Powered by Deep Web Technologies
Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Air Conditioner Compressor Performance Model  

SciTech Connect (OSTI)

During the past three years, the Western Electricity Coordinating Council (WECC) Load Modeling Task Force (LMTF) has led the effort to develop the new modeling approach. As part of this effort, the Bonneville Power Administration (BPA), Southern California Edison (SCE), and Electric Power Research Institute (EPRI) Solutions tested 27 residential air-conditioning units to assess their response to delayed voltage recovery transients. After completing these tests, different modeling approaches were proposed, among them a performance modeling approach that proved to be one of the three favored for its simplicity and ability to recreate different SVR events satisfactorily. Funded by the California Energy Commission (CEC) under its load modeling project, researchers at Pacific Northwest National Laboratory (PNNL) led the follow-on task to analyze the motor testing data to derive the parameters needed to develop a performance models for the single-phase air-conditioning (SPAC) unit. To derive the performance model, PNNL researchers first used the motor voltage and frequency ramping test data to obtain the real (P) and reactive (Q) power versus voltage (V) and frequency (f) curves. Then, curve fitting was used to develop the P-V, Q-V, P-f, and Q-f relationships for motor running and stalling states. The resulting performance model ignores the dynamic response of the air-conditioning motor. Because the inertia of the air-conditioning motor is very small (H<0.05), the motor reaches from one steady state to another in a few cycles. So, the performance model is a fair representation of the motor behaviors in both running and stalling states.

Lu, Ning; Xie, YuLong; Huang, Zhenyu

2008-09-05T23:59:59.000Z

2

Improving Air-Conditioner and Heat Pump Modeling (Presentation)  

SciTech Connect (OSTI)

A new approach to modeling residential air conditioners and heat pumps allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted 'behind-the-scenes' without negatively impacting the reliability of energy simulations.

Winkler, J.

2012-03-01T23:59:59.000Z

3

Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations  

SciTech Connect (OSTI)

This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost effective equipment upgrade opportunities and efficiency improvements in residential buildings.

Cutler, D.; Winkler, J.; Kruis, N.; Christensen, C.; Brendemuehl, M.

2013-01-01T23:59:59.000Z

4

Assessing the Impact of Measurement Policy on the Accuracy of Certified Energy Efficiency Ratio for Split-System Air Conditioners  

E-Print Network [OSTI]

Efficiency of Unitary Air Conditioners and Heat Pumps,and Validation of Unitary Air Conditioner and Heat PumpC.W. (1994). Room Air Conditioner System Modeling, Air

Yu, Bingyi

2013-01-01T23:59:59.000Z

5

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network [OSTI]

Baseline Efficient Air Conditioners . . . . . . 28 AverageEfficient Air Conditioners . . . . . . . . . . . . . . . . .Btu/h Commercial Air Conditioners . . . . . . . . . . . . .

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

6

APPROVED ICE STORAGE AIR CONDITIONERS Revised as of 06-18-2008  

E-Print Network [OSTI]

APPROVED ICE STORAGE AIR CONDITIONERS Revised as of 06-18-2008 The following vendors and their ice storage air conditioners models can be used in the ice storage air conditioner compliance option. Input

7

Model-Based Commissioning for Filters in Room Air Conditioners  

E-Print Network [OSTI]

This paper proposes a model that can estimate filter resistance. Two sorts of value are used as inputs to estimate filter resistance. One is the power consumed by the fan in the indoor unit and the other is the thermal performance. For the room air...

Wang, F.; Yoshida, H.; Kitagawa, H.; Matsumoto, K.; Goto, K.

2004-01-01T23:59:59.000Z

8

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network [OSTI]

Products: Central Air Conditioners and Heat Pumps Energyof Improved Central Air Conditioner Efficiencies Authorsresidential-type central air conditioner energy-efficiency

Rosenquist, G.

2010-01-01T23:59:59.000Z

9

Dirty air conditioners: Energy implications of coil fouling  

E-Print Network [OSTI]

1473. Neal, L. 1992. Air Conditioner Efficiency in the Realof a Residential Air Conditioner. Proceedings of the 1992of new residential air conditioners in Phoenix, Arizona.

Siegel, Jeffrey; Walker, Iain; Sherman, Max

2002-01-01T23:59:59.000Z

10

DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS  

E-Print Network [OSTI]

DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS K. Dao, M.ABSORPTION AIR CONDITIONERS AND HEAT PUMPS* K. DAO, M.

Dao, K.

2013-01-01T23:59:59.000Z

11

Modeling the effects of Refrigerant Charging on Air Conditioner Performance Characteristics For Three Expansion Devices  

E-Print Network [OSTI]

An experimental and analytical study concerned with the off-design refrigerant charging of air conditioners is presented. A series of experiments were conducted to characterize the effects of refrigerant charge and type of expansion device...

Farzad, Mohsen

12

AIR CONDITIONER REQUEST EXTREME MEDICAL CIRCUMSTANCES  

E-Print Network [OSTI]

AIR CONDITIONER REQUEST DUE TO EXTREME MEDICAL CIRCUMSTANCES TO BE COMPLETED BY ATTENDING Moderate Significant Is the use of an air conditioner desirable Yes No OR essential Yes No to the management of allergy? Is the use of an air conditioner

13

Development of a room air conditioner design model  

E-Print Network [OSTI]

AND RECOMMENDATIONS. Page . 12 . 12 . 20 . 33 . 38 . 48 . 50 . 56 Conclusions. Recommendations. REFERENCES APPENDIX A . 57 . 57 . 59 . 61 VITA . 66 LZST OP TABLES Table Page 2. 1 Major output parameters from the ORNL model 3. 1 Effect of tube.... Efficiency improvements are evaluated with the aid of a computer model. The model chosen for this analysis was the Oak Ridge National Laboratory (ORNL) heat pump model [5] . The ORNL Heat Pump Design Model is a FORTRAN computer program developed...

Penson, Steven Brad

1988-01-01T23:59:59.000Z

14

High-Efficiency Window Air Conditioners - Building America Top...  

Broader source: Energy.gov (indexed) [DOE]

Window Air Conditioners - Building America Top Innovation This photo shows a window air conditioning unit in place in a window frame. Window air conditioners are inexpensive,...

15

Modeling of a second-generation solar-driven Rankine air conditioner. Final report  

SciTech Connect (OSTI)

Ten configurations of a second-generation (2G), solar-powered, Rankine-driven air conditioner were simulated and the data presented for use in companion studies. The results of the analysis show that the boiling-in-collector (BIC) configuration generates more power per collector area than the other configurations. The models used to simulate the configuration are presented in this report. The generated data are also presented. Experimental work was done under this study to both improve a novel refrigerant and oil lubrication system for the centrifugal compressor and investigate the aerodynamic unloading characteristics of the centrifugal compressor. The information generated was used to define possible turbo-gearbox configurations for use in the second generation computer simulation.

Denius, M.W.; Batton, W.D.

1984-07-01T23:59:59.000Z

16

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner...  

Energy Savers [EERE]

Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models...

17

Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners  

E-Print Network [OSTI]

Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners John Shugars, Consultant ofcommercialpackaged air conditioners, explore the reasons behindthis efficiency gap, and assess opportunities). Although sales of rooftop air conditioners have steadily increased over the past decade, the efficiency

18

DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS  

E-Print Network [OSTI]

SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS K.Driven Absorption Air-Conditioner", K. Dao, M. Simmons, R.SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS* K.

Dao, K.

2013-01-01T23:59:59.000Z

19

Electrolux Gibson Air Conditioner and Equator Clothes Washer...  

Broader source: Energy.gov (indexed) [DOE]

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing...

20

Natural Gas Heat Pump and Air Conditioner | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Natural Gas Heat Pump and Air Conditioner Natural Gas Heat Pump and Air Conditioner Lead Performer: Thermolift - Stony Brook, NY Partners: -- New York State Energy Research &...

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

An Analysis of Efficiency Improvements in Room Air Conditioner  

E-Print Network [OSTI]

NAECA NATIONAL APPLIANCE ENERGY CONSERVATION ACT NBS NATIONAL BUREAU OF STANDARDS NECPA NATIONAL ENERGY CONSERVATION POLICY ACT NTU NUMBER OF TRANSFER UNITS OEM ORIGINAL EQUIPMENT MANUFACTURER ORNL OAK RIDGE NATIONAL LABORATORY RAC ROOM AIR CONDITIONER.... There are two public domain models that we have considered using for this analysis: the Oak Ridge National Laboratory (ORNL) heat pump model [1] and the Arthur D. Little (ADL) room air conditioner model [2]. The ORNL model was completed in 1981. Although...

O'Neal, D. L.; Penson, S. B.

1988-01-01T23:59:59.000Z

22

Four Central Air Conditioners Determined Noncompliant With Energy...  

Broader source: Energy.gov (indexed) [DOE]

Heat Pumps DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards DOE Orders AeroSys to Halt...

23

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

Blast-Type Air Conditioners and Heat Pump. The correspondingair/air air conditioners and heat pumps. Some improvementsconnected air- conditioner (heat pump) units, household

Zhou, Nan

2010-01-01T23:59:59.000Z

24

Modeled and measured effects of compressor downsizing in an existing air conditioner/heat pump in the cooling mode  

SciTech Connect (OSTI)

It is not uncommon to find oversized central air conditioners in residences. HVAC contractors sometimes oversize central air conditioners for one reason or another--some to the point that they may be 100% larger than needed to meet the load. Retrofit measures done to improve house envelope and distribution system efficiency also contribute to HVAC oversizing, as they reduce house heating and cooling loads. Proper sizing of an air conditioner or heat pump allows more efficient operation and provides a more comfortable environment than a highly oversized unit. Another factor that lowers operating efficiency is an improper refrigerant charge. Field inspections have revealed that about half of the units checked were not properly charged. An option available to homeowners with oversized air conditioners is to replace the existing compressor with a smaller, more efficient compressor, rather than purchasing a new, smaller unit. Such a retrofit may be economically justified, especially during a compressor failure, provided the oversizing of the existing unit is not too great. A used, 15-year old, single-package heat pump with a capillary tube expansion device on the indoor coil was purchased and tested in a set of environmental chambers to determine its cooling performance at various conditions. The system was also modeled to estimate its existing performance, and that with two different types of retrofitted state-of-the-art (SOA) efficient compressors with about 30% less capacity than the original compressor. This reduced the overall system cooling capacity by about 25%. Modeling estimated that the retrofit would increase system EER at 95 F by 30%, SEER by 34%, and reduce power demand by 39% compared to the existing unit. Reduced cycling losses account for the higher increase in SEER.

Levins, W.P.; Rice, C.K.; Baxter, V.D.

1996-05-01T23:59:59.000Z

25

Covered Product Category: Residential Central Air Conditioners...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

operate on single-phase current and have cooling capacities less than 65,000 Btuh. Room air conditioners (window and through-the-wall) are covered by a separate specification,...

26

Rating of Mixed Split Residential Air Conditioners  

E-Print Network [OSTI]

A methodology is presented for rating the performance of mixed, split residential air conditioners. The method accounts for the impact on system performance of the indoor evaporator, expansion device and fan; three major components that are likely...

Domanski, P. A.

1988-01-01T23:59:59.000Z

27

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

Results for Room Air Conditioners Nan Zhou David FridleyTable of Contents I. Air Conditioner Round Robin TestingAir Conditioners..

Zhou, Nan

2010-01-01T23:59:59.000Z

28

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

E-Print Network [OSTI]

Measuring Short-term Air Conditioner Demand Reductions forMeasuring Short-term Air Conditioner Demand Reductions forpilots have shown that air conditioner (AC) electric loads

Bode, Josh

2013-01-01T23:59:59.000Z

29

Technical and economic analysis of energy efficiency of Chinese room air conditioners  

E-Print Network [OSTI]

Sector Study of Room Air Conditioners in China) , ChinaQi Shichang ( China’s Air Conditioner Market ), China Lightand Constant-Speed Air Conditioners." ASHRAE Transactions.

Fridley, David G.; Rosenquist, Gregory; Jiang, Lin; Li, Aixian; Xin, Dingguo; Cheng, Jianhong

2001-01-01T23:59:59.000Z

30

Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners  

E-Print Network [OSTI]

Final Summary Report by Air Conditioner Evaluation Standardreversible residential air conditioners and heat pumps usingJFS, 2007: “New Air Conditioners with Infrared Sensors

Shah, Nihar

2014-01-01T23:59:59.000Z

31

Stirling Air Conditioner for Compact Cooling  

SciTech Connect (OSTI)

BEETIT Project: Infinia is developing a compact air conditioner that uses an unconventional high efficient Stirling cycle system (vs. conventional vapor compression systems) to produce cool air that is energy efficient and does not rely on polluting refrigerants. The Stirling cycle system is a type of air conditioning system that uses a motor with a piston to remove heat to the outside atmosphere using a gas refrigerant. To date, Stirling systems have been expensive and have not had the right kind of heat exchanger to help cool air efficiently. Infinia is using chip cooling technology from the computer industry to make improvements to the heat exchanger and improve system performance. Infinia’s air conditioner uses helium gas as refrigerant, an environmentally benign gas that does not react with other chemicals and does not burn. Infinia’s improvements to the Stirling cycle system will enable the cost-effective mass production of high-efficiency air conditioners that use no polluting refrigerants.

None

2010-09-01T23:59:59.000Z

32

YMGI Through-the-Wall Air Conditioner Determined Noncompliant...  

Energy Savers [EERE]

air conditioner is one solution to cooling part of a house. | Photo courtesy of iStockphotoLUke1138. Ductless Mini-Split Air Conditioners Ductless, Mini-Split Heat Pumps...

33

The effects of galvanic corrosion on air conditioner performance  

E-Print Network [OSTI]

Corrosion of air conditioner outdoor heat exchangers (condensers) poses a significant problem for consumers living in coastal regions. This research sought to experimentally determine effects of galvanic corrosion on air conditioner condenser coils...

Grisham, Phillip Ryan

2001-01-01T23:59:59.000Z

34

Covered Product Category: Room Air Conditioners  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance across a variety of product categories, including room air conditioners, which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

35

Covered Product Category: Residential Central Air Conditioners  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance across a variety of product categories, including residential central air conditioners (CACs), which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

36

EECBG Direct Equipment Purchase Air Conditioner Guide Equipment Type  

E-Print Network [OSTI]

EECBG Direct Equipment Purchase Air Conditioner Guide Equipment Type Size Category (Btu/h) Size.ahridirectory.org/ceedirectory/pages/ac/cee/defaultSearch.aspx 12,000 Btu/h = 1 ton Less than 65,000 Btu/h Air Conditioners, Air Cooled Air Conditioners, Water completed by the California Energy Commission at a rate of 12,000 Btu/h per ton of air conditioning Source

37

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

E-Print Network [OSTI]

for Refrigerators and Air Conditioners in India. Michael A.followed by room air conditioners. Both of these appliancesfrost-free units. Room air conditioners in India have

McNeil, Michael A.

2010-01-01T23:59:59.000Z

38

Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges  

E-Print Network [OSTI]

Efficiency of Room Air Conditioners in India: OpportunitiesStar Labeled room Air Conditioners. ” Ministry of Power (of Superefficient Room Air Conditioners,” Lawrence Berkeley

Phadke, Amol

2014-01-01T23:59:59.000Z

39

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network [OSTI]

Standard Levels for Room Air Conditioners Michael A. McNeilFigure 1 – MEPS for 1.5 ton Window Air Conditioners – 1994-4 Figure 2 – Air Conditioner Test Data and Rating Plan -

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

40

Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype  

SciTech Connect (OSTI)

This report documents the design of a desiccant enhanced evaporative air conditioner (DEVAP AC) prototype and the testing to prove its performance. Previous numerical modeling and building energy simulations indicate a DEVAP AC can save significant energy compared to a conventional vapor compression AC (Kozubal et al. 2011). The purposes of this research were to build DEVAP prototypes, test them to validate the numerical model, and identify potential commercialization barriers.

Kozubal, E.; Woods, J.; Judkoff, R.

2012-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

2015-02-12 Issuance: Test Procedures for Portable Air Conditioners...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Test Procedures for Portable Air Conditioners; Notice of Proposed Rulemaking 2015-02-12 Issuance: Test Procedures for Portable Air Conditioners; Notice of Proposed Rulemaking...

42

Assessment of Environmentally Friendly Refrigerants for Window Air Conditioners  

SciTech Connect (OSTI)

This paper presents technical assessment of environmentally friendly refrigerants for window air conditioners that currently use refrigerant R410A for residential and commercial applications. The alternative refrigerants that are studied for its replacement include R32, R600a, R290, R1234yf, R1234ze and a mixture of R32 (90% molar concentration) and R125 (10% molar concentration). Baseline experiments were performed on a window unit charged with R410A. The ORNL Heat Pump Design Model was calibrated with the baseline data and was used to assess the comparative performance of the WAC with alternative refrigerants. The paper discusses the advantages and disadvantages of each refrigerants and their suitability for window air conditioners.

Bansal, Pradeep [ORNL] [ORNL; Shen, Bo [ORNL] [ORNL

2014-01-01T23:59:59.000Z

43

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner...  

Broader source: Energy.gov (indexed) [DOE]

Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards DOE Orders AeroSys to Halt Distribution of...

44

E-Print Network 3.0 - air conditioners electronic Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AND NEXT GENERATION Summary: ... xvi Adsorption Heat Pumps and Air Conditioners ... xvi Absorption Chillers......

45

E-Print Network 3.0 - air conditioner screening Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AND NEXT GENERATION Summary: ... xvi Adsorption Heat Pumps and Air Conditioners ... xvi Absorption Chillers......

46

E-Print Network 3.0 - adsorption air conditioner Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AND NEXT GENERATION Summary: ... xvi Adsorption Heat Pumps and Air Conditioners ... xvi Absorption Chillers......

47

Commercial Central Air Conditioners, Purchasing Specifications for Energy-Efficient Products (Fact Sheet)  

SciTech Connect (OSTI)

Energy efficiency purchasing specifications for federal procurements of commercial central air conditioners.

Not Available

2011-02-01T23:59:59.000Z

48

Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners  

E-Print Network [OSTI]

replacement options have and are being developed. Choice of Refrigerant: The most efficient air conditioners

Shah, Nihar

2014-01-01T23:59:59.000Z

49

DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS  

E-Print Network [OSTI]

AIR CONDITIONERS AND HEAT PUMPS K. Dao, M. Wahlig, E. Wali,are liquid paths. DM: multistage pump driver, driven by highvapor. DW: main circulation pump driven by strong absorbent.

Dao, K.

2013-01-01T23:59:59.000Z

50

Analysis on the energy efficiency of variable-frequency air conditioners (Hitachi models as an example) Jim Jr-Min Lin 2014.09.26  

E-Print Network [OSTI]

Analysis on the energy efficiency of variable-frequency air conditioners (Hitachi models (Max) Energy Efficiency @min load Energy Efficiency @Max load kW kW kW kW W/W W/W RAS-22NB 1.00 3.20 0 Efficiency @min load Energy Efficiency @Max load kW kW kW kW W/W W/W RAM-5FNS(B) - 12.5 - 2.91 - 4.3 RAM-6FNS

51

Residential Air Conditioner Direct Load Control "Energy Partners Program"  

E-Print Network [OSTI]

RESIDENTIAL AIR CONDITIONER DIRECT LOAD CONTROL "ENERGY PARTNERS PROGRAMn John D. Cook Supervisor Houston ABSTRACT Demand side management programs like Energy Partners can provide an effective peak reducing capability which within a.... In this partnership the customer allows HLfP to install a I switch on his/her air conditioner or heat pump and i periodically cycle the unit off during the hottest summer 1 days. In return the customer benefits by receiving an incentive payment, as well...

Cook, J. D.

1994-01-01T23:59:59.000Z

52

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

E-Print Network [OSTI]

Central Air Conditioners and Heat Pumps Energy ConservationCentral Air Conditioners and Heat Pumps. Washington DC:Central Air Conditioners and Heat Pumps Energy Conservation

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-01-01T23:59:59.000Z

53

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

E-Print Network [OSTI]

Products: Central Air Conditioners and Heat Pumps EnergyResidential Central Air Conditioners and Heat Pumps.Products: Central Air Conditioners and Heat Pumps Energy

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-01-01T23:59:59.000Z

54

Engineering computer models for refrigerators, freezers, furnaces, water heaters, room and central air conditioners  

SciTech Connect (OSTI)

This User's Guide provides the necessary information for understanding and using a computer model developed for the US Department of Energy which predicts the performance (energy consumption) of household refrigerators, refrigerator-freezers, and freezers. The model is capable of simulating various cabinet configurations (top-mount, bottom-mount, side-by-side, single-door) and refrigeration unit combinations (back-mounted static condenser with single forced convection evaporator, hot wall condenser with cooled wall panels, etc.). The program is comprised of two main subroutines: a cabinet heat-load submodel and a refrigeration unit submodel; they can be used separately for preliminary design analysis or together for performance evaluations. A technical description of the model and information on how to structure input parameters are provided. The user is provided with specific guidance for running the model on a computer. Specific instructions are given in the Appendices for changing and running the model using the operating language compatible with the DOE computer terminal system. Other users will have to modify the procedures in these sections as necessary for different computers.

Not Available

1982-11-01T23:59:59.000Z

55

Assessing the Impact of Measurement Policy on the Accuracy of Certified Energy Efficiency Ratio for Split-System Air Conditioners  

E-Print Network [OSTI]

of Unitary Air Conditioners and Heat Pumps, ASHRAE, 1791of Unitary Air Conditioner and Heat Pump Simulation Modelsfor Rating Unitary Air-Conditioning and Heat Pump Equipment,

Yu, Bingyi

2013-01-01T23:59:59.000Z

56

Installation of Window Air Conditioners Page 1 of 2 Virginia Polytechnic Institute and State University No. 5705 Rev.: 3  

E-Print Network [OSTI]

Installation of Window Air Conditioners Page 1 of 2 Virginia Polytechnic Institute and State __________________________________________________________________________________ Subject: Installation of Window Air Conditioners........................................................................................................................................1 1. Purpose To define a policy for installation of window air conditioners that avoids exterior

Buehrer, R. Michael

57

Influence of Air Conditioner Operation on Electricity Use and Peak Demand  

E-Print Network [OSTI]

Electricity demand due to occupant controlled room air conditioners in a large mater-metered apartment building is analyzed. Hourly data on the electric demand of the building and of individual air conditioners are used in analyses of annual...

McGarity, A. E.; Feuermann, D.; Kempton, W.; Norford, L. K.

1987-01-01T23:59:59.000Z

58

Air Conditioner User Behavior in a Master-Metered Apartment Building  

E-Print Network [OSTI]

Air conditioner operation was studied in order to understand how energy consumption and peak power are determined by user behavior, equipment operation and building characteristics. In a multi-family building, thirteen room air conditioners were...

Kempton, W.; Feuermann, D.; McGarity, A. E.

1987-01-01T23:59:59.000Z

59

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

check in the air conditioning products category is indicatednumber of domestic air conditioning product manufacturers100 million worth of air conditioner products to 14 major

Zhou, Nan

2010-01-01T23:59:59.000Z

60

STATE OF CALIFORNIA CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS  

E-Print Network [OSTI]

STATE OF CALIFORNIA CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS CEC Volume Single Zone Unitary Air Conditioner and Heat Pump Systems (Page 1 of 4) Project Name CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS CEC-MECH-3A (Revised 08

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Room Air Conditioners | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to: navigation, searchVirginia BlueRiverwoods,RockRipple,Rollingwood, Texas:Conditioners Jump

62

Laboratory Performance Testing of Residential Window Air Conditioners  

SciTech Connect (OSTI)

Window air conditioners are the dominant cooling product for residences, in terms of annual unit sales. They are inexpensive, portable and can be installed by the owner. For this reason, they are an attractive solution for supplemental cooling, for retrofitting air conditioning into a home which lacks ductwork, and for renters. Window air conditioners for sale in the United States are required to meet very modest minimum efficiency standards. Four window air conditioners' performance were tested in the Advanced HVAC Systems Laboratory on NREL's campus in Golden, CO. In order to separate and study the refrigerant system's performance, the unit's internal leakage pathways, the unit's fanforced ventilation, and the leakage around the unit resulting from installation in a window, a series of tests were devised that focused on each aspect of the unit's performance. These tests were designed to develop a detailed performance map to determine whole-house performance in different climates. Even though the test regimen deviated thoroughly from the industry-standard ratings test, the results permit simple calculation of an estimated rating for both capacity and efficiency that would result from a standard ratings test. Using this calculation method, it was found that the three new air conditioners' measured performance was consistent with their ratings. This method also permits calculation of equivalent SEER for the test articles. Performance datasets were developed across a broad range of indoor and outdoor operating conditions, and used them to generate performance maps.

Winkler, J.; Booten, C.; Christensen, D.; Tomerlin, J.

2013-03-01T23:59:59.000Z

63

Development of vehicle magnetic air conditioner (VMAC) technology. Final report  

SciTech Connect (OSTI)

The objective of Phase I was to explore the feasibility of the development of a new solid state refrigeration technology - magnetic refrigeration - in order to reduce power consumption of a vehicle air conditioner by 30%. The feasibility study was performed at Iowa State University (ISU) together with Astronautics Corporation of America Technology Center (ACATC), Madison, WI, through a subcontract with ISU.

Gschneidner, Karl A., Jr.; Pecharsky, V.K.; Jiles, David; Zimm, Carl B.

2001-08-28T23:59:59.000Z

64

Monitoring and evaluation of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached houses in Austin, Texas  

SciTech Connect (OSTI)

The US DOE initiated this project to evaluate the performance of an air conditioner retrofit program in Austin, Texas. The City's Austin's Resource Management Department pursued this project to quantify the retrofit effect of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached homes. If successfully implemented, this retrofit program could help defer construction of a new power plant which is a major goal of this department. The project compares data collected from 12 houses during two cooling seasons under pre-retrofit and then post-retrofit air conditioner units. The existing low-efficiency air conditioners were monitored during the 1987 cooling season, replaced during the 1987--88 heating season with new, smaller sized, high-efficiency units, and then monitored again during the 1988 cooling season. Results indicated that the air conditioner retrofits reduce the annual air conditioner electric consumption and peak electric demand by an average of 38%. When normalized to the nominal capacity of the air conditioner, average demand savings were 1.12 W/ft{sup 2} and estimated annual energy savings were 1.419 kWh/ft{sup 2}. Individual air conditioner power requirements were found to be a well defined function of outdoor temperature as expected. In the absence of detailed data, estimates of the peak demand reductions of new air conditioners can be made from the manufacturer's specifications. Air conditioner energy consumption proved to be strongly linear as a function of the outdoor temperature as expected when taken as an aggregate. No noticeable differences in the diversity factor of the air conditioner usage were found. Analysis of the retrofit effect using PRISM yields estimates of the reduction in normalized annual consumption (NAC) and annual cooling consumption of 12% and 30%. 2 refs., 11 figs., 17 tabs.

Burns, R.; Hough, R.E. (Fleming (W.S.) and Associates, Inc., Syracuse, NY (United States))

1991-10-01T23:59:59.000Z

65

Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates  

E-Print Network [OSTI]

An experimental study was conducted to quantify the effect of return air leakage from hot/humid attic spaces on the performance of a residential air conditioner. Tests were conducted in psychrometric facilities where temperatures and humidities...

O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

1996-01-01T23:59:59.000Z

66

Central Air conditioners | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160Benin:Energy Information on PV EconomicsOregon:Centereach,conditioners Jump to:

67

Determining benefits and costs of improved central air conditioner efficiencies  

SciTech Connect (OSTI)

Economic impacts on individual consumers from possible revisions to U.S. residential-type central air conditioner energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a central air conditioner and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers due to modest increases in efficiency are significant. For an efficiency increase of 20percent over the existing minimum standard (i.e., 12 SEER), 35percent of households with central air conditioners experience significant LCC savings, with an average savings of $453, while 25percent show significant LCC losses, with an average loss of $158 compared to apre-standard LCC average of $5,170. The remainder of the population (40percent) are largely unaffected.

Rosenquist, G.; Levok, A.; Chan, P.; McMahon, J.

2001-01-12T23:59:59.000Z

68

The Impact of Energy Recovery on Window Air-conditioner Efficiency  

E-Print Network [OSTI]

An experimental energy recovering air-conditioner can produce fresh air exchange heat with exhaust air in the heat exchanger, which has no additional moving parts. The EER of the experimental air-conditioner (EAC) is increased by 17.4~37.3 percent...

Luo, Q.; Tang, C.; Liao, K.

2006-01-01T23:59:59.000Z

69

Development of empirical temperature and humidity-based degraded-condition indicators for low-tonnage air conditioners  

E-Print Network [OSTI]

A split-system direct-expansion air conditioner was used to empirically determine temperature and return-air humidity indicators that could detect performance degradation resulting from degraded conditions. The air conditioner test bench...

Watt, James Bonner

1997-01-01T23:59:59.000Z

70

E-Print Network 3.0 - absorption air conditioner Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rating Summary: size systems such as absorption or vapor compression air-conditioners or heat pumps, the following... degradation. There are two possible designs for adjusting the...

71

E-Print Network 3.0 - air conditioners energy Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

energy optimization tool to analyze Summary: --when an existing component (e.g., an air conditioner) fails, it must be replaced by a more efficient component (e... National...

72

Measured Impacts of Air Conditioner Condenser Shading  

E-Print Network [OSTI]

reaching the expansion valve. In theory, the efficiency of vapor compression air conditioning can be improved through two primary mechanisms associated with condenser shading: Direct shading. Incident solar radiation can pose approximately a 1,000 w...]: IEYPERAlURL COUPARlSOn A/C SHADING DP. 1 (Some): SOUR RADlAllON COUPARISON I=AYEI[Nl KYP orq=82.1 , mu=87.(22 Z=CONDEHSIR ARU AIR lEYP orq=83.8 , mox=02.858 TIME OF DAY, (hr) 9 12 15 TIME OF DAY, (hr) Figure 3. Sample daily 15-minute data for June 21...

Parker, D. S.; Barkaszi, S. F.; Sonne, J. K.

1996-01-01T23:59:59.000Z

73

Common Air Conditioner Problems | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehicles » AlternativeUp HomeHorse Backwards | DepartmentCommon Air

74

Maintaining Your Air Conditioner | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehicles »Exchange Visitorsfor Shade LandscapingMaintaining Your Air

75

Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications: Preprint  

SciTech Connect (OSTI)

A novel liquid-desiccant air conditioner that dries and cools building supply air will transform the use of direct-contact liquid-desiccant systems in HVAC applications, improving comfort, air quality, and providing energy-efficient humidity control.

Lowenstein, A.; Slayzak, S.; Kozubal, E.

2006-07-01T23:59:59.000Z

76

Central Air Conditioner Enforcement Policy Statement | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energyon ArmedWaste andAccessCO2 Injection Begins inCarmineCentral Air Conditioner

77

Problem Type Problem Type Description Air Conditioning Air conditioner not working, leaking, etc  

E-Print Network [OSTI]

Problem Type Problem Type Description Air Conditioning Air conditioner not working, leaking, etc, Microfridges Doors and Hardware Door repair/replace Lock, latch or hinge repair, key stuck; Lost or stolen key, repair or replace Shades/Blinds Window treatment - repair or replace Washer/Dryer Washer/Dryer repair

Tennessee, University of

78

Techno-Economic Analysis of Indian Draft Standard Levels for RoomAir Conditioners  

SciTech Connect (OSTI)

The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency. In support of BEE's refrigerator program, Lawrence Berkeley National Laboratory (LBNL) produced an analysis of national impacts of standards in collaboration with the Collaborative Labeling and Standards Program (CLASP). That analysis drew on LBNL's experience with standards programs in the United States, as well as many other countries. Subsequently, as part of the process for setting optimal levels for air conditioner regulations, CLASP commissioned LBNL to provide support to BEE in the form of a techno-economic evaluation of air conditioner efficiency technologies. This report describes the methodology and results of this techno-economic evaluation. The analysis consists of three components: (1) Cost effectiveness to consumers of efficiency technologies relative to current baseline. (2) Impacts on the current market from efficiency regulations. (3) National energy and financial impacts. The analysis relied on detailed and up-to-date technical data made available by BEE and industry representatives. Technical parameters were used in conjunction with knowledge about air conditioner use patterns in the residential and commercial sectors, and prevailing marginal electricity prices, in order to give an estimate of per-unit financial impacts. In addition, the overall impact of the program was evaluated by combining unit savings with market forecasts in order to yield national impacts. LBNL presented preliminary results of these analyses in May 2006, at a meeting of BEEs Technical Committee for Air Conditioners. This meeting was attended by a wide array of stakeholder, including industry representatives, engineers and consumer advocates. Comments made by stakeholders at this meeting are incorporated into the final analysis presented in this report. The current analysis begins with the Rating Plan drafted by BEE in 2006, along with an evaluation of the market baseline according to test data submitted by manufacturers. MEPS, label rating levels, and baseline efficiencies are presented in Section 2. First, we compare Indian MEPS with current standards in other countries, and assess their relative stringency. Baseline efficiencies are then used to estimate the fraction of models likely to remain on the market at each phase of the program, and the impact on market-weighted efficiency levels. Section 3 deals with cost-effectiveness of higher efficiency design options. The cost-benefit analysis is grounded in technical parameters provided by industry representatives in India. This data allows for an assessment of financial costs and benefits to consumers as a result of the standards and labeling program. A Life-Cycle Cost (LCC) calculation is used to evaluate the impacts of the program at the unit level, thus providing some insight into the appropriateness of the levels chosen, and additional opportunities for further ratcheting. In addition to LCC, we also calculate payback periods, cost of conserved energy (CCE), and return on investment (ROI). Finally, Section 4 covers national impacts. This is an extension of unit level estimates in the two previous sections. Extrapolation to the national level depends on a forecast of air conditioner purchases (shipments), which we describe here. Following the cost-benefit analysis, we construct several efficiency scenarios including the BEE plan, but also considering further potential for efficiency improvement. These are combined with shipments through a stock accounting model in order to forecast air conditioner energy consumption in each sc

McNeil, Michael A.; Iyer, Maithili

2007-03-01T23:59:59.000Z

79

An Evaluation of Steady-State Dehumidification Characteristics of Residential Central Air Conditioners, Final Report  

E-Print Network [OSTI]

Conditioners, Air Source HeatPumps, and Sound-Rated Outdoor Unitary Equipment that ARI publishes twice a yearCl], In addition to the ARI certification, many manufacturerspublish detailed performance (capacity, efficiency, and dehumidification) data....2 - Performance and hardware data collectedfor this survey. 3.2 References 1. "Directory of Certified Unitary Air Conditioners, Air Source HeatPumps, and Sound-Rated Outdoor Unitary Equipment", Semi-Annual Issues, Air Conditioning and Refrigeration Institute...

O'Neal, D. L.; Chan, N.; Somasundaram, S.; Katipamula, S.

1987-01-01T23:59:59.000Z

80

E-Print Network 3.0 - air conditioners water Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Moving the Market toward High Efficiency Summary: and water source air conditioners and heat pumps <135,000 Btuh and for large commercial packaged water... h and <135,000 Btuh...

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

A Preliminary Evaluation of Alternative Liquid Desiccants for a Hybrid Desiccant Air Conditioner  

E-Print Network [OSTI]

and the condenser of a vapor-compression air conditioner. The liquid desiccants studied were lithium chloride, lithium bromide, calcium chloride, and triethylene glycol. Each candidate desiccant was subjected to a screening process which weighed the merits...

Studak, J. W.; Peterson, J. L.

1988-01-01T23:59:59.000Z

82

E-Print Network 3.0 - automobile air conditioners Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Search Powered by Explorit Topic List Advanced Search Sample search results for: automobile air conditioners Page: << < 1 2 3 4 5 > >> 1 7-55E An office that is being cooled...

83

The Impact of Residential Air Conditioner Charging and Sizing on Peak Electrical Demand  

E-Print Network [OSTI]

of laboratory tests of a three-ton, capillary tube expansion, split-system air conditioner, system capacity and efficiency data available from manufacturer's literature, and assumptions about relative sizing of the equipment to cooling load on a residence. A...

Neal, L.; O'Neal, D. L.

84

Truman STaTe univerSiTyWELCOME HOME! Air Conditioner  

E-Print Network [OSTI]

air conditioner requests.If you need air conditioning and are assigned to Centennial,Grim,or Fair,Missouri Hall,Ryle Hall and West Campus Suites have air conditioning included).The documentation must that requires the need for air conditioning. Please fill out the form on the reverse side of this sheet, attach

Gering, Jon C.

85

Energy Impacts of Oversized Residential Air Conditioners -- Simulation Study of Retrofit Sequence Impacts  

SciTech Connect (OSTI)

This research addresses the question of what are the energy consequences for oversizing of an air conditioner in a home. Conventional wisdom holds that oversizing the AC results in significant energy penalties. However, the reason for this was shown to be due to crankcase heaters and not due to cycling performance of the AC, and is only valid for a particular set of assumptions. Adding or removing individual characteristics, such as ducts or crankcase heaters, can have measurable impacts on energy use. However, with all other home characteristics held constant, oversizing the AC generally has a small effect on cooling energy use, even if the cycling performance of the unit is poor. The relevant aspects of air conditioner modeling are discussed to illustrate the effects of the cycling loss coefficient, Cd, capacity, climate, ducts and parasitic losses such as crankcase heaters. A case study of a typical 1960's vintage home demonstrates results in the context of whole building simulations using EnergyPlus.

Booten, C.; Christensen, C.; Winkler, J.

2014-11-01T23:59:59.000Z

86

Swozzle based burner tube premixer including inlet air conditioner for low emissions combustion  

DOE Patents [OSTI]

A burner for use in a combustion system of a heavy-duty industrial gas turbine includes a fuel/air premixer having an air inlet, a fuel inlet, and an annular mixing passage. The fuel/air premixer mixes fuel and air into a uniform mixture for injection into a combustor reaction zone. The burner also includes an inlet flow conditioner disposed at the air inlet of the fuel/air premixer for controlling a radial and circumferential distribution of incoming air. The pattern of perforations in the inlet flow conditioner is designed such that a uniform air flow distribution is produced at the swirler inlet annulus in both the radial and circumference directions. The premixer includes a swozzle assembly having a series of preferably air foil shaped turning vanes that impart swirl to the airflow entering via the inlet flow conditioner. Each air foil contains internal fuel flow passages that introduce natural gas fuel into the air stream via fuel metering holes that pass through the walls of the air foil shaped turning vanes. By injecting fuel in this manner, an aerodynamically clean flow field is maintained throughout the premixer. By injecting fuel via two separate passages, the fuel/air mixture strength distribution can be controlled in the radial direction to obtain optimum radial concentration profiles for control of emissions, lean blow outs, and combustion driven dynamic pressure activity as machine and combustor load are varied.

Tuthill, Richard Sterling (Bolton, CT); Bechtel, II, William Theodore (Scotia, NY); Benoit, Jeffrey Arthur (Scotia, NY); Black, Stephen Hugh (Duanesburg, NY); Bland, Robert James (Clifton Park, NY); DeLeonardo, Guy Wayne (Scotia, NY); Meyer, Stefan Martin (Troy, NY); Taura, Joseph Charles (Clifton Park, NY); Battaglioli, John Luigi (Glenville, NY)

2002-01-01T23:59:59.000Z

87

Effect of refrigerant charge, duct leakage, and evaporator air flow on the high temerature performance of air conditioners and heat pumps.  

E-Print Network [OSTI]

??An experimental study was conducted to quantify the effect of several installation items on the high outdoor ambient temperature performance of air conditioners. These installation… (more)

Rodriguez, Angel Gerardo

2012-01-01T23:59:59.000Z

88

Technical and economic analysis of energy efficiency of Chinese room air conditioners  

SciTech Connect (OSTI)

China has experienced tremendous growth in the production and sales of room air conditioners over the last decade. Although minimum room air conditioner energy efficiency standards have been in effect since 1989, no efforts were made during most of the 1990's to update the standard to be more reflective of current market conditions. In 1999, China's State Bureau of Technical Supervision (SBTS) included in their annual plan the development and revision of the 1989 room air conditioner standard, and experts from SBTS worked together with LBNL to analyze the new standards. Based on the engineering and life cycle-cost analyses performed, the most predominant type of room air conditioner in the Chinese market (split-type with a cooling capacity between 2500 and 4500 W (8500 Btu/h and 15,300Btu/h)) can have its efficiency increased cost-effectively to an energy efficiency ratio (EER) of 2.92 W/W (9.9 Btu/hr/W). If an EER standard of 2.92 W/W became effective in 2001, Chinese consumers would be estimated to save over 3.5 billion Yuan (420 million U.S. dollars) over the period of 2001-2020. Carbon emissions over the same period would be reduced by approximately 12 million metric tonnes.

Fridley, David G.; Rosenquist, Gregory; Jiang, Lin; Li, Aixian; Xin, Dingguo; Cheng, Jianhong

2001-02-01T23:59:59.000Z

89

Air Conditioner Efficiency Under Hot Dry and Hot Humid Conditions - The Utility Perspective  

E-Print Network [OSTI]

Air Conditioner Efficiency under Hot Dry and Hot Humid Conditions - The Utility Perspective Ammi Amarnath Technical Leader, Energy Efficiency & Demand Response Program Electric Power Research Institute 3420 Hillview Avenue Palo Alto, CA... are summarized below. Recommendations ? Establish a utility and energy efficiency agency coordinating council for regional standards; ? Identify regional centers to provide the institutional support; ? Develop recommended best practices for regionally based...

Amarnath, A.

90

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network [OSTI]

Air Conditioner Testing in WECC,” IEEE Power  Engineering Air Conditioner Modeling, WECC Load Modeling Task  Force in power system studies: WECC progress update,? Power and 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

91

7-55E An office that is being cooled adequately by a 12,000 Btu/h window air-conditioner is converted to a computer room. The number of additional air-conditioners that need to be installed is to be determined.  

E-Print Network [OSTI]

7-20 7-55E An office that is being cooled adequately by a 12,000 Btu/h window air-conditioner is converted to a computer room. The number of additional air-conditioners that need to be installed/h. Then noting that each available air conditioner provides 4,000 Btu/h cooling, the number of air- conditioners

Bahrami, Majid

92

The Influence of Operating Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner  

E-Print Network [OSTI]

A field investigation was carried out in an office building of Changsha city in winter and summer, the influence of different running modes, curtain styles and room temperature set point on energy consumption of room air conditioner (RAC...

Yu, J.; Yang, C.; Guo, R.; Wu, D.; Chen, H.

2006-01-01T23:59:59.000Z

93

Energy Consumption Estimation for Room Air-conditioners Using Room Temperature Simulation with One-Minute Intervals  

E-Print Network [OSTI]

For the purpose of developing optimized control algorithm for room air-conditioners to ensure their energy efficiency, a short time interval (i.e., one minute) simulation of building thermal performance is necessary because the sampling time...

Wang, F.; Yoshida, H.; Matsumoto, K.

2006-01-01T23:59:59.000Z

94

Simulation of Dehumidification Characteristics of High Efficiency Residential Central Air-Conditioners in Hot and Humid Climates  

E-Print Network [OSTI]

This study assesses the dehumidifying performance of the high efficiency residential central air conditioners (CAC) in hot/humid climates typified by that of Houston and Galveston. The performance study is based on such factors as: (i) weather (ii...

Katipamula, S.; O'Neal, D.; Somasundram, S.

1988-01-01T23:59:59.000Z

95

Effects of system cycling, evaporator airflow, and condenser coil fouling on the performance of residential split-system air conditioners  

E-Print Network [OSTI]

EFFECTS OF SYSTEM CYCLING, EVAPORATOR AIRFLOW, AND CONDENSER COIL FOULING ON THE PERFORMANCE OF RESIDENTIAL SPLIT-SYSTEM AIR CONDITIONERS A Thesis by JEFFREY BRANDON DOOLEY Submitted to the Office of Graduate Studies... COIL FOULING ON THE PERFORMANCE OF RESIDENTIAL SPLIT-SYSTEM AIR CONDITIONERS A Thesis by JEFFREY BRANDON DOOLEY Submitted to Texas A&M University in partial fulfillment of the requirements for the degree of MASTER...

Dooley, Jeffrey Brandon

2005-02-17T23:59:59.000Z

96

STRATEGIC PLAN TO REDUCE THE ENERGY IMPACT OF AIR CONDITIONERS  

E-Print Network [OSTI]

Acknowledgements This report represents the efforts of many experts from the air conditioning industry who Manufacturer Freus Air Conditioning Jim Bazemore Consultant Energy Market Innovations, Inc. Doug Beaman of Heating and Air Conditioning Industries Kahn Air Conditioning Tav Commins Staff, Buildings

97

13 SEER Standard for Central Air Conditioners and Heat Pumps (released in AEO2005)  

Reports and Publications (EIA)

In January 2004, after years of litigation in a case that pitted environmental groups and Attorneys General from 10 states against the U.S. Secretary of Energy, the U.S. Court of Appeals for the Second Circuit reestablished the central air conditioner and heat pump standard originally set in January 200. The Courts ruling, which struck down a May 2002 rollback of the 2001 standard to a 12 Seasonal Energy Efficiency Ratio (SEER) mandates that all new central air conditioners and heat pumps meet a 13 SEER standard by January 2006, requiring a 30% increase in efficiency relative to current law. The Annual Energy Outlook 2005 reference case incorporates the 13 SEER standard as mandated by the Courts ruling.

2005-01-01T23:59:59.000Z

98

Cromer Cycle Air Conditioner: A Study to Confirm Target Performance  

E-Print Network [OSTI]

The Cromer cycle uses a desiccant wheel operating in conjunction with a typical air conditioning system. Simulations and laboratory prototypes demonstrate that the cycle has the potential for enhanced humidity control with sensible heat ratios...

Cromer, C. J.

2001-01-01T23:59:59.000Z

99

Effect of refrigerant charge, duct leakage, and evaporator air flow on the high temerature performance of air conditioners and heat pumps  

E-Print Network [OSTI]

An experimental study was conducted to quantify the effect of several installation items on the high outdoor ambient temperature performance of air conditioners. These installation items were: improper amount of refrigerant charge, reduced...

Rodriguez, Angel Gerardo

2012-06-07T23:59:59.000Z

100

Desiccant Moisture Exchange for Dehumidification Enhancement of Air Conditioners  

E-Print Network [OSTI]

* -led use of this inprarrPd air mtianer cycle with dssicrants will met likely occur in the cammrcial sector bbm desiccants are acmnonly IaKWn end the potential for savimy is greatar. Cne patential amnercial a~plication where the humidity pmblm...

Cromer, C. J.

1988-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Measure Guideline: Air Conditioner Diagnostics, Maintenance, and Replacement  

SciTech Connect (OSTI)

This guideline responds to the need for an efficient means of identifying, diagnosing, and repairing faults in air conditioning systems in existing homes that are undergoing energy upgrades. Inadequate airflow due to constricted ducts or undersized filters, improper refrigerant charge, and other system defects can be corrected at a fraction of the cost of equipment replacement and can yield significant savings. The guideline presents a two-step approach to diagnostics and repair.

Springer, D.; Dakin, B.

2013-03-01T23:59:59.000Z

102

NREL Solves Residential Window Air Conditioner Performance Limitations (Fact Sheet)  

SciTech Connect (OSTI)

Comprehensive performance tests lead to enhanced modeling capability and affordable methods to increase energy efficiency.

Not Available

2013-05-01T23:59:59.000Z

103

Covered Product Category: Room Air Conditioners | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top FiveDepartmentfor EngineeringDepartment| Department of EnergyRoom Air

104

2014-05-05 Issuance: Test Procedure for Portable Air Conditioners; Notice of Data Availability  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register notice of data availabilty regarding test procedures for portable air conditioners, as issued by the Deputy Assistant Secretary for Energy Efficiency on May 5, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

105

Cromer Cycle Air Conditioner: A Unique Air-Conditioner Desiccant Cycle to Enhance Dehumidification and Save Energy  

E-Print Network [OSTI]

-Enhanced Cooling and Dehumidification System," ASBRAE Transactions 1994, V.100, Pt. 2, #3816, American Society of Heating, Refrigeration and Air Conditioning Engineers, Atlanta, GA, 1994 [7] Chant, E. E., Transient and Stearj, State Simulations of an Advanced..., the Electric Power Research Institute (EPRI) estimate from their surveys that 30% of their customers use dehumidifiers. [1] In supermarkets, where much of the sensible cooling is already done by the display cases, wasteful overcooling is done...

Cromer, C. J.

2000-01-01T23:59:59.000Z

106

Conservation Division regiulations for appliance-efficiency standards relating to refrigerators and freezers, room air conditioners, central air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances  

SciTech Connect (OSTI)

The text of the appliance efficiency standards for certain types of new appliances sold in California is presented. Specifications and test methods to identify complying refrigerators, freezers, air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances are covered.

Not Available

1981-12-16T23:59:59.000Z

107

Energy savings and economics of advanced control strategies for packaged air conditioners with gas heat  

SciTech Connect (OSTI)

This paper presents an evaluation of the potential energy savings from adding advanced control to existing packaged air conditioners. Advanced control options include air-side economizer, multi-speed fan control, demand control ventilation and staged cooling. The energy and cost savings from the different control strategies individually and in combination are estimated using the EnergyPlus detailed energy simulation program for four building types, namely, a small office building, a stand-alone retail building, a strip mall building and a supermarket building. For each of the four building types, the simulation was run for 16 locations covering all 15 climate zones in the U.S. The maximum installed cost of a replacement controller that provides acceptable payback periods to owners is estimated.

Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

2013-10-01T23:59:59.000Z

108

EA-1892: Direct Final Rule Energy Conservation Standards for Residential Furnaces and Residential Central Air Conditioners & Heat Pumps  

Broader source: Energy.gov [DOE]

This EA evaluates the environmental impacts of a proposal to adopt energy conservation standards for various consumer products and certain commercial and industrial equipment, including residential furnaces and residential air conditioners and heat pumps, as required by the Energy Policy and Conservation Act, as amended (42 U.S.C. 6291 et seq.)

109

Development of minimum efficiency standards for large capacity air conditioners, and commercial water heaters, refrigerators, and freezers. Final report  

SciTech Connect (OSTI)

The California Energy Resources Conservation and Development Commission has promulgated appliance energy efficiency standards and energy conservation standards for new construction with the objective of reducing energy consumption in the State of California. The following appliance categories are specifically addressed: large capacity air conditioners; commercial water heaters; and commercial refrigerators and freezers. The tasks that have been performed include: an energy use pattern study for the subject equipment; an examination of the size distribution of commercial air conditioning equipment; an examination of the different types of commercial air conditioning systems; an evaluation of the effectiveness of economizers in reducing commercial air conditioning system energy consumption in California; an examination of the effects of oversizing commercial air conditioners; a detailed study of supermarket refrigeration and air conditioning equipment; an evaluation of the economic feasibility of utilizing air conditioner waste heat to heat water; an assessment of the applicability of existing test procedures for small water heaters to large water heaters; and a brief investigation of the marketing and distribution systems for air conditioning and refrigeration equipment. Results of the efforts are described.

Merrill, P.S.; Rettberg, R.J.; Erickson, R.C.; Toor, J.S.

1980-05-01T23:59:59.000Z

110

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

SciTech Connect (OSTI)

This report describes an analysis of the economic impacts of possible energy efficiency standards for commercial unitary air conditioners and heat pumps on individual customers in terms of two metrics: life-cycle cost (LCC) and payback period (PBP). For each of the two equipment classes considered, the 11.5 EER provides the largest mean LCC savings. The results show how the savings vary among customers facing different electricity prices and other conditions. At 11.5 EER, at least 80% of the users achieve a positive LCC savings. At 12.0 EER, the maximum efficiency analyzed, mean LCC savings are lower but still positive. For the {ge} $65,000 Btu/h to <135,000 Btu/h equipment class, 59% of users achieve a positive LCC savings. For the $135,000 Btu/h to <240,000 Btu/h equipment class, 91% of users achieve a positive LCC savings.

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-03-31T23:59:59.000Z

111

Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners  

E-Print Network [OSTI]

of energy storage and water heater all year round”, Energyof thermal energy storage and water heaters to ensure theair conditioner, water heater and energy storage device is

Shah, Nihar

2014-01-01T23:59:59.000Z

112

2014-03-06 Issuance: Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps; Notice of Proposed Rulemaking  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register notice of proposed rulemaking regarding test procedures for packaged terminal air conditioners and packaged terminal heat pumps, as issued by the Deputy Assistant Secretary on March 6, 2014.

113

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

E-Print Network [OSTI]

Central Air Conditioners and Heat Pumps Energy ConservationW.R. Coleman. 1990. “Heat Pump Life and Compressor LongevityC.C.. 1990. “Predicting Future Heat Pump Production Volume

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-01-01T23:59:59.000Z

114

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

SciTech Connect (OSTI)

In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER.

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-10-10T23:59:59.000Z

115

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

SciTech Connect (OSTI)

The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptive frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.

McNeil, Michael A.; Iyer, Maithili

2009-05-30T23:59:59.000Z

116

An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with a Thermal Expansion Valve  

E-Print Network [OSTI]

by the manufacturer for a specific indoor and outdoor temperatures. Once the full charge was determined, the unit was subjected to 40%, 30%, 20%, 15%, 10%, and 5% undercharging and 5%, 10%, 15%, and 20% overcharging of refrigerant by mass. The fully charged tests were... CONDITION All tests were performed on a split system central air conditioner provided by the Trane company. To determine the proper amount of refrigerant charge needed in the system and the unit's corresponding performance, charging specifications...

Farzad, M.; O'Neal, D. L.

1989-01-01T23:59:59.000Z

117

Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study  

SciTech Connect (OSTI)

The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The performance degradation of R410A at higher temperatures was greater than R22. However, the R22 and R410A systems both operated normally during all tests. Visual observations of the R410A system provided no indication of vibrations or TXV hunting at high ambient outdoor test conditions with the compressor operating in the transcritical regime.

Piotr A. Domanski; W. Vance Payne

2002-10-31T23:59:59.000Z

118

Evaluation of a CFD-model for simulation of simplified flow conditioners  

SciTech Connect (OSTI)

Perforated plate flow conditioners are used to generate a fully developed turbulent flow profile upstream of an orifice meter. It is very time-consuming to measure the effect of a flow conditioner for different upstream flow profiles. Therefore a project is initiated to evaluate the performance of a computational fluid computer code for this purpose. If the code correctly predicts the flow characteristics downstream of more complex flow conditioners. In this study a k-{var_epsilon} CFD-model was used to predict the flow downstream of obstruction plates having one large or nine small holes. Both mean velocity, turbulent kinetic energy, k, and the dissipation rate of turbulent kinetic energy, {var_epsilon}, were calculated and compared against measured data. The results indicate that it is possible to predict the mean velocity well and that the accuracy of the predicted k and {var_epsilon} depends on the complexity of the flow.

Erdal, A. [Statoil/K-LAB, Haugesund (Norway); Torbergsen, L.E.; Rimestad, S.; Krogstad, P.A. [Norwegian Inst. of Technology, Trondheim (Norway)

1995-12-31T23:59:59.000Z

119

Performance characteristics of a turbo expander substituted for expansion valve on air-conditioner  

SciTech Connect (OSTI)

An experimental study is conducted on a small turbo expander which could be applied to the expansion process in place of expansion valves in refrigerator or air-conditioner to improve the cycle efficiency by recovering energy from the throttling process. The operating gas is HFC134a and the maximum cooling capacity of experiment apparatus is 32.7 kW. Four different turbo expanders are tested to find the performance characteristics of the turbo expander when they operate at a low partial admission rate. The partial admission rate is 1.70% or 2.37, and expanders are operated in the supersonic flow. In the experiment, pressure and temperature are measured at 10 different locations in the experimental apparatus. In addition to these measurements, output power at the turbo expander is measured through a generator installed on a rotor shaft with the rotational speed. Performance data of the turbo expander are obtained at many part load operations by adjusting the output power of the generator. A maximum of 15.8% total-to-static efficiency is obtained when the pressure ratio and the partial admission ratio are 2.37 and 1.70%, respectively. Experimental results show that the optimal velocity ratio decreases when the pressure ratio is decreased, and peak efficiencies, which are obtained at locally maximized efficiency depending on the operating condition, vary linearly against the subcooling temperature or the pressure ratio. (author)

Cho, Soo-Yong [Department of Mechanical and Aerospace Engineering (ReCAPT), Gyeongsang National University, 900 Gajoa-dong, Jinju 660-701 (Korea); Cho, Chong-Hyun [School of Mechanical and Aerospace Engineering, Gyeongsang National University, 900 Gajoa-dong, Jinju 660-701 (Korea); Kim, Chaesil [Department of Mechanical Engineering, Changwon National University, 9 Sarim-dong, Changwon 641-773 (Korea)

2008-09-15T23:59:59.000Z

120

Are You Planning to Bring an Air Conditioner? Welcome to Truman State University and the services available through the Disability Services Office. Part of  

E-Print Network [OSTI]

conditioner requests. If you need air conditioning and are assigned to Centennial, Grim, or Fair Apartments, Missouri Hall, Ryle Hall, and West Campus Suites have air conditioning included). The documentation must that requires the need for air conditioning. Please fill out the form on the reverse side of this sheet, attach

Gering, Jon C.

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

E-Print Network 3.0 - air-conditioners furnaces air Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Residential Space Summary: and electricity. These include boilers and furnaces for heating, air-conditioning systems and heat-pump systems... ) Space Heating Only Furnaces:...

122

The Effect of Reduced Evaporator Air Flow on the Performance of a Residential Central Air Conditioner  

E-Print Network [OSTI]

This paper discusses the measured degradation in performance of a residential air conditioning system operating under reduced evaporator air flow. Experiments were conducted using a R-22 three-ton split-type cooling system with a short-tube orifice...

Palani, M.; O'Neal, D.; Haberl, J.

123

DOE Takes Action to Stop the Sales of Air-Con Air Conditioner...  

Energy Savers [EERE]

12CO09EV12EV. Today's notice proposes the maximum penalty for selling non-compliant products and requires Air-Con to immediately cease further U.S. sales and provide written...

124

An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with Capillary Tube Expansion  

E-Print Network [OSTI]

of the coil was 20.94 ft2 with refrigerant tube sizes of 3/8". The outdoor fan was located on the top of the outdoor coil. The fan specifications are given in Table 3.1. Figure 3.3 - Detail of Outdoor Test Section 25 Table 3.1 - Fan Specification...ESL-TR-88/07-01 AN EVALUATION OF IMPROPER REFRIGERANT CHARGE ON THE PERFORMANCE OF A SPLIT SYSTEM AIR CONDITIONER WITH CAPILLARY TUBE EXPANSION FINAL REPORT Submitted by Mohsen Farzad Dennis L. O'Neal Prepared For ENERGY SYSTEMS LABORATORY RESEARCH...

Farzad, M.; O'Neal, D. L.

1988-01-01T23:59:59.000Z

125

Experimental analysis of a window air conditioner with a R-22 and R32/R125/R134a mixture  

SciTech Connect (OSTI)

Much experimental and theoretical analysis of potential R-22 replacements has been accomplished. However, published information about the experimental analysis of any off-the-shelf air conditioner with a potential R-22 replacement at realistic, operating conditions is still rare. This type of work could be useful because it provides baseline data for comparing the performance of R-22 and its potential replacement at drop-in conditions. In this study, an off-the-shelf window air conditioner was tested at Air Conditioning and Refrigeration Institute (ARI)-rated indoor conditions and at different ambient temperatures, including the ARI-rated outdoor condition, with R-22 and with its potential replacement, a ternary mixture of R-32(30%)/R-125(10%)/R-134a(60%) (the ternary mixture). A test rig was built that provided for baseline operation and for the option of operating the system with a flooded evaporator by means of liquid over-feeding (LOF). The test results indicated the cooling capacity of the ternary mixture was 7.7% less than that of R-22 at 95{degrees}F ambient for baseline operation. The cooling capacity for both refrigerants improved when a flooded evaporator, or LOF, was used. For LOF operation, the cooling capacity of the ternary mixture was only 1.1% less than that of R-22. The ternary mixture had slightly higher compressor discharge pressure, a lower compressor discharge temperature, slightly lower compressor power consumption, and a higher compressor high/low pressure ratio.

Mei, V.C.; Chen, F.C.; Chen, D.T. [Oak Ridge National Lab., TN (United States); HuangFu, E.P. [USDOE, Washington, DC (United States)

1995-07-01T23:59:59.000Z

126

Monitoring the Performance of a Residential Central Air Conditioner under Degraded Conditions on a Test Bench  

E-Print Network [OSTI]

enthalpies at six locations were calculated using the refrigerant property calculation program developed by Kartsounes[26]. Air-side enthalpy, humidity and specific volume were calculated by a psychrometric program developed at the Energy Systems Laboratory... procedure based on measurement of refrigerant and air side temperatures. n TABLE OF CONTENTS CHAPTER Page I INTRODUCTION 1 E LITERATURE REVIEW 3 Service and failure patterns 3 Degradation studies 4 HI MODEL DEVELOPMENT 6 Theory of operation 6 Degraded...

Palani, M.; O'Neal, D. L.; Haberl, J. S.

1992-01-01T23:59:59.000Z

127

The Explorationon the Energy Saving Potential of an Innovative Dual-temperature Air Conditioner and the Mechanism of the Theoretical Mixed Refrigeration Cycl  

E-Print Network [OSTI]

The Exploration on the Energy Saving Potential of an Innovative Dual-temperature Air Conditioner and the Mechanism of the Theoretical Mixed Refrigeration Cycle Zhao Lei, Zhao Xijin, Hu Andu Professor, graduate student, graduate student...-temperature air conditioning system and its corresponding theoretical mixed refrigeration cycle are proposed. This consists of a separate air handling unit and a metal radiation panel as the dual-temperature evaporators, a compressor, a condenser, two thermal...

Zhao,L.; Zhao,X.; Hu,A.

2014-01-01T23:59:59.000Z

128

Dirty Air Conditioners: Energy Implications of Coil Fouling Jeffrey Siegel, Lawrence Berkeley National Laboratory/ UC Berkeley  

E-Print Network [OSTI]

. For typical residential heat pump and air conditioning Residential Buildings: Technologies, Design heat pump condenser coil will foul sufficiently to cause a 20 % reduction in performance over a 4 to 7 is based on a model of heat exchanger fouling that we developed specifically for residential heat

Siegel, Jeffrey

129

Dirty Air Conditioners: Energy Implications of Coil Fouling Jeffrey Siegel, Lawrence Berkeley National Laboratory/ UC Berkeley  

E-Print Network [OSTI]

. For typical residential heat pump and air conditioning #12;systems, they predict a 10 ­ 25 % average energy heat pump condenser coil will foul sufficiently to cause a 20 % reduction in performance over a 4 to 7 is based on a model of heat exchanger fouling that we developed specifically for residential heat

130

E-Print Network 3.0 - ac line conditioners Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AND NEXT GENERATION Summary: ... xvi Adsorption Heat Pumps and Air Conditioners ... xvi Absorption Chillers......

131

E-Print Network 3.0 - array power conditioner Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AND NEXT GENERATION Summary: ... xvi Adsorption Heat Pumps and Air Conditioners ... xvi Absorption Chillers......

132

Applying a Domestic Water-cooled Air-conditioner in Subtropical Cities  

E-Print Network [OSTI]

Water-cooled air-conditioning systems (WACS) are in general more energy efficient than air-cooled air-conditioning systems (AACS), especially in subtropical climates where the outdoor air is hot and humid. Related studies focused on evaluating...

Lee, W.; Chen, H.

2006-01-01T23:59:59.000Z

133

Improving Best Air Conditioner Efficiency by 20-30% through a High Efficiency Fan and Diffuser Stage Coupled with an Evaporative Condenser Pre-Cooler  

SciTech Connect (OSTI)

The Florida Solar Energy Center (FSEC) conducted a research project to improve the best residential air conditioner condenser technology currently available on the market by retrofitting a commercially-available unit with both a high efficiency fan system and an evaporative pre-cooler. The objective was to integrate these two concepts to achieve an ultra-efficient residential air conditioner design. The project produced a working prototype that was 30% more efficient compared to the best currently-available technologies; the peak the energy efficiency ratio (EER) was improved by 41%. Efficiency at the Air-Conditioning and Refrigeration Institute (ARI) standard B-condition which is used to estimate seasonal energy efficiency ratio (SEER), was raised from a nominal 21 Btu/Wh to 32 Btu/Wh.

Parker, Danny S; Sherwin, John R; Raustad, Richard

2014-04-10T23:59:59.000Z

134

Cornell's (LSC) project began providing 16,000 tons of cooling (1 ton of cooling = 12,000 Btu/hr, or approximately one large residential window air conditioner) to Cornell University's Ithaca  

E-Print Network [OSTI]

window air conditioner) to Cornell University's Ithaca campus in July of 2000. This project has almost completely replaced mechanical refrigeration for the Cornell district cooling system with the following benefits: · Greater LSC has replaced

Keinan, Alon

135

E-Print Network 3.0 - air conditioner utilizing Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

51 National Renewable Energy Laboratory (NREL) researchers enhanced this building energy optimization tool to analyze Summary: --when an existing component (e.g., an air...

136

An Investigation of Alternative Methods for Measuring Static Pressure of Unitary Air Conditioners and Heat Pumps  

E-Print Network [OSTI]

This project was created to address an important issue currently faced by test facilities measuring static pressure for air-conditioning and heat pumps. Specifically, ASHRAE Standard 37, the industry standard for test setup, requires an outlet duct...

Wheeler, Grant Benson

2013-08-12T23:59:59.000Z

137

Fault detection methods for vapor-compression air conditioners using electrical measurements  

E-Print Network [OSTI]

(cont.) This method was experimentally tested and validated on a commercially available air handler and duct system. In the second class of faults studied, liquid refrigerant, rather than vapor, enters the cylinder of a ...

Laughman, Christopher Reed.

2008-01-01T23:59:59.000Z

138

Investigations on Vapour Compression Air Conditioner with Direct Contact Desiccant Loop over Condenser and Evaporator  

E-Print Network [OSTI]

Perceived air quality increases when relative humidity is decreased till about 30% in the range of comfort temperature. In the present scenario, humidity is considered as a pollutant. Hence, a controlled environment not only at low temperature...

Maiya, M. P.; Ravi, J.; Tiwari, S.

2010-01-01T23:59:59.000Z

139

Testing and Economic Evaluation of a High Efficiency 10-ton Rooftop Air Conditioner  

E-Print Network [OSTI]

In 1993, the U.S. Environmental Protection Agency initiated a project to design, build and demonstrate a high efficiency commercial rooftop air conditioning unit. The unit was designed by Hibberd Consulting of Westminster, Colorado, and was built...

O'Neal, D. L.; Davis, M. A.

2006-11-09T23:59:59.000Z

140

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network [OSTI]

9   1.2.1.   Air Conditioner Testing and 16   2.0   Air Conditioner Results of Residential Air Conditioner Testing in WECC,” 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Improving the Operating Efficiency of Packaged Air Conditioners and Heat Pumps  

SciTech Connect (OSTI)

This article discusses several control strategies that can significantly reduce energy consumption associated with packaged rooftop units RTUs). Although all of the considered strategies are widely used in built-up air-handing units, they are not commonly used in existing RTUs. Both simulation and field evaluations show that adding these control strategies to existing RTUs can reduce their energy consumption by between 30% and 60%.

Katipamula, Srinivas; Wang, Weimin; Vowles, Mira

2014-03-10T23:59:59.000Z

142

2015-02-12 Issuance: Test Procedures for Portable Air Conditioners; Notice  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustionImprovement3 Beryllium-Associated Worker2014 HouseCoveredAirDepartment ofof04of Proposed

143

Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners  

E-Print Network [OSTI]

its integration. In the DOE’s energy model which was used toSources The energy efficiency simulation model used in thiss Bottom Up Energy Analysis System (BUENAS) model (McNeil et

Shah, Nihar

2014-01-01T23:59:59.000Z

144

Modeling diffusion of electrical appliances in the residential sector  

E-Print Network [OSTI]

Error Distribution - Air Conditioners Error Distribution -televisions, and air conditioners 5 . The task of modelingfrom UNDESA. 2.1.3. Air Conditioner Climate Variable

McNeil, Michael A.

2010-01-01T23:59:59.000Z

145

2015-02-13 Issuance: Energy Conservation Standards for Portable Air Conditioners; Notice of Public Meeting and Availability of the Preliminary Technical Support Document  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register notice of public meeting regarding energy conservation standards for portable air conditioners, as issued by the Deputy Assistant Secretary for Energy Efficiency on February 13, 2015. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

146

A Novel, Low-Cost, Reduced-Sensor Approach for Providing Smart Renote Monitoring and Diagnostics for Packaged Air Conditioners and Heat Pumps  

SciTech Connect (OSTI)

This report describes conceptually an approach to providing automated remote performance and conditioning monitoring and fault detection for air conditioners and heat pumps that shows great promise to reduce the capital and installation costs of such systems from over $1000 per unit to $200 to $400 per unit. The approach relies on non-intrusive electric load monitoring (NIELM) to enable separation of the power use signals of compressors and fans in the air conditioner or heat pump. Then combining information on the power uses and one or two air temperature measurements, changes in energy efficiency and occurrence of major faults would be detected. By decreasing the number of sensors used from between ten and twenty in current diagnostic monitoring systems to three for the envisaged system, the capital cost of the monitoring system hardware and the cost of labor for installation would be decreased significantly. After describing the problem being addressed and the concept for performance monitoring and fault detection in more detail, the report identifies specific conditions and faults that the proposed method would detect, discusses specific needs for successful use of the NIELM approach, and identifies the major elements in the path from concept to a commercialized monitoring and diagnostic system.

Brambley, Michael R.

2009-09-01T23:59:59.000Z

147

An Analysis of Efficiency Improvements in Residential Sized Heat Pumps and Central Air Conditioners  

E-Print Network [OSTI]

LABORATORY NBS NATIONAL BUREAU OF STANDARDS NECPA NATIONAL ENERGY CONSERVATION POLICY ACT OEM ORIGINAL EQUIPMENT MANUFACTURERS ORNL OAK RIDGE NATIONAL LABORATORY PLF PART LOAD FACTOR SAI SCIENCE APPLICATION INCORPORATED SEER SEASONAL ENERGY EFFICIENCY RATIO... of variable speed units is discussed. The methodology includes: (1) making multiple runs of the Oak Ridge National Laboratory (ORNL) steady-state heat pump model, (2) making reasonable assumptions on the degradation factors, and (3) using a draft version...

O'Neal, D. L.; Boecker, C. L.; Penson, S. B.

1986-01-01T23:59:59.000Z

148

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomenthe HouseStudents2.2at MultipleorderNuclearThis fact sheetHeat Pump Models Shown

149

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network [OSTI]

2009.   Inverter  Test Procedures Solar Generation Impact Conditioner Testing Procedures  Appendix B: Air Conditioner air conditioner testing procedures and results from studies 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

150

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology  

SciTech Connect (OSTI)

The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

Not Available

1993-11-01T23:59:59.000Z

151

Solar-Powered, Liquid-Desiccant Air Conditioner for Low-Electricity Humidity Control: Report and Summary Report  

SciTech Connect (OSTI)

The primary objective of this project was to demonstrate the capabilities of a new high-performance, liquid-desiccant dedicated outdoor air system (DOAS) to enhance cooling efficiency and comfort in humid climates while substantially reducing electric peak demand at Tyndall Air Force Base (AFB), which is 12 miles east of Panama City, Florida.

Dean, J.; Kozubal, E.; Herrmann, L.; Miller, J.; Lowenstein, A.; Barker, G.; Slayzak, S.

2012-11-01T23:59:59.000Z

152

DOE Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomentheATLANTA, GA - U.S. Department ofThe U.S.D.C. - Energy Secretary WASHINGTON,to

153

Proceedings of Healthy Buildings 2009 Paper 474 Impacts of HVAC Filtration on Air-Conditioner Energy Consumption in  

E-Print Network [OSTI]

Proceedings of Healthy Buildings 2009 Paper 474 Impacts of HVAC Filtration on Air efficiency filters (Points A, B, and C, respectively). #12;Proceedings of Healthy Buildings 2009 Paper 474

Siegel, Jeffrey

154

Applying Learnable Evolution Model to Heat Exchanger Design Kenneth A. Kaufman and Ryszard S. Michalski*  

E-Print Network [OSTI]

of the evaporator tubes in the heat exchanger of an air conditioner. This is a very difficult problem because conditioner, refrigerant flows through a loop. It is superheated and placed in contact with cooler outside air conditions, manufacturers of air conditioning systems currently assume in their models average operating

Michalski, Ryszard S.

155

Experimental analysis of a window air conditioner with R-22 and zeotropic mixture of R-32/125/134a  

SciTech Connect (OSTI)

This study is the result of the cooperative research and development agreement (CRADA) between Oak Ridge National Laboratory and E.I. Du Pont De Nemours and Company, Inc., (CRADA No. 92-0161) for testing the use of heat exchangers as the evaporator and condenser in an air-conditioning rig. Heat exchangers at typical realistic operating conditions were tested with R-22 and with its potential replacement, a ternary mixture of R-32(30%)/R-125(10%)/R-134a(60%). A test rig was built that provided for operation of the low-temperature exchanger (evaporator) with flooded coils. The test results indicated that the performance of the evaporator heat exchanger using ternary mixture, in terms of cooling capacity, would be around 7.4% less than the performance using R-22. The cooling capacity for both refrigerants improved with flooded evaporator operation by 8.6% for R-22 and by 15% for ternary mixture. Compared with R-22 operation, operation with ternary mixture results in slightly higher compressor discharge pressure, lower compressor discharge temperature, slightly lower compressor power consumption, and a higher compressor high-low pressure ratio. Temperature glide for ternary mixture, for both evaporator and condenser, was clearly evident, but not as pronounced as expected because of the pressure drop (and thus the temperature drop) along the coils. Further improvement of the performance of ternary mixture is possible if the evaporator is arranged in a counter-cross-flow configuration to take advantage of the temperature glide. Current evaporator designs are mostly concurrent-cross-flow, which is more appropriate for single-component refrigerants or azeotropic refrigerant mixtures.

Mei, V.C.; Chen, F.C.; Carlstedt, J.; Hallden, D.

1995-08-01T23:59:59.000Z

156

13 EER Window Air Conditioner  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up from theDepartment( Sample of Shipment Notice)1021STATE ENERGY PROGRAM

157

E-Print Network 3.0 - air-cooled water chillers Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and centrifugal chillers... ... xvi Adsorption Heat Pumps and Air Conditioners ... xvi Absorption Chillers......

158

Future Air Conditioning Energy Consumption in Developing Countries and what can be done about it: The Potential of Efficiency in the Residential Sector  

E-Print Network [OSTI]

an air conditioner for the first time, or by replacements ofair conditioner lifetime. Each retirement generates another replacementreplacements. Step 1 is described in detail in the section called Forecasting Air Conditioner

McNeil, Michael A.; Letschert, Virginie E.

2008-01-01T23:59:59.000Z

159

Future Air Conditioning Energy Consumption in Developing Countries and what can be done about it: The Potential of Efficiency in the Residential Sector  

E-Print Network [OSTI]

an air conditioner for the first time, or by replacements ofair conditioner lifetime. Each retirement generates another replacementand replacements. Step 1 is described in detail in the section called Forecasting Air Conditioner

McNeil, Michael A.; Letschert, Virginie E.

2008-01-01T23:59:59.000Z

160

Attenuator And Conditioner  

DOE Patents [OSTI]

An apparatus and method of attenuating and/or conditioning optical energy for an optical transmitter, receiver or transceiver module is disclosed. An apparatus for attenuating the optical output of an optoelectronic connector including: a mounting surface; an array of optoelectronic devices having at least a first end; an array of optical elements having at least a first end; the first end of the array of optical elements optically aligned with the first end of the array of optoelectronic devices; an optical path extending from the first end of the array of optoelectronic devices and ending at a second end of the array of optical elements; and an attenuator in the optical path for attenuating the optical energy emitted from the array of optoelectronic devices. Alternatively, a conditioner may be adapted in the optical path for conditioning the optical energy emitted from the array of optoelectronic devices.

Anderson, Gene R. (Albuquerque, NM); Armendariz, Marcelino G. (Albuquerque, NM); Carson, Richard F. (Albuquerque, NM); Bryan, Robert P. (Albuquerque, NM); Duckett, III, Edwin B. (Albuquerque, NM); Kemme, Shanalyn Adair (Albuquerque, NM); McCormick, Frederick B. (Albuquerque, NM); Peterson, David W. (Sandia Park, NM)

2006-04-04T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

INEEL AIR MODELING PROTOCOL ext  

SciTech Connect (OSTI)

Various laws stemming from the Clean Air Act of 1970 and the Clean Air Act amendments of 1990 require air emissions modeling. Modeling is used to ensure that air emissions from new projects and from modifications to existing facilities do not exceed certain standards. For radionuclides, any new airborne release must be modeled to show that downwind receptors do not receive exposures exceeding the dose limits and to determine the requirements for emissions monitoring. For criteria and toxic pollutants, emissions usually must first exceed threshold values before modeling of downwind concentrations is required. This document was prepared to provide guidance for performing environmental compliance-driven air modeling of emissions from Idaho National Engineering and Environmental Laboratory facilities. This document assumes that the user has experience in air modeling and dose and risk assessment. It is not intended to be a "cookbook," nor should all recommendations herein be construed as requirements. However, there are certain procedures that are required by law, and these are pointed out. It is also important to understand that air emissions modeling is a constantly evolving process. This document should, therefore, be reviewed periodically and revised as needed. The document is divided into two parts. Part A is the protocol for radiological assessments, and Part B is for nonradiological assessments. This document is an update of and supersedes document INEEL/INT-98-00236, Rev. 0, INEEL Air Modeling Protocol. This updated document incorporates changes in some of the rules, procedures, and air modeling codes that have occurred since the protocol was first published in 1998.

C. S. Staley; M. L. Abbott; P. D. Ritter

2004-12-01T23:59:59.000Z

162

Homeowner's Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet), Building America Case Study: Technology Solutions for Existing Homes, Building Technologies Office (BTO)  

SciTech Connect (OSTI)

This fact sheet offers a step-by-step guide to proper installation of window air conditioning units, in order to improve efficiency and comfort for homeowners.

Not Available

2013-06-01T23:59:59.000Z

163

A Generalized Battery Model of a Collection of Thermostatically Controlled Loads for Providing Ancillary Service  

E-Print Network [OSTI]

. Residential Thermostatically Controlled Loads (TCLs) such as air conditioner, heat pump, water heater, and re

Sanandaji, Borhan M.

164

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

E-Print Network [OSTI]

and energy usage characteristics for each of the 77 nationally representative buildings (determined from the computer modeling analysis) to actual modeled commercial

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-01-01T23:59:59.000Z

165

Development of slotted orifice flow conditioner  

E-Print Network [OSTI]

concentric rings of radial slots. The porosity of each ring varied so that the conditioner generated a six step parabolic profile similar to the profile tested with Fluent The overall porosity of the parabolic conditioner was 25. 1'/o, which is lower than... 19 Velocity Profile Procedure . Co Measurement Procedure Data Reduction . . . . . . 19 21 22 RESULTS 24 LDA Velocity Profile and Turbulence Intensity Analysis 24 Tube Bundle, Uniform Slotted Orifice Flow Conditioner . . Parabolic Slotted...

Ihfe, Larry Michael

1994-01-01T23:59:59.000Z

166

Analysis of Water Modeling of Air Entrainment  

E-Print Network [OSTI]

Analysis of Water Modeling of Air Entrainment S.C. Jain Professor and Research Engineer Dept. Civil, C., "Analysis of Water Modeling of Air Entrainment," in Proceedings of the 48th SFSA Technical An analysis is reported of the water modeling experiments of Bates et al. (1994) to study air entrainment

Beckermann, Christoph

167

Low-noise pulse conditioner  

DOE Patents [OSTI]

A low-noise pulse conditioner is provided for driving electronic digital processing circuitry directly from differentially induced input pulses. The circuit uses a unique differential-to-peak detector circuit to generate a dynamic reference signal proportional to the input peak voltage. The input pulses are compared with the reference signal in an input network which operates in full differential mode with only a passive input filter. This reduces the introduction of circuit-induced noise, or jitter, generated in ground referenced input elements normally used in pulse conditioning circuits, especially speed transducer processing circuits.

Bird, David A. (Oak Ridge, TN)

1983-01-01T23:59:59.000Z

168

EVALUATION OF A NEW SOLAR AIR CONDITIONER  

E-Print Network [OSTI]

· Benefits to California · Overall Technology Assessment · Appendices o Appendix A: Final Report (under-16 Grant Funding: $74,547 Term: February 2001 ­ June 2003 PIER Subject Area: Renewable Energy Technologies/Agricultural/Water End-Use Energy Efficiency · Renewable Energy Technologies · Environmentally-Preferred Advanced

169

Room Air Conditioners | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehicles »ExchangeDepartmentResolve to Save Energy This Year|Rooftop

170

Tips: Air Conditioners | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas ConchasPassiveSubmittedStatusButler Tina Butler Tina-Butler.jpg Tina L.

171

Room Air Conditioners | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartment of Energy fromCommentsRevolving Loan Funds Revolving LoanA l iSoftRTU Suite

172

DOE Investigates Possible Air Conditioner Efficiency Violations |  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana. DOCUMENTSof Energy DOE ChallengeThese(Notice of Proposed

173

ROOM AIR CONDITIONER WALL MOUNTED type  

E-Print Network [OSTI]

/ 150 (76 / 68) 238 / 207 (108 / 94) REFRIGERANT CHARGING PIPE LENGTH 25 ft. (7.5 m) 33 ft. (10 m) 49 ftY3E-A C O N T E N T S SPECIFICATIONS OUTLINE AND DIMENSIONS REFRIGERANT SYSTEM DIAGRAM CIRCUIT, Induction motor, Recipro CODE H25B18QABCA H25B18QABCA H25B24QABCA H25B24QABCA H25B35QABCA REFRIGERANT R-22

Kleinfeld, David

174

Future Air Conditioning Energy Consumption in Developing Countries and what can be done about it: The Potential of Efficiency in the Residential Sector  

E-Print Network [OSTI]

G. Henderson (2005) Home air conditioning in Europe – howhigher growth in Indian air conditioner saturation duringand A.A. Pavlova ( 2003). Air conditioning market saturation

McNeil, Michael A.; Letschert, Virginie E.

2008-01-01T23:59:59.000Z

175

Study of thermoelectric technology for automobile air conditioning  

SciTech Connect (OSTI)

An analytical study was conducted to determine the feasibility of employing thermoelectric (TE) cooling technology in automobile air conditioners. The study addressed two key issues -- power requirements and availability of thermoelectric materials. In this paper, a mathematical model was developed to predict the performance of TE air conditioners and to analyze power consumption. Results show that the power required to deliver a cooling capacity of 4 kW (13,80 Btu/h) in a 38{degree}C (100{degree}F) environment will be 9.5 kW electric. Current TE modules suitable for air conditioning are made of bismuth telluride. The element tellurium is expected to be in short supply if TE cooling is widely implemented for auto air conditioning; some options available in this regard were studied and presented in this paper.

Mathiprakasam, B.; Heenan, P. (Midwest Research Inst., Kansas City, MO (United States)); Mei, V.C.; Chen, F.C. (Oak Ridge National Lab., TN (United States))

1991-01-01T23:59:59.000Z

176

Air Tightness of US Homes: Model Development  

SciTech Connect (OSTI)

Air tightness is an important property of building envelopes. It is a key factor in determining infiltration and related wall-performance properties such as indoor air quality, maintainability and moisture balance. Air leakage in U.S. houses consumes roughly 1/3 of the HVAC energy but provides most of the ventilation used to control IAQ. The Lawrence Berkeley National Laboratory has been gathering residential air leakage data from many sources and now has a database of more than 100,000 raw measurements. This paper uses that database to develop a model for estimating air leakage as a function of climate, building age, floor area, building height, floor type, energy-efficiency and low-income designations. The model developed can be used to estimate the leakage distribution of populations of houses.

Sherman, Max H.

2006-05-01T23:59:59.000Z

177

Tips: Air Ducts | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

the walls, floors, and ceilings; it carries the air from your home's furnace and central air conditioner to each room. Ducts are made of sheet metal, fiberglass, or other...

178

air dispersion model: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

source apportionment studies. In highly polluted cities such as Athens, Los Angeles and Mexico, regional scale air quality models are used to forecast air pollution episodes ...

179

Optimization of Air Conditioning Cycling  

E-Print Network [OSTI]

on a 3-ton residential air conditioner are then presented to intuitively understand the effect of expansion valve and evaporator fan cycling in a real system. A real time optimization method is explored and the feasibility, recommendations for a...

Seshadri, Swarooph

2012-10-19T23:59:59.000Z

180

Math!. Comput. Modelling Vol. 23, No. 11/12, pp. 55-76. 1996 Copyright@1996 Elsevier Science Ltd  

E-Print Network [OSTI]

control system is the heating and cooling system of a typical home. The furnace and air conditioner, along and the thermostat's response is translated back to electrical currents which control the furnace, air conditioner that translate into commands to turn on or off the furnace or the air conditioner. This work was partially

Lemmon, Michael

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

2014-03-06 Issuance: Test Procedures for Packaged Terminal Air...  

Broader source: Energy.gov (indexed) [DOE]

Issuance: Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps; Notice of Proposed Rulemaking 2014-03-06 Issuance: Test Procedures for...

182

DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air...  

Broader source: Energy.gov (indexed) [DOE]

Minimum Appliance Standards DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards June 3, 2010 - 2:17pm Addthis...

183

PREV'AIR, a modeling platform for the air quality predictability study , C. Honor2  

E-Print Network [OSTI]

PREV'AIR, a modeling platform for the air quality predictability study Menut L.1 , C. Honoré2 , L Ministère de l'écologie et du développement durable, Paris, France This platform is proposed by the PREV'AIR about PREV'AIR ? please send an e-mail to cecile.honore@ineris.fr 1. Introduction Since 2002, the PREV'AIR

Menut, Laurent

184

air parcel model: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dynamics in the South Coast Air Basin of California. It has also been modified to model pollution in South Korea, Mexico Manohar, Rajit 30 Session 2: Modelling air pollution...

185

air pouch model: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dynamics in the South Coast Air Basin of California. It has also been modified to model pollution in South Korea, Mexico Manohar, Rajit 15 Session 2: Modelling air pollution...

186

VALMET-A valley air pollution model  

SciTech Connect (OSTI)

Following a thorough analysis of meteorological data obtained from deep valleys of western Colorado, a modular air-pollution model has been developed to simulate the transport and diffusion of pollutants released from an elevated point source in a well-defined mountain valley during the nighttime and morning transition periods. This initial version of the model, named VALMET, operates on a valley cross section at an arbitrary distance down-valley from a continuous point source. The model has been constructed to include parameterizations of the major physical processes that act to disperse pollution during these time periods. The model has not been fully evaluated. Further testing, evaluations, and development of the model are needed. Priorities for further development and testing are provided.

Whiteman, C.D.; Allwine, K.J.

1983-09-01T23:59:59.000Z

187

SIMULATION, MODELING AND ANALYSIS OF A WATER TO AIR  

E-Print Network [OSTI]

SIMULATION, MODELING AND ANALYSIS OF A WATER TO AIR HEAT PUMP By ARUN SHENOY Bachelor December, 2004 #12;SIMULATION, MODELING AND ANALYSIS OF A WATER TO AIR HEAT PUMP Thesis Approved................................................................3 2.1. Equation fit water to air heat pump and chiller models...............................3 2

188

Water Modeling of Steel Flow, Air Entrainment and Filtration  

E-Print Network [OSTI]

Water Modeling of Steel Flow, Air Entrainment and Filtration Christoph Beckermann Associate Beckermann, C., "Water Modeling of Steel Flow, Air Entrainment and Filtration," in Proceedings of the 46th, 1992. #12;Abstract This paper presents an analysis of water modeling of steel pouring to study (1) air

Beckermann, Christoph

189

Performance and Portability of an Air Quality Model Donald Dabdub  

E-Print Network [OSTI]

and planning for the control of air pollution episodes. The California Institute of Technology (CIT) photochemical model is one such air quality model. It is used to predict the pollution dynamics in the South Coast Air Basin of California. It has also been modified to model pollution in South Korea, Mexico

Manohar, Rajit

190

Session 2: Modelling air pollution across a range of scales  

E-Print Network [OSTI]

of Edinburgh BHF Centre for Cardiovascular Science Scottish Air Pollution and Health Workshop School;The health effects of air pollution The world-wide effects of air pollution are considerable MORTALITYSession 2: Modelling air pollution across a range of scales Ruth Doherty, Massimo Vieno, Ian Mac

191

Stochastic Microenvironment Models for Air Pollution Exposure  

E-Print Network [OSTI]

human exposure to air pollution." SIMS Technical Report No.human exposure to air pollution." Environment International.Annual Meeting of the A i r Pollution Control Association,

Naihua Duan

2011-01-01T23:59:59.000Z

192

Field Measurements of Efficiency and Duct Effectiveness in Residential Forced Air Distributions Systems  

E-Print Network [OSTI]

power for air conditioning, heat pumps and electricwith 13 air conditioners, eight heat pumps (one house hadPre Post * A C : air conditioning, HP : heat pump, GF : gas

Jump, D.A.

2011-01-01T23:59:59.000Z

193

Hierarchical Bayesian models for space-time air pollution data  

E-Print Network [OSTI]

Hierarchical Bayesian models for space-time air pollution data Sujit K. Sahu June 14, 2011 sets have led to a step change in the analysis of space-time air pollution data. Accurate predictions-time air pollution data and illustrate the benefits of modeling with a real data example on monitoring

Sahu, Sujit K

194

Distributed GIS for Monitoring and Modeling Urban Air Quality  

E-Print Network [OSTI]

The progress of technology has made the measurement of air quality and the simulation of complex air pollution models both feasible and cost-effective. However, there is a long way to go in terms of facilitating widespread ...

Yeang, Chen-Hsiang, 1969-

195

Assessing Uncertainty in Spatial Exposure Models for Air Pollution Health Effects Assessment  

E-Print Network [OSTI]

Holgate S. 2002. Air pollution and health. Lancet Brunekreef2006. Bayesian modeling of air pollution health effects withExposure Models for Air Pollution Health Effects Assessment

2007-01-01T23:59:59.000Z

196

Modeling impact of urban air pollution on health  

E-Print Network [OSTI]

Modeling impact of urban air pollution on health: Preliminary results and testing a methodology with hospitals for the study of air pollution impact on specific deceases (old people admitted in emergency morbidity data and pollutants concentrations at the regional/urban scale Health and air quality in France

Menut, Laurent

197

Atmospheric Modelling of Greenhouse Gases and Air Quality  

E-Print Network [OSTI]

. Increase in mixing height (h) entrains (draws in) air from above the box #12Atmospheric Modelling of Greenhouse Gases and Air Quality John C. Lin Courtenay Strong University of Utah: February 20th, 2013 Department of Atmospheric Sciences University of Utah #12;Outline ·CO2 ó Air

Tipple, Brett

198

air quality modeling: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dynamics in the South Coast Air Basin of California. It has also been modified to model pollution in South Korea, Mexico Manohar, Rajit 6 Reference Manual for Communication...

199

air quality modelling: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dynamics in the South Coast Air Basin of California. It has also been modified to model pollution in South Korea, Mexico Manohar, Rajit 6 Reference Manual for Communication...

200

air quality models: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dynamics in the South Coast Air Basin of California. It has also been modified to model pollution in South Korea, Mexico Manohar, Rajit 6 Reference Manual for Communication...

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

air quality model: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dynamics in the South Coast Air Basin of California. It has also been modified to model pollution in South Korea, Mexico Manohar, Rajit 6 Reference Manual for Communication...

202

A survey of air flow models for multizone structures  

SciTech Connect (OSTI)

Air flow models are used to simulate the rates of incoming and outgoing air flows for a building with known leakage under given weather and shielding conditions. Additional information about the flow paths and air-mass flows inside the building can only by using multizone air flow models. In order to obtain more information on multizone air flow models, a literature review was performed in 1984. A second literature review and a questionnaire survey performed in 1989, revealed the existence of 50 multizone air flow models, all developed since 1966, two of which are still under development. All these programs use similar flow equations for crack flow but differ in the versatility to describe the full range of flow phenomena and the algorithm provided for solving the set of nonlinear equations. This literature review was found that newer models are able to describe and simulate the ventilation systems and interrelation of mechanical and natural ventilation. 27 refs., 2 figs., 1 tab.

Feustel, H.E.; Dieris, J.

1991-03-01T23:59:59.000Z

203

VALMET: a valley air pollution model. Final report. Revision 1  

SciTech Connect (OSTI)

An air quality model is described for predicting air pollution concentrations in deep mountain valleys arising from nocturnal down-valley transport and diffusion of an elevated pollutant plume, and the fumigation of the plume on the valley floor and sidewalls after sunrise. Included is a technical description of the model, a discussion of the model's applications, the required model inputs, sample calculations and model outputs, and a full listing of the FORTRAN computer program. 55 refs., 27 figs., 6 tabs.

Whiteman, C.D.; Allwine, K.J.

1985-04-01T23:59:59.000Z

204

Future Air Conditioning Energy Consumption in Developing Countriesand what can be done about it: The Potential of Efficiency in theResidential Sector  

SciTech Connect (OSTI)

The dynamics of air conditioning are of particular interestto energy analysts, both because of the high energy consumption of thisproduct, but also its disproportionate impact on peak load. This paperaddresses the special role of this end use as a driver of residentialelectricity consumption in rapidly developing economies. Recent historyhas shown that air conditioner ownership can grow grows more rapidly thaneconomic growth in warm-climate countries. In 1990, less than a percentof urban Chinese households owned an air conditioner; by 2003 this numberrose to 62 percent. The evidence suggests a similar explosion of airconditioner use in many other countries is not far behind. Room airconditioner purchases in India are currently growing at 20 percent peryear, with about half of these purchases attributed to the residentialsector. This paper draws on two distinct methodological elements toassess future residential air conditioner 'business as usual' electricityconsumption by country/region and to consider specific alternative 'highefficiency' scenarios. The first component is an econometric ownershipand use model based on household income, climate and demographicparameters. The second combines ownership forecasts and stock accountingwith geographically specific efficiency scenarios within a uniqueanalysis framework (BUENAS) developed by LBNL. The efficiency scenariomodule considers current efficiency baselines, available technologies,and achievable timelines for development of market transformationprograms, such as minimum efficiency performance standards (MEPS) andlabeling programs. The result is a detailed set of consumption andemissions scenarios for residential air conditioning.

McNeil, Michael A.; Letschert, Virginie E.

2007-05-01T23:59:59.000Z

205

Modeling, Analysis, and Control of Demand Response Resources  

E-Print Network [OSTI]

Capacity Central AC Heat pumps Water heaters Refrigeratorsas air conditioners, heat pumps, electric water heaters, andMerced). ACs Heat Pumps Combined Water Heaters Refrigerators

Mathieu, Johanna L.

2013-01-01T23:59:59.000Z

206

Modeling, Analysis, and Control of Demand Response Resources  

E-Print Network [OSTI]

Capacity Central AC Heat pumps Water heaters Refrigeratorsas air conditioners, heat pumps, electric water heaters, andMerced). ACs Heat Pumps Combined Water Heaters Refrigerators

Mathieu, Johanna L.

2012-01-01T23:59:59.000Z

207

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network [OSTI]

Engineers, Inc. , Energy Efficient Design of New BuildingsStandard 90.1, Energy Efficient Design of New Buildings

Rosenquist, G.

2010-01-01T23:59:59.000Z

208

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network [OSTI]

of Energy-Energy Information Administration, A Look atof Energy-Energy Information Administration, 1995 Commercialof Energy-Energy Information Administration, Annual Energy

Rosenquist, G.

2010-01-01T23:59:59.000Z

209

Ductless Mini-Split Air Conditioners | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehicles » AlternativeUpDrain-Water Heat Recovery Drain-Water

210

Four Central Air Conditioners Determined Noncompliant With Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecordFederal7.pdfFlash_2010_-24.pdfOverviewPlansBuildings andEfficiency

211

Commercial Air Conditioners and Heat Pumps | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTieCelebrate Earth Codesthe Natural Resources Defenseon

212

List of Central Air conditioners Incentives | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth's Heat JumpInc Place:KeystoneSolar (Texas) JumpEventBoilersCeiling FanCentral

213

List of Room Air Conditioners Incentives | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth's Heat JumpInc Place:KeystoneSolarList ofPassive SolarRoofs Incentives Jump

214

High-Efficiency Window Air Conditioners - Building America Top Innovation |  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana.ProgramJulietip sheetK-4In 2013 many| Department HIGH

215

Variable Speed Fan Retrofits for Computer Room Air Conditioners |  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomen Owned SmallOf The 2012Nuclear Guide Remote55 Jefferson Ave. Valley ForgeValue

216

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network [OSTI]

Administration, Annual Energy Outlook 2000, December, 1999.trends from EIA's Annual Energy Outlook 2000 (AE02000) were

Rosenquist, G.

2010-01-01T23:59:59.000Z

217

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana.Program - LibbyofThisStatementNOTElectricity Transmissionof EnergyEnergy

218

Enforcement Policy Statement: Off Mode Standards for Central Air Conditioners  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana.Program -Department oftoTheseClickDepartment of Energy June

219

Product Standards for Air Conditioners (Japan) | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth'sOklahoma/GeothermalOrangePeru:JobInformation MccoyPrimusProEcoProcana

220

13-Energy Efficiency Ratio Window Air Conditioner | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top Five EERE Blog Posts of 2014 Year in Review:Summer-0 ResourcesEnergy

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Covered Product Category: Residential Central Air Conditioners | Department  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top FiveDepartmentfor EngineeringDepartment ofBoilersDataHotof Energy Central

222

Variable Speed Fan Retrofits for Computer Room Air Conditioners  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage »of EnergyTheTwoVulnerabilities | Department of|VTA,anCompression

223

HEATING, AIR-CONDITIONING AND REFRIGERATION DISTRIBUTORS INTERNATIONAL...  

Broader source: Energy.gov (indexed) [DOE]

of the updated Energy Conservation Standards for Air Conditioners, Furnaces and Heat Pumps. DOE EX Parte Memo.pdf More Documents & Publications 3rd Semi-Annual Report to...

224

air pollution model: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dynamics in the South Coast Air Basin of California. It has also been modified to model pollution in South Korea, Mexico Manohar, Rajit First Page Previous Page 1 2 3 4 5 6 7 8 9...

225

air pollution modelling: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dynamics in the South Coast Air Basin of California. It has also been modified to model pollution in South Korea, Mexico Manohar, Rajit First Page Previous Page 1 2 3 4 5 6 7 8 9...

226

air pollution modeling: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dynamics in the South Coast Air Basin of California. It has also been modified to model pollution in South Korea, Mexico Manohar, Rajit First Page Previous Page 1 2 3 4 5 6 7 8 9...

227

air pollution models: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dynamics in the South Coast Air Basin of California. It has also been modified to model pollution in South Korea, Mexico Manohar, Rajit First Page Previous Page 1 2 3 4 5 6 7 8 9...

228

Modelling the e#ects of air pollution on health using Bayesian Dynamic Generalised Linear Models  

E-Print Network [OSTI]

Modelling the e#ects of air pollution on health using Bayesian Dynamic Generalised Linear Models (2004)). Large multi­city studies such as `Air pollution and health: a European approach' (APHEA across a number of US and European cities. Short­term e#ects of air pollution on health are estimated

Bath, University of

229

Ontologies for the Integration of Air Quality Models and 3D City Models  

E-Print Network [OSTI]

-city densification may limit air pollution, carbon emissions, and energy use through reduced transportation of the most important environmental problems is air pollution, mostly induced by vehicle traffic1 Ontologies for the Integration of Air Quality Models and 3D City Models Claudine Metral Institut

Genève, Université de

230

Air Leakage of U.S. Homes: Model Prediction  

SciTech Connect (OSTI)

Air tightness is an important property of building envelopes. It is a key factor in determining infiltration and related wall-performance properties such as indoor air quality, maintainability and moisture balance. Air leakage in U.S. houses consumes roughly 1/3 of the HVAC energy but provides most of the ventilation used to control IAQ. The Lawrence Berkeley National Laboratory has been gathering residential air leakage data from many sources and now has a database of more than 100,000 raw measurements. This paper uses a model developed from that database in conjunction with US Census Bureau data for estimating air leakage as a function of location throughout the US.

Sherman, Max H.; McWilliams, Jennifer A.

2007-01-01T23:59:59.000Z

231

Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)  

SciTech Connect (OSTI)

This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

Kozubal, E.

2013-02-01T23:59:59.000Z

232

Modeling air entrainment in plunging jet using 3DYNAFS  

E-Print Network [OSTI]

As the liquid jet plunges into a free surface, significant air is entrained into the water and forms air pockets. These air pockets eventually break up into small bubbles, which travel downstream to form a bubbly wake. To better understand the underlying flow physics involved in the bubble entrainment, in the linked videos, air entrainment due to a water jet plunging onto a pool of stationary water was numerically studied by using the 3DYNAFS software suit. The flow field is simulated by directly solving the Navier-Stokes equations through the viscous module, 3DYNAFS-VIS, using a level set method for capturing the free surface. The breakup of entrained air pockets and the resulting bubbly flow were modeled by coupling 3DYNAFS-VIS with a Lagrangian multi-bubble tracking model, 3DYNAFS-DSM (Hsiao & Chahine, 2003), which emits bubbles into the liquid according to local liquid/gas interface flow conditions based on the sub-grid air entrainment modeling proposed by Ma et al. (2011), and tracks all bubbles in t...

Hsiao, Chao-Tsung; Wu, Xiongjun; Chahine, Georges L

2011-01-01T23:59:59.000Z

233

High Energy Efficiency Air Conditioning  

SciTech Connect (OSTI)

This project determined the performance of a new high efficiency refrigerant, Ikon B, in a residential air conditioner designed to use R-22. The refrigerant R-22, used in residential and small commercial air conditioners, is being phased out of production in developed countries beginning this year because of concerns regarding its ozone depletion potential. Although a replacement refrigerant, R-410A, is available, it operates at much higher pressure than R-22 and requires new equipment. R-22 air conditioners will continue to be in use for many years to come. Air conditioning is a large part of expensive summer peak power use in many parts of the U.S. Previous testing and computer simulations of Ikon B indicated that it would have 20 - 25% higher coefficient of performance (COP, the amount of cooling obtained per energy used) than R-22 in an air-cooled air conditioner. In this project, a typical new R-22 residential air conditioner was obtained, installed in a large environmental chamber, instrumented, and run both with its original charge of R-22 and then with Ikon B. In the environmental chamber, controlled temperature and humidity could be maintained to obtain repeatable and comparable energy use results. Tests with Ikon B included runs with and without a power controller, and an extended run for several months with subsequent analyses to check compatibility of Ikon B with the air conditioner materials and lubricant. Baseline energy use of the air conditioner with its original R-22 charge was measured at 90 deg F and 100 deg F. After changeover to Ikon B and a larger expansion orifice, energy use was measured at 90 deg F and 100 deg F. Ikon B proved to have about 19% higher COP at 90 deg F and about 26% higher COP at 100 deg F versus R-22. Ikon B had about 20% lower cooling capacity at 90 deg F and about 17% lower cooling capacity at 100 deg F versus R-22 in this system. All results over multiple runs were within 1% relative standard deviation (RSD). All of these values agree well with previous results and computer simulations of Ikon B performance versus R-22. The lower cooling capacity of Ikon B is not a concern unless a particular air conditioner is near its maximum cooling capacity in application. Typically, oversized A/C systems are installed by contractors to cover contingencies. In the extended run with Ikon B, which lasted about 4.5 months at 100 deg F ambient temperature and 68% compressor on time, the air conditioner performed well with no significant loss of energy efficiency. Post-run analysis of the refrigerant, compressor lubricant oil, compressor, compressor outlet tubing, and the filter/dryer showed minor effects but nothing that was considered significant. The project was very successful. All objectives were achieved, and the performance of Ikon B indicates that it can easily be retrofitted into R-22 air conditioners to give 15 - 20% energy savings and a 1 - 3 year payback of retrofit costs depending on location and use. Ikon B has the potential to be a successful commercial product.

Edward McCullough; Patrick Dhooge; Jonathan Nimitz

2003-12-31T23:59:59.000Z

234

Lessons learned in modeling Underfloor Air Distribution system  

E-Print Network [OSTI]

Underfloor Air Distribution (UFAD) Design Guide. Atlanta:for design cooling loads in underfloor air distribution (

Lee, Kwang Ho; Schiavon, Stefano; Webster, Tom; Bauman, Fred; Feng, Jingjuan; Hoyt, Tyler

2011-01-01T23:59:59.000Z

235

Impacts of Contaminant Storage on Indoor Air Quality: Model Development  

E-Print Network [OSTI]

. Impacts of contaminant storage on indoor air quality: Model development. Atmospheric Environment. LBNL the buffering of airborne chemical species by building materials and furnishings in the indoor environment to the time scale of depletion of the compound from the storage medium, however, the total exposure

236

Study of solar-assisted thermoelectric technology for automobile air conditioning  

SciTech Connect (OSTI)

An analytical study was conducted to determine the feasibility of employing solar energy assisted thermoelectric (TE) cooling technology in automobile air conditioners. The study addressed two key issues -- power requirements and availability of thermoelectric materials. In this paper a mathematical model was developed to predict the performance of TE air conditioners and to analyze power consumption. Results show that the power required to deliver a cooling capacity of 4 kW (13,680 Btu/h) in a 38 C (100 F) environment will be 9.5 kW electric. Current TE modules suitable for air conditioning are made of bismuth telluride. The element tellurium is expected to be in short supply if TE cooling is widely implemented for auto air conditioning; some options available in this regard were studied and presented in this paper. The photovoltaic (PV) cells, assumed to cover the roof area of a compact car can only generate about 225 W. However, this is more than enough to power a fan to provide air ventilation to the car interior which significantly reduces the peak cooling load when the car is parked in bright sunlight.

Mei, V.C.; Chen, F.C. [Oak Ridge National Lab., Oak Ridge, TN (United States); Mathiprakasam, B.; Heenan, P. [Midwest Research Inst., Kansas City, MO (United States)

1993-11-01T23:59:59.000Z

237

Impacts of contaminant storage on indoor air quality: Model development  

SciTech Connect (OSTI)

A first-order, lumped capacitance model is used to describe the buffering of airborne chemical species by building materials and furnishings in the indoor environment. The model is applied to describe the interaction between formaldehyde in building materials and the concentration of the species in the indoor air. Storage buffering can decrease the effect of ventilation on the indoor concentration, compared to the inverse dependence of indoor concentration on the air exchange rate that is consistent with a constant emission rate source. If the exposure time of an occupant is long relative to the time scale of depletion of the compound from the storage medium, however, the total exposure will depend inversely on the air exchange rate. This lumped capacitance model is also applied to moisture buffering in the indoor environment, which occurs over much shorter depletion timescales of the order of days. This model provides a framework to interpret the impact of storage buffering on time-varying concentrations of chemical species and resulting occupant exposure. Pseudo-steady state behavior is validated using field measurements. Model behavior over longer times is consistent with formaldehyde and moisture concentration measurements in previous studies.

Sherman, Max H.; Hult, Erin L.

2013-02-26T23:59:59.000Z

238

Magnetic Refrigeration Technology for High Efficiency Air Conditioning  

SciTech Connect (OSTI)

Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate heat exchangers or oil distribution issues found in traditional vapor compression systems.

Boeder, A; Zimm, C

2006-09-30T23:59:59.000Z

239

Spring is in the Air and so is a Plethora of Pollen Dr. Joan Bradshaw, County Extension Director  

E-Print Network [OSTI]

and skin. Use air filters and clean regularly, or run an air conditioner and change the air filterSpring is in the Air and so is a Plethora of Pollen Dr. Joan Bradshaw, County Extension Director, Suite 1 Lecanto, FL 34461 Springtime is in the air in Citrus County with its glorious weather

Jawitz, James W.

240

Framework for Coupling Room Air Models to Heat Balance Model Load and Energy Calculations (RP-1222)  

E-Print Network [OSTI]

1 Framework for Coupling Room Air Models to Heat Balance Model Load and Energy Calculations (RP in a program for hourly load calculations of a single thermal zone. The heat balance model for load and energy to heat balance model load and energy calculations," HVAC&R Research, 10(2), 91-111. #12;2 · Mixed

Chen, Qingyan "Yan"

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Model Reduction for Indoor-Air Behavior in Control Design for Energy-Efficient Buildings  

E-Print Network [OSTI]

Model Reduction for Indoor-Air Behavior in Control Design for Energy-Efficient Buildings Jeff models for the indoor-air environment in control design for energy efficient buildings. In one method by a desire to incorporate models of the indoor-air environment in the design of energy efficient buildings

Gugercin, Serkan

242

Bayesian latent variable modelling in studies of air pollution and health  

E-Print Network [OSTI]

Bayesian latent variable modelling in studies of air pollution and health Duncan Lee, Gavin://www.bath.ac.uk/math-sci/BICS #12;Bayesian latent variable modelling in studies of air pollution and health. Duncan Lee (1), Gavin to the approach adopted for modelling the trend and correlation. KEYWORDS: Air pollution and health; Bayesian

Burton, Geoffrey R.

243

20.18 Optimization Problems in Air Pollution Modeling Ivan Dimov, and Zahari Zlatev  

E-Print Network [OSTI]

20.18 Optimization Problems in Air Pollution Modeling Ivan Dimov, and Zahari Zlatev ABSTRACT. The appearance of optimization problems in the field of air pollution modeling and their importance arising in air pollution modeling will be considered. We shall present a review of some approaches

Dimov, Ivan

244

Creation of the model and implementation of the simulation of dispersion of air pollution in urban  

E-Print Network [OSTI]

Creation of the model and implementation of the simulation of dispersion of air pollution in urban..............................................................................................................1 1.2. Types of models of dispersion of air pollution was creation of the mathematical model and application of the simulation of dispersion of vehicular air

Bargiela, Andrzej

245

Parallelization of Air Quality Models on Structured Grids Using MPI  

E-Print Network [OSTI]

by the Clean Air Act in the United States. In order to understand air pollution and design e#11;ective control of the greatest concerns is air pollution. Air pollutants a#11;ect human health, the biosphere and damage property. Because of these e#11;ects air pollution is now monitored and regulated worldwide, for example

Sandu, Adrian

246

Lessons learned in modeling Underfloor Air Distribution system  

E-Print Network [OSTI]

terminal unit (TU) cooling design supply air temperature (due to the low supply airflow at low cooling load conditioncontrol the cooling air flow rate or reheated supply air to

Lee, Kwang Ho; Schiavon, Stefano; Webster, Tom; Bauman, Fred; Feng, Jingjuan; Hoyt, Tyler

2011-01-01T23:59:59.000Z

247

E-Print Network 3.0 - air flow models Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Institute of Aeronautics and Astronautics Numerical Modeling of Doorway Flow Summary: software. The problem that was modeled is that of a flow from an air curtain mounted...

248

Design, modelling and control of a gas turbine air compressor .  

E-Print Network [OSTI]

??The production of compressed air constitutes a considerable portion of industrial electrical consumption. An alternative to electrically driven air compression systems is a gas turbine… (more)

WIESE, ASHLEY PETER

2014-01-01T23:59:59.000Z

249

Air quality monitoring and modelling techniques for street canyons: the Paris  

E-Print Network [OSTI]

2000-37 Air quality monitoring and modelling techniques for street canyons: the Paris experience S of developing efficient air quality monitoring and modelling methodologies to cover the needs of public health, published in "Air Pollution Conference 2000, Cambridge : United Kingdom (2000)" #12;1 Introduction In recent

Paris-Sud XI, Université de

250

Parallel Implementation of a Large-Scale 3-D Air Pollution Model  

E-Print Network [OSTI]

Parallel Implementation of a Large-Scale 3-D Air Pollution Model Tzvetan Ostromsky1 and Zahari-4000 Roskilde, Denmark, zz@dmu.dk; http://www.dmu.dk/AtmosphericEnvironment Abstract. Air pollution and analyzed. Keywords: air pollution model, system of PDE's, parallel algorithm, shared memory computer

Ostromsky, Tzvetan

251

Multiscale models of atmospheric mercury: bromine chemistry, air-sea exchange, and global transport  

E-Print Network [OSTI]

entrainment of RGM-rich air from the free troposphere (25­40%). Oxidation of Hg0 by Cl is minor (3Multiscale models of atmospheric mercury: bromine chemistry, air-sea exchange, and global transport Multiscale models of atmospheric mercury: bromine chemistry, air-sea exchange, and global transport Abstract

Holmes, Christopher D.

252

King Air flight RICO 2004/12/13 page 1 King Air N2UW flight report for December 13, 2004  

E-Print Network [OSTI]

repair of the air conditioner on the aircraft, a test flight was needed and was to be transformedKing Air flight ­ RICO ­ 2004/12/13 page 1 King Air N2UW flight report for December 13, 2004 Crew: Drew, Vali, Oolman, Glover After

Vali, Gabor

253

A machine learning model of Manhattan air pollution at high spatial resolution  

E-Print Network [OSTI]

A machine-learning model was created to predict air pollution at high spatial resolution in Manhattan, New York using taxi trip data. Urban air pollution increases morbidity and mortality through respiratory and cardiovascular ...

Keeler, Rachel H. (Rachel Heiden)

2014-01-01T23:59:59.000Z

254

Establish the Commercial Pacakge Air Conditioners and Commercial Warm Air Furnaces WG  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up from theDepartment ofEnergy.pdfApplications: Heating Cooling OPUBLICLeadcommercial

255

Longitudinal Analysis of Short term Bronchiolitis Air Pollution Association using Semi Parametric Models  

E-Print Network [OSTI]

pollution, semi parametric models. 1.1 Introduction Time-series studies of air pollution and health was an overestimation of the eect of air pollution on health. More recently, in a issue of Epidemiology, Ramsay et al1 Longitudinal Analysis of Short term Bronchiolitis Air Pollution Association using Semi Parametric

Mesbah, Mounir

256

Assessing Seasonal Confounding and Model Selection Bias in Air Pollution Epidemiology Using Positive and  

E-Print Network [OSTI]

July 15, 1999 #12;Abstract Much of the evidence for health e ects of particulate air pollution has come. We thus refer to the `air pollution hypothesis' to describe increased risk of health outcomes dueAssessing Seasonal Confounding and Model Selection Bias in Air Pollution Epidemiology Using

Washington at Seattle, University of

257

Timevarying coe#cient models for the analysis of air pollution and health outcome data  

E-Print Network [OSTI]

Time­varying coe#cient models for the analysis of air pollution and health outcome data Duncan Lee The potential health e#ects of exposure to ambient air pollution have been a major issue in public health for over fifty years. Numerous studies of air pollution and health data have shown a link between

Bath, University of

258

COMPUTATIONAL CHALLENGES IN THE NUMERICAL TREATMENT OF LARGE AIR POLLUTION MODELS  

E-Print Network [OSTI]

COMPUTATIONAL CHALLENGES IN THE NUMERICAL TREATMENT OF LARGE AIR POLLUTION MODELS I. DIMOV , K. GEORGIEVy, TZ. OSTROMSKY , R. J. VAN DER PASz, AND Z. ZLATEVx Abstract. The air pollution, and especially the reduction of the air pollution to some acceptable levels, is an important environmental problem, which

Dimov, Ivan

259

Modeling and Feedback Control for Air Flow Regulation in Deep Pits  

E-Print Network [OSTI]

1 Modeling and Feedback Control for Air Flow Regulation in Deep Pits Emmanuel WITRANT and Nicolas the air). It is clear that investigating automatic control solutions and minimizing the amount of pumped to the ground turbine control and distributed sensors within the shaft; 2. air quality regulation

Boyer, Edmond

260

Annals of Glaciology 51(54) 2010 1 Potential flow models of suspension current air pressure  

E-Print Network [OSTI]

Annals of Glaciology 51(54) 2010 1 Potential flow models of suspension current air pressure Barbara Physics, University of Cambridge, UK ABSTRACT. We present, analyse and discuss air pressure data from finite-volume chute flows of dry fine snow in air. These experiments have the correct similarity criteria

McElwaine, Jim

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Comparing Mainframe and Windows Server Transactions per kWh  

E-Print Network [OSTI]

..................................................................................................................................15 Air Conditioner (Heat Pump) Efficiency Units

Narasayya, Vivek

262

Integrated Air Pollution Control System (IAPCS), Executable Model (Version 4. 0) (for microcomputers). Model-Simulation  

SciTech Connect (OSTI)

The Integrated Air Pollution Control System (IAPCS) Cost Model is an IBM PC cost model that can be used to estimate the cost of installing SO2, NOx, and particulate matter control systems at coal-fired utility electric generating facilities. The model integrates various combinations of the following technologies: physical coal cleaning, coal switching, overfire air/low NOx burners, natural gas reburning, LIMB, ADVACATE, electrostatic precipitator, fabric filter, gas conditioning, wet lime or limestone FGD, lime spray drying/duct spray drying, dry sorbent injection, pressurized fluidized bed combustion, integrated gasification combined cycle, and pulverized coal burning boiler. The model generates capital, annualized, and unitized pollutant removal costs in either constant or current dollars for any year.

Not Available

1990-10-29T23:59:59.000Z

263

Air conditioning system  

DOE Patents [OSTI]

An air conditioner comprises a plurality of plates arranged in a successively stacked configuration with portions thereof having a spaced apart arrangement, and defining between successive adjacent pairs of plates at the spaced apart portions a first and second series of discrete alternating passages wherein a first air stream is passed through the first series of passages and a second air stream is passed through the second series of passages; and said stacked configuration of plates forming integrally therewith a liquid delivery means for delivering from a source a sufficient quantity of a liquid to the inside surfaces of the first series of fluid passages in a manner which provides a continuous flow of the liquid from a first end to a second end of the plurality of plates while in contact with the first air stream.

Lowenstein, Andrew; Miller, Jeffrey; Gruendeman, Peter; DaSilva, Michael

2005-02-01T23:59:59.000Z

264

Modeling of Air-Fuel Ratio Dynamics of Gasoline Combustion Engine with ARX Network  

E-Print Network [OSTI]

DS-06-1351 Modeling of Air-Fuel Ratio Dynamics of Gasoline Combustion Engine with ARX Network Tomás dynamics of gasoline engines during transient operation. With a collection of input-output data measured;Modeling of Air-Fuel Ratio Dynamics of Gasoline Combustion Engine with ARX Network I. INTRODUCTION

Johansen, Tor Arne

265

Modeling the pneumatic subsystem of a S-cam air brake system  

E-Print Network [OSTI]

The air brake system is one of the critical components in ensuring the safe operation of any commercial vehicle. This work is directed towards the development of a fault-free model of the pneumatic subsystem of the air brake system. This model can...

Coimbatore Subramanian, Shankar

2004-09-30T23:59:59.000Z

266

An Improved Global Model for Air-Sea Exchange of Mercury: High  

E-Print Network [OSTI]

An Improved Global Model for Air-Sea Exchange of Mercury: High Concentrations over the North by inputs from Hg enriched subsurface waters through entrainment and Ekman pumping. Globally, subsurface). Previous efforts to model Hg air-sea exchange (2) and atmospheric transport (4-6) have been unable

Holmes, Christopher D.

267

A model for an under floor air distribution system Y.J.P. Lina,*, P.F. Lindenb  

E-Print Network [OSTI]

cool air from above. This geometrical design induces entrainment of warm air at the top of the roomA model for an under floor air distribution system Y.J.P. Lina,*, P.F. Lindenb a Energy Abstract We present a simplified model of an underfloor air distribution (UFAD) system consisting

Linden, Paul F.

268

Demand models for U.S. domestic air passenger markets  

E-Print Network [OSTI]

The airline industry in recent years has suffered from the adverse effects of top level planning decisions based upon inaccurate demand forecasts. The air carriers have recognized the immediate need to develop their ...

Eriksen, Steven Edward

1978-01-01T23:59:59.000Z

269

air dispersion modeling: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

case of fans, or indirectly, in the case of heat exchangers, which impose loads on the chiller and boiler plant. Air-handling units can comprise a myriad of subsystems (fans,...

270

Recent developments in orifice meter and flow conditioner research  

SciTech Connect (OSTI)

In 1969 concerns were raised regarding the validity of the orifice meter`s coefficient of discharge uncertainty. An effort to resolve these concerns resulted in an internationally supported research project which produced a new sharp-edged concentric orifice meter empirical database and coefficient of discharge equation. However, the new empirical database and coefficient of discharge equation did not account for all of the differences being encountered in orifice metering. And in 1986, as a derivative of the coefficient of discharge equation research, questions were raised regarding the influences of installation effects on the orifice meter`s coefficient of discharge. The 1986 EC research data indicated that the flow conditioner and straight pipe installation requirements of the flow measurement standards were inadequate to prevent biasing of the orifice meter`s coefficient of discharge by flow disturbances generated from upstream piping elements. Data generated from 1990 through 1993 by GRI sponsored SWRI and NIST research confirmed the original EC biasing and further identified differential pressure tap radial position sensitivity and velocity profile and swirl angle theory deficiencies. Current research is continuing to define installation effects influences and identify possible solutions.

LaNasa, P.J. [CPL and Associates, Houston, TX (United States)

1995-12-31T23:59:59.000Z

271

Impact of realistic hourly emissions profiles on air pollutants concentrations modelled with CHIMERE  

E-Print Network [OSTI]

Impact of realistic hourly emissions profiles on air pollutants concentrations modelled Keywords: Atmospheric composition European air quality Anthropogenic emissions a b s t r a c t Regional inputs data like anthropogenic surface emissions of NOx, VOCs and particulate matter. These emissions

Menut, Laurent

272

Look both ways: IE's Sarav Arunachalam models air pollution near roadways  

E-Print Network [OSTI]

Look both ways: IE's Sarav Arunachalam models air pollution near roadways IE Research Associate potent carcinogens. These toxic pollutants have strong associations with other adverse health effects and depletion of air pollution within the first 550 yards downwind of the roadway and look at exposure patterns

Engel, Jonathan

273

Modeling and Control of Aggregated Air Conditioning Loads Under Realistic Conditions  

E-Print Network [OSTI]

heaters are examples of TCLs. They use local hysteresis control to maintain either air or water units and water heaters is developed in [7] using detailed physical models. In all the aforementioned for a large fraction of electric demand. HVAC (Heating, Ventilation and air conditioning) systems and water

Zhang, Wei

274

An AirSea Coupled Skeleton Model for the MaddenJulian Oscillation* FEI LIU AND BIN WANG  

E-Print Network [OSTI]

An Air­Sea Coupled Skeleton Model for the Madden­Julian Oscillation* FEI LIU AND BIN WANG remains confined to atmospheric processes only. Here the authors study the role of air­sea in- teraction by implementing an oceanic mixed-layer (ML) model of Wang and Xie into the MJO skeleton model. In this new air

Wang, Bin

275

Dynamic Performance and Control of a Multilevel Universal Power Conditioner Leon M. Tolbert, Fang Z. Peng Thomas G. Habetler  

E-Print Network [OSTI]

-to-back diode-clamped inverters that constitute the universal power conditioner. An experimental verification. To meet the objectives detailed in these new premium power agreements, the implementation of advanced- clamped inverter into a universal power conditioner is an enticing prospect. For a multilevel universal

Tolbert, Leon M.

276

Integrated Air Pollution Control System (IAPCS), Executable Model and Source Model (version 4. 0) (for microcomputers). Model-Simulation  

SciTech Connect (OSTI)

The Integrated Air Pollution Control System (IAPCS) Cost Model is an IBM PC cost model that can be used to estimate the cost of installing SO2, NOx, and particulate matter control systems at coal-fired utility electric generating facilities. The model integrates various combinations of the following technologies: physical coal cleaning, coal switching, overfire air/low NOx burners, natural gas reburning, LIMB, ADVACATE, electrostatic precipitator, fabric filter, gas conditioning, wet lime or limestone FGD, lime spray drying/duct spray drying, dry sorbent injection, pressurized fluidized bed combustion, integrated gasification combined cycle, and pulverized coal burning boiler. The model generates capital, annualized, and unitized pollutant removal costs in either constant or current dollars for any year.

Not Available

1990-10-29T23:59:59.000Z

277

Using Product Specific Simulation Models in a Tool for Manual Commissioning of Air Handling Units  

E-Print Network [OSTI]

This short paper describes an outline of a tool for manual commissioning of air handling units. The prototype tool is implemented EES professional version that can generate standalone programs. The idea is to use the benefit of simulation models...

Eriksson, J.

2003-01-01T23:59:59.000Z

278

Diurnal cycle of air pollution in the Kathmandu Valley, Nepal: 2. Modeling results  

E-Print Network [OSTI]

After completing a 9-month field experiment studying air pollution and meteorology in the Kathmandu Valley, Nepal, we set up the mesoscale meteorological model MM5 to simulate the Kathmandu Valley's meteorology with a ...

Panday, Arnico K.

279

Air dispersion modeling of particulate matter from ground-level area sources  

E-Print Network [OSTI]

State Air Pollution Regulatory Agencies (SAPRAs) often use dispersion modeling to predict downwind concentrations of particulate matter (PM) from a facility. As such, a facility may be granted or denied an operating permit based on the results...

Meister, Michael Todd

2000-01-01T23:59:59.000Z

280

A mathematical model for air brake systems in the presence of leaks  

E-Print Network [OSTI]

A MATHEMATICAL MODEL FOR AIR BRAKE SYSTEMS IN THE PRESENCE OF LEAKS A Thesis by SRIVATSAN RAMARATHNAM Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE... August 2008 Major Subject: Mechanical Engineering A MATHEMATICAL MODEL FOR AIR BRAKE SYSTEMS IN THE PRESENCE OF LEAKS A Thesis by SRIVATSAN RAMARATHNAM Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment...

Ramaratham, Srivatsan

2008-10-10T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

AIR DISPERSION MODELING AT THE WASTE ISOLATION PILOT PLANT  

SciTech Connect (OSTI)

One concern at the Waste Isolation Pilot Plant (WIPP) is the amount of alpha-emitting radionuclides or hazardous chemicals that can become airborne at the facility and reach the Exclusive Use Area boundary as the result of a release from the Waste Handling Building (WHB) or from the underground during waste emplacement operations. The WIPP Safety Analysis Report (SAR), WIPP RCRA Permit, and WIPP Emergency Preparedness Hazards Assessments include air dispersion calculations to address this issue. Meteorological conditions at the WIPP facility will dictate direction, speed, and dilution of a contaminant plume of respirable material due to chronic releases or during an accident. Due to the paucity of meteorological information at the WIPP site prior to September 1996, the Department of Energy (DOE) reports had to rely largely on unqualified climatic data from the site and neighboring Carlsbad, which is situated approximately 40 km (26 miles) to the west of the site. This report examines the validity of the DOE air dispersion calculations using new meteorological data measured and collected at the WIPP site since September 1996. The air dispersion calculations in this report include both chronic and acute releases. Chronic release calculations were conducted with the EPA-approved code, CAP88PC and the calculations showed that in order for a violation of 40 CFR61 (NESHAPS) to occur, approximately 15 mCi/yr of 239Pu would have to be released from the exhaust stack or from the WHB. This is an extremely high value. Hence, it is unlikely that NESHAPS would be violated. A site-specific air dispersion coefficient was evaluated for comparison with that used in acute dose calculations. The calculations presented in Section 3.2 and 3.3 show that one could expect a slightly less dispersive plume (larger air dispersion coefficient) given greater confidence in the meteorological data, i.e. 95% worst case meteorological conditions. Calculations show that dispersion will decrease slightly if a more stable wind class is assumed, where very little vertical mixing occurs. It is recommended that previous reports which used fixed values for calculating the air dispersion coefficient be updated to reflect the new meteorological data, such as the WIPP Safety Analysis Report and the WIPP Emergency Preparedness Hazards Assessment. It is also recommended that uncertainty be incorporated into the calculations so that a more meaningful assessment of risk during accidents can be achieved.

Rucker, D.F.

2000-08-01T23:59:59.000Z

282

Efficiency of appliance models on the market before and after DOE standards  

SciTech Connect (OSTI)

Energy efficiency standards for appliances mandate that appliance manufacturers not manufacture or import models that have a test energy efficiency below a specified level after the standard effective date. Thus, appliance standards set a floor for energy efficiency. But do they also induce more significant changes in the efficiencies that manufacturers offer after the standard becomes effective? To address this question, we undertook an examination of before-standard and after-standard efficiency of models on the market for three products: (1) Refrigerators (1990, 1993, and 2001 standards); (2) Room air conditioners (1990 and 2000 standards); and (3) Gas furnaces (1992 standard).

Meyers, Stephen

2004-06-15T23:59:59.000Z

283

Demand response enabling technology development  

E-Print Network [OSTI]

battery voltage. NOTE: This device does not control the thermoelectric air conditioner on the plastic model house.

2006-01-01T23:59:59.000Z

284

Flow conditioner for fuel injector for combustor and method for low-NO.sub.x combustor  

DOE Patents [OSTI]

An injector for a gas turbine combustor including a catalyst coated surface forming a passage for feed gas flow and a channel for oxidant gas flow establishing an axial gas flow through a flow conditioner disposed at least partially within an inner wall of the injector. The flow conditioner includes a length with an interior passage opening into upstream and downstream ends for passage of the axial gas flow. An interior diameter of the interior passage smoothly reduces and then increases from upstream to downstream ends.

Dutta, Partha; Smith, Kenneth O.; Ritz, Frank J.

2013-09-10T23:59:59.000Z

285

Characterization of ambient air pollution for stochastic health models  

SciTech Connect (OSTI)

This research is an analysis of various measures of ambient air pollution useful in cross-sectional epidemiological investigations and rick assessments. The Chestnut Ridge area health effects investigation, which includes a cross-sectional study of respiratory symptoms in young children, is used as a case study. Four large coal-fired electric generating power plants are the dominant pollution sources in this area of western Pennsylvania. The air pollution data base includes four years of sulfur dioxide and five years of total suspended particulate concentrations at seventeen monitors. Some 70 different characterizations of pollution are constructed and tested. These include pollutant concentrations at various percentiles and averaging times, exceedence measures which show the amount of time a specified threshold concentration is exceeded, and several dosage measures which transform non-linear dose-response relationships onto pollutant concentrations.

Batterman, S.A.

1981-08-01T23:59:59.000Z

286

Market and behavioral barriers to energy efficiency: A preliminary evaluation of the case for tariff financing in California  

E-Print Network [OSTI]

Central Air Conditioners and Heat Pumps. ” Department ofrecent central air conditioner and heat pump purchasers only

Fujita, K. Sydny

2012-01-01T23:59:59.000Z

287

Delivering Energy Efficiency to Middle Income Single Family Households  

E-Print Network [OSTI]

water heater replacement, air conditioner Assumptions behindreplacements (e.g. , furnace, water heater, air conditioner,

Zimring, Mark

2012-01-01T23:59:59.000Z

288

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network [OSTI]

water heater replacement, air conditioner replacement, solarwater heater replacement, air conditioner replacement, solar

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

289

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network [OSTI]

replacement, air conditioner replacement, solar thermalreplacement, air conditioner replacement, solar thermal

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

290

Lesson 36: Housing and Accommodation  

E-Print Network [OSTI]

/ mikeka [air conditioner / air conditioners] [mat / mats] CHUMBA CHA KULA CHAKULA / CHUMBA CHA MAANKULI

291

Classroom Vocabulary Classroom Vocabulary [msamiati wa darasani  

E-Print Network [OSTI]

] [wall clock] [map / maps] [air conditioner / air conditioners] [picture / pictures] [drawing / drawings

292

Pollution Control in a Manufacturing System Stochastic Models for Analysis and Control of Air Pollution  

E-Print Network [OSTI]

Pollution Control in a Manufacturing System Stochastic Models for Analysis and Control of Air Pollution in a Manufacturing System Jan, 1, 2005 Technical Report SOPTL-05-01 Missouri University of Science models that can be used for controlling pollution in a manufacturing system. The models are developed

Gosavi, Abhijit

293

An air itinerary choice model based on a mixed RP/SP dataset  

E-Print Network [OSTI]

An air itinerary choice model based on a mixed RP/SP dataset Bilge Atasoy Michel Bierlaire April/SP dataset. The aim of the combination of the two datasets is to exploit the variability of the SP data is modeled as a latent class. In this study we develop an itinerary choice model based on a real dataset

Bierlaire, Michel

294

From Modelica Models to Fault Diagnosis in Air Handling Units Raymond Sterling1  

E-Print Network [OSTI]

From Modelica Models to Fault Diagnosis in Air Handling Units Raymond Sterling1 , Peter Struss2 Handling Unit (AHU). This solution is derived from a general first-principle Modelica model and exploits 4 presents the modelica models and its calibration. In section 5 an example of the complete tool

Cengarle, María Victoria

295

Modeling and control of an open accumulator Compressed Air Energy Storage (CAES) system for wind turbines q  

E-Print Network [OSTI]

Modeling and control of an open accumulator Compressed Air Energy Storage (CAES) system for wind compressed air energy storage. Maximizes energy production, levels load, downsizes electrical parts, meets presents the modeling and control for a novel Compressed Air Energy Storage (CAES) system for wind turbines

Li, Perry Y.

296

Empirical Modeling of a Rolling-Piston Compressor Heat Pump for Predictive Control in Low-Lift Cooling  

E-Print Network [OSTI]

Inverter-driven variable-capacity air conditioners, heat pumps, and chillers can provide energy-efficient cooling, particularly at part-load capacity. Varying the capacity of vapor compression systems enables operation at ...

Gayeski, Nicholas

297

A review of polymer-based water conditioners for reduction of handling-related injury  

SciTech Connect (OSTI)

Fish are coated with an external layer of protective mucus. This layer serves as the primary barrier against infection or injury, reduces friction, and plays a role in ionic and osmotic regulation. However, the mucus layer is easily disturbed when fish are netted, handled, transported, stressed, or subjected to adverse water conditions. Water additives containing polyvinylpyrrolidone (PVP) or proprietary polymers have been used to prevent the deleterious effects of mucus layer disturbances in the commercial tropical fish industry, aquaculture, and for other fisheries management purposes. This paper reviews research on the effectiveness of water conditioners, and examines the contents and uses of a wide variety of commercially available water conditioners. Water conditioners containing polymers may reduce external damage to fish held in containers during scientific experimentation, including surgical implantation of electronic tags. However, there is a need to empirically test the effectiveness of water conditioners at preventing damage to and promoting healing of the mucus layer. A research agenda is provided to advance the science related to the use of water conditions to improve the condition of fish during handling and tagging.

Harnish, Ryan A.; Colotelo, Alison HA; Brown, Richard S.

2011-01-01T23:59:59.000Z

298

Impacts of contaminant storage on indoor air quality: Model development  

E-Print Network [OSTI]

environment. The model is applied to describe the interaction between formaldehyde in building materials to the timescale of depletion of the compound from the storage medium, however, the total exposure will depend in the indoor environment, which occurs over much shorter depletion timescales of the order of days. This model

299

Calendar Year 2008 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network [OSTI]

air cleaners Room air conditioners Scanners Servers Set-topBoilers • Central Air Conditioners and Air-Source HeatHeat Pump -Central Air Conditioner -Gas Furnace -Oil

Homan, GregoryK

2010-01-01T23:59:59.000Z

300

Air Pollution Physics and Chemistry EAS 6790 Home Work Assignment No. 2, Air Pollution Meteorology: Box Model  

E-Print Network [OSTI]

Air Pollution Physics and Chemistry EAS 6790 Fall 2008 Home Work Assignment No. 2, Air Pollution to interpret measurements made in Mexico City. Focus mainly on the discussions relating to nitrate aerosol

Weber, Rodney

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Simulation of aerosol dynamics: A comparative review of algorithms used in air quality models  

SciTech Connect (OSTI)

A comparative review of algorithms currently used in air quality models to simulate aerosol dynamics is presented. This review addresses coagulation, condensational growth, nucleation, and gas/particle mass transfer. Two major approaches are used in air quality models to represent the particle size distribution: (1) the sectional approach in which the size distribution is discretized into sections and particle properties are assumed to be constant over particle size sections and (2) the modal approach in which the size distribution is approximated by several modes and particle properties are assumed to be uniform in each mode. The results of this study provide useful information to select algorithms to simulate aerosol dynamics in air quality models and to improve the accuracy of existing algorithms.

Zhang, Y.; Seigneur, C.; Seinfeld, J.H.; Jacobson, M.Z.; Binkowski, F.S.

1999-01-01T23:59:59.000Z

302

Mathematics and Computers in Simulation 65 (2004) 557577 Parallel runs of a large air pollution model on a  

E-Print Network [OSTI]

-three decades. The need to establish reliable control strategies for the air pollution levels will become evenMathematics and Computers in Simulation 65 (2004) 557­577 Parallel runs of a large air pollution 20 January 2004; accepted 21 January 2004 Abstract Large-scale air pollution models can successfully

303

Modeling of air currents in the Gulf Region  

SciTech Connect (OSTI)

The Atmospheric Release Advisory Capability modeled the wind flow in the Gulf Region in order to make projections of the Kuwait oil fires pollution dispersion. Extensive meteorological models incorporating explicit terrain influences to the flow fields were routinely employed through a six month international assessment support effort organized by the World Meteorological Organization and US scientific research agencies. Results show generally close agreement with visible imagery of the smoke plumes as detected by meteorological satellites. However, there are some examples of significant disagreement or failure of the meteorological models. These failures are most likely directly linked to missing or unavailable weather observations.

Sullivan, T.J.; Ellis, J.S.; Foster, C.S.; Foster, K.T.; Baskett, R.L.; Nasstrom, J.S.; Schalk, W.W.

1992-04-14T23:59:59.000Z

304

Lessons learned in modeling Underfloor Air Distribution system  

E-Print Network [OSTI]

UFAD variable speed fan coil units are not straightforwarda variable speed fan coil unit model object was developed inand a constant volume fan coil unit, used only for heating.

Lee, Kwang Ho; Schiavon, Stefano; Webster, Tom; Bauman, Fred; Feng, Jingjuan; Hoyt, Tyler

2011-01-01T23:59:59.000Z

305

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

L ABORATORY China Energy Efficiency Round Robin TestingNeed to Improve the Energy Efficiency of Energy Consumingfor Implementing the China Energy Efficiency Label System (

Zhou, Nan

2010-01-01T23:59:59.000Z

306

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network [OSTI]

the current cost of production of 3.5 Rs per kWh. It isthe average cost of production to be 3.50 Rs. per kWh, or $the cost of production significantly at 4.80 Rs. per kWh. As

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

307

Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners  

E-Print Network [OSTI]

chapter we discuss market, energy consumption and technologyeffective Room AC energy efficiency market transformation42 Chapter 3 Room AC Market and Energy Consumption

Shah, Nihar

2014-01-01T23:59:59.000Z

308

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

E-Print Network [OSTI]

017F.PDF KEMA, Inc. 2011. PJM Empirical Analysis of DemandMethods. Prepared for the PJM Markets Implementation~/media/markets-ops/dsr/pjm-analysis-of-dr-baseline-methods-

Bode, Josh

2013-01-01T23:59:59.000Z

309

Analysis of Efficiency Standards for Air Conditioners, Heat Pumps, and Other Products  

Reports and Publications (EIA)

A series of analyses showing the impacts of each of the selected provisions of the bills on energy supply, demand, and prices, macroeconomic variables where feasible, import dependence, and emissions.

2002-01-01T23:59:59.000Z

310

Advanced Thin Film Thermoelectric Systems forEfficient Air-Conditioner...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

& Publications Sheetak will work on developing a full scale prototype of its low cost heat pump water heater. These solid state heat pumping elements can be implemented in low...

311

E-Print Network 3.0 - air conditioners Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Majid - School of Engineering Science, Simon Fraser University Collection: Engineering ; Energy Storage, Conversion and Utilization 2 T H E U N I V E R S I T Y O F C H I C A G O C...

312

E-Print Network 3.0 - air conditioner units Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Majid - School of Engineering Science, Simon Fraser University Collection: Engineering ; Energy Storage, Conversion and Utilization 2 T H E U N I V E R S I T Y O F C H I C A G O C...

313

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

decrease in energy consumption per unit GDP in the "Eleventh40-50% reduction in energy consumption per unit GDP by 2020measured by energy consumption per unit GDP in the “The 11th

Zhou, Nan

2010-01-01T23:59:59.000Z

314

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

E-Print Network [OSTI]

measurements using smart meter household data produce theof program households. Smart meters lower the cost of usingsample sizes with smart meter data can be far larger than

Bode, Josh

2013-01-01T23:59:59.000Z

315

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

further passed the Energy Efficiency (Labeling of Products)must be marked with an energy efficiency label informingconsumers of the energy efficiency level of related

Zhou, Nan

2010-01-01T23:59:59.000Z

316

Five ENERGY STAR Room Air Conditioners Fail Testing | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecordFederal Registry CommentsOverview »FINDINGDepartmentFive ENERGY STAR

317

DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomentheATLANTA, GA - U.S. Department of Energy Secretary StevenDeploymentForms

318

Tips for Running an Air Conditioner Without Breaking the Bank | Department  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas ConchasPassiveSubmittedStatusButler Tina Butler Tina-Butler.jpg Tina L. P.nuclearTipsof

319

DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana. DOCUMENTSof Energy DOEDOEAVAILABLEDepartment ofHeldViolating Minimum

320

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Deliciouscritical_materials_workshop_presentations.pdf MoreProgram |DOEInfrastructure Working420.1B FACILITYHeat

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

was maybe tested with less refrigerant charge than in China.Differences in the refrigerant charges are not confirmed byvacuum treatment, charge 850g±5g R22 refrigerant for sample

Zhou, Nan

2010-01-01T23:59:59.000Z

322

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

E-Print Network [OSTI]

Ernest Orlando Lawrence Berkeley National Laboratory. LBNL-2008. Ernest Orlando Lawrence Berkeley National Laboratory.Ernest Orlando Lawrence Berkeley National Laboratory. LBNL-

Bode, Josh

2013-01-01T23:59:59.000Z

323

Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners  

E-Print Network [OSTI]

1986.Priceeffectsofenergy-efficient technologies—a study ofSAITO et al] EDR, “Technology Overview: Economizers”, Energyresources/publications/technology-overviews/technology-

Shah, Nihar

2014-01-01T23:59:59.000Z

324

Advanced Thin Film Thermoelectric Systems forEfficient Air-Conditioners |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartment of EnergyAdministrative2| DepartmentEnergy 2Waste Heat at GM

325

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergy Cooperation | Department ofEnergy IsTestimonials WorkerDepartmentHouse ofEnergy

326

Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists' Research |Regulation Services2014 UpdateTeach-Ins | Department of Energy|

327

Modelling an Air Traffic Control Environment Bayesian Belief Networks  

E-Print Network [OSTI]

be measured and monitored. The project is a collaborative venture between the RADAR Group in the Department, Professor Bob Malcolm & Roger Shaw RADAR Group, Department of Computer Science, Queen Mary, University level model of ATC operations spanning a number of defensive barriers from airspace design, through

Neil, Martin

328

AIR FLOW MODELING IN DEEP WELLS: APPLICATION TO MINING VENTILATION  

E-Print Network [OSTI]

consumption and increase of electricity prices in a context of worldwide competition also mo- tivate system control and energy consumption op- timization. Two different levels of complexity are pro- posed]. This short historical overview also illustrates the parallel evolution of magnetic ventilation modeling

Paris-Sud XI, Université de

329

Evaluation of a Local Air Conditioning Duty Cycling Device as a Load Management Tool  

E-Print Network [OSTI]

the air conditioners were controlled. The local control device and the direct control device were both found to reduce demand of the compressor by about 0.65 kW at 100°F ambient temperature. Also, the kW reduction achieved was found to increase with higher...

Schneider, K.; Thedford, M.

1986-01-01T23:59:59.000Z

330

Forest models: their development and potential applications for air pollution effects research  

SciTech Connect (OSTI)

As research tools for evaluating the effects of chronic air pollution stress, forest simulation models offer one means of integrating forest growth and development data with generalized indices of pollution stress. This approach permits consideration of both the competitive interactions of trees in the forest stand and the influences of the stage of stand development on sensitivity of component species. A review of forest growth models, including tree, stand, and gap models, is provided as a means of evaluating relative strengths, weaknesses, and limits of applicability of representative examples of each type. Data from recent simulations with a gap model of eastern deciduous forest responses to air pollution stress are presented to emphasize the potential importance of competition in modifying individual species' responses in a forest stand. Recent developments in dendroecology are discussed as a potential mechanism for model validation and extended application.

Shugart, H.H.; McLaughlin, S.B.; West, D.C.

1980-01-01T23:59:59.000Z

331

Mathematical modeling of air pollution emissions and dispersion near intersections  

E-Print Network [OSTI]

are calculated by approximating the crosswind finite line source equation with: 10 N c- Q2x u I - (z - E + 2kL) CNT 2 P o k~CN 2o 2 z. z. I (z + E + 2kL) I 2 + exp 2o z. (6) where: n " total number of elements CNT = number of multtple reflections... 142 142 143 145 145 145 149 158 C. Explanation aud Location of Files D. TEXIN Model Computer Listing 166 VITA 243 LIST OF TABLES Table Passenger car equivalency (PCE) values for left turn effects Page 36 Lane-use factors 38 Level...

Nelli, James Patrick

1982-01-01T23:59:59.000Z

332

Mathematical Model of an Air-Filled Alpha Stirling Refrigerator Patrick McFarlane,1, a)  

E-Print Network [OSTI]

into a useful temperature difference. Though there are a few current applications of Stirling engines in energy of the work done on Stirling cycle-based machines. Although the re- view focused on engines, the analysisMathematical Model of an Air-Filled Alpha Stirling Refrigerator Patrick McFarlane,1, a) Fabio

Sen, Mihir

333

Aggregated Modeling and Control of Air Conditioning Loads for Demand Response  

E-Print Network [OSTI]

1 Aggregated Modeling and Control of Air Conditioning Loads for Demand Response Wei Zhang, Member, IEEE Abstract--Demand response is playing an increasingly impor- tant role in the efficient loads is especially important to evaluate the effec- tiveness of various demand response strategies

Zhang, Wei

334

A Method for Simulating Heat Recovery Systems Using AirModel in Implementations of the ASHRAE Simplified Energy Analysis Procedure  

E-Print Network [OSTI]

exchanger to verify the return air ratio. In this comparison, the recovered energy from the return air was equalized with the heat transfer of the heat exchanger model. An example of this methodology was used to simulate the HVAC system with a heat... to be measured for further investigation to verify the AirModel simulation. This method can be applied in Energy Plus and other simulation tools/software to simulate the building exhaust energy recovery. Acknowledgements The work of this paper...

Liu, C.; Zeig, M.; Claridge, D. E.; Wei, G.; Bruner, H.; Turner, W. D.

2005-01-01T23:59:59.000Z

335

Model Based Commissioning Tool for Air-Conditioning Distribution Systems-APCBC  

E-Print Network [OSTI]

of VWV System 4. Example of VAV System 5. Conclusions 2 ESL-IC-14-09-06 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 ? Energy consumption of air and water distribution in air...-09-06 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 1. Issues 2. Simulation Model of Distribution System 3. Example of VWV System 4. Example of VAV System 5. Conclusions 7 ESL-IC-14...

Yoshida, H.; Noda, T.

2014-01-01T23:59:59.000Z

336

Source Contributions to VOC's to Ozone Formation in Southeast Texas Using a Source-oriented Air Quality Model  

E-Print Network [OSTI]

AQS) from August 16, 2000 to September 7, 2000. Environmental Protection Agency (EPA)?s Community Scale Air Quality Model (CMAQ) version 4.6 was used as a host model to include a revised Statewide Air Pollution Research Center (SAPRC99) photochemical...

Krishnan, Anupama

2011-08-08T23:59:59.000Z

337

Hydrodynamic Modeling of Air Blast Propagation from the Humble Redwood Chemical High Explosive Detonations Using GEODYN  

SciTech Connect (OSTI)

Two-dimensional axisymmetric hydrodynamic models were developed using GEODYN to simulate the propagation of air blasts resulting from a series of high explosive detonations conducted at Kirtland Air Force Base in August and September of 2007. Dubbed Humble Redwood I (HR-1), these near-surface chemical high explosive detonations consisted of seven shots of varying height or depth of burst. Each shot was simulated numerically using GEODYN. An adaptive mesh refinement scheme based on air pressure gradients was employed such that the mesh refinement tracked the advancing shock front where sharp discontinuities existed in the state variables, but allowed the mesh to sufficiently relax behind the shock front for runtime efficiency. Comparisons of overpressure, sound speed, and positive phase impulse from the GEODYN simulations were made to the recorded data taken from each HR-1 shot. Where the detonations occurred above ground or were shallowly buried (no deeper than 1 m), the GEODYN model was able to simulate the sound speeds, peak overpressures, and positive phase impulses to within approximately 1%, 23%, and 6%, respectively, of the actual recorded data, supporting the use of numerical simulation of the air blast as a forensic tool in determining the yield of an otherwise unknown explosion.

Chipman, V D

2011-09-20T23:59:59.000Z

338

Seasonal versus Episodic Performance Evaluation for an Eulerian Photochemical Air Quality Model  

SciTech Connect (OSTI)

This study presents detailed evaluation of the seasonal and episodic performance of the Community Multiscale Air Quality (CMAQ) modeling system applied to simulate air quality at a fine grid spacing (4 km horizontal resolution) in central California, where ozone air pollution problems are severe. A rich aerometric database collected during the summer 2000 Central California Ozone Study (CCOS) is used to prepare model inputs and to evaluate meteorological simulations and chemical outputs. We examine both temporal and spatial behaviors of ozone predictions. We highlight synoptically driven high-ozone events (exemplified by the four intensive operating periods (IOPs)) for evaluating both meteorological inputs and chemical outputs (ozone and its precursors) and compare them to the summer average. For most of the summer days, cross-domain normalized gross errors are less than 25% for modeled hourly ozone, and normalized biases are between {+-}15% for both hourly and peak (1 h and 8 h) ozone. The domain-wide aggregated metrics indicate similar performance between the IOPs and the whole summer with respect to predicted ozone and its precursors. Episode-to-episode differences in ozone predictions are more pronounced at a subregional level. The model performs consistently better in the San Joaquin Valley than other air basins, and episodic ozone predictions there are similar to the summer average. Poorer model performance (normalized peak ozone biases <-15% or >15%) is found in the Sacramento Valley and the Bay Area and is most noticeable in episodes that are subject to the largest uncertainties in meteorological fields (wind directions in the Sacramento Valley and timing and strength of onshore flow in the Bay Area) within the boundary layer.

Jin, Ling; Brown, Nancy J.; Harley, Robert A.; Bao, Jian-Wen; Michelson, Sara A; Wilczak, James M

2010-04-16T23:59:59.000Z

339

Energy Savings Through Application of Model Predictive Control to an Air Separation Facility  

E-Print Network [OSTI]

Energy Savings Through Application of Model Predictive Control to an Air Separation Facility Thomas C. Hanson PauiF. Scharf Manager Senior Engineering Associate Process Development Process Control Technology Praxair, Inc., Tonawanda, New York...TM based operator interface was developed by Praxair to make the system usable in our operations. 174 ESL-IE-96-04-24 Proceedings from the Eighteenth Industrial Energy Technology Conference, Houston, TX, April 17-18, 1996 Benefits overview MPC has...

Hanson, T. C.; Scharf, P. F.

340

AeroSys: Order (2011-SCE-1624) | Department of Energy  

Office of Environmental Management (EM)

that certain models of space-constrained central air conditioners and air conditioning heat pumps comply with the applicable energy conservation standards; and (2) manufactured...

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

AeroSys: Test Notice (2009) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

the compliance of various models of central air conditioners and air conditioning heat pumps with the applicable energy conservation standards. A cover letter describes the...

342

AeroSys: Order (2010-CE-01/0201 and 2010-SE-0302) | Department...  

Broader source: Energy.gov (indexed) [DOE]

in commerce in the U.S. various models of air conditioners and air conditioning heat pumps that did not comport with the applicable energy conservation standards. In...

343

Heat Controller: Noncompliance Determination (2014-SE-15004)...  

Office of Environmental Management (EM)

a Notice of Noncompliance Determination to Heat Controller, Inc. finding that the room air conditioner distributed in commerce by Heat Controller as Comfort Aire brand models...

344

Modeling the Air Flow in the 3410 Building Filtered Exhaust Stack System  

SciTech Connect (OSTI)

Additional ventilation capacity has been designed for the 3410 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and will include ductwork to incorporate the new fan into the existing stack. Stack operations will involve running various two-fan combinations at any given time. The air monitoring system of the existing two-fan stack was previously found to be in compliance with the ANSI/HPS N13.1-1999 standard, however it is not known if the modified (three-fan) system will comply. Subsequently, a full-scale three-dimensional (3-D) computational fluid dynamics (CFD) model of the modified stack system has been created to examine the sampling location for compliance with the standard. The CFD modeling results show good agreement with testing data collected from the existing 3410 Building stack and suggest that velocity uniformity and flow angles will remain well within acceptance criteria when the third fan and associated ductwork is installed. This includes two-fan flow rates up to 31,840 cfm for any of the two-fan combinations. For simulation cases in which tracer gas and particles are introduced in the main duct, the model predicts that both particle and tracer gas coefficients of variance (COVs) may be larger than the acceptable 20 percent criterion of the ANSI/HPS N13.1-1999 standard for each of the two-fan, 31,840 cfm combinations. Simulations in which the tracers are introduced near the fans result in improved, though marginally acceptable, COV values for the tracers. Due to the remaining uncertainty that the stack will qualify with the addition of the third fan and high flow rates, a stationary air blender from Blender Products, Inc. is considered for inclusion in the stack system. A model of the air blender has been developed and incorporated into the CFD model. Simulation results from the CFD model that includes the air blender show striking improvements in tracer gas mixing and tracer particle dispersion. The results of these simulations suggest the air blender should be included in the stack system to ensure qualification of the stack.

Recknagle, Kurtis P.; Barnett, J. M.; Suffield, Sarah R.

2013-01-23T23:59:59.000Z

345

Mitigating the Impacts of Uncontrolled Air Flow on Indoor Environmental Quality and Energy Demand in Non-Residential Buildings  

SciTech Connect (OSTI)

This multi-faceted study evaluated several aspects of uncontrolled air flows in commercial buildings in both Northern and Southern climates. Field data were collected from 25 small commercial buildings in New York State to understand baseline conditions for Northern buildings. Laboratory wall assembly testing was completed at Syracuse University to understand the impact of typical air leakage pathways on heat and moisture transport within wall assemblies for both Northern and Southern building applications. The experimental data from the laboratory tests were used to verify detailed heat and moisture (HAM) simulation models that could be used to evaluate a wider array of building applications and situations. Whole building testing at FSEC's Building Science Laboratory (BSL) systematically evaluated the energy and IAQ impacts of duct leakage with various attic and ceiling configurations. This systematic test carefully controlled all aspects of building performance to quantify the impact of duct leakage and unbalanced flow. The newest features of the EnergyPlus building simulation tool were used to model the combined impacts of duct leakage, ceiling leakage, unbalanced flows, and air conditioner performance. The experimental data provided the basis to validate the simulation model so it could be used to study the impact of duct leakage over a wide range of climates and applications. The overall objective of this project was to transfer work and knowledge that has been done on uncontrolled air flow in non-residential buildings in Florida to a national basis. This objective was implemented by means of four tasks: (1) Field testing and monitoring of uncontrolled air flow in a sample of New York buildings; (2) Detailed wall assembly laboratory measurements and modeling; (3) Whole building experiments and simulation of uncontrolled air flows; and (4) Develop and implement training on uncontrolled air flows for Practitioners in New York State.

Hugh I. Henderson; Jensen Zhang; James B. Cummings; Terry Brennan

2006-07-31T23:59:59.000Z

346

Table Contents Page i 2013 Nonresidential Compliance Manual January 2014  

E-Print Network [OSTI]

Table B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner ....................................................................................11 Table B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps...........12 Central Air Conditioner Test Methods

347

Improved model for the analysis of air fluorescence induced by electrons  

E-Print Network [OSTI]

A model recently proposed for the calculation of air-fluorescence yield excited by electrons is revisited. Improved energy distributions of secondary electrons and a more realistic Monte Carlo simulation including some additional processes have allowed us to obtain more accurate results. The model is used to study in detail the relationship between fluorescence intensity and deposited energy in a wide range of primary energy (keVs - GeVs). In addition, predictions on the absolute value of the fluorescence efficiency in the absence of collisional quenching will be presented and compared with available experimental data.

F. Arqueros; F. Blanco; J. Rosado

2008-07-24T23:59:59.000Z

348

Exploring the concept of compressed air energy storage (CAES) in lined rock caverns at shallow depth: A modeling study of air tightness and energy balance  

SciTech Connect (OSTI)

This paper presents a numerical modeling study of coupled thermodynamic, multiphase fluid flow and heat transport associated with underground compressed air energy storage (CAES) in lined rock caverns. Specifically, we explored the concept of using concrete lined caverns at a relatively shallow depth for which constructing and operational costs may be reduced if air tightness and stability can be assured. Our analysis showed that the key parameter to assure long-term air tightness in such a system was the permeability of both the concrete lining and the surrounding rock. The analysis also indicated that a concrete lining with a permeability of less than 1×10{sup -18} m{sup 2} would result in an acceptable air leakage rate of less than 1%, with the operational pressure range between 5 and 8 MPa at a depth of 100 m. It was further noted that capillary retention properties and the initial liquid saturation of the lining were very important. Indeed, air leakage could be effectively prevented when the air-entry pressure of the concrete lining is higher than the operational air pressure and when the lining is kept moist at a relatively high liquid saturation. Our subsequent energy-balance analysis demonstrated that the energy loss for a daily compression and decompression cycle is governed by the air-pressure loss, as well as heat loss by conduction to the concrete liner and surrounding rock. For a sufficiently tight system, i.e., for a concrete permeability off less than 1×10{sup -18} m{sup 2}, heat loss by heat conduction tends to become proportionally more important. However, the energy loss by heat conduction can be minimized by keeping the air-injection temperature of compressed air closer to the ambient temperature of the underground storage cavern. In such a case, almost all the heat loss during compression is gained back during subsequent decompression. Finally, our numerical simulation study showed that CAES in shallow rock caverns is feasible from a leakage and energy efficiency viewpoint. Our numerical approach and energy analysis will next be applied in designing and evaluating the performance of a planned full-scale pilot test of the proposed underground CAES concept.

Kim, H.-M.; Rutqvist, J.; Ryu, D.-W.; Choi, B.-H.; Sunwoo, C.; Song, W.-K.

2011-07-15T23:59:59.000Z

349

ACEEE Summer Study on Energy in Industry, West Point, NY, July 19-22. 1 Modeling and Simulation of Air Compressor Energy Use  

E-Print Network [OSTI]

compressor energy use to estimate energy savings in compressed air systems from air use reduction and other pressure, and for modeling the change in system pressure as function of compressed air storage volume assessments of mid-sized industries, we found that the average unit energy cost of compressed air ranges from

Kissock, Kelly

350

Aggregated Modeling and Control of Air Conditioning Loads for Demand Response  

SciTech Connect (OSTI)

Demand response is playing an increasingly important role in the efficient and reliable operation of the electric grid. Modeling the dynamic behavior of a large population of responsive loads is especially important to evaluate the effectiveness of various demand response strategies. In this paper, a highly-accurate aggregated model is developed for a population of air conditioning loads. The model effectively includes statistical information of the population, systematically deals with load heterogeneity, and accounts for second-order dynamics necessary to accurately capture the transient dynamics in the collective response. Based on the model, a novel aggregated control strategy is designed for the load population under realistic conditions. The proposed controller is fully responsive and achieves the control objective without sacrificing end-use performance. The proposed aggregated modeling and control strategies are validated through realistic simulations using GridLAB-D. Extensive simulation results indicate that the proposed approach can effectively manage a large number of air conditioning systems to provide various demand response services, such as frequency regulation and peak load reduction.

Zhang, Wei; Lian, Jianming; Chang, Chin-Yao; Kalsi, Karanjit

2013-06-21T23:59:59.000Z

351

Creating and Implementing a Regularized Monitoring and Enforcement System for China's Mandatory Standards and Energy Information Label for Appliances  

E-Print Network [OSTI]

for 11 products including: refrigerators; air conditioners;on room air-conditioners, which covered products from 29for 11 products including: refrigerators; air conditioners;

Lin, Jiang

2008-01-01T23:59:59.000Z

352

Compliance and Verification of Standards and Labeling Programs in China: Lessons Learned  

E-Print Network [OSTI]

covering two products (refrigerators and air conditioners),and unitary air conditioners) and 15 other products areprogram by products and location room air conditioners Fix

Saheb, Yamina

2011-01-01T23:59:59.000Z

353

Status of China's Energy Efficiency Standards and Labels for Appliances and International Collaboration  

E-Print Network [OSTI]

is applied to four products including: air conditioners;to cover four products including: air conditioners; house-size - for three products (refrigerators, air-conditioners

Zhou, Nan

2010-01-01T23:59:59.000Z

354

Status of the Local Enforcement of Energy Efficiency Standards and Labeling Program in China  

E-Print Network [OSTI]

Check-Testing Sample Product Room air conditioners Self-in part, for five products: room air conditioners, electricCompliance Results Products Inspected Room air conditioners

Zhou, Nan

2013-01-01T23:59:59.000Z

355

Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms  

E-Print Network [OSTI]

a prototype improved heat pump air conditioner was developedwith standard 10 SEER heat pump air conditioner equipment.generated by the wall mount heat pump air conditioner (HPAC)

Apte, Michael; Michael G. Apte, Bourassa Norman, David Faulkner, Alfred T. Hodgson,; Toshfumi Hotchi, Michael Spears, Douglas P. Sullivan, and Duo Wang

2008-01-01T23:59:59.000Z

356

Cash for Coolers  

E-Print Network [OSTI]

for refrigerator and air conditioner replacement and allof refrigerator and air-conditioner replacement on householdthat replacement of residential air conditioners would save

Davis, Lucas W.; Fuchs, Alan; Gertler, Paul J.

2012-01-01T23:59:59.000Z

357

Impact of Large Scale Energy Efficiency Programs On Consumer Tariffs and Utility Finances in India  

E-Print Network [OSTI]

like refrigerator and air conditioner replacements. Thisiv) Replacement of conventional air conditioners by energy-ii) Replacement of conventional air conditioners by energy-

Abhyankar, Nikit

2011-01-01T23:59:59.000Z

358

Cash for Coolers  

E-Print Network [OSTI]

of refrigerator and air-conditioner replacement on householdfor refrigerator and air conditioner replacement and allassociated with air-conditioner replacement were to be

Davis, Lucas W.; Fuchs, Alan; Gertler, Paul J.

2012-01-01T23:59:59.000Z

359

Impact of Large Scale Energy Efficiency Programs On Consumer Tariffs and Utility Finances in India  

E-Print Network [OSTI]

like refrigerator and air conditioner replacements. This5-star air conditioners are the efficient replacement, withiv) Replacement of conventional air conditioners by energy-

Abhyankar, Nikit

2011-01-01T23:59:59.000Z

360

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in China  

E-Print Network [OSTI]

television and an air conditioner. In the future, ownershipresidential room air conditioners require the largesttelevision and an air conditioner. In the future, ownership

McNeil, Michael A.

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Current Status and Future Scenarios of Residential Building Energy Consumption in China  

E-Print Network [OSTI]

in MJ /household-year. Air conditioner and refrigerator endand 217.4% for air conditioner in Japan in 2000 (IEEJ,appliances including air conditioner, refrigerator, clothes

Zhou, Nan

2010-01-01T23:59:59.000Z

362

RESIDENTIAL THERMOSTATS: COMFORT CONTROLS IN CALIFORNIA HOMES  

E-Print Network [OSTI]

Measures on Residential Air Conditioner Loads. Proc. ACEEEDeterminants of Central Air Conditioner Duty Cycles. Proc.at the number of air conditioners that might actually

Meier, Alan K.

2008-01-01T23:59:59.000Z

363

TWOZONE USERS MANUAL. 2d ed  

E-Print Network [OSTI]

cooler, improved air conditioner algorithm, ability to readcooling the house with air-conditioner, evaporative-cooler= starting month of air-conditioner (AC) operation. = ending

Gadgil, A.J.

2008-01-01T23:59:59.000Z

364

Customer Impact Evaluation for the 2009 Southern California Edison Participating Load Pilot  

E-Print Network [OSTI]

duration interruptions of air-conditioners. Still, we should14 3.2.2 Typical Summer Air Conditioner15 Table 3.3 Air Conditioner

Gifford, William

2010-01-01T23:59:59.000Z

365

Recommended Parameter Values for GENII Modeling of Radionuclides in Routine Air and Water Releases  

SciTech Connect (OSTI)

The GENII v2 code is used to estimate dose to individuals or populations from the release of radioactive materials into air or water. Numerous parameter values are required for input into this code. User-defined parameters cover the spectrum from chemical data, meteorological data, agricultural data, and behavioral data. This document is a summary of parameter values that reflect conditions in the United States. Reasonable regional and age-dependent data is summarized. Data availability and quality varies. The set of parameters described address scenarios for chronic air emissions or chronic releases to public waterways. Considerations for the special tritium and carbon-14 models are briefly addressed. GENIIv2.10.0 is the current software version that this document supports.

Snyder, Sandra F.; Arimescu, Carmen; Napier, Bruce A.; Hay, Tristan R.

2012-11-01T23:59:59.000Z

366

Exploring the concept of compressed air energy storage (CAES) in lined rock caverns at shallow depth: A modeling study of air tightness and energy balance  

E-Print Network [OSTI]

wind- diesel-compressed air energy storage system for remotestudy for the compressed air energy storage technology bydesign of compressed air energy storage electric power

Kim, H.-M.

2012-01-01T23:59:59.000Z

367

Cloud Model Evaluation Using Radiometric Measurements from the Airborne Multiangle Imaging Spectroradiometer (AirMISR)  

SciTech Connect (OSTI)

Detailed information on cloud properties is needed to vigorously test retrieval algorithms for satellite and ground-based remote sensors. The inherent complexity of clouds makes this information difficult to obtain from observations alone and cloud resolving models are often used to generating synthetic datasets that can be used as proxies for real data. We test the ability of a cloud resolving model to reproduce cloud structure in a case study of low-level clouds observed by the Earth Observing System (EOS) validation program in north central Oklahoma on March 3, 2000. A three-dimensional radiative transfer model is applied to synthetic cloud properties generated by a high-resolution three-dimensional cloud model in order to simulate the top of atmosphere radiances. These synthetic radiances are then compared with observations from the airborne Multiangle Imaging SpectroRadiometer (AirMISR), flown on the NASA ER-2 high-altitude aircraft.

Ovtchinnikov, Mikhail; Marchand, Roger T.

2007-03-01T23:59:59.000Z

368

Influence of rain on air-sea gas exchange: Lessons from a model ocean David T. Ho,1,2  

E-Print Network [OSTI]

Influence of rain on air-sea gas exchange: Lessons from a model ocean David T. Ho,1,2 Christopher J-sea gas exchange: Lessons from a model ocean, J. Geophys. Res., 109, C08S18, doi:10.1029/2003JC001806. 1; published 1 July 2004. [1] Rain has been shown to significantly enhance the rate of air-water gas exchange

Ho, David

369

User's manual for heat-pump seasonal-performance model (SPM) with selected parametric examples  

SciTech Connect (OSTI)

The Seasonal Performance Model (SPM) was developed to provide an accurate source of seasonal energy consumption and cost predictions for the evaluation of heat pump design options. The program uses steady state heat pump performance data obtained from manufacturers' or Computer Simulation Model runs. The SPM was originally developed in two forms - a cooling model for central air conditioners and heat pumps and a heating model for heat pumps. The original models have undergone many modifications, which are described, to improve the accuracy of predictions and to increase flexibility for use in parametric evaluations. Insights are provided into the theory and construction of the major options, and into the use of the available options and output variables. Specific investigations provide examples of the possible applications of the model. (LEW)

Not Available

1982-06-30T23:59:59.000Z

370

Near-field dispersal modeling for liquid fuel-air explosives  

SciTech Connect (OSTI)

The near-field, explosive dispersal of a liquid into air has been explored using a combination of analytical and numerical models. The near-field flow regime is transient, existing only as long as the explosive forces produced by the detonation of the burster charge dominate or are approximately equal in magnitude to the aerodynamic drag forces on the liquid. The near-field model provides reasonable initial conditions for the far-field model, which is described in a separate report. The near-field model consists of the CTH hydrodynamics code and a film instability model. In particular, the CTH hydrodynamics code is used to provide initial temperature, pressure, and velocity fields, and bulk material distribution for the far-field model. The film instability model is a linear stability model for a radially expanding fluid film, and is used to provide a lower bound on the breakup time and an upper and lower bound on the initial average drop diameter for the liquid following breakup. Predictions of the liquid breakup time and the initial arithmetic average drop diameter from the model compare favorably with the sparse experimental data. 26 refs., 20 figs., 8 tabs.

Gardner, D.R.

1990-07-01T23:59:59.000Z

371

Using Local and Regional Air Quality Modeling and Source Apportionment Tools to Evaluate Vehicles and Biogenic Emission Factors  

E-Print Network [OSTI]

and inventories of CO, NO_(x) and VOCs from on-road vehicles estimated by vehicle emission factor models and biogenic emissions of isoprene estimated by a popular biogenic emission model are evaluated using local and regional scale air quality modeling and source...

Kota, Sri H

2014-07-25T23:59:59.000Z

372

Experimental investigation and modeling of a direct-coupled PV/T air collector  

SciTech Connect (OSTI)

Photovoltaic/thermal (PV/T) systems refer to the integration of photovoltaic and solar thermal technologies into one single system, in that both useful heat energy and electricity are produced. The impetus of this paper is to model a direct-coupled PV/T air collector which is designed, built, and tested at a geographic location of Kerman, Iran. In this system, a thin aluminum sheet suspended at the middle of air channel is used to increase the heat exchange surface and consequently improve heat extraction from PV panels. This PV/T system is tested in natural convection and forced convection (with two, four and eight fans operating) and its unsteady results are presented in with and without glass cover cases. A theoretical model is developed and validated against experimental data, where good agreement between the measured values and those calculated by the simulation model were achieved. Comparisons are made between electrical performance of the different modes of operation, and it is concluded that there is an optimum number of fans for achieving maximum electrical efficiency. Also, results show that setting glass cover on photovoltaic panels leads to an increase in thermal efficiency and decrease in electrical efficiency of the system. (author)

Shahsavar, A.; Ameri, M. [Department of Mechanical Engineering, Faculty of Engineering, Shahid Bahonar University, Kerman (Iran, Islamic Republic of); Energy and Environmental Engineering Research Center, Shahid Bahonar University, Kerman (Iran, Islamic Republic of)

2010-11-15T23:59:59.000Z

373

A model for thermally driven heat and air transport in passive solar buildings  

SciTech Connect (OSTI)

A model for transient interzone heat and air flow transport in passive solar buildings is presented incorporating wall boundary layers in stratified zones, and with interzone transport via apertures (doors and windows). The model includes features that have been observed in measurements taken in more than a dozen passive solar buildings. The model includes integral formulations of the laminar and turbulent boundary layer equations for the vertical walls which are then coupled to a one-dimensional core model for each zone. The cores in each zone exchange mass and energy through apertures that are modeled by an orifice type equation. The procedure is transient in that time dependence is retained only in the core equations which are solved by an explicit method. The model predicts room stratification of about 2/sup 0/C/m (1.1/sup 0/F/ft) for a room-to-room temperature difference of 0.56/sup 0/C(1/sup 0/F) which is in general agreement with the data.

Jones, G.F.; Balcomb, J.D.; Otis, D.R.

1985-01-01T23:59:59.000Z

374

Model for thermally driven heat and air transport in passive solar buildings  

SciTech Connect (OSTI)

A model for transient interzone heat and air flow transport in passive solar buildings is presented incorporating wall boundary layers in stratified zones, and with interzone transport via apertures (doors and windows). The model includes features that have been observed in measurements taken in more than a dozen passive solar buildings. The model includes integral formulations of the laminar and turbulent boundary layer equations for the vertical walls which are then coupled to a one-dimensional core model for each zone. The cores in each zone exchange mass and energy through apertures that are modeled by an orifice type equation. The procedure is transient in that time dependence is retained only in the core equations which are solved by an explicit method. The model predicts room stratification of about 2/sup 0/C/m (1.1/sup 0/F/ft) for a room-to-room temperature difference of 0.56/sup 0/C(1/sup 0/F) which is in general agreement with the data. 38 references, 10 figures, 1 table.

Jones, G.F.; Balcomb, J.D.; Otis, D.R.

1985-01-01T23:59:59.000Z

375

Attempt to estimate measurement uncertainty in the Air Force Toxic Chemical Dispersion (AFTOX) model. Master's thesis  

SciTech Connect (OSTI)

The Air Force Toxic Chemical Dispersion (AFTOX) model is a Gaussian puff dispersion model that predicts plumes, concentrations, and hazard distances of toxic chemical spills. A measurement uncertainty propagation formula derived by Freeman et al. (1986) is used within AFTOX to estimate resulting concentration uncertainties due to the effects of data input uncertainties in wind speed, spill height, emission rate, and the horizontal and vertical Gaussian dispersion parameters, and the results are compared to true uncertainties as estimated by standard deviations computed by Monte Carlo simulations. The measurement uncertainty uncertainty propagation formula was found to overestimate measurement uncertainty in AFTOX-calculated concentrations by at least 350 percent, with overestimates worsening with increasing stability and/or increasing measurement uncertainty.

Zettlemoyer, M.D.

1990-01-01T23:59:59.000Z

376

Regression analysis of residential air-conditioning energy consumption at Dhahran, Saudi Arabia  

SciTech Connect (OSTI)

The energy consumption of a house air conditioner located at Dhahran, Saudi Arabia, is modeled as a function of weather parameters and total (global) solar radiation on a horizontal surface. The selection of effective parameters that significantly influence energy consumption is carried out using general stepping regression methods. The problem of collinearity between the regressors is also investigated. The final model involves parameters of total solar radiation on a horizontal surface, wind speed, and temperature difference between the indoor and outdoor condition. However, the model coefficients are functions of relative humidity and/or temperature difference between the indoor and outdoor condition. Model adequacy is examined by the residual analysis technique. Model validation is carried out by the data-splitting technique. The sensitivity of the model indicates that relative humidity and temperature difference strongly influence the cooling energy consumption. It was found that an increase in relative humidity from 20% to 100% can cause a 100% increase in cooling energy consumption during the high cooling season.

Abdel-Nabi, D.Y.; Zubair, S.M.; Abdelrahman, M.A.; Bahel, V. (Energy Systems Group, Div. of Energy Resources, Research Inst., King Fahd Univ. of Petroleum and Minerals, Dhahran (SA))

1990-01-01T23:59:59.000Z

377

MODELING THE TRANSPORT AND CHEMICAL EVOLUTION OF ONSHORE AND OFFSHORE EMISSIONS AND THEIR IMPACT ON LOCAL AND REGIONAL AIR QUALITY USING A VARIABLE-GRID-RESOLUTION AIR QUALITY MODEL  

SciTech Connect (OSTI)

This document, the project's first semiannual report, summarizes the research performed from 04/17/2003 through 10/16/2003. Portions of the research in several of the project's eight tasks were completed, and results obtained are briefly presented. We have tested the applicability of two different atmospheric boundary layer schemes for use in air quality model simulations. Preliminary analysis indicates that a scheme that uses sophisticated atmospheric boundary physics resulted in better simulation of atmospheric circulations. We have further developed and tested a new surface data assimilation technique to improve meteorological simulations, which will also result in improved air quality model simulations. Preliminary analysis of results indicates that using the new data assimilation technique results in reduced modeling errors in temperature and moisture. Ingestion of satellite-derived sea surface temperatures into the mesoscale meteorological model led to significant improvements in simulated clouds and precipitation compared to that obtained using traditional analyzed sea surface temperatures. To enhance the capabilities of an emissions processing system so that it can be used with our variable-grid-resolution air quality model, we have identified potential areas for improvements. Also for use in the variable-grid-resolution air quality model, we have tested a cloud module offline for its functionality, and have implemented and tested an efficient horizontal diffusion algorithm within the model.

Kiran Alapaty

2003-12-01T23:59:59.000Z

378

Check-Testing of Manufacturer Self Reported Labeling Data & Compliance with MEPS  

E-Print Network [OSTI]

2 Room Air-conditioner Air-conditioner Initial test- ing Re-HFS BJS BJS HFS BJS BJS Non- compliant* Air-conditioner9 Table 5. Room Air Conditioner 2000

Zhou, Nan

2008-01-01T23:59:59.000Z

379

Method and apparatus for analog signal conditioner for high speed, digital x-ray spectrometer  

DOE Patents [OSTI]

A signal processing system which accepts input from an x-ray detector-preamplifier and produces a signal of reduced dynamic range for subsequent analog-to-digital conversion. The system conditions the input signal to reduce the number of bits required in the analog-to-digital converter by removing that part of the input signal which varies only slowly in time and retaining the amplitude of the pulses which carry information about the x-rays absorbed by the detector. The parameters controlling the signal conditioner's operation can be readily supplied in digital form, allowing it to be integrated into a feedback loop as part of a larger digital x-ray spectroscopy system.

Warburton, William K. (1300 Mills St., Menlo Park, CA 94025); Hubbard, Bradley (Santa Cruz, CA)

1999-01-01T23:59:59.000Z

380

MODELING AND TRAJECTORY OPTIMIZATION OF WATER SPRAY COOLING IN A LIQUID PISTON AIR COMPRESSOR  

E-Print Network [OSTI]

and expansion has many applications in pneumatic and hydraulic systems, including in the Compressed Air Energy Storage (CAES) system for offshore wind turbine that has recently been proposed in [1,2]. Since the air

Li, Perry Y.

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

3-DOF potential air flow manipulation by inverse modeling control Anne Delettre, Guillaume J. Laurent, Nadine Le Fort-Piat and Christophe Varnier  

E-Print Network [OSTI]

3-DOF potential air flow manipulation by inverse modeling control Anne Delettre, Guillaume J. Laurent, Nadine Le Fort-Piat and Christophe Varnier Abstract-- Potential air flows can be used to perform non- prehensile contactless manipulations of objects gliding on air- hockey table. In this paper, we

Paris-Sud XI, Université de

382

Frontal Scale AirSea Interaction in High-Resolution Coupled Climate Models FRANK O. BRYAN, ROBERT TOMAS, AND JOHN M. DENNIS  

E-Print Network [OSTI]

Frontal Scale Air­Sea Interaction in High-Resolution Coupled Climate Models FRANK O. BRYAN, ROBERT The emerging picture of frontal scale air­sea interaction derived from high-resolution satellite observations have revealed fundamentally different air­sea coupling mechanisms on the scale of ocean fronts

Kurapov, Alexander

383

IMPROVED SEMI-PARAMETRIC TIME SERIES MODELS OF AIR POLLUTION AND MORTALITY  

E-Print Network [OSTI]

series analyses of air pollution and health attracted the attention of the scientific community, policy uncertainty in time series studies of air pollution and health. This discovery delayed the completion) for six "criteria" air pollutants at a level that protects the public's health (Environmental Protection

Dominici, Francesca

384

Understanding the Dehumidification Performance of Air-Conditioning Equipment at Part-Load Conditions  

SciTech Connect (OSTI)

Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions--especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and may negatively impact indoor air quality. This report summarizes the results of a comprehensive project to better understand and quantify the moisture removal (dehumidification) performance of cooling coils at part-load conditions. A review of the open literature was initially conducted to learn from previous research on this topic. Detailed performance measurements were then collected for eight cooling coils in a controlled laboratory setting to understand the impact of coil geometry and operating conditions on transient moisture condensation and evaporation by the coils. Measurements of cooling coil dehumidification performance and space humidity levels were also collected at seven field test sites. Finally, an existing engineering model to predict dehumidification performance degradation for single-stage cooling equipment at part-load conditions (Henderson and Rengarajan 1996) was enhanced to include a broader range of fan control strategies and an improved theoretical basis for modeling off-cycle moisture evaporation from cooling coils. The improved model was validated with the laboratory measurements, and this report provides guidance for users regarding proper model inputs. The model is suitable for use in computerized calculation procedures such as hourly or sub-hourly building energy simulation programs (e.g., DOE's EnergyPlus building energy simulation program, http://www.energyplus.gov ).

Don B. Shirey III; Hugh I. Henderson Jr; Richard A. Raustad

2006-01-01T23:59:59.000Z

385

The role of size-dependent dry deposition of sulfate aerosol in a three-dimensional Eulerian air quality model  

SciTech Connect (OSTI)

The Regional Particulate Model, a three-dimensional Eulerian air quality model, was developed to investigate aerosol particle issues of important to the US EPA and to meet the demands of the Clean Air Act amendments of 1990. In addition to aerosol dynamics such as growth and coagulation, the model includes photochemistry, transport, and deposition. A new formulation of dry deposition as a function of the aerosol size distribution has been incorporated into the model. This formulation allows for the representation of dry deposition of total particle number and total particle mass by deposition velocities specifically formulated for these two quantities as a function of particle size. Results for the dry deposition of sulfate mass from the new model will be compared with those from the Tagged Species Engineering Model for a variety of local conditions. The behavior of the aerosol size distribution responding to the new formulation will also be discussed.

Binkowski, F.S. [NOAA, Research Triangle Park, NC (United States); Shankar, U. [MCNC, Research Triangle Park, NC (United States)

1994-12-31T23:59:59.000Z

386

Tariff-based analysis of commercial building electricity prices  

E-Print Network [OSTI]

Central Air Conditioners and Heat Pump Energy ConservationUnitary Air Conditioners and Heat Pumps ANOPR Technical

Coughlin, Katie M.; Bolduc, Chris A.; Rosenquist, Greg J.; Van Buskirk, Robert D.; McMahon, James E.

2008-01-01T23:59:59.000Z

387

Current Status and Future Scenarios of Residential Building Energy Consumption in China  

E-Print Network [OSTI]

stove district heating heat pump air conditioner Table 2Heat Pump Percentage (%) Heat Pump Air Conditioner District

Zhou, Nan

2010-01-01T23:59:59.000Z

388

Modeling Air Quality Near Freeways Using a Three Dimensional Eulerian Model  

E-Print Network [OSTI]

experiment, conducted at Michigan in 1976. Sensitivity of the model to meteorology and traffic-related parameters are studied in detail. In the second case, the spatial distribution of ozone, carbon monoxide, NOx and 1,3-Butadiene near a simulated 8-lane...

Kota, Sri Harsha

2010-10-12T23:59:59.000Z

389

PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED INTO A DWELLING  

E-Print Network [OSTI]

PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED.peuportier@mines-paristech.fr, Tel.: +33 1 40 51 91 51 ABSTRACT An inverter-driven air-to-air heat pump model has been developped capacity air-to-air heat pump coupled with temperate air sources (crawlspace, attic, sunspace, heat

Paris-Sud XI, Université de

390

Source- and Age-Resolved Mechanistic Air Quality Models: Model Development and Application in Southeast Texas  

E-Print Network [OSTI]

naphthalene (a), acenaphthene (b), acenaphthylene (c), fluorene (d), and phenanthrene (e) and relevant observation from 2007 to 2010 at DRPK. .............................. 122 Figure 5-5. Model predicted APAH1 and APAH2 concentrations as well as the APAHT... of naphthalene, methylnaphthalene, acenaphthylene, and acenaphthene. They estimated that SOA production from oxidation of PAHs emitted from mobile sources in Houston could account for more than 10% of the SOA formed from emissions from mobile sources...

Zhang, Hongliang

2012-07-16T23:59:59.000Z

391

Impacts of cool cities on air quality: A preliminary modeling assessment for Nashville TN, Dallas TX and Atlanta GA  

SciTech Connect (OSTI)

Previous atmospheric modeling efforts that concentrated on the Los Angeles Basin suggested beneficial and significant air quality impacts from cool cities strategies. This paper discusses an extension of similar modeling efforts to three regions, Atlanta GA, Dallas - Ft. Worth TX, and Nashville TN, that experience smog and air quality problems. According to the older ozone air quality standard (120 ppb), these regions were classified as serious, moderate, and marginal, respectively, but may be out of compliance with respect to the newer, 80-ppb/8-hours standard. Results from this exploratory modeling work suggest a range of possible impacts on meteorological and air quality conditions. For example, peak ozone concentrations during each region's respective episode could be decreased by 1-6 ppb (conservative and optimistic scenarios, respectively) in Nashville, 5-15 ppb in Dallas - Fort Worth, and 5-12 ppb in Atlanta following implementation of cool cities. The reductions are generally smaller than those obtained from simulating the Los Angeles Basin but are still significant. In all regions, the simulations suggest, the net, domain-wide effects of cool cities are reductions in ozone mass and improvements in air quality. In Atlanta, Nashville, and Dallas, urban areas benefiting from reduced smog reach up to 8460, 7350, and 12870 km{sup 2} in area, respectively. Results presented in this paper should be taken as exploratory and preliminary. These will most likely change during a more comprehensive modeling study to be started soon with the support of the US Environmental Protection Agency. The main purpose of the present project was to obtain the initial data (emission inventories) for these regions, simulate meteorological conditions, and perform preliminary sensitivity analysis. In the future, additional regions will be simulated to assess the potential of cool cities in improving urban air quality.

Taha, Haider

1998-06-15T23:59:59.000Z

392

IEA Heat Pump Conference 2011, 16 -19 May 2011, Tokyo, Japan DYNAMIC MODELING OF AN AIR SOURCE HEAT PUMP WATER  

E-Print Network [OSTI]

. Compared to those water heaters, heat pump water heating systems can supply much more heat just with the same amount of electric input used for electric water heaters. The ASHPWH absorbs heat from the ambient- 1 - 10th IEA Heat Pump Conference 2011, 16 - 19 May 2011, Tokyo, Japan DYNAMIC MODELING OF AN AIR

Paris-Sud XI, Université de

393

Implementation and Application of SAPRC07 and MCM Mechanisms in the Multi-scale Community Air Quality Model  

E-Print Network [OSTI]

mechanism. In this study, two state-of-the-science photochemical mechanisms, SAPRC07 and Master Chemical Mechanism (MCM) v3.1, were implemented in the Community Multi-scale Air Quality Model (CMAQ) version 4.6 developed by the US EPA to study a high ozone (O...

Li, Jingyi

2012-02-14T23:59:59.000Z

394

Modeling the exit velocity of a compressed air cannon Z. J. Rohrbach, T. R. Buresh, and M. J. Madsen  

E-Print Network [OSTI]

whether the expansion of the gas in the cannon is an adiabatic or an isothermal process. We built an air cannon that utilizes a diaphragm valve to release the pressurized gas and found that nei- ther process, launched from a cannon with initial gas pressure P0. We model the cannon as a reservoir of volume V0

Madsen, Martin John

395

Use of Source Term and Air Dispersion Modeling in Planning Demolition of Highly Alpha-Contaminated Buildings  

SciTech Connect (OSTI)

The current cleanup of structures related to cold-war production of nuclear materials includes the need to demolish a number of highly alpha-contaminated structures. The process of planning for the demolition of such structures includes unique challenges related to ensuring the protection of both workers and the public. Pre-demolition modeling analyses were conducted to evaluate potential exposures resulting from the proposed demolition of a number of these structures. Estimated emission rates of transuranic materials during demolition are used as input to an air-dispersion model. The climatological frequencies of occurrence of peak air and surface exposures at locations of interest are estimated based on years of hourly meteorological records. The modeling results indicate that downwind deposition is the main operational limitation for demolition of a highly alpha-contaminated building. The pre-demolition modeling directed the need for better contamination characterization and/or different demolition methods—and in the end, provided a basis for proceeding with the planned demolition activities. Post-demolition modeling was also conducted for several contaminated structures, based on the actual demolition schedule and conditions. Comparisons of modeled and monitoring results are shown. Recent monitoring data from the demolition of a UO3 plant shows increments in concentrations that were previously identified in the pre-demolition modeling predictions; these comparisons confirm the validity and value of the pre-demolition source-term and air dispersion computations for planning demolition activities for other buildings with high levels of radioactive contamination.

Droppo, James G.; Napier, Bruce A.; Rishel, Jeremy P.; Bloom, Richard W.

2011-06-22T23:59:59.000Z

396

A simplified model for estimating population-scale energy impacts of building envelope air-tightening and mechanical ventilation retrofits  

SciTech Connect (OSTI)

Changing the air exchange rate of a home (the sum of the infiltration and mechanical ventilation airflow rates) affects the annual thermal conditioning energy. Large-scale changes to air exchange rates of the housing stock can significantly alter the residential sector's energy consumption. However, the complexity of existing residential energy models is a barrier to the accurate quantification of the impact of policy changes on a state or national level. The Incremental Ventilation Energy (IVE) model developed in this study combines the output of simple air exchange models with a limited set of housing characteristics to estimate the associated change in energy demand of homes. The IVE model was designed specifically to enable modellers to use existing databases of housing characteristics to determine the impact of ventilation policy change on a population scale. The IVE model estimates of energy change when applied to US homes with limited parameterisation are shown to be comparable to the estimates of a well-validated, complex residential energy model.

Logue, J. M.; Turner, W. J.N.; Walker, I. S.; Singer, B. C.

2015-01-01T23:59:59.000Z

397

Proposal for a Vehicle Level Test Procedure to Measure Air Conditioning Fuel Use  

SciTech Connect (OSTI)

The air-conditioning (A/C) compressor load significantly impacts the fuel economy of conventional vehicles and the fuel use/range of plug-in hybrid electric vehicles (PHEV). A National Renewable Energy Laboratory (NREL) vehicle performance analysis shows the operation of the air conditioner reduces the charge depletion range of a 40-mile range PHEV from 18% to 30% in a worst case hot environment. Designing for air conditioning electrical loads impacts PHEV and electric vehicle (EV) energy storage system size and cost. While automobile manufacturers have climate control procedures to assess A/C performance, and the U.S. EPA has the SCO3 drive cycle to measure indirect A/C emissions, there is no automotive industry consensus on a vehicle level A/C fuel use test procedure. With increasing attention on A/C fuel use due to increased regulatory activities and the development of PHEVs and EVs, a test procedure is needed to accurately assess the impact of climate control loads. A vehicle thermal soak period is recommended, with solar lamps that meet the SCO3 requirements or an alternative heating method such as portable electric heaters. After soaking, the vehicle is operated over repeated drive cycles or at a constant speed until steady-state cabin air temperature is attained. With this method, the cooldown and steady-state A/C fuel use are measured. This method can be run at either different ambient temperatures to provide data for the GREEN-MAC-LCCP model temperature bins or at a single representative ambient temperature. Vehicles with automatic climate systems are allowed to control as designed, while vehicles with manual climate systems are adjusted to approximate expected climate control settings. An A/C off test is also run for all drive profiles. This procedure measures approximate real-world A/C fuel use and assess the impact of thermal load reduction strategies.

Rugh, J. P.

2010-04-01T23:59:59.000Z

398

Model Predictive Control of Regulation Services from Commercial Buildings to the Smart Grid Mehdi Maasoumy, Borhan M. Sanandaji, Alberto Sangiovanni-Vincentelli, and Kameshwar Poolla  

E-Print Network [OSTI]

such as air conditioners, heat pumps, water heaters, and refrigerators [3], [4]. Recently, [5], [6] showed demonstrate that the demand-side flexi- bility of the Heating Ventilation and Air Conditioning (HVAC) system that about 20% of the total electricity consumption in the United States is used by residential TCLs

Sanandaji, Borhan M.

399

Modeling of coupled thermodynamic and geomechanical performance of underground compressed air energy storage (CAES) in lined rock caverns  

SciTech Connect (OSTI)

We applied coupled nonisothermal, multiphase fluid flow and geomechanical numerical modeling to study the coupled thermodynamic and geomechanical performance of underground compressed air energy storage (CAES) in concrete-lined rock caverns. The paper focuses on CAES in lined caverns at relatively shallow depth (e.g., 100 m depth) in which a typical CAES operational pressure of 5 to 8 MPa is significantly higher than both ambient fluid pressure and in situ stress. We simulated a storage operation that included cyclic compression and decompression of air in the cavern, and investigated how pressure, temperature and stress evolve over several months of operation. We analyzed two different lining options, both with a 50 cm thick low permeability concrete lining, but in one case with an internal synthetic seal such as steel or rubber. For our simulated CAES system, the thermodynamic analysis showed that 96.7% of the energy injected during compression could be recovered during subsequent decompression, while 3.3% of the energy was lost by heat conduction to the surrounding media. Our geomechanical analysis showed that tensile effective stresses as high as 8 MPa could develop in the lining as a result of the air pressure exerted on the inner surface of the lining, whereas thermal stresses were relatively smaller and compressive. With the option of an internal synthetic seal, the maximum effective tensile stress was reduced from 8 to 5 MPa, but was still in substantial tension. We performed one simulation in which the tensile tangential stresses resulted in radial cracks and air leakage though the lining. This air leakage, however, was minor (about 0.16% of the air mass loss from one daily compression) in terms of CAES operational efficiency, and did not significantly impact the overall energy balance of the system. However, despite being minor in terms of energy balance, the air leakage resulted in a distinct pressure increase in the surrounding rock that could be quickly detected using pressure monitoring outside the concrete lining.

Rutqvist, J.; Kim, H. -M.; Ryu, D. -W.; Synn, J. -H.; Song, W. -K.

2012-02-01T23:59:59.000Z

400

Central Air Conditioners","Heat Pumps","Individual Air Conditioners","District Chilled Water","Central Chillers","Packaged  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia,(Million Barrels) Crude Oil Reserves in Nonproducing Reservoirs (MillionExpected FutureYearFeet)Feet)Process:4.

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Central Air Conditioners","Heat Pumps","Individual Air Conditioners","District Chilled Water","Central Chillers","Packaged  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia,(Million Barrels) Crude Oil Reserves in Nonproducing Reservoirs (MillionExpected

402

A numerical model and scaling relationship for energetic electron beams propagating in air  

SciTech Connect (OSTI)

Scaling relationships for energy loss and scattering are combined with a particle code to construct a purely algebraic expression for the energy deposited by an energetic electron beam injected into field-free homogeneous air. An algebraic formulation is possible because the mean free paths for the major collisional processes depend similarly on density and energy above 1 keV. Accordingly, the spatial behavior of an initially cold pencil beam is approximately self-similar when expressed in terms of the nominal beam range, provided the beam energy at injection exceeds several keV. Since a warm and broad beam can always be decomposed into a series of cold pencil beams, the total energy deposited can be obtained through a simple sum. With such a model, the ionization and excitation generated by a beam can be computed quickly and easily at every point in space. Similar formulations can be developed for other media using particle codes or experimental data. In liquids or solids, the energy deposited is quickly converted to heat and ultimately to melting and/or vaporization of the material.

Fernsler, R. F.; Slinker, S. P. [Plasma Physics Division, Naval Research Laboratory, Washington, DC 20375 (United States); Lambrakos, S. G. [Materials Science and Technology Division, Naval Research Laboratory, Washington, DC 20375 (United States)

2008-09-15T23:59:59.000Z

403

Air-Source Heat Pumps | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomen Owned SmallOfCoal_Budget_Fact_Sheet.pdfAir conditioners cost U.S.When properly

404

Modeling of coupled thermodynamic and geomechanical performance of underground compressed air energy storage (CAES) in lined rock caverns  

E-Print Network [OSTI]

Williams, Compressed air energy storage: Theory, resources,study for the compressed air energy storage technology byplant for compressed air energy storage power generation,

Rutqvist, J.

2013-01-01T23:59:59.000Z

405

Modeling of coupled thermodynamic and geomechanical performance of underground compressed air energy storage (CAES) in lined rock caverns  

E-Print Network [OSTI]

Williams, Compressed air energy storage: Theory, resources,for the compressed air energy storage technology by thefor compressed air energy storage power generation, Japan

Rutqvist, J.

2013-01-01T23:59:59.000Z

406

Air PSE (Problem Solving Environment)  

E-Print Network [OSTI]

PSE - 1 Air PSE (Problem Solving Environment) MODELLING OF AIR POLLUTION IN THE LOS ANGELES BASIN WITH AIR PSE Developed by Prof. Donald Dabdub Computational Environmental Sciences Laboratory Mechanical COMPUTER MODELS An air pollution model is a computer program that computes how the different chemical

Nizkorodov, Sergey

407

Desiccant Enhanced Evaporative Air-Conditioning (DEVap): Evaluation of a New Concept in Ultra Efficient Air Conditioning  

SciTech Connect (OSTI)

NREL has developed the novel concept of a desiccant enhanced evaporative air conditioner (DEVap) with the objective of combining the benefits of liquid desiccant and evaporative cooling technologies into an innovative 'cooling core.' Liquid desiccant technologies have extraordinary dehumidification potential, but require an efficient cooling sink. DEVap's thermodynamic potential overcomes many shortcomings of standard refrigeration-based direct expansion cooling. DEVap decouples cooling and dehumidification performance, which results in independent temperature and humidity control. The energy input is largely switched away from electricity to low-grade thermal energy that can be sourced from fuels such as natural gas, waste heat, solar, or biofuels.

Kozubal, E.; Woods, J.; Burch, J.; Boranian, A.; Merrigan, T.

2011-01-01T23:59:59.000Z

408

A diffusion approximation approach to stochastic modeling of air conditioning type loads  

E-Print Network [OSTI]

that the air conditioning unit is on and off. In the followino equations, TNIN and TNAX are the lower and upper limit temperatures of the thermostat deadband and To is the outside temperature. Gi 2Gw To Tw Cw Ci $ QeXt To - outside temperature Tw - wall... temperature Ti - inside temperature Gw ? thermal conductance of wall Gi - thermal conductance of air Cw - thermal capacitance of wall Ci ? thermal capacitance of air Qe - rated capacity of cooling unit Xt - zero-one process describing the switching...

Roy, Teresa Henryka

1981-01-01T23:59:59.000Z

409

Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges  

SciTech Connect (OSTI)

Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40percent cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

Phadke, Amol; Abhyankar, Nikit; Shah, Nihar

2014-06-19T23:59:59.000Z

410

Assessing the Impact of Measurement Policy on the Accuracy of Certified Energy Efficiency Ratio for Split-System Air Conditioners  

E-Print Network [OSTI]

Efficiency and Renewable Energy, Building Technologiesand Renewable Energy, Office of Building Technology, State,

Yu, Bingyi

2013-01-01T23:59:59.000Z

411

Development of Temperature and Humidity-Based Indicators for Diagnosing Problems in Low Tonnage, Split System Air Conditioners  

E-Print Network [OSTI]

of HVAC systems for building optimization, fault detection and diagnosis. October. Finland: Technical Research Center of Finland, Laboratory of Heating and Ventilation, B. 0. Box 206 (Lampomiehenkuja 3) 02150 ESPOO. Kaler. G. 1988. Expert system...

Watt, J. B.; O'Neal, D. L.; Haberl, J. S.

1998-01-01T23:59:59.000Z

412

Avoiding 100 new power plants by increasing efficiency of room air conditioners in India: opportunities and challenges  

SciTech Connect (OSTI)

Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40% cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

Phadke, Amol; Abhyankar, Nikit; Shah, Nihar; [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

2013-10-15T23:59:59.000Z

413

PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976  

E-Print Network [OSTI]

solar collectors almost certainly reqld res evaporat 1ve coo 1 i ng towers,tower for water- cooling the condenser was an overriding concern in development of a practical solar

Dao, K.

2010-01-01T23:59:59.000Z

414

NREL Demonstrates Game-Changing Air Conditioner Technology (Fact Sheet), Highlights in Research & Development, NREL (National Renewable Energy Laboratory)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas Conchas recoveryLaboratory | National Nuclearover two yearsNP UserReportTesting of DEVAP

415

NREL Solves Residential Window Air Conditioner Performance Limitations (Fact Sheet), Highlights in Research & Development, NREL (National Renewable Energy Laboratory)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas Conchas recoveryLaboratory | National Nuclearover two yearsNPResults giveSimulator fOr Wind13

416

An Evaluation of the Effects of Refrigerant Charge on a Residential Central Air Conditioner with Orifice Expansion  

E-Print Network [OSTI]

had one row of tubes with spine fins spaced at 20 per inch. The face area of the coil was 20.94 ft with refrigerant tube sizes of 3/8". The outdoor fan was located on the top of the outdoor coil. The fan specifications are given in Table 2.... 2.5 Table 2.1 - Fan Specification Refrigerant Side A schematic of the refrigerant circuit is shown in Figure 2.3. Refrigerant pressures were monitored at the 6 points shown with the use of 0-300 psig pressure transducers. To accurately measure...

O'Neal, D. L.; Ramsey, C. J.; Farzad, M.

1989-01-01T23:59:59.000Z

417

PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976  

E-Print Network [OSTI]

U. THW . In T HW out TSS Q UW (Btu/hr) LiT m U IllWS (Ibs/OF) (OF) (OF) (OF) (OF) (Btu/hr ft2.F 20A 20C 19A lIS 17BU Run number m HW (1bs/hr) (Btu/hr- ft2_F) mS == ! z(nlWS+

Dao, K.

2010-01-01T23:59:59.000Z

418

Modeling VOC sorption of building materials and its impact on indoor air quality  

E-Print Network [OSTI]

Sorption of volatile organic compounds (VOCs) by building materials can have significant effect on the indoor VOC concentration levels and indoor air quality in buildings. The objective of this study was to investigate ...

Zhang, Jinsong, 1975-

2001-01-01T23:59:59.000Z

419

A response surface model of the air quality impacts of aviation  

E-Print Network [OSTI]

Aviation demand is expected to double in the coming decades, and there are growing concerns about its impacts on the environment. Governments seek to mitigate the impacts of aviation on climate, air quality, and noise by ...

Ma?ek, Tudor

2008-01-01T23:59:59.000Z

420

E-Print Network 3.0 - air box model Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

gas-phase photochemistry and with plume... on the rate and on the mass of ambient air entrainment into the plume are studied also by com- paring the box... ). These...

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Transitions of cloud-topped marine boundary layers characterized by AIRS, MODIS, and a large eddy simulation model  

SciTech Connect (OSTI)

Cloud top entrainment instability (CTEI) is a hypothesized positive feedback between entrainment mixing and evaporative cooling near the cloud top. Previous theoretical and numerical modeling studies have shown that the persistence or breakup of marine boundary layer (MBL) clouds may be sensitive to the CTEI parameter. Collocated thermodynamic profile and cloud observations obtained from the Atmospheric Infrared Sounder (AIRS) and Moderate Resolution Imaging Spectroradiometer (MODIS) instruments are used to quantify the relationship between the CTEI parameter and the cloud-topped MBL transition from stratocumulus to trade cumulus in the northeastern Pacific Ocean. Results derived from AIRS and MODIS are compared with numerical results from the UCLA large eddy simulation (LES) model for both well-mixed and decoupled MBLs. The satellite and model results both demonstrate a clear correlation between the CTEI parameter and MBL cloud fraction. Despite fundamental differences between LES steady state results and the instantaneous snapshot type of observations from satellites, significant correlations for both the instantaneous pixel-scale observations and the long-term averaged spatial patterns between the CTEI parameter and MBL cloud fraction are found from the satellite observations and are consistent with LES results. This suggests the potential of using AIRS and MODIS to quantify global and temporal characteristics of the cloud-topped MBL transition.

Yue, Qing; Kahn, Brian; Xiao, Heng; Schreier, Mathias; Fetzer, E. J.; Teixeira, J.; Suselj, Kay

2013-08-16T23:59:59.000Z

422

Exploring the concept of compressed air energy storage (CAES) in lined rock caverns at shallow depth: A modeling study of air tightness and energy balance  

E-Print Network [OSTI]

Progress in electrical energy storage system: a criticalcurrent and future energy storage technologies for electricwind- diesel-compressed air energy storage system for remote

Kim, H.-M.

2012-01-01T23:59:59.000Z

423

SPECIAL ANALYSIS AIR PATHWAY MODELING OF E-AREA LOW-LEVEL WASTE FACILITY  

SciTech Connect (OSTI)

This Special Analysis (SA) was initiated to address a concern expressed by the Department of Energy's Low Level Waste Disposal Facility Federal Review Group (LFRG) Review Team during their review of the 2008 E-Area Performance Assessment (PA) (WSRC, 2008). Their concern was the potential for overlapping of atmospheric plumes, emanating from the soil surface above SRS LLW disposal facilities within the E-Area, to contribute to the dose received by a member of the public during the Institutional Control (IC) period. The implication of this concern was that the dose to the maximally-exposed individual (MEI) located at the SRS boundary might be underestimated during this time interval. To address this concern a re-analysis of the atmospheric pathway releases from E-Area was required. In the process of developing a new atmospheric release model (ARM) capable of addressing the LFRG plume overlap concern, it became obvious that new and better atmospheric pathway disposal limits should be developed for each of the E-Area disposal facilities using the new ARM. The scope of the SA was therefore expanded to include the generation of these new limits. The initial work conducted in this SA was to develop a new ARM using the GoldSim{reg_sign} program (GTG, 2009). The model simulates the subsurface vapor diffusion of volatile radionuclides as they release from E-Area disposal facility waste zones and migrate to the land surface. In the process of this work, many new features, including several new physical and chemical transport mechanisms, were incorporated into the model. One of the most important improvements was to incorporate a mechanism to partition volatile contaminants across the water-air interface within the partially saturated pore space of the engineered and natural materials through which vapor phase transport occurs. A second mechanism that was equally important was to incorporate a maximum concentration of 1.9E-07 Ci/m{sup 3} of {sup 14}CO{sub 2} in the air-filled pores of cementitious materials. The ARM also combines the individual transport models constructed for each E-Area disposal facility into a single model, and was ultimately used to analyze the LFRG concern regarding the potential for atmospheric plume overlap at the SRS boundary during the IC period. To evaluate the plume overlap issue, a conservative approach was adopted whereby the MEI at the SRS boundary was exposed to the releases from all E-Area disposal facilities simultaneously. This is equivalent to a 100% overlap of all atmospheric plumes emanating from E-Area. Should the dose received from this level of atmospheric plume overlap still fall below the permissible exposure level of 10 mrem/yr, then the LFRG concern would be alleviated. The structuring of the ARM enables this evaluation to be easily performed. During the IC period, the peak of the 'total plume overlap dose' was computed to be 1.9E-05 mrem/yr, which is five orders of magnitude lower than the 10 mrem/yr PA performance objective for the atmospheric release pathway. The main conclusion of this study is that for atmospheric releases from the E-Area disposal facilities, plume overlap does not cause the total dose to the MEI at the SRS boundary during the IC to exceed the Performance Assessment (PA) performance objective. Additionally, the potential for plume overlap was assessed in the post-Institutional Control period. Atmospheric plume overlap is less likely to occur during this period but conceivably could occur if the prevailing wind direction shifted so as to pass directly over all EArea disposal facilities and transport airborne radionuclides to the MEI at the 100 m point of compliance (POC). This concern was also demonstrated of little concern, as the maximum plume overlap dose was found to be 1.45E+00 mrem/yr (or {approx}15% of the performance measure) during this period and under these unlikely conditions.

Hiergesell, R.; Taylor, G.

2011-08-30T23:59:59.000Z

424

Air Products effective way  

E-Print Network [OSTI]

PE O A e s a b O T A O ENNST Overview Air Products effective way standard me Departm Shipping has recently y of shipping eans. Air Pro ontainer that es of this pro onduct mark eep accelera eep the cost tilize widely a earch and m m visited Air er needs wer model was cr m approache ms

Demirel, Melik C.

425

Air Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Why Air Quality Air Quality To preserve our existing wilderness-area air quality, LANL implements a conscientious program of air monitoring. April 12, 2012 Real-time data...

426

Competitive allocation of resources on a network: an agent-based model of air companies competing for the best routes  

E-Print Network [OSTI]

We present a stylized model of the allocation of resources on a network. By considering as a concrete example the network of sectors of the airspace, where each node is a sector characterized by a maximal number of simultaneously present aircraft, we consider the problem of air companies competing for the allocation of the airspace. Each company is characterized by a cost function, weighting differently punctuality and length of the flight. We consider the model in the presence of pure and mixed populations of types of airline companies and we study how the equilibria depends on the characteristics of the network.

Gurtner, Gérald; Lillo, Fabrizio

2014-01-01T23:59:59.000Z

427

Development of an equivalent homogenous fluid model for pseudo-two-phase (air plus water) flow through fractured rock  

SciTech Connect (OSTI)

Fracture flow of two-phase mixtures is particularly applicable to the coal mining and coal bed methane projects in Australia. A one-dimensional steady-state pseudo-two-phase flow model is proposed for fractured rock. The model considers free flow of a compressible mixture of air and water in an inclined planar fracture and is based upon the conservation of momentum and the 'cubic' law. The flow model is coupled to changes in the stress environment through the fracture normal stiffness, which is related to changes in fracture aperture. The model represents the individual air and water phases as a single equivalent homogenous fluid. Laboratory testing was performed using the two-phase high-pressure triaxial apparatus on 54 mm diameter (approximately 2: 1 height: diameter) borehole cores intersected by induced near-axial fractures. The samples were of Triassic arenaceous fine-medium grained sandstone (known as the Eckersley Formation) that is found locally in the Southern Coalfield of New South Wales. The sample fracture roughness was assessed using a technique based upon Fourier series analysis to objectively attribute a joint roughness coefficient. The proposed two-phase flow model was verified using the recorded laboratory data obtained over a range of triaxial confining pressures (i.e., fracture normal stresses).

Price, J.; Indraratna, B. [University of Wollongong, Wollongong, NSW (Australia). School of Civil Engineering

2005-07-01T23:59:59.000Z

428

Towards the modeling of mucus draining from human lung: role of airways deformation on air-mucus interaction  

E-Print Network [OSTI]

Chest physiotherapy is an empirical technique used to help secretions to get out of the lung whenever stagnation occurs. Although commonly used, little is known about the inner mechanisms of chest physiotherapy and controversies about its use are coming out regularly. Thus, a scientific validation of chest physiotherapy is needed to evaluate its effects on secretions. We setup a quasi-static numerical model of chest physiotherapy based on thorax and lung physiology and on their respective biophysics. We modeled the lung with an idealized deformable symmetric bifurcating tree. Bronchi and their inner fluids mechanics are assumed axisymmetric. Static data from the literature is used to build a model for the lung's mechanics. Secretions motion is the consequence of the shear constraints apply by the air flow. The input of the model is the pressure on the chest wall at each time, and the output is the bronchi geometry and air and secretions properties. In the limit of our model, we mimicked manual and mechanical ...

Mauroy, Benjamin; Pelca, Dominique; Fausser, Christian; Merckx, Jacques; Mitchell, Barrett R

2015-01-01T23:59:59.000Z

429

Modeling the Transport and Chemical Evolution of Onshore and Offshore Emissions and their Impact on Local and Regional Air Quality Using a Variable-Grid-Resolution Air Quality Model  

SciTech Connect (OSTI)

This Annual report summarizes the research performed from 17 April 2005 through 16 April 2006. Major portions of the research in several of the project's current eight tasks have been completed. We have successfully developed the meteorological inputs using the best possible modeling configurations, resulting in improved representation of atmospheric processes. The development of the variable-grid-resolution emissions model, SMOKE-VGR, is also completed. The development of the MAQSIP-VGR has been completed and a test run was performed to ensure the functionality of this air quality model. We have incorporated new emission data base to update the offshore emissions. However, we have faced some bottleneck problems in the testing the integrity of the new database. For this reason, we have asked for a no cost extension of this project to tackle these scientific problems. Thus, the project is on a one-year delay schedule. During the reporting period, we solved all problems related to the new emission database. We are ready to move to developing the final product, implementation and testing of the variable grid technology into the Community Multiscale Air Quality Model (CMAQ) to develop the CMAQ-VGR. During the upcoming months we will perform the first CMAQ-VGR simulations over the Houston-Galveston region to study the roles of the meteorology, offshore emissions, and chemistry-transport interactions that determine the temporal and spatial evolution of ozone and its precursors.

Kiran Alapaty

2006-04-16T23:59:59.000Z

430

A lightning summary and decision model for thunderstorm prediction at Whiteman Air Force Base, Missouri  

E-Print Network [OSTI]

A cloud-to-ground lightning summary was developed for a 139xl85 kilometer area centered at Whiteman Air Force Base. Spatial and temporal patterns, and first stroke peak currents were analyzed from 1989-1995. Stability indices were examined...

Bass, Randall Gerald

1996-01-01T23:59:59.000Z

431

Model-based control strategies in the dynamic interaction of air supply and fuel cell  

E-Print Network [OSTI]

be successfully maintained through feedforward control of the air compressor motor voltage. However, the net power compressor motor related quantity Cp compressor related quantity d downstream quantity des desired level2 hydrogen related quantity in inlet quantity m membrane related quantity net net quantity N2

Grujicic, Mica

432

Model Based Sensor System for Temperature Measurement in R744 Air Conditioning Systems  

E-Print Network [OSTI]

The goal is the development of a novel principle for the temperature acquisition of refrigerants in CO2 air conditioning systems. The new approach is based on measuring the temperature inside a pressure sensor, which is also needed in the system. On the basis of simulative investigations of different mounting conditions functional relations between measured and medium temperature will be derived.

Reitz, Sven; Schneider, Peter

2008-01-01T23:59:59.000Z

433

Predictive clothing insulation model based on outdoor air and indoor operative temperatures  

E-Print Network [OSTI]

2012) Predictive clothing insulation model based on outdoorPredictive clothing insulation model based on outdoor airpredictive models of clothing insulation have been developed

Schiavon, Stefano; Lee, Kwang Ho

2012-01-01T23:59:59.000Z

434

MODELING THE TRANSPORT AND CHEMICAL EVOLUTION OF ONSHORE AND OFFSHORE EMISSIONS AND THEIR IMPACT ON LOCAL AND REGIONAL AIR QUALITY USING A VARIABLE-GRID-RESOLUTION AIR QUALITY MODEL  

SciTech Connect (OSTI)

This second annual report summarizes the research performed from 17 April 2004 through 16 April 2005. Major portions of the research in several of the project's current eight tasks have been completed. We have successfully developed the meteorological inputs using the best possible modeling configurations, resulting in improved representation of atmospheric processes. The development of the variable-grid-resolution emissions model, SMOKE-VGR, is also completed. The development of the MAQSIP-VGR has been completed and a test run was performed to ensure the functionality of this air quality model. Thus, the project is on schedule as planned. During the upcoming reporting period, we expect to perform the first MAQSIP-VGR simulations over the Houston-Galveston region to study the roles of the meteorology, offshore emissions, and chemistry-transport interactions that determine the temporal and spatial evolution of ozone and its precursors.

Kiran Alapaty

2005-05-13T23:59:59.000Z

435

Calendar Year 2007 Program Benefits for U.S. EPA Energy Star Labeled Products: Expanded Methodology  

E-Print Network [OSTI]

Air Conditioners and Air Source Heat Pumps. Unpublishedpackage central air conditioners and heat pumps, rated atManufacturers air source heat pump American Society of

Sanchez, Marla

2010-01-01T23:59:59.000Z

436

Exploring the concept of compressed air energy storage (CAES) in lined rock caverns at shallow depth: A modeling study of air tightness and energy balance  

E-Print Network [OSTI]

Calculated time integrated energy balance term in the 5 thCalculated time integrated energy balance term in the 5 thof air tightness and energy balance Hyung-Mok Kim 1 , Jonny

Kim, H.-M.

2012-01-01T23:59:59.000Z

437

Clean Air Interstate Rule: Changes and Modeling in AEO2010 (released in AEO2010)  

Reports and Publications (EIA)

On December 23, 2008, the D.C. Circuit Court remanded but did not vacate the Clean Air Interstate Rule (CAIR), overriding its previous decision on February 8, 2008, to remand and vacate CAIR. The December decision, which is reflected in Annual Energy Outlook 2010 (AEO) , allows CAIR to remain in effect, providing time for the Environmental Protection Agency to modify the rule in order to address objections raised by the Court in its earlier decision. A similar rule, referred to as the Clean Air Mercury Rule (CAMR), which was to set up a cap-and-trade system for reducing mercury emissions by approximately 70%, is not represented in the AEO2010 projections, because it was vacated by the D.C. Circuit Court in February 2008.

2010-01-01T23:59:59.000Z

438

Numerical models analysis of energy conversion process in air-breathing laser propulsion  

SciTech Connect (OSTI)

Energy source was considered as a key essential in this paper to describe energy conversion process in air-breathing laser propulsion. Some secondary factors were ignored when three independent modules, ray transmission module, energy source term module and fluid dynamic module, were established by simultaneous laser radiation transportation equation and fluid mechanics equation. The incidence laser beam was simulated based on ray tracing method. The calculated results were in good agreement with those of theoretical analysis and experiments.

Hong Yanji; Song Junling; Cui Cunyan; Li Qian [Academy of Equipment Command and Technology, 101416 Beijing (China)

2011-11-10T23:59:59.000Z

439

AIR AND RADON PATHWAY MODELING FOR THE F AREA TANK FARM  

SciTech Connect (OSTI)

An air and radon pathways analysis was conducted for the F-Area Tank Farm (FTF) to estimate the flux of volatile radionuclides and radon at the ground surface due to residual waste remaining in the tanks following closure. This analysis was used as the basis to estimate the dose to the maximally exposed individual (MEI) for the air pathway per Curie (Ci) of each radionuclide remaining in the combined FTF waste tanks. For the air pathway analysis, several gaseous radionuclides were considered. These included carbon-14 (C-14), chlorine-36 (Cl-36), iodine-129 (I-129), selenium-79 (Se-79), antimony-125 (Sb-125), tin-126 (Sn-126), tritium (H-3), and technetium-99 (Tc-99). The dose to the MEI was estimated at the SRS Boundary during the 100 year institutional control period. For the 10,000 year post closure compliance period, the dose to the MEI was estimated at the 100 m compliance point. Additionally, the dose to the MEI was estimated at a seepage outcrop located 1600 m from the facility. For the radon pathway analysis, five parent radionuclides and their progeny were analyzed. These parent radionuclides included uranium-238 (U-238), plutonium-238 (Pu-238), uranium-234 (U-234), thorium-230 (Th-230), and radium-226 (Ra-226). The peak flux of radon-222 due to each parent radionuclide was estimated for the simulation period of 10,100 years.

Dixon, K.; Phifer, M.

2010-07-30T23:59:59.000Z

440

Modeling Improvements for Air Source Heat Pumps using Different Expansion Devices at Varied Charge Levels Part II  

SciTech Connect (OSTI)

This paper describes steady-state performance simulations performed on a 3-ton R-22 split heat pump in heating mode. In total, 150 steady-state points were simulated, which covers refrigerant charge levels from 70 % to 130% relative to the nominal value, the outdoor temperatures at 17 F (-8.3 C), 35 F (1.7 C) and 47 F (8.3 C), indoor air flow rates from 60% to 150% of the rated air flow rate, and two types of expansion devices (fixed orifice and thermostatic expansion valve). A charge tuning method, which is to calibrate the charge inventory model based on measurements at two operation conditions, was applied and shown to improve the system simulation accuracy significantly in an extensive range of charge levels. In addition, we discuss the effects of suction line accumulator in modeling a heat pump system using either a fixed orifice or thermal expansion valve. Last, we identify the issue of refrigerant mass flow mal-distribution at low charge levels and propose an improved modeling approach.

Shen, Bo [ORNL

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Analysis of an open-air swimming pool solar heating system by using an experimentally validated TRNSYS model  

SciTech Connect (OSTI)

In the case of private outdoor swimming pools, seldom larger than 100 m{sup 2}, conventional auxiliary heating systems are being installed less and less. Solar heating is an option to extend the swimming season. The temperature evolution of an open-air swimming pool highly depends on the wind speed directly on the water surface, which at the same time is influenced by the surroundings of the pool. In this paper, the TRNSYS model of a private open-air pool with a 50-m{sup 2} surface was validated by registering the water temperature evolution and the meteorological data at the pool site. Evaporation is the main component of energy loss in swimming pools. Six different sets of constants found in literature were considered to evaluate the evaporative heat transfer coefficient with the purpose of finding the most suitable one for the TRNSYS pool model. In order to do that, the evolution of the pool water temperature predicted by the TRNSYS pool model was compared with the experimentally registered one. The simulation with TRNSYS of the total system, including the swimming pool and the absorber circuit integrated into the existing filter circuit, provided information regarding the increase of the pool temperature for different collector areas during the swimming season. This knowledge, together with the economic costs, support the decision about the absorber field size. (author)

Ruiz, Elisa; Martinez, Pedro J. [Universidad Miguel Hernandez - Edificio Torreblanca, Avda. de la Universidad s/n, 03202 Elche (Spain)

2010-01-15T23:59:59.000Z

442

PESC'99, Charleston, South Carolina, June 27 July 1, pp. 393-399. A Multilevel Converter-Based Universal Power Conditioner  

E-Print Network [OSTI]

, and reactive power compensation. Level usage in the series inverter and parallel inverter is analyzed that the customer can impose on the utility. To meet the objectives detailed in these new premium power agreements- clamped inverter into a universal power conditioner is an enticing prospect. A multilevel universal power

Tolbert, Leon M.

443

Description and preliminary validation of a model for natural convection heat and air transport in passive solar buildings  

SciTech Connect (OSTI)

We have proposed a transient, quasi-two-dimensional, numerical model for interzone heat flow and airflow in passive solar buildings. The paths for heat flow and airflow are through connecting apertures such as doorways, hallways, and stairways. The model includes the major features that influence interzone convection as determined from the results of our flow visualization tests and temperature and airflow measurements taken in more than a dozen passive solar buildings. The model includes laminar and turbulent quasi-steady boundary-layer equations at vertical heated or cooled walls which are coupled to a one-dimensional core model for each zone. The cores in each zone exchange air and energy through the aperture which is modelled by a Bernoulli equation. Preliminary results from the model are in general agreement with data obtained in full-scale buildings and laboratory experiments. The model predicts room-core temperature stratification of about 2/sup 0/C/m (1.1/sup 0/ F/ft) and maximum aperture velocities of 0.08 m/s (15 ft/min.) for a room-to-room temperature difference of 1/sup 0/F.

Jones, G.F.; Balcomb, J.D.

1985-01-01T23:59:59.000Z

444

Air Monitoring Modeling of Radioactive Releases During Proposed PFP Complex Demolition Activities  

SciTech Connect (OSTI)

This report is part of the planning process for the demolition of the 234-5Z, 236-Z, 242-Z, and 291-Z-1 structures at the Plutonium Finishing Plant (PFP) facilities on the Hanford Site. Pacific Northwest National Laboratory (PNNL) supports the U.S. Department of Energy (DOE) and the CH2M HILL Plateau Remediation Company (CHPRC) demolition planning effort by making engineering estimates of potential releases for various potential demolition alternatives. This report documents an analysis considering open-air demolition using standard techniques. It does not document any decisions about the decommissioning approaches; it is expected that this report will be revisited as demolition plans are finalized.

Napier, Bruce A.; Droppo, James G.; Rishel, Jeremy P.

2011-01-24T23:59:59.000Z

445

Ensemble operational air quality assessments in Europe Improving modeling platforms with statistical analysis  

E-Print Network [OSTI]

with statistical analysis Anthony Ung, Laure Malherbe, Frederik Meleux, Bertrand Bessagnet, Laurence Rouil and MACCII modeling team INERIS institut, Paris, France Corresponding author: Anthony.ung@ineris.fr Abstract/QC dossiers and available on the MACC project website for each model. All models have also very significant

Paris-Sud XI, Université de

446

AIR AND RADON PATHWAY MODELING FOR THE F-AREA TANK FARM  

SciTech Connect (OSTI)

The F-Area Tank Farm (FTF) is located within F-Area in the General Separations Area (GSA) of the Savannah River Site (SRS) as seen in Figure 1. The GSA contains the F and H Area Separations Facilities, the S-Area Defense Waste Processing Facility, the Z-Area Saltstone Facility, and the E-Area Low-Level Waste Disposal Facilities. The FTF is a nearly rectangular shaped area and comprises approximately 20 acres, which is bounded by SRS coordinates N 76,604.5 to N 77,560.0 and E 52,435.0 to E 53,369.0. SRS is in the process of preparing a Performance Assessment (PA) to support FTF closure. As part of the PA process, an analysis was conducted to evaluate the potential magnitude of gaseous release of radionuclides from the FTF over the 100-year institutional control period and 10,000-year post-closure compliance period. Specifically, an air and radon pathways analysis has been conducted to estimate the flux of volatile radionuclides and radon at the ground surface due to residual waste remaining in the tanks following closure. This analysis was used as the basis to estimate the dose to the maximally exposed individual (MEI) for the air pathway per Curie (Ci) of each radionuclide remaining in the combined FTF waste tanks. For the air pathway analysis, several gaseous radionuclides were considered. These included carbon-14 (C-14), chlorine-36 (Cl-36), iodine-129 (I-129), selenium-79 (Se-79), antimony-125 (Sb-125), tin-126 (Sn-126), tritium (H-3), and technetium-99 (Tc-99). The dose to the MEI was estimated at the SRS Boundary during the 100 year institutional control period. For the 10,000 year post closure compliance period, the dose to the MEI was estimated at the 100 m compliance point. For the radon pathway analysis, five parent radionuclides and their progeny were analyzed. These parent radionuclides included uranium-238 (U-238), plutonium-238 (Pu-238), uranium-234 (U-234), thorium-230 (Th-230), and radium-226 (Ra-226). The peak flux of radon-222 due to each parent radionuclide was estimated for the simulation period of 10,100 years.

Dixon, K; Mark Phifer, M

2007-09-17T23:59:59.000Z

447

Environmental Pollution Air Pollution Dispersion Practical Air Pollution Dispersion  

E-Print Network [OSTI]

Environmental Pollution Air Pollution Dispersion 1 of 5 Practical ­ Air Pollution Dispersion in the lectures how such models can be used to explain observed concentrations of air pollutants in an area and to test `what-if' scenarios for pollution control and reduction. You will use the Gaussian Plume Model

Moncrieff, John B.

448

Air Dispersion Modeling of Radioactive Releases During Proposed PFP Complex Demolition Activities  

SciTech Connect (OSTI)

This report is part of the planning process for the demolition of the 234-5Z, 236-Z, 242-Z, and 291-Z-1 structures at the Plutonium Finishing Plant (PFP) on the Hanford Site. Pacific Northwest National Laboratory (PNNL) supports the U.S. Department of Energy (DOE) and the CH2M HILL Plateau Remediation Company (CHPRC) demolition planning effort by making engineering estimates of potential releases for various potential demolition alternatives. This report documents an analysis considering open-air demolition using standard techniques. It does not document any decisions about the decommissioning approaches; it is expected that this report will be revisited as the final details of the demolition are developed.

Napier, Bruce A.; Droppo, James G.; Rishel, Jeremy P.

2011-01-11T23:59:59.000Z

449

Paper presented at the 4th International Conference Working on Safety, Crete, Greece, 2008 Functional modeling for risk assessment of automation in a changing air  

E-Print Network [OSTI]

Functional modeling for risk assessment of automation in a changing air traffic management environment R or to let automation act autonomously. The Functional Resonance Analysis Method (FRAM) provides a framework from ERASMUS automation. Various instantiations of a partial model resulting from the application

Zhao, Yuxiao

450

IEEE TRANSACTIONS ON AUTOMATIC CONTROL, VOL. 43, NO. 4, APRIL 1998 457 Guest Editorial  

E-Print Network [OSTI]

control the furnace, air conditioner, blower, etc. There are several reasons for using hybrid models hybrid control system is the heating and cooling system of a typical home. The furnace and air conditioner, along with the heat flow characteristics of the home, form a continuous-time system which

Antsaklis, Panos

451

Dynamic predictive clothing insulation models based on outdoor air and indoor operative temperatures  

E-Print Network [OSTI]

predictive clothing insulation models based on outdoor airrange of the clothing insulation calculated for eachbuilding). Figure 8 Clothing insulation versus dress code [

Schiavon, Stefano; Lee, Kwang Ho

2012-01-01T23:59:59.000Z

452

Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1  

E-Print Network [OSTI]

A H A M . 1991. Room Air Conditioner Data. Association of7. FUTURE WORK 7.1 Room Air Conditioners 7.2. Common heatingShipments of Unitary Air Conditioners and Heat Pumps. Air-

Johnson, F.X.

2010-01-01T23:59:59.000Z

453

Energy Consumption, Efficiency, Conservation, and Greenhouse Gas Mitigation in Japan's Building Sector  

E-Print Network [OSTI]

4.4.3 C o o l i n g Air Conditioner Multi-room Load AirGHPs) Chillers Air Conditioner COP Desiccant Conditioningappliances such as air-conditioners, refrigerators and

2006-01-01T23:59:59.000Z

454

Comparing zonal and CFD models of air flows in large indoor spaces to experimental data  

E-Print Network [OSTI]

A.l Mass airflow rates obtained with SD-SDF model (in g-sLaw mod­ els with Specific Driven Flows, or PL-SDF mod­ els.In the PL-SDF class of models, Bouia de­ veloped an

Mora, L.

2011-01-01T23:59:59.000Z

455

Modeling the pneumatic relay valve of an s-cam air brake  

E-Print Network [OSTI]

- niques. The design of a model-based diagnostic system requires the development and experimental corroboration of a mathematical model of the evolution of pressure in each brake chamber of a truck in response to the application of brake pedal input...

Vilayannur Natarajan, Shankar

2005-08-29T23:59:59.000Z

456

Modeling the Transport and Chemical Evolution of Onshore and Offshore Emissions and their Impact on Local and Regional Air Quality Using a Variable-Grid-Resolution Air Quality Model  

SciTech Connect (OSTI)

This semiannual report summarizes the research performed from 17 April through 16 October 2004. Major portions of the research in several of the project's current eight tasks have been completed, and the results obtained are briefly presented. We have successfully developed the meteorological inputs using the best possible modeling configurations, resulting in improved representation of atmospheric processes. Ingestion of satellite-derived sea surface temperatures in conjunction with the use of our new surface data assimilation technique have resulted in largely improved meteorological inputs to drive the MAQSIP-VGR. The development of the variable-grid-resolution emissions model, SMOKE-VGR, is also largely complete. We expect to develop the final configuration of the SMOKE-VGR during the upcoming reporting period. We are in the process of acquiring the newly released emissions database and offshore emissions data sets to update our archives. The development of the MAQSIP-VGR has been completed and a test run was performed to ensure the functionality of this air quality model. During the upcoming reporting period, we expect to perform the first MAQSIP-VGR simulations over the Houston-Galveston region to study the roles of the meteorology, offshore emissions, and chemistry-transport interactions that determine the temporal and spatial evolution of ozone and its precursors.

Kiran Alapaty

2004-10-16T23:59:59.000Z

457

Energy Blog | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

single room air conditioners, water heathers, central air conditioners, air-source heat pumps, furnaces and ground-source heat pumps. August 27, 2010 New LED lighting...

458

Realized and Projected Impacts of U.S. Energy Efficiency Standards for Residential and Commercial Appliances  

E-Print Network [OSTI]

Standards for Consumer Products: Room Air Conditioners,Energy Savings -- Residential Products Room Air Conditionersfor Consumer Products: Residential Central Air Conditioners

Meyers, Stephen P.

2008-01-01T23:59:59.000Z

459

Assessment of the Impacts of Standards and Labeling Programs in Mexico (four products).  

E-Print Network [OSTI]

Level Trends – Air Conditioner Product Classes Product Class7 – Efficiency of Air Conditioner Product Classes (Watts/for four major products: household refrigerators, room air

Sanchez, Itha; Pulido, Henry; McNeil, Michael A.; Turiel, Isaac; della Cava, Mirka

2007-01-01T23:59:59.000Z

460

Compliance and Verification of Standards and Labelling Programs in China: Lessons Learned  

E-Print Network [OSTI]

for household refrigerators/ freezers and room airZhou et al 2008] Refrigerators Freezers Air conditionersZhou et al 2008] Refrigerators Freezers Air conditioners

Saheb, Yamina

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Compliance and Verification of Standards and Labeling Programs in China: Lessons Learned  

E-Print Network [OSTI]

for household refrigerators/ freezers and room airZhou et al 2008] Refrigerators Freezers Air conditionersZhou et al 2008] Refrigerators Freezers Air conditioners

Saheb, Yamina

2011-01-01T23:59:59.000Z

462

Calendar Year 2009 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network [OSTI]

covers central air conditioners and heat pumps with up toconditioning, ASHP = air source heat pump, HP = heat pump,Conditioners and Air-Source Heat Pumps • Commercial Fryers •

Homan, Gregory K

2011-01-01T23:59:59.000Z

463

Calendar Year 2008 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network [OSTI]

covers central air conditioners and heat pumps with up toconditioning, ASHP = air source heat pump, HP = heat pump,Conditioners and Air-Source Heat Pumps • Commercial Fryers •

Homan, GregoryK

2010-01-01T23:59:59.000Z

464

Using a chemistry transport model to account for the spatial variability of exposure-concentrations in epidemiologic air  

E-Print Network [OSTI]

as exposure surrogates in time-series studies of the association between ambient air pollution and health surrogates for use in time-series studies of air pollution short-term health effects. Pollutant-concentrations in epidemiologic air pollution studies Myrto Valari and Laurent Menut Laboratoire de Météorologie Dynamique

Menut, Laurent

465

Modeling and Control of Aggregated Air Conditioning Loads Under Realistic Conditions  

SciTech Connect (OSTI)

Demand-side control is playing an increasingly important role in smart grid control strategies. Modeling the dynamical behavior of a large population of appliances is especially important to evaluate the effectiveness of various load control strategies. In this paper, a high accuracy aggregated model is first developed for a population of HVAC units. The model efficiently includes statistical information of the population, systematically deals with heterogeneity, and accounts for a second-order effect necessary to accurately capture the transient dynamics in the collective response. Furthermore, the model takes into account the lockout effect of the compressor in order to represent the dynamics of the system under control more accurately. Then, a novel closed loop load control strategy is designed to track a desired demand curve and to ensure a stable and smooth response.

Chang, Chin-Yao; Zhang, Wei; Lian, Jianming; Kalsi, Karanjit

2013-02-24T23:59:59.000Z

466

Air pollution forecasting by coupled atmosphere-fire model WRF and SFIRE with WRF-Chem  

E-Print Network [OSTI]

Atmospheric pollution regulations have emerged as a dominant obstacle to prescribed burns. Thus, forecasting the pollution caused by wildland fires has acquired high importance. WRF and SFIRE model wildland fire spread in a two-way interaction with the atmosphere. The surface heat flux from the fire causes strong updrafts, which in turn change the winds and affect the fire spread. Fire emissions, estimated from the burning organic matter, are inserted in every time step into WRF-Chem tracers at the lowest atmospheric layer. The buoyancy caused by the fire then naturally simulates plume dynamics, and the chemical transport in WRF-Chem provides a forecast of the pollution spread. We discuss the choice of wood burning models and compatible chemical transport models in WRF-Chem, and demonstrate the results on case studies.

Kochanski, Adam K; Mandel, Jan; Clements, Craig B

2013-01-01T23:59:59.000Z

467

Development of models for series and parallel fan variable air volume terminal units  

E-Print Network [OSTI]

for the series and parallel units, with coefficients varying by size and manufacturer. Statistical modeling utilized SAS software (2002). Fan power and airflow data were collected at downstream static pressures over a range from 0.1 to 0.5 in. w.g. (25 to 125 Pa...

Furr, James C., Jr

2007-09-17T23:59:59.000Z

468

Improved Formulations for Air-Surface Exchanges Related to National Security Needs: Dry Deposition Models  

SciTech Connect (OSTI)

The Department of Homeland Security and others rely on results from atmospheric dispersion models for threat evaluation, event management, and post-event analyses. The ability to simulate dry deposition rates is a crucial part of our emergency preparedness capabilities. Deposited materials pose potential hazards from radioactive shine, inhalation, and ingestion pathways. A reliable characterization of these potential exposures is critical for management and mitigation of these hazards. A review of the current status of dry deposition formulations used in these atmospheric dispersion models was conducted. The formulations for dry deposition of particulate materials from am event such as a radiological attack involving a Radiological Detonation Device (RDD) is considered. The results of this effort are applicable to current emergency preparedness capabilities such as are deployed in the Interagency Modeling and Atmospheric Assessment Center (IMAAC), other similar national/regional emergency response systems, and standalone emergency response models. The review concludes that dry deposition formulations need to consider the full range of particle sizes including: 1) the accumulation mode range (0.1 to 1 micron diameter) and its minimum in deposition velocity, 2) smaller particles (less than .01 micron diameter) deposited mainly by molecular diffusion, 3) 10 to 50 micron diameter particles deposited mainly by impaction and gravitational settling, and 4) larger particles (greater than 100 micron diameter) deposited mainly by gravitational settling. The effects of the local turbulence intensity, particle characteristics, and surface element properties must also be addressed in the formulations. Specific areas for improvements in the dry deposition formulations are 1) capability of simulating near-field dry deposition patterns, 2) capability of addressing the full range of potential particle properties, 3) incorporation of particle surface retention/rebound processes, and. 4) development of dry deposition formulations applicable to urban areas. Also to improve dry deposition modeling capabilities, atmospheric dispersion models in which the dry deposition formulations are imbedded need better source-term plume initialization and improved in-plume treatment of particle growth processes. Dry deposition formulations used in current models are largely inapplicable to the complex urban environment. An improved capability is urgently needed to provide surface-specific information to assess local exposure hazard levels in both urban and non-urban areas on roads, buildings, crops, rivers, etc. A model improvement plan is developed with a near-term and far-term component. Despite some conceptual limitations, the current formulations for particle deposition based on a resistance approach have proven to provide reasonable dry deposition simulations. For many models with inadequate dry deposition formulations, adding or improving a resistance approach will be the desirable near-term update. Resistance models however are inapplicable aerodynamically very rough surfaces such as urban areas. In the longer term an improved parameterization of dry deposition needs to be developed that will be applicable to all surfaces, and in particular urban surfaces.

Droppo, James G.

2006-07-01T23:59:59.000Z

469

Comprehensive ecosystem model-experiment synthesis using multiple datasets at two temperate forest free-air CO2 enrichment experiments: model performance and compensating biases  

SciTech Connect (OSTI)

Free Air CO2 Enrichment (FACE) experiments provide a remarkable wealth of data to test the sensitivities of terrestrial ecosystem models (TEMs). In this study, a broad set of 11 TEMs were compared to 22 years of data from two contrasting FACE experiments in temperate forests of the south eastern US the evergreen Duke Forest and the deciduous Oak Ridge forest. We evaluated the models' ability to reproduce observed net primary productivity (NPP), transpiration and Leaf Area index (LAI) in ambient CO2 treatments. Encouragingly, many models simulated annual NPP and transpiration within observed uncertainty. Daily transpiration model errors were often related to errors in leaf area phenology and peak LAI. Our analysis demonstrates that the simulation of LAI often drives the simulation of transpiration and hence there is a need to adopt the most appropriate of hypothesis driven methods to simulate and predict LAI. Of the three competing hypotheses determining peak LAI (1) optimisation to maximise carbon export, (2) increasing SLA with canopy depth and (3) the pipe model the pipe model produced LAI closest to the observations. Modelled phenology was either prescribed or based on broader empirical calibrations to climate. In some cases, simulation accuracy was achieved through compensating biases in component variables. For example, NPP accuracy was sometimes achieved with counter-balancing biases in nitrogen use efficiency and nitrogen uptake. Combined analysis of parallel measurements aides the identification of offsetting biases; without which over-confidence in model abilities to predict ecosystem function may emerge, potentially leading to erroneous predictions of change under future climates.

Walker, Anthony P [ORNL] [ORNL; Hanson, Paul J [ORNL] [ORNL; DeKauwe, Martin G [Macquarie University] [Macquarie University; Medlyn, Belinda [Macquarie University] [Macquarie University; Zaehle, S [Max Planck Institute for Biogeochemistry] [Max Planck Institute for Biogeochemistry; Asao, Shinichi [Colorado State University, Fort Collins] [Colorado State University, Fort Collins; Dietze, Michael [University of Illinois, Urbana-Champaign] [University of Illinois, Urbana-Champaign; Hickler, Thomas [Goethe University, Frankfurt, Germany] [Goethe University, Frankfurt, Germany; Huntinford, Chris [Centre for Ecology and Hydrology, Wallingford, United Kingdom] [Centre for Ecology and Hydrology, Wallingford, United Kingdom; Iversen, Colleen M [ORNL] [ORNL; Jain, Atul [University of Illinois, Urbana-Champaign] [University of Illinois, Urbana-Champaign; Lomas, Mark [University of Sheffield] [University of Sheffield; Luo, Yiqi [University of Oklahoma] [University of Oklahoma; McCarthy, Heather R [Duke University] [Duke University; Parton, William [Colorado State University, Fort Collins] [Colorado State University, Fort Collins; Prentice, I. Collin [Macquarie University] [Macquarie University; Thornton, Peter E [ORNL] [ORNL; Wang, Shusen [Canada Centre for Remote Sensing (CCRS)] [Canada Centre for Remote Sensing (CCRS); Wang, Yingping [CSIRO Marine and Atmospheric Research] [CSIRO Marine and Atmospheric Research; Warlind, David [Lund University, Sweden] [Lund University, Sweden; Weng, Ensheng [University of Oklahoma, Norman] [University of Oklahoma, Norman; Warren, Jeffrey [ORNL] [ORNL; Woodward, F. Ian [University of Sheffield] [University of Sheffield; Oren, Ram [Duke University] [Duke University; Norby, Richard J [ORNL] [ORNL

2014-01-01T23:59:59.000Z

470

Residence Hall & Furnished  

E-Print Network [OSTI]

Air Conditioner Units . . . . . . . . . . . . . . . . . 7 Bunking/Lofting Beds & Air Conditioning . . . . . . . . . . . . 9 Mailing Address

Polly, David

471

TABLE OFCONTENTS Contract Information  

E-Print Network [OSTI]

....................................... 3 Your Room Assignments .......................................................... 4 Air Conditioner ................................................... 4 Consolidation ......................................................... 4 Heating &Air

Polly, David

472

A surface renewal model to analyze infrared image sequences of the ocean surface for the study of air-sea heat  

E-Print Network [OSTI]

A surface renewal model to analyze infrared image sequences of the ocean surface for the study of air-sea heat and gas exchange C. S. Garbe Interdisciplinary Center for Scientific Computing renewal, the net heat flux, and the heat transfer velocity during nighttime. The techniques are based

Garbe, Christoph S.

473

E-Print Network 3.0 - air temperature air Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

measured as 74 per of air flowing through the turbine. The turbine operates... the ideal gas model for air, determine the turbine efficiency. Problem 2 ... Source: Bahrami, Majid -...

474

Ignition of syngas/air and hydrogen/air mixtures at low temperatures and high pressures: Experimental data interpretation and kinetic modeling implications  

SciTech Connect (OSTI)

The magnitude of ignition delay observations and homogeneous kinetic calculations seen elsewhere is a result in large measure of departures of the experimental configurations from behavior dominated solely by homogeneous gas phase kinetics. In the regime of interest (higher pressures, lower temperatures), the hydrogen-oxygen chemical induction processes can be significantly perturbed by several nonhomogeneous effects, which include catalytic aberrations. The multiple perturbations that can significantly affect induction chemistry are very difficult to remove in research experiments and nearly impossible to control in engineering applications. The implications for developing lean premixing schemes for advanced syngas gas turbine applications are that designs must consider the inherent presence of these perturbations on ignition delay as well as those that might occur from potential particle contamination of the air stream exiting the compressor, if stimulated flashback into the mixing region is to be precluded.

Dryer, Frederick L.; Chaos, Marcos [Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, NJ 08544-5263 (United States)

2008-01-15T23:59:59.000Z

475

Optimal Shape Design for Polymer Electrolyte Membrane Fuel Cell Cathode Air Channel: Modelling, Computational and Mathematical Analysis .  

E-Print Network [OSTI]

??Hydrogen fuel cells are devices used to generate electricity from the electrochemical reaction between air and hydrogen gas. An attractive advantage of these devices is… (more)

Al-Smail, Jamal Hussain

2012-01-01T23:59:59.000Z

476

Synchronization of organ pipes by means of air flow coupling: experimental observations and modeling  

E-Print Network [OSTI]

We report measurements on two organ pipes positioned side by side. We investigate two different questions. First, the mutual influence of two pipes with different pitch. In analogy to the coupling of two nonlinear oscillators with feedback, one observes a frequency locking, which can be explained by synchronization theory. Second, we measure the dependence of the frequency of the signals emitted by two mutually detuned pipes with varying distance between the pipes. The spectrum shows a broad ``hump'' structure, not found for coupled oscillators. This indicates a complicated hydrodynamical coupling of the two jets creating the acoustic field when exiting from the pipe mouth. We interpret our acoustic measurements with a model for the flow which exits from the flues of the pipes.

Abel, M; Gerhard-Multhaupt, R

2005-01-01T23:59:59.000Z

477

Market and behavioral barriers to energy efficiency: A preliminary evaluation of the case for tariff financing in California  

E-Print Network [OSTI]

for central air conditioner replacements Efficiency level 20state, replacement of outdated central air conditioners orAir Conditioners .. 15   Furnaces 16   Water heaters .. 17   Potential savings from rental housing unit water heater replacements .

Fujita, K. Sydny

2012-01-01T23:59:59.000Z

478

CONTROL SYSTEM FOR SOLAR HEATING and COOLING  

E-Print Network [OSTI]

~O"')4 REFERENCES The air conditioner work is the subject ofAmmonia-Water Absorption Air Conditioner", by M. Simmons, R.water absorption air conditioner, (1) and the establishment

Dols, C.

2010-01-01T23:59:59.000Z

479

BPM Motors in Residential Gas Furnaces: What are the Savings?  

E-Print Network [OSTI]

Comfort Series 13 Air Conditioner with Puron Refrigerant.for new houses with 3.5 ton air-conditioners from a study ofblower use by the air conditioner and stand-by power.

Lutz, James; Franco, Victor; Lekov, Alex; Wong-Parodi, Gabrielle

2006-01-01T23:59:59.000Z

480

TWOZONE USERS MANUAL  

E-Print Network [OSTI]

9. Sizing chart for air conditioner. z ~::~~OOOOOOOOOOOOOOOOoperation of either an air conditioner and/or an evaporativecooler, improved air-conditioner algorithm, ability to read

Gadgil, Ashok J.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner model" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

TWOZONE USERS MANUAL  

E-Print Network [OSTI]

9. Sizing chart for air conditioner. z ~::~~OOOOOOOOOOOOOOOOoperation of either an air conditioner and/or an evaporativecooler, improved air-conditioner algorithm, ability to read

Gadgil, Ashok J.

2008-01-01T23:59:59.000Z

482

Global Potential of Energy Efficiency Standards and Labeling Programs  

E-Print Network [OSTI]

impact of room air conditioners energy labels in Malaysia."of electric Room Air Conditioner." Energy Economics 20Standard Levels for Room Air Conditioners. McNeil, M. A. ,

McNeil, Michael A

2008-01-01T23:59:59.000Z

483

Modelin the Transport and Chemical Evolution of Onshore and Offshore Emissions and Their Impact on Local and Regional Air Quality Using a Variable-Grid-Resolution Air Quality Model  

SciTech Connect (OSTI)

The overall objective of this research project was to develop an innovative modeling technique to adequately model the offshore/onshore transport of pollutants. The variable-grid modeling approach that was developed alleviates many of the shortcomings of the traditionally used nested regular-grid modeling approach, in particular related to biases near boundaries and the excessive computational requirements when using nested grids. The Gulf of Mexico region contiguous to the Houston-Galveston area and southern Louisiana was chosen as a test bed for the variable-grid modeling approach. In addition to the onshore high pollution emissions from various sources in those areas, emissions from on-shore and off-shore oil and gas exploration and production are additional sources of air pollution. We identified case studies for which to perform meteorological and air quality model simulations. Our approach included developing and evaluating the meteorological, emissions, and chemistry-transport modeling components for the variable-grid applications, with special focus on the geographic areas where the finest grid resolution was used. We evaluated the performance of two atmospheric boundary layer (ABL) schemes, and identified the best-performing scheme for simulating mesoscale circulations for different grid resolutions. Use of a newly developed surface data assimilation scheme resulted in improved meteorological model simulations. We also successfully ingested satellite-derived sea surface temperatures (SSTs) into the meteorological model simulations, leading to further improvements in simulated wind, temperature, and moisture fields. These improved meteorological fields were important for variable-grid simulations, especially related to capturing the land-sea breeze circulations that are critical for modeling offshore/onshore transport of pollutants in the Gulf region. We developed SMOKE-VGR, the variable-grid version of the SMOKE emissions processing model, and tested and evaluated this new system. We completed the development of our variable-grid-resolution air quality model (MAQSIP-VGR) and performed various diagnostic tests related to an enhanced cloud parameterization scheme. We also developed an important tool for variable-grid graphics using Google Earth. We ran the MAQSIP-VGR for the Houston-Galveston and southern Louisiana domains for an August 23 to September 2, 2002, episode. Results of the modeling simulations highlighted the usefulness of the variable-grid modeling approach when simulating complex terrain processes related to land and sea close to an urban area. Our results showed that realistic SST patterns based on remote sensing are critical to capturing the land-sea breeze, in particular the inland intrusion of the reversed mesoscale circulation that is critical for simulating air pollution over urban areas near coastal regions. Besides capturing the correct horizontal gradient between land and sea surface temperatures, it is important to use an adequate ABL scheme in order to quantify correctly the vertical profiles of various parameters. The ABL scheme should capture the dynamics of the marine boundary layer, which is not often considered in a typical simulation over land. Our results further showed the effect of using satellite-derived SSTs on the horizontal and vertical extent of the modeled pollution pattern, and the increase in hourly ozone concentrations associated with changes in ABL characteristics resulting from the enhanced mesoscale circulation in the lower troposphere.

Adel Hanna

2008-10-16T23:59:59.000Z

484

Comparing three vegetation monoterpene emission models to measured gas concentrations with a model of meteorology, air chemistry and chemical transport  

SciTech Connect (OSTI)

Biogenic volatile organic compounds (BVOCs) are essential in atmospheric chemistry because of their chemical reactions that produce and destroy tropospheric ozone, their effects on aerosol formation and growth, and their potential influence on global warming. As one of the important BVOC groups, monoterpenes have been a focus of scientific attention in atmospheric research. Detailed regional measurements and model estimates are needed to study emission potential and the monoterpene budget on a global scale. Since the use of empirical measurements for upscaling is limited by many physical and biological factors such as genetic variation, temperature and light, water availability, seasonal changes, and environmental stresses, comprehensive inventories over larger areas are difficult to obtain.

Smolander, S.; He, Q.; Mogensen, Ditte; Zhou, L.; Back, J.; Ruuskanen, T.; Noe, S.; Guenther, Alex B.; Aaltonen, H.; Kulmala, M.; Boy, Michael

2014-10-07T23:59:59.000Z

485

Development of advanced cloud parameterizations to examine air quality, cloud properties, and cloud-radiation feedback in mesoscale models  

SciTech Connect (OSTI)

The distribution of atmospheric pollutants is governed by dynamic processes that create the general conditions for transport and mixing, by microphysical processes that control the evolution of aerosol and cloud particles, and by chemical processes that transform chemical species and form aerosols. Pollutants emitted into the air can undergo homogeneous gas reactions to create a suitable environment for the production by heterogeneous nucleation of embryos composed of a few molecules. The physicochemical properties of preexisting aerosols interact with newly produced embryos to evolve by heteromolecular diffusion and coagulation. Hygroscopic particles wig serve as effective cloud condensation nuclei (CCN), while hydrophobic particles will serve as effective ice-forming nuclei. Clouds form initially by condensation of water vapor on CCN and evolve in a vapor-liquid-solid system by deposition, sublimation, freezing, melting, coagulation, and breakup. Gases and aerosols that enter the clouds undergo aqueous chemical processes and may acidity hydrometer particles. Calculations for solar and longwave radiation fluxes depend on how the respective spectra are modified by absorbers such as H{sub 2}O, CO{sub 2}, O{sub 3}, CH{sub 4}, N{sub 2}O, chlorofruorocarbons, and aerosols. However, the flux calculations are more complicated for cloudy skies, because the cloud optical properties are not well defined. In this paper, key processes such as tropospheric chemistry, cloud microphysics parameterizations, and radiation schemes are reviewed in terms of physicochemical processes occurring, and recommendations are made for the development of advanced modules applicable to mesoscale models.

Lee, In Young

1993-09-01T23:59:59.000Z

486

Jengeih Tamba U.S. Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

report. The study states that between 2006 and the beginning of 2013, manufacturers of residential furnaces, air conditioners, heat pumps and commercial unitary air conditioners...

487

Impacts of Imported Liquefied Natural Gas on Residential Appliance Components: Literature Review  

E-Print Network [OSTI]

on New FVIR Water Heaters." Retrieved 04/17/2009, 2009, fromAir Conditioners, Water Heaters, Direct Heating Equipment,Air Conditioners, Water Heaters, Direct Heating Equipment,

Lekov, Alex

2010-01-01T23:59:59.000Z

488

Using National Survey Data to Estimate Lifetimes of Residential Appliances  

E-Print Network [OSTI]

furnaces, boilers, water heaters, room air-conditioners,furnaces, boilers, water heaters, room air-conditioners (and Electric Storage Water Heaters Table 6 and 7 show the

Lutz, James D.

2013-01-01T23:59:59.000Z

489

Page 1 of 3 Radiogram No. 1679u Form 24 for 03/02/2013  

E-Print Network [OSTI]

Subsystem Preventive Maintenance, Group E FGB 2 Fan Cleaning Inspection of Air Conditioner Inspection Inspection of Air Conditioner Inspection and Cleaning of Auxiliary Computer System () Laptops

490

On-line Chemistry within WRF: Description and Evaluation of a State-of-the-Art Multiscale Air Quality and Weather Prediction Model  

SciTech Connect (OSTI)

This is a conference proceeding that is now being put together as a book. This is chapter 2 of the book: "INTEGRATED SYSTEMS OF MESO-METEOROLOGICAL AND CHEMICAL TRANSPORT MODELS" published by Springer. The chapter title is "On-line Chemistry within WRF: Description and Evaluation of a State-of-the-Art Multiscale Air Quality and Weather Prediction Model." The original conference was the COST-728/NetFAM workshop on Integrated systems of meso-meteorological and chemical transport models, Danish Meteorological Institute, Copenhagen, May 21-23, 2007.

Grell, Georg; Fast, Jerome D.; Gustafson, William I.; Peckham, Steven E.; McKeen, Stuart A.; Salzmann, Marc; Freitas, Saulo

2010-01-01T23:59:59.000Z

491

TLCD EXPERIMENTS In theory, there is no difference between theory and practice.  

E-Print Network [OSTI]

channels signal conditioner signal conditioner position transmitter 4-20 mA to positioner Shaking Table Building Model shown in detail 80 psi Pneumatic Air-line Computer (a) (b) #12;135 ball valve of 3.8 cm (1

Kareem, Ahsan

492

Air UCI Summer Training Program in Environmental  

E-Print Network [OSTI]

Air UCI Summer Training Program in Environmental Chemistry for Science Teachers I. July 11 ­ July · Lectures by AirUCI faculty · Lab tours of AirUCI laboratories · Follow-up for several years Distribution Models and predictions. Syllabus: Lectures Every AirUCI faculty member is actively involved

Nizkorodov, Sergey

493

Friedrich: ENERGY STAR Referral (SM18M30)  

Broader source: Energy.gov [DOE]

DOE referred the matter of Friedrich room air conditioner model SM18M30 to the EPA for appropriate action after DOE testing showed that the model does not meet the ENERGY STAR specification.

494

Haier: ENERGY STAR Referral (ESA3087)  

Broader source: Energy.gov [DOE]

DOE referred Haier room air conditioner model ESA3087 to EPA, brand manager of the ENERGY STAR program, for appropriate action after DOE testing revealed that the model does not meet ENERGY STAR requirements.

495

Cascade Reverse Osmosis Air Conditioning System: Cascade Reverse Osmosis and the Absorption Osmosis Cycle  

SciTech Connect (OSTI)

BEETIT Project: Battelle is developing a new air conditioning system that uses a cascade reverse osmosis (RO)-based absorption cycle. Analyses show that this new cycle can be as much as 60% more efficient than vapor compression, which is used in 90% of air conditioners. Traditional vapor-compression systems use polluting liquids for a cooling effect. Absorption cycles use benign refrigerants such as water, which is absorbed in a salt solution and pumped as liquid—replacing compression of vapor. The refrigerant is subsequently separated from absorbing salt using heat for re-use in the cooling cycle. Battelle is replacing thermal separation of refrigerant with a more efficient reverse osmosis process. Research has shown that the cycle is possible, but further investment will be needed to reduce the number of cascade reverse osmosis stages and therefore cost.

None

2010-09-01T23:59:59.000Z

496

Modeling diffusion of electrical appliances in the residential sector  

SciTech Connect (OSTI)

This paper presents a methodology for modeling residential appliance uptake as a function of root macroeconomic drivers. The analysis concentrates on four major energy end uses in the residential sector: refrigerators, washing machines, televisions and air conditioners. The model employs linear regression analysis to parameterize appliance ownership in terms of household income, urbanization and electrification rates according to a standard binary choice (logistic) function. The underlying household appliance ownership data are gathered from a variety of sources including energy consumption and more general standard of living surveys. These data span a wide range of countries, including many developing countries for which appliance ownership is currently low, but likely to grow significantly over the next decades as a result of economic development. The result is a 'global' parameterization of appliance ownership rates as a function of widely available macroeconomic variables for the four appliances studied, which provides a reliable basis for interpolation where data are not available, and forecasting of ownership rates on a global scale. The main value of this method is to form the foundation of bottom-up energy demand forecasts, project energy-related greenhouse gas emissions, and allow for the construction of detailed emissions mitigation scenarios.

McNeil, Michael A.; Letschert, Virginie E.

2009-11-22T23:59:59.000Z

497

System Modeling and Building Energy Simulations of Gas Engine Driven Heat Pump  

SciTech Connect (OSTI)

To improve the system performance of a gas engine driven heat pump (GHP) system, an analytical modeling and experimental study has been made by using desiccant system in cooling operation (particularly in high humidity operations) and suction line waste heat recovery to augment heating capacity and efficiency. The performance of overall GHP system has been simulated with a detailed vapor compression heat pump system design model. The modeling includes: (1) GHP cycle without any performance improvements (suction liquid heat exchange and heat recovery) as a baseline (both in cooling and heating mode), (2) the GHP cycle in cooling mode with desiccant system regenerated by waste heat from engine incorporated, (3) GHP cycle in heating mode with heat recovery (recovered heat from engine). According to the system modeling results, by using the desiccant system the sensible heat ratio (SHR- sensible heat ratio) can be lowered to 40%. The waste heat of the gas engine can boost the space heating efficiency by 25% at rated operating conditions. In addtion,using EnergyPlus, building energy simulations have been conducted to assess annual energy consumptions of GHP in sixteen US cities, and the performances are compared to a baseline unit, which has a electrically-driven air conditioner with the seasonal COP of 4.1 for space cooling and a gas funace with 90% fuel efficiency for space heating.

Mahderekal, Isaac [Oak Ridge National Laboratory (ORNL); Vineyard, Edward [Oak Ridge National Laboratory (ORNL)

2013-01-01T23:59:59.000Z

498

THE AIR-QUALITY MODELING SYSTEM: A Critical Component Of The Scientific Toolbox For Policy-Maker  

E-Print Network [OSTI]

, accumulation, transport, and removal of primary and secondary air pollutants over urban and regional spatialAmerica, playing a supportive role Canada and Mexico, while being a required part of the development of State for evaluating alternative emission-control strategies for reducing ambient tropospheric O3 concentrations

499

3, 35433588, 2003 3-D air pollution  

E-Print Network [OSTI]

ACPD 3, 3543­3588, 2003 3-D air pollution modelling L. M. Frohn et al. Title Page Abstract hemispheric nested air pollution model L. M. Frohn, J. H. Christensen, J. Brandt, C. Geels, and K. M. Hansen 2003 Correspondence to: L. M. Frohn (lmf@dmu.dk) 3543 #12;ACPD 3, 3543­3588, 2003 3-D air pollution

Boyer, Edmond

500

air puffs produced: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Databases and Resources Websites Summary: puff diffusion model. INIS descriptors: AIR POLLUTION; CLUSTER EMMISSION MODEL; DIFFUSION; GAUSSIAN PROCESSES; NUMERICAL SOLUTION;...