Powered by Deep Web Technologies
Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Improving Air Conditioner and Heat Pump Modeling  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Improving Air-Conditioner Improving Air-Conditioner and Heat Pump Modeling Building America Stakeholders Meeting Jon Winkler March 2, 2012 2 * How do you recommend the most cost-effective A/C? Simple Question 3 Solution Whole-House Simulation Tool A/C Information * SEER 13 * SEER 14 * SEER 15 * SEER 16 * SEER 17 * SEER 18 * SEER 21 Annualized Cooling Cost (Energy + Equipment) 4 Background * Power, capacity and SHR vary with: o Outdoor temperature o Entering wetbulb o Air mass flow rate o Part load ratio Power Sensible Capacity Latent Capacity * How to accurately and easily model A/C performance? 5 Background: Model Development * A/C modeling utilizes two types of input o Rated values (capacity, efficiency, etc.) o Performance curves Capacity 1 / Efficiency 6 Background: Manufacturer's Data

2

Central Air Conditioners","Heat Pumps","Individual Air Conditioners...  

U.S. Energy Information Administration (EIA) Indexed Site

4,89,294,9,26,327,47,4 "District Heat ...",96,77,3,4,16,39,15,35,"Q","Q" "Boilers ...",581,474,58,39,211,3,96,223,18,14 "Packaged Heating Units...

3

Inverter control systems in the residential heat pump air conditioner  

SciTech Connect

A compressor capacity control with an inverter has been considered from the viewpoint of high energy saving in a refrigerating cycle. However, the system has not been put into practical use because of high initial cost, technical problems of electronic parts, and complexity of system control. In this connection, we developed the new inverter-controlled heat-pump air conditioner by using the latest electronics and refrigeration technology. This paper discusses the trend of energy saving in air conditioners in Japan and the objectives of developing the inverter controlled air conditioner. It also discusses the following items with respect to the inverter controlled air conditioner and the effects of employing an inverter: 1. Inverter for air conditioning; 2. Refrigeration cycle; 3. Air conditioner control with inverter.

Shimma, Y.; Tateuchi, T.; Suglura, H.

1985-01-01T23:59:59.000Z

4

Improving Air-Conditioner and Heat Pump Modeling (Presentation)  

SciTech Connect

A new approach to modeling residential air conditioners and heat pumps allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted 'behind-the-scenes' without negatively impacting the reliability of energy simulations.

Winkler, J.

2012-03-01T23:59:59.000Z

5

Improving Air-Conditioner and Heat Pump Modeling (Presentation)  

SciTech Connect

A new approach to modeling residential air conditioners and heat pumps allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted 'behind-the-scenes' without negatively impacting the reliability of energy simulations.

Winkler, J.

2012-03-01T23:59:59.000Z

6

Development of solar driven absorption air conditioners and heat pumps  

DOE Green Energy (OSTI)

The objective of this project is the development of absorption refrigeration systems for solar active heating and cooling applications. The approaches being investigated are those using air-cooled condenser-absorbers and those leading to coefficient of performances (COP) that increase continuously with heat source temperature. This is primarily an experimental project, with the emphasis on designing, fabricating and testing absorption chillers in operating regimes that are particularly suited for solar energy applications. The first phase of this project has been concluded and has experimentally demonstrated that the conventional single-effect ammonia-water absorption cycle can be used (with minor modifications) for solar cooling. The second phase of this project explores the commercial potential of the single-effect (SE) NH/sub 3//H/sub 2/O absorption air conditioner. (WHK)

Dao, K.; Wahlig, M.; Wali, E.; Rasson, J.; Molishever, E.

1980-03-01T23:59:59.000Z

7

Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations  

SciTech Connect

This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost effective equipment upgrade opportunities and efficiency improvements in residential buildings.

Cutler, D.; Winkler, J.; Kruis, N.; Christensen, C.; Brendemuehl, M.

2013-01-01T23:59:59.000Z

8

air conditioner | OpenEI  

Open Energy Info (EERE)

air conditioner air conditioner Dataset Summary Description View 2010 energy efficiency data from AeroSys Inc, Coaire, Cold Point, First Operations, LG Electronics, Nordyne, and Quietside manufacturers. Data includes cooling capacity, cooling performance, heating capacity, and heating performance. Spreadsheet was created by combining the tables in pdf files that are included in the zip file. Source Energy Applicance Data - United States Federal Trade Commission, www.ftc.gov Date Released Unknown Date Updated Unknown Keywords air conditioner central air conditioner efficiency efficient energy heat pump Data application/vnd.ms-excel icon 2010_CentralAC_All.xls (xls, 82.4 KiB) application/zip icon 2010CentralAirConditioner.zip (zip, 398.2 KiB) Quality Metrics Level of Review Some Review

9

DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Manufacturers to Halt Sales of Heat Pumps and Air Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards June 3, 2010 - 2:17pm Addthis Today, the Department of Energy announced that three manufacturers -- Aspen Manufacturing, Inc., Summit Manufacturing, and Advanced Distributor Products -- must stop distributing 61 heat pump models and 1 air conditioner model that DOE has determined do not comply with federal energy conservation standards. The manufacturers also must notify all of their customers that have been sold noncompliant units. The Department determined that these models were noncompliant based on certification information submitted to DOE for these manufacturers.

10

DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Requires Manufacturers to Halt Sales of Heat Pumps and Air Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards June 3, 2010 - 2:17pm Addthis Today, the Department of Energy announced that three manufacturers -- Aspen Manufacturing, Inc., Summit Manufacturing, and Advanced Distributor Products -- must stop distributing 61 heat pump models and 1 air conditioner model that DOE has determined do not comply with federal energy conservation standards. The manufacturers also must notify all of their customers that have been sold noncompliant units. The Department determined that these models were noncompliant based on certification information submitted to DOE for these manufacturers.

11

DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Requires Manufacturers to Halt Sales of Heat Pumps and Air Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards June 3, 2010 - 12:00am Addthis Washington, DC - Today, the Department of Energy announced that three manufacturers -- Aspen Manufacturing, Inc., Summit Manufacturing, and Advanced Distributor Products -- must stop distributing 61 heat pump models and 1 air conditioner model that DOE has determined do not comply with federal energy conservation standards. The manufacturers also must notify all of their customers that have been sold noncompliant units. The Department determined that these models were noncompliant based on certification information submitted to DOE for these manufacturers.

12

Adsorption air conditioner  

DOE Patents (OSTI)

A solar powered air conditioner using the adsorption process is constructed with its components in a nested cylindrical array for compactness and ease of operation.

Rousseau, Jean L. I. (Redondo Beach, CA)

1979-01-01T23:59:59.000Z

13

Room Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

of Superefficient Room Air Conditioners year month keywords appliance energy efficiency energy efficiency incentives Market Transformation standards url https isswprod lbl gov...

14

13 SEER Standard for Central Air Conditioners and Heat Pumps (released in AEO2005)  

Reports and Publications (EIA)

In January 2004, after years of litigation in a case that pitted environmental groups and Attorneys General from 10 States against the U.S. Secretary of Energy, the U.S. Court of Appeals for the Second Circuit reestablished the central air conditioner and heat pump standard originally set in January 2001 [3]. The Courts ruling, which struck down a May 2002 rollback of the 2001 standard to a 12 SEER, mandates that all new central air conditioners and heat pumps meet a 13 SEER standard by January 2006, requiring a 30-percent increase in efficiency relative to current law. The AEO2005 reference case incorporates the 13 SEER standard as mandated by the Courts ruling.

Information Center

2005-04-01T23:59:59.000Z

15

Flicker Reduction Technology for Electric Heat Pumps and Central Air Conditioners  

Science Conference Proceedings (OSTI)

Electric heat pumps and air conditioners move thermal energy into and/or out of conditioned spaces. During startup, the compressor motor temporarily draws high current (inrush) from the power distribution system to accelerate the compressor from standstill to its nominal operating speed. The inrush current causes a voltage drop in the power distribution system between the compressor motor and the utility service transformer. Although very brief in durationjust fractions of a secondthe voltage drop can ca...

2011-12-28T23:59:59.000Z

16

DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS  

E-Print Network (OSTI)

the Annual DOE Active Solar Heating and Cooling Contractors'and Annual DOE Active Solar Heating and Cooling Contractors'refrigeration systems for solar active heating and cooling

Dao, K.

2013-01-01T23:59:59.000Z

17

RESIDENTIAL AIR CONDITIONER FINNED-TUBE CONDENSER HEAT EXCHANGER OPTIMIZATION  

E-Print Network (OSTI)

With the upcoming ban on the production of R-22 in 2010, residential air-conditioning equipment will need to be redesigned with a more environmentally benign working fluid. R-410a is a strong candidate for replacing R-22. A model of an air-conditioning system with a focus on the finned-tube condenser design details using R-410a as the working fluid is developed. An optimization algorithm is implemented to find the optimal condenser design with various constraints for an efficiency figure of merit. The software developed is appropriate for engineering design use in the air-conditioning industry.

Susan W. Stewart; Kristinn A. Aspelund; Monifa F. Wright; Emma M. Sadler; Sam V. Shelton, Ph.D.

2002-01-01T23:59:59.000Z

18

Four Central Air Conditioners Determined Noncompliant With Energy...  

NLE Websites -- All DOE Office Websites (Extended Search)

Action Against AeroSys, Inc. for Failure to Certify Air Conditioners and Heat Pumps DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump...

19

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network (OSTI)

ground water source), electrically operated, unitary central air conditioners and central air conditioning heat pumps

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

20

central air conditioner | OpenEI  

Open Energy Info (EERE)

central air conditioner central air conditioner Dataset Summary Description View 2010 energy efficiency data from AeroSys Inc, Coaire, Cold Point, First Operations, LG Electronics, Nordyne, and Quietside manufacturers. Data includes cooling capacity, cooling performance, heating capacity, and heating performance. Spreadsheet was created by combining the tables in pdf files that are included in the zip file. Source Energy Applicance Data - United States Federal Trade Commission, www.ftc.gov Date Released Unknown Date Updated Unknown Keywords air conditioner central air conditioner efficiency efficient energy heat pump Data application/vnd.ms-excel icon 2010_CentralAC_All.xls (xls, 82.4 KiB) application/zip icon 2010CentralAirConditioner.zip (zip, 398.2 KiB) Quality Metrics Level of Review Some Review

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump...

22

Central Air conditioners | Open Energy Information  

Open Energy Info (EERE)

Page Edit History Facebook icon Twitter icon Central Air conditioners Jump to: navigation, search TODO: Add description List of Central Air conditioners Incentives Retrieved...

23

Stirling Air Conditioner for Compact Cooling  

Science Conference Proceedings (OSTI)

BEETIT Project: Infinia is developing a compact air conditioner that uses an unconventional high efficient Stirling cycle system (vs. conventional vapor compression systems) to produce cool air that is energy efficient and does not rely on polluting refrigerants. The Stirling cycle system is a type of air conditioning system that uses a motor with a piston to remove heat to the outside atmosphere using a gas refrigerant. To date, Stirling systems have been expensive and have not had the right kind of heat exchanger to help cool air efficiently. Infinia is using chip cooling technology from the computer industry to make improvements to the heat exchanger and improve system performance. Infinia痴 air conditioner uses helium gas as refrigerant, an environmentally benign gas that does not react with other chemicals and does not burn. Infinia痴 improvements to the Stirling cycle system will enable the cost-effective mass production of high-efficiency air conditioners that use no polluting refrigerants.

None

2010-09-01T23:59:59.000Z

24

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Room Air Conditioners Room Air Conditioners Room Air Conditioners July 1, 2012 - 5:35pm Addthis A window air conditioner is one solution to cooling part of a house. | Photo courtesy of テつゥiStockphoto/kschulze. A window air conditioner is one solution to cooling part of a house. | Photo courtesy of ツゥiStockphoto/kschulze. What does this mean for me? Room air conditioners are less expensive and disruptive to install than central air conditioning systems. Room air conditioners can be a cost-effective alternative to central air conditioning systems. How does it work? Room air conditioners work by cooling one part of your home. Room or window air conditioners cool rooms rather than the entire home or business. If they provide cooling only where they're needed, room air conditioners are less expensive to operate than central units, even though

25

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

SciTech Connect

In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER.

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-10-10T23:59:59.000Z

26

The Impact of Codes, Regulations, and Standards on Split-Unitary Air Conditioners and Heat Pumps, 65,000 Btu/hr and Under  

Science Conference Proceedings (OSTI)

This document establishes a framework for understanding the technology and regulation of split-unitary air conditioners and heat pumps 65,000 Btu/hr and under. The reporting framework is structured so that it can be added to in the future. This study is broken into six chapters:The basic components, refrigeration cycle, operation, and efficiency ratings of split-unitary air conditioners and heat pumps are covered for background information.Equipment efficiency ...

2012-09-21T23:59:59.000Z

27

Analysis of Efficiency Standards for Air Conditioners, Air ...  

U.S. Energy Information Administration (EIA)

Federal agencies to select ENERGY STAR and ... analyze the proposed air conditioner and heat pump standards, a new baseline ... square foot office building 0.4 to 0.8 ...

28

Modeled and measured effects of compressor downsizing in an existing air conditioner/heat pump in the cooling mode  

SciTech Connect

It is not uncommon to find oversized central air conditioners in residences. HVAC contractors sometimes oversize central air conditioners for one reason or another--some to the point that they may be 100% larger than needed to meet the load. Retrofit measures done to improve house envelope and distribution system efficiency also contribute to HVAC oversizing, as they reduce house heating and cooling loads. Proper sizing of an air conditioner or heat pump allows more efficient operation and provides a more comfortable environment than a highly oversized unit. Another factor that lowers operating efficiency is an improper refrigerant charge. Field inspections have revealed that about half of the units checked were not properly charged. An option available to homeowners with oversized air conditioners is to replace the existing compressor with a smaller, more efficient compressor, rather than purchasing a new, smaller unit. Such a retrofit may be economically justified, especially during a compressor failure, provided the oversizing of the existing unit is not too great. A used, 15-year old, single-package heat pump with a capillary tube expansion device on the indoor coil was purchased and tested in a set of environmental chambers to determine its cooling performance at various conditions. The system was also modeled to estimate its existing performance, and that with two different types of retrofitted state-of-the-art (SOA) efficient compressors with about 30% less capacity than the original compressor. This reduced the overall system cooling capacity by about 25%. Modeling estimated that the retrofit would increase system EER at 95 F by 30%, SEER by 34%, and reduce power demand by 39% compared to the existing unit. Reduced cycling losses account for the higher increase in SEER.

Levins, W.P.; Rice, C.K.; Baxter, V.D.

1996-05-01T23:59:59.000Z

29

New and Underutilized Technology: Liquid Desiccant Air Conditioner |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Liquid Desiccant Air Conditioner Liquid Desiccant Air Conditioner New and Underutilized Technology: Liquid Desiccant Air Conditioner October 4, 2013 - 4:40pm Addthis The following information outlines key deployment considerations for liquid desiccant air conditioners (LDACs) within the Federal sector. Benefits Liquid desiccant air conditioners deeply dry air using natural gas, solar energy, waste heat, bio-fuel, or other fossil fuels to drive the system. By providing mostly latent cooling, the LDAC controls indoor humidity without overcooling and reheating. This unit is supplemented by an electric chiller or DX air conditioner that sensibly cools the building's recirculation air. The liquid desiccant is a concentrated salt solution that directly absorbs moisture. Application LDACs are applicable in hospital, office, prison, school, and service

30

Maintaining Your Air Conditioner | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Maintaining Your Air Conditioner Maintaining Your Air Conditioner Maintaining Your Air Conditioner June 18, 2013 - 6:20pm Addthis Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of テつゥiStockphoto/firemanYU. Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ツゥiStockphoto/firemanYU. What does this mean for me? Regular maintenance keeps your air conditioner running as efficiently as possible. Maintaining your air conditioner will save you money by extending the unit's life. An air conditioner's filters, coils, and fins require regular maintenance for the unit to function effectively and efficiently throughout its years of service. Neglecting necessary maintenance ensures a steady decline in air conditioning performance while energy use steadily increases.

31

Maintaining Your Air Conditioner | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Maintaining Your Air Conditioner Maintaining Your Air Conditioner Maintaining Your Air Conditioner June 18, 2013 - 6:20pm Addthis Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of テつゥiStockphoto/firemanYU. Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ツゥiStockphoto/firemanYU. What does this mean for me? Regular maintenance keeps your air conditioner running as efficiently as possible. Maintaining your air conditioner will save you money by extending the unit's life. An air conditioner's filters, coils, and fins require regular maintenance for the unit to function effectively and efficiently throughout its years of service. Neglecting necessary maintenance ensures a steady decline in air conditioning performance while energy use steadily increases.

32

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models...

33

Common Air Conditioner Problems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Common Air Conditioner Problems Common Air Conditioner Problems Common Air Conditioner Problems May 30, 2012 - 6:41pm Addthis A refrigerant leak is one common air conditioning problem. | Photo courtesy of テつゥiStockphoto/BanksPhotos. A refrigerant leak is one common air conditioning problem. | Photo courtesy of ツゥiStockphoto/BanksPhotos. What does this mean for me? You can eliminate the most common air conditioner problems before hiring an air conditioning technician. You can do some air conditioner maintenance and repair tasks yourself. One of the most common air conditioning problems is improper operation. If your air conditioner is on, be sure to close your home's windows and outside doors. For room air conditioners, isolate the room or a group of connected rooms as much as possible from the rest of your home.

34

Common Air Conditioner Problems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Common Air Conditioner Problems Common Air Conditioner Problems Common Air Conditioner Problems May 30, 2012 - 6:41pm Addthis A refrigerant leak is one common air conditioning problem. | Photo courtesy of テつゥiStockphoto/BanksPhotos. A refrigerant leak is one common air conditioning problem. | Photo courtesy of ツゥiStockphoto/BanksPhotos. What does this mean for me? You can eliminate the most common air conditioner problems before hiring an air conditioning technician. You can do some air conditioner maintenance and repair tasks yourself. One of the most common air conditioning problems is improper operation. If your air conditioner is on, be sure to close your home's windows and outside doors. For room air conditioners, isolate the room or a group of connected rooms as much as possible from the rest of your home.

35

Central Air Conditioners","Heat Pumps","Individual Air Conditioners","District Chilled Water","Central Chillers","Packaged  

U.S. Energy Information Administration (EIA) Indexed Site

5. Cooling Equipment, Floorspace, 1999" 5. Cooling Equipment, Floorspace, 1999" ,"Total Floorspace (million square feet)" ,"All Buildings","All Cooled Buildings","Cooling Equipment (more than one may apply)" ,,,"Residential-Type Central Air Conditioners","Heat Pumps","Individual Air Conditioners","District Chilled Water","Central Chillers","Packaged Air Conditioning Units","Swamp Coolers","Other" "All Buildings ................",67338,58474,8329,9147,14276,2750,12909,36527,2219,1312 "Building Floorspace" "(Square Feet)" "1,001 to 5,000 ...............",6774,4879,890,700,962,"Q","Q",2613,253,"Q" "5,001 to 10,000 ..............",8238,6212,1606,707,1396,"Q","Q",3197,181,"Q"

36

Energy savings and economics of advanced control strategies for packaged air conditioners with gas heat  

Science Conference Proceedings (OSTI)

This paper presents an evaluation of the potential energy savings from adding advanced control to existing packaged air conditioners. Advanced control options include air-side economizer, multi-speed fan control, demand control ventilation and staged cooling. The energy and cost savings from the different control strategies individually and in combination are estimated using the EnergyPlus detailed energy simulation program for four building types, namely, a small office building, a stand-alone retail building, a strip mall building and a supermarket building. For each of the four building types, the simulation was run for 16 locations covering all 15 climate zones in the U.S. The maximum installed cost of a replacement controller that provides acceptable payback periods to owners is estimated.

Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

2013-10-01T23:59:59.000Z

37

List of Room Air Conditioners Incentives | Open Energy Information  

Open Energy Info (EERE)

Conditioners Incentives Conditioners Incentives Jump to: navigation, search The following contains the list of 112 Room Air Conditioners Incentives. CSV (rows 1 - 112) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility Nonprofit Schools State Government Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Water Heaters Commercial Cooking Equipment Commercial Refrigeration Equipment Room Air Conditioners Yes Alexandria Light and Power - Residential Energy Efficiency Rebate Program (Minnesota) Utility Rebate Program Minnesota Residential Central Air conditioners

38

Tips: Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips: Air Conditioners Tips: Air Conditioners Tips: Air Conditioners June 24, 2013 - 6:31pm Addthis Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of テつゥiStockphoto/galinast. Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ツゥiStockphoto/galinast. Buying a bigger room air conditioner won't necessarily make you feel more comfortable during the hot summer months. In fact, a room air conditioner that's too big for the area it is supposed to cool will perform less efficiently and less effectively than a smaller, properly sized unit. The reason: an oversized unit will cool the room(s) to the thermostat set-point before proper dehumidification occurs, making the area feel "clammy"

39

Tips: Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips: Air Conditioners Tips: Air Conditioners Tips: Air Conditioners June 24, 2013 - 6:31pm Addthis Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of テつゥiStockphoto/galinast. Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ツゥiStockphoto/galinast. Buying a bigger room air conditioner won't necessarily make you feel more comfortable during the hot summer months. In fact, a room air conditioner that's too big for the area it is supposed to cool will perform less efficiently and less effectively than a smaller, properly sized unit. The reason: an oversized unit will cool the room(s) to the thermostat set-point before proper dehumidification occurs, making the area feel "clammy"

40

DOE/EA-1352: Environmental Assessment for Proposed Energy Conservation Standards for Residential Central Air Conditioners and Heat Pumps (12/00)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

52 52 ENVIRONMENTAL ASSESSMENT FOR PROPOSED ENERGY CONSERVATION STANDARDS FOR RESIDENTIAL CENTRAL AIR CONDITIONERS AND HEAT PUMPS December 2000 U.S. Department of Energy Assistant Secretary, Energy Efficiency & Renewable Energy Office of Building Research and Standards Washington, DC 20585 EA-i ENVIRONMENTAL ASSESSMENT FOR RESIDENTIAL CENTRAL AIR CONDITIONERS AND HEAT PUMPS TABLE OF CONTENTS 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EA-1 2.0 PURPOSE AND NEED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EA-1 3.0 ALTERNATIVES INCLUDING THE PROPOSED ACTION . . . . . . . . . . . . . . . . . EA-2 3.1 No Action Alternative . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EA-2 3.2 Proposed Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EA-3 3.3 Alternative Standards

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Preliminary design package for residential heating/cooling system--Rankine air conditioner redesign  

DOE Green Energy (OSTI)

This report contains a summary of the preliminary redesign and development of a marketable single-family heating and cooling system. The objectives discussed are the interim design and schedule status of the Residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.

Not Available

1978-12-01T23:59:59.000Z

42

Finding of No Significant Impact for Energy Conservation Standards for Residential Central Air Conditioners and Heat Pumps (01/01)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

01 01 Federal Register / Vol. 66, No. 14 / Monday, January 22, 2001 / Notices DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy Finding of No Significant Impact Energy Conservation Program for Consumer Products AGENCY: Department of Energy. ACTION: Finding of No Significant Impact (FONSI) for Energy Conservation Standard for Residential Central Air Conditioners and Heat Pumps. SUMMARY: The Energy Policy and Conservation Act, as amended by the National Energy Conservation Policy Act and the National Appliance Energy Conservation Act, and the National Appliance Energy Conservation Amendments, prescribes energy conservation standards for certain major household appliances, and requires the Department of Energy (DOE) to administer an energy conservation program for these products. Based on an

43

Seasonal efficiencies of residential heat pump air conditioners with inverter-driven compressors  

SciTech Connect

This paper describes a study to experimentally determine the steady-state characteristics, cyclic effect, and frosting/defrosting effect of a inverter heat pump currently available on the Japanese market and compute its seasonal efficiency based on the local outdoor air temperature data. It has been found that the APF of this heat pump is higher by 15% than that of the conventional fixed-speed heat pump. If cyclic and frosting/defrosting losses are eliminated, the APF of the inverter heat pump will be further improved by 2% to 6%. For the evaluation of an inverter heat pump, APF alone is not sufficient, and an additional parameter such as an annual comfort factor (ACF) is needed.

Hori, M.; Akamine, I.; Sakai, T.

1985-01-01T23:59:59.000Z

44

Electrolux Gibson Air Conditioner and Equator Clothes Washer...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing...

45

The Beeping Air Conditioner : EnergySmart School Inventors  

NLE Websites -- All DOE Office Websites (Extended Search)

The Beeping Air Conditioner icon. The Beeping Air Conditioner Work in Progress Sketches Team Picture Miniature Hydroelectric Power Plant icon The Plugger icon. The Light Searcher...

46

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

you need to mount the air conditioner at the narrow end of a long room, then look for a fan control known as "Power Thrust" or "Super Thrust" that sends the cooled air farther...

47

List of Central Air conditioners Incentives | Open Energy Information  

Open Energy Info (EERE)

Central Air conditioners Incentives Central Air conditioners Incentives Jump to: navigation, search The following contains the list of 1032 Central Air conditioners Incentives. CSV (rows 1-500) CSV (rows 501-1000) CSV (rows 1001-1032) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP (Central and North) - CitySmart Program (Texas) Utility Rebate Program Texas Commercial Industrial Institutional Local Government Schools Boilers Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Furnaces Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Roofs Windows Yes AEP (Central and SWEPCO) - Coolsaver A/C Tune Up (Texas) Utility Rebate Program Texas Commercial Installer/Contractor

48

Ductless Mini-Split Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners August 9, 2012 - 4:05pm Addthis A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of テつゥiStockphoto/LUke1138. A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ツゥiStockphoto/LUke1138. What does this mean for me? A ductless mini-split air conditioner is easier to install than a central air conditioning system. A ductless mini-split air conditioner provides zoned air conditioning without ducting. A ductless mini-split air conditioner is relatively easy to install and does not provide an entry point for intruders as some room air conditioners do. Ductless, mini split-system air-conditioners (mini splits) have numerous

49

Ductless Mini-Split Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners August 9, 2012 - 4:05pm Addthis A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of テつゥiStockphoto/LUke1138. A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ツゥiStockphoto/LUke1138. What does this mean for me? A ductless mini-split air conditioner is easier to install than a central air conditioning system. A ductless mini-split air conditioner provides zoned air conditioning without ducting. A ductless mini-split air conditioner is relatively easy to install and does not provide an entry point for intruders as some room air conditioners do. Ductless, mini split-system air-conditioners (mini splits) have numerous

50

Building Technologies Office: Energy-Efficient Window Air Conditioner  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy-Efficient Window Energy-Efficient Window Air Conditioner Ratings Research Project to someone by E-mail Share Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Facebook Tweet about Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Twitter Bookmark Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Google Bookmark Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Delicious Rank Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Digg Find More places to share Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on

51

DOE Investigates Possible Air Conditioner Efficiency Violations |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Investigates Possible Air Conditioner Efficiency Violations Investigates Possible Air Conditioner Efficiency Violations DOE Investigates Possible Air Conditioner Efficiency Violations February 15, 2012 - 5:13pm Addthis The Department of Energy's Office of Enforcement is committed to its compliance enforcement responsibilities with regard to federal energy conservation standards and ensuring that all those subject to the requirements are treated fairly and equally. Today, the Office of Enforcement issued a series of subpoenas as part of an investigation to determine whether manufacturers of split-system air conditioners are making and distributing in the U.S. condensing units that do not meet the current 13 SEER (Seasonal Energy Efficiency Ratio) federal energy conservation standard, which has been the standard since 2006.

52

An Investigation of Alternative Methods for Measuring Static Pressure of Unitary Air Conditioners and Heat Pumps  

E-Print Network (OSTI)

This project was created to address an important issue currently faced by test facilities measuring static pressure for air-conditioning and heat pumps. Specifically, ASHRAE Standard 37, the industry standard for test setup, requires an outlet duct of a certain length, based on the unit outlet geometry, and this ducting added to the unit height may result in a test apparatus height that exceeds psychometric test room dimensions. This project attempted to alter the outlet duct in a way that reduces the test apparatus height while maintaining the reliability of the ASHRAE Standard 37 testing setup. The investigation was done in two scenarios, the first, which altered the direction of the flow after the unit with an elbow and measured static pressure downstream of the elbow, and the second which inserted a passive resistive piece in the flow to decrease the required distance between the unit and the static pressure measurement. Three air handling units were used in Scenario 1 and Scenario 2 testing, with the two smallest units additionally being tested in Scenario 1 with an over-sized duct. The scenario tests were required to be within 5% power and 2.5% airflow of a baseline test following ASHRAE Standard 37. he results for Scenario 1 have shown that ASHRAE Standard 37 can be modified to reduce testing height restrictions by using a square elbow with turning vanes, provided it is oriented in a specific way in relation to the blower. Furthermore, additional Scenario 1 testing on the over-sized outlet duct shows that possibilities exist for using a single over-sized duct to successfully meet ASHRAE Standard 37 testing conditions when testing a variety of units. Finally, the results of Scenario 2 have shown that the height constraints of the outlet duct can be reduced by installing a passive resistive device consisting of a mesh at the outlet; however, this approach applies only to those units with the heat exchanger located downstream of the blower. As a result of specific issues or problems that were encountered during the project that were beyond the scope, eleven case studies were presented and recommended for future work.

Wheeler, Grant Benson

2013-08-01T23:59:59.000Z

53

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

will result in rising sales prices. VRF Air Conditioner Themain users of VRF air conditioners are commercial usersand large-scale households, and VRF air conditioners usually

Zhou, Nan

2010-01-01T23:59:59.000Z

54

Variable Refrigerant Flow Air Conditioners and Heat Pumps for Commercial Buildings  

Science Conference Proceedings (OSTI)

Multi-split heat pumps have evolved from a technology suitable for residential and light commercial buildings to variable refrigerant flow (VRF) systems that can provide efficient space conditioning for large commercial buildings. VRF systems are enhanced versions of ductless multi-split systems, permitting more indoor units to be connected to each outdoor unit and providing additional features such as simultaneous heating and cooling and heat recovery. VRF systems are very popular in Asia and Europe and...

2008-01-25T23:59:59.000Z

55

Monitoring and evaluation of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached houses in Austin, Texas  

SciTech Connect

The US DOE initiated this project to evaluate the performance of an air conditioner retrofit program in Austin, Texas. The City's Austin's Resource Management Department pursued this project to quantify the retrofit effect of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached homes. If successfully implemented, this retrofit program could help defer construction of a new power plant which is a major goal of this department. The project compares data collected from 12 houses during two cooling seasons under pre-retrofit and then post-retrofit air conditioner units. The existing low-efficiency air conditioners were monitored during the 1987 cooling season, replaced during the 1987--88 heating season with new, smaller sized, high-efficiency units, and then monitored again during the 1988 cooling season. Results indicated that the air conditioner retrofits reduce the annual air conditioner electric consumption and peak electric demand by an average of 38%. When normalized to the nominal capacity of the air conditioner, average demand savings were 1.12 W/ft{sup 2} and estimated annual energy savings were 1.419 kWh/ft{sup 2}. Individual air conditioner power requirements were found to be a well defined function of outdoor temperature as expected. In the absence of detailed data, estimates of the peak demand reductions of new air conditioners can be made from the manufacturer's specifications. Air conditioner energy consumption proved to be strongly linear as a function of the outdoor temperature as expected when taken as an aggregate. No noticeable differences in the diversity factor of the air conditioner usage were found. Analysis of the retrofit effect using PRISM yields estimates of the reduction in normalized annual consumption (NAC) and annual cooling consumption of 12% and 30%. 2 refs., 11 figs., 17 tabs.

Burns, R.; Hough, R.E. (Fleming (W.S.) and Associates, Inc., Syracuse, NY (United States))

1991-10-01T23:59:59.000Z

56

Evaluation of Energy-Efficiency Standards for Room Air Conditioners...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy-Efficiency Standards for Room Air Conditioners in the US Title Evaluation of Energy-Efficiency Standards for Room Air Conditioners in the US Publication Type Journal Article...

57

The Impact of Energy Recovery on Window Air-conditioner Efficiency  

E-Print Network (OSTI)

An experimental energy recovering air-conditioner can produce fresh air exchange heat with exhaust air in the heat exchanger, which has no additional moving parts. The EER of the experimental air-conditioner (EAC) is increased by 17.4~37.3 percent over that of an ordinary window type air-conditioner (OAC), which is very significant for energy efficiency. On the other hand, the fresh air proportion of the EAC is increased by ~20 percent over that of the OAC, and the indoor noise of the EAC is decreased by ~3.8 dB. Therefore, indoor environment quality can be greatly improved with the EAC.

Luo, Q.; Tang, C.; Liao, K.

2006-01-01T23:59:59.000Z

58

Product Standards for Air Conditioners (Japan) | Open Energy Information  

Open Energy Info (EERE)

Air Conditioners (Japan) Air Conditioners (Japan) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Product Standards for Air Conditioners (Japan) Focus Area: Appliances & Equipment Topics: Policy Impacts Website: www.eccj.or.jp/top_runner/pdf/tr_air_conditioners_apr.2008.pdf Equivalent URI: cleanenergysolutions.org/content/product-standards-air-conditioners-ja Language: English Policies: "Deployment Programs,Regulations" is not in the list of possible values (Deployment Programs, Financial Incentives, Regulations) for this property. DeploymentPrograms: Industry Codes & Standards Regulations: Appliance & Equipment Standards and Required Labeling This Energy Conservation Center Japan (ECCJ) document was created as a guide in response to its newly established set of standards and labelling

59

Effect of refrigerant charge, duct leakage, and evaporator air flow on the high temerature performance of air conditioners and heat pumps  

E-Print Network (OSTI)

An experimental study was conducted to quantify the effect of several installation items on the high outdoor ambient temperature performance of air conditioners. These installation items were: improper amount of refrigerant charge, reduced evaporator airflow, and return air leakage from hot attic spaces. There were five sets of tests used for this research: two of them for the charging tests, two for the reduced evaporator airflow, and one for the return air leakage tests. For the charging tests, the indoor room conditions were 80'F (27.8'C) dry-bulb and 50% relative humidity. The outdoor conditions ranged from 95'F (350C) all the way up to 120'F (48.9'C). Charge levels ranged from 30% undercharged to 40% overcharged for the short-tube orifice unit. For the thermal expansion valve (TXV) unit, charge levels ranged from-36% charging to +27% charging. Performance was quantified with the following variables: total capacity, energy efficiency ratio (EER), and power. The performance of the orifice unit was more sensitive to charge than it was for the TXV unit. For the TXV unit on the -27% to +27% charging range, the capacity and EER changed little with charge. A TXV unit and a short-tube orifice unit were also tested for reduced evaporator airflow. As evaporator airflow decreased, the capacity and EER both decreased as expected. However, the drop was not as significant as with the charging tests. For the extreme case of 50% reduced evaporator airflow, neither unit's capacity or EER dropped more than 25%. Return air leakage from hot attic spaces was simulated by assuming adiabatic mixing of the indoor air at normal conditions with the attic air at high temperatures. Effective capacity and EER both decreased with increased return air leakage. However, power consumption was relatively constant for all variables except outdoor temperature, which meant that for the same power consumption, the unit delivered much lower performance when there was return air leakage. The increase in sensible heat ratio (SHR) with increasing leakage showed perhaps the most detrimental effect of return air leakage on performance, which was the inability of the unit to absorb moisture from the environment.

Rodriguez, Angel Gerardo

1995-01-01T23:59:59.000Z

60

Effect of Refrigerant Charge, Duct Leakage, and Evaporator Air Flow on the High Temperature Performance of Air Conditioners and Heat Pumps  

E-Print Network (OSTI)

An experimental study was conducted to quantify the effect of several installation items on the high outdoor ambient temperature performance of air conditioners. These installation items were: improper amount of refrigerant charge, reduced evaporator airflow, and return air leakage from hot attic spaces. There were five sets of tests used for this research: two of them for the charging tests, two for the reduced evaporator airflow, and one for the return air leakage tests. For the charging tests, the indoor room conditions were 80ーF (27.8ーC) dry-bulb and 50% relative humidity. The outdoor conditions ranged from 95ーF (35ーC) all the way up to 120ーF (48.9ーC). Charge levels ranged from 30% undercharged to 40% overcharged for the short-tube orifice unit. For the thermal expansion valve (TXV) unit, charge levels ranged from -36% charging to +27% charging. Performance was quantified with the following variables: total capacity, energy efficiency ratio (EER), and power. The performance of the orifice unit was more sensitive to charge than it was for the TXV unit. For the TXV unit on the -27% to +27% charging range, the capacity and EER changed little with charge. A TXV unit and a short-tube orifice unit were also tested for reduced evaporator airflow. As evaporator airflow decreased, the capacity and EER both decreased as expected. However, the drop was not as significant as with the charging tests. For the extreme case of 50% reduced evaporator airflow, neither unit's capacity or EER dropped more than 25%. Return air leakage from hot attic spaces was simulated by assuming adiabatic mixing of the indoor air at normal conditions with the attic air at high temperatures. Effective capacity and EER both decreased with increased return air leakage. However, power consumption was relatively constant for all variables except outdoor temperature, which meant that for the same power consumption, the unit delivered much lower performance when there was return air leakage. The increase in sensible heat ratio (SHR) with increasing leakage showed perhaps the most detrimental effect of return air leakage on performance, which was the inability of the unit to absorb moisture from the environment.

Rodriguez, Angel Gerardo

2007-11-29T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Candidate chemical systems for air cooled, solar powered, absorption air conditioner design. Part II. Solid absorbents, high latent heat refrigerants  

DOE Green Energy (OSTI)

Work done in attempting to qualify absorption refrigeration systems based on refrigerants with intermediate latent heats of vaporization is summarized. In practice, these comprise methanol, ammonia, and methylamine. A wide variety of organic substances, salts, and mixtures were evaluated in as systematic a manner as possible. Several systems of interest are described. The system, LiClO/sub 3/--LiBr--H/sub 2/O, is a good back up system to our first choice of an antifreeze additive system, and thermodynamically promising but subject to some inconvenient materials limitations. The system, LiBr/ZnBr/sub 2/--methanol, is thermodynamically promising but requires additional kinetic qualification. Chemical stability of the system, LiCNS--ammonia/methylamine with various other third components, does not appear to be adequate for a long-lived system.

Biermann, W. J.

1978-04-01T23:59:59.000Z

62

Air Conditioner Compressor Performance Model  

SciTech Connect

During the past three years, the Western Electricity Coordinating Council (WECC) Load Modeling Task Force (LMTF) has led the effort to develop the new modeling approach. As part of this effort, the Bonneville Power Administration (BPA), Southern California Edison (SCE), and Electric Power Research Institute (EPRI) Solutions tested 27 residential air-conditioning units to assess their response to delayed voltage recovery transients. After completing these tests, different modeling approaches were proposed, among them a performance modeling approach that proved to be one of the three favored for its simplicity and ability to recreate different SVR events satisfactorily. Funded by the California Energy Commission (CEC) under its load modeling project, researchers at Pacific Northwest National Laboratory (PNNL) led the follow-on task to analyze the motor testing data to derive the parameters needed to develop a performance models for the single-phase air-conditioning (SPAC) unit. To derive the performance model, PNNL researchers first used the motor voltage and frequency ramping test data to obtain the real (P) and reactive (Q) power versus voltage (V) and frequency (f) curves. Then, curve fitting was used to develop the P-V, Q-V, P-f, and Q-f relationships for motor running and stalling states. The resulting performance model ignores the dynamic response of the air-conditioning motor. Because the inertia of the air-conditioning motor is very small (H<0.05), the motor reaches from one steady state to another in a few cycles. So, the performance model is a fair representation of the motor behaviors in both running and stalling states.

Lu, Ning; Xie, YuLong; Huang, Zhenyu

2008-09-05T23:59:59.000Z

63

Covered Product Category: Residential Central Air Conditioners | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Central Air Conditioners Central Air Conditioners Covered Product Category: Residential Central Air Conditioners October 7, 2013 - 10:38am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including residential central air conditioners (CACs), which are an ENERGY STARツョ-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases

64

Rating of Mixed Split Residential Air Conditioners  

E-Print Network (OSTI)

A methodology is presented for rating the performance of mixed, split residential air conditioners. The method accounts for the impact on system performance of the indoor evaporator, expansion device and fan; three major components that are likely to be substituted for the matched components in a mixed system. The method allows calculation of capacity at 95ーF rating point and seasonal energy efficiency ratio, SEER, without performing laboratory test of the complete system. Limitations of the procedure, present work, and anticipated improvements are also discussed.

Domanski, P. A.

1988-01-01T23:59:59.000Z

65

Building Energy Software Tools Directory: Room Air Conditioner Cost  

NLE Websites -- All DOE Office Websites (Extended Search)

Room Air Conditioner Cost Estimator Room Air Conditioner Cost Estimator Screen capture of Room Air Conditioner Cost Estimator The cost estimator compares high-efficiency room air conditioners to standard equipment in terms of life cycle cost. It provides an alternative to complicated building simulation models, while offering more precision than simplified estimating tools that are commonly available. The cost estimator assists decision-making regarding the purchase or replacement of room air conditioning equipment, by estimating a productソスs lifetime energy cost savings at various efficiency levels. Screen Shots Keywords air conditioner, life-cycle cost, energy performance, residential buildings, energy savings Validation/Testing Internal reviews at Pacific Northwest National Laboratory.

66

Measuring Short-term Air Conditioner Demand Reductions for  

E-Print Network (OSTI)

allow users to look up the demand reduction per device based on the daily maximum temperatureLBNL-5330E Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement-term Air Conditioner Demand Reductions for Operations and Settlement Josh Bode, Michael J. Sullivan Freeman

67

Study on Water-Cooled Solar Semiconductor Air Conditioner  

Science Conference Proceedings (OSTI)

Water-cooled solar semiconductor air conditioner was designed. Relevant calculation was made to determine the room's cooling load, which export the solar panels and battery capacity, followed by selection of CNC matcher. Development work also involves ... Keywords: solar energy, peltier effect, semiconductor air conditioner

Dong Zhi-Ming; Chang Ji-Bin; Xiang Li-Juan; Zhou Xue-Bin

2012-04-01T23:59:59.000Z

68

The effects of galvanic corrosion on air conditioner performance  

E-Print Network (OSTI)

Corrosion of air conditioner outdoor heat exchangers (condensers) poses a significant problem for consumers living in coastal regions. This research sought to experimentally determine effects of galvanic corrosion on air conditioner condenser coils when subjected to high salt environments such as those found along the Gulf coast of the southern United States. The particular coil configuration investigated was comprised of copper tubing and aluminum fins, which form a galvanic couple in the presence of an electrolyte (salt water). Corrosion at the tube/fin junction results in a decrease of contact area through which heat is transferred. As a result, degradation of air conditioner performance occurs. An experimental plan was developed to operate two air conditioners for a period of approximately one year at a testing site in Galveston, Texas. Psychrometric evaluation of these units was conducted prior to exposure, at the midpoint of exposure, and at the conclusion of exposure. In addition, samples of copper and aluminum coils and coupons were subjected to the same coastal environment and investigated for corrosion attack. An accelerated corrosion test was also conducted to determine the effects of increased temperature, relative humidity, and salt concentrations on these samples. Air conditioner performance was measured during steady state cooling tests at outdoor conditions of 75?F (23.9?C), 82?F (27.8?C), 95?F (35.0?C), and 105?F (40.6?C) with an indoor temperature of 80?F (26.7?C) dry-bulb and 67?F (19.4?C) wet-bulb. Results of this testing showed that both units demonstrated average decreases in both cooling capacity and system EER. Sensible and latent capacity degradation for both package units showed decreases of approximately 4.6% and 20.9% respectively. System EER dropped over the course of the field investigation by 11.5% for one of the units and 8.3% for the other. An average corrosion rate for sample coupons subjected to the Galveston environment was calculated to be 0.13 MPY. Microscopic evaluation of aluminum from these galvanic couples after approximately one year of exposure showed an average pit depth approximately 19% of the aluminum thickness at the material interface. In comparison, aluminum fin collars at the material interface had an average pit about 22% of the thickness. Accelerated corrosion testing revealed some pitting, but not to the extent exhibited by field samples. A detailed description of the experimental setup, procedure, and results are provided.

Grisham, Phillip Ryan

2001-01-01T23:59:59.000Z

69

ENERGY STAR Qualified Room Air Conditioners | Data.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Room Air Conditioners Room Air Conditioners Consumer Data Apps Challenges Resources About Blogs Let's Talk Feedback Consumer You are here Data.gov ツサ Communities ツサ Consumer ツサ Data ENERGY STAR Qualified Room Air Conditioners Dataset Summary Description Room Air Conditioners that have earned the ENERGY STAR are more efficient than standard models. ENERGY STAR is the trusted symbol for energy efficiency helping consumers save money and protect the environment through energy-efficient products and practices. More information on ENERGY STAR is available at www.energystar.gov. Tags {"Room Air Conditioners","Energy Star",products,"energy efficiency",efficient,"greenhouse gas emissions",climate,utility,utilities,household,savings,labels,partners,certification}

70

Four Central Air Conditioners Determined Noncompliant With Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Four Central Air Conditioners Determined Noncompliant With Energy Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard October 3, 2011 - 9:21am Addthis The U.S. Department of Energy's Office of Enforcement issued a Notice of Noncompliance Determination (Notice) on September 27, 2011, to AeroSys, Inc. (AeroSys) regarding four models of central (through-the-wall) air conditioners that fail to meet Federal energy efficiency requirements. DOE tests revealed that AeroSys through-the-wall air conditioner models THDC-18S, THDC-18T, THDC-24S, and THDC-24T do not meet the minimum energy efficiency requirements set forth in DOE regulations. The Notice provides that AeroSys must inform those to whom it has sold the models that they do

71

Commercial Central Air Conditioners, Purchasing Specifications for Energy-Efficient Products (Fact Sheet)  

Science Conference Proceedings (OSTI)

Energy efficiency purchasing specifications for federal procurements of commercial central air conditioners.

Not Available

2011-02-01T23:59:59.000Z

72

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and  

NLE Websites -- All DOE Office Websites (Extended Search)

Orders AeroSys to Halt Distribution of Inefficient Air Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models March 30, 2010 - 10:05am Addthis Today, the Department of Energy announced that it is requiring AeroSys, Inc. to stop distributing two product models - one air conditioner and one heat pump - that DOE testing found to consume more energy than allowed under federal efficiency standards. This is the latest step in the Department's investigation into whether AeroSys has been selling products in the U.S. that violate minimum appliance efficiency standards. This is the first time that the Department of Energy has told a company or manufacturer that it must halt the distribution of products that fail to

73

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Orders AeroSys to Halt Distribution of Inefficient Air Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models March 30, 2010 - 10:05am Addthis Today, the Department of Energy announced that it is requiring AeroSys, Inc. to stop distributing two product models - one air conditioner and one heat pump - that DOE testing found to consume more energy than allowed under federal efficiency standards. This is the latest step in the Department's investigation into whether AeroSys has been selling products in the U.S. that violate minimum appliance efficiency standards. This is the first time that the Department of Energy has told a company or manufacturer that it must halt the distribution of products that fail to

74

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Orders AeroSys to Halt Distribution of Inefficient Air Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards March 30, 2010 - 12:00am Addthis WASHINGTON, DC - Today, the Department of Energy announced that it is requiring AeroSys, Inc. to stop distributing two product models - one air conditioner and one heat pump - that DOE testing found to consume more energy than allowed under federal efficiency standards. This is the latest step in the Department's investigation into whether AeroSys has been selling products in the U.S. that violate minimum appliance efficiency standards. This is the first time that the Department of Energy has told a

75

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing October 6, 2010 - 10:08am Addthis DOE testing in support of the ENERGY STAR program has revealed that an Electrolux Gibson air conditioner (model GAH105Q2T1) and an Equator clothes washer (model EZ 3720 CEE), both of which claimed ENERGY STAR ratings, do not meet the ENERGY STAR requirements. Specifically, the test results for the Electrolux Gibson model show that, when tested in accordance with DOE's test procedures, it consumed 6.1 percent more energy than the Energy Star requirement. Test results for the Equator model show that it exceeds Energy Star's water factor requirements by 12.3 percent.

76

Covered Product Category: Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Room Air Conditioners Room Air Conditioners Covered Product Category: Room Air Conditioners October 7, 2013 - 10:40am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including room air conditioners, which are an ENERGY STARツョ-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

77

Covered Product Category: Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Room Air Conditioners Room Air Conditioners Covered Product Category: Room Air Conditioners October 7, 2013 - 10:40am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including room air conditioners, which are an ENERGY STARツョ-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

78

Variable Speed Fan Retrofits for Computer Room Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

Variable-Speed Fan Retrofits for Computer-Room Air Conditioners Prepared for the U.S. Department of Energy Federal Energy Management Program Technology Case Study Bulletin By...

79

Five ENERGY STAR Room Air Conditioners Fail Testing  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy's Office of Enforcement announced today that DOE testing has identified five Friedrich room air conditioners that do not meet the ENERGY STAR Program痴 energy...

80

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing October 6, 2010 - 10:08am Addthis DOE testing in support of the ENERGY STAR program has revealed that an Electrolux Gibson air conditioner (model GAH105Q2T1) and an Equator clothes washer (model EZ 3720 CEE), both of which claimed ENERGY STAR ratings, do not meet the ENERGY STAR requirements. Specifically, the test results for the Electrolux Gibson model show that, when tested in accordance with DOE's test procedures, it consumed 6.1 percent more energy than the Energy Star requirement. Test results for the Equator model show that it exceeds Energy Star's water factor requirements by 12.3 percent.

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Building America Top Innovations 2013 Profile ツ High-Efficiency Window Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

an inexpensive, portable form of spot cooling, an inexpensive, portable form of spot cooling, making them a good solution for supplemental cooling, for air conditioning in homes that lack ductwork, and for renters. As a result, 7.5 million window air conditioners are purchased each year in the United States-more than all other home cooling equipment combined. However, window air conditioners have low minimum efficiency standards, and their installation typically results in air leakage, which significantly reduces the equipment's performance. To measure the impact these products have on home energy use, researchers at the National Renewable Energy Laboratory (NREL) studied the performance of one 10-year-old and three new window air conditioners in a range of climates and conditions at NREL's Advanced Heating, Ventilation, and

82

Adsorption air conditioner for electric vehicle applications. Revision 1  

DOE Green Energy (OSTI)

This paper shows an analysis of the applicability of an adsorption system for electric vehicle (EV) air conditioning. Adsorption systems are designed and optimized to provide the required cooling for four combinations of vehicle characteristics and driving cycles. The resulting adsorption systems are compared with vapor compression air conditioners that can satisfy the cooling load. The objective function is the overall system weight, which includes the cooling system weight and the weight of the battery necessary to provide energy for air conditioner operation. The system with the minimum overall weight is considered to be the best, because a lower weight results in an increased vehicle range. The results indicate that, for the conditions analyzed in this paper, vapor compression air conditioners are superior to adsorption systems not only because they are lighter, but also because they have a higher COP and are more compact.

Aceves, S.M.

1994-07-27T23:59:59.000Z

83

Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners Title Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners Publication Type Conference Proceedings Year of Publication 2000 Authors Shugars, John, Philip Coleman, Christopher T. Payne, and Laura Van Wie McGrory Conference Name Proceedings from the 2000 ACEEE Summer Study on Energy Efficiency in Buildings Volume 10 Pagination 217-226 Date Published 01/2000 Abstract The energy efficiency ofmany products has increased markedly over the past decade. A conspicuous exception to this trend is commercialpackaged rooftop air conditioners, which have experiencedlittle to no efficiency improvement since 1992 when the Energy Policy Act of 1992 imposed federal minimum standards. Packaged rooftop units have been estimated to use on the order of76 billion kWh annually in the US, at a cost ofroughly $5.6 billion. Sales of these units are growing, and the majority of units sold have energy efficiency ratios (EERs) at orjust above the current national minimum efficiency standards. In this paper we document the static efficiencies ofcommercialpackaged air conditioners, explore the reasons behindthis efficiency gap, and assess opportunities for overcoming the barriers to efficiency improvements in these products.

84

Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates  

E-Print Network (OSTI)

An experimental study was conducted to quantify the effect of return air leakage from hot/humid attic spaces on the performance of a residential air conditioner. Tests were conducted in psychrometric facilities where temperatures and humidities could be controlled closely. Return air leakage from hot attic spaces was simulated by assuming adiabatic mixing of the indoor air at normal conditions with the attic air at high temperatures. Effective capacity and Energy Efficiency Ratio both decreased with increased return air leakage. However, power consumption was relatively constant for all variables except outdoor temperature, which meant that for the same power consumption, the unit delivered much lower performance when there was return air leakage. The increase in sensible heat ratio (SHR) with increasing leakage showed one of the most detrimental effects of return air leakage on performance.

O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

1996-01-01T23:59:59.000Z

85

Rooftop Unitary Air Conditioner with Integral Dedicated Outdoor Air System  

SciTech Connect

Energy use of rooftop and other unitary air-conditioners in commercial applications accounts for about 1 quad (10{sup 15} Btu) of primary energy use annually in the U.S. [Reference 7]. The realization that this cooling equipment accounts for the majority of commercial building cooled floorspace and the majority also of commercial building energy use has spurred development of improved-efficiency equipment as well as development of stricter standards addressing efficiency levels. Another key market driver affecting design of rooftop air-conditioning equipment has been concern regarding comfort and the control of humidity. Trends for increases in outdoor air ventilation rates in certain applications, and the increasing concern about indoor air quality problems associated with humidity levels and moisture in buildings points to a need for improved dehumidification capability in air-conditioning equipment of all types. In many cases addressing this issue exacerbates energy efficiency, and vice versa. The integrated dedicated outdoor air system configuration developed in this project addresses both energy and comfort/humidity issues.

Tiax Llc

2006-02-28T23:59:59.000Z

86

APPROVED ICE STORAGE AIR CONDITIONERS Revised as of 06-18-2008  

E-Print Network (OSTI)

APPROVED ICE STORAGE AIR CONDITIONERS Revised as of 06-18-2008 The following vendors and their ice storage air conditioners models can be used in the ice storage air conditioner compliance option. Input details are listed below for the approved equipment. Manufacturer Ice Energy, Inc 9351 Eastman Park Drive

87

Laboratory Performance Testing of Residential Window Air Conditioners  

SciTech Connect

Window air conditioners are the dominant cooling product for residences, in terms of annual unit sales. They are inexpensive, portable and can be installed by the owner. For this reason, they are an attractive solution for supplemental cooling, for retrofitting air conditioning into a home which lacks ductwork, and for renters. Window air conditioners for sale in the United States are required to meet very modest minimum efficiency standards. Four window air conditioners' performance were tested in the Advanced HVAC Systems Laboratory on NREL's campus in Golden, CO. In order to separate and study the refrigerant system's performance, the unit's internal leakage pathways, the unit's fanforced ventilation, and the leakage around the unit resulting from installation in a window, a series of tests were devised that focused on each aspect of the unit's performance. These tests were designed to develop a detailed performance map to determine whole-house performance in different climates. Even though the test regimen deviated thoroughly from the industry-standard ratings test, the results permit simple calculation of an estimated rating for both capacity and efficiency that would result from a standard ratings test. Using this calculation method, it was found that the three new air conditioners' measured performance was consistent with their ratings. This method also permits calculation of equivalent SEER for the test articles. Performance datasets were developed across a broad range of indoor and outdoor operating conditions, and used them to generate performance maps.

Winkler, J.; Booten, C.; Christensen, D.; Tomerlin, J.

2013-03-01T23:59:59.000Z

88

Development of vehicle magnetic air conditioner (VMAC) technology. Final report  

SciTech Connect

The objective of Phase I was to explore the feasibility of the development of a new solid state refrigeration technology - magnetic refrigeration - in order to reduce power consumption of a vehicle air conditioner by 30%. The feasibility study was performed at Iowa State University (ISU) together with Astronautics Corporation of America Technology Center (ACATC), Madison, WI, through a subcontract with ISU.

Gschneidner, Karl A., Jr.; Pecharsky, V.K.; Jiles, David; Zimm, Carl B.

2001-08-28T23:59:59.000Z

89

HEATING, AIR-CONDITIONING AND REFRIGERATION DISTRIBUTORS INTERNATIONAL (HARDI)  

Energy.gov (U.S. Department of Energy (DOE))

OE Framework Document and Stakeholder Meeting regarding the Enforcement of the updated Energy Conservation Standards for Air Conditioners, Furnaces and Heat Pumps.

90

Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

Bridging Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners John Shugars, Consultant Philip Coleman, Lawrence BerkeleyNational Laboratory ChristopherPayne, Lawrence Berkeley National Laboratory Laura Van Wie McGrory, Lawrence Berkeley National Laboratory ABSTRACT The energy efficiency ofmany products has increased markedly over the past decade. A conspicuous exception to this trend is commercial packaged rooftop air conditioners, which have experiencedlittle to no efficiency improvement since 1992 when the Energy Policy Act of 1992 imposed federal minimum standards. Packaged rooftop units have been estimated to use on the order of76 billion kWh annually in the US, at a cost ofroughly $5.6 billion. Sales of these units are growing, and the majority of units sold have energy efficiency ratios (EERs) at orjust above the current national minimum efficiency

91

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology  

SciTech Connect

The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

Not Available

1993-11-01T23:59:59.000Z

92

Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype  

SciTech Connect

This report documents the design of a desiccant enhanced evaporative air conditioner (DEVAP AC) prototype and the testing to prove its performance. Previous numerical modeling and building energy simulations indicate a DEVAP AC can save significant energy compared to a conventional vapor compression AC (Kozubal et al. 2011). The purposes of this research were to build DEVAP prototypes, test them to validate the numerical model, and identify potential commercialization barriers.

Kozubal, E.; Woods, J.; Judkoff, R.

2012-04-01T23:59:59.000Z

93

Determining benefits and costs of improved central air conditioner efficiencies  

SciTech Connect

Economic impacts on individual consumers from possible revisions to U.S. residential-type central air conditioner energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a central air conditioner and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers due to modest increases in efficiency are significant. For an efficiency increase of 20percent over the existing minimum standard (i.e., 12 SEER), 35percent of households with central air conditioners experience significant LCC savings, with an average savings of $453, while 25percent show significant LCC losses, with an average loss of $158 compared to apre-standard LCC average of $5,170. The remainder of the population (40percent) are largely unaffected.

Rosenquist, G.; Levok, A.; Chan, P.; McMahon, J.

2001-01-12T23:59:59.000Z

94

Determining benefits and costs of improved central air conditioner efficiencies  

SciTech Connect

Economic impacts on individual consumers from possible revisions to U.S. residential-type central air conditioner energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a central air conditioner and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers due to modest increases in efficiency are significant. For an efficiency increase of 20percent over the existing minimum standard (i.e., 12 SEER), 35percent of households with central air conditioners experience significant LCC savings, with an average savings of $453, while 25percent show significant LCC losses, with an average loss of $158 compared to apre-standard LCC average of $5,170. The remainder of the population (40percent) are largely unaffected.

Rosenquist, G.; Levok, A.; Chan, P.; McMahon, J.

2001-01-12T23:59:59.000Z

95

Air Conditioner "Evolves" in Novel NIST Study  

Science Conference Proceedings (OSTI)

... A new NIST tool combining principles of engineering with those of natural evolution yielded the design for a more energy-efficient roof-top air ...

2013-09-03T23:59:59.000Z

96

Energy Consumption Estimation for Room Air-conditioners Using Room Temperature Simulation with One-Minute Intervals  

E-Print Network (OSTI)

For the purpose of developing optimized control algorithm for room air-conditioners to ensure their energy efficiency, a short time interval (i.e., one minute) simulation of building thermal performance is necessary because the sampling time interval for room air-conditioner control is one minute in general. This paper studies the short-time interval room air temperature simulation method using the response factor method. Using the simulated room air temperature, an air-conditioner's running time can be known so that its energy consumption can be estimated accurately. In order to verify the simulation accuracy, an actual room equipped with a gas-engine heat pump (GHP) air-conditioning system is studied by both simulation and measurement. The cooling amount produced by the GHP is calculated using measured refrigerant pressure and temperature at condenser and evaporator respectively. The Root Mean Square Error (RMSE) between measured cooling amount and simulated cooling load is 18.9 percent of the average measured value. The profile of simulated room air temperature in both air-conditioned daytime and nighttime without air-conditioning can match the measured room air temperature. With respect to the estimated energy consumption, the profile of simulated energy consumption can match the measured data. The simulation accuracy of room air temperature and energy consumption during the air-conditioner start-up period is not good and needs to be improved in future research. But in general, the verification shows that this energy consumption simulation method is acceptable for evaluating the energy performance of a room air-conditioner, and can also be a useful tool for commissioning room air-conditioners.

Wang, F.; Yoshida, H.; Matsumoto, K.

2006-01-01T23:59:59.000Z

97

DOE Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Takes Action to Stop the Sales of Air-Con Air Conditioner Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown to Violate Federal Energy Efficiency Appliance Standards DOE Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown to Violate Federal Energy Efficiency Appliance Standards September 23, 2010 - 12:00am Addthis Washington, DC - The Department of Energy announced today that it has taken action against Air-Con, International, requiring the company to stop selling certain air conditioning systems in the U.S. that have been shown to violate minimum energy efficiency appliance standards. DOE is proposing a civil penalty of more than $230,000 for importing and distributing these inefficient cooling products. This action and the proposed penalties are part of the Department's continued commitment to act aggressively to remove

98

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy Efficiency Standard YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy Efficiency Standard October 11, 2012 - 4:10pm Addthis The U.S. Department of Energy's Office of Enforcement issued a Notice of Noncompliance Determination (Notice) on October 11, 2012, to YMGI Group, LLC (YMGI) regarding through-the-wall split system central air conditioner basic model TTWC-18K-31B. DOE enforcement testing revealed that this model operates at a Seasonal Energy Efficiency Rating (SEER) of 8.3. The current federal standard requires that through-the-wall split system central air conditioners operate at a SEER of 12 or greater. Addthis Related Articles Four Central Air Conditioners Determined Noncompliant With Energy

99

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy Efficiency Standard YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy Efficiency Standard October 11, 2012 - 4:10pm Addthis The U.S. Department of Energy's Office of Enforcement issued a Notice of Noncompliance Determination (Notice) on October 11, 2012, to YMGI Group, LLC (YMGI) regarding through-the-wall split system central air conditioner basic model TTWC-18K-31B. DOE enforcement testing revealed that this model operates at a Seasonal Energy Efficiency Rating (SEER) of 8.3. The current federal standard requires that through-the-wall split system central air conditioners operate at a SEER of 12 or greater. Addthis Related Articles Four Central Air Conditioners Determined Noncompliant With Energy

100

LBNL-54244 Life-cycle Cost and Payback Period Analysis for Commercial Unitary Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

44 44 Life-cycle Cost and Payback Period Analysis for Commercial Unitary Air Conditioners Greg Rosenquist, Katie Coughlin, Larry Dale, James McMahon, Steve Meyers Energy Analysis Department Environmental Energy Technologies Division Ernest Orlando Lawrence Berkeley National Laboratory University of California Berkeley, CA 94720 March 2004 This work was supported by the Office of Building Technologies of the U.S. Department of Energy, under Contract No. DE-AC03-76SF00098. ii iii ABSTRACT This report describes an analysis of the economic impacts of possible energy efficiency standards for commercial unitary air conditioners and heat pumps on individual customers in terms of two metrics: life-cycle cost (LCC) and payback period (PBP). For each of the two equipment classes considered, the 11.5 EER provides the largest mean LCC savings. The results

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Measured Impacts of Air Conditioner Condenser Shading  

E-Print Network (OSTI)

A study has been conducted by the Florida Solar Energy Center (FSEC) to examine if space cooling energy savings can be achieved from shading of residential air conditioning (AC) condenser units. The investigation consisted of before-and-after experiments conducted on three homes over a two year period. A recent EPA study recommends shading of exterior AC condensers, using landscaping or other means, as a method to reduce space cooling energy use (Akbari et al., 1992).

Parker, D. S.; Barkaszi, S. F.; Sonne, J. K.

1996-01-01T23:59:59.000Z

102

De-icing thermostat for air conditioners  

SciTech Connect

This patent describes an electronic thermostat adapted to be connected to an air-cooling apparatus to control the operative state of the apparatus. The thermostat includes a means for generating a digital electrical signal representative of a desired temperature setpoint and means for generating a digital electrical signal representative of the ambient temperature at the thermostat. The improvement described here comprises: means for generating control signals for the aircooling apparatus in order to inhibit the accumulation of ice on the cooling element of the air-cooling apparatus when the ambient temperature is above the temperature setpoint; means, responsive to the control signals, for deenergizing the compressor in the air-cooling apparatus for a first preselected period of time whenever the compressor is determined to have run continuously for a second preselected period of time; and means for adaptively adjusting the length of at least one of the first or second preselected periods of time as a function of the change in the rate of change of the ambient temperature.

Levine, M.R.

1986-12-09T23:59:59.000Z

103

Conservation for window air conditioners: a guide for homeowners and weatherization crews  

SciTech Connect

Recommendations are made on the maintenance, operation, and shading of existing window air conditioners for the purpose of helping home owners conserve energy. (LCL)

Riley, J.T.; Haumberger, H. Jr.; Riley, K.L.

1978-01-01T23:59:59.000Z

104

Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications: Preprint  

DOE Green Energy (OSTI)

A novel liquid-desiccant air conditioner that dries and cools building supply air will transform the use of direct-contact liquid-desiccant systems in HVAC applications, improving comfort, air quality, and providing energy-efficient humidity control.

Lowenstein, A.; Slayzak, S.; Kozubal, E.

2006-07-01T23:59:59.000Z

105

Variable Speed Fan Retrofits for Computer Room Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Variable-Speed Fan Variable-Speed Fan Retrofits for Computer-Room Air Conditioners Prepared for the U.S. Department of Energy Federal Energy Management Program Technology Case Study Bulletin By Lawrence Berkeley National Laboratory Steve Greenberg September 2013 2 Contacts Steve Greenberg Lawrence Berkeley National Laboratory One Cyclotron Road, 90R3111 Berkeley, California 94720 (510) 486-6971 segreenberg@lbl.gov For more information on FEMP, please contact: Will Lintner, P.E., CEM Federal Energy Management Program U.S. Department of Energy 1000 Independence Ave. S.W. Washington, D. C. 20585-0121 (202) 586-3120 william.lintner@ee.doe.gov 3 Acknowledgements EPRI: Dennis Symanski, Brian Fortenbery Synapsense: Garret Smith, Patricia Nealon Vigilent: Corinne Vita

106

Laboratory Performance Testing of Residential Window Mounted Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Laboratory Performance Testing of Residential Window Mounted Air Conditioners Jon Winkler Chuck Booten Dane Christensen Jeff Tomerlin April 29, 2012 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Why should we care? * Window AC unit sales dominate US market o 7.5 million units sold in 2011 - 36% more than ducted systems - Approx. 30% of installed capacity o Inexpensive relative to central units o Easy installation o Attractive for retrofits * Need accurate models in whole-building tools o Costs/savings relative to other solutions can be quantified o Spot cooling can reduce energy use, but when, where and by

107

Influence of Air Conditioner Operation on Electricity Use and Peak Demand  

E-Print Network (OSTI)

Electricity demand due to occupant controlled room air conditioners in a large mater-metered apartment building is analyzed. Hourly data on the electric demand of the building and of individual air conditioners are used in analyses of annual and time-of-day peaks. Effects of occupant schedules and behavior are examined. We conclude that room air conditioners cause a sharp annual peak demand because occupants have strongly varying thresholds with respect to toleration of high indoor temperatures. However, time-or-day peaking is smoothed by air conditioning in this building due to significant off-peak operation of air conditioners by some occupants. If occupants were billed directly for electricity, off-peak use would probably diminish making the peaks more pronounced and exacerbating the utility company's load management problems. Future studies of this type in individually metered apartment buildings are recommended.

McGarity, A. E.; Feuermann, D.; Kempton, W.; Norford, L. K.

1987-01-01T23:59:59.000Z

108

Cromer Cycle Air Conditioner: A Unique Air-Conditioner Desiccant Cycle to Enhance Dehumidification and Save Energy  

E-Print Network (OSTI)

The Cromer cycle uses a desiccant to move moisture from the saturated air leaving an air conditioning (AC) cooling coil to the air returning to the AC unit from the conditioned space. This has the thermodynamic effect of reducing the overall energy consumption of the AC unit and also has the side benefit of dramatically increasing the moisture removal capacity of the AC coil. Simulations, engineering analysis and laboratory tests have confirmed the technical feasibility of the thermodynamics of the cycle. This work reports on a test at ARI conditions (95 deg. F outside, 80 deg F, 51% RH inside). The test unit (10 year old, 5 ton Bryant Air Conditioner) without the Cromer cycle, averaged an EER of 7.93 at a latent ratio of 26.2 % (SHR = 0.738). With the Cromer cycle added, the same unit averaged a total cooling EER of 11.82 with a water removal latent ratio of 53.4% (SHR= 0.466). The measured 16.4% reduction in energy use and 47.9 improvement in EER is significant for the tests at the 95% confidence level. This technology represents a major improvement in energy performance for the control of humidity conditions.

Cromer, C. J.

2000-01-01T23:59:59.000Z

109

An Evaluation of Steady-State Dehumidification Characteristics of Residential Central Air Conditioners, Final Report  

E-Print Network (OSTI)

This report is the first of two reports on the project "Determination of the Transient Response Characteristics of High Efficiency Commercial Air Conditioners" funded by Houston Lighting and Power Company. The purpose of this report is to present the results from an investigation of the possible relationship between residential central air conditioner efficiency and dehumidification performance. The method used was that of a survey of air conditioners currently manufactured and on the market as of late 1986. Chapter 2 outlines the basic terminology used in evaluating the dehumidification performance of central air conditioners. Chapter 3 provides background to the survey data. Chapter 4 presents results from the survey. Conclusions and recommendations are presented in Chapter 5.

O'Neal, D. L.; Chan, N.; Somasundaram, S.; Katipamula, S.

1987-01-01T23:59:59.000Z

110

Building America Top Innovations 2013 Profile ツ High-Efficiency Window Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

inexpensive, portable, and can be installed by inexpensive, portable, and can be installed by home occupants, making them a good solution for supplemental cooling, for installing air conditioning in homes that lack ductwork, and for renters. As a result, 7.5 million window air conditioners are purchased each year in the United States-more than all other home cooling equipment combined. However, a window air conditioner is required to meet only modest minimum efficiency standards, and its typical installation in a window causes air leakage, which significantly reduces the equipment's performance. To measure the impact these products have on home energy use, researchers at the National Renewable Energy Laboratory (NREL) studied the performance of one 10-year-old and three new window air conditioners in a range of

111

Analysis and optimization of an adsorption air conditioner for electric vehicle applications  

SciTech Connect

This paper shows an analysis of the applicability of an adsorption system for electric vehicle (EV) air conditioning. Adsorption systems are designed and optimized to provide the required cooling for four combinations of vehicle characteristics and driving cycles. The resulting adsorption systems are compared with vapor compression air conditioners that can satisfy the cooling load. The objective function is the overall system weight, which includes the cooling system weight and the weight of the battery necessary to provide energy for air conditioner operation. The system with the minimum overall weight is considered to be the best. The results show the optimum values of all the variables, as well as temperatures and amounts adsorbed, for the adsorption and desorption processes. The results indicate that, for the conditions analyzed in this paper, vapor compression air conditioners are superior to adsorption systems, not only because they are lighter, but also because they have a higher COP and are more compact.

Aceves, S.M.

1994-07-27T23:59:59.000Z

112

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

SciTech Connect

This report describes an analysis of the economic impacts of possible energy efficiency standards for commercial unitary air conditioners and heat pumps on individual customers in terms of two metrics: life-cycle cost (LCC) and payback period (PBP). For each of the two equipment classes considered, the 11.5 EER provides the largest mean LCC savings. The results show how the savings vary among customers facing different electricity prices and other conditions. At 11.5 EER, at least 80% of the users achieve a positive LCC savings. At 12.0 EER, the maximum efficiency analyzed, mean LCC savings are lower but still positive. For the {ge} $65,000 Btu/h to <135,000 Btu/h equipment class, 59% of users achieve a positive LCC savings. For the $135,000 Btu/h to <240,000 Btu/h equipment class, 91% of users achieve a positive LCC savings.

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-03-31T23:59:59.000Z

113

The Effect of Reduced Evaporator Air Flow on the Performance of a Residential Central Air Conditioner  

E-Print Network (OSTI)

This paper discusses the measured degradation in performance of a residential air conditioning system operating under reduced evaporator air flow. Experiments were conducted using a R-22 three-ton split-type cooling system with a short-tube orifice expansion device. Results are presented here for a series of tests in which the evaporator air flow was reduced from 25 to 90% below what is normally recommended for this air conditioner. At present, very little information is available which quantifies the performance of a residential cooling system operating under degraded conditions such as reduced evaporator air flow. Degraded performance measurements can provide information which could help electric utilities evaluate the potential impact of system-wide maintenance programs.

Palani, M.; O'Neal, D.; Haberl, J.

1992-05-01T23:59:59.000Z

114

Swozzle based burner tube premixer including inlet air conditioner for low emissions combustion  

DOE Patents (OSTI)

A burner for use in a combustion system of a heavy-duty industrial gas turbine includes a fuel/air premixer having an air inlet, a fuel inlet, and an annular mixing passage. The fuel/air premixer mixes fuel and air into a uniform mixture for injection into a combustor reaction zone. The burner also includes an inlet flow conditioner disposed at the air inlet of the fuel/air premixer for controlling a radial and circumferential distribution of incoming air. The pattern of perforations in the inlet flow conditioner is designed such that a uniform air flow distribution is produced at the swirler inlet annulus in both the radial and circumference directions. The premixer includes a swozzle assembly having a series of preferably air foil shaped turning vanes that impart swirl to the airflow entering via the inlet flow conditioner. Each air foil contains internal fuel flow passages that introduce natural gas fuel into the air stream via fuel metering holes that pass through the walls of the air foil shaped turning vanes. By injecting fuel in this manner, an aerodynamically clean flow field is maintained throughout the premixer. By injecting fuel via two separate passages, the fuel/air mixture strength distribution can be controlled in the radial direction to obtain optimum radial concentration profiles for control of emissions, lean blow outs, and combustion driven dynamic pressure activity as machine and combustor load are varied.

Tuthill, Richard Sterling (Bolton, CT); Bechtel, II, William Theodore (Scotia, NY); Benoit, Jeffrey Arthur (Scotia, NY); Black, Stephen Hugh (Duanesburg, NY); Bland, Robert James (Clifton Park, NY); DeLeonardo, Guy Wayne (Scotia, NY); Meyer, Stefan Martin (Troy, NY); Taura, Joseph Charles (Clifton Park, NY); Battaglioli, John Luigi (Glenville, NY)

2002-01-01T23:59:59.000Z

115

NREL: Vehicle Ancillary Loads Reduction - Air Conditioner Reduction Project  

NLE Websites -- All DOE Office Websites (Extended Search)

Conditioner Reduction Project to Reduce Vehicle Fuel Use by 30% Conditioner Reduction Project to Reduce Vehicle Fuel Use by 30% United States map depicting number of millions of gallons of cooling and dehumidification by state: Alabama 167, Alaska 1, Arizona 43, Arkansas 86, California 730, Colorado 76, Connecticut 61, Delaware 19, Florida 753, Georgia 251, Hawaii 68, Idaho 26, Illinois 242, Indiana 142, Iowa 68, Kansas 75, Kentucky 95, Louisiana 176, Maine 21, Maryland 118, Massachusetts 86, Michigan 186, Minnesota 86, Mississippi 85, Missouri 144, Montana 12, Nebraska 40, Nevada 61, New Hampshire 90, New Jersey 167, New Mexico 52, New York 273, North Carolina 187, North Dakota 12, Ohio 229, Oklahoma 109, Oregon 66, Pennsylvania 238, Rhode Island 15, South Carolina 127, South Dakota 17, Tennessee 179, Texas 735, Utah 43, Vermont 9, Virginia 187, Washington 64, West Virginia 37, Wisconsin 167, and Wyoming 7

116

Performance of an experimental solar-driven absorption air conditioner. Annual report, July 1975--September 1976  

DOE Green Energy (OSTI)

An important pathway for the use of solar energy for space conditioning of buildings is the development of a heat-actuated air conditioner that can operate with the temperatures available from flat-plate solar collectors and use air cooling for disposal of the waste heat. The solar heating and cooling program of the Lawrence Berkeley Laboratory is exploring the use of the ammonia-water absorption cycle for this purpose. Results of the initial tests of an experimental system that has been fabricated to provide basic engineering data on the operation of the ammonia-water absorption cycle under such conditions are presented. A nominal three-ton, continuous operation, heat-actuated water chiller has been fabricated by drastic modification of a commercial gas-fired unit. The major modifications included designing a new water-heated generator, adding a preheater to the solution circuit, and increasing the flow rate of solution by a factor of about three. The unit was instrumented for measurement of temperatures, pressures, and solution concentrations at points in the circuit. Twenty-two experimental runs have been made and the results analyzed. An analysis of the thermodynamic cycle which includes the finite effectiveness of heat transfer at various points in the cycle is shown to predict with good accuracy the measured values of COP. The measured coefficient of performance agreed with the calculated values over the range 0.4 to 0.75 as the conditions of individual runs were varied. The agreement with the calculated values was within about 5 percent.

Dao, K.; Simmons, M.; Wolgast, R.; Wahlig, M.

1977-01-01T23:59:59.000Z

117

Modeling the effects of Refrigerant Charging on Air Conditioner Performance Characteristics For Three Expansion Devices  

E-Print Network (OSTI)

An experimental and analytical study concerned with the off-design refrigerant charging of air conditioners is presented. A series of experiments were conducted to characterize the effects of refrigerant charge and type of expansion device on the system performance (capacity, EER, SEER, etc.) of an air conditioner. All experiments were performed according to the ASHRAE Standard [1983]. The effects of off-design refrigerant charge in the system, type of expansion device (capillary tube, TXV, and short-tube orifice), and outdoor dry-bulb temperature (82ー to l00ーF) on the wet and dry steady state and cyclic tests are addressed in this study. The fully charged condition was established as a base case for all the expansion device systems. A full charge was obtained by charging the unit to the superheat or subcooled condition specified by the manufacturer charging chan. Once the full charge was determined, refrigerant was then added in 5% increments from -20% of full charge to +20% of full charge to cover the full range of charging conditions for a particular expansion device being tested. The investigation of off-design charging indicated that the system performance variables (total capacity, EER, and SEER) of the unit with capillary tube were more sensitive to off-design charging than the systems with TXV and short-tube orifice. From -20% to +20% charging, the capacity and EER showed a strong dependence on the outdoor temperature, but varied little with charge for the TXV and short-tube orifice expansion systems. A -20% charging resulted in a 21% reduction in SEER while a +20% charging produced an 11% reduction in SEER for the unit with capillary tube. For the TXV, SEER dropped 2% and 8% for -20% and +20% refrigerant charging, respectively. The SEER was constant at 9.4 for all the charging condition except for -5% charging where it peaked to 9.9 for the short-tube orifice expansion system. This trend would suggest that the range of sensitivity of a short-tube orifice system is confined within a small refrigerant charge. A new heat exchanger model based on tube-by-tube simulation was developed and integrated into the ORNL heat pump model. The model was capable of simulating the steady state response of a vapor compression air-to-air heat pump and air conditioner commonly used in residential applications. The simulated results were compared with laboratory tests at two outdoor temperatures. It was found that the ORNL model estimates were within an average of 3% of the experimental results from - 10% to +10% charging conditions. The model predicted the system performance up to 8% higher than measured results at +/-20% and +/-15% charging conditions. Among the eight void fraction models studied, the Hughmark model showed the best agreement between superheat and subcooled temperatures, refrigerant flow rate and capacity and the measured results.

Farzad, Mohsen

1990-08-01T23:59:59.000Z

118

The Oklahoma Field Test: Air-conditioning electricity savings from standard energy conservation measures, radiant barriers, and high-efficiency window air conditioners  

SciTech Connect

A field test Involving 104 houses was performed in Tulsa, Oklahoma, to measure the air-conditioning electricity consumption of low-income houses equipped with window air conditioners, the reduction in this electricity consumption attributed to the installation of energy conservation measures (ECMS) as typically installed under the Oklahoma Weatherization Assistance Program (WAP), and the reduction achieved by the replacement of low-efficiency window air conditioners with high-efficiency units and the installation of attic radiant barriers. Air-conditioning electricity consumption and indoor temperature were monitored weekly during the pre-weatherization period (June to September 1988) and post-weatherization period (May to September 1989). House energy consumption models and regression analyses were used to normalize the air-conditioning electricity savings to average outdoor temperature conditions and the pre-weatherization indoor temperature of each house. The following conclusions were drawn from the study: (1) programs directed at reducing air-conditioning electricity consumption should be targeted at clients with high consumption to improve cost effectiveness; (2) replacing low-efficiency air conditioners with high-efficiency units should be considered an option in a weatherization program directed at reducing air-conditioning electricity consumption; (3) ECMs currently being installed under the Oklahoma WAP (chosen based on effectiveness at reducing space-heating energy consumption) should continue to be justified based on their space-heating energy savings potential only; and (4) attic radiant barriers should not be included in the Oklahoma WAP if alternatives with verified savings are available or until further testing demonstrates energy savings or other benefits in this typo of housing.

Ternes, M.P.; Levins, W.P.

1992-08-01T23:59:59.000Z

119

Measuring Short-term Air Conditioner Demand Reductions for Operations and  

NLE Websites -- All DOE Office Websites (Extended Search)

Measuring Short-term Air Conditioner Demand Reductions for Operations and Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement Title Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement Publication Type Report LBNL Report Number LBNL-5330E Year of Publication 2012 Authors Bode, Josh, Michael J. Sullivan, and Joseph H. Eto Pagination 120 Date Published 01/2012 Publisher LBNL City Berkeley Keywords consortium for electric reliability technology solutions (certs), electricity markets and policy group, energy analysis and environmental impacts department Abstract Several recent demonstrations and pilots have shown that air conditioner (AC) electric loads can be controlled during the summer cooling season to provide ancillary services and improve the stability and reliability of the electricity grid. A key issue for integration of air conditioner load control into grid operations is how to accurately measure shorter-term (e.g., ten's of minutes to a couple of hours) demand reductions from AC load curtailments for operations and settlement. This report presents a framework for assessing the accuracy of shorter-term AC load control demand reduction measurements. It also compares the accuracy of various alternatives for measuring AC reductions - including methods that rely on regression analysis, load matching and control groups - using feeder data, household data and AC end-use data. A practical approach is recommended for settlement that relies on set of tables, updated annually, with pre-calculated load reduction estimates. The tables allow users to look up the demand reduction per device based on the daily maximum temperature, geographic region and hour of day and simplify the settlement process.

120

Laboratory Testing of the Heating Capacity of Air-Source Heat Pumps at Low Outdoor Temperature Conditions  

Science Conference Proceedings (OSTI)

Air-source heat pump systems offer an alternative to the common heating, ventilating, and air conditioning (HVAC) configuration of single split unitary air conditioners with gas heating. In simple terms, heat pumps are traditional air conditioning units with the added capability of running in reverse as required by the building load. Thus, where the traditional air conditioning unit has an indoor evaporator to remove heat from the space and an outdoor condenser to reject heat to the ambient environment, ...

2010-12-22T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Save Money and Stay Cool with an Efficient, Well-Maintained Air Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner June 29, 2010 - 7:30am Addthis Eric Barendsen Energy Technology Program Specialist, Office of Energy Efficiency and Renewable Energy OK. It's officially summer here in Washington, D.C. I'm seeking the coolest, shadiest places possible as I get ready for the hottest few months of the year. It's already been a hot June in much of the country, and it may end up being one of the hottest Junes on record in DC. Naturally, I'm starting to think about how I'm going to stay cool this summer, while trying to minimize my energy use. Drew provided some excellent tips on summertime energy savings in his blog post two weeks ago,

122

Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Save Money and Stay Cool with an Efficient, Well-Maintained Air Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner June 29, 2010 - 7:30am Addthis Eric Barendsen Energy Technology Program Specialist, Office of Energy Efficiency and Renewable Energy OK. It's officially summer here in Washington, D.C. I'm seeking the coolest, shadiest places possible as I get ready for the hottest few months of the year. It's already been a hot June in much of the country, and it may end up being one of the hottest Junes on record in DC. Naturally, I'm starting to think about how I'm going to stay cool this summer, while trying to minimize my energy use. Drew provided some excellent tips on summertime energy savings in his blog post two weeks ago,

123

The Impact of Residential Air Conditioner Charging and Sizing on Peak Electrical Demand  

E-Print Network (OSTI)

Electric utilities have had a number of air conditioner rebate and maintenance programs for many years. The purpose of these programs was to improve the efficiency of the stock of air conditioning equipment and provide better demand-side management. This paper examines the effect of refrigerant charging (proper servicing of the equipment), system sizing, and efficiency on the steady-state, coincident peak utility demand of a residential central air conditioning system. The study is based on the results of laboratory tests of a three-ton, capillary tube expansion, split-system air conditioner, system capacity and efficiency data available from manufacturer's literature, and assumptions about relative sizing of the equipment to cooling load on a residence. A qualitative discussion is provided concerning the possible impacts of transient operation and total energy use on utility program decisions. The analysis indicates that proper sizing of the unit is the largest factor affecting energy demand of the three factors (sizing, charging, and efficiency) studied in this paper. For typical oversizing of units to cooling loads in houses, both overcharging and undercharging showed significant negative impact on peak demand. The impacts of SEER changes in utility peak demand were found to be virtually independent of oversizing. For properly sized units, there was a small peak benefit to higher efficiency air conditioners.

Neal, L.; O'Neal, D. L.

1992-05-01T23:59:59.000Z

124

Issue and Improvement Measure of Multi-split Air Conditioner  

Science Conference Proceedings (OSTI)

Existing problems of traditional air source variable refrigerant flow (VRF) air-conditioning system are analyzed. The disadvantages of traditional VRF air-conditioning system are described in detail: 1) its properties are seriously affected by outdoor ... Keywords: energy saving, simulation, variable refrigerant flow air conditioning, water loop

Sun Tingting; Ni Long; Yao Yang; Ma Zuiliang; Yi Lingli

2011-02-01T23:59:59.000Z

125

Analysis and design of a solar-powered liquid-desiccant air conditioner for use in hot and humid climates  

SciTech Connect

An experimental and theoretical investigation of the feasibility of a solar-powered liquid-desiccant air conditioner, for use in hot and humid climates, was carried out at the Mechanical Engineering Department, University of Florida. The proposed liquid desiccant system used nonadiabatic contactors, packed with finned-tube coils, for both moist air dehumidification and liquid-desiccant regeneration. A theoretical model was developed to analyze the complex phenomena of simultaneous heat and mass transfer in nonadiabatic contactors, as well as the continuous interaction between the dehumidification and regeneration processes. A computer code was written to assist in the analysis of the dehumidification and regeneration processes separately and coupled, for continuous operation. It was used to investigate the interaction between the different controlling parameters and their effects on the overall performance of the desiccant system. A fully solar-powered liquid-desiccant air-conditioner, with three tons of capacity was designed and optimized including economical criteria. The overall coefficient of performance (COP) of the optimized system was determined to be 0.312.

Chebbah, A.

1987-01-01T23:59:59.000Z

126

Techno-Economic Analysis of Indian Draft Standard Levels for RoomAir Conditioners  

SciTech Connect

The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency. In support of BEE's refrigerator program, Lawrence Berkeley National Laboratory (LBNL) produced an analysis of national impacts of standards in collaboration with the Collaborative Labeling and Standards Program (CLASP). That analysis drew on LBNL's experience with standards programs in the United States, as well as many other countries. Subsequently, as part of the process for setting optimal levels for air conditioner regulations, CLASP commissioned LBNL to provide support to BEE in the form of a techno-economic evaluation of air conditioner efficiency technologies. This report describes the methodology and results of this techno-economic evaluation. The analysis consists of three components: (1) Cost effectiveness to consumers of efficiency technologies relative to current baseline. (2) Impacts on the current market from efficiency regulations. (3) National energy and financial impacts. The analysis relied on detailed and up-to-date technical data made available by BEE and industry representatives. Technical parameters were used in conjunction with knowledge about air conditioner use patterns in the residential and commercial sectors, and prevailing marginal electricity prices, in order to give an estimate of per-unit financial impacts. In addition, the overall impact of the program was evaluated by combining unit savings with market forecasts in order to yield national impacts. LBNL presented preliminary results of these analyses in May 2006, at a meeting of BEEs Technical Committee for Air Conditioners. This meeting was attended by a wide array of stakeholder, including industry representatives, engineers and consumer advocates. Comments made by stakeholders at this meeting are incorporated into the final analysis presented in this report. The current analysis begins with the Rating Plan drafted by BEE in 2006, along with an evaluation of the market baseline according to test data submitted by manufacturers. MEPS, label rating levels, and baseline efficiencies are presented in Section 2. First, we compare Indian MEPS with current standards in other countries, and assess their relative stringency. Baseline efficiencies are then used to estimate the fraction of models likely to remain on the market at each phase of the program, and the impact on market-weighted efficiency levels. Section 3 deals with cost-effectiveness of higher efficiency design options. The cost-benefit analysis is grounded in technical parameters provided by industry representatives in India. This data allows for an assessment of financial costs and benefits to consumers as a result of the standards and labeling program. A Life-Cycle Cost (LCC) calculation is used to evaluate the impacts of the program at the unit level, thus providing some insight into the appropriateness of the levels chosen, and additional opportunities for further ratcheting. In addition to LCC, we also calculate payback periods, cost of conserved energy (CCE), and return on investment (ROI). Finally, Section 4 covers national impacts. This is an extension of unit level estimates in the two previous sections. Extrapolation to the national level depends on a forecast of air conditioner purchases (shipments), which we describe here. Following the cost-benefit analysis, we construct several efficiency scenarios including the BEE plan, but also considering further potential for efficiency improvement. These are combined with shipments through a stock accounting model in order to forecast air conditioner energy consumption

McNeil, Michael A.; Iyer, Maithili

2007-03-01T23:59:59.000Z

127

Thermal Energy Storage: Assessment of Ice Bear 30 Hybrid Air Conditioner  

Science Conference Proceedings (OSTI)

This report describes and documents the construction, performance, and application of a thermal energy storage system that uses ice as the storage medium. The system, Ice Bear 30 manufactured by Ice Energy Inc. located in Windsor, Colorado, is designed to provide cooling to interior spaces by circulating refrigerant within an additional evaporator coil added to a standard roof-top air conditioner. Ice storage systems exist, but what makes the Ice Bear 30 unique is its relatively small size (5 ton) for us...

2008-12-23T23:59:59.000Z

128

Estimating Air Conditioner Loads Using Available Billing and Weather Data: An Exploratory Analysis  

Science Conference Proceedings (OSTI)

In limited testing, an innovative statistical technique for estimating the effects of residential air conditioners on system loads under various weather conditions produced encouraging results. The simple technique, which uses standard utility billing records and readily available weather data, could offer an inexpensive alternative to household monitoring. This report is available only to funders of Program 101A or 101.001. Funders may download this report at http://my.primen.com/Applications/DE/Commun...

1985-10-25T23:59:59.000Z

129

Determination of the Transient Dehumidification Characteristics of High Efficiency Central Air Conditioners  

E-Print Network (OSTI)

A series of tests were performed to assesses the dehumidifying performance of residential central air conditioners (CACs). The performance studies were based on factors such as: (i) dynamic performance (ii) the ASHRAE comfort zone, (iii) control strategy and (iv) published performance characteristic of the units. The units were evaluated on their ability to maintain conditions in the ASHRAE comfort zone in a typical residence and typical summer days in Houston, Texas.

Katipamula, S.; O'Neal, D. L.; Somasundaram, S.

1987-01-01T23:59:59.000Z

130

A Preliminary Evaluation of Alternative Liquid Desiccants for a Hybrid Desiccant Air Conditioner  

E-Print Network (OSTI)

This paper presents the results of a preliminary investigation at The University of Texas at Austin of alternative liquid desiccants for use in a hybrid desiccant air-conditioning system in which a desiccant is circulated between the evaporator and the condenser of a vapor-compression air conditioner. The liquid desiccants studied were lithium chloride, lithium bromide, calcium chloride, and triethylene glycol. Each candidate desiccant was subjected to a screening process which weighed the merits of the desiccant in terms of selected characteristics. The best liquid desiccant for the anticipated application was found to be calcium chloride.

Studak, J. W.; Peterson, J. L.

1988-01-01T23:59:59.000Z

131

Passive features for a liquid desiccant air conditioner  

SciTech Connect

A conceptual development program with the ultimate objective of substantially reducing or eliminating the parasitic power requirement for liquid sorbent air conditioning systems is described. Operational tests conducted on small prototypes have shown that some of the pumps can be replaced with other apparatus requiring no electrical energy. Experimental work has also shown that some electric utility dependent pumps might be replaced by solar powered pumps thus making the system more passive in nature.

Francis, C.E.; Beavers, D.R.

1980-01-01T23:59:59.000Z

132

A liquid over-feeding military air conditioner  

SciTech Connect

A 3-ton military air conditioning unit has been experimentally studied for baseline and liquid over-feeding operation (LOF). The test results indicate that LOF outperforms the baseline case over a wide ambient temperature range in terms of cooling capacity, power consumption, and system coefficient of performance (COP). At 95 F test point, the COP improvement for LOF is 19.8% over that of the baseline case. However, optimal refrigerant charge is essential for LOF to work properly.

Mei, V.C.; Chen, F.C. [Oak Ridge National Lab., TN (United States); Bolton, C. [Army CECOM Research, Development, and Engineering Center, Fort Belvoir, VA (United States)

1995-09-01T23:59:59.000Z

133

Measure Guideline: Air Conditioner Diagnostics, Maintenance, and Replacement  

SciTech Connect

This guideline responds to the need for an efficient means of identifying, diagnosing, and repairing faults in air conditioning systems in existing homes that are undergoing energy upgrades. Inadequate airflow due to constricted ducts or undersized filters, improper refrigerant charge, and other system defects can be corrected at a fraction of the cost of equipment replacement and can yield significant savings. The guideline presents a two-step approach to diagnostics and repair.

Springer, D.; Dakin, B.

2013-03-01T23:59:59.000Z

134

A liquid over-feeding military air conditioner  

SciTech Connect

A 3.3-ton military air conditioning unit has been studied experimentally in both baseline (as received) and as modified for liquid over-feeding (LOF) operation. Tne baseline test, using a proper refrigerant charge, showed the measured cooling capacity to be less than 1% off the rated capacity at 95{degrees}F ambient temperature. The test results indicate that LOF operation outperforms the baseline case over a wide ambient temperature range in terms of cooling capacity, power consumption, and system coefficient of performance (COP). At a 95{degrees}F test point, LOF operation has a cooling capacity of 51,100 BTU per hour, which is a 28.9% improvement over the baseline operation capacity of 39,600 BTU per hour. The COP for LOF at 95{degrees}F is 2.62, which is 29% better than the baseline COP of 2.03. However, an optimal refrigerant charge is essential for LOF to work properly.

Mei, V.C.; Chen, F.C.

1995-07-01T23:59:59.000Z

135

Effects of Air Conditioner Use on Real-World Fuel Economy  

Science Conference Proceedings (OSTI)

Vehicle data were acquired on-road and on a chassis dynamometer to assess fuel consumption under several steady cruise conditions and at idle. Data were gathered for various air conditioner (A/C) settings and with the A/C off and the windows open. Two vehicles were used in the comparisonstudy: a 2009 Ford Explorer and a 2009 Toyota Corolla. At steady speeds between 64.4 and 112.7 kph (40 and 70 mph), both vehicles consumed more fuel with the A/C on at maximum cooling load (compressor at 100% duty cycle) than when driving with the windows down. The Explorer maintained this trend beyond 112.7 kph (70 mph), while the Corolla fuel consumption with the windows down matched that of running the A/C at 120.7 kph (75 mph), and exceeded it at 128.7 kph (80 mph). The largest incremental fuel consumption rate penalty due to air conditioner use occurred was nearly constant with a weakslight trend of increasing consumption with increasing compressor (and vehicle) speed. Lower consumption is seenobserved at idle for both vehicles, likely due to the low compressor speed at this operating point

Huff, Shean P [ORNL; West, Brian H [ORNL; Thomas, John F [ORNL

2013-01-01T23:59:59.000Z

136

Energy Basics: Solar Air Heating  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

EERE: Energy Basics Solar Air Heating Solar air heating systems use air as the working fluid for absorbing and transferring solar energy. Solar air collectors (devices to heat air...

137

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

National Energy Consumption conditioner. National Energy Consumption When regulationsThe total energy consumption (NEC) of the national stock of

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

138

The Influence of Operating Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner  

E-Print Network (OSTI)

A field investigation was carried out in an office building of Changsha city in winter and summer, the influence of different running modes, curtain styles and room temperature set point on energy consumption of room air conditioner (RAC) was studied. The results show that: In summer automatic speed mode consumes the least refrigerating energy in different running modes, compared with low speed and high speed modes, it can conserve energy for 27.3% and 15.8%, respectively. In the same running mode, setting outer curtain can conserve energy for 40.9% and 20.4% compared with no curtain and inner curtain states, respectively. In winter high speed mode is the most efficient for saving energy which can decrease 40.3% and 30.9% compared with low speed and automatic speed modes. In the same running mode, setting inner curtain state makes the least heating energy consumption in cloudy day, about 10.8% and 2.7% less than no curtain and outer curtain states. However, it is not obvious when the day is fine. The heating energy consumption decreases as room temperature set point falls, compared with the energy consumption at 20.5 C and 19.5 C, it is decreases for 34.1% and17.0 % at 18.5 C, respectively. All the results will be the reference of environment design and control for air conditioning room.

Yu, J.; Yang, C.; Guo, R.; Wu, D.; Chen, H.

2006-01-01T23:59:59.000Z

139

A cost-effective and fuel-conserving nonelectric air conditioner that combines engine-driven compression and absorption cycles  

SciTech Connect

A natural-gas-fueled electricity-producing condensing furnace with the potential of being mass produced at a cost of less than $1000 and providing a cost-effective and highly fuel-conserving alternative to virtually every residential gas furnace in the world has been developed. While this is a new system, it completely consists of existing mass-produced components including single-cylinder air-cooled engines, induction motors/generators, and control devices. Thus, timely commercialization can be expected and an important new energy technology and industry can result. However, all the benefits of this electricity-producing furnace occur during the winter. This has stimulated the search for a new system that can provide comparable benefits in terms of fuel conservation, the environment, and electric utility peak reduction during the summer, along with the prospects of a new and efficient new use for the natural gas surpluses that occur during the summer. The resulting system, which can use existing component equipment, is a commercial-size nonelectric air conditioner that consists of an automobile-type engine converted to natural gas, or possibly a diesel or combustion turbine, driving a Freon compression cycle, with virtually all of the engine reject heat from the exhaust and from the engine cooling system driving a conventional absorption air conditioning cycle.

Wicks, F.

1988-01-01T23:59:59.000Z

140

Investigations on Vapour Compression Air Conditioner with Direct Contact Desiccant Loop over Condenser and Evaporator  

E-Print Network (OSTI)

Perceived air quality increases when relative humidity is decreased till about 30% in the range of comfort temperature. In the present scenario, humidity is considered as a pollutant. Hence, a controlled environment not only at low temperature but also at low humidity is desired for many applications such as archives, data centers, etc. Either a separate dehumidifier or a precision air conditioning (AC) system needs to be employed for such an application. In fact, the latter forms a reheat AC system which happens to be energy inefficient. In view of this, a vapor compression window air conditioner is investigated with a superimposed liquid desiccant loop harnessing the advantages of both the compression system (high COP) and desiccant system (low humidity). Operation of such a novel system is explained, elucidating the operational feasibility. The results presented consider the characteristics of such a system with respect to changes in the evaporator inlet air temperature and humidity. The change in the specific humidity of air is compared for vapor compression system and the direct contact hybrid system for different values of inlet air temperature.

Maiya, M. P.; Ravi, J.; Tiwari, S.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications: Preprint  

NLE Websites -- All DOE Office Websites (Extended Search)

A Zero Carryover A Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications Preprint A. Lowenstein AIL Research, Inc. S. Slayzak and E. Kozubal National Renewable Energy Laboratory To be presented at ASME International Solar Energy Conference (ISEC2006) Denver, Colorado July 8-13, 2006 Conference Paper NREL/CP-550-39798 July 2006 NOTICE The submitted manuscript has been offered by an employee of the Midwest Research Institute (MRI), a contractor of the US Government under Contract No. DE-AC36-99GO10337. Accordingly, the US Government and MRI retain a nonexclusive royalty-free license to publish or reproduce the published form of this contribution, or allow others to do so, for US Government purposes. This report was prepared as an account of work sponsored by an agency of the United States government.

142

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

NLE Websites -- All DOE Office Websites (Extended Search)

330E 330E Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement Josh Bode, Michael Sullivan, Joseph H. Eto January 2012 The work described in this report was funded by the Office of Electricity Delivery and Energy Reliability of the U.S. Department of Energy under Contract No. DE-AC02- 05CH11231. ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the University of California, nor any of their employees, makes any warranty, express or implied, or assumes any legal responsibility for the accuracy, completeness, or

143

Procuring High-Efficiency Air Conditioners: Harnessing Competition to Achieve Advances in Technology  

SciTech Connect

The Departments of Energy and Defense have joined forces to devise an innovative approach to acquiring more efficient unitary air conditioners that minimize life-cycle cost through improved technology. The resulting procurement solicitation challenges manufacturers to offer products with reduced life-cycle cost, taking into account both the initial prices of their units and the costs of their ongoing electric consumption. Competing products are evaluated according to a formula that reflects both full- and part-load efficiencies under a simulated set of time-varying climate conditions. The authors will report on the progress of the procurement, including the choice of target product based on market prospects and technology readiness, development of the technical specifications and electric consumption simulator, approaches to administrative and procedural challenges, responses from manufacturers, and plans for product promotion in the future.

Hollomon, J Bradford; Gordon, Kelly L.

2002-03-01T23:59:59.000Z

144

Modeling of a second-generation solar-driven Rankine air conditioner. Final report  

DOE Green Energy (OSTI)

Ten configurations of a second-generation (2G), solar-powered, Rankine-driven air conditioner were simulated and the data presented for use in companion studies. The results of the analysis show that the boiling-in-collector (BIC) configuration generates more power per collector area than the other configurations. The models used to simulate the configuration are presented in this report. The generated data are also presented. Experimental work was done under this study to both improve a novel refrigerant and oil lubrication system for the centrifugal compressor and investigate the aerodynamic unloading characteristics of the centrifugal compressor. The information generated was used to define possible turbo-gearbox configurations for use in the second generation computer simulation.

Denius, M.W.; Batton, W.D.

1984-07-01T23:59:59.000Z

145

Energy Basics: Supporting Equipment for Heating and Cooling Systems  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

for Heating and Cooling Systems Thermostats and ducts provide opportunities for saving energy. Dehumidifying heat pipes provide a way to help central air conditioners and heat...

146

Commissioning Tools for Heating/Cooling System in Residence - Verification of Floor Heating System and Room Air Conditioning System Performance  

E-Print Network (OSTI)

Tools of evaluating the performance of floor heating and room air conditioner are examined as a commissioning tool. Simple method is needed to check these performance while in use by residents, because evaluation currently requires significant time and effort. Therefore, this paper proposes a) two methods of evaluating the floor heating efficiency from the room / crawl space temperature and the energy consumption and b) method of evaluating COP of the room air conditioner from the data measured at the external unit. Case studies in which these tools were applied to actual residences are presented to demonstrate their effectiveness.

Miura, H.; Hokoi, S.; Iwamae, A.; Umeno, T.; Kondo, S.

2004-01-01T23:59:59.000Z

147

NREL Solves Residential Window Air Conditioner Performance Limitations (Fact Sheet), Highlights in Research & Development, NREL (National Renewable Energy Laboratory)  

NLE Websites -- All DOE Office Websites (Extended Search)

13 Denver West Parkway 13 Denver West Parkway Golden, CO 80401 303-275-3000 | www.nrel.gov Printed with a renewable-source ink on paper containing at least 50% wastepaper, including 10% post consumer waste. NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Comprehensive performance tests lead to enhanced modeling capability and affordable methods to increase energy efficiency. Window air conditioners are inexpensive, portable, and can be installed by home occupants, making them a good solution for supplemental cooling, for installing air conditioning into homes that lack ductwork, and for renters. As a result, 7.5 million window air conditioners are purchased each year in the United States-more than all other home cooling equipment

148

DSP-Based Sensor-less Permanent Magnet Synchronous Motor Driver With Quasi-Sine PWM for Air-Conditioner Rotary Compressor.  

E-Print Network (OSTI)

??This thesis presented a sensor-less permanent magnet synchronous motor (PMSM) driver for controlling air-conditioner rotary compressor speed. In this thesis, a quasi-sine pulse-width modulation (PWM) (more)

Liu, Li-hsiang

2012-01-01T23:59:59.000Z

149

An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with a Thermal Expansion Valve  

E-Print Network (OSTI)

The effect of the improper charging on steady state and cyclic performance (capacity, EER, power consumption, SEER, and coefficient of degradation) of a residential air conditioner which utilized a thermal expansion valve was investigated. This study was the continuation of ESL/CON/88-1 performed by Mohsen Farzad and Dennis O'Neal. A fully charged condition was established as a base case. The full charge was obtained by charging the unit to the subcooling specified by the manufacturer for a specific indoor and outdoor temperatures. Once the full charge was determined, the unit was subjected to 40%, 30%, 20%, 15%, 10%, and 5% undercharging and 5%, 10%, 15%, and 20% overcharging of refrigerant by mass. The fully charged tests were compared to those for under and overcharging. The performance of the unit was evaluated as a function of charge as well as at four outdoor room temperatures (82ーF, 90ーF, 95ーF, and 100ーF). As the outdoor temperature increased, the total capacity and EER dropped. The maximum total capacity, EER, and SEER were found at 10% undercharging (12 6 oz). The capacity and efficiency (EER and SEER) of the unit were found to be less sensitive to under/overcharging than the unit with a capillary tube expansion previously studied. Other data such as refrigerant flow rate, sensible heat ratio, superheat and subcooling were also presented.

Farzad, M.; O'Neal, D. L.

1989-01-01T23:59:59.000Z

150

An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with Capillary Tube Expansion  

E-Print Network (OSTI)

The effect of the improper charging on the performance (capacity, EER, power consumption, SEER, and coefficient of degradation) of a residential air conditioner during the steady state (wet and dry coils) and cycling operation was investigated. The fully charged condition was established as a base case. A full charge was obtained charging the unit to the superheat specified by the manufacturer's charging chart for specific set of indoor and outdoor temperatures. Once the full charge was determined, the unit was subjected to 20%, 15%, 10%, and 5% under and overcharging of refrigerant (by mass). The fully charged tests were compared to under and overcharging. The performance of the unit was evaluated as a function of charge as well as at four outdoor room temperatures (82ーF, 90ーF, 95ーF, and 100ーF). As the outdoor temperature increased, the total capacity and EER dropped. The investigation of improper charging showed that the total capacity, EER, and SEER were more sensitive to undercharging than overcharging conditions. A 20% undercharge resulted in a 21% reduction in SEER while a 20% overcharge produced a 11% reduction in SEER. Other data such as refrigerant flow rate, sensible heat ratio, superheat and subcooling are also presented.

Farzad, M.; O'Neal, D. L.

1988-01-01T23:59:59.000Z

151

Air Conditioning | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Conditioning Conditioning Air Conditioning July 1, 2012 - 6:28pm Addthis Air conditioners cost U.S. homeowners more than $11 billion each year, and regular maintenance can keep your air conditioner running efficiently. | Photo courtesy of テつゥiStockphoto/JaniceRichard Air conditioners cost U.S. homeowners more than $11 billion each year, and regular maintenance can keep your air conditioner running efficiently. | Photo courtesy of ツゥiStockphoto/JaniceRichard How does it work? An air conditioner uses energy -- usually electricity -- to transfer heat from the interior of your home to the relatively warm outside environment. Two-thirds of all homes in the United States have air conditioners. Air conditioners use about 5% of all the electricity produced in the United States, at an annual cost of more than $11 billion to homeowners. As a

152

Air heating system  

DOE Patents (OSTI)

A self-starting, fuel-fired, air heating system including a vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with the provision of heat exchanger and circuitry for cooling the condensed fluid output from the pump prior to its return to the vapor generator.

Primeau, John J. (19800 Seminole Rd., Euclid, OH 44117)

1983-03-01T23:59:59.000Z

153

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

SciTech Connect

The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptive frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.

McNeil, Michael A.; Iyer, Maithili

2009-05-30T23:59:59.000Z

154

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

SciTech Connect

The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptive frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.

McNeil, Michael A.; Iyer, Maithili

2009-05-30T23:59:59.000Z

155

Air Conditioning | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

environment. An air conditioner uses a cold indoor coil called the evaporator. The condenser, a hot outdoor coil, releases the collected heat outside. The evaporator and...

156

DOE Takes Action to Stop the Sales of Air-Con Air Conditioner...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

action against Air-Con, International, requiring the company to stop selling certain air conditioning systems in the U.S. that have been shown to violate minimum energy...

157

The System Impact of Air-Conditioner Under-voltage Protection Schemes  

Science Conference Proceedings (OSTI)

This paper presents simulation results of evaluating an under-voltage protection scheme designed to take stalled air-conditioner (a/c) units offline such that the slow voltage recovery phenomena can be solved on areas heavily loaded with a/c motors during summer peak periods. A three feeder test-bed has been first used to quantify the effectiveness of the protection scheme and the sensitivity of the under-voltage relay settings. Then two real system events of the Western US power grid have been studied to evaluate the area impact of the protection scheme proposed by Southern California Edison. The study demonstrates that by taking all or most of the stalled a/c unit offline, the feeder voltage will recover in a few seconds, much quicker than the tens of seconds that the standard thermal relays imbedded in the motors need to trip the units. The drawback of the control scheme is that after the voltage recover, it settled at a higher voltage than before the faults because a large chuck of load has been shed.

Lu, Ning; Yang, Bo; Huang, Zhenyu; Bravo, Richard

2009-03-31T23:59:59.000Z

158

Performance of an air-cooled ammonia-water absorption air conditioner at low generator temperatures  

DOE Green Energy (OSTI)

An ammonia--water absorption air conditioning system has been tested to investigate the stability of operation near the cut-off conditions. Circulation ratios were from 8 to 30. Relations for the estimation of the coefficient of performance and for the prediction of operating temperatures were derived and verified experimentally. Possible operating conditions for an air-cooled ammonia--water air conditioning system were concluded.

Dao, K.; Simmons, M.; Wolgast, R.; Wahlig, M.

1976-08-01T23:59:59.000Z

159

DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS  

E-Print Network (OSTI)

of the University of California, nor any of their employees,of the University of California. The views and opinions ofof the University of California. DEVELOPMENT OF SOLAR DRIVEN

Dao, K.

2013-01-01T23:59:59.000Z

160

Building Technologies Office: Central Air Conditioner and Heat...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Use to Save Money. Learn More. News DOE Issues Notice of Proposed Rulemaking for Commercial Refrigeration Equipment Energy Conservation Standard August 29, 2013 DOE Issues...

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Fault Detection and Diagnosis for Air-Conditioners and Heat ...  

Science Conference Proceedings (OSTI)

... Calculation of the 兎nergetic metric will include weather data to weight the ... and rooftop units and will promote market implementation of FDD tools. ...

2012-12-17T23:59:59.000Z

162

Simulation of Dehumidification Characteristics of High Efficiency Residential Central Air-Conditioners in Hot and Humid Climates  

E-Print Network (OSTI)

This study assesses the dehumidifying performance of the high efficiency residential central air conditioners (CAC) in hot/humid climates typified by that of Houston and Galveston. The performance study is based on such factors as: (i) weather (ii) thermostat set point and dead band, and (ill) sizing of unit relative to the design load of the residence. The units are evaluated on their ability to maintain conditions in the ASHRAE comfort zone in a typical residence in Houston area. The units, the thermostat, and the residence are simulated on a minute-by-minute basis using a commercial software (TRNSYS) after making certain modifications to it.

Katipamula, S.; O'Neal, D.; Somasundram, S.

1988-01-01T23:59:59.000Z

163

Experimental analysis of a window air conditioner with a R-22 and R32/R125/R134a mixture  

SciTech Connect

Much experimental and theoretical analysis of potential R-22 replacements has been accomplished. However, published information about the experimental analysis of any off-the-shelf air conditioner with a potential R-22 replacement at realistic, operating conditions is still rare. This type of work could be useful because it provides baseline data for comparing the performance of R-22 and its potential replacement at drop-in conditions. In this study, an off-the-shelf window air conditioner was tested at Air Conditioning and Refrigeration Institute (ARI)-rated indoor conditions and at different ambient temperatures, including the ARI-rated outdoor condition, with R-22 and with its potential replacement, a ternary mixture of R-32(30%)/R-125(10%)/R-134a(60%) (the ternary mixture). A test rig was built that provided for baseline operation and for the option of operating the system with a flooded evaporator by means of liquid over-feeding (LOF). The test results indicated the cooling capacity of the ternary mixture was 7.7% less than that of R-22 at 95{degrees}F ambient for baseline operation. The cooling capacity for both refrigerants improved when a flooded evaporator, or LOF, was used. For LOF operation, the cooling capacity of the ternary mixture was only 1.1% less than that of R-22. The ternary mixture had slightly higher compressor discharge pressure, a lower compressor discharge temperature, slightly lower compressor power consumption, and a higher compressor high/low pressure ratio.

Mei, V.C.; Chen, F.C.; Chen, D.T. [Oak Ridge National Lab., TN (United States); HuangFu, E.P. [USDOE, Washington, DC (United States)

1995-07-01T23:59:59.000Z

164

Energy Basics: Air-Source Heat Pumps  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Systems Air-Source Heat Pumps Ductless Mini-Split Heat Pumps Absorption Heat Pumps Geothermal Heat Pumps Supporting Equipment for Heating & Cooling Systems Water Heating...

165

PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976  

E-Print Network (OSTI)

Size and Type of the Heat Exchangers Air Cooled Condensora packed-tower counterflow heat exchanger for the generator.to strong solution heat exchanger) was added. iv. The

Dao, K.

2010-01-01T23:59:59.000Z

166

Seasonal Energy Efficiency Ratio (SEER) Investigation for Residential and Small Commercial Air-Source Heat Pumps  

Science Conference Proceedings (OSTI)

Electric utilities frequently use the seasonal energy efficiency ratio (SEER) in air conditioning肪ased incentive programs to categorize energy efficiency and to quantify financial value. For residential and small commercial unitary air conditioners and heat pumps, SEER is determined by the procedures outlined in ANSI/AHRI Standard 210/240. Within Standard 210/240, SEER is calculated based on laboratory test results and equations that follow specific assumptions regarding indoor temperature, ...

2012-12-21T23:59:59.000Z

167

Air-Con International: Noncompliance Determination and Proposed...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

to Air-Con International finding that a variety of central air conditioners and air conditioning heat pumps distributed under the Air-Con private label do not comport...

168

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

Refrigeration and Air Conditioning Industry Association Junein the context of the air conditioning industry, the profileand improvement of the air conditioning industry and the

Zhou, Nan

2010-01-01T23:59:59.000Z

169

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network (OSTI)

Prices Computed from Air Conditioning Load Reductions UsingRefrigerating and Air-Conditioning Engineers, Inc. (ASHRAE)/Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE),

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

170

Retrofitting an automotive air conditioner with HFC-134a, additive, and mineral oil. Final report, October 1992-May 1994  

Science Conference Proceedings (OSTI)

The paper gives results of an evaluation of a lubricant additive developed for use in retrofitting motor vehicle air conditioners. The additive was designed to enable HFC-134a to be used as a retrofit refrigerant with the existing mineral oil in CFC-12 systems. The goal of the project was to provide preliminary feasibility testing of the additive. The cooling effect of the test system retrofitted with HFC-134a and the oil additive was nearly the same as that of the original system with CFC 12 refrigerant. If lubricant additives prove to be successful, miscible lubricants may not be needed for retrofitting some automotive systems. The retrofitting procedure might be simplified and the cost to consumers might be reduced. It has not been determined if retrofitting systems with HFC-134a and oil additives is feasible for a wider range of operating conditions and types of equipment, including the applicability of orifice tube/suction accumulator systems.

Jetter, J.J.; Delafield, F.R.

1994-05-01T23:59:59.000Z

171

PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976  

E-Print Network (OSTI)

ーF for removing heat from the condenser and absorber coils.temperature. Air-cooled condensers and absorbers are limitedfor water- cooling the condenser was an overriding concern

Dao, K.

2010-01-01T23:59:59.000Z

172

Supporting Equipment for Heating and Cooling Systems  

Energy.gov (U.S. Department of Energy (DOE))

Thermostats and ducts provide opportunities for saving energy. Dehumidifying heat pipes provide a way to help central air conditioners and heat pumps dehumidify air. Electric and gas meters allow users to track energy use.

173

Effects of system cycling, evaporator airflow, and condenser coil fouling on the performance of residential split-system air conditioners  

E-Print Network (OSTI)

Three experimental studies were conducted to quantify the effects of system cycling, evaporator airflow, and condenser coil fouling on the performance of residential air conditioners. For all studies, the indoor dry-bulb (db) temperature was 80ーF (26.7ーC) db. The cycling study consisted of twelve transient tests conducted with an outdoor temperature of 95ーF (35ーC) db for cycle times of 6, 10, 15, and 24 minutes. Indoor relative humidities of 40%, 50%, and 60% were also considered. The evaporator airflow study consisted of twenty-four steady-state tests conducted with an indoor condition of 67ーF (19.4ーC) wet-bulb (wb) for evaporator airflows ranging from 50% below to 37.5% above rated airflow. Outdoor temperatures of 85ーF (29.4ーC) db, 95ーF (35ーC) db, and 105ーF (40.6ーC) db were also considered. The coil fouling study used a total of six condensers that were exposed to an outdoor environment for predetermined amounts of time and tested periodically. Three of the condensers were cleaned and retested during the periodic testing cycles. Testing consisted of thirty-three steady-state tests conducted with an indoor condition of 67ーF (19.4ーC) wb for outdoor exposure times of 0, 2000, 4000, and 8000 hours. Outdoor temperatures of 82ーF (27.8ーC) db and 95ーF (35ーC) db were also considered.

Dooley, Jeffrey Brandon

2004-12-01T23:59:59.000Z

174

Fault detection methods for vapor-compression air conditioners using electrical measurements  

E-Print Network (OSTI)

(cont.) This method was experimentally tested and validated on a commercially available air handler and duct system. In the second class of faults studied, liquid refrigerant, rather than vapor, enters the cylinder of a ...

Laughman, Christopher Reed.

2008-01-01T23:59:59.000Z

175

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network (OSTI)

avoid bias in the electricity bill calculations, we assignedarrive at an annual electricity bill. The difference betweenbill and multiplied it by the ratio of the total air conditioning energy use to the total building electricity

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

176

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 3, Water heaters, pool heaters, direct heating equipment, and mobile home furnaces  

SciTech Connect

This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.

Not Available

1993-11-01T23:59:59.000Z

177

Monitoring the Performance of a Residential Central Air Conditioner under Degraded Conditions on a Test Bench  

E-Print Network (OSTI)

This report presents the measured degradation in performance of a residential air conditioning system operating under degraded conditions. Experiments were conducted using a R-22 threeton split-type cooling system with a short-tube orifice expansion device. Results are presented here for a series of tests in which the various commonly occurring degraded conditions were simulated on a test bench. At present, very little information is available which quantifies the performance of a residential cooling system operating under degraded conditions. Degraded performance measurements can provide information which could help electric utilities evaluate the potential impact of systemwide maintenance programs. This report also discuss the development of a diagnostic procedure based on measurement of refrigerant and air side temperatures.

Palani, M.; O'Neal, D. L.; Haberl, J. S.

1992-01-01T23:59:59.000Z

178

Air-Conditioning Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air-Conditioning Basics Air-Conditioning Basics Air-Conditioning Basics August 16, 2013 - 1:59pm Addthis Air conditioning is one of the most common ways to cool homes and buildings. How Air Conditioners Work Air conditioners employ the same operating principles and basic components as refrigerators. Refrigerators use energy (usually electricity) to transfer heat from the cool interior of the refrigerator to the relatively warm surroundings; likewise, an air conditioner uses energy to transfer heat from the interior space to the relatively warm outside environment. An air conditioner uses a cold indoor coil called the evaporator. The condenser, a hot outdoor coil, releases the collected heat outside. The evaporator and condenser coils are serpentine tubing surrounded by aluminum fins. This tubing is usually made of copper.

179

Dehumidifying Heat Pipes | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Dehumidifying Heat Pipes Dehumidifying Heat Pipes Dehumidifying Heat Pipes June 24, 2012 - 4:32pm Addthis In order to make a room comfortable in hot, humid climates, an air conditioner must lower the indoor humidity level as well as the air temperature. If an air conditioner fails to lower the humidity adequately, the air will be cool, but will feel uncomfortably damp. Inappropriately sized air conditioners are prone to this problem; large units quickly cool the air, but cycle off before they can properly dehumidify it. In extremely humid climates, even correctly sized air conditioning equipment could fail to maintain a home at a comfortable humidity level. One technology that addresses this problem is the dehumidifying heat pipe, a device that enables an air conditioner to dehumidify better and still

180

Solar air heating system for combined DHW and space heating  

E-Print Network (OSTI)

Solar air heating system for combined DHW and space heating solar air collector PV-panel fannon-return valve DHW tank mantle cold waterhot water roof Solar Energy Centre Denmark Danish Technological Institute SEC-R-29 #12;Solar air heating system for combined DHW and space heating Sテクren テ?stergaard Jensen

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Comparison of the performance of open cycle air conditioners utilizing rotary desiccant dehumidifiers  

DOE Green Energy (OSTI)

This paper presents the results of an investigation of open cycle cooling systems using rotary desiccant dehumidifiers. Three systems, the ventilation, recirculation, and Dunkle cycles have been modeled. The performance of these systems coupled with an air-based solar system has been determined using TRNSYS simulations of system operation in four representative US climates. The system COP, fraction of the total cooling load met by the desiccant system, and fraction of the thermal energy provided by solar energy are compared. An assessment of the effect of climate and system parameters on the relative performance of the three system configurations is made. It is shown that in order to meet residential loads of 7 to 11 kW with a COP on the order of unity, systems with high effectiveness must be employed. These systems were also found to perform well when operated solely with a solar thermal input.

Jurinak, J.J.; Beckman, W.A.

1985-01-01T23:59:59.000Z

182

High-Efficiency Variable Dehumidification for Air Conditioners: ClimaStat  

SciTech Connect

Advantek has successfully developed the first low-cost technology offering significant improvement in both Seasonal Energy Efficiency (SEER) and comfort & humidity control. A production prototype was constructed based on a commercial roof top package unit. The prototype was operated under a wide range of psychrometric conditions. Test data was analyzed to identify refinements, which were implemented to further improve performance in an iterative procedure that resulted in a fully optimized technology. The latest results show an increase in dehumidification capacity of 56% with ClimaStat in full dehumidify mode vs. with ClimaStat off. Dehumidification improved by a factor of 1.7 to 1.9 meaning that the unit can provide nearly twice the water removal per unit of sensible cooling load. Performance testing results have been consistent, verifiable and repeatable. . ClimaStat cost-effectively controls humidity on-demand and improves indoor air quality while reducing annual energy costs. Test data clearly shows that ClimaStat costs 20% to 60% less to operate. ClimaStat is ready for market.

West, Michael K., Ph.D. P.E.

2006-04-30T23:59:59.000Z

183

Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study  

SciTech Connect

The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The performance degradation of R410A at higher temperatures was greater than R22. However, the R22 and R410A systems both operated normally during all tests. Visual observations of the R410A system provided no indication of vibrations or TXV hunting at high ambient outdoor test conditions with the compressor operating in the transcritical regime.

Piotr A. Domanski; W. Vance Payne

2002-10-31T23:59:59.000Z

184

Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study  

SciTech Connect

The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The performance degradation of R410A at higher temperatures was greater than R22. However, the R22 and R410A systems both operated normally during all tests. Visual observations of the R410A system provided no indication of vibrations or TXV hunting at high ambient outdoor test conditions with the compressor operating in the transcritical regime.

Piotr A. Domanski; W. Vance Payne

2002-10-31T23:59:59.000Z

185

Candidate chemical systems for air cooled solar powered, absorption air conditioner design. Part I. Organic absorbent systems  

DOE Green Energy (OSTI)

All the available experimental evidence suggests that the optimum ''organic'' absorbent/refrigerant combination would be a methane derivative with a single hydrogen atom with chlorine and fluorine atoms in the other sites, as refrigerant. This would be hydrogen bonded to an absorbent molecule containing the group =NC/sup -/O, with the substituent groups being such that no steric hindrance took place. Cycle analyses showed that the ratio of internal heat transfer to cooling would be large, probably impractically so in view of the high coefficient of performance needed for solar driven cooling and the additional handicap of heat rejection to the atmosphere. A more promising approach would be to reduce the internal heat transfer per unit of space cooling by selecting a refrigerant with a high latent heat of vaporization and selecting an absorbent with suitable properties.

Biermann, W.J.

186

Air-Source Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air-Source Heat Pumps Air-Source Heat Pumps August 19, 2013 - 11:03am Addthis Air-source heat pumps transfer heat between the inside of a building and the outside air. How...

187

Heat Pump Systems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pump Systems Pump Systems Heat Pump Systems May 16, 2013 - 5:33pm Addthis A heat pump can provide an alternative to using your air conditioner. | Photo courtesy of iStockPhoto/LordRunar. A heat pump can provide an alternative to using your air conditioner. | Photo courtesy of iStockPhoto/LordRunar. What does this mean for me? Heat pumps can supply heat, cooling, and hot water. Your climate and site will determine the type of heat pump most appropriate for your home. For climates with moderate heating and cooling needs, heat pumps offer an energy-efficient alternative to furnaces and air conditioners. Like your refrigerator, heat pumps use electricity to move heat from a cool space to a warm space, making the cool space cooler and the warm space warmer. During the heating season, heat pumps move heat from the cool outdoors into

188

Heating, Ventilation and Air Conditioning Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Presented By: WALTER E. JOHNSTON, PE Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE Heating, Ventilation and Air Conditioning (HVAC) system is to provide and maintain a comfortable environment within a building for the occupants or for the process being conducted Many HVAC systems were not designed with energy efficiency as one of the design factors 3 Air Air is the major conductor of heat. Lack of heat = air conditioning OR 4 Btu - Amount of heat required to raise one pound of water 1 F = 0.252 KgCal 1 Pound of Water = About 1 Pint of Water ~ 1 Large Glass 1 Kitchen Match Basics of Air Conditioning = 1 Btu 5 = 6 Low Cost Cooling Unit 7 8 Typical Design Conditions 75 degrees F temperature 50% relative humidity 30 - 50 FPM air movement

189

PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976  

E-Print Network (OSTI)

of the waste heat. The solar heating and cooling program ofheating. The heat source can be either a back-up system, or the solar

Dao, K.

2010-01-01T23:59:59.000Z

190

Central Air Conditioning | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Central Air Conditioning Central Air Conditioning Central Air Conditioning May 30, 2012 - 8:01pm Addthis Central air conditioners circulate cool air through a system of supply and return ducts. | Photo courtesy of テつゥiStockphoto/DonNichols. Central air conditioners circulate cool air through a system of supply and return ducts. | Photo courtesy of ツゥiStockphoto/DonNichols. What does this mean for me? Central air conditioning systems are thermostatically controlled and convenient to use. Central air conditioning systems must be installed properly to operate efficiently. Central air conditioning systems can share ductwork with your heating system. Central air conditioners circulate cool air through a system of supply and return ducts. Supply ducts and registers (i.e., openings in the walls,

191

Zoned heating and air conditioning system  

SciTech Connect

This patent describes a zoned heating and air conditioning system comprising: a central air handling system with an air heating means and an air cooling means and a blower connected to an air duct system; thermostats each have heating and cooling set points, respectively associated with and located in different zones of a building; dampers respectively associated with each building zone positioned in the air duct system. Each damper has an open position allowing air into the respective zone from the duct system and a closed position; relay means for connecting one thermostat to the air handling system upon a call for heating or cooling by one thermostat and disconnecting all other thermostats by connecting one thermostat's connections between the thermostat and air handling system. Only one thermostat is connected to the air handling system at a time and the relay means disconnects one thermostat from the air handling system after one thermostat is satisified; and damper actuating means for unlocking each damper in one building zone responsive actuated by a respective zone thermostat connected to the air handling system by the relay means. The damper actuates means including a damper solenoid for each damper located adjacent each damper and connected to a respective zone thermostat. It unlocks each damper in one building zone responsive to being actuated by the respective zone thermostat and unlocks the dampers in one building zone when one thermostat is actuated while preventing the dampers in another thermostat's building zone from unlocking.

Beachboard, S.A.

1987-06-16T23:59:59.000Z

192

Energy Basics: Solar Air Heating  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Homes & Buildings Printable Version Share this resource Lighting & Daylighting Passive Solar Design Space Heating & Cooling Cooling Systems Heating Systems Furnaces & Boilers Wood...

193

Rotating heat pipe for air-conditioning  

SciTech Connect

A unique rotary hermetic heat pipe is disclosed for transferring heat from an external source to an external heat sink. The heat pipe has a tapered condensing surface which is curved preferably to provide uniform pumping acceleration, the heat pipe being rotated at a velocity such that the component of centrifugal acceleration in an axial direction parallel to the tapered surface is greater than lG and so that the condensing surface is kept relatively free of liquid at any attitude. The heat pipe may be incorporated in an air conditioning apparatus so that it projects through a small wall opening. In the preferred air conditioning apparatus, a hollow hermetic air impeller is provided which contains a liquefied gaseous refrigerant, such as freon, and means are provided for compressing the refrigerant in the evaporator region of the heat pipe.

Gray, V.H.

1976-12-28T23:59:59.000Z

194

Experimental study of a R-407C drop-in test on an off-the-shelf air conditioner with a counter-cross-flow evaporator  

SciTech Connect

An off-the-shelf 2-ton window air conditioner having an energy efficiency ratio of 10 was used to perform a drop-in test with R-407C. Laboratory tests were performed using a parallel-cross-flow (PCF) evaporator and a counter-cross-flow (CCF) evaporator. The CCF configuration is designed to take advantage of the temperature glide of R-407C so that the warm evaporator inlet air will be in contact with the higher temperature part of the evaporator coils first. The test results indicated that, at the Air Conditioning and Refrigeration Institute-rated indoor and outdoor conditions, the cooling capacity was 8% higher and system coefficient of performance about 3.8% higher for the CCF evaporator than for the PCF evaporator. The test results also showed that the latent load for CCF was 30.6% higher than for PCF. The far better dehumidification effect provided by the CCF evaporator design is desirable for areas where the latent load is high. The experimental findings should be useful for future efforts to design a dehumidifier that uses a zeotropic refrigerant that provides a significant temperature glide. R-22 test data from a previous project are included as a reference.

Mei, V.C.; Domitrovic, R.; Chen, F.C.

1998-03-01T23:59:59.000Z

195

Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pumps Heat Pumps Heat Pumps Geothermal heat pumps are expensive to install but pay for themselves over time in reduced heating and cooling costs. Learn more about how geothermal heat pumps heat and cool buildings by concentrating the naturally existing heat contained within the earth -- a clean, reliable, and renewable source of energy. In moderate climates, heat pumps can be an energy-efficient alternative to furnaces and air conditioners. Several types of heat pumps are available, including air-source; geothermal; ductless, mini-split; and absorption heat pumps. Learn more about the different options and how to use your heat pump efficiently to save money and energy at home. Featured Heat Pump Systems A heat pump can provide an alternative to using your air conditioner. | Photo courtesy of iStockPhoto/LordRunar.

196

FEMP--Geothermal Heat Pumps  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

heat pump-like an air conditioner or refrigera- heat pump-like an air conditioner or refrigera- tor-moves heat from one place to another. In the summer, a geothermal heat pump (GHP) operating in a cooling mode lowers indoor temperatures by transferring heat from inside a building to the ground outside or below it. Unlike an air condition- er, though, a heat pump's process can be reversed. In the winter, a GHP extracts heat from the ground and transfers it inside. Also, the GHP can use waste heat from summer air-conditioning to provide virtually free hot-water heating. The energy value of the heat moved is typically more than three times the electricity used in the transfer process. GHPs are efficient and require no backup heat because the earth stays at a relatively moderate temperature throughout the year.

197

Ground Source Heat Pump Air Conditioner Monitoring Control System Design Based on CAN Bus  

Science Conference Proceedings (OSTI)

Based on CAN bus technology, chooses ST's ARM Cortex-M3 core, new generation STM32 embedded enhanced processor STM32F103 as main control chip, designs the overall structure of system, CAN functional block diagram, CAN communication software and so on. ... Keywords: CAN bus embedded STM32F103

Tong Gang; Li Ping

2010-06-01T23:59:59.000Z

198

heat pump | OpenEI  

Open Energy Info (EERE)

heat pump heat pump Dataset Summary Description View 2010 energy efficiency data from AeroSys Inc, Coaire, Cold Point, First Operations, LG Electronics, Nordyne, and Quietside manufacturers. Data includes cooling capacity, cooling performance, heating capacity, and heating performance. Spreadsheet was created by combining the tables in pdf files that are included in the zip file. Source Energy Applicance Data - United States Federal Trade Commission, www.ftc.gov Date Released Unknown Date Updated Unknown Keywords air conditioner central air conditioner efficiency efficient energy heat pump Data application/vnd.ms-excel icon 2010_CentralAC_All.xls (xls, 82.4 KiB) application/zip icon 2010CentralAirConditioner.zip (zip, 398.2 KiB) Quality Metrics Level of Review Some Review

199

Solar-Powered, Liquid-Desiccant Air Conditioner for Low-Electricity Humidity Control: Report and Summary Report  

DOE Green Energy (OSTI)

The primary objective of this project was to demonstrate the capabilities of a new high-performance, liquid-desiccant dedicated outdoor air system (DOAS) to enhance cooling efficiency and comfort in humid climates while substantially reducing electric peak demand at Tyndall Air Force Base (AFB), which is 12 miles east of Panama City, Florida.

Dean, J.; Kozubal, E.; Herrmann, L.; Miller, J.; Lowenstein, A.; Barker, G.; Slayzak, S.

2012-11-01T23:59:59.000Z

200

Research on Convective Heat Transfer and Mass Transfer of the Evaporator in Micro/Mini-Channel  

E-Print Network (OSTI)

With the development of science and technology, various heating and cooling equipment have a development trend of micromation. Micro-fabrication processes make it possible to conduct research on condensation heat transfer in micro-channels. Based on the reviewers on the present household air conditioners, the potential requirements for new heat transfer enhancement used for household air conditioners are discussed. Investigations on condensation and boiling of refrigerants in mini/micro channels have indicated that the evaporator and condenser of air conditioner would be more efficient and more compact by using microchannels, and hence it could improve the coefficient of performance of air conditioners to meet the new energy conversion standards in China. The relationship between condensation heat transfer of refrigerants and surface physical characteristics of the evaporator are pointed out and analyzed in order to achieving the corresponding heat transfer coefficients.

Su, J.; Li, J.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976  

E-Print Network (OSTI)

cooled, ammonia-water absorption chiller as a starting pointabsorption cycle under such conJitions. A nominal three-ton,continuous operation, heat-actuated water chiller

Dao, K.

2010-01-01T23:59:59.000Z

202

Candidate chemical systems for air cooled, solar powered, absorption air conditioner design. Part III. Lithium salts with anti-freeze additives  

DOE Green Energy (OSTI)

The two most promising anti-solidification additives which have been identified are ethanolamine and ethylene glycol. Considerations of viscosity, corrosion, crystallization temperature and vapor pressure have led to a selection of lithium bromide - ethylene glycol - water as the basis of a prototype air-cooled machine, with the lithium bromide; ethylene glycol ratio being 4.5. Using what appear to be reasonable heat exchanger approach temperatures, cycle thermal COP's of 0.7/sup +/ appear possible at the specified design point, based on solution properties which were determined with qualification accuracy. The prototype, delivering 10,000 watts of cooling, has a calculated parasitical electrical load of about 175 watts (theoretical) to drive the internal fans and pumps, equivalent to about a 0.5 horsepower motor.

Biermann, W.J.

1978-06-01T23:59:59.000Z

203

Simulation model air-to-air plate heat exchanger  

Science Conference Proceedings (OSTI)

A simple simulation model of an air-to-air plate heat exchanger is presented. The model belongs to a collection of simulation models that allows the eflcient computer simulation of heating, ventilation, and air-conditioning (HVAC) systems. The main emphasis of the models is to shorten computation time and to use only input data that are known in the design process of an HVAC system. The target of the models is to describe the behavior of HVAC components in the part-load operation mode, which is becoming increasingly important in energy eficient HVAC systems. The models are intended to be used for yearly energy calculations or load calculations with time steps of about 10 minutes or larger. Short- time dynamic effects, which are of interest for different aspects of control theory, are neglected. The part-load behavior is expressed in terms of the nominal condition and the dimensionless variation of the heat transfer with change of mass flow and temperature. The effectiveness- NTU relations are used to parametrize the convective heat transfer at nominal conditions and to compute the part-load condition. If the heat transfer coefficients on the two exchanger sides are not equal (i. e. due to partial bypassing of air), their ratio can be easily calculated and set as a parameter. The model is static and uses explicit equations only. The explicit model formulation ensures short computation time and numerical stability, which allows using the model with sophisticated engineering methods like automatic system optimization. This paper fully outlines the algorithm description and its simplifications. It is not tailored for any particular simulation program to ensure easy implementation in any simulation program.

Wetter, Michael

1999-01-01T23:59:59.000Z

204

Heating, ventilation and air conditioning systems  

DOE Green Energy (OSTI)

A study is made of several outstanding issues concerning the commercial development of environmental control systems for electric vehicles (EVs). Engineering design constraints such as federal regulations and consumer requirements are first identified. Next, heating and cooling loads in a sample automobile are calculated using a computer model available from the literature. The heating and cooling loads are then used as a basis for estimating the electrical consumption that is to be expected for heat pumps installed in EVs. The heat pump performance is evaluated using an automobile heat pump computer model which has been developed recently at Oak Ridge National Laboratory (ORNL). The heat pump design used as input to the model consists of typical finned-tube heat exchangers and a hermetic compressor driven by a variable-speed brushless dc motor. The simulations suggest that to attain reasonable system efficiencies, the interior heat exchangers that are currently installed as automobile air conditioning will need to be enlarged. Regarding the thermal envelope of the automobile itself, calculations are made which show that considerable energy savings will result if steps are taken to reduce {open_quote}hot soak{close_quote} temperatures and if the outdoor air ventilation rate is well controlled. When these changes are made, heating and cooling should consume less than 10% of the total stored electrical energy for steady driving in most U.S. climates. However, this result depends strongly upon the type of driving: The fraction of total power for heating and cooling ({open_quote}range penalty{close_quote}) increases sharply for driving scenarios having low average propulsion power, such as stop-and-go driving.

Kyle, D.M. [Oak Ridge National Lab., TN (United States); Sullivan, R.A. [Dept. of Energy, Washington, DC (United States)

1993-02-01T23:59:59.000Z

205

NREL Demonstrates Game-Changing Air Conditioner Technology (Fact Sheet), Highlights in Research & Development, NREL (National Renewable Energy Laboratory)  

NLE Websites -- All DOE Office Websites (Extended Search)

Testing of DEVAP prototype validates modeled Testing of DEVAP prototype validates modeled predictions of 40% to 85% energy savings. Researchers in the NREL Buildings group are moving the award-winning desiccant enhanced evaporative (DEVAP) air conditioning technol- ogy further toward commercialization by demonstrating that its energy-saving perfor- mance matches closely with thermodynamic model predictions. Industry partners Synapse Product Development and AIL Research built two prototypes of DEVAP based on NREL's design and modeling, which were tested in NREL's Advanced HVAC Systems Laboratory. Experiments added confidence to the predicted energy savings of 40% in humid climates and 85% in dry climates, empowering the model as a tool for developing marketable designs, and illustrating the potential of DEVAP to transform

206

Empirical Modeling of a Rolling-Piston Compressor Heat Pump for Predictive Control in Low-Lift Cooling  

E-Print Network (OSTI)

Inverter-driven variable-capacity air conditioners, heat pumps, and chillers can provide energy-efficient cooling, particularly at part-load capacity. Varying the capacity of vapor compression systems enables operation at ...

Gayeski, Nicholas

207

Memorandum To: GENERAL COUNSEL, DEPARTMENT OF ENERGY (DOE) From: JONATHAN MELCHI, HEATING, AIR-CONDITIONING AND REFRIGERATION  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

To: GENERAL COUNSEL, DEPARTMENT OF ENERGY (DOE) To: GENERAL COUNSEL, DEPARTMENT OF ENERGY (DOE) From: JONATHAN MELCHI, HEATING, AIR-CONDITIONING AND REFRIGERATION DISTRIBUTORS INTERNATIONAL (HARDI) Date: 1/12/2012 Subject: EX PARTE COMMUNICATION MEMO DOE ATTENDEES: Ashley Armstrong, John Cymbalsky, David Case, Laura Barhydt HARDI ATTENDEES: Talbot Gee, Jonathan Melchi AREAS OF DISCUSSION: DOE Framework Document and Stakeholder Meeting regarding the Enforcement of the updated Energy Conservation Standards for Air Conditioners, Furnaces and Heat Pumps. The meeting took place on Thursday January 5 th , 2012 from 2pm to 3-pm. The following topics were discussed. 1.) Sell-Through. HARDI asked for clarification on the DOE's notation on the Framework Document

208

Air-Source Heat Pump Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air-Source Heat Pump Basics Air-Source Heat Pump Basics Air-Source Heat Pump Basics August 19, 2013 - 11:03am Addthis Air-source heat pumps transfer heat between the inside of a building and the outside air. How Air-Source Heat Pumps Work This diagram of a split-system heat pump heating cycle shows refrigerant circulating through a closed loop that passes through the wall of a house. Inside the house the refrigerant winds through indoor coils, with a fan blowing across them, and outside the house is another fan and another set of coils, the outdoor coils. A compressor is between the coils on one half of the loop, and an expansion valve is between the coils on the other half. The diagram is explained in the caption. In heating mode, an air-source heat pump evaporates a refrigerant in the outdoor coil; as the liquid evaporates it pulls

209

HVAC Radial Air Bearing Heat Exchangers Research Project | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radial Air Bearing Heat Exchangers Radial Air Bearing Heat Exchangers Research Project HVAC Radial Air Bearing Heat Exchangers Research Project The U.S. Department of Energy is currently conducting research into heating, ventilation, and air conditioning (HVAC) radial air bearing heat exchangers. Rotary air bearing heat exchanger technology simultaneously solves four long standing problems of conventional "fan-plus-finned-heat-sink" heat exchangers. Project Description This project seeks to design, fabricate, and test successive generations of prototype radial air bearing heat exchanger devices based on lessons learned and further insights into device optimization, computational fluid dynamic studies for parametric optimization and determination of scaling laws, and laboratory measurement of flow field and heat transfer

210

Air-Conditioning, Heating, and Refrigeration Institute (AHRI...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI These comments...

211

Investigation on a Microwave High-Temperature Air Heat Exchanger  

Science Conference Proceedings (OSTI)

In present paper, an energy efficient air heat exchanger, based on accumulation of the heat generated by microwave absorbing materials is presented according ...

212

Heating, Ventilation, and Air Conditioning Renovations | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heating, Ventilation, and Air Conditioning Renovations Heating, Ventilation, and Air Conditioning Renovations Heating, Ventilation, and Air Conditioning Renovations October 16, 2013 - 4:49pm Addthis Renewable Energy Options for HVAC Renovations Geothermal Heat Pumps (GHP) Solar Water Heating (SWH) Biomass Passive Solar Heating Biomass Heating Solar Ventilation Air Preheating Federal building renovations that encompass the heating, ventilation, and air conditioning (HVAC) systems in a facility provide a range of renewable energy opportunities. The primary technology option for HVAC renovations is geothermal heat pumps (GHP). Other options include leveraging a solar water heating (SWH) system to offset heating load or using passive solar heating or a biomass-capable furnace or boiler. Some facilities may also take

213

Building Technologies Office: Air-Source Integrated Heat Pump Research  

NLE Websites -- All DOE Office Websites (Extended Search)

Air-Source Integrated Air-Source Integrated Heat Pump Research Project to someone by E-mail Share Building Technologies Office: Air-Source Integrated Heat Pump Research Project on Facebook Tweet about Building Technologies Office: Air-Source Integrated Heat Pump Research Project on Twitter Bookmark Building Technologies Office: Air-Source Integrated Heat Pump Research Project on Google Bookmark Building Technologies Office: Air-Source Integrated Heat Pump Research Project on Delicious Rank Building Technologies Office: Air-Source Integrated Heat Pump Research Project on Digg Find More places to share Building Technologies Office: Air-Source Integrated Heat Pump Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research

214

Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger  

NLE Websites -- All DOE Office Websites (Extended Search)

Radial Air Bearing Radial Air Bearing Heat Exchanger Research Project to someone by E-mail Share Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Facebook Tweet about Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Twitter Bookmark Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Google Bookmark Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Delicious Rank Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Digg Find More places to share Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE

215

Air-Source Heat Pump Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Source Heat Pump Basics Source Heat Pump Basics Air-Source Heat Pump Basics August 19, 2013 - 11:03am Addthis Air-source heat pumps transfer heat between the inside of a building and the outside air. How Air-Source Heat Pumps Work This diagram of a split-system heat pump heating cycle shows refrigerant circulating through a closed loop that passes through the wall of a house. Inside the house the refrigerant winds through indoor coils, with a fan blowing across them, and outside the house is another fan and another set of coils, the outdoor coils. A compressor is between the coils on one half of the loop, and an expansion valve is between the coils on the other half. The diagram is explained in the caption. In heating mode, an air-source heat pump evaporates a refrigerant in the outdoor coil; as the liquid evaporates it pulls

216

Air Conditioning with Magnetic Refrigeration : An Efficient, Green Compact Cooling System Using Magnetic Refrigeration  

SciTech Connect

BEETIT Project: Astronautics is developing an air conditioning system that relies on magnetic fields. Typical air conditioners use vapor compression to cool air. Vapor compression uses a liquid refrigerant to circulate within the air conditioner, absorb the heat, and pump the heat out into the external environment. Astronautics design uses a novel property of certain materials, called 杜agnetocaloric materials, to achieve the same result as liquid refrigerants. These magnetocaloric materials essentially heat up when placed within a magnetic field and cool down when removed, effectively pumping heat out from a cooler to warmer environment. In addition, magnetic refrigeration uses no ozone-depleting gases and is safer to use than conventional air conditioners which are prone to leaks.

None

2010-09-01T23:59:59.000Z

217

Solar assisted heat pump on air collectors: A simulation tool  

Science Conference Proceedings (OSTI)

The heating system of the bioclimatic building of the Greek National Centre for Renewable Energy Sources (CRES) comprises two heating plants: the first one includes an air source heat pump, Solar Air Collectors (SACs) and a heat distribution system (comprising a fan coil unit network); the second one is, mainly, a geothermal heat pump unit to cover the ground floor thermal needs. The SAC configuration as well as the fraction of the building heating load covered by the heating plant are assessed in two operation modes; the direct (hot air from the collectors is supplied directly to the heated space) and the indirect mode (warm air from the SAC or its mixture with ambient air is not supplied directly to the heated space but indirectly into the evaporator of the air source heat pump). The technique of the indirect mode of heating aims at maximizing the efficiency of the SAC, saving electrical power consumed by the compressor of the heat pump, and therefore, at optimizing the coefficient of performance (COP) of the heat pump due to the increased intake of ambient thermal energy by means of the SAC. Results are given for three research objectives: assessment of the heat pump efficiency whether in direct or indirect heating mode; Assessment of the overall heating plant efficiency on a daily or hourly basis; Assessment of the credibility of the suggested simulation model TSAGAIR by comparing its results with the TRNSYS ones. (author)

Karagiorgas, Michalis; Galatis, Kostas; Tsagouri, Manolis [Department of Mechanical Engineering Educators, ASPETE, N. Iraklio, GR 14121 (Greece); Tsoutsos, Theocharis [Environmental Engineering Dept., Technical University of Crete, Technical University Campus, GR 73100, Chania (Greece); Botzios-Valaskakis, Aristotelis [Centre for Renewable Energy Sources (CRES), 19th km Marathon Ave., GR 19001, Pikermi (Greece)

2010-01-15T23:59:59.000Z

218

Air-Source Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air-Source Heat Pumps Air-Source Heat Pumps Air-Source Heat Pumps June 24, 2012 - 3:35pm Addthis When properly installed, an air-source heat pump can deliver one-and-a-half to three times more heat energy to a home than the electrical energy it consumes. | Photo courtesy of iStockPhoto/YinYang. When properly installed, an air-source heat pump can deliver one-and-a-half to three times more heat energy to a home than the electrical energy it consumes. | Photo courtesy of iStockPhoto/YinYang. What does this mean for me? If you live in a cooling climate, an air-source heat pump is a good choice. If you live in a heating climate, watch for advanced air-source heat pumps coming on the market that operate well in sub-freezing temperatures. An air-source heat pump can provide efficient heating and cooling for your

219

Air source heat pump system for drying application  

Science Conference Proceedings (OSTI)

This paper investigates the performance of an air source heat pump for drying purpose. In order to evaluate the performance analysis; a simulation study has been done. The results of simulation of heat pump dryer for different evaporator temperatures ... Keywords: air source heat pump, coefficient of performance (COP), condenser temperature and compressor work, dryer, evaporator temperature

R. Daghigh; M. H. Ruslan; A. Zaharim; K. Sopian

2010-10-01T23:59:59.000Z

220

Automobile air-conditioning unit. Final report  

SciTech Connect

In this study the refrigerant in the automobile air-conditioner is compressed by thermal energy in a unique compression system rather than by work in a standard compressor. The compression uses an intermittent compression process with a solid absorbent. The vapor is absorbed by an absorbent at relatively low temperature and ejected as the absorbent temperature is raised. A set of one way valves limits flow to one direction. Major contributions are heat transfer requirements, molecular sieve-refrigerant matching, minimizing non-producing mass, solving thermal fatigue and shock problems, and applying this to automobile air-conditioning. The performance study shows energy savings up to fifty percent are possible, depending on engine load. A twenty percent energy savings with the vehicle tested with the air-conditioner in operation is average. The study also showed that less fuel is used with the windows open than with the air-conditioner operating.

Schaetzle, W.J.

1982-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Heat Pump System Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pump System Basics Heat Pump System Basics Heat Pump System Basics August 19, 2013 - 11:02am Addthis Like a refrigerator, heat pumps use electricity to move heat from a cool space into a warm space, making the cool space cooler and the warm space warmer. Because they move heat rather than generate heat, heat pumps can provide up to four times the amount of energy they consume. Air-Source Heat Pump Transfers heat between the inside of a building and the outside air. Ductless Mini-Split Heat Pump Ductless versions of air-source heat pumps. Absorption Heat Pump Uses heat as its energy source. Geothermal Heat Pumps Use the constant temperature of the earth as the exchange medium instead of the outside air temperature. Addthis Related Articles A heat pump can provide an alternative to using your air conditioner. | Photo courtesy of iStockPhoto/LordRunar.

222

Wabash County REMC - Residential Geothermal and Air-source Heat...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Other Agencies You are here Home Savings Wabash County REMC - Residential Geothermal and Air-source Heat Pump Rebate Program Wabash County REMC - Residential Geothermal...

223

Kosciusko REMC - Residential Geothermal and Air-source Heat Pump...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Other Agencies You are here Home Savings Kosciusko REMC - Residential Geothermal and Air-source Heat Pump Rebate Program Kosciusko REMC - Residential Geothermal and...

224

New and Underutilized Heating, Ventilation, and Air Conditioning...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8, 2013 - 2:56pm Addthis The following heating, ventilation, and air conditioning (HVAC) technologies are underutilized within the Federal sector. These technologies have been...

225

Heat transfer and condensation of water vapour from humid air in compact heat exchangers.  

E-Print Network (OSTI)

??In this thesis, an experimental and simulation study of heat transfer in water-to-air compact-plate heat exchanger is presented. A compact-plate heat exchanger made of polypropylene, (more)

Saraireh, Mohammad

2012-01-01T23:59:59.000Z

226

An Analysis of Price Determination and Markups in the Air-Conditioning and Heating Equipment Industry  

E-Print Network (OSTI)

of Commercial and Residential Air Conditioning and HeatingOF COMMERCIAL AND RESIDENTIAL AIR-CONDITIONING AND HEATINGand residential air-conditioning and heating equipment.

2004-01-01T23:59:59.000Z

227

A Homeownerツ尽 Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet), Building America Case Study: Technology Solutions for Existing Homes, Building Technologies Office (BTO)  

NLE Websites -- All DOE Office Websites (Extended Search)

Homeowners in the United States spend Homeowners in the United States spend one out of every eight dollars of utility costs on cooling their living space. Window air conditioners (A/Cs) are an inexpensive alternative to central systems, and are sold in greater numbers each year than all other residential cooling systems. They are purchased to cool a specific room and are easy for anyone to install. In contrast to these benefits, window A/Cs come at a cost-they operate less efficiently (using more energy to do the same cooling) than most other residential A/C systems. Researchers at the National Renewable Energy Laboratory (NREL) studied window A/Cs on behalf of the U.S.

228

Tips: Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pumps Heat Pumps Tips: Heat Pumps June 24, 2013 - 5:48pm Addthis Heat pumps can be a cost-effective choice in moderate climates, especially if you heat your home with electricity. Heat pumps can be a cost-effective choice in moderate climates, especially if you heat your home with electricity. Heat pumps are the most efficient form of electric heating in moderate climates. Because they move heat rather than generate heat, heat pumps can provide equivalent space conditioning at as little as one quarter of the cost of operating conventional heating or cooling appliances. A heat pump does double duty as a central air conditioner by collecting the heat inside your house and pumping it outside. There are three types of heat pumps: air-to-air, water source, and geothermal. They collect heat from the air, water, or ground outside your

229

Solar-powered saline sorbent-solution heat pump/storage system. [Coastal Energy Laboratory-Chemical Heat Pump (CEL-CHEAP)  

SciTech Connect

Coastal Energy Laboratory Chemical Heat Pump (CEL-CHEAP) is a redesigned open-cycle liquid desiccant air conditioner. Heat is discharged to shallow-well water by dehumidification-humidification for cooling and extracted by humidification-dehumidification for heating. Direct solar radiation concentrates the desiccant. For continuous operation, a small uninsulated tank stores concentrated solution. 6 refs.

Robison, H.; Houston, S.

1981-01-01T23:59:59.000Z

230

Energy Efficiency Supporting Policy and Heat Pumping Technology in Japan  

E-Print Network (OSTI)

(U.S. dollars) is calculated with Japan = 1. #12;2-1. Eco Cute : example of countermeasure for energy feature Counter flow Heat exchanger Heat pump unit Storage tank Ref: TEPCO Website Ref: HPTCJ HP Space in Residential sector (FY2009) e.g. Gas stove e.g. Air- conditioner e.g. Domestic water heater e.g. lighting PC

Oak Ridge National Laboratory

231

Performance comparison between air and liquid residential solar heating systems  

SciTech Connect

Comparisons of system performance for the flat plate liquid-heating system in CSU Solar House I, the evacuated-tube collector system in Solar House I, and the flat plate air-heating system in CSU Solar House II are described for selected months of the 1976 and 1977 heating seasons. Only space and domestic water heating data are compared. The flat plate air- and liquid-heating collectors operating with complete heating systems have nearly equal efficiencies when based upon solar flux while the collector fluids are flowing, but approximately 40% more energy is collected during a heating season with the air-heating system because the air system operates over a longer period of the day. On the basis of short-term data, the evacuated tube collector array on Solar House I is about 27% more efficient than the flat plate air-heating collector array on Solar House II based on gross roof area occupied by the collectors and manifolds.

Karaki, S.; Duff, W.S.; Loef, G.O.G.

1978-01-01T23:59:59.000Z

232

Energy Basics: Air-Source Heat Pumps  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

from ductwork that protrudes through a wall or roof. More Information Visit the Energy Saver website for more information about the selection and performance of air-source...

233

Going Ductless with Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Going Ductless with Heat Pumps Going Ductless with Heat Pumps Going Ductless with Heat Pumps November 2, 2009 - 9:06am Addthis John Lippert My home, unlike most homes in the United States, has no ducts. My wife and I bought the house nearly 20 years ago. Window air conditioners provided air conditioning during the hot muggy Washington, D.C., summers. Baseboard electric heaters provided heating in winter. Before a lot of you post your sympathies in the comments, let me say this: my house is well insulated and very air tight, as a whole house energy audit demonstrated about 15 years ago. Yet, even though electric baseboard heating is about 100% efficient, it is a costly way of heating a house. And as I got older, each year I enjoyed installing and removing the window air conditioners less and less.

234

DOE Institutes Enforcement Action Against AeroSys, Inc. for Failure to Certify Air Conditioners and Heat Pumps  

Energy.gov (U.S. Department of Energy (DOE))

Washington, DC - The Department of Energy痴 Office of General Counsel has issued a Notice of Proposed Civil Penalty to AeroSys, Inc. for failing to file certification reports or filing data that...

235

Self-defrosting recuperative air-to-air heat exchanger  

DOE Patents (OSTI)

A heat exchanger includes a stationary spirally or concentrically wound heat exchanger core with rotating baffles on upper and lower ends thereof. The rotating baffles include rotating inlets and outlets which are in communication with respective fixed inlets and outlets via annuli. The rotation of the baffles causes a concurrent rotation of the temperature distribution within the stationary exchanger core, thereby preventing frost build-up in some applications and preventing the formation of hot spots in other applications.

Drake, Richard L. (Delmar, NY)

1993-01-01T23:59:59.000Z

236

Intelligent Control of Heating, Ventilating and Air Conditioning Systems  

Science Conference Proceedings (OSTI)

This paper proposed a simulation-optimization energy saving strategy for heating, ventilating and air conditioning (HVAC) systems' condenser water loop through intelligent control of single speed cooling towers' components. An analysis of system components ...

Patrick Low Kie; Lau Bee Theng

2009-07-01T23:59:59.000Z

237

Development of a Dedicated 100 Percent Ventilation Air Heat Pump  

Science Conference Proceedings (OSTI)

The concept of using dedicated 100 percent ventilation makeup air conditioning units to meet indoor air quality standards is attractive because of the inherent advantages. However, it is challenging to design and build direct expansion unitary equipment for this purpose. EPRI teamed with ClimateMaster to develop and test a prototype of a vapor compression heat pump to advance the state of the art in such equipment. The prototype unit provides deep dehumidification and cooling of ventilation air in the su...

2000-12-14T23:59:59.000Z

238

Homeowner's Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet), Building America Case Study: Technology Solutions for Existing Homes, Building Technologies Office (BTO)  

SciTech Connect

This fact sheet offers a step-by-step guide to proper installation of window air conditioning units, in order to improve efficiency and comfort for homeowners.

Not Available

2013-06-01T23:59:59.000Z

239

Global warming impacts of ozone-safe refrigerants and refrigeration, heating, and air-conditioning technologies  

SciTech Connect

International agreements mandate the phase-out of many chlorine containing compounds that are used as the working fluid in refrigeration, air-conditioning, and heating equipment. Many of the chemical compounds that have been proposed, and are being used in place of the class of refrigerants eliminated by the Montreal Protocol are now being questioned because of their possible contributions to global warming. Natural refrigerants are put forth as inherently superior to manufactured refrigerants because they have very low or zero global warming potentials (GWPs). Questions are being raised about whether or not these manufactured refrigerants, primarily hydrofluorocarbons (HFCs), should be regulated and perhaps phased out in much the same manner as CFCs and HCFCs. Several of the major applications of refrigerants are examined in this paper and the results of an analysis of their contributions to greenhouse warming are presented. Supermarket refrigeration is shown to be an application where alternative technologies have the potential to reduce emissions of greenhouse gases (GHG) significantly with no clear advantage to either natural or HFC refrigerants. Mixed results are presented for automobile air conditioners with opportunities to reduce GHG emissions dependent on climate and comfort criteria. GHG emissions for hermetic and factory built systems (i.e. household refrigerators/freezers, unitary equipment, chillers) are shown to be dominated by energy use with much greater potential for reduction through efficiency improvements than by selection of refrigerant. The results for refrigerators also illustrate that hydrocarbon and carbon dioxide blown foam insulation have lower overall effects on GHG emissions than HFC blown foams at the cost of increased energy use.

Fischer, S.; Sand, J.; Baxter, V.

1997-12-01T23:59:59.000Z

240

Electric equipment providing space conditioning, water heating, and refrigeration consumes 12.5% of the nation's  

E-Print Network (OSTI)

-acceptable refrigerants. Whether involving design of specific new products or refriger- ants to which the entire industryElectric equipment providing space conditioning, water heating, and refrigeration consumes 12 are the heart of air conditioners, heat pumps, chillers, supermarket refrigeration systems, and more. Global use

Oak Ridge National Laboratory

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Commercial Air-Source Heat Pumps, Purchasing Specifications for Energy-Efficient Products (Fact Sheet)  

SciTech Connect

Energy efficiency purchasing specifications for federal procurements of commercial air-source heat pumps.

Not Available

2011-02-11T23:59:59.000Z

242

Performance Analysis of Air-Source Variable Speed Heat Pumps and Various Electric Water Heating Options  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Analysis of Air- Analysis of Air- Source Variable Speed Heat Pumps and Various Electric Water Heating Options Jeffrey Munk Oak Ridge National Laboratory 2 Managed by UT-Battelle for the U.S. Department of Energy Presentation_name Acknowledgements * Tennessee Valley Authority - David Dinse * U.S. Department of Energy * Roderick Jackson * Tony Gehl * Philip Boudreaux * ZEBRAlliance 3 Managed by UT-Battelle for the U.S. Department of Energy Presentation_name Overview * Electric Water Heating Options - Conventional Electric Water Heaters - Heat Pump Water Heaters * Air-Source * Ground-Source - Solar Thermal Water Heater * Variable Speed Heat Pumps - Energy Use Analysis - Measured Performance - Operational Characteristics 4 Managed by UT-Battelle for the U.S. Department of Energy Presentation_name Water Heating Options

243

Federal Energy Management Program: Covered Product Category: Room Air  

NLE Websites -- All DOE Office Websites (Extended Search)

Room Air Conditioners to someone by E-mail Room Air Conditioners to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Facebook Tweet about Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Twitter Bookmark Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Google Bookmark Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Delicious Rank Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Digg Find More places to share Federal Energy Management Program: Covered Product Category: Room Air Conditioners on AddThis.com... Energy-Efficient Products Federal Requirements Covered Product Categories Product Designation Process

244

Experimental Research of Air Source Heat Pump Frosting and Defrosting in a Double Stage-Coupling Heat Pump  

E-Print Network (OSTI)

In a double stage-coupling heat pump, comprising an air source and water loop heat pump, the 13~20 ? low temperature water is supplied to the water loop heat pump unit. The water loop heat pump can extract heat from the water and heat the indoor air. The most common method of air source heat pump frost removal is reverse-cycle defrost. During the defrosting operation, the heat pump runs in the cooling mode. The defrost process is accomplished by reversing the normal heating mode. In this paper, the effect of the heat storage tank to the air source heat pump defrosting is test. Owing to the existence of the heat storage tank, thermal inertia of the loop is relatively high. The frosting and defrosting course of the air source heat pump have little effect on the room temperature.

Wang, Z.; Gu, J.; Lu, Z.

2006-01-01T23:59:59.000Z

245

The effects of outdoor heat exchanger hydrophobic treatment on the performance of an air source heat pump.  

E-Print Network (OSTI)

??The effects of outdoor heat exchanger hydrophobic treatment on the performance of an air source heat pump were investigated. The base case tests used a (more)

Parker, Brandon DeWayne

2012-01-01T23:59:59.000Z

246

Duct Systems in large commercial buildings: Physical characterization, air leakage, and heat conduction gains  

E-Print Network (OSTI)

Air Leakage, and Heat Conduction Gains William 1. Fisk,0.75 to 0.90; thus, heat conduction decreased the coolingby air leakage or heat conduction, because these ducts are

Fisk, W.J.

2011-01-01T23:59:59.000Z

247

Advanced Variable Speed Air-Source Integrated Heat Pump  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

variable speed air-source variable speed air-source integrated heat pump (AS-IHP) - CRADA Van D. Baxter Oak Ridge National Laboratory vdb@ornl.gov; 865-574-2104 April 3, 2013 Development of advanced HVAC/WH system options for efficient residential or small commercial buildings, new const. or retrofit * ET R&D project in support of DOE/BTO Goal of 50% Reduction in Building Energy Use by 2030 IHP concept - all HVAC & WH services integrated into

248

Advanced Variable Speed Air-Source Integrated Heat Pump  

NLE Websites -- All DOE Office Websites (Extended Search)

variable speed air-source variable speed air-source integrated heat pump (AS-IHP) - CRADA Van D. Baxter Oak Ridge National Laboratory vdb@ornl.gov; 865-574-2104 April 3, 2013 Development of advanced HVAC/WH system options for efficient residential or small commercial buildings, new const. or retrofit * ET R&D project in support of DOE/BTO Goal of 50% Reduction in Building Energy Use by 2030 IHP concept - all HVAC & WH services integrated into

249

Buildings Energy Data Book: 5.3 Heating, Cooling, and Ventilation Equipment  

Buildings Energy Data Book (EERE)

2 2 Main Commercial Heating and Cooling Equipment as of 1995, 1999, and 2003 (Percent of Total Floorspace) (1) Heating Equipment 1995 1999 2003 (2) Cooling Equipment 1995 1999 2003 (2) Packaged Heating Units 29% 38% 28% Packaged Air Conditioning Units 45% 54% 46% Boilers 29% 29% 32% Individual Air Conditioners 21% 21% 19% Individual Space Heaters 29% 26% 19% Central Chillers 19% 19% 18% Furnaces 25% 21% 30% Residential Central Air Conditioners 16% 12% 17% Heat Pumps 10% 13% 14% Heat Pumps 12% 14% 14% District Heat 10% 8% 8% District Chilled Water 4% 4% 4% Other 11% 6% 5% Swamp Coolers 4% 3% 2% Other 2% 2% 2% Note(s): Source(s): 1) Heating and cooling equipment percentages of floorspace total more than 100% since equipment shares floorspace. 2) Malls are no longer included in most CBECs tables; therefore, some data is not directly comparable to past CBECs.

250

Evaluation of solar-air-heating central-receiver concepts  

DOE Green Energy (OSTI)

The potential of seven proposed air-heating central receiver concepts are evaluated based on an independent, uniform of each one's performance and cost. The concepts include: metal tubes, ceramic tubes, sodium heat pipes, ceramic matrix, ceramic domes, small particles, and volumetric heat exchange. The selection of design points considered in the analysis, the method and ground rules used in formulating the conceptual designs are discussed, and each concept design is briefly described. The method, ground rules, and models used in the performance evaluation and cost analysis and the results are presented. (LEW)

Bird, S.P.; Drost, M.K.; Williams, T.A.; Brown, D.R.; Fort, J.A.; Garrett-Price, B.A.; Hauser, S.G.; McLean, M.A.; Paluszek, A.M.; Young, J.K.

1982-06-01T23:59:59.000Z

251

TEE-0062 - In the Matter of United CoolAir Corp. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2 - In the Matter of United CoolAir Corp. 2 - In the Matter of United CoolAir Corp. TEE-0062 - In the Matter of United CoolAir Corp. This Decision and Order considers an Application for Exception filed by United CoolAir Corporation (United CoolAir) seeking exception relief from the provisions of 10 C.F.R. Part 431, Subpart F, Energy Conservation Program for Certain Commercial and Industrial Equipment: Commercial Air Conditioners and Heat Pumps Energy Conservation Standards (Commercial Air Conditioner Standards).1 In its Application, United CoolAir asserts that the firm would suffer serious hardship, inequity, or unfair distribution of burdens if required to comply with the 13 SEER energy efficiency standard effective January 1, 2010, 10 C.F.R. ツァ 431.97(b). If United CoolAir's Application for Exception were granted, the firm would

252

TEE-0062 - In the Matter of United CoolAir Corp. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

TEE-0062 - In the Matter of United CoolAir Corp. TEE-0062 - In the Matter of United CoolAir Corp. TEE-0062 - In the Matter of United CoolAir Corp. This Decision and Order considers an Application for Exception filed by United CoolAir Corporation (United CoolAir) seeking exception relief from the provisions of 10 C.F.R. Part 431, Subpart F, Energy Conservation Program for Certain Commercial and Industrial Equipment: Commercial Air Conditioners and Heat Pumps Energy Conservation Standards (Commercial Air Conditioner Standards).1 In its Application, United CoolAir asserts that the firm would suffer serious hardship, inequity, or unfair distribution of burdens if required to comply with the 13 SEER energy efficiency standard effective January 1, 2010, 10 C.F.R. ツァ 431.97(b). If United CoolAir's Application for Exception were granted, the firm would

253

Tips: Air Ducts | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Ducts Air Ducts Tips: Air Ducts June 24, 2013 - 7:23pm Addthis Air Ducts: Out of Sight, Out of Mind. The unsealed ducts in your attic and crawlspaces lose air, and uninsulated ducts lose heat -- wasting energy and money. Air Ducts: Out of Sight, Out of Mind. The unsealed ducts in your attic and crawlspaces lose air, and uninsulated ducts lose heat -- wasting energy and money. Your air ducts are one of the most important systems in your home, and if the ducts are poorly sealed or insulated they are likely contributing to higher energy bills. Your home's duct system is a branching network of tubes in the walls, floors, and ceilings; it carries the air from your home's furnace and central air conditioner to each room. Ducts are made of sheet metal, fiberglass, or other materials.

254

Definition: Heat pump | Open Energy Information  

Open Energy Info (EERE)

pump pump Jump to: navigation, search Dictionary.png Heat pump Heating and/or cooling equipment that, during the heating season, draws heat into a building from outside and, during the cooling season, ejects heat from the building to the outside[1] View on Wikipedia Wikipedia Definition A heat pump is a device that transfers heat energy from a heat source to a heat sink against a temperature gradient. Heat pumps are designed to move thermal energy opposite the direction of spontaneous heat flow. A heat pump uses some amount of external high-grade energy to accomplish the desired transfer of thermal energy from heat source to heat sink. While compressor-driven air conditioners and freezers are familiar examples of heat pumps, the term "heat pump" is more general and applies to

255

Hot tips on water heating  

SciTech Connect

Water-heater manufacturers responded to the call for energy conservation with innovations and efficiency standards for the home, business, and plant. Conventional tank-type water heaters offer better design and insulation, but the heat-pump water heater offers the highest efficiency. Available in add-on units and integral units, they now represent up to 40% of manufacturers' sales. Other advances are the desuperheater devices which recapture air-conditioner waste heat, solar-water-heating systems, instantaneous water heaters, and industrial heat-recovery systems for process water. 1 figure. (DCK)

Forker, J.

1982-03-01T23:59:59.000Z

256

Fetz Plumbing, Heating & Air Conditioning | Open Energy Information  

Open Energy Info (EERE)

Fetz Plumbing, Heating & Air Conditioning Fetz Plumbing, Heating & Air Conditioning Jump to: navigation, search Name Fetz Plumbing, Heating & Air Conditioning Address 115 Washington Street - P.O. Box 516 Place Urbana, Ohio Zip 43078 Sector Efficiency, Geothermal energy, Services, Solar Product Installation; Maintenance and repair Phone number 937-652-1136 Website http://fetzphc.com Coordinates 40.108862ツー, -83.757291ツー Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.108862,"lon":-83.757291,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

257

Artificial neural network control of a heat exchanger in a closed flow air circuit  

Science Conference Proceedings (OSTI)

This paper experimentally investigates the control of a heat exchanger in a closed flow air circuit. The temperature inside the test section of the test facility has been maintained at a set value by variation of air flow rate over the heat exchanger ... Keywords: Air circuit, Heat exchanger, Multi-layer perceptron, Neural network control, PID control

Kapil Varshney; P. K. Panigrahi

2005-07-01T23:59:59.000Z

258

Innovative Evaporative and Thermally Activated Technologies Improve Air Conditioning, The Spectrum of Clean Energy Innovation (Fact Sheet)  

NLE Websites -- All DOE Office Websites (Extended Search)

Innovative Evaporative and Innovative Evaporative and Thermally Activated Technologies Improve Air Conditioning Researchers at the National Renewable Energy Laboratory (NREL) invented a breakthrough technology that improves air conditioning in a novel way-with heat. NREL combined desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90% less electricity and up to 80% less total energy than traditional air conditioning (AC). This solution, called the desiccant enhanced evaporative air conditioner (DEVap), also controls humidity more effectively to improve the comfort of people in buildings. Desiccants are an example of a thermally activated technology (TAT) that relies on heat instead

259

EVALUATION OF A NEW SOLAR AIR CONDITIONER  

E-Print Network (OSTI)

with Dennis Hughes, FNBO, 2010. 9. U.S. EPA, eGrid 2007 Version 1.1, Year 2005 Summary Tables, Region MRO West (fossil fuel output). http://www. epa.gov/cleanenergy/energy-resources/ egrid/index.html (accessed

260

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and unnecessary expense. Set the fan speed on high, except on very humid days. When humidity is high, set the fan speed on low for more comfort. The low speed on humid days will...

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Kosciusko REMC - Residential Geothermal and Air-source Heat Pump Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Kosciusko REMC - Residential Geothermal and Air-source Heat Pump Kosciusko REMC - Residential Geothermal and Air-source Heat Pump Rebate Program Kosciusko REMC - Residential Geothermal and Air-source Heat Pump Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Appliances & Electronics Water Heating Maximum Rebate Maximum of two rebates per household Program Info State Indiana Program Type Utility Rebate Program Rebate Amount Geothermal System: $250 Air-Source Heat Pump: $150 Electric Water Heater: $75 - $125 Provider Kosciusko REMC Kosciusko REMC offers rebates (as bill credits) to residential members for the purchase and installation of high efficiency air-source heat pumps, geothermal heat pumps, and electric water heaters. For each purchase of an

262

Wabash County REMC - Residential Geothermal and Air-source Heat Pump Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Wabash County REMC - Residential Geothermal and Air-source Heat Wabash County REMC - Residential Geothermal and Air-source Heat Pump Rebate Program Wabash County REMC - Residential Geothermal and Air-source Heat Pump Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Appliances & Electronics Water Heating Maximum Rebate Geothermal: $750 Air Source Heat Pumps: $625 One rebate per house Program Info State Indiana Program Type Utility Rebate Program Rebate Amount Air Source Heat Pumps: $125 - $625/ton Geothermal Heat Pumps: $150 - $750/ton Water Heater: $100 Provider Wabash County REMC Wabash Rural Electric Membership Cooperative (REMC) is a member-owned electric distribution organization that provides service to customers in north-central Indiana. To encourage energy efficiency, Wabash County REMC

263

List of Compressed air Incentives | Open Energy Information  

Open Energy Info (EERE)

Energy Efficiency Incentive Program (Texas) Local Grant Program Texas Commercial Ceiling Fan Central Air conditioners Chillers Comprehensive MeasuresWhole Building Compressed air...

264

Comparative evaluation of the impacts of domestic gas and electric heat pump heating on air pollution in California  

SciTech Connect

Residential space and water heating accounts for approximately 12% of California's and 15% of the United States, energy consumption. most Of the residential heating is by direct use of natural gas. combustion of natural gas is a contributor to the overall air pollution,, especially CO and NO{sub x} in the urban areas. Another efficient method for domestic water and space heating is use of electric heat pumps, the most popular category of which uses air as its heat source. Electric heat pumps do not emit air pollutants at the point of use, but use electric power, which is a major contributor to air pollution at its point of generation from fossil fuels. It is the specific objective of this report to evaluate and compare the energy efficiency and source air pollutants of natural gas heaters and electric heat pumps used for domestic heating. Effect of replacing natural gas heaters with electric heat pumps on air pollutant emissions due to domestic heating in two urban areas and in California as a whole has also been evaluated. The analysis shows that with the present state of technology, electric heat pumps have higher heating efficiencies than natural gas heaters. Considering the current electricity generation mix in the US, electric heat pumps produce two to four times more NO{sub x}, much less CO, and comparable amount of CO{sub 2} per unit of useful heating energy compared to natural gas heaters. With California mix, electric heat pumps produce comparable NO{sub x} and much less CO and approximately 30% less CO{sub 2} per unit heat output. Replacement of natural gas heaters with electric heat pumps will slightly increase the overall NO{sub x}, and reduce CO and CO{sub 2} emissions in California. The effect of advanced technology power generation and heat pump heating has also been analyzed.

Ganji, A. (San Francisco State Univ., CA (United States). Div. of Engineering)

1992-07-01T23:59:59.000Z

265

Comparative evaluation of the impacts of domestic gas and electric heat pump heating on air pollution in California. Final report  

SciTech Connect

Residential space and water heating accounts for approximately 12% of California`s and 15% of the United States, energy consumption. most Of the residential heating is by direct use of natural gas. combustion of natural gas is a contributor to the overall air pollution,, especially CO and NO{sub x} in the urban areas. Another efficient method for domestic water and space heating is use of electric heat pumps, the most popular category of which uses air as its heat source. Electric heat pumps do not emit air pollutants at the point of use, but use electric power, which is a major contributor to air pollution at its point of generation from fossil fuels. It is the specific objective of this report to evaluate and compare the energy efficiency and source air pollutants of natural gas heaters and electric heat pumps used for domestic heating. Effect of replacing natural gas heaters with electric heat pumps on air pollutant emissions due to domestic heating in two urban areas and in California as a whole has also been evaluated. The analysis shows that with the present state of technology, electric heat pumps have higher heating efficiencies than natural gas heaters. Considering the current electricity generation mix in the US, electric heat pumps produce two to four times more NO{sub x}, much less CO, and comparable amount of CO{sub 2} per unit of useful heating energy compared to natural gas heaters. With California mix, electric heat pumps produce comparable NO{sub x} and much less CO and approximately 30% less CO{sub 2} per unit heat output. Replacement of natural gas heaters with electric heat pumps will slightly increase the overall NO{sub x}, and reduce CO and CO{sub 2} emissions in California. The effect of advanced technology power generation and heat pump heating has also been analyzed.

Ganji, A. [San Francisco State Univ., CA (United States). Div. of Engineering

1992-07-01T23:59:59.000Z

266

Air-Source Heat Pumps for Residential and Light Commercial Space Conditioning Applications  

Science Conference Proceedings (OSTI)

This technology brief provides the latest information on current and emerging air-source heat pump technologies for space heating and space cooling of residential and light commercial buildings. Air-source heat pumps provide important options that can reduce ownership costs while reducing noise and enhancing reliability and customer comfort. The tech brief also describes new air-source heat pumps with an important load shaping and demand response option.

2008-12-15T23:59:59.000Z

267

Geothermal Energy Development in the Eastern United States: Technical assistance report No. 6 geothermal space heating and airconditioning -- McGuire Air Force Base, New Jersey  

DOE Green Energy (OSTI)

A method of utilizing the geothermal (66 F) water resource for space heating and cooling of 200 of the 1452 housing units at McGuire AFB is suggested. Using projections of future costs of gas, coal and electricity made by DOD and by industry (Westinghouse), the relative costs of the geothermal-water-plus-heat-pump system and the otherwise-planned central gas heating (to be converted to coal in 1984) and air-conditioning (using individual electric units) system are compared. For heating with the geothermal/heat-pump system, an outlet temperature of 130 F is selected, requiring a longer running time than the conventional system (at 180 F) but permitting a COP (coefficient of performance) of the heat pump of about 3.4. For cooling (obtained in this study by changing directions of water flow, not refrigerant cycles), the change in temperature is less, and a COP near 4.5 is obtained. The cost of cooling in the summer months would be significantly less than the cost of using individual electric air-conditioners. Thus, by using nonreversible heat pumps, geothermal water is used to heat and to cool a section of the housing compound, minimizing operating expenditures. It is estimated that, to drill 1000 ft deep production and reinjection wells and to install ten heat pumps, heat exchangers and piping, would require a capital outlay of $643 K. This cost would replace the capital cost of purchasing and installing 200 air-conditioning units and 14% of the cost of the future coal-fired central heating system (which would otherwise serve all 1452 housing units at McGuire). The net additional capital outlay would be $299 K, which could be amortized in 10 years by the lower operating cost of the geothermal system if electricity and coal prices escalate as industry suggests. If the coal and electricity costs rise at the more modest rates that DOD projects, the capital costs would be amortized in a 15 year period.

Hill, F.K.; Briesen R. von

1980-12-01T23:59:59.000Z

268

High Efficiency Integrated Space Conditioning, Water Heating and Air Distribution System for HUD-Code Manufactured Housing  

SciTech Connect

Recognizing the need for new space conditioning and water heating systems for manufactured housing, DeLima Associates assembled a team to develop a space conditioning system that would enhance comfort conditions while also reducing energy usage at the systems level. The product, Comboflairツョ was defined as a result of a needs analysis of project sponsors and industry stakeholders. An integrated system would be developed that would combine a packaged airconditioning system with a small-duct, high-velocity air distribution system. In its basic configuration, the source for space heating would be a gas water heater. The complete system would be installed at the manufactured home factory and would require no site installation work at the homesite as is now required with conventional split-system air conditioners. Several prototypes were fabricated and tested before a field test unit was completed in October 2005. The Comboflairツョ system, complete with ductwork, was installed in a 1,984 square feet, double-wide manufactured home built by Palm Harbor Homes in Austin, TX. After the home was transported and installed at a Palm Harbor dealer lot in Austin, TX, a data acquisition system was installed for remote data collection. Over 60 parameters were continuously monitored and measurements were transmitted to a remote site every 15 minutes for performance analysis. The Comboflairツョ system was field tested from February 2006 until April 2007. The cooling system performed in accordance with the design specifications. The heating system initially could not provide the needed capacity at peak heating conditions until the water heater was replaced with a higher capacity standard water heater. All system comfort goals were then met. As a result of field testing, we have identified improvements to be made to specific components for incorporation into production models. The Comboflairツョ system will be manufactured by Unico, Inc. at their new production facility in St. Louis, MO. The product will be initially launched in the hot-humid climates of the southern U.S.

Henry DeLima; Joe Akin; Joseph Pietsch

2008-09-14T23:59:59.000Z

269

Weatherking Heating & Air conditioning | Open Energy Information  

Open Energy Info (EERE)

Page Page Edit with form History Facebook icon Twitter icon ツサ Weatherking Heating & Air conditioning Jump to: navigation, search Name Weatherking Heating & Air conditioning Address 51 Meadow Lane Place Northfield, Ohio Zip 44067 Sector Buildings, Efficiency, Geothermal energy, Renewable Energy, Services Product Business and legal services; Energy audits/weatherization; Energy provider: power production;Energy provider: wholesale;Engineering/architectural/design;Installation;Investment/finances;Maintenance and repair; Retail product sales and distribution Phone number 330-908-0281 Website http://www.weatherking1.com Coordinates 41.3340869ツー, -81.530299ツー Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.3340869,"lon":-81.530299,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

270

PERFORMANCE OF RESIDENTIAL AIR-TO-AIR HEAT EXCHANGERS: TEST METHODS AND RESULTS  

E-Print Network (OSTI)

Presenting Test Results Heat Exchanger Descriptions and Testof Residential Heat Exchangers Conclusions . . . . . . . .ventilation testing heat exchangers. system, a heat

Fisk, William J.

2013-01-01T23:59:59.000Z

271

Calendar Year 2007 Program Benefits for U.S. EPA Energy Star Labeled Products: Expanded Methodology  

E-Print Network (OSTI)

Gas or Oil) Central Air Conditioner Air-Source Heat PumpGas or Oil) - Central Air Conditioner - Air-Source HeatGas or Oil) - Central Air Conditioner - Air-Source Heat

Sanchez, Marla

2010-01-01T23:59:59.000Z

272

Mean and Variability of Air-Sea Heat Fluxes in the Indian Ocean  

E-Print Network (OSTI)

-sea heat Fluxes) Project: blended product planned activity: daily, 1ツコ-grid, mid 1950's ツュ present currently available: daily, 1ツコ-grid, 1988-2003 #12;OAFlux (Objectively Analyzed Air-sea Heat Fluxes) For the GlobalMean and Variability of Air-Sea Heat Fluxes in the Indian Ocean Lisan Yu Woods Hole Oceanographic

Yu, Lisan

273

Duke Energy - Heating & Cooling Equipment Loan Program (North...  

Open Energy Info (EERE)

Air conditioners, CaulkingWeather-stripping, DuctAir sealing, Building Insulation, Windows, Doors, Siding, Roofs Active Incentive No Implementing Sector Utility Energy Category...

274

Duke Energy - Heating & Cooling Equipment Loan Program (South...  

Open Energy Info (EERE)

Air conditioners, CaulkingWeather-stripping, DuctAir sealing, Building Insulation, Windows, Doors, Siding, Roofs Active Incentive No Implementing Sector Utility Energy Category...

275

Low-noise pulse conditioner  

DOE Patents (OSTI)

A low-noise pulse conditioner is provided for driving electronic digital processing circuitry directly from differentially induced input pulses. The circuit uses a unique differential-to-peak detector circuit to generate a dynamic reference signal proportional to the input peak voltage. The input pulses are compared with the reference signal in an input network which operates in full differential mode with only a passive input filter. This reduces the introduction of circuit-induced noise, or jitter, generated in ground referenced input elements normally used in pulse conditioning circuits, especially speed transducer processing circuits. This circuit may be used for conditioning the sensor signal from the Fidler coil in a gas centrifuge for separation of isotopic gaseous mixtures.

Bird, D.A.

1981-06-16T23:59:59.000Z

276

Energy Saving Technology of Thermal Regenerative Compressed Air Dryer by Regenerates Adsorbent with Residual Heat  

Science Conference Proceedings (OSTI)

According to the characteristic of the compressed air dryer located at the same place with the air compressor, for the large capacity thermal regenerative compressed air dryer that the absorbent is regenerated by an electric heater, this thesis puts ... Keywords: Compressed air dryer, Regeneration, Heater, Residual heat, Energy saving

Zhang Mingzhu; Zhou Zhili; Li Hongtao; Zhang Yongbo

2009-10-01T23:59:59.000Z

277

Radiative Heating Errors in Naturally Ventilated Air Temperature Measurements Made from Buoys*  

Science Conference Proceedings (OSTI)

Solar radiative heating errors in buoy-mounted, naturally ventilated air temperature sensors are examined. Data from sensors with multiplate radiation shields and collocated, fan-aspirated air temperature sensors from three buoy deployments ...

Steven P. Anderson; Mark F. Baumgartner

1998-02-01T23:59:59.000Z

278

Annual, Seasonal, and Interannual Variability of Air亡ea Heat Fluxes in the Indian Ocean  

Science Conference Proceedings (OSTI)

This study investigated the accuracy and physical representation of air穆ea surface heat flux estimates for the Indian Ocean on annual, seasonal, and interannual time scales. Six heat flux products were analyzed, including the newly developed ...

Lisan Yu; Xiangze Jin; Robert A. Weller

2007-07-01T23:59:59.000Z

279

W-12: Determination of Interfacial Heat Transfer and Air-gap ...  

Science Conference Proceedings (OSTI)

It is predicted for the Nickel-based alloy when the air-gap is below 0.3mm heat conduction is the dominant heat transfer process; above 0.3mm radiation is the...

280

An Air亡oil Layer Coupled Scheme for Computing Surface Heat Fluxes  

Science Conference Proceedings (OSTI)

An air穆oil layer coupled scheme is developed to compute surface fluxes of sensible heat and latent heat from data collected at the Oklahoma Atmospheric Radiation Measurement砲loud and Radiation Testbed (ARM砲ART) stations. This new scheme ...

Qin Xu; Binbin Zhou; Stephen D. Burk; Edward H. Barker

1999-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

List of Geothermal Heat Pumps Incentives | Open Energy Information  

Open Energy Info (EERE)

Heat Pumps Incentives Heat Pumps Incentives Jump to: navigation, search The following contains the list of 729 Geothermal Heat Pumps Incentives. CSV (rows 1-500) CSV (rows 501-729) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Appalachian Power - Commercial and Industrial Rebate Programs (West Virginia) Utility Rebate Program West Virginia Commercial Industrial Central Air conditioners Chillers Custom/Others pending approval Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Programmable Thermostats Commercial Refrigeration Equipment Ground Source Heat Pumps Yes AEP SWEPCO - Commercial and Industrial Energy Efficiency Rebate Programs (Arkansas) Utility Rebate Program Arkansas Commercial Fed. Government Industrial Institutional Local Government

282

Heat transfer pathways in underfloor air distribution (UFAD) systems  

E-Print Network (OSTI)

the following heat transfer processes: conduction throughtudes of the major heat transfer processes in a typical room

Bauman, F.; Jin, H.; Webster, T.

2006-01-01T23:59:59.000Z

283

State of the Art of Air-source Heat Pump for Cold Regions  

E-Print Network (OSTI)

In this paper, research on air source heat pump systems for cold regions in recent years is first summarized and compared. These systems can be divided into three kinds: a single-stage compression heat pump, liquid/vapor injection heat pump, and a two-stage heat pump. Finally, our research with a two-stage compression variable frequency air source heat pump is presented. A two-control-model with the priority target as COP or heating capacity is advanced. The experimental results show that the COP of this heat pump system is over 2, the compressor discharge temperature under 120, and the heating capacity can meet the heating load needed when the condensing temperature is 50 and outdoor air temperature is over -18.

Tian, C.; Liang, N.

2006-01-01T23:59:59.000Z

284

Research on Thermal Properties in a Phase Change Wallboard Room Based on Air Conditioning Cold Storage  

E-Print Network (OSTI)

After comparing the thermal performance parameters of an ordinary wall room to a phase change wall (PCW) room, we learn that phase change wallboard affects the fluctuation of temperature in air-conditioning room in the summer. We built a PCW room and an ordinary wall room, which are cooled by an air-conditioner. We used differential scanning calorimetry (DSC) to test the temperature field and heat flow fluctuation in these rooms. Through analyzing the data tested, we found that the mean temperature of PCW is lower than that of ordinary wall room by 1 to 2?, and PCW can lower the heat flow by 4.6W/m2. Combining phase change material with the building envelope can lower the indoor temperature, make the room thermally comfortable, and cut down the turn-on-and-off frequency of the air-conditioner and the primary investment and operating costs. It alleviates the urgent need for electricity.

Feng, G.; Li, W.; Chen, X.

2006-01-01T23:59:59.000Z

285

Experimental investigation on the photovoltaic-thermal solar heat pump air-conditioning system on water-heating mode  

Science Conference Proceedings (OSTI)

An experimental study on operation performance of photovoltaic-thermal solar heat pump air-conditioning system was conducted in this paper. The experimental system of photovoltaic-thermal solar heat pump air-conditioning system was set up. The performance parameters such as the evaporation pressure, the condensation pressure and the coefficient of performance (COP) of heat pump air-conditioning system, the water temperature and receiving heat capacity in water heater, the photovoltaic (PV) module temperature and the photovoltaic efficiency were investigated. The experimental results show that the mean photovoltaic efficiency of photovoltaic-thermal (PV/T) solar heat pump air-conditioning system reaches 10.4%, and can improve 23.8% in comparison with that of the conventional photovoltaic module, the mean COP of heat pump air-conditioning system may attain 2.88 and the water temperature in water heater can increase to 42 C. These results indicate that the photovoltaic-thermal solar heat pump air-conditioning system has better performances and can stably work. (author)

Fang, Guiyin; Hu, Hainan; Liu, Xu [Department of Physics, Nanjing University, Nanjing 210093 (China)

2010-09-15T23:59:59.000Z

286

Performance analysis of a two-stage variable capacity air source heat pump and a horizontal loop coupled ground source heat pump system.  

E-Print Network (OSTI)

??The thermal performance of a new two-stage variable capacity air source heat pump (ASHP) and a horizontal ground loop ground source heat pump (GSHP) was (more)

Safa, Amir Alizadeh

2012-01-01T23:59:59.000Z

287

Building Energy Software Tools Directory: Heat Pump Design Model  

NLE Websites -- All DOE Office Websites (Extended Search)

Heat Pump Design Model Heat Pump Design Model Heat Pump Design Model logo. Research tool for use in the steady-state simulation and design analysis of air-to-air heat pumps and air conditioners. The program can be used with most of the newer HFC refrigerants as well as with HCFCs and CFCs. The standard vapor-compression cycle is modeled with empirical representations for compressor performance and first-principle region-by-region modeling of the heat exchangers. An online Web version is available that can be used with default configurations or with user-specified component and operating parameters for analyzing the performance of single-speed, air-to-air equipment. User configurations can be saved for later use. Parametric analyses can be made and performance trends plotted online.

288

Fluidized bed heat exchanger with water cooled air distributor and dust hopper  

DOE Patents (OSTI)

A fluidized bed heat exchanger is provided in which air is passed through a bed of particulate material containing fuel. A steam-water natural circulation system is provided for heat exchange and the housing of the heat exchanger has a water-wall type construction. Vertical in-bed heat exchange tubes are provided and the air distributor is water-cooled. A water-cooled dust hopper is provided in the housing to collect particulates from the combustion gases and separate the combustion zone from a volume within said housing in which convection heat exchange tubes are provided to extract heat from the exiting combustion gases.

Jukkola, Walfred W. (Westport, CT); Leon, Albert M. (Mamaroneck, NY); Van Dyk, Jr., Garritt C. (Bethel, CT); McCoy, Daniel E. (Williamsport, PA); Fisher, Barry L. (Montgomery, PA); Saiers, Timothy L. (Williamsport, PA); Karstetter, Marlin E. (Loganton, PA)

1981-11-24T23:59:59.000Z

289

Optimization of the Fin Heat Pipe for Ventilating and Air Conditioning with a Genetic Algorithm  

E-Print Network (OSTI)

This paper illustrates that use of a heat pipe as a heat-reclaiming device can significantly influence the air-conditioning system. It analyzes the heat transfer model of the uniform annular fin heat pipe under the condition of air conditioning. It establishes functions of the fin structure parameters such as height,spacing and thickness of the fin when the volume of fin is the smallest under unit temperature difference and unit quantity of heat. It uses a genetic algorithm to optimize the model of the uniform annular fin heat pipe. The calculation result shows that the method of genetic algorithm is effective.

Qian, J.; Sun, D.; Li, G.

2006-01-01T23:59:59.000Z

290

Numerical Investigation of Air-Side Heat Transfer and Pressure Drop in Circular Finned-Tube Heat Exchangers.  

E-Print Network (OSTI)

??A three-dimensional numerical study is performed to investigate the heat transfer and pressure drop performance on the air-side of circular finned tube bundles in cross (more)

Mon, Mi Sandar

2003-01-01T23:59:59.000Z

291

GHPs Save Heating Cost and Improve Air Quality in Poultry Farm  

E-Print Network (OSTI)

: 40-50' wide, 400-500' length ツァ Bird density: 1 square foot/bird, 20,000 birds1 GHPs Save Heating Cost and Improve Air Quality in Poultry Farm per house ツァ Heating and cooling required ツァ Intensive ventilation to maintain air

292

Factors Regulating the Air亡ea Heat Fluxes Regime over the Aegean Sea  

Science Conference Proceedings (OSTI)

The authors examine the impact of low-frequency atmospheric forcings on the air穆ea heat fluxes over the Aegean Sea. The correlation between the air穆ea heat flux components and three established [North Atlantic Oscillation (NAO), east Atlantic...

Vassilis P. Papadopoulos; Aristides Bartzokas; Themistoklis Chronis; Dimitris Georgopoulos; George Ferentinos

2012-01-01T23:59:59.000Z

293

List of Heat pumps Incentives | Open Energy Information  

Open Energy Info (EERE)

pumps Incentives pumps Incentives Jump to: navigation, search The following contains the list of 1213 Heat pumps Incentives. CSV (rows 1-500) CSV (rows 501-1000) CSV (rows 1001-1213) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP (Central and North) - CitySmart Program (Texas) Utility Rebate Program Texas Commercial Industrial Institutional Local Government Schools Boilers Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Furnaces Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Roofs Windows Yes AEP (Central and SWEPCO) - Coolsaver A/C Tune Up (Texas) Utility Rebate Program Texas Commercial Installer/Contractor Residential Central Air conditioners

294

Heating and Cooling System Support Equipment Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heating and Cooling System Support Equipment Basics Heating and Cooling System Support Equipment Basics Heating and Cooling System Support Equipment Basics July 30, 2013 - 3:28pm Addthis Thermostats and ducts provide opportunities for saving energy. Dehumidifying heat pipes provide a way to help central air conditioners and heat pumps dehumidify air. Electric and gas meters allow users to track energy use. Thermostats Programmable thermostats can store and repeat multiple daily settings. Users can adjust the times heating or air-conditioning is activated according to a pre-set schedule. Visit the Energy Saver website for more information about thermostats and control systems in homes. Ducts Efficient and well-designed duct systems distribute air properly throughout a building, without leaking, to keep all rooms at a comfortable

295

Advanced Variable Speed Air-Source Integrated Heat Pumps Research Project |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Advanced Variable Speed Air-Source Advanced Variable Speed Air-Source Integrated Heat Pumps Research Project Advanced Variable Speed Air-Source Integrated Heat Pumps Research Project The U.S. Department of Energy is currently conducting research into advanced variable speed air-source integrated heat pumps (AS-IHPs). Project Description This project seeks to develop AS-IHP products for the larger air-source system market. Development focuses on a fully variable capacity or variable speed AS-IHP option. Project Partners Research is being undertaken through a cooperative research and development agreement (CRADA) between the Department of Energy, Oak Ridge National Laboratory, and a CRADA partner. Project Goals The goal of this project is the development of a fully variable-speed version of an AS-IHP product that can provide heating, ventilation, and air

296

Heat transfer pathways in underfloor air distribution (UFAD) systems  

E-Print Network (OSTI)

permission. QC-06-053 Heat Transfer Pathways in Underfloorchange the dynamics of heat transfer within a room as wellchange the dynamics of heat transfer within a room as well

Bauman, F.; Jin, H.; Webster, T.

2006-01-01T23:59:59.000Z

297

Buildings Energy Data Book: 5.3 Heating, Cooling, and Ventilation Equipment  

Buildings Energy Data Book (EERE)

3 3 Main Commercial Primary Energy Use of Heating and Cooling Equipment as of 1995 Heating Equipment | Cooling Equipment Packaged Heating Units 25% | Packaged Air Conditioning Units 54% Boilers 21% | Room Air Conditioning 5% Individual Space Heaters 2% | PTAC (2) 3% Furnaces 20% | Centrifugal Chillers 14% Heat Pumps 5% | Reciprocating Chillers 12% District Heat 7% | Rotary Screw Chillers 3% Unit Heater 18% | Absorption Chillers 2% PTHP & WLHP (1) 2% | Heat Pumps 7% 100% | 100% Note(s): Source(s): 1) PTHP = Packaged Terminal Heat Pump, WLHP = Water Loop Heat Pump. 2) PTAC = Packaged Terminal Air Conditioner BTS/A.D. Little, Energy Consumption Characteristics of Commercial Building HVAC Systems, Volume 1: Chillers, Refrigerant Compressors, and Heating Systems, Apr. 2001, Figure 5-5, p. 5-14 for cooling and Figure 5-10, p. 5-18 for heating

298

Economic Analysis of a Waste Water Resource Heat Pump Air-Conditioning System in North China  

E-Print Network (OSTI)

This paper describes the situation of waste water resource in north China and the characteristics and styles of a waste water resource heat pump system, and analyzes the economic feasibility of a waste water resource heat pump air-conditioning system including investment, operating fee and pay-back time. The results show that waste water resource heat pump air-conditioning system has a low investment, low operating fee and short payback time.

Chen, H.; Li, D.; Dai, X.

2006-01-01T23:59:59.000Z

299

Fresh Way to Cut Combustion, Crop and Air Heating Costs Avoids Million BTU Purchases: Inventions and Innovation Combustion Success Story  

DOE Green Energy (OSTI)

Success story written for the Inventions and Innovation Program about a new space heating method that uses solar energy to heat incoming combustion, crop, and ventilation air.

Wogsland, J.

2001-01-17T23:59:59.000Z

300

Atmospheric Forcing of the Winter Air亡ea Heat Fluxes over the Northern Red Sea  

Science Conference Proceedings (OSTI)

The influence of the atmospheric circulation on the winter air穆ea heat fluxes over the northern Red Sea is investigated during the period 19852011. The analysis based on daily heat flux values reveals that most of the net surface heat exchange ...

Vassilis P. Papadopoulos; Yasser Abualnaja; Simon A. Josey; Amy Bower; Dionysios E. Raitsos; Harilaos Kontoyiannis; Ibrahim Hoteit

2013-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

E-Print Network (OSTI)

was used to forecast electricity prices into the future (Case forecasts residential electricity prices to decline to

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-01-01T23:59:59.000Z

302

Duke Energy - Residential and Builder Energy Efficiency Rebate...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pump: 300 (builder) New Home Air Conditioner: 300 (builder) Attic Insulation and Air Sealing: 250 Duct Sealing: 100 Heat Pump and Air Conditioner Tune Up: 50 AC...

303

Vehicle cabin cooling system for capturing and exhausting heated boundary layer air from inner surfaces of solar heated windows  

DOE Patents (OSTI)

The cabin cooling system includes a cooling duct positioned proximate and above upper edges of one or more windows of a vehicle to exhaust hot air as the air is heated by inner surfaces of the windows and forms thin boundary layers of heated air adjacent the heated windows. The cabin cooling system includes at least one fan to draw the hot air into the cooling duct at a flow rate that captures the hot air in the boundary layer without capturing a significant portion of the cooler cabin interior air and to discharge the hot air at a point outside the vehicle cabin, such as the vehicle trunk. In a preferred embodiment, the cooling duct has a cross-sectional area that gradually increases from a distal point to a proximal point to the fan inlet to develop a substantially uniform pressure drop along the length of the cooling duct. Correspondingly, this cross-sectional configuration develops a uniform suction pressure and uniform flow rate at the upper edge of the window to capture the hot air in the boundary layer adjacent each window.

Farrington, Robert B. (Golden, CO); Anderson, Ren (Broomfield, CO)

2001-01-01T23:59:59.000Z

304

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Desiccant Enhanced Evaporative Air Conditioning Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning May 29, 2012 - 5:22pm Addthis This breakthrough combines desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90 percent less electricity and up to 80 percent less total energy than traditional air conditioning. This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings. View the entire Lab Breakthrough playlist. What are the key facts? Recent materials advances and liquid desiccant advances to design the compact and cost-effective DEVAP system. DEVAP uses 90 percent less electricity and up to 80 percent less

305

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning May 29, 2012 - 5:22pm Addthis This breakthrough combines desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90 percent less electricity and up to 80 percent less total energy than traditional air conditioning. This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings. View the entire Lab Breakthrough playlist. What are the key facts? Recent materials advances and liquid desiccant advances to design the compact and cost-effective DEVAP system.

306

Air flow in a high aspect ratio heat sink  

E-Print Network (OSTI)

The increasing heat output of modern electronics requires concomitant advances in heat sinking technology: reductions in thermal resistance and required pumping power are necessary. This research covers the development of ...

Allison, Jonathan Michael

2010-01-01T23:59:59.000Z

307

Heat transfer pathways in underfloor air distribution (UFAD) systems  

E-Print Network (OSTI)

displacement venti- lation. ASHRAE Transactions 105(1):298309. ASHRAE Transactionsunderfloor air supply plenums. ASHRAE Trans- actions 112(2).

Bauman, F.; Jin, H.; Webster, T.

2006-01-01T23:59:59.000Z

308

Air emissions from residential heating: The wood heating option put into environmental perspective. Report for June 1997--July 1998  

SciTech Connect

The paper compares the national scale (rather than local) air quality impacts of the various residential space heating options. Specifically, it compares the relative contributions of the space heating options to fine particulate emissions, greenhouse gas emissions, and acid precipitation impacts. The major space heating energy options are natural gas, fuel oil, kerosene, liquefied petroleum gas (LPG), electricity, coal, and wood. Residential wood combustion (RWC) meets 9% of the Nation`s space heating energy needs and utilizes a renewable resource. Wood is burned regularly in about 30 million homes. Residential wood combustion is often perceived as environmentally dirty due to emissions from older wood burners.

Houck, J.E.; Tiegs, P.E.; McCrillis, R.C.; Keithley, C.; Crouch, J.

1998-12-31T23:59:59.000Z

309

Covered Product Category: Residential Air-Source Heat Pumps | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Air-Source Heat Pumps Residential Air-Source Heat Pumps Covered Product Category: Residential Air-Source Heat Pumps October 7, 2013 - 10:35am Addthis ENERGY STAR logo FEMP provides acquisition guidance across a variety of product categories, including residential air-source heat pumps (ASHPs), which are an ENERGY STARツョ-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases

310

Covered Product Category: Residential Air-Source Heat Pumps | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air-Source Heat Pumps Air-Source Heat Pumps Covered Product Category: Residential Air-Source Heat Pumps October 7, 2013 - 10:35am Addthis ENERGY STAR logo FEMP provides acquisition guidance across a variety of product categories, including residential air-source heat pumps (ASHPs), which are an ENERGY STARツョ-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

311

An Analytical Model of Heating Errors in Marine Air Temperatures from Ships  

Science Conference Proceedings (OSTI)

Marine air temperature reports from ships can contain significant biases due to the solar heating of the instruments and their surroundings. However, there have been very few attempts to derive corrections. The biases can reverse the sign of the ...

David I. Berry; Elizabeth C. Kent; Peter K. Taylor

2004-08-01T23:59:59.000Z

312

HEAT PUMP AND AIR CONDITIONING SYSTEM ANALYSIS BASED ON VARIABLE SPEED COMPRESSOR.  

E-Print Network (OSTI)

??Mechanical Engineering M.S.E. Experiments were carried out to investigate the effect of ambient air temperatures on the heat pump performance using a variable speed compressor. (more)

Zhang, Hao

2010-01-01T23:59:59.000Z

313

The Effects of Small-Scale Turbulence on Air亡ea Heat Flux  

Science Conference Proceedings (OSTI)

The air穆ea exchange of heat is mainly controlled by the molecular diffusive layer adjacent to the surface. With an order of magnitude difference between the kinematic viscosity and thermal diffusivity of water, the thermal sublayer is embedded ...

Fabrice Veron; W. Kendall Melville; Luc Lenain

2011-01-01T23:59:59.000Z

314

Intercomparisons of Air亡ea Heat Fluxes over the Southern Ocean  

Science Conference Proceedings (OSTI)

Consistency and discrepancy of air穆ea latent and sensible heat fluxes (LHF and SHF, respectively) in the Southern Ocean for current-day flux products are analyzed from climatology and interannual-to-decadal variability perspectives. Five flux ...

Jiping Liu; Tingyin Xiao; Liqi Chen

2011-02-01T23:59:59.000Z

315

Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI  

Energy.gov (U.S. Department of Energy (DOE))

These comments are submitted by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) in response to the U.S. Department of Energy痴 (DOE) notice in the August 8, 2012 Federal Register...

316

Inverse Analysis Adjustment of the SOC Air亡ea Flux Climatology Using Ocean Heat Transport Constraints  

Science Conference Proceedings (OSTI)

Results are presented from a linear inverse analysis of the Southampton Oceanography Centre (SOC) air穆ea flux climatology using 10 hydrographic ocean heat transport constraints distributed throughout the Atlantic and North Pacific Oceans. A ...

Jeremy P. Grist; Simon A. Josey

2003-10-01T23:59:59.000Z

317

Parameterizations of Sea-Spray Impact on the Air亡ea Momentum and Heat Fluxes  

Science Conference Proceedings (OSTI)

This paper focuses on parameterizing the effect of sea spray at hurricane-strength winds on the momentum and heat fluxes in weather prediction models using the Monin飽bukhov similarity theory (a common framework for the parameterizations of air...

J.-W. Bao; C. W. Fairall; S. A. Michelson; L. Bianco

2011-12-01T23:59:59.000Z

318

Measuring important parameters for air-sea heat exchange Christoph S. Garbeab, Uwe Schimpfab and Bernd Jhneab  

E-Print Network (OSTI)

Measuring important parameters for air-sea heat exchange Christoph S. Garbeab, Uwe Schimpfab Exchange, Heat flux, Digital Image Processing, Surface Renewal 1. INTRODUCTION Thermographic techniques-water heat exchange. A driving force in air sea interactions is the net sea surface heat flux. It is a vital

Garbe, Christoph S.

319

Energy Performance Comparison of Heating and Air Conditioning Systems for Multi-Family Residential Buildings  

SciTech Connect

The type of heating, ventilation and air conditioning (HVAC) system has a large impact on the heating and cooling energy consumption in multifamily residential buildings. This paper compares the energy performance of three HVAC systems: a direct expansion (DX) split system, a split air source heat pump (ASHP) system, and a closed-loop water source heat pump (WSHP) system with a boiler and an evaporative fluid cooler as the central heating and cooling source. All three systems use gas furnace for heating or heating backup. The comparison is made in a number of scenarios including different climate conditions, system operation schemes and applicable building codes. It is found that with the minimum code-compliant equipment efficiency, ASHP performs the best among all scenarios except in extremely code climates. WSHP tends to perform better than the split DX system in cold climates but worse in hot climates.

Wang, Weimin; Zhang, Jian; Jiang, Wei; Liu, Bing

2011-07-31T23:59:59.000Z

320

HVAC Technology Report: A Review of Heating, Ventilation and Air Conditioning Technology and Markets  

Science Conference Proceedings (OSTI)

For many of us, roughly 95 percent of our time is spent indoors. To enable humans to spend this much time inside, mechanical equipment is necessary to provide space conditioning to control the temperature (heating and cooling), ventilation, humidity, and indoor air quality. This report introduces the heating, ventilation, and air-conditioning (HVAC) industry to EPRI member utility employees. The document describes the most common technologies and applications and provides an overview of industry statisti...

2000-12-14T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Influence of air conditioning management on heat island in Paris air street temperatures  

E-Print Network (OSTI)

spatial cartography of air- cooled chillers and cooling towers in the city of Paris and surroundings have); secondly the actual situation including individual air dry coolers, wet cooling towers and an urban cooling the air cooling demand. Results of a meso-scale meteorological model (MESO-NH), coupled to an urban energy

322

Analysis of historical residential air-conditioning equipment sizing using monitored data  

SciTech Connect

Monitored data were analyzed to determine whether residential air conditioners in the Pacific Northwest historically have been sized properly to meet or slightly exceed actual cooling requirements. Oversizing air-conditioning equipment results in a loss of efficiency because of increased cycling and also lowers humidity control. On the other hand, the penalty of undersizing air-conditioning equipment may be some loss of comfort during extremely hot weather. The monitored data consist of hourly space-conditioning electrical energy use and internal air temperature data collected during the past 7 years from 75 residences in the Pacific Northwest. These residences are equipped with central air conditioners or heat pumps. The periods with the highest cooling energy use were analyzed for each site. A standard industry sizing methodology was used for each site to determine a sizing estimate. Both the sizing recommendation based on Manual J and peak monitored loads are compared to the capacity of the installed equipment for each site to study how the actual capacity differed from both the estimate of proper sizing and from actual demands. Characteristics of the maximum cooling loads are analyzed here to determine which conditions put the highest demand on the air conditioner. Specifically, internal air temperature data are used to determine when the highest cooling loads occur, at constant thermostat settings or when the thermostat was set down. This analysis of monitored data also provides insight into the extent that occupant comfort may be affected by undersizing air conditioners. The findings of this research indicate that cooling equipment historically has often but not always been oversized beyond industry-recommended levels. However, some occupants in homes with undersized, properly sized, and, in rare occasions, even oversized cooling equipment appear to suffer because the cooling equipment cannot always provide adequate cooling. Key findings are summarized.

Lucas, R.G.

1993-02-01T23:59:59.000Z

323

Determining the quality and quantity of heat produced by proton exchange membrane fuel cells with application to air-cooled stacks for combined heat and power  

E-Print Network (OSTI)

Determining the quality and quantity of heat produced by proton exchange membrane fuel cells Determining the quality and quantity of heat produced by proton exchange membrane fuel cells with application, the coolant is pumped to a heat recovery system. A water-to-air heat exchange system or water-to-water heat

Victoria, University of

324

Register Closing Effects on Forced Air Heating System Performance  

E-Print Network (OSTI)

Air Handler Power - Climate Zone 16 48 hr avg 24 hr avg FarAverage Gas Power - Climate Zone 16 48 hr avg 24 hr avg NearAverage Gas Power - Climate Zone 16 48 hr avg Near Registers

Walker, Iain S.

2003-01-01T23:59:59.000Z

325

Homeowner's Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet), Building America Case Study: Technology Solutions for Existing Homes, Building Technologies Office (BTO)  

SciTech Connect

This fact sheet offers a step-by-step guide to proper installation of window air conditioning units, in order to improve efficiency and comfort for homeowners.

2013-06-01T23:59:59.000Z

326

List of Heat recovery Incentives | Open Energy Information  

Open Energy Info (EERE)

recovery Incentives recovery Incentives Jump to: navigation, search The following contains the list of 174 Heat recovery Incentives. CSV (rows 1 - 174) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial Custom Project Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Fed. Government Industrial Institutional Local Government Nonprofit Schools State Government Tribal Government Boilers Central Air conditioners Chillers Custom/Others pending approval Furnaces Heat pumps Heat recovery Lighting Lighting Controls/Sensors Processing and Manufacturing Equipment Refrigerators Yes AEP Ohio - Commercial Self Direct Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Fed. Government Industrial Institutional Local Government

327

Estimating Monthly Averaged Air-Sea Transfers of Heat and Momentum Using the Bulk Aerodynamic Method  

Science Conference Proceedings (OSTI)

Air-sea transfers of sensible heat, latent heat and momentum are computed from 25 years of middle-latitude and subtropical ocean weather ship data in the North Atlantic and North Pacific using the bulk aerodynamic method. The results show that ...

Steven K. Esbensen; Richard W. Reynolds

1981-04-01T23:59:59.000Z

328

FEMP--Geothermal Heat Pumps  

NLE Websites -- All DOE Office Websites (Extended Search)

conditioner or refrigera- tor-moves heat from one place to another. In the summer, a geothermal heat pump (GHP) operating in a cooling mode lowers indoor temperatures by...

329

Opportunities for Saving Energy and Improving Air Quality in Urban Heat Islands  

SciTech Connect

World energy use is the main contributor to atmospheric CO2. In 2002, about 7.0 giga metric tons of carbon (GtC) were emitted internationally by combustion of gas, liquid, and solid fuels (CDIAC, 2006), 2 to 5 times the amount contributed by deforestation (Brown et al., 1988). The share of atmospheric carbon emissions for the United States from fossil fuel combustion was 1.6 GtC. Increasing use of fossil fuel and deforestation together have raised atmospheric CO{sub 2} concentration some 25% over the last 150 years. According to global climate models and preliminary measurements, these changes in the composition of the atmosphere have already begun raising the Earth's average temperature. If current energy trends continue, these changes could drastically alter the Earth's temperature, with unknown but potentially catastrophic physical and political consequences. During the last three decades, increased energy awareness has led to conservation efforts and leveling of energy consumption in the industrialized countries. An important byproduct of this reduced energy use is the lowering of CO{sub 2} emissions. Of all electricity generated in the United States, about one-sixth is used to air-condition buildings. The air-conditioning use is about 400 tera-watt-hours (TWh), equivalent to about 80 million metric tons of carbon (MtC) emissions, and translating to about $40 billion (B) per year. Of this $40 B/year, about half is used in cities that have pronounced 'heat islands'. The contribution of the urban heat island to the air-conditioning demand has increased over the last 40 years and it is currently at about 10%. Metropolitan areas in the United States (e.g., Los Angeles, Phoenix, Houston, Atlanta, and New York City) have typically pronounced heat islands that warrant special attention by anyone concerned with broad-scale energy efficiency (HIG, 2006). The ambient air is primarily heated through three processes: direct absorption of solar radiation, convection of heat from hot surfaces, and man-made heat (exhaust from cars, buildings, etc.). Air is fairly transparent to light--the direct absorption of solar radiation in atmospheric air only raises the air temperature by a small amount. Typically about 90% of solar radiation reaches the Earth's surface and then is either absorbed or reflected. The absorbed radiation on the surface increases the surface temperature. And in turn the hot surfaces heat the air. This convective heating is responsible for the majority of the diurnal temperature range. The contribution of man-made heat (e.g., air conditioning, cars) is very small, compared to the heating of air by hot surfaces, except for the downtown high-rise areas.

Akbari, Hashem

2007-07-01T23:59:59.000Z

330

Characterization of crushed glass as a transpired air heating solar collector material  

DOE Green Energy (OSTI)

The use of crushed glass matrices as the heat-absorbing media in air heating solar collectors is investigated. An experimantal program was undertaken to characterize the most likely candidate glass types and sizes by measuring pressure drops, optical extinction coefficients, and volumetric heat transfer coefficients. Bed efficiencies were also measured and found to be similar to those expected for screen matrices unless critical amounts of clear glass were used as a top layer, which results in lower efficiency.

Collier, R.K.

1979-01-01T23:59:59.000Z

331

Heat transfer and pressure drop measurements in an air/molten salt direct-contact heat exchanger  

SciTech Connect

This paper presents a comparison of experimental data with a recently published model of heat exchange in irrigated packed beds. Heat transfer and pressure drop were measured in a 150 mm (ID) column with a 610-mm bed of metal Pall rings. Molten nitrate salt and preheated air were the working fluids with a salt inlet temperature of approximately 440{degree}C and air inlet temperatures of approximately 230{degree}C. A comparison between the experimental data and the heat transfer model is made on the basis of heat transfer from the salt. For the range of air and salt flow rates tested, 0.3 to 1.2 kg/m{sup 2} s air flow and 6 to 18 kg/m{sup 2} s salt flow, the data agree with the model within 22% standard deviation. In addition, a model for the column pressure drop was validated, agreeing with the experimental data within 18% standard deviation over the range of column pressure drop from 40 to 1250 Pa/m. 25 refs., 7 figs., 2 tabs.

Bohn, M.S.

1988-11-01T23:59:59.000Z

332

Documentation of Calculation Methodology, Input data, and Infrastructure for the Home Energy Saver Web Site  

E-Print Network (OSTI)

heat pump (heating) Electric baseboard heater Gas boilerOil boiler Central air conditioner Room air conditioner18 3.1.6.1 Boiler Pipe

2005-01-01T23:59:59.000Z

333

Unified power quality conditioner for grid integration of wind generators.  

E-Print Network (OSTI)

?? A Unified Power Quality Conditioner (UPQC) is relatively a new member of the custom power device family. It is a comprehensive custom power device, (more)

Ganesh, Jayanti Navilgone, (Thesis)

2008-01-01T23:59:59.000Z

334

Direct-contact air/molten salt heat exchange for solar-thermal systems  

DOE Green Energy (OSTI)

Heat exchangers employing direct contact between molten draw salt and air were studied for use in solar industrial process heat (IPH) systems. Direct-contact systems consisting of a fin-tube preheater and a spray or packed column were compared to conventional heat exchangers. Direct contact reduced the IPH system cost by 5% to 10%. The direct-contact heat exchangers cost only 15% to 30% as much as comparable conventional exchangers. However, the rate of salt degradation by CO/sup 2/ and H/sub 2/O must be determined to see if it is acceptable.

Wright, J.D.; d'Agincourt, C.

1982-05-01T23:59:59.000Z

335

Air-Con International: Noncompliance Determination and Proposed Penalty  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Con International: Noncompliance Determination and Proposed Con International: Noncompliance Determination and Proposed Penalty (2010-SE-0301) Air-Con International: Noncompliance Determination and Proposed Penalty (2010-SE-0301) September 20, 2010 DOE issued a Notice of Noncompliance Determination to Air-Con International finding that a variety of central air conditioners and air conditioning heat pumps distributed under the Air-Con private label do not comport with the energy conservation standards. DOE also alleged in a Notice of Proposed Civil Penalty that Air-Con imported and distributed the noncompliant products in the U.S. Federal law subjects manufacturers and private labelers to civil penalties if those parties distribute in the U.S. products that do not meet applicable energy conservation standards. This

336

Experimental study on corrugated cross-flow air-cooled plate heat exchangers  

SciTech Connect

Experimental study on cross-flow air-cooled plate heat exchangers (PHEs) was performed. The two prototype PHEs were manufactured in a stack of single-wave plates and double-wave plates in parallel. Cooling air flows through the PHEs in a crosswise direction against internal cooling water. The heat exchanger aims to substitute open-loop cooling towers with closed-loop water circulation, which guarantees cleanliness and compactness. In this study, the prototype PHEs were tested in a laboratory scale experiments. From the tests, double-wave PHE shows approximately 50% enhanced heat transfer performance compared to single-wave PHE. However, double-wave PHE costs 30% additional pressure drop. For commercialization, a wide channel design for air flow would be essential for reliable performance. (author)

Kim, Minsung; Baik, Young-Jin; Park, Seong-Ryong; Ra, Ho-Sang [Solar Thermal and Geothermal Research Center, Korea Institute of Energy Research, Daejeon 305-343 (Korea); Lim, Hyug [Research and Development Center, LHE Co., Ltd., Gimhae 621-874 (Korea)

2010-11-15T23:59:59.000Z

337

Method and apparatus for operating a self-starting air heating system  

DOE Patents (OSTI)

A self-starting, fuel fired, air heating system including a fuel burner fired vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser and heating the air. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with a method and apparatus which on start-up prevents the vapor generator's vapor output from being conducted to the turbine until a predetermined pressure differential has been achieved. However, after the vapor flow is once permitted, it cannot again be prevented until after the fuel burner has been shut off and restarted.

Heinrich, Charles E. (Mentor, OH)

1983-12-06T23:59:59.000Z

338

Existing and Past Methods of Test and Rating Standards Related to Integrated Heat Pump Technologies  

Science Conference Proceedings (OSTI)

This report evaluates existing and past US methods of test and rating standards related to electrically operated air, water, and ground source air conditioners and heat pumps, 65,000 Btu/hr and under in capacity, that potentiality incorporate a potable water heating function. Two AHRI (formerly ARI) standards and three DOE waivers were identified as directly related. Six other AHRI standards related to the test and rating of base units were identified as of interest, as they would form the basis of any new comprehensive test procedure. Numerous other AHRI and ASHRAE component test standards were also identified as perhaps being of help in developing a comprehensive test procedure.

Reedy, Wayne R. [Sentech, Inc.

2010-07-01T23:59:59.000Z

339

CHAMPS-Multizone-A Combined Heat, Air, Moisture and Pollutant Simulation  

NLE Websites -- All DOE Office Websites (Extended Search)

CHAMPS-Multizone-A Combined Heat, Air, Moisture and Pollutant Simulation CHAMPS-Multizone-A Combined Heat, Air, Moisture and Pollutant Simulation Environment for Whole-building Performance Analysis Title CHAMPS-Multizone-A Combined Heat, Air, Moisture and Pollutant Simulation Environment for Whole-building Performance Analysis Publication Type Journal Article Year of Publication 2012 Authors Zhang, J. S., Wei Feng, John Grunewald, Andreas Nicolai, and Carey Zhang Journal HVAC&R Research Volume 18 Issue 1-2 Abstract A computer simulation tool, named "CHAMPS-Multizone" is introduced in this paper for analyzing bothenergy and IAQ performance of buildings. The simulation model accounts for the dynamic effects ofoutdoor climate conditions (solar radiation, wind speed and direction, and contaminant concentrations),building materials and envelope system design, multizone air and contaminant flows in buildings,internal heat and pollutant sources, and operation of the building HVAC systems on the buildingperformance. It enables combined analysis of building energy efficiency and indoor air quality. Themodel also has the ability to input building geometry data and HVAC system operation relatedinformation from software such as SketchUp and DesignBuilder via IDF file format. A "bridge" to accessstatic and dynamic building data stored in a "virtual building" database is also developed, allowingconvenient input of initial and boundary conditions for the simulation, and for comparisons between thepredicted and measured results. This paper summarizes the mathematical models, adoptedassumptions, methods of implementation, and verification and validation results. The needs andchallenges for further development are also discussed

340

Improving air handler efficiency in houses  

SciTech Connect

Although furnaces, air conditioners and heat pumps have become significantly more efficient over the last couple of decades, residential air handlers have typical efficiencies of only 10% to 15% due to poor electric motor performance and aerodynamically poor fans and fan housings. Substantial increases in performance could be obtained through improved air handler design and construction. A prototype residential air handler intended to address these issues has recently been developed. The prototype and a standard production fan were tested in a full-scale duct system and test chamber at LBNL specifically designed for testing heating, ventilation, and air conditioning systems. The laboratory tests compared efficiency, total airflow, sensitivity to duct system flow resistance, and the effects of installation in a smaller cabinet. The test results showed that the prototype air handler had about twice the efficiency of the standard air handler (averaged over a wide range of operating conditions) and was less sensitive to duct system flow resistance changes. The performance of both air handlers was significantly reduced by reducing the clearance between the air handler and cabinet it was placed in. These test results showed that in addition to the large scope for performance improvement, air handler fans need to be tested in the cabinets they operate in.

Walker, Iain S.

2004-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

High Levels of Winter Air Pollution under the Influence of the Urban Heat Island along the Shore of Tokyo Bay  

Science Conference Proceedings (OSTI)

A wintertime small-scale sea breeze associated with high levels of air pollution is described, in which the urban heat island plays an important role.

Hiroshi Yoshikado; Makoto Tsuchida

1996-10-01T23:59:59.000Z

342

Experimental Study of Heat Transfer and Flow Characteristics for a New Type of Air Heater  

E-Print Network (OSTI)

A new type air heater was developed, and an experimental set-up was built to analyze its characteristics. Within the Reynolds number from 2000 to 15000, the integrated characteristics in air heater channels with and without holed baffles have been studied experimentally. The experimental results show that the average Nu number increases greatly but the friction factor increases only slightly with the Re number. The Webb performance evaluation criterion has been adopted for analysis purposes. It is found that the integrated characteristics of heat transfer and flow friction increase with the hole's diameter at the same hole density (which is equal to the ratio of the hole's total area to the baffle's area), and the heat transfer rate increases with the hole density at the same hole diameter. The C type baffle has the best performance at the same heat transfer surface area and fan power consumption; its heat transfer rate improves about 44 to 69 percent.

Zheng, H.; Fan, X.; Li, A.

2006-01-01T23:59:59.000Z

343

Heat transfer and pressure drop for air flow through enhanced passages. Final report  

SciTech Connect

An extensive experimental investigation was carried out to determine the pressure drop and heat transfer characteristics for laminar, transitional and turbulent flow of air through a smooth passage and twenty-three enhanced passages. The internal surfaces of all enhanced passages had spirally shaped geometries; these included fluted, finned/ribbed and indented surfaces. The Reynolds number (Re) was varied between 400 and 50000. The effect of heat transfer (wall cooling or fluid heating) on pressure drop is most significant within the transition region; the recorded pressure drop with heat transfer is much higher than that without heat transfer. The magnitude of this effect depends markedly on the average surface temperature and, to a lesser extent, on the geometric characteristics of the enhanced surfaces. When the pressure drop data are reduced as values of the Fanning friction factor(f), the results are about the same with and without heat transfer for turbulent flow, with moderate differences in the laminar and transition regions.

Obot, N.T.; Esen, E.B.

1992-06-01T23:59:59.000Z

344

Heat transfer and pressure drop for air flow through enhanced passages  

SciTech Connect

An extensive experimental investigation was carried out to determine the pressure drop and heat transfer characteristics for laminar, transitional and turbulent flow of air through a smooth passage and twenty-three enhanced passages. The internal surfaces of all enhanced passages had spirally shaped geometries; these included fluted, finned/ribbed and indented surfaces. The Reynolds number (Re) was varied between 400 and 50000. The effect of heat transfer (wall cooling or fluid heating) on pressure drop is most significant within the transition region; the recorded pressure drop with heat transfer is much higher than that without heat transfer. The magnitude of this effect depends markedly on the average surface temperature and, to a lesser extent, on the geometric characteristics of the enhanced surfaces. When the pressure drop data are reduced as values of the Fanning friction factor(f), the results are about the same with and without heat transfer for turbulent flow, with moderate differences in the laminar and transition regions.

Obot, N.T.; Esen, E.B.

1992-06-01T23:59:59.000Z

345

Bulk Formulation of the Heat and Water Vapor Fluxes at the Air亡ea Interface, Including Nonmolecular Contributions  

Science Conference Proceedings (OSTI)

Accurate prediction of the air穆ea sensible and latent heat fluxes is vital for nearly all applications of atmosphere and ocean models. Existing theories of heat transfer over rough surfaces provide a starting point, but they seem incomplete ...

James A. Mueller; Fabrice Veron

2010-01-01T23:59:59.000Z

346

Air亡ea Heat Flux Measurements from Nearly Neutrally Buoyant Floats  

Science Conference Proceedings (OSTI)

The ability of neutrally buoyant, high-drag floats to measure the air穆ea heat flux from within the turbulent oceanic boundary layer is investigated using float data from four different winter and fall float deployments. Two flux estimates can be ...

Eric A. D'Asaro

2004-07-01T23:59:59.000Z

347

Transpired Solar Collector at NREL's Waste Handling Facility Uses Solar Energy to Heat Ventilation Air  

Energy.gov (U.S. Department of Energy (DOE))

Revised fact sheet describes the transpired solar collector that was installed on NREL's Waste handling Facility (WHF) in 1990 to preheat ventilation air. The electrically heated WHF was an ideal candidate for this technology - requiring a ventilation rate of 3,000 cubic feet per meter to maintain safe indoor conditions.

348

Equatorial Waves in the Presence of Air-Sea Heat Exchange  

Science Conference Proceedings (OSTI)

Changes in propagation of free linear waves on the equatorial ?-plane associated with air-sea heat exchange are in investigated here. By using a mixed-layer model, with the waves considered as perturbations on a specified basic state, the usual ...

Howard P. Hanson

1983-07-01T23:59:59.000Z

349

Measurements of Momentum and Heat Transfer across the Air亡ea Interface  

Science Conference Proceedings (OSTI)

This study makes direct measurements of turbulent fluxes in the mixed layer in order to close heat and momentum budgets across the air穆ea interface and to assess the ability of rigid-boundary turbulence models to predict mean vertical gradients ...

Gregory P. Gerbi; John H. Trowbridge; James B. Edson; Albert J. Plueddemann; Eugene A. Terray; Janet J. Fredericks

2008-05-01T23:59:59.000Z

350

Experimental study of the heat and mass transfer in a packed bed liquid desiccant air dehumidifier  

Science Conference Proceedings (OSTI)

Desiccant cooling systems have the ability to provide efficient humidity and temperature control while reducing the electrical energy requirement for air conditioning as compared to a conventional system. Naturally, the desiccant air dehumidification process greatly influences the overall performance of the desiccant system. Therefore, the effects of variables such as air and desiccant flow rates, air temperature and humidity, desiccant temperature and concentration, and the area available for heat and mass transfer are of great interest. Due to the complexity of the dehumidification process, theoretical modeling relies heavily upon experimental studies. However, a limited number of experimental studies are reported in the literature. This paper presents results from a detailed experimental investigation of the heat and mass transfer between a liquid desiccant (triethylene glycol) and air in a packed bed absorption tower using high liquid flow rates. A high performance packing that combines good heat and mass transfer characteristics with low pressure drop is used. The rate of dehumidification, as well as the effectiveness of the dehumidification process are assessed based on the variables listed above. Good agreement is shown to exist between the experimental findings and predictions from finite difference modeling. In addition, a comparison between the findings in the present study and findings previously reported in the literature is made. The results obtained from this study make it possible to characterize the important variables which impact the system design.

Oeberg, V.; Goswami, D.Y. [Univ. of Florida, Gainesville, FL (United States)

1998-11-01T23:59:59.000Z

351

Development of a High Performance Air Source Heat Pump for the US Market  

SciTech Connect

Heat pumps present a significant advantage over conventional residential heating technologies due to higher energy efficiencies and less dependence on imported oil. The US development of heat pumps dates back to the 1930 s with pilot units being commercially available in the 1950 s. Reliable and cost competitive units were available in the US market by the 1960 s. The 1973 oil embargo led to increased interest in heat pumps prompting significant research to improve performance, particularly for cold climate locations. Recent increasing concerns on building energy efficiency and environmental emissions have prompted a new wave of research in heat pump technology with special emphasis on reducing performance degradation at colder outdoor air temperatures. A summary of the advantages and limitations of several performance improvement options sought for the development of high performance air source heat pump systems for cold climate applications is the primary focus of this paper. Some recommendations for a high performance cold climate heat pump system design most suitable for the US market are presented.

Abdelaziz, Omar [ORNL; Shen, Bo [ORNL; Gao, Zhiming [ORNL; Baxter, Van D [ORNL; Iu, Ipseng [ORNL

2011-01-01T23:59:59.000Z

352

Experimental study of an air-source heat pump for simultaneous heating and cooling Part 2: Dynamic behaviour and two-phase thermosiphon  

E-Print Network (OSTI)

from the heat stock previously produced. The air and water heat exchangers have to carry out. While producing hot water using the water condenser, the cold water tank is heated, usually from 5 to 15 during the winter sequence enables to produce hot water continuously with improved average system

353

Cold End Inserts for Process Gas Waste Heat Boilers Air Products, operates hydrogen production plants, which utilize large waste heat boilers (WHB)  

E-Print Network (OSTI)

Cold End Inserts for Process Gas Waste Heat Boilers Overview Air Products, operates hydrogen production plants, which utilize large waste heat boilers (WHB) to cool process syngas. The gas enters satisfies all 3 design criteria. ツキ Correlations relating our experimental results to a waste heat boiler

Demirel, Melik C.

354

The Earth-Coupled or Geothermal Heat Pump Air Conditioning System  

E-Print Network (OSTI)

As utility costs have risen despite political campaign promises and energy conserving measures implemented by the utility companies such as alternative fuel use (coal and nuclear), co-generation, etc., homeowners have begun to search for effective methods of reducing their electricity bills. In some cases homeowners are faced with utility bills That are approaching the cost of their mortgage payments. For those with fixed incomes, such as the elderly or those looking forward to retirement in the near future, this has become an alarming reality. Virtually every homeowner would like to reduce his utility bill but the question is, what items should he address in order to have a significant impact on his electricity costs? According to Houston Lighting h Power Company, 50% of an electricity bill can be attributed to the air conditioning system, and another 15-20% to the hot water heating system. Therefore, to dramatically reduce utility costs one should look first at these two "energy gulpers" and next at proper home insulation, window coverings, etc. The other electrical appliances in the home use relatively minor amounts of electricity compared to the air conditioning and hot water heating system. This paper will describe the geothermal heat pump and the desuperheater as the latest developments in energy efficient air conditioning and water heating.

Wagers, H. L.; Wagers, M. C.

1985-01-01T23:59:59.000Z

355

Field Measurements of Heating Efficiency of Electric Forced-Air Furnaces in Six Manufactured Homes.  

Science Conference Proceedings (OSTI)

This report presents the results of field measurements of heating efficiency for six manufactured homes in the Pacific Northwest heated with electric forced-air systems. This is the first in a series of regional and national efforts to measure in detail the heating efficiency of manufactured homes. Only six homes were included in this study because of budgetary constraints; therefore this is not a representative sample. These investigations do provide some useful information on the heating efficiency of these homes. Useful comparisons can be drawn between these study homes and site-built heating efficiencies measured with a similar protocol. The protocol used to test these homes is very similar to another Ecotope protocol used in the study conducted in 1992 and 1993 for the Bonneville Power Administration to test the heating efficiency of 24 homes. This protocol combined real-time power measurements of furnace energy usage with energy usage during co-heat periods. Accessory data such as house and duct tightness measurements and tracer gas measurements were used to describe these homes and their heating system efficiency. Ensuring that manufactured housing is constructed in an energy and resource efficient manner is of increasing concern to manufactured home builders and consumers. No comparable work has been done to measure the heating system efficiency of MCS manufactured homes, although some co-heat tests have been performed on manufactured homes heated with natural gas to validate HUD thermal standards. It is expected that later in 1994 more research of this kind will be conducted, and perhaps a less costly and less time-consuming method for testing efficiencies will be develops.

Davis, Bob; Palmiter, Larry S.; Siegel, Jeff

1994-07-26T23:59:59.000Z

356

Desiccant Enhanced Evaporative Air-Conditioning (DEVap): Evaluation of a New Concept in Ultra Efficient Air Conditioning  

SciTech Connect

NREL has developed the novel concept of a desiccant enhanced evaporative air conditioner (DEVap) with the objective of combining the benefits of liquid desiccant and evaporative cooling technologies into an innovative 'cooling core.' Liquid desiccant technologies have extraordinary dehumidification potential, but require an efficient cooling sink. DEVap's thermodynamic potential overcomes many shortcomings of standard refrigeration-based direct expansion cooling. DEVap decouples cooling and dehumidification performance, which results in independent temperature and humidity control. The energy input is largely switched away from electricity to low-grade thermal energy that can be sourced from fuels such as natural gas, waste heat, solar, or biofuels.

Kozubal, E.; Woods, J.; Burch, J.; Boranian, A.; Merrigan, T.

2011-01-01T23:59:59.000Z

357

Heat Controller: Proposed Penalty (2011-CE-1507) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Controller: Proposed Penalty (2011-CE-1507) Heat Controller: Proposed Penalty (2011-CE-1507) Heat Controller: Proposed Penalty (2011-CE-1507) April 22, 2011 DOE alleged in a Notice of Proposed Civil Penalty that Heat Controller, Inc. failed to certify a variety of room air conditioners as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. Heat Controller: Proposed Penalty (2011-CE-1507) More Documents & Publications Heat Controller: Order (2011-CE-1507)

358

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air  

NLE Websites -- All DOE Office Websites (Extended Search)

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners Title Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners Publication Type Report LBNL Report Number LBNL-63204 Year of Publication 2007 Authors McNeil, Michael A., and Maithili Iyer Date Published 03/2007 Keywords India Air Conditioner Efficiency Standards Abstract The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency.

359

Estimating Air亡ea Heat Fluxes in Semienclosed Basins: The Case of the Gulf of Elat (Aqaba)  

Science Conference Proceedings (OSTI)

Meteorological and oceanographic data collected at the head of the Gulf of Elat were used to compute the air穆ea heat flux components and the heat storage in the water column, which are in turn used to estimate the heat balance of this ...

Moshe Ben-Sasson; Steve Brenner; Nathan Paldor

2009-01-01T23:59:59.000Z

360

Air-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report  

Science Conference Proceedings (OSTI)

This report documents the development of an air-source integrated heat pump (AS-IHP) through the third quarter of FY2007. It describes the design, analyses and testing of the AS-IHP, and provides performance specifications for a field test prototype and proposed control strategy. The results obtained so far continue to support the AS-IHP being a promising candidate to meet the energy service needs for DOE's development of a Zero Energy Home (ZEH) by the year 2020.

Murphy, Richard W [ORNL; Rice, C Keith [ORNL; Baxter, Van D [ORNL; Craddick, William G [ORNL

2007-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Nuclear Maintenance Applications Center: Heating, Ventilating, and Air Conditioning Specialist Guide  

Science Conference Proceedings (OSTI)

The people responsible for heating, ventilating, and air conditioning (HVAC) in the nuclear power industry are known by various titles--HVAC specialist, HVAC component engineer, HVAC system manager, and HVAC system engineer, to name a few. Although HVAC duties and responsibilities are often spread across several departments, such as maintenance, operations, engineering, and procurement, it is up to the HVAC specialist to ensure that HVAC system and component health and reliability are maintained. This re...

2011-11-28T23:59:59.000Z

362

Performance Assessment of a Variable Refrigerant Flow Heat Pump Air Conditioning System  

Science Conference Proceedings (OSTI)

Variable refrigerant flow (VRF) technology uses smart integrated controls, variable speed drives, and refrigerant piping to provide energy efficiency, flexible operation, ease of installation, low noise, zone control, and comfort through all-electric technology. This report describes and documents the construction, performance, and application of a heat pump air conditioning system that uses VRF technology8212the Daikin VRV system. This variable refrigerant volume (VRV) system is manufactured by Daikin I...

2008-12-17T23:59:59.000Z

363

State-of-the-Art in Residential and Small Commercial Air HandlerPerformance  

SciTech Connect

Although furnaces, air conditioners, and heat pumps have become significantly more efficient over the last couple of decades, residential air handlers have typical efficiencies of only 10% to 15% due to poor electric motor and aerodynamic performance. These low efficiencies indicate that there is significant room for improvement of air handler fans. The other 85-90% of the electricity used by air handlers is manifested as heat. This extra heat reduces air conditioning cooling and dehumidification performance and effectively acts as fuel switching for fossil fueled furnaces. For electric furnaces, this heat substitutes directly for the electric resistance heating elements. For heat pumps, this heat substitutes for compressor-based high COP heating and effectively reduces the COP of the heat pump. Using a combination of field observations and engineering judgment they can assemble a list of the problems that lead to low air handler efficiency and potential solutions to these problems, as shown. None of the problems require exotic or complex solutions and there are no technological barriers to adopting them. Some of the solutions are simple equipment swaps (using better electric motors), others require changes to the way the components are built (tighter tolerances) and other relate to HVAC equipment design (not putting large fans in small cabinets).

Walker, Iain S.

2005-03-01T23:59:59.000Z

364

Model for determining modular heat recovery incinerator feasibility on air force installations. Master's thesis  

Science Conference Proceedings (OSTI)

This study constructed a model to determine the feasibility of building municipal solid waste (MSW) fired modular heat recovery incinerators (HRIs) on Air Force installations. The model consisted of three gates. Gate one identified current federal regulatory air emission requirements for various HRI pollutants. It also specified two air pollution control configurations with emission reduction efficiencies capable of achieving these requirements. Gate two presented a life-cycle cost (LCC) economic analysis methodology. Operational and cost data for existing modular HRIs located in the United States facilitated the development of regression equations that estimate capital and annual operating costs for a modular HRI. Actual cost and operational information from a central heating plant at Wright-Patterson AFB, along with cost data from the regression equations, provided the basis for an example LCC analysis involving modular HRIs Results of this hypothetical evaluation showed that the LCC for the modular HRI alternatives were both less than the LCC of replacing the existing boiler. Gate three presented a Likert-scale survey to evaluate the sociopolitical acceptability of the proposed HRI. The survey results indicate the level of effort to process the HRI proposal in accordance with the National Environmental Policy Act. Heat recovery, Incinerators, Waste management, Waste treatment.

Anderson, A.H.; Munnell, P.R.

1992-09-01T23:59:59.000Z

365

Air thermosiphon solar heating system: the Jones house, Santa Fe, New Mexico  

DOE Green Energy (OSTI)

A hybrid passive/active solar heating system, featuring a passive air thermosiphon loop, is described. Heated air is supplied to a rock storage bin, coupled with blower-driven air distribution to the house. The house, of 246 m/sup 2/ (2650 ft/sup 2/) heated area and located in Santa Fe, New Mexico, also includes a greenhouse located under the planar collector array. Architectural features and construction details of the house, the solar collector, storage, and distribution system are presented. Representative results of three months of monitoring by the Los Alamos Scientific Laboratory of collector, rock bin, and greenhouse temperatures, as well as outside ambient temperature and insolation, are reported and discussed. Data recorded hourly since the system was placed in operation in early February 1978, show temperatures in the rock bin in excess of 71/sup 0/C (160/sup 0/F) and in the collector absorber mesh in excess of 93/sup 0/C (200/sup 0/F). Delivery temperatures from the charged bin, without auxiliary boost, range from 38 to 54/sup 0/C (100 to 130/sup 0/F).

Hunn, B.D.; Jones, M.M.

1978-01-01T23:59:59.000Z

366

Effect of excess air on the optimization of heating appliances for biomass combustion  

Science Conference Proceedings (OSTI)

The performance of a domestic appliance for wood logs combustion is a function of several variables, such as the geometric design of the appliance and its operating parameters. Among them, air feeding conditions are really decisive if the objective function is the maximization of the heat recovered from flue gases. Therefore, even if pollutant emissions have to be ever considered, the amount of excess air can be seen as a fundamental parameter in the definition of thermal efficiency of the appliance. In this paper the role of this parameter is analysed. The analysis is conducted by linking the results obtained from experimental data, detailed CFD simulations and a simplified mathematical model based on a network of CSTR. The derivation of an idealized schematization of the appliance was essential to realize the role of excess air variations, with more generality than with respect to a specific appliance configuration. Conversely, while the experimental data and CFD results were necessary to derive the simplified model, the indications given by this simplified model were useful to analyze results coming from both experiments and detailed numerical simulations. It has been evidenced the need to distinguish between the role of excess air in the chemical combustion and in the heat recovery in the appliance as well as to quantify the feedback between these two processes. (author)

Menghini, D. [Dipartimento di Ingegneria Chimica, Universita degli studi di Napoli Federico II, Piazzale Tecchio 80, 80125 Napoli (Italy); Marra, F.S.; Allouis, C.; Beretta, F. [Consiglio Nazionale delle Ricerche, Istituto di Ricerche sulla Combustione - CNR, via Diocleziano 328, 80124 Napoli (Italy)

2008-07-15T23:59:59.000Z

367

Status report on survey of alternative heat pumping technologies  

SciTech Connect

The Department of Energy is studying alternative heat pumping technologies to identify possible cost effective alternatives to electric driven vapor compression heat pumps, air conditioners, and chillers that could help reduce CO{sub 2} emissions. Over thirty different technologies are being considered including: engine driven systems, fuel cell powered systems, and alternative cycles. Results presented include theoretical efficiencies for all systems as well as measured performance of some commercial, prototype, or experimental systems. Theoretical efficiencies show that the alternative electric-driven technologies would have HSPFs between 4 and 8 Btu/Wh (1.2 to 2.3 W/W) and SEERs between 3 and 9.5 Btu/Wh (0.9 and 2.8 W/W). Gas-fired heat pump technologies have theoretical seasonal heating gCOPs from 1.1 to 1.7 and cooling gCOPs from 0.95 to 1.6 (a SEER 12 Btu/Wh electric air conditioner has a primary energy efficiency of approximately 1.4 W/W).

Fischer, S.

1998-07-01T23:59:59.000Z

368

NREL: Technology Transfer - NREL Tests Advanced Air Conditioner ...  

The Coolerado H-80 easily surpassed the challenge's objective of exceeding DOE 2010 efficiency standards by 40%.

369

Variable Speed Fan Retrofits for Computer Room Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE))

Case study describes various concepts for more cost-effective cooling solutions in data centers, while keeping in mind that the reliability of computing systems and their respective cooling systems is always a key criterion.

370

NREL Solves Residential Window Air Conditioner Performance Limitations (Fact Sheet)  

SciTech Connect

Comprehensive performance tests lead to enhanced modeling capability and affordable methods to increase energy efficiency.

Not Available

2013-05-01T23:59:59.000Z

371

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network (OSTI)

of Energy, DRAFT Marginal Energy Prices Report, July, 1999.energy use by the energy price paid by the household.energy consumption, energy price, discount rate, and central

Rosenquist, G.

2010-01-01T23:59:59.000Z

372

Distribution substation load impacts of residential air conditioner load control  

SciTech Connect

An ongoing experiment to monitor the substation level load impacts of end-use load control is described. An overview of the data acquisition system, experimental procedures and analysis techniques are provided. Results of the 1983 and 1984 experiments demonstrate the value of aggregate load impact monitoring as a means of verifying load research results, calculating the diversity of end-use loads, and predicting the impacts of load management on the transmission and distribution systems.

Heffner, G.C.; Kaufman, D.A.

1985-07-01T23:59:59.000Z

373

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network (OSTI)

Richland, WA. Report No. PNNL- 7. U.S. Department of Energy,National Laboratory (PNNL) using the Building Loads andADL), and David Winiarski (PNNL). This work was supported by

Rosenquist, G.

2010-01-01T23:59:59.000Z

374

YMGI Through-the-Wall Air Conditioner Determined Noncompliant...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

testing revealed that this model operates at a Seasonal Energy Efficiency Rating (SEER) of 8.3. The current federal standard requires that through-the-wall split system...

375

Measuring Short-term Air Conditioner Demand Reductions for Operations...  

NLE Websites -- All DOE Office Websites (Extended Search)

frequently without affecting customer comfort. A key issue for grid operations and electricity market settlement is how to accurately measure shorter-term (e.g., ten's of...

376

Laboratory Performance Testing of Residential Window Mounted Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was delivered at the U.S. Department of Energy Building America Technical Update meeting on April 29-30, 2013, in Denver, Colorado.

377

Air Conditioner Efficiency Under Hot Dry and Hot Humid Conditions  

Science Conference Proceedings (OSTI)

The seasonal energy efficiency ratio (or SEER) has been the subject of extensive research, development, use, and revision for over 30 years. This report gives a review of the past, present, and future of SEER. This review is needed to provide a common background and perspective in response to a move away from one national standard to three standards. Recommendations are made for what electric utilities can do in response to the challenges and opportunities presented by regional climate-sensitive SEERs.

2008-06-23T23:59:59.000Z

378

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network (OSTI)

for major household appliances. Any new or amended standardcosts), lifetime of the appliance, and a discount rate. LCCconsumers use in purchasing appliances. Consumers purchase

Rosenquist, G.

2010-01-01T23:59:59.000Z

379

Magnetic Refrigeration Technology for High Efficiency Air Conditioning  

SciTech Connect

Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate heat exchangers or oil distribution issues found in traditional vapor compression systems.

Boeder, A; Zimm, C

2006-09-30T23:59:59.000Z

380

Energy Saving Potentials and Air Quality Benefits of Urban HeatIslandMitigation  

SciTech Connect

Urban areas tend to have higher air temperatures than their rural surroundings as a result of gradual surface modifications that include replacing the natural vegetation with buildings and roads. The term ''Urban Heat Island'' describes this phenomenon. The surfaces of buildings and pavements absorb solar radiation and become extremely hot, which in turn warm the surrounding air. Cities that have been ''paved over'' do not receive the benefit of the natural cooling effect of vegetation. As the air temperature rises, so does the demand for air-conditioning (a/c). This leads to higher emissions from power plants, as well as increased smog formation as a result of warmer temperatures. In the United States, we have found that this increase in air temperature is responsible for 5-10% of urban peak electric demand for a/c use, and as much as 20% of population-weighted smog concentrations in urban areas. Simple ways to cool the cities are the use of reflective surfaces (rooftops and pavements) and planting of urban vegetation. On a large scale, the evapotranspiration from vegetation and increased reflection of incoming solar radiation by reflective surfaces will cool a community a few degrees in the summer. As an example, computer simulations for Los Angeles, CA show that resurfacing about two-third of the pavements and rooftops with reflective surfaces and planting three trees per house can cool down LA by an average of 2-3K. This reduction in air temperature will reduce urban smog exposure in the LA basin by roughly the same amount as removing the basin entire onroad vehicle exhaust. Heat island mitigation is an effective air pollution control strategy, more than paying for itself in cooling energy cost savings. We estimate that the cooling energy savings in U.S. from cool surfaces and shade trees, when fully implemented, is about $5 billion per year (about $100 per air-conditioned house).

Akbari, Hashem

2005-08-23T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

New Insights into the Ocean Heat Budget Closure Problem from Analysis of the SOC Air亡ea Flux Climatology  

Science Conference Proceedings (OSTI)

Results from an analysis of the Southampton Oceanography Centre (SOC) global air穆ea heat flux climatology, which has been calculated using in situ weather reports from voluntary observing ships covering the period 198093, are presented. ...

Simon A. Josey; Elizabeth C. Kent; Peter K. Taylor

1999-09-01T23:59:59.000Z

382

Estimating Regional Surface Heat and Moisture Fluxes above Prairie Cropland from Surface and Upper-Air Measurements  

Science Conference Proceedings (OSTI)

Upper-air budget methods can be used to estimate the surface sensible and latent heat flux densities on a regional scale. This study assesses the application of radiosonde-based budget methods above homogeneous cropland. Serial daytime soundings ...

Alan G. Barr; G. S. Strong

1996-10-01T23:59:59.000Z

383

Fine Adjustment of Large Scale Air-Sea Energy Flux Parameterizations by Direct Estimates of Ocean Heat Transport  

Science Conference Proceedings (OSTI)

An inverse technique is used to adjust uncertain coefficients and parameters in the bulk formulae of climatological air-sea energy fluxes in order to obtain an agreement of indirect estimates of meridional heat transport with direct estimates in ...

Hans-Jrg Isemer; Jrgen Willebrand; Lutz Hasse

1989-10-01T23:59:59.000Z

384

Opportunities for Saving Energy and Improving Air Quality in Urban Heat Islands  

E-Print Network (OSTI)

Refrigeration, and Air conditioning Engineers, Atlanta,Refrigeration, and Air Conditioning Engineers, Atlanta,Refrigeration, and Air Conditioning Engineers, Atlanta,

Akbari, Hashem

2008-01-01T23:59:59.000Z

385

A genetic rule weighting and selection process for fuzzy control of heating, ventilating and air conditioning systems  

Science Conference Proceedings (OSTI)

In this paper, we propose the use of weighted linguistic fuzzy rules in combination with a rule selection process to develop accurate fuzzy logic controllers dedicated to the intelligent control of heating, ventilating and air conditioning systems concerning ... Keywords: BEMS, building energy management system, FLC, fuzzy logic controller, Fuzzy logic controllers, GA, genetic algorithm, Genetic algorithms, HVAC systems, HVAC, heating, ventilating, and air conditioning, KB, knowledge base, PMV, predicted mean vote index for thermal comfort, Rule selection, Weighted fuzzy rules

Rafael Alcal; Jorge Casillas; Oscar Cordn; Antonio Gonz疝ez; Francisco Herrera

2005-04-01T23:59:59.000Z

386

2003 status report savings estimates for the energy star(R) voluntary labeling program  

E-Print Network (OSTI)

for Carbon Heat Rate Oil Price Source b Electricity SourceGas or Oil) -Central Air Conditioner -Air-Source Heat Pump -Gas or Oil) - Central Air Conditioners - Air-Source Heat

Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla

2004-01-01T23:59:59.000Z

387

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 2, Fluorescent lamp ballasts, television sets, room air conditioners, and kitchen ranges and ovens  

SciTech Connect

This document is divided into ``volumes`` B through E, dealing with individual classes of consumer products. Chapters in each present engineering analysis, base case forecasts, projected national impacts of standards, life-cycle costs and payback periods, impacts on manufacturers, impacts of standards on electric utilities, and environmental effects. Supporting appendices are included.

Not Available

1993-11-01T23:59:59.000Z

388

Simulations of sizing and comfort improvements for residential forced-air heating and cooling systems  

SciTech Connect

In many parts of North America residential HVAC systems are installed outside conditioned space. This leads to significant energy losses and poor occupant comfort due to conduction and air leakage losses from the air distribution ducts. In addition, cooling equipment performance is sensitive to air flow and refrigerant charge that have been found to be far from manufacturers specifications in most systems. The simulation techniques discussed in this report were developed in an effort to provide guidance on the savings potentials and comfort gains that can be achieved by improving ducts (sealing air leaks) and equipment (correct air-flow and refrigerant charge). The simulations include the complex air flow and thermal interactions between duct systems, their surroundings and the conditioned space. They also include cooling equipment response to air flow and refrigerant charge effects. Another key aspect of the simulations is that they are dynamic to account for cyclic losses from the HVAC system and the effect of cycle length on energy and comfort performance. To field test the effect of changes to residential HVAC systems requires extensive measurements to be made for several months for each condition tested. This level of testing is often impractical due to cost and time limitations. Therefore the Energy Performance of Buildings Group at LBNL developed a computer simulation tool that models residential HVAC system performance. This simulation tool has been used to answer questions about equipment downsizing, duct improvements, control strategies and climate variation so that recommendations can be made for changes in residential construction and HVAC installation techniques that would save energy, reduce peak demand and result in more comfortable homes. Although this study focuses on California climates, the simulation tool could easily be applied to other climates. This report summarizes the simulation tool and discusses the significant developments that allow the use of this tool to perform detailed residential HVAC system simulations. The simulations have been verified by comparison to measured results in several houses over a wide range of weather conditions and HVAC system performance. After the verification was completed, more than 350 cooling and 450 heating simulations were performed. These simulations covered a range of HVAC system performance parameters and California climate conditions (that range from hot dry deserts to cold mountain regions). The results of the simulations were used to show the large increases in HVAC system performance that can be attained by improving the HVAC duct distribution systems and by better sizing of residential HVAC equipment. The simulations demonstrated that improved systems can deliver improved heating or cooling to the conditioned space, maintain equal or better comfort while reducing peak demand and the installed equipment capacity (and therefore capital costs).

Walker, I.S.; Degenetais, G.; Siegel, J.A.

2002-05-01T23:59:59.000Z

389

Outdoor Air, Heat Wheels and JCPenney: A New Approach to Retail Ventilation  

E-Print Network (OSTI)

JCPenney Construction Services department is responsible for the construction of new stores, takeover of existing facilities to create a new store, repairs to existing JCPenney facilities and the expansion and modernization of stores across the nation and the world. Each year, JCPenney Construction Services handles approximately 50 projects along these lines. After the implementation of ASHRAE 62- 1989 by JCPenney and many major building codes, including BOCA, mechanical engineers at JCPenney noticed a sharp increase in the percentage of cooling capacity required to cool the outdoor ventilation air. In an effort to limit this impact, both in first cost and in operational costs, JCPenney is beginning to make an effort to use enthalpy heat wheels in the hot and humid climate areas where it is economically feasible. This paper discusses the efforts of JCPenney to implement this option to the treatment of outdoor air in a store in Baton Rouge, LA while maintaining indoor air quality requirements as stated in ASHRAE Standard 62-1989 and maintaining energy efficiency. This paper also discusses the projected energy savings and operations of this alternative to the standard treatment of outdoor air.

Smith, C. S.; Bartlett, T. A.

1998-01-01T23:59:59.000Z

390

How refrigeration, heating, ventilation, and air conditioning service technicians learn from troubleshooting (Dissertation ABstract)  

E-Print Network (OSTI)

The purpose of this study was to understand how refrigeration, heating, ventilation, and air conditioning (RHVAC) service technicians (techs) learned from troubleshooting. This understanding resulted in instructional and curricular strategies designed to help community colleges prepare vocational students to learn more effectively from informal workplace learning. RHVAC techs were studied because they increasingly learn their trade skills through a combination of formal schooling and informal workplace learning, though many still learn their trade almost exclusively in the workplace. Even those with formal training require considerable workplace experience to become fully competent. Troubleshooting is a major job function for RHVAC service techs, and troubleshooting

Denis F. H. Green

2006-01-01T23:59:59.000Z

391

Application of the VRV Air-Conditioning System Heat Recovery Series in Interior Zone and Analysis of its Energy Saving  

E-Print Network (OSTI)

To reduce the energy consumption of air conditioning systems, we can use the VRV air conditioning system to supply cold loads in the winter for rooms in the construction inner zone where cold loads need to be supplied. The VRV air-conditioning system of variable frequency technology can achieve the effect of energy conservation. In this article, we analyze the application of the VRV air conditioning system heat recovery series in the construction inner zone and its energy saving characteristics via a project example.

Zhang, Q.; Li, D.; Zhang, J.

2006-01-01T23:59:59.000Z

392

Evaluation of a residential solar air heating system. Interim progress report, August 1976--May 1977. [Comparison of air-type and liquid-type collectors  

SciTech Connect

The comparative performance of Solar House II collectors (air heater) and Solar House I collectors (liquid heater) is presented. In the 1976 comparison year, there is no conclusive evidence that either system provides a greater fraction of the seasonal load. Both systems were designed to provide approximately 75 percent of the annual space and water heating load, and the design targets are reasonably achieved. In February, 1976, the air system provided 65 percent of the total requirement while the liquid system provided 76 percent. In March, based on a few days of data, the performance was substantially the same. In April the air system provided a greater fraction of solar heat to the total need, but the use of the heat was different, more being used for domestic water heating in Solar House I than in Solar House II. The data for 1977 have not yet been fully analyzed for both solar houses and therefore, a complete comparison cannot be made. At this stage in the evaluations, it can be stated that either system can be designed to achieve the target fraction of the total annual heat requirements. (WHK)

Karaki, S.

1977-05-01T23:59:59.000Z

393

Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes  

SciTech Connect

Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

Backman, C.; German, A.; Dakin, B.; Springer, D.

2013-12-01T23:59:59.000Z

394

Field Test of High Efficiency Residential Buildings with Ground-source and Air-source Heat Pump Systems  

SciTech Connect

This paper describes the field performance of space conditioning and water heating equipment in four single-family residential structures with advanced thermal envelopes. Each structure features a different, advanced thermal envelope design: structural insulated panel (SIP); optimum value framing (OVF); insulation with embedded phase change materials (PCM) for thermal storage; and exterior insulation finish system (EIFS). Three of the homes feature ground-source heat pumps (GSHPs) for space conditioning and water heating while the fourth has a two-capacity air-source heat pump (ASHP) and a heat pump water heater (HPWH). Two of the GCHP-equipped homes feature horizontal ground heat exchange (GHX) loops that utillize the existing foundation and utility service trenches while the third features a vertical borehole with vertical u-tube GHX. All of the houses were operated under the same simulated occupancy conditions. Operational data on the house HVAC/Water heating (WH) systems are presented and factors influencing overall performance are summarized.

Ally, Moonis Raza [ORNL; Munk, Jeffrey D [ORNL; Baxter, Van D [ORNL

2011-01-01T23:59:59.000Z

395

2007 Status Report: Savings Estimates for the ENERGY STAR(R) VoluntaryLabeling Program  

E-Print Network (OSTI)

Gas Price MBtu Oil Price MBtu Price Source c d e f g h i j jGas or Oil) - Central Air Conditioner - Air-Source HeatGas or Oil) - Central Air Conditioner - Air-Source Heat

Sanchez, Marla; Webber, Carrie A.; Brown, Richard E.; Homan, Gregory K.

2007-01-01T23:59:59.000Z

396

2005 Status Report Savings Estimates for the ENERGY STAR(R) Voluntary Labeling Program  

E-Print Network (OSTI)

Rate Electricit Carbon Oil Price Source b Source Rate SourceGas or Oil) - Central Air Conditioner - Air-Source HeatGas or Oil) - Central Air Conditioners - Air-Source Heat

Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla

2006-01-01T23:59:59.000Z

397

2006 Status Report Savings Estimates for the ENERGY STAR(R) Voluntary Labeling Program  

E-Print Network (OSTI)

Gas Price MBtu Oil Price MBtu Price Source Carbon EmissionsGas or Oil) - Central Air Conditioner - Air-Source HeatGas or Oil) - Central Air Conditioner - Air-Source Heat

Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla; Homan, Gregory K.

2006-01-01T23:59:59.000Z

398

2002 status report: Savings estimates for the ENERGY STAR(R) voluntary labeling program  

E-Print Network (OSTI)

for Carbon Source Rate Oil Price Source b Electricity SourceGas or Oil) -Central Air Conditioner -Air-Source Heat Pump -Gas or Oil) - Central Air Conditioners - Air-Source Heat

Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla; Koomey, Jonathan

2003-01-01T23:59:59.000Z

399

Calendar Year 2009 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network (OSTI)

Res. Gas Price Oil Price Price Sources Elec. Carbon EmissionGas or Oil) Central Air Conditioner Air-Source Heat PumpGas or Oil) Central Air Conditioner Air-Source Heat Pump

Homan, Gregory K

2011-01-01T23:59:59.000Z

400

Calendar Year 2008 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network (OSTI)

Res. Gas Price Oil Price Price Sources Elec. Carbon EmissionGas or Oil) Central Air Conditioner Air-Source Heat PumpGas or Oil) Central Air Conditioner Air-Source Heat Pump

Homan, GregoryK

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Calendar Year 2007 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network (OSTI)

Price MBtu Oil Price $/MBtu Price Sources, US DOE 3 CarbonGas or Oil) - Central Air Conditioner - Air-Source HeatGas or Oil) - Central Air Conditioner - Air-Source Heat

Sanchez, Marla Christine

2008-01-01T23:59:59.000Z

402

Savings estimates for the ENERGY STAR (registered trademark) voluntary labeling program: 2001 status report  

E-Print Network (OSTI)

Gas Price MBtu Oil Price MBtu Price Source The followingGas or Oil) -Central Air Conditioner -Air-Source Heat Pump -Gas or Oil) - Central Air Conditioners - Air-Source Heat

Webber, Carrie A.; Brown, Richard E.; Mahajan, Akshay; Koomey, Jonathan G.

2002-01-01T23:59:59.000Z

403

2004 status report: Savings estimates for the Energy Star(R) voluntarylabeling program  

E-Print Network (OSTI)

Rate Electricit Carbon Oil Price Source b Source Rate SourceGas or Oil) -Central Air Conditioner -Air-Source Heat Pump -Gas or Oil) - Central Air Conditioners - Air-Source Heat

Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla

2004-01-01T23:59:59.000Z

404

Buildings Energy Data Book: 5.3 Heating, Cooling, and Ventilation Equipment  

Buildings Energy Data Book (EERE)

U.S. Heating and Air-Conditioning System Manufacturer Shipments, by Type (Including Exports) 2005 Value of 2000 2005 2007 2009 2010 Shipments Equipment Type (1,000s) (1,000s) (1,000s) (1,000s) (1,000s) ($million) (7) Air-Conditioners (1) 5,346 6,472 4,508 3,516 3419 5,837 Heat Pumps 1,539 2,336 1,899 1,642 1,748 2,226 Air-to-Air Heat Pumps 1,339 2,114 1,899 1,642 1748 1,869 Water-Source Heat Pumps (2) 200 222 N.A. N.A. N.A. 357 Chillers 38 37 37 25 29 1,093 Reciprocating 25 24 30 20 24 462 Centrifugal/Screw 8 6 7 5 5 566 Absorption (3) 5 7 N.A. N.A. N.A. 64 Furnaces 3,681 3,624 2,866 2,231 2,509 2,144 Gas-Fired (4) 3,104 3,512 2,782 2,175 2453 2,081 Electric 455 N.A. N.A. N.A. N.A. N.A. Oil-Fired (5) 121 111 84 56 56 63 Boilers (6) 368 370 N.A. N.A. N.A. N.A. Note(s): Source(s): 1) Includes exports and gas air conditioners (gas units <10,000 units/yr) and rooftop equipment. Excludes heat pumps, packaged terminal air

405

Design and Analysis of High-Performance Air-Cooled Heat Exchanger with an Integrated Capillary-Pumped Loop Heat Pipe  

E-Print Network (OSTI)

We report the design and analysis of a high-power air-cooled heat exchanger capable of dissipating over 1000 W with 33 W of input electrical power and an overall thermal resistance of less than 0.05 K/W. The novelty of the ...

McCarthy, Matthew

406

Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)  

SciTech Connect

This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

Kozubal, E.

2013-02-01T23:59:59.000Z

407

DOE/EA-1673: Environmental Assessment for Energy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards and Test Procedures for Commercial Heating, Air-Conditioning, and Water-Heating Equipment (July 2009)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3 3 Environmental Assessment for 10 CFR 431 Energy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards and Test Procedures for Commercial Heating, Air- Conditioning, and Water-Heating Equipment July 2009 8-i CHAPTER 8. ENVIRONMENTAL ASSESSMENT TABLE OF CONTENTS 8.1 INTRODUCTION ............................................................................................................... 8-1 8.2 AIR QUALITY ANALYSIS ............................................................................................... 8-1 8.3 AIR POLLUTANT DESCRIPTIONS ................................................................................ 8-1 8.4 AIR QUALITY REGULATIONS ...................................................................................... 8-3

408

Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure  

E-Print Network (OSTI)

Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure

2012-01-01T23:59:59.000Z

409

Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel  

E-Print Network (OSTI)

Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel

2012-01-01T23:59:59.000Z

410

Comparative performance of solar heating with air and liquid systems. Interim progress report, February 1, 1976--August 30, 1976  

SciTech Connect

A performance comparison between an air solar system and a liquid solar system for space heating under nearly equal conditions has been obtained. The Colorado State University Solar House I is a liquid solar system which has been in operation since August 1974. Solar House II, which stands adjacent to and has a comparable heating load to Solar House I, is equipped with an air solar system. Solar House I has been continuously monitored since August 1974 and Solar House II has been monitored since February 1976. Performance of the solar systems is reported in terms of the collector efficiency, the amount of space heating and service water heating load provided by solar energy, and the use of electrical energy to operate the solar equipment. General characteristics of the two types of systems are also compared. Information concerning installation, operation, and maintenance of the systems have been documented and are discussed.

Karaki, S.; Lof, G.O.G.; Smith, C.C.

1976-08-01T23:59:59.000Z

411

Research and design work on heat emission and aerodynamic resistance of tube bundles in air cooling equipment  

SciTech Connect

Results of studies of heat emission using methods of local and global thermal simulation of crossflow small-array bundles of tubes finned with wound aluminum strip, and flared into the load-bearing wall, are reported. Correction factors applicable to the method of simulating convective heat transfer over the range Re = (2.5-25).10/sup 3/ are given, with variation in the number of rows over the air course from one to four.

Kuntysh, V.B.; Fedotova, L.M.

1983-01-01T23:59:59.000Z

412

Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems  

DOE Green Energy (OSTI)

This paper presents a freely available Modelica library for building heating, ventilation and air conditioning systems. The library is based on the Modelica.Fluid library. It has been developed to support research and development of integrated building energy and control systems. The primary applications are controls design, energy analysis and model-based operation. The library contains dynamic and steady-state component models that are applicable for analyzing fast transients when designing control algorithms and for conducting annual simulations when assessing energy performance. For most models, dimensional analysis is used to compute the performance for operating points that differ from nominal conditions. This allows parameterizing models in the absence of detailed geometrical information which is often impractical to obtain during the conceptual design phase of building systems. In the first part of this paper, the library architecture and the main classes are described. In the second part, an example is presented in which we implemented a model of a hydronic heating system with thermostatic radiator valves and thermal energy storage.

Wetter, Michael

2009-06-17T23:59:59.000Z

413

Energy Basics: Heat Pump Systems  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Systems Air-Source Heat Pumps Ductless Mini-Split Heat Pumps Absorption Heat Pumps Geothermal Heat Pumps Supporting Equipment for Heating & Cooling Systems Water Heating Heat...

414

List of Heat pumps Incentives | Open Energy Information  

Open Energy Info (EERE)

pumps Incentives pumps Incentives (Redirected from List of Heat Pumps Incentives) Jump to: navigation, search The following contains the list of 1213 Heat pumps Incentives. CSV (rows 1-500) CSV (rows 501-1000) CSV (rows 1001-1213) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP (Central and North) - CitySmart Program (Texas) Utility Rebate Program Texas Commercial Industrial Institutional Local Government Schools Boilers Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Furnaces Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Roofs Windows Yes AEP (Central and SWEPCO) - Coolsaver A/C Tune Up (Texas) Utility Rebate Program Texas Commercial

415

Alliant Energy Interstate Power and Light (Electric) - Residential...  

Open Energy Info (EERE)

Heat pumps, Lighting, Programmable Thermostats, Refrigerators, Water Heaters, Windows, Room Air Conditioners, Geothermal Heat Pumps, Appliance Recycling, Home Energy...

416

Apartment and Condo New Construction Efficiency Services | Open...  

Open Energy Info (EERE)

Insulation, Central Air conditioners, Clothes Washers, Dehumidifiers, Dishwasher, Energy Mgmt. SystemsBuilding Controls, Equipment Insulation, Furnaces, Heat pumps, Heat...

417

Building and Fire Publications  

Science Conference Proceedings (OSTI)

... heat exchanger. Simulation of Heat Exchangers of a Window Air Conditioner Retrofitted With R-407C. IRC0048;International ...

418

Duct Systems in large commercial buildings: Physical characterization, air leakage, and heat conduction gains  

E-Print Network (OSTI)

A variety of methods of sealing supply-air registers wereand sealing practices when leakage at connections to duct-mounted equipment is not considered. The measured air-

Fisk, W.J.

2011-01-01T23:59:59.000Z

419

Forced convective flow and heat transfer of upward cocurrent air-water slug flow in vertical plain and swirl tubes  

SciTech Connect

This experimental study comparatively examined the two-phase flow structures, pressured drops and heat transfer performances for the cocurrent air-water slug flows in the vertical tubes with and without the spiky twisted tape insert. The two-phase flow structures in the plain and swirl tubes were imaged using the computerized high frame-rate videography with the Taylor bubble velocity measured. Superficial liquid Reynolds number (Re{sub L}) and air-to-water mass flow ratio (AW), which were respectively in the ranges of 4000-10000 and 0.003-0.02 were selected as the controlling parameters to specify the flow condition and derive the heat transfer correlations. Tube-wise averaged void fraction and Taylor bubble velocity were well correlated by the modified drift flux models for both plain and swirl tubes at the slug flow condition. A set of selected data obtained from the plain and swirl tubes was comparatively examined to highlight the impacts of the spiky twisted tape on the air-water interfacial structure and the pressure drop and heat transfer performances. Empirical heat transfer correlations that permitted the evaluation of individual and interdependent Re{sub L} and AW impacts on heat transfer in the developed flow regions of the plain and swirl tubes at the slug flow condition were derived. (author)

Chang, Shyy Woei [Thermal Fluids Laboratory, National Kaohsiung Marine University, No. 142, Haijhuan Road, Nanzih District, Kaohsiung City 81143 (China); Yang, Tsun Lirng [Department of Marine Engineering, National Kaohsiung Marine University, No. 142, Haijhuan Road, Nanzih District, Kaohsiung City 81143 (China)

2009-10-15T23:59:59.000Z

420

City of Tallahassee Utilities - Efficiency Loans (Florida) |...  

Open Energy Info (EERE)

Doors, DuctAir sealing, Heat pumps, Heat recovery, Pool Pumps, Refrigerators, Roofs, Windows, Room Air Conditioners, Geothermal Heat Pumps, Water Source Heat Pump Active...

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Troubleshooting the residential air conditioning system  

Science Conference Proceedings (OSTI)

In order to effectively diagnose problems in a residential air conditioning system, the technician should develop and follow a logical step-by-step troubleshooting procedure. A list of problems, along with possible causes and solutions, that a technician may encounter when servicing a residential air conditioner is presented.

Puzio, H. [Sussex County Vocational Technical School, Sparta, NJ (United States)

1996-01-01T23:59:59.000Z

422

A multi-objective evolutionary algorithm for an effective tuning of fuzzy logic controllers in heating, ventilating and air conditioning systems  

Science Conference Proceedings (OSTI)

This paper focuses on the use of multi-objective evolutionary algorithms to develop smartly tuned fuzzy logic controllers dedicated to the control of heating, ventilating and air conditioning systems, energy performance, stability and indoor comfort ... Keywords: Fuzzy logic controllers, Genetic tuning, HVAC systems, Heating, ventilating, and air conditioning systems, Linguistic 2-tuples representation, Multi-objective evolutionary algorithms, Rule selection

Mara Jos Gacto; Rafael Alcal; Francisco Herrera

2012-03-01T23:59:59.000Z

423

AN EXPERIMENTAL INVESTIGATION ON HEAT TRANSFER CHARACTERISTICS OF AIR AND CO2 IN MICROTUBES  

E-Print Network (OSTI)

by a cooling capacity, which is delivered in those rooms by heat exchangers where a heat transfer fluid - 2 and Fluid Science, 1-3:17. Mortada S., 2010. "Heat transfer performance of a mini-channel evaporator are mini-channel heat exchangers (MCHE) combining high heat transfer coefficients and low refrigerant

Kandlikar, Satish

424

Preheated Combustion Air (International Fact Sheet), Energy Tips-Process Heating, Process Heating Tip Sheet #1c  

Science Conference Proceedings (OSTI)

This English/Chinese international tip sheet provides information for optimizing industrial process heating systems and includes measurements in metric units.

Not Available

2010-10-01T23:59:59.000Z

425

Check Burner Air to Fuel Ratios (International Fact Sheet), Energy Tips-Process Heating, Process Heating Tip Sheet #2c  

Science Conference Proceedings (OSTI)

This English/Chinese international tip sheet provides information for optimizing efficiency of industrial process heating systems and includes measurements in metric units.

Not Available

2010-10-01T23:59:59.000Z

426

Table Contents Page i 2013 Nonresidential Compliance Manual January 2014  

E-Print Network (OSTI)

Table B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods.....................................................3 Table C-1...........................................4 Table E-1 Gas and Oil Space Heater Test Methods

427

A P P L I A N C E EFFICIENCY REGULATIONS  

E-Print Network (OSTI)

Test Methods...........................40 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods ......................41 C.....................................................................................42 E-1 Gas and Oil Space Heater Test Methods

428

A P P L I A N C E August, 2003  

E-Print Network (OSTI)

Test Methods........................... 40 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods....................... 41 C ...................................................................................... 42 E-1 Gas and Oil Space Heater Test Methods

429

Building Technologies Office: Current Test Procedure Waivers  

NLE Websites -- All DOE Office Websites (Extended Search)

2805 72FR71387 121707 Air Conditioners and Heat Pumps, Residential Multi-zone Unitary Small Air Conditioners and Heat Pumps ECR International, Inc. 78FR47681 080613 Heat Pump...

430

MidAmerican Energy (Electric) - Residential Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Conditioners: 25 Central Air Conditioners: 100-200 Heat Pumps: 100-400 Ground-source Heat Pumps: 1000-2000 Desuperheaters: 100 Heat Pump Water Heaters: 100 Water...

431

DOE Requires Air-Con International to Cease Sales of Inefficient Air  

NLE Websites -- All DOE Office Websites (Extended Search)

Requires Air-Con International to Cease Sales of Inefficient Requires Air-Con International to Cease Sales of Inefficient Air Conditioners and Proposes Penalties DOE Requires Air-Con International to Cease Sales of Inefficient Air Conditioners and Proposes Penalties September 21, 2010 - 6:43pm Addthis The Department has issued a Notice of Noncompliance Determination and Proposed Civil Penalty to Air-Con, International, requiring Air-Con to cease the sale of certain air-conditioning systems in the United States and proposing a civil penalty of $231,090 for sales of these products in violation of the applicable energy efficiency standards. This action reflects the Department's continued commitment to act aggressively to remove unlawful products from the market. In March, 2010, the Department issued a subpoena requiring Air-Con to

432

Estimation of Sensible and Latent Heat Fluxes from Soil Surface Temperature Using a Linear Air-Land Heat Transfer Model  

Science Conference Proceedings (OSTI)

The authors present a linearized model of the heat transfer between the soil layer and the atmosphere. Using this model, the moisture availability at the surface can be estimated from the diurnal variations of the soil surface temperature and ...

Fujio Kimura; Yugo Shimizu

1994-04-01T23:59:59.000Z

433

Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences  

SciTech Connect

The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the reheat coil adds additional heat to maintain the supply air temperature close to the return air temperature (100% latent cooling). Project Outcomes Key Phase II objectives were to develop a pre-production version of the system and to demonstrate its performance in an actual house. The system was first tested in the laboratory and subsequently underwent field-testing at a new house in Gainesville, Florida. Field testing began in 2006 with monitoring of a 'conventional best practices' system that included a two stage air conditioner and Energy Star dehumidifier. In September 2007, the I-HVCD components were installed for testing. Both systems maintained uniform indoor temperatures, but indoor RH control was considerably better with the I-HVCD system. The daily variation from average indoor humidity conditions was less than 2% for the I-HVCD vs. 5-7% for the base case system. Data showed that the energy use of the two systems was comparable. Preliminary installed cost estimates suggest that production costs for the current I-HVCD integrated design would likely be lower than for competing systems that include a high efficiency air conditioner, dehumidifier, and fresh air ventilation system. Project Benefits This project verified that the I-HVCD refrigeration compacts are compact (for easy installation and retrofit) and can be installed with air conditioning equipment from a variety of manufacturers. Project results confirmed that the system can provide precise indoor temperature and RH control under a variety of climate conditions. The I-HVCD integrated approach offers numerous benefits including integrated control, easier installation, and reduced equipment maintenance needs. Work completed under this project represents a significant step towards product commercialization. Improved indoor RH control and fresh air ventilation are system attributes that will become increasingly important in the years ahead as building envelopes improve and sensible cooling loads continue to fall. Technologies like I-HVCD will be instrumental in meeting goals set by Building America

Hoeschele, M.A.; D.A. Springer

2008-06-18T23:59:59.000Z

434

Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences  

Science Conference Proceedings (OSTI)

The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the reheat coil adds additional heat to maintain the supply air temperature close to the return air temperature (100% latent cooling). Project Outcomes Key Phase II objectives were to develop a pre-production version of the system and to demonstrate its performance in an actual house. The system was first tested in the laboratory and subsequently underwent field-testing at a new house in Gainesville, Florida. Field testing began in 2006 with monitoring of a 'conventional best practices' system that included a two stage air conditioner and Energy Star dehumidifier. In September 2007, the I-HVCD components were installed for testing. Both systems maintained uniform indoor temperatures, but indoor RH control was considerably better with the I-HVCD system. The daily variation from average indoor humidity conditions was less than 2% for the I-HVCD vs. 5-7% for the base case system. Data showed that the energy use of the two systems was comparable. Preliminary installed cost estimates suggest that production costs for the current I-HVCD integrated design would likely be lower than for competing systems that include a high efficiency air conditioner, dehumidifier, and fresh air ventilation system. Project Benefits This project verified that the I-HVCD refrigeration compacts are compact (for easy installation and retrofit) and can be installed with air conditioning equipment from a variety of manufacturers. Project results confirmed that the system can provide precise indoor temperature and RH control under a variety of climate conditions. The I-HVCD integrated approach offers numerous benefits including integrated control, easier installation, and reduced equipment maintenance needs. Work completed under this project represents a significant step towards product commercialization. Improved indoor RH control and fresh air ventilation are system attributes that will become increasingly important in the years ahead as building envelopes improve and sensible cooling loads continue to fall. Technologies like I-HVCD will be instrumental in meeting goals set by Building America

Hoeschele, M.A.; D.A. Springer

2008-06-18T23:59:59.000Z

435

Energy Basics: Absorption Heat Pumps  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Systems Air-Source Heat Pumps Ductless Mini-Split Heat Pumps Absorption Heat Pumps Geothermal Heat Pumps Supporting Equipment for Heating & Cooling Systems Water Heating...

436

Energy Basics: Geothermal Heat Pumps  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Systems Air-Source Heat Pumps Ductless Mini-Split Heat Pumps Absorption Heat Pumps Geothermal Heat Pumps Supporting Equipment for Heating & Cooling Systems Water Heating...

437

Energy Consumption Simulation and Analysis of Heat Pump Air Conditioning System in Wuhan by the BIN Method  

E-Print Network (OSTI)

Based on the weather data of a standard year in Wuhan, derived from the data of the latest 15 years, the data for the BIN (temperature and humidity frequency) method of an annual and 8-hour system were calculated. Then the BIN method was adopted to simulate the annual energy consumption of groundwater heat pump systems (GWHPS) for an office building in Wuhan. Its annual energy consumption was obtained and compared with the partner of the air source heat pump systems (ASHPS). The results show that the energy consumption of the former was approximately less 23.3% than that of the latter in summer and 19.1% in winter.

Wen, Y.; Zhao, F.

2006-01-01T23:59:59.000Z

438

DOE/ORNL heat pump design model, overview and application to R-22 alternatives  

SciTech Connect

This computer program is a public-domain system design tool for application to air-to-air heat pumps. The main aspects of the program are reviewed with emphasis on the newest features of the current fifth-generation version (Mark V) and an upcoming more fully HFC-capable release (Mark VI). Current model predictions are compared to test data for a leading HFC alternative to HCFC-22 in heat pumps. Examples are shown of some user interfaces that have been recently developed for the program. To demonstrate the design capabilities of the model for R-22 alternatives, a refrigerant-side optimization was conducted to find the best balance of heat transfer versus pressure drop for HCFC R-22, HFCs R-134a and R-410A, and the natural refrigerant propane. COP was maximized while refrigerant charge and tube size were minimized. Independent design parameters were fraction of total area in the outdoor coil, tube diameter and number of circuits for each heat exchanger, and condenser subcooling. Heat exchanger design tradeoffs are discussed for a heat pump relative to air conditioners and heating-only units. A design optimized for heating-only operation is presented.

Rice, C.K.

1997-12-01T23:59:59.000Z

439

Large HVAC Codes and Standards Update 2000: American Society of Heating, Refrigerating and Air-Conditioning Engineers  

Science Conference Proceedings (OSTI)

This report documents EPRI activities in the year 2000 related to building codes and standards. The following activities are covered: attendance at the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) meetings and participation in technical committee and subcommittee meetings related to ASHRAE Standard 90.l; review of relevant U.S Department of Energy (DOE) appliance standards; review of developments of other building energy code organizations; and participation in the E...

2000-12-13T23:59:59.000Z

440

Building Energy Software Tools Directory: Tools by Country -...  

NLE Websites -- All DOE Office Websites (Extended Search)

room, cooler, freezer, refrigerated warehouse Software has been updated. Cool Room Calc cooling load, heat gains, heat loads, air-conditioned room, air conditioner, HVAC, air...

Note: This page contains sample records for the topic "air conditioners heat" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Global Potential of Energy Efficiency Standards and Labeling Programs  

E-Print Network (OSTI)

Standby Power, Oven, Water Heating and Space Heating 謬elevision Water Heating Oven Air Conditioner Fan Standbyby Power Devices Oven Water Heating Space Heating Lighting

McNeil, Michael A

2008-01-01T23:59:59.000Z

442

Probability Distribution Characteristics for Surface Air亡ea Turbulent Heat Fluxes over the Global Ocean  

Science Conference Proceedings (OSTI)

To analyze the probability density distributions of surface turbulent heat fluxes, the authors apply the two-parametric modified Fisher傍ippett (MFT) distribution to the sensible and latent turbulent heat fluxes recomputed from 6-hourly NCEP鋒CAR ...

Sergey K. Gulev; Konstantin Belyaev

2012-01-01T23:59:59.000Z

443

Development of an air-cooled, loop-type heat pipe with multiple condensers  

E-Print Network (OSTI)

Thermal management challenges are prevalent in various applications ranging from consumer electronics to high performance computing systems. Heat pipes are capillary-pumped devices that take advantage of the latent heat ...

Kariya, H. Arthur (Harumichi Arthur)

2012-01-01T23:59:59.000Z

444

Performance evaluation of a solar air-heating and nocturnal cooling system in CSU Solar House II. Final report, June 1, 1977-September 30, 1978  

DOE Green Energy (OSTI)

The solar heating system in Solar House II consists of 67.1 m/sup 2/ of double-glazed air-heating collectors with flat-black absorbers, 10.3 m/sup 3/ of pebble bed storage, air-to-water heat exchanger for preheating domestic water and one blower to circulate the air through the system. The nocturnal cooling system consists of an evaporative cooler and utilizes the pebble bed for cool storage. A schematic diagram of the system is shown.

Karaki, S.

1979-04-01T23:59:59.000Z

445

Energy Saving Potentials and Air Quality Benefits of Urban Heat IslandMitigation  

E-Print Network (OSTI)

Solar Absorptance, Attic, and Duct Insulation on Cooling and Heating Energy Use in Single-Family New Residential Buildings,

Akbari, Hashem

2005-01-01T23:59:59.000Z

446

Opportunities for Saving Energy and Improving Air Quality in Urban Heat Islands  

E-Print Network (OSTI)

Solar Absorptance, Attic, and Duct Insulation on Cooling and Heating Energy Use in Single-Family New Residential Buildings,

Akbari, Hashem

2008-01-01T23:59:59.000Z

447

Acoustical prediction methods for heating, ventilating, and air?conditioning (HVAC) systems  

Science Conference Proceedings (OSTI)

The goal of this project is to compare and contrast various aspects of acoustical prediction methods for heating

2005-01-01T23:59:59.000Z

448

Measure Guideline: Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems  

SciTech Connect

This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

Rudd, A.

2012-08-01T23:59:59.000Z

449

Buildings Energy Data Book: 5.3 Heating, Cooling, and Ventilation...  

Buildings Energy Data Book (EERE)

Lifetimes and Ages Median Equipment Type Lifetime Air Conditioners Through-the-Wall 15 Water-CooledPackage 24 (1) Roof-Top 15 Chillers Reciprocating 20 Centrifugal 25 (1)...

450

Procuring Energy-Efficient Products (Fact Sheet) (Revised), Federal Energy Management Program (FEMP)  

NLE Websites -- All DOE Office Websites (Extended Search)

Space Heating Space Heating and Cooling * Boilers p * Central Air Conditioners n * Chillers - Air-Cooled Electric p - Water-Cooled Electric p * Air Source Heat Pumps n Commercial Water Heating * Gas Water Heaters p Residential Space Heating and Cooling * Room Air Conditioners n * Central Air Conditioners n * Boilers n * Fans - Ceiling n - Ventilation n * Gas Furnaces n * Heat Pumps - Air Source n - Ground-Source n Residential Water Heating * Electric Resistance Storage p * Heat Pump n

451

Procuring Energy-Efficient Products (Fact Sheet) (Revised), Federal Energy Management Program (FEMP)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Space Heating Space Heating and Cooling * Boilers p * Central Air Conditioners n * Chillers - Air-Cooled Electric p - Water-Cooled Electric p * Air Source Heat Pumps n Commercial Water Heating * Gas Water Heaters p Residential Space Heating and Cooling * Room Air Conditioners n * Central Air Conditioners n * Boilers n * Fans - Ceiling n - Ventilation n * Gas Furnaces n * Heat Pumps - Air Source n - Ground-Source n Residential Water Heating * Electric Resistance Storage p * Heat Pump n

452

Stronger Manufacturers' Energy Efficiency Standards for Residential Air  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Stronger Manufacturers' Energy Efficiency Standards for Residential Stronger Manufacturers' Energy Efficiency Standards for Residential Air Conditioners Go Into Effect Today Stronger Manufacturers' Energy Efficiency Standards for Residential Air Conditioners Go Into Effect Today January 23, 2006 - 11:09am Addthis WASHINGTON, DC -- To increase the energy efficiency of residential air conditioners, the U.S. Department of Energy (DOE) has issued new manufacturing standards that go into effect today, January 23, 2006, for products manufactured in, or imported into, the United States. "Homeowners who choose to buy more energy-efficient air conditioning systems after today will realize significant savings in their energy bills and greatly reduce their energy use," said Secretary of Energy Samuel W. Bodman. "These new energy efficiency standards are the first of several

453

Air Conditioning Stall Phenomenon Testing, Model Development, and Simulation  

Science Conference Proceedings (OSTI)

Electric distribution systems are experiencing power quality issues of extended reduced voltage due to fault-induced delayed voltage recovery (FIDVR). FIDVR occurs in part because modern air conditioner (A/C) and heat pump compressor motors are much more susceptible to stalling during a voltage sag or dip such as a sub-transmission fault. They are more susceptible than older A/C compressor motors due to the low inertia of these newer and more energy efficient motors. There is a concern that these local reduced voltage events on the distribution system will become more frequent and prevalent and will combine over larger areas and challenge transmission system voltage and ultimately power grid reliability. The Distributed Energy Communications and Controls (DECC) Laboratory at Oak Ridge National Laboratory (ORNL) has been employed to (1) test, (2) characterize and (3) model the A/C stall phenomenon.

Irminger, Philip [ORNL; Rizy, D Tom [ORNL; Li, Huijuan [ORNL; Smith, Travis [ORNL; Rice, C Keith [ORNL; Li, Fangxing [ORNL; Adhikari, Sarina [ORNL

2012-01-01T23:59:59.000Z

454

Using Transformation and Formation Maps to Study the Role of Air亡ea Heat Fluxes in North Atlantic Eighteen Degree Water Formation  

Science Conference Proceedings (OSTI)

The Walin water mass framework quantifies the rate at which water is transformed from one temperature class to another by air穆ea heat fluxes (transformation). The divergence of the transformation rate yields the rate at which a given temperature ...

Guillaume Maze; Gael Forget; Martha Buckley; John Marshall; Ivana Cerovecki

2009-08-01T23:59:59.000Z

455

Air亡ea Heat Exchanges Characteristic of a Prominent Midlatitude Oceanic Front in the South Indian Ocean as Simulated in a High-Resolution Coupled GCM  

Science Conference Proceedings (OSTI)

An integration of a high-resolution coupled general circulation model whose ocean component is eddy permitting and thus able to reproduce a sharp gradient in sea surface temperature (SST) is analyzed to investigate air穆ea heat exchanges ...

Masami Nonaka; Hisashi Nakamura; Bunmei Taguchi; Nobumasa Komori; Akira Kuwano-Yoshida; Koutarou Takaya

2009-12-01T23:59:59.000Z

456

Heat transfer characteristics of a two-phase, air-water direct contact evaporator.  

E-Print Network (OSTI)

??The purpose of the research was to carry out an experimental and theoretical investigation of the heat transfer on a direct contact column for desalination (more)

Zanette, Luca

2013-01-01T23:59:59.000Z

457

Development of an air-cooled, loop-type heat pipe with multiple condensers.  

E-Print Network (OSTI)

??Thermal management challenges are prevalent in various applications ranging from consumer electronics to high performance computing systems. Heat pipes are capillary-pumped devices that take advantage (more)

Kariya, H. Arthur (Harumichi Arthur)

2012-01-01T23:59:59.000Z

458

The Study of Heat and Mass Transfer In The Generator For an Absorption Air Conditioning System.  

E-Print Network (OSTI)

??This thesis is aimed to study the heat and mass transfer performance of a generator for the absorption cooling system. Both aqueous lithium bromide (LiBr) (more)

Hsu, Yu-lien

2012-01-01T23:59:59.000Z

459

Cascade Reverse Osmosis Air Conditioning System: Cascade Reverse Osmosis and the Absorption Osmosis Cycle  

SciTech Connect

BEETIT Project: Battelle is developing a new air conditioning system that uses a cascade reverse osmosis (RO)-based absorption cycle. Analyses show that this new cycle can be as much as 60% more efficient than vapor compression, which is used in 90% of air conditioners. Traditional vapor-compression systems use polluting liquids for a cooling effect. Absorption cycles use benign refrigerants such as water, which is absorbed in a salt solution and pumped as liquid羊eplacing compression of vapor. The refrigerant is subsequently separated from absorbing salt using heat for re-use in the cooling cycle. Battelle is replacing thermal separation of refrigerant with a more efficient reverse osmosis process. Research has shown that the cycle is possible, but further investment will be needed to reduce the number of cascade reverse osmosis stages and therefore cost.

None

2010-09-01T23:59:59.000Z

460

Analysis of fluid flow and heat transfer in a rib grit roughened surface solar air heater using CFD  

SciTech Connect

This paper presents the study of fluid flow and heat transfer in a solar air heater by using Computational Fluid Dynamics (CFD) which reduces time and cost. Lower side of collector plate is made rough with metal ribs of circular, square and triangular cross-section, having 60 inclinations to the air flow. The grit rib elements are fixed on the surface in staggered manner to form defined grid. The system and operating parameters studied are: e/D{sub h} = 0.044, p/e = 17.5 and l/s = 1.72, for the Reynolds number range 3600-17,000. To validate CFD results, experimental investigations were carried out in the laboratory. It is found that experimental and CFD analysis results give the good agreement. The optimization of rib geometry and its angle of attack is also done. The square cross-section ribs with 58 angle of attack give maximum heat transfer. The percentage enhancement in the heat transfer for square plate over smooth surface is 30%. (author)

Karmare, S.V. [Department of Mechanical Engineering, Government College Engineering, Karad 415 124, Maharashtra (India); Shivaji University, Kolhapur, Maharashtra (India); Tikekar, A.N. [Department of Mechanical Engineering, Walchand College of Engineering, Sangli (India); Shivaji University, Kolhapur, Maharashtra (India)

2010-03-15T23:59:59.000Z