1

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network [OSTI]

Baseline Efficient Air Conditioners . . . . . . 28 AverageEfficient Air Conditioners . . . . . . . . . . . . . . . . .Btu/h Commercial Air Conditioners . . . . . . . . . . . . .

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

2

Development of minimum efficiency standards for large capacity air conditioners, and commercial water heaters, refrigerators, and freezers. Final report  

SciTech Connect (OSTI)

The California Energy Resources Conservation and Development Commission has promulgated appliance energy efficiency standards and energy conservation standards for new construction with the objective of reducing energy consumption in the State of California. The following appliance categories are specifically addressed: large capacity air conditioners; commercial water heaters; and commercial refrigerators and freezers. The tasks that have been performed include: an energy use pattern study for the subject equipment; an examination of the size distribution of commercial air conditioning equipment; an examination of the different types of commercial air conditioning systems; an evaluation of the effectiveness of economizers in reducing commercial air conditioning system energy consumption in California; an examination of the effects of oversizing commercial air conditioners; a detailed study of supermarket refrigeration and air conditioning equipment; an evaluation of the economic feasibility of utilizing air conditioner waste heat to heat water; an assessment of the applicability of existing test procedures for small water heaters to large water heaters; and a brief investigation of the marketing and distribution systems for air conditioning and refrigeration equipment. Results of the efforts are described.

Merrill, P.S.; Rettberg, R.J.; Erickson, R.C.; Toor, J.S.

1980-05-01T23:59:59.000Z

3

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network [OSTI]

Products: Central Air Conditioners and Heat Pumps Energyof Improved Central Air Conditioner Efficiencies Authorsresidential-type central air conditioner energy-efficiency

Rosenquist, G.

2010-01-01T23:59:59.000Z

4

Dirty air conditioners: Energy implications of coil fouling  

E-Print Network [OSTI]

1473. Neal, L. 1992. Air Conditioner Efficiency in the Realof a Residential Air Conditioner. Proceedings of the 1992of new residential air conditioners in Phoenix, Arizona.

Siegel, Jeffrey; Walker, Iain; Sherman, Max

2002-01-01T23:59:59.000Z

5

DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS  

E-Print Network [OSTI]

DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS K. Dao, M.ABSORPTION AIR CONDITIONERS AND HEAT PUMPS* K. DAO, M.

Dao, K.

2013-01-01T23:59:59.000Z

6

Four Central Air Conditioners Determined Noncompliant With Energy...  

Broader source: Energy.gov (indexed) [DOE]

Heat Pumps DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards DOE Orders AeroSys to Halt...

7

AIR CONDITIONER REQUEST EXTREME MEDICAL CIRCUMSTANCES  

E-Print Network [OSTI]

AIR CONDITIONER REQUEST DUE TO EXTREME MEDICAL CIRCUMSTANCES TO BE COMPLETED BY ATTENDING Moderate Significant Is the use of an air conditioner desirable Yes No OR essential Yes No to the management of allergy? Is the use of an air conditioner

8

High-Efficiency Window Air Conditioners - Building America Top...  

Broader source: Energy.gov (indexed) [DOE]

Window Air Conditioners - Building America Top Innovation This photo shows a window air conditioning unit in place in a window frame. Window air conditioners are inexpensive,...

9

Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners  

E-Print Network [OSTI]

Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners John Shugars, Consultant ofcommercialpackaged air conditioners, explore the reasons behindthis efficiency gap, and assess opportunities). Although sales of rooftop air conditioners have steadily increased over the past decade, the efficiency

10

DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS  

E-Print Network [OSTI]

SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS K.Driven Absorption Air-Conditioner", K. Dao, M. Simmons, R.SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS* K.

Dao, K.

2013-01-01T23:59:59.000Z

11

Electrolux Gibson Air Conditioner and Equator Clothes Washer...  

Broader source: Energy.gov (indexed) [DOE]

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing...

12

Natural Gas Heat Pump and Air Conditioner | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Natural Gas Heat Pump and Air Conditioner Natural Gas Heat Pump and Air Conditioner Lead Performer: Thermolift - Stony Brook, NY Partners: -- New York State Energy Research &...

13

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

Blast-Type Air Conditioners and Heat Pump. The correspondingair/air air conditioners and heat pumps. Some improvementsconnected air- conditioner (heat pump) units, household

Zhou, Nan

2010-01-01T23:59:59.000Z

14

Covered Product Category: Residential Central Air Conditioners...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

operate on single-phase current and have cooling capacities less than 65,000 Btuh. Room air conditioners (window and through-the-wall) are covered by a separate specification,...

15

Rating of Mixed Split Residential Air Conditioners  

E-Print Network [OSTI]

A methodology is presented for rating the performance of mixed, split residential air conditioners. The method accounts for the impact on system performance of the indoor evaporator, expansion device and fan; three major components that are likely...

Domanski, P. A.

1988-01-01T23:59:59.000Z

16

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

Results for Room Air Conditioners Nan Zhou David FridleyTable of Contents I. Air Conditioner Round Robin TestingAir Conditioners..

Zhou, Nan

2010-01-01T23:59:59.000Z

17

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

E-Print Network [OSTI]

Measuring Short-term Air Conditioner Demand Reductions forMeasuring Short-term Air Conditioner Demand Reductions forpilots have shown that air conditioner (AC) electric loads

Bode, Josh

2013-01-01T23:59:59.000Z

18

Technical and economic analysis of energy efficiency of Chinese room air conditioners  

E-Print Network [OSTI]

Sector Study of Room Air Conditioners in China) , ChinaQi Shichang ( China’s Air Conditioner Market ), China Lightand Constant-Speed Air Conditioners." ASHRAE Transactions.

Fridley, David G.; Rosenquist, Gregory; Jiang, Lin; Li, Aixian; Xin, Dingguo; Cheng, Jianhong

2001-01-01T23:59:59.000Z

19

Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners  

E-Print Network [OSTI]

Final Summary Report by Air Conditioner Evaluation Standardreversible residential air conditioners and heat pumps usingJFS, 2007: “New Air Conditioners with Infrared Sensors

Shah, Nihar

2014-01-01T23:59:59.000Z

20

Stirling Air Conditioner for Compact Cooling  

SciTech Connect (OSTI)

BEETIT Project: Infinia is developing a compact air conditioner that uses an unconventional high efficient Stirling cycle system (vs. conventional vapor compression systems) to produce cool air that is energy efficient and does not rely on polluting refrigerants. The Stirling cycle system is a type of air conditioning system that uses a motor with a piston to remove heat to the outside atmosphere using a gas refrigerant. To date, Stirling systems have been expensive and have not had the right kind of heat exchanger to help cool air efficiently. Infinia is using chip cooling technology from the computer industry to make improvements to the heat exchanger and improve system performance. Infinia’s air conditioner uses helium gas as refrigerant, an environmentally benign gas that does not react with other chemicals and does not burn. Infinia’s improvements to the Stirling cycle system will enable the cost-effective mass production of high-efficiency air conditioners that use no polluting refrigerants.

None

2010-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

YMGI Through-the-Wall Air Conditioner Determined Noncompliant...  

Energy Savers [EERE]

air conditioner is one solution to cooling part of a house. | Photo courtesy of iStockphotoLUke1138. Ductless Mini-Split Air Conditioners Ductless, Mini-Split Heat Pumps...

22

The effects of galvanic corrosion on air conditioner performance  

E-Print Network [OSTI]

Corrosion of air conditioner outdoor heat exchangers (condensers) poses a significant problem for consumers living in coastal regions. This research sought to experimentally determine effects of galvanic corrosion on air conditioner condenser coils...

Grisham, Phillip Ryan

2001-01-01T23:59:59.000Z

23

Laboratory Performance Testing of Residential Window Air Conditioners  

SciTech Connect (OSTI)

Window air conditioners are the dominant cooling product for residences, in terms of annual unit sales. They are inexpensive, portable and can be installed by the owner. For this reason, they are an attractive solution for supplemental cooling, for retrofitting air conditioning into a home which lacks ductwork, and for renters. Window air conditioners for sale in the United States are required to meet very modest minimum efficiency standards. Four window air conditioners' performance were tested in the Advanced HVAC Systems Laboratory on NREL's campus in Golden, CO. In order to separate and study the refrigerant system's performance, the unit's internal leakage pathways, the unit's fanforced ventilation, and the leakage around the unit resulting from installation in a window, a series of tests were devised that focused on each aspect of the unit's performance. These tests were designed to develop a detailed performance map to determine whole-house performance in different climates. Even though the test regimen deviated thoroughly from the industry-standard ratings test, the results permit simple calculation of an estimated rating for both capacity and efficiency that would result from a standard ratings test. Using this calculation method, it was found that the three new air conditioners' measured performance was consistent with their ratings. This method also permits calculation of equivalent SEER for the test articles. Performance datasets were developed across a broad range of indoor and outdoor operating conditions, and used them to generate performance maps.

Winkler, J.; Booten, C.; Christensen, D.; Tomerlin, J.

2013-03-01T23:59:59.000Z

24

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner...  

Broader source: Energy.gov (indexed) [DOE]

Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards DOE Orders AeroSys to Halt Distribution of...

25

Covered Product Category: Room Air Conditioners  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance across a variety of product categories, including room air conditioners, which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

26

Covered Product Category: Residential Central Air Conditioners  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance across a variety of product categories, including residential central air conditioners (CACs), which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

27

Assessing the Impact of Measurement Policy on the Accuracy of Certified Energy Efficiency Ratio for Split-System Air Conditioners  

E-Print Network [OSTI]

Efficiency of Unitary Air Conditioners and Heat Pumps,and Validation of Unitary Air Conditioner and Heat PumpC.W. (1994). Room Air Conditioner System Modeling, Air

Yu, Bingyi

2013-01-01T23:59:59.000Z

28

EECBG Direct Equipment Purchase Air Conditioner Guide Equipment Type  

E-Print Network [OSTI]

EECBG Direct Equipment Purchase Air Conditioner Guide Equipment Type Size Category (Btu/h) Size.ahridirectory.org/ceedirectory/pages/ac/cee/defaultSearch.aspx 12,000 Btu/h = 1 ton Less than 65,000 Btu/h Air Conditioners, Air Cooled Air Conditioners, Water completed by the California Energy Commission at a rate of 12,000 Btu/h per ton of air conditioning Source

29

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

E-Print Network [OSTI]

for Refrigerators and Air Conditioners in India. Michael A.followed by room air conditioners. Both of these appliancesfrost-free units. Room air conditioners in India have

McNeil, Michael A.

2010-01-01T23:59:59.000Z

30

Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges  

E-Print Network [OSTI]

Efficiency of Room Air Conditioners in India: OpportunitiesStar Labeled room Air Conditioners. ” Ministry of Power (of Superefficient Room Air Conditioners,” Lawrence Berkeley

Phadke, Amol

2014-01-01T23:59:59.000Z

31

Determining benefits and costs of improved central air conditioner efficiencies  

SciTech Connect (OSTI)

Economic impacts on individual consumers from possible revisions to U.S. residential-type central air conditioner energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a central air conditioner and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers due to modest increases in efficiency are significant. For an efficiency increase of 20percent over the existing minimum standard (i.e., 12 SEER), 35percent of households with central air conditioners experience significant LCC savings, with an average savings of $453, while 25percent show significant LCC losses, with an average loss of $158 compared to apre-standard LCC average of $5,170. The remainder of the population (40percent) are largely unaffected.

Rosenquist, G.; Levok, A.; Chan, P.; McMahon, J.

2001-01-12T23:59:59.000Z

32

APPROVED ICE STORAGE AIR CONDITIONERS Revised as of 06-18-2008  

E-Print Network [OSTI]

APPROVED ICE STORAGE AIR CONDITIONERS Revised as of 06-18-2008 The following vendors and their ice storage air conditioners models can be used in the ice storage air conditioner compliance option. Input

33

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network [OSTI]

Standard Levels for Room Air Conditioners Michael A. McNeilFigure 1 – MEPS for 1.5 ton Window Air Conditioners – 1994-4 Figure 2 – Air Conditioner Test Data and Rating Plan -

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

34

Air Conditioner Compressor Performance Model  

SciTech Connect (OSTI)

During the past three years, the Western Electricity Coordinating Council (WECC) Load Modeling Task Force (LMTF) has led the effort to develop the new modeling approach. As part of this effort, the Bonneville Power Administration (BPA), Southern California Edison (SCE), and Electric Power Research Institute (EPRI) Solutions tested 27 residential air-conditioning units to assess their response to delayed voltage recovery transients. After completing these tests, different modeling approaches were proposed, among them a performance modeling approach that proved to be one of the three favored for its simplicity and ability to recreate different SVR events satisfactorily. Funded by the California Energy Commission (CEC) under its load modeling project, researchers at Pacific Northwest National Laboratory (PNNL) led the follow-on task to analyze the motor testing data to derive the parameters needed to develop a performance models for the single-phase air-conditioning (SPAC) unit. To derive the performance model, PNNL researchers first used the motor voltage and frequency ramping test data to obtain the real (P) and reactive (Q) power versus voltage (V) and frequency (f) curves. Then, curve fitting was used to develop the P-V, Q-V, P-f, and Q-f relationships for motor running and stalling states. The resulting performance model ignores the dynamic response of the air-conditioning motor. Because the inertia of the air-conditioning motor is very small (H<0.05), the motor reaches from one steady state to another in a few cycles. So, the performance model is a fair representation of the motor behaviors in both running and stalling states.

Lu, Ning; Xie, YuLong; Huang, Zhenyu

2008-09-05T23:59:59.000Z

35

2015-02-12 Issuance: Test Procedures for Portable Air Conditioners...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Test Procedures for Portable Air Conditioners; Notice of Proposed Rulemaking 2015-02-12 Issuance: Test Procedures for Portable Air Conditioners; Notice of Proposed Rulemaking...

36

E-Print Network 3.0 - air conditioners electronic Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AND NEXT GENERATION Summary: ... xvi Adsorption Heat Pumps and Air Conditioners ... xvi Absorption Chillers......

37

E-Print Network 3.0 - air conditioner screening Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AND NEXT GENERATION Summary: ... xvi Adsorption Heat Pumps and Air Conditioners ... xvi Absorption Chillers......

38

E-Print Network 3.0 - adsorption air conditioner Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AND NEXT GENERATION Summary: ... xvi Adsorption Heat Pumps and Air Conditioners ... xvi Absorption Chillers......

39

Commercial Central Air Conditioners, Purchasing Specifications for Energy-Efficient Products (Fact Sheet)  

SciTech Connect (OSTI)

Energy efficiency purchasing specifications for federal procurements of commercial central air conditioners.

Not Available

2011-02-01T23:59:59.000Z

40

Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners  

E-Print Network [OSTI]

replacement options have and are being developed. Choice of Refrigerant: The most efficient air conditioners

Shah, Nihar

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS  

E-Print Network [OSTI]

AIR CONDITIONERS AND HEAT PUMPS K. Dao, M. Wahlig, E. Wali,are liquid paths. DM: multistage pump driver, driven by highvapor. DW: main circulation pump driven by strong absorbent.

Dao, K.

2013-01-01T23:59:59.000Z

42

Improving Air-Conditioner and Heat Pump Modeling (Presentation)  

SciTech Connect (OSTI)

A new approach to modeling residential air conditioners and heat pumps allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted 'behind-the-scenes' without negatively impacting the reliability of energy simulations.

Winkler, J.

2012-03-01T23:59:59.000Z

43

An Analysis of Efficiency Improvements in Room Air Conditioner  

E-Print Network [OSTI]

NAECA NATIONAL APPLIANCE ENERGY CONSERVATION ACT NBS NATIONAL BUREAU OF STANDARDS NECPA NATIONAL ENERGY CONSERVATION POLICY ACT NTU NUMBER OF TRANSFER UNITS OEM ORIGINAL EQUIPMENT MANUFACTURER ORNL OAK RIDGE NATIONAL LABORATORY RAC ROOM AIR CONDITIONER.... There are two public domain models that we have considered using for this analysis: the Oak Ridge National Laboratory (ORNL) heat pump model [1] and the Arthur D. Little (ADL) room air conditioner model [2]. The ORNL model was completed in 1981. Although...

O'Neal, D. L.; Penson, S. B.

1988-01-01T23:59:59.000Z

44

Residential Air Conditioner Direct Load Control "Energy Partners Program"  

E-Print Network [OSTI]

RESIDENTIAL AIR CONDITIONER DIRECT LOAD CONTROL "ENERGY PARTNERS PROGRAMn John D. Cook Supervisor Houston ABSTRACT Demand side management programs like Energy Partners can provide an effective peak reducing capability which within a.... In this partnership the customer allows HLfP to install a I switch on his/her air conditioner or heat pump and i periodically cycle the unit off during the hottest summer 1 days. In return the customer benefits by receiving an incentive payment, as well...

Cook, J. D.

1994-01-01T23:59:59.000Z

45

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

E-Print Network [OSTI]

Central Air Conditioners and Heat Pumps Energy ConservationCentral Air Conditioners and Heat Pumps. Washington DC:Central Air Conditioners and Heat Pumps Energy Conservation

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-01-01T23:59:59.000Z

46

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

E-Print Network [OSTI]

Products: Central Air Conditioners and Heat Pumps EnergyResidential Central Air Conditioners and Heat Pumps.Products: Central Air Conditioners and Heat Pumps Energy

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-01-01T23:59:59.000Z

47

Assessing the Impact of Measurement Policy on the Accuracy of Certified Energy Efficiency Ratio for Split-System Air Conditioners  

E-Print Network [OSTI]

of Unitary Air Conditioners and Heat Pumps, ASHRAE, 1791of Unitary Air Conditioner and Heat Pump Simulation Modelsfor Rating Unitary Air-Conditioning and Heat Pump Equipment,

Yu, Bingyi

2013-01-01T23:59:59.000Z

48

Installation of Window Air Conditioners Page 1 of 2 Virginia Polytechnic Institute and State University No. 5705 Rev.: 3  

E-Print Network [OSTI]

Installation of Window Air Conditioners Page 1 of 2 Virginia Polytechnic Institute and State __________________________________________________________________________________ Subject: Installation of Window Air Conditioners........................................................................................................................................1 1. Purpose To define a policy for installation of window air conditioners that avoids exterior

Buehrer, R. Michael

49

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner...  

Energy Savers [EERE]

Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models...

50

Influence of Air Conditioner Operation on Electricity Use and Peak Demand  

E-Print Network [OSTI]

Electricity demand due to occupant controlled room air conditioners in a large mater-metered apartment building is analyzed. Hourly data on the electric demand of the building and of individual air conditioners are used in analyses of annual...

McGarity, A. E.; Feuermann, D.; Kempton, W.; Norford, L. K.

1987-01-01T23:59:59.000Z

51

Air Conditioner User Behavior in a Master-Metered Apartment Building  

E-Print Network [OSTI]

Air conditioner operation was studied in order to understand how energy consumption and peak power are determined by user behavior, equipment operation and building characteristics. In a multi-family building, thirteen room air conditioners were...

Kempton, W.; Feuermann, D.; McGarity, A. E.

1987-01-01T23:59:59.000Z

52

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

check in the air conditioning products category is indicatednumber of domestic air conditioning product manufacturers100 million worth of air conditioner products to 14 major

Zhou, Nan

2010-01-01T23:59:59.000Z

53

STATE OF CALIFORNIA CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS  

E-Print Network [OSTI]

STATE OF CALIFORNIA CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS CEC Volume Single Zone Unitary Air Conditioner and Heat Pump Systems (Page 1 of 4) Project Name CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS CEC-MECH-3A (Revised 08

54

Technical and economic analysis of energy efficiency of Chinese room air conditioners  

SciTech Connect (OSTI)

China has experienced tremendous growth in the production and sales of room air conditioners over the last decade. Although minimum room air conditioner energy efficiency standards have been in effect since 1989, no efforts were made during most of the 1990's to update the standard to be more reflective of current market conditions. In 1999, China's State Bureau of Technical Supervision (SBTS) included in their annual plan the development and revision of the 1989 room air conditioner standard, and experts from SBTS worked together with LBNL to analyze the new standards. Based on the engineering and life cycle-cost analyses performed, the most predominant type of room air conditioner in the Chinese market (split-type with a cooling capacity between 2500 and 4500 W (8500 Btu/h and 15,300Btu/h)) can have its efficiency increased cost-effectively to an energy efficiency ratio (EER) of 2.92 W/W (9.9 Btu/hr/W). If an EER standard of 2.92 W/W became effective in 2001, Chinese consumers would be estimated to save over 3.5 billion Yuan (420 million U.S. dollars) over the period of 2001-2020. Carbon emissions over the same period would be reduced by approximately 12 million metric tonnes.

Fridley, David G.; Rosenquist, Gregory; Jiang, Lin; Li, Aixian; Xin, Dingguo; Cheng, Jianhong

2001-02-01T23:59:59.000Z

55

Room Air Conditioners | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to: navigation, searchVirginia BlueRiverwoods,RockRipple,Rollingwood, Texas:Conditioners Jump

56

Development of vehicle magnetic air conditioner (VMAC) technology. Final report  

SciTech Connect (OSTI)

The objective of Phase I was to explore the feasibility of the development of a new solid state refrigeration technology - magnetic refrigeration - in order to reduce power consumption of a vehicle air conditioner by 30%. The feasibility study was performed at Iowa State University (ISU) together with Astronautics Corporation of America Technology Center (ACATC), Madison, WI, through a subcontract with ISU.

Gschneidner, Karl A., Jr.; Pecharsky, V.K.; Jiles, David; Zimm, Carl B.

2001-08-28T23:59:59.000Z

57

Monitoring and evaluation of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached houses in Austin, Texas  

SciTech Connect (OSTI)

The US DOE initiated this project to evaluate the performance of an air conditioner retrofit program in Austin, Texas. The City's Austin's Resource Management Department pursued this project to quantify the retrofit effect of replacing low-efficiency air conditioners with high-efficiency air conditioners in single-family detached homes. If successfully implemented, this retrofit program could help defer construction of a new power plant which is a major goal of this department. The project compares data collected from 12 houses during two cooling seasons under pre-retrofit and then post-retrofit air conditioner units. The existing low-efficiency air conditioners were monitored during the 1987 cooling season, replaced during the 1987--88 heating season with new, smaller sized, high-efficiency units, and then monitored again during the 1988 cooling season. Results indicated that the air conditioner retrofits reduce the annual air conditioner electric consumption and peak electric demand by an average of 38%. When normalized to the nominal capacity of the air conditioner, average demand savings were 1.12 W/ft{sup 2} and estimated annual energy savings were 1.419 kWh/ft{sup 2}. Individual air conditioner power requirements were found to be a well defined function of outdoor temperature as expected. In the absence of detailed data, estimates of the peak demand reductions of new air conditioners can be made from the manufacturer's specifications. Air conditioner energy consumption proved to be strongly linear as a function of the outdoor temperature as expected when taken as an aggregate. No noticeable differences in the diversity factor of the air conditioner usage were found. Analysis of the retrofit effect using PRISM yields estimates of the reduction in normalized annual consumption (NAC) and annual cooling consumption of 12% and 30%. 2 refs., 11 figs., 17 tabs.

Burns, R.; Hough, R.E. (Fleming (W.S.) and Associates, Inc., Syracuse, NY (United States))

1991-10-01T23:59:59.000Z

58

Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates  

E-Print Network [OSTI]

An experimental study was conducted to quantify the effect of return air leakage from hot/humid attic spaces on the performance of a residential air conditioner. Tests were conducted in psychrometric facilities where temperatures and humidities...

O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

1996-01-01T23:59:59.000Z

59

Central Air conditioners | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160Benin:Energy Information on PV EconomicsOregon:Centereach,conditioners Jump to:

60

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

SciTech Connect (OSTI)

In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER.

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-10-10T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Assessment of Environmentally Friendly Refrigerants for Window Air Conditioners  

SciTech Connect (OSTI)

This paper presents technical assessment of environmentally friendly refrigerants for window air conditioners that currently use refrigerant R410A for residential and commercial applications. The alternative refrigerants that are studied for its replacement include R32, R600a, R290, R1234yf, R1234ze and a mixture of R32 (90% molar concentration) and R125 (10% molar concentration). Baseline experiments were performed on a window unit charged with R410A. The ORNL Heat Pump Design Model was calibrated with the baseline data and was used to assess the comparative performance of the WAC with alternative refrigerants. The paper discusses the advantages and disadvantages of each refrigerants and their suitability for window air conditioners.

Bansal, Pradeep [ORNL] [ORNL; Shen, Bo [ORNL] [ORNL

2014-01-01T23:59:59.000Z

62

Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype  

SciTech Connect (OSTI)

This report documents the design of a desiccant enhanced evaporative air conditioner (DEVAP AC) prototype and the testing to prove its performance. Previous numerical modeling and building energy simulations indicate a DEVAP AC can save significant energy compared to a conventional vapor compression AC (Kozubal et al. 2011). The purposes of this research were to build DEVAP prototypes, test them to validate the numerical model, and identify potential commercialization barriers.

Kozubal, E.; Woods, J.; Judkoff, R.

2012-04-01T23:59:59.000Z

63

The Impact of Energy Recovery on Window Air-conditioner Efficiency  

E-Print Network [OSTI]

An experimental energy recovering air-conditioner can produce fresh air exchange heat with exhaust air in the heat exchanger, which has no additional moving parts. The EER of the experimental air-conditioner (EAC) is increased by 17.4~37.3 percent...

Luo, Q.; Tang, C.; Liao, K.

2006-01-01T23:59:59.000Z

64

Development of empirical temperature and humidity-based degraded-condition indicators for low-tonnage air conditioners  

E-Print Network [OSTI]

A split-system direct-expansion air conditioner was used to empirically determine temperature and return-air humidity indicators that could detect performance degradation resulting from degraded conditions. The air conditioner test bench...

Watt, James Bonner

1997-01-01T23:59:59.000Z

65

E-Print Network 3.0 - absorption air conditioner Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rating Summary: size systems such as absorption or vapor compression air-conditioners or heat pumps, the following... degradation. There are two possible designs for adjusting the...

66

E-Print Network 3.0 - air conditioners energy Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

energy optimization tool to analyze Summary: --when an existing component (e.g., an air conditioner) fails, it must be replaced by a more efficient component (e... National...

67

Measured Impacts of Air Conditioner Condenser Shading  

E-Print Network [OSTI]

reaching the expansion valve. In theory, the efficiency of vapor compression air conditioning can be improved through two primary mechanisms associated with condenser shading: Direct shading. Incident solar radiation can pose approximately a 1,000 w...]: IEYPERAlURL COUPARlSOn A/C SHADING DP. 1 (Some): SOUR RADlAllON COUPARISON I=AYEI[Nl KYP orq=82.1 , mu=87.(22 Z=CONDEHSIR ARU AIR lEYP orq=83.8 , mox=02.858 TIME OF DAY, (hr) 9 12 15 TIME OF DAY, (hr) Figure 3. Sample daily 15-minute data for June 21...

Parker, D. S.; Barkaszi, S. F.; Sonne, J. K.

1996-01-01T23:59:59.000Z

68

Techno-Economic Analysis of Indian Draft Standard Levels for RoomAir Conditioners  

SciTech Connect (OSTI)

The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency. In support of BEE's refrigerator program, Lawrence Berkeley National Laboratory (LBNL) produced an analysis of national impacts of standards in collaboration with the Collaborative Labeling and Standards Program (CLASP). That analysis drew on LBNL's experience with standards programs in the United States, as well as many other countries. Subsequently, as part of the process for setting optimal levels for air conditioner regulations, CLASP commissioned LBNL to provide support to BEE in the form of a techno-economic evaluation of air conditioner efficiency technologies. This report describes the methodology and results of this techno-economic evaluation. The analysis consists of three components: (1) Cost effectiveness to consumers of efficiency technologies relative to current baseline. (2) Impacts on the current market from efficiency regulations. (3) National energy and financial impacts. The analysis relied on detailed and up-to-date technical data made available by BEE and industry representatives. Technical parameters were used in conjunction with knowledge about air conditioner use patterns in the residential and commercial sectors, and prevailing marginal electricity prices, in order to give an estimate of per-unit financial impacts. In addition, the overall impact of the program was evaluated by combining unit savings with market forecasts in order to yield national impacts. LBNL presented preliminary results of these analyses in May 2006, at a meeting of BEEs Technical Committee for Air Conditioners. This meeting was attended by a wide array of stakeholder, including industry representatives, engineers and consumer advocates. Comments made by stakeholders at this meeting are incorporated into the final analysis presented in this report. The current analysis begins with the Rating Plan drafted by BEE in 2006, along with an evaluation of the market baseline according to test data submitted by manufacturers. MEPS, label rating levels, and baseline efficiencies are presented in Section 2. First, we compare Indian MEPS with current standards in other countries, and assess their relative stringency. Baseline efficiencies are then used to estimate the fraction of models likely to remain on the market at each phase of the program, and the impact on market-weighted efficiency levels. Section 3 deals with cost-effectiveness of higher efficiency design options. The cost-benefit analysis is grounded in technical parameters provided by industry representatives in India. This data allows for an assessment of financial costs and benefits to consumers as a result of the standards and labeling program. A Life-Cycle Cost (LCC) calculation is used to evaluate the impacts of the program at the unit level, thus providing some insight into the appropriateness of the levels chosen, and additional opportunities for further ratcheting. In addition to LCC, we also calculate payback periods, cost of conserved energy (CCE), and return on investment (ROI). Finally, Section 4 covers national impacts. This is an extension of unit level estimates in the two previous sections. Extrapolation to the national level depends on a forecast of air conditioner purchases (shipments), which we describe here. Following the cost-benefit analysis, we construct several efficiency scenarios including the BEE plan, but also considering further potential for efficiency improvement. These are combined with shipments through a stock accounting model in order to forecast air conditioner energy consumption in each sc

McNeil, Michael A.; Iyer, Maithili

2007-03-01T23:59:59.000Z

69

Common Air Conditioner Problems | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehicles » AlternativeUp HomeHorse Backwards | DepartmentCommon Air

70

Maintaining Your Air Conditioner | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehicles »Exchange Visitorsfor Shade LandscapingMaintaining Your Air

71

Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications: Preprint  

SciTech Connect (OSTI)

A novel liquid-desiccant air conditioner that dries and cools building supply air will transform the use of direct-contact liquid-desiccant systems in HVAC applications, improving comfort, air quality, and providing energy-efficient humidity control.

Lowenstein, A.; Slayzak, S.; Kozubal, E.

2006-07-01T23:59:59.000Z

72

Central Air Conditioner Enforcement Policy Statement | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energyon ArmedWaste andAccessCO2 Injection Begins inCarmineCentral Air Conditioner

73

Problem Type Problem Type Description Air Conditioning Air conditioner not working, leaking, etc  

E-Print Network [OSTI]

Problem Type Problem Type Description Air Conditioning Air conditioner not working, leaking, etc, Microfridges Doors and Hardware Door repair/replace Lock, latch or hinge repair, key stuck; Lost or stolen key, repair or replace Shades/Blinds Window treatment - repair or replace Washer/Dryer Washer/Dryer repair

Tennessee, University of

74

An Evaluation of Steady-State Dehumidification Characteristics of Residential Central Air Conditioners, Final Report  

E-Print Network [OSTI]

Conditioners, Air Source HeatPumps, and Sound-Rated Outdoor Unitary Equipment that ARI publishes twice a yearCl], In addition to the ARI certification, many manufacturerspublish detailed performance (capacity, efficiency, and dehumidification) data....2 - Performance and hardware data collectedfor this survey. 3.2 References 1. "Directory of Certified Unitary Air Conditioners, Air Source HeatPumps, and Sound-Rated Outdoor Unitary Equipment", Semi-Annual Issues, Air Conditioning and Refrigeration Institute...

O'Neal, D. L.; Chan, N.; Somasundaram, S.; Katipamula, S.

1987-01-01T23:59:59.000Z

75

E-Print Network 3.0 - air conditioners water Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Moving the Market toward High Efficiency Summary: and water source air conditioners and heat pumps <135,000 Btuh and for large commercial packaged water... h and <135,000 Btuh...

76

Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations  

SciTech Connect (OSTI)

This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost effective equipment upgrade opportunities and efficiency improvements in residential buildings.

Cutler, D.; Winkler, J.; Kruis, N.; Christensen, C.; Brendemuehl, M.

2013-01-01T23:59:59.000Z

77

A Preliminary Evaluation of Alternative Liquid Desiccants for a Hybrid Desiccant Air Conditioner  

E-Print Network [OSTI]

and the condenser of a vapor-compression air conditioner. The liquid desiccants studied were lithium chloride, lithium bromide, calcium chloride, and triethylene glycol. Each candidate desiccant was subjected to a screening process which weighed the merits...

Studak, J. W.; Peterson, J. L.

1988-01-01T23:59:59.000Z

78

E-Print Network 3.0 - automobile air conditioners Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Search Powered by Explorit Topic List Advanced Search Sample search results for: automobile air conditioners Page: << < 1 2 3 4 5 > >> 1 7-55E An office that is being cooled...

79

The Impact of Residential Air Conditioner Charging and Sizing on Peak Electrical Demand  

E-Print Network [OSTI]

of laboratory tests of a three-ton, capillary tube expansion, split-system air conditioner, system capacity and efficiency data available from manufacturer's literature, and assumptions about relative sizing of the equipment to cooling load on a residence. A...

Neal, L.; O'Neal, D. L.

80

Modeling the effects of Refrigerant Charging on Air Conditioner Performance Characteristics For Three Expansion Devices  

E-Print Network [OSTI]

An experimental and analytical study concerned with the off-design refrigerant charging of air conditioners is presented. A series of experiments were conducted to characterize the effects of refrigerant charge and type of expansion device...

Farzad, Mohsen

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Truman STaTe univerSiTyWELCOME HOME! Air Conditioner  

E-Print Network [OSTI]

air conditioner requests.If you need air conditioning and are assigned to Centennial,Grim,or Fair,Missouri Hall,Ryle Hall and West Campus Suites have air conditioning included).The documentation must that requires the need for air conditioning. Please fill out the form on the reverse side of this sheet, attach

Gering, Jon C.

82

Swozzle based burner tube premixer including inlet air conditioner for low emissions combustion  

DOE Patents [OSTI]

A burner for use in a combustion system of a heavy-duty industrial gas turbine includes a fuel/air premixer having an air inlet, a fuel inlet, and an annular mixing passage. The fuel/air premixer mixes fuel and air into a uniform mixture for injection into a combustor reaction zone. The burner also includes an inlet flow conditioner disposed at the air inlet of the fuel/air premixer for controlling a radial and circumferential distribution of incoming air. The pattern of perforations in the inlet flow conditioner is designed such that a uniform air flow distribution is produced at the swirler inlet annulus in both the radial and circumference directions. The premixer includes a swozzle assembly having a series of preferably air foil shaped turning vanes that impart swirl to the airflow entering via the inlet flow conditioner. Each air foil contains internal fuel flow passages that introduce natural gas fuel into the air stream via fuel metering holes that pass through the walls of the air foil shaped turning vanes. By injecting fuel in this manner, an aerodynamically clean flow field is maintained throughout the premixer. By injecting fuel via two separate passages, the fuel/air mixture strength distribution can be controlled in the radial direction to obtain optimum radial concentration profiles for control of emissions, lean blow outs, and combustion driven dynamic pressure activity as machine and combustor load are varied.

Tuthill, Richard Sterling (Bolton, CT); Bechtel, II, William Theodore (Scotia, NY); Benoit, Jeffrey Arthur (Scotia, NY); Black, Stephen Hugh (Duanesburg, NY); Bland, Robert James (Clifton Park, NY); DeLeonardo, Guy Wayne (Scotia, NY); Meyer, Stefan Martin (Troy, NY); Taura, Joseph Charles (Clifton Park, NY); Battaglioli, John Luigi (Glenville, NY)

2002-01-01T23:59:59.000Z

83

Effect of refrigerant charge, duct leakage, and evaporator air flow on the high temerature performance of air conditioners and heat pumps.  

E-Print Network [OSTI]

??An experimental study was conducted to quantify the effect of several installation items on the high outdoor ambient temperature performance of air conditioners. These installation… (more)

Rodriguez, Angel Gerardo

2012-01-01T23:59:59.000Z

84

Air Conditioner Efficiency Under Hot Dry and Hot Humid Conditions - The Utility Perspective  

E-Print Network [OSTI]

Air Conditioner Efficiency under Hot Dry and Hot Humid Conditions - The Utility Perspective Ammi Amarnath Technical Leader, Energy Efficiency & Demand Response Program Electric Power Research Institute 3420 Hillview Avenue Palo Alto, CA... are summarized below. Recommendations ? Establish a utility and energy efficiency agency coordinating council for regional standards; ? Identify regional centers to provide the institutional support; ? Develop recommended best practices for regionally based...

Amarnath, A.

85

7-55E An office that is being cooled adequately by a 12,000 Btu/h window air-conditioner is converted to a computer room. The number of additional air-conditioners that need to be installed is to be determined.  

E-Print Network [OSTI]

7-20 7-55E An office that is being cooled adequately by a 12,000 Btu/h window air-conditioner is converted to a computer room. The number of additional air-conditioners that need to be installed/h. Then noting that each available air conditioner provides 4,000 Btu/h cooling, the number of air- conditioners

Bahrami, Majid

86

The Influence of Operating Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner  

E-Print Network [OSTI]

A field investigation was carried out in an office building of Changsha city in winter and summer, the influence of different running modes, curtain styles and room temperature set point on energy consumption of room air conditioner (RAC...

Yu, J.; Yang, C.; Guo, R.; Wu, D.; Chen, H.

2006-01-01T23:59:59.000Z

87

Energy Consumption Estimation for Room Air-conditioners Using Room Temperature Simulation with One-Minute Intervals  

E-Print Network [OSTI]

For the purpose of developing optimized control algorithm for room air-conditioners to ensure their energy efficiency, a short time interval (i.e., one minute) simulation of building thermal performance is necessary because the sampling time...

Wang, F.; Yoshida, H.; Matsumoto, K.

2006-01-01T23:59:59.000Z

88

Simulation of Dehumidification Characteristics of High Efficiency Residential Central Air-Conditioners in Hot and Humid Climates  

E-Print Network [OSTI]

This study assesses the dehumidifying performance of the high efficiency residential central air conditioners (CAC) in hot/humid climates typified by that of Houston and Galveston. The performance study is based on such factors as: (i) weather (ii...

Katipamula, S.; O'Neal, D.; Somasundram, S.

1988-01-01T23:59:59.000Z

89

Effects of system cycling, evaporator airflow, and condenser coil fouling on the performance of residential split-system air conditioners  

E-Print Network [OSTI]

EFFECTS OF SYSTEM CYCLING, EVAPORATOR AIRFLOW, AND CONDENSER COIL FOULING ON THE PERFORMANCE OF RESIDENTIAL SPLIT-SYSTEM AIR CONDITIONERS A Thesis by JEFFREY BRANDON DOOLEY Submitted to the Office of Graduate Studies... COIL FOULING ON THE PERFORMANCE OF RESIDENTIAL SPLIT-SYSTEM AIR CONDITIONERS A Thesis by JEFFREY BRANDON DOOLEY Submitted to Texas A&M University in partial fulfillment of the requirements for the degree of MASTER...

Dooley, Jeffrey Brandon

2005-02-17T23:59:59.000Z

90

STRATEGIC PLAN TO REDUCE THE ENERGY IMPACT OF AIR CONDITIONERS  

E-Print Network [OSTI]

Acknowledgements This report represents the efforts of many experts from the air conditioning industry who Manufacturer Freus Air Conditioning Jim Bazemore Consultant Energy Market Innovations, Inc. Doug Beaman of Heating and Air Conditioning Industries Kahn Air Conditioning Tav Commins Staff, Buildings

91

13 SEER Standard for Central Air Conditioners and Heat Pumps (released in AEO2005)  

Reports and Publications (EIA)

In January 2004, after years of litigation in a case that pitted environmental groups and Attorneys General from 10 states against the U.S. Secretary of Energy, the U.S. Court of Appeals for the Second Circuit reestablished the central air conditioner and heat pump standard originally set in January 200. The Courts ruling, which struck down a May 2002 rollback of the 2001 standard to a 12 Seasonal Energy Efficiency Ratio (SEER) mandates that all new central air conditioners and heat pumps meet a 13 SEER standard by January 2006, requiring a 30% increase in efficiency relative to current law. The Annual Energy Outlook 2005 reference case incorporates the 13 SEER standard as mandated by the Courts ruling.

2005-01-01T23:59:59.000Z

92

Cromer Cycle Air Conditioner: A Study to Confirm Target Performance  

E-Print Network [OSTI]

The Cromer cycle uses a desiccant wheel operating in conjunction with a typical air conditioning system. Simulations and laboratory prototypes demonstrate that the cycle has the potential for enhanced humidity control with sensible heat ratios...

Cromer, C. J.

2001-01-01T23:59:59.000Z

93

DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air...  

Broader source: Energy.gov (indexed) [DOE]

Minimum Appliance Standards DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards June 3, 2010 - 2:17pm Addthis...

94

Effect of refrigerant charge, duct leakage, and evaporator air flow on the high temerature performance of air conditioners and heat pumps  

E-Print Network [OSTI]

An experimental study was conducted to quantify the effect of several installation items on the high outdoor ambient temperature performance of air conditioners. These installation items were: improper amount of refrigerant charge, reduced...

Rodriguez, Angel Gerardo

2012-06-07T23:59:59.000Z

95

Model-Based Commissioning for Filters in Room Air Conditioners  

E-Print Network [OSTI]

This paper proposes a model that can estimate filter resistance. Two sorts of value are used as inputs to estimate filter resistance. One is the power consumed by the fan in the indoor unit and the other is the thermal performance. For the room air...

Wang, F.; Yoshida, H.; Kitagawa, H.; Matsumoto, K.; Goto, K.

2004-01-01T23:59:59.000Z

96

Desiccant Moisture Exchange for Dehumidification Enhancement of Air Conditioners  

E-Print Network [OSTI]

* -led use of this inprarrPd air mtianer cycle with dssicrants will met likely occur in the cammrcial sector bbm desiccants are acmnonly IaKWn end the potential for savimy is greatar. Cne patential amnercial a~plication where the humidity pmblm...

Cromer, C. J.

1988-01-01T23:59:59.000Z

97

Measure Guideline: Air Conditioner Diagnostics, Maintenance, and Replacement  

SciTech Connect (OSTI)

This guideline responds to the need for an efficient means of identifying, diagnosing, and repairing faults in air conditioning systems in existing homes that are undergoing energy upgrades. Inadequate airflow due to constricted ducts or undersized filters, improper refrigerant charge, and other system defects can be corrected at a fraction of the cost of equipment replacement and can yield significant savings. The guideline presents a two-step approach to diagnostics and repair.

Springer, D.; Dakin, B.

2013-03-01T23:59:59.000Z

98

Covered Product Category: Room Air Conditioners | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top FiveDepartmentfor EngineeringDepartment| Department of EnergyRoom Air

99

2014-05-05 Issuance: Test Procedure for Portable Air Conditioners; Notice of Data Availability  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register notice of data availabilty regarding test procedures for portable air conditioners, as issued by the Deputy Assistant Secretary for Energy Efficiency on May 5, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

100

Cromer Cycle Air Conditioner: A Unique Air-Conditioner Desiccant Cycle to Enhance Dehumidification and Save Energy  

E-Print Network [OSTI]

-Enhanced Cooling and Dehumidification System," ASBRAE Transactions 1994, V.100, Pt. 2, #3816, American Society of Heating, Refrigeration and Air Conditioning Engineers, Atlanta, GA, 1994 [7] Chant, E. E., Transient and Stearj, State Simulations of an Advanced..., the Electric Power Research Institute (EPRI) estimate from their surveys that 30% of their customers use dehumidifiers. [1] In supermarkets, where much of the sensible cooling is already done by the display cases, wasteful overcooling is done...

Cromer, C. J.

2000-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Energy Impacts of Oversized Residential Air Conditioners -- Simulation Study of Retrofit Sequence Impacts  

SciTech Connect (OSTI)

This research addresses the question of what are the energy consequences for oversizing of an air conditioner in a home. Conventional wisdom holds that oversizing the AC results in significant energy penalties. However, the reason for this was shown to be due to crankcase heaters and not due to cycling performance of the AC, and is only valid for a particular set of assumptions. Adding or removing individual characteristics, such as ducts or crankcase heaters, can have measurable impacts on energy use. However, with all other home characteristics held constant, oversizing the AC generally has a small effect on cooling energy use, even if the cycling performance of the unit is poor. The relevant aspects of air conditioner modeling are discussed to illustrate the effects of the cycling loss coefficient, Cd, capacity, climate, ducts and parasitic losses such as crankcase heaters. A case study of a typical 1960's vintage home demonstrates results in the context of whole building simulations using EnergyPlus.

Booten, C.; Christensen, C.; Winkler, J.

2014-11-01T23:59:59.000Z

102

Conservation Division regiulations for appliance-efficiency standards relating to refrigerators and freezers, room air conditioners, central air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances  

SciTech Connect (OSTI)

The text of the appliance efficiency standards for certain types of new appliances sold in California is presented. Specifications and test methods to identify complying refrigerators, freezers, air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances are covered.

Not Available

1981-12-16T23:59:59.000Z

103

Energy savings and economics of advanced control strategies for packaged air conditioners with gas heat  

SciTech Connect (OSTI)

This paper presents an evaluation of the potential energy savings from adding advanced control to existing packaged air conditioners. Advanced control options include air-side economizer, multi-speed fan control, demand control ventilation and staged cooling. The energy and cost savings from the different control strategies individually and in combination are estimated using the EnergyPlus detailed energy simulation program for four building types, namely, a small office building, a stand-alone retail building, a strip mall building and a supermarket building. For each of the four building types, the simulation was run for 16 locations covering all 15 climate zones in the U.S. The maximum installed cost of a replacement controller that provides acceptable payback periods to owners is estimated.

Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

2013-10-01T23:59:59.000Z

104

EA-1892: Direct Final Rule Energy Conservation Standards for Residential Furnaces and Residential Central Air Conditioners & Heat Pumps  

Broader source: Energy.gov [DOE]

This EA evaluates the environmental impacts of a proposal to adopt energy conservation standards for various consumer products and certain commercial and industrial equipment, including residential furnaces and residential air conditioners and heat pumps, as required by the Energy Policy and Conservation Act, as amended (42 U.S.C. 6291 et seq.)

105

Modeling of a second-generation solar-driven Rankine air conditioner. Final report  

SciTech Connect (OSTI)

Ten configurations of a second-generation (2G), solar-powered, Rankine-driven air conditioner were simulated and the data presented for use in companion studies. The results of the analysis show that the boiling-in-collector (BIC) configuration generates more power per collector area than the other configurations. The models used to simulate the configuration are presented in this report. The generated data are also presented. Experimental work was done under this study to both improve a novel refrigerant and oil lubrication system for the centrifugal compressor and investigate the aerodynamic unloading characteristics of the centrifugal compressor. The information generated was used to define possible turbo-gearbox configurations for use in the second generation computer simulation.

Denius, M.W.; Batton, W.D.

1984-07-01T23:59:59.000Z

106

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

SciTech Connect (OSTI)

This report describes an analysis of the economic impacts of possible energy efficiency standards for commercial unitary air conditioners and heat pumps on individual customers in terms of two metrics: life-cycle cost (LCC) and payback period (PBP). For each of the two equipment classes considered, the 11.5 EER provides the largest mean LCC savings. The results show how the savings vary among customers facing different electricity prices and other conditions. At 11.5 EER, at least 80% of the users achieve a positive LCC savings. At 12.0 EER, the maximum efficiency analyzed, mean LCC savings are lower but still positive. For the {ge} $65,000 Btu/h to <135,000 Btu/h equipment class, 59% of users achieve a positive LCC savings. For the $135,000 Btu/h to <240,000 Btu/h equipment class, 91% of users achieve a positive LCC savings.

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-03-31T23:59:59.000Z

107

Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners  

E-Print Network [OSTI]

of energy storage and water heater all year round”, Energyof thermal energy storage and water heaters to ensure theair conditioner, water heater and energy storage device is

Shah, Nihar

2014-01-01T23:59:59.000Z

108

2014-03-06 Issuance: Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps; Notice of Proposed Rulemaking  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register notice of proposed rulemaking regarding test procedures for packaged terminal air conditioners and packaged terminal heat pumps, as issued by the Deputy Assistant Secretary on March 6, 2014.

109

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

E-Print Network [OSTI]

Central Air Conditioners and Heat Pumps Energy ConservationW.R. Coleman. 1990. “Heat Pump Life and Compressor LongevityC.C.. 1990. “Predicting Future Heat Pump Production Volume

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-01-01T23:59:59.000Z

110

Modeled and measured effects of compressor downsizing in an existing air conditioner/heat pump in the cooling mode  

SciTech Connect (OSTI)

It is not uncommon to find oversized central air conditioners in residences. HVAC contractors sometimes oversize central air conditioners for one reason or another--some to the point that they may be 100% larger than needed to meet the load. Retrofit measures done to improve house envelope and distribution system efficiency also contribute to HVAC oversizing, as they reduce house heating and cooling loads. Proper sizing of an air conditioner or heat pump allows more efficient operation and provides a more comfortable environment than a highly oversized unit. Another factor that lowers operating efficiency is an improper refrigerant charge. Field inspections have revealed that about half of the units checked were not properly charged. An option available to homeowners with oversized air conditioners is to replace the existing compressor with a smaller, more efficient compressor, rather than purchasing a new, smaller unit. Such a retrofit may be economically justified, especially during a compressor failure, provided the oversizing of the existing unit is not too great. A used, 15-year old, single-package heat pump with a capillary tube expansion device on the indoor coil was purchased and tested in a set of environmental chambers to determine its cooling performance at various conditions. The system was also modeled to estimate its existing performance, and that with two different types of retrofitted state-of-the-art (SOA) efficient compressors with about 30% less capacity than the original compressor. This reduced the overall system cooling capacity by about 25%. Modeling estimated that the retrofit would increase system EER at 95 F by 30%, SEER by 34%, and reduce power demand by 39% compared to the existing unit. Reduced cycling losses account for the higher increase in SEER.

Levins, W.P.; Rice, C.K.; Baxter, V.D.

1996-05-01T23:59:59.000Z

111

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India  

SciTech Connect (OSTI)

The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptive frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.

McNeil, Michael A.; Iyer, Maithili

2009-05-30T23:59:59.000Z

112

An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with a Thermal Expansion Valve  

E-Print Network [OSTI]

by the manufacturer for a specific indoor and outdoor temperatures. Once the full charge was determined, the unit was subjected to 40%, 30%, 20%, 15%, 10%, and 5% undercharging and 5%, 10%, 15%, and 20% overcharging of refrigerant by mass. The fully charged tests were... CONDITION All tests were performed on a split system central air conditioner provided by the Trane company. To determine the proper amount of refrigerant charge needed in the system and the unit's corresponding performance, charging specifications...

Farzad, M.; O'Neal, D. L.

1989-01-01T23:59:59.000Z

113

Performance characteristics of a turbo expander substituted for expansion valve on air-conditioner  

SciTech Connect (OSTI)

An experimental study is conducted on a small turbo expander which could be applied to the expansion process in place of expansion valves in refrigerator or air-conditioner to improve the cycle efficiency by recovering energy from the throttling process. The operating gas is HFC134a and the maximum cooling capacity of experiment apparatus is 32.7 kW. Four different turbo expanders are tested to find the performance characteristics of the turbo expander when they operate at a low partial admission rate. The partial admission rate is 1.70% or 2.37, and expanders are operated in the supersonic flow. In the experiment, pressure and temperature are measured at 10 different locations in the experimental apparatus. In addition to these measurements, output power at the turbo expander is measured through a generator installed on a rotor shaft with the rotational speed. Performance data of the turbo expander are obtained at many part load operations by adjusting the output power of the generator. A maximum of 15.8% total-to-static efficiency is obtained when the pressure ratio and the partial admission ratio are 2.37 and 1.70%, respectively. Experimental results show that the optimal velocity ratio decreases when the pressure ratio is decreased, and peak efficiencies, which are obtained at locally maximized efficiency depending on the operating condition, vary linearly against the subcooling temperature or the pressure ratio. (author)

Cho, Soo-Yong [Department of Mechanical and Aerospace Engineering (ReCAPT), Gyeongsang National University, 900 Gajoa-dong, Jinju 660-701 (Korea); Cho, Chong-Hyun [School of Mechanical and Aerospace Engineering, Gyeongsang National University, 900 Gajoa-dong, Jinju 660-701 (Korea); Kim, Chaesil [Department of Mechanical Engineering, Changwon National University, 9 Sarim-dong, Changwon 641-773 (Korea)

2008-09-15T23:59:59.000Z

114

Are You Planning to Bring an Air Conditioner? Welcome to Truman State University and the services available through the Disability Services Office. Part of  

E-Print Network [OSTI]

conditioner requests. If you need air conditioning and are assigned to Centennial, Grim, or Fair Apartments, Missouri Hall, Ryle Hall, and West Campus Suites have air conditioning included). The documentation must that requires the need for air conditioning. Please fill out the form on the reverse side of this sheet, attach

Gering, Jon C.

115

E-Print Network 3.0 - air-conditioners furnaces air Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Residential Space Summary: and electricity. These include boilers and furnaces for heating, air-conditioning systems and heat-pump systems... ) Space Heating Only Furnaces:...

116

The Effect of Reduced Evaporator Air Flow on the Performance of a Residential Central Air Conditioner  

E-Print Network [OSTI]

This paper discusses the measured degradation in performance of a residential air conditioning system operating under reduced evaporator air flow. Experiments were conducted using a R-22 three-ton split-type cooling system with a short-tube orifice...

Palani, M.; O'Neal, D.; Haberl, J.

117

DOE Takes Action to Stop the Sales of Air-Con Air Conditioner...  

Energy Savers [EERE]

12CO09EV12EV. Today's notice proposes the maximum penalty for selling non-compliant products and requires Air-Con to immediately cease further U.S. sales and provide written...

118

An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with Capillary Tube Expansion  

E-Print Network [OSTI]

of the coil was 20.94 ft2 with refrigerant tube sizes of 3/8". The outdoor fan was located on the top of the outdoor coil. The fan specifications are given in Table 3.1. Figure 3.3 - Detail of Outdoor Test Section 25 Table 3.1 - Fan Specification...ESL-TR-88/07-01 AN EVALUATION OF IMPROPER REFRIGERANT CHARGE ON THE PERFORMANCE OF A SPLIT SYSTEM AIR CONDITIONER WITH CAPILLARY TUBE EXPANSION FINAL REPORT Submitted by Mohsen Farzad Dennis L. O'Neal Prepared For ENERGY SYSTEMS LABORATORY RESEARCH...

Farzad, M.; O'Neal, D. L.

1988-01-01T23:59:59.000Z

119

Experimental analysis of a window air conditioner with a R-22 and R32/R125/R134a mixture  

SciTech Connect (OSTI)

Much experimental and theoretical analysis of potential R-22 replacements has been accomplished. However, published information about the experimental analysis of any off-the-shelf air conditioner with a potential R-22 replacement at realistic, operating conditions is still rare. This type of work could be useful because it provides baseline data for comparing the performance of R-22 and its potential replacement at drop-in conditions. In this study, an off-the-shelf window air conditioner was tested at Air Conditioning and Refrigeration Institute (ARI)-rated indoor conditions and at different ambient temperatures, including the ARI-rated outdoor condition, with R-22 and with its potential replacement, a ternary mixture of R-32(30%)/R-125(10%)/R-134a(60%) (the ternary mixture). A test rig was built that provided for baseline operation and for the option of operating the system with a flooded evaporator by means of liquid over-feeding (LOF). The test results indicated the cooling capacity of the ternary mixture was 7.7% less than that of R-22 at 95{degrees}F ambient for baseline operation. The cooling capacity for both refrigerants improved when a flooded evaporator, or LOF, was used. For LOF operation, the cooling capacity of the ternary mixture was only 1.1% less than that of R-22. The ternary mixture had slightly higher compressor discharge pressure, a lower compressor discharge temperature, slightly lower compressor power consumption, and a higher compressor high/low pressure ratio.

Mei, V.C.; Chen, F.C.; Chen, D.T. [Oak Ridge National Lab., TN (United States); HuangFu, E.P. [USDOE, Washington, DC (United States)

1995-07-01T23:59:59.000Z

120

The Explorationon the Energy Saving Potential of an Innovative Dual-temperature Air Conditioner and the Mechanism of the Theoretical Mixed Refrigeration Cycl  

E-Print Network [OSTI]

The Exploration on the Energy Saving Potential of an Innovative Dual-temperature Air Conditioner and the Mechanism of the Theoretical Mixed Refrigeration Cycle Zhao Lei, Zhao Xijin, Hu Andu Professor, graduate student, graduate student...-temperature air conditioning system and its corresponding theoretical mixed refrigeration cycle are proposed. This consists of a separate air handling unit and a metal radiation panel as the dual-temperature evaporators, a compressor, a condenser, two thermal...

Zhao,L.; Zhao,X.; Hu,A.

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

E-Print Network 3.0 - ac line conditioners Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AND NEXT GENERATION Summary: ... xvi Adsorption Heat Pumps and Air Conditioners ... xvi Absorption Chillers......

122

E-Print Network 3.0 - array power conditioner Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AND NEXT GENERATION Summary: ... xvi Adsorption Heat Pumps and Air Conditioners ... xvi Absorption Chillers......

123

Applying a Domestic Water-cooled Air-conditioner in Subtropical Cities  

E-Print Network [OSTI]

Water-cooled air-conditioning systems (WACS) are in general more energy efficient than air-cooled air-conditioning systems (AACS), especially in subtropical climates where the outdoor air is hot and humid. Related studies focused on evaluating...

Lee, W.; Chen, H.

2006-01-01T23:59:59.000Z

124

Improving Best Air Conditioner Efficiency by 20-30% through a High Efficiency Fan and Diffuser Stage Coupled with an Evaporative Condenser Pre-Cooler  

SciTech Connect (OSTI)

The Florida Solar Energy Center (FSEC) conducted a research project to improve the best residential air conditioner condenser technology currently available on the market by retrofitting a commercially-available unit with both a high efficiency fan system and an evaporative pre-cooler. The objective was to integrate these two concepts to achieve an ultra-efficient residential air conditioner design. The project produced a working prototype that was 30% more efficient compared to the best currently-available technologies; the peak the energy efficiency ratio (EER) was improved by 41%. Efficiency at the Air-Conditioning and Refrigeration Institute (ARI) standard B-condition which is used to estimate seasonal energy efficiency ratio (SEER), was raised from a nominal 21 Btu/Wh to 32 Btu/Wh.

Parker, Danny S; Sherwin, John R; Raustad, Richard

2014-04-10T23:59:59.000Z

125

Cornell's (LSC) project began providing 16,000 tons of cooling (1 ton of cooling = 12,000 Btu/hr, or approximately one large residential window air conditioner) to Cornell University's Ithaca  

E-Print Network [OSTI]

window air conditioner) to Cornell University's Ithaca campus in July of 2000. This project has almost completely replaced mechanical refrigeration for the Cornell district cooling system with the following benefits: · Greater LSC has replaced

Keinan, Alon

126

E-Print Network 3.0 - air conditioner utilizing Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

51 National Renewable Energy Laboratory (NREL) researchers enhanced this building energy optimization tool to analyze Summary: --when an existing component (e.g., an air...

127

An Investigation of Alternative Methods for Measuring Static Pressure of Unitary Air Conditioners and Heat Pumps  

E-Print Network [OSTI]

This project was created to address an important issue currently faced by test facilities measuring static pressure for air-conditioning and heat pumps. Specifically, ASHRAE Standard 37, the industry standard for test setup, requires an outlet duct...

Wheeler, Grant Benson

2013-08-12T23:59:59.000Z

128

Fault detection methods for vapor-compression air conditioners using electrical measurements  

E-Print Network [OSTI]

(cont.) This method was experimentally tested and validated on a commercially available air handler and duct system. In the second class of faults studied, liquid refrigerant, rather than vapor, enters the cylinder of a ...

Laughman, Christopher Reed.

2008-01-01T23:59:59.000Z

129

Investigations on Vapour Compression Air Conditioner with Direct Contact Desiccant Loop over Condenser and Evaporator  

E-Print Network [OSTI]

Perceived air quality increases when relative humidity is decreased till about 30% in the range of comfort temperature. In the present scenario, humidity is considered as a pollutant. Hence, a controlled environment not only at low temperature...

Maiya, M. P.; Ravi, J.; Tiwari, S.

2010-01-01T23:59:59.000Z

130

Testing and Economic Evaluation of a High Efficiency 10-ton Rooftop Air Conditioner  

E-Print Network [OSTI]

In 1993, the U.S. Environmental Protection Agency initiated a project to design, build and demonstrate a high efficiency commercial rooftop air conditioning unit. The unit was designed by Hibberd Consulting of Westminster, Colorado, and was built...

O'Neal, D. L.; Davis, M. A.

2006-11-09T23:59:59.000Z

131

Monitoring the Performance of a Residential Central Air Conditioner under Degraded Conditions on a Test Bench  

E-Print Network [OSTI]

enthalpies at six locations were calculated using the refrigerant property calculation program developed by Kartsounes[26]. Air-side enthalpy, humidity and specific volume were calculated by a psychrometric program developed at the Energy Systems Laboratory... procedure based on measurement of refrigerant and air side temperatures. n TABLE OF CONTENTS CHAPTER Page I INTRODUCTION 1 E LITERATURE REVIEW 3 Service and failure patterns 3 Degradation studies 4 HI MODEL DEVELOPMENT 6 Theory of operation 6 Degraded...

Palani, M.; O'Neal, D. L.; Haberl, J. S.

1992-01-01T23:59:59.000Z

132

DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana. DOCUMENTSof Energy DOEDOEAVAILABLEDepartment ofHeldViolating Minimum

133

Dirty Air Conditioners: Energy Implications of Coil Fouling Jeffrey Siegel, Lawrence Berkeley National Laboratory/ UC Berkeley  

E-Print Network [OSTI]

. For typical residential heat pump and air conditioning Residential Buildings: Technologies, Design heat pump condenser coil will foul sufficiently to cause a 20 % reduction in performance over a 4 to 7 is based on a model of heat exchanger fouling that we developed specifically for residential heat

Siegel, Jeffrey

134

Dirty Air Conditioners: Energy Implications of Coil Fouling Jeffrey Siegel, Lawrence Berkeley National Laboratory/ UC Berkeley  

E-Print Network [OSTI]

. For typical residential heat pump and air conditioning #12;systems, they predict a 10 ­ 25 % average energy heat pump condenser coil will foul sufficiently to cause a 20 % reduction in performance over a 4 to 7 is based on a model of heat exchanger fouling that we developed specifically for residential heat

135

Improving the Operating Efficiency of Packaged Air Conditioners and Heat Pumps  

SciTech Connect (OSTI)

This article discusses several control strategies that can significantly reduce energy consumption associated with packaged rooftop units RTUs). Although all of the considered strategies are widely used in built-up air-handing units, they are not commonly used in existing RTUs. Both simulation and field evaluations show that adding these control strategies to existing RTUs can reduce their energy consumption by between 30% and 60%.

Katipamula, Srinivas; Wang, Weimin; Vowles, Mira

2014-03-10T23:59:59.000Z

136

2015-02-12 Issuance: Test Procedures for Portable Air Conditioners; Notice  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustionImprovement3 Beryllium-Associated Worker2014 HouseCoveredAirDepartment ofof04of Proposed

137

2015-02-13 Issuance: Energy Conservation Standards for Portable Air Conditioners; Notice of Public Meeting and Availability of the Preliminary Technical Support Document  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register notice of public meeting regarding energy conservation standards for portable air conditioners, as issued by the Deputy Assistant Secretary for Energy Efficiency on February 13, 2015. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

138

Analysis on the energy efficiency of variable-frequency air conditioners (Hitachi models as an example) Jim Jr-Min Lin 2014.09.26  

E-Print Network [OSTI]

Analysis on the energy efficiency of variable-frequency air conditioners (Hitachi models (Max) Energy Efficiency @min load Energy Efficiency @Max load kW kW kW kW W/W W/W RAS-22NB 1.00 3.20 0 Efficiency @min load Energy Efficiency @Max load kW kW kW kW W/W W/W RAM-5FNS(B) - 12.5 - 2.91 - 4.3 RAM-6FNS

139

Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study  

SciTech Connect (OSTI)

The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The performance degradation of R410A at higher temperatures was greater than R22. However, the R22 and R410A systems both operated normally during all tests. Visual observations of the R410A system provided no indication of vibrations or TXV hunting at high ambient outdoor test conditions with the compressor operating in the transcritical regime.

Piotr A. Domanski; W. Vance Payne

2002-10-31T23:59:59.000Z

140

A Novel, Low-Cost, Reduced-Sensor Approach for Providing Smart Renote Monitoring and Diagnostics for Packaged Air Conditioners and Heat Pumps  

SciTech Connect (OSTI)

This report describes conceptually an approach to providing automated remote performance and conditioning monitoring and fault detection for air conditioners and heat pumps that shows great promise to reduce the capital and installation costs of such systems from over $1000 per unit to $200 to $400 per unit. The approach relies on non-intrusive electric load monitoring (NIELM) to enable separation of the power use signals of compressors and fans in the air conditioner or heat pump. Then combining information on the power uses and one or two air temperature measurements, changes in energy efficiency and occurrence of major faults would be detected. By decreasing the number of sensors used from between ten and twenty in current diagnostic monitoring systems to three for the envisaged system, the capital cost of the monitoring system hardware and the cost of labor for installation would be decreased significantly. After describing the problem being addressed and the concept for performance monitoring and fault detection in more detail, the report identifies specific conditions and faults that the proposed method would detect, discusses specific needs for successful use of the NIELM approach, and identifies the major elements in the path from concept to a commercialized monitoring and diagnostic system.

Brambley, Michael R.

2009-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Solar-Powered, Liquid-Desiccant Air Conditioner for Low-Electricity Humidity Control: Report and Summary Report  

SciTech Connect (OSTI)

The primary objective of this project was to demonstrate the capabilities of a new high-performance, liquid-desiccant dedicated outdoor air system (DOAS) to enhance cooling efficiency and comfort in humid climates while substantially reducing electric peak demand at Tyndall Air Force Base (AFB), which is 12 miles east of Panama City, Florida.

Dean, J.; Kozubal, E.; Herrmann, L.; Miller, J.; Lowenstein, A.; Barker, G.; Slayzak, S.

2012-11-01T23:59:59.000Z

142

Proceedings of Healthy Buildings 2009 Paper 474 Impacts of HVAC Filtration on Air-Conditioner Energy Consumption in  

E-Print Network [OSTI]

Proceedings of Healthy Buildings 2009 Paper 474 Impacts of HVAC Filtration on Air efficiency filters (Points A, B, and C, respectively). #12;Proceedings of Healthy Buildings 2009 Paper 474

Siegel, Jeffrey

143

Minimum cost air pollution control for cotton gins  

E-Print Network [OSTI]

pollution control, in order to achieve compliance with air pollution regulations, reduces the profit margin of the ginning operation. Presently, the number of viable operating gins in the U.S. has declined and the imposition of expensive controls to comply...

Flannigan, Steven Shawnacy

1997-01-01T23:59:59.000Z

144

Experimental analysis of a window air conditioner with R-22 and zeotropic mixture of R-32/125/134a  

SciTech Connect (OSTI)

This study is the result of the cooperative research and development agreement (CRADA) between Oak Ridge National Laboratory and E.I. Du Pont De Nemours and Company, Inc., (CRADA No. 92-0161) for testing the use of heat exchangers as the evaporator and condenser in an air-conditioning rig. Heat exchangers at typical realistic operating conditions were tested with R-22 and with its potential replacement, a ternary mixture of R-32(30%)/R-125(10%)/R-134a(60%). A test rig was built that provided for operation of the low-temperature exchanger (evaporator) with flooded coils. The test results indicated that the performance of the evaporator heat exchanger using ternary mixture, in terms of cooling capacity, would be around 7.4% less than the performance using R-22. The cooling capacity for both refrigerants improved with flooded evaporator operation by 8.6% for R-22 and by 15% for ternary mixture. Compared with R-22 operation, operation with ternary mixture results in slightly higher compressor discharge pressure, lower compressor discharge temperature, slightly lower compressor power consumption, and a higher compressor high-low pressure ratio. Temperature glide for ternary mixture, for both evaporator and condenser, was clearly evident, but not as pronounced as expected because of the pressure drop (and thus the temperature drop) along the coils. Further improvement of the performance of ternary mixture is possible if the evaporator is arranged in a counter-cross-flow configuration to take advantage of the temperature glide. Current evaporator designs are mostly concurrent-cross-flow, which is more appropriate for single-component refrigerants or azeotropic refrigerant mixtures.

Mei, V.C.; Chen, F.C.; Carlstedt, J.; Hallden, D.

1995-08-01T23:59:59.000Z

145

13 EER Window Air Conditioner  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up from theDepartment( Sample of Shipment Notice)1021STATE ENERGY PROGRAM

146

E-Print Network 3.0 - air-cooled water chillers Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and centrifugal chillers... ... xvi Adsorption Heat Pumps and Air Conditioners ... xvi Absorption Chillers......

147

Future Air Conditioning Energy Consumption in Developing Countries and what can be done about it: The Potential of Efficiency in the Residential Sector  

E-Print Network [OSTI]

an air conditioner for the first time, or by replacements ofair conditioner lifetime. Each retirement generates another replacementreplacements. Step 1 is described in detail in the section called Forecasting Air Conditioner

McNeil, Michael A.; Letschert, Virginie E.

2008-01-01T23:59:59.000Z

148

Future Air Conditioning Energy Consumption in Developing Countries and what can be done about it: The Potential of Efficiency in the Residential Sector  

E-Print Network [OSTI]

an air conditioner for the first time, or by replacements ofair conditioner lifetime. Each retirement generates another replacementand replacements. Step 1 is described in detail in the section called Forecasting Air Conditioner

McNeil, Michael A.; Letschert, Virginie E.

2008-01-01T23:59:59.000Z

149

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology  

SciTech Connect (OSTI)

The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

Not Available

1993-11-01T23:59:59.000Z

150

Attenuator And Conditioner  

DOE Patents [OSTI]

An apparatus and method of attenuating and/or conditioning optical energy for an optical transmitter, receiver or transceiver module is disclosed. An apparatus for attenuating the optical output of an optoelectronic connector including: a mounting surface; an array of optoelectronic devices having at least a first end; an array of optical elements having at least a first end; the first end of the array of optical elements optically aligned with the first end of the array of optoelectronic devices; an optical path extending from the first end of the array of optoelectronic devices and ending at a second end of the array of optical elements; and an attenuator in the optical path for attenuating the optical energy emitted from the array of optoelectronic devices. Alternatively, a conditioner may be adapted in the optical path for conditioning the optical energy emitted from the array of optoelectronic devices.

Anderson, Gene R. (Albuquerque, NM); Armendariz, Marcelino G. (Albuquerque, NM); Carson, Richard F. (Albuquerque, NM); Bryan, Robert P. (Albuquerque, NM); Duckett, III, Edwin B. (Albuquerque, NM); Kemme, Shanalyn Adair (Albuquerque, NM); McCormick, Frederick B. (Albuquerque, NM); Peterson, David W. (Sandia Park, NM)

2006-04-04T23:59:59.000Z

151

Homeowner's Guide to Window Air Conditioner Installation for Efficiency and Comfort (Fact Sheet), Building America Case Study: Technology Solutions for Existing Homes, Building Technologies Office (BTO)  

SciTech Connect (OSTI)

This fact sheet offers a step-by-step guide to proper installation of window air conditioning units, in order to improve efficiency and comfort for homeowners.

Not Available

2013-06-01T23:59:59.000Z

152

Potential Impact of Adopting Maximum Technologies as Minimum Efficiency Performance Standards in the U.S. Residential Sector  

E-Print Network [OSTI]

central air conditioners, water heaters and furnaces) areair conditioners, water heaters and furnaces) UnregulatedM i l l o 10 i n s 2. Water Heaters DOE has issued a final

Letschert, Virginie

2010-01-01T23:59:59.000Z

153

Development of slotted orifice flow conditioner  

E-Print Network [OSTI]

concentric rings of radial slots. The porosity of each ring varied so that the conditioner generated a six step parabolic profile similar to the profile tested with Fluent The overall porosity of the parabolic conditioner was 25. 1'/o, which is lower than... 19 Velocity Profile Procedure . Co Measurement Procedure Data Reduction . . . . . . 19 21 22 RESULTS 24 LDA Velocity Profile and Turbulence Intensity Analysis 24 Tube Bundle, Uniform Slotted Orifice Flow Conditioner . . Parabolic Slotted...

Ihfe, Larry Michael

1994-01-01T23:59:59.000Z

154

Low-noise pulse conditioner  

DOE Patents [OSTI]

A low-noise pulse conditioner is provided for driving electronic digital processing circuitry directly from differentially induced input pulses. The circuit uses a unique differential-to-peak detector circuit to generate a dynamic reference signal proportional to the input peak voltage. The input pulses are compared with the reference signal in an input network which operates in full differential mode with only a passive input filter. This reduces the introduction of circuit-induced noise, or jitter, generated in ground referenced input elements normally used in pulse conditioning circuits, especially speed transducer processing circuits.

Bird, David A. (Oak Ridge, TN)

1983-01-01T23:59:59.000Z

155

EVALUATION OF A NEW SOLAR AIR CONDITIONER  

E-Print Network [OSTI]

· Benefits to California · Overall Technology Assessment · Appendices o Appendix A: Final Report (under-16 Grant Funding: $74,547 Term: February 2001 ­ June 2003 PIER Subject Area: Renewable Energy Technologies/Agricultural/Water End-Use Energy Efficiency · Renewable Energy Technologies · Environmentally-Preferred Advanced

156

Room Air Conditioners | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehicles »ExchangeDepartmentResolve to Save Energy This Year|Rooftop

157

Tips: Air Conditioners | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas ConchasPassiveSubmittedStatusButler Tina Butler Tina-Butler.jpg Tina L.

158

Room Air Conditioners | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartment of Energy fromCommentsRevolving Loan Funds Revolving LoanA l iSoftRTU Suite

159

DOE Investigates Possible Air Conditioner Efficiency Violations |  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana. DOCUMENTSof Energy DOE ChallengeThese(Notice of Proposed

160

ROOM AIR CONDITIONER WALL MOUNTED type  

E-Print Network [OSTI]

/ 150 (76 / 68) 238 / 207 (108 / 94) REFRIGERANT CHARGING PIPE LENGTH 25 ft. (7.5 m) 33 ft. (10 m) 49 ftY3E-A C O N T E N T S SPECIFICATIONS OUTLINE AND DIMENSIONS REFRIGERANT SYSTEM DIAGRAM CIRCUIT, Induction motor, Recipro CODE H25B18QABCA H25B18QABCA H25B24QABCA H25B24QABCA H25B35QABCA REFRIGERANT R-22

Kleinfeld, David

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Future Air Conditioning Energy Consumption in Developing Countries and what can be done about it: The Potential of Efficiency in the Residential Sector  

E-Print Network [OSTI]

G. Henderson (2005) Home air conditioning in Europe – howhigher growth in Indian air conditioner saturation duringand A.A. Pavlova ( 2003). Air conditioning market saturation

McNeil, Michael A.; Letschert, Virginie E.

2008-01-01T23:59:59.000Z

162

Tips: Air Ducts | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

the walls, floors, and ceilings; it carries the air from your home's furnace and central air conditioner to each room. Ducts are made of sheet metal, fiberglass, or other...

163

Optimization of Air Conditioning Cycling  

E-Print Network [OSTI]

on a 3-ton residential air conditioner are then presented to intuitively understand the effect of expansion valve and evaporator fan cycling in a real system. A real time optimization method is explored and the feasibility, recommendations for a...

Seshadri, Swarooph

2012-10-19T23:59:59.000Z

164

Future Air Conditioning Energy Consumption in Developing Countriesand what can be done about it: The Potential of Efficiency in theResidential Sector  

SciTech Connect (OSTI)

The dynamics of air conditioning are of particular interestto energy analysts, both because of the high energy consumption of thisproduct, but also its disproportionate impact on peak load. This paperaddresses the special role of this end use as a driver of residentialelectricity consumption in rapidly developing economies. Recent historyhas shown that air conditioner ownership can grow grows more rapidly thaneconomic growth in warm-climate countries. In 1990, less than a percentof urban Chinese households owned an air conditioner; by 2003 this numberrose to 62 percent. The evidence suggests a similar explosion of airconditioner use in many other countries is not far behind. Room airconditioner purchases in India are currently growing at 20 percent peryear, with about half of these purchases attributed to the residentialsector. This paper draws on two distinct methodological elements toassess future residential air conditioner 'business as usual' electricityconsumption by country/region and to consider specific alternative 'highefficiency' scenarios. The first component is an econometric ownershipand use model based on household income, climate and demographicparameters. The second combines ownership forecasts and stock accountingwith geographically specific efficiency scenarios within a uniqueanalysis framework (BUENAS) developed by LBNL. The efficiency scenariomodule considers current efficiency baselines, available technologies,and achievable timelines for development of market transformationprograms, such as minimum efficiency performance standards (MEPS) andlabeling programs. The result is a detailed set of consumption andemissions scenarios for residential air conditioning.

McNeil, Michael A.; Letschert, Virginie E.

2007-05-01T23:59:59.000Z

165

2014-03-06 Issuance: Test Procedures for Packaged Terminal Air...  

Broader source: Energy.gov (indexed) [DOE]

Issuance: Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps; Notice of Proposed Rulemaking 2014-03-06 Issuance: Test Procedures for...

166

SOLAS Mid Term Strategy Initiative "Air-sea gas fluxes at Eastern boundary upwelling and Oxygen Minimum Zone (OMZ) systems"  

E-Print Network [OSTI]

of SOLAS and to the Workshop Véronique Garçon 09:50 Surface (energy and water) fluxes at the air1 SOLAS Mid Term Strategy Initiative "Air-sea gas fluxes at Eastern boundary upwelling and Oxygen

167

Field Measurements of Efficiency and Duct Effectiveness in Residential Forced Air Distributions Systems  

E-Print Network [OSTI]

power for air conditioning, heat pumps and electricwith 13 air conditioners, eight heat pumps (one house hadPre Post * A C : air conditioning, HP : heat pump, GF : gas

Jump, D.A.

2011-01-01T23:59:59.000Z

168

NREL Solves Residential Window Air Conditioner Performance Limitations (Fact Sheet)  

SciTech Connect (OSTI)

Comprehensive performance tests lead to enhanced modeling capability and affordable methods to increase energy efficiency.

Not Available

2013-05-01T23:59:59.000Z

169

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network [OSTI]

Engineers, Inc. , Energy Efficient Design of New BuildingsStandard 90.1, Energy Efficient Design of New Buildings

Rosenquist, G.

2010-01-01T23:59:59.000Z

170

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network [OSTI]

of Energy-Energy Information Administration, A Look atof Energy-Energy Information Administration, 1995 Commercialof Energy-Energy Information Administration, Annual Energy

Rosenquist, G.

2010-01-01T23:59:59.000Z

171

Development of a room air conditioner design model  

E-Print Network [OSTI]

AND RECOMMENDATIONS. Page . 12 . 12 . 20 . 33 . 38 . 48 . 50 . 56 Conclusions. Recommendations. REFERENCES APPENDIX A . 57 . 57 . 59 . 61 VITA . 66 LZST OP TABLES Table Page 2. 1 Major output parameters from the ORNL model 3. 1 Effect of tube.... Efficiency improvements are evaluated with the aid of a computer model. The model chosen for this analysis was the Oak Ridge National Laboratory (ORNL) heat pump model [5] . The ORNL Heat Pump Design Model is a FORTRAN computer program developed...

Penson, Steven Brad

1988-01-01T23:59:59.000Z

172

Ductless Mini-Split Air Conditioners | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehicles » AlternativeUpDrain-Water Heat Recovery Drain-Water

173

Four Central Air Conditioners Determined Noncompliant With Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecordFederal7.pdfFlash_2010_-24.pdfOverviewPlansBuildings andEfficiency

174

Commercial Air Conditioners and Heat Pumps | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTieCelebrate Earth Codesthe Natural Resources Defenseon

175

List of Central Air conditioners Incentives | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth's Heat JumpInc Place:KeystoneSolar (Texas) JumpEventBoilersCeiling FanCentral

176

List of Room Air Conditioners Incentives | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth's Heat JumpInc Place:KeystoneSolarList ofPassive SolarRoofs Incentives Jump

177

High-Efficiency Window Air Conditioners - Building America Top Innovation |  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana.ProgramJulietip sheetK-4In 2013 many| Department HIGH

178

Variable Speed Fan Retrofits for Computer Room Air Conditioners |  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomen Owned SmallOf The 2012Nuclear Guide Remote55 Jefferson Ave. Valley ForgeValue

179

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network [OSTI]

Administration, Annual Energy Outlook 2000, December, 1999.trends from EIA's Annual Energy Outlook 2000 (AE02000) were

Rosenquist, G.

2010-01-01T23:59:59.000Z

180

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana.Program - LibbyofThisStatementNOTElectricity Transmissionof EnergyEnergy

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Enforcement Policy Statement: Off Mode Standards for Central Air Conditioners  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana.Program -Department oftoTheseClickDepartment of Energy June

182

Product Standards for Air Conditioners (Japan) | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth'sOklahoma/GeothermalOrangePeru:JobInformation MccoyPrimusProEcoProcana

183

13-Energy Efficiency Ratio Window Air Conditioner | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top Five EERE Blog Posts of 2014 Year in Review:Summer-0 ResourcesEnergy

184

Covered Product Category: Residential Central Air Conditioners | Department  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top FiveDepartmentfor EngineeringDepartment ofBoilersDataHotof Energy Central

185

Variable Speed Fan Retrofits for Computer Room Air Conditioners  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage »of EnergyTheTwoVulnerabilities | Department of|VTA,anCompression

186

HEATING, AIR-CONDITIONING AND REFRIGERATION DISTRIBUTORS INTERNATIONAL...  

Broader source: Energy.gov (indexed) [DOE]

of the updated Energy Conservation Standards for Air Conditioners, Furnaces and Heat Pumps. DOE EX Parte Memo.pdf More Documents & Publications 3rd Semi-Annual Report to...

187

Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)  

SciTech Connect (OSTI)

This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

Kozubal, E.

2013-02-01T23:59:59.000Z

188

High Energy Efficiency Air Conditioning  

SciTech Connect (OSTI)

This project determined the performance of a new high efficiency refrigerant, Ikon B, in a residential air conditioner designed to use R-22. The refrigerant R-22, used in residential and small commercial air conditioners, is being phased out of production in developed countries beginning this year because of concerns regarding its ozone depletion potential. Although a replacement refrigerant, R-410A, is available, it operates at much higher pressure than R-22 and requires new equipment. R-22 air conditioners will continue to be in use for many years to come. Air conditioning is a large part of expensive summer peak power use in many parts of the U.S. Previous testing and computer simulations of Ikon B indicated that it would have 20 - 25% higher coefficient of performance (COP, the amount of cooling obtained per energy used) than R-22 in an air-cooled air conditioner. In this project, a typical new R-22 residential air conditioner was obtained, installed in a large environmental chamber, instrumented, and run both with its original charge of R-22 and then with Ikon B. In the environmental chamber, controlled temperature and humidity could be maintained to obtain repeatable and comparable energy use results. Tests with Ikon B included runs with and without a power controller, and an extended run for several months with subsequent analyses to check compatibility of Ikon B with the air conditioner materials and lubricant. Baseline energy use of the air conditioner with its original R-22 charge was measured at 90 deg F and 100 deg F. After changeover to Ikon B and a larger expansion orifice, energy use was measured at 90 deg F and 100 deg F. Ikon B proved to have about 19% higher COP at 90 deg F and about 26% higher COP at 100 deg F versus R-22. Ikon B had about 20% lower cooling capacity at 90 deg F and about 17% lower cooling capacity at 100 deg F versus R-22 in this system. All results over multiple runs were within 1% relative standard deviation (RSD). All of these values agree well with previous results and computer simulations of Ikon B performance versus R-22. The lower cooling capacity of Ikon B is not a concern unless a particular air conditioner is near its maximum cooling capacity in application. Typically, oversized A/C systems are installed by contractors to cover contingencies. In the extended run with Ikon B, which lasted about 4.5 months at 100 deg F ambient temperature and 68% compressor on time, the air conditioner performed well with no significant loss of energy efficiency. Post-run analysis of the refrigerant, compressor lubricant oil, compressor, compressor outlet tubing, and the filter/dryer showed minor effects but nothing that was considered significant. The project was very successful. All objectives were achieved, and the performance of Ikon B indicates that it can easily be retrofitted into R-22 air conditioners to give 15 - 20% energy savings and a 1 - 3 year payback of retrofit costs depending on location and use. Ikon B has the potential to be a successful commercial product.

Edward McCullough; Patrick Dhooge; Jonathan Nimitz

2003-12-31T23:59:59.000Z

189

Spring is in the Air and so is a Plethora of Pollen Dr. Joan Bradshaw, County Extension Director  

E-Print Network [OSTI]

and skin. Use air filters and clean regularly, or run an air conditioner and change the air filterSpring is in the Air and so is a Plethora of Pollen Dr. Joan Bradshaw, County Extension Director, Suite 1 Lecanto, FL 34461 Springtime is in the air in Citrus County with its glorious weather

Jawitz, James W.

190

Underfloor vs. overhead: a comparative analysis of air distribution systems using the EnergyPlus simulation software  

E-Print Network [OSTI]

ENTHALPY LIMIT, ! - ReturnAirEnthalpyLimit NO LOCKOUT, ! -Lockout FIXED MINIMUM, ! - MinimumLimit Mixed Air Node

Daly, A.

2006-01-01T23:59:59.000Z

191

King Air flight RICO 2004/12/13 page 1 King Air N2UW flight report for December 13, 2004  

E-Print Network [OSTI]

repair of the air conditioner on the aircraft, a test flight was needed and was to be transformedKing Air flight ­ RICO ­ 2004/12/13 page 1 King Air N2UW flight report for December 13, 2004 Crew: Drew, Vali, Oolman, Glover After

Vali, Gabor

192

DOE Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomentheATLANTA, GA - U.S. Department ofThe U.S.D.C. - Energy Secretary WASHINGTON,to

193

Establish the Commercial Pacakge Air Conditioners and Commercial Warm Air Furnaces WG  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up from theDepartment ofEnergy.pdfApplications: Heating Cooling OPUBLICLeadcommercial

194

Comparing Mainframe and Windows Server Transactions per kWh  

E-Print Network [OSTI]

..................................................................................................................................15 Air Conditioner (Heat Pump) Efficiency Units

Narasayya, Vivek

195

GMTI radar minimum detectable velocity.  

SciTech Connect (OSTI)

Minimum detectable velocity (MDV) is a fundamental consideration for the design, implementation, and exploitation of ground moving-target indication (GMTI) radar imaging modes. All single-phase-center air-to-ground radars are characterized by an MDV, or a minimum radial velocity below which motion of a discrete nonstationary target is indistinguishable from the relative motion between the platform and the ground. Targets with radial velocities less than MDV are typically overwhelmed by endoclutter ground returns, and are thus not generally detectable. Targets with radial velocities greater than MDV typically produce distinct returns falling outside of the endoclutter ground returns, and are thus generally discernible using straightforward detection algorithms. This document provides a straightforward derivation of MDV for an air-to-ground single-phase-center GMTI radar operating in an arbitrary geometry.

Richards, John Alfred

2011-04-01T23:59:59.000Z

196

Air conditioning system  

DOE Patents [OSTI]

An air conditioner comprises a plurality of plates arranged in a successively stacked configuration with portions thereof having a spaced apart arrangement, and defining between successive adjacent pairs of plates at the spaced apart portions a first and second series of discrete alternating passages wherein a first air stream is passed through the first series of passages and a second air stream is passed through the second series of passages; and said stacked configuration of plates forming integrally therewith a liquid delivery means for delivering from a source a sufficient quantity of a liquid to the inside surfaces of the first series of fluid passages in a manner which provides a continuous flow of the liquid from a first end to a second end of the plurality of plates while in contact with the first air stream.

Lowenstein, Andrew; Miller, Jeffrey; Gruendeman, Peter; DaSilva, Michael

2005-02-01T23:59:59.000Z

197

Department of Energy Announces Steps to Strengthen Enforcement...  

Office of Environmental Management (EM)

Completion of Critical Energy Conservation Appliance Standards DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards...

198

Rule Proposed to Prohibit Importation of Products that Fail to...  

Office of Environmental Management (EM)

DOE Adopts Rules to Improve Energy Efficiency Enforcement DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards...

199

DOE Steps Lead to Significant Increase in Compliance with Energy...  

Office of Environmental Management (EM)

Department of Energy Subpoenas Compliance Data from AeroSys, Inc. DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards...

200

Recent developments in orifice meter and flow conditioner research  

SciTech Connect (OSTI)

In 1969 concerns were raised regarding the validity of the orifice meter`s coefficient of discharge uncertainty. An effort to resolve these concerns resulted in an internationally supported research project which produced a new sharp-edged concentric orifice meter empirical database and coefficient of discharge equation. However, the new empirical database and coefficient of discharge equation did not account for all of the differences being encountered in orifice metering. And in 1986, as a derivative of the coefficient of discharge equation research, questions were raised regarding the influences of installation effects on the orifice meter`s coefficient of discharge. The 1986 EC research data indicated that the flow conditioner and straight pipe installation requirements of the flow measurement standards were inadequate to prevent biasing of the orifice meter`s coefficient of discharge by flow disturbances generated from upstream piping elements. Data generated from 1990 through 1993 by GRI sponsored SWRI and NIST research confirmed the original EC biasing and further identified differential pressure tap radial position sensitivity and velocity profile and swirl angle theory deficiencies. Current research is continuing to define installation effects influences and identify possible solutions.

LaNasa, P.J. [CPL and Associates, Houston, TX (United States)

1995-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Dynamic Performance and Control of a Multilevel Universal Power Conditioner Leon M. Tolbert, Fang Z. Peng Thomas G. Habetler  

E-Print Network [OSTI]

-to-back diode-clamped inverters that constitute the universal power conditioner. An experimental verification. To meet the objectives detailed in these new premium power agreements, the implementation of advanced- clamped inverter into a universal power conditioner is an enticing prospect. For a multilevel universal

Tolbert, Leon M.

202

Evaluation of a CFD-model for simulation of simplified flow conditioners  

SciTech Connect (OSTI)

Perforated plate flow conditioners are used to generate a fully developed turbulent flow profile upstream of an orifice meter. It is very time-consuming to measure the effect of a flow conditioner for different upstream flow profiles. Therefore a project is initiated to evaluate the performance of a computational fluid computer code for this purpose. If the code correctly predicts the flow characteristics downstream of more complex flow conditioners. In this study a k-{var_epsilon} CFD-model was used to predict the flow downstream of obstruction plates having one large or nine small holes. Both mean velocity, turbulent kinetic energy, k, and the dissipation rate of turbulent kinetic energy, {var_epsilon}, were calculated and compared against measured data. The results indicate that it is possible to predict the mean velocity well and that the accuracy of the predicted k and {var_epsilon} depends on the complexity of the flow.

Erdal, A. [Statoil/K-LAB, Haugesund (Norway); Torbergsen, L.E.; Rimestad, S.; Krogstad, P.A. [Norwegian Inst. of Technology, Trondheim (Norway)

1995-12-31T23:59:59.000Z

203

Flow conditioner for fuel injector for combustor and method for low-NO.sub.x combustor  

DOE Patents [OSTI]

An injector for a gas turbine combustor including a catalyst coated surface forming a passage for feed gas flow and a channel for oxidant gas flow establishing an axial gas flow through a flow conditioner disposed at least partially within an inner wall of the injector. The flow conditioner includes a length with an interior passage opening into upstream and downstream ends for passage of the axial gas flow. An interior diameter of the interior passage smoothly reduces and then increases from upstream to downstream ends.

Dutta, Partha; Smith, Kenneth O.; Ritz, Frank J.

2013-09-10T23:59:59.000Z

204

Study of thermoelectric technology for automobile air conditioning  

SciTech Connect (OSTI)

An analytical study was conducted to determine the feasibility of employing thermoelectric (TE) cooling technology in automobile air conditioners. The study addressed two key issues -- power requirements and availability of thermoelectric materials. In this paper, a mathematical model was developed to predict the performance of TE air conditioners and to analyze power consumption. Results show that the power required to deliver a cooling capacity of 4 kW (13,80 Btu/h) in a 38{degree}C (100{degree}F) environment will be 9.5 kW electric. Current TE modules suitable for air conditioning are made of bismuth telluride. The element tellurium is expected to be in short supply if TE cooling is widely implemented for auto air conditioning; some options available in this regard were studied and presented in this paper.

Mathiprakasam, B.; Heenan, P. (Midwest Research Inst., Kansas City, MO (United States)); Mei, V.C.; Chen, F.C. (Oak Ridge National Lab., TN (United States))

1991-01-01T23:59:59.000Z

205

Market and behavioral barriers to energy efficiency: A preliminary evaluation of the case for tariff financing in California  

E-Print Network [OSTI]

Central Air Conditioners and Heat Pumps. ” Department ofrecent central air conditioner and heat pump purchasers only

Fujita, K. Sydny

2012-01-01T23:59:59.000Z

206

Delivering Energy Efficiency to Middle Income Single Family Households  

E-Print Network [OSTI]

water heater replacement, air conditioner Assumptions behindreplacements (e.g. , furnace, water heater, air conditioner,

Zimring, Mark

2012-01-01T23:59:59.000Z

207

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network [OSTI]

water heater replacement, air conditioner replacement, solarwater heater replacement, air conditioner replacement, solar

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

208

Driving Demand for Home Energy Improvements: Motivating residential customers to invest in comprehensive upgrades that eliminate energy waste, avoid high utility bills, and spur the economy  

E-Print Network [OSTI]

replacement, air conditioner replacement, solar thermalreplacement, air conditioner replacement, solar thermal

Fuller, Merrian C.

2011-01-01T23:59:59.000Z

209

Lesson 36: Housing and Accommodation  

E-Print Network [OSTI]

/ mikeka [air conditioner / air conditioners] [mat / mats] CHUMBA CHA KULA CHAKULA / CHUMBA CHA MAANKULI

210

Classroom Vocabulary Classroom Vocabulary [msamiati wa darasani  

E-Print Network [OSTI]

] [wall clock] [map / maps] [air conditioner / air conditioners] [picture / pictures] [drawing / drawings

211

Haemers' Minimum Rank.  

E-Print Network [OSTI]

??Haemers' minimum rank was first defined by Willem Haemers in 1979. He created this graph parameter as an upper bound for the Shannon capacity of… (more)

Tims, Geoff

2013-01-01T23:59:59.000Z

212

A review of polymer-based water conditioners for reduction of handling-related injury  

SciTech Connect (OSTI)

Fish are coated with an external layer of protective mucus. This layer serves as the primary barrier against infection or injury, reduces friction, and plays a role in ionic and osmotic regulation. However, the mucus layer is easily disturbed when fish are netted, handled, transported, stressed, or subjected to adverse water conditions. Water additives containing polyvinylpyrrolidone (PVP) or proprietary polymers have been used to prevent the deleterious effects of mucus layer disturbances in the commercial tropical fish industry, aquaculture, and for other fisheries management purposes. This paper reviews research on the effectiveness of water conditioners, and examines the contents and uses of a wide variety of commercially available water conditioners. Water conditioners containing polymers may reduce external damage to fish held in containers during scientific experimentation, including surgical implantation of electronic tags. However, there is a need to empirically test the effectiveness of water conditioners at preventing damage to and promoting healing of the mucus layer. A research agenda is provided to advance the science related to the use of water conditions to improve the condition of fish during handling and tagging.

Harnish, Ryan A.; Colotelo, Alison HA; Brown, Richard S.

2011-01-01T23:59:59.000Z

213

Calendar Year 2008 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network [OSTI]

air cleaners Room air conditioners Scanners Servers Set-topBoilers • Central Air Conditioners and Air-Source HeatHeat Pump -Central Air Conditioner -Gas Furnace -Oil

Homan, GregoryK

2010-01-01T23:59:59.000Z

214

Theoretical Minimum Energy Use of a Building HVAC System  

E-Print Network [OSTI]

This paper investigates the theoretical minimum energy use required by the HVAC system in a particular code compliant office building. This limit might be viewed as the "Carnot Efficiency" for HVAC system. It assumes that all ventilation and air...

Tanskyi, O.

2011-01-01T23:59:59.000Z

215

The Minimum Price Contract  

E-Print Network [OSTI]

A minimum price contract is one of many tools a marketer may use to better manage price and production risk while trying to achieve financial goals and objectives. This publication discusses the advantages and disadvantages involved...

Waller, Mark L.; Amosson, Stephen H.; Welch, Mark; Dhuyvetter, Kevin C.

2008-10-17T23:59:59.000Z

216

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

L ABORATORY China Energy Efficiency Round Robin TestingNeed to Improve the Energy Efficiency of Energy Consumingfor Implementing the China Energy Efficiency Label System (

Zhou, Nan

2010-01-01T23:59:59.000Z

217

Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners  

E-Print Network [OSTI]

its integration. In the DOE’s energy model which was used toSources The energy efficiency simulation model used in thiss Bottom Up Energy Analysis System (BUENAS) model (McNeil et

Shah, Nihar

2014-01-01T23:59:59.000Z

218

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network [OSTI]

the current cost of production of 3.5 Rs per kWh. It isthe average cost of production to be 3.50 Rs. per kWh, or $the cost of production significantly at 4.80 Rs. per kWh. As

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

219

Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners  

E-Print Network [OSTI]

chapter we discuss market, energy consumption and technologyeffective Room AC energy efficiency market transformation42 Chapter 3 Room AC Market and Energy Consumption

Shah, Nihar

2014-01-01T23:59:59.000Z

220

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

E-Print Network [OSTI]

017F.PDF KEMA, Inc. 2011. PJM Empirical Analysis of DemandMethods. Prepared for the PJM Markets Implementation~/media/markets-ops/dsr/pjm-analysis-of-dr-baseline-methods-

Bode, Josh

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Analysis of Efficiency Standards for Air Conditioners, Heat Pumps, and Other Products  

Reports and Publications (EIA)

A series of analyses showing the impacts of each of the selected provisions of the bills on energy supply, demand, and prices, macroeconomic variables where feasible, import dependence, and emissions.

2002-01-01T23:59:59.000Z

222

Engineering computer models for refrigerators, freezers, furnaces, water heaters, room and central air conditioners  

SciTech Connect (OSTI)

This User's Guide provides the necessary information for understanding and using a computer model developed for the US Department of Energy which predicts the performance (energy consumption) of household refrigerators, refrigerator-freezers, and freezers. The model is capable of simulating various cabinet configurations (top-mount, bottom-mount, side-by-side, single-door) and refrigeration unit combinations (back-mounted static condenser with single forced convection evaporator, hot wall condenser with cooled wall panels, etc.). The program is comprised of two main subroutines: a cabinet heat-load submodel and a refrigeration unit submodel; they can be used separately for preliminary design analysis or together for performance evaluations. A technical description of the model and information on how to structure input parameters are provided. The user is provided with specific guidance for running the model on a computer. Specific instructions are given in the Appendices for changing and running the model using the operating language compatible with the DOE computer terminal system. Other users will have to modify the procedures in these sections as necessary for different computers.

Not Available

1982-11-01T23:59:59.000Z

223

Advanced Thin Film Thermoelectric Systems forEfficient Air-Conditioner...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

& Publications Sheetak will work on developing a full scale prototype of its low cost heat pump water heater. These solid state heat pumping elements can be implemented in low...

224

An Analysis of Efficiency Improvements in Residential Sized Heat Pumps and Central Air Conditioners  

E-Print Network [OSTI]

LABORATORY NBS NATIONAL BUREAU OF STANDARDS NECPA NATIONAL ENERGY CONSERVATION POLICY ACT OEM ORIGINAL EQUIPMENT MANUFACTURERS ORNL OAK RIDGE NATIONAL LABORATORY PLF PART LOAD FACTOR SAI SCIENCE APPLICATION INCORPORATED SEER SEASONAL ENERGY EFFICIENCY RATIO... of variable speed units is discussed. The methodology includes: (1) making multiple runs of the Oak Ridge National Laboratory (ORNL) steady-state heat pump model, (2) making reasonable assumptions on the degradation factors, and (3) using a draft version...

O'Neal, D. L.; Boecker, C. L.; Penson, S. B.

1986-01-01T23:59:59.000Z

225

E-Print Network 3.0 - air conditioners Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Majid - School of Engineering Science, Simon Fraser University Collection: Engineering ; Energy Storage, Conversion and Utilization 2 T H E U N I V E R S I T Y O F C H I C A G O C...

226

E-Print Network 3.0 - air conditioner units Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Majid - School of Engineering Science, Simon Fraser University Collection: Engineering ; Energy Storage, Conversion and Utilization 2 T H E U N I V E R S I T Y O F C H I C A G O C...

227

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

decrease in energy consumption per unit GDP in the "Eleventh40-50% reduction in energy consumption per unit GDP by 2020measured by energy consumption per unit GDP in the “The 11th

Zhou, Nan

2010-01-01T23:59:59.000Z

228

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

E-Print Network [OSTI]

measurements using smart meter household data produce theof program households. Smart meters lower the cost of usingsample sizes with smart meter data can be far larger than

Bode, Josh

2013-01-01T23:59:59.000Z

229

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

further passed the Energy Efficiency (Labeling of Products)must be marked with an energy efficiency label informingconsumers of the energy efficiency level of related

Zhou, Nan

2010-01-01T23:59:59.000Z

230

Five ENERGY STAR Room Air Conditioners Fail Testing | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecordFederal Registry CommentsOverview »FINDINGDepartmentFive ENERGY STAR

231

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomenthe HouseStudents2.2at MultipleorderNuclearThis fact sheetHeat Pump Models Shown

232

DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomentheATLANTA, GA - U.S. Department of Energy Secretary StevenDeploymentForms

233

Tips for Running an Air Conditioner Without Breaking the Bank | Department  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas ConchasPassiveSubmittedStatusButler Tina Butler Tina-Butler.jpg Tina L. P.nuclearTipsof

234

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Deliciouscritical_materials_workshop_presentations.pdf MoreProgram |DOEInfrastructure Working420.1B FACILITYHeat

235

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

was maybe tested with less refrigerant charge than in China.Differences in the refrigerant charges are not confirmed byvacuum treatment, charge 850g±5g R22 refrigerant for sample

Zhou, Nan

2010-01-01T23:59:59.000Z

236

Measuring Short-term Air Conditioner Demand Reductions for Operations and Settlement  

E-Print Network [OSTI]

Ernest Orlando Lawrence Berkeley National Laboratory. LBNL-2008. Ernest Orlando Lawrence Berkeley National Laboratory.Ernest Orlando Lawrence Berkeley National Laboratory. LBNL-

Bode, Josh

2013-01-01T23:59:59.000Z

237

Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners  

E-Print Network [OSTI]

1986.Priceeffectsofenergy-efficient technologies—a study ofSAITO et al] EDR, “Technology Overview: Economizers”, Energyresources/publications/technology-overviews/technology-

Shah, Nihar

2014-01-01T23:59:59.000Z

238

Advanced Thin Film Thermoelectric Systems forEfficient Air-Conditioners |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartment of EnergyAdministrative2| DepartmentEnergy 2Waste Heat at GM

239

YMGI Through-the-Wall Air Conditioner Determined Noncompliant With Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergy Cooperation | Department ofEnergy IsTestimonials WorkerDepartmentHouse ofEnergy

240

Save Money and Stay Cool with an Efficient, Well-Maintained Air Conditioner  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists' Research |Regulation Services2014 UpdateTeach-Ins | Department of Energy|

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Evaluation of a Local Air Conditioning Duty Cycling Device as a Load Management Tool  

E-Print Network [OSTI]

the air conditioners were controlled. The local control device and the direct control device were both found to reduce demand of the compressor by about 0.65 kW at 100°F ambient temperature. Also, the kW reduction achieved was found to increase with higher...

Schneider, K.; Thedford, M.

1986-01-01T23:59:59.000Z

242

www.solas-int.org //00//00 surface ocean -lower atmosphere study Mid-Term Strategy theme: Air-sea gas fluxes at Eastern boundary Upwelling and Oxygen Minimum Zone (OMZ) systems  

E-Print Network [OSTI]

www.solas-int.org //00//00 surface ocean - lower atmosphere study Mid-Term Strategy theme: Air at the SOLAS workshop on "Air-sea fluxes at the Eastern Boundary Upwelling and OMZ systems" 8-10 November 2010

243

Table Contents Page i 2013 Nonresidential Compliance Manual January 2014  

E-Print Network [OSTI]

Table B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner ....................................................................................11 Table B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps...........12 Central Air Conditioner Test Methods

244

Creating and Implementing a Regularized Monitoring and Enforcement System for China's Mandatory Standards and Energy Information Label for Appliances  

E-Print Network [OSTI]

for 11 products including: refrigerators; air conditioners;on room air-conditioners, which covered products from 29for 11 products including: refrigerators; air conditioners;

Lin, Jiang

2008-01-01T23:59:59.000Z

245

Compliance and Verification of Standards and Labeling Programs in China: Lessons Learned  

E-Print Network [OSTI]

covering two products (refrigerators and air conditioners),and unitary air conditioners) and 15 other products areprogram by products and location room air conditioners Fix

Saheb, Yamina

2011-01-01T23:59:59.000Z

246

Status of China's Energy Efficiency Standards and Labels for Appliances and International Collaboration  

E-Print Network [OSTI]

is applied to four products including: air conditioners;to cover four products including: air conditioners; house-size - for three products (refrigerators, air-conditioners

Zhou, Nan

2010-01-01T23:59:59.000Z

247

Status of the Local Enforcement of Energy Efficiency Standards and Labeling Program in China  

E-Print Network [OSTI]

Check-Testing Sample Product Room air conditioners Self-in part, for five products: room air conditioners, electricCompliance Results Products Inspected Room air conditioners

Zhou, Nan

2013-01-01T23:59:59.000Z

248

Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms  

E-Print Network [OSTI]

a prototype improved heat pump air conditioner was developedwith standard 10 SEER heat pump air conditioner equipment.generated by the wall mount heat pump air conditioner (HPAC)

Apte, Michael; Michael G. Apte, Bourassa Norman, David Faulkner, Alfred T. Hodgson,; Toshfumi Hotchi, Michael Spears, Douglas P. Sullivan, and Duo Wang

2008-01-01T23:59:59.000Z

249

Cash for Coolers  

E-Print Network [OSTI]

for refrigerator and air conditioner replacement and allof refrigerator and air-conditioner replacement on householdthat replacement of residential air conditioners would save

Davis, Lucas W.; Fuchs, Alan; Gertler, Paul J.

2012-01-01T23:59:59.000Z

250

Impact of Large Scale Energy Efficiency Programs On Consumer Tariffs and Utility Finances in India  

E-Print Network [OSTI]

like refrigerator and air conditioner replacements. Thisiv) Replacement of conventional air conditioners by energy-ii) Replacement of conventional air conditioners by energy-

Abhyankar, Nikit

2011-01-01T23:59:59.000Z

251

Cash for Coolers  

E-Print Network [OSTI]

of refrigerator and air-conditioner replacement on householdfor refrigerator and air conditioner replacement and allassociated with air-conditioner replacement were to be

Davis, Lucas W.; Fuchs, Alan; Gertler, Paul J.

2012-01-01T23:59:59.000Z

252

Impact of Large Scale Energy Efficiency Programs On Consumer Tariffs and Utility Finances in India  

E-Print Network [OSTI]

like refrigerator and air conditioner replacements. This5-star air conditioners are the efficient replacement, withiv) Replacement of conventional air conditioners by energy-

Abhyankar, Nikit

2011-01-01T23:59:59.000Z

253

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in China  

E-Print Network [OSTI]

television and an air conditioner. In the future, ownershipresidential room air conditioners require the largesttelevision and an air conditioner. In the future, ownership

McNeil, Michael A.

2012-01-01T23:59:59.000Z

254

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network [OSTI]

9   1.2.1.   Air Conditioner Testing and 16   2.0   Air Conditioner Results of Residential Air Conditioner Testing in WECC,” 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

255

Current Status and Future Scenarios of Residential Building Energy Consumption in China  

E-Print Network [OSTI]

in MJ /household-year. Air conditioner and refrigerator endand 217.4% for air conditioner in Japan in 2000 (IEEJ,appliances including air conditioner, refrigerator, clothes

Zhou, Nan

2010-01-01T23:59:59.000Z

256

Modeling diffusion of electrical appliances in the residential sector  

E-Print Network [OSTI]

Error Distribution - Air Conditioners Error Distribution -televisions, and air conditioners 5 . The task of modelingfrom UNDESA. 2.1.3. Air Conditioner Climate Variable

McNeil, Michael A.

2010-01-01T23:59:59.000Z

257

RESIDENTIAL THERMOSTATS: COMFORT CONTROLS IN CALIFORNIA HOMES  

E-Print Network [OSTI]

Measures on Residential Air Conditioner Loads. Proc. ACEEEDeterminants of Central Air Conditioner Duty Cycles. Proc.at the number of air conditioners that might actually

Meier, Alan K.

2008-01-01T23:59:59.000Z

258

TWOZONE USERS MANUAL. 2d ed  

E-Print Network [OSTI]

cooler, improved air conditioner algorithm, ability to readcooling the house with air-conditioner, evaporative-cooler= starting month of air-conditioner (AC) operation. = ending

Gadgil, A.J.

2008-01-01T23:59:59.000Z

259

Customer Impact Evaluation for the 2009 Southern California Edison Participating Load Pilot  

E-Print Network [OSTI]

duration interruptions of air-conditioners. Still, we should14 3.2.2 Typical Summer Air Conditioner15 Table 3.3 Air Conditioner

Gifford, William

2010-01-01T23:59:59.000Z

260

Check-Testing of Manufacturer Self Reported Labeling Data & Compliance with MEPS  

E-Print Network [OSTI]

2 Room Air-conditioner Air-conditioner Initial test- ing Re-HFS BJS BJS HFS BJS BJS Non- compliant* Air-conditioner9 Table 5. Room Air Conditioner 2000

Zhou, Nan

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network [OSTI]

2009.   Inverter  Test Procedures Solar Generation Impact Conditioner Testing Procedures  Appendix B: Air Conditioner air conditioner testing procedures and results from studies 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

262

Method and apparatus for analog signal conditioner for high speed, digital x-ray spectrometer  

DOE Patents [OSTI]

A signal processing system which accepts input from an x-ray detector-preamplifier and produces a signal of reduced dynamic range for subsequent analog-to-digital conversion. The system conditions the input signal to reduce the number of bits required in the analog-to-digital converter by removing that part of the input signal which varies only slowly in time and retaining the amplitude of the pulses which carry information about the x-rays absorbed by the detector. The parameters controlling the signal conditioner's operation can be readily supplied in digital form, allowing it to be integrated into a feedback loop as part of a larger digital x-ray spectroscopy system.

Warburton, William K. (1300 Mills St., Menlo Park, CA 94025); Hubbard, Bradley (Santa Cruz, CA)

1999-01-01T23:59:59.000Z

263

Tariff-based analysis of commercial building electricity prices  

E-Print Network [OSTI]

Central Air Conditioners and Heat Pump Energy ConservationUnitary Air Conditioners and Heat Pumps ANOPR Technical

Coughlin, Katie M.; Bolduc, Chris A.; Rosenquist, Greg J.; Van Buskirk, Robert D.; McMahon, James E.

2008-01-01T23:59:59.000Z

264

Current Status and Future Scenarios of Residential Building Energy Consumption in China  

E-Print Network [OSTI]

stove district heating heat pump air conditioner Table 2Heat Pump Percentage (%) Heat Pump Air Conditioner District

Zhou, Nan

2010-01-01T23:59:59.000Z

265

Minimum Gas Service Standards (Ohio)  

Broader source: Energy.gov [DOE]

Natural gas companies in Ohio are required to follow the Minimum Gas Service Standards, which are set and enforced by the Public Utilities Commission of Ohio. These rules are found in chapter 4901...

266

Minimum Stream Flow Standards (Connecticut)  

Broader source: Energy.gov [DOE]

These regulations apply to all dams and structures which impound or divert waters on rivers or their tributaries, with some exceptions. The regulations set standards for minimum flow (listed in the...

267

Central Air Conditioners","Heat Pumps","Individual Air Conditioners","District Chilled Water","Central Chillers","Packaged  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia,(Million Barrels) Crude Oil Reserves in Nonproducing Reservoirs (MillionExpected FutureYearFeet)Feet)Process:4.

268

Central Air Conditioners","Heat Pumps","Individual Air Conditioners","District Chilled Water","Central Chillers","Packaged  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia,(Million Barrels) Crude Oil Reserves in Nonproducing Reservoirs (MillionExpected

269

Air-Source Heat Pumps | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomen Owned SmallOfCoal_Budget_Fact_Sheet.pdfAir conditioners cost U.S.When properly

270

Desiccant Enhanced Evaporative Air-Conditioning (DEVap): Evaluation of a New Concept in Ultra Efficient Air Conditioning  

SciTech Connect (OSTI)

NREL has developed the novel concept of a desiccant enhanced evaporative air conditioner (DEVap) with the objective of combining the benefits of liquid desiccant and evaporative cooling technologies into an innovative 'cooling core.' Liquid desiccant technologies have extraordinary dehumidification potential, but require an efficient cooling sink. DEVap's thermodynamic potential overcomes many shortcomings of standard refrigeration-based direct expansion cooling. DEVap decouples cooling and dehumidification performance, which results in independent temperature and humidity control. The energy input is largely switched away from electricity to low-grade thermal energy that can be sourced from fuels such as natural gas, waste heat, solar, or biofuels.

Kozubal, E.; Woods, J.; Burch, J.; Boranian, A.; Merrigan, T.

2011-01-01T23:59:59.000Z

271

MINIMUM COMPLEXITY UNINHABITED AIR VEHICLE GUIDANCE AND FLIGHT CONTROL SYSTEM  

E-Print Network [OSTI]

. An architecture is proposed, which utilizes observers for bank angle and wind components to reconstruct (GPS receiver), and in boxes on the sides of the fuselage (computer and battery) This model aircraft

Johnson, Eric N.

272

Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges  

SciTech Connect (OSTI)

Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40percent cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

Phadke, Amol; Abhyankar, Nikit; Shah, Nihar

2014-06-19T23:59:59.000Z

273

Assessing the Impact of Measurement Policy on the Accuracy of Certified Energy Efficiency Ratio for Split-System Air Conditioners  

E-Print Network [OSTI]

Efficiency and Renewable Energy, Building Technologiesand Renewable Energy, Office of Building Technology, State,

Yu, Bingyi

2013-01-01T23:59:59.000Z

274

Development of Temperature and Humidity-Based Indicators for Diagnosing Problems in Low Tonnage, Split System Air Conditioners  

E-Print Network [OSTI]

of HVAC systems for building optimization, fault detection and diagnosis. October. Finland: Technical Research Center of Finland, Laboratory of Heating and Ventilation, B. 0. Box 206 (Lampomiehenkuja 3) 02150 ESPOO. Kaler. G. 1988. Expert system...

Watt, J. B.; O'Neal, D. L.; Haberl, J. S.

1998-01-01T23:59:59.000Z

275

Avoiding 100 new power plants by increasing efficiency of room air conditioners in India: opportunities and challenges  

SciTech Connect (OSTI)

Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40% cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

Phadke, Amol; Abhyankar, Nikit; Shah, Nihar; [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

2013-10-15T23:59:59.000Z

276

PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976  

E-Print Network [OSTI]

solar collectors almost certainly reqld res evaporat 1ve coo 1 i ng towers,tower for water- cooling the condenser was an overriding concern in development of a practical solar

Dao, K.

2010-01-01T23:59:59.000Z

277

NREL Demonstrates Game-Changing Air Conditioner Technology (Fact Sheet), Highlights in Research & Development, NREL (National Renewable Energy Laboratory)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas Conchas recoveryLaboratory | National Nuclearover two yearsNP UserReportTesting of DEVAP

278

NREL Solves Residential Window Air Conditioner Performance Limitations (Fact Sheet), Highlights in Research & Development, NREL (National Renewable Energy Laboratory)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas Conchas recoveryLaboratory | National Nuclearover two yearsNPResults giveSimulator fOr Wind13

279

An Evaluation of the Effects of Refrigerant Charge on a Residential Central Air Conditioner with Orifice Expansion  

E-Print Network [OSTI]

had one row of tubes with spine fins spaced at 20 per inch. The face area of the coil was 20.94 ft with refrigerant tube sizes of 3/8". The outdoor fan was located on the top of the outdoor coil. The fan specifications are given in Table 2.... 2.5 Table 2.1 - Fan Specification Refrigerant Side A schematic of the refrigerant circuit is shown in Figure 2.3. Refrigerant pressures were monitored at the 6 points shown with the use of 0-300 psig pressure transducers. To accurately measure...

O'Neal, D. L.; Ramsey, C. J.; Farzad, M.

1989-01-01T23:59:59.000Z

280

PERFORMANCE OF AN EXPERIMENTAL SOLAR-DRIVEN ABSORPTION AIR CONDITIONER--ANNUAL REPORT JULY 1975-SEPT. 1976  

E-Print Network [OSTI]

U. THW . In T HW out TSS Q UW (Btu/hr) LiT m U IllWS (Ibs/OF) (OF) (OF) (OF) (OF) (Btu/hr ft2.F 20A 20C 19A lIS 17BU Run number m HW (1bs/hr) (Btu/hr- ft2_F) mS == ! z(nlWS+

Dao, K.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Air Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Why Air Quality Air Quality To preserve our existing wilderness-area air quality, LANL implements a conscientious program of air monitoring. April 12, 2012 Real-time data...

282

Study of solar-assisted thermoelectric technology for automobile air conditioning  

SciTech Connect (OSTI)

An analytical study was conducted to determine the feasibility of employing solar energy assisted thermoelectric (TE) cooling technology in automobile air conditioners. The study addressed two key issues -- power requirements and availability of thermoelectric materials. In this paper a mathematical model was developed to predict the performance of TE air conditioners and to analyze power consumption. Results show that the power required to deliver a cooling capacity of 4 kW (13,680 Btu/h) in a 38 C (100 F) environment will be 9.5 kW electric. Current TE modules suitable for air conditioning are made of bismuth telluride. The element tellurium is expected to be in short supply if TE cooling is widely implemented for auto air conditioning; some options available in this regard were studied and presented in this paper. The photovoltaic (PV) cells, assumed to cover the roof area of a compact car can only generate about 225 W. However, this is more than enough to power a fan to provide air ventilation to the car interior which significantly reduces the peak cooling load when the car is parked in bright sunlight.

Mei, V.C.; Chen, F.C. [Oak Ridge National Lab., Oak Ridge, TN (United States); Mathiprakasam, B.; Heenan, P. [Midwest Research Inst., Kansas City, MO (United States)

1993-11-01T23:59:59.000Z

283

Calendar Year 2007 Program Benefits for U.S. EPA Energy Star Labeled Products: Expanded Methodology  

E-Print Network [OSTI]

Air Conditioners and Air Source Heat Pumps. Unpublishedpackage central air conditioners and heat pumps, rated atManufacturers air source heat pump American Society of

Sanchez, Marla

2010-01-01T23:59:59.000Z

284

Magnetic Refrigeration Technology for High Efficiency Air Conditioning  

SciTech Connect (OSTI)

Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate heat exchangers or oil distribution issues found in traditional vapor compression systems.

Boeder, A; Zimm, C

2006-09-30T23:59:59.000Z

285

Category Measure Minimum Efficiency / Certification  

E-Print Network [OSTI]

and cooling (floor, wall, and ceiling) Radiant systems must be powered by a heat pump (electric or gas-fired, or ground-source), efficient gas boiler, or solar system (not by electric resistance) $4000-$20000 none sealing $300-$1200 Not clear if Xcel insulation/air sealing rebate applies here Energy or heat recovery

Kammen, Daniel M.

286

On Cartesian trees and range minimum queries  

E-Print Network [OSTI]

We present new results on Cartesian trees with applications in range minimum queries and bottleneck edge queries. We introduce a cache-oblivious Cartesian tree for solving the range minimum query problem, a Cartesian tree ...

Demaine, Erik D.

287

HEAT Loan Minimum Standards and Requirements  

Broader source: Energy.gov [DOE]

Presents additional resources on loan standards and requirements from Elise Avers' presentation on HEAT Loan Minimum Standards and Requirements.

288

PESC'99, Charleston, South Carolina, June 27 July 1, pp. 393-399. A Multilevel Converter-Based Universal Power Conditioner  

E-Print Network [OSTI]

, and reactive power compensation. Level usage in the series inverter and parallel inverter is analyzed that the customer can impose on the utility. To meet the objectives detailed in these new premium power agreements- clamped inverter into a universal power conditioner is an enticing prospect. A multilevel universal power

Tolbert, Leon M.

289

Energy Consumption of Minimum Energy Coding in  

E-Print Network [OSTI]

Energy Consumption of Minimum Energy Coding in CDMA Wireless Sensor Networks Benigno Zurita Ares://www.ee.kth.se/control Abstract. A theoretical framework is proposed for accurate perfor- mance analysis of minimum energy coding energy consumption is analyzed for two coding schemes proposed in the literature: Minimum Energy coding

Johansson, Karl Henrik

290

Multiple criteria minimum spanning trees Pedro Cardoso  

E-Print Network [OSTI]

Multiple criteria minimum spanning trees Pedro Cardoso M´ario Jesus ´Alberto M´arquez Abstract The NP multiple criteria minimum spanning tree as several applications into the network design problems criteria minimum spanning trees. There are several geometric network design and application problems

Coello, Carlos A. Coello

291

Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1  

E-Print Network [OSTI]

A H A M . 1991. Room Air Conditioner Data. Association of7. FUTURE WORK 7.1 Room Air Conditioners 7.2. Common heatingShipments of Unitary Air Conditioners and Heat Pumps. Air-

Johnson, F.X.

2010-01-01T23:59:59.000Z

292

Energy Consumption, Efficiency, Conservation, and Greenhouse Gas Mitigation in Japan's Building Sector  

E-Print Network [OSTI]

4.4.3 C o o l i n g Air Conditioner Multi-room Load AirGHPs) Chillers Air Conditioner COP Desiccant Conditioningappliances such as air-conditioners, refrigerators and

2006-01-01T23:59:59.000Z

293

E-Print Network 3.0 - air velocity temperature Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and Medicine ; Environmental Sciences and Ecology 66 Water Modeling of Steel Flow, Air Entrainment and Filtration Summary: . In general, a certain minimum velocity has to be...

294

Energy Blog | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

single room air conditioners, water heathers, central air conditioners, air-source heat pumps, furnaces and ground-source heat pumps. August 27, 2010 New LED lighting...

295

Realized and Projected Impacts of U.S. Energy Efficiency Standards for Residential and Commercial Appliances  

E-Print Network [OSTI]

Standards for Consumer Products: Room Air Conditioners,Energy Savings -- Residential Products Room Air Conditionersfor Consumer Products: Residential Central Air Conditioners

Meyers, Stephen P.

2008-01-01T23:59:59.000Z

296

Assessment of the Impacts of Standards and Labeling Programs in Mexico (four products).  

E-Print Network [OSTI]

Level Trends – Air Conditioner Product Classes Product Class7 – Efficiency of Air Conditioner Product Classes (Watts/for four major products: household refrigerators, room air

Sanchez, Itha; Pulido, Henry; McNeil, Michael A.; Turiel, Isaac; della Cava, Mirka

2007-01-01T23:59:59.000Z

297

Compliance and Verification of Standards and Labelling Programs in China: Lessons Learned  

E-Print Network [OSTI]

for household refrigerators/ freezers and room airZhou et al 2008] Refrigerators Freezers Air conditionersZhou et al 2008] Refrigerators Freezers Air conditioners

Saheb, Yamina

2010-01-01T23:59:59.000Z

298

Compliance and Verification of Standards and Labeling Programs in China: Lessons Learned  

E-Print Network [OSTI]

for household refrigerators/ freezers and room airZhou et al 2008] Refrigerators Freezers Air conditionersZhou et al 2008] Refrigerators Freezers Air conditioners

Saheb, Yamina

2011-01-01T23:59:59.000Z

299

Calendar Year 2009 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network [OSTI]

covers central air conditioners and heat pumps with up toconditioning, ASHP = air source heat pump, HP = heat pump,Conditioners and Air-Source Heat Pumps • Commercial Fryers •

Homan, Gregory K

2011-01-01T23:59:59.000Z

300

Calendar Year 2008 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network [OSTI]

covers central air conditioners and heat pumps with up toconditioning, ASHP = air source heat pump, HP = heat pump,Conditioners and Air-Source Heat Pumps • Commercial Fryers •

Homan, GregoryK

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Hazardous Waste Minimum Distance Requirements (Connecticut)  

Broader source: Energy.gov [DOE]

These regulations set minimum distance requirements between certain types of facilities that generate, process, store, and dispose of hazardous waste and other land uses. The regulations require an...

302

Knots and Minimum Distance Energy Rosanna Speller  

E-Print Network [OSTI]

Knots and Minimum Distance Energy Rosanna Speller (Dated: May 11, 2008) Professor Elizabeth Denne have least Minimum Distance Energy. I previously showed that the energy is minimized for convex polygons. We hope relating the energy to chords of polygons will be a helpful step towards showing

Denne, Elizabeth

303

Residence Hall & Furnished  

E-Print Network [OSTI]

Air Conditioner Units . . . . . . . . . . . . . . . . . 7 Bunking/Lofting Beds & Air Conditioning . . . . . . . . . . . . 9 Mailing Address

Polly, David

304

TABLE OFCONTENTS Contract Information  

E-Print Network [OSTI]

....................................... 3 Your Room Assignments .......................................................... 4 Air Conditioner ................................................... 4 Consolidation ......................................................... 4 Heating &Air

Polly, David

305

Market and behavioral barriers to energy efficiency: A preliminary evaluation of the case for tariff financing in California  

E-Print Network [OSTI]

for central air conditioner replacements Efficiency level 20state, replacement of outdated central air conditioners orAir Conditioners .. 15   Furnaces 16   Water heaters .. 17   Potential savings from rental housing unit water heater replacements .

Fujita, K. Sydny

2012-01-01T23:59:59.000Z

306

CONTROL SYSTEM FOR SOLAR HEATING and COOLING  

E-Print Network [OSTI]

~O"')4 REFERENCES The air conditioner work is the subject ofAmmonia-Water Absorption Air Conditioner", by M. Simmons, R.water absorption air conditioner, (1) and the establishment

Dols, C.

2010-01-01T23:59:59.000Z

307

BPM Motors in Residential Gas Furnaces: What are the Savings?  

E-Print Network [OSTI]

Comfort Series 13 Air Conditioner with Puron Refrigerant.for new houses with 3.5 ton air-conditioners from a study ofblower use by the air conditioner and stand-by power.

Lutz, James; Franco, Victor; Lekov, Alex; Wong-Parodi, Gabrielle

2006-01-01T23:59:59.000Z

308

TWOZONE USERS MANUAL  

E-Print Network [OSTI]

9. Sizing chart for air conditioner. z ~::~~OOOOOOOOOOOOOOOOoperation of either an air conditioner and/or an evaporativecooler, improved air-conditioner algorithm, ability to read

Gadgil, Ashok J.

2010-01-01T23:59:59.000Z

309

TWOZONE USERS MANUAL  

E-Print Network [OSTI]

9. Sizing chart for air conditioner. z ~::~~OOOOOOOOOOOOOOOOoperation of either an air conditioner and/or an evaporativecooler, improved air-conditioner algorithm, ability to read

Gadgil, Ashok J.

2008-01-01T23:59:59.000Z

310

Global Potential of Energy Efficiency Standards and Labeling Programs  

E-Print Network [OSTI]

impact of room air conditioners energy labels in Malaysia."of electric Room Air Conditioner." Energy Economics 20Standard Levels for Room Air Conditioners. McNeil, M. A. ,

McNeil, Michael A

2008-01-01T23:59:59.000Z

311

Minimum rank of graphs that allow loops.  

E-Print Network [OSTI]

??The traditional "minimum rank problem" for simple graphs associates a set of symmetric matrices, the zero-nonzero pattern of whose off-diagonal entries are described by the… (more)

Mikkelson, Rana C.

2008-01-01T23:59:59.000Z

312

Credible Research Designs for Minimum Wage Studies  

E-Print Network [OSTI]

adjusted Current Employment Statistics data from BLS. TheBureau of Labor Statistics’ Employment and Earnings Reports.and Statistics 92, 4: 945-64. [27] _________2013. “Minimum Wage Shocks, Employment

Allegretto, Sylvia; Dube, Arindrajit; Reich, Michael; Zipperer, Ben

2013-01-01T23:59:59.000Z

313

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network [OSTI]

Air Conditioner Testing in WECC,” IEEE Power  Engineering Air Conditioner Modeling, WECC Load Modeling Task  Force in power system studies: WECC progress update,? Power and 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

314

Jengeih Tamba U.S. Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

report. The study states that between 2006 and the beginning of 2013, manufacturers of residential furnaces, air conditioners, heat pumps and commercial unitary air conditioners...

315

Impacts of Imported Liquefied Natural Gas on Residential Appliance Components: Literature Review  

E-Print Network [OSTI]

on New FVIR Water Heaters." Retrieved 04/17/2009, 2009, fromAir Conditioners, Water Heaters, Direct Heating Equipment,Air Conditioners, Water Heaters, Direct Heating Equipment,

Lekov, Alex

2010-01-01T23:59:59.000Z

316

Using National Survey Data to Estimate Lifetimes of Residential Appliances  

E-Print Network [OSTI]

furnaces, boilers, water heaters, room air-conditioners,furnaces, boilers, water heaters, room air-conditioners (and Electric Storage Water Heaters Table 6 and 7 show the

Lutz, James D.

2013-01-01T23:59:59.000Z

317

Page 1 of 3 Radiogram No. 1679u Form 24 for 03/02/2013  

E-Print Network [OSTI]

Subsystem Preventive Maintenance, Group E FGB 2 Fan Cleaning Inspection of Air Conditioner Inspection Inspection of Air Conditioner Inspection and Cleaning of Auxiliary Computer System () Laptops

318

ITP Steel: Theoretical Minimum Energies to Produce Steel for...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Theoretical Minimum Energies to Produce Steel for Selected Conditions, March 2000 ITP Steel: Theoretical Minimum Energies to Produce Steel for Selected Conditions, March 2000...

319

Cascade Reverse Osmosis Air Conditioning System: Cascade Reverse Osmosis and the Absorption Osmosis Cycle  

SciTech Connect (OSTI)

BEETIT Project: Battelle is developing a new air conditioning system that uses a cascade reverse osmosis (RO)-based absorption cycle. Analyses show that this new cycle can be as much as 60% more efficient than vapor compression, which is used in 90% of air conditioners. Traditional vapor-compression systems use polluting liquids for a cooling effect. Absorption cycles use benign refrigerants such as water, which is absorbed in a salt solution and pumped as liquid—replacing compression of vapor. The refrigerant is subsequently separated from absorbing salt using heat for re-use in the cooling cycle. Battelle is replacing thermal separation of refrigerant with a more efficient reverse osmosis process. Research has shown that the cycle is possible, but further investment will be needed to reduce the number of cascade reverse osmosis stages and therefore cost.

None

2010-09-01T23:59:59.000Z

320

Building Information Modeling - A Minimum Mathematical Configuration  

E-Print Network [OSTI]

minimum information required to execute the construction of a project. A plain concrete beam element was used as the case study for this research. The results show that a minimal information schema can be developed for a simple building element. Further...

Bhandare, Ruchika

2012-10-19T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Learning Minimum Volume Sets Clayton Scott  

E-Print Network [OSTI]

Learning Minimum Volume Sets Clayton Scott Statistics Department Rice University Houston, TX 77005 herein are primarily of theoretical interest, although they may be implemented e#eciently for certain measure based on S: # P (G) = (1/n) # n i=1 I(X i # G). Here I(·) is the indicator function. Set µ

Scott, Clayton

322

Minimum Energy Diagrams for Multieffect Distillation Arrangements  

E-Print Network [OSTI]

and the energy use from this process accounts for an estimated 3% of the world energy consumption.1 With rising on the overall plant energy consumption. The use of heat integration combined with complex config- urations distillation ar- rangements. An easy form of comparison for energy consumption is the minimum vapor flow rate

Skogestad, Sigurd

323

Parametric and Kinetic Minimum Spanning Trees Pankaj K. Agarwal 1  

E-Print Network [OSTI]

Parametric and Kinetic Minimum Spanning Trees Pankaj K. Agarwal 1 David Eppstein 2 Leonidas J. Guibas 3 Monika R. Henzinger 4 Abstract We consider the parametric minimum spanning tree problem- pute the sequence of minimum spanning trees generated as varies. We also consider the kinetic minimum

Eppstein, David

324

Synchronous Programs Testing Language Mouna TKA Mnad1  

E-Print Network [OSTI]

of the language Let's consider the following simple reactive program, an air-conditioner controller. The program inputs are: onOff (Boolean: true when the user pushes the On-Off button of the air-conditioner), Tamb of the air-conditioner ) and Tout (integer: indicates the temperature of the air that the air-conditioner

Boyer, Edmond

325

Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps  

E-Print Network [OSTI]

and energy usage characteristics for each of the 77 nationally representative buildings (determined from the computer modeling analysis) to actual modeled commercial

Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

2001-01-01T23:59:59.000Z

326

Air Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUCProductstwrmrAre theAdministratorCFM LEAPAgendaConditioning AirWhy » Air

327

Air Quality: Construction Project Air Permit Requirements  

E-Print Network [OSTI]

Air Quality: Construction Project Air Permit Requirements Department: Chemical and General Safety Program: Air Quality Owner: Program Manager Authority: ES&H Manual, Chapter 30, Air Quality1 All manager or operator must submit the completed form to the air quality program manager before the project

Wechsler, Risa H.

328

Minimum-fuel trajectories for a hypersonic passenger aircraft  

E-Print Network [OSTI]

-breathing turbojet - ramjet / scramjet inria-00582978,version1-4Apr2011 #12;Model: Atmosphere air temperature [K] air

Boyer, Edmond

329

Approximating the Minimum Spanning Tree Weight in Sublinear Time  

E-Print Network [OSTI]

Approximating the Minimum Spanning Tree Weight in Sublinear Time Bernard Chazelle #3; Ronitt a parameter 0 minimum spanning tree- components algorithm picks O(1=#15; 2 ) vertices in the graph and then grows \\local spanning trees" whose

Trevisan, Luca

330

A Generalized Battery Model of a Collection of Thermostatically Controlled Loads for Providing Ancillary Service  

E-Print Network [OSTI]

. Residential Thermostatically Controlled Loads (TCLs) such as air conditioner, heat pump, water heater, and re

Sanandaji, Borhan M.

331

Realized and Projected Impacts of U.S. Energy Efficiency Standards for Residential and Commercial Appliances  

E-Print Network [OSTI]

and Heat Pumps Room Air Conditioners Water Heaters Gas Furnaces Clothes Washers Clothes Dryers Dishwashers COMMERCIAL

Meyers, Stephen P.

2008-01-01T23:59:59.000Z

332

Performance Method Overview Page 7-1 7 Performance Method  

E-Print Network [OSTI]

charge in air conditioners · Heating and cooling equipment efficiency · High EER air conditioners storage air conditioners · Air conditioners with evaporatively-cooled condensers · Evaporative coolers ventilation · Zonal control · Water heater efficiency and distribution system type Credit for many

333

Essays on the household-level effects of house price growth  

E-Print Network [OSTI]

replacement of major equipment items such as water heaters, furnaces, and central air conditioners” (

Sitgraves, Claudia Ayanna

2009-01-01T23:59:59.000Z

334

California DREAMing: the design of residential demand responsive technology with people in mind  

E-Print Network [OSTI]

replacement (Vandervort, 2006). The proper changing of the refrigerant can also significantly improve air conditioner

Peffer, Therese E.

2009-01-01T23:59:59.000Z

335

Essays on the household-level effects of house price growth  

E-Print Network [OSTI]

and replacement of major equipment items such as water heaters, furnaces, and central air conditioners” (

Sitgraves, Claudia Ayanna

2009-01-01T23:59:59.000Z

336

Investigation of efficiency droop for InGaN-based UV light-emitting diodes with InAlGaN barrier  

E-Print Network [OSTI]

applications in photocatalytic deodorizing such as air conditioner,1 and there have been interests in solid

337

IMPACT OF FOREST CERTIFICATION: FROM THE PERSPECTIVE OF FOREST CONCESSIONAIRES' STAFFS  

E-Print Network [OSTI]

by acting as anti pollutants, natural air conditioner and balancing the ecosystem. However, deforestation

338

ARRA Proposed Award: The Affordable Multifamily Retrofit Initiative (the Initiative)  

E-Print Network [OSTI]

Star appliance replacement; air conditioner and/or furnace replacement or installation defect repair; cool roofs

339

Applied Intelligence 13, 259264, 2000 c 2000 Kluwer Academic Publishers. Manufactured in The Netherlands.  

E-Print Network [OSTI]

Problem Consider the following rules for controlling an air conditioner: (1) Run the air conditioner when the temperature is over 78 . (2) Do not run the air conditioner when the AC line voltage is low, unless) Never run the air conditioner if it was turned off less than 4 minutes ago (to protect the compressor

Covington, Michael A.

340

ARRA Proposed Award: Home Performance Program  

E-Print Network [OSTI]

Star appliance replacement; air conditioner and/or furnace replacement or installation defect repair; cool roofs

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Volume 9 Number 3 Fall 2000 University to invest  

E-Print Network [OSTI]

manager of Purdue's mechanical and electrical structures, had all the window air conditioner units removed

342

TENANT NAME ADDRESS APT#  

E-Print Network [OSTI]

cabinets Bath exhaust fan Medicine cabinet Air conditioner Washer/dryer Other # KEYS: RECEIVED RETURNED

Kravets, Robin

343

Additions, Alterations, and Repairs Introduction Page 8-1 8 Additions, Alterations, and Repairs  

E-Print Network [OSTI]

conditioning and heating system. 5. Replacing an air conditioner or the exterior unit or indoor coil of a split system air conditioner. 6. Replacing of a furnace or water heater. 7. Replacing windows where all compressor in an air conditioner but not replacing the entire air conditioner. 3. Replacing a failed fan

344

Minimum cost model energy code envelope requirements  

SciTech Connect (OSTI)

This paper describes the analysis underlying development of the U.S. Department of Energy`s proposed revisions of the Council of American Building Officials (CABO) 1993 Model Energy Code (MEC) building thermal envelope requirements for single-family and low-rise multifamily residences. This analysis resulted in revised MEC envelope conservation levels based on an objective methodology that determined the minimum-cost combination of energy efficiency measures (EEMs) for residences in different locations around the United States. The proposed MEC revision resulted from a cost-benefit analysis from the consumer`s perspective. In this analysis, the costs of the EEMs were balanced against the benefit of energy savings. Detailed construction, financial, economic, and fuel cost data were compiled, described in a technical support document, and incorporated in the analysis. A cost minimization analysis was used to compare the present value of the total long-nm costs for several alternative EEMs and to select the EEMs that achieved the lowest cost for each location studied. This cost minimization was performed for 881 cities in the United States, and the results were put into the format used by the MEC. This paper describes the methodology for determining minimum-cost energy efficiency measures for ceilings, walls, windows, and floors and presents the results in the form of proposed revisions to the MEC. The proposed MEC revisions would, on average, increase the stringency of the MEC by about 10%.

Connor, C.C.; Lucas, R.G.; Turchen, S.J.

1994-08-01T23:59:59.000Z

345

Minimum-Energy Multicast Tree in Cognitive Radio Networks  

E-Print Network [OSTI]

Minimum-Energy Multicast Tree in Cognitive Radio Networks Wei Ren, Xiangyang Xiao, Qing Zhao algorithm with bounded performance guarantee for constructing the minimum-energy multicast tree, which by studying the impact of the traffic load of the primary network on the minimum-energy multicast tree. I

Islam, M. Saif

346

Using Sparsification for Parametric Minimum Spanning Tree Problems  

E-Print Network [OSTI]

Using Sparsification for Parametric Minimum Spanning Tree Problems David Fern'andez­Baca 1? , Giora with a parameter. The second is an asymptotically optimal algorithm for the minimum ratio spanning tree problem, as well as other search problems, on dense graphs. 1 Introduction In the parametric minimum spanning tree

Eppstein, David

347

Using Sparsification for Parametric Minimum Spanning Tree Problems  

E-Print Network [OSTI]

Using Sparsification for Parametric Minimum Spanning Tree Problems David Fern´andez-Baca Giora algorithm for the minimum ratio spanning tree problem, as well as other search prob- lems, on dense graphs. 1 Introduction In the parametric minimum spanning tree problem, one is given an n-node, m

Eppstein, David

348

Stochastic Minimum Spanning Trees in Euclidean Spaces Pegah Kamousi #  

E-Print Network [OSTI]

Stochastic Minimum Spanning Trees in Euclidean Spaces Pegah Kamousi # Computer Science University­1­4503­0682­9/11/06 ...$10.00. Keywords Algorithms, Theory General Terms Stochastic Minimum Spanning Trees, Geometric Data and arbitrary but known probability p i . We want to compute the expected length of the minimum spanning tree

Chan, Timothy M.

349

On Two-Stage Stochastic Minimum Spanning Kedar Dhamdhere1  

E-Print Network [OSTI]

On Two-Stage Stochastic Minimum Spanning Trees Kedar Dhamdhere1 , R. Ravi2 , and Mohit Singh2 1}@andrew.cmu.edu Abstract. We consider the undirected minimum spanning tree problem in a stochastic optimization setting algorithm. We then consider the Stochastic minimum spanning tree problem in a more general black-box model

Ravi, R.

350

U< I 7 jjORNLCON-3S) EXPERIMENTAL ANALYSIS OF A WINDOW  

E-Print Network [OSTI]

UAIR CONDITIONER OAK RIDGE WITH NATIONAL R-22. #12;ORNUCON-389 EXPERIMENTAL ANALYSIS OF A WINDOW AIR CONDITIONER WITH R-22 AND ZEOTROPIC MIXTURE OF R

Oak Ridge National Laboratory

351

Metal-Air Batteries  

SciTech Connect (OSTI)

Metal-air batteries have much higher specific energies than most currently available primary and rechargeable batteries. Recent advances in electrode materials and electrolytes, as well as new designs on metal-air batteries, have attracted intensive effort in recent years, especially in the development of lithium-air batteries. The general principle in metal-air batteries will be reviewed in this chapter. The materials, preparation methods, and performances of metal-air batteries will be discussed. Two main metal-air batteries, Zn-air and Li-air batteries will be discussed in detail. Other type of metal-air batteries will also be described.

Zhang, Jiguang; Bruce, Peter G.; Zhang, Gregory

2011-08-01T23:59:59.000Z

352

Feasibility of an appliance energy testing and labeling program for Sri Lanka  

SciTech Connect (OSTI)

A feasibility study evaluated the costs and benefits of establishing a program for testing, labeling and setting minimum efficiency standards for appliances and lighting in Sri Lanka. The feasibility study included: refrigerators, air-conditioners, flourescent lighting (ballasts & CFls), ceiling fans, motors, and televisions.

Biermayer, Peter; Busch, John; Hakim, Sajid; Turiel, Issac; du Pont, Peter; Stone, Chris

2000-04-01T23:59:59.000Z

353

(ENFORCEMENT AGENCY CAN CUSTOMIZE WITH LETTERHEAD/SEAL)  

E-Print Network [OSTI]

). 2. Central air conditioners & heat pumps less than 65,000 Btu/hr must have a minimum 13 SEER. 3 permits include, but are not limited to: · New HVAC installation · HVAC Changeout · Replacement of furnace, coil, FAU, or condenser · Relocation of an existing HVAC unit · Adding or replacing more than 40ft

354

(ENFORCEMENT AGENCY CAN CUSTOMIZE WITH LETTERHEAD/SEAL)  

E-Print Network [OSTI]

have a minimum 78% AFUE (Exception: Wall & floor furnaces; room heaters). 2. Central air conditioners, but are not limited to: · New HVAC installation · HVAC Changeout · Replacement of furnace, coil, FAU, or condenser · Relocation of an existing HVAC unit · Adding or replacing more than 40ft ducting in unconditioned space 2008

355

Flammability limits of dusts: Minimum inerting concentrations  

SciTech Connect (OSTI)

A new flammability limit parameter has been defined as the Minimum Inerting Concentration (MIC). This is the concentration of inertant required to prevent a dust explosion regardless of fuel concentration. Previous experimental work at Fike in a 1-m{sup 3} spherical chamber has shown this flammability limit to exist for pulverized coal dust and cornstarch. In the current work, inerting experiments with aluminum, anthraquinone and polyethylene dusts as fuels were performed, using monoammonium phosphate and sodium bicarbonate as inertants. The results show that an MIC exists only for anthraquinone inerted with sodium bicarbonate. The other combustible dust and inertant mixtures did not show a definitive MIC, although they did show a strong dependence between inerting level and suspended fuel concentration. As the fuel concentration increased, the amount of inertant required to prevent an explosion decreased. Even though a definitive MIC was not found for most of the dusts an effective MIC can be estimated from the data. The use of MIC data can aid in the design of explosion suppression schemes.

Dastidar, A.G.; Amyotte, P.R. [Dalhousie Univ., Halifax, Nova Scotia (Canada). Dept. of Chemical Engineering] [Dalhousie Univ., Halifax, Nova Scotia (Canada). Dept. of Chemical Engineering; Going, J.; Chatrathi, K. [Fike Corp., Blue Springs, MO (United States)] [Fike Corp., Blue Springs, MO (United States)

1999-05-01T23:59:59.000Z

356

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 2, Fluorescent lamp ballasts, television sets, room air conditioners, and kitchen ranges and ovens  

SciTech Connect (OSTI)

This document is divided into ``volumes`` B through E, dealing with individual classes of consumer products. Chapters in each present engineering analysis, base case forecasts, projected national impacts of standards, life-cycle costs and payback periods, impacts on manufacturers, impacts of standards on electric utilities, and environmental effects. Supporting appendices are included.

Not Available

1993-11-01T23:59:59.000Z

357

Air temperature thresholds for indoor comfort and perceived air quality  

E-Print Network [OSTI]

in the Netherlands, Indoor Air 2, 127 – 136. BuildingPaliaga, G. (2009) Moving air for comfort. ASHRAE Journal,ventilation system on perceived air quality, Indoor Air

Zhang, Hui; Edward, Arens; Pasut, Wilmer

2012-01-01T23:59:59.000Z

358

Minimum concave cost flows in capacitated grid networks  

E-Print Network [OSTI]

We study the minimum concave cost flow problem over a two-dimensional .... as a building block for the theory of production planning and inventory control.

2014-03-31T23:59:59.000Z

359

Tungsten Cluster Migration on Nanoparticles: Minimum Energy Pathway...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Pathway and Migration Mechanism. Tungsten Cluster Migration on Nanoparticles: Minimum Energy Pathway and Migration Mechanism. Abstract: Transition state searches have been...

360

Optimization Online - Guaranteed Minimum-Rank Solutions of ...  

E-Print Network [OSTI]

Jun 28, 2007 ... Guaranteed Minimum-Rank Solutions of Linear Matrix Equations via Nuclear Norm Minimization. Benjamin Recht(brecht ***at*** caltech.edu)

Benjamin Recht

2007-06-28T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Microbial metatranscriptomics in a permanent marine oxygen minimum zone  

E-Print Network [OSTI]

Simultaneous characterization of taxonomic composition, metabolic gene content and gene expression in marine oxygen minimum zones (OMZs) has potential to broaden perspectives on the microbial and biogeochemical dynamics ...

Stewart, Frank J.

362

DOE CYBER SECURITY EBK: MINIMUM CORE COMPETENCY TRAINING REQUIREMENTS...  

Broader source: Energy.gov (indexed) [DOE]

DOE CYBER SECURITY EBK: MINIMUM CORE COMPETENCY TRAINING REQUIREMENTS DOE CYBER SECURITY EBK: CORE COMPETENCY TRAINING REQUIREMENTS: CA Cybersecurity Program Manager (CSPM...

363

Moving air for comfort  

E-Print Network [OSTI]

Brager, L. Zagreus. 2007, “Air movement preferences observed709-731. 9. Toftum, J. 2004. “Air movement – good or bad? ”Indoor Air 14, pp 40-45. 10. Gong, N. , K. Tham, A. Melikov,

Arens, Edward; Turner, Stephen; Zhang, Hui; Paliaga, Gwelen

2009-01-01T23:59:59.000Z

364

Feasibility of air capture  

E-Print Network [OSTI]

Capturing CO2 from air, referred to as Air Capture, is being proposed as a viable climate change mitigation technology. The two major benefits of air capture, reported in literature, are that it allows us to reduce the ...

Ranjan, Manya

2010-01-01T23:59:59.000Z

365

Equivalence in Ventilation and Indoor Air Quality  

SciTech Connect (OSTI)

We ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum ventilation rates without taking into account the impact of those rates on IAQ. Innovative ventilation management is often a desirable element of reducing energy consumption or improving IAQ or comfort. Variable ventilation is one innovative strategy. To use variable ventilation in a way that meets standards, it is necessary to have a method for determining equivalence in terms of either ventilation or indoor air quality. This study develops methods to calculate either equivalent ventilation or equivalent IAQ. We demonstrate that equivalent ventilation can be used as the basis for dynamic ventilation control, reducing peak load and infiltration of outdoor contaminants. We also show that equivalent IAQ could allow some contaminants to exceed current standards if other contaminants are more stringently controlled.

Sherman, Max; Walker, Iain; Logue, Jennifer

2011-08-01T23:59:59.000Z

366

Primary zone air proportioner  

DOE Patents [OSTI]

An air proportioner is provided for a liquid hydrocarbon fueled gas turbine of the type which is convertible to oil gas fuel and to coal gas fuel. The turbine includes a shell for enclosing the turbine, an air duct for venting air in said shell to a gasifier, and a fuel injector for injecting gasified fuel into the turbine. The air proportioner comprises a second air duct for venting air from the air duct for mixing with fuel from the gasifier. The air can be directly injected into the gas combustion basket along with the fuel from the injector or premixed with fuel from the gasifier prior to injection by the fuel injector.

Cleary, Edward N. G. (San Diego, CA)

1982-10-12T23:59:59.000Z

367

China Cools with Tighter RAC Standards  

E-Print Network [OSTI]

Program for Consumer Products: Central Air Conditioners andmost dominant product type in China today is the split air

Lin, Jiang; Rosenquist, Gregory

2006-01-01T23:59:59.000Z

368

DSM Electricity Savings Potential in the Buildings Sector in APP Countries  

E-Print Network [OSTI]

Packaged terminal air conditioners and heat pumps Warm-airheat pump efficiency is assumed to be equal to air

McNeil, MIchael

2011-01-01T23:59:59.000Z

369

Building Energy-Efficiency Best Practice Policies and Policy Packages  

E-Print Network [OSTI]

air sealing cracks; and installing programmable thermostats, energy-efficient replacement water heaters, heat pumps, air conditioners,

Levine, Mark

2014-01-01T23:59:59.000Z

370

7Name ________________________________ System Watts Energy source  

E-Print Network [OSTI]

, which will do work to move air in your air conditioner, or to keep food cold in your refrigerator. When

371

Algorithms to Compute Minimum Cycle Basis in Directed Graphs #  

E-Print Network [OSTI]

, . . . ,C d whose incidence vectors permit a unique linear combination of the incidence vector of any cycleAlgorithms to Compute Minimum Cycle Basis in Directed Graphs # Telikepalli Kavitha + Kurt Mehlhorn # Abstract We consider the problem of computing a minimum cycle basis in a di­ rected graph G with m arcs

Mehlhorn, Kurt

372

Approximate Minimum-Energy Multicasting in Wireless Ad Hoc Networks  

E-Print Network [OSTI]

and a set of destination nodes, the problem is to build a minimum-energy multicast tree for the requestApproximate Minimum-Energy Multicasting in Wireless Ad Hoc Networks Weifa Liang, Senior Member, IEEE Abstract--A wireless ad hoc network consists of mobile nodes that are equipped with energy

Liang, Weifa

373

Asymptotically minimum BER linear block precoders for MMSE equalisation  

E-Print Network [OSTI]

) [3]. For a general block transmission scheme, optimal detection requires a joint decisionAsymptotically minimum BER linear block precoders for MMSE equalisation S.S. Chan, T.N. Davidson and K.M. Wong Abstract: An asymptotically minimum bit error rate (BER) linear block precoder

Davidson, Tim

374

Approximating the Minimum Spanning Tree Weight in Sublinear Time  

E-Print Network [OSTI]

Approximating the Minimum Spanning Tree Weight in Sublinear Time #3; Bernard Chazelle y Ronitt a parameter 0 minimum span- ning tree in the graph and then grows \\local spanning trees" whose sizes are speci#12;ed by a stochastic process. From

Goldwasser, Shafi

375

Polynomial Time Algorithms for Minimum Energy Scheduling Philippe Baptiste1  

E-Print Network [OSTI]

algorithm for computing the minimum energy schedule when all jobs have unit length. 1 Introduction PowerPolynomial Time Algorithms for Minimum Energy Scheduling Philippe Baptiste1 , Marek Chrobak2 policies is to reduce the amount of energy consumed by computer systems while maintaining satisfactory

Chrobak, Marek

376

AiR surface: AiR surface 1  

E-Print Network [OSTI]

AiR surface: 1 PDA AiR surface 1 1: AiR surface () () 2 [1] [2] 3 AiR surface AiR surface surface surface surface 3.1 surface [3]( 3 ) surface 3.2 surface surface AiR surface 4 AiR surface surface AiR surface: Virtual Touch Panel

Tanaka, Jiro

377

2005 Status Report Savings Estimates for the ENERGY STAR(R) Voluntary Labeling Program  

E-Print Network [OSTI]

and Cooling - Furnace (Gas or Oil) - Central Air Conditioner - Air-Source Heat Pump - Geothermaland Cooling - Furnaces (Gas or Oil) - Central Air Conditioners - Air-Source Heat Pumps - Geothermaland Cooling - Furnaces (Gas or Oil) - Central Air Conditioners - Air-Source Heat Pumps - Geothermal

Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla

2006-01-01T23:59:59.000Z

378

Air Pollution Spring 2010  

E-Print Network [OSTI]

ATS 555 Air Pollution Spring 2010 T Th 11:00 ­ 12:15, NESB 101 Instructor: Prof. Sonia Kreidenweis an understanding of types and sources of air pollution. 2. Examine concentrations of air pollutants and their effects on health and welfare. Review regulations governing air pollution. 3. Examine the meteorological

379

Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature?  

E-Print Network [OSTI]

The supply air temperature set point for a singleduct constant air volume air handling unit (AHU) system is often reset based on either return air temperature or outside air temperature in order to reduce simultaneous cooling and heating energy...

Wei, G.; Turner, W. D.; Claridge, D.; Liu, M.

2002-01-01T23:59:59.000Z

380

White Paper on Energy Efficiency Status of Energy-Using Products in China (2011)  

E-Print Network [OSTI]

commercial air conditioning products came to a standstill inIn 2010, the room air conditioner products market in oursales volume of air conditioner products in our country have

Zhou, Nan

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Arnold Schwarzenegger Preserving California's  

E-Print Network [OSTI]

......................................................................................107 A-5 Standards for Freezers That Are Consumer Products Canned and Bottled Beverage Vending Machines, and Wine Chillers That Are Not Consumer Products....................................................112 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner

382

Analysis of Potential Energy Saving and CO2 Emission Reduction of Home Appliances and Commercial Equipments in China  

E-Print Network [OSTI]

Multi-connected air condition (heat pump) unit Chiller VL VLmotors and air conditioners are followed by heat pump waterRefrigerator Heat Pump Water Heater Air Conditioner Electric

Zhou, Nan

2010-01-01T23:59:59.000Z

383

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2010  

E-Print Network [OSTI]

Commercial furnaces and boilers, air conditioners and heat pumps, and water heatersCOMMERCIAL & INDUSTRIAL EPACT 1992 Electric Motors EPACT 1992 Warm Air Furnaces EPACT 1992 Packaged Boilers EPACT 1992 Air Conditioners and Heat Pumps EPACT 1992 Water Heaters,

Meyers, Stephen

2013-01-01T23:59:59.000Z

384

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 through 2012  

E-Print Network [OSTI]

Commercial furnaces and boilers, air conditioners and heat pumps, and water heatersCOMMERCIAL & INDUSTRIAL EPACT 1992 Electric Motors EPACT 1992 Warm Air Furnaces EPACT 1992 Packaged Boilers EPACT 1992 Air Conditioners and Heat Pumps EPACT 1992 Water Heaters,

Meyers, Stephen

2013-01-01T23:59:59.000Z

385

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2011  

E-Print Network [OSTI]

Commercial furnaces and boilers, air conditioners and heat pumps, and water heatersCOMMERCIAL & INDUSTRIAL EPACT 1992 Electric Motors EPACT 1992 Warm Air Furnaces EPACT 1992 Packaged Boilers EPACT 1992 Air Conditioners and Heat Pumps EPACT 1992 Water Heaters,

Meyers, Stephen

2013-01-01T23:59:59.000Z

386

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2013  

E-Print Network [OSTI]

Commercial furnaces and boilers, air conditioners and heat pumps, and water heatersCOMMERCIAL & INDUSTRIAL EPACT 1992 Electric Motors EPACT 1992 Warm Air Furnaces EPACT 1992 Packaged Boilers EPACT 1992 Air Conditioners and Heat Pumps EPACT 1992 Water Heaters,

, Stephen Meyers

2014-01-01T23:59:59.000Z

387

Tree-ring reconstruction of maximum and minimum temperatures  

E-Print Network [OSTI]

, minimum temperatures, diurnal temperature range, changing tree-ring/climate relationships, b; Vaganov et al. 1999; Bar- ber et al. 2000; Lloyd, Fastie 2002). Similar changes during investigations of tree- ring growth/climate relationships in interior British Columbia (BC

388

Minimum Purchase Price Regulations (Prince Edward Island, Canada)  

Broader source: Energy.gov [DOE]

The Minimum Purchase Price Regulations establish the price which utilities must pay for power produced by large-scale renewable energy generators – that is those capable of producing more than 100...

389

Optimization Online - On the complexity of maximizing the minimum ...  

E-Print Network [OSTI]

Jan 18, 2010 ... ... minimum total Shannon capacity of any mobile user in the system. ... Category 1: Applications -- OR and Management Sciences (Telecommunications ) ... Address: Department of Mathematics, Royal Institute of Technology, ...

Mikael Fallgren

2010-01-18T23:59:59.000Z

390

Planning of Minimum-Time Trajectories for Robot Arms  

E-Print Network [OSTI]

The minimum-time for a robot arm has been a longstanding and unsolved problem of considerable interest. We present a general solution to this problem that involves joint-space tesselation, a dynamic time-scaling ...

Sahar, Gideon

1984-11-01T23:59:59.000Z

391

affecting minimum alveolar: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

close to the observed minimum mass. The Hubble mass can also be predicted. It is suggested that assumption 1 above could be tested using a cyclotron to accelerate particles...

392

TOWARD THE MINIMUM INNER EDGE DISTANCE OF THE HABITABLE ZONE  

E-Print Network [OSTI]

We explore the minimum distance from a host star where an exoplanet could potentially be habitable in order not to discard close-in rocky exoplanets for follow-up observations. We find that the inner edge of the Habitable ...

Zsom, Andras

393

Upper bounds on minimum distance of nonbinary quantum stabilizer codes  

E-Print Network [OSTI]

The most popular class of quantum error correcting codes is stabilizer codes. Binary quantum stabilizer codes have been well studied, and Calderbank, Rains, Shor and Sloane (July 1998) have constructed a table of upper bounds on the minimum distance...

Kumar, Santosh

2005-11-01T23:59:59.000Z

394

Minimum Stream Flow and Water Sale Contracts (Indiana)  

Broader source: Energy.gov [DOE]

The Indiana Natural Resources Commission may provide certain minimum quantities of stream flow or sell water on a unit pricing basis for water supply purposes from the water supply storage in...

395

Determine Minimum Silver Flake Addition to GCM for Iodine Loaded AgZ  

SciTech Connect (OSTI)

The minimum amount of silver flake required to prevent loss of I{sub 2} during sintering in air for a SNL Glass Composite Material (GCM) Waste Form containing AgI-MOR (ORNL, 8.7 wt%) was determined to be 1.1 wt% Ag. The final GCM composition prior to sintering was 20 wt% AgI-MOR, 1.1 wt% Ag, and 80 wt% Bi-Si oxide glass. The amount of silver flake needed to suppress iodine loss was determined using thermo gravimetric analysis with mass spectroscopic off-gas analysis. These studies found that the ratio of silver to AgI-MOR required is lower in the presence of the glass than without it. Therefore an additional benefit of the GCM is that it serves to inhibit some iodine loss during processing. Alternatively, heating the AgI-MOR in inert atmosphere instead of air allowed for densified GCM formation without I{sub 2} loss, and no necessity for the addition of Ag. The cause of this behavior is found to be related to the oxidation of the metallic Ag to Ag{sup +} when heated to above ~300{degrees}C in air. Heating rate, iodine loading levels and atmosphere are the important variables that determine AgI migration and results suggest that AgI may be completely incorporated into the mordenite structure by the 550{degrees}C sintering temperature.

Terry J. Garino; Tina M. Nenoff; Mark A. Rodriguez

2014-04-01T23:59:59.000Z

396

A P P L I A N C E EFFICIENCY REGULATIONS  

E-Print Network [OSTI]

Test Methods...........................40 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump............................................65 B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps..................67 B, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods ......................41 C

397

A P P L I A N C E CEC 400-2005-012  

E-Print Network [OSTI]

Test Methods........................... 44 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump ............................................ 72 B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps................... 74, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods....................... 45 C

398

A P P L I A N C E August, 2003  

E-Print Network [OSTI]

Test Methods........................... 40 B-1 Room Air Conditioner, Room Air-Conditioning Heat Pump ............................................ 65 B-2 Standards for Room Air Conditioners and Room Air-Conditioning Heat Pumps................... 67, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods....................... 41 C

399

Temperature, Power, and Makespan Aware Dependent Task Scheduling for Data Zheng Li, Li Wang, and Shangping Ren  

E-Print Network [OSTI]

conditioners are used to supply cold air and remove heat from the center. The supplied air must be cold enough of a server, the lower the temperature of cooling air provided by the air conditioner has to be. Unfortunately, as pointed out by Moore [4], lowing the room air conditioner's working temperature degrades its capability

Quan, Gang

400

Air drilling has some pluses for horizontal wells  

SciTech Connect (OSTI)

Drilling horizontal wells with air as the circulating medium is not a common practice; however, air has come distinct advantages over drilling mud. They are: Significant increase in rate of penetration which leads to shorter drilling time. Elimination of lost circulation problems, especially in areas of very low bottom hole pressures. Continual drill stem test of potential producing formations. Minimal damage to the formation. Unfortunately, there are some disadvantages to drilling with air. Downhole motor life is shorter and less predictable. No measurement-while-drilling (MWD) system is currently available that will work consistently in air drilling environments. Hole cleaning is a problem at inclinations above 50{degree}. The horizontal section length is reduced because of the increased friction (drag) between the drillstring and borehole. The types of lithologies and targets are limited. Several horizontal wells have been successfully drilled with air or foam since 1986. At a minimum, operators drill the horizontal section with air or foam to eliminate lost circulation problems in low pressure or partially depleted reservoirs and to reduce formation damage due to drilling fluid invasion. However, problems have been encountered in drilling horizontal wells with air. Not all of the problems are unique to air drilling, but some may be exaggerated by the conditions in an air-drilled hole.

Carden, R.S. (Grace, Shursen, Moore and Associates, Inc., Amarillo, TX (US))

1991-04-08T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Aesculap, Inc. Air Products  

E-Print Network [OSTI]

Aesculap, Inc. Air Products Air Products Foundation Alaric Compliance Services, LLC Alvin H. Butz & Herger, Inc. Sodexo Campus Services Sodexo Inc. and Affiliates Stupp Bros., Inc. Sugarbush Products, Inc

Napier, Terrence

402

General Air Permits (Louisiana)  

Broader source: Energy.gov [DOE]

Any source, including a temporary source, which emits or has the potential to emit any air contaminant requires an air permit. Facilities with potential emissions less than 5 tons per year of any...

403

Healthy Air Act (Maryland)  

Broader source: Energy.gov [DOE]

The Maryland Healthy Air Act was developed with the purpose of bringing Maryland into attainment with the National Ambient Air Quality Standards (NAAQS) for ozone and fine particulate matter by the...

404

Air pollution and infant mortality from pneumonia  

SciTech Connect (OSTI)

This study examines the relationship between air pollution, measured as concentration of suspended particulates in the atmosphere, and infant mortality due to pneumonia in the metropolitan area of Rio de Janeiro. Multiple linear regression (progressive or stepwise method) was used to analyze infant mortality due to pneumonia, diarrhea, and all causes in 1980, by geographic area, income level, and degree of contamination. While the variable proportion of families with income equivalent to more than two minimum wages was included in the regressions corresponding to the three types of infant mortality, the average contamination index had a statistically significant coefficient (b = 0.2208; t = 2.670; P = 0.0137) only in the case of mortality due to pneumonia. This would suggest a biological association, but, as in any ecological study, such conclusions should be viewed with caution. The authors believe that air quality indicators are essential to consider in studies of acute respiratory infections in developing countries.

Penna, M.L.; Duchiade, M.P. (Instituto de Medicina Social, Universidad del Estado del Rio de Janeiro (Brasil))

1991-03-01T23:59:59.000Z

405

on man, nature & air pollution  

E-Print Network [OSTI]

on man, nature & air pollution About three decades ago, itand episodes of air pollution the following summer. Wetthe increase in air pollution. This hypothesis generated

Finlayson-Pitts, Barbara J

2008-01-01T23:59:59.000Z

406

NREL's Energy-Saving Technology for Air Conditioning Cuts Peak Power Loads Without Using Harmful Refrigerants (Fact Sheet)  

SciTech Connect (OSTI)

This fact sheet describes how the DEVAP air conditioner was invented, explains how the technology works, and why it won an R&D 100 Award. Desiccant-enhanced evaporative (DEVAP) air-conditioning will provide superior comfort for commercial buildings in any climate at a small fraction of the electricity costs of conventional air-conditioning equipment, releasing far less carbon dioxide and cutting costly peak electrical demand by an estimated 80%. Air conditioning currently consumes about 15% of the electricity generated in the United States and is a major contributor to peak electrical demand on hot summer days, which can lead to escalating power costs, brownouts, and rolling blackouts. DEVAP employs an innovative combination of air-cooling technologies to reduce energy use by up to 81%. DEVAP also shifts most of the energy needs to thermal energy sources, reducing annual electricity use by up to 90%. In doing so, DEVAP is estimated to cut peak electrical demand by nearly 80% in all climates. Widespread use of this cooling cycle would dramatically cut peak electrical loads throughout the country, saving billions of dollars in investments and operating costs for our nation's electrical utilities. Water is already used as a refrigerant in evaporative coolers, a common and widely used energy-saving technology for arid regions. The technology cools incoming hot, dry air by evaporating water into it. The energy absorbed by the water as it evaporates, known as the latent heat of vaporization, cools the air while humidifying it. However, evaporative coolers only function when the air is dry, and they deliver humid air that can lower the comfort level for building occupants. And even many dry climates like Phoenix, Arizona, have a humid season when evaporative cooling won't work well. DEVAP extends the applicability of evaporative cooling by first using a liquid desiccant-a water-absorbing material-to dry the air. The dry air is then passed to an indirect evaporative cooling stage, in which the incoming air is in thermal contact with a moistened surface that evaporates the water into a separate air stream. As the evaporation cools the moistened surface, it draws heat from the incoming air without adding humidity to it. A number of cooling cycles have been developed that employ indirect evaporative cooling, but DEVAP achieves a superior efficiency relative to its technological siblings.

Not Available

2012-07-01T23:59:59.000Z

407

Air Products effective way  

E-Print Network [OSTI]

PE O A e s a b O T A O ENNST Overview Air Products effective way standard me Departm Shipping has recently y of shipping eans. Air Pro ontainer that es of this pro onduct mark eep accelera eep the cost tilize widely a earch and m m visited Air er needs wer model was cr m approache ms

Demirel, Melik C.

408

Air Quality Chapter Outline  

E-Print Network [OSTI]

Chapter 30 Air Quality Chapter Outline 1 Overview 2 1.1 Hazards / Impacts 2 1.2 Exposure Sources 3 Manual Chapter 30: Air Quality 7 References 20 8 Implementation 21 9 Ownership 22 1 Overview SLAC operations produce a wide range of air emissions. Sources of emissions include standard equipment

Wechsler, Risa H.

409

MAD-AIR  

E-Print Network [OSTI]

with stress- related illness rather than the anwr that spells RELIEF. Air flow in, through ad arourd a house is an important concern in the building we call haw. !lb enhance air flow and change the various corditions or properties of the air, a variety...

Tooley, J. J.; Moyer, N. A.

1989-01-01T23:59:59.000Z

410

Calendar Year 2007 Program Benefits for U.S. EPA Energy Star Labeled Products: Expanded Methodology  

E-Print Network [OSTI]

Air Conditioners and Air Source Heat Pumps. UnpublishedManufacturers air source heat pump American Society ofconditioning, ASHP = air source heat pump, HP = heat pump,

Sanchez, Marla

2010-01-01T23:59:59.000Z

411

Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles  

E-Print Network [OSTI]

temperature at supply air temperature setpoint. Mechanical cooling is always required when outside air temperature is higher than the supply air temperature setpoint. Generally the supply air temperature setpoint is set at 55°F for space humidity control...

Xu, K.; Liu, M.; Wang, G.; Wang, Z.

2007-01-01T23:59:59.000Z

412

Mitigating the Impacts of Uncontrolled Air Flow on Indoor Environmental Quality and Energy Demand in Non-Residential Buildings  

SciTech Connect (OSTI)

This multi-faceted study evaluated several aspects of uncontrolled air flows in commercial buildings in both Northern and Southern climates. Field data were collected from 25 small commercial buildings in New York State to understand baseline conditions for Northern buildings. Laboratory wall assembly testing was completed at Syracuse University to understand the impact of typical air leakage pathways on heat and moisture transport within wall assemblies for both Northern and Southern building applications. The experimental data from the laboratory tests were used to verify detailed heat and moisture (HAM) simulation models that could be used to evaluate a wider array of building applications and situations. Whole building testing at FSEC's Building Science Laboratory (BSL) systematically evaluated the energy and IAQ impacts of duct leakage with various attic and ceiling configurations. This systematic test carefully controlled all aspects of building performance to quantify the impact of duct leakage and unbalanced flow. The newest features of the EnergyPlus building simulation tool were used to model the combined impacts of duct leakage, ceiling leakage, unbalanced flows, and air conditioner performance. The experimental data provided the basis to validate the simulation model so it could be used to study the impact of duct leakage over a wide range of climates and applications. The overall objective of this project was to transfer work and knowledge that has been done on uncontrolled air flow in non-residential buildings in Florida to a national basis. This objective was implemented by means of four tasks: (1) Field testing and monitoring of uncontrolled air flow in a sample of New York buildings; (2) Detailed wall assembly laboratory measurements and modeling; (3) Whole building experiments and simulation of uncontrolled air flows; and (4) Develop and implement training on uncontrolled air flows for Practitioners in New York State.

Hugh I. Henderson; Jensen Zhang; James B. Cummings; Terry Brennan

2006-07-31T23:59:59.000Z

413

Ninety - Two Percent Minimum Heater Efficiency By 1980  

E-Print Network [OSTI]

exchangers used to transfer heat to tqe com- I bustion air are divided into two groups. IndiIlect ! heat exchangers called "regenerative" types an~ direct heat exchangers called "recuperative" types. In a regenerative air heater, heat is transferred i...~duced I draft, air preheat system. This system can ac~omodate either a regenerative or recuperative air heater and ! Fig. 5 - Heat recovery systems. 857 ESL-IE-80-04-157 Proceedings from the Second Industrial Energy Technology Conference Houston, TX...

Mieth, H. C.; Hardie, J. E.

1980-01-01T23:59:59.000Z

414

Air to Air Communication Protocol Arjan Durresi1  

E-Print Network [OSTI]

1 Air to Air Communication Protocol Arjan Durresi1 , Vamsi Paruchuri1 , Leonard Barolli2 and Raj. Louis, MO 63130, USA 314-935-4963, jain@cse.wustl.edu Abstract--We present Air to Air Communication (AAC........................................................2 3. AIR TO AIR COMMUNICATION..............................3 4. SIMULATIONS

Jain, Raj

415

ORIGINAL ARTICLE Ambient Air Pollution  

E-Print Network [OSTI]

ORIGINAL ARTICLE Ambient Air Pollution and Cardiovascular Emergency Department Visits Kristi Busico ambient air pollutants and cardiovascular disease (CVD), the roles of the physicochemical components the relation between ambient air pollution and cardiovascular conditions using ambient air quality data

Mulholland, James A.

416

E-Print Network 3.0 - antagonists minimum safety Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

minimum safety Search Powered by Explorit Topic List Advanced Search Sample search results for: antagonists minimum safety Page: << < 1 2 3 4 5 > >> 1 Microscopic Kinetics and...

417

New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy  

SciTech Connect (OSTI)

Approximately ten percent of the energy consumed in U.S. commercial buildings is used by HVAC systems to condition outdoor ventilation air. Reducing ventilation rates would be a simple and broadly-applicable energy retrofit option, if practical counter measures were available that maintained acceptable concentrations of indoor-generated air pollutants. The two general categories of countermeasures are: 1) indoor pollutant source control, and 2) air cleaning. Although pollutant source control should be used to the degree possible, source control is complicated by the large number and changing nature of indoor pollutant sources. Particle air cleaning is already routinely applied in commercial buildings. Previous calculations indicate that particle filtration consumes only 10percent to 25percent of the energy that would otherwise be required to achieve an equivalent amount of particle removal with ventilation. If cost-effective air cleaning technologies for volatile organic compounds (VOCs) were also available, outdoor air ventilation rates could be reduced substantially and broadly in the commercial building stock to save energy. The research carried out in this project focuses on developing novel VOC air cleaning technologies needed to enable energy-saving reductions in ventilation rates. The minimum required VOC removal efficiency to counteract a 50percent reduction in ventilation rate for air cleaning systems installed in the HVAC supply airstream is modest (generally 20percent or less).

Sidheswaran, Meera; Destaillats, Hugo; Sullivan, Douglas P.; Fisk, William J.

2010-10-27T23:59:59.000Z

418

The minimum distance of classical and quantum turbo-codes  

E-Print Network [OSTI]

We present a theory of quantum stabilizer turbo-encoders with unbounded minimum distance. This theory is presented under a framework common to both classical and quantum turbo-encoding theory. The main conditions to have an unbounded minimum distance are that the inner seed encoder has to be recursive, and either systematic or with a totally recursive truncated decoder. This last condition has been introduced in order to obtain a theory viable in the quantum stabilizer case, since it was known that in this case the inner seed encoder could not be recursive and systematic in the same time.

Abbara, Mamdouh

2011-01-01T23:59:59.000Z

419

The minimum distance of classical and quantum turbo-codes  

E-Print Network [OSTI]

We present a theory of quantum stabilizer turbo-encoders with unbounded minimum distance. This theory is presented under a framework common to both classical and quantum turbo-encoding theory. The main conditions to have an unbounded minimum distance are that the inner seed encoder has to be recursive, and either systematic or with a totally recursive truncated decoder. This last condition has been introduced in order to obtain a theory viable in the quantum stabilizer case, since it was known that in this case the inner seed encoder could not be recursive and systematic in the same time.

Mamdouh Abbara; Jean-Pierre Tillich

2011-09-01T23:59:59.000Z

420

Proposal for a Vehicle Level Test Procedure to Measure Air Conditioning Fuel Use  

SciTech Connect (OSTI)

The air-conditioning (A/C) compressor load significantly impacts the fuel economy of conventional vehicles and the fuel use/range of plug-in hybrid electric vehicles (PHEV). A National Renewable Energy Laboratory (NREL) vehicle performance analysis shows the operation of the air conditioner reduces the charge depletion range of a 40-mile range PHEV from 18% to 30% in a worst case hot environment. Designing for air conditioning electrical loads impacts PHEV and electric vehicle (EV) energy storage system size and cost. While automobile manufacturers have climate control procedures to assess A/C performance, and the U.S. EPA has the SCO3 drive cycle to measure indirect A/C emissions, there is no automotive industry consensus on a vehicle level A/C fuel use test procedure. With increasing attention on A/C fuel use due to increased regulatory activities and the development of PHEVs and EVs, a test procedure is needed to accurately assess the impact of climate control loads. A vehicle thermal soak period is recommended, with solar lamps that meet the SCO3 requirements or an alternative heating method such as portable electric heaters. After soaking, the vehicle is operated over repeated drive cycles or at a constant speed until steady-state cabin air temperature is attained. With this method, the cooldown and steady-state A/C fuel use are measured. This method can be run at either different ambient temperatures to provide data for the GREEN-MAC-LCCP model temperature bins or at a single representative ambient temperature. Vehicles with automatic climate systems are allowed to control as designed, while vehicles with manual climate systems are adjusted to approximate expected climate control settings. An A/C off test is also run for all drive profiles. This procedure measures approximate real-world A/C fuel use and assess the impact of thermal load reduction strategies.

Rugh, J. P.

2010-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Simplified configuration for the combustor of an oil burner using a low pressure, high flow air-atomizing nozzle  

DOE Patents [OSTI]

The invention relates to clean burning of fuel oil with air. More specifically, to a fuel burning combustion head using a low-pressure, high air flow atomizing nozzle so that there will be a complete combustion of oil resulting in a minimum emission of pollutants. The improved fuel burner uses a low pressure air atomizing nozzle that does not result in the use of additional compressors or the introduction of pressurized gases downstream, nor does it require a complex design. Inventors:

Butcher, Thomas A. (Port Jefferson, NY); Celebi, Yusuf (Middle Island, NY); Fisher, Leonard (Colrain, MA)

2000-09-15T23:59:59.000Z

422

Implementing Minimum Cycle Basis algorithms Kurt Mehlhorn and Dimitrios Michail  

E-Print Network [OSTI]

Implementing Minimum Cycle Basis algorithms Kurt Mehlhorn and Dimitrios Michail Max consider the problem of computing a mini- mum cycle basis of an undirected graph G = (V, E) with n vertices in a significant speedup. Based on our experimental observations, we combine the two fundamen- tally different

Mehlhorn, Kurt

423

Effect of mechanical parameters on dielectric elastomer minimum energy structures  

E-Print Network [OSTI]

Effect of mechanical parameters on dielectric elastomer minimum energy structures Jun Shintake energy structures Jun Shintake*a,b , Samuel Rosseta , Dario Floreanob , Herbert R. Sheaa a Microsystems for Space Technologies Laboratory, Ecole Polytechnique Fédérale de Lausanne (EPFL), Neuchâtel, Switzerland b

Floreano, Dario

424

A minimum entropy principle of high order schemes for gas ...  

E-Print Network [OSTI]

The entropy solutions of the compressible Euler equations satisfy a minimum principle for the specific ... where ? is the density, u is the velocity, m is the momentum, E is the total energy and p is the pressure. ... can enforce this condition without destroying conservation. .... achieved under a standard CFL condition ? (|u| + c) ...

2011-09-15T23:59:59.000Z

425

On the Minimum Load Coloring Problem --Extended Abtract--  

E-Print Network [OSTI]

# such that the maximum load, l # := max{r# , b #}, is minimized. In the following we shall skip the term ``maximumOn the Minimum Load Coloring Problem --Extended Abtract-- Nitin Ahuja 1 , Andreas Baltz 2 Abstract. Given a graph G = (V, E) with n vertices, m edges and maximum vertex degree #, the load

Doerr, Benjamin

426

Predicting Daily Net Radiation Using Minimum Climatological Data1  

E-Print Network [OSTI]

Predicting Daily Net Radiation Using Minimum Climatological Data1 S. Irmak, M.ASCE2 ; A. Irmak3 ; J for predicting daily Rn have been widely used. However, when the paucity of detailed climatological data with National Weather Service climatological datasets that only record Tmax and Tmin on a regular basis. DOI: 10

427

Optimizing rotational acceleration curves for minimum energy use in electric  

E-Print Network [OSTI]

Optimizing rotational acceleration curves for minimum energy use in electric motors. 12/15/06 Fall the optimal efficiency of a motor for any input values of motor constants, distance, or time. In every of the inspiration to find which rotational acceleration curve for the used motors would be most efficient. We really

Ruina, Andy L.

428

Localized Minimum-Energy Broadcasting for Wireless Multihop Networks  

E-Print Network [OSTI]

tree. We then observe that, for very dense networks, it is more energy-efficient to reach more than oneLocalized Minimum-Energy Broadcasting for Wireless Multihop Networks with Directional Antennas, and Carmen M. Yago Abstract--There are a number of proposals to achieve energy-efficient broadcasting

Stojmenovic, Ivan

429

Minimum-Hot-Spot Query Trees for Wireless Sensor Networks  

E-Print Network [OSTI]

an energy- efficient query routing tree. (a) Energy harvesting for battery- less nodes for the (b) Voltree to the querying node. Energy-efficient query routing trees are needed in a plethora of systems such as PeopleMinimum-Hot-Spot Query Trees for Wireless Sensor Networks Georgios Chatzimilioudis Dept

Zeinalipour, Demetris

430

The"minimum information about an environmental sequence" (MIENS) specification  

SciTech Connect (OSTI)

We present the Genomic Standards Consortium's (GSC) 'Minimum Information about an ENvironmental Sequence' (MIENS) standard for describing marker genes. Adoption of MIENS will enhance our ability to analyze natural genetic diversity across the Tree of Life as it is currently being documented by massive DNA sequencing efforts from myriad ecosystems in our ever-changing biosphere.

Yilmaz, P.; Kottmann, R.; Field, D.; Knight, R.; Cole, J.R.; Amaral-Zettler, L.; Gilbert, J.A.; Karsch-Mizrachi, I.; Johnston, A.; Cochrane, G.; Vaughan, R.; Hunter, C.; Park, J.; Morrison, N.; Rocca-Serra, P.; Sterk, P.; Arumugam, M.; Baumgartner, L.; Birren, B.W.; Blaser, M.J.; Bonazzi, V.; Bork, P.; Buttigieg, P. L.; Chain, P.; Costello, E.K.; Huot-Creasy, H.; Dawyndt, P.; DeSantis, T.; Fierer, N.; Fuhrman, J.; Gallery, R.E.; Gibbs, R.A.; Giglio, M.G.; Gil, I. San; Gonzalez, A.; Gordon, J.I.; Guralnick, R.; Hankeln, W.; Highlander, S.; Hugenholtz, P.; Jansson, J.; Kennedy, J.; Knights, D.; Koren, O.; Kuczynski, J.; Kyrpides, N.; Larsen, R.; Lauber, C.L.; Legg, T.; Ley, R.E.; Lozupone, C.A.; Ludwig, W.; Lyons, D.; Maguire, E.; Methe, B.A.; Meyer, F.; Nakieny, S.; Nelson, K.E.; Nemergut, D.; Neufeld, J.D.; Pace, N.R.; Palanisamy, G.; Peplies, J.; Peterson, J.; Petrosino, J.; Proctor, L.; Raes, J.; Ratnasingham, S.; Ravel, J.; Relman, D.A.; Assunta-Sansone, S.; Schriml, L.; Sodergren, E.; Spor, A.; Stombaugh, J.; Tiedje, J.M.; Ward, D.V.; Weinstock, G.M.; Wendel, D.; White, O.; Wikle, A.; Wortman, J.R.; Glockner, F.O.; Bushman, F.D.; Charlson, E.; Gevers, D.; Kelley, S.T.; Neubold, L.K.; Oliver, A.E.; Pruesse, E.; Quast, C.; Schloss, P.D.; Sinha, R.; Whitely, A.

2010-10-15T23:59:59.000Z

431

Jamming-Aware Minimum Energy Routing in Wireless Networks  

E-Print Network [OSTI]

1 Jamming-Aware Minimum Energy Routing in Wireless Networks Azadeh Sheikholeslami, Majid Ghaderi; however, energy-aware routing in the presence of active adversary (jammers) has not been considered. We. There has been some study of energy-aware ad hoc routing protocols in the literature [13], [14], [15], [16

Goeckel, Dennis L.

432

BLIND DECONVOLUTION WITH MINIMUM RENYI'S ENTROPY Deniz Erdogmus1  

E-Print Network [OSTI]

BLIND DECONVOLUTION WITH MINIMUM RENYI'S ENTROPY Deniz Erdogmus1 , Jose C. Principe1 , Luis Vielva2-mail: [deniz , principe]@cnel.ufl.edu, luis@dicom.unican.es ABSTRACT Blind techniques attract the attention, from communications to control systems. Blind deconvolution is a problem that has been investigated

Slatton, Clint

433

The Minimum Constraint Removal Problem with Three Robotics Applications  

E-Print Network [OSTI]

The Minimum Constraint Removal Problem with Three Robotics Applications Kris Hauser Abstract on three example applications: generating human-interpretable excuses for failure, motion planning under their failures. · In human-robot interaction, semantically meaningful explanations would help people diagnose

Indiana University

434

The Minimum Constraint Removal Problem with Three Robotics Applications  

E-Print Network [OSTI]

The Minimum Constraint Removal Problem with Three Robotics Applications Kris Hauser September 13 strategies. It is demonstrated on three example applications: gener- ating human-interpretable excuses, then they provide no explanation for the failure. For several applications, it would be useful for planners

Indiana University

435

Interior Architecture Minor Tracking Sheet Total Minimum Credits: 26  

E-Print Network [OSTI]

Interior Architecture Minor Tracking Sheet Total Minimum Credits: 26 Minor standing is prerequisite architecture studio course is required for architecture majors enrolled in the interior architecture minor (1 is required for Architecture majors): IARC 484 Interior Design Studio (6), IARC 486 Furniture

436

Architecture Minor Tracking Sheet Total Minimum Credits: 26  

E-Print Network [OSTI]

Architecture Minor Tracking Sheet Total Minimum Credits: 26 Minor standing is prerequisite Notes: Required courses in one's major will not count for the minor with one exception: 1 architecture studio course is required for interior architecture majors enrolled in the architecture minor, and this studio

437

Optimum Wire Tapering for Minimum Power Dissipation in RLC Interconnects  

E-Print Network [OSTI]

tapering is shown to reduce the (a CMOS inverter) with the driver (a CMOS inverter). The power dissipatedOptimum Wire Tapering for Minimum Power Dissipation in RLC Interconnects Magdy A. El-Moursy and Eby G. Friedman Department of Electrical and Computer Engineering University of Rochester Rochester, New

Friedman, Eby G.

438

Requirements: A minimum of 15 PSYC credits, including  

E-Print Network [OSTI]

» Three other 2000-3000-level PSYC courses (any area) No more than 3 credits of PSYC 3889 or 3999 canRequirements: A minimum of 15 PSYC credits, including: » One Area I course » One Area II course) ___2100 (Principles of Research in Psychology) Area I. Social, Developmental, Clinical, & Industrial

Alpay, S. Pamir

439

Personal continuous air monitor  

DOE Patents [OSTI]

A personal continuous air monitor capable of giving immediate warning of the presence of radioactivity has a filter/detector head to be worn in the breathing zone of a user, containing a filter mounted adjacent to radiation detectors, and a preamplifier. The filter/detector head is connected to a belt pack to be worn at the waist or on the back of a user. The belt pack contains a signal processor, batteries, a multichannel analyzer, a logic circuit, and an alarm. An air pump also is provided in the belt pack for pulling air through the filter/detector head by way of an air tube.

Morgan, Ronald G. (Los Alamos, NM); Salazar, Samuel A. (Albuquerque, NM)

2000-01-01T23:59:59.000Z

440

Environmental Quality: Air (Louisiana)  

Broader source: Energy.gov [DOE]

The Department of Environmental Quality regulates air quality in Louisiana. The Department has an established a fee system for funding the monitoring, investigation and other activities required...

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Golden Opportunity: Proposed Penalty (2014-CE-20003)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that Golden Opportunity, Inc. failed to certify room air conditioners, central air conditioners/heat pumps, and residential clothes washers as compliant with the applicable energy conservation standards.

442

Using National Survey Data to Estimate Lifetimes of Residential Appliances  

E-Print Network [OSTI]

conditioners, heat pumps, furnaces, boilers, water heaters,conditioners, heat pumps, furnaces, boilers, water heaters,Water Heater, Gas Room Air- Conditioning Central Air- Conditioning Boiler, Gas Furnace, Gas Heat Pump *

Lutz, James D.

2013-01-01T23:59:59.000Z

443

Research on Convective Heat Transfer and Mass Transfer of the Evaporator in Micro/Mini-Channel  

E-Print Network [OSTI]

on the reviewers on the present household air conditioners, the potential requirements for new heat transfer enhancement used for household air conditioners are discussed. Investigations on condensation and boiling of refrigerants in mini/micro channels have...

Su, J.; Li, J.

2006-01-01T23:59:59.000Z

444

http://pic.sagepub.com/ Engineering Science  

E-Print Network [OSTI]

, i.e. computer room air conditioner fan failure, server fan failure, and workload misconfiguration events such as computer room air conditioner (CRAC) fan failure, server fan failure, and workload

Pompili, Dario

445

Technical Highlights April 2013 Fuels, Engines, and Emissions Research Center (FEERC) Staff Organize and Participate in Multiple Events  

E-Print Network [OSTI]

of the papers on the effects of air conditioner use on real-world fuel economy received special coverage Congress (April 16­18). A paper on the fuel economy penalties for air #12;conditioner use and driving

446

Topic 4: Demand Response A.H. MohsenianRad (U of T) 1Networking and Distributed Systems  

E-Print Network [OSTI]

: · The utility has remote access to certain load of users · Air conditioner · Water heater. · It remotely turns installed DLC switches on air conditioner #12;DLC Example Dr. Hamed Mohsenian-Rad Texas Tech University

Mohsenian-Rad, Hamed

447

Name of TMO ODSS1 ODSS2  

E-Print Network [OSTI]

Heating System Camera Window & Curtain LightFan Air Conditioner , , #12;Platform : Intel X86 /W indows XP /Windows 2000 Server CPU : Pentium 4-700MhzHome Server TMO Air Conditioner TMO Heater TMO Heater TMO Fan

Joo, Su-Chong

448

International MODIS and AIRS processing package: AIRS products and applications  

E-Print Network [OSTI]

International MODIS and AIRS processing package: AIRS products and applications Elisabeth Weisz presented and discussed in this paper demonstrate that the IMAPP AIRS retrieval product is rigorously parameters from the operational AIRS L2 product and data from other instruments. Keywords: AIRS, IMAPP

Li, Jun

449

AIR SEALING Seal air leaks and save energy!  

E-Print Network [OSTI]

AIR SEALING Seal air leaks and save energy! W H A T I S A I R L E A K A G E ? Ventilation is fresh air that enters a house in a controlled manner to exhaust excess moisture and reduce odors and stuffiness. Air leakage, or infiltration, is outside air that enters a house uncontrollably through cracks

Oak Ridge National Laboratory

450

Recirculating electric air filter  

DOE Patents [OSTI]

An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

Bergman, W.

1985-01-09T23:59:59.000Z

451

Portable oven air circulator  

DOE Patents [OSTI]

A portable air circulating apparatus for use in cooking ovens which is used to create air currents in the oven which transfer heat to cooking foodstuffs to promote more rapid and more uniform cooking or baking, the apparatus including a motor, fan blade and housing of metallic materials selected from a class of heat resistant materials.

Jorgensen, Jorgen A. (Bloomington, MN); Nygren, Donald W. (Minneapolis, MN)

1983-01-01T23:59:59.000Z

452

Compressed Air System Optimization  

E-Print Network [OSTI]

Several years ago I went to a gas station and noticed that my car's tires were low on air. I saw the gas station had an air compressor, but it cost a quarter to use the compressor. I paid my quarter and used the compressor. I realized...

Aegerter, R.

453

Design of RF Conditioner Cavities  

E-Print Network [OSTI]

For most designs, the power loss at the cavity surface atheld fixed, the frequency, power loss and a more systematicwhile the cavity power loss (normalized by a factor of four

Govil, R.

2008-01-01T23:59:59.000Z

454

Conditioner for flotation of coal  

SciTech Connect (OSTI)

A method for recovering coal is described which comprises the steps of floating coal in an aqueous frothing medium containing an amount of a condensation product of an alkanolamine and naphthenic acid sufficient to increase the recovery of coal as compared to the recovery of coal in an identical process using none of the condensation product.

Nimerick, K.H.

1988-03-22T23:59:59.000Z

455

EA-1637: Finding of No Significant Impact  

Broader source: Energy.gov [DOE]

Energy Conservation Program for Commercial and Industrial Equipment: Packaged Terminal Air Conditioner and Packaged Terminal Heat Pump Energy Conservation Standards

456

Demand response enabling technology development  

E-Print Network [OSTI]

battery voltage. NOTE: This device does not control the thermoelectric air conditioner on the plastic model house.

2006-01-01T23:59:59.000Z

457

E-Print Network 3.0 - advanced heat process Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Heat Transfer Performance... ) Heat Transfer Solid Mechanics Energy Systems Air-Conditioner Performance Evaluations Alternate... and Diagnostic Center...

458

Energy for 500 Million Homes: Drivers and Outlook for Residential Energy Consumption in China  

E-Print Network [OSTI]

Heat Pump Air Conditioner District Heating Boiler Gas Boiler Electricity Figure 11 Space Heating Technology Shift in Residential

Zhou, Nan

2010-01-01T23:59:59.000Z

459

CX-001264: Categorical Exclusion Determination | Department of...  

Broader source: Energy.gov (indexed) [DOE]

including heating, ventilation, air conditioner upgrades, boiler replacement, heating pipe insulating, lighting replacements, main entry doors replacements, restroom motion...

460

E-Print Network 3.0 - aerodynamic heating Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

COLLEGE OF ENGINEERING Research Areas Summary: ) Heat Transfer Solid Mechanics Energy Systems Air-Conditioner Performance Evaluations Alternate... and Diagnostic...

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Considerations for Emerging Markets for Energy Savings Certificates  

E-Print Network [OSTI]

air conditioners; and insulation or other heating or cooling measures, such as HVAC system upgrades, ground source heat pumps,

Friedman, Barry

2009-01-01T23:59:59.000Z

462

Instrumented home energy rating and commissioning  

E-Print Network [OSTI]

air conditioner indicated that it is a 25 year old, low efficiency unit that is in need of replacement.

Wray, Craig P.; Walker, Iain S.; Sherman, Max H.

2003-01-01T23:59:59.000Z

463

Requirements Hydrocarbon  

E-Print Network [OSTI]

. He considered two coolants: Butane and R134a (freon replacement used in auto air conditioners). About

Cinabro, David

464

TRANSPORTATION SERVICES VEHICLE RENTAL FEES  

E-Print Network [OSTI]

ENVIRONMENT FEES AIR CONDITIONER SERVICE $75.00 PARTS + 10% BATTERY CHARGE $25.00 BATTERY REPLACEMENT $25

465

ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY  

E-Print Network [OSTI]

of the retrofitted case study house by adding envelope insulation, a more efficient furnace and air conditioner

466

Public Meeting: Physical Characterization of Grid-Connected Commercial...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

and Definitions; Characterization Protocol Framework; Illustrative Example: Room Air Conditioner (RAC); Process for Developing Characterization Protocols; Overview of...

467

August 2009 In this edition  

E-Print Network [OSTI]

, air conditioner registration, key returns at move-out, etc.) · Sign-up for various events and programs

Shyy, Wei

468

September 10, 2012 Key Centric Identity and  

E-Print Network [OSTI]

to read and set a home thermostat, air conditioner and appliance settings in a house. ­ The power company

469

50-Plus Ways to Be Water Smart 1. If your local water utility offers water-saving incentives or in-home water audits, take advantage  

E-Print Network [OSTI]

the dishwasher. Scrape dishes off rather than rinsing them off. 18. If you have an evaporative air conditioner

470

The minimum-uncertainty coherent states for Landau levels  

SciTech Connect (OSTI)

The Glauber minimum-uncertainty coherent states with two variables for Landau levels, based on the representation of Weyl-Heisenberg algebra by two different modes, have been studied about four decades ago. Here, we introduce new two-variable coherent states with minimum uncertainty relationship for Landau levels in three different methods: the infinite unitary representation of su(1, 1) is realized in two different methods, first, by consecutive levels with the same energy gaps and also with the same value for z-angular momentum quantum number, then, by shifting z-angular momentum mode number by two units while the energy level remaining the same. Besides, for su(2), whether by lowest Landau levels or Landau levels with lowest z-angular momentum, just one finite unitary representation is introduced. Having constructed the generalized Klauder-Perelomov coherent states, for any of the three representations, we obtain their Glauber coherency by displacement operator of Weyl-Heisenberg algebra.

Dehghani, A. [Physics Department, Payame Noor University, P. O. Box 19395-4697 Tehran (Iran, Islamic Republic of); Fakhri, H. [Department of Theoretical Physics and Astrophysics, Faculty of Physics, University of Tabriz, P. O. Box 51666-16471 Tabriz (Iran, Islamic Republic of); Mojaveri, B. [Department of Physics, Azarbaijan Shahid Madani University, P. O. Box 51745-406 Tabriz (Iran, Islamic Republic of)

2012-12-15T23:59:59.000Z

471

Investigation of a minimum energy Earth-Mars trajectory  

E-Print Network [OSTI]

INVESTIGATION OF A MINIMUM ENERGY EARTH-MARS TRAJECTORY A Thesis by Richard Emmett grown Submitted to the Graduate Co11ege of the Texas ASM University in partia1 fulfi11ment of the requirements for the degree of MASTER OF SCIENCE May 1967... Major Subject: Aerospace Engineering INVESTIGATION OF A MINIMIIM ENERGy EARTH MARS TRAJECTORy A Thesis by Richard Emmett Brown Approved as to style and content by; (Co-chairman of Committee) (Head of Department) (Member) May I967 TABLE...

Brown, Richard Emett

1967-01-01T23:59:59.000Z

472

The Energy-Dependence of GRB Minimum Variability Timescales  

E-Print Network [OSTI]

We constrain the minimum variability timescales for 938 GRBs observed by the Fermi/GBM instrument prior to July 11, 2012. The tightest constraints on progenitor radii derived from these timescales are obtained from light curves in the hardest energy channel. In the softer bands -- or from measurements of the same GRBs in the hard X-rays from Swift -- we show that variability timescales tend to be a factor 2--3 longer. Applying a survival analysis to account for detections and upper limits, we find median minimum timescale in the rest frame for long-duration and short-duration GRBs of 45 ms and 10 ms, respectively. Fewer than 10% of GRBs show evidence for variability on timescales below 2 ms. These shortest timescales require Lorentz factors $\\gtrsim 400$ and imply typical emission radii $R \\approx 1 {\\times} 10^{14}$ cm for long-duration GRBs and $R \\approx 3 {\\times} 10^{13}$ cm for short-duration GRBs. We discuss implications for the GRB fireball model and investigate whether GRB minimum timescales evolve w...

Golkhou, V Zach; Littlejohns, Owen M

2015-01-01T23:59:59.000Z

473

SOLAR ROTATION RATE DURING THE CYCLE 24 MINIMUM IN ACTIVITY  

SciTech Connect (OSTI)

The minimum of solar cycle 24 is significantly different from most other minima in terms of its duration as well as its abnormally low levels of activity. Using available helioseismic data that cover epochs from the minimum of cycle 23 to now, we study the differences in the nature of the solar rotation between the minima of cycles 23 and 24. We find that there are significant differences between the rotation rates during the two minima. There are differences in the zonal-flow pattern too. We find that the band of fast rotating region close to the equator bifurcated around 2005 and recombined by 2008. This behavior is different from that during the cycle 23 minimum. By autocorrelating the zonal-flow pattern with a time shift, we find that in terms of solar dynamics, solar cycle 23 lasted for a period of 11.7 years, consistent with the result of Howe et al. (2009). The autocorrelation coefficient also confirms that the zonal-flow pattern penetrates through the convection zone.

Antia, H. M. [Tata Institute of Fundamental Research, Homi Bhabha Road, Mumbai 400005 (India); Basu, Sarbani, E-mail: antia@tifr.res.i, E-mail: sarbani.basu@yale.ed [Department of Astronomy, Yale University, P.O. Box 208101, New Haven CT 06520-8101 (United States)

2010-09-01T23:59:59.000Z

474

Understanding the Dehumidification Performance of Air-Conditioning Equipment at Part-Load Conditions  

SciTech Connect (OSTI)

Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions--especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and may negatively impact indoor air quality. This report summarizes the results of a comprehensive project to better understand and quantify the moisture removal (dehumidification) performance of cooling coils at part-load conditions. A review of the open literature was initially conducted to learn from previous research on this topic. Detailed performance measurements were then collected for eight cooling coils in a controlled laboratory setting to understand the impact of coil geometry and operating conditions on transient moisture condensation and evaporation by the coils. Measurements of cooling coil dehumidification performance and space humidity levels were also collected at seven field test sites. Finally, an existing engineering model to predict dehumidification performance degradation for single-stage cooling equipment at part-load conditions (Henderson and Rengarajan 1996) was enhanced to include a broader range of fan control strategies and an improved theoretical basis for modeling off-cycle moisture evaporation from cooling coils. The improved model was validated with the laboratory measurements, and this report provides guidance for users regarding proper model inputs. The model is suitable for use in computerized calculation procedures such as hourly or sub-hourly building energy simulation programs (e.g., DOE's EnergyPlus building energy simulation program, http://www.energyplus.gov ).

Don B. Shirey III; Hugh I. Henderson Jr; Richard A. Raustad

2006-01-01T23:59:59.000Z

475

Air Pollution Control Regulations: No. 7 - Emission of Air Contaminant...  

Broader source: Energy.gov (indexed) [DOE]

with the enjoyment of life and property. The criteria for determining compliance is listed in the regulations, and is based on other air pollution and ambient air standards...

476

Air ejector augmented compressed air energy storage system  

DOE Patents [OSTI]

Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air pressure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

1980-01-01T23:59:59.000Z

477

Air Resources: Prevention and Control of Air Contamination and Air  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists' ResearchThe OfficeUtility Fed. GovernmentFed. Government CommercialPollution, Air

478

White Paper on Energy Efficiency Status of Energy-Using Products in China (2012)  

E-Print Network [OSTI]

of household air conditioning products. 1.2.2 IndustrialIn 2011, the room air conditioner products (not includingenergy efficient products in multi-split air conditioning (

Zhou, Nan

2013-01-01T23:59:59.000Z

479

Status of China's Energy Efficiency Standards and Labels for Appliances and International Collaboration  

E-Print Network [OSTI]

testing in 2006 for refrigerators, freezers and room air-three products (refrigerators, freezers, air-conditionersStandards Domestic refrigerators/freezers* Room air

Zhou, Nan

2010-01-01T23:59:59.000Z

480

2006 Status Report Savings Estimates for the ENERGY STAR(R) Voluntary Labeling Program  

E-Print Network [OSTI]

and Cooling - Furnace (Gas or Oil) - Central Air Conditioner - Air-Source Heat Pump - Geothermaland Cooling (HVAC). The HVAC program covers air-source heat pumps, geothermal

Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla; Homan, Gregory K.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "air conditioner minimum" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Analysis of Potential Energy Saving and CO2 Emission Reduction of Home Appliances and Commercial Equipments in China  

E-Print Network [OSTI]

Multi-connected air condition (heat pump) unit Chiller VL CRefrigerator Heat Pump Water Heater Air Conditioner ElectricHeat Pump Water Heater Standby TV Refrigerator Others* Air

Zhou, Nan

2011-01-01T23:59:59.000Z

482

Calendar Year 2008 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network [OSTI]

conditioning, ASHP = air source heat pump, HP = heat pump,Conditioners and Air-Source Heat Pumps • Commercial Fryers •Heating and Cooling -Air Source Heat Pump -Geothermal Heat

Homan, GregoryK

2010-01-01T23:59:59.000Z

483

Calendar Year 2009 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network [OSTI]

conditioning, ASHP = air source heat pump, HP = heat pump,Conditioners and Air-Source Heat Pumps • Commercial Fryers •Ovens -Griddles HVAC -Air Source Heat Pump -Geothermal Heat

Homan, Gregory K

2011-01-01T23:59:59.000Z

484

Commit to Efficiency Resource Kit  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Air Conditioners n * Chillers - Air-Cooled Electric p - Water-Cooled Electric p * Air Source Heat Pumps n Commercial Water Heating * Gas Water Heaters p Residential Space...

485

Utilities District of Western Indiana REMC- Residential Energy Efficiency Rebate Program  

Broader source: Energy.gov [DOE]

Utilities District of Western Indiana REMC offers residential customers incentives for energy efficient heat pumps, water heaters, and air conditioners. Eligible air-source heat pump and air...

486

Health Hazards in Indoor Air  

E-Print Network [OSTI]

Health Hazards in Indoor Air. In Proceedings of the 2010for VOCs from post-1990 indoor air concentration studies inUnion project on indoor air pollutants. Allergy, 2008. 63(

Logue, Jennifer M.

2012-01-01T23:59:59.000Z

487

Texas Clean Air Act (Texas)  

Broader source: Energy.gov [DOE]

This Act is designed to safeguard the state's air resources from pollution by requiring the control and abatement of air pollution and emissions of air contaminants, consistent with the protection...

488

Monitoring Software using Sun Spots Corey Andalora  

E-Print Network [OSTI]

that a user can use to view the current conditions of the air conditioners as well as historical data should be reported to the user. In addition, air conditioners should be on if the temperature of a room is above a certain threshold. If the air conditioner is not on but the temperature given by the sensor

Kaminsky, Alan

489

National Oceanic and Atmospheric Administration (NOAA) ExplorE thE EarthScience | Service | StewardshipScience | Service | Stewardship  

E-Print Network [OSTI]

that is about 2 inches to 4 inches high r A replaceable air conditioner filter large enough to cover the box r conditioner filter at 1/2-inch intervals as shown in the "Air Conditioner Filter Grid" drawing. Label cement to fasten small objects to the inside bottom of the cardboard box. 2. Mark the sides of the air

490

Math!. Comput. Modelling Vol. 23, No. 11/12, pp. 55-76. 1996 Copyright@1996 Elsevier Science Ltd  

E-Print Network [OSTI]

control system is the heating and cooling system of a typical home. The furnace and air conditioner, along and the thermostat's response is translated back to electrical currents which control the furnace, air conditioner that translate into commands to turn on or off the furnace or the air conditioner. This work was partially

Lemmon, Michael

491

Georgia Institute of Technology Environmental Health and Safety  

E-Print Network [OSTI]

? Battery is free of leaks? Back-up alarm works? Windshield washer fluid? Heating, Air Conditioner of leaks? Back-up alarm works? Windshield washer fluid? Heating, Air Conditioner and Defroster works? Battery is free of leaks? Back-up alarm works? Windshield washer fluid? Heating, Air Conditioner

492

Adaptive Reduction of Additive Noise From Sleep Breathing Sounds Tech Report: CSLU-2012-001  

E-Print Network [OSTI]

of a sound classification sys- tem. Air conditioners and furnaces are typical sources of this type of noise in a home environment. During the course of a single night, an air conditioner or furnace may turn to sudden changes in the background noise (e. g. an air conditioner turning on), as well as overall

Kain, Alexander

493

2102, Page 1 Experimental Investigation of Closed Loop Oscillating Heat Pipe as the  

E-Print Network [OSTI]

pipe (CLOHP) as the condenser for a vapor compression refrigeration system. Split type air conditioner condenser in the split type air conditioner. The refrigeration capacity was set at 12,500 Btu/h (3.663 k is commonly used in a wide range of residential and commercial buildings. Most of the air conditioner types

Ghajar, Afshin J.

494

1 Copyright 2007 by ASME Proceedings of IMECE 2007  

E-Print Network [OSTI]

EFFECTS ON AIR-CONDITIONER PERFORMANCE Matthew J. Sitzmann Haag Engineering, Co. 2455 McIver Lane.S.A. ssmith@haagengineering.com ABSTRACT Experiments demonstrated the effects on air-conditioner system-type air-conditioners were tested. Flattening substantial areas of the fins caused a reduc- tion

Texas at Arlington, University of

495

China Energy Efficiency Round Robin Testing Results for Room  

E-Print Network [OSTI]

LBNL-3502E China Energy Efficiency Round Robin Testing Results for Room Air Conditioners Nan Zhou Berkeley National Laboratory is an equal opportunity employer. #12;i Table of Contents I. Air Conditioner.......................................................................................................................... 6 I.2.1 Necessity for Air Conditioner Round Robin Testing

496

Acts of Commanding and Changing Obligations Tomoyuki Yamada  

E-Print Network [OSTI]

. There is a window and an air conditioner. You can open the window, or turn on the air conditioner. You can also does it affect the number of alternatives you have. It still is possible for you to turn on the air conditioner, to ignore the heat, or to open the window, of course. But it has now become impossible for you

Amsterdam, University of

497

Air heating system  

DOE Patents [OSTI]

A self-starting, fuel-fired, air heating system including a vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with the provision of heat exchanger and circuitry for cooling the condensed fluid output from the pump prior to its return to the vapor generator.

Primeau, John J. (19800 Seminole Rd., Euclid, OH 44117)

1983-03-01T23:59:59.000Z

498

Evaluation of the Indoor Air Quality Procedure for Use in Retail Buildings  

E-Print Network [OSTI]

, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service). The IAQP determines minimum VRs based on objectively and subjectively evaluated indoor air quality (IAQ

499

Regression analysis of residential air-conditioning energy consumption at Dhahran, Saudi Arabia  

SciTech Connect (OSTI)

The energy consumption of a house air conditioner located at Dhahran, Saudi Arabia, is modeled as a function of weather parameters and total (global) solar radiation on a horizontal surface. The selection of effective parameters that significantly influence energy consumption is carried out using general stepping regression methods. The problem of collinearity between the regressors is also investigated. The final model involves parameters of total solar radiation on a horizontal surface, wind speed, and temperature difference between the indoor and outdoor condition. However, the model coefficients are functions of relative humidity and/or temperature difference between the indoor and outdoor condition. Model adequacy is examined by the residual analysis technique. Model validation is carried out by the data-splitting technique. The sensitivity of the model indicates that relative humidity and temperature difference strongly influence the cooling energy consumption. It was found that an increase in relative humidity from 20% to 100% can cause a 100% increase in cooling energy consumption during the high cooling season.

Abdel-Nabi, D.Y.; Zubair, S.M.; Abdelrahman, M.A.; Bahel, V. (Energy Systems Group, Div. of Energy Resources, Research Inst., King Fahd Univ. of Petroleum and Minerals, Dhahran (SA))

1990-01-01T23:59:59.000Z

500

Ambient Air Quality Standards (Iowa)  

Broader source: Energy.gov [DOE]

These regulations set statewide ambient air quality standards for various contaminants. The state code follows the regulations set forth in the National Primary and Secondary Ambient Air Quality...