Sample records for air conditioner stac

  1. Covered Product Category: Residential Central Air Conditioners...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Central Air Conditioners Covered Product Category: Residential Central Air Conditioners The Federal Energy Management Program (FEMP) provides acquisition guidance for residential...

  2. Life-cycle cost and payback period analysis for commercial unitary air conditioners

    E-Print Network [OSTI]

    Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

    2004-01-01T23:59:59.000Z

    Baseline Efficient Air Conditioners . . . . . . 28 AverageEfficient Air Conditioners . . . . . . . . . . . . . . . . .Btu/h Commercial Air Conditioners . . . . . . . . . . . . .

  3. Determining benefits and costs of improved central air conditioner efficiencies

    E-Print Network [OSTI]

    Rosenquist, G.

    2010-01-01T23:59:59.000Z

    Products: Central Air Conditioners and Heat Pumps Energyof Improved Central Air Conditioner Efficiencies Authorsresidential-type central air conditioner energy-efficiency

  4. Dirty air conditioners: Energy implications of coil fouling

    E-Print Network [OSTI]

    Siegel, Jeffrey; Walker, Iain; Sherman, Max

    2002-01-01T23:59:59.000Z

    1473. Neal, L. 1992. Air Conditioner Efficiency in the Realof a Residential Air Conditioner. Proceedings of the 1992of new residential air conditioners in Phoenix, Arizona.

  5. DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS

    E-Print Network [OSTI]

    Dao, K.

    2013-01-01T23:59:59.000Z

    DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS K. Dao, M.ABSORPTION AIR CONDITIONERS AND HEAT PUMPS* K. DAO, M.

  6. AIR CONDITIONER REQUEST EXTREME MEDICAL CIRCUMSTANCES

    E-Print Network [OSTI]

    AIR CONDITIONER REQUEST DUE TO EXTREME MEDICAL CIRCUMSTANCES TO BE COMPLETED BY ATTENDING Moderate Significant Is the use of an air conditioner desirable Yes No OR essential Yes No to the management of allergy? Is the use of an air conditioner

  7. High-Efficiency Window Air Conditioners - Building America Top...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    High-Efficiency Window Air Conditioners - Building America Top Innovation High-Efficiency Window Air Conditioners - Building America Top Innovation This photo shows a window air...

  8. Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners

    E-Print Network [OSTI]

    Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners John Shugars, Consultant ofcommercialpackaged air conditioners, explore the reasons behindthis efficiency gap, and assess opportunities). Although sales of rooftop air conditioners have steadily increased over the past decade, the efficiency

  9. DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS

    E-Print Network [OSTI]

    Dao, K.

    2013-01-01T23:59:59.000Z

    SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS K.Driven Absorption Air-Conditioner", K. Dao, M. Simmons, R.SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS* K.

  10. Four Central Air Conditioners Determined Noncompliant With Energy...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard October...

  11. Electrolux Gibson Air Conditioner and Equator Clothes Washer...

    Broader source: Energy.gov (indexed) [DOE]

    Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing...

  12. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    Blast-Type Air Conditioners and Heat Pump. The correspondingair/air air conditioners and heat pumps. Some improvementsconnected air- conditioner (heat pump) units, household

  13. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    Results for Room Air Conditioners Nan Zhou David FridleyTable of Contents I. Air Conditioner Round Robin TestingAir Conditioners..

  14. Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement

    E-Print Network [OSTI]

    Bode, Josh

    2013-01-01T23:59:59.000Z

    Measuring Short-term Air Conditioner Demand Reductions forMeasuring Short-term Air Conditioner Demand Reductions forpilots have shown that air conditioner (AC) electric loads

  15. Technical and economic analysis of energy efficiency of Chinese room air conditioners

    E-Print Network [OSTI]

    Fridley, David G.; Rosenquist, Gregory; Jiang, Lin; Li, Aixian; Xin, Dingguo; Cheng, Jianhong

    2001-01-01T23:59:59.000Z

    Sector Study of Room Air Conditioners in China) , ChinaQi Shichang ( China’s Air Conditioner Market ), China Lightand Constant-Speed Air Conditioners." ASHRAE Transactions.

  16. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01T23:59:59.000Z

    Final Summary Report by Air Conditioner Evaluation Standardreversible residential air conditioners and heat pumps usingJFS, 2007: “New Air Conditioners with Infrared Sensors

  17. Rating of Mixed Split Residential Air Conditioners

    E-Print Network [OSTI]

    Domanski, P. A.

    1988-01-01T23:59:59.000Z

    A methodology is presented for rating the performance of mixed, split residential air conditioners. The method accounts for the impact on system performance of the indoor evaporator, expansion device and fan; three major components that are likely...

  18. Stirling Air Conditioner for Compact Cooling

    SciTech Connect (OSTI)

    None

    2010-09-01T23:59:59.000Z

    BEETIT Project: Infinia is developing a compact air conditioner that uses an unconventional high efficient Stirling cycle system (vs. conventional vapor compression systems) to produce cool air that is energy efficient and does not rely on polluting refrigerants. The Stirling cycle system is a type of air conditioning system that uses a motor with a piston to remove heat to the outside atmosphere using a gas refrigerant. To date, Stirling systems have been expensive and have not had the right kind of heat exchanger to help cool air efficiently. Infinia is using chip cooling technology from the computer industry to make improvements to the heat exchanger and improve system performance. Infinia’s air conditioner uses helium gas as refrigerant, an environmentally benign gas that does not react with other chemicals and does not burn. Infinia’s improvements to the Stirling cycle system will enable the cost-effective mass production of high-efficiency air conditioners that use no polluting refrigerants.

  19. The effects of galvanic corrosion on air conditioner performance

    E-Print Network [OSTI]

    Grisham, Phillip Ryan

    2001-01-01T23:59:59.000Z

    Corrosion of air conditioner outdoor heat exchangers (condensers) poses a significant problem for consumers living in coastal regions. This research sought to experimentally determine effects of galvanic corrosion on air conditioner condenser coils...

  20. ROOM AIR CONDITIONER WALL MOUNTED type

    E-Print Network [OSTI]

    Kleinfeld, David

    SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Reciprocating Compressor Models Indoor unit.6 - 11.4 ----- MOISTURE REMOVAL ( / hr) 2.0 1.8 2.7 2.7 4.3 3 AIR CIRCULATION - Hi (m / hr) 800 800 1

  1. Energy conservation standards for room air conditioners

    SciTech Connect (OSTI)

    Rosenquist, G.J. [Lawrence Berkeley National Lab., CA (United States)

    1998-12-31T23:59:59.000Z

    The National Appliance Energy Conservation Act (NAECA) of 1987 established minimum energy-efficiency standards for room air conditioners, which became effective on January 1, 1990. The 1990 minimum energy-efficiency ratios (EER) range from 8.0 to 9.0 (Btu/h)/W (2.34 to 2.64 W/W). As required by NAECA, the Department of Energy (DOE) must also consider amending the room air conditioner standards that went into effect in 1990. As a result, the DOE issued a Notice of Proposed Rulemaking (NOPR) in March 1994 proposing new energy-efficiency standards for several products including room air conditioners. DOE received an extensive number of comments in response to the updated standards that were proposed. A reanalysis was conducted incorporating these comments, resulting in revised estimates of the cost and efficiency increases for more efficient room air conditioner designs. This paper describes the cost-efficiency analysis of design options carried out in support of DOE`s effort to revise the energy-efficiency standards that were proposed for room air conditioners in March 1994. The analysis shows that for the most popular classes of room air conditioners (classes without reverse cycle, with louvered sides, and with capacities ranging from less than 5000 to 20,000 Btu/h [1758 to 5860 W]) EERs of approximately 10.0 (Btu/h)/W (2.93 W/W) can be achieved by incorporating commonly used technologies, such as high-efficiency rotary compressors, grooved refrigerant tubing, slit-type fins, subcoolers, and permanent split capacitor fan motors. Even greater increases in efficiency can be realized with brushless permanent magnet fan motors, enlarged heat exchanger coils, and variable-speed compressors.

  2. Assessing the Impact of Measurement Policy on the Accuracy of Certified Energy Efficiency Ratio for Split-System Air Conditioners

    E-Print Network [OSTI]

    Yu, Bingyi

    2013-01-01T23:59:59.000Z

    Efficiency of Unitary Air Conditioners and Heat Pumps,and Validation of Unitary Air Conditioner and Heat PumpC.W. (1994). Room Air Conditioner System Modeling, Air

  3. Covered Product Category: Residential Central Air Conditioners

    Broader source: Energy.gov [DOE]

    FEMP provides acquisition guidance across a variety of product categories, including residential central air conditioners (CACs), which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  4. Covered Product Category: Room Air Conditioners

    Broader source: Energy.gov [DOE]

    FEMP provides acquisition guidance across a variety of product categories, including room air conditioners, which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  5. EECBG Direct Equipment Purchase Air Conditioner Guide Equipment Type

    E-Print Network [OSTI]

    EECBG Direct Equipment Purchase Air Conditioner Guide Equipment Type Size Category (Btu/h) Size.ahridirectory.org/ceedirectory/pages/ac/cee/defaultSearch.aspx 12,000 Btu/h = 1 ton Less than 65,000 Btu/h Air Conditioners, Air Cooled Air Conditioners, Water completed by the California Energy Commission at a rate of 12,000 Btu/h per ton of air conditioning Source

  6. Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India

    E-Print Network [OSTI]

    McNeil, Michael A.

    2010-01-01T23:59:59.000Z

    for Refrigerators and Air Conditioners in India. Michael A.followed by room air conditioners. Both of these appliancesfrost-free units. Room air conditioners in India have

  7. Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges

    E-Print Network [OSTI]

    Phadke, Amol

    2014-01-01T23:59:59.000Z

    Efficiency of Room Air Conditioners in India: OpportunitiesStar Labeled room Air Conditioners. ” Ministry of Power (of Superefficient Room Air Conditioners,” Lawrence Berkeley

  8. APPROVED ICE STORAGE AIR CONDITIONERS Revised as of 06-18-2008

    E-Print Network [OSTI]

    APPROVED ICE STORAGE AIR CONDITIONERS Revised as of 06-18-2008 The following vendors and their ice storage air conditioners models can be used in the ice storage air conditioner compliance option. Input

  9. Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners

    E-Print Network [OSTI]

    McNeil, Michael A.; Iyer, Maithili

    2008-01-01T23:59:59.000Z

    Standard Levels for Room Air Conditioners Michael A. McNeilFigure 1 – MEPS for 1.5 ton Window Air Conditioners – 1994-4 Figure 2 – Air Conditioner Test Data and Rating Plan -

  10. DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner...

    Energy Savers [EERE]

    Action Against AeroSys, Inc. for Failure to Certify Air Conditioners and Heat Pumps Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard...

  11. Air Conditioner Compressor Performance Model

    SciTech Connect (OSTI)

    Lu, Ning; Xie, YuLong; Huang, Zhenyu

    2008-09-05T23:59:59.000Z

    During the past three years, the Western Electricity Coordinating Council (WECC) Load Modeling Task Force (LMTF) has led the effort to develop the new modeling approach. As part of this effort, the Bonneville Power Administration (BPA), Southern California Edison (SCE), and Electric Power Research Institute (EPRI) Solutions tested 27 residential air-conditioning units to assess their response to delayed voltage recovery transients. After completing these tests, different modeling approaches were proposed, among them a performance modeling approach that proved to be one of the three favored for its simplicity and ability to recreate different SVR events satisfactorily. Funded by the California Energy Commission (CEC) under its load modeling project, researchers at Pacific Northwest National Laboratory (PNNL) led the follow-on task to analyze the motor testing data to derive the parameters needed to develop a performance models for the single-phase air-conditioning (SPAC) unit. To derive the performance model, PNNL researchers first used the motor voltage and frequency ramping test data to obtain the real (P) and reactive (Q) power versus voltage (V) and frequency (f) curves. Then, curve fitting was used to develop the P-V, Q-V, P-f, and Q-f relationships for motor running and stalling states. The resulting performance model ignores the dynamic response of the air-conditioning motor. Because the inertia of the air-conditioning motor is very small (H<0.05), the motor reaches from one steady state to another in a few cycles. So, the performance model is a fair representation of the motor behaviors in both running and stalling states.

  12. absorption air conditioner: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    absorption air conditioner First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 AIR CONDITIONER REQUEST...

  13. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01T23:59:59.000Z

    replacement options have and are being developed. Choice of Refrigerant: The most efficient air conditioners

  14. Commercial Central Air Conditioners, Purchasing Specifications for Energy-Efficient Products (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2011-02-01T23:59:59.000Z

    Energy efficiency purchasing specifications for federal procurements of commercial central air conditioners.

  15. Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates 

    E-Print Network [OSTI]

    O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

    1996-01-01T23:59:59.000Z

    provided rebates to residential customers for purchasing high efficiency air conditioners and heat pumps. The rebates have helped increase the demand for higher efficiency air conditioning units. However, even the most efficient system will not perform... quanm the effect of air leakage in the return air duct from a hot attic space on the high-temperature performance of air conditioners and heat pump systems. Air conditioner performance is quantified in terms of capacity, Energy Efficiency Ratio (EER...

  16. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    E-Print Network [OSTI]

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-01-01T23:59:59.000Z

    Central Air Conditioners and Heat Pumps Energy ConservationCentral Air Conditioners and Heat Pumps. Washington DC:Central Air Conditioners and Heat Pumps Energy Conservation

  17. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    E-Print Network [OSTI]

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-01-01T23:59:59.000Z

    Products: Central Air Conditioners and Heat Pumps EnergyResidential Central Air Conditioners and Heat Pumps.Products: Central Air Conditioners and Heat Pumps Energy

  18. YMGI Through-the-Wall Air Conditioner Determined Noncompliant...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    on October 11, 2012, to YMGI Group, LLC (YMGI) regarding through-the-wall split system central air conditioner basic model TTWC-18K-31B. DOE enforcement testing revealed that...

  19. DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS

    E-Print Network [OSTI]

    Dao, K.

    2013-01-01T23:59:59.000Z

    AIR CONDITIONERS AND HEAT PUMPS K. Dao, M. Wahlig, E. Wali,are liquid paths. DM: multistage pump driver, driven by highvapor. DW: main circulation pump driven by strong absorbent.

  20. adsorption air conditioner: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    establishment of a network of solarair conditioner is an Arkla gas-fired ammonia-water chiller, modified for operation using solar- Dols, C. 2010-01-01 177 Air Pollution Spring...

  1. automobile air conditioners: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    (1) and the establishment of a network of solarair conditioner is an Arkla gas-fired ammonia-water chiller, modified for operation using solar- Dols, C. 2010-01-01 263 Air...

  2. Improving Air-Conditioner and Heat Pump Modeling (Presentation)

    SciTech Connect (OSTI)

    Winkler, J.

    2012-03-01T23:59:59.000Z

    A new approach to modeling residential air conditioners and heat pumps allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted 'behind-the-scenes' without negatively impacting the reliability of energy simulations.

  3. Residential Air Conditioner Direct Load Control "Energy Partners Program"

    E-Print Network [OSTI]

    Cook, J. D.

    1994-01-01T23:59:59.000Z

    RESIDENTIAL AIR CONDITIONER DIRECT LOAD CONTROL "ENERGY PARTNERS PROGRAMn John D. Cook Supervisor Houston ABSTRACT Demand side management programs like Energy Partners can provide an effective peak reducing capability which within a.... In this partnership the customer allows HLfP to install a I switch on his/her air conditioner or heat pump and i periodically cycle the unit off during the hottest summer 1 days. In return the customer benefits by receiving an incentive payment, as well...

  4. Assessing the Impact of Measurement Policy on the Accuracy of Certified Energy Efficiency Ratio for Split-System Air Conditioners

    E-Print Network [OSTI]

    Yu, Bingyi

    2013-01-01T23:59:59.000Z

    of Unitary Air Conditioners and Heat Pumps, ASHRAE, 1791of Unitary Air Conditioner and Heat Pump Simulation Modelsfor Rating Unitary Air-Conditioning and Heat Pump Equipment,

  5. STRATEGIC PLAN TO REDUCE THE ENERGY IMPACT OF AIR CONDITIONERS

    E-Print Network [OSTI]

    CALIFORNIA ENERGY COMMISSION STRATEGIC PLAN TO REDUCE THE ENERGY IMPACT OF AIR CONDITIONERS Acknowledgements This report represents the efforts of many experts from the air conditioning industry who Manufacturer Freus Air Conditioning Jim Bazemore Consultant Energy Market Innovations, Inc. Doug Beaman

  6. Installation of Window Air Conditioners Page 1 of 2 Virginia Polytechnic Institute and State University No. 5705 Rev.: 3

    E-Print Network [OSTI]

    Buehrer, R. Michael

    Installation of Window Air Conditioners Page 1 of 2 Virginia Polytechnic Institute and State __________________________________________________________________________________ Subject: Installation of Window Air Conditioners........................................................................................................................................1 1. Purpose To define a policy for installation of window air conditioners that avoids exterior

  7. Truman STaTe univerSiTyWELCOME HOME! Air Conditioner

    E-Print Network [OSTI]

    Gering, Jon C.

    Truman STaTe univerSiTyWELCOME HOME! Air Conditioner Welcome toTruman State University air conditioner requests.If you need air conditioning and are assigned to Centennial,Grim,or Fair conditioning, you will need to bring your own air conditioner unit that is 6000 BTUs or less.A non

  8. Air Conditioner User Behavior in a Master-Metered Apartment Building

    E-Print Network [OSTI]

    Kempton, W.; Feuermann, D.; McGarity, A. E.

    1987-01-01T23:59:59.000Z

    Air conditioner operation was studied in order to understand how energy consumption and peak power are determined by user behavior, equipment operation and building characteristics. In a multi-family building, thirteen room air conditioners were...

  9. Influence of Air Conditioner Operation on Electricity Use and Peak Demand

    E-Print Network [OSTI]

    McGarity, A. E.; Feuermann, D.; Kempton, W.; Norford, L. K.

    1987-01-01T23:59:59.000Z

    Electricity demand due to occupant controlled room air conditioners in a large mater-metered apartment building is analyzed. Hourly data on the electric demand of the building and of individual air conditioners are used in analyses of annual...

  10. STATE OF CALIFORNIA CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS

    E-Print Network [OSTI]

    STATE OF CALIFORNIA CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS CEC Volume Single Zone Unitary Air Conditioner and Heat Pump Systems (Page 1 of 4) Project Name CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS CEC-MECH-3A (Revised 08

  11. Laboratory Performance Testing of Residential Window Air Conditioners

    SciTech Connect (OSTI)

    Winkler, J.; Booten, C.; Christensen, D.; Tomerlin, J.

    2013-03-01T23:59:59.000Z

    Window air conditioners are the dominant cooling product for residences, in terms of annual unit sales. They are inexpensive, portable and can be installed by the owner. For this reason, they are an attractive solution for supplemental cooling, for retrofitting air conditioning into a home which lacks ductwork, and for renters. Window air conditioners for sale in the United States are required to meet very modest minimum efficiency standards. Four window air conditioners' performance were tested in the Advanced HVAC Systems Laboratory on NREL's campus in Golden, CO. In order to separate and study the refrigerant system's performance, the unit's internal leakage pathways, the unit's fanforced ventilation, and the leakage around the unit resulting from installation in a window, a series of tests were devised that focused on each aspect of the unit's performance. These tests were designed to develop a detailed performance map to determine whole-house performance in different climates. Even though the test regimen deviated thoroughly from the industry-standard ratings test, the results permit simple calculation of an estimated rating for both capacity and efficiency that would result from a standard ratings test. Using this calculation method, it was found that the three new air conditioners' measured performance was consistent with their ratings. This method also permits calculation of equivalent SEER for the test articles. Performance datasets were developed across a broad range of indoor and outdoor operating conditions, and used them to generate performance maps.

  12. Monitoring and evaluation of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached houses in Austin, Texas

    SciTech Connect (OSTI)

    Burns, R.; Hough, R.E. (Fleming (W.S.) and Associates, Inc., Syracuse, NY (United States))

    1991-10-01T23:59:59.000Z

    The US DOE initiated this project to evaluate the performance of an air conditioner retrofit program in Austin, Texas. The City's Austin's Resource Management Department pursued this project to quantify the retrofit effect of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached homes. If successfully implemented, this retrofit program could help defer construction of a new power plant which is a major goal of this department. The project compares data collected from 12 houses during two cooling seasons under pre-retrofit and then post-retrofit air conditioner units. The existing low-efficiency air conditioners were monitored during the 1987 cooling season, replaced during the 1987--88 heating season with new, smaller sized, high-efficiency units, and then monitored again during the 1988 cooling season. Results indicated that the air conditioner retrofits reduce the annual air conditioner electric consumption and peak electric demand by an average of 38%. When normalized to the nominal capacity of the air conditioner, average demand savings were 1.12 W/ft{sup 2} and estimated annual energy savings were 1.419 kWh/ft{sup 2}. Individual air conditioner power requirements were found to be a well defined function of outdoor temperature as expected. In the absence of detailed data, estimates of the peak demand reductions of new air conditioners can be made from the manufacturer's specifications. Air conditioner energy consumption proved to be strongly linear as a function of the outdoor temperature as expected when taken as an aggregate. No noticeable differences in the diversity factor of the air conditioner usage were found. Analysis of the retrofit effect using PRISM yields estimates of the reduction in normalized annual consumption (NAC) and annual cooling consumption of 12% and 30%. 2 refs., 11 figs., 17 tabs.

  13. Development of vehicle magnetic air conditioner (VMAC) technology. Final report

    SciTech Connect (OSTI)

    Gschneidner, Karl A., Jr.; Pecharsky, V.K.; Jiles, David; Zimm, Carl B.

    2001-08-28T23:59:59.000Z

    The objective of Phase I was to explore the feasibility of the development of a new solid state refrigeration technology - magnetic refrigeration - in order to reduce power consumption of a vehicle air conditioner by 30%. The feasibility study was performed at Iowa State University (ISU) together with Astronautics Corporation of America Technology Center (ACATC), Madison, WI, through a subcontract with ISU.

  14. ISSUANCE 2015-06-09: Energy Conservation Program: Energy Conservation Standards for Room Air Conditioners; Request for Information

    Broader source: Energy.gov [DOE]

    Energy Conservation Program: Energy Conservation Standards for Room Air Conditioners; Request for Information

  15. Assessing the Impact of Measurement Policy on the Accuracy of Certified Energy Efficiency Ratio for Split-System Air Conditioners

    E-Print Network [OSTI]

    Yu, Bingyi

    2013-01-01T23:59:59.000Z

    cooling energy efficiency ratio for split-system air conditioners is not well characterized. This research

  16. Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates

    E-Print Network [OSTI]

    O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

    1996-01-01T23:59:59.000Z

    were designed for testing systems with cooling capacities of up to 10 tons. The unit used for return air leakage tests was a 3.5 ton (12.3 kW) split system air conditioner with TXV expansion and a scroll compressor. It had a seasonal energy... leakage on capacity, power, and energy efficiency ratio (EER) of an air conditioner were quantified. The air conditioner was subjected to an outdoor temperature of 100°F (37.g°C). The indoor conditions for the no leakage test were set at 75OF (23.g...

  17. Assessment of Environmentally Friendly Refrigerants for Window Air Conditioners

    SciTech Connect (OSTI)

    Bansal, Pradeep [ORNL] [ORNL; Shen, Bo [ORNL] [ORNL

    2014-01-01T23:59:59.000Z

    This paper presents technical assessment of environmentally friendly refrigerants for window air conditioners that currently use refrigerant R410A for residential and commercial applications. The alternative refrigerants that are studied for its replacement include R32, R600a, R290, R1234yf, R1234ze and a mixture of R32 (90% molar concentration) and R125 (10% molar concentration). Baseline experiments were performed on a window unit charged with R410A. The ORNL Heat Pump Design Model was calibrated with the baseline data and was used to assess the comparative performance of the WAC with alternative refrigerants. The paper discusses the advantages and disadvantages of each refrigerants and their suitability for window air conditioners.

  18. Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype

    SciTech Connect (OSTI)

    Kozubal, E.; Woods, J.; Judkoff, R.

    2012-04-01T23:59:59.000Z

    This report documents the design of a desiccant enhanced evaporative air conditioner (DEVAP AC) prototype and the testing to prove its performance. Previous numerical modeling and building energy simulations indicate a DEVAP AC can save significant energy compared to a conventional vapor compression AC (Kozubal et al. 2011). The purposes of this research were to build DEVAP prototypes, test them to validate the numerical model, and identify potential commercialization barriers.

  19. The Impact of Energy Recovery on Window Air-conditioner Efficiency

    E-Print Network [OSTI]

    Luo, Q.; Tang, C.; Liao, K.

    2006-01-01T23:59:59.000Z

    An experimental energy recovering air-conditioner can produce fresh air exchange heat with exhaust air in the heat exchanger, which has no additional moving parts. The EER of the experimental air-conditioner (EAC) is increased by 17.4~37.3 percent...

  20. Determining benefits and costs of improved central air conditioner efficiencies

    SciTech Connect (OSTI)

    Rosenquist, G.; Levok, A.; Chan, P.; McMahon, J.

    2001-01-12T23:59:59.000Z

    Economic impacts on individual consumers from possible revisions to U.S. residential-type central air conditioner energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a central air conditioner and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers due to modest increases in efficiency are significant. For an efficiency increase of 20percent over the existing minimum standard (i.e., 12 SEER), 35percent of households with central air conditioners experience significant LCC savings, with an average savings of $453, while 25percent show significant LCC losses, with an average loss of $158 compared to apre-standard LCC average of $5,170. The remainder of the population (40percent) are largely unaffected.

  1. Advanced Thin Film Thermoelectric Systems forEfficient Air-Conditioner...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    device fabrication and the design of novel coolingheating engines exploiting thermal storage for efficient air-conditioners in automobiles ghoshal.pdf More Documents &...

  2. 2015-02-12 Issuance: Test Procedures for Portable Air Conditioners...

    Broader source: Energy.gov (indexed) [DOE]

    to this document. PAC TP NOPR.pdf More Documents & Publications 2014-05-05 Issuance: Test Procedure for Portable Air Conditioners; Notice of Data Availability ISSUANCE...

  3. Measured Impacts of Air Conditioner Condenser Shading

    E-Print Network [OSTI]

    Parker, D. S.; Barkaszi, S. F.; Sonne, J. K.

    1996-01-01T23:59:59.000Z

    A study has been conducted by the Florida Solar Energy Center (FSEC) to examine if space cooling energy savings can be achieved from shading of residential air conditioning (AC) condenser units. The investigation consisted of before...

  4. Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications: Preprint

    SciTech Connect (OSTI)

    Lowenstein, A.; Slayzak, S.; Kozubal, E.

    2006-07-01T23:59:59.000Z

    A novel liquid-desiccant air conditioner that dries and cools building supply air will transform the use of direct-contact liquid-desiccant systems in HVAC applications, improving comfort, air quality, and providing energy-efficient humidity control.

  5. Development of a room air conditioner design model

    E-Print Network [OSTI]

    Penson, Steven Brad

    1988-01-01T23:59:59.000Z

    model was developed for this thesis by making major modifications to a heat pump model previously developed by Oak Ridge National Laboratory: (1) Addition of a subcooler, (2) Revision of the capillary tube model, (3) Addition of multi-grooved tubes... circuiting . 11 3. 1 Ideal refrigeration cycle on a pressure-enthalpy diagram 3. 2 3. 3 Tube-in-condensate subcooler. Tube-in-tubs subcooler, . 15 . 17 3. 4 Simplified diagram of a room air conditioner . 19 3. 5 Capillary flow factors. . 30 3. 6...

  6. An Analysis of Efficiency Improvements in Room Air Conditioner 

    E-Print Network [OSTI]

    O'Neal, D. L.; Penson, S. B.

    1988-01-01T23:59:59.000Z

    . There are two public domain models that we have considered using for this analysis: the Oak Ridge National Laboratory (ORNL) heat pump model [1] and the Arthur D. Little (ADL) room air conditioner model [2]. The ORNL model was completed in 1981. Although... regions. 3.2 The Oak Ridge model allows construction of various types of coils using different tube diameters, wall thicknesses, tube spacing, and fin thicknesses. The ORNL model allows use of wavy, louvered, or other fins if data are available...

  7. Problem Type Problem Type Description Air Conditioning Air conditioner not working, leaking, etc

    E-Print Network [OSTI]

    Tennessee, University of

    Problem Type Problem Type Description Air Conditioning Air conditioner not working, leaking, etc, Microfridges Doors and Hardware Door repair/replace Lock, latch or hinge repair, key stuck; Lost or stolen key, repair or replace Shades/Blinds Window treatment - repair or replace Washer/Dryer Washer/Dryer repair

  8. An Evaluation of Steady-State Dehumidification Characteristics of Residential Central Air Conditioners, Final Report

    E-Print Network [OSTI]

    O'Neal, D. L.; Chan, N.; Somasundaram, S.; Katipamula, S.

    1987-01-01T23:59:59.000Z

    Conditioners, Air Source HeatPumps, and Sound-Rated Outdoor Unitary Equipment that ARI publishes twice a yearCl], In addition to the ARI certification, many manufacturerspublish detailed performance (capacity, efficiency, and dehumidification) data....2 - Performance and hardware data collectedfor this survey. 3.2 References 1. "Directory of Certified Unitary Air Conditioners, Air Source HeatPumps, and Sound-Rated Outdoor Unitary Equipment", Semi-Annual Issues, Air Conditioning and Refrigeration Institute...

  9. An Analysis of Efficiency Improvements in Residential Sized Heat Pumps and Central Air Conditioners 

    E-Print Network [OSTI]

    O'Neal, D. L.; Boecker, C. L.; Penson, S. B.

    1986-01-01T23:59:59.000Z

    This report summarizes: (1) the performance improvements possible for central air conditioners and heat pumps using conventional design improvements, (2) the development of a methodology for estimating the seasonal performance of variable speed heat...

  10. Determination of the Transient Dehumidification Characteristics of High Efficiency Central Air Conditioners 

    E-Print Network [OSTI]

    Katipamula, S.; O'Neal, D. L.; Somasundaram, S.

    1987-01-01T23:59:59.000Z

    A series of tests were performed to assesses the dehumidifying performance of residential central air conditioners (CACs). The performance studies were based on factors such as: (i) dynamic performance (ii) the ASHRAE ...

  11. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    Australia The energy efficiency labeling in Australia adoptson the energy efficiency control list in Australia areenergy efficiency standards and labeling programs for room air conditioners in the United States, European Union, Japan, Australia

  12. Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations

    SciTech Connect (OSTI)

    Cutler, D.; Winkler, J.; Kruis, N.; Christensen, C.; Brendemuehl, M.

    2013-01-01T23:59:59.000Z

    This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost effective equipment upgrade opportunities and efficiency improvements in residential buildings.

  13. Modeling the effects of Refrigerant Charging on Air Conditioner Performance Characteristics For Three Expansion Devices

    E-Print Network [OSTI]

    Farzad, Mohsen

    An experimental and analytical study concerned with the off-design refrigerant charging of air conditioners is presented. A series of experiments were conducted to characterize the effects of refrigerant charge and type of expansion device...

  14. A Preliminary Evaluation of Alternative Liquid Desiccants for a Hybrid Desiccant Air Conditioner

    E-Print Network [OSTI]

    Studak, J. W.; Peterson, J. L.

    1988-01-01T23:59:59.000Z

    and the condenser of a vapor-compression air conditioner. The liquid desiccants studied were lithium chloride, lithium bromide, calcium chloride, and triethylene glycol. Each candidate desiccant was subjected to a screening process which weighed the merits...

  15. The Impact of Residential Air Conditioner Charging and Sizing on Peak Electrical Demand 

    E-Print Network [OSTI]

    Neal, L.; O'Neal, D. L.

    1992-01-01T23:59:59.000Z

    . Dennis L. O'Neal Department of Mechanical Engineering Texas A & M University College Station, TX Federal and state governments can also impact the choice of central air conditioners/heat pumps through requirements mandated by legislation.... The National Energy Efficient Appliances Act requires an SEER of JO for all split-system central air conditioners or heat pumps manufactured after January 1, 1992, and an SEER of 9.7 for all package systems manufactured after January 1, 1993 [I]. Electric...

  16. Applying a Domestic Water-cooled Air-conditioner in Subtropical Cities

    E-Print Network [OSTI]

    Lee, W.; Chen, H.

    2006-01-01T23:59:59.000Z

    the energy and environmental benefits of WACS over AACS applying to commercial buildings with central air-conditioning. This paper presents an experimental study on the performance of a 3.36 kW prototype water-cooled air conditioner. The prototype is a self...

  17. ISSUANCE 2015-07-17: Energy Conservation Program: Energy Conservation Standards for Room Air Conditioners; Request for Information, Extension of the Public Comment Period

    Broader source: Energy.gov [DOE]

    Energy Conservation Program: Energy Conservation Standards for Room Air Conditioners; Request for Information, Extension of the Public Comment Period

  18. ISSUANCE 2015-06-08: Energy Conservation Program: Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps, Final Rule

    Broader source: Energy.gov [DOE]

    Energy Conservation Program: Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps, Final Rule

  19. Swozzle based burner tube premixer including inlet air conditioner for low emissions combustion

    DOE Patents [OSTI]

    Tuthill, Richard Sterling (Bolton, CT); Bechtel, II, William Theodore (Scotia, NY); Benoit, Jeffrey Arthur (Scotia, NY); Black, Stephen Hugh (Duanesburg, NY); Bland, Robert James (Clifton Park, NY); DeLeonardo, Guy Wayne (Scotia, NY); Meyer, Stefan Martin (Troy, NY); Taura, Joseph Charles (Clifton Park, NY); Battaglioli, John Luigi (Glenville, NY)

    2002-01-01T23:59:59.000Z

    A burner for use in a combustion system of a heavy-duty industrial gas turbine includes a fuel/air premixer having an air inlet, a fuel inlet, and an annular mixing passage. The fuel/air premixer mixes fuel and air into a uniform mixture for injection into a combustor reaction zone. The burner also includes an inlet flow conditioner disposed at the air inlet of the fuel/air premixer for controlling a radial and circumferential distribution of incoming air. The pattern of perforations in the inlet flow conditioner is designed such that a uniform air flow distribution is produced at the swirler inlet annulus in both the radial and circumference directions. The premixer includes a swozzle assembly having a series of preferably air foil shaped turning vanes that impart swirl to the airflow entering via the inlet flow conditioner. Each air foil contains internal fuel flow passages that introduce natural gas fuel into the air stream via fuel metering holes that pass through the walls of the air foil shaped turning vanes. By injecting fuel in this manner, an aerodynamically clean flow field is maintained throughout the premixer. By injecting fuel via two separate passages, the fuel/air mixture strength distribution can be controlled in the radial direction to obtain optimum radial concentration profiles for control of emissions, lean blow outs, and combustion driven dynamic pressure activity as machine and combustor load are varied.

  20. An Evaluation of Steady-State Dehumidification Characteristics of Residential Central Air Conditioners, Final Report 

    E-Print Network [OSTI]

    O'Neal, D. L.; Chan, N.; Somasundaram, S.; Katipamula, S.

    1987-01-01T23:59:59.000Z

    Conditioners, Air Source HeatPumps, and Sound-Rated Outdoor Unitary Equipment that ARI publishes twice a yearCl], In addition to the ARI certification, many manufacturerspublish detailed performance (capacity, efficiency, and dehumidification) data... due to on-off cycling is estimated and used with data fromTest B to calculate the Seasonal Energy Efficiency Ratio (SEER). *The test procedure used to rate air conditioners and heat pumps isreproduced in the appendix. 2.1 (2.1) where, While the amount...

  1. Are You Planning to Bring an Air Conditioner? Welcome to Truman State University and the services available through the Disability Services Office. Part of

    E-Print Network [OSTI]

    Gering, Jon C.

    Are You Planning to Bring an Air Conditioner? Welcome to Truman State University and the services conditioner requests. If you need air conditioning and are assigned to Centennial, Grim, or Fair Apartments conditioning, you will need to bring your own air conditioner unit that is 6000 BTUs or less. A non

  2. Air Conditioner Efficiency Under Hot Dry and Hot Humid Conditions - The Utility Perspective

    E-Print Network [OSTI]

    Amarnath, A.

    94304 E-mail: aamarnath@epri.com Phone: (650) 855-1007 Energy efficient residential air conditioning is important to utilities and their customers. In almost all parts of the U.S., an air conditioner for a dwelling has a high peak demand... energy efficiency programs; ? Actively engage in the USDOE standards proceedings through technical input from collaborative organizations like EPRI and EEI; ? Support emerging technology procurement of air conditioning equipment that is super...

  3. Technical and economic analysis of energy efficiency of Chinese room air conditioners

    SciTech Connect (OSTI)

    Fridley, David G.; Rosenquist, Gregory; Jiang, Lin; Li, Aixian; Xin, Dingguo; Cheng, Jianhong

    2001-02-01T23:59:59.000Z

    China has experienced tremendous growth in the production and sales of room air conditioners over the last decade. Although minimum room air conditioner energy efficiency standards have been in effect since 1989, no efforts were made during most of the 1990's to update the standard to be more reflective of current market conditions. In 1999, China's State Bureau of Technical Supervision (SBTS) included in their annual plan the development and revision of the 1989 room air conditioner standard, and experts from SBTS worked together with LBNL to analyze the new standards. Based on the engineering and life cycle-cost analyses performed, the most predominant type of room air conditioner in the Chinese market (split-type with a cooling capacity between 2500 and 4500 W (8500 Btu/h and 15,300Btu/h)) can have its efficiency increased cost-effectively to an energy efficiency ratio (EER) of 2.92 W/W (9.9 Btu/hr/W). If an EER standard of 2.92 W/W became effective in 2001, Chinese consumers would be estimated to save over 3.5 billion Yuan (420 million U.S. dollars) over the period of 2001-2020. Carbon emissions over the same period would be reduced by approximately 12 million metric tonnes.

  4. 7-55E An office that is being cooled adequately by a 12,000 Btu/h window air-conditioner is converted to a computer room. The number of additional air-conditioners that need to be installed is to be determined.

    E-Print Network [OSTI]

    Bahrami, Majid

    7-20 7-55E An office that is being cooled adequately by a 12,000 Btu/h window air-conditioner is converted to a computer room. The number of additional air-conditioners that need to be installed/h. Then noting that each available air conditioner provides 4,000 Btu/h cooling, the number of air- conditioners

  5. Energy Consumption Estimation for Room Air-conditioners Using Room Temperature Simulation with One-Minute Intervals

    E-Print Network [OSTI]

    Wang, F.; Yoshida, H.; Matsumoto, K.

    2006-01-01T23:59:59.000Z

    For the purpose of developing optimized control algorithm for room air-conditioners to ensure their energy efficiency, a short time interval (i.e., one minute) simulation of building thermal performance is necessary because the sampling time...

  6. The Influence of Operating Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner

    E-Print Network [OSTI]

    Yu, J.; Yang, C.; Guo, R.; Wu, D.; Chen, H.

    2006-01-01T23:59:59.000Z

    A field investigation was carried out in an office building of Changsha city in winter and summer, the influence of different running modes, curtain styles and room temperature set point on energy consumption of room air conditioner (RAC...

  7. An Evaluation of the Effects of Refrigerant Charge on a Residential Central Air Conditioner with Orifice Expansion 

    E-Print Network [OSTI]

    O'Neal, D. L.; Ramsey, C. J.; Farzad, M.

    1989-01-01T23:59:59.000Z

    conditioning and heat pump performance testing. Dew point and room temperatures can be maintained within +/-0.2 F of the set point. The room temperature was controlled by a Texas Instruments TI-550 controller which was integrated into the control system... Air Conditioner with Capillary Tube Expansion", ESL/CON/88-1, Energy Systems Laboratory, Texas A&M University, July 1988. 2. Department of Energy, "Test Procedures for Central Air- Conditioners, Including Heat Pumps", Federal Register, pp. 76700...

  8. Techno-Economic Analysis of Indian Draft Standard Levels for RoomAir Conditioners

    SciTech Connect (OSTI)

    McNeil, Michael A.; Iyer, Maithili

    2007-03-01T23:59:59.000Z

    The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency. In support of BEE's refrigerator program, Lawrence Berkeley National Laboratory (LBNL) produced an analysis of national impacts of standards in collaboration with the Collaborative Labeling and Standards Program (CLASP). That analysis drew on LBNL's experience with standards programs in the United States, as well as many other countries. Subsequently, as part of the process for setting optimal levels for air conditioner regulations, CLASP commissioned LBNL to provide support to BEE in the form of a techno-economic evaluation of air conditioner efficiency technologies. This report describes the methodology and results of this techno-economic evaluation. The analysis consists of three components: (1) Cost effectiveness to consumers of efficiency technologies relative to current baseline. (2) Impacts on the current market from efficiency regulations. (3) National energy and financial impacts. The analysis relied on detailed and up-to-date technical data made available by BEE and industry representatives. Technical parameters were used in conjunction with knowledge about air conditioner use patterns in the residential and commercial sectors, and prevailing marginal electricity prices, in order to give an estimate of per-unit financial impacts. In addition, the overall impact of the program was evaluated by combining unit savings with market forecasts in order to yield national impacts. LBNL presented preliminary results of these analyses in May 2006, at a meeting of BEEs Technical Committee for Air Conditioners. This meeting was attended by a wide array of stakeholder, including industry representatives, engineers and consumer advocates. Comments made by stakeholders at this meeting are incorporated into the final analysis presented in this report. The current analysis begins with the Rating Plan drafted by BEE in 2006, along with an evaluation of the market baseline according to test data submitted by manufacturers. MEPS, label rating levels, and baseline efficiencies are presented in Section 2. First, we compare Indian MEPS with current standards in other countries, and assess their relative stringency. Baseline efficiencies are then used to estimate the fraction of models likely to remain on the market at each phase of the program, and the impact on market-weighted efficiency levels. Section 3 deals with cost-effectiveness of higher efficiency design options. The cost-benefit analysis is grounded in technical parameters provided by industry representatives in India. This data allows for an assessment of financial costs and benefits to consumers as a result of the standards and labeling program. A Life-Cycle Cost (LCC) calculation is used to evaluate the impacts of the program at the unit level, thus providing some insight into the appropriateness of the levels chosen, and additional opportunities for further ratcheting. In addition to LCC, we also calculate payback periods, cost of conserved energy (CCE), and return on investment (ROI). Finally, Section 4 covers national impacts. This is an extension of unit level estimates in the two previous sections. Extrapolation to the national level depends on a forecast of air conditioner purchases (shipments), which we describe here. Following the cost-benefit analysis, we construct several efficiency scenarios including the BEE plan, but also considering further potential for efficiency improvement. These are combined with shipments through a stock accounting model in order to forecast air conditioner energy consumption in each sc

  9. 13 SEER Standard for Central Air Conditioners and Heat Pumps (released in AEO2005)

    Reports and Publications (EIA)

    2005-01-01T23:59:59.000Z

    In January 2004, after years of litigation in a case that pitted environmental groups and Attorneys General from 10 states against the U.S. Secretary of Energy, the U.S. Court of Appeals for the Second Circuit reestablished the central air conditioner and heat pump standard originally set in January 200. The Courts ruling, which struck down a May 2002 rollback of the 2001 standard to a 12 Seasonal Energy Efficiency Ratio (SEER) mandates that all new central air conditioners and heat pumps meet a 13 SEER standard by January 2006, requiring a 30% increase in efficiency relative to current law. The Annual Energy Outlook 2005 reference case incorporates the 13 SEER standard as mandated by the Courts ruling.

  10. air conditioner units: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Air Service White Paper series. The ... Wittman, Michael D. 2013-05-07 65 Proposal for an Adsorption Solar-Driven Air-Conditioning Unit for Public Offices Texas A&M University -...

  11. air conditioners electronic: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    the issue of path planning is addressed for unmanned air vehicles (UAVs) cooperative joint-forces electronic attack operating in a hostile environment. Specifically, the...

  12. air conditioners: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of California eScholarship Repository Summary: chamber, passive sampling, passive solar house, measurementhouse, we planed the distribution of fresh air, passivepassive...

  13. Model-Based Commissioning for Filters in Room Air Conditioners 

    E-Print Network [OSTI]

    Wang, F.; Yoshida, H.; Kitagawa, H.; Matsumoto, K.; Goto, K.

    2004-01-01T23:59:59.000Z

    This paper proposes a model that can estimate filter resistance. Two sorts of value are used as inputs to estimate filter resistance. One is the power consumed by the fan in the indoor unit and the other is the thermal performance. For the room air...

  14. Model-Based Commissioning for Filters in Room Air Conditioners

    E-Print Network [OSTI]

    Wang, F.; Yoshida, H.; Kitagawa, H.; Matsumoto, K.; Goto, K.

    2004-01-01T23:59:59.000Z

    This paper proposes a model that can estimate filter resistance. Two sorts of value are used as inputs to estimate filter resistance. One is the power consumed by the fan in the indoor unit and the other is the thermal performance. For the room air...

  15. Measure Guideline: Air Conditioner Diagnostics, Maintenance, and Replacement

    SciTech Connect (OSTI)

    Springer, D.; Dakin, B.

    2013-03-01T23:59:59.000Z

    This guideline responds to the need for an efficient means of identifying, diagnosing, and repairing faults in air conditioning systems in existing homes that are undergoing energy upgrades. Inadequate airflow due to constricted ducts or undersized filters, improper refrigerant charge, and other system defects can be corrected at a fraction of the cost of equipment replacement and can yield significant savings. The guideline presents a two-step approach to diagnostics and repair.

  16. Product Standards for Air Conditioners (Japan) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation,Pillar Group BV Jump to: navigation,Power RentalAreas-|LogPrincipleProblemsAir

  17. Covered Product Category: Room Air Conditioners | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"Wave theJuly 30, 2013DepartmentEnterpriseDepartmentofRoom Air

  18. List of Central Air conditioners Incentives | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, searchOf Kilauea Volcano,LakefrontLighthouse SolarI JumpListBoilersListCeilingAir

  19. Energy Consumption Estimation for Room Air-conditioners Using Room Temperature Simulation with One-Minute Intervals 

    E-Print Network [OSTI]

    Wang, F.; Yoshida, H.; Matsumoto, K.

    2006-01-01T23:59:59.000Z

    of simulated energy consumption can match the measured data. The simulation accuracy of room air temperature and energy consumption during the air-conditioner start-up period is not good and needs to be improved in future research. But in general...

  20. Monitoring the Performance of a Residential Central Air Conditioner under Degraded Conditions on a Test Bench 

    E-Print Network [OSTI]

    Palani, M.; O'Neal, D. L.; Haberl, J. S.

    1992-01-01T23:59:59.000Z

    constituted 17.2% of the total failure. The failure rates of compressors was 13.5% and outdoor fans was about 11.5%. Lewis surveyed 492 large HVAC dealers to compile information on heat pump service life [5]. He discovered that refrigerant leaks were the major... valve increases. PREDICTION OF DEGRADED CONDITIONS There are several steady state simulation programs which are available to predict the design conditions of air conditioners and heat pumps [20, 21]. The ORNL and NIST models are popular and extensively...

  1. 2014-05-05 Issuance: Test Procedure for Portable Air Conditioners; Notice of Data Availability

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register notice of data availabilty regarding test procedures for portable air conditioners, as issued by the Deputy Assistant Secretary for Energy Efficiency on May 5, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

  2. Energy Impacts of Oversized Residential Air Conditioners -- Simulation Study of Retrofit Sequence Impacts

    SciTech Connect (OSTI)

    Booten, C.; Christensen, C.; Winkler, J.

    2014-11-01T23:59:59.000Z

    This research addresses the question of what are the energy consequences for oversizing of an air conditioner in a home. Conventional wisdom holds that oversizing the AC results in significant energy penalties. However, the reason for this was shown to be due to crankcase heaters and not due to cycling performance of the AC, and is only valid for a particular set of assumptions. Adding or removing individual characteristics, such as ducts or crankcase heaters, can have measurable impacts on energy use. However, with all other home characteristics held constant, oversizing the AC generally has a small effect on cooling energy use, even if the cycling performance of the unit is poor. The relevant aspects of air conditioner modeling are discussed to illustrate the effects of the cycling loss coefficient, Cd, capacity, climate, ducts and parasitic losses such as crankcase heaters. A case study of a typical 1960's vintage home demonstrates results in the context of whole building simulations using EnergyPlus.

  3. Effects of Air Conditioner Use on Real-World Fuel Economy

    SciTech Connect (OSTI)

    Huff, Shean P [ORNL; West, Brian H [ORNL; Thomas, John F [ORNL

    2013-01-01T23:59:59.000Z

    Vehicle data were acquired on-road and on a chassis dynamometer to assess fuel consumption under several steady cruise conditions and at idle. Data were gathered for various air conditioner (A/C) settings and with the A/C off and the windows open. Two vehicles were used in the comparisonstudy: a 2009 Ford Explorer and a 2009 Toyota Corolla. At steady speeds between 64.4 and 112.7 kph (40 and 70 mph), both vehicles consumed more fuel with the A/C on at maximum cooling load (compressor at 100% duty cycle) than when driving with the windows down. The Explorer maintained this trend beyond 112.7 kph (70 mph), while the Corolla fuel consumption with the windows down matched that of running the A/C at 120.7 kph (75 mph), and exceeded it at 128.7 kph (80 mph). The largest incremental fuel consumption rate penalty due to air conditioner use occurred was nearly constant with a weakslight trend of increasing consumption with increasing compressor (and vehicle) speed. Lower consumption is seenobserved at idle for both vehicles, likely due to the low compressor speed at this operating point

  4. Energy savings and economics of advanced control strategies for packaged air conditioners with gas heat

    SciTech Connect (OSTI)

    Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

    2013-10-01T23:59:59.000Z

    This paper presents an evaluation of the potential energy savings from adding advanced control to existing packaged air conditioners. Advanced control options include air-side economizer, multi-speed fan control, demand control ventilation and staged cooling. The energy and cost savings from the different control strategies individually and in combination are estimated using the EnergyPlus detailed energy simulation program for four building types, namely, a small office building, a stand-alone retail building, a strip mall building and a supermarket building. For each of the four building types, the simulation was run for 16 locations covering all 15 climate zones in the U.S. The maximum installed cost of a replacement controller that provides acceptable payback periods to owners is estimated.

  5. EA-1892: Direct Final Rule Energy Conservation Standards for Residential Furnaces and Residential Central Air Conditioners & Heat Pumps

    Broader source: Energy.gov [DOE]

    This EA evaluates the environmental impacts of a proposal to adopt energy conservation standards for various consumer products and certain commercial and industrial equipment, including residential furnaces and residential air conditioners and heat pumps, as required by the Energy Policy and Conservation Act, as amended (42 U.S.C. 6291 et seq.)

  6. Modeling of a second-generation solar-driven Rankine air conditioner. Final report

    SciTech Connect (OSTI)

    Denius, M.W.; Batton, W.D.

    1984-07-01T23:59:59.000Z

    Ten configurations of a second-generation (2G), solar-powered, Rankine-driven air conditioner were simulated and the data presented for use in companion studies. The results of the analysis show that the boiling-in-collector (BIC) configuration generates more power per collector area than the other configurations. The models used to simulate the configuration are presented in this report. The generated data are also presented. Experimental work was done under this study to both improve a novel refrigerant and oil lubrication system for the centrifugal compressor and investigate the aerodynamic unloading characteristics of the centrifugal compressor. The information generated was used to define possible turbo-gearbox configurations for use in the second generation computer simulation.

  7. Life-cycle cost and payback period analysis for commercial unitary air conditioners

    SciTech Connect (OSTI)

    Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

    2004-03-31T23:59:59.000Z

    This report describes an analysis of the economic impacts of possible energy efficiency standards for commercial unitary air conditioners and heat pumps on individual customers in terms of two metrics: life-cycle cost (LCC) and payback period (PBP). For each of the two equipment classes considered, the 11.5 EER provides the largest mean LCC savings. The results show how the savings vary among customers facing different electricity prices and other conditions. At 11.5 EER, at least 80% of the users achieve a positive LCC savings. At 12.0 EER, the maximum efficiency analyzed, mean LCC savings are lower but still positive. For the {ge} $65,000 Btu/h to <135,000 Btu/h equipment class, 59% of users achieve a positive LCC savings. For the $135,000 Btu/h to <240,000 Btu/h equipment class, 91% of users achieve a positive LCC savings.

  8. 2014-03-06 Issuance: Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps; Notice of Proposed Rulemaking

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register notice of proposed rulemaking regarding test procedures for packaged terminal air conditioners and packaged terminal heat pumps, as issued by the Deputy Assistant Secretary on March 6, 2014.

  9. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    E-Print Network [OSTI]

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-01-01T23:59:59.000Z

    Central Air Conditioners and Heat Pumps Energy ConservationW.R. Coleman. 1990. “Heat Pump Life and Compressor LongevityC.C.. 1990. “Predicting Future Heat Pump Production Volume

  10. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    SciTech Connect (OSTI)

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-10-10T23:59:59.000Z

    In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER.

  11. Modeled and measured effects of compressor downsizing in an existing air conditioner/heat pump in the cooling mode

    SciTech Connect (OSTI)

    Levins, W.P.; Rice, C.K.; Baxter, V.D.

    1996-05-01T23:59:59.000Z

    It is not uncommon to find oversized central air conditioners in residences. HVAC contractors sometimes oversize central air conditioners for one reason or another--some to the point that they may be 100% larger than needed to meet the load. Retrofit measures done to improve house envelope and distribution system efficiency also contribute to HVAC oversizing, as they reduce house heating and cooling loads. Proper sizing of an air conditioner or heat pump allows more efficient operation and provides a more comfortable environment than a highly oversized unit. Another factor that lowers operating efficiency is an improper refrigerant charge. Field inspections have revealed that about half of the units checked were not properly charged. An option available to homeowners with oversized air conditioners is to replace the existing compressor with a smaller, more efficient compressor, rather than purchasing a new, smaller unit. Such a retrofit may be economically justified, especially during a compressor failure, provided the oversizing of the existing unit is not too great. A used, 15-year old, single-package heat pump with a capillary tube expansion device on the indoor coil was purchased and tested in a set of environmental chambers to determine its cooling performance at various conditions. The system was also modeled to estimate its existing performance, and that with two different types of retrofitted state-of-the-art (SOA) efficient compressors with about 30% less capacity than the original compressor. This reduced the overall system cooling capacity by about 25%. Modeling estimated that the retrofit would increase system EER at 95 F by 30%, SEER by 34%, and reduce power demand by 39% compared to the existing unit. Reduced cycling losses account for the higher increase in SEER.

  12. Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India

    SciTech Connect (OSTI)

    McNeil, Michael A.; Iyer, Maithili

    2009-05-30T23:59:59.000Z

    The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptive frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.

  13. An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with a Thermal Expansion Valve

    E-Print Network [OSTI]

    Farzad, M.; O'Neal, D. L.

    1989-01-01T23:59:59.000Z

    by the manufacturer for a specific indoor and outdoor temperatures. Once the full charge was determined, the unit was subjected to 40%, 30%, 20%, 15%, 10%, and 5% undercharging and 5%, 10%, 15%, and 20% overcharging of refrigerant by mass. The fully charged tests were... CONDITION All tests were performed on a split system central air conditioner provided by the Trane company. To determine the proper amount of refrigerant charge needed in the system and the unit's corresponding performance, charging specifications...

  14. Performance characteristics of a turbo expander substituted for expansion valve on air-conditioner

    SciTech Connect (OSTI)

    Cho, Soo-Yong [Department of Mechanical and Aerospace Engineering (ReCAPT), Gyeongsang National University, 900 Gajoa-dong, Jinju 660-701 (Korea); Cho, Chong-Hyun [School of Mechanical and Aerospace Engineering, Gyeongsang National University, 900 Gajoa-dong, Jinju 660-701 (Korea); Kim, Chaesil [Department of Mechanical Engineering, Changwon National University, 9 Sarim-dong, Changwon 641-773 (Korea)

    2008-09-15T23:59:59.000Z

    An experimental study is conducted on a small turbo expander which could be applied to the expansion process in place of expansion valves in refrigerator or air-conditioner to improve the cycle efficiency by recovering energy from the throttling process. The operating gas is HFC134a and the maximum cooling capacity of experiment apparatus is 32.7 kW. Four different turbo expanders are tested to find the performance characteristics of the turbo expander when they operate at a low partial admission rate. The partial admission rate is 1.70% or 2.37, and expanders are operated in the supersonic flow. In the experiment, pressure and temperature are measured at 10 different locations in the experimental apparatus. In addition to these measurements, output power at the turbo expander is measured through a generator installed on a rotor shaft with the rotational speed. Performance data of the turbo expander are obtained at many part load operations by adjusting the output power of the generator. A maximum of 15.8% total-to-static efficiency is obtained when the pressure ratio and the partial admission ratio are 2.37 and 1.70%, respectively. Experimental results show that the optimal velocity ratio decreases when the pressure ratio is decreased, and peak efficiencies, which are obtained at locally maximized efficiency depending on the operating condition, vary linearly against the subcooling temperature or the pressure ratio. (author)

  15. air-conditioners furnaces air: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of California eScholarship Repository Summary: chamber, passive sampling, passive solar house, measurementhouse, we planed the distribution of fresh air, passivepassive...

  16. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    SciTech Connect (OSTI)

    Zhou, Nan; Fridley, David; Zheng, Nina; Pierrot, Andre

    2010-06-07T23:59:59.000Z

    In recent years China's energy consumption has increased rapidly. The problem of high energy consumption intensity and low energy utilization efficiency is serious, and the contradiction between economic development and energy and environmental resources has become increasingly acute, making energy conservation and consumption reduction an important society-wide concern. At the same time, global climate change has and will continue to have profound impacts on human survival and development, and is another major challenge to all countries. In order to accelerate China's energy conservation and emission reduction work, the National Leading Group to Address Climate Change, Energy Conservation and Emission Reduction was founded with Premier Wen Jiabao as the head, and the 'Comprehensive Work Program of Energy Conservation and Emission Reduction' and 'China's National Program of Addressing Climate Change' were issued, under which China's energy conservation and emission reduction work has been fully deployed. Efforts to promote energy efficiency have been further strengthened in all levels of government, and various policies and measures have progressively been issued and implemented. In addition, based on China's experience with implementing energy-saving priority strategies over the past 20+ years, our government established a goal of a 20% decrease in energy consumption per unit GDP in the 'Eleventh Five-year Development Plan'. Furthermore, in November 2009, in order to support global greenhouse gas emission reduction activities and promote China's low carbon economic development, the government established a further 40-50% reduction in energy consumption per unit GDP by 2020 compared to the year 2005. Improving energy utilization efficiency by scientific and technological progress will undoubtedly play an important role in achieving the above stated objectives. The improvement of energy efficiency of energy consuming products has always been an important component of all countries energy strategies. As we all know, a very large amount of total energy consumption is due to energy consuming products and equipment, which account for about 50% of China's total energy consumption. However, the current average energy utilization efficiency of this sector is only about 60%, 10 percent lower than the international advanced level. Therefore, China's energy consuming products and equipment sector holds great energy-saving potential. On the other hand, the energy supplied to these products is mainly from fossil fuel combustion, a major source of greenhouse gas (GHG) emissions. Therefore, improving the energy efficiency and augmenting the market share of market-dominant energy consuming products is of significant importance to achieving China's energy saving and emission reduction target and is an effective means to deal with energy and environmental constraints and climate change issues. Main energy consuming products generally include widely-used home appliances, industrial equipment, office equipment, transportation vehicles, etc. China is one of the major manufacturers and exporters of energy end-using products such as air-conditioners, refrigerators, televisions, etc. Their overall energy efficiency is comparatively low and the products are poorly designed, leading to great energy-saving potential. For example, electricity consumption of air conditioners accounts for about 20% of China's total electricity consumption and 40% of the summer electricity peak load in large and medium cities. However, less than 5% of units sold in the domestic market in 2009 reached the standard's highly efficient level of grade 2 above. The electricity consumption of electric motors and their related drive systems accounts for about 60% of China's total electricity consumption; however, less than 2% of the domestic market share consists of energy-efficient electric motor products. Promoting the energy efficiency and market shares of main energy-consuming products has become an important determinant of achieving energy conservation and emission reduc

  17. The Effect of Reduced Evaporator Air Flow on the Performance of a Residential Central Air Conditioner 

    E-Print Network [OSTI]

    Palani, M.; O'Neal, D.; Haberl, J.

    1992-01-01T23:59:59.000Z

    surveyed 492 large HVAC dealers to compile information on heat pump service life [5]. He discovered that refrigerant leaks were the major cause for failure, totaling 19% of failed units. Compressor motor circuits and mechanical part failures were 16... Lewis, J. E.; 1987. "Survey of residential air-to-air heat pump service life and maintenance issues", ASHRAE Transactions, Vol. 93, Part 2, p. p. I II I - 1127. [6J Silver, T.; 1989. "Training for the Future", Contracting Business, December 1989, p...

  18. Development of Temperature and Humidity-Based Indicators for Diagnosing Problems in Low Tonnage, Split System Air Conditioners

    E-Print Network [OSTI]

    Watt, J. B.; O'Neal, D. L.; Haberl, J. S.

    1998-01-01T23:59:59.000Z

    of meeting a given cooling load; and equipment safety, or the ability to maintain equipment longevity by avoiding equipment-life-reducing conditions such as compressor slugging (no superheat) or lack of compressor cooling (high superheat) or seal...DEVELOPMENT OF TEMPERATURE AND HUMIDITY-BASED INDICATORS FOR DIAGNOSING PROBLEMS IN LOW TONNAGE, SPLIT SYSTEM AIR CONDITIONERS Jim Watt Jeff Haberl, P.E., PhD. Dennis O'Neai, P.E., PhD. CES/Way International, Inc. Energy Systems Laboratory Energy...

  19. An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with Capillary Tube Expansion

    E-Print Network [OSTI]

    Farzad, M.; O'Neal, D. L.

    1988-01-01T23:59:59.000Z

    of the coil was 20.94 ft2 with refrigerant tube sizes of 3/8". The outdoor fan was located on the top of the outdoor coil. The fan specifications are given in Table 3.1. Figure 3.3 - Detail of Outdoor Test Section 25 Table 3.1 - Fan Specification...ESL-TR-88/07-01 AN EVALUATION OF IMPROPER REFRIGERANT CHARGE ON THE PERFORMANCE OF A SPLIT SYSTEM AIR CONDITIONER WITH CAPILLARY TUBE EXPANSION FINAL REPORT Submitted by Mohsen Farzad Dennis L. O'Neal Prepared For ENERGY SYSTEMS LABORATORY RESEARCH...

  20. Experimental analysis of a window air conditioner with a R-22 and R32/R125/R134a mixture

    SciTech Connect (OSTI)

    Mei, V.C.; Chen, F.C.; Chen, D.T. [Oak Ridge National Lab., TN (United States); HuangFu, E.P. [USDOE, Washington, DC (United States)

    1995-07-01T23:59:59.000Z

    Much experimental and theoretical analysis of potential R-22 replacements has been accomplished. However, published information about the experimental analysis of any off-the-shelf air conditioner with a potential R-22 replacement at realistic, operating conditions is still rare. This type of work could be useful because it provides baseline data for comparing the performance of R-22 and its potential replacement at drop-in conditions. In this study, an off-the-shelf window air conditioner was tested at Air Conditioning and Refrigeration Institute (ARI)-rated indoor conditions and at different ambient temperatures, including the ARI-rated outdoor condition, with R-22 and with its potential replacement, a ternary mixture of R-32(30%)/R-125(10%)/R-134a(60%) (the ternary mixture). A test rig was built that provided for baseline operation and for the option of operating the system with a flooded evaporator by means of liquid over-feeding (LOF). The test results indicated the cooling capacity of the ternary mixture was 7.7% less than that of R-22 at 95{degrees}F ambient for baseline operation. The cooling capacity for both refrigerants improved when a flooded evaporator, or LOF, was used. For LOF operation, the cooling capacity of the ternary mixture was only 1.1% less than that of R-22. The ternary mixture had slightly higher compressor discharge pressure, a lower compressor discharge temperature, slightly lower compressor power consumption, and a higher compressor high/low pressure ratio.

  1. The Explorationon the Energy Saving Potential of an Innovative Dual-temperature Air Conditioner and the Mechanism of the Theoretical Mixed Refrigeration Cycl

    E-Print Network [OSTI]

    Zhao,L.; Zhao,X.; Hu,A.

    2014-01-01T23:59:59.000Z

    The Exploration on the Energy Saving Potential of an Innovative Dual-temperature Air Conditioner and the Mechanism of the Theoretical Mixed Refrigeration Cycle Zhao Lei, Zhao Xijin, Hu Andu Professor, graduate student, graduate student...-temperature air conditioning system and its corresponding theoretical mixed refrigeration cycle are proposed. This consists of a separate air handling unit and a metal radiation panel as the dual-temperature evaporators, a compressor, a condenser, two thermal...

  2. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01T23:59:59.000Z

    HETAC, “High Efficiency Thermal Air Conditioning”, http://Refrigeration and Air Conditioning Industry Association,variable air volume air conditioning system for buildings”,

  3. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    C Dry bulb. air inlet. indoor side ºC Wet bulb. air inlet.indoor side ºC Dry bulb. air outlet.indoor side ºC Wet bulb. air outlet. indoor side ºC

  4. Improving Best Air Conditioner Efficiency by 20-30% through a High Efficiency Fan and Diffuser Stage Coupled with an Evaporative Condenser Pre-Cooler

    SciTech Connect (OSTI)

    Parker, Danny S; Sherwin, John R; Raustad, Richard

    2014-04-10T23:59:59.000Z

    The Florida Solar Energy Center (FSEC) conducted a research project to improve the best residential air conditioner condenser technology currently available on the market by retrofitting a commercially-available unit with both a high efficiency fan system and an evaporative pre-cooler. The objective was to integrate these two concepts to achieve an ultra-efficient residential air conditioner design. The project produced a working prototype that was 30% more efficient compared to the best currently-available technologies; the peak the energy efficiency ratio (EER) was improved by 41%. Efficiency at the Air-Conditioning and Refrigeration Institute (ARI) standard B-condition which is used to estimate seasonal energy efficiency ratio (SEER), was raised from a nominal 21 Btu/Wh to 32 Btu/Wh.

  5. Cornell's (LSC) project began providing 16,000 tons of cooling (1 ton of cooling = 12,000 Btu/hr, or approximately one large residential window air conditioner) to Cornell University's Ithaca

    E-Print Network [OSTI]

    Keinan, Alon

    window air conditioner) to Cornell University's Ithaca campus in July of 2000. This project has almost completely replaced mechanical refrigeration for the Cornell district cooling system with the following benefits: · Greater LSC has replaced

  6. Modeling the effects of Refrigerant Charging on Air Conditioner Performance Characteristics For Three Expansion Devices 

    E-Print Network [OSTI]

    Farzad, Mohsen

    1990-01-01T23:59:59.000Z

    a small refrigerant charge. A new heat exchanger model based on tube-by-tube simulation was developed and integrated into the ORNL heat pump model. The model was capable of simulating the steady state response of a vapor compression air-to-air heat...

  7. Investigations on Vapour Compression Air Conditioner with Direct Contact Desiccant Loop over Condenser and Evaporator

    E-Print Network [OSTI]

    Maiya, M. P.; Ravi, J.; Tiwari, S.

    2010-01-01T23:59:59.000Z

    Perceived air quality increases when relative humidity is decreased till about 30% in the range of comfort temperature. In the present scenario, humidity is considered as a pollutant. Hence, a controlled environment not only at low temperature...

  8. Testing and Economic Evaluation of a High Efficiency 10-ton Rooftop Air Conditioner

    E-Print Network [OSTI]

    O'Neal, D. L.; Davis, M. A.

    2006-11-09T23:59:59.000Z

    In 1993, the U.S. Environmental Protection Agency initiated a project to design, build and demonstrate a high efficiency commercial rooftop air conditioning unit. The unit was designed by Hibberd Consulting of Westminster, Colorado, and was built...

  9. Fault detection methods for vapor-compression air conditioners using electrical measurements

    E-Print Network [OSTI]

    Laughman, Christopher Reed.

    2008-01-01T23:59:59.000Z

    (cont.) This method was experimentally tested and validated on a commercially available air handler and duct system. In the second class of faults studied, liquid refrigerant, rather than vapor, enters the cylinder of a ...

  10. An Investigation of Alternative Methods for Measuring Static Pressure of Unitary Air Conditioners and Heat Pumps

    E-Print Network [OSTI]

    Wheeler, Grant Benson

    2013-08-12T23:59:59.000Z

    This project was created to address an important issue currently faced by test facilities measuring static pressure for air-conditioning and heat pumps. Specifically, ASHRAE Standard 37, the industry standard for test setup, requires an outlet duct...

  11. Monitoring the Performance of a Residential Central Air Conditioner under Degraded Conditions on a Test Bench

    E-Print Network [OSTI]

    Palani, M.; O'Neal, D. L.; Haberl, J. S.

    1992-01-01T23:59:59.000Z

    enthalpies at six locations were calculated using the refrigerant property calculation program developed by Kartsounes[26]. Air-side enthalpy, humidity and specific volume were calculated by a psychrometric program developed at the Energy Systems Laboratory... procedure based on measurement of refrigerant and air side temperatures. n TABLE OF CONTENTS CHAPTER Page I INTRODUCTION 1 E LITERATURE REVIEW 3 Service and failure patterns 3 Degradation studies 4 HI MODEL DEVELOPMENT 6 Theory of operation 6 Degraded...

  12. Dirty Air Conditioners: Energy Implications of Coil Fouling Jeffrey Siegel, Lawrence Berkeley National Laboratory/ UC Berkeley

    E-Print Network [OSTI]

    Siegel, Jeffrey

    . For typical residential heat pump and air conditioning Residential Buildings: Technologies, Design heat pump condenser coil will foul sufficiently to cause a 20 % reduction in performance over a 4 to 7 is based on a model of heat exchanger fouling that we developed specifically for residential heat

  13. Dirty Air Conditioners: Energy Implications of Coil Fouling Jeffrey Siegel, Lawrence Berkeley National Laboratory/ UC Berkeley

    E-Print Network [OSTI]

    . For typical residential heat pump and air conditioning #12;systems, they predict a 10 ­ 25 % average energy heat pump condenser coil will foul sufficiently to cause a 20 % reduction in performance over a 4 to 7 is based on a model of heat exchanger fouling that we developed specifically for residential heat

  14. Improving the Operating Efficiency of Packaged Air Conditioners and Heat Pumps

    SciTech Connect (OSTI)

    Katipamula, Srinivas; Wang, Weimin; Vowles, Mira

    2014-03-10T23:59:59.000Z

    This article discusses several control strategies that can significantly reduce energy consumption associated with packaged rooftop units RTUs). Although all of the considered strategies are widely used in built-up air-handing units, they are not commonly used in existing RTUs. Both simulation and field evaluations show that adding these control strategies to existing RTUs can reduce their energy consumption by between 30% and 60%.

  15. The Impact of Residential Air Conditioner Charging and Sizing on Peak Electrical Demand

    E-Print Network [OSTI]

    Neal, L.; O'Neal, D. L.

    rebate and maintenance programs for many years. The purpose of these programs was to improve the efficiency of the stock of air conditioning equipment and provide better demand-side management. This paper examines the effect of refrigerant charging... increases. The cooling load is assumed to be zero at an outdoor temperature of 70 F. This would assume an internal heat gain equal to approximately 8 F if the thermostat setting is at 78 F. The house load is also assumed to be equal to the test unit...

  16. ISSUANCE 2015-05-01: Commercial Package Air Conditioners and Commercial

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy ChinaofSchaefer To:Department ofOralGovernment VehicleStandards forCommittee:Warm Air

  17. Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study

    SciTech Connect (OSTI)

    Piotr A. Domanski; W. Vance Payne

    2002-10-31T23:59:59.000Z

    The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The performance degradation of R410A at higher temperatures was greater than R22. However, the R22 and R410A systems both operated normally during all tests. Visual observations of the R410A system provided no indication of vibrations or TXV hunting at high ambient outdoor test conditions with the compressor operating in the transcritical regime.

  18. Analysis on the energy efficiency of variable-frequency air conditioners (Hitachi models as an example) Jim Jr-Min Lin 2014.09.26

    E-Print Network [OSTI]

    Analysis on the energy efficiency of variable-frequency air conditioners (Hitachi models (Max) Energy Efficiency @min load Energy Efficiency @Max load kW kW kW kW W/W W/W RAS-22NB 1.00 3.20 0 Efficiency @min load Energy Efficiency @Max load kW kW kW kW W/W W/W RAM-5FNS(B) - 12.5 - 2.91 - 4.3 RAM-6FNS

  19. 2015-02-13 Issuance: Energy Conservation Standards for Portable Air Conditioners; Notice of Public Meeting and Availability of the Preliminary Technical Support Document

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register notice of public meeting regarding energy conservation standards for portable air conditioners, as issued by the Deputy Assistant Secretary for Energy Efficiency on February 13, 2015. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

  20. A Novel, Low-Cost, Reduced-Sensor Approach for Providing Smart Renote Monitoring and Diagnostics for Packaged Air Conditioners and Heat Pumps

    SciTech Connect (OSTI)

    Brambley, Michael R.

    2009-09-01T23:59:59.000Z

    This report describes conceptually an approach to providing automated remote performance and conditioning monitoring and fault detection for air conditioners and heat pumps that shows great promise to reduce the capital and installation costs of such systems from over $1000 per unit to $200 to $400 per unit. The approach relies on non-intrusive electric load monitoring (NIELM) to enable separation of the power use signals of compressors and fans in the air conditioner or heat pump. Then combining information on the power uses and one or two air temperature measurements, changes in energy efficiency and occurrence of major faults would be detected. By decreasing the number of sensors used from between ten and twenty in current diagnostic monitoring systems to three for the envisaged system, the capital cost of the monitoring system hardware and the cost of labor for installation would be decreased significantly. After describing the problem being addressed and the concept for performance monitoring and fault detection in more detail, the report identifies specific conditions and faults that the proposed method would detect, discusses specific needs for successful use of the NIELM approach, and identifies the major elements in the path from concept to a commercialized monitoring and diagnostic system.

  1. Proceedings of Healthy Buildings 2009 Paper 474 Impacts of HVAC Filtration on Air-Conditioner Energy Consumption in

    E-Print Network [OSTI]

    Siegel, Jeffrey

    -Conditioner Energy Consumption in Residences Brent Stephens1,* , Atila Novoselac1 and Jeffrey A. Siegel1 1, a greater pressure drop will generally lead to increased energy consumption (e.g., Fisk et al., 2002 The University of Texas at Austin, USA * Corresponding email: stephens.brent@mail.utexas.edu SUMMARY The use

  2. Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges

    E-Print Network [OSTI]

    Phadke, Amol

    2014-01-01T23:59:59.000Z

    Heating, Refrigerating and Air-Conditioning Engineers, 2012.EER for the base case air conditioning unit is taken as the

  3. An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with Capillary Tube Expansion 

    E-Print Network [OSTI]

    Farzad, M.; O'Neal, D. L.

    1988-01-01T23:59:59.000Z

    ] conducted a laboratory test to determine the performance of a 3-ton air-to-air heat pump as a function of R-22 refrigerant charge in the heating mode. The tests were conducted with 50?F outdoor air and 70?F indoor air temperatures. The test unit did....8) 11 Figure 2.5 - Coefficient of Performance as a Function of Refrigerant Charge (adopted from ref.8) 12 A. A. Domingorena and S. J. Ball [9] studied the performance of a selected three-ton air-to-air heat pump in the heating mode at Oak Ridge...

  4. PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976

    E-Print Network [OSTI]

    Dao, K.

    2010-01-01T23:59:59.000Z

    from flat-plate solar collectors and use air cooling forwith flat-plate solar collectors and air cooling; namely,from flat-plate solar collectors. Absorption refrigeration

  5. Solar-Powered, Liquid-Desiccant Air Conditioner for Low-Electricity Humidity Control: Report and Summary Report

    SciTech Connect (OSTI)

    Dean, J.; Kozubal, E.; Herrmann, L.; Miller, J.; Lowenstein, A.; Barker, G.; Slayzak, S.

    2012-11-01T23:59:59.000Z

    The primary objective of this project was to demonstrate the capabilities of a new high-performance, liquid-desiccant dedicated outdoor air system (DOAS) to enhance cooling efficiency and comfort in humid climates while substantially reducing electric peak demand at Tyndall Air Force Base (AFB), which is 12 miles east of Panama City, Florida.

  6. Development of empirical temperature and humidity-based degraded-condition indicators for low-tonnage air conditioners

    E-Print Network [OSTI]

    Watt, James Bonner

    1997-01-01T23:59:59.000Z

    of conditions resulting in inefficient operation as reported by Neal from a survey of 10 residential air-conditioning units (Neal 1986, 1987). Problem Refri erant over-char e Refri erant under-char e Eva orator airflow inade uate Ev orator airflow too hi... wheel Freon char e Com onent Condition ratin Poor to Fair Poor to Fair Poor to Fair Return-air lenum Condensate s stem Su 1 air ducts Eva orator Coils Filter Controls Poor to Fair Poor to Avera e Fair to Avera e Fair to Good Fair to Good...

  7. Development of Temperature and Humidity-Based Indicators for Diagnosing Problems in Low Tonnage, Split System Air Conditioners 

    E-Print Network [OSTI]

    Watt, J. B.; O'Neal, D. L.; Haberl, J. S.

    1998-01-01T23:59:59.000Z

    and businesses. The unit had heat pump operation capability, however, the heat pump mode was not used in these tests. The entire assembly is shown in Figure 2. The evaporator section was connected to the condensing unit with copper tubing. The liquid... ): preprint. Lewis, J. 1987. Survey of residential air-to-air heat pump service life and maintenance issues. ASHRAE Transactions, 93( 1): 1 1 1 1 - 1 127. Lloyd, G.R., 1994. T.E.C.H. method lesson series. 27227 Weddel, Trenton, MI. McQuiston, F.C. and J...

  8. An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with a Thermal Expansion Valve 

    E-Print Network [OSTI]

    Farzad, M.; O'Neal, D. L.

    1989-01-01T23:59:59.000Z

    and was exhausted by the unit fan back into the room through the outdoor coil. PSYCHROMETRIC ROOMS The psychrometric rooms could simulate all testing conditions required for air conditioning and heat pump performance testing. Dew point and room temperatures could..., Including Heat Pumps (1979)[7]. The entering dry bulb temperature for the outdoor coil for steady state and cyclic tests was 82? +/-0.3 F DB and 20% relative humidity. The steady state tests were repeated for outdoor temperatures of 90?, 95?, and 100?F...

  9. Effect of refrigerant charge, duct leakage, and evaporator air flow on the high temerature performance of air conditioners and heat pumps

    E-Print Network [OSTI]

    Rodriguez, Angel Gerardo

    1995-01-01T23:59:59.000Z

    evaporator airflow, and return air leakage from hot attic spaces. There were five sets of tests used for this research: two of them for the charging tests, two for the reduced evaporator airflow, and one for the return air leakage tests. For the charging...

  10. 13 EER Window Air Conditioner

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: The Future of BadTHE U.S. DEPARTMENT OF ENERGY'EliseConferencePRESENTATIONSof13

  11. Future Air Conditioning Energy Consumption in Developing Countries and what can be done about it: The Potential of Efficiency in the Residential Sector

    E-Print Network [OSTI]

    McNeil, Michael A.; Letschert, Virginie E.

    2008-01-01T23:59:59.000Z

    an air conditioner for the first time, or by replacements ofair conditioner lifetime. Each retirement generates another replacementreplacements. Step 1 is described in detail in the section called Forecasting Air Conditioner

  12. Future Air Conditioning Energy Consumption in Developing Countries and what can be done about it: The Potential of Efficiency in the Residential Sector

    E-Print Network [OSTI]

    McNeil, Michael A.; Letschert, Virginie E.

    2008-01-01T23:59:59.000Z

    an air conditioner for the first time, or by replacements ofair conditioner lifetime. Each retirement generates another replacementand replacements. Step 1 is described in detail in the section called Forecasting Air Conditioner

  13. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology

    SciTech Connect (OSTI)

    Not Available

    1993-11-01T23:59:59.000Z

    The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

  14. Air-Con International: Noncompliance Determination and Proposed...

    Energy Savers [EERE]

    Notice of Noncompliance Determination to Air-Con International finding that a variety of central air conditioners and air conditioning heat pumps distributed under the Air-Con...

  15. DOE Requires Air-Con International to Cease Sales of Inefficient...

    Broader source: Energy.gov (indexed) [DOE]

    Requires Air-Con International to Cease Sales of Inefficient Air Conditioners and Proposes Penalties DOE Requires Air-Con International to Cease Sales of Inefficient Air...

  16. Homeowner's Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet), Building America Case Study: Technology Solutions for Existing Homes, Building Technologies Office (BTO)

    SciTech Connect (OSTI)

    Not Available

    2013-06-01T23:59:59.000Z

    This fact sheet offers a step-by-step guide to proper installation of window air conditioning units, in order to improve efficiency and comfort for homeowners.

  17. CX-004924: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    lnfinia - Stirling Air Conditioner (StAC) for Compact CoolingCX(s) Applied: B3.6Date: 08/05/2010Location(s): Kennewick, WashingtonOffice(s): Advanced Research Projects Agency - Energy

  18. Air Cooling Technology for Power Electronic Thermal Control

    Broader source: Energy.gov (indexed) [DOE]

    air conditioners Need to understand system trade-offs driven by air source local thermal environment which are influenced by inverter location National Renewable Energy Laboratory...

  19. PROC. 27th STACS, 2010 Submitted to the Symposium on Theoretical Aspects of Computer Science

    E-Print Network [OSTI]

    Niedermeier, Rolf

    .stacs-conf.org REFLECTIONS ON MULTIVARIATE ALGORITHMICS AND PROBLEM PARAMETERIZATION ROLF NIEDERMEIER Institut f steadily grown over the last years. We survey and discuss how parameterized complexity analysis naturally develops into the field of multivariate algorithmics. Correspondingly, we describe how to perform

  20. EVALUATION OF A NEW SOLAR AIR CONDITIONER

    E-Print Network [OSTI]

    · Benefits to California · Overall Technology Assessment · Appendices o Appendix A: Final Report (under-16 Grant Funding: $74,547 Term: February 2001 ­ June 2003 PIER Subject Area: Renewable Energy Technologies/Agricultural/Water End-Use Energy Efficiency · Renewable Energy Technologies · Environmentally-Preferred Advanced

  1. Natural Gas Heat Pump and Air Conditioner

    Broader source: Energy.gov [DOE]

    Lead Performer: Thermolift - Stony Brook, NY Partners: -- New York State Energy Research & Development Authority - Albany, NY -- Stony Brook University - Stony Brook, NY -- Oak Ridge National Laboratory - Oak Ridge, TN -- National Grid - Washington, DC -- Applied Thermodynamic Apparatus (ATA) - Ann Arbor, MI -- Fala Technologies - Kingston, NY -- LoDolce - Saugerties, NY

  2. Common Air Conditioner Problems | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the YouTube platformBuildingCoal CombustionSmart Gridfor Federal Facilities

  3. Common Air Conditioner Problems | Department of Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625govInstrumentstdmadapInactiveVisiting theCommercialization and Innovation The Commercialization andCommittees

  4. Central Air conditioners | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model, click here.Telluric Survey asWest, NewCenterville, Ohio: Energy

  5. Tips: Air Conditioners | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov. Are you sure you want toworldPower 2010 1 TNews & Solar Solar How

  6. Room Air Conditioners | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOrigin ofEnergy at Waste-to-Energy usingofRetrofittingFundA l i c eRooftop UnitRooftopRoom

  7. Room Air Conditioners | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic2 OPAM615_CostNSAR -DepartmentRetailEnergy Role of Modeling andSoft Costs

  8. Maintaining Your Air Conditioner | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122Commercial602 1,39732on ArmedManufacturingJunePracticeShipping GoalMailDepartment

  9. Cromer Cycle Air Conditioner | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"Wave theJuly 30,Crafty Gifts for theof EnergyRev. 1) |

  10. DOE Investigates Possible Air Conditioner Efficiency Violations |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"Wave theJulyD&DDepartment of Energy IdentifiesforDepartment

  11. Maintaining Your Air Conditioner | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking ofOil & Gas »ofMarketing |PrepareMOJAVE

  12. Tips: Air Conditioners | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMayDepartmentTest for PumpingThe| Department of

  13. Room Air Conditioners | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro Industries Pvt Ltd Jump to: navigation,MazeOhio:Ohio:RockwallRolling

  14. Room Air Conditioners | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently AskedEnergy SmallImplementing theFinancing » Financing, 2003Ronald A.Soft Costs

  15. Future Air Conditioning Energy Consumption in Developing Countries and what can be done about it: The Potential of Efficiency in the Residential Sector

    E-Print Network [OSTI]

    McNeil, Michael A.; Letschert, Virginie E.

    2008-01-01T23:59:59.000Z

    G. Henderson (2005) Home air conditioning in Europe – howhigher growth in Indian air conditioner saturation duringand A.A. Pavlova ( 2003). Air conditioning market saturation

  16. Low-noise pulse conditioner

    DOE Patents [OSTI]

    Bird, David A. (Oak Ridge, TN)

    1983-01-01T23:59:59.000Z

    A low-noise pulse conditioner is provided for driving electronic digital processing circuitry directly from differentially induced input pulses. The circuit uses a unique differential-to-peak detector circuit to generate a dynamic reference signal proportional to the input peak voltage. The input pulses are compared with the reference signal in an input network which operates in full differential mode with only a passive input filter. This reduces the introduction of circuit-induced noise, or jitter, generated in ground referenced input elements normally used in pulse conditioning circuits, especially speed transducer processing circuits.

  17. HEATING, AIR-CONDITIONING AND REFRIGERATION DISTRIBUTORS INTERNATIONAL...

    Broader source: Energy.gov (indexed) [DOE]

    OE Framework Document and Stakeholder Meeting regarding the Enforcement of the updated Energy Conservation Standards for Air Conditioners, Furnaces and Heat Pumps. DOE EX Parte...

  18. Low-noise pulse conditioner

    DOE Patents [OSTI]

    Bird, D.A.

    1981-06-16T23:59:59.000Z

    A low-noise pulse conditioner is provided for driving electronic digital processing circuitry directly from differentially induced input pulses. The circuit uses a unique differential-to-peak detector circuit to generate a dynamic reference signal proportional to the input peak voltage. The input pulses are compared with the reference signal in an input network which operates in full differential mode with only a passive input filter. This reduces the introduction of circuit-induced noise, or jitter, generated in ground referenced input elements normally used in pulse conditioning circuits, especially speed transducer processing circuits. This circuit may be used for conditioning the sensor signal from the Fidler coil in a gas centrifuge for separation of isotopic gaseous mixtures.

  19. Development of slotted orifice flow conditioner

    E-Print Network [OSTI]

    Ihfe, Larry Michael

    1994-01-01T23:59:59.000Z

    for the two flow conditioners. A baseline Co was also plotted for comparative purposes. 24 RESULTS LDA Veloci Profile and Turbulence Intensi Anal sis The velocity profile and turbulence intensity measurements obtained using the LDA are shown in figures...

  20. Optimization of Air Conditioning Cycling

    E-Print Network [OSTI]

    Seshadri, Swarooph

    2012-10-19T23:59:59.000Z

    on a 3-ton residential air conditioner are then presented to intuitively understand the effect of expansion valve and evaporator fan cycling in a real system. A real time optimization method is explored and the feasibility, recommendations for a...

  1. Symposium on Theoretical Aspects of Computer Science 2010 (Nancy, France), pp. 17-32 www.stacs-conf.org

    E-Print Network [OSTI]

    Wichmann, Felix

    .stacs-conf.org REFLECTIONS ON MULTIVARIATE ALGORITHMICS AND PROBLEM PARAMETERIZATION ROLF NIEDERMEIER Institut f steadily grown over the last years. We survey and discuss how parameterized complexity analysis naturally develops into the field of multivariate algorithmics. Correspondingly, we describe how to perform

  2. 2014-03-06 Issuance: Test Procedures for Packaged Terminal Air...

    Broader source: Energy.gov (indexed) [DOE]

    3-06 Issuance: Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps; Notice of Proposed Rulemaking 2014-03-06 Issuance: Test Procedures for...

  3. DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Summit Manufacturing, and Advanced Distributor Products -- must stop distributing 61 heat pump models and 1 air conditioner model that DOE has determined do not comply with...

  4. Field Measurements of Efficiency and Duct Effectiveness in Residential Forced Air Distributions Systems

    E-Print Network [OSTI]

    Jump, D.A.

    2011-01-01T23:59:59.000Z

    power for air conditioning, heat pumps and electricwith 13 air conditioners, eight heat pumps (one house hadPre Post * A C : air conditioning, HP : heat pump, GF : gas

  5. An air-to-air heat pump (COP-3.11 at 470 F (8.30C)) run alternately with an electric-resistance water

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    -resistance water heater and a desuperheater water heater was tested under field conditions at a site near Knoxville. One way : . '-~~ .~ Is to use a desuperheater. or heat recovery water heater, with air conditioners are offering . .. .. · ~'*desuperheaier water heaters (DSWI | as options for their central air conditioners

  6. Ventilation Air Preconditioning Systems

    E-Print Network [OSTI]

    Khattar, M.; Brandemuehl, M. J.

    1996-01-01T23:59:59.000Z

    simply and cost-effectively with a dual path arrangement that treats and controls the ventilation air independently of the recirculation air. The Electric Power Research Institute (EPRI)--the nonprofit R&D arm of the electric utility industry... particular type of application. EPRI is developing variations of the dual path concept to meet different reeofit and new construction markets. Figure 6. Ventilation Air Conditioner as a Separate Unit EPRVCALMAC System: Separate Unit for Ventilation Air...

  7. About Nuccio Heating & Air Headquartered in Tampa, Florida, Nuccio Heating & Air serves

    E-Print Network [OSTI]

    Fisher, Kathleen

    a customer say, `you installed my first air conditioner - yourself!'" Nuccio Heating & Air serves commercialAbout Nuccio Heating & Air Headquartered in Tampa, Florida, Nuccio Heating & Air serves commercial ­ the majority being highly mobile ­ sell and service heating and air conditioning systems for the company

  8. air conditioners water: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    89. a. Heat flux QA Tx T (QA) x (5000 )...( . . ' the necessary pressure head is z + p(g) 105 + 6523210000 111.65 m. c. Pumping power (gz + p Zevenhoven,...

  9. Determining benefits and costs of improved central air conditioner efficiencies

    E-Print Network [OSTI]

    Rosenquist, G.

    2010-01-01T23:59:59.000Z

    Administration, Annual Energy Outlook 2000, December, 1999.trends from EIA's Annual Energy Outlook 2000 (AE02000) were

  10. An Analysis of Efficiency Improvements in Room Air Conditioner

    E-Print Network [OSTI]

    O'Neal, D. L.; Penson, S. B.

    1988-01-01T23:59:59.000Z

    and Evaporator Models 3.2 Model Output 3.4 Conclusions and Model Selection 3.4 References 3.5 4 MODEL DEVELOPMENT 4.1 Identification of Changes 4.1 Subcooler 4.2 Condensate Spray 4.2 Roughened Tubes 4.7 Capillary Tube Model Modifications 4.7 Correlations 4....7 Subcooler 4.8 Wet Condenser 4.10 Roughened Tubes 4.11 Reversing Valve 4 .12 Capillary Tube Model 4.12 CHAPTER PAGE Coding of Changes 4.16 Subcooler 4.17 Water Spray 4.17 Roughened Tubes 4.18 Reversing Valve 4.18 Capillary Tube 4.18 References 4.19 5 MODEL...

  11. Desiccant Moisture Exchange for Dehumidification Enhancement of Air Conditioners

    E-Print Network [OSTI]

    Cromer, C. J.

    1988-01-01T23:59:59.000Z

    . When a high pmpxticm of the werall load an the chiller mil is latent or misture ren~val, this new prooess PnWidee the -ty for cpera*m enerVy mavinge as well as the potenUal for reduced UXt. One l3mct.b of kdldtrrgs, ~xnnrercial and midslrtial...

  12. NREL Solves Residential Window Air Conditioner Performance Limitations (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-05-01T23:59:59.000Z

    Comprehensive performance tests lead to enhanced modeling capability and affordable methods to increase energy efficiency.

  13. Determining benefits and costs of improved central air conditioner efficiencies

    E-Print Network [OSTI]

    Rosenquist, G.

    2010-01-01T23:59:59.000Z

    of Energy-Energy Information Administration, A Look atof Energy-Energy Information Administration, 1995 Commercialof Energy-Energy Information Administration, Annual Energy

  14. Cromer Cycle Air Conditioner: A Study to Confirm Target Performance

    E-Print Network [OSTI]

    Cromer, C. J.

    2001-01-01T23:59:59.000Z

    . That evening, the wheel was removed and the duct resealed. The two days had quite similar weather and the data obtained and can provide some insight into the system operation. COMPARATIVE DATA Table 1 provides a data set for the system operating without...

  15. DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS

    E-Print Network [OSTI]

    Dao, K.

    2013-01-01T23:59:59.000Z

    ROAD BERKELEY, CALIFORNIA OBJECTIVE AND APPROACH The objective of this project is the development of absorption refrigeration systems for solar

  16. air conditioners energy: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Summary: -16 Grant Funding: 74,547 Term: February 2001 - June 2003 PIER Subject Area: Renewable Energy Technologies areas: Residential and Commercial Building...

  17. Determining benefits and costs of improved central air conditioner efficiencies

    E-Print Network [OSTI]

    Rosenquist, G.

    2010-01-01T23:59:59.000Z

    Engineers, Inc. , Energy Efficient Design of New BuildingsStandard 90.1, Energy Efficient Design of New Buildings

  18. Determining benefits and costs of improved central air conditioner efficiencies

    E-Print Network [OSTI]

    Rosenquist, G.

    2010-01-01T23:59:59.000Z

    analyze, the energy price projection, and the start year (uncertainty of projections offuture energy prices, the LCC

  19. Development of a room air conditioner design model 

    E-Print Network [OSTI]

    Penson, Steven Brad

    1988-01-01T23:59:59.000Z

    model was developed for this thesis by making major modifications to a heat pump model previously developed by Oak Ridge National Laboratory: (1) Addition of a subcooler, (2) Revision of the capillary tube model, (3) Addition of multi-grooved tubes.... Efficiency improvements are evaluated with the aid of a computer model. The model chosen for this analysis was the Oak Ridge National Laboratory (ORNL) heat pump model [5] . The ORNL Heat Pump Design Model is a FORTRAN computer program developed...

  20. Variable Speed Fan Retrofits for Computer Room Air Conditioners |

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilA group current C3EDepartmentDepartment of Energy Photo of a vapor

  1. Ductless Mini-Split Air Conditioners | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently20,000 Russian NuclearandJunetrack graphics4Dimitri Kusnezov -Purpose(FY)TheA ductless

  2. air conditioner utilizing: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Conditions - The Utility Perspective Ammi Amarnath Technical Leader, Energy Efficiency & Demand Response Program Electric Power Research Institute 3420 Hillview Avenue Palo Alto,...

  3. Central Air Conditioner Enforcement Policy Statement | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the YouTube platformBuilding RemovalCSS LetterStateDepartmentAnnounce Results of

  4. Enforcement Policy Statement: Off Mode Standards for Central Air Conditioners

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011AT&T,OfficeEnd of Year 2010 SNFEnergySession0-02 - December 23,Energy

  5. Four Central Air Conditioners Determined Noncompliant With Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport inEnergy0.pdf Flash2010-60.pdf2 DOE HydrogenPlansDecades

  6. High-Efficiency Window Air Conditioners - Building America Top Innovation |

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy ChinaofSchaefer To:Department of EnergySeacrist, Senior FellowDepartment ofDepartment

  7. Covered Product Category: Residential Central Air Conditioners | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"Wave theJuly 30, 2013DepartmentEnterprise ServersHotDepartmentof

  8. Commercial Air Conditioners and Heat Pumps | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy China U.S. DepartmentEnergy This partAs the Department ofAARP, NASUCA,The Department

  9. 13-Energy Efficiency Ratio Window Air Conditioner | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic2UraniumEnergy CityDepartment ofNuclear Information100% Cleanhe12 Days

  10. List of Room Air Conditioners Incentives | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, searchOf KilaueaInformation Other Alternative FuelEnergy Jump to:List

  11. History of the Air Conditioner | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122Commercial602 1,397 125 QDecemberBlogFEES FOIA FEESGraphicsforHead

  12. Variable Speed Fan Retrofits for Computer Room Air Conditioners

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your DensityEnergy U.S.-China Electric Vehicle and03/02 TUEValidation of Innovativeof Energy

  13. Variable Speed Fan Retrofits for Computer Room Air Conditioners |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your DensityEnergy U.S.-China Electric Vehicle and03/02 TUEValidation of Innovativeof EnergyDepartment of

  14. Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy Chinaof EnergyImpactOn July 2, 2014 in theGroupJuneThis primer on

  15. Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)

    SciTech Connect (OSTI)

    Kozubal, E.

    2013-02-01T23:59:59.000Z

    This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

  16. Radio-Frequency Beam Conditioner for Fast-Wave Free-Electron Generators of Coherent Radiation

    E-Print Network [OSTI]

    Sessler, Andrew M.

    2008-01-01T23:59:59.000Z

    to Physical Review Letters Radio-Frequency Beam ConditionerDE-AC03-76SF00098 LBL-31006 RADIO-FREQUENCY BEAM CONDITIONERIbaraki, 305, Japan. RADIO-FREQUENCY BEAM CONDITIONER FOR

  17. Cromer Cycle Air Conditioner: A Unique Air-Conditioner Desiccant Cycle to Enhance Dehumidification and Save Energy

    E-Print Network [OSTI]

    Cromer, C. J.

    2000-01-01T23:59:59.000Z

    for the AC system. The desiccant wheel was slid into the duct system and a test run completed. The wheel was then removed from the system, the ducts resealed, and an additional test run completed. By this alternation method, three runs with the wheel...

  18. High Energy Efficiency Air Conditioning

    SciTech Connect (OSTI)

    Edward McCullough; Patrick Dhooge; Jonathan Nimitz

    2003-12-31T23:59:59.000Z

    This project determined the performance of a new high efficiency refrigerant, Ikon B, in a residential air conditioner designed to use R-22. The refrigerant R-22, used in residential and small commercial air conditioners, is being phased out of production in developed countries beginning this year because of concerns regarding its ozone depletion potential. Although a replacement refrigerant, R-410A, is available, it operates at much higher pressure than R-22 and requires new equipment. R-22 air conditioners will continue to be in use for many years to come. Air conditioning is a large part of expensive summer peak power use in many parts of the U.S. Previous testing and computer simulations of Ikon B indicated that it would have 20 - 25% higher coefficient of performance (COP, the amount of cooling obtained per energy used) than R-22 in an air-cooled air conditioner. In this project, a typical new R-22 residential air conditioner was obtained, installed in a large environmental chamber, instrumented, and run both with its original charge of R-22 and then with Ikon B. In the environmental chamber, controlled temperature and humidity could be maintained to obtain repeatable and comparable energy use results. Tests with Ikon B included runs with and without a power controller, and an extended run for several months with subsequent analyses to check compatibility of Ikon B with the air conditioner materials and lubricant. Baseline energy use of the air conditioner with its original R-22 charge was measured at 90 deg F and 100 deg F. After changeover to Ikon B and a larger expansion orifice, energy use was measured at 90 deg F and 100 deg F. Ikon B proved to have about 19% higher COP at 90 deg F and about 26% higher COP at 100 deg F versus R-22. Ikon B had about 20% lower cooling capacity at 90 deg F and about 17% lower cooling capacity at 100 deg F versus R-22 in this system. All results over multiple runs were within 1% relative standard deviation (RSD). All of these values agree well with previous results and computer simulations of Ikon B performance versus R-22. The lower cooling capacity of Ikon B is not a concern unless a particular air conditioner is near its maximum cooling capacity in application. Typically, oversized A/C systems are installed by contractors to cover contingencies. In the extended run with Ikon B, which lasted about 4.5 months at 100 deg F ambient temperature and 68% compressor on time, the air conditioner performed well with no significant loss of energy efficiency. Post-run analysis of the refrigerant, compressor lubricant oil, compressor, compressor outlet tubing, and the filter/dryer showed minor effects but nothing that was considered significant. The project was very successful. All objectives were achieved, and the performance of Ikon B indicates that it can easily be retrofitted into R-22 air conditioners to give 15 - 20% energy savings and a 1 - 3 year payback of retrofit costs depending on location and use. Ikon B has the potential to be a successful commercial product.

  19. A PLASMA CHANNEL BEAM CONDITIONER FOR A FREE ELECTRON LASER

    E-Print Network [OSTI]

    Wurtele, Jonathan

    A PLASMA CHANNEL BEAM CONDITIONER FOR A FREE ELECTRON LASER G. Penn , A.M. Sessler, J.S. Wurtele of free electron lasers (FELs) can be dramatically improved. Under certain con- ditions, the FEL can transverse action and energy, has been shown to be advantageous for free electron laser (FEL) performance [1

  20. Spring is in the Air and so is a Plethora of Pollen Dr. Joan Bradshaw, County Extension Director

    E-Print Network [OSTI]

    Jawitz, James W.

    and skin. Use air filters and clean regularly, or run an air conditioner and change the air filterSpring is in the Air and so is a Plethora of Pollen Dr. Joan Bradshaw, County Extension Director, Suite 1 Lecanto, FL 34461 Springtime is in the air in Citrus County with its glorious weather

  1. Commissioning Tools for Heating/Cooling System in Residence - Verification of Floor Heating System and Room Air Conditioning System Performance 

    E-Print Network [OSTI]

    Miura, H.; Hokoi, S.; Iwamae, A.; Umeno, T.; Kondo, S.

    2004-01-01T23:59:59.000Z

    Tools of evaluating the performance of floor heating and room air conditioner are examined as a commissioning tool. Simple method is needed to check these performance while in use by residents, because evaluation currently requires significant time...

  2. Commissioning Tools for Heating/Cooling System in Residence - Verification of Floor Heating System and Room Air Conditioning System Performance

    E-Print Network [OSTI]

    Miura, H.; Hokoi, S.; Iwamae, A.; Umeno, T.; Kondo, S.

    2004-01-01T23:59:59.000Z

    Tools of evaluating the performance of floor heating and room air conditioner are examined as a commissioning tool. Simple method is needed to check these performance while in use by residents, because evaluation currently requires significant time...

  3. BEETIT: Building Cooling and Air Conditioning

    SciTech Connect (OSTI)

    None

    2010-09-01T23:59:59.000Z

    BEETIT Project: The 14 projects that comprise ARPA-E’s BEETIT Project, short for “Building Energy Efficiency Through Innovative Thermodevices,” are developing new approaches and technologies for building cooling equipment and air conditioners. These projects aim to drastically improve building energy efficiency and reduce greenhouse gas emissions such as carbon dioxide (CO2) at a cost comparable to current technologies.

  4. King Air flight RICO 2004/12/13 page 1 King Air N2UW flight report for December 13, 2004

    E-Print Network [OSTI]

    Vali, Gabor

    repair of the air conditioner on the aircraft, a test flight was needed and was to be transformedKing Air flight ­ RICO ­ 2004/12/13 page 1 King Air N2UW flight report for December 13, 2004 Crew: Drew, Vali, Oolman, Glover After

  5. Use of chlorofluorocarbons in refrigeration, insulation and mobile air conditioning in the USA*

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    FILE COPY DO NOT REMOVE Use of chlorofluorocarbons in refrigeration, insulation and mobile air in refrigeration equipment and mobile air conditioners, or as the blowing agent in foam insulations. When again accounted for _ 40 %of the potential risk to the environment. Refrigeration, mobile air

  6. Investigating the Performance of Solar Air Conditioning Motivation/Background Findings

    E-Print Network [OSTI]

    -thermal collectors We investigated 3 types of solar cooling technologies: · Air conditioning consumes 10% of all collector size is a critical limiting factor of solar air conditioners · High driving temperatureInvestigating the Performance of Solar Air Conditioning Motivation/Background Findings Two Building

  7. Air Conditioning with Magnetic Refrigeration : An Efficient, Green Compact Cooling System Using Magnetic Refrigeration

    SciTech Connect (OSTI)

    None

    2010-09-01T23:59:59.000Z

    BEETIT Project: Astronautics is developing an air conditioning system that relies on magnetic fields. Typical air conditioners use vapor compression to cool air. Vapor compression uses a liquid refrigerant to circulate within the air conditioner, absorb the heat, and pump the heat out into the external environment. Astronautics’ design uses a novel property of certain materials, called “magnetocaloric materials”, to achieve the same result as liquid refrigerants. These magnetocaloric materials essentially heat up when placed within a magnetic field and cool down when removed, effectively pumping heat out from a cooler to warmer environment. In addition, magnetic refrigeration uses no ozone-depleting gases and is safer to use than conventional air conditioners which are prone to leaks.

  8. Comparing Mainframe and Windows Server Transactions per kWh

    E-Print Network [OSTI]

    Narasayya, Vivek

    ..................................................................................................................................15 Air Conditioner (Heat Pump) Efficiency Units

  9. DOE Takes Action to Stop the Sales of Air-Con Air Conditioner...

    Office of Environmental Management (EM)

    and Proposed Civil Penalty (pdf - 234kb). Follow the Department of Energy on Facebook, Twitter, Youtube and Flickr. Follow Secretary Chu on his Facebook page. Media...

  10. The Effect of Reduced Evaporator Air Flow on the Performance of a Residential Central Air Conditioner

    E-Print Network [OSTI]

    Palani, M.; O'Neal, D.; Haberl, J.

    COMPONENT SPECIFICATION COMPRESSOR Single Speed, 230 V, SOp A...A 17.1 and LRA 79.0 amps Employs internal line breaker(IOL) Internal Pressure Relief OPR) opens at 350 psig difference STRAINER DRIER Discharge line WiUl sweat fitting 8 cubic inch, 3/8 X... for electrical controls and miscellaneous electrical devices represented 31.4% of the total number of failures and refrigerant leaks constituted 17.2% of the total failure. The failure rates of compressors was 13.5% and outdoor fans was about I 1.5%. Lewis...

  11. DOE Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613PortsmouthBartlesvilleAbout »DepartmentLaboratory |and Loan Recipients | Departmentto

  12. Establish the Commercial Pacakge Air Conditioners and Commercial Warm Air Furnaces WG

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: The Future of Bad CholesteroliManage Presentation3 DATE: March 14,62008

  13. Air conditioning system

    DOE Patents [OSTI]

    Lowenstein, Andrew; Miller, Jeffrey; Gruendeman, Peter; DaSilva, Michael

    2005-02-01T23:59:59.000Z

    An air conditioner comprises a plurality of plates arranged in a successively stacked configuration with portions thereof having a spaced apart arrangement, and defining between successive adjacent pairs of plates at the spaced apart portions a first and second series of discrete alternating passages wherein a first air stream is passed through the first series of passages and a second air stream is passed through the second series of passages; and said stacked configuration of plates forming integrally therewith a liquid delivery means for delivering from a source a sufficient quantity of a liquid to the inside surfaces of the first series of fluid passages in a manner which provides a continuous flow of the liquid from a first end to a second end of the plurality of plates while in contact with the first air stream.

  14. Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy

    E-Print Network [OSTI]

    Fuller, Merrian C.

    2011-01-01T23:59:59.000Z

    water heater replacement, air conditioner replacement, solarwater heater replacement, air conditioner replacement, solar

  15. Delivering Energy Efficiency to Middle Income Single Family Households

    E-Print Network [OSTI]

    Zimring, Mark

    2012-01-01T23:59:59.000Z

    water heater replacement, air conditioner Assumptions behindreplacements (e.g. , furnace, water heater, air conditioner,

  16. Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy

    E-Print Network [OSTI]

    Fuller, Merrian C.

    2011-01-01T23:59:59.000Z

    replacement, air conditioner replacement, solar thermalreplacement, air conditioner replacement, solar thermal

  17. Market and behavioral barriers to energy efficiency: A preliminary evaluation of the case for tariff financing in California

    E-Print Network [OSTI]

    Fujita, K. Sydny

    2012-01-01T23:59:59.000Z

    Central Air Conditioners and Heat Pumps. ” Department ofrecent central air conditioner and heat pump purchasers only

  18. Classroom Vocabulary Classroom Vocabulary [msamiati wa darasani

    E-Print Network [OSTI]

    ] [wall clock] [map / maps] [air conditioner / air conditioners] [picture / pictures] [drawing / drawings

  19. Flow conditioner for fuel injector for combustor and method for low-NO.sub.x combustor

    DOE Patents [OSTI]

    Dutta, Partha; Smith, Kenneth O.; Ritz, Frank J.

    2013-09-10T23:59:59.000Z

    An injector for a gas turbine combustor including a catalyst coated surface forming a passage for feed gas flow and a channel for oxidant gas flow establishing an axial gas flow through a flow conditioner disposed at least partially within an inner wall of the injector. The flow conditioner includes a length with an interior passage opening into upstream and downstream ends for passage of the axial gas flow. An interior diameter of the interior passage smoothly reduces and then increases from upstream to downstream ends.

  20. Calendar Year 2008 Program Benefits for ENERGY STAR Labeled Products

    E-Print Network [OSTI]

    Homan, GregoryK

    2010-01-01T23:59:59.000Z

    air cleaners Room air conditioners Scanners Servers Set-topBoilers • Central Air Conditioners and Air-Source HeatHeat Pump -Central Air Conditioner -Gas Furnace -Oil

  1. Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement

    E-Print Network [OSTI]

    Bode, Josh

    2013-01-01T23:59:59.000Z

    measurements using smart meter household data produce theof program households. Smart meters lower the cost of usingsample sizes with smart meter data can be far larger than

  2. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    L ABORATORY China Energy Efficiency Round Robin TestingNeed to Improve the Energy Efficiency of Energy Consumingfor Implementing the China Energy Efficiency Label System (

  3. Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement

    E-Print Network [OSTI]

    Bode, Josh

    2013-01-01T23:59:59.000Z

    regions. In addition, the SCADA was not available for allData Real Time Visibility SCADA 5 minutes or less Limited

  4. Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement

    E-Print Network [OSTI]

    Bode, Josh

    2013-01-01T23:59:59.000Z

    of California Statewide Aggregator Demand Response Programs.Analysis of AMP Aggregator Demand Response Program. Preparedof California Statewide Aggregator Demand Response Programs.

  5. An Analysis of Efficiency Improvements in Residential Sized Heat Pumps and Central Air Conditioners

    E-Print Network [OSTI]

    O'Neal, D. L.; Boecker, C. L.; Penson, S. B.

    1986-01-01T23:59:59.000Z

    ) Increased tube rows 3.1 1C) Increased fin density 3.2 ID) Increased heat transfer coefficient 3.2 IE) Increased parallel circuits 3.2 2) Decreased Compressor Size 3.2 3) Increased Combined Fan and Motor Efficiency 3.2 4) Demand Defrost Control Systems (Heat... Pumps Only) 3.3 5) High Efficiency Compressors 3.3 6) Two Speed Compressors 3.3 References 3.4 iii CHAPTER PAGE 4 CONVENTIONAL DESIGN IMPROVEMENTS: RESULTS 4.1 Heat Pumps 4.1 Baseline Units 4.2 Final Conventional Designs 4.7 3 Ton Split Systems 4.7 3 Ton...

  6. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01T23:59:59.000Z

    its integration. In the DOE’s energy model which was used toSources The energy efficiency simulation model used in thiss Bottom Up Energy Analysis System (BUENAS) model (McNeil et

  7. Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners

    E-Print Network [OSTI]

    McNeil, Michael A.; Iyer, Maithili

    2008-01-01T23:59:59.000Z

    the current cost of production of 3.5 Rs per kWh. It isthe average cost of production to be 3.50 Rs. per kWh, or $the cost of production significantly at 4.80 Rs. per kWh. As

  8. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    further passed the Energy Efficiency (Labeling of Products)L ABORATORY China Energy Efficiency Round Robin TestingNeed to Improve the Energy Efficiency of Energy Consuming

  9. Determination of the Transient Dehumidification Characteristics of High Efficiency Central Air Conditioners

    E-Print Network [OSTI]

    Katipamula, S.; O'Neal, D. L.; Somasundaram, S.

    1987-01-01T23:59:59.000Z

    Seasonal Energy Efficiency Ratio SHR Sensible Heat Ratio TOCZ Time Outside the Comfort Zone TMY Typical Meteorological Year TRNSYS TRaNsient SYstem Simulation ii SUMMARY A series of tests were performed to assesses the dehumidifying performance... DEVELOPMENT OF NEW ROUTINES 12 A. HVAC CONTROL MODULE 12 B. POST-PROCESSING OF THE TRNSYS OUTPUT 13 6 SELECTION OF TEST DAYS 14 7 BASE CASE 19 A. EVALUATION OF THE DESIGN LOAD 19 B. EVALUATION OF THE 14 CAC UNITS FOR BASE CASE ... 20 C. DISCUSSION OF BASE CASE...

  10. Analysis of Efficiency Standards for Air Conditioners, Heat Pumps, and Other Products

    Reports and Publications (EIA)

    2002-01-01T23:59:59.000Z

    A series of analyses showing the impacts of each of the selected provisions of the bills on energy supply, demand, and prices, macroeconomic variables where feasible, import dependence, and emissions.

  11. Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement

    E-Print Network [OSTI]

    Bode, Josh

    2013-01-01T23:59:59.000Z

    93 Figure I-1: Electricty Use for a Specific Feeder in Santerritory. Figure I-1: Electricty Use for a Specific Feeder

  12. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    Flow Chart of Sample Selection Process Appoint manufactures to choose the samples (4 sets) Sample energy

  13. Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement

    E-Print Network [OSTI]

    Bode, Josh

    2013-01-01T23:59:59.000Z

    017F.PDF KEMA, Inc. 2011. PJM Empirical Analysis of DemandMethods. Prepared for the PJM Markets Implementation~/media/markets-ops/dsr/pjm-analysis-of-dr-baseline-methods-

  14. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01T23:59:59.000Z

    Renewable Energy Laboratory, Facility of the U.S. Department of Energy ODP Ozone depletion potential

  15. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    China Energy Efficiency Label System (CEELS) In order to improve the energy efficiency of main energy consuming products, the gov-

  16. Five ENERGY STAR Room Air Conditioners Fail Testing | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport inEnergy June 6-7, 2013 MeetingEA #FebruaryFisker, Tesla, and American

  17. DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613PortsmouthBartlesvilleAbout »Department of2 DOE FitsEnergyMessagein

  18. DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613PortsmouthBartlesvilleAbout »Department of2Violating Minimum Appliance Standards |

  19. Tips for Running an Air Conditioner Without Breaking the Bank | Department

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov. Are you sure you wantJoin us for|Idahothe New Funding Constructs forofDOETips Forof

  20. 2015-02-12 Issuance: Test Procedures for Portable Air Conditioners; Notice

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy China 2015ofDepartment ofCBFO-13-3322(EE)DepartmentVery5 AnnualDillingham,7,58of Proposed

  1. Advanced Thin Film Thermoelectric Systems forEfficient Air-Conditioners |

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy China 2015ofDepartmentDepartment of2Partners in the Spotlight Novelis2AdvancedofDepartment

  2. DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"WaveInteractions and Policy (2009) | Department

  3. DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"WaveInteractions and PolicyCybersecurity ThreatsViolating Minimum

  4. DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: Theof"WaveInteractions and PolicyCybersecurity ThreatsViolating

  5. Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMay 2015 <Department ofDepartment| Department of Energy Money and Stay

  6. YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your DensityEnergy U.S.-China Electric VehicleCenters |-- 9:00 AM OpeningWorld's LargestYou |Y-12I

  7. Tips for Running an Air Conditioner Without Breaking the Bank | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMayDepartmentTest for PumpingThe| Department of EnergyPhaseCostsTipTipsof

  8. Cash for Coolers

    E-Print Network [OSTI]

    Davis, Lucas W.; Fuchs, Alan; Gertler, Paul J.

    2012-01-01T23:59:59.000Z

    for refrigerator and air conditioner replacement and allof refrigerator and air-conditioner replacement on householdthat replacement of residential air conditioners would save

  9. Impact of Large Scale Energy Efficiency Programs On Consumer Tariffs and Utility Finances in India

    E-Print Network [OSTI]

    Abhyankar, Nikit

    2011-01-01T23:59:59.000Z

    like refrigerator and air conditioner replacements. Thisiv) Replacement of conventional air conditioners by energy-ii) Replacement of conventional air conditioners by energy-

  10. Cash for Coolers

    E-Print Network [OSTI]

    Davis, Lucas W.; Fuchs, Alan; Gertler, Paul J.

    2012-01-01T23:59:59.000Z

    of refrigerator and air-conditioner replacement on householdfor refrigerator and air conditioner replacement and allassociated with air-conditioner replacement were to be

  11. Impact of Large Scale Energy Efficiency Programs On Consumer Tariffs and Utility Finances in India

    E-Print Network [OSTI]

    Abhyankar, Nikit

    2011-01-01T23:59:59.000Z

    like refrigerator and air conditioner replacements. This5-star air conditioners are the efficient replacement, withiv) Replacement of conventional air conditioners by energy-

  12. Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms

    E-Print Network [OSTI]

    Apte, Michael; Michael G. Apte, Bourassa Norman, David Faulkner, Alfred T. Hodgson,; Toshfumi Hotchi, Michael Spears, Douglas P. Sullivan, and Duo Wang

    2008-01-01T23:59:59.000Z

    a prototype improved heat pump air conditioner was developedwith standard 10 SEER heat pump air conditioner equipment.generated by the wall mount heat pump air conditioner (HPAC)

  13. Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in China

    E-Print Network [OSTI]

    McNeil, Michael A.

    2012-01-01T23:59:59.000Z

    television and an air conditioner. In the future, ownershipresidential room air conditioners require the largesttelevision and an air conditioner. In the future, ownership

  14. FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH

    E-Print Network [OSTI]

    Lesieutre, Bernard

    2013-01-01T23:59:59.000Z

    9   1.2.1.   Air Conditioner Testing and 16   2.0   Air Conditioner Results of Residential Air Conditioner Testing in WECC,” 

  15. Current Status and Future Scenarios of Residential Building Energy Consumption in China

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    in MJ /household-year. Air conditioner and refrigerator endand 217.4% for air conditioner in Japan in 2000 (IEEJ,appliances including air conditioner, refrigerator, clothes

  16. Modeling diffusion of electrical appliances in the residential sector

    E-Print Network [OSTI]

    McNeil, Michael A.

    2010-01-01T23:59:59.000Z

    Error Distribution - Air Conditioners Error Distribution -televisions, and air conditioners 5 . The task of modelingfrom UNDESA. 2.1.3. Air Conditioner Climate Variable

  17. RESIDENTIAL THERMOSTATS: COMFORT CONTROLS IN CALIFORNIA HOMES

    E-Print Network [OSTI]

    Meier, Alan K.

    2008-01-01T23:59:59.000Z

    Measures on Residential Air Conditioner Loads. Proc. ACEEEDeterminants of Central Air Conditioner Duty Cycles. Proc.at the number of air conditioners that might actually

  18. TWOZONE USERS MANUAL. 2d ed

    E-Print Network [OSTI]

    Gadgil, A.J.

    2008-01-01T23:59:59.000Z

    cooler, improved air conditioner algorithm, ability to readcooling the house with air-conditioner, evaporative-cooler= starting month of air-conditioner (AC) operation. = ending

  19. Customer Impact Evaluation for the 2009 Southern California Edison Participating Load Pilot

    E-Print Network [OSTI]

    Gifford, William

    2010-01-01T23:59:59.000Z

    duration interruptions of air-conditioners. Still, we should14 3.2.2 Typical Summer Air Conditioner15 Table 3.3 Air Conditioner

  20. Check-Testing of Manufacturer Self Reported Labeling Data & Compliance with MEPS

    E-Print Network [OSTI]

    Zhou, Nan

    2008-01-01T23:59:59.000Z

    2 Room Air-conditioner Air-conditioner Initial test- ing Re-HFS BJS BJS HFS BJS BJS Non- compliant* Air-conditioner9 Table 5. Room Air Conditioner 2000

  1. Tariff-based analysis of commercial building electricity prices

    E-Print Network [OSTI]

    Coughlin, Katie M.; Bolduc, Chris A.; Rosenquist, Greg J.; Van Buskirk, Robert D.; McMahon, James E.

    2008-01-01T23:59:59.000Z

    Central Air Conditioners and Heat Pump Energy ConservationUnitary Air Conditioners and Heat Pumps ANOPR Technical

  2. Current Status and Future Scenarios of Residential Building Energy Consumption in China

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    stove district heating heat pump air conditioner Table 2Heat Pump Percentage (%) Heat Pump Air Conditioner District

  3. Method and apparatus for analog signal conditioner for high speed, digital x-ray spectrometer

    DOE Patents [OSTI]

    Warburton, William K. (1300 Mills St., Menlo Park, CA 94025); Hubbard, Bradley (Santa Cruz, CA)

    1999-01-01T23:59:59.000Z

    A signal processing system which accepts input from an x-ray detector-preamplifier and produces a signal of reduced dynamic range for subsequent analog-to-digital conversion. The system conditions the input signal to reduce the number of bits required in the analog-to-digital converter by removing that part of the input signal which varies only slowly in time and retaining the amplitude of the pulses which carry information about the x-rays absorbed by the detector. The parameters controlling the signal conditioner's operation can be readily supplied in digital form, allowing it to be integrated into a feedback loop as part of a larger digital x-ray spectroscopy system.

  4. Desiccant Enhanced Evaporative Air-Conditioning (DEVap): Evaluation of a New Concept in Ultra Efficient Air Conditioning

    SciTech Connect (OSTI)

    Kozubal, E.; Woods, J.; Burch, J.; Boranian, A.; Merrigan, T.

    2011-01-01T23:59:59.000Z

    NREL has developed the novel concept of a desiccant enhanced evaporative air conditioner (DEVap) with the objective of combining the benefits of liquid desiccant and evaporative cooling technologies into an innovative 'cooling core.' Liquid desiccant technologies have extraordinary dehumidification potential, but require an efficient cooling sink. DEVap's thermodynamic potential overcomes many shortcomings of standard refrigeration-based direct expansion cooling. DEVap decouples cooling and dehumidification performance, which results in independent temperature and humidity control. The energy input is largely switched away from electricity to low-grade thermal energy that can be sourced from fuels such as natural gas, waste heat, solar, or biofuels.

  5. Future Air Conditioning Energy Consumption in Developing Countriesand what can be done about it: The Potential of Efficiency in theResidential Sector

    SciTech Connect (OSTI)

    McNeil, Michael A.; Letschert, Virginie E.

    2007-05-01T23:59:59.000Z

    The dynamics of air conditioning are of particular interestto energy analysts, both because of the high energy consumption of thisproduct, but also its disproportionate impact on peak load. This paperaddresses the special role of this end use as a driver of residentialelectricity consumption in rapidly developing economies. Recent historyhas shown that air conditioner ownership can grow grows more rapidly thaneconomic growth in warm-climate countries. In 1990, less than a percentof urban Chinese households owned an air conditioner; by 2003 this numberrose to 62 percent. The evidence suggests a similar explosion of airconditioner use in many other countries is not far behind. Room airconditioner purchases in India are currently growing at 20 percent peryear, with about half of these purchases attributed to the residentialsector. This paper draws on two distinct methodological elements toassess future residential air conditioner 'business as usual' electricityconsumption by country/region and to consider specific alternative 'highefficiency' scenarios. The first component is an econometric ownershipand use model based on household income, climate and demographicparameters. The second combines ownership forecasts and stock accountingwith geographically specific efficiency scenarios within a uniqueanalysis framework (BUENAS) developed by LBNL. The efficiency scenariomodule considers current efficiency baselines, available technologies,and achievable timelines for development of market transformationprograms, such as minimum efficiency performance standards (MEPS) andlabeling programs. The result is a detailed set of consumption andemissions scenarios for residential air conditioning.

  6. Central Air Conditioners","Heat Pumps","Individual Air Conditioners","District Chilled Water","Central Chillers","Packaged

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghurajiConventionalMississippi"site. If you need43 3.84LeaseProcess: Catalytic Reforming Catalytic4.

  7. Central Air Conditioners","Heat Pumps","Individual Air Conditioners","District Chilled Water","Central Chillers","Packaged

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghurajiConventionalMississippi"site. If you need43 3.84LeaseProcess: Catalytic Reforming Catalytic4.5.

  8. Avoiding 100 new power plants by increasing efficiency of room air conditioners in India: opportunities and challenges

    SciTech Connect (OSTI)

    Phadke, Amol; Abhyankar, Nikit; Shah, Nihar; [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

    2013-10-15T23:59:59.000Z

    Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40% cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

  9. Effects of system cycling, evaporator airflow, and condenser coil fouling on the performance of residential split-system air conditioners

    E-Print Network [OSTI]

    Dooley, Jeffrey Brandon

    2005-02-17T23:59:59.000Z

    ????????????????????.. 63 Energy Efficiency Ratio (EER)???????????.. 65 Sensible Heat Factor (SHF)????????????? 66 Power Consumption???????????????... 67 Condenser Discharge Pressure and Temperature????... 69 Evaporator Suction Pressure...??????????. 76 Capacity????????????????????.. 78 Energy Efficiency Ratio (EER)???????????.. 81 Sensible Heat Factor (SHF)????????????.... 83 Power Consumption???????????????... 85 Condenser Discharge Pressure???????????... 86...

  10. PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976

    E-Print Network [OSTI]

    Dao, K.

    2010-01-01T23:59:59.000Z

    Road Springfield, Virginia 22161 Price: Printed Copy $5.50; Microfiche $2.25 LBL-5911 PERFORMANCE OF AN EXPERIMENTAL SOLAR-

  11. Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges

    SciTech Connect (OSTI)

    Phadke, Amol; Abhyankar, Nikit; Shah, Nihar

    2014-06-19T23:59:59.000Z

    Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40percent cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

  12. PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976

    E-Print Network [OSTI]

    Dao, K.

    2010-01-01T23:59:59.000Z

    to extrapolated data from Linde (pool boiling of 50 % NH 3 -ft area: 4 ft 0.584 inch rD, Linde hi-flux tubing Analyzer (ring packing 16" diameter Linde hi-flux tubing XBL 757-3558

  13. Simulation of Dehumidification Characteristics of High Efficiency Residential Central Air-Conditioners in Hot and Humid Climates

    E-Print Network [OSTI]

    Katipamula, S.; O'Neal, D.; Somasundram, S.

    1988-01-01T23:59:59.000Z

    ) thermostat set point and dead band, and (ill) sizing of unit relative to the design load of the residence. The units are evaluated on their ability to maintain conditions in the ASHRAE comfort zone in a typical residence in Houston area. The units...

  14. NREL Demonstrates Game-Changing Air Conditioner Technology (Fact Sheet), Highlights in Research & Development, NREL (National Renewable Energy Laboratory)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit | National Nuclear SecurityJune

  15. NREL Solves Residential Window Air Conditioner Performance Limitations (Fact Sheet), Highlights in Research & Development, NREL (National Renewable Energy Laboratory)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit | National Nuclear13 Denver West Parkway Golden, CO

  16. PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976

    E-Print Network [OSTI]

    Dao, K.

    2010-01-01T23:59:59.000Z

    rates were calibrated The heat inputs to the generator (qG)of chilled water, lbs/hr heat input from hot water, Btu/hrof Run 20e. Q cw P T heat input from chilled water, Btu/hr

  17. An Evaluation of the Effects of Refrigerant Charge on a Residential Central Air Conditioner with Orifice Expansion

    E-Print Network [OSTI]

    O'Neal, D. L.; Ramsey, C. J.; Farzad, M.

    1989-01-01T23:59:59.000Z

    had one row of tubes with spine fins spaced at 20 per inch. The face area of the coil was 20.94 ft with refrigerant tube sizes of 3/8". The outdoor fan was located on the top of the outdoor coil. The fan specifications are given in Table 2.... 2.5 Table 2.1 - Fan Specification Refrigerant Side A schematic of the refrigerant circuit is shown in Figure 2.3. Refrigerant pressures were monitored at the 6 points shown with the use of 0-300 psig pressure transducers. To accurately measure...

  18. PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976

    E-Print Network [OSTI]

    Dao, K.

    2010-01-01T23:59:59.000Z

    U. THW . In T HW out TSS Q UW (Btu/hr) LiT m U IllWS (Ibs/OF) (OF) (OF) (OF) (OF) (Btu/hr ft2.F 20A 20C 19A lIS 17BU Run number m HW (1bs/hr) (Btu/hr- ft2_F) mS == ! z(nlWS+

  19. Understanding Energy Impacts of Oversized Air Conditioners (Fact Sheet), NREL Highlights, Research & Development, NREL (National Renewable Energy Laboratory)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of ScienceandMesa del SolStrengthening aTurbulence mayUndergraduate ProgramCenter |

  20. A fundamentally new approach to air-cooled heat exchangers.

    SciTech Connect (OSTI)

    Koplow, Jeffrey P.

    2010-01-01T23:59:59.000Z

    We describe breakthrough results obtained in a feasibility study of a fundamentally new architecture for air-cooled heat exchangers. A longstanding but largely unrealized opportunity in energy efficiency concerns the performance of air-cooled heat exchangers used in air conditioners, heat pumps, and refrigeration equipment. In the case of residential air conditioners, for example, the typical performance of the air cooled heat exchangers used for condensers and evaporators is at best marginal from the standpoint the of achieving maximum the possible coefficient of performance (COP). If by some means it were possible to reduce the thermal resistance of these heat exchangers to a negligible level, a typical energy savings of order 30% could be immediately realized. It has long been known that a several-fold increase in heat exchanger size, in conjunction with the use of much higher volumetric flow rates, provides a straight-forward path to this goal but is not practical from the standpoint of real world applications. The tension in the market place between the need for energy efficiency and logistical considerations such as equipment size, cost and operating noise has resulted in a compromise that is far from ideal. This is the reason that a typical residential air conditioner exhibits significant sensitivity to reductions in fan speed and/or fouling of the heat exchanger surface. The prevailing wisdom is that little can be done to improve this situation; the 'fan-plus-finned-heat-sink' heat exchanger architecture used throughout the energy sector represents an extremely mature technology for which there is little opportunity for further optimization. But the fact remains that conventional fan-plus-finned-heat-sink technology simply doesn't work that well. Their primary physical limitation to performance (i.e. low thermal resistance) is the boundary layer of motionless air that adheres to and envelops all surfaces of the heat exchanger. Within this boundary layer region, diffusive transport is the dominant mechanism for heat transfer. The resulting thermal bottleneck largely determines the thermal resistance of the heat exchanger. No one has yet devised a practical solution to the boundary layer problem. Another longstanding problem is inevitable fouling of the heat exchanger surface over time by particulate matter and other airborne contaminants. This problem is especially important in residential air conditioner systems where often little or no preventative maintenance is practiced. The heat sink fouling problem also remains unsolved. The third major problem (alluded to earlier) concerns inadequate airflow to heat exchanger resulting from restrictions on fan noise. The air-cooled heat exchanger described here solves all of the above three problems simultaneously. The 'Air Bearing Heat Exchanger' provides a several-fold reduction in boundary layer thickness, intrinsic immunity to heat sink fouling, and drastic reductions in noise. It is also very practical from the standpoint of cost, complexity, ruggedness, etc. Successful development of this technology is also expected to have far reaching impact in the IT sector from the standpointpoint of solving the 'Thermal Brick Wall' problem (which currently limits CPU clocks speeds to {approx}3 GHz), and increasing concern about the the electrical power consumption of our nation's information technology infrastructure.

  1. Magnetic Refrigeration Technology for High Efficiency Air Conditioning

    SciTech Connect (OSTI)

    Boeder, A; Zimm, C

    2006-09-30T23:59:59.000Z

    Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate heat exchangers or oil distribution issues found in traditional vapor compression systems.

  2. Calendar Year 2007 Program Benefits for U.S. EPA Energy Star Labeled Products: Expanded Methodology

    E-Print Network [OSTI]

    Sanchez, Marla

    2010-01-01T23:59:59.000Z

    Air Conditioners and Air Source Heat Pumps. Unpublishedpackage central air conditioners and heat pumps, rated atManufacturers air source heat pump American Society of

  3. Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1

    E-Print Network [OSTI]

    Johnson, F.X.

    2010-01-01T23:59:59.000Z

    A H A M . 1991. Room Air Conditioner Data. Association of7. FUTURE WORK 7.1 Room Air Conditioners 7.2. Common heatingShipments of Unitary Air Conditioners and Heat Pumps. Air-

  4. Energy Consumption, Efficiency, Conservation, and Greenhouse Gas Mitigation in Japan's Building Sector

    E-Print Network [OSTI]

    2006-01-01T23:59:59.000Z

    4.4.3 C o o l i n g Air Conditioner Multi-room Load AirGHPs) Chillers Air Conditioner COP Desiccant Conditioningappliances such as air-conditioners, refrigerators and

  5. Calendar Year 2009 Program Benefits for ENERGY STAR Labeled Products

    E-Print Network [OSTI]

    Homan, Gregory K

    2011-01-01T23:59:59.000Z

    covers central air conditioners and heat pumps with up toconditioning, ASHP = air source heat pump, HP = heat pump,Conditioners and Air-Source Heat Pumps • Commercial Fryers •

  6. Calendar Year 2008 Program Benefits for ENERGY STAR Labeled Products

    E-Print Network [OSTI]

    Homan, GregoryK

    2010-01-01T23:59:59.000Z

    covers central air conditioners and heat pumps with up toconditioning, ASHP = air source heat pump, HP = heat pump,Conditioners and Air-Source Heat Pumps • Commercial Fryers •

  7. Residence Hall & Furnished

    E-Print Network [OSTI]

    Polly, David

    Air Conditioner Units . . . . . . . . . . . . . . . . . 7 Bunking/Lofting Beds & Air Conditioning . . . . . . . . . . . . 9 Mailing Address

  8. TABLE OFCONTENTS Contract Information

    E-Print Network [OSTI]

    Polly, David

    ....................................... 3 Your Room Assignments .......................................................... 4 Air Conditioner ................................................... 4 Consolidation ......................................................... 4 Heating &Air

  9. Market and behavioral barriers to energy efficiency: A preliminary evaluation of the case for tariff financing in California

    E-Print Network [OSTI]

    Fujita, K. Sydny

    2012-01-01T23:59:59.000Z

    for central air conditioner replacements Efficiency level 20state, replacement of outdated central air conditioners orAir Conditioners .. 15   Furnaces 16   Water heaters .. 17   Potential savings from rental housing unit water heater replacements .

  10. CONTROL SYSTEM FOR SOLAR HEATING and COOLING

    E-Print Network [OSTI]

    Dols, C.

    2010-01-01T23:59:59.000Z

    ~O"')4 REFERENCES The air conditioner work is the subject ofAmmonia-Water Absorption Air Conditioner", by M. Simmons, R.water absorption air conditioner, (1) and the establishment

  11. BPM Motors in Residential Gas Furnaces: What are the Savings?

    E-Print Network [OSTI]

    Lutz, James; Franco, Victor; Lekov, Alex; Wong-Parodi, Gabrielle

    2006-01-01T23:59:59.000Z

    Comfort Series 13 Air Conditioner with Puron Refrigerant.for new houses with 3.5 ton air-conditioners from a study ofblower use by the air conditioner and stand-by power.

  12. TWOZONE USERS MANUAL

    E-Print Network [OSTI]

    Gadgil, Ashok J.

    2010-01-01T23:59:59.000Z

    9. Sizing chart for air conditioner. z ~::~~OOOOOOOOOOOOOOOOoperation of either an air conditioner and/or an evaporativecooler, improved air-conditioner algorithm, ability to read

  13. TWOZONE USERS MANUAL

    E-Print Network [OSTI]

    Gadgil, Ashok J.

    2008-01-01T23:59:59.000Z

    9. Sizing chart for air conditioner. z ~::~~OOOOOOOOOOOOOOOOoperation of either an air conditioner and/or an evaporativecooler, improved air-conditioner algorithm, ability to read

  14. Global Potential of Energy Efficiency Standards and Labeling Programs

    E-Print Network [OSTI]

    McNeil, Michael A

    2008-01-01T23:59:59.000Z

    impact of room air conditioners energy labels in Malaysia."of electric Room Air Conditioner." Energy Economics 20Standard Levels for Room Air Conditioners. McNeil, M. A. ,

  15. DOE Institutes Enforcement Action Against AeroSys, Inc. for Failure...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard...

  16. PowerPoint Presentation

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    1990, 1993, 2001, 2014 NAECA 1987 Room Air Conditioners 1990, 2000, 2014 NAECA 1987 Central Air Conditioners and Heat Pumps 19921993, 2006, 2015 NAECA 1987 Water Heaters...

  17. Impacts of Imported Liquefied Natural Gas on Residential Appliance Components: Literature Review

    E-Print Network [OSTI]

    Lekov, Alex

    2010-01-01T23:59:59.000Z

    on New FVIR Water Heaters." Retrieved 04/17/2009, 2009, fromAir Conditioners, Water Heaters, Direct Heating Equipment,Air Conditioners, Water Heaters, Direct Heating Equipment,

  18. Using National Survey Data to Estimate Lifetimes of Residential Appliances

    E-Print Network [OSTI]

    Lutz, James D.

    2013-01-01T23:59:59.000Z

    furnaces, boilers, water heaters, room air-conditioners,furnaces, boilers, water heaters, room air-conditioners (and Electric Storage Water Heaters Table 6 and 7 show the

  19. Laboratory Performance Testing of Residential Window Mounted...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Key Issues High-Efficiency Window Air Conditioners - Building America Top Innovation 2014-05-05 Issuance: Test Procedure for Portable Air Conditioners; Notice of Data Availability...

  20. FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH

    E-Print Network [OSTI]

    Lesieutre, Bernard

    2013-01-01T23:59:59.000Z

    Air Conditioner Testing in WECC,” IEEE Power  Engineering Air Conditioner Modeling, WECC Load Modeling Task  Force in power system studies: WECC progress update,? Power and 

  1. Page 1 of 3 Radiogram No. 1679u Form 24 for 03/02/2013

    E-Print Network [OSTI]

    Subsystem Preventive Maintenance, Group E FGB 2 Fan Cleaning Inspection of Air Conditioner Inspection Inspection of Air Conditioner Inspection and Cleaning of Auxiliary Computer System () Laptops

  2. Arnold Schwarzenegger Preserving California's

    E-Print Network [OSTI]

    ....................................................112 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods..........51 B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps.......81 B-3 Standards for Packaged Terminal Air Conditioners and Packaged Terminal Heat

  3. Table Contents Page i 2013 Nonresidential Compliance Manual January 2014

    E-Print Network [OSTI]

    Table B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner ....................................................................................11 Table B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps...........12 Table B-3 Standards for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps

  4. Cascade Reverse Osmosis Air Conditioning System: Cascade Reverse Osmosis and the Absorption Osmosis Cycle

    SciTech Connect (OSTI)

    None

    2010-09-01T23:59:59.000Z

    BEETIT Project: Battelle is developing a new air conditioning system that uses a cascade reverse osmosis (RO)-based absorption cycle. Analyses show that this new cycle can be as much as 60% more efficient than vapor compression, which is used in 90% of air conditioners. Traditional vapor-compression systems use polluting liquids for a cooling effect. Absorption cycles use benign refrigerants such as water, which is absorbed in a salt solution and pumped as liquid—replacing compression of vapor. The refrigerant is subsequently separated from absorbing salt using heat for re-use in the cooling cycle. Battelle is replacing thermal separation of refrigerant with a more efficient reverse osmosis process. Research has shown that the cycle is possible, but further investment will be needed to reduce the number of cascade reverse osmosis stages and therefore cost.

  5. Synchronous Programs Testing Language Mouna TKA Mnad1

    E-Print Network [OSTI]

    Boyer, Edmond

    of the language Let's consider the following simple reactive program, an air-conditioner controller. The program inputs are: onOff (Boolean: true when the user pushes the On-Off button of the air-conditioner), Tamb of the air-conditioner ) and Tout (integer: indicates the temperature of the air that the air-conditioner

  6. Air Quality: Construction Project Air Permit Requirements

    E-Print Network [OSTI]

    Wechsler, Risa H.

    Air Quality: Construction Project Air Permit Requirements Department: Chemical and General Safety Program: Air Quality Owner: Program Manager Authority: ES&H Manual, Chapter 30, Air Quality1 All manager or operator must submit the completed form to the air quality program manager before the project

  7. Air Pollution (Illinois)

    Broader source: Energy.gov [DOE]

    This article states regulations for monitoring air pollution, methods for permit applications, emission limitations for pollutants and air quality standards.

  8. Essays on the household-level effects of house price growth

    E-Print Network [OSTI]

    Sitgraves, Claudia Ayanna

    2009-01-01T23:59:59.000Z

    replacement of major equipment items such as water heaters, furnaces, and central air conditioners” (

  9. California DREAMing: the design of residential demand responsive technology with people in mind

    E-Print Network [OSTI]

    Peffer, Therese E.

    2009-01-01T23:59:59.000Z

    replacement (Vandervort, 2006). The proper changing of the refrigerant can also significantly improve air conditioner

  10. Essays on the household-level effects of house price growth

    E-Print Network [OSTI]

    Sitgraves, Claudia Ayanna

    2009-01-01T23:59:59.000Z

    and replacement of major equipment items such as water heaters, furnaces, and central air conditioners” (

  11. A Generalized Battery Model of a Collection of Thermostatically Controlled Loads for Providing Ancillary Service

    E-Print Network [OSTI]

    Sanandaji, Borhan M.

    . Residential Thermostatically Controlled Loads (TCLs) such as air conditioner, heat pump, water heater, and re

  12. Realized and Projected Impacts of U.S. Energy Efficiency Standards for Residential and Commercial Appliances

    E-Print Network [OSTI]

    Meyers, Stephen P.

    2008-01-01T23:59:59.000Z

    and Heat Pumps Room Air Conditioners Water Heaters Gas Furnaces Clothes Washers Clothes Dryers Dishwashers COMMERCIAL

  13. Investigation of efficiency droop for InGaN-based UV light-emitting diodes with InAlGaN barrier

    E-Print Network [OSTI]

    applications in photocatalytic deodorizing such as air conditioner,1 and there have been interests in solid

  14. IMPACT OF FOREST CERTIFICATION: FROM THE PERSPECTIVE OF FOREST CONCESSIONAIRES' STAFFS

    E-Print Network [OSTI]

    by acting as anti pollutants, natural air conditioner and balancing the ecosystem. However, deforestation

  15. ARRA Proposed Award: The Affordable Multifamily Retrofit Initiative (the Initiative)

    E-Print Network [OSTI]

    Star appliance replacement; air conditioner and/or furnace replacement or installation defect repair; cool roofs

  16. Applied Intelligence 13, 259264, 2000 c 2000 Kluwer Academic Publishers. Manufactured in The Netherlands.

    E-Print Network [OSTI]

    Covington, Michael A.

    Problem Consider the following rules for controlling an air conditioner: (1) Run the air conditioner when the temperature is over 78 . (2) Do not run the air conditioner when the AC line voltage is low, unless) Never run the air conditioner if it was turned off less than 4 minutes ago (to protect the compressor

  17. ARRA Proposed Award: Home Performance Program

    E-Print Network [OSTI]

    Star appliance replacement; air conditioner and/or furnace replacement or installation defect repair; cool roofs

  18. Volume 9 Number 3 Fall 2000 University to invest

    E-Print Network [OSTI]

    manager of Purdue's mechanical and electrical structures, had all the window air conditioner units removed

  19. SpecialBulletin page 1California Energ y Commission March 2006 no. 84

    E-Print Network [OSTI]

    that the federal air conditioner standards that require a minimum SEER 13 went into effect on January 23, 2006. Can an air conditioner that has a SEER rating less than SEER 13 be installed in newly constructed buildings of manufacture of the air conditioner. To comply with the federal appliance standards, any air conditioner

  20. TENANT NAME ADDRESS APT#

    E-Print Network [OSTI]

    Kravets, Robin

    cabinets Bath exhaust fan Medicine cabinet Air conditioner Washer/dryer Other # KEYS: RECEIVED RETURNED

  1. Additions, Alterations, and Repairs Introduction Page 8-1 8 Additions, Alterations, and Repairs

    E-Print Network [OSTI]

    conditioning and heating system. 5. Replacing an air conditioner or the exterior unit or indoor coil of a split system air conditioner. 6. Replacing of a furnace or water heater. 7. Replacing windows where all compressor in an air conditioner but not replacing the entire air conditioner. 3. Replacing a failed fan

  2. 2013 California Building Energy Efficiency Standards December 2011 CODES AND STANDARDS ENHANCEMENT INITIATIVE (CASE)

    E-Print Network [OSTI]

    ...................................................................................23 4.3.4 The Effect of Non-condensables on Air Conditioner Efficiency

  3. Potential Impact of Adopting Maximum Technologies as Minimum Efficiency Performance Standards in the U.S. Residential Sector

    E-Print Network [OSTI]

    Letschert, Virginie

    2010-01-01T23:59:59.000Z

    air conditioners, water heaters and furnaces) are modeledair conditioners, water heaters and furnaces) UnregulatedBAT option for electric water heater and condensing water

  4. U< I 7 jjORNLCON-3S) EXPERIMENTAL ANALYSIS OF A WINDOW

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    UAIR CONDITIONER OAK RIDGE WITH NATIONAL R-22. #12;ORNUCON-389 EXPERIMENTAL ANALYSIS OF A WINDOW AIR CONDITIONER WITH R-22 AND ZEOTROPIC MIXTURE OF R

  5. Metal-Air Batteries

    SciTech Connect (OSTI)

    Zhang, Jiguang; Bruce, Peter G.; Zhang, Gregory

    2011-08-01T23:59:59.000Z

    Metal-air batteries have much higher specific energies than most currently available primary and rechargeable batteries. Recent advances in electrode materials and electrolytes, as well as new designs on metal-air batteries, have attracted intensive effort in recent years, especially in the development of lithium-air batteries. The general principle in metal-air batteries will be reviewed in this chapter. The materials, preparation methods, and performances of metal-air batteries will be discussed. Two main metal-air batteries, Zn-air and Li-air batteries will be discussed in detail. Other type of metal-air batteries will also be described.

  6. Air temperature thresholds for indoor comfort and perceived air quality

    E-Print Network [OSTI]

    Zhang, Hui; Edward, Arens; Pasut, Wilmer

    2012-01-01T23:59:59.000Z

    system on perceived air quality, Indoor Air 2008, August 17-perception of indoor air quality during immediate and longeraddressing indoor air quality, thermal environment, lighting

  7. Air temperature thresholds for indoor comfort and perceived air quality

    E-Print Network [OSTI]

    Zhang, Hui; Edward, Arens; Pasut, Wilmer

    2012-01-01T23:59:59.000Z

    in the Netherlands, Indoor Air 2, 127 – 136. BuildingPaliaga, G. (2009) Moving air for comfort. ASHRAE Journal,ventilation system on perceived air quality, Indoor Air

  8. Feasibility of air capture

    E-Print Network [OSTI]

    Ranjan, Manya

    2010-01-01T23:59:59.000Z

    Capturing CO2 from air, referred to as Air Capture, is being proposed as a viable climate change mitigation technology. The two major benefits of air capture, reported in literature, are that it allows us to reduce the ...

  9. Moving air for comfort

    E-Print Network [OSTI]

    Arens, Edward; Turner, Stephen; Zhang, Hui; Paliaga, Gwelen

    2009-01-01T23:59:59.000Z

    Brager, L. Zagreus. 2007, “Air movement preferences observed709-731. 9. Toftum, J. 2004. “Air movement – good or bad? ”Indoor Air 14, pp 40-45. 10. Gong, N. , K. Tham, A. Melikov,

  10. Air Pollution Control (Oklahoma)

    Broader source: Energy.gov [DOE]

    This chapter enumerates primary and secondary ambient air quality standards and the significant deterioration increments. Significant deterioration refers to an increase in ambient air pollution...

  11. Primary zone air proportioner

    DOE Patents [OSTI]

    Cleary, Edward N. G. (San Diego, CA)

    1982-10-12T23:59:59.000Z

    An air proportioner is provided for a liquid hydrocarbon fueled gas turbine of the type which is convertible to oil gas fuel and to coal gas fuel. The turbine includes a shell for enclosing the turbine, an air duct for venting air in said shell to a gasifier, and a fuel injector for injecting gasified fuel into the turbine. The air proportioner comprises a second air duct for venting air from the air duct for mixing with fuel from the gasifier. The air can be directly injected into the gas combustion basket along with the fuel from the injector or premixed with fuel from the gasifier prior to injection by the fuel injector.

  12. AiR surface: AiR surface 1

    E-Print Network [OSTI]

    Tanaka, Jiro

    AiR surface: 1 PDA AiR surface 1 1: AiR surface () () 2 [1] [2] 3 AiR surface AiR surface surface surface surface 3.1 surface [3]( 3 ) surface 3.2 surface surface AiR surface 4 AiR surface surface AiR surface: Virtual Touch Panel

  13. Building Energy-Efficiency Best Practice Policies and Policy Packages

    E-Print Network [OSTI]

    Levine, Mark

    2014-01-01T23:59:59.000Z

    air sealing cracks; and installing programmable thermostats, energy-efficient replacement water heaters, heat pumps, air conditioners,

  14. DSM Electricity Savings Potential in the Buildings Sector in APP Countries

    E-Print Network [OSTI]

    McNeil, MIchael

    2011-01-01T23:59:59.000Z

    Packaged terminal air conditioners and heat pumps Warm-airheat pump efficiency is assumed to be equal to air

  15. 7Name ________________________________ System Watts Energy source

    E-Print Network [OSTI]

    , which will do work to move air in your air conditioner, or to keep food cold in your refrigerator. When

  16. Air Pollution Spring 2010

    E-Print Network [OSTI]

    ATS 555 Air Pollution Spring 2010 T Th 11:00 ­ 12:15, NESB 101 Instructor: Prof. Sonia Kreidenweis an understanding of types and sources of air pollution. 2. Examine concentrations of air pollutants and their effects on health and welfare. Review regulations governing air pollution. 3. Examine the meteorological

  17. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 2, Fluorescent lamp ballasts, television sets, room air conditioners, and kitchen ranges and ovens

    SciTech Connect (OSTI)

    Not Available

    1993-11-01T23:59:59.000Z

    This document is divided into ``volumes`` B through E, dealing with individual classes of consumer products. Chapters in each present engineering analysis, base case forecasts, projected national impacts of standards, life-cycle costs and payback periods, impacts on manufacturers, impacts of standards on electric utilities, and environmental effects. Supporting appendices are included.

  18. 2005 Status Report Savings Estimates for the ENERGY STAR(R) Voluntary Labeling Program

    E-Print Network [OSTI]

    Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla

    2006-01-01T23:59:59.000Z

    and Cooling - Furnace (Gas or Oil) - Central Air Conditioner - Air-Source Heat Pump - Geothermaland Cooling - Furnaces (Gas or Oil) - Central Air Conditioners - Air-Source Heat Pumps - Geothermaland Cooling - Furnaces (Gas or Oil) - Central Air Conditioners - Air-Source Heat Pumps - Geothermal

  19. Development of Refrigerant Change Indicator and Dirty Air Filter Sensor

    SciTech Connect (OSTI)

    Mei, V.

    2003-06-24T23:59:59.000Z

    The most common problems affecting residential and light commercial heating, ventilation, and air-conditioning (HVAC) systems are slow refrigerant leaks and dirty air filters. Equipment users are usually not aware of a problem until most of the refrigerant has escaped or the air filter is clogged with dirt. While a dirty air filter can be detected with a technology based on the air pressure differential across the filter, such as a ''whistling'' indicator, it is not easy to incorporate this technology into existing HVAC diagnostic equipment. Oak Ridge National Laboratory is developing a low-cost, nonintrusive refrigerant charge indicator and dirty air filter detection sensor. The sensors, based on temperature measurements, will be inexpensive and easy to incorporate into existing heat pumps and air conditioners. The refrigerant charge indicator is based on the fact that when refrigerant starts to leak, the evaporator coil temperature starts to drop and the level of liquid subcooling drops. When the coil temperature or liquid subcooling drops below a preset reading, a signal, such as a yellow warning light, can be activated to warn the equipment user that the system is undercharged. A further drop of coil temperature or liquid subcooling below another preset reading would trigger a second warning signal, such as a red warning light, to warn the equipment user that the unit now detects a leak and immediate action should be taken. The warning light cannot be turned off until it is re-set by a refrigeration repairman. To detect clogged air filters, two additional temperature sensors can be applied, one each across the evaporator. When the air filter is accumulating buildup, the temperature differential across the evaporator will increase because of the reduced airflow. When the temperature differential reaches a pre-set reading, a signal will be sent to the equipment user that the air filter needs to be changed. A traditional refrigerant charge indicator requires intrusion into the system to measure the refrigerant high-side and low-side pressures. Once the pressures are known, based on the equipment's refrigerant charging chart? or in most cases, based on the technician's experience? the refrigerant charging status is determined. However, there is a catch: by the time a refrigeration technician is called, most of the refrigerant has already escaped into the atmosphere. The new technology provides a real-time warning so that when, say, 20% of the refrigerant has leaked, the equipment users will be warned, even though the equipment is still functioning properly at rated capacity. Temperature sensors are becoming very accurate and very low in cost, compared with pressure sensors. Using temperature sensors to detect refrigerant charge status is inherently nonintrusive, inexpensive, and accurate. With the addition of two temperature sensors for detecting dirty air filters, the capability of the diagnostic equipment is further enhanced with very little added cost. This report provides laboratory test data on the change of indoor coil refrigerant temperature and subcooling as a function of refrigerant charge for a 2-ton split heat pump system. The data can be used in designing the indicators for refrigerant loss and dirty air filter sensors.

  20. air temperature air: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    air temperatures... conditions. The design of this study was based on the relation- ship of four parameters: air temperature, air velocity, radiant heat, and globe...

  1. General Air Permits (Louisiana)

    Broader source: Energy.gov [DOE]

    Any source, including a temporary source, which emits or has the potential to emit any air contaminant requires an air permit. Facilities with potential emissions less than 5 tons per year of any...

  2. Healthy Air Act (Maryland)

    Broader source: Energy.gov [DOE]

    The Maryland Healthy Air Act was developed with the purpose of bringing Maryland into attainment with the National Ambient Air Quality Standards (NAAQS) for ozone and fine particulate matter by the...

  3. Compressed Air Supply Efficiency 

    E-Print Network [OSTI]

    Joseph, B.

    2004-01-01T23:59:59.000Z

    COMPRESSED AIR SUPPLY EFFICENCY Babu Joseph, Ph.D., P.E. Engineer Southern California Edison Irwindale, CA ABSTRACT This project, under contract from California Energy Commission, developed the CASE (Compressed Air Supply Efficiency...

  4. Analysis of Potential Energy Saving and CO2 Emission Reduction of Home Appliances and Commercial Equipments in China

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    Multi-connected air condition (heat pump) unit Chiller VL VLmotors and air conditioners are followed by heat pump waterRefrigerator Heat Pump Water Heater Air Conditioner Electric

  5. Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2010

    E-Print Network [OSTI]

    Meyers, Stephen

    2013-01-01T23:59:59.000Z

    Commercial furnaces and boilers, air conditioners and heat pumps, and water heatersCOMMERCIAL & INDUSTRIAL EPACT 1992 Electric Motors EPACT 1992 Warm Air Furnaces EPACT 1992 Packaged Boilers EPACT 1992 Air Conditioners and Heat Pumps EPACT 1992 Water Heaters,

  6. Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 through 2012

    E-Print Network [OSTI]

    Meyers, Stephen

    2013-01-01T23:59:59.000Z

    Commercial furnaces and boilers, air conditioners and heat pumps, and water heatersCOMMERCIAL & INDUSTRIAL EPACT 1992 Electric Motors EPACT 1992 Warm Air Furnaces EPACT 1992 Packaged Boilers EPACT 1992 Air Conditioners and Heat Pumps EPACT 1992 Water Heaters,

  7. Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2011

    E-Print Network [OSTI]

    Meyers, Stephen

    2013-01-01T23:59:59.000Z

    Commercial furnaces and boilers, air conditioners and heat pumps, and water heatersCOMMERCIAL & INDUSTRIAL EPACT 1992 Electric Motors EPACT 1992 Warm Air Furnaces EPACT 1992 Packaged Boilers EPACT 1992 Air Conditioners and Heat Pumps EPACT 1992 Water Heaters,

  8. Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2013

    E-Print Network [OSTI]

    , Stephen Meyers

    2014-01-01T23:59:59.000Z

    Commercial furnaces and boilers, air conditioners and heat pumps, and water heatersCOMMERCIAL & INDUSTRIAL EPACT 1992 Electric Motors EPACT 1992 Warm Air Furnaces EPACT 1992 Packaged Boilers EPACT 1992 Air Conditioners and Heat Pumps EPACT 1992 Water Heaters,

  9. on man, nature & air pollution

    E-Print Network [OSTI]

    Finlayson-Pitts, Barbara J

    2008-01-01T23:59:59.000Z

    on man, nature & air pollution About three decades ago, itand episodes of air pollution the following summer. Wetthe increase in air pollution. This hypothesis generated

  10. MAD-AIR

    E-Print Network [OSTI]

    Tooley, J. J.; Moyer, N. A.

    1989-01-01T23:59:59.000Z

    with stress- related illness rather than the anwr that spells RELIEF. Air flow in, through ad arourd a house is an important concern in the building we call haw. !lb enhance air flow and change the various corditions or properties of the air, a variety...

  11. Air Quality Chapter Outline

    E-Print Network [OSTI]

    Wechsler, Risa H.

    Chapter 30 Air Quality Chapter Outline 1 Overview 2 1.1 Hazards / Impacts 2 1.2 Exposure Sources 3 Manual Chapter 30: Air Quality 7 References 20 8 Implementation 21 9 Ownership 22 1 Overview SLAC operations produce a wide range of air emissions. Sources of emissions include standard equipment

  12. Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles

    E-Print Network [OSTI]

    Xu, K.; Liu, M.; Wang, G.; Wang, Z.

    2007-01-01T23:59:59.000Z

    temperature at supply air temperature setpoint. Mechanical cooling is always required when outside air temperature is higher than the supply air temperature setpoint. Generally the supply air temperature setpoint is set at 55°F for space humidity control...

  13. A P P L I A N C E CEC 400-2005-012

    E-Print Network [OSTI]

    Test Methods........................... 44 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods....................... 45 C ............................................ 72 B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps................... 74

  14. A P P L I A N C E EFFICIENCY REGULATIONS

    E-Print Network [OSTI]

    Test Methods...........................40 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods ......................41 C............................................65 B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps..................67 B

  15. A P P L I A N C E August, 2003

    E-Print Network [OSTI]

    Test Methods........................... 40 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods....................... 41 C ............................................ 65 B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps................... 67

  16. Temperature, Power, and Makespan Aware Dependent Task Scheduling for Data Zheng Li, Li Wang, and Shangping Ren

    E-Print Network [OSTI]

    Quan, Gang

    conditioners are used to supply cold air and remove heat from the center. The supplied air must be cold enough of a server, the lower the temperature of cooling air provided by the air conditioner has to be. Unfortunately, as pointed out by Moore [4], lowing the room air conditioner's working temperature degrades its capability

  17. NREL's Energy-Saving Technology for Air Conditioning Cuts Peak Power Loads Without Using Harmful Refrigerants (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2012-07-01T23:59:59.000Z

    This fact sheet describes how the DEVAP air conditioner was invented, explains how the technology works, and why it won an R&D 100 Award. Desiccant-enhanced evaporative (DEVAP) air-conditioning will provide superior comfort for commercial buildings in any climate at a small fraction of the electricity costs of conventional air-conditioning equipment, releasing far less carbon dioxide and cutting costly peak electrical demand by an estimated 80%. Air conditioning currently consumes about 15% of the electricity generated in the United States and is a major contributor to peak electrical demand on hot summer days, which can lead to escalating power costs, brownouts, and rolling blackouts. DEVAP employs an innovative combination of air-cooling technologies to reduce energy use by up to 81%. DEVAP also shifts most of the energy needs to thermal energy sources, reducing annual electricity use by up to 90%. In doing so, DEVAP is estimated to cut peak electrical demand by nearly 80% in all climates. Widespread use of this cooling cycle would dramatically cut peak electrical loads throughout the country, saving billions of dollars in investments and operating costs for our nation's electrical utilities. Water is already used as a refrigerant in evaporative coolers, a common and widely used energy-saving technology for arid regions. The technology cools incoming hot, dry air by evaporating water into it. The energy absorbed by the water as it evaporates, known as the latent heat of vaporization, cools the air while humidifying it. However, evaporative coolers only function when the air is dry, and they deliver humid air that can lower the comfort level for building occupants. And even many dry climates like Phoenix, Arizona, have a humid season when evaporative cooling won't work well. DEVAP extends the applicability of evaporative cooling by first using a liquid desiccant-a water-absorbing material-to dry the air. The dry air is then passed to an indirect evaporative cooling stage, in which the incoming air is in thermal contact with a moistened surface that evaporates the water into a separate air stream. As the evaporation cools the moistened surface, it draws heat from the incoming air without adding humidity to it. A number of cooling cycles have been developed that employ indirect evaporative cooling, but DEVAP achieves a superior efficiency relative to its technological siblings.

  18. Air to Air Communication Protocol Arjan Durresi1

    E-Print Network [OSTI]

    Jain, Raj

    1 Air to Air Communication Protocol Arjan Durresi1 , Vamsi Paruchuri1 , Leonard Barolli2 and Raj. Louis, MO 63130, USA 314-935-4963, jain@cse.wustl.edu Abstract--We present Air to Air Communication (AAC........................................................2 3. AIR TO AIR COMMUNICATION..............................3 4. SIMULATIONS

  19. Mitigating the Impacts of Uncontrolled Air Flow on Indoor Environmental Quality and Energy Demand in Non-Residential Buildings

    SciTech Connect (OSTI)

    Hugh I. Henderson; Jensen Zhang; James B. Cummings; Terry Brennan

    2006-07-31T23:59:59.000Z

    This multi-faceted study evaluated several aspects of uncontrolled air flows in commercial buildings in both Northern and Southern climates. Field data were collected from 25 small commercial buildings in New York State to understand baseline conditions for Northern buildings. Laboratory wall assembly testing was completed at Syracuse University to understand the impact of typical air leakage pathways on heat and moisture transport within wall assemblies for both Northern and Southern building applications. The experimental data from the laboratory tests were used to verify detailed heat and moisture (HAM) simulation models that could be used to evaluate a wider array of building applications and situations. Whole building testing at FSEC's Building Science Laboratory (BSL) systematically evaluated the energy and IAQ impacts of duct leakage with various attic and ceiling configurations. This systematic test carefully controlled all aspects of building performance to quantify the impact of duct leakage and unbalanced flow. The newest features of the EnergyPlus building simulation tool were used to model the combined impacts of duct leakage, ceiling leakage, unbalanced flows, and air conditioner performance. The experimental data provided the basis to validate the simulation model so it could be used to study the impact of duct leakage over a wide range of climates and applications. The overall objective of this project was to transfer work and knowledge that has been done on uncontrolled air flow in non-residential buildings in Florida to a national basis. This objective was implemented by means of four tasks: (1) Field testing and monitoring of uncontrolled air flow in a sample of New York buildings; (2) Detailed wall assembly laboratory measurements and modeling; (3) Whole building experiments and simulation of uncontrolled air flows; and (4) Develop and implement training on uncontrolled air flows for Practitioners in New York State.

  20. Air Pollution- Local Air Quality (Ontario, Canada)

    Broader source: Energy.gov [DOE]

    The Air Pollution regulation administered by the Ministry of the Environment enforces compliance to the standards set in the Ontario law. The law is phased in, with portions taking effect in 2010,...

  1. ORIGINAL ARTICLE Ambient Air Pollution

    E-Print Network [OSTI]

    Mulholland, James A.

    ORIGINAL ARTICLE Ambient Air Pollution and Cardiovascular Emergency Department Visits Kristi Busico ambient air pollutants and cardiovascular disease (CVD), the roles of the physicochemical components the relation between ambient air pollution and cardiovascular conditions using ambient air quality data

  2. Air Pollution Control (Indiana)

    Broader source: Energy.gov [DOE]

    The mission of the Indiana Department of Environmental Management's Office of Air Quality implements federal and state regulations to protect human health and the environment while allowing the...

  3. Air Pollution Controls

    Broader source: Energy.gov [DOE]

    Various statutes within the Wisconsin Legislative Documents relate to air pollution control. These statutes describe zoning, permitting, and emissions regulations for hazardous and non-hazardous...

  4. Personal continuous air monitor

    DOE Patents [OSTI]

    Morgan, Ronald G. (Los Alamos, NM); Salazar, Samuel A. (Albuquerque, NM)

    2000-01-01T23:59:59.000Z

    A personal continuous air monitor capable of giving immediate warning of the presence of radioactivity has a filter/detector head to be worn in the breathing zone of a user, containing a filter mounted adjacent to radiation detectors, and a preamplifier. The filter/detector head is connected to a belt pack to be worn at the waist or on the back of a user. The belt pack contains a signal processor, batteries, a multichannel analyzer, a logic circuit, and an alarm. An air pump also is provided in the belt pack for pulling air through the filter/detector head by way of an air tube.

  5. Environmental Quality: Air (Louisiana)

    Broader source: Energy.gov [DOE]

    The Department of Environmental Quality regulates air quality in Louisiana. The Department has an established a fee system for funding the monitoring, investigation and other activities required...

  6. --------, UC-95d i i-' COPY

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    on national energy use are the electric centrifugal chiller, electric packaged and split air conditioners, oil chillers. The air conditioner market is dominated by small-sized units. The average size of air conditioner, air conditioning and ventilation (HVAC) requirements in commercial build- I ~ ings. According to the U

  7. AIR SEALING Seal air leaks and save energy!

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    AIR SEALING Seal air leaks and save energy! W H A T I S A I R L E A K A G E ? Ventilation is fresh air that enters a house in a controlled manner to exhaust excess moisture and reduce odors and stuffiness. Air leakage, or infiltration, is outside air that enters a house uncontrollably through cracks

  8. Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference

    E-Print Network [OSTI]

    Wechsler, Risa H.

    Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference Department: Chemical and General Safety Program: Air Quality Owner: Program Manager Authority: ES&H Manual, Chapter 30, Air Quality1 SLAC's air emissions are regulated through a federally mandated site-wide permit as well

  9. Compressed Air System Optimization

    E-Print Network [OSTI]

    Aegerter, R.

    Several years ago I went to a gas station and noticed that my car's tires were low on air. I saw the gas station had an air compressor, but it cost a quarter to use the compressor. I paid my quarter and used the compressor. I realized...

  10. Recirculating electric air filter

    DOE Patents [OSTI]

    Bergman, W.

    1985-01-09T23:59:59.000Z

    An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  11. Golden Opportunity: Proposed Penalty (2014-CE-20003)

    Broader source: Energy.gov [DOE]

    DOE alleged in a Notice of Proposed Civil Penalty that Golden Opportunity, Inc. failed to certify room air conditioners, central air conditioners/heat pumps, and residential clothes washers as compliant with the applicable energy conservation standards.

  12. Survey on Cooling Costs and Related Factors for Apartments in an Urban Area of Osaka 

    E-Print Network [OSTI]

    Umemiya, N.; Lin, X.; Inoue, G.

    2006-01-01T23:59:59.000Z

    A questionnaire survey was carried out to assess cooling behaviors and cooling costs for 290 apartments in an urban area. 1) Cooling costs are strongly related to the number of air conditioners, the months of occupation, and the air conditioner...

  13. Using National Survey Data to Estimate Lifetimes of Residential Appliances

    E-Print Network [OSTI]

    Lutz, James D.

    2013-01-01T23:59:59.000Z

    conditioners, heat pumps, furnaces, boilers, water heaters,conditioners, heat pumps, furnaces, boilers, water heaters,Water Heater, Gas Room Air- Conditioning Central Air- Conditioning Boiler, Gas Furnace, Gas Heat Pump *

  14. Research on Convective Heat Transfer and Mass Transfer of the Evaporator in Micro/Mini-Channel

    E-Print Network [OSTI]

    Su, J.; Li, J.

    2006-01-01T23:59:59.000Z

    on the reviewers on the present household air conditioners, the potential requirements for new heat transfer enhancement used for household air conditioners are discussed. Investigations on condensation and boiling of refrigerants in mini/micro channels have...

  15. Case Study of an Innovative HVAC System with Integral Dehumidifier

    E-Print Network [OSTI]

    Shirey, D. B.; Raustad, R. A.

    and humidistat. The dehumidification element of the system is completely independent from the air conditioner and works nearly the same as conventional dehumidification equipment. At times, both the dehumidification equipment and the air conditioner operate...

  16. http://pic.sagepub.com/ Engineering Science

    E-Print Network [OSTI]

    Pompili, Dario

    , i.e. computer room air conditioner fan failure, server fan failure, and workload misconfiguration events such as computer room air conditioner (CRAC) fan failure, server fan failure, and workload

  17. Two-Phase Cooling Method Using R134a Refrigerant to Cool Power Electronic Devices

    E-Print Network [OSTI]

    Tolbert, Leon M.

    configuration. Second, experimental tests that included simultaneous operation with a mock automotive air-conditioner, and a radiator. However, with slight modification to existing air-conditioner (A/C) systems in automobiles

  18. Chemical Emissions of Residential Materials and Products: Review of Available Information Improving Ventilation and Saving Energy: Final Report on

    E-Print Network [OSTI]

    with industry, a prototype improved heat pump air conditioner was developed to meet the specification. A one portable classrooms equipped with standard 10 SEER heat pump air conditioner equipment. The IHPAC units

  19. Topic 4: Demand Response A.H. MohsenianRad (U of T) 1Networking and Distributed Systems

    E-Print Network [OSTI]

    Mohsenian-Rad, Hamed

    : · The utility has remote access to certain load of users · Air conditioner · Water heater. · It remotely turns installed DLC switches on air conditioner #12;DLC Example Dr. Hamed Mohsenian-Rad Texas Tech University

  20. Name of TMO ODSS1 ODSS2

    E-Print Network [OSTI]

    Joo, Su-Chong

    Heating System Camera Window & Curtain LightFan Air Conditioner , , #12;Platform : Intel X86 /W indows XP /Windows 2000 Server CPU : Pentium 4-700MhzHome Server TMO Air Conditioner TMO Heater TMO Heater TMO Fan

  1. air volume air: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Air Preheat Economics Texas A&M University - TxSpace Summary: Retrofit air preheat systems are the most reliable and efficient means to effect significant energy...

  2. Abatement of Air Pollution: Hazardous Air Pollutants (Connecticut...

    Broader source: Energy.gov (indexed) [DOE]

    allowable stack concentrations and hazard limiting values for the emission of hazardous air pollutants. The regulations also discuss sampling procedures for hazardous air...

  3. Air Resources: Prevention and Control of Air Contamination and...

    Broader source: Energy.gov (indexed) [DOE]

    limits and permitting and operational requirements for facilities that may contribute to air emissions. General air quality standards and standards for specific contaminants are...

  4. Air Pollution Control Regulations: No. 7 - Emission of Air Contaminant...

    Broader source: Energy.gov (indexed) [DOE]

    with the enjoyment of life and property. The criteria for determining compliance is listed in the regulations, and is based on other air pollution and ambient air standards...

  5. Air ejector augmented compressed air energy storage system

    DOE Patents [OSTI]

    Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

    1980-01-01T23:59:59.000Z

    Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air pressure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

  6. Renewables and air quality

    SciTech Connect (OSTI)

    Wooley, D.R.

    2000-08-01T23:59:59.000Z

    The US heavy reliance on fossil fuels is a central obstacle to improving air quality and preventing catastrophic climate change. To solve this problem will require a combination of financial incentives and market rules that strongly encourage development of renewable energy resources to meet electric power demand. One promising policy option is to allow renewable energy resources to directly participate in air pollution emission trading mechanisms. Currently, the clean air benefits of renewable energy generally go unrecognized by regulators, under-appreciated by consumers and uncompensated by markets. Renewable energy is a key clean air alternative to conventional electricity generation, and the development of renewables could be stimulated by changes to the Clean Air Act's emissions trading programs. As Congress revisits clean air issues over the next several years, renewable energy representatives could push for statutory changes that reward the renewable energy industry for the air quality benefits it provides. By also becoming involved in key US Environmental Protection Agency (EPA) and state rule-making cases, the renewables industry could influence the structure of emissions trading programs and strengthen one of the most persuasive arguments for wind, solar and biomass energy development.

  7. Texas Clean Air Act (Texas)

    Broader source: Energy.gov [DOE]

    This Act is designed to safeguard the state's air resources from pollution by requiring the control and abatement of air pollution and emissions of air contaminants, consistent with the protection...

  8. Air Quality (Nova Scotia, Canada)

    Broader source: Energy.gov [DOE]

    Nova Scotia Environment is responsible for monitoring the air quality in the province, as well as administering fines and permits relating to air quality. The Air Quality Regulations state...

  9. Health Hazards in Indoor Air

    E-Print Network [OSTI]

    Logue, Jennifer M.

    2012-01-01T23:59:59.000Z

    Health Hazards in Indoor Air. In Proceedings of the 2010for VOCs from post-1990 indoor air concentration studies inUnion project on indoor air pollutants. Allergy, 2008. 63(

  10. Making Compressed Air System Decisions

    E-Print Network [OSTI]

    Porri, R. E.

    . The design of a compressed air system was formerly limited to the selection of an air compressor large enough to deliver sufficient compressed air for the estimated system requirements. As system air requirements grew, additional compressors were added... specification, selection and installation process will follow. BACKGROUND For more than 100 years compressed air has been used throughout industry as a safe and reliable utility. The generation of this utility is performed by an air compressor. The first...

  11. Air heating system

    DOE Patents [OSTI]

    Primeau, John J. (19800 Seminole Rd., Euclid, OH 44117)

    1983-03-01T23:59:59.000Z

    A self-starting, fuel-fired, air heating system including a vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with the provision of heat exchanger and circuitry for cooling the condensed fluid output from the pump prior to its return to the vapor generator.

  12. 2014-10-20 Issuance: ASRAC Regional Standards Enforcement Working...

    Energy Savers [EERE]

    Issuance Appliance Standards and Rulemaking Federal Advisory Committee (ASRAC) - Central Air Conditioner Regional Standards Enforcement Working Group; Notice of Open...

  13. Appliance Standards and Rulemaking Federal Advisory Committee...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Issuance Appliance Standards and Rulemaking Federal Advisory Committee (ASRAC) - Central Air Conditioner Regional Standards Enforcement Working Group; Notice of Open...

  14. 2014-08-19 Issuance Appliance Standards and Rulemaking Federal...

    Energy Savers [EERE]

    Issuance Appliance Standards and Rulemaking Federal Advisory Committee (ASRAC) - Central Air Conditioner Regional Standards Enforcement Working Group; Notice of Open...

  15. Office of the Assistant General Counsel for Enforcement | Department...

    Energy Savers [EERE]

    Standards and Certification Obligations West Coast Port Closure Enforcement Policy Central Air Conditioner Enforcement Policy Statement Regional Standards Enforcement Policy...

  16. Instrumented home energy rating and commissioning

    E-Print Network [OSTI]

    Wray, Craig P.; Walker, Iain S.; Sherman, Max H.

    2003-01-01T23:59:59.000Z

    air conditioner indicated that it is a 25 year old, low efficiency unit that is in need of replacement.

  17. Requirements Hydrocarbon

    E-Print Network [OSTI]

    Cinabro, David

    . He considered two coolants: Butane and R134a (freon replacement used in auto air conditioners). About

  18. EA-1637: Finding of No Significant Impact

    Broader source: Energy.gov [DOE]

    Energy Conservation Program for Commercial and Industrial Equipment: Packaged Terminal Air Conditioner and Packaged Terminal Heat Pump Energy Conservation Standards

  19. Energy for 500 Million Homes: Drivers and Outlook for Residential Energy Consumption in China

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01T23:59:59.000Z

    Heat Pump Air Conditioner District Heating Boiler Gas Boiler Electricity Figure 11 Space Heating Technology Shift in Residential

  20. Demand response enabling technology development

    E-Print Network [OSTI]

    2006-01-01T23:59:59.000Z

    battery voltage. NOTE: This device does not control the thermoelectric air conditioner on the plastic model house.

  1. TRANSPORTATION SERVICES VEHICLE RENTAL FEES

    E-Print Network [OSTI]

    ENVIRONMENT FEES AIR CONDITIONER SERVICE $75.00 PARTS + 10% BATTERY CHARGE $25.00 BATTERY REPLACEMENT $25

  2. Public Meeting: Physical Characterization of Grid-Connected Commercial...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and Definitions; Characterization Protocol Framework; Illustrative Example: Room Air Conditioner (RAC); Process for Developing Characterization Protocols; Overview of...

  3. August 2009 In this edition

    E-Print Network [OSTI]

    Shyy, Wei

    , air conditioner registration, key returns at move-out, etc.) · Sign-up for various events and programs

  4. Understanding the Dehumidification Performance of Air-Conditioning Equipment at Part-Load Conditions

    SciTech Connect (OSTI)

    Don B. Shirey III; Hugh I. Henderson Jr; Richard A. Raustad

    2006-01-01T23:59:59.000Z

    Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions--especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and may negatively impact indoor air quality. This report summarizes the results of a comprehensive project to better understand and quantify the moisture removal (dehumidification) performance of cooling coils at part-load conditions. A review of the open literature was initially conducted to learn from previous research on this topic. Detailed performance measurements were then collected for eight cooling coils in a controlled laboratory setting to understand the impact of coil geometry and operating conditions on transient moisture condensation and evaporation by the coils. Measurements of cooling coil dehumidification performance and space humidity levels were also collected at seven field test sites. Finally, an existing engineering model to predict dehumidification performance degradation for single-stage cooling equipment at part-load conditions (Henderson and Rengarajan 1996) was enhanced to include a broader range of fan control strategies and an improved theoretical basis for modeling off-cycle moisture evaporation from cooling coils. The improved model was validated with the laboratory measurements, and this report provides guidance for users regarding proper model inputs. The model is suitable for use in computerized calculation procedures such as hourly or sub-hourly building energy simulation programs (e.g., DOE's EnergyPlus building energy simulation program, http://www.energyplus.gov ).

  5. Air Cooling R&D

    Broader source: Energy.gov (indexed) [DOE]

    or otherwise restricted information. 2 State of the Art Everything on a vehicle is air cooled, ultimately... Air cooling can be done... When?... How? Honda Insight Power...

  6. Ambient Air Quality Standards (Iowa)

    Broader source: Energy.gov [DOE]

    These regulations set statewide ambient air quality standards for various contaminants. The state code follows the regulations set forth in the National Primary and Secondary Ambient Air Quality...

  7. Compressed Air Supply Efficiency

    E-Print Network [OSTI]

    Joseph, B.

    2004-01-01T23:59:59.000Z

    This project, under contract from California Energy Commission, developed the CASE (Compressed Air Supply Efficiency) Index as a stand-alone value for compressor central plant efficiency. This Index captures the overall efficiency of a compressed...

  8. Retrofit Air Preheat Economics

    E-Print Network [OSTI]

    Goolsbee, J. A.

    1981-01-01T23:59:59.000Z

    Retrofit air preheat systems are the most reliable and efficient means to effect significant energy conservation for large existing industrial furnaces. Units can be quickly installed without a lengthy shutdown, and the furnace efficiency can...

  9. Padding with Compressed Air

    E-Print Network [OSTI]

    Beals, C.

    2004-01-01T23:59:59.000Z

    We commonly find plants using padding to transport liquids or light solids short distances from tankers into storage tanks. Padding can wreck havoc in compressed air systems with limited storage, undersized cleanup equipment (dryers and filters...

  10. Canned Air in China

    E-Print Network [OSTI]

    Hacker, Randi

    2013-10-23T23:59:59.000Z

    Broadcast Transcript: Not that long ago, coal smoke made the air here in Beijing so caustic that your nasal passages were seared with each breath. Those were the good old days: Car ownership was limited to government ...

  11. Breathing zone air sampler

    SciTech Connect (OSTI)

    Tobin, John (Bethel Park, PA)

    1989-01-01T23:59:59.000Z

    A sampling apparatus is provided which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.

  12. Breathing zone air sampler

    SciTech Connect (OSTI)

    Tobin, J.

    1989-08-22T23:59:59.000Z

    A sampling apparatus is presented which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.

  13. Air pollution meteorology

    SciTech Connect (OSTI)

    Eagleman, J.R.

    1991-01-01T23:59:59.000Z

    Air Pollution Meteorology is divided into three parts: air pollution fundamentals; concentration calculations and distributions; and pollution and meteorological interactions. The first section includes chapters on the following topics: the problem; measurements, sources, and standards; air stagnation and pollutant index; and effects. The second section of the book includes chapters on diffusion theory, the Gaussian plume dispersion model, plume rise, various dispersion models, scale considerations, and concentration trends. The third and final section (on pollution and meteorological interactions) begins with two chapters on radiative and wind effects on dispersion, and then follows with chapters on acid rain, the ozone hole, the greenhouse effect, and nuclear winter. In summary, Air Pollution Meteorology does a good job of covering the field for physics, chemistry, and engineering students who want to obtain an overview of the subject.

  14. Air bag restraint device

    DOE Patents [OSTI]

    Marts, D.J.; Richardson, J.G.

    1995-10-17T23:59:59.000Z

    A rear-seat air bag restraint device is disclosed that prevents an individual, or individuals, from continuing violent actions while being transported in a patrol vehicle`s rear seat without requiring immediate physical contact by the law enforcement officer. The air bag is activated by a control switch in the front seat and inflates to independently restrict the amount of physical activity occurring in the rear seat of the vehicle while allowing the officer to safely stop the vehicle. The air bag can also provide the officer additional time to get backup personnel to aid him if the situation warrants it. The bag is inflated and maintains a constant pressure by an air pump. 8 figs.

  15. Utilities District of Western Indiana REMC- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Utilities District of Western Indiana REMC offers residential customers incentives for energy efficient heat pumps, water heaters, and air conditioners. Eligible air-source heat pump and air...

  16. 2006 Status Report Savings Estimates for the ENERGY STAR(R) Voluntary Labeling Program

    E-Print Network [OSTI]

    Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla; Homan, Gregory K.

    2006-01-01T23:59:59.000Z

    and Cooling - Furnace (Gas or Oil) - Central Air Conditioner - Air-Source Heat Pump - Geothermaland Cooling (HVAC). The HVAC program covers air-source heat pumps, geothermal

  17. Analysis of Potential Energy Saving and CO2 Emission Reduction of Home Appliances and Commercial Equipments in China

    E-Print Network [OSTI]

    Zhou, Nan

    2011-01-01T23:59:59.000Z

    Multi-connected air condition (heat pump) unit Chiller VL CRefrigerator Heat Pump Water Heater Air Conditioner ElectricHeat Pump Water Heater Standby TV Refrigerator Others* Air

  18. inAir: Sharing Indoor Air Quality Measurements and Visualizations

    E-Print Network [OSTI]

    Mankoff, Jennifer

    evidence has indicated that indoor air pollution within homes and other buildings can be worse than the outdoor air pollution in even the largest and most industrialized cities. For example, the California Air Resources Board estimates that indoor air pollutant levels are 25-62% greater than outside levels [4

  19. Clearing the Air: "AIR" Training Session Wednesday, December 18

    E-Print Network [OSTI]

    Reed, Christopher A.

    Clearing the Air: "AIR" Training Session Wednesday, December 18 12 p.m. ­ 1:00 p.m. Human Resources/Tobacco- Free! Join us for an interactive session and learn more about "AIR" (Approach, Inform, Refer, and safe campus environment. Visit Clearing the Air website (http://tobaccofree.ucr.edu/) for more

  20. Air distribution effectiveness with stratified air distribution systems

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    1 Air distribution effectiveness with stratified air distribution systems Kisup Lee* Zheng Jiang, Ph.D Qingyan Chen, Ph.D. Student Member ASHRAE Fellow ASHRAE ABSTRACT Stratified air distribution systems such as Traditional Displacement Ventilation (TDV) and Under- Floor Air Distribution (UFAD

  1. National Oceanic and Atmospheric Administration (NOAA) ExplorE thE EarthScience | Service | StewardshipScience | Service | Stewardship

    E-Print Network [OSTI]

    that is about 2 inches to 4 inches high r A replaceable air conditioner filter large enough to cover the box r conditioner filter at 1/2-inch intervals as shown in the "Air Conditioner Filter Grid" drawing. Label cement to fasten small objects to the inside bottom of the cardboard box. 2. Mark the sides of the air

  2. Math!. Comput. Modelling Vol. 23, No. 11/12, pp. 55-76. 1996 Copyright@1996 Elsevier Science Ltd

    E-Print Network [OSTI]

    Lemmon, Michael

    control system is the heating and cooling system of a typical home. The furnace and air conditioner, along and the thermostat's response is translated back to electrical currents which control the furnace, air conditioner that translate into commands to turn on or off the furnace or the air conditioner. This work was partially

  3. Georgia Institute of Technology Environmental Health and Safety

    E-Print Network [OSTI]

    ? Battery is free of leaks? Back-up alarm works? Windshield washer fluid? Heating, Air Conditioner of leaks? Back-up alarm works? Windshield washer fluid? Heating, Air Conditioner and Defroster works? Battery is free of leaks? Back-up alarm works? Windshield washer fluid? Heating, Air Conditioner

  4. Adaptive Reduction of Additive Noise From Sleep Breathing Sounds Tech Report: CSLU-2012-001

    E-Print Network [OSTI]

    Kain, Alexander

    of a sound classification sys- tem. Air conditioners and furnaces are typical sources of this type of noise in a home environment. During the course of a single night, an air conditioner or furnace may turn to sudden changes in the background noise (e. g. an air conditioner turning on), as well as overall

  5. 2102, Page 1 Experimental Investigation of Closed Loop Oscillating Heat Pipe as the

    E-Print Network [OSTI]

    Ghajar, Afshin J.

    pipe (CLOHP) as the condenser for a vapor compression refrigeration system. Split type air conditioner condenser in the split type air conditioner. The refrigeration capacity was set at 12,500 Btu/h (3.663 k is commonly used in a wide range of residential and commercial buildings. Most of the air conditioner types

  6. 1 Copyright 2007 by ASME Proceedings of IMECE 2007

    E-Print Network [OSTI]

    Texas at Arlington, University of

    EFFECTS ON AIR-CONDITIONER PERFORMANCE Matthew J. Sitzmann Haag Engineering, Co. 2455 McIver Lane.S.A. ssmith@haagengineering.com ABSTRACT Experiments demonstrated the effects on air-conditioner system-type air-conditioners were tested. Flattening substantial areas of the fins caused a reduc- tion

  7. STATE OF CALIFORNIA --NATURAL RESOURCES AGENCY EDMUND G. BROWN JR., Governor CALIFORNIA ENERGY COMMISSION

    E-Print Network [OSTI]

    of this Compliance Option application. Purpose Many air conditioners in California fail to achieve their rated problems. To reduce air conditioner energy consumption and peak demand, the Building Energy Efficiency the correct refrigerant charge and proper air conditioner system operation in residential buildings

  8. China Energy Efficiency Round Robin Testing Results for Room

    E-Print Network [OSTI]

    LBNL-3502E China Energy Efficiency Round Robin Testing Results for Room Air Conditioners Nan Zhou Berkeley National Laboratory is an equal opportunity employer. #12;i Table of Contents I. Air Conditioner.......................................................................................................................... 6 I.2.1 Necessity for Air Conditioner Round Robin Testing

  9. Acts of Commanding and Changing Obligations Tomoyuki Yamada

    E-Print Network [OSTI]

    Amsterdam, University of

    . There is a window and an air conditioner. You can open the window, or turn on the air conditioner. You can also does it affect the number of alternatives you have. It still is possible for you to turn on the air conditioner, to ignore the heat, or to open the window, of course. But it has now become impossible for you

  10. PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED INTO A DWELLING

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED.peuportier@mines-paristech.fr, Tel.: +33 1 40 51 91 51 ABSTRACT An inverter-driven air-to-air heat pump model has been developped capacity air-to-air heat pump coupled with temperate air sources (crawlspace, attic, sunspace, heat

  11. Air PSE (Problem Solving Environment)

    E-Print Network [OSTI]

    Nizkorodov, Sergey

    PSE - 1 Air PSE (Problem Solving Environment) MODELLING OF AIR POLLUTION IN THE LOS ANGELES BASIN WITH AIR PSE Developed by Prof. Donald Dabdub Computational Environmental Sciences Laboratory Mechanical COMPUTER MODELS An air pollution model is a computer program that computes how the different chemical

  12. Compressed air energy storage system

    DOE Patents [OSTI]

    Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

    1981-01-01T23:59:59.000Z

    An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

  13. Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature? 

    E-Print Network [OSTI]

    Wei, G.; Turner, W. D.; Claridge, D.; Liu, M.

    2002-01-01T23:59:59.000Z

    space area. Room temperatures are controlled by pneumatic thermostats. The AHU has a minimum outside air damper and a maximum outside air damper. The minimum outside air damper is fully open when the AHU is in operation. The maximum outside air... of thermostat, and the relationship between room temperature set point and return air temperature. The Role Of Thermostat Traditional pneumatic thermostat is a proportional (P) type controller. It senses the space temperature changes and produces...

  14. Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature?

    E-Print Network [OSTI]

    Wei, G.; Turner, W. D.; Claridge, D.; Liu, M.

    2002-01-01T23:59:59.000Z

    space area. Room temperatures are controlled by pneumatic thermostats. The AHU has a minimum outside air damper and a maximum outside air damper. The minimum outside air damper is fully open when the AHU is in operation. The maximum outside air... understand how this reset scheme responds to building load change, thus resulting in supply air temperature reset, it is helpful to explain the role of thermostat. In the following section, we explain the way how the thermostat works, the type...

  15. Design of RF Conditioner Cavities

    E-Print Network [OSTI]

    Govil, R.

    2008-01-01T23:59:59.000Z

    For most designs, the power loss at the cavity surface atheld fixed, the frequency, power loss and a more systematicwhile the cavity power loss (normalized by a factor of four

  16. Auxiliary air injector assembly

    SciTech Connect (OSTI)

    Sager, R.L.

    1987-04-07T23:59:59.000Z

    This patent describes an auxiliary air injector assembly kit for replacement use to connect a secondary air line from an engine air pump to an exhaust pipe in a variety of combustion engine exhaust systems. The exhaust pipe has an auxiliary air receiving hole formed in a wall thereof. The assembly comprises a flexible conduit adapted to be readily cut to length and connected at one end to the secondary air line, a metal tube, means for connecting a first end of the metal tube to the other end of the flexible conduit, and a hollow fitting with an air flow-through passage and having a conical portion adapted to fit in the hole in a leak resistant manner. The fitting has a bearing portion with a convex spherical surface located outside the exhaust pipe when the conical portion is in the hole. A second end of the metal tube has a flange with a concave spherical surface to seat against the convex spherical surface in a leak resistant manner. A clamp means connects the metal tube to the exhaust pipe and applies pressure on the metal tube flange against the bearing portion of the fitting to hold the fitting in the hole. The clamp means includes a saddle having an opening larger than the tube but smaller than the tube flange. The tube extends through the saddle opening. The clamp means also includes a U-bolt assembly for extending around the exhaust pipe and forcing the saddle against the tube flange and toward the exhaust pipe.

  17. Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York)

    Broader source: Energy.gov [DOE]

    These regulations establish emissions limits and permitting and operational requirements for facilities that may contribute to air emissions. General air quality standards and standards for...

  18. Vermont Air Pollution Control Regulations, Ambient Air Quality Standards (Vermont)

    Broader source: Energy.gov [DOE]

    The ambient air quality standards are based on the national ambient air quality standards. The Vermont standards are classified as primary and secondary standards and judged adequate to protect...

  19. Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics

    E-Print Network [OSTI]

    Graham, E. L.

    1980-01-01T23:59:59.000Z

    Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

  20. Compressed Air 101: Getting Compressed Air to Work

    E-Print Network [OSTI]

    Burke, J. J.; Bessey, E. G.

    "Air compressors are a significant industrial energy user. Based on a survey (conducted by Oregon State University and the Bonneville Power Administration) of energy audit reports from 125 plants, air compressors account for roughly 10% of total...

  1. A Homeowners Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet), Building America Case Study: Technology Solutions for Existing Homes, Building Technologies Office (BTO)

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO Overview OCHCOSystems AnalysisVOLUMEStatement of Warren F.States:

  2. Cold Air Distribution in Office Buildings: Technology Assessment for California

    E-Print Network [OSTI]

    Bauman, F.S.

    2008-01-01T23:59:59.000Z

    warmer room air with the cold supply air whenever the supplyroom air diffusion with cold supply air temperatures under

  3. The investigation of exhaust powered, automotive air cycle air conditioning 

    E-Print Network [OSTI]

    Holley, James Andrew

    1978-01-01T23:59:59.000Z

    TEE INVESTIGATION OF EXHAUST POWERED, AUTOMOTIVE AIR CYCLE AIR CONDITIONING A Thesis James Andrew Holley Submitted to the Graduate College of Texas ASM University in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE... August 1978 Major SubJect: Mechanical Engineering THE INVESTIGATION OF EXHAUST POWERED, AUTOMOTIVE AIR CYCLE AIR CONDITIONING A Thesis hy James Andrew Holley Approved as to style and content by: Chairman of Committee) (Head of Departm nt) Memb e...

  4. Environmental Pollution Air Pollution Dispersion Practical Air Pollution Dispersion

    E-Print Network [OSTI]

    Moncrieff, John B.

    Environmental Pollution Air Pollution Dispersion 1 of 5 Practical ­ Air Pollution Dispersion in the lectures how such models can be used to explain observed concentrations of air pollutants in an area and to test `what-if' scenarios for pollution control and reduction. You will use the Gaussian Plume Model

  5. Louisiana Air Control Law (Louisiana)

    Broader source: Energy.gov [DOE]

    This law states regulations for air quality control and states the powers and duties of the secretary of environmental quality. It provides information about permits and licenses, air quality...

  6. Tennessee Air Quality Act (Tennessee)

    Broader source: Energy.gov [DOE]

    The Tennessee Air Quality Act (AQA) delegates the power to maintain air quality in the State to the Department of Environment and Conservation. Under the Department of the Environment and...

  7. Air Pollution Control Fees (Ohio)

    Broader source: Energy.gov [DOE]

    Facilities with a potential to emit any one regulated air pollutant of a quantity greater than or equal to 100 tons per year, or any one hazardous air pollutant (HAP) greater than or equal to 10...

  8. Compressed Air Audits using AIRMaster

    E-Print Network [OSTI]

    Wheeler, G. M.; McGill, R. D.; Bessey, E. G.; Vischer, K.

    Air compressors are a significant industrial energy user and therefore a prime target for industrial energy audits. The project goal was to develop a software tool, AIRMaster, and supporting methodology for performing compressed air system audits...

  9. Fundamentals of Compressed Air Systems

    Office of Energy Efficiency and Renewable Energy (EERE)

    Find out how a compressed air system works and the benefits of optimal compressed air system performance. This initial class demonstrates how to compute the current cost of your plant's compressed...

  10. COMBUSTION-GENERATED INDOOR AIR POLLUTION

    E-Print Network [OSTI]

    Hollowell, C.D.

    2010-01-01T23:59:59.000Z

    The Status of Indoor Air Pollution Research 1976. Geometand appliances and air pollution levels in the indoorAnnual Meeting of the Air Pollution Control Association,

  11. COMBUSTION-GENERATED INDOOR AIR POLLUTION

    E-Print Network [OSTI]

    Hollowell, C.D.

    2011-01-01T23:59:59.000Z

    The Japanese Union of Air Pollution Prevention Associations,The Status of Indoor Air Pollution Research 1976, GeometAnnual Meeting of the Air Pollution Control Association,

  12. Review: Integrating Climate, Energy and Air Pollution

    E-Print Network [OSTI]

    Toohey, David E.

    2013-01-01T23:59:59.000Z

    Climate, Energy and Air Pollution By Gary Bryner with RobertEnergy, and Air Pollution. Cambridge, Massachusetts, The MITClimate, Energy, and Air Pollution provides a well-

  13. Radionuclide Air Emission Report for 2011

    E-Print Network [OSTI]

    Wahl, Linnea

    2012-01-01T23:59:59.000Z

    LBNL-470E-20Ì1 Radionuclide Air Emission Report for Preparedfor Estimating Fugitive Air Emissions of Radionuclides fromStandards for Hazardous Air Pollutants (Radionuclides),

  14. Oil and Gas Air Heaters 

    E-Print Network [OSTI]

    Kou, G.; Wang, H.; Zhou, J.

    2006-01-01T23:59:59.000Z

    , the relation of hot-air temperature, oil or gas consumption and fresh airflow is determined based on energy equilibrium....

  15. Oil and Gas Air Heaters

    E-Print Network [OSTI]

    Kou, G.; Wang, H.; Zhou, J.

    2006-01-01T23:59:59.000Z

    , the relation of hot-air temperature, oil or gas consumption and fresh airflow is determined based on energy equilibrium....

  16. TTProblem A Air Conditioning Machinery

    E-Print Network [OSTI]

    California at Berkeley, University of

    TTProblem A Air Conditioning Machinery Input file: ducts.in You are a technician for the Air Conditioning Machinery company (ACM). Unfortunately, when you arrive at a customer site to install some air conditioning ducts, you discover that you are running low on supplies. You have only six duct segments

  17. Air Pollution Socio-Economic

    E-Print Network [OSTI]

    Minnesota, University of

    Traffic Air Pollution and Socio-Economic Status Gregory C Pratt PhD Kristie Ellickson PhD #12 · Relationships #12;Living near traffic increases exposure to air pollution and is associated with adverse health exposed to traffic and air pollution. They are also more vulnerable and have an increased risk of adverse

  18. FLUIDIC: Metal Air Recharged

    ScienceCinema (OSTI)

    Friesen, Cody

    2014-04-02T23:59:59.000Z

    Fluidic, with the help of ARPA-E funding, has developed and deployed the world's first proven high cycle life metal air battery. Metal air technology, often used in smaller scale devices like hearing aids, has the lowest cost per electron of any rechargeable battery storage in existence. Deploying these batteries for grid reliability is competitive with pumped hydro installations while having the advantages of a small footprint. Fluidic's battery technology allows utilities and other end users to store intermittent energy generated from solar and wind, as well as maintain reliable electrical delivery during power outages. The batteries are manufactured in the US and currently deployed to customers in emerging markets for cell tower reliability. As they continue to add customers, they've gained experience and real world data that will soon be leveraged for US grid reliability.

  19. Air Observe System

    E-Print Network [OSTI]

    Alexander Bolonkin

    2007-01-10T23:59:59.000Z

    This manuscript contains a description and basic principles for observing inaccessible areas using low cost, easily deployed equipment. The basic premise is to suspend a tiny video camera at an altitude of 10 - 200 meters over the area to be surveyed. The TV camera supports at altitude by wind or balloon. The technical challenges regard the means by which the camera is suspended. Such a system may be used by military or police forces or by civil authorities for rescue missions or assessment of natural disasters. The method may be further developed for military applications by integrating the surveillance task with deployment of munitions. Key words: air observer, air suspended system, low altitude video observer.

  20. FLUIDIC: Metal Air Recharged

    SciTech Connect (OSTI)

    Friesen, Cody

    2014-03-07T23:59:59.000Z

    Fluidic, with the help of ARPA-E funding, has developed and deployed the world's first proven high cycle life metal air battery. Metal air technology, often used in smaller scale devices like hearing aids, has the lowest cost per electron of any rechargeable battery storage in existence. Deploying these batteries for grid reliability is competitive with pumped hydro installations while having the advantages of a small footprint. Fluidic's battery technology allows utilities and other end users to store intermittent energy generated from solar and wind, as well as maintain reliable electrical delivery during power outages. The batteries are manufactured in the US and currently deployed to customers in emerging markets for cell tower reliability. As they continue to add customers, they've gained experience and real world data that will soon be leveraged for US grid reliability.

  1. Air cathode structure manufacture

    DOE Patents [OSTI]

    Momyer, William R. (Palo Alto, CA); Littauer, Ernest L. (Los Altos Hills, CA)

    1985-01-01T23:59:59.000Z

    An improved air cathode structure for use in primary batteries and the like. The cathode structure includes a matrix active layer, a current collector grid on one face of the matrix active layer, and a porous, nonelectrically conductive separator on the opposite face of the matrix active layer, the collector grid and separator being permanently bonded to the matrix active layer. The separator has a preselected porosity providing low IR losses and high resistance to air flow through the matrix active layer to maintain high bubble pressure during operation of the battery. In the illustrated embodiment, the separator was formed of porous polypropylene. A thin hydrophobic film is provided, in the preferred embodiment, on the current collecting metal grid.

  2. Potential Impact of Adopting Maximum Technologies as Minimum Efficiency Performance Standards in the U.S. Residential Sector

    E-Print Network [OSTI]

    Letschert, Virginie

    2010-01-01T23:59:59.000Z

    central air conditioners, water heaters and furnaces) areair conditioners, water heaters and furnaces) UnregulatedM i l l o 10 i n s 2. Water Heaters DOE has issued a final

  3. DEMONSTRATION wcec.ucdavis.edu

    E-Print Network [OSTI]

    California at Davis, University of

    Conditioner Diagnostics & Service Western Cooling Efficiency Center Jonathan Woolley jmwoolley, which is correlated to external static pressure measurements. This data can be used to determine cool to eval- uate system performance of conventional air conditioners in commercial facilities. Through

  4. Data:D00bb266-0005-47c0-bb95-126e7005bc70 | Open Energy Information

    Open Energy Info (EERE)

    conditioners of Cooperative members subject to the following criteria: Criteria: (a) The air conditioner must be a central system and not a window or wall unit. (b) Usage pattern...

  5. Air Risk Information Support Center

    SciTech Connect (OSTI)

    Shoaf, C.R.; Guth, D.J. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31T23:59:59.000Z

    The Air Risk Information Support Center (Air RISC) was initiated in early 1988 by the US Environmental Protection Agency`s (EPA) Office of Health and Environmental Assessment (OHEA) and the Office of Air Quality Planning and Standards (OAQPS) as a technology transfer effort that would focus on providing information to state and local environmental agencies and to EPA Regional Offices in the areas of health, risk, and exposure assessment for toxic air pollutants. Technical information is fostered and disseminated by Air RISCs three primary activities: (1) a {open_quotes}hotline{close_quotes}, (2) quick turn-around technical assistance projects, and (3) general technical guidance projects. 1 ref., 2 figs.

  6. Electrocatalysts for Nonaqueous Lithium–Air Batteries:...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Electrocatalysts for Nonaqueous Lithium–Air Batteries: Status, Challenges, and Perspective. Electrocatalysts for Nonaqueous Lithium–Air Batteries: Status, Challenges,...

  7. Alliant Energy Interstate Power and Light (Electric) - Residential...

    Broader source: Energy.gov (indexed) [DOE]

    Pumps Lighting Program Info State Iowa Program Type Utility Rebate Program Rebate Amount Central Air Conditioners: 100 - 200 Air Source Heat Pumps: 100 - 400 Geothermal Heat...

  8. DOE Facilitates Market-Driven Solutions to Develop and Deploy...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Launches Better Buildings Alliance Indoor Lighting Campaign for Commercial Buildings Central air conditioners circulate cool air through a system of supply and return ducts. |...

  9. Enforcement Policy Statement: Off Mode Standards for Central...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Enforcement Policy Statement: Off Mode Standards for Central Air Conditioners and Central Air Conditioning Heat Pumps July 8, 2014 On June 27, 2011, the Department of Energy (DOE)...

  10. Tax Credits, Rebates & Savings | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    provides its residential customers with rebates for geothermal and air source heat pumps, central air conditioners, and new high... Eligibility: Residential Savings Category: Heat...

  11. Golden Opportunity: Order (2014-CE-20003) | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Golden Opportunity had failed to certify that certain models of room air conditioners, central air conditionersheat pumps, and residential clothes washers comply with the...

  12. Department of Energy Opens Appliance Standards Investigation...

    Energy Savers [EERE]

    that it has opened an investigation to determine whether certain air conditioners and heat pump products manufactured by Air Con International comply with federal energy efficiency...

  13. Tax Credits, Rebates & Savings | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Furnaces, Boilers, Air conditioners, Heat recovery, Steam-system upgrades, Compressed air, Building Insulation, Motor VFDs, Processing and Manufacturing Equipment, Custom...

  14. Tax Credits, Rebates & Savings | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Lighting, Lighting ControlsSensors, Chillers, Heat Pumps, Air conditioners, Compressed air, Energy Mgmt. SystemsBuilding Controls, Motors, Motor VFDs, Agricultural Equipment,...

  15. CX-012123: Categorical Exclusion Determination | Department of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    "through-the-wall central air conditioner" and "through-the-wall central air conditioning heat pump" that were established in section 5 of the American Energy Manufacturing...

  16. The Path to Savings: Understanding the Federal Purchase of Energy-Consuming Products

    E-Print Network [OSTI]

    Taylor, Margaret

    2014-01-01T23:59:59.000Z

    Commercial Air-Source Heat Pumps $3K – 25K Commercial Boilers 3K – 25K A Commercial Central Air Conditioners >$25K Commercial Gas Water Heaters

  17. Heat Controller: Noncompliance Determination (2014-SE-15004)...

    Office of Environmental Management (EM)

    a Notice of Noncompliance Determination to Heat Controller, Inc. finding that the room air conditioner distributed in commerce by Heat Controller as Comfort Aire brand models...

  18. Regenerative air heater

    DOE Patents [OSTI]

    Hasselquist, P.B.; Baldner, R.

    1980-11-26T23:59:59.000Z

    A gas-cooled steel skirt is used to support a refractory cored brick matrix and dome structure in a high temperature regenerative air heater useful in magnetohydrodynamic power generation. The steel skirt thermally expands to accommodate the thermal expansion of the dome structure despite substantial temperature differential thereby reducing relative movement between the dome bricks. Gas cooling of the steel skirt allows the structure to operate above its normal temperature during clean-out cycles and also allows for the control of the thermal expansion of the steel skirt.

  19. Hot air drum evaporator

    DOE Patents [OSTI]

    Black, Roger L. (Idaho Falls, ID)

    1981-01-01T23:59:59.000Z

    An evaporation system for aqueous radioactive waste uses standard 30 and 55 gallon drums. Waste solutions form cascading water sprays as they pass over a number of trays arranged in a vertical stack within a drum. Hot dry air is circulated radially of the drum through the water sprays thereby removing water vapor. The system is encased in concrete to prevent exposure to radioactivity. The use of standard 30 and 55 gallon drums permits an inexpensive compact modular design that is readily disposable, thus eliminating maintenance and radiation build-up problems encountered with conventional evaporation systems.

  20. Regenerative air heater

    DOE Patents [OSTI]

    Hasselquist, Paul B. (Maple Grove, MN); Baldner, Richard (Minnetonka, MN)

    1982-01-01T23:59:59.000Z

    A gas-cooled steel skirt is used to support a refractory cored brick matrix and dome structure in a high temperature regenerative air heater useful in magnetohydrodynamic power generation. The steel skirt thermally expands to accommodate the thermal expansion of the dome structure despite substantial temperature differential thereby reducing relative movement between the dome bricks. Gas cooling of the steel skirt allows the structure to operate above its normal temperature during clean-out cycles and also allows for the control of the thermal expansion of the steel skirt.