National Library of Energy BETA

Sample records for actual actual actual

  1. How People Actually Use Thermostats

    SciTech Connect (OSTI)

    Meier, Alan; Aragon, Cecilia; Hurwitz, Becky; Mujumdar, Dhawal; Peffer, Therese; Perry, Daniel; Pritoni, Marco

    2010-08-15

    Residential thermostats have been a key element in controlling heating and cooling systems for over sixty years. However, today's modern programmable thermostats (PTs) are complicated and difficult for users to understand, leading to errors in operation and wasted energy. Four separate tests of usability were conducted in preparation for a larger study. These tests included personal interviews, an on-line survey, photographing actual thermostat settings, and measurements of ability to accomplish four tasks related to effective use of a PT. The interviews revealed that many occupants used the PT as an on-off switch and most demonstrated little knowledge of how to operate it. The on-line survey found that 89% of the respondents rarely or never used the PT to set a weekday or weekend program. The photographic survey (in low income homes) found that only 30% of the PTs were actually programmed. In the usability test, we found that we could quantify the difference in usability of two PTs as measured in time to accomplish tasks. Users accomplished the tasks in consistently shorter times with the touchscreen unit than with buttons. None of these studies are representative of the entire population of users but, together, they illustrate the importance of improving user interfaces in PTs.

  2. Could Material Defects Actually Improve Solar Cells?

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Could Material Defects Actually Improve Solar Cells? Could Material Defects Actually Improve Solar Cells? March 21, 2016 Contact: Kathy Kincade, kkincade@lbl.gov, +1 510 495 2124 NRELsolarcell Scientists at the U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) are using supercomputers to study what may seem paradoxical: certain defects in silicon solar cells may actually improve their performance. The findings, published January 11, 2016 in Applied Physics Letters,

  3. FY 2013 Real Property Deferred, Actual, and Required Maintenance...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real Property Deferred, Actual, and Required Maintenance Reporting Requirement FY 2013 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement PDF icon FY ...

  4. FY 2012 Real Property Deferred, Actual, and Required Maintenance...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Real Property Deferred, Actual, and Required Maintenance Reporting Requirement FY 2012 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement PDF icon FY ...

  5. Table 13. Coal Production, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Coal Production, Projected vs. Actual" "Projected" " (million short tons)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",999,1021,1041,1051,1056,1066,1073,1081,1087,1098,1107,1122,1121,1128,1143,1173,1201,1223 "AEO 1995",,1006,1010,1011,1016,1017,1021,1027,1033,1040,1051,1066,1076,1083,1090,1108,1122,1137 "AEO

  6. Table 22. Energy Intensity, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Energy Intensity, Projected vs. Actual" "Projected" " (quadrillion Btu / $Billion 2005 Chained GDP)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",10.89145253,10.73335719,10.63428655,10.48440125,10.33479508,10.20669515,10.06546105,9.94541493,9.822393757,9.707148466,9.595465524,9.499032573,9.390723436,9.29474735,9.185496812,9.096176848,9.007677565,8.928276581 "AEO

  7. Caustic-Side Solvent Extraction: Prediction of Cesium Extraction for Actual Wastes and Actual Waste Simulants

    SciTech Connect (OSTI)

    Delmau, L.H.; Haverlock, T.J.; Sloop, F.V., Jr.; Moyer, B.A.

    2003-02-01

    This report presents the work that followed the CSSX model development completed in FY2002. The developed cesium and potassium extraction model was based on extraction data obtained from simple aqueous media. It was tested to ensure the validity of the prediction for the cesium extraction from actual waste. Compositions of the actual tank waste were obtained from the Savannah River Site personnel and were used to prepare defined simulants and to predict cesium distribution ratios using the model. It was therefore possible to compare the cesium distribution ratios obtained from the actual waste, the simulant, and the predicted values. It was determined that the predicted values agree with the measured values for the simulants. Predicted values also agreed, with three exceptions, with measured values for the tank wastes. Discrepancies were attributed in part to the uncertainty in the cation/anion balance in the actual waste composition, but likely more so to the uncertainty in the potassium concentration in the waste, given the demonstrated large competing effect of this metal on cesium extraction. It was demonstrated that the upper limit for the potassium concentration in the feed ought to not exceed 0.05 M in order to maintain suitable cesium distribution ratios.

  8. FY 2012 Real Property Deferred, Actual, and Required Maintenance Reporting

    Energy Savers [EERE]

    Requirement | Department of Energy Real Property Deferred, Actual, and Required Maintenance Reporting Requirement FY 2012 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement PDF icon FY 2012 DARM Transmittal Letter and Attachment Final.pdf More Documents & Publications FY 2013 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement Real Property Maintenance Reporting Requirement Memorandum (July 13, 2010)

  9. FY 2013 Real Property Deferred, Actual, and Required Maintenance Reporting

    Energy Savers [EERE]

    Requirement | Department of Energy Real Property Deferred, Actual, and Required Maintenance Reporting Requirement FY 2013 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement PDF icon FY 2013 DARM Transmittal Letter and Attachment Final.pdf More Documents & Publications FY 2012 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement FY_09_DM_RM_AM_Reporting_Memo_and_attachment_072009.pdf Real Property Maintenance Reporting Requirement

  10. Table 14a. Average Electricity Prices, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    a. Average Electricity Prices, Projected vs. Actual" "Projected Price in Constant Dollars" " (constant dollars, cents per kilowatt-hour in ""dollar year"" specific to each AEO)" ...

  11. Table 16. Total Energy Consumption, Projected vs. Actual Projected

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    6. Total Energy Consumption, Projected vs. Actual Projected (quadrillion Btu) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 ...

  12. Table 8. Total Natural Gas Consumption, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Actual Projected (trillion cubic feet) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 19.87 20.21 20.64 20.99 ...

  13. Table 14b. Average Electricity Prices, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    b. Average Electricity Prices, Projected vs. Actual" "Projected Price in Nominal Dollars" " (nominal dollars, cents per kilowatt-hour)" ,1993,1994,1995,1996,1997,1998,1999,2000,200...

  14. Table 14b. Average Electricity Prices, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    b. Average Electricity Prices, Projected vs. Actual Projected Price in Nominal Dollars (nominal dollars, cents per kilowatt-hour) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 ...

  15. Table 9. Natural Gas Production, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Natural Gas Production, Projected vs. Actual" "Projected" " (trillion cubic feet)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2...

  16. Table 10. Natural Gas Net Imports, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Natural Gas Net Imports, Projected vs. Actual" "Projected" " (trillion cubic feet)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,...

  17. "Table 7b. Natural Gas Price, Electric Power Sector, Actual...

    U.S. Energy Information Administration (EIA) Indexed Site

    b. Natural Gas Price, Electric Power Sector, Actual vs. Projected" "Projected Price in Nominal Dollars" " (nominal dollars per million Btu)" ,1993,1994,1995,1996,1997,1998,1999,200...

  18. Table 10. Natural Gas Net Imports, Projected vs. Actual Projected

    U.S. Energy Information Administration (EIA) Indexed Site

    Natural Gas Net Imports, Projected vs. Actual Projected (trillion cubic feet) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012...

  19. Table 4. Total Petroleum Consumption, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Petroleum Consumption, Projected vs. Actual" "Projected" " (million barrels)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",6449.55,6566.35,6643,6723.3,6810.9,6880.25,6956.9,7059.1,7124.8,7205.1,7296.35,7376.65,7446,7522.65,7595.65,7665,7712.45,7774.5 "AEO

  20. Table 6. Petroleum Net Imports, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Petroleum Net Imports, Projected vs. Actual" "Projected" " (million barrels)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",2934.6,3201.05,3361.65,3504,3657.3,3737.6,3879.95,3993.1,4098.95,4212.1,4303.35,4398.25,4474.9,4540.6,4584.4,4639.15,4668.35,4672 "AEO

  1. FRACTIONAL CRYSTALLIZATION FLOWSHEET TESTS WITH ACTUAL TANK WASTE

    SciTech Connect (OSTI)

    HERTING, D.L.

    2007-04-13

    Laboratory-scale flowsheet tests of the fractional crystallization process were conducted with actual tank waste samples in a hot cell at the 2224 Laboratory. The process is designed to separate medium-curie liquid waste into a low-curie stream for feeding to supplemental treatment and a high-curie stream for double-shell tank storage. Separations criteria (for Cesium-137 sulfate and sodium) were exceeded in all three of the flowsheet tests that were performed.

  2. FRACTIONAL CRYSTALLIZATION FLOWSHEET TESTS WITH ACTUAL TANK WASTE

    SciTech Connect (OSTI)

    HERTING, D.L.

    2006-10-18

    Laboratory-scale flowsheet tests of the fractional crystallization process were conducted with actual tank waste samples in a hot cell at the 222-S Laboratory. The process is designed to separate medium-curie liquid waste into a low-curie stream for feeding to supplemental treatment and a high-curie stream for double-shell tank storage. Separations criteria (for Cs-137 sulfate, and sodium) were exceeded in all three of the flowsheet tests that were performed.

  3. Table 12. Total Coal Consumption, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Coal Consumption, Projected vs. Actual" "Projected" " (million short tons)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",920,928,933,938,943,948,953,958,962,967,978,990,987,992,1006,1035,1061,1079 "AEO 1995",,935,940,941,947,948,951,954,958,963,971,984,992,996,1002,1013,1025,1039 "AEO

  4. Table 12. Total Coal Consumption, Projected vs. Actual Projected

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Coal Consumption, Projected vs. Actual Projected (million short tons) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 920 928 933 938 943 948 953 958 962 967 978 990 987 992 1006 1035 1061 1079 AEO 1995 935 940 941 947 948 951 954 958 963 971 984 992 996 1002 1013 1025 1039 AEO 1996 937 942 954 962 983 990 1004 1017 1027 1033 1046 1067 1070 1071 1074 1082 1087 1094 1103 AEO 1997 948 970 987 1003 1017 1020 1025 1034 1041

  5. Table 13. Coal Production, Projected vs. Actual Projected

    U.S. Energy Information Administration (EIA) Indexed Site

    Coal Production, Projected vs. Actual Projected (million short tons) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 999 1021 1041 1051 1056 1066 1073 1081 1087 1098 1107 1122 1121 1128 1143 1173 1201 1223 AEO 1995 1006 1010 1011 1016 1017 1021 1027 1033 1040 1051 1066 1076 1083 1090 1108 1122 1137 AEO 1996 1037 1044 1041 1045 1061 1070 1086 1100 1112 1121 1135 1156 1161 1167 1173 1184 1190 1203 1215 AEO 1997 1028 1052 1072 1088

  6. Table 15. Total Electricity Sales, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Electricity Sales, Projected vs. Actual" "Projected" " (billion kilowatt-hours)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",2843,2891,2928,2962,3004,3039,3071,3112,3148,3185,3228,3263,3298,3332,3371,3406,3433,3469 "AEO 1995",,2951,2967,2983,3026,3058,3085,3108,3134,3166,3204,3248,3285,3321,3357,3396,3433,3475 "AEO

  7. Table 15. Total Electricity Sales, Projected vs. Actual Projected

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Electricity Sales, Projected vs. Actual Projected (billion kilowatt-hours) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 2843 2891 2928 2962 3004 3039 3071 3112 3148 3185 3228 3263 3298 3332 3371 3406 3433 3469 AEO 1995 2951 2967 2983 3026 3058 3085 3108 3134 3166 3204 3248 3285 3321 3357 3396 3433 3475 AEO 1996 2973 2998 3039 3074 3106 3137 3173 3215 3262 3317 3363 3409 3454 3505 3553 3604 3660 3722 3775 AEO 1997 3075

  8. Table 4. Total Petroleum Consumption, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Petroleum Consumption, Projected vs. Actual Projected (million barrels) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 6450 6566 6643 6723 6811 6880 6957 7059 7125 7205 7296 7377 7446 7523 7596 7665 7712 7775 AEO 1995 6398 6544 6555 6676 6745 6822 6888 6964 7048 7147 7245 7337 7406 7472 7537 7581 7621 AEO 1996 6490 6526 6607 6709 6782 6855 6942 7008 7085 7176 7260 7329 7384 7450 7501 7545 7581 7632 7676 AEO 1997 6636 6694

  9. Table 5. Domestic Crude Oil Production, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Domestic Crude Oil Production, Projected vs. Actual" "Projected" " (million barrels)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",2507.55,2372.5,2255.7,2160.8,2087.8,2022.1,1952.75,1890.7,1850.55,1825,1799.45,1781.2,1766.6,1759.3,1777.55,1788.5,1806.75,1861.5 "AEO

  10. Table 5. Domestic Crude Oil Production, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Domestic Crude Oil Production, Projected vs. Actual Projected (million barrels) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 2508 2373 2256 2161 2088 2022 1953 1891 1851 1825 1799 1781 1767 1759 1778 1789 1807 1862 AEO 1995 2402 2307 2205 2095 2037 1967 1953 1924 1916 1905 1894 1883 1887 1887 1920 1945 1967 AEO 1996 2387 2310 2248 2172 2113 2062 2011 1978 1953 1938 1916 1920 1927 1949 1971 1986 2000 2018 2055 AEO 1997 2362 2307

  11. Table 6. Petroleum Net Imports, Projected vs. Actual Projected

    U.S. Energy Information Administration (EIA) Indexed Site

    Petroleum Net Imports, Projected vs. Actual Projected (million barrels) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 2935 3201 3362 3504 3657 3738 3880 3993 4099 4212 4303 4398 4475 4541 4584 4639 4668 4672 AEO 1995 2953 3157 3281 3489 3610 3741 3818 3920 4000 4103 4208 4303 4362 4420 4442 4460 4460 AEO 1996 3011 3106 3219 3398 3519 3679 3807 3891 3979 4070 4165 4212 4260 4289 4303 4322 4325 4347 4344 AEO 1997 3099 3245 3497

  12. Table 16. Total Energy Consumption, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Energy Consumption, Projected vs. Actual" "Projected" " (quadrillion Btu)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",88.02,89.53,90.72,91.73,92.71,93.61,94.56,95.73,96.69,97.69,98.89,100,100.79,101.7,102.7,103.6,104.3,105.23 "AEO 1995",,89.21,89.98,90.57,91.91,92.98,93.84,94.61,95.3,96.19,97.18,98.38,99.37,100.3,101.2,102.1,102.9,103.88 "AEO

  13. Table 8. Total Natural Gas Consumption, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Natural Gas Consumption, Projected vs. Actual" "Projected" " (trillion cubic feet)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",19.87,20.21,20.64,20.99,21.2,21.42,21.6,21.99,22.37,22.63,22.95,23.22,23.58,23.82,24.09,24.13,24.02,24.14 "AEO 1995",,20.82,20.66,20.85,21.21,21.65,21.95,22.12,22.25,22.43,22.62,22.87,23.08,23.36,23.61,24.08,24.23,24.59 "AEO

  14. Table 14a. Average Electricity Prices, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    a. Average Electricity Prices, Projected vs. Actual Projected Price in Constant Dollars (constant dollars, cents per kilowatt-hour in "dollar year" specific to each AEO) AEO $ Year 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 1992 6.80 6.80 6.90 6.90 6.90 6.90 7.00 7.00 7.10 7.10 7.20 7.20 7.20 7.30 7.30 7.40 7.50 7.60 AEO 1995 1993 6.80 6.80 6.70 6.70 6.70 6.70 6.70 6.80 6.80 6.90 6.90 6.90 7.00 7.00 7.10 7.10 7.20

  15. Table 17. Total Delivered Residential Energy Consumption, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Delivered Residential Energy Consumption, Projected vs. Actual Projected (quadrillion Btu) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 10.3 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.5 10.5 10.5 10.5 10.5 10.6 10.6 AEO 1995 11.0 10.8 10.8 10.8 10.8 10.8 10.8 10.7 10.7 10.7 10.7 10.7 10.7 10.7 10.8 10.8 10.9 AEO 1996 10.4 10.7 10.7 10.7 10.8 10.8 10.9 10.9 11.0 11.2 11.2 11.3 11.4 11.5 11.6 11.7 11.8 12.0 12.1

  16. Table 18. Total Delivered Commercial Energy Consumption, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Delivered Commercial Energy Consumption, Projected vs. Actual Projected (quadrillion Btu) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 6.8 6.9 6.9 7.0 7.1 7.1 7.2 7.2 7.3 7.3 7.4 7.4 7.4 7.5 7.5 7.5 7.5 7.6 AEO 1995 6.9 6.9 7.0 7.0 7.0 7.1 7.1 7.1 7.1 7.1 7.2 7.2 7.2 7.2 7.3 7.3 7.3 AEO 1996 7.1 7.2 7.2 7.3 7.3 7.4 7.4 7.5 7.6 7.6 7.7 7.7 7.8 7.9 8.0 8.0 8.1 8.2 8.2 AEO 1997 7.4 7.4 7.4 7.5 7.5 7.6 7.7 7.7 7.8 7.8 7.9 7.9

  17. Table 19. Total Delivered Industrial Energy Consumption, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Delivered Industrial Energy Consumption, Projected vs. Actual Projected (quadrillion Btu) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 25.4 25.9 26.3 26.7 27.0 27.1 26.8 26.6 26.9 27.2 27.7 28.1 28.3 28.7 29.1 29.4 29.7 30.0 AEO 1995 26.2 26.3 26.5 27.0 27.3 26.9 26.6 26.8 27.1 27.5 27.9 28.2 28.4 28.7 29.0 29.3 29.6 AEO 1996 26.5 26.6 27.3 27.5 26.9 26.5 26.7 26.9 27.2 27.6 27.9 28.2 28.3 28.5 28.7 28.9 29.2 29.4 29.6

  18. Table 20. Total Delivered Transportation Energy Consumption, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Delivered Transportation Energy Consumption, Projected vs. Actual Projected (quadrillion Btu) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 23.6 24.1 24.5 24.7 25.1 25.4 25.7 26.2 26.5 26.9 27.2 27.6 27.9 28.3 28.6 28.9 29.2 29.5 AEO 1995 23.3 24.0 24.2 24.7 25.1 25.5 25.9 26.2 26.5 26.9 27.3 27.7 28.0 28.3 28.5 28.7 28.9 AEO 1996 23.9 24.1 24.5 24.8 25.3 25.7 26.0 26.4 26.7 27.1 27.5 27.8 28.1 28.4 28.6 28.9 29.1 29.3

  19. Table 22. Energy Intensity, Projected vs. Actual Projected

    U.S. Energy Information Administration (EIA) Indexed Site

    Energy Intensity, Projected vs. Actual Projected (quadrillion Btu / $Billion 2005 Chained GDP) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 10.9 10.7 10.6 10.5 10.3 10.2 10.1 9.9 9.8 9.7 9.6 9.5 9.4 9.3 9.2 9.1 9.0 8.9 AEO 1995 10.5 10.4 10.3 10.1 10.0 9.8 9.7 9.6 9.4 9.3 9.2 9.1 9.0 8.9 8.9 8.8 8.7 AEO 1996 10.4 10.3 10.1 10.0 9.8 9.7 9.5 9.4 9.3 9.2 9.1 9.0 8.9 8.9 8.8 8.7 8.7 8.6 8.5 AEO 1997 10.0 9.9 9.8 9.7 9.6 9.5 9.4

  20. Table 9. Natural Gas Production, Projected vs. Actual Projected

    U.S. Energy Information Administration (EIA) Indexed Site

    Natural Gas Production, Projected vs. Actual Projected (trillion cubic feet) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 17.71 17.68 17.84 18.12 18.25 18.43 18.58 18.93 19.28 19.51 19.80 19.92 20.13 20.18 20.38 20.35 20.16 20.19 AEO 1995 18.28 17.98 17.92 18.21 18.63 18.92 19.08 19.20 19.36 19.52 19.75 19.94 20.17 20.28 20.60 20.59 20.88 AEO 1996 18.90 19.15 19.52 19.59 19.59 19.65 19.73 19.97 20.36 20.82 21.25 21.37 21.68

  1. Table 11b. Coal Prices to Electric Generating Plants, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    b. Coal Prices to Electric Generating Plants, Projected vs. Actual" "Projected Price in Nominal Dollars" " (nominal dollars per million Btu)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO

  2. Table 3b. Imported Refiner Acquisition Cost of Crude Oil, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    b. Imported Refiner Acquisition Cost of Crude Oil, Projected vs. Actual" "Projected Price in Nominal Dollars" " (nominal dollars per barrel)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO

  3. "Table 2. Real Gross Domestic Product Growth Trends, Projected vs. Actual"

    U.S. Energy Information Administration (EIA) Indexed Site

    Real Gross Domestic Product Growth Trends, Projected vs. Actual" "Projected Real GDP Growth Trend" " (cumulative average percent growth in projected real GDP from first year shown for each AEO)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO

  4. Actual and Estimated Energy Savings Comparison for Deep Energy Retrofits in the Pacific Northwest

    SciTech Connect (OSTI)

    Blanchard, Jeremy; Widder, Sarah H.; Giever, Elisabeth L.; Baechler, Michael C.

    2012-10-01

    Seven homes from the Pacific Northwest were selected to evaluate the differences between estimated and actual energy savings achieved from deep energy retrofits. The energy savings resulting from these retrofits were estimated, using energy modeling software, to save at least 30% on a whole-house basis. The modeled pre-retrofit energy use was trued against monthly utility bills. After the retrofits were completed, each of the homes was extensively monitored, with the exception of one home which was monitored pre-retrofit. This work is being conducted by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. This work found many discrepancies between actual and estimated energy savings and identified the potential causes for the discrepancies. The differences between actual energy use and modeled energy use also suggest improvements to improve model accuracy. The difference between monthly whole-house actual and estimated energy savings ranged from 75% more energy saved than predicted by the model to 16% less energy saved for all the monitored homes. Similarly, the annual energy savings difference was between 36% and -14%, which was estimated based on existing monitored savings because an entire year of data is not available. Thus, on average, for all six monitored homes the actual energy use is consistently less than estimates, indicating home owners are saving more energy than estimated. The average estimated savings for the eight month monitoring period is 43%, compared to an estimated savings average of 31%. Though this average difference is only 12%, the range of inaccuracies found for specific end-uses is far greater and are the values used to directly estimate energy savings from specific retrofits. Specifically, the monthly post-retrofit energy use differences for specific end-uses (i.e., heating, cooling, hot water, appliances, etc.) ranged from 131% under-predicted to 77% over-predicted by the model with respect to monitored energy use. Many of the discrepancies were associated with occupant behavior which influences energy use, dramatically in some cases, actual versus modeled weather differences, modeling input limitations, and complex homes that are difficult to model. The discrepancy between actual and estimated energy use indicates a need for better modeling tools and assumptions. Despite the best efforts of researchers, the estimated energy savings are too inaccurate to determine reliable paybacks for retrofit projects. While the monitored data allows researchers to understand why these differences exist, it is not cost effective to monitor each home with the level of detail presented here. Therefore an appropriate balance between modeling and monitoring must be determined for more widespread application in retrofit programs and the home performance industry. Recommendations to address these deficiencies include: (1) improved tuning process for pre-retrofit energy use, which currently utilized broad-based monthly utility bills; (2) developing simple occupant-based energy models that better address the many different occupant types and their impact on energy use; (3) incorporating actual weather inputs to increase accuracy of the tuning process, which uses utility bills from specific time period; and (4) developing simple, cost-effective monitoring solutions for improved model tuning.

  5. Reaction chemistry of nitrogen species in hydrothermal systems: Simple reactions, waste simulants, and actual wastes

    SciTech Connect (OSTI)

    Dell`Orco, P.; Luan, L.; Proesmans, P.; Wilmanns, E.

    1995-02-01

    Results are presented from hydrothermal reaction systems containing organic components, nitrogen components, and an oxidant. Reaction chemistry observed in simple systems and in simple waste simulants is used to develop a model which presents global nitrogen chemistry in these reactive systems. The global reaction path suggested is then compared with results obtained for the treatment of an actual waste stream containing only C-N-0-H species.

  6. "Table 21. Total Energy Related Carbon Dioxide Emissions, Projected vs. Actual"

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Energy Related Carbon Dioxide Emissions, Projected vs. Actual" "Projected" " (million metric tons)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",5060,5129.666667,5184.666667,5239.666667,5287.333333,5335,5379,5437.666667,5481.666667,5529.333333,5599,5657.666667,5694.333333,5738.333333,5797,5874,5925.333333,5984 "AEO

  7. Dose Rate Analysis Capability for Actual Spent Fuel Transportation Cask Contents

    SciTech Connect (OSTI)

    Radulescu, Georgeta; Lefebvre, Robert A; Peplow, Douglas E.; Williams, Mark L; Scaglione, John M

    2014-01-01

    The approved contents for a U.S. Nuclear Regulatory Commission (NRC) licensed spent nuclear fuel casks are typically based on bounding used nuclear fuel (UNF) characteristics. However, the contents of the UNF canisters currently in storage at independent spent fuel storage installations are considerably heterogeneous in terms of fuel assembly burnup, initial enrichment, decay time, cladding integrity, etc. Used Nuclear Fuel Storage, Transportation & Disposal Analysis Resource and Data System (UNF ST&DARDS) is an integrated data and analysis system that facilitates automated cask-specific safety analyses based on actual characteristics of the as-loaded UNF. The UNF-ST&DARDS analysis capabilities have been recently expanded to include dose rate analysis of as-loaded transportation packages. Realistic dose rate values based on actual canister contents may be used in place of bounding dose rate values to support development of repackaging operations procedures, evaluation of radiation-related transportation risks, and communication with stakeholders. This paper describes the UNF-ST&DARDS dose rate analysis methodology based on actual UNF canister contents and presents sample dose rate calculation results.

  8. Treatability studies of actual listed waste sludges from the Oak Ridge Reservation (ORR)

    SciTech Connect (OSTI)

    Jantzen, C.M.; Peeler, D.K.; Gilliam, T.M.; Bleier, A.; Spence, R.D.

    1996-05-06

    Oak Ridge National Laboratory (ORNL) and Savannah River Technology Center (SRTC) are investigating vitrification for various low-level and mixed wastes on the Oak Ridge Reservation (ORR). Treatability studies have included surrogate waste formulations at the laboratory-, pilot-, and field-scales and actual waste testing at the laboratory- and pilot-scales. The initial waste to be processing through SRTC`s Transportable Vitrification System (TVS) is the K-1407-B and K-1407-C (B/C) Pond sludge waste which is a RCRA F-listed waste. The B/C ponds at the ORR K-25 site were used as holding and settling ponds for various waste water treatment streams. Laboratory-, pilot-, and field- scale ``proof-of-principle`` demonstrations are providing needed operating parameters for the planned field-scale demonstration with actual B/C Pond sludge waste at ORR. This report discusses the applied systems approach to optimize glass compositions for this particular waste stream through laboratory-, pilot-, and field-scale studies with surrogate and actual B/C waste. These glass compositions will maximize glass durability and waste loading while optimizing melt properties which affect melter operation, such as melt viscosity and melter refractory corrosion. Maximum waste loadings minimize storage volume of the final waste form translating into considerable cost savings.

  9. Actual versus predicted impacts of three ethanol plants on aquatic and terrestrial resources

    SciTech Connect (OSTI)

    Eddlemon, G.K.; Webb, J.W.; Hunsaker, D.B. Jr.; Miller, R.L.

    1993-03-15

    To help reduce US dependence on imported petroleum, Congress passed the Energy Security Act of 1980 (public Law 96-294). This legislation authorized the US Department of Energy (DOE) to promote expansion of the fuel alcohol industry through, among other measures, its Alcohol Fuels Loan Guarantee Program. Under this program, selected proposals for the conversion of plant biomass into fuel-grade ethanol would be granted loan guarantees. of 57 applications submitted for loan guarantees to build and operate ethanol fuel projects under this program, 11 were considered by DOE to have the greatest potential for satisfying DOE`s requirements and goals. In accordance with the National Environmental Policy Act (NEPA), DOE evaluated the potential impacts of proceeding with the Loan Guarantee Program in a programmatic environmental assessment (DOE 1981) that resulted in a finding of no significant impact (FANCY) (47 Federal Register 34, p. 7483). The following year, DOE conducted site-specific environmental assessments (EAs) for 10 of the proposed projects. These F-As predicted no significant environmental impacts from these projects. Eventually, three ethanol fuel projects received loan guarantees and were actually built: the Tennol Energy Company (Tennol; DOE 1982a) facility near Jasper in southeastern Tennessee; the Agrifuels Refining Corporation (Agrifuels; DOE 1985) facility near New Liberia in southern Louisiana; and the New Energy Company of Indiana (NECI; DOE 1982b) facility in South Bend, Indiana. As part of a larger retrospective examination of a wide range of environmental effects of ethanol fuel plants, we compared the actual effects of the three completed plants on aquatic and terrestrial resources with the effects predicted in the NEPA EAs several years earlier. A secondary purpose was to determine: Why were there differences, if any, between actual effects and predictions? How can assessments be improved and impacts reduced?

  10. TESTING OF THE SPINTEK ROTARY MICROFILTER USING ACTUAL HANFORD WASTE SAMPLES

    SciTech Connect (OSTI)

    HUBER HJ

    2010-04-13

    The SpinTek rotary microfilter was tested on actual Hanford tank waste. The samples were a composite of archived Tank 241-AN-105 material and a sample representing single-shell tanks (SST). Simulants of the two samples have been used in non-rad test runs at the 222-S laboratory and at Savannah River National Laboratory (SRNL). The results of these studies are compared in this report. Two different nominal pore sizes for the sintered steel rotating disk filter were chosen: 0.5 and 0.1 {micro}m. The results suggest that the 0.5-{micro}m disk is preferable for Hanford tank waste for the following reasons: (1) The filtrate clarity is within the same range (<<4 ntu for both disks); (2) The filtrate flux is in general higher for the 0.5-{micro}m disk; and (3) The 0.1-{micro}m disk showed a higher likelihood of fouling. The filtrate flux of the actual tank samples is generally in the range of 20-30% compared to the equivalent non-rad tests. The AN-105 slurries performed at about twice the filtrate flux of the SST slurries. The reason for this difference has not been identified. Particle size distributions in both cases are very similar; comparison of the chemical composition is not conclusive. The sole hint towards what material was stuck in the filter pore holes came from the analysis of the dried flakes from the surface of the fouled 0.1-{micro}m disk. A cleaning approach developed by SRNL personnel to deal with fouled disks has been found adaptable when using actual Hanford samples. The use of 1 M nitric acid improved the filtrate flux by approximately two times; using the same simulants as in the non-rad test runs showed that the filtrate flux was restored to 1/2 of its original amount.

  11. Table 21. Total Energy Related Carbon Dioxide Emissions, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Energy Related Carbon Dioxide Emissions, Projected vs. Actual Projected (million metric tons) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 5060 5130 5185 5240 5287 5335 5379 5438 5482 5529 5599 5658 5694 5738 5797 5874 5925 5984 AEO 1995 5137 5174 5188 5262 5309 5361 5394 5441 5489 5551 5621 5680 5727 5775 5841 5889 5944 AEO 1996 5182 5224 5295 5355 5417 5464 5525 5589 5660 5735 5812 5879 5925 5981 6030 6087 6142 6203

  12. Table 3a. Imported Refiner Acquisition Cost of Crude Oil, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    a. Imported Refiner Acquisition Cost of Crude Oil, Projected vs. Actual" "Projected Price in Constant Dollars" " (constant dollars per barrel in ""dollar year"" specific to each AEO)" ,"AEO $ Year",1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",1992,16.69,16.42999,16.9899,17.66,18.28,19.0599,19.89,20.72,21.65,22.61,23.51,24.29,24.9,25.6,26.3,27,27.64,28.16

  13. Method and apparatus for distinguishing actual sparse events from sparse event false alarms

    DOE Patents [OSTI]

    Spalding, Richard E. (Albuquerque, NM); Grotbeck, Carter L. (Albuquerque, NM)

    2000-01-01

    Remote sensing method and apparatus wherein sparse optical events are distinguished from false events. "Ghost" images of actual optical phenomena are generated using an optical beam splitter and optics configured to direct split beams to a single sensor or segmented sensor. True optical signals are distinguished from false signals or noise based on whether the ghost image is presence or absent. The invention obviates the need for dual sensor systems to effect a false target detection capability, thus significantly reducing system complexity and cost.

  14. "Table 19. Total Delivered Industrial Energy Consumption, Projected vs. Actual"

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Delivered Industrial Energy Consumption, Projected vs. Actual" "Projected" " (quadrillion Btu)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",25.43,25.904,26.303,26.659,26.974,27.062,26.755,26.598,26.908,27.228,27.668,28.068,28.348,28.668,29.068,29.398,29.688,30.008 "AEO

  15. ACTUAL WASTE TESTING OF GYCOLATE IMPACTS ON THE SRS TANK FARM

    SciTech Connect (OSTI)

    Martino, C.

    2014-05-28

    Glycolic acid is being studied as a replacement for formic acid in the Defense Waste Processing Facility (DWPF) feed preparation process. After implementation, the recycle stream from DWPF back to the high-level waste Tank Farm will contain soluble sodium glycolate. Most of the potential impacts of glycolate in the Tank Farm were addressed via a literature review and simulant testing, but several outstanding issues remained. This report documents the actual-waste tests to determine the impacts of glycolate on storage and evaporation of Savannah River Site high-level waste. The objectives of this study are to address the following: ? Determine the extent to which sludge constituents (Pu, U, Fe, etc.) dissolve (the solubility of sludge constituents) in the glycolate-containing 2H-evaporator feed. ? Determine the impact of glycolate on the sorption of fissile (Pu, U, etc.) components onto sodium aluminosilicate solids. The first objective was accomplished through actual-waste testing using Tank 43H and 38H supernatant and Tank 51H sludge at Tank Farm storage conditions. The second objective was accomplished by contacting actual 2H-evaporator scale with the products from the testing for the first objective. There is no anticipated impact of up to 10 g/L of glycolate in DWPF recycle to the Tank Farm on tank waste component solubilities as investigated in this test. Most components were not influenced by glycolate during solubility tests, including major components such as aluminum, sodium, and most salt anions. There was potentially a slight increase in soluble iron with added glycolate, but the soluble iron concentration remained so low (on the order of 10 mg/L) as to not impact the iron to fissile ratio in sludge. Uranium and plutonium appear to have been supersaturated in 2H-evaporator feed solution mixture used for this testing. As a result, there was a reduction of soluble uranium and plutonium as a function of time. The change in soluble uranium concentration was independent of added glycolate concentration. The change in soluble plutonium content was dependent on the added glycolate concentration, with higher levels of glycolate (5 g/L and 10 g/L) appearing to suppress the plutonium solubility. The inclusion of glycolate did not change the dissolution of or sorption onto actual-waste 2H-evaporator pot scale to an extent that will impact Tank Farm storage and concentration. The effects that were noted involved dissolution of components from evaporator scale and precipitation of components onto evaporator scale that were independent of the level of added glycolate.

  16. PERFORMANCE TESTING OF THE NEXT-GENERATION CSSX SOLVENT WITH ACTUAL SRS TANK WASTE

    SciTech Connect (OSTI)

    Pierce, R.; Peters, T.; Crowder, M.; Fink, S.

    2011-11-01

    Efforts are underway to qualify the Next-Generation Solvent for the Caustic Side Solvent Extraction (CSSX) process. Researchers at multiple national laboratories have been involved in this effort. As part of the effort to qualify the solvent extraction system at the Savannah River Site (SRS), SRNL performed a number of tests at various scales. First, SRNL completed a series of batch equilibrium, or Extraction-Scrub-Strip (ESS), tests. These tests used {approx}30 mL of Next-Generation Solvent and either actual SRS tank waste, or waste simulant solutions. The results from these cesium mass transfer tests were used to predict solvent behavior under a number of conditions. At a larger scale, SRNL assembled 12 stages of 2-cm (diameter) centrifugal contactors. This rack of contactors is structurally similar to one tested in 2001 during the demonstration of the baseline CSSX process. Assembly and mechanical testing found no issues. SRNL performed a nonradiological test using 35 L of cesium-spiked caustic waste simulant and 39 L of actual tank waste. Test results are discussed; particularly those related to the effectiveness of extraction.

  17. Filtration and Leach Testing for REDOX Sludge and S-Saltcake Actual Waste Sample Composites

    SciTech Connect (OSTI)

    Shimskey, Rick W.; Billing, Justin M.; Buck, Edgar C.; Daniel, Richard C.; Draper, Kathryn E.; Edwards, Matthew K.; Geeting, John GH; Hallen, Richard T.; Jenson, Evan D.; Kozelisky, Anne E.; MacFarlan, Paul J.; Peterson, Reid A.; Snow, Lanee A.; Swoboda, Robert G.

    2009-02-20

    A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan.( ) The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Under test plan TP-RPP-WTP-467, eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. Under this test plan, a waste-testing program was implemented that included: • Homogenizing the archive samples by group as defined in the test plan • Characterizing the homogenized sample groups • Performing parametric leaching testing on each group for compounds of interest • Performing bench-top filtration/leaching tests in the hot cell for each group to simulate filtration and leaching activities if they occurred in the UFP2 vessel of the WTP Pretreatment Facility. This report focuses on filtration/leaching tests performed on two of the eight waste composite samples and follow-on parametric tests to support aluminum leaching results from those tests.

  18. Table 11a. Coal Prices to Electric Generating Plants, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    a. Coal Prices to Electric Generating Plants, Projected vs. Actual" "Projected Price in Constant Dollars" " (constant dollars per million Btu in ""dollar year"" specific to each AEO)" ,"AEO $ Year",1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",1992,1.4699,1.4799,1.53,1.57,1.58,1.57,1.61,1.63,1.68,1.69,1.7,1.72,1.7,1.76,1.79,1.81,1.88,1.92 "AEO

  19. Table 11a. Coal Prices to Electric Generating Plants, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    a. Coal Prices to Electric Generating Plants, Projected vs. Actual Projected Price in Constant Dollars (constant dollars per million Btu in "dollar year" specific to each AEO) AEO $ Year 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 1992 1.47 1.48 1.53 1.57 1.58 1.57 1.61 1.63 1.68 1.69 1.70 1.72 1.70 1.76 1.79 1.81 1.88 1.92 AEO 1995 1993 1.39 1.39 1.38 1.40 1.40 1.39 1.39 1.42 1.41 1.43 1.44 1.45 1.46 1.46 1.46 1.47

  20. Table 3a. Imported Refiner Acquisition Cost of Crude Oil, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    a. Imported Refiner Acquisition Cost of Crude Oil, Projected vs. Actual Projected Price in Constant Dollars (constant dollars per barrel in "dollar year" specific to each AEO) AEO $ Year 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 1992 16.69 16.43 16.99 17.66 18.28 19.06 19.89 20.72 21.65 22.61 23.51 24.29 24.90 25.60 26.30 27.00 27.64 28.16 AEO 1995 1993 14.90 16.41 16.90 17.45 18.00 18.53 19.13 19.65 20.16 20.63

  1. Table 3b. Imported Refiner Acquisition Cost of Crude Oil, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    b. Imported Refiner Acquisition Cost of Crude Oil, Projected vs. Actual Projected Price in Nominal Dollars (nominal dollars per barrel) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 17.06 17.21 18.24 19.43 20.64 22.12 23.76 25.52 27.51 29.67 31.86 34.00 36.05 38.36 40.78 43.29 45.88 48.37 AEO 1995 15.24 17.27 18.23 19.26 20.39 21.59 22.97 24.33 25.79 27.27 28.82 30.38 32.14 33.89 35.85 37.97 40.28 AEO 1996 17.16 17.74 18.59

  2. Table 7a. Natural Gas Price, Electric Power Sector, Actual vs. Projected

    U.S. Energy Information Administration (EIA) Indexed Site

    a. Natural Gas Price, Electric Power Sector, Actual vs. Projected Projected Price in Constant Dollars (constant dollars per million Btu in "dollar year" specific to each AEO) AEO $ Year 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 1992 2.44 2.48 2.57 2.66 2.70 2.79 2.84 2.92 3.04 3.16 3.25 3.36 3.51 3.60 3.77 3.91 3.97 4.08 AEO 1995 1993 2.39 2.48 2.42 2.45 2.45 2.53 2.59 2.78 2.91 3.10 3.24 3.38 3.47 3.53 3.61 3.68

  3. Characterization, Leaching, and Filtrations Testing of Ferrocyanide Tank sludge (Group 8) Actual Waste Composite

    SciTech Connect (OSTI)

    Fiskum, Sandra K.; Billing, Justin M.; Crum, J. V.; Daniel, Richard C.; Edwards, Matthew K.; Shimskey, Rick W.; Peterson, Reid A.; MacFarlan, Paul J.; Buck, Edgar C.; Draper, Kathryn E.; Kozelisky, Anne E.

    2009-02-28

    This is the final report in a series of eight reports defining characterization, leach, and filtration testing of a wide variety of Hanford tank waste sludges. The information generated from this series is intended to supplement the Waste Treatment and Immobilization Plant (WTP) project understanding of actual waste behaviors associated with tank waste sludge processing through the pretreatment portion of the WTP. The work described in this report presents information on a high-iron waste form, specifically the ferrocyanide tank waste sludge. Iron hydroxide has been shown to pose technical challenges during filtration processing; the ferrocyanide tank waste sludge represented a good source of the high-iron matrix to test the filtration processing.

  4. "Table 17. Total Delivered Residential Energy Consumption, Projected vs. Actual"

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Delivered Residential Energy Consumption, Projected vs. Actual" "Projected" " (quadrillion Btu)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",10.31,10.36,10.36,10.37,10.38,10.4,10.4,10.41,10.43,10.43,10.44,10.45,10.46,10.49,10.51,10.53,10.56,10.6 "AEO 1995",,10.96,10.8,10.81,10.81,10.79,10.77,10.75,10.73,10.72,10.7,10.7,10.69,10.7,10.72,10.75,10.8,10.85 "AEO

  5. "Table 18. Total Delivered Commercial Energy Consumption, Projected vs. Actual"

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Delivered Commercial Energy Consumption, Projected vs. Actual" "Projected" " (quadrillion Btu)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",6.82,6.87,6.94,7,7.06,7.13,7.16,7.22,7.27,7.32,7.36,7.38,7.41,7.45,7.47,7.5,7.51,7.55 "AEO 1995",,6.94,6.9,6.95,6.99,7.02,7.05,7.08,7.09,7.11,7.13,7.15,7.17,7.19,7.22,7.26,7.3,7.34 "AEO

  6. "Table 20. Total Delivered Transportation Energy Consumption, Projected vs. Actual"

    U.S. Energy Information Administration (EIA) Indexed Site

    Total Delivered Transportation Energy Consumption, Projected vs. Actual" "Projected" " (quadrillion Btu)" ,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",23.62,24.08,24.45,24.72,25.06,25.38,25.74,26.16,26.49,26.85,27.23,27.55,27.91,28.26,28.61,28.92,29.18,29.5 "AEO 1995",,23.26,24.01,24.18,24.69,25.11,25.5,25.86,26.15,26.5,26.88,27.28,27.66,27.99,28.25,28.51,28.72,28.94 "AEO

  7. "Table 7a. Natural Gas Price, Electric Power Sector, Actual vs. Projected"

    U.S. Energy Information Administration (EIA) Indexed Site

    a. Natural Gas Price, Electric Power Sector, Actual vs. Projected" "Projected Price in Constant Dollars" " (constant dollars per million Btu in ""dollar year"" specific to each AEO)" ,"AEO $ Year",1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,2012,2013 "AEO 1994",1992,2.44,2.48,2.57,2.66,2.7,2.79,2.84,2.92,3.04,3.16,3.25,3.36,3.51,3.6,3.77,3.91,3.97,4.08 "AEO

  8. An insight into actual energy use and its drivers in high-performance buildings

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Li, Cheng; Hong, Tianzhen; Yan, Da

    2014-07-12

    Using portfolio analysis and individual detailed case studies, we studied the energy performance and drivers of energy use in 51 high-performance office buildings in the U.S., Europe, China, and other parts of Asia. Portfolio analyses revealed that actual site energy use intensity (EUI) of the study buildings varied by a factor of as much as 11, indicating significant variation in real energy use in HPBs worldwide. Nearly half of the buildings did not meet the American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE) Standard 90.1-2004 energy target, raising questions about whether a building’s certification as high performing accuratelymore » indicates that a building is energy efficient and suggesting that improvement in the design and operation of HPBs is needed to realize their energy-saving potential. We studied the influence of climate, building size, and building technologies on building energy performance and found that although all are important, none are decisive factors in building energy use. EUIs were widely scattered in all climate zones. There was a trend toward low energy use in small buildings, but the correlation was not absolute; some small HPBs exhibited high energy use, and some large HPBs exhibited low energy use. We were unable to identify a set of efficient technologies that correlated directly to low EUIs. In two case studies, we investigated the influence of occupant behavior as well as operation and maintenance on energy performance and found that both play significant roles in realizing energy savings. We conclude that no single factor determines the actual energy performance of HPBs, and adding multiple efficient technologies does not necessarily improve building energy performance; therefore, an integrated design approach that takes account of climate, technology, occupant behavior, and operations and maintenance practices should be implemented to maximize energy savings in HPBs. As a result, these findings are intended to help architects, engineers, operators, and policy makers improve the design and operation of HPBs.« less

  9. An insight into actual energy use and its drivers in high-performance buildings

    SciTech Connect (OSTI)

    Li, Cheng; Hong, Tianzhen; Yan, Da

    2014-07-12

    Using portfolio analysis and individual detailed case studies, we studied the energy performance and drivers of energy use in 51 high-performance office buildings in the U.S., Europe, China, and other parts of Asia. Portfolio analyses revealed that actual site energy use intensity (EUI) of the study buildings varied by a factor of as much as 11, indicating significant variation in real energy use in HPBs worldwide. Nearly half of the buildings did not meet the American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE) Standard 90.1-2004 energy target, raising questions about whether a building’s certification as high performing accurately indicates that a building is energy efficient and suggesting that improvement in the design and operation of HPBs is needed to realize their energy-saving potential. We studied the influence of climate, building size, and building technologies on building energy performance and found that although all are important, none are decisive factors in building energy use. EUIs were widely scattered in all climate zones. There was a trend toward low energy use in small buildings, but the correlation was not absolute; some small HPBs exhibited high energy use, and some large HPBs exhibited low energy use. We were unable to identify a set of efficient technologies that correlated directly to low EUIs. In two case studies, we investigated the influence of occupant behavior as well as operation and maintenance on energy performance and found that both play significant roles in realizing energy savings. We conclude that no single factor determines the actual energy performance of HPBs, and adding multiple efficient technologies does not necessarily improve building energy performance; therefore, an integrated design approach that takes account of climate, technology, occupant behavior, and operations and maintenance practices should be implemented to maximize energy savings in HPBs. As a result, these findings are intended to help architects, engineers, operators, and policy makers improve the design and operation of HPBs.

  10. BENCH-SCALE STEAM REFORMING OF ACTUAL TANK 48H WASTE

    SciTech Connect (OSTI)

    Burket, P; Gene Daniel, G; Charles Nash, C; Carol Jantzen, C; Michael Williams, M

    2008-09-25

    Fluidized Bed Steam Reforming (FBSR) has been demonstrated to be a viable technology to remove >99% of the organics from Tank 48H simulant, to remove >99% of the nitrate/nitrite from Tank 48H simulant, and to form a solid product that is primarily carbonate based. The technology was demonstrated in October of 2006 in the Engineering Scale Test Demonstration Fluidized Bed Steam Reformer1 (ESTD FBSR) at the Hazen Research Inc. (HRI) facility in Golden, CO. The purpose of the Bench-scale Steam Reformer (BSR) testing was to demonstrate that the same reactions occur and the same product is formed when steam reforming actual radioactive Tank 48H waste. The approach used in the current study was to test the BSR with the same Tank 48H simulant and same Erwin coal as was used at the ESTD FBSR under the same operating conditions. This comparison would allow verification that the same chemical reactions occur in both the BSR and ESTD FBSR. Then, actual radioactive Tank 48H material would be steam reformed in the BSR to verify that the actual tank 48H sample reacts the same way chemically as the simulant Tank 48H material. The conclusions from the BSR study and comparison to the ESTD FBSR are the following: (1) A Bench-scale Steam Reforming (BSR) unit was successfully designed and built that: (a) Emulated the chemistry of the ESTD FBSR Denitration Mineralization Reformer (DMR) and Carbon Reduction Reformer (CRR) known collectively as the dual reformer flowsheet. (b) Measured and controlled the off-gas stream. (c) Processed real (radioactive) Tank 48H waste. (d) Met the standards and specifications for radiological testing in the Savannah River National Laboratory (SRNL) Shielded Cells Facility (SCF). (2) Three runs with radioactive Tank 48H material were performed. (3) The Tetraphenylborate (TPB) was destroyed to > 99% for all radioactive Bench-scale tests. (4) The feed nitrate/nitrite was destroyed to >99% for all radioactive BSR tests the same as the ESTD FBSR. (5) The radioactive Tank 48H DMR product was primarily made up of soluble carbonates. The three most abundant species were thermonatrite, [Na{sub 2}CO{sub 3} {center_dot} H{sub 2}O], sodium carbonate, [Na{sub 2}CO{sub 3}], and trona, [Na{sub 3}H(CO{sub 3}){sub 2} {center_dot} 2H{sub 2}O] the same as the ESTD FBSR. (6) Insoluble solids analyzed by X-Ray Diffraction (XRD) did not detect insoluble carbonate species. However, they still may be present at levels below 2 wt%, the sensitivity of the XRD methodology. Insoluble solids XRD characterization indicated that various Fe/Ni/Cr/Mn phases are present. These crystalline phases are associated with the insoluble sludge components of Tank 48H slurry and impurities in the Erwin coal ash. The percent insoluble solids, which mainly consist of un-burnt coal and coal ash, in the products were 4 to 11 wt% for the radioactive runs. (7) The Fe{sup +2}/Fe{sub total} REDOX measurements ranged from 0.58 to 1 for the three radioactive Bench-scale tests. REDOX measurements > 0.5 showed a reducing atmosphere was maintained in the DMR indicating that pyrolysis was occurring. (8) Greater than 90% of the radioactivity was captured in the product for all three runs. (9) The collective results from the FBSR simulant tests and the BSR simulant tests indicate that the same chemistry occurs in the two reactors. (10) The collective results from the BSR simulant runs and the BSR radioactive waste runs indicates that the same chemistry occurs in the simulant as in the real waste. The FBSR technology has been proven to destroy the organics and nitrates in the Tank 48H waste and form the anticipated solid carbonate phases as expected.

  11. Actual Versus Estimated Utility Factor of a Large Set of Privately Owned Chevrolet Volts

    SciTech Connect (OSTI)

    John Smart; Thomas Bradley; Stephen Schey

    2014-04-01

    In order to determine the overall fuel economy of a plug-in hybrid electric vehicle (PHEV), the amount of operation in charge depleting (CD) versus charge sustaining modes must be determined. Mode of operation is predominantly dependent on customer usage of the vehicle and is therefore highly variable. The utility factor (UF) concept was developed to quantify the distance a group of vehicles has traveled or may travel in CD mode. SAE J2841 presents a UF calculation method based on data collected from travel surveys of conventional vehicles. UF estimates have been used in a variety of areas, including the calculation of window sticker fuel economy, policy decisions, and vehicle design determination. The EV Project, a plug-in electric vehicle charging infrastructure demonstration being conducted across the United States, provides the opportunity to determine the real-world UF of a large group of privately owned Chevrolet Volt extended range electric vehicles. Using data collected from Volts enrolled in The EV Project, this paper compares the real-world UF of two groups of Chevrolet Volts to estimated UF's based on J2841. The actual observed fleet utility factors (FUF) for the MY2011/2012 and MY2013 Volt groups studied were observed to be 72% and 74%, respectively. Using the EPA CD ranges, the method prescribed by J2841 estimates a FUF of 65% and 68% for the MY2011/2012 and MY2013 Volt groups, respectively. Volt drivers achieved higher percentages of distance traveled in EV mode for two reasons. First, they had fewer long-distance travel days than drivers in the national travel survey referenced by J2841. Second, they charged more frequently than the J2841 assumption of once per day - drivers of Volts in this study averaged over 1.4 charging events per day. Although actual CD range varied widely as driving conditions varied, the average CD ranges for the two Volt groups studied matched the EPA CD range estimates, so CD range variation did not affect FUF results.

  12. Table 11b. Coal Prices to Electric Generating Plants, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    b. Coal Prices to Electric Generating Plants, Projected vs. Actual Projected Price in Nominal Dollars (nominal dollars per million Btu) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 1.50 1.55 1.64 1.73 1.78 1.82 1.92 2.01 2.13 2.22 2.30 2.41 2.46 2.64 2.78 2.90 3.12 3.30 AEO 1995 1.42 1.46 1.49 1.55 1.59 1.62 1.67 1.76 1.80 1.89 1.97 2.05 2.13 2.21 2.28 2.38 2.50 AEO 1996 1.35 1.35 1.37 1.39 1.42 1.46 1.50 1.56 1.62 1.67 1.75

  13. Table 2. Real Gross Domestic Product Growth Trends, Projected vs. Actual

    U.S. Energy Information Administration (EIA) Indexed Site

    Real Gross Domestic Product Growth Trends, Projected vs. Actual Projected Real GDP Growth Trend (cumulative average percent growth in projected real GDP from first year shown for each AEO) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 3.09 3.15 2.86 2.78 2.73 2.65 2.62 2.60 2.56 2.53 2.52 2.49 2.45 2.41 2.40 2.36 2.32 2.29 AEO 1995 3.66 2.77 2.53 2.71 2.67 2.61 2.55 2.48 2.46 2.45 2.45 2.43 2.39 2.35 2.31 2.27 2.24 AEO 1996 2.61

  14. Table 7b. Natural Gas Price, Electric Power Sector, Actual vs. Projected

    U.S. Energy Information Administration (EIA) Indexed Site

    b. Natural Gas Price, Electric Power Sector, Actual vs. Projected Projected Price in Nominal Dollars (nominal dollars per million Btu) 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 AEO 1994 2.49 2.60 2.76 2.93 3.05 3.24 3.39 3.60 3.86 4.15 4.40 4.70 5.08 5.39 5.85 6.27 6.59 7.01 AEO 1995 2.44 2.61 2.61 2.70 2.78 2.95 3.11 3.44 3.72 4.10 4.43 4.78 5.07 5.33 5.64 5.95 6.23 AEO 1996 2.08 2.19 2.20 2.39 2.47 2.54 2.64 2.74 2.84 2.95 3.09

  15. FRACTIONAL CRYSTALLIZATION LABORATORY TESTING FOR INCLUSION & COPRECIPITATION WITH ACTUAL TANK WASTE

    SciTech Connect (OSTI)

    WARRANT, R.W.

    2006-12-11

    Fractional crystallization is being considered as a pretreatment method to support supplemental treatment of retrieved single-shell tank (SST) saltcake waste at the Hanford Site. The goal of the fractional crystallization process is to optimize the separation of the radioactivity (radionuclides) from the saltcake waste and send it to the Waste Treatment and Immobilization Plant and send the bulk of the saltcake to the supplemental treatment plant (bulk vitrification). The primary factors that influence the separation efficiency are (1) solid/liquid separation efficiency, (2) contaminant inclusions, and (3) co-precipitation. This is a report of testing for factors (2) and (3) with actual tank waste samples. For the purposes of this report, contaminant inclusions are defined as the inclusion of supernatant, containing contaminating radionuclides, in a pocket within the precipitating saltcake crystals. Co-precipitation is defined as the simultaneous precipitation of a saltcake crystal with a contaminating radionuclide. These two factors were tested for various potential fractional crystallization product salts by spiking the composite tank waste samples (SST Early or SST Late, external letter CH2M-0600248, ''Preparation of Composite Tank Waste Samples for ME-21 Project'') with the desired target salt and then evaporating to precipitate that salt. SST Early represents the typical composition of dissolved saltcake early in the retrieval process, and SST Late represents the typical composition during the later stages of retrieval.

  16. Relationship between self-reported activity levels and actual heart rates in teenagers

    SciTech Connect (OSTI)

    Terblanche, A.P.S.; Ozkaynak, H.; Spengler, J.D.; Butler, D.A. )

    1991-08-01

    A study was designed to explore the relationship between self-reported activity levels and actual heart rate (HR) as measured by a portable heart rate monitor. Twenty-two teenagers (8 boys, 14 girls, median age of 16) from Watertown High School, Massachusetts participated in this pilot study which involved continuous monitoring of HR during normal daily activities and simultaneous completion of a time-activity diary. There were 31 successful monitoring sessions ranging from 1.9 to 17 hours with a median monitoring time of 12.6 hours. Four unsuccessful monitoring sessions were experienced due to equipment failure. Apart from participant cooperation, the single most important factor affecting the feasibility of continuous heart rate monitoring was found to be equipment design. Th overall average heart rate observed was 88.4 bpm (SD = 24.3). An individual's correlation coefficient for perceived activity level (documented in half-hour intervals) and heart rate (averaged over the half-hour intervals) varied from 0.24 to 0.89. More than half of the correlation coefficients were below 0.40. There was a significant difference between average heart rate for time spent indoors (90 bpm) versus outdoors (103 bpm) even after correcting for sleeping time. It is concluded that continuous HR monitoring with simultaneous completion of a time/activity dairy is feasible and is a promising source of information for studies on exposure to air pollutants.

  17. Predicted Versus Actual Savings for a Low-Rise Multifamily Retrofit in Boulder, Colorado

    SciTech Connect (OSTI)

    Arena, L.; Williamson, J.

    2013-11-01

    To determine the most cost-effective methods of improving buildings, accurate analysis and prediction of the energy use of existing buildings is essential. However, multiple studies confirm that analysis methods tend to over-predict energy use in poorly insulated, leaky homes and thus, the savings associated with improving those homes. In this project, the Building America CARB team evaluated the retrofit of a multifamily building in Boulder, CO. The updated property is a 37 unit, 2 story apartment complex built in 1950, which underwent renovations in early 2009 to bring it into compliance with Boulder, CO's SmartRegs ordinance. Goals of the study were to: 1) evaluate predicted versus actual savings due to the improvements, 2) identify areas where the modeling assumptions may need to be changed, and 3) determine common changes made by renters that would negatively impact energy savings. Other issues that were investigated include the effects of improving building efficiency on tenant comfort, the impact on tenant turnover rates, and the potential market barriers for this type of community scale project.

  18. Predicted Versus Actual Savings for a Low-Rise Multifamily Retrofit in Boulder, Colorado

    SciTech Connect (OSTI)

    Arena, L.; Williamson, J.

    2013-11-01

    To determine the most cost-effective methods of improving buildings, accurate analysis and prediction of the energy use of existing buildings is essential. However, multiple studies confirm that analysis methods tend to over-predict energy use in poorly insulated, leaky homes and thus, the savings associated with improving those homes. In NREL's report titled 'Assessing and Improving the Accuracy of Energy Analysis of Residential Buildings,' researchers propose a method for improving the accuracy of residential energy analysis methods. A key step in this process involves the comparisons of predicted versus metered energy use and savings. In support of this research need, CARB evaluated the retrofit of a multifamily building in Boulder, CO. The updated property is a 37 unit, 2 story apartment complex built in 1950, which underwent renovations in early 2009 to bring it into compliance with Boulder, CO's SmartRegs ordinance. Goals of the study were to: 1) evaluate predicted versus actual savings due to the improvements, 2) identify areas where the modeling assumptions may need to be changed, and 3) determine common changes made by renters that would negatively impact energy savings. In this study, CARB seeks to improve the accuracy of modeling software while assessing retrofit measures to specifically determine which are most effective for large multifamily complexes in the cold climate region. Other issues that were investigated include the effects of improving building efficiency on tenant comfort, the impact on tenant turnover rates, and the potential market barriers for this type of community scale project.

  19. ACTUAL-WASTE TESTING OF ULTRAVIOLET LIGHT TO AUGMENT THE ENHANCED CHEMICAL CLEANING OF SRS SLUDGE

    SciTech Connect (OSTI)

    Martino, C.; King, W.; Ketusky, E.

    2012-07-10

    In support of Savannah River Site (SRS) tank closure efforts, the Savannah River National Laboratory (SRNL) conducted Real Waste Testing (RWT) to evaluate Enhanced Chemical Cleaning (ECC), an alternative to the baseline 8 wt% oxalic acid (OA) chemical cleaning technology for tank sludge heel removal. ECC utilizes a more dilute OA solution (2 wt%) and an oxalate destruction technology using ozonolysis with or without the application of ultraviolet (UV) light. SRNL conducted tests of the ECC process using actual SRS waste material from Tanks 5F and 12H. The previous phase of testing involved testing of all phases of the ECC process (sludge dissolution, OA decomposition, product evaporation, and deposition tank storage) but did not involve the use of UV light in OA decomposition. The new phase of testing documented in this report focused on the use of UV light to assist OA decomposition, but involved only the OA decomposition and deposition tank portions of the process. Compared with the previous testing at analogous conditions without UV light, OA decomposition with the use of UV light generally reduced time required to reach the target of <100 mg/L oxalate. This effect was the most pronounced during the initial part of the decomposition batches, when pH was <4. For the later stages of each OA decomposition batch, the increase in OA decomposition rate with use of the UV light appeared to be minimal. Testing of the deposition tank storage of the ECC product resulted in analogous soluble concentrations regardless of the use or non-use of UV light in the ECC reactor.

  20. STEAM REFORMING TECHNOLOGY DEMONSTRATION FOR THE DESTRUCTION OF ORGANICS ON ACTUAL DOE SAVANNAH RIVER SITE TANK 48H WASTE 9138

    SciTech Connect (OSTI)

    Burket, P

    2009-02-24

    This paper describes the design of the Bench-scale Steam Reformer (BSR); a processing unit for demonstrating steam reforming technology on actual radioactive waste [1]. It describes the operating conditions of the unit used for processing a sample of Savannah River Site (SRS) Tank 48H waste. Finally, it compares the results from processing the actual waste in the BSR to processing simulant waste in the BSR to processing simulant waste in a large pilot scale unit, the Fluidized Bed Steam Reformer (FBSR), operated at Hazen Research Inc. in Golden, CO. The purpose of this work was to prove that the actual waste reacted in the same manner as the simulant waste in order to validate the work performed in the pilot scale unit which could only use simulant waste.

  1. Final Report. LAW Glass Formulation to Support AP-101 Actual Waste Testing, VSL-03R3470-2, Rev. 0

    SciTech Connect (OSTI)

    Muller, I. S.; Pegg, I. L.; Rielley, Elizabeth; Carranza, Isidro; Hight, Kenneth; Lai, Shan-Tao T.; Mooers, Cavin; Bazemore, Gina; Cecil, Richard; Kruger, Albert A.

    2015-06-22

    The main objective of the work was to develop and select a glass formulation for vitrification testing of the actual waste sample of LAW AP-101 at Battelle - Pacific Northwest Division (PNWD). Other objectives of the work included preparation and characterization of glasses to demonstrate compliance with contract and processing requirements, evaluation of the ability to achieve waste loading requirements, testing to demonstrate compatibility of the glass melts with melter materials of construction, comparison of the properties of simulant and actual waste glasses, and identification of glass formulation issues with respect to contract specifications and processing requirements.

  2. Ion exchange removal of cesium from simulated and actual supernate from Hanford tanks 241-SY-101 and 241-SY-103

    SciTech Connect (OSTI)

    Brown, G.N.; Bontha, J.R.; Carlson, C.D.

    1995-09-01

    Pacific Northwest Laboratory (PNL), in conjunction with the Process Chemistry and Statistics Section of Westinghouse Hanford Company (WHC), conducted this study as part of the Supernatant Treatment Development Task for the Initial Pretreatment Module (IPM) Applied Engineering Project. The study assesses the performance of the CS-100 ion exchange material for removing cesium from simulated and actual alkaline supernate from Hanford tanks 241-SY-101 and 241-SY-103. The objective of these experiments is to compare the cesium ion exchange loading and elution profiles of actual and simulated wastes. Specific experimental objectives include (1) demonstration of decontamination factors (DF) for cesium removal, 92) verification of simulant performance, (3) investigation of waste/exchanger chemistry, and (4) determination of the radionuclide content of the regenerated CS-100 resin prior to disposal.

  3. ,"Table 1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2006 and Projected 2007 through 2011 " ,"(Thousands of Megawatthours and 2006 Base Year)" ,"Net Energy For Load (Annual)",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"FRCC","MRO (U.S.) ","NPCC (U.S.)

  4. ,"Table 1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2006 and Projected 2008 through 2012 " ,"(Thousands of Megawatthours and 2007 Base Year)",,,,,,,,,,,," " ,"Net Energy For Load (Annual)",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"FRCC","MRO (U.S.)

  5. ,"Table 1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    Jaunary 2010" ,"Next Update: October 2010" ,"Table 1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2008 and Projected 2009 through 2013 " ,"(Thousands of Megawatthours and 2008 Base Year)",,,,,,,,,,,," " ,"Net Energy For Load (Annual)",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid"

  6. ,"Table 1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    . Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2009 and Projected 2010 through 2014" ,"(Thousands of Megawatthours and 2009 Base Year)",,,,,,,,,,,," " ,"Net Energy For Load (Annual)",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"FRCC","MRO (U.S.)

  7. ,"Table 2a. Noncoincident Summer Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    a. Noncoincident Summer Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2006 and Projected 2007 through 2011 " ,"(Megawatts and 2006 Base Year)" ,"Summer Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"FRCC","MRO (U.S.) ","NPCC (U.S.)

  8. ,"Table 2a. Noncoincident Summer Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    a. Noncoincident Summer Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2007 and Projected 2008 through 2012 " ,"(Megawatts and 2007 Base Year)" ,"Summer Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid",,,," " ,"Projected Year Base","Year",,"FRCC","MRO (U.S.)

  9. ,"Table 2a. Noncoincident Summer Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    8" ,"Released: February 2010" ,"Next Update: October 2010" ,"Table 2a. Noncoincident Summer Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2008 and Projected 2009 through 2013 " ,"(Megawatts and 2008 Base Year)" ,"Summer Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid",,,,"

  10. ,"Table 2a. Noncoincident Summer Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    9" ,"Released: December 2010" ,"Next Update: December 2011" ,"Table 2a. Noncoincident Summer Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2009 and Projected 2010 through 2014 " ,"(Megawatts and 2009 Base Year)" ,"Summer Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid",,,,"

  11. ,"Table 2b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2006 and Projected 2007 through 2011 " ,"(Megawatts and 2006 Base Year)" ,"Winter Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"FRCC"," MRO (U.S.) ","NPCC (U.S.)

  12. ,"Table 2b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2007 and Projected 2008 through 2012 " ,"(Megawatts and 2007 Base Year)" ,"Winter Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"FRCC"," MRO (U.S.) ","NPCC (U.S.)

  13. ,"Table 2b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    2b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2008 and Projected 2009 through 2013 " ,"(Megawatts and 2008 Base Year)" ,"Winter Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"FRCC"," MRO (U.S.) ","NPCC (U.S.)

  14. ,"Table 2b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    2b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2009 and Projected 2010 through 2014 " ,"(Megawatts and 2009 Base Year)" ,"Winter Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"FRCC"," MRO (U.S.) ","NPCC (U.S.)

  15. ,"Table 2b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Council Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    5" ,"Released: January 23, 2008" ,"Next Update: October 2007" ,"Table 2b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Council Region, " ,"2005 and Projected 2006 through 2010 " ,"(Megawatts and 2005 Base Year)" ,"Winter Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid" ,"Projected

  16. Technique of estimation of actual strength of a gas pipeline section at its deformation in landslide action zone

    SciTech Connect (OSTI)

    Tcherni, V.P.

    1996-12-31

    The technique is given which permits determination of stress and strain state (SSS) and estimation of actual strength of a section of a buried main gas pipeline (GP) in the case of its deformation in a landslide action zone. The technique is based on the use of three-dimensional coordinates of axial points of the deformed GP section. These coordinates are received by a full-scale survey. The deformed axis of the surveyed GP section is described by the polynomial. The unknown coefficients of the polynomial can be determined from the boundary conditions at points of connection with contiguous undeformed sections as well as by use of minimization methods in mathematical processing of full-scale survey results. The resulting form of GP section`s axis allows one to determine curvatures and, accordingly, bending moments along all the length of the considered section. The influence of soil resistance to longitudinal displacements of a pipeline is used to determine longitudinal forces. Resulting values of bending moments and axial forces as well as the known value of internal pressure are used to analyze all necessary components of an actual SSS of pipeline section and to estimate its strength by elastic analysis.

  17. Next Update: December 2011 Table 1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region,

    U.S. Energy Information Administration (EIA) Indexed Site

    . Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region, 2009 and Projected 2010 through 2014 2009 3,832,180 225,966 213,797 285,625 880,377 997,142 202,301 308,278 718,694 Contiguous U.S. FRCC MRO (U.S.) NPCC (U.S.) RFC SERC SPP TRE WECC (U.S.) 3,969,750 223,174 225,167 291,540 961,436 1,027,470 211,438 310,444 719,081 4,084,175 225,498 229,258 292,816 1,024,183 1,051,645 215,333 316,194 729,248 4,203,875 229,393 240,817 295,623 1,081,320 1,072,124

  18. Next Update: October 2009 Table 1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region,

    U.S. Energy Information Administration (EIA) Indexed Site

    1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region, 2006 and Projected 2008 through 2012 2007 4,012,728 232,405 217,602 301,766 954,700 1,049,298 210,875 307,064 739,018 Contiguous U.S. FRCC MRO (U.S.) NPCC (U.S.) RFC SERC SPP TRE (ERCOT) WECC (U.S.) 4,085,683 242,923 225,058 301,767 973,800 1,073,081 208,532 313,946 746,575 4,149,201 248,996 230,745 305,223 984,000 1,086,304 212,884 319,355 761,694 4,226,516 255,216 239,483 308,534 999,200

  19. Next Update: October 2010 Table 1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region,

    U.S. Energy Information Administration (EIA) Indexed Site

    Jaunary 2010 Next Update: October 2010 Table 1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Region, 2008 and Projected 2009 through 2013 2008 3,989,058 226,874 227,536 297,362 936,201 1,035,390 207,603 312,401 745,691 Contiguous U.S. FRCC MRO (U.S.) NPCC (U.S.) RFC SERC SPP TRE WECC (U.S.) 4,025,705 227,690 233,519 295,883 958,792 1,051,350 207,850 312,205 738,416 4,076,698 228,579 239,702 295,753 967,962 1,067,893 211,343 315,065 750,401

  20. Making appropriate comparisons of estimated and actual costs of reducing SO{sub 2} emissions under Title IV

    SciTech Connect (OSTI)

    Smith, A.E.

    1998-12-31

    A current sentiment within some parts of the environmental policy community is that market-based regulatory approaches such as emissions trading have proven so effective that actual costs will be only a small fraction of what ex ante cost estimation procedures would project. With this line of reasoning, some have dismissed available cost estimates for major proposed new regulations, such as the new PM and ozone NAAQS, as not meaningful for policy decisions. The most commonly used evidence in support of this position is the experience with SO{sub 2} reductions under Title IV of the 1990 Clean Air Act Amendments. In Title IV, a market for emissions allowances has been used to achieve reductions in sulfur dioxides (SO{sub 2}) to ameliorate acid rain. It is commonly asserted today that the cost of achieving the SO{sub 2} emissions reductions has been only one-tenth or less of what Title IV was originally expected to cost. This paper demonstrates that, to the contrary, actual costs for SO{sub 2} reductions remain roughly in line with original estimates associated with Title IV. Erroneous conclusions about Title IV`s costs are due to inappropriate comparisons of a variety of different measures that appear to be comparable only because they are all stated in dollars per ton. Program cost estimates include the total costs of a fully-implemented regulatory program. The very low costs of Title IV that are commonly cited today are neither directly reflective of a fully implemented Title IV, (which is still many years away) nor reflective of all the costs already incurred. Further, a careful review of history finds that the initial cost estimates that many cite were never associated with Title IV. Technically speaking, people are comparing the estimated control costs for the most-costly power plant associated with earlier acid rain regulatory proposals with prices from a market that do not directly reflect total costs.

  1. ,"Table 1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Assessment Area,"

    U.S. Energy Information Administration (EIA) Indexed Site

    1. Net Energy For Load, Actual and Projected by North American Electric Reliability Corporation Assessment Area," ,"1990-2010 Actual, 2011-2015 Projected" ,"(Thousands of Megawatthours)" ,"Interconnection","NERC Regional Assesment Area" ,,,1990,1991,1992,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,"2011E","2012E","2013E","2014E","2015E" ,"Eastern

  2. ACTUAL-WASTE TESTS OF ENHANCED CHEMICAL CLEANING FOR RETRIEVAL OF SRS HLW SLUDGE TANK HEELS AND DECOMPOSITION OF OXALIC ACID

    SciTech Connect (OSTI)

    Martino, C.; King, W.; Ketusky, E.

    2012-01-12

    Savannah River National Laboratory conducted a series of tests on the Enhanced Chemical Cleaning (ECC) process using actual Savannah River Site waste material from Tanks 5F and 12H. Testing involved sludge dissolution with 2 wt% oxalic acid, the decomposition of the oxalates by ozonolysis (with and without the aid of ultraviolet light), the evaporation of water from the product, and tracking the concentrations of key components throughout the process. During ECC actual waste testing, the process was successful in decomposing oxalate to below the target levels without causing substantial physical or chemical changes in the product sludge.

  3. Characterization, Leaching, and Filtration Testing for Bismuth Phosphate Sludge (Group 1) and Bismuth Phosphate Saltcake (Group 2) Actual Waste Sample Composites

    SciTech Connect (OSTI)

    Lumetta, Gregg J.; Buck, Edgar C.; Daniel, Richard C.; Draper, Kathryn; Edwards, Matthew K.; Fiskum, Sandra K.; Hallen, Richard T.; Jagoda, Lynette K.; Jenson, Evan D.; Kozelisky, Anne E.; MacFarlan, Paul J.; Peterson, Reid A.; Shimskey, Rick W.; Sinkov, Sergey I.; Snow, Lanee A.

    2009-02-19

    A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan.() The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. The actual waste-testing program included homogenizing the samples by group, characterizing the solids and aqueous phases, and performing parametric leaching tests. Two of the eight defined groups—bismuth phosphate sludge (Group 1) and bismuth phosphate saltcake (Group 2)—are the subjects of this report. The Group 1 waste was anticipated to be high in phosphorus and was implicitly assumed to be present as BiPO4 (however, results presented here indicate that the phosphate in Group 1 is actually present as amorphous iron(III) phosphate). The Group 2 waste was also anticipated to be high in phosphorus, but because of the relatively low bismuth content and higher aluminum content, it was anticipated that the Group 2 waste would contain a mixture of gibbsite, sodium phosphate, and aluminum phosphate. Thus, the focus of the Group 1 testing was on determining the behavior of P removal during caustic leaching, and the focus of the Group 2 testing was on the removal of both P and Al. The waste-type definition, archived sample conditions, homogenization activities, characterization (physical, chemical, radioisotope, and crystal habit), and caustic leaching behavior as functions of time, temperature, and hydroxide concentration are discussed in this report. Testing was conducted according to TP-RPP-WTP-467.

  4. ,"Table 3a. January Monthly Peak Hour Demand, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    January 2010" ,"Next Update: October 2010" ,"Table 3a. January Monthly Peak Hour Demand, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2008 and Projected 2009 through 2010 " ,"(Megawatts and 2008 Base Year)" ,"Projected Monthly Base","Year","Contiguous U.S.","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid"

  5. ,"Table 3a. January Monthly Peak Hour Demand, Actual and Projected by North American Electric Reliability Council Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    ,"Table 3a. January Monthly Peak Hour Demand, Actual and Projected by North American Electric Reliability Council Region, " ,"1996 through 2003 and Projected 2004 through 2005 " ,"(Megawatts and 2003 Base Year)" ,"Projected Monthly Base","Year","Contiguous U.S.","Eastern Power Grid",,,,,,,,"Texas Power Grid","Western Power Grid"

  6. ,"Table 3a. January Monthly Peak Hour Demand, Actual and Projected by North American Electric Reliability Council Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    3a. January Monthly Peak Hour Demand, Actual and Projected by North American Electric Reliability Council Region, " ,"2005 and Projected 2006 through 2010 " ,"(Megawatts and 2005 Base Year)" ,"Projected Monthly Base","Year","Contiguous U.S.","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid"

  7. ,"Table 3a. January Monthly Peak Hour Demand, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    6" ,"Released: February 7, 2008" ,"Next Update: October 2008" ,"Table 3a. January Monthly Peak Hour Demand, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2006 and Projected 2007 through 2011 " ,"(Megawatts and 2006 Base Year)" ,"Projected Monthly Base","Year","Contiguous U.S.","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid"

  8. ,"Table 3a. January Monthly Peak Hour Demand, Actual and Projected by North American Electric Reliability Corporation Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    7" ,"Released: February 2009" ,"Next Update: October 2009" ,"Table 3a. January Monthly Peak Hour Demand, Actual and Projected by North American Electric Reliability Corporation Region, " ,"2007 and Projected 2008 through 2009 " ,"(Megawatts and 2007 Base Year)" ,"Projected Monthly Base","Year","Contiguous U.S.","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid"

  9. SU-E-T-417: A Method for Predicting and Correcting the Dosimetric Effect of a Radiotherapy Treatment Couch in Actual Treatment Position

    SciTech Connect (OSTI)

    Duan, J; Shen, S; Wu, X; Huang, M; Benhabib, S; Cardan, R; Popple, R; Brezovich, I

    2014-06-01

    Purpose: Although radiation attenuation by the treatment couch can be included in the calculation of radiotherapy dose, difference between planned and actual treatment couch positions can generate significant dose discrepancies. We propose a method to predict and correct the dosimetric effect of the couch in actual treatment position. Methods: The couch transmission factor, T, varies with beam angle, G, couch lateral position, x, and vertical position, y, i.e., T=T(x,y,G). If T(x,y,G) is known for a fixed couch vertical position y=h, the transmission of central-axis beam (CAX) T(x,y,G) can be obtained by T(x,y,G)=T(x{sup +},h,G), where x{sup +}=x-(y-h)tan(G) and G is the angle between the beam and the vertical axis. Similarly, the transmission of any off-CAX point can be obtained using a similar formula. We measured CAX couch transmission at a fixed couch vertical position over the couch lateral motion range for all gantry angles by continuously scanning rotating arc beams. A 2D couch transmission correction matrix can thus be generated from T(x,h,G) for each treatment field for the actual couch position. By applying the transmission correction matrix to the planned field dose, the couch effect can be predicted and corrected. To verify this method, we measured couch transmission T(x, y=10cm, G=225)(225=IEC 135) and compared to that obtained from equivalent T(x{sup +}, y=3cm, G=225) over the range of lateral motion with a step size of 2 cm . Results: The measured couch transmission factors T(x, y=10cm, G=225) are in excellent agreement with those obtained from the equivalent T(x{sup +}, y=3cm, G=225). The mean difference is 0.004060.00135. Conclusion: The couch transmission correction matrix for any couch position and beam angle can be obtained from one set of scanning measurements at a fixed couch vertical position. The dosimetric effect of the treatment couch can be predicted and corrected by applying the couch transmission correction to the planned dose.

  10. DESTRUCTION OF TETRAPHENYLBORATE IN TANK 48H USING WET AIR OXIDATION BATCH BENCH SCALE AUTOCLAVE TESTING WITH ACTUAL RADIOACTIVE TANK 48H WASTE

    SciTech Connect (OSTI)

    Adu-Wusu, K; Paul Burket, P

    2009-03-31

    Wet Air Oxidation (WAO) is one of the two technologies being considered for the destruction of Tetraphenylborate (TPB) in Tank 48H. Batch bench-scale autoclave testing with radioactive (actual) Tank 48H waste is among the tests required in the WAO Technology Maturation Plan. The goal of the autoclave testing is to validate that the simulant being used for extensive WAO vendor testing adequately represents the Tank 48H waste. The test objective was to demonstrate comparable test results when running simulated waste and real waste under similar test conditions. Specifically: (1) Confirm the TPB destruction efficiency and rate (same reaction times) obtained from comparable simulant tests, (2) Determine the destruction efficiency of other organics including biphenyl, (3) Identify and quantify the reaction byproducts, and (4) Determine off-gas composition. Batch bench-scale stirred autoclave tests were conducted with simulated and actual Tank 48H wastes at SRNL. Experimental conditions were chosen based on continuous-flow pilot-scale simulant testing performed at Siemens Water Technologies Corporation (SWT) in Rothschild, Wisconsin. The following items were demonstrated as a result of this testing. (1) Tetraphenylborate was destroyed to below detection limits during the 1-hour reaction time at 280 C. Destruction efficiency of TPB was > 99.997%. (2) Other organics (TPB associated compounds), except biphenyl, were destroyed to below their respective detection limits. Biphenyl was partially destroyed in the process, mainly due to its propensity to reside in the vapor phase during the WAO reaction. Biphenyl is expected to be removed in the gas phase during the actual process, which is a continuous-flow system. (3) Reaction byproducts, remnants of MST, and the PUREX sludge, were characterized in this work. Radioactive species, such as Pu, Sr-90 and Cs-137 were quantified in the filtrate and slurry samples. Notably, Cs-137, boron and potassium were shown as soluble as a result of the WAO reaction. (4) Off-gas composition was measured in the resulting gas phase from the reaction. Benzene and hydrogen were formed during the reaction, but they were reasonably low in the off-gas at 0.096 and 0.0063 vol% respectively. Considering the consistency in replicating similar test results with simulated waste and Tank 48H waste under similar test conditions, the results confirm the validity of the simulant for other WAO test conditions.

  11. Next Update: December 2011 Table 2a. Noncoincident Summer Peak Load, Actual and Projected by North American Electric Reliability Corporation Region,

    U.S. Energy Information Administration (EIA) Indexed Site

    Released: December 2010 Next Update: December 2011 Table 2a. Noncoincident Summer Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, 2009 and Projected 2010 through 2014 (Megawatts and 2009 Base Year) 2009 725,958 46,550 37,963 55,944 161,241 191,032 41,465 63,518 128,245 Contiguou s U.S. FRCC MRO (U.S.) NPCC (U.S.) RFC SERC SPP TRE WECC (U.S.) 772,089 46,006 42,240 60,215 177,688 201,350 43,395 63,810 137,385 785,069 46,124 42,733 60,820 181,867 205,351

  12. Next Update: December 2011 Table 2b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Corporation Region,

    U.S. Energy Information Administration (EIA) Indexed Site

    b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Corporation Region, 2009 and Projected 2010 through 2014 (Megawatts and 2009 Base Year) 2009/2010 668,818 53,022 35,351 44,864 143,827 193,135 32,863 56,191 109,565 Contiguous U.S. FRCC MRO (U.S.) NPCC (U.S.) RFC SERC SPP TRE WECC (U.S.) 639,073 46,235 35,722 46,374 143,040 183,614 31,415 43,823 108,850 646,845 46,821 36,816 46,529 146,591 186,364 33,047 43,823 106,854 657,839 47,558 37,359 46,753

  13. A Fresh Look at Weather Impact on Peak Electricity Demand and Energy Use of Buildings Using 30-Year Actual Weather Data

    SciTech Connect (OSTI)

    Hong, Tianzhen; Chang, Wen-Kuei; Lin, Hung-Wen

    2013-05-01

    Buildings consume more than one third of the world?s total primary energy. Weather plays a unique and significant role as it directly affects the thermal loads and thus energy performance of buildings. The traditional simulated energy performance using Typical Meteorological Year (TMY) weather data represents the building performance for a typical year, but not necessarily the average or typical long-term performance as buildings with different energy systems and designs respond differently to weather changes. Furthermore, the single-year TMY simulations do not provide a range of results that capture yearly variations due to changing weather, which is important for building energy management, and for performing risk assessments of energy efficiency investments. This paper employs large-scale building simulation (a total of 3162 runs) to study the weather impact on peak electricity demand and energy use with the 30-year (1980 to 2009) Actual Meteorological Year (AMY) weather data for three types of office buildings at two design efficiency levels, across all 17 ASHRAE climate zones. The simulated results using the AMY data are compared to those from the TMY3 data to determine and analyze the differences. Besides further demonstration, as done by other studies, that actual weather has a significant impact on both the peak electricity demand and energy use of buildings, the main findings from the current study include: 1) annual weather variation has a greater impact on the peak electricity demand than it does on energy use in buildings; 2) the simulated energy use using the TMY3 weather data is not necessarily representative of the average energy use over a long period, and the TMY3 results can be significantly higher or lower than those from the AMY data; 3) the weather impact is greater for buildings in colder climates than warmer climates; 4) the weather impact on the medium-sized office building was the greatest, followed by the large office and then the small office; and 5) simulated energy savings and peak demand reduction by energy conservation measures using the TMY3 weather data can be significantly underestimated or overestimated. It is crucial to run multi-decade simulations with AMY weather data to fully assess the impact of weather on the long-term performance of buildings, and to evaluate the energy savings potential of energy conservation measures for new and existing buildings from a life cycle perspective.

  14. Discomfort Glare: What Do We Actually Know?

    SciTech Connect (OSTI)

    Clear, Robert

    2012-02-29

    Glare models were reviewed with an eye for missing conditions or inconsistencies. We found ambiguities as to when to use small source versus large source models, and as to what constitutes a glare source in a complex scene. We also found surprisingly little information validating the assumed independence of the factors driving glare. A barrier to progress in glare research is the lack of a standardized dependent measure of glare. We inverted the glare models to predict luminance, and compared model predictions against the 1949 Luckiesh & Guth data that form the basis of many of them. The models perform surprisingly poorly, particularly with regards to the luminance-size relationship and additivity. Evaluating glare in complex scenes may require fundamental changes to form of the glare models.

  15. CCP_FinalActual_2011_11_06.xlsx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    15 TROJAN DECOMMISSIONING (26,485) 1,500 (27,985) 16 WNP-1&3 DECOMMISSIONING 607 448 159 17 Sub-Total (25,878) 1,948 (27,826) 18 Gross Contracted Power...

  16. Meteorological field measurements at potential and actual wind turbine sites

    SciTech Connect (OSTI)

    Renne, D.S.; Sandusky, W.F.; Hadley, D.L.

    1982-09-01

    An overview of experiences gained in a meteorological measurement program conducted at a number of locations around the United States for the purpose of site evaluation for wind energy utilization is provided. The evolution of the measurement program from its inception in 1976 to the present day is discussed. Some of the major accomplishments and areas for improvement are outlined. Some conclusions on research using data from this program are presented.

  17. Dissolution Studies With Pilot Plant and Actual INTEC Calcines

    SciTech Connect (OSTI)

    Herbst, Ronald Scott; Garn, Troy Gerry

    1999-04-01

    The dissolution of Idaho Nuclear Technology and Engineering Center (INTEC) pilot plant calcines was examined to determine solubility of calcine matrix components in acidic media. Two representatives pilot plant calcine types were studied: Zirconia calcine and Zirconia/ Sodium calcine. Dissolution of these calcines was evaluated using lower initial concentrations of nitric acid than used in previous tests to decrease the [H+] concentration in the final solutions. Lower [H+] concentrations contribute to more favorable TRUEX/SREX solvent extraction flowsheet performance. Dissolution and analytical results were also obtained for radioactive calcines produced using high sodium feeds blended with non-radioactive A1(NO3)3 solutions to dilute the sodium concentration and prevent bed agglomeration during the calcination process. Dissolution tests indicated >95 wt. % of the initial calcine mass can be dissolved using the baseline dissolution procedure, with the exception that higher initial nitric acid concentrations are required. The higher initial acid concentration is required for stoichiometric dissolution of the oxides, primarily aluminum oxide. Statistically designed experiments using pilot plant calcine were performed to determine the effect of mixing rate on dissolution efficiency. Mixing rate was determined to provide minimal effects on wt. % dissolution. The acid/calcine ratio and temperature were the predominate variables affecting the wt. % dissolution, a result consistent with previous studies using other similar types of pilot plant calcines.

  18. File:Theoretical vs Actual Data Lesson Plan .pdf | Open Energy...

    Open Energy Info (EERE)

    this file. Metadata This file contains additional information, probably added from the digital camera or scanner used to create or digitize it. If the file has been modified from...

  19. What do the DOE Zero Energy Ready Home Program Specs Actually...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... conditioners, air-source heat pumps, and water-source (i.e., geothermal) heat pumps up to ... In other words, under Revision 07, if a home's heatingcooling system happens to be a ...

  20. CCP_FinalActual_FY_2015_crlPrintArea1

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    PLANNING 6,787 7,948 (1,161) 56 Sub-Total 15,145 18,569 (3,425) 57 Power Services Marketing and Business Support 58 POWER R&D 6,772 5,936 836 59 SALES & SUPPORT 18,293...

  1. Sugars Can Actually Be Good For Your Health (LBNL Science at the Theater)

    ScienceCinema (OSTI)

    Bertozzi, Carolyn

    2011-10-04

    Like peanut M&Ms, all cells are coated with sugars but the functions of these sugar coatings were a mystery until very recently. This presentation will highlight recent fascinating discoveries regarding why cells are coated with sugars, as well as new tools for cancer detection that take advantage of the cells sugar coating. Professor Bertozzis lab focuses on profiling changes in cell surface glycosylation associated with cancer, inflammation and bacterial infection, and exploiting this information for development of diagnostic and therapeutic approaches. In addition, her group develops nanoscience-based technologies for probing cell function and for medical diagnostics.

  2. Analysis of Actual Operating Conditions of an Off-grid Solid Oxide Fuel Cell

    SciTech Connect (OSTI)

    Dennis Witmer; Thomas Johnson; Jack Schmid

    2008-12-31

    Fuel cells have been proposed as ideal replacements for other technologies in remote locations such as Rural Alaska. A number of suppliers have developed systems that might be applicable in these locations, but there are several requirements that must be met before they can be deployed: they must be able to operate on portable fuels, and be able to operate with little operator assistance for long periods of time. This project was intended to demonstrate the operation of a 5 kW fuel cell on propane at a remote site (defined as one without access to grid power, internet, or cell phone, but on the road system). A fuel cell was purchased by the National Park Service for installation in their newly constructed visitor center at Exit Glacier in the Kenai Fjords National Park. The DOE participation in this project as initially scoped was for independent verification of the operation of this demonstration. This project met with mixed success. The fuel cell has operated over 6 seasons at the facility with varying degrees of success, with one very good run of about 1049 hours late in the summer of 2006, but in general the operation has been below expectations. There have been numerous stack failures, the efficiency of electrical generation has been lower than expected, and the field support effort required has been far higher than expected. Based on the results to date, it appears that this technology has not developed to the point where demonstrations in off road sites are justified.

  3. Do we get actual vendor name while we searched with zip code...

    Open Energy Info (EERE)

    let me know? Submitted by SUTHARI on 29 September, 2014 - 08:02 1 answer Points: 0 Hi SUTHARI, we had a bug in the U.S. Utility Rate Database affecting zip codes with leading...

  4. TESTING OF ENHANCED CHEMICAL CLEANING OF SRS ACTUAL WASTE TANK 5F AND TANK 12H SLUDGES

    SciTech Connect (OSTI)

    Martino, C.; King, W.

    2011-08-22

    Forty three of the High Level Waste (HLW) tanks at the Savannah River Site (SRS) have internal structures that hinder removal of the last approximately five thousand gallons of waste sludge solely by mechanical means. Chemical cleaning can be utilized to dissolve the sludge heel with oxalic acid (OA) and pump the material to a separate waste tank in preparation for final disposition. This dissolved sludge material is pH adjusted downstream of the dissolution process, precipitating the sludge components along with sodium oxalate solids. The large quantities of sodium oxalate and other metal oxalates formed impact downstream processes by requiring additional washing during sludge batch preparation and increase the amount of material that must be processed in the tank farm evaporator systems and the Saltstone Processing Facility. Enhanced Chemical Cleaning (ECC) was identified as a potential method for greatly reducing the impact of oxalate additions to the SRS Tank Farms without adding additional components to the waste that would extend processing or increase waste form volumes. In support of Savannah River Site (SRS) tank closure efforts, the Savannah River National Laboratory (SRNL) conducted Real Waste Testing (RWT) to evaluate an alternative to the baseline 8 wt. % OA chemical cleaning technology for tank sludge heel removal. The baseline OA technology results in the addition of significant volumes of oxalate salts to the SRS tank farm and there is insufficient space to accommodate the neutralized streams resulting from the treatment of the multiple remaining waste tanks requiring closure. ECC is a promising alternative to bulk OA cleaning, which utilizes a more dilute OA (nominally 2 wt. % at a pH of around 2) and an oxalate destruction technology. The technology is being adapted by AREVA from their decontamination technology for Nuclear Power Plant secondary side scale removal. This report contains results from the SRNL small scale testing of the ECC process using SRS sludge tank sample material. A Task Technical and Quality Assurance Plan (TTQAP) details the experimental plan as outlined by the Technical Task Request (TTR). The TTR identifies that the data produced by this testing and results included in this report will support the technical baseline with portions having a safety class functional classification. The primary goals for SRNL RWT are as follows: (1) to confirm ECC performance with real tank sludge samples, (2) to determine the impact of ECC on fate of actinides and the other sludge metals, and (3) to determine changes, if any, in solids flow and settling behavior.

  5. ,"Table 1. Net Energy For Load, Actual and Projected by North American Electric Reliability Council Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    3 and Projected 2004 through 2008 " ,"(Thousands of Megawatthours and 2003 Base Year)" ,"Net Energy For Load (Annual)",,"Contiguous U.S. ","Eastern Power Grid",,,,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"ECAR","FRCC","MAAC","MAIN","MAPP (U.S.) ","NPCC (U.S.)

  6. ,"Table 1. Net Energy For Load, Actual and Projected by North American Electric Reliability Council Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    4 and Projected 2005 through 2009 " ,"(Thousands of Megawatthours and 2004 Base Year)" ,"Net Energy For Load (Annual)",,"Contiguous U.S. ","Eastern Power Grid",,,,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"ECAR","FRCC","MAAC","MAIN","MAPP/MRO (U.S.) ","NPCC (U.S.)

  7. ,"Table 1. Net Energy For Load, Actual and Projected by North American Electric Reliability Council Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    2005 and Projected 2006 through 2010 " ,"(Thousands of Megawatthours and 2005 Base Year)" ,"Net Energy For Load (Annual)",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"FRCC","MRO (U.S.) ","NPCC (U.S.) ","RFC","SERC","SPP","ERCOT","WECC (U.S.) "

  8. ,"Table 2a. Noncoincident Summer Peak Load, Actual and Projected by North American Electric Reliability Council Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    3 and Projected 2004 through 2008 " ,"(Megawatts and 2003 Base Year)",,,," " ,"Summer Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"ECAR","FRCC","MAAC","MAIN","MAPP (U.S.) ","NPCC (U.S.)

  9. ,"Table 2a. Noncoincident Summer Peak Load, Actual and Projected by North American Electric Reliability Council Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    4 and Projected 2005 through 2009 " ,"(Megawatts and 2004 Base Year)",,,," " ,"Summer Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"ECAR","FRCC","MAAC","MAIN","MAPP/MRO (U.S.) ","NPCC (U.S.)

  10. ,"Table 2a. Noncoincident Summer Peak Load, Actual and Projected by North American Electric Reliability Council Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    2005 and Projected 2006 through 2010 " ,"(Megawatts and 2005 Base Year)" ,"Summer Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"FRCC","MRO (U.S.) ","NPCC (U.S.) ","RFC","SERC","SPP","ERCOT","WECC (U.S.) "

  11. ,"Table 2b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Council Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    3 and Projected 2004 through 2008 " ,"(Megawatts and 2003 Base Year)" ,"Winter Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"ECAR","FRCC","MAAC","MAIN","MAPP (U.S.) ","NPCC (U.S.) ","SERC","SPP","ERCOT","WECC (U.S.)

  12. ,"Table 2b. Noncoincident Winter Peak Load, Actual and Projected by North American Electric Reliability Council Region, "

    U.S. Energy Information Administration (EIA) Indexed Site

    4 and Projected 2005 through 2009 " ,"(Megawatts and 2004 Base Year)" ,"Winter Noncoincident Peak Load",,"Contiguous U.S. ","Eastern Power Grid",,,,,,,,"Texas Power Grid","Western Power Grid" ,"Projected Year Base","Year",,"ECAR","FRCC","MAAC","MAIN","MAPP/MRO (U.S.) ","NPCC (U.S.) ","SERC","SPP","ERCOT","WECC (U.S.)

  13. Lipopolysaccharide density and structure govern the extent and distance of nanoparticle interaction with actual and model bacterial outer membranes

    SciTech Connect (OSTI)

    Jacobson, Kurt H.; Gunsolus, Ian L.; Kuech, Thomas R.; Troiano, Julianne M.; Melby, Eric S.; Lohse, Samuel E.; Hu, Dehong; Chrisler, William B.; Murphy, Catherine; Orr, Galya; Geiger, Franz M.; Haynes, Christy L.; Pedersen, Joel A.

    2015-07-24

    Design of nanomedicines and nanoparticle-based antimicrobial and antifouling formulations, and assessment of the potential implications of nanoparticle release into the environment require understanding nanoparticle interaction with bacterial surfaces. Here we demonstrate electrostatically driven association of functionalized nanoparticles with lipopolysaccharides of Gram-negative bacterial outer membranes and find that lipopolysaccharide structure influences the extent and location of binding relative to the lipid-solution interface. By manipulating the lipopolysaccharide content in Shewanella oneidensis outer membranes, we observed electrostatically driven interaction of cationic gold nanoparticles with the lipopolysaccharide-containing leaflet. We probed this interaction by quartz crystal microbalance with dissipation monitoring (QCM-D) and second harmonic generation (SHG) using solid-supported lipopolysaccharide-containing bilayers. Association of cationic nanoparticles increased with lipopolysaccharide content, while no association of anionic nanoparticles was observed. The harmonic-dependence of QCM-D measurements suggested that a population of the cationic nanoparticles was held at a distance from the outer leaflet-solution interface of bilayers containing smooth lipopolysaccharides (those bearing a long O-polysaccharide). Additionally, smooth lipopolysaccharides held the bulk of the associated cationic particles outside of the interfacial zone probed by SHG. Our results demonstrate that positively charged nanoparticles are more likely to interact with Gram-negative bacteria than are negatively charged particles, and this interaction occurs primarily through lipopolysaccharides.

  14. Results of fracture mechanics analyses of the Adorer cranes in the device assembly facility using actual, rather than conservative, stress-components

    SciTech Connect (OSTI)

    Dalder, E.N.C.

    1996-12-26

    Fracture mechanics analyses were done on 3 critical locations on the lower flange of the load beam of the Ederer 5 ton and 4 ton cranes in the D.A.F. Facility. This was done to determine appropriate flaw sizes for NDE detection during periodic inspection, and appropriate inspection intervals.

  15. CENTIMETER CONTINUUM OBSERVATIONS OF THE NORTHERN HEAD OF THE HH 80/81/80N JET: REVISING THE ACTUAL DIMENSIONS OF A PARSEC-SCALE JET

    SciTech Connect (OSTI)

    Masque, Josep M.; Estalella, Robert; Girart, Josep M.; Rodriguez, Luis F.; Beltran, Maria T.

    2012-10-10

    We present 6 and 20 cm Jansky Very Large Array/Very Large Array observations of the northern head of the HH 80/81/80N jet, one of the largest collimated jet systems known so far, aimed to look for knots farther than HH 80N, the northern head of the jet. Aligned with the jet and 10' northeast of HH 80N, we found a radio source not reported before, with a negative spectral index similar to that of HH 80, HH 81, and HH 80N. The fit of a precessing jet model to the knots of the HH 80/81/80N jet, including the new source, shows that the position of this source is close to the jet path resulting from the modeling. If the new source belongs to the HH 80/81/80N jet, its derived size and dynamical age are 18.4 pc and >9 Multiplication-Sign 10{sup 3} yr, respectively. If the jet is symmetric, its southern lobe would expand beyond the cloud edge resulting in an asymmetric appearance of the jet. Based on the updated dynamical age, we speculate on the possibility that the HH 80/81/80N jet triggered the star formation observed in a dense core found ahead of HH 80N, which shows signposts of interaction with the jet. These results indicate that parsec-scale radio jets can play a role in the stability of dense clumps and the regulation of star formation in the molecular cloud.

  16. Stereotactic, Single-Dose Irradiation of Lung Tumors: A Comparison of Absolute Dose and Dose Distribution Between Pencil Beam and Monte Carlo Algorithms Based on Actual Patient CT Scans

    SciTech Connect (OSTI)

    Chen Huixiao; Lohr, Frank; Fritz, Peter; Wenz, Frederik; Dobler, Barbara; Lorenz, Friedlieb; Muehlnickel, Werner

    2010-11-01

    Purpose: Dose calculation based on pencil beam (PB) algorithms has its shortcomings predicting dose in tissue heterogeneities. The aim of this study was to compare dose distributions of clinically applied non-intensity-modulated radiotherapy 15-MV plans for stereotactic body radiotherapy between voxel Monte Carlo (XVMC) calculation and PB calculation for lung lesions. Methods and Materials: To validate XVMC, one treatment plan was verified in an inhomogeneous thorax phantom with EDR2 film (Eastman Kodak, Rochester, NY). Both measured and calculated (PB and XVMC) dose distributions were compared regarding profiles and isodoses. Then, 35 lung plans originally created for clinical treatment by PB calculation with the Eclipse planning system (Varian Medical Systems, Palo Alto, CA) were recalculated by XVMC (investigational implementation in PrecisePLAN [Elekta AB, Stockholm, Sweden]). Clinically relevant dose-volume parameters for target and lung tissue were compared and analyzed statistically. Results: The XVMC calculation agreed well with film measurements (<1% difference in lateral profile), whereas the deviation between PB calculation and film measurements was up to +15%. On analysis of 35 clinical cases, the mean dose, minimal dose and coverage dose value for 95% volume of gross tumor volume were 1.14 {+-} 1.72 Gy, 1.68 {+-} 1.47 Gy, and 1.24 {+-} 1.04 Gy lower by XVMC compared with PB, respectively (prescription dose, 30 Gy). The volume covered by the 9 Gy isodose of lung was 2.73% {+-} 3.12% higher when calculated by XVMC compared with PB. The largest differences were observed for small lesions circumferentially encompassed by lung tissue. Conclusions: Pencil beam dose calculation overestimates dose to the tumor and underestimates lung volumes exposed to a given dose consistently for 15-MV photons. The degree of difference between XVMC and PB is tumor size and location dependent. Therefore XVMC calculation is helpful to further optimize treatment planning.

  17. DOE Zero Energy Ready Home

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    a similar study for ENERGY STAR Homes V3. In actual projects the cost impacts for various upgrades will vary. Project location. Specifications and pricing for actual projects ...

  18. Table Definitions, Sources, and Explanatory Notes

    Gasoline and Diesel Fuel Update (EIA)

    actual production or conclusive formation test (drill stem or wire line), or if economic ... actual production or conclusive formation test (drill stem or wire line), or if economic ...

  19. Microsoft Word - SGIG DOE REPORTING GUIDANCE 09202011.doc

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    status reports to assist DOE in its reporting requirements under the Recovery Act. Field Definition Metrics Field Type ACWP Actual Cost of Work Performed The cost actually...

  20. Drop In Fuels: Where the Road Leads

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Therefore, actual outcomes and results may differ materially from what is expressed or forecast in such forward-looking statements. Factors that could cause actual results or ...

  1. Mr. John E. Kieling, Chief Hazardous Waste Bureau

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    there were no actual or potential hazards to human health or the environment due to exposure to hazardous waste or waste constituents. Further assessment of actual or...

  2. 201X EIA-23S Annual Report of Domestic Oil and Gas Reserves,...

    Gasoline and Diesel Fuel Update (EIA)

    ... actual production or conclusive formation test (drill stem or wire line), or if economic ... actual production or conclusive formation test (drill stem or wire line), or if economic ...

  3. Microsoft Word - 2011 EIA-23S Instructions with maps.doc

    Gasoline and Diesel Fuel Update (EIA)

    ... actual production or conclusive formation test (drill stem or wire line), or if economic ... actual production or conclusive formation test (drill stem or wire line), or if economic ...

  4. FORM EIA-23L ANNUAL SURVEY OF DOMESTIC OIL AND GAS RESERVES

    Gasoline and Diesel Fuel Update (EIA)

    ... actual production or conclusive formation test (drill stem or wire line), or if economic ... actual production or conclusive formation test (drill stem or wire line), or if economic ...

  5. Ethan Frome

    Gasoline and Diesel Fuel Update (EIA)

    ... actual production or conclusive formation test (drill stem or wire line), or if economic ... actual production or conclusive formation test (drill stem or wire line), or if economic ...

  6. FY 2016 Financial Overview

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    actual financial results, forecasts of BPA's financial position at the end of the current fiscal year, comparisons of actual financial results to start-of-year budgets and rate...

  7. 2016 Power Rate Schedules and General Rate Schedule Provisions

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    If the actual generation exceeds the Exhibit A amount, the Customer will receive a credit. If the actual generation is less than the Exhibit A amount, the Customer will...

  8. Master Document

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    If the actual generation exceeds the Exhibit A amount, the Customer will receive a credit. If the actual generation is less than the Exhibit A amount, the Customer will...

  9. FY 2003 Generation Audited Accumlated Net Revenues, March 2004

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    3rd Quarter Review Forecast FY 2003 Actual Results 1 FY 2000 PBL Actual Modified Net Revenue 252 252 2 Energy Northwest Debt Service Adjustment for FY 2000 (82) (82) 3 SFAS...

  10. Total DOE/NNSA

    National Nuclear Security Administration (NNSA)

    8 Actuals 2009 Actuals 2010 Actuals 2011 Actuals 2012 Actuals 2013 Actuals 2014 Actuals 2015 Actuals Total DOE/NNSA 4,385 4,151 4,240 4,862 5,154 5,476 7,170 7,593 Total non-NNSA 3,925 4,017 4,005 3,821 3,875 3,974 3,826 3765 Total Facility 8,310 8,168 8,245 8,683 9,029 9,450 10,996 11,358 non-NNSA includes DOE offices and Strategic Parternship Projects (SPP) employees NNSA M&O Employee Reporting

  11. Beamline 5.3.2.2

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    size at sample (FWHM) 25 nm (theoretical), 31 nm actual Scientific applications Photovoltaics, thin films, macromolecular chemistry, geology, cosmological chemistry,...

  12. Role of Geological and Geophysical Data in Modeling a Southwestern...

    Open Energy Info (EERE)

    actual computer time necessary for model calibration was minimal. The conceptually straightforward approach for parameter estimation utilizing existing hydrological, geophysical,...

  13. Atmospheric Radiation Measurement Program Climate Research Facility Operations Quarterly Report January 1–March 31, 2010

    SciTech Connect (OSTI)

    Sisterson, DL

    2010-04-08

    The U.S. Department of Energy (DOE) requires national user facilities to report time-based operating data. The requirements concern the actual hours of operation (ACTUAL); the estimated maximum operation or uptime goal (OPSMAX), which accounts for planned downtime; and the VARIANCE [1 – (ACTUAL/OPSMAX)], which accounts for unplanned downtime.

  14. Residential Energy Consumption Survey (RECS) - Analysis & Projections...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    This rise has occurred while Federal energy efficiency standards were enacted on every major appliance, overall household energy consumption actually decreased from 10.58 quads to ...

  15. Fact Sheet on NCAR Simulations | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    making projections about the future, based not only on computer modeling but actual data collected from a combination of highly sophisticated ships, aircraft and satellite imagery. ...

  16. This Week In Petroleum Printer-Friendly Version

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    ride in product prices. EIA projects that these markets will recover along with the economy, but in different ways. Table 1 summarizes actual and projected annual percentage...

  17. Tax Credits, Rebates & Savings | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Renewable Energy Grant Program The AEA will not actually approve projects; it will issue recommendations to the state legislature, which will make funding decisions. The AEA...

  18. Cost and Performance Baseline for Fossil Energy Plants; Volume...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Cases) X LIST OF ACRONYMS AND ABBREVIATIONS AACE Association for the Advancement of Cost Engineering acfm Actual cubic feet per minute AEO Annual Energy Outlook BACT Best...

  19. PART I - THE SCHEDULE

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    minimum, breakouts for merit, promotion, variable pay, special adjustments, and structure movements for each pay structure showing actual against approved amounts. (2) A list of...

  20. NREL: Energy Systems Integration Facility - Hardware-in-the-Loop...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    tests at full power and actual load levels in real-time simulations to evaluate component and system performance before going to market. For more information, read the...

  1. OSTI, US Dept of Energy, Office of Scientific and Technical Informatio...

    Office of Scientific and Technical Information (OSTI)

    out the person you needed from a listing of multiple names? Actually, searching the internet doesn't make this process any easier. Related Topics: author names, disambiguation,...

  2. American Recovery & Reinvestment Act of 2009 (Recovery Act or...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... not compensable working time: Traveling to or from the actual place where the ... contractors. The Federal Government benefits through an experienced and trained work ...

  3. Slide 1

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... * Calculated from Contractor Timephased SPA Data TYPE 063013 073113 083113 0930... ActualForecast * 12 Month Performance Snapshot * Based on Contractor Timephased SPA and ...

  4. Category:ISGAN Definitions | Open Energy Information

    Open Energy Info (EERE)

    Shift Factor Definition:Load-Serving Entity Definition:Loading Monitor M Definition:Microgrid Controller Definition:Misoperation N Definition:Native Load Definition:Net Actual...

  5. Michael Skelly President Clean Line Energy Partners

    Broader source: Energy.gov (indexed) [DOE]

    on nearly 200 U.S. Power & Utility engagements ... very familiar with Clean Line, its transmission projects and the ... Plan for Energy Efficiency; actual cost for ...

  6. Home Performance Contractor Pro Forma | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Home Performance Contractor Pro Forma, with program HR, assumptions, marketing actuals and costs, and more, as posted on the U.S. Department of Energy's Better Buildings ...

  7. Table Definitions, Sources, and Explanatory Notes

    Gasoline and Diesel Fuel Update (EIA)

    ... Reservoirs are considered proved if economic producibility is supported by actual production or conclusive formation test (drill stem or wire line), or if economic producibility is ...

  8. Table Definitions, Sources, and Explanatory Notes

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    Reservoirs are considered proved if economic producibility is supported by actual production or conclusive formation test (drill stem or wire line), or if economic producibility is ...

  9. DOE-SEEO-OE0000223 OFFICE OF ELECTRICITY ...

    Office of Scientific and Technical Information (OSTI)

    ... Actual Finish Date Milestone Variance Narrative 1 High capacity cell packaged - no ... The results validated the master control modules ability to monitor SOC and control the ...

  10. SUNSHOT CATALYST PROGRAM

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... the proposed solution including the ability to lead and engage a number of ... versus actual success metrics with an optional overall self-assessment short narrative. ...

  11. Microsoft Word - Short Form CRADA Agreement Boilerplate Approved...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of or first actually reduced to practice in the performance of work under this CRADA. H. "Intellectual Property" means patents, trademarks, copyrights, mask works, Protected CRADA...

  12. Better Buildings Residential Network Data & Evaluation Peer Exchange...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Analysis 9 Custom database tools * Forecast vs. actual-YTD and weekly * Direct mail ... * Workforce Data * Neighborhood and geographic data * Conversion rates 1 0 Forecast vs. ...

  13. Toward Powerful and Compact Terahertz Spectrometers | U.S. DOE...

    Office of Science (SC) Website

    actual double-chirped structure. (D) Spectrum of a terahertz quantum cascade laser comb. ... (through corrugated etching of the laser), a robust comb can be formed since ...

  14. Inspection of Westinghouse Savannah River Company Fees for Managing...

    Energy Savers [EERE]

    BACKGROUND: During the first five years of its contract with the Department of ... Using WSRC's actual performance scores, we estimated that, during the first five years of ...

  15. Lessons Learned from the Photovoltaic Manufacturing Technology...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... yet be poised for actual manufacturing, to enter the field. ... in their technologies in terms of conversion efficiencies ... programmatic decisions and search for ways to minimize ...

  16. Statistical Significance of Data

    U.S. Energy Information Administration (EIA) Indexed Site

    are based on data collected from a randomly chosen subset of the entire commercial building population. One source of the difference between the estimated values and the actual...

  17. BPA-2016-00103-FOIA Request

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to warrant expedited processing because there is: an imminent threat to the life or physical safety of an individual. an urgency to inform the public concerning actual or...

  18. BPA-2014-00361-FOIA Request

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to warrant expedited processing because there is: Dan imminent threat to the life or physical safety of an individual. Dan urgency to inform the public concerning actual or...

  19. BPA-2014-00614-FOIA Request

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to warrant expedited processing because there is: Dan imminent threat to the life or physical safety of an individual. lan urgency to inform the public concerning actual or...

  20. BPA-2014-01173-FOIA Request

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to warrant expedited processing because there is: an imminent threat to the life or physical safety of an individual. an urgency to inform the public concerning actual or...

  1. BPA-2014-01121-FOIA Request

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to warrant expedited processing because there is: Dan imminent threat to the life or physical safety of an individual. Dan urgency to inform the public concerning actual or...

  2. Photo of the Week: Lego Rendition of SLAC National Laboratory...

    Energy Savers [EERE]

    See an actual photo of the SLAC linac. | Photo courtesy of Greg Stewart, SLAC National Accelerator Laboratory. Sarah Gerrity Sarah Gerrity Former Multimedia Editor, Office of ...

  3. This Week In Petroleum Summary Printer-Friendly Version

    Gasoline and Diesel Fuel Update (EIA)

    for the oil industry (Figure 1). Each EIA product is distinct in its purpose, methodology, timeframe, and regional coverage. Some reports are estimates of actual production...

  4. Monthly Performance Report

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Year to Date Actual Awards and Mods Projection FY 2011 FY ... Assessment, and completed the equipment installation. ... a new draft of the overall Data Quality Objectives document ...

  5. TEG On-Vehicle Performance & Model Validation

    Broader source: Energy.gov [DOE]

    Details efforts and results of steady-state and transient models validated with bench, engine dynamometer, and on-vehicle tests to measure actual performance

  6. DOE Announces Webinars on Better Buildings Challenge Education...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... functionality, consolidates previous versions to reduce maintenance, and updates energy prediction algorithms to be in line with actual performance of modern photovoltaic systems. ...

  7. ANL Software Improves Wind Power Forecasting | Department of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    One of the main results from the project is ARGUS PRIMA (PRediction Intelligent MAchine), ... and actual wind power generation, to produce the most accurate power prediction. ...

  8. Recycling Energy Yields Super Savings

    Broader source: Energy.gov [DOE]

    One company is actually recycling energy that has already been used to power manufacturing plants, which is helping facilities cut their energy expenses by up to 20 percent.

  9. Portland HQ Letterhead

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    The QBR will continue with a focus on Bonneville Power Administration's (BPA) finances with a review of current fiscal year actual financial results compared to financial...

  10. http://emdev.apps.em.doe.gov/EMDEV/Pages/groundwaterReport.aspx

    Office of Environmental Management (EM)

    DOE-LM since 2005, long-term monitoring and surveillance with institutional controls. IA plume is actually a collection of several small VOC plumes grouped together for...

  11. HIV virus spread and evolution studied through computer modeling

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and the actual, rapid evolution of the virus (phylogenetics) within each patient's body. "We have developed novel ways of estimating epidemics dynamics such as who infected...

  12. Science On Tap - Phylogenetics and Epidemics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and the actual, rapid evolution of the virus (phylogenetics) within each patient's body. "We have developed novel ways of estimating epidemics dynamics such as who infected...

  13. LOS ALAMOS, N.M., Nov. 19, 2013-Researchers at Los Alamos National...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and the actual, rapid evolution of the virus (phylogenetics) within each patient's body. "We have developed novel ways of estimating epidemics dynamics such as who infected...

  14. From: Henderson, Michael To: Congestion Study Comments; Meyer...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... and will do so again.) See: http:www.iso-ne.comisoexpresswebreportsgrid-treeinterchange-rt-actual- schd and the supporting Excel spreadsheets for interface flow and ...

  15. New Cyanobacteria Metabolic Pathway Critical to Energy Conversion

    SciTech Connect (OSTI)

    2015-12-01

    A little-known metabolic pathway in photosynthetic organisms is actually a major pathway for converting carbon dioxide to biofuels and bioproducts.

  16. Advance Patent Waiver W(A)2011-034 | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    This document waives certain patent rights the Department of Energy (DOE) has to inventions conceived or first actually reduced to practice by DOW CHEMICAL COMPANY under agreement ...

  17. 150122 Traxys DOE RFI Comments

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    in the sale and introduction to market of the ... have actual transactional data on how, when and where the ... the domestic uranium mining, conversion and enrichment ...

  18. Peak Underground Working Natural Gas Storage Capacity

    Gasoline and Diesel Fuel Update (EIA)

    of capacity that may understate the amount that can actually be stored. Working Gas Design Capacity: This measure estimates a natural gas facility's working gas capacity, as...

  19. Systems for Electrical Power from Coproduced and Low Temperature...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    on Geothermal Reservoir Engineering Stanford University ... Background: Field History *Initial unit installed in ... Phase2 Optimum Actual Design Ambient Temperature ep 08 ...

  20. Fuel cell stack monitoring and system control

    DOE Patents [OSTI]

    Keskula, Donald H.; Doan, Tien M.; Clingerman, Bruce J.

    2004-02-17

    A control method for monitoring a fuel cell stack in a fuel cell system in which the actual voltage and actual current from the fuel cell stack are monitored. A preestablished relationship between voltage and current over the operating range of the fuel cell is established. A variance value between the actual measured voltage and the expected voltage magnitude for a given actual measured current is calculated and compared with a predetermined allowable variance. An output is generated if the calculated variance value exceeds the predetermined variance. The predetermined voltage-current for the fuel cell is symbolized as a polarization curve at given operating conditions of the fuel cell.

  1. EC Publications

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Operations and maintenance costs for offshore wind plants are projected to be considerably higher than ... variable inflow conditions as would be experienced in actual operation. ...

  2. Inventory of U.S. Greenhouse Gas Emissions and Sinks: 1990-2009...

    National Nuclear Security Administration (NNSA)

    ... Trade Commission (2011); Gosselin, Smith, and Hodge (1984); the Rubber ... of actual installed capacities for 2004 published by Citigroup Smith Barney (2005). ...

  3. P270-PR

    National Nuclear Security Administration (NNSA)

    ... The BUreall of Air Pollution Control (BAPC) requires this infonnalion within 30 days ofthe end of each calendar quarter. The Summary Report typically identifies the actual net ...

  4. Microsoft Word - 03-11-09 Agenda FINAL.doc

    National Nuclear Security Administration (NNSA)

    ... had completed their review of the CAB web site and submitted their draft ... recommendation letter was easier to evaluate when viewing the actual web site printout Mr. ...

  5. Teleseismic-Seismic Monitoring At Valles Caldera - Redondo Geothermal...

    Open Energy Info (EERE)

    Abstract does not describe study in explicit detail, need to obtain actual source material to write exploration activity summary. References Peter M. Roberts, Keiiti Aki,...

  6. EERE Demonstration for Advanced Retro-commissioning Technology...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Image: Actual and model-predicted energy data, overlaid with outside air temperature Advanced machine learning model using Temperature and Time of the week as input parameters ...

  7. SAS Output

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    Margins by North American Electric Reliability Assessment Area, 2004 - 2014, Actual ... Notes: NERC region and reliability assessment area maps are provided on EIA's Electricity ...

  8. This Week In Petroleum Printer-Friendly Version

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Table 1: Actual and Projected Growth Rates for Motor Gasoline and Distillate Fuel Oil Consumption and their Major Economic Drivers (Percent) 2007 2008 2009 2010* 2011*...

  9. Fact Sheet Fact Sheet Fact Sheet Fact Sheet Fact Sheet Fact Sheet

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    scheduled and actual output inside each hour. WIT projects advance the state of the art The Wind Integration Team was designed to help stretch the federal hydro system's...

  10. Summary Notes from 28 May 2008 Generic Technical Issue Discussion...

    Office of Environmental Management (EM)

    clearly. NRC staff also stated that information on the physical configuration of the inventory in the system and any simplifications to the actual configuration that are made...

  11. Lawrence Livermore National Laboratory's Use of Time and Materials...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    through development and application of science and technology to enhance the Nation's ... overhead, general and administrative expenses, and profit) and actual costs for materials. ...

  12. Search for: All records | SciTech Connect

    Office of Scientific and Technical Information (OSTI)

    ... Good agreement with actual performance was obtained by including details such as off-resonant optical pumping. Now benchmarked against experimental data, the simulation is useful ...

  13. Routing performance analysis and optimization within a massively parallel computer

    DOE Patents [OSTI]

    Archer, Charles Jens; Peters, Amanda; Pinnow, Kurt Walter; Swartz, Brent Allen

    2013-04-16

    An apparatus, program product and method optimize the operation of a massively parallel computer system by, in part, receiving actual performance data concerning an application executed by the plurality of interconnected nodes, and analyzing the actual performance data to identify an actual performance pattern. A desired performance pattern may be determined for the application, and an algorithm may be selected from among a plurality of algorithms stored within a memory, the algorithm being configured to achieve the desired performance pattern based on the actual performance data.

  14. Causal Analysis of the Inadvertent Contact with an Uncontrolled...

    Office of Scientific and Technical Information (OSTI)

    Causal Analysis of the Inadvertent Contact with an Uncontrolled Electrical Hazardous ... given to the wrong issues during the creation, reviews, verifications, and actual ...

  15. Microsoft Word - KCP FONSI 042913 clean version

    National Nuclear Security Administration (NNSA)

    Because the actual future uses of KCP land and facilities ... KCP would need to comply with all regulatory requirements. ... Missouri Department of Natural Resources, Missouri State ...

  16. U O P J I S W J I U P V U O I

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    ... to production requirements in OPEC. The situation ... Information Administration, Reserves and Natural Gas Division. ... where actual oil prices land in the low to high price ...

  17. Wind Program Budget

    SciTech Connect (OSTI)

    2012-01-06

    On this page, you can learn more about the Program's budget request for this fiscal year as well as actual budgets in previous fiscal years.

  18. Slide 1

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... codenames in advertising, promotion or marketing and any use of Cray Inc. internal ... Any difference in system hardware or software design or configuration may affect actual ...

  19. Untitled

    U.S. Energy Information Administration (EIA) Indexed Site

    position of the fixture affect the actual output of compact fluorescent bulbs, and the quality of the light may differ between compact fluorescents and incandescents....

  20. SAS Output

    U.S. Energy Information Administration (EIA) Indexed Site

    9.B. Winter Net Internal Demand, Capacity Resources, and Capacity Margins by North American Electric Reliability Corporation Assessment Area, 2013 Actual, 2014-2018 Projected Net...

  1. SAS Output

    U.S. Energy Information Administration (EIA) Indexed Site

    8.B. Summer Net Internal Demand, Capacity Resources, and Capacity Margins by North American Electric Reliability Corporation Assessment Area, 2013 Actual, 2014-2018 Projected Net...

  2. Audit Report: IG-0676 | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    February 14, 2005 Department of Energy Contractor Home Office Expenses Our review of five ... andor reimbursements for actual home office expenses that were (1) potentially ...

  3. Interviewee Travel Regulations Scope

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    For interviewees, airfare reimbursement is limited to the lesser of the standard coach airfare or the actual amount paid. The lowest available airfare should be obtained...

  4. Microsoft Word - gra-ugs-program-travel-regs-tr9003.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    permanent duty station, airfare reimbursement is limited to the lesser of the standard coach airfare or the actual amount paid. The lowest available airfare should be obtained...

  5. Primary and Site Energy

    U.S. Energy Information Administration (EIA) Indexed Site

    electricity reflect the amount of energy actually consumed within the building. Site energy data are most useful to building engineers, energy managers, building owners and others...

  6. ARM - Instrument - g-1

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    the means to physically sample the actual clouds. For more information about the Gulfstream-1 Research Aircraft, please see http:www.pnl.govatmosphericprogramsrafg1.stm....

  7. Part II: Section B - Supplies, Services, and Costs

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Actual construction management fee available will be established through negotiation of ... Contractor's team that are: (1) small business(es); (2) Protg firms as part of an ...

  8. Fact #797: September 16, 2013 Driving Ranges for Electric Vehicles...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    The figure below shows the Environmental Protection Agency (EPA) driving ranges for ... not directly match EPA-stated ranges that were obtained through actual vehicle testing. ...

  9. Completed Projects Table 2015-08-21.xlsx

    Office of Environmental Management (EM)

    Completed Projects 2005-Present Approved Actual Soil and Water Remediation Soil and Water Remediation ANLE-0030 a 28 30 2007 2007 Yes Yes Yes Nuclear Facility Deactivation and...

  10. FuelClinic | Open Energy Information

    Open Energy Info (EERE)

    that you already own, while helping improve road safety, reducing traffic congestion, and saving you money. FuelClinic.com will accurately calculate and track your actual gas...

  11. Estimating Appliance and Home Electronic Energy Use | Department...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and electronic energy use calculator allows you to estimate your annual energy use and cost to operate specific products. The wattage values provided are samples only; actual...

  12. Rail Coal Transportation Rates

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    EIA uses the confidential version of the STB Waybill data, which includes actual revenue for shipments that originate and terminate at specific locations. The STB Waybill...

  13. Energy Efficient Removal of Ozone from Indoor Air

    Office of Scientific and Technical Information (OSTI)

    ... Despite the very promising results of this pilot study, additional tests should be performed before drawing final conclusions about filter performance in actual practice. The ...

  14. Development of the Mathematics of Learning Curve Models for Evaluating...

    Office of Scientific and Technical Information (OSTI)

    The comparison shows that by modeling governor deadband the simulated frequency response can closely align with the actual system response. Authors: Harrison, Thomas J. 1 + Show ...

  15. Microsoft Word - RPP-RPT-47167_R0

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    actual field work to remove tanks. Performing additional work (e.g., characterization, engineering development, work planning) to resolve these unknowns would be expected to...

  16. Research Highlight

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Traditionally, the neutral buoyancy level (NBL) is defined as the cloud top in most early convection schemes. However, the actual cloud top is typically higher than the NBL, ...

  17. Advance Patent Waiver W(A)2009-058 | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    This document waives certain patent rights the Department of Energy (DOE) has to inventions conceived or first actually reduced to practice by SOLAR TURBINES INC under agreement ...

  18. Aeromagnetic Survey At Mt St Helens Area (Towle, 1983) | Open...

    Open Energy Info (EERE)

    structure of Mount St. Helens in more detail. Electrical and electromagnetic methods would be especially useful in determining the actual electrical conductivity of...

  19. zhang-mh-99.PDF

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    The actual measurements contain information of all scales including those that the observational network cannot resolve. Thus, it is not always appropriate to directly use...

  20. Table Definitions, Sources, and Explanatory Notes

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    if economic producibility is supported by actual production or conclusive formation test (drill stem or wire line), or if economic producibility is supported by core analyses...

  1. Power Business Line Decision Forums, as of March 14, 2005

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Implementation - Rate Case 6 Renewable Budget Levels (wo rate credit) PFR PFR 7 Calpine Geothermal PFR Forecast Assumption - Rate Case Actual Implementation Cancellation -...

  2. Wind Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Wind Generation - ScheduledActual Balancing Reserves - Deployed Near Real-time Wind Animation Wind Projects under Review Growth Forecast Fact Sheets Working together to address...

  3. CITC ETC Energy Audit

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Audit Recommendations (continued) Pumping system- The existing 2 horsepower ... the pump speed up or down to meet actual pumping demand as the building's heating demand ...

  4. DSO216_Phase_II_Summary_Updates

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Limiting Wind Output to Scheduled Value and Curtailing Schedules to Actual Wind Generation Updated: December 13, 2013 I. PURPOSE The purpose of Dispatcher Standing Order (DSO)...

  5. HSEP Committee Meeting - Transcribed Flip Chart Notes

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    actually are (health, public perception, cleanup, etc.) o Lessons learned from Fukushima Page 3 Emergency Preparedness: Suggestions (cont.) 8. Ensure public knows what ...

  6. Date centerdTimes New Roman

    Office of Environmental Management (EM)

    ... Further, the reported annual energy savings were less than the annual payments. Yet, the ... to take measurements of actual energy usage, but inexplicably claimed that they were ...

  7. Flow Boiling Carolyn Coyle, Jacopo Buongiorno, Thomas McKrell

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... in MIT's Reactor Thermal Hydraulics Laboratory. ... and CRUD Actually Improve Safety Margins in LWRs?" ... CASL-U-2015-0068-000 23. CRC Handbook of Chemistry and ...

  8. Released: April 2016

    U.S. Energy Information Administration (EIA) Indexed Site

    A. Summer net internal demand, capacity resources, and capacity margins by North American Electric Reliability Corporation Region" "1999 through 2014 actual, 2015-2016 projected" "megawatts and percent" "Interconnection","NERC Regional Assesment Area","Net Internal Demand (MW)[1] -- Summer" ,,"Actual",,,,,,,,,,,,,,,,,,,,,,,,,,"Projected"

  9. ,"Table 2. Noncoincident Peak Load, by North American Electric Reliability Corporation Assessment Area,"

    U.S. Energy Information Administration (EIA) Indexed Site

    2. Noncoincident Peak Load, by North American Electric Reliability Corporation Assessment Area," ,"1990-2010 Actual, 2011-2015 Projected" ,"(Megawatts)" ,"Interconnection","NERC Regional Assesment Area","Summer" ,,,"Actual",,,,,,,,,,,,,,,,,,,,,"Projected"

  10. ,"Table 4.B Winter Net Internal Demand, Capacity Resources, and Capacity Margins by North American Electric Reliability Corporation Region,"

    U.S. Energy Information Administration (EIA) Indexed Site

    B Winter Net Internal Demand, Capacity Resources, and Capacity Margins by North American Electric Reliability Corporation Region," ,"2001-2010 Actual, 2011-2015 Projected" ,"(Megawatts and Percent)" ,"Interconnection","NERC Regional Assesment Area","Net Internal Demand[1] -- Winter" ,,,"Actual",,,,,,,,,,"Projected"

  11. Slide 1

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    WORK AUTHORIZED (With FeeProfit) - ACTUAL OR PROJECTED ACTUAL TO DATE APR 13 May 13 Jun 13 Jul-Sep 2013 Oct-Dec 2013 Jan-Feb 2014 Mar 14 AT COMPLETION 0001 3600 175,321 80,428...

  12. "Interconnection","NERC Regional Assesment Area","Summer"

    U.S. Energy Information Administration (EIA) Indexed Site

    2. Noncoincident peak load, by North American Electric Reliability Corporation Assessment Area," "1990-2011 actual, 2012-2016 projected" "megawatts" "Interconnection","NERC Regional Assesment Area","Summer" ,,"Actual",,,,,,,,,,,,,,,,,,,,,,,"Projected"

  13. SAS Output

    U.S. Energy Information Administration (EIA) Indexed Site

    . Demand-Side Management Program Annual Effects by Program Category, 2004 through 2012 (Table Discontinued) Energy Efficiency Load Management Total Year Energy Savings (Thousand MWh) Actual Peak Load Reduction (MW) Energy Savings (Thousand MWh) Potential Peak Load Reduction (MW) Actual Peak Load Reduction (MW) Energy Savings (Thousand MWh) Actual Peak Load Reduction (MW) 2004 52,663 14,272 1,966 20,997 9,263 54,629 23,535 2005 59,000 15,394 930 21,259 10,341 59,930 25,735 2006 63,076 16,006 790

  14. SAS Output

    U.S. Energy Information Administration (EIA) Indexed Site

    3. Demand-Side Management Program Incremental Effects by Program Category, 2004 through 2012 (Table Discontinued) Energy Efficiency Load Management Total Year Energy Savings (Thousand MWh) Actual Peak Load Reduction (MW) Energy Savings (Thousand MWh) Potential Peak Load Reduction (MW) Actual Peak Load Reduction (MW) Energy Savings (Thousand MWh) Actual Peak Load Reduction (MW) 2004 4,532 1,727 36 3,064 1,163 4,569 2,890 2005 5,879 1,705 137 2,223 1,162 6,016 2,867 2006 5,394 1,268 99 2,817 1,690

  15. Reflection technique for thermal mapping of semiconductors

    DOE Patents [OSTI]

    Walter, Martin J.

    1989-06-20

    Semiconductors may be optically tested for their temperatures by illuminating them with tunable monochromatic electromagnetic radiation and observing the light reflected off of them. A transition point will occur when the wavelength of the light corresponds with the actual band gap energy of the semiconductor. At the transition point, the image of the semiconductor will appreciably darken as the light is transmitted through it, rather than being reflected off of it. The wavelength of the light at the transition point corresponds to the actual band gap energy and the actual temperature of the semiconductor.

  16. win0203SelUpdates.doc

    Gasoline and Diesel Fuel Update (EIA)

    November 2002 Short-Term Energy Outlook Figure WF1. U.S. Winter Natural Gas Demand (Year-to-Year Percent Change) Table WF1. Illustrative Consumer Prices and Expenditures for Heating Fuels During the Winter 1999-2000 2000-2001 2001-2002 2002-2003 Actual Actual Actual Base Forecast Natural Gas (Midwest) Consumption (mcf) 81.7 99.1 81.3 92.5 Avg. Price ($/mcf) 6.69 9.54 7.34 8.06 Expenditures ($) 546 945 597 746 Heating Oil (Northeast) Consumption (gals) 644 731 584 703 Avg. Price ($/gal) 1.16 1.37

  17. win0203SelUpdates.doc

    Gasoline and Diesel Fuel Update (EIA)

    December 2002 Short-Term Energy Outlook Figure WF1. U.S. Winter Natural Gas Demand (Year-to-Year Percent Change) Table WF1. Illustrative Consumer Prices and Expenditures for Heating Fuels During the Winter 1999-2000 2000-2001 2001-2002 2002-2003 Actual Actual Actual Base Forecast Natural Gas (Midwest) Consumption (mcf) 81.7 99.1 81.3 93.1 Avg. Price ($/mcf) 6.69 9.54 7.34 8.38 Expenditures ($) 546 945 597 780 Heating Oil (Northeast) Consumption (gals) 644 731 584 716 Avg. Price ($/gal) 1.16 1.37

  18. win0203SelUpdates.doc

    Gasoline and Diesel Fuel Update (EIA)

    January 2003 Short-Term Energy Outlook Figure WF1. U.S. Winter Natural Gas Demand (Year-to-Year Percent Change) Table WF1. Illustrative Consumer Prices and Expenditures for Heating Fuels During the Winter 1999-2000 2000-2001 2001-2002 2002-2003 Actual Actual Actual Base Forecast Natural Gas (Midwest) Consumption (mcf) 81.7 99.1 81.3 91.9 Avg. Price ($/mcf) 6.69 9.55 7.33 8.71 Expenditures ($) 546 946 596 800 Heating Oil (Northeast) Consumption (gals) 644 731 584 719 Avg. Price ($/gal) 1.16 1.37

  19. win0203SelUpdates0303.doc

    Gasoline and Diesel Fuel Update (EIA)

    En ergy Outlook -- October 2002 Updated Feb 2003) 1 Winter Fuels Outlook: 2002-2003 Selected Table and Figure Updates Based on the March 2003 Short-Term Energy Outlook Figure WF1. U.S. Winter Natural Gas Demand (Year-to-Year Percent Change) Table WF1. Illustrative Consumer Prices and Expenditures for Heating Fuels During the Winter 1999-2000 2000-2001 2001-2002 2002-2003 Actual Actual Actual Base Forecast Natural Gas (Midwest) Consumption (mcf) 81.7 99.1 81.3 92.1 Avg. Price ($/mcf) 6.69 9.54

  20. Microsoft Word - FCT 2008-final.doc

    Office of Legacy Management (LM)

    ... The apron outfall, midway along the northeast side slope, is not yet affected by grass encroachment. Grass in the rock drains may actually assist in dissipating the energy of site ...

  1. LMS-AMC-S01980-0-0.cdr

    Office of Legacy Management (LM)

    ... mid-May and Amchitka, Alaska, LTS&M Plan U.S. Department of Energy Doc. No. Doc. No. ... ensure that the sample collection reflects actual collection for subsistence consumption. ...

  2. New Whole-House Solutions Case Study: Low-Cost Evaluation of Energy Savings at the Community Scale - Fresno, California

    SciTech Connect (OSTI)

    2014-10-01

    In this project, IBACOS partnered with builder Wathen-Castanos Hybrid Homes to develop a simple and low-cost methodology by which community-scale energy savings can be evaluated based on results at the occupied test house level.Research focused on the builder and trade implementation of a whole-house systems integrated measures package and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

  3. Microsoft Word - summer.doc

    U.S. Energy Information Administration (EIA) Indexed Site

    U. S. 1469 46 Source: AGA Average High Temperature for Six Major Electricity Consuming Cities Actual Normal Diff 516 83 81 2 517 82 81 1 518 87 80 7 519 89 81 8 520 86 81 5 5...

  4. Save Money with Your Very Own Drapes

    Broader source: Energy.gov [DOE]

    So, last winter I decided that I was going to get crafty and make my own blankets as an incentive to keep the thermostat low. It was a fun project, and it actually worked. I needed more blankets,...

  5. Statement from Energy Secretary Samuel W. Bodman on the Passage of H.R. 2776 and H.R. 3221

    Broader source: Energy.gov [DOE]

    "Today the House passed legislation that does little to increase our nation's energy security or reduce greenhouse gas emissions.  In fact, the bills will actually lead to less domestic oil and gas...

  6. Kinard Core Knowledge Middle School

    High Performance Buildings Database

    Fort Collins, CO Located on the outskirts of Fort Collins, the Kinard school has established an impressive benchmark for high performance school buildings. Not only was the school designed with low energy use in mind: it's actually achieving these goals.

  7. Crystal field parameters and energy levels scheme of trivalent...

    Office of Scientific and Technical Information (OSTI)

    have been modeled in the frame of Exchange Charge Model (ECM) of the crystal field theory, taken into account the geometry of systems, with actually site symmetry of the...

  8. State of the States 2010: The Role of Policy in Clean Energy Market Transformation

    Broader source: Energy.gov [DOE]

    This report uses statistical methods to better quantify the connection between a broad array of energy efficiency and renewable energy (collectively known as clean energy) policy and actual reductions in energy use and increases in renewable resource development.

  9. Tracking target objects orbiting earth using satellite-based telescopes

    DOE Patents [OSTI]

    De Vries, Willem H; Olivier, Scot S; Pertica, Alexander J

    2014-10-14

    A system for tracking objects that are in earth orbit via a constellation or network of satellites having imaging devices is provided. An object tracking system includes a ground controller and, for each satellite in the constellation, an onboard controller. The ground controller receives ephemeris information for a target object and directs that ephemeris information be transmitted to the satellites. Each onboard controller receives ephemeris information for a target object, collects images of the target object based on the expected location of the target object at an expected time, identifies actual locations of the target object from the collected images, and identifies a next expected location at a next expected time based on the identified actual locations of the target object. The onboard controller processes the collected image to identify the actual location of the target object and transmits the actual location information to the ground controller.

  10. Fuel Oil Use in Manufacturing

    U.S. Energy Information Administration (EIA) Indexed Site

    logo Return to: Manufacturing Home Page Fuel Oil Facts Oil Price Effect Fuel Switching Actual Fuel Switching Storage Capacity Fuel Oil Use in Manufacturing Why Look at Fuel Oil?...

  11. Search for: All records | SciTech Connect

    Office of Scientific and Technical Information (OSTI)

    ... Cold tests using surrogate pellets and tests on a scale of tens of milligrams using actual used fuel are very promising. The initial tests showed that the process can be performed ...

  12. The General Theory of Relativity - E

    Office of Scientific and Technical Information (OSTI)

    ... Over the 16 months of the actual experiment, the angle of the gyro's axis should have changed by only a few tens of microradians in the plane of its orbit, and a few tenths of a ...

  13. Template:FilePreviewDirectLink | Open Energy Information

    Open Energy Info (EERE)

    link to the actual asset instead of the file page about the asset. Parameters file - e.g. "LEDSGPslides.pdf" Usage Link to an OpenEI page (standard functionality)....

  14. New Energy Basics Site: Check It Out!

    Broader source: Energy.gov [DOE]

    Interested in energy efficiency and renewable energy but a little confused by all the terms? Wondering how the technologies actually work? Maybe you're doing some research or working on a paper and...

  15. Quarterly Review

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    3, 2009 Federal Columbia River Power System (FCRPS) FY 2009 FIRST QUARTER REVIEW Projection for FY 2009 Net Revenues and Reserves A B C D FY 2008 Audited Actuals without FAS 133 &...

  16. BPA-2016-00278-FOIA Request

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of actual ground observations, that measure the ground-to-line heights. Sincerely, James L. Buchal Murphy & Buchal LLP 3425 SE Yamhill Street, Suite 100 Portland, OR 97214 Phone:...

  17. 3 U.S. DEPARTMENT ...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    years. As far as my bonafides are 7 concerned, I was actually was the technical lead author 8 for the EA for the DWPF at high level waste and was also 9 the one that made the...

  18. Email Template

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Use specifics as examples. 6. Too much detail (e.g. citing Presidential directives) 7. ... records are records actually accurate? 8. Need to speak to need to modify RCRA permit a. ...

  19. Home Performance Contractor Pro Forma | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Home Performance Contractor Pro Forma, with program HR, assumptions, marketing actuals and costs, and more, as posted on the U.S. Department of Energy's Better Buildings Neighborhood Program website

  20. Types of Reuse

    Broader source: Energy.gov [DOE]

    The following provides greater detail regarding the types of reuse pursued for LM sites. It should be noted that many actual reuses combine several types of the uses listed below.

  1. DRAFT ADVICE - UNACCEPTABLE PROGRAM IMPACTS UNDER FY 97 BUDGET

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    is in the process of determining whether some of the wastes in the 177 underground storage tanks on site are actually transuranic mixed (TRU-M) wastes, not high-level wastes....

  2. Battery Life Predictive Model

    Energy Science and Technology Software Center (OSTI)

    2009-12-31

    The Software consists of a model used to predict battery capacity fade and resistance growth for arbitrary cycling and temperature profiles. It allows the user to extrapolate from experimental data to predict actual life cycle.

  3. OSTI, US Dept of Energy, Office of Scientific and Technical Informatio...

    Office of Scientific and Technical Information (OSTI)

    Trying to pick out the person you needed from a listing of multiple names? Actually, searching the internet doesn't make this process any easier. Related Topics: author names, ...

  4. Hanford Site Environmental Surveillance Data Report for Calendar Year 2000

    SciTech Connect (OSTI)

    Bisping, Lynn E.

    2001-09-27

    This data report contains the actual raw data used to create tables and summaries in the Hanford Site Environmental Report 2000. This report also includes data from special sampling studies performed in 2000.

  5. --No Title--

    Gasoline and Diesel Fuel Update (EIA)

    Monthly Actual Data Monthly Estimates Weekly Estimates 0 6-Year High (1995-99) 6-Year Low (1995-99) Month 1995 1996 1997 1998 1999 2000 2001 6-Year High (1995-2000) 6-Year Low...

  6. Energy Department Announces New SunShot Investment in Solar Energy...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    "The price of solar panels has fallen dramatically in recent years, but we also need to reduce the cost and time required to actually install them in homes and businesses, and help ...

  7. Class Patent Waiver W(C)2009-001 | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Class Patent Waiver W(C)2009-001 This document waives certain patent rights the Department of Energy (DOE) has to inventions conceived or first actually reduced to practice by ...

  8. Identified Patent Waiver W(I)2010-005 | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Identified Patent Waiver W(I)2010-005 This document waives certain patent rights the Department of Energy (DOE) has to inventions conceived or first actually reduced to practice by ...

  9. Advance Patent Waiver W(A)2010-006 | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Advance Patent Waiver W(A)2010-006 This document waives certain patent rights the Department of Energy (DOE) has to inventions conceived or first actually reduced to practice by ...

  10. Identified Patent Waiver W(I)2010-006 | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Identified Patent Waiver W(I)2010-006 This document waives certain patent rights the Department of Energy (DOE) has to inventions conceived or first actually reduced to practice by ...

  11. Beta calutrons and Y-12 experiments

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    calutrons and Y-12 experiments Among the most enjoyable parts of writing about Y-12's history is the feedback I get from those who actually lived the history I'm trying to capture...

  12. Y-12, submarines, work for others and AVLIS ? Reader response...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    gained from people who actually did the work are extremely valuable in capturing the true history of the times. She lived through the events and has a great recall of the people...

  13. Champions in Science Whose Stars are Still Rising: Profile of...

    Office of Science (SC) Website

    As a sophomore at North Hollywood High School, she took a test and made the school NSB ... should definitely try out," recommends Hu. "I actually thought I flunked the entry test. ...

  14. NNSA to Participate in Aerial Radiation Training Exercise in...

    National Nuclear Security Administration (NNSA)

    in the midst of a potential radiological emergency, and test the knowledge and expertise of these agencies to ensure to a unified response in case of an actual emergency. ...

  15. ~tx410.ptx

    U.S. Energy Information Administration (EIA) Indexed Site

    ... right. 13 I'll legally change my name to sucker. 14 ... I lead a group that basically 18 does power system modeling, ... graduate energy modeling class where we 19 actually have ...

  16. Atmospheric optical calibration system

    DOE Patents [OSTI]

    Hulstrom, Roland L. (Bloomfield, CO); Cannon, Theodore W. (Golden, CO)

    1988-01-01

    An atmospheric optical calibration system is provided to compare actual atmospheric optical conditions to standard atmospheric optical conditions on the basis of aerosol optical depth, relative air mass, and diffuse horizontal skylight to global horizontal photon flux ratio. An indicator can show the extent to which the actual conditions vary from standard conditions. Aerosol scattering and absorption properties, diffuse horizontal skylight to global horizontal photon flux ratio, and precipitable water vapor determined on a real-time basis for optical and pressure measurements are also used to generate a computer spectral model and for correcting actual performance response of a photovoltaic device to standard atmospheric optical condition response on a real-time basis as the device is being tested in actual outdoor conditions.

  17. Class Patent Waiver W(C)2010-007 | Department of Energy

    Office of Environmental Management (EM)

    This document waives certain patent rights the Department of Energy (DOE) has to inventions conceived or first actually reduced to practice by US-CHINA CLEAN ENERGY RESEARCH CENTER ...

  18. I/O Case Studies

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    (>10%) dealing IO related to the tecplot files Frequent OpenSeekClose uses lots of meta time Meta time is 50X of the actual write time Suggestion KEEP the file open saves 90%...

  19. Contract/Project Management

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Management Performance Metrics and Targets 1 ContractProject Management Primary Performance Metrics FY 2011 Target FY 2011 Actual & Forecast FY 2011 Pre- & Post-CAP Comment 1a. ...

  20. U.S. Energy Information Administration (EIA) - Pub

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    economic growth projections in AEO2015 with actual growth rates over the past 30 years. ... 2040-a rate that is 0.4 percentage points slower than the average over the past 30 years. ...

  1. doe eis public scoping meeting.ptx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    it with electricity. We don't have to worry 5 about a gas line under the river. We just prop lines up, 6 whether we go six miles or eight miles or right next door. 7 Actually, in...

  2. Solar Swimming Pool Heaters | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    annual operating costs. Actually, solar pool heating is the most cost-effective use of solar energy in many climates. How They Work Most solar pool heating systems include the...

  3. Comparison and evaluation of turbulence estimation schemes at Rocky Flats Plant

    SciTech Connect (OSTI)

    Bowen, B.M.; Pamp, S.E.

    1993-10-01

    The Rocky Flats Plant (RFP) routinely measures meteorological data to support Air Quality and Emergency Response activities. These data help to characterize the transport and dispersion of actual or potential airborne releases of radionuclides or other hazardous materials.

  4. Mobile Truck Stop Electrification Site Locator

    Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

    of the zip code area instead of the actual location. If you're having difficulty, please contact the technical response team at 800-254-6735. They will be able to assist you. TSE...

  5. Table 2. Nuclear power plant data

    Gasoline and Diesel Fuel Update (EIA)

    Revised: February 3, 2016 (revision) Next release date: Late 2018 Table 2. Nuclear power ... (year) Actual retirement (year) Arkansas Nuclear 1 AR PWR B&W 177 1974 2034 Arkansas ...

  6. CX-010014: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Cleaning of Uncontaminated Steel 3013 and 9975 Parts (Actual and Mockup) CX(s) Applied: B3.6 Date: 01/29/2013 Location(s): South Carolina Offices(s): Savannah River Operations Office

  7. Statement from Energy Secretary Samuel W. Bodman on the Passage...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    reduce greenhouse gas emissions. In fact, the bills will actually lead to less domestic oil and gas production and increased dependence on imported oil." "Because H.R. 2776 and...

  8. Table Definitions, Sources, and Explanatory Notes

    Gasoline and Diesel Fuel Update (EIA)

    and many other products used for their energy or chemical content. F.O.B. Price (Free on Board) The price actually charged at the producing country's port of loading. The...

  9. Infrastructure Security EXCEPTIONAL SERVICE IN THE NATIONAL INTEREST

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Interesting Facts * The thermodynamics that describes the compression, heating, and expansion of the S-CO2 is actually the same as for a jet engine. The difference is that the ...

  10. Cell Senescence: Aging and Cancer

    ScienceCinema (OSTI)

    Campisi, Judith

    2013-05-29

    Scientists have identified a molecular cause behind the ravages of old age and in doing so have also shown how a natural process for fighting cancer in younger persons can actually promote cancer in older individuals.

  11. BPA-2016-00322-FOIA Request

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to w arrant expedited processing because there is: Dan imminent threat to the life or physical safety of an individual. Dan urgency to inform the public concerning actual or...

  12. The Pathway to Energy Security

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Even More Vehicles 0 2 4 6 8 10 12 14 16 18 20 22 1970 1975 1980 1985 1990 1995 2000 2005 2010 2015 2020 2025 Millions of Barrels per Day Domestic Production Actual Projected Light ...

  13. David Hopkinson | netl.doe.gov

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Hopkinson and his team began building a test rig that is designed to measure the permeability of membranes using a slipstream of actual flue gas. The test rig should be...

  14. This Week In Petroleum Printer-Friendly Version

    Gasoline and Diesel Fuel Update (EIA)

    Btu and oil prices rising, there may be many oil and gas customers actually wishing Santa leaves them a lump of coal this Christmas season. Retail Gasoline Prices Rose Last...

  15. Cloudiness Inter-

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of its data will increase the sky area covered. Collection of cloud data is not straightforward, because determination of actual cloud cover is subject to the definition of what...

  16. SuperTruck Initiative Partner Improves Class 8 Truck Efficiency by 115%

    Broader source: Energy.gov [DOE]

    With help from the Energy Department, Class 8 trucks recently hit a record of 12 miles per gallon (mpg) freight efficiency. This milestone is actually a 115% increase in freight efficiency (which...

  17. The

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    issue. The actual cover is not yet available at this time.) This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal...

  18. Table Definitions, Sources, and Explanatory Notes

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    F.O.B. Price (Free on Board) The price actually charged at the producing country's port of loading. The reported price includes deductions for any rebates and discounts or...

  19. Photovoltaic Cell Structure Basics | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Cell Structure Basics Photovoltaic Cell Structure Basics August 19, 2013 - 4:50pm Addthis The actual structural design of a photovoltaic (PV), or solar cell, depends on the ...

  20. A Deep Dive into the Subsea Environment | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    bellow 1000 km 621+ miles depth, never actually left the subs they were in). Subsea oil exploration started at very shallow depths and rapidly has grown to astonishing water...

  1. Quarterly Business Review FY 2009 3rd Quarter Financial Results...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    is based on actual cost estimates with efficiencies built in. The majority of Supply Chain costs come from personnel, then costs to operate the equipment and fleet and special...

  2. ALARA Activities at DOE Submitting ALARA Project Descriptions...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Concerns: Total collective dose for the project *Pre-job collective dose estimate: person-mrem *Actual collective dose measured: person-mrem Effect on dose rates, airborne and...

  3. OSTI, US Dept of Energy, Office of Scientific and Technical Informatio...

    Office of Scientific and Technical Information (OSTI)

    ... This prototype system aims to make searchable the multimedia content, i.e. video and ... the content, i.e. the actual spoken content of an audio or video file is not searchable. ...

  4. Decision support for operations and maintenance (DSOM) system

    DOE Patents [OSTI]

    Jarrell, Donald B.; Meador, Richard J.; Sisk, Daniel R.; Hatley, Darrel D.; Brown, Daryl R.; Keibel, Gary R.; Gowri, Krishnan; Reyes-Spindola, Jorge F.; Adams, Kevin J.; Yates, Kenneth R.; Eschbach, Elizabeth J.; Stratton, Rex C.

    2006-03-21

    A method for minimizing the life cycle cost of processes such as heating a building. The method utilizes sensors to monitor various pieces of equipment used in the process, for example, boilers, turbines, and the like. The method then performs the steps of identifying a set optimal operating conditions for the process, identifying and measuring parameters necessary to characterize the actual operating condition of the process, validating data generated by measuring those parameters, characterizing the actual condition of the process, identifying an optimal condition corresponding to the actual condition, comparing said optimal condition with the actual condition and identifying variances between the two, and drawing from a set of pre-defined algorithms created using best engineering practices, an explanation of at least one likely source and at least one recommended remedial action for selected variances, and providing said explanation as an output to at least one user.

  5. Search for: All records | SciTech Connect

    Office of Scientific and Technical Information (OSTI)

    ... and yellow lights) or approximately the same as expected (green light). Which light to display for a given energy end use is determined by comparing expected to actual energy ...

  6. Summer in the Arctic | U.S. DOE Office of Science (SC)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Did you know that one of the best places to study global warming is actually in one of the coldest climates on the planet? It's true Climate change and a warming world have far ...

  7. Quality Control Inspector (QCI) Pre-Exam Quiz

    Broader source: Energy.gov [DOE]

    This quiz is in no way representative of, nor related to the content of the actual QCI exam. It can however be used as a training tool in preparation of the exam.

  8. Fuel cell stack monitoring and system control

    DOE Patents [OSTI]

    Keskula, Donald H.; Doan, Tien M.; Clingerman, Bruce J.

    2005-01-25

    A control method for monitoring a fuel cell stack in a fuel cell system in which the actual voltage and actual current from the fuel cell stack are monitored. A preestablished relationship between voltage and current over the operating range of the fuel cell is established. A variance value between the actual measured voltage and the expected voltage magnitude for a given actual measured current is calculated and compared with a predetermined allowable variance. An output is generated if the calculated variance value exceeds the predetermined variance. The predetermined voltage-current for the fuel cell is symbolized as a polarization curve at given operating conditions of the fuel cell. Other polarization curves may be generated and used for fuel cell stack monitoring based on different operating pressures, temperatures, hydrogen quantities.

  9. Design of Integrated Laboratory and Heavy-Duty Emissions Testing...

    Broader source: Energy.gov (indexed) [DOE]

    Both simulated and actual diesel emissions were able to be ... More Documents & Publications Bench-Top Engine System for ... Biodiesel and EGR for Low-Temperature NOx and PM Reductions

  10. U.S. Energy Information Administration (EIA)

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    has actually been cold and dry this year, leading to increased use of natural gas for power generation and a forecast for less hydropower supply this summer, according to...

  11. Greenhouse Gas Emissions Impacts of Liberalizing Trade in Environmenta...

    Open Energy Info (EERE)

    "As part of a suite of activities under the From Bali to Copenhagen project, IISD's work on low-carbon goods has focused on trying to measure the actual potential climate...

  12. Appliance Energy Calculator

    Broader source: Energy.gov [DOE]

    Our appliance and electronic energy use calculator allows you to estimate your annual energy use and cost to operate specific products. The wattage values provided are samples only; actual wattage...

  13. C:\\Work 102004\\2006 Projections\\NV Projections Review 2008 v45...

    National Nuclear Security Administration (NNSA)

    ... Solar projects in Clark County. The biggest gain will come if Nevada can become a center ... due to the calculations in the model and how much of it is predictive of an actual future. ...

  14. Y-12 Public Warning Siren System being replaced, tested this...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    increased reliability and efficiency. The siren tests to be held Sept. 26 ensure that the public, Y-12 employees and the environment would be protected in the event of an actual...

  15. Database Aids Building Owners and Operators in Energy-Efficiency Project Decision Making

    Broader source: Energy.gov [DOE]

    EERE's Buildings Performance Database, launched in June 2013, provides access to empirical data on the actual energy performance, as well as physical and operational characteristics of commercial and residential buildings.

  16. Office of Legacy Management … Post Competition Accountability...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Quarterly Cost Report Funded Activity HPO Plan Cost Adjusted Budget Cost (ABC) Estimated Actual Cost (EAC) Explanation for Differences Mission Travel 129,000 129,000 53,935 The ...

  17. U.S. Department of Energy Categorical Exclusion Determination...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Sales of Five Lamp Types EERE- Buildings Technology Program Nationwide Under this notice of data availability DOE is providing notice that actual sales of four lamp types (i.e. ...

  18. Validating Computer-Designed Proteins for Vaccines

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Computed As strange as it sounds, most vaccines are composed of actual dead viruses and bacteria. The idea is that presenting a dead form of the pathogen will fake your body into...

  19. Natural Gas Weekly Update, Printer-Friendly Version

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    October 26 and 27. The company assessed buy-back charges for deliveries onto its system in excess of 110 percent of the shippers' actual usage on the OFO days. Pacific...

  20. Natural Gas Weekly Update

    Gasoline and Diesel Fuel Update (EIA)

    to shippers who deliver more than 110 percent of their actual usage into the pipeline system. Pacific Gas and Electric Company declared a systemwide stage 2 high-inventory...

  1. Natural Gas Weekly Update, Printer-Friendly Version

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    to shippers who deliver more than 110 percent of their actual usage into the pipeline system. Pacific Gas and Electric Company declared a systemwide stage 2 high-inventory...

  2. Natural Gas Weekly Update, Printer-Friendly Version

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    the OFO customers who delivered more than 110 percent of their actual gas usage into the system would be assessed for charges. Pacific Gas and Electric Company issued a...

  3. Natural Gas Weekly Update

    Gasoline and Diesel Fuel Update (EIA)

    the OFO customers who delivered more than 110 percent of their actual gas usage into the system would be assessed for charges. Pacific Gas and Electric Company issued a...

  4. Help:SubObjects | Open Energy Information

    Open Energy Info (EERE)

    except the subobject is listed too. If this is not included, it might actually be OK, but it's working with it in - so there you have it. You'll notice an ask query is in...

  5. Running Jobs Efficiently

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Optimization Running Jobs Efficiently Running Jobs Efficiently Job Efficiency A job's efficiency is the ratio of its CPU time to the actual time it took to run, i.e., cputime ...

  6. NERSC Helps Researchers Discover a Potential On-Off Switch for...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    "If we wish to ultimately design circuit elements at the molecular scale, we need to understand how the intrinsic properties of a molecule or junction are actually connected to its ...

  7. Radiological Safety Training for Plutonium Facilities

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... The actual weapons were built at Los Alamos, New Mexico, which was known as Project Y. The ... body, it is distributed to various organs, depending on its physical and chemical makeup. ...

  8. UTU-029557 | Open Energy Information

    Open Energy Info (EERE)

    Date 511975 Expire Date Held By Production (HBP) HELD BY PROD-Actual HBP Date 5151984 RoyaltyRate Most Recent Action EFFECTIVE DATE Most Recent Action Date 511975 Location...

  9. EC-Web Project Plan | Department of Energy

    Energy Savers [EERE]

    EC-Web Project Plan EC-Web Project Plan The Electronic Commerce World Wide Web (EC-WEB) Project Plan, from an actual DOE software engineering project, can be used as a template to...

  10. Thermal Gradient Holes At Lightning Dock Geothermal Area (Cunniff...

    Open Energy Info (EERE)

    Basis Report on a phase 2 project for DOE Notes A summary of the geophysical and geotechnical data used to pick drill sites, the actual drilling, and then the results from the...

  11. Natural Gas Weekly Update, Printer-Friendly Version

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    who delivered more than 110 percent of their actual gas usage will be assessed for Buy-Back charges. Pacific Gas and Electric Company, which serves customers in northern...

  12. This Week In Petroleum Printer-Friendly Version

    Gasoline and Diesel Fuel Update (EIA)

    from September 2008 production levels. Saudi Arabia, Kuwait, the United Arab Emirates (UAE), and Qatar accounted for about three-fourths of the 2.6 million bbld of actual...

  13. DOE - Office of Legacy Management -- Utica Drop Forge and Tool...

    Office of Legacy Management (LM)

    No indication that the contractor actually did a substantial amount of work of this nature at the site. NY.39-1 NY.39-3 NY.39-4 Site Disposition: Eliminated - Potential for...

  14. Georgia Hosts Multi-Agency Waste Isolation Pilot Plant Transportation Exercise

    Broader source: Energy.gov [DOE]

    COVINGTON, Ga. – Emergency personnel throughout the U.S. who respond in the event of a potential accident involving radioactive waste shipments take part in mock training scenarios to help them prepare for an actual incident.

  15. State Energy Data System | Open Energy Information

    Open Energy Info (EERE)

    Data System Jump to: navigation, search Name State Energy Data System Data Format CSV Geographic Scope United States TODO: Import actual dataset contents into OpenEI The State...

  16. A

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    range to about 12 bits even though the actual detector AD is 16 bits. The maxi- mum framing rate is limited to about 1 frames by the serial readout of the detector the...

  17. S U

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    ... Natural gas requirements for the Energy Information Administration Short-Term Energy Outlook, ... on where actual oil prices land in the low-to-high price range (Tables 5 and 7). ...

  18. Employee Spotlight: Ali Erdemir | Argonne National Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to learn how to actually do research and adapt a very high-caliber research culture.'" To watch the video, click on the image at right. Ali Erdemir is an Argonne...

  19. NREL: Jobs and Economic Development Impact (JEDI) Models - Methodology

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    design, legal) materials (e.g., wind turbine blades) or other components (e.g., nuts ... the JEDI model applies price deflators to account for changes in actual dollar value. ...

  20. B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Overview

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    The next step is entering the estimated per unit rebate to end-users. This is the actual rebate the utility will pay to the end user. The next column over is the estimated per...

  1. Microsoft Word - Document2

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Imagine a home where occupants' health is so well protected, ... a ZER home including actual data from ultra-low utility ... Big Thanks for Making a Difference On October 23 rd -24 th ...

  2. Gasoline from coal in the state of Illinois: feasibility study. Appendix 1. Design

    SciTech Connect (OSTI)

    Not Available

    1980-01-01

    Appendix 1 includes the overall design philosophy about units in parallel, specifications above actual need, spares maintenance, etc. Most of the report involves engineering work sheets for various equipments. (LTN)

  3. DOE-Supported Education and Training Programs Help Crow Tribe...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Robert Stewart, a Crow Tribe member and core education instructor for the program, helped ... actually built it and it worked," said Stewart. "They were telling each other they are ...

  4. DOE Advanced Manufacturing Office EnPI V3.0 Webinar Transcription

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... So, using the tool and using regression analysis allows you to control for those types of variables and it gives you a more accurate window into the effects of your actual energy ...

  5. EIA-914 Monthly Gas Production Report Methodology

    Gasoline and Diesel Fuel Update (EIA)

    ... T T T m A test close to the actual task of estimating monthly 2005 production calibrated ... For a test month, the prior 6 months of production data were linearly fit and the linear ...

  6. 1

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    or cash equivalents thereof of the types described in section 1(b)(2)(B) of the Davis-Bacon Act), daily and weekly number of hours worked, deductions made, and actual wages paid....

  7. BPA-2010-02087-FOIA Response

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    cost of transmission. They also do not include the application of the Conservation Rate Credit. 3 The actual rate paid by an individual customer will vary according to the shape...

  8. Big Eddy-Knight 500 kV line nears completion with Columbia River...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    mile of line. In the crossing, there are just three towers for 1.2 miles of line with the actual river crossing spanning nine-tenths of a mile. The Oregon suspension tower stands...

  9. Sandia National Laboratories: News: Publications: Lab News

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    its funding in New Mexico, its economic footprint is thought to be much larger than the actual dollars it spends. Economic impact models suggest the effect Sandia has on New...

  10. Notices DEPARTMENT OF ENERGY U.S. Energy Information Administration

    U.S. Energy Information Administration (EIA) Indexed Site

    ... on a weekend or national holiday, the reports are to be filed by the next business day. ... lines (pipelines) D The actual value of the dry natural gas production will ...

  11. Advanced Energy Industries Inc | Open Energy Information

    Open Energy Info (EERE)

    environments to see the impact that these new systems are going to have on the reliability and quality of the power. The grid simulator can actually emulate a distribution...

  12. untitled

    Office of Environmental Management (EM)

    Inventions None As stated The Contractor shall not file or cause to be filed on any invention or discovery conceived or first actually reduced to practice in the course of or...

  13. Better Buildings Alliance Equipment Performance Specifications

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... FY2012 FY2013 FY2014 Milestones & Deliverables (Actual) Q3 (Apr-Jun) Q4 (Jul-Sep) Q1 (Octt-Dec) Legend Summary Q2 (Jan-Mar) FY12 activities focused on development of ...

  14. Atmospheric optical calibration system

    DOE Patents [OSTI]

    Hulstrom, R.L.; Cannon, T.W.

    1988-10-25

    An atmospheric optical calibration system is provided to compare actual atmospheric optical conditions to standard atmospheric optical conditions on the basis of aerosol optical depth, relative air mass, and diffuse horizontal skylight to global horizontal photon flux ratio. An indicator can show the extent to which the actual conditions vary from standard conditions. Aerosol scattering and absorption properties, diffuse horizontal skylight to global horizontal photon flux ratio, and precipitable water vapor determined on a real-time basis for optical and pressure measurements are also used to generate a computer spectral model and for correcting actual performance response of a photovoltaic device to standard atmospheric optical condition response on a real-time basis as the device is being tested in actual outdoor conditions. 7 figs.

  15. Microsoft Word - Defense Science Quarterly - 2july09 - FINAL...

    National Nuclear Security Administration (NNSA)

    ... Figure 7. Histogram of measured (red) and actual (green) density using 150 micron x 150 ... laser power and energy measurements in the US-an achievement of two years of effort. ...

  16. This Week In Petroleum Printer-Friendly Version

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    8, 2008 (Next Release on June 25, 2008) Low Refinery Utilization and High Prices? Refinery utilization was lower than typical in first quarter 2008. Actual first-quarter 2008...

  17. Distributed PV Interconnection Screening Procedures and Online...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... of merchant plants or plants interconnecting to our grid just to sell into the grid. ... And actually maybe just following up on the harmonic issues that you mentioned a question ...

  18. Monthly Financial Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    EOY Forecast Actuals: FYTD 1 Gross Sales (excluding bookout adjustment)

  19. PBL FY 2002 Second Quarter Review Forecast of Generation Accumulated...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Slice true-ups, and actual expense levels. Any variation of these can change the net revenue situation. FY 2002 Forecasted Second Quarter Results 170 (418) FY 2002 Unaudited...

  20. CACA-011667 | Open Energy Information

    Open Energy Info (EERE)

    Surface Manager INYO NF Lessee 1 MAMMOTH-PACIFIC LP Lessee 2 none provided Effective Date 311982 Expire Date Held By Production (HBP) HELD BY PROD-Actual HBP Date 12221990...

  1. NVN-074881 | Open Energy Information

    Open Energy Info (EERE)

    Surface Manager BUREAU OF LAND MGMT Lessee 1 ORNI 15 Lessee 2 none provided Effective Date 1012002 Expire Date Held By Production (HBP) HELD BY PROD-Actual HBP Date 112009...

  2. CACA-011672 | Open Energy Information

    Open Energy Info (EERE)

    provided Surface Manager INYO NF Lessee 1 ORNI 10 LLC Lessee 2 none provided Effective Date 111982 Expire Date Held By Production (HBP) HELD BY PROD-Actual HBP Date 12311998...

  3. CACA-014408 | Open Energy Information

    Open Energy Info (EERE)

    Surface Manager INYO NF Lessee 1 MAMMOTH-PACIFIC LP Lessee 2 none provided Effective Date 7191983 Expire Date Held By Production (HBP) HELD BY PROD-Actual HBP Date 782006...

  4. Microsoft PowerPoint - 1-A-3-Beaudry-LOSIQUE-Brief to Blade Workshop...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Energy Capture Efficiency Tower 2020 LCOE Target FY10 Budget for COE reductions ... Modeled cost of energy to reflect impact of DOE R&D; lower than actual market prices Rotor ...

  5. thesis.dvi

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... and insulated, without overheating, a common problem with constant-wattage heating tapes. ... To compare b to data, however, it must be converted to actual field values, d Fb -F A ...

  6. DOE ZERH Webinar: Ventilation and Filtration Strategies with...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... that extra cavity of aggregate under there for radon-resistant construction techniques. ... The other approach is the supply-only approach, where you're actually bringing in a ...

  7. Drive Less, Save More | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    the vehicle miles travelled per person is actually twice as high as it is in Western Europe and three times higher than in Japan. However, alternatives to using your car have...

  8. Real Time Optimizing Code for Stabilization and Control of Plasma Reactors

    Energy Science and Technology Software Center (OSTI)

    1995-09-25

    LOOP4 is a flexible real-time control code that acquires signals (input variables) from an array of sensors, that computes therefrom the actual state of the reactor system, that compares the actual state to the desired state (a goal), and that commands changes to reactor controls (output, or manipulated variables) in order to minimize the difference between the actual state of the reactor and the desired state. The difference between actual and desired states is quantifiedmore » in terms of a distance metric in the space defined by the sensor measurements. The desired state of the reactor is specified in terms of target values of sensor readings that were obtained previously during development and optimization of a process engineer using conventional techniques.« less

  9. Microsoft Word - BPAOvergenerationReport Final v3.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    could not be displaced. 3. Regional loads were represented by actual loads for 2010, factoring in 0.9 percent projected load growth in 2011 and 1.2 percent load growth in 2012 as...

  10. Assessment of Evaluation, Measurement, and Verification Methods- 2014 BTO Peer Review

    Broader source: Energy.gov [DOE]

    Presenter: Jessica Granderson, Lawrence Berkeley National Laboratory Common approaches to quantify building energy savings often rely on estimates because actual measured approaches are costly and difficult to scale, among other reasons.

  11. Slide 1

    Energy Savers [EERE]

    Decline in Load Growth In 2008 - Statewide load growth was 1.18% 10-year average annual growth rate of energy Recent recession caused a decrease in actual usage from 2008 to 2010 ...

  12. Introduction

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    days of large, heavy, fission bombs, the possibility of dangerous nuclear accidents were minimized by assembling the bomb in the final moments before actual use. Modern nuclear weapons adopted 'sealed pit' designs in which all parts of the fission bomb were placed in their final configuration during assembly. This evolution created more compact, lightweight, and low maintenance nuclear weapons, but these weapons could not accommodate separate handling of internal components before actual use,

  13. Electric Power Annual 2011

    U.S. Energy Information Administration (EIA) Indexed Site

    4.A. Summer net internal demand, capacity resources, and capacity margins by North American Electric Reliability Corporation Region" "1999 through 2011 actual, 2012-2016 projected" "megawatts and percent" "Interconnection","NERC Regional Assesment Area","Net Internal Demand (MW)[1] -- Summer" ,,"Actual",,,,,,,,,,,,,,,,,,,,,,,"Projected"

  14. Google Earth locations of USA and seafloor hydrothermal vents with associated rare earth element data

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Andrew Fowler

    2016-02-10

    Google Earth .kmz files that contain the locations of geothermal wells and thermal springs in the USA, and seafloor hydrothermal vents that have associated rare earth element data. The file does not contain the actual data, the actual data is available through the GDR website in two tier 3 data sets entitled "Compilation of Rare Earth Element Analyses from US Geothermal Fields and Mid Ocean Ridge (MOR) Hydrothermal Vents" and "Rare earth element content of thermal fluids from Surprise Valley, California"

  15. FY 2014 Real Property Data Related to Operations and Maintenance Guidance |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Real Property Data Related to Operations and Maintenance Guidance FY 2014 Real Property Data Related to Operations and Maintenance Guidance PDF icon FY_2014_Data_Related_to_Operations_and_Maintenance_Memorandum.pdf More Documents & Publications FY 2013 Real Property Deferred, Actual, and Required Maintenance Reporting Requirement Guidance for Fiscal Year 2015 Facilities Information Management System Data Validations FY 2012 Real Property Deferred, Actual, and

  16. System and method for identifying, validating, weighing and characterizing moving or stationary vehicles and cargo

    DOE Patents [OSTI]

    Beshears, David L.; Batsell, Stephen G.; Abercrombie, Robert K.; Scudiere, Matthew B.; White, Clifford P.

    2007-12-04

    An asset identification and information infrastructure management (AI3M) device having an automated identification technology system (AIT), a Transportation Coordinators' Automated Information for Movements System II (TC-AIMS II), a weigh-in-motion system (WIM-II), and an Automated Air Load Planning system (AALPS) all in electronic communication for measuring and calculating actual asset characteristics, either statically or in-motion, and further calculating an actual load plan.

  17. Dissipation factor as a predictor of anodic coating performance

    DOE Patents [OSTI]

    Panitz, Janda K. G.

    1995-01-01

    A dissipation factor measurement is used to predict as-anodized fixture performance prior to actual use of the fixture in an etching environment. A dissipation factor measurement of the anodic coating determines its dielectric characteristics and correlates to the performance of the anodic coating in actual use. The ability to predict the performance of the fixture and its anodized coating permits the fixture to be repaired or replaced prior to complete failure.

  18. 50 kW Power Block for Distributed Energy Applications - Energy Innovation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Portal Solar Photovoltaic Solar Photovoltaic Industrial Technologies Industrial Technologies Energy Storage Energy Storage Electricity Transmission Electricity Transmission Find More Like This Return to Search 50 kW Power Block for Distributed Energy Applications National Renewable Energy Laboratory Contact NREL About This Technology Actual prototype Actual prototype Technology Marketing Summary Distributed energy (DE) systems have begun to make a significant impact on energy supply and will

  19. ,"Table 3A.1. January Monthly Peak Hour Demand, by North American Electric Reliability Corporation Assesment Area,"

    U.S. Energy Information Administration (EIA) Indexed Site

    A.1. January Monthly Peak Hour Demand, by North American Electric Reliability Corporation Assesment Area," ,"1996-2010 Actual, 2011-2012 Projected" ,"(Megawatts)" ,"January","NERC Regional Assesment Area" ,,,"Actual",,,,,,,,,,,,,,,"Projected" ,,,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,"2011E","2012E" ,"Eastern

  20. Method and apparatus for controlling supercharge pressure for a turbocharger

    SciTech Connect (OSTI)

    Abo, T.; Veno, T.

    1987-06-16

    A method for controlling supercharge pressure of a turbocharger, is described which comprises the steps of: seeking a basic control amount, BASE, from a look-up table in accordance with an intake air flow rate Qa; determining if an actual supercharge pressure P2 detected is greater than a first predetermined value of supercharge pressure; calculating the deviation P between the first predetermined supercharge pressure and the actual supercharge pressure P2, and also calculating a proportional value portion (PROP=K1 x P) where K1 is a first constant; determining if the actual supercharge pressure P2 is greater than a second predetermined value of supercharge pressure; calculating an integral value portion INT=(K2 x P + INT') when the actual supercharge pressure P2 is greater than the second predetermined value where K2 is a second constant and INT' is a value of INT resulting from a prior calculation, and setting INT to be zero when the actual supercharge pressure P2 is not greater than the second predetermined pressure; calculating a duty value OUT which is a sum of BASE, PROP and INT; and actuating an electromagnetic valve for controlling the supercharge pressure in accordance with the duty value OUT.

  1. Transformer Efficiency Assessment - Okinawa, Japan

    SciTech Connect (OSTI)

    Thomas L. Baldwin; Robert J. Turk; Kurt S. Myers; Jake P. Gentle; Jason W. Bush

    2012-05-01

    The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of key transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturers factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCBs actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

  2. Transformer Efficiency Assessment - Okinawa, Japan

    SciTech Connect (OSTI)

    Thomas L. Baldwin; Robert J. Turk; Kurt S. Myers; Jake P. Gentle; Jason W. Bush

    2012-05-01

    The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

  3. Transformer Efficiency Assessment - Okinawa, Japan

    SciTech Connect (OSTI)

    Thomas L. Baldwin; Robert J. Turk; Kurt S. Myers; Jake P. Gentle; Jason W. Bush

    2012-08-01

    The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

  4. Parameter monitoring compensation system and method

    DOE Patents [OSTI]

    Barkman, William E.; Babelay, Edwin F.; DeMint, Paul D.; Hebble, Thomas L.; Igou, Richard E.; Williams, Richard R.; Klages, Edward J.; Rasnick, William H.

    1995-01-01

    A compensation system for a computer-controlled machining apparatus having a controller and including a cutting tool and a workpiece holder which are movable relative to one another along preprogrammed path during a machining operation utilizes sensors for gathering information at a preselected stage of a machining operation relating to an actual condition. The controller compares the actual condition to a condition which the program presumes to exist at the preselected stage and alters the program in accordance with detected variations between the actual condition and the assumed condition. Such conditions may be related to process parameters, such as a position, dimension or shape of the cutting tool or workpiece or an environmental temperature associated with the machining operation, and such sensors may be a contact or a non-contact type of sensor or a temperature transducer.

  5. Geostellar: Remote Solar Energy Assessments Personalized

    SciTech Connect (OSTI)

    2015-10-01

    Geostellar has produced an online tool that generates a unique solar profile for homeowners to learn about the financial benefits to installing rooftop solar panels on their home. The website incorporates the physical building characteristics of the home, including shading, slope, and orientation of the roof, and applies electricity costs and incentives to determine the best solar energy estimated energy production values against actual installed rooftop photovoltaic systems. The validation conducted by NREL concluded that over three-quarters of Geostellar's potential size estimates are at least as large as the actual installed systems, indicating a correct assessment of roof availability. In addition, 87% of Geostellar's 25-year production estimates are within 90% of the actual PV Watts results.

  6. Factors Impacting Decommissioning Costs - 13576

    SciTech Connect (OSTI)

    Kim, Karen; McGrath, Richard

    2013-07-01

    The Electric Power Research Institute (EPRI) studied United States experience with decommissioning cost estimates and the factors that impact the actual cost of decommissioning projects. This study gathered available estimated and actual decommissioning costs from eight nuclear power plants in the United States to understand the major components of decommissioning costs. Major costs categories for decommissioning a nuclear power plant are removal costs, radioactive waste costs, staffing costs, and other costs. The technical factors that impact the costs were analyzed based on the plants' decommissioning experiences. Detailed cost breakdowns by major projects and other cost categories from actual power plant decommissioning experiences will be presented. Such information will be useful in planning future decommissioning and designing new plants. (authors)

  7. Parameter monitoring compensation system and method

    DOE Patents [OSTI]

    Barkman, W.E.; Babelay, E.F.; DeMint, P.D.; Hebble, T.L.; Igou, R.E.; Williams, R.R.; Klages, E.J.; Rasnick, W.H.

    1995-02-07

    A compensation system is described for a computer-controlled machining apparatus having a controller and including a cutting tool and a workpiece holder which are movable relative to one another along a preprogrammed path during a machining operation. It utilizes sensors for gathering information at a preselected stage of a machining operation relating to an actual condition. The controller compares the actual condition to a condition which the program presumes to exist at the preselected stage and alters the program in accordance with detected variations between the actual condition and the assumed condition. Such conditions may be related to process parameters, such as a position, dimension or shape of the cutting tool or workpiece or an environmental temperature associated with the machining operation, and such sensors may be a contact or a non-contact type of sensor or a temperature transducer. 7 figs.

  8. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure using a laser sensor

    DOE Patents [OSTI]

    Van Berkel, Gary J.; Kertesz, Vilmos

    2012-02-21

    A system and method utilizes distance-measuring equipment including a laser sensor for controlling the collection instrument-to-surface distance during a sample collection process for use, for example, with mass spectrometric detection. The laser sensor is arranged in a fixed positional relationship with the collection instrument, and a signal is generated by way of the laser sensor which corresponds to the actual distance between the laser sensor and the surface. The actual distance between the laser sensor and the surface is compared to a target distance between the laser sensor and the surface when the collection instrument is arranged at a desired distance from the surface for sample collecting purposes, and adjustments are made, if necessary, so that the actual distance approaches the target distance.

  9. U.S. pipelines continue gains into 1996

    SciTech Connect (OSTI)

    True, W.R.

    1996-11-25

    US interstate natural gas, crude oil, and petroleum product pipelines turned in health performances for 1995, continuing impressive efficiency improvements that were evident in 1994. Revenues and incomes earned from operations along with volumes moved are among data annually submitted to FERC and tracked by Oil and Gas Journal year to year in this exclusive report. This year`s report expands coverage of plans for new construction and completed-cost figures by including Canadian activity for the same 12-month period: July 1, 1995, to June 30, 1996. The paper includes data on the following: pipeline revenues, incomes--1995; North American pipeline costs, estimated; US pipeline costs, estimated vs. actual; North American compressor-construction costs; US compressor costs, estimated vs. actual; Canadian pipeline construction costs, actual; US interstate mileage; investment in liquids pipelines; 10 years of land construction costs; to 10 interstate liquids lines; top 10 interstate gas lines; liquids pipeline companies; and gas pipeline companies.

  10. MDS-Plus data acquisition engine

    SciTech Connect (OSTI)

    Flor, G. ); Cazzaro, F.; Fregonese, G.; Stangherlin, S. )

    1990-10-01

    MDS-Plus, a model driven data acquisition system being jointly developed at Istituto Gas Ionizzati, MIT Plasma Fusion Center, and Los Alamos National Laboratory, is based on the concept of an experiment model. The model contains descriptions of experiment data, devices, and actions to be performed. The data acquisition engine, i.e., the part of the system which actually executes the acquisition process, is driven by the contents of the model itself and implemented as a set of independent processes. A scheduler keeps the data acquisition engine in step with a state machine reflecting the operation of the actual experiment; a dispatcher takes care of the appropriate sequencing of the operations associated with each state of the experiment; various servers actually execute actions on behalf of the dispatcher.

  11. Emergency exercise methodology

    SciTech Connect (OSTI)

    Klimczak, C.A.

    1993-03-01

    Competence for proper response to hazardous materials emergencies is enhanced and effectively measured by exercises which test plans and procedures and validate training. Emergency exercises are most effective when realistic criteria is used and a sequence of events is followed. The scenario is developed from pre-determined exercise objectives based on hazard analyses, actual plans and procedures. The scenario should address findings from previous exercises and actual emergencies. Exercise rules establish the extent of play and address contingencies during the exercise. All exercise personnel are assigned roles as players, controllers or evaluators. These participants should receive specialized training in advance. A methodology for writing an emergency exercise plan will be detailed.

  12. Emergency exercise methodology

    SciTech Connect (OSTI)

    Klimczak, C.A.

    1993-01-01

    Competence for proper response to hazardous materials emergencies is enhanced and effectively measured by exercises which test plans and procedures and validate training. Emergency exercises are most effective when realistic criteria is used and a sequence of events is followed. The scenario is developed from pre-determined exercise objectives based on hazard analyses, actual plans and procedures. The scenario should address findings from previous exercises and actual emergencies. Exercise rules establish the extent of play and address contingencies during the exercise. All exercise personnel are assigned roles as players, controllers or evaluators. These participants should receive specialized training in advance. A methodology for writing an emergency exercise plan will be detailed.

  13. Inquiring Minds - Questions About Physics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Charged Objects and Virtual Photons Hello, I am fascinated by the universe of physics, and I have a few questions. Actually, I was wondering about photons. I have come to understand that photons are the force carrying particles for the electromagnetic force. I also understand that they have no mass and can therefore travel at the speed of light. What I was wondering was this: When two electrons come near, why are real photons said to be emitted, but virtual photons are said to be the actual

  14. Next Update: November 2016

    U.S. Energy Information Administration (EIA) Indexed Site

    1. Net Energy for load, actual and projected by North American Electric Reliability Corporation Assessment Area, 1990-2014 actual, 2015-2016 projected thousands of megawatthours Interconnection NERC Regional Assesment Area 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015E 2016E FRCC 142,502 146,903 147,464 153,468 159,861 169,021 173,377 175,557 188,384 188,598 196,561 200,134 211,116 219,021 220,335 226,544 230,115

  15. Electric Power Annual 2011

    U.S. Energy Information Administration (EIA) Indexed Site

    Table 1. Net Energy for load, actual and projected by North American Electric Reliability Corporation Assessment Area, 1990-2011 actual, 2012-2016 projected thousands of megawatthours Interconnection NERC Regional Assesment Area 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012E 2013E 2014E 2015E 2016E FRCC 142,502 146,903 147,464 153,468 159,861 169,021 173,377 175,557 188,384 188,598 196,561 200,134 211,116 219,021 220,335

  16. Creating a Tiny Human Body on a Chip

    ScienceCinema (OSTI)

    Hunsberger, Maren; Soscia, Dave; Moya, Monica

    2016-03-16

    LLNL science communicator Maren Hunsberger takes us "Inside the Lab" to learn about the iChip (In-vitro Chip-based Human Investigational Platform) project at Lawrence Livermore National Laboratory. "One application of the iChip system would be to develop new pharmaceutical drugs," explains Dave Soscia, LLNL postdoc. "When you test in a mouse for example, it's not as close to the human system as you can get. If we can take human cells and put them on devices and actually mimic the structure and function of the organ systems in the human, we can actually replace animal testing and even make a better system for testing pharmaceutical drugs."

  17. Quantifying the Value of CSP with Thermal Energy Storage

    Broader source: Energy.gov [DOE]

    This PowerPoint slide deck was originally presented at the SunShot Concentrating Solar Power Program Review by Paul Denholm and Mark Mehos of NREL on April 23, 2013. Entitled "Quantifying the Value of CSP with Thermal Energy Storage," the presenters seek to answer the question, "What is the addition of TES to a CSP plant actually worth?" Ultimately they conclude that CSP with TES can actually complement other variable generation sources including solar PV and act as an enabling technology to achieve higher overall penetration of renewable energy.

  18. Sparse sampling and reconstruction for electron and scanning probe microscope imaging

    DOE Patents [OSTI]

    Anderson, Hyrum; Helms, Jovana; Wheeler, Jason W.; Larson, Kurt W.; Rohrer, Brandon R.

    2015-07-28

    Systems and methods for conducting electron or scanning probe microscopy are provided herein. In a general embodiment, the systems and methods for conducting electron or scanning probe microscopy with an undersampled data set include: driving an electron beam or probe to scan across a sample and visit a subset of pixel locations of the sample that are randomly or pseudo-randomly designated; determining actual pixel locations on the sample that are visited by the electron beam or probe; and processing data collected by detectors from the visits of the electron beam or probe at the actual pixel locations and recovering a reconstructed image of the sample.

  19. win0203SelUpdates0203.doc

    Gasoline and Diesel Fuel Update (EIA)

    Updated Feb 2003) 1 Winter Fuels Outlook: 2002-2003 Selected Table and Figure Updates Based on the February 2003 Short-Term Energy Outlook Figure WF1. U.S. Winter Natural Gas Demand (Year-to-Year Percent Change) -25% -20% -15% -10% -5% 0% 5% 10% 15% 20% 25% 2000-2001 2001-2002 2002-2003 Residential Commercial Indust. (incl. CHP) Total Projections Table WF1. Illustrative Consumer Prices and Expenditures for Heating Fuels During the Winter 1999-2000 2000-2001 2001-2002 2002-2003 Actual Actual

  20. Nuclear criticality safety aspects of gaseous uranium hexafluoride (UF{sub 6}) in the diffusion cascade

    SciTech Connect (OSTI)

    Huffer, J.E.

    1997-04-01

    This paper determines the nuclear safety of gaseous UF{sub 6} in the current Gaseous Diffusion Cascade and auxiliary systems. The actual plant safety system settings for pressure trip points are used to determine the maximum amount of HF moderation in the process gas, as well as the corresponding atomic number densities. These inputs are used in KENO V.a criticality safety models which are sized to the actual plant equipment. The ENO V.a calculation results confirm nuclear safety of gaseous UF{sub 6} in plant operations..

  1. Benchmarking Buildings to Prioritize Sites for Emissions Analysis

    Broader source: Energy.gov [DOE]

    When actual energy use by building type is known, benchmarking the performance of those buildings to industry averages can help establish those with greatest opportunities for GHG reduction. Energy intensity can be used as a basis for benchmarking by building type and can be calculated using actual energy use, representative buildings, or available average estimates from agency energy records. Energy intensity should be compared to industry averages, such as the Commercial Buildings Energy Consumption Survey (CBECS) or an agency specific metered sample by location.

  2. Reliability and performance of a system-on-a-chip by predictive wear-out based activation of functional components

    DOE Patents [OSTI]

    Cher, Chen-Yong; Coteus, Paul W; Gara, Alan; Kursun, Eren; Paulsen, David P; Schuelke, Brian A; Sheets, II, John E; Tian, Shurong

    2013-10-01

    A processor-implemented method for determining aging of a processing unit in a processor the method comprising: calculating an effective aging profile for the processing unit wherein the effective aging profile quantifies the effects of aging on the processing unit; combining the effective aging profile with process variation data, actual workload data and operating conditions data for the processing unit; and determining aging through an aging sensor of the processing unit using the effective aging profile, the process variation data, the actual workload data, architectural characteristics and redundancy data, and the operating conditions data for the processing unit.

  3. Thermomechanical treatment of alloys

    DOE Patents [OSTI]

    Bates, John F.; Brager, Howard R.; Paxton, Michael M.

    1983-01-01

    An article of an alloy of AISI 316 stainless steel is reduced in size to predetermined dimensions by cold working in repeated steps. Before the last reduction step the article is annealed by heating within a temperature range, specifically between 1010.degree. C. and 1038.degree. C. for a time interval between 90 and 60 seconds depending on the actual temperature. By this treatment the swelling under neutron bombardment by epithermal neutrons is reduced while substantial recrystallization does not occur in actual use for a time interval of at least of the order of 5000 hours.

  4. FY 2014 Q4 Metrics Report 2014-11-06.xlsx

    Energy Savers [EERE]

    Fourth Quarter Overall Root Cause Analysis (RCA)/Corrective Action Plan (CAP) Performance Metrics No. Contract/Project Management Performance Metrics FY 2014 Target FY 2014 Pre- & Post- CAP* Actual Comment 1 Capital Asset Project Success: Complete 90% of capital asset projects at original scope and within 110% of CD-2 TPC. 90% 67% Pre-CAP 76% Post-CAP Based on 3-year rolling period (FY12 to FY14). TPC is Total Project Cost. No. FY 2014 Target FY 2014 4th Qtr Actual 2 95% 89% 3 95% 94% 4 90%

  5. Switching transients in the MFTF yin-yang coils

    SciTech Connect (OSTI)

    Owen, E.W.; Shimer, D.W.

    1982-11-02

    This report is a study of the transients caused by the fast dump of large superconducting coils. Theoretical analysis, computer simulation, and actual measurements are used. Theoretical analysis can only be applied to the simplest of models. In the computer simulations two models are used, one in which the coil is divided into ten segments and another in which a single coil is employed. The circuit breaker that interrupts the current to the power supply, causing a fast dump, is represented by a time and current dependent conductance. Actual measurements are limited to measurements made incidental to the coils' performance tests.

  6. Microsoft PowerPoint - 09 Tulsa RD Willis Update June.ppt

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    used for the Lake constructed in the 1950 ' ' s. In 1989 the s. In 1989 the dam was modified for the installation of Robert D. Willis dam was modified for the installation of Robert D. Willis Power Plant. The plant has two S Power Plant. The plant has two S - - Tube type turbines Tube type turbines which operate generators nominally rated at 4Mwh each. which operate generators nominally rated at 4Mwh each. Actual power production has rarely exceeded 3.6Mwh Actual power production has rarely

  7. Effect of the resonant growth of harmonics on the electron density in capacitively coupled plasma

    SciTech Connect (OSTI)

    Yamazawa, Yohei

    2009-11-09

    The growth of harmonics is known to occur under the condition of plasma series resonance (PSR). In an actual plasma process chamber, the external circuit also affects the PSR. We experimentally demonstrated the resonant growth of the third and fourth harmonics by tuning a variable capacitor attached to the electrode, and investigated the influence of the growth on the electron density. We observed significant increases in electron density as the amplitude of harmonics grows. The result clearly shows that nonlinear electron resonance heating actually takes place.

  8. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure with image analysis

    DOE Patents [OSTI]

    Van Berkel, Gary J.; Kertesz, Vilmos

    2011-08-09

    A system and method utilizes an image analysis approach for controlling the collection instrument-to-surface distance in a sampling system for use, for example, with mass spectrometric detection. Such an approach involves the capturing of an image of the collection instrument or the shadow thereof cast across the surface and the utilization of line average brightness (LAB) techniques to determine the actual distance between the collection instrument and the surface. The actual distance is subsequently compared to a target distance for re-optimization, as necessary, of the collection instrument-to-surface during an automated surface sampling operation.

  9. Contract/Project Management

    Energy Savers [EERE]

    Fourth Quarter Overall Root Cause Analysis (RCA)/Corrective Action Plan (CAP) Performance Metrics 1 Contract/Project Management Performance Metric FY 2013 Target FY 2013 Actual FY 2013 Pre- & Post-CAP* Actual Comment Capital Asset Project Success: Complete 90% of capital asset projects at original scope and within 110% of CD-2 TPC. 90% 83% Construction 84% Cleanup 82% 70% Pre-CAP 84% Post-CAP Based on 3-year rolling period (FY11 to FY13) of 93 projects. TPC is Total Project Cost.

  10. Contract/Project Management

    Energy Savers [EERE]

    Fourth Quarter Overall Contract and Project Management Improvement Performance Metrics and Targets 1 Contract/Project Management Primary Performance Metrics FY 2011 Target FY 2011 Actual FY 2011 Pre- & Post-CAP Actual Comment 1a. Capital Asset Line Item Projects: (Pre-RCA/CAP) Projects completed within 110% of CD-2 TPC. 1b. Capital Asset Line Item Projects: (Post-RCA/CAP) 90% Line Item 84% Line Item 77% Pre-CAP 100% Post-CAP This is based on a 3-year rolling average (FY09 to FY11). TPC is

  11. Dynamic load measurement on an LPG carrier during voyage

    SciTech Connect (OSTI)

    Kamoi, Noriyuki; Taniguchi, Tomokazu; Kiso, Takashi; Kada, Kazuo; Motoi, Tatsuya; Nakamura, Shinichi

    1994-12-31

    There are few actual ship measurement data showing the propriety of the design loads given by classification societies rules or other relevant rules. Therefore, the authors measured acceleration of ship motion and fluctuating loads on tank supports and chocks of a 75,000 m{sup 3} LPG carrier during her voyage. This paper introduces the subject ship and typical measurement results over about 1.3 years. From the analysis of these data, the authors have made clear the amount of frequency of fluctuating loads during actual navigation and ascertained the propriety of the ship`s design base.

  12. Effects of temperature on desiccant catalysis of refrigerant and lubricant decomposition. Final report

    SciTech Connect (OSTI)

    Rohatgi, N.D.T.

    1998-06-01

    Accelerated aging at high temperatures (149 C) for short aging times (28 days) is effective in screening the compatibility of different materials in refrigeration systems. However, in actual applications temperatures are usually lower and operating times much longer. Therefore plots to allow for interpolation or extrapolation of experimental data to actual operating conditions are needed. In the current study, aging of refrigerant/lubricant/desiccant/metal systems was conducted at five different temperatures, and for each temperature at four different aging times. The data collected from this study provided plots relating refrigerant or lubricant decomposition to aging time, aging temperature, and type of desiccant, which can be used for interpolation or extrapolation.

  13. U.S. DEPARTMENT OF ENERGY

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2# SUMMARY REPORT FORM APPROVED (11-84) OMB NO. 1910-1400 1. IDENTIFICATION NUMBER 2. PROGRAM/ PROJECT TITLE 3. REPORTING PERIOD 4. PARTICIPANT NAME AND ADDRESS 5. START DATE 6. COMPLETION DATE 7. FY 8. MONTHS 9. COST STATUS a. $ Expressed in: b. Budget and Reporting No. c. Cost Plan Date d. Actual Costs Prior Years e. Planned Costs Prior Years f. Total Estimated Cost for Contract g. Total Contract Value h. Estimated Subsequent Reporting Period Accrued Costs g. Planned h. Actual i. Variance j.

  14. "Interconnection","NERC Regional Assesment Area"

    U.S. Energy Information Administration (EIA) Indexed Site

    1. Net Energy for load, actual and projected by North American Electric Reliability Corporation Assessment Area," "1990-2011 actual, 2012-2016 projected" "thousands of megawatthours" "Interconnection","NERC Regional Assesment Area" ,,1990,1991,1992,1993,1994,1995,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011,"2012E","2013E","2014E","2015E","2016E" "Eastern

  15. "Interconnection","NERC Regional Assesment Area","Net Internal Demand[1] -- Winter"

    U.S. Energy Information Administration (EIA) Indexed Site

    B Winter net internal demand, capacity resources, and capacity margins by North American Electric Reliability Corporation" "Region, 2001-2011 actual, 2012-2016 projected" "megawatts and percent" "Interconnection","NERC Regional Assesment Area","Net Internal Demand[1] -- Winter" ,,"Actual",,,,,,,,,,,"Projected" ,,"2001/ 2002","2002/ 2003","2003/ 2004","2004/ 2005","2005/

  16. "January","NERC Regional Assesment Area"

    U.S. Energy Information Administration (EIA) Indexed Site

    A.1. January monthly peak hour demand, by North American Electric Reliability Corporation Assesment Area, " "1996-2011 actual, 2012-2013 projected" "megawatts" "January","NERC Regional Assesment Area" ,,"Actual" ,,1996,1997,1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009,2010,2011 "Eastern Interconnection","FRCC",39860,37127,27122,38581,37521,40258,39675,45033,35545,41247,34464,38352,41705,44945,53093,46086

  17. A guide to experimental elementary particle physics literature, 1985--1989

    SciTech Connect (OSTI)

    Alekhin, S.I.; Bazeeva, V.V.; Ezhela, V.V.; Filimonov, B.B.; Lugovsky, S.B.; Nikolaev, A.S.; Petrova, N.L.; Slabospitsky, S.R.; Striganov, S.I.; Stroganov, Y.G.; Shelkovenko, A.N.; Yuschenko, O.P. . Inst. Fiziki Vysokikh Ehnergij); Yost, G.P.; Rittenberg, A.; Armstrong, F.E.; Barnett, R.M.; Simpson, K.H.; Trippe, T.G.; Wagman, G.S.; W

    1990-11-01

    We present an indexed guide to experimental high energy physics literature for the years 1985--1989. No actual data are given, but approximately 3500 papers are indexed by Beam/Target/Momentum, Reaction/Momentum (including the final stare), Final State Particle, and Accelerator/Experiment/ Detector.

  18. Microsoft PowerPoint - BSQ-300.pptx

    Energy Savers [EERE]

    BSQ-300 Entire Selection Range BSQ-300 Allowable Selection Range: FER ≥ 1 BSQ-300 Allowable Speed Range: FER BEP ≥ 1 BSQ-300 CY2012 Actual Fan Selections (295) BSQ-300 Selections covered by size 360 BSQ-300 Selections covered by size 420

  19. Chicagoland Single-Family Housing Characterization

    SciTech Connect (OSTI)

    Spanier, J.; Scheu, R.; Brand, L.; Yang, J.

    2012-06-01

    In this report, the PARR team identifies housing characteristics and energy use for fifteen housing types (groups) in the Chicagoland (Cook County, Illinois) region and specifies measure packages that provide an optimum level of energy savings based on a BEopt analysis. The analysis is based on assessor data and actual energy consumption data on 432,605 houses representing approximately 30% of the population.

  20. Modeling and Field Results from Seismic Stimulation

    SciTech Connect (OSTI)

    Majer, E.; Pride, S.; Lo, W.; Daley, T.; Nakagawa, Seiji; Sposito, Garrison; Roberts, P.

    2006-05-30

    Modeling the effect of seismic stimulation employing Maxwell-Boltzmann theory shows that the important component of stimulation is mechanical rather than fluid pressure effects. Modeling using Biot theory (two phases) shows that the pressure effects diffuse too quickly to be of practical significance. Field data from actual stimulation will be shown to compare to theory.

  1. Superhydrophobic coating (2008 R&D 100 winner)

    ScienceCinema (OSTI)

    Jeff Brinker

    2010-01-08

    A transparent coating that is not just impermeable to water, but actually makes it bounce off a surface to help prevent corrosion, protect electronic and antiquities, or provide a new, more efficient surface to collect pure water. 2008 R&D 100 winner (SAND2008-2215W)

  2. Vanadium hydride deuterium-tritium generator

    DOE Patents [OSTI]

    Christensen, Leslie D.

    1982-01-01

    A pressure controlled vanadium hydride gas generator to provide deuterium-tritium gas in a series of pressure increments. A high pressure chamber filled with vanadium-deuterium-tritium hydride is surrounded by a heater which controls the hydride temperature. The heater is actuated by a power controller which responds to the difference signal between the actual pressure signal and a programmed pressure signal.

  3. Electric Power Annual 2010

    U.S. Energy Information Administration (EIA) Indexed Site

    A. Summer Net Internal Demand, Capacity Resources, and Capacity Margins by North American Electric Reliability Corporation Region, 1999 through 2010" ,"(Megawatts and Percent)" ,"Interconnection","NERC Regional Assesment Area","Net Internal Demand (MW)[1] -- Summer" ,,,"Actual",,,,,,,,,,,,,,,,,,,,,"Projected"

  4. Form EIA-411 for 2007",,"WINTER

    U.S. Energy Information Administration (EIA) Indexed Site

    WINTER" ,"Released: February 2009" ,"Next Update: October 2009" "Table 5j. Winter (FRCC) Historical and Projected Demand and Capacity, Calendar Year 2007 " "Region","FRCC" "Subregion", "Country","U" ,"WINTER",,"Actual","Projected"

  5. NSA AERI Hatch Correction Data Set

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Turner, David

    2012-03-23

    From 2000-2008, the NSA AERI hatch was determined to be indicated as open too frequently. Analysis suggests that the hatch was actually opening and closing properly but that its status was not being correctly reported by the hatch controller to the datastream. An algorithm was written to determine the hatch status from the observed

  6. Strategy Guideline: Quality Management in Existing Homes - Cantilever Floor Example

    SciTech Connect (OSTI)

    Taggart, J.; Sikora, J.; Wiehagen, J.; Wood, A.

    2011-12-01

    This guideline is designed to highlight the QA process that can be applied to any residential building retrofit activity. The cantilevered floor retrofit detailed in this guideline is included only to provide an actual retrofit example to better illustrate the QA activities being presented.

  7. Effect of turbine-operating regime and adjustment of automated control system on stability and critical area of surge tanks at HPP

    SciTech Connect (OSTI)

    Murav'ev, O. A.

    2011-05-15

    Materials of the works of several authors who have investigated the effect of turbine-operating regime on the stability of HPP with surge tanks are presented. Anumber of new results are obtained. Analytical relationships that can be used in stability calculations for a number of coefficients are compared with a large amount of actual data.

  8. Identify Institutional Change Rules for Sustainability

    Broader source: Energy.gov [DOE]

    It is important to analyze formal and informal workplace rules governing the behavior of individuals and organizations to meet a federal agency's institutional change goals for sustainability. It is also important to determine how these rules actually affect people filling different roles in the organization, and how they mesh with the technologies, systems, and processes that constitute tools.

  9. Semisolid Metal Processing Consortium

    SciTech Connect (OSTI)

    Apelian,Diran

    2002-01-10

    Mathematical modeling and simulations of semisolid filling processes remains a critical issue in understanding and optimizing the process. Semisolid slurries are non-Newtonian materials that exhibit complex rheological behavior. There the way these slurries flow in cavities is very different from the way liquid in classical casting fills cavities. Actually filling in semisolid processing is often counter intuitive

  10. Trace metal characterization and speciation in geothermal effluent by multiple scanning anodic stripping voltammetry and atomic absorpotion analysis. Annual progress report

    SciTech Connect (OSTI)

    Kowalski, B R

    1980-01-01

    Only the actual application of the ultratrace metal analysis methods to samples taken from geothermal sites in Washington and Oregon is covered. The in-field sampling equipment constructed for the studies, procedures developed or adapted, and the results obtained on representative samples taken from geothermal sites are described. (MHR)

  11. First big U.S. reactor dismantled: Project may point the way to a huge market, if sufficient waste disposal sites become available

    SciTech Connect (OSTI)

    Soast, A.,

    1994-07-18

    This article is a review of the Ft. St. Vrain decommissioning efforts. The chain of events leading to actual dismantlement is covered. The projected storage of its fuel at INEL is noted, pending the resolution of legal problems, and the disposal of low-level wastes at Hanford is also noted.

  12. Superhydrophobic Coating (2008 R&D 100 Winner)

    ScienceCinema (OSTI)

    Sandia

    2009-09-01

    A transparent coating that is not just impermeable to water, but actually makes it bounce off a surface to help prevent corrosion, protect electronic and antiquities, or provide a new, more efficient surface to collect pure water. 2008 R&D 100 winner (SAND2008-2215W)

  13. Critical Question #2: What are the Best Practices for Ventilation Specific to Multifamily Buildings?

    Broader source: Energy.gov [DOE]

    What is the best practice to address ASHRAE 62.2 Addendum J (multifamily)? Why is exhaust only (with supply in hallway) the current standard practice? Are there options to avoid air exchange with neighbors? How do stack and wind pressures affect ventilation performance in multifamily homes? What systems actually function as intended and can be implemented by builders and contractors?

  14. Building America Webinar: Who's Successfully Doing Deep Energy Retrofits?

    Broader source: Energy.gov [DOE]

    The webinar will focus on specific Building America projects and case studies that highlight real-world examples of deep energy retrofits that are meeting with technical and market success. Presenters will focus on technical strategies, modeled and actual performance results, and project costs.

  15. Thermal Modeling of NUHOMS HSM-15 and HSM-1 Storage Modules at Calvert Cliffs Nuclear Power Station ISFSI

    SciTech Connect (OSTI)

    Suffield, Sarah R.; Fort, James A.; Adkins, Harold E.; Cuta, Judith M.; Collins, Brian A.; Siciliano, Edward R.

    2012-10-01

    As part of the Used Fuel Disposition Campaign of the Department of Energy (DOE), visual inspections and temperature measurements were performed on two storage modules in the Calvert Cliffs Nuclear Power Station’s Independent Spent Fuel Storage Installation (ISFSI). Detailed thermal models models were developed to obtain realistic temperature predictions for actual storage systems, in contrast to conservative and bounding design basis calculations.

  16. Summaries of FY 1980 research in the chemical sciences

    SciTech Connect (OSTI)

    1980-09-01

    Brief summaries are given of research programs being pursued by DOE laboratories and offsite facilities in the fields of photochemical and radiation sciences, chemical physics, atomic physics, chemical energy, separations, analysis, and chemical engineering sciences. No actual data is given. Indexes of topics, offsite institutions, and investigators are included. (DLC)

  17. Synchronous Phasor-like Measurements

    SciTech Connect (OSTI)

    Kirkham, Harold; Dagle, Jeffery E.

    2014-02-14

    Phasor measurement units struggle to make acceptable estimates of frequency and rate of change of frequency. The most important cause of the problem is that the quantity being measured is not actually a phasor. The paper substitutes a different equation for the phasor equatin, and obtains its solution by curve-fitting.

  18. CX-009074: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Cleaning of Uncontaminated Steel 3013 and 9975 Parts (actual and mockup) in FabLab RBA and D0115 CX(s) Applied: B3.6 Date: 07/16/2012 Location(s): South Carolina Offices(s): Savannah River Operations Office

  19. A ton-scale bolometric detector for the search for neutrinoless double beta decay

    SciTech Connect (OSTI)

    Pedretti, M. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States)

    2009-12-16

    After an introduction on neutrinoless double beta decay physics, a description of CUORE and CUORICINO experiments, detectors and results are reported. The actual efforts and next steps of the CUORE Project, required to probe the inverted hierarchy region of the neutrino effective Majorana mass, are also described.

  20. Free piston stirling engines

    SciTech Connect (OSTI)

    Walker, C.

    1985-01-01

    This book presents a basic introduction to free piston Stirling engine technology through a review of specialized background material. It also includes information based on actual construction and operation experience with these machines, as well as theoretical and analytical insights into free piston Stirling engine technology.

  1. Vertical ground heat exchanger borehole grouting: Field application studies and in-situ thermal performance testing. Final report

    SciTech Connect (OSTI)

    Smith, M.

    1998-05-01

    This report summarizes one of a series of EPRI- and National Rural Electric Cooperative Association (NRECA)-sponsored research efforts on vertical ground heat exchanger grout and grouting techniques as applied to geothermal heat pumps. In particular, this effort studied actual in-field installation issues for various grout mixtures and types of grouting equipment in different parts of the country.

  2. Geothermal R&D Program FY 1988 Project Summaries

    SciTech Connect (OSTI)

    1988-10-01

    This report summarizes DOE Geothermal R&D subprograms, major tasks, and projects. Contract funding amounts are shown. Many summaries have references (citations) to the researchers' previous related work. These can be useful. Geothermal budget actual amounts are shown for FY 1984 -1988. (DJE 2005)

  3. Evaluation of the Impact of EISA Federal Project Investments

    SciTech Connect (OSTI)

    Judd, Kathleen S.; Wendel, Emily M.; Morris, Scott L.; Williamson, Jennifer L.; Halverson, Mark A.; Livingston, Olga V.; Loper, Susan A.

    2012-12-31

    The DOE's Federal Energy Management Program has been charged by Office of Management and Budget to conduct an evaluation on actual and verifiable energy savings and carbon emissions reductions from federal energy management investments made across the Federal government as a result of the Energy Independence and Security Act of 2007. This study presents the findings from that evaluation.

  4. Empirically Derived Strength of Residential Roof Structures for Solar Installations.

    SciTech Connect (OSTI)

    Dwyer, Stephen F.; Sanchez, Alfred; Campos, Ivan A.; Gerstle, Walter H.

    2014-12-01

    Engineering certification for the installation of solar photovoltaic (PV) modules on wood roofs is often denied because existing wood roofs do not meet structural design codes. This work is intended to show that many roofs are actually sufficiently strong given the conservatism in codes, documented allowable strengths, roof structure system effects, and beam composite action produced by joist-sheathing interaction. This report provides results from a testing program to provide actual load carrying capacity of residential rooftops. The results reveal that the actual load carrying capacity of structural members and systems tested are significantly stronger than allowable loads provided by the International Residential Code (IRC 2009) and the national structural code found in Minimum Design Loads for Buildings and Other Structures (ASCE 7-10). Engineering analysis of residential rooftops typically ignores the system affects and beam composite action in determining rooftop stresses given a potential PV installation. This extreme conservatism combined with conservatism in codes and published allowable stress values for roof building materials (NDS 2012) lead to the perception that well built homes may not have adequate load bearing capacity to enable a rooftop PV installation. However, based on the test results presented in this report of residential rooftop structural systems, the actual load bearing capacity is several times higher than published values (NDS 2012).

  5. Farmer owned multi-use solar buildings for drying hay, grain, or heating shop

    SciTech Connect (OSTI)

    DeBusk, K.E.

    1983-06-01

    Identical multi-use solar buildings were built and tested on two farms in 1982. Actual (not simple) pay back periods are given for the two buildings for hay and for grain drying. Comparisons between solar and computed propane gas costs are reported.

  6. Women @ Energy: Renée Breyer

    Broader source: Energy.gov [DOE]

    "For female students to consider a STEM career, they need personal encouragement from instructors or counselors at an early age. In addition to hearing encouraging words from instructors and counselors, women need to see—in posters, videos and career events with women actually working in STEM disciplines—what a typical day looks like for women employed as technicians in STEM workplaces."

  7. The Mysterious Properties of Graphene

    Broader source: Energy.gov [DOE]

    Graphene, a sheet of carbon only a single atom thick, was an object of theoretical speculation long before it was actually made. Using the Advanced Light Source, researchers have taken a step towards confirming that graphene is every bit as unusual as expected – perhaps even more so.


  8. Requirements for transporting the TMI-2 core

    SciTech Connect (OSTI)

    Wilkins, D.E.

    1983-08-01

    This report summarizes the requirements associated with the actual transport of core debris from the damaged Three Mile Island Unit 2 reactor to the Idaho National Engineering Laboratory. The requirements are discussed under six headings: accountability, security, quality, safety, environment, and transportation.

  9. Test plan : reducing soft costs of rooftop solar installations attributed to structural considerations.

    SciTech Connect (OSTI)

    Dwyer, Stephen F.

    2013-05-01

    This test plan is a document that provides a systematic approach to the planned testing of rooftop structures to determine their actual load carrying capacity. This document identifies typical tests to be performed, the responsible parties for testing, the general feature of the tests, the testing approach, test deliverables, testing schedule, monitoring requirements, and environmental and safety compliance.

  10. CX-011805: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Carbon Dioxide Capture By Cold Membrane Operation with Actual Coal-Fired Power Plant Flue Gas CX(s) Applied: A1, A9, B3.6, B5.5 Date: 01/28/2014 Location(s): CX: none, Delaware, Alabama, Pennsylvania, California Offices(s): National Energy Technology Laboratory

  11. System for sensing droplet formation time delay in a flow cytometer

    DOE Patents [OSTI]

    Van den Engh, Ger (Seattle, WA); Esposito, Richard J. (Seattle, WA)

    1997-01-01

    A droplet flow cytometer system which includes a system to optimize the droplet formation time delay based on conditions actually experienced includes an automatic droplet sampler which rapidly moves a plurality of containers stepwise through the droplet stream while simultaneously adjusting the droplet time delay. Through the system sampling of an actual substance to be processed can be used to minimize the effect of the substances variations or the determination of which time delay is optimal. Analysis such as cell counting and the like may be conducted manually or automatically and input to a time delay adjustment which may then act with analysis equipment to revise the time delay estimate actually applied during processing. The automatic sampler can be controlled through a microprocessor and appropriate programming to bracket an initial droplet formation time delay estimate. When maximization counts through volume, weight, or other types of analysis exists in the containers, the increment may then be reduced for a more accurate ultimate setting. This may be accomplished while actually processing the sample without interruption.

  12. Energy Transition Initiative, Island Energy Snapshot - Bahamas (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2015-02-01

    This profile provides a snapshot of the electricity generation or reduction technologies, including solar hot water heating, available to the Commonwealth of the Bahamas - a country consisting of more than 700 islands, cays, and islets - of which only 30 are actually inhabited. Heating and transportation fuels are not addressed.

  13. Ideal light concentrators with reflector gaps

    DOE Patents [OSTI]

    Winston, Roland (Chicago, IL)

    1980-01-01

    A cylindrical or trough-like radiant energy concentration and collection device is provided. The device includes an energy absorber, a glazing enveloping the absorber and a reflective wall. The ideal contour of the reflective wall is determined with reference to a virtual absorber and not the actual absorber cross section.

  14. Reactive power compensating system

    DOE Patents [OSTI]

    Williams, Timothy J.; El-Sharkawi, Mohamed A.; Venkata, Subrahmanyam S.

    1987-01-01

    The reactive power of an induction machine is compensated by providing fixed capacitors on each phase line for the minimum compensation required, sensing the current on one line at the time its voltage crosses zero to determine the actual compensation required for each phase, and selecting switched capacitors on each line to provide the balance of the compensation required.

  15. Testing and evaluation of light ablation decontamination

    SciTech Connect (OSTI)

    Demmer, R.L.; Ferguson, R.L.

    1994-10-01

    This report details the testing and evaluation of light ablation decontamination. It details WINCO contracted research and application of light ablation efforts by Ames Laboratory. Tests were conducted with SIMCON (simulated contamination) coupons and REALCON (actual radioactive metal coupons) under controlled conditions to compare cleaning effectiveness, speed and application to plant process type equipment.

  16. Potential Next Steps for the New Orleans City Council Energy Efficiency Resolution

    Broader source: Energy.gov [DOE]

    This document is adapted from an actual February 2008 deliverable memo and report delivered by the National Renewable Energy Laboratory (NREL) to the City Council of New Orleans, the office of the Mayor of New Orleans, the Chairperson of the Citizen Stakeholders Group (New Orleans Energy Task Force) and the Department of Energy Project Officer in February of 2008.

  17. Geotechnical Analysis Report for July 2002 - June 2003

    SciTech Connect (OSTI)

    Washington TRU Solutions LLC

    2004-03-03

    This Geotechnical Analysis Report (GAR) presents and interprets the geotechnical data from the underground excavations at the Waste Isolation Pilot Plant (WIPP). The data, which are obtained as part of a regular monitoring program, are used to characterize conditions, to compare actual performance to the design assumptions, and to evaluate and forecast the performance of the underground excavations.

  18. Critical Question #8: When are Heat Pump Water Heaters the Best Solution?

    Broader source: Energy.gov [DOE]

    What do we know about actual performance compared to promised performance? What is the best way to manage the space conditioning impacts on a home? Is there an easy decision tree for deciding if this is the best solution for a particular home (Climate? Utility prices? Accessibility? Physical space constraints? Workforce?)?

  19. 2012 4th Qtr Follow-ups

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    full rights for a total of 40aMW for a revenue forecast of 2.7 million. Actual elections came in at 14-16 aMW and at a lower price the FY 2012 REC revenues came in at...

  20. Production of Gasoline and Diesel from Biomass via Fast Pyrolysis, Hydrotreating and Hydrocracking: 2012 State of Technology and Projections to 2017

    SciTech Connect (OSTI)

    Jones, Susanne B.; Snowden-Swan, Lesley J.

    2013-08-27

    This report summarizes the economic impact of the work performed at PNNL during FY12 to improve fast pyrolysis oil upgrading via hydrotreating. A comparison is made between the projected economic outcome and the actual results based on experimental data. Sustainability metrics are also included.

  1. Building America - Resources for Energy Efficient Homes

    SciTech Connect (OSTI)

    2012-04-19

    Building America publications help builders achieve whole-house energy savings in five major climate zones. Using the recommendation and process improvements outlined in the Best Practices Series handbooks, builders can re-engineer their designs to improve energy performance and quality. Case studies for new and existing homes provide results from actual projects.

  2. WATCHBOARD

    Energy Science and Technology Software Center (OSTI)

    2003-05-12

    WATCHBOARD displays emergency preparedness exercise data as events are projected to occur in time, according to the exercise design. The display of data permits exercise controllers to track the upcoming, current, and past events according to the exercise clock. The software permits real time input from controllers as to the actual time events occur.

  3. Decontamination and recovery of materials at nuclear facilites - operating history

    SciTech Connect (OSTI)

    Gillis, P.J. Jr.

    1994-12-31

    Non-Destructive Cleaning (NDC) Mobile CO{sub 2} Decontamination Facilities have more than 120 months of operational time conducting radioactive decontamination at Nuclear Power Stations and U.S. Department of Energy sites. During this time, we have compiled an extensive database on what has been decontaminated and the cost savings realized. The following are areas of interest: (1) how the CO{sub 2} decontamination process works; (2) how radioactive wastes are minimized and radioactive exposure to personnel is reduced with the use of the NDC Decontamination Facility; (3) how the self-contained Mobile Decontamination Facility works to provide adequate containment and control of the radioactive materials; (4) what kinds of items have been decontaminated, ranging from tools to underwater television cameras and from electric motors to lead shielding; (5) liquid radioactive waste volume reduction; (6) mixed-waste volume reduction; and (7) achievements in dose reduction to radiation levels that are as low as is reasonably achievable (ALARA) The design and operating features and performance of the Mobile Decontamination Facility, as well as the actual volumes of materials decontaminated, the decontamination factors achieved, the amounts and types of things that are free released, and the actual cost savings in all of these areas have been assessed. The data that was used is actual utility data and not the vendor`s data. All the experiences were from actual power plants.

  4. TUNL XIX. Annual report, January 1-December 31, 1980. [North Carolina State Univ. activities at TUNL

    SciTech Connect (OSTI)

    1980-12-31

    Research performed by North Carolina State University personnel at TUNL is highlighted in this report, which is actually the complete TUNL progress report for 1980. Studies in the areas of neutron cross sections, neutron polarization, radiative capture, atomic physics and development activities are included. One may expect completed projects to be reported in physics journals or conference proceedings. (RWR)

  5. Direct laser additive fabrication system with image feedback control

    DOE Patents [OSTI]

    Griffith, Michelle L.; Hofmeister, William H.; Knorovsky, Gerald A.; MacCallum, Danny O.; Schlienger, M. Eric; Smugeresky, John E.

    2002-01-01

    A closed-loop, feedback-controlled direct laser fabrication system is disclosed. The feedback refers to the actual growth conditions obtained by real-time analysis of thermal radiation images. The resulting system can fabricate components with severalfold improvement in dimensional tolerances and surface finish.

  6. Financing Turnkey Efficiency Solutions for Small Buildings and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... FY2012 FY2013 FY2014 Milestones & Deliverables (Actual) Q3 (Apr-Jun) Q4 (Jul-Sep) Q1 (Octt-Dec) Legend 19987 Summary Q2 (Jan-Mar) FY 2013 SBSP Financing Project: Months 1-3: ...

  7. Greater fuel diversity needed to meet growing US electricity demand

    SciTech Connect (OSTI)

    Burt, B.; Mullins, S.

    2008-01-15

    Electricity demand is growing in the USA. One way to manage the uncertainty is to diversity fuel sources. Fuel sources include coal, natural gas, nuclear and renewable energy sources. Tables show actual and planned generation projects by fuel types. 1 fig., 2 tabs.

  8. SRS Software Verification Pre Operational and Startup Test

    SciTech Connect (OSTI)

    HILL, L.F.

    2000-10-18

    This document defines testing for the software used to control the Sodium Removal System (SRS). The testing is conducted off-line from the. physical plant by using a simulator built-in to the software. This provides verification of proper software operation prior to performing the operational acceptance tests with the actual plant hardware.

  9. Building America Case Study: Low-Cost Evaluation of Energy Savings at the Community Scale, Fresno, California (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-10-01

    A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes (WCHH) based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the House Simulation Protocols (Hendron, Robert; Engebrecht, Cheryn (2010). Building America House Simulation Protocols. Golden, CO: National Renewable Energy Laboratory.). Builders face several key problems when implementing a whole-house systems integrated measures package (SIMP) from a single test house into multiple houses. Although a technical solution already may have been evaluated and validated in an individual test house, the potential exists for constructability failures at the community scale. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a SIMP and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

  10. Chicagoland Single-Family Housing Characterization

    SciTech Connect (OSTI)

    Spanier, J.; Scheu, R.; Brand, L.; Yang, J.

    2012-06-01

    In this report, the PARR team identifies housing characteristics and energy use for fifteen housing types in the Chicagoland (Cook County, Illinois) region and specifies measure packages that provide an optimum level of energy savings based on a BEopt analysis. The analysis is based on assessor data and actual energy consumption data on 432,605 houses representing approximately 30% of the population.

  11. EFM units monitor gas flow

    SciTech Connect (OSTI)

    Not Available

    1994-02-01

    This paper describes the radio-controlled pipeline monitoring system established by Transcontinental Gas Pipe Line Corp. which was designed to equip all its natural gas purchasing metering facilities with electronic flow measurement computers. The paper describes the actual radio equipment used and the features and reliability of the equipment.

  12. Countdown

    SciTech Connect (OSTI)

    Peterson, S.

    1994-12-31

    This article is a discussion of the Limerick-1 cycle 5 refueling outage. The target was to learn from the successes of the European operators and complete the refueling outage in less than 40 days. Actual outage duration was 35 days, and some of the techniques used to achieve this goal are discussed.

  13. Zonetool

    Energy Science and Technology Software Center (OSTI)

    2009-12-11

    zonetool is a utility for managing signed DNS zones and managing DNSSEC keys. It maintains the state of managed DNS zones and uses the BIND utilities to actually perform key generation, zone signing, and validation.DNS administrators will use zonetool to initially deploy and further maintain a signed DNS zone.

  14. Some aspects of steam-water flow simulation in geothermal wells

    SciTech Connect (OSTI)

    Shulyupin, Alexander N.

    1996-01-24

    Actual aspects of steam-water simulation in geothermal wells are considered: necessary quality of a simulator, flow regimes, mass conservation equation, momentum conservation equation, energy conservation equation and condition equations. Shortcomings of traditional hydraulic approach are noted. Main questions of simulator development by the hydraulic approach are considered. New possibilities of a simulation with the structure approach employment are noted.

  15. Hybrid Ground Source System Analysis and Tool Development

    Broader source: Energy.gov [DOE]

    Project objectives: 1. Compile filtered hourly data for three monitored hybrid installations. 2.Validate existing HyGCHP model. 3.Refine and enhance the HyGCHP model (usability / capability). 4. Demonstrate impact of actual hybrid installations. 5. Report lessons learned and impacts of HyGSHPs to design/engineering community.

  16. CITSS Project Plan | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    CITSS Project Plan CITSS Project Plan The Customer Information Technology Support System (CITSS) Training Plan, from an actual DOE Commercial Off-The-Shelf (COTS) software integration project, can be used as a template to facilitate the creation of the training plan for your particular project. PDF icon CITSS Project Plan More Documents & Publications CITSS Project Plan Software Configuration Management Plan Training Plan

  17. Left to Our Own Devices – Financing Efficiency for Small Business and Low-Income Families (2009 Environmental Defense Fund Report)

    Broader source: Energy.gov [DOE]

    There is a widely known gap between cost-effective behavior, consumption patterns and actual marketplace conditions. This engineering gap/efficiency gap is particularly the case for low-income households and small businesses, which tend to depend on older, inefficient equipment. This study identifies the limitations of current and potential of relatively new mechanisms for efficiency investment micro-financing.

  18. Microsoft Word - BPAOvergenerationReport Draft Final wmw bpa...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    aMW HLH; 5,560 aMW LLH 3. Regional loads were represented by actual loads for 2010, factoring in 0.9 percent projected load growth in 2011 and 1.2 percent load growth in 2012 as...

  19. Energy Evaluation of a New Construction Pilot Community: Fresno, California

    SciTech Connect (OSTI)

    Burdick, A.; Poerschke, A.; Rapport, A.; Wayne, M.

    2014-06-01

    A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes (WCHH) based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the House Simulation Protocols (Hendron, Robert; Engebrecht, Cheryn (2010). Building America House Simulation Protocols. Golden, CO: National Renewable Energy Laboratory). Builders face several key problems when implementing a whole-house systems integrated measures package (SIMP) from a single test house into multiple houses. Although a technical solution already may have been evaluated and validated in an individual test house, the potential exists for constructability failures at the community scale. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a SIMP and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

  20. Energy Evaluation of a New Construction Pilot Community: Fresno, California

    SciTech Connect (OSTI)

    Burdick, A.; Poerschke, A.; Rapport, A.; Wayne, M.

    2014-06-01

    A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the Building America House Simulation Protocols developed by NREL. Builders face several key problems when implementing a whole-house systems integrated measures package from a single test house into multiple houses. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a measures package and the actual utility usage in the houses at the community scale of production. Five occupants participated in this research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.