Powered by Deep Web Technologies
Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

--No Title--  

Gasoline and Diesel Fuel Update (EIA)

Central Air Condi- tioners Heat Pumps Indiv- idual Air Condi- tioners District Chilled Water Central Chillers Pack- aged Air Condi- tioning Units Swamp Coolers Other All...

2

Optimal Supply Angle of Upside Air Supply in Manned Spacecraft Cabin-Based Air Age  

E-Print Network [OSTI]

The age of air in the workaround of a manned spacecraft cabin that contain astronauts, apparatus and simple living establishments was numerically simulated by use of commercial software and a standard k-e turbulence model. An air inlet installed...

Liang, Z.; Zhang, J.; Lu, Y.

2006-01-01T23:59:59.000Z

3

Swedish industry is exposed to increasingly fierce competition. We need improved condi-  

E-Print Network [OSTI]

to medium sized companies as members. LiU is the largest contributor in this area in addition to basic edSwedish industry is exposed to increasingly fierce competition. We need improved condi- tions for robust domestic production. Effec- tive use of resources is necessary for sustain- able development. Li

Zhao, Yuxiao

4

Studies of asphalt air blowing and development of a new short-term aging technique  

E-Print Network [OSTI]

In this work asphalt air blowing has been studied from two perspectives. First, the process itself was investigated in terms of the effect of air-blowing conditions on the properties of the asphalt materials obtained. It was found that according...

Vassiliev, Nicolai

2001-01-01T23:59:59.000Z

5

Aging and service wear of air-operated valves used in safety-related systems at nuclear power plants  

SciTech Connect (OSTI)

Air-operated valves (AOVs) are used in a variety of safety-related applications at nuclear power plants. They are often used where rapid stroke times are required or precise control of the valve obturator is required. They can be designed to operate automatically upon loss of power, which is often desirable when selecting components for response to design basis conditions. The purpose of this report is to examine the reported failures of AOVs and determine whether there are identifiable trends in the failures related to predictable causes. This report examines the specific components that comprise a typical AOV, how those components fail, when they fail, and how such failures are discovered. It also examines whether current testing frequencies and methods are effective in predicting such failures.

Cox, D.F.; McElhaney, K.L.; Staunton, R.H.

1995-05-01T23:59:59.000Z

6

6. Environmental Context HERVE MARTIN  

E-Print Network [OSTI]

continuous, it was also a highly irregular process (Condie, 1989; McCulloch and Bennet, 1993; Condie, 1998Culloch and Bennet, 1993) and compilation of crustal zircon ages (Condie, 1989; Condie, 1998). It shows

Claeys, Philippe

7

Air Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Why Air Quality Air Quality To preserve our existing wilderness-area air quality, LANL implements a conscientious program of air monitoring. April 12, 2012 Real-time data...

8

CO2 isotopes as tracers of firn air diffusion and age in an Arctic ice cap with summer melting, Devon Island, Canada  

E-Print Network [OSTI]

and the effects of summer melting. The 14 CO2 profile from the permeable firn includes the 1963 thermonuclear peak, and accumulation rates were calibrated with the depth of the 1963 thermonuclear 3 H peak. The average ages for CO2 and the ice matrix. Calibrated with the 1963 peak for thermonuclear 14 CO2, a 21.2-year reaction halftime

Chappellaz, Jérôme

9

Incorporating Experience Curves in Appliance Standards Analysis  

E-Print Network [OSTI]

residential central air condi- tioners, central heat pumps, and furnaces, collectively referred to as heating,

Desroches, Louis-Benoit

2012-01-01T23:59:59.000Z

10

Sticking with air  

SciTech Connect (OSTI)

A decision to replace more than 300 aging damper actuators at Independence Plant in Newark, Arkensas forced Entergy to make a choice between pneumatic and electric actuator designs. The dampers route air flow through separate dedicated compartments to ensure proper firing of pulverised coal. The reasons that pneumatics was chosen are discussed in this article. 4 figs.

Coker, S.N. [Entergy (US). Independence Plant

2005-06-01T23:59:59.000Z

11

Aging gauge  

DOE Patents [OSTI]

An aging gauge comprising a container having a fixed or a variable sized t opening with a cap which can be opened to control the sublimation rate of a thermally sublimational material contained within the container. In use, the aging gauge is stored with an item to determine total heat the item is subjected to and also the maximum temperature to which the item has been exposed. The aging gauge container contains a thermally sublimational material such as naphthalene or similar material which has a low sublimation rate over the temperature range from about 70.degree. F. to about 160.degree. F. The aging products determined by analyses of a like item aged along with the aging gauge for which the sublimation amount is determined is employed to establish a calibration curve for future aging evaluation. The aging gauge is provided with a means for determining the maximum temperature exposure (i.e., a thermally indicating material which gives an irreversible color change, Thermocolor pigment). Because of the relationship of doubling reaction rates for increases of 10.degree. C., equivalency of item used in accelerated aging evaluation can be obtained by referring to a calibration curve depicting storage temperature on the abscissa scale and multiplier on the ordinate scale.

Betts, Robert E. (Huntsville, AL); Crawford, John F. (Huntsville, AL)

1989-01-01T23:59:59.000Z

12

Air Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc Documentation RUCProductstwrmrAre theAdministratorCFM LEAPAgendaConditioning AirWhy » Air

13

PROCEEDINGS OF 1976 SUMMER WORKSHOP ON AN ENERGY EXTENSION SERVICE  

E-Print Network [OSTI]

industrial plants with large service or domestic hot water requirements,coupled with large air condi- tioning or heat pump

Authors, Various

2010-01-01T23:59:59.000Z

14

Air Quality: Construction Project Air Permit Requirements  

E-Print Network [OSTI]

Air Quality: Construction Project Air Permit Requirements Department: Chemical and General Safety Program: Air Quality Owner: Program Manager Authority: ES&H Manual, Chapter 30, Air Quality1 All manager or operator must submit the completed form to the air quality program manager before the project

Wechsler, Risa H.

15

Energy-efficiency labels and standards: A guidebook for appliances, equipment and lighting  

E-Print Network [OSTI]

commercial-package air-conditioning and heating equipment, packaged terminal air condi- tioners and heat pumps, warm-air furnaces, packaged boilers, storage water heaters,

McMahon, James E.; Wiel, Stephen

2001-01-01T23:59:59.000Z

16

Metal-Air Batteries  

SciTech Connect (OSTI)

Metal-air batteries have much higher specific energies than most currently available primary and rechargeable batteries. Recent advances in electrode materials and electrolytes, as well as new designs on metal-air batteries, have attracted intensive effort in recent years, especially in the development of lithium-air batteries. The general principle in metal-air batteries will be reviewed in this chapter. The materials, preparation methods, and performances of metal-air batteries will be discussed. Two main metal-air batteries, Zn-air and Li-air batteries will be discussed in detail. Other type of metal-air batteries will also be described.

Zhang, Jiguang; Bruce, Peter G.; Zhang, Gregory

2011-08-01T23:59:59.000Z

17

Air temperature thresholds for indoor comfort and perceived air quality  

E-Print Network [OSTI]

in the Netherlands, Indoor Air 2, 127 136. BuildingPaliaga, G. (2009) Moving air for comfort. ASHRAE Journal,ventilation system on perceived air quality, Indoor Air

Zhang, Hui; Edward, Arens; Pasut, Wilmer

2012-01-01T23:59:59.000Z

18

Moving air for comfort  

E-Print Network [OSTI]

Brager, L. Zagreus. 2007, Air movement preferences observed709-731. 9. Toftum, J. 2004. Air movement good or bad? Indoor Air 14, pp 40-45. 10. Gong, N. , K. Tham, A. Melikov,

Arens, Edward; Turner, Stephen; Zhang, Hui; Paliaga, Gwelen

2009-01-01T23:59:59.000Z

19

Feasibility of air capture  

E-Print Network [OSTI]

Capturing CO2 from air, referred to as Air Capture, is being proposed as a viable climate change mitigation technology. The two major benefits of air capture, reported in literature, are that it allows us to reduce the ...

Ranjan, Manya

2010-01-01T23:59:59.000Z

20

Primary zone air proportioner  

DOE Patents [OSTI]

An air proportioner is provided for a liquid hydrocarbon fueled gas turbine of the type which is convertible to oil gas fuel and to coal gas fuel. The turbine includes a shell for enclosing the turbine, an air duct for venting air in said shell to a gasifier, and a fuel injector for injecting gasified fuel into the turbine. The air proportioner comprises a second air duct for venting air from the air duct for mixing with fuel from the gasifier. The air can be directly injected into the gas combustion basket along with the fuel from the injector or premixed with fuel from the gasifier prior to injection by the fuel injector.

Cleary, Edward N. G. (San Diego, CA)

1982-10-12T23:59:59.000Z

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Air Tightness of US Homes: Model Development  

SciTech Connect (OSTI)

Air tightness is an important property of building envelopes. It is a key factor in determining infiltration and related wall-performance properties such as indoor air quality, maintainability and moisture balance. Air leakage in U.S. houses consumes roughly 1/3 of the HVAC energy but provides most of the ventilation used to control IAQ. The Lawrence Berkeley National Laboratory has been gathering residential air leakage data from many sources and now has a database of more than 100,000 raw measurements. This paper uses that database to develop a model for estimating air leakage as a function of climate, building age, floor area, building height, floor type, energy-efficiency and low-income designations. The model developed can be used to estimate the leakage distribution of populations of houses.

Sherman, Max H.

2006-05-01T23:59:59.000Z

22

AiR surface: AiR surface 1  

E-Print Network [OSTI]

AiR surface: 1 PDA AiR surface 1 1: AiR surface () () 2 [1] [2] 3 AiR surface AiR surface surface surface surface 3.1 surface [3]( 3 ) surface 3.2 surface surface AiR surface 4 AiR surface surface AiR surface: Virtual Touch Panel

Tanaka, Jiro

23

Air Pollution Spring 2010  

E-Print Network [OSTI]

ATS 555 Air Pollution Spring 2010 T Th 11:00 ­ 12:15, NESB 101 Instructor: Prof. Sonia Kreidenweis an understanding of types and sources of air pollution. 2. Examine concentrations of air pollutants and their effects on health and welfare. Review regulations governing air pollution. 3. Examine the meteorological

24

Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature?  

E-Print Network [OSTI]

The supply air temperature set point for a singleduct constant air volume air handling unit (AHU) system is often reset based on either return air temperature or outside air temperature in order to reduce simultaneous cooling and heating energy...

Wei, G.; Turner, W. D.; Claridge, D.; Liu, M.

2002-01-01T23:59:59.000Z

25

7, 1365313697, 2007 Global mean age of  

E-Print Network [OSTI]

ACPD 7, 13653­13697, 2007 Global mean age of air from MIPAS G. P. Stiller et al. Title Page measurements G. P. Stiller 1 , T. von Clarmann 1 , M. H¨opfner 1 , N. Glatthor 1 , U. Grabowski 1 , S. Kellmann Correspondence to: G. P. Stiller (gabriele.stiller@imk.fzk.de) 13653 #12;ACPD 7, 13653­13697, 2007 Global mean

Paris-Sud XI, Université de

26

Aesculap, Inc. Air Products  

E-Print Network [OSTI]

Aesculap, Inc. Air Products Air Products Foundation Alaric Compliance Services, LLC Alvin H. Butz & Herger, Inc. Sodexo Campus Services Sodexo Inc. and Affiliates Stupp Bros., Inc. Sugarbush Products, Inc

Napier, Terrence

27

General Air Permits (Louisiana)  

Broader source: Energy.gov [DOE]

Any source, including a temporary source, which emits or has the potential to emit any air contaminant requires an air permit. Facilities with potential emissions less than 5 tons per year of any...

28

Healthy Air Act (Maryland)  

Broader source: Energy.gov [DOE]

The Maryland Healthy Air Act was developed with the purpose of bringing Maryland into attainment with the National Ambient Air Quality Standards (NAAQS) for ozone and fine particulate matter by the...

29

on man, nature & air pollution  

E-Print Network [OSTI]

on man, nature & air pollution About three decades ago, itand episodes of air pollution the following summer. Wetthe increase in air pollution. This hypothesis generated

Finlayson-Pitts, Barbara J

2008-01-01T23:59:59.000Z

30

Air Products effective way  

E-Print Network [OSTI]

PE O A e s a b O T A O ENNST Overview Air Products effective way standard me Departm Shipping has recently y of shipping eans. Air Pro ontainer that es of this pro onduct mark eep accelera eep the cost tilize widely a earch and m m visited Air er needs wer model was cr m approache ms

Demirel, Melik C.

31

Air Quality Chapter Outline  

E-Print Network [OSTI]

Chapter 30 Air Quality Chapter Outline 1 Overview 2 1.1 Hazards / Impacts 2 1.2 Exposure Sources 3 Manual Chapter 30: Air Quality 7 References 20 8 Implementation 21 9 Ownership 22 1 Overview SLAC operations produce a wide range of air emissions. Sources of emissions include standard equipment

Wechsler, Risa H.

32

MAD-AIR  

E-Print Network [OSTI]

with stress- related illness rather than the anwr that spells RELIEF. Air flow in, through ad arourd a house is an important concern in the building we call haw. !lb enhance air flow and change the various corditions or properties of the air, a variety...

Tooley, J. J.; Moyer, N. A.

1989-01-01T23:59:59.000Z

33

Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles  

E-Print Network [OSTI]

temperature at supply air temperature setpoint. Mechanical cooling is always required when outside air temperature is higher than the supply air temperature setpoint. Generally the supply air temperature setpoint is set at 55F for space humidity control...

Xu, K.; Liu, M.; Wang, G.; Wang, Z.

2007-01-01T23:59:59.000Z

34

Air to Air Communication Protocol Arjan Durresi1  

E-Print Network [OSTI]

1 Air to Air Communication Protocol Arjan Durresi1 , Vamsi Paruchuri1 , Leonard Barolli2 and Raj. Louis, MO 63130, USA 314-935-4963, jain@cse.wustl.edu Abstract--We present Air to Air Communication (AAC........................................................2 3. AIR TO AIR COMMUNICATION..............................3 4. SIMULATIONS

Jain, Raj

35

ORIGINAL ARTICLE Ambient Air Pollution  

E-Print Network [OSTI]

ORIGINAL ARTICLE Ambient Air Pollution and Cardiovascular Emergency Department Visits Kristi Busico ambient air pollutants and cardiovascular disease (CVD), the roles of the physicochemical components the relation between ambient air pollution and cardiovascular conditions using ambient air quality data

Mulholland, James A.

36

Personal continuous air monitor  

DOE Patents [OSTI]

A personal continuous air monitor capable of giving immediate warning of the presence of radioactivity has a filter/detector head to be worn in the breathing zone of a user, containing a filter mounted adjacent to radiation detectors, and a preamplifier. The filter/detector head is connected to a belt pack to be worn at the waist or on the back of a user. The belt pack contains a signal processor, batteries, a multichannel analyzer, a logic circuit, and an alarm. An air pump also is provided in the belt pack for pulling air through the filter/detector head by way of an air tube.

Morgan, Ronald G. (Los Alamos, NM); Salazar, Samuel A. (Albuquerque, NM)

2000-01-01T23:59:59.000Z

37

Environmental Quality: Air (Louisiana)  

Broader source: Energy.gov [DOE]

The Department of Environmental Quality regulates air quality in Louisiana. The Department has an established a fee system for funding the monitoring, investigation and other activities required...

38

International MODIS and AIRS processing package: AIRS products and applications  

E-Print Network [OSTI]

International MODIS and AIRS processing package: AIRS products and applications Elisabeth Weisz presented and discussed in this paper demonstrate that the IMAPP AIRS retrieval product is rigorously parameters from the operational AIRS L2 product and data from other instruments. Keywords: AIRS, IMAPP

Li, Jun

39

AIR SEALING Seal air leaks and save energy!  

E-Print Network [OSTI]

AIR SEALING Seal air leaks and save energy! W H A T I S A I R L E A K A G E ? Ventilation is fresh air that enters a house in a controlled manner to exhaust excess moisture and reduce odors and stuffiness. Air leakage, or infiltration, is outside air that enters a house uncontrollably through cracks

Oak Ridge National Laboratory

40

Recirculating electric air filter  

DOE Patents [OSTI]

An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

Bergman, W.

1985-01-09T23:59:59.000Z

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Portable oven air circulator  

DOE Patents [OSTI]

A portable air circulating apparatus for use in cooking ovens which is used to create air currents in the oven which transfer heat to cooking foodstuffs to promote more rapid and more uniform cooking or baking, the apparatus including a motor, fan blade and housing of metallic materials selected from a class of heat resistant materials.

Jorgensen, Jorgen A. (Bloomington, MN); Nygren, Donald W. (Minneapolis, MN)

1983-01-01T23:59:59.000Z

42

Compressed Air System Optimization  

E-Print Network [OSTI]

Several years ago I went to a gas station and noticed that my car's tires were low on air. I saw the gas station had an air compressor, but it cost a quarter to use the compressor. I paid my quarter and used the compressor. I realized...

Aegerter, R.

43

Air Pollution Control Regulations: No. 7 - Emission of Air Contaminant...  

Broader source: Energy.gov (indexed) [DOE]

with the enjoyment of life and property. The criteria for determining compliance is listed in the regulations, and is based on other air pollution and ambient air standards...

44

Air ejector augmented compressed air energy storage system  

DOE Patents [OSTI]

Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air pressure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

1980-01-01T23:59:59.000Z

45

Air Resources: Prevention and Control of Air Contamination and Air  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists' ResearchThe OfficeUtility Fed. GovernmentFed. Government CommercialPollution, Air

46

Health Hazards in Indoor Air  

E-Print Network [OSTI]

Health Hazards in Indoor Air. In Proceedings of the 2010for VOCs from post-1990 indoor air concentration studies inUnion project on indoor air pollutants. Allergy, 2008. 63(

Logue, Jennifer M.

2012-01-01T23:59:59.000Z

47

Texas Clean Air Act (Texas)  

Broader source: Energy.gov [DOE]

This Act is designed to safeguard the state's air resources from pollution by requiring the control and abatement of air pollution and emissions of air contaminants, consistent with the protection...

48

Air heating system  

DOE Patents [OSTI]

A self-starting, fuel-fired, air heating system including a vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with the provision of heat exchanger and circuitry for cooling the condensed fluid output from the pump prior to its return to the vapor generator.

Primeau, John J. (19800 Seminole Rd., Euclid, OH 44117)

1983-03-01T23:59:59.000Z

49

Ambient Air Quality Standards (Iowa)  

Broader source: Energy.gov [DOE]

These regulations set statewide ambient air quality standards for various contaminants. The state code follows the regulations set forth in the National Primary and Secondary Ambient Air Quality...

50

Retrofit Air Preheat Economics  

E-Print Network [OSTI]

Retrofit air preheat systems are the most reliable and efficient means to effect significant energy conservation for large existing industrial furnaces. Units can be quickly installed without a lengthy shutdown, and the furnace efficiency can...

Goolsbee, J. A.

1981-01-01T23:59:59.000Z

51

Breathing zone air sampler  

SciTech Connect (OSTI)

A sampling apparatus is provided which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.

Tobin, John (Bethel Park, PA)

1989-01-01T23:59:59.000Z

52

Breathing zone air sampler  

SciTech Connect (OSTI)

A sampling apparatus is presented which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.

Tobin, J.

1989-08-22T23:59:59.000Z

53

Padding with Compressed Air  

E-Print Network [OSTI]

We commonly find plants using padding to transport liquids or light solids short distances from tankers into storage tanks. Padding can wreck havoc in compressed air systems with limited storage, undersized cleanup equipment (dryers and filters...

Beals, C.

2004-01-01T23:59:59.000Z

54

Air Carrier Flight Operations  

E-Print Network [OSTI]

Most air carriers operate under a system of prioritized goals including safety, customer service (on-time departures and arrivals) and operating economics. The flight operations department is responsible for the safe and ...

Midkif, Alan H.

55

Air conditioning system  

DOE Patents [OSTI]

An air conditioner comprises a plurality of plates arranged in a successively stacked configuration with portions thereof having a spaced apart arrangement, and defining between successive adjacent pairs of plates at the spaced apart portions a first and second series of discrete alternating passages wherein a first air stream is passed through the first series of passages and a second air stream is passed through the second series of passages; and said stacked configuration of plates forming integrally therewith a liquid delivery means for delivering from a source a sufficient quantity of a liquid to the inside surfaces of the first series of fluid passages in a manner which provides a continuous flow of the liquid from a first end to a second end of the plurality of plates while in contact with the first air stream.

Lowenstein, Andrew; Miller, Jeffrey; Gruendeman, Peter; DaSilva, Michael

2005-02-01T23:59:59.000Z

56

Canned Air in China  

E-Print Network [OSTI]

Broadcast Transcript: Not that long ago, coal smoke made the air here in Beijing so caustic that your nasal passages were seared with each breath. Those were the good old days: Car ownership was limited to government ...

Hacker, Randi

2013-10-23T23:59:59.000Z

57

Air bag restraint device  

DOE Patents [OSTI]

A rear-seat air bag restraint device is disclosed that prevents an individual, or individuals, from continuing violent actions while being transported in a patrol vehicle`s rear seat without requiring immediate physical contact by the law enforcement officer. The air bag is activated by a control switch in the front seat and inflates to independently restrict the amount of physical activity occurring in the rear seat of the vehicle while allowing the officer to safely stop the vehicle. The air bag can also provide the officer additional time to get backup personnel to aid him if the situation warrants it. The bag is inflated and maintains a constant pressure by an air pump. 8 figs.

Marts, D.J.; Richardson, J.G.

1995-10-17T23:59:59.000Z

58

Combustion Air Control  

E-Print Network [OSTI]

calibration and tune-up: ? A measure of combustion efficiency must be selected as a target operating goal for the combustion control system. Possible measures and typical targets include: Stack Gas Excess Air, 15% Stack Gas Opacity, 0.3 RN Stack Gas CO... Fuel Flows ? Preheater Inlet Temperature ? Btu Flow (Fuel Flow ? Preheater Outlet Temperature Controller Measurement) ? Ambient Temperature ? Oxygen in the Stack ? Boiler Master Controller Output ? Opac i ty Normalize the steam, air and fuel flow...

Hughart, C. L.

1979-01-01T23:59:59.000Z

59

Clearing the Air: "AIR" Training Session Wednesday, December 18  

E-Print Network [OSTI]

Clearing the Air: "AIR" Training Session Wednesday, December 18 12 p.m. ­ 1:00 p.m. Human Resources/Tobacco- Free! Join us for an interactive session and learn more about "AIR" (Approach, Inform, Refer, and safe campus environment. Visit Clearing the Air website (http://tobaccofree.ucr.edu/) for more

Reed, Christopher A.

60

Air distribution effectiveness with stratified air distribution systems  

E-Print Network [OSTI]

1 Air distribution effectiveness with stratified air distribution systems Kisup Lee* Zheng Jiang, Ph.D Qingyan Chen, Ph.D. Student Member ASHRAE Fellow ASHRAE ABSTRACT Stratified air distribution systems such as Traditional Displacement Ventilation (TDV) and Under- Floor Air Distribution (UFAD

Chen, Qingyan "Yan"

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

inAir: Sharing Indoor Air Quality Measurements and Visualizations  

E-Print Network [OSTI]

evidence has indicated that indoor air pollution within homes and other buildings can be worse than the outdoor air pollution in even the largest and most industrialized cities. For example, the California Air Resources Board estimates that indoor air pollutant levels are 25-62% greater than outside levels [4

Mankoff, Jennifer

62

Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference  

E-Print Network [OSTI]

permit regulations are designed to track, record, and control air pollutants belonging to severalAir Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference Department: Chemical on chemical classifications. This reference outlines major categories of air pollutants found at SLAC

Wechsler, Risa H.

63

PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED INTO A DWELLING  

E-Print Network [OSTI]

PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED.peuportier@mines-paristech.fr, Tel.: +33 1 40 51 91 51 ABSTRACT An inverter-driven air-to-air heat pump model has been developped capacity air-to-air heat pump coupled with temperate air sources (crawlspace, attic, sunspace, heat

Paris-Sud XI, Université de

64

Air PSE (Problem Solving Environment)  

E-Print Network [OSTI]

PSE - 1 Air PSE (Problem Solving Environment) MODELLING OF AIR POLLUTION IN THE LOS ANGELES BASIN WITH AIR PSE Developed by Prof. Donald Dabdub Computational Environmental Sciences Laboratory Mechanical COMPUTER MODELS An air pollution model is a computer program that computes how the different chemical

Nizkorodov, Sergey

65

EMISSIONS TO AIR OPERATIONAL PROCEDURE  

E-Print Network [OSTI]

EMISSIONS TO AIR OPERATIONAL PROCEDURE Swansea University Estates Services Singleton Park Swansea to Air Department: Estates and Facilities Site: All Author: Ambreen Jahangir Approved by: Mark Durdin PURPOSE: To minimise emissions and discharges to air from boilers, fume cupboards, air conditioning

Harman, Neal.A.

66

Compressed air energy storage system  

DOE Patents [OSTI]

An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

1981-01-01T23:59:59.000Z

67

Command in air war : centralized vs. decentralized control of combat airpower  

E-Print Network [OSTI]

This study answers the question, "What has been the impact of the Information Age on the Air Force's doctrinal tenet of "centralized control and decentralized execution?" It traces the evolution of command and control of ...

Kometer, Michael W

2005-01-01T23:59:59.000Z

68

Ventilation Air Preconditioning Systems  

E-Print Network [OSTI]

capacity. Optional Morning Warm-up If connected to a liquid condenser bundle, the icemaking chiller can serve as a heat recovery heat pump. The chiller can freeze ice in the early morning to provide heat for morning warm-up, and use the ice... the cooling coil or drain pan re-evaporates and is delivered to occupied space during compressor off-cycles. Although heat recovery between the exhaust air and ventilation air can reduce the impact on the HVAC system, many buildings do not have central...

Khattar, M.; Brandemuehl, M. J.

1996-01-01T23:59:59.000Z

69

Parylene C Aging Studies.  

SciTech Connect (OSTI)

Parylene C is used in a device because of its conformable deposition and other advantages. Techniques to study Parylene C aging were developed, and %22lessons learned%22 that could be utilized for future studies are the result of this initial study. Differential Scanning Calorimetry yielded temperature ranges for Parylene C aging as well as post-deposition treatment. Post-deposition techniques are suggested to improve Parylene C performance. Sample preparation was critical to aging regimen. Short-term (~40 days) aging experiments with free standing and ceramic-supported Parylene C films highlighted %22lessons learned%22 which stressed further investigations in order to refine sample preparation (film thickness, single sided uniform coating, machine versus laser cutting, annealing time, temperature) and testing issues (%22necking%22) for robust accelerated aging of Parylene C.

Achyuthan, Komandoor; Sawyer, Patricia Sue.; Mata, Guillermo Adrian; White II, Gregory Von; Bernstein, Robert

2014-09-01T23:59:59.000Z

70

COOEE bitumen: chemical aging  

E-Print Network [OSTI]

We study chemical aging in "COOEE bitumen" using molecular dynamic simulations. The model bitumen is composed of four realistic molecule types: saturated hydrocarbon, resinous oil, resin, and asphaltene. The aging reaction is modelled by the chemical reaction: "2 resins $\\rightarrow$ 1 asphaltene". Molecular dynamic simulations of four bitumen compositions, obtained by a repeated application of the aging reaction, are performed. The stress autocorrelation function, the fluid structure, the rotational dynamics of the plane aromatic molecules, and the diffusivity of each molecule, are determined for the four different compositions. The aging reaction causes a significant dynamics slowdown, which is correlated to the aggregation of asphaltene molecules in larger and dynamically slower nanoaggregates. Finally, a detailed description of the role of each molecule types in the aggregation and aging processes is given.

Lemarchand, Claire A; Dyre, Jeppe C; Hansen, Jesper S

2013-01-01T23:59:59.000Z

71

E-Print Network 3.0 - air surveillance air Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Sample search results for: air surveillance air Page: << < 1 2 3 4 5 > >> 1 Public Health Air Surveillance Evaluation Project Public Health Air Surveillance Evaluation (PHASE)...

72

Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics  

E-Print Network [OSTI]

Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

Graham, E. L.

1980-01-01T23:59:59.000Z

73

Vermont Air Pollution Control Regulations, Ambient Air Quality Standards (Vermont)  

Broader source: Energy.gov [DOE]

The ambient air quality standards are based on the national ambient air quality standards. The Vermont standards are classified as primary and secondary standards and judged adequate to protect...

74

Environmental Pollution Air Pollution Dispersion Practical Air Pollution Dispersion  

E-Print Network [OSTI]

Environmental Pollution Air Pollution Dispersion 1 of 5 Practical ­ Air Pollution Dispersion in the lectures how such models can be used to explain observed concentrations of air pollutants in an area and to test `what-if' scenarios for pollution control and reduction. You will use the Gaussian Plume Model

Moncrieff, John B.

75

Tennessee Air Quality Act (Tennessee)  

Broader source: Energy.gov [DOE]

The Tennessee Air Quality Act (AQA) delegates the power to maintain air quality in the State to the Department of Environment and Conservation. Under the Department of the Environment and...

76

Fundamentals of Compressed Air Systems  

Broader source: Energy.gov [DOE]

Find out how a compressed air system works and the benefits of optimal compressed air system performance. This initial class demonstrates how to compute the current cost of your plant's compressed...

77

Louisiana Air Control Law (Louisiana)  

Broader source: Energy.gov [DOE]

This law states regulations for air quality control and states the powers and duties of the secretary of environmental quality. It provides information about permits and licenses, air quality...

78

Iodine Loading of NO Aged Silver Exchanged Mordenite  

SciTech Connect (OSTI)

In an off-gas treatment system for used nuclear fuel processing, a solid sorbent will typically be exposed to a gas stream for months at a time. This gas stream may be at elevated temperature and could contain water vapor, gaseous nitrogen oxides (NO{sub x}), nitric acid vapors, and a variety of other constituents. For this reason, it is important to evaluate the effects of long-term exposure, or aging, on proposed sorbents. Silver exchanged mordenite (AgZ) is being studied at Oak Ridge National Laboratory (ORNL) to determine its iodine sorption capacity after long term exposure to increasingly more complex chemical environments. Studies previously conducted at ORNL investigated the effects of aging reduced silver exchanged mordenite (Ag{sup 0}Z) in dry air, moist air, and NO2. This study investigated the effects of extended exposure to nitric oxide (NO) gas on the iodine capture performance of Ag{sup 0}Z. A deep bed of Ag{sup 0}Z was aged in a 1% nitric oxide (NO) air stream, and portions of the bed were removed at pre-determined intervals. After being removed from the NO stream, each sample was loaded with iodine in a thin bed configuration. These samples were analyzed by neutron activation analysis (NAA) to quantify the iodine content in the sample. Samples were removed at one week and one month. A 78% decrease in sample capacity was seen after one week of exposure, with no further decrease observed after 1 month of aging. The observed loss in capacity is larger in magnitude than previous studies exposing Ag{sup 0}Z to dry air, moist air, or NO2 gas. The aging study was terminated after one month and repeated; this successfully demonstrated the reproducibility of the results.

Patton, K. K. [ORNL; Bruffey, S. H. [ORNL; Jubin, J. T. [ORNL; Walker, Jr., J. F. [ORNL

2014-09-30T23:59:59.000Z

79

Compressed Air Energy Storage System  

E-Print Network [OSTI]

/expanders are crucial for the economical viability of a Compressed Air Energy Storage (CAES) system such as the

Farzad A. Shirazi; Mohsen Saadat; Bo Yan; Perry Y. Li; Terry W. Simon

80

Metal-air battery assessment  

SciTech Connect (OSTI)

The objective of this report is to evaluate the present technical status of the zinc-air, aluminum/air and iron/air batteries and assess their potential for use in an electric vehicle. In addition, this report will outline proposed research and development priorities for the successful development of metal-air batteries for electric vehicle application. 39 refs., 25 figs., 11 tabs.

Sen, R.K.; Van Voorhees, S.L.; Ferrel, T.

1988-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Making Compressed Air System Decisions  

E-Print Network [OSTI]

spawned an entire industry dedicated to manufacturing equipment designed to remove moisture, lubricant, particulate and vapor contaminants from compressed air. Purification equipment, such as air dryers and filters, are used alone or in combination... to reduce the amount of contaminants in the compressed air to the desired purity. All compressed ESL-IE-96-04-32 Proceedings from the Eighteenth Industrial Energy Technology Conference, Houston, TX, April 17-18, 1996 air purification equipment requires...

Porri, R. E.

82

Oil and Gas Air Heaters  

E-Print Network [OSTI]

, the relation of hot-air temperature, oil or gas consumption and fresh airflow is determined based on energy equilibrium....

Kou, G.; Wang, H.; Zhou, J.

2006-01-01T23:59:59.000Z

83

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers  

SciTech Connect (OSTI)

There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: closed and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percent age of the recirculation air is make-up air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both closed and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups: (1) Outside - coupons sheltered, located near or at the supply air inlet, but located before any filtering, (2) Supply - starting just after initial air filtering continuing inside the plenums and ducts feeding the data center rooms, and (3) Inside located inside the data center rooms near the IT equipment. Each coupon was exposed for thirty days and then sent to a laboratory for a corrosion rate measurement analysis. The goal of this research was to investigate whether gaseous contamination is a concern for U.S. data center operators as it relates to the reliability of IT equipment. More specifically, should there be an increased concern if outside air for IT equipment cooling is used To begin to answer this question limited exploratory measurements of corrosion rates in operating data centers in various locations were undertaken. This study sought to answer the following questions: (1) What is the precision of the measurements (2) What are the approximate statistical distributions of copper and silver corrosion rates in the sampled data centers(3) To what extent are copper and silver corrosion measurements related (4) What is the relationship of corrosion rate measurements between outside-air cooled data centers compared to closed data centers (5) How do corrosivity measurements relate to IT equipment failure rates The data from our limited sample size suggests that most United States data center operators should not be concerned with environmental gaseous contamination causing high IT equipment failure rates even when using outside-air cooling. The research team recommends additional basic research on how environmental conditions, specifically gaseous contamination, affect electronic equipment reliability.

Coles, Henry C.; Han, Taewon; Price, Phillip N.; Gadgil, Ashok J.; Tschudi, William F.

2011-07-17T23:59:59.000Z

84

COMBUSTION-GENERATED INDOOR AIR POLLUTION  

E-Print Network [OSTI]

The Japanese Union of Air Pollution Prevention Associations,The Status of Indoor Air Pollution Research 1976, GeometAnnual Meeting of the Air Pollution Control Association,

Hollowell, C.D.

2011-01-01T23:59:59.000Z

85

Review: Integrating Climate, Energy and Air Pollution  

E-Print Network [OSTI]

Climate, Energy and Air Pollution By Gary Bryner with RobertEnergy, and Air Pollution. Cambridge, Massachusetts, The MITClimate, Energy, and Air Pollution provides a well-

Toohey, David E.

2013-01-01T23:59:59.000Z

86

Radionuclide Air Emission Report for 2011  

E-Print Network [OSTI]

LBNL-470E-201 Radionuclide Air Emission Report for Preparedfor Estimating Fugitive Air Emissions of Radionuclides fromStandards for Hazardous Air Pollutants (Radionuclides),

Wahl, Linnea

2012-01-01T23:59:59.000Z

87

Air Pollution & Health in Rapidly Developing Countries  

E-Print Network [OSTI]

For example, Air Pollution and Health Studies in theAssessment of Air Pollution and Health is illustrative inReview: Air Pollution & Health in Rapidly Developing

Bucher, Scott

2005-01-01T23:59:59.000Z

88

FLUIDIC: Metal Air Recharged  

ScienceCinema (OSTI)

Fluidic, with the help of ARPA-E funding, has developed and deployed the world's first proven high cycle life metal air battery. Metal air technology, often used in smaller scale devices like hearing aids, has the lowest cost per electron of any rechargeable battery storage in existence. Deploying these batteries for grid reliability is competitive with pumped hydro installations while having the advantages of a small footprint. Fluidic's battery technology allows utilities and other end users to store intermittent energy generated from solar and wind, as well as maintain reliable electrical delivery during power outages. The batteries are manufactured in the US and currently deployed to customers in emerging markets for cell tower reliability. As they continue to add customers, they've gained experience and real world data that will soon be leveraged for US grid reliability.

Friesen, Cody

2014-04-02T23:59:59.000Z

89

Air Observe System  

E-Print Network [OSTI]

This manuscript contains a description and basic principles for observing inaccessible areas using low cost, easily deployed equipment. The basic premise is to suspend a tiny video camera at an altitude of 10 - 200 meters over the area to be surveyed. The TV camera supports at altitude by wind or balloon. The technical challenges regard the means by which the camera is suspended. Such a system may be used by military or police forces or by civil authorities for rescue missions or assessment of natural disasters. The method may be further developed for military applications by integrating the surveillance task with deployment of munitions. Key words: air observer, air suspended system, low altitude video observer.

Alexander Bolonkin

2007-01-10T23:59:59.000Z

90

FLUIDIC: Metal Air Recharged  

SciTech Connect (OSTI)

Fluidic, with the help of ARPA-E funding, has developed and deployed the world's first proven high cycle life metal air battery. Metal air technology, often used in smaller scale devices like hearing aids, has the lowest cost per electron of any rechargeable battery storage in existence. Deploying these batteries for grid reliability is competitive with pumped hydro installations while having the advantages of a small footprint. Fluidic's battery technology allows utilities and other end users to store intermittent energy generated from solar and wind, as well as maintain reliable electrical delivery during power outages. The batteries are manufactured in the US and currently deployed to customers in emerging markets for cell tower reliability. As they continue to add customers, they've gained experience and real world data that will soon be leveraged for US grid reliability.

Friesen, Cody

2014-03-07T23:59:59.000Z

91

Air cathode structure manufacture  

DOE Patents [OSTI]

An improved air cathode structure for use in primary batteries and the like. The cathode structure includes a matrix active layer, a current collector grid on one face of the matrix active layer, and a porous, nonelectrically conductive separator on the opposite face of the matrix active layer, the collector grid and separator being permanently bonded to the matrix active layer. The separator has a preselected porosity providing low IR losses and high resistance to air flow through the matrix active layer to maintain high bubble pressure during operation of the battery. In the illustrated embodiment, the separator was formed of porous polypropylene. A thin hydrophobic film is provided, in the preferred embodiment, on the current collecting metal grid.

Momyer, William R. (Palo Alto, CA); Littauer, Ernest L. (Los Altos Hills, CA)

1985-01-01T23:59:59.000Z

92

Air Pollution Socio-Economic  

E-Print Network [OSTI]

Traffic Air Pollution and Socio-Economic Status Gregory C Pratt PhD Kristie Ellickson PhD #12 · Relationships #12;Living near traffic increases exposure to air pollution and is associated with adverse health exposed to traffic and air pollution. They are also more vulnerable and have an increased risk of adverse

Minnesota, University of

93

Social housing policies under changing framework condi-tions in Santiago de Chile  

E-Print Network [OSTI]

unifamiliares en modalidad de autoconstrucción o bloques de viviendas plurifamiliares. Con ello los campamentos de vi- viendas irregulares disminuyeron considerablemente. La política de vivienda social fue

Borsdorf, Axel

94

ROFL: Routing on Flat Labels Matthew Caesar Tyson Condie Jayanthkumar Kannan  

E-Print Network [OSTI]

Lakshminarayanan Ion Stoica Scott Shenker University of California at Berkeley {mccaesar,tcondie,kjk

95

Air Risk Information Support Center  

SciTech Connect (OSTI)

The Air Risk Information Support Center (Air RISC) was initiated in early 1988 by the US Environmental Protection Agency`s (EPA) Office of Health and Environmental Assessment (OHEA) and the Office of Air Quality Planning and Standards (OAQPS) as a technology transfer effort that would focus on providing information to state and local environmental agencies and to EPA Regional Offices in the areas of health, risk, and exposure assessment for toxic air pollutants. Technical information is fostered and disseminated by Air RISCs three primary activities: (1) a {open_quotes}hotline{close_quotes}, (2) quick turn-around technical assistance projects, and (3) general technical guidance projects. 1 ref., 2 figs.

Shoaf, C.R.; Guth, D.J. [Environmental Protection Agency, Washington, DC (United States)

1990-12-31T23:59:59.000Z

96

New Age Teaching: Beyond Didactics  

E-Print Network [OSTI]

Age Teaching: Beyond Didactics TheScientificWorldJOURNAL (New age teaching: beyond didactics. TSW Urology 1, 7585.New Age Teaching: Beyond Didactics Peter D. Vlaovic and

Vlaovic, Peter D; McDougall, Elspeth M

2006-01-01T23:59:59.000Z

97

Electrocatalysts for Nonaqueous LithiumAir Batteries:...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Electrocatalysts for Nonaqueous LithiumAir Batteries: Status, Challenges, and Perspective. Electrocatalysts for Nonaqueous LithiumAir Batteries: Status, Challenges,...

98

Regenerative air heater  

DOE Patents [OSTI]

A gas-cooled steel skirt is used to support a refractory cored brick matrix and dome structure in a high temperature regenerative air heater useful in magnetohydrodynamic power generation. The steel skirt thermally expands to accommodate the thermal expansion of the dome structure despite substantial temperature differential thereby reducing relative movement between the dome bricks. Gas cooling of the steel skirt allows the structure to operate above its normal temperature during clean-out cycles and also allows for the control of the thermal expansion of the steel skirt.

Hasselquist, Paul B. (Maple Grove, MN); Baldner, Richard (Minnetonka, MN)

1982-01-01T23:59:59.000Z

99

Regenerative air heater  

DOE Patents [OSTI]

A gas-cooled steel skirt is used to support a refractory cored brick matrix and dome structure in a high temperature regenerative air heater useful in magnetohydrodynamic power generation. The steel skirt thermally expands to accommodate the thermal expansion of the dome structure despite substantial temperature differential thereby reducing relative movement between the dome bricks. Gas cooling of the steel skirt allows the structure to operate above its normal temperature during clean-out cycles and also allows for the control of the thermal expansion of the steel skirt.

Hasselquist, P.B.; Baldner, R.

1980-11-26T23:59:59.000Z

100

Safeguarding indoor air quality  

SciTech Connect (OSTI)

California has created and implemented the first state program devoted exclusively to the investigation of nonindustrial indoor air quality. The program is responsible for promoting and conducting research on the determining factors of healthful indoor environments and is structured to obtain information about emission sources, ventilation effects, indoor concentrations, human activity patterns, exposures, health risks, control measures and public policy options. Data are gathered by a variety of methods, including research conducted by staff members, review of the available scientific literature, participation in technical meetings, contractual agreements with outside agencies, cooperative research projects with other groups and consultation with experts. 23 references, 1 figure, 1 table.

Sexton, K.; Wesolowski, J.J.

1985-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Hot air drum evaporator  

DOE Patents [OSTI]

An evaporation system for aqueous radioactive waste uses standard 30 and 55 gallon drums. Waste solutions form cascading water sprays as they pass over a number of trays arranged in a vertical stack within a drum. Hot dry air is circulated radially of the drum through the water sprays thereby removing water vapor. The system is encased in concrete to prevent exposure to radioactivity. The use of standard 30 and 55 gallon drums permits an inexpensive compact modular design that is readily disposable, thus eliminating maintenance and radiation build-up problems encountered with conventional evaporation systems.

Black, Roger L. (Idaho Falls, ID)

1981-01-01T23:59:59.000Z

102

Aging in community  

E-Print Network [OSTI]

Baby Boomers are on the brink of retirement. According to U.S. Census Bureau projections, the number of people aged 65 and over will more than double in the coming decades, growing from 35 million in 2000 to 72 million in ...

Fay, Justin (Justin Thomas)

2008-01-01T23:59:59.000Z

103

Abatement of Air Pollution: Air Pollution Control Equipment and...  

Broader source: Energy.gov (indexed) [DOE]

contain instructions for the operation and monitoring of air pollution control equipment, as well as comments on procedures in the event of equipment breakdown, failure, and...

104

Air Force Renewable Energy Programs  

Broader source: Energy.gov [DOE]

Presentation covers Air Force Renewable Energy Programs and is given at the Spring 2011 Federal Utility Partnership Working Group (FUPWG) meeting.

105

Oklahoma Clean Air Act (Oklahoma)  

Broader source: Energy.gov [DOE]

This legislation establishes the authority for the Oklahoma Department of Environmental Quality to administer programs to maintain and monitor air quality across Oklahoma. The Department monitors...

106

Nebraska Air Quality Regulations (Nebraska)  

Broader source: Energy.gov [DOE]

These regulations, promulgated by the Department of Environmental Quality, contain provisions pertaining to ambient air quality standards, pollution source operating permits, emissions reporting,...

107

Air Liquide - Biogas & Fuel Cells  

Broader source: Energy.gov (indexed) [DOE]

Liquide - Biogas & Fuel Cells Hydrogen Energy Biogas Upgrading Technology 12 June 2012 Charlie.Anderson@airliquide.com 2 Air Liquide, world leader in gases for industry,...

108

Longevity of Duct Tape in Residential Air Distribution Systems: 1-D, 2-D, and 3-D Joints  

E-Print Network [OSTI]

This paper addresses the effectiveness of using duct tape in sealing residential air distribution systems through two laboratory longevity tests. The first test involved the aging of common core-to-collar joints of flexible duct to sheet metal...

Abushakra, B.

2003-01-01T23:59:59.000Z

109

Concrete containment aging study  

SciTech Connect (OSTI)

In 1989, IAEA initiated a pilot study on the management of aging of nuclear power plant components. The Phase I and II studies of concrete containment are discussed. With the data base, plant owners will be able to review and enhance their existing programs. IAEA will analyze data provided by participating plants and the report is scheduled to be released by late 1994 (final report release mid-1995).

Pachner, J. [International Atomic Energy Agency, Vienna (Austria); Tai, T.M. [Bechtel National, Inc., Oak Ridge, TN (United States); Naus, D. [Oak Ridge National Lab., TN (United States)

1994-04-01T23:59:59.000Z

110

An air line carries air at 800 kPa and 80C. An Air line ~ O O C insulated tank initially contains 20C air at a  

E-Print Network [OSTI]

An air line carries air at 800 kPa and 80°C. An Air line ~ O O C insulated tank initially contains 20°C air at a pressure of 90kPa. The valve is opened, and air flows into the tank. Determine the final temperature of the air in the tank and the mass of air that enters the tank if the valve is left

Huang, Haimei

111

Inhalation intake of ambient air pollution in California's South Coast Air Basin  

E-Print Network [OSTI]

the impacts on air pollution and health of urban areaas a proxy for air pollution health effects (Bennett etFuel combustion, air pollution exposure, and health: The

Marshall, Julian D.; Granvold, Patrick W.; Hoats, Abigail S.; McKone, Thomas E.; Deakin, Elizabeth; Nazaroff, William W.

2006-01-01T23:59:59.000Z

112

ORIGINAL ARTICLE Ambient Air Pollution  

E-Print Network [OSTI]

ORIGINAL ARTICLE Ambient Air Pollution and Respiratory Emergency Department Visits Jennifer L. Peel pollution and respiratory outcomes. More refined assessment has been limited by study size and available air quality data. Methods: Measurements of 5 pollutants (particulate matter PM10 , ozone, nitrogen dioxide NO2

Mulholland, James A.

113

Air Force Enhanced Use Lease  

Broader source: Energy.gov (indexed) [DOE]

S e r v i c e - E x c e l l e n c e Headquarters U.S. Air Force 1 Air Force Enhanced Use Lease Mr. Brian Brown 16 Oct. 12 I n t e g r i t y - S e r v i c e - E x c e l l e n c e 2...

114

Environmental Aspects of Air Transportation  

E-Print Network [OSTI]

Innovation Center #12;2 Aviation and Climate #12;3 Combustion Products Commercial jet fuel is essentially FOR AIR TRANSPORTATIONCENTER FOR AIR TRANSPORTATION SYSTEMS RESEARCHSYSTEMS RESEARCH Metron Aviation GMU, and the process inside real engines is considerably more complex. Typical emission rates for jet aircraft (grams

115

Air Force Renewable Energy Programs  

Broader source: Energy.gov (indexed) [DOE]

in All We Do" I n t e g r i t y - S e r v i c e - E x c e l l e n c e THINK GREEN, BUILD GREEN, Topics Air Force Energy Use Air Force Facility Energy Center Current RE...

116

Protective supplied breathing air garment  

DOE Patents [OSTI]

A breathing air garment is disclosed for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap. 17 figs.

Childers, E.L.; Hortenau, E.F. von.

1984-07-10T23:59:59.000Z

117

Air Leakage and Air Transfer Between Garage and Living Space  

SciTech Connect (OSTI)

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

Rudd, A.

2014-09-01T23:59:59.000Z

118

Public Health Air Surveillance Evaluation Project Public Health Air Surveillance Evaluation (PHASE) Project  

E-Print Network [OSTI]

Public Health Air Surveillance Evaluation Project Public Health Air Surveillance Evaluation (PHASE) Project Evaluating, Developing, and Delivering Air Quality Characterization Data to Environmental Public Public Health Tracking (EPHT) Network. The EPA is developing routinely available air quality information

119

Analysis of a Dedicated Outdoor Air System and Low Temperature Supply Air Conditioning System  

E-Print Network [OSTI]

This paper presents the principles and the characteristics of a dedicated outdoor air system (DOAS) and low temperature supply air system. DOAS is offered based on the demands of indoor air quality and the low temperature supply air system...

Guang, L.; Li, R.

2006-01-01T23:59:59.000Z

120

AIR LECTURES HANDOUT 3 P Rhines 21 Feb 03 AIR: THE SMALL (AIR POLLUTION)  

E-Print Network [OSTI]

­ coal smoke in winter (home heating) with clear air, radiational cooling stratifies air SMOG- warm of Science Technology and Environment ( www.pcd.go.th ). Site Location SO2 SO2 * NO2 NO2 * CO (1hr) CO (1hr small for this fluid cleaning mechanism to work. It is the smallest particles that can reach

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

INEEL AIR MODELING PROTOCOL ext  

SciTech Connect (OSTI)

Various laws stemming from the Clean Air Act of 1970 and the Clean Air Act amendments of 1990 require air emissions modeling. Modeling is used to ensure that air emissions from new projects and from modifications to existing facilities do not exceed certain standards. For radionuclides, any new airborne release must be modeled to show that downwind receptors do not receive exposures exceeding the dose limits and to determine the requirements for emissions monitoring. For criteria and toxic pollutants, emissions usually must first exceed threshold values before modeling of downwind concentrations is required. This document was prepared to provide guidance for performing environmental compliance-driven air modeling of emissions from Idaho National Engineering and Environmental Laboratory facilities. This document assumes that the user has experience in air modeling and dose and risk assessment. It is not intended to be a "cookbook," nor should all recommendations herein be construed as requirements. However, there are certain procedures that are required by law, and these are pointed out. It is also important to understand that air emissions modeling is a constantly evolving process. This document should, therefore, be reviewed periodically and revised as needed. The document is divided into two parts. Part A is the protocol for radiological assessments, and Part B is for nonradiological assessments. This document is an update of and supersedes document INEEL/INT-98-00236, Rev. 0, INEEL Air Modeling Protocol. This updated document incorporates changes in some of the rules, procedures, and air modeling codes that have occurred since the protocol was first published in 1998.

C. S. Staley; M. L. Abbott; P. D. Ritter

2004-12-01T23:59:59.000Z

122

AIR LEAKAGE OF NEWLY INSTALLED RESIDENTIAL WINDOWS  

E-Print Network [OSTI]

Tables 2.0.2a 2.0.2b PAGE Air Leakage Through Sash/FrameOperation Types . . . . . Air Leakage of Installed WindowsComparison of Window Types Air Leakage Performance of

Weidt, John

2013-01-01T23:59:59.000Z

123

Air movement preferences observed in office buildings  

E-Print Network [OSTI]

Movement Good or Bad? Indoor Air 14: 40-45. Toftum, J (Quality Survey. Indoor Air 14 (8): 6574. Internationalon the Perception of Indoor Air Quality during Immediate and

2007-01-01T23:59:59.000Z

124

Compressed Air 101: Getting Compressed Air to Work  

E-Print Network [OSTI]

plant energy use. Furthermore, air compression is inefficient with up to 95% of compressor power dissipated as heat. Thus even minor improvements in system operation, control strategies, and efficiency can yield large energy savings and significant non-energy...

Burke, J. J.; Bessey, E. G.

125

Air pollution kills. So what? Air quality engineering to improve public health  

E-Print Network [OSTI]

9/14/12 1 Air pollution kills. So what? Air quality engineering to improve public health;9/14/12 2 Air Quality Engineering H Air Quality Engineering H #12;9/14/12 3 Really? Air pollution running out of coffins and florists were running out of flowers. -- BBC #12;9/14/12 4 Air pollution

Levinson, David M.

126

Air Leakage of Furnaces and Air Handlers Iain S. Walker, Mike Lubliner, Darryl Dickerhoff,  

E-Print Network [OSTI]

Air Leakage of Furnaces and Air Handlers of California. #12;1 Air Leakage of Furnaces and Air Handlers Iain S. Walker, LBNL Mike Lubliner, Washington been made in reducing air leakage in residential and to a lesser extent small commercial forced air

127

U.S. Air Force Fact Sheet Air Force Reserve Officer Training Corps  

E-Print Network [OSTI]

U.S. Air Force Fact Sheet Air Force Reserve Officer Training Corps Mission Develop Quality Leaders for the Air Force. Personnel and Resources Air Force Reserve Officer Training Corps (ROTC) includes four,796 new Second Lieutenants who entered active duty in the United States Air Force. Organization Air Force

Su, Xiao

128

WearAir: Expressive T-shirts for Air Quality Sensing Sunyoung Kim and Eric Paulos  

E-Print Network [OSTI]

are less proactively concerned with air quality. AIR POLLUTANT: VOLATILE ORGANIC COMPOUNDS Different types of air pollutants contribute to air quality in different locations: Ozone, CO, NOx and VOCs are major contributors to outdoor air pollution; and particulate matters, VOCs, carbon monoxide and lead are common air

Mankoff, Jennifer

129

CSP Tower Air Brayton Combustor  

Broader source: Energy.gov [DOE]

This fact sheet describes a concentrating solar power tower air Brayton combustor project awarded under the DOE's 2012 SunShot CSP R&D award program. The team, led by the Southwest Research Institute, is working to develop an external combustor that allows for the mixing of CSP-heated air with natural gas in hybridized power plants. This project aims to increase the temperature capabilities of the CSP tower air receiver and gas turbine to 1,000C and achieve energy conversion efficiencies greater than 50%.

130

Inertial impaction air sampling device  

DOE Patents [OSTI]

An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

Dewhurst, K.H.

1987-12-10T23:59:59.000Z

131

Inertial impaction air sampling device  

DOE Patents [OSTI]

An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry.

Dewhurst, Katharine H. (13150 Wenonah SE. Apt. 727, Albuquerque, NM 87123)

1990-01-01T23:59:59.000Z

132

Inertial impaction air sampling device  

DOE Patents [OSTI]

An inertial impactor is designed which is to be used in an air sampling device for collection of respirable size particles in ambient air. The device may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

Dewhurst, K.H.

1990-05-22T23:59:59.000Z

133

The investigation of exhaust powered, automotive air cycle air conditioning  

E-Print Network [OSTI]

domestic automobiles and trucks because of its proven success. This system requires approximately 4 hp (2. 983 kW)[3] for operation snd employs a pressurized fluorinated hydrocarbon (R-12), hereafter fluorocarbon, as a refrigerant. Most of the research... extraction and avoid the use of a fluorocarbon refrigerant. The maJority of work involved with the new units has associated itself in the area of utilizing an absorption cycle or air cycle. The absorption air conditioning unit differs significantly from...

Holley, James Andrew

1978-01-01T23:59:59.000Z

134

Integrated Technology Air Cleaners (ITAC): Design and Evaluation  

E-Print Network [OSTI]

of particle air filtration technologies." Indoor Air 12(4):2011a). New air cleaning technologies for reduced commercialnumber 2 Integrated technology air cleaner High efficiency

Fisk, William J.

2014-01-01T23:59:59.000Z

135

Reference Inside KS1992 Tray Inside Air  

E-Print Network [OSTI]

Reference Inside KS1992 0.2 Tray Inside Air 0.5 Tray Inside Air 0.8 Tray Inside Air 0.2 Tray Side Wall Inner 0.2 Tray Side Wall Inner Under TAMP near sensor pos4 Under TAMP near sensor pos4 Air Gap Below TDIG pos1 Air Gap Below TDIG pos4 Air Gap Below TDIG pos6 HPTDC1 Chip pos6 HPTDC4 Chip pos6 HPTDC2

Llope, William J.

136

COMBUSTION-GENERATED INDOOR AIR POLLUTION  

E-Print Network [OSTI]

The Status of Indoor Air Pollution Research 1976. GeometNovakov, T. : Formation of Pollution Particulate NitrogenGENERATED INDOOR AIR POLLUTION Dr. C. D. Hollowell, Dr. R.

Hollowell, C.D.

2010-01-01T23:59:59.000Z

137

Stochastic Microenvironment Models for Air Pollution Exposure  

E-Print Network [OSTI]

human exposure to air pollution." SIMS Technical Report No.human exposure to air pollution." Environment International.Annual Meeting of the A i r Pollution Control Association,

Naihua Duan

2011-01-01T23:59:59.000Z

138

Colorado Air Pollution Control Division - Construction Permits...  

Open Energy Info (EERE)

Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: Colorado Air Pollution Control Division - Construction Permits Forms and Air Pollutant Emission...

139

Kansas Air Quality Regulations (Kansas)  

Broader source: Energy.gov [DOE]

All new air contaminant emission sources or alterations to emission sources that are required to be reported shall be in compliance with all applicable emission control regulations at the time that...

140

Kansas Air Quality Act (Kansas)  

Broader source: Energy.gov [DOE]

No person shall construct, own, operate, install, alter or use any air contaminant emission stationary source which, in accordance with rules and regulations, the secretary finds may cause or...

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Missouri Air Conservation Law (Missouri)  

Broader source: Energy.gov [DOE]

This law's purpose is to maintain the purity of the air resources of the state to protect the health, general welfare and physical property of the people, maximum employment and the full industrial...

142

Optimization of Air Conditioning Cycling  

E-Print Network [OSTI]

on a 3-ton residential air conditioner are then presented to intuitively understand the effect of expansion valve and evaporator fan cycling in a real system. A real time optimization method is explored and the feasibility, recommendations for a...

Seshadri, Swarooph

2012-10-19T23:59:59.000Z

143

Computer Room Fresh Air Cooling  

E-Print Network [OSTI]

This paper discusses the concept of a computer room fresh air cooling system with evaporative humidification. The system offers significantly lower energy consumption than conventional cooling units, with 24% reduction for Dallas and 56% reduction...

Wenger, J. D.

1985-01-01T23:59:59.000Z

144

Compressed Air Audits using AIRMaster  

E-Print Network [OSTI]

&M measures. An introduction to the AIRMaster software is provided. Goals The project goals were to develop and test a method and tools to perform Compressed Air System audits. The audits should use only simple instrumentation during a relatively short... air system leaks. 2. AIRMaster Software and User's Manual. AIRMaster is a spreadsheet-based program that can model part load system operation with up to five rotary screw and reciprocating compressors operating simultaneously with varying...

Wheeler, G. M.; McGill, R. D.; Bessey, E. G.; Vischer, K.

145

Optimising the Fresh Air Economiser  

E-Print Network [OSTI]

, S., ?Economizers in Air Handling Systems?, CED Engineering Course M01-014, Stony Point New York, 2000. Moser, D., ?Free Cooling: Don?t Let Savings Slip Away?, Portland Energy Conservation Inc., published in Building Operating Management.... New Zealand, Standard NZS 4303:1990, Ventilation for Acceptable Indoor Air Quality, Standards Association of New Zealand, Wellington. Portland Energy Conservation Inc., from Functional Testing Guide on website: (http...

Biship, R.

2013-01-01T23:59:59.000Z

146

Small Break Air Ingress Experiment  

SciTech Connect (OSTI)

The small break air-ingress experiment, described in this report, is designed to investigate air-ingress phenomena postulated to occur in pipes in a very high temperature gas-cooled reactor (VHTRs). During this experiment, air-ingress rates were measured for various flow and break conditions through small holes drilled into a pipe of the experimental apparatus. The holes were drilled at right angles to the pipe wall such that a direction vector drawn from the pipe centerline to the center of each hole was at right angles with respect to the pipe centerline. Thus the orientation of each hole was obtained by measuring the included angle between the direction vector of each hole with respect to a reference line anchored on the pipe centerline and pointing in the direction of the gravitational force. Using this reference system, the influence of several important parameters on the air ingress flow rate were measured including break orientation, break size, and flow velocity . The approach used to study the influence of these parameters on air ingress is based on measuring the changes in oxygen concentrations at various locations in the helium flow circulation system as a function of time using oxygen sensors (or detectors) to estimate the air-ingress rates through the holes. The test-section is constructed of a stainless steel pipe which had small holes drilled at the desired locations.

Chang Oh; Eung Soo Kim

2011-09-01T23:59:59.000Z

147

Microstructural Features in Aged Erbium Tritide Foils  

SciTech Connect (OSTI)

Aged erbium tritide foil specimens are found to contain five distinctly different microstructural features. The general structure was of large columnar grains of ErT2. But on a fine scale, precipitates believed to be erbium oxy-tritides and helium bubbles could be identified. The precipitate size was in the range of ~10 nm and the bubbles were of an unusual planar shape on {111} planes with an invariant thickness of ~1 nm and a diameter on the order of 10 nm. Also, an outer layer containing no fine precipitate structure and only a few helium bubbles was present on foils. This layer is best described as a denuded zone which probably grew during aging in air. Finally, large embedded Er2O3 particles were found at low density and non-uniformly distributed, but sometimes extending through the thickness of the foil. A failure mechanism allowing the helium to escape is suggested by observed cracking between bubbles closer to end of life.

Gelles, David S.; Brewer, L. N.; Kotula, Paul G.; Cowgill, Donald F.; Busick, C. C.; Snow, C. S.

2008-01-01T23:59:59.000Z

148

Aging and functional brain networks  

SciTech Connect (OSTI)

Aging is associated with changes in human brain anatomy and function and cognitive decline. Recent studies suggest the aging decline of major functional connectivity hubs in the 'default-mode' network (DMN). Aging effects on other networks, however, are largely unknown. We hypothesized that aging would be associated with a decline of short- and long-range functional connectivity density (FCD) hubs in the DMN. To test this hypothesis, we evaluated resting-state data sets corresponding to 913 healthy subjects from a public magnetic resonance imaging database using functional connectivity density mapping (FCDM), a voxelwise and data-driven approach, together with parallel computing. Aging was associated with pronounced long-range FCD decreases in DMN and dorsal attention network (DAN) and with increases in somatosensory and subcortical networks. Aging effects in these networks were stronger for long-range than for short-range FCD and were also detected at the level of the main functional hubs. Females had higher short- and long-range FCD in DMN and lower FCD in the somatosensory network than males, but the gender by age interaction effects were not significant for any of the networks or hubs. These findings suggest that long-range connections may be more vulnerable to aging effects than short-range connections and that, in addition to the DMN, the DAN is also sensitive to aging effects, which could underlie the deterioration of attention processes that occurs with aging.

Tomasi D.; Tomasi, D.; Volkow, N.D.

2011-07-11T23:59:59.000Z

149

Relative Ages of Globular Clusters  

E-Print Network [OSTI]

Ages of extragalactic globular clusters can provide valuable insights into the formation and evolution of galaxies. In this contribution the photometric methods of age dating old globular cluster systems are summarised. The spectroscopic approach is reviewed with an emphasis of the right choice of age diagnostics. We present a new method of quantifying the relatively best age-sensitive spectroscopic index given the quality of a data set and a certain theoretical stellar synthesis model. The relatively best diagnostic plot is constructed from the set of Lick indices and used to age date globular clusters in several early-type galaxies which are part of a large spectroscopic survey of extragalactic globular cluster systems. We find that, independently of host galaxy, metal-poor ([Fe/H] 8 Gyr) and coeval. Metal-rich clusters show a wide range of ages from ~15 down to a few Gyr.

Thomas H. Puzia

2002-10-18T23:59:59.000Z

150

Introduction Air Quality and Nitrogen Dioxide  

E-Print Network [OSTI]

- Global update 2005. Primary sources of air pollutants include combustion products from power generationIntroduction Air Quality and Nitrogen Dioxide Air pollution can be defined as "the presence effects to man and/or the environment". (DEFRA) "Clean air is considered to be a basic requirement

151

Air UCI Summer Training Program in Environmental  

E-Print Network [OSTI]

Air UCI Summer Training Program in Environmental Chemistry for Science Teachers I. July 11 ­ July · Lectures by AirUCI faculty · Lab tours of AirUCI laboratories · Follow-up for several years Distribution Models and predictions. Syllabus: Lectures Every AirUCI faculty member is actively involved

Nizkorodov, Sergey

152

Chapter 22: Compressed Air Evaluation Protocol  

SciTech Connect (OSTI)

Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: high-efficiency/variable speed drive (VSD) compressor replacing modulating compressor; compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.

Benton, N.

2014-11-01T23:59:59.000Z

153

AGING FACILITY WORKER DOSE ASSESSMENT  

SciTech Connect (OSTI)

The purpose of this calculation is to estimate radiation doses received by personnel working in the Aging Facility performing operations to transfer aging casks to the aging pads for thermal and logistical management, stage empty aging casks, and retrieve aging casks from the aging pads for further processing in other site facilities. Doses received by workers due to aging cask surveillance and maintenance operations are also included. The specific scope of work contained in this calculation covers both collective doses and individual worker group doses on an annual basis, and includes the contributions due to external and internal radiation from normal operation. There are no Category 1 event sequences associated with the Aging Facility (BSC 2004 [DIRS 167268], Section 7.2.1). The results of this calculation will be used to support the design of the Aging Facility and to provide occupational dose estimates for the License Application. The calculations contained in this document were developed by Environmental and Nuclear Engineering of the Design and Engineering Organization and are intended solely for the use of the Design and Engineering Organization in its work regarding facility operation. Yucca Mountain Project personnel from the Environmental and Nuclear Engineering should be consulted before use of the calculations for purposes other than those stated herein or use by individuals other than authorized personnel in Environmental and Nuclear Engineering.

R.L. Thacker

2005-03-24T23:59:59.000Z

154

Lessons learned in modeling Underfloor Air Distribution system  

E-Print Network [OSTI]

Underfloor Air Distribution (UFAD) Design Guide. Atlanta:for design cooling loads in underfloor air distribution (

Lee, Kwang Ho; Schiavon, Stefano; Webster, Tom; Bauman, Fred; Feng, Jingjuan; Hoyt, Tyler

2011-01-01T23:59:59.000Z

155

Blind teen-age students' expectations Focus: school-age  

E-Print Network [OSTI]

Blind teen-age students' expectations Focus: school-age Topic: What are the changing demands disabled pupils, inclusion increased significantly, particularly in high schools. Blind learners, who used. For this lecture, I will present a few blind students' opinions, which will help building the items for the case

Paris-Sud XI, Universit de

156

Considering Air Density in Wind Power Production  

E-Print Network [OSTI]

In the wind power production calculations the air density is usually considered as constant in time. Using the CIPM-2007 equation for the density of moist air as a function of air temperature, air pressure and relative humidity, we show that it is worth taking the variation of the air density into account, because higher accuracy can be obtained in the calculation of the power production for little effort.

Farkas, Zn

2011-01-01T23:59:59.000Z

157

Considering Air Density in Wind Power Production  

E-Print Network [OSTI]

In the wind power production calculations the air density is usually considered as constant in time. Using the CIPM-2007 equation for the density of moist air as a function of air temperature, air pressure and relative humidity, we show that it is worth taking the variation of the air density into account, because higher accuracy can be obtained in the calculation of the power production for little effort.

Zn Farkas

2011-03-11T23:59:59.000Z

158

Air Pollution 7.1 INTRODUCTION  

E-Print Network [OSTI]

CHAPTER 7 Air Pollution 7.1 INTRODUCTION 7.2 OVERVIEW OF EMISSIONS 7.3 THE CLEAN AIR ACT 7.4 THE POLLUTANT STANDARDS INDEX 7.5 CRITERIA POLLUTANTS 7.6 TOXIC AIR POLLUTANTS 7.7 AIR POLLUTION IN THE WORLD'S MEGACITIES 7.8 MOTOR VEHICLE EMISSIONS 7.9 STATIONARY SOURCES 7.10 AIR POLLUTION AND METEOROLOGY 7

Kammen, Daniel M.

159

AIRS Version 6 Release Level 2 Product User Guide AIRS/AMSU/HSB Version 6  

E-Print Network [OSTI]

AIRS Version 6 Release Level 2 Product User Guide Page 1 AIRS/AMSU/HSB Version 6 Level 2 Product Questions to: http://airs.jpl.nasa.gov/AskAirs #12;AIRS Version 6 Release Level 2 Product User Guide Page 2............................................................................................. 7 1.1 EXAMPLE: LEVEL 2 PHYSICAL RETRIEVAL PRODUCT FILE NAMES

Waliser, Duane E.

160

Residential Forced Air System Cabinet Leakage and Blower Performance  

E-Print Network [OSTI]

DrivenUnitary Air?ConditioningandHeatPumpEquipment. AirConditioning& Air?sourceHeatPumpEquipment. Air?applytotheairhandlersofheatpumpsandelectric

Walker, Iain S.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Design Evolution Study - Aging Options  

SciTech Connect (OSTI)

The purpose of this study is to identify options and issues for aging commercial spent nuclear fuel received for disposal at the Yucca Mountain Mined Geologic Repository. Some early shipments of commercial spent nuclear fuel to the repository may be received with high-heat-output (younger) fuel assemblies that will need to be managed to meet thermal goals for emplacement. The capability to age as much as 40,000 metric tons of heavy metal of commercial spent nuclear he1 would provide more flexibility in the design to manage this younger fuel and to decouple waste receipt and waste emplacement. The following potential aging location options are evaluated: (1) Surface aging at four locations near the North Portal; (2) Subsurface aging in the permanent emplacement drifts; and (3) Subsurface aging in a new subsurface area. The following aging container options are evaluated: (1) Complete Waste Package; (2) Stainless Steel inner liner of the waste package; (3) Dual Purpose Canisters; (4) Multi-Purpose Canisters; and (5) New disposable canister for uncanistered commercial spent nuclear fuel. Each option is compared to a ''Base Case,'' which is the expected normal waste packaging process without aging. A Value Engineering approach is used to score each option against nine technical criteria and rank the options. Open issues with each of the options and suggested future actions are also presented. Costs for aging containers and aging locations are evaluated separately. Capital costs are developed for direct costs and distributable field costs. To the extent practical, unit costs are presented. Indirect costs, operating costs, and total system life cycle costs will be evaluated outside of this study. Three recommendations for aging commercial spent nuclear fuel--subsurface, surface, and combined surface and subsurface are presented for further review in the overall design re-evaluation effort. Options that were evaluated but not recommended are: subsurface aging in a new subsurface area (high cost); surface aging in the complete waste package (risk to the waste package and impact on the Waste Handling Facility); and aging in the stainless steel liner (impact on the waste package design and new high risk operations added to the waste packaging process). The selection of a design basis for aging will be made in conjunction with the other design re-evaluation studies.

P. McDaniel

2002-04-05T23:59:59.000Z

162

High Energy Efficiency Air Conditioning  

SciTech Connect (OSTI)

This project determined the performance of a new high efficiency refrigerant, Ikon B, in a residential air conditioner designed to use R-22. The refrigerant R-22, used in residential and small commercial air conditioners, is being phased out of production in developed countries beginning this year because of concerns regarding its ozone depletion potential. Although a replacement refrigerant, R-410A, is available, it operates at much higher pressure than R-22 and requires new equipment. R-22 air conditioners will continue to be in use for many years to come. Air conditioning is a large part of expensive summer peak power use in many parts of the U.S. Previous testing and computer simulations of Ikon B indicated that it would have 20 - 25% higher coefficient of performance (COP, the amount of cooling obtained per energy used) than R-22 in an air-cooled air conditioner. In this project, a typical new R-22 residential air conditioner was obtained, installed in a large environmental chamber, instrumented, and run both with its original charge of R-22 and then with Ikon B. In the environmental chamber, controlled temperature and humidity could be maintained to obtain repeatable and comparable energy use results. Tests with Ikon B included runs with and without a power controller, and an extended run for several months with subsequent analyses to check compatibility of Ikon B with the air conditioner materials and lubricant. Baseline energy use of the air conditioner with its original R-22 charge was measured at 90 deg F and 100 deg F. After changeover to Ikon B and a larger expansion orifice, energy use was measured at 90 deg F and 100 deg F. Ikon B proved to have about 19% higher COP at 90 deg F and about 26% higher COP at 100 deg F versus R-22. Ikon B had about 20% lower cooling capacity at 90 deg F and about 17% lower cooling capacity at 100 deg F versus R-22 in this system. All results over multiple runs were within 1% relative standard deviation (RSD). All of these values agree well with previous results and computer simulations of Ikon B performance versus R-22. The lower cooling capacity of Ikon B is not a concern unless a particular air conditioner is near its maximum cooling capacity in application. Typically, oversized A/C systems are installed by contractors to cover contingencies. In the extended run with Ikon B, which lasted about 4.5 months at 100 deg F ambient temperature and 68% compressor on time, the air conditioner performed well with no significant loss of energy efficiency. Post-run analysis of the refrigerant, compressor lubricant oil, compressor, compressor outlet tubing, and the filter/dryer showed minor effects but nothing that was considered significant. The project was very successful. All objectives were achieved, and the performance of Ikon B indicates that it can easily be retrofitted into R-22 air conditioners to give 15 - 20% energy savings and a 1 - 3 year payback of retrofit costs depending on location and use. Ikon B has the potential to be a successful commercial product.

Edward McCullough; Patrick Dhooge; Jonathan Nimitz

2003-12-31T23:59:59.000Z

163

Managing aging in nuclear power plants: Insights from NRC maintenance team inspection reports  

SciTech Connect (OSTI)

A plant`s maintenance program is the principal vehicle through which age-related degradation is managed. From 1988 to 1991, the NRC evaluated the maintenance program of every nuclear power plant in the United States. Forty-four out of a total of 67 of the reports issued on these in-depth team inspections were reviewed for insights into the strengths and weaknesses of the programs as related to the need to understand and manage the effects of aging on nuclear plant systems, structures, and components. Relevant information was extracted from these inspection reports and sorted into several categories, including Specific Aging Insights, Preventive Maintenance, Predictive Maintenance and Condition Monitoring, Post Maintenance Testing, Failure Trending, Root Cause Analysis and Usage of Probabilistic Risk Assessment in the Maintenance Process. Specific examples of inspection and monitoring techniques successfully used by utilities to detect degradation due to aging have been identified. The information also was sorted according to systems and components, including: Auxiliary Feedwater, Main Feedwater, High Pressure Injection for both BWRs and PWRs, Service Water, Instrument Air, and Emergency Diesel Generator Air Start Systems, and Emergency Diesel Generators Air Start Systems, emergency diesel generators, electrical components such as switchgear, breakers, relays, and motor control centers, motor operated valves and check valves. This information was compared to insights gained from the Nuclear Plant Aging Research (NPAR) Program. Attributes of plant maintenance programs where the NRC inspectors felt that improvement was needed to properly address the aging issue also are discussed.

Fresco, A.; Subudhi, M.; Gunther, W.; Grove, E.; Taylor, J. [Brookhaven National Lab., Upton, NY (United States)

1993-12-01T23:59:59.000Z

164

The Air-Fluorescence Yield  

E-Print Network [OSTI]

Detection of the air-fluorescence radiation induced by the charged particles of extensive air showers is a well-established technique for the study of ultra-high energy cosmic rays. Fluorescence telescopes provide a nearly calorimetric measure of the primary energy. Presently the main source of systematic uncertainties comes from our limited accuracy in the fluorescence yield, that is, the number of fluorescence photons emitted per unit of energy deposited in the atmosphere by the shower particles. In this paper the current status of our knowledge on the fluorescence yield both experimental an theoretical will be discussed.

F. Arqueros; F. Blanco; D. Garcia-Pinto; M. Ortiz; J. Rosado

2008-07-30T23:59:59.000Z

165

Leads Tactical Air Control Party (TACP) and Air Support  

E-Print Network [OSTI]

leadership in the demanding environment of Joint operations -Meet medical standards for Ground Based Control as an ALO. Joint Air Operations Command and Control Course: The JAOC2C will provide the 13L ALO an overview, Ranger School, the Joint Operational Fires and Effects Course, and others. initiAL trAining AdvAnced tr

Duchowski, Andrew T.

166

Aging and iodine loading of silver-functionalized aerogels  

SciTech Connect (OSTI)

Engineered silver-functionalized silica aerogels are being investigated for their potential application in off-gas treatment at a used nuclear fuel reprocessing facility. Reprocessing will release several key volatile radionuclides, including iodine-129. To achieve regulatory compliance, iodine-129 must be removed from any off-gas stream prior to environmental discharge. Ag{sup 0}-functionalized aerogels have been demonstrated to have high iodine-capture capacity, high porosity, and potential for conversion into a waste form. Capture materials used in off-gas treatment may be exposed to a heated, high-humidity, acidic gas stream for months. Extended exposure to this stream could affect sorbent performance. It was the aim of this study to evaluate what impacts might be observed when Ag{sup 0}-functionalized aerogels prepared at Pacific Northwest National Laboratory were contacted with a dry air stream for up to 6 months and then used to adsorb iodine from a synthetic off-gas stream. Results demonstrate that there is some loss of iodine-capture capacity caused by aging, but that this loss is not as marked as for aging of more traditional iodine sorbents, such as silver-impregnated mordenite. Specifically, aging silver-functionalized aerogel under a dry air stream for up to 6 months can decrease its iodine capacity from 41 wt% to 32 wt%. (authors)

Bruffey, S.H.; Jubin, R.T.; Anderson, K.K.; Walker, J.F. [Oak Ridge National Laboratory, P.O. Box 2008, MS-6223, Oak Ridge, TN 37831 (United States)

2013-07-01T23:59:59.000Z

167

AGING AND IODINE LOADING OF SILVER-FUNCTIONALIZED AEROGELS  

SciTech Connect (OSTI)

Engineered silver-functionalized silica aerogels are being investigated for their application in off-gas treatment at a used nuclear fuel reprocessing facility. Reprocessing will release several key volatile radionuclides, including iodine-129. To achieve regulatory compliance, iodine-129 must be removed from any off-gas stream prior to environmental discharge. Silver-functionalized aerogels have been demonstrated to have high iodine capture capacity, high porosity and potential for conversion into a waste form. Capture materials used in off-gas treatment may be exposed to a heated, high humidity, acidic gas stream for months. Extended exposure to this stream could affect sorbent performance. It was the aim of this study to evaluate what impacts might be observed when Ag0-functionalized aerogels prepared at Pacific Northwest National Laboratory were contacted with a dry air stream for up to 6 months and then used to adsorb iodine from a synthetic off-gas stream. Results demonstrate that there is some loss of iodine capture capacity caused by aging, but that this loss is not as marked as for aging of more traditional iodine sorbents, such as silver-impregnated mordenite. Specifically, aging silver-functionalized aerogel under a dry air stream for up to 6 months can decrease its iodine capacity from 41wt% to 32wt%.

Bruffey, Stephanie H [ORNL; Jubin, Robert Thomas [ORNL; Anderson, Kaara K [ORNL; Walker Jr, Joseph Franklin [ORNL

2013-01-01T23:59:59.000Z

168

Experience on Commissioning of Heating/Cooling System and Thermal/Air Quality Environment  

E-Print Network [OSTI]

-Insulated and Air-Tightened Residential House in Kansai District, Japan, Proceedings of Healthy Buildings 2000, Espoo, Finland, Vol.2, PP.587-592, 2000.8. 4. T. Shimizu and N. Nakahara, Design and Measurements of an Aged-oriented House Aiming at Healthy...

Hokoi, S.; Miura, H.; Huang, Y.; Nakahara, N.; Iwamae, A.

2004-01-01T23:59:59.000Z

169

Review: Clearing the Air: The Health and Economic Damages of Air Pollution in China  

E-Print Network [OSTI]

and Economic Damages of Air Pollution in China Mun S. Ho andEconomic Damages of Air Pollution in China. Cambridge, MA:the assessment of air pollution and its health and economic

Lee, Joseph

2009-01-01T23:59:59.000Z

170

AIR QUALITY IMPACTS OF LIQUEFIED NATURAL GAS IN THE SOUTH COAST AIR BASIN OF CALIFORNIA  

E-Print Network [OSTI]

Emissions 7.3 Impacts of LNG on Air Quality 8. References 9.El Paso at Blythe. Chapter 3: Air Quality Impact AssessmentRespect to the South Coast Air Quality Management District

Carerras-Sospedra, Marc

2012-01-01T23:59:59.000Z

171

Review: Clearing the Air: The Health and Economic Damages of Air Pollution in China  

E-Print Network [OSTI]

the assessment of air pollution and its health and economiclargest source of health damages of air pollution in China,to air pollution, and the economic evaluations of health

Lee, Joseph

2009-01-01T23:59:59.000Z

172

I) EXAS AIR CONTROL BLAR  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

I) EXAS AIR CONTROL BLAR 6330 HWY. 290 EAST, AUSTIN, TEXAS 78723, 512451-5711 DICK WHmINGTON, P.E. JOHN L. BLAIR CHAIRMAN MARCUS M. KEY, M.D. CALVIN 8. PARNELL, JR., Ph.D., P.E....

173

Micromachinable Leaky Wave Air Transducers  

E-Print Network [OSTI]

reflection coefficient can also in a thin plate as a meam of efficient coupling of ultrasonic energy to air of the ultrasonic energy is a function of the elastic properties of the plate andmost dominantly determinedby lowerleak rates as compared to silicon and aluminum. Since these thin dates aremuch easier to fabricate wine

Khuri-Yakub, Butrus T. "Pierre"

174

Air Quality Conformity Trip Generation  

E-Print Network [OSTI]

Management Districts (AQMDs) and Air Pollution Control Districts (APCDs) #12;Source: http standards #12;PROBLEM #12;http://www.epa.gov/airtrends/2008/graphics/Figure3.gif Progress! #12;http_graph.html #12;http://www.epa.gov/airtrends/2008/graphics/HighlightsNumber.gif Number of people living in non

Handy, Susan L.

175

Lead reduction in ambient air  

SciTech Connect (OSTI)

The Bureau of Mines evaluated the emission control methods, including the capital investments and operating cost, necessary for further reducing lead levels in ambient air at the Glover, Herculaneum, and Buick smelter-refineries in Missouri and the East Helena, MT, smelter. This report presents theoretically achievable lead emission reductions and estimated capital and operating costs.

Smith, R.D.; Kiehn, O.A.; Wilburn, D.R.; Bowyer, R.C.

1987-01-01T23:59:59.000Z

176

Effects of Thermal Aging on the Mechanical Properties of a Porous-Matrix Ceramic Composite  

E-Print Network [OSTI]

Effects of Thermal Aging on the Mechanical Properties of a Porous-Matrix Ceramic Composite Eric A properties of an all-oxide fiber-reinforced composite following long-term exposure (1000 h) at temperatures of 1000­1200°C in air. The composite of interest derives its damage tolerance from a highly porous matrix

Zok, Frank

177

End of the Little Ice Age in the Alps forced by industrial black carbon  

E-Print Network [OSTI]

, Oceanic, and Space Sciences, University of Michigan, Ann Arbor, MI 48109; c Institute of MeteorologyEnd of the Little Ice Age in the Alps forced by industrial black carbon Thomas H. Paintera,1 , Mark and Geophysics, University of Innsbruck, 6020 Innsbruck, Austria; d Air Quality Research Center, University

Marzeion, Ben

178

Aging assessment of essential HVAC chillers used in nuclear power plants. Phase 1, Volume 1  

SciTech Connect (OSTI)

The Pacific Northwest Laboratory conducted a Phase I aging assessment of chillers used in the essential safety air-conditioning systems of nuclear power plants. Centrifugal chillers in the 75- to 750-ton refrigeration capacity range are the predominant type used. The chillers used, and air-conditioning systems served, vary in design from plant-to-plant. It is crucial to keep chiller internals very clean and to prevent the leakage of water, air, and other contaminants into the refrigerant containment system. Periodic operation on a weekly or monthly basis is necessary to remove moisture and noncondensable gases that gradually build up inside the chiller. This is especially desirable if a chiller is required to operate only as an emergency standby unit. The primary stressors and aging mechanisms that affect chillers include vibration, excessive temperatures and pressures, thermal cycling, chemical attack, and poor quality cooling water. Aging is accelerated by moisture, non-condensable gases (e.g., air), dirt, and other contamination within the refrigerant containment system, excessive start/stop cycling, and operating below the rated capacity. Aging is also accelerated by corrosion and fouling of the condenser and evaporator tubes. The principal cause of chiller failures is lack of adequate monitoring. Lack of performing scheduled maintenance and human errors also contribute to failures.

Blahnik, D.E.; Klein, R.F. [Pacific Northwest Lab., Richland, WA (United States)

1993-09-01T23:59:59.000Z

179

CATEE: Clean Air Through Energy Efficiency Conference  

E-Print Network [OSTI]

and musts often resort to drugs to alleviate symptoms. Research shows that people spend over 50% of their time at home indoors. Consumer awareness of IAQ is growing Why IAQ Matters 2014 CirrusAir Technologies, Inc Sources: EPA, State of the Air... Household cleaners 2014 CirrusAir Technologies, Inc ESL-KT-14-11-27 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 Current Filtration Systems 2014 CirrusAir Technologies, Inc The increased need for indoor air quality...

Tillman, S.

2014-01-01T23:59:59.000Z

180

AGING SYSTEM DESIGN DEVELOPMENT STRATEGY  

SciTech Connect (OSTI)

This plan provides an overview, work to date, and the path forward for the design development strategy of the Aging cask for aging commercial spent nuclear fuel (CSNF) at the Yucca Mountain Project (YMP) repository site. Waste for subsurface emplacement at the repository includes US Department of Energy (DOE) high-level radioactive waste (HLW), DOE SNF, commercial fuel in dual-purpose canisters (DPCs), uncanistered bare fuel, naval fuel, and other waste types. Table 1-1 lists the types of radioactive materials that may be aged at YMP, and those materials that will not be placed in an aging cask or module. This plan presents the strategy for design development of the Aging system. The Aging system will not handle naval fuel, DOE HLW, MCOs, or DOE SNF since those materials will be delivered to the repository in a state and sequence that allows them to be placed into waste packages for emplacement. Some CSNF from nuclear reactors, especially CSNF that is thermally too hot for emplacement underground, will need to be aged at the repository.

J. Beesley

2005-02-07T23:59:59.000Z

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

E-Print Network 3.0 - air-to-air heat pumps Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

conditions... data on the seasonal performance of air-to-air residential heat pump systems. The purpose of this paper... of operation 10, 197778, the Control House ......

182

E-Print Network 3.0 - air temperature air Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

measured as 74 per of air flowing through the turbine. The turbine operates... the ideal gas model for air, determine the turbine efficiency. Problem 2 ... Source: Bahrami, Majid -...

183

Cell Senescence: Aging and Cancer  

ScienceCinema (OSTI)

Scientists have identified a molecular cause behind the ravages of old age and in doing so have also shown how a natural process for fighting cancer in younger persons can actually promote cancer in older individuals.

Campisi, Judith

2013-05-29T23:59:59.000Z

184

Malcolm Guite Poets in Age  

E-Print Network [OSTI]

Malcolm Guite Poets in Age or A Study of Reading Habits At first I used to wish that I were Keats passing bell is rung. But now I need the poets who grew old And wore the bottoms of their trousers rolled of pure gold. I need the poets now, who match my age, Like Coleridge I could become a sage, And I bet I

Robertson, Stephen

185

Evolution of US air cargo productivity  

E-Print Network [OSTI]

This thesis provides an overview of the US air cargo industry since airline deregulation in 1978, including a brief overview of the historical evolution of air cargo transport in the US from the early 1900s until the late ...

Donatelli, David J

2012-01-01T23:59:59.000Z

186

Seneca Compressed Air Energy Storage (CAES) Project  

SciTech Connect (OSTI)

This document provides specifications for the process air compressor for a compressed air storage project, requests a budgetary quote, and provides supporting information, including compressor data, site specific data, water analysis, and Seneca CAES value drivers.

None

2012-11-30T23:59:59.000Z

187

Air America: Upholding the Airmen's Bond  

E-Print Network [OSTI]

. Ed Adams, Air America, Conducted rescue operations in Laos and South Vietnam Mr. Marius Burke, Air America, Conducted rescue operations in Laos and South Vietnam Mr. Robert Grealy, CIA, Retired Senior

Kilgard, Michael P.

188

Master Control of Multiple Air Compressors  

E-Print Network [OSTI]

A single master air pressure controller for several machines can reduce air pressure variation by having a single set-point for all machines. This master control when coupled to a sequencing control package allows positively loading the combination...

Petzold, M. A.

1983-01-01T23:59:59.000Z

189

Chapter 53 Ambient Air Quality (Kentucky)  

Broader source: Energy.gov [DOE]

Kentucky Administrative Regulation Chapter 53, entitled Ambient Air Quality, is promulgated under the authority of the Division of Air Quality within the Energy and Environment Cabinets Department...

190

Clean Air Act of Montana (Montana)  

Broader source: Energy.gov [DOE]

The purpose of the Clean Air Act of Montana is to achieve and maintain levels of air quality to "protect human health and safety and, to the greatest degree practicable, prevent injury to plant and...

191

Ambient Air Quality Criteria (Manitoba, Canada)  

Broader source: Energy.gov [DOE]

The Manitoba Ambient Air Quality Criteria schedule lists maximum time-based pollutant concentration levels for the protection and preservation of ambient air quality within the Province of Manitoba...

192

General Provisions on Air Pollution Control (Ohio)  

Broader source: Energy.gov [DOE]

This chapter of the law that establishes the Ohio Environmental Protection Agency outlines the air pollution rules to secure and maintain levels of air quality that are consistent with the...

193

2012 National Tribal Forum on Air Quality  

Broader source: Energy.gov [DOE]

The Institute for Tribal Environmental Professionals (ITEP) and the National Tribal Air Association (NTAA) would like to invite you to attend their joint air quality conference, the National Tribal...

194

A New Approach to Industrial Air Conditioning  

E-Print Network [OSTI]

-dryer Systems Division, has marketed industrial drying machinery. These heat reactivated dryers can handle latent loads in industrial air conditioning systems. Through waste heat conservation, air conditioning costs can be reduced 25 to 50%, with applications...

Gravenstreter, T.

1982-01-01T23:59:59.000Z

195

Advanced Management of Compressed Air Systems  

Office of Energy Efficiency and Renewable Energy (EERE)

Find out how a compressed air system works and the benefits of optimal compressed air system performance. This training is designed to help end users as well as industry solution providers learn...

196

EVENT CLOUDS : lighter than air architectural structures  

E-Print Network [OSTI]

EVENT CLOUD is a versatile covering system that allows events to happen independently to weather conditions. It consists of a lighter than air pneumatic structure, filled either with helium or hot air, that covers spaces ...

Peydro Duclos, Ignacio

2014-01-01T23:59:59.000Z

197

Clean Air Act Amendments of 1990  

E-Print Network [OSTI]

Congress is currently debating amendments to the Clean Air Act which would strengthen and enhance the current Clean Air Act. The bill would guarantee a reduction of 10 million tons of sulfur dioxide from 1980 levels; would sharply reduce pollutants...

Hanneschlager, R. E.

198

Air Sealing Your Home | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

for air leaks in common trouble spots in your home. What does this mean for me? Save money and energy by air sealing your house. Caulking and weatherstripping are simple,...

199

Arkansas Air Pollution Control Code (Arkansas)  

Broader source: Energy.gov [DOE]

The Arkansas Air Pollution Control code is adopted pursuant to Subchapter 2 of the Arkansas Water and Air Pollution Control Act (Arkansas Code Annotated 8-4-101). ) By authority of the same State...

200

Georgia Air Quality Control Act (Georgia)  

Broader source: Energy.gov [DOE]

The Georgia Air Quality Control Act (AQCA) is a set of environmental regulations, permitting requirements, and air quality standards that control the amount of pollutants emitted and who emits them...

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Tips: Air Ducts | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

the walls, floors, and ceilings; it carries the air from your home's furnace and central air conditioner to each room. Ducts are made of sheet metal, fiberglass, or other...

202

NO2 Aging and Iodine Loading of Silver-Functionalized Aerogels  

SciTech Connect (OSTI)

Off-gas treatment systems in used fuel reprocessing which use fixed-bed adsorbers are typically designed to operate for an extended period of time before replacement or regeneration of the adsorbent. During this time, the sorbent material will be exposed to the off-gas stream. Exposure could last for months, depending on the replacement cycle time. The gas stream will be at elevated temperature and will possibly contain a mixture of water vapor, NOx, nitric acid vapors, and a variety of other constituents in addition to the radionuclides of capture interest. A series of studies were undertaken to evaluate the effects of long-term exposure, or aging, on proposed iodine sorbent materials under increasingly harsh off-gas conditions. Previous studies have evaluated the effects of up to 6 months of aging under dry air and under humid air conditions on the iodine loading behavior of Ag0-functionalized aerogels. This study examines the effects of extended exposure (up to 6 months) to NO2 on the iodine loading capacity of Ag0- functionalized aerogels. Material aged for 1 and 2 months appeared to have a similar total loading capacity to fresh material. Over an aging period of 4 months, a loss of approximately 15% of the total iodine capacity was seen. The iodine capacity loss on silver-functionalized aerogels due to NO2 was smaller than the iodine capacity loss due to humid or dry air aging.

Patton, K K [ORNL; Bruffey, S H [ORNL; Walker, J F [ORNL; Jubin, R T [ORNL

2014-07-31T23:59:59.000Z

203

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network [OSTI]

Baseline Efficient Air Conditioners . . . . . . 28 AverageEfficient Air Conditioners . . . . . . . . . . . . . . . . .Btu/h Commercial Air Conditioners . . . . . . . . . . . . .

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z

204

Air Pollution Issues of the 1990's  

E-Print Network [OSTI]

of 1990 will contain. However, many political and economic battles remain to be fought. Currently, the Environmental Protection Agency (EPA) estimates that more than $30 billion a year is being spent to control air pollution in this country (1... or simply air toxics. Like ambient ozone nonattainment, air toxics exemplify the pollution problems of the 1990's. Toxic air emissions often occur in tiny amounts compared to criteria pollutants. The causes and effects can vary dramatically from city...

Myers, J. C.

205

Compressed Air Energy Storage for Offshore  

E-Print Network [OSTI]

transmitting peak power levels. A solution to these issues is a novel high-efficiency compressed air energy

Perry Y. Li; Eric Loth; Terrence W. Simon; James D. Van De Ven; Stephen E. Crane

2011-01-01T23:59:59.000Z

206

FAA Air Traffic Organization Safety Management  

Broader source: Energy.gov [DOE]

Presenter: Mark DeNicuolo, Manager Performance and Analyses Air Traffic Organization Safety and Technical Training Federal Aviation Administration

207

Climate Change, the Clean Air Act, and Industrial Pollution  

E-Print Network [OSTI]

Air Act, and Industrial Pollution Professor Alice Kaswan* I.a. Existing Air Pollution. . b. Do Climate Policieson Cli- mate Change, Pollution, and the Clean Air Act." I

Kaswan, Alice

2012-01-01T23:59:59.000Z

208

air bag parameter: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

air temperatures... conditions. The design of this study was based on the relation- ship of four parameters: air temperature, air velocity, radiant heat, and globe...

209

Air movement as an energy efficient means toward occupant comfort  

E-Print Network [OSTI]

M. and E. Arens E. 1993. Air movement and thermal comfort.1994. Locally controlled air movement preferred in warmR, Bittencourt L. 2010. Air movement acceptability limits

Arens, Edward; Zhang, Hui; Pasut, Wilmer; Zhai, Yongchao; Hoyt, Tyler; Huang, Li

2013-01-01T23:59:59.000Z

210

Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems  

E-Print Network [OSTI]

In Review J. Indoor Air) 2007 LBNL-63193 Tarantola, Albert,Gas Measurement to Determine Air Movements in a House,Measurement Techniques, Air Infiltration and Ventilation

Sherman, Max H.

2008-01-01T23:59:59.000Z

211

Combustion Air Zone (CAZ) Best Practices | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Combustion Air Zone (CAZ) Best Practices Combustion Air Zone (CAZ) Best Practices Combustion Air Zone (CAZ) Best Practices Webinar. Presentation More Documents & Publications...

212

Cold Air Distribution in Office Buildings: Technology Assessment for California  

E-Print Network [OSTI]

Field Evaluation of Cold Air Distribution Systems. EPRIand J.S. Elleson. 1988. Cold Air Distribution Design Guide.Field Evaluation of a Cold Air Distribution System. EPRI

Bauman, F.S.

2008-01-01T23:59:59.000Z

213

V-090: Adobe Flash Player / AIR Multiple Vulnerabilities | Department...  

Broader source: Energy.gov (indexed) [DOE]

0: Adobe Flash Player AIR Multiple Vulnerabilities V-090: Adobe Flash Player AIR Multiple Vulnerabilities February 13, 2013 - 12:14am Addthis PROBLEM: Adobe Flash Player AIR...

214

Local air pollutants threaten Lake Tahoes clarity  

E-Print Network [OSTI]

AS (eds. ). Effects of Air Pollution on Western Forests.Air Waste Management Assoc, Transactions Ser No 16, p 279-and support. (California Air Resources Board) for their

2006-01-01T23:59:59.000Z

215

HVAC Cabinet Air Leakage Test Method - Building America Top Innovation...  

Energy Savers [EERE]

their air sealing practices to reduce the amount of air leaking at ducts and duct boots, testing showed that distribution systems still leaked at air handlers and furnace...

216

High-Efficiency Window Air Conditioners - Building America Top...  

Broader source: Energy.gov (indexed) [DOE]

Window Air Conditioners - Building America Top Innovation This photo shows a window air conditioning unit in place in a window frame. Window air conditioners are inexpensive,...

217

Making Li-air batteries rechargeable: material challenges. |...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Li-air batteries rechargeable: material challenges. Making Li-air batteries rechargeable: material challenges. Abstract: A Li-air battery could potentially provide three to five...

218

Health effects of air pollution: some historical notes.  

E-Print Network [OSTI]

that was his first air pollution health effects committeeand direction of air pollution health effects research inof community air pollution, including health ef- fects, has

Whittenberger, J L

1989-01-01T23:59:59.000Z

219

Assessments of biofuel sustainability: air pollution and health impacts  

E-Print Network [OSTI]

Sustainability: Air Pollution and Health Impacts By Chi-and indirect air-pollution and health impacts throughout theparticularly air pollution and health impacts. In this

Tsao, Chi-Chung

2012-01-01T23:59:59.000Z

220

A comparison between two underfloor air distribution (UFAD) design tools  

E-Print Network [OSTI]

TWO UNDERFLOOR AIR DISTRIBUTION (UFAD) DESIGN TOOLS Bin CHENunderfloor air distribution (UFAD) design tools (ASHRAE RP-air distribution (UFAD), Cooling load, Design tool, HVAC

Chen, Bin; Schiavon, Stefano; Bauman, Fred S; Chen, Qingyan

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

ambient air samples: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

ambient air. A small amount of these nuclei mode particles contain solid ash from lube oil) South Coast Air Quality Management District California Air Resources Board Cummins...

222

air heaters: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

meteorological fields Aerosol Emissions; Northern Hemispheric 152 Compressed Air Energy Savings: SAV-AIR Monitor and Control System and the PNW Compressed Air Challenge...

223

air distribution system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

by bringingArnold Schwarzenegger Governor AIR QUALITY IMPACTS OF DISTRIBUTED GENERATION IN THE SOUTH COAST AIR Board, South Coast Air Quality Management District, and San...

224

air distribution systems: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

by bringingArnold Schwarzenegger Governor AIR QUALITY IMPACTS OF DISTRIBUTED GENERATION IN THE SOUTH COAST AIR Board, South Coast Air Quality Management District, and San...

225

Determining benefits and costs of improved central air conditioner efficiencies  

E-Print Network [OSTI]

Products: Central Air Conditioners and Heat Pumps Energyof Improved Central Air Conditioner Efficiencies Authorsresidential-type central air conditioner energy-efficiency

Rosenquist, G.

2010-01-01T23:59:59.000Z

226

Dirty air conditioners: Energy implications of coil fouling  

E-Print Network [OSTI]

1473. Neal, L. 1992. Air Conditioner Efficiency in the Realof a Residential Air Conditioner. Proceedings of the 1992of new residential air conditioners in Phoenix, Arizona.

Siegel, Jeffrey; Walker, Iain; Sherman, Max

2002-01-01T23:59:59.000Z

227

Strategy Guideline: Compact Air Distribution Systems  

SciTech Connect (OSTI)

This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

Burdick, A.

2013-06-01T23:59:59.000Z

228

Air Pollution, ATS555 Colorado State University  

E-Print Network [OSTI]

Air Pollution, ATS555 Colorado State University Fall 2014 Mondays and Wednesdays @ 4:00 ­ 5:30 Room://ramct.colostate.edu/) Textbooks: Air Pollution: Its Origin and Control, 3rd Edition, by Wark, Warner and Davis, Addison Wesley. Specific objectives include: 1. Develop an understanding of types and sources of air pollution. 2. Examine

Collett Jr., Jeffrey L.

229

Scottish Air Pollution and Health Workshop  

E-Print Network [OSTI]

Scottish Air Pollution and Health Workshop Session 4 Joint Research Policy Needs and Interactions needs and how can we work together effectively on these to reduce the adverse effects of air pollution together effectively on these to reduce the adverse effects of air pollution in Scotland. Modelling

230

AIR CONDITIONER REQUEST EXTREME MEDICAL CIRCUMSTANCES  

E-Print Network [OSTI]

AIR CONDITIONER REQUEST DUE TO EXTREME MEDICAL CIRCUMSTANCES TO BE COMPLETED BY ATTENDING Moderate Significant Is the use of an air conditioner desirable Yes No OR essential Yes No to the management of allergy? Is the use of an air conditioner

231

Air Distribution Effectiveness for Different Mechanical Ventilation  

E-Print Network [OSTI]

LBNL-62700 Air Distribution Effectiveness for Different Mechanical Ventilation Systems Max H Orlando Lawrence Berkeley National Laboratory is an equal opportunity employer. #12;1 Air Distribution depending on the effectiveness of their air distribution systems and the location of sources and occupants

232

Air Gap Tunin Yilin Mao, Yashwanth  

E-Print Network [OSTI]

Air Gap Tunin Yilin Mao, Yashwanth Electrical Engineering Departm The Unive ymao1@olemiss.edu, ypadooru@ Abstract-- An adjustable air gap was proposed the resonant frequency of patch antennas the frequency of coaxially fed p center conductor has to be de-soldered and r time the width of the air gap

Elsherbeni, Atef Z.

233

Iron Air collision with high density QCD  

E-Print Network [OSTI]

The color glass condensate approach describes successfully heavy ion collisions at RHIC. We investigate Iron-air collisions within this approach and compare results to event generators commonly used in air shower simulations. We estimate uncertainties in the extrapolation to GZK energies and discuss implications for air shower simulations.

Hans-Joachim Drescher

2006-12-08T23:59:59.000Z

234

Air Pollutant Data for Linking Studies  

E-Print Network [OSTI]

Air Pollutant Data for Linking Studies New Jersey Department of Health and Senior Services #12;New Jersey Close-up View View from Space #12;Air Pollutant/Health Linking Studies in New Jersey · CDC 03074 ­ Air toxics (carcinogens) in relation to: · incidence of selected cancers · prevalence of selected

235

NOAA Air Resources Laboratory Quarterly Activity Report  

E-Print Network [OSTI]

and Hawaii Meteorological Grids for NCEP Atmospheric Turbulence and Diffusion Division 18. Climate 19. Air for Europe convention on Long-Range Transport of Air Pollution. o.russell.bullock@noaa.gov 3. CarbonNOAA Air Resources Laboratory Quarterly Activity Report (January ­ March 2008) Contents Highlights

236

Leviathan and the Air-Pump: Hobbes,  

E-Print Network [OSTI]

Leviathan and the Air-Pump: Hobbes, Boyle, and the Experimental Life Steven Shapin and Simon, Robert Boyle built an air-pump to do exper- iments. Does the story of Roundheads and Restor- ation have on the debates between Boyle and his archcritic Thomas Hobbes over the air-pump, the authors proposed

Landweber, Laura

237

Analysis of Water Modeling of Air Entrainment  

E-Print Network [OSTI]

Analysis of Water Modeling of Air Entrainment S.C. Jain Professor and Research Engineer Dept. Civil, C., "Analysis of Water Modeling of Air Entrainment," in Proceedings of the 48th SFSA Technical An analysis is reported of the water modeling experiments of Bates et al. (1994) to study air entrainment

Beckermann, Christoph

238

Air Chemistry and Pollution Spring 2014  

E-Print Network [OSTI]

ATOC 3500 Air Chemistry and Pollution Spring 2014 Meeting: T/Th, 12:30 ­ 1:45 am; Duane G1B25 in the news; for example, the quality of the air we breathe directly affects our health. In addition to mitigate the effects of air pollution. Finally, we examine some recent examples of atmospheric chemical

Toohey, Darin W.

239

Capturing CO2 from Air Anca Timofte  

E-Print Network [OSTI]

Capturing CO2 from Air Anca Timofte Climeworks AG Birchstrasse 155, 8050 Zürich www.climeworks.com, contact@climeworks.com Carbon Mitigation Lecture, 27 October 2014 #12;Air Climeworks CO2 capture plant CO2-free air Pure CO2 #12;3 Climeworks Products Demonstrator · 1 ton CO2 per year · Online since 12

Fischlin, Andreas

240

Air Potato Management in Your Backyard  

E-Print Network [OSTI]

Air Potato Management in Your Backyard Ridding your property of air potatoes is no easy task - Collect air potatoes that have fallen to the ground. They may still be attached to dead vines, so pulling the vines down could result in more potatoes falling. SPRING - Look for newly sprouting vines and follow

US Army Corps of Engineers

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

3, 35433588, 2003 3-D air pollution  

E-Print Network [OSTI]

ACPD 3, 3543­3588, 2003 3-D air pollution modelling L. M. Frohn et al. Title Page Abstract hemispheric nested air pollution model L. M. Frohn, J. H. Christensen, J. Brandt, C. Geels, and K. M. Hansen 2003 Correspondence to: L. M. Frohn (lmf@dmu.dk) 3543 #12;ACPD 3, 3543­3588, 2003 3-D air pollution

Boyer, Edmond

242

Air Quality Standards & ATOC/CHEM 5151  

E-Print Network [OSTI]

1 Lecture 22 Air Quality Standards & Control ATOC/CHEM 5151 #12;2 Primary Pollutants Things to reduce air pollution emissions ­ Latest version ­ 1990 (original, 1963) ­ What is an "air pollutant that are directly emitted Nitrogen Oxides (NOx) Hydrocarbons (VOCs) Carbon Monoxide (CO) #12;3 Secondary Pollutants

Toohey, Darin W.

243

Physiological responses to air pollutants G. Halbwachs  

E-Print Network [OSTI]

Physiological responses to air pollutants G. Halbwachs Zentrum fur Umwelt- und Naturschutz of fumigation experiments on young plants could be utilized for inter- preting some effects when air pollution of the interaction between air pollution and the forest ecosystem, where not only emission stress is at hand

Boyer, Edmond

244

Workshop on indoor air quality research needs  

SciTech Connect (OSTI)

Workshop participants report on indoor air quality research needs including the monitoring of indoor air quality, report of the instrumentation subgroup of indoor air quality, health effects, and the report of the control technology session. Risk analysis studies addressing indoor environments were also summarized. (DLS)

Not Available

1980-01-01T23:59:59.000Z

245

Dynamic air deposited coatings for power and black liquor recovery boilers  

SciTech Connect (OSTI)

Dynamic Air Deposition (DyAir) is a novel coating method designed to protect the tubing of power and black liquor recovery boilers against corrosion attack at elevated temperatures. The method utilizes the energy of combustion of gaseous fuel and air to heat the powder material to a temperature just below its melting point and accelerate it over 600 m/s to form a coating. The Ni-Cr and Ni-Cr-Mo DyAir coatings revealed no gas permeability and extremely low oxygen content. Compared to the electric arc and HVOF-sprayed coatings, the DyAir coatings exhibited higher hardness and better crack resistance. During aging at 400 and 700 C the bond strength and crack resistance of the DyAir coatings increased dramatically due to intensive diffusion processes in absence of internal corrosion attack. The DyAir coatings revealed outstanding resistance to corrosion, such as sulfidation attack in presence of hydrochloric acid gas at 400 C, oxidation attack at 700 C and oxidation attack in presence of chlorine at 400 C.

Verstak, A.A.; Baranovski, V.E. [Advanced Surface Technologies Inc., Richmond, VA (United States)

1999-11-01T23:59:59.000Z

246

Clean Air Act. Revision 5  

SciTech Connect (OSTI)

This Reference Book contains a current copy of the Clean Air Act, as amended, and those regulations that implement the statute and appear to be most relevant to DOE activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. This Reference Book has been completely revised and is current through February 15, 1994.

Not Available

1994-02-15T23:59:59.000Z

247

Air Conditioner Compressor Performance Model  

SciTech Connect (OSTI)

During the past three years, the Western Electricity Coordinating Council (WECC) Load Modeling Task Force (LMTF) has led the effort to develop the new modeling approach. As part of this effort, the Bonneville Power Administration (BPA), Southern California Edison (SCE), and Electric Power Research Institute (EPRI) Solutions tested 27 residential air-conditioning units to assess their response to delayed voltage recovery transients. After completing these tests, different modeling approaches were proposed, among them a performance modeling approach that proved to be one of the three favored for its simplicity and ability to recreate different SVR events satisfactorily. Funded by the California Energy Commission (CEC) under its load modeling project, researchers at Pacific Northwest National Laboratory (PNNL) led the follow-on task to analyze the motor testing data to derive the parameters needed to develop a performance models for the single-phase air-conditioning (SPAC) unit. To derive the performance model, PNNL researchers first used the motor voltage and frequency ramping test data to obtain the real (P) and reactive (Q) power versus voltage (V) and frequency (f) curves. Then, curve fitting was used to develop the P-V, Q-V, P-f, and Q-f relationships for motor running and stalling states. The resulting performance model ignores the dynamic response of the air-conditioning motor. Because the inertia of the air-conditioning motor is very small (H<0.05), the motor reaches from one steady state to another in a few cycles. So, the performance model is a fair representation of the motor behaviors in both running and stalling states.

Lu, Ning; Xie, YuLong; Huang, Zhenyu

2008-09-05T23:59:59.000Z

248

Air Conditioning | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels DataCombinedDepartment2015Services » Advanced ResearchBusinessAConditioning Air

249

Compressed air | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentratingRenewable Solutions LLC Jump to: navigation,Area (Keith, Et Al., 1992) |1988) |air Jump

250

THE AGE OF PLASTIC INGENUITY + RESPONSIBILITY  

E-Print Network [OSTI]

THE AGE OF PLASTIC INGENUITY + RESPONSIBILITY An Interdisciplinary Symposium Stone Age, Bronze Age, Iron Age...and now the Age of Plastic. The Smithsonian Institution is leveraging its collections--arguably the world's greatest repository of plastic material culture--to investigate the significance of plastic, its

Mathis, Wayne N.

251

Ethylenediamine at Air/Liquid and Air/Silica Interfaces: Protonation  

E-Print Network [OSTI]

surface and EDA protonated products at air/liquid interfaces. The SFG spectra of EDA adsorbedEthylenediamine at Air/Liquid and Air/Silica Interfaces: Protonation Versus Hydrogen BondingKa (HOSit)) is between the two pKa values of EDA (in the range of 7.56-10.71) at the air/silica interface

252

THE PREV AIR SYSTEM, AN OPERATIONAL SYSTEM FOR LARGE SCALE AIR QUALITY FORECASTS OVER EUROPE; APPLICATIONS  

E-Print Network [OSTI]

THE PREV AIR SYSTEM, AN OPERATIONAL SYSTEM FOR LARGE SCALE AIR QUALITY FORECASTS OVER EUROPE Author ABSTRACT Since Summer 2003, the PREV'AIR system has been delivering through the Internet1 daily air quality forecasts over Europe. This is the visible part of a wider collaborative project

Paris-Sud XI, Université de

253

Air Force Research Laboratory Placement: Air Force Research Laboratory, Materials and Manufacturing Directorate, Wright-Patterson  

E-Print Network [OSTI]

Air Force Research Laboratory Placement: Air Force Research Laboratory, Materials and Manufacturing Directorate, Wright-Patterson Air Force Base, Dayton OH Discipline(s): Materials science/engineering, chemical. Description: We are looking for a qualified candidate to join our team at the Air Force Research Laboratory

Alpay, S. Pamir

254

PREV'AIR, a platform for air quality monitoring and fore-, Menut, L.2  

E-Print Network [OSTI]

PREV'AIR, a platform for air quality monitoring and fore- casting Honoré C.1 , Menut, L.2, France 4 ADEME, Paris, France 5 CNRM Meteo-France, Toulouse, France 1 Introduction Since 2003, the PREV'AIR system has been delivering an information about air quality, dedicated to any people or organisation

Menut, Laurent

255

Sensitivity of forced air distribution system efficiency to climate, duct location, air leakage and insulation  

E-Print Network [OSTI]

Location, Air Leakage and Insulation Iain S. Walker Energy4 Duct Insulation, Location and Leakageinsulation

Walker, Iain

2001-01-01T23:59:59.000Z

256

NAQSAT National Air Quality Site Assessment Tool NAQSAT National Air Quality Site Assessment Tool  

E-Print Network [OSTI]

NAQSAT National Air Quality Site Assessment Tool NAQSAT National Air Quality Site Assessment Tool Air Quality Assessment Tool For Livestock Producers & Advisors #12;NAQSAT The National Air Quality Site Assessment Tool (NAQSAT) was developed for livestock producers and their advisors interested

257

Influence of air conditioning management on heat island in Paris air street temperatures  

E-Print Network [OSTI]

Influence of air conditioning management on heat island in Paris air street temperatures Brice 2012 Available online 13 March 2012 Keywords: Air conditioning Heat island mitigation Urban heat island killer'', is exacerbated in urban areas owing to the heat island effect. Air conditioning (A/C) is a key

Ribes, Aurélien

258

Investigation of Feasibility of All-Fresh Air Supply in an All-Air System  

E-Print Network [OSTI]

The feasibility of an all-fresh air supply in an all-air system is investigated in theory, and the problem of AHU-handling air in low efficiency in summer and winter conditions is analyzed. The air supply temperature is almost up to standards when a...

Wang, J.; Yan, Z.

2006-01-01T23:59:59.000Z

259

Air  

E-Print Network [OSTI]

A convenient option is to fly to the Indianapolis International Airport and take a shuttle bus straight to the Purdue Union Hotel. The shuttle departs every two...

260

Ozone induces glucose intolerance and systemic metabolic effects in young and aged brown Norway rats  

SciTech Connect (OSTI)

Air pollutants have been associated with increased diabetes in humans. We hypothesized that ozone would impair glucose homeostasis by altering insulin signaling and/or endoplasmic reticular (ER) stress in young and aged rats. One, 4, 12, and 24 month old Brown Norway (BN) rats were exposed to air or ozone, 0.25 or 1.0 ppm, 6 h/day for 2 days (acute) or 2 d/week for 13 weeks (subchronic). Additionally, 4 month old rats were exposed to air or 1.0 ppm ozone, 6 h/day for 1 or 2 days (time-course). Glucose tolerance tests (GTT) were performed immediately after exposure. Serum and tissue biomarkers were analyzed 18 h after final ozone for acute and subchronic studies, and immediately after each day of exposure in the time-course study. Age-related glucose intolerance and increases in metabolic biomarkers were apparent at baseline. Acute ozone caused hyperglycemia and glucose intolerance in rats of all ages. Ozone-induced glucose intolerance was reduced in rats exposed for 13 weeks. Acute, but not subchronic ozone increased ?{sub 2}-macroglobulin, adiponectin and osteopontin. Time-course analysis indicated glucose intolerance at days 1 and 2 (2 > 1), and a recovery 18 h post ozone. Leptin increased day 1 and epinephrine at all times after ozone. Ozone tended to decrease phosphorylated insulin receptor substrate-1 in liver and adipose tissues. ER stress appeared to be the consequence of ozone induced acute metabolic impairment since transcriptional markers of ER stress increased only after 2 days of ozone. In conclusion, acute ozone exposure induces marked systemic metabolic impairments in BN rats of all ages, likely through sympathetic stimulation. - Highlights: Air pollutants have been associated with increased diabetes in humans. Acute ozone exposure produces profound metabolic alterations in rats. Age influences metabolic risk factors in aging BN rats. Acute metabolic effects are reversible and repeated exposure reduces these effects. Ozone metabolic effects are only slightly exacerbated in geriatric rats.

Bass, V. [Environmental Public Health Division, National Health and Environmental Effects Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, NC (United States); Gordon, C.J.; Jarema, K.A.; MacPhail, R.C. [Toxicity Assessment Division, National Health and Environmental Effects Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, NC (United States); Cascio, W.E. [Environmental Public Health Division, National Health and Environmental Effects Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, NC (United States); Phillips, P.M. [Toxicity Assessment Division, National Health and Environmental Effects Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, NC (United States); Ledbetter, A.D.; Schladweiler, M.C. [Environmental Public Health Division, National Health and Environmental Effects Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, NC (United States); Andrews, D. [Research Cores Unit, National Health and Environmental Effects Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, NC (United States); Miller, D. [Curriculum in Toxicology, University of North Carolina, Chapel Hill, NC (United States); Doerfler, D.L. [Research Cores Unit, National Health and Environmental Effects Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, NC (United States); Kodavanti, U.P., E-mail: kodavanti.urmila@epa.gov [Environmental Public Health Division, National Health and Environmental Effects Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, NC (United States)

2013-12-15T23:59:59.000Z

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

On-Road Air Quality and the Effect of Partial Recirculation on In-Cabin Air Quality for Vehicles  

E-Print Network [OSTI]

The proposed fractional air recirculation system canThe suggested fractional air recirculation method is away of improving cabin air quality. References [1] U.S. DOT.

Grady, Michael

2013-01-01T23:59:59.000Z

262

Meteorological Effects on Air/Fuel Ratio  

E-Print Network [OSTI]

1. "Temperature Compensat d Air/Fuel Ratio Control on a Recuperated Furnace," by J. L. Ferri. GTE Products Corporation, Towanda, PA, lECTC '83 2. Chemical Engineers Handbook, PerTY and Chilton, 5th ed.., (McGraw Hlln, p. 12-7. 3. "Technology..., E = (100 ... 10) (ill) - 100 = 17.2% excess a . 2 Example 2 A furnace uses recuperators which prehe~t the combustion air to 1200 OF using 30 OF air. WithJlOO OF air, the preheated air temperature will be approxIjrnately 1270 OF, a 70 OF increase...

Ferri, J. L.

1984-01-01T23:59:59.000Z

263

Air Entrainment by Viscous Contact Lines  

E-Print Network [OSTI]

The entrainment of air by advancing contact lines is studied by plunging a solid plate into a very viscous liquid. Above a threshold velocity, we observe the formation of an extended air film, typically 10 microns thick, which subsequently decays into air bubbles. Exploring a large range of viscous liquids, we find an unexpectedly weak dependence of entrainment speed on liquid viscosity, pointing towards a crucial role of the flow inside the air film. This induces a striking asymmetry between wetting and dewetting: while the breakup of the air film strongly resembles the dewetting of a liquid film, the wetting speeds are larger by orders of magnitude.

Marchand, Antonin; Snoeijer, Jacco H; Andreotti, Bruno

2011-01-01T23:59:59.000Z

264

Source- and Age-Resolved Mechanistic Air Quality Models: Model Development and Application in Southeast Texas  

E-Print Network [OSTI]

naphthalene (a), acenaphthene (b), acenaphthylene (c), fluorene (d), and phenanthrene (e) and relevant observation from 2007 to 2010 at DRPK. .............................. 122 Figure 5-5. Model predicted APAH1 and APAH2 concentrations as well as the APAHT... of naphthalene, methylnaphthalene, acenaphthylene, and acenaphthene. They estimated that SOA production from oxidation of PAHs emitted from mobile sources in Houston could account for more than 10% of the SOA formed from emissions from mobile sources...

Zhang, Hongliang

2012-07-16T23:59:59.000Z

265

SciTech Connect: Characterization of Dry-Air Aged Granules of  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administrationcontroller systems controllerAdditiveBetatron Radiation from aBrown

266

PREV'AIR, a modeling platform for the air quality predictability study , C. Honor2  

E-Print Network [OSTI]

PREV'AIR, a modeling platform for the air quality predictability study Menut L.1 , C. Honoré2 , L Ministère de l'écologie et du développement durable, Paris, France This platform is proposed by the PREV'AIR about PREV'AIR ? please send an e-mail to cecile.honore@ineris.fr 1. Introduction Since 2002, the PREV'AIR

Menut, Laurent

267

Alpha-environmental continuous air monitor inlet  

DOE Patents [OSTI]

A wind deceleration and protective shroud that provides representative samples of ambient aerosols to an environmental continuous air monitor (ECAM) has a cylindrical enclosure mounted to an input on the continuous air monitor, the cylindrical enclosure having shrouded nozzles located radially about its periphery. Ambient air flows, often along with rainwater flows into the nozzles in a sampling flow generated by a pump in the continuous air monitor. The sampling flow of air creates a cyclonic flow in the enclosure that flows up through the cylindrical enclosure until the flow of air reaches the top of the cylindrical enclosure and then is directed downward to the continuous air monitor. A sloped platform located inside the cylindrical enclosure supports the nozzles and causes any moisture entering through the nozzle to drain out through the nozzles.

Rodgers, John C. (Santa Fe, NM)

2003-01-01T23:59:59.000Z

268

Industrial Compressed Air System Energy Efficiency Guidebook.  

SciTech Connect (OSTI)

Energy efficient design, operation and maintenance of compressed air systems in industrial plants can provide substantial reductions in electric power and other operational costs. This guidebook will help identify cost effective, energy efficiency opportunities in compressed air system design, re-design, operation and maintenance. The guidebook provides: (1) a broad overview of industrial compressed air systems, (2) methods for estimating compressed air consumption and projected air savings, (3) a description of applicable, generic energy conservation measures, and, (4) a review of some compressed air system demonstration projects that have taken place over the last two years. The primary audience for this guidebook includes plant maintenance supervisors, plant engineers, plant managers and others interested in energy management of industrial compressed air systems.

United States. Bonneville Power Administration.

1993-12-01T23:59:59.000Z

269

Numerical Simulation Study on Transpired Solar Air Collector  

E-Print Network [OSTI]

The unglazed transpired solar air collector is now a well-recognized solar air heater for heating outside air directly. In this article, researchers introduced numerical simulation tools into the solar air collector research area, analyzed...

Wang, C.; Guan, Z.; Zhao, X.; Wang, D.

2006-01-01T23:59:59.000Z

270

Deactivation of Accelerated Engine-Aged and Field-Aged SCR Catalysts...  

Broader source: Energy.gov (indexed) [DOE]

Deactivation of Accelerated Engine-Aged and Field-Aged SCR Catalysts and the Role of the DOC Deactivation of Accelerated Engine-Aged and Field-Aged SCR Catalysts and the Role of...

271

Transportation, Aging and Disposal Canister System Performance...  

Office of Environmental Management (EM)

specifications for selected system components of the Transportation, Aging and Disposal (TAD) canister-based system. Transportation, Aging and Disposal Canister System Performance...

272

DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS  

E-Print Network [OSTI]

DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS K. Dao, M.ABSORPTION AIR CONDITIONERS AND HEAT PUMPS* K. DAO, M.

Dao, K.

2013-01-01T23:59:59.000Z

273

A Compressed Air Reduction Program  

E-Print Network [OSTI]

A COMPRESSED AIR REDUCTION PROGRAM K. Dwight Hawks General Motors Corporation - Ruick-Oldsmobi1e-Cadillac Group Warren, Michigan ABSTRACT The reascn for implementing this program was to assist the plant in Quantifying some of its leaks... in the equipme~t throuqhout the plant and to provide direction as to which leaks are yenerat~ng high uti 1ity costs. The direction is very beneficial in lIlaking maintenance aware of prolill,Pls within equipment .IS \\Iell as notifying them as to whf're thei...

Hawks, K. D.

274

Laser Noise Reduction in Air  

E-Print Network [OSTI]

Fluctuations of the white-light supercontinuum produced by ultrashort laser pulses in selfguided filaments (spatio-temporal solitons) in air are investigated. We demonstrate that correlations exist within the white-light supercontinuum, and that they can be used to significantly reduce the laser intensity noise by filtering the spectrum. More precisely, the fundamental wavelength is anticorrelated with the wings of the continuum, while conjugated wavelength pairs on both sides of the continuum are strongly correlated. Spectral filtering of the continuum reduces the laser intensity noise by 1.2 dB, showing that fluctuations are rejected to the edges of the spectrum.

Pierre Bejot; Jerome Kasparian; Estelle Salmon; Roland Ackermann; Nicolas Gisin; Jean-Pierre Wolf

2006-08-09T23:59:59.000Z

275

Air Cooling | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectricEnergy Information LightningAiken Electric CoopCooling: Air cooling

276

Fatigue and Creep Crack Propagation behaviour of Alloy 617 in the Annealed and Aged Conditions  

SciTech Connect (OSTI)

The crack propagation behaviour of Alloy 617 was studied under various conditions. Elevated temperature fatigue and creep-fatigue crack growth experiments were conducted at 650 and 800 degrees C under constant stress intensity (triangle K) conditions and triangular or trapezoidal waveforms at various frequencies on as-received, aged, and carburized material. Environmental conditions included both laboratory air and characteristic VHTR impure helium. As-received Alloy 617 displayed an increase in the crack growth rate (da/dN) as the frequency was decreased in air which indicated a time-dependent contribution component in fatigue crack propagation. Material aged at 650C did not display any influence on the fatigue crack growth rates nor the increasing trend of crack growth rate with decreasing frequency even though significant microstructural evolution, including y (Ni3Al) after short times, occurred during aging. In contrast, carburized Alloy 617 showed an increase in crack growth rates at all frequencies tested compared to the material in the standard annealed condition. Crack growth studies under quasi-constant K (i.e. creep) conditions were also completed at 650 degrees C and a stress intensity of K = 40 MPa9 (square root)m. The results indicate that crack growth is primarily intergranular and increased creep crack growth rates exist in the impure helium environment when compared to the results in laboratory air. Furthermore, the propagation rates (da/dt) continually increased for the duration of the creep crack growth either due to material aging or evolution of a crack tip creep zone. Finally, fatigue crack propagation tests at 800 degrees C on annealed Alloy 617 indicated that crack propagation rates were higher in air than impure helium at the largest frequencies and lowest stress intensities. The rates in helium, however, eventually surpass the rates in air as the frequency is reduced and the stress intensity is decreased which was not observed at 650 degrees C.

Julian K. Benz; Richard N. Wright

2013-10-01T23:59:59.000Z

277

ment of robust recognition in diverse environmental condi-tions through the formulation of a series of speech enhance  

E-Print Network [OSTI]

of a series of speech enhance Speech Recognition System ment and stress compensationpreprocessingalgorithms iterative speech enhancement [1,2]. Stress compensation al- gorithms are based on formant location, bandwidth, and in- tensity. Enhancement preprocessingincreases recognition by +34% for neutral speech, 18

Texas at Dallas, University of

278

thorie, rnais plutt l'emploi des tubes qui modifient les condi-tions de l'vaporation. E. HAUDI.  

E-Print Network [OSTI]

possible l'effet Peltier ; elles ont conlirm la loi de Thomson. Celles de NI. Jahn, au contraire, duraient loi de Thomson relative l'effet Peltier dans le cas de deux mtaux diffrentes, d'un mtal et d semblable celui qui a t dj dcrit (1 ). Les valeurs moyennes de l'efl'et Peltier, lorsqu'on fait

Paris-Sud XI, Universit de

279

Ambient Operation of Li/Air Batteries  

SciTech Connect (OSTI)

In this work, Li/air batteries based on nonaqueous electrolytes were investigated in ambient conditions (with an oxygen partial pressure of 0.21 atm and relative humidity of ~20%). A heat-sealable polymer membrane was used as both an oxygen-diffusion membrane and as a moisture barrier for Li/air batteries. The membrane also can minimize the evaporation of the electrolyte from the batteries. Li/air batteries with this membrane can operate in ambient conditions for more than one month with a specific energy of 362 Wh kg-1, based on the total weight of the battery including its packaging. Among various carbon sources used in this work, Li/air batteries using Ketjenblack (KB) carbon-based air electrodes exhibited the highest specific energy. However, KB-based air electrodes expanded significantly and absorbed much more electrolyte than electrodes made from other carbon sources. The weight distribution of a typical Li/air battery using the KB-based air electrode was dominated by the electrolyte (~70%). Lithium-metal anodes and KB-carbon anodes account for only 5.12% and 5.78% of the battery weight, respectively. We also found that only ~ 20% of the mesopore volume of the air electrode was occupied by reaction products after discharge. To further improve the specific energy of the Li/air batteries, the microstructure of the carbon electrode needs to be further improved to absorb much less electrolyte while still holding significant amounts of reaction products

Zhang, Jiguang; Wang, Deyu; Xu, Wu; Xiao, Jie; Williford, Ralph E.

2010-07-01T23:59:59.000Z

280

!anspace age esa SP-1150  

E-Print Network [OSTI]

.2 Solar Wind 3.3 Role of Europe 3.4 Conclusions and Recommendations 4. High-Energy Physics 4.8 Role of Europe 5.9 Conclusions and Recommendations 6. Exploitation of the Moon 6.1 Power Generation!anspace age #12;esa SP-1150 June 1992 MISSIONto the MOON Europe's Priorities

Rathbun, Julie A.

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Kentucky Cheese: Coming of Age  

E-Print Network [OSTI]

i The FoodIssue Kentucky Cheese: Coming of Age pg. 7 Kentucky is Apple-icious A Taste for Success and does not imply approval to the exclusion of other suitable products or firms. Kentucky Cheese: Coming, and approved by UK's Food Systems Innovation Center. Kentucky is Apple-icious Let those northern and western

Hayes, Jane E.

282

Compressed Air Energy Savings: SAV-AIR Monitor and Control System and the PNW Compressed Air Challenge  

E-Print Network [OSTI]

Portland, OR Portland, OR ABSTRACT This paper presents the results from two compressed air programs supported by the Northwest Energy Efficiency Alliance (Alliance) over the last five years. In 1997 the Alliance funded the Northwest regional version...Resource Group Portland, OR COMPRESSED A[R CHALLENGE The Compressed Air Challenge (CAC) is a national collaborative that develops and provides resources to educate industrial plant operating staff on ways to increase net profits through compressed air...

Anderson, K. J.; Annen, B.; Scott, S.

283

Air and water cooled modulator  

DOE Patents [OSTI]

A compact high power magnetic compression apparatus and method for delivering high voltage pulses of short duration at a high repetition rate and high peak power output which does not require the use of environmentally unacceptable fluids such as chlorofluorocarbons either as a dielectric or as a coolant, and which discharges very little waste heat into the surrounding air. A first magnetic switch has cooling channels formed therethrough to facilitate the removal of excess heat. The first magnetic switch is mounted on a printed circuit board. A pulse transformer comprised of a plurality of discrete electrically insulated and magnetically coupled units is also mounted on said printed board and is electrically coupled to the first magnetic switch. The pulse transformer also has cooling means attached thereto for removing heat from the pulse transformer. A second magnetic switch also having cooling means for removing excess heat is electrically coupled to the pulse transformer. Thus, the present invention is able to provide high voltage pulses of short duration at a high repetition rate and high peak power output without the use of environmentally unacceptable fluids and without discharging significant waste heat into the surrounding air.

Birx, Daniel L. (Oakley, CA); Arnold, Phillip A. (Livermore, CA); Ball, Don G. (Livermore, CA); Cook, Edward G. (Livermore, CA)

1995-01-01T23:59:59.000Z

284

Air and water cooled modulator  

DOE Patents [OSTI]

A compact high power magnetic compression apparatus and method are disclosed for delivering high voltage pulses of short duration at a high repetition rate and high peak power output which does not require the use of environmentally unacceptable fluids such as chlorofluorocarbons either as a dielectric or as a coolant, and which discharges very little waste heat into the surrounding air. A first magnetic switch has cooling channels formed therethrough to facilitate the removal of excess heat. The first magnetic switch is mounted on a printed circuit board. A pulse transformer comprised of a plurality of discrete electrically insulated and magnetically coupled units is also mounted on said printed board and is electrically coupled to the first magnetic switch. The pulse transformer also has cooling means attached thereto for removing heat from the pulse transformer. A second magnetic switch also having cooling means for removing excess heat is electrically coupled to the pulse transformer. Thus, the present invention is able to provide high voltage pulses of short duration at a high repetition rate and high peak power output without the use of environmentally unacceptable fluids and without discharging significant waste heat into the surrounding air. 9 figs.

Birx, D.L.; Arnold, P.A.; Ball, D.G.; Cook, E.G.

1995-09-05T23:59:59.000Z

285

Room air monitor for radioactive aerosols  

DOE Patents [OSTI]

A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-preamplifier combination. 2 figs.

Balmer, D.K.; Tyree, W.H.

1987-03-23T23:59:59.000Z

286

Stirling Air Conditioner for Compact Cooling  

SciTech Connect (OSTI)

BEETIT Project: Infinia is developing a compact air conditioner that uses an unconventional high efficient Stirling cycle system (vs. conventional vapor compression systems) to produce cool air that is energy efficient and does not rely on polluting refrigerants. The Stirling cycle system is a type of air conditioning system that uses a motor with a piston to remove heat to the outside atmosphere using a gas refrigerant. To date, Stirling systems have been expensive and have not had the right kind of heat exchanger to help cool air efficiently. Infinia is using chip cooling technology from the computer industry to make improvements to the heat exchanger and improve system performance. Infinias air conditioner uses helium gas as refrigerant, an environmentally benign gas that does not react with other chemicals and does not burn. Infinias improvements to the Stirling cycle system will enable the cost-effective mass production of high-efficiency air conditioners that use no polluting refrigerants.

None

2010-09-01T23:59:59.000Z

287

June 17, 2013 Symposium on Aging  

E-Print Network [OSTI]

to forestall and treat diseases of aging such as diabetes, cancer, Alzheimer's and heart disease. Today

Church, George M.

288

Alternatives to Electric Air Conditioning Systems  

E-Print Network [OSTI]

, and exposed to a purge air stream to remove the moisture. The drier air eliminates the need for low evaporator temperatures, allowing the compressor to operate more efficiently, providing only sensible cooling. The synergy of the desiccant/engine chiller... during the summer, including solar gain and high ambient temperatures, the air conditioning system must also handle the heat generated by lighting, personnel, and office equipment. These internal loads dominate in large buildings, especially where...

Lindsay, B. B.; Koplow, M. D.

1988-01-01T23:59:59.000Z

289

Radionuclide Air Emission Report for 2011  

E-Print Network [OSTI]

470E-201 Radionuclide Air Emission Report for Prepared by:Environmental Protection Agency, National Emission Standardsfor Emissions of Radionuclides Other Than Radon From

Wahl, Linnea

2012-01-01T23:59:59.000Z

290

Liquid phase thermal swing chemical air separation  

DOE Patents [OSTI]

A temperature swing absorption separation of oxygen from air is performed with an oxygen acceptor of alkali metal nitrate and nitrite. 2 figs.

Erickson, D.C.

1988-05-24T23:59:59.000Z

291

Liquid phase thermal swing chemical air separation  

DOE Patents [OSTI]

A temperature swing absorption separation of oxygen from air is performed with an oxygen acceptor of alkali metal nitrate and nitrite.

Erickson, Donald C. (Annapolis, MD)

1988-01-01T23:59:59.000Z

292

Regulations for Air Quality (Quebec, Canada)  

Broader source: Energy.gov [DOE]

This Regulation establishes emission standards for particulates and gases, emission opacity standards, standards of air quality and control measures to prevent, eliminate or reduce the emission of...

293

Effects of air pollution on vascular thrombosis  

E-Print Network [OSTI]

Increases in air pollution, especially the particulate component, are associated with increased cardiovascular mortality, possibly through increases in thrombogenic mechanisms. The research presented in this thesis ...

Tabor, Caroline Mary

2011-07-05T23:59:59.000Z

294

BUILDING VENTILATION AND INDOOR AIR QUALITY  

E-Print Network [OSTI]

monoxide and nitrogen dioxide from gas appliances;health, indoor air quality, nitrogen dioxide, radon The workin residen- (CO), nitrogen dioxide (NOz), formaldehyde (

Hollowell, C.D.

2012-01-01T23:59:59.000Z

295

Ellsworth Air Force Base Advanced Metering Project  

Broader source: Energy.gov [DOE]

Presentation covers the Ellsworth Air Force Base Advanced Metering project and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

296

Energy performance of underfloor air distribution systems  

E-Print Network [OSTI]

UnderfloorAirDistribution(UFAD)DesignGuide. Atlanta:distribution,UFAD,EnergyPlus,EnergyPlus/UFAD,energy modeling,designdesigncalculationsmustaccountforthedistributionof

Bauman, Fred; Webster, Tom; Linden, Paul; Buhl, Fred

2007-01-01T23:59:59.000Z

297

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning...  

Broader source: Energy.gov (indexed) [DOE]

highlighted in the video series. Addthis Related Articles National Renewable Energy Laboratory engineer Eric Kozubal examines a prototype air flow channel of the DEVAP, a...

298

Compressed Air Energy Storage Act (Kansas)  

Broader source: Energy.gov [DOE]

This act lays out regulations for the local authorities related to site selection, design, operation and monitoring for underground storage of compressed air.

299

Indoor Air Quality Observations in Public Schools  

E-Print Network [OSTI]

to the plans design wly airflow was 8,850 ch. 'Ihe kitchen air handler has 1,075 &I -ly air flow. ?he plans shmd a design airflow of 2,700 cfm. Ihe following are abservatians and pmblelr6 which wxe related to the mildew pmblan. . 'Ihe twb chilled water... in Texas schaols will be the indoor envFranment. 5-1s enaxraged to be m aggressive in preventive maintermme and plan for irdaar air quality and energy efficiency in school air- conditianimg retrofits. A cpalitative investigation of problems reported...

McClure, J. D.; Estes, J. M.

1990-01-01T23:59:59.000Z

300

Ambient Air Quality Standards (New Jersey)  

Broader source: Energy.gov [DOE]

This article lists specific standards for ambient air quality standards for particulate matter, sulfur dioxide, carbon monoxide, ozone, lead and nitrogen dioxide.

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Ambient Air Quality Standards (New Mexico)  

Broader source: Energy.gov [DOE]

This regulation establishes ambient air quality standards for the areas of New Mexico under the jurisdiction of the Environmental Improvement Board. The maximum allowable concentrations of total...

302

iccs-air | netl.doe.gov  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Air Products and Chemicals, Inc.: Demonstration of CO2 Capture and Sequestration of Steam Methane Reforming Process Gas Used for Large-Scale Hydrogen Production Allentown,...

303

Air cooling for Vertex Detectors  

E-Print Network [OSTI]

The vertex detectors are crucial detectors for future linear e+e- colliders since they must give the most accurate location of any outgoing charged particles originating from the interaction point. The DEPFET collaboration is developing a new type of pixel sensors which provide very low noise and high spatial resolution. In order to precisely determine the track and vertex positions, multiple scattering in the detector has to be reduced by minimizing the material in the sensors, cooling, and support structures. A new method of cooling by blowing air over the sensors has been developed and tested. It is applied in the design and construction of the Belle-II detector and may be used in the new generation of vertex detectors for linear colliders.

Arantza Oyanguren

2012-02-28T23:59:59.000Z

304

Enclosed rotary disc air pulser  

DOE Patents [OSTI]

An enclosed rotary disc air pulser for use with a solvent extraction pulse olumn includes a housing having inlet, exhaust and pulse leg ports, a shaft mounted in the housing and adapted for axial rotation therein, first and second disc members secured to the shaft within the housing in spaced relation to each other to define a chamber therebetween, the chamber being in communication with the pulse leg port, the first disc member located adjacent the inlet port, the second disc member being located adjacent the exhaust port, each disc member having a milled out portion, the disc members positioned on the shaft so that as the shaft rotates, the milled out portions permit alternative cyclical communication between the inlet port and the chamber and the exhaust port and the chamber.

Olson, A. L. (Idaho Falls, ID); Batcheller, Tom A. (Idaho Falls, ID); Rindfleisch, J. A. (Arco, ID); Morgan, John M. (Arco, ID)

1989-01-01T23:59:59.000Z

305

advancing paternal age: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

In most animals, advancing age is accompanied by the deteriorative process of aging (senescence). Aging is the main cause of severe illness and death in humans aging is...

306

advanced paternal age: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

In most animals, advancing age is accompanied by the deteriorative process of aging (senescence). Aging is the main cause of severe illness and death in humans aging is...

307

Chelation: A Fundamental Mechanism of Action of AGE Inhibitors...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Mechanism of Action of AGE Inhibitors, AGE Breakers, and Other Inhibitors of Diabetes Complications. Chelation: A Fundamental Mechanism of Action of AGE Inhibitors, AGE...

308

Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates  

E-Print Network [OSTI]

An experimental study was conducted to quantify the effect of return air leakage from hot/humid attic spaces on the performance of a residential air conditioner. Tests were conducted in psychrometric facilities where temperatures and humidities...

O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

1996-01-01T23:59:59.000Z

309

Research on Fuzzy Regulation Strategies in the Constant Air Volume Air Conditioning System  

E-Print Network [OSTI]

The energy consumption of the constant air volume (CAV) system largely depends on the regulation strategies. Although some air conditioning systems are equipped with automatic regulation devices, others lack effective regulation strategies. To avoid...

Bai, T.; Zhang, J.; Ning, N.; Tong, K.; Wu, Y.; Wang, H.

2006-01-01T23:59:59.000Z

310

Energy performance of air distribution systems part II: room air stratification full scale testing  

E-Print Network [OSTI]

and are connected to a fan coil unit by flexible ductwork asvariable air volume fan coil units typically used in

Webster, Tom; Lukaschek, Wolfgang; Dickeroff, Darryl; Bauman, Fred

2007-01-01T23:59:59.000Z

311

Indoor Air Quality Poor indoor air quality comes from many sources. It can lead to having  

E-Print Network [OSTI]

Indoor Air Quality Fact Sheet Poor indoor air quality comes from many sources. It can lead Indoor Air Pollutants · Molds · Pollen · Dander from pet fur · Secondhand smoke · Formaldehyde · Carbon monoxide that comes from burning propane, other gases and fuels, and charcoal · Household products

312

Air Pollution: History Air Pollution: Any atmospheric constituent present as a result of  

E-Print Network [OSTI]

Air Pollution: History Air Pollution: Any atmospheric constituent present as a result, or materials. Before 1200 AD · Air pollution results from wood burning, tanning, decaying trash, smelting with carbon PbO + C -> Pb + CO Pollutants Produced: CO, SO2 ·Hong, et al., Greenland ice evidence

Weber, Rodney

313

About Nuccio Heating & Air Headquartered in Tampa, Florida, Nuccio Heating & Air serves  

E-Print Network [OSTI]

­ the majority being highly mobile ­ sell and service heating and air conditioning systems for the company customer service Industry Focus Heating and air conditioning services Size 52 employees Case Study Nuccio Fixing Problems Fast In Florida's competitive air conditioning industry, the differentiator is "speed

Fisher, Kathleen

314

inAir: A Longitudinal study of Indoor Air Quality Measurements and Visualizations  

E-Print Network [OSTI]

pollutants are colorless and odorless, while many activities are inconspicuous and routine. We implemented inAir. Among those, air pollution and its effects on health have been researched extensively over past several decades [13]. In particular, the health effects of air pollution cover a wide variety of respiratory

Mankoff, Jennifer

315

The Chachil Limestone (Pliensbachianeearliest Toarcian) Neuqun Basin, Argentina: UePb age calibration and its significance on the Early Jurassic  

E-Print Network [OSTI]

The Chachil Limestone (Pliensbachianeearliest Toarcian) Neuquén Basin, Argentina: UePb age Geológico Minero Argentino and CONICET, Av. Julio A. Roca 651, 1322 Buenos Aires, Argentina b Physics Geológicas, Universidad Nacional de la Plata, Calle 1 - # 644, 1900 La Plata, Argentina e Volcanic Basin

Mazzini, Adriano

316

Langerhans Lab Protocols Water treatment & aging.docx revised 1/30/13 by JW Page 1 of 1  

E-Print Network [OSTI]

salinity) Marine Mix or Instant Ocean 2. Fill bucket with tap water, to brim. 3. Put air stone and heaterLangerhans Lab Protocols Water treatment & aging.docx revised 1/30/13 by JW Page 1 of 1 Water (if available) into bucket. 4. Let water stand at least 24 hours before use. When the water

Langerhans, Brian

317

Quantifying precipitation suppression due to air Pollution  

E-Print Network [OSTI]

Quantifying precipitation suppression due to air Pollution First author: Amir Givati The Hebrew January 2004 #12;ABSTRACT: Urban and industrial air pollution has been shown qualitatively to suppress of the ratio of hill/coast precipitation during the 20th century in polluted areas in line with the increasing

Li, Zhanqing

318

Adverse Health Effects of Air Pollution  

E-Print Network [OSTI]

Adverse Health Effects of Air Pollution Robert W. Haley, M.D. Professor of Medicine Director, Division of Epidemiology University of Texas Southwestern Medical Center Dallas, Texas ? Texas Medical Association has adopted resolutions... Rice University study of how to maintain energy efficiency while reducing air pollution. ? Supported legislation based on the findings. The Medical Professor Increasingly Concerned ? Asthma ? Emphysema ? Heart Attacks ? Stunted lung...

Haley, R. W.

2011-01-01T23:59:59.000Z

319

Clean Air Act Requirements: Uranium Mill Tailings  

E-Print Network [OSTI]

EPA'S Clean Air Act Requirements: Uranium Mill Tailings Radon Emissions Rulemaking Reid J. Rosnick requirements for operating uranium mill tailings (Subpart W) Status update on Subpart W activities Outreach/Communications #12;3 EPA Regulatory Requirements for Operating Uranium Mill Tailings (Clean Air Act) · 40 CFR 61

320

U.S.Air Force Advanced Power  

E-Print Network [OSTI]

efficiency,improved power distribution,reduced fuel dependency,reduction of noise,heat,and visual signatureU.S.Air Force Advanced Power Technology Office (APTO) U.S.Air Force Advanced Power Technology/Wind Powered Hydrogen Generation for Fuel Cell Applications · Waste-To-Energy APTO/Small Business Innovation

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

PERFORMANCE EFFECTS OF AIR VELOCITY PROFILES IN  

E-Print Network [OSTI]

PERFORMANCE EFFECTS OF AIR VELOCITY PROFILES IN A RESIDENTIAL HEAT PUMP By NATHAN ANDREW WEBER PROFILES IN A RESIDENTIAL HEAT PUMP Thesis Approved: _______________________________________ Thesis Advisor the air speed transducer mount and the Plexiglas model of the heat pump. Ipseng Iu and myself worked side

322

Air Temperature in the Undulator Hall  

SciTech Connect (OSTI)

Various analyses have been performed recently to estimate the performance of the air conditioning (HVAC) system planned for the Undulator Hall. This reports summarizes the results and provides an upgrade plan to be used if new requirements are needed in the future. The estimates predict that with the planned loads the tunnel air temperature will be well within the allowed tolerance during normal operation.

Not Available

2010-12-07T23:59:59.000Z

323

Conserve Energy by Optimizing Air Compressor System  

E-Print Network [OSTI]

is the compressed air plant(s), cating air compressors with one 60-hp and one 30-hp which many times include compressors, ancillary screw compressor; (2) the repiping of the existing equipment, and/or an operating sequence that is screw compressors cooling water...

Williams, V. A.

324

Improved Algal Harvesting Using Suspended Air Flotation  

E-Print Network [OSTI]

, consisting primarily of Chlorella and Scenedesmus, composed approximately 80% of the solids inventory during. Furthermore, use of SAF to harvest commercially grown Chlorella and Scenedesmus may reduce manufacturing costs). KEYWORDS: Suspended air flotation (SAF), dissolved air flotation (DAF), wastewater, algae, Chlorella

Jacobson, Arne

325

Energy Efficiency in Compressed Air Systems  

E-Print Network [OSTI]

Energy use in compressed air systems accounts for typically 10% of the total industrial electricity consumption. It also accounts for close to 99% of the CO2 footprint of an air compressor and approximately 80% of the life cycle costs of a...

Hingorani, A.; Pavlov, A.

2010-01-01T23:59:59.000Z

326

Air Resources Laboratory Publications -FY 06  

E-Print Network [OSTI]

Meeting on Air Pollution Modelling and its Application, May 15-19, Leipzig, Germany. NATO/CCMS, 58 in continental air masses. Chapter 14 in: Dynamics of Mercury Pollution on Regional and Global Scales. N. Pirrone Pollution Modelling and its Application, May 15-19, Leipzig, Germany. NATO/CCMS, 60-61 (2006). Bullock, O

327

Power Characteristics of Industrial Air Compressors  

E-Print Network [OSTI]

and with different loads are discussed as case studies. The case studies illustrate how to identify the type of control, and potential problems such as inadequate compressed air storage, over-sized compressors, and compressed air leaks from the power signatures...

Schmidt, C.; Kissock, K.

328

AT 560 (2 Credits) Air Pollution Measurement  

E-Print Network [OSTI]

AT 560 (2 Credits) Air Pollution Measurement Spring 2013 Instructor: Jeff Collett, 491 Resolution and Student Conduct Services." #12;ATS 560 - Air Pollution Measurement Spring 2013 Schedule Useful. 11, 13 Atmospheric Aero- sols/Sampling Lab #2: Aerosol and trace gas sampling; 5 Feb. 18, 20 Intro

329

6, 1120911246, 2006 Relation of air mass  

E-Print Network [OSTI]

are formed via gas phase condensation, and 11210 #12;ACPD 6, 11209­11246, 2006 Relation of air mass history to nucleation events in Po Valley, Italy, using back trajectories analysis L. Sogacheva 1 , A. Hamed 2 , M. C of air mass to San Pietro Capofiume (SPC) in Po Valley, Italy, by means of back trajectory analysis. Our

Boyer, Edmond

330

Arnold Schwarzenegger INDOOR-OUTDOOR AIR LEAKAGE  

E-Print Network [OSTI]

;#12;Indoor-Outdoor Air Leakage in Apartments and Commercial Buildings Appendix A Air Infiltration Model for Large Buildings Appendix B Analysis of Commercial Building Data Appendix C Commercial Building Data contains data and discussion of the leakage parameter in commercial buildings. The leakage parameter

331

Aging of Pentaerythritol Tetranitrate (PETN)  

SciTech Connect (OSTI)

Pentaerythritol tetranitrate (PETN) is a relatively sensitive explosive used in many electroexplosive devices as well as in medicine. Of primary interest to LLNL is its use in items such as exploding bridgewire (EBW) detonators and exploding bridge foil initiators (EFI). In these devices the crystalline powder is pressed into a granular, low-density compact that can be initiated by an exploding wire or foil. The long-term stability of this pressed compact is of interest to weapon stockpile lifetime prediction studies. Key points about potential aging mechanisms can be summarized as follows: (1) There are a number of factors that can contribute to PETN instability. These include particle size, polymorphic phase transitions, crystal structure, impurities, moisture, occlusions, chemical incompatibility and biological (microorganism) action. of these factors the most important for long-term aging of high surface area powders used in detonators appears to be that of particle size growth. (2) There is a great deal of literature on the thermal degradation kinetics of PETN, unfortunately much of it with little bearing on ambient temperature aging during long-term storage. PETN is very stable with respect to thermal decomposition. Low-temperature thermal studies have not revealed evidence of chemical degradation products in archived PETN. Data extrapolated to 30 C predicts a half-life of 12 million years. (3) Moisture seems to lower the activation energy for and accelerate the decomposition of PETN. (4) External drivers affecting stability include temperature, moisture, radiation fields, and stress, while internal drivers include residual solvents, and impurities. Temperature affects kinetic processes of crystal growth such as adsorption, desorption, and diffusion rates of molecules on the surface of PETN crystals. A low-level radiation field may induce unexpected changes in the chemical makeup of PETN and its homologue impurities. Stress at high pressure points caused by crystalline surface irregularities may cause a decrease in surface area over time due to smoothing of contact points and sintering. PETN has been found to contain a number of impurities, including homologues, pentaerythryl ethers with a mixture of hydroxyl and nitrate functional groups, and organic salts, that can alter its physical and chemical properties. (5) The processes of sublimation/recrystallization and surface diffusion are important processes that can cause changes in PETN crystal morphology, particle size distribution and specific surface area. Sublimation feeds a process called Ostwald ripening, which involves the spontaneous growth of larger crystals from those of smaller size. This process proceeds with age regardless of storage conditions unless the crystals are treated to retard growth. The coarsening mechanisms include Ostwald ripening, 'sintering', and surface diffusion. The latter has not been experimentally observed, but a molecular modeling approach has attempted to investigate this phenomenon theoretically. (6) Threshold test fire, particle size distribution, specific surface area, thermal analysis, chemical analysis, powder compact specific surface area and density are approaches that have been used in the attempt to assess changes attributable to aging of PETN, with varying results. The biggest problem lies in the aging mechanism itself, which likely influences small changes in morphology, both internal and external, and particle size distribution changes on a scale too small to reliably monitor. Other aspects, such as subtle changes in density profiles within pressed powder compacts, may be beyond the capability of current technology to assess. Crystal growth significant enough to affect the PETN particle size distribution is expected to impact detonator performance. (7) Factors relevant to stabilizing particle size growth include crystal morphology, powder surface area and particle size distribution; crystal density and internal defects; and powder compact density and density gradients.

Foltz, M F

2009-04-22T23:59:59.000Z

332

Aging of Iron (Hydr)oxides by Heat Treatment and Effects on Heavy  

E-Print Network [OSTI]

caused some volatilization of heavy metals (most notably, Hg). Leaching with water at pH 9 (L/S 10, 24 hAging of Iron (Hydr)oxides by Heat Treatment and Effects on Heavy Metal Binding M E T T E A . S ? R)oxides are used to remove heavy metals from wastewater and in the treatment of air pollution control residues

Frenkel, Anatoly

333

SNF AGING SYSTEM DESCRIPTION DOCUMENT  

SciTech Connect (OSTI)

The purpose of this system description document (SDD) is to establish requirements that drive the design of the spent nuclear fuel (SNF) aging system and associated bases, which will allow the design effort to proceed. This SDD will be revised at strategic points as the design matures. This SDD identifies the requirements and describes the system design, as it currently exists, with emphasis on attributes of the design provided to meet the requirements. This SDD is an engineering tool for design control; accordingly, the primary audience and users are design engineers. This SDD is part of an iterative design process. It leads the design process with regard to the flow down of upper tier requirements onto the system. Knowledge of these requirements is essential in performing the design process. The SDD follows the design with regard to the description of the system. The description provided in the SDD reflects the current results of the design process. Throughout this SDD, the term aging cask applies to vertical site-specific casks and to horizontal aging modules. The term overpack is a vertical site-specific cask that contains a dual-purpose canister (DPC) or a disposable canister. Functional and operational requirements applicable to this system were obtained from ''Project Functional and Operational Requirements'' (F&OR) (Curry 2004 [DIRS 170557]). Other requirements that support the design process were taken from documents such as ''Project Design Criteria Document'' (PDC) (BSC 2004 [DES 171599]), ''Site Fire Hazards Analyses'' (BSC 2005 [DIRS 172174]), and ''Nuclear Safety Design Bases for License Application'' (BSC 2005 [DIRS 171512]). The documents address requirements in the ''Project Requirements Document'' (PRD) (Canori and Leitner 2003 [DIRS 166275]). This SDD includes several appendices. Appendix A is a Glossary; Appendix B is a list of key system charts, diagrams, drawings, lists and additional supporting information; and Appendix C is a list of procedures that will be used to operate the system.

L.L. Swanson

2005-04-06T23:59:59.000Z

334

Air Quality: Reporting Requirements Department: Chemical and General Safety  

E-Print Network [OSTI]

Air Quality: Reporting Requirements Department: Chemical and General Safety Program: Air Quality Owner: Program Manager Authority: ES&H Manual, Chapter 30, Air Quality1 The air quality program manager requirements. This table summarizes all air quality program elements and reporting requirements. The NESHAPs

Wechsler, Risa H.

335

Air Quality: Asbestos Notification Procedure Department: Chemical and General Safety  

E-Print Network [OSTI]

Air Quality: Asbestos Notification Procedure Department: Chemical and General Safety Program: Air Quality Owner: Program Manager Authority: ES&H Manual, Chapter 30, Air Quality1 The Bay Area Air Quality) and air quality program manager Determine if the project is classified as a demolition or renovation

Wechsler, Risa H.

336

Parallelization of Air Quality Models on Structured Grids Using MPI  

E-Print Network [OSTI]

by the Clean Air Act in the United States. In order to understand air pollution and design e#11;ective control of the greatest concerns is air pollution. Air pollutants a#11;ect human health, the biosphere and damage property. Because of these e#11;ects air pollution is now monitored and regulated worldwide, for example

Sandu, Adrian

337

Air Quality: Acronym List Department: Chemical and General Safety  

E-Print Network [OSTI]

hazard analysis AQPM air quality program manager ARP accidental release prevention ATCM air toxic control Standard NESHAPs National Emissions Standards for Hazardous Air Pollutants NOx oxides of nitrogen NPOC nonAir Quality: Acronym List Department: Chemical and General Safety Program: Air Quality Owner

Wechsler, Risa H.

338

Materials Compatibility and Aging for Flux and Cleaner Combinations.  

SciTech Connect (OSTI)

A materials study of high reliability electronics cleaning is presented here. In Phase 1, mixed type substrates underwent a condensed contaminants application to view a worst- case scenario for unremoved flux with cleaning agent residue for parts in a silicone oil filled environment. In Phase 2, fluxes applied to copper coupons and to printed wiring boards underwent gentle cleaning then accelerated aging in air at 65% humidity and 30 O C. Both sets were aged for 4 weeks. Contaminants were no-clean (ORL0), water soluble (ORH1 liquid and ORH0 paste), and rosin (RMA; ROL0) fluxes. Defluxing agents were water, solvents, and engineered aqueous defluxers. In the first phase, coupons had flux applied and heated, then were placed in vials of oil with a small amount of cleaning agent and additional coupons. In the second phase, pairs of copper coupons and PWB were hand soldered by application of each flux, using tin-lead solder in a strip across the coupon or a set of test components on the PWB. One of each pair was cleaned in each cleaning agent, the first with a typical clean, and the second with a brief clean. Ionic contamination residue was measured before accelerated aging. After aging, substrates were removed and a visual record of coupon damage made, from which a subjective rank was applied for comparison between the various flux and defluxer combinations; more corrosion equated to higher rank. The ORH1 water soluble flux resulted in the highest ranking in both phases, the RMA flux the least. For the first phase, in which flux and defluxer remained on coupons, the aqueous defluxers led to worse corrosion. The vapor phase cleaning agents resulted in the highest ranking in the second phase, in which there was no physical cleaning. Further study of cleaning and rinsing parameters will be required.

Archuleta, Kim; Piatt, Rochelle

2015-01-01T23:59:59.000Z

339

Indoor Air Quality in 24 California Residences Designed as High Performance Green Homes  

E-Print Network [OSTI]

Gas furnace Air-to-air heat pump Gas fireplace (primarywith their air-to-air heat pumps, such as nighttimeSystem Type None Air-to-air heat pump Night ventilative

Less, Brennan

2012-01-01T23:59:59.000Z

340

Dark Energy in the Dark Ages  

E-Print Network [OSTI]

LBNL- 61876 Dark Energy in the Dark Ages Eric V. LinderUniversity of California. Dark Energy in the Dark Ages Eric2008) Non-negligible dark energy density at high redshifts

Linder, Eric V.

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Utah Commission on Aging June 6, 2007  

E-Print Network [OSTI]

Institutions Norma Matheson Chair Anne Peterson University of Utah Mayor JoAnn Seghini Midvale City Sara to the Commission for consideration. Aging SMART: Denise Brooks distributed Aging SMART Sourcebook. Website is up

Tipple, Brett

342

Dry aging beef for the retail channel  

E-Print Network [OSTI]

Koohmaraie, & Goll, 1995). The Z-line is one myofibrillar structure clearly altered by proteases in the postmortem aging of beef (Goll, Otsuka, Nagainis, Shannon, Sathe, & Muguruma, 1983). However, Z-disk degradation does not occur to any significant... and humidity is said to be dry aged. Practically all beef is vacuumed packaged at the packer level. However, many believe 3 that wet aging does not produce the enhanced palatability characteristics associated with dry aged beef. This process can...

Smith, Robert David

2007-09-17T23:59:59.000Z

343

Indoor air movement acceptability and thermal comfort in hot-humid climates  

E-Print Network [OSTI]

Introduction Human perception of air movement depends on airIntroduction Human perception of air movement depends on

Candido, Christhina Maria

2010-01-01T23:59:59.000Z

344

Air-Shower Spectroscopy at horizons  

E-Print Network [OSTI]

Horizontal and Upward air-showers are suppressed by deep atmosphere opacity and by the Earth shadows. In such noise-free horizontal and upward directions rare Ultra High Cosmic rays and rarer neutrino induced air-showers may shine, mostly mediated by resonant PeVs interactions in air or by higher energy Tau Air-showers originated by neutrino tau skimming the Earth. At high altitude (mountains, planes, balloons) the air density is so rarefied that nearly all common air-showers might be observed at their maximal growth at a tuned altitude and directions. The arrival angle samples different distances and the corresponding most probable primary cosmic ray energy. The larger and larger distances (between observer and C.R. interaction) make wider and wider the shower area and it enlarge the probability to be observed (up to three order of magnitude more than vertical showers); the observation of a maximal electromagnetic shower development may amplify the signal by two-three order of magnitude (respect suppressed shower at sea level); the peculiar altitude-angle range may disentangle at best the primary cosmic ray energy and composition. Even from existing mountain observatory the up-going air-showers may trace, above the horizons, PeV-EeV high energy cosmic rays and, below the horizons, PeV-EeV neutrino astronomy: their early signals may be captured in already existing gamma telescopes as Magic at Canarie, while facing the Earth edges during (useless) cloudy nights.

D. Fargion

2005-11-20T23:59:59.000Z

345

Aging assessment of essential HVAC chillers used in nuclear power plants  

SciTech Connect (OSTI)

The Pacific Northwest Laboratory conducted a comprehensive aging assessment of chillers used in the essential safety air-conditioning systems in nuclear power plants (NPPs). The chillers used, and air-conditioning systems served, vary in design from plant to plant. The review of operating experience indicated that chillers experience aging degradation and failures. The primary aging factors of concern for chillers include vibration, excessive temperatures and pressures, thermal cycling, chemical attack, and poor quality cooling water. The evaluation of Licensee Event Reports (LERs) indicated that about 38% of the failures were primarily related to aging, 55% were partially aging related, and 7% of the failures were unassignable. About 25% of the failures were primarily caused by human, design, procedure, and other errors. The large number of errors is probably directly related to the complexity of chillers and their interfacing systems. Nearly all of the LERs were the result of entering plant Technical Specification Limiting Condition for Operation (LCO) that initiated remedial actions like plant shutdown procedures. The trend for chiller-related LERs has stabilized at about 0.13 LERs per plant year since 1988. Carefully following the vendor procedures and monitoring the equipment can help to minimize and/or eliminate most of the premature failures. Recording equipment performance can be useful for trending analysis. Periodic operation for a few hours on a weekly or monthly basis is useful to remove moisture and non-condensable gases that gradually build up inside the chiller. Chiller pressurization kits are available that will help minimize the amount of moisture and air ingress to low-pressure chillers during standby periods. The assessment of service life condition monitoring of chillers indicated there are many simple to sophisticated methods available that can help in chiller surveillance and monitoring.

Blahnik, D.E.; Camp, T.W.

1996-09-01T23:59:59.000Z

346

aged rat erectile: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

98504-3144 An age-length key (ALK) is the tra- ditional method for estimating age-stage length samples for relatively costly age determination (age subsamplel. Age...

347

aged interleukin-18 deficient: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

98504-3144 An age-length key (ALK) is the tra- ditional method for estimating age-stage length samples for relatively costly age determination (age subsamplel. Age...

348

age stratigraphic relationships: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

98504-3144 An age-length key (ALK) is the tra- ditional method for estimating age-stage length samples for relatively costly age determination (age subsamplel. Age...

349

Air Quality Impact of Distributed Generation of Electricity  

E-Print Network [OSTI]

of the near source air quality impact of distributedDabdub, D. , 2003. Urban Air quality impacts of distributedDabdub, D. , 2004. Urban Air quality impacts of distributed

Jing, Qiguo

2011-01-01T23:59:59.000Z

350

Air Force Enhanced Use Lease | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Air Force Enhanced Use Lease Air Force Enhanced Use Lease Presentation-given at the Fall 2012 Federal Utility Partnership Working Group (FUPWG) meeting-discusses the U.S. Air...

351

Roswell International Air Center Airport (ROW) Pavement Condition and Analysis  

E-Print Network [OSTI]

Roswell International Air Center Airport (ROW) Pavement Condition and Analysis Submitted to: Jane M ................................................1. Conditions at Roswell International Air Center (ROW) 4 .................................Figure 1. Geographic Location of Roswell International Air Center (ROW) 4 ..............................Table 1

Cal, Mark P.

352

Air Force Achieves Fuel Efficiency through Industry Best Practices...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Air Force Achieves Fuel Efficiency through Industry Best Practices Air Force Achieves Fuel Efficiency through Industry Best Practices Fact sheet offers an overview of the U.S. Air...

353

INDOOR AIR QUALITY MEASUREMENTS IN ENERGY EFFICIENT BUILDINGS  

E-Print Network [OSTI]

the effect of air pollution on human health, 2) the designgenerated indoor air pollution on human health; and if borneAir Pollution Control Association, Portland, Oregon (June 27-July 1, 1976). vJorld Health

Hollowell, C.D.

2011-01-01T23:59:59.000Z

354

Cold Air Distribution in Office Buildings: Technology Assessment for California  

E-Print Network [OSTI]

1988. Cold Air Distribution Design Guide. EPRI Report EM-match the cold air distribution design, the floor-to-floorinclude cold air distribution in their designs. The projects

Bauman, F.S.

2008-01-01T23:59:59.000Z

355

Cold Air Distribution in Office Buildings: Technology Assessment for California  

E-Print Network [OSTI]

Cold Air Distribution Systems. EPRI Report EM-5447, ElectricAir Distribution Design Guide. EPRI Report EM-5730, ElectricAir Distribution System. EPRI Report CU-6690, Vol. 1 and 2,

Bauman, F.S.

2008-01-01T23:59:59.000Z

356

air bag system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

an advanced gas engine... Lindsay, B. B.; Koplow, M. D. 1988-01-01 46 Compressed Air Energy Savings: SAV-AIR Monitor and Control System and the PNW Compressed Air Challenge...

357

UNITED STATES AIR FORCE OUTSIDE THE NATIONAL CAPITAL REGION  

E-Print Network [OSTI]

program in order to reduce Federal employee's contribution to traffic congestion and air pollutionUNITED STATES AIR FORCE OUTSIDE THE NATIONAL CAPITAL REGION PUBLIC TRANSPORTATION BENEFIT PROGRAM): ____________ City (Residence): __________________________State: _______________ Zip Code: ________________ Air Force

358

Lessons learned in modeling Underfloor Air Distribution system  

E-Print Network [OSTI]

terminal unit (TU) cooling design supply air temperature (due to the low supply airflow at low cooling load conditioncontrol the cooling air flow rate or reheated supply air to

Lee, Kwang Ho; Schiavon, Stefano; Webster, Tom; Bauman, Fred; Feng, Jingjuan; Hoyt, Tyler

2011-01-01T23:59:59.000Z

359

RESIDENTIAL LOCATION CHOICE AND TRAVEL BEHAVIOR: IMPLICATIONS FOR AIR QUALITY  

E-Print Network [OSTI]

RESIDENTIAL LOCATION CHOICE AND TRAVEL BEHAVIOR: IMPLICATIONS FOR AIR QUALITY UC Davis-Caltrans Air control measure. #12;RESIDENTIAL LOCATION CHOICE AND TRAVEL BEHAVIOR: IMPLICATIONS FOR AIR QUALITY.......................................................... 3 2.2 The Role of Residential Location Choice

Levinson, David M.

360

Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners  

E-Print Network [OSTI]

Bridging the Efficiency Gap: Commercial Packaged Rooftop Air Conditioners John Shugars, Consultant ofcommercialpackaged air conditioners, explore the reasons behindthis efficiency gap, and assess opportunities). Although sales of rooftop air conditioners have steadily increased over the past decade, the efficiency

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

DEVELOPMENT OF SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS  

E-Print Network [OSTI]

SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS K.Driven Absorption Air-Conditioner", K. Dao, M. Simmons, R.SOLAR DRIVEN ABSORPTION AIR CONDITIONERS AND HEAT PUMPS* K.

Dao, K.

2013-01-01T23:59:59.000Z

362

Twenty-third DOE/NRC nuclear air cleaning and treatment conference  

SciTech Connect (OSTI)

The Twenty-Third Department of Energy/Nuclear Regulatory Commission (DOE/NRC) nuclear Air-Cleaning and Treatment Conference was held July 25-28, 1994, in Buffalo, New York. The conference was also sponsored by the Harvard Air-Cleaning Laboratory and the Internation Society of Nuclear Air Treatment Technologies, a nonprofit organization founded to promote technology transfer in the nuclear air-cleaning and treatment area. A total of 192 air-cleaning specialists attended the conference. The United States and 11 foreign countries were represented. The specialists are affiliated with all aspects of the nuclear industry, including government agencies, educational institutions, utilities, architect-engineers, equipment suppliers, and consultants. The high level of international interests is evident from the 40% of papers sponsored by foreign interests. More than 20% of the attendees as well as several members of the Program Committee were from outside the United States. Major topics discussed at this conference included nuclear air-cleaning codes and standards, waste disposal, particulate filter developments (including testing and performance under stress and after aging), sampling and monitoring of process and effluent streams, off-gasses from fuel reprocessing, adsorbents and adsorption, accident control and analysis, and revised source terms for power-plant accidents. A highlight of the conference concerned operations a at the DOE facility at West Valley, New York, where construction is under way to solidify radioactive waste. A recurrent theme throughout the sessions was that, in spite of the large number of guidance documents available in the form of regulations, codes, standards, and directives, multiple difficulties arise when all are invoked simultaneously. Gas processing needs, rather than controls for civilian power plants, will provide the principal challenge during the next decade for the air-cleaning specialists of the world. 15 refs.

Bellamy, R.R.; Hayes, J.J.; First, M.W.

1995-01-01T23:59:59.000Z

363

Engine piston having an insulating air gap  

DOE Patents [OSTI]

A piston for an internal combustion engine has an upper crown with a top and a bottom surface, and a lower crown with a top and a bottom surface. The upper crown and the lower crown are fixedly attached to each other using welds, with the bottom surface of the upper crown and the top surface of the lower crown forming a mating surface. The piston also has at least one centrally located air gap formed on the mating surface. The air gap is sealed to prevent substantial airflow into or out of the air gap.

Jarrett, Mark Wayne (Washington, IL); Hunold,Brent Michael (Apex, NC)

2010-02-02T23:59:59.000Z

364

Air blast type coal slurry fuel injector  

DOE Patents [OSTI]

A device to atomize and inject a coal slurry in the combustion chamber of an internal combustion engine, and which eliminates the use of a conventional fuel injection pump/nozzle. The injector involves the use of compressed air to atomize and inject the coal slurry and like fuels. In one embodiment, the breaking and atomization of the fuel is achieved with the help of perforated discs and compressed air. In another embodiment, a cone shaped aspirator is used to achieve the breaking and atomization of the fuel. The compressed air protects critical bearing areas of the injector.

Phatak, Ramkrishna G. (San Antonio, TX)

1986-01-01T23:59:59.000Z

365

Air blast type coal slurry fuel injector  

DOE Patents [OSTI]

A device to atomize and inject a coal slurry in the combustion chamber of an internal combustion engine is disclosed which eliminates the use of a conventional fuel injection pump/nozzle. The injector involves the use of compressed air to atomize and inject the coal slurry and like fuels. In one embodiment, the breaking and atomization of the fuel is achieved with the help of perforated discs and compressed air. In another embodiment, a cone shaped aspirator is used to achieve the breaking and atomization of the fuel. The compressed air protects critical bearing areas of the injector.

Phatak, R.G.

1984-08-31T23:59:59.000Z

366

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network [OSTI]

Blast-Type Air Conditioners and Heat Pump. The correspondingair/air air conditioners and heat pumps. Some improvementsconnected air- conditioner (heat pump) units, household

Zhou, Nan

2010-01-01T23:59:59.000Z

367

E-Print Network 3.0 - air quality levels Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

A Breath of Fresh Air: Improving Air Summary: about unhealthful levels of air pollution. Impact Air quality forecasts and warnings for health... Learn More:...

368

E-Print Network 3.0 - ambient air quality-a Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

EHHE; January 2006 7 Topics Air, Ambient (Outdoor) Air, Indoor Disasters Lead... pollutants in ambient air Hazardous or toxic substances released in ambient air Residence in...

369

E-Print Network 3.0 - ambient air monitoring Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

EHHE; January 2006 7 Topics Air, Ambient (Outdoor) Air, Indoor Disasters Lead... pollutants in ambient air Hazardous or toxic substances released in ambient air Residence in...

370

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers  

E-Print Network [OSTI]

is Just Prior to Cooling Air Entering IT Equipment FigureGadgil, A.J. and Tschudi, W.F. , Air Corrosivity in U.S.Outdoor-Air-Cooled Data Centers is Similar to That in

Coles, Henry C.

2012-01-01T23:59:59.000Z

371

A study of air flow through saturated porous media and its applications to in-situ air sparging  

E-Print Network [OSTI]

The efficiency of an in situ air sparging system is controlled by the extent of contact between injected air and contaminated soil and pore fluid. Characterizing the mechanisms governing air propagation through saturated ...

Marulanda, Catalina, 1971-

2001-01-01T23:59:59.000Z

372

air temperature change: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Index 21 Air temperature regulation by urban trees and green infrastructure Renewable Energy Websites Summary: Air temperature regulation by urban trees and green...

373

STATEMENT OF CONSIDERATIONS REQUEST BY AIR PRODUCTS AND CHEMICALS...  

Broader source: Energy.gov (indexed) [DOE]

in the attached waiver petition and in subsequent discussions with DOE Patent Counsel, Air Products and Chemicals, Inc. (Air Products) has requested an advance waiver of...

374

air force bombers: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Engagement Effectiveness 12;Aircrew at Risk The Value of Range, Payload, Precision, and Stealth Bomb Droppers Air Escort Air Defense Suppression Tankers Total Aircrew At Risk...

375

air quality monitoramento: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

- Substantial emissionNational Air Quality Forecast Capability Ivanka Stajner NOAA NWSOST with contributions from AQAST meeting, College Park, MD June 5, 2013 12;National Air...

376

Typical Problems of AHU and Air Movement in Buildings  

E-Print Network [OSTI]

occupied zones #0;?#0;?#0;?#0;? Wrong Air Handling Process and ControlWrong Air Handling Process and Control #0;?#0;?#0;?#0;? TP4: Dislike fresh air?TP4: Dislike fresh air? #0;?#0;?#0;?#0;? TP5: Reheat of VAVBOX at partial load time in summerTP5: Reheat... of VAVBOX at partial load time in summer #0;?#0;?#0;?#0;? Unexpected Air Movement in BuildingsUnexpected Air Movement in Buildings #0;?#0;?#0;?#0;? TP6: Chimney effect leading to fresh air intake in highTP6: Chimney effect leading to fresh air intake in high...

2006-01-01T23:59:59.000Z

377

Air Cooling Technology for Advanced Power Electronics and Electric...  

Broader source: Energy.gov (indexed) [DOE]

Air Cooling Technology for Advanced Power Electronics and Electric Machines Air Cooling Technology for Advanced Power Electronics and Electric Machines 2009 DOE Hydrogen Program...

378

Novel Application of Air Separation Membranes Reduces NOx Emissions...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Application of Air Separation Membranes Reduces NOx Emissions Technology available for licensing: Selective permeation of gases using an air separation membrane. Can be retrofitted...

379

Clean Air Act General Conformity Requirements and the National...  

Broader source: Energy.gov (indexed) [DOE]

Clean Air Act General Conformity Requirements and the National Environmental Policy Act Process Clean Air Act General Conformity Requirements and the National Environmental Policy...

380

Testimonials - Partnerships in R&D - Air Products and Chemicals...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Air Products and Chemicals Incorporated Testimonials - Partnerships in R&D - Air Products and Chemicals Incorporated Addthis Text Version The words "Office of Energy Efficiency &...

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Evaluation of the Compressed Air Challenge Training Program:...  

Broader source: Energy.gov (indexed) [DOE]

Executive Summary Evaluation of the Compressed Air Challenge Training Program: Executive Summary This is the executive summary of a report on an evaluation of the Compressed Air...

382

Evaluation of the Compressed Air Challenge Training Program:...  

Broader source: Energy.gov (indexed) [DOE]

Final Report Evaluation of the Compressed Air Challenge Training Program: Final Report This is the final report on an evaluation of the Compressed Air Challenge (CAC) training...

383

Comprehensive Energy Program at Patrick Air Force Base Set to...  

Broader source: Energy.gov (indexed) [DOE]

Comprehensive Energy Program at Patrick Air Force Base Set to Exceed Energy Goals Comprehensive Energy Program at Patrick Air Force Base Set to Exceed Energy Goals Fact sheet...

384

Electrolux Gibson Air Conditioner and Equator Clothes Washer...  

Broader source: Energy.gov (indexed) [DOE]

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing...

385

High-Temperature, Air-Cooled Traction Drive Inverter Packaging...  

Broader source: Energy.gov (indexed) [DOE]

High-Temperature, Air-Cooled Traction Drive Inverter Packaging High-Temperature, Air-Cooled Traction Drive Inverter Packaging 2010 DOE Vehicle Technologies and Hydrogen Programs...

386

Hickam Air Force Base Fuel Cell Vehicles: Early Implementation...  

Broader source: Energy.gov (indexed) [DOE]

Hickam Air Force Base Fuel Cell Vehicles: Early Implementation Experience Hickam Air Force Base Fuel Cell Vehicles: Early Implementation Experience This report sumarizes early...

387

Residential Forced Air System Cabinet Leakage and Blower Performance  

E-Print Network [OSTI]

CA. CEC(2008b). ResidentialAlternativeCalculationStandardforAirHandlersinResidentialSpaceConditioningofStandardsOptionsforResidentialAirHandlerFans.

Walker, Iain S.

2010-01-01T23:59:59.000Z

388

Arene Trifluoromethylation: An Effective Strategy to Obtain Air...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Effective Strategy to Obtain Air-Stable nType Organic Semiconductors with Tunable Optoelectronic Arene Trifluoromethylation: An Effective Strategy to Obtain Air-Stable nType...

389

airliner cabin air: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Window Location on a King Air 200 Aircraft:aerosol.atmos.und.edu) Objective A Raytheon Beechcraft King Air 200 aircraft has been used to obtain Condensation Particle...

390

air force aircraft: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Window Location on a King Air 200 Aircraft:aerosol.atmos.und.edu) Objective A Raytheon Beechcraft King Air 200 aircraft has been used to obtain Condensation Particle...

391

Chapter 50 Division for Air Quality: General Administrative Procedures (Kentucky)  

Broader source: Energy.gov [DOE]

Chapter 50 of the Division of Air Quality section within Energy and Environment Cabinet Department For Environmental Protection outlines the general administrative procedures for maintaining air...

392

Air-Conditioning, Heating, and Refrigeration Institute (AHRI...  

Energy Savers [EERE]

Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI These...

393

air change rate: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rydhof 2 Traffic-related air pollution exposures and changes in heart rate variability in Mexico City: A panel study MIT - DSpace Summary: Abstract Background While air pollution...

394

air crew exposure: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

E. 18 Traffic-related air pollution exposures and changes in heart rate variability in Mexico City: A panel study MIT - DSpace Summary: Abstract Background While air pollution...

395

air dispersion model: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

source apportionment studies. In highly polluted cities such as Athens, Los Angeles and Mexico, regional scale air quality models are used to forecast air pollution episodes ...

396

air change rates: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rydhof 2 Traffic-related air pollution exposures and changes in heart rate variability in Mexico City: A panel study MIT - DSpace Summary: Abstract Background While air pollution...

397

air pollution studies: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

14 Traffic-related air pollution exposures and changes in heart rate variability in Mexico City: A panel study MIT - DSpace Summary: Abstract Background While air pollution...

398

air endotoxin exposure: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

E. 17 Traffic-related air pollution exposures and changes in heart rate variability in Mexico City: A panel study MIT - DSpace Summary: Abstract Background While air pollution...

399

Natural Gas Heat Pump and Air Conditioner | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Natural Gas Heat Pump and Air Conditioner Natural Gas Heat Pump and Air Conditioner Lead Performer: Thermolift - Stony Brook, NY Partners: -- New York State Energy Research &...

400

Case Study: Evaluating Liquid versus Air Cooling in the Maui...  

Broader source: Energy.gov (indexed) [DOE]

Case Study: Evaluating Liquid versus Air Cooling in the Maui High Performance Computing Center Case Study: Evaluating Liquid versus Air Cooling in the Maui High Performance...

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Advanced Variable Speed Air-Source Integrated Heat Pump 2013...  

Energy Savers [EERE]

Advanced Variable Speed Air-Source Integrated Heat Pump 2013 Peer Review Advanced Variable Speed Air-Source Integrated Heat Pump 2013 Peer Review Emerging Technologies Project for...

402

Global climate change will affect air, water in California  

E-Print Network [OSTI]

Department of Land, Air and Water Resources, UC Davis. Hechange will affect air, water in California Bryan C. Wearelikely to include reduced water availability and quality,

Weare, Bryan C.

2002-01-01T23:59:59.000Z

403

Air Emissions Operating Permit Regulations for the Purposes of...  

Broader source: Energy.gov (indexed) [DOE]

Regulations Provider Department of Environmental Quality The Air Emissions Operating Permit Regulations for the Purpose of Title V of the Federal Clean Air Act make the state...

404

Indoor airPLUS Construction Specifications Version 1 (Rev. 02...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Specifications Version 1 (Rev. 02) Indoor airPLUS Construction Specifications Version 1 (Rev. 02) Indoor airPLUS Construction Specifications Version 1 (Rev. 02), November 2013,...

405

air conditionne point: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

the air quality. Trade off between high purchase price of refrigerated air dryer versus energy savings should also be evaluated. 2. Operational issues such as set point of...

406

Commonwealth of Virginia, State Air Pollution Control Board,...  

Broader source: Energy.gov (indexed) [DOE]

Commonwealth of Virginia, State Air Pollution Control Board, Order by Concent Issued to Mirant Potomac River, LLC, Registration No. 70228 Commonwealth of Virginia, State Air...

407

Knowledge Partnership for Measuring Air Pollution and Greenhouse...  

Open Energy Info (EERE)

Measuring Air Pollution and Greenhouse Gas Emissions in Asia Jump to: navigation, search Name Knowledge Partnership for Measuring Air Pollution and Greenhouse Gas Emissions in Asia...

408

Design, modelling and control of a gas turbine air compressor .  

E-Print Network [OSTI]

??The production of compressed air constitutes a considerable portion of industrial electrical consumption. An alternative to electrically driven air compression systems is a gas turbine (more)

WIESE, ASHLEY PETER

2014-01-01T23:59:59.000Z

409

Hierarchically Porous Graphene as a Lithium-Air Battery Electrode...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Hierarchically Porous Graphene as a Lithium-Air Battery Electrode. Hierarchically Porous Graphene as a Lithium-Air Battery Electrode. Abstract: Functionalized graphene sheets (FGS)...

410

Quantifying the Air Pollution Exposure Consequences of Distributed Electricity Generation  

E-Print Network [OSTI]

species) control technology criteria pollutant air pollutantControl Cogen Urban Santa Maria Elevated Data sources: Emissions: 1999 National Emissions Inventory for Hazardous Air Pollutants (

Heath, Garvin A.; Granvold, Patrick W.; Hoats, Abigail S.; Nazaroff, William W

2005-01-01T23:59:59.000Z

411

New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy  

E-Print Network [OSTI]

1) indoor pollutant source control, and 2) air cleaning.control is complicated by the large number and changing nature of indoor pollutant sources. Particle air

Sidheswaran, Meera

2010-01-01T23:59:59.000Z

412

Thermal Bypass Air Barriers in the 2009 International Energy...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Thermal Bypass Air Barriers in the 2009 International Energy Conservation Code - Building America Top Innovation Thermal Bypass Air Barriers in the 2009 International Energy...

413

air pollutants neshaps: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

mills licensed and regulated by the U.S. Nuclear Regulatory 2 Environmental Pollution Air Pollution Dispersion Practical Air Pollution Dispersion Geosciences Websites Summary:...

414

air pollutants neshap: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

mills licensed and regulated by the U.S. Nuclear Regulatory 2 Environmental Pollution Air Pollution Dispersion Practical Air Pollution Dispersion Geosciences Websites Summary:...

415

air pollution sources: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

reference outlines major categories of air pollutants found at SLAC Wechsler, Risa H. 2 Air pollution sources apportionment in a French urban site Marie Chavent* Physics Websites...

416

Iron-air battery development program  

SciTech Connect (OSTI)

The progress and status of the research and development program on the iron-air advanced technology battery system at the Westinghouse Electric Corporation during the period June 1978-December 1979 are described. This advanced battery system is being developed for electric vehicle propulsion applications. Testing and evaluation of 100 cm/sup 2/ size cells was undertaken while individual iron and air electrode programs continued. Progress is reported in a number of these study areas. Results of the improvements made in the utilization of the iron electrode active material coupled with manufacturing and processing studies related to improved air electrodes continue to indicate that a fully developed iron-air battery system will be capable of fulfilling the performance requirements for commuter electric vehicles.

Buzzelli, E.S.; Liu, C.T.; Bryant, W.A.

1980-05-01T23:59:59.000Z

417

Covered Product Category: Residential Central Air Conditioners...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

operate on single-phase current and have cooling capacities less than 65,000 Btuh. Room air conditioners (window and through-the-wall) are covered by a separate specification,...

418

Geothermal Power Plants Meeting Clean Air Standards  

Broader source: Energy.gov [DOE]

Geothermal power plants can meet the most stringent clean air standards. They emit little carbon dioxide, very low amounts of sulfur dioxide, and no nitrogen oxides. See Charts 1, 2, and 3 below.

419

Air separation with temperature and pressure swing  

DOE Patents [OSTI]

A chemical absorbent air separation process is set forth which uses a temperature swing absorption-desorption cycle in combination with a pressure swing wherein the pressure is elevated in the desorption stage of the process.

Cassano, Anthony A. (Allentown, PA)

1986-01-01T23:59:59.000Z

420

Effects of Air Pollution Control on Climate  

E-Print Network [OSTI]

Urban air pollution and climate are closely connected due to shared generating processes (e.g., combustion) for emissions of the driving gases and aerosols. They are also connected because the atmospheric lifecycles of ...

Prinn, Ronald G.

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Health Damages from Air Pollution in China  

E-Print Network [OSTI]

In China, elevated levels of urban air pollution result in substantial adverse health impacts for its large and rapidly growing urban population. An expanded version of the Emissions Prediction and Policy Analysis (EPPA), ...

Matus, Kira

422

Hybrid air foil bearing with external pressurization  

E-Print Network [OSTI]

used in applications including turbo generators, aircraft air cycle machines[1], automobiles, fuel cell micro-gas turbine(MGT) hybrid systems[2], turbochargers and turbo compressors, etc. One of the critical technical issues related to reliability...

Park, Soongook

2009-05-15T23:59:59.000Z

423

IntegratedScienceWorkingforYou Air, Water,  

E-Print Network [OSTI]

IntegratedScienceWorkingforYou Air, Water, and Aquatic Environments Fire, Fuel, and Smoke Forest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Montana ecosystem restoration treatments . . . . .4 RPA Assessment: U .S . water supply shortage . . .4 Aviationpersonnelexposuretowildfirerisk . . . .5

424

Air leakage of Insulated Concrete Form houses  

E-Print Network [OSTI]

Air leakage has been shown to increase building energy use due to additional heating and cooling loads. Although many construction types have been examined for leakage, an exploration of a large number of Insulated Concrete ...

Durschlag, Hannah (Hanna Rebekah)

2012-01-01T23:59:59.000Z

425

COMBUSTION-GENERATED INDOOR AIR POLLUTION  

E-Print Network [OSTI]

standard I[ o Fig. 2. Nitrogen dioxide concentrations in aCritical Analysis of Nitrogen Dioxide Air Quality Standards,with gas appliances. Nitrogen dioxide levels in kitchens of

Hollowell, C.D.

2011-01-01T23:59:59.000Z

426

A transient-flow syringe air permeameter  

E-Print Network [OSTI]

In response to the need to better describe spatial variations in permeability, we designed and built a new portable field air permeameter for use on rocks in outcrop and core. In this instrument, a chamber containing a ...

Brown, Stephen

427

Compressed Air Load Reduction Approaches and Innovations  

E-Print Network [OSTI]

are assessed. It is a common practice in facilities to simply add compressor capacity when faced with supply pressure or volume deficiencies, increasing the energy consumption associated with compressed air systems in industry. Additionally, in recent years...

D'Antonio, M.; Epstein, G.; Moray, S.; Schmidt, C.

2005-01-01T23:59:59.000Z

428

Khalil Amine on Lithium-air Batteries  

ScienceCinema (OSTI)

Khalil Amine, materials scientist at Argonne National Laboratory, speaks on the new technology Lithium-air batteries, which could potentially increase energy density by 5-10 times over lithium-ion batteries.

Khalil Amine

2010-01-08T23:59:59.000Z

429

ESPC Success Story- Dyess Air Force Base  

Broader source: Energy.gov [DOE]

Fact sheet describes the Federal Energy Management Program (FEMP) Energy Savings Performance Contract (ESPC) Success Story on water conservation and green energy at Dyess Air Foce Base at Dyess, Texas.

430

U.S. Air Force UESCs  

Broader source: Energy.gov [DOE]

Presentationgiven at the Spring 2009 Federal Utility Partnership Working Group (FUPWG) meetingcovers the U.S. Air Force's approval process, submittal requirements, and guidelines for utility energy service contracts (UESCs).

431

Understanding the Basics of Compressed Air Systems  

E-Print Network [OSTI]

, contaminated filters, conversion to electrically operated hoists, and the use of centrifugal fans or compressed air with pressure regulators to purge control cabinets. Finally, a review of compressor technologies with typical cfm, pressure ranges, and price...

Herron, D. J.

432

Economizer Control Using Mixed Air Enthalpy  

E-Print Network [OSTI]

Enthalpy economizer can theoretically save more energy than temperature based economizer. However, the requirement of outdoor air humidity measurement in the traditional enthalpy economizer control made it impossible. A novel control sequence using...

Feng, J.; Liu, M.; Pang, W.

2007-01-01T23:59:59.000Z

433

High-energy metal air batteries  

DOE Patents [OSTI]

Disclosed herein are embodiments of lithium/air batteries and methods of making and using the same. Certain embodiments are pouch-cell batteries encased within an oxygen-permeable membrane packaging material that is less than 2% of the total battery weight. Some embodiments include a hybrid air electrode comprising carbon and an ion insertion material, wherein the mass ratio of ion insertion material to carbon is 0.2 to 0.8. The air electrode may include hydrophobic, porous fibers. In particular embodiments, the air electrode is soaked with an electrolyte comprising one or more solvents including dimethyl ether, and the dimethyl ether subsequently is evacuated from the soaked electrode. In other embodiments, the electrolyte comprises 10-20% crown ether by weight.

Zhang, Ji-Guang; Xiao, Jie; Xu, Wu; Wang, Deyu; Williford, Ralph E.; Liu, Jun

2014-07-01T23:59:59.000Z

434

High-energy metal air batteries  

DOE Patents [OSTI]

Disclosed herein are embodiments of lithium/air batteries and methods of making and using the same. Certain embodiments are pouch-cell batteries encased within an oxygen-permeable membrane packaging material that is less than 2% of the total battery weight. Some embodiments include a hybrid air electrode comprising carbon and an ion insertion material, wherein the mass ratio of ion insertion material to carbon is 0.2 to 0.8. The air electrode may include hydrophobic, porous fibers. In particular embodiments, the air electrode is soaked with an electrolyte comprising one or more solvents including dimethyl ether, and the dimethyl ether subsequently is evacuated from the soaked electrode. In other embodiments, the electrolyte comprises 10-20% crown ether by weight.

Zhang, Ji-Guang; Xiao, Jie; Xu, Wu; Wang, Deyu; Williford, Ralph E.; Liu, Jun

2013-07-09T23:59:59.000Z

435

Michael Thackery on Lithium-air Batteries  

ScienceCinema (OSTI)

Michael Thackery, Distinguished Fellow at Argonne National Laboratory, speaks on the new technology Lithium-air batteries, which could potentially increase energy density by 5-10 times over lithium-ion batteries.

Michael Thackery

2010-01-08T23:59:59.000Z

436

Transient Supersonic Methane-Air Flames  

E-Print Network [OSTI]

The purpose of this study was to investigate the thermochemical properties of a transient supersonic flame. Creation of the transient flame was controlled by pulsing air in 200 millisecond intervals into a combustor filled with flowing methane...

Richards, John L.

2012-07-16T23:59:59.000Z

437

Sponsored by Air Force Research Laboratory  

E-Print Network [OSTI]

Sponsored by Air Force Research Laboratory Space Vehicles Directorate Directed Energy Directorate PROGRAM Space Scholars and Directed Energy Scholars The Space Vehicles and Directed Energy Directorates Scholars The Phillips Scholars internship offers an edu- cational and fulfilling summer job experience

Piao, Daqing

438

COMBUSTION-GENERATED INDOOR AIR POLLUTION  

E-Print Network [OSTI]

x A Emission Characteristics in Two Stage Combustion. PaperInternational) on Combustion, Tokyo (August, 1974). Chang,fll , J I ___F J "J LBL-S9lS COMBUSTION-GENERATED INDOOR AIR

Hollowell, C.D.

2010-01-01T23:59:59.000Z

439

Partitioning Complexity in Air Traffic Management Task  

E-Print Network [OSTI]

Cognitive complexity is a term that appears frequently in air traffic control (ATC) research literature, yet there is little principled investigation of the potential sources of cognitive complexity. Three distinctly ...

Cummings, M. L.

2006-01-01T23:59:59.000Z

440

Large panel design for containment air baffle  

DOE Patents [OSTI]

The movable air baffle shield means in accordance with the present invention provides an efficient method of cooling the space surrounding the containment vessel while also providing the capability of being moved away from the containment vessel during inspection. The containment apparatus comprises a generally cylindrical sealed containment vessel for containing at least a portion of a nuclear power generation plant, a disparate shield building surrounding and housing the containment vessel therein and spaced outwardly thereof so as to form an air annulus in the space between the shield building and the containment vessel, a shield baffle means positioned in the air annulus around at least a portion of the sides of the containment vessel providing a coolant path between the baffle means and the containment vessel to permit cooling of the containment vessel by air, the shield baffle means being movable to afford access to the containment vessel.

Orr, Richard S. (Pittsburgh, PA)

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Large panel design for containment air baffle  

DOE Patents [OSTI]

The movable air baffle shield means in accordance with the present invention provides an efficient method of cooling the space surrounding the containment vessel while also providing the capability of being moved away from the containment vessel during inspection. The containment apparatus comprises a generally cylindrical sealed containment vessel for containing at least a portion of a nuclear power generation plant, a disparate shield building surrounding and housing the containment vessel therein and spaced outwardly thereof so as to form an air annulus in the space between the shield building and the containment vessel, a shield baffle means positioned in the air annulus around at least a portion of the sides of the containment vessel providing a coolant path between the baffle means and the containment vessel to permit cooling of the containment vessel by air, the shield baffle means being movable to afford access to the containment vessel. 9 figs.

Orr, R.S.

1992-12-08T23:59:59.000Z

442

Rating of Mixed Split Residential Air Conditioners  

E-Print Network [OSTI]

A methodology is presented for rating the performance of mixed, split residential air conditioners. The method accounts for the impact on system performance of the indoor evaporator, expansion device and fan; three major components that are likely...

Domanski, P. A.

1988-01-01T23:59:59.000Z

443

Air Activation Following an Atmospheric Explosion  

SciTech Connect (OSTI)

In addition to thermal radiation and fission products, nuclear explosions result in a very high flux of unfissioned neutrons. Within an atmospheric nuclear explosion, these neutrons can activate the various elemental components of natural air, potentially adding to the radioactive signature of the event as a whole. The goal of this work is to make an order-of-magnitude estimate of the total amount of air activation products that can result from an atmospheric nuclear explosion.

Lowrey, Justin D.; McIntyre, Justin I.; Prichard, Andrew W.; Gesh, Christopher J.

2013-03-13T23:59:59.000Z

444

Phenomenology of cosmic ray air showers  

E-Print Network [OSTI]

The properties of cosmic rays with energies above 1PeV have to be deduced from the spacetime structure and particle content of the air showers which they initiate. In this review, a summary of the phenomenology of these giant air showers is presented. We describe the hadronic interaction models used to extrapolate results from collider data to ultra high energies, an also the main electromagnetic processes that govern the longitudinal shower evolution as well as the lateral spread of particles.

M. T. Dova

2005-05-30T23:59:59.000Z

445

Compressed Air Systems Audits - Why? And How?  

E-Print Network [OSTI]

% of the compressed air costs, most with little or no capital investment. Almost always, in the event of a capital outlay, energy savings alone afford less than one-year payback. Many energy utility companies energetically support these efforts, and some.... Secondly, join us in the definition of compressed air as a system, the totality of which is comprised of the Supply Side and the Demand Side. The Supply Side is the compressors and their controls, receivers (primary storage tanks), aftercoolers, filters...

Kemp, H. L.

2004-01-01T23:59:59.000Z

446

Hanford Site air operating permit application  

SciTech Connect (OSTI)

The Clean Air Act Amendments of 1990, which amended the Federal Clean Air Act of 1977, required that the US Environmental Protection Agency develop a national Air Operating Permit Program, which in turn would require each state to develop an Air Operating Permit Program to identify all sources of ``regulated`` pollutants. Regulated pollutants include ``criteria`` pollutants (oxides of nitrogen, sulfur oxides, total suspended particulates, carbon monoxide, particulate matter greater than 10 micron, lead) plus 189 other ``Hazardous`` Air Pollutants. The Hanford Site, owned by the US Government and operated by the US Department of Energy, Richland Operations Office, is located in southcentral Washington State and covers 560 square miles of semi-arid shrub and grasslands located just north of the confluence of the Snake and Yakima Rivers with the Columbia River. This land, with restricted public access, provides a buffer for the smaller areas historically used for the production of nuclear materials, waste storage, and waste disposal. About 6 percent of the land area has been disturbed and is actively used. The Hanford Site Air Operating Permit Application consists of more than 1,100 sources and in excess of 300 emission points. Before January 1995, the maintenance and operations contractor and the environmental restoration contractor for the US Department of Energy completed an air emission inventory on the Hanford Site. The inventory has been entered into a database so that the sources and emission points can be tracked and updated information readily can be retrieved. The Hanford Site Air Operating Permit Application contains information current as of April 19, 1995.

NONE

1995-05-01T23:59:59.000Z

447

Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)  

SciTech Connect (OSTI)

This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

Kozubal, E.

2013-02-01T23:59:59.000Z

448

E-Print Network 3.0 - air-conditioners furnaces air Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Residential Space Summary: and electricity. These include boilers and furnaces for heating, air-conditioning systems and heat-pump systems... ) Space Heating Only Furnaces:...

449

Air Electrode Design for Sustained High Power Operation of Li/air Batteries  

SciTech Connect (OSTI)

The rapid development of portable electronic devices increasingly requires much more energy to support advanced functions. However, currently available batteries do not meet the high energy requirement of these devices. Metal/air batteries, especially Li/air batteries, have a much higher specific energy than most other available batteries, but their power rate is limited by the accumulation of reaction products in the air electrode. Several approaches to improve the power rate of Li/air batteries have been analyzed in this work, including adjustment of air electrode porosity and catalyst reactivity distributions to minimize diffusion limitations and maximize air electrode material utilization. An interconnected dual pore system (one catalyzed and one noncatalyzed) is proposed to improve oxygen transport into the inner regions of the air electrode, but this approach alone cannot supply high power for long term applications. A time-release multiple catalyst approach is analyzed to provide temporal release of reactivity in the air electrode. When coupled with the dual pore configuration and catalysts with high reactivities, the time-release catalyst concept can extend the duration of higher powers to longer times, and result in maximum utilization of air electrode materials.

Williford, Ralph E.; Zhang, Jiguang

2009-08-31T23:59:59.000Z

450

E-Print Network 3.0 - air volume air Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Use Summary: pressure, and for modeling the change in system pressure as function of compressed air storage volume... important system variables such as system pressure and...

451

INFLUENCE OF SUPPLY AIR TEMPERATURE ON UNDERFLOOR AIR DISTRIBUTION (UFAD) SYSTEM ENERGY PERFORMANCE  

E-Print Network [OSTI]

chilled water cooling coil, and supply fan. The fan is aspecify the VAV box cooling design supply air temperature (the underfloor supply plenum (thereby, reducing room cooling

2012-01-01T23:59:59.000Z

452

Bioinformatics in the information age  

SciTech Connect (OSTI)

There is a well-known story about the blind man examining the elephant: the part of the elephant examined determines his perception of the whole beast. Perhaps bioinformatics--the shotgun marriage between biology and mathematics, computer science, and engineering--is like an elephant that occupies a large chair in the scientific living room. Given the demand for and shortage of researchers with the computer skills to handle large volumes of biological data, where exactly does the bioinformatics elephant sit? There are probably many biologists who feel that a major product of this bioinformatics elephant is large piles of waste material. If you have tried to plow through Web sites and software packages in search of a specific tool for analyzing and collating large amounts of research data, you may well feel the same way. But there has been progress with major initiatives to develop more computing power, educate biologists about computers, increase funding, and set standards. For our purposes, bioinformatics is not simply a biologically inclined rehash of information theory (1) nor is it a hodgepodge of computer science techniques for building, updating, and accessing biological data. Rather bioinformatics incorporates both of these capabilities into a broad interdisciplinary science that involves both conceptual and practical tools for the understanding, generation, processing, and propagation of biological information. As such, bioinformatics is the sine qua non of 21st-century biology. Analyzing gene expression using cDNA microarrays immobilized on slides or other solid supports (gene chips) is set to revolutionize biology and medicine and, in so doing, generate vast quantities of data that have to be accurately interpreted (Fig. 1). As discussed at a meeting a few months ago (Microarray Algorithms and Statistical Analysis: Methods and Standards; Tahoe City, California; 9-12 November 1999), experiments with cDNA arrays must be subjected to quality control. Variables as simple as temperature and illumination differences across a microarray slide can alter readings. Between slides, additional variables add to the difficulty of comparison. For example, John Quackenbush (The Institute for Genomic Research) described the complexities associated with assuring quality control between microarray slides in a presentation both humorous and disquieting in which he demonstrated how air conditioning can affect sample readouts. Manfred Zorn (Lawrence Berkeley National Laboratory, LBNL), chair of a working group on standards, launched a preliminary effort to lay down definitions and standards for microarray analysis with particular emphasis on experimental design, measurement, and analysis documentation.

Spengler, Sylvia J.

2000-02-01T23:59:59.000Z

453

aged korean adults: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AGING & SOCIETY Engineering Websites Summary: DEPARTMENT OF HEALTH, AGING & SOCIETY Monthly Speaker Series Dr. Ellen B. Ryan DATE TIME ROOM Department of Health, Aging, &...

454

Atmospheric Environment 38 (2004) 28412865 Cleaning products and air fresheners  

E-Print Network [OSTI]

Atmospheric Environment 38 (2004) 2841­2865 Cleaning products and air fresheners: exposure of certain cleaning products and air fresheners. In addition, many cleaning agents and air fresheners contain chemicals that can react with other air contaminants to yield potentially harmful secondary products

Short, Daniel

455

Executive Summary Critique Air Products and Chemicals, Inc.  

E-Print Network [OSTI]

ME440W Executive Summary Critique Air Products and Chemicals, Inc. Low Fin Tube Heat Exchanger as compared to the bare tubes. However, contrary to Air Products' argument that the heat exchangers were to reduce turbulence of the air before it reaches the fan. The inline fan pulls the air through the test

Demirel, Melik C.

456

Air pollution and asthma severity in adults Rage Estelle 1 *  

E-Print Network [OSTI]

Air pollution and asthma severity in adults Rage Estelle 1 * , Siroux Val rieé 2 , K nzliü Nino 3 4 that exposure to air pollution affects asthma, but the effect of air pollution on asthma severity has not been outdoor concentrations of air pollution. Methods Asthma severity over the last 12 months was assessed

Paris-Sud XI, Université de

457

Ability of Catalytic Converters to Reduce Air Pollution  

E-Print Network [OSTI]

NOx - 1 Ability of Catalytic Converters to Reduce Air Pollution MEASUREMENT OF SELECTED AIR POLLUTANTS IN CAR EXHAUST Last updated: June 17, 2014 #12;NOx - 2 Ability of Catalytic Converters to Reduce Air Pollution MEASUREMENT OF SELECTED AIR POLLUTANTS IN CAR EXHAUST INTRODUCTION Automobile engines

Nizkorodov, Sergey

458

The University of Winnipeg Air Quality Management Policy  

E-Print Network [OSTI]

1 The University of Winnipeg Air Quality Management Policy TITLE: AIR QUALITY NUMBER: 90 & Sustainability) Purpose: The University of Winnipeg (the "University) Air Quality Management Policy ("Policy") establishes a framework within which the University will incorporate air quality management into its overall

Martin, Jeff

459

INTEGRATION OF WIND TURBINES WITH COMPRESSED AIR ENERGY STORAGE  

E-Print Network [OSTI]

and an unpredictable nature, can be overcome. After an overview on storage systems, the Compressed Air

I. Arsie; V. Marano; G. Rizzo; M. Moran

460

Air Traffic Control Using Virtual Stationary Automata Matthew D. Brown  

E-Print Network [OSTI]

Air Traffic Control Using Virtual Stationary Automata by Matthew D. Brown B.S., Massachusetts by . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Arthur C. Smith Chairman, Department Committee on Graduate Students #12;Air Traffic Control Using Virtual of Engineering Abstract As air travel has become an essential part of modern life, the air traffic control system

Lynch, Nancy

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Air Quality 4 4-1 2003 SITE ENVIRONMENTAL REPORT  

E-Print Network [OSTI]

Air Quality 4 4-1 2003 SITE ENVIRONMENTAL REPORT Brookhaven National Laboratory monitors both with the requirements of the Clean Air Act. In addition, the Laboratory conducts ambient air monitoring to verify local air quality and assess possible environmental impacts from BNL operations. During 2003, BNL facilities

Homes, Christopher C.

462

Air Effects on Large Droplet Impact Frank T Smith1  

E-Print Network [OSTI]

Air Effects on Large Droplet Impact Frank T Smith1 and Richard Purvis2 UCL, London WC1E 6BT, UK A study is presented of the interaction(s) between air and water in determining the motion of a large surrounding air motion. I.Nomenclature A = magnitude of shear flow in the air c = ratio U /V D

Purvis, Richard

463

Increasing Air Traffic: What is the Problem? Areski Hadjaz  

E-Print Network [OSTI]

Increasing Air Traffic: What is the Problem? Areski Hadjaz Thales Air Systems, Rungis, France Email: areski.hadjaz@thalesgroup.com Ga´etan Marceau Thales Air Systems and TAO, Rungis, France Email: gaetan efforts are made to modernize the air traffic management systems to cope with uncertainty, complexity

Boyer, Edmond

464

Air Quality and Emissions Impacts of Heat Island Mitigation Strategies  

E-Print Network [OSTI]

Air Quality and Emissions Impacts of Heat Island Mitigation Strategies ENVIRONMENTAL AREA RESEARCH the temperature of the ground surface and the ambient air. This situation creates areas called urban heat summertime temperatures reduces electricity demand for air conditioning, which lowers air pollution levels

465

Implementing Enterprise Lean A Look at Ogden Air Logistics Center  

E-Print Network [OSTI]

This paper documents the enterprise-wide lean implementation effort at Ogden Air Logistics Center, Hill

Rebentisch, Dr. Eric E.

2004-07-30T23:59:59.000Z

466

Seawater Air Conditioning for Downtown Engineering Project Manager  

E-Print Network [OSTI]

Seawater Air Conditioning for Downtown Honolulu Scott Higa Engineering Project Manager Honolulu Seawater Air Conditioning, LLC Abstract As a tropical island state, Hawaii has a year-round demand for air conditioning. Conventional air conditioning systems are energy intensive and represent close to 50 percent

Frandsen, Jannette B.

467

STRATEGIC PLAN TO REDUCE THE ENERGY IMPACT OF AIR CONDITIONERS  

E-Print Network [OSTI]

Acknowledgements This report represents the efforts of many experts from the air conditioning industry who Manufacturer Freus Air Conditioning Jim Bazemore Consultant Energy Market Innovations, Inc. Doug Beaman of Heating and Air Conditioning Industries Kahn Air Conditioning Tav Commins Staff, Buildings

468

uide for the University of Utah Air Quality  

E-Print Network [OSTI]

pollution. Regulating air pollution is a priority of the federal government because air pollution can cause adverse health effects in humans.1 The Wasatch Front is plagued with poor air quality during the winter to trapped pollution. Air pollution in the Salt Lake Valley is characterized by high levels of particulate

Tipple, Brett

469

Session 2: Modelling air pollution across a range of scales  

E-Print Network [OSTI]

of Edinburgh BHF Centre for Cardiovascular Science Scottish Air Pollution and Health Workshop School;The health effects of air pollution The world-wide effects of air pollution are considerable MORTALITYSession 2: Modelling air pollution across a range of scales Ruth Doherty, Massimo Vieno, Ian Mac

470

Combustion Air Preheat Should Be More Than Simply Recycling Energy  

E-Print Network [OSTI]

Combustion air preheat can and should result in fuel savings far in excess of the energy added to the combustion air. In a typical installation of air preheat on a fired tubular reactor, the addition of 2.5 million BTU/hr to the combustion air...

Grantom, R. L.

1980-01-01T23:59:59.000Z

471

POWER CHARACTERISTICS OF INDUSTRIAL AIR COMPRESSORS Chris Schmidt  

E-Print Network [OSTI]

of control, and potential problems such as inadequate compressed air storage, over-sized compressors are compared to suggested guidelines for energy-efficient air compression. INTRODUCTION Compressed air's annual electric costs, and the unit energy cost of compressed air ranges from about $0.15 to $0.35 per

Kissock, Kelly

472

Fault Tolerant Oxygen Control of a Diesel Engine Air System  

E-Print Network [OSTI]

Fault Tolerant Oxygen Control of a Diesel Engine Air System Rainer Nitsche Matthias Bitzer control problem of a Diesel engine air system having a jammed Exhaust Gas Recirculation (EGR) valve of the air system. Keywords: Fault tolerant control, Diesel engine, Air system, Model-based trajectory

Paris-Sud XI, Universit de

473

Predicting air quality in smart environments Seun Deleawea  

E-Print Network [OSTI]

attributable to air pollution, 1.5 million of these from indoor air pollution. Worldwide there are more deathsPredicting air quality in smart environments Seun Deleawea , Jim Kusznirb , Brian Lambb and Diane J that is often overlooked in maintaining a healthy lifestyle is the air quality of the environment. In this paper

Cook, Diane J.

474

Materials Research in the Information Age  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Materials Research in the Information Age Accelerating Advanced Material Development NERSC Science Gateway a 'Google of Material Properties' October 31, 2011 | Tags: Materials...

475

Combustor air flow control method for fuel cell apparatus  

DOE Patents [OSTI]

A method for controlling the heat output of a combustor in a fuel cell apparatus to a fuel processor where the combustor has dual air inlet streams including atmospheric air and fuel cell cathode effluent containing oxygen depleted air. In all operating modes, an enthalpy balance is provided by regulating the quantity of the air flow stream to the combustor to support fuel cell processor heat requirements. A control provides a quick fast forward change in an air valve orifice cross section in response to a calculated predetermined air flow, the molar constituents of the air stream to the combustor, the pressure drop across the air valve, and a look up table of the orifice cross sectional area and valve steps. A feedback loop fine tunes any error between the measured air flow to the combustor and the predetermined air flow.

Clingerman, Bruce J. (Palmyra, NY); Mowery, Kenneth D. (Noblesville, IN); Ripley, Eugene V. (Russiaville, IN)

2001-01-01T23:59:59.000Z

476

Analysis of the Interaction Between Air Transportation and Economic Activity: A Worldwide Perspective  

E-Print Network [OSTI]

Air transportation usage and economic activity are interdependent. Air transportation provides employment

Ishutkina, Mariya A.

2011-10-14T23:59:59.000Z

477

Analysis of the Interaction Between Air Transportation and Economic Activity: A Worldwide Perspective  

E-Print Network [OSTI]

Air transportation usage and economic activity are interdependent. Air transportation provides employment

Hansman, R. John

2009-03-30T23:59:59.000Z

478

Thermal decay in underfloor air distribution (UFAD) systems: Fundamentals and influence on system performance  

E-Print Network [OSTI]

Underfloor Air Distribution (UFAD) Design Guide. Atlanta:for design cooling loads in underfloor air distribution (

Lee, Kwang Ho; Schiavon, Stefano; Bauman, Fred; Webster, Tom

2012-01-01T23:59:59.000Z

479

The Effect of Reduced Evaporator Air Flow on the Performance of a Residential Central Air Conditioner  

E-Print Network [OSTI]

This paper discusses the measured degradation in performance of a residential air conditioning system operating under reduced evaporator air flow. Experiments were conducted using a R-22 three-ton split-type cooling system with a short-tube orifice...

Palani, M.; O'Neal, D.; Haberl, J.

480

CLEARING THE AIR? THE EFFECTS OF GASOLINE CONTENT REGULATION ON AIR QUALITY  

E-Print Network [OSTI]

)--are pollutants produced in part through human activity. Ozone control programs have targeted a wide array of VOCCLEARING THE AIR? THE EFFECTS OF GASOLINE CONTENT REGULATION ON AIR QUALITY Maximilian Auffhammer regulations on ground- level ozone pollution. These regulations are costly and have been shown to fragment

Edwards, Paul N.

Note: This page contains sample records for the topic "aged air condi" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Problem Type Problem Type Description Air Conditioning Air conditioner not working, leaking, etc  

E-Print Network [OSTI]

Problem Type Problem Type Description Air Conditioning Air conditioner not working, leaking, etc, Microfridges Doors and Hardware Door repair/replace Lock, latch or hinge repair, key stuck; Lost or stolen key, repair or replace Shades/Blinds Window treatment - repair or replace Washer/Dryer Washer/Dryer repair

Tennessee, University of

482

Measure Guideline: Guide to Attic Air Sealing  

SciTech Connect (OSTI)

The Guide to Attic Air Sealing was completed in 2010 and although not in the standard Measure Guideline format, is intended to be a Measure Guideline on Attic Air Sealing. The guide was reviewed during two industry stakeholders meetings held on December 18th, 2009 and January 15th, 2010, and modified based on the comments received. Please do not make comments on the Building America format of this document. The purpose of the Guide to Attic Air Sealing is to provide information and recommendations for the preparation work necessary prior to adding attic insulation. Even though the purpose of this guide is to save energy - health, safety and durability should not be compromised by energy efficiency. Accordingly, combustion safety and ventilation for indoor air quality are addressed first. Durability and attic ventilation then follow. Finally, to maximize energy savings, air sealing is completed prior to insulating. The guide is intended for home remodelers, builders, insulation contractors, mechanical contractors, general contractors who have previously done remodeling and homeowners as a guide to the work that needs to be done.

Lstiburek, J.

2014-09-01T23:59:59.000Z

483

IEA Heat Pump Conference 2011, 16 -19 May 2011, Tokyo, Japan ENERGY EFFICIENT AIR TO AIR HEAT PUMP OPERATING WITH  

E-Print Network [OSTI]

00149 -1- 10th IEA Heat Pump Conference 2011, 16 - 19 May 2011, Tokyo, Japan ENERGY EFFICIENT AIR TO AIR HEAT PUMP OPERATING WITH R-1234yf Sorina Mortada, Ph.D. student, Center for Energy and Processes Abstract: Significant improvements in energy performance of air-to-air heat pumps are the major reason

Paris-Sud XI, Université de

484

Indoor Air Quality Fact Sheet Poor indoor air quality comes from many sources. It can lead to suffering from lung  

E-Print Network [OSTI]

, and charcoal · Household products such as cleaners and pesticides How to Improve Indoor Air Quality · OpenIndoor Air Quality Fact Sheet Poor indoor air quality comes from many sources. It can lead Indoor Air Pollutants · Molds · Pollen · Dander from pet fur · Secondhand smoke · Formaldehyde · Fumes

485

Air Potato Leaf Feeding Beetle (Lilioceris cheni) Request Form/ Air Potato Vine (Dioscorea bulbifera) Infestation Site Record  

E-Print Network [OSTI]

Air Potato Leaf Feeding Beetle (Lilioceris cheni) Request Form/ Air Potato Vine: Longitude: Size/Density Approximate total size of the air potato vine infestation: Percent of the total area (above) covered by air potato vines (0100%): Other remarks: Please send data sheets to

Florida, University of

486

Abstract--For a Compressed Air Energy Storage (CAES) approach to be viable, the air compressor/expander must be  

E-Print Network [OSTI]

Abstract-- For a Compressed Air Energy Storage (CAES) approach to be viable, the air compressor improvement can also be determined using this method. I. INTRODUCTION novel Compressed Air Energy Storage advantage of pneumatics. High pressure (~20-30MPa) compressed air is stored in a dual chamber storage vessel

Li, Perry Y.

487

EECBG Direct Equipment Purchase Air Conditioner Guide Equipment Type  

E-Print Network [OSTI]

EECBG Direct Equipment Purchase Air Conditioner Guide Equipment Type Size Category (Btu/h) Size.ahridirectory.org/ceedirectory/pages/ac/cee/defaultSearch.aspx 12,000 Btu/h = 1 ton Less than 65,000 Btu/h Air Conditioners, Air Cooled Air Conditioners, Water completed by the California Energy Commission at a rate of 12,000 Btu/h per ton of air conditioning Source

488

Exploring the concept of compressed air energy storage (CAES) in lined rock caverns at shallow depth: A modeling study of air tightness and energy balance  

E-Print Network [OSTI]

wind- diesel-compressed air energy storage system for remotestudy for the compressed air energy storage technology bydesign of compressed air energy storage electric power

Kim, H.-M.

2012-01-01T23:59:59.000Z

489

Air separation by the Moltox process  

SciTech Connect (OSTI)

The report describes results of a development program on a new and energy saving process for air separation. The Moltox process involves reversibly reacting oxygen in air with a recirculating salt solution, such that oxygen is extracted without depressurizing the remaining nitrogen. Energy savings of approximately 50% are indicated for this process compared to conventional cryogenic air separation. The development program consisted of design, construction, and operation of a 6 liter/minute pilot plant; optimization of the process flowsheet through computer modelling; investigation of engineering aspects of the process including corrosion, safety, and NO/sub x/ generation; and an economic comparison to conventional cryogenic practice. All objectives were satisfactorily achieved except for continuous operation of the pilot plant, and the modifications necessary to achieve that have been identified. Economically the Moltox process shows a substantial advantage over large scale cryogenic plants which are powered by fuel vice electricity.

Erickson, D. C.

1981-04-01T23:59:59.000Z

490

Solar Powered Radioactive Air Monitoring Stations  

SciTech Connect (OSTI)

Environmental monitoring of ambient air for radioactive material is required as stipulated in the PNNL Site radioactive air license. Sampling ambient air at identified preferred locations could not be initially accomplished because utilities were not readily available. Therefore, solar powered environmental monitoring systems were considered as a possible option. PNNL purchased two 24-V DC solar powered environmental monitoring systems which consisted of solar panels, battery banks, and sampling units. During an approximate four month performance evaluation period, the solar stations operated satisfactorily at an on-site test location. They were subsequently relocated to their preferred locations in June 2012 where they continue to function adequately under the conditions found in Richland, Washington.

Barnett, J. M.; Bisping, Lynn E.; Gervais, Todd L.

2013-10-30T23:59:59.000Z

491

Commissioning to avoid indoor air quality problems  

SciTech Connect (OSTI)

This paper reports on indoor air quality (IAQ) which has become a pervasive problem plaguing the building industry worldwide. Poor IAQ in commercial and office buildings is primarily related to new building technology, new materials and equipment and energy management operating systems. Occupants of buildings with air quality problems suffer from a common series of symptoms. As early as 1982, ASHRAE, realizing the significance of the problem, produced an IAQ position statement that identified strategies for solving IAQ problems. Many of those strategies have now been implemented, including Standard 62-1989, Ventilation for Acceptable Air Quality; Standard 90.1, Energy Efficient Design of New Buildings Except Low-Rise Residential Buildings; the 100 series of energy standards; and Guideline 1, Guideline for Commissioning of HVAC Systems.

Sterling, E.M.; Collett, C.W. (Theodore D. Sterling and Associates, Ltd., Vancouver, British Columbia (Canada)); Turner, S. (Healthy Buildings International Inc., Fairfax, VA (United States)); Downing, C.C. (Environmental Science and Technology Lab., Georgia Technology Research Inst., Atlanta, GA (United States))

1992-10-01T23:59:59.000Z

492

Secondary air injection system and method  

DOE Patents [OSTI]

According to one embodiment of the invention, a secondary air injection system includes a first conduit in fluid communication with at least one first exhaust passage of the internal combustion engine and a second conduit in fluid communication with at least one second exhaust passage of the internal combustion engine, wherein the at least one first and second exhaust passages are in fluid communication with a turbocharger. The system also includes an air supply in fluid communication with the first and second conduits and a flow control device that controls fluid communication between the air supply and the first conduit and the second conduit and thereby controls fluid communication to the first and second exhaust passages of the internal combustion engine.

Wu, Ko-Jen; Walter, Darrell J.

2014-08-19T23:59:59.000Z

493

High strength air-dried aerogels  

DOE Patents [OSTI]

A method for the preparation of high strength air-dried organic aerogels. The method involves the sol-gel polymerization of organic gel precursors, such as resorcinol with formaldehyde (RF) in aqueous solvents with R/C ratios greater than about 1000 and R/F ratios less than about 1:2.1. Using a procedure analogous to the preparation of resorcinol-formaldehyde (RF) aerogels, this approach generates wet gels that can be air dried at ambient temperatures and pressures. The method significantly reduces the time and/or energy required to produce a dried aerogel compared to conventional methods using either supercritical solvent extraction. The air dried gel exhibits typically less than 5% shrinkage.

Coronado, Paul R.; Satcher, Jr., Joe H.

2012-11-06T23:59:59.000Z

494

Equivalence in Ventilation and Indoor Air Quality  

SciTech Connect (OSTI)

We ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum ventilation rates without taking into account the impact of those rates on IAQ. Innovative ventilation management is often a desirable element of reducing energy consumption or improving IAQ or comfort. Variable ventilation is one innovative strategy. To use variable ventilation in a way that meets standards, it is necessary to have a method for determining equivalence in terms of either ventilation or indoor air quality. This study develops methods to calculate either equivalent ventilation or equivalent IAQ. We demonstrate that equivalent ventilation can be used as the basis for dynamic ventilation control, reducing peak load and infiltration of outdoor contaminants. We also show that equivalent IAQ could allow some contaminants to exceed current standards if other contaminants are more stringently controlled.

Sherman, Max; Walker, Iain; Logue, Jennifer

2011-08-01T23:59:59.000Z

495

Indoor air quality: The legal landscape II  

SciTech Connect (OSTI)

Today`s office environment is as different from its predecessor as an automobile is from a horse and buggy. A 1950s office typically contained tile floors, painted walls, plaster ceilings, carbon paper, and plentiful fresh air circulating through windows that were usually open when weather permitted. In the 1990s, the decor has shifted to carpeted floors, synthetic wall coverings, ceiling tile and multiple copiers. Sophisticated building materials and motorized office products can emit unwelcome constituents into the indoor air, yet ventilation is limited by windows that do not open. One result of these changes has been an unprecedented and ever-increasing concern about indoor air quality (IAQ). Some studies rank indoor air pollution as today`s number one environmental health risk. Increased media attention to the topic has increased public awareness, which has increased litigation and regulatory activity in the area. This paper explores the legal landscape of IAQ in the US, ranging from legislative to regulatory activity on both the federal and state levels, and from civil litigation to actions brought before administrative boards. Along the way, the paper defines and discusses such IAQ problems as building-related illness (BRI) and sick building syndrome (SBS), examining the magnitude of the problems and their possible causes. Finally, the paper provides suggestions to those potentially liable for alleged injuries from indoor air pollution, including architects, builders, contractors, building product manufacturers, building owners and managers, building sellers, employers, and engineering and environmental consultants. This paper is an update of a paper presented at the Air and Waste Management Association`s Annual Meeting in 1992.

Neet, J.O. Jr.; Smith, T.A. [Shook, Hardy and Bacon, Kansas City, MO (United States)

1997-12-31T23:59:59.000Z

496

UNDEREMPLOYMENT AMONG MATURE AGE WORKERS IN AUSTRALIA  

E-Print Network [OSTI]

1 UNDEREMPLOYMENT AMONG MATURE AGE WORKERS IN AUSTRALIA * Jinjing Li1 , Alan Duncan2 and Riyana Miranti1 1 NATSEM, University of Canberra, Australia 2 Bankwest Curtin Economics Centre, Curtin University of underemployment for mature aged workers in Australia, and seeks in particular to determine the principal factors

497

6, 39453963, 2006 Methanol inside aged  

E-Print Network [OSTI]

. The oxidation of methane (and other hydrocarbons) can also produce methanol primarily via the self reactionACPD 6, 3945­3963, 2006 Methanol inside aged tropical biomass burning plumes G. Dufour et al. Title Chemistry and Physics Discussions First space-borne measurements of methanol inside aged tropical biomass

498

Total Building Air Management: When Dehumidification Counts  

E-Print Network [OSTI]

are realized when systems are designed with a total operating strategy in mind. Thls strategy takes Cheryl L. White Technical Consultant Eddleson & Rowe, Assoc. Denver, Colorado into consideration every factor of buildmg air management includmg: 1...-89 specifies at least 15 CFM per person. In Denver Colorado where relative humidity of outdoor air is low and outdoor design temperature is 92" F DB/65" F WB, this may be a cost effective method of assuring high IAQ. In other parts of the country - Houston...

Chilton, R. L.; White, C. L.

1996-01-01T23:59:59.000Z

499

Measured Impacts of Air Conditioner Condenser Shading  

E-Print Network [OSTI]

reaching the expansion valve. In theory, the efficiency of vapor compression air conditioning can be improved through two primary mechanisms associated with condenser shading: Direct shading. Incident solar radiation can pose approximately a 1,000 w...]: IEYPERAlURL COUPARlSOn A/C SHADING DP. 1 (Some): SOUR RADlAllON COUPARISON I=AYEI[Nl KYP orq=82.1 , mu=87.(22 Z=CONDEHSIR ARU AIR lEYP orq=83.8 , mox=02.858 TIME OF DAY, (hr) 9 12 15 TIME OF DAY, (hr) Figure 3. Sample daily 15-minute data for June 21...

Parker, D. S.; Barkaszi, S. F.; Sonne, J. K.

1996-01-01T23:59:59.000Z

500

Liquid metal reactor air cooling baffle  

DOE Patents [OSTI]

A baffle is provided between a relatively hot containment vessel and a relatively cold silo for enhancing air cooling performance. The baffle includes a perforate inner wall positionable outside the containment vessel to define an inner flow riser therebetween, and an imperforate outer wall positionable outside the inner wall to define an outer flow riser therebetween. Apertures in the inner wall allow thermal radiation to pass laterally therethrough to the outer wall, with cooling air flowing upwardly through the inner and outer risers for removing heat. 3 figs.

Hunsbedt, A.

1994-08-16T23:59:59.000Z