Powered by Deep Web Technologies
Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Federal Railroad Administration  

Broader source: Energy.gov (indexed) [DOE]

Manager Federal Railroad Administration Federal Railroad Administration Dedicated Train Study- Report to Congress FRA' s Research & Development Office (as lead on the study)...

2

Federal Railroad Administration  

Broader source: Energy.gov (indexed) [DOE]

Transportation Federal Railroad Administration Overview of Proposed Rail Safety & Security Rulemakings Kevin R. Blackwell FRA Hazmat Division Washington, DC Federal Authority DOT...

3

Federal Aviation Administration  

E-Print Network [OSTI]

transportation systems FAA's RDT&E Organization: Federal Laboratory for R&D of aviation systems IndependentFederal Aviation Administration Federal Aviation AdministrationNextGen: Primer, Challenges. Wilson N. Felder Director, FAA William J. Hughes Technical Center Date: 6 February 2012 #12;2Federal

4

Federal Railroad Administration  

Broader source: Energy.gov (indexed) [DOE]

- HQ Hazmat Division, Washington, DC. Federal Railroad Administration Dedicated Train Study - Report to Congress November 2003 - FRA' s Ofc. Of Research & Development...

5

ARRA FEMP Technical Assistance -- Federal Aviation Administration Project 209 -- Control Tower and Support Building, Palm Springs, CA  

SciTech Connect (OSTI)

This report represents findings of a design review team that evaluated construction documents (at the 100% level) and operating specifications for a new control tower and support building that will be built in Palm Springs, California by the Federal Aviation Administration (FAA). The focus of the review was to identify measures that could be incorporated into the final design and operating specifications that would result in additional energy savings for the FAA that would not have otherwise occurred.

Arends, J.; Sandusky, William F.

2010-03-31T23:59:59.000Z

6

Federal Buildings Supplemental Survey 1993  

SciTech Connect (OSTI)

The Energy Information Administration (EIA) of the US Department of Energy (DOE) is mandated by Congress to be the agency that collects, analyzes, and disseminates impartial, comprehensive data about energy including the volume consumed, its customers, and the purposes for which it is used. The Federal Buildings Supplemental Survey (FBSS) was conducted by EIA in conjunction with DOE`s Office of Federal Energy Management Programs (OFEMP) to gain a better understanding of how Federal buildings use energy. This report presents the data from 881 completed telephone interviews with Federal buildings in three Federal regions. These buildings were systematically selected using OFEMP`s specifications; therefore, these data do not statistically represent all Federal buildings in the country. The purpose of the FBSS was threefold: (1) to understand the characteristics of Federal buildings and their energy use; (2) to provide a baseline in these three Federal regions to measure future energy use in Federal buildings as required in EPACT; and (3) to compare building characteristics and energy use with the data collected in the CBECS.

NONE

1995-11-01T23:59:59.000Z

7

American Recovery and Reinvestment Act (ARRA) FEMP Technical Assistance US General Serices Administration - Project 193, John W. Bricker Federal Building, Columbus, OH  

SciTech Connect (OSTI)

This report documents the findings from an onsite audit of the John W. Bricker Federal building located in Columbus, Ohio. The Federal landlord for this building is the General Services Administration (GSA). The focus of the audit was to identify various no-cost or low-cost energy efficiency opportunities that, once implemented, would either reduce electrical and gas consumption or increase the operational efficiency of the building. This audit also provided an opportunity to identify potential capital cost projects that should be considered in the future to acquire additional energy (electric and gas) and water savings to further increase the operational efficiency of the building.

Arends, J.; Sandusky, William F.

2010-05-31T23:59:59.000Z

8

American Recovery and Reinvestment Act (ARRA) FEMP Technical Assistance Federal Aviation Administration – Project 209 Control Tower and Support Building Oakland, CA  

SciTech Connect (OSTI)

This report represents findings of a design review team that evaluated construction documents (at the 70% level) and operating specifications for a new control tower and support building that will be build at Oakland, California by the Federal Aviation Administration (FAA). The focus of the review was to identify measures that could be incorporated into the final design and operating specification that would result in additional energy savings for the FAA that would not have otherwise occurred.

Arends, J.; Sandusky, William F.

2010-03-01T23:59:59.000Z

9

Karen Hedlund, Chief Counsel Federal Railroad Administration  

E-Print Network [OSTI]

Karen Hedlund, Chief Counsel Federal Railroad Administration Presentation to the Hagestad Sandhouse-educate, and out-build the rest of the world... That's how we'll win the future." - President Barack Obama, January China are building . . . thousands of miles of high-speed rail." - President Barack Obama, April 19

Bustamante, Fabián E.

10

American Recovery and Reinvestment Act (ARRA) FEMP Technical Assistance Federal Aviation Administration Project 209 - Control Tower and Support Building, Las Vegas, NV  

SciTech Connect (OSTI)

This report represents findings of a design review team that evaluated construction documents (at the 70% level) and operating specifications for a new control tower and support building that will be built in Las Vegas, Nevada by the Federal Aviation Administration (FAA). The focus of the review was to identify measures that could be incorporated into the final design and operating specification that would result in additional energy savings for the FAA that would not have otherwise occurred.

Arends, J.; Sandusky, William F.

2010-03-31T23:59:59.000Z

11

Federal Railroad Administration  

Broader source: Energy.gov (indexed) [DOE]

very similar to this bill in regard to the core provisions Core provisions: Review and reform the Federal hours of service requirements Establish a new risk reduction program...

12

American Recovery and Reinvestment Act (ARRA) FEMP Technical Assistance Federal Aviation Administration – Project 209 Control Tower and Support Building, Reno, Nevada  

SciTech Connect (OSTI)

Pacific Northwest National Laboratory (PNNL) and Redhorse Corporation (Redhorse) conducted an energy audit on the Federal Aviation Administration (FAA) control tower and base building in Reno, Nevada. This report presents the findings of the energy audit team that evaluated construction documents and operating specifications (at the 100% level) and completed a site visit. The focus of the review was to identify measures that could be incorporated into the final design and operating specifications that would result in additional energy savings for the FAA that would not have otherwise occurred.

Arends, J.; Sandusky, William F.

2010-06-30T23:59:59.000Z

13

ACADEMIC, ADMINISTRATIVE & MULTIPURPOSE BUILDINGS  

E-Print Network [OSTI]

ACADEMIC, ADMINISTRATIVE & MULTIPURPOSE BUILDINGS 1 Albright Health Center (HC) 2 Applied Science S SIBIL I T Y M A P R E V I S E D M AY 2 0 0 7 L Open Parking M Student Parking N Reserved Parking O Open/VIP Parking P Student Parking Q Student Parking R Student Parking** S Open Parking T Open Parking U Student

Boyce, Richard L.

14

American Recovery and Reinvestment Act (ARRA) FEMP Technical Assistance U.S. General Services Administration – Project 195 John Seiberling Federal Office Building and U.S. Courthouse, Akron, Ohio  

SciTech Connect (OSTI)

This report documents the findings from an onsite audit of the John Seiberling Federal building located in Akron, Ohio. The Federal landlord for this building is the General Services Administration (GSA). The focus of the audit was to identify various no-cost or low-cost energy efficiency opportunities that, once implemented, would reduce in either electrical and gas consumption and increase the operational efficiency of the building. This audit also provided an opportunity to identify potential capital cost projects that should be considered in the to acquire additional energy (electric and gas) and water savings to further increase the operational efficiency of the building.

Arends, J.; Sandusky, William F.

2010-05-28T23:59:59.000Z

15

Federal Register Notice: National Nuclear Security Administration...  

Broader source: Energy.gov (indexed) [DOE]

Site-Wide Environmental Impact Statement for Sandia National Laboratories, New Mexico (SNLNM) Federal Register Notice: National Nuclear Security Administration Site-Wide...

16

Phillip Burton Federal Building EMCS Retrofit Analysis  

E-Print Network [OSTI]

and Renewable Energy, Office of Building Technology and Community Systems, and the Federal Energy ManagementPhillip Burton Federal Building EMCS Retrofit Analysis Interim Report March 1999 Rick Diamond, Tim This report presents the interim results of analyses carried out in the Phillip Burton Federal Building in San

Diamond, Richard

17

2013 Better Buildings Federal Award Frequently Asked Questions  

Broader source: Energy.gov [DOE]

Document answers frequently asked questions for the Federal Energy Management Program's 2013 Better Buildings Federal Award.

18

Federal Buildings Personnel Training Act of 2010  

Broader source: Energy.gov [DOE]

On December 14, 2010, President Obama signed the Federal Buildings Personnel Training Act of 2010 into law. This legislation will have an important impact on Federal agency training programs geared...

19

Energy Information Administration (EIA)- Commercial Buildings...  

U.S. Energy Information Administration (EIA) Indexed Site

Stock: Results from EIA's 2012 CBECS 2012 building stock results Source: U.S. Energy Information Administration, Commercial Buildings Energy Consumption Survey 2012, March...

20

Better Buildings Federal Award 2012 Competition | Department...  

Office of Environmental Management (EM)

Federal Government's highest-performing buildings through a competition to reduce annual energy use intensity (Btu per square foot of facility space) on a year-over-year basis....

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Better Buildings Federal Award 2013 Competition | Department...  

Broader source: Energy.gov (indexed) [DOE]

Federal Government's highest-performing buildings through a competition to reduce annual energy use intensity (Btu per square foot of facility space) on a year-over-year basis....

22

Fossil Fuel-Generated Energy Consumption Reduction for New Federal Buildings and Major Renovations of Federal Buildings  

Broader source: Energy.gov [DOE]

Document details Fossil Fuel-Generated Energy Consumption Reduction for New Federal Buildings and Major Renovations of Federal Buildings in a Supplemental Notice of Proposed Rulemaking.

23

Economic Energy Savings Potential in Federal Buildings  

SciTech Connect (OSTI)

The primary objective of this study was to estimate the current life-cycle cost-effective (i.e., economic) energy savings potential in Federal buildings and the corresponding capital investment required to achieve these savings, with Federal financing. Estimates were developed for major categories of energy efficiency measures such as building envelope, heating system, cooling system, and lighting. The analysis was based on conditions (building stock and characteristics, retrofit technologies, interest rates, energy prices, etc.) existing in the late 1990s. The potential impact of changes to any of these factors in the future was not considered.

Brown, Daryl R.; Dirks, James A.; Hunt, Diane M.

2000-09-04T23:59:59.000Z

24

Green Building Certification Systems Requirement for New Federal...  

Energy Savers [EERE]

greenblgcert.docx More Documents & Publications EA-1991: Final Environmental Assessment Green Building Certification Systems Requirement for New Federal Buildings and Major...

25

Federal Leadership in High Performance and Sustainable Buildings...  

Broader source: Energy.gov (indexed) [DOE]

leadership in the design, construction, and operation of High-Performance and Sustainable Buildings. Federal Leadership in High Performance and Sustainable Buildings...

26

Green Building Certification Systems Requirement for New Federal...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

CFR Parts 433, 435 and 436. greenblgcertcompare2014.docx More Documents & Publications Green Building Certification Systems Requirement for New Federal Buildings and Major...

27

Federal Highway Administration - Pilot Car Escort - Best Practices...  

Open Energy Info (EERE)

Federal Highway Administration - Pilot Car Escort - Best Practices Guidelines Jump to: navigation, search OpenEI Reference LibraryAdd to library PermittingRegulatory Guidance -...

28

Better Buildings Federal Award 2013 Guidelines for Entering  

Broader source: Energy.gov [DOE]

The Better Buildings Federal Award recognizes the Federal Government's highest-performing buildings through a competition to reduce annual energy intensity (Btu per square foot of facility space) on a year-over-year basis. The winner is the Federal building that reduces its energy intensity the most as compared to the previous year.

29

Indoor Air Quality Assessment of the San Francisco Federal Building  

SciTech Connect (OSTI)

An assessment of the indoor air quality (IAQ) of the San Francisco Federal Building (SFFB) was conducted on May 12 and 14, 2009 at the request of the General Services Administration (GSA). The purpose of the assessment was for a general screening of IAQ parameters typically indicative of well functioning building systems. One naturally ventilated space and one mechanically ventilated space were studied. In both zones, the levels of indoor air contaminants, including CO2, CO, particulate matter, volatile organic compounds, and aldehydes, were low, relative to reference exposure levels and air quality standards for comparable office buildings. We found slightly elevated levels of volatile organic compounds (VOCs) including two compounds often found in"green" cleaning products. In addition, we found two industrial solvents at levels higher than typically seen in office buildings, but the levels were not sufficient to be of a health concern. The ventilation rates in the two study spaces were high by any standard. Ventilation rates in the building should be further investigated and adjusted to be in line with the building design. Based on our measurements, we conclude that the IAQ is satisfactory in the zone we tested, but IAQ may need to be re-checked after the ventilation rates have been lowered.

Apte, Michael; Bennett, Deborah H.; Faulkner, David; Maddalena, Randy L.; Russell, Marion L.; Spears, Michael; Sullivan, Douglas P; Trout, Amber L.

2008-07-01T23:59:59.000Z

30

Federal Aviation Administration's Airport Capital Improvement Program Development Process  

E-Print Network [OSTI]

The Airport Capital Improvement Program (ACIP) serves as the primary tool for project planning and formulation by the Federal Aviation Administration (FAA). The FAA relies on the ACIP to serve as the basis for the distribution of Aviation Trust...

Tener, Scott D.

2009-12-18T23:59:59.000Z

31

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

Construction: Green Building Design and Delivery, SecondFederal Building. U.S. Green Building Council (2009). LEEDReference guide. US Green Building Council. (2006). LEED-

Konis, Kyle Stas

2012-01-01T23:59:59.000Z

32

Increasing Federal Office Building Water Efficiency, Federal Energy Management Program (FEMP) (Fact Sheet)  

SciTech Connect (OSTI)

Quick guide to increasing Federal office building water efficiency, water management planning, performing a water audit, calculating a water balance, and best management practices.

Not Available

2010-04-01T23:59:59.000Z

33

Using Dashboard to Improve Energy and Comfort in Federal Buildings  

E-Print Network [OSTI]

LBNL-4283E Using Dashboard to Improve Energy and Comfort in Federal Buildings Kyle Marini Secretary of Energy Efficiency and Renewable Energy, Federal Energy Management Program, of the U of the Building 90 monitoring team, including, Jose (Arturo) Ayala-Navarro, Geoffrey Bell, Nicholas Goodell

34

Cool roofs as an energy conservation measure for federal buildings  

SciTech Connect (OSTI)

We have developed initial estimates of the potential benefits of cool roofs on federal buildings and facilities (building scale) as well as extrapolated the results to all national facilities under the administration of the Federal Energy Management Program (FEMP). In addition, a spreadsheet ''calculator'' is devised to help FEMP estimate potential energy and cost savings of cool roof projects. Based on calculations for an average insulation level of R-11 for roofs, it is estimated that nationwide annual savings in energy costs will amount to $16M and $32M for two scenarios of increased roof albedo (moderate and high increases), respectively. These savings, corresponding to about 3.8 percent and 7.5 percent of the base energy costs for FEMP facilities, include the increased heating energy use (penalties) in winter. To keep the cost of conserved energy (CCE) under $0.08 kWh-1 as a nationwide average, the calculations suggest that the incremental cost for cool roofs should not exceed $0.06 ft-2, assuming that cool roofs have the same life span as their non-cool counterparts. However, cool roofs usually have extended life spans, e.g., 15-30 years versus 10 years for conventional roofs, and if the costs of re-roofing are also factored in, the cutoff incremental cost to keep CCE under $0.08 kWh-1 can be much higher. In between these two ends, there is of course a range of various combinations and options.

Taha, Haider; Akbari, Hashem

2003-04-07T23:59:59.000Z

35

Federal Railroad Administration | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power SystemsResourcesFLASH2011-11-OPAMFY 2007 Total System12Federal Long Tern

36

Attributes of the Federal Energy Management Program's Federal Site Building Characteristics Database  

SciTech Connect (OSTI)

Typically, the Federal building stock is referred to as a group of about one-half million buildings throughout the United States. Additional information beyond this level is generally limited to distribution of that total by agency and maybe distribution of the total by state. However, additional characterization of the Federal building stock is required as the Federal sector seeks ways to implement efficiency projects to reduce energy and water use intensity as mandated by legislation and Executive Order. Using a Federal facility database that was assembled for use in a geographic information system tool, additional characterization of the Federal building stock is provided including information regarding the geographical distribution of sites, building counts and percentage of total by agency, distribution of sites and building totals by agency, distribution of building count and floor space by Federal building type classification by agency, and rank ordering of sites, buildings, and floor space by state. A case study is provided regarding how the building stock has changed for the Department of Energy from 2000 through 2008.

Loper, Susan A.; Sandusky, William F.

2010-12-31T23:59:59.000Z

37

Sandia National Laboratories: Federal Housing Administration  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 -theErik Spoerke SSLS Exhibit at Explora Museum OnFact SheetsEnergy

38

Administration Building demolition completed under budget  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD)ProductssondeadjustsondeadjustAbout the Building TechnologiesS1!4T opAddress: ~~. .Administration

39

ORNL/TM-2003/210 THE FEDERAL HIGHWAY ADMINISTRATION  

E-Print Network [OSTI]

ORNL/TM-2003/210 THE FEDERAL HIGHWAY ADMINISTRATION GASOHOL CONSUMPTION ESTIMATION MODEL August January 1, 1996, are generally available free via the U.S. Department of Energy (DOE) Information Bridge by members of the public from the following source. National Technical Information Service 5285 Port Royal

40

Better Buildings Federal Award 2013 Guidelines for Entering ...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Federal Government's highest-performing buildings through a competition to reduce annual energy intensity (Btu per square foot of facility space) on a year-over-year basis. The...

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

John. F. O'Leary Appointed to Lead Federal Energy Administration...  

National Nuclear Security Administration (NNSA)

John. F. O'Leary Appointed to Lead Federal Energy Administration | National Nuclear Security Administration Facebook Twitter Youtube Flickr RSS People Mission Managing the...

42

ESCO Framework for Public/Federal Buildings  

E-Print Network [OSTI]

of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 Building Technologies ? Siemens 2008 Climate Change and Global Warming Not a new topic, but now with the right attention ! z z z z z z z z z z z z z z... z z No environmental awareness without economic interests Page 2 ESL-IC-08-10-01 Proceedings of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 SB T B A U /EE S ? Siemens 2008 Building...

Liehr, G.

43

Better Buildings Federal Award 2013 Competition  

Broader source: Energy.gov [DOE]

FEMP selected the following 12 finalists to compete in the 2013 competition. From now through August 30, 2013, these buildings will compete head-to-head to achieve the greatest reduction in energy...

44

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

Federal Building. U.S. Green Building Council (2009). LEEDReference guide. US Green Building Council. (2006). LEED-www.usgbc.org/LEED/ U.S. Green Building Council (from David

Konis, Kyle Stas

2011-01-01T23:59:59.000Z

45

Office of the Vice President for Research 203 Administration Building  

E-Print Network [OSTI]

Office of the Vice President for Research 203 Administration Building Fort Collins, Colorado 80523 of the Vice President for Research. The Institute builds on the long history of broad work in energy at the Powerhouse Energy Institute (when that building is completed in 2014) and Engines & Energy Conversion

46

Using Dashboards to Improve Energy and Comfort in Federal Buildings  

SciTech Connect (OSTI)

Federal agencies are taking many steps to improve the sustainability of their operations, including improving the energy efficiency of their buildings, promoting recycling and reuse of materials, encouraging carpooling and alternative transit schemes, and installing low flow water fixture units are just a few of the common examples. However, an often overlooked means of energy savings is to provide feedback to building users about their energy use through information dashboards connected to a building?s energy information system. An Energy Information System (EIS), broadly defined, is a package of performance monitoring software, data acquisition hardware, and communication systems that is used to collect, store, analyze, and display energy information. At a minimum, the EIS provides the whole-building energy-use information (Granderson 2009a). We define a ?dashboard? as a display and visualization tool that utilizes the EIS data and technology to provide critical information to users. This information can lead to actions resulting in energy savings, comfort improvements, efficient operations, and more. The tools to report analyzed information have existed in the information technology as business intelligence (Few 2006). The dashboard is distinguished from the EIS as a whole, which includes additional hardware and software components to collect and storage data, and analysis for resources and energy management (Granderson 2009b). EIS can be used for a variety of uses, including benchmarking, base-lining, anomaly detection, off-hours energy use evaluation, load shape optimization, energy rate analysis, retrofit and retro-commissioning savings (Granderson 2009a). The use of these EIS features depends on the specific users. For example, federal and other building managers may use anomaly detection to identify energy waste in a specific building, or to benchmark energy use in similar buildings to identify energy saving potential and reduce operational cost. There are several vendors of EIS technology that provide information on energy and other environmental variables in buildings.

Lawrence Berkeley National Laboratory; Marini, Kyle; Ghatikar, Girish; Diamond, Richard

2011-02-01T23:59:59.000Z

47

Federal Emergency Management Information System (FEMIS) System Administration Guide for FEMIS Version 1.5  

SciTech Connect (OSTI)

The Federal Emergency Management System (FEMIS) is an emergency management planning and response tool. The FEMIS System Administration Guide provides information on FEMIS System Administrator activities as well as the utilities that are included with FEMIS.

Bower, John C. (BATTELLE (PACIFIC NW LAB)); Burnett, Robert A. (BATTELLE (PACIFIC NW LAB)); Carter, Richard J. (BATTELLE (PACIFIC NW LAB)); Downing, Timothy R. (BATTELLE (PACIFIC NW LAB)); Homer, Brian J. (BATTELLE (PACIFIC NW LAB)); Holter, Nancy A. (BATTELLE (PACIFIC NW LAB)); Johnson, Daniel M. (BATTELLE (PACIFIC NW LAB)); Johnson, Ranata L. (BATTELLE (PACIFIC NW LAB)); Johnson, Sharon M. (BATTELLE (PACIFIC NW LAB)); Loveall, Robert M. (BATTELLE (PACIFIC NW LAB)); Ramos Jr., Juan (BATTELLE (PACIFIC NW LAB)); Schulze, Stacy A. (BATTELLE (PACIFIC NW LAB)); Sivaraman, Chitra (BATTELLE (PACIFIC NW LAB)); Stephan, Alex J. (BATTELLE (PACIFIC NW LAB)); Stoops, Lamar R. (BATTELLE (PACIFIC NW LAB)); Wood, Blanche M. (BATTELLE (PACIFIC NW LAB))

2001-12-01T23:59:59.000Z

48

2012 Better Buildings Federal Award Winners | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergy Cooperation |South Valley Responsible DOEQA: NAPlan(EE)Naval2012 Better Buildings Federal

49

E-Print Network 3.0 - administration public buildings Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

search results for: administration public buildings Page: << < 1 2 3 4 5 > >> 1 Curriculum Vitae Eric Keller Austin Summary: Journal Articles: Building on place: A conceptual...

50

the mission of the General Services Administration is to help federal agencies better  

E-Print Network [OSTI]

#12;the mission of the General Services Administration is to help federal agencies better serve .......................................................................................................................... 30 Appendices Appendix A: Regional Energy Management Team ............................................................................................. D-1 Appendix E: Energy Awareness Strategies

51

EA-2001: Energy Efficiency Design Standards: New Federal Commercial and Multi-Family High-Rise Residential Buildings and New Federal Low-Rise Residential Buildings  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy (DOE) is publishing this final rule to implement provisions in the Energy Conservation and Production Act (ECPA) that require DOE to update the baseline Federal energy efficiency performance standards for the construction of new Federal commercial and multi-family high-rise residential buildings. This rule updates the baseline Federal commercial standard to the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standard 90.1-2013.

52

SFSU Building Coordinators List College or Administrative Unit Location(s)  

E-Print Network [OSTI]

SFSU Building Coordinators List College or Administrative Unit Location(s) Building Coordinator81193 cathym@sfsu.edu GYM 102B Student Services Building SSB Mirel Tikkanen x53566 mtikkane@sfsu.edu SSB

53

Federal High Performance and Sustainable Buildings: Guiding Principles for the Laboratory Support Building (LSB)  

SciTech Connect (OSTI)

This report documents the federal Guiding Principles conformance effort for LSB at PNNL. The effort is part of continued progress toward a campus building inventory that is 100% compliant with the Guiding Principles. The report documentation provides a narrative of how the LSB complies with each of the Guiding Principles requirements. These narratives draw from the many sources that are explained in the text and rely on extensive data collection. The descriptions point to each of these sources, providing the reader with specific policies, procedures, and data points.

Pope, Jason E.

2014-09-01T23:59:59.000Z

54

Zarb Appointed to Lead the Federal Energy Administration | National Nuclear  

National Nuclear Security Administration (NNSA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartmentNational NuclearhasAdministration goSecurity Administration machine

55

Federal Register Notice: National Nuclear Security Administration Site-Wide  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAX POLICIES ANDIndustrialEnergy FederalFLASH 2004-12 AprilEnergyEnvironmental

56

Bosnia-Herzegovina: Trying to Build a Federal State on Paradoxes Introduction  

E-Print Network [OSTI]

1 Bosnia-Herzegovina: Trying to Build a Federal State on Paradoxes Jens Woelk Introduction The basis for federalism in Bosnia-Herzegovina1 is rather peculiar due to the unique complexity. This was to be accomplished by physical reconstruction as well as by preserving Bosnia and Herzegovina as one country

Wintner, Shuly

57

Energy Efficiency Solution for the Chet Holifield Federal Building  

SciTech Connect (OSTI)

Utility partnership upgrades energy system to help meet the General Services Administration's (GSA) energy-saving goals.

Not Available

2000-07-01T23:59:59.000Z

58

Worker Protection Program for DOE (Including the National Nuclear Security Administration) Federal Employees  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order establishes the framework for an effective worker protection program that will reduce or prevent injuries, illnesses, and accidental losses by providing Department of Energy (DOE), including National Nuclear Security Administration (NNSA), Federal workers with a safe and healthful workplace. Cancels DOE O 440.1A. Certified 6/17/2011. Canceled by DOE O 440.1B Chg 1.

2007-05-17T23:59:59.000Z

59

Federal Emergency Management Information System (FEMIS) system administration guide. Version 1.2  

SciTech Connect (OSTI)

The Federal Emergency Management Information System (FEMIS) is an emergency management planning and analysis tool that is being developed under the direction of the US Army Chemical biological Defense Command. The FEMIS System Administration Guide defines FEMIS hardware and software requirements and gives instructions for installing the FEMIS system package. System administrators, database administrators, and general users can use this guide to install, configure, and maintain the FEMIS client software package. This document provides a description of the FEMIS environment; distribution media; data, communications, and electronic mail servers; user workstations; and system management.

Burford, M.J.; Burnett, R.A.; Curtis, L.M. [and others

1996-05-01T23:59:59.000Z

60

Research Administration Discussion Group (RADG) Building Bridges to Navigate Organizational Structures  

E-Print Network [OSTI]

as individual administrators navigate within existing organizational structures to maximize efficiency Research Administration Discussion Group (RADG) Building Bridges to Navigate Organizational organizational experiences and business processes, particularly at the nexus of pre and postaward activities

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Technical Analysis: Integrating a Hydrogen Energy Station into a Federal Building  

E-Print Network [OSTI]

Technical Analysis: Integrating a Hydrogen Energy Station into a Federal Building Stefan Unnasch. Hydrogen Fueling Requirements Building hydrogen energy stations requires further efforts to reduce costs Energy Station The combined production of fuel cell power and hydrogen at the same facility

62

Using Dashboards to Improve Energy and Comfort in Federal Buildings  

E-Print Network [OSTI]

gases (GHG) or carbon footprint, and public education onand lowering the carbon footprint or GHG emissions forby reducing carbon footprint. • Compare buildings’ energy

Marini, Kyle

2011-01-01T23:59:59.000Z

63

Technical support document for the proposed Federal Commercial Building energy code  

SciTech Connect (OSTI)

This report presents the justification and technical documentation for all changes and updates made (since 1993) to the Energy Code for Commercial and High-Rise Residential Buildings, the codified version of ASHRAE/IES Standard 90.1-1989, ``Energy Efficient Design of New Buildings Except Low-Rise Residential Buildings.`` These changes and updates, which were subject to the ASHRAE addenda approval process, include Addenda b, c, d, e, g, and i. A seventh addenda, Addenda f, which has not been officially approved by ASHRAE, has been included into the proposed rule. Also included in the changes was technical work conducted to justify revisions to the 1993 DOE lighting power densities. The updated text will be reviewed by the U.S. Department of Energy (DOE) and issued as the new Federal Commercial Building Energy Code (10 CFR 434); Mandatory for New Federal Commercial and Multi-Family High Rise Residential Buildings.

Somasundaram, S.; Halverson, M.A.; Jones, C.C.; Hadley, D.L.

1995-11-01T23:59:59.000Z

64

Federally Funded Programs Related to Building Energy Use: Overlaps, Challenges, and Opportunities for Collaboration  

SciTech Connect (OSTI)

As energy efficiency in buildings continues to move from discreet technology development to an integrated systems approach, the need to understand and integrate complementary goals and targets becomes more pronounced. Whether within Department of Energy’s (DOE) Building Technologies Program (BTP), across the Office of Energy Efficiency and Renewable Energy (EERE), or throughout DOE and the Federal government, mutual gains and collaboration synergies exist that are not easily achieved because of organizational and time constraints. There also cases where federal agencies may be addressing similar issues, but with different (and sometimes conflicting) outcomes in mind. This report conducts a comprehensive inventory across all EERE and other relevant Federal agencies of potential activities with synergistic benefits. A taxonomy of activities with potential interdependencies is presented. The report identifies a number of federal program objectives, products, and plans related to building energy efficiency and characterizes the current structure and interactions related to these plans and programs. Areas where overlap occurs are identified as are the challenges of addressing issues related to overlapping goals and programs. Based on the input gathered from various sources, including 20 separate interviews with federal agency staff and contractor staff supporting buildings programs, this study identifies a number of synergistic opportunities and makes recommends a number of areas where further collaboration could be beneficial.

Cort, Katherine A.; Butner, Ryan S.; Hostick, Donna J.

2010-10-01T23:59:59.000Z

65

Low-Energy Building Design Guidelines: Energy-Efficient Design for New Federal Facilities  

SciTech Connect (OSTI)

This guidebook has been prepared primarily for Federal energy managers to provide practical information for applying the principles of low-energy, whole-building design in new Federal buildings. An important objective of this guidebook is to teach energy managers how to be advocates for renewable energy and energy-efficient technologies, and how to apply specific strategies during each phase of a given project's time line. These key action items are broken out by phase and appear in abbreviated form in this guidebook.

Zachman, W.; Carlisle, N.

2001-07-19T23:59:59.000Z

66

Federal, state and utility roles in reducing new building greenhouse gas emissions  

SciTech Connect (OSTI)

This paper will explore the role of implementation of building energy codes and standards in reducing US greenhouse gas emissions. It will discuss the role of utilities in supporting the US Department of Energy (DOE) and the Environmental Protection Agency in improving the efficiency of new buildings. The paper will summarize Federal policies and programs that improve code compliance and increase overall greenhouse gas emission reductions. Finally, the paper will discuss the role of code compliance and the energy and greenhouse gas emission reductions that have been realized from various Federal, State and utility programs that enhance compliance.

Johnson, J.A.; Shankle, D. [Pacific Northwest Lab., Richland, WA (United States); Boulin, J. [USDOE, Washington, DC (United States)

1995-03-01T23:59:59.000Z

67

EA-1872: Energy Efficiency and Sustainable Design Standards for New Federal Buildings  

Broader source: Energy.gov [DOE]

This EA evaluated the environmental impacts of a proposal to amend the current rule for commercial and high-rise multi-family residential buildings, 10 CFR 433 “Energy Efficiency Standards for New Federal Commercial and High-Rise Multi-Family Residential Buildings,” to replace ASHRAE Standard 90.1-2004 with the more stringent ASHRAE Standard 90.1-2007, incorporated by reference. This EA also evaluated the environmental impacts with regard to low-rise residential buildings; this rulemaking updated 10 CFR 435 Subpart A, “Energy Efficiency Standards for New Federal Residential Low-Rise Residential Buildings,” to replace the International Energy Conservation Code (IECC) 2004 with the more stringent IECC 2009, incorporated by reference. This EA was completed as DOE/EA-1871.

68

Federal Leadership in High Performance and Sustainable Buildings Memorandum  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAX POLICIES ANDIndustrialEnergy Federal EfficiencyReporting &Federalof

69

Federal Leadership in High Performance and Sustainable Buildings Memorandum  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAX POLICIES ANDIndustrialEnergy Federal EfficiencyReporting &Federalofof

70

Federal Emergency Management Information System (FEMIS) system administration guide. Version 1.3  

SciTech Connect (OSTI)

The Federal Emergency Management Information System (FEMIS) is an emergency management planning and analysis tool that was developed by the (Pacific Northwest National Laboratory) (PNNL) under the direction of the U.S. Army Chemical Biological Defense Command. The FEMIS System Administration Guide defines FEMIS hardware and software requirements and gives instructions for installing the FEMIS software package. 91 This document also contains information on the following: software installation for the FEMIS data servers, communication server, mail server, and the emergency management workstations; distribution media loading and FEMIS installation validation and troubleshooting; and system management of FEMIS users, login, privileges, and usage. The system administration utilities (tools), available in the FEMIS client software, are described for user accounts and site profile. This document also describes the installation and use of system and database administration utilities that will assist in keeping the FEMIS system running in an operational environment.

Burford, M.J.; Burnett, R.A.; Downing, T.R. [and others

1996-12-01T23:59:59.000Z

71

Analyzing Two Federal Building-Integrated Photovoltaic Projects Using ENERGY-10 Simulations: Preprint  

SciTech Connect (OSTI)

A new version of the ENERGY-10 computer program simulates the performance of photovoltaic systems, in addition to presenting a wide range of opportunities to improve energy efficiency in buildings. This paper describes two test cases in which the beta release of ENERGY-10 version 1.4 was used to evaluate energy efficiency and building-integrated photovoltaics (BIPV) for two Federal building projects: an office and laboratory building at the Smithsonian Astrophysical Laboratory in Hilo, Hawaii, and housing for visiting scientists at the Smithsonian Environmental Research Center in Edgewater, Maryland. The paper describes the capabilities of the software, the method in which ENERGY-10 was used to assist in the design, and the results. ENERGY-10 appears to be an effective tool for evaluating BIPV options early in the building design process. By simulating both the building electrical load and simultaneous PV performance for each hour of the year, the ENERGY-10 program facilitates a highly accurate, integrated analysis.

Walker, A.; Balcomb, D.; Weaver, N.; Kiss, G.; Becker-Humphry, M.

2002-03-01T23:59:59.000Z

72

Building a Global Federation System for Climate Change Research: The Earth System Grid Center for Enabling  

E-Print Network [OSTI]

Building a Global Federation System for Climate Change Research: The Earth System Grid Center for Enabling Technologies (ESG-CET) The Earth System Grid Center for Enabling Technologies Team: R Ananthakrishnan1 , D E Bernholdt7,9 , S Bharathi8 , D Brown5 , M Chen7 , A L Chervenak8 , L Cinquini5 , R Drach3

Chervenak, Ann

73

Better Buildings Workforce Guidelines Energy Manager and Federal Facility Manager  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd: ScopeDepartment1, 2011 BetterOctober25,CallTheState ofBuildings

74

Better Buildings Federal Award Application 2013 | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergy Cooperation |South42.2 (April 2012)TieEnergyExecutiveBethel ValleyBetter BuildingsBetter

75

EA-1926: Energy Efficiency Design Standards for New Federal Low-Rise Residential Buildings (RIN# 1904-AC61)  

Broader source: Energy.gov [DOE]

This EA will evaluate the potential environmental impacts of implementing the provisions in the Energy Conservation and Production Act (ECPA) that require DOE to update the baseline Federal energy efficiency performance standards for the construction of new Federal buildings, including low-rise residential buildings.

76

Obama Administration Announces New Partners Join the Better Buildings...  

Office of Environmental Management (EM)

buildings, which allows them to offer financing on energy efficiency, renewable energy, and water conservation improvements. Samas Capital uses the capital markets for...

77

Obama Administration Expands Better Buildings Challenge to Multifamily...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

utilities and manufacturers, we can continue this progress - cutting carbon pollution, fostering economic growth and building a cleaner, more sustainable energy future."...

78

Simulation-assisted evaluation of potential energy savings: Application to an administrative building in France  

E-Print Network [OSTI]

The case study presented here falls within a project of feasibility studies to improve the energy efficiency, the carbon footprint and the environmental impacts of several administrative buildings in France. The first part of the paper briefly...

Randaxhe, F.; Bertagnolio, S.; Lemort, V.

2012-01-01T23:59:59.000Z

79

Targeted Energy Efficiency Expert Evaluation (E4) Report: Iowa City Federal Building and U.S. Post Office, Iowa City, IA  

SciTech Connect (OSTI)

Final report summarizing Targeted E4 measures and energy savings analysis for the Iowa City Federal Building and Post Office.

Goddard, James K.; Fernandez, Nicholas; Underhill, Ronald M.; Gowri, Krishnan

2013-03-01T23:59:59.000Z

80

Federal Emergency Management Information System (FEMIS) system administration guide. Version 1.4  

SciTech Connect (OSTI)

The Federal Emergency Management Information System (FEMIS) is an emergency management planning and analysis tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the US Army Chemical Biological Defense Command. The FEMIS System Administration Guide defines FEMIS hardware and software requirements and gives instructions for installing the FEMIS software package. This document also contains information on the following: software installation for the FEMIS data servers, communication server, mail server, and the emergency management workstations; distribution media loading and FEMIS installation validation and troubleshooting; and system management of FEMIS users, login privileges, and usage. The system administration utilities (tools), available in the FEMIS client software, are described for user accounts and site profile. This document also describes the installation and use of system and database administration utilities that will assist in keeping the FEMIS system running in an operational environment. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are connected via a local area network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via telecommunications links.

Arp, J.A.; Burnett, R.A.; Downing, T.R. [and others] [and others

1997-11-21T23:59:59.000Z

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

EA-1463: 10 CFR 433: Energy Efficiency Standards for New Federal Commercial and High-Rise Multi-Family Residential Buildings and 10 CFR 435: Energy Efficiency Standards for New Federal Residential Low-Rise Residential Buildings  

Broader source: Energy.gov [DOE]

The EA examines the potential environmental impacts of the Final Rule on building habitability and the outdoor environment. To identify the potential environmental impacts that may result from implementing the Final Rule for new Federal commercial and residential buildings, DOE compared the Final Rule with the “no-action alternative” of using the current Federal standards – 10 CFR Part 434 and 10 CFR Part 435 Subpart C (referred to as the “no-action alternative”).

82

Buildings Energy Data Book: 4.1 Federal Buildings Energy Consumption  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.414663 Federal

83

Buildings Energy Data Book: 4.1 Federal Buildings Energy Consumption  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.414663 Federal4

84

Buildings Energy Data Book: 4.2 Federal Buildings and Facilities Characteristics  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.414663 Federal42

85

Buildings Energy Data Book: 4.3 Federal Buildings and Facilities Expenditures  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.414663 Federal421 FY

86

Buildings Energy Data Book: 4.3 Federal Buildings and Facilities Expenditures  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.414663 Federal421

87

Buildings Energy Data Book: 4.3 Federal Buildings and Facilities Expenditures  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.414663 Federal4213

88

Buildings Energy Data Book: 4.4 Legislation Affecting Energy Consumption of Federal Buildings and Facilities  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.414663 Federal42131

89

Buildings Energy Data Book: 4.4 Legislation Affecting Energy Consumption of Federal Buildings and Facilities  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.414663 Federal421312

90

Federal Emergency Management Information System (FEMIS) System Administration Guide for FEMIS Version 1.4.6  

SciTech Connect (OSTI)

The Federal Emergency Management Information System (FEMIS) is an emergency management planning and response tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the U.S. Army Chemical Biological Defense Command. The FEMIS System Administration Guide provides information necessary for the system administrator to maintain the FEMIS system. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are corrected via a local area network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via a Wide Area Network (WAN). Thus, FEMIS is an integrated software product that resides on client/server computer architecture. The main body of FEMIS software, referred to as the FEMIS Application Software, resides on the PC client(s) and is directly accessible to emergency management personnel. The remainder of the FEMIS software, referred to as the FEMIS Support Software, resides on the UNIX server. The Support Software provides the communication data distribution and notification functionality necessary to operate FEMIS in a networked, client/server environment.

Arp, J.A.; Bower, J.C.; Burnett, R.A.; Carter, R.J.; Downing, T.R.; Fangman, P.M.; Gerhardstein, L.H.; Homer, B.J.; Johnson, D.M.; Johnson, R.L.; Johnson, S.M.; Loveall, R.M.; Martin, T.J.; Millard, W.D.; Schulze, S.A.; Stoops, L.R.; Tzemos, S.; Wood, B.M.

1999-06-29T23:59:59.000Z

91

Federal Emergency Management Information System (FEMIS) system administration guide, version 1.4.5  

SciTech Connect (OSTI)

The Federal Emergency Management Information Systems (FEMIS) is an emergency management planning and response tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the US Army Chemical Biological Defense Command. The FEMIS System Administration Guide provides information necessary for the system administrator to maintain the FEMIS system. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are connected via a local area network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via a Wide Area Network (WAN). Thus, FEMIS is an integrated software product that resides on client/server computer architecture. The main body of FEMIS software, referred to as the FEMIS Application Software, resides on the PC client(s) and is directly accessible to emergency management personnel. The remainder of the FEMIS software, referred to as the FEMIS Support Software, resides on the UNIX server. The Support Software provides the communication, data distribution, and notification functionality necessary to operate FEMIS in a networked, client/server environment. The UNIX server provides an Oracle relational database management system (RDBMS) services, ARC/INFO GIS (optional) capabilities, and basic file management services. PNNL developed utilities that reside on the server include the Notification Service, the Command Service that executes the evacuation model, and AutoRecovery. To operate FEMIS, the Application Software must have access to a site specific FEMIS emergency management database. Data that pertains to an individual EOC`s jurisdiction is stored on the EOC`s local server. Information that needs to be accessible to all EOCs is automatically distributed by the FEMIS database to the other EOCs at the site.

Arp, J.A.; Burnett, R.A.; Carter, R.J. [and others

1998-06-26T23:59:59.000Z

92

Wood Pellet-Fired Biomass Boiler Project at the Ketchikan Federal Building  

SciTech Connect (OSTI)

Biomass boiler systems have existed for many years, but the technology has advanced in recent decades and can now provide automated and efficient operation for a relatively modest investment. Key advances in system monitoring and control allow for lower operating costs, since the control systems run all aspects of the boiler, including feed, load reduction and even tube cleaning. These advances have made such systems economical on a small scale in situations where inexpensive fuels like natural gas are not available. This creates an opportunity for building operators in remote, cold-climate locations to reduce the use of expensive fuels for heating buildings. GSA Region 10 installed the system at the federal building in Ketchikan, Alaska and submitted the project to the Green Proving Ground (GPG) program. GSA's GPG program contracted with the National Renewable Energy Laboratory (NREL) to assess the installation and the technology. The system serves as a demonstration to assess actual system efficiencies, as well as operating characteristics and financial benefits. In addition to installation and operational issues, the project team/researchers examined other issues, including fuel transportation costs, building energy savings, and overall economics.

Tomberlin, G.

2014-06-01T23:59:59.000Z

93

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

metrics for sustainable building design. National ResearchJ. 2007. Sustainable Construction: Green Building Design anddesign strategies implemented in buildings promoted as “green,” “sustainable,”

Konis, Kyle Stas

2011-01-01T23:59:59.000Z

94

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

metrics for sustainable building design. National ResearchJ. 2007. Sustainable Construction: Green Building Design anddesign strategies implemented in buildings promoted as “green,” “sustainable,”

Konis, Kyle Stas

2012-01-01T23:59:59.000Z

95

Federal Emergency Management Information System (FEMIS) System Administration Guide for FEMIS Version 1.4.6  

SciTech Connect (OSTI)

The FEMIS System Administration Guide provides information on FEMIS System Administrator activities as well as the utilities that are included with FEMIS.

Arp, Jonathan A.; Bower, John C.; Burnett, Robert A.; Carter, Richard J.; Downing, Timothy R.; Fangman, Patricia M.; Gerhardstein, Lawrence H.; Homer, Brian J.; Johnson, Daniel M.; Johnson, Ranata L.; Johnson, Sharon M.; Loveall, Robert M.; Martin, Tonya J.; Millard, W. David; Schulze, Stacy A.; Stoops, Lamar R.; Tzemos, Spyridon; Wood, Blanche M.

1999-06-24T23:59:59.000Z

96

Federal Emergency Management Information System (FEMIS) System Administration Guide Version 1.5.3  

SciTech Connect (OSTI)

The FEMIS System Administration Guide provides information on FEMIS System Administrator activities as well as the utilities that are included with FEMIS.

Burnett, Robert A.; Carter, Richard J.; Downing, Timothy R.; Homer, Brian J.; Holter, Nancy A.; Johnson, Daniel M.; Johnson, Ranata L.; Johnson, Sharon M.; Loveall, Robert M.; Schulze, Stacy A.; Sivaraman, Chitra; Stephan, Alex J.; Stoops, LaMar R.; Wood, Blanche M.

2002-11-20T23:59:59.000Z

97

DEMONSTRATION OF THE DOE INTERIM ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL RESIDENTIAL BUILDINGS  

SciTech Connect (OSTI)

In accordance with federal legislation, the U.S. Department of Energy (DOE) has sponsored a study to demonstrate use of its Interim Energy Conservation Standards for New Federal Residential Buildings. The demonstration study was conducted by DOE and the Pacific Northwest Laboratory (PNL). The demonstration is the second step in a three-step process: I) development of interim standards, 2) demonstration of the interim standards, and 3) development of final standards. The standards are mandatory for federal agency housing procurements. Nevertheless, PNL found at the start of the demonstration that agency use of the interim standards had been minimal. The purpose of the standards is to improve the energy efficiency of federal housing and increase the use of nondepletable energy sources. In accordance with the legislation, the standards were to be performance-based rather than prescribing specific energy conservation measures. To fulfill this aspect of the legislation, the standards use a computer software program called COSTSAFR which generates a point system that individualizes the standards to specific projects based on climate, housing type, and fuel costs. The standards generate minimum energy-efficiency requirements by applying the life-cycle cost methodology developed for federal projects. For the demonstration, PNL and DOE chose five federal agency housing projects which had been built in diverse geographic and climate regions. Participating agencies were the Air Force, the Army (which provided two case studies), the Navy, and the Department of Health and Human Services. PNL worked with agency housing procurement officials and designers/architects to hypothetically apply the interim standards to the procurement and design of each housing project. The demonstration started at the point in the project where agencies would establish their energyefficiency requirements for the project and followed the procurement process through the designers' use of the point system to develop a design which would comply with the standards. PNL conducted extensive interviews with the federal agencies and design contractors to determine what impacts the standards would have on the existing agency procurement process as well as on designers. Overall, PNL found that the interim standards met the basic intent of the law. Specific actions were identified, however, that DOE could take to improve the standards and encourage the agencies to implement them. Agency personnel found the minimum efficiency levels established by the standards to be lower than expected, and lower than their existing requirements. Generally, this was because the standards factor in fuel costs, as well as energy savings due to various conservation measures such as insulation, when they determine the minimum efficiency levels required. The demonstration showed that federal agencies often pay low prices for heating fuel and electricity; these lower costs "tipped the scales," allowing designers to meet the efficiency target with designs that were relatively inefficient. It appeared, however, that the low prices paid by agencies directly to suppliers did not capture the agencies' full costs of providing energy, such as the costs of distribution and storage. Agency personnel expressed some concern about the standards' ability to incorporate new energy-efficient technologies and renewable resource technologies like solar heating systems. An alternative compliance procedure was developed to incorporate new technologies; however, demonstration participants said the procedure was not well documented and was difficult and time consuming to use. Despite these concerns, most agency personnel thought that the standards would fit into current procurement procedures with no big changes or cost increases. Many said use of the standards would decrease the time and effort they now spend to establish energy-efficiency requirements and to confirm that proposed designs comply. Personnel praised the software and documentation for being easy to use and providing energ

Lee, A. D.; Baechler, H. C.; Di Massa, F. V.; Lucas, R. G.; Shankle, D. L.

1992-01-01T23:59:59.000Z

98

Analysis of federal policy options for improving US lighting energy efficiency: Commercial and residential buildings  

SciTech Connect (OSTI)

The US Department of Energy (DOE) has recognized the opportunity to achieve energy, economic, and environmental benefits by promoting energy-efficient lighting through federal policies, including lighting standards, financial incentives, and information programs. To assist in this process, the Office of Conservation and Renewable Energy`s Office of Codes and Standards invited Lawrence Berkeley Laboratory to assess prospective national impacts for a variety of policy options. Some progress has already been made in developing lighting policies at both the federal and state levels. The US DOE`s Office of Building Technologies has evaluated lighting efficiency incentives as part of its analysis for the National Energy Strategy. Fluorescent and incandescent lamp standards are included in the national Energy Policy Act of 1992 (P.L. 102-486, October 24, 1992). A few states have analyzed or implemented lamp and luminaire standards. Many policy-related issues merit further investigation. For example, there is considerable debate over issues such as mandatory or voluntary standards versus component labeling and other education-oriented strategies. Several different technologies are involved that interact with each other-lamps (incandescent, compact fluorescent, and HID), ballasts (for fluorescent and HID lamps), and fixtures with reflectors and lenses. Control systems and operation patterns must also be considered (timers, automated dimming, or occupancy sensors). Lighting applications are diverse, ranging from offices, restaurants, hallways, hospital operating rooms, to exterior lights. Lighting energy use influences heating and cooling requirements in buildings. Successful lighting system design must also address interactions between architectural design elements and daylighting availability. Proper system installation and ongoing operation and maintenance are crucial. The economic aspects of the preceding points must also be considered for policy making.

Atkinson, B.A.; McMahon, J.E.; Mills, E.; Chan, P.; Chan, T.W.; Eto, J.H.; Jennings, J.D.; Koomey, J.G.; Lo, K.W.; Lecar, M.; Price, L.; Rubinstein, F.; Sezgen, O.; Wenzel, T.

1992-12-01T23:59:59.000Z

99

Analysis of federal policy options for improving US lighting energy efficiency: Commercial and residential buildings  

SciTech Connect (OSTI)

The US Department of Energy (DOE) has recognized the opportunity to achieve energy, economic, and environmental benefits by promoting energy-efficient lighting through federal policies, including lighting standards, financial incentives, and information programs. To assist in this process, the Office of Conservation and Renewable Energy's Office of Codes and Standards invited Lawrence Berkeley Laboratory to assess prospective national impacts for a variety of policy options. Some progress has already been made in developing lighting policies at both the federal and state levels. The US DOE's Office of Building Technologies has evaluated lighting efficiency incentives as part of its analysis for the National Energy Strategy. Fluorescent and incandescent lamp standards are included in the national Energy Policy Act of 1992 (P.L. 102-486, October 24, 1992). A few states have analyzed or implemented lamp and luminaire standards. Many policy-related issues merit further investigation. For example, there is considerable debate over issues such as mandatory or voluntary standards versus component labeling and other education-oriented strategies. Several different technologies are involved that interact with each other-lamps (incandescent, compact fluorescent, and HID), ballasts (for fluorescent and HID lamps), and fixtures with reflectors and lenses. Control systems and operation patterns must also be considered (timers, automated dimming, or occupancy sensors). Lighting applications are diverse, ranging from offices, restaurants, hallways, hospital operating rooms, to exterior lights. Lighting energy use influences heating and cooling requirements in buildings. Successful lighting system design must also address interactions between architectural design elements and daylighting availability. Proper system installation and ongoing operation and maintenance are crucial. The economic aspects of the preceding points must also be considered for policy making.

Atkinson, B.A.; McMahon, J.E.; Mills, E.; Chan, P.; Chan, T.W.; Eto, J.H.; Jennings, J.D.; Koomey, J.G.; Lo, K.W.; Lecar, M.; Price, L.; Rubinstein, F.; Sezgen, O.; Wenzel, T.

1992-12-01T23:59:59.000Z

100

DEMONSTRATION OF THE DOE INTERIM ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL RESIDENTIAL BUILDINGS: EXECUTIVE SUMMARY  

SciTech Connect (OSTI)

In accordance with federal legislation, the U.S. Department of Energy (DOE) bas conducted a project to demonstrate use of its Interim Energy Conservation Standards for New Federal Residential Buildings. The demonstration is the second step in a three-step process: development of interim standards, demonstration of the interim standards, and development of final standards. Pacific Northwest Laboratory (PNL) collected information from the demonstration project and prepared this report under a contract with DOE. The purpose of the standards is to improve the energy efficiency of federal housing and increase the use of nondepletable energy sources. In accordance with the legislation, the standards were to be performance-based rather than prescribing specific energy conservation measures. The standards use a computer software program called COSTSAFR which individualizes the standards based on climate, housing type, and fuel costs. The standards generate minimum energy-efficiency requirements by applying the life-cycle cost methodology developed for federal projects, For the demonstration, the DOE chose live federal agency housing projects: four military housing projects and one project for the Department of Health and Human Services. DOE and PNL worked with agency housing procurement officials and designers/architects to hypothetically apply the interim standards to each housing project. PNL conducted extensive interviews with the federal agencies and design contractors to determine what impacts the standards would have on the existing agency procurement process as well as on designers. Overall, PNL found that the interim standards met the basic intent of the law. Specific actions were identified, however, that DOE could take to improve the standards and encourage the agencies to implement them. Agency personnel and designers expressed similar concerns about the standards: the minimum efficiency levels established by the standards were lower than expected and the standards did not provide an easy way to incorporate new energy-efficient and renewable resource tec.:hnolog:ies like solar heating systems. Agency personnel said the standards would fit into current procurement procedures with no big changes or cost increases, Many said the standards would decrease the time and effort they now spend to establish energy-efficiency requirements and to confirm that proposed designs comply with those requirements. Agency personnel praised the software and documentation for being easy to use and providing energy-efficiency requirements in energy dollars. Housing designers agreed that the DOE standards were easy to use to determine that their designs meet energy-efficiency goals. Many felt the information provided by the standards could be useful in the design process. Based on the demonstration, PNL recommends establishing task forces that will actively involve agency personnel and others in future revisions and development of the final standards. PNL also recommends that DOE and federal agencies investigate the use of market fuel and energy prices in the standards, rather than the prices paid by the agencies, to better reflect actual costs. A number of recommendations are made for improving communications between DOE and the users of the standards and for enhancing tools to implement the standards. Several recommendations are made for increasing the number of renewable resources that are included in the standards. Finally, PNL recommends ongoing monitoring activities to continue to identify ways in which the standards can be improved.

Lee, A. D.; Baechler, M / C.; Di Massa, F. V.; Lucas, R. G.; Shankle, D. L.

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

Annex 29, Daylight in Buildings. October, 1997. Atif. M.R.case studies. Energy and Buildings 35 441-461. Attmann,George. 2010. Sustainable Buildings in Practice: What the

Konis, Kyle Stas

2012-01-01T23:59:59.000Z

102

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

performance,” or “energy efficient” design. This approach isstandards for the design of energy efficient buildings (standards for the design of energy efficient buildings (e.g.

Konis, Kyle Stas

2012-01-01T23:59:59.000Z

103

Hydrogen and Fuel Cell Transit Bus Evaluations: Joint Evaluation Plan for the U.S. Department of Energy and the Federal Transit Administration (Report and Appendix)  

SciTech Connect (OSTI)

This document describes the hydrogen transit bus evaluations performed by the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) and the U.S. Department of Transportation's Federal Transit Administration (FTA).

Eudy, L.; Chandler, K.

2008-05-01T23:59:59.000Z

104

Radiation control coatings installed on federal buildings at Tyndall Air Force Base. Volume 2: Long-term monitoring and modeling  

SciTech Connect (OSTI)

The US Department of Energy`s (DOE`s) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the federal sector. One such effort, the New Technology Demonstration Program (NTDP), seeks to evaluate new energy-saving US technologies and secure their more timely adoption by the US government. Through a partnership with a federal site, the utility serving the site, a manufacturer of an energy-related technology, and other organizations associated with these interests, DOE can evaluate a new technology. The results of the program give federal agency decision makers more hands-on information with which to validate a decision to utilize a new technology in their facilities. This is the second volume of a two-volume report that describes the effects of radiation control coatings installed on federal buildings at Tyndall Air Force Base (AFB) in Florida by ThermShield International. ORNL`s Buildings Technology Center (BTC) was assigned the responsibility for gathering, analyzing, and reporting on the data to describe the effects of the coatings. The first volume described the monitoring plan and its implementation, the results of pre-coating monitoring, the coating installation, results from fresh coatings compared to pre-coating results, and a plan to decommission the monitoring equipment. This second volume updates and completes the presentation of data to compare performance of fresh coatings with weathered coatings.

Petrie, T.W.; Childs, P.W.

1998-06-01T23:59:59.000Z

105

Demonstration of the Whole-Building Diagnostician for the Federal Building and U.S. Courthouse at Milwaukee, Wisconsin, and for the University of Wisconsin at Madison  

SciTech Connect (OSTI)

In an effort to expand the energy savings programs within the State, the Wisconsin Division of Energy obtained funding through the Federal Energy Management Program (FEMP), with additional funding assistance through the Rebuild America Program (RBA) to install the Whole Building Diagnostician (WBD) software program as a test bed project in two of the State’s facilities in Wisconsin. This report discusses the results of this effort.

Bauman, Nathan N.; Hail, John C.

2003-12-30T23:59:59.000Z

106

Worker Protection Program for DOE (Including the National Nuclear Security Administration) Federal Employees  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order establishes the framework for an effective worker protection program that will reduce or prevent injuries, illnesses, and accidental losses by providing DOE and NNSA Federal workers with a safe and healthful workplace. Chg 1 dated 8-21-12. Cancels DOE M 440.1-1A. Admin Chg 1, dated 3-14-13.

2007-05-17T23:59:59.000Z

107

EA-1918: Final Rule, 10 CFR 433, "Energy Efficiency Standards for New Federal Commercial and MultiFamily High-Rise Residential Buildings" RIN 1904-AC60  

Broader source: Energy.gov [DOE]

This EA evaluates the environmental impacts of implementing provisions in the Energy Conservation and Production Act (ECPA) that require DOE to update the baseline Federal energy efficiency performance standards for the construction of new Federal buildings, including commercial and multi-family high-rise residential buildings. This EA addresses Federal commercial standard to the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standard 90.1-2010. The Final Rule was published in the Federal Register on July 9, 2013, 78 FR 40945.

108

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

of Task 21 / Annex 29, Daylight in Buildings. October, 1997.Energy performance of daylight-linked automatic lightingField Commissioning of a daylight-dimming lighting system.

Konis, Kyle Stas

2012-01-01T23:59:59.000Z

109

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

of Task 21 / Annex 29, Daylight in Buildings. October, 1997.Energy performance of daylight-linked automatic lightingBegemann, G. et al. (1997). Daylight, artificial light and

Konis, Kyle Stas

2011-01-01T23:59:59.000Z

110

Worker Protection Program for DOE (Including the National Nuclear Security Administration) Federal Employees  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order establishes the framework for an effective worker protection program that will reduce or prevent injuries, illnesses, and accidental losses by providing DOE and NNSA Federal workers with a safe and healthful workplace. Chg 1 dated 8-21-12, cancels DOE M 440.1-1A. Admin Chg 1, dated 3-14-13, cancels DOE O 440.1B Chg 1.

2007-05-17T23:59:59.000Z

111

EA-1871: Environmental Assessment for Final Rule, 10 CFR 433, “EE Standards for New Federal Commercial and High-Rise Multi-Family Residential Buildings” and 10 CFR 435, “EE Standards for New Federal Residential Low-Rise Residential Buildings"  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy (DOE) has prepared this Environmental Assessment (EA) for DOE‘s Final Rule, 10 CFR 433, ?Energy Efficiency Standards for New Federal Commercial and High-Rise Multi-Family Residential Buildings? and 10 CFR 435, ?Energy Efficiency Standards for New Federal Residential Low-Rise Residential Buildings? Baseline Standards Update. The final rule updates the baseline standards in 10 CFR 433 and 10 CFR 435 to the latest private sector standards based on the cost-effectiveness of the latest private sector standards and DOE‘s determination that energy efficiency has been improved in these codes as required by 42 U.S.C 6831 et seq. DOE is issuing its final determinations on American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2007 (ASHRAE 2007) and the International Code Council‘s 2009 International Energy Conservation Code (IECC) in the same edition of the Federal Register as this final rule.

112

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

integrated,” and “green” design 11 Figure 2.1 Environmental control functions performed by the buildingbuilding as a model of “high performance,” “integrated,” and “green” design.Design and Evaluation of integrated envelope and lighting control strategies for commercial buildings.

Konis, Kyle Stas

2012-01-01T23:59:59.000Z

113

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

integrated,” and “green” design 11 Figure 2.1 Environmental control functions performed by the buildingbuilding as a model of “high performance,” “integrated,” and “green” design.Design and Evaluation of integrated envelope and lighting control strategies for commercial buildings.

Konis, Kyle Stas

2011-01-01T23:59:59.000Z

114

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

the integration of architecture and sustainable engineeringthe integration of architecture and sustainable engineeringArchitecture University of California, Berkeley Professor Charles C. Benton, Chair Commercial office buildings promoted as “sustainable,” “

Konis, Kyle Stas

2011-01-01T23:59:59.000Z

115

41.99.99.M0.01 Building Proctor and Facility Coordinator Positions Page 1 of 3 STANDARD ADMINISTRATIVE PROCEDURE  

E-Print Network [OSTI]

41.99.99.M0.01 Building Proctor and Facility Coordinator Positions Page 1 of 3 STANDARD ADMINISTRATIVE PROCEDURE 41.99.99.M0.01 Building Proctor and Facility Coordinator Positions Approved November 5, 2008 Revised June 6, 2012 Next Scheduled Review: June 6, 2015 Standard Administrative Procedure

116

Construction cost impact analysis of the U.S. Department of Energy mandatory performance standards for new federal commercial and multi-family, high-rise residential buildings  

SciTech Connect (OSTI)

In accordance with federal legislation, the U.S. Department of Energy (DOE) has conducted a project to demonstrate use of its Energy Conservation Voluntary Performance Standards for Commercial and Multi-Family High-Rise Residential Buildings; Mandatory for New Federal Buildings; Interim Rule (referred to in this report as DOE-1993). A key requisite of the legislation requires DOE to develop commercial building energy standards that are cost effective. During the demonstration project, DOE specifically addressed this issue by assessing the impacts of the standards on (1) construction costs, (2) builders (and especially small builders) of multi-family, high-rise buildings, and (3) the ability of low-to moderate-income persons to purchase or rent units in such buildings. This document reports on this project.

Di Massa, F.V.; Hadley, D.L.; Halverson, M.A.

1993-12-01T23:59:59.000Z

117

Energy-Smart Building Choices: How School Administrators and Board Members Are Improving Learning and Saving Money (Revision)  

SciTech Connect (OSTI)

Most school administrators and board members today must perform a tough juggling act. You're challenged to fulfill increasingly complex educational missions, meet rising community expectations, and serve growing student populations all with constrained operating budgets. As districts consider renovating their facilities or building new schools, many have found that smart energy choices can have lasting benefits for their schools, their communities, and the environment.

Not Available

2002-02-01T23:59:59.000Z

118

University Buildings Landmark Buildings  

E-Print Network [OSTI]

KEY University Buildings Landmark Buildings The Lanyon Building Roads Footpath Cafe University Engineering N Medicine, Dentistry and Biomedical Sciences P Music and Sonic Arts Q Nursing and Midwifery R and Student Affairs 3 Administration Building 32 Ashby Building 27 Belfast City Hospital 28 Bernard Crossland

Paxton, Anthony T.

119

Deploying Federal Talent to Build the Future STEM Workforce | Department of  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelinesProvedDecember 2005Department ofDOE AccidentWasteZoneEnergy Deploying Federal Talent

120

Site selection and preliminary evaluation of potential solar-industrial-process-heat applications for federal buildings in Texas  

SciTech Connect (OSTI)

The potential for solr process heat applications for federal buildings in Texas is assessed. The three sites considered are Reese Air Force Base, Lubbock; Fort Bliss, El Paso; and Dyess Air Force Base, Abilene. The application at Lubbock is an electroplating and descaling facility for aircraft maintenance. The one at El Paso is a laundry facility. The Abilene system would use solar heat to preheat boiler feedwater makeup for the base hospital boiler plant. The Lubbock site is found to be the most appropriate one for a demonstration plant, with the Abilene site as an alternate. The processes at each site are described. A preliminary evaluation of the potential contribution by solar energy to the electroplating facility at Reese AFB is included. (LEW)

Branz, M A

1980-09-30T23:59:59.000Z

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Quality site seasonal report, Tucson Job Corps Center, SFBP (Solar in Federal Buildings Program) 1751, November 1984 through July 1985  

SciTech Connect (OSTI)

The active solar Domestic Hot Water (DHW) system at the Tucson Job Corps Center was designed and constructed as part of the Solar in Federal Buildings Program (SFBP). This retrofitted system is one of eight of the systems in the SFBP selected for quality monitoring. The purpose of this monitoring effort is to document the performance of quality state-of-the-art solar systems in large Federal buildings. The systems are unique prototypes. Design errors and system faults discovered during the monitoring period could not always be corrected. Therefore, the aggregated overall performance is often considerably below what might be expected had similar systems been constructed consecutively with each repetition incorporating corrections and improvements. The solar collector system is installed on a two story dormitory at the Job Corps Center. The solar system preheats hot water for about two hundred students. The solar system provided about 50% of the energy needed for water heating in the winter and nearly 100% of the water heating needs in the summer. There are about 70,000 gallons of water used per month. There are seventy-nine L.O.F. panels or 1659 square feet of collectors (1764 square feet before freeze damage occurred) mounted in two rows on the south facing roof. Collected solar energy is stored in the 2200-gallon storage tank. The control system is by Johnson Controls. City water is piped directly to the storage tank and is circulated in the collectors. Freeze protection is provided by recirculation of storage water. There is an auxiliary gas fired boiler and 750 gallon DHW storage tank to provide backup for the solar system. Highlights of the performance monitoring from the solar collection system at the Tucson Job Corps Center during the November 1984 through July 1985 monitoring period are presented in this report.

Logee, T.L.

1987-10-15T23:59:59.000Z

122

Federal Aviation Administration 1  

E-Print Network [OSTI]

to the extent necessary, to ensure compliance with international obligations of the United States and to protect Reconciliation Act of 1990, Public Law 101-508, Title IX, Aviation Safety and Capacity Expansion Act. · What investments in such initiatives. · Improve Space System Development and Procurement. · Strengthen Interagency

Waliser, Duane E.

123

EA-0513: Approaches for Acquiring Energy Savings in Commercial Sector Buildings, Bonneville Power Administration  

Broader source: Energy.gov [DOE]

This EA evaluates the environmental impacts of a proposal for DOE's Bonneville Power Administration to use several diverse approaches to purchase or acquire energy savings from commercial sector...

124

Report: President's Energy Efficiency Contracting for Federal...  

Broader source: Energy.gov (indexed) [DOE]

Report: President's Energy Efficiency Contracting for Federal Buildings a Success Report: President's Energy Efficiency Contracting for Federal Buildings a Success January 8, 2014...

125

Off-Highway Gasoline Consuption Estimation Models Used in the Federal Highway Administration Attribution Process: 2008 Updates  

SciTech Connect (OSTI)

This report is designed to document the analysis process and estimation models currently used by the Federal Highway Administration (FHWA) to estimate the off-highway gasoline consumption and public sector fuel consumption. An overview of the entire FHWA attribution process is provided along with specifics related to the latest update (2008) on the Off-Highway Gasoline Use Model and the Public Use of Gasoline Model. The Off-Highway Gasoline Use Model is made up of five individual modules, one for each of the off-highway categories: agricultural, industrial and commercial, construction, aviation, and marine. This 2008 update of the off-highway models was the second major update (the first model update was conducted during 2002-2003) after they were originally developed in mid-1990. The agricultural model methodology, specifically, underwent a significant revision because of changes in data availability since 2003. Some revision to the model was necessary due to removal of certain data elements used in the original estimation method. The revised agricultural model also made use of some newly available information, published by the data source agency in recent years. The other model methodologies were not drastically changed, though many data elements were updated to improve the accuracy of these models. Note that components in the Public Use of Gasoline Model were not updated in 2008. A major challenge in updating estimation methods applied by the public-use model is that they would have to rely on significant new data collection efforts. In addition, due to resource limitation, several components of the models (both off-highway and public-us models) that utilized regression modeling approaches were not recalibrated under the 2008 study. An investigation of the Environmental Protection Agency's NONROAD2005 model was also carried out under the 2008 model update. Results generated from the NONROAD2005 model were analyzed, examined, and compared, to the extent that is possible on the overall totals, to the current FHWA estimates. Because NONROAD2005 model was designed for emission estimation purposes (i.e., not for measuring fuel consumption), it covers different equipment populations from those the FHWA models were based on. Thus, a direct comparison generally was not possible in most sectors. As a result, NONROAD2005 data were not used in the 2008 update of the FHWA off-highway models. The quality of fuel use estimates directly affect the data quality in many tables published in the Highway Statistics. Although updates have been made to the Off-Highway Gasoline Use Model and the Public Use Gasoline Model, some challenges remain due to aging model equations and discontinuation of data sources.

Hwang, Ho-Ling [ORNL; Davis, Stacy Cagle [ORNL

2009-12-01T23:59:59.000Z

126

Federal Memorandum of Understanding for Hydropower/Federal Inland...  

Open Energy Info (EERE)

of Energy Environmental Protection Agency Federal Energy Regulatory Commission Fish and Wildlife Service Forest Service National Oceanic and Atmospheric Administration...

127

EA-2001: Final Rule, 10 CFR Part 433, ‘Energy Efficiency Standards for New Federal Commercial and Multi-Family High- Rise Residential Buildings’ Baseline Standards Update  

Broader source: Energy.gov [DOE]

The EA examines the potential incremental environmental impacts of the PreliminaryFinal Rule on building habitability and the outdoor environment. To identify the potential environmental impacts that may result from implementing the PreliminaryFinal Rule, DOE compared the PreliminaryFinal Rule with the “no-action alternative” of using the minimum requirements of the previous version of the Federal standard – 10 CFR Part 433 (referred to as the “no-action alternative”).

128

Worker Safety and Health Program for DOE (Including the National Nuclear Security Administration) Federal and Contractor Employees  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This document was developed to assist the Department of Energy (DOE or the Department) Federal and contractor employees in effectively developing, managing, and implementing a worker safety and health program. Cancels DOE G 440.1-1A and DOE G 440.1-8. Adm Chg 1, dated 3-22-13.

2011-10-20T23:59:59.000Z

129

Worker Safety and Health Program for DOE (Including the National Nuclear Security Administration) Federal and Contractor Employees  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This document was developed to assist the Department of Energy (DOE or the Department) Federal and contractor employees in effectively developing, managing, and implementing a worker safety and health program. Cancels DOE G 440.1-1A and DOE G 440.1-8. Adm Chg 1, dated 3-22-13, cancels DOE G 440.1-1B.

2011-10-20T23:59:59.000Z

130

Bonneville Power Ampere Annex Z-995 Building  

High Performance Buildings Database

Vancouver, WA The Bonneville Power Administration (BPA), a federal agency headquartered in Portland, Oregon, provides about half of the electricity used in the Pacific Northwest and operates more than three-fourths of the region's high-voltage transmission. Because BPA markets power at cost from 31 federal dams, its rates are among the least expensive electricity in the country. The Ampere Annex project is a renovation of an exisiting 60-year-old standard warehouse building located within the Ross Complex.

131

Radiation control coatings installed on federal buildings at Tyndall Air Force Base. Volume 1: Pre-coating monitoring and fresh coating results  

SciTech Connect (OSTI)

The US Department of Energy`s (DOE`s) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the federal sector. One such effort, the New Technology Demonstration Program (NTDP), seeks to evaluate new energy-saving US technologies and secure their more timely adoption by the US government. Through a partnership with a federal site, the utility serving the site, a manufacturer of an energy-related technology, and other organizations associated with these interests, DOE can evaluate a new technology. The results of the program give federal agency decision makers more hands-on information with which to validate a decision to utilize a new technology in their facilities. The partnership of these interests is secured through a cooperative research and development agreement (CRADA), in this case between Lockheed Martin Energy Research Corporation, the manager of the Oak Ridge National Laboratory (ORNL), Oak Ridge, Tennessee, and ThermShield International, Ltd., the manufacturer of the technology. This is the first volume of a two-volume report that describes the effects of radiation control coatings installed on federal buildings at Tyndall Air Force Base (AFB) in Florida by ThermShield International. ORNL`s Buildings Technology Center (BTC) was assigned the responsibility for gathering, analyzing, and reporting on the data to describe the effects of the coatings. This volume describes the monitoring plan and its implementation, the results of pre-coating monitoring, the coating installation, results from fresh coatings compared to pre-coating results, and a plan to decommission the monitoring equipment. By including results from roofs at Tyndall AFB and from an outdoor test facility at the BTC, the data cover the range from poorly insulated to well-insulated roofs and two kinds of radiation control coatings on various roof membranes.

Petrie, T.W.; Childs, P.W.

1997-02-01T23:59:59.000Z

132

Final Rule, Federal Register, 72 FR 72565, 10 CFR Parts 433,...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Standards for New Federal Commercial and Multi-Family High-Rise Residential Buildings and New Federal Low-Rise Residential Buildings, which was published in the Federal...

133

Fossil Fuel-Generated Energy Consumption Reduction for New Federal...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Fossil Fuel-Generated Energy Consumption Reduction for New Federal Buildings and Major Renovations of Federal Buildings OIRA Comparison Document Fossil Fuel-Generated Energy...

134

Better Buildings Neighborhood Program Business Models Guide:...  

Broader source: Energy.gov (indexed) [DOE]

Guide: Utility Program Administrator Market Better Buildings Neighborhood Program Business Models Guide: Utility Program Administrator Market Utility program administrator market...

135

Building Technologies Program | Clean Energy | ORNL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Building Technologies Program SHARE Building Technologies Program The Building Technologies Program Office administratively facilitates the integration of ORNL research across...

136

ANALYSIS OF CHP POTENTIAL AT FEDERAL SITES  

SciTech Connect (OSTI)

This document was prepared at the request of the U.S. Department of Energy's (DOE's) Federal Energy Management Program (FEMP) under its Technical Guidance and Assistance and Project Financing Programs. The purpose was to provide an estimate of the national potential for combined heat and power (also known as CHP; cogeneration; or cooling, heating, and power) applications at federal facilities and the associated costs and benefits including energy and emission savings. The report provides a broad overview for the U.S. Department of Energy (DOE) and other agencies on when and where CHP systems are most likely to serve the government's best interest. FEMP's mission is to reduce the cost to and environmental impact of the federal government by advancing energy efficiency and water conservation, promoting the use of renewable energy, and improving utility management decisions at federal sites. FEMP programs are driven by its customers: federal agency sites. FEMP monitors energy efficiency and renewable energy technology developments and mounts ''technology-specific'' programs to make technologies that are in strong demand by agencies more accessible. FEMP's role is often one of helping the federal government ''lead by example'' through the use of advanced energy efficiency/renewable energy (EERE) technologies in its own buildings and facilities. CHP was highlighted in the Bush Administration's National Energy Policy Report as a commercially available technology offering extraordinary benefits in terms of energy efficiencies and emission reductions. FEMP's criteria for emphasizing a technology are that it must be commercially available; be proven but underutilized; have a strong constituency and momentum; offer large energy savings and other benefits of interest to federal sites and FEMP mission; be in demand; and carry sufficient federal market potential. As discussed in the report, CHP meets all of these criteria. Executive Order 13123 directs federal facilities to use CHP when life-cycle costs indicate energy reduction goals will be met. FEMP can assist facilities to conduct this analysis. The model developed for this report estimates the magnitude of CHP that could be implemented under various performance and economic assumptions associated with different applications. This model may be useful for other energy technologies. It can be adapted to estimate the market potential in federal buildings for any energy system based on the cost and performance parameters that a user desires to assess. The model already incorporates a standard set of parameters based on available data for federal buildings including total building space, building type, energy use intensity, fuel costs, and the performance of many prime movers commonly used in CHP applications. These and other variables can be adjusted to meet user needs or updated in the future as new data become available.

HADLEY, S.W.

2002-03-11T23:59:59.000Z

137

Federal Government Energy Management Conservation Programs Reports...  

Broader source: Energy.gov (indexed) [DOE]

Policy Act (NECPA, Pub. L. No. 95-619), as amended, and provide information on energy consumption in Federal buildings, operations, and vehicles. Compiled by the Federal...

138

COSTSAFR 3. 0---User's manual: (Conservation Optimization Standard for Savings in Federal Residences): In support of proposed modifications to interim energy conservation standards for new federal residential buildings  

SciTech Connect (OSTI)

This document describes how to use the computer program developed under the Federal Residential Standard Project funded by the Department of Energy. The computer program provides an analysis of specific housing projects at a given site, using alternative fuel types, and considering alternative housing types. Designed around the concept of minimizing overall costs through energy conservation design--including first cost and future utility costs--the computer program establishes a standard design to which proposed housing designs are compared. It then provides a point table, for each housing type, that can be used to determine whether a proposed design meets the standard and how a design could be modified to meet the standard. The computer program has been designed for IBM-PC or compatible computers and is recorded on a floppy disk. This manual describes how to use the program and how to read the information that appears on the screen during program operation. It describes the inputs required and the various options presented to the user. The appendices provide more detailed information related to the output produced by the program. This output consists of point tables presenting points for each energy conservation option, and a point total that must be met to comply with the standard. The technical support document and economic analysis are separate documents that provide more information about the specifics of the standard.

Not Available

1988-06-01T23:59:59.000Z

139

A Decision Support Tool for Building Leasing Strategies to Achieve the Executive Order Mandate  

E-Print Network [OSTI]

#12;Electricity Projections 10 Source: U.S. Energy Information Administration 2011 US Government Spent Buildings · 30% Lower Operating expense · Use less energy ­ 25% decrease in electricity consumptions ­ 11 for Federal Government Green Buildings Members: Alexandre Cheytanov Nathan Bales Paramjeet Khanna Chris Swift

140

Better Buildings Neighborhood Program Data Upgrade Projects ...  

Energy Savers [EERE]

of Gasoline - Dataset Federal Reporting Recipient Information Better Buildings Neighborhood Program Home Accomplishments History Better Buildings Partners Stories Interviews Videos...

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Demonstration Assessment of Light Emitting Diode (LED) Walkway Lighting at the Federal Aviation Administration William J. Hughes Technical Center, in Atlantic City, New Jersey  

SciTech Connect (OSTI)

This report documents the results of a collaborative project to demonstrate a solid state lighting (SSL) general illumination product in an outdoor area walkway application. In the project, six light-emitting diode (LED) luminaires were installed to replace six existing high pressure sodium (HPS) luminaires mounted on 14-foot poles on a set of exterior walkways and stairs at the Federal Aviation Administration (FAA) William J. Hughes Technical Center in Atlantic City, New Jersey, during December, 2007. The effort was a U.S. Department of Energy (DOE) SSL Technology Gateway Demonstration that involved a collaborative teaming agreement between DOE, FAA and Ruud Lighting (and their wholly owned division, Beta LED). Pre- and post-installation power and illumination measurements were taken and used in calculations of energy savings and related economic payback, while personnel impacted by the new lights were provided questionnaires to gauge their perceptions and feedback. The SSL product demonstrated energy savings of over 25% while maintaining illuminance levels and improving illuminance uniformity. PNNL's economic analysis yielded a variety of potential payback results depending on the assumptions used. In the best case, replacing HPS with the LED luminaire can yield a payback as low as 3 years. The new lamps were quite popular with the affected personnel, who gave the lighting an average score of 4.46 out of 5 for improvement.

Kinzey, Bruce R.; Myer, Michael

2008-03-18T23:59:59.000Z

142

Federal Participation in LEED in 2005 Christopher Payne  

E-Print Network [OSTI]

and in the use of USGBC's Leadership in Energy & Environmental Design (LEED) Green Building Rating System. CERTIFIED FEDERAL BUILDINGS As of September 2005, US federal agencies have certified 24 federal buildings. Papers at prior USGBC conferences have discussed federal buildings built before 2005. Table 1 lists

143

Interim Final Rule and Request for Comments, Federal Register...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

New Federal Commercial and Multi-Family High-Rise Residential Buildings and New Federal Low-Rise Residential Buildings, which was published in the Federal Register on December 4,...

144

Federal Participation in LEED Christopher Payne1  

E-Print Network [OSTI]

1 Federal Participation in LEED Christopher Payne1 Beverly Dyer2 1 Environmental Energy-mail: CTPayne@lbl.gov 2 Federal Energy Management Program, U. S. Department of Energy. Phone: +1 202 586 expectations for ongoing partnership. CERTIFIED FEDERAL BUILDINGS US federal agencies have certified 16 federal

145

History of federal transportation policy  

E-Print Network [OSTI]

History of federal transportation policy TTP 220 S. Handy 4/7/14 #12;Federal Transportation Policy · Rise of road building (1910s +) · Rise of mandated planning (1960s +) · Rise of transit funding (1960s for road building support from the start! · Cars seen as way to decentralize, to get people away from ills

Handy, Susan L.

146

Notice of Proposed Rulemaking, Federal Register, 75 FR 63404...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

15, 2010 Document details the notice of proposed rulemaking for Fossil Fuel-Generated Energy Consumption Reduction for New Federal Buildings and Major Renovations of Federal...

147

Notice of Availability, Federal Register, 75 FR 78231, December...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Federal Register, 75 FR 78231, December 15, 2010 Notice of availability for the Management of Energy and Water Efficiency in Federal Buildings, which was published in the...

148

Use of Metering for Facility and Whole Building Energy Analysis by the U.S. Depratment of Energy Federal Energy Management Program  

E-Print Network [OSTI]

This paper details how the U.S. Department of Energy, Federal Energy Management Program (FEMP) is applying metering technology to conduct empirically based analyses o f energy use by federal agencies. Continuing developments in sensors, data...

Devine, K. D.; Mazzucchi, R. P.

1989-01-01T23:59:59.000Z

149

Title 33 CFR 115 Bridge Locations and Clearances: Administrative...  

Open Energy Info (EERE)

Bridge Locations and Clearances: Administrative Procedures Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- Federal RegulationFederal Regulation:...

150

Federal Government Congressional Budget Office, Budget Analysis Division Washington, DC  

E-Print Network [OSTI]

Administration, Center for Drug Evaluation and Research Washington, DC Federal Energy Regulatory CommissionFederal Government Congressional Budget Office, Budget Analysis Division Washington, DC Department Environmental Protection Agency, Office of Transportation & Air Quality Ann Arbor, MI Federal Drug

Shyy, Wei

151

Notice of Proposed Rulemaking, Federal Register, 75 FR 29933...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

75fr29933.pdf More Documents & Publications EA-1991: Notice of Proposed Rulemaking Green Building Certification Systems Requirement for New Federal Buildings and Major...

152

Energy Goals and Standards for Federal Government  

Broader source: Energy.gov [DOE]

The federal Energy Policy Act of 2005 (EPAct 2005) established several goals and standards to reduce energy use in existing and new federal buildings. Executive Order 13423, signed in January 2007...

153

Memorandum of American High-Performance Buildings Coalition DOE...  

Energy Savers [EERE]

Leadership in High Performance and Sustainable Buildings Memorandum of Understanding Green Building Certification Systems Requirement for New Federal Buildings and Major...

154

Rule to Support Increased Energy Measurement and Efficient Building...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

for new and retrofitted federal buildings that are certified by private sector green building certification systems. The use of green building rating systems advances...

155

Federal Buildings Supplemental Survey 1993  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia,(Million Barrels) Crude Oil Reserves in Nonproducing Reservoirs U.S.WyomingExpansion and Change on the U.S.Explanatory3

156

Federal Buildings Supplemental Survey -- Overview  

Gasoline and Diesel Fuel Update (EIA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines About U.S.30Natural Gas Glossary529 633 6221,2372003of Energy2009 2010 2011S5.

157

Evaluating the energy performance of the first generation of LEED-certified commercial buildings  

E-Print Network [OSTI]

The Federal Commitment to Green Building: Experiences andEvaluation Report. Cascadia Green Building Council.U.S. Green Building Council (USGBC). 2003. "Green Building

Diamond, Rick

2011-01-01T23:59:59.000Z

158

Management and Administration of Radiation Protection Programs Guide for Use with Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Guide discusses acceptable methods for ensuring that radiological activities will be managed and administered in accordance with a documented radiation protection program (RPP) that complies with U.S. Department of Energy (DOE) requirements specified in Title 10 of the Code of Federal Regulations (CFR), Part 835, Occupational Radiation Protection (DOE 1998a), hereinafter referred to as 10 CFR 835. Canceled by DOE G 441.1-1A.

1999-03-17T23:59:59.000Z

159

Federal Utility Partnership Working Group Participants | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

in the Federal Utility Partnership Working Group or engaged in a utility energy service contract project. General Services Administration National Aeronautics and Space...

160

Room 108, Henry Hicks Academic Administration Building 6299 South Street P.O. Box 15000 Halifax, NS B3H 4R2 Canada Tel: 902.494. 2586 Fax: 902.494.1658 www.dal.ca  

E-Print Network [OSTI]

Room 108, Henry Hicks Academic Administration Building · 6299 South Street · P.O. Box 15000's Science College of Sustainability 1year postreview progress updates 201314 201415 201516 Engineering Science Management King's Medicine College of Sustainability #12;Room 108, Henry

Brownstone, Rob

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

6999Federal Register / Vol. 71, No. 28 / Friday, February 10, 2006 / Proposed Rules vi. Federal Rules That May Duplicate,  

E-Print Network [OSTI]

March 9, 2006. ADDRESSES: The hearing will be in room 154 of the U.S. Federal Office Building, 222 W. 7 for submitting comments. · Mail: P. O Box 21668, Juneau, AK 99802 · Hand delivery to the Federal Building : 709 W6999Federal Register / Vol. 71, No. 28 / Friday, February 10, 2006 / Proposed Rules vi. Federal

162

Administration and Service Buildings Instructional Buildings  

E-Print Network [OSTI]

. Swimming Pool Mathematics Research Center Bldg. Dept. of Psychology (South Hall. B Incubation Center Bldg. C Bike Pound Si-Yuan Hall Halcyon House Bldg. No. 1 Agricultural Exhibition Hall New Moon Pavilion NTU Visitor Center Lesyue Bldg. Old Main Library College of Liberal Arts

Hung, Shih-Hao

163

Administration and Service Buildings Instructional Buildings  

E-Print Network [OSTI]

-Yuan Hall Halcyon House Bldg. No. 1 Agricultural Exhibition Hall New Moon Pavilion NTU Visitor Center Lesyue - Mathematics Bldg. Shih-Liang Hall Computer and Information Networking Center Dept. of Mathematics Dept. of Chemistry Freshman Classroom Bldg. 9th Women's Dorm 8th Women's Dorm Dept. of Psychology (North Hall

Hung, Shih-Hao

164

Buildings and Areas 1001 Broadway Building D1 BDWY  

E-Print Network [OSTI]

Design (LEED) Green Building Rating System is a nationally accepted benchmark for the designBuildings and Areas 1001 Broadway Building D1 BDWY 1313 East Columbia Building B3 CLMB Administration Building D1 ADMN Admissions & C2 ADAL Alumni Building Archbishop Murphy A1 ATMA Apartments Arrupe

Carter, John

165

Building Energy Efficient Schools  

E-Print Network [OSTI]

for extremely inefficient buildings. To accomplish this, the school administrator must be an active participant in the design process. Energy efficient school design is a team effort involving the architect, engineer, and school administrator. This paper...

McClure, J. D.; Estes, J. M.

1985-01-01T23:59:59.000Z

166

American Recovery and Reinvestment Act Federal Energy Management Program Technical Assistance Project 184 U.S. Customs and Border Protection Administrative and Laboratory Building, Springfield, Virginia  

SciTech Connect (OSTI)

This report documents the findings of an on-site energy audit of the U.S. Customs and Border Protection Laboratory in Springfield, Virginia.

Arends, J.; Sandusky, William F.

2010-09-30T23:59:59.000Z

167

SIVE Workshop '95 Building Map  

E-Print Network [OSTI]

SIVE Workshop '95 Building Map Workshop . Room W401 in Pappajohn Business Administration Building RIVERSIDE DRIVE (HIGHWAYS 1 & 6) Highways 1 & 6 (from Coralville) Riverside Drive RIVER IOWA ART BUILDING 1234567890 1234567890 1234567890 1234567890 Pappajohn Business Administration Building IMU RAMP DUBUQUE ST

Cremer, James

168

Federal Biomass Activities  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

and Budget Federal Biomass Activities Federal Biomass Activities Biopower Biopower Biofuels Biofuels Bioproducts Bioproducts Federal Biomass Activities Federal Biomass...

169

Benefits of Sustainable Building Design  

Broader source: Energy.gov [DOE]

The application of sustainable building design not only helps Federal facilities meet laws and regulations, it also provides them with many other benefits. These benefits include:

170

RECENT TRENDS IN FEDERAL LAB TECHNOLOGY  

E-Print Network [OSTI]

Budget Resources for Federal Lab R&D Spending, Ranked by Budget Level Table 2.2 Distribution of Active#12;RECENT TRENDS IN FEDERAL LAB TECHNOLOGY TRANSFER: FY 1999­2000 BIENNIAL REPORT Report Administration U.S. Department of Commerce May 2002 #12;RECENT TRENDS IN FEDERAL LAB TECHNOLOGY TRANSFER: FY

Perkins, Richard A.

171

Projected Benefits of Federal Energy Efficiency and  

E-Print Network [OSTI]

Projected Benefits of Federal Energy Efficiency and Renewable Energy Programs FY 2008 Budget is clean, abundant, reliable, and affordable #12;Projected Benefits of Federal Energy Efficiency Coordinator: Michael Leifman o Biomass: Zia Haq, Tien Nguyen o Buildings: Jerry Dion, David Boomsma o Federal

172

51.99.99.M0.01 Procedure for Capitalizing Improvements on Buildings Page 1 of 3 STANDARD ADMINISTRATIVE PROCEDURE  

E-Print Network [OSTI]

(heating/cooling, electric, plumbing) interior or exterior upgrades, additions, and space conversions. 2 - Replacement of the heating/cooling system as part of a building renovation that increases the useful life and. Example - rehabilitation of a building that may include, but is not limited to, upgraded building systems

173

A synthesis of ethnohistorical materials concerning the administration of Federal Indian policy among the Yakima, Umatilla, and Nez Perce Indian people: Working draft  

SciTech Connect (OSTI)

For the purposes of the Nuclear Waste Policy Act, the Confederated Tribes and Bands of the Yakima Indian Nation, the Confederated Tribes of the Umatilla Indian Reservation, and the Nez Perce Tribe have been accorded the status of ''Affected Indian Tribe'' and have become party to the proceedings to determine a suitable location for the nation's first commercial waste repository. Each of the Tribes has expressed concerns about the suitability of the Hanford Site in eastern Washington. These concerns, in general, address the proposed repository's effects on traditional spiritual beliefs and cultural practices, on tribal sovereignty and the Tribes' right to self-government, on the natural resources under tribal management jurisdiction, and on the health and socioeconomic characteristics of the Tribes' reservation communities. The Yakima, Umatilla, and Nez Perce have distinctive cultural traditions that may be adversely affected by activities related to the Basalt Waste Isolation Project (BWIP). Further, the Tribes enjoy a unique relationship with the federal government. Because of their distinctive cultures and governmental status, particular attention will be paid to expressed interests of the Tribes, and to ways in which these interests may be affected by the repository program. Monitoring is needed to describe current conditions among the Affected Tribes' populations, to describe BWIP site characterization activities affecting the Tribes, and to measure any changes in these conditions that may occur as a direct result of site characterization. This paper reports our first efforts at gathering historical information. It summarizes materials contained in two sources: the reports of field agents to the Commissioner of Indian Affairs (1854-1936), and the dockets of the Indian Claims Commission. 24 refs., 3 figs.

Liebow, E.B.; Younger, C.A.; Broyles, J.A.

1987-11-01T23:59:59.000Z

174

California Federal Facilities: Rate-Responsive Buidling Operating for Deeper Cost and Energy Savings  

Broader source: Energy.gov [DOE]

Fact sheet from the Federal Energy Management Program (FEMP) describes rate-responsive building operations for cost and energy savings in California federal facilities.

175

High-Performance Sustainable Building Design for New Construction and Major Renovations  

Broader source: Energy.gov [DOE]

New construction and major renovations to existing buildings offer Federal agencies opportunities to create sustainable high-performance buildings. High-performance buildings can incorporate energy...

176

U.S. Federal Government- Green Power Purchasing Goal  

Broader source: Energy.gov [DOE]

The federal Energy Policy Act of 2005 (EPAct 2005) extended and expanded several previous goals and standards to reduce energy use in existing and new federal buildings. Section 203 of EPAct 2005...

177

Building International Emergency Management Systems | National...  

National Nuclear Security Administration (NNSA)

Building International Emergency Management Systems | National Nuclear Security Administration Facebook Twitter Youtube Flickr RSS People Mission Managing the Stockpile Preventing...

178

GAO-11-520T Federal Real Property: Progress Made on Planning...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Before the Subcommittee on Economic Development, Public Buildings and Emergency Management, Committee on Transportation and Infrastructure, House of Representatives FEDERAL...

179

Obama Administration Announces Johnson Controls, Macy's and Sprint...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Johnson Controls, Macy's and Sprint Join the Better Buildings Challenge Obama Administration Announces Johnson Controls, Macy's and Sprint Join the Better Buildings Challenge...

180

NNSA Awards Contract for Largest Federal Wind Farm to Siemens...  

National Nuclear Security Administration (NNSA)

Contract for Largest Federal Wind Farm to Siemens Government Technologies, Inc. | National Nuclear Security Administration Facebook Twitter Youtube Flickr RSS People Mission...

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Y-12 Site Office Recognized For Contributions To Combined Federal...  

National Nuclear Security Administration (NNSA)

To ... Y-12 Site Office Recognized For Contributions To Combined Federal Campaign OAK RIDGE, Tenn. -- Employees of the National Nuclear Security Administration's Y-12 Site...

182

Passive solar buildings  

SciTech Connect (OSTI)

Developments in passive solar buildings that took place from the early 1970`s through 1989 are described. Much of the work covered was federally sponsored during the period 1975 through 1986. About half the volume is devoted to quantitative methods for modeling, simulation, and design analysis of passive buildings; the other half summarizes the quantitative results of testing and monitoring of models and buildings. The following are covered: building solar gain modeling, simulation analysis, simplified methods, materials and components, analytical results for specific systems, test modules, building integration, performance monitoring and results, and design tools. (MHR)

Balcomb, J.D. [ed.] [Solar Energy Research Inst., Golden, CO (United States)

1992-10-01T23:59:59.000Z

183

Passive solar buildings  

SciTech Connect (OSTI)

Developments in passive solar buildings that took place from the early 1970's through 1989 are described. Much of the work covered was federally sponsored during the period 1975 through 1986. About half the volume is devoted to quantitative methods for modeling, simulation, and design analysis of passive buildings; the other half summarizes the quantitative results of testing and monitoring of models and buildings. The following are covered: building solar gain modeling, simulation analysis, simplified methods, materials and components, analytical results for specific systems, test modules, building integration, performance monitoring and results, and design tools. (MHR)

Balcomb, J.D. (ed.) (Solar Energy Research Inst., Golden, CO (United States))

1992-01-01T23:59:59.000Z

184

Federal Housing Administration's Energy Efficient Mortgage Program...  

Broader source: Energy.gov (indexed) [DOE]

Describes the U.S. Department of Housing and Urban Development Energy Efficient Mortgage Program which helps homebuyers or homeowners save money on utility bills by enabling them...

185

Federal Employment | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment ofDepartment ofofOxford SiteToledoSampling at the GrandSr:s I1Us |Contact

186

Federal Housing Administration's Energy Efficient Mortgage Program |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPCofConstructionofFYOxideof1 DOEFederal

187

federal budget | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartmentNationalRestart of the Review of theOFFICE OF CIVILAMENDMENT20/%2A6/%2A6/%2A

188

The Federal Energy Administration | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomenthe House Committee on EnergyEnergy SecretarySeries |Energy John7The

189

THE FEDERAL ENERGY ADMINISTRATION By Roger Anders  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up from the GridwiseSiteDepartmentChallengeCompliance7/109 INSTITUTIONALFEDERAL

190

Federal Aviation Administration | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision has beenFfe2fb55-352f-473b-a2dd-50ae8b27f0a6 NoSan Leandro,LawFEMAProject JumpTechnologiesAviation

191

Strategies for Decreasing Petroleum Consumption in the Federal Fleet (Presentation)  

SciTech Connect (OSTI)

Presentation offers strategies federal agency fleets can use to reduce petroleum consumption and build or gain access to alternative fuel infrastructure.

Putsche, V.

2006-06-01T23:59:59.000Z

192

Procuring Solar Energy: A Guide for Federal Facility Decision...  

Office of Environmental Management (EM)

site. It is specifically targeted to managers of federal buildings and sites, contracting officers, energy and sustainability officers, and regional procurement managers....

193

Federal Finance Facilities Available for Energy Efficiency Upgrades...  

Broader source: Energy.gov (indexed) [DOE]

Interagency Initiatives o Working with our federal and state partners to benefit rural energy consumers * Internal Capacity Building o Staff engagement training o Coordination...

194

Public Meeting Transcript: Sustainable Design Standards for Federal...  

Office of Environmental Management (EM)

transcript is from the public meeting to discuss sustainable design standards for Federal buildings held on July 28, 2010. noprmeeting072810.pdf More Documents & Publications...

195

EISA Section 432: Federal Facility Management and Benchmarking...  

Broader source: Energy.gov (indexed) [DOE]

for how these activities fit into the comprehensive approach to facility energy and water management, as outlined by the statute. Federal Building Energy Use Benchmarking...

196

Energy Efficient State Building Initiative  

Broader source: Energy.gov [DOE]

In June 2008, Governor Mitch Daniels issued an executive order establishing an energy efficient state buildings initiative. The order requires the Indiana Department of Administration (DOA) to...

197

San Francisco Building Code Amendments to the  

E-Print Network [OSTI]

Green Building Standards Code 2010 California Residential Code Operative date: January 1, 2011 #12;2 #121 2010 San Francisco Building Code Amendments to the 2010 California Building Code 2010 California;3 CHAPTER 1 SCOPE AND ADMINISTRATION DIVISION I CALIFORNIA ADMINISTRATION No San Francisco Building Code

198

American Recovery and Reinvestment Act ( ARRA) FEMP Technical Assistance, U.S. General Services Administration - Project 194 U.S. Custom Cargo Inspection Facility, Detroit, MI  

SciTech Connect (OSTI)

This report documents the findings of an on-site audit of the U.S. Customs Cargo Inspection Facility (CIF) in Detroit, Michigan. The federal landlord for this building is the General Services Administration (GSA). The focus of the audit was to identify various no-cost or low-cost energy-efficiency opportunities that, once implemented, would reduce electrical and gas consumption and increase the operational efficiency of the building. This audit also provided an opportunity to identify potential capital cost projects that should be considered in the future to acquire additional energy (electric and gas) and water savings to further increase the operational efficiency of the building.

Arends, J.; Sandusky, William F.

2010-05-31T23:59:59.000Z

199

Best Practices in Existing Building Commissioning  

Broader source: Energy.gov [DOE]

Presentation covers the Best Practices in Existing Building Commissioning and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Rapid City, South Dakota.

200

Existing Building Commissioning (EBCx) Project Considerations  

Broader source: Energy.gov [DOE]

Presentation covers the existing building commissioning (EBCx) project considerations, and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Rapid City, South Dakota.

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Rudy Garibay, Senior Graphic Designer, The Arts Administrative Group. 116D Music Building e: rrgaribay@ucdavis.edu o: 530.754.2258 c: 530.383.0617  

E-Print Network [OSTI]

. Services are not for personal use and do not include class materials. All work remains property Postcards Photo editing Programs Project management Posters Web graphics Web design Web updating typi as a whole, departments, programs, and faculty for administrative and academic purposes and department

Hernes, Peter J.

202

E-Print Network 3.0 - administration compliance program Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

finance, compliance issues related to federally funded programs, operational... efficiency, strategic planning, financial modeling, and other administrative,...

203

Intercity Passenger Rail Federal Funding presented by  

E-Print Network [OSTI]

Intercity Passenger Rail ­ Federal Funding Process presented by: Minnesota Department, equipment and connections ·! Long term: build efficient HSR network ­! Connecting major population centers ·! Lead state on Milwaukee to Twin Cities segment ·! 2008 state bonding to match federal funds

Minnesota, University of

204

University Buildings Landmark Buildings  

E-Print Network [OSTI]

KEY University Buildings Landmark Buildings The Lanyon Building Roads Footpath Cafe Grass Queen's University Belfast Campus Map The Lanyon Building The Students' Union The David Keir Building School Offices and Sonic Arts Q Nursing and Midwifery R Pharmacy S Planning, Architecture and Civil Engineering T Politics

Paxton, Anthony T.

205

University Buildings Landmark Buildings  

E-Print Network [OSTI]

KEY University Buildings Landmark Buildings The Lanyon Building Roads Footpath Cafe University Accommodation Queen's University Belfast Campus Map The Lanyon Building The Students' Union The David Keir Building School Offices A Biological Sciences B Chemistry and Chemical Engineering C Education D

Müller, Jens-Dominik

206

Energy Information Administration - Commercial Energy Consumption...  

Gasoline and Diesel Fuel Update (EIA)

to totals. Source: Energy Information Administration, Office of Energy Markets and End Use, Forms EIA-871A, C, and E of the 2003 Commercial Buildings Energy Consumption Survey....

207

143Business Administration BUSINESS ADMINISTRATION  

E-Print Network [OSTI]

143Business Administration BUSINESS ADMINISTRATION (BUS) PROFESSORS CLINE, DEAN, KESTER VISITING ASSOCIATE PROFESSOR GIBBS ASSISTANT PROFESSOR REITER MAJOR A major in business administration leading at least 24 credits in business administration and 26 credits not in business administration, as follows: 1

Dresden, Gregory

208

Energy-Efficient Commercial Buildings Tax Deduction  

Broader source: Energy.gov [DOE]

The federal Energy Policy Act of 2005 established a tax deduction for energy-efficient commercial buildings applicable to qualifying systems and buildings placed in service from January 1, 2006,...

209

U.S. Energy Information Administration | Annual Energy Outlook...  

Gasoline and Diesel Fuel Update (EIA)

Federal Highway Administration, Highway Statistics 2010 (Washington, DC, February 2012); Oak Ridge National Laboratory, Transportation Energy Data Book: Edition 31 (Oak Ridge, TN,...

210

Obama Administration and Great Lakes States Announce Agreement...  

Office of Environmental Management (EM)

on Historic Preservation U.S. Coast Guard U.S. Environmental Protection Agency U.S. Fish and Wildlife Service Federal Aviation Administration National Oceanic and Atmospheric...

211

Building 32 35 Building 36  

E-Print Network [OSTI]

Building 10 Building 13 Building 7 LinHall Drive Lot R10 Lot R12 Lot 207 Lot 209 LotR9 Lot 205 Lot 203 LotBuilding30 Richland Avenue 39 44 Building 32 35 Building 36 34 Building 18 Building 19 11 12 45 29 15 Building 5 8 9 17 Building 16 6 Building 31 Building 2 Ridges Auditorium Building 24 Building 4

Botte, Gerardine G.

212

What is the Federal Demonstration Project  

SciTech Connect (OSTI)

The Federal Demonstration Project is a cooperative effort between a number of universities, a private research institute, and several federal agencies to increase research productivity by eliminating unnecessary administrative procedures and by streamlining and standardizing needed controls. The Project aims to locate responsibility for decision-making as close as possible to principal investigators while maintaining necessary institutional and agency oversight to ensure accountability. By freeing researchers from some of their paperwork burden, more efficient research administration systems will enable investigators to spend more of their time doing science and engineering. The Federal Demonstration Project is an outgrowth of an earlier activity sponsored by five major federal R D agencies at the Florida State University System and the University of Miami. In Florida, the focus was on standardizing and streamlining procedures for administering research grants after the grants had been awarded to the universities. (See Attachment 1 for descriptions of the demonstrations carried out under the Florida Demonstration Project). In May 1988, the most successful of the demonstrated procedures were approved by the US Office of Management and Budget for use in grants awarded by any federal agency to any research organization. The new procedures give agencies authority to waive requirements that grantees obtain federal approval prior to taking a number of administrative actions with respect to grant management. The FDP institutions together with the participating federal agencies are designing and demonstrating innovative research administration procedures and are assessing the impact of those new procedures.

Not Available

1990-01-01T23:59:59.000Z

213

Federal CHP Potential 1 Does your facility have CHP  

E-Print Network [OSTI]

. The Federal building types with greatest CHP potential are hospitals, industrial, and R&D facilities. Figure 1) systems provide thermal energy for buildings or processes while at the same time generating electricity extraordinary efficiency and environmental benefits. The U.S. Department of Energy's (DOE's) Federal Energy

Oak Ridge National Laboratory

214

SOUTHEASTERN FEDERAL POWER ALLIANCE Martin Luther King, Jr. Federal Building  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAXBalancedDepartmentRestrictions onSBBiodiesel |Energy October 9, 2013Martin

215

SOUTHEASTERN FEDERAL POWER ALLIANCE Sam Nunn Federal Building  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAXBalancedDepartmentRestrictions onSBBiodiesel |Energy October 9, 2013MartinSam

216

Recommendations and Justifications for Modifications To Downgrade Use Restrictions Established under the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office Federal Facility Agreement and Consent Order, Revision 1  

SciTech Connect (OSTI)

This document is part of an effort to reevaluate 37 FFACO and Administrative URs against the current Soils Risk-Based Corrective Action Evaluation Process. After reviewing 37 existing FFACO and Administrative URs, 11 URs addressed in this document have sufficient information to determine that these current URs may be downgraded to Administrative URs based on the RBCA criteria. This document presents recommendations on modifications to existing URs that will be consistent with the RBCA criteria.

Birney, Cathleen; Krauss, Mark J

2013-10-01T23:59:59.000Z

217

Sustainable Building Basics  

Broader source: Energy.gov [DOE]

Sustainable building design and operation strategies demonstrate a commitment to energy efficiency, and environmental stewardship. These approaches result in an optimal balance of energy, cost, environmental, and societal benefits, while still meeting the mission of a Federal agency and the function of the facility or infrastructure. For buildings and facilities, responsible resource management and the assessment of operational impacts encompass the principles of sustainability. Sustainable development aims to meet the needs of the present without compromising future needs.

218

Social Security Administration Child Care Center  

High Performance Buildings Database

Woodlawn, MD The Social Security Administration Child Care Center is located in suburban Baltimore, Maryland. Three main building components are identified by function and by form. The "head" includes the entry, child and building services, and administration space. The project also has two distinct "arms": one containing classrooms for infants and young toddlers and the other containing classrooms for older toddlers, preschoolers, and kindergarteners.

219

Funding Solar Projects at Federal Agencies: Mechanisms and Selection Criteria (Brochure)  

SciTech Connect (OSTI)

Implementing solar energy projects at federal facilities is a process. The project planning phase of the process includes determining goals, building a team, determining site feasibility and selecting the appropriate project funding tool. This fact sheet gives practical guidance to assist decision-makers with understanding and selecting the funding tool that would best address their site goals. Because project funding tools are complex, federal agencies should seek project assistance before making final decisions. High capital requirements combined with limits on federal agency energy contracts create challenges for funding solar projects. Solar developers typically require long-term contracts (15-20) years to spread out the initial investment and to enable payments similar to conventional utility bill payments. In the private sector, 20-year contracts have been developed, vetted, and accepted, but the General Services Administration (GSA) contract authority (federal acquisition regulation [FAR] part 41) typically limits contract terms to 10 years. Payments on shorter-term contracts make solar economically unattractive compared with conventional generation. However, in several instances, the federal sector has utilized innovative funding tools that allow long-term contracts or has created a project package that is economically attractive within a shorter contract term.

Not Available

2012-03-01T23:59:59.000Z

220

Plug-Load Control and Behavioral Change Research in GSA Office Buildings  

SciTech Connect (OSTI)

The U.S. General Services Administration (GSA) owns and leases over 354 million square feet (ft2) of space in over 9,600 buildings [1]. GSA is a leader among federal agencies in aggressively pursuing energy efficiency (EE) opportunities for its facilities and installing renewable energy (RE) systems to provide heating, cooling, and power to these facilities. According to several energy assessments of GSA's buildings conducted by the National Renewable Energy Laboratory (NREL), plug-loads account for approximately 21% of the total electricity consumed within a standard GSA Region 3 office building. This study aims to provide insight on how to effectively manage plug-load energy consumption and attain higher energy and cost savings for plug-loads. As GSA improves the efficiency of its building stock, plug-loads will become an even greater portion of its energy footprint.

Metzger, I.; Cutler, D.; Sheppy, M.

2012-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

FOCUSPublic Administration  

E-Print Network [OSTI]

international stage in our efforts to develop the professional public service infrastructure. Our Romanian administration and the Romanian Review of Local Public Administration, utilizes best practices from the public

Van Stryland, Eric

222

Research Administration & Finance Tip of the Week  

E-Print Network [OSTI]

Research Administration & Finance Tip of the Week Catalogue of Federal Domestic Assistance (CFDA) Overview What is a CFDA number? The Catalog of Federal Domestic Assistance (CFDA) is a government. The complete CFDA number is a five digit number, XX.XXX, where the first two digits represent the Funding

Salama, Khaled

223

Federal Register  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAX POLICIES ANDIndustrialEnergy FederalFLASH 2004-12 April 5, 2004

224

Federal Register  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAX POLICIES ANDIndustrialEnergy FederalFLASH 2004-12 April 5, 200465541 Vol. 79,

225

Federal Register  

National Nuclear Security Administration (NNSA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartmentNationalRestart of the Review of theOFFICEACME |Supplement5869Google10 Federal

226

Federal Register  

National Nuclear Security Administration (NNSA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartmentNationalRestart of the Review of theOFFICEACME |Supplement5869Google10 Federal2985

227

Federal Register  

National Nuclear Security Administration (NNSA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartmentNationalRestart of the Review of theOFFICEACME |Supplement5869Google102479 Federal

228

Federal Register  

National Nuclear Security Administration (NNSA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartmentNationalRestart of the Review of theOFFICEACME |Supplement5869Google102479 Federal989

229

Federal Register  

National Nuclear Security Administration (NNSA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartmentNationalRestart of the Review of theOFFICEACME |Supplement5869Google10247954 Federal

230

Federated search  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-Series toESnet4:Epitaxial ThinFORFALL NEWS ROCKYGas FedEx®|default SignFederated

231

Commercial Buildings Characteristics, 1992  

SciTech Connect (OSTI)

Commercial Buildings Characteristics 1992 presents statistics about the number, type, and size of commercial buildings in the United States as well as their energy-related characteristics. These data are collected in the Commercial Buildings Energy Consumption Survey (CBECS), a national survey of buildings in the commercial sector. The 1992 CBECS is the fifth in a series conducted since 1979 by the Energy Information Administration. Approximately 6,600 commercial buildings were surveyed, representing the characteristics and energy consumption of 4.8 million commercial buildings and 67.9 billion square feet of commercial floorspace nationwide. Overall, the amount of commercial floorspace in the United States increased an average of 2.4 percent annually between 1989 and 1992, while the number of commercial buildings increased an average of 2.0 percent annually.

Not Available

1994-04-29T23:59:59.000Z

232

Federal Building Benchmarking Guidance - August 2014 Update  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAX POLICIES ANDIndustrial HygieneEnergyLead-acidPrimusContinued72Agency NEPA

233

Federal Buildings Supplemental Survey - Index Page  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia,(Million Barrels) Crude Oil Reserves in Nonproducing Reservoirs U.S.WyomingExpansion and Change on the U.S.Explanatory3

234

Federal Buildings Supplemental Survey -- Publication and Tables  

Gasoline and Diesel Fuel Update (EIA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines About U.S.30Natural Gas Glossary529 633 6221,2372003of Energy2009 2010 2011S5.Overview

235

Better Buildings Federal Award | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energyon ArmedWaste andAccess to OUOBartlesvillePersistent, andBerkeley Lab:Better

236

Bonneville Power Administration's Purchasing of Energy Savings  

E-Print Network [OSTI]

BONNEVILLE POWER ADMINISTRATION'S PURCHASE OF ENERGY SAVINGS Harold (Skip) Schick Leslie E. McMillan Bonneville Power Administration Port1and, Oregon INTRODUCTION The Bonneville Power Administration (BPA) is conducting a commercial... buildings retrofit program in the Pacific Northwest by making pay ments to a sponsor, such as an energy serv ice company or architectural and engineering firm, for energy savings which actually occur in a commercial building. This effort is one...

Schick, H.

237

Recommendations and Justifications To Remove Use Restrictions Established under the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office Federal Facility Agreement and Consent Order, Revision 0  

SciTech Connect (OSTI)

This document is part of an effort to reevaluate 37 FFACO and Administrative URs against the current Soils Risk-Based Corrective Action Evaluation Process. After reviewing 37 existing FFACO and Administrative URs, 3 URs addressed in this document have sufficient information to determine that these current URs may be removed, based on the RBCA criteria. This document presents recommendations on modifications to existing URs that will be consistent with the RBCA criteria.

Birney, Cathleen; Krauss, Mark J

2013-09-01T23:59:59.000Z

238

National Aeronautics and Space Administration OFFICE OF INSPECTOR GENERAL  

E-Print Network [OSTI]

Federal Acquisition Regulation FY Fiscal Year GAO Government Accountability Office GSA General Services-010 OVERVIEW NASA'S STRATEGIC SOURCING PROGRAM The Issue The Federal Government spends more than $500 billion Administration (GSA), historically, Federal agencies have acquired these products and services in a highly

Waliser, Duane E.

239

Green Building Certification Systems Requirement for New Federal Buildings  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Subject: GuidanceNotGrand Coulee-CrestonAmerican RecoveryBeer:and

240

Green Building Certification Systems Requirement for New Federal Buildings  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Subject: GuidanceNotGrand Coulee-CrestonAmerican

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

E.O.13514 Federal Leadership in Environmental, Energy, and  

E-Print Network [OSTI]

E.O.13514 Federal Leadership in Environmental, Energy, and Economic Performance Electricity Price Projections Natural Gas Price Projections Current Building · Aging building · Higher energy cost · Rising maintenance cost Green Building · More energy efficient · Saves money over life cycle · Improves employee job

242

Funding and Federal Staffing Requirements Funding Summary (Energy Supply)  

E-Print Network [OSTI]

Funding and Federal Staffing Requirements Funding Summary (Energy Supply) (dollars in thousands) FY Buildings Zero Energy Building Design . . . . . 1,367 8,000 4,000 -4,000 -50.0% Total, Zero-Energy Buildings-Temperature Superconducting R&D . . . . . . . . . . . . . . . . . . . . . . 31,991 47,838 47,838 0 0.0% Energy Supply Energy

243

NREL Buildings Research Video  

ScienceCinema (OSTI)

Through research, the National Renewable Energy Laboratory (NREL) has developed many strategies and design techniques to ensure both commercial and residential buildings use as little energy as possible and also work well with the surroundings. Here you will find a video that introduces the work of NREL Buildings Research, highlights some of the facilities on the NREL campus, and demonstrates these efficient building strategies. Watch this video to see design highlights of the Science and Technology Facility on the NREL campus?the first Federal building to be LEED® Platinum certified. Additionally, the video demonstrates the energy-saving features of NRELs Thermal Test Facility. For a text version of this video visit http://www.nrel.gov/buildings/about_research_text_version.html

None

2013-05-29T23:59:59.000Z

244

Program Administration  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This volume describes program administration that establishes and maintains effective organizational management and control of the emergency management program. Canceled by DOE G 151.1-3.

1997-08-21T23:59:59.000Z

245

ITL BULLETIN FOR AUGUST 2010 ASSESSING THE EFFECTIVENESS OF SECURITY CONTROLS IN FEDERAL  

E-Print Network [OSTI]

discusses the process for assessing the security controls in organizational information systems that are implemented in federal information systems. The selection and assessment of appropriate security controls Controls in Federal Information Systems and Organizations: Building Effective Security Assessment Plans

246

Annual report to Congress on Federal Government Energy Management and Conservation Programs, Fiscal Year 1997  

SciTech Connect (OSTI)

In fulfillment of statutory requirements, this report provides information on energy consumption in Federal buildings and operations and also documents activities conducted by Federal agencies in fulfilling those requirements during Fiscal Year 1997.

none,

1999-08-13T23:59:59.000Z

247

Annual report to Congress on Federal Government Energy Management and Conservation Programs, Fiscal Year 1998  

SciTech Connect (OSTI)

In fulfillment of statutory requirements, this report provides information on energy consumption in Federal buildings and operations and also documents activities conducted by Federal agencies in fulfilling those requirements during Fiscal Year 1998.

none,

2000-03-20T23:59:59.000Z

248

A Look at Office Buildings - Index  

Gasoline and Diesel Fuel Update (EIA)

professional offices, and administrative offices. For example, an office may be a computer center, bank, consultant's office, law office, or medical office. An office building...

249

FEDERAL INFORMATION PROCESSING STANDARD  

E-Print Network [OSTI]

March 2004 FEDERAL INFORMATION PROCESSING STANDARD (FIPS) 199, STANDARDS FOR SECURITY Information Technology Laboratory National Institute of Standards and Technology A new Federal Information Processing Standard (FIPS), recently approved by the Secretary of Commerce, will help federal agencies

250

Building Stones  

E-Print Network [OSTI]

3). Photographs by the author. Building Stones, Harrell, UEEOxford Short Citation: Harrell, 2012, Building Stones. UEE.Harrell, James A. , 2012, Building Stones. In Willeke

2012-01-01T23:59:59.000Z

251

Energy Department Announces Winner of the 2013 Better Buildings...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Buildings Federal Award challenges agencies to achieve the greatest reduction in annual energy intensity, or energy consumed per gross square foot. This year's winner cut its...

252

Building Access Policy Responsible Administrative Unit: Finance & Administration  

E-Print Network [OSTI]

Page 1 of 5 1.0 BACKGROUND AND PURPOSE This policy establishes guidelines for facilitating access and thoughtfully controlled as a campus security measure. The desired outcomes for this policy are to streamline

253

EMCS and time-series energy data analysis in a large government office building  

SciTech Connect (OSTI)

Energy Management Control System (EMCS) data are an underutilized source of information on the performance of commercial buildings. Newer EMCS's have the ability and storage capacity to trend large amounts of data and perform preliminary analyses; however, these features often receive little or no use, as operators are generally not trained in data management, visualization, and analysis. Whole-building hourly electric-utility data are another readily available and underutilized source of information. This paper outlines the use of EMCS and utility data to evaluate the performance of the Ronald V. Dellums Federal Building in Oakland, California, a large office building operated by the Federal General Services Administration (GSA). The project began as an exploratory effort at Lawrence Berkeley National Laboratory (LBNL) to examine the procedures operators were using to obtain information and operate their buildings. Trending capabilities were available, but in limited use by the operators. LBNL worked with the building operators to use EMCS to trend one-minute data for over one-hundred points. Hourly electricity-use data were also used to understand usage patterns and peak demand. The paper describes LBNL's key findings in the following areas: Characterization of cooling plant operations; Characterization of economizer performance; Analysis of annual energy use and peak demand operations; Techniques, strengths, and shortcomings of EMCS data analysis; Future plans at the building for web-based remote monitoring and diagnostics. These findings have helped GSA develop strategies for peak demand reduction in this and other GSA buildings. Such activities are of great interest in California and elsewhere, where electricity reliability and demand are currently problematic. Overall, though the building's energy use is fairly low, significant energy savings are available by improving the existing EMCS control strategies.

Piette, Mary Ann; Kinney, Satkartar; Friedman, Hannah

2001-04-01T23:59:59.000Z

254

2013 Building Technologies Office Program Peer Review Report...  

Broader source: Energy.gov (indexed) [DOE]

(SOM) used EnergyPlus to design a new 380,000 square foot federal office building in West Virginia. The building has an advanced ventilated double facade and uses low-energy...

255

A Meta-Analysis of Energy Savings from Lighting Controls in Commercial Buildings  

E-Print Network [OSTI]

daylighting control for low energy buildings. Proceedings ofAIVC Conference on Building Low Energy Cooling and Advancedlow, federal energy conservation standards do not include lighting controls, and state and local building

Williams, Alison

2012-01-01T23:59:59.000Z

256

Federal Laboratory Technology Transfer  

E-Print Network [OSTI]

Federal Laboratory Technology Transfer Fiscal Year 2007 Prepared by: National Institute to present to the President and the Congress this Federal Laboratory Technology Transfer Report summarizing the achievements of Federal technology transfer and partnering programs of the Federal research and development

Perkins, Richard A.

257

Federal Resume Guide  

Broader source: Energy.gov [DOE]

This Learning Module will offer helpful tips and suggestions on the development of a federal resume.

258

International Programs and Services 200 Administration Building  

E-Print Network [OSTI]

/ibrs/uhttps://travelregistration.state.gov/ibrs/u i/ #12;Power of attorney (refer to handout)Power of attorney (refer to handout) Cash plan Emergency cards (front and back) · Power of attorneyPower of attorney · Phone numbers of banks and credit card · How people respond to itHow people respond to it #12;What is the host country's attitude

259

GENERAL SERVICES ADMINISTRATION PUBLIC BUILDINGS SERVICE  

E-Print Network [OSTI]

8. SALARIES 9. FUEL ("x" one) OIL GAS COAL ELECTRIC 10. SYSTEM MAINTENANCE AND REPAIR C. ELECTRICAL/OR MANAGER 23. SECURITY (Watchmen, guards, not janitors) 24. SOCIAL SECURITY TAX AND WORKMEN'S COMPENSATION

260

Energy Information Administration (EIA)- Commercial Buildings Energy  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines AboutDecember 2005 (Thousand9,0, 1997Environment >7, 199930, 20005,6,

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Energy Information Administration (EIA)- Commercial Buildings Energy  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines AboutDecember 2005 (Thousand9,0, 1997Environment >7, 199930, 20005,6,Consumption

262

Energy Information Administration (EIA)- Commercial Buildings Energy  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines AboutDecember 2005 (Thousand9,0, 1997Environment >7, 199930,

263

Energy Information Administration (EIA)- Commercial Buildings Energy  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines AboutDecember 2005 (Thousand9,0, 1997Environment >7, 199930,Consumption Survey (CBECS)

264

Energy Information Administration (EIA)- Commercial Buildings Energy  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines AboutDecember 2005 (Thousand9,0, 1997Environment >7, 199930,Consumption Survey

265

Energy Information Administration (EIA)- Commercial Buildings Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation ProposedUsing Zirconia Nanoparticles asSecondCareer AwardsWashington, 0Consumption Survey

266

Energy Information Administration (EIA)- Commercial Buildings Energy  

Gasoline and Diesel Fuel Update (EIA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"Click worksheet9,1,50022,3,,,,6,1,,781 2,328 2,683Diesel pricesArkansas56,4/15/2015Consumption

267

Drug-Free Federal Workplace Testing Implementation Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The order provides guidance and policy for the administration, application and implementation of the DOE Drug-free Federal Workplace Plan and other regulations that facilitate the maintenance of a drug-free Federal workplace through the establishment of programs to test for the use of illegal drugs. Chg 1, dated 8-21-92

1988-07-29T23:59:59.000Z

268

FORESTRY BUILDING: BUILDING EMERGENCY PLAN  

E-Print Network [OSTI]

FORESTRY BUILDING: BUILDING EMERGENCY PLAN Date Adopted: August 18, 2009 Date Revised June 17, 2013 Prepared By: Diana Evans and Jennifer Meyer #12;PURDUE UNIVERSITY BUILDING EMERGENCY PLAN VERSION 3 2 Table Suspension or Campus Closure SECTION 3: BUILDING INFORMATION 3.1 Building Deputy/Alternate Building Deputy

269

ADMINISTRATIVE RECORDS SCHEDULE 23: ADMINISTRATIVE RECORDS SCHEDULE...  

Broader source: Energy.gov (indexed) [DOE]

ADMINISTRATIVE RECORDS SCHEDULE 23: RECORDS COMMON TO MOST OFFICES ADMINISTRATIVE RECORDS SCHEDULE 23: ADMINISTRATIVE RECORDS SCHEDULE 23: RECORDS COMMON TO MOST OFFICES This...

270

Energy Information Administration - Commercial Energy Consumption...  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

sum to totals. Source: Energy Information Administration, Office of Energy Markets and End Use, Forms EIA-871A, C, and E of the 2003 Commercial Buildings Energy Consumption Survey....

271

Federal Compensation to Idaho for Public Domain Federal Lands, 1988-99 FederalCompensationtoIdaho  

E-Print Network [OSTI]

........................................................................................................ 9 Figure 7. Bingham County Federal Payments........................................................................................................ 12 Figure 15. Canyon County Federal Payments

O'Laughlin, Jay

272

Historic Building Renovations  

Broader source: Energy.gov [DOE]

When a Federal agency undertakes a renovation to an historic building, the renovation team must consider not only the uses and needs of the facility, but also a range of issues related to historic preservation. Integrating renewable energy such as solar and wind into an historic renovation has been accomplished successfully by agencies; the design and placement of any renewable energy system must be closely integrated with the overall design plans. Any renewable energy additions must maintain the integrity and defining characteristics of the building.

273

Fuel Cells Meeting: Matching Federal Government Needs with Energy  

E-Print Network [OSTI]

Fuel Cells Meeting: Matching Federal Government Needs with Energy Efficient Fuel Cells Hosted MORNING 9:00 - 9:10 a.m. Welcoming Remarks Schuyler Schell, Federal Energy Management Program Jo Council 9:10 - 10:40 a.m. Buildings and Facility Power Keith Spitznagel, LOGANEnergy Portable and Back

274

New MOX Conservation Garden Features Federally Endangered Plant  

E-Print Network [OSTI]

is located, has been certified as a Leadership in Energy and Environmental Design (LEED) Gold buildingNew MOX Conservation Garden Features Federally Endangered Plant Linda Lee, botanist for the Savannah River Ecology Lab (from left), Clay Ramsey , federal project director of the Mixed Oxide Fuel

Georgia, University of

275

_q_ (_/._ ' December 1992 Analysisof Federal Policy(ptions for  

E-Print Network [OSTI]

_¢q_ (_/._ ' December 1992 Analysisof Federal Policy(ptions for Improving U.S.LightingEnergy employer. #12;Analysis of Federal Policy Options for Improving U.S. Lighting Energy Efficiency: Commercial the AssistantSecretaryfor ConservationandRenewableEnergy,Office of Building Technologiesof the

276

BUILDING NAME HEYDON-LAURENCE BUILDING  

E-Print Network [OSTI]

BUILDING NAME HEYDON-LAURENCE BUILDING PHARMACY AND BANK BUILDING JOHN WOOLEY BUILDING OLD TEARCHER'S BUILDING PHYSICS BUILDING BAXTER'S LODGE INSTITUTE BUILDING CONSERVATION WORKS R.D.WATT BUILDING MACLEAY BUILDING THE QUARANGLE BADHAM BUILDING J.D. STEWART BUILDING BLACKBURN BUILDING MADSEN BUILDING STORE

Viglas, Anastasios

277

Hempstead Rd FederalHeightsDr.  

E-Print Network [OSTI]

WolcottSt 2030 East Hempstead Rd FederalHeightsDr. MedicalDr. North 100 South ConnorRd Red Butte Canyon Rd W asatch D r. FortDouglasBlvd UniversityStreet W akaraW ay 500 South North Campus Dr. North Care ACC Parking Terrace Eccles Business Building Health Professions Merrill Engineering The Children

Tipple, Brett

278

Federal Recycling Program Printed on recycled paper.  

E-Print Network [OSTI]

#12;Federal Recycling Program Printed on recycled paper. The Forest Health Technology Enterprise of discrimination, write USDA, Director, Office of Civil Rights, Room 326-W, Whitten Building, 1400 independence MALEZAS POR ENEMIGOS NATURALES R. G. VAN DRIESCHE University of Massachusetts Amherst, Massachusetts, USA

Hoddle, Mark S.

279

Presented at the International Conference for Enhanced Building Operations, July 16-19, 2001 in Austin, TX This work was partially supported by the U.S. General Services Administration, the California Energy Commission,  

E-Print Network [OSTI]

and Weather Sensitivity in Large California Commercial Office Buildings Satkartar Kinney, Mary Ann Piette;Demand Relief and Weather Sensitivity in Large California Commercial Office Buildings Satkartar Kinney of research has examined the weather sensitivity of energy consumption in commercial buildings; however

280

Building the ADCIRC Collaborative  

E-Print Network [OSTI]

Building the ADCIRC Collaborative A federated approach to storm surge modeling and model output distribution to enable better decision support C O N T A C T I N F O R M A T I O N Brian Blanton Telephone: 919.445.9620 Email: brian_blanton@renci.org A R E N C I W H I T E P A P E R #12;Page 2 At a Glance

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Executive Order 13514: Federal Leadership in Environmental, Energy, and Economic Performance; Comprehensive Federal Fleet Management Handbook (Book)  

SciTech Connect (OSTI)

A comprehensive Federal Fleet Management Handbook that builds upon the "Guidance for Federal Agencies on E.O. 13514 Section 12-Federal Fleet Management" and provides information to help fleet managers select optimal greenhouse gas and petroleum reduction strategies for each location, meeting or exceeding related fleet requirements, acquiring vehicles to support these strategies while minimizing fleet size and vehicle miles traveled, and refining strategies based on agency performance.

Daley, R.; Ahdieh, N.; Bentley, J.

2014-01-01T23:59:59.000Z

282

Background to the development process, Automated Residential Energy Standard (ARES) in support of proposed interim energy conservation voluntary performance standards for new non-federal residential buildings: Volume 3  

SciTech Connect (OSTI)

This report documents the development and testing of a set of recommendations generated to serve as a primary basis for the Congressionally-mandated residential standard. This report treats only the residential building recommendations.

NONE

1989-09-01T23:59:59.000Z

283

Recommendations and Justifications for Modifications for Use Restrictions Established under the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office Federal Facility Agreement and Consent Order with ROTC 1, Revision No. 0  

SciTech Connect (OSTI)

Many Federal Facility Agreement and Consent Order (FFACO) Use Restrictions (URs) have been established at various corrective action sites (CASs) as part of FFACO corrective actions (FFACO, 1996; as amended January 2007). Since the signing of the FFACO in 1996, practices and procedures relating to the implementation of risk-based corrective action (RBCA) have evolved. This document is part of an effort to re-evaluate all FFACO URs against the current RBCA criteria (referred to in this document as the Industrial Sites [IS] RBCA process) as defined in the Industrial Sites Project Establishment of Final Action Levels (NNSA/NSO, 2006c). Based on this evaluation, the URs were sorted into the following categories: 1. Where sufficient information exists to determine that the current UR is consistent with the RCBA criteria 2. Where sufficient information exists to determine that the current UR may be removed or downgraded based on RCBA criteria. 3. Where sufficient information does not exist to evaluate the current UR against the RCBA criteria. After reviewing all the existing FFACO URs, the 49 URs addressed in this document have sufficient information to determine that these current URs may be removed or downgraded based on RCBA criteria. This document presents recommendations on modifications to existing URs that will be consistent with the RCBA criteria.

Lynn Kidman

2008-02-01T23:59:59.000Z

284

Around Buildings  

E-Print Network [OSTI]

Around Buildings W h y startw i t h buildings and w o r k o u t wa r d ? For one, buildings are difficult t o a v o i d these

Treib, Marc

1987-01-01T23:59:59.000Z

285

BUILDING INSPECTION Building, Infrastructure, Transportation  

E-Print Network [OSTI]

BUILDING INSPECTION Building, Infrastructure, Transportation City of Redwood City 1017 Middlefield Sacramento, Ca 95814-5514 Re: Green Building Ordinance and the Building Energy Efficiency Standards Per of Redwood City enforce the current Title 24 Building Energy Efficiency Standards as part

286

Building Name 100 Antoinette 191 DTE  

E-Print Network [OSTI]

2-Jul-13 Building Name Bldg No Utility 100 Antoinette 191 DTE 1011 Ferry East 527 DTE 110 E. Warren Hancock West 074 DTE Academic/Administrative Building 062 DTE Alex Manoogian Hall 155 PLD Alumni House 042 PLD Art Building 040 PLD Atchison (South) Hall 104 DTE Athletic Multi-purpose Indoor Facility 091 PLD

Cinabro, David

287

Federal Agency NEPA Procedures  

Broader source: Energy.gov [DOE]

Each Federal agency is required to develop NEPA procedures that supplement the CEQ Regulations. Developed in consultation with CEQ, Federal agency NEPA procedures must meet the standards in the CEQ...

288

Federated Clusters Using the Transparent Remote Execution (TREx) Environment  

E-Print Network [OSTI]

Federated Clusters Using the Transparent Remote Execution (TREx) Environment Richert Wang1 University of California, Irvine 442 Computer Science Building Irvine, CA 92697-3435 rkwang@ics.uci.edu Enrique Cauich University of California, Irvine 442 Computer Science Building Irvine, CA 92697

Scherson, Isaac D.

289

Research and Practice in Federated Information Systems Report of the EFIS '2000 International Workshop  

E-Print Network [OSTI]

for federated system integration, and the use of meta- directories in building federations. DetailsResearch and Practice in Federated Information Systems Report of the EFIS '2000 International Workshop W. Hasselbring W.-J. van den Heuvel y G.J. Houben z R.-D. Kutsche x B. Rieger M. Roantree k K

Houben, Geert-Jan

290

ESPC Sucess Story- Harold Washington Social Security Administration Center  

Broader source: Energy.gov [DOE]

Fact sheet describes the Federal Energy Management Program (FEMP) Energy Savings Performance Contract (ESPC) success story on environmental stewardship and cost savings at the Harold Washington Social Security Administration Center in Chicago, Illinois.

291

Foundations 6% Federal 49%  

E-Print Network [OSTI]

Administration National Renewable Energy Laboratory National Science Foundation National Security Agency Naval Agencies Administration for Children and Families Air Force Office of Scientific Research Air Force Administration Lawrence Livermore National Laboratory NASA Headquarters NASA Jet Propulsion Laboratory National

Ponce, V. Miguel

292

FEDERAL ENERGY REGULATORY COMMISSION  

E-Print Network [OSTI]

FEDERAL ENERGY REGULATORY COMMISSION WASHINGTON, D.C. 20426 NEWS RELEASE NEWS MEDIA CONTACT POWER MARKETS The Federal Energy Regulatory Commission today ordered its staff to conduct investigators will find out if any technical or operational factors, federal or state regulatory prohibitions

Laughlin, Robert B.

293

Federal Employee Training Manual  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Manual provides detailed requirements to supplement DOE O 360.1B, FEDERAL EMPLOYEE TRAINING. The information in this Manual is intended to assist in improving Federal workforce performance under Department of Energy (DOE) managed Federal employee training. Cancels DOE M 360.1A-1. Canceled by DOE O 360.1C.

2001-10-11T23:59:59.000Z

294

Federal Employee Training Manual  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Manual provides detailed requirements to supplement DOE O 360.1A, Federal Employee Training, dated 9-21-99. The information in this Manual is intended to assist in improving Federal workforce performance under Department of Energy (DOE) managed Federal employee training. Canceled by DOE M 360.1-1B.

1999-09-21T23:59:59.000Z

295

Federal Government Presence in  

E-Print Network [OSTI]

% since 1993 Source: Statistics Canada, Public Sector Employment, Table 183-0002. Figure 4 Federal of Federal Employment Source: Statistics Canada, Public Sector Employment, Table 183-0002. Figure 6 Federal #12;Employment Shares Across Provinces Source: Statistics Canada, Population, Table 51-0001 and Public

deYoung, Brad

296

Thermal Energy Storage for Space Cooling--Federal Technology Alert  

SciTech Connect (OSTI)

Cool storage technology can be used to significantly reduce energy costs by allowing energy-intensive, electrically driven cooling equipment to be predominantly operated during off peak hours when electricity rates are lower. This Federal Technology Alert, which is sponsored by DOE's Federal Energy Management Program (FEMP), describes the basic types of cool storage technologies and cooling system integration options. In addition, it defines the savings potential in the federal sector, presents application advice, and describes the performance experience of specific federal users. The results of a case study of a GSA building using cool storage technology are also provided.

Brown, Daryl R

2000-12-31T23:59:59.000Z

297

Thermal Energy for Space Cooling--Federal Technology Alert  

SciTech Connect (OSTI)

Cool storage technology can be used to significantly reduce energy costs by allowing energy-intensive, electrically driven cooling equipment to be predominantly operated during off peak hours when electricity rates are lower. This Federal Technology Alert, which is sponsored by DOE's Federal Energy Management Program (FEMP), describes the basic types of cool storage technologies and cooling system integration options. In addition, it defines the savings potential in the federal sector, presents application advice, and describes the performance experience of specific federal users. The results of a case study of a GSA building using cool storage technology are also provided.

Brown, Daryl R.

2000-12-31T23:59:59.000Z

298

Metering and the New Federal Requirements of Energy Policy Act 2005  

E-Print Network [OSTI]

agencies to meter electricity use in all federal buildings by Oct. 1, 2012 using advanced meters or metering devices that provide data at least daily. Six months after the enactment of EPAct, DOE’s Federal Energy Management Program, or FEMP... Station, Texas ABSTRACT Section 103 of the Energy Policy Act of 2005 (EPAct 2005) (1) mandates the installation of meters and advanced electric meters on all Federal Buildings by 2012 using guidelines developed by the US Department of Energy...

Ream, A.; Verdict, M.

2006-01-01T23:59:59.000Z

299

Warehouse and Service Building Renovations  

Broader source: Energy.gov [DOE]

Many Federal facilities include warehouses or other buildings used for storage service such as motor pools or groundskeeping, hangars, or other spaces that are frequently open to the outside and have only semi-conditioned spaces. Use of daylighting and solar ventilation preheat are prime technologies for these type of spaces, but other technologies may also warrant consideration.

300

Page 1 of 2 Office of Research Administration  

E-Print Network [OSTI]

with the Government by checking Federal Flow-Through yes or no. Example: If DOE granted funds to Stanford and Stanford or Grant Administrator at ORA. 1. CSM Information: Please fill out this section based on the information. If the funding is not directly from the Federal Government, please indicate whether or not the funds originated

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Bonneville Power Administration 1991 Annual Report.  

SciTech Connect (OSTI)

Congress enacted the Bonneville Project Act in 1937, creating the Bonneville Power Administration to market and transmit the power produced by Bonneville Dam on the Columbia River. Since then, Congress has directed BPA to sell at wholesale the power produced at a total of 30 Federal dams in the Pacific Northwest, and to acquire conservation and generating resources sufficient to meet the needs of BPA`s customer utilities. The dams and the electrical system are known as the Federal Columbia River Power System. Bonneville sells wholesale power to public and private utilities, rural cooperatives, large industries, and Federal agencies. BPA also sells or exchanges power with utilities in California. BPA uses revenues from the sale of power and transmission services to recover its own expenses, to repay the Federal investment in the power system, and to pay for the resources it has acquired. BPA pays for operation and maintenance expenses at the Federal dams and at non-Federal power plants. It also pays for irrigation benefits of Federal projects allocated to power to repay, and for fish and wildlife projects which offset damage to these resources by the Federal hydropower system. This document is the 1991 statement of budget, financial statement, cash flows, capitalization, expenses, and projects. An organization chart is included.

United States. Bonneville Power Administration.

1992-01-01T23:59:59.000Z

302

Administration& Engineering  

E-Print Network [OSTI]

Row 3 Site 3.4 Site 3.3 Site 4.4 Site 4.5 Site 4.1 Site 4.0 4.0 Met Tower Administration& Engineering Bldg. 251 OfficeTrailer Bldg.250 OfficeTrailer Bldg.249OfficeTrailer Bldg.248 251 Parking W. 120th Ave. W. 119th Ave. 4.1 Met Tower 4.4 Met Tower Site 3.1 5-MWDyno Bldg. 258 Site 1.1 Site M1 Structural

303

October 17, 2002 Bonneville Power Administration  

E-Print Network [OSTI]

October 17, 2002 Bonneville Power Administration PO Box 12999 Portland, OR 97208 comment for the post 2006 utility contracts. As a federal entity created to serve the people of its region, Bonneville for the region and stimulate economic growth. Geothermal: Newberry volcano, OR Geothermal power is the natural

304

Practical Alternative Financing Strategies for Building Commissioning  

E-Print Network [OSTI]

Practical Alternative Financing Strategies for Building Commissioning Arun Jhaveri, Regional Manager Federal Energy Management Program U. S. Dept. of Energy/Western Regional Office Seattle, Washington ABSTRACT Owning and operating a... or retro-commissioning of existing buildings/facilities that are going through major retrofit/renovation. In a recent study of some 60 commercial buildings, the Portland Energy Conservation, Inc.(PECI) found the following alarming conditions - i) more...

Zhaveri, A.

2005-01-01T23:59:59.000Z

305

Practical Integration Approach and Whole Building Energy Simulation of Three Energy Efficient Building Technologies: Preprint  

SciTech Connect (OSTI)

Three technologies that have potential to save energy and improve sustainability of buildings are dedicated outdoor air systems, radiant heating and cooling systems and tighter building envelopes. To investigate the energy savings potential of these three technologies, whole building energy simulations were performed for a barracks facility and an administration facility in 15 U.S. climate zones and 16 international locations.

Miller, J. P.; Zhivov, A.; Heron, D.; Deru, M.; Benne, K.

2010-08-01T23:59:59.000Z

306

Sustainable Infrastructure Practices -Green Building Design, page 1 of 2 UC SANTA BARBARA  

E-Print Network [OSTI]

Sustainable Infrastructure Practices - Green Building Design, page 1 of 2 UC SANTA BARBARA Sustainable Infrastructure Practices - Green Building Design Contact: Administrative Services Revision: Effective July 1, 2012 Supersedes Green Building Design Interim Policy: June1, 2010 through June 30, 2012

Bigelow, Stephen

307

TITLE: Integrated Building Energy Efficiency HOSTS: Howard Chong, Brandon Hencey, and Kenneth Schlather  

E-Print Network [OSTI]

sustainable buildings research come out of many departments including Architecture, Computer Science, Design on building energy efficiency. Facilities Services, which has a strong team on Energy and Sustainability and Environmental Analysis (DEA), Economics, Engineering, and Hotel Administration. Sustainable buildings represent

Angenent, Lars T.

308

Computer Systems Administrator  

E-Print Network [OSTI]

Computer Systems Administrator Fort Collins, CO POSITION A Computer Systems Administrator (Non activities. RESPONSIBILITIES The System Administrator will provide Unix/Linux, Windows computer system or computer science, and three years computer systems administration experience. DURATION The work is planned

309

Here are Some Helpful Resources From the IRB Administration Office...  

E-Print Network [OSTI]

Here are Some Helpful Resources From the IRB Administration Office... The IRB Administration Office Training and Helpful Tools Our Website has the on-going training calendar (1 a week); helpful tools, resources and documents; policies; and helpful links to federal agencies: http

Finley Jr., Russell L.

310

Building America  

SciTech Connect (OSTI)

IBACOS researched the constructability and viability issues of using high performance windows as one component of a larger approach to building houses that achieve the Building America 70% energy savings target.

Brad Oberg

2010-12-31T23:59:59.000Z

311

Federal Employee Health Services  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The order establishes requirements and responsibilities for occupational medical, employee assistance, and workers' compensation programs for Federal employees. Cancels DOE O 341.1.

2007-10-18T23:59:59.000Z

312

From Federal Computer Week:  

National Nuclear Security Administration (NNSA)

Federal Computer Week: Energy agency launches performance-based pay system By Richard W. Walker Published on March 27, 2008 The Energy Department's National Nuclear Security...

313

Federal NEPA Contacts  

Broader source: Energy.gov [DOE]

CEQ and most Federal agencies identify primary points of contact for NEPA compliance. Normally a senior environmental professional, environmental law attorney, or member of agency leadership, these...

314

Building technologies  

ScienceCinema (OSTI)

After growing up on construction sites, Roderick Jackson is now helping to make buildings nationwide far more energy efficient.

Jackson, Roderick

2014-07-15T23:59:59.000Z

315

Building technologies  

SciTech Connect (OSTI)

After growing up on construction sites, Roderick Jackson is now helping to make buildings nationwide far more energy efficient.

Jackson, Roderick

2014-07-14T23:59:59.000Z

316

National Nuclear Security Administration  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

FROM: SUBJECT: USIUK Memorandum of Understanding between National Nuclear Security Administration's (NNSA) Associate Administrator for Defense Nuclear Security (AADNS)...

317

Twitter Training for Small Business Federal Contractors  

Broader source: Energy.gov [DOE]

Twitter can be used to raise brand awareness, share and obtain information on upcoming federal contract opportunities, to network with peers and government leaders, and to help build a reputation for expertise in your field. Put Twitter to work for you! If you are already on Twitter, just getting started on Twitter, or thinking of joining, you can get super ideas on how to make a positive impression, discover more opportunities, team with colleagues, and drive business growth.

318

Beardmore Building  

High Performance Buildings Database

Priest River, ID Originally built in 1922 by Charles Beardmore, the building housed offices, mercantile shops, a ballroom and a theater. After decades of neglect under outside ownership, Brian Runberg, an architect and great-grandson of Charles Beardmore, purchased the building in 2006 and began an extensive whole building historic restoration.

319

Bonneville Power Administration Administrator Steve Wright  

E-Print Network [OSTI]

Administrator Steve Wright, I strongly support a clean energy future for our region that includes plentiful wild salmon, clean, renewable energy, and a healthy economy. The Bonneville Power Administration (BPABonneville Power Administration Administrator Steve Wright PO Box 12999 Portland, OR 97208 Dear

320

Additional Resources for Estimating Building Energy and Cost Savings to Reduce Greenhouse Gases  

Broader source: Energy.gov [DOE]

For evaluating greenhouse gas reduction strategies and estimating costs, the following information resources can help Federal agencies estimate energy and cost savings potential by building type.

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Building Name BuildingAbbr  

E-Print Network [OSTI]

Capture/InstrCam ClassroomCapture/TechAsst SkypeWebcam NOTES for R&R Only Room Detail Building Times Weekend and Evening BldgBuilding Name BuildingAbbr RoomNumber SeatCount DepartmentalPriority SpecialNeedsSeating Special Detail Building Contacts Event Scheduling Detail BI 02010 104 NR Y 52 61 81 84 85 86 87 88 89 90 91 92 94

Parker, Matthew D. Brown

322

Energy Efficiency Standards for State Buildings  

Broader source: Energy.gov [DOE]

Arizona has some requirements for their buildings contained within their statutes. A.R.S. § 34-451 requires the Department of Administration, the Department of Transportation and the Arizona Board...

323

Federal Technical Capability Manual  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Federal Technical Capability Manual provides the process for the recruitment, deployment, development, and retention of Federal personnel with the demonstrated technical capability to safely accomplish the Departments missions and responsibilities at defense nuclear facilities. Canceled by DOE M 426.1-1A. Does not cancel other directives.

2000-06-05T23:59:59.000Z

324

Federal Technical Capability  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This directive defines requirements and responsibilities for meeting the Department of Energy (DOE) commitment to recruiting, deploying, developing, and retaining a technically competent workforce that will accomplish DOE missions in a safe and efficient manner through the Federal Technical Capability Program (FTCP). Cancels DOE M 426.1-1A, Federal Technical Capability Manual.

2009-11-19T23:59:59.000Z

325

FEDERAL ENERGY REGULATORY COMMISSION  

E-Print Network [OSTI]

FEDERAL ENERGY REGULATORY COMMISSION WASHINGTON, D.C. 20426 NEWS RELEASE NEWS MEDIA CONTACT AND FERC STAFF The Federal Energy Regulatory Commission today accepted a settlement, valued at nearly $500 stemming from the 2000-2001 energy crisis in California and other Western states. The global settlement

Laughlin, Robert B.

326

FEDERAL ENERGY REGULATORY COMMISSION  

E-Print Network [OSTI]

FEDERAL ENERGY REGULATORY COMMISSION WASHINGTON, D.C. 20426 NEWS RELEASE NEWS MEDIA CONTACT SETTLEMENT BETWEEN DUKE AND COMMISSION STAFF The Federal Energy Regulatory Commission today accepted a settlement between the Commission's enforcement staff and Houston-based units of Duke Energy that resolves

Laughlin, Robert B.

327

FEDERAL ENERGY REGULATORY COMMISSION  

E-Print Network [OSTI]

FEDERAL ENERGY REGULATORY COMMISSION WASHINGTON, D.C. 20426 NEWS RELEASE NEWS MEDIA CONTACT POWER EXCHANGE MARKET The Federal Energy Regulatory Commission today approved a staff settlement calling-2-001 COMMISSION APPROVES $13.8 MILLION SETTLEMENT WITH RELIANT ENERGY OVER PHYSICAL WITHHOLDING IN CALIFORNIA

Laughlin, Robert B.

328

FEDERAL ENERGY REGULATORY COMMISSION  

E-Print Network [OSTI]

FEDERAL ENERGY REGULATORY COMMISSION WASHINGTON, D.C. 20426 NEWS RELEASE NEWS MEDIA CONTACT The Federal Energy Regulatory Commission today accepted an agreement between Nevada Power and Sierra Pacific. AGREEMENT ACCEPTED BETWEEN ENRON AND NEVADA COMPANIES SETTLING MATTERS STEMMING FROM WESTERN ENERGY CRISIS

Laughlin, Robert B.

329

FEDERAL ENERGY REGULATORY COMMISSION  

E-Print Network [OSTI]

FEDERAL ENERGY REGULATORY COMMISSION WASHINGTON, D.C. 20426 NEWS RELEASE NEWS MEDIA CONTACT FERC APPROVES SETTLEMENT WITH RELIANT IN CALIFORNIA CASES; PROCEEDS COULD TOTAL $50 MILLION The Federal Energy Regulatory Commission today approved a settlement between the Commission's enforcement staff

Laughlin, Robert B.

330

FEDERAL ENERGY REGULATORY COMMISSION  

E-Print Network [OSTI]

FEDERAL ENERGY REGULATORY COMMISSION WASHINGTON, D.C. 20426 NEWS RELEASE NEWS MEDIA CONTACT CRISIS The Federal Energy Regulatory Commission today approved a comprehensive settlement among APX Inc. Coral Power LLC, Puget Sound Energy Inc. and Avista are Supporting Parties. R-07-14 (30) #12;

Laughlin, Robert B.

331

FEDERAL ENERGY REGULATORY COMMISSION  

E-Print Network [OSTI]

FEDERAL ENERGY REGULATORY COMMISSION WASHINGTON, D.C. 20426 NEWS RELEASE NEWS MEDIA CONTACT-95-191 COMMISSION APPROVES TWO WESTERN POWER SETTLEMENTS The Federal Energy Regulatory Commission today approved two markets during the Western energy crisis of 2000-2001. The first case involves a settlement agreement

Laughlin, Robert B.

332

Advanced Metering Implementations - A Perspective from Federal Sector  

SciTech Connect (OSTI)

Federal mandate (EPACT 2005) requires that federal buildings install advanced electrical meters-meters capable of providing data at least daily and measuring the consumption of electricity at least hourly. This work presents selected advanced metering implementations to understand some of the existing practices related to data capture and to understand how the data is being translated into information and knowledge that can be used to improve building energy and operational performance to meet federal energy reduction mandates. This study highlights case studies to represent some of the various actions that are being taken based on the data that are being collected to improve overall energy performance of these buildings. Some of these actions include- individualized tenant billing and energy forecasting, benchmarking, identifying energy conservation measures, measurement and verification.

Eaarni, Shankar

2014-08-11T23:59:59.000Z

333

Electricity Advisory Committee - Federal Register Notices | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Federal Register Notices Electricity Advisory Committee - Federal Register Notices Electricity Advisory Committee - Federal Register Notices September 3, 2014 Electricity Advisory...

334

Tax Deduction Qualified Software- Green Building Studio Web Service version 3.4  

Broader source: Energy.gov [DOE]

Information about the Green Building Studio Web Service version 3.4 qualified computer software, which calculates energy and power cost savings that meet federal tax incentive requirements for commercial buildings.

335

administration federal highway: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

traffic flow control in automated highway systems Luis Alvarez a,*, Roberto 13 October 1999; accepted 8 April 2002 Abstract Traffic flow control in automated highway systems...

336

Federal Highway Administration Long-Term Bridge Performance Program  

E-Print Network [OSTI]

deterioration models and life-cycle cost analysis ·! Support for development of the next generation of Bridge Management Systems #12;Step 1 Defining Bridge Performance Step 2 Data to be Collected Step 3 Data Management System Step 4 Design the Experimental Program Step 5 Data Collection Program Outcome Step 6 Data Analysis

Minnesota, University of

337

The Federal Trade Commission: administrative discretion and congressional oversight  

E-Print Network [OSTI]

jurisdiction, these findings for the FTC should be extended to other independent regulatory commissions with due caution. ACKNOWLEDGEMENTS This study developed out of coursework taken under my Committee Chairman, Dr. Jon R. Bond, and a member of my... coercion "to prevent individual conduct from transcending acceptable bounds. " To enforce the myriad legal restrict- ions on economic and social conduct, mechanisms of government, such as the independent regulatory commissions, have been established...

Harris, Ronald Alan

1980-01-01T23:59:59.000Z

338

Obama Administration Officials to Announce Major Steps toward Federal  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAXBalanced ScorecardReactor TechnologyOFFICE: I Oak Ridge,8 8 8 , ,withPilot

339

Secretaries Chu and Salazar Lead Administration Team Offering Federal  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power.pdf11-161-LNG |September2-SCORECARD-01-24-13 Page 1 ofIBRF Project$17.5 MillionScientific

340

Federal Transit Administration-National Transit Database (NTD) | Open  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating Solar Power Basics (TheEtelligence (Smart GridHome

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

File:Federal Hydropower - Southwestern Power Administration.pdf | Open  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision has beenFfe2fb55-352f-473b-a2dd-50ae8b27f0a6 NoSanEnergy0).pdf JumpEnergy Information Southwestern

342

Federal Highway Administration - Pilot Car Escort - Best Practices  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address:011-DNA Jump37.California: Energy Resources44795°,FauquierGrant Program JumpGuidelines |

343

Matching Federal Government EnergyMatching Federal Government Energy Needs with Energy Efficient Fuel CellsNeeds with Energy Efficient Fuel Cells  

E-Print Network [OSTI]

1 Matching Federal Government EnergyMatching Federal Government Energy Needs with Energy Efficient Fuel CellsNeeds with Energy Efficient Fuel Cells Keith A SpitznagelKeith A Spitznagel Senior VP Buildings & Facilities · 5 Kilowatts to Megawatts Speciality vehicles & Material handling · 1 to 50

344

Federal Activities in the Bioeconomy  

Broader source: Energy.gov [DOE]

Plenary V: Federal Activities in the Bioeconomy Federal Activities in the Bioeconomy Zia Haq, Senior Analyst, Technology Manager, Bioenergy Technologies Office, U.S. Department of Energy

345

Building Stones  

E-Print Network [OSTI]

was no good source of local building stone, rock was usuallyrock-cut shrines and especially tombs, and these are the sources

2012-01-01T23:59:59.000Z

346

Mathematics/Geosciences Building Renovation Limits Access and Parking The Southeast entrance to the Mathematics/Geosciences Building and 20 parking spaces in the  

E-Print Network [OSTI]

Mathematics/Geosciences Building Renovation Limits Access and Parking The Southeast entrance to the Mathematics/Geosciences Building and 20 parking spaces in the Administration Visitor Lot will be closed, and in the Administration Visitor Lot, through August. The Mathematics/Geosciences Building renovation includes considerable

Barrash, Warren

347

Update of Market Assessment for Capturing Water Conservation Opportunities in the Federal Sector  

SciTech Connect (OSTI)

This updated market assessment for capturing water conservation opportunities in the Federal sector is based on a new analytical approach that utilizes newly available data and technologies. The new approach fine-tunes the original assessment by using actual Federal water use, which is now tracked by DOE (as compared to using estimated water use). Federal building inventory data is also used to disseminate water use by end-use technology in the Federal sector. In addition, this analysis also examines the current issues and obstacles that face performance contracting of water efficiency projects at Federal sites.

Mcmordie, Katherine; Solana, Amy E.; Elliott, Douglas B.; Sullivan, Gregory P.; Parker, Graham B.

2005-09-08T23:59:59.000Z

348

Federal Water Use Indices  

Broader source: Energy.gov [DOE]

FEMP provides water use indices as a guide for Federal agencies. Note that each is a rough estimate of water usage at different types of sites. Your site may vary considerably.

349

Federal Employee Health Services  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To establish requirements and responsibilities for occupational medical, employee assistance, and workers' compensation programs for Federal employees. Cancels DOE 3790.1B. Canceled by DOE O 341.1A.

2003-12-01T23:59:59.000Z

350

Federal Protective Force  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Manual establishes requirements for the management and operation of the Department of Energy (DOE) Federal protective forces (FPFs). Cancels DOE M 470.4-3, Chg 1. Canceled by DOE O 473.3.

2009-07-15T23:59:59.000Z

351

Energy Efficiency Evaluation and Planning for Existing Buildings  

Broader source: Energy.gov [DOE]

For meeting Federal sustainability requirements, agencies can use evaluation methods—such as benchmarking and energy audits—and planning to make their existing buildings energy efficient. To comply...

352

Finance & Administration Controller's Office  

E-Print Network [OSTI]

Finance & Administration Controller's Office July 2014 Michael Williams Controller Controller Administrative Services 51111 Catherine Hebert Program Director ICOFA 61318 Revised: 7/28/2014 #12;Finance Surplus Property 81269 Revised: 7/28/2014 #12;Finance & Administration Controller's Office Disbursement

McQuade, D. Tyler

353

Finance & Administration Controller's Office  

E-Print Network [OSTI]

Finance & Administration Controller's Office April 2014 Michael Williams Controller Controller ICOFA 61318 Revised: 4/4/2014 #12;Finance & Administration Controller's Office Accounting & Asset Coordinator Property Surplus Sales 81269 Revised: 4/4/2014 #12;Finance & Administration Controller's Office

Weston, Ken

354

Sales of Fossil Fuels Produced from Federal and Indian Lands, FY 2003 through FY 2011  

Broader source: Energy.gov [DOE]

This paper was prepared in response to recent requests that the U.S. Energy Information Administration (EIA) provide updated summary information regarding fossil fuel production on federal and...

355

ADMINISTRATIVE RECORDS SCHEDULE 2: PAYROLL AND PAY ADMINISTRATION...  

Broader source: Energy.gov (indexed) [DOE]

: PAYROLL AND PAY ADMINISTRATION RECORDS ADMINISTRATIVE RECORDS SCHEDULE 2: PAYROLL AND PAY ADMINISTRATION RECORDS Payrolling and pay administration records pertain to the...

356

ADMINISTRATIVE RECORDS SCHEDULE 2: PAYROLL AND PAY ADMINISTRATION...  

Broader source: Energy.gov (indexed) [DOE]

2: PAYROLL AND PAY ADMINISTRATION RECORDS-Revision 2 ADMINISTRATIVE RECORDS SCHEDULE 2: PAYROLL AND PAY ADMINISTRATION RECORDS-Revision 2 Payrolling and pay administration records...

357

National Nuclear Security Administration  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Project Reviews, etc., except those specifically reserved for the Administrator for the National Nuclear Security Administration and the Deputy Secretary. cc: Mike Hickman. NA-Stl...

358

Source: Federal Emergency Management Agency September 2011 Earthquake Preparedness at NC State  

E-Print Network [OSTI]

Source: Federal Emergency Management Agency September 2011 Earthquake Preparedness at NC State buildings. Be aware, the electricity may go out or the sprinkler systems or fire alarms may turn on

359

Design/installation and structural integrity assessment under the Federal Facility Agreement for Bethel Valley Low-Level Waste Collection and Transfer System upgrade for Building 2026 (High Radiation Level Analytical Laboratory) and Building 2099 (Monitoring and Control Station) at Oak Ridge National Laboratory  

SciTech Connect (OSTI)

This document presents a Design/Installation and Structural Integrity Assessment for a replacement tank system for portions of the Bethel Valley Low Level Waste (LLW) System, located at the Oak Ridge Reservation, Oak Ridge, Tennessee. This issue of the assessment covers the design aspects of the replacement tank system, and certifies that the design has sufficient structural integrity and is acceptable for the storing or treating of hazardous and/or radioactive substances. The present issue identifies specific activities that must be completed during the fabrication, installation, and testing of the replacement tank system in order to provide assurance that the final installation complies with governing requirements. Portions of the LLW system are several decades old, or older, and do not comply with current environmental protection regulations. Several subsystems of the LLW system have been designated to receive a state-of-the-art replacement and refurbishment. One such subsystem serves Building 2026, the High Radiation Level Analytical Laboratory. This assessment focuses on the scope of work for the Building 2026 replacement LLW Collection and Transfer System, including the provision of a new Monitoring and Control Station (Building 2099) to receive, store, and treat (adjust pH) low level radioactive waste.

Not Available

1994-10-01T23:59:59.000Z

360

Federal government information handbook: formerly utilized sites remedial action program  

SciTech Connect (OSTI)

This volume is one of a series produced under contract with the DOE, by Politech Corporation to develop a legislative and regulatory data base to assist the FUSRAP management in addressing the institutional and socioeconomic issues involved in carrying out the Formerly Utilized Sites Remedial Action Program. This Information Handbook series contains information about all relevant government agencies at the Federal and state levels, the pertinent programs they administer, each affected state legislature, and current Federal and state legislative and regulatory initiatives. This volume is a compilation of information about the Federal Government. It contains a summary of the organization and responsibilities of agencies within the executive branch of the Federal government which may be relevant to FUSRAP activities; a brief summary of relevant Federal statutes and regulations; a description of the structure of the US Congress, identification of the officers, relevant committees and committee chairmen; a description of the Federal legislative process; a summary of legislation enacted and considered in the recently-adjourned 96th Congress; a description of the Federal budgetary process; a summary of the Carter Administration's comprehensive radioactive waste management program; and excerpts from the text of relevant federal statutes and regulations.

Not Available

1980-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Building Energy Optimization Analysis Method (BEopt) - Building...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Energy Optimization Analysis Method (BEopt) - Building America Top Innovation Building Energy Optimization Analysis Method (BEopt) - Building America Top Innovation House graphic...

362

Building America Expert Meeting: Transforming Existing Buildings...  

Energy Savers [EERE]

Transforming Existing Buildings through New Media--An Idea Exchange Building America Expert Meeting: Transforming Existing Buildings through New Media--An Idea Exchange This report...

363

Building America Residential Buildings Energy Efficiency Meeting...  

Broader source: Energy.gov (indexed) [DOE]

Residential Buildings Energy Efficiency Meeting: July 2010 Building America Residential Buildings Energy Efficiency Meeting: July 2010 On this page, you may link to the summary...

364

Technology Potential of Thermal Energy Storage (TES) Systems in Federal Facilities  

SciTech Connect (OSTI)

This document presents the findings of a technology market assessment for thermal energy storage (TES) in space cooling applications. The potential impact of TES in Federal facilities is modeled using the Federal building inventory with the appropriate climatic and energy cost data. In addition, this assessment identified acceptance issues and major obstacles through interviews with energy services companies (ESCOs), TES manufacturers, and Federal facility staff.

Chvala, William D.

2001-07-31T23:59:59.000Z

365

Southwestern Power Administration Annual Report 2011  

SciTech Connect (OSTI)

Dear Secretary Chu: I am pleased to present the financial statements and operating data for Southwestern Power Administration (Southwestern) for Fiscal Year (FY) 2011. In FY 2011, Southwestern delivered over 4.1 billion kilowatt-hours of energy to its wholesale customers in Arkansas, Kansas, Louisiana, Missouri, Oklahoma, and Texas, generating $167 million in revenue. In fulfilling its mission to market and reliably deliver renewable Federal hydroelectric power, Southwestern maintains 1,380 miles of high-voltage transmission lines, substations, and communications sites, contributing to the reliability of the regional and National electric grid. Southwestern also actively partners with the Department of Energy, the U.S. Army Corps of Engineers, Southwestern’s customers, and other Federal power stakeholders to most effectively balance their diverse interests with Southwestern’s mission while continuing to maximize Federal assets to repay the Federal investment in the 24 hydropower facilities within Southwestern’s marketing region. Southwestern is proud of its past successes, and we look forward to continuing to serve the Nation’s energy needs in the future. Sincerely, Christopher M. Turner Administrator

none,

2013-04-01T23:59:59.000Z

366

Southwestern Power Administration Annual Report 2010  

SciTech Connect (OSTI)

Dear Secretary Chu: I am pleased to present the financial statements and operating data for Southwestern Power Administration (Southwestern) for Fiscal Year (FY) 2010. In FY 2010, Southwestern delivered nearly 7.6 billion kilowatt-hours of energy to its wholesale customers in Arkansas, Kansas, Louisiana, Missouri, Texas, and Oklahoma, generating $189 million in revenue. In fulfilling its mission to market and reliably deliver renewable Federal hydroelectric power, Southwestern maintains 1,380 miles of high-voltage transmission lines, substations, and communications sites, contributing to the reliability of the regional and National electric grid. Southwestern also actively partners with the Department of Energy, the U.S. Army Corps of Engineers, Southwestern’s customers, and other Federal power stakeholders to most effectively balance their diverse interests with Southwestern’s mission while continuing to maximize Federal assets to repay the Federal investment in the 24 hydropower facilities within Southwestern’s marketing region. Southwestern is proud of its past successes, and we look forward to continuing to serve the Nation’s energy needs in the future. Sincerely, Christopher M. Turner Administrator

none,

2012-09-01T23:59:59.000Z

367

Southwestern Power Administration Annual Report 2012  

SciTech Connect (OSTI)

Dear Secretary Moniz: I am pleased to present the financial statements and operating data for Southwestern Power Administration (Southwestern) for Fiscal Year (FY) 2012. In FY 2012, Southwestern delivered over 4.1 billion kilowatt-hours of energy to its wholesale customers in Arkansas, Kansas, Louisiana, Missouri, Oklahoma, and Texas, generating $195 million in revenue. In fulfilling its mission to market and reliably deliver renewable Federal hydroelectric power, Southwestern maintains 1,380 miles of high-voltage transmission lines, substations, and communications sites, contributing to the reliability of the regional and National electric grid. Southwestern also actively partners with the Department of Energy, the U.S. Army Corps of Engineers, Southwestern’s customers, and other Federal power stakeholders to most effectively balance their diverse interests with Southwestern’s mission while continuing to maximize Federal assets to repay the Federal investment in the 24 hydropower facilities within Southwestern’s marketing region. Southwestern is proud of its past successes, and we look forward to continuing to serve the Nation’s energy needs in the future. Sincerely, Christopher M. Turner Administrator

none,

2013-09-01T23:59:59.000Z

368

C:\\Users\\mrognlie.MSU\\Desktop\\Acronyms.doc State and Federal Agricultural Acronyms  

E-Print Network [OSTI]

C:\\Users\\mrognlie.MSU\\Desktop\\Acronyms.doc State and Federal Agricultural Acronyms Miscellaneous Center #12;State and Federal Agricultural Acronyms Printed 12/23/2009 Page 2 EFAC ­ Equipment Fee LN ­ Linfield Hall LRBP ­ Long Range Building Program LRCDP ­ Long Range Campus Development Plan (or

Maxwell, Bruce D.

369

Contrail Virtual Execution Platform Challenges in Being Part of a Cloud Federation  

E-Print Network [OSTI]

Contrail Virtual Execution Platform Challenges in Being Part of a Cloud Federation Piyush Harsh will provide a federation layer support for bringing a multitude of cloud providers, both private and public, health care providers to name a few. This paper describes the novel features we are building

Paris-Sud XI, Université de

370

BOOSTING PRIVATE SECTOR COMPETITIVENESS THROUGH FEDERALLY-FUNDED WEATHER & ENVIRONMENTAL R&D  

E-Print Network [OSTI]

BOOSTING PRIVATE SECTOR COMPETITIVENESS THROUGH FEDERALLY-FUNDED WEATHER & ENVIRONMENTAL R&D LUNCHEON BRIEFING INVITATION Thursday, June 22 12:00 noon to 1:30 pm, Rayburn Building, Room 2325 In announcing the American Competitiveness Initiative (ACI), President Bush said: "Federal investment

371

45966 Federal Register / Vol. 52, No. 232 / Thursday, December 3, 1987 / Rules and Regulations INTERSTATE COMMERCE  

E-Print Network [OSTI]

with a separate expression. Noreta R. McGee, Secretary. Title 49 of the Code of Federal Regulations, Part 105245966 Federal Register / Vol. 52, No. 232 / Thursday, December 3, 1987 / Rules and Regulations Concepts, Inc., Room 2229, Interstate Commerce Commission Building, Washington, DC 20423, or call (202) 289

372

Project Title and Principal Investigators FY 2014 Federal  

E-Print Network [OSTI]

Sea Grant Program Project Title and Principal Investigators FY 2014 Federal Funding * FY 2014, NY, RI, WHOI Buy Out or Build Back? A Comparative Assessment of Approaches to Employing Public Stewards Academies in Maryland (Dana R. Fisher) $69,999 $35,007 MI Development of Stable Open Channel

373

Illinois Institute of Technology 3300 S. Federal St.  

E-Print Network [OSTI]

IIT Press Illinois Institute of Technology 3300 S. Federal St. Main Building 301 Chicago, IL 60616 Dissertation Printing Form Student's Signature Date Advisor's Signature Date Graduate College Approval Date r Dissertation to be printed exactly as approved by the thesis committee and the thesis defense examiner. r

Heller, Barbara

374

DIVISION OF ADMINISTRATION  

E-Print Network [OSTI]

, Oceanic & Atmospheric HSBC Health Sciences Business Center UABC University Administrative Employee

Escher, Christine

375

Appliance Standards and Rulemaking Federal Advisory Committee...  

Energy Savers [EERE]

of the National Energy Laboratories Buildings Home About Emerging Technologies Residential Buildings Commercial Buildings Appliance & Equipment Standards Building Energy Codes...

376

Building Stones  

E-Print Network [OSTI]

1992 Are the pyramids of Egypt built of poured concreteel-Anba’ut, Red Sea coast, Egypt. Marmora 6, pp. 45 - 56.building stones of ancient Egypt are those relatively soft,

2012-01-01T23:59:59.000Z

377

Building Science  

Broader source: Energy.gov [DOE]

This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question How do we first do no harm with high-r enclosures??

378

Building debris  

E-Print Network [OSTI]

This thesis relates architectural practices to intelligent use of resources and the reuse of derelict spaces. The initial investigation of rammed earth as a building material is followed by site-specific operations at the ...

Dahmen, Joseph (Joseph F. D.)

2006-01-01T23:59:59.000Z

379

Healthy buildings  

SciTech Connect (OSTI)

This book is covered under the following headings: Healthy building strategies/productivity, Energy and design issues, Ventilation, Contaminants, Thermal, airflow, and humidity issues, School-related issues, Sources and sinks, Filtering, Operation and maintenance.

Not Available

1991-01-01T23:59:59.000Z

380

Better Buildings  

E-Print Network [OSTI]

Challenge National leadership Initiative Better Information MOU with the Appraisal Foundation Better Tax Incentives/Credits New :179d eligibility and tool; Announced in March Better Financing With Small Business...: engaging in ESCO financing with low interest bonds) ?Tenant/Employee behaviors at odds with efficiency goals ?Split incentives ?Not enough/qualified workforce Better Buildings strategies to overcome barriers and drive action 4 Better Buildings...

Neukomm, M.

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Healthy buildings  

SciTech Connect (OSTI)

This proceedings is of the Indoor Air Quality (IAQ) Conference held September 4--8, 1991 in Washington, D.C. Entitled the IAQ 91, Healthy Buildings,'' the major topics of discussion included: healthy building strategies/productivity; energy and design issues; ventilation; contaminants; thermal, airflow, and humidity issues; school-related issues; sources and sinks; filtering; and operation and maintenance. For these conference proceedings, individual papers are processed separately for input into the Energy Data Base. (BN)

Geshwiler, M.; Montgomery, L.; Moran, M. (eds.)

1991-01-01T23:59:59.000Z

382

Archive Reference Buildings by Building Type: Warehouse  

Broader source: Energy.gov [DOE]

Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

383

Archive Reference Buildings by Building Type: Supermarket  

Broader source: Energy.gov [DOE]

Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

384

NREL: Technology Deployment - Other Federal Agency Support  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the Contributions andData and ResourcesOther Federal Agency Support Photo of a man and a

385

Federal Register Notice  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power SystemsResourcesFLASH2011-11-OPAMFY 2007 Total System12Federal Long Tern810 Federal Register

386

Building America Webinar: Ventilation in Multifamily Buildings...  

Energy Savers [EERE]

Residential Buildings (CARB), and discussed ventilation strategies for multifamily buildings, including how to successfully implement those strategies through smart design,...

387

Seminar on building codes and standards  

SciTech Connect (OSTI)

A seminar was conducted for state building code officials and state energy officials to discuss the following: status of the states regulatory activities for energy conservation standards for buildings; the development, administration, and enforcement processes for energy conservation standards affecting new construction; lighting and thermal standards for existing buildings; status of the development and implementation of the Title III Program, Building Energy Performance Standards (BEPS); and current status of the State Energy Conservation Program. The welcoming address was given by John Wenning and the keynote address was delivered by John Millhone. Four papers presented were: Building Energy Performance Standards Development, James Binkley; Lighting Standards in Existing Buildings, Dorothy Cronheim; Implementation of BEPS, Archie Twitchell; Sanctions for Building Energy Performance Standards, Sue Sicherman.

Not Available

1980-01-01T23:59:59.000Z

388

SOVIETS BUILD MACHINES TO PRODUCE KRILL PASTE'  

E-Print Network [OSTI]

EUROPE SOVIETS BUILD MACHINES TO PRODUCE KRILL PASTE' The Soviet Federal Research Institute of Fisheries and Oceanography ( V N I R 0) has built machines for production of a protein- rich paste from protein paste from Black Sea shrimp. Each machine, operated by 2 people, has a processing capacity of 1

389

Building Scale DC Microgrids  

E-Print Network [OSTI]

Efficiency and Renewable Energy, Building TechnologiesEfficiency and Renewable Energy, Building Technologies

Marnay, Chris

2013-01-01T23:59:59.000Z

390

Better Buildings Alliance  

Broader source: Energy.gov [DOE]

Commercial Buildings Integration Project for the 2013 Building Technologies Office's Program Peer Review

391

Federal Laboratory Technology Transfer  

E-Print Network [OSTI]

Federal Laboratory Technology Transfer Fiscal Year 2009 Prepared by: National Institute to submit this fiscal year 2009 Technology Transfer Summary Report to the President and the Congress in accordance with 15 USC Sec 3710(g)(2) for an annual summary on the implementation of technology transfer

Perkins, Richard A.

392

Federal Laboratory Technology Transfer  

E-Print Network [OSTI]

Federal Laboratory Technology Transfer Fiscal Year 2008 Prepared by: National Institute to submit this fiscal year 2008 Technology Transfer Summary Report to the President and the Congress transfer authorities established by the Technology Transfer Commercialization Act of 2000 (P.L. 106

Perkins, Richard A.

393

632 Appendix Federal Infonnation  

E-Print Network [OSTI]

632 Appendix Federal Infonnation Processing Standards Publication 46 1977 JanuW)' 15 ANNOUNCING. d.,~ !oh)' II. 1973). and P." 6 of Tit\\rCt·Rl. Name (If Standard with a key. The key is generated in such a way that each of the 56 bits used directly by the algori~hrn an' r

Holden, Joshua Brandon

394

da Reitoria UNIVERSIDADE FEDERAL  

E-Print Network [OSTI]

Aperfeiçoamento Institucional. A PRESIDENTE DO CONSELHO UNIVERSITÁRIO da Universidade Federal de Santa Catarina, mudando o nome da Secretaria Especial de Aperfeiçoamento Institucional para "Secretaria de Aperfeiçoamento) Secretaria de Relações Internacionais; c) Secretaria de Gestão de Pessoas; d) Secretaria de Aperfeiçoamento

Floeter, Sergio Ricardo

395

Federal Employee Training  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To plan and establish requirements and assign responsibilities for Department of Energy (DOE) Federal employee training, education, and development (hereafter referred to as "training") under the Government Employees Training Act of 1958. Cancels DOE O 360.1A. Canceled by DOE O 360.1C.

2001-10-11T23:59:59.000Z

396

Federal Employee Training  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To plan and establish requirements and assign responsibilities for Department of Energy (DOE) Federal employee training, education, and development under the Government Employees Training Act of 1958, as amended. Cancels DOE O 360.1. Canceled by DOE O 360.1B.

1999-09-21T23:59:59.000Z

397

Federal Employee Training  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Order establishes requirements and responsibilities for DOE Federal employee training in accordance with Chapter 41 of Title 5, United States Code (U.S.C.). Cancels DOE O 360.1B and DOE M 360.1-1B.

2011-07-06T23:59:59.000Z

398

Federal Technical Capability  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To define requirements and responsibilities for meeting the Department of Energy (DOE) commitment to recruiting, deploying, developing, and retaining a technically competent workforce that will accomplish DOE missions in a safe and efficient manner through the Federal Technical Capability Program (FTCP). Chg. 1 dated 9-20-11 Cancels DOE O 426.1. Cancels DOE P 426.1.

2009-11-19T23:59:59.000Z

399

Appendix C: Criteria Review and Approach Documents, National Nuclear Security Administration  

Broader source: Energy.gov [DOE]

A section of Appendix C to DOE G 226.1-2A "Federal Line Management Oversight of Department of Energy Nuclear Facilities." Consists of a table of National Nuclear Security Administration Criteria Review and Approach Documents (CRADS).

400

Meeting Federal Energy Security Requirements  

Broader source: Energy.gov [DOE]

Presentation—given at at the Fall 2012 Federal Utility Partnership Working Group (FUPWG) meeting—discusses the opportunity to increase the scope of federal-utility partnerships for meeting energy security requirements.

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Demonstration Assessment of Light-Emitting Diode (LED) Retrofit Lamps at the Lobby of the Bonneville Power Administration, Portland, OR  

SciTech Connect (OSTI)

This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in the lobby of the Bonneville Power Administration (BPA) headquarters building in Portland, Oregon. The project involved a simple retrofit of 32 track lights used to illuminate historical black-and-white photos and printed color posters from the 1930s and 1940s. BPA is a federal power marketing agency in the Northwestern United States, and selected this prominent location to demonstrate energy efficient light-emitting diode (LED) retrofit options that not only can reduce the electric bill for their customers but also provide attractive alternatives to conventional products, in this case accent lighting for BPA's historical artwork.

Miller, Naomi

2011-07-01T23:59:59.000Z

402

ASHRAE's New Performance Measurement Protocols for Commercial Buildings  

E-Print Network [OSTI]

Services Administration. 10 IEA is the International Energy Agency. ESL-IC-08-10-11 Proceedings of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 2 The resultant protocols are intended to provide... Building Operations, Berlin, Germany, October 20-22, 2008 3 Chapter 1: Energy (Authors: MacDonald, Haberl). In Chapter 1 the protocols for measuring the building?s energy useare presented. These protocols begin with acollection of facility information...

Haberl, J.; Davies, H.; Owens, B.; Hunn, B.

403

Fish and Wildlife Administrator  

Broader source: Energy.gov [DOE]

The incumbent in this position will serve as a Fish and Wildlife Administrator for BPAs Fish and Wildlife Division. The Fish and Wildlife Administrator is responsible for overseeing projects, and...

404

ADMINISTRATIVE UNIVERSITY POLICY  

E-Print Network [OSTI]

ADMINISTRATIVE UNIVERSITY POLICY FACULTY UNIVERSITY POLICY STUDENT UNIVERSITY POLICY Issue stakeholder list "Log-In" of Proposed University Policy with the University Compliance Committee (UCC) UCC identifies which track (i.e., Administrative, Faculty, or Student) the proposed University Policy

405

Division of Administration  

E-Print Network [OSTI]

Contracts & Procurement Don Green Controller Steven Yim Budget Planning & Administration Sarah Song Admin Operations Lieutenant Scot Willey Administration Lieutenant John Brockie Division Communication Editorial Communication Editorial Board looks forward to improving communication within and from the Division and welcomes

de Lijser, Peter

406

Daryl Schacher Administrative  

E-Print Network [OSTI]

Daryl Schacher Manager, Materials Management Lyn Jose Administrative Support Marion Eastman Administrative Assistant Michael Kern Shipper/Receiver Allan Besplug Materials Handling Worker Chris Charles Materials Handling Worker Gerry Ste Marie Materials Handling Worker Mark Sabo Materials Handling Worker

Hossain, Shahadat

407

Federal Utility Partnership Working Group  

Broader source: Energy.gov [DOE]

The Federal Utility Partnership Working Group (FUPWG) establishes partnerships and facilitates communications among Federal agencies, utilities, and energy service companies. The group develops strategies to implement cost-effective energy efficiency and water conservation projects through utility incentive programs at Federal sites.

408

Federal Presence in Newfoundland and  

E-Print Network [OSTI]

with the national levels Primary reliance on Statistics Canada data Objective: to inform the debate #12;II Employment Federal Government employment Overall Military Executives Federal Government Business Enterprises employment #12;Figure 7 Federal Government Employment Newfoundland and Labrador, 1981-2005 0 2

deYoung, Brad

409

School of Business Administration  

E-Print Network [OSTI]

/370 BA) 725-8003 Glen Pullen, Faculty/Staff Network Administrator 725-5748 Glen's pager 921-0660 Corey Tigner, Computer Lab Network Administrator 725-3724 Corey's cell phone 799-7341 SBA Help Line 725School of Business Administration Faculty Handbook #12;Message From the Dean Dear Colleague

410

Buildings GHG Mitigation Estimator Worksheet, Version 1  

Broader source: Energy.gov [DOE]

Xcel document describes Version 1 of the the Buildings GHG Mitigation Estimator tool. This tool assists federal agencies in estimating the greenhouse gas mitigation reduction from implementing energy efficiency measures across a portfolio of buildings. It is designed to be applied to groups of office buildings, for example, at a program level (regional or site) that can be summarized at the agency level. While the default savings and cost estimates apply to office buildings, users can define their own efficiency measures, costs, and savings estimates for inclusion in the portfolio assessment. More information on user-defined measures can be found in Step 2 of the buildings emission reduction guidance. The output of this tool is a prioritized set of activities that can help the agency to achieve its greenhouse gas reduction targets most cost-effectively.

411

Building Bridges: Federal Agencies Join Forces to Promote Sustainable...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

October 20, 2014 - 5:00pm Addthis Based on feedback received during the annual White House Tribal Nations Conference, President Obama established the White House Council...

412

2013 Better Building Federal Award Frequently Asked Questions  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

A. The winner is not based on gross energy reductions, nor is it based on the lowest energy intensity (Btugross square foot). The winner will be decided by the greatest...

413

Federal Building Energy Use Benchmarking Guidance, August 2014 Update |  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAX POLICIES ANDIndustrial HygieneEnergyLead-acidPrimusContinued72Agency

414

Smart Federal Partnerships Build Our Biofuels Future | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels DataCombinedDepartment of EnergyServices Services Office ofSmallSmart

415

Better Buildings Federal Award Winners | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative FuelsBSCmemo.pdf BSCmemo.pdf BSCmemo.pdf MoreEnergyNaturalDepartmentFeet

416

Public Meeting Transcript: Sustainable Design Standards for Federal Buildings  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Careerlumens_placard-green.epsEnergy1.pdfMarket37963 Vol. 79, No.and/or8-458-DEC. 17,U.S.

417

DOE Releases Federal Building Metering Guidance | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana. DOCUMENTSof Energy DOEDOEAVAILABLEDepartment ofHeld this

418

Private Companies, Federal Agencies and National Labs Join Better Buildings  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomen OwnedofDepartmentEnergy GeneralSandy made landfallThatBelow isChallenge to

419

Federal Buildings Supplemental Survey--Public Use Files  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia,(Million Barrels) Crude Oil Reserves in Nonproducing Reservoirs U.S.WyomingExpansion and Change on the

420

Energy Department Announces Winner of the 2013 Better Buildings Federal  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: TopEnergyIDIQBusiness Competition | Department of EnergyatBusinesses

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Energy Department Announces Winner of the 2013 Better Buildings Federal  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: TopEnergyIDIQBusiness Competition | Department of EnergyatBusinessesAward

422

CBECS 1993 - Federal Buildings Supplement Survey - Detailed Tables  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National and Regional Data; Row: NAICS98,,,1999,0,0,1e+15,1469,6,01179,"WAT","HY"Tables andA 6 J (MillionCubic35775 84Publication >

423

Buildings Energy Data Book: 7.2 Federal Tax Incentives  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.41466316167 Energy81

424

Buildings Energy Data Book: 7.2 Federal Tax Incentives  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.41466316167

425

Buildings Energy Data Book: 7.2 Federal Tax Incentives  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.414663161673 Tax

426

Buildings Energy Data Book: 7.2 Federal Tax Incentives  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.414663161673 Tax4

427

Buildings Energy Data Book: 7.2 Federal Tax Incentives  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.414663161673 Tax45

428

Buildings Energy Data Book: 7.2 Federal Tax Incentives  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.414663161673 Tax456

429

Buildings Energy Data Book: 7.2 Federal Tax Incentives  

Buildings Energy Data Book [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyAuthorization for(EV) Road UserNatural U.S.414663161673 Tax4567

430

Energy Intensity of Federal Buildings Slashed 25% in Past Decade |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPC ENABLE:2009 DOEDeploymentHenry C. FoleyEnergy FromCould

431

Better Building Federal Award Underway | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists' ResearchTheMarketing,Energy and NaturalBethel Valley Watershed. Topics include:

432

2013 Better Buildings Federal Award Winners | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergy Cooperation |South Valley Responsible DOEQA:Program PeerDepartment ofDepartmentProtection

433

Building Bridges: Federal Agencies Join Forces to Promote Sustainable,  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prev next

434

Report: President's Energy Efficiency Contracting for Federal Buildings a  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l L dDepartmentnews-flashesEnergy byNuclearof Energy Global

435

Energy Department Announces Winner of the 2013 Better Buildings Federal  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative FuelsBSCmemo.pdfAnnualAssessor-Award Competition | Department of Energy 3:51pm

436

Energy Department Announces Winner of the 2013 Better Buildings Federal  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative FuelsBSCmemo.pdfAnnualAssessor-Award Competition | Department of Energy

437

Using Dashboards to Improve Energy and Comfort in Federal Buildings  

E-Print Network [OSTI]

individual plug loads into the EIS for further analysis. Ourhow the performance of several EIS and dashboard case study4 Upgrading and Commissioning the EIS Hardware

Marini, Kyle

2011-01-01T23:59:59.000Z

438

Federal royalty oil eligibility requirements: the plateau legacy  

SciTech Connect (OSTI)

The courts ruled in the 1979 Plateau decision that the Secretary of the Interior is obligated to allocate federal royalty oil among all refineries not having their own crude oil source of supply, and can not impose Small Business Administration (SBA) eligibility requirements on potential purchasers of federal royalty oil. The effects of this decision was to derail the government's attempt to make royalty oil produced from Outer Continental Shelf leases and onshore sites available to the same refiners. The Minerals Management Service has yet to adopt final regulations harmonizing the court's ruling with applicable statutory requirements, resulting in actions of dubious legality. 75 references.

Zimmerman, J.J.; Bullerdick, K.H.

1984-01-01T23:59:59.000Z

439

Whole Building Cost and Performance Measurement: Data Collection Protocol Revision 2  

SciTech Connect (OSTI)

This protocol was written for the Department of Energy’s Federal Energy Management Program (FEMP) to be used by the public as a tool for assessing building cost and performance measurement. The primary audiences are sustainable design professionals, asset owners, building managers, and research professionals within the Federal sector. The protocol was developed based on the need for measured performance and cost data on sustainable design projects. Historically there has not been a significant driver in the public or private sector to quantify whole building performance in comparable terms. The deployment of sustainable design into the building sector has initiated many questions on the performance and operational cost of these buildings.

Fowler, Kimberly M.; Spees, Kathleen L.; Kora, Angela R.; Rauch, Emily M.; Hathaway, John E.; Solana, Amy E.

2009-03-27T23:59:59.000Z

440

An in-depth Analysis of Space Heating Energy Use in Office Buildings  

E-Print Network [OSTI]

. In this study, the prototypical small and large-size office buildings of the USDOE commercial reference is further benchmarked against those from similar office buildings in two U.S. commercial buildings databases is the largest one [USDOE]. The U.S. Energy Information Administration [EIA] 2003 Commercial Building Energy

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Executive Order 13423- Strengthening Federal Environmental, Energy...  

Energy Savers [EERE]

423- Strengthening Federal Environmental, Energy, and Transportation Management Executive Order 13423- Strengthening Federal Environmental, Energy, and Transportation Management It...

442

Federal Biomass Activities | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Federal Biomass Activities Federal Biomass Activities Statutory and executive order requirements for Bioproducts and Biofuels federalbiomassactivities.pdf More Documents &...

443

1995 Federal Research and Development Program in Materials Science and Technology  

SciTech Connect (OSTI)

The Nation's economic prosperity and military security depend heavily on development and commercialization of advanced materials. Materials are a key facet of many technologies, providing the key ingredient for entire industries and tens of millions of jobs. With foreign competition in many areas of technology growing, improvements in materials and associated processes are needed now more than ever, both to create the new products and jobs of the future and to ensure that U.S. industry and military forces can compete and win in the international arena. The Federal Government has invested in materials research and development (R&D) for nearly a century, helping to lay the foundation for many of the best commercial products and military components used today. But while the United States has led the world in the science and development of advanced materials, it often has lagged in commercializing them. This long-standing hurdle must be overcome now if the nation is to maintain its leadership in materials R&D and the many technologies that depend on it. The Administration therefore seeks to foster commercialization of state-of-the-art materials for both commercial and military use, as a means of promoting US industrial competitiveness as well as the procurement of advanced military and space systems and other products at affordable costs. The Federal R&D effort in Fiscal Year 1994 for materials science and technology is an estimated $2123.7 million. It includes the ongoing R&D base that support the missions of nine Federal departments and agencies, increased strategic investment to overcome obstacles to commercialization of advanced materials technologies, interagency cooperation in R&D areas of mutual benefit to leverage assets and eliminate duplicative work, cost-shared research with industrial and academic partners in critical precompetitive technology areas, and international cooperation on selected R&D topics with assured benefits for the United States. The materials R&D program also supports the Administration's specific technological objectives, emphasizing development of affordable, high-performance commercial and military aircraft; ultra-fuel-efficient, low-emissions automobiles that are also safe and comfortable; powerful yet inexpensive electronic systems; environmentally safe products and processes; and a durable building and transportation infrastructure.

None

1995-12-01T23:59:59.000Z

444

Building Performance Simulation  

E-Print Network [OSTI]

technologies, integrated design, building operation andperformance,  integrated  building design and operation, Integrated  Design  and  Operation  for  Very  Low  Energy  Buildings

Hong, Tianzhen

2014-01-01T23:59:59.000Z

445

Buildings Energy Program annual report, FY 1991  

SciTech Connect (OSTI)

The Buildings Energy Program at PNL conducts research and development (R&D) for DOE`s Office of Building Technologies (OBT). The OBT`s mission is to lead a national program supporting private and federal sector efforts to improve the energy efficiency of the nation`s buildings and to increase the use of renewable energy sources. Under an arrangement with DOE, Battelle staff also conduct research and development projects for other federal agencies and private clients. This annual report contains an account of the buildings-related research projects conducted at PNL during fiscal year (FY) 1991. A major focus of PNL`s energy projects is to improve the energy efficiency of commercial and residential buildings. Researchers who are developing solutions to energy-use problems view a building as an energy-using system. From this perspective, a desirable solution is not only one that is cost-effective and responsive to the needs of the occupants, but also one that optimizes the interaction among the energy components and systems that compose the whole.

Secrest, T.J.

1992-05-01T23:59:59.000Z

446

Southeastern Power Administration | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Southeastern Power Administration Southeastern Power Administration Southeastern Power Administration View All Maps Addthis...

447

Annual report to Congress on Federal Government Energy Management and Conservation Programs  

SciTech Connect (OSTI)

This report on Federal Energy Management for Fiscal year (FY) 1992 provides information on energy consumption in Federal buildings and operations and documents activities conducted by Federal agencies to meet the statutory requirements of Title V, Part 3, of the National Energy Conservation Policy Act (NECPA), as amended, 42 U.S.C. 8251-8261, and Title VIII of NECPA, 42 U.S.C. 8287-8287b. This report also describes the energy conservation and management activities of the Federal Government under the authorization of section 381 of the Energy Policy and Conservation Act (EPCA), as amended, 42 U.S.C. 6361. Implementation activities undertaken during FY 1992 by the Federal agencies under Executive Order 12759 on Federal Energy Management are also described in this report.

Not Available

1994-02-01T23:59:59.000Z

448

The Role of Incentives in Building Controls Marketplace  

E-Print Network [OSTI]

that innovative solutions can reduce energy consumption by 25 to 40 percent. According to the Energy Information Administration, buildings today consume 42 percent of energy generated, making investing in energy efficiency a critical piece of efforts to reduce...

Vanderpool, C.

2011-01-01T23:59:59.000Z

449

The energy behind the power. Southwestern Power Administration 1994 annual report  

SciTech Connect (OSTI)

This is the Southwestern Power Administration 1994 annual report. The topics of the report include a letter to the secretary; an overview including the mission statement, a description of the Southwestern Federal Power System, financial statement, performance measurements, national performance review; year in review, summary of results, financial and statistical data and the Southwestern Power Administration Organization.

NONE

1994-12-31T23:59:59.000Z

450

Executive Order 12699 - Seismic Safety of Federal and Federally Assisted or Regulated New Building Construction  

National Nuclear Security Administration (NNSA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartmentNationalRestart of the Review of theOFFICEACME |Supplement5869Google EarthUSE

451

Direct Federal Financial  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation Proposed Newcatalyst phasesData FilesShape,PhysicsDileepDiracNanotubes . |Federal

452

Federal Financial Report  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines AboutDecemberSteam Coal Import96Nebraska NuclearDecade2003 DetailedUsebaseline 12FEDERAL

453

WIPP Documents - Federal Regulations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert SouthwestTechnologies | Blandine Jerome VelenciaNewsNewsFederal Regulations 40 CFR

454

U.S.U.S. Federal Agency Purchasing ManagersFederal Agency Purchasing Managers Fuel Cell Systems for Portable, Backup and UPSFuel Cell Systems for Portable, Backup and UPS  

E-Print Network [OSTI]

U.S.U.S. Federal Agency Purchasing ManagersFederal Agency Purchasing Managers Fuel Cell Systems, remote, aux. power Buildings & Facilities · 100 Kilowatts to · Primary power, critica Speciality vehicles applications world-wide. Central Oregon business, 68 Employees World class energy technology company focused

455

Coordination of Federal Transmission Permitting on Federal Lands...  

Office of Environmental Management (EM)

transmission facilities on federal lands. In most instances, the Departments of Agriculture or Interior will be the Lead Agency, since they have jurisdiction over most of the...

456

Southeastern Power Administration 2007 Annual Report  

SciTech Connect (OSTI)

Dear Secretary Chu: I am proud to submit Southeastern Power Administration’s (Southeastern’s) fiscal year (FY) 2007 Annual Report for your review. The information included in this report reflects Southeastern’s programs, accomplishments, and financial activities for the 12-month period beginning October 1, 2006 and ending September 30, 2007. Southeastern marketed more than 5 billion kilowatt-hours of energy to 492 wholesale Federal power customers in an 11-state marketing area in FY 2007. Revenues from the sale of this power totaled approximately $219 million. Drought conditions continued to plague the southeast region of the United States during 2007 placing strains on our natural and financial resources. Southeastern purchased more than $40 million in replacement power to meet customer contract requirements to ensure the continued reliability of our nation’s power grid. With the financial assistance and support of our Federal power customers, continued funding for capitalized equipment replacements at various Corps of Engineers’ (Corps) hydroelectric projects provided much needed repairs and maintenance for aging facilities. Southeastern’s cyber and physical security program continued to be reviewed and updated to meet Department of Energy (DOE), Homeland Security, and North American Electric Reliability Corporation standards and requirements. Plans for the upcoming year include communication and cooperation with DOE, Federal power customers, and the Corps to maximize the benefits of our nation’s water resources. Competition for the use of water and the prolonged drought conditions will present another challenging year for our agency. The employees at Southeastern will be proactive in meeting these challenges and providing reliable hydroelectric power to the people in the southeast. Sincerely, Kenneth E. Legg Administrator

none,

2007-12-28T23:59:59.000Z

457

67425Federal Register / Vol. 79, No. 219 / Thursday, November 13, 2014 / Notices effective on the date of publication of  

E-Print Network [OSTI]

67425Federal Register / Vol. 79, No. 219 / Thursday, November 13, 2014 / Notices effective on the date of publication of the ITC's notice of final determination in the Federal Register, and to require contact the Department's Central Records Unit, Room 7046 of the main Commerce Building, for copies

458

Tenant Guidelines National Park Service and the U.S. Department of Energy, Federal Energy Management Program  

E-Print Network [OSTI]

Tenant Guidelines National Park Service and the U.S. Department of Energy, Federal Energy Management Program for Energy-Efficient Renovation of Buildings at the Presidio of San Francisco #12 like to thank the following reviewers for their comments: Anne Sprunt Crawley, Federal Energy

Diamond, Richard

459

National Nuclear Security Administration  

Broader source: Energy.gov (indexed) [DOE]

and Related Structures within TA-3 at Los Alamos National Laboratory, Los Alamos, New Mexico U. S. Department of Energy National Nuclear Security Administration Los Alamos Area...

460

November 2009 | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartmentNationalRestart of the Review of the Yucca0AdministrationNext100 Federal09 |

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

THE CONTENT OF CORPORATE FEDERALISM  

E-Print Network [OSTI]

Federalism in Corporate Governance: Protecting ShareholderCollaborative Corporate Governance: Listing Standards, Stateof Care Stadanrd in Corporate Governance 75 Iowa L. Rev. 1,

Bratton, William W.

2004-01-01T23:59:59.000Z

462

3Building a Business Building a Business  

E-Print Network [OSTI]

15 3Building a Business Building a Business This section provides direction on the kinds. If you contemplate building a "garage- based" company to sell a product into a niche market, you should-ups conjure up images of future wealth, of building the next Amgen or Microsoft, of launching what will become

Arnold, Jonathan

463

Office of Administration  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

Designated to be responsible for developing, implementing, and maintaining an Occupant Emergency Plan, as required by 41 CFR 101-20.103-4, for all Department's Headquarters Buildings.

2002-04-30T23:59:59.000Z

464

The Global Threat Reduction Initiative's Orphan Source Recovery Project in the Russian Federation  

SciTech Connect (OSTI)

After 9/11, officials at the United States Department of Energy (DOE), National Nuclear Security Administration (NNSA) grew more concerned about radiological materials that were vulnerable to theft and illicit use around the world. The concern was that terrorists could combine stolen radiological materials with explosives to build and detonate a radiological dispersal device (RDD), more commonly known as a “dirty bomb.” In response to this and other terrorist threats, the DOE/NNSA formed what is now known as the Global Threat Reduction Initiative (GTRI) to consolidate and accelerate efforts to reduce and protect vulnerable nuclear and radiological materials located at civilian sites worldwide. Although a cooperative program was already underway in the Russian Federation to secure nuclear materials at a range of different facilities, thousands of sealed radioactive sources remained vulnerable at medical, research, and industrial sites. In response, GTRI began to focus efforts on addressing these materials. GTRI’s Russia Orphan Source Recovery Project, managed at the Nevada National Security Site’s North Las Vegas facility, was initiated in 2002. Throughout the life of the project, Joint Stock Company “Isotope” has served as the primary Russian subcontractor, and the organization has proven to be a successful partner. Since the first orphan source recovery of an industrial cobalt-60 irradiator with 647 curies (Ci) at an abandoned facility in Moscow in 2003, the GTRI Orphan Source Recovery Project in the Russian Federation has accomplished substantial levels of threat reduction. To date, GTRI has recovered and securely disposed of more than 5,100 sources totaling more that 628,000 Ci. This project serves as an extraordinary example of how international cooperation can be implemented by partners with mutual interests to achieve significant goals.

Russell, J. W. [NSTec; Ahumada, A. D. [NSTec; Blanchard, T. A. [NNSA

2012-06-04T23:59:59.000Z

465

Building America Building Science Translator  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd: ScopeDepartment1,Energy ForBryanR BUILDING AMERICA

466

ADMINISTRATION CONTRACT NO.  

E-Print Network [OSTI]

MANAGEMENT AND OPERATING CONTRACT FOR THE LOS ALAMOS NATIONAL LABORATORY NATIONAL NUCLEAR SECURITY ADMINISTRATION CONTRACT NO. DE-AC52-06NA25396 DECEMBER 21, 2005 1943 Today Unofficial Conformed Copy as of 1 OF ENERGY NATIONAL NUCLEAR SECURITY ADMINISTRATION NNSA SERVICE CENTER- ALBUQUERQUE M&O CONTRACT SUPPORT

467

Introduction Business Administration  

E-Print Network [OSTI]

spectacularly in Japan after Osaka University of Commerce was established as the third Higher Commercial School. The School of Business Administration, Kobe University has developed into a leading institution of business administration, accounting, and commercial science, and has been leading these areas of research and education

Banbara, Mutsunori

468

Guiding Principles for Sustainable Existing Buildings: Radiochemical Processing Laboratory  

SciTech Connect (OSTI)

In 2006, the United States (U.S.) Department of Energy (DOE) signed the Federal Leadership in High Performance and Sustainable Buildings Memorandum of Understanding (MOU), along with 21 other agencies. Pacific Northwest National Laboratory (PNNL) is exceeding this requirement and, currently, about 25 percent of its buildings are High Performance and Sustainable Buildings. The pages that follow document the Guiding Principles conformance effort for the Radiochemical Processing Laboratory (RPL) at PNNL. The RPL effort is part of continued progress toward a building inventory that is 100 percent compliant with the Guiding Principles.

Pope, Jason E.

2013-11-11T23:59:59.000Z

469

Smart Buildings: Business Case and Action Plan  

SciTech Connect (OSTI)

General Services Administration (GSA) has been a pioneer in using Smart Building technologies but it has yet to achieve the full benefits of an integrated, enterprise-wide Smart Building strategy. In July 2008, GSA developed an initial briefing memorandum that identified five actions for a Smart Buildings feasibility study: (1) Identify and cluster the major building systems under consideration for a Smart Buildings initiative; (2) Identify GSA priorities for these clusters; (3) Plan for future adoption of Smart Building strategies by identifying compatible hardware; (4) Develop a framework for implementing and testing Smart Building strategies and converged networks; and (5) Document relevant GSA and industry initiatives in this arena. Based on this briefing memorandum, PBS and FAS retained consultants from Lawrence Berkeley National Laboratory, Noblis, and the Building Intelligence Group to evaluate the potential for Smart Buildings within GSA, and to develop this report. The project has included extensive interviews with GSA staff (See Appendix A), a review of existing GSA standards and documents, and an examination of relevant GSA and industry initiatives. Based on interviews with GSA staff and a review of GSA standards and documents, the project team focused on four goals for evaluating how Smart Building technology can benefit GSA: (1) Achieve Energy Efficiency Mandates--Use Smart Building technology as a tool to meet EISA 2007 and EO 13423 goals for energy efficiency. (2) Enhance Property Management--Deploy enterprise tools for improved Operations and Maintenance (O&M) performance and verification. (3) Implement Network as the Fourth Utility--Utilize a converged broadband network to support Smart Building systems and provide GSA clients with connectivity for voice, data and video. (4) Enhance Safety and Security--Harmonize Physical Access Control Systems (PACS) with Smart Building Systems.

Ehrlich, Paul; Diamond, Rick

2009-04-01T23:59:59.000Z

470

BREAKING WITH OR BUILDING ON THE PAST? REFORMING IRISH PUBLIC  

E-Print Network [OSTI]

of the application of new public management styles to Ireland. Particular attention is paid to the public serviceBREAKING WITH OR BUILDING ON THE PAST? REFORMING IRISH PUBLIC ADMINISTRATION: 1958-2008 Niamh? REFORMING IRISH PUBLIC ADMINISTRATION: 1958-2008 Niamh Hardiman and Muiris MacCarthaigh Working Papers

471

Building Technologies Office | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power Systems EngineeringDepartment of4 Federal6Clean Energy |-FormerofBuilding RemovalBuilding

472

Building and Buildings, Scotland: Draft Building Standards (Scotland) Regulations, 1961   

E-Print Network [OSTI]

These regulations, made under the Building (Scotland) Act, 1959, prescribe standards for buildings for the purposes of Part II of that Act. The matters in relation to which standards have been prescribed are described in ...

Her Majesty's Stationary Office

1961-01-01T23:59:59.000Z

473

Gauging Improvements in Urban Building Energy Policy in India  

E-Print Network [OSTI]

development of training for local level administrators, especially inspectors, and the development of curriculum to train construction professionals in building energyEnergy Conservation in Buildings Code (ECBC), remains voluntary throughout most of India while local-level agencies work towards implementation capacity development.

Williams, Christopher

2013-01-01T23:59:59.000Z

474

RECOMMENDED SECURITY CONTROLS FOR FEDERAL  

E-Print Network [OSTI]

May 2005 RECOMMENDED SECURITY CONTROLS FOR FEDERAL INFORMATION SYSTEMS: GUIDANCE FOR SELECTING COST-EFFECTIVE CONTROLS USING A RISK-BASED PROCESS Shirley Radack, Editor, Computer Security Division, Information-53, Recommended Security Controls for Federal Information Systems The basic questions that organizations should

475

The State Energy Program: Building Energy Efficiency and Renewable Energy Capacity in the States  

Broader source: Energy.gov [DOE]

This study documents the capacity-building effects that the federal State Energy Program (SEP) has had on the states' capacity to design, manage and implement energy efficiency and renewable energy programs.

476

New and Existing Buildings Heating and Cooling Opportunities: Dedicated Heat Recovery Chiller  

Broader source: Energy.gov [DOE]

Presentation covers the new and existing buildings heating and cooling opportunities and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

477

Building Technologies Program: Tax Deduction Qualified Software- DOE-2.2 version 47d  

Broader source: Energy.gov [DOE]

On this page you'll find information about the DOE-2.2 version 47d qualified computer software, which calculates energy and power cost savings that meet federal tax incentive requirements for commercial buildings.

478

Help Build a Better Energy Information Administration Website...  

Broader source: Energy.gov (indexed) [DOE]

Both the novice and expert can create graphics showing energy trends in petroleum, natural gas and electricity data, such as: Comparing one state's current gasoline prices with...

479

Obama Administration Launches $130 Million Building Energy Efficiency...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Announces 20 Million for 10 Public-Private Partnerships to Support American Manufacturing and Encourage Investment in the U.S. Obama Adminstration Announces Launch of...

480

Graduate Council Meeting Agenda 310 Jack K. Williams Administration Building  

E-Print Network [OSTI]

Nuclear Terrorism Threat Assessment and Analysis l. INTA 672 East Asian Security (tabled in March 2013) m 645 IT Security Controls e. ISYS 655 Security Management and Compliance f. PSAA 613 Immigration. INTA 672 East Asian Security j. INTA 673 Chinese Domestic Politics in Transition k. INTA 674 US Foreign

Note: This page contains sample records for the topic "administration federal buildings" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

The Bonneville Power Administration is proposing to build a 500...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Our new map shows the updated preferred alternative based on changes we have made after working with landowners and other interested parties. Zoom in to the areas of interest to...

482

Graduate Council Meeting Minutes 310 Jack K. Williams Administration Building  

E-Print Network [OSTI]

Modeling and Analysis d. ISYS 645 IT Security Controls e. ISYS 655 Security Management and Compliance f... i. WFSC 605 Community Ecology j. WFSC 649 Principles of Fisheries Management The following new in Transition k. INTA 674 US Foreign Policy in the Persian Gulf l. INTA 675 Religion and Politics in Iran m

483

Obama Administration Expands Better Buildings Challenge to Multifamily  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAXBalanced ScorecardReactor TechnologyOFFICE: I Oak Ridge,8 8 8 , , ,theandHousing,

484

Energy Information Administration (EIA)- About the Commercial Buildings  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines AboutDecember 2005 (Thousand9,0, 1997Environment >7, 199930, 20005,6, 20003,

485

Energy Information Administration (EIA)- Guide to 2012 Commercial Buildings  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines AboutDecember 2005 (Thousand9,0, 1997Environment >7, 199930,Consumption

486

Obama Administration Announces 14 Initial Partners in the Better Buildings  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in3.pdfEnergyDepartment of Energy(National1 -OSS 19.3 ConfinedU.S. Small

487

Obama Administration Expands Better Buildings Challenge to Multifamily  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in3.pdfEnergyDepartment of Energy(National1 -OSSGas and OilinPrograms in

488

Obama Administration Launches $130 Million Building Energy Efficiency  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in3.pdfEnergyDepartment of Energy(National1 -OSSGas and OilinPrograms inwith

489

Obama Administration Announces New Partners Join the Better Buildings  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomen OwnedofDepartment ofJaredOakscience-based,OHA

490

Energy Information Administration (EIA)- About the Commercial Buildings  

Gasoline and Diesel Fuel Update (EIA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"Click worksheet9,1,50022,3,,,,6,1,,781 2,328 2,683Diesel pricesArkansas56,4/15/2015

491

BUILDING EFFECTIVENESS COMMUNICATION RATIOS FOR IMPROVED BUILDING LIFE CYCLE MANAGEMENT  

E-Print Network [OSTI]

BUILDING EFFECTIVENESS COMMUNICATION RATIOS FOR IMPROVED BUILDING LIFE CYCLE MANAGEMENT Elmer building energy performance assessment frameworks, quantifying and categorising buildings post occupancy a performance-based strategy utilising building effectiveness communication ratios stored in Building

492

History of the Energy Research and Development Administration  

SciTech Connect (OSTI)

Congress created the Energy Research and Development Administration on October 11, 1974 in response to the Nation's growing need for additional sources of energy. The new agency would coordinate energy programs formerly scattered among many federal agencies, and serve as the focus point for a major effort by the Federal Government to expand energy research and development efforts. New ways to conserve existing supplies as well as the commercial demonstration of new technologies would hopefully be the fruit of the Government's first significant effort to amalgamate energy resource development programs. This history briefly summarizes the accomplishments of the agency.

Buck, A.L.

1982-03-01T23:59:59.000Z

493

2013 Federal Energy and Water Management Award Winners | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

3 Federal Energy and Water Management Award Winners 2013 Federal Energy and Water Management Award Winners 2013 Federal Energy and Water Management Award Winners The Federal Energy...

494

Academic Buildings Student & Admin.  

E-Print Network [OSTI]

Academic Buildings Student & Admin. Services Residence Public Parking Permit Parking GatheringCampusRoad Shrum Science Centre South Sciences Building Technology & Science Complex 2 Greenhouses Science Research AnnexBee Research BuildingAlcan Aquatic Research Technology & Science Complex 1 C Building B Building P

495

and Pollutant Safeguarding Buildings  

E-Print Network [OSTI]

commercial buildings, these flows are driven primarily by the building's ventilation system, but natural2004 Airflow and Pollutant Transport Group Safeguarding Buildings Against Chemical and Biological research since 1998 to protect buildings and building occupants from threats posed by airborne chemical

496

Reliability and the Federal Energy Regulatory Commission  

Broader source: Energy.gov [DOE]

Presentation—given at the Federal Utility Partnership Working Group (FUPWG) Fall 2008 meeting—covers the Federal Energy Regulatory Commission (FERC) strategic plan, the Federal Power Act (FPA), current energy security posture, and more.

497

Federal Utility Program Overview (Fact Sheet)  

SciTech Connect (OSTI)

Fact sheet overview of the U.S. Department of Energy (DOE) Federal Energy Management Program's (FEMP) Federal Utility Program, including common contracts and services available to Federal agencies through local serving utilities.

Not Available

2009-07-01T23:59:59.000Z

498

Federal Greenhouse Gas Inventories and Performance  

Broader source: Energy.gov [DOE]

The Federal Energy Management Program provides performance data illustrating federal agency progress in meeting the greenhouse gas reduction targets established under Executive Order (E.O.) 13514, as well as the comprehensive greenhouse gas inventories as reported by federal agencies.

499

The Evolution of the Federal Monitoring and Assessment Center  

SciTech Connect (OSTI)

The Federal Radiological Monitoring and Assessment Center (FRMAC) is a federal emergency response asset whose assistance may be requested by the Department of Homeland Security (DHS), the Department of Defense (DoD), the Environmental Protection Agency (EPA), the Nuclear Regulatory Commission (NRC), and state and local agencies to respond to a nuclear or radiological incident. It is an interagency organization with representation from the Department of Energy’s National Nuclear Security Administration (DOE/NNSA), the Department of Defense (DoD), the Environmental Protection Agency (EPA), the Department of Health and Human Services (HHS), the Federal Bureau of Investigation (FBI), and other federal agencies. FRMAC, in its present form, was created in 1987 when the radiological support mission was assigned to the DOE’s Nevada Operations Office by DOE Headquarters. The FRMAC asset, including its predecessor entities, was created, grew, and evolved to function as a response to radiological incidents. Radiological emergency response exercises showed the need for a coordinated approach to managing federal emergency monitoring and assessment activities. The mission of FRMAC is to coordinate and manage all federal radiological environmental monitoring and assessment activities during a nuclear or radiological incident within the United States in support of state,local, tribal governments, DHS, and the federal coordinating agency. Radiological emergency response professionals with the DOE’s national laboratories support the Radiological Assistance Program (RAP), National Atmospheric Release Advisory Center (NARAC), the Aerial MeasuringSystem (AMS), and the Radiation Emergency Assistance Center/Training Site (REAC/TS). These teams support the FRMAC to provide: ? Atmospheric transport modeling ? Radiation monitoring ? Radiological analysis and data assessments ? Medical advice for radiation injuries In support of field operations, the FRMAC provides geographic information systems, communications, mechanical, electrical, logistics, and administrative support. The size of the FRMAC is tailored to the incident and is comprised of emergency response professionals drawn from across the federal government. State and local emergency response teams may also integrate their operations with FRMAC, but are not required to.

NSTec Aerial Measurement System

2012-07-31T23:59:59.000Z

500

Wynkoop Building Performance Measurement: Water  

SciTech Connect (OSTI)

This report is a summary of the water analysis performance for the Denver, Colorado Wynkoop Building. The Wynkoop Building (Figure 1) was built in 2006 as the Environmental Protection Agency (EPA) Region 8 Headquarters intended to house over 900 occupants in the 301,292 gross square feet (248,849 rentable square feet). The building was built on a brownfield in the Lower Downtown Historic District as part of an urban redevelopment effort. The building was designed and constructed through a public-private partnership with the sustainable design elements developed jointly by General Services Administration (GSA) and EPA. That partnership is still active with all parties still engaged to optimize building operations and use the building as a Learning Laboratory. The building design achieved U.S. Green Building Council Leadership in Energy and Environmental Design for New Construction (LEED-NC) Gold Certification in 2008 (Figure 2) and a 2008 EPA Energy Star Rating of 96 with design highlights that include: (1) Water use was designed to use 40% less than a typical design baseline. The design included low flow fixtures, waterless urinals and dual flush toilets; (2) Native and adaptive vegetation were selected to minimize the need for irrigation water for landscaping; and (3) Energy use intensity was modeled at 66.1 kBtus/gross square foot, which is 39% better than ASHRAE 90.1 1999. The Wynkoop Building water use (10 gallons/square foot) was measured at lower than industry average (15 gallons/square foot) and GSA goals (13 gallons/square foot), however, it was higher than building management expected it would be. The type of occupants and number of occupants can have a significant impact on fixture water use. The occupancy per floor varied significantly over the study time period, which added uncertainty to the data analysis. Investigation of the fixture use on the 2nd, 5th, and 7th floors identified potential for water use reduction if the flush direction of the dual-flush toilet handles was reversed. The building management retrofitted the building's toilets with handles that operated on reduced flush when pushed down (0.8 gallons) and full flush when pulled up (1.1 gallons). The water pressure on the 5th floor (< 30 psi) is less than half the pressure on the 7th floor (>80 psi). The measured water savings post-retrofit was lower on the 5th floor than the 7th floor. The differences in water pressure may have had an impact on the quantity of water used per floor. The second floor water use was examined prior to and following the toilet fixture retrofit. This floor is where conference rooms for non-building occupants are available for use, thus occupancy is highly variable. The 3-day average volume per flush event was higher post-retrofit (0.79 gallons per event), in contrast to pre-retrofit (0.57 gallons per event). There were 40% more flush events post retrofit, which impacted the findings. Water use in the third floor fitness center was also measured for a limited number of days. Because of water line accessibility, only water use on the men's side of the fitness center was measured and from that the total fitness center water use was estimated. Using the limited data collected, the fitness center shower water use is approximately 2% of the whole building water use. Overall water use in the Wynkoop Building is below the industry baseline and GSA expectations. The dual flush fixture replacement appears to have resulted in additional water savings that are expected to show a savings in the total annual water use.

Fowler, Kimberly M.; Kora, Angela R.

2012-08-26T23:59:59.000Z