Powered by Deep Web Technologies
Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Adsorption air conditioner  

DOE Patents (OSTI)

A solar powered air conditioner using the adsorption process is constructed with its components in a nested cylindrical array for compactness and ease of operation.

Rousseau, Jean L. I. (Redondo Beach, CA)

1979-01-01T23:59:59.000Z

2

Room Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

of Superefficient Room Air Conditioners year month keywords appliance energy efficiency energy efficiency incentives Market Transformation standards url https isswprod lbl gov...

3

Central Air conditioners | Open Energy Information  

Open Energy Info (EERE)

Page Edit History Facebook icon Twitter icon Central Air conditioners Jump to: navigation, search TODO: Add description List of Central Air conditioners Incentives Retrieved...

4

air conditioner | OpenEI  

Open Energy Info (EERE)

air conditioner air conditioner Dataset Summary Description View 2010 energy efficiency data from AeroSys Inc, Coaire, Cold Point, First Operations, LG Electronics, Nordyne, and Quietside manufacturers. Data includes cooling capacity, cooling performance, heating capacity, and heating performance. Spreadsheet was created by combining the tables in pdf files that are included in the zip file. Source Energy Applicance Data - United States Federal Trade Commission, www.ftc.gov Date Released Unknown Date Updated Unknown Keywords air conditioner central air conditioner efficiency efficient energy heat pump Data application/vnd.ms-excel icon 2010_CentralAC_All.xls (xls, 82.4 KiB) application/zip icon 2010CentralAirConditioner.zip (zip, 398.2 KiB) Quality Metrics Level of Review Some Review

5

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Room Air Conditioners Room Air Conditioners Room Air Conditioners July 1, 2012 - 5:35pm Addthis A window air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/kschulze. A window air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/kschulze. What does this mean for me? Room air conditioners are less expensive and disruptive to install than central air conditioning systems. Room air conditioners can be a cost-effective alternative to central air conditioning systems. How does it work? Room air conditioners work by cooling one part of your home. Room or window air conditioners cool rooms rather than the entire home or business. If they provide cooling only where they're needed, room air conditioners are less expensive to operate than central units, even though

6

Maintaining Your Air Conditioner | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Maintaining Your Air Conditioner Maintaining Your Air Conditioner Maintaining Your Air Conditioner June 18, 2013 - 6:20pm Addthis Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. What does this mean for me? Regular maintenance keeps your air conditioner running as efficiently as possible. Maintaining your air conditioner will save you money by extending the unit's life. An air conditioner's filters, coils, and fins require regular maintenance for the unit to function effectively and efficiently throughout its years of service. Neglecting necessary maintenance ensures a steady decline in air conditioning performance while energy use steadily increases.

7

Maintaining Your Air Conditioner | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Maintaining Your Air Conditioner Maintaining Your Air Conditioner Maintaining Your Air Conditioner June 18, 2013 - 6:20pm Addthis Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. What does this mean for me? Regular maintenance keeps your air conditioner running as efficiently as possible. Maintaining your air conditioner will save you money by extending the unit's life. An air conditioner's filters, coils, and fins require regular maintenance for the unit to function effectively and efficiently throughout its years of service. Neglecting necessary maintenance ensures a steady decline in air conditioning performance while energy use steadily increases.

8

Common Air Conditioner Problems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Common Air Conditioner Problems Common Air Conditioner Problems Common Air Conditioner Problems May 30, 2012 - 6:41pm Addthis A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. What does this mean for me? You can eliminate the most common air conditioner problems before hiring an air conditioning technician. You can do some air conditioner maintenance and repair tasks yourself. One of the most common air conditioning problems is improper operation. If your air conditioner is on, be sure to close your home's windows and outside doors. For room air conditioners, isolate the room or a group of connected rooms as much as possible from the rest of your home.

9

Common Air Conditioner Problems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Common Air Conditioner Problems Common Air Conditioner Problems Common Air Conditioner Problems May 30, 2012 - 6:41pm Addthis A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. What does this mean for me? You can eliminate the most common air conditioner problems before hiring an air conditioning technician. You can do some air conditioner maintenance and repair tasks yourself. One of the most common air conditioning problems is improper operation. If your air conditioner is on, be sure to close your home's windows and outside doors. For room air conditioners, isolate the room or a group of connected rooms as much as possible from the rest of your home.

10

Tips: Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips: Air Conditioners Tips: Air Conditioners Tips: Air Conditioners June 24, 2013 - 6:31pm Addthis Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Buying a bigger room air conditioner won't necessarily make you feel more comfortable during the hot summer months. In fact, a room air conditioner that's too big for the area it is supposed to cool will perform less efficiently and less effectively than a smaller, properly sized unit. The reason: an oversized unit will cool the room(s) to the thermostat set-point before proper dehumidification occurs, making the area feel "clammy"

11

Tips: Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips: Air Conditioners Tips: Air Conditioners Tips: Air Conditioners June 24, 2013 - 6:31pm Addthis Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Buying a bigger room air conditioner won't necessarily make you feel more comfortable during the hot summer months. In fact, a room air conditioner that's too big for the area it is supposed to cool will perform less efficiently and less effectively than a smaller, properly sized unit. The reason: an oversized unit will cool the room(s) to the thermostat set-point before proper dehumidification occurs, making the area feel "clammy"

12

The Beeping Air Conditioner : EnergySmart School Inventors  

NLE Websites -- All DOE Office Websites (Extended Search)

The Beeping Air Conditioner icon. The Beeping Air Conditioner Work in Progress Sketches Team Picture Miniature Hydroelectric Power Plant icon The Plugger icon. The Light Searcher...

13

Electrolux Gibson Air Conditioner and Equator Clothes Washer...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing...

14

central air conditioner | OpenEI  

Open Energy Info (EERE)

central air conditioner central air conditioner Dataset Summary Description View 2010 energy efficiency data from AeroSys Inc, Coaire, Cold Point, First Operations, LG Electronics, Nordyne, and Quietside manufacturers. Data includes cooling capacity, cooling performance, heating capacity, and heating performance. Spreadsheet was created by combining the tables in pdf files that are included in the zip file. Source Energy Applicance Data - United States Federal Trade Commission, www.ftc.gov Date Released Unknown Date Updated Unknown Keywords air conditioner central air conditioner efficiency efficient energy heat pump Data application/vnd.ms-excel icon 2010_CentralAC_All.xls (xls, 82.4 KiB) application/zip icon 2010CentralAirConditioner.zip (zip, 398.2 KiB) Quality Metrics Level of Review Some Review

15

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

you need to mount the air conditioner at the narrow end of a long room, then look for a fan control known as "Power Thrust" or "Super Thrust" that sends the cooled air farther...

16

Ductless Mini-Split Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners August 9, 2012 - 4:05pm Addthis A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. What does this mean for me? A ductless mini-split air conditioner is easier to install than a central air conditioning system. A ductless mini-split air conditioner provides zoned air conditioning without ducting. A ductless mini-split air conditioner is relatively easy to install and does not provide an entry point for intruders as some room air conditioners do. Ductless, mini split-system air-conditioners (mini splits) have numerous

17

Ductless Mini-Split Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners August 9, 2012 - 4:05pm Addthis A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. What does this mean for me? A ductless mini-split air conditioner is easier to install than a central air conditioning system. A ductless mini-split air conditioner provides zoned air conditioning without ducting. A ductless mini-split air conditioner is relatively easy to install and does not provide an entry point for intruders as some room air conditioners do. Ductless, mini split-system air-conditioners (mini splits) have numerous

18

Building Technologies Office: Energy-Efficient Window Air Conditioner  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy-Efficient Window Energy-Efficient Window Air Conditioner Ratings Research Project to someone by E-mail Share Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Facebook Tweet about Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Twitter Bookmark Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Google Bookmark Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Delicious Rank Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Digg Find More places to share Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on

19

DOE Investigates Possible Air Conditioner Efficiency Violations |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Investigates Possible Air Conditioner Efficiency Violations Investigates Possible Air Conditioner Efficiency Violations DOE Investigates Possible Air Conditioner Efficiency Violations February 15, 2012 - 5:13pm Addthis The Department of Energy's Office of Enforcement is committed to its compliance enforcement responsibilities with regard to federal energy conservation standards and ensuring that all those subject to the requirements are treated fairly and equally. Today, the Office of Enforcement issued a series of subpoenas as part of an investigation to determine whether manufacturers of split-system air conditioners are making and distributing in the U.S. condensing units that do not meet the current 13 SEER (Seasonal Energy Efficiency Ratio) federal energy conservation standard, which has been the standard since 2006.

20

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

will result in rising sales prices. VRF Air Conditioner Themain users of VRF air conditioners are commercial usersand large-scale households, and VRF air conditioners usually

Zhou, Nan

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Stirling Air Conditioner for Compact Cooling  

Science Conference Proceedings (OSTI)

BEETIT Project: Infinia is developing a compact air conditioner that uses an unconventional high efficient Stirling cycle system (vs. conventional vapor compression systems) to produce cool air that is energy efficient and does not rely on polluting refrigerants. The Stirling cycle system is a type of air conditioning system that uses a motor with a piston to remove heat to the outside atmosphere using a gas refrigerant. To date, Stirling systems have been expensive and have not had the right kind of heat exchanger to help cool air efficiently. Infinia is using chip cooling technology from the computer industry to make improvements to the heat exchanger and improve system performance. Infinias air conditioner uses helium gas as refrigerant, an environmentally benign gas that does not react with other chemicals and does not burn. Infinias improvements to the Stirling cycle system will enable the cost-effective mass production of high-efficiency air conditioners that use no polluting refrigerants.

None

2010-09-01T23:59:59.000Z

22

Four Central Air Conditioners Determined Noncompliant With Energy...  

NLE Websites -- All DOE Office Websites (Extended Search)

Action Against AeroSys, Inc. for Failure to Certify Air Conditioners and Heat Pumps DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump...

23

Evaluation of Energy-Efficiency Standards for Room Air Conditioners...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy-Efficiency Standards for Room Air Conditioners in the US Title Evaluation of Energy-Efficiency Standards for Room Air Conditioners in the US Publication Type Journal Article...

24

Product Standards for Air Conditioners (Japan) | Open Energy Information  

Open Energy Info (EERE)

Air Conditioners (Japan) Air Conditioners (Japan) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Product Standards for Air Conditioners (Japan) Focus Area: Appliances & Equipment Topics: Policy Impacts Website: www.eccj.or.jp/top_runner/pdf/tr_air_conditioners_apr.2008.pdf Equivalent URI: cleanenergysolutions.org/content/product-standards-air-conditioners-ja Language: English Policies: "Deployment Programs,Regulations" is not in the list of possible values (Deployment Programs, Financial Incentives, Regulations) for this property. DeploymentPrograms: Industry Codes & Standards Regulations: Appliance & Equipment Standards and Required Labeling This Energy Conservation Center Japan (ECCJ) document was created as a guide in response to its newly established set of standards and labelling

25

Analysis of Efficiency Standards for Air Conditioners, Air ...  

U.S. Energy Information Administration (EIA)

Federal agencies to select ENERGY STAR and ... analyze the proposed air conditioner and heat pump standards, a new baseline ... square foot office building 0.4 to 0.8 ...

26

Improving Air Conditioner and Heat Pump Modeling  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Improving Air-Conditioner Improving Air-Conditioner and Heat Pump Modeling Building America Stakeholders Meeting Jon Winkler March 2, 2012 2 * How do you recommend the most cost-effective A/C? Simple Question 3 Solution Whole-House Simulation Tool A/C Information * SEER 13 * SEER 14 * SEER 15 * SEER 16 * SEER 17 * SEER 18 * SEER 21 Annualized Cooling Cost (Energy + Equipment) 4 Background * Power, capacity and SHR vary with: o Outdoor temperature o Entering wetbulb o Air mass flow rate o Part load ratio Power Sensible Capacity Latent Capacity * How to accurately and easily model A/C performance? 5 Background: Model Development * A/C modeling utilizes two types of input o Rated values (capacity, efficiency, etc.) o Performance curves Capacity 1 / Efficiency 6 Background: Manufacturer's Data

27

New and Underutilized Technology: Liquid Desiccant Air Conditioner |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Liquid Desiccant Air Conditioner Liquid Desiccant Air Conditioner New and Underutilized Technology: Liquid Desiccant Air Conditioner October 4, 2013 - 4:40pm Addthis The following information outlines key deployment considerations for liquid desiccant air conditioners (LDACs) within the Federal sector. Benefits Liquid desiccant air conditioners deeply dry air using natural gas, solar energy, waste heat, bio-fuel, or other fossil fuels to drive the system. By providing mostly latent cooling, the LDAC controls indoor humidity without overcooling and reheating. This unit is supplemented by an electric chiller or DX air conditioner that sensibly cools the building's recirculation air. The liquid desiccant is a concentrated salt solution that directly absorbs moisture. Application LDACs are applicable in hospital, office, prison, school, and service

28

Covered Product Category: Residential Central Air Conditioners | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Central Air Conditioners Central Air Conditioners Covered Product Category: Residential Central Air Conditioners October 7, 2013 - 10:38am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including residential central air conditioners (CACs), which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases

29

Air Conditioner Compressor Performance Model  

SciTech Connect

During the past three years, the Western Electricity Coordinating Council (WECC) Load Modeling Task Force (LMTF) has led the effort to develop the new modeling approach. As part of this effort, the Bonneville Power Administration (BPA), Southern California Edison (SCE), and Electric Power Research Institute (EPRI) Solutions tested 27 residential air-conditioning units to assess their response to delayed voltage recovery transients. After completing these tests, different modeling approaches were proposed, among them a performance modeling approach that proved to be one of the three favored for its simplicity and ability to recreate different SVR events satisfactorily. Funded by the California Energy Commission (CEC) under its load modeling project, researchers at Pacific Northwest National Laboratory (PNNL) led the follow-on task to analyze the motor testing data to derive the parameters needed to develop a performance models for the single-phase air-conditioning (SPAC) unit. To derive the performance model, PNNL researchers first used the motor voltage and frequency ramping test data to obtain the real (P) and reactive (Q) power versus voltage (V) and frequency (f) curves. Then, curve fitting was used to develop the P-V, Q-V, P-f, and Q-f relationships for motor running and stalling states. The resulting performance model ignores the dynamic response of the air-conditioning motor. Because the inertia of the air-conditioning motor is very small (H<0.05), the motor reaches from one steady state to another in a few cycles. So, the performance model is a fair representation of the motor behaviors in both running and stalling states.

Lu, Ning; Xie, YuLong; Huang, Zhenyu

2008-09-05T23:59:59.000Z

30

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network (OSTI)

ground water source), electrically operated, unitary central air conditioners and central air conditioning heat pumps

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

31

List of Room Air Conditioners Incentives | Open Energy Information  

Open Energy Info (EERE)

Conditioners Incentives Conditioners Incentives Jump to: navigation, search The following contains the list of 112 Room Air Conditioners Incentives. CSV (rows 1 - 112) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility Nonprofit Schools State Government Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Water Heaters Commercial Cooking Equipment Commercial Refrigeration Equipment Room Air Conditioners Yes Alexandria Light and Power - Residential Energy Efficiency Rebate Program (Minnesota) Utility Rebate Program Minnesota Residential Central Air conditioners

32

Rating of Mixed Split Residential Air Conditioners  

E-Print Network (OSTI)

A methodology is presented for rating the performance of mixed, split residential air conditioners. The method accounts for the impact on system performance of the indoor evaporator, expansion device and fan; three major components that are likely to be substituted for the matched components in a mixed system. The method allows calculation of capacity at 95F rating point and seasonal energy efficiency ratio, SEER, without performing laboratory test of the complete system. Limitations of the procedure, present work, and anticipated improvements are also discussed.

Domanski, P. A.

1988-01-01T23:59:59.000Z

33

Building Energy Software Tools Directory: Room Air Conditioner Cost  

NLE Websites -- All DOE Office Websites (Extended Search)

Room Air Conditioner Cost Estimator Room Air Conditioner Cost Estimator Screen capture of Room Air Conditioner Cost Estimator The cost estimator compares high-efficiency room air conditioners to standard equipment in terms of life cycle cost. It provides an alternative to complicated building simulation models, while offering more precision than simplified estimating tools that are commonly available. The cost estimator assists decision-making regarding the purchase or replacement of room air conditioning equipment, by estimating a product�s lifetime energy cost savings at various efficiency levels. Screen Shots Keywords air conditioner, life-cycle cost, energy performance, residential buildings, energy savings Validation/Testing Internal reviews at Pacific Northwest National Laboratory.

34

Inverter control systems in the residential heat pump air conditioner  

SciTech Connect

A compressor capacity control with an inverter has been considered from the viewpoint of high energy saving in a refrigerating cycle. However, the system has not been put into practical use because of high initial cost, technical problems of electronic parts, and complexity of system control. In this connection, we developed the new inverter-controlled heat-pump air conditioner by using the latest electronics and refrigeration technology. This paper discusses the trend of energy saving in air conditioners in Japan and the objectives of developing the inverter controlled air conditioner. It also discusses the following items with respect to the inverter controlled air conditioner and the effects of employing an inverter: 1. Inverter for air conditioning; 2. Refrigeration cycle; 3. Air conditioner control with inverter.

Shimma, Y.; Tateuchi, T.; Suglura, H.

1985-01-01T23:59:59.000Z

35

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump...

36

Measuring Short-term Air Conditioner Demand Reductions for  

E-Print Network (OSTI)

allow users to look up the demand reduction per device based on the daily maximum temperatureLBNL-5330E Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement-term Air Conditioner Demand Reductions for Operations and Settlement Josh Bode, Michael J. Sullivan Freeman

37

Study on Water-Cooled Solar Semiconductor Air Conditioner  

Science Conference Proceedings (OSTI)

Water-cooled solar semiconductor air conditioner was designed. Relevant calculation was made to determine the room's cooling load, which export the solar panels and battery capacity, followed by selection of CNC matcher. Development work also involves ... Keywords: solar energy, peltier effect, semiconductor air conditioner

Dong Zhi-Ming; Chang Ji-Bin; Xiang Li-Juan; Zhou Xue-Bin

2012-04-01T23:59:59.000Z

38

ENERGY STAR Qualified Room Air Conditioners | Data.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Room Air Conditioners Room Air Conditioners Consumer Data Apps Challenges Resources About Blogs Let's Talk Feedback Consumer You are here Data.gov » Communities » Consumer » Data ENERGY STAR Qualified Room Air Conditioners Dataset Summary Description Room Air Conditioners that have earned the ENERGY STAR are more efficient than standard models. ENERGY STAR is the trusted symbol for energy efficiency helping consumers save money and protect the environment through energy-efficient products and practices. More information on ENERGY STAR is available at www.energystar.gov. Tags {"Room Air Conditioners","Energy Star",products,"energy efficiency",efficient,"greenhouse gas emissions",climate,utility,utilities,household,savings,labels,partners,certification}

39

Four Central Air Conditioners Determined Noncompliant With Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Four Central Air Conditioners Determined Noncompliant With Energy Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard October 3, 2011 - 9:21am Addthis The U.S. Department of Energy's Office of Enforcement issued a Notice of Noncompliance Determination (Notice) on September 27, 2011, to AeroSys, Inc. (AeroSys) regarding four models of central (through-the-wall) air conditioners that fail to meet Federal energy efficiency requirements. DOE tests revealed that AeroSys through-the-wall air conditioner models THDC-18S, THDC-18T, THDC-24S, and THDC-24T do not meet the minimum energy efficiency requirements set forth in DOE regulations. The Notice provides that AeroSys must inform those to whom it has sold the models that they do

40

Commercial Central Air Conditioners, Purchasing Specifications for Energy-Efficient Products (Fact Sheet)  

Science Conference Proceedings (OSTI)

Energy efficiency purchasing specifications for federal procurements of commercial central air conditioners.

Not Available

2011-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing October 6, 2010 - 10:08am Addthis DOE testing in support of the ENERGY STAR program has revealed that an Electrolux Gibson air conditioner (model GAH105Q2T1) and an Equator clothes washer (model EZ 3720 CEE), both of which claimed ENERGY STAR ratings, do not meet the ENERGY STAR requirements. Specifically, the test results for the Electrolux Gibson model show that, when tested in accordance with DOE's test procedures, it consumed 6.1 percent more energy than the Energy Star requirement. Test results for the Equator model show that it exceeds Energy Star's water factor requirements by 12.3 percent.

42

Covered Product Category: Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Room Air Conditioners Room Air Conditioners Covered Product Category: Room Air Conditioners October 7, 2013 - 10:40am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including room air conditioners, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

43

Covered Product Category: Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Room Air Conditioners Room Air Conditioners Covered Product Category: Room Air Conditioners October 7, 2013 - 10:40am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including room air conditioners, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

44

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing October 6, 2010 - 10:08am Addthis DOE testing in support of the ENERGY STAR program has revealed that an Electrolux Gibson air conditioner (model GAH105Q2T1) and an Equator clothes washer (model EZ 3720 CEE), both of which claimed ENERGY STAR ratings, do not meet the ENERGY STAR requirements. Specifically, the test results for the Electrolux Gibson model show that, when tested in accordance with DOE's test procedures, it consumed 6.1 percent more energy than the Energy Star requirement. Test results for the Equator model show that it exceeds Energy Star's water factor requirements by 12.3 percent.

45

List of Central Air conditioners Incentives | Open Energy Information  

Open Energy Info (EERE)

Central Air conditioners Incentives Central Air conditioners Incentives Jump to: navigation, search The following contains the list of 1032 Central Air conditioners Incentives. CSV (rows 1-500) CSV (rows 501-1000) CSV (rows 1001-1032) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP (Central and North) - CitySmart Program (Texas) Utility Rebate Program Texas Commercial Industrial Institutional Local Government Schools Boilers Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Furnaces Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Roofs Windows Yes AEP (Central and SWEPCO) - Coolsaver A/C Tune Up (Texas) Utility Rebate Program Texas Commercial Installer/Contractor

46

Five ENERGY STAR Room Air Conditioners Fail Testing  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy's Office of Enforcement announced today that DOE testing has identified five Friedrich room air conditioners that do not meet the ENERGY STAR Programs energy...

47

Variable Speed Fan Retrofits for Computer Room Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

Variable-Speed Fan Retrofits for Computer-Room Air Conditioners Prepared for the U.S. Department of Energy Federal Energy Management Program Technology Case Study Bulletin By...

48

Improving Air-Conditioner and Heat Pump Modeling (Presentation)  

SciTech Connect

A new approach to modeling residential air conditioners and heat pumps allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted 'behind-the-scenes' without negatively impacting the reliability of energy simulations.

Winkler, J.

2012-03-01T23:59:59.000Z

49

Improving Air-Conditioner and Heat Pump Modeling (Presentation)  

SciTech Connect

A new approach to modeling residential air conditioners and heat pumps allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted 'behind-the-scenes' without negatively impacting the reliability of energy simulations.

Winkler, J.

2012-03-01T23:59:59.000Z

50

Adsorption air conditioner for electric vehicle applications. Revision 1  

DOE Green Energy (OSTI)

This paper shows an analysis of the applicability of an adsorption system for electric vehicle (EV) air conditioning. Adsorption systems are designed and optimized to provide the required cooling for four combinations of vehicle characteristics and driving cycles. The resulting adsorption systems are compared with vapor compression air conditioners that can satisfy the cooling load. The objective function is the overall system weight, which includes the cooling system weight and the weight of the battery necessary to provide energy for air conditioner operation. The system with the minimum overall weight is considered to be the best, because a lower weight results in an increased vehicle range. The results indicate that, for the conditions analyzed in this paper, vapor compression air conditioners are superior to adsorption systems not only because they are lighter, but also because they have a higher COP and are more compact.

Aceves, S.M.

1994-07-27T23:59:59.000Z

51

Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners Title Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners Publication Type Conference Proceedings Year of Publication 2000 Authors Shugars, John, Philip Coleman, Christopher T. Payne, and Laura Van Wie McGrory Conference Name Proceedings from the 2000 ACEEE Summer Study on Energy Efficiency in Buildings Volume 10 Pagination 217-226 Date Published 01/2000 Abstract The energy efficiency ofmany products has increased markedly over the past decade. A conspicuous exception to this trend is commercialpackaged rooftop air conditioners, which have experiencedlittle to no efficiency improvement since 1992 when the Energy Policy Act of 1992 imposed federal minimum standards. Packaged rooftop units have been estimated to use on the order of76 billion kWh annually in the US, at a cost ofroughly $5.6 billion. Sales of these units are growing, and the majority of units sold have energy efficiency ratios (EERs) at orjust above the current national minimum efficiency standards. In this paper we document the static efficiencies ofcommercialpackaged air conditioners, explore the reasons behindthis efficiency gap, and assess opportunities for overcoming the barriers to efficiency improvements in these products.

52

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models...

53

Thermal Energy Storage: Assessment of Ice Bear 30 Hybrid Air Conditioner  

Science Conference Proceedings (OSTI)

This report describes and documents the construction, performance, and application of a thermal energy storage system that uses ice as the storage medium. The system, Ice Bear 30 manufactured by Ice Energy Inc. located in Windsor, Colorado, is designed to provide cooling to interior spaces by circulating refrigerant within an additional evaporator coil added to a standard roof-top air conditioner. Ice storage systems exist, but what makes the Ice Bear 30 unique is its relatively small size (5 ton) for us...

2008-12-23T23:59:59.000Z

54

Rooftop Unitary Air Conditioner with Integral Dedicated Outdoor Air System  

SciTech Connect

Energy use of rooftop and other unitary air-conditioners in commercial applications accounts for about 1 quad (10{sup 15} Btu) of primary energy use annually in the U.S. [Reference 7]. The realization that this cooling equipment accounts for the majority of commercial building cooled floorspace and the majority also of commercial building energy use has spurred development of improved-efficiency equipment as well as development of stricter standards addressing efficiency levels. Another key market driver affecting design of rooftop air-conditioning equipment has been concern regarding comfort and the control of humidity. Trends for increases in outdoor air ventilation rates in certain applications, and the increasing concern about indoor air quality problems associated with humidity levels and moisture in buildings points to a need for improved dehumidification capability in air-conditioning equipment of all types. In many cases addressing this issue exacerbates energy efficiency, and vice versa. The integrated dedicated outdoor air system configuration developed in this project addresses both energy and comfort/humidity issues.

Tiax Llc

2006-02-28T23:59:59.000Z

55

APPROVED ICE STORAGE AIR CONDITIONERS Revised as of 06-18-2008  

E-Print Network (OSTI)

APPROVED ICE STORAGE AIR CONDITIONERS Revised as of 06-18-2008 The following vendors and their ice storage air conditioners models can be used in the ice storage air conditioner compliance option. Input details are listed below for the approved equipment. Manufacturer Ice Energy, Inc 9351 Eastman Park Drive

56

Laboratory Performance Testing of Residential Window Air Conditioners  

SciTech Connect

Window air conditioners are the dominant cooling product for residences, in terms of annual unit sales. They are inexpensive, portable and can be installed by the owner. For this reason, they are an attractive solution for supplemental cooling, for retrofitting air conditioning into a home which lacks ductwork, and for renters. Window air conditioners for sale in the United States are required to meet very modest minimum efficiency standards. Four window air conditioners' performance were tested in the Advanced HVAC Systems Laboratory on NREL's campus in Golden, CO. In order to separate and study the refrigerant system's performance, the unit's internal leakage pathways, the unit's fanforced ventilation, and the leakage around the unit resulting from installation in a window, a series of tests were devised that focused on each aspect of the unit's performance. These tests were designed to develop a detailed performance map to determine whole-house performance in different climates. Even though the test regimen deviated thoroughly from the industry-standard ratings test, the results permit simple calculation of an estimated rating for both capacity and efficiency that would result from a standard ratings test. Using this calculation method, it was found that the three new air conditioners' measured performance was consistent with their ratings. This method also permits calculation of equivalent SEER for the test articles. Performance datasets were developed across a broad range of indoor and outdoor operating conditions, and used them to generate performance maps.

Winkler, J.; Booten, C.; Christensen, D.; Tomerlin, J.

2013-03-01T23:59:59.000Z

57

Development of vehicle magnetic air conditioner (VMAC) technology. Final report  

SciTech Connect

The objective of Phase I was to explore the feasibility of the development of a new solid state refrigeration technology - magnetic refrigeration - in order to reduce power consumption of a vehicle air conditioner by 30%. The feasibility study was performed at Iowa State University (ISU) together with Astronautics Corporation of America Technology Center (ACATC), Madison, WI, through a subcontract with ISU.

Gschneidner, Karl A., Jr.; Pecharsky, V.K.; Jiles, David; Zimm, Carl B.

2001-08-28T23:59:59.000Z

58

Monitoring and evaluation of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached houses in Austin, Texas  

SciTech Connect

The US DOE initiated this project to evaluate the performance of an air conditioner retrofit program in Austin, Texas. The City's Austin's Resource Management Department pursued this project to quantify the retrofit effect of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached homes. If successfully implemented, this retrofit program could help defer construction of a new power plant which is a major goal of this department. The project compares data collected from 12 houses during two cooling seasons under pre-retrofit and then post-retrofit air conditioner units. The existing low-efficiency air conditioners were monitored during the 1987 cooling season, replaced during the 1987--88 heating season with new, smaller sized, high-efficiency units, and then monitored again during the 1988 cooling season. Results indicated that the air conditioner retrofits reduce the annual air conditioner electric consumption and peak electric demand by an average of 38%. When normalized to the nominal capacity of the air conditioner, average demand savings were 1.12 W/ft{sup 2} and estimated annual energy savings were 1.419 kWh/ft{sup 2}. Individual air conditioner power requirements were found to be a well defined function of outdoor temperature as expected. In the absence of detailed data, estimates of the peak demand reductions of new air conditioners can be made from the manufacturer's specifications. Air conditioner energy consumption proved to be strongly linear as a function of the outdoor temperature as expected when taken as an aggregate. No noticeable differences in the diversity factor of the air conditioner usage were found. Analysis of the retrofit effect using PRISM yields estimates of the reduction in normalized annual consumption (NAC) and annual cooling consumption of 12% and 30%. 2 refs., 11 figs., 17 tabs.

Burns, R.; Hough, R.E. (Fleming (W.S.) and Associates, Inc., Syracuse, NY (United States))

1991-10-01T23:59:59.000Z

59

Portable oven air circulator  

DOE Patents (OSTI)

A portable air circulating apparatus for use in cooking ovens which is used to create air currents in the oven which transfer heat to cooking foodstuffs to promote more rapid and more uniform cooking or baking, the apparatus including a motor, fan blade and housing of metallic materials selected from a class of heat resistant materials.

Jorgensen, Jorgen A. (Bloomington, MN); Nygren, Donald W. (Minneapolis, MN)

1983-01-01T23:59:59.000Z

60

A Preliminary Evaluation of Alternative Liquid Desiccants for a Hybrid Desiccant Air Conditioner  

E-Print Network (OSTI)

This paper presents the results of a preliminary investigation at The University of Texas at Austin of alternative liquid desiccants for use in a hybrid desiccant air-conditioning system in which a desiccant is circulated between the evaporator and the condenser of a vapor-compression air conditioner. The liquid desiccants studied were lithium chloride, lithium bromide, calcium chloride, and triethylene glycol. Each candidate desiccant was subjected to a screening process which weighed the merits of the desiccant in terms of selected characteristics. The best liquid desiccant for the anticipated application was found to be calcium chloride.

Studak, J. W.; Peterson, J. L.

1988-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

Bridging Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners John Shugars, Consultant Philip Coleman, Lawrence BerkeleyNational Laboratory ChristopherPayne, Lawrence Berkeley National Laboratory Laura Van Wie McGrory, Lawrence Berkeley National Laboratory ABSTRACT The energy efficiency ofmany products has increased markedly over the past decade. A conspicuous exception to this trend is commercial packaged rooftop air conditioners, which have experiencedlittle to no efficiency improvement since 1992 when the Energy Policy Act of 1992 imposed federal minimum standards. Packaged rooftop units have been estimated to use on the order of76 billion kWh annually in the US, at a cost ofroughly $5.6 billion. Sales of these units are growing, and the majority of units sold have energy efficiency ratios (EERs) at orjust above the current national minimum efficiency

62

Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype  

SciTech Connect

This report documents the design of a desiccant enhanced evaporative air conditioner (DEVAP AC) prototype and the testing to prove its performance. Previous numerical modeling and building energy simulations indicate a DEVAP AC can save significant energy compared to a conventional vapor compression AC (Kozubal et al. 2011). The purposes of this research were to build DEVAP prototypes, test them to validate the numerical model, and identify potential commercialization barriers.

Kozubal, E.; Woods, J.; Judkoff, R.

2012-04-01T23:59:59.000Z

63

Determining benefits and costs of improved central air conditioner efficiencies  

SciTech Connect

Economic impacts on individual consumers from possible revisions to U.S. residential-type central air conditioner energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a central air conditioner and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers due to modest increases in efficiency are significant. For an efficiency increase of 20percent over the existing minimum standard (i.e., 12 SEER), 35percent of households with central air conditioners experience significant LCC savings, with an average savings of $453, while 25percent show significant LCC losses, with an average loss of $158 compared to apre-standard LCC average of $5,170. The remainder of the population (40percent) are largely unaffected.

Rosenquist, G.; Levok, A.; Chan, P.; McMahon, J.

2001-01-12T23:59:59.000Z

64

Determining benefits and costs of improved central air conditioner efficiencies  

SciTech Connect

Economic impacts on individual consumers from possible revisions to U.S. residential-type central air conditioner energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a central air conditioner and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers due to modest increases in efficiency are significant. For an efficiency increase of 20percent over the existing minimum standard (i.e., 12 SEER), 35percent of households with central air conditioners experience significant LCC savings, with an average savings of $453, while 25percent show significant LCC losses, with an average loss of $158 compared to apre-standard LCC average of $5,170. The remainder of the population (40percent) are largely unaffected.

Rosenquist, G.; Levok, A.; Chan, P.; McMahon, J.

2001-01-12T23:59:59.000Z

65

Air Conditioner "Evolves" in Novel NIST Study  

Science Conference Proceedings (OSTI)

... A new NIST tool combining principles of engineering with those of natural evolution yielded the design for a more energy-efficient roof-top air ...

2013-09-03T23:59:59.000Z

66

The effects of galvanic corrosion on air conditioner performance  

E-Print Network (OSTI)

Corrosion of air conditioner outdoor heat exchangers (condensers) poses a significant problem for consumers living in coastal regions. This research sought to experimentally determine effects of galvanic corrosion on air conditioner condenser coils when subjected to high salt environments such as those found along the Gulf coast of the southern United States. The particular coil configuration investigated was comprised of copper tubing and aluminum fins, which form a galvanic couple in the presence of an electrolyte (salt water). Corrosion at the tube/fin junction results in a decrease of contact area through which heat is transferred. As a result, degradation of air conditioner performance occurs. An experimental plan was developed to operate two air conditioners for a period of approximately one year at a testing site in Galveston, Texas. Psychrometric evaluation of these units was conducted prior to exposure, at the midpoint of exposure, and at the conclusion of exposure. In addition, samples of copper and aluminum coils and coupons were subjected to the same coastal environment and investigated for corrosion attack. An accelerated corrosion test was also conducted to determine the effects of increased temperature, relative humidity, and salt concentrations on these samples. Air conditioner performance was measured during steady state cooling tests at outdoor conditions of 75?F (23.9?C), 82?F (27.8?C), 95?F (35.0?C), and 105?F (40.6?C) with an indoor temperature of 80?F (26.7?C) dry-bulb and 67?F (19.4?C) wet-bulb. Results of this testing showed that both units demonstrated average decreases in both cooling capacity and system EER. Sensible and latent capacity degradation for both package units showed decreases of approximately 4.6% and 20.9% respectively. System EER dropped over the course of the field investigation by 11.5% for one of the units and 8.3% for the other. An average corrosion rate for sample coupons subjected to the Galveston environment was calculated to be 0.13 MPY. Microscopic evaluation of aluminum from these galvanic couples after approximately one year of exposure showed an average pit depth approximately 19% of the aluminum thickness at the material interface. In comparison, aluminum fin collars at the material interface had an average pit about 22% of the thickness. Accelerated corrosion testing revealed some pitting, but not to the extent exhibited by field samples. A detailed description of the experimental setup, procedure, and results are provided.

Grisham, Phillip Ryan

2001-01-01T23:59:59.000Z

67

DOE Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Takes Action to Stop the Sales of Air-Con Air Conditioner Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown to Violate Federal Energy Efficiency Appliance Standards DOE Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown to Violate Federal Energy Efficiency Appliance Standards September 23, 2010 - 12:00am Addthis Washington, DC - The Department of Energy announced today that it has taken action against Air-Con, International, requiring the company to stop selling certain air conditioning systems in the U.S. that have been shown to violate minimum energy efficiency appliance standards. DOE is proposing a civil penalty of more than $230,000 for importing and distributing these inefficient cooling products. This action and the proposed penalties are part of the Department's continued commitment to act aggressively to remove

68

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy Efficiency Standard YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy Efficiency Standard October 11, 2012 - 4:10pm Addthis The U.S. Department of Energy's Office of Enforcement issued a Notice of Noncompliance Determination (Notice) on October 11, 2012, to YMGI Group, LLC (YMGI) regarding through-the-wall split system central air conditioner basic model TTWC-18K-31B. DOE enforcement testing revealed that this model operates at a Seasonal Energy Efficiency Rating (SEER) of 8.3. The current federal standard requires that through-the-wall split system central air conditioners operate at a SEER of 12 or greater. Addthis Related Articles Four Central Air Conditioners Determined Noncompliant With Energy

69

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy Efficiency Standard YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy Efficiency Standard October 11, 2012 - 4:10pm Addthis The U.S. Department of Energy's Office of Enforcement issued a Notice of Noncompliance Determination (Notice) on October 11, 2012, to YMGI Group, LLC (YMGI) regarding through-the-wall split system central air conditioner basic model TTWC-18K-31B. DOE enforcement testing revealed that this model operates at a Seasonal Energy Efficiency Rating (SEER) of 8.3. The current federal standard requires that through-the-wall split system central air conditioners operate at a SEER of 12 or greater. Addthis Related Articles Four Central Air Conditioners Determined Noncompliant With Energy

70

Conservation for window air conditioners: a guide for homeowners and weatherization crews  

SciTech Connect

Recommendations are made on the maintenance, operation, and shading of existing window air conditioners for the purpose of helping home owners conserve energy. (LCL)

Riley, J.T.; Haumberger, H. Jr.; Riley, K.L.

1978-01-01T23:59:59.000Z

71

Measured Impacts of Air Conditioner Condenser Shading  

E-Print Network (OSTI)

A study has been conducted by the Florida Solar Energy Center (FSEC) to examine if space cooling energy savings can be achieved from shading of residential air conditioning (AC) condenser units. The investigation consisted of before-and-after experiments conducted on three homes over a two year period. A recent EPA study recommends shading of exterior AC condensers, using landscaping or other means, as a method to reduce space cooling energy use (Akbari et al., 1992).

Parker, D. S.; Barkaszi, S. F.; Sonne, J. K.

1996-01-01T23:59:59.000Z

72

De-icing thermostat for air conditioners  

SciTech Connect

This patent describes an electronic thermostat adapted to be connected to an air-cooling apparatus to control the operative state of the apparatus. The thermostat includes a means for generating a digital electrical signal representative of a desired temperature setpoint and means for generating a digital electrical signal representative of the ambient temperature at the thermostat. The improvement described here comprises: means for generating control signals for the aircooling apparatus in order to inhibit the accumulation of ice on the cooling element of the air-cooling apparatus when the ambient temperature is above the temperature setpoint; means, responsive to the control signals, for deenergizing the compressor in the air-cooling apparatus for a first preselected period of time whenever the compressor is determined to have run continuously for a second preselected period of time; and means for adaptively adjusting the length of at least one of the first or second preselected periods of time as a function of the change in the rate of change of the ambient temperature.

Levine, M.R.

1986-12-09T23:59:59.000Z

73

Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications: Preprint  

DOE Green Energy (OSTI)

A novel liquid-desiccant air conditioner that dries and cools building supply air will transform the use of direct-contact liquid-desiccant systems in HVAC applications, improving comfort, air quality, and providing energy-efficient humidity control.

Lowenstein, A.; Slayzak, S.; Kozubal, E.

2006-07-01T23:59:59.000Z

74

The Impact of Energy Recovery on Window Air-conditioner Efficiency  

E-Print Network (OSTI)

An experimental energy recovering air-conditioner can produce fresh air exchange heat with exhaust air in the heat exchanger, which has no additional moving parts. The EER of the experimental air-conditioner (EAC) is increased by 17.4~37.3 percent over that of an ordinary window type air-conditioner (OAC), which is very significant for energy efficiency. On the other hand, the fresh air proportion of the EAC is increased by ~20 percent over that of the OAC, and the indoor noise of the EAC is decreased by ~3.8 dB. Therefore, indoor environment quality can be greatly improved with the EAC.

Luo, Q.; Tang, C.; Liao, K.

2006-01-01T23:59:59.000Z

75

Development of solar driven absorption air conditioners and heat pumps  

DOE Green Energy (OSTI)

The objective of this project is the development of absorption refrigeration systems for solar active heating and cooling applications. The approaches being investigated are those using air-cooled condenser-absorbers and those leading to coefficient of performances (COP) that increase continuously with heat source temperature. This is primarily an experimental project, with the emphasis on designing, fabricating and testing absorption chillers in operating regimes that are particularly suited for solar energy applications. The first phase of this project has been concluded and has experimentally demonstrated that the conventional single-effect ammonia-water absorption cycle can be used (with minor modifications) for solar cooling. The second phase of this project explores the commercial potential of the single-effect (SE) NH/sub 3//H/sub 2/O absorption air conditioner. (WHK)

Dao, K.; Wahlig, M.; Wali, E.; Rasson, J.; Molishever, E.

1980-03-01T23:59:59.000Z

76

Variable Speed Fan Retrofits for Computer Room Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Variable-Speed Fan Variable-Speed Fan Retrofits for Computer-Room Air Conditioners Prepared for the U.S. Department of Energy Federal Energy Management Program Technology Case Study Bulletin By Lawrence Berkeley National Laboratory Steve Greenberg September 2013 2 Contacts Steve Greenberg Lawrence Berkeley National Laboratory One Cyclotron Road, 90R3111 Berkeley, California 94720 (510) 486-6971 segreenberg@lbl.gov For more information on FEMP, please contact: Will Lintner, P.E., CEM Federal Energy Management Program U.S. Department of Energy 1000 Independence Ave. S.W. Washington, D. C. 20585-0121 (202) 586-3120 william.lintner@ee.doe.gov 3 Acknowledgements EPRI: Dennis Symanski, Brian Fortenbery Synapsense: Garret Smith, Patricia Nealon Vigilent: Corinne Vita

77

Laboratory Performance Testing of Residential Window Mounted Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Laboratory Performance Testing of Residential Window Mounted Air Conditioners Jon Winkler Chuck Booten Dane Christensen Jeff Tomerlin April 29, 2012 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Why should we care? * Window AC unit sales dominate US market o 7.5 million units sold in 2011 - 36% more than ducted systems - Approx. 30% of installed capacity o Inexpensive relative to central units o Easy installation o Attractive for retrofits * Need accurate models in whole-building tools o Costs/savings relative to other solutions can be quantified o Spot cooling can reduce energy use, but when, where and by

78

Influence of Air Conditioner Operation on Electricity Use and Peak Demand  

E-Print Network (OSTI)

Electricity demand due to occupant controlled room air conditioners in a large mater-metered apartment building is analyzed. Hourly data on the electric demand of the building and of individual air conditioners are used in analyses of annual and time-of-day peaks. Effects of occupant schedules and behavior are examined. We conclude that room air conditioners cause a sharp annual peak demand because occupants have strongly varying thresholds with respect to toleration of high indoor temperatures. However, time-or-day peaking is smoothed by air conditioning in this building due to significant off-peak operation of air conditioners by some occupants. If occupants were billed directly for electricity, off-peak use would probably diminish making the peaks more pronounced and exacerbating the utility company's load management problems. Future studies of this type in individually metered apartment buildings are recommended.

McGarity, A. E.; Feuermann, D.; Kempton, W.; Norford, L. K.

1987-01-01T23:59:59.000Z

79

Cromer Cycle Air Conditioner: A Unique Air-Conditioner Desiccant Cycle to Enhance Dehumidification and Save Energy  

E-Print Network (OSTI)

The Cromer cycle uses a desiccant to move moisture from the saturated air leaving an air conditioning (AC) cooling coil to the air returning to the AC unit from the conditioned space. This has the thermodynamic effect of reducing the overall energy consumption of the AC unit and also has the side benefit of dramatically increasing the moisture removal capacity of the AC coil. Simulations, engineering analysis and laboratory tests have confirmed the technical feasibility of the thermodynamics of the cycle. This work reports on a test at ARI conditions (95 deg. F outside, 80 deg F, 51% RH inside). The test unit (10 year old, 5 ton Bryant Air Conditioner) without the Cromer cycle, averaged an EER of 7.93 at a latent ratio of 26.2 % (SHR = 0.738). With the Cromer cycle added, the same unit averaged a total cooling EER of 11.82 with a water removal latent ratio of 53.4% (SHR= 0.466). The measured 16.4% reduction in energy use and 47.9 improvement in EER is significant for the tests at the 95% confidence level. This technology represents a major improvement in energy performance for the control of humidity conditions.

Cromer, C. J.

2000-01-01T23:59:59.000Z

80

Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations  

SciTech Connect

This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost effective equipment upgrade opportunities and efficiency improvements in residential buildings.

Cutler, D.; Winkler, J.; Kruis, N.; Christensen, C.; Brendemuehl, M.

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

An Evaluation of Steady-State Dehumidification Characteristics of Residential Central Air Conditioners, Final Report  

E-Print Network (OSTI)

This report is the first of two reports on the project "Determination of the Transient Response Characteristics of High Efficiency Commercial Air Conditioners" funded by Houston Lighting and Power Company. The purpose of this report is to present the results from an investigation of the possible relationship between residential central air conditioner efficiency and dehumidification performance. The method used was that of a survey of air conditioners currently manufactured and on the market as of late 1986. Chapter 2 outlines the basic terminology used in evaluating the dehumidification performance of central air conditioners. Chapter 3 provides background to the survey data. Chapter 4 presents results from the survey. Conclusions and recommendations are presented in Chapter 5.

O'Neal, D. L.; Chan, N.; Somasundaram, S.; Katipamula, S.

1987-01-01T23:59:59.000Z

82

Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates  

E-Print Network (OSTI)

An experimental study was conducted to quantify the effect of return air leakage from hot/humid attic spaces on the performance of a residential air conditioner. Tests were conducted in psychrometric facilities where temperatures and humidities could be controlled closely. Return air leakage from hot attic spaces was simulated by assuming adiabatic mixing of the indoor air at normal conditions with the attic air at high temperatures. Effective capacity and Energy Efficiency Ratio both decreased with increased return air leakage. However, power consumption was relatively constant for all variables except outdoor temperature, which meant that for the same power consumption, the unit delivered much lower performance when there was return air leakage. The increase in sensible heat ratio (SHR) with increasing leakage showed one of the most detrimental effects of return air leakage on performance.

O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

1996-01-01T23:59:59.000Z

83

Building America Top Innovations 2013 Profile … High-Efficiency Window Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

inexpensive, portable, and can be installed by inexpensive, portable, and can be installed by home occupants, making them a good solution for supplemental cooling, for installing air conditioning in homes that lack ductwork, and for renters. As a result, 7.5 million window air conditioners are purchased each year in the United States-more than all other home cooling equipment combined. However, a window air conditioner is required to meet only modest minimum efficiency standards, and its typical installation in a window causes air leakage, which significantly reduces the equipment's performance. To measure the impact these products have on home energy use, researchers at the National Renewable Energy Laboratory (NREL) studied the performance of one 10-year-old and three new window air conditioners in a range of

84

Building America Top Innovations 2013 Profile … High-Efficiency Window Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

an inexpensive, portable form of spot cooling, an inexpensive, portable form of spot cooling, making them a good solution for supplemental cooling, for air conditioning in homes that lack ductwork, and for renters. As a result, 7.5 million window air conditioners are purchased each year in the United States-more than all other home cooling equipment combined. However, window air conditioners have low minimum efficiency standards, and their installation typically results in air leakage, which significantly reduces the equipment's performance. To measure the impact these products have on home energy use, researchers at the National Renewable Energy Laboratory (NREL) studied the performance of one 10-year-old and three new window air conditioners in a range of climates and conditions at NREL's Advanced Heating, Ventilation, and

85

DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Requires Manufacturers to Halt Sales of Heat Pumps and Air Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards June 3, 2010 - 12:00am Addthis Washington, DC - Today, the Department of Energy announced that three manufacturers -- Aspen Manufacturing, Inc., Summit Manufacturing, and Advanced Distributor Products -- must stop distributing 61 heat pump models and 1 air conditioner model that DOE has determined do not comply with federal energy conservation standards. The manufacturers also must notify all of their customers that have been sold noncompliant units. The Department determined that these models were noncompliant based on certification information submitted to DOE for these manufacturers.

86

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Orders AeroSys to Halt Distribution of Inefficient Air Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models March 30, 2010 - 10:05am Addthis Today, the Department of Energy announced that it is requiring AeroSys, Inc. to stop distributing two product models - one air conditioner and one heat pump - that DOE testing found to consume more energy than allowed under federal efficiency standards. This is the latest step in the Department's investigation into whether AeroSys has been selling products in the U.S. that violate minimum appliance efficiency standards. This is the first time that the Department of Energy has told a company or manufacturer that it must halt the distribution of products that fail to

87

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and  

NLE Websites -- All DOE Office Websites (Extended Search)

Orders AeroSys to Halt Distribution of Inefficient Air Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models March 30, 2010 - 10:05am Addthis Today, the Department of Energy announced that it is requiring AeroSys, Inc. to stop distributing two product models - one air conditioner and one heat pump - that DOE testing found to consume more energy than allowed under federal efficiency standards. This is the latest step in the Department's investigation into whether AeroSys has been selling products in the U.S. that violate minimum appliance efficiency standards. This is the first time that the Department of Energy has told a company or manufacturer that it must halt the distribution of products that fail to

88

DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Manufacturers to Halt Sales of Heat Pumps and Air Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards June 3, 2010 - 2:17pm Addthis Today, the Department of Energy announced that three manufacturers -- Aspen Manufacturing, Inc., Summit Manufacturing, and Advanced Distributor Products -- must stop distributing 61 heat pump models and 1 air conditioner model that DOE has determined do not comply with federal energy conservation standards. The manufacturers also must notify all of their customers that have been sold noncompliant units. The Department determined that these models were noncompliant based on certification information submitted to DOE for these manufacturers.

89

DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Requires Manufacturers to Halt Sales of Heat Pumps and Air Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards June 3, 2010 - 2:17pm Addthis Today, the Department of Energy announced that three manufacturers -- Aspen Manufacturing, Inc., Summit Manufacturing, and Advanced Distributor Products -- must stop distributing 61 heat pump models and 1 air conditioner model that DOE has determined do not comply with federal energy conservation standards. The manufacturers also must notify all of their customers that have been sold noncompliant units. The Department determined that these models were noncompliant based on certification information submitted to DOE for these manufacturers.

90

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Orders AeroSys to Halt Distribution of Inefficient Air Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards March 30, 2010 - 12:00am Addthis WASHINGTON, DC - Today, the Department of Energy announced that it is requiring AeroSys, Inc. to stop distributing two product models - one air conditioner and one heat pump - that DOE testing found to consume more energy than allowed under federal efficiency standards. This is the latest step in the Department's investigation into whether AeroSys has been selling products in the U.S. that violate minimum appliance efficiency standards. This is the first time that the Department of Energy has told a

91

Analysis and optimization of an adsorption air conditioner for electric vehicle applications  

SciTech Connect

This paper shows an analysis of the applicability of an adsorption system for electric vehicle (EV) air conditioning. Adsorption systems are designed and optimized to provide the required cooling for four combinations of vehicle characteristics and driving cycles. The resulting adsorption systems are compared with vapor compression air conditioners that can satisfy the cooling load. The objective function is the overall system weight, which includes the cooling system weight and the weight of the battery necessary to provide energy for air conditioner operation. The system with the minimum overall weight is considered to be the best. The results show the optimum values of all the variables, as well as temperatures and amounts adsorbed, for the adsorption and desorption processes. The results indicate that, for the conditions analyzed in this paper, vapor compression air conditioners are superior to adsorption systems, not only because they are lighter, but also because they have a higher COP and are more compact.

Aceves, S.M.

1994-07-27T23:59:59.000Z

92

The Effect of Reduced Evaporator Air Flow on the Performance of a Residential Central Air Conditioner  

E-Print Network (OSTI)

This paper discusses the measured degradation in performance of a residential air conditioning system operating under reduced evaporator air flow. Experiments were conducted using a R-22 three-ton split-type cooling system with a short-tube orifice expansion device. Results are presented here for a series of tests in which the evaporator air flow was reduced from 25 to 90% below what is normally recommended for this air conditioner. At present, very little information is available which quantifies the performance of a residential cooling system operating under degraded conditions such as reduced evaporator air flow. Degraded performance measurements can provide information which could help electric utilities evaluate the potential impact of system-wide maintenance programs.

Palani, M.; O'Neal, D.; Haberl, J.

1992-05-01T23:59:59.000Z

93

Swozzle based burner tube premixer including inlet air conditioner for low emissions combustion  

DOE Patents (OSTI)

A burner for use in a combustion system of a heavy-duty industrial gas turbine includes a fuel/air premixer having an air inlet, a fuel inlet, and an annular mixing passage. The fuel/air premixer mixes fuel and air into a uniform mixture for injection into a combustor reaction zone. The burner also includes an inlet flow conditioner disposed at the air inlet of the fuel/air premixer for controlling a radial and circumferential distribution of incoming air. The pattern of perforations in the inlet flow conditioner is designed such that a uniform air flow distribution is produced at the swirler inlet annulus in both the radial and circumference directions. The premixer includes a swozzle assembly having a series of preferably air foil shaped turning vanes that impart swirl to the airflow entering via the inlet flow conditioner. Each air foil contains internal fuel flow passages that introduce natural gas fuel into the air stream via fuel metering holes that pass through the walls of the air foil shaped turning vanes. By injecting fuel in this manner, an aerodynamically clean flow field is maintained throughout the premixer. By injecting fuel via two separate passages, the fuel/air mixture strength distribution can be controlled in the radial direction to obtain optimum radial concentration profiles for control of emissions, lean blow outs, and combustion driven dynamic pressure activity as machine and combustor load are varied.

Tuthill, Richard Sterling (Bolton, CT); Bechtel, II, William Theodore (Scotia, NY); Benoit, Jeffrey Arthur (Scotia, NY); Black, Stephen Hugh (Duanesburg, NY); Bland, Robert James (Clifton Park, NY); DeLeonardo, Guy Wayne (Scotia, NY); Meyer, Stefan Martin (Troy, NY); Taura, Joseph Charles (Clifton Park, NY); Battaglioli, John Luigi (Glenville, NY)

2002-01-01T23:59:59.000Z

94

NREL: Vehicle Ancillary Loads Reduction - Air Conditioner Reduction Project  

NLE Websites -- All DOE Office Websites (Extended Search)

Conditioner Reduction Project to Reduce Vehicle Fuel Use by 30% Conditioner Reduction Project to Reduce Vehicle Fuel Use by 30% United States map depicting number of millions of gallons of cooling and dehumidification by state: Alabama 167, Alaska 1, Arizona 43, Arkansas 86, California 730, Colorado 76, Connecticut 61, Delaware 19, Florida 753, Georgia 251, Hawaii 68, Idaho 26, Illinois 242, Indiana 142, Iowa 68, Kansas 75, Kentucky 95, Louisiana 176, Maine 21, Maryland 118, Massachusetts 86, Michigan 186, Minnesota 86, Mississippi 85, Missouri 144, Montana 12, Nebraska 40, Nevada 61, New Hampshire 90, New Jersey 167, New Mexico 52, New York 273, North Carolina 187, North Dakota 12, Ohio 229, Oklahoma 109, Oregon 66, Pennsylvania 238, Rhode Island 15, South Carolina 127, South Dakota 17, Tennessee 179, Texas 735, Utah 43, Vermont 9, Virginia 187, Washington 64, West Virginia 37, Wisconsin 167, and Wyoming 7

95

Measuring Short-term Air Conditioner Demand Reductions for Operations and  

NLE Websites -- All DOE Office Websites (Extended Search)

Measuring Short-term Air Conditioner Demand Reductions for Operations and Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement Title Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement Publication Type Report LBNL Report Number LBNL-5330E Year of Publication 2012 Authors Bode, Josh, Michael J. Sullivan, and Joseph H. Eto Pagination 120 Date Published 01/2012 Publisher LBNL City Berkeley Keywords consortium for electric reliability technology solutions (certs), electricity markets and policy group, energy analysis and environmental impacts department Abstract Several recent demonstrations and pilots have shown that air conditioner (AC) electric loads can be controlled during the summer cooling season to provide ancillary services and improve the stability and reliability of the electricity grid. A key issue for integration of air conditioner load control into grid operations is how to accurately measure shorter-term (e.g., ten's of minutes to a couple of hours) demand reductions from AC load curtailments for operations and settlement. This report presents a framework for assessing the accuracy of shorter-term AC load control demand reduction measurements. It also compares the accuracy of various alternatives for measuring AC reductions - including methods that rely on regression analysis, load matching and control groups - using feeder data, household data and AC end-use data. A practical approach is recommended for settlement that relies on set of tables, updated annually, with pre-calculated load reduction estimates. The tables allow users to look up the demand reduction per device based on the daily maximum temperature, geographic region and hour of day and simplify the settlement process.

96

Performance of an air-cooled ammonia-water absorption air conditioner at low generator temperatures  

DOE Green Energy (OSTI)

An ammonia--water absorption air conditioning system has been tested to investigate the stability of operation near the cut-off conditions. Circulation ratios were from 8 to 30. Relations for the estimation of the coefficient of performance and for the prediction of operating temperatures were derived and verified experimentally. Possible operating conditions for an air-cooled ammonia--water air conditioning system were concluded.

Dao, K.; Simmons, M.; Wolgast, R.; Wahlig, M.

1976-08-01T23:59:59.000Z

97

Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Save Money and Stay Cool with an Efficient, Well-Maintained Air Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner June 29, 2010 - 7:30am Addthis Eric Barendsen Energy Technology Program Specialist, Office of Energy Efficiency and Renewable Energy OK. It's officially summer here in Washington, D.C. I'm seeking the coolest, shadiest places possible as I get ready for the hottest few months of the year. It's already been a hot June in much of the country, and it may end up being one of the hottest Junes on record in DC. Naturally, I'm starting to think about how I'm going to stay cool this summer, while trying to minimize my energy use. Drew provided some excellent tips on summertime energy savings in his blog post two weeks ago,

98

Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Save Money and Stay Cool with an Efficient, Well-Maintained Air Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner June 29, 2010 - 7:30am Addthis Eric Barendsen Energy Technology Program Specialist, Office of Energy Efficiency and Renewable Energy OK. It's officially summer here in Washington, D.C. I'm seeking the coolest, shadiest places possible as I get ready for the hottest few months of the year. It's already been a hot June in much of the country, and it may end up being one of the hottest Junes on record in DC. Naturally, I'm starting to think about how I'm going to stay cool this summer, while trying to minimize my energy use. Drew provided some excellent tips on summertime energy savings in his blog post two weeks ago,

99

The Impact of Residential Air Conditioner Charging and Sizing on Peak Electrical Demand  

E-Print Network (OSTI)

Electric utilities have had a number of air conditioner rebate and maintenance programs for many years. The purpose of these programs was to improve the efficiency of the stock of air conditioning equipment and provide better demand-side management. This paper examines the effect of refrigerant charging (proper servicing of the equipment), system sizing, and efficiency on the steady-state, coincident peak utility demand of a residential central air conditioning system. The study is based on the results of laboratory tests of a three-ton, capillary tube expansion, split-system air conditioner, system capacity and efficiency data available from manufacturer's literature, and assumptions about relative sizing of the equipment to cooling load on a residence. A qualitative discussion is provided concerning the possible impacts of transient operation and total energy use on utility program decisions. The analysis indicates that proper sizing of the unit is the largest factor affecting energy demand of the three factors (sizing, charging, and efficiency) studied in this paper. For typical oversizing of units to cooling loads in houses, both overcharging and undercharging showed significant negative impact on peak demand. The impacts of SEER changes in utility peak demand were found to be virtually independent of oversizing. For properly sized units, there was a small peak benefit to higher efficiency air conditioners.

Neal, L.; O'Neal, D. L.

1992-05-01T23:59:59.000Z

100

Issue and Improvement Measure of Multi-split Air Conditioner  

Science Conference Proceedings (OSTI)

Existing problems of traditional air source variable refrigerant flow (VRF) air-conditioning system are analyzed. The disadvantages of traditional VRF air-conditioning system are described in detail: 1) its properties are seriously affected by outdoor ... Keywords: energy saving, simulation, variable refrigerant flow air conditioning, water loop

Sun Tingting; Ni Long; Yao Yang; Ma Zuiliang; Yi Lingli

2011-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

LBNL-54244 Life-cycle Cost and Payback Period Analysis for Commercial Unitary Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

44 44 Life-cycle Cost and Payback Period Analysis for Commercial Unitary Air Conditioners Greg Rosenquist, Katie Coughlin, Larry Dale, James McMahon, Steve Meyers Energy Analysis Department Environmental Energy Technologies Division Ernest Orlando Lawrence Berkeley National Laboratory University of California Berkeley, CA 94720 March 2004 This work was supported by the Office of Building Technologies of the U.S. Department of Energy, under Contract No. DE-AC03-76SF00098. ii iii ABSTRACT This report describes an analysis of the economic impacts of possible energy efficiency standards for commercial unitary air conditioners and heat pumps on individual customers in terms of two metrics: life-cycle cost (LCC) and payback period (PBP). For each of the two equipment classes considered, the 11.5 EER provides the largest mean LCC savings. The results

102

Techno-Economic Analysis of Indian Draft Standard Levels for RoomAir Conditioners  

SciTech Connect

The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency. In support of BEE's refrigerator program, Lawrence Berkeley National Laboratory (LBNL) produced an analysis of national impacts of standards in collaboration with the Collaborative Labeling and Standards Program (CLASP). That analysis drew on LBNL's experience with standards programs in the United States, as well as many other countries. Subsequently, as part of the process for setting optimal levels for air conditioner regulations, CLASP commissioned LBNL to provide support to BEE in the form of a techno-economic evaluation of air conditioner efficiency technologies. This report describes the methodology and results of this techno-economic evaluation. The analysis consists of three components: (1) Cost effectiveness to consumers of efficiency technologies relative to current baseline. (2) Impacts on the current market from efficiency regulations. (3) National energy and financial impacts. The analysis relied on detailed and up-to-date technical data made available by BEE and industry representatives. Technical parameters were used in conjunction with knowledge about air conditioner use patterns in the residential and commercial sectors, and prevailing marginal electricity prices, in order to give an estimate of per-unit financial impacts. In addition, the overall impact of the program was evaluated by combining unit savings with market forecasts in order to yield national impacts. LBNL presented preliminary results of these analyses in May 2006, at a meeting of BEEs Technical Committee for Air Conditioners. This meeting was attended by a wide array of stakeholder, including industry representatives, engineers and consumer advocates. Comments made by stakeholders at this meeting are incorporated into the final analysis presented in this report. The current analysis begins with the Rating Plan drafted by BEE in 2006, along with an evaluation of the market baseline according to test data submitted by manufacturers. MEPS, label rating levels, and baseline efficiencies are presented in Section 2. First, we compare Indian MEPS with current standards in other countries, and assess their relative stringency. Baseline efficiencies are then used to estimate the fraction of models likely to remain on the market at each phase of the program, and the impact on market-weighted efficiency levels. Section 3 deals with cost-effectiveness of higher efficiency design options. The cost-benefit analysis is grounded in technical parameters provided by industry representatives in India. This data allows for an assessment of financial costs and benefits to consumers as a result of the standards and labeling program. A Life-Cycle Cost (LCC) calculation is used to evaluate the impacts of the program at the unit level, thus providing some insight into the appropriateness of the levels chosen, and additional opportunities for further ratcheting. In addition to LCC, we also calculate payback periods, cost of conserved energy (CCE), and return on investment (ROI). Finally, Section 4 covers national impacts. This is an extension of unit level estimates in the two previous sections. Extrapolation to the national level depends on a forecast of air conditioner purchases (shipments), which we describe here. Following the cost-benefit analysis, we construct several efficiency scenarios including the BEE plan, but also considering further potential for efficiency improvement. These are combined with shipments through a stock accounting model in order to forecast air conditioner energy consumption

McNeil, Michael A.; Iyer, Maithili

2007-03-01T23:59:59.000Z

103

13 SEER Standard for Central Air Conditioners and Heat Pumps (released in AEO2005)  

Reports and Publications (EIA)

In January 2004, after years of litigation in a case that pitted environmental groups and Attorneys General from 10 States against the U.S. Secretary of Energy, the U.S. Court of Appeals for the Second Circuit reestablished the central air conditioner and heat pump standard originally set in January 2001 [3]. The Courts ruling, which struck down a May 2002 rollback of the 2001 standard to a 12 SEER, mandates that all new central air conditioners and heat pumps meet a 13 SEER standard by January 2006, requiring a 30-percent increase in efficiency relative to current law. The AEO2005 reference case incorporates the 13 SEER standard as mandated by the Courts ruling.

Information Center

2005-04-01T23:59:59.000Z

104

Flicker Reduction Technology for Electric Heat Pumps and Central Air Conditioners  

Science Conference Proceedings (OSTI)

Electric heat pumps and air conditioners move thermal energy into and/or out of conditioned spaces. During startup, the compressor motor temporarily draws high current (inrush) from the power distribution system to accelerate the compressor from standstill to its nominal operating speed. The inrush current causes a voltage drop in the power distribution system between the compressor motor and the utility service transformer. Although very brief in durationjust fractions of a secondthe voltage drop can ca...

2011-12-28T23:59:59.000Z

105

Estimating Air Conditioner Loads Using Available Billing and Weather Data: An Exploratory Analysis  

Science Conference Proceedings (OSTI)

In limited testing, an innovative statistical technique for estimating the effects of residential air conditioners on system loads under various weather conditions produced encouraging results. The simple technique, which uses standard utility billing records and readily available weather data, could offer an inexpensive alternative to household monitoring. This report is available only to funders of Program 101A or 101.001. Funders may download this report at http://my.primen.com/Applications/DE/Commun...

1985-10-25T23:59:59.000Z

106

Determination of the Transient Dehumidification Characteristics of High Efficiency Central Air Conditioners  

E-Print Network (OSTI)

A series of tests were performed to assesses the dehumidifying performance of residential central air conditioners (CACs). The performance studies were based on factors such as: (i) dynamic performance (ii) the ASHRAE comfort zone, (iii) control strategy and (iv) published performance characteristic of the units. The units were evaluated on their ability to maintain conditions in the ASHRAE comfort zone in a typical residence and typical summer days in Houston, Texas.

Katipamula, S.; O'Neal, D. L.; Somasundaram, S.

1987-01-01T23:59:59.000Z

107

RESIDENTIAL AIR CONDITIONER FINNED-TUBE CONDENSER HEAT EXCHANGER OPTIMIZATION  

E-Print Network (OSTI)

With the upcoming ban on the production of R-22 in 2010, residential air-conditioning equipment will need to be redesigned with a more environmentally benign working fluid. R-410a is a strong candidate for replacing R-22. A model of an air-conditioning system with a focus on the finned-tube condenser design details using R-410a as the working fluid is developed. An optimization algorithm is implemented to find the optimal condenser design with various constraints for an efficiency figure of merit. The software developed is appropriate for engineering design use in the air-conditioning industry.

Susan W. Stewart; Kristinn A. Aspelund; Monifa F. Wright; Emma M. Sadler; Sam V. Shelton, Ph.D.

2002-01-01T23:59:59.000Z

108

Energy Consumption Estimation for Room Air-conditioners Using Room Temperature Simulation with One-Minute Intervals  

E-Print Network (OSTI)

For the purpose of developing optimized control algorithm for room air-conditioners to ensure their energy efficiency, a short time interval (i.e., one minute) simulation of building thermal performance is necessary because the sampling time interval for room air-conditioner control is one minute in general. This paper studies the short-time interval room air temperature simulation method using the response factor method. Using the simulated room air temperature, an air-conditioner's running time can be known so that its energy consumption can be estimated accurately. In order to verify the simulation accuracy, an actual room equipped with a gas-engine heat pump (GHP) air-conditioning system is studied by both simulation and measurement. The cooling amount produced by the GHP is calculated using measured refrigerant pressure and temperature at condenser and evaporator respectively. The Root Mean Square Error (RMSE) between measured cooling amount and simulated cooling load is 18.9 percent of the average measured value. The profile of simulated room air temperature in both air-conditioned daytime and nighttime without air-conditioning can match the measured room air temperature. With respect to the estimated energy consumption, the profile of simulated energy consumption can match the measured data. The simulation accuracy of room air temperature and energy consumption during the air-conditioner start-up period is not good and needs to be improved in future research. But in general, the verification shows that this energy consumption simulation method is acceptable for evaluating the energy performance of a room air-conditioner, and can also be a useful tool for commissioning room air-conditioners.

Wang, F.; Yoshida, H.; Matsumoto, K.

2006-01-01T23:59:59.000Z

109

Measure Guideline: Air Conditioner Diagnostics, Maintenance, and Replacement  

SciTech Connect

This guideline responds to the need for an efficient means of identifying, diagnosing, and repairing faults in air conditioning systems in existing homes that are undergoing energy upgrades. Inadequate airflow due to constricted ducts or undersized filters, improper refrigerant charge, and other system defects can be corrected at a fraction of the cost of equipment replacement and can yield significant savings. The guideline presents a two-step approach to diagnostics and repair.

Springer, D.; Dakin, B.

2013-03-01T23:59:59.000Z

110

Passive features for a liquid desiccant air conditioner  

SciTech Connect

A conceptual development program with the ultimate objective of substantially reducing or eliminating the parasitic power requirement for liquid sorbent air conditioning systems is described. Operational tests conducted on small prototypes have shown that some of the pumps can be replaced with other apparatus requiring no electrical energy. Experimental work has also shown that some electric utility dependent pumps might be replaced by solar powered pumps thus making the system more passive in nature.

Francis, C.E.; Beavers, D.R.

1980-01-01T23:59:59.000Z

111

A liquid over-feeding military air conditioner  

SciTech Connect

A 3-ton military air conditioning unit has been experimentally studied for baseline and liquid over-feeding operation (LOF). The test results indicate that LOF outperforms the baseline case over a wide ambient temperature range in terms of cooling capacity, power consumption, and system coefficient of performance (COP). At 95 F test point, the COP improvement for LOF is 19.8% over that of the baseline case. However, optimal refrigerant charge is essential for LOF to work properly.

Mei, V.C.; Chen, F.C. [Oak Ridge National Lab., TN (United States); Bolton, C. [Army CECOM Research, Development, and Engineering Center, Fort Belvoir, VA (United States)

1995-09-01T23:59:59.000Z

112

A liquid over-feeding military air conditioner  

SciTech Connect

A 3.3-ton military air conditioning unit has been studied experimentally in both baseline (as received) and as modified for liquid over-feeding (LOF) operation. Tne baseline test, using a proper refrigerant charge, showed the measured cooling capacity to be less than 1% off the rated capacity at 95{degrees}F ambient temperature. The test results indicate that LOF operation outperforms the baseline case over a wide ambient temperature range in terms of cooling capacity, power consumption, and system coefficient of performance (COP). At a 95{degrees}F test point, LOF operation has a cooling capacity of 51,100 BTU per hour, which is a 28.9% improvement over the baseline operation capacity of 39,600 BTU per hour. The COP for LOF at 95{degrees}F is 2.62, which is 29% better than the baseline COP of 2.03. However, an optimal refrigerant charge is essential for LOF to work properly.

Mei, V.C.; Chen, F.C.

1995-07-01T23:59:59.000Z

113

Effects of Air Conditioner Use on Real-World Fuel Economy  

Science Conference Proceedings (OSTI)

Vehicle data were acquired on-road and on a chassis dynamometer to assess fuel consumption under several steady cruise conditions and at idle. Data were gathered for various air conditioner (A/C) settings and with the A/C off and the windows open. Two vehicles were used in the comparisonstudy: a 2009 Ford Explorer and a 2009 Toyota Corolla. At steady speeds between 64.4 and 112.7 kph (40 and 70 mph), both vehicles consumed more fuel with the A/C on at maximum cooling load (compressor at 100% duty cycle) than when driving with the windows down. The Explorer maintained this trend beyond 112.7 kph (70 mph), while the Corolla fuel consumption with the windows down matched that of running the A/C at 120.7 kph (75 mph), and exceeded it at 128.7 kph (80 mph). The largest incremental fuel consumption rate penalty due to air conditioner use occurred was nearly constant with a weakslight trend of increasing consumption with increasing compressor (and vehicle) speed. Lower consumption is seenobserved at idle for both vehicles, likely due to the low compressor speed at this operating point

Huff, Shean P [ORNL; West, Brian H [ORNL; Thomas, John F [ORNL

2013-01-01T23:59:59.000Z

114

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

National Energy Consumption conditioner. National Energy Consumption When regulationsThe total energy consumption (NEC) of the national stock of

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

115

Energy savings and economics of advanced control strategies for packaged air conditioners with gas heat  

Science Conference Proceedings (OSTI)

This paper presents an evaluation of the potential energy savings from adding advanced control to existing packaged air conditioners. Advanced control options include air-side economizer, multi-speed fan control, demand control ventilation and staged cooling. The energy and cost savings from the different control strategies individually and in combination are estimated using the EnergyPlus detailed energy simulation program for four building types, namely, a small office building, a stand-alone retail building, a strip mall building and a supermarket building. For each of the four building types, the simulation was run for 16 locations covering all 15 climate zones in the U.S. The maximum installed cost of a replacement controller that provides acceptable payback periods to owners is estimated.

Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

2013-10-01T23:59:59.000Z

116

Investigations on Vapour Compression Air Conditioner with Direct Contact Desiccant Loop over Condenser and Evaporator  

E-Print Network (OSTI)

Perceived air quality increases when relative humidity is decreased till about 30% in the range of comfort temperature. In the present scenario, humidity is considered as a pollutant. Hence, a controlled environment not only at low temperature but also at low humidity is desired for many applications such as archives, data centers, etc. Either a separate dehumidifier or a precision air conditioning (AC) system needs to be employed for such an application. In fact, the latter forms a reheat AC system which happens to be energy inefficient. In view of this, a vapor compression window air conditioner is investigated with a superimposed liquid desiccant loop harnessing the advantages of both the compression system (high COP) and desiccant system (low humidity). Operation of such a novel system is explained, elucidating the operational feasibility. The results presented consider the characteristics of such a system with respect to changes in the evaporator inlet air temperature and humidity. The change in the specific humidity of air is compared for vapor compression system and the direct contact hybrid system for different values of inlet air temperature.

Maiya, M. P.; Ravi, J.; Tiwari, S.

2010-01-01T23:59:59.000Z

117

Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications: Preprint  

NLE Websites -- All DOE Office Websites (Extended Search)

A Zero Carryover A Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications Preprint A. Lowenstein AIL Research, Inc. S. Slayzak and E. Kozubal National Renewable Energy Laboratory To be presented at ASME International Solar Energy Conference (ISEC2006) Denver, Colorado July 8-13, 2006 Conference Paper NREL/CP-550-39798 July 2006 NOTICE The submitted manuscript has been offered by an employee of the Midwest Research Institute (MRI), a contractor of the US Government under Contract No. DE-AC36-99GO10337. Accordingly, the US Government and MRI retain a nonexclusive royalty-free license to publish or reproduce the published form of this contribution, or allow others to do so, for US Government purposes. This report was prepared as an account of work sponsored by an agency of the United States government.

118

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

NLE Websites -- All DOE Office Websites (Extended Search)

330E 330E Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement Josh Bode, Michael Sullivan, Joseph H. Eto January 2012 The work described in this report was funded by the Office of Electricity Delivery and Energy Reliability of the U.S. Department of Energy under Contract No. DE-AC02- 05CH11231. ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the University of California, nor any of their employees, makes any warranty, express or implied, or assumes any legal responsibility for the accuracy, completeness, or

119

Modeling of a second-generation solar-driven Rankine air conditioner. Final report  

DOE Green Energy (OSTI)

Ten configurations of a second-generation (2G), solar-powered, Rankine-driven air conditioner were simulated and the data presented for use in companion studies. The results of the analysis show that the boiling-in-collector (BIC) configuration generates more power per collector area than the other configurations. The models used to simulate the configuration are presented in this report. The generated data are also presented. Experimental work was done under this study to both improve a novel refrigerant and oil lubrication system for the centrifugal compressor and investigate the aerodynamic unloading characteristics of the centrifugal compressor. The information generated was used to define possible turbo-gearbox configurations for use in the second generation computer simulation.

Denius, M.W.; Batton, W.D.

1984-07-01T23:59:59.000Z

120

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

SciTech Connect

This report describes an analysis of the economic impacts of possible energy efficiency standards for commercial unitary air conditioners and heat pumps on individual customers in terms of two metrics: life-cycle cost (LCC) and payback period (PBP). For each of the two equipment classes considered, the 11.5 EER provides the largest mean LCC savings. The results show how the savings vary among customers facing different electricity prices and other conditions. At 11.5 EER, at least 80% of the users achieve a positive LCC savings. At 12.0 EER, the maximum efficiency analyzed, mean LCC savings are lower but still positive. For the {ge} $65,000 Btu/h to <135,000 Btu/h equipment class, 59% of users achieve a positive LCC savings. For the $135,000 Btu/h to <240,000 Btu/h equipment class, 91% of users achieve a positive LCC savings.

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-03-31T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Procuring High-Efficiency Air Conditioners: Harnessing Competition to Achieve Advances in Technology  

SciTech Connect

The Departments of Energy and Defense have joined forces to devise an innovative approach to acquiring more efficient unitary air conditioners that minimize life-cycle cost through improved technology. The resulting procurement solicitation challenges manufacturers to offer products with reduced life-cycle cost, taking into account both the initial prices of their units and the costs of their ongoing electric consumption. Competing products are evaluated according to a formula that reflects both full- and part-load efficiencies under a simulated set of time-varying climate conditions. The authors will report on the progress of the procurement, including the choice of target product based on market prospects and technology readiness, development of the technical specifications and electric consumption simulator, approaches to administrative and procedural challenges, responses from manufacturers, and plans for product promotion in the future.

Hollomon, J Bradford; Gordon, Kelly L.

2002-03-01T23:59:59.000Z

122

Central Air Conditioners","Heat Pumps","Individual Air Conditioners","District Chilled Water","Central Chillers","Packaged  

U.S. Energy Information Administration (EIA) Indexed Site

5. Cooling Equipment, Floorspace, 1999" 5. Cooling Equipment, Floorspace, 1999" ,"Total Floorspace (million square feet)" ,"All Buildings","All Cooled Buildings","Cooling Equipment (more than one may apply)" ,,,"Residential-Type Central Air Conditioners","Heat Pumps","Individual Air Conditioners","District Chilled Water","Central Chillers","Packaged Air Conditioning Units","Swamp Coolers","Other" "All Buildings ................",67338,58474,8329,9147,14276,2750,12909,36527,2219,1312 "Building Floorspace" "(Square Feet)" "1,001 to 5,000 ...............",6774,4879,890,700,962,"Q","Q",2613,253,"Q" "5,001 to 10,000 ..............",8238,6212,1606,707,1396,"Q","Q",3197,181,"Q"

123

NREL Solves Residential Window Air Conditioner Performance Limitations (Fact Sheet), Highlights in Research & Development, NREL (National Renewable Energy Laboratory)  

NLE Websites -- All DOE Office Websites (Extended Search)

13 Denver West Parkway 13 Denver West Parkway Golden, CO 80401 303-275-3000 | www.nrel.gov Printed with a renewable-source ink on paper containing at least 50% wastepaper, including 10% post consumer waste. NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Comprehensive performance tests lead to enhanced modeling capability and affordable methods to increase energy efficiency. Window air conditioners are inexpensive, portable, and can be installed by home occupants, making them a good solution for supplemental cooling, for installing air conditioning into homes that lack ductwork, and for renters. As a result, 7.5 million window air conditioners are purchased each year in the United States-more than all other home cooling equipment

124

Modeling the effects of Refrigerant Charging on Air Conditioner Performance Characteristics For Three Expansion Devices  

E-Print Network (OSTI)

An experimental and analytical study concerned with the off-design refrigerant charging of air conditioners is presented. A series of experiments were conducted to characterize the effects of refrigerant charge and type of expansion device on the system performance (capacity, EER, SEER, etc.) of an air conditioner. All experiments were performed according to the ASHRAE Standard [1983]. The effects of off-design refrigerant charge in the system, type of expansion device (capillary tube, TXV, and short-tube orifice), and outdoor dry-bulb temperature (82 to l00F) on the wet and dry steady state and cyclic tests are addressed in this study. The fully charged condition was established as a base case for all the expansion device systems. A full charge was obtained by charging the unit to the superheat or subcooled condition specified by the manufacturer charging chan. Once the full charge was determined, refrigerant was then added in 5% increments from -20% of full charge to +20% of full charge to cover the full range of charging conditions for a particular expansion device being tested. The investigation of off-design charging indicated that the system performance variables (total capacity, EER, and SEER) of the unit with capillary tube were more sensitive to off-design charging than the systems with TXV and short-tube orifice. From -20% to +20% charging, the capacity and EER showed a strong dependence on the outdoor temperature, but varied little with charge for the TXV and short-tube orifice expansion systems. A -20% charging resulted in a 21% reduction in SEER while a +20% charging produced an 11% reduction in SEER for the unit with capillary tube. For the TXV, SEER dropped 2% and 8% for -20% and +20% refrigerant charging, respectively. The SEER was constant at 9.4 for all the charging condition except for -5% charging where it peaked to 9.9 for the short-tube orifice expansion system. This trend would suggest that the range of sensitivity of a short-tube orifice system is confined within a small refrigerant charge. A new heat exchanger model based on tube-by-tube simulation was developed and integrated into the ORNL heat pump model. The model was capable of simulating the steady state response of a vapor compression air-to-air heat pump and air conditioner commonly used in residential applications. The simulated results were compared with laboratory tests at two outdoor temperatures. It was found that the ORNL model estimates were within an average of 3% of the experimental results from - 10% to +10% charging conditions. The model predicted the system performance up to 8% higher than measured results at +/-20% and +/-15% charging conditions. Among the eight void fraction models studied, the Hughmark model showed the best agreement between superheat and subcooled temperatures, refrigerant flow rate and capacity and the measured results.

Farzad, Mohsen

1990-08-01T23:59:59.000Z

125

DSP-Based Sensor-less Permanent Magnet Synchronous Motor Driver With Quasi-Sine PWM for Air-Conditioner Rotary Compressor.  

E-Print Network (OSTI)

??This thesis presented a sensor-less permanent magnet synchronous motor (PMSM) driver for controlling air-conditioner rotary compressor speed. In this thesis, a quasi-sine pulse-width modulation (PWM) (more)

Liu, Li-hsiang

2012-01-01T23:59:59.000Z

126

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

SciTech Connect

In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER.

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-10-10T23:59:59.000Z

127

The Impact of Codes, Regulations, and Standards on Split-Unitary Air Conditioners and Heat Pumps, 65,000 Btu/hr and Under  

Science Conference Proceedings (OSTI)

This document establishes a framework for understanding the technology and regulation of split-unitary air conditioners and heat pumps 65,000 Btu/hr and under. The reporting framework is structured so that it can be added to in the future. This study is broken into six chapters:The basic components, refrigeration cycle, operation, and efficiency ratings of split-unitary air conditioners and heat pumps are covered for background information.Equipment efficiency ...

2012-09-21T23:59:59.000Z

128

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

SciTech Connect

The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptive frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.

McNeil, Michael A.; Iyer, Maithili

2009-05-30T23:59:59.000Z

129

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

SciTech Connect

The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptive frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.

McNeil, Michael A.; Iyer, Maithili

2009-05-30T23:59:59.000Z

130

Modeled and measured effects of compressor downsizing in an existing air conditioner/heat pump in the cooling mode  

SciTech Connect

It is not uncommon to find oversized central air conditioners in residences. HVAC contractors sometimes oversize central air conditioners for one reason or another--some to the point that they may be 100% larger than needed to meet the load. Retrofit measures done to improve house envelope and distribution system efficiency also contribute to HVAC oversizing, as they reduce house heating and cooling loads. Proper sizing of an air conditioner or heat pump allows more efficient operation and provides a more comfortable environment than a highly oversized unit. Another factor that lowers operating efficiency is an improper refrigerant charge. Field inspections have revealed that about half of the units checked were not properly charged. An option available to homeowners with oversized air conditioners is to replace the existing compressor with a smaller, more efficient compressor, rather than purchasing a new, smaller unit. Such a retrofit may be economically justified, especially during a compressor failure, provided the oversizing of the existing unit is not too great. A used, 15-year old, single-package heat pump with a capillary tube expansion device on the indoor coil was purchased and tested in a set of environmental chambers to determine its cooling performance at various conditions. The system was also modeled to estimate its existing performance, and that with two different types of retrofitted state-of-the-art (SOA) efficient compressors with about 30% less capacity than the original compressor. This reduced the overall system cooling capacity by about 25%. Modeling estimated that the retrofit would increase system EER at 95 F by 30%, SEER by 34%, and reduce power demand by 39% compared to the existing unit. Reduced cycling losses account for the higher increase in SEER.

Levins, W.P.; Rice, C.K.; Baxter, V.D.

1996-05-01T23:59:59.000Z

131

The System Impact of Air-Conditioner Under-voltage Protection Schemes  

Science Conference Proceedings (OSTI)

This paper presents simulation results of evaluating an under-voltage protection scheme designed to take stalled air-conditioner (a/c) units offline such that the slow voltage recovery phenomena can be solved on areas heavily loaded with a/c motors during summer peak periods. A three feeder test-bed has been first used to quantify the effectiveness of the protection scheme and the sensitivity of the under-voltage relay settings. Then two real system events of the Western US power grid have been studied to evaluate the area impact of the protection scheme proposed by Southern California Edison. The study demonstrates that by taking all or most of the stalled a/c unit offline, the feeder voltage will recover in a few seconds, much quicker than the tens of seconds that the standard thermal relays imbedded in the motors need to trip the units. The drawback of the control scheme is that after the voltage recover, it settled at a higher voltage than before the faults because a large chuck of load has been shed.

Lu, Ning; Yang, Bo; Huang, Zhenyu; Bravo, Richard

2009-03-31T23:59:59.000Z

132

DOE Takes Action to Stop the Sales of Air-Con Air Conditioner...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

action against Air-Con, International, requiring the company to stop selling certain air conditioning systems in the U.S. that have been shown to violate minimum energy...

133

Performance of an experimental solar-driven absorption air conditioner. Annual report, July 1975--September 1976  

DOE Green Energy (OSTI)

An important pathway for the use of solar energy for space conditioning of buildings is the development of a heat-actuated air conditioner that can operate with the temperatures available from flat-plate solar collectors and use air cooling for disposal of the waste heat. The solar heating and cooling program of the Lawrence Berkeley Laboratory is exploring the use of the ammonia-water absorption cycle for this purpose. Results of the initial tests of an experimental system that has been fabricated to provide basic engineering data on the operation of the ammonia-water absorption cycle under such conditions are presented. A nominal three-ton, continuous operation, heat-actuated water chiller has been fabricated by drastic modification of a commercial gas-fired unit. The major modifications included designing a new water-heated generator, adding a preheater to the solution circuit, and increasing the flow rate of solution by a factor of about three. The unit was instrumented for measurement of temperatures, pressures, and solution concentrations at points in the circuit. Twenty-two experimental runs have been made and the results analyzed. An analysis of the thermodynamic cycle which includes the finite effectiveness of heat transfer at various points in the cycle is shown to predict with good accuracy the measured values of COP. The measured coefficient of performance agreed with the calculated values over the range 0.4 to 0.75 as the conditions of individual runs were varied. The agreement with the calculated values was within about 5 percent.

Dao, K.; Simmons, M.; Wolgast, R.; Wahlig, M.

1977-01-01T23:59:59.000Z

134

Simulation of Dehumidification Characteristics of High Efficiency Residential Central Air-Conditioners in Hot and Humid Climates  

E-Print Network (OSTI)

This study assesses the dehumidifying performance of the high efficiency residential central air conditioners (CAC) in hot/humid climates typified by that of Houston and Galveston. The performance study is based on such factors as: (i) weather (ii) thermostat set point and dead band, and (ill) sizing of unit relative to the design load of the residence. The units are evaluated on their ability to maintain conditions in the ASHRAE comfort zone in a typical residence in Houston area. The units, the thermostat, and the residence are simulated on a minute-by-minute basis using a commercial software (TRNSYS) after making certain modifications to it.

Katipamula, S.; O'Neal, D.; Somasundram, S.

1988-01-01T23:59:59.000Z

135

The Oklahoma Field Test: Air-conditioning electricity savings from standard energy conservation measures, radiant barriers, and high-efficiency window air conditioners  

SciTech Connect

A field test Involving 104 houses was performed in Tulsa, Oklahoma, to measure the air-conditioning electricity consumption of low-income houses equipped with window air conditioners, the reduction in this electricity consumption attributed to the installation of energy conservation measures (ECMS) as typically installed under the Oklahoma Weatherization Assistance Program (WAP), and the reduction achieved by the replacement of low-efficiency window air conditioners with high-efficiency units and the installation of attic radiant barriers. Air-conditioning electricity consumption and indoor temperature were monitored weekly during the pre-weatherization period (June to September 1988) and post-weatherization period (May to September 1989). House energy consumption models and regression analyses were used to normalize the air-conditioning electricity savings to average outdoor temperature conditions and the pre-weatherization indoor temperature of each house. The following conclusions were drawn from the study: (1) programs directed at reducing air-conditioning electricity consumption should be targeted at clients with high consumption to improve cost effectiveness; (2) replacing low-efficiency air conditioners with high-efficiency units should be considered an option in a weatherization program directed at reducing air-conditioning electricity consumption; (3) ECMs currently being installed under the Oklahoma WAP (chosen based on effectiveness at reducing space-heating energy consumption) should continue to be justified based on their space-heating energy savings potential only; and (4) attic radiant barriers should not be included in the Oklahoma WAP if alternatives with verified savings are available or until further testing demonstrates energy savings or other benefits in this typo of housing.

Ternes, M.P.; Levins, W.P.

1992-08-01T23:59:59.000Z

136

Experimental analysis of a window air conditioner with a R-22 and R32/R125/R134a mixture  

SciTech Connect

Much experimental and theoretical analysis of potential R-22 replacements has been accomplished. However, published information about the experimental analysis of any off-the-shelf air conditioner with a potential R-22 replacement at realistic, operating conditions is still rare. This type of work could be useful because it provides baseline data for comparing the performance of R-22 and its potential replacement at drop-in conditions. In this study, an off-the-shelf window air conditioner was tested at Air Conditioning and Refrigeration Institute (ARI)-rated indoor conditions and at different ambient temperatures, including the ARI-rated outdoor condition, with R-22 and with its potential replacement, a ternary mixture of R-32(30%)/R-125(10%)/R-134a(60%) (the ternary mixture). A test rig was built that provided for baseline operation and for the option of operating the system with a flooded evaporator by means of liquid over-feeding (LOF). The test results indicated the cooling capacity of the ternary mixture was 7.7% less than that of R-22 at 95{degrees}F ambient for baseline operation. The cooling capacity for both refrigerants improved when a flooded evaporator, or LOF, was used. For LOF operation, the cooling capacity of the ternary mixture was only 1.1% less than that of R-22. The ternary mixture had slightly higher compressor discharge pressure, a lower compressor discharge temperature, slightly lower compressor power consumption, and a higher compressor high/low pressure ratio.

Mei, V.C.; Chen, F.C.; Chen, D.T. [Oak Ridge National Lab., TN (United States); HuangFu, E.P. [USDOE, Washington, DC (United States)

1995-07-01T23:59:59.000Z

137

Analysis and design of a solar-powered liquid-desiccant air conditioner for use in hot and humid climates  

SciTech Connect

An experimental and theoretical investigation of the feasibility of a solar-powered liquid-desiccant air conditioner, for use in hot and humid climates, was carried out at the Mechanical Engineering Department, University of Florida. The proposed liquid desiccant system used nonadiabatic contactors, packed with finned-tube coils, for both moist air dehumidification and liquid-desiccant regeneration. A theoretical model was developed to analyze the complex phenomena of simultaneous heat and mass transfer in nonadiabatic contactors, as well as the continuous interaction between the dehumidification and regeneration processes. A computer code was written to assist in the analysis of the dehumidification and regeneration processes separately and coupled, for continuous operation. It was used to investigate the interaction between the different controlling parameters and their effects on the overall performance of the desiccant system. A fully solar-powered liquid-desiccant air-conditioner, with three tons of capacity was designed and optimized including economical criteria. The overall coefficient of performance (COP) of the optimized system was determined to be 0.312.

Chebbah, A.

1987-01-01T23:59:59.000Z

138

DOE/EA-1352: Environmental Assessment for Proposed Energy Conservation Standards for Residential Central Air Conditioners and Heat Pumps (12/00)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

52 52 ENVIRONMENTAL ASSESSMENT FOR PROPOSED ENERGY CONSERVATION STANDARDS FOR RESIDENTIAL CENTRAL AIR CONDITIONERS AND HEAT PUMPS December 2000 U.S. Department of Energy Assistant Secretary, Energy Efficiency & Renewable Energy Office of Building Research and Standards Washington, DC 20585 EA-i ENVIRONMENTAL ASSESSMENT FOR RESIDENTIAL CENTRAL AIR CONDITIONERS AND HEAT PUMPS TABLE OF CONTENTS 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EA-1 2.0 PURPOSE AND NEED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EA-1 3.0 ALTERNATIVES INCLUDING THE PROPOSED ACTION . . . . . . . . . . . . . . . . . EA-2 3.1 No Action Alternative . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EA-2 3.2 Proposed Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EA-3 3.3 Alternative Standards

139

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

Refrigeration and Air Conditioning Industry Association Junein the context of the air conditioning industry, the profileand improvement of the air conditioning industry and the

Zhou, Nan

2010-01-01T23:59:59.000Z

140

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network (OSTI)

Prices Computed from Air Conditioning Load Reductions UsingRefrigerating and Air-Conditioning Engineers, Inc. (ASHRAE)/Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE),

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Finding of No Significant Impact for Energy Conservation Standards for Residential Central Air Conditioners and Heat Pumps (01/01)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

01 01 Federal Register / Vol. 66, No. 14 / Monday, January 22, 2001 / Notices DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy Finding of No Significant Impact Energy Conservation Program for Consumer Products AGENCY: Department of Energy. ACTION: Finding of No Significant Impact (FONSI) for Energy Conservation Standard for Residential Central Air Conditioners and Heat Pumps. SUMMARY: The Energy Policy and Conservation Act, as amended by the National Energy Conservation Policy Act and the National Appliance Energy Conservation Act, and the National Appliance Energy Conservation Amendments, prescribes energy conservation standards for certain major household appliances, and requires the Department of Energy (DOE) to administer an energy conservation program for these products. Based on an

142

Retrofitting an automotive air conditioner with HFC-134a, additive, and mineral oil. Final report, October 1992-May 1994  

Science Conference Proceedings (OSTI)

The paper gives results of an evaluation of a lubricant additive developed for use in retrofitting motor vehicle air conditioners. The additive was designed to enable HFC-134a to be used as a retrofit refrigerant with the existing mineral oil in CFC-12 systems. The goal of the project was to provide preliminary feasibility testing of the additive. The cooling effect of the test system retrofitted with HFC-134a and the oil additive was nearly the same as that of the original system with CFC 12 refrigerant. If lubricant additives prove to be successful, miscible lubricants may not be needed for retrofitting some automotive systems. The retrofitting procedure might be simplified and the cost to consumers might be reduced. It has not been determined if retrofitting systems with HFC-134a and oil additives is feasible for a wider range of operating conditions and types of equipment, including the applicability of orifice tube/suction accumulator systems.

Jetter, J.J.; Delafield, F.R.

1994-05-01T23:59:59.000Z

143

Central Air Conditioning | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Central Air Conditioning Central Air Conditioning Central Air Conditioning May 30, 2012 - 8:01pm Addthis Central air conditioners circulate cool air through a system of supply and return ducts. | Photo courtesy of ©iStockphoto/DonNichols. Central air conditioners circulate cool air through a system of supply and return ducts. | Photo courtesy of ©iStockphoto/DonNichols. What does this mean for me? Central air conditioning systems are thermostatically controlled and convenient to use. Central air conditioning systems must be installed properly to operate efficiently. Central air conditioning systems can share ductwork with your heating system. Central air conditioners circulate cool air through a system of supply and return ducts. Supply ducts and registers (i.e., openings in the walls,

144

Air Reverse Circulation Bit Internal Fluid Simulation Based on CFD  

Science Conference Proceedings (OSTI)

The article instructs the work principle of the injector device and its application in the reverse-circulation sampling drilling bit. Then use the fluent fluid engineering emulator software to simulate the internal fluid territory of the injector when ... Keywords: air reverse circulation, bit, injector hole, optimization

Shuqing Hao; Hong-wei Huang; Kun Yin

2009-07-01T23:59:59.000Z

145

A cost-effective and fuel-conserving nonelectric air conditioner that combines engine-driven compression and absorption cycles  

SciTech Connect

A natural-gas-fueled electricity-producing condensing furnace with the potential of being mass produced at a cost of less than $1000 and providing a cost-effective and highly fuel-conserving alternative to virtually every residential gas furnace in the world has been developed. While this is a new system, it completely consists of existing mass-produced components including single-cylinder air-cooled engines, induction motors/generators, and control devices. Thus, timely commercialization can be expected and an important new energy technology and industry can result. However, all the benefits of this electricity-producing furnace occur during the winter. This has stimulated the search for a new system that can provide comparable benefits in terms of fuel conservation, the environment, and electric utility peak reduction during the summer, along with the prospects of a new and efficient new use for the natural gas surpluses that occur during the summer. The resulting system, which can use existing component equipment, is a commercial-size nonelectric air conditioner that consists of an automobile-type engine converted to natural gas, or possibly a diesel or combustion turbine, driving a Freon compression cycle, with virtually all of the engine reject heat from the exhaust and from the engine cooling system driving a conventional absorption air conditioning cycle.

Wicks, F.

1988-01-01T23:59:59.000Z

146

The Influence of Operating Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner  

E-Print Network (OSTI)

A field investigation was carried out in an office building of Changsha city in winter and summer, the influence of different running modes, curtain styles and room temperature set point on energy consumption of room air conditioner (RAC) was studied. The results show that: In summer automatic speed mode consumes the least refrigerating energy in different running modes, compared with low speed and high speed modes, it can conserve energy for 27.3% and 15.8%, respectively. In the same running mode, setting outer curtain can conserve energy for 40.9% and 20.4% compared with no curtain and inner curtain states, respectively. In winter high speed mode is the most efficient for saving energy which can decrease 40.3% and 30.9% compared with low speed and automatic speed modes. In the same running mode, setting inner curtain state makes the least heating energy consumption in cloudy day, about 10.8% and 2.7% less than no curtain and outer curtain states. However, it is not obvious when the day is fine. The heating energy consumption decreases as room temperature set point falls, compared with the energy consumption at 20.5 C and 19.5 C, it is decreases for 34.1% and17.0 % at 18.5 C, respectively. All the results will be the reference of environment design and control for air conditioning room.

Yu, J.; Yang, C.; Guo, R.; Wu, D.; Chen, H.

2006-01-01T23:59:59.000Z

147

An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with a Thermal Expansion Valve  

E-Print Network (OSTI)

The effect of the improper charging on steady state and cyclic performance (capacity, EER, power consumption, SEER, and coefficient of degradation) of a residential air conditioner which utilized a thermal expansion valve was investigated. This study was the continuation of ESL/CON/88-1 performed by Mohsen Farzad and Dennis O'Neal. A fully charged condition was established as a base case. The full charge was obtained by charging the unit to the subcooling specified by the manufacturer for a specific indoor and outdoor temperatures. Once the full charge was determined, the unit was subjected to 40%, 30%, 20%, 15%, 10%, and 5% undercharging and 5%, 10%, 15%, and 20% overcharging of refrigerant by mass. The fully charged tests were compared to those for under and overcharging. The performance of the unit was evaluated as a function of charge as well as at four outdoor room temperatures (82F, 90F, 95F, and 100F). As the outdoor temperature increased, the total capacity and EER dropped. The maximum total capacity, EER, and SEER were found at 10% undercharging (12 6 oz). The capacity and efficiency (EER and SEER) of the unit were found to be less sensitive to under/overcharging than the unit with a capillary tube expansion previously studied. Other data such as refrigerant flow rate, sensible heat ratio, superheat and subcooling were also presented.

Farzad, M.; O'Neal, D. L.

1989-01-01T23:59:59.000Z

148

An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with Capillary Tube Expansion  

E-Print Network (OSTI)

The effect of the improper charging on the performance (capacity, EER, power consumption, SEER, and coefficient of degradation) of a residential air conditioner during the steady state (wet and dry coils) and cycling operation was investigated. The fully charged condition was established as a base case. A full charge was obtained charging the unit to the superheat specified by the manufacturer's charging chart for specific set of indoor and outdoor temperatures. Once the full charge was determined, the unit was subjected to 20%, 15%, 10%, and 5% under and overcharging of refrigerant (by mass). The fully charged tests were compared to under and overcharging. The performance of the unit was evaluated as a function of charge as well as at four outdoor room temperatures (82F, 90F, 95F, and 100F). As the outdoor temperature increased, the total capacity and EER dropped. The investigation of improper charging showed that the total capacity, EER, and SEER were more sensitive to undercharging than overcharging conditions. A 20% undercharge resulted in a 21% reduction in SEER while a 20% overcharge produced a 11% reduction in SEER. Other data such as refrigerant flow rate, sensible heat ratio, superheat and subcooling are also presented.

Farzad, M.; O'Neal, D. L.

1988-01-01T23:59:59.000Z

149

Effects of system cycling, evaporator airflow, and condenser coil fouling on the performance of residential split-system air conditioners  

E-Print Network (OSTI)

Three experimental studies were conducted to quantify the effects of system cycling, evaporator airflow, and condenser coil fouling on the performance of residential air conditioners. For all studies, the indoor dry-bulb (db) temperature was 80F (26.7C) db. The cycling study consisted of twelve transient tests conducted with an outdoor temperature of 95F (35C) db for cycle times of 6, 10, 15, and 24 minutes. Indoor relative humidities of 40%, 50%, and 60% were also considered. The evaporator airflow study consisted of twenty-four steady-state tests conducted with an indoor condition of 67F (19.4C) wet-bulb (wb) for evaporator airflows ranging from 50% below to 37.5% above rated airflow. Outdoor temperatures of 85F (29.4C) db, 95F (35C) db, and 105F (40.6C) db were also considered. The coil fouling study used a total of six condensers that were exposed to an outdoor environment for predetermined amounts of time and tested periodically. Three of the condensers were cleaned and retested during the periodic testing cycles. Testing consisted of thirty-three steady-state tests conducted with an indoor condition of 67F (19.4C) wb for outdoor exposure times of 0, 2000, 4000, and 8000 hours. Outdoor temperatures of 82F (27.8C) db and 95F (35C) db were also considered.

Dooley, Jeffrey Brandon

2004-12-01T23:59:59.000Z

150

Fault detection methods for vapor-compression air conditioners using electrical measurements  

E-Print Network (OSTI)

(cont.) This method was experimentally tested and validated on a commercially available air handler and duct system. In the second class of faults studied, liquid refrigerant, rather than vapor, enters the cylinder of a ...

Laughman, Christopher Reed.

2008-01-01T23:59:59.000Z

151

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network (OSTI)

avoid bias in the electricity bill calculations, we assignedarrive at an annual electricity bill. The difference betweenbill and multiplied it by the ratio of the total air conditioning energy use to the total building electricity

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

152

Preliminary design package for residential heating/cooling system--Rankine air conditioner redesign  

DOE Green Energy (OSTI)

This report contains a summary of the preliminary redesign and development of a marketable single-family heating and cooling system. The objectives discussed are the interim design and schedule status of the Residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.

Not Available

1978-12-01T23:59:59.000Z

153

Monitoring the Performance of a Residential Central Air Conditioner under Degraded Conditions on a Test Bench  

E-Print Network (OSTI)

This report presents the measured degradation in performance of a residential air conditioning system operating under degraded conditions. Experiments were conducted using a R-22 threeton split-type cooling system with a short-tube orifice expansion device. Results are presented here for a series of tests in which the various commonly occurring degraded conditions were simulated on a test bench. At present, very little information is available which quantifies the performance of a residential cooling system operating under degraded conditions. Degraded performance measurements can provide information which could help electric utilities evaluate the potential impact of systemwide maintenance programs. This report also discuss the development of a diagnostic procedure based on measurement of refrigerant and air side temperatures.

Palani, M.; O'Neal, D. L.; Haberl, J. S.

1992-01-01T23:59:59.000Z

154

Comparison of the performance of open cycle air conditioners utilizing rotary desiccant dehumidifiers  

DOE Green Energy (OSTI)

This paper presents the results of an investigation of open cycle cooling systems using rotary desiccant dehumidifiers. Three systems, the ventilation, recirculation, and Dunkle cycles have been modeled. The performance of these systems coupled with an air-based solar system has been determined using TRNSYS simulations of system operation in four representative US climates. The system COP, fraction of the total cooling load met by the desiccant system, and fraction of the thermal energy provided by solar energy are compared. An assessment of the effect of climate and system parameters on the relative performance of the three system configurations is made. It is shown that in order to meet residential loads of 7 to 11 kW with a COP on the order of unity, systems with high effectiveness must be employed. These systems were also found to perform well when operated solely with a solar thermal input.

Jurinak, J.J.; Beckman, W.A.

1985-01-01T23:59:59.000Z

155

Seasonal efficiencies of residential heat pump air conditioners with inverter-driven compressors  

SciTech Connect

This paper describes a study to experimentally determine the steady-state characteristics, cyclic effect, and frosting/defrosting effect of a inverter heat pump currently available on the Japanese market and compute its seasonal efficiency based on the local outdoor air temperature data. It has been found that the APF of this heat pump is higher by 15% than that of the conventional fixed-speed heat pump. If cyclic and frosting/defrosting losses are eliminated, the APF of the inverter heat pump will be further improved by 2% to 6%. For the evaluation of an inverter heat pump, APF alone is not sufficient, and an additional parameter such as an annual comfort factor (ACF) is needed.

Hori, M.; Akamine, I.; Sakai, T.

1985-01-01T23:59:59.000Z

156

Effect of refrigerant charge, duct leakage, and evaporator air flow on the high temerature performance of air conditioners and heat pumps  

E-Print Network (OSTI)

An experimental study was conducted to quantify the effect of several installation items on the high outdoor ambient temperature performance of air conditioners. These installation items were: improper amount of refrigerant charge, reduced evaporator airflow, and return air leakage from hot attic spaces. There were five sets of tests used for this research: two of them for the charging tests, two for the reduced evaporator airflow, and one for the return air leakage tests. For the charging tests, the indoor room conditions were 80'F (27.8'C) dry-bulb and 50% relative humidity. The outdoor conditions ranged from 95'F (350C) all the way up to 120'F (48.9'C). Charge levels ranged from 30% undercharged to 40% overcharged for the short-tube orifice unit. For the thermal expansion valve (TXV) unit, charge levels ranged from-36% charging to +27% charging. Performance was quantified with the following variables: total capacity, energy efficiency ratio (EER), and power. The performance of the orifice unit was more sensitive to charge than it was for the TXV unit. For the TXV unit on the -27% to +27% charging range, the capacity and EER changed little with charge. A TXV unit and a short-tube orifice unit were also tested for reduced evaporator airflow. As evaporator airflow decreased, the capacity and EER both decreased as expected. However, the drop was not as significant as with the charging tests. For the extreme case of 50% reduced evaporator airflow, neither unit's capacity or EER dropped more than 25%. Return air leakage from hot attic spaces was simulated by assuming adiabatic mixing of the indoor air at normal conditions with the attic air at high temperatures. Effective capacity and EER both decreased with increased return air leakage. However, power consumption was relatively constant for all variables except outdoor temperature, which meant that for the same power consumption, the unit delivered much lower performance when there was return air leakage. The increase in sensible heat ratio (SHR) with increasing leakage showed perhaps the most detrimental effect of return air leakage on performance, which was the inability of the unit to absorb moisture from the environment.

Rodriguez, Angel Gerardo

1995-01-01T23:59:59.000Z

157

Effect of Refrigerant Charge, Duct Leakage, and Evaporator Air Flow on the High Temperature Performance of Air Conditioners and Heat Pumps  

E-Print Network (OSTI)

An experimental study was conducted to quantify the effect of several installation items on the high outdoor ambient temperature performance of air conditioners. These installation items were: improper amount of refrigerant charge, reduced evaporator airflow, and return air leakage from hot attic spaces. There were five sets of tests used for this research: two of them for the charging tests, two for the reduced evaporator airflow, and one for the return air leakage tests. For the charging tests, the indoor room conditions were 80F (27.8C) dry-bulb and 50% relative humidity. The outdoor conditions ranged from 95F (35C) all the way up to 120F (48.9C). Charge levels ranged from 30% undercharged to 40% overcharged for the short-tube orifice unit. For the thermal expansion valve (TXV) unit, charge levels ranged from -36% charging to +27% charging. Performance was quantified with the following variables: total capacity, energy efficiency ratio (EER), and power. The performance of the orifice unit was more sensitive to charge than it was for the TXV unit. For the TXV unit on the -27% to +27% charging range, the capacity and EER changed little with charge. A TXV unit and a short-tube orifice unit were also tested for reduced evaporator airflow. As evaporator airflow decreased, the capacity and EER both decreased as expected. However, the drop was not as significant as with the charging tests. For the extreme case of 50% reduced evaporator airflow, neither unit's capacity or EER dropped more than 25%. Return air leakage from hot attic spaces was simulated by assuming adiabatic mixing of the indoor air at normal conditions with the attic air at high temperatures. Effective capacity and EER both decreased with increased return air leakage. However, power consumption was relatively constant for all variables except outdoor temperature, which meant that for the same power consumption, the unit delivered much lower performance when there was return air leakage. The increase in sensible heat ratio (SHR) with increasing leakage showed perhaps the most detrimental effect of return air leakage on performance, which was the inability of the unit to absorb moisture from the environment.

Rodriguez, Angel Gerardo

2007-11-29T23:59:59.000Z

158

An Investigation of Alternative Methods for Measuring Static Pressure of Unitary Air Conditioners and Heat Pumps  

E-Print Network (OSTI)

This project was created to address an important issue currently faced by test facilities measuring static pressure for air-conditioning and heat pumps. Specifically, ASHRAE Standard 37, the industry standard for test setup, requires an outlet duct of a certain length, based on the unit outlet geometry, and this ducting added to the unit height may result in a test apparatus height that exceeds psychometric test room dimensions. This project attempted to alter the outlet duct in a way that reduces the test apparatus height while maintaining the reliability of the ASHRAE Standard 37 testing setup. The investigation was done in two scenarios, the first, which altered the direction of the flow after the unit with an elbow and measured static pressure downstream of the elbow, and the second which inserted a passive resistive piece in the flow to decrease the required distance between the unit and the static pressure measurement. Three air handling units were used in Scenario 1 and Scenario 2 testing, with the two smallest units additionally being tested in Scenario 1 with an over-sized duct. The scenario tests were required to be within 5% power and 2.5% airflow of a baseline test following ASHRAE Standard 37. he results for Scenario 1 have shown that ASHRAE Standard 37 can be modified to reduce testing height restrictions by using a square elbow with turning vanes, provided it is oriented in a specific way in relation to the blower. Furthermore, additional Scenario 1 testing on the over-sized outlet duct shows that possibilities exist for using a single over-sized duct to successfully meet ASHRAE Standard 37 testing conditions when testing a variety of units. Finally, the results of Scenario 2 have shown that the height constraints of the outlet duct can be reduced by installing a passive resistive device consisting of a mesh at the outlet; however, this approach applies only to those units with the heat exchanger located downstream of the blower. As a result of specific issues or problems that were encountered during the project that were beyond the scope, eleven case studies were presented and recommended for future work.

Wheeler, Grant Benson

2013-08-01T23:59:59.000Z

159

High-Efficiency Variable Dehumidification for Air Conditioners: ClimaStat  

SciTech Connect

Advantek has successfully developed the first low-cost technology offering significant improvement in both Seasonal Energy Efficiency (SEER) and comfort & humidity control. A production prototype was constructed based on a commercial roof top package unit. The prototype was operated under a wide range of psychrometric conditions. Test data was analyzed to identify refinements, which were implemented to further improve performance in an iterative procedure that resulted in a fully optimized technology. The latest results show an increase in dehumidification capacity of 56% with ClimaStat in full dehumidify mode vs. with ClimaStat off. Dehumidification improved by a factor of 1.7 to 1.9 meaning that the unit can provide nearly twice the water removal per unit of sensible cooling load. Performance testing results have been consistent, verifiable and repeatable. . ClimaStat cost-effectively controls humidity on-demand and improves indoor air quality while reducing annual energy costs. Test data clearly shows that ClimaStat costs 20% to 60% less to operate. ClimaStat is ready for market.

West, Michael K., Ph.D. P.E.

2006-04-30T23:59:59.000Z

160

Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study  

SciTech Connect

The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The performance degradation of R410A at higher temperatures was greater than R22. However, the R22 and R410A systems both operated normally during all tests. Visual observations of the R410A system provided no indication of vibrations or TXV hunting at high ambient outdoor test conditions with the compressor operating in the transcritical regime.

Piotr A. Domanski; W. Vance Payne

2002-10-31T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study  

SciTech Connect

The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The performance degradation of R410A at higher temperatures was greater than R22. However, the R22 and R410A systems both operated normally during all tests. Visual observations of the R410A system provided no indication of vibrations or TXV hunting at high ambient outdoor test conditions with the compressor operating in the transcritical regime.

Piotr A. Domanski; W. Vance Payne

2002-10-31T23:59:59.000Z

162

Experimental study of a R-407C drop-in test on an off-the-shelf air conditioner with a counter-cross-flow evaporator  

SciTech Connect

An off-the-shelf 2-ton window air conditioner having an energy efficiency ratio of 10 was used to perform a drop-in test with R-407C. Laboratory tests were performed using a parallel-cross-flow (PCF) evaporator and a counter-cross-flow (CCF) evaporator. The CCF configuration is designed to take advantage of the temperature glide of R-407C so that the warm evaporator inlet air will be in contact with the higher temperature part of the evaporator coils first. The test results indicated that, at the Air Conditioning and Refrigeration Institute-rated indoor and outdoor conditions, the cooling capacity was 8% higher and system coefficient of performance about 3.8% higher for the CCF evaporator than for the PCF evaporator. The test results also showed that the latent load for CCF was 30.6% higher than for PCF. The far better dehumidification effect provided by the CCF evaporator design is desirable for areas where the latent load is high. The experimental findings should be useful for future efforts to design a dehumidifier that uses a zeotropic refrigerant that provides a significant temperature glide. R-22 test data from a previous project are included as a reference.

Mei, V.C.; Domitrovic, R.; Chen, F.C.

1998-03-01T23:59:59.000Z

163

PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976  

E-Print Network (OSTI)

F for removing heat from the condenser and absorber coils.temperature. Air-cooled condensers and absorbers are limitedfor water- cooling the condenser was an overriding concern

Dao, K.

2010-01-01T23:59:59.000Z

164

Solar-Powered, Liquid-Desiccant Air Conditioner for Low-Electricity Humidity Control: Report and Summary Report  

DOE Green Energy (OSTI)

The primary objective of this project was to demonstrate the capabilities of a new high-performance, liquid-desiccant dedicated outdoor air system (DOAS) to enhance cooling efficiency and comfort in humid climates while substantially reducing electric peak demand at Tyndall Air Force Base (AFB), which is 12 miles east of Panama City, Florida.

Dean, J.; Kozubal, E.; Herrmann, L.; Miller, J.; Lowenstein, A.; Barker, G.; Slayzak, S.

2012-11-01T23:59:59.000Z

165

PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976  

E-Print Network (OSTI)

Size and Type of the Heat Exchangers Air Cooled Condensora packed-tower counterflow heat exchanger for the generator.to strong solution heat exchanger) was added. iv. The

Dao, K.

2010-01-01T23:59:59.000Z

166

Numerical method for computing nonlinear, time dependent, buoyant circulation of air in rooms  

Science Conference Proceedings (OSTI)

A method is described which solves the dynamic equations for air circulation at Grashof numbers that are in the range of environmental temperatures of rooms. Previous two-dimensional computation techniques were limited to G ? 105 ...

J. E. Fromm

1971-05-01T23:59:59.000Z

167

Relationship between AirSea Density Flux and Isopycnal Meridional Overturning Circulation in a Warming Climate  

Science Conference Proceedings (OSTI)

This study aims to explore the relationship between airsea density flux and isopycnal meridional overturning circulation (MOC), using the Intergovernmental Panel on Climate Change (IPCC) Fourth Assessment Report (AR4) model projections of the ...

MyeongHee Han; Igor Kamenkovich; Timour Radko; William E. Johns

2013-04-01T23:59:59.000Z

168

NREL Demonstrates Game-Changing Air Conditioner Technology (Fact Sheet), Highlights in Research & Development, NREL (National Renewable Energy Laboratory)  

NLE Websites -- All DOE Office Websites (Extended Search)

Testing of DEVAP prototype validates modeled Testing of DEVAP prototype validates modeled predictions of 40% to 85% energy savings. Researchers in the NREL Buildings group are moving the award-winning desiccant enhanced evaporative (DEVAP) air conditioning technol- ogy further toward commercialization by demonstrating that its energy-saving perfor- mance matches closely with thermodynamic model predictions. Industry partners Synapse Product Development and AIL Research built two prototypes of DEVAP based on NREL's design and modeling, which were tested in NREL's Advanced HVAC Systems Laboratory. Experiments added confidence to the predicted energy savings of 40% in humid climates and 85% in dry climates, empowering the model as a tool for developing marketable designs, and illustrating the potential of DEVAP to transform

169

Central Air Conditioners","Heat Pumps","Individual Air Conditioners...  

U.S. Energy Information Administration (EIA) Indexed Site

4,89,294,9,26,327,47,4 "District Heat ...",96,77,3,4,16,39,15,35,"Q","Q" "Boilers ...",581,474,58,39,211,3,96,223,18,14 "Packaged Heating Units...

170

Air Conditioning with Magnetic Refrigeration : An Efficient, Green Compact Cooling System Using Magnetic Refrigeration  

SciTech Connect

BEETIT Project: Astronautics is developing an air conditioning system that relies on magnetic fields. Typical air conditioners use vapor compression to cool air. Vapor compression uses a liquid refrigerant to circulate within the air conditioner, absorb the heat, and pump the heat out into the external environment. Astronautics design uses a novel property of certain materials, called magnetocaloric materials, to achieve the same result as liquid refrigerants. These magnetocaloric materials essentially heat up when placed within a magnetic field and cool down when removed, effectively pumping heat out from a cooler to warmer environment. In addition, magnetic refrigeration uses no ozone-depleting gases and is safer to use than conventional air conditioners which are prone to leaks.

None

2010-09-01T23:59:59.000Z

171

Candidate chemical systems for air cooled, solar powered, absorption air conditioner design. Part III. Lithium salts with anti-freeze additives  

DOE Green Energy (OSTI)

The two most promising anti-solidification additives which have been identified are ethanolamine and ethylene glycol. Considerations of viscosity, corrosion, crystallization temperature and vapor pressure have led to a selection of lithium bromide - ethylene glycol - water as the basis of a prototype air-cooled machine, with the lithium bromide; ethylene glycol ratio being 4.5. Using what appear to be reasonable heat exchanger approach temperatures, cycle thermal COP's of 0.7/sup +/ appear possible at the specified design point, based on solution properties which were determined with qualification accuracy. The prototype, delivering 10,000 watts of cooling, has a calculated parasitical electrical load of about 175 watts (theoretical) to drive the internal fans and pumps, equivalent to about a 0.5 horsepower motor.

Biermann, W.J.

1978-06-01T23:59:59.000Z

172

Utilization of ventilation air methane as a supplementary fuel at a circulating fluidized bed combustion boiler  

Science Conference Proceedings (OSTI)

Ventilation air methane (VAM) accounts for 60-80% of the total emissions from underground coal mining activities in China, which is of serious greenhouse gas concerns as well as a waste of valuable fuel sources. This contribution evaluates the use of the VAM utilization methods as a supplementary fuel at a circulating fluidized bed combustion boiler. The paper describes the system design and discusses some potential technical challenges such as methane oxidation rate, corrosion, and efficiency. Laboratory experimentation has shown that the VAM can be burnt completely in circulated fluidized bed furnaces, and the VAM oxidation does not obviously affect the boiler operation when the methane concentration is less than 0.6%. The VAM decreased the incomplete combustion loss for the circulating fluidized bed combustion furnace. The economic benefit from the coal saving insures that the proposed system is more economically feasible. 17 refs., 3 figs., 1 tab.

Changfu You; Xuchang Xu [Tsinghua University, Beijing (China). Key Laboratory for Thermal Science and Power Engineering of Ministry of Education

2008-04-01T23:59:59.000Z

173

A Homeowners Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet), Building America Case Study: Technology Solutions for Existing Homes, Building Technologies Office (BTO)  

NLE Websites -- All DOE Office Websites (Extended Search)

Homeowners in the United States spend Homeowners in the United States spend one out of every eight dollars of utility costs on cooling their living space. Window air conditioners (A/Cs) are an inexpensive alternative to central systems, and are sold in greater numbers each year than all other residential cooling systems. They are purchased to cool a specific room and are easy for anyone to install. In contrast to these benefits, window A/Cs come at a cost-they operate less efficiently (using more energy to do the same cooling) than most other residential A/C systems. Researchers at the National Renewable Energy Laboratory (NREL) studied window A/Cs on behalf of the U.S.

174

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology  

SciTech Connect

The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

Not Available

1993-11-01T23:59:59.000Z

175

On the Role of Interior Mixing and Air-Sea Fluxes in Determining the Stratification and Circulation of the Oceans  

Science Conference Proceedings (OSTI)

The problem of determining the (eastern boundary) basic stratification and the buoyancy-driven circulation of the oceans is addressed. A global integral constraint relating the interior stratification and the air-sea heat fluxes is derived, based ...

Eli Tziperman

1986-04-01T23:59:59.000Z

176

Tropical AirSea Interactions Accelerate the Recovery of the Atlantic Meridional Overturning Circulation after a Major Shutdown  

Science Conference Proceedings (OSTI)

Using a coupled oceansea iceatmosphere model of intermediate complexity, the authors study the influence of airsea interactions on the stability of the Atlantic Meridional Overturning Circulation (AMOC). Mimicking glacial Heinrich events, a ...

Uta Krebs; A. Timmermann

2007-10-01T23:59:59.000Z

177

Air Conditioning | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Conditioning Conditioning Air Conditioning July 1, 2012 - 6:28pm Addthis Air conditioners cost U.S. homeowners more than $11 billion each year, and regular maintenance can keep your air conditioner running efficiently. | Photo courtesy of ©iStockphoto/JaniceRichard Air conditioners cost U.S. homeowners more than $11 billion each year, and regular maintenance can keep your air conditioner running efficiently. | Photo courtesy of ©iStockphoto/JaniceRichard How does it work? An air conditioner uses energy -- usually electricity -- to transfer heat from the interior of your home to the relatively warm outside environment. Two-thirds of all homes in the United States have air conditioners. Air conditioners use about 5% of all the electricity produced in the United States, at an annual cost of more than $11 billion to homeowners. As a

178

Homeowner's Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet), Building America Case Study: Technology Solutions for Existing Homes, Building Technologies Office (BTO)  

SciTech Connect

This fact sheet offers a step-by-step guide to proper installation of window air conditioning units, in order to improve efficiency and comfort for homeowners.

Not Available

2013-06-01T23:59:59.000Z

179

Federal Energy Management Program: Covered Product Category: Room Air  

NLE Websites -- All DOE Office Websites (Extended Search)

Room Air Conditioners to someone by E-mail Room Air Conditioners to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Facebook Tweet about Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Twitter Bookmark Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Google Bookmark Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Delicious Rank Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Digg Find More places to share Federal Energy Management Program: Covered Product Category: Room Air Conditioners on AddThis.com... Energy-Efficient Products Federal Requirements Covered Product Categories Product Designation Process

180

Air Conditioning | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

environment. An air conditioner uses a cold indoor coil called the evaporator. The condenser, a hot outdoor coil, releases the collected heat outside. The evaporator and...

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

EVALUATION OF A NEW SOLAR AIR CONDITIONER  

E-Print Network (OSTI)

with Dennis Hughes, FNBO, 2010. 9. U.S. EPA, eGrid 2007 Version 1.1, Year 2005 Summary Tables, Region MRO West (fossil fuel output). http://www. epa.gov/cleanenergy/energy-resources/ egrid/index.html (accessed

182

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and unnecessary expense. Set the fan speed on high, except on very humid days. When humidity is high, set the fan speed on low for more comfort. The low speed on humid days will...

183

Regional Climates in the GISS General Circulation Model: Surface Air Temperature  

Science Conference Proceedings (OSTI)

One of the more viable research techniques into global climate change for the purpose of understanding the consequent environmental impacts is based on the use of general circulation models (GCMs). However, GCMs are currently unable to reliably ...

Bruce Hewitson

1994-02-01T23:59:59.000Z

184

List of Compressed air Incentives | Open Energy Information  

Open Energy Info (EERE)

Energy Efficiency Incentive Program (Texas) Local Grant Program Texas Commercial Ceiling Fan Central Air conditioners Chillers Comprehensive MeasuresWhole Building Compressed air...

185

Low-noise pulse conditioner  

DOE Patents (OSTI)

A low-noise pulse conditioner is provided for driving electronic digital processing circuitry directly from differentially induced input pulses. The circuit uses a unique differential-to-peak detector circuit to generate a dynamic reference signal proportional to the input peak voltage. The input pulses are compared with the reference signal in an input network which operates in full differential mode with only a passive input filter. This reduces the introduction of circuit-induced noise, or jitter, generated in ground referenced input elements normally used in pulse conditioning circuits, especially speed transducer processing circuits. This circuit may be used for conditioning the sensor signal from the Fidler coil in a gas centrifuge for separation of isotopic gaseous mixtures.

Bird, D.A.

1981-06-16T23:59:59.000Z

186

Do Changes in the Midlatitude Circulation Have Any Impact on the Arctic Surface Air Temperature Trend?  

Science Conference Proceedings (OSTI)

The warming of the near-surface air in the Arctic region has been larger than the global mean surface warming. There is general agreement that the Arctic amplification of the surface air temperature (SAT) trend to a considerable extent is due to ...

R. G. Graversen

2006-10-01T23:59:59.000Z

187

Air-Con International: Noncompliance Determination and Proposed...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

to Air-Con International finding that a variety of central air conditioners and air conditioning heat pumps distributed under the Air-Con private label do not comport...

188

HEATING, AIR-CONDITIONING AND REFRIGERATION DISTRIBUTORS INTERNATIONAL (HARDI)  

Energy.gov (U.S. Department of Energy (DOE))

OE Framework Document and Stakeholder Meeting regarding the Enforcement of the updated Energy Conservation Standards for Air Conditioners, Furnaces and Heat Pumps.

189

Air-Conditioning Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air-Conditioning Basics Air-Conditioning Basics Air-Conditioning Basics August 16, 2013 - 1:59pm Addthis Air conditioning is one of the most common ways to cool homes and buildings. How Air Conditioners Work Air conditioners employ the same operating principles and basic components as refrigerators. Refrigerators use energy (usually electricity) to transfer heat from the cool interior of the refrigerator to the relatively warm surroundings; likewise, an air conditioner uses energy to transfer heat from the interior space to the relatively warm outside environment. An air conditioner uses a cold indoor coil called the evaporator. The condenser, a hot outdoor coil, releases the collected heat outside. The evaporator and condenser coils are serpentine tubing surrounded by aluminum fins. This tubing is usually made of copper.

190

Homeowner's Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet), Building America Case Study: Technology Solutions for Existing Homes, Building Technologies Office (BTO)  

SciTech Connect

This fact sheet offers a step-by-step guide to proper installation of window air conditioning units, in order to improve efficiency and comfort for homeowners.

2013-06-01T23:59:59.000Z

191

Unified power quality conditioner for grid integration of wind generators.  

E-Print Network (OSTI)

?? A Unified Power Quality Conditioner (UPQC) is relatively a new member of the custom power device family. It is a comprehensive custom power device, (more)

Ganesh, Jayanti Navilgone, (Thesis)

2008-01-01T23:59:59.000Z

192

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air  

NLE Websites -- All DOE Office Websites (Extended Search)

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners Title Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners Publication Type Report LBNL Report Number LBNL-63204 Year of Publication 2007 Authors McNeil, Michael A., and Maithili Iyer Date Published 03/2007 Keywords India Air Conditioner Efficiency Standards Abstract The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency.

193

Horizontal coring using air as the circulating fluid: Some prototype studies conducted in G Tunnel at the Nevada Test Site for the Yucca Mountain Project  

SciTech Connect

Horizontal coring using air as the circulating fluid has been conducted in the G Tunnel Underground Facility (GTUF) at the Nevada Test Site. This work is part of the prototype investigations of hydrogeology for the Yucca Mountain Project. The work is being conducted to develop methods and procedures that will be used at the Department of Energy`s Yucca Mountain Site, a candidate site for the nation`s first high-level nuclear waste repository, during the site characterization phase of the investigations. The United States Geological Survey (USGS) is conducting this prototype testing under the guidance of the Los Alamos National Laboratory (LANL) and in conjunction with Reynolds Electrical & Engineering Company (REECo), the drilling contractor. 7 refs., 8 figs., 5 tabs.

Chornack, M.P. [Geological Survey, Las Vegas, NV (USA); French, C.A. [Reynolds Electrical and Engineering Co., Inc., Las Vegas, NV (USA)

1989-12-31T23:59:59.000Z

194

NREL: Technology Transfer - NREL Tests Advanced Air Conditioner ...  

The Coolerado H-80 easily surpassed the challenge's objective of exceeding DOE 2010 efficiency standards by 40%.

195

DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS  

E-Print Network (OSTI)

the Annual DOE Active Solar Heating and Cooling Contractors'and Annual DOE Active Solar Heating and Cooling Contractors'refrigeration systems for solar active heating and cooling

Dao, K.

2013-01-01T23:59:59.000Z

196

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network (OSTI)

of Energy, DRAFT Marginal Energy Prices Report, July, 1999.energy use by the energy price paid by the household.energy consumption, energy price, discount rate, and central

Rosenquist, G.

2010-01-01T23:59:59.000Z

197

Variable Speed Fan Retrofits for Computer Room Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE))

Case study describes various concepts for more cost-effective cooling solutions in data centers, while keeping in mind that the reliability of computing systems and their respective cooling systems is always a key criterion.

198

DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS  

E-Print Network (OSTI)

of the University of California, nor any of their employees,of the University of California. The views and opinions ofof the University of California. DEVELOPMENT OF SOLAR DRIVEN

Dao, K.

2013-01-01T23:59:59.000Z

199

Building Technologies Office: Central Air Conditioner and Heat...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Use to Save Money. Learn More. News DOE Issues Notice of Proposed Rulemaking for Commercial Refrigeration Equipment Energy Conservation Standard August 29, 2013 DOE Issues...

200

NREL Solves Residential Window Air Conditioner Performance Limitations (Fact Sheet)  

SciTech Connect

Comprehensive performance tests lead to enhanced modeling capability and affordable methods to increase energy efficiency.

Not Available

2013-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Measuring Short-term Air Conditioner Demand Reductions for Operations...  

NLE Websites -- All DOE Office Websites (Extended Search)

frequently without affecting customer comfort. A key issue for grid operations and electricity market settlement is how to accurately measure shorter-term (e.g., ten's of...

202

Laboratory Performance Testing of Residential Window Mounted Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was delivered at the U.S. Department of Energy Building America Technical Update meeting on April 29-30, 2013, in Denver, Colorado.

203

Distribution substation load impacts of residential air conditioner load control  

SciTech Connect

An ongoing experiment to monitor the substation level load impacts of end-use load control is described. An overview of the data acquisition system, experimental procedures and analysis techniques are provided. Results of the 1983 and 1984 experiments demonstrate the value of aggregate load impact monitoring as a means of verifying load research results, calculating the diversity of end-use loads, and predicting the impacts of load management on the transmission and distribution systems.

Heffner, G.C.; Kaufman, D.A.

1985-07-01T23:59:59.000Z

204

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network (OSTI)

Richland, WA. Report No. PNNL- 7. U.S. Department of Energy,National Laboratory (PNNL) using the Building Loads andADL), and David Winiarski (PNNL). This work was supported by

Rosenquist, G.

2010-01-01T23:59:59.000Z

205

YMGI Through-the-Wall Air Conditioner Determined Noncompliant...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

testing revealed that this model operates at a Seasonal Energy Efficiency Rating (SEER) of 8.3. The current federal standard requires that through-the-wall split system...

206

Fault Detection and Diagnosis for Air-Conditioners and Heat ...  

Science Conference Proceedings (OSTI)

... Calculation of the energetic metric will include weather data to weight the ... and rooftop units and will promote market implementation of FDD tools. ...

2012-12-17T23:59:59.000Z

207

Air Conditioner Efficiency Under Hot Dry and Hot Humid Conditions  

Science Conference Proceedings (OSTI)

The seasonal energy efficiency ratio (or SEER) has been the subject of extensive research, development, use, and revision for over 30 years. This report gives a review of the past, present, and future of SEER. This review is needed to provide a common background and perspective in response to a move away from one national standard to three standards. Recommendations are made for what electric utilities can do in response to the challenges and opportunities presented by regional climate-sensitive SEERs.

2008-06-23T23:59:59.000Z

208

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network (OSTI)

for major household appliances. Any new or amended standardcosts), lifetime of the appliance, and a discount rate. LCCconsumers use in purchasing appliances. Consumers purchase

Rosenquist, G.

2010-01-01T23:59:59.000Z

209

Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)  

SciTech Connect

This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

Kozubal, E.

2013-02-01T23:59:59.000Z

210

Automobile air-conditioning unit. Final report  

SciTech Connect

In this study the refrigerant in the automobile air-conditioner is compressed by thermal energy in a unique compression system rather than by work in a standard compressor. The compression uses an intermittent compression process with a solid absorbent. The vapor is absorbed by an absorbent at relatively low temperature and ejected as the absorbent temperature is raised. A set of one way valves limits flow to one direction. Major contributions are heat transfer requirements, molecular sieve-refrigerant matching, minimizing non-producing mass, solving thermal fatigue and shock problems, and applying this to automobile air-conditioning. The performance study shows energy savings up to fifty percent are possible, depending on engine load. A twenty percent energy savings with the vehicle tested with the air-conditioner in operation is average. The study also showed that less fuel is used with the windows open than with the air-conditioner operating.

Schaetzle, W.J.

1982-12-01T23:59:59.000Z

211

Troubleshooting the residential air conditioning system  

Science Conference Proceedings (OSTI)

In order to effectively diagnose problems in a residential air conditioning system, the technician should develop and follow a logical step-by-step troubleshooting procedure. A list of problems, along with possible causes and solutions, that a technician may encounter when servicing a residential air conditioner is presented.

Puzio, H. [Sussex County Vocational Technical School, Sparta, NJ (United States)

1996-01-01T23:59:59.000Z

212

DOE Requires Air-Con International to Cease Sales of Inefficient Air  

NLE Websites -- All DOE Office Websites (Extended Search)

Requires Air-Con International to Cease Sales of Inefficient Requires Air-Con International to Cease Sales of Inefficient Air Conditioners and Proposes Penalties DOE Requires Air-Con International to Cease Sales of Inefficient Air Conditioners and Proposes Penalties September 21, 2010 - 6:43pm Addthis The Department has issued a Notice of Noncompliance Determination and Proposed Civil Penalty to Air-Con, International, requiring Air-Con to cease the sale of certain air-conditioning systems in the United States and proposing a civil penalty of $231,090 for sales of these products in violation of the applicable energy efficiency standards. This action reflects the Department's continued commitment to act aggressively to remove unlawful products from the market. In March, 2010, the Department issued a subpoena requiring Air-Con to

213

Stronger Manufacturers' Energy Efficiency Standards for Residential Air  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Stronger Manufacturers' Energy Efficiency Standards for Residential Stronger Manufacturers' Energy Efficiency Standards for Residential Air Conditioners Go Into Effect Today Stronger Manufacturers' Energy Efficiency Standards for Residential Air Conditioners Go Into Effect Today January 23, 2006 - 11:09am Addthis WASHINGTON, DC -- To increase the energy efficiency of residential air conditioners, the U.S. Department of Energy (DOE) has issued new manufacturing standards that go into effect today, January 23, 2006, for products manufactured in, or imported into, the United States. "Homeowners who choose to buy more energy-efficient air conditioning systems after today will realize significant savings in their energy bills and greatly reduce their energy use," said Secretary of Energy Samuel W. Bodman. "These new energy efficiency standards are the first of several

214

Variability of the Thermohaline Circulation in an Ocean General Circulation Model Coupled to an Atmospheric Energy Balance Model  

Science Conference Proceedings (OSTI)

The variability of the oceans thermohaline circulation in an oceanic general circulation model (OGCM) coupled to a two-dimensional atmospheric energy balance model (EBM) is examined. The EBM calculates air temperatures by balancing heat fluxes, ...

David W. Pierce; K-Y. Kim; Tim P. Barnett

1996-05-01T23:59:59.000Z

215

BEETIT: Building Cooling and Air Conditioning  

Science Conference Proceedings (OSTI)

BEETIT Project: The 14 projects that comprise ARPA-Es BEETIT Project, short for Building Energy Efficiency Through Innovative Thermodevices, are developing new approaches and technologies for building cooling equipment and air conditioners. These projects aim to drastically improve building energy efficiency and reduce greenhouse gas emissions such as carbon dioxide (CO2) at a cost comparable to current technologies.

None

2010-09-01T23:59:59.000Z

216

Simulations of Mesoscale Circulations in the Center of the Iberian Peninsula for Thermal Low Pressure Conditions. Part II: Air-Parcel Transport Patterns  

Science Conference Proceedings (OSTI)

This paper discusses the variability of air-parcel transport under similar summer thermal low pressure conditions over the Iberian Peninsula. Three-dimensional trajectories were estimated by means of the Topography Vorticity-Mode Mesoscale model. ...

Fernando Martn; Magdalena Palacios; Sylvia N. Cresp

2001-05-01T23:59:59.000Z

217

Large-Scale Vertical and Horizontal Circulation in the North Atlantic Ocean  

Science Conference Proceedings (OSTI)

Observations of large-scale hydrography, airsea forcing, and regional circulation from numerous studies are combined by inverse methods to determine the basin-scale circulation, average diapycnal mixing, and adjustments to airsea forcing of the ...

Rick Lumpkin; Kevin Speer

2003-09-01T23:59:59.000Z

218

Residential Humidity Control: Exciting New Opportunities with Air Flow Modulation  

E-Print Network (OSTI)

This paper reviews psychrometric principles and shows how to formulate a psychrometric chart from a single equation. The chart is used to demonstrate the manner in which a conventional single-speed air conditioner adjusts its operating point in an attempt to control humidity over a range of conditions. The system performance with an electronically commutated motor (ECM) driving the blower is then presented. With ECM blower speed control, it is possible to raise the sensible capacity, reduce the sensible capacity, and boost the efficiency of an otherwise conventional air conditioner. This makes such systems ideal to respond to the changing loads in a hot and humid climate.

Crawford, J. G.

1987-01-01T23:59:59.000Z

219

Residential Energy Efficiency Tax Credit (Federal) | Open Energy...  

Open Energy Info (EERE)

Central Air conditioners, Doors, Furnaces, Heat pumps, Roofs, Water Heaters, Windows, Biomass, Circulating fans used in a qualifying furnace, Stoves that use qualified...

220

Air-Con Agrees to Pay Civil Penalty to Resolve Enforcement Action |  

NLE Websites -- All DOE Office Websites (Extended Search)

Air-Con Agrees to Pay Civil Penalty to Resolve Enforcement Action Air-Con Agrees to Pay Civil Penalty to Resolve Enforcement Action Air-Con Agrees to Pay Civil Penalty to Resolve Enforcement Action November 23, 2010 - 6:34pm Addthis The Department of Energy has settled the civil penalty action it initiated against Air-Con International for Air-Con's sale of air conditioners in the United States that used more energy than allowed by federal law. On September 20, 2010, based on Air-Con's responses to a DOE subpoena, DOE ordered Air-Con to stop selling noncompliant air conditioners in the United States and proposed civil penalties for the noncompliant units sold by the company. Air-Con promptly ceased U.S. sales of the noncompliant models. In the settlement announced today, DOE agreed to accept a civil penalty of $10,000, after considering factors set forth in DOE's penalty guidance,

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Air-Con Agrees to Pay Civil Penalty to Resolve Enforcement Action |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air-Con Agrees to Pay Civil Penalty to Resolve Enforcement Action Air-Con Agrees to Pay Civil Penalty to Resolve Enforcement Action Air-Con Agrees to Pay Civil Penalty to Resolve Enforcement Action November 23, 2010 - 6:34pm Addthis The Department of Energy has settled the civil penalty action it initiated against Air-Con International for Air-Con's sale of air conditioners in the United States that used more energy than allowed by federal law. On September 20, 2010, based on Air-Con's responses to a DOE subpoena, DOE ordered Air-Con to stop selling noncompliant air conditioners in the United States and proposed civil penalties for the noncompliant units sold by the company. Air-Con promptly ceased U.S. sales of the noncompliant models. In the settlement announced today, DOE agreed to accept a civil penalty of $10,000, after considering factors set forth in DOE's penalty guidance,

222

Demonstration and Testing of ClimaStat for Improved Rooftop Air-Conditioning Efficeincy  

NLE Websites -- All DOE Office Websites (Extended Search)

Demonstration and Testing of ClimaStat® for Improved Rooftop Air-Conditioning Efficiency Presented at IA Technology Deployment Working Group Meeting March 15, 2012 By Dan Howett, PE Oak Ridge National Laboratory Demonstration/Testing of ClimaStat ® for Improved Efficiency of RTU Air Conditioners * Technology from Advantek Consulting - Patented by Dr. Michael West in 2003. (US Patent #6427454) - Originally demonstrated under DOE's Inventions & Innovations program. * Current demonstration sponsored by DOD's ESTCP program * Uses off-the-shelf components to either... - Modify existing packaged air conditioners, or - Incorporate changes into new RTU equipment before installation * Initial tests show 15% improvement in HVAC efficiency.

223

Demonstration and Testing of ClimaStat for Improved Rooftop Air-Conditioning Efficeincy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Demonstration and Testing of ClimaStat® for Improved Rooftop Air-Conditioning Efficiency Presented at IA Technology Deployment Working Group Meeting March 15, 2012 By Dan Howett, PE Oak Ridge National Laboratory Demonstration/Testing of ClimaStat ® for Improved Efficiency of RTU Air Conditioners * Technology from Advantek Consulting - Patented by Dr. Michael West in 2003. (US Patent #6427454) - Originally demonstrated under DOE's Inventions & Innovations program. * Current demonstration sponsored by DOD's ESTCP program * Uses off-the-shelf components to either... - Modify existing packaged air conditioners, or - Incorporate changes into new RTU equipment before installation * Initial tests show 15% improvement in HVAC efficiency.

224

Tips: Air Ducts | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Ducts Air Ducts Tips: Air Ducts June 24, 2013 - 7:23pm Addthis Air Ducts: Out of Sight, Out of Mind. The unsealed ducts in your attic and crawlspaces lose air, and uninsulated ducts lose heat -- wasting energy and money. Air Ducts: Out of Sight, Out of Mind. The unsealed ducts in your attic and crawlspaces lose air, and uninsulated ducts lose heat -- wasting energy and money. Your air ducts are one of the most important systems in your home, and if the ducts are poorly sealed or insulated they are likely contributing to higher energy bills. Your home's duct system is a branching network of tubes in the walls, floors, and ceilings; it carries the air from your home's furnace and central air conditioner to each room. Ducts are made of sheet metal, fiberglass, or other materials.

225

TEE-0062 - In the Matter of United CoolAir Corp. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

TEE-0062 - In the Matter of United CoolAir Corp. TEE-0062 - In the Matter of United CoolAir Corp. TEE-0062 - In the Matter of United CoolAir Corp. This Decision and Order considers an Application for Exception filed by United CoolAir Corporation (United CoolAir) seeking exception relief from the provisions of 10 C.F.R. Part 431, Subpart F, Energy Conservation Program for Certain Commercial and Industrial Equipment: Commercial Air Conditioners and Heat Pumps Energy Conservation Standards (Commercial Air Conditioner Standards).1 In its Application, United CoolAir asserts that the firm would suffer serious hardship, inequity, or unfair distribution of burdens if required to comply with the 13 SEER energy efficiency standard effective January 1, 2010, 10 C.F.R. § 431.97(b). If United CoolAir's Application for Exception were granted, the firm would

226

TEE-0062 - In the Matter of United CoolAir Corp. | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2 - In the Matter of United CoolAir Corp. 2 - In the Matter of United CoolAir Corp. TEE-0062 - In the Matter of United CoolAir Corp. This Decision and Order considers an Application for Exception filed by United CoolAir Corporation (United CoolAir) seeking exception relief from the provisions of 10 C.F.R. Part 431, Subpart F, Energy Conservation Program for Certain Commercial and Industrial Equipment: Commercial Air Conditioners and Heat Pumps Energy Conservation Standards (Commercial Air Conditioner Standards).1 In its Application, United CoolAir asserts that the firm would suffer serious hardship, inequity, or unfair distribution of burdens if required to comply with the 13 SEER energy efficiency standard effective January 1, 2010, 10 C.F.R. § 431.97(b). If United CoolAir's Application for Exception were granted, the firm would

227

Flow conditioner for fuel injector for combustor and method for low-NO.sub.x combustor  

Science Conference Proceedings (OSTI)

An injector for a gas turbine combustor including a catalyst coated surface forming a passage for feed gas flow and a channel for oxidant gas flow establishing an axial gas flow through a flow conditioner disposed at least partially within an inner wall of the injector. The flow conditioner includes a length with an interior passage opening into upstream and downstream ends for passage of the axial gas flow. An interior diameter of the interior passage smoothly reduces and then increases from upstream to downstream ends.

Dutta, Partha; Smith, Kenneth O.; Ritz, Frank J.

2013-09-10T23:59:59.000Z

228

Laboratory Testing of the Heating Capacity of Air-Source Heat Pumps at Low Outdoor Temperature Conditions  

Science Conference Proceedings (OSTI)

Air-source heat pump systems offer an alternative to the common heating, ventilating, and air conditioning (HVAC) configuration of single split unitary air conditioners with gas heating. In simple terms, heat pumps are traditional air conditioning units with the added capability of running in reverse as required by the building load. Thus, where the traditional air conditioning unit has an indoor evaporator to remove heat from the space and an outdoor condenser to reject heat to the ambient environment, ...

2010-12-22T23:59:59.000Z

229

The Summertime Heat Budget and Circulation of Southeast New England Shelf Waters  

Science Conference Proceedings (OSTI)

A modeling study of summer ocean circulation on the inner shelf south of Cape Cod, Massachusetts, has been conducted. The influences of winds, airsea heat fluxes, tides, and shelfwide circulation are all incorporated. The model reproduces ...

John L. Wilkin

2006-11-01T23:59:59.000Z

230

A review of polymer-based water conditioners for reduction of handling-related injury  

Science Conference Proceedings (OSTI)

Fish are coated with an external layer of protective mucus. This layer serves as the primary barrier against infection or injury, reduces friction, and plays a role in ionic and osmotic regulation. However, the mucus layer is easily disturbed when fish are netted, handled, transported, stressed, or subjected to adverse water conditions. Water additives containing polyvinylpyrrolidone (PVP) or proprietary polymers have been used to prevent the deleterious effects of mucus layer disturbances in the commercial tropical fish industry, aquaculture, and for other fisheries management purposes. This paper reviews research on the effectiveness of water conditioners, and examines the contents and uses of a wide variety of commercially available water conditioners. Water conditioners containing polymers may reduce external damage to fish held in containers during scientific experimentation, including surgical implantation of electronic tags. However, there is a need to empirically test the effectiveness of water conditioners at preventing damage to and promoting healing of the mucus layer. A research agenda is provided to advance the science related to the use of water conditions to improve the condition of fish during handling and tagging.

Harnish, Ryan A.; Colotelo, Alison HA; Brown, Richard S.

2011-01-01T23:59:59.000Z

231

Room Air Conditioning Energy Efficiency and Demand Response Potential  

Science Conference Proceedings (OSTI)

Room or window air conditioners are a common appliance in parts of the United States residential sector for providing summertime cooling. The technology is based on the same vapor compression cycle common in central air conditioning and refrigeration applications, but with all system components in one enclosure, which is generally small and comparatively inexpensive. The systems are simple and modular enough to be installed by the homeowner, and can be installed in windows without major modification, or ...

2011-06-30T23:59:59.000Z

232

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network (OSTI)

water heater replacement, air conditioner replacement, solarwater heater replacement, air conditioner replacement, solar

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

233

General Circulation Statistics on Short Time Scales  

Science Conference Proceedings (OSTI)

The sensitivity of various zonal mean general circulation statistics to the choice of the averaging period used to define them is tested with upper-air data for the Northern Hemisphere taken from the NMC global analysis for the winter of 197677. ...

Richard D. Rosen; David A. Salstein

1982-07-01T23:59:59.000Z

234

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

the current cost of production of 3.5 Rs per kWh. It isthe average cost of production to be 3.50 Rs. per kWh, or $the cost of production significantly at 4.80 Rs. per kWh. As

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

235

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

L ABORATORY China Energy Efficiency Round Robin TestingNeed to Improve the Energy Efficiency of Energy Consumingfor Implementing the China Energy Efficiency Label System (

Zhou, Nan

2010-01-01T23:59:59.000Z

236

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

E-Print Network (OSTI)

In other words, we had the answer key and could grade whichwere simulated, the answer key was available and we could

Bode, Josh

2013-01-01T23:59:59.000Z

237

Variable Refrigerant Flow Air Conditioners and Heat Pumps for Commercial Buildings  

Science Conference Proceedings (OSTI)

Multi-split heat pumps have evolved from a technology suitable for residential and light commercial buildings to variable refrigerant flow (VRF) systems that can provide efficient space conditioning for large commercial buildings. VRF systems are enhanced versions of ductless multi-split systems, permitting more indoor units to be connected to each outdoor unit and providing additional features such as simultaneous heating and cooling and heat recovery. VRF systems are very popular in Asia and Europe and...

2008-01-25T23:59:59.000Z

238

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network (OSTI)

18 2.3.1 Electricity Price19 2.3.2 Electricity PriceELECTRICITY PRICES . . . . . . . . . . . . . . . . . . . 37

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

239

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network (OSTI)

37 RESULTS USING TARIFF-BASED ELECTRICITYHourly-based Electricity Price Models Tariff-based HourlyRESULTS USING TARIFF-BASED ELECTRICITY PRICES LCC Results

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

240

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

noted that reform of electricity tariff structures is a longin the residential electricity tariff structures. Each ofcosts, and prevailing electricity tariffs may have changed.

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

E-Print Network (OSTI)

2004. Working Group 2 Demand Response Program Evaluation A. Barat, D. Watson. 2007. Demand Response Spinning Reserveand E. Parker (2009). Demand Response Spinning Reserve

Bode, Josh

2013-01-01T23:59:59.000Z

242

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

E-Print Network (OSTI)

and Industrial Facilities to Dynamic Electricity Prices.and Industrial Facilities to Dynamic Electricity Prices.

Bode, Josh

2013-01-01T23:59:59.000Z

243

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

average. Rates collected by most State Electricity Boards inState Electricity Boards and Electricity Departments 2002- Discount Rates

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

244

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

because of the higher electricity rates, higher hours ofin use patterns and electricity rates between commercial andUEC), marginal electricity rates, and discount rates.

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

245

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network (OSTI)

2030. Estimating future electricity rates is very difficult,payback, the required electricity rate is only for the yearcase, the year 2008. The electricity rate used in the PBP

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

246

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

Electricity Prices Residential electricity rates are muchrates in India. Residential electricity rates are subsidizedand electricity rates between commercial and residential

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

247

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

Table 5 Cost-Effectiveness of Energy Efficiency Commercial6 Cost-Effectiveness of Energy Efficiency ResidentialTable 5 Cost-Effectiveness of Energy Efficiency Commercial

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

248

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

E-Print Network (OSTI)

017F.PDF KEMA, Inc. 2011. PJM Empirical Analysis of DemandMethods. Prepared for the PJM Markets Implementation~/media/markets-ops/dsr/pjm-analysis-of-dr-baseline-methods-

Bode, Josh

2013-01-01T23:59:59.000Z

249

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network (OSTI)

Energy Regulatory Commission (FERC) Form 1 filings. http://Energy Regulatory Commission (FERC) website through Form 714annual data submitted to FERC from regulated utilities and

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

250

Technical and economic analysis of energy efficiency of Chinese room air conditioners  

E-Print Network (OSTI)

the impact on national energy consumption by adoption of thecase forecast of national energy consumption assumes thatcase forecast of national energy consumption assumes the

Fridley, David G.; Rosenquist, Gregory; Jiang, Lin; Li, Aixian; Xin, Dingguo; Cheng, Jianhong

2001-01-01T23:59:59.000Z

251

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

costs is adequately compensated by lower electricity bills.Electricity bill savings are in turn dependent on the hoursmargin, residential electricity bills do not cover utility

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

252

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

labeling program (Energy Guide). In order to ensure thethe yellow label titled Energy Guide and has clearly sti-

Zhou, Nan

2010-01-01T23:59:59.000Z

253

Ground Source Heat Pump Air Conditioner Monitoring Control System Design Based on CAN Bus  

Science Conference Proceedings (OSTI)

Based on CAN bus technology, chooses ST's ARM Cortex-M3 core, new generation STM32 embedded enhanced processor STM32F103 as main control chip, designs the overall structure of system, CAN functional block diagram, CAN communication software and so on. ... Keywords: CAN bus embedded STM32F103

Tong Gang; Li Ping

2010-06-01T23:59:59.000Z

254

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

the market trend is increasingly towards energy efficiency.trend of trans- formation to an energy-efficient products market.

Zhou, Nan

2010-01-01T23:59:59.000Z

255

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network (OSTI)

energy expenses based upon electricity prices that customers may pay if electricity markets become deregulated. Electricity price trends:

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

256

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

where the static pressure (ESP) is measured. The length oftaps used to measure the ESP may be in the same duct or inand the measurement of the ESP is performed in 4 points at

Zhou, Nan

2010-01-01T23:59:59.000Z

257

The biogeochemistry and residual mean circulation of the southern ocean  

E-Print Network (OSTI)

I develop conceptual models of the biogeochemistry and physical circulation of the Southern Ocean in order to study the air-sea fluxes of trace gases and biological productivity and their potential changes over ...

Ito, Takamitsu, 1976-

2005-01-01T23:59:59.000Z

258

A Hybrid Coupled General Circulation Model for El Nio Studies  

Science Conference Proceedings (OSTI)

A model is developed for tropical airsea interaction studies, which is intermediate in complexity between the large coupled general circulation models (coupled GCMs) coming into use and the simple two-level models with which pioneering El Nio...

J. David Neelin

1990-03-01T23:59:59.000Z

259

Commissioning Tools for Heating/Cooling System in Residence - Verification of Floor Heating System and Room Air Conditioning System Performance  

E-Print Network (OSTI)

Tools of evaluating the performance of floor heating and room air conditioner are examined as a commissioning tool. Simple method is needed to check these performance while in use by residents, because evaluation currently requires significant time and effort. Therefore, this paper proposes a) two methods of evaluating the floor heating efficiency from the room / crawl space temperature and the energy consumption and b) method of evaluating COP of the room air conditioner from the data measured at the external unit. Case studies in which these tools were applied to actual residences are presented to demonstrate their effectiveness.

Miura, H.; Hokoi, S.; Iwamae, A.; Umeno, T.; Kondo, S.

2004-01-01T23:59:59.000Z

260

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Desiccant Enhanced Evaporative Air Conditioning Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning May 29, 2012 - 5:22pm Addthis This breakthrough combines desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90 percent less electricity and up to 80 percent less total energy than traditional air conditioning. This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings. View the entire Lab Breakthrough playlist. What are the key facts? Recent materials advances and liquid desiccant advances to design the compact and cost-effective DEVAP system. DEVAP uses 90 percent less electricity and up to 80 percent less

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning May 29, 2012 - 5:22pm Addthis This breakthrough combines desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90 percent less electricity and up to 80 percent less total energy than traditional air conditioning. This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings. View the entire Lab Breakthrough playlist. What are the key facts? Recent materials advances and liquid desiccant advances to design the compact and cost-effective DEVAP system.

262

A smart GUI based air-conditioning and lighting controller for energy saving in building  

Science Conference Proceedings (OSTI)

This paper will concentrate on the algorithm and control strategies where the air-conditioners and lighting system can be controlled using microcontroller; a microcontroller is chosen due to its low cost and high flexibility. Conceptually, the controller ... Keywords: energy saving control system, graphic LCD, graphical user interface (GUI), microcontroller

M. F. Abas; N. MD. Saad; N. L. Ramli

2009-12-01T23:59:59.000Z

263

A thermal comfort levels investigation of a naturally ventilated and air-conditioned office  

Science Conference Proceedings (OSTI)

The purpose of this study is to investigate thermal comfort levels of a naturally ventilated and air-conditioner office. Field experiments conducted in an office room in Universiti Putra Malaysia (UPM) used survey questionnaires and physical measurements. ... Keywords: PMV, mechanically ventilation, naturally ventilated, neutral temperature, objective study, subjective approach, thermal comfort

R. Daghigh; N. M. Adam; K. Sopian; A. Zaharim; B. B. Sahari

2008-09-01T23:59:59.000Z

264

Technology Assessment and Application Guide for an Active Voltage Conditioner with Storage Option (AVC-Store)  

Science Conference Proceedings (OSTI)

This report describes and documents the construction, performance, and application of an active voltage conditioner (AVC) with energy storage. The system8211called the AVC-Store8211is manufactured by Vectek in Napier, New Zealand. Composed of a novel power electronics module, the system is organized to mitigate voltage sags, phase shift, and outages. This report describes the various subsystems within the AVC-Store, its operation, results of characterization tests, and issues related to its application a...

2006-06-27T23:59:59.000Z

265

Candidate chemical systems for air cooled solar powered, absorption air conditioner design. Part I. Organic absorbent systems  

DOE Green Energy (OSTI)

All the available experimental evidence suggests that the optimum ''organic'' absorbent/refrigerant combination would be a methane derivative with a single hydrogen atom with chlorine and fluorine atoms in the other sites, as refrigerant. This would be hydrogen bonded to an absorbent molecule containing the group =NC/sup -/O, with the substituent groups being such that no steric hindrance took place. Cycle analyses showed that the ratio of internal heat transfer to cooling would be large, probably impractically so in view of the high coefficient of performance needed for solar driven cooling and the additional handicap of heat rejection to the atmosphere. A more promising approach would be to reduce the internal heat transfer per unit of space cooling by selecting a refrigerant with a high latent heat of vaporization and selecting an absorbent with suitable properties.

Biermann, W.J.

266

Candidate chemical systems for air cooled, solar powered, absorption air conditioner design. Part II. Solid absorbents, high latent heat refrigerants  

DOE Green Energy (OSTI)

Work done in attempting to qualify absorption refrigeration systems based on refrigerants with intermediate latent heats of vaporization is summarized. In practice, these comprise methanol, ammonia, and methylamine. A wide variety of organic substances, salts, and mixtures were evaluated in as systematic a manner as possible. Several systems of interest are described. The system, LiClO/sub 3/--LiBr--H/sub 2/O, is a good back up system to our first choice of an antifreeze additive system, and thermodynamically promising but subject to some inconvenient materials limitations. The system, LiBr/ZnBr/sub 2/--methanol, is thermodynamically promising but requires additional kinetic qualification. Chemical stability of the system, LiCNS--ammonia/methylamine with various other third components, does not appear to be adequate for a long-lived system.

Biermann, W. J.

1978-04-01T23:59:59.000Z

267

Anomaly General Circulation Models  

Science Conference Proceedings (OSTI)

Anomally models based on a spectral general circulation model (GCM) are formulated and applied to study of low-frequency atmospheric variability in the extratropics, and long-range forecasting research. A steady linear version of the anomaly ...

A. Navarra; K. Miyakoda

1988-05-01T23:59:59.000Z

268

Reducing air conditioning waste by signalling it is cool outside  

SciTech Connect

This experiment looked at the effects on residential energy consumption of providing homeowners with (1) a signalling device that indicated a conservation opportunity and (2) information feedback about their rate of energy use. The signalling device operated when the outside temperature was below 68F and the air conditioner was on. Homeowners were told that the signalling device indicated when they could cool their house effectively by opening the windows and turning off their air conditioner. Forty households were randomly assigned to one of four conditions: signalling device only, feedback only, both, neither. The results showed a significant 15.7% decrease in energy use for those households with the signalling devices. Neither the feedback nor interaction effect was significant. The advantages and disadvantages of having people in the control cycle were discussed. 4 references, 1 table.

Becker, L.J.; Seligman, C.

1978-07-01T23:59:59.000Z

269

Computer controlled air conditioning systems  

SciTech Connect

This patent describes an improvement in a computer controlled air conditioning system providing for circulation of air through an air conditioned house in contact with concrete walls requiring a humidity within a critical range. The improvement consists of: a computer for processing sensed environmental input data including humidity and oxygen to produce output control signals for affecting the humidity of the air in the house; provision for an air flow circulation path through the house in contact with the concrete walls; sensing responsive to the amount of oxygen in the house for providing input signals to the computer; mixing for combining with the air in the house a variable amount of fresh atmospheric air to supply fresh oxygen; and humidity modifying means for modifying the humidity of the air flowing in the flow path responsive to the control signals.

Dumbeck, R.F.

1986-02-04T23:59:59.000Z

270

Seasonal Energy Efficiency Ratio (SEER) Investigation for Residential and Small Commercial Air-Source Heat Pumps  

Science Conference Proceedings (OSTI)

Electric utilities frequently use the seasonal energy efficiency ratio (SEER) in air conditioningbased incentive programs to categorize energy efficiency and to quantify financial value. For residential and small commercial unitary air conditioners and heat pumps, SEER is determined by the procedures outlined in ANSI/AHRI Standard 210/240. Within Standard 210/240, SEER is calculated based on laboratory test results and equations that follow specific assumptions regarding indoor temperature, ...

2012-12-21T23:59:59.000Z

271

Analysis of historical residential air-conditioning equipment sizing using monitored data  

SciTech Connect

Monitored data were analyzed to determine whether residential air conditioners in the Pacific Northwest historically have been sized properly to meet or slightly exceed actual cooling requirements. Oversizing air-conditioning equipment results in a loss of efficiency because of increased cycling and also lowers humidity control. On the other hand, the penalty of undersizing air-conditioning equipment may be some loss of comfort during extremely hot weather. The monitored data consist of hourly space-conditioning electrical energy use and internal air temperature data collected during the past 7 years from 75 residences in the Pacific Northwest. These residences are equipped with central air conditioners or heat pumps. The periods with the highest cooling energy use were analyzed for each site. A standard industry sizing methodology was used for each site to determine a sizing estimate. Both the sizing recommendation based on Manual J and peak monitored loads are compared to the capacity of the installed equipment for each site to study how the actual capacity differed from both the estimate of proper sizing and from actual demands. Characteristics of the maximum cooling loads are analyzed here to determine which conditions put the highest demand on the air conditioner. Specifically, internal air temperature data are used to determine when the highest cooling loads occur, at constant thermostat settings or when the thermostat was set down. This analysis of monitored data also provides insight into the extent that occupant comfort may be affected by undersizing air conditioners. The findings of this research indicate that cooling equipment historically has often but not always been oversized beyond industry-recommended levels. However, some occupants in homes with undersized, properly sized, and, in rare occasions, even oversized cooling equipment appear to suffer because the cooling equipment cannot always provide adequate cooling. Key findings are summarized.

Lucas, R.G.

1993-02-01T23:59:59.000Z

272

A Field Study on Residential Air Conditioning Peak Loads During Summer in College Station, Texas  

E-Print Network (OSTI)

Severe capacity problems are experienced by electric utilities during hot summer afternoons. Several studies have found that, in large part, electric peak loads can be attributed to residential airconditioning use. This air-conditioning peak depends primarily on two factors: (i) the manner in which the homeowner operates his air-conditioner during the hot summer afternoons, and (ii) the amount by which the air-conditioner has been over-designed. Whole-house and air-conditioner electricity use data at 15 minute time intervals have been gathered and analyzed for 8 residences during the summer of 1991, six of which had passed the College Station Good Cents tests. Indoor air temperatures were measured by a mechanical chart recorder, while a weather station located on the main campus of Texas A&M university provided the necessary climatic data, especially ambient temperature, relative humidity and solar radiation. The data were analysed to determine the extent to which air-conditioning over-sizing and homeowner intervention contributes to peak electricity use for newer houses in College Station, Texas.

Reddy, T. A.; Vaidya, S.; Griffith, L.; Bhattacharyya, S.; Claridge, D. E.

1992-01-01T23:59:59.000Z

273

Research on Thermal Properties in a Phase Change Wallboard Room Based on Air Conditioning Cold Storage  

E-Print Network (OSTI)

After comparing the thermal performance parameters of an ordinary wall room to a phase change wall (PCW) room, we learn that phase change wallboard affects the fluctuation of temperature in air-conditioning room in the summer. We built a PCW room and an ordinary wall room, which are cooled by an air-conditioner. We used differential scanning calorimetry (DSC) to test the temperature field and heat flow fluctuation in these rooms. Through analyzing the data tested, we found that the mean temperature of PCW is lower than that of ordinary wall room by 1 to 2?, and PCW can lower the heat flow by 4.6W/m2. Combining phase change material with the building envelope can lower the indoor temperature, make the room thermally comfortable, and cut down the turn-on-and-off frequency of the air-conditioner and the primary investment and operating costs. It alleviates the urgent need for electricity.

Feng, G.; Li, W.; Chen, X.

2006-01-01T23:59:59.000Z

274

Addressing Water Consumption of Evaporative Coolers with Greywater  

E-Print Network (OSTI)

efficiency compared to vapor compression air conditioners,with conventional vapor compression air conditioners.that the efficiency of vapor compression air conditioners

Sahai, Rashmi

2013-01-01T23:59:59.000Z

275

Engineering study - alternatives for SHMS high temperature/moisture gas sample conditioners for the aging waste facility  

SciTech Connect

The Standard Hydrogen Monitoring Systems have been experiencing high temperature/moisture problems with gas samples from the Aging Waste Tanks. These moist hot gas samples have stopped the operation of the SHMS units on tanks AZ-101, AZ-102, and AY-102. This study looks at alternatives for gas sample conditioners for the Aging Waste Facility.

THOMPSON, J.F.

1999-06-02T23:59:59.000Z

276

Improving air handler efficiency in houses  

SciTech Connect

Although furnaces, air conditioners and heat pumps have become significantly more efficient over the last couple of decades, residential air handlers have typical efficiencies of only 10% to 15% due to poor electric motor performance and aerodynamically poor fans and fan housings. Substantial increases in performance could be obtained through improved air handler design and construction. A prototype residential air handler intended to address these issues has recently been developed. The prototype and a standard production fan were tested in a full-scale duct system and test chamber at LBNL specifically designed for testing heating, ventilation, and air conditioning systems. The laboratory tests compared efficiency, total airflow, sensitivity to duct system flow resistance, and the effects of installation in a smaller cabinet. The test results showed that the prototype air handler had about twice the efficiency of the standard air handler (averaged over a wide range of operating conditions) and was less sensitive to duct system flow resistance changes. The performance of both air handlers was significantly reduced by reducing the clearance between the air handler and cabinet it was placed in. These test results showed that in addition to the large scope for performance improvement, air handler fans need to be tested in the cabinets they operate in.

Walker, Iain S.

2004-05-01T23:59:59.000Z

277

Air-Con International: Noncompliance Determination and Proposed Penalty  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Con International: Noncompliance Determination and Proposed Con International: Noncompliance Determination and Proposed Penalty (2010-SE-0301) Air-Con International: Noncompliance Determination and Proposed Penalty (2010-SE-0301) September 20, 2010 DOE issued a Notice of Noncompliance Determination to Air-Con International finding that a variety of central air conditioners and air conditioning heat pumps distributed under the Air-Con private label do not comport with the energy conservation standards. DOE also alleged in a Notice of Proposed Civil Penalty that Air-Con imported and distributed the noncompliant products in the U.S. Federal law subjects manufacturers and private labelers to civil penalties if those parties distribute in the U.S. products that do not meet applicable energy conservation standards. This

278

List of Duct/Air sealing Incentives | Open Energy Information  

Open Energy Info (EERE)

Duct/Air sealing Incentives Duct/Air sealing Incentives Jump to: navigation, search The following contains the list of 580 Duct/Air sealing Incentives. CSV (rows 1-500) CSV (rows 501-580) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP (Central and North) - Residential Energy Efficiency Programs (Texas) Utility Rebate Program Texas Construction Installer/Contractor Multi-Family Residential Building Insulation Caulking/Weather-stripping Comprehensive Measures/Whole Building Custom/Others pending approval Duct/Air sealing Unspecified technologies Yes AEP (Central and SWEPCO) - Coolsaver A/C Tune Up (Texas) Utility Rebate Program Texas Commercial Installer/Contractor Residential Central Air conditioners Custom/Others pending approval Duct/Air sealing

279

AIR COOLED NEUTRONIC REACTOR  

DOE Patents (OSTI)

A nuclear reactor of the air-cooled, graphite moderated type is described. The active core consists of a cubicle mass of graphite, approximately 25 feet in each dimension, having horizontal channels of square cross section extending between two of the opposite faces, a plurality of cylindrical uranium slugs disposed in end to end abutting relationship within said channels providing a space in the channels through which air may be circulated, and a cadmium control rod extending within a channel provided in the moderator. Suitable shielding is provlded around the core, as are also provided a fuel element loading and discharge means, and a means to circulate air through the coolant channels through the fuel charels to cool the reactor.

Fermi, E.; Szilard, L.

1958-05-27T23:59:59.000Z

280

Innovative Evaporative and Thermally Activated Technologies Improve Air Conditioning, The Spectrum of Clean Energy Innovation (Fact Sheet)  

NLE Websites -- All DOE Office Websites (Extended Search)

Innovative Evaporative and Innovative Evaporative and Thermally Activated Technologies Improve Air Conditioning Researchers at the National Renewable Energy Laboratory (NREL) invented a breakthrough technology that improves air conditioning in a novel way-with heat. NREL combined desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90% less electricity and up to 80% less total energy than traditional air conditioning (AC). This solution, called the desiccant enhanced evaporative air conditioner (DEVap), also controls humidity more effectively to improve the comfort of people in buildings. Desiccants are an example of a thermally activated technology (TAT) that relies on heat instead

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

NUCLA Circulating Atmospheric Fluidized Bed Demonstration Project  

Science Conference Proceedings (OSTI)

This Annual Report on Colorado-Ute Electric Association's NUCLA Circulating Fluidized Bed (CFB) Demonstration Program covers the period from February 1987 through December 1988. The outline for presentation in this report includes a summary of unit operations along with individual sections covering progress in study plan areas that commenced during this reporting period. These include cold-mode shakedown and calibration, plant commercial performance statistics, unit start-up (cold), coal and limestone preparation and handling, ash handling system performance and operating experience, tubular air heater, baghouse operation and performance, materials monitoring, and reliability monitoring. During this reporting period, the coal-mode shakedown and calibration plan was completed. (VC)

Not Available

1991-01-01T23:59:59.000Z

282

A General Circulation Model for Upper Ocean Simulation  

Science Conference Proceedings (OSTI)

A general circulation model (GCM) of the ocean that emphasizes the simulation of the upper ocean has been developed. This emphasis is in keeping with its future intent, that of an air-sea coupled model. The basic model is the primitive equation ...

A. Rosati; K. Miyakoda

1988-11-01T23:59:59.000Z

283

Oceanic Data Analysis Using a General Circulation Model. Part II: A North Atlantic Model  

Science Conference Proceedings (OSTI)

A general circulation model and North Atlantic climatological data of temperature salinity, wind stress, evaporation minus precipitation, and airsea heat fluxes are used to examine the possibility of solving inverse problems using a full-scale ...

Eli Tziperman; William Carlisle Thacker; Robert Bryan Long; Show-Ming Hwang; Stephen R. Rintoul

1992-12-01T23:59:59.000Z

284

Rate of Work Done by Atmospheric Pressure on the Ocean General Circulation and Tides  

Science Conference Proceedings (OSTI)

Quantitative analysis of the energetics of the ocean is crucial for understanding its circulation and mixing. The power input by fluctuations in atmospheric pressure pa resulting from the S1 and S2 air tides and the stochastic continuum is ...

Rui M. Ponte

2009-02-01T23:59:59.000Z

285

Aspects of the Load Circulation at the Grand Canyon during the Fall Season  

Science Conference Proceedings (OSTI)

The atmosphere and circulation of air within, above, and around the Grand Canyon of the Colorado River was studied from an instrumented aircraft and from ground-based instruments in September and October 1984. Several patterns were identified. ...

L. P. Stearns

1987-10-01T23:59:59.000Z

286

Underbalanced drilling with air offers many pluses  

Science Conference Proceedings (OSTI)

A pressure overbalance during conventional drilling can cause significant fluid filtrate invasion and lost circulation. Fluid invasion into the formation can lead to formation damage, high mud costs, a need for expensive completions, and well productivity impairment. Because underbalanced drilling creates a natural tendency for fluid and gas to flow from the formation to the borehole, successful underbalanced drilling depends upon the appropriate selection of circulating fluid. The use of a compressible fluid in the circulating system, referred to as air drilling, lowers the downhole pressure, allowing drilling into and beyond these sensitive formations. The paper discusses the equipment needed; well control; downhole air requirements; air drilling techniques using dry air, air-mist, stable foam, stiff foam, and aerated-fluid; downhole fires; directional air drilling; and well completions.

Shale, L. [Baker Hughes Inteq, Houston, TX (United States)

1995-06-26T23:59:59.000Z

287

Lost Circulation Technology Development Status  

DOE Green Energy (OSTI)

Lost circulation is the loss of drilling fluid from the wellbore to fractures or pores in the rock formation. In geothermal drilling, lost circulation is often a serious problem that contributes greatly to the cost of the average geothermal well. The Lost Circulation Technology Development Program is sponsored at Sandia National Laboratories by the U.S. Department of Energy. The goal of the program is to reduce lost circulation costs by 30-50% through the development of mitigation and characterization technology. This paper describes the technical progress made in this program during the period April, 1991-March, 1992.

Glowka, David A.; Schafer, Diane M.; Loeppke, Glen E.; Scott, Douglas D.; Wernig, Marcus D.; Wright, Elton K.

1992-03-24T23:59:59.000Z

288

Lost circulation technology development status  

DOE Green Energy (OSTI)

Lost circulation is the loss of drilling fluid from the wellbore to fractures or pores in the rock formation. In geothermal drilling, lost circulation is often a serious problem that contributes greatly to the cost of the average geothermal well. The Lost Circulation Technology Development Program is sponsored at Sandia National Laboratories by the US Department of Energy. The goal of the program is to reduce lost circulation costs by 30--50% through the development of mitigation and characterization technology. This paper describes the technical progress made in this program during the period April 1991--March 1992. 8 refs.

Glowka, D.A.; Schafer, D.M.; Loeppke, G.E.; Scott, D.D.; Wernig, M.D.; Wright, E.K.

1992-01-01T23:59:59.000Z

289

Lost circulation technology development status  

DOE Green Energy (OSTI)

Lost circulation is the loss of drilling fluid from the wellbore to fractures or pores in the rock formation. In geothermal drilling, lost circulation is often a serious problem that contributes greatly to the cost of the average geothermal well. The Lost Circulation Technology Development Program is sponsored at Sandia National Laboratories by the US Department of Energy. The goal of the program is to reduce lost circulation costs by 30--50% through the development of mitigation and characterization technology. This paper describes the technical progress made in this program during the period April 1991--March 1992. 8 refs.

Glowka, D.A.; Schafer, D.M.; Loeppke, G.E.; Scott, D.D.; Wernig, M.D.; Wright, E.K.

1992-07-01T23:59:59.000Z

290

B. TRANSPORTATION, CIRCULATION AND PARKING B. TRANSPORTATION, CIRCULATION AND  

E-Print Network (OSTI)

B. TRANSPORTATION, CIRCULATION AND PARKING 231 B. TRANSPORTATION, CIRCULATION AND PARKING on transportation and connectivity issues common to UCSF as a whole. Please refer to Chapter 5, Plans for Existing characteristics specific to each individual UCSF site. DETERMINANTS OF THE 1996 LRDP The transportation

Mullins, Dyche

291

Ocean General Circulation Models  

SciTech Connect

1. Definition of Subject The purpose of this text is to provide an introduction to aspects of oceanic general circulation models (OGCMs), an important component of Climate System or Earth System Model (ESM). The role of the ocean in ESMs is described in Chapter XX (EDITOR: PLEASE FIND THE COUPLED CLIMATE or EARTH SYSTEM MODELING CHAPTERS). The emerging need for understanding the Earths climate system and especially projecting its future evolution has encouraged scientists to explore the dynamical, physical, and biogeochemical processes in the ocean. Understanding the role of these processes in the climate system is an interesting and challenging scientific subject. For example, a research question how much extra heat or CO2 generated by anthropogenic activities can be stored in the deep ocean is not only scientifically interesting but also important in projecting future climate of the earth. Thus, OGCMs have been developed and applied to investigate the various oceanic processes and their role in the climate system.

Yoon, Jin-Ho; Ma, Po-Lun

2012-09-30T23:59:59.000Z

292

Forced air fireplace furnace  

Science Conference Proceedings (OSTI)

The design of heating system for buildings including a fireplace with an open front hearth for burning firewood, a chimney extending from the upper portion of the hearth, a metal firebox being open in the front and closed on the sides and back, a plenum chamber within and surrounding the sides and back of the metal firebox and the chimney lower portion, a horizontal heat distribution chamber positioned in the building attic and communicating at one end with the plenum chamber is described. An air distribution duct connects to the other end of the air distributing chamber, the duct extending to discharge heated air to a place in the building remote from the fireplace. A fan is placed in the horizontal air distributing chamber, and a return air duct extends from selected place in the building and communicates with the plenum chamber lower portion so that the fan draws air through the return air duct, through the plenum chamber around the firebox where the air is heated, through the horizontal distribution chamber, and out through the distribution duct for circulation of the heated air within the building.

Bruce, R.W.; Gorman, R.E.

1980-10-28T23:59:59.000Z

293

Status of lost circulation research  

DOE Green Energy (OSTI)

This paper describes progress made in the Lost Circulation Technology Development Program over the period March, 1992--April, 1993. The program is sponsored at Sandia National Laboratories by the US Department of Energy, Geothermal division. The goal of the program is to develop technology to reduce lost circulation costs associated with geothermal drilling by 30--50%.

Glowka, D.A.; Schafer, D.M.; Wright, E.K.; Whitlow, G.L.; Bates, C.W.

1993-06-01T23:59:59.000Z

294

2005 Status Report Savings Estimates for the ENERGY STAR(R) Voluntary Labeling Program  

E-Print Network (OSTI)

Exit Signs Dishwashers Room Airclothes washers, dishwashers, room air conditioners (RACs),clothes washers, dishwashers, and room air conditioners (

Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla

2006-01-01T23:59:59.000Z

295

2004 status report: Savings estimates for the Energy Star(R) voluntarylabeling program  

E-Print Network (OSTI)

air conditioners and dishwashers. Because energy efficiencyWashers. Y Dishwashers Y Room Airclothes washers, dishwashers, room air conditioners (RACs),

Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla

2004-01-01T23:59:59.000Z

296

2007 Status Report: Savings Estimates for the ENERGY STAR(R) VoluntaryLabeling Program  

E-Print Network (OSTI)

Telephony.. 2002 Dishwashers 1996 a Hotclothes washers, dishwashers, room air conditioners (RACs),clothes washers, dishwashers, and room air conditioners (

Sanchez, Marla; Webber, Carrie A.; Brown, Richard E.; Homan, Gregory K.

2007-01-01T23:59:59.000Z

297

PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976  

E-Print Network (OSTI)

of the waste heat. The solar heating and cooling program ofheating. The heat source can be either a back-up system, or the solar

Dao, K.

2010-01-01T23:59:59.000Z

298

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

E-Print Network (OSTI)

Estimation - Indian Standards and Labeling Program. USEPA,and Energy Efficiency Standards in India. Indian Bureau ofof Energy-Efficiency Standards for Indian Refrigerators.

McNeil, Michael A.

2010-01-01T23:59:59.000Z

299

Avoiding 100 new power plants by increasing efficiency of room air conditioners in India: opportunities and challenges  

SciTech Connect

Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40% cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

Phadke, Amol; Abhyankar, Nikit; Shah, Nihar; [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

2013-10-15T23:59:59.000Z

300

PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976  

E-Print Network (OSTI)

cooled, ammonia-water absorption chiller as a starting pointabsorption cycle under such conJitions. A nominal three-ton,continuous operation, heat-actuated water chiller

Dao, K.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

E-Print Network (OSTI)

prevailing marginal electricity prices, in order to give anCCE with prevailing electricity prices. In order to estimateusers. Marginal Electricity Prices and Discount Rates

McNeil, Michael A.

2010-01-01T23:59:59.000Z

302

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

E-Print Network (OSTI)

program as scheduled. By 2030, this program, if fullyTWh. Overall savings through 2030 totals 385 TWh. Finally,savings achievable by 2030. Introduction The Indian Bureau

McNeil, Michael A.

2010-01-01T23:59:59.000Z

303

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

E-Print Network (OSTI)

in use patterns and electricity rates between commercial andRates Residential electricity rates are much lower thanin India. Residential electricity rates are subsidized to a

McNeil, Michael A.

2010-01-01T23:59:59.000Z

304

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

E-Print Network (OSTI)

Discount Rates Residential electricity rates are much lowerrates in India. Residential electricity rates are subsidizedand electricity rates between commercial and residential

McNeil, Michael A.

2010-01-01T23:59:59.000Z

305

Assessing the Impact of Measurement Policy on the Accuracy of Certified Energy Efficiency Ratio for Split-System Air Conditioners  

E-Print Network (OSTI)

2009). ASHRAE Handbook - Fundamentals. ASHRAE, 1791 Tulliethe 2009 ANSI/ASHRAE HandbookFundamentals Equation 38 [9],

Yu, Bingyi

2013-01-01T23:59:59.000Z

306

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

E-Print Network (OSTI)

2000-2050 National Energy Consumption When regulations takeThe total energy consumption (NEC) of the national stock ofenergy consumption and associated emissions of greenhouse gases and other pollutants at the national

McNeil, Michael A.

2010-01-01T23:59:59.000Z

307

PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976  

E-Print Network (OSTI)

and Thermodynamic Properties of Ammonia-Water Mixtures",thermodynamic properties of the ammonia-water solution wereof saturated properties of the ammonia-water. This slope can

Dao, K.

2010-01-01T23:59:59.000Z

308

DOE Institutes Enforcement Action Against AeroSys, Inc. for Failure to Certify Air Conditioners and Heat Pumps  

Energy.gov (U.S. Department of Energy (DOE))

Washington, DC - The Department of Energys Office of General Counsel has issued a Notice of Proposed Civil Penalty to AeroSys, Inc. for failing to file certification reports or filing data that...

309

Desiccant Enhanced Evaporative Air-Conditioning (DEVap): Evaluation of a New Concept in Ultra Efficient Air Conditioning  

SciTech Connect

NREL has developed the novel concept of a desiccant enhanced evaporative air conditioner (DEVap) with the objective of combining the benefits of liquid desiccant and evaporative cooling technologies into an innovative 'cooling core.' Liquid desiccant technologies have extraordinary dehumidification potential, but require an efficient cooling sink. DEVap's thermodynamic potential overcomes many shortcomings of standard refrigeration-based direct expansion cooling. DEVap decouples cooling and dehumidification performance, which results in independent temperature and humidity control. The energy input is largely switched away from electricity to low-grade thermal energy that can be sourced from fuels such as natural gas, waste heat, solar, or biofuels.

Kozubal, E.; Woods, J.; Burch, J.; Boranian, A.; Merrigan, T.

2011-01-01T23:59:59.000Z

310

Thermodynamic Analysis of Ocean Circulation  

Science Conference Proceedings (OSTI)

Calculating a streamfunction as function of depth and density is proposed as a new way of analyzing the thermodynamic character of the overturning circulation in the global ocean. The sign of an overturning cell in this streamfunction directly ...

J. Nycander; J. Nilsson; K. Ds; G. Brostrm

2007-08-01T23:59:59.000Z

311

Residual Circulation and Tropopause Structure  

Science Conference Proceedings (OSTI)

The effect of large-scale dynamics as represented by the residual mean meridional circulation in the transformed Eulerian sense, in particular its stratospheric part, on lower stratospheric static stability and tropopause structure is studied ...

Thomas Birner

2010-08-01T23:59:59.000Z

312

Secondary Instabilities in Langmuir Circulations  

Science Conference Proceedings (OSTI)

Finite-amplitude Langmuir circulation in the form of rolls parallel to the wind direction is shown to be subject to three-dimensional instability under certain circumstances. Density stratification is not required for instability to manifest. The ...

Amit Tandon; Sidney Leibovich

1995-06-01T23:59:59.000Z

313

DOE lost circulation technology development  

DOE Green Energy (OSTI)

Lost circulation is a problem common in both the geothermal and the solution mining industries. In both cases, drilling is on a relatively large scale (geothermal holes can be as large as 26 inches). Lost circulation technology development for geothermal drilling has been in progress at Sandia National Laboratories for more than 15 years. The initial work centered on lost circulation materials, but testing and modeling indicated that if the aperture of a loss zone is very large (larger than the drill bit nozzles) it cannot be plugged by simply adding materials to the drilling fluid. Thus, the lost circulation work evolved to include: (1) Development of metering techniques that accurately measure and characterize drilling fluid inflow and outflow for rapid diagnosis of los circulation and/or fluid balance while drilling. (2) Construction of a laboratory facility for testing drillable straddle packers (to improve the plugging efficiency of cementing operations) and the actual testing of components of the straddle packer. (3) Construction of a laboratory facility for the testing of candidate porous fabrics as a part of a program to develop a porous packer that places polyurethane foam into a loss zone. (4) Implementing (with Halliburton and CalEnergy Company), a program to test cementitious lost circulation material as an alternative to Portland cement.

Glowka, D.A.; Staller, G.E.; Sattler, A.R.

1996-09-01T23:59:59.000Z

314

Air-cleaning apparatus  

SciTech Connect

An air-cleaning, heat-exchange apparatus includes a main housing portion connected by means of an air inlet fan to the kitchen exhaust stack of a restaurant. The apparatus includes a plurality of heat exchangers through which a heat-absorptive fluid is circulated, simultaneously, by means of a suitable fluid pump. These heat exchangers absorb heat from the hot exhaust gas, out of the exhaust stack of the restaurant, which flows over and through these heat exchangers and transfers this heat to the circulating fluid which communicates with remote heat exchangers. These remote heat exchangers further transfer this heat to a stream of air, such as that from a cold-air return duct for supplementing the conventional heating system of the restaurant. Due to the fact that such hot exhaust gas is heavily grease laden , grease will be deposited on virtually all internal surfaces of the apparatus which this exhaust gas contacts. Consequently, means are provided for spraying these contacted internal surfaces , as well as the hot exhaust gas itself, with a detergent solution in which the grease is soluble, thereby removing grease buildup from these internal surfaces.

Howard, A.G.

1981-08-18T23:59:59.000Z

315

Future Air Conditioning Energy Consumption in Developing Countriesand what can be done about it: The Potential of Efficiency in theResidential Sector  

SciTech Connect

The dynamics of air conditioning are of particular interestto energy analysts, both because of the high energy consumption of thisproduct, but also its disproportionate impact on peak load. This paperaddresses the special role of this end use as a driver of residentialelectricity consumption in rapidly developing economies. Recent historyhas shown that air conditioner ownership can grow grows more rapidly thaneconomic growth in warm-climate countries. In 1990, less than a percentof urban Chinese households owned an air conditioner; by 2003 this numberrose to 62 percent. The evidence suggests a similar explosion of airconditioner use in many other countries is not far behind. Room airconditioner purchases in India are currently growing at 20 percent peryear, with about half of these purchases attributed to the residentialsector. This paper draws on two distinct methodological elements toassess future residential air conditioner 'business as usual' electricityconsumption by country/region and to consider specific alternative 'highefficiency' scenarios. The first component is an econometric ownershipand use model based on household income, climate and demographicparameters. The second combines ownership forecasts and stock accountingwith geographically specific efficiency scenarios within a uniqueanalysis framework (BUENAS) developed by LBNL. The efficiency scenariomodule considers current efficiency baselines, available technologies,and achievable timelines for development of market transformationprograms, such as minimum efficiency performance standards (MEPS) andlabeling programs. The result is a detailed set of consumption andemissions scenarios for residential air conditioning.

McNeil, Michael A.; Letschert, Virginie E.

2007-05-01T23:59:59.000Z

316

Future Air Conditioning Energy Consumption in Developing Countriesand what can be done about it: The Potential of Efficiency in theResidential Sector  

SciTech Connect

The dynamics of air conditioning are of particular interestto energy analysts, both because of the high energy consumption of thisproduct, but also its disproportionate impact on peak load. This paperaddresses the special role of this end use as a driver of residentialelectricity consumption in rapidly developing economies. Recent historyhas shown that air conditioner ownership can grow grows more rapidly thaneconomic growth in warm-climate countries. In 1990, less than a percentof urban Chinese households owned an air conditioner; by 2003 this numberrose to 62 percent. The evidence suggests a similar explosion of airconditioner use in many other countries is not far behind. Room airconditioner purchases in India are currently growing at 20 percent peryear, with about half of these purchases attributed to the residentialsector. This paper draws on two distinct methodological elements toassess future residential air conditioner 'business as usual' electricityconsumption by country/region and to consider specific alternative 'highefficiency' scenarios. The first component is an econometric ownershipand use model based on household income, climate and demographicparameters. The second combines ownership forecasts and stock accountingwith geographically specific efficiency scenarios within a uniqueanalysis framework (BUENAS) developed by LBNL. The efficiency scenariomodule considers current efficiency baselines, available technologies,and achievable timelines for development of market transformationprograms, such as minimum efficiency performance standards (MEPS) andlabeling programs. The result is a detailed set of consumption andemissions scenarios for residential air conditioning.

McNeil, Michael A.; Letschert, Virginie E.

2007-05-01T23:59:59.000Z

317

Asian Summer Monsoon Intraseasonal Variability in General Circulation Models  

SciTech Connect

The goals of this report are: (1) Analyze boreal summer Asian monsoon intraseasonal variability general circulation models--How well do the models represent the eastward and northward propagating components of the convection and how well do the models represent the interactive control that the western tropical Pacific rainfall exerts on the rainfall over India and vice-versa? (2) Role of air-sea interactions--prescribed vs. interactive ocean; and (3) Mean monsoon vs. variability.

Sperber, K R; Annamalai, H

2004-02-24T23:59:59.000Z

318

Pressurized circulating fluidized-bed combustion for power generation  

SciTech Connect

Second-generation Pressurized Circulating Fluidized Bed Combustion (PCFBC) is the culmination of years of effort in the development of a new generation of power plants which can operate on lower-quality fuels with substantially improved efficiencies, meet environmental requirements, and provide a lower cost of electricity. Air Products was selected in the DOE Clean Coal Technology Round V program to build, own, and operate the first commercial power plant using second-generation PCFBC technology, to be located at an Air Products chemicals manufacturing facility in Calvert City, Kentucky. This paper describes the second-generation PCFBC concept and its critical technology components.

Weimer, R.F.

1995-08-01T23:59:59.000Z

319

Calendar Year 2007 Program Benefits for U.S. EPA Energy Star Labeled Products: Expanded Methodology  

E-Print Network (OSTI)

Gas or Oil) Central Air Conditioner Air-Source Heat PumpGas or Oil) - Central Air Conditioner - Air-Source HeatGas or Oil) - Central Air Conditioner - Air-Source Heat

Sanchez, Marla

2010-01-01T23:59:59.000Z

320

A Comparison of GCM-simulated and Observed Mean January and July Surface Air Temperature  

Science Conference Proceedings (OSTI)

January and July surface air temperature fields simulated by the GFDI, OSU, GISS, and UKMO general circulation models (GCMS) are compared to the global surface air temperature climatology compiled by Legates and Willmott. Legates and Willmott's ...

Cort J. Willmott; David R. Legates

1993-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Effect of helium injection on diffusion dominated air ingress accidents in pebble bed reactors  

E-Print Network (OSTI)

The primary objective of this thesis was to validate the sustained counter air diffusion (SCAD) method at preventing natural circulation onset in diffusion dominated air ingress accidents. The analysis presented in this ...

Yurko, Joseph Paul

2010-01-01T23:59:59.000Z

322

Magnetic Refrigeration Technology for High Efficiency Air Conditioning  

SciTech Connect

Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate heat exchangers or oil distribution issues found in traditional vapor compression systems.

Boeder, A; Zimm, C

2006-09-30T23:59:59.000Z

323

Hot air drum evaporator  

DOE Patents (OSTI)

An evaporation system for aqueous radioactive waste uses standard 30 and 55 gallon drums. Waste solutions form cascading water sprays as they pass over a number of trays arranged in a vertical stack within a drum. Hot dry air is circulated radially of the drum through the water sprays thereby removing water vapor. The system is encased in concrete to prevent exposure to radioactivity. The use of standard 30 and 55 gallon drums permits an inexpensive compact modular design that is readily disposable, thus eliminating maintenance and radiation build-up problems encountered with conventional evaporation systems.

Black, Roger L. (Idaho Falls, ID)

1981-01-01T23:59:59.000Z

324

Instability of Two-Dimensional Themohaline Circulation  

Science Conference Proceedings (OSTI)

Two different two-dimensional models of the thermohaline circulation of the ocean have been used to study the loss of stability of a thermally dominated symmetrical two-cell circulation. Although the models differ in their momentum budget, their ...

Michael Vellinga

1996-03-01T23:59:59.000Z

325

Oceanic Regulation of the Atmospheric Walker Circulation  

Science Conference Proceedings (OSTI)

A coupled theory is proposed to account for the magnitude of the Walker circulation in the tropical Pacific. It is suggested that the Pacific Walker circulation is at a saturation state, at which the zonal sea surface temperature difference is ...

Zhengyu Liu

1997-03-01T23:59:59.000Z

326

Connecting Changing Ocean Circulation with Changing Climate  

Science Conference Proceedings (OSTI)

The influence of changing ocean currents on climate change is evaluated by comparing an earth system models response to increased CO2 with and without an ocean circulation response. Inhibiting the ocean circulation response, by specifying a ...

Michael Winton; Stephen M. Griffies; Bonita L. Samuels; Jorge L. Sarmiento; Thomas L. Frlicher

2013-04-01T23:59:59.000Z

327

Atmospheric Control on the Thermohaline Circulation  

Science Conference Proceedings (OSTI)

In an attempt to elucidate the role of atmospheric and oceanic processes in setting a vigorous ocean overturning circulation in the North Atlantic but not in the North Pacific, a comparison of the observed atmospheric circulation and net surface ...

Arnaud Czaja

2009-01-01T23:59:59.000Z

328

Protective supplied-breathing-air garment  

DOE Patents (OSTI)

A breathing-air garment for isolating a wearer from hostile environments containing toxins or irritants is disclosed. The garment includes a suit and a separate head-protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air-delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air-delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit sealed with an adhesive sealing flap.

Childers, E.L.; von Hortenau, E.F.

1982-05-28T23:59:59.000Z

329

The Sun's Shallow Meridional Circulation  

E-Print Network (OSTI)

The Sun's global meridional circulation is evident as a slow poleward flow at its surface. This flow is observed to carry magnetic elements poleward - producing the Sun's polar magnetic fields as a key part of the 11-year sunspot cycle. Current theories for the sunspot cycle assume that this surface flow is part of a circulation which sinks inward at the poles and turns equatorward at depths below 100 Mm. Here we use the advection of the Sun's convection cells by the meridional flow to map the flow velocity in latitude and depth. Our measurements show the largest cells clearly moving equatorward at depths below 35 Mm - the base of the Sun's surface shear layer. This surprisingly shallow return flow indicates the need for substantial revisions to solar/stellar dynamo theory.

Hathaway, David H

2011-01-01T23:59:59.000Z

330

Circulation  

NLE Websites -- All DOE Office Websites (Extended Search)

up from the Research Library. Lost Damaged Missing Items Replacement of LANL Research Library items that are lost, damaged beyond repair, or stolen is the responsibility of...

331

Air Quality  

NLE Websites -- All DOE Office Websites (Extended Search)

What We Monitor & Why » What We Monitor & Why » Air Quality Air Quality To preserve our existing wilderness-area air quality, LANL implements a conscientious program of air monitoring. April 12, 2012 Real-time data monitoring for particulate matter An air monitoring field team member tests one of LANL's tapered element oscillating microbalance samplers, which collects real-time particulate matter data. Contact Environmental Communication & Public Involvement P.O. Box 1663 MS M996 Los Alamos, NM 87545 (505) 667-0216 Email LANL monitors air quality 24 hours a day, 365 days a year. Why we monitor air LANL monitors many different pathways in order to assess their impact on workers, the public, animals, and plants. We monitor the air around the Laboratory to ensure our operations are not affecting the air of nearby

332

Ga Air Compressor, Ga Air Compressor Products, Ga Air ...  

U.S. Energy Information Administration (EIA)

Ga Air Compressor, You Can Buy Various High Quality Ga Air Compressor Products from Global Ga Air Compressor Suppliers and Ga Air Compressor ...

333

COMPUTATIONAL MODELING OF CIRCULATING FLUIDIZED BED REACTORS  

Science Conference Proceedings (OSTI)

Details of numerical simulations of two-phase gas-solid turbulent flow in the riser section of Circulating Fluidized Bed Reactor (CFBR) using Computational Fluid Dynamics (CFD) technique are reported. Two CFBR riser configurations are considered and modeled. Each of these two riser models consist of inlet, exit, connecting elbows and a main pipe. Both riser configurations are cylindrical and have the same diameter but differ in their inlet lengths and main pipe height to enable investigation of riser geometrical scaling effects. In addition, two types of solid particles are exploited in the solid phase of the two-phase gas-solid riser flow simulations to study the influence of solid loading ratio on flow patterns. The gaseous phase in the two-phase flow is represented by standard atmospheric air. The CFD-based FLUENT software is employed to obtain steady state and transient solutions for flow modulations in the riser. The physical dimensions, types and numbers of computation meshes, and solution methodology utilized in the present work are stated. Flow parameters, such as static and dynamic pressure, species velocity, and volume fractions are monitored and analyzed. The differences in the computational results between the two models, under steady and transient conditions, are compared, contrasted, and discussed.

Ibrahim, Essam A

2013-01-09T23:59:59.000Z

334

NUCLA Circulating Atmospheric Fluidized Bed Demonstration Project. Annual report, 1988  

Science Conference Proceedings (OSTI)

This Annual Report on Colorado-Ute Electric Association`s NUCLA Circulating Fluidized Bed (CFB) Demonstration Program covers the period from February 1987 through December 1988. The outline for presentation in this report includes a summary of unit operations along with individual sections covering progress in study plan areas that commenced during this reporting period. These include cold-mode shakedown and calibration, plant commercial performance statistics, unit start-up (cold), coal and limestone preparation and handling, ash handling system performance and operating experience, tubular air heater, baghouse operation and performance, materials monitoring, and reliability monitoring. During this reporting period, the coal-mode shakedown and calibration plan was completed. (VC)

Not Available

1991-01-01T23:59:59.000Z

335

Protective supplied breathing air garment  

DOE Patents (OSTI)

A breathing air garment is disclosed for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap. 17 figs.

Childers, E.L.; Hortenau, E.F. von.

1984-07-10T23:59:59.000Z

336

Protective supplied breathing air garment  

DOE Patents (OSTI)

A breathing air garment for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap.

Childers, Edward L. (Lakewood, CO); von Hortenau, Erik F. (Golden, CO)

1984-07-10T23:59:59.000Z

337

Demonstration of an advanced circulation fludized bed coal combustor phase 1: Cold model study. Final report  

Science Conference Proceedings (OSTI)

It was found that there was a strong dependence of the density profile on the secondary air injection location and that there was a pronounced solid separation from the conveying gas, due to the swirl motion. Furthermore, the swirl motion generated strong internal circulation patterns and higher slip velocities than in the case of nonswirl motion as in an ordinary circulating fluidized bed. Radial solids flux profiles were measured at different axial locations. The general radial profile in a swirling circulating fluidized bed indicated an increased downward flow of solids near the bed walls, and strong variations in radial profiles along the axial height. For swirl numbers less than 0.9, which is typical for swirling circulating fluidized beds, there is no significant increase in erosion due to swirl motion inside the bed. Pending further investigation of swirl motion with combustion, at least from our cold model studies, no disadvantages due to the introduction of swirl motion were discovered.

Govind, R. [Cincinnati Univ., OH (United States). Dept. of Chemical Engineering

1993-03-20T23:59:59.000Z

338

A cost effective trace gas measurement program for long term monitoring of the stratospheric circulation  

Science Conference Proceedings (OSTI)

A stratospheric trace gas measurement program using balloon-based sonde and AirCore sampler techniques, is proposed as a way to monitor the strength of the stratospheric mean meridional, or Brewer-Dobson circulation. Modeling work predicts a strengthening ...

Fred L. Moore; Eric A. Ray; Karen H. Rosenlof; James W. Elkins; Pieter Tans; Anna Karion; Colm Sweeney

339

CIRCULATING MOVING BED COMBUSTION PROOF OF CONCEPT  

Science Conference Proceedings (OSTI)

Circulating Moving Bed (CMB) combustion technology has its roots in traditional circulating fluidized bed technology and involves a novel method of solid fuel combustion and heat transfer. CMB technology represents a step change in improved performance and cost relative to conventional PC and FBC boilers. The CMB heat exchanger preheats the energy cycle working fluid, steam or air, to the high temperature levels required in systems for advanced power generation. Unique features of the CMB are the reduction of the heat transfer surfaces by about 60% as a result of the enhanced heat transfer rates, flexibility of operation, and about 30% lower cost over existing technology. The CMB Phase I project ran from July 2001 through March 2003. Its objective was to continue development of the CMB technology with a series of proof of concept tests. The tests were conducted at a scale that provided design data for scale up to a demonstration plant. These objectives were met by conducting a series of experiments in ALSTOM Powers Multi-use Test Facility (MTF). The MTF was modified to operate under CMB conditions of commercial interest. The objective of the tests were to evaluate gas-to-solids heat transfer in the upper furnace, assess agglomeration in the high temperature CMB bubbling bed, and evaluate solids-to-tube heat transfer in the moving bed heat exchanger. The Phase I program results showed that there are still some significant technical uncertainties that needed to be resolved before the technology can be confidently scaled up for a successful demonstration plant design. Work remained in three primary areas: scale up of gas to solid heat transfer high temperature finned surface design the overall requirements of mechanical and process design. The CMB Phase II workscope built upon the results of Phase I and specifically addressed the remaining technical uncertainties. It included a scaled MTF heat transfer test to provide the necessary data to scale up gas-to-solids heat transfer. A stress test rig was built and tested to provide validation data for a stress model needed to support high temperature finned surface design. Additional cold flow model tests and MTF tests were conducted to address mechanical and process design issues. This information was then used to design and cost a commercial CMB design concept. Finally, the MBHE was reconfigured into a slice arrangement and tested for an extended duration at a commercial CFB plant.

Jukkola, Glen

2010-06-30T23:59:59.000Z

340

Method for Determining Solids Circulation Rate  

NLE Websites -- All DOE Office Websites (Extended Search)

Determining Solids Circulation Rate Determining Solids Circulation Rate Contact NETL Technology Transfer Group techtransfer@netl.doe.gov May 2012 Opportunity Research is currently active on the patented technology "Method for Determining Solids Circulation Rate." The technology is available for licensing and/or further collaborative research from the U.S. Department of Energy's National Energy Technology Laboratory. Overview This invention provides a method to measure the rate of solids circulation, particularly in those applications where the solids are recycled back to pro- cesses for further use. The applications include processes such as circulating fluidized bed gasifiers and combustors, as well as chemical looping. In the above applications, determining solids circulation rates is needed to

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Lost Circulation Experience in Geothermal Wells  

DOE Green Energy (OSTI)

Lost circulation during drilling and cementing in geothermal wells is a problem common to most geothermal areas. Material and rig time costs due to lost circulation often represent one fourth or more of the total well cost. Assessment of the general drilling and completion practices commonly used for handling lost circulation have been surveyed and evaluated under a study sponsored by Sandia National Laboratories. Results of this study, including interviews with geothermal production companies and with drilling fluid service companies, are reported in the paper. Conclusions and recommendations are presented for control of lost circulation during geothermal operations. Recent improvements in lost circulation materials and techniques and potential equipment solutions to the lost circulation problem are discussed. Research needs are also identified.

Goodman, M. A.

1981-01-01T23:59:59.000Z

342

Duke Energy - Residential and Builder Energy Efficiency Rebate...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pump: 300 (builder) New Home Air Conditioner: 300 (builder) Attic Insulation and Air Sealing: 250 Duct Sealing: 100 Heat Pump and Air Conditioner Tune Up: 50 AC...

343

A blood circulation model for reference man  

SciTech Connect

A dynamic blood circulation model that predicts the movement and gradual dispersion of a bolus of material in the circulation after its intravenous injection into an adult human. The main purpose of the model is improve the dosimetry of internally deposited radionuclides that decay in the circulation to a significant extent. The model partitions the blood volume into 24 separate organs or tissues, right heart chamber, left heart chamber, pulmonary circulation, arterial outflow to the aorta and large arteries, and venous return via the large veins. Model results were compared to data obtained from injection of carbon 11 labeled carbon monoxide or rubidium 86.

Leggett, R.W.; Eckerman, K.F. [Oak Ridge National Lab., TN (United States); Williams, L.R. [Indiana Univ., South Bend, IN (United States). Div. of Liberal Arts and Sciences

1996-12-31T23:59:59.000Z

344

Global Climate and Ocean Circulation on an Aquaplanet OceanAtmosphere General Circulation Model  

Science Conference Proceedings (OSTI)

A low-resolution coupled oceanatmosphere general circulation model (OAGCM) is used to study the characteristics of the large-scale ocean circulation and its climatic impacts in a series of global coupled aquaplanet experiments. Three ...

Robin S. Smith; Clotilde Dubois; Jochem Marotzke

2006-09-01T23:59:59.000Z

345

Downhole material injector for lost circulation control  

DOE Patents (OSTI)

Apparatus and method are disclosed for simultaneously and separately emplacing two streams of different materials through a drill string in a borehole to a downhole location for lost circulation control. The two streams are mixed outside the drill string at the desired downhole location and harden only after mixing for control of a lost circulation zone. 6 figs.

Glowka, D.A.

1994-09-06T23:59:59.000Z

346

Downhole material injector for lost circulation control  

DOE Patents (OSTI)

This invention is comprised of an apparatus and method for simultaneously and separately emplacing two streams of different materials through a drillstring in a borehole to a downhole location for lost circulation control. The two streams are mixed outside the drillstring at the desired downhole location and harden only after mixing for control of a lost circulation zone.

Glowka, D.A.

1991-12-31T23:59:59.000Z

347

Downhole material injector for lost circulation control  

DOE Patents (OSTI)

This invention is comprised of an apparatus and method for simultaneously and separately emplacing two streams of different materials through a drillstring in a borehole to a downhole location for lost circulation control. The two streams are mixed outside the drillstring at the desired downhole location and harden only after mixing for control of a lost circulation zone.

Glowka, D.A.

1991-01-01T23:59:59.000Z

348

Downhole material injector for lost circulation control  

DOE Patents (OSTI)

Apparatus and method for simultaneously and separately emplacing two streams of different materials through a drillstring in a borehole to a downhole location for lost circulation control. The two streams are mixed outside the drillstring at the desired downhole location and harden only after mixing for control of a lost circulation zone.

Glowka, David A. (Tijeras, NM)

1994-01-01T23:59:59.000Z

349

Air Conditioning Stall Phenomenon Testing, Model Development, and Simulation  

Science Conference Proceedings (OSTI)

Electric distribution systems are experiencing power quality issues of extended reduced voltage due to fault-induced delayed voltage recovery (FIDVR). FIDVR occurs in part because modern air conditioner (A/C) and heat pump compressor motors are much more susceptible to stalling during a voltage sag or dip such as a sub-transmission fault. They are more susceptible than older A/C compressor motors due to the low inertia of these newer and more energy efficient motors. There is a concern that these local reduced voltage events on the distribution system will become more frequent and prevalent and will combine over larger areas and challenge transmission system voltage and ultimately power grid reliability. The Distributed Energy Communications and Controls (DECC) Laboratory at Oak Ridge National Laboratory (ORNL) has been employed to (1) test, (2) characterize and (3) model the A/C stall phenomenon.

Irminger, Philip [ORNL; Rizy, D Tom [ORNL; Li, Huijuan [ORNL; Smith, Travis [ORNL; Rice, C Keith [ORNL; Li, Fangxing [ORNL; Adhikari, Sarina [ORNL

2012-01-01T23:59:59.000Z

350

Reversing the Circulation of Magnetic Vortices  

NLE Websites -- All DOE Office Websites (Extended Search)

Reversing the Circulation of Reversing the Circulation of Magnetic Vortices Reversing the Circulation of Magnetic Vortices Print Wednesday, 31 July 2013 00:00 In magnetic media, information is stored in binary form-one or zero, depending on which way the electronic spins are aligned in a given section of the medium. Recently, however, magnetic vortices have drawn scientists toward a new possibility: multibit storage in which each logic unit has four states instead of two and can store twice the information. Each tiny magnetic whirl has a polarity that can point up or down and a circulation that can be oriented clockwise or counterclockwise. Previous studies have shown that the polarity can be flipped on command. Now, using time-resolved magnetic soft x-ray microscopy at the ALS, researchers have shown for the first time how to use pulsed magnetic fields to reverse the circulation.

351

Operating experience with gas-bearing circulators in a high-pressure helium loop  

Science Conference Proceedings (OSTI)

A high-pressure engineering test loop has been designed and constructed at the Oak Ridge National Laboratory for circulating helium through a test chamber at temperatures to 1000/sup 0/C. The purpose of this loop is to determine the thermal and structural performance of proposed components for the primary loops of gas-cooled nuclear reactors. Five MW of power is available to provide the required gas temperature at the test chamber, and an air-cooled heat exchanger, rated at 4.4 MW, serves as a heat sink. This report contains results of tests performed on gas-bearing circulators.

Sanders, J.P.; Gat, Uri; Young, H.C.

1987-01-01T23:59:59.000Z

352

Zinc electrode and rechargeable zinc-air battery  

DOE Patents (OSTI)

An improved zinc electrode is disclosed for a rechargeable zinc-air battery comprising an outer frame and a porous foam electrode support within the frame which is treated prior to the deposition of zinc thereon to inhibit the formation of zinc dendrites on the external surface thereof. The outer frame is provided with passageways for circulating an alkaline electrolyte through the treated zinc-coated porous foam. A novel rechargeable zinc-air battery system is also disclosed which utilizes the improved zinc electrode and further includes an alkaline electrolyte within said battery circulating through the passageways in the zinc electrode and an external electrolyte circulation means which has an electrolyte reservoir external to the battery case including filter means to filter solids out of the electrolyte as it circulates to the external reservoir and pump means for recirculating electrolyte from the external reservoir to the zinc electrode.

Ross, Jr., Philip N. (Kensington, CA)

1989-01-01T23:59:59.000Z

353

Geothermal Lost Circulation Zone Mapping Tool  

DOE Green Energy (OSTI)

Lost circulation is an expensive and often encountered problem when drilling into geothermal formations. A method is needed to more accurately describe loss zones encountered during geothermal drilling to allow for more realistic testing since present testing techniques are inadequate. A Lost Circulation Zone Mapping Tool (LCZMT) is being developed that will quickly locate a loss zone and then provide a visual image of this zone as it intersects the wellbore. A modified Sandia high temperature Acoustic Borehole Televiewer should allow modeling of geothermal loss zones, which would in turn lead to testing that can be performed to evaluate lost circulation materials under simulated downhole conditions. 5 refs., 5 figs.

Bauman, T.J.

1985-01-01T23:59:59.000Z

354

Reversing the Circulation of Magnetic Vortices  

NLE Websites -- All DOE Office Websites (Extended Search)

Reversing the Circulation of Magnetic Vortices Print Reversing the Circulation of Magnetic Vortices Print In magnetic media, information is stored in binary form-one or zero, depending on which way the electronic spins are aligned in a given section of the medium. Recently, however, magnetic vortices have drawn scientists toward a new possibility: multibit storage in which each logic unit has four states instead of two and can store twice the information. Each tiny magnetic whirl has a polarity that can point up or down and a circulation that can be oriented clockwise or counterclockwise. Previous studies have shown that the polarity can be flipped on command. Now, using time-resolved magnetic soft x-ray microscopy at the ALS, researchers have shown for the first time how to use pulsed magnetic fields to reverse the circulation.

355

Reversing the Circulation of Magnetic Vortices  

NLE Websites -- All DOE Office Websites (Extended Search)

Reversing the Circulation of Magnetic Vortices Print Reversing the Circulation of Magnetic Vortices Print In magnetic media, information is stored in binary form-one or zero, depending on which way the electronic spins are aligned in a given section of the medium. Recently, however, magnetic vortices have drawn scientists toward a new possibility: multibit storage in which each logic unit has four states instead of two and can store twice the information. Each tiny magnetic whirl has a polarity that can point up or down and a circulation that can be oriented clockwise or counterclockwise. Previous studies have shown that the polarity can be flipped on command. Now, using time-resolved magnetic soft x-ray microscopy at the ALS, researchers have shown for the first time how to use pulsed magnetic fields to reverse the circulation.

356

Reversing the Circulation of Magnetic Vortices  

NLE Websites -- All DOE Office Websites (Extended Search)

Reversing the Circulation of Magnetic Vortices Print Reversing the Circulation of Magnetic Vortices Print In magnetic media, information is stored in binary form-one or zero, depending on which way the electronic spins are aligned in a given section of the medium. Recently, however, magnetic vortices have drawn scientists toward a new possibility: multibit storage in which each logic unit has four states instead of two and can store twice the information. Each tiny magnetic whirl has a polarity that can point up or down and a circulation that can be oriented clockwise or counterclockwise. Previous studies have shown that the polarity can be flipped on command. Now, using time-resolved magnetic soft x-ray microscopy at the ALS, researchers have shown for the first time how to use pulsed magnetic fields to reverse the circulation.

357

Reversing the Circulation of Magnetic Vortices  

NLE Websites -- All DOE Office Websites (Extended Search)

Reversing the Circulation of Magnetic Vortices Print Reversing the Circulation of Magnetic Vortices Print In magnetic media, information is stored in binary form-one or zero, depending on which way the electronic spins are aligned in a given section of the medium. Recently, however, magnetic vortices have drawn scientists toward a new possibility: multibit storage in which each logic unit has four states instead of two and can store twice the information. Each tiny magnetic whirl has a polarity that can point up or down and a circulation that can be oriented clockwise or counterclockwise. Previous studies have shown that the polarity can be flipped on command. Now, using time-resolved magnetic soft x-ray microscopy at the ALS, researchers have shown for the first time how to use pulsed magnetic fields to reverse the circulation.

358

Reversing the Circulation of Magnetic Vortices  

NLE Websites -- All DOE Office Websites (Extended Search)

Reversing the Circulation of Magnetic Vortices Print Reversing the Circulation of Magnetic Vortices Print In magnetic media, information is stored in binary form-one or zero, depending on which way the electronic spins are aligned in a given section of the medium. Recently, however, magnetic vortices have drawn scientists toward a new possibility: multibit storage in which each logic unit has four states instead of two and can store twice the information. Each tiny magnetic whirl has a polarity that can point up or down and a circulation that can be oriented clockwise or counterclockwise. Previous studies have shown that the polarity can be flipped on command. Now, using time-resolved magnetic soft x-ray microscopy at the ALS, researchers have shown for the first time how to use pulsed magnetic fields to reverse the circulation.

359

Carderock Circulating Water Channel | Open Energy Information  

Open Energy Info (EERE)

Circulating Water Channel Circulating Water Channel Jump to: navigation, search Basic Specifications Facility Name Carderock Circulating Water Channel Overseeing Organization United States Naval Surface Warfare Center Hydrodynamic Testing Facility Type Channel Length(m) 18.3 Beam(m) 6.7 Depth(m) 2.7 Water Type Freshwater Cost(per day) Contact POC Special Physical Features The Circulating Water Channel is a vertical plane, open to the atmosphere test section with a free surface in a closed recirculating water circuit, variable speed, rectangular cross-sectional shape facility. There are 10 large viewing windows on either side of the test section at different elevations and 9 in the bottom; movable bridge spans the test section for ease and versatility in mounting models, rigging bridge is capable of taking towing loads at any one of numerous points up to 35,584 N

360

Distribution and Circulation of Labrador Sea Water  

Science Conference Proceedings (OSTI)

Labrador Sea Water is the final product of the cyclonic circulation of Subpolar Mode Water in the open northern North Atlantic (McCartney and Talley, 1982). The temperature and salinity of the convectively formed Subpolar Mode Water decrease from ...

L. D. Talley; M. S. McCartney

1982-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

On Thermally Direct Circulations in Moist Atmospheres  

Science Conference Proceedings (OSTI)

An expression is derived for the critical horizontal gradient of subcloud-layer ?e in radiative-convective equilibrium, sufficient for the onset of thermally direct, zonally symmetric circulations. This corresponds to zero absolute vorticity at ...

Kerry A. Emanuel

1995-05-01T23:59:59.000Z

362

On Thermally Forced Circulations over Heated Terrain  

Science Conference Proceedings (OSTI)

A combination of analytical and numerical models is used to gain insight into the dynamics of thermally forced circulations over diurnally heated terrain. Solutions are obtained for two-layer flows (representing the boundary layer and the ...

Daniel J. Kirshbaum

2013-06-01T23:59:59.000Z

363

Thermally Driven Circulations in Small Oceanic Basins  

Science Conference Proceedings (OSTI)

A linear, steady model of the circulation of a small (f plane) oceanic basin driven by heating or cooling at the surface is considered in order to examine the partition of upwelling (heating) or downwelling (cooling) between the basin's interior ...

Joseph Pedlosky

2003-11-01T23:59:59.000Z

364

The Autonomous Lagrangian Circulation Explorer (ALACE)  

Science Conference Proceedings (OSTI)

The autonomous Lagrangian circulation explorer (ALACE) is a subsurface float that cycles vertically from a depth where it is neutrally buoyant to the surface where it is located by, and relays data to, System Argos satellites. ALACEs are intended ...

R. E. Davis; L. A. Regier; J. Dufour; D. C. Webb

1992-06-01T23:59:59.000Z

365

Snow Hydrology in a General Circulation Model  

Science Conference Proceedings (OSTI)

A snow hydrology has been implemented in an atmospheric general circulation model (GCM). The snow hydrology consists of parameterizations of snowfall and snow cover fraction, a prognostic calculation of snow temperature, and a model of the snow ...

Susan Marshall; John O. Roads; Gary Glatzmaier

1994-08-01T23:59:59.000Z

366

South China Sea Isopycnal-Surface Circulation  

Science Conference Proceedings (OSTI)

This paper investigates the seasonal variabilities of the South China Sea isopycnal-surface circulations and of the Kuroshio intrusion through the Luzon Strait using the U.S. Navys climatological temperature and salinity dataset (public domain) ...

Peter C. Chu; Rongfeng Li

2000-09-01T23:59:59.000Z

367

Significance of sinusoids for myocardial blood circulation  

Science Conference Proceedings (OSTI)

As the myocardial capillaries drain tassel-like into the peripheral end of sinusoids, the venous system of the myocardium begins in the sinusoids and plays an important role in the regulation of myocardial circulation. The sinusoids dilate in response ...

N. Djavakhishvili

1997-01-01T23:59:59.000Z

368

Mixed Layer Deepening Due to Langmuir Circulation  

Science Conference Proceedings (OSTI)

The interaction between wind-driven Langmuir circulation and preexisting stratification is examined in order to elucidate its role in the deepening of the ocean surface mixed layer. For linear stratification, a numerical model suggests that ...

Ming Li; Chris Garrett

1997-01-01T23:59:59.000Z

369

A Spontaneously Generated Tropical Atmospheric General Circulation  

Science Conference Proceedings (OSTI)

A series of idealized atmospheric general circulation model (AGCM) experiments are presented. These experiments examine whether and how atmospheric deep moist convection, in the absence of meridional gradients in external forcing, interacts with ...

Ben P. Kirtman; Edwin K. Schneider

2000-07-01T23:59:59.000Z

370

The Bjerknes' Circulation Theorem: A Historical Perspective  

Science Conference Proceedings (OSTI)

Two lines of thinking concerning fluid rotationusing either vorticity or circulationemerged from the nineteenth-century work of Helmholtz and Thomson (Lord Kelvin), respectively. Vilhelm Bjerknes introduced an extension of Kelvin's ideas on ...

Alan J. Thorpe; Hans Volkert; Micha?J. Ziemianski

2003-04-01T23:59:59.000Z

371

Interannual Variations in the Southern Hemisphere Circulation  

Science Conference Proceedings (OSTI)

An analysis has been made of variations in the atmospheric circulation with periods of more than 50 days occurring in the Southern Hemisphere between 1980 and 1986, using analyses produced by the European Centre for Medium Range Weather Forecasts ...

John W. Kidson

1988-12-01T23:59:59.000Z

372

Atlantic Dominance of the Meridional Overturning Circulation  

Science Conference Proceedings (OSTI)

North Atlantic (NA) deep-water formation and the resulting Atlantic meridional overturning cell is generally regarded as the primary feature of the global overturning circulation and is believed to be a result of the geometry of the continents. ...

A. M. de Boer; J. R. Toggweiler; D. M. Sigman

2008-02-01T23:59:59.000Z

373

On the Climatic Impact of Ocean Circulation  

Science Conference Proceedings (OSTI)

Integrations of coupled climate models with mixed-layer and fixed-current ocean components are used to explore the climatic response to varying magnitudes of ocean circulation. Four mixed-layer ocean experiments without ocean heat transports are ...

Michael Winton

2003-09-01T23:59:59.000Z

374

The Influence of Coastal Shape on Winter Mesoscale Air-Sea Interaction  

Science Conference Proceedings (OSTI)

In the case of cold air outbreaks, the combination of the coastal shape and the sea surface temperature (SST) pattern is shown to have a profound effect in establishing a low level mesoscale atmospheric circulation as a result of differential ...

David Atlas; Shu-Hsien Chou; William P. Byerly

1983-02-01T23:59:59.000Z

375

Blind benchmark predictions of the NACOK air ingress tests using the CFD code FLUENT  

E-Print Network (OSTI)

The JAERI and NACOK experiments examine the combined effects of natural convection during an air ingress event: diffusion, onset of natural circulation, graphite oxidation and multicomponent chemical reactions. MIT has ...

Brudieu, Marie-Anne V

2007-01-01T23:59:59.000Z

376

An Evaluation of AirSea Flux Products for ENSO Simulation and Prediction  

Science Conference Proceedings (OSTI)

This paper presents a quantitative methodology for evaluating airsea fluxes related to ENSO from different atmospheric products. A statistical model of the fluxes from each atmospheric product is coupled to an ocean general circulation model (...

M. J. Harrison; A. Rosati; B. J. Soden; E. Galanti; E. Tziperman

2002-03-01T23:59:59.000Z

377

South Atlantic Variability Arising from AirSea Coupling: Local Mechanisms and TropicalSubtropical Interactions  

Science Conference Proceedings (OSTI)

Interannual variability in the southern and equatorial Atlantic is investigated using an atmospheric general circulation model (AGCM) coupled to a slab ocean model (SOM) in the Atlantic in order to isolate features of airsea interactions ...

Sylwia Trzaska; Andrew W. Robertson; John D. Farrara; Carlos R. Mechoso

2007-07-01T23:59:59.000Z

378

A Coupled AirSea Mesoscale Model: Experiments in Atmospheric Sensitivity to Marine Roughness  

Science Conference Proceedings (OSTI)

A coupled airsea numerical model comprising a mesoscale atmospheric model, a marine circulation model, and a surface wave model is presented. The coupled model is tested through simulations of an event of frontal passage through the Lake Erie ...

Jordan G. Powers; Mark T. Stoelinga

2000-01-01T23:59:59.000Z

379

Documentation of Calculation Methodology, Input data, and Infrastructure for the Home Energy Saver Web Site  

E-Print Network (OSTI)

heat pump (heating) Electric baseboard heater Gas boilerOil boiler Central air conditioner Room air conditioner18 3.1.6.1 Boiler Pipe

2005-01-01T23:59:59.000Z

380

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network (OSTI)

StalledAirConditionerCompressors,IEEETransactionsonStalled AirConditionerCompressors,IEEETransactionsonsuggested thatthecompressortorquemaynotbeconstant.

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Federal Energy Management Program: Covered Product Category:...  

NLE Websites -- All DOE Office Websites (Extended Search)

Residential Central Air Conditioners to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Residential Central Air Conditioners on Facebook Tweet...

382

Federal Energy Management Program: Energy Cost Calculator for...  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Unitary Air Conditioner (Rooftops) to someone by E-mail Share Federal Energy Management Program: Energy Cost Calculator for Commercial Unitary Air Conditioner (Rooftops)...

383

Life-Cycle Cost and Payback Period Analysis for Commercial Unitary...  

NLE Websites -- All DOE Office Websites (Extended Search)

and Payback Period Analysis for Commercial Unitary Air Conditioners Title Life-Cycle Cost and Payback Period Analysis for Commercial Unitary Air Conditioners Publication Type...

384

ComEd, Nicor Gas, Peoples Gas & North Shore Gas - Bonus Rebate...  

Open Energy Info (EERE)

Rebates Central Air Conditioner Unit 14 SEER or above: 350 Central Air Conditioner Unit Energy Star rated: 500 Nicor Gas, Peoples Gas & North Shore Gas Furnace: 200 - 500...

385

--No Title--  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

water cooled air conditioner for the purpose of cooling analytical equipment and computers. Water Cooled Air Conditioner, D-1169 Savannah River Site Aiken South Carolina...

386

Building America Top Innovations Hall of Fame Profile … Outside Air Ventilation Controller  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

partner Davis Energy partner Davis Energy Group worked with Monley Cronin Construction to build 100 energy-efficient homes in Woodland, CA, with night- cooling ventilation systems. BUILDING AMERICA TOP INNOVATIONS HALL OF FAME PROFILE INNOVATIONS CATEGORY: 1. Advanced Technologies and Practices 1.3 Assured Health, Safety, and Durability Outside Air Ventilation Controller Building America researchers developed technologies to harness the natural day-night temperature swings in the U.S. Southwest to cut cooling energy peak demand with no compromise in comfort. Building America research has shown that, in dry climates, the use of ventilation cooling can significantly reduce, delay, or completely eliminate air conditioner operation resulting in both energy savings and reduction of peak demand

387

Cascade Reverse Osmosis Air Conditioning System: Cascade Reverse Osmosis and the Absorption Osmosis Cycle  

SciTech Connect

BEETIT Project: Battelle is developing a new air conditioning system that uses a cascade reverse osmosis (RO)-based absorption cycle. Analyses show that this new cycle can be as much as 60% more efficient than vapor compression, which is used in 90% of air conditioners. Traditional vapor-compression systems use polluting liquids for a cooling effect. Absorption cycles use benign refrigerants such as water, which is absorbed in a salt solution and pumped as liquidreplacing compression of vapor. The refrigerant is subsequently separated from absorbing salt using heat for re-use in the cooling cycle. Battelle is replacing thermal separation of refrigerant with a more efficient reverse osmosis process. Research has shown that the cycle is possible, but further investment will be needed to reduce the number of cascade reverse osmosis stages and therefore cost.

None

2010-09-01T23:59:59.000Z

388

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

E-Print Network (OSTI)

was used to forecast electricity prices into the future (Case forecasts residential electricity prices to decline to

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-01-01T23:59:59.000Z

389

Loading capability of HVDC transformer bushings with restricted oil circulation for use in HVDC valve halls  

Science Conference Proceedings (OSTI)

The loading capability of a 500 kV HVDC transformer bushing is calculated with some unusual conditions: the internal oil circulation in the bushing is blocked at the flange level and the ambient air temperature is raised to 60 C. The theoretical model was verified with a full-scale heat run test on a 7.8 m long bushing. A 220 m[sup 3] insulated test chamber was required to enclose the test set-up.

Johansson, L.; Magnuson, B. (ABB Components AB, Ludvika (Sweden)); Riffon, P. (Hydro-Quebec, Montreal, Quebec (Canada))

1993-07-01T23:59:59.000Z

390

Air Resources: Prevention and Control of Air Contamination and Air  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Resources: Prevention and Control of Air Contamination and Air Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York) Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York) < Back Eligibility Agricultural Fuel Distributor Industrial Institutional Investor-Owned Utility Local Government Multi-Family Residential Municipal/Public Utility Nonprofit Rural Electric Cooperative Schools State/Provincial Govt Transportation Tribal Government Utility Program Info State New York Program Type Environmental Regulations Provider NY Department of Environmental Conservation These regulations establish emissions limits and permitting and operational

391

The Effects of Thermohaline Circulation on Wind-Driven Circulation in the South China Sea  

Science Conference Proceedings (OSTI)

The dynamic influence of thermohaline circulation on wind-driven circulation in the South China Sea (SCS) is studied using a simple reduced gravity model, in which the upwelling driven by mixing in the abyssal ocean is treated in terms of an ...

Guihua Wang; Rui Xin Huang; Jilan Su; Dake Chen

2012-12-01T23:59:59.000Z

392

Continuous Circulation System: a new enabling technology  

E-Print Network (OSTI)

Wellbore problems have existed since the very first oil well was drilled. These problems have cost the oil industry millions of dollars because they lead to substantial loss of valuable rig time, or even loss of the well. Some of these problems are caused by the interruption of the drilling-fluid circulation. This interruption normally occurs when making drillpipe connections. Interruption of circulation causes wellbore problems like ballooning of the well, gelation of drilling mud, and settling of drilled cuttings. It also causes some operating problems in underbalanced drilling. A new technology in drilling has been introduced through a joint industry project to overcome problems caused by interruption of circulation. This technology is the Continuous Circulation System (CCS). The CCS is capable of achieving continuous circulation while making/breaking drillpipe connections. This research highlights the significance of the new technology by investigating the problems caused by interruption of circulation. It presents some potential operational problems regarding the new system and discusses the possibility to achieve continuous drilling. The economics of the new technology is presented. This study found that the CCS would prevent significant wellbore problems from occurring, hence saving valuable rig time and money. It also showed that CCS would be a valuable addition to the equipment used in underbalanced drilling. Continuous drilling while making connections can be achieved using mud-motors. On the other hand, it is not feasible through rotation of the drillstring under the current technology. Finally, the suitable marketing strategy for this phase of the new technology is to offer it for lease rather than for sale.

Kenawy, Walid F.

2002-01-01T23:59:59.000Z

393

Air-Source Heat Pump Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air-Source Heat Pump Basics Air-Source Heat Pump Basics Air-Source Heat Pump Basics August 19, 2013 - 11:03am Addthis Air-source heat pumps transfer heat between the inside of a building and the outside air. How Air-Source Heat Pumps Work This diagram of a split-system heat pump heating cycle shows refrigerant circulating through a closed loop that passes through the wall of a house. Inside the house the refrigerant winds through indoor coils, with a fan blowing across them, and outside the house is another fan and another set of coils, the outdoor coils. A compressor is between the coils on one half of the loop, and an expansion valve is between the coils on the other half. The diagram is explained in the caption. In heating mode, an air-source heat pump evaporates a refrigerant in the outdoor coil; as the liquid evaporates it pulls

394

State-of-the-Art in Residential and Small Commercial Air HandlerPerformance  

SciTech Connect

Although furnaces, air conditioners, and heat pumps have become significantly more efficient over the last couple of decades, residential air handlers have typical efficiencies of only 10% to 15% due to poor electric motor and aerodynamic performance. These low efficiencies indicate that there is significant room for improvement of air handler fans. The other 85-90% of the electricity used by air handlers is manifested as heat. This extra heat reduces air conditioning cooling and dehumidification performance and effectively acts as fuel switching for fossil fueled furnaces. For electric furnaces, this heat substitutes directly for the electric resistance heating elements. For heat pumps, this heat substitutes for compressor-based high COP heating and effectively reduces the COP of the heat pump. Using a combination of field observations and engineering judgment they can assemble a list of the problems that lead to low air handler efficiency and potential solutions to these problems, as shown. None of the problems require exotic or complex solutions and there are no technological barriers to adopting them. Some of the solutions are simple equipment swaps (using better electric motors), others require changes to the way the components are built (tighter tolerances) and other relate to HVAC equipment design (not putting large fans in small cabinets).

Walker, Iain S.

2005-03-01T23:59:59.000Z

395

Statistical mechanics and ocean circulation Rick Salmon  

E-Print Network (OSTI)

Statistical mechanics and ocean circulation Rick Salmon Scripps Institution of Oceanography, UCSD equilibrium statistical mechanics based upon the conservation of energy and potential enstrophy to the mass. The equilibrium state resembles the buoyancy structure actually observed. Key words: statistical mechanics, ocean

Salmon, Rick

396

Standing Eddies in the Meridional Overturning Circulation  

Science Conference Proceedings (OSTI)

The role of standing eddies for the meridional overturning circulation (MOC) is discussed. The time-mean isopycnal meridional streamfunction is decomposed into a time- and zonal-mean part, a standing-eddy part, and a transient-eddy part. It turns ...

Jan Viebahn; Carsten Eden

2012-09-01T23:59:59.000Z

397

Rotating Hydraulics and Upstream Basin Circulation  

Science Conference Proceedings (OSTI)

The flow in a source-fed f-plane basin drained through a strait is explored using a single-layer (reduced gravity) shallow-water numerical model that resolves the hydraulic flow within the strait. The steady upstream basin circulation is found to ...

Karl R. Helfrich; Lawrence J. Pratt

2003-08-01T23:59:59.000Z

398

Ocean Circulation Kinetic Energy: Reservoirs, Sources,  

E-Print Network (OSTI)

. The coupling of the generation of different energy forms in the dynamics (in either balanced or wave motions are almost nonexistent in the ocean. www.annualreviews.org · Ocean Circulation Kinetic Energy 255 Annu.Rev.Fluid processes? Are the seemingly different dynamical ranges coupled? 2. THE OCEANIC ENERGY BUDGET We begin

Ferrari, Raffaele

399

Transport Asymmetry in Skewed Convective Circulations  

Science Conference Proceedings (OSTI)

Two simple kinematical models are used to describe the asymmetry in bottom-up and top-down diffusion in the convective boundary layer. Both models resolve the mean circulation with narrow updrafts and wider downdrafts but differ in the treatment ...

Ulrich Schumann

1993-01-01T23:59:59.000Z

400

DEVELOPMENT OF PRESSURIZED CIRCULATING FLUIDIZED BED PARTIAL GASIFICATION MODULE (PGM)  

SciTech Connect

Foster Wheeler Development Corporation is working under DOE contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% while producing near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The unique aspect of the process is that it utilizes a pressurized circulating fluidized bed partial gasifier and does not attempt to consume the coal in a single step. To convert all the coal to syngas in a single step requires extremely high temperatures ({approx}2500 to 2800F) that melt and vaporize the coal and essentially drive all coal ash contaminants into the syngas. Since these contaminants can be corrosive to power generating equipment, the syngas must be cooled to near room temperature to enable a series of chemical processes to clean the syngas. Foster Wheeler's process operates at much lower temperatures that control/minimize the release of contaminants; this eliminates/minimizes the need for the expensive, complicated syngas heat exchangers and chemical cleanup systems typical of high temperature gasification. By performing the gasification in a circulating bed, a significant amount of syngas can still be produced despite the reduced temperature and the circulating bed allows easy scale up to large size plants. Rather than air, it can also operate with oxygen to facilitate sequestration of stack gas carbon dioxide gases for a 100% reduction in greenhouse gas emissions. The amount of syngas and char produced by the PGM can be tailored to fit the production objectives of the overall plant, i.e., power generation, clean liquid fuel production, chemicals production, etc. Hence, PGM is a robust building block that offers all the advantages of coal gasification but in a more user friendly form; it is also fuel flexible in that it can use alternative fuels such as biomass, sewerage sludge, etc. The PGM consists of a pressurized circulating fluidized bed (PCFB) reactor together with a recycle cyclone and a particulate removing barrier filter. Coal, air, steam, and possibly sand are fed to the bottom of the PCFB reactor and establish a relatively dense bed of coal/char in the bottom section. As these constituents react, a hot syngas is produced which conveys the solids residue vertically up through the reactor and into the recycle cyclone. Solids elutriated from the dense bed and contained in the syngas are collected in the cyclone and drain via a dipleg back to the dense bed at the bottom of the PCFB reactor. This recycle loop of hot solids acts as a thermal flywheel and promotes efficient solid-gas chemical reaction.

Unknown

2001-07-10T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Regional Climates in the GISS Global Circulation Model: Synoptic-Scale Circulation  

Science Conference Proceedings (OSTI)

Model simulations of global climate change are seen as an essential component of any program at understanding human impact on the global environment. A major weakness of current general circulation models (GCMs), however, is their perceived ...

B. Hewitson; R. G. Crane

1992-09-01T23:59:59.000Z

402

Air Pollution (Illinois)  

Energy.gov (U.S. Department of Energy (DOE))

This article states regulations for monitoring air pollution, methods for permit applications, emission limitations for pollutants and air quality standards.

403

DEVELOPMENT OF PRESSURIZED CIRCULATING FLUIDIZED BED PARTIAL GASIFICATION MODULE (PGM)  

SciTech Connect

Foster Wheeler Development Corporation is working under DOE contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% while producing near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The unique aspect of the process is that it utilizes a pressurized circulating fluidized bed partial gasifier and does not attempt to consume the coal in a single step. To convert all the coal to syngas in a single step requires extremely high temperatures ({approx}2500 to 2800 F) that melt and vaporize the coal and essentially drive all coal ash contaminants into the syngas. Since these contaminants can be corrosive to power generating equipment, the syngas must be cooled to near room temperature to enable a series of chemical processes to clean the syngas. Foster Wheeler's process operates at much lower temperatures that control/minimize the release of contaminants; this eliminates/minimizes the need for the expensive, complicated syngas heat exchangers and chemical cleanup systems typical of high temperature gasification. By performing the gasification in a circulating bed, a significant amount of syngas can still be produced despite the reduced temperature and the circulating bed allows easy scale up to large size plants. Rather than air, it can also operate with oxygen to facilitate sequestration of stack gas carbon dioxide gases for a 100% reduction in greenhouse gas emissions.

Unknown

2002-03-29T23:59:59.000Z

404

Optimal Surface Salinity Perturbations Influencing the Thermohaline Circulation  

Science Conference Proceedings (OSTI)

Optimal surface salinity perturbations influencing the meridional overturning circulation maximum are exhibited and interpreted on a stable steady state of a 2D latitudedepth ocean thermohaline circulation model. Despite the stability of the ...

Florian Svellec; Mahdi Ben Jelloul; Thierry Huck

2007-12-01T23:59:59.000Z

405

Optimal excitation of interannual atlantic meridional overturning circulation variability  

E-Print Network (OSTI)

The optimal excitation of Atlantic meridional overturning circulation (MOC) anomalies is investigated in an ocean general circulation model with an idealized configuration. The optimal three-dimensional spatial structure ...

Zanna, Laure

406

Multiple Oscillatory Modes of the Global Ocean Circulation  

Science Conference Proceedings (OSTI)

For the first time, the (linear) stability of the global ocean circulation has been determined explicitly. In a low-resolution general circulation model, a steady state is computed directly by solving the elliptic boundary value problem. The ...

Wilbert Weijer; Henk A. Dijkstra

2003-11-01T23:59:59.000Z

407

Mixing and Energetics of the Oceanic Thermohaline Circulation  

Science Conference Proceedings (OSTI)

Using an idealized tube model and scaling analysis, the physics supporting the oceanic thermohaline circulation is examined. Thermal circulation in the tube model can be classified into two categories. When the cooling source is at a level higher ...

Rui Xin Huang

1999-04-01T23:59:59.000Z

408

Quasi-Periodic Oscillations in a Symmetric General Circulation Model  

Science Conference Proceedings (OSTI)

Long lime integrations with a symmetric version of the CLAS Climate Model with hydrology have shown that the Hadley circulation has well defined strong and weak episodes. This oscillation of the Hadley circulation seems to occur in two dominant ...

B. N. Gyoswami; J. Shukla

1984-01-01T23:59:59.000Z

409

Effects of Penetrative Radiation on the Upper Tropical Ocean Circulation  

Science Conference Proceedings (OSTI)

The effects of penetrative radiation on the upper tropical ocean circulation have been investigated with an ocean general circulation model (OGCM) with attenuation depths derived from remotely sensed ocean color data. The OGCM is a reduced ...

Raghu Murtugudde; James Beauchamp; Charles R. McClain; Marlon Lewis; Antonio J. Busalacchi

2002-03-01T23:59:59.000Z

410

Energetics of a Symmetric Circulation Including Momentum Constraints  

Science Conference Proceedings (OSTI)

A theory of available potential energy (APE) for symmetric circulations, which includes momentum constraints, is presented. The theory is a generalization of the classical theory of APE, which includes only thermal constraints on the circulation. ...

Sorin Codoban; Theodore G. Shepherd

2003-08-01T23:59:59.000Z

411

Interhemispheric Thermohaline Circulation in a Coupled Box Model  

Science Conference Proceedings (OSTI)

The interhemispheric thermohaline circulation is examined using Rooths three-box ocean model, whereby overturning strength is parameterized from density differences between high-latitude boxes. Recent results with general circulation models ...

Jeffery R. Scott; Jochem Marotzke; Peter H. Stone

1999-03-01T23:59:59.000Z

412

Seasonal Characteristics of Circulation in the Southeastern Tropical Indian Ocean  

Science Conference Proceedings (OSTI)

The circulation in the southeastern tropical Indian Ocean is studied using historical temperature and salinity data. A southward shift of the subtropical gyre at increasing depth dominates the structure of the annual mean circulation. Near the ...

Tangdong Qu; Gary Meyers

2005-02-01T23:59:59.000Z

413

Hadley Circulation Response to Orbital Precession. Part I: Aquaplanets  

Science Conference Proceedings (OSTI)

The response of the monsoonal and annual-mean Hadley circulation to orbital precession is examined in an idealized atmospheric general circulation model with an aquaplanet slab-ocean lower boundary. Contrary to expectations, the simulated ...

Timothy M. Merlis; Tapio Schneider; Simona Bordoni; Ian Eisenman

2013-02-01T23:59:59.000Z

414

Hadley Circulation Response to Orbital Precession. Part II: Subtropical Continent  

Science Conference Proceedings (OSTI)

The response of the monsoonal and annual-mean Hadley circulation to orbital precession is examined in an idealized atmospheric general circulation model with a simplified representation of land surface processes in subtropical latitudes. When ...

Timothy M. Merlis; Tapio Schneider; Simona Bordoni; Ian Eisenman

2013-02-01T23:59:59.000Z

415

Constraining North Atlantic circulation with transient tracer observations  

E-Print Network (OSTI)

The capability of transient tracers to constrain the ocean circulation in the North Atlantic is explored. Study of an idealized tracer shows that inferences of circulation properties from transient state distributions are ...

Li, Xingwen, 1968-

2003-01-01T23:59:59.000Z

416

Simulations of Persistent North Pacific Circulation Anomalies and Interhemispheric Teleconnections  

Science Conference Proceedings (OSTI)

Evidence is presented from a composite analysis of a 14-year general circulation model simulation, that persistent North Pacific (PNP) circulation anomalies during boreal winter are part of a larger-scale meridional development extending into the ...

R. W. Higgins; S. D. Schubert

1996-01-01T23:59:59.000Z

417

Boundary Layer Dynamics and Cross-Equatorial Hadley Circulation  

Science Conference Proceedings (OSTI)

The behavior of the Hadley circulation is analyzed in the context of an idealized axisymmetric atmosphere. It is argued that the cross-equatorial Hadley circulation exhibits two different regimes depending on the depth of the planetary boundary ...

Olivier Pauluis

2004-05-01T23:59:59.000Z

418

The Energetics of Global Thermohaline Circulation and Its Wind Enhancement  

Science Conference Proceedings (OSTI)

The energy budget of global thermohaline circulation (THC) is numerically investigated using an ocean general circulation model (OGCM) under a realistic configuration. Earlier studies just discuss a globally integrated energy budget. This study ...

L. Shogo Urakawa; Hiroyasu Hasumi

2009-07-01T23:59:59.000Z

419

Memorandum To: GENERAL COUNSEL, DEPARTMENT OF ENERGY (DOE) From: JONATHAN MELCHI, HEATING, AIR-CONDITIONING AND REFRIGERATION  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

To: GENERAL COUNSEL, DEPARTMENT OF ENERGY (DOE) To: GENERAL COUNSEL, DEPARTMENT OF ENERGY (DOE) From: JONATHAN MELCHI, HEATING, AIR-CONDITIONING AND REFRIGERATION DISTRIBUTORS INTERNATIONAL (HARDI) Date: 1/12/2012 Subject: EX PARTE COMMUNICATION MEMO DOE ATTENDEES: Ashley Armstrong, John Cymbalsky, David Case, Laura Barhydt HARDI ATTENDEES: Talbot Gee, Jonathan Melchi AREAS OF DISCUSSION: DOE Framework Document and Stakeholder Meeting regarding the Enforcement of the updated Energy Conservation Standards for Air Conditioners, Furnaces and Heat Pumps. The meeting took place on Thursday January 5 th , 2012 from 2pm to 3-pm. The following topics were discussed. 1.) Sell-Through. HARDI asked for clarification on the DOE's notation on the Framework Document

420

Dynamical constraints on monsoon circulations R. Alan Plumb  

E-Print Network (OSTI)

Dynamical constraints on monsoon circulations R. Alan Plumb Dept. of Earth, Atmospheric and Planetary Sciences Massachusetts Institute of Technology August 17, 2005 Abstract Monsoon circulations on monsoon circulations, a comprehensive theory of their dynamics is still lacking. It is clear that, given

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Fuzzy expert system for solving lost circulation problem  

Science Conference Proceedings (OSTI)

Lost circulation is the most common problem encountered while drilling oil wells. This paper describes a distributed fuzzy expert system, called Smart-Drill, aimed in helping petroleum engineers to diagnose and solve lost circulation problems. To represent ... Keywords: Finite ordinal scales, Fuzzy algebra, Fuzzy expert system, Knowledge representation, Lost circulation problem, Multi-sets, Oil well drilling

Leonid Sheremetov; Ildar Batyrshin; Denis Filatov; Jorge Martinez; Hector Rodriguez

2008-01-01T23:59:59.000Z

422

The Response of an Ocean General Circulation Model to Surface Wind Stress Produced by an Atmospheric General Circulation Model  

Science Conference Proceedings (OSTI)

Two surface wind stress datasets for 197991, one based on observations and the other from an integration of the COLA atmospheric general circulation model (AGCM) with prescribed SST, are used to drive the GFDL ocean general circulation model. ...

Bohua Huang; Edwin K. Schneider

1995-10-01T23:59:59.000Z

423

Effects of Saturated and Dry Land Surfaces on the Tropical Circulation and Precipitation in a General Circulation Model  

Science Conference Proceedings (OSTI)

A comprehensive rhomboidal-15 general circulation model with idealized boundary conditions is used to investigate the effects of interactions between the tropical circulation and continental climate on the precipitation distribution. Sea surface ...

Kerry H. Cook; Anand Gnanadesikan

1991-09-01T23:59:59.000Z

424

Influence of Land Surface Roughness on Atmospheric Circulation and Precipitation: A Sensitivity Study with a General Circulation Model  

Science Conference Proceedings (OSTI)

The influence of land surface roughness on the large scale atmospheric circulation and rainfall was examined by comparing three sets of simulations made with a general circulation model in which the land surface roughness length, z0, was reduced ...

Y. C. Sud; J. Shukla; Y. Mintz

1988-09-01T23:59:59.000Z

425

Cluster Dynamics in a Circulating Fluidized Bed  

Science Conference Proceedings (OSTI)

A common hydrodynamic feature in industrial scale circulating fluidized beds is the presence of clusters. The continuous formation and destruction of clusters strongly influences particle hold-up, pressure drop, heat transfer at the wall, and mixing. In this paper fiber optic data is analyzed using discrete wavelet analysis to characterize the dynamic behavior of clusters. Five radial positions at three different axial locations under five different operating were analyzed using discrete wavelets. Results are summarized with respect to cluster size and frequency.

Guenther, C.P.; Breault, R.W.

2006-11-01T23:59:59.000Z

426

NUCLA Circulating Atmospheric Fluidized Bed Demonstration Project  

Science Conference Proceedings (OSTI)

The objective of this DOE Cooperative Agreement is to conduct a cost-shared clean coal technology project to demonstrate the feasibility of circulating fluidized bed combustion technology and to evaluate economic, environmental, and operational benefits of CFB steam generators on a utility scale. At the conclusion of the Phase 2 program, testing related to satisfying these objectives was completed. Data analysis and reporting are scheduled for completion by October 1991. (VC)

Not Available

1992-02-01T23:59:59.000Z

427

Reducing mode circulating fluid bed combustion  

DOE Patents (OSTI)

A method for combustion of sulfur-containing fuel in a circulating fluid bed combustion system wherein the fuel is burned in a primary combustion zone under reducing conditions and sulfur captured as alkaline sulfide. The reducing gas formed is oxidized to combustion gas which is then separated from solids containing alkaline sulfide. The separated solids are then oxidized and recycled to the primary combustion zone.

Lin, Yung-Yi (Katy, TX); Sadhukhan, Pasupati (Katy, TX); Fraley, Lowell D. (Sugarland, TX); Hsiao, Keh-Hsien (Houston, TX)

1986-01-01T23:59:59.000Z

428

Global circulation as the main source of cloud activity on Titan  

E-Print Network (OSTI)

Clouds on Titan result from the condensation of methane and ethane and, as on other planets, are primarily structured by circulation of the atmosphere. At present, cloud activity mainly occurs in the southern (summer) hemisphere, arising near the pole and at mid-latitudes from cumulus updrafts triggered by surface heating and/or local methane sources, and at the north (winter) pole, resulting from the subsidence and condensation of ethane-rich air into the colder troposphere. General circulation models predict that this distribution should change with the seasons on a 15-year timescale, and that clouds should develop under certain circumstances at temperate latitudes (~40\\degree) in the winter hemisphere. The models, however, have hitherto been poorly constrained and their long-term predictions have not yet been observationally verified. Here we report that the global spatial cloud coverage on Titan is in general agreement with the models, confirming that cloud activity is mainly controlled by the global circ...

Rodriguez, Sbastien; Rannou, Pascal; Tobie, Gabriel; Baines, Kevin H; Barnes, Jason W; Griffith, Caitlin A; Hirtzig, Mathieu; Pitman, Karly M; Sotin, Christophe; Brown, Robert H; Buratti, Bonnie J; Clark, Roger N; Nicholson, Phil D; 10.1038/NATURE08014

2009-01-01T23:59:59.000Z

429

Promoting emerging energy-efficiency technologies and practices by utilities in a restructured energy industry: A report from California  

E-Print Network (OSTI)

condenser cooling Optimized air conditioners Indirect/direct evaporative coolers Daylighting tools and controls Commercial

Vine, Edward L.

2000-01-01T23:59:59.000Z

430

Effects of cumulus convection on the simulated monsoon circulation in a general circulation model  

SciTech Connect

The effect of cumulus convection on the Asian summer monsoon circulation is investigated, using a general circulation model. Two simulations for the summer months (June, July, and August) are performed, one parameterizing convection using a mass flux scheme and the other without convective parameterization. The results show that convection has significant effects on the monsoon circulation and its associated precipitation. In the simulation with the mass flux convective parameterization, precipitation in the western Pacific is decreased, together with a decrease in surface evaporation and wind speed. In the indian monsoon region it is almost the opposite. Comparison with a simulation using moist convective adjustment to parameterize convection shows that the monsoon circulation and precipitation distribution in the no-convection simulation are very similar to those in the simulation with moist convective adjustment. The difference in the large-scale circulation with and without convective parameterization is interpreted in terms of convective stabilization of the atmosphere by convection, using dry and moist static energy budgets. It is shown that weakening of the low-level convergence in the western Pacific in the simulation with convection is closely associated with the stabilization of the atmosphere by convection, mostly through drying of the lower troposphere; changes in low-level convergence lead to changes in precipitation. The precipitation increase in the Indian monsoon can be explained similarly. 29 refs., 12 figs.

Zhang, Guang Jun (Univ. of California, San Diego, La Jolla, CA (United States))

1994-09-01T23:59:59.000Z

431

Air Leakage of Furnaces and Air Handlers  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Leakage of Furnaces and Air Handlers Air Leakage of Furnaces and Air Handlers Title Air Leakage of Furnaces and Air Handlers Publication Type Journal Article LBNL Report Number LBNL-5553E Year of Publication 2010 Authors Walker, Iain S., Mile Lubliner, Darryl J. Dickerhoff, and William W. Delp Journal 2010 ACEEE Summer Study on Energy Efficiency in Buildings The Climate for efficiency is now Date Published 08/2010 Abstract In recent years, great strides have been made in reducing air leakage in residential and to a lesser extent small commercial forced air duct systems. Several authorities have introduced low leakage limits for thermal distribution systems; for example, the State of California Energy Code for Buildings gives credit for systems that leak less than 6% of the total air flow at 25 Pa.

432

Analysis of Potential Energy Saving and CO2 Emission Reduction of Home Appliances and Commercial Equipments in China  

E-Print Network (OSTI)

CL COMMERCIAL REFRIGERATION STANDBY External power suppliesTV, refrigerator, fans, standby, air conditioner, electricConditioner Diff 3.59E-04 The standby power consumption of

Zhou, Nan

2011-01-01T23:59:59.000Z

433

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 2, Fluorescent lamp ballasts, television sets, room air conditioners, and kitchen ranges and ovens  

SciTech Connect

This document is divided into ``volumes`` B through E, dealing with individual classes of consumer products. Chapters in each present engineering analysis, base case forecasts, projected national impacts of standards, life-cycle costs and payback periods, impacts on manufacturers, impacts of standards on electric utilities, and environmental effects. Supporting appendices are included.

Not Available

1993-11-01T23:59:59.000Z

434

A Two-Box Model of a Zonal Atmospheric Circulation in the Tropics  

Science Conference Proceedings (OSTI)

A simple fixed-SST model of a zonal circulation in the tropical atmosphere has been developed that has separate boxes for the ascending and descending branches of the atmospheric circulation. This circulation resembles the Walker circulation. ...

Michael A. Kelly; David A. Randall

2001-10-01T23:59:59.000Z

435

Metal-Air Batteries  

Science Conference Proceedings (OSTI)

Metal-air batteries have much higher specific energies than most currently available primary and rechargeable batteries. Recent advances in electrode materials and electrolytes, as well as new designs on metal-air batteries, have attracted intensive effort in recent years, especially in the development of lithium-air batteries. The general principle in metal-air batteries will be reviewed in this chapter. The materials, preparation methods, and performances of metal-air batteries will be discussed. Two main metal-air batteries, Zn-air and Li-air batteries will be discussed in detail. Other type of metal-air batteries will also be described.

Zhang, Jiguang; Bruce, Peter G.; Zhang, Gregory

2011-08-01T23:59:59.000Z

436

Nucla circulating atmospheric fluidized bed demonstration project  

Science Conference Proceedings (OSTI)

During the fourth quarter of 1990, steady-state performance testing at the Nucla Circulating Fluidized Bed (CFB) resumed under sponsorship of the US Department of Energy. Co-sponsorship of the Demonstration Test Program by the Electric Power Research Institute (EPRI) was completed on June 15, 1990. From October through December, 1990, Colorado-Ute Electric Association (CUEA) completed a total of 23 steady-state performance tests, 4 dynamic tests, and set operating records during November and December as the result of improved unit operating reliability. Highlight events and achievements during this period of operation are presented.

Not Available

1991-01-31T23:59:59.000Z

437

Feasibility of air capture  

E-Print Network (OSTI)

Capturing CO2 from air, referred to as Air Capture, is being proposed as a viable climate change mitigation technology. The two major benefits of air capture, reported in literature, are that it allows us to reduce the ...

Ranjan, Manya

2010-01-01T23:59:59.000Z

438

Air-Source Heat Pump Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Source Heat Pump Basics Source Heat Pump Basics Air-Source Heat Pump Basics August 19, 2013 - 11:03am Addthis Air-source heat pumps transfer heat between the inside of a building and the outside air. How Air-Source Heat Pumps Work This diagram of a split-system heat pump heating cycle shows refrigerant circulating through a closed loop that passes through the wall of a house. Inside the house the refrigerant winds through indoor coils, with a fan blowing across them, and outside the house is another fan and another set of coils, the outdoor coils. A compressor is between the coils on one half of the loop, and an expansion valve is between the coils on the other half. The diagram is explained in the caption. In heating mode, an air-source heat pump evaporates a refrigerant in the outdoor coil; as the liquid evaporates it pulls

439

Primary zone air proportioner  

SciTech Connect

An air proportioner is provided for a liquid hydrocarbon fueled gas turbine of the type which is convertible to oil gas fuel and to coal gas fuel. The turbine includes a shell for enclosing the turbine, an air duct for venting air in said shell to a gasifier, and a fuel injector for injecting gasified fuel into the turbine. The air proportioner comprises a second air duct for venting air from the air duct for mixing with fuel from the gasifier. The air can be directly injected into the gas combustion basket along with the fuel from the injector or premixed with fuel from the gasifier prior to injection by the fuel injector.

Cleary, Edward N. G. (San Diego, CA)

1982-10-12T23:59:59.000Z

440

Air Pollution Control (Indiana)  

Energy.gov (U.S. Department of Energy (DOE))

This legislation establishes the Department of Environmental Management and the Air Pollution Control Board, which are tasked with the prevention, abatement, and control of air pollution by all...

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Hot air drum evaporator. [Patent application  

DOE Patents (OSTI)

An evaporation system for aqueous radioactive waste uses standard 30 and 55 gallon drums. Waste solutions form cascading water sprays as they pass over a number of trays arranged in a vertical stack within a drum. Hot dry air is circulated radially of the drum through the water sprays thereby removing water vapor. The system is encased in concrete to prevent exposure to radioactivity. The use of standard 30 and 55 gallon drums permits an inexpensive compact modular design that is readily disposable, thus eliminating maintenance and radiation build-up problems encountered with conventional evaporation systems.

Black, R.L.

1980-11-12T23:59:59.000Z

442

EIS-0289: JEA Circulating Fluidized Bed Combustor Project | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

289: JEA Circulating Fluidized Bed Combustor Project 289: JEA Circulating Fluidized Bed Combustor Project EIS-0289: JEA Circulating Fluidized Bed Combustor Project SUMMARY This EIS assesses environmental issues associated with constructing and demonstrating a project that would be cost-shared by DOE and JEA (formerly the Jacksonville Electric Authority) under the Clean Coal Technology Program. PUBLIC COMMENT OPPORTUNITIES None available at this time. DOCUMENTS AVAILABLE FOR DOWNLOAD December 7, 2000 EIS-0289: Record of Decision JEA Circulating Fluidized Bed Combustor Project, Jacksonville, Duval County, FL June 1, 2000 EIS-0289: Final Environmental Impact Statement JEA Circulating Fluidized Bed Combustor Project August 1, 1999 EIS-0289: Draft Environmental Impact Statement JEA Circulating Fluidized Bed Combustor

443

Evaluating candidate lost circulation materials for geothermal drilling  

DOE Green Energy (OSTI)

Sandia National Laboratories' Geothermal Technology Development Division is working to advance the state of the art of lost circulation prevention and control. For this purpose, a large-scale lost Circulation Test Facility was designed and built. This paper addresses the evaluation of candidate lost circulation materisl using this facility and also using the recommended practice of API RP 131. Test results from these facilities are compared and discussed for the materials tested.

Loeppke, G.

1986-01-01T23:59:59.000Z

444

AirSea Heat Exchanges Characteristic of a Prominent Midlatitude Oceanic Front in the South Indian Ocean as Simulated in a High-Resolution Coupled GCM  

Science Conference Proceedings (OSTI)

An integration of a high-resolution coupled general circulation model whose ocean component is eddy permitting and thus able to reproduce a sharp gradient in sea surface temperature (SST) is analyzed to investigate airsea heat exchanges ...

Masami Nonaka; Hisashi Nakamura; Bunmei Taguchi; Nobumasa Komori; Akira Kuwano-Yoshida; Koutarou Takaya

2009-12-01T23:59:59.000Z

445

Evaluation of cirrus statistics produced by general circulation...  

NLE Websites -- All DOE Office Websites (Extended Search)

produced by general circulation models using ARM data Hartsock, Daniel University of Utah Mace, Gerald University of Utah Benson, Sally University of Utah Category: Modeling Our...

446

Improvement of Product Quality in Circulating Fluidized Bed ...  

Science Conference Proceedings (OSTI)

Abstract Scope, Until the introduction of Circulating Fluidized Bed (CFB) Calciners by Outotec (formerly Lurgi) in 1961 rotary kilns were the standard technology...

447

Progress in The Lost Circulation Technology Development Program  

DOE Green Energy (OSTI)

Lost circulation is the loss of drilling fluid from the wellbore to fractures or pores in the rock formation. In geothermal drilling, lost circulation is often a serious problem that contributes greatly to the cost of the average geothermal well. The Lost Circulation Technology Development Program is sponsored at Sandia National Laboratories by the US Department of Energy. The goal of the program is to reduce lost circulation costs by 30--50{percent} through the development of mitigation and characterization technology. This paper describes the technical progress made in this program during the period April, 1990--March, 1991. 4 refs., 15 figs., 1 tab.

Glowka, D.A.; Schafer, D.M.; Loeppke, G.E.; Wright, E.K.

1991-01-01T23:59:59.000Z

448

Circulating Fluidized Bed Combustion Boiler Project  

E-Print Network (OSTI)

The project to build a PYROFLOW circulating fluidized bed combustion (FBC) boiler at the BFGoodrich Chemical Plant at Henry, Illinois, is described. This project is being partially funded by Illinois to demonstrate the feasibility of utilizing high-sulfur Illinois coal. Design production is 125,000 pounds per hour of 400 psig saturated steam. An Illinois EPA construction permit has been received, engineering design is under way, major equipment is on order, ground breaking occurred in January 1984 and planned commissioning date is late 1985. This paper describes the planned installation and the factors and analyses used to evaluate the technology and justify the project. Design of the project is summarized, including the boiler performance requirements, the PYROFLOW boiler, the coal, limestone and residue handling systems and the pollutant emission limitations.

Farbstein, S. B.; Moreland, T.

1984-01-01T23:59:59.000Z

449

Thermodynamics of atmospheric circulation on hot Jupiters  

E-Print Network (OSTI)

Atmospheric circulation on tidally-locked exoplanets is driven by the absorption and reradiation of heat from the host star. They are natural heat engines, converting heat into mechanical energy. A steady state is possible only if there is a mechanism to dissipate mechanical energy, or if the redistribution of heat is so effective that the Carnot efficiency is driven to zero. Simulations based on primitive, equivalent-barotropic, or shallow-water equations without explicit provision for dissipation of kinetic energy and for recovery of that energy as heat, violate energy conservation. More seriously perhaps, neglect of physical sources of drag may overestimate wind speeds and rates of advection of heat from the day to the night side.

J. Goodman

2008-10-07T23:59:59.000Z

450

Nucla circulating atmospheric fluidized bed demonstration project  

Science Conference Proceedings (OSTI)

Colorado-Ute Electric Association began a study to evaluate options for upgrading and extending the life of its Nucla power station in 1982. Located in southwestern Colorado near the town of Nucla, this station was commissioned in 1959 with a local bituminous coal as its design fuel for three identical stoker-fired units, each rated at 12.6 MW(e). Poor station efficiency, high fuel costs, and spiraling boiler maintenance costs forced the Nucla Station into low priority in the CUEA dispatch order as early as 1981. Among the options CUEA considered was to serve as a host utility to demonstrate Atmospheric Fluidized Bed Combustion (AFBC) technology. The anticipated environmental benefits and apparent attractive economics of a circulating AFBC led to Colorado-Ute's decision to proceed with the design and construction of a demonstration project in 1984 at the Nucla facility.

Not Available

1991-10-01T23:59:59.000Z

451

2007 Status Report: Savings Estimates for the ENERGY STAR(R) VoluntaryLabeling Program  

E-Print Network (OSTI)

Gas Price MBtu Oil Price MBtu Price Source c d e f g h i j jGas or Oil) - Central Air Conditioner - Air-Source HeatGas or Oil) - Central Air Conditioner - Air-Source Heat

Sanchez, Marla; Webber, Carrie A.; Brown, Richard E.; Homan, Gregory K.

2007-01-01T23:59:59.000Z

452

2005 Status Report Savings Estimates for the ENERGY STAR(R) Voluntary Labeling Program  

E-Print Network (OSTI)

Rate Electricit Carbon Oil Price Source b Source Rate SourceGas or Oil) - Central Air Conditioner - Air-Source HeatGas or Oil) - Central Air Conditioners - Air-Source Heat

Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla

2006-01-01T23:59:59.000Z

453

2003 status report savings estimates for the energy star(R) voluntary labeling program  

E-Print Network (OSTI)

for Carbon Heat Rate Oil Price Source b Electricity SourceGas or Oil) -Central Air Conditioner -Air-Source Heat Pump -Gas or Oil) - Central Air Conditioners - Air-Source Heat

Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla

2004-01-01T23:59:59.000Z

454

2006 Status Report Savings Estimates for the ENERGY STAR(R) Voluntary Labeling Program  

E-Print Network (OSTI)

Gas Price MBtu Oil Price MBtu Price Source Carbon EmissionsGas or Oil) - Central Air Conditioner - Air-Source HeatGas or Oil) - Central Air Conditioner - Air-Source Heat

Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla; Homan, Gregory K.

2006-01-01T23:59:59.000Z

455

2002 status report: Savings estimates for the ENERGY STAR(R) voluntary labeling program  

E-Print Network (OSTI)

for Carbon Source Rate Oil Price Source b Electricity SourceGas or Oil) -Central Air Conditioner -Air-Source Heat Pump -Gas or Oil) - Central Air Conditioners - Air-Source Heat

Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla; Koomey, Jonathan

2003-01-01T23:59:59.000Z

456

Calendar Year 2009 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network (OSTI)

Res. Gas Price Oil Price Price Sources Elec. Carbon EmissionGas or Oil) Central Air Conditioner Air-Source Heat PumpGas or Oil) Central Air Conditioner Air-Source Heat Pump

Homan, Gregory K

2011-01-01T23:59:59.000Z

457

Calendar Year 2008 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network (OSTI)

Res. Gas Price Oil Price Price Sources Elec. Carbon EmissionGas or Oil) Central Air Conditioner Air-Source Heat PumpGas or Oil) Central Air Conditioner Air-Source Heat Pump

Homan, GregoryK

2010-01-01T23:59:59.000Z

458

Calendar Year 2007 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network (OSTI)

Price MBtu Oil Price $/MBtu Price Sources, US DOE 3 CarbonGas or Oil) - Central Air Conditioner - Air-Source HeatGas or Oil) - Central Air Conditioner - Air-Source Heat

Sanchez, Marla Christine

2008-01-01T23:59:59.000Z

459

Savings estimates for the ENERGY STAR (registered trademark) voluntary labeling program: 2001 status report  

E-Print Network (OSTI)

Gas Price MBtu Oil Price MBtu Price Source The followingGas or Oil) -Central Air Conditioner -Air-Source Heat Pump -Gas or Oil) - Central Air Conditioners - Air-Source Heat

Webber, Carrie A.; Brown, Richard E.; Mahajan, Akshay; Koomey, Jonathan G.

2002-01-01T23:59:59.000Z

460

2004 status report: Savings estimates for the Energy Star(R) voluntarylabeling program  

E-Print Network (OSTI)

Rate Electricit Carbon Oil Price Source b Source Rate SourceGas or Oil) -Central Air Conditioner -Air-Source Heat Pump -Gas or Oil) - Central Air Conditioners - Air-Source Heat

Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Energy Basics: Solar Air Heating  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

EERE: Energy Basics Solar Air Heating Solar air heating systems use air as the working fluid for absorbing and transferring solar energy. Solar air collectors (devices to heat air...

462

Design and evaluation of lost circulation materials for severe environments  

DOE Green Energy (OSTI)

An independent analysis of lost circulation materials for geothermal applications has been completed using unique laboratory tools developed for the purpose. Test results of commercial materials as well as mathematical models for evaluating their performance are presented. Physical attributes that govern the performance of lost circulation materials are identified and correlated with test results. 9 refs., 27 figs., 4 tabs.

Loeppke, G.E.; Glowka, D.A.; Wright, E.K.

1988-01-01T23:59:59.000Z

463

Lost circulation technology workshop, October 9-10, 1984  

DOE Green Energy (OSTI)

This report summarizes the presentations and discussions of a workshop on lost circulation technology. The workshop identified and defined lost circulation problem areas in field operations, materials, mud effects, and standards. Problem solution needs were also categorized as requiring analytical evaluation and procedure, instrument, and material development.

Caskey, B.C. (ed.)

1985-03-01T23:59:59.000Z

464

Isokinetic air sampler  

DOE Patents (OSTI)

An isokinetic air sampler includes a filter, a holder for the filter, an air pump for drawing air through the filter at a fixed, predetermined rate, an inlet assembly for the sampler having an inlet opening therein of a size such that isokinetic air sampling is obtained at a particular wind speed, a closure for the inlet opening and means for simultaneously opening the closure and turning on the air pump when the wind speed is such that isokinetic air sampling is obtained. A system incorporating a plurality of such samplers provided with air pumps set to draw air through the filter at the same fixed, predetermined rate and having different inlet opening sizes for use at different wind speeds is included within the ambit of the present invention as is a method of sampling air to measure airborne concentrations of particulate pollutants as a function of wind speed.

Sehmel, George A. (Richland, WA)

1979-01-01T23:59:59.000Z

465

Defining the Effectiveness of UV Lamps Installed in Circulating Air Ductwork  

SciTech Connect

Ultraviolet; UV; UVC; UVGI; HVAC; ductwork; mold; fungus; effectiveness; microbial; dose; irradiance; reflectance; bacillis; aspergillis

Douglas VanOsdell; Karin Foarde

2002-11-30T23:59:59.000Z

466

The Adriatic Sea General Circulation. Part I: AirSea Interactions and Water Mass Structure  

Science Conference Proceedings (OSTI)

A comprehensive historical hydrographic dataset for the overall Adriatic Sea basin is analyzed in order to define the open ocean seasonal climatology of the basin. The authors also define the regional climatological seasons computing the average ...

A. Artegiani; E. Paschini; A. Russo; D. Bregant; F. Raicich; N. Pinardi

1997-08-01T23:59:59.000Z

467

Development of Refrigerant Change Indicator and Dirty Air Filter Sensor  

Science Conference Proceedings (OSTI)

The most common problems affecting residential and light commercial heating, ventilation, and air-conditioning (HVAC) systems are slow refrigerant leaks and dirty air filters. Equipment users are usually not aware of a problem until most of the refrigerant has escaped or the air filter is clogged with dirt. While a dirty air filter can be detected with a technology based on the air pressure differential across the filter, such as a ''whistling'' indicator, it is not easy to incorporate this technology into existing HVAC diagnostic equipment. Oak Ridge National Laboratory is developing a low-cost, nonintrusive refrigerant charge indicator and dirty air filter detection sensor. The sensors, based on temperature measurements, will be inexpensive and easy to incorporate into existing heat pumps and air conditioners. The refrigerant charge indicator is based on the fact that when refrigerant starts to leak, the evaporator coil temperature starts to drop and the level of liquid subcooling drops. When the coil temperature or liquid subcooling drops below a preset reading, a signal, such as a yellow warning light, can be activated to warn the equipment user that the system is undercharged. A further drop of coil temperature or liquid subcooling below another preset reading would trigger a second warning signal, such as a red warning light, to warn the equipment user that the unit now detects a leak and immediate action should be taken. The warning light cannot be turned off until it is re-set by a refrigeration repairman. To detect clogged air filters, two additional temperature sensors can be applied, one each across the evaporator. When the air filter is accumulating buildup, the temperature differential across the evaporator will increase because of the reduced airflow. When the temperature differential reaches a pre-set reading, a signal will be sent to the equipment user that the air filter needs to be changed. A traditional refrigerant charge indicator requires intrusion into the system to measure the refrigerant high-side and low-side pressures. Once the pressures are known, based on the equipment's refrigerant charging chart? or in most cases, based on the technician's experience? the refrigerant charging status is determined. However, there is a catch: by the time a refrigeration technician is called, most of the refrigerant has already escaped into the atmosphere. The new technology provides a real-time warning so that when, say, 20% of the refrigerant has leaked, the equipment users will be warned, even though the equipment is still functioning properly at rated capacity. Temperature sensors are becoming very accurate and very low in cost, compared with pressure sensors. Using temperature sensors to detect refrigerant charge status is inherently nonintrusive, inexpensive, and accurate. With the addition of two temperature sensors for detecting dirty air filters, the capability of the diagnostic equipment is further enhanced with very little added cost. This report provides laboratory test data on the change of indoor coil refrigerant temperature and subcooling as a function of refrigerant charge for a 2-ton split heat pump system. The data can be used in designing the indicators for refrigerant loss and dirty air filter sensors.

Mei, V.

2003-06-24T23:59:59.000Z

468

A Simplified General Circulation Model for a Baroclinic Ocean with Topography. Part I: Theory, Waves, and Wind-Driven Circulations  

Science Conference Proceedings (OSTI)

A new type of ocean general circulation model with simplified physics is described and tested for various simple wind-driven circulation problems. The model consists of the vorticity balance of the depth-averaged flow and a hierarchy of equations ...

Dirk Olbers; Carsten Eden

2003-12-01T23:59:59.000Z

469

Vermont Air Pollution Control Regulations, Ambient Air Quality...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ambient Air Quality Standards (Vermont) Vermont Air Pollution Control Regulations, Ambient Air Quality Standards (Vermont) Eligibility Utility Agricultural Investor-Owned Utility...

470

Vsd Oil Free Air Compressor, Vsd Oil Free Air Compressor ...  

U.S. Energy Information Administration (EIA)

Vsd Oil Free Air Compressor, You Can Buy Various High Quality Vsd Oil Free Air Compressor Products from Global Vsd Oil Free Air Compressor Suppliers ...

471

China Ga Air Compressor, China Ga Air Compressor Products ...  

U.S. Energy Information Administration (EIA)

China Ga Air Compressor, China Ga Air Compressor Suppliers and Manufacturers Directory - Source a Large Selection of Ga Air Compressor Products at ...

472

Oil Free Vsd Air Compressor, Oil Free Vsd Air Compressor ...  

U.S. Energy Information Administration (EIA)

Oil Free Vsd Air Compressor, You Can Buy Various High Quality Oil Free Vsd Air Compressor Products from Global Oil Free Vsd Air Compressor Suppliers ...

473

Screw Type Ac Air Compressor Manufacturers, Screw Type Ac Air ...  

U.S. Energy Information Administration (EIA)

Screw Type Ac Air Compressor, Screw Type Ac Air Compressor Manufacturers & Suppliers Directory - Find here Screw Type Ac Air Compressor Traders, ...

474

Air Conditioning and lungs  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Conditioning and lungs Name: freeman Status: NA Age: NA Location: NA Country: NA Date: Around 1993 Question: What affect does air conditioning have upon the lungs of the...

475

Design of Complex Systems to Achieve Passive Safety: Natural Circulation Cooling of Liquid Salt Pebble Bed Reactors  

E-Print Network (OSTI)

natural circulation solar water heater. Energy Conversionas water circulation in solar water heaters 60 , and passivewater circulation in solar water heaters 60 , and passive

Scarlat, Raluca Olga

2012-01-01T23:59:59.000Z

476

NUCLA Circulating Atmospheric Fluidized Bed Demonstration Project  

SciTech Connect

The report summarizes unit operating experience and test program progress for 1989 on Colorado-Ute Electric Association's Nucla CFB Demonstration Program. During this period, the objectives of the Nucla Station operating group were to correct problems with refractory durability, resolve primary air fan capacity limitations, complete the high ash and high sulfur coal tests, switch to Salt Creek coal as the operating fuel, and make the unit available for testing without capacity restrictions. Each of these objectives was addressed and accomplished, to varying degrees, except for the completion of the high sulfur coal acceptance tests. (VC)

Not Available

1992-02-01T23:59:59.000Z

477

Two-Way Feedback Interaction between the Thermohaline and Wind-Driven Circulations  

Science Conference Proceedings (OSTI)

The thermohaline circulation (THC) affects the meridional atmospheric temperature gradient and therefore the atmospheric wind and the wind-driven ocean circulation. The wind-driven circulation (WDC), in turn, affects the THC by the advection of ...

Douglas G. MacMynowski; Eli Tziperman

2006-05-01T23:59:59.000Z

478

The Arctic and Subarctic Ocean Flux of Potential Vorticity and the Arctic Ocean Circulation  

Science Conference Proceedings (OSTI)

According to observations, the Arctic Ocean circulation beneath a shallow thermocline can be schematized by cyclonic rim currents along shelves and over ridges. In each deep basin, the circulation is also believed to be cyclonic. This circulation ...

Jiayan Yang

2005-12-01T23:59:59.000Z

479

Examination of Isentropic Circulation Response to a Doubling of Carbon Dioxide Using Statistical Transformed Eulerian Mean  

Science Conference Proceedings (OSTI)

Responses of the atmospheric circulation to a doubling of CO2 are examined in a global climate model, focusing on the circulation on both dry and moist isentropes. The isentropic circulations are reconstructed using the statistical transformed ...

Yutian Wu; Olivier Pauluis

2013-06-01T23:59:59.000Z

480

Daytime Local Circulations and Their Interactions in the Seoul Metropolitan Area  

Science Conference Proceedings (OSTI)

Daytime local circulations and their interactions in the Seoul, South Korea, metropolitan area are investigated using a high-resolution mesoscale model. It is found that the urban-breeze circulation interacts strongly with other local circulations,...

Young-Hee Ryu; Jong-Jin Baik

2013-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioners circulate" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Mean Circulation of the Hamburg LSG OGCM and Its Sensitivity to the Thermohaline Surface Forcing  

Science Conference Proceedings (OSTI)

The sensitivity of the global ocean circulation to changes in surface heat flux forcing is studied using the Hamburg Large Scale Geostrophic (LSG) ocean circulation model. The simulated mean ocean circulation for appropriately chosen surface ...

Ernst Maier-Reimer; Uwe Mikolajewicz; Klaus Hasselmann

1993-04-01T23:59:59.000Z

482

Changes in Zonal Surface Temperature Gradients and Walker Circulations in a Wide Range of Climates  

Science Conference Proceedings (OSTI)

Variations in zonal surface temperature gradients and zonally asymmetric tropical overturning circulations (Walker circulations) are examined over a wide range of climates simulated with an idealized atmospheric general circulation model (GCM). ...

Timothy M. Merlis; Tapio Schneider

2011-09-01T23:59:59.000Z

483

Efficient Data Centers  

Science Conference Proceedings (OSTI)

Results and FindingsThis technical update provides an overview of airflow management using variable speed drives (VSDs) on direct expansion (DX) computer room air conditioners (CRACs), and particularly how reduced airflow can improve energy efficiency in data centers. VSDs on CRAC units coupled with good airflow management within a data center can have a dramatic impact on energy efficiency. Typically, a lot more cold air is circulated within conventional data centers ...

2012-12-20T23:59:59.000Z

484

Thermal Energy Storage  

Science Conference Proceedings (OSTI)

The Ice Bear30 Hybrid Air Conditionerthermal energy storage system150uses smart integrated controls, ice storage, and a dedicated compressor for cooling. The system is designed to provide cooling to interior spaces by circulating refrigerant within an additional evaporator coil added to a standard unitary air conditioner. The Ice Bear 30 is a relatively small size (5 ton), intended for use in residential and light commercial applications. This report describes EPRI tests of the Ice Bear 30, which is manu...

2009-12-14T23:59:59.000Z

485

The Role of Eddy-Tansport in the Thermohaline Circulation  

SciTech Connect

Several research themes were developed during the course of this project. (1) Low-frequency oceanic varibility; (2) The role of eddies in the Antarctic Circumpolar Current (ACC) region; (3) Deep stratification and the overturning circulation. The key findings were as follows: (1) The stratification below the main thermocline (at about 500m) is determined in the circumpolar region and then communicated to the enclosed portions of the oceans through the overturning circulation. (2) An Atlantic pole-to-pole overturning circulation can be maintained with very small interior mixing as long as surface buoyancy values are shared between the northern North Atlantic and the ACC region.

Dr. Paola Cessi

2011-11-17T23:59:59.000Z

486

Air Pollution- Local Air Quality (Ontario, Canada)  

Energy.gov (U.S. Department of Energy (DOE))

The Air Pollution regulation administered by the Ministry of the Environment enforces compliance to the standards set in the Ontario law. The law is phased in, with portions taking effect in 2010,...

487

On the World-wide Circulation of the Deeper Waters of the World Ocean  

E-Print Network (OSTI)

circulation of the Pacific Ocean: Flow patterns, tracers,circulation of the Indian Ocean: Flow patterns, tracers, andthe figures. Fig. 1 Pacific Ocean winds Fig. 2 Pacific Ocean

Reid, Joseph L

2009-01-01T23:59:59.000Z

488

Table Contents Page i 2013 Nonresidential Compliance Manual January 2014  

E-Print Network (OSTI)

Table B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods.....................................................3 Table C-1...........................................4 Table E-1 Gas and Oil Space Heater Test Methods

489

A P P L I A N C E EFFICIENCY REGULATIONS  

E-Print Network (OSTI)

Test Methods...........................40 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods ......................41 C.....................................................................................42 E-1 Gas and Oil Space Heater Test Methods

490

A P P L I A N C E August, 2003  

E-Print Network (OSTI)

Test Methods........................... 40 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods....................... 41 C ...................................................................................... 42 E-1 Gas and Oil Space Heater Test Methods

491

On the Determination of Age of Air Trends from Atmospheric Trace Species  

Science Conference Proceedings (OSTI)

Trace chemical species have been used in numerical models to calculate the age of air (AOA), which is a measure of the strength of the mean meridional circulation. The trend in the AOA has also been computed and found to be negative in ...

Rolando R. Garcia; William J. Randel; Douglas E. Kinnison

2011-01-01T23:59:59.000Z

492

Atmospheric Forcing of the Winter AirSea Heat Fluxes over the Northern Red Sea  

Science Conference Proceedings (OSTI)

The influence of the atmospheric circulation on the winter airsea heat fluxes over the northern Red Sea is investigated during the period 19852011. The analysis based on daily heat flux values reveals that most of the net surface heat exchange ...

Vassilis P. Papadopoulos; Yasser Abualnaja; Simon A. Josey; Amy Bower; Dionysios E. Raitsos; Harilaos Kontoyiannis; Ibrahim Hoteit

2013-03-01T23:59:59.000Z

493

Thin Air Breathing  

NLE Websites -- All DOE Office Websites (Extended Search)

Thin Air Breathing Thin Air Breathing Name: Amy Location: N/A Country: N/A Date: N/A Question: Why is it hard to breathe in thin air? What health dangers do mountain climbers face at high altitudes? Replies: Among the obvious dangers of losing ones footing, the oxygen available in the air is considerable less at higher altitudes. If I recall correctly, 21% of the atmosphere at standard temperature and pressure at sea level is composed of oxygen. This is less at higher altitudes. One can lose consciousness and even die in an oxygen deficient environment with changes from oxygen content to lower than 19.5%. This can unfortunate effect can occur within minutes. Dr. Myron The air is not really thin at high altitudes. The problem is that air pressure is lower. As altitude increases, air pressure decreases. In order for your lungs to fill with air, the air pressure in your lungs has to be less than the pressure of the air outside your lungs. Air moves from areas of higher pressure to lower pressure. As your diaphragm (the muscle that separates your chest cavity from your abdominal cavity) moves downward, the size of your chest cavity increases. This decreases the pressure in your chest and air flows in. When the diaphragm is up, it puts pressure on the chest cavity and the pressure in the lungs is greater than outside the lungs. Air flows out. This is an example of Boyle's Law. The movement of the diaphragm is controlled by the brainstem. Anyway-the reason that it is harder for some people to breathe at higher altitudes is that the air pressure differences aren't as great between the inside of the lungs and outside.

494

Property:Building/SPElectrtyUsePercCirculationFans | Open Energy  

Open Energy Info (EERE)

SPElectrtyUsePercCirculationFans SPElectrtyUsePercCirculationFans Jump to: navigation, search This is a property of type String. Circulation fans Pages using the property "Building/SPElectrtyUsePercCirculationFans" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 18.6715328229 + Sweden Building 05K0002 + 0.0 + Sweden Building 05K0003 + 3.84924044288 + Sweden Building 05K0004 + 13.5679722118 + Sweden Building 05K0005 + 10.115947775 + Sweden Building 05K0006 + 10.4348038368 + Sweden Building 05K0007 + 3.09034005771 + Sweden Building 05K0008 + 1.5024342653 + Sweden Building 05K0009 + 13.4365662073 + Sweden Building 05K0010 + 0.0 + Sweden Building 05K0011 + 2.75323793817 + Sweden Building 05K0012 + 15.8993705073 + Sweden Building 05K0013 + 1.11354848212 +

495