayton Energy LLC Project Overview UCAES has the potential to offer modular, grid scale storage capability at competitive costs when coupled with high efficiency power conversion systems. The nature of the design minimizes vessel stress and aesthetic impact, while utilizing readily available material and construction techniques. Progress Future Work Further feasibility and cost studies must be conducted by experienced maritime construction contractors. The market for UCAES systems must be explored further by conducting broader case studies of bathymetry, terrain, infrastructure and natural and/or renewable energy resource potential.

385

Selection of the most advantageous gas turbine air filtration system: Comparative study of actual operating experience  

SciTech Connect

This paper discusses relative merits of three types of air filtration systems used by Sui Northern Gas Pipelines Ltd. (Pakistan), on its gas turbine compressor packages. These Filtration systems are: (i) Two stage inertial plus auto oil bath type multi-duty filters by AAF used on Saturn Mark-1 packages manufactured by Solar Turbines Inc. (ii) Three stage high efficiency barrier filters by AAF used on Centaur packages by Solar. (iii) Single stage pulse-jet self-cleaning filter by Donaldson again used on a Centaur package. The selection is primarily based in package performance data collected over a 15 month period analyzing power loss due to fouling effects and related operation and maintenance costs for the three systems. The Company's operating experience indicates that on new installations the pulse clean system offers the best advantage both in terms of filtration costs as well as availability of additional horse power when operating under moderate to severe environmental conditions.

Gilani, S.I.; Mehr, M.Z.

1985-01-01T23:59:59.000Z

386

Experimental investigation on the photovoltaic-thermal solar heat pump air-conditioning system on water-heating mode  

Science Conference Proceedings (OSTI)

An experimental study on operation performance of photovoltaic-thermal solar heat pump air-conditioning system was conducted in this paper. The experimental system of photovoltaic-thermal solar heat pump air-conditioning system was set up. The performance parameters such as the evaporation pressure, the condensation pressure and the coefficient of performance (COP) of heat pump air-conditioning system, the water temperature and receiving heat capacity in water heater, the photovoltaic (PV) module temperature and the photovoltaic efficiency were investigated. The experimental results show that the mean photovoltaic efficiency of photovoltaic-thermal (PV/T) solar heat pump air-conditioning system reaches 10.4%, and can improve 23.8% in comparison with that of the conventional photovoltaic module, the mean COP of heat pump air-conditioning system may attain 2.88 and the water temperature in water heater can increase to 42 C. These results indicate that the photovoltaic-thermal solar heat pump air-conditioning system has better performances and can stably work. (author)

Fang, Guiyin; Hu, Hainan; Liu, Xu [Department of Physics, Nanjing University, Nanjing 210093 (China)

2010-09-15T23:59:59.000Z

387

Technology transition in the national air transportation system : market failure and game theoretic analysis with application to ADS-B  

E-Print Network (OSTI)

This research analyzes the problem of technology transition in the national air transportation system, focusing on the implementation of Automatic Dependent Surveillance-Broadcast (ADS-B). ADS-B is a key technology in the ...

Hu, Xiaojie

2008-01-01T23:59:59.000Z

388

Computer program development specification for the air traffic control subsystem of the Man-Vehicle Systems Research Facility.  

E-Print Network (OSTI)

Functional summary: The Air Traffic Control (ATC) Subsystem of the Man-Vehicle System Research Facility (MVSRF) is a hardware/software complex which provides the MVSRF with the capability of simulating the multi-aircraft, ...

Massachusetts Institute of Technology. Flight Transportation Laboratory

1982-01-01T23:59:59.000Z

389

Dal-Tile: Optimized Compressed Air System Improves Performance and Saves Energy at a Tile Manufacturing Plant  

SciTech Connect

This DOE Industrial Technologies Program case study describes the significant energy and costs savings resulting from compressed air system improvements at Dal-Tile, a Texas tile manufacturing plant.

2005-08-01T23:59:59.000Z

390

The Australian Air Quality Forecasting System. Part III: Case Study of a Melbourne 4-Day Photochemical Smog Event  

Science Conference Proceedings (OSTI)

A 4-day photochemical smog event in the Melbourne, Victoria, Australia, region (6–9 March 2001) is examined to assess the performance of the Australian Air Quality Forecasting System (AAQFS). Although peak ozone concentrations measured during ...

K. J. Tory; M. E. Cope; G. D. Hess; S. Lee; K. Puri; P. C. Manins; N. Wong

2004-05-01T23:59:59.000Z

391

Guidelines for Induced Flue Gas Recirculation: Volume 1: Reducing Air/Gas System Resistance and Enhancing Fan Capacity  

Science Conference Proceedings (OSTI)

This document guides users through a logical sequence, or "road map," of activities and decisions for optimizing solutions for fans, ducts, and related equipment in fossil plant combustion air and gas systems.

1999-12-13T23:59:59.000Z

392

On the Aerosol Particle Size Distribution Spectrum in Alaskan Air Mass Systems: Arctic Haze and Non-Haze Episodes  

Science Conference Proceedings (OSTI)

Aerosols in central Alaskan winter air mass system were classified according to size by diffusive separation and light-scattering spectrometry. Particles entering central Alaska from the Pacific Marine environment had number concentrations ...

Glenn E. Shaw

1983-05-01T23:59:59.000Z

393

Duct Systems in large commercial buildings: Physical characterization, air leakage, and heat conduction gains  

E-Print Network (OSTI)

A variety of methods of sealing supply-air registers wereand sealing practices when leakage at connections to duct-mounted equipment is not considered. The measured air-

Fisk, W.J.

2011-01-01T23:59:59.000Z

394

Handbook for Handling, Storing, and Dispensing E85 | Open Energy  

Open Energy Info (EERE)

for Handling, Storing, and Dispensing E85 for Handling, Storing, and Dispensing E85 Jump to: navigation, search Tool Summary Name: Handbook for Handling, Storing, and Dispensing E85 Agency/Company /Organization: National Renewable Energy Laboratory Focus Area: Fuels & Efficiency Topics: Best Practices Website: www.afdc.energy.gov/afdc/pdfs/48162.pdf This document serves as a guide for blenders, distributors, sellers, and users of E85 as an alternative motor fuel. It provides basic information on the proper and safe use of E85 and offers supporting technical and policy references. How to Use This Tool This tool is most helpful when using these strategies: Avoid - Cut the need for travel Shift - Change to low-carbon modes Improve - Enhance infrastructure & policies Learn more about the avoid, shift, improve framework for limiting air

395

Tritium Handling and Safe Storage  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

SENSITIVE DOE-HDBK-1129-2007 March 2007 ____________________ DOE HANDBOOK TRITIUM HANDLING AND SAFE STORAGE U.S. Department of Energy AREA SAFT Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. DOE-HDBK-1129-2007

396

Portable vacuum object handling device  

SciTech Connect

The disclosure relates to a portable device adapted to handle objects which are not to be touched by hand. A piston and bore wall form a vacuum chamber communicating with an adaptor sealably engageable with an object to be lifted. The piston is manually moved and set to establish vacuum. A valve is manually actuatable to apply the vacuum to lift the object.

Anderson, Gordon H. (Los Alamos, NM)

1983-08-09T23:59:59.000Z

397

Photon Sciences Material Handling Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

Active Y Y Rhein Craig 20622 PSBC Active Y Y Page 3 of 80 List of Photon Sciences Mat'l Handling Equip 5242013 4:09:58 PM 725 UV East GE-56 PS-C01 Yale A-422-3749 2 ton...

398

Portable vacuum object handling device  

DOE Patents (OSTI)

The disclosure relates to a portable device adapted to handle objects which are not to be touched by hand. A piston and bore wall form a vacuum chamber communicating with an adaptor sealably engageable with an object to be lifted. The piston is manually moved and set to establish vacuum. A valve is manually actuable to apply the vacuum to lift the object.

Anderson, G.H.

1981-07-30T23:59:59.000Z

399

Temperature decoupling control of double-level air flow field dynamic vacuum system based on neural network and prediction principle  

Science Conference Proceedings (OSTI)

Double-level air flow field dynamic vacuum (DAFDV) system is a strong coupling, large time-delay, and nonlinear multi-input-multi-output system. Decoupling and overcoming the impact of time-delay are two keys to obtain rapid, accurate and independent ... Keywords: ASSAVP, BP, DAFDV, Decoupling control, Double-level air flow field, EBTC, HX, IPSO, MIMO, Neural networks, OIF, PID, Particle swarm optimization, Prediction, RBF, SISO, TITO, WBTC

Li Jinyang; Meng Xiaofeng

2013-04-01T23:59:59.000Z

400

Vehicle cabin cooling system for capturing and exhausting heated boundary layer air from inner surfaces of solar heated windows  

DOE Patents (OSTI)

The cabin cooling system includes a cooling duct positioned proximate and above upper edges of one or more windows of a vehicle to exhaust hot air as the air is heated by inner surfaces of the windows and forms thin boundary layers of heated air adjacent the heated windows. The cabin cooling system includes at least one fan to draw the hot air into the cooling duct at a flow rate that captures the hot air in the boundary layer without capturing a significant portion of the cooler cabin interior air and to discharge the hot air at a point outside the vehicle cabin, such as the vehicle trunk. In a preferred embodiment, the cooling duct has a cross-sectional area that gradually increases from a distal point to a proximal point to the fan inlet to develop a substantially uniform pressure drop along the length of the cooling duct. Correspondingly, this cross-sectional configuration develops a uniform suction pressure and uniform flow rate at the upper edge of the window to capture the hot air in the boundary layer adjacent each window.

Farrington, Robert B. (Golden, CO); Anderson, Ren (Broomfield, CO)

2001-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Program on Technology Innovation: Adiabatic Compressed Air Energy Storage Systems for Renewable Energy Integration  

Science Conference Proceedings (OSTI)

This report summarizes the status and progress of the research, development, and demonstration (RD&D) work at the Electric Power Research Institute (EPRI) on adiabatic no-fuel compressed air energy storage (CAES) for wind integration. Bulk energy storage (BES) is necessary to provide grid damping in order to mitigate wind power variability. The objective of adiabatic no-fuel CAES RD&D is to combine the lowest-cost BES option (which is CAES) with carbon-free operation. The research focuses on system desig...

2010-11-08T23:59:59.000Z

402

Selection of Light Duty Truck Engine Air Systems Using Virtual Lab Tests  

DOE Green Energy (OSTI)

An integrated development approach using seasoned engine technology methodologies, virtual lab parametric investigations, and selected hardware verification tests reflects today's state-of-the-art R&D trends. This presentation will outline such a strategy. The use of this ''Wired'' approach results in substantial reduction in the development cycle time and hardware iterations. An example showing the virtual lab application for a viable design of the air-exhaust-turbocharger system of a light duty truck engine for personal transportation will be presented.

Zhang, Houshun

2000-08-20T23:59:59.000Z

403

Solutions for Summer Electric Power Shortages: Demand Response andits Applications in Air Conditioning and Refrigerating Systems  

SciTech Connect

Demand response (DR) is an effective tool which resolves inconsistencies between electric power supply and demand. It further provides a reliable and credible resource that ensures stable and economical operation of the power grid. This paper introduces systematic definitions for DR and demand side management, along with operational differences between these two methods. A classification is provided for DR programs, and various DR strategies are provided for application in air conditioning and refrigerating systems. The reliability of DR is demonstrated through discussion of successful overseas examples. Finally, suggestions as to the implementation of demand response in China are provided.

Han, Junqiao; Piette, Mary Ann

2007-11-30T23:59:59.000Z

404

A prototype system for detecting the radio-frequency pulse associated with cosmic ray air showers  

E-Print Network (OSTI)

The development of a system to detect the radio-frequency (RF) pulse associated with extensive air showers of cosmic rays is described. This work was performed at the CASA/MIA array in Utah, with the intention of designing equipment that can be used in conjunction with the Auger Giant Array. A small subset of data (less than 40 out of a total of 600 hours of running time), taken under low-noise conditions, permitted upper limits to be placed on the rate for pulses accompanying showers of energies around $10^{17}$ eV.

Kevin Green; Jonathan L. Rosner; Denis A. Suprun; J. F. Wilkerson

2002-05-03T23:59:59.000Z

405

Air Distribution and Microenvironment Evaluation of a Desktop Task Conditioning System  

E-Print Network (OSTI)

Task conditioning aims to provide each occupant with personalized clean air direct to the breathing zone. The microenvironment of a typical office workplace, consisting of two desktop task conditioning systems (a Horizontal Desk Grill (HDG) and Vertical Desk Grill (VDG)) were studied by numerical simulation. Numerical simulation by k- 3-D turbulent flow was separately conducted to study the influence of supply velocity on the microenvironment of these two desktop task conditioning systems. Three task conditioning velocities were studied. Temperature and velocity distribution, Draught Rating (DR) and Predicted Percentage of Dissatisfied (PPD) of the room and workstation were applied to study the performance of task air conditioning. Results show that the performances of HDG and VDG are almost the same. Results also show that task conditioning can provide excellent working environment when supply velocity is well designed. The supply velocity of task conditioning can be set between 0.8-1.0 m/s. However, task conditioning may cause draught, and engineers should seriously consider this problem. The results can provide important references for design and optimization of the task conditioning system.

Zheng, G.

2006-01-01T23:59:59.000Z

406

Fuzzy expert system design for operating room air-condition control systems  

Science Conference Proceedings (OSTI)

In this study, a controlled fuzzy expert system (FES) was designed to provide the conditions necessary for operating rooms. For this purpose, existing operating rooms have been studied to see if there are more useful, reliable and comfortable ones. How ... Keywords: Adaptive fuzzy control, Expert systems, Fuzzy control systems, Operating room control

Nazmi Etik; Novruz Allahverdi; Ibrahim Unal Sert; Ismail Saritas

2009-08-01T23:59:59.000Z

407

Energy Comparison Between Conventional and Chilled Water Thermal Storage Air Conditioning Systems  

E-Print Network (OSTI)

During the summer of previous years, Kuwait faced a series of power shortages emphasizing the need for urgent commissioning of power generation projects. It is estimated that the demand for electricity is growing at an average of 6.2% per year, encouraged by government subsidies and driven by the rapid and continual expansion in building construction, urban development, and the heavy reliance on Air Conditioning (AC) systems for the cooling of buildings. The Chilled Water Thermal Storage (CWTS) system is one of the available techniques that can be utilized to reduce peak electricity demand of buildings when national electricity consumption is at its highest level. This paper demonstrates that the use of CWTS system reduces the peak power demand and energy consumption of AC systems for design day conditions by 36.7% - 87.5% and 5.4% - 7.2%, respectively. This reduction depends on selected operating strategies as compared with conventional AC system. Furthermore, results show that the annual energy consumption of CWTS systems decreases by between 4.5% and 6.9% compared with conventional systems, where chillers and pumps significantly contribute to this reduction.

Sebzali, M.; Hussain, H. J.; Ameer, B.

2010-01-01T23:59:59.000Z

408

Development of a model to calculate mechanical specific energy for air hammer drilling systems  

E-Print Network (OSTI)

Drilling for hydrocarbons is an expensive operation; consequently operators try to save costs by reducing the number of days spent during this operation. Drilling efficiently with the highest attainable rate of penetration is one of the ways drilling time could be reduced. Real-time monitoring of Mechanical Specific Energy will enable drilling engineers to detect when the optimum drilling rate for a given set of drilling parameters is not being achieved. Numerous works have been done on air hammers and rock Mechanical Specific Energy. Previous research has shown that Mechanical Specific Energy, which is a ratio that quantifies the input energy and Rate of Penetration (ROP) of a drilling system, is directly proportional to the rock compressive strength being drilled. The Mechanical Specific Energy model utilizes drilling parameters such as ROP, Weight on bit (WOB), RPM, torque, flow-rate, bottom-hole pressure, and bottom-hole temperature to show how effectively energy being put into the drill string is being converted to ROP at the bit. This research effort proposes a new model to calculate the Mechanical Specific Energy for air hammer drilling systems. A thermodynamic model for the air hammer from which the piston impact velocity and kinetic energy is obtained is presented. To be able to estimate the effective energy delivered to the rock by the hammer, the stress wave propagation model is used and factored into the Mechanical Specific Energy model. The Mechanical Specific Energy values obtained from the application of this model provide a qualitative indicator of formation pressure changes and a means for drilling engineers to detect when optimum drilling rate is not being achieved. It can be deduced from the model that the impact energy of the hammer is greatly affected by the pressure drop across the hammer and since the hammer accounts for about sixty percent of the energy required for destroying the rock, the ROP can be varied by varying the pressure drop across the hammer.

Okuchaba, Boma Jeremiah

2008-05-01T23:59:59.000Z

409

Proprties of the Carrol system and a machine design for solar-powered, air-cooled, absorption space cooling. Phase I and Phase II. Final report, September 1977-March 1979  

DOE Green Energy (OSTI)

The name Carrol has been selected as a convenient short-hand designation for a prime candidate chemical system comprising ethylene glycol-lithium bromide as an absorbent mixture with water as a refrigerant. The instrumentation, methods of handling data and numerical results from a systematic determination of Carrol property data required to design an air cooled absorption machine based on this chemical system are described. These data include saturation temperature, relative enthalpy, density, specific heat capacity, thermal conductivity, viscosity and absorber film heat transfer coefficient as functions of solution temperature and Carrol concentration over applicable ranges. For each of the major components of the absorption chiller, i.e., generator, chiller, absorber, condenser, heat exchanger, purge and controls, the report contains an assembly drawing and the principal operating characteristics of that component.

Biermann, W.J.

1981-05-01T23:59:59.000Z

410

Technical and economic assessment of fluidized-bed-augmented compressed-air energy-storage system: system load following capability  

DOE Green Energy (OSTI)

The load-following capability of fluidized bed combustion-augmented compressed air energy storage systems was evaluated. The results are presented in two parts. The first part is an Executive Summary which provides a concise overview of all major elements of the study including the conclusions, and, second, a detailed technical report describing the part-load and load following capability of both the pressurized fluid bed combustor and the entire pressurized fluid bed combustor/compressed air energy storage system. The specific tasks in this investigation were to: define the steady-state, part-load operation of the CAES open-bed PFBC; estimate the steady-state, part-load performance of the PFBC/CAES system and evaluate any possible operational constraints; simulate the performance of the PFBC/CAES system during transient operation and assess the load following capability of the system; and establish a start-up procedure for the open-bed PFBC and evaluate the impact of this procedure. The conclusions are encouraging and indicate that the open-bed PFBC/CAES power plant should provide good part-load and transient performance, and should have no major equipment-related constraints, specifically, no major problems associated with the performance or design of either the open-end PFBC or the PFBC/CAES power plant in steady-state, part-load operation are envisioned. The open-bed PFBC/CAES power plant would have a load following capability which would be responsive to electric utility requirements for a peak-load power plant. The open-bed PFBC could be brought to full operating conditions within 15 min after routine shutdown, by employing a hot-start mode of operation. The PFBC/CAES system would be capable of rapid changes in output power (12% of design load per minute) over a wide output power range (25% to 100% of design output). (LCL)

Lessard, R.D.; Blecher, W.A.; Merrick, D.

1981-09-01T23:59:59.000Z

411

Technical and economic assessment of fluidized bed augmented compressed air energy storage system. Volume III. Preconceptual design  

DOE Green Energy (OSTI)

A technical and economic assessment of fluidized bed combustion augmented compressed air energy storage systems is presented. The results of this assessment effort are presented in three volumes. Volume III - Preconceptual Design contains the system analysis which led to the identification of a preferred component configuration for a fluidized bed combustion augmented compressed air energy storage system, the results of the effort which transformed the preferred configuration into preconceptual power plant design, and an introductory evaluation of the performance of the power plant system during part-load operation and while load following.

Giramonti, A.J.; Lessard, R.D.; Merrick, D.; Hobson, M.J.

1981-09-01T23:59:59.000Z

412

Thermal decay in underfloor air distribution (UFAD) systems: Fundamentals and influence on system performance  

E-Print Network (OSTI)

Inc. , 2004. ASHRAE Fundamentals Handbook, Chapter 14,distribution (UFAD) systems: Fundamentals and influence onwas used to explain the fundamentals of thermal decay, to

Lee, Kwang Ho; Schiavon, Stefano; Bauman, Fred; Webster, Tom

2012-01-01T23:59:59.000Z

413

Tritium Handling and Safe Storage  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE-HDBK-1129-2008 December 2008 DOE HANDBOOK TRITIUM HANDLING AND SAFE STORAGE U.S. Department of Energy AREA SAFT Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. TS DOE-HDBK-1129-2008 ii This page is intentionally blank. DOE-HDBK-1129-2008 iii TABLE OF CONTENTS SECTION PAGE FOREWORD................................................................................................................................ ix ACRONYMS ................................................................................................................................ xi 1.0 INTRODUCTION ....................................................................................................................

414

Portable vacuum object handling device  

DOE Patents (OSTI)

The disclosure relates to a portable device adapted to handle objects which are not to be touched by hand. A piston and bore wall form a vacuum chamber communicating with an adaptor sealably engageable with an object to be lifted. The piston is manually moved and set to establish vacuum. A valve is manually actuatable to apply the vacuum to lift the object. 1 fig.

Anderson, G.H.

1983-08-09T23:59:59.000Z

415

Candidate chemical systems for air cooled, solar powered, absorption air conditioner design. Part II. Solid absorbents, high latent heat refrigerants  

DOE Green Energy (OSTI)

Work done in attempting to qualify absorption refrigeration systems based on refrigerants with intermediate latent heats of vaporization is summarized. In practice, these comprise methanol, ammonia, and methylamine. A wide variety of organic substances, salts, and mixtures were evaluated in as systematic a manner as possible. Several systems of interest are described. The system, LiClO/sub 3/--LiBr--H/sub 2/O, is a good back up system to our first choice of an antifreeze additive system, and thermodynamically promising but subject to some inconvenient materials limitations. The system, LiBr/ZnBr/sub 2/--methanol, is thermodynamically promising but requires additional kinetic qualification. Chemical stability of the system, LiCNS--ammonia/methylamine with various other third components, does not appear to be adequate for a long-lived system.

Biermann, W. J.

1978-04-01T23:59:59.000Z

416

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System  

SciTech Connect

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade (SOG) home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

Burdick, A.

2013-10-01T23:59:59.000Z

417

Commissioning Tools for Heating/Cooling System in Residence - Verification of Floor Heating System and Room Air Conditioning System Performance  

E-Print Network (OSTI)

Tools of evaluating the performance of floor heating and room air conditioner are examined as a commissioning tool. Simple method is needed to check these performance while in use by residents, because evaluation currently requires significant time and effort. Therefore, this paper proposes a) two methods of evaluating the floor heating efficiency from the room / crawl space temperature and the energy consumption and b) method of evaluating COP of the room air conditioner from the data measured at the external unit. Case studies in which these tools were applied to actual residences are presented to demonstrate their effectiveness.

Miura, H.; Hokoi, S.; Iwamae, A.; Umeno, T.; Kondo, S.

2004-01-01T23:59:59.000Z

418

Introducing a Partitioning Mechanism for PAHs into the Community Multiscale Air Quality Modeling System and Its Application to Simulating the Transport of Benzo(a)pyrene over Europe  

Science Conference Proceedings (OSTI)

Into the Community Multiscale Air Quality modeling system (CMAQ) that is widely used for simulating the transport and fate of air pollutants, a new module was inserted that accounts for the partitioning of semivolatile organic compounds—in ...

Armin Aulinger; Volker Matthias; Markus Quante

2007-11-01T23:59:59.000Z

419

Dynamic Response of a Rotor-air Bearing System Due to Base Induced Periodic Motions  

E-Print Network (OSTI)

Oil-free microturbomachinery (MTM) are inevitably subjected to base or foundation excitations: multiple periodic load excitations from internal combustion (IC) engines in turbochargers, for example. Too large base excitations can produce severe damage, even failure, due to hard collision or rubbing contact between a rotor and its bearings. Therefore, it is paramount to evaluate the reliability of rotor-air bearing systems to withstanding base load excitations. In 2008, intermittent shock excitations, up to 30 g (pk-pk), were introduced to a test rig consisting of a rotor (0.825 kg) supported on two hybrid flexure pivot tilting pad gas bearings (FPTPBs). The experiments demonstrated the reliability of the gas bearings to withstanding external transient load excitations. Presently, a shaker delivers periodic load excitations to the base plate supporting the test rig. The whole system, weighing 48 kg, is supported on two soft coil springs and its lowest natural frequency is ~5 Hz. The rod connecting the shaker to the base plate is not affixed rigidly to the test rig base. The rod merely pushes on the base plate and hence the induced based motions are intermittent with multiple impacts and frequencies. As with most practical conditions, the base motion frequencies (5-12 Hz) are low respective to the operating speed of the rotor-bearing system. Rotor speed coast down tests evidence the rotor-bearing system natural frequency when the gas bearings are supplied with feed pressures increasing from 2.36 to 5.08 bar (ab). Shaker excitation induced rotor response, relative to the bearing housings, contains the main input frequency (5-12 Hz) and its super harmonics; and because of the intermittency of the base motions, it also excites the rotor-bearing system natural frequency, with smaller motion amplitudes than synchronous motion components. The excitation of the system natural frequency does not mean rotordynamic instability. With base induced motions, the rotor motion amplitude at the system natural frequency increases as the gas bearing feed pressure decreases, as the rotor speed increases, and as the shaker input excitation frequency increases (5-12 Hz). Hence, the test rotor-air bearing system is highly sensitive to base motions, intermittent in character, in particular when the gas bearings are supplied with a low feed pressure. Predicted rotor motion responses obtained from XLTRC2 and an analytical rigid rotor model, both including the (measured) periodic base motions, show good correlation with the measurements. The research results demonstrate further the applicability of gas bearings into oil-free high speed MTM.

Niu, Yaying

2009-08-01T23:59:59.000Z

420

Improving Energy Efficiency of Compressed Air System Based on System Audit  

E-Print Network (OSTI)

be a significant source of wasted energy in an industrialto being a source of wasted energy and money, leaks can alsofor about 3.2% of system energy wasted. Figure 5 Excessive

Shanghai, Hongbo Qin; McKane, Aimee

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

DOE N 435.1, Contact-Handled and Remote-Handled Transuranic Waste Packaging  

Directives, Delegations, and Requirements

Provides specific instructions for packaging and/or repackaging contact-handled transuranic (CH-TRU) and remote-handled transuranic (RH-TRU) waste in a manner ...

2011-08-15T23:59:59.000Z

422

Results from Field Testing of Embedded Air Handling Unit and ...  

Science Conference Proceedings (OSTI)

... Tzone = zone temperature CSP = cooling set point HSP ... types, building uses, and weather conditions based on ... the faults and their impact on the ...

2006-11-13T23:59:59.000Z

423

Improvement of air handling unit control performance using reinforcement learning  

Science Conference Proceedings (OSTI)

Most common applications using neural networks for control problems are the automatic controls using the artificial perceptual function. These control mechanisms are similar to those of the intelligent and pattern recognition control of an adaptive method ...

Sangjo Youk; Moonseong Kim; Yangsok Kim; Gilcheol Park

2006-08-01T23:59:59.000Z

424

Duct Systems in large commercial buildings: Physical characterization, air leakage, and heat conduction gains  

E-Print Network (OSTI)

Air Leakage, and Heat Conduction Gains William 1. Fisk,0.75 to 0.90; thus, heat conduction decreased the coolingby air leakage or heat conduction, because these ducts are

Fisk, W.J.

2011-01-01T23:59:59.000Z

425

ASE/CAGI Meeting about Compressors and Compressed Air System Efficiency  

Energy.gov (U.S. Department of Energy (DOE))

On April 25, 2013, several representatives of energy efficiency advocacy organizations met with staff and members of the Compressed Air and Gas Institute (CAGI) along with some compressed air...

426

An Airborne Laser Air Motion Sensing System. Part I: Concept and Preliminary Experiment  

Science Conference Proceedings (OSTI)

Measurement of air motion relative to an aircraft by a conically scanned optical Doppler technique has advantages over measurements with conventional gust probes for many applications. Advantages of the laser air motion sensing technique ...

R. J. Keeler; R. J. Serafin; R. L. Schwiesow; D. H. Lenschow; J. M. Vaughan; A. A. Woodfield

1987-03-01T23:59:59.000Z

427

Analysis of a Radome Air-Motion System on a Twin-Jet Aircraft for Boundary-Layer Research  

Science Conference Proceedings (OSTI)

A “radome gust probe” system was installed on a twin-jet aircraft for the purpose of boundary-layer research. This system provided a useful relatively low-cost method for air motion and turbulence measurements on an aircraft already equipped with ...

Michael Tjernström; Carl A. Friehe

1991-02-01T23:59:59.000Z

428

Abstract--A novel compressed air energy storage system for wind turbine is proposed. It captures excess power prior to  

E-Print Network (OSTI)

Abstract-- A novel compressed air energy storage system for wind turbine is proposed. It captures of simulation case studies demonstrate the operation of the system. I. INTRODUCTION enewable energy such as wind and solar energy are clean and available as long as the wind blows or sun shines. Two main disadvantages

Li, Perry Y.

429

Pacific Gas and Electric Company's Compressed Air Management Program: A Performance Assessment Approach to Improving Industrial Compressed Air System Operation and Maintenance  

E-Print Network (OSTI)

The Compressed Air Management Program (CAMP) provides Pacific Gas and Electric's (PG&E's) large industrial customers with measurement-based performance assessments of their compressed air systems. Under this program, the customer's system is inspected and both short-term, high resolution, and longer-term measurements are taken of power and pressure. These data are used in developing a system simulation based on the US DOE's AIRMaster+ computer model. Model results and professional judgment are used to identify a cost-effective strategy for improving the system. Recommendations are provided to the customer along with technical support for implementing these recommendations. After improvements are complete, the performance measurements are repeated so that PG&E and its customers can judge the effectiveness of the recommendations. The program uses a standardized toolkit (all off-the-shelf components) along with software developed exclusively for this application, to accomplish the required measurements and efficiently analyze and reduce the data for use in the AIRMaster+ model.

Qualmann, R. L.; Zeller, W.; Baker, M.

2002-04-01T23:59:59.000Z

430

The Remote-Handled TRU Waste Program  

SciTech Connect

RH TRU Waste is radioactive waste that requires shielding in addition to that provided by the container to protect people nearby from radiation exposure. By definition, the radiation dose rate at the outer surface of the container is greater than 200 millirem per hour and less than 1,000 rem per hour. The DOE is proposing a process for the characterization of RH TRU waste planned for disposal in the WIPP. This characterization process represents a performance-driven approach that satisfies the requirements of the New Mexico Hazardous Waste Act, the Environmental Protection Agency (EPA) regulations for WIPP long-term performance, the transportation requirements of the Nuclear Regulatory Commission (NRC) and the Department of Transportation, as well as the technical safety requirements of RH TRU waste handling. The transportation, management and disposal of RH TRU waste is regulated by external government agencies as well as by the DOE itself. Externally, the characterization of RH-TRU waste for disposal at the WIPP is regulated by 20.4.1.500 New Mexico Administrative Code (incorporating 40 CFR 261.13) for the hazardous constituents and 40 CFR 194.24 for the radioactive constituents. The Nuclear Regulatory Commission certifies the shipping casks and the transportation system must meet DOT regulations. Internally, the DOE evaluates the environmental impacts of RH TRU waste transportation, handling and disposal through its National Environmental Policy Act program. The operational safety is assessed in the RH TRU Waste Safety Analysis Report, to be approved by the DOE. The WIPP has prepared a modification request to the Hazardous Waste Facility Permit that includes modifications to the WIPP facility for the safe receipt and handling of RH TRU waste and the addition of an RH TRU waste analysis plan. Modifications to the facility include systems and equipment for safe handling of RHTRU containers. Two shipping casks are to be used to optimize RH TRU was te throughput: the RH-72B and the CNS 10-160B transportation casks. Additionally, a draft Notification of Proposed Change to the EPA 40 CFR 194 Certification of the WIPP has been prepared, which contains a proposal for the RH TRU characterization program for compliance with the EPA requirements.

Gist, C. S.; Plum, H. L.; Wu, C. F.; Most, W. A.; Burrington, T. P.; Spangler, L. R.

2002-02-26T23:59:59.000Z

431

Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems  

DOE Green Energy (OSTI)

This paper presents a freely available Modelica library for building heating, ventilation and air conditioning systems. The library is based on the Modelica.Fluid library. It has been developed to support research and development of integrated building energy and control systems. The primary applications are controls design, energy analysis and model-based operation. The library contains dynamic and steady-state component models that are applicable for analyzing fast transients when designing control algorithms and for conducting annual simulations when assessing energy performance. For most models, dimensional analysis is used to compute the performance for operating points that differ from nominal conditions. This allows parameterizing models in the absence of detailed geometrical information which is often impractical to obtain during the conceptual design phase of building systems. In the first part of this paper, the library architecture and the main classes are described. In the second part, an example is presented in which we implemented a model of a hydronic heating system with thermostatic radiator valves and thermal energy storage.

Wetter, Michael

2009-06-17T23:59:59.000Z

432

Technology assessment report for the Soyland Power Cooperative, Inc. compressed air energy storage system (CAES)  

DOE Green Energy (OSTI)

The design and operational features of compressed air energy storage systems (CAES) in general and, specifically, of a proposed 220 MW plant being planned by the Soyland Power Cooperative, Inc. in Illinois are described. This technology assessment discusses the need for peaking capacity, CAES requirements for land, fuel, water, and storage caverns, and compares the costs, environmental impacts and licensing requirements of CAES with those of power plants using simple cycle or combined cycle combustion turbines. It is concluded that during the initial two years of CAES operation, the CAES would cost more than a combustion turbine or combined cycle facility, but thereafter the CAES would have a increasing economic advantage; the overall environmental impact of a CAES plant is minimal, and that there should be no great difficulties with CAES licensing. (LCL)

Not Available

1982-01-01T23:59:59.000Z

433

Low-pressure reservoir drilled with air/N[sub 2] in a closed system  

Science Conference Proceedings (OSTI)

Ignition tests on simulated produced fluids helped determine the ideal air/nitrogen mixture for an underbalanced drilling operation that used a closed surface system to process return fluids. The low-pressure, heavy-oil target reservoir required underbalanced drilling to minimize formation damage. Underbalanced or near-balanced drilling can improve production from pressure-depleted reservoirs by reducing the chance of formation damage from drilling fluid losses. Underbalanced drilling technology currently available includes the use of gas injection through parasite strings or through drilling tubulars. No one (to the author's knowledge) has combined concentric-string commingled gas injection with through-drilling-tubular commingled gas injection. The paper describes lab work, test results, surface returns, downhole design, operations, and field results.

Teichrob, R.R. (Husky Oil Operations Ltd., Calgary, Alberta (Canada))

1994-03-21T23:59:59.000Z

434

Evaluation of mixing downstream of tees in duct systems with respect to single point representative air sampling  

E-Print Network (OSTI)

Air duct systems in nuclear facilities must meet the requirements of ANSI N13.1-1999 and the Environmental Protection Agency (EPA) that the exhaust airflow be monitored with continuous sampling in case of an accidental release of airborne radionuclides. The continuous air sampling in a duct system is based on the concept of single point representative sampling at the sampling location where the velocity and contaminant profiles are nearly uniform. Sampling must be at a location where there is a uniform distribution via mixing in accordance with ANSI N13.1-1999. The purpose of this work is to identify the sampling locations where the velocity, momentum and contaminant concentrations fall below the 20% coefficient of variation (COV) requirements of ANSI N13.1-1999. Four sets of experiments were conducted on a generic 'T' mixing system. Measurements were made of the velocity, tracer gas concentration, ten micrometer particles and average flow swirl angle. The generic 'T' mixing system included three different combinations of sub duct sizes (6"x6", 9"x9" and 12"x12"), one main duct size (12"x12") and five air velocities (0, 100, 200, 300, and 400 fpm). An air blender was also introduced in some of the tests to promote mixing of the air streams from the main duct and sub duct. The experimental results suggested a turbulent mixing provided the accepted velocity COVs by 6 hydraulic diameters downstream. For similar velocity in the main duct and sub duct, an air blender provided the substantial improvement in 3 hydraulic diameters needed to achieve COVs below 10%. Without an air blender, the distance downstream of the T-junction for the COVs below 20% increased as the velocity of the sub duct airflow increased. About 95% of the cases achieved COVs below 10%. With the air blender, most of the cases with the air blender had the lower COVs than without the blender. However, at an area ratio (sub duct area / main duct area) of 0.25 and above a velocity ratio (velocity in the sub duct / velocity in the main duct) of 3, the air blender proved to be less beneficial for mixing. These results can apply to other duct systems with similar geometries and, ultimately, be a basis for selecting a proper sampling location under the requirements of the single point representative sampling.

Kim, Taehong

2003-01-01T23:59:59.000Z

435

Alpha and gamma radiation effects on air-water systems at high gas/liquid ratios  

SciTech Connect

Radiolysis tests were conducted on air-water systems to examine the effects of radiation on liquid phase chemistry under high gas/liquid volume (G/L) ratios that are characteristic of an unsaturated nuclear waste repository setting. Test parameters included temperatures of 25, 90, and 200{degrees}C; gamma vs. alpha radiation; dose rates of {approximately}3500 and 50,000 rad/h; and G/L ratios of 10 and 100. Formate, oxalate, and total organic carbon contents increased during irradiation of the air-water systems in gamma and alpha tests at low-dose rate ({approximately}3500 rad/h). Increases in organic components were not observed for tests run at 200{degrees}C or high-dose rates (50,000 rad/h). In the tests where increases in organics occurred, the formate and oxalate were preferentially enriched in solutions that were rinsed from the test vessel walls. Nitrate (NO{sub 3}{sup {minus}}) is the dominant anion produced during the radiolysis reactions. Significant nitrite (NO{sub 2}{sup {minus}}) also occurs in some high-dose rate tests, with the reduced form of nitrogen possibly resulting from reactions with the test vessels. These results indicate that nitrogen acids are being produced and concentrated in the limited quantities of solution present in the tests. Nitrate + nitrite production varied inversely with temperature, with the lowest quantities being detected for the higher temperature tests. The G(NO{sub 3}{sup {minus}} + NO{sub 2}{sup {minus}}) values for the 25, 90, and 200{degrees}C experiments with gamma radiation are 3.2 {+-} 0.7, 1.3 {+-} 1.0, and 0.4 {+-} 0.3, respectively. Thus, the elevated temperatures expected early in the life of a repository may counteract pH decreases resulting from nitrogen acid production. Little variation was observed in G values as a function of dose rate or gas/liquid ratio.

Wronkiewicz, D.J.; Bates, J.K.

1993-08-01T23:59:59.000Z

436

Comparative performance of solar heating with air and liquid systems. Interim progress report, February 1, 1976--August 30, 1976  

SciTech Connect

A performance comparison between an air solar system and a liquid solar system for space heating under nearly equal conditions has been obtained. The Colorado State University Solar House I is a liquid solar system which has been in operation since August 1974. Solar House II, which stands adjacent to and has a comparable heating load to Solar House I, is equipped with an air solar system. Solar House I has been continuously monitored since August 1974 and Solar House II has been monitored since February 1976. Performance of the solar systems is reported in terms of the collector efficiency, the amount of space heating and service water heating load provided by solar energy, and the use of electrical energy to operate the solar equipment. General characteristics of the two types of systems are also compared. Information concerning installation, operation, and maintenance of the systems have been documented and are discussed.

Karaki, S.; Lof, G.O.G.; Smith, C.C.

1976-08-01T23:59:59.000Z

437

Uranium hexafluoride: A manual of good handling practices. Revision 7  

SciTech Connect

The United States Enrichment Corporation (USEC) is continuing the policy of the US Department of Energy (DOE) and its predecessor agencies in sharing with the nuclear industry their experience in the area of uranium hexafluoride (UF{sub 6}) shipping containers and handling procedures. The USEC has reviewed Revision 6 or ORO-651 and is issuing this new edition to assure that the document includes the most recent information on UF{sub 6} handling procedures and reflects the policies of the USEC. This manual updates the material contained in earlier issues. It covers the essential aspects of UF{sub 6} handling, cylinder filling and emptying, general principles of weighing and sampling, shipping, and the use of protective overpacks. The physical and chemical properties of UF{sub 6} are also described. The procedures and systems described for safe handling of UF{sub 6} presented in this document have been developed and evaluated during more than 40 years of handling vast quantities of UF{sub 6}. With proper consideration for its nuclear properties, UF{sub 6} may be safely handled in essentially the same manner as any other corrosive and/or toxic chemical.

NONE

1995-01-01T23:59:59.000Z

438

WIPP Remote Handled Waste Facility: Performance Dry Run Operations  

SciTech Connect

The Remote Handled (RH) TRU Waste Handling Facility at the Waste Isolation Pilot Plant (WIPP) was recently upgraded and modified in preparation for handling and disposal of RH Transuranic (TRU) waste. This modification will allow processing of RH-TRU waste arriving at the WIPP site in two different types of shielded road casks, the RH-TRU 72B and the CNS 10-160B. Washington TRU Solutions (WTS), the WIPP Management and Operation Contractor (MOC), conducted a performance dry run (PDR), beginning August 19, 2002 and successfully completed it on August 24, 2002. The PDR demonstrated that the RHTRU waste handling system works as designed and demonstrated the handling process for each cask, including underground disposal. The purpose of the PDR was to develop and implement a plan that would define in general terms how the WIPP RH-TRU waste handling process would be conducted and evaluated. The PDR demonstrated WIPP operations and support activities required to dispose of RH-TRU waste in the WIPP underground.

Burrington, T. P.; Britain, R. M.; Cassingham, S. T.

2003-02-24T23:59:59.000Z

439

Air Leakage of Furnaces and Air Handlers  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Leakage of Furnaces and Air Handlers Air Leakage of Furnaces and Air Handlers Title Air Leakage of Furnaces and Air Handlers Publication Type Journal Article LBNL Report Number LBNL-5553E Year of Publication 2010 Authors Walker, Iain S., Mile Lubliner, Darryl J. Dickerhoff, and William W. Delp Journal 2010 ACEEE Summer Study on Energy Efficiency in Buildings The Climate for efficiency is now Date Published 08/2010 Abstract In recent years, great strides have been made in reducing air leakage in residential and to a lesser extent small commercial forced air duct systems. Several authorities have introduced low leakage limits for thermal distribution systems; for example, the State of California Energy Code for Buildings gives credit for systems that leak less than 6% of the total air flow at 25 Pa.

440

Hybrid energy storage systems based on compressed air and supercapacitors with maximum efficiency point tracking  

E-Print Network (OSTI)

This paper presents a hybrid energy storage system based on Compressed Air Energy Storage (CAES), where the charging and discharging is done within maximum efficiency conditions. As the maximum efficiency conditions impose the level of converted power, an intermittent time-modulated operation mode is applied to the thermodynamic converter to obtain a variable converted power. A smoothly variable output power is achieved with the help of a supercapacitive auxiliary storage device used as a filter. The paper describes the concept of the system, the power-electronic interface circuits and especially the Maximum Efficiency Point Tracking (MEPT) algorithm and the strategy used to vary the output power. In addition, the paper will present the characteristics of a high efficiency storage device where the pure pneumatic machine is replaced by an oil-hydraulics and pneumatics converter, used under isothermal conditions. Practical results are also presented, recorded from a low-power pneumatic motor coupled to a small DC generator, as well as from a first prototype of the final hydraulic/pneumatic system.

Sylvain Lemofouet; Alfred Rufer

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air handling system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Energy Consumption Measuring and Diagnostic Analysis of Air-conditioning Water System in a Hotel Building in Harbin  

E-Print Network (OSTI)

This paper introduces an air-conditioning water system in a hotel building in Harbin, finishes its air-conditioning energy consumption measurement in summer conditions, and presents an estimation index of performance of chiller, pump and motor. By means of testing data analysis, it is indicated that several problems such as unsuitable operation schedule of the chiller, low COP, irrational matching of pump and motor, unbalanced conditions of chilled water flow, and low working stability and efficiency ratio of the pump are existent. The paper presents suggestions for improvement with relevance based on the induction and analysis of system fault found in measurements.

Zhao, T.; Zhang, J.; Li, Y.

2006-01-01T23:59:59.000Z

442

Technical and economic assessment of fluidized-bed-augmented compressed-air energy-storage system. Volume I. Executive summary  

DOE Green Energy (OSTI)

An energy storage system which could be attractive for future electric utility peak-load applications is a modified gas turbine power system utilizing underground storage of very high pressure air. The compressed air energy storage (CAES) concept involves using off-peak electricity generated from indigenous coal or nuclear sources to compress air, storing the air in large underground facilities, and withdrawing the air during peak-load periods when it would be heated by combustion and expanded through gas turbines to generate power. The attractiveness of the CAES concept is based upon its potential to supply competitively priced peaking energy, to reduce peak-load power plant dependence on petroleum-based fuels, and to provide a means for leveling the utility system load demand. Therefore, a technical and economic assessment of coal-fired fluidized bed (FBC) combustor/compressed air energy storage (FBC/CAES) systems was performed and is described. The conclusions drawn from the FBC/CAES study program are encouraging. They indicate that pressurized FBC/CAES power plants should be technologically feasible, provide good performance, and be economically competitive. Specifically, it is concluded that: coal-fired FBC/CAES systems should be technically feasible in the near future and potentially attractive for peak-load power generation; and an open-bed PFBC/CAES configuration would provide the best candidate for early commercialization. It has relatively low risk combined with moderate cost and reasonable round-trip heat rate. It also has the potential for future growth options which tend to reduce costs and lower fuel consumption.

Giramonti, A.J.; Lessard, R.D.; Merrick, D.; Hobson, M.J.

1981-09-01T23:59:59.000Z

443

GUIDE TO CALCULATING TRANSPORT EFFICIENCY OF AEROSOLS IN OCCUPATIONAL AIR SAMPLING SYSTEMS  

SciTech Connect

This report will present hand calculations for transport efficiency based on aspiration efficiency and particle deposition losses. Because the hand calculations become long and tedious, especially for lognormal distributions of aerosols, an R script (R 2011) will be provided for each element examined. Calculations are provided for the most common elements in a remote air sampling system, including a thin-walled probe in ambient air, straight tubing, bends and a sample housing. One popular alternative approach would be to put such calculations in a spreadsheet, a thorough version of which is shared by Paul Baron via the Aerocalc spreadsheet (Baron 2012). To provide greater transparency and to avoid common spreadsheet vulnerabilities to errors (Burns 2012), this report uses R. The particle size is based on the concept of activity median aerodynamic diameter (AMAD). The AMAD is a particle size in an aerosol where fifty percent of the activity in the aerosol is associated with particles of aerodynamic diameter greater than the AMAD. This concept allows for the simplification of transport efficiency calculations where all particles are treated as spheres with the density of water (1 g?cm-3). In reality, particle densities depend on the actual material involved. Particle geometries can be very complicated. Dynamic shape factors are provided by Hinds (Hinds 1999). Some example factors are: 1.00 for a sphere, 1.08 for a cube, 1.68 for a long cylinder (10 times as long as it is wide), 1.05 to 1.11 for bituminous coal, 1.57 for sand and 1.88 for talc. Revision 1 is made to correct an error in the original version of this report. The particle distributions are based on activity weighting of particles rather than based on the number of particles of each size. Therefore, the mass correction made in the original version is removed from the text and the calculations. Results affected by the change are updated.

Hogue, M.; Hadlock, D.; Thompson, M.; Farfan, E.

2013-11-12T23:59:59.000Z

444

Depleted UF6 Production and Handling Slide Presentation  

NLE Websites -- All DOE Office Websites (Extended Search)

Production and Handling Depleted UF6 Production and Handling Slide Presentation An online slide presentation about production and handling of depleted UF6, from mining of uranium...

445

Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure  

E-Print Network (OSTI)

Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure

2012-01-01T23:59:59.000Z

446

Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel  

E-Print Network (OSTI)

Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel

2012-01-01T23:59:59.000Z

447

Development of standardized air-blown coal gasifier/gas turbine concepts for future electric power systems. Volume 1, Final report  

Science Conference Proceedings (OSTI)

The objective of this study is to develop standardized air blown fixed bed gasification hot gas cleanup integrated gasifier combined cycle (IGCC) systems.

Sadowski, R.S.; Brown, M.J.; Hester, J.C.; Harriz, J.T.; Ritz, G.J.

1991-02-01T23:59:59.000Z

448

A multi-objective evolutionary algorithm for an effective tuning of fuzzy logic controllers in heating, ventilating and air conditioning systems  

Science Conference Proceedings (OSTI)

This paper focuses on the use of multi-objective evolutionary algorithms to develop smartly tuned fuzzy logic controllers dedicated to the control of heating, ventilating and air conditioning systems, energy performance, stability and indoor comfort ... Keywords: Fuzzy logic controllers, Genetic tuning, HVAC systems, Heating, ventilating, and air conditioning systems, Linguistic 2-tuples representation, Multi-objective evolutionary algorithms, Rule selection

María José Gacto; Rafael Alcalá; Francisco Herrera

2012-03-01T23:59:59.000Z

449

Program on Technology Innovation: Materials Selection for Compressed Air Energy Storage System  

Science Conference Proceedings (OSTI)

EPRI is evaluating materials compatibility issues as they relate to aboveground compressed air energy storage (CAES) pipelines. The factors determining materials performance include pressure and thermal cycling; adiabatic cooling as pressurized air is released, causing condensation of water and corrosion; and any gaseous impurities in the air affecting corrosion. This report focuses on evaluation of corrosion behavior and provides a systematic decision-making approach to the selection of appropriate mate...

2009-12-21T23:59:59.000Z

450

CANISTER HANDLING FACILITY DESCRIPTION DOCUMENT  

Science Conference Proceedings (OSTI)

The purpose of this facility description document (FDD) is to establish requirements and associated bases that drive the design of the Canister Handling Facility (CHF), which will allow the design effort to proceed to license application. This FDD will be revised at strategic points as the design matures. This FDD identifies the requirements and describes the facility design, as it currently exists, with emphasis on attributes of the design provided to meet the requirements. This FDD is an engineering tool for design control; accordingly, the primary audience and users are design engineers. This FDD is part of an iterative design process. It leads the design process with regard to the flowdown of upper tier requirements onto the facility. Knowledge of these requirements is essential in performing the design process. The FDD follows the design with regard to the description of the facility. The description provided in this FDD reflects the current results of the design process.

J.F. Beesley

2005-04-21T23:59:59.000Z

451

Energy Saving System to Remove Volatile Organic Compounds (VOCs) from Indoor Air  

Scientists at Berkeley Lab have developed a catalyst and deployment devices to improve indoor air quality and reduce ventilation energy needs.

452

Study of a solar-assisted air conditioning system for South Africa.  

E-Print Network (OSTI)

??In South Africa, a significant amount of electrical energy is used for air conditioning in commercial buildings, on account of the high humidity experienced. Due… (more)

Joseph, Jerusha Sarah.

2012-01-01T23:59:59.000Z

453

The Coordinated Control of a Central Air Conditioning System Based on Variable Chilled Water Temperature and Variable Chilled Water Flow  

E-Print Network (OSTI)

At present, regulation of water flow by means of pump frequency conversion is one of the major methods for power-saving in central air conditioning systems. In this article, optimization regulation for central air conditioning system on the basis of coordinative optimization control for variable chilled water temperature and variable chilled water flow to obtain better power savings is put forward. According to typical meteorological year data, hourly air conditioning load of whole year for every typical room has been calculated with the transmission function method. In order to guarantee each typical room, the highest cooling load rate is used as an input parameter for optimization calculation. Based on the surface cooler check model, the smallest energy consumption of chiller and chiller water pump was taken as the objective function of the optimization model. The performance characteristics of a chiller, water pump, regulation valve and pipeline are taken into account, and the optimization chilled water temperature and chilled water flow were carried out. The case study for a commercial building in Guangzhou showed that the annual power consum